Sample records for identify airflow obstruction

  1. Genome-Wide Association Studies Identify CHRNA5/3 and HTR4 in the Development of Airflow Obstruction

    PubMed Central

    Shrine, Nick R. G.; Loehr, Laura R.; Zhao, Jing Hua; Manichaikul, Ani; Lopez, Lorna M.; Smith, Albert Vernon; Heckbert, Susan R.; Smolonska, Joanna; Tang, Wenbo; Loth, Daan W.; Curjuric, Ivan; Hui, Jennie; Latourelle, Jeanne C.; Henry, Amanda P.; Aldrich, Melinda; Bakke, Per; Beaty, Terri H.; Bentley, Amy R.; Borecki, Ingrid B.; Brusselle, Guy G.; Burkart, Kristin M.; Chen, Ting-hsu; Couper, David; Crapo, James D.; Davies, Gail; Dupuis, Josée; Franceschini, Nora; Gulsvik, Amund; Hancock, Dana B.; Harris, Tamara B.; Hofman, Albert; Imboden, Medea; James, Alan L.; Khaw, Kay-Tee; Lahousse, Lies; Launer, Lenore J.; Litonjua, Augusto; Liu, Yongmei; Lohman, Kurt K.; Lomas, David A.; Lumley, Thomas; Marciante, Kristin D.; McArdle, Wendy L.; Meibohm, Bernd; Morrison, Alanna C.; Musk, Arthur W.; Myers, Richard H.; North, Kari E.; Postma, Dirkje S.; Psaty, Bruce M.; Rich, Stephen S.; Rivadeneira, Fernando; Rochat, Thierry; Rotter, Jerome I.; Artigas, María Soler; Starr, John M.; Uitterlinden, André G.; Wareham, Nicholas J.; Wijmenga, Cisca; Zanen, Pieter; Province, Michael A.; Silverman, Edwin K.; Deary, Ian J.; Palmer, Lyle J.; Cassano, Patricia A.; Gudnason, Vilmundur; Barr, R. Graham; Loos, Ruth J. F.; Strachan, David P.; London, Stephanie J.; Boezen, H. Marike; Probst-Hensch, Nicole; Gharib, Sina A.; Hall, Ian P.; O’Connor, George T.; Tobin, Martin D.; Stricker, Bruno H.

    2012-01-01

    Rationale: Genome-wide association studies (GWAS) have identified loci influencing lung function, but fewer genes influencing chronic obstructive pulmonary disease (COPD) are known. Objectives: Perform meta-analyses of GWAS for airflow obstruction, a key pathophysiologic characteristic of COPD assessed by spirometry, in population-based cohorts examining all participants, ever smokers, never smokers, asthma-free participants, and more severe cases. Methods: Fifteen cohorts were studied for discovery (3,368 affected; 29,507 unaffected), and a population-based family study and a meta-analysis of case-control studies were used for replication and regional follow-up (3,837 cases; 4,479 control subjects). Airflow obstruction was defined as FEV1 and its ratio to FVC (FEV1/FVC) both less than their respective lower limits of normal as determined by published reference equations. Measurements and Main Results: The discovery meta-analyses identified one region on chromosome 15q25.1 meeting genome-wide significance in ever smokers that includes AGPHD1, IREB2, and CHRNA5/CHRNA3 genes. The region was also modestly associated among never smokers. Gene expression studies confirmed the presence of CHRNA5/3 in lung, airway smooth muscle, and bronchial epithelial cells. A single-nucleotide polymorphism in HTR4, a gene previously related to FEV1/FVC, achieved genome-wide statistical significance in combined meta-analysis. Top single-nucleotide polymorphisms in ADAM19, RARB, PPAP2B, and ADAMTS19 were nominally replicated in the COPD meta-analysis. Conclusions: These results suggest an important role for the CHRNA5/3 region as a genetic risk factor for airflow obstruction that may be independent of smoking and implicate the HTR4 gene in the etiology of airflow obstruction. PMID:22837378

  2. Airflow obstruction, atherosclerosis and cardiovascular risk factors in the AGES Reykjavik study.

    PubMed

    Gudmundsson, Gunnar; Margretardottir, Olof Birna; Sigurdsson, Martin Ingi; Harris, Tamara B; Launer, Lenore J; Sigurdsson, Sigurdur; Olafsson, Orn; Aspelund, Thor; Gudnason, Vilmundur

    2016-09-01

    Airflow limitation, i.e. reduced forced expiratory volume in 1-s (FEV1), is associated with increased prevalence of atherosclerosis, however, causal mechanisms remain elusive. The objective of the study was to determine if the association between airflow obstruction and markers of atherosclerosis is mediated by systemic inflammation. 1154 subjects from the longitudinal AGES Reykjavik study were included. Population characteristics, systemic inflammation markers from blood (white blood cell counts (WBC) and level of C-reactive protein (CRP)) were compared between patients with and without airflow limitation defined by reduced FEV1 on spirometry. Atherosclerosis burden was quantified by measurements of coronary artery calcium, aortic arch and distal aortic calcification in addition to carotid intimal media thickness (CIMT). Subjects were split into four groups according to smoking status and whether airflow limitation was present. There was a higher overall burden of atherosclerosis in ever-smokers compared to never-smokers, and in individuals with airflow obstruction compared to individuals without airflow obstruction. After adjusting for population characteristics, Framingham cardiovascular risk factors and markers of systemic inflammation (WBC and CRP), there was a significantly increased aortic arch and distal aorta calcification and higher CIMT measurement in individuals with airflow obstruction compared to individuals without airflow obstruction. After adjusting for population characteristics, Framingham cardiovascular risk factors and markers of systemic inflammation (WBC and CRP), there was a significantly increased aortic arch and distal aorta calcification and higher CIMT measurement in individuals with airflow obstruction compared to individuals without airflow obstruction. Systemic inflammation (WBC and CRP) does not appear to mediate the association between airflow limitation and atherosclerosis. Only airflow limitation and not systemic inflammation (WBC

  3. Air trapping and airflow obstruction in newborn cystic fibrosis piglets.

    PubMed

    Adam, Ryan J; Michalski, Andrew S; Bauer, Christian; Abou Alaiwa, Mahmoud H; Gross, Thomas J; Awadalla, Maged S; Bouzek, Drake C; Gansemer, Nicholas D; Taft, Peter J; Hoegger, Mark J; Diwakar, Amit; Ochs, Matthias; Reinhardt, Joseph M; Hoffman, Eric A; Beichel, Reinhard R; Meyerholz, David K; Stoltz, David A

    2013-12-15

    Air trapping and airflow obstruction are being increasingly identified in infants with cystic fibrosis. These findings are commonly attributed to airway infection, inflammation, and mucus buildup. To learn if air trapping and airflow obstruction are present before the onset of airway infection and inflammation in cystic fibrosis. On the day they are born, piglets with cystic fibrosis lack airway infection and inflammation. Therefore, we used newborn wild-type piglets and piglets with cystic fibrosis to assess air trapping, airway size, and lung volume with inspiratory and expiratory X-ray computed tomography scans. Micro-computed tomography scanning was used to assess more distal airway sizes. Airway resistance was determined with a mechanical ventilator. Mean linear intercept and alveolar surface area were determined using stereologic methods. On the day they were born, piglets with cystic fibrosis exhibited air trapping more frequently than wild-type piglets (75% vs. 12.5%, respectively). Moreover, newborn piglets with cystic fibrosis had increased airway resistance that was accompanied by luminal size reduction in the trachea, mainstem bronchi, and proximal airways. In contrast, mean linear intercept length, alveolar surface area, and lung volume were similar between both genotypes. The presence of air trapping, airflow obstruction, and airway size reduction in newborn piglets with cystic fibrosis before the onset of airway infection, inflammation, and mucus accumulation indicates that cystic fibrosis impacts airway development. Our findings suggest that early airflow obstruction and air trapping in infants with cystic fibrosis might, in part, be caused by congenital airway abnormalities.

  4. Tuberculosis associates with both airflow obstruction and low lung function: BOLD results.

    PubMed

    Amaral, André F S; Coton, Sonia; Kato, Bernet; Tan, Wan C; Studnicka, Michael; Janson, Christer; Gislason, Thorarinn; Mannino, David; Bateman, Eric D; Buist, Sonia; Burney, Peter G J

    2015-10-01

    In small studies and cases series, a history of tuberculosis has been associated with both airflow obstruction, which is characteristic of chronic obstructive pulmonary disease, and restrictive patterns on spirometry. The objective of the present study was to assess the association between a history of tuberculosis and airflow obstruction and spirometric abnormalities in adults.The study was performed in adults, aged 40 years and above, who took part in the multicentre, cross-sectional, general population-based Burden of Obstructive Lung Disease study, and had provided acceptable post-bronchodilator spirometry measurements and information on a history of tuberculosis. The associations between a history of tuberculosis and airflow obstruction and spirometric restriction were assessed within each participating centre, and estimates combined using meta-analysis. These estimates were stratified by high- and low/middle-income countries, according to gross national income.A self-reported history of tuberculosis was associated with airflow obstruction (adjusted odds ratio 2.51, 95% CI 1.83-3.42) and spirometric restriction (adjusted odds ratio 2.13, 95% CI 1.42-3.19).A history of tuberculosis was associated with both airflow obstruction and spirometric restriction, and should be considered as a potentially important cause of obstructive disease and low lung function, particularly where tuberculosis is common. Copyright ©ERS 2015.

  5. Tuberculosis associates with both airflow obstruction and low lung function: BOLD results

    PubMed Central

    Amaral, André F. S.; Coton, Sonia; Kato, Bernet; Tan, Wan C.; Studnicka, Michael; Janson, Christer; Gislason, Thorarinn; Mannino, David; Bateman, Eric D.; Buist, Sonia; Burney, Peter G. J.

    2015-01-01

    Background In small studies and cases series, a history of tuberculosis has been associated with both airflow obstruction, which is characteristic of chronic obstructive pulmonary disease, and restrictive patterns on spirometry. Objective To assess the association between a history of tuberculosis and airflow obstruction and spirometric abnormalities in adults. Methods The study was performed in adults, aged 40 and above, who took part in the multicentre cross-sectional, general population-based, Burden of Obstructive Lung Disease study, had provided acceptable post-bronchodilator spirometry measurements and information on a history of tuberculosis. The associations between a history of tuberculosis and airflow obstruction and spirometric restriction were assessed within each participating centre, and estimates combined using meta-analysis. These estimates were stratified by high and low/middle income countries, according to gross national income. Results A self-reported history of tuberculosis was associated with airflow obstruction (adjusted odds ratio = 2.51, 95% confidence interval 1.83-3.42) and spirometric restriction (adjusted odds ratio = 2.13, 95% confidence interval 1.42-3.19). Conclusion A history of tuberculosis was associated with both airflow obstruction and spirometric restriction, and should be considered as a potentially important cause of obstructive disease and low lung function, particularly where tuberculosis is common. PMID:26113680

  6. Validity of peak expiratory flow measurement in assessing reversibility of airflow obstruction.

    PubMed Central

    Dekker, F W; Schrier, A C; Sterk, P J; Dijkman, J H

    1992-01-01

    BACKGROUND: Assessing the reversibility of airflow obstruction by peak expiratory (PEF) measurements would be practicable in general practice, but its usefulness has not been investigated. METHODS: PEF measurements were performed (miniWright peak flow meter) in 73 general practice patients (aged 40 to 84) with a history of asthma or chronic obstructive lung disease before and after 400 micrograms inhaled sulbutamol. The change in PEF was compared with the change in forced expiratory volume in one second (FEV1). Reversible airflow obstruction was analysed in two ways according to previous criteria. When defined as a 9% or greater increase in FEV1 expressed as a percentage of predicted values reversibility was observed in 42% of patients. Relative operating characteristic analysis showed that an absolute improvement in PEF of 60 l/min or more gave optimal discrimination between patients with reversible and irreversible airflow obstruction (the sensitivity and specificity of an increase of 60 l/min in detecting a 9% or more increase in FEV1 as a percentage of predicted values were 68% and 93% respectively, with a positive predictive value of 87%). When defined as an increase of 190 ml or more in FEV1, reversible airflow obstruction was observed in 53% of patients. Again an absolute improvement in PEF of 60 l/min or more gave optimal discrimination between patients with reversible and irreversible airflow obstruction (sensitivity 56%, specificity 94%, and positive predictive value 92%). CONCLUSION: Absolute changes in PEF can be used as a simple technique to diagnose reversible airflow obstruction in patients from general practice. PMID:1519192

  7. Inflammatory Biomarkers Predict Airflow Obstruction After Exposure to World Trade Center Dust

    PubMed Central

    Nolan, Anna; Naveed, Bushra; Comfort, Ashley L.; Ferrier, Natalia; Hall, Charles B.; Kwon, Sophia; Kasturiarachchi, Kusali J.; Cohen, Hillel W.; Zeig-Owens, Rachel; Glaser, Michelle S.; Webber, Mayris P.; Aldrich, Thomas K.; Rom, William N.; Kelly, Kerry; Prezant, David J.

    2012-01-01

    Background: The World Trade Center (WTC) collapse on September 11, 2001, produced airflow obstruction in a majority of firefighters receiving subspecialty pulmonary evaluation (SPE) within 6.5 years post-September 11, 2001. Methods: In a cohort of 801 never smokers with normal pre-September 11, 2001, FEV1, we correlated inflammatory biomarkers and CBC counts at monitoring entry within 6 months of September 11, 2001, with a median FEV1 at SPE (34 months; interquartile range, 25-57). Cases of airflow obstruction had FEV1 less than the lower limit of normal (LLN) (100 of 801; 70 of 100 had serum), whereas control subjects had FEV1 greater than or equal to LLN (153 of 801; 124 of 153 had serum). Results: From monitoring entry to SPE years later, FEV1 declined 12% in cases and increased 3% in control subjects. Case subjects had elevated serum macrophage derived chemokine (MDC), granulocyte-macrophage colony-stimulating factor (GM-CSF), granulocyte colony-stimulating factor, and interferon inducible protein-10 levels. Elevated GM-CSF and MDC increased the risk for subsequent FEV1 less than LLN by 2.5-fold (95% CI, 1.2-5.3) and 3.0-fold (95% CI, 1.4-6.1) in a logistic model adjusted for exposure, BMI, age on September 11, 2001, and polymorphonuclear neutrophils. The model had sensitivity of 38% (95% CI, 27-51) and specificity of 88% (95% CI, 80-93). Conclusions: Inflammatory biomarkers can be risk factors for airflow obstruction following dust and smoke exposure. Elevated serum GM-CSF and MDC levels soon after WTC exposure were associated with increased risk of airflow obstruction in subsequent years. Biomarkers of inflammation may help identify pathways producing obstruction after irritant exposure. PMID:21998260

  8. Proportion and clinical characteristics of non-asthmatic non-smokers among adults with airflow obstruction.

    PubMed

    Takiguchi, Hiroto; Takeuchi, Tomoe; Niimi, Kyoko; Tomomatsu, Hiromi; Tomomatsu, Katsuyoshi; Hayama, Naoki; Oguma, Tsuyoshi; Aoki, Takuya; Urano, Tetsuya; Asai, Satomi; Miyachi, Hayato; Asano, Koichiro

    2018-01-01

    Chronic obstructive pulmonary disease (COPD) mainly develops after long-term exposure to cigarette or biomass fuel smoke, but also occurs in non-smokers with or without a history of asthma. We investigated the proportion and clinical characteristics of non-smokers among middle-aged to elderly subjects with airflow obstruction. We retrospectively analyzed 1,892 subjects aged 40-89 years who underwent routine preoperative spirometry at a tertiary university hospital in Japan. Airflow obstruction was defined as a forced expiratory volume in 1 second (FEV1)/forced vital capacity < 0.7 or as the lower limit of the normal. Among 323 patients presenting with FEV1/forced vital capacity < 0.7, 43 had asthma and 280 did not. Among the non-asthmatic patients with airflow obstruction, 94 (34%) were non-smokers. A larger number of women than men with airflow obstruction had asthma (26% vs. 7.6%, p < 0.001), or were non-smokers among non-asthmatics (72% vs. 20%, p < 0.001). Non-asthmatic non-smokers, rather than non-asthmatic smokers, asthmatic non-smokers, and asthmatic smokers, exhibited better pulmonary function (median FEV1: 79% of predicted FEV1 vs. 73%, 69%, and 66%, respectively, p = 0.005) and less dyspnea on exertion (1% vs. 12%, 12%, and 28%, respectively, p = 0.001). Pulmonary emphysema on thoracic computed tomography was less common in non-smokers (p < 0.001). Using the lower limit of the normal to define airflow obstruction yielded similar results. There are a substantial number of non-smokers with airflow obstruction compatible with COPD in Japan. In this study, airflow obstruction in non-smokers was more common in women and likelier to result in mild functional and pathological abnormalities than in smokers. Further studies are warranted to investigate the long-term prognosis and appropriate management of this population in developed countries, especially in women.

  9. Proportion and clinical characteristics of non-asthmatic non-smokers among adults with airflow obstruction

    PubMed Central

    Takiguchi, Hiroto; Takeuchi, Tomoe; Niimi, Kyoko; Tomomatsu, Hiromi; Tomomatsu, Katsuyoshi; Hayama, Naoki; Oguma, Tsuyoshi; Urano, Tetsuya; Asai, Satomi; Miyachi, Hayato; Asano, Koichiro

    2018-01-01

    Background and objectives Chronic obstructive pulmonary disease (COPD) mainly develops after long-term exposure to cigarette or biomass fuel smoke, but also occurs in non-smokers with or without a history of asthma. We investigated the proportion and clinical characteristics of non-smokers among middle-aged to elderly subjects with airflow obstruction. Methods We retrospectively analyzed 1,892 subjects aged 40–89 years who underwent routine preoperative spirometry at a tertiary university hospital in Japan. Airflow obstruction was defined as a forced expiratory volume in 1 second (FEV1)/forced vital capacity < 0.7 or as the lower limit of the normal. Results Among 323 patients presenting with FEV1/forced vital capacity < 0.7, 43 had asthma and 280 did not. Among the non-asthmatic patients with airflow obstruction, 94 (34%) were non-smokers. A larger number of women than men with airflow obstruction had asthma (26% vs. 7.6%, p < 0.001), or were non-smokers among non-asthmatics (72% vs. 20%, p < 0.001). Non-asthmatic non-smokers, rather than non-asthmatic smokers, asthmatic non-smokers, and asthmatic smokers, exhibited better pulmonary function (median FEV1: 79% of predicted FEV1 vs. 73%, 69%, and 66%, respectively, p = 0.005) and less dyspnea on exertion (1% vs. 12%, 12%, and 28%, respectively, p = 0.001). Pulmonary emphysema on thoracic computed tomography was less common in non-smokers (p < 0.001). Using the lower limit of the normal to define airflow obstruction yielded similar results. Conclusions There are a substantial number of non-smokers with airflow obstruction compatible with COPD in Japan. In this study, airflow obstruction in non-smokers was more common in women and likelier to result in mild functional and pathological abnormalities than in smokers. Further studies are warranted to investigate the long-term prognosis and appropriate management of this population in developed countries, especially in women. PMID:29742176

  10. Difference in airflow obstruction between Hispanic and non-Hispanic White female smokers.

    PubMed

    Sood, Akshay; Stidley, Christine A; Picchi, Maria A; Celedón, Juan C; Gilliland, Frank; Crowell, Richard E; Belinsky, Steven A; Tesfaigzi, Yohannes

    2008-10-01

    Smoking-related respiratory diseases are a major cause of morbidity and mortality. However, the relationship between smoking and respiratory disease has not been well-studied among ethnic minorities in general and among women in particular. The objective of this cross-sectional study was to evaluate the risk of airflow obstruction and to assess lung function among Hispanic and non-Hispanic White (NHW) female smokers in a New Mexico cohort. Participants completed a questionnaire detailing smoking history and underwent spirometry testing. Outcomes studied included airflow obstruction, selected lung function parameters, and chronic mucus hyper-secretion. Chi square, logistic, and linear regression techniques were utilized. Of the 1,433 eligible women participants, 248 (17.3%) were Hispanic; and 319 had airflow obstruction (22.3%). Hispanic smokers were more likely to be current smokers, and report lower pack-years of smoking, compared to NHW smokers (p < 0.05 for all analyses). Further, Hispanic smokers were at a reduced risk of airflow obstruction compared to NHW smokers, with an O.R. of 0.51, 95% C.I. 0.34, 0.78 (p = 0.002) after adjustment for age, BMI, pack-years and duration of smoking, and current smoking status. Following adjustment for covariates, Hispanic smokers also had a higher mean absolute and percent predicted post-bronchodilator FEV(1)/FVC ratio, as well as higher mean percent predicted FEV(1) (p < 0.05 for all analyses). Hispanic female smokers in this New Mexico-based cohort had lower risk of airflow obstruction and better lung function than NHW female smokers. Further, smoking history did not completely explain these associations.

  11. A computational study of the respiratory airflow characteristics in normal and obstructed human airways.

    PubMed

    Sul, Bora; Wallqvist, Anders; Morris, Michael J; Reifman, Jaques; Rakesh, Vineet

    2014-09-01

    Obstructive lung diseases in the lower airways are a leading health concern worldwide. To improve our understanding of the pathophysiology of lower airways, we studied airflow characteristics in the lung between the 8th and the 14th generations using a three-dimensional computational fluid dynamics model, where we compared normal and obstructed airways for a range of breathing conditions. We employed a novel technique based on computing the Pearson׳s correlation coefficient to quantitatively characterize the differences in airflow patterns between the normal and obstructed airways. We found that the airflow patterns demonstrated clear differences between normal and diseased conditions for high expiratory flow rates (>2300ml/s), but not for inspiratory flow rates. Moreover, airflow patterns subjected to filtering demonstrated higher sensitivity than airway resistance for differentiating normal and diseased conditions. Further, we showed that wall shear stresses were not only dependent on breathing rates, but also on the distribution of the obstructed sites in the lung: for the same degree of obstruction and breathing rate, we observed as much as two-fold differences in shear stresses. In contrast to previous studies that suggest increased wall shear stress due to obstructions as a possible damage mechanism for small airways, our model demonstrated that for flow rates corresponding to heavy activities, the wall shear stress in both normal and obstructed airways was <0.3Pa, which is within the physiological limit needed to promote respiratory defense mechanisms. In summary, our model enables the study of airflow characteristics that may be impractical to assess experimentally. Published by Elsevier Ltd.

  12. Scoliosis associated with airflow obstruction due to endothoracic vertebral hump.

    PubMed

    Ito, Kenyu; Kawakami, Noriaki; Miyasaka, Kazuyoshi; Tsuji, Taichi; Ohara, Tetsuya; Nohara, Ayato

    2012-12-01

    A retrospective clinical study of scoliosis-associated airflow obstruction due to endothoracic vertebral hump. The purpose of this study was to evaluate and present anatomical features of patients with scoliosis who showed airflow obstruction caused by endothoracic vertebral hump. It is well known that severe scoliosis causes airflow restriction due to thoracic cage deformity. There have been few reports of clinical data and anatomical features on scoliosis associated with airflow obstruction due to endothoracic vertebral hump. The subjects were 6 patients. The diagnoses were idiopathic scoliosis in 3 patients, symptomatic scoliosis in 2 patients, and thoracogenic scoliosis in 1 patient. The radiological outcome, comorbidities, pre- and postoperative respiratory function, and surgical complication were analyzed. Four patients had preoperative atelectasis on the convex side of the lower lobe and improved after the operations. All patients showed main thoracic curves and their apex was located at T7-T9. All patients had lordoscoliosis except 1, who demonstrated kyphosing scoliosis. The correction rate was 78% (62.8%-83.5%). Preoperative thoracic lordosis within the range of -5° to -47° was postoperatively corrected to a substantially normal kyphosis within the range of 9° to 24°. The average vital capacity, percent VC improved from 0.72 L (0.33-1.17 L) to 1.21 L (0.82-1.71 L) and 45.5% (37.3%- 50.8%) to 63.7% (41.0%-88.6%) relatively. Spine Penetration Index improved from 23% (18%-35%) to 16% (13%-19%). Endothoracic hump ratio improved from 1.34 (0.98-1.93) to 1.12 (0.86-1.28). Each patient with symptomatic scoliosis and thoracogenic scoliosis required relatively long periods of respiration management. Patients having lordoscoliosis with an apex located between T7 and T9 may develop airflow obstruction due to an endothoracic vertebral hump. Correction of lordoscoliosis through anterior and posterior approaches successfully improved endothoracic hump ratio and

  13. Clinically remitted childhood asthma is associated with airflow obstruction in middle-aged adults.

    PubMed

    Omori, Keitaro; Iwamoto, Hiroshi; Yamane, Takashi; Nakashima, Taku; Haruta, Yoshinori; Hattori, Noboru; Yokoyama, Akihito; Kohno, Nobuoki

    2017-01-01

    While adult asthma has been shown to be a risk factor for COPD, the effect of remitted childhood asthma on adult lung function has not been clarified. The aim of this study was to examine whether remitted childhood asthma is a risk factor for airflow obstruction in a middle-aged general population. A total of 9896 participants (range: 35-60 years) from five healthcare centres were included in the study. The participants were classified into four categories based on the presence or absence of physician-diagnosed childhood/adulthood asthma and asthma symptoms as follows: healthy controls (n = 9154), remitted childhood asthma (n = 287), adulthood-onset asthma (n = 354) and childhood-adulthood asthma (n = 101). The prevalence of respiratory symptoms was similar in both the participants with remitted childhood asthma and healthy controls. The prevalence of airflow obstruction (forced expiratory volume in 1 s (FEV 1 )/forced vital capacity (FVC) < 0.7) was significantly higher in the participants with remitted childhood asthma, those with adult-onset asthma and those with childhood-adulthood asthma (5.2%, 14.4% and 16.8%, respectively) compared with healthy controls (2.2%). Multivariate logistic regression showed that remitted childhood asthma was independently associated with airflow obstruction. Among the participants with remitted childhood asthma, ever-smokers had significantly lower FEV 1 /FVC than never-smokers. Clinically remitted childhood asthma is associated with airflow obstruction in middle-aged adults. Smoking and remitted childhood asthma may be additive factors for the development of airflow obstruction. © 2016 Asian Pacific Society of Respirology.

  14. FEV1/FVC and FEV1 for the assessment of chronic airflow obstruction in prevalence studies: do prediction equations need revision?

    PubMed

    Roche, Nicolas; Dalmay, François; Perez, Thierry; Kuntz, Claude; Vergnenègre, Alain; Neukirch, Françoise; Giordanella, Jean-Pierre; Huchon, Gérard

    2008-11-01

    Little is known on the long-term validity of reference equations used in the calculation of FEV(1) and FEV(1)/FVC predicted values. This survey assessed the prevalence of chronic airflow obstruction in a population-based sample and how it is influenced by: (i) the definition of airflow obstruction; and (ii) equations used to calculate predicted values. Subjects aged 45 or more were recruited in health prevention centers, performed spirometry and fulfilled a standardized ECRHS-derived questionnaire. Previously diagnosed cases and risk factors were identified. Prevalence of airflow obstruction was calculated using: (i) ATS-GOLD definition (FEV(1)/FVC<0.70); and (ii) ERS definition (FEV(1)/FVCairflow obstruction was 8.71% with ATS-GOLD definition and 6.40% with ERS definition and ECCS predicted values. The ERS definition with predicted values derived from the studied population provided a 7.96% prevalence. Severity distribution of airflow obstruction was also influenced by the equation used to calculate predicted values of FEV(1). Prevalence and severity of chronic airflow obstruction are influenced not only by the definition used but also by equations used to calculate predicted FEV(1)/FVC and FEV(1) values. These equations likely need to be periodically revised.

  15. Changes in nasal airflow and heat transfer correlate with symptom improvement after surgery for nasal obstruction.

    PubMed

    Kimbell, J S; Frank, D O; Laud, Purushottam; Garcia, G J M; Rhee, J S

    2013-10-18

    Surgeries to correct nasal airway obstruction (NAO) often have less than desirable outcomes, partly due to the absence of an objective tool to select the most appropriate surgical approach for each patient. Computational fluid dynamics (CFD) models can be used to investigate nasal airflow, but variables need to be identified that can detect surgical changes and correlate with patient symptoms. CFD models were constructed from pre- and post-surgery computed tomography scans for 10 NAO patients showing no evidence of nasal cycling. Steady-state inspiratory airflow, nasal resistance, wall shear stress, and heat flux were computed for the main nasal cavity from nostrils to posterior nasal septum both bilaterally and unilaterally. Paired t-tests indicated that all CFD variables were significantly changed by surgery when calculated on the most obstructed side, and that airflow, nasal resistance, and heat flux were significantly changed bilaterally as well. Moderate linear correlations with patient-reported symptoms were found for airflow, heat flux, unilateral allocation of airflow, and unilateral nasal resistance as a fraction of bilateral nasal resistance when calculated on the most obstructed nasal side, suggesting that these variables may be useful for evaluating the efficacy of nasal surgery objectively. Similarity in the strengths of these correlations suggests that patient-reported symptoms may represent a constellation of effects and that these variables should be tracked concurrently during future virtual surgery planning. © 2013 Elsevier Ltd. All rights reserved.

  16. A comparison of five surveys that identify individuals at risk for airflow obstruction and chronic obstructive pulmonary disease.

    PubMed

    Sogbetun, Folarin; Eschenbacher, William L; Welge, Jeffrey A; Panos, Ralph J

    2016-11-01

    The predictive characteristics of different screening surveys for the recognition of individuals at risk for airflow obstruction (AFO) have not been evaluated simultaneously in the same population. To compare five AFO/COPD screening questionnaires. 383 individuals completed the Veterans Airflow Obstruction Screening Questionnaire, Personal Level Screener for COPD (VAFOSQ), the 11-Q COPD Screening Questionnaire (11-Q), the COPD Population Screener (COPD-PS) and the Lung Function Questionnaire (LFQ) and performed spirometry. AFO was defined as forced expiratory volume in one second divided by the forced vital capacity (FEV 1 /FVC) < 0.7, fixed ratio (FR) or FEV 1 /FVC < lower limit of normal (LLN). The predictive characteristics of the five questionnaires were calculated and non-parametric receiver operating characteristic (ROC) curves estimated by logistic regression. 376 participants completed at least two of the questionnaires and performed technically acceptable spirometry. AFO was present in 102 (27.1%) and 150 (39.9%) based on LLN and FR, respectively. The number of individuals positively selected by the VAFOSQ was 227, PLS 128, 11-Q 236, COPD-PS 217, and LFQ 328. The area under the ROC curves for the questionnaires was between 0.60 and 0.66 (LLN) and 0.58 and 0.66 (FR). Although these screening surveys have acceptable and similar predictive ability for the identification of AFO, their published thresholds lead to substantially different classification rates. The choice of an appropriate threshold for the identification of individuals with possible AFO/COPD should consider the underlying prevalence of AFO/COPD in the target population and the relative costs of misclassifying affected and unaffected cases. None. Veterans Health Administration. Published by Elsevier Ltd.

  17. Computational fluid dynamics (CFD) investigation of impacts of an obstruction on airflow in underground mines.

    PubMed

    Zhou, L; Goodman, G; Martikainen, A

    2013-01-01

    Continuous airflow monitoring can improve the safety of the underground work force by ensuring the uninterrupted and controlled distribution of mine ventilation to all working areas. Air velocity measurements vary significantly and can change rapidly depending on the exact measurement location and, in particular, due to the presence of obstructions in the air stream. Air velocity must be measured at locations away from obstructions to avoid the vortices and eddies that can produce inaccurate readings. Further, an uninterrupted measurement path cannot always be guaranteed when using continuous airflow monitors due to the presence of nearby equipment, personnel, roof falls and rib rolls. Effective use of these devices requires selection of a minimum distance from an obstacle, such that an air velocity measurement can be made but not affected by the presence of that obstacle. This paper investigates the impacts of an obstruction on the behavior of downstream airflow using a numerical CFD model calibrated with experimental test results from underground testing. Factors including entry size, obstruction size and the inlet or incident velocity are examined for their effects on the distributions of airflow around an obstruction. A relationship is developed between the minimum measurement distance and the hydraulic diameters of the entry and the obstruction. A final analysis considers the impacts of continuous monitor location on the accuracy of velocity measurements and on the application of minimum measurement distance guidelines.

  18. Determinants of airflow obstruction in severe alpha‐1‐antitrypsin deficiency

    PubMed Central

    DeMeo, Dawn L; Sandhaus, Robert A; Barker, Alan F; Brantly, Mark L; Eden, Edward; McElvaney, N Gerard; Rennard, Stephen; Burchard, Esteban; Stocks, James M; Stoller, James K; Strange, Charlie; Turino, Gerard M; Campbell, Edward J; Silverman, Edwin K

    2007-01-01

    Background Severe α1‐antitrypsin (AAT) deficiency is an autosomal recessive genetic condition associated with an increased but variable risk for chronic obstructive pulmonary disease (COPD). A study was undertaken to assess the impact of chronic bronchitis, pneumonia, asthma and sex on the development of COPD in individuals with severe AAT deficiency. Methods The AAT Genetic Modifier Study is a multicentre family‐based cohort study designed to study the genetic and epidemiological determinants of COPD in AAT deficiency. 378 individuals (age range 33–80 years), confirmed to be homozygous for the SERPINA1 Z mutation, were included in the analyses. The primary outcomes of interest were a quantitative outcome, forced expiratory volume in 1 s (FEV1) percentage predicted, and a qualitative outcome, severe airflow obstruction (FEV1 <50% predicted). Results In multivariate analysis of the overall cohort, cigarette smoking, sex, asthma, chronic bronchitis and pneumonia were risk factors for reduced FEV1 percentage predicted and severe airflow obstruction (p<0.01). Index cases had lower FEV1 values, higher smoking histories and more reports of adult asthma, pneumonia and asthma before age 16 than non‐index cases (p<0.01). Men had lower pre‐ and post‐bronchodilator FEV1 percentage predicted than women (p<0.0001); the lowest FEV1 values were observed in men reporting a history of childhood asthma (26.9%). This trend for more severe obstruction in men remained when index and non‐index groups were examined separately, with men representing the majority of non‐index individuals with airflow obstruction (71%). Chronic bronchitis (OR 3.8, CI 1.8 to 12.0) and a physician's report of asthma (OR 4.2, CI 1.4 to 13.1) were predictors of severe airflow obstruction in multivariate analysis of non‐index men but not women. Conclusion In individuals with severe AAT deficiency, sex, asthma, chronic bronchitis and pneumonia are risk factors for severe COPD, in addition

  19. Computational fluid dynamics (CFD) investigation of impacts of an obstruction on airflow in underground mines

    PubMed Central

    Zhou, L.; Goodman, G.; Martikainen, A.

    2015-01-01

    Continuous airflow monitoring can improve the safety of the underground work force by ensuring the uninterrupted and controlled distribution of mine ventilation to all working areas. Air velocity measurements vary significantly and can change rapidly depending on the exact measurement location and, in particular, due to the presence of obstructions in the air stream. Air velocity must be measured at locations away from obstructions to avoid the vortices and eddies that can produce inaccurate readings. Further, an uninterrupted measurement path cannot always be guaranteed when using continuous airflow monitors due to the presence of nearby equipment, personnel, roof falls and rib rolls. Effective use of these devices requires selection of a minimum distance from an obstacle, such that an air velocity measurement can be made but not affected by the presence of that obstacle. This paper investigates the impacts of an obstruction on the behavior of downstream airflow using a numerical CFD model calibrated with experimental test results from underground testing. Factors including entry size, obstruction size and the inlet or incident velocity are examined for their effects on the distributions of airflow around an obstruction. A relationship is developed between the minimum measurement distance and the hydraulic diameters of the entry and the obstruction. A final analysis considers the impacts of continuous monitor location on the accuracy of velocity measurements and on the application of minimum measurement distance guidelines. PMID:26388684

  20. Childhood-Onset Asthma in Smokers. Association between CT Measures of Airway Size, Lung Function, and Chronic Airflow Obstruction

    PubMed Central

    Hardin, Megan E.; Come, Carolyn E.; San José Estépar, Raúl; Ross, James C.; Kurugol, Sila; Okajima, Yuka; Han, MeiLan K.; Kim, Victor; Ramsdell, Joe; Silverman, Edwin K.; Crapo, James D.; Lynch, David A.; Make, Barry; Barr, R. Graham; Hersh, Craig P.; Washko, George R.

    2014-01-01

    Rationale and Objectives: Asthma is associated with chronic airflow obstruction. Our goal was to assess the association of computed tomographic measures of airway wall volume and lumen volume with the FEV1 and chronic airflow obstruction in smokers with childhood-onset asthma. Methods: We analyzed clinical, lung function, and volumetric computed tomographic airway volume data from 7,266 smokers, including 590 with childhood-onset asthma. Small wall volume and small lumen volume of segmental airways were defined as measures 1 SD below the mean. We assessed the association between small wall volume, small lumen volume, FEV1, and chronic airflow obstruction (post-bronchodilator FEV1/FVC ratio < 0.7) using linear and logistic models. Measurements and Main Results: Compared with subjects without childhood-onset asthma, those with childhood-onset asthma had smaller wall volume and lumen volume (P < 0.0001) of segmental airways. Among subjects with childhood-onset asthma, those with the smallest wall volume and lumen volume had the lowest FEV1 and greatest odds of chronic airflow obstruction. A similar tendency was seen in those without childhood-onset asthma. When comparing these two groups, both small wall volume and small lumen volume were more strongly associated with FEV1 and chronic airflow obstruction among subjects with childhood-asthma in multivariate models. Conclusion: In smokers with childhood-onset asthma, smaller airways are associated with reduced lung function and chronic airflow obstruction. Clinical trial registered with www.clinicaltrials.gov (NCT00608764). PMID:25296268

  1. Childhood-onset asthma in smokers. association between CT measures of airway size, lung function, and chronic airflow obstruction.

    PubMed

    Diaz, Alejandro A; Hardin, Megan E; Come, Carolyn E; San José Estépar, Raúl; Ross, James C; Kurugol, Sila; Okajima, Yuka; Han, MeiLan K; Kim, Victor; Ramsdell, Joe; Silverman, Edwin K; Crapo, James D; Lynch, David A; Make, Barry; Barr, R Graham; Hersh, Craig P; Washko, George R

    2014-11-01

    Asthma is associated with chronic airflow obstruction. Our goal was to assess the association of computed tomographic measures of airway wall volume and lumen volume with the FEV1 and chronic airflow obstruction in smokers with childhood-onset asthma. We analyzed clinical, lung function, and volumetric computed tomographic airway volume data from 7,266 smokers, including 590 with childhood-onset asthma. Small wall volume and small lumen volume of segmental airways were defined as measures 1 SD below the mean. We assessed the association between small wall volume, small lumen volume, FEV1, and chronic airflow obstruction (post-bronchodilator FEV1/FVC ratio < 0.7) using linear and logistic models. Compared with subjects without childhood-onset asthma, those with childhood-onset asthma had smaller wall volume and lumen volume (P < 0.0001) of segmental airways. Among subjects with childhood-onset asthma, those with the smallest wall volume and lumen volume had the lowest FEV1 and greatest odds of chronic airflow obstruction. A similar tendency was seen in those without childhood-onset asthma. When comparing these two groups, both small wall volume and small lumen volume were more strongly associated with FEV1 and chronic airflow obstruction among subjects with childhood-asthma in multivariate models. In smokers with childhood-onset asthma, smaller airways are associated with reduced lung function and chronic airflow obstruction. Clinical trial registered with www.clinicaltrials.gov (NCT00608764).

  2. A Computational Study of the Respiratory Airflow Characteristics in Normal and Obstructed Human Airways

    DTIC Science & Technology

    2014-01-01

    normal and three different obstructed airway geometries, consisting of symmetric, asym- metric, and random obstructions. Fig. 2 shows the geometric ...normal and obstructed airways Airway resistance is a measure of the opposition to the airflow caused by geometric properties, such as airway obstruction...pressure drops. Resistance values were dependent on the degree and geometric distribution of the obstruction sites. In the symmetric obstruction model

  3. Grading Severity of Productive Cough Based on Symptoms and Airflow Obstruction.

    PubMed

    Vazquez Guillamet, Rodrigo; Petersen, Hans; Meek, Paula; Sood, Akshay; Tesfaigzi, Yohannes

    2018-04-26

    The binary approach to the diagnosis of Chronic Bronchitis (CB) is a major barrier to the study of the disease. We investigated whether severity of productive cough can be graded using symptoms and presence of fixed airflow obstruction (FAO), and whether the severity correlates with health status, exposures injurious to the lung, biomarkers of inflammation, and measures of airway wall thickening. Findings from a cross-sectional sample of 1,422 participants from the Lovelace Smokers Cohort (LSC) were validated in 4,488 participants from the COPDGene cohort (COPDGene). Health status was based on the St. George's Respiratory Questionnaire, and Medical Outcomes Study 36-Item Short Form Health Survey. Circulating CC16 levels were quantified by ELISA (LSC), and airway wall thickening was measured using computed tomography (COPDGene). FAO was defined as postbronchodilator FEV 1 /FVC <0.7. The presence and duration of productive cough and presence of FAO or wheeze were graded into Healthy Smokers, Productive Cough (PC), Chronic PC, PC with Signs of Airflow Obstruction, and Chronic PC with Signs of Airflow Obstruction. In both cohorts, higher grade of severity correlated with lower health status, greater frequency of injurious exposures, greater airway wall thickening, and lower circulating CC16 levels. Further, longitudinal follow-up suggested that disease resolution can occur at every grade of severity but is more common in groups of lower severity and least common once airway remodeling develops. Therefore, severity of productive cough can be graded based on symptoms and FAO and early intervention may benefit patients by changing the natural history of disease.

  4. Dyssynchronous breathing during arm but not leg exercise in patients with chronic airflow obstruction.

    PubMed

    Celli, B R; Rassulo, J; Make, B J

    1986-06-05

    Some patients with chronic airflow obstruction experience dyspnea with mild arm exercise but not with more-intense leg exercise. To investigate why these patients have limited endurance during arm exertion, we studied ventilatory responses to exercise with unsupported arms in 12 patients with chronic airflow obstruction (mean [+/- SD] forced expiratory volume in one second, 0.68 +/- 0.28 liters). Unloaded leg cycling was also studied for comparison. In the five patients who had the most severe airflow obstruction, arm exercise was limited by dyspnea after 3.3 +/- 0.7 minutes, and dyssynchronous thoracoabdominal breathing developed. In the other seven patients, arm exercise was limited by the sensation of muscle fatigue after 6.1 +/- 2.0 minutes (P less than 0.05), and dyssynchronous breathing did not occur. None of the 12 patients had dyssynchronous breathing during unloaded leg cycling. Maximal transdiaphragmatic pressure, a measure of diaphragmatic fatigue, declined similarly after arm and leg exercise in both groups. During unsupported arm work, the accessory muscles of inspiration help position the torso and arms. We hypothesize that the extra demand placed on these muscles during arm exertion leads to early fatigue, an increased load on the diaphragm, and dyssynchronous thoracoabdominal inspirations. This sequence may contribute to dyspnea and limited endurance during upper-extremity exercise.

  5. Clinical characterization of children with resistant airflow obstruction, a multicenter study.

    PubMed

    Krishnan, Sankaran; Dozor, Allen J; Bacharier, Leonard; Lang, Jason E; Irvin, Charles G; Kaminsky, David; Farber, Harold J; Gerald, Lynn; Brown, Mark; Holbrook, Janet T; Wise, Robert A; Ryu, Julie; Bose, Sonali; Yasin, Razan; Saams, Joy; Henderson, Robert J; Teague, William G

    2018-05-17

    To characterize a cohort of children with airflow limitation resistant to bronchodilator (BD) therapy. Pulmonary function tests performed in children 6-17 years of age at 15 centers in a clinical research consortium were screened for resistant airflow limitation, defined as a post-BD FEV 1 and/or an FEV 1 /FVC less than the lower limits of normal. Demographic and clinical data were analyzed for associations with pulmonary function. 582 children were identified. Median age was 13 years (IQR: 11, 16), 60% were males; 62% were Caucasian, 28% were African-American; 19% were obese; 32% were born prematurely and 21% exposed to second hand smoke. Pulmonary diagnoses included asthma (93%), prior significant pneumonia (28%), and bronchiectasis (5%). 65% reported allergic rhinitis, and 11% chronic sinusitis. Subjects without a history of asthma had significantly lower post-BD FEV 1 % predicted (p = 0.008). Subjects without allergic rhinitis had lower post-BD FEV 1 % predicted (p = 0.003). Children with allergic rhinitis, male sex, obesity and Black race had better pulmonary function post-BD. There was lower pulmonary function in children after age 11 years without a history of allergic rhinitis, as compared to those with a history of allergic rhinitis. The most prevalent diagnosis in children with BD-resistant airflow limitation is asthma. Allergic rhinitis and premature birth are common co-morbidities. Children without a history of asthma, as well as those with asthma but no allergic rhinitis, had lower pulmonary function. Children with BD-resistant airflow limitation may represent a sub-group of children with persistent obstruction and high risk for life-long airway disease.

  6. Reduction of physical activity in daily life and its determinants in smokers without airflow obstruction.

    PubMed

    Furlanetto, Karina Couto; Mantoani, Leandro Cruz; Bisca, Gianna; Morita, Andrea Akemi; Zabatiero, Juliana; Proença, Mahara; Kovelis, Demétria; Pitta, Fabio

    2014-04-01

    In smokers without airflow obstruction, detailed, objective and controlled quantification of the level of physical inactivity in daily life has never been performed. This study aimed to objectively assess the level of physical activity in daily life in adult smokers without airflow obstruction in comparison with matched non-smokers, and to investigate the determinants for daily physical activity in smokers. Sixty smokers (aged 50 (39-54) years) and 50 non-smokers (aged 48 (40-53) years) matched for gender, age, anthropometric characteristics, educational level, employment status and seasons of the year assessment period were cross-sectionally assessed regarding their daily physical activity with a step counter, besides assessment of lung function, functional exercise capacity, quality of life, anxiety, depression, self-reported comorbidities carbon monoxide level, nicotine dependence and smoking habits. When compared with non-smokers, smokers walked less in daily life (7923 ± 3558 vs 9553 ± 3637 steps/day, respectively), presented worse lung function, functional exercise capacity, quality of life, anxiety and depression. Multiple regression analyses identified functional exercise capacity, Borg fatigue, self-reported motivation/physical activity behaviour and cardiac disease as significant determinants of number of steps/day in smokers (partial r(2)  = 0.10, 0.12, 0.16 and 0.05; b = 15, -997, 1207 and -2330 steps/day, respectively; overall fit of the model R(2)  = 0.38; P < 0.001). Adult smokers without airflow obstruction presented reduced level of daily physical activity. Functional exercise capacity, extended fatigue sensation, aspects of motivation/physical activity behaviour and self-reported cardiac disease are significant determinants of physical activity in daily life in smokers. © 2014 The Authors. Respirology © 2014 Asian Pacific Society of Respirology.

  7. Severity of airflow limitation, co-morbidities and management of chronic obstructive pulmonary disease patients acutely admitted to hospital.

    PubMed

    Au, L H; Chan, H S

    2013-12-01

    To assess the disease spectrum, severity of airflow limitation, admission pattern, co-morbidities, and management of patients admitted for acute exacerbations of chronic obstructive pulmonary disease. Case series. An acute regional hospital in Hong Kong. Adult subjects admitted during January 2010 to December 2010 with the principal discharge diagnosis of chronic obstructive pulmonary disease. In all, the records of 253 patients with physician-diagnosed chronic obstructive pulmonary disease were analysed. The majority were old (mean age, 78 years). The median number of admissions per patient for this condition in 2010 was two. About two thirds (64%) had had spirometry at least once. Mean forced expiratory volume in one second predicted was 55%. Almost 90% had moderate-to-very severe airflow limitation by spirometry. Overall, long-acting bronchodilators (beta agonists and/or antimuscarinics) were being prescribed for only 21% of the patients. Most of the patients admitted to hospital for acute exacerbations of chronic obstructive pulmonary disease were old, had multiple co-morbidities, and the majority had moderate-to-severe airflow limitation by spirometry. Almost half of them (around 46%) had two or more admissions in 2010. Adherence to the latest treatment guidelines seemed inadequate, there being a low prescription rate of long-acting bronchodilators. Chronic obstructive pulmonary disease patients warranting emergency admissions are at risk of future exacerbations and mortality. Management by a designated multidisciplinary team is recommended.

  8. Asymptomatic peripheral artery disease can limit maximal exercise capacity in chronic obstructive pulmonary disease patients regardless of airflow obstruction and lung hyperinflation.

    PubMed

    Crisafulli, Ernesto; Scelfo, Chiara; Tzani, Panagiota; Aiello, Marina; Bertorelli, Giuseppina; Chetta, Alfredo

    2017-06-01

    Background Silent/asymptomatic peripheral artery disease may occur in patients with chronic obstructive pulmonary disease, but it is poorly investigated. The primary aim of this study was to evaluate in chronic obstructive pulmonary disease patients the impact of asymptomatic/silent peripheral artery disease on maximal exercise capacity; the secondary aim was to search for predictors of peripheral artery disease. Methods We prospectively enrolled chronic obstructive pulmonary disease outpatients. Data on anthropometric characteristics, lung function, cardiopulmonary exercise test and ankle-brachial index were recorded. The cut-off of ankle-brachial index used to define patients with peripheral artery disease was ≤0.90. Results We studied 47 patients and found 24 patients (51%) who showed peripheral artery disease. As compared to patients without peripheral artery disease, patients with peripheral artery disease had lower values of peak oxygen uptake, peak workload, energy expenditure (metabolic equivalents) and heart rate recovery, but showed the same degree of airflow obstruction and static and dynamic hyperinflation. In a multivariate linear regression model performed to identify variables predicting metabolic equivalents, ankle-brachial index (β 2.59; 95% confidence interval 0.51-4.67; p = 0.016) was an independent variable. In the search for predictors of peripheral artery disease, heart rate recovery (odds ratio 8.80; 95% confidence interval 1.30-59.35; p = 0.026) increased the risk of peripheral artery disease, whereas metabolic equivalents (odds ratio 0.50; 95% confidence interval 0.26-0.94, p = 0.033) and inhaled corticosteroids+long-acting β 2 agonists (odds ratio 0.13; 95% confidence interval 0.02-0.83; p = 0.030) reduced this risk. Conclusions In chronic obstructive pulmonary disease outpatients, asymptomatic/silent peripheral artery disease affects the maximal exercise capacity regardless of airflow obstruction and lung

  9. Comparison between a Single-Channel Nasal Airflow Device and Oximetry for the Diagnosis of Obstructive Sleep Apnea

    PubMed Central

    Rofail, Lydia Makarie; Wong, Keith K.H.; Unger, Gunnar; Marks, Guy B.; Grunstein, Ronald R.

    2010-01-01

    Rationale: The most common single channel devices used for obstructive sleep apnea (OSA) screening are nasal airflow and oximetry. No studies have directly compared their role in diagnosing OSA at home. Study Objectives: To prospectively compare the diagnostic utility of home-based nasal airflow and oximetry to attended polysomnography (PSG) and to assess the diagnostic value of adding oximetry to nasal airflow for OSA. Design: Cross-sectional study Setting: Laboratory and home Participants: Sleep clinic patients with suspected OSA. Interventions: All patients had laboratory PSG and 2 sets of 3 consecutive nights on each device; nasal airflow (Flow Wizard, DiagnoseIT, Australia) and oximetry (Radical Set, Masimo, USA) at home in random order. Results: Ninety-eight of the 105 patients enrolled completed home monitoring. The accuracy of nasal airflow respiratory disturbance index (NF RDI) was not different from oximetry (ODI 3%) for diagnosing OSA (area under the ROC curve (AUC) difference, 0.04; 95% CI of difference −0.05 to 0.12; P = 0.43) over 3 nights of at-home recording. The accuracy of NF RDI was higher after 3 nights compared to one night (AUC difference, 0.05; 95% CI of difference, 0.01 to 0.08; P = 0.04). Addition of oximetry to nasal airflow did not increase the accuracy for predicting OSA compared to nasal airflow alone (P > 0.1). Conclusions: Nasal flow and oximetry have equivalent accuracy for diagnosing OSA in the home setting. Choice of device for home screening of sleep apnea may depend on logistical and service delivery issues. Citation: Makarie Rofail L; Wong KKH; Unger G; Marks GB; Grunstein RR. Comparison between a single-channel nasal airflow device and oximetry for the diagnosis of obstructive sleep apnea. SLEEP 2010;33(8):1106-1114. PMID:20815194

  10. Diagnostic Instability and Reversals of Chronic Obstructive Pulmonary Disease Diagnosis in Individuals with Mild to Moderate Airflow Obstruction.

    PubMed

    Aaron, Shawn D; Tan, Wan C; Bourbeau, Jean; Sin, Don D; Loves, Robyn H; MacNeil, Jenna; Whitmore, George A

    2017-08-01

    Chronic obstructive pulmonary disease (COPD) is a chronic, progressive disease, and reversal of COPD diagnosis is thought to be uncommon. To determine whether a spirometric diagnosis of mild or moderate COPD is subject to variability and potential error. We examined two prospective cohort studies that enrolled subjects with mild to moderate post-bronchodilator airflow obstruction. The Lung Health Study (n = 5,861 subjects; study duration, 5 yr) and the Canadian Cohort of Obstructive Lung Disease (CanCOLD) study (n = 1,551 subjects; study duration, 4 yr) were examined to determine frequencies of (1) diagnostic instability, represented by how often patients initially met criteria for a spirometric diagnosis of COPD but then crossed the diagnostic threshold to normal and then crossed back to COPD over a series of annual visits, or vice versa; and (2) diagnostic reversals, defined as how often an individual's COPD diagnosis at the study outset reversed to normal by the end of the study. Diagnostic instability was common and occurred in 19.5% of the Lung Health Study subjects and 6.4% of the CanCOLD subjects. Diagnostic reversals of COPD from the beginning to the end of the study period occurred in 12.6% and 27.2% of subjects in the Lung Health Study and CanCOLD study, respectively. The risk of diagnostic instability was greatest for subjects whose baseline FEV 1 /FVC value was closest to the diagnostic threshold, and the risk of diagnostic reversal was greatest for subjects who quit smoking during the study. A single post-bronchodilator spirometric assessment may not be reliable for diagnosing COPD in patients with mild to moderate airflow obstruction at baseline.

  11. [Bronchiolitis with airflow obstruction in adults].

    PubMed

    Fournier, M; Marceau, A; Dauriat, G; Camuset, J; Groussard, O

    2004-04-01

    The purpose of this paper is twofold: to describe the clinical and anatomical characteristics of bronchiolitis associated with airflow obstruction in adults; to present through a clinical approach, a classification of the main aetiologies or pathological frames associated with that entity. The constrictive bronchiolitis type is the most frequently encountered. On clinical grounds, cough, crackles, and a progressive dyspnea develop usually within a few weeks. Radiological signs of bronchiolar abnormalities are best visualized on high resolution expiratory CT scan. The decrease in maximal airflows and oxygen tension is of limited amplitude and poorly reversible with bronchodilators. Diagnosis is easily performed when a causative event, or the clinical context, can be delineated: inhalation of toxic fumes, diffuse bronchiectasis, rheumatoid arthritis, lung or bone marrow transplantation. Delayed formation of bronchiectasis in the central airways is common. The treatment is not standardized; corticosteroids are usually prescribed as a first line therapy; the benefit of the addition of, or substitution with immunosuppressive drugs has not been adequately evaluated, but is, on the mean, of limited amplitude. Recent advances in the identification of inhaled agents toxic for the distal airways help in establishing appropriate measures of prevention. When the aetiology of the bronchiolitis cannot be suspected, extensive search of a causative agent should be performed, including microbial and mineral analysis of bronchoalveolar products. Negative results should lead to perform a surgical lung biopsy. The study of chronic rejection processes in animal models of lung transplantation, the identification of inhibitory factors of bronchiolar fibrogenesis, and the efficacy of some anti-cytokines on inflammatory processes could result in new therapeutic approaches.

  12. Lung volumes identify an at-risk group in persons with prolonged secondhand tobacco smoke exposure but without overt airflow obstruction.

    PubMed

    Arjomandi, Mehrdad; Zeng, Siyang; Geerts, Jeroen; Stiner, Rachel K; Bos, Bruce; van Koeverden, Ian; Keene, Jason; Elicker, Brett; Blanc, Paul D; Gold, Warren M

    2018-01-01

    Exposure to secondhand smoke (SHS) is associated with occult obstructive lung disease as evident by abnormal airflow indices representing small airway disease despite having preserved spirometry (normal forced expiratory volume in 1 s-to-forced vital capacity ratio, FEV 1 /FVC). The significance of lung volumes that reflect air trapping in the presence of preserved spirometry is unclear. To investigate whether lung volumes representing air trapping could determine susceptibility to respiratory morbidity in people with SHS exposure but without spirometric chronic obstructive pulmonary disease, we examined a cohort of 256 subjects with prolonged occupational SHS exposure and preserved spirometry. We elicited symptom prevalence by structured questionnaires, examined functional capacity (maximum oxygen uptake, VO 2max ) by exercise testing, and estimated associations of those outcomes with air trapping (plethysmography-measured residual volume-to-total lung capacity ratio, RV/TLC), and progressive air trapping with exertion (increase in fraction of tidal breathing that is flow limited on expiration during exercise (per cent of expiratory flow limitation, %EFL)). RV/TLC was within the predicted normal limits, but was highly variable spanning 22%±13% and 16%±8% across the increments of FEV 1 /FVC and FEV 1 , respectively. Respiratory complaints were prevalent (50.4%) with the most common symptom being ≥2 episodes of cough per year (44.5%). Higher RV/TLC was associated with higher OR of reporting respiratory symptoms (n=256; r 2 =0.03; p=0.011) and lower VO 2max (n=179; r 2 =0.47; p=0.013), and %EFL was negatively associated with VO 2max (n=32; r 2 =0.40; p=0.017). In those at risk for obstruction due to SHS exposure but with preserved spirometry, higher RV/TLC identifies a subgroup with increased respiratory symptoms and lower exercise capacity.

  13. The association between chronic airflow obstruction and poverty in 12 sites of the multinational BOLD study.

    PubMed

    Townend, John; Minelli, Cosetta; Mortimer, Kevin; Obaseki, Daniel O; Al Ghobain, Mohammed; Cherkaski, Hamid; Denguezli, Myriam; Gunesekera, Kirthi; Hafizi, Hasan; Koul, Parvaiz A; Loh, Li C; Nejjari, Chakib; Patel, Jaymini; Sooronbayev, Talant; Buist, Sonia A; Burney, Peter G J

    2017-06-01

    Poverty is strongly associated with mortality from COPD, but little is known of its relation to airflow obstruction.In a cross-sectional study of adults aged ≥40 years from 12 sites (N=9255), participating in the Burden of Obstructive Lung Disease (BOLD) study, poverty was evaluated using a wealth score (0-10) based on household assets. Obstruction, measured as forced expiratory volume in 1 s (FEV 1 )/forced vital capacity (FVC) (%) after administration of 200 μg salbutamol, and prevalence of FEV 1 /FVCobstruction, from 16% in Kashmir to 3% in Riyadh and Penang (Malaysia). Following adjustments for age and sex, FEV 1 /FVC increased by 0.36% (absolute change) (95%CI: 0.22, 0.49; p<0.001) per unit increase in wealth score. Adjustments for other confounders reduced this effect to 0.23% (0.11, 0.34), but even this value remained highly significant (p<0.001). Results were consistent across sites (I 2 =1%; p het =0.44). Mean wealth scores explained 38% of the variation in mean FEV 1 /FVC between sites (r 2 =0.385, p=0.031).Airflow obstruction is consistently associated with poverty at individual and community levels across several countries. Copyright ©ERS 2017.

  14. Relationship between spontaneous expiratory flow-volume curve pattern and air-flow obstruction in elderly COPD patients.

    PubMed

    Nozoe, Masafumi; Mase, Kyoshi; Murakami, Shigefumi; Okada, Makoto; Ogino, Tomoyuki; Matsushita, Kazuhiro; Takashima, Sachie; Yamamoto, Noriyasu; Fukuda, Yoshihiro; Domen, Kazuhisa

    2013-10-01

    Assessment of the degree of air-flow obstruction is important for determining the treatment strategy in COPD patients. However, in some elderly COPD patients, measuring FVC is impossible because of cognitive dysfunction or severe dyspnea. In such patients a simple test of airways obstruction requiring only a short run of tidal breathing would be useful. We studied whether the spontaneous expiratory flow-volume (SEFV) curve pattern reflects the degree of air-flow obstruction in elderly COPD patients. In 34 elderly subjects (mean ± SD age 80 ± 7 y) with stable COPD (percent-of-predicted FEV(1) 39.0 ± 18.5%), and 12 age-matched healthy subjects, we measured FVC and recorded flow-volume curves during quiet breathing. We studied the SEFV curve patterns (concavity/convexity), spirometry results, breathing patterns, and demographics. The SEFV curve concavity/convexity prediction accuracy was examined by calculating the receiver operating characteristic curves, cutoff values, area under the curve, sensitivity, and specificity. Fourteen subjects with COPD had a concave SEFV curve. All the healthy subjects had convex SEFV curves. The COPD subjects who had concave SEFV curves often had very severe airway obstruction. The percent-of-predicted FEV(1)% (32.4%) was the most powerful SEFV curve concavity predictor (area under the curve 0.92, 95% CI 0.83-1.00), and had the highest sensitivity (0.93) and specificity (0.88). Concavity of the SEFV curve obtained during tidal breathing may be a useful test for determining the presence of very severe obstruction in elderly patients unable to perform a satisfactory FVC maneuver.

  15. Effect of Fluticasone Furoate and Vilanterol on Exacerbations of Chronic Obstructive Pulmonary Disease in Patients with Moderate Airflow Obstruction.

    PubMed

    Martinez, Fernando J; Vestbo, Jørgen; Anderson, Julie A; Brook, Robert D; Celli, Bartolome R; Cowans, Nicholas J; Crim, Courtney; Dransfield, Mark; Kilbride, Sally; Yates, Julie; Newby, David E; Niewoehner, Dennis; Calverley, Peter M A

    2017-04-01

    Inhaled corticosteroids have been shown to decrease exacerbations in patients with moderate to severe chronic obstructive pulmonary disease (COPD). Their effects in patients with milder airflow obstruction remain unclear. This was an analysis of exacerbations in the SUMMIT (Study to Understand Mortality and Morbidity) study. In a double-blind, randomized controlled trial, once-daily inhaled placebo, fluticasone furoate (FF; 100 μg), vilanterol (VI; 25 μg), or the combination of FF/VI was administered. The primary outcome was all-cause mortality. Exacerbations of COPD were an additional predefined endpoint. A total of 1,368 centers in 43 countries and 16,485 patients with moderate COPD and heightened cardiovascular risk were included in the study. Compared with placebo, FF/VI reduced the rate of moderate and/or severe exacerbations by 29% (95% confidence interval [CI], 22-35; P < 0.001) and the rate of hospitalized exacerbations by 27% (95% CI, 13-39; P < 0.001). These relative effects were similar regardless of whether subjects had a history of exacerbation in the year before the study or an FEV 1 <60% or ≥60% of predicted. The number needed to treat was not influenced by baseline FEV 1 but was influenced by the history of exacerbations. FF/VI also reduced the rate of exacerbations treated with corticosteroids alone or with corticosteroids and antibiotics but not the rates of those treated with antibiotics alone. Patients with moderate chronic airflow obstruction experienced a reduction in exacerbations with FF/VI compared with placebo, irrespective of a history of exacerbations or baseline FEV 1 . Clinical trial registered with www.clinicaltrials.gov (NCT 01313676; GSK Study number 113782).

  16. Free DNA in Cystic Fibrosis Airway Fluids Correlates with Airflow Obstruction

    PubMed Central

    Marcos, Veronica; Zhou-Suckow, Zhe; Önder Yildirim, Ali; Bohla, Alexander; Hector, Andreas; Vitkov, Ljubomir; Krautgartner, Wolf Dietrich; Stoiber, Walter; Griese, Matthias; Eickelberg, Oliver; Mall, Marcus A.; Hartl, Dominik

    2015-01-01

    Chronic obstructive lung disease determines morbidity and mortality of patients with cystic fibrosis (CF). CF airways are characterized by a nonresolving neutrophilic inflammation. After pathogen contact or prolonged activation, neutrophils release DNA fibres decorated with antimicrobial proteins, forming neutrophil extracellular traps (NETs). NETs have been described to act in a beneficial way for innate host defense by bactericidal, fungicidal, and virucidal actions. On the other hand, excessive NET formation has been linked to the pathogenesis of autoinflammatory and autoimmune disease conditions. We quantified free DNA structures characteristic of NETs in airway fluids of CF patients and a mouse model with CF-like lung disease. Free DNA levels correlated with airflow obstruction, fungal colonization, and CXC chemokine levels in CF patients and CF-like mice. When viewed in combination, our results demonstrate that neutrophilic inflammation in CF airways is associated with abundant free DNA characteristic for NETosis, and suggest that free DNA may be implicated in lung function decline in patients with CF. PMID:25918476

  17. Attenuation of tachykinin-induced airflow obstruction and microvascular leakage in immature airways.

    PubMed Central

    Tokuyama, K.; Yokoyama, T.; Morikawa, A.; Mochizuki, H.; Kuroume, T.; Barnes, P. J.

    1993-01-01

    1. To study the effect of maturation on substance P (SP)- and neurokinin A (NKA)-induced airflow obstruction and airway microvascular leakage (MVL), we have measured changes in both lung resistance (RL) and extravasation of Evans blue dye in anaesthetized immature (aged 14 +/- 1 days) and adult guinea-pigs (aged 80 +/- 3 days). 2. RL and its recovery after hyperinflation at 5 min were measured for 6 min after i.v. SP (0.2, 1 and 30 nmol kg-1), NKA (1 and 10 nmol kg-1) or vehicle (0.9% NaCl). After measurement of RL, MVL in trachea, main bronchi and intrapulmonary airways was also examined. 3. The order of potency in inducing airflow obstruction did not change with age (NKA > SP) but immature animals required a larger dose of SP or NKA than adults to cause a significant increase in RL. 4. The order of potency in inducing airway microvascular leakage was SP > NKA in both immature and adult animals. The amount of extravasated dye after SP was significantly less in immature airways, especially in central airways. 5. Phosphoramidon (2.5 mg kg-1), a neutral endopeptidase (NEP) inhibitor, significantly increased RL after 0.2 nmol kg-1 SP only in adult airways. Phosphoramidon enhanced the dye extravasation after 0.2 nmol kg-1 SP in both immature and adult airways with a significantly greater amount of dye in adult animals, suggesting that mechanisms other than changes in NEP activity may be responsible for this age-related difference.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7679033

  18. Relation of pulmonary vessel size to transfer factor in subjects with airflow obstruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Musk, A.W.

    In a group of 61 consecutive patients undergoing assessment of airflow obstruction, a significant linear relation was demonstrated between measurements of the diameter of the midzonal pulmonary vessels on the plain chest radiographs and transfer factor (diffusing capacity for carbon monoxide) (r = 0.46, p < 0.001). Since reduction in transfer factor has been shown to relate to structural emphysema, reduction in midzone vessel caliber implies the same. However, in the individual patient neither the transfer factor nor structural emphysema can be reliably predicted from midzone vessel diameters alone.

  19. Bronchodilator Response in FVC Is Larger and More Relevant Than in FEV1 in Severe Airflow Obstruction.

    PubMed

    Quanjer, Philip H; Ruppel, Gregg L; Langhammer, Arnulf; Krishna, Abhishek; Mertens, Frans; Johannessen, Ane; Menezes, Ana M B; Wehrmeister, Fernando C; Perez-Padilla, Rogelio; Swanney, Maureen P; Tan, Wan C; Bourbeau, Jean

    2017-05-01

    Recommendations on interpreting tests of bronchodilator responsiveness (BDR) are conflicting. We investigated the dependence of BDR criteria on sex, age, height, ethnicity, and severity of respiratory impairment. BDR test data were available from clinical patients in the Netherlands, New Zealand, and the United States (n = 15,278; female subjects, 51.7%) and from surveys in Canada, Norway, and five Latin-American countries (n = 16,250; female subjects, 54.7%). BDR calculated according to FEV 1 , FVC, and FEV 1 /FVC was expressed as absolute change, a percentage of the baseline level (% baseline), a percentage of the predicted value (% predicted), and z score. Change (Δ) in FEV 1 and FVC, in milliliters, was unrelated to the baseline value but was biased toward age, height, sex, and level of airways obstruction; ΔFEV 1 was significantly lower in African Americans. In 1,106 subjects with low FEV 1 (200-1,621 mL) the FEV 1 increased by 12% to 44.7% relative to baseline but < 200 mL. Expressing BDR as a percentage of the predicted value or as a z score attenuated the bias and made the 200-mL criterion redundant, but reduced positive responses by half. ΔFEV 1 % baseline increased with the level of airflow obstruction but decreased with severe obstruction when expressed as z scores or % predicted; ΔFVC, however expressed, increased with the level of airflow obstruction. Expressing FEV 1 responsiveness as % baseline spuriously suggests that responsiveness increases with the severity of respiratory impairment. Expressing change in FEV 1 or FVC as % predicted or as z scores eliminates this artifact and renders the required 200-mL minimum increase redundant. In severe airways obstruction ΔFVC should be critically evaluated as an index of clinically important relief of hyperinflation, with implications for bronchodilator drug trials. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  20. Severity of Airflow Obstruction in Chronic Obstructive Pulmonary Disease (COPD): Proposal for a New Classification.

    PubMed

    Coton, Sonia; Vollmer, William M; Bateman, Eric; Marks, Guy B; Tan, Wan; Mejza, Filip; Juvekar, Sanjay; Janson, Christer; Mortimer, Kevin; P A, Mahesh; Buist, A Sonia; Burney, Peter G J

    2017-10-01

    Current classifications of Chronic Obstructive Pulmonary Disease (COPD) severity are complex and do not grade levels of obstruction. Obstruction is a simpler construct and independent of ethnicity. We constructed an index of obstruction severity based on the FEV 1 /FVC ratio, with cut-points dividing the Burden of Obstructive Lung Disease (BOLD) study population into four similarly sized strata to those created by the GOLD criteria that uses FEV 1 . We measured the agreement between classifications and the validity of the FEV 1 -based classification in identifying the level of obstruction as defined by the new groupings. We compared the strengths of association of each classification with quality of life (QoL), MRC dyspnoea score and the self-reported exacerbation rate. Agreement between classifications was only fair. FEV 1 -based criteria for moderate COPD identified only 79% of those with moderate obstruction and misclassified half of the participants with mild obstruction as having more severe COPD. Both scales were equally strongly associated with QoL, exertional dyspnoea and respiratory exacerbations. Severity assessed using the FEV 1 /FVC ratio is only in moderate agreement with the severity assessed using FEV 1 but is equally strongly associated with other outcomes. Severity assessed using the FEV 1 /FVC ratio is likely to be independent of ethnicity.

  1. Substance deposition assessment in obstructed pulmonary system through numerical characterization of airflow and inhaled particles attributes.

    PubMed

    Lalas, Antonios; Nousias, Stavros; Kikidis, Dimitrios; Lalos, Aris; Arvanitis, Gerasimos; Sougles, Christos; Moustakas, Konstantinos; Votis, Konstantinos; Verbanck, Sylvia; Usmani, Omar; Tzovaras, Dimitrios

    2017-12-20

    Chronic obstructive pulmonary disease (COPD) and asthma are considered as the two most widespread obstructive lung diseases, whereas they affect more than 500 million people worldwide. Unfortunately, the requirement for detailed geometric models of the lungs in combination with the increased computational resources needed for the simulation of the breathing did not allow great progress to be made in the past for the better understanding of inflammatory diseases of the airways through detailed modelling approaches. In this context, computational fluid dynamics (CFD) simulations accompanied by fluid particle tracing (FPT) analysis of the inhaled ambient particles are deemed critical for lung function assessment. Also they enable the understanding of particle depositions on the airways of patients, since these accumulations may affect or lead to inflammations. In this direction, the current study conducts an initial investigation for the better comprehension of particle deposition within the lungs. More specifically, accurate models of the airways obstructions that relate to pulmonary disease are developed and a thorough assessment of the airflow behavior together with identification of the effects of inhaled particle properties, such as size and density, is conducted. Our approach presents a first step towards an effective personalization of pulmonary treatment in regards to the geometric characteristics of the lungs and the in depth understanding of airflows within the airways. A geometry processing technique involving contraction algorithms is established and used to employ the different respiratory arrangements associated with lung related diseases that exhibit airways obstructions. Apart from the normal lung case, two categories of obstructed cases are examined, i.e. models with obstructions in both lungs and models with narrowings in the right lung only. Precise assumptions regarding airflow and deposition fraction (DF) over various sections of the lungs are

  2. Nasal lavage cellularity, grain dust, and airflow obstruction.

    PubMed

    Blaski, C A; Watt, J L; Quinn, T J; Thorne, P S; Schwartz, D A

    1996-04-01

    . However, the NL cellularity does not appear to be associated with ambient concentrations of dusts or endotoxins, with signs of airflow obstruction, or with work-related respiratory symptoms.

  3. Phenotypic and genetic heterogeneity among subjects with mild airflow obstruction in COPDGene.

    PubMed

    Lee, Jin Hwa; Cho, Michael H; McDonald, Merry-Lynn N; Hersh, Craig P; Castaldi, Peter J; Crapo, James D; Wan, Emily S; Dy, Jennifer G; Chang, Yale; Regan, Elizabeth A; Hardin, Megan; DeMeo, Dawn L; Silverman, Edwin K

    2014-10-01

    Chronic obstructive pulmonary disease (COPD) is characterized by marked phenotypic heterogeneity. Most previous studies have focused on COPD subjects with FEV1 < 80% predicted. We investigated the clinical and genetic heterogeneity in subjects with mild airflow limitation in spirometry grade 1 defined by the Global Initiative for chronic Obstructive Lung Disease (GOLD 1). Data from current and former smokers participating in the COPDGene Study (NCT00608764) were analyzed. K-means clustering was performed to explore subtypes within 794 GOLD 1 subjects. For all subjects with GOLD 1 and with each cluster, a genome-wide association study and candidate gene testing were performed using smokers with normal lung function as a control group. Combinations of COPD genome-wide significant single nucleotide polymorphisms (SNPs) were tested for association with FEV1 (% predicted) in GOLD 1 and in a combined group of GOLD 1 and smoking control subjects. K-means clustering of GOLD 1 subjects identified putative "near-normal", "airway-predominant", "emphysema-predominant" and "lowest FEV1% predicted" subtypes. In non-Hispanic whites, the only SNP nominally associated with GOLD 1 status relative to smoking controls was rs7671167 (FAM13A) in logistic regression models with adjustment for age, sex, pack-years of smoking, and genetic ancestry. The emphysema-predominant GOLD 1 cluster was nominally associated with rs7671167 (FAM13A) and rs161976 (BICD1). The lowest FEV1% predicted cluster was nominally associated with rs1980057 (HHIP) and rs1051730 (CHRNA3). Combinations of COPD genome-wide significant SNPs were associated with FEV1 (% predicted) in a combined group of GOLD 1 and smoking control subjects. Our results indicate that GOLD 1 subjects show substantial clinical heterogeneity, which is at least partially related to genetic heterogeneity. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. PHENOTYPIC AND GENETIC HETEROGENEITY AMONG SUBJECTS WITH MILD AIRFLOW OBSTRUCTION IN COPDGENE

    PubMed Central

    Lee, Jin Hwa; Cho, Michael H.; McDonald, Merry-Lynn N.; Hersh, Craig P.; Castaldi, Peter J.; Crapo, James D.; Wan, Emily S.; Dy, Jennifer G.; Chang, Yale; Regan, Elizabeth A.; Hardin, Megan; DeMeo, Dawn L.; Silverman, Edwin K.

    2014-01-01

    Background Chronic obstructive pulmonary disease (COPD) is characterized by marked phenotypic heterogeneity. Most previous studies have focused on COPD subjects with FEV1 < 80% predicted. We investigated the clinical and genetic heterogeneity in subjects with mild airflow limitation in spirometry grade 1 defined by the Global Initiative for chronic Obstructive Lung Disease (GOLD 1). Methods Data from current and former smokers participating in the COPDGene Study (NCT00608764) were analyzed. K-means clustering was performed to explore subtypes within 794 GOLD 1 subjects. For all subjects with GOLD 1 and with each cluster, a genome-wide association study and candidate gene testing were performed using smokers with normal lung function as a control group. Combinations of COPD genome-wide significant single nucleotide polymorphisms (SNPs) were tested for association with FEV1 (% predicted) in GOLD 1 and in a combined group of GOLD1 and smoking control subjects. Results K-means clustering of GOLD 1 subjects identified putative “near-normal”, “airway-predominant”, “emphysema-predominant” and “lowest FEV1 % predicted” subtypes. In non-Hispanic whites, the only SNP nominally associated with GOLD 1 status relative to smoking controls was rs7671167 (FAM13A) in logistic regression models with adjustment for age, sex, pack-years of smoking, and genetic ancestry. The emphysema-predominant GOLD 1 cluster was nominally associated with rs7671167 (FAM13A) and rs161976 (BICD1). The lowest FEV1 % predicted cluster was nominally associated with rs1980057 (HHIP) and rs1051730 (CHRNA3). Combinations of COPD genome-wide significant SNPs were associated with FEV1 (% predicted) in a combined group of GOLD 1 and smoking control subjects. Conclusions Our results indicate that GOLD 1 subjects show substantial clinical heterogeneity, which is at least partially related to genetic heterogeneity. PMID:25154699

  5. Genetic regulation of gene expression in the lung identifies CST3 and CD22 as potential causal genes for airflow obstruction.

    PubMed

    Lamontagne, Maxime; Timens, Wim; Hao, Ke; Bossé, Yohan; Laviolette, Michel; Steiling, Katrina; Campbell, Joshua D; Couture, Christian; Conti, Massimo; Sherwood, Karen; Hogg, James C; Brandsma, Corry-Anke; van den Berge, Maarten; Sandford, Andrew; Lam, Stephen; Lenburg, Marc E; Spira, Avrum; Paré, Peter D; Nickle, David; Sin, Don D; Postma, Dirkje S

    2014-11-01

    COPD is a complex chronic disease with poorly understood pathogenesis. Integrative genomic approaches have the potential to elucidate the biological networks underlying COPD and lung function. We recently combined genome-wide genotyping and gene expression in 1111 human lung specimens to map expression quantitative trait loci (eQTL). To determine causal associations between COPD and lung function-associated single nucleotide polymorphisms (SNPs) and lung tissue gene expression changes in our lung eQTL dataset. We evaluated causality between SNPs and gene expression for three COPD phenotypes: FEV(1)% predicted, FEV(1)/FVC and COPD as a categorical variable. Different models were assessed in the three cohorts independently and in a meta-analysis. SNPs associated with a COPD phenotype and gene expression were subjected to causal pathway modelling and manual curation. In silico analyses evaluated functional enrichment of biological pathways among newly identified causal genes. Biologically relevant causal genes were validated in two separate gene expression datasets of lung tissues and bronchial airway brushings. High reliability causal relations were found in SNP-mRNA-phenotype triplets for FEV(1)% predicted (n=169) and FEV(1)/FVC (n=80). Several genes of potential biological relevance for COPD were revealed. eQTL-SNPs upregulating cystatin C (CST3) and CD22 were associated with worse lung function. Signalling pathways enriched with causal genes included xenobiotic metabolism, apoptosis, protease-antiprotease and oxidant-antioxidant balance. By using integrative genomics and analysing the relationships of COPD phenotypes with SNPs and gene expression in lung tissue, we identified CST3 and CD22 as potential causal genes for airflow obstruction. This study also augmented the understanding of previously described COPD pathways. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. Prevalence of airflow obstruction and reduced forced vital capacity in an Aboriginal Australian population: The cross-sectional BOLD study.

    PubMed

    Cooksley, Nathania A J B; Atkinson, David; Marks, Guy B; Toelle, Brett G; Reeve, David; Johns, David P; Abramson, Michael J; Burton, Deborah L; James, Alan L; Wood-Baker, Richard; Walters, E Haydn; Buist, A Sonia; Maguire, Graeme P

    2015-07-01

    Mortality and hospital separation data suggest a higher burden of chronic obstructive pulmonary disease (COPD) in indigenous than non-indigenous subpopulations of high-income countries. This study sought to accurately measure the true prevalence of post-bronchodilator airflow obstruction and forced vital capacity reduction in representative samples of Indigenous and non-Indigenous Australians. This study applies cross-sectional population-based survey of Aboriginal and non-Indigenous residents of the Kimberley region of Western Australia aged 40 years or older, following the international Burden Of Lung Disease (BOLD) protocol. Quality-controlled spirometry was conducted before and after bronchodilator. COPD was defined as Global initiative for chronic Obstructive Lung Disease (GOLD) Stage 2 and above (post-bronchodilator forced expiratory volume in 1 s/forced vital capacity (FEV1 /FVC) ratio <0.7 and FEV1  < 80% predicted). Complete data were available for 704 participants. The prevalence of COPD, adjusted for age, gender and body weight in Aboriginal participants (7.2%, 95% confidence interval (CI) 3.9 to 10.4) was similar to that seen in non-Indigenous Kimberley participants (8.2%, 95% CI 5.7 to 10.7) and non-Indigenous residents of the remainder of Australia (7.1%, 95% CI 6.1 to 8.0). The prevalence of low FVC (<80% predicted) was substantially higher in Aboriginal compared with non-Indigenous participants (74.0%, 95% CI 69.1 to 78.8, vs 9.7%, 95% CI 7.1 to 12.4). Low FVC, rather than airflow obstruction, characterizes the impact of chronic lung disease previously attributed to COPD in this population subject to significant social and economic disadvantage. Environmental risk factors other than smoking as well as developmental factors must be considered. These findings require further investigation and have implications for future prevention of chronic lung disease in similar populations. © 2015 Asian Pacific Society of Respirology.

  7. CO diffusing capacity in a general population sample: relationships with cigarette smoking and airflow obstruction.

    PubMed

    Viegi, G; Paoletti, P; Carrozzi, L; Baldacci, S; Modena, P; Pedreschi, M; Di Pede, F; Mammini, U; Giuntini, C

    1993-01-01

    The single-breath carbon monoxide diffusing capacity (DLCOsb) was measured together with ventilatory lung function tests as part of a survey of a general population sample living in Northern Italy (n = 2,481). Based on answers to an interviewer-administered questionnaire, subjects free of respiratory symptoms or diseases were identified. Data from subjects who had never regularly smoked cigarettes were used to derive reference equations for the test indexes, and data from the remaining subjects who had smoked were used to derive regression equations incorporating a term expressing cigarette consumption (cube root of pack-years) and a term indicating current smoking decrement, in order to obtain expected DLCOsb percent predicted. Neither number of cigarettes smoked daily or duration of smoking, in smokers, nor duration of smoking or years since quitting smoking, in ex-smokers, entered significantly the multiple-regression model. The mean values of DLCOsb were only slightly affected by the increasing degree of airway obstruction. When subjects with confirmed asthma were analyzed, after stratifying for different levels of FEV1/FVC ratio, increased mean value of DLCOsb (over 100%) was found in those with an FEV1/FVC ratio between 75 and 65%. This cross-sectional analysis suggests that there is a decrease in DLCOsb with cumulative cigarette consumption even in healthy subjects. Further, it confirms the clinical observations of high DLCOsb values in asthmatic patients, at least in those with an initial degree of chronic airflow obstruction.

  8. Association of emphysema-like lung on cardiac computed tomography and mortality in persons without airflow obstruction: the Multi-Ethnic Study of Atherosclerosis (MESA) Lung Study

    PubMed Central

    Oelsner, Elizabeth C.; Hoffman, Eric A.; Folsom, Aaron R.; Carr, J. Jeffrey; Enright, Paul L.; Kawut, Steven M.; Kronmal, Richard; Lederer, David; Lima, Joao A. C.; Lovasi, Gina S.; Shea, Steven; Barr, R. Graham

    2015-01-01

    Background Whereas low lung function is known to predict mortality in the general population, the prognostic significance of emphysema on computed tomography (CT) in persons without chronic obstructive pulmonary disease (COPD) remains uncertain. Objective To determine whether greater emphysema-like lung on CT is associated with all-cause mortality among persons without airflow obstruction or COPD in the general population. Design Prospective cohort study. Setting Population-based, multiethnic sample from 6 US communities. Participants 2965 participants ages 45-84 years without airflow obstruction on spirometry. Measurements Emphysema-like lung was defined on cardiac CT as the number of lung voxels less than -950 Hounsfield Units, and was adjusted for the number of total imaged lung voxels. Results Among 2965 participants, 50.9% of whom never smoked, there were 186 deaths over a median of 6.2 years. Greater emphysema-like lung was independently associated with increased mortality (adjusted hazard ratio [HR]1.14 per one-half of the interquartile range, 95% CI 1.04-1.24, P=0.004), adjusting for potential confounders including cardiovascular risk factors and the forced expiratory volume in one second. Generalized additive models supported a linear association between emphysema-like lung and mortality without evidence for a threshold. The association was of greatest magnitude among smokers, although multiplicative interaction terms did not support effect modification by smoking status. Limitations Cardiac CT scans did not include lung apices. The number of deaths was limited among subgroup analyses. Conclusions Emphysema-like lung on CT was associated with all-cause mortality among persons without airflow obstruction or COPD in a general population sample, particularly among smokers. Recognition of the independent prognostic significance of emphysema on CT among patients without COPD on spirometry is warranted. Primary Funding Source NIH/NHLBI. PMID:25506855

  9. Surgical management of nasal obstruction.

    PubMed

    Moche, Jason A; Palmer, Orville

    2012-05-01

    The proper evaluation of the patient with nasal obstruction relies on a comprehensive history and physical examination. Once the site of obstruction is accurately identified, the patient may benefit from a trial of medical management. At times however, the definitive treatment of nasal obstruction relies on surgical management. Recognizing the nasal septum, nasal valve, and turbinates as possible sites of obstruction and addressing them accordingly can dramatically improve a patient's nasal breathing. Conservative resection of septal cartilage, submucous reduction of the inferior turbinate, and structural grafting of the nasal valve when appropriate will provide the optimal improvement in nasal airflow and allow for the most stable results. Copyright © 2012. Published by Elsevier Inc.

  10. Tuberculosis associated chronic obstructive pulmonary disease.

    PubMed

    Sarkar, Malay; Srinivasa; Madabhavi, Irappa; Kumar, Kushal

    2017-05-01

    Reviewed the epidemiology, clinical characteristics, mechanisms, and treatment of tuberculosis associated chronic obstructive pulmonary disease. We searched PubMed, EMBASE, and the CINAHL from inception to June 2016. We used the following search terms: Tuberculosis, COPD, Tuberculosis associated COPD, and so forth. All types of study were chosen. Chronic obstructive pulmonary disease (COPD) and tuberculosis are significant public health problems, particularly in developing countries. Although, smoking is the conventional risk factor for COPD, nonsmoking related risk factors such as biomass fuel exposure, childhood lower-respiratory tract infections, chronic asthma, outdoor air pollution, and prior history of pulmonary tuberculosis have become important risk factors of COPD, particularly in developing countries. Past history of tuberculosis as a risk factor of chronic airflow obstruction has been reported in several studies. It may develop during the course of tuberculosis or after completion of tuberculosis treatment. Developing countries with large burden of tuberculosis can contribute significantly to the burden of chronic airflow obstruction. Prompt diagnosis and treatment of tuberculosis should be emphasized to lessen the future burden of chronic airflow obstruction. © 2017 John Wiley & Sons Ltd.

  11. Airflow obstruction case finding in community-pharmacies: a novel strategy to reduce COPD underdiagnosis.

    PubMed

    Castillo, D; Burgos, F; Guayta, R; Giner, J; Lozano, P; Estrada, M; Soriano, J B; Flor, X; Barau, M; Casan, P

    2015-04-01

    Community pharmacies (CP) have access to subjects at high-risk of suffering Chronic Obstructive Pulmonary Disease (COPD). We investigated if a COPD case finding program in CP could be a new strategy to reduce COPD underdiagnosis. Prospective, cross-sectional, descriptive, uncontrolled, remotely supported study in 100 CP in Barcelona, Spain. Pharmacists were trained in a four-day workshop on spirometry and COPD, and each was provided with a spirometer for 12 weeks. The program included questionnaires and forced spirometry measurements, whose quality was controlled and monitored by web-assistance. Overall 2295 (73.5%), of 3121 CP customers invited to participate in the program accepted, and 1.456 (63.4%) were identified as "high risk" for COPD using the GOLD questionnaire. Only 33 could not conduct spirometry, and a pre-bronchodilator airflow limitation (FEV1/FVC ratio <0.7) was confirmed in 282 (19.8%); 244 of these were referred to their primary care (PC) physician for further diagnostic and therapeutic work-up, but only 39 of them (16%) fed-back this information to the pharmacist. Clinically acceptable quality spirometries (grade A or B) were obtained in 69.4% of the cases. This study shows that adequately trained and supported community pharmacists can effectively identify individuals at high risk of having COPD and can thus contribute to ameliorate underdiagnosis in this disease. Links between PC and CP should be improved to achieve a useful program. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Chronic Airflow Obstruction in a Black African Population: Results of BOLD Study, Ile-Ife, Nigeria.

    PubMed

    Obaseki, Daniel O; Erhabor, Gregory E; Gnatiuc, Louisa; Adewole, Olufemi O; Buist, Sonia A; Burney, Peter G

    2016-01-01

    Global estimates suggest that Chronic Obstructive Pulmonary Disease (COPD) is emerging as a leading cause of death in developing countries but there are few spirometry-based general population data on its prevalence and risk factors in sub-Saharan Africa. We used the Burden of Obstructive Lung Disease (BOLD) protocol to select a representative sample of adults aged 40 years and above in Ile-Ife, Nigeria. All the participants underwent spirometry and provided information on smoking history, biomass and occupational exposures as well as diagnosed respiratory diseases and symptoms. Chronic Airflow Obstruction (CAO) was defined as the ratio of post-bronchodilator (BD) one second Forced Expiratory Volume (FEV1) to Forced Vital Capacity (FVC) below the lower limit of normal (LLN) of the population distribution for FEV1/FVC. The overall prevalence of obstruction (post-BD FEV1/FVC < LLN) was 7.7% (2.7% above LLN) using Global Lung Function Initiative (GLI) equations. It was associated with few respiratory symptoms; 0.3% reported a previous doctor-diagnosed chronic bronchitis, emphysema or COPD. Independent predictors included a lack of education (OR 2.5, 95% CI: 1.0, 6.4) and a diagnosis of either TB (OR 23.4, 95% CI: 2.0, 278.6) or asthma (OR 35.4, 95%CI: 4.9, 255.8). There was no association with the use of firewood or coal for cooking or heating. The vast majority of this population (89%) are never smokers. We conclude that the prevalence of CAO is low in Ile-Ife, Nigeria and unrelated to biomass exposure. The key independent predictors are poor education, and previous diagnosis of tuberculosis or asthma.

  13. Unemployment in chronic airflow obstruction around the world: results from the BOLD study.

    PubMed

    Grønseth, Rune; Erdal, Marta; Tan, Wan C; Obaseki, Daniel O; Amaral, Andre F S; Gislason, Thorarinn; Juvekar, Sanjay K; Koul, Parvaiz A; Studnicka, Michael; Salvi, Sundeep; Burney, Peter; Buist, A Sonia; Vollmer, William M; Johannessen, Ane

    2017-09-01

    We aimed to examine associations between chronic airflow obstruction (CAO) and unemployment across the world.Cross-sectional data from 26 sites in the Burden of Obstructive Lung Disease (BOLD) study were used to analyse effects of CAO on unemployment. Odds ratios for unemployment in subjects aged 40-65 years were estimated using a multilevel mixed-effects generalised linear model with study site as random effect. Site-by-site heterogeneity was assessed using individual participant data meta-analyses.Out of 18 710 participants, 11.3% had CAO. The ratio of unemployed subjects with CAO divided by subjects without CAO showed large site discrepancies, although these were no longer significant after adjusting for age, sex, smoking and education. The site-adjusted odds ratio (95% CI) for unemployment was 1.79 (1.41-2.27) for CAO cases, decreasing to 1.43 (1.14-1.79) after adjusting for sociodemographic factors, comorbidities and forced vital capacity. Of other covariates that were associated with unemployment, age and education were important risk factors in high-income sites (4.02 (3.53-4.57) and 3.86 (2.80-5.30), respectively), while female sex was important in low- to middle-income sites (3.23 (2.66-3.91)).In the global BOLD study, CAO was associated with increased levels of unemployment, even after adjusting for sociodemographic factors, comorbidities and lung function. Copyright ©ERS 2017.

  14. Interleukin-6 and airflow limitation in chemical warfare patients with chronic obstructive pulmonary disease

    PubMed Central

    Attaran, Davood; Lari, Shahrzad M; Towhidi, Mohammad; Marallu, Hassan Ghobadi; Ayatollahi, Hossein; Khajehdaluee, Mohammad; Ghanei, Mostafa; Basiri, Reza

    2010-01-01

    Objectives Chronic obstructive pulmonary disease (COPD) is one of the main late complications of sulfur mustard poisoning. The aim of this study was to evaluate serum levels of interleukin (IL)-6 in war veterans with pulmonary complications of sulfur mustard poisoning and their correlation with severity of airways disease. Methods Fifty consecutive patients with sulfur mustard poisoning and stable COPD, and of mean age 46.3 ± 9.18 years were enrolled in this study. Thirty healthy men were selected as controls and matched to cases by age and body mass index. Spirometry, arterial blood gas, six- minute walk test, BODE (body mass index, obstruction, dyspnea, and exercise capacity), and St George’s Respiratory Questionnaire about quality of life were evaluated. Serum IL-6 was measured in both patient and control groups. Results Fifty-four percent of patients had moderate COPD. Mean serum IL-6 levels were 15.01 ± standard deviation (SD) 0.61 pg/dL and 4.59 ± 3.40 pg/dL in the case and control groups, respectively (P = 0.03). There was a significant correlation between IL-6 levels and Global Initiative for Chronic Obstructive Lung Disease stage (r = 0.25, P = 0.04) and between IL-6 and BODE index (r = 0.38, P = 0.01). There was also a significant negative correlation between serum IL-6 and forced expiratory volume in one second (FEV1, r = −0.36, P = 0.016). Conclusion Our findings suggest that serum IL-6 is increased in patients with sulfur mustard poisoning and COPD, and may have a direct association with airflow limitation. PMID:21037957

  15. Differential effects of phosphoramidon on neurokinin A- and substance P-induced airflow obstruction and airway microvascular leakage in guinea-pig.

    PubMed Central

    Lötvall, J. O.; Elwood, W.; Tokuyama, K.; Barnes, P. J.; Chung, K. F.

    1991-01-01

    1. The effects of the inhaled neuropeptides, neurokinin A (NKA) and substance P (SP) on lung resistance (RL) and airway microvascular permeability were studied in anaesthetized guinea-pigs. 2. Single doses of inhaled NKA (3 x 10(-5), 1 x 10(-4), 3 x 10(-4) M; 45 breaths) and SP (1 x 10(-4), 3 x 10(-4), 1 x 10(-3); 45 breaths) caused a dose-dependent increase in both RL and airway microvascular leakage, assessed as extravasation of the albumin marker, Evans blue dye. 3. NKA at 1 x 10(-4) and 3 x 10(-4) M resulted in a significantly higher increase in RL than SP at the same doses. 4. Inhaled SP (3 x 10(-4) M; 45 breaths) caused significantly higher Evans blue dye extravasation in main bronchi and proximal intrapulmonary airways compared to the same dose of NKA. 5. Pretreatment with the specific inhibitor of neural endopeptidase (NEP24.11), phosphoramidon, caused an approximately 100 fold leftward shift of the RL responses to inhaled NKA and SP. 6. Phosphoramidon significantly potentiated both NKA- and SP-induced airway microvascular leakage at proximal intrapulmonary airways, but not at any other airway level. 7. Inhibition of NEP24.11 potentiate both the SP- or NKA-induced airflow obstruction to a larger extent than the induced airway microvascular leakage, suggesting that NEP24.11 is more important in the modulation of the airflow obstruction observed after these mediators. PMID:1725766

  16. Differential effects of phosphoramidon on neurokinin A- and substance P-induced airflow obstruction and airway microvascular leakage in guinea-pig.

    PubMed

    Lötvall, J O; Elwood, W; Tokuyama, K; Barnes, P J; Chung, K F

    1991-12-01

    1. The effects of the inhaled neuropeptides, neurokinin A (NKA) and substance P (SP) on lung resistance (RL) and airway microvascular permeability were studied in anaesthetized guinea-pigs. 2. Single doses of inhaled NKA (3 x 10(-5), 1 x 10(-4), 3 x 10(-4) M; 45 breaths) and SP (1 x 10(-4), 3 x 10(-4), 1 x 10(-3); 45 breaths) caused a dose-dependent increase in both RL and airway microvascular leakage, assessed as extravasation of the albumin marker, Evans blue dye. 3. NKA at 1 x 10(-4) and 3 x 10(-4) M resulted in a significantly higher increase in RL than SP at the same doses. 4. Inhaled SP (3 x 10(-4) M; 45 breaths) caused significantly higher Evans blue dye extravasation in main bronchi and proximal intrapulmonary airways compared to the same dose of NKA. 5. Pretreatment with the specific inhibitor of neural endopeptidase (NEP24.11), phosphoramidon, caused an approximately 100 fold leftward shift of the RL responses to inhaled NKA and SP. 6. Phosphoramidon significantly potentiated both NKA- and SP-induced airway microvascular leakage at proximal intrapulmonary airways, but not at any other airway level. 7. Inhibition of NEP24.11 potentiate both the SP- or NKA-induced airflow obstruction to a larger extent than the induced airway microvascular leakage, suggesting that NEP24.11 is more important in the modulation of the airflow obstruction observed after these mediators.

  17. Nocturnal Oxygen Desaturation Index is Inversely Correlated with Airflow Limitation in Patients with Chronic Obstructive Pulmonary Disease.

    PubMed

    Tamai, Koji; Matsuoka, Hirofumi; Suzuki, Yujiro; Yoshimatsu, Harukazu; Masuya, Daiki; Nakashima, Nariyasu; Okada, Nobuhiko; Oda, Nao; Inoue, Sayaka; Koma, Yasuko; Otsuka, Akiko

    2016-01-01

    The concurrent diagnosis of chronic obstructive pulmonary disease (COPD) and sleep apnoea-hypopnoea syndrome (SAHS) (overlap syndrome), can contribute to worsening respiratory symptoms, but whether the severity of COPD is associated with co-morbid SAHS is unknown. We investigated whether the severity of COPD is associated with the complication of SAHS by examination of nocturnal oximetry as an alternative to polysomnography. Patients with COPD concurrently completed nocturnal oximetry, pulmonary function tests, a COPD assessment test, an Epworth sleepiness scale and a hospital anxiety and depression scale to evaluate the severity of COPD and possible concurrent presence of SAHS. We retrospectively analysed the data to assess correlation between the oxygen desaturation index (ODI) and each clinical variables and evaluated the predictors of ODI ≥ 15. This study included 103 patients (91 males, 88%) with a mean age of 72 ± 8 years and body mass index of 22 ± 3 kg/m(2). ODI was positively correlated with FEV1, FEV1/FVC and FEV1% predicted, which meant that ODI was inversely correlated with airflow limitation. Univariate logistic regression analysis revealed that FEV1% predicted and FEV1/FVC were predictors of ODI ≥ 15. ODI is inversely correlated with airflow limitation and milder COPD patients may have co-morbid SAHS.

  18. Chronic obstructive pulmonary disease with mild airflow limitation: current knowledge and proposal for future research - a consensus document from six scientific societies.

    PubMed

    Rossi, Andrea; Butorac-Petanjek, Bojana; Chilosi, Marco; Cosío, Borja G; Flezar, Matjaz; Koulouris, Nikolaos; Marin, José; Miculinic, Neven; Polese, Guido; Samaržija, Miroslav; Skrgat, Sabina; Vassilakopoulos, Theodoros; Vukić-Dugac, Andrea; Zakynthinos, Spyridon; Miravitlles, Marc

    2017-01-01

    Chronic obstructive pulmonary disease (COPD) is a leading cause of mortality and morbidity worldwide, with high and growing prevalence. Its underdiagnosis and hence under-treatment is a general feature across all countries. This is particularly true for the mild or early stages of the disease, when symptoms do not yet interfere with daily living activities and both patients and doctors are likely to underestimate the presence of the disease. A diagnosis of COPD requires spirometry in subjects with a history of exposure to known risk factors and symptoms. Postbronchodilator forced expiratory volume in 1 second (FEV 1 )/forced vital capacity <0.7 or less than the lower limit of normal confirms the presence of airflow limitation, the severity of which can be measured by FEV 1 % predicted: stage 1 defines COPD with mild airflow limitation, which means postbronchodilator FEV 1 ≥80% predicted. In recent years, an elegant series of studies has shown that "exclusive reliance on spirometry, in patients with mild airflow limitation, may result in underestimation of clinically important physiologic impairment". In fact, exercise tolerance, diffusing capacity, and gas exchange can be impaired in subjects at a mild stage of airflow limitation. Furthermore, growing evidence indicates that smokers without overt abnormal spirometry have respiratory symptoms and undergo therapy. This is an essential issue in COPD. In fact, on one hand, airflow limitation, even mild, can unduly limit the patient's physical activity, with deleterious consequences on quality of life and even survival; on the other hand, particularly in younger subjects, mild airflow limitation might coincide with the early stage of the disease. Therefore, we thought that it was worthwhile to analyze further and discuss this stage of "mild COPD". To this end, representatives of scientific societies from five European countries have met and developed this document to stimulate the attention of the scientific community

  19. Determining the optimal approach to identifying individuals with chronic obstructive pulmonary disease: The DOC study.

    PubMed

    Ronaldson, Sarah J; Dyson, Lisa; Clark, Laura; Hewitt, Catherine E; Torgerson, David J; Cooper, Brendan G; Kearney, Matt; Laughey, William; Raghunath, Raghu; Steele, Lisa; Rhodes, Rebecca; Adamson, Joy

    2018-06-01

    Early identification of chronic obstructive pulmonary disease (COPD) results in patients receiving appropriate management for their condition at an earlier stage in their disease. The determining the optimal approach to identifying individuals with chronic obstructive pulmonary disease (DOC) study was a case-finding study to enhance early identification of COPD in primary care, which evaluated the diagnostic accuracy of a series of simple lung function tests and symptom-based case-finding questionnaires. Current smokers aged 35 or more were invited to undertake a series of case-finding tools, which comprised lung function tests (specifically, spirometry, microspirometry, peak flow meter, and WheezoMeter) and several case-finding questionnaires. The effectiveness of these tests, individually or in combination, to identify small airways obstruction was evaluated against the gold standard of spirometry, with the quality of spirometry tests assessed by independent overreaders. The study was conducted with general practices in the Yorkshire and Humberside area, in the UK. Six hundred eighty-one individuals met the inclusion criteria, with 444 participants completing their study appointments. A total of 216 (49%) with good-quality spirometry readings were included in the analysis. The most effective case-finding tools were found to be the peak flow meter alone, the peak flow meter plus WheezoMeter, and microspirometry alone. In addition to the main analysis, where the severity of airflow obstruction was based on fixed ratios and percent of predicted values, sensitivity analyses were conducted by using lower limit of normal values. This research informs the choice of test for COPD identification; case-finding by use of the peak flow meter or microspirometer could be used routinely in primary care for suspected COPD patients. Only those testing positive to these tests would move on to full spirometry, thereby reducing unnecessary spirometric testing. © 2018 John Wiley

  20. Airflow obstruction was associated with elevation of brachial-ankle pulse wave velocity but not ankle-brachial index in aged patients with chronic obstructive pulmonary disease.

    PubMed

    Chen, Rui; He, Wanbing; Zhang, Kun; Zheng, Houzhen; Lin, Lin; Nie, Ruqiong; Wang, Jingfeng; Huang, Hui

    2015-09-01

    Both brachial-ankle pulse wave velocity (baPWV) and ankle-brachial index (ABI) are important predictors for cardiovascular disease (CVD). Patients with chronic obstructive pulmonary disease (COPD) are at high risk of CVD. But the association between airflow obstruction and baPWV or ABI was still unclear. The study was aimed to investigate the influencing factors on arterial stiffness in aged COPD patients. 67 aged patients with COPD and 67 age- and sex-matched controls without COPD were enrolled in this study. COPD patients were grouped into four groups according to the Global Initiative for Chronic Obstructive Lung Disease Guidelines (GOLD). Both baPWV and ABI were evaluated. Spirometry indices, blood pressure, smoking history and related laboratory parameters were also collected. Comparing with controls, all COPD patients had significantly higher baPWV (1933 ± 355 cm/s versus 1515 ± 256 cm/s, P < 0.001) but not ABI (P = 0.196). And baPWV values were significantly highest at GOLD stage 4. Forced expiratory volume in 1 s (FEV1) was the most significant factor influencing baPWV, after adjusting for age, systolic blood pressure and other traditional cardiovascular risk factors (β = -0.463, P = 0.014). Arterial stiffness was serious in aged patients with COPD. Spirometry index FEV1 was a possible important predictor for the severity of arterial stiffness of COPD patients. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  1. Development of a simple binary response questionnaire to identify airflow obstruction in a smoking population in Argentina.

    PubMed

    Bergna, Miguel A; García, Gabriel R; Alchapar, Ramon; Altieri, Hector; Casas, Juan C Figueroa; Larrateguy, Luis; Nannini, Luis J; Pascansky, Daniel; Grabre, Pedro; Zabert, Gustavo; Miravitlles, Marc

    2015-06-01

    The CODE questionnaire (COPD detection questionnaire), a simple, binary response scale (yes/no), screening questionnaire, was developed for the identification of patients with chronic obstructive pulmonary disease (COPD). We conducted a survey of 468 subjects with a smoking history in 10 public hospitals in Argentina. Patients with a previous diagnosis of COPD, asthma and other respiratory illness were excluded. Items that measured conceptual domains in terms of characteristics of symptoms, smoking history and demographics data were considered. 96 (20.5%) subjects had a diagnosis of COPD according to the 2010 Global Initiative for Chronic Obstructive Lung Disease strategy document. The variables selected for the final questionnaire were based on univariate and multivariate analyses and clinical criteria. Finally, we selected the presence or absence of six variables (age ≥50 years, smoking history ≥30 pack-years, male sex, chronic cough, chronic phlegm and dyspnoea). Of patients without any of these six variables (0 points), none had COPD. The ability of the CODE questionnaire to discriminate between subjects with and without COPD was good (the area under the receiver operating characteristic curve was 0.75). Higher scores were associated with a greater probability of COPD. The CODE questionnaire is a brief, accurate questionnaire that can identify smoking individuals likely to have COPD. Copyright ©ERS 2015.

  2. Chronic Obstructive Pulmonary Disease: Diagnosis and Management.

    PubMed

    Gentry, Shari; Gentry, Barry

    2017-04-01

    The diagnosis of chronic obstructive pulmonary disease (COPD) should be suspected in patients with risk factors (primarily a history of smoking) who report dyspnea at rest or with exertion, chronic cough with or without sputum production, or a history of wheezing. COPD may be suspected based on findings from the history and physical examination, but must be confirmed by spirometry to detect airflow obstruction. Findings that are most helpful to rule in COPD include a smoking history of more than 40 pack-years, a self-reported history of COPD, maximal laryngeal height, and age older than 45 years. The combination of three clinical variables-peak flow rate less than 350 L per minute, diminished breath sounds, and a smoking history of 30 pack-years or more-is another good clinical predictor, whereas the absence of all three of these signs essentially rules out airflow obstruction. Pharmacotherapy and smoking cessation are the mainstays of treatment, and pulmonary rehabilitation, long-term oxygen therapy, and surgery may be considered in select patients. Current guidelines recommend starting monotherapy with an inhaled bronchodilator, stepping up to combination therapy as needed, and/or adding inhaled corticosteroids as symptom severity and airflow obstruction progress.

  3. Corticosteroid therapy and airflow obstruction influence the bronchial microbiome, which is distinct from that of bronchoalveolar lavage in asthmatic airways

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denner, Darcy R.; Sangwan, Naseer; Becker, Julia B.

    The lung has a diverse microbiome that is modest in biomass. This microbiome differs in asthmatic patients compared with control subjects, but the effects of clinical characteristics on the microbial community composition and structure are not clear. OBJECTIVES: We examined whether the composition and structure of the lower airway microbiome correlated with clinical characteristics of chronic persistent asthma, including airflow obstruction, use of corticosteroid medications, and presence of airway eosinophilia. METHODS: DNA was extracted from endobronchial brushings and bronchoalveolar lavage fluid collected from 39 asthmatic patients and 19 control subjects, along with negative control samples. 16S rRNA V4 amplicon sequencingmore » was used to compare the relative abundance of bacterial genera with clinical characteristics. RESULTS: Differential feature selection analysis revealed significant differences in microbial diversity between brush and lavage samples from asthmatic patients and control subjects. Lactobacillus, Pseudomonas, and Rickettsia species were significantly enriched in samples from asthmatic patients, whereas Prevotella, Streptococcus, and Veillonella species were enriched in brush samples from control subjects. Generalized linear models on brush samples demonstrated oral corticosteroid use as an important factor affecting the relative abundance of the taxa that were significantly enriched in asthmatic patients. In addition, bacterial α-diversity in brush samples from asthmatic patients was correlated with FEV1 and the proportion of lavage eosinophils. CONCLUSION: The diversity and composition of the bronchial airway microbiome of asthmatic patients is distinct from that of nonasthmatic control subjects and influenced by worsening airflow obstruction and corticosteroid use. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.« less

  4. The Impact of Smoking on Airflow Limitation in Subjects with History of Asthma and Inactive Tuberculosis

    PubMed Central

    Kim, Hyun Jung; Baek, Seunghee; Kim, Hee Jin; Lee, Jae Seung; Oh, Yeon-Mok; Lee, Sang-Do; Lee, Sei Won

    2015-01-01

    Background Although smoking is the most important and modifiable cause of chronic obstructive pulmonary disease (COPD), other risk factors including asthma and tuberculosis (TB) are also associated. It is common for COPD patients to have more than one of these risk factors. The aims of this study were to determine the prevalence of airflow limitation (FEV1/FVC<0.7) according to the risk factors and to investigate their impact and interaction in airflow limitation. Methods From the Korean National Health and Nutrition Examination Survey between 2008 and 2012, we analyzed participants over 40 years of age by spirometry, chest radiograph and questionnaire about asthma and smoking history. Results Of 12,631 participants, 1,548 (12.3%) had airflow limitation. The prevalence of airflow limitation in smokers (≥10 pack-year), asthmatics, and those with inactive TB was 23.9%, 32.1%, and 33.6%. The prevalence increased with the number of risk factors: 86.1% had airflow limitation if they had all three risk factors. Impacts of inactive TB and asthma on airflow limitation were equivalent to 47 and 69 pack-years of smoking, respectively. Airflow limitation resulted from lower levels of smoking in those with inactive TB and asthma. A potential interaction between smoking and inactive tuberculosis in the development of airflow limitation was identified (p = 0.054). Conclusions Asthma and inactive TB lesions increase susceptibility to smoking in the development of airflow limitation. People with these risk factors should be seen as a major target population for anti-smoking campaigns to prevent COPD. PMID:25915938

  5. Effect of Nasal Obstruction on Continuous Positive Airway Pressure Treatment: Computational Fluid Dynamics Analyses

    PubMed Central

    Wakayama, Tadashi; Suzuki, Masaaki; Tanuma, Tadashi

    2016-01-01

    Objective Nasal obstruction is a common problem in continuous positive airway pressure (CPAP) therapy for obstructive sleep apnea and limits treatment compliance. The purpose of this study is to model the effects of nasal obstruction on airflow parameters under CPAP using computational fluid dynamics (CFD), and to clarify quantitatively the relation between airflow velocity and pressure loss coefficient in subjects with and without nasal obstruction. Methods We conducted an observational cross-sectional study of 16 Japanese adult subjects, of whom 9 had nasal obstruction and 7 did not (control group). Three-dimensional reconstructed models of the nasal cavity and nasopharynx with a CPAP mask fitted to the nostrils were created from each subject’s CT scans. The digital models were meshed with tetrahedral cells and stereolithography formats were created. CPAP airflow simulations were conducted using CFD software. Airflow streamlines and velocity contours in the nasal cavities and nasopharynx were compared between groups. Simulation models were confirmed to agree with actual measurements of nasal flow rate and with pressure and flow rate in the CPAP machine. Results Under 10 cmH2O CPAP, average maximum airflow velocity during inspiration was 17.6 ± 5.6 m/s in the nasal obstruction group but only 11.8 ± 1.4 m/s in the control group. The average pressure drop in the nasopharynx relative to inlet static pressure was 2.44 ± 1.41 cmH2O in the nasal obstruction group but only 1.17 ± 0.29 cmH2O in the control group. The nasal obstruction and control groups were clearly separated by a velocity threshold of 13.5 m/s, and pressure loss coefficient threshold of approximately 10.0. In contrast, there was no significant difference in expiratory pressure in the nasopharynx between the groups. Conclusion This is the first CFD analysis of the effect of nasal obstruction on CPAP treatment. A strong correlation between the inspiratory pressure loss coefficient and maximum airflow

  6. Chronic obstructive pulmonary disease with mild airflow limitation: current knowledge and proposal for future research – a consensus document from six scientific societies

    PubMed Central

    Rossi, Andrea; Butorac-Petanjek, Bojana; Chilosi, Marco; Cosío, Borja G; Flezar, Matjaz; Koulouris, Nikolaos; Marin, José; Miculinic, Neven; Polese, Guido; Samaržija, Miroslav; Skrgat, Sabina; Vassilakopoulos, Theodoros; Vukić-Dugac, Andrea; Zakynthinos, Spyridon; Miravitlles, Marc

    2017-01-01

    Chronic obstructive pulmonary disease (COPD) is a leading cause of mortality and morbidity worldwide, with high and growing prevalence. Its underdiagnosis and hence under-treatment is a general feature across all countries. This is particularly true for the mild or early stages of the disease, when symptoms do not yet interfere with daily living activities and both patients and doctors are likely to underestimate the presence of the disease. A diagnosis of COPD requires spirometry in subjects with a history of exposure to known risk factors and symptoms. Postbronchodilator forced expiratory volume in 1 second (FEV1)/forced vital capacity <0.7 or less than the lower limit of normal confirms the presence of airflow limitation, the severity of which can be measured by FEV1% predicted: stage 1 defines COPD with mild airflow limitation, which means postbronchodilator FEV1 ≥80% predicted. In recent years, an elegant series of studies has shown that “exclusive reliance on spirometry, in patients with mild airflow limitation, may result in underestimation of clinically important physiologic impairment”. In fact, exercise tolerance, diffusing capacity, and gas exchange can be impaired in subjects at a mild stage of airflow limitation. Furthermore, growing evidence indicates that smokers without overt abnormal spirometry have respiratory symptoms and undergo therapy. This is an essential issue in COPD. In fact, on one hand, airflow limitation, even mild, can unduly limit the patient’s physical activity, with deleterious consequences on quality of life and even survival; on the other hand, particularly in younger subjects, mild airflow limitation might coincide with the early stage of the disease. Therefore, we thought that it was worthwhile to analyze further and discuss this stage of “mild COPD”. To this end, representatives of scientific societies from five European countries have met and developed this document to stimulate the attention of the scientific

  7. Childhood measles contributes to post-bronchodilator airflow obstruction in middle-aged adults: A cohort study.

    PubMed

    Perret, Jennifer L; Matheson, Melanie C; Gurrin, Lyle C; Johns, David P; Burgess, John A; Thompson, Bruce R; Lowe, Adrian J; Markos, James; Morrison, Stephen S; McDonald, Christine F; Wood-Baker, Richard; Svanes, Cecilie; Thomas, Paul S; Hopper, John L; Giles, Graham G; Abramson, Michael J; Walters, E Haydn; Dharmage, Shyamali C

    2018-03-20

    Chronic obstructive pulmonary disease (COPD) has potential origins in childhood but an association between childhood measles and post-bronchodilator (BD) airflow obstruction (AO) has not yet been shown. We investigated whether childhood measles contributed to post-BD AO through interactions with asthma and/or smoking in a non-immunized middle-aged population. The population-based Tasmanian Longitudinal Health Study (TAHS) cohort born in 1961 (n = 8583) underwent spirometry in 1968 before immunization was introduced. A history of childhood measles infection was obtained from school medical records. During the fifth decade follow-up (n = 5729 responses), a subgroup underwent further lung function measurements (n = 1389). Relevant main associations and interactions by asthma and/or smoking on post-BD forced expiratory volume in 1 s/forced vital capacity (FEV 1 /FVC; continuous variable) and AO (FEV 1 /FVC < lower limit of normal) were estimated by multiple regression. Sixty-nine percent (n = 950) had a history of childhood measles. Childhood measles augmented the combined adverse effect of current clinical asthma and smoking at least 10 pack-years on post-BD FEV 1 /FVC ratio in middle age (z-score: -0.70 (95% CI: -1.1 to -0.3) vs -1.36 (-1.6 to -1.1), three-way interaction: P = 0.009), especially for those with childhood-onset asthma. For never- and ever-smokers of <10 pack-years who had current asthma symptoms, compared with those without childhood measles, paradoxically, the odds for post-BD AO was not significant in the presence of childhood measles (OR: 12.0 (95% CI: 3.4-42) vs 2.17 (0.9-5.3)). Childhood measles infection appears to compound the associations between smoking, current asthma and post-BD AO. Differences between asthma subgroups provide further insight into the complex aetiology of obstructive lung diseases for middle-aged adults. © 2018 Asian Pacific Society of Respirology.

  8. The use of combined thermal/pressure polyvinylidene fluoride film airflow sensor in polysomnography.

    PubMed

    Kryger, Meir; Eiken, Todd; Qin, Li

    2013-12-01

    The technologies recommended by the American Academy of Sleep Medicine (AASM) to monitor airflow in polysomnography (PSG) include the simultaneous monitoring of two physical variables: air temperature (for thermal airflow) and air pressure (for nasal pressure). To comply with airflow monitoring standards in the sleep lab setting thus often requires the patient to wear two sensors under the nose during testing. We hypothesized that a single combined thermal/pressure sensor using polyvinylidene fluoride (PVDF) film responsive to both airflow temperature and pressure would be effective in documenting abnormal breathing events during sleep. Sixty patients undergoing routine PSG testing to rule out obstructive sleep apnea at two different sleep laboratories were asked to wear a third PVDF airflow sensor in addition to the traditional thermal sensor and pressure sensor. Apnea and hypopnea events were scored by the sleep lab technologists using the AASM guidelines (CMS option) using the thermal sensor for apnea and the pressure sensor for hypopnea (scorer 1). The digital PSG data were also forwarded to an outside registered polysomnographic technologist for scoring of respiratory events detected in the PVDF airflow channels (scorer 2). The Pearson correlation coefficient, r, between apnea and hypopnea indices obtained using the AASM sensors and the combined PVDF sensor was almost unity for the four calculated indices: apnea-hypopnea index (0.990), obstructive apnea index (0.992), hypopnea index (0.958), and central apnea index (1.0). The slope of the four relationships was virtually unity and the coefficient of determination (r (2)) was also close to 1. The results of intraclass correlation coefficients (>0.95) and Bland-Altman plots also provide excellent agreement between the combined PVDF sensor and the AASM sensors. The indices used to calculate apnea severity obtained with the combined PVDF thermal and pressure sensor were equivalent to those obtained using AASM

  9. Chronic Bronchitis and Current Smoking Are Associated with More Goblet Cells in Moderate to Severe COPD and Smokers without Airflow Obstruction

    PubMed Central

    Kim, Victor; Oros, Michelle; Durra, Heba; Kelsen, Steven; Aksoy, Mark; Cornwell, William D.; Rogers, Thomas J.; Criner, Gerard J.

    2015-01-01

    Background Goblet cell hyperplasia is a classic but variable pathologic finding in COPD. Current literature shows that smoking is a risk factor for chronic bronchitis but the relationship of these clinical features to the presence and magnitude of large airway goblet cell hyperplasia has not been well described. We hypothesized that current smokers and chronic bronchitics would have more goblet cells than nonsmokers or those without chronic bronchitis (CB), independent of airflow obstruction. Methods We recruited 15 subjects with moderate to severe COPD, 12 healthy smokers, and 11 healthy nonsmokers. Six endobronchial mucosal biopsies per subject were obtained by bronchoscopy and stained with periodic acid Schiff-Alcian Blue. Goblet cell density (GCD) was quantified as goblet cell number per millimeter of basement membrane. Mucin volume density (MVD) was quantified as volume of mucin per unit area of basement membrane. Results Healthy smokers had a greater GCD and MVD than nonsmokers and COPD subjects. COPD subjects had a greater GCD than nonsmokers. When current smokers (healthy smokers and COPD current smokers, n = 19) were compared with all nonsmokers (nonsmoking controls and COPD ex-smokers, n = 19), current smokers had a greater GCD and MVD. When those with CB (n = 12) were compared to those without CB (n = 26), the CB group had greater GCD. This finding was also seen in those with CB in the COPD group alone. In multivariate analysis, current smoking and CB were significant predictors of GCD using demographics, lung function, and smoking pack years as covariates. All other covariates were not significant predictors of GCD or MVD. Conclusions Current smoking is associated with a more goblet cell hyperplasia and number, and CB is associated with more goblet cells, independent of the presence of airflow obstruction. This provides clinical and pathologic correlation for smokers with and without COPD. PMID:25646735

  10. Three-Dimensional Numerical Simulation of Airflow in Nasopharynx.

    NASA Astrophysics Data System (ADS)

    Shome, Biswadip; Wang, Lian-Ping; Santare, Michael H.; Szeri, Andras Z.; Prasad, Ajay K.; Roberts, David

    1996-11-01

    A three-dimensional numerical simulation of airflow in nasopharynx (from the soft palate to the epiglottis) was conducted, using anatomically accurate model and finite element method, to study the influence of flow characteristics on obstructive sleep apnea (OSA). The results showed that the pressure drop in the nasopharynx is in the range 200-500 Pa. Ten different nasopharynx geometries resulting from three OSA treatment therapies (CPAP, mandibular repositioning devices, and surgery) were compared. The results confirmed that the airflow in the nasopharynx lies in the transitional flow regime and thus, a subtle change in the morphology caused by these treatment therapies has a large effect on the airflow. The onset of turbulence can cause as much as 40% of increase in pressure drop. For the transitional flow regime, the k-ɛ turbulence model was found to be the most appropriate model, when compared to the mixing length and the k-ω model, as it correctly reproduces the limiting laminar behavior. In addition, the pressure drop increased approximately as the square of the volumetric flow rate. Supported by NIH.

  11. Non-emphysematous chronic obstructive pulmonary disease is associated with diabetes mellitus.

    PubMed

    Hersh, Craig P; Make, Barry J; Lynch, David A; Barr, R Graham; Bowler, Russell P; Calverley, Peter M A; Castaldi, Peter J; Cho, Michael H; Coxson, Harvey O; DeMeo, Dawn L; Foreman, Marilyn G; Han, MeiLan K; Harshfield, Benjamin J; Hokanson, John E; Lutz, Sharon; Ramsdell, Joe W; Regan, Elizabeth A; Rennard, Stephen I; Schroeder, Joyce D; Sciurba, Frank C; Steiner, Robert M; Tal-Singer, Ruth; van Beek, Edwin; Silverman, Edwin K; Crapo, James D

    2014-10-24

    Chronic obstructive pulmonary disease (COPD) has been classically divided into blue bloaters and pink puffers. The utility of these clinical subtypes is unclear. However, the broader distinction between airway-predominant and emphysema-predominant COPD may be clinically relevant. The objective was to define clinical features of emphysema-predominant and non-emphysematous COPD patients. Current and former smokers from the Genetic Epidemiology of COPD Study (COPDGene) had chest computed tomography (CT) scans with quantitative image analysis. Emphysema-predominant COPD was defined by low attenuation area at -950 Hounsfield Units (LAA-950) ≥10%. Non-emphysematous COPD was defined by airflow obstruction with minimal to no emphysema (LAA-950 < 5%). Out of 4197 COPD subjects, 1687 were classified as emphysema-predominant and 1817 as non-emphysematous; 693 had LAA-950 between 5-10% and were not categorized. Subjects with emphysema-predominant COPD were older (65.6 vs 60.6 years, p < 0.0001) with more severe COPD based on airflow obstruction (FEV1 44.5 vs 68.4%, p < 0.0001), greater exercise limitation (6-minute walk distance 1138 vs 1331 ft, p < 0.0001) and reduced quality of life (St. George's Respiratory Questionnaire score 43 vs 31, p < 0.0001). Self-reported diabetes was more frequent in non-emphysematous COPD (OR 2.13, p < 0.001), which was also confirmed using a strict definition of diabetes based on medication use. The association between diabetes and non-emphysematous COPD was replicated in the ECLIPSE study. Non-emphysematous COPD, defined by airflow obstruction with a paucity of emphysema on chest CT scan, is associated with an increased risk of diabetes. COPD patients without emphysema may warrant closer monitoring for diabetes, hypertension, and hyperlipidemia and vice versa. Clinicaltrials.gov identifiers: COPDGene NCT00608764, ECLIPSE NCT00292552.

  12. Frequency of self-reported COPD exacerbation and airflow obstruction in five Latin American cities: the Proyecto Latinoamericano de Investigacion en Obstruccion Pulmonar (PLATINO) study.

    PubMed

    Montes de Oca, Maria; Tálamo, Carlos; Halbert, Ronald J; Perez-Padilla, Rogelio; Lopez, Maria Victorina; Muiño, Adriana; Jardim, José Roberto B; Valdivia, Gonzalo; Pertuzé, Julio; Moreno, Dolores; Menezes, Ana Maria B

    2009-07-01

    Recurrent exacerbations are common in COPD patients. Limited information exists regarding exacerbation frequency in COPD patients from epidemiologic studies. We examined the frequency of self-reported exacerbations and the factors influencing exacerbation frequency among COPD patients in a population-based study conducted in Latin America. We used a post-bronchodilator FEV(1)/FVC ratio of < 0.70 to define COPD. Exacerbation was self-reported and defined by symptoms (deterioration of breathing symptoms that affected usual daily activities or caused missed work). Spirometry was performed in 5,314 subjects. There were 759 subjects with airflow limitation; of these, 18.2% reported ever having had an exacerbation, 7.9% reported having an exacerbation, and 6.2% reported having an exacerbation requiring at least a doctor visit within the past year. The proportion of individuals with an exacerbation significantly increased by Global Initiative for Chronic Obstructive Lung Disease (GOLD) stages, from 4.2% in stage 1 to 28.9% in stages 3 and 4. The self-reported exacerbation rate was 0.58 exacerbations per year. The rate of exacerbations requiring at least a doctor visit and length of stay in hospital due to exacerbations also increased as COPD severity progressed. The factors associated with having an exacerbation in the past year were dyspnea, prior asthma diagnosis, receiving any respiratory therapy, and disease severity of GOLD stages 3 and 4. The proportion of individuals with airflow limitation and self-reported exacerbation increases as the disease severity progresses. Dyspnea, prior asthma diagnosis, receiving any respiratory therapy, and more severe obstruction were significantly associated with having an exacerbation in the past year.

  13. Leukotriene E4 induces airflow obstruction and mast cell activation through the cysteinyl leukotriene type 1 receptor.

    PubMed

    Lazarinis, Nikolaos; Bood, Johan; Gomez, Cristina; Kolmert, Johan; Lantz, Ann-Sofie; Gyllfors, Pär; Davis, Andy; Wheelock, Craig E; Dahlén, Sven-Erik; Dahlén, Barbro

    2018-03-05

    Leukotriene (LT) E 4 is the final active metabolite among the cysteinyl leukotrienes (CysLTs). Animal studies have identified a distinct LTE 4 receptor, suggesting that current cysteinyl leukotriene type 1 (CysLT 1 ) receptor antagonists can provide incomplete inhibition of CysLT responses. We tested this hypothesis by assessing the influence of the CysLT 1 antagonist montelukast on responses induced by means of inhalation of LTE 4 in asthmatic patients. Fourteen patients with mild intermittent asthma and 2 patients with aspirin-exacerbated respiratory disease received 20 mg of montelukast twice daily and placebo for 5 to 7 days in a randomized, double-blind, crossover study (NCT01841164). The PD 20 value was determined at the end of each treatment period based on an increasing dose challenge. Measurements included lipid mediators in urine and sputum cells 4 hours after LTE 4 challenge. Montelukast completely blocked LTE 4 -induced bronchoconstriction. Despite tolerating an at least 10 times higher dose of LTE 4 after montelukast, there was no difference in the percentage of eosinophils in sputum. Urinary excretion of all major lipid mediators increased after LTE 4 inhalation. Montelukast blocked release of the mast cell product prostaglandin (PG) D 2 , as well as release of PGF 2α and thromboxane (Tx) A 2 , but not increased excretion of PGE 2 and its metabolites or isoprostanes. LTE 4 induces airflow obstruction and mast cell activation through the CysLT 1 receptor. Copyright © 2018 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  14. Risk factors associated with persistent airflow limitation in severe or difficult-to-treat asthma: insights from the TENOR study.

    PubMed

    Lee, June H; Haselkorn, Tmirah; Borish, Larry; Rasouliyan, Lawrence; Chipps, Bradley E; Wenzel, Sally E

    2007-12-01

    The Epidemiology and Natural History of Asthma: Outcomes and Treatment Regimens study is among the largest to assess persistent airflow limitation and the first to evaluate a wide range of potential risk factors in high-risk patients with severe or difficult-to-treat asthma. A better understanding is needed regarding factors associated with persistent airway obstruction; this study was performed to determine demographic and clinical characteristics associated with persistent airflow limitation. Data from adult patients (>or= 18 years old) with severe or difficult-to-treat asthma were evaluated. Patients with COPD, obesity with a restrictive respiratory pattern, or a >or= 30 pack-year history of smoking were excluded. Patients with persistent airflow limitation (postbronchodilator FEV1/FVC ratio identified factors independently associated with persistent airflow limitation. Of 1,017 patients, 612 patients (60%) showed evidence of persistent airflow limitation. Risk factors were as follows: older age (odds ratio [OR] per 10 years, 1.4; 95% confidence interval [CI], 1.3 to 1.6); male gender (OR, 4.5; 95% CI, 2.3 to 8.5); black ethnicity (OR, 2.2; 95% CI, 1.3 to 3.8); current or past smoking (OR, 3.9; 95% CI, 1.8 to 8.6; and OR, 1.6; 95% CI, 1.2 to 2.3, respectively); aspirin sensitivity (OR, 1.5; 95% CI, 1.0 to 2.4); and longer asthma duration (OR per 10 years, 1.6; 95% CI, 1.4 to 1.8). Protective factors were Hispanic ethnicity, higher education, family history of atopic dermatitis, pet(s) in the home, and dust sensitivity. Persistent airflow limitation is prevalent in patients with severe or difficult-to-treat asthma and is associated with identifiable clinical and demographic characteristics.

  15. Occupational exposures to solvents and metals are associated with fixed airflow obstruction.

    PubMed

    Alif, Sheikh M; Dharmage, Shyamali C; Benke, Geza; Dennekamp, Martine; Burgess, John A; Perret, Jennifer L; Lodge, Caroline J; Morrison, Stephen; Johns, David P; Giles, Graham G; Gurrin, Lyle C; Thomas, Paul S; Hopper, John L; Wood-Baker, Richard; Thompson, Bruce R; Feather, Iain H; Vermeulen, Roel; Kromhout, Hans; Walters, E Haydn; Abramson, Michael J; Matheson, Melanie C

    2017-11-01

    Objectives This study investigated the associations between occupational exposures to solvents and metals and fixed airflow obstruction (AO) using post-bronchodilator spirometry. Methods We included 1335 participants from the 2002-2008 follow-up of the Tasmanian Longitudinal Health Study. Ever-exposure and cumulative exposure-unit (EU) years were calculated using the ALOHA plus job exposure matrix (JEM). Fixed AO was defined as post-bronchodilator forced expiratory volume in one second (FEV1)/forced vital capacity (FVC) <0.7 and FEV 1 /FVC

  16. The Contribution of Small Airway Obstruction to the Pathogenesis of Chronic Obstructive Pulmonary Disease.

    PubMed

    Hogg, James C; Paré, Peter D; Hackett, Tillie-Louise

    2017-04-01

    The hypothesis that the small conducting airways were the major site of obstruction to airflow in normal lungs was introduced by Rohrer in 1915 and prevailed until Weibel introduced a quantitative method of studying lung anatomy in 1963. Green repeated Rohrer's calculations using Weibels new data in 1965 and found that the smaller conducting airways offered very little resistance to airflow. This conflict was resolved by seminal experiments conducted by Macklem and Mead in 1967, which confirmed that a small proportion of the total lower airways resistance is attributable to small airways <2 mm in diameter. Shortly thereafter, Hogg, Macklem, and Thurlbeck used this technique to show that small airways become the major site of obstruction in lungs affected by emphysema. These and other observations led Mead to write a seminal editorial in 1970 that postulated the small airways are a silent zone within normal lungs where disease can accumulate over many years without being noticed. This review provides a progress report since the 1970s on methods for detecting chronic obstructive pulmonary disease, the structural nature of small airways' disease, and the cellular and molecular mechanisms that are thought to underlie its pathogenesis. Copyright © 2017 the American Physiological Society.

  17. Investigation of the effects of miniscrew-assisted rapid palatal expansion on airflow in the upper airway of an adult patient with obstructive sleep apnea syndrome using computational fluid-structure interaction analysis

    PubMed Central

    Hur, Jae-Sik; Kim, Hyoung-Ho; Choi, Jin-Young; Suh, Sang-Ho

    2017-01-01

    Objective The objective of this study was to investigate the effects of miniscrew-assisted rapid palatal expansion (MARPE) on changes in airflow in the upper airway (UA) of an adult patient with obstructive sleep apnea syndrome (OSAS) using computational fluid-structure interaction analysis. Methods Three-dimensional UA models fabricated from cone beam computed tomography images obtained before (T0) and after (T1) MARPE in an adult patient with OSAS were used for computational fluid dynamics with fluid-structure interaction analysis. Seven and nine cross-sectional planes (interplane distance of 10 mm) in the nasal cavity (NC) and pharynx, respectively, were set along UA. Changes in the cross-sectional area and changes in airflow velocity and pressure, node displacement, and total resistance at maximum inspiration (MI), rest, and maximum expiration (ME) were investigated at each plane after MARPE. Results The cross-sectional areas at most planes in NC and the upper half of the pharynx were significantly increased at T1. Moreover, airflow velocity decreased in the anterior NC at MI and ME and in the nasopharynx and oropharynx at MI. The decrease in velocity was greater in NC than in the pharynx. The airflow pressure in the anterior NC and entire pharynx exhibited a decrease at T1. The amount of node displacement in NC and the pharynx was insignificant at both T0 and T1. Absolute values for the total resistance at MI, rest, and ME were lower at T1 than at T0. Conclusions MARPE improves airflow and decreases resistance in UA; therefore, it may be an effective treatment modality for adult patients with moderate OSAS. PMID:29090123

  18. Effect of Sleeping Position on Upper Airway Patency in Obstructive Sleep Apnea Is Determined by the Pharyngeal Structure Causing Collapse

    PubMed Central

    Genta, Pedro R.; Sands, Scott A.; Azarbazin, Ali; de Melo, Camila; Taranto-Montemurro, Luigi; White, David P.; Wellman, Andrew

    2017-01-01

    Abstract Objectives: In some patients, obstructive sleep apnea (OSA) can be resolved with improvement in pharyngeal patency by sleeping lateral rather than supine, possibly as gravitational effects on the tongue are relieved. Here we tested the hypothesis that the improvement in pharyngeal patency depends on the anatomical structure causing collapse, with patients with tongue-related obstruction and epiglottic collapse exhibiting preferential improvements. Methods: Twenty-four OSA patients underwent upper airway endoscopy during natural sleep to determine the pharyngeal structure associated with obstruction, with simultaneous recordings of airflow and pharyngeal pressure. Patients were grouped into three categories based on supine endoscopy: Tongue-related obstruction (posteriorly located tongue, N = 10), non-tongue related obstruction (collapse due to the palate or lateral walls, N = 8), and epiglottic collapse (N = 6). Improvement in pharyngeal obstruction was quantified using the change in peak inspiratory airflow and minute ventilation lateral versus supine. Results: Contrary to our hypothesis, patients with tongue-related obstruction showed no improvement in airflow, and the tongue remained posteriorly located while lateral. Patients without tongue involvement showed modest improvement in airflow (peak flow increased 0.07 L/s and ventilation increased 1.5 L/min). Epiglottic collapse was virtually abolished with lateral positioning and ventilation increased by 45% compared to supine position. Conclusions: Improvement in pharyngeal patency with sleeping position is structure specific, with profound improvements seen in patients with epiglottic collapse, modest effects in those without tongue involvement and—unexpectedly—no effect in those with tongue-related obstruction. Our data refute the notion that the tongue falls back into the airway during sleep via gravitational influences. PMID:28329099

  19. Relationships among smoking habits, airflow limitations, and metabolic abnormalities in school workers.

    PubMed

    Horie, Masafumi; Noguchi, Satoshi; Tanaka, Wakae; Goto, Yasushi; Yoshihara, Hisanao; Kawakami, Masaki; Suzuki, Masaru; Sakamoto, Yoshio

    2013-01-01

    Chronic obstructive pulmonary disease is caused mainly by habitual smoking and is common among elderly individuals. It involves not only airflow limitation but also metabolic disorders, leading to increased cardiovascular morbidity and mortality. We evaluated relationships among smoking habits, airflow limitation, and metabolic abnormalities. Between 2001 and 2008, 15,324 school workers (9700 males, 5624 females; age: ≥ 30 years) underwent medical checkups, including blood tests and spirometry. They also responded to a questionnaire on smoking habits and medical history. Airflow limitation was more prevalent in current smokers than in ex-smokers and never-smokers in men and women. The frequency of hypertriglyceridemia was higher in current smokers in all age groups, and those of low high-density-lipoprotein cholesterolemia and diabetes mellitus were higher in current smokers in age groups ≥ 40 s in men, but not in women. There were significant differences in the frequencies of metabolic abnormalities between subjects with airflow limitations and those without in women, but not in men. Smoking index was an independent factor associated with increased frequencies of hypertriglyceridemia (OR 1.015; 95% CI: 1.012-1.018; p<0.0001) and low high-density-lipoprotein cholesterolemia (1.013; 1.010-1.016; p<0.0001) in men. Length of smoking cessation was an independent factor associated with a decreased frequency of hypertriglyceridemia (0.984; 0.975-0.994; p = 0.007). Habitual smoking causes high incidences of airflow limitation and metabolic abnormalities. Women, but not men, with airflow limitation had higher frequencies of metabolic abnormalities.

  20. Effects of miso- and mesoscale obstructions on PAM winds obtained during project NIMROD. [Portable Automated Mesonet

    NASA Technical Reports Server (NTRS)

    Fujita, T. T.; Wakimoto, R. M.

    1982-01-01

    Data from 27 PAM (Portable Automated Mesonet) stations, operational as a phase of project NIMROD (Northern Illinois Meteorological Research on Downburst), are presented. It was found that PAM-measured winds are influenced by the mesoscale obstruction of the Chicago metropolitan area, as well as by the misoscale obstruction of identified trees and buildings. The mesoscale obstruction was estimated within the range of near zero to 50%, increasing toward the city limits, while the misoscale obstruction was estimated as being as large as 58% near obstructing trees which were empirically calculated to cause a wind speed deficit 50-80 times their height. Despite a statistical analysis based on one-million PAM winds, wind speed and stability transmission factors could not be accurately calculated; thus, in order to calculate the airflow free from obstacle, PAM-measured winds must be corrected.

  1. Whole exome sequencing identifies novel candidate genes that modify chronic obstructive pulmonary disease susceptibility.

    PubMed

    Bruse, Shannon; Moreau, Michael; Bromberg, Yana; Jang, Jun-Ho; Wang, Nan; Ha, Hongseok; Picchi, Maria; Lin, Yong; Langley, Raymond J; Qualls, Clifford; Klensney-Tait, Julia; Zabner, Joseph; Leng, Shuguang; Mao, Jenny; Belinsky, Steven A; Xing, Jinchuan; Nyunoya, Toru

    2016-01-07

    Chronic obstructive pulmonary disease (COPD) is characterized by an irreversible airflow limitation in response to inhalation of noxious stimuli, such as cigarette smoke. However, only 15-20 % smokers manifest COPD, suggesting a role for genetic predisposition. Although genome-wide association studies have identified common genetic variants that are associated with susceptibility to COPD, effect sizes of the identified variants are modest, as is the total heritability accounted for by these variants. In this study, an extreme phenotype exome sequencing study was combined with in vitro modeling to identify COPD candidate genes. We performed whole exome sequencing of 62 highly susceptible smokers and 30 exceptionally resistant smokers to identify rare variants that may contribute to disease risk or resistance to COPD. This was a cross-sectional case-control study without therapeutic intervention or longitudinal follow-up information. We identified candidate genes based on rare variant analyses and evaluated exonic variants to pinpoint individual genes whose function was computationally established to be significantly different between susceptible and resistant smokers. Top scoring candidate genes from these analyses were further filtered by requiring that each gene be expressed in human bronchial epithelial cells (HBECs). A total of 81 candidate genes were thus selected for in vitro functional testing in cigarette smoke extract (CSE)-exposed HBECs. Using small interfering RNA (siRNA)-mediated gene silencing experiments, we showed that silencing of several candidate genes augmented CSE-induced cytotoxicity in vitro. Our integrative analysis through both genetic and functional approaches identified two candidate genes (TACC2 and MYO1E) that augment cigarette smoke (CS)-induced cytotoxicity and, potentially, COPD susceptibility.

  2. Classification of Airflow Limitation Based on z-Score Underestimates Mortality in Patients with Chronic Obstructive Pulmonary Disease.

    PubMed

    Tejero, Elena; Prats, Eva; Casitas, Raquel; Galera, Raúl; Pardo, Paloma; Gavilán, Adelaida; Martínez-Cerón, Elisabet; Cubillos-Zapata, Carolina; Del Peso, Luis; García-Río, Francisco

    2017-08-01

    Global Lung Function Initiative recommends reporting lung function measures as z-score, and a classification of airflow limitation (AL) based on this parameter has recently been proposed. To evaluate the prognostic capacity of the AL classifications based on z-score or percentage predicted of FEV 1 in patients with chronic obstructive pulmonary disease (COPD). A cohort of 2,614 patients with COPD recruited outside the hospital setting was examined after a mean (± SD) of 57 ± 13 months of follow-up, totaling 10,322 person-years. All-cause mortality was analyzed, evaluating the predictive capacity of several AL staging systems. Based on Global Initiative for Chronic Obstructive Lung Disease guidelines, 461 patients (17.6%) had mild, 1,452 (55.5%) moderate, 590 (22.6%) severe, and 111 (4.2%) very severe AL. According to z-score classification, 66.3% of patients remained with the same severity, whereas 23.7% worsened and 10.0% improved. Unlike other staging systems, patients with severe AL according to z-score had higher mortality than those with very severe AL (increase of risk by 5.2 and 3.9 times compared with mild AL, respectively). The predictive capacity for 5-year survival was slightly higher for FEV 1 expressed as percentage of predicted than as z-score (area under the curve: 0.714-0.760 vs. 0.649-0.708, respectively). A severity-dependent relationship between AL grades by z-score and mortality was only detected in patients younger than age 60 years. In patients with COPD, the AL classification based on z-score predicts worse mortality than those based on percentage of predicted. It is possible that the z-score underestimates AL severity in patients older than 60 years of age with severe functional impairment.

  3. Role of BMI, airflow obstruction, St George's Respiratory Questionnaire and age index in prognostication of Asian COPD.

    PubMed

    Chan, Hiang Ping; Mukhopadhyay, Amartya; Chong, Pauline Lee Poh; Chin, Sally; Wong, Xue Yun; Ong, Venetia; Chan, Yiong Huak; Lim, Tow Keang; Phua, Jason

    2017-01-01

    COPD is a complex condition with a heavy burden of disease. Many multidimensional tools have been studied for their prognostic utility but none has been universally adopted as each has its own limitations. We hypothesize that a multidimensional tool examining four domains, health-related quality of life, disease severity, systemic effects of disease and patient factors, would better categorize and prognosticate these patients. We first evaluated 300 patients and found four factors that predicted mortality: BMI, airflow obstruction, St George's Respiratory Questionnaire and age (BOSA). A 10-point index (BOSA index) was constructed and prospectively validated in a cohort of 772 patients with all-cause mortality as the primary outcome. Patients were categorized into their respective BOSA quartile group based on their BOSA score. Multivariate survival analyses and receiver operator characteristic (ROC) curves were used to assess the BOSA index. Patients in BOSA Group 4 were at higher risk of death compared with their counterparts in Group 1 (hazard ratio (HR): 0.29, 95% CI: 0.16-0.51, P < 0.001) and Group 2 (HR: 0.53, 95% CI: 0.34-0.82, P = 0.005). Race and gender did not affect mortality. The area under the ROC curve for BOSA index was 0.690 ± 0.025 while that for Global Initiative for Chronic Obstructive Lung Disease (GOLD) 2011 was 0.641 ± 0.025 (P = 0.17). The BOSA index predicts mortality well and it has at least similar prognostic utility as GOLD 2011 in Asian patients. The BOSA index is a simple tool that does not require complex equipment or testing. It has the potential to be used widely. © 2016 Asian Pacific Society of Respirology.

  4. Validation of polyvinylidene fluoride nasal sensor to assess nasal obstruction in comparison with subjective technique.

    PubMed

    Roopa Manjunatha, G; Mahapatra, D Roy; Prakash, Surya; Rajanna, K

    2015-01-01

    The aim of this study is to validate the applicability of the PolyVinyliDene Fluoride (PVDF) nasal sensor to assess the nasal airflow, in healthy subjects and patients with nasal obstruction and to correlate the results with the score of Visual Analogue Scale (VAS). PVDF nasal sensor and VAS measurements were carried out in 50 subjects (25-healthy subjects and 25 patients). The VAS score of nasal obstruction and peak-to-peak amplitude (Vp-p) of nasal cycle measured by PVDF nasal sensors were analyzed for right nostril (RN) and left nostril (LN) in both the groups. Spearman's rho correlation was calculated. The relationship between PVDF nasal sensor measurements and severity of nasal obstruction (VAS score) were assessed by ANOVA. In healthy group, the measurement of nasal airflow by PVDF nasal sensor for RN and LN were found to be 51.14±5.87% and 48.85±5.87%, respectively. In patient group, PVDF nasal sensor indicated lesser nasal airflow in the blocked nostrils (RN: 23.33±10.54% and LN: 32.24±11.54%). Moderate correlation was observed in healthy group (r=-0.710, p<0.001 for RN and r=-0.651, p<0.001 for LN), and moderate to strong correlation in patient group (r=-0.751, p<0.01 for RN and r=-0.885, p<0.0001 for LN). PVDF nasal sensor method is a newly developed technique for measuring the nasal airflow. Moderate to strong correlation was observed between PVDF nasal sensor data and VAS scores for nasal obstruction. In our present study, PVDF nasal sensor technique successfully differentiated between healthy subjects and patients with nasal obstruction. Additionally, it can also assess severity of nasal obstruction in comparison with VAS. Thus, we propose that the PVDF nasal sensor technique could be used as a new diagnostic method to evaluate nasal obstruction in routine clinical practice. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Obstructive lung disease as a complication in post pulmonary TB

    NASA Astrophysics Data System (ADS)

    Tarigan, A. P.; Pandia, P.; Eyanoer, P.; Tina, D.; Pratama, R.; Fresia, A.; Tamara; Silvanna

    2018-03-01

    The case of post TB is a problem that arises in the community. Pulmonary tuberculosis (TB) can affect lung function. Therefore, we evaluated impaired pulmonary function in subjects with diagnosed prior pulmonary TB. A Case Series study, pulmonary function test was performed in subjects with a history of pulmonary tuberculosis; aged ≥18 years were included. Exclusion criteria was a subject who had asthma, obesity, abnormal thorax and smoking history. We measured FEV1 and FVC to evaluate pulmonary function. Airflow obstruction was FEV1/FVC%<75 and restriction was FVC<80% according to Indonesia’s pneumomobile project. This study was obtained from 23 patients with post pulmonary TB, 5 subjects (23%) had airflow obstruction with FEV1/FVC% value <75%, 15 subjects (71.4%) had abnormalities restriction with FVC value <80% and 3 subjects (5.6%) had normal lung function. Obstructive lung disease is one of the complications of impaired lung function in post pulmonary TB.

  6. Effect of Sleeping Position on Upper Airway Patency in Obstructive Sleep Apnea Is Determined by the Pharyngeal Structure Causing Collapse.

    PubMed

    Marques, Melania; Genta, Pedro R; Sands, Scott A; Azarbazin, Ali; de Melo, Camila; Taranto-Montemurro, Luigi; White, David P; Wellman, Andrew

    2017-03-01

    In some patients, obstructive sleep apnea (OSA) can be resolved with improvement in pharyngeal patency by sleeping lateral rather than supine, possibly as gravitational effects on the tongue are relieved. Here we tested the hypothesis that the improvement in pharyngeal patency depends on the anatomical structure causing collapse, with patients with tongue-related obstruction and epiglottic collapse exhibiting preferential improvements. Twenty-four OSA patients underwent upper airway endoscopy during natural sleep to determine the pharyngeal structure associated with obstruction, with simultaneous recordings of airflow and pharyngeal pressure. Patients were grouped into three categories based on supine endoscopy: Tongue-related obstruction (posteriorly located tongue, N = 10), non-tongue related obstruction (collapse due to the palate or lateral walls, N = 8), and epiglottic collapse (N = 6). Improvement in pharyngeal obstruction was quantified using the change in peak inspiratory airflow and minute ventilation lateral versus supine. Contrary to our hypothesis, patients with tongue-related obstruction showed no improvement in airflow, and the tongue remained posteriorly located while lateral. Patients without tongue involvement showed modest improvement in airflow (peak flow increased 0.07 L/s and ventilation increased 1.5 L/min). Epiglottic collapse was virtually abolished with lateral positioning and ventilation increased by 45% compared to supine position. Improvement in pharyngeal patency with sleeping position is structure specific, with profound improvements seen in patients with epiglottic collapse, modest effects in those without tongue involvement and-unexpectedly-no effect in those with tongue-related obstruction. Our data refute the notion that the tongue falls back into the airway during sleep via gravitational influences. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved

  7. Relationships among Smoking Habits, Airflow Limitations, and Metabolic Abnormalities in School Workers

    PubMed Central

    Horie, Masafumi; Noguchi, Satoshi; Tanaka, Wakae; Goto, Yasushi; Yoshihara, Hisanao; Kawakami, Masaki; Suzuki, Masaru; Sakamoto, Yoshio

    2013-01-01

    Background Chronic obstructive pulmonary disease is caused mainly by habitual smoking and is common among elderly individuals. It involves not only airflow limitation but also metabolic disorders, leading to increased cardiovascular morbidity and mortality. Objective We evaluated relationships among smoking habits, airflow limitation, and metabolic abnormalities. Methods Between 2001 and 2008, 15,324 school workers (9700 males, 5624 females; age: ≥30 years) underwent medical checkups, including blood tests and spirometry. They also responded to a questionnaire on smoking habits and medical history. Results Airflow limitation was more prevalent in current smokers than in ex-smokers and never-smokers in men and women. The frequency of hypertriglyceridemia was higher in current smokers in all age groups, and those of low high-density-lipoprotein cholesterolemia and diabetes mellitus were higher in current smokers in age groups ≥ 40 s in men, but not in women. There were significant differences in the frequencies of metabolic abnormalities between subjects with airflow limitations and those without in women, but not in men. Smoking index was an independent factor associated with increased frequencies of hypertriglyceridemia (OR 1.015; 95% CI: 1.012–1.018; p<0.0001) and low high-density-lipoprotein cholesterolemia (1.013; 1.010–1.016; p<0.0001) in men. Length of smoking cessation was an independent factor associated with a decreased frequency of hypertriglyceridemia (0.984; 0.975–0.994; p = 0.007). Conclusions Habitual smoking causes high incidences of airflow limitation and metabolic abnormalities. Women, but not men, with airflow limitation had higher frequencies of metabolic abnormalities. PMID:24312268

  8. DNAH5 is associated with total lung capacity in chronic obstructive pulmonary disease.

    PubMed

    Lee, Jin Hwa; McDonald, Merry-Lynn N; Cho, Michael H; Wan, Emily S; Castaldi, Peter J; Hunninghake, Gary M; Marchetti, Nathaniel; Lynch, David A; Crapo, James D; Lomas, David A; Coxson, Harvey O; Bakke, Per S; Silverman, Edwin K; Hersh, Craig P

    2014-08-20

    Chronic obstructive pulmonary disease (COPD) is characterized by expiratory flow limitation, causing air trapping and lung hyperinflation. Hyperinflation leads to reduced exercise tolerance and poor quality of life in COPD patients. Total lung capacity (TLC) is an indicator of hyperinflation particularly in subjects with moderate-to-severe airflow obstruction. The aim of our study was to identify genetic variants associated with TLC in COPD. We performed genome-wide association studies (GWASs) in white subjects from three cohorts: the COPDGene Study; the Evaluation of COPD Longitudinally to Identify Predictive Surrogate Endpoints (ECLIPSE); and GenKOLS (Bergen, Norway). All subjects were current or ex-smokers with at least moderate airflow obstruction, defined by a ratio of forced expiratory volume in 1 second to forced vital capacity (FEV1/FVC) <0.7 and FEV1 < 80% predicted on post-bronchodilator spirometry. TLC was calculated by using volumetric computed tomography scans at full inspiration (TLCCT). Genotyping in each cohort was completed, with statistical imputation of additional markers. To find genetic variants associated with TLCCT, linear regression models were used, with adjustment for age, sex, pack-years of smoking, height, and principal components for genetic ancestry. Results were summarized using fixed-effect meta-analysis. Analysis of a total of 4,543 COPD subjects identified one genome-wide significant locus on chromosome 5p15.2 (rs114929486, β = 0.42L, P = 4.66 × 10-8). In COPD, TLCCT was associated with a SNP in dynein, axonemal, heavy chain 5 (DNAH5), a gene in which genetic variants can cause primary ciliary dyskinesia. DNAH5 could have an effect on hyperinflation in COPD.

  9. Upper Airway Collapsibility During REM Sleep in Children with the Obstructive Sleep Apnea Syndrome

    PubMed Central

    Huang, Jingtao; Karamessinis, Laurie R.; Pepe, Michelle E.; Glinka, Stephen M.; Samuel, John M.; Gallagher, Paul R.; Marcus, Carole L.

    2009-01-01

    Study Objectives: In children, most obstructive events occur during rapid eye movement (REM) sleep. We hypothesized that children with the obstructive sleep apnea syndrome (OSAS), in contrast to age-matched control subjects, would not maintain airflow in the face of an upper airway inspiratory pressure drop during REM sleep. Design: During slow wave sleep (SWS) and REM sleep, we measured airflow, inspiratory time, inspiratory time/total respiratory cycle time, respiratory rate, tidal volume, and minute ventilation at a holding pressure at which flow limitation occurred and at 5 cm H2O below the holding pressure in children with OSAS and in control subjects. Setting: Sleep laboratory. Participants: Fourteen children with OSAS and 23 normal control subjects. Results: In both sleep states, control subjects were able to maintain airflow, whereas subjects with OSAS preserved airflow in SWS but had a significant decrease in airflow during REM sleep (change in airflow of 18.58 ± 12.41 mL/s for control subjects vs −44.33 ± 14.09 mL/s for children with OSAS, P = 0.002). Although tidal volume decreased, patients with OSAS were able to maintain minute ventilation by increasing the respiratory rate and also had an increase in inspiratory time and inspiratory time per total respiratory cycle time Conclusion: Children with OSAS do not maintain airflow in the face of upper-airway inspiratory-pressure drops during REM sleep, indicating a more collapsible upper airway, compared with that of control subjects during REM sleep. However, compensatory mechanisms exist to maintain minute ventilation. Local reflexes, central control mechanisms, or both reflexes and control mechanisms need to be further explored to better understand the pathophysiology of this abnormality and the compensation mechanism. Citation: Huang J; Karamessinis LR; Pepe ME; Glinka SM; Samuel JM; Gallagher PR; Marcus CL. Upper airway collapsibility during REM sleep in children with the obstructive sleep apnea

  10. Impulse oscillometry: a measure for airway obstruction.

    PubMed

    Vink, Geraldine R; Arets, Hubertus G M; van der Laag, Johan; van der Ent, Cornelis K

    2003-03-01

    The impulse oscillometry system (IOS) was introduced as a new technique to assess airflow obstruction in patients who are not able to perform forced breathing maneuvers, e.g., subjects with cerebral palsy or severe mental retardation, and young children. This study evaluates the sensitivity and specificity of IOS parameters to quantify changes in airflow obstruction in comparison with forced expiratory volume in the first second (FEV(1)) and peak expiratory flow (PEF) measurements. Measurements of FEV(1), PEF, and resistance (R) and reactance (X) at frequencies of 5-35 Hz were performed in 19 children with asthma before, during, and after methacholine challenge and subsequent bronchodilatation. All parameters changed significantly during tests. Values of R5 and R10 correlated with FEV(1) (r = -0.71 and -0.73, respectively, P < 0.001), as did values of X5 and X10 (r = 0.52 and 0.57, respectively, P < 0.01). Changes in R preceded changes in PEF and FEV(1) during methacholine challenge. The area under the receiver operating characteristic (ROC) curve to predict a 15% fall in FEV(1) showed better sensitivity and specificity for R5 (area under the curve, 0.85) compared to PEF (0.79) or R10 (0.73). We conclude that IOS parameters can be easily used as an indirect measure of airflow obstruction. This might be helpful in patients who are not able to perform forced breathing maneuvers. In individual subjects, R values measured at 5 Hz showed to be superior to PEF measurements in the detection of a 15% fall in FEV(1). Copyright 2003 Wiley-Liss, Inc.

  11. Assessing Airflow Sensitivity to Healthy and Diseased Lung Conditions in a Computational Fluid Dynamics Model Validated In Vitro.

    PubMed

    Sul, Bora; Oppito, Zachary; Jayasekera, Shehan; Vanger, Brian; Zeller, Amy; Morris, Michael; Ruppert, Kai; Altes, Talissa; Rakesh, Vineet; Day, Steven; Robinson, Risa; Reifman, Jaques; Wallqvist, Anders

    2018-05-01

    Computational models are useful for understanding respiratory physiology. Crucial to such models are the boundary conditions specifying the flow conditions at truncated airway branches (terminal flow rates). However, most studies make assumptions about these values, which are difficult to obtain in vivo. We developed a computational fluid dynamics (CFD) model of airflows for steady expiration to investigate how terminal flows affect airflow patterns in respiratory airways. First, we measured in vitro airflow patterns in a physical airway model, using particle image velocimetry (PIV). The measured and computed airflow patterns agreed well, validating our CFD model. Next, we used the lobar flow fractions from a healthy or chronic obstructive pulmonary disease (COPD) subject as constraints to derive different terminal flow rates (i.e., three healthy and one COPD) and computed the corresponding airflow patterns in the same geometry. To assess airflow sensitivity to the boundary conditions, we used the correlation coefficient of the shape similarity (R) and the root-mean-square of the velocity magnitude difference (Drms) between two velocity contours. Airflow patterns in the central airways were similar across healthy conditions (minimum R, 0.80) despite variations in terminal flow rates but markedly different for COPD (minimum R, 0.26; maximum Drms, ten times that of healthy cases). In contrast, those in the upper airway were similar for all cases. Our findings quantify how variability in terminal and lobar flows contributes to airflow patterns in respiratory airways. They highlight the importance of using lobar flow fractions to examine physiologically relevant airflow characteristics.

  12. Chronic obstructive pulmonary disease mortality and prevalence: the associations with smoking and poverty--a BOLD analysis.

    PubMed

    Burney, Peter; Jithoo, Anamika; Kato, Bernet; Janson, Christer; Mannino, David; Nizankowska-Mogilnicka, Ewa; Studnicka, Michael; Tan, Wan; Bateman, Eric; Koçabas, Ali; Vollmer, William M; Gislason, Thorarrin; Marks, Guy; Koul, Parvaiz A; Harrabi, Imed; Gnatiuc, Louisa; Buist, Sonia

    2014-05-01

    Chronic obstructive pulmonary disease (COPD) is a commonly reported cause of death and associated with smoking. However, COPD mortality is high in poor countries with low smoking rates. Spirometric restriction predicts mortality better than airflow obstruction, suggesting that the prevalence of restriction could explain mortality rates attributed to COPD. We have studied associations between mortality from COPD and low lung function, and between both lung function and death rates and cigarette consumption and gross national income per capita (GNI). National COPD mortality rates were regressed against the prevalence of airflow obstruction and spirometric restriction in 22 Burden of Obstructive Lung Disease (BOLD) study sites and against GNI, and national smoking prevalence. The prevalence of airflow obstruction and spirometric restriction in the BOLD sites were regressed against GNI and mean pack years smoked. National COPD mortality rates were more strongly associated with spirometric restriction in the BOLD sites (<60 years: men rs=0.73, p=0.0001; women rs=0.90, p<0.0001; 60+ years: men rs=0.63, p=0.0022; women rs=0.37, p=0.1) than obstruction (<60 years: men rs=0.28, p=0.20; women rs=0.17, p<0.46; 60+ years: men rs=0.28, p=0.23; women rs=0.22, p=0.33). Obstruction increased with mean pack years smoked, but COPD mortality fell with increased cigarette consumption and rose rapidly as GNI fell below US$15 000. Prevalence of restriction was not associated with smoking but also increased rapidly as GNI fell below US$15 000. Smoking remains the single most important cause of obstruction but a high prevalence of restriction associated with poverty could explain the high 'COPD' mortality in poor countries.

  13. Changes in prevalence of chronic obstructive pulmonary disease and asthma in the US population and associated risk factors

    PubMed Central

    Halldin, Cara N; Doney, Brent C; Hnizdo, Eva

    2017-01-01

    Chronic lower airway diseases, including chronic obstructive pulmonary disease (COPD) and asthma, are currently the third leading cause of death in the United States. We aimed to evaluate changes in prevalence of and risk factors for COPD and asthma among the US adult population. We evaluated changes in prevalence of self-reported doctor-diagnosed COPD (i.e. chronic bronchitis and emphysema) and asthma and self-reported respiratory symptoms comparing data from the 1988–1994 and 2007–2010 National Health and Nutrition Examination Surveys. To investigate changes in the severity of each outcome over the two periods, we calculated changes in the proportions of spirometry-based airflow obstruction for each outcome. Prevalence of doctor-diagnosed chronic bronchitis and emphysema decreased significantly mainly among males, while asthma increased only among females. The self-reported disease and the respiratory symptoms were associated with increased prevalence of airflow obstruction for both periods. However, the prevalence of airflow obstruction decreased significantly in the second period among those with shortness of breath and doctor-diagnosed respiratory conditions (chronic bronchitis, emphysema, and asthma). COPD outcomes and asthma were associated with lower education, smoking, underweight and obesity, and occupational dusts and fumes exposure. Chronic lower airway diseases continue to be major public health problems. However, decreased prevalence of doctor-diagnosed chronic bronchitis and emphysema (in males) and decreased prevalence of airflow obstruction in those with respiratory symptoms and doctor-diagnosed respiratory diseases may indicate a declining trend and decrease in disease severity between the two periods. Continued focus on prevention of these diseases through public health interventions is prudent. PMID:25540134

  14. Minimum airflow reset of single-duct VAV terminal boxes

    NASA Astrophysics Data System (ADS)

    Cho, Young-Hum

    Single duct Variable Air Volume (VAV) systems are currently the most widely used type of HVAC system in the United States. When installing such a system, it is critical to determine the minimum airflow set point of the terminal box, as an optimally selected set point will improve the level of thermal comfort and indoor air quality (IAQ) while at the same time lower overall energy costs. In principle, this minimum rate should be calculated according to the minimum ventilation requirement based on ASHRAE standard 62.1 and maximum heating load of the zone. Several factors must be carefully considered when calculating this minimum rate. Terminal boxes with conventional control sequences may result in occupant discomfort and energy waste. If the minimum rate of airflow is set too high, the AHUs will consume excess fan power, and the terminal boxes may cause significant simultaneous room heating and cooling. At the same time, a rate that is too low will result in poor air circulation and indoor air quality in the air-conditioned space. Currently, many scholars are investigating how to change the algorithm of the advanced VAV terminal box controller without retrofitting. Some of these controllers have been found to effectively improve thermal comfort, indoor air quality, and energy efficiency. However, minimum airflow set points have not yet been identified, nor has controller performance been verified in confirmed studies. In this study, control algorithms were developed that automatically identify and reset terminal box minimum airflow set points, thereby improving indoor air quality and thermal comfort levels, and reducing the overall rate of energy consumption. A theoretical analysis of the optimal minimum airflow and discharge air temperature was performed to identify the potential energy benefits of resetting the terminal box minimum airflow set points. Applicable control algorithms for calculating the ideal values for the minimum airflow reset were developed and

  15. Prevalence of asthma with airflow limitation, COPD, and COPD with variable airflow limitation in older subjects in a general Japanese population: the Hisayama Study.

    PubMed

    Matsumoto, Koichiro; Seki, Nanae; Fukuyama, Satoru; Moriwaki, Atsushi; Kan-o, Keiko; Matsunaga, Yuko; Noda, Naotaka; Yoshida, Makoto; Koto, Hiroshi; Takata, Shohei; Nakanishi, Yoichi; Kiyohara, Yutaka; Inoue, Hiromasa

    2015-01-01

    Elucidating the prevalence of asthma and chronic obstructive pulmonary disease (COPD) is important for designing a public health strategy. Recent studies have discriminated a phenotype of COPD with variable airflow limitation (COPD-VAL) associated with asthma-COPD overlap syndrome. Its prevalence remains uncertain. The age and occupational distributions in the town of Hisayama and in Japan are nearly identical. Each disease's prevalence was estimated for the town's residents. In 2008, town residents (≥ 40 years) were solicited to participate in a health checkup. Individuals with abnormal spirometry (forced expiratory volume in 1s/forced vital capacity [FEV1/FVC]<70% and/or %FVC<80%) were recommended for further evaluations. Two pulmonologists in a blinded fashion reviewed their medical records, including bronchodilator reversibility. Individuals with airflow limitation were classified as having asthma, COPD, COPD-VAL, or other diseases. The prevalence of each disease was then estimated. A total of 2100 residents (43.4% of residents in the age group) completed spirometry. In 455 residents with abnormal spirometry, 190 residents had further evaluations, and the medical records of 174 residents were reviewed. The prevalence of asthma with airflow limitation, COPD, and COPD-VAL, were 2.0%, 8.4%, and 0.9%, respectively. The prevalence of COPD and COPD-VAL were higher in men and smokers than in women and never-smokers. The prevalence of COPD, but not COPD-VAL or asthma, increased with age. The prevalence of asthma with airflow limitation, COPD, and COPD-VAL were estimated in a population of residents (≥ 40 years) in Hisayama. Copyright © 2014 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.

  16. Numerical analysis for the efficacy of nasal surgery in obstructive sleep apnea hypopnea syndrome

    NASA Astrophysics Data System (ADS)

    Yu, Shen; Liu, Ying-Xi; Sun, Xiu-Zhen; Su, Ying-Feng; Wang, Ying; Gai, Yin-Zhe

    2014-04-01

    In the present study, we reconstructed upper airway and soft palate models of 3 obstructive sleep apnea—hypopnea syndrome (OSAHS) patients with nasal obstruction. The airflow distribution and movement of the soft palate before and after surgery were described by a numerical simulation method. The curative effect of nasal surgery was evaluated for the three patients with OSAHS. The degree of nasal obstruction in the 3 patients was improved after surgery. For 2 patients with mild OSAHS, the upper airway resistance and soft palate displacement were reduced after surgery. These changes contributed to the mitigation of respiratory airflow limitation. For the patient with severe OSAHS, the upper airway resistance and soft palate displacement increased after surgery, which aggravated the airway obstruction. The efficacy of nasal surgery for patients with OSAHS is determined by the degree of improvement in nasal obstruction and whether the effects on the pharynx are beneficial. Numerical simulation results are consistent with the polysomnogram (PSG) test results, chief complaints, and clinical findings, and can indirectly reflect the degree of nasal patency and improvement of snoring symptoms, and further, provide a theoretical basis to solve relevant clinical problems. [Figure not available: see fulltext.

  17. Office-based spirometry for early detection of obstructive lung disease.

    PubMed

    Wallace, Laura D; Troy, Kenneth E

    2006-09-01

    To review the research-based evidence supporting smoking cessation as the only proven method to reduce chronic obstructive pulmonary disease (COPD) progression and to show that early detection of disease with office-based spirometry can lead to therapeutic intervention before physiologic symptoms arise. Extensive review of national and international scientific literature supplemented with drawings and algorithms. Early detection of COPD with spirometry, along with smoking cessation, and aggressive intervention can alter the insidious course of this highly preventable disease. It is imperative that nurse practitioners utilize this simple and inexpensive procedure to identify COPD in its earliest stages, so treatment can reduce individual and community disease burden, reduce morbidity and mortality, and help reduce healthcare costs. Determination of early airflow obstruction supports smoking cessation education, provides objective data for patient motivation, thereby doubling patient compliance and reducing further disease burden.

  18. Effects of pharmacologic treatment based on airflow limitation and breathlessness on daily physical activity in patients with chronic obstructive pulmonary disease.

    PubMed

    Minakata, Yoshiaki; Morishita, Yukiko; Ichikawa, Tomohiro; Akamatsu, Keiichiro; Hirano, Tsunahiko; Nakanishi, Masanori; Matsunaga, Kazuto; Ichinose, Masakazu

    2015-01-01

    Improvement in the daily physical activity (PA) is important for the management of chronic obstructive pulmonary disease (COPD). However, the effects of pharmacologic treatment on PA are not well understood. We evaluated the effects of additional medications, including bronchodilator with or without inhaled corticosteroid, based on airflow limitation and breathlessness on the PA in COPD patients and the factors that could predict or affect the improvement in PA. A prospective non-randomized observational study was employed. Twenty-one COPD subjects without any other diseases that might reduce PA were recruited. The PA was measured with a triaxial accelerometer for 2 weeks, and pulmonary function tests and incremental shuttle walking tests were administered before and after 4-week treatment with an additional medication. Bronchodilation was obtained by additional medication. The mean values of PA evaluated by metabolic equivalents (METs) at ≥3.0 METs and the duration of PA at ≥3.0 METs and ≥3.5 METs were improved by medication. The % change in the duration of PA at ≥3.5 METs was significantly correlated with the baseline functional residual capacity (FRC), residual volume, and inspiratory capacity/total lung capacity. However, the % change in the duration of PA at any intensity was not correlated with the % changes of any values of the pulmonary function tests or incremental shuttle walking test except the PA at ≥2.5 METs with FRC. Medication could improve the PA in patients with COPD, especially at a relatively high intensity of activity when medication was administered based on airflow limitation and breathlessness. The improvement was seen in the patients with better baseline lung volume, but was not correlated with the improvements in the pulmonary function tests or exercise capacity.

  19. Mild Airflow Limitation during N2 Sleep Increases K-complex Frequency and Slows Electroencephalographic Activity.

    PubMed

    Nguyen, Chinh D; Wellman, Andrew; Jordan, Amy S; Eckert, Danny J

    2016-03-01

    To determine the effects of mild airflow limitation on K-complex frequency and morphology and electroencephalogram (EEG) spectral power. Transient reductions in continuous positive airway pressure (CPAP) during stable N2 sleep were performed to induce mild airflow limitation in 20 patients with obstructive sleep apnea (OSA) and 10 healthy controls aged 44 ± 13 y. EEG at C3 and airflow were measured in 1-min windows to quantify K-complex properties and EEG spectral power immediately before and during transient reductions in CPAP. The frequency and morphology (amplitude and latency of P200, N550 and N900 components) of K-complexes and EEG spectral power were compared between conditions. During mild airflow limitation (18% reduction in peak inspiratory airflow from baseline, 0.38 ± 0.11 versus 0.31 ± 0.1 L/sec) insufficient to cause American Academy of Sleep Medicine-defined cortical arousal, K-complex frequency (9.5 ± 4.5 versus 13.7 ± 6.4 per min, P < 0.01), N550 amplitude (25 ± 3 versus 27 ± 3 μV, P < 0.01) and EEG spectral power (delta: 147 ± 48 versus 230 ± 99 μV(2), P < 0.01 and theta bands: 31 ± 14 versus 34 ± 13 μV(2), P < 0.01) significantly increased whereas beta band power decreased (14 ± 5 versus 11 ± 4 μV(2), P < 0.01) compared to the preceding non flow-limited period on CPAP. K-complex frequency, morphology, and timing did not differ between patients and controls. Mild airflow limitation increases K-complex frequency, N550 amplitude, and spectral power of delta and theta bands. In addition to providing mechanistic insight into the role of mild airflow limitation on K-complex characteristics and EEG activity, these findings may have important implications for respiratory conditions in which airflow limitation during sleep is common (e.g., snoring and OSA). © 2016 Associated Professional Sleep Societies, LLC.

  20. α1-Antitrypsin Protease Inhibitor MZ Heterozygosity Is Associated With Airflow Obstruction in Two Large Cohorts

    PubMed Central

    Sørheim, Inga-Cecilie; Bakke, Per; Gulsvik, Amund; Pillai, Sreekumar G.; Johannessen, Ane; Gaarder, Per I.; Campbell, Edward J.; Agustí, Alvar; Calverley, Peter M. A.; Donner, Claudio F.; Make, Barry J.; Rennard, Stephen I.; Vestbo, Jørgen; Wouters, Emiel F. M.; Paré, Peter D.; Levy, Robert D.; Coxson, Harvey O.; Lomas, David A.; Hersh, Craig P.

    2010-01-01

    Background: Severe α1-antitrypsin deficiency is a known genetic risk factor for COPD. Heterozygous (protease inhibitor [PI] MZ) individuals have moderately reduced serum levels of α1-antitrypsin, but whether they have an increased risk of COPD is uncertain. Methods: We compared PI MZ and PI MM individuals in two large populations: a case-control study from Norway (n = 1,669) and a multicenter family-based study from Europe and North America (n = 2,707). We sought to determine whether PI MZ was associated with the specific COPD-related phenotypes of lung function and quantitative CT scan measurements of emphysema and airway disease. Results: PI MZ was associated with a 3.5% lower FEV1/FVC ratio in the case-control study (P = .035) and 3.9% lower FEV1/vital capacity (VC) ratio in the family study (P = .009). In the case-control study, PI MZ also was associated with 3.7% more emphysema on quantitative analysis of chest CT scans (P = .003). The emphysema result was not replicated in the family study. PI MZ was not associated with airway wall thickness or COPD status in either population. Among subjects with low smoking exposure (< 20 pack-years), PI MZ individuals had more severe emphysema on chest CT scan than PI MM individuals in both studies. Conclusions: Compared with PI MM individuals, PI MZ heterozygotes had lower FEV1/(F)VC ratio in two independent studies. Our results suggest that PI MZ individuals may be slightly more susceptible to the development of airflow obstruction than PI MM individuals. PMID:20595457

  1. [Hungarian Society for Sleep Medicine guideline for detecting drivers with obstructive sleep apnea syndrome].

    PubMed

    Szakács, Zoltán; Ádám, Ágnes; Annus, János Kristóf; Csatlós, Dalma; László, Andrea; Kalabay, László; Torzsa, Péter

    2016-06-05

    Obstructive sleep apnea is the most frequent sleep-disordered breathing. The prevalence of sleep apnea in the general population is 2-4% and the main characteristics of the disease are the intermittent cessation or substantial reduction of airflow during sleep, which is caused by complete, or near complete upper airway obstruction. Decreased airflow is followed by oxygen desaturation and intermittent arousals. Untreated patients are 4-6 times more likely to cause traffic accidents than their healthy counterparts. The aims of the obstructive sleep apnea screening are to prevent and reduce the incidence of serious car accidents, which are often caused by one of the most dangerous sleep disorders. Since April 1, 2015 a modification of the 13/1992 regulation has been in force in Hungary which orders screening of obstructive sleep apnea during medical checkup of drivers. The Hungarian Society for Sleep Medicine made a guideline according to the regulation which was adapted to national circumstances and family doctors, occupational health specialists can more easily screen obstructive sleep apnea in suspected patients. In sleep ambulances the disease can be diagnosed and effective treatment can be started. Patients receiving appropriate treatment and with appropriate compliance can get their driving licence under regular care and control.

  2. Mild Airflow Limitation during N2 Sleep Increases K-complex Frequency and Slows Electroencephalographic Activity

    PubMed Central

    Nguyen, Chinh D.; Wellman, Andrew; Jordan, Amy S.; Eckert, Danny J.

    2016-01-01

    Study Objectives: To determine the effects of mild airflow limitation on K-complex frequency and morphology and electroencephalogram (EEG) spectral power. Methods: Transient reductions in continuous positive airway pressure (CPAP) during stable N2 sleep were performed to induce mild airflow limitation in 20 patients with obstructive sleep apnea (OSA) and 10 healthy controls aged 44 ± 13 y. EEG at C3 and airflow were measured in 1-min windows to quantify K-complex properties and EEG spectral power immediately before and during transient reductions in CPAP. The frequency and morphology (amplitude and latency of P200, N550 and N900 components) of K-complexes and EEG spectral power were compared between conditions. Results: During mild airflow limitation (18% reduction in peak inspiratory airflow from baseline, 0.38 ± 0.11 versus 0.31 ± 0.1 L/sec) insufficient to cause American Academy of Sleep Medicine-defined cortical arousal, K-complex frequency (9.5 ± 4.5 versus 13.7 ± 6.4 per min, P < 0.01), N550 amplitude (25 ± 3 versus 27 ± 3 μV, P < 0.01) and EEG spectral power (delta: 147 ± 48 versus 230 ± 99 μV2, P < 0.01 and theta bands: 31 ± 14 versus 34 ± 13 μV2, P < 0.01) significantly increased whereas beta band power decreased (14 ± 5 versus 11 ± 4 μV2, P < 0.01) compared to the preceding non flow-limited period on CPAP. K-complex frequency, morphology, and timing did not differ between patients and controls. Conclusion: Mild airflow limitation increases K-complex frequency, N550 amplitude, and spectral power of delta and theta bands. In addition to providing mechanistic insight into the role of mild airflow limitation on K-complex characteristics and EEG activity, these findings may have important implications for respiratory conditions in which airflow limitation during sleep is common (e.g., snoring and OSA). Citation: Nguyen CD, Wellman A, Jordan AS, Eckert DJ. Mild airflow limitation during N2 sleep increases k-complex frequency and slows

  3. Clinical Characterization and Treatment Patterns for the Frequent Exacerbator Phenotype in Chronic Obstructive Pulmonary Disease with Severe or Very Severe Airflow Limitation.

    PubMed

    Blasi, Francesco; Neri, Luca; Centanni, Stefano; Falcone, Franco; Di Maria, Giuseppe

    2017-02-01

    Chronic obstructive pulmonary disease (COPD) patients experiencing several episodes of acute clinical derangement suffer from increased morbidity, mortality, and accelerated decline in lung function. Nevertheless, the relationship between co-morbidity profile and exacerbation rates in the frequent exacerbator phenotype is poorly characterized, and evidence-based management guidelines are lacking. We sought to evaluate the co-morbidity profile and treatment patterns of "frequent exacerbators" with severe or very severe airflow limitation. We conducted a cross-sectional, multicenter study in 50 Italian hospitals. Pulmonologists abstracted clinical information from medical charts of 743 COPD frequent exacerbators. We evaluated the exacerbation risk and center-related variations in diagnostic testing. One-third of patients (n = 210) underwent a bronchodilator response test, and 163 (22%) received a computerized tomography (CT) scan; 35 had a partial response to bronchodilators, while 119 had a diagnosis of emphysema; 584 (79%) lacked sufficient diagnostic testing for classification. Only 17% of patients did not have any coexistent disease. Cardiovascular conditions were the most frequent co-morbidities. A history of heart failure [odds ratio (OR): 1.89; 95% confidence interval (CI) 1.48-2.3] and affective disorders (OR: 1.66; 95% CI 1.24-2.1) was associated with the frequency of exacerbations. Center membership was strongly associated with exacerbation risk, independent of casemix (variance partition coefficient = 29.6%). Examining the regional variation in health outcomes and health care behavior may help identify the best practices, especially when evidence-based recommendations are lacking and uncertainties surround clinical decision-making.

  4. Chronic Obstructive Pulmonary Disease and Health-Related Quality of Life in the 2009 Texas Behavioral Risk Factor Survey

    ERIC Educational Resources Information Center

    Jackson, Bradford E.; Suzuki, Sumihiro; Coultas, David; Singh, Karan P.; Bae, Sejong

    2013-01-01

    Introduction: Individuals with chronic obstructive pulmonary disease (COPD) experience irreversible airflow obstruction, dyspnea, coughing, and fatigue. One of the goals of treating individuals with COPD is to improve their quality of life. The aim of this research was to evaluate the 2009 Texas Behavioral Risk Factor Surveillance System (BRFSS)…

  5. Chronic air-flow limitation does not increase respiratory epithelial permeability assessed by aerosolized solute, but smoking does

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huchon, G.J.; Russell, J.A.; Barritault, L.G.

    1984-09-01

    To determine the separate influences of smoking and severe air-flow limitation on aerosol deposition and respiratory epithelial permeability, we studied 26 normal nonsmokers, 12 smokers without airway obstruction, 12 nonsmokers with chronic obstructive pulmonary disease (COPD), and 11 smokers with COPD. We aerosolized 99mTc-labeled diethylene triamine pentaacetic acid to particles approximately 1 micron activity median aerodynamic diameter. Levels of radioactivity were plotted semilogarithmically against time to calculate clearance as percent per minute. The distribution of radioactivity was homogeneous in control subjects and in smokers, but patchy in both groups with COPD. No difference was found between clearances of the controlmore » group (1.18 +/- 0.31% min-1), and nonsmoker COPD group (1.37 +/- 0.82% min-1), whereas values in smokers without COPD (4.00 +/- 1.70% min-1) and smokers with COPD (3.62 +/- 2.88% min-1) were significantly greater than in both nonsmoking groups. We conclude that (1) small particles appear to deposit peripherally, even with severe COPD; (2) respiratory epithelial permeability is normal in nonsmokers with COPD; (3) smoking increases permeability by a mechanism unrelated to air-flow limitation.« less

  6. Fluid structure interaction simulations of the upper airway in obstructive sleep apnea patients before and after maxillomandibular advancement surgery.

    PubMed

    Chang, Kwang K; Kim, Ki Beom; McQuilling, Mark W; Movahed, Reza

    2018-06-01

    The purpose of this study was to analyze pharyngeal airflow using both computational fluid dynamics (CFD) and fluid structure interactions (FSI) in obstructive sleep apnea patients before and after maxillomandibular advancement (MMA) surgery. The airflow characteristics before and after surgery were compared with both CFD and FSI. In addition, the presurgery and postsurgery deformations of the airway were evaluated using FSI. Digitized pharyngeal airway models of 2 obstructive sleep apnea patients were generated from cone-beam computed tomography scans before and after MMA surgery. CFD and FSI were used to evaluate the pharyngeal airflow at a maximum inspiration rate of 166 ml per second. Standard steady-state numeric formulations were used for airflow simulations. Airway volume increased, pressure drop decreased, maximum airflow velocity decreased, and airway resistance dropped for both patients after the MMA surgery. These findings occurred in both the CFD and FSI simulations. The FSI simulations showed an area of marked airway deformation in both patients before surgery, but this deformation was negligible after surgery for both patients. Both CFD and FSI simulations produced airflow results that indicated less effort was needed to breathe after MMA surgery. The FSI simulations demonstrated a substantial decrease in airway deformation after surgery. These beneficial changes positively correlated with the large improvements in polysomnography outcomes after MMA surgery. Copyright © 2018 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  7. Numerical simulation of soft palate movement and airflow in human upper airway by fluid-structure interaction method

    NASA Astrophysics Data System (ADS)

    Sun, Xiuzhen; Yu, Chi; Wang, Yuefang; Liu, Yingxi

    2007-08-01

    In this paper, the authors present airflow field characteristics of human upper airway and soft palate movement attitude during breathing. On the basis of the data taken from the spiral computerized tomography images of a healthy person and a patient with Obstructive Sleep Apnea-Hypopnea Syndrome (OSAHS), three-dimensional models of upper airway cavity and soft palate are reconstructed by the method of surface rendering. Numerical simulation is performed for airflow in the upper airway and displacement of soft palate by fluid-structure interaction analysis. The reconstructed three-dimensional models precisely preserve the original configuration of upper airways and soft palate. The results of the pressure and velocity distributions in the airflow field are quantitatively determined, and the displacement of soft palate is presented. Pressure gradients of airway are lower for the healthy person and the airflow distribution is quite uniform in the case of free breathing. However, the OSAHS patient remarkably escalates both the pressure and velocity in the upper airway, and causes higher displacement of the soft palate. The present study is useful in revealing pathogenesis and quantitative mutual relationship between configuration and function of the upper airway as well as in diagnosing diseases related to anatomical structure and function of the upper airway.

  8. A systems biology approach identifies molecular networks defining skeletal muscle abnormalities in chronic obstructive pulmonary disease.

    PubMed

    Turan, Nil; Kalko, Susana; Stincone, Anna; Clarke, Kim; Sabah, Ayesha; Howlett, Katherine; Curnow, S John; Rodriguez, Diego A; Cascante, Marta; O'Neill, Laura; Egginton, Stuart; Roca, Josep; Falciani, Francesco

    2011-09-01

    Chronic Obstructive Pulmonary Disease (COPD) is an inflammatory process of the lung inducing persistent airflow limitation. Extensive systemic effects, such as skeletal muscle dysfunction, often characterize these patients and severely limit life expectancy. Despite considerable research efforts, the molecular basis of muscle degeneration in COPD is still a matter of intense debate. In this study, we have applied a network biology approach to model the relationship between muscle molecular and physiological response to training and systemic inflammatory mediators. Our model shows that failure to co-ordinately activate expression of several tissue remodelling and bioenergetics pathways is a specific landmark of COPD diseased muscles. Our findings also suggest that this phenomenon may be linked to an abnormal expression of a number of histone modifiers, which we discovered correlate with oxygen utilization. These observations raised the interesting possibility that cell hypoxia may be a key factor driving skeletal muscle degeneration in COPD patients.

  9. Power requirement of rotating rods in airflow

    NASA Technical Reports Server (NTRS)

    Barna, P. S.; Crossman, G. R.

    1974-01-01

    Experiments were performed to determine the power required for rotating a rotor disc fitted with a number of radially arranged rods placed into a ducted airflow. An array of stationary rods, also radially arranged, were placed upstream close to the rotor with a small gap between the rods to cause wake interference. The results show that power increased with increasing airflow and the rate of increase varied considerably. At lower values of airflow the rate of increase was larger than at higher airflow and definite power peaks occurred at certain airflow rates, where the power attained a maximum within the test airflow range. During the test a maximum blade passage frequency of 2037 Hz was attained.

  10. Obstructive sleep apnea among commercial motor vehicle drivers: using evidence-based practice to identify risk factors.

    PubMed

    Olszewski, Kimberly; Wolf, Debra

    2013-11-01

    Commercial motor vehicle driving is a hazardous occupation, having the third highest fatality rate among common U.S. jobs. Among the estimated 14 million U.S. commercial motor vehicle drivers, the prevalence of obstructive sleep apnea is reported to be 17% to 28%. Despite the identified increased prevalence of obstructive sleep apnea among commercial motor vehicle drivers, federal law does not require that they be screened for obstructive sleep apnea. This article presents an evidence-based practice change project; the authors developed, implemented, and evaluated a screening program to identify commercial motor vehicle drivers' risk for obstructive sleep apnea during commercial driver medical examinations. The results of this practice change indicated screening for obstructive sleep apnea during the commercial driver medical examination led to improved identification of obstructive sleep apnea risk among commercial motor vehicle drivers and should be a clinical standard in occupational health clinics. Copyright 2013, SLACK Incorporated.

  11. Underground anemotactic orientation in leaf-cutting ants: perception of airflow and experience-dependent choice of airflow direction during digging

    NASA Astrophysics Data System (ADS)

    Halboth, Florian; Roces, Flavio

    2017-10-01

    Air exchange between the large nests of Atta vollenweideri leaf-cutting ants and the environment strongly relies on a passive, wind-induced ventilation mechanism. Air moves through nest tunnels and airflow direction depends on the location of the tunnel openings on the nest mound. We hypothesized that ants might use the direction of airflow along nest tunnels as orientation cue in the context of climate control, as digging workers might prefer to broaden or to close tunnels with inflowing or outflowing air in order to regulate nest ventilation. To investigate anemotactic orientation in Atta vollenweideri, we first tested the ants' ability to perceive air movements by confronting single workers with airflow stimuli in the range 0 to 20 cm/s. Workers responded to airflow velocities ≥ 2 cm/s, and the number of ants reacting to the stimulus increased with increasing airflow speed. Second, we asked whether digging workers use airflow direction as an orientation cue. Workers were exposed to either inflow or outflow of air while digging in the nest and could subsequently choose between two digging sites providing either inflow or outflow of air, respectively. Workers significantly chose the side with the same airflow direction they experienced before. When no airflow was present during initial digging, workers showed no preference for airflow directions. Workers developed preferences for airflow direction only after previous exposure to a given airflow direction. We suggest that experience-modified anemotaxis might help leaf-cutting ants spatially organize their digging activity inside the nest during tasks related to climate control.

  12. Underground anemotactic orientation in leaf-cutting ants: perception of airflow and experience-dependent choice of airflow direction during digging.

    PubMed

    Halboth, Florian; Roces, Flavio

    2017-09-19

    Air exchange between the large nests of Atta vollenweideri leaf-cutting ants and the environment strongly relies on a passive, wind-induced ventilation mechanism. Air moves through nest tunnels and airflow direction depends on the location of the tunnel openings on the nest mound. We hypothesized that ants might use the direction of airflow along nest tunnels as orientation cue in the context of climate control, as digging workers might prefer to broaden or to close tunnels with inflowing or outflowing air in order to regulate nest ventilation. To investigate anemotactic orientation in Atta vollenweideri, we first tested the ants' ability to perceive air movements by confronting single workers with airflow stimuli in the range 0 to 20 cm/s. Workers responded to airflow velocities ≥ 2 cm/s, and the number of ants reacting to the stimulus increased with increasing airflow speed. Second, we asked whether digging workers use airflow direction as an orientation cue. Workers were exposed to either inflow or outflow of air while digging in the nest and could subsequently choose between two digging sites providing either inflow or outflow of air, respectively. Workers significantly chose the side with the same airflow direction they experienced before. When no airflow was present during initial digging, workers showed no preference for airflow directions. Workers developed preferences for airflow direction only after previous exposure to a given airflow direction. We suggest that experience-modified anemotaxis might help leaf-cutting ants spatially organize their digging activity inside the nest during tasks related to climate control.

  13. A Systems Biology Approach Identifies Molecular Networks Defining Skeletal Muscle Abnormalities in Chronic Obstructive Pulmonary Disease

    PubMed Central

    Turan, Nil; Kalko, Susana; Stincone, Anna; Clarke, Kim; Sabah, Ayesha; Howlett, Katherine; Curnow, S. John; Rodriguez, Diego A.; Cascante, Marta; O'Neill, Laura; Egginton, Stuart; Roca, Josep; Falciani, Francesco

    2011-01-01

    Chronic Obstructive Pulmonary Disease (COPD) is an inflammatory process of the lung inducing persistent airflow limitation. Extensive systemic effects, such as skeletal muscle dysfunction, often characterize these patients and severely limit life expectancy. Despite considerable research efforts, the molecular basis of muscle degeneration in COPD is still a matter of intense debate. In this study, we have applied a network biology approach to model the relationship between muscle molecular and physiological response to training and systemic inflammatory mediators. Our model shows that failure to co-ordinately activate expression of several tissue remodelling and bioenergetics pathways is a specific landmark of COPD diseased muscles. Our findings also suggest that this phenomenon may be linked to an abnormal expression of a number of histone modifiers, which we discovered correlate with oxygen utilization. These observations raised the interesting possibility that cell hypoxia may be a key factor driving skeletal muscle degeneration in COPD patients. PMID:21909251

  14. Perception of Better Nasal Patency Correlates with Increased Mucosal Cooling after Surgery for Nasal Obstruction

    NASA Astrophysics Data System (ADS)

    Garcia, Guilherme; Sullivan, Corbin; Frank-Ito, Dennis; Kimbell, Julia; Rhee, John

    2014-11-01

    Nasal airway obstruction (NAO) is a common health problem with 340,000 patients undergoing surgery annually in the United States. Traditionally, otolaryngologists have focused on airspace cross-sectional areas and nasal resistance to airflow as objective measures of nasal patency, but neither of these variables correlated consistently with patients' symptoms. Given that the sensation of nasal airflow is also associated with mucosal cooling (i.e., heat loss) during inspiration, we investigated the correlation between the sensation of nasal obstruction and mucosal cooling in 10 patients before and after NAO surgery. Three-dimensional models of the nasal anatomy were created based on pre- and post-surgery computed tomography scans. Computational fluid dynamics (CFD) simulations were conducted to quantify nasal resistance and mucosal cooling. Patient-reported symptoms were measured by a visual analog scale and the Nasal Obstruction Symptom Evaluation (NOSE), a disease-specific quality of life questionnaire. Our results revealed that the subjective sensation of nasal obstruction correlated with both nasal resistance and heat loss, but the strongest correlation was between the NOSE score and the nasal surface area where heat flux exceeds 50 W /m2 . In conclusion, a significant post-operative increase in mucosal cooling correlates well with patients' perception of better nasal patency after NAO surgery.

  15. Outpatient Chronic Obstructive Pulmonary Disease Management: Going for the GOLD.

    PubMed

    Bellinger, Christina R; Peters, Stephen P

    2015-01-01

    Chronic obstructive pulmonary disease (COPD) is the fourth leading cause of death in the United States with a burden of $50 billion in direct health care costs. The Global Initiative for Chronic Obstructive Lung Disease (GOLD) defines airflow obstruction as spirometry where the ratio of forced expiratory volume in the first second to forced vital capacity after bronchodilation is less than 0.70. The guidelines also provided graded recommendations on current therapy for COPD. Treatment can be guided based on severity of disease and severity of symptoms. We review the GOLD guidelines to provide an overview of treatment modalities aimed at improving lung function, reducing hospitalization, and reducing mortality. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  16. Mechanical responses of rat vibrissae to airflow

    PubMed Central

    Yu, Yan S. W.; Graff, Matthew M.; Hartmann, Mitra J. Z.

    2016-01-01

    ABSTRACT The survival of many animals depends in part on their ability to sense the flow of the surrounding fluid medium. To date, however, little is known about how terrestrial mammals sense airflow direction or speed. The present work analyzes the mechanical response of isolated rat macrovibrissae (whiskers) to airflow to assess their viability as flow sensors. Results show that the whisker bends primarily in the direction of airflow and vibrates around a new average position at frequencies related to its resonant modes. The bending direction is not affected by airflow speed or by geometric properties of the whisker. In contrast, the bending magnitude increases strongly with airflow speed and with the ratio of the whisker's arc length to base diameter. To a much smaller degree, the bending magnitude also varies with the orientation of the whisker's intrinsic curvature relative to the direction of airflow. These results are used to predict the mechanical responses of vibrissae to airflow across the entire array, and to show that the rat could actively adjust the airflow data that the vibrissae acquire by changing the orientation of its whiskers. We suggest that, like the whiskers of pinnipeds, the macrovibrissae of terrestrial mammals are multimodal sensors – able to sense both airflow and touch – and that they may play a particularly important role in anemotaxis. PMID:27030774

  17. Respiratory symptoms and airflow limitation in asphalt workers

    PubMed Central

    Randem, B; Ulvestad, B; Burstyn, I; Kongerud, J

    2004-01-01

    Aims: To assess the occurrence of respiratory symptoms and signs of airflow limitations in a group of asphalt workers. Methods: All 64 asphalt workers and a reference group of 195 outdoor construction workers from the same company participated in a cross-sectional study. Spirometric tests and a questionnaire on respiratory symptoms and smoking habits were administered. Respiratory symptoms and lung function were adjusted for age and smoking. Results: The FEV1/FVC% ratio was significantly lower in the asphalt workers than in the referents. Symptoms of eye irritation, chest tightness, shortness of breath on exertion, chest wheezing, physician diagnosed asthma, and chronic obstructive pulmonary disease (COPD) were all significantly more prevalent among the asphalt workers. Conclusion: In asphalt workers there is an increased risk of respiratory symptoms, lung function decline, and COPD compared to other construction workers. PMID:15031397

  18. Characteristics of airflow and particle deposition in COPD current smokers

    NASA Astrophysics Data System (ADS)

    Zou, Chunrui; Choi, Jiwoong; Haghighi, Babak; Choi, Sanghun; Hoffman, Eric A.; Lin, Ching-Long

    2017-11-01

    A recent imaging-based cluster analysis of computed tomography (CT) lung images in a chronic obstructive pulmonary disease (COPD) cohort identified four clusters, viz. disease sub-populations. Cluster 1 had relatively normal airway structures; Cluster 2 had wall thickening; Cluster 3 exhibited decreased wall thickness and luminal narrowing; Cluster 4 had a significant decrease of luminal diameter and a significant reduction of lung deformation, thus having relatively low pulmonary functions. To better understand the characteristics of airflow and particle deposition in these clusters, we performed computational fluid and particle dynamics analyses on representative cluster patients and healthy controls using CT-based airway models and subject-specific 3D-1D coupled boundary conditions. The results show that particle deposition in central airways of cluster 4 patients was noticeably increased especially with increasing particle size despite reduced vital capacity as compared to other clusters and healthy controls. This may be attributable in part to significant airway constriction in cluster 4. This study demonstrates the potential application of cluster-guided CFD analysis in disease populations. NIH Grants U01HL114494 and S10-RR022421, and FDA Grant U01FD005837.

  19. Visualization of airflow growing soap bubbles

    NASA Astrophysics Data System (ADS)

    Al Rahbi, Hamood; Bock, Matthew; Ryu, Sangjin

    2016-11-01

    Visualizing airflow inside growing soap bubbles can answer questions regarding the fluid dynamics of soap bubble blowing, which is a model system for flows with a gas-liquid-gas interface. Also, understanding the soap bubble blowing process is practical because it can contribute to controlling industrial processes similar to soap bubble blowing. In this study, we visualized airflow which grows soap bubbles using the smoke wire technique to understand how airflow blows soap bubbles. The soap bubble blower setup was built to mimic the human blowing process of soap bubbles, which consists of a blower, a nozzle and a bubble ring. The smoke wire was placed between the nozzle and the bubble ring, and smoke-visualized airflow was captured using a high speed camera. Our visualization shows how air jet flows into the growing soap bubble on the ring and how the airflow interacts with the soap film of growing bubble.

  20. [Phonatory airflow in the supraglottal space].

    PubMed

    Müsebeck, K; Rosenberg, H

    1983-05-01

    The phonatory airflow can be measured by means of a hot wire tube placed in the supraglottic space without tying down the tongue. The velocity of airflow above the glottis reaches values around c = 50 to 150 cm/s. The variations in airflow oscillations were recorded. The voice of the person under examination was picked up by a condenser microphone (Bruel & Kjaer No. 2112). According to D'Alembert's wave equation, the sound intensity is related to the velocity of the phonatory air stream. The validity of this statement has been confirmed by repeated testing. The fundamental frequency of voice and of the airflow were analysed synchronously by means of the Nicolet analyser. The air consumption is not utilized for sound production in phonation by breathing. A "hard" or "pressed" voice is associated with diminished or irregular air consumption. The method can be employed in assessing the conditions of phonetic airflow in normal and dysphonic voices.

  1. Identifying possible asthma-COPD overlap syndrome in patients with a new diagnosis of COPD in primary care.

    PubMed

    Baarnes, Camilla Boslev; Kjeldgaard, Peter; Nielsen, Mia; Miravitlles, Marc; Ulrik, Charlotte Suppli

    2017-01-05

    The asthma-chronic obstructive pulmonary disease (COPD) overlap syndrome (ACOS) remains poorly characterised. Our aim was to describe an algorithm for identifying possible ACOS in adults with newly diagnosed COPD in primary care. General practitioners (n=241) consecutively recruited subjects ⩾35 years, with tobacco exposure, at least one respiratory symptom and no previous diagnosis of obstructive lung disease. Possible ACOS was defined as chronic airflow obstruction, i.e., post-bronchodilator (BD) forced expiratory volume 1/forced vital capacity (FEV 1 /FVC) ratio<0.70, combined with wheeze (ACOS wheeze) and/or significant BD reversibility (ACOS BD reversibility). Of 3,875 (50% females, mean age 57 years) subjects screened, 700 (18.1%) were diagnosed with COPD, i.e., symptom(s), tobacco exposure and chronic airflow obstruction. Indications for ACOS were found in 264 (38%) of the COPD patients. The prevalence of ACOS wheeze and ACOS BD reversibility was 27% (n=190) and 16% (n=113), respectively (P<0.001), and only 6% (n=39) of the COPD patients fulfilled both criteria for ACOS. Patients with any ACOS were younger (P=0.04), had more dyspnoea (P<0.001), lower FEV 1 %pred (67% vs. 74%; P<0.001) and lower FEV 1 /FVC ratio (P=0.001) compared with COPD-only patients. Comparing subjects fulfilling both criteria for ACOS with those fulfilling criteria for ACOS wheeze only (n=151) and those fulfilling criteria for ACOS BD reversibility only (n=74) revealed no significant differences. Irrespective of the applied ACOS definition, no significant difference in life-time tobacco exposure was found between ACOS- and COPD-only patients. In subjects with a new diagnosis of COPD, the prevalence of ACOS is high. When screening for COPD in general practice among patients with no previous diagnosis of obstructive lung disease, patients with possible ACOS may be identified by self-reported wheeze and/or BD reversibility.

  2. Management of Acute Exacerbation of Asthma and Chronic Obstructive Pulmonary Disease in the Emergency Department.

    PubMed

    Suau, Salvador J; DeBlieux, Peter M C

    2016-02-01

    Acute asthma and chronic obstructive pulmonary disease (COPD) exacerbations are the most common respiratory diseases requiring emergent medical evaluation and treatment. Asthma and COPD are chronic, debilitating disease processes that have been differentiated traditionally by the presence or absence of reversible airflow obstruction. Asthma and COPD exacerbations impose an enormous economic burden on the US health care budget. In daily clinical practice, it is difficult to differentiate these 2 obstructive processes based on their symptoms, and on their nearly identical acute treatment strategies; major differences are important when discussing anatomic sites involved, long-term prognosis, and the nature of inflammatory markers. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Genetic polymorphism and chronic obstructive pulmonary disease.

    PubMed

    Yuan, Cunhua; Chang, De; Lu, Guangming; Deng, Xiaowei

    2017-01-01

    Chronic obstructive pulmonary disease (COPD) is a common chronic disease, and its morbidity and mortality are increasing. There are many studies that have tried to explain the pathogenesis of COPD from genetic susceptibility, to identify the susceptibility of COPD factors, which play a role in early prevention, early detection and the early treatment. However, it is well known that COPD is an inflammatory disease characterized by incomplete reversible airflow limitation in which genes interact with the environment. In recent years, many studies have proved gene polymorphisms and COPD correlation. However, there is less research on the relationship between COPD and genome-wide association study (GWAS), epigenetics and apoptosis. In this paper, we summarized the correlation between gene level and COPD from the following four aspects: the GWAS, the gene polymorphism, the epigenetics and the apoptosis, and the relationship between COPD and gene is summarized comprehensively.

  4. Reducing airflow energy use in multiple zone vav systems

    NASA Astrophysics Data System (ADS)

    Tukur, Ahmed Gidado

    Variable Air Volume (VAV) systems are the most popular HVAC systems in commercial buildings. VAV systems are designed to deliver airflows at design conditions which only occur for a few hours in a year. Minimizing energy use in VAV systems requires reducing the amount of airflow delivered through the system at part load conditions. Air Handling Unit (AHU) fans are the major drivers of airflow in VAV systems and installing a Variable Frequency Drive (VFD) is the most common method of regulating airflow in VAV systems. A VFD drive does not necessarily save energy without use of an appropriate control strategy. Static pressure reset (SPR) is considered to be the most energy efficient control strategy for AHU fans with VFDs installed. The implementation of SPR however has many challenges; for example, rogue zones--zones which have faulty sensors or failed controls and actuators, system dynamics like hunting and system diversity. By investigating the parameters associated with the implementation of SPR in VAV systems, a new, improved, more stable SPR algorithm was developed and validated. This approach was further improved using Fault Detection and Diagnostics (FDD) to eliminate rogue zones. Additionally, a CO2-Demand Control Ventilation (DCV) based minimum airflow control was used to further reduce ventilation airflow and save more energy from SPR. Energy savings ranging from 25% to 51% were recorded in actual buildings with the new SPR algorithm. Finally, a methodology that utilizes historical VAV data was developed to estimate the potential savings that could be realized using SPR. The approach employed first determines an effective system loss coefficient as a function of mean damper position using the historical duct static pressure, VAV damper positions and airflows. Additionally, the historical data is used to identify the maximum mean duct damper position realizable as a result of insuring a sufficient number of VAVs are fully open at any time. Savings are

  5. A Prototype Flight-Deck Airflow Hazard Visualization System

    NASA Technical Reports Server (NTRS)

    Aragon, Cecilia R.

    2004-01-01

    Airflow hazards such as turbulence, vortices, or low-level wind shear can pose a threat to landing aircraft and are especially dangerous to helicopters. Because pilots usually cannot see airflow, they may be unaware of the extent of the hazard. We have developed a prototype airflow hazard visual display for use in helicopter cockpits to alleviate this problem. We report on the results of a preliminary usability study of our airflow hazard visualization system in helicopter-shipboard operations.

  6. Airflow Hazard Visualization for Helicopter Pilots: Flight Simulation Study Results

    NASA Technical Reports Server (NTRS)

    Aragon, Cecilia R.; Long, Kurtis R.

    2005-01-01

    Airflow hazards such as vortices or low level wind shear have been identified as a primary contributing factor in many helicopter accidents. US Navy ships generate airwakes over their decks, creating potentially hazardous conditions for shipboard rotorcraft launch and recovery. Recent sensor developments may enable the delivery of airwake data to the cockpit, where visualizing the hazard data may improve safety and possibly extend ship/helicopter operational envelopes. A prototype flight-deck airflow hazard visualization system was implemented on a high-fidelity rotorcraft flight dynamics simulator. Experienced helicopter pilots, including pilots from all five branches of the military, participated in a usability study of the system. Data was collected both objectively from the simulator and subjectively from post-test questionnaires. Results of the data analysis are presented, demonstrating a reduction in crash rate and other trends that illustrate the potential of airflow hazard visualization to improve flight safety.

  7. Temperature-controlled airflow ventilation in operating rooms compared with laminar airflow and turbulent mixed airflow.

    PubMed

    Alsved, M; Civilis, A; Ekolind, P; Tammelin, A; Andersson, A Erichsen; Jakobsson, J; Svensson, T; Ramstorp, M; Sadrizadeh, S; Larsson, P-A; Bohgard, M; Šantl-Temkiv, T; Löndahl, J

    2018-02-01

    To evaluate three types of ventilation systems for operating rooms with respect to air cleanliness [in colony-forming units (cfu/m 3 )], energy consumption and comfort of working environment (noise and draught) as reported by surgical team members. Two commonly used ventilation systems, vertical laminar airflow (LAF) and turbulent mixed airflow (TMA), were compared with a newly developed ventilation technique, temperature-controlled airflow (T c AF). The cfu concentrations were measured at three locations in an operating room during 45 orthopaedic procedures: close to the wound (<40cm), at the instrument table and peripherally in the room. The operating team evaluated the comfort of the working environment by answering a questionnaire. LAF and T c AF, but not TMA, resulted in less than 10cfu/m 3 at all measurement locations in the room during surgery. Median values of cfu/m 3 close to the wound (250 samples) were 0 for LAF, 1 for T c AF and 10 for TMA. Peripherally in the room, the cfu concentrations were lowest for T c AF. The cfu concentrations did not scale proportionally with airflow rates. Compared with LAF, the power consumption of T c AF was 28% lower and there was significantly less disturbance from noise and draught. T c AF and LAF remove bacteria more efficiently from the air than TMA, especially close to the wound and at the instrument table. Like LAF, the new T c AF ventilation system maintained very low levels of cfu in the air, but T c AF used substantially less energy and provided a more comfortable working environment than LAF. This enables energy savings with preserved air quality. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. Bronchial obstruction secondary to idiopathic scoliosis in a child: a case report

    PubMed Central

    Alotaibi, Saad; Harder, James; Spier, Sheldon

    2008-01-01

    Introduction Patients with severe idiopathic scoliosis are reported to have significant pulmonary complications, including recurrent chest infections, alveolar hypoventilation and respiratory failure. Case presentation We report a case of a 13-year-old boy with moderate-to-severe scoliosis resulting in torsion or twisting of the bronchus intermedius, which contributed to airflow obstruction defects, as revealed by both spirometry and bronchoscopy. Conclusion We recommend that inspection of the shape of the maximal expiratory flow-volume loop obtained from spirometry, as well as other parameters suggestive of obstructive lung disease, may be important in children with scoliosis. To the best of the authors' knowledge, this is the first report of a child in which pulmonary function testing and direct visualization via a flexible bronchoscope have been used to characterize intrathoracic large airway obstruction. PMID:18498624

  9. Occupation, smoking, and chronic obstructive respiratory disorders: a cross sectional study in an industrial area of Catalonia, Spain

    PubMed Central

    Jaén, Ángeles; Zock, Jan Paul; Kogevinas, Manolis; Ferrer, Antonio; Marín, Albert

    2006-01-01

    Background Few studies have investigated the independent effects of occupational exposures and smoking on chronic bronchitis and airflow obstruction. We assessed the association between lifetime occupational exposures and airflow obstruction in a cross-sectional survey in an urban-industrial area of Catalonia, Spain. Methods We interviewed 576 subjects of both sexes aged 20–70 years (response rate 80%) randomly selected from census rolls, using the ATS questionnaire. Forced spirometry was performed by 497 subjects according to ATS normative. Results Lifetime occupational exposure to dust, gases or fumes was reported by 52% of the subjects (63% in men, 41% in women). Textile industry was the most frequently reported job in relation to these exposures (39%). Chronic cough, expectoration and wheeze were more prevalent in exposed subjects with odds ratios ranging from 1.7 to 2.0 being highest among never-smokers (2.1 to 4.3). Lung function differences between exposed and unexposed subjects were dependent on duration of exposure, but not on smoking habits. Subjects exposed more than 15 years to dusts, gases or fumes had lower lung function values (FEV1 -80 ml, 95% confidence interval (CI) -186 to 26; MMEF -163 ml, CI -397 to 71; FEV1/FVC ratio -1.7%, CI -3.3 to -0.2) than non-exposed. Conclusion Chronic bronchitis symptoms and airflow obstruction are associated with occupational exposures in a population with a high employment in the textile industry. Lung function impairment was related to the duration of occupational exposure, being independent of the effect of smoking. PMID:16476167

  10. Pneumonia risk with inhaled fluticasone furoate and vilanterol in COPD patients with moderate airflow limitation: The SUMMIT trial.

    PubMed

    Crim, Courtney; Calverley, Peter M A; Anderson, Julie A; Holmes, Andrew P; Kilbride, Sally; Martinez, Fernando J; Brook, Robert D; Newby, David E; Yates, Julie C; Celli, Bartolomé R; Vestbo, Jørgen

    2017-10-01

    Pneumonia risk with inhaled corticosteroid use in chronic obstructive pulmonary disease (COPD) has not been thoroughly assessed in patients with moderate airflow limitation. To determine the incidence of pneumonia and risk factors in COPD patients with moderate airflow limitation who had, or were at high risk for cardiovascular disease. In the Study to Understand Mortality and MorbidITy in COPD (SUMMIT), 16,590 subjects with moderate airflow limitation (50% ≤ FEV 1  ≤ 70% predicted) and heightened cardiovascular risk were randomized double-blind 1:1:1:1 to inhaled once-daily vilanterol 25 μg (VI), fluticasone furoate 100 μg (FF), vilanterol 25 μg combined with 100 μg fluticasone furoate (FF/VI), or matched placebo. In a pre-specified analysis, we assessed investigator-reported adverse pneumonia events, and independently-adjudicated fatal events. The safety population comprised 16,568 subjects who actually received study medication. There were 1017 pneumonia events reported from 842 subjects. For placebo, FF, VI and FF/VI, reported pneumonia incidence was 5%, 5%, 4% and 6%, respectively. When adjusted for time on treatment, event rates were similar in the placebo, FF and FF/VI containing arms (3.84, 4.24 and 3.95/100 treatment years, respectively) but lower in the VI group (2.77/100 treatment years). Risk factors for pneumonia risk included: greater degree of airflow limitation (i.e. FEV 1 <60% predicted), prior exacerbation history, and BMI <25 kg/m 2 . In contrast to previous studies in patients with severe disease, increased pneumonia risk with inhaled corticosteroid use was not evident in COPD subjects with moderate airflow limitation and heightened cardiovascular risk. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Cognitive status among patients with chronic obstructive pulmonary disease

    PubMed Central

    Roncero, Carlos; Campuzano, Ana Isabel; Quintano, Jose Antonio; Molina, Jesús; Pérez, Joselín; Miravitlles, Marc

    2016-01-01

    Purpose We investigated the association between cognitive impairment and chronic obstructive pulmonary disease (COPD), taking into account demographic and clinical variables evaluated during routine practice. Patients and methods We performed a post hoc analysis of a cross-sectional study that included subjects with stable COPD. Sociodemographic and clinical information was recorded using the Body mass index, airflow Obstruction, Dyspnea and Exacerbations index and the Charlson comorbidity index. Cognitive performance was studied by the mini-mental state examination, with a score less than 27 indicating clinical impairment. Depressive symptoms, physical activity, and quality of life (EuroQoL-5 dimensions and COPD Assessment Test) were also evaluated. Results The analysis included 940 subjects. The prevalence of cognitive impairment was 39.4%. Multivariate logistic regression models revealed that cognitive impairment was associated with educational level (odds ratio [OR] =0.096, 95% confidence interval [CI] =0.011–0.447) and poorer quality of life measured by the EuroQoL-5 dimensions social tariff (OR =0.967, 95% CI =0.950–0.983). When questionnaires were not included in the analysis, cognitive impairment was associated with educational level (OR =0.063, 95% CI =0.010–0.934), number of exacerbations (OR =11.070, 95% CI =1.450–84.534), Body mass index, airflow Obstruction, Dyspnea and Exacerbations index score (OR =1.261, 95% CI =1.049–1.515), and the Charlson comorbidity index (OR =1.412, 95% CI =1.118–1.783). Conclusion Cognitive impairment is common in COPD and is associated with low educational level, higher disease severity, and increased comorbidity. This could have therapeutic implications for this population. PMID:27042043

  12. Using Computational Fluid Dynamics to examine airflow characteristics in Empty Nose Syndrome

    NASA Astrophysics Data System (ADS)

    Flint, Tim; Esmaily-Moghadam, Mahdi; Thamboo, Andrew; Velasquez, Nathalia; Nayak, Jayakar V.; Sellier, Mathieu; Moin, Parviz

    2016-11-01

    The enigmatic disorder, empty nose syndrome (ENS), presents with a complex subjective symptom profile despite objectively patent nasal airways, and recent reports suggest that surgical augmentation of the nasal airway can improve quality of life and ENS-related complaints. In this study, computational fluid dynamics (CFD) was performed both prior to, and following, inferior turbinate augmentation to model the resultant changes in airflow patterns and better understand the pathophysiology of ENS. An ENS patient with marked reduction in ENS symptoms following turbinate augmentation was identified, and pre- and post-operative CT imaging was collected. A Finite element framework with the variational multiscale method (Esmaily-Moghadam, Comput. Methods Appl. Mech. Engrg. 2015) was used to compute the airflow, temperature, and moisture transport through the nasal cavity. Comparison of the CFD results following corrective surgery showed higher levels of airflow turbulence. Augmentation produced 50%, 25%, and 25% increases in root mean square pressure, wall shear stress, and heat flux respectively. These results provide insight into the changes in nasal airflow characteristics attainable through surgical augmentation, and by extension, how nasal airflow patterns may be distorted in the 'overly patent' airway of ENS patients. Supported by Stanford University CTR and Fulbright New Zealand.

  13. Saber-sheath trachea as a marker of severe airflow obstruction in chronic obstructive pulmonary disease.

    PubMed

    Ciccarese, Federica; Poerio, Antonio; Stagni, Silvia; Attinà, Domenico; Fasano, Luca; Carbonara, Paolo; Bacchi Reggiani, Maria Letizia; Zompatori, Maurizio

    2014-02-01

    Saber-sheath trachea is a specific radiographic parameter for chronic obstructive pulmonary disease (COPD), which consists of marked coronal narrowing associated with sagittal widening (tracheal index <2/3-0.67). The aim of this study was to investigate the correlation between saber-sheath trachea and clinical-radiological findings in a group of patients with COPD of varying severity. We evaluated the chest radiographs of 71 patients with COPD distributed as follows: GOLD class I, 8/71 (11.3 %); class II, 34/71 (47.9 %); class III, 16/71(22.5 %); class IV, 13/71 (18.3 %). In 52/71 (73.2 %) patients we also evaluated chest computed tomography (CT) scans. We analyzed the prevalence of saber-sheath trachea and its correlation with the Tiffenau index, GOLD stage and radiological signs of COPD. Moreover, we evaluated the sensitivity, specificity and accuracy of chest radiography as compared to CT taken as the gold standard, and the correlation between the radiographic and CT tracheal index. Saber-sheath trachea was found in 18/71 (25.4 %) patients, with a greater prevalence in patients with lower Tiffenau Index (p = 0.02), GOLD stages III-IV and visual severity score 3 (severe) on chest CT. Saber-sheath trachea was not found to be related to other radiological signs of COPD. The sensitivity, specificity and accuracy values of radiography were 72.2, 97.0 and 88.5 %, with perfect concordance between the radiographic and CT tracheal index (p < 0.00001). Saber-sheath trachea is linked to the functional severity of airway obstruction, but not to other radiological signs of COPD. Thus, evaluation of the trachea at chest radiography is strongly recommended.

  14. An update on cardiovascular effects of obstructive sleep apnoea syndrome.

    PubMed

    Uyar, Meral; Davutoglu, Vedat

    2016-09-01

    Obstructive sleep apnoea syndrome is an important health problem which may cause or worsen systemic diseases. Chronic intermittent hypoxia during repetitive airflow cessations may cause endothelial dysfunction. Sleep apnoea is also shown to be associated with hypercoagulability which may be due to decreased nitric oxide levels and impaired vasodilatation. Endothelial dysfunction, increased systemic inflammation, sympathetic nervous system activation, increased oxidative stress and dysglycaemia may all contribute to cardiovascular processes such as hypertension, arrhythmia, stroke, heart failure and coronary artery disease in patients with obstructive sleep apnoea. Treatment approaches in patients with obstructive sleep apnoea mainly focus on maintaining upper airway patency either with positive airway pressure devices or upper airway appliances. Strategies involving positive airway pressure therapy are associated with decreased morbidity and mortality. Obstructive sleep apnoea should be suspected as an underlying mechanism in patients with cardiovascular disease and warrants appropriate treatment. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  15. A Novel Spirometric Measure Identifies Mild COPD Unidentified by Standard Criteria.

    PubMed

    Dilektasli, Asli Gorek; Porszasz, Janos; Casaburi, Richard; Stringer, William W; Bhatt, Surya P; Pak, Youngju; Rossiter, Harry B; Washko, George; Castaldi, Peter J; Estepar, Raul San Jose; Hansen, James E

    2016-11-01

    In chronic obstructive pulmonary disease, both smaller and larger airways are affected. FEV 1 mainly reflects large airways obstruction, while the later fraction of forced exhalation reflects reduction in terminal expiratory flow. In this study, the objective was to evaluate the relationship between spirometric ratios, including the ratio of forced expiratory volume in 3 and 6 seconds (FEV 3 /FEV 6 ), and small airways measures and gas trapping at quantitative chest CT scanning, and clinical outcomes in the Genetic Epidemiology of COPD (COPDGene) cohort. Seven thousand eight hundred fifty-three current and ex-smokers were evaluated for airflow obstruction by using recently defined linear iteratively derived equations of Hansen et al to determine lower limit of normal (LLN) equations for prebronchodilator FEV 1 /FVC, FEV 1 /FEV 6 , FEV 3 /FEV 6 , and FEV 3 /FVC. General linear and ordinal regression models were applied to the relationship between prebronchodilator spirometric and radiologic and clinical data. Of the 10,311 participants included in the COPDGene phase I study, participants with incomplete quantitative CT scanning or relevant spirometric data were excluded, resulting in 7,853 participants in the present study. Of 4,386 participants with FEV 1 /FVC greater than or equal to the LLN, 15.4% had abnormal FEV 3 /FEV 6 . Compared with normal FEV 3 /FEV 6 and FEV 1 /FVC, abnormal FEV 3 /FEV 6 was associated with significantly greater gas trapping; St. George's Respiratory Questionnaire score; modified Medical Research Council dyspnea score; and BMI, airflow obstruction, dyspnea, and exercise index and with shorter 6-min walking distance (all P < .0001) but not with CT scanning evidence of emphysema. Current and ex-smokers with prebronchodilator FEV 3 /FEV 6 less than the LLN as the sole abnormality identifies a distinct population with evidence of small airways disease in quantitative CT scanning, impaired indexes of physical function and quality of life

  16. Airflow elicits a spider's jump towards airborne prey. I. Airflow around a flying blowfly

    PubMed Central

    Klopsch, Christian; Kuhlmann, Hendrik C.; Barth, Friedrich G.

    2012-01-01

    The hunting spider Cupiennius salei uses airflow generated by flying insects for the guidance of its prey-capture jump. We investigated the velocity field of the airflow generated by a freely flying blowfly close to the flow sensors on the spider's legs. It shows three characteristic phases (I–III). (I) When approaching, the blowfly induces an airflow signal near the spider with only little fluctuation (0.013 ± 0.006 m s−1) and a strength that increases nearly exponentially with time (maximum: 0.164 ± 0.051 m s−1 s.d.). The spider detects this flow while the fly is still 38.4 ± 5.6 mm away. The fluctuation of the airflow above the sensors increases linearly up to 0.037 m s−1 with the fly's altitude. Differences in the time of arrival and intensity of the fly signal at different legs probably inform the spider about the direction to the prey. (II) Phase II abruptly follows phase I with a much higher degree of fluctuation (fluctuation amplitudes: 0.114 ± 0.050 m s−1). It starts when the fly is directly above the sensor and corresponds to the time-dependent flow in the wake below and behind the fly. Its onset indicates to the spider that its prey is now within reach and triggers its jump. The spider derives information on the fly's position from the airflow characteristics, enabling it to properly time its jump. The horizontal velocity of the approaching fly is reflected by the time of arrival differences (ranging from 0.038 to 0.108 s) of the flow at different legs and the exponential velocity growth rate (16–79 s−1) during phase I. (III) The air flow velocity decays again after the fly has passed the spider. PMID:22572032

  17. Lung function and airway obstruction: associations with circulating markers of cardiac function and incident heart failure in older men—the British Regional Heart Study

    PubMed Central

    Wannamethee, S Goya; Shaper, A Gerald; Papacosta, Olia; Lennon, Lucy; Welsh, Paul; Whincup, Peter H

    2016-01-01

    Aims The association between lung function and cardiac markers and heart failure (HF) has been little studied in the general older population. We have examined the association between lung function and airway obstruction with cardiac markers N-terminal pro-brain natriuretic peptide (NT-proBNP) and cardiac troponin T (cTnT) and risk of incident HF in older men. Methods and results Prospective study of 3242 men aged 60–79 years without prevalent HF or myocardial infarction followed up for an average period of 13 years, in whom 211 incident HF cases occurred. Incident HF was examined in relation to % predicted FEV1 and FVC. The Global Initiative on Obstructive Lung Diseases spirometry criteria were used to define airway obstruction. Reduced FEV1, but not FVC in the normal range, was significantly associated with increased risk of HF after adjustment for established HF risk factors including inflammation. The adjusted HRs comparing men in the 6–24th percentile with the highest quartile were 1.91 (1.24 to 2.94) and 1.30 (0.86 to 1.96) for FEV1 and FVC, respectively. FEV1 and FVC were inversely associated with NT-proBNP and cTnT, although the association between FEV1 and incident HF remained after adjustment for NT-proBNP and cTnT. Compared with normal subjects (FEV1/FVC ≥0.70 and FVC≥80%), moderate or severe (FEV1/FVC <0.70 and FEV1 <80%) airflow obstruction was independently associated with HF ((adjusted relative risk 1.59 (1.08 to 2.33)). Airflow restriction (FEV1/FVC ≥0.70 and FVC <80%) was not independently associated with HF. Conclusions Reduced FEV1 reflecting airflow obstruction is associated with cardiac dysfunction and increased risk of incident HF in older men. PMID:26811343

  18. Effects of Forced Air Warming on Airflow around the Operating Table.

    PubMed

    Shirozu, Kazuhiro; Kai, Tetsuya; Setoguchi, Hidekazu; Ayagaki, Nobuyasu; Hoka, Sumio

    2018-01-01

    Forced air warming systems are used to maintain body temperature during surgery. Benefits of forced air warming have been established, but the possibility that it may disturb the operating room environment and contribute to surgical site contamination is debated. The direction and speed of forced air warming airflow and the influence of laminar airflow in the operating room have not been reported. In one institutional operating room, we examined changes in airflow speed and direction from a lower-body forced air warming device with sterile drapes mimicking abdominal surgery or total knee arthroplasty, and effects of laminar airflow, using a three-dimensional ultrasonic anemometer. Airflow from forced air warming and effects of laminar airflow were visualized using special smoke and laser light. Forced air warming caused upward airflow (39 cm/s) in the patient head area and a unidirectional convection flow (9 to 14 cm/s) along the ceiling from head to foot. No convection flows were observed around the sides of the operating table. Downward laminar airflow of approximately 40 cm/s counteracted the upward airflow caused by forced air warming and formed downward airflow at 36 to 45 cm/s. Downward airflows (34 to 56 cm/s) flowing diagonally away from the operating table were detected at operating table height in both sides. Airflow caused by forced air warming is well counteracted by downward laminar airflow from the ceiling. Thus it would be less likely to cause surgical field contamination in the presence of sufficient laminar airflow.

  19. Analysis of electrocardiogram in chronic obstructive pulmonary disease patients.

    PubMed

    Lazović, Biljana; Svenda, Mirjana Zlatković; Mazić, Sanja; Stajić, Zoran; Delić, Marina

    2013-01-01

    Chronic obstructive pulmonary disease is the fourth leading cause of mortality worldwide. It is defined as a persistent airflow limitation usually progressive and not fully reversible to treatment. The diagnosis of chronic obstructive pulmonary disease and severity of disease is confirmed by spirometry. Chronic obstructive pulmonary disease produces electrical changes in the heart which shows characteristic electrocardiogram pattern. The aim of this study was to observe and evaluate diagnostic values of electrocardiogram changes in chronic obstructive pulmonary disease patients with no other comorbidity. We analyzed 110 electrocardiogram findings in clinically stable chronic obstructive pulmonary disease patients and evaluated the forced expiratory volume in the first second, ratio of forces expiratory volume in the first second to the fixed vital capacity, chest radiographs and electrocardiogram changes such as p wave height, QRS axis and voltage, right bundle branch block, left bundle branch block, right ventricular hypertrophy, T wave inversion in leads V1-V3, S1S2S3 syndrome, transition zone in praecordial lead and QT interval. We found electrocardiogram changes in 64% patients, while 36% had normal electrocardiogram. The most frequent electrocardiogram changes observed were transition zone (76.36%) low QRS (50%) and p pulmonale (14.54%). Left axis deviation was observed in 27.27% patients. Diagnostic values of electrocardiogram in patients with chronic obstructive pulmonary disease suggest that chronic obstructive pulmonary disease patients should be screened electrocardiographically in addition to other clinical investigations.

  20. Non-smoking Chronic Obstructive Pulmonary Disease Attributed to Occupational Exposure to Silica Dust.

    PubMed

    Tsuchiya, Kazuo; Toyoshima, Mikio; Kamiya, Yosuke; Nakamura, Yutaro; Baba, Satoshi; Suda, Takafumi

    2017-01-01

    An 85-year-old, never-smoking man presented with exertional dyspnea. He had been exposed to silica dust in the work place. Chest computed tomography revealed bronchial wall thickening without emphysema. A pulmonary function test showed airflow obstruction without impaired gas transfer. Airway hyperresponsiveness and reversibility were not evident. A transbronchial lung biopsy showed findings suggestive of mineral dust exposure, such as fibrosis and slight pigmentation of bronchioles. He was diagnosed with non-smoking chronic obstructive pulmonary disease (COPD) due to occupational exposure to silica dust. His symptoms were improved using an inhaled long-acting bronchodilator. The clinical characteristics of non-smoking COPD are discussed in this report.

  1. Detection of Mouse Cough Based on Sound Monitoring and Respiratory Airflow Waveforms

    PubMed Central

    Chen, Liyan; Lai, Kefang; Lomask, Joseph Mark; Jiang, Bert; Zhong, Nanshan

    2013-01-01

    Detection for cough in mice has never yielded clearly audible sounds, so there is still a great deal of debates as to whether mice can cough in response to tussive stimuli. Here we introduce an approach for detection of mouse cough based on sound monitoring and airflow signals. 40 Female BALB/c mice were pretreated with normal saline, codeine, capasazepine or desensitized with capsaicin. Single mouse was put in a plethysmograph, exposed to aerosolized 100 µmol/L capsaicin for 3 min, followed by continuous observation for 3 min. Airflow signals of total 6 min were recorded and analyzed to detect coughs. Simultaneously, mouse cough sounds were sensed by a mini-microphone, monitored manually by an operator. When manual and automatic detection coincided, the cough was positively identified. Sound and sound waveforms were also recorded and filtered for further analysis. Body movements were observed by operator. Manual versus automated counts were compared. Seven types of airflow signals were identified by integrating manual and automated monitoring. Observation of mouse movements and analysis of sound waveforms alone did not produce meaningful data. Mouse cough numbers decreased significantly after all above drugs treatment. The Bland-Altman and consistency analysis between automatic and manual counts was 0.968 and 0.956. The study suggests that the mouse is able to present with cough, which could be detected by sound monitoring and respiratory airflow waveform changes. PMID:23555643

  2. Health status perception and airflow obstruction in five Latin American cities: the PLATINO study.

    PubMed

    Montes de Oca, Maria; Tálamo, Carlos; Halbert, Ronald J; Perez-Padilla, Rogelio; Lopez, Maria Victorina; Muiño, Adriana; Jardim, José Roberto B; Valdivia, Gonzalo; Pertuzé, Julio; Moreno, Dolores; Menezes, Ana Maria B

    2009-09-01

    COPD is a highly prevalent disease but underdiagnosed, undertreated and possibly under-recognized by patients. Limited information exists regarding patients' perception of COPD severity. We compared patients' general health status perception, degree of breathlessness and physical activity limitation with the severity of their respiratory condition measured by airway obstruction, in a population-based sample. We used postbronchodilator FEV(1)/FVC<0.70 to define COPD. Patients' perception of their general health status was derived from the question "in general you would say that your health is: excellent, very good, good, fair or poor?" Spirometry was performed in 5314 subjects: an FEV(1)/FVC ratio below 0.70 was found in 759 subjects. In persons with COPD, general health status decreased with increasing GOLD stages. Over one-half of subjects with stage 2 and one third of those with stages 3 and 4 reported their health status as good to excellent. There was also a disparity between airway obstruction severity and breathlessness intensity. Although the more severe COPD stages were frequently associated with significant compromise of work and everyday activities, patients often tended to provide an optimistic self evaluation of their health status. The discrepancy observed between general health status, dyspnea severity, physical activity limitation and airway obstruction most likely reflect patients' underperception of disease severity, emphasizing the need for improving case-finding measures and multi-component evaluation of COPD subjects.

  3. Identifying individuals with physician-diagnosed chronic obstructive pulmonary disease in primary care electronic medical records: a retrospective chart abstraction study.

    PubMed

    Lee, Theresa M; Tu, Karen; Wing, Laura L; Gershon, Andrea S

    2017-05-15

    Little is known about using electronic medical records to identify patients with chronic obstructive pulmonary disease to improve quality of care. Our objective was to develop electronic medical record algorithms that can accurately identify patients with obstructive pulmonary disease. A retrospective chart abstraction study was conducted on data from the Electronic Medical Record Administrative data Linked Database (EMRALD ® ) housed at the Institute for Clinical Evaluative Sciences. Abstracted charts provided the reference standard based on available physician-diagnoses, chronic obstructive pulmonary disease-specific medications, smoking history and pulmonary function testing. Chronic obstructive pulmonary disease electronic medical record algorithms using combinations of terminology in the cumulative patient profile (CPP; problem list/past medical history), physician billing codes (chronic bronchitis/emphysema/other chronic obstructive pulmonary disease), and prescriptions, were tested against the reference standard. Sensitivity, specificity, and positive/negative predictive values (PPV/NPV) were calculated. There were 364 patients with chronic obstructive pulmonary disease identified in a 5889 randomly sampled cohort aged ≥ 35 years (prevalence = 6.2%). The electronic medical record algorithm consisting of ≥ 3 physician billing codes for chronic obstructive pulmonary disease per year; documentation in the CPP; tiotropium prescription; or ipratropium (or its formulations) prescription and a chronic obstructive pulmonary disease billing code had sensitivity of 76.9% (95% CI:72.2-81.2), specificity of 99.7% (99.5-99.8), PPV of 93.6% (90.3-96.1), and NPV of 98.5% (98.1-98.8). Electronic medical record algorithms can accurately identify patients with chronic obstructive pulmonary disease in primary care records. They can be used to enable further studies in practice patterns and chronic obstructive pulmonary disease management in primary care. NOVEL

  4. The Risk Factors and Clinical Course of Asthma with Fixed Airflow Limitation.

    PubMed

    Pothirat, Chaicharn; Chaiwong, Warawut; Liwsrisakun, Chalerm; Bumroongkit, Chaiwat; Deesomchok, Athavudh; Theerakittikul, Theerakorn; Limsukon, Atikun; Phetsuk, Nittaya

    2016-07-01

    To identify risk factors and clinical course of asthma with fixed airflow limitation. A retrospective case-control study of asthma patients was conducted over a 15-month period. Asthma with fixed airflow limitation patients were defined as chronic asthmatics who had both post-bronchodilator (BD) and on-treatment ratio of forced expiratory in first second (FEV1)/forced vital capacity (FVC) persistently less than 0.7, whereas usual chronic asthma patients had post-BD and/or on-treatment ratio of FEV1/FVC more than 0.7. Serial asthma control tests (ACT), medication used, exacerbations were assessed. The risk factors were analyzed using logistic regression. Clinical characteristics between groups were compared using Student’s t-test and Fisher’s exact test. One hundred twenty from 142 eligible subjects were enrolled. They had asthma with fixed airflow limitation (n = 40) and usual chronic asthma (n = 80). Potential risk factors of asthma with fixed airflow limitation included early disease onset (age <15 years) [(adjusted odd ratio (OR) = 3.9, 95% confidence interval (CI) 1.9-8.3)] with longer disease duration (adjusted OR = 8.4, 95% CI 4.6-15.4 for >30 years). Asthma with fixed airflow limitation patients had lower ACT scores (p<0.001), lower level of asthma control (p<0.001), required more asthma medications (p = 0.002), and higher rates of hospitalization (p = 0.001) than usual chronic asthma. The potential risk factors of asthma with fixed airflow limitation were earlier disease onset and longer disease duration. They had poorer asthma control, more medications needed, and higher rates of exacerbation than usual chronic asthma.

  5. Identifying patients at high risk for obstructive sleep apnoea syndrome in Nigeria: A multicentre observational study.

    PubMed

    Desalu, Olufemi O; Onyedum, Cajetan C; Adeoti, Adekunle O; Fadare, Joseph O; Sanya, Emmanuel O; Fawale, Michael B; Bello, Hamzat A

    2017-06-01

    Obstructive sleep apnoea is associated with significant health consequences. A significant proportion of hospitalized patients at risk for obstructive sleep apnoea were never identified and referred for polysomnography for diagnosis. The objective of this study was to determine the factors associated with high risk for obstructive sleep apnoea and use it to identify patients at risk for the condition in tertiary hospitals in Nigeria. This was a multicentre observational study of adult patients hospitalized in three selected hospitals from 15th January to 17th March 2015. Berlin questionnaire and Epworth sleepiness scale were used to assess for obstructive sleep apnoea risk and excessive daytime sleepiness respectively. Additional questions on traditional risk factors for obstructive sleep apnoea were also obtained. Nine hundred and twenty-six patients were recruited into the study. Respondents' mean age was 44.3 years ± 15.2years, 486 (52.5%) were females and 556 (60.0%) had one or more medical co-morbidity and none of the patients had a previous diagnosis of obstructive sleep apnoea. Factors that were independently associated with high risk for obstructive sleep apnoea include systemic hypertension(aOR-10.33;95%: CI 6.42-16.61), obesity(aOR-7.87;95% CI: 4.33-14.29); excessive daytime sleepiness (aOR-3.77;95% CI :2.28-6.22), tobacco smoking (aOR-2.99;95% CI: 1.76-5.07), snoring in a first-degree relative (aOR-1.83;95% CI: 1.19-2.81); and the use of sedative (aOR-1.82;95% CI: 1.06-3.15). This study shows that patients with systemic hypertension, obesity, excessive daytime sleepiness, history of smoking, snoring in a first-degree relative and use of sedatives are at high risk of obstructive sleep apnoea. None of the patients at high risk had a previous diagnosis of sleep apnoea by a physician, highlighting the diagnostic challenges of this condition. The results of this study will assist health care professionals in early identification of individuals at risk of

  6. Club Cell Protein 16 (CC16) Augmentation: A Potential Disease-modifying Approach for Chronic Obstructive Pulmonary Disease (COPD).

    PubMed

    Laucho-Contreras, Maria E; Polverino, Francesca; Tesfaigzi, Yohannes; Pilon, Aprile; Celli, Bartolome R; Owen, Caroline A

    2016-07-01

    Club cell protein 16 (CC16) is the most abundant protein in bronchoalveolar lavage fluid. CC16 has anti-inflammatory properties in smoke-exposed lungs, and chronic obstructive pulmonary disease (COPD) is associated with CC16 deficiency. Herein, we explored whether CC16 is a therapeutic target for COPD. We reviewed the literature on the factors that regulate airway CC16 expression, its biologic functions and its protective activities in smoke-exposed lungs using PUBMED searches. We generated hypotheses on the mechanisms by which CC16 limits COPD development, and discuss its potential as a new therapeutic approach for COPD. CC16 plasma and lung levels are reduced in smokers without airflow obstruction and COPD patients. In COPD patients, airway CC16 expression is inversely correlated with severity of airflow obstruction. CC16 deficiency increases smoke-induced lung pathologies in mice by its effects on epithelial cells, leukocytes, and fibroblasts. Experimental augmentation of CC16 levels using recombinant CC16 in cell culture systems, plasmid and adenoviral-mediated over-expression of CC16 in epithelial cells or smoke-exposed murine airways reduces inflammation and cellular injury. Additional studies are necessary to assess the efficacy of therapies aimed at restoring airway CC16 levels as a new disease-modifying therapy for COPD patients.

  7. Experimental Investigation of the Induced Airflow of Corona Discharge

    NASA Astrophysics Data System (ADS)

    Huang, Yong; Zhang, Xin; Wang, Xun-Nian; Wang, Wan-Bo; Huang, Zong-Bo; Li, Hua-Xing

    2013-09-01

    In order to improve the acceleration effect of corona discharge acting on air, we present an experimental study on the induced airflow produced by corona discharge between two parallel electrodes. The parameters investigated are the type of electrodes, actuation voltage and the distance in the absence of free airflow. The induced flow velocity is measured directly in the accelerated region using the particle image velocimetry technology. The results show that if corona discharge is not developed into arc discharge, the induced airflow velocity increases nearly linearly with the applied voltage and the maximum induced airflow velocity near the needle electrode reaches 36 m/s. It is expected that in the future, the result can be referred to in the research about effect of active flow control to reach much higher induced airflow speed.

  8. Clinical utility of computed tomographic lung volumes in patients with chronic obstructive pulmonary disease.

    PubMed

    Lee, Jae Seung; Lee, Sang-Min; Seo, Joon Beom; Lee, Sei Won; Huh, Jin Won; Oh, Yeon-Mok; Lee, Sang-Do

    2014-01-01

    Published data concerning the utility of computed tomography (CT)-based lung volumes are limited to correlation with lung function. The aim of this study was to evaluate the clinical utility of the CT expiratory-to-inspiratory lung volume ratio (CT Vratio) by assessing the relationship with clinically relevant outcomes. A total of 75 stable chronic obstructive pulmonary disease (COPD) patients having pulmonary function testing and volumetric CT at full inspiration and expiration were retrospectively evaluated. Inspiratory and expiratory CT lung volumes were measured using in-house software. Correlation of the CT Vratio with patient-centered outcomes, including the modified Medical Research Council (MMRC) dyspnea score, the 6-min walk distance (6MWD), the St. George's Respiratory Questionnaire (SGRQ) score, and multidimensional COPD severity indices, such as the BMI, airflow obstruction, dyspnea, and exercise capacity index (BODE) and age, dyspnea, and airflow obstruction (ADO), were analyzed. The CT Vratio correlated significantly with BMI (r = -0.528, p < 0.001). The CT Vratio was also significantly associated with MMRC dyspnea (r = 0.387, p = 0.001), 6MWD (r = -0.459, p < 0.001), and SGRQ (r = 0.369, p = 0.001) scores. Finally, the CT Vratio had significant correlations with the BODE and ADO multidimensional COPD severity indices (r = 0.605, p < 0.001; r = 0.411, p < 0.001). The CT Vratio had significant correlations with patient-centered outcomes and multidimensional COPD severity indices. © 2013 S. Karger AG, Basel.

  9. Systems biology combining human- and animal-data miRNA and mRNA data identifies new targets in ureteropelvic junction obstruction.

    PubMed

    Papadopoulos, Theofilos; Casemayou, Audrey; Neau, Eric; Breuil, Benjamin; Caubet, Cécile; Calise, Denis; Thornhill, Barbara A; Bachvarova, Magdalena; Belliere, Julie; Chevalier, Robert L; Moulos, Panagiotis; Bachvarov, Dimcho; Buffin-Meyer, Benedicte; Decramer, Stéphane; Auriol, Françoise Conte; Bascands, Jean-Loup; Schanstra, Joost P; Klein, Julie

    2017-03-01

    Although renal fibrosis and inflammation have shown to be involved in the pathophysiology of obstructive nephropathies, molecular mechanisms underlying evolution of these processes remain undetermined. In an attempt towards improved understanding of obstructive nephropathy and improved translatability of the results to clinical practice we have developed a systems biology approach combining omics data of both human and mouse obstructive nephropathy. We have studied in parallel the urinary miRNome of infants with ureteropelvic junction obstruction and the kidney tissue miRNome and transcriptome of the corresponding neonatal partial unilateral ureteral obstruction (UUO) mouse model. Several hundreds of miRNAs and mRNAs displayed changed abundance during disease. Combination of miRNAs in both species and associated mRNAs let to the prioritization of five miRNAs and 35 mRNAs associated to disease. In vitro and in vivo validation identified consistent dysregulation of let-7a-5p and miR-29-3p and new potential targets, E3 ubiquitin-protein ligase (DTX4) and neuron navigator 1 (NAV1), potentially involved in fibrotic processes, in obstructive nephropathy in both human and mice that would not be identified otherwise. Our study is the first to correlate a mouse model of neonatal partial UUO with human UPJ obstruction in a comprehensive systems biology analysis. Our data revealed let-7a and miR-29b as molecules potentially involved in the development of fibrosis in UPJ obstruction via the control of DTX4 in both man and mice that would not be identified otherwise.

  10. Reversible obstructive sleep apnea caused by occupational exposure to guar gum dust.

    PubMed

    Leznoff, A; Haight, J S; Hoffstein, V

    1986-05-01

    This report describes a case of reversible obstructive sleep apnea caused by occupational exposure to an inhaled allergen, guar gum powder. The patient, a pet food plant employee, also experienced severe cough, rhinitis, and conjunctivitis. Skin tests confirmed the specific guar allergy. Pharyngeal cross-sectional area was smaller than normal. Pulmonary function studies, histamine challenge tests, nasal air-flow resistance measurements, and nocturnal polysomnography were performed on 3 separate occasions: while the patient was working at his usual occupation, at the end of a 3-wk holiday, and after a guar dust challenge in an inhalation chamber. Pulmonary function and histamine challenge tests were consistently normal. At the time of the initial tests, nasal resistance was elevated, and nocturnal polysomnography revealed obstructive sleep apnea. After absence from work, obstructive sleep apnea resolved, and the nasal resistance returned to normal. After challenge with guar gum dust, the patient developed increased resistance to nasal air flow, and obstructive sleep apnea reappeared. This case demonstrates that allergy can cause reversible obstructive sleep apnea and that occupational exposure should be considered in the assessment of patients with this disease.

  11. Contamination control in HVAC systems for aseptic processing area. Part I: Case study of the airflow velocity in a unidirectional airflow workstation with computational fluid dynamics.

    PubMed

    Ogawa, M

    2000-01-01

    A unidirectional airflow workstation for processing a sterile pharmaceutical product is required to be "Grade A," according to EU-GMP and WHO-GMP. These regulations have employed the wording of "laminar airflow" for unidirectional airflow, with an unclear definition given. This seems to have allowed many reports to describe discussion of airflow velocity only. The guidance values as to the velocity are expressed in various words of 90 ft/min, 0.45 m/sec, 0.3 m/sec, +/- 20%, or "homogeneous air speed." It has been also little clarified how variation in airflow velocity gives influences on contamination control of a workstation working with varying key characteristics, such as ceiling height, internal heat load, internal particle generation, etc. The present author has revealed following points from a case study using Computational Fluid Dynamics: the airflow characteristic in Grade A area shows no significant changes with varying the velocity of supplied airflow, and the particles generated from the operator will be exhausted outside Grade A area without contamination.

  12. Is there any relationship between right and left hand dominance and right and left nasal airflow dominance?

    PubMed

    Price, A; Eccles, R

    2017-10-01

    Left- or right-handedness is a common human trait, and it has been previously reported that human nasal airflow dominance correlates with hand dominance. Any relationship between hand dominance and nasal airflow dominance would be unusual. This study aimed to measure nasal airflow and look for any relationship to handedness. The modified Glatzel mirror was used to record the dominant nasal passage at 15-minute intervals over a 6-hour period in 29 healthy participants consisting of 15 left-handers and 14 right-handers. In left-handers, the percentage of time that the left nasal passage was dominant ranged from 0 to 100 per cent. In right-handers, the percentage of time that the right nasal passage was dominant ranged from 4.2 to 95.8 per cent. No correlation between nasal airflow dominance and hand dominance was identified. The results do not support the hypothesis that nasal airflow and handedness are related.

  13. Large-scale external validation and comparison of prognostic models: an application to chronic obstructive pulmonary disease.

    PubMed

    Guerra, Beniamino; Haile, Sarah R; Lamprecht, Bernd; Ramírez, Ana S; Martinez-Camblor, Pablo; Kaiser, Bernhard; Alfageme, Inmaculada; Almagro, Pere; Casanova, Ciro; Esteban-González, Cristóbal; Soler-Cataluña, Juan J; de-Torres, Juan P; Miravitlles, Marc; Celli, Bartolome R; Marin, Jose M; Ter Riet, Gerben; Sobradillo, Patricia; Lange, Peter; Garcia-Aymerich, Judith; Antó, Josep M; Turner, Alice M; Han, Meilan K; Langhammer, Arnulf; Leivseth, Linda; Bakke, Per; Johannessen, Ane; Oga, Toru; Cosio, Borja; Ancochea-Bermúdez, Julio; Echazarreta, Andres; Roche, Nicolas; Burgel, Pierre-Régis; Sin, Don D; Soriano, Joan B; Puhan, Milo A

    2018-03-02

    External validations and comparisons of prognostic models or scores are a prerequisite for their use in routine clinical care but are lacking in most medical fields including chronic obstructive pulmonary disease (COPD). Our aim was to externally validate and concurrently compare prognostic scores for 3-year all-cause mortality in mostly multimorbid patients with COPD. We relied on 24 cohort studies of the COPD Cohorts Collaborative International Assessment consortium, corresponding to primary, secondary, and tertiary care in Europe, the Americas, and Japan. These studies include globally 15,762 patients with COPD (1871 deaths and 42,203 person years of follow-up). We used network meta-analysis adapted to multiple score comparison (MSC), following a frequentist two-stage approach; thus, we were able to compare all scores in a single analytical framework accounting for correlations among scores within cohorts. We assessed transitivity, heterogeneity, and inconsistency and provided a performance ranking of the prognostic scores. Depending on data availability, between two and nine prognostic scores could be calculated for each cohort. The BODE score (body mass index, airflow obstruction, dyspnea, and exercise capacity) had a median area under the curve (AUC) of 0.679 [1st quartile-3rd quartile = 0.655-0.733] across cohorts. The ADO score (age, dyspnea, and airflow obstruction) showed the best performance for predicting mortality (difference AUC ADO - AUC BODE = 0.015 [95% confidence interval (CI) = -0.002 to 0.032]; p = 0.08) followed by the updated BODE (AUC BODE updated - AUC BODE = 0.008 [95% CI = -0.005 to +0.022]; p = 0.23). The assumption of transitivity was not violated. Heterogeneity across direct comparisons was small, and we did not identify any local or global inconsistency. Our analyses showed best discriminatory performance for the ADO and updated BODE scores in patients with COPD. A limitation to be addressed in future studies is the extension of MSC

  14. Review on airflow in unsaturated zones induced by natural forcings

    NASA Astrophysics Data System (ADS)

    Kuang, Xingxing; Jiao, Jiu Jimmy; Li, Hailong

    2013-10-01

    Subsurface airflow in unsaturated zones induced by natural forcings is of importance in many environmental and engineering fields, such as environmental remediation, water infiltration and groundwater recharge, coastal soil aeration, mine and tunnel ventilation, and gas exchange between soil and atmosphere. This review synthesizes the published literature on subsurface airflow driven by natural forcings such as atmospheric pressure fluctuations, topographic effect, water table fluctuations, and water infiltration. The present state of knowledge concerning the mechanisms, analytical and numerical models, and environmental and engineering applications related to the naturally occurring airflow is discussed. Airflow induced by atmospheric pressure fluctuations is studied the most because of the applications to environmental remediation and transport of trace gases from soil to atmosphere, which are very important in understanding biogeochemical cycling and global change. Airflow induced by infiltration is also an extensively investigated topic because of its implications in rainfall infiltration and groundwater recharge. Airflow induced by water table fluctuations is important in coastal areas because it plays an important role in coastal environmental remediation and ecological systems. Airflow induced by topographic effect is studied the least. However, it has important applications in unsaturated zone gas transport and natural ventilation of mines and tunnels. Finally, the similarities and differences in the characteristics of the air pressure and airflow are compared and future research efforts are recommended.

  15. Occupational chronic obstructive pulmonary disease: a systematic literature review.

    PubMed

    Omland, Oyvind; Würtz, Else Toft; Aasen, Tor Brøvig; Blanc, Paul; Brisman, Jonas Brisman; Miller, Martin Reginald; Pedersen, Ole Find; Schlünssen, Vivi; Sigsgaard, Torben; Ulrik, Charlotte Suppli; Viskum, Sven

    2014-01-01

    Occupational-attributable chronic obstructive pulmonary disease (COPD) presents a substantial health challenge. Focusing on spirometric criteria for airflow obstruction, this review of occupational COPD includes both population-wide and industry-specific exposures. We used PubMed and Embase to identify relevant original epidemiological peer-reviewed articles, supplemented with citations identified from references in key review articles. This yielded 4528 citations. Articles were excluded for lack of lung function measurement, insufficient occupational exposure classification, lack of either external or internal referents, non-accounting of age or smoking effect, or major analytic inadequacies preventing interpretation of findings. A structured data extraction sheet was used for the remaining 147 articles. Final inclusion was based on a positive qualitative Scottish Intercollegiate Guidelines Network (SIGN) score (≥2+) for study quality, yielding 25 population-wide and 34 industry/occupation-specific studies, 15 on inorganic and 19 on organic dust exposure, respectively. There was a consistent and predominantly significant association between occupational exposures and COPD in 22 of 25 population-based studies, 12 of 15 studies with an inorganic/mineral dust exposure, and 17 of 19 studies on organic exposure, even though the studies varied in design, populations, and the use of measures of exposure and outcome. A nearly uniform pattern of a dose-response relationship between various exposures and COPD was found, adding to the evidence that occupational exposures from vapors, gas, dust, and fumes are risk factors for COPD. There is strong and consistent evidence to support a causal association between multiple categories of occupational exposure and COPD, both within and across industry groups.

  16. Club Cell Protein 16 (CC16) Augmentation: A Potential Disease-modifying Approach for Chronic Obstructive Pulmonary Disease (COPD)

    PubMed Central

    Laucho-Contreras, Maria E.; Polverino, Francesca; Tesfaigzi, Yohannes; Pilon, Aprile; Celli, Bartolome R.; Owen, Caroline A.

    2016-01-01

    Introduction Club cell protein 16 (CC16) is the most abundant protein in bronchoalveolar lavage fluid. CC16 has anti-inflammatory properties in smoke-exposed lungs, and chronic obstructive pulmonary disease (COPD) is associated with CC16 deficiency. Herein, we explored whether CC16 is a therapeutic target for COPD. Areas Covered We reviewed the literature on the factors that regulate airway CC16 expression, its biologic functions and its protective activities in smoke-exposed lungs using PUBMED searches. We generated hypotheses on the mechanisms by which CC16 limits COPD development, and discuss its potential as a new therapeutic approach for COPD. Expert Opinion CC16 plasma and lung levels are reduced in smokers without airflow obstruction and COPD patients. In COPD patients, airway CC16 expression is inversely correlated with severity of airflow obstruction. CC16 deficiency increases smoke-induced lung pathologies in mice by its effects on epithelial cells, leukocytes, and fibroblasts. Experimental augmentation of CC16 levels using recombinant CC16 in cell culture systems, plasmid and adenoviral-mediated over-expression of CC16 in epithelial cells or smoke-exposed murine airways reduces inflammation and cellular injury. Additional studies are necessary to assess the efficacy of therapies aimed at restoring airway CC16 levels as a new disease-modifying therapy for COPD patients. PMID:26781659

  17. American Thoracic Society/National Heart, Lung, and Blood Institute Asthma-Chronic Obstructive Pulmonary Disease Overlap Workshop Report.

    PubMed

    Woodruff, Prescott G; van den Berge, Maarten; Boucher, Richard C; Brightling, Christopher; Burchard, Esteban G; Christenson, Stephanie A; Han, MeiLan K; Holtzman, Michael J; Kraft, Monica; Lynch, David A; Martinez, Fernando D; Reddel, Helen K; Sin, Don D; Washko, George R; Wenzel, Sally E; Punturieri, Antonello; Freemer, Michelle M; Wise, Robert A

    2017-08-01

    Asthma and chronic obstructive pulmonary disease (COPD) are highly prevalent chronic obstructive lung diseases with an associated high burden of disease. Asthma, which is often allergic in origin, frequently begins in infancy or childhood with variable airflow obstruction and intermittent wheezing, cough, and dyspnea. Patients with COPD, in contrast, are usually current or former smokers who present after the age of 40 years with symptoms (often persistent) including dyspnea and a productive cough. On the basis of age and smoking history, it is often easy to distinguish between asthma and COPD. However, some patients have features compatible with both diseases. Because clinical studies typically exclude these patients, their underlying disease mechanisms and appropriate treatment remain largely uncertain. To explore the status of and opportunities for research in this area, the NHLBI, in partnership with the American Thoracic Society, convened a workshop of investigators in San Francisco, California on May 14, 2016. At the workshop, current understanding of asthma-COPD overlap was discussed among clinicians, pathologists, radiologists, epidemiologists, and investigators with expertise in asthma and COPD. They considered knowledge gaps in our understanding of asthma-COPD overlap and identified strategies and research priorities that will advance its understanding. This report summarizes those discussions.

  18. Pitot-tube flowmeter for quantification of airflow during sleep.

    PubMed

    Kirkness, J P; Verma, M; McGinley, B M; Erlacher, M; Schwartz, A R; Smith, P L; Wheatley, J R; Patil, S P; Amis, T C; Schneider, H

    2011-02-01

    The gold-standard pneumotachograph is not routinely used to quantify airflow during overnight polysomnography due to the size, weight, bulkiness and discomfort of the equipment that must be worn. To overcome these deficiencies that have precluded the use of a pneumotachograph in routine sleep studies, our group developed a lightweight, low dead space 'pitot flowmeter' (based on pitot-tube principle) for use during sleep. We aimed to examine the characteristics and validate the flowmeter for quantifying airflow and detecting hypopneas during polysomnography by performing a head-to-head comparison with a pneumotachograph. Four experimental paradigms were utilized to determine the technical performance characteristics and the clinical usefulness of the pitot flowmeter in a head-to-head comparison with a pneumotachograph. In each study (1-4), the pitot flowmeter was connected in series with a pneumotachograph under either static flow (flow generator inline or on a face model) or dynamic flow (subject breathing via a polyester face model or on a nasal mask) conditions. The technical characteristics of the pitot flowmeter showed that, (1) the airflow resistance ranged from 0.065 ± 0.002 to 0.279 ± 0.004 cm H(2)O L(-1) s(-1) over the airflow rates of 10 to 50 L min(-1). (2) On the polyester face model there was a linear relationship between airflow as measured by the pitot flowmeter output voltage and the calibrated pneumotachograph signal a (β(1) = 1.08 V L(-1) s(-1); β(0) = 2.45 V). The clinically relevant performance characteristics (hypopnea detection) showed that (3) when the pitot flowmeter was connected via a mask to the human face model, both the sensitivity and specificity for detecting a 50% decrease in peak-to-peak airflow amplitude was 99.2%. When tested in sleeping human subjects, (4) the pitot flowmeter signal displayed 94.5% sensitivity and 91.5% specificity for the detection of 50% peak-to-peak reductions in pneumotachograph-measured airflow. Our data

  19. Change in airflow among patients with asthma discussing relationship problems with their partners.

    PubMed

    Schmaling, Karen B; Afari, Niloofar; Hops, Hyman; Barnhart, Scott; Buchwald, Dedra

    2009-09-01

    This study examined the covariation of negative emotions with airflow among 48 persons with asthma and their partners as they discussed relationship problems. Measures included self-reported questionnaires, airflow and behavior coded from videotaped discussions. Significantly increased self-reported hostility and statistically but not clinically significant declines in airflow were found post- versus pre-discussion. Self-reported responses to asthma symptoms of more anger and less loneliness predicted lower post-discussion airflow after accounting for pre-discussion airflow. The use of effort-independent measures of airflow and autonomic nervous system monitoring may inform future research regarding the physiological mechanisms through which mood and behavior affect airflow.

  20. Investigation of non-uniform airflow signal oscillation during high frequency chest compression

    PubMed Central

    Sohn, Kiwon; Warwick, Warren J; Lee, Yong W; Lee, Jongwon; Holte, James E

    2005-01-01

    Background High frequency chest compression (HFCC) is a useful and popular therapy for clearing bronchial airways of excessive or thicker mucus. Our observation of respiratory airflow of a subject during use of HFCC showed the airflow oscillation by HFCC was strongly influenced by the nonlinearity of the respiratory system. We used a computational model-based approach to analyse the respiratory airflow during use of HFCC. Methods The computational model, which is based on previous physiological studies and represented by an electrical circuit analogue, was used for simulation of in vivo protocol that shows the nonlinearity of the respiratory system. Besides, airflow was measured during use of HFCC. We compared the simulation results to either the measured data or the previous research, to understand and explain the observations. Results and discussion We could observe two important phenomena during respiration pertaining to the airflow signal oscillation generated by HFCC. The amplitudes of HFCC airflow signals varied depending on spontaneous airflow signals. We used the simulation results to investigate how the nonlinearity of airway resistance, lung capacitance, and inertance of air characterized the respiratory airflow. The simulation results indicated that lung capacitance or the inertance of air is also not a factor in the non-uniformity of HFCC airflow signals. Although not perfect, our circuit analogue model allows us to effectively simulate the nonlinear characteristics of the respiratory system. Conclusion We found that the amplitudes of HFCC airflow signals behave as a function of spontaneous airflow signals. This is due to the nonlinearity of the respiratory system, particularly variations in airway resistance. PMID:15904523

  1. Scaled experiments for improving diagnosis of pathological lower-airway obstruction

    NASA Astrophysics Data System (ADS)

    Liu, Chang; Kiger, Ken; Hariprasad, Daniel; Sul, Bora; Wallqvist, Anders; Reifman, Jaques

    2017-11-01

    Many lung diseases, such as asthma and chronic obstructive pulmonary disease, are characterized by obstructed airflow, particularly, in the lower airway branches in the lung. Existing diagnostic tools cannot detect some diseases due to a lack of instrumentation capable of resolving the flow in the lower airways. Recent developments in MRI techniques using hyperpolarized 3He now permit measurement of velocity profiles within the trachea. Motivated by these advances, we aim to provide a better understanding of the connection between lower-airway obstruction and velocity profiles within the trachea. Specifically, we asked whether the flow deficits created by lower-airway obstructions could be detected in the trachea to permit diagnosis of the pathology. To test this idea, we used refractive index-matched materials to construct a scaled, patient-specific, transparent lung model, and coupled it to 5 independently controlled piston pumps that could generate arbitrary flow histories (healthy or diseased) for the 5 different lung lobes. Results obtained by stereo PIV within various regions of the airway network will be presented documenting the system performance and examining the detectability of under-performing lobes within the tracheal flow profile. This work supported by the Henry M. Jackson Foundation under award #3270.

  2. Current situation of asthma-COPD overlap syndrome (ACOS) in Chinese patients older than 40 years with airflow limitation: rationale and design for a multicenter, cross-sectional trial (study protocol).

    PubMed

    Kang, Jian; Yao, Wanzhen; Cai, Baiqiang; Chen, Ping; Ling, Xia; Shang, Hongyan

    2016-12-01

    Asthma and chronic obstructive pulmonary disease (COPD) are the frequently occurring chronic airway diseases, and the overlapping syndrome observed in the majority of patients has been recently defined as asthma-COPD overlap syndrome (ACOS) by the Global Initiative for Chronic Obstructive Lung (GOLD, 2014) and Global initiative for Asthma (GINA, 2015). The proportion, features, and clinical practice of ACOS still remain elusive in China. We are conducting this multicenter, cross-sectional, observational study (NCT02600221) to investigate the distributions of chronic obstructive diseases in patients >40 years of age with chronic airflow limitation in China along with determination of the main clinical practice and features of these diseases. The study will also explore the factors that may influence the exacerbations and severity of ACOS in Chinese patients (>40 years of age). A total of 2,000 patients (age, ≥40 years; either sex) who are clinically diagnosed as having asthma, COPD/chronic bronchitis/emphysema, or ACOS for at least 12 months with airflow limitation [post-bronchodilator forced expiratory volume in 1 second/forced vital capacity (FEV 1 /FVC): <0.7] will be enrolled from approximately 20 sites in China between December 2015 and December 2016. The proportion of ACOS among patients older than 40 years based on GINA 2015 and GOLD 2014 definitions is the primary variable. Following were the secondary variables: the proportions of COPD and asthma among the patients, distributions of the severity of airflow limitation, distribution of groups according to GOLD 2011 group definition (A, B, C, D), and the distribution of medication by drug class in patients with ACOS, asthma, and COPD. Acute exacerbation history, hospitalization, and severity of ACOS as evaluated using COPD Assessment Test, Asthma Control Questionnaire-5, and Modified British Medical Research Council in patients with ACOS were also assessed. This will be the first study to disseminate

  3. New CFD tools to evaluate nasal airflow.

    PubMed

    Burgos, M A; Sanmiguel-Rojas, E; Del Pino, C; Sevilla-García, M A; Esteban-Ortega, F

    2017-08-01

    Computational fluid dynamics (CFD) is a mathematical tool to analyse airflow. As currently CFD is not a usual tool for rhinologists, a group of engineers in collaboration with experts in Rhinology have developed a very intuitive CFD software. The program MECOMLAND ® only required snapshots from the patient's cross-sectional (tomographic) images, being the output those results originated by CFD, such as airflow distributions, velocity profiles, pressure, temperature, or wall shear stress. This is useful complementary information to cover diagnosis, prognosis, or follow-up of nasal pathologies based on quantitative magnitudes linked to airflow. In addition, the user-friendly environment NOSELAND ® helps the medical assessment significantly in the post-processing phase with dynamic reports using a 3D endoscopic view. Specialists in Rhinology have been asked for a more intuitive, simple, powerful CFD software to offer more quality and precision in their work to evaluate the nasal airflow. We present MECOMLAND ® and NOSELAND ® which have all the expected characteristics to fulfil this demand and offer a proper assessment with the maximum of quality plus safety for the patient. These programs represent a non-invasive, low-cost (as the CT scan is already performed in every patient) alternative for the functional study of the difficult rhinologic case. To validate the software, we studied two groups of patients from the Ear Nose Throat clinic, a first group with normal noses and a second group presenting septal deviations. Wall shear stresses are lower in the cases of normal noses in comparison with those for septal deviation. Besides, velocity field distributions, pressure drop between nasopharynx and the ambient, and flow rates in each nostril were different among the nasal cavities in the two groups. These software modules open up a promising future to simulate the nasal airflow behaviour in virtual surgery intervention scenarios under different pressure or

  4. Structure of the airflow above surface waves

    NASA Astrophysics Data System (ADS)

    Buckley, Marc; Veron, Fabrice

    2016-04-01

    Weather, climate and upper ocean patterns are controlled by the exchanges of momentum, heat, mass, and energy across the ocean surface. These fluxes are, in turn, influenced by the small-scale physics at the wavy air-sea interface. We present laboratory measurements of the fine-scale airflow structure above waves, achieved in over 15 different wind-wave conditions, with wave ages Cp/u* ranging from 1.4 to 66.7 (where Cp is the peak phase speed of the waves, and u* the air friction velocity). The experiments were performed in the large (42-m long) wind-wave-current tank at University of Delaware's Air-Sea Interaction laboratory (USA). A combined Particle Image Velocimetry and Laser Induced Fluorescence system was specifically developed for this study, and provided two-dimensional airflow velocity measurement as low as 100 um above the air-water interface. Starting at very low wind speeds (U10~2m/s), we directly observe coherent turbulent structures within the buffer and logarithmic layers of the airflow above the air-water interface, whereby low horizontal velocity air is ejected away from the surface, and higher velocity fluid is swept downward. Wave phase coherent quadrant analysis shows that such turbulent momentum flux events are wave-phase dependent. Airflow separation events are directly observed over young wind waves (Cp/u*<3.7) and counted using measured vorticity and surface viscous stress criteria. Detached high spanwise vorticity layers cause intense wave-coherent turbulence downwind of wave crests, as shown by wave-phase averaging of turbulent momentum fluxes. Mean wave-coherent airflow motions and fluxes also show strong phase-locked patterns, including a sheltering effect, upwind of wave crests over old mechanically generated swells (Cp/u*=31.7), and downwind of crests over young wind waves (Cp/u*=3.7). Over slightly older wind waves (Cp/u* = 6.5), the measured wave-induced airflow perturbations are qualitatively consistent with linear critical layer

  5. Acute Exacerbations and Lung Function Loss in Smokers with and without Chronic Obstructive Pulmonary Disease.

    PubMed

    Dransfield, Mark T; Kunisaki, Ken M; Strand, Matthew J; Anzueto, Antonio; Bhatt, Surya P; Bowler, Russell P; Criner, Gerard J; Curtis, Jeffrey L; Hanania, Nicola A; Nath, Hrudaya; Putcha, Nirupama; Roark, Sarah E; Wan, Emily S; Washko, George R; Wells, J Michael; Wendt, Christine H; Make, Barry J

    2017-02-01

    Acute exacerbations of chronic obstructive pulmonary disease (COPD) increase the risk of death and drive healthcare costs, but whether they accelerate loss of lung function remains controversial. Whether exacerbations in subjects with mild COPD or similar acute respiratory events in smokers without airflow obstruction affect lung function decline is unknown. To determine the association between acute exacerbations of COPD (and acute respiratory events in smokers without COPD) and the change in lung function over 5 years of follow-up. We examined data on the first 2,000 subjects who returned for a second COPDGene visit 5 years after enrollment. Baseline data included demographics, smoking history, and computed tomography emphysema. We defined exacerbations (and acute respiratory events in those without established COPD) as acute respiratory symptoms requiring either antibiotics or systemic steroids, and severe events by the need for hospitalization. Throughout the 5-year follow-up period, we collected self-reported acute respiratory event data at 6-month intervals. We used linear mixed models to fit FEV 1 decline based on reported exacerbations or acute respiratory events. In subjects with COPD, exacerbations were associated with excess FEV 1 decline, with the greatest effect in Global Initiative for Chronic Obstructive Lung Disease stage 1, where each exacerbation was associated with an additional 23 ml/yr decline (95% confidence interval, 2-44; P = 0.03), and each severe exacerbation with an additional 87 ml/yr decline (95% confidence interval, 23-151; P = 0.008); statistically significant but smaller effects were observed in Global Initiative for Chronic Obstructive Lung Disease stage 2 and 3 subjects. In subjects without airflow obstruction, acute respiratory events were not associated with additional FEV 1 decline. Exacerbations are associated with accelerated lung function loss in subjects with established COPD, particularly those with mild disease

  6. Prognostic validation of the body mass index, airflow obstruction, dyspnea, and exercise capacity (BODE) index in inoperable non-small-cell lung cancer.

    PubMed

    Denehy, Linda; Hornsby, Whitney E; Herndon, James E; Thomas, Samantha; Ready, Neal E; Granger, Catherine L; Valera, Lauren; Kenjale, Aarti A; Eves, Neil D; Jones, Lee W

    2013-12-01

    To investigate the prognostic utility of the body mass index, severity of airflow obstruction, measures of exertional dyspnea, and exercise capacity (BODE) index in patients with inoperable non-small-cell lung cancer (NSCLC). One hundred consecutive patients with inoperable NSCLC and performance status 0 to 3 completed pulmonary function testing, the modified Medical Research Council dyspnea scale, a 6-minute walk test, and body mass index-the multidimensional 10-point BODE index. Cox proportional models were used to estimate the risk of all-cause mortality according to the BODE index with or without adjustment for traditional prognostic factors. Median follow-up was 31.5 months; 61 deaths (61%) were reported during this period. There was a significant univariate association between the BODE index score and mortality (adjusted p(trend) = 0.027). Compared with patients with a BODE index of 0, the adjusted hazard ratio for risk of death was 1.37 (95% confidence interval [CI], 0.74-2.55) for a BODE index of 1, 1.22 (95% CI, 0.45-3.25) for a BODE index of 2, and 2.44 (95% CI, 1.19-4.99) for a BODE index more than 2. The BODE index provided incremental prognostic information beyond that provided traditional markers of prognosis (adjusted p(trend) = 0.051). Every one-point increase in the BODE index, the risk of death increased by 25% (hazard ratio = 1.25; 95% CI, 1.27-4.64). The BODE index is a strong independent predictor of survival in inoperable NSCLC beyond traditional risk factors. Use of this multidimensional tool may improve risk stratification and prognostication in NSCLC.

  7. Creation of an idealized nasopharynx geometry for accurate computational fluid dynamics simulations of nasal airflow in patient-specific models lacking the nasopharynx anatomy

    PubMed Central

    Borojeni, Azadeh A.T.; Frank-Ito, Dennis O.; Kimbell, Julia S.; Rhee, John S.; Garcia, Guilherme J. M.

    2016-01-01

    Virtual surgery planning based on computational fluid dynamics (CFD) simulations has the potential to improve surgical outcomes for nasal airway obstruction (NAO) patients, but the benefits of virtual surgery planning must outweigh the risks of radiation exposure. Cone beam computed tomography (CBCT) scans represent an attractive imaging modality for virtual surgery planning due to lower costs and lower radiation exposures compared with conventional CT scans. However, to minimize the radiation exposure, the CBCT sinusitis protocol sometimes images only the nasal cavity, excluding the nasopharynx. The goal of this study was to develop an idealized nasopharynx geometry for accurate representation of outlet boundary conditions when the nasopharynx geometry is unavailable. Anatomically-accurate models of the nasopharynx created from thirty CT scans were intersected with planes rotated at different angles to obtain an average geometry. Cross sections of the idealized nasopharynx were approximated as ellipses with cross-sectional areas and aspect ratios equal to the average in the actual patient-specific models. CFD simulations were performed to investigate whether nasal airflow patterns were affected when the CT-based nasopharynx was replaced by the idealized nasopharynx in 10 NAO patients. Despite the simple form of the idealized geometry, all biophysical variables (nasal resistance, airflow rate, and heat fluxes) were very similar in the idealized vs. patient-specific models. The results confirmed the expectation that the nasopharynx geometry has a minimal effect in the nasal airflow patterns during inspiration. The idealized nasopharynx geometry will be useful in future CFD studies of nasal airflow based on medical images that exclude the nasopharynx. PMID:27525807

  8. Using reference values to define disease based on the lower limit of normal biased the population attributable fraction, but not the population excess risk: the example of chronic airflow obstruction.

    PubMed

    Burney, Peter; Minelli, Cosetta

    2018-01-01

    The impact of disease on population health is most commonly estimated by the population attributable fraction (PAF), or less commonly by the excess risk, an alternative measure that estimates the absolute risk of disease in the population that can be ascribed to the exposure. Using chronic airflow obstruction as an example, we examined the impact on these estimates of defining disease based on different "normal" values. We estimated PAF and the excess risk in scenarios in which the true rate of disease was 10% in the exposed and 5% in the unexposed, and where either 50% or 20% of the population was exposed. Disease definition was based on a "lower limit of normal", using the 5th, 1st and 0.2nd centile of values in a "normal" population as thresholds to define normality. Where normality is defined by centiles of values in a "normal" population, PAF is strongly influenced by which centile is selected to define normality. This is not true for the population excess risk. Care should be taken when interpreting estimates of PAF when disease is defined from a centile of a normal population. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Development of an Ultrasonic Airflow Measurement Device for Ducted Air

    PubMed Central

    Raine, Andrew B.; Aslam, Nauman; Underwood, Christopher P.; Danaher, Sean

    2015-01-01

    In this study, an in-duct ultrasonic airflow measurement device has been designed, developed and tested. The airflow measurement results for a small range of airflow velocities and temperatures show that the accuracy was better than 3.5% root mean square (RMS) when it was tested within a round or square duct compared to the in-line Venturi tube airflow meter used for reference. This proof of concept device has provided evidence that with further development it could be a low-cost alternative to pressure differential devices such as the orifice plate airflow meter for monitoring energy efficiency performance and reliability of ventilation systems. The design uses a number of techniques and design choices to provide solutions to lower the implementation cost of the device compared to traditional airflow meters. The design choices that were found to work well are the single sided transducer arrangement for a “V” shaped reflective path and the use of square wave transmitter pulses ending with the necessary 180° phase changed pulse train to suppress transducer ringing. The device is also designed so that it does not have to rely on high-speed analogue to digital converters (ADC) and intensive digital signal processing, so could be implemented using voltage comparators and low-cost microcontrollers. PMID:25954952

  10. Respiratory pharmacotherapy use in patients newly diagnosed with chronic obstructive pulmonary disease in a primary care setting in the UK: a retrospective cohort study.

    PubMed

    Wurst, Keele E; Shukla, Amit; Muellerova, Hana; Davis, Kourtney J

    2014-09-01

    This retrospective cohort study aimed to analyze the prescribing practices of general practitioners treating patients with newly diagnosed chronic obstructive pulmonary disease (COPD), and to assess characteristics associated with initial pharmacotherapy. Patients were identified in the General Practice Research Database, a population-based UK electronic medical record (EMR) with data from January 1, 2008 to December 31, 2009. Patient characteristics, prescribed COPD pharmacotherapies (≤12 months before diagnosis and within 3 months following diagnosis), co-morbidities, hospitalizations, and events indicative of a possible COPD exacerbation (≤12 months before diagnosis) were analyzed in 7881 patients with newly diagnosed COPD. Most patients (64.4%) were prescribed COPD pharmacotherapy in the 12 months before diagnosis. Following diagnosis, COPD pharmacotherapy was prescribed within 3 months in 85.0% of patients. Short-acting bronchodilators alone (22.9%) or inhaled corticosteroids + long-acting beta-2 agonists (ICS+LABA, 22.1%) were prescribed most frequently. Compared with other pharmacotherapies, the prevalence of severe airflow limitation was highest in patients prescribed ICS+LABA+long-acting muscarinic antagonists (LAMA). Moderate-to-severe dyspnea was identified most frequently in patients prescribed a LAMA-containing regimen. Patients prescribed an ICS-containing regimen had a higher prevalence of asthma or possible exacerbations recorded in the EMR than those not prescribed ICS. In conclusion, pharmacotherapy prescribed at initial COPD diagnosis varied by disease severity indicators as assessed by airflow limitation, dyspnea, history of asthma, and possible exacerbations. Frequent prescription of COPD pharmacotherapies before the first-recorded COPD diagnosis indicates a delay between obstructive lung disease presentation in primary care practice and assignment of a medical diagnosis.

  11. Identification of subtypes in subjects with mild-to-moderate airflow limitation and its clinical and socioeconomic implications.

    PubMed

    Lee, Jin Hwa; Rhee, Chin Kook; Kim, Kyungjoo; Kim, Jee-Ae; Kim, Sang Hyun; Yoo, Kwang Ha; Kim, Woo Jin; Park, Yong Bum; Park, Hye Yun; Jung, Ki-Suck

    2017-01-01

    The purpose of this study was to identify subtypes in patients with mild-to-moderate airflow limitation and to appreciate their clinical and socioeconomic implications. Subjects who were aged ≥20 years and had forced expiratory volume in 1 second (FEV 1 ) ≥60% predicted and FEV 1 /forced vital capacity <0.7 were selected from the fourth Korea National Health and Nutrition Examination Survey (KNHANES) in 2007-2012. The data were merged to the National Health Insurance reimbursement database during the same period. k-Means clustering was performed to explore subtypes. For clustering analysis, six key input variables - age, body mass index (BMI), FEV 1 % predicted, the presence or absence of self-reported wheezing, smoking status, and pack-years of smoking - were selected. Among a total of 2,140 subjects, five groups were identified through k-means clustering, namely putative "near-normal (n=232)," "asthmatic (n=392)," "chronic obstructive pulmonary disease (COPD) (n=37)," "asthmatic-overlap (n=893)," and "COPD-overlap (n=586)" subtypes. Near-normal group showed the oldest mean age (72±7 years) and highest FEV 1 (102%±8% predicted), and asthmatic group was the youngest (46±9 years). COPD and COPD-overlap groups were male predominant and all current or ex-smokers. While asthmatic group had the lowest prescription rate despite the highest proportion of self-reported wheezing, COPD, asthmatic-overlap, and COPD-overlap groups showed high prescription rate of respiratory medicine. Although COPD group formed only 1.7% of total subjects, they showed the highest mean medical cost and health care utilization, comprising 5.3% of the total medical cost. When calculating a ratio of total medical expense to household income, the mean ratio was highest in the COPD group. Clinical and epidemiological heterogeneities of subjects with mild-to-moderate airflow limitation and a different level of health care utilization by each subtype are shown. Identification of a subtype with

  12. Estimation of Pharyngeal Collapsibility During Sleep by Peak Inspiratory Airflow.

    PubMed

    Azarbarzin, Ali; Sands, Scott A; Taranto-Montemurro, Luigi; Oliveira Marques, Melania D; Genta, Pedro R; Edwards, Bradley A; Butler, James; White, David P; Wellman, Andrew

    2017-01-01

    Pharyngeal critical closing pressure (Pcrit) or collapsibility is a major determinant of obstructive sleep apnea (OSA) and may be used to predict the success/failure of non-continuous positive airway pressure (CPAP) therapies. Since its assessment involves overnight manipulation of CPAP, we sought to validate the peak inspiratory flow during natural sleep (without CPAP) as a simple surrogate measurement of collapsibility. Fourteen patients with OSA attended overnight polysomnography with pneumotachograph airflow. The middle third of the night (non-rapid eye movement sleep [NREM]) was dedicated to assessing Pcrit in passive and active states via abrupt and gradual CPAP pressure drops, respectively. Pcrit is the extrapolated CPAP pressure at which flow is zero. Peak and mid-inspiratory flow off CPAP was obtained from all breaths during sleep (excluding arousal) and compared with Pcrit. Active Pcrit, measured during NREM sleep, was strongly correlated with both peak and mid-inspiratory flow during NREM sleep (r = -0.71, p < .005 and r = -0.64, p < .05, respectively), indicating that active pharyngeal collapsibility can be reliably estimated from simple airflow measurements during polysomnography. However, there was no significant relationship between passive Pcrit, measured during NREM sleep, and peak or mid-inspiratory flow obtained from NREM sleep. Flow measurements during REM sleep were not significantly associated with active or passive Pcrit. Our study demonstrates the feasibility of estimating active Pcrit using flow measurements in patients with OSA. This method may enable clinicians to estimate pharyngeal collapsibility without sophisticated equipment and potentially aid in the selection of patients for non- positive airway pressure therapies. © Sleep Research Society 2016. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  13. Airflow attenuation and bed net utilization: observations from Africa and Asia.

    PubMed

    von Seidlein, Lorenz; Ikonomidis, Konstantin; Bruun, Rasmus; Jawara, Musa; Pinder, Margaret; Knols, Bart Gj; Knudsen, Jakob B

    2012-06-15

    Qualitative studies suggest that bed nets affect the thermal comfort of users. To understand and reduce this discomfort the effect of bed nets on temperature, humidity, and airflow was measured in rural homes in Asia and Africa, as well as in an experimental wind tunnel. Two investigators with architectural training selected 60 houses in The Gambia, Tanzania, Philippines, and Thailand. Data-loggers were used to measure indoor temperatures in hourly intervals over a 12 months period. In a subgroup of 20 houses airflow, temperature and humidity were measured at five-minute intervals for one night from 21.00 to 6.00 hrs inside and outside of bed nets using sensors and omni-directional thermo-anemometers. An investigator set up a bed net with a mesh size of 220 holes per inch 2 in each study household and slept under the bed net to simulate a realistic environment. The attenuation of airflow caused by bed nets of different mesh sizes was also measured in an experimental wind tunnel. The highest indoor temperatures (49.0 C) were measured in The Gambia. During the hottest months of the year the mean temperature at night (9 pm) was between 33.1 C (The Gambia) and 26.2 C (Thailand). The bed net attenuated the airflow from a minimum of 27% (Philippines) to a maximum of 71% (The Gambia). Overall the bed nets reduced airflow compared to un-attenuated airflow from 9 to 4 cm sec-1 or 52% (p<0.001). In all sites, no statistically significant difference in temperature or humidity was detected between the inside and outside of the bed net. Wind tunnel experiments with 11 different mesh-sized bed nets showed an overall reduction in airflow of 64% (range 55 - 71%) compared to un-attenuated airflow. As expected, airflow decreased with increasing net mesh size. Nets with a mesh of 136 holes inch-2 reduced airflow by 55% (mean; range 51 - 73%). A denser net (200 holes inch-2) attenuated airflow by 59% (mean; range 56 - 74%). Despite concerted efforts to increase the uptake of this

  14. Resistance to forced airflow through layers of composting organic material.

    PubMed

    Teixeira, Denis Leocádio; de Matos, Antonio Teixeira; Melo, Evandro de Castro

    2015-02-01

    The objective of this study was to adjust equations to estimate the static pressure gradient of airflow through layers of organic residues submitted to two stages of biochemical degradation, and to evaluate the static pressure drop of airflow thought the material layer. Measurements of static pressure drop in the layers of sugarcane bagasse and coffee husks mixed with poultry litter on day 0 and after 30 days of composting were performed using a prototype with specific airflow rates ranging from 0.02 to 0.13 m(3) s(-1) m(-2). Static pressure gradient and specific airflow rate data were properly fit to the Shedd, Hukill & Ives and Ergun models, which may be used to predict the static pressure gradient of air to be blown through the organic residue layers. However, the Shedd model was that which best represented the phenomenon studied. The static pressure drop of airflow increased as a power of the material layer thickness and showed tendency for decreasing with the biochemical degradation time of the organic material. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Voluntary pulmonary function screening identifies high rates of undiagnosed asymptomatic chronic obstructive pulmonary disease.

    PubMed

    Wang, Shengyu; Gong, Wei; Tian, Yao

    2016-05-01

    Chronic obstructive pulmonary disease (COPD) is projected to be the third leading cause of death by 2020. Early detection and screening may alter the course and prognosis associated with lung disease. We investigated the effectiveness of a voluntary public lung function screening program and factors that had a predictive value for asymptomatic COPD in Xi'an, China. Pulmonary function testing (PFT) was conducted on volunteers recruited from four community centers in Xi'an, China, between July and August 2012. Participants underwent three forced vital capacity maneuvers. The maneuver with the best forced expiratory volume in first second was retained. Participants filled out a medical history and environmental exposure survey before undergoing the PFT. Patients who self-reported lung disease on the health survey were excluded from the analysis. Logistical regression was used to determine associations with airway obstruction. A total of 803 volunteers participated in this study, and 33 subjects were excluded as the participants did not meet the requirements of PFT. Of the 770 volunteers, 44 participants had been diagnosed with chronic respiratory diseases previously, and 144 participants (18.7%) met COPD criteria. Four hundred forty-four participants did not self-report any respiratory symptoms, and the remaining 282 participants self-reported respiratory symptoms. Of the asymptomatic participants, 98 volunteers had PFT results that were consistent with COPD and 68.1% of asymptomatic participants were undiagnosed. A greater percentage of women than men had moderate or severe airway obstruction (p = 0.004).Only smoking status (odds ratio = 2.64, 95% confidence interval 1.20-6.04) was associated with asymptomatic COPD. Voluntary public lung function screening programs in China are likely to identify a large number of undiagnosed, asymptomatic COPD. Smoking status is associated with airway obstruction and a greater percentage of women than men had moderate or severe

  16. Analysis of the interplay between neurochemical control of respiration and upper airway mechanics producing upper airway obstruction during sleep in humans.

    PubMed

    Longobardo, G S; Evangelisti, C J; Cherniack, N S

    2008-02-01

    Increased loop gain (a function of both controller gain and plant gain), which results in instability in feedback control, is of major importance in producing recurrent central apnoeas during sleep but its role in causing obstructive apnoeas is not clear. The purpose of this study was to investigate the role of loop gain in producing obstructive sleep apnoeas. Owing to the complexity of factors that may operate to produce obstruction during sleep, we used a mathematical model to sort them out. The model used was based on our previous model of neurochemical control of breathing, which included the effects of chemical stimuli and changes in alertness on respiratory pattern generator activity. To this we added a model of the upper airways that contained a narrowed section which behaved as a compressible elastic tube and was tethered during inspiration by the contraction of the upper airway dilator muscles. These muscles in the model, as in life, responded to changes in hypoxia, hypercapnia and alertness in a manner similar to the action of the chest wall muscles, opposing the compressive action caused by the negative intraluminal pressure generated during inspiration which was magnified by the Bernoulli Effect. As the velocity of inspiratory airflow increased, with sufficiently large increase in airflow velocity, obstruction occurred. Changes in breathing after sleep onset were simulated. The simulations showed that increases in controller gain caused the more rapid onset of obstructive apnoeas. Apnoea episodes were terminated by arousal. With a constant controller gain, as stiffness decreased, obstructed breaths appeared and periods of obstruction recurred longer after sleep onset before disappearing. Decreased controller gain produced, for example, by breathing oxygen eliminated the obstructive apnoeas resulting from moderate reductions in constricted segment stiffness. This became less effective as stiffness was reduced more. Contraction of the upper airway muscles

  17. Global Initiative for Chronic Obstructive Lung Disease strategy for the diagnosis, management and prevention of chronic obstructive pulmonary disease: an Asia-Pacific perspective.

    PubMed

    2005-01-01

    Chronic obstructive pulmonary disease (COPD) is a major public health problem and its prevalence and mortality are increasing throughout the world, including the Asia-Pacific region. To arrest these worldwide trends, the Global Initiative for Chronic Obstructive Lung Disease (GOLD) Expert Panel's global strategy for the diagnosis, management, and prevention of COPD was published in 2001. Based on recently published clinical trials, the GOLD statement was updated in 2003. The Asia-Pacific COPD Roundtable Group, a taskforce of expert respirologists from the Asia-Pacific region, has recently formulated a consensus statement on implementation of the GOLD strategy for COPD in the Asia-Pacific region. The key issues identified by the COPD Roundtable Group for comment are: (i) where there is no access to spirometry, diagnosis of COPD could be suspected on the basis of history, symptoms and physical signs; (ii) inhaled bronchodilators are the preferred regular treatment for COPD in the region, but oral bronchodilators may be considered if the cost of inhaled bronchodilators is a barrier to treatment; (iii) the use of a Metered Dose Inhaler with spacer in place of a nebulizer is recommended in the treatment of acute airflow obstruction in patients with COPD; (iv) influenza vaccination is recommended for all patients with COPD in communities where there is a high likelihood of Severe Acute Respiratory Syndrome; and (v) simplified pulmonary rehabilitation programmes should be established in areas where comprehensive programmes are unavailable. Physical exercise training and education on smoking cessation should be core elements of any rehabilitation program. In summary, the COPD Roundtable Group supports implementation of the GOLD strategy for the diagnosis, management and prevention of COPD in the Asia-Pacific region, subject to the additions and modifications to the guidelines suggested above.

  18. An In Silico Subject-Variability Study of Upper Airway Morphological Influence on the Airflow Regime in a Tracheobronchial Tree

    PubMed Central

    Chen, Xiaole; Lin, Jiang

    2017-01-01

    Determining the impact of inter-subject variability on airflow pattern and nanoparticle deposition in the human respiratory system is necessary to generate population-representative models, useful for several biomedical engineering applications. Thus, the overall research objective is to quantitatively correlate geometric parameters and coupled transport characteristics of air, vapor, and nanoparticles. Focusing on identifying morphological parameters that significantly influence airflow field and nanoparticle transport, an experimentally validated computational fluid-particle dynamics (CFPD) model was employed to simulate airflow pattern in three human lung-airway configurations. The numerical results will be used to generate guidelines to construct a representative geometry of the human respiratory system. PMID:29144436

  19. Spectral analysis of airflow sounds in patent versus occluded tracheostomy tubes: a pilot study in tracheostomized adult patients.

    PubMed

    Rao, A J; Niwa, H; Watanabe, Y; Fukuta, S; Yanagita, N

    1990-05-01

    Cannula occlusion is a life-threatening postoperative complication of tracheostomy. Current management largely relies on nursing care for prevention of fatalities because no proven mechanical, machine-based support monitoring exists. The objective of this paper was to address the problem of monitoring the state of cannula patency, based on analysis of airflow acoustic spectral patterns in tracheostomized adult patients in the patent and partially occluded cannula. Tracheal airflow sounds were picked up via a condenser microphone air-coupled to the skin just below the tracheal stoma. Signal output from Mic was amplified, high-pass filtered, digital tape-recorded, and analyzed on a mainframe computer. Although airflow frequencies for patient cannulae were predominantly low-pitched (0.1 to 0.3 kHz), occluded tubes had discrete high-pitched spectral peaks (1.3 to 1.6 kHz). These results suggest that frequency analysis of airflow sounds can identify a change in the status of cannula patency.

  20. Real-time visualization and analysis of airflow field by use of digital holography

    NASA Astrophysics Data System (ADS)

    Di, Jianglei; Wu, Bingjing; Chen, Xin; Liu, Junjiang; Wang, Jun; Zhao, Jianlin

    2013-04-01

    The measurement and analysis of airflow field is very important in fluid dynamics. For airflow, smoke particles can be added to visually observe the turbulence phenomena by particle tracking technology, but the effect of smoke particles to follow the high speed airflow will reduce the measurement accuracy. In recent years, with the advantage of non-contact, nondestructive, fast and full-field measurement, digital holography has been widely applied in many fields, such as deformation and vibration analysis, particle characterization, refractive index measurement, and so on. In this paper, we present a method to measure the airflow field by use of digital holography. A small wind tunnel model made of acrylic glass is built to control the velocity and direction of airflow. Different shapes of samples such as aircraft wing and cylinder are placed in the wind tunnel model to produce different forms of flow field. With a Mach-Zehnder interferometer setup, a series of digital holograms carrying the information of airflow filed distributions in different states are recorded by CCD camera and corresponding holographic images are numerically reconstructed from the holograms by computer. Then we can conveniently obtain the velocity or pressure information of the airflow deduced from the quantitative phase information of holographic images and visually display the airflow filed and its evolution in the form of a movie. The theory and experiment results show that digital holography is a robust and feasible approach for real-time visualization and analysis of airflow field.

  1. Unidirectional pulmonary airflow patterns in the savannah monitor lizard.

    PubMed

    Schachner, Emma R; Cieri, Robert L; Butler, James P; Farmer, C G

    2014-02-20

    The unidirectional airflow patterns in the lungs of birds have long been considered a unique and specialized trait associated with the oxygen demands of flying, their endothermic metabolism and unusual pulmonary architecture. However, the discovery of similar flow patterns in the lungs of crocodilians indicates that this character is probably ancestral for all archosaurs--the group that includes extant birds and crocodilians as well as their extinct relatives, such as pterosaurs and dinosaurs. Unidirectional flow in birds results from aerodynamic valves, rather than from sphincters or other physical mechanisms, and similar aerodynamic valves seem to be present in crocodilians. The anatomical and developmental similarities in the primary and secondary bronchi of birds and crocodilians suggest that these structures and airflow patterns may be homologous. The origin of this pattern is at least as old as the split between crocodilians and birds, which occurred in the Triassic period. Alternatively, this pattern of flow may be even older; this hypothesis can be tested by investigating patterns of airflow in members of the outgroup to birds and crocodilians, the Lepidosauromorpha (tuatara, lizards and snakes). Here we demonstrate region-specific unidirectional airflow in the lungs of the savannah monitor lizard (Varanus exanthematicus). The presence of unidirectional flow in the lungs of V. exanthematicus thus gives rise to two possible evolutionary scenarios: either unidirectional airflow evolved independently in archosaurs and monitor lizards, or these flow patterns are homologous in archosaurs and V. exanthematicus, having evolved only once in ancestral diapsids (the clade encompassing snakes, lizards, crocodilians and birds). If unidirectional airflow is plesiomorphic for Diapsida, this respiratory character can be reconstructed for extinct diapsids, and evolved in a small ectothermic tetrapod during the Palaeozoic era at least a hundred million years before the

  2. Multidimensional approach for the proper management of a complex chronic patient with chronic obstructive pulmonary disease.

    PubMed

    Rogliani, Paola; Brusasco, Vito; Fabbri, Leonardo; Ungar, Andrea; Muscianisi, Elisa; Barisone, Ilaria; Corsini, Alberto; De Angelis, Giuseppe

    2018-02-01

    Chronic obstructive pulmonary disease (COPD) is frequently associated with comorbidities occurring either independently or as consequences of COPD. Areas covered: This review examines the interactions between the pathophysiology of COPD and the most frequent comorbidities, and highlights the need for multidimensional clinical strategies to manage COPD patients with comorbidities. Expert commentary: Most COPD patients need to be approached in a complex and multifactorial scenario. The diagnosis of COPD is necessarily based on the presence of chronic respiratory symptoms and poorly reversible airflow obstruction, but exacerbations and comorbidities need to be considered in the evaluation of disease severity and prognosis in individual patients. More importantly, defining the precise relationship between COPD and comorbidities for each patient is the basis for a correct therapeutic approach.

  3. Air-flow regulation system for a coal gasifier

    DOEpatents

    Fasching, George E.

    1984-01-01

    An improved air-flow regulator for a fixed-bed coal gasifier is provided which allows close air-flow regulation from a compressor source even though the pressure variations are too rapid for a single primary control loop to respond. The improved system includes a primary controller to control a valve in the main (large) air supply line to regulate large slow changes in flow. A secondary controller is used to control a smaller, faster acting valve in a secondary (small) air supply line parallel to the main line valve to regulate rapid cyclic deviations in air flow. A low-pass filter with a time constant of from 20 to 50 seconds couples the output of the secondary controller to the input of the primary controller so that the primary controller only responds to slow changes in the air-flow rate, the faster, cyclic deviations in flow rate sensed and corrected by the secondary controller loop do not reach the primary controller due to the high frequency rejection provided by the filter. This control arrangement provides at least a factor of 5 improvement in air-flow regulation for a coal gasifier in which air is supplied by a reciprocating compressor through a surge tank.

  4. Airflow Measurement of the Car HVAC Unit Using Hot-wire Anemometry

    NASA Astrophysics Data System (ADS)

    Fojtlín, Miloš; Planka, Michal; Fišer, Jan; Pokorný, Jan; Jícha, Miroslav

    2016-03-01

    Thermal environment in a vehicular cabin significantly influence drivers' fatigue and passengers' thermal comfort. This environment is traditionally managed by HVAC cabin system that distributes air and modifies its properties. In order to simulate cabin thermal behaviour, amount of the air led through car vents must be determined. The aim of this study was to develop methodology to measure airflow from the vents, and consequently calculate corresponding air distribution coefficients. Three climatic cases were selected to match European winter, summer, and spring / fall conditions. Experiments were conducted on a test vehicle in a climatic chamber. The car HVAC system was set to automatic control mode, and the measurements were executed after the system stabilisation—each case was independently measured three times. To be able to evaluate precision of the method, the airflow was determined at the system inlet (HVAC suction) and outlet (each vent), and the total airflow values were compared. The airflow was calculated by determining a mean value of the air velocity multiplied by an area of inlet / outlet cross-section. Hot-wire anemometry was involved to measure the air velocity. Regarding the summer case, total airflow entering the cabin was around 57 l s-1 with 60 % of the air entering the cabin through dashboard vents; no air was supplied to the feet compartment. The remaining cases had the same total airflow of around 42 l s-1, and the air distribution was focused mainly on feet and windows. The inlet and outlet airflow values show a good match with a maximum mass differential of 8.3 %.

  5. Implementing clinical guidelines for chronic obstructive pulmonary disease: barriers and solutions

    PubMed Central

    Overington, Jeff D.; Huang, Yao C.; Abramson, Michael J.; Brown, Juliet L.; Goddard, John R.; Bowman, Rayleen V.; Fong, Kwun M.

    2014-01-01

    Chronic obstructive pulmonary disease (COPD) is a complex chronic lung disease characterised by progressive fixed airflow limitation and acute exacerbations that frequently require hospitalisation. Evidence-based clinical guidelines for the diagnosis and management of COPD are now widely available. However, the uptake of these COPD guidelines in clinical practice is highly variable, as is the case for many other chronic disease guidelines. Studies have identified many barriers to implementation of COPD and other guidelines, including factors such as lack of familiarity with guidelines amongst clinicians and inadequate implementation programs. Several methods for enhancing adherence to clinical practice guidelines have been evaluated, including distribution methods, professional education sessions, electronic health records (EHR), point of care reminders and computer decision support systems (CDSS). Results of these studies are mixed to date, and the most effective ways to implement clinical practice guidelines remain unclear. Given the significant resources dedicated to evidence-based medicine, effective dissemination and implementation of best practice at the patient level is an important final step in the process of guideline development. Future efforts should focus on identifying optimal methods for translating the evidence into everyday clinical practice to ensure that patients receive the best care. PMID:25478199

  6. Use of helium-oxygen mixture in adult patients presenting with exacerbations of asthma and chronic obstructive pulmonary disease: a systematic review.

    PubMed

    Colebourn, C L; Barber, V; Young, J D

    2007-01-01

    We examined systematically all controlled and cross-over randomised trials in patients with acute exacerbations of asthma and chronic obstructive pulmonary disease comparing Heliox against air-oxygen mixtures. Fourteen studies were identified. In asthma studies, peak expiratory flow rate (PEFR) was increased by an average of 29.6% (95% CI 16.6-42.6) by Heliox-driven nebulisers, or by 13.3 l.min(-1) (95% CI 3.71-22.81) absolute. In studies of patients with chronic obstructive pulmonary disease receiving non-invasive ventilation the arterial carbon dioxide tension (P(a)co(2)) and respiratory rate were unchanged: weighted mean difference for P(a)co(2)-0.29kPa (95% CI - 0.64-0.07) favoured Heliox, and for respiratory rate 1.6 breaths.min(-1) (95% CI - 0.93, 4.14) favoured control. Heliox minimally reduced the work of breathing in intubated patients, and reduced intrinsic positive end expiratory pressure (iPEEP). The use of Heliox to drive nebulisers in patients with acute asthma slightly improves airflow measures. We were unable to determine whether this improved recovery.

  7. Design of a new controller to treat the obstructive sleep apnea

    NASA Astrophysics Data System (ADS)

    Netzel, Thomas

    2002-06-01

    The obstructive sleep apnoea (OSA) is a sleep related breathing disorder caused by a relaxation of the upper airway structure during the sleep that leads to a complete closure of the upper airway. The most successful therapy is the nasal continuous positive airway pressure (nCPAP) treatment that keeps the airway opened. More recent devices use an automatic adaptation of the applied pressure. Either the forced oscillation technique (FOT) or the evaluation of the inspiration flow contour are used to evaluate the severity of obstructions. Both methods have disadvantages that may lead to wrong applied pressures. Based on the precise measurement of airflow and mask pressure during nCPAP with a Weinmann SOMNOsmart and additional polysomnography a new parameter set is presented that uses the advantage of both methods to detect the obstructive sleep apnoea. To evaluate the applicability of this parameter set to control Auto-nCPAP-devices a fuzzy-controller is designed under MATLAB/Simulink using an A/D-D/A-converter to control the blower of the SOMNOsmart during Auto-nCPAP-therapy. Obstructive events are detected and treated with a rise of nCPAP-pressure depending on the inspiratory flow requirement. The pressure is lowered after the end of flow limited phases. Although temporary low pressures no oxygen desaturation is recognized by the pulse oxymeter.

  8. Airflow obstruction among street vendors who refill cigarette lighters with liquefied petroleum gas.

    PubMed

    Moitra, S; Blanc, P D; Brashier, B B

    2014-09-01

    Manual cigarette lighter refilling with butane/propane admixed liquefied petroleum gas (LPG) is a common low-income occupation in India. This practice may cause adverse health effects from LPG exposure among such workers. To assess respiratory status among LPG-exposed workers and non-exposed controls. We quantified the exposure and evaluated respiratory symptoms and lung function among 113 LPG refilling workers (aged 41.9±9.9 years) and 79 controls (aged 40.8±7.2 years). We used multiple linear regression analysis to estimate the LPG exposure response within the group of refilling workers, adjusting for age, height and smoking status. Compared to the controls, the LPG-exposed lighter refillers manifested a 190 ml decrement in 1-second forced expiratory volume (FEV1) (2.55±0.4 vs. 2.26±0.3 l) and a 6% decrement in FEV1/forced vital capacity (FVC) (both P < 0.05). We found a significantly negative exposure response among the LPG workers: for FVC and FEV1, 44 ml per ml of reported daily LPG use in refilling (P < 0.05). Likely heavy exposure to LPG through manually refilling cigarette lighters is associated with airflow decrements. This adverse effect may be relevant to other occupational groups heavily exposed to volatile hydrocarbons, especially those in marginal employment sectors.

  9. Voluntary Cough Airflow Differentiates Safe versus Unsafe Swallowing in Amyotrophic Lateral Sclerosis

    PubMed Central

    Plowman, Emily K.; Watts, Stephanie A.; Robison, Raele; Tabor, Lauren; Dion, Charles; Gaziano, Joy; Vu, Tuan; Gooch, Clifton

    2016-01-01

    Dysphagia and aspiration are prevalent in amyotrophic lateral sclerosis (ALS) and contribute to malnutrition, aspiration pneumonia and death. Early detection of at risk individuals is critical to ensure maintenance of safe oral intake and optimal pulmonary function. We therefore aimed to determine the discriminant ability of voluntary cough airflow measures in detecting penetration/aspiration status in ALS patients. Seventy individuals with ALS (El-Escorial criteria) completed voluntary cough spirometry testing and underwent a standardized videofluoroscopic swallowing evaluation (VFSE). A rater blinded to aspiration status derived six objective measures of voluntary cough airflow and evaluated airway safety using the Penetration Aspiration Scale (PAS). A between groups ANOVA (safe vs. unsafe swallowers) was conducted and sensitivity, specificity, area under the curve (AUC) and likelihood ratios were calculated. VFSE analysis revealed 24 penetrator/aspirators (PAS ≥3) and 46 non-penetrator/aspirators (PAS ≤2). Cough volume acceleration (CVA), peak expiratory flow rise time (PEFRT), and peak expiratory flow rate (PEFR) were significantly different between airway safety groups (p <0.05) and demonstrated significant discriminant ability to detect the presence of penetration/aspiration with AUC values of: 0.85, 0.81, and 0.78 respectively. CVA < 45.28L/s/s, PEFR <3.97L/s, and PEFRT > 76ms had sensitivities of 91.3%, 82.6% and 73.9% respectively and specificities of 82.2%, 73.9%, and 78.3% for identifying ALS penetrator/aspirators. Voluntary cough airflow measures identified ALS patients at risk for penetration/aspiration and may be a valuable screening tool with high clinical utility. PMID:26803772

  10. Chronic Obstructive Pulmonary Disease: From Injury to Genomic Stability.

    PubMed

    Sergio, Luiz Philippe da Silva; de Paoli, Flavia; Mencalha, Andre Luiz; da Fonseca, Adenilson de Souza

    2017-08-01

    Chronic obstructive pulmonary disease (COPD) is the fourth cause of death in the world and it is currently presenting a major global public health challenge, causing premature death from pathophysiological complications and rising economic and social burdens. COPD develops from a combination of factors following exposure to pollutants and cigarette smoke, presenting a combination of both emphysema and chronic obstructive bronchitis, which causes lung airflow limitations that are not fully reversible by bronchodilators. Oxidative stress plays a key role in the maintenance and amplification of inflammation in tissue injury, and also induces DNA damages. Once the DNA molecule is damaged, enzymatic mechanisms act in order to repair the DNA molecule. These mechanisms are specific to repair of oxidative damages, such as nitrogen base modifications, or larger DNA damages, such as double-strand breaks. In addition, there is an enzymatic mechanism for the control of telomere length. All these mechanisms contribute to cell viability and homeostasis. Thus, therapies based on modulation of DNA repair and genomic stability could be effective in improving repair and recovery of lung tissue in patients with COPD.

  11. MICROPROCESSOR CONTROL OF ROTOGRAVURE AIRFLOWS

    EPA Science Inventory

    The report discusses the technical and economic viability of using micro-processor-based control technology to collect volatile organic compound (VOC) emissions from a paper coating operation. The microprocessor-based control system monitors and controls both the airflow rate and...

  12. The Measurement of Airflow Using Singing Helmet That Allows Free Movement of the Jaw.

    PubMed

    Jiang, Jack J; Hanna, Rewais B; Willey, Malachi V; Rieves, Adam

    2016-11-01

    Airflow measurement is a useful method of evaluating laryngeal physiology. We introduce a noninvasive device that measures airflow without restricting jaw movement or requiring phonation into a mouthpiece, thus facilitating measurement during singing and connected speech. Validation and human subject trials were conducted. Airflow measurements were obtained from 16 male and 16 female subjects during singing, speech, and constant vowel production tasks. A similar helmet was designed by Stevens and Mead in 1968. The new device validity was evaluated by comparing the measured volume of air to a known volume of administered air using a calibration syringe. Subjects were asked to voice sustained vowels at low, medium, and high vocal intensity, read two sentences at a conversational volume, and perform different singing exercises while airflow was recorded. The device accurately and reliably measured airflow with mean airflow values falling within previously published ranges. There was an experimentally determined response time of 0.173 ± 0.014 seconds. Subjects were able to comfortably perform speech and singing exercises. Male subjects had higher airflow for all sustained vowels (P < 0.05). Airflow was higher for abduction rather than adduction sentences (P < 0.05). No other portable device has been shown to measure airflow during singing and speech while allowing for free movement of the jaw. This device provides a more natural environment to measure airflow that could be used to help evaluate laryngeal function and aid in singing training. Copyright © 2016 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  13. Genome-Wide Association Analysis of Body Mass in Chronic Obstructive Pulmonary Disease

    PubMed Central

    Wan, Emily S.; Cho, Michael H.; Boutaoui, Nadia; Klanderman, Barbara J.; Sylvia, Jody S.; Ziniti, John P.; Won, Sungho; Lange, Christoph; Pillai, Sreekumar G.; Anderson, Wayne H.; Kong, Xiangyang; Lomas, David A.; Bakke, Per S.; Gulsvik, Amund; Regan, Elizabeth A.; Murphy, James R.; Make, Barry J.; Crapo, James D.; Wouters, Emiel F.; Celli, Bartolome R.; Silverman, Edwin K.; DeMeo, Dawn L.

    2011-01-01

    Cachexia, whether assessed by body mass index (BMI) or fat-free mass index (FFMI), affects a significant proportion of patients with chronic obstructive pulmonary disease (COPD), and is an independent risk factor for increased mortality, increased emphysema, and more severe airflow obstruction. The variable development of cachexia among patients with COPD suggests a role for genetic susceptibility. The objective of the present study was to determine genetic susceptibility loci involved in the development of low BMI and FFMI in subjects with COPD. A genome-wide association study (GWAS) of BMI was conducted in three independent cohorts of European descent with Global Initiative for Chronic Obstructive Lung Disease stage II or higher COPD: Evaluation of COPD Longitudinally to Identify Predictive Surrogate End-Points (ECLIPSE; n = 1,734); Norway-Bergen cohort (n = 851); and a subset of subjects from the National Emphysema Treatment Trial (NETT; n = 365). A genome-wide association of FFMI was conducted in two of the cohorts (ECLIPSE and Norway). In the combined analyses, a significant association was found between rs8050136, located in the first intron of the fat mass and obesity–associated (FTO) gene, and BMI (P = 4.97 × 10−7) and FFMI (P = 1.19 × 10−7). We replicated the association in a fourth, independent cohort consisting of 502 subjects with COPD from COPDGene (P = 6 × 10−3). Within the largest contributing cohort of our analysis, lung function, as assessed by forced expiratory volume at 1 second, varied significantly by FTO genotype. Our analysis suggests a potential role for the FTO locus in the determination of anthropomorphic measures associated with COPD. PMID:21037115

  14. Airflow accelerates bovine and human articular cartilage drying and chondrocyte death.

    PubMed

    Paterson, S I; Amin, A K; Hall, A C

    2015-02-01

    Exposure of articular cartilage to static air results in changes to the extracellular matrix (ECM) and stimulates chondrocyte death, which may cause joint degeneration. However during open orthopaedic surgery, cartilage is often exposed to laminar airflow, which may exacerbate these damaging effects. We compared drying in static and moving air in terms of cartilage appearance, hydration and chondrocyte viability, and tested the ability of saline-saturated gauze to limit the detrimental effects of air exposure. Articular cartilage from bovine metatarsophalangeal joints (N = 50) and human femoral heads (N = 6) was exposed for 90 min to (1) static air (2) airflow (up to 0.34 m/s), or (3) airflow (0.18 m/s), covered with gauze. Following air exposure, cartilage was also rehydrated (0.9% saline; 120 min) to determine the reversibility of drying effects. The influence of airflow was assessed by studying macroscopic appearance, and quantifying superficial zone (SZ) chondrocyte viability and cartilage hydration. Airflow caused advanced changes to cartilage appearance, accelerated chondrocyte death, and increased dehydration compared to static air. These effects were prevented if cartilage was covered by saline-saturated gauze. Cartilage rehydration reversed macroscopic changes associated with drying but the chondrocyte death was not altered. Chondrocytes at the cut edge of cartilage were more sensitive to drying compared to cells distant from the edge. Airflow significantly increased articular cartilage dehydration and chondrocyte death compared to static air. As laminar airflow is routinely utilised in operating theatres, it is essential that articular cartilage is kept wet via irrigation or by covering with saline-saturated gauze to prevent chondrocyte death. Copyright © 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  15. Airflow energy harvesting with high wind velocities for industrial applications

    NASA Astrophysics Data System (ADS)

    Chew, Z. J.; Tuddenham, S. B.; Zhu, M.

    2016-11-01

    An airflow energy harvester capable of harvesting energy from vortices at high speed is presented in this paper. The airflow energy harvester is implemented using a modified helical Savonius turbine and an electromagnetic generator. A power management module with maximum power point finding capability is used to manage the harvested energy and convert the low voltage magnitude from the generator to a usable level for wireless sensors. The airflow energy harvester is characterized using vortex generated by air hitting a plate in a wind tunnel. By using an aircraft environment with wind speed of 17 m/s as case study, the output power of the airflow energy harvester is measured to be 126 mW. The overall efficiency of the power management module is 45.76 to 61.2%, with maximum power point tracking efficiency of 94.21 to 99.72% for wind speed of 10 to 18 m/s, and has a quiescent current of 790 nA for the maximum power point tracking circuit.

  16. Investigation of airflow effects on the dielectric barrier discharge with single/double discharge channel arrangement

    NASA Astrophysics Data System (ADS)

    Fan, Zhihui; Yan, Huijie; Liu, Yidi; Guo, Hongfei; Wang, Yuying; Ren, Chunsheng

    2018-05-01

    Atmospheric-pressure dielectric barrier discharge (DBD) with airflow participation has been widely used in recent years. In this paper, effects of airflow on DBD characteristics are experimentally investigated by single/double pin-to-plate DBD arrangements with an AC exciting source. The discharge electrical characteristics and the movements of discharge channels in airflow are investigated with a single pin electrode arrangement. The current intensities increase in positive cycles and decrease in negative cycles with the increase in airflow velocity. The transition from a filamentary discharge to a diffuse discharge is observed under certain airflow conditions, and the discharge channels move with the airflow with a movement velocity less than the corresponding airflow velocity. In the cases of double pin electrode arrangements, the repulsion between double pin discharge channels is apparent at a 10 mm distance but is not obvious at a 20 mm distance. When the airflow is introduced into the discharge gap, not as in the case of single pin electrode arrangement, the movements of discharge channels in airflow are affected by adjacent discharge channels. The corresponding reasons are analyzed in the paper.

  17. Airflow, gas deposition, and lesion distribution in the nasal passages.

    PubMed Central

    Morgan, K T; Monticello, T M

    1990-01-01

    The nasal passages of laboratory animals and man are complex, and lesions induced in the delicate nasal lining by inhaled air pollutants vary considerably in location and nature. The distribution of nasal lesions is generally a consequence of regional deposition of the inhaled material, local tissue susceptibility, or a combination of these factors. Nasal uptake and regional deposition are are influenced by numerous factors including the physical and chemical properties of the inhaled material, such as water solubility and reactivity; airborne concentration and length of exposure; the presence of other air contaminants such as particulate matter; nasal metabolism, and blood and mucus flow. For certain highly water-soluble or reactive gases, nasal airflow patterns play a major role in determining lesion distribution. Studies of nasal airflow in rats and monkeys, using casting and molding techniques combined with a water-dye model, indicate that nasal airflow patterns are responsible for characteristic differences in the distribution of nasal lesions induced by formaldehyde in these species. Local tissue susceptibility is also a complex issue that may be a consequence of many factors, including physiologic and metabolic characteristics of the diverse cell populations that comprise each of the major epithelial types lining the airways. Identification of the principal factors that influence the distribution and nature of nasal lesions is important when attempting the difficult process of determining potential human risks using data derived from laboratory animals. Toxicologic pathologists can contribute to this process by carefully identifying the site and nature of nasal lesions induced by inhaled materials. Images FIGURE 4. FIGURE 6. FIGURE 7. PMID:2200663

  18. Updates in the management of stable chronic obstructive pulmonary disease.

    PubMed

    Narsingam, Saiprasad; Bozarth, Andrew L; Abdeljalil, Asem

    2015-01-01

    Chronic obstructive pulmonary disease (COPD) is a preventable and treatable disease state characterized by persistent airflow limitation that is usually progressive and associated with an enhanced chronic inflammatory process. It is increasingly recognized as a major public health problem, affecting more than 20 million adults in the US. It is also recognized as a leading cause of hospitalizations and is the fourth leading cause of death in the US. The Global Initiative for Chronic Obstructive Lung Disease (GOLD) operates to promote evidence-based management of COPD, increase awareness and encourage research. In 2011, GOLD published a consensus report detailing evidence-based management strategies for COPD, which were last updated in 2015. In recent years, newer strategies and a growing number of new pharmacologic agents to treat symptoms of COPD have also been introduced and show promise in improving the management of COPD. We aim to provide an evidence-based review of the available and upcoming pharmacologic and non-pharmacologic treatment options for stable COPD, with continued emphasis on evidence-based management.

  19. Measurement of Turbine Engine Transient Airflow in Ground Test Facilities

    DTIC Science & Technology

    1980-08-01

    REPORT NUMBER 12 GOVT ACCESSION NO. A E D C - T R - 8 0 - 2 1 L 6. T I T L E (aqd Subl l l |e ) MEASUREMENT OF TURBINE ENGINE TRANSIENT AIRFLOW IN...21 ILLUSTRATIONS Figure !. Direct-Connect Turbine Engine Test Cell Installation...26 3. Turbine Engine Transient Airflow Simulator (TETAS) . . . . . . . . . . . . . . . . . . . . . . . . . 27 4

  20. Estimating Engine Airflow in Gas-Turbine Powered Aircraft with Clean and Distorted Inlet Flows

    NASA Technical Reports Server (NTRS)

    Williams, J. G.; Steenken, W. G.; Yuhas, A. J.

    1996-01-01

    The P404-GF-400 Powered F/A-18A High Alpha Research Vehicle (HARV) was used to examine the impact of inlet-generated total-pressure distortion on estimating levels of engine airflow. Five airflow estimation methods were studied. The Reference Method was a fan corrected airflow to fan corrected speed calibration from an uninstalled engine test. In-flight airflow estimation methods utilized the average, or individual, inlet duct static- to total-pressure ratios, and the average fan-discharge static-pressure to average inlet total-pressure ratio. Correlations were established at low distortion conditions for each method relative to the Reference Method. A range of distorted inlet flow conditions were obtained from -10 deg. to +60 deg. angle of attack and -7 deg. to +11 deg. angle of sideslip. The individual inlet duct pressure ratio correlation resulted in a 2.3 percent airflow spread for all distorted flow levels with a bias error of -0.7 percent. The fan discharge pressure ratio correlation gave results with a 0.6 percent airflow spread with essentially no systematic error. Inlet-generated total-pressure distortion and turbulence had no significant impact on the P404-GE400 engine airflow pumping. Therefore, a speed-flow relationship may provide the best airflow estimate for a specific engine under all flight conditions.

  1. Computer simulation of airflow through a multi-generation tracheobronchial conducting airway

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fan, B.; Cheng, Yung-Sung; Yeh, Hsu-Chi

    1995-12-01

    Knowledge of airflow patterns in the human lung is important for an analysis of lung diseases and drug delivery of aerosolized medicine for medical treatment. However, very little systematic information is available on the pattern of airflow in the lung and on how this pattern affects the deposition of toxicants in the lung, and the efficacy of aerosol drug therapy. Most previous studies have only considered the airflow through a single bifurcating airway. However, the flow in a network of more than one bifurcation is more complicated due to the effect of interrelated lung generations. Because of the variation ofmore » airway geometry and flow condition from generation to generation, a single bifurcating airway cannot be taken as a representative for the others in different generations. The flow in the network varies significantly with airway generations because of a redistribution of axial momentum by the secondary flow motions. The influence of the redistribution of flow is expected in every generation. Therefore, a systematic information of the airflow through a multi-generation tracheobronchial conducting airway is needed, and it becomes the purpose of this study. This study has provided information on airflow in a lung model which is necessary to the study of the deposition of toxicants and therapeutic aerosols.« less

  2. Chronic intestinal pseudo-obstruction.

    PubMed

    Gabbard, Scott L; Lacy, Brian E

    2013-06-01

    Chronic intestinal pseudo-obstruction (CIP) is a rare and serious disorder of the gastrointestinal (GI) tract characterized as a motility disorder with the primary defect of impaired peristalsis; symptoms are consistent with a bowel obstruction, although mechanical obstruction cannot be identified. CIP is classified as a neuropathy, myopathy, or mesenchymopathy; it is a neuropathic process in the majority of patients. The natural history of CIP is generally that of a progressive disorder, although occasional patients with secondary CIP note significant symptomatic improvement when the underlying disorder is identified and treated. Symptoms vary from patient to patient depending on the location of the luminal GI tract involved and the degree of involvement; however, the small intestine is nearly always involved. Common symptoms include dysphagia, gastroesophageal reflux, abdominal pain, nausea, vomiting, bloating, abdominal distension, constipation or diarrhea, and involuntary weight loss. Unfortunately, these symptoms are nonspecific, which can contribute to misdiagnosis or a delay in diagnosis and treatment. Since many of the symptoms and signs suggest a mechanical bowel obstruction, diagnostic tests typically focus on uncovering a mechanical obstruction, although routine tests do not identify an obstructive process. Nutrition supplementation is required for many patients with CIP due to symptoms of dysphagia, nausea, vomiting, and weight loss. This review discusses the epidemiology, etiology, pathogenesis, diagnosis, and treatment of patients with CIP, with an emphasis on nutrition assessment and treatment options for patients with nutrition compromise.

  3. Chronic Obstructive Pulmonary Disease Exacerbations in the COPDGene Study: Associated Radiologic Phenotypes

    PubMed Central

    Kazerooni, Ella A.; Lynch, David A.; Liu, Lyrica X.; Murray, Susan; Curtis, Jeffrey L.; Criner, Gerard J.; Kim, Victor; Bowler, Russell P.; Hanania, Nicola A.; Anzueto, Antonio R.; Make, Barry J.; Hokanson, John E.; Crapo, James D.; Silverman, Edwin K.; Martinez, Fernando J.; Washko, George R.

    2011-01-01

    Purpose: To test the hypothesis—given the increasing emphasis on quantitative computed tomographic (CT) phenotypes of chronic obstructive pulmonary disease (COPD)—that a relationship exists between COPD exacerbation frequency and quantitative CT measures of emphysema and airway disease. Materials and Methods: This research protocol was approved by the institutional review board of each participating institution, and all participants provided written informed consent. One thousand two subjects who were enrolled in the COPDGene Study and met the GOLD (Global Initiative for Chronic Obstructive Lung Disease) criteria for COPD with quantitative CT analysis were included. Total lung emphysema percentage was measured by using the attenuation mask technique with a −950-HU threshold. An automated program measured the mean wall thickness and mean wall area percentage in six segmental bronchi. The frequency of COPD exacerbation in the prior year was determined by using a questionnaire. Statistical analysis was performed to examine the relationship of exacerbation frequency with lung function and quantitative CT measurements. Results: In a multivariate analysis adjusted for lung function, bronchial wall thickness and total lung emphysema percentage were associated with COPD exacerbation frequency. Each 1-mm increase in bronchial wall thickness was associated with a 1.84-fold increase in annual exacerbation rate (P = .004). For patients with 35% or greater total emphysema, each 5% increase in emphysema was associated with a 1.18-fold increase in this rate (P = .047). Conclusion: Greater lung emphysema and airway wall thickness were associated with COPD exacerbations, independent of the severity of airflow obstruction. Quantitative CT can help identify subgroups of patients with COPD who experience exacerbations for targeted research and therapy development for individual phenotypes. © RSNA, 2011 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10

  4. Comorbidity in chronic obstructive pulmonary disease. Related to disease severity?

    PubMed

    Echave-Sustaeta, Jose M; Comeche Casanova, Lorena; Cosio, Borja G; Soler-Cataluña, Juan Jose; Garcia-Lujan, Ricardo; Ribera, Xavier

    2014-01-01

    Several diseases commonly co-exist with chronic obstructive pulmonary disease (COPD), especially in elderly patients. This study aimed to investigate whether there is an association between COPD severity and the frequency of comorbidities in stable COPD patients. In this multicenter, cross-sectional study, patients with spirometric diagnosis of COPD attended to by internal medicine departments throughout Spain were consecutively recruited by 225 internal medicine specialists. The severity of airflow obstruction was graded using the Global Initiative for Chronic Obstructive Lung Disease (GOLD) and data on demographics, smoking history, comorbidities, and dyspnea were collected. The Charlson comorbidity score was calculated. Eight hundred and sixty-six patients were analyzed: male 93%, mean age 69.8 (standard deviation [SD] 9.7) years and forced vital capacity in 1 second 42.1 (SD 17.7)%. Even, the mean (SD) Charlson score was 2.2 (2.2) for stage I, 2.3 (1.5) for stage II, 2.5 (1.6) for stage III, and 2.7 (1.8) for stage IV (P=0.013 between stage I and IV groups), independent predictors of Charlson score in the multivariate analysis were age, smoking history (pack-years), the hemoglobin level, and dyspnea, but not GOLD stage. COPD patients attended to in internal medicine departments show high scores of comorbidity. However, GOLD stage was not an independent predictor of comorbidity.

  5. COPD-X Australian and New Zealand guidelines for the diagnosis and management of chronic obstructive pulmonary disease: 2017 update.

    PubMed

    Yang, Ian A; Brown, Juliet L; George, Johnson; Jenkins, Sue; McDonald, Christine F; McDonald, Vanessa M; Phillips, Kirsten; Smith, Brian J; Zwar, Nicholas A; Dabscheck, Eli

    2017-11-20

    Chronic obstructive pulmonary disease (COPD) is characterised by persistent respiratory symptoms and chronic airflow limitation, and is associated with exacerbations and comorbidities. Advances in the management of COPD are updated quarterly in the national COPD guidelines, the COPD-X plan, published by Lung Foundation Australia in conjunction with the Thoracic Society of Australia and New Zealand and available at http://copdx.org.au. Main recommendations: Spirometry detects persistent airflow limitation (post-bronchodilator FEV1/FVC < 0.7) and must be used to confirm the diagnosis.Non-pharmacological and pharmacological therapies should be considered as they optimise function (ie, improve symptoms and quality of life) and prevent deterioration (ie, prevent exacerbations and reduce decline).Pulmonary rehabilitation and regular exercise are highly beneficial and should be provided to all symptomatic COPD patients.Short- and long-acting inhaled bronchodilators and, in more severe disease, anti-inflammatory agents (inhaled corticosteroids) should be considered in a stepwise approach.Given the wide range of inhaler devices available, inhaler technique and adherence should be checked regularly.Smoking cessation is essential, and influenza and pneumococcal vaccinations reduce the risk of exacerbations.A plan of care should be developed with the multidisciplinary team. COPD action plans reduce hospitalisations and are recommended as part of COPD self-management.Exacerbations should be managed promptly with bronchodilators, corticosteroids and antibiotics as appropriate to prevent hospital admission and delay COPD progression.Comorbidities of COPD require identification and appropriate management.Supportive, palliative and end-of-life care are beneficial for patients with advanced disease.Education of patients, carers and clinicians, and a strong partnership between primary and tertiary care, facilitate evidence-based management of COPD. Changes in management as result of

  6. Experimental Research on Optimizing Inlet Airflow of Wet Cooling Towers under Crosswind Conditions

    NASA Astrophysics Data System (ADS)

    Chen, You Liang; Shi, Yong Feng; Hao, Jian Gang; Chang, Hao; Sun, Feng Zhong

    2018-01-01

    A new approach of installing air deflectors around tower inlet circumferentially was proposed to optimize the inlet airflow and reduce the adverse effect of crosswinds on the thermal performance of natural draft wet cooling towers (NDWCT). And inlet airflow uniformity coefficient was defined to analyze the uniformity of circumferential inlet airflow quantitatively. Then the effect of air deflectors on the NDWCT performance was investigated experimentally. By contrast between inlet air flow rate and cooling efficiency, it has been found that crosswinds not only decrease the inlet air flow rate, but also reduce the uniformity of inlet airflow, which reduce NDWCT performance jointly. After installing air deflectors, the inlet air flow rate and uniformity coefficient increase, the uniformity of heat and mass transfer increases correspondingly, which improve the cooling performance. In addition, analysis on Lewis factor demonstrates that the inlet airflow optimization has more enhancement of heat transfer than mass transfer, but leads to more water evaporation loss.

  7. Surgery for adult patients with obstructive sleep apnoea: A review for general practitioners.

    PubMed

    Phan, Nga T; Wallwork, Benjamin; Panizza, Benedict

    2016-08-01

    Obstructive sleep apnoea (OSA) is a complex disease process that involves collapse of the upper airway during sleep and subsequent reduction or cessation of airflow. Continuous positive airway pressure (CPAP) is the primary treatment for OSA and is the recommended first-line treatment for patients with moderate-to-severe forms of the disease. However, some patients are unable to tolerate CPAP or are unwilling to accept it as a form of permanent management. In these cases, surgical management aimed at addressing anatomical obstruction may be useful and warranted. This article presents an overview of the surgical options available for OSA. The review also describes a useful approach for selecting appropriate patients for surgery. On the basis of an OSA model that accounts for observed increased risk of stroke, cardiovascular disease and motor vehicle accidents, there is evidence to support that surgery is beneficial and cost-effective for patients with severe OSA who are intolerant of CPAP. There are many surgical options available for OSA.

  8. Volumetric evaluation of pharyngeal segments in obstructive sleep apnea patients.

    PubMed

    Rodrigues, Marcos Marques; Pereira Filho, Valfrido Antonio; Gabrielli, Mário Francisco Real; Oliveira, Talles Fernando Medeiros de; Batatinha, Júlio Américo Pereira; Passeri, Luis Augusto

    2017-01-30

    Obstructive sleep apnea occurs by recurrent collapse of the upper airway during sleep, resulting in total (apnea) or partial (hypopnea) reduction of the airflow and has intimate relation with changes in the upper airway. Cone Beam CT allows the analysis of the upper airway and its volume by three-dimensional reconstruction. To evaluate a possible correlation between the volume of the upper airway and the severity of the obstructive sleep apnea. A retrospective study was performed reviewing polysomnographic data and Cone Beam CT records of 29 patients (13 males and 16 females). The correlation between the volume of the nasopharynx, the oropharynx and the total superior pharynx with the AHI was assessed by Pearson's rank correlation coefficient. The obstructive sleep apnea severity division was: ten patients had severe, 7 had moderate, 6 had mild and 6 of them were healthy. The correlation between the nasopharynx, the oropharynx and the total superior pharynx volumes and the Apnea-Hypopnea-Index was respectively: -0.415 (p=0.025), 0.186 (p=0.334) and -0329 (p=0.089). The Spearman's rank controlled by the Body Mass Index, the age and the gender was: -0.206 (p=0.304), -0.155 (p=0.439) and 0.242 (p=0.284). There is no correlation between the volume of the airway and the obstructive sleep apnea, assessed by Apnea-Hypopnea-Index and controlled by the Body Mass Index, the age and the gender. The volume of the upper airways as an isolated parameter did not correlate to the severity of the obstructive sleep apnea syndrome, and should be evaluated together with other factors. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  9. Measured Performance of a Varied Airflow Small-Diameter Duct System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poerschke, Andrew

    2017-03-01

    This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measuremore » of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.« less

  10. Measured Performance of a Varied Airflow Small-Diameter Duct System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poerschke, Andrew

    This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measuremore » of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.« less

  11. Measurement of the resistivity of porous materials with an alternating air-flow method.

    PubMed

    Dragonetti, Raffaele; Ianniello, Carmine; Romano, Rosario A

    2011-02-01

    Air-flow resistivity is a main parameter governing the acoustic behavior of porous materials for sound absorption. The international standard ISO 9053 specifies two different methods to measure the air-flow resistivity, namely a steady-state air-flow method and an alternating air-flow method. The latter is realized by the measurement of the sound pressure at 2 Hz in a small rigid volume closed partially by the test sample. This cavity is excited with a known volume-velocity sound source implemented often with a motor-driven piston oscillating with prescribed area and displacement magnitude. Measurements at 2 Hz require special instrumentation and care. The authors suggest an alternating air-flow method based on the ratio of sound pressures measured at frequencies higher than 2 Hz inside two cavities coupled through a conventional loudspeaker. The basic method showed that the imaginary part of the sound pressure ratio is useful for the evaluation of the air-flow resistance. Criteria are discussed about the choice of a frequency range suitable to perform simplified calculations with respect to the basic method. These criteria depend on the sample thickness, its nonacoustic parameters, and the measurement apparatus as well. The proposed measurement method was tested successfully with various types of acoustic materials.

  12. Quality Improvement Initiatives to Optimize the Management of Chronic Obstructive Pulmonary Disease in Patients With Lung Cancer.

    PubMed

    Digby, Geneviève C; Robinson, Andrew

    2017-11-01

    Patients with lung cancer (LC) frequently have chronic obstructive pulmonary disease (COPD), the optimization of which improves outcomes. A 2014 Queen's University Hospitals audit demonstrated that COPD was underdiagnosed and undertreated in outpatients with LC. We sought to improve the diagnosis and management of COPD in this population. We implemented change using a Define/Measure/Analyze/Improve/Control (DMAIC) improvement cycle. Data were obtained by chart review from the Cancer Care Ontario database and e-Patient System for patients with newly diagnosed LC, including patient characteristics, pulmonary function test (PFT) data, and bronchodilator therapies. Improvement cycle 1 included engaging stakeholders and prioritizing COPD management by respirologists in the Lung Diagnostic Assessment Program. Improvement cycle 2 included physician restructuring and developing a standard work protocol. Data were analyzed monthly and presented on statistical process control P-charts, which assessed differences over time. The χ 2 and McNemar tests assessed for significance between independent and dependent groups, respectively. A total of 477 patients were studied (165 patients at baseline, 166 patients in cycle 1, and 127 patients in cycle 2). There was no change in PFT completion over time, although respirology-managed patients were significantly more likely to undergo a PFT than patients who were not managed by respirology (56.7% v 96.1%; P < .00001). The proportion of respirology-managed patients with LC with airflow obstruction receiving inhaled bronchodilator significantly increased (baseline, 46.3%; cycle 1, 51.0%; and cycle 2, 74.3%). By cycle 2, patients with airflow obstruction were more likely to receive a long-acting bronchodilator if managed by respirology (74.3% v 44.8%; P = .0009). COPD is underdiagnosed and undertreated in outpatients with LC. A DMAIC quality improvement strategy emphasizing COPD treatment during LC evaluation in the Lung Diagnostic

  13. Asthma-COPD overlap. Clinical relevance of genomic signatures of type 2 inflammation in chronic obstructive pulmonary disease.

    PubMed

    Christenson, Stephanie A; Steiling, Katrina; van den Berge, Maarten; Hijazi, Kahkeshan; Hiemstra, Pieter S; Postma, Dirkje S; Lenburg, Marc E; Spira, Avrum; Woodruff, Prescott G

    2015-04-01

    Chronic obstructive pulmonary disease (COPD) is a heterogeneous disease and likely includes a subgroup that is biologically comparable to asthma. Studying asthma-associated gene expression changes in COPD could add insight into COPD pathogenesis and reveal biomarkers that predict a favorable response to corticosteroids. To determine whether asthma-associated gene signatures are increased in COPD and associated with asthma-related features. We compared disease-associated airway epithelial gene expression alterations in an asthma cohort (n = 105) and two COPD cohorts (n = 237, 171). The T helper type 2 (Th2) signature (T2S) score, a gene expression metric induced in Th2-high asthma, was evaluated in these COPD cohorts. The T2S score was correlated with asthma-related features and response to corticosteroids in COPD in a randomized, placebo-controlled trial, the Groningen and Leiden Universities study of Corticosteroids in Obstructive Lung Disease (GLUCOLD; n = 89). The 200 genes most differentially expressed in asthma versus healthy control subjects were enriched among genes associated with more severe airflow obstruction in these COPD cohorts (P < 0.001), suggesting significant gene expression overlap. A higher T2S score was associated with decreased lung function (P < 0.001), but not asthma history, in both COPD cohorts. Higher T2S scores correlated with increased airway wall eosinophil counts (P = 0.003), blood eosinophil percentage (P = 0.03), bronchodilator reversibility (P = 0.01), and improvement in hyperinflation after corticosteroid treatment (P = 0.019) in GLUCOLD. These data identify airway gene expression alterations that can co-occur in asthma and COPD. The association of the T2S score with increased severity and "asthma-like" features (including a favorable corticosteroid response) in COPD suggests that Th2 inflammation is important in a COPD subset that cannot be identified by clinical history of asthma.

  14. Separate and combined effects of airflow and rehydration during exercise in the heat.

    PubMed

    Mora-Rodriguez, Ricardo; Del Coso, Juan; Aguado-Jimenez, Roberto; Estevez, Emma

    2007-10-01

    To determine whether airflow is required to obtain the beneficial effects of rehydration (thermoregulatory and cardiovascular) during exercise in dry heat. Ten moderately trained (VO2max = 55 +/- 8 mL.kg(-1).min(-1)) heat acclimated males pedaled for 60 min at 60% VO2max in a hot-dry environment (36 +/- 1 degrees C; 29 +/- 2% relative humidity) on four different occasions: 1) without rehydration or forced airflow (control trial; CON); 2) rehydrating 100% of sweat losses by ingestion of a 6% carbohydrate-electrolyte solution (rehydration trial; REH); 3) receiving airflow at a velocity of 2.55 m.s(-1) (wind trial; WIND); and 4) combining airflow and rehydration (W + R). Without airflow, rehydration alone (REH) did not lower rectal temperature below CON (39.0 +/- 0.1 vs 39.1 +/- 0.1 degrees C at 60 min; respectively). However, with airflow, rehydration reduced final rectal temperature (38.8 +/- 0.1 vs 38.5 +/- 0.1 degrees C; P < 0.05; WIND vs W + R). In the trials with wind (WIND and W + R), skin temperature was reduced by about 0.6 degrees C (P < 0.05), and heart rate drift was prevented. In the trials with rehydration (REH and W + R trials), cardiac output (CO2-rebreathing technique) was maintained higher than CON (16.5 +/- 0.4 and 17.0 +/- 0.7 vs 15.4 +/- 0.4 L.min(-1), respectively; P < 0.05). When exercising in a hot-dry environment, airflow is required for rehydration to improve thermoregulation and cardiovascular function.

  15. Energy Harvesting from Human Motion Using Footstep-Induced Airflow

    NASA Astrophysics Data System (ADS)

    Fu, H.; Xu, R.; Seto, K.; Yeatman, E. M.; Kim, S. G.

    2015-12-01

    This paper presents an unobtrusive in-shoe energy harvester converting foot-strike energy into electricity to power wearable or portable devices. An air-pumped turbine system is developed to address the issues of the limited vertical deformation of shoes and the low frequency of human motion that impede harvesting energy from this source. The air pump is employed to convert the vertical foot-strike motion into airflow. The generated airflow passes through the miniaturized wind turbine whose transduction is realized by an electromagnetic generator. Energy is extracted from the generator with a higher frequency than that of footsteps, boosting the output power of the device. The turbine casing is specifically designed to enable the device to operate continuously with airflow in both directions. A prototype was fabricated and then tested under different situations. A 6 mW peak power output was obtained with a 4.9 Ω load. The achievable power from this design was estimated theoretically for understanding and further improvement.

  16. Efficacy of confrontational counselling for smoking cessation in smokers with previously undiagnosed mild to moderate airflow limitation: study protocol of a randomized controlled trial.

    PubMed

    Kotz, Daniel; Wesseling, Geertjan; Huibers, Marcus J H; van Schayck, Onno C P

    2007-11-15

    The use of spirometry for early detection of chronic obstructive pulmonary disease (COPD) is still an issue of debate, particularly because of a lack of convincing evidence that spirometry has an added positive effect on smoking cessation. We hypothesise that early detection of COPD and confrontation with spirometry for smoking cessation may be effective when applying an approach we have termed "confrontational counselling"; a patient-centred approach which involves specific communication skills and elements of cognitive therapy. An important aspect is to confront the smoker with his/her airflow limitation during the counselling sessions. The primary objective of this study is to test the efficacy of confrontational counselling in comparison to regular health education and promotion for smoking cessation delivered by specialized respiratory nurses in current smokers with previously undiagnosed mild to moderate airflow limitation. The study design is a randomized controlled trial comparing confrontational counselling delivered by a respiratory nurse combined with nortriptyline for smoking cessation (experimental group), health education and promotion delivered by a respiratory nurse combined with nortriptyline for smoking cessation (control group 1), and "care as usual" delivered by the GP (control group 2). Early detection of smokers with mild to moderate airflow limitation is achieved by means of a telephone interview in combination with spirometry. Due to a comparable baseline risk of airflow limitation and motivation to quit smoking, and because of the standardization of number, duration, and scheduling of counselling sessions between the experimental group and control group 1, the study enables to assess the "net" effect of confrontational counselling. The study has been ethically approved and registered. Ethical as well as methodological considerations of the study are discussed in this protocol. A significant and relevant effect of confrontational counselling

  17. Data Visualization of Invisible Airflow Hazards During Helicopter Takeoff and Landing Operations

    NASA Technical Reports Server (NTRS)

    Aragon, Cecilia R.

    2004-01-01

    Many aircraft accidents each year are caused by encounters with unseen airflow hazards near the ground such as vortices, downdrafts, wind shear, microbursts, or other turbulence. While such hazards frequently pose problems to fixed-wing airplanes, they are especially dangerous to helicopters, which often have to operate in confined spaces and under operationally stressful conditions. We are developing flight-deck visualizations of airflow hazards during helicopter takeoff and landing operations, and are evaluating their effectiveness with usability studies. Our hope is.that this work will lead to the production of an airflow hazard detection system for pilots that will save lives.

  18. An updated model of induced airflow in the unsaturated zone

    USGS Publications Warehouse

    Baehr, Arthur L.; Joss, Craig J.

    1995-01-01

    Simulation of induced movement of air in the unsaturated zone provides a method to determine permeability and to design vapor extraction remediation systems. A previously published solution to the airflow equation for the case in which the unsaturated zone is separated from the atmosphere by a layer of lower permeability (such as a clay layer) has been superseded. The new solution simulates airflow through the layer of lower permeability more rigorously by defining the leakage in terms of the upper boundary condition rather than by adding a leakage term to the governing airflow equation. This note presents the derivation of the new solution. Formulas for steady state pressure, specific discharge, and mass flow in the domain are obtained for the new model and for the case in which the unsaturated zone is in direct contact with the atmosphere.

  19. Fault tolerant attitude control for small unmanned aircraft systems equipped with an airflow sensor array.

    PubMed

    Shen, H; Xu, Y; Dickinson, B T

    2014-11-18

    Inspired by sensing strategies observed in birds and bats, a new attitude control concept of directly using real-time pressure and shear stresses has recently been studied. It was shown that with an array of onboard airflow sensors, small unmanned aircraft systems can promptly respond to airflow changes and improve flight performances. In this paper, a mapping function is proposed to compute aerodynamic moments from the real-time pressure and shear data in a practical and computationally tractable formulation. Since many microscale airflow sensors are embedded on the small unmanned aircraft system surface, it is highly possible that certain sensors may fail. Here, an adaptive control system is developed that is robust to sensor failure as well as other numerical mismatches in calculating real-time aerodynamic moments. The advantages of the proposed method are shown in the following simulation cases: (i) feedback pressure and wall shear data from a distributed array of 45 airflow sensors; (ii) 50% failure of the symmetrically distributed airflow sensor array; and (iii) failure of all the airflow sensors on one wing. It is shown that even if 50% of the airflow sensors have failures, the aircraft is still stable and able to track the attitude commands.

  20. Coupling the Multizone Airflow and Contaminant Transport Software CONTAM with EnergyPlus Using Co-Simulation.

    PubMed

    Dols, W Stuart; Emmerich, Steven J; Polidoro, Brian J

    2016-08-01

    Building modelers need simulation tools capable of simultaneously considering building energy use, airflow and indoor air quality (IAQ) to design and evaluate the ability of buildings and their systems to meet today's demanding energy efficiency and IAQ performance requirements. CONTAM is a widely-used multizone building airflow and contaminant transport simulation tool that requires indoor temperatures as input values. EnergyPlus is a prominent whole-building energy simulation program capable of performing heat transfer calculations that require interzone and infiltration airflows as input values. On their own, each tool is limited in its ability to account for thermal processes upon which building airflow may be significantly dependent and vice versa. This paper describes the initial phase of coupling of CONTAM with EnergyPlus to capture the interdependencies between airflow and heat transfer using co-simulation that allows for sharing of data between independently executing simulation tools. The coupling is accomplished based on the Functional Mock-up Interface (FMI) for Co-simulation specification that provides for integration between independently developed tools. A three-zone combined heat transfer/airflow analytical BESTEST case was simulated to verify the co-simulation is functioning as expected, and an investigation of a two-zone, natural ventilation case designed to challenge the coupled thermal/airflow solution methods was performed.

  1. Application of a New Spirometric Reference Equation and Its Impact on the Staging of Korean Chronic Obstructive Pulmonary Disease Patients

    PubMed Central

    Hwang, Yong Il; Kim, Eun Ji; Lee, Chang Youl; Park, Sunghoon; Choi, Jeong Hee; Park, Yong Bum; Jang, Seung Hun; Kim, Cheol Hong; Shin, Tae Rim; Park, Sang Myeon; Kim, Dong-Gyu; Lee, Myung-Goo; Hyun, In-Gyu

    2012-01-01

    Purpose A new spirometric reference equation was recently developed from the first national chronic obstructive pulmonary disease (COPD) survey in Korea. However, Morris' equation has been preferred for evaluating spirometric values instead. The objective of this study was to evaluate changes in severity staging in Korean COPD patients by adopting the newly developed Korean equation. Materials and Methods We evaluated the spirometric data of 441 COPD patients. The presence of airflow limitation was defined as an observed post-bronchodilator forced expiratory volume in one second/forced vital capacity (FEV1/FVC) less than 0.7, and the severity of airflow limitation was assessed according to GOLD stages. Spirometric values were reassessed using the new Korean equation, Morris' equation and other reference equations. Results The severity of airflow limitation was differently graded in 143 (32.4%) patients after application of the new Korean equation when compared with Morris' equation. All 143 patients were reallocated into more severe stages (49 at mild stage, 65 at moderate stage, and 29 at severe stage were changed to moderate, severe and very severe stages, respectively). Stages according to other reference equations were changed in 18.6-49.4% of the patients. Conclusion These results indicate that equations from different ethnic groups do not sufficiently reflect the airflow limitation of Korean COPD patients. The Korean reference equation should be used for Korean COPD patients in order to administer proper treatment. PMID:22318825

  2. [Phenotypic heterogeneity of chronic obstructive pulmonary disease].

    PubMed

    Garcia-Aymerich, Judith; Agustí, Alvar; Barberà, Joan A; Belda, José; Farrero, Eva; Ferrer, Antoni; Ferrer, Jaume; Gáldiz, Juan B; Gea, Joaquim; Gómez, Federico P; Monsó, Eduard; Morera, Josep; Roca, Josep; Sauleda, Jaume; Antó, Josep M

    2009-03-01

    A functional definition of chronic obstructive pulmonary disease (COPD) based on airflow limitation has largely dominated the field. However, a view has emerged that COPD involves a complex array of cellular, organic, functional, and clinical events, with a growing interest in disentangling the phenotypic heterogeneity of COPD. The present review is based on the opinion of the authors, who have extensive research experience in several aspects of COPD. The starting assumption of the review is that current knowledge on the pathophysiology and clinical features of COPD allows us to classify phenotypic information in terms of the following dimensions: respiratory symptoms and health status, acute exacerbations, lung function, structural changes, local and systemic inflammation, and systemic effects. Twenty-six phenotypic traits were identified and assigned to one of the 6 dimensions. For each dimension, a summary is provided of the best evidence on the relationships among phenotypic traits, in particular among those corresponding to different dimensions, and on the relationship between these traits and relevant events in the natural history of COPD. The information has been organized graphically into a phenotypic matrix where each cell representing a pair of phenotypic traits is linked to relevant references. The information provided has the potential to increase our understanding of the heterogeneity of COPD phenotypes and help us plan future studies on aspects that are as yet unexplored.

  3. Lung sound intensity in patients with emphysema and in normal subjects at standardised airflows.

    PubMed Central

    Schreur, H J; Sterk, P J; Vanderschoot, J; van Klink, H C; van Vollenhoven, E; Dijkman, J H

    1992-01-01

    BACKGROUND: A common auscultatory finding in pulmonary emphysema is a reduction of lung sounds. This might be due to a reduction in the generation of sounds due to the accompanying airflow limitation or to poor transmission of sounds due to destruction of parenchyma. Lung sound intensity was investigated in normal and emphysematous subjects in relation to airflow. METHODS: Eight normal men (45-63 years, FEV1 79-126% predicted) and nine men with severe emphysema (50-70 years, FEV1 14-63% predicted) participated in the study. Emphysema was diagnosed according to pulmonary history, results of lung function tests, and radiographic criteria. All subjects underwent phonopneumography during standardised breathing manoeuvres between 0.5 and 2 1 below total lung capacity with inspiratory and expiratory target airflows of 2 and 1 l/s respectively during 50 seconds. The synchronous measurements included airflow at the mouth and lung volume changes, and lung sounds at four locations on the right chest wall. For each microphone airflow dependent power spectra were computed by using fast Fourier transformation. Lung sound intensity was expressed as log power (in dB) at 200 Hz at inspiratory flow rates of 1 and 2 l/s and at an expiratory flow rate of 1 l/s. RESULTS: Lung sound intensity was well repeatable on two separate days, the intraclass correlation coefficient ranging from 0.77 to 0.94 between the four microphones. The intensity was strongly influenced by microphone location and airflow. There was, however, no significant difference in lung sound intensity at any flow rate between the normal and the emphysema group. CONCLUSION: Airflow standardised lung sound intensity does not differ between normal and emphysematous subjects. This suggests that the auscultatory finding of diminished breath sounds during the regular physical examination in patients with emphysema is due predominantly to airflow limitation. Images PMID:1440459

  4. Effects of airflow on body temperatures and sleep stages in a warm humid climate

    NASA Astrophysics Data System (ADS)

    Tsuzuki, Kazuyo; Okamoto-Mizuno, Kazue; Mizuno, Koh; Iwaki, Tatsuya

    2008-03-01

    Airflow is an effective way to increase heat loss—an ongoing process during sleep and wakefulness in daily life. However, it is unclear whether airflow stimulates cutaneous sensation and disturbs sleep or reduces the heat load and facilitates sleep. In this study, 17 male subjects wearing short pyjamas slept on a bed with a cotton blanket under two of the following conditions: (1) air temperature (Ta) 26°C, relative humidity (RH) 50%, and air velocity (V) 0.2 m s-1; (2) Ta 32°C, RH 80%, V 1.7 m s-1; (3) Ta 32°C; RH 80%, V 0.2 m s-1 (hereafter referred to as 26/50, 32/80 with airflow, and 32/80 with still air, respectively). Electroencephalograms, electrooculograms, and mental electromyograms were obtained for all subjects. Rectal (Tre) and skin (Ts) temperatures were recorded continuously during the sleep session, and body-mass was measured before and after the sleep session. No significant differences were observed in the duration of sleep stages between subjects under the 26/50 and 32/80 with airflow conditions; however, the total duration of wakefulness decreased significantly in subjects under the 32/80 with airflow condition compared to that in subjects under the 32/80 with still air condition ( P < 0.05). Tre, Tsk, Ts, and body-mass loss under the 32/80 with airflow condition were significantly higher compared to those under the 26/50 condition, and significantly lower than those under the 32/80 with still air condition ( P < 0.05). An alleviated heat load due to increased airflow was considered to exist between the 32/80 with still air and the 26/50 conditions. Airflow reduces the duration of wakefulness by decreasing Tre, Tsk, Ts, and body-mass loss in a warm humid condition.

  5. Monitoring minimization of grade B environments based on risk assessment using three-dimensional airflow measurements and computer simulation.

    PubMed

    Katayama, Hirohito; Higo, Takashi; Tokunaga, Yuji; Katoh, Shigeo; Hiyama, Yukio; Morikawa, Kaoru

    2008-01-01

    A practical, risk-based monitoring approach using the combined data collected from actual experiments and computer simulations was developed for the qualification of an EU GMP Annex 1 Grade B, ISO Class 7 area. This approach can locate and minimize the representative number of sampling points used for microbial contamination risk assessment. We conducted a case study on an aseptic clean room, newly constructed and specifically designed for the use of a restricted access barrier system (RABS). Hotspots were located using three-dimensional airflow analysis based on a previously published empirical measurement method, the three-dimensional airflow analysis. Local mean age of air (LMAA) values were calculated based on computer simulations. Comparable results were found using actual measurements and simulations, demonstrating the potential usefulness of such tools in estimating contamination risks based on the airflow characteristics of a clean room. Intensive microbial monitoring and particle monitoring at the Grade B environmental qualification stage, as well as three-dimensional airflow analysis, were also conducted to reveal contamination hotspots. We found representative hotspots were located at perforated panels covering the air exhausts where the major piston airflows collect in the Grade B room, as well as at any locations within the room that were identified as having stagnant air. However, we also found that the floor surface air around the exit airway of the RABS EU GMP Annex 1 Grade A, ISO Class 5 area was always remarkably clean, possibly due to the immediate sweep of the piston airflow, which prevents dispersed human microbes from falling in a Stokes-type manner on settling plates placed on the floor around the Grade A exit airway. In addition, this airflow is expected to be clean with a significantly low LMAA. Based on these observed results, we propose a simplified daily monitoring program to monitor microbial contamination in Grade B environments. To

  6. Computational modeling of the obstructive lung diseases asthma and COPD

    PubMed Central

    2014-01-01

    Asthma and chronic obstructive pulmonary disease (COPD) are characterized by airway obstruction and airflow limitation and pose a huge burden to society. These obstructive lung diseases impact the lung physiology across multiple biological scales. Environmental stimuli are introduced via inhalation at the organ scale, and consequently impact upon the tissue, cellular and sub-cellular scale by triggering signaling pathways. These changes are propagated upwards to the organ level again and vice versa. In order to understand the pathophysiology behind these diseases we need to integrate and understand changes occurring across these scales and this is the driving force for multiscale computational modeling. There is an urgent need for improved diagnosis and assessment of obstructive lung diseases. Standard clinical measures are based on global function tests which ignore the highly heterogeneous regional changes that are characteristic of obstructive lung disease pathophysiology. Advances in scanning technology such as hyperpolarized gas MRI has led to new regional measurements of ventilation, perfusion and gas diffusion in the lungs, while new image processing techniques allow these measures to be combined with information from structural imaging such as Computed Tomography (CT). However, it is not yet known how to derive clinical measures for obstructive diseases from this wealth of new data. Computational modeling offers a powerful approach for investigating this relationship between imaging measurements and disease severity, and understanding the effects of different disease subtypes, which is key to developing improved diagnostic methods. Gaining an understanding of a system as complex as the respiratory system is difficult if not impossible via experimental methods alone. Computational models offer a complementary method to unravel the structure-function relationships occurring within a multiscale, multiphysics system such as this. Here we review the current

  7. Wireless Wearable Multisensory Suite and Real-Time Prediction of Obstructive Sleep Apnea Episodes.

    PubMed

    Le, Trung Q; Cheng, Changqing; Sangasoongsong, Akkarapol; Wongdhamma, Woranat; Bukkapatnam, Satish T S

    2013-01-01

    Obstructive sleep apnea (OSA) is a common sleep disorder found in 24% of adult men and 9% of adult women. Although continuous positive airway pressure (CPAP) has emerged as a standard therapy for OSA, a majority of patients are not tolerant to this treatment, largely because of the uncomfortable nasal air delivery during their sleep. Recent advances in wireless communication and advanced ("bigdata") preditive analytics technologies offer radically new point-of-care treatment approaches for OSA episodes with unprecedented comfort and afforadability. We introduce a Dirichlet process-based mixture Gaussian process (DPMG) model to predict the onset of sleep apnea episodes based on analyzing complex cardiorespiratory signals gathered from a custom-designed wireless wearable multisensory suite. Extensive testing with signals from the multisensory suite as well as PhysioNet's OSA database suggests that the accuracy of offline OSA classification is 88%, and accuracy for predicting an OSA episode 1-min ahead is 83% and 3-min ahead is 77%. Such accurate prediction of an impending OSA episode can be used to adaptively adjust CPAP airflow (toward improving the patient's adherence) or the torso posture (e.g., minor chin adjustments to maintain steady levels of the airflow).

  8. Predischarge screening for chronic obstructive pulmonary disease in patients with acute coronary syndrome and smoking history.

    PubMed

    Campo, Gianluca; Pavasini, Rita; Barbetta, Carlo; Maietti, Elisa; Mascetti, Susanna; Biscaglia, Simone; Zaraket, Fatima; Spitaleri, Giosafat; Gallo, Francesco; Tonet, Elisabetta; Papi, Alberto; Ferrari, Roberto; Contoli, Marco

    2016-11-01

    Several studies suggested that chronic obstructive pulmonary disease (COPD) is largely underdiagnosed in patients with acute coronary syndrome (ACS) contributing to further affect clinical outcome. Our aim was to validate a screening procedure to identify, in ACS patients, those with negligible risk of undiagnosed COPD. From December 2014 to August 2015, 169 ACS patients with smoking history underwent screening procedure. Screening procedure combined peak expiratory flow rate (PEFR, defined as positive if <80% of predicted) and respiratory health status questionnaire (RHSQ, defined as positive if >19.5 points). The screening was considered negative if both tests provided negative results, positive if both were positive, uncertain in presence of discrepancy. Spirometry was planned after 2months to identify or not the presence of irreversible airflow obstruction (undiagnosed COPD). The primary endpoint was the negative predictive value of screening for undiagnosed COPD. Overall, 137 (81%) patients received spirometry (final study population). Screening was negative, uncertain and positive in 58 (42%), 46 (34%) and 33 (24%) patients, respectively. We found undiagnosed COPD in 39 (29%) patients. Only 3 patients with negative screening showed undiagnosed COPD. Negative screening showed the best ability to discriminate patients without COPD (negative predictive value 95%). Two-month health status in patients with undiagnosed COPD was significantly poor. Undiagnosed COPD is relatively frequent in ACS patients with smoking history and a simple screening procedure including PEFR and RHSQ can be administered before hospital discharge to discriminate those at negligible risk of undiagnosed COPD (ClinicalTrials.gov, NCT02324660). Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. What is normal nasal airflow? A computational study of 22 healthy adults

    PubMed Central

    Zhao, Kai; Jiang, Jianbo

    2014-01-01

    Objective Nasal airflow is essential for functioning of the human nose. Given individual variation in nasal anatomy, there is yet no consensus what constitutes normal nasal airflow patterns. We attempt to obtain such information that is essential to differentiate disease-related variations. Methods Computational fluid dynamics (CFD) simulated nasal airflow in 22 healthy subjects during resting breathing. Streamline patterns, airflow distributions, velocity profiles, pressure, wall stress, turbulence, and vortical flow characteristics under quasi-steady state were analyzed. Patency ratings, acoustically measured minimum cross-sectional area (MCA), and rhinomanometric nasal resistance (NR) were examined for potential correlations with morphological and airflow-related variables. Results Common features across subjects included: >50% total pressure-drop reached near the inferior turbinate head; wall shear stress, NR, turbulence energy, and vorticity were lower in the turbinate than in the nasal valve region. However, location of the major flow path and coronal velocity distributions varied greatly across individuals. Surprisingly, on average, more flow passed through the middle than the inferior meatus and correlated with better patency ratings (r=-0.65, p<0.01). This middle flow percentage combined with peak post-vestibule nasal heat loss and MCA accounted for >70% of the variance in subjective patency ratings and predicted patency categories with 86% success. Nasal index correlated with forming of the anterior dorsal vortex. Expected for resting breathing, the functional impact for local and total turbulence, vorticity, and helicity was limited. As validation, rhinomanometric NR significantly correlated with CFD simulations (r=0.53, p<0.01). Conclusion Significant variations of nasal airflow found among healthy subjects; Key features may have clinically relevant applications. PMID:24664528

  10. Auscultated forced expiratory time as a clinical and epidemiologic test of airway obstruction.

    PubMed

    Kern, D G; Patel, S R

    1991-09-01

    Seeking an inexpensive, readily available, clinical, screening, and field surveillance test of airway obstruction, we determined the validity of current dogma that forced expiratory time (FET) is a good clinical test of airway obstruction yet is of no epidemiologic use given excessive intrasubject variability. Two hundred twenty-nine white male plumbers and pipefitters were evaluated by spirometry, chest roentgenography, and a standardized respiratory questionnaire during a union-sponsored asbestos screening program. Subjects were classified as having large airway obstruction (LAO), small airway obstruction (SAO) alone, or no obstruction, on the basis of standard spirometric prediction equations. Two physicians, blinded to clinical and spirometric data, independently measured FET while auscultating the trachea with a stethoscope. The FET was defined as the time taken for an individual to forcefully exhale through an open mouth from total lung capacity until airflow became inaudible. Five such times were recorded for each subject. The mean of the three times having the narrowest range was deemed the FET for calculating test sensitivity and specificity. Based on previous literature, an FET greater than or equal to 6 s was considered abnormally prolonged. Two hundred five subjects completed both spirometry and FET testing; 67 had LAO, 5 SAO, and 133 no obstruction. A total of 83 percent had three FETs reproducible within a range of less than or equal to 1 s. The sensitivity and specificity of FET for LAO were 92 and 43 percent, respectively, while for SAO alone, 60 and 44 percent, respectively. Overall, FET misclassified 56 percent of nonobstructed subjects. Adjusting the normal-abnormal cutoff points for both FET and SAO minimally improved the performance of FET. Although FET is a simple, inexpensive, sensitive, and fairly reproducible clinical test of LAO, it cannot be recommended as a clinical or an epidemiologic tool because of its extremely low specificity.

  11. Usability Evaluation of a Flight-Deck Airflow Hazard Visualization System

    NASA Technical Reports Server (NTRS)

    Aragon, Cecilia R.

    2004-01-01

    Many aircraft accidents each year are caused by encounters with unseen airflow hazards near the ground, such as vortices, downdrafts, low level wind shear, microbursts, or turbulence from surrounding vegetation or structures near the landing site. These hazards can be dangerous even to airliners; there have been hundreds of fatalities in the United States in the last two decades attributable to airliner encounters with microbursts and low level wind shear alone. However, helicopters are especially vulnerable to airflow hazards because they often have to operate in confined spaces and under operationally stressful conditions (such as emergency search and rescue, military or shipboard operations). Providing helicopter pilots with an augmented-reality display visualizing local airflow hazards may be of significant benefit. However, the form such a visualization might take, and whether it does indeed provide a benefit, had not been studied before our experiment. We recruited experienced military and civilian helicopter pilots for a preliminary usability study to evaluate a prototype augmented-reality visualization system. The study had two goals: first, to assess the efficacy of presenting airflow data in flight; and second, to obtain expert feedback on sample presentations of hazard indicators to refine our design choices. The study addressed the optimal way to provide critical safety information to the pilot, what level of detail to provide, whether to display specific aerodynamic causes or potential effects only, and how to safely and effectively shift the locus of attention during a high-workload task. Three-dimensional visual cues, with varying shape, color, transparency, texture, depth cueing, and use of motion, depicting regions of hazardous airflow, were developed and presented to the pilots. The study results indicated that such a visualization system could be of significant value in improving safety during critical takeoff and landing operations, and also

  12. Functional tension nose as a cause of nasal airway obstruction.

    PubMed

    Kantas, Ilias V; Papadakis, Chariton E; Balatsouras, Dimitrios G; Vafiadis, Marinos; Korres, Stavros G; Panagiotakopoulou, Aggeliki; Danielidis, Vassilios

    2007-09-01

    The purpose of this prospective study was to evaluate the influence of functional tension nose in nasal obstruction and to discuss its frequency and management. Over the years 2000-2006, 153 patients underwent revision operation for nasal obstruction in our rhinoplastic center. Twenty-two of them (14.37%) suffered from functional tension nose. All 22 patients refused rhinoplasty during primary septoplasty. Sixteen of them had a kyphotic nose and the rest six cases suffered from hanging columella (drooped nose). Eighteen of them underwent primary rhinoplasty in combination with caudal diminution under general anesthesia. The other four patients refused rhinoplasty, and under local anesthesia their tip was deprojected and reprojected. Marked improvement in nasal airflow was noted at the most recent follow-up evaluation in 20 patients out of 22 (90.91%). The mean length of follow-up was 8 months (ranging from 4 to 12 months). All follow-up results were based on office examination and pre- and post-operative computer-assisted rhinomanometry evaluation. In only two cases results were not efficient enough. Our study strongly suggests that tension nose is a usual misdiagnosed cause of nasal obstruction. This problem is concealed under a "kyphotic", "big", or "pinocchio" nose. Usually the functional defect is spontaneously corrected during conventional rhinoplasty. However, tip should be deprojected and reprojected in cases where the patient refuses cosmetic intervention and surgeon tries to resolve his functional problem.

  13. Drug-induced sleep endoscopy in the identification of obstruction sites in patients with obstructive sleep apnea: a systematic review.

    PubMed

    Viana, Alonço da Cunha; Thuler, Luiz Claudio Santos; Araújo-Melo, Maria Helena de

    2015-01-01

    Obstructive sleep apnea syndrome has multifactorial causes. Although indications for surgery are evaluated by well-known diagnostic tests in the awake state, these do not always correlate with satisfactory surgical results. To undertake a systematic review on endoscopy during sleep, as one element of the diagnosis routine, aiming to identify upper airway obstruction sites in adult patients with OSAS. By means of electronic databases, a systematic review was performed of studies using drug-induced sleep endoscopy to identify obstruction sites in patients with OSAS. Ten articles were selected that demonstrated the importance of identifying multilevel obstruction, especially in relation to retrolingual and laryngeal collapse in OSAS. DISE is an additional method to reveal obstruction sites that have not been detected in awake patients. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  14. Multi-ethnic meta-analysis identifies RAI1 as a possible obstructive sleep apnea related quantitative trait locus in men

    USDA-ARS?s Scientific Manuscript database

    Obstructive sleep apnea (OSA) is a common heritable disorder displaying marked sexual dimorphism in disease prevalence and progression. Previous genetic association studies have identified a few genetic loci associated with OSA and related quantitative traits, but they have only focused on single et...

  15. Ethmoidectomy combined with superior meatus enlargement increases olfactory airflow

    PubMed Central

    Kondo, Kenji; Nomura, Tsutomu; Yamasoba, Tatsuya

    2017-01-01

    Objectives The relationship between a particular surgical technique in endoscopic sinus surgery (ESS) and airflow changes in the post‐operative olfactory region has not been assessed. The present study aimed to compare olfactory airflow after ESS between conventional ethmoidectomy and ethmoidectomy with superior meatus enlargement, using virtual ESS and computational fluid dynamics (CFD) analysis. Study Design Prospective computational study. Materials and Methods Nasal computed tomography images of four adult subjects were used to generate models of the nasal airway. The original preoperative model was digitally edited as virtual ESS by performing uncinectomy, ethmoidectomy, antrostomy, and frontal sinusotomy. The following two post‐operative models were prepared: conventional ethmoidectomy with normal superior meatus (ESS model) and ethmoidectomy with superior meatus enlargement (ESS‐SM model). The calculated three‐dimensional nasal geometries were confirmed using virtual endoscopy to ensure that they corresponded to the post‐operative anatomy observed in the clinical setting. Steady‐state, laminar, inspiratory airflow was simulated, and the velocity, streamline, and mass flow rate in the olfactory region were compared among the preoperative and two postoperative models. Results The mean velocity in the olfactory region, number of streamlines bound to the olfactory region, and mass flow rate were higher in the ESS‐SM model than in the other models. Conclusion We successfully used an innovative approach involving virtual ESS, virtual endoscopy, and CFD to assess postoperative outcomes after ESS. It is hypothesized that the increased airflow to the olfactory fossa achieved with ESS‐SM may lead to improved olfactory function; however, further studies are required. Level of Evidence NA. PMID:28894833

  16. Estimating subglottal pressure via airflow interruption with auditory masking.

    PubMed

    Hoffman, Matthew R; Jiang, Jack J

    2009-11-01

    Current noninvasive measurement of subglottal pressure using airflow interruption often produces inconsistent results due to the elicitation of audio-laryngeal reflexes. Auditory feedback could be considered as a means of ensuring measurement accuracy and precision. The purpose of this study was to determine if auditory masking could be used with the airflow interruption system to improve intrasubject consistency. A prerecorded sample of subject phonation was played on a loop over headphones during the trials with auditory masking. This provided subjects with a target pitch and blocked out distracting ambient noise created by the airflow interrupter. Subglottal pressure was noninvasively measured using the airflow interruption system. Thirty subjects, divided into two equal groups, performed 10 trials without auditory masking and 10 trials with auditory masking. Group one performed the normal trials first, followed by the trials with auditory masking. Group two performed the auditory masking trials first, followed by the normal trials. Intrasubject consistency was improved by adding auditory masking, resulting in a decrease in average intrasubject standard deviation from 0.93+/-0.51 to 0.47+/-0.22 cm H(2)O (P < 0.001). Auditory masking can be used effectively to combat audio-laryngeal reflexes and aid subjects in maintaining constant glottal configuration and frequency, thereby increasing intrasubject consistency when measuring subglottal pressure. By considering auditory feedback, a more reliable method of measurement was developed. This method could be used by clinicians, as reliable, immediately available values of subglottal pressure are useful in evaluating laryngeal health and monitoring treatment progress.

  17. Bacterial burden in the operating room: impact of airflow systems.

    PubMed

    Hirsch, Tobias; Hubert, Helmine; Fischer, Sebastian; Lahmer, Armin; Lehnhardt, Marcus; Steinau, Hans-Ulrich; Steinstraesser, Lars; Seipp, Hans-Martin

    2012-09-01

    Wound infections present one of the most prevalent and frequent complications associated with surgical procedures. This study analyzes the impact of currently used ventilation systems in the operating room to reduce bacterial contamination during surgical procedures. Four ventilation systems (window-based ventilation, supported air nozzle canopy, low-turbulence displacement airflow, and low-turbulence displacement airflow with flow stabilizer) were analyzed. Two hundred seventy-seven surgical procedures in 6 operating rooms of 5 different hospitals were analyzed for this study. Window-based ventilation showed the highest intraoperative contamination (13.3 colony-forming units [CFU]/h) followed by supported air nozzle canopy (6.4 CFU/h; P = .001 vs window-based ventilation) and low-turbulence displacement airflow (3.4 and 0.8 CFU/h; P < .001 vs window-based ventilation and supported air nozzle canopy). The highest protection was provided by the low-turbulence displacement airflow with flow stabilizer (0.7 CFU/h), which showed a highly significant difference compared with the best supported air nozzle canopy theatre (3.9 CFU/h; P < .001). Furthermore, this system showed no increase of contamination in prolonged durations of surgical procedures. This study shows that intraoperative contamination can be significantly reduced by the use of adequate ventilation systems. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  18. Beach-dune dynamics: Spatio-temporal patterns of aeolian sediment transport under complex offshore airflow

    NASA Astrophysics Data System (ADS)

    Lynch, K.; Jackson, D.; Delgado-Fernandez, I.; Cooper, J. A.; Baas, A. C.; Beyers, M.

    2010-12-01

    This study examines sand transport and wind speed across a beach at Magilligan Strand, Northern Ireland, under offshore wind conditions. Traditionally the offshore component of local wind regimes has been ignored when quantifying beach-dune sediment budgets, with the sheltering effect of the foredune assumed to prohibit grain entrainment on the adjoining beach. Recent investigations of secondary airflow patterns over coastal dunes have suggested this may not be the case, that the turbulent nature of the airflow in these zones enhances sediment transport potential. Beach sediment may be delivered to the dune toe by re-circulating eddies under offshore winds in coastal areas, which may explain much of the dynamics of aeolian dunes on coasts where the dominant wind direction is offshore. The present study investigated aeolian sediment transport patterns under an offshore wind event. Empirical data were collected using load cell traps, for aeolian sediment transport, co-located with 3-D ultrasonic anemometers. The instrument positioning on the sub-aerial beach was informed by prior analysis of the airflow patterns using computational fluid dynamics. The array covered a total beach area of 90 m alongshore by 65 m cross-shore from the dune crest. Results confirm that sediment transport occurred in the ‘sheltered’ area under offshore winds. Over short time and space scales the nature of the transport is highly complex; however, preferential zones for sand entrainment may be identified. Alongshore spatial heterogeneity of sediment transport seems to show a relationship to undulations in the dune crest, while temporal and spatial variations may also be related to the position of the airflow reattachment zone. These results highlight the important feedbacks between flow characteristics and transport in a complex three dimensional surface.

  19. [Chronic obstructive pulmonary disease (COPD). Current concepts and new therapeutic options].

    PubMed

    Klemmer, A; Greulich, T; Koczulla, A R; Vogelmeier, C F

    2014-04-01

    Chronic obstructive pulmonary disease (COPD) is a very common chronic disease with increasing prevalence. Inhaled particles and gases (in particular tobacco smoke) induce chronic inflammation of the airways accompanied by a not fully reversible airflow limitation. Destruction of lung tissue and deterioration of gas exchange may follow. In parallel, several comorbidities can be observed. The COPD assessment was revised and now takes into account lung function, the patients' symptoms, and history of exacerbations. More recently, several new long-acting bronchodilators received approval. Combination products, consisting of long-acting β2-agonists and long-acting anticholinergics, and a new combination of a long-acting β-agonist and an inhaled corticosteroid will follow in the near future. Smoking cessation is of central importance.

  20. [Midface alterations in childhood as pathogenesis of obstructive sleep apnea syndrome].

    PubMed

    Rangel Chávez, José de Jesús; Espinosa Martínez, Cynthia; Medina Serpa, Aldo Uzziel

    The onset of nasal breathing sets a genetically determined impulse to aerate the face cavities or paranasal sinuses, which in turn initiate its growth creating the useful trafficable space for air during the development of the midface. Considering the evidence that the upper airway obstruction has a primary role in the pathogenesis of respiratory sleep disorders, any condition that causes a permanent difficulty to the nasal airflow during breathing will cause hypo-development of the required amplitude in this airway, reducing the growth stimulation of the sinus cavities and altering the development of the midface as a whole. Copyright © 2016 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.

  1. [Quality of life in patients with obstructive sleep apnea].

    PubMed

    Kasibowska-Kuźniar, Kamilla; Jankowska, Renata; Kuźniar, Tomasz

    2004-11-01

    Obstructive sleep apnea syndrome (OSA) is a condition affecting up to 5% of the population, in which episodes of upper airway obstruction lead to temporary cessation of airflow, disturbed sleep architecture and daily somnolence. The health consequences of OSA also include psychological and cognitive deficits, an increased risk of systemic and pulmonary hypertension, coronary disease, bradyarrhythmias and motor vehicle accidents. Symptoms and complications of OSA lead to a significant decrease of health-related quality of life (HRQOL) of affected patients. We review the current literature on HRQOL effects of OSA and its treatment. There is good evidence of beneficial effect of the continuous positive airway pressure (CPAP) therapy on the quality of life of patients with OSA. Improvements in HRQOL are most appreciable in patients with moderate to severe OSA, although they also seem to be present in selected patients with mild OSA. The effects of dental devices and surgical procedures on HRQOL of patients with OSA have not been studied in randomized, placebo-controlled trials. Health-related quality of life has become one of the major outcome measures in patients with sleep apnea. Assessment of HRQOL has become a crucial part of any clinical study involving patients with OSA.

  2. Study on airflow characteristics in the semi-closed irregular narrow flow channel

    NASA Astrophysics Data System (ADS)

    Jin, Yuzhen; Hu, Xiaodong; Zhu, Linhang; Hu, Xudong; Jin, Yingzi

    2016-04-01

    The air-jet loom is widely used in the textile industry. The interaction mechanism of airflow and yarn is not clear in such a narrow flow channel, the gas consumption is relatively large, the yarn motion is unstable and the weft insertion is often interrupted during the operation. In order to study the characteristics of the semi-closed flow field in profiled dents, the momentum conservation equation is modified and the model parameters and boundary conditions are set. Compared with the different r, the ratio of profiled dent's thickness and gap, the results show that the smaller the r is, the smaller the velocity fluctuations of the airflow is. When the angle of profiled dents α is close to zero, the diffusion of the airflow will be less. The experiment is also conducted to verify the result of the simulation with a high-speed camera and pressure sensor in profiled dents. The airflow characteristics in the semi-closed irregular narrow flow channel in the paper would provide the theoretical basis for optimizing the weft insertion process of the air-jet loom.

  3. The difficult asthmatic.

    PubMed

    Gregg, I

    1977-01-01

    The most common reason why asthma presents difficulties in management is the failure to treat it with drugs which are appropriate and taken in adequate dosage. An understanding of the pathophysiology and aetiology of asthma is essential if full advantage is to be taken of the wide range of drugs now available for treating it. Airflow obstruction due to bronchial muscle constriction is usually readily reversible by bronchodilators, whereas that due to the inflammatory component of asthma is refractory to the latter and can only be reversed by steroids. Refractory airflow obstruction is liable to be confused with irreversible obstruction which occurs in those patients whose asthma is complicated by chronic obstructive bronchitis or other lung disease. The choice between symptomatic, preventive and suppressive forms of treatment should be made only after a careful assessment has been carried out with objective measurement of airflow obstruction. The Wright peak flow meter is unsurpassed for this purpose. By its means it should be possible to estimate how much of a patient's airflow obstruction is readily reversible, how much is refractory and how much is irreversible. In general, the aim of treatment is to relieve airflow obstruction rather than to counteract supposed aetiological factors. Both doctor and patient must understand the purpose, limitations and possible dangers of any drug which is prescribed. Steroids are the only form of treatment which is effective in persistent refractory asthma. Prejudice against steroids has resulted in many patients being deprived of their benefit, but this situation may change with the recent introduction of steroid aerosols.

  4. Toward numerical simulations of fluid-structure interactions for investigation of obstructive sleep apnea

    NASA Astrophysics Data System (ADS)

    Huang, Chien-Jung; Huang, Shao-Ching; White, Susan M.; Mallya, Sanjay M.; Eldredge, Jeff D.

    2016-04-01

    Obstructive sleep apnea (OSA) is a medical condition characterized by repetitive partial or complete occlusion of the airway during sleep. The soft tissues in the airway of OSA patients are prone to collapse under the low-pressure loads incurred during breathing. This paper describes efforts toward the development of a numerical tool for simulation of air-tissue interactions in the upper airway of patients with sleep apnea. A procedure by which patient-specific airway geometries are segmented and processed from dental cone-beam CT scans into signed distance fields is presented. A sharp-interface embedded boundary method based on the signed distance field is used on Cartesian grids for resolving the airflow in the airway geometries. For simulation of structure mechanics with large expected displacements, a cut-cell finite element method with nonlinear Green strains is used. The fluid and structure solvers are strongly coupled with a partitioned iterative algorithm. Preliminary results are shown for flow simulation inside the three-dimensional rigid upper airway of patients with obstructive sleep apnea. Two validation cases for the fluid-structure coupling problem are also presented.

  5. PDK1/Akt/PDE4D axis identified as a target for asthma remedy synergistic with β2 AR agonists by a natural agent arctigenin.

    PubMed

    Fang, R; Cui, Q; Sun, J; Duan, X; Ma, X; Wang, W; Cheng, B; Liu, Y; Hou, Y; Bai, G

    2015-12-01

    Asthma is a heterogenetic disorder characterized by chronic inflammation with variable airflow obstruction and airway hyper-responsiveness. As the most potent and popular bronchodilators, β2 adrenergic receptor (β2 AR) agonists bind to the β2 ARs that are coupled via a stimulatory G protein to adenylyl cyclase, thereby improving cAMP accumulation and resulting in airway smooth muscle relaxation. We previously demonstrated arctigenin had a synergistic function with the β2 AR agonist, but the target for this remained elusive. Chemical proteomics capturing was used to enrich and uncover the target of arctigenin in human bronchial smooth muscle cells, and reverse docking and molecular dynamic stimulation were performed to evaluate the binding of arctigenin and its target. In vitro enzyme activities and protein levels were demonstrated with special kits and Western blotting. Finally, guinea pig tracheal muscle segregation and ex vivo function were analysed. Arctigenin bound to PDK1 with an ideal binding free energy -25.45 kcal/mol and inhibited PDK1 kinase activity without changing its protein level. Additionally, arctigenin reduced PKB/Akt-induced phosphorylation of PDE4D, which was first identified in this study. Attenuation of PDE4D resulted in cAMP accumulation in human bronchial smooth muscle. The inhibition of PDK1 showed a synergistic function with β2 AR agonists and relaxed the constriction of segregated guinea pig tracheal muscle. The PDK1/Akt/PDE4D axis serves as a novel asthma target, which may benefit airflow obstruction. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Effects of mass airflow rate through an open-circuit gas quantification system when measuring carbon emissions.

    PubMed

    Gunter, Stacey A; Bradford, James A; Moffet, Corey A

    2017-01-01

    Methane (CH) and carbon dioxide (CO) represent 11 and 81%, respectively, of all anthropogenic greenhouse gas emissions. Agricultural CH emissions account for approximately 43% of all anthropogenic CH emissions. Most agricultural CH emissions are attributed to enteric fermentation within ruminant livestock; hence, the heightened interest in quantifying and mitigating this source. The automated, open-circuit gas quantification system (GQS; GreenFeed, C-Lock, Inc., Rapid City, SD) evaluated here can be placed in a pasture with grazing cattle and can measure their CH and CO emissions with spot sampling. However, improper management of the GQS can have an erroneous effect on emission estimates. One factor affecting the quality of emission estimates is the airflow rates through the GQS to ensure a complete capture of the breath cloud emitted by the animal. It is hypothesized that at lower airflow rates this cloud will be incompletely captured. To evaluate the effect of airflow rate through the GQS on emission estimates, a data set was evaluated with 758 CO and CH emission estimates with a range in airflows of 10.7 to 36.6 L/s. When airflow through the GQS was between 26.0 and 36.6 L/s, CO and CH emission estimates were not affected ( = 0.14 and 0.05, respectively). When airflow rates were less than 26.0 L/s, CO and CH emission estimates were lower and decreased as airflow rate decreased ( < 0.0001). We hypothesize that when airflow through the GQS decreases below 26 L/s, breath capture was incomplete and CO and CH emissions are underestimated. Maintaining mass airflow through a GQS at rates greater than 26 L/s is important for producing high quality CO and CH emission estimates.

  7. Thermal sensation and comfort during exposure to local airflow to face or legs.

    PubMed

    Yamashita, Kazuaki; Matsuo, Juntaro; Tochihara, Yutaka; Kondo, Youichiro; Takayama, Shizuka; Nagayama, Hiroki

    2005-01-01

    The present study examined the contribution of local airflow temperature to thermal sensation and comfort in humans. Eight healthy male students were exposed to local airflow to their faces (summer condition) or legs (winter condition) for 30 minutes. Local airflow temperature (Tf) was maintained at 18 degrees C to 36 degrees C, and ambient temperature (Ta) was maintained at 17.4 degrees C to 31.4 degrees C. Each subject was exposed to 16 conditions chosen from the combination of Tf and Ta. Based on the results of multiple regression analysis, the standardized partial regression coefficient of Tf and Ta were determined to be 0.93 and 0.13 in the summer condition, and 0.71 and 0.36 in the winter condition at the end of the exposure. Also, thermal comfort was observed to depend closely on the interrelation between Tf and Ta. The present data suggested that local airflow temperature is an important thermal factor regarding thermal sensation and comfort.

  8. Spirometry, Static Lung Volumes, and Diffusing Capacity.

    PubMed

    Vaz Fragoso, Carlos A; Cain, Hilary C; Casaburi, Richard; Lee, Patty J; Iannone, Lynne; Leo-Summers, Linda S; Van Ness, Peter H

    2017-09-01

    Spirometric Z-scores from the Global Lung Initiative (GLI) rigorously account for age-related changes in lung function and are thus age-appropriate when establishing spirometric impairments, including a restrictive pattern and air-flow obstruction. However, GLI-defined spirometric impairments have not yet been evaluated regarding associations with static lung volumes (total lung capacity [TLC], functional residual capacity [FRC], and residual volume [RV]) and gas exchange (diffusing capacity). We performed a retrospective review of pulmonary function tests in subjects ≥40 y old (mean age 64.6 y), including pre-bronchodilator measures for: spirometry ( n = 2,586), static lung volumes by helium dilution with inspiratory capacity maneuver ( n = 2,586), and hemoglobin-adjusted single-breath diffusing capacity ( n = 2,508). Using multivariable linear regression, adjusted least-squares means (adj LS Means) were calculated for TLC, FRC, RV, and hemoglobin-adjusted single-breath diffusing capacity. The adj LS Means were expressed with and without height-cubed standardization and stratified by GLI-defined spirometry, including normal ( n = 1,251), restrictive pattern ( n = 663), and air-flow obstruction (mild, [ n = 128]; moderate, [ n = 150]; and severe, [ n = 394]). Relative to normal spirometry, restrictive-pattern had lower adj LS Means for TLC, FRC, RV, and hemoglobin-adjusted single-breath diffusing capacity ( P ≤ .001). Conversely, relative to normal spirometry, mild, moderate, and severe air-flow obstruction had higher adj LS Means for FRC and RV ( P < .001). However, only mild and moderate air-flow obstruction had higher adj LS Means for TLC ( P < .001), while only moderate and severe air-flow obstruction had higher adj LS Means for RV/TLC ( P < .001) and lower adj LS Means for hemoglobin-adjusted single-breath diffusing capacity ( P < .001). Notably, TLC (calculated as FRC + inspiratory capacity) was not increased in severe air-flow obstruction ( P ≥ .11

  9. Airflow dispersion in unsaturated soil.

    PubMed

    Gidda, T; Cann, D; Stiver, W H; Zytner, R G

    2006-01-05

    Dispersion data is abundant for water flow in the saturated zone but is lacking for airflow in unsaturated soil. However, for remediation processes such as soil vapour extraction, characterization of airflow dispersion is necessary for improved modelling and prediction capabilities. Accordingly, gas-phase tracer experiments were conducted in five soils ranging from uniform sand to clay at air-dried and wetted conditions. The disturbed soils were placed in one-dimensional stainless steel columns, with sulfur hexafluoride used as the inert tracer. The tested interstitial velocities were typical of those present in the vicinity of a soil vapour extraction well, while wetting varied according to the water-holding capacity of the soils. Results gave dispersivities that varied between 0.42 and 2.6 cm, which are typical of values in the literature. In air-dried soils, dispersion was found to increase with the pore size variability of the soil. For wetted soils, particle shape was an important factor at low water contents, while at high water contents, the proportion of macroporous space filled with water was important. The relative importance of diffusion decreased with increasing interstitial velocity and water content and was, in general, found to be minor compared to mechanical mixing across all conditions studied.

  10. Chronic obstructive pulmonary disease--a treatable disease.

    PubMed

    Osthoff, Mirjam; Jenkins, Christine; Leuppi, Jörg D

    2013-04-11

    Chronic obstructive pulmonary disease (COPD) is a global health challenge and a leading cause of death worldwide. Several risk factors have been identified, with cigarette smoking being the most important. Diagnostic assessment is based on symptoms, risk of exacerbations and results of lung function testing. A fixed post-bronchodilator ratio for forced expiratory volume in one second to forced expiratory volume (FEV1/FVC) of <0.7 is required to make the diagnosis, and the severity of airflow obstruction defines the grade according to GOLD (Global Strategy for the Diagnosis, Management, and Prevention of COPD). The GOLD strategy makes therapeutic recommendations taking into account the grade, symptomatic assessment and future risk of exacerbations. This review focuses on the therapeutic options for COPD, in accordance with the GOLD strategy. Smoking cessation is the most effective treatment option in all COPD stages. Bronchodilators, namely long-acting antimuscarinic drugs and long-acting beta-agonists, form the mainstay of treatment in COPD. Patients with frequent exacerbations also benefited from the addition of inhaled corticosteroids. Roflumilast is an add-on option for patients with severe COPD. Several controversies are the subject of discussion: (1.) whether pharmacotherapy can modify the natural history of COPD; (2.) whether pharmacotherapy should be started in the early stages of COPD; (3.) the impact of therapy on comorbidities; (4.) whether patients benefit from a combination therapy with a long-acting beta-agonist, a long-acting antimuscarinic drug and an inhaled corticosteroid; (5.) step-down therapy. This overview also reviews the evidence for recommended vaccines in COPD, as well as nonpharmacological therapies. Rehabilitation is an essential part of COPD treatment. Oxygen therapy, noninvasive nocturnal ventilation and surgical treatment options only apply to a highly selected group of patients. Disease management programmes and guideline adherence

  11. Resistance to airflow through bedding materials used in infancy.

    PubMed Central

    Hatch, D J; Helms, P; Matthew, D J; Skinner, D

    1982-01-01

    Various bedding materials used in infancy, including duvets (or continental quilts), were tested for airflow using the British Standards Institution tests for pillows or fabrics. Resistance was also measured when the items were placed on a dummy infant face. Measurements were made on washed and unwashed garments, which were tested both dry and wet. Results suggest that all the bedding materials tested are safe for use even in the newborn period. The duvets produced slightly lower resistance to breathing than conventional blankets and sheets. In view of the wide variety of infant bedding fabrics it seems desirable for standard airflow performance requirements to be introduced. PMID:7092309

  12. Microfabricated airflow nozzle for microencapsulation of living cells into 150 micrometer microcapsules.

    PubMed

    Sugiura, Shinji; Oda, Tatsuya; Aoyagi, Yasuyuki; Matsuo, Ryota; Enomoto, Tsuyoshi; Matsumoto, Kunio; Nakamura, Toshikazu; Satake, Mitsuo; Ochiai, Atsushi; Ohkohchi, Nobuhiro; Nakajima, Mitsutoshi

    2007-02-01

    Microencapsulation of genetically engineered cells has attracted much attention as an alternative nonviral strategy to gene therapy. Though smaller microcapsules (i.e. less than 300 microm) theoretically have various advantages, technical limitations made it difficult to prove this notion. We have developed a novel microfabricated device, namely a micro-airflow-nozzle (MAN), to produce 100 to 300 microm alginate microcapsules with a narrow size distribution. The MAN is composed of a nozzle with a 60 microm internal diameter for an alginate solution channel and airflow channels next to the nozzle. An alginate solution extruded through the nozzle was sheared by the airflow. The resulting alginate droplets fell directly into a CaCl2 solution, and calcium alginate beads were formed. The device enabled us to successfully encapsulate living cells into 150 microm microcapsules, as well as control microcapsule size by simply changing the airflow rate. The encapsulated cells had a higher growth rate and greater secretion activity of marker protein in 150 microm microcapsules compared to larger microcapsules prepared by conventional methods because of their high diffusion efficiency and effective scaffold surface area. The advantages of smaller microcapsules offer new prospects for the advancement of microencapsulation technology.

  13. Chronic obstructive pulmonary disease

    PubMed Central

    Vijayan, V.K.

    2013-01-01

    The global prevalence of physiologically defined chronic obstructive pulmonary disease (COPD) in adults aged >40 yr is approximately 9-10 per cent. Recently, the Indian Study on Epidemiology of Asthma, Respiratory Symptoms and Chronic Bronchitis in Adults had shown that the overall prevalence of chronic bronchitis in adults >35 yr is 3.49 per cent. The development of COPD is multifactorial and the risk factors of COPD include genetic and environmental factors. Pathological changes in COPD are observed in central airways, small airways and alveolar space. The proposed pathogenesis of COPD includes proteinase-antiproteinase hypothesis, immunological mechanisms, oxidant-antioxidant balance, systemic inflammation, apoptosis and ineffective repair. Airflow limitation in COPD is defined as a postbronchodilator FEV1 (forced expiratory volume in 1 sec) to FVC (forced vital capacity) ratio <0.70. COPD is characterized by an accelerated decline in FEV1. Co morbidities associated with COPD are cardiovascular disorders (coronary artery disease and chronic heart failure), hypertension, metabolic diseases (diabetes mellitus, metabolic syndrome and obesity), bone disease (osteoporosis and osteopenia), stroke, lung cancer, cachexia, skeletal muscle weakness, anaemia, depression and cognitive decline. The assessment of COPD is required to determine the severity of the disease, its impact on the health status and the risk of future events (e.g., exacerbations, hospital admissions or death) and this is essential to guide therapy. COPD is treated with inhaled bronchodilators, inhaled corticosteroids, oral theophylline and oral phosphodiesterase-4 inhibitor. Non pharmacological treatment of COPD includes smoking cessation, pulmonary rehabilitation and nutritional support. Lung volume reduction surgery and lung transplantation are advised in selected severe patients. Global strategy for the diagnosis, management and prevention of Chronic Obstructive Pulmonary Disease guidelines

  14. Diagnostic management of chronic obstructive pulmonary disease.

    PubMed

    Broekhuizen, B D L; Sachs, A P E; Hoes, A W; Verheij, T J M; Moons, K G M

    2012-01-01

    Detection of early chronic obstructive pulmonary disease (COPD) in patients presenting with respiratory symptoms is recommended; however, diagnosing COPD is difficult because a single gold standard is not available. The aim of this article is to review and interpret the existing evidence, theories and consensus on the individual parts of the diagnostic work-up for COPD. Relevant articles are discussed under the subheadings: history taking, physical examination, spirometry and additional lung function assessment. Wheezing, cough, phlegm and breathlessness on exertion are suggestive signs for COPD. The diagnostic value of the physical examination is limited, except for auscultated pulmonary wheezing or reduced breath sounds, increasing the probability of COPD. Spirometric airflow obstruction after bronchodilation, defined as a lowered ratio of the forced volume in one second to the forced vital capacity (FEV1/FVC ratio), is a prerequisite, but can only confirm COPD in combination with suggestive symptoms. Different thresholds are being recommended to define low FEV1/FVC, including a fixed threshold, and one varying with gender and age; however, the way physicians interpret these thresholds in their assessment is not well known. Body plethysmography allows a more complete assessment of pulmonary function, providing results on the total lung capacity and the residual volume and is indicated when conventional spirometry results are inconclusive. Chest radiography has no diagnostic value for COPD but is useful to exclude alternative diagnoses such as heart failure or lung cancer. Extensive history taking is of key importance in diagnosing COPD.

  15. The Presence of Chronic Mucus Hypersecretion across Adult Life in Relation to Chronic Obstructive Pulmonary Disease Development

    PubMed Central

    Shaheen, Seif O.

    2016-01-01

    Rationale: Chronic mucus hypersecretion (CMH) is common among smokers and is associated with chronic obstructive pulmonary disease development and progression. Objectives: To understand how the relationships between smoking, CMH, and chronic obstructive pulmonary disease develop during adult life, and facilitate earlier disease detection and intervention. Methods: We analyzed data on CMH, smoking, and lung function prospectively collected by the Medical Research Council National Survey of Health and Development, a nationally representative British cohort followed since birth in 1946. We analyzed the longitudinal relationships between smoking and CMH, how symptoms during life related to airflow limitation at 60–64 years, and how CMH duration between ages 43 and 60–64 years related to concurrent FEV1 decline. Measurements and Main Results: From 5,362 individuals enrolled at birth, 4,427 contributed data between ages 20 and 64 years (52% male; 63% ever-smoker). Among smokers CMH prevalence escalated between ages 36 and 43 from 7.6 ± 2.0% to 13.0 ± 2.6%. At these ages, symptoms were associated with a higher risk of subsequent airflow limitation (odds ratio [95% confidence interval], 3.70 [1.62–8.45] and 4.11 [1.85–9.13], respectively). Across adult life, CMH followed a dynamic remitting–relapsing course. Symptom prevalence following smoking cessation returned to levels seen among never-smokers. The longer CMH was present across three occasions (ages 43, 53, and 60–64 yr), the greater the concurrent FEV1 decline, corresponding to an additional decrement of 3.6 ± 2.5 ml/yr per occasion that CMH was present (P = 0.005). Conclusions: CMH among middle-aged smokers represents an early developmental phase of chronic obstructive pulmonary disease. Smoking-related CMH usually resolves following smoking cessation but the longer its duration the greater the FEV1 lost, suggesting the course of CMH across adult life may reflect the underlying course

  16. A new Strategy to Improve Drug Delivery to the Maxillary Sinuses: The Frequency Sweep Acoustic Airflow.

    PubMed

    El Merhie, Amira; Navarro, Laurent; Delavenne, Xavier; Leclerc, Lara; Pourchez, Jérémie

    2016-05-01

    Enhancement of intranasal sinus deposition involves nebulization of a drug superimposed by an acoustic airflow. We investigated the impact of fixed frequency versus frequency sweep acoustic airflow on the improvement of aerosolized drug penetration into maxillary sinuses. Fixed frequency and frequency sweep acoustic airflow were generated using a nebulizing system of variable frequency. The effect of sweep cycle and intensity variation was studied on the intranasal sinus deposition. We used a nasal replica created from CT scans using 3D printing. Sodium fluoride and gentamicin were chosen as markers. Studies performed using fixed frequency acoustic airflow showed that each of maxillary sinuses of the nasal replica required specific frequency for the optimal aerosol deposition. Intranasal sinus drug deposition experiments under the effect of the frequency sweep acoustic airflow showed an optimal aerosol deposition into both maxillary sinus of the nasal replica. Studies on the effect of the duration of the sweep cycle showed that the shorter the cycle the better the deposition. We demonstrate the benefit of frequency sweep acoustic airflow on drug deposition into maxillary sinuses. However further in vivo studies have to be conducted since delivery rates cannot be obviously determined from a nasal replica.

  17. Elasto-Aerodynamics-Driven Triboelectric Nanogenerator for Scavenging Air-Flow Energy.

    PubMed

    Wang, Shuhua; Mu, Xiaojing; Wang, Xue; Gu, Alex Yuandong; Wang, Zhong Lin; Yang, Ya

    2015-10-27

    Efficient scavenging the kinetic energy from air-flow represents a promising approach for obtaining clean, sustainable electricity. Here, we report an elasto-aerodynamics-driven triboelectric nanogenerator (TENG) based on contact electrification. The reported TENG consists of a Kapton film with two Cu electrodes at each side, fixed on two ends in an acrylic fluid channel. The relationship between the TENG output power density and its fluid channel dimensions is systematically studied. TENG with a fluid channel size of 125 × 10 × 1.6 mm(3) delivers the maximum output power density of about 9 kW/m(3) under a loading resistance of 2.3 MΩ. Aero-elastic flutter effect explains the air-flow induced vibration of Kapton film well. The output power scales nearly linearly with parallel wiring of multiple TENGs. Connecting 10 TENGs in parallel gives an output power of 25 mW, which allows direct powering of a globe light. The TENG is also utilized to scavenge human breath induced air-flow energy to sustainably power a human body temperature sensor.

  18. Dust control by air-blocking shelves and dust collector-to-bailing airflow ratios for a surface mine drill shroud

    PubMed Central

    Zheng, Y.; Reed, W.R.; Potts, J.D.; Li, M.; Rider, J.P.

    2018-01-01

    The National Institute for Occupational Safety and Health (NIOSH) recently developed a series of validated models utilizing computational fluid dynamics (CFD) to study the effects of air-blocking shelves on airflows and respirable dust distribution associated with medium-sized surface blasthole drill shrouds as part of a dry dust collector system. Using validated CFD models, three different air-blocking shelves were included in the present study: a 15.2-cm (6-in.)-wide shelf; a 7.6-cm (3-in.)-wide shelf; and a 7.6-cm (3-in.)-wide shelf at four different shelf heights. In addition, the dust-collector-to-bailing airflow ratios of 1.75:1, 1.5:1, 1.25:1 and 1:1 were evaluated for the 15.2-cm (6-in.)-wide air-blocking shelf. This paper describes the methodology used to develop the CFD models. The effects of air-blocking shelves and dust collector-to-bailing airflow ratios were identified by the study, and problem regions were revealed under certain conditions.

  19. Numerical simulation of airflow around the evaporator in the closed space

    NASA Astrophysics Data System (ADS)

    Puchor, Tomáš; Banovčan, Roman; Lenhard, Richard

    2018-06-01

    The article deals with a numerical simulation of the forced airflow around a evaporator with the finned tubes in the electrotechnical box, by finite volume method in the program ANSYS Workbench. The work contains an analysis of the impact of forced airflow on the evaporator with the various seated the electrical components. The aim of the work is to find out the most effective way of heat dissipation by forced convection from the electrical components in the closed space with lowest pressure loss.

  20. Asthma–COPD Overlap. Clinical Relevance of Genomic Signatures of Type 2 Inflammation in Chronic Obstructive Pulmonary Disease

    PubMed Central

    Steiling, Katrina; van den Berge, Maarten; Hijazi, Kahkeshan; Hiemstra, Pieter S.; Postma, Dirkje S.; Lenburg, Marc E.; Spira, Avrum; Woodruff, Prescott G.

    2015-01-01

    Rationale: Chronic obstructive pulmonary disease (COPD) is a heterogeneous disease and likely includes a subgroup that is biologically comparable to asthma. Studying asthma-associated gene expression changes in COPD could add insight into COPD pathogenesis and reveal biomarkers that predict a favorable response to corticosteroids. Objectives: To determine whether asthma-associated gene signatures are increased in COPD and associated with asthma-related features. Methods: We compared disease-associated airway epithelial gene expression alterations in an asthma cohort (n = 105) and two COPD cohorts (n = 237, 171). The T helper type 2 (Th2) signature (T2S) score, a gene expression metric induced in Th2-high asthma, was evaluated in these COPD cohorts. The T2S score was correlated with asthma-related features and response to corticosteroids in COPD in a randomized, placebo-controlled trial, the Groningen and Leiden Universities study of Corticosteroids in Obstructive Lung Disease (GLUCOLD; n = 89). Measurements and Main Results: The 200 genes most differentially expressed in asthma versus healthy control subjects were enriched among genes associated with more severe airflow obstruction in these COPD cohorts (P < 0.001), suggesting significant gene expression overlap. A higher T2S score was associated with decreased lung function (P < 0.001), but not asthma history, in both COPD cohorts. Higher T2S scores correlated with increased airway wall eosinophil counts (P = 0.003), blood eosinophil percentage (P = 0.03), bronchodilator reversibility (P = 0.01), and improvement in hyperinflation after corticosteroid treatment (P = 0.019) in GLUCOLD. Conclusions: These data identify airway gene expression alterations that can co-occur in asthma and COPD. The association of the T2S score with increased severity and “asthma-like” features (including a favorable corticosteroid response) in COPD suggests that Th2 inflammation is important in a

  1. Computational and experimental study of airflow around a fan powered UVGI lamp

    NASA Astrophysics Data System (ADS)

    Kaligotla, Srikar; Tavakoli, Behtash; Glauser, Mark; Ahmadi, Goodarz

    2011-11-01

    The quality of indoor air environment is very important for improving the health of occupants and reducing personal exposure to hazardous pollutants. An effective way of controlling air quality is by eliminating the airborne bacteria and viruses or by reducing their emissions. Ultraviolet Germicidal Irradiation (UVGI) lamps can effectively reduce these bio-contaminants in an indoor environment, but the efficiency of these systems depends on airflow in and around the device. UVGI lamps would not be as effective in stagnant environments as they would be when the moving air brings the bio-contaminant in their irradiation region. Introducing a fan into the UVGI system would augment the efficiency of the system's kill rate. Airflows in ventilated spaces are quite complex due to the vast range of length and velocity scales. The purpose of this research is to study these complex airflows using CFD techniques and validate computational model with airflow measurements around the device using Particle Image Velocimetry measurements. The experimental results including mean velocities, length scales and RMS values of fluctuating velocities are used in the CFD validation. Comparison of these data at different locations around the device with the CFD model predictions are performed and good agreement was observed.

  2. Inhalation device options for the management of chronic obstructive pulmonary disease.

    PubMed

    DePietro, Michael; Gilbert, Ileen; Millette, Lauren A; Riebe, Michael

    2018-01-01

    Chronic obstructive pulmonary disease (COPD) is characterized by chronic respiratory symptoms and airflow limitation, resulting from abnormalities in the airway and/or damage to the alveoli. Primary care physicians manage the healthcare of a large proportion of patients with COPD. In addition to determining the most appropriate medication regimen, which usually includes inhaled bronchodilators with or without inhaled corticosteroids, physicians are charged with optimizing inhalation device selection to facilitate effective drug delivery and patient adherence. The large variety of inhalation devices currently available present numerous challenges for physicians that include: (1) gaining knowledge of and proficiency with operating different device classes; (2) identifying the most appropriate inhalation device for the patient; and (3) providing the necessary education and training for patients on device use. This review provides an overview of the inhalation device types currently available in the United States for delivery of COPD medications, including information on their successful operation and respective advantages and disadvantages, factors to consider in matching a device to an individual patient, the need for device training for patients and physicians, and guidance for improving treatment adherence. Finally, the review will discuss established and novel tools and technology that may aid physicians in improving education and promoting better adherence to therapy.

  3. Abnormal heart rate recovery and chronotropic incompetence on exercise in chronic obstructive pulmonary disease.

    PubMed

    Gupta, Mansi; Bansal, Vishal; Chhabra, Sunil K

    2013-08-01

    Chronotropic incompetence (CI; failure to reach the targeted heart rate (HR) on exercise) and a delayed HR recovery (HRR; ≤12 beats decline within the first minute after cessation) reflect autonomic dysfunction (AD) and predict adverse cardiac prognosis. As chronic obstructive pulmonary disease (COPD) is known to be associated with AD, we hypothesized that these patients may manifest these responses on exercise. The prevalence and predictors of these responses in COPD and their association with its severity have not been evaluated. Normoxemic, stable male patients with COPD (n = 39) and 11 healthy controls underwent lung function testing and incremental leg ergometry. HR responses were monitored during exercise and recovery to compute the HRR and CI. Of all the patients, 33 (84.6%) had at least one of the two exercise responses as abnormal, with the majority (23, 58.9%) having both an abnormal HRR and CI. The frequency of abnormal responses increased with increasing Global Initiative for Chronic Obstructive Lung Disease stage and body mass index, airflow obstruction, dyspnoea and exercise capacity index. After adjusting for smoking history and post-bronchodilator forced expiratory volume in 1 second, only a reduced diffusion capacity for carbon monoxide predicted abnormal HRR, though weakly. We concluded that abnormal HRR and CI are common in patients with COPD. These responses are observed with increasing frequency as the severity of disease increases.

  4. Stimulation of Electro-Olfactogram Responses in the Main Olfactory Epithelia by Airflow Depend on the Type 3 Adenylyl Cyclase

    PubMed Central

    Chen, Xuanmao; Xia, Zhengui; Storm, Daniel R.

    2012-01-01

    Cilia of olfactory sensory neurons (OSN) are the primary sensory organelles for olfaction. The detection of odorants by the main olfactory epithelium (MOE) depends on coupling of odorant receptors to the type 3 adenylyl cyclase (AC3) in olfactory cilia. We monitored the effect of airflow on electro-olfactogram (EOG) responses and found that the MOE of mice can sense mechanical forces generated by airflow. The airflow-sensitive EOG response in the MOE was attenuated when cAMP was increased by odorants or by forskolin suggesting a common mechanism for airflow and odorant detection. In addition, the sensitivity to airflow was significantly impaired in the MOE from AC3−/− mice. We conclude that AC3 in the MOE is required for detecting the mechanical force of airflow, which in turn may regulate odorant perception during sniffing. PMID:23136416

  5. Two-dimensional airflow modeling underpredicts the wind velocity over dunes

    PubMed Central

    Michelsen, Britt; Strobl, Severin; Parteli, Eric J. R.; Pöschel, Thorsten

    2015-01-01

    We investigate the average turbulent wind field over a barchan dune by means of Computational Fluid Dynamics. We find that the fractional speed-up ratio of the wind velocity over the three-dimensional barchan shape differs from the one obtained from two-dimensional calculations of the airflow over the longitudinal cut along the dune’s symmetry axis — that is, over the equivalent transverse dune of same size. This finding suggests that the modeling of the airflow over the central slice of barchan dunes is insufficient for the purpose of the quantitative description of barchan dune dynamics as three-dimensional flow effects cannot be neglected. PMID:26572966

  6. Patient-perceived treatment burden of chronic obstructive pulmonary disease.

    PubMed

    Harb, Nathan; Foster, Juliet M; Dobler, Claudia C

    2017-01-01

    While chronic morbidity and mortality from COPD is well documented, little is known about the treatment burden faced by patients with COPD. Patients with severe airflow obstruction (forced expiratory volume in 1 second [FEV 1 ] <50% predicted) representing different age-groups, sex, and number of comorbidities participated in a semistructured interview. Interviews were conducted until thematic saturation was reached. Interviews were recorded, transcribed, and analyzed thematically using an established treatment-burden framework. A total of 26 patients (42% male, mean age 66.7±9.8 years) with severe (n=15) or very severe (n=11) airflow limitation (mean FEV 1 32.1%±9.65% predicted) were interviewed. Participants struggled with various treatment-burden domains, predominantly with changing health behaviors, such as smoking cessation and exercise. Interviewees often only ceased smoking after a major health event, despite being advised to do so earlier by a doctor. Recommended exercise regimens, such as pulmonary rehabilitation classes, were curtailed, although some patients replaced them with light home-based exercise. Interviewees had difficulty attending medical appointments, often relying on others to transport them. Overall, COPD patients indicated they were not willing to accept the burden of treatments where they perceived minimal benefit. This study describes the substantial treatment burden experienced by patients with COPD. Medical advice may be rejected by patients if the benefit of following the advice is perceived as insufficient. Health professionals need to recognize treatment burden as a source of nonadherence, and should tailor treatment discussions to fit patients' values and capacity to achieve optimal patient outcomes.

  7. The Lung Microbiome in Moderate and Severe Chronic Obstructive Pulmonary Disease

    PubMed Central

    Pragman, Alexa A.; Kim, Hyeun Bum; Reilly, Cavan S.; Wendt, Christine; Isaacson, Richard E.

    2012-01-01

    Chronic obstructive pulmonary disease (COPD) is an inflammatory disorder characterized by incompletely reversible airflow obstruction. Bacterial infection of the lower respiratory tract contributes to approximately 50% of COPD exacerbations. Even during periods of stable lung function, the lung harbors a community of bacteria, termed the microbiome. The role of the lung microbiome in the pathogenesis of COPD remains unknown. The COPD lung microbiome, like the healthy lung microbiome, appears to reflect microaspiration of oral microflora. Here we describe the COPD lung microbiome of 22 patients with Moderate or Severe COPD compared to 10 healthy control patients. The composition of the lung microbiomes was determined using 454 pyrosequencing of 16S rDNA found in bronchoalveolar lavage fluid. Sequences were analyzed using mothur, Ribosomal Database Project, Fast UniFrac, and Metastats. Our results showed a significant increase in microbial diversity with the development of COPD. The main phyla in all samples were Actinobacteria, Firmicutes, and Proteobacteria. Principal coordinate analyses demonstrated separation of control and COPD samples, but samples did not cluster based on disease severity. However, samples did cluster based on the use of inhaled corticosteroids and inhaled bronchodilators. Metastats analyses demonstrated an increased abundance of several oral bacteria in COPD samples. PMID:23071781

  8. Reliability of FEV1/FEV6 to Diagnose Airflow Obstruction Compared with FEV1/FVC: The PLATINO Longitudinal Study

    PubMed Central

    Perez-Padilla, Rogelio; Wehrmeister, Fernando C.; Celli, Bartolome R.; Lopez-Varela, Maria Victorina; Montes de Oca, Maria; Muiño, Adriana; Talamo, Carlos; Jardim, Jose R.; Valdivia, Gonzalo; Lisboa, Carmen; Menezes, Ana Maria B.

    2013-01-01

    QUESTION A 6-second spirometry test is easier than full exhalations. We compared the reliability of the ratio of the Forced expiratory volume in 1 second/Forced expiratory volume in 6 seconds (FEV1/FEV6) to the ratio of the FEV1/Forced vital capacity (FEV1/FVC) for the detection of airway obstruction. METHODS The PLATINO population-based survey in individuals aged 40 years and over designed to estimate the prevalence of post-Bronchodilator airway obstruction repeated for the same study participants after 5–9 years in three Latin-American cities. RESULTS Using the FEV1/FVCobstruction, the changes in prevalence were smaller: 9.7 to 10.6% in Montevideo, 8.6 to 9.0% in São Paulo, and 7.5 to 7.9% in Santiago. Changes in the prevalence of COPD with criteria based on FEV1/FVC correlated strongly with changes in the FET of the tests (R2 0.92) unlike the prevalence based on a low FEV1/FEV6 (R2 = 0.40). CONCLUSION The FEV1/FEV6 is a more reliable index than FEV1/FVC because FVC varies with the duration of the forced exhalation. Reporting FET and FEV1/FEV6

  9. Genetic analysis of candidate SNPs for metabolic syndrome in obstructive sleep apnea (OSA)

    PubMed Central

    Grilo, Antonio; Ruiz-Granados, Elena S.; Moreno-Rey, Concha; Rivera, Jose M.; Ruiz, Agustin; Real, Luis M.; Sáez, Maria E.

    2014-01-01

    Obstructive sleep apnea (OSA) is a common disorder characterized by the reduction or complete cessation in airflow resulting from an obstruction of the upper airway. Several studies have observed an increased risk for cardiovascular morbidity and mortality among OSA patients. Metabolic syndrome (MetS), a cluster of cardiovascular risk factors characterized by the presence of insulin resistance, is often found in patients with OSA, but the complex interplay between these two syndromes is not well understood. In this study, we present the results of a genetic association analysis of 373 candidate SNPs for MetS selected in a previous genome wide association analysis (GWAS). The 384 selected SNPs were genotyped using the Illumina VeraCode Technology in 387 subjects retrospectively assessed at the Internal Medicine Unit of the “Virgen de Valme” University Hospital (Seville, Spain). In order to increase the power of this study and to validate our findings in an independent population, we used data from the Framingham Sleep study which comprises 368 individuals. Only the rs11211631 polymorphism was associated with OSA in both populations, with an estimated OR=0.57 (0.42-0.79) in the joint analysis (p=7.21 × 10-4). This SNP was selected in the previous GWAS for MetS components using a digenic approach, but was not significant in the monogenic study. We have also identified two SNPs (rs2687855 and rs4299396) with a protective effect from OSA only in the abdominal obese subpopulation. As a whole, our study does not support that OSA and MetS share major genetic determinants, although both syndromes share common epidemiological and clinical features. PMID:23524009

  10. Preclinical murine models of Chronic Obstructive Pulmonary Disease.

    PubMed

    Vlahos, Ross; Bozinovski, Steven

    2015-07-15

    Chronic Obstructive Pulmonary Disease (COPD) is a major incurable global health burden and is the 4th leading cause of death worldwide. It is believed that an exaggerated inflammatory response to cigarette smoke causes progressive airflow limitation. This inflammation, where macrophages, neutrophils and T lymphocytes are prominent, leads to oxidative stress, emphysema, small airway fibrosis and mucus hypersecretion. Much of the disease burden and health care utilisation in COPD is associated with the management of its comorbidities and infectious (viral and bacterial) exacerbations (AECOPD). Comorbidities, defined as other chronic medical conditions, in particular skeletal muscle wasting and cardiovascular disease markedly impact on disease morbidity, progression and mortality. The mechanisms and mediators underlying COPD and its comorbidities are poorly understood and current COPD therapy is relatively ineffective. Thus, there is an obvious need for new therapies that can prevent the induction and progression of COPD and effectively treat AECOPD and comorbidities of COPD. Given that access to COPD patients can be difficult and that clinical samples often represent a "snapshot" at a particular time in the disease process, many researchers have used animal modelling systems to explore the mechanisms underlying COPD, AECOPD and comorbidities of COPD with the goal of identifying novel therapeutic targets. This review highlights the mouse models used to define the cellular, molecular and pathological consequences of cigarette smoke exposure and the recent advances in modelling infectious exacerbations and comorbidities of COPD. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Response of Metal Core Piezoelectric Fibers to Unsteady Airflows

    NASA Astrophysics Data System (ADS)

    Qiu, J. H.; Ji, H. L.; Zhu, K. J.; Park, M. J.

    In the previous study, possible applications of metal core piezoelectric fibers with a diameter of 200 to 250 µm as bionic airflow sensors mimicking the flow sensitive receptor hairs of crickets have been proposed. This study aims to investigate the dynamic responses of the metal core piezoelectric fibers to unsteady airflow. The metal core piezoelectric fiber is half coated on the outer surface and is used in the bending mode. Wind tunnel tests were carried out and the output voltage of the fiber under the excitation of the unsteady aerodynamic force during flow acceleration and deceleration was measured when the wind tunnel was suddenly closed or opened by a shutter. The relationship between the maximum voltage and the steady-state velocity and that between the voltage and the acceleration of flow were also obtained.

  12. Reduced Expiratory Flow Rate among Heavy Smokers Increases Lung Cancer Risk. Results from the National Lung Screening Trial–American College of Radiology Imaging Network Cohort

    PubMed Central

    Hopkins, Raewyn J.; Duan, Fenghai; Chiles, Caroline; Greco, Erin M.; Gamble, Greg D.; Aberle, Denise

    2017-01-01

    Rationale: Although epidemiological studies consistently show that chronic obstructive pulmonary disease is associated with an increased risk of lung cancer, debate exists as to whether there is a linear relationship between the severity of airflow limitation and lung cancer risk. Objectives: We examined this in a large, prospective study of older heavy smokers from the American College of Radiology Imaging Network subcohort of the National Lung Screening Trial (ACRIN). Airflow limitation was defined by prebronchodilator spirometry subgrouped according to Global Initiative for Chronic Obstructive Lung Disease (GOLD) grades 1–4. Methods: In the National Lung Screening Trial–ACRIN cohort of 18,473 screening participants, 6,436 had airflow limitation (35%) and 12,037 (65%) had no airflow limitation. From these groups, 758 lung cancer cases were prospectively identified. Participants with airflow limitation were stratified according to GOLD groups 1 (n = 1,607), 2 (n = 3,528), 3 (n = 1,083), and 4 (n = 211). Lung cancer incidence at study end (mean follow-up, 6.4 yr) was compared between the GOLD groups and those with no airflow limitation (referent group). Measurements and Main Results: Compared with those with no airflow limitation, where lung cancer incidence was 3.78/1,000 person years, incidence rates increased in a simple linear relationship: GOLD 1 (6.27/1,000 person yr); GOLD 2 (7.86/1,000 person yr); GOLD 3 (10.71/1,000 person yr); and GOLD 4 (13.25/1,000 person yr). All relationships were significant versus the reference group at a P value of 0.0001 or less. Conclusions: In a large prospective study of high-risk cigarette smokers, we report a strong linear relationship between increasing severity of airflow limitation and risk of lung cancer. PMID:28076701

  13. Reduced Expiratory Flow Rate among Heavy Smokers Increases Lung Cancer Risk. Results from the National Lung Screening Trial-American College of Radiology Imaging Network Cohort.

    PubMed

    Hopkins, Raewyn J; Duan, Fenghai; Chiles, Caroline; Greco, Erin M; Gamble, Greg D; Aberle, Denise; Young, Robert P

    2017-03-01

    Although epidemiological studies consistently show that chronic obstructive pulmonary disease is associated with an increased risk of lung cancer, debate exists as to whether there is a linear relationship between the severity of airflow limitation and lung cancer risk. We examined this in a large, prospective study of older heavy smokers from the American College of Radiology Imaging Network subcohort of the National Lung Screening Trial (ACRIN). Airflow limitation was defined by prebronchodilator spirometry subgrouped according to Global Initiative for Chronic Obstructive Lung Disease (GOLD) grades 1-4. In the National Lung Screening Trial-ACRIN cohort of 18,473 screening participants, 6,436 had airflow limitation (35%) and 12,037 (65%) had no airflow limitation. From these groups, 758 lung cancer cases were prospectively identified. Participants with airflow limitation were stratified according to GOLD groups 1 (n = 1,607), 2 (n = 3,528), 3 (n = 1,083), and 4 (n = 211). Lung cancer incidence at study end (mean follow-up, 6.4 yr) was compared between the GOLD groups and those with no airflow limitation (referent group). Compared with those with no airflow limitation, where lung cancer incidence was 3.78/1,000 person years, incidence rates increased in a simple linear relationship: GOLD 1 (6.27/1,000 person yr); GOLD 2 (7.86/1,000 person yr); GOLD 3 (10.71/1,000 person yr); and GOLD 4 (13.25/1,000 person yr). All relationships were significant versus the reference group at a P value of 0.0001 or less. In a large prospective study of high-risk cigarette smokers, we report a strong linear relationship between increasing severity of airflow limitation and risk of lung cancer.

  14. Characteristics of stable chronic obstructive pulmonary disease patients in the pulmonology clinics of seven Asian cities

    PubMed Central

    Oh, Yeon-Mok; Bhome, Arvind B; Boonsawat, Watchara; Gunasekera, Kirthi Dias; Madegedara, Dushantha; Idolor, Luisito; Roa, Camilo; Kim, Woo Jin; Kuo, Han-Pin; Wang, Chun-Hua; Lan, Le Thi Tuyet; Loh, Li-Cher; Ong, Choo-Khoon; Ng, Alan; Nishimura, Masaharu; Makita, Hironi; Silverman, Edwin K; Lee, Jae Seung; Yang, Ting; Lin, Yingxiang; Wang, Chen; Lee, Sang-Do

    2013-01-01

    Background and objectives Chronic obstructive pulmonary disease (COPD) is responsible for significant morbidity and mortality worldwide. We evaluated the characteristics of stable COPD patients in the pulmonology clinics of seven Asian cities and also evaluated whether the exposure to biomass fuels and dusty jobs were related to respiratory symptoms, airflow limitation, and quality of life in the COPD patients. Methods This cross-sectional observational study recruited 922 COPD patients from seven cities of Asia. The patients underwent spirometry and were administered questionnaires about their exposure to cigarette smoking, biomass fuels, and dusty jobs in addition to respiratory symptoms and health related quality of life. Results Of the patients, there appeared to be variations from city to city in the history of exposure to biomass fuels and dusty jobs and also in respiratory symptoms of cough, phlegm, wheeze, and dyspnea. These symptoms were more frequent in those COPD patients with a history of exposure to biomass fuels than without and those with a history of exposure to dusty jobs than without (P < 0.01 for all comparisons). Airflow limitation was more severe in those COPD patients with a history of exposure to biomass fuels than without (52.2% predicted versus 55.9% of post-bronchodilator forced expiratory volume in 1 second [FEV1], P = 0.009); quality of life was poorer in those with exposure to biomass fuels than without (40.4 versus 36.2 of the St George’s Respiratory Questionnaire [SGRQ] total score, P = 0.001). Airflow limitation was more severe in those COPD patients with a history of exposure to dusty jobs than without (51.2% predicted versus 57.3% of post-bronchodilator FEV1, P < 0.001); quality of life was poorer in those with dusty jobs than without (41.0 versus 34.6 of SGRQ score, P = 0.006). Conclusion In Asian cities, the characteristics of COPD patients vary and the history of exposure to biomass fuels or dusty jobs was related to frequency

  15. Characteristics of stable chronic obstructive pulmonary disease patients in the pulmonology clinics of seven Asian cities.

    PubMed

    Oh, Yeon-Mok; Bhome, Arvind B; Boonsawat, Watchara; Gunasekera, Kirthi Dias; Madegedara, Dushantha; Idolor, Luisito; Roa, Camilo; Kim, Woo Jin; Kuo, Han-Pin; Wang, Chun-Hua; Lan, Le Thi Tuyet; Loh, Li-Cher; Ong, Choo-Khoon; Ng, Alan; Nishimura, Masaharu; Makita, Hironi; Silverman, Edwin K; Lee, Jae Seung; Yang, Ting; Lin, Yingxiang; Wang, Chen; Lee, Sang-Do

    2013-01-01

    Chronic obstructive pulmonary disease (COPD) is responsible for significant morbidity and mortality worldwide. We evaluated the characteristics of stable COPD patients in the pulmonology clinics of seven Asian cities and also evaluated whether the exposure to biomass fuels and dusty jobs were related to respiratory symptoms, airflow limitation, and quality of life in the COPD patients. This cross-sectional observational study recruited 922 COPD patients from seven cities of Asia. The patients underwent spirometry and were administered questionnaires about their exposure to cigarette smoking, biomass fuels, and dusty jobs in addition to respiratory symptoms and health related quality of life. Of the patients, there appeared to be variations from city to city in the history of exposure to biomass fuels and dusty jobs and also in respiratory symptoms of cough, phlegm, wheeze, and dyspnea. These symptoms were more frequent in those COPD patients with a history of exposure to biomass fuels than without and those with a history of exposure to dusty jobs than without (P < 0.01 for all comparisons). Airflow limitation was more severe in those COPD patients with a history of exposure to biomass fuels than without (52.2% predicted versus 55.9% of post-bronchodilator forced expiratory volume in 1 second [FEV(1)], P = 0.009); quality of life was poorer in those with exposure to biomass fuels than without (40.4 versus 36.2 of the St George's Respiratory Questionnaire [SGRQ] total score, P = 0.001). Airflow limitation was more severe in those COPD patients with a history of exposure to dusty jobs than without (51.2% predicted versus 57.3% of post-bronchodilator FEV(1), P < 0.001); quality of life was poorer in those with dusty jobs than without (41.0 versus 34.6 of SGRQ score, P = 0.006). In Asian cities, the characteristics of COPD patients vary and the history of exposure to biomass fuels or dusty jobs was related to frequency of symptoms, severe airflow limitation, and poor

  16. Investigation of nanosecond pulsed dielectric barrier discharge using plate-to-plate electrode with asymmetric dielectric arrangement in airflow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qi, Haicheng; School of Physics Science and Technology, Anshan Normal University, Anshan 114005; Fan, Zhihui

    Atmospheric pressure dielectric barrier discharge plasma is produced in airflow by applying nanosecond high voltage pulses with peak voltage about 35 kV and rising time about 40 ns on a plate-to-plate electrode arrangement. The effects of airflow rate (0–50 m/s) on the discharge characteristics are investigated under different barrier conditions (the bare anode case and the bare cathode case). For both cases, the breakdown voltage and the time lag increase distinctly and the discharge intensity decreases sharply when the airflow rate increases from 0 to 30 m/s, and then keep almost constant until the airflow rate is further increased to 50 m/s. For the baremore » anode case (the cathode is covered by dielectric plate), the discharge mode transforms gradually from filamentary to diffuse discharge with the increasing airflow rate. While for the bare cathode case, some micro-discharge channels are still excited, though the discharge becomes more diffuse when the airflow rate is higher than 30 m/s. By acquiring the time-resolved images of the discharge, it is proved that it is the primary discharge which becomes diffuse when airflow is introduced and the following two discharges of the same voltage pulse occur principally at the positions where the primary discharge is more intense. And in both cases, the plasma temperatures are reduced, but the degree is different. All the phenomena can be explained mainly by the variation of the space charge distribution when the airflow is introduced into the discharge gap. And it is indicated that the bare anode case has an advantage in obtaining diffuse discharge.« less

  17. COMIS -- an international multizone air-flow and contaminant transport model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feustel, H.E.

    1998-08-01

    A number of interzonal models have been developed to calculate air flows and pollutant transport mechanisms in both single and multizone buildings. A recent development in multizone air-flow modeling, the COMIS model, has a number of capabilities that go beyond previous models, much as COMIS can be used as either a stand-alone air-flow model with input and output features or as an infiltration module for thermal building simulation programs. COMIS was designed during a 12 month workshop at Lawrence Berkeley National Laboratory (LBNL) in 1988-89. In 1990, the Executive Committee of the International Energy Agency`s Energy Conservation in Buildings andmore » Community Systems program created a working group on multizone air-flow modeling, which continued work on COMIS. The group`s objectives were to study physical phenomena causing air flow and pollutant (e.g., moisture) transport in multizone buildings, develop numerical modules to be integrated in the previously designed multizone air flow modeling system, and evaluate the computer code. The working group supported by nine nations, officially finished in late 1997 with the release of IISiBat/COMIS 3.0, which contains the documented simulation program COMIS, the user interface IISiBat, and reports describing the evaluation exercise.« less

  18. Preliminary investigation on the effects of primary airflow to coal particle distribution in coal-fired boilers

    NASA Astrophysics Data System (ADS)

    Noor, N. A. W. Mohd; Hassan, H.; Hashim, M. F.; Hasini, H.; Munisamy, K. M.

    2017-04-01

    This paper presents an investigation on the effects of primary airflow to coal fineness in coal-fired boilers. In coal fired power plant, coal is pulverized in a pulverizer, and it is then transferred to boiler for combustion. Coal need to be ground to its desired size to obtain maximum combustion efficiency. Coarse coal particle size may lead to many performance problems such as formation of clinker. In this study, the effects of primary airflow to coal particles size and coal flow distribution were investigated by using isokinetic coal sampling and computational fluid dynamic (CFD) modelling. Four different primary airflows were tested and the effects to resulting coal fineness were recorded. Results show that the optimum coal fineness distribution is obtained at design primary airflow. Any reduction or increase of air flow rate results in undesirable coal fineness distribution.

  19. High frequency chest wall compression and carbon dioxide elimination in obstructed dogs.

    PubMed

    Gross, D; Vartian, V; Minami, H; Chang, H K; Zidulka, A

    1984-01-01

    High frequency chest wall compression (HFCWC) was studied as a method of assisting ventilation in six spontaneously breathing anesthetized dogs. Under a constant level of anesthesia, the dogs became hypercapneic after airflow obstruction was created by metal beads inserted in the airways. HFCWC was achieved by a piston pump rapidly oscillating the pressure in a modified double blood pressure cuff wrapped around the lower thorax. Thirty minute periods of spontaneous ventilation were alternated with thirty minute periods of spontaneous breathing plus HFCWC at 3, 5 or 8 Hz. The superimposition of HFCWC to spontaneous ventilation resulted in little change in the PaO2. The PaCO2, however, was reduced in every case from a mean of 6.55 +/- 0.59 to 4.72 +/- 0.32 kPa at 3 Hz (p less than 0.05), 6.92 +/- 0.57 to 3.9 +/- 0.45 kPa at 5 Hz (p less than 0.01) and 7.10 +/- 0.65 to 4.56 +/- 0.59 kPa at 8 Hz (p less than 0.05). This occurred despite a decrease in spontaneous minute ventilation. We conclude that HFCWC can assist in elimination of CO2 in obstructed spontaneous breathing dogs with hypercapnea.

  20. The Effect of Defining Chronic Obstructive Pulmonary Disease by the Lower Limit of Normal of FEV1/FVC Ratio in Tiotropium Safety and Performance in Respimat Participants.

    PubMed

    Calverley, Peter M A; Mueller, Achim; Fowler, Andrew; Metzdorf, Norbert; Wise, Robert A

    2018-02-01

    There is continuing debate about whether to define airflow obstruction by a post-bronchodilator ratio of forced expiratory volume in 1 second (FEV 1 ) and forced vital capacity (FVC) below 0.70, or by ratio values falling below the age-dependent lower limit of normal (LLN) derived from general population data. To determine whether using the LLN criterion affects the classification and outcomes of patients previously defined as having chronic obstructive pulmonary disease by the fixed FEV 1 /FVC ratio. We applied the LLN definition to pooled data from the Tiotropium Safety and Performance in Respimat study that used the fixed FEV 1 /FVC ratio for the clinical diagnosis of chronic obstructive pulmonary disease. A total of 17,072 patients were analyzed; of these, 1,807 (10.6%) patients had a ratio greater than or equal to LLN. Patients with a ratio greater than or equal to LLN had similar risks of death from any cause and fatal major adverse cardiovascular (CV) event as those below LLN. Patients with a ratio below LLN had a significantly lower risk of major adverse CV events (hazard ratio = 0.69; 95% confidence interval [CI] = 0.55-0.86; P = 0.001), and had significantly greater risks of moderate to severe exacerbation (rate ratio = 1.48; 95% CI = 1.36-1.61; P < 0.0001) and severe exacerbation (rate ratio = 2.01; 95% CI = 1.68-2.40; P < 0.0001) when compared with patients greater than or equal to LLN. Study outcomes by treatment arm (5 μg tiotropium Respimat vs. 18 μg HandiHaler) were comparable. Using the LLN to define airflow obstruction would have excluded patients in the Tiotropium Safety and Performance in Respimat study with a higher risk of nonfatal major adverse CV events and a lower risk of exacerbation; study outcomes by treatment arm (2.5 μg/5 μg tiotropium Respimat vs. 18 μg HandiHaler) remained similar. Clinical trial registered with www.clinicaltrials.gov (NCT01126437).

  1. Risk factors for persistent airflow limitation: Analysis of 306 patients with asthma.

    PubMed

    Wang, Lingcheng; Gao, Shuncui; Zhu, Wei; Su, Jun

    2014-01-01

    Objectives : To determine the risk factors associated with persistent airflow limitation in patients with asthma. Method s: This study was designed and carried out in the department of respiratory medicine, fourth People's Hospital of Jinan City, Shandong province, China between Jan 2012 and Dec 2012. Three hundred and six asthma patients participating in the study were divided into persistent airflow limitation group (PAFL) and no persistent airflow limitation group (NPAFL). The patients participated in pulmonary function tests and sputum induction examination. The clinical data including age, gender, onset age, disease course, smoking history, family history, regular corticosteroid inhalation, hospitalization history and presence of atopy were collected. Results : In 306 patients, 128 (40.5%) were included in PAFL group and 178(59.5%) in NPAFL group. Multivariate analysis demonstrated smoking (≥10 pack-years; OR, 7.1; 95% CI, 1.8 to 31.2), longer asthma duration (≥ 20years) (OR, 6.3; 95% CI, 1.7 to 28.5), absence of regular corticosteroid inhalation (OR, 3.5; 95% CI, 1.1 to 14.5) and neutrophil in induced sputum≥65% (OR, 1.8; 95% CI, 1.0 to 2.8) were independent risk factors for PAFL. Conclusions : Smoking, longer asthma duration and increased neutrophil in induced sputum are risk factors for PAFL, while regular corticosteroid inhalation is protective factor. Smoking cessation and regular corticosteroid inhalation may play an important role in preventing the occurrence of persistent airflow limitation group (PAFL).

  2. Majority of never-smokers with airflow limitation do not have asthma: the Copenhagen General Population Study.

    PubMed

    Çolak, Yunus; Afzal, Shoaib; Nordestgaard, Børge G; Lange, Peter

    2016-07-01

    A substantial proportion of individuals with airflow limitation are never-smokers. However, whether never-smokers with airflow limitation have undiagnosed asthma is unknown. We hypothesised that the majority of never-smokers with respiratory symptoms and airflow limitation but without known asthma have undiagnosed asthma by comparing characteristics and prognosis in never-smokers with airflow limitation and asthma (NS+AFL+A) with never-smokers with airflow limitation but without asthma (NS+AFL-A). Among 94 079 participants aged 20-100 years from the general population, 39 102 (42%) were never-smokers. In this group, 13 719 (35%) reported to have respiratory symptoms of whom 1610 (12%) had airflow limitation. We investigated characteristics and risk of complications (asthma or COPD exacerbations, pneumonias and all-cause mortality) and comorbidities (lung cancer, ischaemic heart disease, myocardial infarction, deep venous thrombosis and PE) during 4.5 years median follow-up. NS+AFL-A compared with NS+AFL+A reported less allergy and respiratory symptoms, and had higher FEV1 and lower levels of eosinophils and IgE in peripheral blood. NS+AFL+A had increased risk of asthma and COPD exacerbations, but not of pneumonias; adjusted HRs in NS+AFL+A compared with NS+AFL-A were 16 (95% CI 3.7 to 73) for asthma exacerbations and 15 (2.8 to 80) for COPD exacerbations. Still, NS+AFL-A had increased risk of COPD exacerbations and pneumonias, but not of asthma exacerbations; adjusted HRs in NS+AFL-A compared with never-smokers without airflow limitation or asthma (NS-AFL-A) were 7.7 (2.8 to 21) for COPD exacerbations and 1.7 (1.3 to 2.3) for pneumonias. Risk of comorbidities or all-cause mortality was not increased in NS+AFL-A or NS+AFL+A compared with NS-AFL-A. Majority of NS+AFL-A do not seem to have undiagnosed asthma and may instead have airflow limitation caused by other risk factors. Published by the BMJ Publishing Group Limited. For permission to use (where not

  3. Case-finding of chronic obstructive pulmonary disease with questionnaire, peak flow measurements and spirometry: a cross-sectional study

    PubMed Central

    2014-01-01

    Background Spirometry is commonly accepted as the gold standard for the diagnosis of COPD, but the reality remains that quality assured spirometry is not or cannot be provided universally around the globe. Adding PEF measurement to a screening questionnaire may rule out airflow limitation compatible with COPD rationalizing spirometry testing. Methods We conducted a cross-sectional survey in a sample of individuals 40–80 yrs. old in Dubai, UAE. They were invited to answer a short socio-demographic questionnaire including a report on current, past history of smoking, and had PEF measured, then they conducted spirometry to identify airflow limitation compatible with COPD. Results Overall, 525 (91.0%) participants performed PEF and spirometry (68% male, with a mean age of 59 years, 17% UAE Nationals), 24% reported smoking of different sorts. Overall, 68 participants (12.9%, 95% C.I. 10.3% to 16.1%) had airflow limitation compatible with COPD. PEFR alone identified 141participants with airflow limitation compatible with COPD, with specificity of 80% and sensitivity of 73.5%. Conclusions PEFR could be an easy, cheap, and non-biased tool to assist with the case-finding of COPD before confirmation with spirometry. PMID:24739210

  4. Experimental and modelling study of the effect of airflow orientation with respect to strip electrode on ozone production of surface dielectric barrier discharge

    NASA Astrophysics Data System (ADS)

    Mikeš, J.; Pekárek, S.; Soukup, I.

    2016-11-01

    This study examines the effect of airflow orientation with respect to the strip active electrode on concentration of ozone and nitrogen dioxide produced in a planar generator based on the surface dielectric barrier discharge. The orientation of the airflow was tested in parallel and perpendicular with respect to the strips. It was found that in the investigated range of average discharge power, the ozone concentration increases approximately by 25% when airflow was oriented in parallel with respect to the strips in comparison with perpendicular orientation of the airflow. Similarly the increase of nitrogen dioxide concentration was observed for parallel orientation of the airflow with respect to the strips in comparison with the perpendicular orientation of the airflow. Within the range of wavelengths from 250 to 1100 nm, the changes of intensities of spectral lines associated with airflow orientation have been observed. A 3D numerical model describing ion trajectories and airflow patterns have also been developed.

  5. A Hot-Polymer Fiber Fabry–Perot Interferometer Anemometer for Sensing Airflow

    PubMed Central

    Lee, Cheng-Ling; Liu, Kai-Wen; Luo, Shi-Hong; Wu, Meng-Shan; Ma, Chao-Tsung

    2017-01-01

    This work proposes the first hot-polymer fiber Fabry–Perot interferometer (HPFFPI) anemometer for sensing airflow. The proposed HPFFPI is based on a single-mode fiber (SMF) endface that is attached to a UV-cured polymer to form an ultracompact fiber Fabry–Perot microcavity. The proposed polymer microcavity was heated using a low-cost chip resistor with a controllable dc driving power to achieve a desired polymer’s steady-state temperature (T) that exceeds the T of the surrounding environment. The polymer is highly sensitive to variations of T with high repeatability. When the hot polymer was cooled by the measured flowing air, the wavelength fringes of its optical spectra shifted. The HPFFPI anemometers have been experimentally evaluated for different cavity lengths and heating power values. Experimental results demonstrate that the proposed HPFFPI responses well in terms of airflow measurement. A high sensitivity of 1.139 nm/(m/s) and a good resolution of 0.0088 m/s over the 0~2.54 m/s range of airflow were achieved with a cavity length of 10 μm and a heating power of 0.402 W. PMID:28869510

  6. Using cluster analysis to identify phenotypes and validation of mortality in men with COPD.

    PubMed

    Chen, Chiung-Zuei; Wang, Liang-Yi; Ou, Chih-Ying; Lee, Cheng-Hung; Lin, Chien-Chung; Hsiue, Tzuen-Ren

    2014-12-01

    Cluster analysis has been proposed to examine phenotypic heterogeneity in chronic obstructive pulmonary disease (COPD). The aim of this study was to use cluster analysis to define COPD phenotypes and validate them by assessing their relationship with mortality. Male subjects with COPD were recruited to identify and validate COPD phenotypes. Seven variables were assessed for their relevance to COPD, age, FEV(1) % predicted, BMI, history of severe exacerbations, mMRC, SpO(2), and Charlson index. COPD groups were identified by cluster analysis and validated prospectively against mortality during a 4-year follow-up. Analysis of 332 COPD subjects identified five clusters from cluster A to cluster E. Assessment of the predictive validity of these clusters of COPD showed that cluster E patients had higher all cause mortality (HR 18.3, p < 0.0001), and respiratory cause mortality (HR 21.5, p < 0.0001) than those in the other four groups. Cluster E patients also had higher all cause mortality (HR 14.3, p = 0.0002) and respiratory cause mortality (HR 10.1, p = 0.0013) than patients in cluster D alone. COPD patient with severe airflow limitation, many symptoms, and a history of frequent severe exacerbations was a novel and distinct clinical phenotype predicting mortality in men with COPD.

  7. Obstructive Sleep-Disordered Breathing Is More Common than Central in Mild Familial Dysautonomia

    PubMed Central

    Hilz, Max J.; Moeller, Sebastian; Buechner, Susanne; Czarkowska, Hanna; Ayappa, Indu; Axelrod, Felicia B.; Rapoport, David M.

    2016-01-01

    Study Objectives: In familial dysautonomia (FD) patients, sleep-disordered breathing (SDB) might contribute to their high risk of sleep-related sudden death. Prevalence of central versus obstructive sleep apneas is controversial but may be therapeutically relevant. We, therefore, assessed sleep structure and SDB in FD-patients with no history of SDB. Methods: 11 mildly affected FD-patients (28 ± 11 years) without clinically overt SDB and 13 controls (28 ± 10 years) underwent polysomnographic recording during one night. We assessed sleep stages, obstructive and central apneas (≥ 90% air flow reduction) and hypopneas (> 30% decrease in airflow with ≥ 4% oxygen-desaturation), and determined obstructive (oAI) and central (cAI) apnea indices and the hypopnea index (HI) as count of respective apneas/hypopneas divided by sleep time. We obtained the apnea-hypopnea index (AHI4%) from the total of apneas and hypopneas divided by sleep time. We determined differences between FD-patients and controls using the U-test and within-group differences between oAIs, cAIs, and HIs using the Friedman test and Wilcoxon test. Results: Sleep structure was similar in FD-patients and controls. AHI4% and HI were significantly higher in patients than controls. In patients, HIs were higher than oAIs and oAIs were higher than cAIs. In controls, there was no difference between HIs, oAIs, and cAIs. Only patients had apneas and hypopneas during slow wave sleep. Conclusions: In our FD-patients, obstructive apneas were more common than central apneas. These findings may be related to FD-specific pathophysiology. The potential ramifications of SDB in FD-patients suggest the utility of polysomnography to unveil SDB and initiate treatment. Commentary: A commentary on this article appears in this issue on page 1583. Citation: Hilz MJ, Moeller S, Buechner S, Czarkowska H, Ayappa I, Axelrod FB, Rapoport DM. Obstructive sleep-disordered breathing is more common than central in mild familial

  8. Patient-perceived treatment burden of chronic obstructive pulmonary disease

    PubMed Central

    Harb, Nathan; Foster, Juliet M; Dobler, Claudia C

    2017-01-01

    Background While chronic morbidity and mortality from COPD is well documented, little is known about the treatment burden faced by patients with COPD. Subjects and methods Patients with severe airflow obstruction (forced expiratory volume in 1 second [FEV1] <50% predicted) representing different age-groups, sex, and number of comorbidities participated in a semistructured interview. Interviews were conducted until thematic saturation was reached. Interviews were recorded, transcribed, and analyzed thematically using an established treatment-burden framework. Results A total of 26 patients (42% male, mean age 66.7±9.8 years) with severe (n=15) or very severe (n=11) airflow limitation (mean FEV1 32.1%±9.65% predicted) were interviewed. Participants struggled with various treatment-burden domains, predominantly with changing health behaviors, such as smoking cessation and exercise. Interviewees often only ceased smoking after a major health event, despite being advised to do so earlier by a doctor. Recommended exercise regimens, such as pulmonary rehabilitation classes, were curtailed, although some patients replaced them with light home-based exercise. Interviewees had difficulty attending medical appointments, often relying on others to transport them. Overall, COPD patients indicated they were not willing to accept the burden of treatments where they perceived minimal benefit. Conclusion This study describes the substantial treatment burden experienced by patients with COPD. Medical advice may be rejected by patients if the benefit of following the advice is perceived as insufficient. Health professionals need to recognize treatment burden as a source of nonadherence, and should tailor treatment discussions to fit patients’ values and capacity to achieve optimal patient outcomes. PMID:28615937

  9. The fluid dynamics of canine olfaction: unique nasal airflow patterns as an explanation of macrosmia

    PubMed Central

    Craven, Brent A.; Paterson, Eric G.; Settles, Gary S.

    2010-01-01

    The canine nasal cavity contains hundreds of millions of sensory neurons, located in the olfactory epithelium that lines convoluted nasal turbinates recessed in the rear of the nose. Traditional explanations for canine olfactory acuity, which include large sensory organ size and receptor gene repertoire, overlook the fluid dynamics of odorant transport during sniffing. But odorant transport to the sensory part of the nose is the first critical step in olfaction. Here we report new experimental data on canine sniffing and demonstrate allometric scaling of sniff frequency, inspiratory airflow rate and tidal volume with body mass. Next, a computational fluid dynamics simulation of airflow in an anatomically accurate three-dimensional model of the canine nasal cavity, reconstructed from high-resolution magnetic resonance imaging scans, reveals that, during sniffing, spatially separate odour samples are acquired by each nostril that may be used for bilateral stimulus intensity comparison and odour source localization. Inside the nose, the computation shows that a unique nasal airflow pattern develops during sniffing, which is optimized for odorant transport to the olfactory part of the nose. These results contrast sharply with nasal airflow in the human. We propose that mammalian olfactory function and acuity may largely depend on odorant transport by nasal airflow patterns resulting from either the presence of a highly developed olfactory recess (in macrosmats such as the canine) or the lack of one (in microsmats including humans). PMID:20007171

  10. Bayesian Modeling of Exposure and Airflow Using Two-Zone Models

    PubMed Central

    Zhang, Yufen; Banerjee, Sudipto; Yang, Rui; Lungu, Claudiu; Ramachandran, Gurumurthy

    2009-01-01

    Mathematical modeling is being increasingly used as a means for assessing occupational exposures. However, predicting exposure in real settings is constrained by lack of quantitative knowledge of exposure determinants. Validation of models in occupational settings is, therefore, a challenge. Not only do the model parameters need to be known, the models also need to predict the output with some degree of accuracy. In this paper, a Bayesian statistical framework is used for estimating model parameters and exposure concentrations for a two-zone model. The model predicts concentrations in a zone near the source and far away from the source as functions of the toluene generation rate, air ventilation rate through the chamber, and the airflow between near and far fields. The framework combines prior or expert information on the physical model along with the observed data. The framework is applied to simulated data as well as data obtained from the experiments conducted in a chamber. Toluene vapors are generated from a source under different conditions of airflow direction, the presence of a mannequin, and simulated body heat of the mannequin. The Bayesian framework accounts for uncertainty in measurement as well as in the unknown rate of airflow between the near and far fields. The results show that estimates of the interzonal airflow are always close to the estimated equilibrium solutions, which implies that the method works efficiently. The predictions of near-field concentration for both the simulated and real data show nice concordance with the true values, indicating that the two-zone model assumptions agree with the reality to a large extent and the model is suitable for predicting the contaminant concentration. Comparison of the estimated model and its margin of error with the experimental data thus enables validation of the physical model assumptions. The approach illustrates how exposure models and information on model parameters together with the knowledge of

  11. The PLATINO study: description of the distribution, stability, and mortality according to the Global Initiative for Chronic Obstructive Lung Disease classification from 2007 to 2017.

    PubMed

    Menezes, Ana M; Wehrmeister, Fernando C; Perez-Padilla, Rogelio; Viana, Karynna P; Soares, Claudia; Müllerova, Hana; Valdivia, Gonzalo; Jardim, José R; Montes de Oca, Maria

    2017-01-01

    The Global Initiative for Chronic Obstructive Lung Disease (GOLD) report provides a framework for classifying COPD reflecting the impacts of disease on patients and for targeting treatment recommendations. The GOLD 2017 introduced a new classification with 16 subgroups based on a composite of spirometry and symptoms/exacerbations. Data from the population-based PLATINO study, collected at baseline and at follow-up, in three sites in Latin America were analyzed to compare the following: 1) the distribution of COPD patients according to GOLD 2007, 2013, and 2017; 2) the stability of the 2007 and 2013 classifications; and 3) the mortality rate over time stratified by GOLD 2007, 2013, and 2017. Of the 524 COPD patients evaluated, most of them were classified as Grade I or II (GOLD 2007) and Group A or B (GOLD 2013), with ≈70% of those classified as Group A in GOLD 2013 also classified as Grade I in GOLD 2007 and the highest percentage (41%) in Group D (2013) classified as Grade III (2007). According to GOLD 2017, among patients with Grade I airflow limitation, 69% of them were categorized into Group A, whereas Grade IV patients were more evenly distributed among Groups A-D. Most of the patients classified by GOLD 2007 remained in the same airflow limitation group at the follow-up; a greater temporal variability was observed with GOLD 2013 classification. Incidence-mortality rate in patients classified by GOLD 2007 was positively associated with increasing severity of airflow obstruction; for GOLD 2013 and GOLD 2017 (Groups A-D), highest mortality rates were observed in Groups C and D. No clear pattern was observed for mortality across the GOLD 2017 subgroups. The PLATINO study data suggest that GOLD 2007 classification shows more stability over time compared with GOLD 2013. No clear patterns with respect to the distribution of patients or incidence-mortality rates were observed according to GOLD 2013/2017 classification.

  12. Fabrication of highly oriented nanoporous fibers via airflow bubble-spinning

    NASA Astrophysics Data System (ADS)

    Liu, Fujuan; Li, Shaokai; Fang, Yue; Zheng, Fangfang; Li, Junhua; He, Jihuan

    2017-11-01

    Highly oriented Poly(lactic acid) (PLA) nanofibers with nanoporous structures has been successfully fabricated via airflow bubble-spinning without electrostatic hazard. In this work, the volatile solvent was necessary for preparing the nanoporous fiber, which was attributed to the competition between phase separation and solvent evaporation. The interconnected porous structures were affected by the processing variables of solution concentration, airflow temperature, collecting distance and relative humidity (RH). Besides, the rheological properties of solutions were studied and the highly oriented PLA nanofibers with nanoporous structure were also completely characterized using scanning electron microscope (SEM). This study provided a novel technique that successfully gets rid of the potential safety hazards caused by unexpected static to prepare highly oriented nanoporous fibers, which would demonstrate an impressive prospect for the fields of adsorption and filtration.

  13. Fuel composition effect on cathode airflow control in fuel cell gas turbine hybrid systems

    NASA Astrophysics Data System (ADS)

    Zhou, Nana; Zaccaria, Valentina; Tucker, David

    2018-04-01

    Cathode airflow regulation is considered an effective means for thermal management in solid oxide fuel cell gas turbine (SOFC-GT) hybrid system. However, performance and controllability are observed to vary significantly with different fuel compositions. Because a complete system characterization with any possible fuel composition is not feasible, the need arises for robust controllers. The sufficiency of robust control is dictated by the effective change of operating state given the new composition used. It is possible that controller response could become unstable without a change in the gains from one state to the other. In this paper, cathode airflow transients are analyzed in a SOFC-GT system using syngas as fuel composition, comparing with previous work which used humidified hydrogen. Transfer functions are developed to map the relationship between the airflow bypass and several key variables. The impact of fuel composition on system control is quantified by evaluating the difference between gains and poles in transfer functions. Significant variations in the gains and the poles, more than 20% in most cases, are found in turbine rotational speed and cathode airflow. The results of this work provide a guideline for the development of future control strategies to face fuel composition changes.

  14. Elevated intrabolus pressure identifies obstructive processes when integrated relaxation pressure is normal on esophageal high-resolution manometry.

    PubMed

    Quader, Farhan; Reddy, Chanakyaram; Patel, Amit; Gyawali, C Prakash

    2017-07-01

    Elevated integrated relaxation pressure (IRP) on esophageal high-resolution manometry (HRM) identifies obstructive processes at the esophagogastric junction (EGJ). Our aim was to determine whether intrabolus pressure (IBP) can identify structural EGJ processes when IRP is normal. In this observational cohort study, adult patients with dysphagia and undergoing HRM were evaluated for endoscopic evidence of structural EGJ processes (strictures, rings, hiatus hernia) in the setting of normal IRP. HRM metrics [IRP, distal contractile integral (DCI), distal latency (DL), IBP, and EGJ contractile integral (EGJ-CI)] were compared among 74 patients with structural EGJ findings (62.8 ± 1.6 yr, 67.6% women), 27 patients with normal EGD (52.9 ± 3.2 yr, 70.3% women), and 21 healthy controls (27.6 ± 0.6 yr, 52.4% women). Findings were validated in 85 consecutive symptomatic patients to address clinical utility. In the primary cohort, mean IBP (18.4 ± 0.9 mmHg) was higher with structural EGJ findings compared with dysphagia with normal EGD (13.5 ± 1.1 mmHg, P = 0.002) and healthy controls (10.9 ± 0.9 mmHg, P < 0.001). However, mean IRP, DCI, DL, and EGJ-CI were similar across groups ( P > 0.05 for each comparison). During multiple rapid swallows, IBP remained higher in the structural findings group compared with controls ( P = 0.02). Similar analysis of the prospective validation cohort confirmed IBP elevation in structural EGJ processes, but correlation with dysphagia could not be demonstrated. We conclude that elevated IBP predicts the presence of structural EGJ processes even when IRP is normal, but correlation with dysphagia is suboptimal. NEW & NOTEWORTHY Integrated relaxation pressure (IRP) above the upper limit of normal defines esophageal outflow obstruction using high-resolution manometry. In patients with normal IRP, elevated intrabolus pressure (IBP) can be a surrogate marker for a structural restrictive or obstructive process at the

  15. Cross-Sectional Analysis of the Utility of Pulmonary Function Tests in Predicting Emphysema in Ever-Smokers

    PubMed Central

    Hesselbacher, Sean E.; Ross, Robert; Schabath, Matthew B.; Smith, E. O’Brian; Perusich, Sarah; Barrow, Nadia; Smithwick, Pamela; Mammen, Manoj J.; Coxson, Harvey; Krowchuk, Natasha; Corry, David B.; Kheradmand, Farrah

    2011-01-01

    Emphysema is largely an under-diagnosed medical condition that can exist in smokers in the absence of airway obstruction. We aimed to determine the sensitivity and specificity of pulmonary function tests (PFTs) in assessing emphysema using quantitative CT scans as the reference standard. We enrolled 224 ever-smokers (current or former) over the age of 40. CT of thorax was used to quantify the low attenuation area (% emphysema), and to measure the standardized airway wall thickness. PFTs were used individually and in combination to predict their ability to discriminate radiographic emphysema. Significant emphysema (>7%) was detected in 122 (54%) subjects. Twenty six (21%) emphysema subjects had no evidence of airflow obstruction (FEV1/FVC ratio <70%), while all subjects with >23% emphysema showed airflow obstruction. The sensitivity and specificity of spirometry for detecting radiographic emphysema were 79% and 75%, respectively. Standardized airway wall thickness was increased in subjects with airflow obstruction, but did not correlate with emphysema severity. In this cohort of lifetime ever-smokers, PFTs alone were inadequate for diagnosing emphysema. Airway wall thickness quantified by CT morphometry was associated with airflow limitation, but not with emphysema indicating that the heterogeneous nature of lung disease in smokers may represent distinct phenotypes. PMID:21655122

  16. Fine-scale flight strategies of gulls in urban airflows indicate risk and reward in city living

    PubMed Central

    Shepard, Emily L. C.

    2016-01-01

    Birds modulate their flight paths in relation to regional and global airflows in order to reduce their travel costs. Birds should also respond to fine-scale airflows, although the incidence and value of this remains largely unknown. We resolved the three-dimensional trajectories of gulls flying along a built-up coastline, and used computational fluid dynamic models to examine how gulls reacted to airflows around buildings. Birds systematically altered their flight trajectories with wind conditions to exploit updraughts over features as small as a row of low-rise buildings. This provides the first evidence that human activities can change patterns of space-use in flying birds by altering the profitability of the airscape. At finer scales still, gulls varied their position to select a narrow range of updraught values, rather than exploiting the strongest updraughts available, and their precise positions were consistent with a strategy to increase their velocity control in gusty conditions. Ultimately, strategies such as these could help unmanned aerial vehicles negotiate complex airflows. Overall, airflows around fine-scale features have profound implications for flight control and energy use, and consideration of this could lead to a paradigm-shift in the way ecologists view the urban environment. This article is part of the themed issue ‘Moving in a moving medium: new perspectives on flight’. PMID:27528784

  17. Airway Obstruction Among Latino Poultry Processing Workers in North Carolina

    PubMed Central

    MIRABELLI, MARIA C.; CHATTERJEE, ARJUN B.; MORA, DANA C.; ARCURY, THOMAS A.; BLOCKER, JILL N.; CHEN, HAIYING; GRZYWACZ, JOSEPH G.; MARÍN, ANTONIO J.; SCHULZ, MARK R.; QUANDT, SARA A.

    2015-01-01

    This analysis was conducted to evaluate the prevalence of airway obstruction among Latino poultry processing workers. Data were collected from 279 poultry processing workers and 222 other manual laborers via spirometry and interviewer-administered questionnaires. Participants employed in poultry processing reported the activities they perform at work. Participants with forced expiratory volume in 1 second (FEV1) or FEV1/forced expiratory volume (FVC) below the lower limits of normal were categorized as having airway obstruction. Airway obstruction was identified in 13% of poultry processing workers and 12% of the comparison population. Among poultry processing workers, the highest prevalence of airway obstruction (21%) occurred among workers deboning chickens (prevalence ratio: 1.75; 95% confidence interval: 0.97, 3.15). These findings identify variations in the prevalence of airway obstruction across categories of work activities. PMID:24965321

  18. Room airflow studies using sonic anemometry.

    PubMed

    Wasiolek, P T; Whicker, J J; Gong, H; Rodgers, J C

    1999-06-01

    To ensure prompt response by real-time air monitors to an accidental release of toxic aerosols in a workplace, safety professionals should understand airflow patterns. This understanding can be achieved with validated computational fluid dynamics (CFD) computer simulations, or with experimental techniques, such as measurements with smoke, neutrally buoyant markers, trace gases, or trace aerosol particles. As a supplementary technique to quantify airflows, the use of a state-of-the art, three-dimensional sonic anemometer was explored. This instrument allows for the precise measurements of the air-velocity vector components in the range of a few centimeters per second, which is common in many indoor work environments. Measurements of air velocities and directions at selected locations were made for the purpose of providing data for characterizing fundamental aspects of indoor air movement in two ventilated rooms and for comparison to CFD model predictions. One room was a mockup of a plutonium workroom, and the other was an actual functioning plutonium workroom. In the mockup room, air-velocity vector components were measured at 19 locations at three heights (60, 120 and 180 cm) with average velocities varying from 1.4 cm s-1 to 9.7 cm s-1. There were complex flow patterns observed with turbulence intensities from 39% up to 108%. In the plutonium workroom, measurements were made at the breathing-zone height, recording average velocities ranging from 9.9 cm s-1 to 35.5 cm s-1 with turbulence intensities from 33% to 108%.

  19. Portable Diagnostic Devices for Identifying Obstructive Sleep Apnea among Commercial Motor Vehicle Drivers: Considerations and Unanswered Questions

    PubMed Central

    Zhang, Chunbai; Berger, Mark; Malhotra, Atul; Kales, Stefanos N.

    2012-01-01

    Obstructive sleep apnea (OSA), a syndrome defined by breathing abnormalities during sleep, can lead to fatigue and excessive daytime sleepiness (EDS) with an increased risk of motor vehicle crashes. Identifying commercial motor vehicle operators with unrecognized OSA is a major public health priority. Portable monitors (PMs) are being actively marketed to trucking firms as potentially lower-cost and more accessible alternatives to the reference standard of in-laboratory polysomnography (PSG) in the diagnosis of OSA among commercial motor vehicle operators. Several factors regarding PMs remain uncertain in this unique patient population: their sensitivity and specificity; the cost-benefit ratio of the PMs versus PSG; potential barriers from human factors; and evolving technologic advancement. Human factors that alter test accuracy are a major concern among commercial drivers motivated to gain/maintain employment. Current available data using PMs as a diagnostic tool among CMV operators indicate relatively high data loss and high loss to follow-up. Loss to follow-up has also been an issue using PSG in commercial motor vehicle operators. Furthermore, PM testing and PM results interpretation protocols may have no sleep specialist oversight, and sometimes minimal physician oversight and involvement. Additional studies comparing unattended and unmonitored PMs directly against full in-laboratory PSG are needed to provide evidence for their efficacy among commercial motor vehicle operators. Citation: Zhang C; Berger M; Malhotra A; Kales SN. Portable diagnostic devices for identifying obstructive sleep apnea among commercial motor vehicle drivers: considerations and unanswered questions. SLEEP 2012;35(11):1481-1489. PMID:23115397

  20. Variability among electronic cigarettes in the pressure drop, airflow rate, and aerosol production.

    PubMed

    Williams, Monique; Talbot, Prue

    2011-12-01

    This study investigated the performance of electronic cigarettes (e-cigarettes), compared different models within a brand, compared identical copies of the same model within a brand, and examined performance using different protocols. Airflow rate required to generate aerosol, pressure drop across e-cigarettes, and aerosol density were examined using three different protocols. First 10 puff protocol: The airflow rate required to produce aerosol and aerosol density varied among brands, while pressure drop varied among brands and between the same model within a brand. Total air hole area correlated with pressure drop for some brands. Smoke-out protocol: E-cigarettes within a brand generally performed similarly when puffed to exhaustion; however, there was considerable variation between brands in pressure drop, airflow rate required to produce aerosol, and the total number of puffs produced. With this protocol, aerosol density varied significantly between puffs and gradually declined. CONSECUTIVE TRIAL PROTOCOL: Two copies of one model were subjected to 11 puffs in three consecutive trials with breaks between trials. One copy performed similarly in each trial, while the second copy of the same model produced little aerosol during the third trial. The different performance properties of the two units were attributed to the atomizers. There was significant variability between and within brands in the airflow rate required to produce aerosol, pressure drop, length of time cartridges lasted, and production of aerosol. Variation in performance properties within brands suggests a need for better quality control during e-cigarette manufacture.

  1. Do surgeons and surgical facilities disturb the clean air distribution close to a surgical patient in an orthopedic operating room with laminar airflow?

    PubMed

    Cao, Guangyu; Storås, Madeleine C A; Aganovic, Amar; Stenstad, Liv-Inger; Skogås, Jan Gunnar

    2018-05-04

    Airflow distribution in the operating room plays an important role in ensuring a clean operating microenvironment and preventing surgical site infections (SSIs) caused by airborne contaminations. The objective of this study was to characterize the airflow distribution in proximity to a patient in an orthopedic operating room. Experimental measurements were conducted in a real operating room at St. Olav's Hospital, Norway, with a laminar airflow system. Omnidirectional anemometers were used to investigate the air distribution in the operating zone, and 4 different cases were examined with a real person and a thermal manikin. This study showed that the downward airflow from the laminar airflow system varies in each case with different surgical arrangement, such as the position of the operating lamp. The results indicate that the interaction of thermal plumes from a patient and the downward laminar airflow may dominate the operating microenvironment. The airflow distribution in proximity to a patient is influenced by both the surgical facility and the presence of medical staff. A thermal manikin may be an economical and practical way to study the interaction of thermal plumes and downward laminar airflow. The provision of higher clean airflow rate in the operating microenvironment may be an effective way to prevent the development of SSIs caused by indoor airborne contamination. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  2. Transient Dynamics Simulation of Airflow in a CT-Scanned Human Airway Tree: More or Fewer Terminal Bronchi?

    PubMed Central

    Zhang, Baihua; Li, Jianhua; Yue, Yong; Qian, Wei

    2017-01-01

    Using computational fluid dynamics (CFD) method, the feasibility of simulating transient airflow in a CT-based airway tree with more than 100 outlets for a whole respiratory period is studied, and the influence of truncations of terminal bronchi on CFD characteristics is investigated. After an airway model with 122 outlets is extracted from CT images, the transient airflow is simulated. Spatial and temporal variations of flow velocity, wall pressure, and wall shear stress are presented; the flow pattern and lobar distribution of air are gotten as well. All results are compared with those of a truncated model with 22 outlets. It is found that the flow pattern shows lobar heterogeneity that the near-wall air in the trachea is inhaled into the upper lobe while the center flow enters the other lobes, and the lobar distribution of air is significantly correlated with the outlet area ratio. The truncation decreases airflow to right and left upper lobes and increases the deviation of airflow distributions between inspiration and expiration. Simulating the transient airflow in an airway tree model with 122 bronchi using CFD is feasible. The model with more terminal bronchi decreases the difference between the lobar distributions at inspiration and at expiration. PMID:29333194

  3. The Granite Mountain Atmospheric Sciences Testbed (GMAST): A Facility for Long Term Complex Terrain Airflow Studies

    NASA Astrophysics Data System (ADS)

    Zajic, D.; Pace, J. C.; Whiteman, C. D.; Hoch, S.

    2011-12-01

    This presentation describes a new facility at Dugway Proving Ground (DPG), Utah that can be used to study airflow over complex terrain, and to evaluate how airflow over a mountain barrier affects wind patterns over adjacent flatter terrain. DPG's primary mission is to conduct testing, training, and operational assessments of chemical and biological weapon systems. These operations require very precise weather forecasts. Most test operations at DPG are conducted on fairly flat test ranges having uniform surface cover, where airflow patterns are generally well-understood. However, the DPG test ranges are located alongside large, isolated mountains, most notably Granite Mountain, Camelback Mountain, and the Cedar Mountains. Airflows generated over, or influenced by, these mountains can affect wind patterns on the test ranges. The new facility, the Granite Mountain Atmospheric Sciences Testbed, or GMAST, is designed to facilitate studies of airflow interactions with topography. This facility will benefit DPG by improving understanding of how mountain airflows interact with the test range conditions. A core infrastructure of weather sensors around and on Granite Mountain has been developed including instrumented towers and remote sensors, along with automated data collection and archival systems. GMAST is expected to be in operation for a number of years and will provide a reference domain for mountain meteorology studies, with data useful for analysts, modelers and theoreticians. Visiting scientists are encouraged to collaborate with DPG personnel to utilize this valuable scientific resource and to add further equipment and scientific designs for both short-term and long-term atmospheric studies. Several of the upcoming MATERHORN (MountAin TERrain atmospHeric mOdeling and obseRvatioNs) project field tests will be conducted at DPG, giving an example of GMAST utilization and collaboration between DPG and visiting scientists.

  4. How much does nasal cavity morphology matter? Patterns and rates of olfactory airflow in phyllostomid bats

    PubMed Central

    Eiting, Thomas P.; Perot, J. Blair; Dumont, Elizabeth R.

    2015-01-01

    The morphology of the nasal cavity in mammals with a good sense of smell includes features that are thought to improve olfactory airflow, such as a dorsal conduit that delivers odours quickly to the olfactory mucosa, an enlarged olfactory recess at the back of the airway, and a clear separation of the olfactory and respiratory regions of the nose. The link between these features and having a good sense of smell has been established by functional examinations of a handful of distantly related mammalian species. In this paper, we provide the first detailed examination of olfactory airflow in a group of closely related species that nevertheless vary in their sense of smell. We study six species of phyllostomid bats that have different airway morphologies and foraging ecologies, which have been linked to differences in olfactory ability or reliance. We hypothesize that differences in morphology correlate with differences in the patterns and rates of airflow, which in turn are consistent with dietary differences. To compare species, we make qualitative and quantitative comparisons of the patterns and rates of airflow through the olfactory region during both inhalation and exhalation across the six species. Contrary to our expectations, we find no clear differences among species in either the patterns of airflow through the airway or in rates of flow through the olfactory region. By and large, olfactory airflow seems to be conserved across species, suggesting that morphological differences appear to be driven by other mechanical demands on the snout, such as breathing and feeding. Olfactory ability may depend on other aspects of the system, such as the neurobiological processing of odours that work within the existing morphology imposed by other functional demands on the nasal cavity. PMID:25520358

  5. PTEN IDENTIFIED AS IMPORTANT RISK FACTOR OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE

    PubMed Central

    Hosgood, H Dean; Menashe, Idan; He, Xingzhou; Chanock, Stephen; Lan, Qing

    2009-01-01

    Common genetic variation may play an important role in altering chronic obstructive pulmonary disease (COPD) risk. In Xuanwei, China, the COPD rate is more than twice the Chinese national average, and COPD is strongly associated with in-home coal use. To identify genetic variation that may be associated with COPD in a population with substantial in-home coal smoke exposures, we evaluated 1,261 single nucleotide polymorphisms (SNPs) in 380 candidate genes potentially relevant for cancer and other human diseases in a population-based case-control study in Xuanwei (53 cases; 107 controls). PTEN was the most significantly associated gene with COPD in a minP analysis using 20,000 permutations (P = 0.00005). SNP-based analyses found that homozygote variant carriers of PTEN rs701848 (ORTT = 0.12, 95%CI = 0.03 - 0.47) had a significant decreased risk of COPD. PTEN, or phosphatase and tensin homolog, is an important regulator of cell cycle progression and cellular survival via the AKT signaling pathway. Our exploratory analysis suggests that genetic variation in PTEN may be an important risk factor of COPD in Xuanwei. However, due to the small sample size, additional studies are needed to evaluate these associations within Xuanwei and other populations with coal smoke exposures. PMID:19625176

  6. Multi-level obstruction in obstructive sleep apnoea: prevalence, severity and predictive factors.

    PubMed

    Phua, C Q; Yeo, W X; Su, C; Mok, P K H

    2017-11-01

    To characterise multi-level obstruction in terms of prevalence, obstructive sleep apnoea severity and predictive factors, and to collect epidemiological data on upper airway morphology in obstructive sleep apnoea patients. Retrospective review of 250 obstructive sleep apnoea patients. On clinical examination, 171 patients (68.4 per cent) had multi-level obstruction, 49 (19.6 per cent) had single-level obstruction and 30 (12 per cent) showed no obstruction. Within each category of obstructive sleep apnoea severity, multi-level obstruction was more prevalent. Multi-level obstruction was associated with severe obstructive sleep apnoea (more than 30 events per hour) (p = 0.001). Obstructive sleep apnoea severity increased with the number of obstruction sites (correlation coefficient = 0.303, p < 0.001). Multi-level obstruction was more likely in younger (p = 0.042), male (p = 0.045) patients, with high body mass index (more than 30 kg/m2) (p < 0.001). Palatal (p = 0.004), tongue (p = 0.026) and lateral pharyngeal wall obstructions (p = 0.006) were associated with severe obstructive sleep apnoea. Multi-level obstruction is more prevalent in obstructive sleep apnoea and is associated with increased severity. Obstruction at certain anatomical levels contributes more towards obstructive sleep apnoea severity.

  7. Hair sensor using a photoelectronic principle for sensing airflow and its direction

    NASA Astrophysics Data System (ADS)

    Huang, Kuang-Yuh; Huang, Chien-Tai

    2011-01-01

    Many organisms have diverse hair cells to instantaneously perceive the change of surroundings so that they can keep away from threats. These organs can precisely detect the tiny variations of airflow, water flow, sound, or pressure, and also resolve their affecting directions. Through this brilliant inspiration by the insects' cilia, we decided to design and develop a hair sensor for detecting two-dimensional airflow and pressure waves by using photoelectronic principles. The hair sensor inherently consists of an artificial cilium supported by an elastic membrane. A light-emitting diode and a quadrant photodiode are used as the photoelectronic sensor. The airflow or pressure wave directly stimulates the cilium to sway, and this motion contributes to let the projected light beam shift over the quadrant photodiode, whose four photodiodes produce then corresponding output signals. Because of dynamic and high-sensitive properties of the photoelectronic sensor, the hair sensor we developed possesses a high measurement resolution to be able to detect very tiny stimulation and its affecting direction. According to its multifaceted characteristics and simple structure, the hair sensor can be applied in numerous potential application fields, such as intrusion alarm system, noise detection system, as well as a tactile sensor.

  8. Use of electronic data and existing screening tools to identify clinically significant obstructive sleep apnea.

    PubMed

    Severson, Carl A; Pendharkar, Sachin R; Ronksley, Paul E; Tsai, Willis H

    2015-01-01

    To assess the ability of electronic health data and existing screening tools to identify clinically significant obstructive sleep apnea (OSA), as defined by symptomatic or severe OSA. The present retrospective cohort study of 1041 patients referred for sleep diagnostic testing was undertaken at a tertiary sleep centre in Calgary, Alberta. A diagnosis of clinically significant OSA or an alternative sleep diagnosis was assigned to each patient through blinded independent chart review by two sleep physicians. Predictive variables were identified from online questionnaire data, and diagnostic algorithms were developed. The performance of electronically derived algorithms for identifying patients with clinically significant OSA was determined. Diagnostic performance of these algorithms was compared with versions of the STOP-Bang questionnaire and adjusted neck circumference score (ANC) derived from electronic data. Electronic questionnaire data were highly sensitive (>95%) at identifying clinically significant OSA, but not specific. Sleep diagnostic testing-determined respiratory disturbance index was very specific (specificity ≥95%) for clinically relevant disease, but not sensitive (<35%). Derived algorithms had similar accuracy to the STOP-Bang or ANC, but required fewer questions and calculations. These data suggest that a two-step process using a small number of clinical variables (maximizing sensitivity) and objective diagnostic testing (maximizing specificity) is required to identify clinically significant OSA. When used in an online setting, simple algorithms can identify clinically relevant OSA with similar performance to existing decision rules such as the STOP-Bang or ANC.

  9. Airway epithelial stem cells and the pathophysiology of chronic obstructive pulmonary disease.

    PubMed

    Randell, Scott H

    2006-11-01

    Characteristic pathologic changes in chronic obstructive pulmonary disease (COPD) include an increased fractional volume of bronchiolar epithelial cells, fibrous thickening of the airway wall, and luminal inflammatory mucus exudates, which are positively correlated with airflow limitation and disease severity. The mechanisms driving general epithelial expansion, mucous secretory cell hyperplasia, and mucus accumulation must relate to the effects of initial toxic exposures on patterns of epithelial stem and progenitor cell proliferation and differentiation, eventually resulting in a self-perpetuating, and difficult to reverse, cycle of injury and repair. In this review, current concepts in stem cell biology and progenitor-progeny relationships related to COPD are discussed, focusing on the factors, pathways, and mechanisms leading to mucous secretory cell hyperplasia and mucus accumulation in the airways. A better understanding of alterations in airway epithelial phenotype in COPD will provide a logical basis for novel therapeutic approaches.

  10. Prevalence of chronic obstructive pulmonary disease in independent community-dwelling older adults: The Fujiwara-kyo study.

    PubMed

    Yoshikawa, Masanori; Yamamoto, Yoshifumi; Tomoda, Koichi; Fujita, Yukio; Yamauchi, Motoo; Osa, Takao; Uyama, Hiroki; Okamoto, Nozomi; Kurumatani, Norio; Kimura, Hiroshi

    2017-12-01

    As the Japanese population ages, the number of older patients with chronic obstructive pulmonary disease (COPD) is expected to increase, but the prevalence of COPD in patients aged ≥80 years remains unclear. The purpose of the present study was to determine the prevalence of COPD in independent community-dwelling older adults aged ≥80 years. We investigated the prevalence of COPD in 2862 independent community-dwelling older adults (1504 men, 1358 women, mean age 77.7 ± 7.0 years) who underwent spirometry in the Fujiwara-kyo study, a study of successful aging in older adults. Those participants with airflow limitation (forced expiratory volume in 1 s/forced vital capacity <0.7) who indicated on a self-administered questionnaire that they had a history of smoking and did not have bronchial asthma were considered to have COPD. The prevalence of COPD was 16.9% among all participants and 37.4% among smokers. The prevalence among individuals aged ≥80 years (19.7%) was significantly higher than that among those aged <80 years (16.0%; P < 0.05). When forced expiratory volume in 1 s/forced vital capacity lower limit of normal was used as the criterion for airflow limitation, the prevalence fell to 11.0%. Patients with mild-to-moderate airflow limitation (stage I/stage II) accounted for the great majority (91.2%) of COPD patients aged ≥80 years. A high prevalence of mild-to-moderate COPD was observed even in the independent community-dwelling older adults aged ≥80 years. However, the benefits of the spirometric screening and treatment for these patients needs to be determined. Geriatr Gerontol Int 2017; 17: 2421-2426. © 2017 Japan Geriatrics Society.

  11. Characterization of Asthma-Chronic Obstructive Pulmonary Disease Overlap Syndrome: A Qualitative Analysis.

    PubMed

    Rodrigue, Claudie; Beauchesne, Marie-France; Mallette, Valérie; Lemière, Catherine; Larivée, Pierre; Blais, Lucie

    2017-06-01

    Approximately 15-20% of patients with chronic obstructive pulmonary disease (COPD) also display characteristics of asthma. In May 2014, the asthma-COPD overlap syndrome (ACOS) was briefly addressed in the Global Initiative for Asthma (GINA) and Global Initiative for Chronic Obstructive Lung Disease (GOLD) strategy documents. We evaluated how pulmonologists diagnose and treat ACOS and how they assess its control. Pulmonologists from two university healthcare centers, having ≥ 1 year experience, treating patients with asthma, COPD, or ACOS, were invited to participate in focus groups. Two focus groups (1 hour duration) were convened with seven and five participants, respectively. According to pulmonologists from both institutions, ACOS is a new name for an existing syndrome rather than a new disease. It is characterized by incomplete reversible airflow limitations and changes in forced expiratory volume in one second over time. The pulmonologists noted that its diagnosis must be based on clinical characteristics, pulmonary function test results, and clinical intuition. To diagnose ACOS, pulmonologists must rely on their clinical judgment. They also agreed that the treatment of patients with ACOS should target the features of both asthma and COPD. Pulmonologists from both institutions used asthma control criteria to assess ACOS control. A deeper understanding would enable clinicians to establish specific criteria for the diagnosis, treatment, and follow-up of subjects with ACOS.

  12. The Relationship of Bone Mineral Density in Men with Chronic Obstructive Pulmonary Disease Classified According to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) Combined Chronic Obstructive Pulmonary Disease (COPD) Assessment System.

    PubMed

    Sakurai-Iesato, Yoriko; Kawata, Naoko; Tada, Yuji; Iesato, Ken; Matsuura, Yukiko; Yahaba, Misuzu; Suzuki, Toshio; Ikari, Jun; Yanagawa, Noriyuki; Kasahara, Yasunori; West, James; Tatsumi, Koichiro

    2017-01-01

    Objective Osteoporosis, which is now recognized as a major comorbidity of chronic obstructive pulmonary disease (COPD), must be diagnosed by appropriate methods. The aims of this study were to clarify the relationships between bone mineral density (BMD) and COPD-related clinical variables and to explore the association of BMD with the updated Global Initiative for Chronic Obstructive Lung Disease (GOLD) classification in men. Methods We enrolled 50 Japanese men with clinically stable COPD who underwent dual-energy X-ray absorptiometry (DEXA), pulmonary function testing, and computerized tomography (CT) and who had completed a questionnaire (COPD assessment test [CAT]). We determined the association between the T-score and other tested parameters and compared the BMD of patients in each GOLD category. Results Twenty-three of the 50 patients (46.0%) were diagnosed with osteopenia, and 7 (14.0%) were diagnosed with osteoporosis. The BMD findings were significantly correlated with the CAT score, forced expiratory volume in 1 second percentage predicted (FEV 1 % predicted), low attenuation volume percentage (LAV%), and percentage of cross-sectional area of small pulmonary vessels (%CSA) on CT images. Notably, the median T-score of the GOLD category D participants was significantly lower than that of the participants in each of the other categories (A [-0.98], B [-1.06], C [-1.05], and D [-2.19], p<0.05). Conclusion Reduced BMD was associated with airflow limitation, extent of radiographic findings, and a poor quality of life (QOL) in patients with COPD. The BMD of GOLD category D patients was the lowest of all of the patients evaluated, and category D patients may benefit from active intervention for osteoporosis.

  13. The Relationship of Bone Mineral Density in Men with Chronic Obstructive Pulmonary Disease Classified According to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) Combined Chronic Obstructive Pulmonary Disease (COPD) Assessment System

    PubMed Central

    Sakurai-Iesato, Yoriko; Kawata, Naoko; Tada, Yuji; Iesato, Ken; Matsuura, Yukiko; Yahaba, Misuzu; Suzuki, Toshio; Ikari, Jun; Yanagawa, Noriyuki; Kasahara, Yasunori; West, James; Tatsumi, Koichiro

    2017-01-01

    Objective Osteoporosis, which is now recognized as a major comorbidity of chronic obstructive pulmonary disease (COPD), must be diagnosed by appropriate methods. The aims of this study were to clarify the relationships between bone mineral density (BMD) and COPD-related clinical variables and to explore the association of BMD with the updated Global Initiative for Chronic Obstructive Lung Disease (GOLD) classification in men. Methods We enrolled 50 Japanese men with clinically stable COPD who underwent dual-energy X-ray absorptiometry (DEXA), pulmonary function testing, and computerized tomography (CT) and who had completed a questionnaire (COPD assessment test [CAT]). We determined the association between the T-score and other tested parameters and compared the BMD of patients in each GOLD category. Results Twenty-three of the 50 patients (46.0%) were diagnosed with osteopenia, and 7 (14.0%) were diagnosed with osteoporosis. The BMD findings were significantly correlated with the CAT score, forced expiratory volume in 1 second percentage predicted (FEV1% predicted), low attenuation volume percentage (LAV%), and percentage of cross-sectional area of small pulmonary vessels (%CSA) on CT images. Notably, the median T-score of the GOLD category D participants was significantly lower than that of the participants in each of the other categories (A [-0.98], B [-1.06], C [-1.05], and D [-2.19], p<0.05). Conclusion Reduced BMD was associated with airflow limitation, extent of radiographic findings, and a poor quality of life (QOL) in patients with COPD. The BMD of GOLD category D patients was the lowest of all of the patients evaluated, and category D patients may benefit from active intervention for osteoporosis. PMID:28717072

  14. The effects of acupoint-catgut embedment combined with medical treatment on the BODE index scores of chronic obstructive pulmonary disease (COPD) patients

    NASA Astrophysics Data System (ADS)

    Giri, P. B. S. W.; Srilestari, A.; Abdurrohim, K.; Yunus, F.

    2017-08-01

    Chronic Obstructive Pulmonary Disease (COPD) is now the fourth leading cause of death in the world. As COPD medications are associated with high mortality levels, continuous research into the improvement of treatment modalities is being conducted. This study aimed to identify the effects of acupoint-catgut embedment combined with medical treatment on the Body mass index, airflow Obstruction, Dyspnea and Exercise capacity (BODE) index scores of COPD patients. A single-blind randomized controlled trial was conducted on 48 patients; participants were allocated into either the acupoint-catgut embedment with medication group (case group) or the sham acupuncture with medication group (control group). Acupoint-catgut embedment was conducted at the BL13 Feishu, BL43 Gaohuangshu, BL20 Pishu, BL23 Shenshu, and ST40 Fenglong points two times at an interval of 15 days. The BODE index, a primary outcome indicator, was assessed on Day 1 and Day 30. The results showed statistically and clinically significant differences between the two groups—in fact, BODE index scores were reduced by 1.83 points in the case group (p = 0.000). Ultimately, BODE index scores were lower in the intervention group than in the control group, thus indicating a statistically significant and clinically important improvement of COPD-related symptoms. According to these results, acupoint-catgut embedment combined with medical treatment is concluded to be more effective than medical treatment alone in reducing BODE index scores.

  15. Determinants of spirometric abnormalities among silicotic patients in Hong Kong.

    PubMed

    Leung, Chi C; Chang, Kwok C; Law, Wing S; Yew, Wing W; Tam, Cheuk M; Chan, Chi K; Wong, Man Y

    2005-09-01

    Silicosis is the second commonest notified occupational disease in Hong Kong. To characterize the determinants of spirometric abnormalities in silicosis. The spirometric patterns of consecutive silicotic patients on confirmation by the Pneumoconiosis Medical Board from 1991 to 2002 were correlated with demographic characteristics, occupational history, smoking history, tuberculosis (TB) history and radiographic features by univariate and multiple regression analyses. Of 1576 silicotic patients included, 55.6% showed normal spirometry, 28.5% normal forced vital capacity (FVC>or=80% predicted) but reduced forced expiratory ratio (FER<70%), 7.6% reduced FVC but normal FER, and 8.4% reduced both FVC and FER. Age, ever-smoking, cigarette pack-years, industry, job type, history of TB, size of lung nodules and progressive massive fibrosis (PMF) were all significantly associated with airflow limitation on univariate analysis (all P<0.05), while sex and profusion of nodules were not. Only age, cigarette pack-years, history of TB, size of lung nodules and PMF remained as significant independent predictors of airflow obstruction in multiple logistic regression analysis. After controlling for airflow obstruction, only shorter exposure duration, history of TB and profusion of nodules were significant independent predictors of reduced FVC. As well as age, history of TB, cigarette pack-years, PMF and nodule size contributed comparable effects to airflow obstruction in multiple linear regression analyses, while profusion of nodules was the strongest factor for reduced vital capacity. In an occupational compensation setting, disease indices and history of tuberculosis are independent predictors of both airflow obstruction and reduced vital capacity for silicotic patients.

  16. A Cross-sectional Assessment of Health-related Quality of Life among Patients with Chronic Obstructive Pulmonary Disease.

    PubMed

    Garcia-Gordillo, Miguel Ángel; Collado-Mateo, Daniel; Olivares, Pedro Rufino; Adsuar, José Carmelo; Merellano-Navarro, Eugenio

    2017-08-01

    Chronic obstructive pulmonary disease (COPD) is a major cause of mortality characterized by progressive airflow obstruction and inflammation in the airways, which has an impact on health-related quality of life. The EQ-5D-5L is one of the most used preference-based, health-related quality of life questionnaire. The objective of this study was to provide normative values of EQ-5D-5L for Spanish people suffering from COPD. Data were extracted from the Spanish National Health Survey (2011/2012). Overall, 1130 people with COPD participated in this survey. The utility index of EQ-5D-5L and the Visual Analog Scale (VAS) score were defined by gender, region, and age. Mean (SD) EQ-5D-5L utility index and VAS score for Spanish people with COPD were 0.742 (0.309) and 60.466 (21.934) respectively. In general, men reported better health status than women. Ceiling effect of the whole sample was 30.35%. The current study provides normative values of EQ-5D-5L for Spanish people affected by COPD. Ceiling effect was high and better results were observed in men compared with women.

  17. Human-Mediated Dispersal of Seeds by the Airflow of Vehicles

    PubMed Central

    von der Lippe, Moritz; Bullock, James M.; Kowarik, Ingo; Knopp, Tatjana; Wichmann, Matthias

    2013-01-01

    Human-mediated dispersal is known as an important driver of long-distance dispersal for plants but underlying mechanisms have rarely been assessed. Road corridors function as routes of secondary dispersal for many plant species but the extent to which vehicles support this process remains unclear. In this paper we quantify dispersal distances and seed deposition of plant species moved over the ground by the slipstream of passing cars. We exposed marked seeds of four species on a section of road and drove a car along the road at a speed of 48 km/h. By tracking seeds we quantified movement parallel as well as lateral to the road, resulting dispersal kernels, and the effect of repeated vehicle passes. Median distances travelled by seeds along the road were about eight meters for species with wind dispersal morphologies and one meter for species without such adaptations. Airflow created by the car lifted seeds and resulted in longitudinal dispersal. Single seeds reached our maximum measuring distance of 45 m and for some species exceeded distances under primary dispersal. Mathematical models were fit to dispersal kernels. The incremental effect of passing vehicles on longitudinal dispersal decreased with increasing number of passes as seeds accumulated at road verges. We conclude that dispersal by vehicle airflow facilitates seed movement along roads and accumulation of seeds in roadside habitats. Dispersal by vehicle airflow can aid the spread of plant species and thus has wide implications for roadside ecology, invasion biology and nature conservation. PMID:23320077

  18. Control of nasal vasculature and airflow resistance in the dog.

    PubMed Central

    Lung, M A; Phipps, R J; Wang, J C; Widdicombe, J G

    1984-01-01

    Nasal vascular and airflow resistances have been measured in dogs, simultaneously on both sides separately. Vascular resistance was measured either by constant flow perfusion of the terminal branch of the maxillary artery (which supplies, via the sphenopalatine artery, the nasal septum, most of the turbinates and the nasal sinuses) or by measuring blood flow through this artery, maintained by the dog's own blood pressure. Airflow resistance was assessed by inserting balloon-tipped endotracheal catheters into the back of each nasal cavity via the nasopharynx, and measuring transnasal pressure at constant airflow through each side of the nose simultaneously. Preliminary experiments indicated that there was 5-10% collateral anastomosis between the two sides. Close-arterial injection of drugs showed different patterns of response. Adrenaline, phenylephrine, chlorpheniramine and low doses of prostaglandin F2 alpha increased vascular resistance and lowered airway resistance. Salbutamol, methacholine and histamine lowered vascular resistance and increased airway resistance. Dobutamine decreased airway resistance with a small increase in vascular resistance. Prostaglandins E1, E2 and F2 alpha (high dose) decreased both vascular and airway resistances. Substance P, eledoisin-related peptide and vasoactive intestinal polypeptide lowered vascular resistance with little change in airway resistance. The results are interpreted in terms of possible drug actions on precapillary resistance vessels, sinusoids and venules, and arteriovenous anastomoses. It is concluded that nasal airway resistance cannot be correlated with vascular resistance or blood flow, since the latter has a complex and ill-defined relationship with nasal vascular blood volume. PMID:6204040

  19. Control of nasal vasculature and airflow resistance in the dog.

    PubMed

    Lung, M A; Phipps, R J; Wang, J C; Widdicombe, J G

    1984-04-01

    Nasal vascular and airflow resistances have been measured in dogs, simultaneously on both sides separately. Vascular resistance was measured either by constant flow perfusion of the terminal branch of the maxillary artery (which supplies, via the sphenopalatine artery, the nasal septum, most of the turbinates and the nasal sinuses) or by measuring blood flow through this artery, maintained by the dog's own blood pressure. Airflow resistance was assessed by inserting balloon-tipped endotracheal catheters into the back of each nasal cavity via the nasopharynx, and measuring transnasal pressure at constant airflow through each side of the nose simultaneously. Preliminary experiments indicated that there was 5-10% collateral anastomosis between the two sides. Close-arterial injection of drugs showed different patterns of response. Adrenaline, phenylephrine, chlorpheniramine and low doses of prostaglandin F2 alpha increased vascular resistance and lowered airway resistance. Salbutamol, methacholine and histamine lowered vascular resistance and increased airway resistance. Dobutamine decreased airway resistance with a small increase in vascular resistance. Prostaglandins E1, E2 and F2 alpha (high dose) decreased both vascular and airway resistances. Substance P, eledoisin-related peptide and vasoactive intestinal polypeptide lowered vascular resistance with little change in airway resistance. The results are interpreted in terms of possible drug actions on precapillary resistance vessels, sinusoids and venules, and arteriovenous anastomoses. It is concluded that nasal airway resistance cannot be correlated with vascular resistance or blood flow, since the latter has a complex and ill-defined relationship with nasal vascular blood volume.

  20. Signs of Gas Trapping in Normal Lung Density Regions in Smokers.

    PubMed

    Bodduluri, Sandeep; Reinhardt, Joseph M; Hoffman, Eric A; Newell, John D; Nath, Hrudaya; Dransfield, Mark T; Bhatt, Surya P

    2017-12-01

    A substantial proportion of subjects without overt airflow obstruction have significant respiratory morbidity and structural abnormalities as visualized by computed tomography. Whether regions of the lung that appear normal using traditional computed tomography criteria have mild disease is not known. To identify subthreshold structural disease in normal-appearing lung regions in smokers. We analyzed 8,034 subjects with complete inspiratory and expiratory computed tomographic data participating in the COPDGene Study, including 103 lifetime nonsmokers. The ratio of the mean lung density at end expiration (E) to end inspiration (I) was calculated in lung regions with normal density (ND) by traditional thresholds for mild emphysema (-910 Hounsfield units) and gas trapping (-856 Hounsfield units) to derive the ND-E/I ratio. Multivariable regression analysis was used to measure the associations between ND-E/I, lung function, and respiratory morbidity. The ND-E/I ratio was greater in smokers than in nonsmokers, and it progressively increased from mild to severe chronic obstructive pulmonary disease severity. A proportion of 26.3% of smokers without airflow obstruction had ND-E/I greater than the 90th percentile of normal. ND-E/I was independently associated with FEV 1 (adjusted β = -0.020; 95% confidence interval [CI], -0.032 to -0.007; P = 0.001), St. George's Respiratory Questionnaire scores (adjusted β = 0.952; 95% CI, 0.529 to 1.374; P < 0.001), 6-minute-walk distance (adjusted β = -10.412; 95% CI, -12.267 to -8.556; P < 0.001), and body mass index, airflow obstruction, dyspnea, and exercise capacity index (adjusted β = 0.169; 95% CI, 0.148 to 0.190; P < 0.001), and also with FEV 1 change at follow-up (adjusted β = -3.013; 95% CI, -4.478 to -1.548; P = 0.001). Subthreshold gas trapping representing mild small airway disease is prevalent in normal-appearing lung regions in smokers without airflow obstruction, and it is

  1. Airflow and thrust calibration of an F100 engine, S/N P680059, at selected flight conditions

    NASA Technical Reports Server (NTRS)

    Biesiadny, T. J.; Lee, D.; Rodriguez, J. R.

    1978-01-01

    An airflow and thrust calibration of an F100 engine, S/N P680059, was conducted to study airframe propulsion system integration losses in turbofan-powered high-performance aircraft. The tests were conducted with and without thrust augmentation for a variety of simulated flight conditions with emphasis on the transonic regime. The resulting corrected airflow data generalized into one curve with corrected fan speed while corrected gross thrust increased as simulated flight conditions increased. Overall agreement between measured data and computed results was 1 percent for corrected airflow and -1 1/2 percent for gross thrust. The results of an uncertainty analysis are presented for both parameters at each simulated flight condition.

  2. The Role of Innate and Adaptive Immune Cells in the Immunopathogenesis of Chronic Obstructive Pulmonary Disease.

    PubMed

    Nurwidya, Fariz; Damayanti, Triya; Yunus, Faisal

    2016-01-01

    Chronic obstructive pulmonary disease (COPD) is a chronic and progressive inflammatory disease of the airways and lungs that results in limitations of continuous airflow and is caused by exposure to noxious gasses and particles. A major cause of morbidity and mortality in adults, COPD is a complex disease pathologically mediated by many inflammatory pathways. Macrophages, neutrophils, dendritic cells, and CD8+ T-lymphocytes are the key inflammatory cells involved in COPD. Recently, the non-coding small RNA, micro-RNA, have also been intensively investigated and evidence suggest that it plays a role in the pathogenesis of COPD. Here, we discuss the accumulated evidence that has since revealed the role of each inflammatory cell and their involvement in the immunopathogenesis of COPD. Mechanisms of steroid resistance in COPD will also be briefly discussed.

  3. Study of Airflow Out of the Mouth During Speech.

    ERIC Educational Resources Information Center

    Catford, J.C.; And Others

    Airflow outside the mouth is diagnostic of articulatory activities in the vocal tract, both total volume-velocity and the distribution of particle velocities over the flow-front being useful for this purpose. A system for recording and displaying both these types of information is described. This consists of a matrix of l6 hot-wire anemometer flow…

  4. Congenital Urinary Tract Obstruction: The Long View

    PubMed Central

    Chevalier, Robert L.

    2015-01-01

    Maldevelopment of the collecting system resulting in urinary tract obstruction (UTO) is the leading identifiable cause of CKD in children. Specific etiologies are unknown; most cases are suspected by discovering hydronephrosis on prenatal ultrasonography. Congenital UTO can reduce nephron number and cause bladder dysfunction, which contribute to ongoing injury. Severe UTO can impair kidney growth in utero, and animal models of unilateral ureteral obstruction show that ischemia and oxidative stress cause proximal tubular cell death, with later development of interstitial fibrosis. Congenital obstructive nephropathy therefore results from combined developmental and obstructive renal injury. Due to inadequacy of available biomarkers, criteria for surgical correction of upper tract obstruction are poorly established. Lower tract obstruction requires fetal or immediate postnatal intervention, and the rate of progression of CKD is highly variable. New biomarkers based on proteomics and determination of glomerular number by MRI should improve future care. Angiotensin inhibitors have not been effective in slowing progression, although avoidance of nephrotoxins and timely treatment of hypertension are important. Because congenital UTO begins in fetal life, smooth transfer of care from perinatologist to pediatric and adult urology and nephrology teams should optimize quality of life and ultimate outcomes for these patients. PMID:26088076

  5. Falls in patients with chronic obstructive pulmonary disease: a call for further research

    PubMed Central

    Roig, M; Eng, JJ; MacIntyre, DL; Road, JD; Reid, WD.

    2012-01-01

    Summary Chronic obstructive pulmonary disease (COPD) is a respiratory disease that results in airflow limitation and respiratory distress. The effects of COPD, however, are not exclusively limited to respiratory function and people with COPD face many non-respiratory manifestations that affect both function and mobility. Deficits in function and mobility have been associated with an increased risk for falling in older adults. The purpose of this study was to provide a theoretical framework to identify risks factors for falls in people with COPD. We have analyzed the literature to identify possible relationships between pathophysiological changes observed in COPD and common risk factors for falls. Well-established fall risk factors in people with COPD include lower limb muscle weakness and impaired activities of daily living. Other intrinsic risk factors such as gait and balance deficits, nutritional depletion, malnutrition, depression, cognitive impairments and medications are possible risk factors that need to be confirmed with more studies. There is no evidence that visual deficits are common in COPD. The role that precipitating factors such as syncope and postural hypotension may have on fall risk is unclear. Exacerbations and dyspnea do not have a precipitating effect on fall risk but they contribute to the progressive physical deterioration that may theoretically increase the risk for falls. While these results suggest that people with COPD might have an increased susceptibility to fall compared to their healthy peers, further research is needed to determine the prevalence of falls and specific risk factors for falls in people living with COPD. PMID:19419852

  6. Estimation of the site of wheezes in pulmonary emphysema: airflow simulation study by the use of A 4D lung model.

    PubMed

    Kitaoka, Hiroko; Cok, Salim

    2013-01-01

    Adventitious lung sounds in pulmonary emphysema, wheezes, are continuous musical sounds during expiration with 400 Hz or more. The textbook tells that expiratory airflow limitation in emphysema occurs at the peripheral airways and that wheezes are generated there. We have recently proposed a novel hypothesis based on image analysis and theoretical consideration that expiratory airflow limitation in emphysema occurs at the intra-mediastinal airway (trachea, main bronchi, and right lobar bronchi) due to compression by overinflated lungs. We performed expiratory airflow simulation by the use of a 4D finite element lung model, and found periodical vortex release with 300-900 Hz at the end of protrusion of the the tracheal posterior wall. Relationship between the peak frequency of pressure fluctuation and airflow velocity was in agreement with Strahal's law either in normal or emphysematous condition. Contrarily, airflow simulation in a small bronchus (1.5 mm in diameter) indicated no apparent periodic vortex release.

  7. Relationship between Pulmonary Airflow and Resistance in Patients with Airway Narrowing Using An 1-D Network Resistance and Compliance Model

    NASA Astrophysics Data System (ADS)

    Choi, Sanghun; Choi, Jiwoong; Hoffman, Eric; Lin, Ching-Long

    2016-11-01

    To predict the proper relationship between airway resistance and regional airflow, we proposed a novel 1-D network model for airway resistance and acinar compliance. First, we extracted 1-D skeletons at inspiration images, and generated 1-D trees of CT unresolved airways with a volume filling method. We used Horsfield order with random heterogeneity to create diameters of the generated 1-D trees. We employed a resistance model that accounts for kinetic energy and viscous dissipation (Model A). The resistance model is further coupled with a regional compliance model estimated from two static images (Model B). For validation, we applied both models to a healthy subject. The results showed that Model A failed to provide airflows consistent with air volume change, whereas Model B provided airflows consistent with air volume change. Since airflows shall be regionally consistent with air volume change in patients with normal airways, Model B was validated. Then, we applied Model B to severe asthmatic subjects. The results showed that regional airflows were significantly deviated from air volume change due to airway narrowing. This implies that airway resistance plays a major role in determining regional airflows of patients with airway narrowing. Support for this study was provided, in part, by NIH Grants U01 HL114494, R01 HL094315, R01 HL112986, and S10 RR022421.

  8. Velopharyngeal mucosal surface topography in healthy subjects and subjects with obstructive sleep apnea.

    PubMed

    Lambeth, Christopher; Amatoury, Jason; Wang, Ziyu; Foster, Sheryl; Amis, Terence; Kairaitis, Kristina

    2017-03-01

    describe the mucosal surface roughness. Increased roughness was found in the obstructive sleep apnea vs. healthy group, but further research is required to determine the functional effects of the measured difference on upper airway airflow mechanics. Copyright © 2017 the American Physiological Society.

  9. Toward smart Nebulization: Engineering acoustic airflow to penetrate maxillary sinuses in chronic rhinosinusitis.

    PubMed

    Moghadam, Shima Jowhari; Navarro, Laurent; Leclerc, Lara; Hodin, Sophie; Pourchez, Jérémie

    2018-07-30

    Treating chronic rhinosinusitis (CRS) by nebulization requires an airflow capable to deliver medication to deep target sites beyond the nasal valve. Fixed frequency acoustic airflow technology is currently available, mainly as post-surgical therapy, but still have not been able to realize the full potential of direct nose to paranasal sinuses delivery. Reported herein are the application of frequency sweep acoustic airflow and the optimization of its frequency range, sweep cycle duration and intensity. The resonant frequencies of the model's maxillary sinuses can be estimated using the Helmholtz resonator theory. Results indicated a resonant frequency of 479 Hz for the right maxillary sinus and one of 849 Hz for the left maxillary sinus. The highest intrasinus deposition within the experiments are from sweep cycle duration of 1 s, intensity of 80 dB, and frequency range of 100-850 Hz. The optimal range of frequency determined from experiments is in good agreement with the corresponding frequency range obtained from the Helmholtz resonator theory. Results reveal a significantly enhanced maxillary sinus drug deposition. This technique affords the potential of treating CRS. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Impact of acoustic airflow on intrasinus drug deposition: New insights into the vibrating mode and the optimal acoustic frequency to enhance the delivery of nebulized antibiotic.

    PubMed

    Leclerc, Lara; Merhie, Amira El; Navarro, Laurent; Prévôt, Nathalie; Durand, Marc; Pourchez, Jérémie

    2015-10-15

    We investigated the impact of vibrating acoustic airflow, the high frequency (f≥100 Hz) and the low frequency (f≤45 Hz) sound waves, on the enhancement of intrasinus drug deposition. (81m)Kr-gas ventilation study was performed in a plastinated human cast with and without the addition of vibrating acoustic airflow. Similarly, intrasinus drug deposition in a nasal replica using gentamicin as a marker was studied with and without the superposition of different modes of acoustic airflow. Ventilation experiments demonstrate that no sinus ventilation was observed without acoustic airflow although sinus ventilation occurred whatever the modes of acoustic airflow applied. Intrasinus drug deposition experiments showed that the high frequency acoustic airflow led to 4-fold increase in gentamicin deposition into the left maxillary sinus and to 2-fold deposition increase into the right maxillary sinus. Besides, the low frequency acoustic airflow demonstrated a significant increase of 4-fold and 2-fold in the right and left maxillary sinuses, respectively. We demonstrated the benefit of different modes of vibrating acoustic airflow for maxillary sinus ventilation and intrasinus drug deposition. The degree of gentamicin deposition varies as a function of frequency of the vibrating acoustic airflow and the geometry of the ostia. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. A Comparative Study of Airflow and Odorant Deposition in the Mammalian Nasal Cavity

    NASA Astrophysics Data System (ADS)

    Richter, Joseph; Rumple, Christopher; Ranslow, Allison; Quigley, Andrew; Pang, Benison; Neuberger, Thomas; Krane, Michael; van Valkenburgh, Blaire; Craven, Brent

    2013-11-01

    The complex structure of the mammalian nasal cavity provides a tortuous airflow path and a large surface area for respiratory air conditioning, filtering of inspired contaminants, and olfaction. Due to the small and contorted structure of the nasal turbinals, nasal anatomy and function remains poorly understood in most mammals. Here, we utilize high-resolution MRI scans to reconstruct anatomically-accurate models of the mammalian nasal cavity. These data are used to compare the form and function of the mammalian nose. High-fidelity computational fluid dynamics (CFD) simulations of nasal airflow and odorant deposition are presented and used to compare olfactory function across species (primate, rodent, canine, feline, ungulate).

  12. Thermal performance characterization of residential wall systems using a calibrated hot box with airflow induced by differential pressures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, D.C.; Ober, D.G.; Goodrow, J.T.

    1995-09-01

    ASTM E 283 ad ASTM E 1424 in conjunction with ASTM C 976 were used to study the effect of airflow on thermal performance of the wall. A typical residential 2 {times} 4 stud wall was constructed and placed on top of a subfloor, making a 2.44 {times} 2.74 m (8 by 9 ft) test specimen. This base wall assembly was then covered with two types of XPS sheathing, various housewraps, a 15{number_sign} felt, and a polyethylene vapor retarder film in 40 different configurations and tested individually per ASTM E 283 and per ASTM C 976. For 24 of themore » 40 C 976 tests, a differential pressure was induced across the test wall as per and ASTM E 1424. Airflows ranged from undetectable airflow at 0 {center_dot} Pa {Delta}P to 1.63 L/s {center_dot} m{sup 2} for the base wall assembly alone. Difference in airflow resistance performance between the ASTM E 283 and ASTM E 1424 test methods were noted. Thermal testing results incorporating both ASTM C 976 and ASTM E 1424 for tests 1--28 produced apparent thermal conductances (C-values) in the range of 0.40 W/m{sup 2} {center_dot} K for a nondetectable airflow level to 1.81 W/m{sup 2} {center_dot} K for an airflow of 1.53 L/s {center_dot} m{sup 2} for the base wall assembly alone with a 20-Pa {Delta}P. The calculated C-value for this base wall assembly was 0.40 W/m{sup 2} {center_dot} K. Test results reveal that airflow rates as low as 0.2 L/s {center_dot} m{sup 2} could produce a 46% increase in apparent C-value. Similar thermal performance differences were revealed when thicker shiplap XPS sheathing was used. Tests were also conducted using an Air-Tight Drywall configuration showing the effect of wind washing on thermal performance. By sealing the gypsum drywall on the base wall assembly tested, the apparent C-value, when exposed to a 12.5 Pa wind pressure, was found to be equivalent to a base wall assembly configuration which allows 0.15 L/s {center_dot} m{sup 2} airflow to penetrate completely through.« less

  13. Airflow and nanoparticle deposition in a 16-generation tracheobronchial airway model

    EPA Science Inventory

    In order to achieve both manageable simulation and local accuracy of airflow and nanoparticle deposition in a representative human tracheobronchial (TB) region, the complex airway network was decomposed into adjustable triple-bifurcation units, spreading axially and laterally. Gi...

  14. Forced-air patient warming blankets disrupt unidirectional airflow.

    PubMed

    Legg, A J; Hamer, A J

    2013-03-01

    We have recently shown that waste heat from forced-air warming blankets can increase the temperature and concentration of airborne particles over the surgical site. The mechanism for the increased concentration of particles and their site of origin remained unclear. We therefore attempted to visualise the airflow in theatre over a simulated total knee replacement using neutral-buoyancy helium bubbles. Particles were created using a Rocket PS23 smoke machine positioned below the operating table, a potential area of contamination. The same theatre set-up, warming devices and controls were used as in our previous study. This demonstrated that waste heat from the poorly insulated forced-air warming blanket increased the air temperature on the surgical side of the drape by > 5°C. This created convection currents that rose against the downward unidirectional airflow, causing turbulence over the patient. The convection currents increased the particle concentration 1000-fold (2 174 000 particles/m(3) for forced-air warming vs 1000 particles/m(3) for radiant warming and 2000 particles/m(3) for the control) by drawing potentially contaminated particles from below the operating table into the surgical site. Cite this article: Bone Joint J 2013;95-B:407-10.

  15. Fatigue and multidimensional disease severity in chronic obstructive pulmonary disease.

    PubMed

    Inal-Ince, Deniz; Savci, Sema; Saglam, Melda; Calik, Ebru; Arikan, Hulya; Bosnak-Guclu, Meral; Vardar-Yagli, Naciye; Coplu, Lutfi

    2010-06-30

    Fatigue is associated with longitudinal ratings of health in patients with chronic obstructive pulmonary disease (COPD). Although the degree of airflow obstruction is often used to grade disease severity in patients with COPD, multidimensional grading systems have recently been developed. The aim of this study was to investigate the relationship between perceived and actual fatigue level and multidimensional disease severity in patients with COPD. Twenty-two patients with COPD (aged 52-74 years) took part in the study. Multidimensional disease severity was measured using the SAFE and BODE indices. Perceived fatigue was assessed using the Fatigue Severity Scale (FSS) and the Fatigue Impact Scale (FIS). Peripheral muscle endurance was evaluated using the number of sit-ups, squats, and modified push-ups that each patient could do. Thirteen patients (59%) had severe fatigue, and their St George's Respiratory Questionnaire scores were significantly higher (p < 0.05). The SAFE index score was significantly correlated with the number of sit-ups, number of squats, FSS score and FIS score (p < 0.05). The BODE index was significantly associated with the numbers of sit-ups, squats and modified push-ups, and with the FSS and FIS scores (p < 0.05). Peripheral muscle endurance and fatigue perception in patients with COPD was related to multidimensional disease severity measured with both the SAFE and BODE indices. Improvements in perceived and actual fatigue levels may positively affect multidimensional disease severity and health status in COPD patients. Further research is needed to investigate the effects of fatigue perception and exercise training on patients with different stages of multidimensional COPD severity.

  16. [Correlation between obstructive apnea syndrome and difficult airway in ENT surgery].

    PubMed

    Pera, Marcia Hiray; Tardelli, Maria Angela; Novo, Neil Ferreira; Juliano, Yara; Silva, Helga Cristina Almeida da

    2017-12-21

    ENT patients with obstructive sleep apnea syndrome have a tendency of collapsing the upper airways in addition to anatomical obstacles. Obstructive sleep apnea syndrome is related to the increased risk of difficult airway and also increased perioperative complications. In order to identify these patients in the preoperative period, the STOP Bang questionnaire has been highlighted because it is summarized and easy to apply. Evaluate through the STOP Bang questionnaire whether patients undergoing ENT surgery with a diagnosis of obstructive sleep apnea syndrome have a higher risk of complications, particularly the occurrence of difficult airway. Measurements of anatomical parameters for difficult airway and questionnaire application for clinical prediction of obstructive sleep apnea syndrome were performed in 48 patients with a previous polysomnographic study. The sample detected difficult airway in about 18.7% of patients, all of them with obstructive sleep apnea syndrome. This group had older age, cervical circumference > 40cm, ASA II and Cormack III/IV. Patients with obstructive sleep apnea syndrome had higher body mass index, cervical circumference, and frequent apnea. In subgroup analysis, the group with severe obstructive sleep apnea syndrome showed a significantly higher SB score compared to patients without this syndrome or with a mild/moderate obstructive sleep apnea syndrome. The STOP Bang questionnaire was not able to predict difficult airway and mild obstructive sleep apnea syndrome, but it identified marked obstructive sleep apnea syndrome. All patients with difficult airway had moderate and marked obstructive sleep apnea syndrome, although this syndrome did not involve difficult airway. The variables Cormack III/IV and BMI greater than 35 Kg.m -2 were able to predict difficult airway and obstructive sleep apnea syndrome, respectively. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  17. Sensing fluctuating airflow with spider silk

    PubMed Central

    2017-01-01

    The ultimate aim of flow sensing is to represent the perturbations of the medium perfectly. Hundreds of millions of years of evolution resulted in hair-based flow sensors in terrestrial arthropods that stand out among the most sensitive biological sensors known, even better than photoreceptors which can detect a single photon (10−18–10−19 J) of visible light. These tiny sensory hairs can move with a velocity close to that of the surrounding air at frequencies near their mechanical resonance, despite the low viscosity and low density of air. No man-made technology to date demonstrates comparable efficiency. Here we show that nanodimensional spider silk captures fluctuating airflow with maximum physical efficiency (Vsilk/Vair ∼ 1) from 1 Hz to 50 kHz, providing an effective means for miniaturized flow sensing. Our mathematical model shows excellent agreement with experimental results for silk with various diameters: 500 nm, 1.6 µm, and 3 µm. When a fiber is sufficiently thin, it can move with the medium flow perfectly due to the domination of forces applied to it by the medium over those associated with its mechanical properties. These results suggest that the aerodynamic property of silk can provide an airborne acoustic signal to a spider directly, in addition to the well-known substrate-borne information. By modifying a spider silk to be conductive and transducing its motion using electromagnetic induction, we demonstrate a miniature, directional, broadband, passive, low-cost approach to detect airflow with full fidelity over a frequency bandwidth that easily spans the full range of human hearing, as well as that of many other mammals. PMID:29087323

  18. Detection of changes in respiratory mechanics due to increasing degrees of airway obstruction in asthma by the forced oscillation technique.

    PubMed

    Cavalcanti, Juliana V; Lopes, Agnaldo J; Jansen, José M; Melo, Pedro L

    2006-12-01

    Forced expiratory airflows and volumes are often used to assess the airway obstruction in asthmatics. However, forced maneuvers may change bronchial tone and modify airway patency. The aim of this study was to determine whether the Forced Oscillation Technique (FOT), which does not require forced manoeuvres, may be useful to describe the changes in respiratory mechanics in progressive asthma. This study involved 25 healthy and 84 asthmatics, including patients with normal spirometric exam (NE), mild moderate and severe obstruction. Resistive data were interpreted using the respiratory system resistance extrapolated at 0 Hz (R0), the mean respiratory resistance (Rm), and the resistance/frequency slope (S). Reactance data were interpreted by its mean values (Xm), the dynamic compliance (Crs,dyn), and resonant frequency (fr). Receiver operating characteristics curves were used to determine the sensitivity (Se) and specificity (Sp) of FOT parameters in identifying asthma. There were not statistically significant differences between the control and NE groups. Comparing the control and mild groups, significant increases of R0 (P<0.0007), Rm (P<0.003), and S (P<0.003) were observed. In reactive parameters, a significant reduction in Crs,dyn (P<0.04) was observed, while Xm and fr presented significant increases (P<0.0007 and P<0.006, respectively). Comparison between mild and moderate groups showed non-significant modifications in all of the parameters, except for Xm (P<0.02). In the late stages (moderate to severe obstruction), all of the resistive parameters, as well as the reactive ones Xm (P<0.007) and Crs,dyn (P<0.03), presented statistically significant modifications. Among the studied parameters, the effects of airway obstruction in asthma seem to be well described by R0, Rm, S and Xm, which were in close agreement with physiological fundamentals. The best parameters for detecting asthma were R0 (Se=81%, Sp=76%), S (Se=78%, Sp=72%) and Xm (Se=81%, Sp=80%). In

  19. Influence of liquid-volume and airflow rates on spray application quality and homogeneity in super-intensive olive tree canopies.

    PubMed

    Miranda-Fuentes, Antonio; Rodríguez-Lizana, Antonio; Gil, Emilio; Agüera-Vega, J; Gil-Ribes, Jesús A

    2015-12-15

    Olive is a key crop in Europe, especially in countries around the Mediterranean Basin. Optimising the parameters of a spray is essential for sustainable pesticide use, especially in high-input systems, such as the super-intensive hedgerow system. Parameters may be optimised by adjusting the applied volume and airflow rate of sprays, in addition to the liquid to air proportion and the relationship between air velocity and airflow rate. Two spray experiments using a commercial airblast sprayer were conducted in a super-intensive orchard to study how varying the liquid volume rate (testing volumes of 182, 619, and 1603 l ha(-1)) and volumetric airflow rate (with flow rates of 11.93, 8.90, and 6.15 m(3) s(-1)) influences the coverage parameters and the amount and distribution of deposits in different zones of the canopy.. Our results showed that an increase in the application volume raised the mean deposit and percentage coverage, but decreased the application efficiency, spray penetration, and deposit homogeneity. Furthermore, we found that the volumetric airflow rate had a lower influence on the studied parameters than the liquid volume; however, an increase in the airflow rate improved the application efficiency and homogeneity to a certain threshold, after which the spray quality decreased. This decrease was observed in the high-flow treatment. Our results demonstrate that intermediate liquid volume rates and volumetric airflow rates are required for the optimal spraying of pesticides on super-intensive olive crops, and would reduce current pollution levels. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Nutritional status is related to fat-free mass, exercise capacity and inspiratory strength in severe chronic obstructive pulmonary disease patients.

    PubMed

    Sabino, Pollyane Galinari; Silva, Bruno Moreira; Brunetto, Antonio Fernando

    2010-06-01

    Being overweight or obese is associated with a higher rate of survival in patients with advanced chronic obstructive pulmonary disease (COPD). This paradoxical relationship indicates that the influence of nutritional status on functional parameters should be further investigated. To investigate the impact of nutritional status on body composition, exercise capacity and respiratory muscle strength in severe chronic obstructive pulmonary disease patients. Thirty-two patients (nine women) were divided into three groups according to their body mass indices (BMI): overweight/obese (25 < or = BMI < or = 34.9 kg/m(2), n=8), normal weight (18.5 < or = BMI < or = 24.9 kg/m(2), n=17) and underweight (BMI <18.5 kg/m(2), n=7). Spirometry, bioelectrical impedance, a six-minute walking distance test and maximal inspiratory and expiratory pressures were assessed. Airway obstruction was similar among the groups (p=0.30); however, overweight/obese patients had a higher fat-free mass (FFM) index [FFMI=FFM/body weight(2) (mean+/-SEM: 17+/-0.3 vs. 15+/-0.3 vs. 14+/-0.5 m/kg(2), p<0.01)], exercise capacity (90+/-8 vs. 79+/-6 vs. 57+/-8 m, p=0.02) and maximal inspiratory pressure (63+/-7 vs. 57+/-5 vs. 35+/-8 % predicted, p=0.03) in comparison to normal weight and underweight patients, respectively. In addition, on backward multiple regression analysis, FFMI was the unique independent predictor of exercise capacity (partial r=0.52, p<0.01). Severe chronic obstructive pulmonary disease (COPD) patients who were overweight or obese had a greater FFM, exercise capacity and inspiratory muscle strength than patients with the same degree of airflow obstruction who were of normal weight or underweight, and higher FFM was independently associated with higher exercise capacity. These characteristics of overweight or obese patients might counteract the drawbacks of excess weight and lead to an improved prognosis in COPD.

  1. Hydrocephalus secondary to obstruction of the lateral apertures in two dogs.

    PubMed

    Kent, M; Glass, E N; Haley, A C; Shaikh, L S; Sequel, M; Blas-Machado, U; Bishop, T M; Holmes, S P; Platt, S R

    2016-11-01

    Traditionally, hydrocephalus is divided into communicating or non-communicating (obstructive) based on the identification of a blockage of cerebrospinal fluid (CSF) flow through the ventricular system. Hydrocephalus ex vacuo refers to ventricular enlargement as a consequence of neuroparenchymal loss. Hydrocephalus related to obstruction of the lateral apertures of the fourth ventricles has rarely been described. The clinicopathologic findings in two dogs with hydrocephalus secondary to obstruction of the lateral apertures of the fourth ventricle are reported. Signs were associated with a caudal cervical spinal cord lesion in one dog and a caudal brain stem lesion in the other dog. Magnetic resonance imaging (MRI) disclosed dilation of the ventricular system, including the lateral recesses of the fourth ventricle. In one dog, postmortem ventriculography confirmed obstruction of the lateral apertures. Microscopic changes were identified in the choroid plexus in both dogs, yet a definitive cause of the obstructions was not identified. The MRI findings in both dogs are similar to membranous occlusion of the lateral and median apertures in human patients. MRI detection of dilation of the entire ventricular system in the absence of an identifiable cause should prompt consideration of an obstruction of the lateral apertures. In future cases, therapeutic interventions aimed at re-establishing CSF flow or ventriculoperitoneal catheterisation should be considered. © 2016 Australian Veterinary Association.

  2. Implications of Airflow Dynamics and Soft-Tissue Reconstructions for the Heat Exchange Potential of Dinosaur Nasal Passages

    NASA Astrophysics Data System (ADS)

    Bourke, Jason Michael

    This study seeks to restore the internal anatomy within the nasal passages of dinosaurs via the use of comparative anatomical methods along with computational fluid dynamic simulations. Nasal airway descriptions and airflow simulations are described for extant birds, crocodylians, and lizards. These descriptions served as a baseline for airflow within the nasal passages of diapsids. The presence of shared airflow and soft-tissue properties found in the nasal passages of extant diapsids, were used to restore soft tissues within the airways of dinosaurs under the assumption that biologically unfeasible airflow patterns (e.g., lack of air movement in olfactory recess) can serve as signals for missing soft tissues. This methodology was tested on several dinosaur taxa. Restored airways in some taxa revealed the potential presence and likely shape of nasal turbinates. Heat transfer efficiency was tested in two dinosaur species with elaborated nasal passages. Results of that analysis revealed that dinosaur noses were efficient heat exchangers that likely played an integral role in maintaining cephalic thermoregulation. Brain cooling via nasal expansion appears to have been necessary for dinosaurs to have achieved their immense body sizes without overheating their brains.

  3. Prevalence of chronic obstructive pulmonary disease in asymptomatic smokers.

    PubMed

    Sansores, Raúl H; Velázquez-Uncal, Mónica; Pérez-Bautista, Oliver; Villalba-Caloca, Jaime; Falfán-Valencia, Ramcés; Ramírez-Venegas, Alejandra

    2015-01-01

    Physicians do not routinely recommend smokers to undergo spirometry unless they are symptomatic. To test the hypothesis that there are a significant number of asymptomatic smokers with chronic obstructive pulmonary disease (COPD), we estimated the prevalence of COPD in a group of asymptomatic smokers. Two thousand nine hundred and sixty-one smokers with a cumulative consumption history of at least 10 pack-years, either smokers with symptoms or smokers without symptoms (WOS) were invited to perform a spirometry and complete a symptom questionnaire. Six hundred and thirty-seven (21.5%) smokers had no symptoms, whereas 2,324 (78.5%) had at least one symptom. The prevalence of COPD in subjects WOS was 1.5% when considering the whole group of smokers (45/2,961) and 7% when considering only the group WOS (45/637). From 329 smokers with COPD, 13.7% were WOS. Subjects WOS were younger, had better lung function and lower cumulative consumption of cigarettes, estimated as both cigarettes per day and pack-years. According to severity of airflow limitation, 69% vs 87% of subjects were classified as Global Initiative for Chronic Obstructive Lung Disease stages I-II in the WOS and smokers with symptoms groups, respectively (P<0.001). A multivariate analysis showed that forced expiratory volume in 1 second (mL) was the only predictive factor for COPD in asymptomatic smokers. Prevalence of COPD in asymptomatic smokers is 1.5%. This number of asymptomatic smokers may be excluded from the benefit of an "early" intervention, not just pharmacological but also from smoking cessation counseling. The higher forced expiratory volume in 1 second may contribute to prevent early diagnosis.

  4. Chronic obstructive pulmonary disease and occupational exposure to silica.

    PubMed

    Rushton, Lesley

    2007-01-01

    Prolonged exposure to high levels of silica has long been known to cause silicosis This paper evaluates the evidence for an increased risk of chronic obstructive pulmonary disease (COPD) in occupations and industries in which exposure to crystalline silica is the primary exposure, with a focus on the magnitude of risks and levels of exposure causing disabling health effects. The literature suggests consistently elevated risks of developing COPD associated with silica exposure in several occupations, including the construction industry; tunneling; cement industry; brick manufacturing; pottery and ceramic work; silica sand, granite and diatomaceous earth industries; gold mining; and iron and steel founding, with risk estimates being high in some, even after taking into account the effect of confounders like smoking. Average dust levels vary from about 0.5 mg.m3 to over 10 mg.m3 and average silica levels from 0.04 to over 5 mg.m3, often well above occupational standards. Factors influencing the variation from industry to industry in risks associated with exposure to silica-containing dusts include (a) the presence of other minerals in the dust, particularly when associated with clay minerals; (b) the size of the particles and percentage of quartz; (c) the physicochemical characteristics, such as whether the dust is freshly fractured. Longitudinal studies suggest that loss of lung function occurs with exposure to silica dust at concentrations of between 0.1 and 0.2 mg.m3, and that the effect of cumulative silica dust exposure on airflow obstruction is independent of silicosis. Nevertheless, a disabling loss of lung function in the absence of silicosis would not occur until between 30 and 40 years exposure.

  5. Animal models of chronic obstructive pulmonary disease.

    PubMed

    Pérez-Rial, Sandra; Girón-Martínez, Álvaro; Peces-Barba, Germán

    2015-03-01

    Animal models of disease have always been welcomed by the scientific community because they provide an approach to the investigation of certain aspects of the disease in question. Animal models of COPD cannot reproduce the heterogeneity of the disease and usually only manage to represent the disease in its milder stages. Moreover, airflow obstruction, the variable that determines patient diagnosis, not always taken into account in the models. For this reason, models have focused on the development of emphysema, easily detectable by lung morphometry, and have disregarded other components of the disease, such as airway injury or associated vascular changes. Continuous, long-term exposure to cigarette smoke is considered the main risk factor for this disease, justifying the fact that the cigarette smoke exposure model is the most widely used. Some variations on this basic model, related to exposure time, the association of other inducers or inhibitors, exacerbations or the use of transgenic animals to facilitate the identification of pathogenic pathways have been developed. Some variations or heterogeneity of this disease, then, can be reproduced and models can be designed for resolving researchers' questions on disease identification or treatment responses. Copyright © 2014 SEPAR. Published by Elsevier Espana. All rights reserved.

  6. Airflow in Tracheobronchial Tree of Subjects with Tracheal Bronchus Simulated Using CT Image Based Models and CFD Method.

    PubMed

    Qi, Shouliang; Zhang, Baihua; Yue, Yong; Shen, Jing; Teng, Yueyang; Qian, Wei; Wu, Jianlin

    2018-03-01

    Tracheal Bronchus (TB) is a rare congenital anomaly characterized by the presence of an abnormal bronchus originating from the trachea or main bronchi and directed toward the upper lobe. The airflow pattern in tracheobronchial trees of TB subjects is critical, but has not been systemically studied. This study proposes to simulate the airflow using CT image based models and the computational fluid dynamics (CFD) method. Six TB subjects and three health controls (HC) are included. After the geometric model of tracheobronchial tree is extracted from CT images, the spatial distribution of velocity, wall pressure, wall shear stress (WSS) is obtained through CFD simulation, and the lobar distribution of air, flow pattern and global pressure drop are investigated. Compared with HC subjects, the main bronchus angle of TB subjects and the variation of volume are large, while the cross-sectional growth rate is small. High airflow velocity, wall pressure, and WSS are observed locally at the tracheal bronchus, but the global patterns of these measures are still similar to those of HC. The ratio of airflow into the tracheal bronchus accounts for 6.6-15.6% of the inhaled airflow, decreasing the ratio to the right upper lobe from 15.7-21.4% (HC) to 4.9-13.6%. The air into tracheal bronchus originates from the right dorsal near-wall region of the trachea. Tracheal bronchus does not change the global pressure drop which is dependent on multiple variables. Though the tracheobronchial trees of TB subjects present individualized features, several commonalities on the structural and airflow characteristics can be revealed. The observed local alternations might provide new insight into the reason of recurrent local infections, cough and acute respiratory distress related to TB.

  7. Experimental investigation into the interaction between the human body and room airflow and its effect on thermal comfort under stratum ventilation.

    PubMed

    Cheng, Y; Lin, Z

    2016-04-01

    Room occupants' comfort and health are affected by the airflow. Nevertheless, they themselves also play an important role in indoor air distribution. This study investigated the interaction between the human body and room airflow under stratum ventilation. Simplified thermal manikin was employed to effectively resemble the human body as a flow obstacle and/or free convective heat source. Unheated and heated manikins were designed to fully evaluate the impact of the manikin at various airflow rates. Additionally, subjective human tests were conducted to evaluate thermal comfort for the occupants in two rows. The findings show that the manikin formed a local blockage effect, but the supply airflow could flow over it. With the body heat from the manikin, the air jet penetrated farther compared with that for the unheated manikin. The temperature downstream of the manikin was also higher because of the convective effect. Elevating the supply airflow rate from 7 to 15 air changes per hour varied the downstream airflow pattern dramatically, from an uprising flow induced by body heat to a jet-dominated flow. Subjective assessments indicated that stratum ventilation provided thermal comfort for the occupants in both rows. Therefore, stratum ventilation could be applied in rooms with occupants in multiple rows. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Influence of airflow rate and substrate nature on heterogeneous struvite precipitation.

    PubMed

    Saidou, H; Ben Moussa, S; Ben Amor, M

    2009-01-01

    In wastewater treatment plants a hard scale consisting of struvite crystals can be formed, in pipes and recirculation pumps, during anaerobic digestion of wastewater. This study was conducted to evaluate the effect of airflow rate and substrate nature on nucleation type, induction period and supersaturation coefficient during struvite precipitation. A crystallization reactor similar to that designed for calcium carbonate precipitation was used. The pH of synthetic wastewater solution was increased by air bubbling. Experimental results indicated that the airflow increased heterogeneous precipitation of struvite. The susceptibility to scale formation was more important on polyamide and polyvinyl chloride than on stainless steel. In all cases, X-ray diffraction and infrared spectroscopy showed that the precipitated solid phase was solely struvite. No difference in crystal morphology was observed. However, at similar experimental conditions, the particle size of struvite was higher for stainless-steel material than that for plastic materials.

  9. Airflow and temperature distribution inside the maxillary sinus: a computational fluid dynamics simulation.

    PubMed

    Zang, Hongrui; Liu, Yingxi; Han, Demin; Zhang, Luo; Wang, Tong; Sun, Xiuzhen; Li, Lifeng

    2012-06-01

    The airflow velocity and flux in maxillary sinuses were much lower than those in the nasal cavity, and the temperature in maxillary sinuses was much higher than the temperature in the middle meatus. With the increase of maximum diameter of the ostium, the above indices changed little. The purpose of the paper was to investigate, first, the flow and temperature distribution inside normal maxillary sinus in inspiration, and second, flow and temperature alteration with the increase of maximum ostium diameter. Three-dimensional models with nasal cavities and bilateral maxillary sinuses were constructed for computational fluid dynamics analysis. Virtual surgeries were implemented for the maxillary ostium, the maximum diameters of which were 8, 10, 12, and 15 mm, respectively. The finite volume method was used for numerical simulation. The indices of velocity, pressure, vector, and temperature were processed and compared between models. The airflow velocity in maxillary sinuses (average velocity 0.062 m/s) was much lower than that in the middle meatus (average velocity 3.26 m/s). With the increase of ostium diameter, airflow characteristics distributed in the maxillary sinuses changed little. The normal temperature in the maxillary sinus remained almost constant at 34°C and changed little with the increase of ostium diameter.

  10. Differentiating between adductor and abductor spasmodic dysphonia using airflow interruption

    PubMed Central

    Hoffman, Matthew R.; Jiang, Jack J.; Rieves, Adam L.; McElveen, Kelsey A.B.; Ford, Charles N.

    2009-01-01

    Objective To measure the laryngeal resistance (RL), subglottal pressure (Ps), and mean flow rate (MFR) of adductor (ADSD) and abductor (ABSD) spasmodic dysphonia patients using the airflow interrupter. Methods The RL of six ABSD and seven ADSD patients was measured using the airflow interrupter, a noninvasive device designed to measure MFR and Ps via mechanical balloon valve interruption. Subjects performed ten trials at each of two intensity levels, with each trial consisting of a sustained /a/ during which phonation was interrupted for 500 ms. Laryngeal resistance was calculated as subglottal pressure divided by airflow. Results Mean RL for the ADSD and ABSD subtypes at 65 dB were 24.78 cmH2O/l/s and 14.51 cmH2O/l/s, respectively (p = 0.04). Mean RL at 70 dB were 40.02 cmH2O/l/s and 15.84 cmH2O/l/s (p = 0.014). Ps for the ADSD and ABSD subtypes at 65 dB were 10.23 cmH2O and 8.32 cmH2O, respectively (p = 0.582). At the 70 dB level, Ps were 12.39 cmH2O and 11.78 cmH2O (p = 0.886). MFR for the ADSD and ABSD subtypes at 65 dB were 435 ml/s and 746 ml/s (p = 0.205). Mean MFR at 70 dB were 518 ml/s and 848 ml/s (p = 0.198). Conclusion Noninvasive measurements of RL may be useful for differentiating between ADSD and ABSD. This simple objective test which produces a quantitative output could be used to evaluate laryngeal function in patients with spasmodic dysphonia. PMID:19554636

  11. Systems biology coupled with label-free high-throughput detection as a novel approach for diagnosis of chronic obstructive pulmonary disease

    PubMed Central

    Richens, Joanna L; Urbanowicz, Richard A; Lunt, Elizabeth AM; Metcalf, Rebecca; Corne, Jonathan; Fairclough, Lucy; O'Shea, Paul

    2009-01-01

    Chronic obstructive pulmonary disease (COPD) is a treatable and preventable disease state, characterised by progressive airflow limitation that is not fully reversible. Although COPD is primarily a disease of the lungs there is now an appreciation that many of the manifestations of disease are outside the lung, leading to the notion that COPD is a systemic disease. Currently, diagnosis of COPD relies on largely descriptive measures to enable classification, such as symptoms and lung function. Here the limitations of existing diagnostic strategies of COPD are discussed and systems biology approaches to diagnosis that build upon current molecular knowledge of the disease are described. These approaches rely on new 'label-free' sensing technologies, such as high-throughput surface plasmon resonance (SPR), that we also describe. PMID:19386108

  12. Respiration and heartbeat signal detection from airflow at airway in rat by catheter flow sensor with temperature compensation function

    NASA Astrophysics Data System (ADS)

    Hasegawa, Y.; Kawaoka, H.; Yamada, T.; Matsushima, M.; Kawabe, T.; Shikida, M.

    2017-12-01

    We previously proposed an evaluation method for detecting both respiration and heartbeat signals from the airflow at the mouth (Kawaoka et al 201518th Int. Conf. on Solid-State Sensors, Actuators and Microsystems; Kawaoka et al 2015 IEEE Sensors; Kawaoka et al 2016 Technical Digest IEEE Micro Electro Mechanical Systems Conf.). In the current study, we developed a catheter flow sensor with temperature compensation that uses MEMS technologies and used it to directly detect the breathing airflow in the airway of a rat. The temperature sensors were integrated with the catheter flow sensor. Heaters working as airflow and temperature sensors were produced on polymer film by using the same fabrication process so that the temperature coefficients of their resistances would coincide. As a result, the variation in sensor outputs due to the airflow temperature changes ranging from 20 °C to 34 °C was suppressed to less than 2.5%. The developed catheter flow sensor was inserted into the airway of a rat to detect both respiration and heartbeat signals. The accuracy of the breathing airflow measurements was improved thanks to the temperature compensation. The tidal volume variations between the expired and inspired air were suppressed to within 5%. Heartbeat signal information was extracted from the measured breathing waveforms by applying a discrete Fourier transform.

  13. External validation of ADO, DOSE, COTE and CODEX at predicting death in primary care patients with COPD using standard and machine learning approaches.

    PubMed

    Morales, Daniel R; Flynn, Rob; Zhang, Jianguo; Trucco, Emmanuel; Quint, Jennifer K; Zutis, Kris

    2018-05-01

    Several models for predicting the risk of death in people with chronic obstructive pulmonary disease (COPD) exist but have not undergone large scale validation in primary care. The objective of this study was to externally validate these models using statistical and machine learning approaches. We used a primary care COPD cohort identified using data from the UK Clinical Practice Research Datalink. Age-standardised mortality rates were calculated for the population by gender and discrimination of ADO (age, dyspnoea, airflow obstruction), COTE (COPD-specific comorbidity test), DOSE (dyspnoea, airflow obstruction, smoking, exacerbations) and CODEX (comorbidity, dyspnoea, airflow obstruction, exacerbations) at predicting death over 1-3 years measured using logistic regression and a support vector machine learning (SVM) method of analysis. The age-standardised mortality rate was 32.8 (95%CI 32.5-33.1) and 25.2 (95%CI 25.4-25.7) per 1000 person years for men and women respectively. Complete data were available for 54879 patients to predict 1-year mortality. ADO performed the best (c-statistic of 0.730) compared with DOSE (c-statistic 0.645), COTE (c-statistic 0.655) and CODEX (c-statistic 0.649) at predicting 1-year mortality. Discrimination of ADO and DOSE improved at predicting 1-year mortality when combined with COTE comorbidities (c-statistic 0.780 ADO + COTE; c-statistic 0.727 DOSE + COTE). Discrimination did not change significantly over 1-3 years. Comparable results were observed using SVM. In primary care, ADO appears superior at predicting death in COPD. Performance of ADO and DOSE improved when combined with COTE comorbidities suggesting better models may be generated with additional data facilitated using novel approaches. Copyright © 2018. Published by Elsevier Ltd.

  14. Arousal from sleep: implications for obstructive sleep apnea pathogenesis and treatment.

    PubMed

    Eckert, Danny J; Younes, Magdy K

    2014-02-01

    Historically, brief awakenings from sleep (cortical arousals) have been assumed to be vitally important in restoring airflow and blood-gas disturbances at the end of obstructive sleep apnea (OSA) breathing events. Indeed, in patients with blunted chemical drive (e.g., obesity hypoventilation syndrome) and in instances when other defensive mechanisms fail, cortical arousal likely serves an important protective role. However, recent insight into the pathogenesis of OSA indicates that a substantial proportion of respiratory events do not terminate with a cortical arousal from sleep. In many cases, cortical arousals may actually perpetuate blood-gas disturbances, breathing instability, and subsequent upper airway closure during sleep. This brief review summarizes the current understanding of the mechanisms mediating respiratory-induced cortical arousal, the physiological factors that influence the propensity for cortical arousal, and the potential dual roles that cortical arousal may play in OSA pathogenesis. Finally, the extent to which existing sedative agents decrease the propensity for cortical arousal and their potential to be therapeutically beneficial for certain OSA patients are highlighted.

  15. A Cross-sectional Assessment of Health-related Quality of Life among Patients with Chronic Obstructive Pulmonary Disease

    PubMed Central

    GARCIA-GORDILLO, Miguel Ángel; COLLADO-MATEO, Daniel; OLIVARES, Pedro Rufino; ADSUAR, José Carmelo; MERELLANO-NAVARRO, Eugenio

    2017-01-01

    Background: Chronic obstructive pulmonary disease (COPD) is a major cause of mortality characterized by progressive airflow obstruction and inflammation in the airways, which has an impact on health-related quality of life. The EQ-5D-5L is one of the most used preference-based, health-related quality of life questionnaire. The objective of this study was to provide normative values of EQ-5D-5L for Spanish people suffering from COPD. Methods: Data were extracted from the Spanish National Health Survey (2011/2012). Overall, 1130 people with COPD participated in this survey. The utility index of EQ-5D-5L and the Visual Analog Scale (VAS) score were defined by gender, region, and age. Results: Mean (SD) EQ-5D-5L utility index and VAS score for Spanish people with COPD were 0.742 (0.309) and 60.466 (21.934) respectively. In general, men reported better health status than women. Ceiling effect of the whole sample was 30.35%. Conclusion: The current study provides normative values of EQ-5D-5L for Spanish people affected by COPD. Ceiling effect was high and better results were observed in men compared with women. PMID:28894705

  16. The effect of airflow rates and aeration mode on the respiration activity of four organic wastes: Implications on the composting process.

    PubMed

    Mejias, Laura; Komilis, Dimitrios; Gea, Teresa; Sánchez, Antoni

    2017-07-01

    The aim of this study was to assess the effect of the airflow and of the aeration mode on the composting process of non-urban organic wastes that are found in large quantities worldwide, namely: (i) a fresh, non-digested, sewage sludge (FSS), (ii) an anaerobically digested sewage sludge (ADSS), (iii) cow manure (CM) and (iv) pig sludge (PS). This assessment was done using respirometric indices. Two aeration modes were tested, namely: (a) a constant air flowrate set at three different initial fixed airflow rates, and (b) an oxygen uptake rate (OUR)-controlled airflow rate. The four wastes displayed the same behaviour namely a limited biological activity at low aeration, while, beyond a threshold value, the increase of the airflow did not significantly increase the dynamic respiration indices (DRI 1 max , DRI 24 max and AT 4 ). The threshold airflow rate varied among wastes and ranged from 42NL air kg -1 DMh -1 for CM and from 67 to 77NL air kg -1 DMh -1 for FSS, ADSS and PS. Comparing the two aeration modes tested (constant air flow, OUR controlled air flow), no statistically significant differences were calculated between the respiration activity indices obtained at those two aeration modes. The results can be considered representative for urban and non-urban organic wastes and establish a general procedure to measure the respiration activity without limitations by airflow. This will permit other researchers to provide consistent results during the measurement of the respiration activity. Results indicate that high airflows are not required to establish the maximum respiration activity. This can result in energy savings and the prevention of off-gas treatment problems due to the excessive aeration rate in full scale composting plants. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Magnetic resonance imaging and computational fluid dynamics (CFD) simulations of rabbit nasal airflows for the development of hybrid CFD/PBPK models.

    PubMed

    Corley, R A; Minard, K R; Kabilan, S; Einstein, D R; Kuprat, A P; Harkema, J R; Kimbell, J S; Gargas, M L; Kinzell, John H

    2009-05-01

    The percentages of total airflows over the nasal respiratory and olfactory epithelium of female rabbits were calculated from computational fluid dynamics (CFD) simulations of steady-state inhalation. These airflow calculations, along with nasal airway geometry determinations, are critical parameters for hybrid CFD/physiologically based pharmacokinetic models that describe the nasal dosimetry of water-soluble or reactive gases and vapors in rabbits. CFD simulations were based upon three-dimensional computational meshes derived from magnetic resonance images of three adult female New Zealand White (NZW) rabbits. In the anterior portion of the nose, the maxillary turbinates of rabbits are considerably more complex than comparable regions in rats, mice, monkeys, or humans. This leads to a greater surface area to volume ratio in this region and thus the potential for increased extraction of water soluble or reactive gases and vapors in the anterior portion of the nose compared to many other species. Although there was considerable interanimal variability in the fine structures of the nasal turbinates and airflows in the anterior portions of the nose, there was remarkable consistency between rabbits in the percentage of total inspired airflows that reached the ethmoid turbinate region (approximately 50%) that is presumably lined with olfactory epithelium. These latter results (airflows reaching the ethmoid turbinate region) were higher than previous published estimates for the male F344 rat (19%) and human (7%). These differences in regional airflows can have significant implications in interspecies extrapolations of nasal dosimetry.

  18. Bladder outlet obstruction in women: definition and characteristics.

    PubMed

    Groutz, A; Blaivas, J G; Chaikin, D C

    2000-01-01

    The prevalence of bladder outlet obstruction in women is unknown and most probably has been underestimated. Moreover, there are no standard definitions for the diagnosis of bladder outlet obstruction in women. Our study was conducted to define as well as to examine the clinical and urodynamic characteristics of bladder outlet obstruction among women referred for evaluation of voiding symptoms. Bladder outlet obstruction was defined as a persistent, low, maximum "free" flow rate of <12 mL/s in repeated non-invasive uroflow studies, combined with high detrusor pressure at a maximum flow (p(det.Q)(max) >20 cm H(2)O) during detrusor pressure-uroflow studies. A urodynamic database of 587 consecutive women identified 38 (6.5%) women with bladder outlet obstruction. The mean age of the patients was 63.9 +/- 17.5 years. The mean maximum "free" flow, voided volume, and residual urinary volume were 9.4 +/-3.9 mL/s, 144. 9 +/- 72.7 mL, and 86.1 +/- 98.8 mL, respectively. The mean p(det. Q)(max) was 37.2 +/- 19.2 cm H(2)O. Previous anti-incontinence surgery and severe genital prolapse were the most common etiologies, accounting for half of the cases. Other, less common, etiologies included urethral stricture (13%), primary bladder neck obstruction (8%), learned voiding dysfunction (5%), and detrusor external sphincter dyssynergia (5%). Symptomatology was defined as mixed obstructive and irritative in 63% of the patients, isolated irritative in 29%, and isolated obstructive in other 8%. In conclusion, bladder outlet obstruction in women appears to be more common than was previously recognized, occurring in 6.5% of our patients. Micturition symptoms relevant to bladder outlet obstruction are non-specific, and a full urodynamic evaluation is essential in making the correct diagnosis and formulating a treatment plan.

  19. The protective effect of a beta 2 agonist against excessive airway narrowing in response to bronchoconstrictor stimuli in asthma and chronic obstructive lung disease.

    PubMed Central

    Bel, E. H.; Zwinderman, A. H.; Timmers, M. C.; Dijkman, J. H.; Sterk, P. J.

    1991-01-01

    Beta 2 agonists reduce airway hypersensitivity to bronchoconstrictor stimuli acutely in patients with asthma and chronic obstructive lung disease. To determine whether these drugs also protect against excessive airway narrowing, the effect of inhaled salbutamol on the position and shape of the dose-response curves for histamine or methacholine was investigated in 12 patients with asthma and 11 with chronic obstructive lung disease. After pretreatment with salbutamol (200 or 400 micrograms) or placebo in a double blind manner dose-response curves for inhaled histamine and methacholine were obtained by a standard method on six days in random order. Airway sensitivity was defined as the concentration of histamine or methacholine causing a 20% fall in FEV1 (PC20). A maximal response plateau on the log dose-response curve was considered to be present if two or more data points for FEV1 fell within a 5% response range. In the absence of a plateau, the test was continued until a predetermined level of severe bronchoconstriction was reached. Salbutamol caused an acute increase in FEV1 (mean increase 11.5% predicted in asthma, 7.2% in chronic obstructive lung disease), and increase in PC20 (mean 15 fold in asthma, fivefold in chronic obstructive lung disease), and an increase in the slope of the dose-response curves in both groups. In subjects in whom a plateau of FEV1 response could be measured salbutamol did not change the level of the plateau. In subjects without a plateau salbutamol did not lead to the development of a plateau, despite achieving a median FEV1 of 44% predicted in asthma and 39% in chronic obstructive lung disease. These results show that, although beta 2 agonists acutely reduce the airway response to a given strength of bronchoconstrictor stimulus, they do not protect against excessive airflow obstruction if there is exposure to relatively strong stimuli. This, together with the steepening of the dose-response curve, could be a disadvantage of beta 2

  20. Changes in Peak Airflow Measurement During Maximal Cough After Vocal Fold Augmentation in Patients With Glottic Insufficiency.

    PubMed

    Dion, Gregory R; Achlatis, Efstratios; Teng, Stephanie; Fang, Yixin; Persky, Michael; Branski, Ryan C; Amin, Milan R

    2017-11-01

    Compromised cough effectiveness is correlated with dysphagia and aspiration. Glottic insufficiency likely yields decreased cough strength and effectiveness. Although vocal fold augmentation favorably affects voice and likely improves cough strength, few data exist to support this hypothesis. To assess whether vocal fold augmentation improves peak airflow measurements during maximal-effort cough following augmentation. This case series study was conducted in a tertiary, academic laryngology clinic. Participants included 14 consecutive individuals with glottic insufficiency due to vocal fold paralysis, which was diagnosed via videostrobolaryngoscopy as a component of routine clinical examination. All participants who chose to proceed with augmentation were considered for the study whether office-based or operative augmentation was planned. Postaugmentation data were collected only at the first follow-up visit, which was targeted for 14 days after augmentation but varied on the basis of participant availability. Data were collected from June 5, 2014, to October 1, 2015. Data analysis took place between October 2, 2015, and March 3, 2017. Peak airflow during maximal volitional cough was quantified before and after vocal fold augmentation. Participants performed maximal coughs, and peak expiratory flow during the maximal cough was captured according to American Thoracic Society guidelines. Among the 14 participants (7 men and 7 women), the mean (SD) age was 62 (18) years. Three types of injectable material were used for vocal fold augmentation: carboxymethylcellulose in 5 patients, hyaluronic acid in 5, and calcium hydroxylapatite in 4. Following augmentation, cough strength increased in 11 participants and decreased cough strength was observed in 3. Peak airflow measurements during maximal cough varied from a decrease of 40 L/min to an increase of 150 L/min following augmentation. When preaugmentation and postaugmentation peak airflow measurements were compared, the

  1. Vapor-Generator Wand Helps To Reveal Airflow Patterns

    NASA Technical Reports Server (NTRS)

    Robelen, David B.

    1993-01-01

    In vapor-generator wand, liquid propylene glycol flows into electrically heated stainless-steel tube. Liquid boils in heated tube, and emerging vapor forms dense, smoke-like fog used to make airflow patterns visible. Built in variety of sizes, suitable for uses ranging from tabletop demonstrations to research in wind tunnels. For best viewing, plume illuminated by bright, focused incandescent spotlight at right angle to viewing direction. Viewing further enhanced by coating walls of test chamber with flat, dark color to minimize reflections and increase contrast.

  2. Periodontitis is related to lung volumes and airflow limitation: a cross-sectional study.

    PubMed

    Holtfreter, Birte; Richter, Stefanie; Kocher, Thomas; Dörr, Marcus; Völzke, Henry; Ittermann, Till; Obst, Anne; Schäper, Christoph; John, Ulrich; Meisel, Peter; Grotevendt, Anne; Felix, Stephan B; Ewert, Ralf; Gläser, Sven

    2013-12-01

    This study aimed to assess the potential association of periodontal diseases with lung volumes and airflow limitation in a general adult population. Based on a representative population sample of the Study of Health in Pomerania (SHIP), 1463 subjects aged 25-86 years were included. Periodontal status was assessed by clinical attachment loss (CAL), probing depth and number of missing teeth. Lung function was measured using spirometry, body plethysmography and diffusing capacity of the lung for carbon monoxide. Linear regression models using fractional polynomials were used to assess associations between periodontal disease and lung function. Fibrinogen and high-sensitivity C-reactive protein (hs-CRP) were evaluated as potential intermediate factors. After full adjustment for potential confounders mean CAL was significantly associated with variables of mobile dynamic and static lung volumes, airflow limitation and hyperinflation (p<0.05). Including fibrinogen and hs-CRP did not change coefficients of mean CAL; associations remained statistically significant. Mean CAL was not associated with total lung capacity and diffusing capacity of the lung for carbon monoxide. Associations were confirmed for mean probing depth, extent measures of CAL/probing depth and number of missing teeth. Periodontal disease was significantly associated with reduced lung volumes and airflow limitation in this general adult population sample. Systemic inflammation did not provide a mechanism linking both diseases.

  3. Pathogenesis of hyperinflation in chronic obstructive pulmonary disease

    PubMed Central

    Gagnon, Philippe; Guenette, Jordan A; Langer, Daniel; Laviolette, Louis; Mainguy, Vincent; Maltais, François; Ribeiro, Fernanda; Saey, Didier

    2014-01-01

    Chronic obstructive pulmonary disease (COPD) is a preventable and treatable lung disease characterized by airflow limitation that is not fully reversible. In a significant proportion of patients with COPD, reduced lung elastic recoil combined with expiratory flow limitation leads to lung hyperinflation during the course of the disease. Development of hyperinflation during the course of COPD is insidious. Dynamic hyperinflation is highly prevalent in the advanced stages of COPD, and new evidence suggests that it also occurs in many patients with mild disease, independently of the presence of resting hyperinflation. Hyperinflation is clinically relevant for patients with COPD mainly because it contributes to dyspnea, exercise intolerance, skeletal muscle limitations, morbidity, and reduced physical activity levels associated with the disease. Various pharmacological and nonpharmacological interventions have been shown to reduce hyperinflation and delay the onset of ventilatory limitation in patients with COPD. The aim of this review is to address the more recent literature regarding the pathogenesis, assessment, and management of both static and dynamic lung hyperinflation in patients with COPD. We also address the influence of biological sex and obesity and new developments in our understanding of hyperinflation in patients with mild COPD and its evolution during progression of the disease. PMID:24600216

  4. Airflow resistance and CO2 rebreathing properties of anti-asphyxia pillows designed for epilepsy.

    PubMed

    Catcheside, Peter G; Mohtar, Aaron A; Reynolds, Karen J

    2014-06-01

    Seizure related unconscious face-down positioning could contribute to sudden unexpected death in epilepsy via asphyxia. Low airflow resistance lattice foam pillows have been advocated for this group. However, data to support this approach remain lacking, and low airflow resistance per se may not negate asphyxia risk from expired gas rebreathing. This study was designed to compare the airflow resistance and CO2 rebreathing properties of lattice vs conventional pillows. Airflow resistance and inspired CO2 levels during replicate 10 min periods of simulated adult ventilation and CO2 rebreathing were compared between cotton, latex and two lattice pillows designed for use in epilepsy (one commercially available, one prototype). Kaplan-Meier and Cox regression analyses were used to examine the hazard of exceeding 10% inspired CO2 within 10-min of rebreathing. Inspiratory resistance was significantly lower in the commercially available and prototype lattice compared to cotton and latex pillows (mean±SD; 3.2±0.8, 2.6±0.4, 26.1±3.5, 4.6±0.4 cm H2O l(-1)s respectively at 0.2l s(-1)). During simulated rebreathing, inspired CO2 exceeded 10% within 2 min with cotton and latex pillows, compared to an upper asymptote around 8-9% at 10 min with lattice pillows. The hazard of exceeding 10% inspired CO2 was therefore markedly reduced with lattice compared to cotton and latex pillows (hazard ratio vs cotton pillow; commercial 0.04 [0.01-0.18], prototype 0.08 [0.02-0.26], latex 0.79 [0.33-1.87]). Conventional pillows can rapidly accumulate potentially life-threatening CO2 levels during simulated rebreathing. Lattice pillows appear to reduce asphyxia risk but accumulated CO2 may still reach levels threatening to health and survival. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  5. Inhaled indacaterol for the treatment of COPD patients with destroyed lung by tuberculosis and moderate-to-severe airflow limitation: results from the randomized INFINITY study.

    PubMed

    Kim, Cheong-Ju; Yoon, Hyoung-Kyu; Park, Myung-Jae; Yoo, Kwang-Ha; Jung, Ki-Suck; Park, Jeong-Woong; Lim, Seong Yong; Shim, Jae Jeong; Lee, Yong Chul; Kim, Young-Sam; Oh, Yeon-Mok; Kim, Song; Yoo, Chul-Gyu

    2017-01-01

    Pulmonary tuberculosis (TB) is a risk factor for chronic obstructive pulmonary disease (COPD); however, few clinical studies have investigated treatment effectiveness in COPD patients with destroyed lung by TB. The Indacaterol effectiveness in COPD patients with Tuberculosis history (INFINITY) study assessed the efficacy and safety of once-daily inhaled indacaterol 150 µg for the treatment of Korean COPD patients with destroyed lung by TB and moderate-to-severe airflow limitation. This was a multicenter, double-blind, parallel-group study, in which eligible patients were randomized (1:1) to receive either once-daily indacaterol 150 µg or placebo for 8 weeks. The primary efficacy endpoint was change from baseline in trough forced expiratory volume in 1 s at Week 8; the secondary endpoints included changes in transition dyspnea index score and St George's Respiratory Questionnaire for COPD score at Week 8. Safety was evaluated over 8 weeks. Of the 136 patients randomized, 119 (87.5%) completed the study treatment. At Week 8, indacaterol significantly improved trough forced expiratory volume in 1 s versus placebo (treatment difference [TD] 140 mL, P <0.001). Statistically significant improvement in transition dyspnea index score (TD =0.78, P <0.05) and numerical improvement in St George's Respiratory Questionnaire for COPD score (TD =-2.36, P =0.3563) were observed with indacaterol versus placebo at Week 8. Incidence of adverse events was comparable between the treatment groups. Indacaterol provided significantly superior bronchodilation, significant improvement in breathlessness and improved health status with comparable safety versus placebo in Korean COPD patients with destroyed lung by TB and moderate-to-severe airflow limitation.

  6. Inhaled indacaterol for the treatment of COPD patients with destroyed lung by tuberculosis and moderate-to-severe airflow limitation: results from the randomized INFINITY study

    PubMed Central

    Kim, Cheong-Ju; Yoon, Hyoung-Kyu; Park, Myung-Jae; Yoo, Kwang-Ha; Jung, Ki-Suck; Park, Jeong-Woong; Lim, Seong Yong; Shim, Jae Jeong; Lee, Yong Chul; Kim, Young-Sam; Oh, Yeon-Mok; Kim, Song; Yoo, Chul-Gyu

    2017-01-01

    Background and objective Pulmonary tuberculosis (TB) is a risk factor for chronic obstructive pulmonary disease (COPD); however, few clinical studies have investigated treatment effectiveness in COPD patients with destroyed lung by TB. The Indacaterol effectiveness in COPD patients with Tuberculosis history (INFINITY) study assessed the efficacy and safety of once-daily inhaled indacaterol 150 µg for the treatment of Korean COPD patients with destroyed lung by TB and moderate-to-severe airflow limitation. Methods This was a multicenter, double-blind, parallel-group study, in which eligible patients were randomized (1:1) to receive either once-daily indacaterol 150 µg or placebo for 8 weeks. The primary efficacy endpoint was change from baseline in trough forced expiratory volume in 1 s at Week 8; the secondary endpoints included changes in transition dyspnea index score and St George’s Respiratory Questionnaire for COPD score at Week 8. Safety was evaluated over 8 weeks. Results Of the 136 patients randomized, 119 (87.5%) completed the study treatment. At Week 8, indacaterol significantly improved trough forced expiratory volume in 1 s versus placebo (treatment difference [TD] 140 mL, P<0.001). Statistically significant improvement in transition dyspnea index score (TD =0.78, P<0.05) and numerical improvement in St George’s Respiratory Questionnaire for COPD score (TD =−2.36, P=0.3563) were observed with indacaterol versus placebo at Week 8. Incidence of adverse events was comparable between the treatment groups. Conclusion Indacaterol provided significantly superior bronchodilation, significant improvement in breathlessness and improved health status with comparable safety versus placebo in Korean COPD patients with destroyed lung by TB and moderate-to-severe airflow limitation. PMID:28615931

  7. Obstructed labour.

    PubMed

    Neilson, J P; Lavender, T; Quenby, S; Wray, S

    2003-01-01

    Obstructed labour is an important cause of maternal deaths in communities in which undernutrition in childhood is common resulting in small pelves in women, and in which there is no easy access to functioning health facilities with the capability of carrying out operative deliveries. Obstructed labour also causes significant maternal morbidity in the short term (notably infection) and long term (notably obstetric fistulas). Fetal death from asphyxia is also common. There are differences in the behaviour of the uterus during obstructed labour, depending on whether the woman has delivered previously. The pattern in primigravid women (typically diminishing contractility with risk of infection and fistula) may result from tissue acidosis, whereas in parous women, contractility may be maintained with the risk of uterine rupture. Ultimately, tackling the problem of obstructed labour will require universal adequate nutritional intake from childhood and the ability to access adequately equipped and staffed clinical facilities when problems arise in labour. These seem still rather distant aspirations. In the meantime, strategies should be implemented to encourage early recognition of prolonged labour and appropriate clinical responses. The sequelae of obstructed labour can be an enormous source of human misery and the prevention of obstetric fistulas, and skilled treatment if they do occur, are important priorities in regions where obstructed labour is still common.

  8. Prevalence of chronic obstructive pulmonary disease in asymptomatic smokers

    PubMed Central

    Sansores, Raúl H; Velázquez-Uncal, Mónica; Pérez-Bautista, Oliver; Villalba-Caloca, Jaime; Falfán-Valencia, Ramcés; Ramírez-Venegas, Alejandra

    2015-01-01

    Background Physicians do not routinely recommend smokers to undergo spirometry unless they are symptomatic. Objective To test the hypothesis that there are a significant number of asymptomatic smokers with chronic obstructive pulmonary disease (COPD), we estimated the prevalence of COPD in a group of asymptomatic smokers. Methods Two thousand nine hundred and sixty-one smokers with a cumulative consumption history of at least 10 pack-years, either smokers with symptoms or smokers without symptoms (WOS) were invited to perform a spirometry and complete a symptom questionnaire. Results Six hundred and thirty-seven (21.5%) smokers had no symptoms, whereas 2,324 (78.5%) had at least one symptom. The prevalence of COPD in subjects WOS was 1.5% when considering the whole group of smokers (45/2,961) and 7% when considering only the group WOS (45/637). From 329 smokers with COPD, 13.7% were WOS. Subjects WOS were younger, had better lung function and lower cumulative consumption of cigarettes, estimated as both cigarettes per day and pack-years. According to severity of airflow limitation, 69% vs 87% of subjects were classified as Global Initiative for Chronic Obstructive Lung Disease stages I–II in the WOS and smokers with symptoms groups, respectively (P<0.001). A multivariate analysis showed that forced expiratory volume in 1 second (mL) was the only predictive factor for COPD in asymptomatic smokers. Conclusion Prevalence of COPD in asymptomatic smokers is 1.5%. This number of asymptomatic smokers may be excluded from the benefit of an “early” intervention, not just pharmacological but also from smoking cessation counseling. The higher forced expiratory volume in 1 second may contribute to prevent early diagnosis. PMID:26586941

  9. Use of videoendoscopy during exercise for determination of appropriate surgical treatment of laryngeal hemiplegia in a colt.

    PubMed

    Stick, J A; Derksen, F J

    1989-09-01

    Videoendoscopy of the larynx during treadmill exercise was used to determine the surgical treatment of upper airway obstruction in a Standardbred colt. Surgical correction of right-sided laryngeal hemiplegia, first by laryngoplasty, then subtotal arytenoidectomy, was ineffective. Videoendoscopy indicated, and upper airway flow mechanics confirmed, that the laryngeal opening was adequate at rest, but obstruction occurred during exercise. On the basis of the appearance of the larynx during high airflow rates on slow-motion playback of the videorecording, total arytenoidectomy was performed, which permitted the horse to race successfully. Videoendoscopy of the upper airway during exercise accurately predicted airflow impedance and permitted salvage of this racehorse, indicating that this is a practical, useful technique that will improve evaluation of upper airway obstructions in the horse.

  10. Urinary obstruction is an important complicating factor in patients with septic shock due to urinary infection.

    PubMed

    Reyner, Karina; Heffner, Alan C; Karvetski, Colleen H

    2016-04-01

    Urinary tract infection (UTI) is a common cause of severe sepsis, and anatomic urologic obstruction is a recognized factor for complicated disease. We aimed to identify the incidence of urinary obstruction complicating acute septic shock and determine the characteristics and outcomes of this group. Patients prospectively enrolled in a sepsis treatment pathway registry between October 2013 and July 2014 were reviewed for the diagnosis of UTI. Standardized medical record review was performed to confirm sepsis due to UTI and determine clinical variables including the presence of anatomic urinary obstruction. Patients with septic shock due to UTI with obstruction were compared with those without obstruction. The primary outcomes were incidence of urinary obstruction and hospital mortality. Among 1084 registry enrollees, 209 (19.2%) met inclusion criteria for the study. Acute anatomic obstruction was identified in 22 (10.5%) patients. Hospital mortality in patients with obstruction was 27.3% compared with 11.2% in patients without obstruction (absolute difference of 16.1%; P = .03; 95% confidence interval [CI], 1.2%-30.9%). Hospital length of stay among survivors was 12.8 days compared with 8.3 days (absolute difference of 4.5 days; P = .04; 95% CI, 0.2-8.8 days). History of urinary stone disease was independently associated with obstruction (odds ratio, 5.6; 95% CI, 2.2-14.3). Approximately 1 in 10 patients presenting with septic shock due to a urinary source is complicated by anatomic urinary obstruction. These patients have significantly higher mortality compared with patients without obstruction. Early imaging of patients with septic shock due to suspected urinary source should be considered to identify obstruction requiring emergency intervention. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Obstructive Sleep Apnea: A Cluster Analysis at Time of Diagnosis

    PubMed Central

    Grillet, Yves; Richard, Philippe; Stach, Bruno; Vivodtzev, Isabelle; Timsit, Jean-Francois; Lévy, Patrick; Tamisier, Renaud; Pépin, Jean-Louis

    2016-01-01

    Background The classification of obstructive sleep apnea is on the basis of sleep study criteria that may not adequately capture disease heterogeneity. Improved phenotyping may improve prognosis prediction and help select therapeutic strategies. Objectives: This study used cluster analysis to investigate the clinical clusters of obstructive sleep apnea. Methods An ascending hierarchical cluster analysis was performed on baseline symptoms, physical examination, risk factor exposure and co-morbidities from 18,263 participants in the OSFP (French national registry of sleep apnea). The probability for criteria to be associated with a given cluster was assessed using odds ratios, determined by univariate logistic regression. Results: Six clusters were identified, in which patients varied considerably in age, sex, symptoms, obesity, co-morbidities and environmental risk factors. The main significant differences between clusters were minimally symptomatic versus sleepy obstructive sleep apnea patients, lean versus obese, and among obese patients different combinations of co-morbidities and environmental risk factors. Conclusions Our cluster analysis identified six distinct clusters of obstructive sleep apnea. Our findings underscore the high degree of heterogeneity that exists within obstructive sleep apnea patients regarding clinical presentation, risk factors and consequences. This may help in both research and clinical practice for validating new prevention programs, in diagnosis and in decisions regarding therapeutic strategies. PMID:27314230

  12. Hybridized electromagnetic-triboelectric nanogenerator for scavenging air-flow energy to sustainably power temperature sensors.

    PubMed

    Wang, Xue; Wang, Shuhua; Yang, Ya; Wang, Zhong Lin

    2015-04-28

    We report a hybridized nanogenerator with dimensions of 6.7 cm × 4.5 cm × 2 cm and a weight of 42.3 g that consists of two triboelectric nanogenerators (TENGs) and two electromagnetic generators (EMGs) for scavenging air-flow energy. Under an air-flow speed of about 18 m/s, the hybridized nanogenerator can deliver largest output powers of 3.5 mW for one TENG (in correspondence of power per unit mass/volume: 8.8 mW/g and 14.6 kW/m(3)) at a loading resistance of 3 MΩ and 1.8 mW for one EMG (in correspondence of power per unit mass/volume: 0.3 mW/g and 0.4 kW/m(3)) at a loading resistance of 2 kΩ, respectively. The hybridized nanogenerator can be utilized to charge a capacitor of 3300 μF to sustainably power four temperature sensors for realizing self-powered temperature sensor networks. Moreover, a wireless temperature sensor driven by a hybridized nanogenerator charged Li-ion battery can work well to send the temperature data to a receiver/computer at a distance of 1.5 m. This work takes a significant step toward air-flow energy harvesting and its potential applications in self-powered wireless sensor networks.

  13. Analysis of obstruction site in obstructive sleep apnea syndrome patients by drug induced sleep endoscopy.

    PubMed

    Koo, Soo Kweon; Choi, Jang Won; Myung, Nam Suk; Lee, Hyoung Ju; Kim, Yang Jae; Kim, Young Joong

    2013-01-01

    We analyzed site, pattern and degree of obstruction in Korean male obstructive sleep apnea syndrome (OSAS) patients by drug-induced sleep endoscopy (DISE). We also investigated possible links between BMI, AHI and DISE findings. Sixty-nine male patients underwent DISE. DISE findings were reported using our classification system in which modified 'VOTE classification' - obstruction type, site of obstruction, degree of obstruction and anatomical site contributing obstruction - was reported. Associations were analyzed among the results of the polysomnography, patients' characteristics and DISE finding. Multilevel airway obstruction was found in 84.06% of patients and 15.94% had a unilevel obstruction. Among those with unilevel obstruction, 90.90% had retropalatal level obstruction and 9.10% had retrolingual level obstruction. Palate with lateral pharyngeal wall obstruction (49.28%) is the most common obstruction type of the retropalatal level and tongue with lateral pharyngeal wall (37.68%) is the most common obstruction type of the retrolingual level. Examining the relation between obstruction site according to body mass index (BMI) and severity of OSAS (apnea hypopnea index, AHI), the lateral pharyngeal wall had an increasing tendency associated with higher BMI and higher AHI. But the lateral pharyngeal wall of both levels was statistically significant associated with higher AHI. The majority of the Korean male OSAS patients have multilevel obstruction and according to BMI and AHI, the DISE findings indicate that the lateral pharyngeal wall is the most important anatomical site contributing to obstruction regardless of the level at which the obstruction lies. © 2013 Elsevier Inc. All rights reserved.

  14. Unicentric study of cell therapy in chronic obstructive pulmonary disease/pulmonary emphysema

    PubMed Central

    Ribeiro-Paes, João Tadeu; Bilaqui, Aldemir; Greco, Oswaldo T; Ruiz, Milton Artur; Marcelino, Monica Y; Stessuk, Talita; de Faria, Carolina A; Lago, Mario R

    2011-01-01

    Within the chronic obstructive pulmonary disease (COPD) spectrum, lung emphysema presents, as a primarily histopathologic feature, the destruction of pulmonary parenchyma and, accordingly, an increase in the airflow obstruction distal to the terminal bronchiole. Notwithstanding the significant advances in prevention and treatment of symptoms, no effective or curative therapy has been accomplished. In this context, cellular therapy with stem cells (SCs) arises as a new therapeutic approach, with a wide application potential. The purpose of this study is to evaluate the safety of SCs infusion procedure in patients with advanced COPD (stage IV dyspnea). After selection, patients underwent clinical examination and received granulocyte colony-stimulating factor, immediately prior to the bone marrow harvest. The bone marrow mononuclear cells (BMMC) were isolated and infused into a peripheral vein. The 12-month follow-up showed a significant improvement in the quality of life, as well as a clinical stable condition, which suggest a change in the natural process of the disease. Therefore, the proposed methodology in this study for BMMC cell therapy in sufferers of advanced COPD was demonstrated to be free of significant adverse effects. Although a larger sample and a greater follow-up period are needed, it is possible to infer that BMMC cell therapy introduces an unprecedented change in the course or in the natural history of emphysema, inhibiting or slowing the progression of disease. This clinical trial was registered with ClinicalTrials.gov (NCT01110252) and was approved by the Brazilian National Committee of Ethics in Research (registration no. 14764, CONEP report 233/2009). PMID:21311694

  15. A New Approach for Identifying Patients with Undiagnosed Chronic Obstructive Pulmonary Disease

    PubMed Central

    Mannino, David; Leidy, Nancy Kline; Malley, Karen G.; Bacci, Elizabeth D.; Barr, R. Graham; Bowler, Russ P.; Han, MeiLan K.; Houfek, Julia F.; Make, Barry; Meldrum, Catherine A.; Rennard, Stephen; Thomashow, Byron; Walsh, John; Yawn, Barbara P.

    2017-01-01

    Rationale: Chronic obstructive pulmonary disease (COPD) is often unrecognized and untreated. Objectives: To develop a method for identifying undiagnosed COPD requiring treatment with currently available therapies (FEV1 <60% predicted and/or exacerbation risk). Methods: We conducted a multisite, cross-sectional, case-control study in U.S. pulmonary and primary care clinics that recruited subjects from primary care settings. Cases were patients with COPD and at least one exacerbation in the past year or FEV1 less than 60% of predicted without exacerbation in the past year. Control subjects were persons with no COPD or with mild COPD (FEV1 ≥60% predicted, no exacerbation in the past year). In random forests analyses, we identified the smallest set of questions plus peak expiratory flow (PEF) with optimal sensitivity (SN) and specificity (SP). Measurements and Main Results: PEF and spirometry were recorded in 186 cases and 160 control subjects. The mean (SD) age of the sample population was 62.7 (10.1) years; 55% were female; 86% were white; and 16% had never smoked. The mean FEV1 percent predicted for cases was 42.5% (14.2%); for control subjects, it was 82.5% (15.7%). A five-item questionnaire, CAPTURE (COPD Assessment in Primary Care to Identify Undiagnosed Respiratory Disease and Exacerbation Risk), was used to assess exposure, breathing problems, tiring easily, and acute respiratory illnesses. CAPTURE exhibited an SN of 95.7% and an SP of 44.4% for differentiating cases from all control subjects, and an SN of 95.7% and an SP of 67.8% for differentiating cases from no-COPD control subjects. The PEF (males, <350 L/min; females, <250 L/min) SN and SP were 88.0% and 77.5%, respectively, for differentiating cases from all control subjects, and they were 88.0% and 90.8%, respectively, for distinguishing cases from no-COPD control subjects. The CAPTURE plus PEF exhibited improved SN and SP for all cases versus all control subjects (89.7% and 78.1%, respectively) and

  16. Response characteristics for thermal and pressure devices commonly used for monitoring nasal and oral airflow during sleep studies.

    PubMed

    Gehring, J M; Cho, J-G; Wheatley, J R; Amis, T C

    2014-03-01

    We examined thermocouple and pressure cannulae responses to oral and nasal airflow using a polyester model of a human face, with patent nasal and oral orifices instrumented with a dual thermocouple (F-ONT2A, Grass) or a dual cannula (0588, Braebon) pressure transducer (± 10 cm H2O, Celesco) system. Tidal airflow was generated using a dual compartment facemask with pneumotachographs (Fleisch 2) connected to the model orifices. During nasal breathing: thermocouple amplitude = 0.38 Ln [pneumotachograph amplitude] + 1.31 and pressure cannula amplitude = 0.93 [pneumotachograph amplitude](2.15); during oral breathing: thermocouple amplitude = 0.44 Ln [pneumotachograph amplitude] + 1.07 and pressure cannula amplitude = 0.33 [pneumotachograph amplitude](1.72); (all range ∼ 0.1-∼ 4.0 L s(-1); r(2) > 0.7). For pneumotachograph amplitudes <1 L s(-1) (linear model) change in thermocouple amplitude/unit change in pneumotachograph amplitude was similar for nasal and oral airflow, whereas nasal pressure cannula amplitude/unit change in pneumotachograph amplitude was almost four times that for oral. Increasing oral orifice area from 0.33 cm(2) to 2.15 cm(2) increased oral thermocouple amplitude/unit change in pneumotachograph amplitude by ∼ 58% but decreased pressure cannula amplitude/unit change in pneumotachograph amplitude by 49%. For pneumotachograph amplitudes up to 1 L s(-1), alterations in inspiratory/expiratory ratios or total respiratory time did not affect the sensitivity of either nasal or oral pressure cannulae or the nasal thermocouple, but the oral thermocouple sensitivity was influenced by respiratory cycle time. Different nasal and oral responses influence the ability of these systems to quantitatively assess nasal and oral airflow and oro-nasal airflow partitioning.

  17. Airflow-terrain interactions through a mountain gap, with an example of eolian activity beneath an atmospheric hydraulic jump

    NASA Astrophysics Data System (ADS)

    Gaylord, David R.; Dawson, Paul J.

    1987-09-01

    The integration of atmospheric soundings from a fully instrumented aircraft with detailed sedimentary and geomorphic analyses of eolian features in the Ferris dune field of south-central Wyoming lends insight into the manner in which topography interacts with airflow to modify eolian activity. Topographically modified airflow results in zones of airflow deceleration, acceleration, and enhanced atmospheric turbulence, all of which influence the surface morphology and sedimentology. Extreme lateral confluence of prevailing airflow produces accelerated, unidirectional winds. These winds correlate with unusually continuous and elongate parabolic dunes that extend into a mountain gap (Windy Gap). Persistently heightened winds produced at the entrance to Windy Gap have resulted in a concentration of active sand dunes that lack slipfaces. Common development of a strongly amplified atmospheric wave analogous to a hydraulic jump in the gap contributes to the formation of a variety of eolian features that mantle the surface of Windy Gap and the Ferris dune field tail. Heightened, unidirectional winds in this zone promote grain-size segregation, the formation of elongated and aligned sand drifts, climbing and falling dunes, elongate scour streaks, and parabolic dunes that have low-angle (<20°) cross-stratification. Deflation of bedrock and loose sediment has been enhanced in the zone of maximum turbulence beneath the hydraulic jump.

  18. Distributed porous throat stability bypass to increase the stable airflow range of a Mach 2.5 inlet with 60 percent internal contraction

    NASA Technical Reports Server (NTRS)

    Shaw, R. J.; Mitchell, G. A.; Sanders, B. W.

    1974-01-01

    The results of an experimental investigation to increase the stable airflow operating range of a supersonic, mixed-compression inlet with 60-percent internal contraction are presented. Various distributed-porous, throat stability-bypass entrance configurations were tested. In terms of diffuser-exit corrected airflow, a large inlet stable airflow range of about 25 percent was obtained with the optimum configuration if a constant pressure was maintained in the by-pass plenum. The location of the centerbody bleed region had a decided effect on the overall inlet performance. Limited unstart angle-of-attack data are presented.

  19. A smart, intermittent driven particle sensor with an airflow change trigger using a lead zirconate titanate (PZT) cantilever

    NASA Astrophysics Data System (ADS)

    Takahashi, Hidetoshi; Tomimatsu, Yutaka; Kobayashi, Takeshi; Isozaki, Akihiro; Itoh, Toshihiro; Maeda, Ryutaro; Matsumoto, Kiyoshi; Shimoyama, Isao

    2014-02-01

    This paper reports on a smart, intermittent driven particle sensor with an airflow trigger. A lead zirconate titanate cantilever functions as the trigger, which detects an airflow change without requiring a power supply to drive the sensing element. Because an airflow change indicates that the particle concentration has changed, the trigger switches the optical particle counter from sleep mode to active mode only when the particle concentration surrounding the sensor changes. The sensor power consumption in sleep mode is 100 times less than that in the active mode. Thus, this intermittent driven method significantly reduces the total power consumption of the particle sensor. In this paper, we fabricate a prototype of the particle sensor and demonstrate that the optical particle counter can be switched on by the fabricated trigger and thus that the particle concentration can be measured.

  20. Impacts of Fluid Dynamics Simulation in Study of Nasal Airflow Physiology and Pathophysiology in Realistic Human Three-Dimensional Nose Models

    PubMed Central

    Lee, Heow Peuh; Gordon, Bruce R.

    2012-01-01

    During the past decades, numerous computational fluid dynamics (CFD) studies, constructed from CT or MRI images, have simulated human nasal models. As compared to rhinomanometry and acoustic rhinometry, which provide quantitative information only of nasal airflow, resistance, and cross sectional areas, CFD enables additional measurements of airflow passing through the nasal cavity that help visualize the physiologic impact of alterations in intranasal structures. Therefore, it becomes possible to quantitatively measure, and visually appreciate, the airflow pattern (laminar or turbulent), velocity, pressure, wall shear stress, particle deposition, and temperature changes at different flow rates, in different parts of the nasal cavity. The effects of both existing anatomical factors, as well as post-operative changes, can be assessed. With recent improvements in CFD technology and computing power, there is a promising future for CFD to become a useful tool in planning, predicting, and evaluating outcomes of nasal surgery. This review discusses the possibilities and potential impacts, as well as technical limitations, of using CFD simulation to better understand nasal airflow physiology. PMID:23205221

  1. The effects of a hot drink on nasal airflow and symptoms of common cold and flu.

    PubMed

    Sanu, A; Eccles, R

    2008-12-01

    Hot drinks are a common treatment for common cold and flu but there are no studies reported in the scientific and clinical literature on this mode of treatment. This study investigated the effects of a hot fruit drink on objective and subjective measures of nasal airflow, and on subjective scores for common cold/flu symptoms in 30 subjects suffering from common cold/flu. The results demonstrate that the hot drink had no effect on objective measurement of nasal airflow but it did cause a significant improvement in subjective measures of nasal airflow. The hot drink provided immediate and sustained relief from symptoms of runny nose, cough, sneezing, sore throat, chilliness and tiredness, whereas the same drink at room temperature only provided relief from symptoms of runny nose, cough and sneezing. The effects of the drinks are discussed in terms of a placebo effect and physiological effects on salivation and airway secretions. In conclusion the results support the folklore that a hot tasty drink is a beneficial treatment for relief of most symptoms of common cold and flu.

  2. Study on airflow characteristics of rear wing of F1 car

    NASA Astrophysics Data System (ADS)

    Azmi, A. R. S.; Sapit, A.; Mohammed, A. N.; Razali, M. A.; Sadikin, A.; Nordin, N.

    2017-09-01

    The paper aims to investigate CFD simulation is carried out to investigate the airflow along the rear wing of F1 car with Reynold number of 3 × 106 and velocity, u = 43.82204 m/s. The analysis was done using 2-D model consists of main plane and flap wing, combined together to form rear wing module. Both of the aerofoil is placed inside a box of 350mm long and 220mm height according to regulation set up by FIA. The parameters for this study is the thickness and the chord length of the flap wing aerofoil. The simulations were performed by using FLUENT solver and k-kl-omega model. The wind speed is set up to 43 m/s that is the average speed of F1 car when cornering. This study uses NACA 2408, 2412, and 2415 for the flap wing and BE50 for the main plane. Each cases being simulated with a gap between the aerofoil of 10mm and 50mm when the DRS is activated. Grid independence test and validation was conduct to make sure the result obtained is acceptable. The goal of this study is to investigate aerodynamic behavior of airflow around the rear wing as well as to see how the thickness and the chord length of flap wing influence the airflow at the rear wing. The results show that increasing in thickness of the flap wing aerofoil will decreases the downforce. The results also show that although the short flap wing generate lower downforce than the big flap wing, but the drag force can be significantly reduced as the short flap wing has more change in angle of attack when it is activated. Therefore, the type of aerofoil for the rear wing should be decided according to the circuit track so that it can be fully optimized.

  3. Burden of obstructive lung disease in a rural setting in the Philippines.

    PubMed

    Idolor, Luisito F; DE Guia, Teresita S; Francisco, Norberto A; Roa, Camilo C; Ayuyao, Fernando G; Tady, Cecil Z; Tan, Daniel T; Banal-Yang, Sylvia; Balanag, Vincent M; Reyes, Maria Teresita N; Dantes, Renato B

    2011-10-01

    The aim of this study was to determine the prevalence of and risk factors associated with COPD in a rural setting in the Philippines. The study was conducted in two municipalities in Nueva Ecija province in the Philippines. Using the Burden of Obstructive Lung Disease (BOLD) protocol and study design, non-hospitalized men or women, aged 40years or older, were recruited by multi-stage random sampling procedures. Participants completed questionnaires on respiratory symptoms and exposure to potential risk factors for COPD, including smoking, occupation and exposure to burning of biomass fuel. Spirometry was performed according to American Thoracic Society criteria. Of the 1188 individuals selected for recruitment, 722 had acceptable post-bronchodilator spirometry and were classified according to Global Initiative for Chronic Obstructive Lung Disease (GOLD) stage. The overall prevalence of COPD for all stages was 20.8%. The prevalence of COPD at GOLD Stage I or higher was greater in men compared with women (26.5% vs 15.3%), and increased between the ages of 40 to >70years. Logistic regression analysis showed a significant association between all stages of COPD and farming for >40years (odds ratio (OR) 2.48, 95% confidence interval (CI): 1.43-4.30), use of firewood for cooking for >60years (OR 3.48, 95% CI: 1.57-7.71), a smoking history of ≥20 pack-years (OR 2.86; 95% CI: 1.78-4.60), and a history of tuberculosis (OR 6.31, 95% CI: 2.67-15.0). The prevalence COPD in a rural community in Nueva Ecija, Philippines was 20.8% for GOLD Stage I or higher, and 16.7% for GOLD Stage II or higher. In addition to smoking history, the use of firewood for cooking, working on a farm and a history of tuberculosis were significantly associated with fixed airflow obstruction, as assessed by spirometry. © 2011 The Authors. Respirology © 2011 Asian Pacific Society of Respirology.

  4. Alterations of the arginine metabolome in asthma.

    PubMed

    Lara, Abigail; Khatri, Sumita B; Wang, Zeneng; Comhair, Suzy A A; Xu, Weiling; Dweik, Raed A; Bodine, Melanie; Levison, Bruce S; Hammel, Jeffrey; Bleecker, Eugene; Busse, William; Calhoun, William J; Castro, Mario; Chung, Kian Fan; Curran-Everett, Douglas; Gaston, Benjamin; Israel, Elliot; Jarjour, Nizar; Moore, Wendy; Peters, Stephen P; Teague, W Gerald; Wenzel, Sally; Hazen, Stanley L; Erzurum, Serpil C

    2008-10-01

    As the sole nitrogen donor in nitric oxide (NO) synthesis and key intermediate in the urea cycle, arginine and its metabolic pathways are integrally linked to cellular respiration, metabolism, and inflammation. We hypothesized that arginine (Arg) bioavailability would be associated with airflow abnormalities and inflammation in subjects with asthma, and would be informative for asthma severity. Arg bioavailability was assessed in subjects with severe and nonsevere asthma and healthy control subjects by determination of plasma Arg relative to its metabolic products, ornithine and citrulline, and relative to methylarginine inhibitors of NO synthases, and by serum arginase activity. Inflammatory parameters, including fraction of exhaled NO (Fe(NO)), IgE, skin test positivity to allergens, bronchoalveolar lavage, and blood eosinophils, were also evaluated. Subjects with asthma had greater Arg bioavailability, but also increased Arg catabolism compared with healthy control subjects, as evidenced by higher levels of Fe(NO) and serum arginase activity. However, Arg bioavailability was positively associated with Fe(NO) only in healthy control subjects; Arg bioavailability was unrelated to Fe(NO) or other inflammatory parameters in severe or nonsevere asthma. Inflammatory parameters were related to airflow obstruction and reactivity in nonsevere asthma, but not in severe asthma. Conversely, Arg bioavailability was related to airflow obstruction in severe asthma, but not in nonsevere asthma. Modeling confirmed that measures of Arg bioavailabilty predict airflow obstruction only in severe asthma. Unlike Fe(NO), Arg bioavailability is not a surrogate measure of inflammation; however, Arg bioavailability is strongly associated with airflow abnormalities in severe asthma.

  5. Virtual surgery for patients with nasal obstruction: Use of computational fluid dynamics (MeComLand®, Digbody® & Noseland®) to document objective flow parameters and optimise surgical results.

    PubMed

    Burgos, Manuel A; Sevilla García, Maria Agustina; Sanmiguel Rojas, Enrique; Del Pino, Carlos; Fernández Velez, Carlos; Piqueras, Francisco; Esteban Ortega, Francisco

    Computational fluid dynamics (CFD) is a mathematical tool to analyse airflow. We present a novel CFD software package to improve results following nasal surgery for obstruction. A group of engineers in collaboration with otolaryngologists have developed a very intuitive CFD software package called MeComLand®, which uses the patient's cross-sectional (tomographic) images, thus showing in detail results originated by CFD such as airflow distributions, velocity profiles, pressure, or wall shear stress. NOSELAND® helps medical evaluation with dynamic reports by using a 3D endoscopic view. Using this CFD-based software a patient underwent virtual surgery (septoplasty, turbinoplasty, spreader grafts, lateral crural J-flap and combinations) to choose the best improvement in nasal flow. To present a novel software package to improve nasal surgery results. To apply the software on CT slices from a patient affected by septal deviation. To evaluate several surgical procedures (septoplasty, turbinectomy, spreader-grafts, J-flap and combination among them) to find the best alternative with less morbidity. The combination of all the procedures does not provide the best nasal flow improvement. Septoplasty plus turbinoplasty obtained the best results. Turbinoplasty alone rendered almost similar results to septoplasty in our simulation. CFD provides useful complementary information to cover diagnosis, prognosis, and follow-up of nasal pathologies based on quantitative magnitudes linked to fluid flow. MeComLand®, DigBody® and NoseLand® represent a non-invasive, low-cost alternative for the functional study of patients with nasal obstruction. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  6. Mitral stenosis and hypertrophic obstructive cardiomyopathy: An unusual combination.

    PubMed

    Hong, Joonhwa; Schaff, Hartzell V; Ommen, Steve R; Abel, Martin D; Dearani, Joseph A; Nishimura, Rick A

    2016-04-01

    Systolic anterior motion of mitral valve (MV) leaflets is a main pathophysiologic feature of left ventricular outflow tract (LVOT) obstruction in hypertrophic obstructive cardiomyopathy. Thus, restricted leaflet motion that occurs with MV stenosis might be expected to minimize outflow tract obstruction related to systolic anterior motion. From January 1993 through February 2015, we performed MV replacement and septal myectomy in 12 patients with mitral stenosis and hypertrophic obstructive cardiomyopathy at Mayo Clinic Hospital in Rochester, Minn. Preoperative data, echocardiographic images, operative records, and postoperative outcomes were reviewed. Mean (standard deviation) age was 70 (7.6) years. Preoperative mean (standard deviation) maximal LVOT pressure gradient was 75.0 (35.0) mm Hg; MV gradient was 13.7 (2.8) mm Hg. From echocardiographic images, 4 mechanisms of outflow tract obstruction were identified: systolic anterior motion without severe limitation in MV leaflet excursion, severe limitation in MV leaflet mobility with systolic anterior motion at the tip of the MV anterior leaflet, septal encroachment toward the LVOT, and MV displacement toward the LVOT by calcification. Mitral valve replacement and extended septal myectomy relieved outflow gradients in all patients, with no death or serious morbidity. Patients with mitral stenosis and hypertrophic obstructive cardiomyopathy have multiple LVOT obstruction mechanisms, and MV replacement may not be adequate treatment. We favor septal myectomy and MV replacement in this complex subset of hypertrophic obstructive cardiomyopathy. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  7. Predictors of Hospitalized Exacerbations and Mortality in Chronic Obstructive Pulmonary Disease.

    PubMed

    Santibáñez, Miguel; Garrastazu, Roberto; Ruiz-Nuñez, Mario; Helguera, Jose Manuel; Arenal, Sandra; Bonnardeux, Cristina; León, Carlos; García-Rivero, Juan Luis

    2016-01-01

    Exacerbations of chronic obstructive pulmonary disease (COPD) carry significant consequences for patients and are responsible for considerable health-care costs-particularly if hospitalization is required. Despite the importance of hospitalized exacerbations, relatively little is known about their determinants. This study aimed to analyze predictors of hospitalized exacerbations and mortality in COPD patients. This was a retrospective population-based cohort study. We selected 900 patients with confirmed COPD aged ≥35 years by simple random sampling among all COPD patients in Cantabria (northern Spain) on December 31, 2011. We defined moderate exacerbations as events that led a care provider to prescribe antibiotics or corticosteroids and severe exacerbations as exacerbations requiring hospital admission. We observed exacerbation frequency over the previous year (2011) and following year (2012). We categorized patients according to COPD severity based on forced expiratory volume in 1 second (Global Initiative for Chronic Obstructive Lung Disease [GOLD] grades 1-4). We estimated the odds ratios (ORs) by logistic regression, adjusting for age, sex, smoking status, COPD severity, and frequent exacerbator phenotype the previous year. Of the patients, 16.4% had ≥1 severe exacerbations, varying from 9.3% in mild GOLD grade 1 to 44% in very severe COPD patients. A history of at least two prior severe exacerbations was positively associated with new severe exacerbations (adjusted OR, 6.73; 95% confidence interval [CI], 3.53-12.83) and mortality (adjusted OR, 7.63; 95%CI, 3.41-17.05). Older age and several comorbidities, such as heart failure and diabetes, were similarly associated. Hospitalized exacerbations occurred with all grades of airflow limitation. A history of severe exacerbations was associated with new hospitalized exacerbations and mortality.

  8. The impact of obstructive sleep apnea syndrome on renin and aldosterone.

    PubMed

    Lykouras, D; Theodoropoulos, K; Sampsonas, F; Lagiou, O; Lykouras, M; Spiropoulou, A; Flordellis, C; Alexandrides, T; Karkoulias, K; Spiropoulos, K

    2015-11-01

    Obstructive Sleep Apnoea Syndrome (OSAS) is a respiratory disorder characterized by recurrent airflow obstruction caused by total or partial collapse of the upper airway. OSAS is an established independent factor of cardiovascular risk together with other risk factors such as smoking and increased lipids. The aim of our study was to measure serum levels of aldosterone and renin in OSAS patients that did not suffer from arterial hypertension and compare them to matched healthy subjects in order to reveal the impact of chronic intermittent hypoxia on the renin-angiotensin-aldosterone system. The patients that enrolled in this study were 19 OSAS patients who had undergone overnight polysomnography and had an Apnoea Hypopnoea Index (AHI) greater than 10 events/hour. They were compared to 20 healthy non-OSAS closely matched controls. Serum aldosterone and direct renin concentration were measured by radioimmunoassay. Aldosterone concentration follows a diurnal variation; therefore, all blood samples were obtained at the same time (6 AM). There were no significant differences in serum aldosterone levels between the two studied groups of OSAS patients and the healthy subjects group (140.6 pg/ml ± 25.2 vs. 133.2 pg/ml ± 18.5 with p = 0.223). Similar were the results for the renin levels (25.0 ± 6.9 vs. 24.9 ± 4.4 with p = 0.360). Our study suggests that patients with OSAS, but without existing hypertension have aldosterone and renin levels similar to healthy subjects. According to our findings a direct connection between OSAS and the development of arterial hypertension may not be established via sympathetic system activation.

  9. Comparison of pitot traverses taken at varying distances downstream of obstructions.

    PubMed

    Guffey, S E; Booth, D W

    1999-01-01

    This study determined the deviations between pitot traverses taken under "ideal" conditions--at least seven duct diameter's lengths (i.e., distance = 7D) from obstructions, elbows, junction fittings, and other disturbances to flows--with those taken downstream from commonplace disturbances. Two perpendicular 10-point, log-linear velocity pressure traverses were taken at various distances downstream of tested upstream conditions. Upstream conditions included a plain duct opening, a junction fitting, a single 90 degrees elbow, and two elbows rotated 90 degrees from each other into two orthogonal planes. Airflows determined from those values were compared with the values measured more than 40D downstream of the same obstructions under ideal conditions. The ideal measurements were taken on three traverse diameters in the same plane separated by 120 degrees in honed drawn-over-mandrel tubing. In all cases the pitot tubes were held in place by devices that effectively eliminated alignment errors and insertion depth errors. Duct velocities ranged from 1500 to 4500 ft/min. Results were surprisingly good if one employed two perpendicular traverses. When the averages of two perpendicular traverses was taken, deviations from ideal value were 6% or less even for traverses taken as close as 2D distance from the upstream disturbances. At 3D distance, deviations seldom exceeded 5%. With single diameter traverses, errors seldom exceeded 5% at 6D or more downstream from the disturbance. Interestingly, percentage deviations were about the same at high and low velocities. This study demonstrated that two perpendicular pitot traverses can be taken as close as 3D from these disturbances with acceptable (< or = 5%) deviations from measurements taken under ideal conditions.

  10. The importance of side difference in nasal obstruction and rhinomanometry: a retrospective correlation of symptoms and rhinomanometry in 1000 patients.

    PubMed

    Thulesius, H L; Cervin, A; Jessen, M

    2012-02-01

    The correlation between subjective and objective outcomes of nasal obstruction is still a matter of controversy. The aim of this study was to determine the minimal level of side difference in nasal airway resistance (NAR measured by Broms'v(2)) between the two nasal cavities, which could be discerned subjectively by the patient on a visual analogue scale (VAS). Nasal airway resistance was calculated from rhinomanometric measurements of nasal airflow and transnasal pressure after decongestion of the nasal mucosa. A retrospective study. ENT department, Vaxjo Central Hospital, Sweden. We studied 1000 active anterior rhinomanometries from patients with nasal obstructions. We compared the side difference of nasal airway resistance with the side difference of VAS estimated immediately prior to the rhinomanometry. Each measurement was performed after nasal decongestion. When the difference in nasal airway resistance between the two nasal cavities was larger than 20° (Broms'v(2)) or R(2) > 0.36 Pa/cm(3) /s, we found a significant correlation between side differences of the objective measurement and the subjective assessment (VAS). With a nasal airway resistance side difference over 20°, an additional 20° difference corresponded to a 0.9 centimetre average VAS change. The more obstructed side of the nose could be determined by VAS in 823 (82.3%) of 1000 patients. Yet, 177 (17.7%) patients had a paradoxical sensation of nasal obstruction with the low resistance side of the nose experienced as the most congested side. A significant correlation between the side differences of nasal airway resistance and VAS can serve as a supplement to rhinoscopy in decisions about nasal surgery. This study also showed that in 17.7% of patients, there was a negative correlation between subjective and objective evaluations of nasal airway resistance. But in this group, the nasal airway resistance side difference was mostly under 20°. © 2011 Blackwell Publishing Ltd.

  11. Subglottal pressure, tracheal airflow, and intrinsic laryngeal muscle activity during rat ultrasound vocalization

    PubMed Central

    2011-01-01

    Vocal production requires complex planning and coordination of respiratory, laryngeal, and vocal tract movements, which are incompletely understood in most mammals. Rats produce a variety of whistles in the ultrasonic range that are of communicative relevance and of importance as a model system, but the sources of acoustic variability were mostly unknown. The goal was to identify sources of fundamental frequency variability. Subglottal pressure, tracheal airflow, and electromyographic (EMG) data from two intrinsic laryngeal muscles were measured during 22-kHz and 50-kHz call production in awake, spontaneously behaving adult male rats. During ultrasound vocalization, subglottal pressure ranged between 0.8 and 1.9 kPa. Pressure differences between call types were not significant. The relation between fundamental frequency and subglottal pressure within call types was inconsistent. Experimental manipulations of subglottal pressure had only small effects on fundamental frequency. Tracheal airflow patterns were also inconsistently associated with frequency. Pressure and flow seem to play a small role in regulation of fundamental frequency. Muscle activity, however, is precisely regulated and very sensitive to alterations, presumably because of effects on resonance properties in the vocal tract. EMG activity of cricothyroid and thyroarytenoid muscle was tonic in calls with slow or no fundamental frequency modulations, like 22-kHz and flat 50-kHz calls. Both muscles showed brief high-amplitude, alternating bursts at rates up to 150 Hz during production of frequency-modulated 50-kHz calls. A differentiated and fine regulation of intrinsic laryngeal muscles is critical for normal ultrasound vocalization. Many features of the laryngeal muscle activation pattern during ultrasound vocalization in rats are shared with other mammals. PMID:21832032

  12. Design of multi-modal obstruction to control tonal fan noise using modulation principles

    NASA Astrophysics Data System (ADS)

    Gérard, Anthony; Moreau, Stéphane; Berry, Alain; Masson, Patrice

    2015-11-01

    The approach presented in this paper uses a combination of obstructions in the upstream flow of subsonic axial fans with B blades to destructively interfere with the primary tonal noise at the blade passage frequency. The first step of the proposed experimental method consists in identifying the independent radiation of B - 1 and B lobed obstructions at the control microphones. During this identification step, rotating obstructions allow for the frequencies of primary and secondary tonal noise to be slightly shifted in the spectrum due to modulation principles. The magnitude of the secondary tonal noise generated by each obstruction can be adjusted by varying the size of the lobes of the obstruction, and the phase of the secondary tonal noise is related to the angular position of the obstruction. The control obstructions are then optimized by combining the B - 1 and B lobed obstructions to significantly reduce the acoustic power at blade passage frequency.

  13. Reconstruction of sound source signal by analytical passive TR in the environment with airflow

    NASA Astrophysics Data System (ADS)

    Wei, Long; Li, Min; Yang, Debin; Niu, Feng; Zeng, Wu

    2017-03-01

    In the acoustic design of air vehicles, the time-domain signals of noise sources on the surface of air vehicles can serve as data support to reveal the noise source generation mechanism, analyze acoustic fatigue, and take measures for noise insulation and reduction. To rapidly reconstruct the time-domain sound source signals in an environment with flow, a method combining the analytical passive time reversal mirror (AP-TR) with a shear flow correction is proposed. In this method, the negative influence of flow on sound wave propagation is suppressed by the shear flow correction, obtaining the corrected acoustic propagation time delay and path. Those corrected time delay and path together with the microphone array signals are then submitted to the AP-TR, reconstructing more accurate sound source signals in the environment with airflow. As an analytical method, AP-TR offers a supplementary way in 3D space to reconstruct the signal of sound source in the environment with airflow instead of the numerical TR. Experiments on the reconstruction of the sound source signals of a pair of loud speakers are conducted in an anechoic wind tunnel with subsonic airflow to validate the effectiveness and priorities of the proposed method. Moreover the comparison by theorem and experiment result between the AP-TR and the time-domain beamforming in reconstructing the sound source signal is also discussed.

  14. Chronic obstructive pulmonary disease and malnutrition in developing countries.

    PubMed

    Sehgal, Inderpaul S; Dhooria, Sahajal; Agarwal, Ritesh

    2017-03-01

    Chronic obstructive pulmonary disease (COPD) is a chronic inflammatory lung disorder characterized by progressive, poorly reversible airflow limitation. In addition to its pulmonary manifestations, COPD is also associated with several systemic expressions including anemia, osteoporosis, coronary artery disease, and malnutrition. In COPD, malnutrition is a consequence of reduced nutritional intake and muscle loss, further compounded by systemic inflammation. In the developing world, malnutrition is a significant problem by itself, even without any systemic illness. It is likely that the occurrence and consequence of malnutrition in COPD may be even more profound in developing countries. In this review, we discuss the relationship between malnutrition and COPD and their overall impact in the developing world. COPD is highly prevalent in developing countries with an estimated 15-43 million patients suffering from COPD. The pooled prevalence of malnutrition in COPD was found to be 47.6% [95% confidence interval (CI), 23.5-71.5%] with the prevalence being higher in acute exacerbations of COPD compared to stable COPD. There is a need for generating good quality evidence from the developing world regarding the prevalence of malnutrition in COPD, the role of nutritional supplementation and its impact on exercise capacity, and overall health-related quality of life in patients with COPD.

  15. Neck circumference, metabolic syndrome and obstructive sleep apnea syndrome; Evaluation of possible linkage

    PubMed Central

    Ahbab, Süleyman; Ataoğlu, Hayriye Esra; Tuna, Mazhar; Karasulu, Levent; Çetin, Faik; Temiz, Levent Ümit; Yenigün, Mustafa

    2013-01-01

    Background This study was performed to evaluate neck circumference (NC) and metabolic syndrome (MS) parameters in severe and non-severe (mild-moderate) obstructive sleep apnea syndrome (OSAS) patients according to apnea-hypopnea index (AHI). Material/Method We enrolled 44 patients diagnosed with OSAS based on overnight polysomnography. The diagnosis of OSAS was based on AHI. Apnea is a pause of airflow for more than 10 seconds. and hypopnea is a decrease of airflow for more than 10 seconds and oxygen desaturation of 4% or greater. AHI score. per hour; below 5 normal. 5–29 mild-moderate. 30 and above were grouped as severe OSAS. Height. weight. neck circumference (NC). waist circumference (WC) and body mass index (BMI) of the patients were measured. MS was diagnosed by the Adult Treatment Panel (ATP) III criteria (≥3 of the following abnormalities): 1) WC ≥94 cm for males, ≥80 cm for females; 2) arterial blood pressure ≥130/85 mmHg; 3) fasting blood glucose ≥100 mg/dl; 4) high density lipoprotein (HDL) cholesterol <40 mg/dl in man, <50 mg/dl in women; 5) triglycerides ≥150 mg/dl. Results Mean BMI and NC were higher in severe OSAS patients compared to non-severe patients (p=0.021. p<0.001). According to ATP III criteria. 64% of severe and 61.1% of non-severe OSAS patients were MS (p=0.847). A logistic regression model displayed an association with NC as a risk factor for severe OSAS (p=0.01). but not with MS. Conclusions In this study. NC in severe OSAS patients was significantly higher than in non-severe OSAS patients. The prevalence of metabolic syndrome was not correlated with OSAS severity. NC is an independent risk factor for severe OSAS. PMID:23403781

  16. Test-Retest Reliability of Respiratory Resistance Measured with the Airflow Perturbation Device

    ERIC Educational Resources Information Center

    Gallena, Sally K.; Solomon, Nancy Pearl; Johnson, Arthur T.; Vossoughi, Jafar; Tian, Wei

    2014-01-01

    Purpose: In this study, the authors aimed to determine reliability of the airflow perturbation device (APD) to measure respiratory resistance within and across sessions during resting tidal (RTB) and postexercise breathing in healthy athletes, and during RTB across trials within a session in athletes with paradoxical vocal fold motion (PVFM)…

  17. Laminar-airflow equipment certification: what the pharmacist needs to know.

    PubMed

    Bryan, D; Marback, R C

    1984-07-01

    The basic information pharmacy practitioners need to determine the suitability and applicability of laminar-airflow equipment test standards and procedures is presented. The operative guideline for any laminar-flow clean bench (LFCB) certification is the cleanroom and work station requirements for controlled environments as defined by the federal government under Federal Standard 209b (FS 209b). FS 209b outlines the tests, test procedures, and acceptable performance ranges for all LFCB equipment. National Sanitation Foundation Standard Number 49 (NSF 49) is used in the certification of biological-safety cabinets (BSCs). NSF 49 covers those aspects of safety, maintenance, performance, and testing that are unique BSCs. To monitor certification properly, practitioners should be familiar with these standards and the air-velocity profile, high-efficiency particulate air filter performance, noise output, light, and electrical test procedures. A review of the requisite knowledge, experience, and reputation of certifying agents is presented, along with an outline of all the necessary procedures, equipment, and documentation to be used in the process. A thorough test report should be issued upon unit certification. As pharmacy practitioners are responsible for all other aspects of quality assurance, they should also be capable of auditing these certifications to ensure the aseptic quality of products compounded in the laminar-airflow environment.

  18. Clinical Outcomes of Self-Expandable Metal Stents for Malignant Rectal Obstruction.

    PubMed

    Lee, Hyun Jung; Hong, Sung Pil; Cheon, Jae Hee; Kim, Tae Il; Kim, Won Ho; Park, Soo Jung

    2018-01-01

    Self-expandable metal stents are widely used to treat malignant colorectal obstruction. However, data on clinical outcomes of stent placement for rectal obstruction specifically are lacking. We aimed to investigate the clinical outcomes of self-expandable metal stents in malignant rectal obstruction in comparison with those in left colonic obstruction and to identify factors associated with clinical failure and complication. This was a retrospective study. The study was conducted at a tertiary care center. Between January 2005 and December 2013, medical charts of patients who underwent stent placement for malignant rectal or left colonic obstruction were reviewed retrospectively. Study intervention included self-expandable metal stent placement. Technical success, clinical success, and complications were measured. Technical success rates for the 2 study groups (rectum vs left colon, 93.5% vs 93.1%; p = 0.86) did not differ significantly; however, the clinical success rate was lower in patients with rectal obstruction (85.4% vs 92.1%; p = 0.02). In addition, the complication rate was higher in patients with rectal obstruction (37.4% vs 25.1%; p = 0.01). Patients with rectal obstruction showed higher rates of obstruction because of extracolonic malignancy (33.8% vs 15.8%; p < 0.001) and stent use for palliation (78.6% vs 56.3%; p < 0.001). Multivariate analysis indicated obstruction attributed to extracolonic malignancy and covered stent usage to be independent risk factors for clinical failure. Factors predictive of complications in the palliative group were total obstruction, obstruction because of extracolonic malignancy, and covered stent usage. This was a retrospective, single-center study. The efficacy and safety of stent placement for malignant rectal obstruction were comparable with those for left colonic obstruction. However, obstruction attributed to extracolonic malignancy, use of covered stents, and total obstruction negatively impacted clinical outcomes

  19. Porous silver nanosheets: a novel sensing material for nanoscale and microscale airflow sensors

    NASA Astrophysics Data System (ADS)

    Marzbanrad, Ehsan; Zhao, Boxin; Zhou, Norman Y.

    2015-11-01

    Fabrication of nanoscale and microscale machines and devices is one of the goals of nanotechnology. For this purpose, different materials, methods, and devices should be developed. Among them, various types of miniaturized sensors are required to build the nanoscale and microscale systems. In this research, we introduce a new nanoscale sensing material, silver nanosheets, for applications such as nanoscale and microscale gas flow sensors. The silver nanosheets were synthesized through the reduction of silver ions by ascorbic acid in the presence of poly(methacrylic acid) as a capping agent, followed by the growth of silver in the shape of hexagonal and triangular nanoplates, and self-assembly and nanojoining of these structural blocks. At the end of this process, the synthesized nanosheets were floated on the solution. Then, their electrical and thermal stability was demonstrated at 120 °C, and their atmospheric corrosion resistance was clarified at the same temperature range by thermogravimetric analysis. We employed the silver nanosheets in fabricating airflow sensors by scooping out the nanosheets by means of a sensor substrate, drying them at room temperature, and then annealing them at 300 °C for one hour. The fabricated sensors were tested for their ability to measure airflow in the range of 1 to 5 ml min-1, which resulted in a linear response to the airflow with a response and recovery time around 2 s. Moreover, continuous dynamic testing demonstrated that the response of the sensors was stable and hence the sensors can be used for a long time without detectable drift in their response.

  20. Sleep Architecture Linked to Airway Obstruction and Intracranial Hypertension in Children with Syndromic Craniosynostosis.

    PubMed

    Spruijt, Bart; Mathijssen, Irene M J; Bredero-Boelhouwer, Hansje H; Cherian, Perumpillichira J; Corel, Linda J A; van Veelen, Marie-Lise; Hayward, Richard D; Tasker, Robert C; Joosten, Koen F M

    2016-12-01

    Children with syndromic craniosynostosis often have obstructive sleep apnea and intracranial hypertension. The authors aimed to evaluate (1) sleep architecture, and determine whether this is influenced by the presence of obstructive sleep apnea and/or intracranial hypertension; and (2) the effect of treatment on sleep architecture. This study included patients with syndromic craniosynostosis treated at a national referral center, undergoing screening for obstructive sleep apnea and intracranial hypertension. Obstructive sleep apnea was identified by polysomnography, and categorized into no, mild, moderate, or severe. Intracranial hypertension was identified by the presence of papilledema on funduscopy, supplemented by optical coherence tomography and/or intracranial pressure monitoring. Regarding sleep architecture, sleep was divided into rapid eye movement or non-rapid eye movement sleep; respiratory effort-related arousals and sleep efficiency were scored. The authors included 39 patients (median age, 5.9 years): 19 with neither obstructive sleep apnea nor intracranial hypertension, 11 with obstructive sleep apnea (four moderate/severe), six with intracranial hypertension, and three with obstructive sleep apnea and intracranial hypertension. Patients with syndromic craniosynostosis, independent of the presence of mild obstructive sleep apnea and/or intracranial hypertension, have normal sleep architecture compared with age-matched controls. Patients with moderate/severe obstructive sleep apnea have a higher respiratory effort-related arousal index (p < 0.01), lower sleep efficiency (p = 0.01), and less rapid eye movement sleep (p = 0.04). An improvement in sleep architecture was observed following monobloc surgery (n = 5; rapid eye movement sleep, 5.3 percent; p = 0.04). Children with syndromic craniosynostosis have in principle normal sleep architecture. However, moderate/severe obstructive sleep apnea does lead to disturbed sleep architecture, which fits within

  1. The Relationship Between Pulmonary Emphysema and Kidney Function in Smokers

    PubMed Central

    Chandra, Divay; Stamm, Jason A.; Palevsky, Paul M.; Leader, Joseph K.; Fuhrman, Carl R.; Zhang, Yingze; Bon, Jessica; Duncan, Steven R.; Branch, Robert A.; Weissfeld, Joel; Gur, David; Gladwin, Mark T.

    2012-01-01

    Background: It has been reported that the prevalence of kidney dysfunction may be increased in patients exposed to tobacco with airflow obstruction. We hypothesized that kidney dysfunction would associate with emphysema rather than with airflow obstruction measured by the FEV1. Methods: Five hundred eight current and former smokers completed a chest CT scan, pulmonary function tests, medical questionnaires, and measurement of serum creatinine. Glomerular filtration rates (eGFRs) were estimated using the method of the Chronic Kidney Disease Epidemiology Collaboration. Quantitative determinants of emphysema and airway dimension were measured from multidetector chest CT scans. Results: The mean age was 66 ± 7 years, and mean eGFR was 101 ± 22 mL/min/1.73 m2. Univariate and multivariate analysis showed a significant association between radiographically measured emphysema and eGFR: Participants with 10% more emphysema had an eGFR that was lower by 4.4 mL/min/1.73 m2 (P = .01), independent of airflow obstruction (FEV1), age, sex, race, height, BMI, diabetes mellitus, hypertension, coronary artery disease, patient-reported dyspnea, pack-years of smoking, and current smoking. There was no association between eGFR and either FEV1 or quantitative CT scan measures of airway dimension. Conclusions: More severe emphysema, rather than airflow obstruction, is associated with kidney dysfunction in tobacco smokers, independent of common risk factors for kidney disease. This finding adds to recent observations of associations between emphysema and comorbidities of COPD, including osteoporosis and lung cancer, which are independent of the traditional measure of reduced FEV1. The mechanisms and clinical implications of kidney dysfunction in patients with emphysema need further investigation. PMID:22459775

  2. The relationship between different diet quality indices and severity of airflow obstruction among COPD patients

    PubMed Central

    Yazdanpanah, Leila; Paknahad, Zamzam; Moosavi, Ali Javad; Maracy, Mohammad Reza; Zaker, Mohammad Masoud

    2016-01-01

    Background: Chronic obstructive pulmonary disease (COPD) is a major public health problem worldwide. Smoking is the number one cause of COPD; however, genetic, environmental and dietary factors contribute to the etiology of this disease. In this study, we assessed the association between three diet quality indices -the Healthy Eating Index-2005 (HEI-2005), the Healthy Eating Index-2010 (HEI-2010), and Mediterranean Diet Score (MED)- and the severity of disease in COPD patients. Methods: This cross-sectional study was performed at Rasul-e-Akram Hospital in Tehran on 121 COPD patients with the mean age of (SD) of 66.1(10.9) years. A pulmonary specialist diagnosed all participants based on a spirometry test. They were categorized into four groups (1, 2, 3, 4 stages of disease). Three diet quality indices, spirometry test and determination of disease severity were performed for all the participants. ANCOVA and Kruskal-Wallis test were used to assess the relationship between dietary quality indices and severity of the disease. The relationship between HEI-2010, HEI-2005, MED score, their components and lung function was assessed using a multiple linear regression analysis. All analyses were done using SPSS 18. Results: Reduction of the Healthy Eating Index-2010 and MED score were observed along with the increase in disease severity, but they were not significant. The relationship between the three diet quality indices and lung function showed a significant association between MED score and Forced expiratory volume in one second (FEV1), The Forced Vital Capacity (FVC) (β=2.9, 95% CI (1.1, 4.8), p=0.002), (β=2.8, 95% CI (0.9, 4.8), p=0.007), respectively. Conclusion: Mediterranean dietary pattern and obtaining a better score on HEI-2010 diet were associated with a better lung function test. PMID:27493924

  3. Airflow reduction during cold weather operation of residential heat recovery ventilators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGugan, C.A.; Edwards, P.F.; Riley, M.A.

    1987-06-01

    Laboratory measurements of the performance of residential heat recovery ventilators have been carried out for the R-2000 Energy Efficient Home Program. This work was based on a preliminary test procedure developed by the Canadian Standards Association, part of which calls for testing the HRV under cold weather conditions. An environmental chamber was used to simulate outdoor conditions. Initial tests were carried out with an outdoor temperature of -20/sup 0/C; subsequent tests were carried out at a temperature of -25/sup 0/C. During the tests, airflows, temperatures, and relative humidities of airstreams entering and leaving the HRV, along with electric power inputs,more » were monitored. Frost buildup in the heat exchangers and defrost mechanisms, such as fan shutoff or recirculation, led to reductions in airflows. The magnitude of the reductions is dependent on the design of the heat exchanger and the defrost mechanism used. This paper presents the results of tests performed on a number of HRVs commercially available in Canada at the time of the testing. The flow reductions for the various defrost mechanisms are discussed.« less

  4. Pneumothorax risk factors in smokers with and without chronic obstructive pulmonary disease.

    PubMed

    Hobbs, Brian D; Foreman, Marilyn G; Bowler, Russell; Jacobson, Francine; Make, Barry J; Castaldi, Peter J; San José Estépar, Raúl; Silverman, Edwin K; Hersh, Craig P

    2014-11-01

    The demographic, physiological, and computed tomography (CT) features associated with pneumothorax in smokers with and without chronic obstructive pulmonary disease (COPD) are not clearly defined. We evaluated the hypothesis that pneumothorax in smokers is associated with male sex, tall and thin stature, airflow obstruction, and increased total and subpleural emphysema. The study included smokers with and without COPD from the COPDGene Study, with quantitative chest CT analysis. Pleural-based emphysema was assessed on the basis of local histogram measures of emphysema. Pneumothorax history was defined by subject self-report. Pneumothorax was reported in 286 (3.2%) of 9,062 participants. In all participants, risk of prior pneumothorax was significantly higher in men (odds ratio [OR], 1.55; 95% confidence interval [CI], 1.08-2.22) and non-Hispanic white subjects (OR, 1.90; 95% CI, 1.34-2.69). Risk of prior pneumothorax was associated with increased percent CT emphysema in all participants and participants with COPD (OR, 1.04 for each 1% increase in emphysema; 95% CI, 1.03-1.06). Increased pleural-based emphysema was independently associated with risk of past pneumothorax in all participants (OR, 1.05 for each 1% increase; 95% CI, 1.01-1.10). In smokers with normal spirometry, risk of past pneumothorax was associated with non-Hispanic white race and lifetime smoking intensity (OR, 1.20 for every 10 pack-years; 95% CI, 1.09-1.33). Among smokers, pneumothorax is associated with male sex, non-Hispanic white race, and increased percentage of total and subpleural CT emphysema. Pneumothorax was not independently associated with height or lung function, even in participants with COPD. Clinical trial registered with www.clinicaltrials.gov (NCT00608764).

  5. Sex differences in chronic obstructive pulmonary disease evaluated using optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Kirby, Miranda; Zhang, Wei; Laratta, Peter K.; Sin, Don D.; Lam, Stephen; Coxson, Harvey O.

    2014-03-01

    Although there are more women than men dying of chronic obstructive pulmonary disease (COPD) in the United States and elsewhere, we still do not have a clear understanding of the differences in the pathophysiology of airflow obstruction between the sexes. Optical coherence tomography (OCT) is an emerging imaging technology that has the capability of imaging small bronchioles with resolution approaching histology. Therefore, our objective was to compare OCT-derived airway wall measurements between males and females matched for lung size and in anatomically matched small airways. Subjects 50-80 yrs were enrolled in the British Columbia Lung Health Study and underwent OCT and spirometry. OCT was performed using a 1.5mm diameter probe/sheath in anatomically matched airways for males and females; the right lower lobe (RB8 or RB9) or left lower lobe (LB8 or LB9) during end-expiration. OCT airway wall area (Aaw) was obtained by manual segmentation. For males and females there was no significant difference in OCT Aaw (p=0.12). Spearman correlation coefficients indicated that the forced expiratory volume in 1 second (FEV1) and Aaw were significantly correlated for males (r=-0.78, p=0.004) but not for females (r=-0.20, p=0.49) matched for lung size. These novel OCT findings demonstrate that while there were no overall sex differences in airway wall thickness, the relationship between lung function and airway wall thickness was correlated only in men. Therefore, factors other than airway remodeling may be driving COPD pathogenesis in women and OCT may provide important information for investigating airway remodeling and its relationship with COPD progression.

  6. Redefining Cut-Points for High Symptom Burden of the Global Initiative for Chronic Obstructive Lung Disease Classification in 18,577 Patients With Chronic Obstructive Pulmonary Disease.

    PubMed

    Smid, Dionne E; Franssen, Frits M E; Gonik, Maria; Miravitlles, Marc; Casanova, Ciro; Cosio, Borja G; de Lucas-Ramos, Pilar; Marin, Jose M; Martinez, Cristina; Mir, Isabel; Soriano, Joan B; de Torres, Juan P; Agusti, Alvar; Atalay, Nart B; Billington, Julia; Boutou, Afroditi K; Brighenti-Zogg, Stefanie; Chaplin, Emma; Coster, Samantha; Dodd, James W; Dürr, Selina; Fernandez-Villar, Alberto; Groenen, Miriam T J; Guimarães, Miguel; Hejduk, Karel; Higgins, Victoria; Hopkinson, Nicholas S; Horita, Nobuyuki; Houben-Wilke, Sarah; Janssen, Daisy J A; Jehn, Melissa; Joerres, Rudolf; Karch, Annika; Kelly, Julia L; Kim, Yu-Il; Kimura, Hiroshi; Koblizek, Vladimir; Kocks, Janwillem H; Kon, Samantha S C; Kwon, Namhee; Ladeira, Inês; Lee, Sang-Do; Leuppi, Joerg D; Locantore, Nicholas; Lopez-Campos, José L; D-C Man, William; Maricic, Lana; Mendoza, Laura; Miedinger, David; Mihaltan, Florin; Minami, Seigo; van der Molen, Thys; Murrells, Trevor J; Nakken, Nienke; Nishijima, Yu; Norman, Ian J; Novotna, Barbora; O'Donnell, Denis E; Ogata, Yoshitaka; Pereira, Eanes D; Piercy, James; Price, David; Pothirat, Chaicharn; Raghavan, Natya; Ringbaek, Thomas; Sajkov, Dimitar; Sigari, Naseh; Singh, Sally; Small, Mark; da Silva, Guilherme F; Tanner, Rebecca J; Tsiligianni, Ioanna G; Tulek, Baykal; Tzanakis, Nikolaos; Vanfleteren, Lowie E G W; Watz, Henrik; Webb, Katherine A; Wouters, Emiel F M; Xie, Guogang G; Yoshikawa, Masanori; Spruit, Martijn A

    2017-12-01

    Patients with chronic obstructive pulmonary disease (COPD) can be classified into groups A/C or B/D based on symptom intensity. Different threshold values for symptom questionnaires can result in misclassification and, in turn, different treatment recommendations. The primary aim was to find the best fitting cut-points for Global initiative for chronic Obstructive Lung Disease (GOLD) symptom measures, with an modified Medical Research Council dyspnea grade of 2 or higher as point of reference. After a computerized search, data from 41 cohorts and whose authors agreed to provide data were pooled. COPD studies were eligible for analyses if they included, at least age, sex, postbronchodilator spirometry, modified Medical Research Council, and COPD Assessment Test (CAT) total scores. Receiver operating characteristic curves and the Youden index were used to determine the best calibration threshold for CAT, COPD Clinical Questionnaire, and St. Georges Respiratory Questionnaire total scores. Following, GOLD A/B/C/D frequencies were calculated based on current cut-points and the newly derived cut-points. A total of 18,577 patients with COPD [72.0% male; mean age: 66.3 years (standard deviation 9.6)] were analyzed. Most patients had a moderate or severe degree of airflow limitation (GOLD spirometric grade 1, 10.9%; grade 2, 46.6%; grade 3, 32.4%; and grade 4, 10.3%). The best calibration threshold for CAT total score was 18 points, for COPD Clinical Questionnaire total score 1.9 points, and for St. Georges Respiratory Questionnaire total score 46.0 points. The application of these new cut-points would reclassify about one-third of the patients with COPD and, thus, would impact on individual disease management. Further validation in prospective studies of these new values are needed. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  7. The influence of wind speed on airflow and fine particle transport within different building layouts of an industrial city.

    PubMed

    Mei, Dan; Wen, Meng; Xu, Xuemei; Zhu, Yuzheng; Xing, Futang

    2018-04-20

    In atmospheric environment, the layout difference of urban buildings has a powerful influence on accelerating or inhibiting the dispersion of particle matters (PM). In industrial cities, buildings of variable heights can obstruct the diffusion of PM from industrial stacks. In this study, PM dispersed within building groups was simulated by Reynolds-averaged Navier-Stokes equations coupled Lagrangian approach. Four typical street building arrangements were used: (a) a low-rise building block with Height/base H/b = 1 (b = 20 m); (b) step-up building layout (H/b = 1, 2, 3, 4); (c) step-down building layout (H/b = 4, 3, 2, 1); (d) high-rise building block (H/b = 5). Profiles of stream functions and turbulence intensity were used to examine the effect of various building layouts on atmospheric airflow. Here, concepts of particle suspension fraction and concentration distribution were used to evaluate the effect of wind speed on fine particle transport. These parameters showed that step-up building layouts accelerated top airflow and diffused more particles into street canyons, likely having adverse effects on resident health. In renewal old industry areas, the step-down building arrangement which can hinder PM dispersion from high-level stacks should be constructed preferentially. High turbulent intensity results in formation of a strong vortex that hinders particles into the street canyons. It is found that an increase in wind speed enhanced particle transport and reduced local particle concentrations, however, it did not affect the relative location of high particle concentration zones, which are related to building height and layout. This study has demonstrated the height variation and layout of urban architecture affect the local concentration distribution of particulate matter (PM) in the atmosphere and for the first time that wind velocity has particular effects on PM transport in various building groups. The findings may have general implications in optimization

  8. Numerical modeling of turbulent and laminar airflow and odorant transport during sniffing in the human and rat nose.

    PubMed

    Zhao, Kai; Dalton, Pamela; Yang, Geoffery C; Scherer, Peter W

    2006-02-01

    Human sniffing behavior usually involves bouts of short, high flow rate inhalation (>300 ml/s through each nostril) with mostly turbulent airflow. This has often been characterized as a factor enabling higher amounts of odorant to deposit onto olfactory mucosa than for laminar airflow and thereby aid in olfactory detection. Using computational fluid dynamics human nasal cavity models, however, we found essentially no difference in predicted olfactory odorant flux (g/cm2 s) for turbulent versus laminar flow for total nasal flow rates between 300 and 1000 ml/s and for odorants of quite different mucosal solubility. This lack of difference was shown to be due to the much higher resistance to lateral odorant mass transport in the mucosal nasal airway wall than in the air phase. The simulation also revealed that the increase in airflow rate during sniffing can increase odorant uptake flux to the nasal/olfactory mucosa but lower the cumulative total uptake in the olfactory region when the inspired air/odorant volume was held fixed, which is consistent with the observation that sniff duration may be more important than sniff strength for optimizing olfactory detection. In contrast, in rats, sniffing involves high-frequency bouts of both inhalation and exhalation with laminar airflow. In rat nose odorant uptake simulations, it was observed that odorant deposition was highly dependent on solubility and correlated with the locations of different types of receptors.

  9. Acute GI obstruction.

    PubMed

    Hucl, Tomas

    2013-10-01

    Acute gastrointestinal obstruction occurs when the normal flow of intestinal contents is interrupted. The blockage can occur at any level throughout the gastrointestinal tract. The clinical symptoms depend on the level and extent of obstruction. Various benign and malignant processes can produce acute gastrointestinal obstruction, which often represents a medical emergency because of the potential for bowel ischemia leading to perforation and peritonitis. Early recognition and appropriate treatment are thus essential. The typical clinical symptoms associated with obstruction include nausea, vomiting, dysphagia, abdominal pain and failure to pass bowel movements. Abdominal distention, tympany due to an air-filled stomach and high-pitched bowel sounds suggest the diagnosis. The diagnostic process involves imaging including radiography, ultrasonography, contrast fluoroscopy and computer tomography in less certain cases. In patients with uncomplicated obstruction, management is conservative, including fluid resuscitation, electrolyte replacement, intestinal decompression and bowel rest. In many cases, endoscopy may aid in both the diagnostic process and in therapy. Endoscopy can be used for bowel decompression, dilation of strictures or placement of self-expandable metal stents to restore the luminal flow either as a final treatment or to allow for a delay until elective surgical therapy. When gastrointestinal obstruction results in ischemia, perforation or peritonitis, emergency surgery is required. Copyright © 2013. Published by Elsevier Ltd.

  10. Clinical impact of the lower limit of normal of FEV1/FVC on detecting chronic obstructive pulmonary disease: A follow-up study based on cross-sectional data.

    PubMed

    Liu, Sha; Zhou, Yumin; Liu, Shiliang; Zou, Weifeng; Li, Xiaochen; Li, Chenglong; Deng, Zhishan; Zheng, Jinzhen; Li, Bing; Ran, Pixin

    2018-06-01

    Criteria of obstruction that establish a diagnosis of COPD have been debated in recent years. We carried out a follow-up study to assess the impact of the new LLN reference equation for Chinese on detecting COPD compared with the traditional 0.7fixed criteria. We examined the prevalence and characteristics of airflow limitation for a non-child population using post-bronchodilator airflow with both age-dependent predicted lower limit of the normal value and fixed-ratio spirometric criterion. Questionnaires and spirometry were completed for all eligible subjects during the baseline examination. Participants with inconsistent diagnosis according to the two criteria, normal participants (controls) and COPD patients in stages I or II, were invited to take a cardiopulmonary exercise testing (CPET) examination and follow up for 2-4 years. A total of 5448 (mean age 50.51 ± 13.2 yr) study subjects with acceptable spirometry and complete questionnaire data were included in our final analyses. COPD detection based on LLN was consistent with the GOLD 0.7 fixed-ratio in general, as 51 subjects (0.9%) were underdiagnosed, and 61 subjects (1.1%) were overdiagnosed when using LLN as the reference diagnostic criterion. The underdiagnosed subjects were younger, had more symptoms, more exposure to biofuels and worse FEV 1 than the normal group; they also demonstrated a damaged cardiopulmonary reserve capacity and significant FEV 1 decline. Except for being older, the overdiagnosed subjects differed little from the normal group. Individual-dependent LLN appears to better reveal impacts on detecting airflow limitation. Participants underdiagnosed by GOLD criterion should be paid more attention. ChiCTR-ECS-13004110. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. ASTHMA, CHRONIC BRONCHITIS AND EMPHYSEMA—The Use of Intermittent Positive Pressure Breathing with Inspiratory Flow Rate Control: A Review of the Literature

    PubMed Central

    Sheldon, Gerard P.

    1963-01-01

    In chronic obstructive lung disease (asthma, chronic bronchitis, obstructive emphysema) there is a segmental reduction in the caliber of the airways, which always results in obstruction to air-flow. Increased airway resistance is a physiological expression of airway obstruction. The addition of inspiratory flow rate control to an intermittent positive pressure breathing device permits slow filling of a lung with obstructed airways, and is presented as a simple means of reducing the high pulmonary flow resistance and increasing the tidal volume. ImagesFigure 1. PMID:13977070

  12. Mechanical Design of a Performance Test Rig for the Turbine Air-Flow Task (TAFT)

    NASA Technical Reports Server (NTRS)

    Forbes, John C.; Xenofos, George D.; Farrow, John L.; Tyler, Tom; Williams, Robert; Sargent, Scott; Moharos, Jozsef

    2004-01-01

    To support development of the Boeing-Rocketdyne RS84 rocket engine, a full-flow, reaction turbine geometry was integrated into the NASA-MSFC turbine air-flow test facility. A mechanical design was generated which minimized the amount of new hardware while incorporating all test and instrumentation requirements. This paper provides details of the mechanical design for this Turbine Air-Flow Task (TAFT) test rig. The mechanical design process utilized for this task included the following basic stages: Conceptual Design. Preliminary Design. Detailed Design. Baseline of Design (including Configuration Control and Drawing Revision). Fabrication. Assembly. During the design process, many lessons were learned that should benefit future test rig design projects. Of primary importance are well-defined requirements early in the design process, a thorough detailed design package, and effective communication with both the customer and the fabrication contractors.

  13. Methane emissions and airflow patterns along longwall faces and through bleeder ventilation systems

    PubMed Central

    Schatzel, Steven J.; Dougherty, Heather N.

    2015-01-01

    The National Institute for Occupational Safety and Health (NIOSH) conducted an investigation of longwall face and bleeder ventilation systems using tracer gas experiments and computer network ventilation. The condition of gateroad entries, along with the caved material’s permeability and porosity changes as the longwall face advances, determine the resistance of the airflow pathways within the longwall’s worked-out area of the bleeder system. A series of field evaluations were conducted on a four-panel longwall district. Tracer gas was released at the mouth of the longwall section or on the longwall face and sampled at various locations in the gateroads inby the shield line. Measurements of arrival times and concentrations defined airflow/gas movements for the active/completed panels and the bleeder system, providing real field data to delineate these pathways. Results showed a sustained ability of the bleeder system to ventilate the longwall tailgate corner as the panels retreated. PMID:26925166

  14. Employment and activity limitations among adults with chronic obstructive pulmonary disease--United States, 2013.

    PubMed

    Wheaton, Anne G; Cunningham, Timothy J; Ford, Earl S; Croft, Janet B

    2015-03-27

    Chronic obstructive pulmonary disease (COPD) is a group of progressive respiratory conditions, including emphysema and chronic bronchitis, characterized by airflow obstruction and symptoms such as shortness of breath, chronic cough, and sputum production. COPD is an important contributor to mortality and disability in the United States. Healthy People 2020 has several COPD-related objectives,* including to reduce activity limitations among adults with COPD. To assess the state-level prevalence of COPD and the association of COPD with various activity limitations among U.S. adults, CDC analyzed data from the 2013 Behavioral Risk Factor Surveillance System (BRFSS). Among U.S. adults in all 50 states, the District of Columbia (DC), and two U.S. territories, 6.4% (an estimated 15.7 million adults) had been told by a physician or other health professional that they have COPD. Adults who reported having COPD were more likely to report being unable to work (24.3% versus 5.3%), having an activity limitation caused by health problems (49.6% versus 16.9%), having difficulty walking or climbing stairs (38.4% versus 11.3%), or using special equipment to manage health problems (22.1% versus 6.7%), compared with adults without COPD. Smokers who have been diagnosed with COPD are encouraged to quit smoking, which can slow the progression of the disease and reduce mobility impairment. In addition, COPD patients should consider participation in a pulmonary rehabilitation program that combines patient education and exercise training to address barriers to physical activity, such as respiratory symptoms and muscle wasting.

  15. Breathing life into dinosaurs: tackling challenges of soft-tissue restoration and nasal airflow in extinct species.

    PubMed

    Bourke, Jason M; Porter, W M Ruger; Ridgely, Ryan C; Lyson, Tyler R; Schachner, Emma R; Bell, Phil R; Witmer, Lawrence M

    2014-11-01

    The nasal region plays a key role in sensory, thermal, and respiratory physiology, but exploring its evolution is hampered by a lack of preservation of soft-tissue structures in extinct vertebrates. As a test case, we investigated members of the "bony-headed" ornithischian dinosaur clade Pachycephalosauridae (particularly Stegoceras validum) because of their small body size (which mitigated allometric concerns) and their tendency to preserve nasal soft tissues within their hypermineralized skulls. Hypermineralization directly preserved portions of the olfactory turbinates along with an internal nasal ridge that we regard as potentially an osteological correlate for respiratory conchae. Fossil specimens were CT-scanned, and nasal cavities were segmented and restored. Soft-tissue reconstruction of the nasal capsule was functionally tested in a virtual environment using computational fluid dynamics by running air through multiple models differing in nasal soft-tissue conformation: a bony-bounded model (i.e., skull without soft tissue) and then models with soft tissues added, such as a paranasal septum, a scrolled concha, a branched concha, and a model combining the paranasal septum with a concha. Deviations in fluid flow in comparison to a phylogenetically constrained sample of extant diapsids were used as indicators of missing soft tissue. Models that restored aspects of airflow found in extant diapsids, such as appreciable airflow in the olfactory chamber, were judged as more likely. The model with a branched concha produced airflow patterns closest to those of extant diapsids. These results from both paleontological observation and airflow modeling indicate that S. validum and other pachycephalosaurids could have had both olfactory and respiratory conchae. Although respiratory conchae have been linked to endothermy, such conclusions require caution in that our re-evaluation of the reptilian nasal apparatus indicates that respiratory conchae may be more widespread

  16. The Evolution of Unidirectional Pulmonary Airflow.

    PubMed

    Farmer, C G

    2015-07-01

    Conventional wisdom holds that the avian respiratory system is unique because air flows in the same direction through most of the gas-exchange tubules during both phases of ventilation. However, recent studies showing that unidirectional airflow also exists in crocodilians and lizards raise questions about the true phylogenetic distribution of unidirectional airflow, the selective drivers of the trait, the date of origin, and the functional consequences of this phenomenon. These discoveries suggest unidirectional flow was present in the common diapsid ancestor and are inconsistent with the traditional paradigm that unidirectional flow is an adaptation for supporting high rates of gas exchange. Instead, these discoveries suggest it may serve functions such as decreasing the work of breathing, decreasing evaporative respiratory water loss, reducing rates of heat loss, and facilitating crypsis. The divergence in the design of the respiratory system between unidirectionally ventilated lungs and tidally ventilated lungs, such as those found in mammals, is very old, with a minimum date for the divergence in the Permian Period. From this foundation, the avian and mammalian lineages evolved very different respiratory systems. I suggest the difference in design is due to the same selective pressure, expanded aerobic capacity, acting under different environmental conditions. High levels of atmospheric oxygen of the Permian Period relaxed selection for a thin blood-gas barrier and may have resulted in the homogeneous, broncho-alveolar design, whereas the reduced oxygen of the Mesozoic selected for a heterogeneous lung with an extremely thin blood-gas barrier. These differences in lung design may explain the puzzling pattern of ecomorphological diversification of Mesozoic mammals: all were small animals that did not occupy niches requiring a great aerobic capacity. The broncho-alveolar lung and the hypoxia of the Mesozoic may have restricted these mammals from exploiting

  17. Managing central venous obstruction in cystic fibrosis recipients--lung transplant considerations.

    PubMed

    Otani, Shinji; Westall, Glen P; Levvey, Bronwyn J; Marasco, Silvana; Lyon, Stuart; Snell, Gregory I

    2015-03-01

    The superior vena cava (SVC) syndrome in cystic fibrosis (CF) patients is rare, but presents unique challenges in the peri-transplant period. We reviewed our experience of SVC syndrome in CF recipients undergoing lung transplantation. This is a retrospective case series from a single center chart-review. SVC obstruction is defined by clinically significant stenosis or obstruction of the SVC as detected by contrast studies. We identified SVC obstruction in seven post-transplant cases and one pre-transplant case. All eight patients had previous or current history of indwelling central venous catheters. Three recipients experienced operative complications. Five of the seven recipients suffered at least one episode of post-operative SVC obstruction or bleeding despite prophylactic anticoagulation. At a median follow-up of 29 months, six of the seven patients transplanted are well. Strategies are available to minimize the risks of intra/peri-operative acute life-threatening SVC obstruction in CF patients. Copyright © 2014 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  18. Contam airflow models of three large buildings: Model descriptions and validation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Black, Douglas R.; Price, Phillip N.

    2009-09-30

    Airflow and pollutant transport models are useful for several reasons, including protection from or response to biological terrorism. In recent years they have been used for deciding how many biological agent samplers are needed in a given building to detect the release of an agent; to figure out where those samplers should be located; to predict the number of people at risk in the event of a release of a given size and location; to devise response strategies in the event of a release; to determine optimal trade-offs between sampler characteristics (such as detection limit and response time); and somore » on. For some of these purposes it is necessary to model a specific building of interest: if you are trying to determine optimal sampling locations, you must have a model of your building and not some different building. But for many purposes generic or 'prototypical' building models would suffice. For example, for determining trade-offs between sampler characteristics, results from one building will carry over other, similar buildings. Prototypical building models are also useful for comparing or testing different algorithms or computational pproaches: different researchers can use the same models, thus allowing direct comparison of results in a way that is not otherwise possible. This document discusses prototypical building models developed by the Airflow and Pollutant Transport Group at Lawrence Berkeley National Laboratory. The models are implemented in the Contam v2.4c modeling program, available from the National Institutes for Standards and Technology. We present Contam airflow models of three virtual buildings: a convention center, an airport terminal, and a multi-story office building. All of the models are based to some extent on specific real buildings. Our goal is to produce models that are realistic, in terms of approximate magnitudes, directions, and speeds of airflow and pollutant transport. The three models vary substantially in detail. The

  19. Relationship between Dysphagia and Exacerbations in Chronic Obstructive Pulmonary Disease: A Literature Review

    PubMed Central

    Steidl, Eduardo; Ribeiro, Carla Simone; Gonçalves, Bruna Franciele; Fernandes, Natália; Antunes, Vívian; Mancopes, Renata

    2014-01-01

    Introduction The literature presents studies correlating chronic obstructive pulmonary disease to dysphagia and suggesting that the aspiration laryngeal phenomenon related to changes in the pharyngeal phase contributes significantly to the exacerbation of symptoms of lung disease. Objectives This study aimed to conduct a literature review to identify the relation between dysphagia and exacerbations of chronic obstructive pulmonary disease. Data Synthesis We found 21 studies and included 19 in this review. The few studies that related to the subject agreed that the presence of dysphagia, due to lack of coordination between swallowing and breathing, may be one of the triggering factors of chronic obstructive pulmonary disease exacerbation. Conclusions The review noted that there is a relationship between dysphagia and exacerbations of chronic obstructive pulmonary disease, identified by studies demonstrating that the difficulties associated with swallowing may lead to exacerbation of the disease. There was difficulty in comparing studies by their methodological differences. More research is needed to clarify the relationship between dysphagia and exacerbations of chronic obstructive pulmonary disease, making it possible to develop multiprofessional treatment strategies for these patients, catered to specific needs due to the systemic manifestations of the disease. PMID:25992155

  20. Within-breath respiratory impedance and airway obstruction in patients with chronic obstructive pulmonary disease.

    PubMed

    Silva, Karla Kristine Dames da; Faria, Alvaro Camilo Dias; Lopes, Agnaldo José; Melo, Pedro Lopes de

    2015-07-01

    Recent work has suggested that within-breath respiratory impedance measurements performed using the forced oscillation technique may help to noninvasively evaluate respiratory mechanics. We investigated the influence of airway obstruction on the within-breath forced oscillation technique in smokers and chronic obstructive pulmonary disease patients and evaluated the contribution of this analysis to the diagnosis of chronic obstructive pulmonary disease. Twenty healthy individuals and 20 smokers were assessed. The study also included 74 patients with stable chronic obstructive pulmonary disease. We evaluated the mean respiratory impedance (Zm) as well as values for the inspiration (Zi) and expiration cycles (Ze) at the beginning of inspiration (Zbi) and expiration (Zbe), respectively. The peak-to-peak impedance (Zpp=Zbe-Zbi) and the respiratory cycle dependence (ΔZrs=Ze-Zi) were also analyzed. The diagnostic utility was evaluated by investigating the sensitivity, the specificity and the area under the receiver operating characteristic curve. ClinicalTrials.gov: NCT01888705. Airway obstruction increased the within-breath respiratory impedance parameters that were significantly correlated with the spirometric indices of airway obstruction (R=-0.65, p<0.0001). In contrast to the control subjects and the smokers, the chronic obstructive pulmonary disease patients presented significant expiratory-inspiratory differences (p<0.002). The adverse effects of moderate airway obstruction were detected based on the Zpp with an accuracy of 83%. Additionally, abnormal effects in severe and very severe patients were detected based on the Zm, Zi, Ze, Zbe, Zpp and ΔZrs with a high degree of accuracy (>90%). We conclude the following: (1) chronic obstructive pulmonary disease introduces higher respiratory cycle dependence, (2) this increase is proportional to airway obstruction, and (3) the within-breath forced oscillation technique may provide novel parameters that facilitate the

  1. Turbojet-exhaust-nozzle secondary-airflow pumping as an exit control of an inlet-stability bypass system for a Mach 2.5 axisymmetric mixed-compression inlet. [Lewis 10- by 10-ft. supersonic wind tunnel test

    NASA Technical Reports Server (NTRS)

    Sanders, B. W.

    1980-01-01

    The throat of a Mach 2.5 inlet that was attached to a turbojet engine was fitted with large, porous bleed areas to provide a stability bypass system that would allow a large, stable airflow range. Exhaust-nozzle, secondary-airflow pumping was used as the exit control for the stability bypass airflow. Propulsion system response and stability bypass performance were obtained for several transient airflow disturbances, both internal and external. Internal airflow disturbances included reductions in overboard bypass airflow, power lever angle, and primary-nozzle area, as well as compressor stall. Nozzle secondary pumping as a stability bypass exit control can provide the inlet with a large stability margin with no adverse effects on propulsion system performance.

  2. Intestinal Pseudo-Obstruction

    MedlinePlus

    ... condition as adults. Intestinal pseudo-obstruction may be acute, occurring suddenly and lasting a short time, or it may be chronic, or long lasting. Acute colonic pseudo-obstruction, also called Ogilvie syndrome or ...

  3. Using Coupled Energy, Airflow and IAQ Software (TRNSYS/CONTAM) to Evaluate Building Ventilation Strategies.

    PubMed

    Dols, W Stuart; Emmerich, Steven J; Polidoro, Brian J

    2016-03-01

    Building energy analysis tools are available in many forms that provide the ability to address a broad spectrum of energy-related issues in various combinations. Often these tools operate in isolation from one another, making it difficult to evaluate the interactions between related phenomena and interacting systems, forcing oversimplified assumptions to be made about various phenomena that could otherwise be addressed directly with another tool. One example of such interdependence is the interaction between heat transfer, inter-zone airflow and indoor contaminant transport. In order to better address these interdependencies, the National Institute of Standards and Technology (NIST) has developed an updated version of the multi-zone airflow and contaminant transport modelling tool, CONTAM, along with a set of utilities to enable coupling of the full CONTAM model with the TRNSYS simulation tool in a more seamless manner and with additional capabilities that were previously not available. This paper provides an overview of these new capabilities and applies them to simulating a medium-size office building. These simulations address the interaction between whole-building energy, airflow and contaminant transport in evaluating various ventilation strategies including natural and demand-controlled ventilation. CONTAM has been in practical use for many years allowing building designers, as well as IAQ and ventilation system analysts, to simulate the complex interactions between building physical layout and HVAC system configuration in determining building airflow and contaminant transport. It has been widely used to design and analyse smoke management systems and evaluate building performance in response to chemical, biological and radiological events. While CONTAM has been used to address design and performance of buildings implementing energy conserving ventilation systems, e.g., natural and hybrid, this new coupled simulation capability will enable users to apply the

  4. Using Coupled Energy, Airflow and IAQ Software (TRNSYS/CONTAM) to Evaluate Building Ventilation Strategies

    PubMed Central

    Dols, W. Stuart.; Emmerich, Steven J.; Polidoro, Brian J.

    2016-01-01

    Building energy analysis tools are available in many forms that provide the ability to address a broad spectrum of energy-related issues in various combinations. Often these tools operate in isolation from one another, making it difficult to evaluate the interactions between related phenomena and interacting systems, forcing oversimplified assumptions to be made about various phenomena that could otherwise be addressed directly with another tool. One example of such interdependence is the interaction between heat transfer, inter-zone airflow and indoor contaminant transport. In order to better address these interdependencies, the National Institute of Standards and Technology (NIST) has developed an updated version of the multi-zone airflow and contaminant transport modelling tool, CONTAM, along with a set of utilities to enable coupling of the full CONTAM model with the TRNSYS simulation tool in a more seamless manner and with additional capabilities that were previously not available. This paper provides an overview of these new capabilities and applies them to simulating a medium-size office building. These simulations address the interaction between whole-building energy, airflow and contaminant transport in evaluating various ventilation strategies including natural and demand-controlled ventilation. Practical Application CONTAM has been in practical use for many years allowing building designers, as well as IAQ and ventilation system analysts, to simulate the complex interactions between building physical layout and HVAC system configuration in determining building airflow and contaminant transport. It has been widely used to design and analyse smoke management systems and evaluate building performance in response to chemical, biological and radiological events. While CONTAM has been used to address design and performance of buildings implementing energy conserving ventilation systems, e.g., natural and hybrid, this new coupled simulation capability will

  5. Effects of Airflow and Changing Humidity on the Aerosolization of Respirable Fungal Fragments and Conidia of Botrytis cinerea

    PubMed Central

    2012-01-01

    The purpose of this study was to investigate the aerosolization of particles (micro- and macroconidia and fragments) from Botrytis cinerea cultures in relation to potential human inhalation in indoor environments. The influence of the following factors on the aerosolization of B. cinerea particles was studied: exposure to airflow, relative humidity (rh), changing rh, and plant or building materials. The aerodynamic diameter (da) and the respirable fraction of the aerosolized particles were determined. Conidia and fragments of B. cinerea were not aerosolized as a response to a decrease in the rh. In contrast, both micro- and macroconidia and fungal fragments were aerosolized when exposed to an airflow of 1.5 m s−1 or 0.5 m s−1. Significantly more particles of microconidial size and fragment size were aerosolized at a low rh (18 to 40% rh) than at a higher rh (60 to 80% rh) when cultures were exposed to airflow. The size of the respirable fraction of the aerosolized particles was dependent on the rh but not on the growth material. At high rh, about 30% of the aerosolized particles were of respirable size, while at low rh, about 70% were of respirable size. During low rh, more fungal (1→3)-β-d-glucan and chitinase were aerosolized than during high rh. In conclusion, exposure to external physical forces such as airflow is necessary for the aerosolization of particles from B. cinerea. The amount and size distribution are highly affected by the rh, and more particles of respirable sizes were aerosolized at low rh than at high rh. PMID:22447608

  6. Dynamic upper airway changes during sleep in patients with obstructive sleep apnea syndrome.

    PubMed

    Chuang, Li-Pang; Chen, Ning-Hung; Li, Hsueh-Yu; Lin, Shih-Wei; Chou, Yu-Ting; Wang, Chao-Jan; Liao, Yu-Fang; Tsai, Ying-Huang

    2009-12-01

    The narrowing pattern of the upper airway in obstructive sleep apnea patients may be different in sleep as compared with awake. Three different types of obstruction were observed in these subjects during drug-induced sleep. The different obstruction pattern during drug-induced sleep suggests that different strategies should be selected in upper airway management. To identify the sites of narrowing and evaluate dynamic upper airway movement in patients with obstructive sleep apnea syndrome (OSAS) while awake and asleep. This study included 10 patients treated for OSAS between August 2003 and June 2004. Overnight polysomnography was performed on all patients. Parameters including gender, age, neck circumference, and body mass index were recorded. Ultra-fast MRI during awake and drug-induced sleep was arranged to evaluate the dynamic motion of the upper airway. The narrowing pattern of the upper airway during awake differed from the narrowing pattern during drug-induced sleep in 3 of 10 subjects. Three different types, palatal obstruction, combined upper and lower pharyngeal obstruction, and circumferential obstruction of the upper airway, were observed in these patients during drug-induced sleep.

  7. Three-dimensional ultrasound measurements of carotid vessel wall and plaque thickness and their relationship with pulmonary abnormalities in ex-smokers without airflow limitation.

    PubMed

    Cheng, Jieyu; Pike, Damien; Chow, Tommy W S; Kirby, Miranda; Parraga, Grace; Chiu, Bernard

    2016-09-01

    The relationship between carotid disease and modestly abnormal airflow in ex-smokers without chronic obstructive pulmonary disease (COPD) is not well-understood. We generated 3D ultrasound measurements of carotid vessel-wall-plus-plaque thickness (VWT) and vessel wall volume (VWV) to quantify and evaluate such carotid ultrasound measurements in ex- and never-smokers without airflow limitation. These patients did not fulfill the diagnostic criteria for COPD. We also investigated the relationship of carotid atherosclerosis with pulmonary phenotypes of COPD. We evaluated 61 subjects without a clinical diagnosis of pulmonary or vascular diseases including 34 never-smokers (72 ± 6 year) and 27 ex-smokers (73 ± 9 year). We measured mean VWT ([Formula: see text]) and mean VWT specific to carotid regions-of-interest ([Formula: see text]) and evaluated potential differences between ex- and never-smokers. Carotid ultrasound and pulmonary disease measurement relationships were also evaluated using correlation coefficients (r) and multivariate regression analyses. Ex-smokers had a significantly greater [Formula: see text] (p = 0.003) and [Formula: see text] (p < 0.00001) than never-smokers, whereas a significant difference between the two groups was not detected by VWV (p = 1.0). There were significant correlations between the ventilation defect percent (VDP) measured by MRI with [Formula: see text] (r = 0.42, p = 0.001) and [Formula: see text] (r = 0.56, p = 0.00001). Multivariate regression models showed that VDP significantly predicted [Formula: see text] (β = 0.38, p = 0.004) and [Formula: see text] (β = 0.50, p = 0.00001). VWT-based measurements detected differences in vessel-wall-plus-plaque burden in ex- and never-smokers, which were not revealed using VWV. There were significant correlations between cardiovascular and pulmonary disease biomarkers in these ex-smokers who did not have a clinical diagnosis of

  8. Preoperative Obstructive Sleep Apnea Screening in Gynecologic Oncology Patients.

    PubMed

    Harrison, Ross F; Medlin, Erin E; Petersen, Chase B; Rose, Stephen L; Hartenbach, Ellen M; Kushner, David M; Spencer, Ryan J; Rice, Laurel W; Al-Niaimi, Ahmed N

    2018-05-21

    Women with a gynecologic cancer tend to be older, obese, and postmenopausal, characteristics that are associated with an increased risk for obstructive sleep apnea. However, there is limited investigation regarding the condition's prevalence in this population or its impact on postoperative outcomes. In other surgical populations, patients with obstructive sleep apnea have been observed to be at increased risk for adverse postoperative events. To estimate the prevalence of obstructive sleep apnea among gynecologic oncology patients undergoing elective surgery and to investigate for a relationship between obstructive sleep apnea and postoperative outcomes. Patients referred to an academic gynecologic oncology practice were approached for enrollment in this prospective, observational study. Patients were considered eligible for study enrollment if they were scheduled for a non-emergent inpatient surgery and could provide informed consent. Enrolled patients were evaluated for a preexisting diagnosis of obstructive sleep apnea. Those without a prior diagnosis were screened using the validated, 4-item STOP [i.e. Snore loudly, daytime Tiredness, Observed apnea, elevated blood Pressure] questionnaire. All patients who screened positive for obstructive sleep apnea were referred for polysomnography. The primary outcome was the prevalence of women with obstructive sleep apnea or those who screened at high risk for the condition. Secondary outcomes examined the correlation between body mass index (kg/m 2 ) with obstructive sleep apnea and assessed for a relationship between obstructive sleep apnea and postoperative outcomes. Over a 22-month accrual period, 383 eligible patients were consecutively approached to participate in the study. A cohort of 260 patients were enrolled. A total of 33/260 patients (13%) were identified as having a previous diagnosis of obstructive sleep apnea. An additional 66/260 (25%) screened at risk for the condition using the STOP questionnaire. Of

  9. Murine model of long term obstructive jaundice

    PubMed Central

    Aoki, Hiroaki; Aoki, Masayo; Yang, Jing; Katsuta, Eriko; Mukhopadhyay, Partha; Ramanathan, Rajesh; Woelfel, Ingrid A.; Wang, Xuan; Spiegel, Sarah; Zhou, Huiping; Takabe, Kazuaki

    2016-01-01

    Background With the recent emergence of conjugated bile acids as signaling molecules in cancer, a murine model of obstructive jaundice by cholestasis with long-term survival is in need. Here, we investigated the characteristics of 3 murine models of obstructive jaundice. Methods C57BL/6J mice were used for total ligation of the common bile duct (tCL), partial common bile duct ligation (pCL), and ligation of left and median hepatic bile duct with gallbladder removal (LMHL) models. Survival was assessed by Kaplan-Meier method. Fibrotic change was determined by Masson-Trichrome staining and Collagen expression. Results 70% (7/10) of tCL mice died by Day 7, whereas majority 67% (10/15) of pCL mice survived with loss of jaundice. 19% (3/16) of LMHL mice died; however, jaundice continued beyond Day 14, with survival of more than a month. Compensatory enlargement of the right lobe was observed in both pCL and LMHL models. The pCL model demonstrated acute inflammation due to obstructive jaundice 3 days after ligation but jaundice rapidly decreased by Day 7. The LHML group developed portal hypertension as well as severe fibrosis by Day 14 in addition to prolonged jaundice. Conclusion The standard tCL model is too unstable with high mortality for long-term studies. pCL may be an appropriate model for acute inflammation with obstructive jaundice but long term survivors are no longer jaundiced. The LHML model was identified to be the most feasible model to study the effect of long-term obstructive jaundice. PMID:27916350

  10. Endosonography for suspected obstructive jaundice with no definite pathology on ultrasonography.

    PubMed

    Chen, Chien-Hua; Yang, Chi-Chieh; Yeh, Yung-Hsiang; Yang, Tsang; Chung, Tieh-Chi

    2015-09-01

    Ultrasonography (US) cannot demonstrate all the etiologies of biliary tract dilatation in patients with jaundice. Thus, we evaluated the etiologic yield of endosonography (EUS) for suspected obstructive jaundice when no definite pathology was found on US. Additionally, we sought to identify the predictors of the most common etiologies. We performed a retrospective review of 123 consecutive patients who had undergone EUS for suspected obstructive jaundice when no definite pathology was identified on US. The most common diagnoses included no pathological obstruction (n = 43), pancreatobiliary malignancy (n = 41), and choledocholithiasis (n = 28). Pancreatobiliary malignancy was associated with common bile duct (CBD) dilatation, and fever and elevated alanine aminotransferase were predictors of choledocholithiasis (p < 0.05). The accuracy of EUS was 95.9% (118/123) for overall cause of suspected obstructive jaundice, 100% (40/40) for no pathological finding, 100% (23/23) for ampullary cancer, 100% (13/13) for pancreatic cancer, 75% (3/4) for CBD cancer, and 92.9% (26/28) for choledocholithiasis, respectively. Besides the two patients with focal chronic pancreatitis misdiagnosed as with pancreatic cancer, EUS missed the lesions in one CBD cancer patient and two patients with choledocholithiasis. The overall accuracy of EUS in ascertaining pancreatobiliary malignancy and choledocholithiasis was comparable (97.6%, 40/41 vs. 92.9%, 26/28; p > 0.05). Marked CBD dilatation (≥12 mm) should remind us of the high risk of malignancy, and the presence of CBD dilatation and fever is suggestive of choledocholithiasis. Negative EUS findings cannot assure any pathological obstruction in patients with clinically suspected obstructive jaundice. Copyright © 2013. Published by Elsevier B.V.

  11. Interactions of bluff-body obstacles with turbulent airflows affecting evaporative fluxes from porous surfaces

    NASA Astrophysics Data System (ADS)

    Haghighi, Erfan; Or, Dani

    2015-11-01

    Bluff-body obstacles interacting with turbulent airflows are common in many natural and engineering applications (from desert pavement and shrubs over natural surfaces to cylindrical elements in compact heat exchangers). Even with obstacles of simple geometry, their interactions within turbulent airflows result in a complex and unsteady flow field that affects surface drag partitioning and transport of scalars from adjacent evaporating surfaces. Observations of spatio-temporal thermal patterns on evaporating porous surfaces adjacent to bluff-body obstacles depict well-defined and persistent zonation of evaporation rates that were used to construct a simple mechanistic model for surface-turbulence interactions. Results from evaporative drying of sand surfaces with isolated cylindrical elements (bluff bodies) subjected to constant turbulent airflows were in good agreement with model predictions for localized exchange rates. Experimental and theoretical results show persistent enhancement of evaporative fluxes from bluff-rough surfaces relative to smooth flat surfaces under similar conditions. The enhancement is attributed to formation of vortices that induce a thinner boundary layer over part of the interacting surface footprint. For a practical range of air velocities (0.5-4.0 m/s), low-aspect ratio cylindrical bluff elements placed on evaporating sand surfaces enhanced evaporative mass losses (relative to a flat surface) by up to 300% for high density of elements and high wind velocity, similar to observations reported in the literature. Concepts from drag partitioning were used to generalize the model and upscale predictions to evaporation from surfaces with multiple obstacles for potential applications to natural bluff-rough surfaces.

  12. Non-atopic males with adult onset asthma are at risk of persistent airflow limitation.

    PubMed

    Amelink, M; de Nijs, S B; Berger, M; Weersink, E J; ten Brinke, A; Sterk, P J; Bel, E H

    2012-05-01

    Patients with asthma have on average a more rapid decline in FEV (1) as compared with the general population. Recent cluster analysis has revealed different asthma phenotypes that can be distinguished by age of onset and reversibility of airflow limitation. This study aimed at detecting risk factors associated with persistent airflow limitation in patients with the adult onset asthma phenotype. We recruited 88 patients with adult onset (≥ 18 years) asthma from an academic pulmonary outpatient clinic in the Netherlands. The associations of age, age of asthma onset, asthma duration, gender, race, atopy, smoking pack-years, BMI, use of oral corticosteroids with post-bronchodilator FEV (1) /FVC were investigated. Multiple linear regression analysis showed an association of absence of atopy (r = -0.27, B = -0.26, P = 0.01) and male gender (r = 0.31, B = 0.30, P = 0.004) with post-bronchodilator FEV (1) /FVC. Multiple logistic regression analysis showed that male patients were 10.8 (CI: 2.6-45.2) times the odds than women to have an FEV (1) /FVC < 0.7, and non-atopic patients were 5.2 (CI: 1.3-20.3) times the odds to have an FEV (1) /FVC < 0.7 than atopic patients. We conclude that in patients with adult onset asthma, male gender and absence of atopy are associated with persistent airflow limitation. This might suggest that amongst patients with adult onset asthma, non-atopic male patients are at increased risk of accelerated decline in lung function. © 2012 Blackwell Publishing Ltd.

  13. Coupling fast fluid dynamics and multizone airflow models in Modelica Buildings library to simulate the dynamics of HVAC systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tian, Wei; Sevilla, Thomas Alonso; Zuo, Wangda

    Historically, multizone models are widely used in building airflow and energy performance simulations due to their fast computing speed. However, multizone models assume that the air in a room is well mixed, consequently limiting their application. In specific rooms where this assumption fails, the use of computational fluid dynamics (CFD) models may be an alternative option. Previous research has mainly focused on coupling CFD models and multizone models to study airflow in large spaces. While significant, most of these analyses did not consider the coupled simulation of the building airflow with the building's Heating, Ventilation, and Air-Conditioning (HVAC) systems. Thismore » paper tries to fill the gap by integrating the models for HVAC systems with coupled multizone and CFD simulations for airflows, using the Modelica simul ation platform. To improve the computational efficiency, we incorporated a simplified CFD model named fast fluid dynamics (FFD). We first introduce the data synchronization strategy and implementation in Modelica. Then, we verify the implementation using two case studies involving an isothermal and a non-isothermal flow by comparing model simulations to experiment data. Afterward, we study another three cases that are deemed more realistic. This is done by attaching a variable air volume (VAV) terminal box and a VAV system to previous flows to assess the capability of the models in studying the dynamic control of HVAC systems. Finally, we discuss further research needs on the coupled simulation using the models.« less

  14. Spectral analysis of bowel sounds in intestinal obstruction using an electronic stethoscope.

    PubMed

    Ching, Siok Siong; Tan, Yih Kai

    2012-09-07

    To determine the value of bowel sounds analysis using an electronic stethoscope to support a clinical diagnosis of intestinal obstruction. Subjects were patients who presented with a diagnosis of possible intestinal obstruction based on symptoms, signs, and radiological findings. A 3M™ Littmann(®) Model 4100 electronic stethoscope was used in this study. With the patients lying supine, six 8-second recordings of bowel sounds were taken from each patient from the lower abdomen. The recordings were analysed for sound duration, sound-to-sound interval, dominant frequency, and peak frequency. Clinical and radiological data were reviewed and the patients were classified as having either acute, subacute, or no bowel obstruction. Comparison of bowel sound characteristics was made between these subgroups of patients. In the presence of an obstruction, the site of obstruction was identified and bowel calibre was also measured to correlate with bowel sounds. A total of 71 patients were studied during the period July 2009 to January 2011. Forty patients had acute bowel obstruction (27 small bowel obstruction and 13 large bowel obstruction), 11 had subacute bowel obstruction (eight in the small bowel and three in large bowel) and 20 had no bowel obstruction (diagnoses of other conditions were made). Twenty-five patients received surgical intervention (35.2%) during the same admission for acute abdominal conditions. A total of 426 recordings were made and 420 recordings were used for analysis. There was no significant difference in sound-to-sound interval, dominant frequency, and peak frequency among patients with acute bowel obstruction, subacute bowel obstruction, and no bowel obstruction. In acute large bowel obstruction, the sound duration was significantly longer (median 0.81 s vs 0.55 s, P = 0.021) and the dominant frequency was significantly higher (median 440 Hz vs 288 Hz, P = 0.003) when compared to acute small bowel obstruction. No significant difference was seen

  15. Spectral analysis of bowel sounds in intestinal obstruction using an electronic stethoscope

    PubMed Central

    Ching, Siok Siong; Tan, Yih Kai

    2012-01-01

    AIM: To determine the value of bowel sounds analysis using an electronic stethoscope to support a clinical diagnosis of intestinal obstruction. METHODS: Subjects were patients who presented with a diagnosis of possible intestinal obstruction based on symptoms, signs, and radiological findings. A 3M™ Littmann® Model 4100 electronic stethoscope was used in this study. With the patients lying supine, six 8-second recordings of bowel sounds were taken from each patient from the lower abdomen. The recordings were analysed for sound duration, sound-to-sound interval, dominant frequency, and peak frequency. Clinical and radiological data were reviewed and the patients were classified as having either acute, subacute, or no bowel obstruction. Comparison of bowel sound characteristics was made between these subgroups of patients. In the presence of an obstruction, the site of obstruction was identified and bowel calibre was also measured to correlate with bowel sounds. RESULTS: A total of 71 patients were studied during the period July 2009 to January 2011. Forty patients had acute bowel obstruction (27 small bowel obstruction and 13 large bowel obstruction), 11 had subacute bowel obstruction (eight in the small bowel and three in large bowel) and 20 had no bowel obstruction (diagnoses of other conditions were made). Twenty-five patients received surgical intervention (35.2%) during the same admission for acute abdominal conditions. A total of 426 recordings were made and 420 recordings were used for analysis. There was no significant difference in sound-to-sound interval, dominant frequency, and peak frequency among patients with acute bowel obstruction, subacute bowel obstruction, and no bowel obstruction. In acute large bowel obstruction, the sound duration was significantly longer (median 0.81 s vs 0.55 s, P = 0.021) and the dominant frequency was significantly higher (median 440 Hz vs 288 Hz, P = 0.003) when compared to acute small bowel obstruction. No significant

  16. Poppet valve control of throat stability bypass to increase stable airflow range of a Mach 2.5. inlet with 60 percent internal contraction

    NASA Technical Reports Server (NTRS)

    Mitchell, G. A.; Sanders, B. W.

    1975-01-01

    The throat of a Mach 2.5 inlet with a coldpipe termination was fitted with a stability-bypass system. System variations included several stability bypass entrance configurations. Poppet valves controlled the bypass airflow. The inlet stable airflow range achieved with each configuration was determined for both steady state conditions and internal pulse transients. Results are compared with those obtained without a stability bypass system. Transient results were also obtained for the inlet with a choke point at the diffuser exit and for the inlet with large and small stability bypass plenum volumes. Poppet valves at the stability bypass exit provided the inlet with a stable airflow range of 20 percent or greater at all static and transient conditions.

  17. Derivation and validation of a composite index of severity in chronic obstructive pulmonary disease: the DOSE Index.

    PubMed

    Jones, Rupert C; Donaldson, Gavin C; Chavannes, Niels H; Kida, Kozui; Dickson-Spillmann, Maria; Harding, Samantha; Wedzicha, Jadwiga A; Price, David; Hyland, Michael E

    2009-12-15

    Chronic obstructive pulmonary disease (COPD) is increasingly recognized as a multicomponent disease with systemic consequences and effects on quality of life. Single measures such as lung function provide a limited reflection of how the disease affects patients. Composite measures have the potential to account for many of the facets of COPD. To derive and validate a multicomponent assessment tool of COPD severity that is applicable to all patients and health care settings. The index was derived using data from 375 patients with COPD in primary care. Regression analysis led to a model explaining 48% of the variance in health status as measured by the Clinical COPD Questionnaire with four components: dyspnea (D), airflow obstruction (O), smoking status (S), and exacerbation frequency (E). The DOSE Index was validated in cross-sectional and longitudinal samples in various health care settings in Holland, Japan, and the United Kingdom. The DOSE Index correlated with health status in all data sets. A high DOSE Index score (> or = 4) was associated with a greater risk of hospital admission (odds ratio, 8.3 [4.1-17]) or respiratory failure (odds ratio, 7.8 [3.4-18.3]). The index predicted exacerbations in the subsequent year (P < or = 0.014). The DOSE Index is a simple, valid tool for assessing the severity of COPD. The index is related to a range of clinically important outcomes such as health care consumption and predicts future events.

  18. An RGS4-mediated phenotypic switch of bronchial smooth muscle cells promotes fixed airway obstruction in asthma.

    PubMed

    Damera, Gautam; Druey, Kirk M; Cooper, Philip R; Krymskaya, Vera P; Soberman, Roy J; Amrani, Yassine; Hoshi, Toshinori; Brightling, Christopher E; Panettieri, Reynold A

    2012-01-01

    In severe asthma, bronchodilator- and steroid-insensitive airflow obstruction develops through unknown mechanisms characterized by increased lung airway smooth muscle (ASM) mass and stiffness. We explored the role of a Regulator of G-protein Signaling protein (RGS4) in the ASM hyperplasia and reduced contractile capacity characteristic of advanced asthma. Using immunocytochemical staining, ASM expression of RGS4 was determined in endobronchial biopsies from healthy subjects and those from subjects with mild, moderate and severe asthma. Cell proliferation assays, agonist-induced calcium mobilization and bronchoconstriction were determined in cultured human ASM cells and in human precision cut lung slices. Using gain- and loss-of-function approaches, the precise role of RGS proteins was determined in stimulating human ASM proliferation and inhibiting bronchoconstriction. RGS4 expression was restricted to a subpopulation of ASM and was specifically upregulated by mitogens, which induced a hyperproliferative and hypocontractile ASM phenotype similar to that observed in recalcitrant asthma. RGS4 expression was markedly increased in bronchial smooth muscle of patients with severe asthma, and expression correlated significantly with reduced pulmonary function. Whereas RGS4 inhibited G protein-coupled receptor (GPCR)-mediated bronchoconstriction, unexpectedly RGS4 was required for PDGF-induced proliferation and sustained activation of PI3K, a mitogenic signaling molecule that regulates ASM proliferation. These studies indicate that increased RGS4 expression promotes a phenotypic switch of ASM, evoking irreversible airway obstruction in subjects with severe asthma.

  19. Pancreatic Calculus Causing Biliary Obstruction: Endoscopic Therapy for a Rare Initial Presentation of Chronic Pancreatitis.

    PubMed

    Shetty, Anurag J; Pai, C Ganesh; Shetty, Shiran; Balaraju, Girisha

    2015-09-01

    Biliary obstruction in chronic calcific pancreatitis (CCP) is often caused by inflammatory or fibrotic strictures of the bile duct, carcinoma of head of pancreas or less commonly by compression from pseudocysts. Pancreatic calculi causing ampullary obstruction and leading to obstructive jaundice is extremely rare. The medical records of all patients with CCP or biliary obstruction who underwent endoscopic retrograde cholangiopancreatography (ERCP) over 4 years between 2010-2014 at Kasturba Medical College, Manipal were analyzed. Five patients of CCP with impacted pancreatic calculi at the ampulla demonstrated during ERCP were identified. All 5 presented with biliary obstruction and were incidentally detected to have CCP when evaluated for the same; 3 patients had features of cholangitis. All the patients were managed successfully by endoscopic papillotomy and extraction of pancreatic calculi from the ampulla with resolution of biliary obstruction. Pancreatic calculus causing ampullary obstruction, though very rare, should be considered as a possibility in patients with CCP complicated by biliary obstruction. Endoscopic therapy is affective in the resolution of biliary obstruction in such patients.

  20. Dynamic response of a Mach 2.5 axisymmetric inlet and turbojet engine with a poppet-value controlled inlet stability bypass system when subjected to internal and external airflow transients

    NASA Technical Reports Server (NTRS)

    Sanders, B. W.

    1980-01-01

    The throat of a Mach 2.5 inlet that was attached to a turbojet engine was fitted with a poppet-valve-controlled stability bypass system that was designed to provide a large, stable airflow range. Propulsion system response and stability bypass performance were determined for several transient airflow disturbances, both internal and external. Internal airflow disturbances included reductions in overboard bypass airflow, power lever angle, and primary-nozzle area as well as compressor stall. For reference, data are also included for a conventional, fixed-exit bleed system. The poppet valves greatly increased inlet stability and had no adverse effects on propulsion system performance. Limited unstarted-inlet bleed performance data are presented.

  1. Association of incidental emphysema with annual lung function decline and future development of airflow limitation

    PubMed Central

    Koo, Hyeon-Kyoung; Jin, Kwang Nam; Kim, Deog Kyeom; Chung, Hee Soon; Lee, Chang-Hoon

    2016-01-01

    Objectives Emphysema is one of the prognostic factors for rapid lung function decline in patients with COPD, but the impact of incidentally detected emphysema on population without spirometric abnormalities has not been evaluated. This study aimed to determine whether emphysema detected upon computed tomography (CT) screening would accelerate the rate of lung function decline and influence the possibility of future development of airflow limitation in a population without spirometric abnormalities. Materials and methods Subjects who participated in a routine screening for health checkup and follow-up pulmonary function tests for at least 3 years between 2004 and 2010 were retrospectively enrolled. The percentage of low-attenuation area below −950 Hounsfield units (%LAA−950) was calculated automatically. A calculated value of %LAA−950 that exceeded 10% was defined as emphysema. Adjusted annual lung function decline was analyzed using random-slope, random-intercept mixed linear regression models. Results A total of 628 healthy subjects within the normal range of spriometric values were included. Multivariable analysis showed that the emphysema group exhibited a faster decline in forced vital capacity (−33.9 versus −18.8 mL/year; P=0.02). Emphysema was not associated with the development of airflow limitation during follow-up. Conclusion Incidental emphysema quantified using CT scan was significantly associated with a more rapid decline in forced vital capacity in the population with normative spirometric values. However, an association between emphysema and future development of airflow limitation was not observed. PMID:26893550

  2. An analysis of heat removal during cryogen spray cooling and effects of simultaneous airflow application.

    PubMed

    Torres, J H; Tunnell, J W; Pikkula, B M; Anvari, B

    2001-01-01

    Cryogen spray cooling (CSC) is a method used to protect the epidermis from non-specific thermal injury that may occur as a result of various dermatological laser procedures. However, better understanding of cryogen deposition and skin thermal response to CSC is needed to optimize the technique. Temperature measurements and video imaging were carried out on an epoxy phantom as well as human skin during CSC with and without simultaneous application of airflow which was intended to accelerate cryogen evaporation from the substrate surface. An inverse thermal conduction model was used to estimate heat flux and total heat removed. Lifetime of the cryogen film deposited on the surface of skin and epoxy phantom lasted several hundred milliseconds beyond the spurt, but could be reduced to the spurt duration by application of airflow. Values over 100 J/cm(3) were estimated for volumetric heat removed from the epidermis using CSC. "Film cooling" instead of "evaporative cooling" appears to be the dominant mode of CSC on skin. Estimated values of heat removed from the epidermis suggest that a cryogen spurt as long as 200 milliseconds is required to counteract heat generated by high laser fluences (e.g., in treatment of port wine stains) in patients with high concentration of epidermal melanin. Additional cooling beyond spurt termination can be avoided by simultaneous application of airflow, although it is unclear at the moment if avoiding the additional cooling would be beneficial in the actual clinical situation. Copyright 2001 Wiley-Liss, Inc.

  3. Quality of life in smokers: focus on functional limitations rather than on lung function?

    PubMed Central

    Geijer, Roeland MM; Sachs, Alfred PE; Verheij, Theo JM; Kerstjens, Huib AM; Kuyvenhoven, Marijke M; Hoes, Arno W

    2007-01-01

    Background The Global Initiative for Chronic Obstructive Lung Disease (GOLD) classification of severity of chronic obstructive pulmonary disease (COPD) is based solely on obstruction and does not capture physical functioning. The hypothesis that the Medical Research Council (MRC) dyspnoea scale would correlate better with quality of life than the level of airflow limitation was examined. Aim To study the associations between quality of life in smokers and limitations in physical functioning (MRC dyspnoea scale) and, quality of life and airflow limitation (GOLD COPD stages). Design Cross-sectional study. Setting The city of IJsselstein, a small town in the centre of The Netherlands. Method Male smokers aged 40–65 years without a prior diagnosis of COPD and enlisted with a general practice, participated in this study. Quality of life was assessed by means of a generic (SF–36) and a disease-specific, questionnaire (QOLRIQ). Results A total of 395 subjects (mean age 55.4 years, pack years 27.1) performed adequate spirometry and completed the questionnaires. Limitations of physical functioning according to the MRC dyspnoea scale were found in 25.1 % (99/395) of the participants and airflow limitation in 40.2% (159/395). The correlations of limitations of physical functioning with all quality-of-life components were stronger than the correlations of all quality-of-life subscales with the severity of airflow limitation. Conclusion In middle-aged smokers the correlation of limitations of physical functioning (MRC dyspnoea scale) with quality of life was stronger than the correlation of the severity of airflow limitation with quality of life. Future staging systems of severity of COPD should capture this and not rely on forced expiratory volume in one second (FEV1) alone. PMID:17550673

  4. COPD prevalence in a random population survey: a matter of definition.

    PubMed

    Shirtcliffe, P; Weatherall, M; Marsh, S; Travers, J; Hansell, A; McNaughton, A; Aldington, S; Muellerova, H; Beasley, R

    2007-08-01

    A recent American Thoracic Society and European Respiratory Society joint Task Force report recommends using a lower limit of normal (LLN) of forced expiratory volume in one second/forced vital capacity as opposed to a fixed ratio of <0.7 to diagnose airflow obstruction, in order to reduce false positive diagnoses of chronic obstructive pulmonary disease (COPD) as defined by the Global Initiative for Obstructive Lung Disease (GOLD). To date, there is no reliable spirometry-based prevalence data for COPD in New Zealand and the effect of different definitions of airflow obstruction based on post-bronchodilator spirometry is not known. Detailed written questionnaires, full pulmonary function tests (including pre- and post-bronchodilator flow-volume loops) and atopy testing were completed in 749 subjects recruited from a random population sample. The GOLD-defined, age-adjusted prevalence (95% confidence interval) for adults aged >or=40 yrs was 14.2 (11.0-17.0)% compared with an LLN-defined, age-adjusted, post-bronchodilator prevalence in the same group of 9.0 (6.7-11.3)%. The prevalence of chronic obstructive pulmonary disease varied markedly depending on the definition used. Further research using longitudinal rather than cross-sectional data will help decide the preferred approach in chronic obstructive pulmonary disease prevalence surveys.

  5. Numerical analysis of air-flow and temperature field in a passenger car compartment

    NASA Astrophysics Data System (ADS)

    Kamar, Haslinda Mohamed; Kamsah, Nazri; Mohammad Nor, Ahmad Miski

    2012-06-01

    This paper presents a numerical study on the temperature field inside a passenger's compartment of a Proton Wira saloon car using computational fluid dynamics (CFD) method. The main goal is to investigate the effects of different glazing types applied onto the front and rear windscreens of the car on the distribution of air-temperature inside the passenger compartment in the steady-state conditions. The air-flow condition in the passenger's compartment is also investigated. Fluent CFD software was used to develop a three-dimensional symmetrical model of the passenger's compartment. Simplified representations of the driver and one rear passenger were incorporated into the CFD model of the passenger's compartment. Two types of glazing were considered namely clear insulated laminated tint (CIL) with a shading coefficient of 0.78 and green insulated laminate tint (GIL) with a shading coefficient of 0.5. Results of the CFD analysis were compared with those obtained when the windscreens are made up of clear glass having a shading coefficient of 0.86. Results of the CFD analysis show that for a given glazing material, the temperature of the air around the driver is slightly lower than the air around the rear passenger. Also, the use of GIL glazing material on both the front and rear windscreens significantly reduces the air temperature inside the passenger's compartment of the car. This contributes to a better thermal comfort condition to the occupants. Swirling air flow condition occurs in the passenger compartment. The air-flow intensity and velocity are higher along the side wall of the passenger's compartment compared to that along the middle section of the compartment. It was also found that the use of glazing materials on both the front and rear windscreen has no significant effects on the air-flow condition inside the passenger's compartment of the car.

  6. Obstructive renal injury: from fluid mechanics to molecular cell biology.

    PubMed

    Ucero, Alvaro C; Gonçalves, Sara; Benito-Martin, Alberto; Santamaría, Beatriz; Ramos, Adrian M; Berzal, Sergio; Ruiz-Ortega, Marta; Egido, Jesus; Ortiz, Alberto

    2010-04-22

    Urinary tract obstruction is a frequent cause of renal impairment. The physiopathology of obstructive nephropathy has long been viewed as a mere mechanical problem. However, recent advances in cell and systems biology have disclosed a complex physiopathology involving a high number of molecular mediators of injury that lead to cellular processes of apoptotic cell death, cell injury leading to inflammation and resultant fibrosis. Functional studies in animal models of ureteral obstruction using a variety of techniques that include genetically modified animals have disclosed an important role for the renin-angiotensin system, transforming growth factor-β1 (TGF-β1) and other mediators of inflammation in this process. In addition, high throughput techniques such as proteomics and transcriptomics have identified potential biomarkers that may guide clinical decision-making.

  7. Pneumothorax Risk Factors in Smokers with and without Chronic Obstructive Pulmonary Disease

    PubMed Central

    Hobbs, Brian D.; Foreman, Marilyn G.; Bowler, Russell; Jacobson, Francine; Make, Barry J.; Castaldi, Peter J.; San José Estépar, Raúl; Silverman, Edwin K.

    2014-01-01

    Rationale: The demographic, physiological, and computed tomography (CT) features associated with pneumothorax in smokers with and without chronic obstructive pulmonary disease (COPD) are not clearly defined. Objectives: We evaluated the hypothesis that pneumothorax in smokers is associated with male sex, tall and thin stature, airflow obstruction, and increased total and subpleural emphysema. Methods: The study included smokers with and without COPD from the COPDGene Study, with quantitative chest CT analysis. Pleural-based emphysema was assessed on the basis of local histogram measures of emphysema. Pneumothorax history was defined by subject self-report. Measurements and Main Results: Pneumothorax was reported in 286 (3.2%) of 9,062 participants. In all participants, risk of prior pneumothorax was significantly higher in men (odds ratio [OR], 1.55; 95% confidence interval [CI], 1.08–2.22) and non-Hispanic white subjects (OR, 1.90; 95% CI, 1.34–2.69). Risk of prior pneumothorax was associated with increased percent CT emphysema in all participants and participants with COPD (OR, 1.04 for each 1% increase in emphysema; 95% CI, 1.03–1.06). Increased pleural-based emphysema was independently associated with risk of past pneumothorax in all participants (OR, 1.05 for each 1% increase; 95% CI, 1.01–1.10). In smokers with normal spirometry, risk of past pneumothorax was associated with non-Hispanic white race and lifetime smoking intensity (OR, 1.20 for every 10 pack-years; 95% CI, 1.09–1.33). Conclusions: Among smokers, pneumothorax is associated with male sex, non-Hispanic white race, and increased percentage of total and subpleural CT emphysema. Pneumothorax was not independently associated with height or lung function, even in participants with COPD. Clinical trial registered with www.clinicaltrials.gov (NCT00608764). PMID:25295410

  8. Angiotensin-Converting Enzyme Inhibition as an Adjunct to Pulmonary Rehabilitation in Chronic Obstructive Pulmonary Disease

    PubMed Central

    Curtis, Katrina J.; Meyrick, Victoria M.; Mehta, Bhavin; Haji, Gulam S.; Li, Kawah; Montgomery, Hugh; Man, William D.-C.; Polkey, Michael I.

    2016-01-01

    Rationale: Epidemiological studies in older individuals have found an association between the use of angiotensin-converting enzyme (ACE) inhibition (ACE-I) therapy and preserved locomotor muscle mass, strength, and walking speed. ACE-I therapy might therefore have a role in the context of pulmonary rehabilitation (PR). Objectives: To investigate the hypothesis that enalapril, an ACE inhibitor, would augment the improvement in exercise capacity seen during PR. Methods: We performed a double-blind, placebo-controlled, parallel-group randomized controlled trial. Patients with chronic obstructive pulmonary disease, who had at least moderate airflow obstruction and were taking part in PR, were randomized to either 10 weeks of therapy with an ACE inhibitor (10 mg enalapril) or placebo. Measurements and Main Results: The primary outcome measurement was the change in peak power (assessed using cycle ergometry) from baseline. Eighty patients were enrolled, 78 were randomized (age 67 ± 8 years; FEV1 48 ± 21% predicted), and 65 completed the trial (34 on placebo, 31 on the ACE inhibitor). The ACE inhibitor–treated group demonstrated a significant reduction in systolic blood pressure (Δ, −16 mm Hg; 95% confidence interval [CI], −22 to −11) and serum ACE activity (Δ, −18 IU/L; 95% CI, −23 to −12) versus placebo (between-group differences, P < 0.0001). Peak power increased significantly more in the placebo group (placebo Δ, +9 W; 95% CI, 5 to 13 vs. ACE-I Δ, +1 W; 95% CI, −2 to 4; between-group difference, 8 W; 95% CI, 3 to 13; P = 0.001). There was no significant between-group difference in quadriceps strength or health-related quality of life. Conclusions: Use of the ACE inhibitor enalapril, together with a program of PR, in patients without an established indication for ACE-I, reduced the peak work rate response to exercise training in patients with chronic obstructive pulmonary disease. PMID:27248440

  9. Reduced upper obstructions in N3 and increased lower obstructions in REM sleep stage detected with manometry.

    PubMed

    Wirth, Markus; Schramm, Juliane; Bautz, Maximilian; Hofauer, Benedikt; Edenharter, Günther; Ott, Armin; Heiser, Clemens

    2018-01-01

    In obstructive sleep apnea (OSA), airway obstruction occurs at different anatomic levels. The frequency and location of obstructions play a crucial role in the planning of surgical treatment. The aim of this study was to evaluate the pharyngeal obstruction levels in different sleep stages with manometry in OSA patients. In addition, the manometry results were compared with drug-induced sleep endoscopy (DISE). Forty-one patients with OSA received manometry measurements during one night of sleep. All patients were simultaneously evaluated with polysomnography. The frequency of obstructions in different sleep stages was assessed. Twenty patients were additionally studied with DISE. Obstruction levels detected with manometry were compared with DISE. The frequency of upper and to a lesser extent lower obstructions decreased in sleep stage N3. In rapid eye movement (REM) sleep, lower obstructions increased. The overall proportion of upper and lower obstructions detected with manometry corresponded with DISE in 13 of 20 cases. A significant change in the obstruction levels was detected with manometry in N3 and REM sleep. The reduction of both upper and to a lesser extent lower obstructions in N3 suggests more stable airways in slow-wave sleep. Relevant lower obstructions were not detected in DISE compared to manometry in 5 out of 20 examinations. This could be a potential reason for treatment failure of site-specific surgical OSA treatment when only performing DISE preoperatively. Therefore, manometry could be a useful complementary tool in the preoperative evaluation for OSA.

  10. Characterization of Pump-Induced Acoustics in Space Launch System Main Propulsion System Liquid Hydrogen Feedline Using Airflow Test Data

    NASA Technical Reports Server (NTRS)

    Eberhart, C. J.; Snellgrove, L. M.; Zoladz, T. F.

    2015-01-01

    High intensity acoustic edgetones located upstream of the RS-25 Low Pressure Fuel Turbo Pump (LPFTP) were previously observed during Space Launch System (STS) airflow testing of a model Main Propulsion System (MPS) liquid hydrogen (LH2) feedline mated to a modified LPFTP. MPS hardware has been adapted to mitigate the problematic edgetones as part of the Space Launch System (SLS) program. A follow-on airflow test campaign has subjected the adapted hardware to tests mimicking STS-era airflow conditions, and this manuscript describes acoustic environment identification and characterization born from the latest test results. Fluid dynamics responsible for driving discrete excitations were well reproduced using legacy hardware. The modified design was found insensitive to high intensity edgetone-like discretes over the bandwidth of interest to SLS MPS unsteady environments. Rather, the natural acoustics of the test article were observed to respond in a narrowband-random/mixed discrete manner to broadband noise thought generated by the flow field. The intensity of these responses were several orders of magnitude reduced from those driven by edgetones.

  11. Murine model of long-term obstructive jaundice.

    PubMed

    Aoki, Hiroaki; Aoki, Masayo; Yang, Jing; Katsuta, Eriko; Mukhopadhyay, Partha; Ramanathan, Rajesh; Woelfel, Ingrid A; Wang, Xuan; Spiegel, Sarah; Zhou, Huiping; Takabe, Kazuaki

    2016-11-01

    With the recent emergence of conjugated bile acids as signaling molecules in cancer, a murine model of obstructive jaundice by cholestasis with long-term survival is in need. Here, we investigated the characteristics of three murine models of obstructive jaundice. C57BL/6J mice were used for total ligation of the common bile duct (tCL), partial common bile duct ligation (pCL), and ligation of left and median hepatic bile duct with gallbladder removal (LMHL) models. Survival was assessed by Kaplan-Meier method. Fibrotic change was determined by Masson-Trichrome staining and Collagen expression. Overall, 70% (7 of 10) of tCL mice died by day 7, whereas majority 67% (10 of 15) of pCL mice survived with loss of jaundice. A total of 19% (3 of 16) of LMHL mice died; however, jaundice continued beyond day 14, with survival of more than a month. Compensatory enlargement of the right lobe was observed in both pCL and LMHL models. The pCL model demonstrated acute inflammation due to obstructive jaundice 3 d after ligation but jaundice rapidly decreased by day 7. The LHML group developed portal hypertension and severe fibrosis by day 14 in addition to prolonged jaundice. The standard tCL model is too unstable with high mortality for long-term studies. pCL may be an appropriate model for acute inflammation with obstructive jaundice, but long-term survivors are no longer jaundiced. The LHML model was identified to be the most feasible model to study the effect of long-term obstructive jaundice. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. H-1 Nuclear Magnetic Resonance Metabolomics Analysis Identifies Novel Urinary Biomarkers for Lung Function

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MCClay, Joseph L.; Adkins, Daniel E.; Isern, Nancy G.

    2010-06-04

    Chronic obstructive pulmonary disease (COPD), characterized by chronic airflow limitation, is a serious and growing public health concern. The major environmental risk factor for COPD is tobacco smoking, but the biological mechanisms underlying COPD are not well understood. In this study, we used proton nuclear magnetic resonance (1H-NMR) spectroscopy to identify and quantify metabolites associated with lung function in COPD. Plasma and urine were collected from 197 adults with COPD and from 195 adults without COPD. Samples were assayed using a 600 MHz NMR spectrometer, and the resulting spectra were analyzed against quantitative spirometric measures of lung function. After correctingmore » for false discoveries and adjusting for covariates (sex, age, smoking) several spectral regions in urine were found to be significantly associated with baseline lung function. These regions correspond to the metabolites trigonelline, hippurate and formate. Concentrations of each metabolite, standardized to urinary creatinine, were associated with baseline lung function (minimum p-value = 0.0002 for trigonelline). No significant associations were found with plasma metabolites. Two of the three urinary metabolites positively associated with baseline lung function, i.e. hippurate and formate, are often related to gut microflora. This suggests that the microbiome composition is variable between individuals with different lung function. Alternatively, the nature and origins of all three associated metabolites may reflect lifestyle differences affecting overall health. Our results will require replication and validation, but demonstrate the utility of NMR metabolomics as a screening tool for identifying novel biomarkers of lung disease or disease risk.« less

  13. Field measurements of mean and turbulent airflow over a barchan sand dune

    NASA Astrophysics Data System (ADS)

    Weaver, Corinne M.; Wiggs, Giles F. S.

    2011-05-01

    Advances in our knowledge of the aeolian processes governing sand dune dynamics have been restricted by a reliance on measures of time-averaged airflow, such as shear velocity ( u*). It has become clear that such measures are incapable of explaining the complete dynamics of sediment transport across dune surfaces. Past evidence from wind tunnel and modelling studies has suggested that in some regions on a dune's surface the sediment transport might be better explained through investigations of the turbulent nature of the airflow. However, to date there have been no field studies providing data on the turbulent characteristics of the airflow around dunes with which to support or refute such hypotheses. The field investigation presented here provides mean and turbulent airflow measurements across the centre-line of a barchan sand dune in Namibia. Data were collected using arrays of sonic anemometers and were compared with sand flux data measured using wedge-shaped traps. Results support previously published data derived from wind tunnels and numerical models. The decline in mean wind velocity at the upwind toe of the dune is shown to coincide with a rise in turbulence, whilst mean velocity acceleration on the upper slope corresponds with a general decline in measured turbulence. Analysis of the components of Reynold shear stress ( -u'¯w'¯) and normal stresses ( u¯ and w2 ¯) supports the notion that the development of flow turbulence along the dune centre-line is likely to be associated with the interplay between streamline curvature and mean flow deceleration/acceleration. It is suggested that, due to the nature of its calculation, turbulence intensity is a measure of less practical use than direct assessments of the individual components of Reynolds stress, particularly the instantaneous horizontal streamwise component ( u2 ¯) and shear stress ( -uw¯). Whilst, increases in Reynolds shear stress and the horizontal streamwise component of stress in the toe

  14. Nasal obstruction and human communication.

    PubMed

    Malinoff, R; Moreno, C

    1989-04-01

    Nasal obstruction may cause a variety of communication disorders, particularly in children. The effects of nasal obstruction on hearing, speech, language, and voice are examined. Methods for assessing the effects of nasal obstruction are delineated, and recommendations for therapeutic interventions are described.

  15. Exercise-Induced Changes in Exhaled NO Differentiates Asthma With or Without Fixed Airway Obstruction From COPD With Dynamic Hyperinflation.

    PubMed

    Huang, Shu-Yi; Chou, Pai-Chien; Wang, Tsai-Yu; Lo, Yu-Lun; Joa, Wen-Ching; Chen, Li-Fei; Sheng, Te-Fang; Chung, Kian Fan; Wang, Chun-Hua; Kuo, Han-Pin

    2016-04-01

    Asthmatic patients with fixed airway obstruction (FAO) and patients with chronic obstructive pulmonary disease (COPD) share similarities in terms of irreversible pulmonary function impairment. Exhaled nitric oxide (eNO) has been documented as a marker of airway inflammation in asthma, but not in COPD. To examine whether the basal eNO level and the change after exercise may differentiate asthmatics with FAO from COPD, 27 normal subjects, 60 stable asthmatics, and 62 stable COPD patients were studied. Asthmatics with FAO (n = 29) were defined as showing a postbronchodilator FEV1/forced vital capacity (FVC) ≤70% and FEV1 less than 80% predicted after inhaled salbutamol (400 μg). COPD with dynamic hyperinflation (n = 31) was defined as a decrease in inspiratory capacity (ΔIC%) after a 6 minute walk test (6MWT). Basal levels of eNO were significantly higher in asthmatics and COPD patients compared to normal subjects. The changes in eNO after 6MWT were negatively correlated with the percent change in IC (r = -0.380, n = 29, P = 0.042) in asthmatics with FAO. Their levels of basal eNO correlated with the maximum mid-expiratory flow (MMEF % predicted) before and after 6MWT. In COPD patients with air-trapping, the percent change of eNO was positively correlated to ΔIC% (rs = 0.404, n = 31, P = 0.024). We conclude that asthma with FAO may represent residual inflammation in the airways, while dynamic hyperinflation in COPD may retain NO in the distal airspace. eNO changes after 6MWT may differentiate the subgroups of asthma or COPD patients and will help toward delivery of individualized therapy for airflow obstruction.

  16. Exercise-Induced Changes in Exhaled NO Differentiates Asthma With or Without Fixed Airway Obstruction From COPD With Dynamic Hyperinflation

    PubMed Central

    Huang, Shu-Yi; Chou, Pai-Chien; Wang, Tsai-Yu; Lo, Yu-Lun; Joa, Wen-Ching; Chen, Li-Fei; Sheng, Te-Fang; Chung, Kian Fan; Wang, Chun-Hua; Kuo, Han-Pin

    2016-01-01

    Abstract Asthmatic patients with fixed airway obstruction (FAO) and patients with chronic obstructive pulmonary disease (COPD) share similarities in terms of irreversible pulmonary function impairment. Exhaled nitric oxide (eNO) has been documented as a marker of airway inflammation in asthma, but not in COPD. To examine whether the basal eNO level and the change after exercise may differentiate asthmatics with FAO from COPD, 27 normal subjects, 60 stable asthmatics, and 62 stable COPD patients were studied. Asthmatics with FAO (n = 29) were defined as showing a postbronchodilator FEV1/forced vital capacity (FVC) ≤70% and FEV1 less than 80% predicted after inhaled salbutamol (400 μg). COPD with dynamic hyperinflation (n = 31) was defined as a decrease in inspiratory capacity (ΔIC%) after a 6 minute walk test (6MWT). Basal levels of eNO were significantly higher in asthmatics and COPD patients compared to normal subjects. The changes in eNO after 6MWT were negatively correlated with the percent change in IC (r = −0.380, n = 29, P = 0.042) in asthmatics with FAO. Their levels of basal eNO correlated with the maximum mid-expiratory flow (MMEF % predicted) before and after 6MWT. In COPD patients with air-trapping, the percent change of eNO was positively correlated to ΔIC% (rs = 0.404, n = 31, P = 0.024). We conclude that asthma with FAO may represent residual inflammation in the airways, while dynamic hyperinflation in COPD may retain NO in the distal airspace. eNO changes after 6MWT may differentiate the subgroups of asthma or COPD patients and will help toward delivery of individualized therapy for airflow obstruction. PMID:27082615

  17. Primary obstructive megaureter.

    PubMed

    Sripathi, V; King, P A; Thomson, M R; Bogle, M S

    1991-07-01

    Twenty-three children with primary obstructive megaureters presented between 1978 and 1988 to the Princess Margaret Hospital for Children in Perth. Twenty-eight ureters were treated. Urinary infections were the presenting feature in 14 children. The obstructive segment was transvesically excised. Histopathologic examination of the distal, intramural ureter showed fibromuscular disarray with a relative increase in fibrous tissue and reduction of musculature in all specimens. Twenty-two ureters were tapered by excision and all 28 were reimplanted using an antireflux technique. Seventeen children were followed for an average of 3 years. Seven children showed renal growth, reduction in ureteric size by greater than 2 cm, improvement in glomerular filtration rate by more than 10%, no obstruction on reflux, and no infections in postoperative period. Four children showed all the above but suffered one or more infections after the operation. Of the remaining 6 children, 3 had postoperative obstruction and 3 had vesicoureteric reflux.

  18. Respiratory kinematic and airflow differences between reflex and voluntary cough in healthy young adults

    PubMed Central

    Brandimore, Alexandra E.; Troche, Michelle S.; Huber, Jessica E.; Hegland, Karen W.

    2015-01-01

    Background: Cough is a defensive behavior that can be initiated in response to a stimulus in the airway (reflexively), or on command (voluntarily). There is evidence to suggest that physiological differences exist between reflex and voluntary cough; however, the output (mechanistic and airflow) differences between the cough types are not fully understood. Therefore, the aims of this study were to determine the lung volume, respiratory kinematic, and airflow differences between reflex and voluntary cough in healthy young adults. Methods: Twenty-five participants (14 female; 18–29 years) were recruited for this study. Participants were evaluated using respiratory inductance plethysmography calibrated with spirometry. Experimental procedures included: (1) respiratory calibration, (2) three voluntary sequential cough trials, and (3) three reflex cough trials induced with 200 μM capsaicin. Results: Lung volume initiation (LVI; p = 0.003) and lung volume excursion (LVE; p < 0.001) were significantly greater for voluntary cough compared to reflex cough. The rib cage and abdomen significantly influenced LVI for voluntary cough (p < 0.001); however, only the rib cage significantly impacted LVI for reflex cough (p < 0.001). LVI significantly influenced peak expiratory flow rate (PEFR) for voluntary cough (p = 0.029), but not reflex cough (p = 0.610). Discussion: Production of a reflex cough results in significant mechanistic and airflow differences compared to voluntary cough. These findings suggest that detection of a tussigenic stimulus modifies motor aspects of the reflex cough behavior. Further understanding of the differences between reflex and voluntary cough in older adults and in persons with dystussia (cough dysfunction) will be essential to facilitate the development of successful cough treatment paradigms. PMID:26500560

  19. The effect of airflow on thermographically determined temperature of the distal forelimb of the horse.

    PubMed

    Westermann, S; Stanek, C; Schramel, J P; Ion, A; Buchner, H H F

    2013-09-01

    Current literature suggests that thermographic imaging of horses should be performed in a draught-free room. However, studies on the effect of airflow on determined temperature have not been published. To investigate effects of airflow on thermographically determined temperature of horses' forelimbs; to assess the relationship of wind velocity, rectal temperature, ambient temperature and humidity. Thermographic images were obtained for the forelimbs of 6 horses in a draught-free room. Three replicates (R) with defined wind velocities (R1, 0.5-1.0 m/s; R2, 1.3-2.6 m/s; and R3, 3.0-4.0 m/s) were conducted. Each replicate consisted of a baseline image, a 15 min phase with the wind on and a 15 min phase with the wind off. We exposed only the right leg to airflow and determined the temperature by thermography with the wind on and wind off. Temperature differences between baseline and wind on, between wind on and wind off and between different wind velocities were analysed by a general linear model, Student's paired t test and ANOVA. After the onset of wind, the temperature on the right forelimb decreased within 1-3 min (by approximately 0.6°C at R1, 1.5°C at R2 and 2.1°C at R3). With the wind off, the temperature increased within 3 min (by approximately 1.2°C at R1, 1.7°C at R2 and 2.1°C at R3). With increasing wind velocity, the temperature differences between baseline and wind on and between wind on and wind off increased significantly. Barely noticeable wind velocities caused a decrease in thermographically determined temperatures of the forelimbs of the horse. Further research is required to assess the influence of airflow on other parts of the body and at different ambient temperatures, as well as the effect on horses with inflammatory lesions, especially of the distal limbs. It is essential for practitioners to perform thermography on horses in a draught-free environment in order to avoid false-positive or -negative diagnoses. © 2012 EVJ Ltd.

  20. An examination of elicitation method on fundamental frequency and repeatability of average airflow measures in children age 4:0-5:11 years.

    PubMed

    Brehm, Susan Baker; Weinrich, Barbara D; Sprouse, Dana C; May, Shelley K; Hughes, Michael R

    2012-11-01

    The purpose of this study was to determine the effect of task type on fundamental frequency (F(0)) and the short-term repeatability of average airflow values in preschool/kindergarten-age children. Prospective, experimental. Thirty healthy children (age 4.0-5.11 years) were included in this study. Participants completed three tasks (sustained vowel, counting, and storytelling) used to elicit measurements of F(0). With a 10-minute interval, participants also completed two trials of sustained /a/ at a comfortable pitch and loudness level for the measurement of average airflow rate. F(0) and intensity of the vowel production were recorded for both trials. A repeated measures analysis of variance revealed a significant main effect for task type elicitation on F(0) values (P=0.0003). A significant difference between elicitation tasks for F(0) was observed in the comparison of the counting and storytelling task (P<0.0001). A paired t test revealed no significant difference in average airflow rate across two trials (P=0.872). The change in F(0) and intensity was measured across the trials, and separate analyses of covariance revealed that these changes did not significantly influence average airflow values, (P=0.809) and (P=0.365), respectively. The results of this study demonstrated that F(0) may be influenced by task type in young children. Average airflow values appear to be stable over a short time period. This information is important in determining methods of evaluation and the reliability of instrumental measures in young children with voice disorders. Copyright © 2012 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  1. Predictors of mortality in patients with emphysema and severe airflow obstruction.

    PubMed

    Martinez, Fernando J; Foster, Gregory; Curtis, Jeffrey L; Criner, Gerard; Weinmann, Gail; Fishman, Alfred; DeCamp, Malcolm M; Benditt, Joshua; Sciurba, Frank; Make, Barry; Mohsenifar, Zab; Diaz, Philip; Hoffman, Eric; Wise, Robert

    2006-06-15

    Limited data exist describing risk factors for mortality in patients having predominantly emphysema. A total of 609 patients with severe emphysema (ages 40-83 yr; 64.2% male) randomized to the medical therapy arm of the National Emphysema Treatment Trial formed the study group. Cox proportional hazards regression analysis was used to investigate risk factors for all-cause mortality. Risk factors examined included demographics, body mass index, physiologic data, quality of life, dyspnea, oxygen utilization, hemoglobin, smoking history, quantitative emphysema markers on computed tomography, and a modification of a recently described multifunctional index (modified BODE). Overall, high mortality was seen in this cohort (12.7 deaths per 100 person-years; 292 total deaths). In multivariate analyses, increasing age (p=0.001), oxygen utilization (p=0.04), lower total lung capacity % predicted (p=0.05), higher residual volume % predicted (p=0.04), lower maximal cardiopulmonary exercise testing workload (p=0.002), greater proportion of emphysema in the lower lung zone versus the upper lung zone (p=0.005), and lower upper-to-lower-lung perfusion ratio (p=0.007), and modified BODE (p=0.02) were predictive of mortality. FEV1 was a significant predictor of mortality in univariate analysis (p=0.005), but not in multivariate analysis (p=0.21). Although patients with advanced emphysema experience significant mortality, subgroups based on age, oxygen utilization, physiologic measures, exercise capacity, and emphysema distribution identify those at increased risk of death.

  2. Advanced Ignition in Supersonic Airflow by Tunable Plasma System

    NASA Astrophysics Data System (ADS)

    Firsov, A. A.; Dolgov, E. V.; Leonov, S. B.; Yarantsev, D. A.

    2017-10-01

    The plasma-based technique was studied for ignition and flameholding in a supersonic airflow in different laboratories for a long time. It was shown that flameholding of gaseous and liquid hydrocarbon fuel is feasible by means of surface DC discharge without employing mechanical flameholders in a supersonic combustion chamber. However, a high power consumption may limit application of this method in a real apparatus. This experimental and computational work explores a distributed plasma system, which allows reducing the total energy consumption and extending the life cycle of the electrode system. Due to the circuit flexibility, this approach may be potentially enriched with feedbacks for design of a close loop control system.

  3. A Numerical Model of Viscoelastic Layer Entrainment by Airflow in Cough

    NASA Astrophysics Data System (ADS)

    Mitran, Sorin M.

    2008-07-01

    Coughing is an alternative mode of ensuring mucus clearance in the lung when normal cilia induced flow breaks down. A numerical model of this process is presented with the following aspects. (1) A portion of the airway comprising the first three bronchus generations is modeled as radially reinforced elastic tubes. Elasticity equations are solved to predict airway deformation under effect of airway pressure. (2) The compressible, turbulent flow induced by rapid lung contraction is modeled by direct numerical simulation for Reynolds numbers in the range 5,000-10,000 and by Large Eddy Simulation for Reynolds numbers in the range 5,000-40,000. (3) A two-layer model of the airway surface liquid (ASL) covering the airway epithelial layer is used. The periciliary liquid (PCL) in direct contact with the epithelial layer is considered to be a Newtonian fluid. Forces modeling cilia beating can act upon this layer. The mucus layer between the PCL and the interior airflow is modeled as an Oldroyd-B fluid. The overall computation is a fluid-structure interaction simulation that tracks changes in ASL thickness and airway diameters that result from impulsive airflow boundary conditions imposed at bronchi ends. In particular, the amount of mucus that is evacuated from the system is computed as a function of cough intensity and mucus rheological properties.

  4. Evaluation of two techniques of partial urethral obstruction in the male rat model of bladder outlet obstruction.

    PubMed

    Melman, Arnold; Tar, Moses; Boczko, Judd; Christ, George; Leung, Albert C; Zhao, Weixin; Russell, Robert G

    2005-11-01

    To perform a comparison to determine which of two methods of partial urethral ligation produces the most consistent outcome and fewest side effects. Such a study has not been previously reported. Partial urethral ligation is a means of causing reproducible bladder outlet obstruction. In the male rat model, partial urethral obstruction can be performed either by perineal incision and bulbous urethral ligation or retropubic incision and midprostatic obstruction. Fifteen male Sprague-Dawley rats were studied. Five were selected for bulbous urethral obstruction through a perineal incision, five for midprostatic obstruction using a retropubic approach, and five for a sham operation through a perineal incision. The operative time was shorter and morbidity lower with the perineal approach compared with the retropubic approach. Inflammation or infection, or both, were seen in the prostate, bladder, proximal urethra, ureters, and kidneys in the rats in which a midprostatic obstruction was performed. The proximal urethra and prostate were mildly inflamed in those rats that underwent bulbous obstruction. Sham-operated rats exhibited mild prostatitis only. The perineal approach to the bulbous urethra is the method of choice for creating a partial urethral obstruction model of bladder outlet obstruction in the male rat.

  5. Early Detection of Chronic Obstructive Pulmonary Disease in Primary Care.

    PubMed

    Kobayashi, Seiichi; Hanagama, Masakazu; Yanai, Masaru

    2017-12-01

    Objective To evaluate the effectiveness of an early detection program for chronic obstructive pulmonary disease (COPD) in a primary care setting in Japan. Methods Participants of ≥40 years of age who regularly visited a general practitioner's clinic due to chronic disease were asked to complete a COPD screening questionnaire (COPD Population Screener; COPD-PS) and undergo simplified spirometry using a handheld spirometric device. Patients who showed possible COPD were referred to a respiratory specialist and underwent a detailed examination that included spirometry and chest radiography. Results A total of 111 patients with possible COPD were referred for close examination. Among these patients, 27 patients were newly diagnosed with COPD. The patients with COPD were older, had lower BMI values, and had a longer smoking history in comparison to non-COPD patients. COPD patients also had more comorbid conditions. A diagnosis of COPD was significantly associated with a high COPD-PS score (p<0.001) and the detection of possible airflow limitation evaluated by the handheld spirometric device (p<0.01). An ROC curve analysis demonstrated that 5 points was the best COPD-PS cut-off value for the diagnosis of COPD. The combination of both tools showed 40.7% of sensitivity and 96.4% of specificity. Conclusion The use of the COPD-PS plus a handheld spirometric device could facilitate the early detection of undiagnosed COPD in primary care.

  6. Sepsis and acute respiratory distress syndrome requiring extracorporeal life support in an adolescent with mild cystic fibrosis.

    PubMed

    Faricy, Lauren Elizabeth; Church, Gwynne

    2017-01-01

    Outcomes for invasive mechanical ventilation and extracorporeal membrane oxygenation (ECMO) to treat acute respiratory failure in patients with mild cystic fibrosis (CF) lung disease are not known. We present a case of the successful use of ECMO to treat acute respiratory failure secondary to staphylococcal sepsis in an adolescent CF patient with previously normal lung function. Her post-ECMO course was notable for severe airflow obstruction, hypoxemia, deconditioning, and growth failure. She had significantly improved at six months follow-up, though she continued to have moderate airflow obstruction on pulmonary function testing. This case illustrates that ECMO and prolonged intubation can prolong life in CF patients with mild lung disease who present with potentially reversible acute respiratory failure, though they are associated with significant morbidity.

  7. Correlation of soft palate length with velum obstruction and severity of obstructive sleep apnea syndrome.

    PubMed

    Lim, Ju-Shin; Lee, Jae Woo; Han, Chun; Kwon, Jang-Woo

    2018-06-01

    Our aim in this study was to analyze whether soft palate length and velum obstruction during sleep are correlated and to determine the effects of related parameters on obstructive sleep apnea syndrome (OSAS) severity. We used computed tomography to measure soft palate length and drug-induced sleep endoscopy (DISE) to evaluate velum obstruction severity. Patients also underwent polysomnography (PSG) for evaluation of OSAS severity. A retrospective cohort of 67 patients with OSAS treated between May 1st, 2013 and July 31st, 2016 was analyzed. Each patient underwent DISE, PSG, and computed tomography. Using DISE, velum obstruction was categorized by the VOTE classification method. Using computed tomography, soft palate length was measured as the length of the posterior nasal spine to the uvula. Correlations of velum obstruction in DISE and PSG parameters (obstructive apnea, hypopnea, apnea hypopnea index (AHI), respiratory effort related arousal (RERA), respiratory disturbance index (RDI), baseline SaO 2 , and minimum SaO 2 ) with soft palate length were also analyzed. Among the 67 patients, the average PNS-U length was 39.90±4.19mm. Length was significantly different by age but not by other demographic characteristics such as sex, past history, or BMI. DISE revealed a statistically significant difference of velum obstruction degree; the cutoff value for PNS-U was 39.47mm. The PSG results, obstructive apnea, AHI, RDI, baseline SaO 2 , and minimum SaO 2 were correlated with PNS-U length, while other results such as hypopnea and RERA showed no correlation. Analysis of soft palate length showed that increased PNS-U length was associated with higher rates of obstructive apnea, AHI, and RDI as assessed by PSG. In contrast, lower baseline SaO 2 and minimum SaO 2 values were seen by PSG; more severe velum obstruction was seen by DISE. We propose that when a soft palate is suspected in OSAS, computed tomography measurement of soft palate length is a valid method for

  8. Nasal Involvement in Obstructive Sleep Apnea Syndrome

    PubMed Central

    Michels, Daniel de Sousa; Rodrigues, Amanda da Mota Silveira; Nakanishi, Márcio; Sampaio, André Luiz Lopes; Venosa, Alessandra Ramos

    2014-01-01

    Numerous studies have reported an association between nasal obstruction and obstructive sleep apnea syndrome (OSAS), but the precise nature of this relationship remains to be clarified. This paper aimed to summarize data and theories on the role of the nose in the pathophysiology of sleep apnea as well as to discuss the benefits of surgical and medical nasal treatments. A number of pathophysiological mechanisms can potentially explain the role of nasal pathology in OSAS. These include the Starling resistor model, the unstable oral airway, the nasal ventilatory reflex, and the role of nitric oxide (NO). Pharmacological treatment presents some beneficial effects on the frequency of respiratory events and sleep architecture. Nonetheless, objective data assessing snoring and daytime sleepiness are still necessary. Nasal surgery can improve the quality of life and snoring in a select group of patients with mild OSAS and septal deviation but is not an effective treatment for OSA as such. Despite the conflicting results in the literature, it is important that patients who are not perfectly adapted to CPAP are evaluated in detail, in order to identify whether there are obstructive factors that could be surgically corrected. PMID:25548569

  9. The epidemiology of adult obstructive sleep apnea.

    PubMed

    Punjabi, Naresh M

    2008-02-15

    Obstructive sleep apnea is a chronic condition characterized by frequent episodes of upper airway collapse during sleep. Its effect on nocturnal sleep quality and ensuing daytime fatigue and sleepiness are widely acknowledged. Increasingly, obstructive sleep apnea is also being recognized as an independent risk factor for several clinical consequences, including systemic hypertension, cardiovascular disease, stroke, and abnormal glucose metabolism. Estimates of disease prevalence are in the range of 3% to 7%, with certain subgroups of the population bearing higher risk. Factors that increase vulnerability for the disorder include age, male sex, obesity, family history, menopause, craniofacial abnormalities, and certain health behaviors such as cigarette smoking and alcohol use. Despite the numerous advancements in our understanding of the pathogenesis and clinical consequences of the disorder, a majority of those affected remain undiagnosed. Simple queries of the patient or bed-partner for the symptoms and signs of the disorder, namely, loud snoring, observed apneas, and daytime sleepiness, would help identify those in need of further diagnostic evaluation. The primary objective of this article is to review some of the epidemiologic aspects of obstructive sleep apnea in adults.

  10. Mechanical Design of a Performance Test Rig for the Turbine Air-Flow Task (TAFT)

    NASA Technical Reports Server (NTRS)

    Xenofos, George; Forbes, John; Farrow, John; Williams, Robert; Tyler, Tom; Sargent, Scott; Moharos, Jozsef

    2003-01-01

    To support development of the Boeing-Rocketdyne RS84 rocket engine, a fill-flow, reaction turbine geometry was integrated into the NASA-MSFC turbine air-flow test facility. A mechanical design was generated which minimized the amount of new hardware while incorporating all test and instrUmentation requirements. This paper provides details of the mechanical design for this Turbine Air-Flow Task (TAFT) test rig. The mechanical design process utilized for this task included the following basic stages: Conceptual Design. Preliminary Design. Detailed Design. Baseline of Design (including Configuration Control and Drawing Revision). Fabrication. Assembly. During the design process, many lessons were learned that should benefit future test rig design projects. Of primary importance are well-defined requirements early in the design process, a thorough detailed design package, and effective communication with both the customer and the fabrication contractors. The test rig provided steady and unsteady pressure data necessary to validate the computational fluid dynamics (CFD) code. The rig also helped characterize the turbine blade loading conditions. Test and CFD analysis results are to be presented in another JANNAF paper.

  11. Collective odor source estimation and search in time-variant airflow environments using mobile robots.

    PubMed

    Meng, Qing-Hao; Yang, Wei-Xing; Wang, Yang; Zeng, Ming

    2011-01-01

    This paper addresses the collective odor source localization (OSL) problem in a time-varying airflow environment using mobile robots. A novel OSL methodology which combines odor-source probability estimation and multiple robots' search is proposed. The estimation phase consists of two steps: firstly, the separate probability-distribution map of odor source is estimated via Bayesian rules and fuzzy inference based on a single robot's detection events; secondly, the separate maps estimated by different robots at different times are fused into a combined map by way of distance based superposition. The multi-robot search behaviors are coordinated via a particle swarm optimization algorithm, where the estimated odor-source probability distribution is used to express the fitness functions. In the process of OSL, the estimation phase provides the prior knowledge for the searching while the searching verifies the estimation results, and both phases are implemented iteratively. The results of simulations for large-scale advection-diffusion plume environments and experiments using real robots in an indoor airflow environment validate the feasibility and robustness of the proposed OSL method.

  12. Collective Odor Source Estimation and Search in Time-Variant Airflow Environments Using Mobile Robots

    PubMed Central

    Meng, Qing-Hao; Yang, Wei-Xing; Wang, Yang; Zeng, Ming

    2011-01-01

    This paper addresses the collective odor source localization (OSL) problem in a time-varying airflow environment using mobile robots. A novel OSL methodology which combines odor-source probability estimation and multiple robots’ search is proposed. The estimation phase consists of two steps: firstly, the separate probability-distribution map of odor source is estimated via Bayesian rules and fuzzy inference based on a single robot’s detection events; secondly, the separate maps estimated by different robots at different times are fused into a combined map by way of distance based superposition. The multi-robot search behaviors are coordinated via a particle swarm optimization algorithm, where the estimated odor-source probability distribution is used to express the fitness functions. In the process of OSL, the estimation phase provides the prior knowledge for the searching while the searching verifies the estimation results, and both phases are implemented iteratively. The results of simulations for large-scale advection–diffusion plume environments and experiments using real robots in an indoor airflow environment validate the feasibility and robustness of the proposed OSL method. PMID:22346650

  13. Reconstructing atmospheric circulation over southern New Zealand: Establishment of modern westerly airflow 5500 years ago and implications for Southern Hemisphere Holocene climate change

    NASA Astrophysics Data System (ADS)

    Turney, C. S. M.; Wilmshurst, J. M.; Jones, R. T.; Wood, J. R.; Palmer, J. G.; Hogg, A. G.; Fenwick, P.; Crowley, S. F.; Privat, K.; Thomas, Z.

    2017-03-01

    Late-twentieth century changes in the intensity and migration of Southern Hemisphere westerly winds have been implicated in spatially complex variability in atmospheric and ocean circulation, and ice-sheet dynamics, across the mid- to high-latitudes. A major uncertainty, however, is whether present day hemispheric-wide symmetrical airflow is representative of past behaviour. Here we report a multi-proxy study from Stewart Island and southern Fiordland, New Zealand (46-47°S) reconstructing Holocene changes at the northern limit of westerly airflow. Increased minerogenic input and a pronounced shift in cool-loving vegetation around 5500 years ago is consistent with the establishment of westerly airflow at this latitude in the southwest Pacific. In marked contrast, stronger winds are reported further south over the subantarctic Auckland (50°S) and Campbell (52°S) Islands from 8000 years ago. Intriguingly, reconstructions from the east Pacific suggest a weakening of core westerly airflow after 8500 years ago, but an expansion along the northern limits sometime after 5500 years ago. Our results suggest similar atmospheric circulation changes have been experienced in the Pacific since 5500 years ago, but indicate an expanded network of sites is needed to comprehensively test the driver(s) and impact(s) of Holocene mid-latitude westerly winds across the Southern Hemisphere.

  14. Nutritional status and patient characteristics for hospitalised older patients with chronic obstructive pulmonary disease.

    PubMed

    Odencrants, Sigrid; Ehnfors, Margareta; Ehrenberg, Anna

    2008-07-01

    The aim of the study was to describe and compare nutritional status and social and medical characteristics among older patients with chronic obstructive pulmonary disease admitted to an acute care hospital ward for respiratory medicine. Chronic obstructive pulmonary disease is a condition associated with risk of developing malnutrition. A body mass index <20 is predictive of hospitalisation for acute exacerbations of chronic obstructive pulmonary disease. Knowledge about patient characteristics is crucial for the identification of malnourished patients and the development of nursing care for these patients. Quantitative descriptive study. Thirty-three hospitalised women and 17 men with a mean age of 75.7 years (SD 6.9) were consecutively included. A very severe case of chronic obstructive pulmonary disease was indicated in 28 out of 39 patients who underwent a lung function test. Data were collected with measurement of nutritional status using Mini Nutritional Assessment, anthropometry and lung function. Nearly half of the patients (48%) were identified as malnourished, an equal part as at risk for malnutrition and two patients as well nourished. The mean Mini Nutritional Assessment score of 17.2 (SD 3.99) for all patients was near the Mini Nutritional Assessment cut-off score (i.e. 17) for malnutrition. Patients identified as malnourished had a mean body mass index of 18.9 and those at risk for malnutrition had a mean of 23.4. It was more common for those identified as malnourished to live singly, to not live in own property and to be dependent on daily community service. Seven patients identified as malnourished died during the data collection period. This study provides important knowledge about further risks of impaired nutritional status among older patients with chronic obstructive pulmonary disease. This knowledge can provide registered nurses with the necessary knowledge to make them aware of certain patients needing particular kinds of attention.

  15. Long Noncoding RNAs and mRNA Regulation in Peripheral Blood Mononuclear Cells of Patients with Chronic Obstructive Pulmonary Disease

    PubMed Central

    Wang, Weijia; Xu, Dan

    2018-01-01

    Background Inflammation plays a pivotal role in the pathogenesis of chronic obstructive pulmonary disease (COPD). We evaluated the lncRNA and mRNA expression profile of peripheral blood mononuclear cells (PBMCs) from healthy nonsmokers, smokers without airflow limitation, and COPD patients. Methods lncRNA and mRNA profiling of PBMCs from 17 smokers and 14 COPD subjects was detected by high-throughput microarray. The expression of dysregulated lncRNAs was validated by qPCR. The lncRNA targets in dysregulated mRNAs were predicted and the GO enrichment was analyzed. The regulatory role of lncRNA ENST00000502883.1 on CXCL16 expression and consequently the effect on PBMC recruitment were investigated by siRNA knockdown and chemotaxis analysis. Results We identified 158 differentially expressed lncRNAs in PBMCs from COPD subjects compared with smokers. The dysregulated expression of 5 selected lncRNAs NR_026891.1 (FLJ10038), ENST00000502883.1 (RP11-499E18.1), HIT000648516, XR_429541.1, and ENST00000597550.1 (CTD-2245F17.3), was validated. The GO enrichment showed that leukocyte migration, immune response, and apoptosis are the main enriched processes that previously reported to be involved in the pathogenesis of COPD. The regulatory role of ENST00000502883.1 on CXCL16 expression and consequently the effect on PBMC recruitment was confirmed. Conclusion This study may provide clues for further studies targeting lncRNAs to control inflammation in COPD. PMID:29725270

  16. The Patient Burden of Bladder Outlet Obstruction after Prostate Cancer Treatment.

    PubMed

    Liberman, Daniel; Jarosek, Stephanie; Virnig, Beth A; Chu, Haitao; Elliott, Sean P

    2016-05-01

    Bladder outlet obstruction after prostate cancer therapy imposes a significant burden on health and quality of life in men. Our objective was to describe the burden of bladder outlet obstruction after prostate cancer therapy by detailing the type of procedures performed and how often those procedures were repeated in men with recurrent bladder outlet obstruction. Using SEER (Surveillance, Epidemiology and End Results)-Medicare linked data from 1992 to 2007 with followup through 2009 we identified 12,676 men who underwent at least 1 bladder outlet obstruction procedure after prostate cancer therapy, including external beam radiotherapy in 3,994, brachytherapy in 1,485, brachytherapy plus external beam radiotherapy in 1,847, radical prostatectomy in 4,736, radical prostatectomy plus external beam radiotherapy in 369 and cryotherapy in 245. Histogram, incidence rates and Cox proportional hazards models with repeat events analysis were done to describe the burden of repeat bladder outlet obstruction treatments stratified by prostate cancer therapy type. We describe the type of bladder outlet obstruction surgery grouped by level of invasiveness. At a median followup of 8.8 years 44.6% of men underwent 2 or more bladder outlet obstruction procedures. Compared to men who underwent radical prostatectomy those treated with brachytherapy and brachytherapy plus external beam radiotherapy were at increased adjusted risk for repeat bladder outlet obstruction treatment (HR 1.2 and 1.32, respectively, each p <0.05). After stricture incision the men treated with radical prostatectomy or radical prostatectomy plus external beam radiotherapy were most likely to undergo dilation at a rate of 34.7% to 35.0%. Stricture resection/ablation was more common after brachytherapy, external beam radiotherapy or brachytherapy plus external beam radiotherapy at a rate of 28.9% to 41.2%. Almost half of the men with bladder outlet obstruction after prostate cancer therapy undergo more than 1

  17. Potential radiological impact of tornadoes on the safety of Nuclear Fuel Services' West Valley Fuel Reprocessing Plant. Volume I. Tornado effects on head-end cell airflow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holloway, L.J.; Andrae, R.W.

    1981-09-01

    This report describes results of a parametric study of the impacts of a tornado-generated depressurization on airflow in the contaminated process cells within the presently inoperative Nuclear Fuel Services fuel reprocessing facility near West Valley, NY. The study involved the following tasks: (1) mathematical modeling of installed ventilation and abnormal exhaust pathways from the cells and prediction of tornado-induced airflows in these pathways; (2) mathematical modeling of individual cell flow characteristics and prediction of in-cell velocities induced by flows from step 1; and (3) evaluation of the results of steps 1 and 2 to determine whether any of the pathwaysmore » investigated have the potential for releasing quantities of radioactively contaminated air from the main process cells. The study has concluded that in the event of a tornado strike, certain pathways from the cells have the potential to release radioactive materials of the atmosphere. Determination of the quantities of radioactive material released from the cells through pathways identified in step 3 is presented in Part II of this report.« less

  18. Oral appliances and functional orthopaedic appliances for obstructive sleep apnoea in children.

    PubMed

    Carvalho, Fernando R; Lentini-Oliveira, Débora A; Prado, Lucila Bf; Prado, Gilmar F; Carvalho, Luciane Bc

    2016-10-05

    Apnoea is a breathing disorder marked by the absence of airflow at the nose or mouth. In children, risk factors include adenotonsillar hypertrophy, obesity, neuromuscular disorders and craniofacial anomalies. The most common treatment for obstructive sleep apnoea syndrome (OSAS) in childhood is adeno-tonsillectomy. This approach is limited by its surgical risks, mostly in children with comorbidities and, in some patients, by recurrence that can be associated with craniofacial problems. Oral appliances and functional orthopaedic appliances have been used for patients who have OSAS and craniofacial anomalies because they hold the lower jaw (mandible) forwards which potentially enlarges the upper airway and increases the upper airspace, improving the respiratory function. To assess the effects of oral appliances or functional orthopaedic appliances for obstructive sleep apnoea in children. We searched the following electronic databases: Cochrane Oral Health's Trials Register (to 7 April 2016); Cochrane Central Register of Controlled Trials (CENTRAL; 2016, Issue 3) in the Cochrane Library (searched 7 April 2016); MEDLINE Ovid (1946 to 7 April 2016); Embase Ovid (1980 to 7 April 2016); LILACS BIREME (from 1982 to 7 April 2016); BBO BIREME (from 1986 to 7 April 2016) and SciELO Web of Science (from 1997 to 7 April 2016). We searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform for ongoing trials on 7 April 2016. We placed no restrictions on the language or date of publication when searching the electronic databases. All randomised or quasi-randomised controlled trials comparing all types of oral and functional orthopaedic appliances with placebo or no treatment, in children 15 years old or younger. reduction of apnoea to less than one episode per hour. dental and skeletal relationship, sleep parameters improvement, cognitive and phonoaudiological function, behavioural problems, quality of life, side effects

  19. 42 CFR 84.1149 - Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements. 84.1149 Section 84.1149 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  20. 42 CFR 84.1149 - Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements. 84.1149 Section 84.1149 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  1. 42 CFR 84.1149 - Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements. 84.1149 Section 84.1149 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  2. 42 CFR 84.1149 - Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements. 84.1149 Section 84.1149 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  3. 42 CFR 84.1149 - Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements. 84.1149 Section 84.1149 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  4. Gallbladder Polyp Mimicking an Obstructive Calculus

    PubMed Central

    Bass, James; Fegelman, Ronald H.

    1978-01-01

    The second documented case of obstructing polyp of the gallbladder—an extremely rare lesion—is presented. Symptoms were indistinguishable from those of acute obstructive cholecystitis. The mechanism of obstruction is hypothesized. ImagesFigure 1 PMID:702555

  5. Patient Factors Influencing Respiratory-Related Clinician Actions in Chronic Obstructive Pulmonary Disease Screening.

    PubMed

    Wadland, William C; Zubek, Valentina Bayer; Clerisme-Beaty, Emmanuelle M; Ríos-Bedoya, Carlos F; Yawn, Barbara P

    2017-01-01

    The purpose of this study was to identify patient-related factors that may explain the increased likelihood of receiving a respiratory-related clinician action in patients identified to be at risk for chronic obstructive pulmonary disease in a U.S.-based pragmatic study of chronic obstructive pulmonary disease screening. This post hoc analysis (conducted in 2014-2015) of the Screening, Evaluating and Assessing Rate Changes of Diagnosing Respiratory Conditions in Primary Care 1 (SEARCH1) study (conducted in 2010-2011), used the chronic obstructive pulmonary disease Population Screener questionnaire in 112 primary care practices. Anyone with a previous chronic obstructive pulmonary disease diagnosis was excluded. Multivariate logistic regression modeling was used to assess patient factors associated with the likelihood of receiving an respiratory-related clinician action following positive screening. Overall, 994 of 6,497 (15%) screened positive and were considered at risk for chronic obstructive pulmonary disease. However, only 187 of the 994 patients (19%) who screened positive received a respiratory-related clinician action. The chances of receiving a respiratory-related clinician action were significantly increased in patients who visited their physician with a respiratory issue (p<0.05) or had already been prescribed a respiratory medication (p<0.05). Most (81%) patients who screened positive or had a respiratory-related clinician action had one or more comorbidity, including cardiovascular disease (68%), diabetes (30%), depression/anxiety (26%), asthma (11%), and cancer (9%). Routine chronic obstructive pulmonary disease screening appears to promote respiratory-related clinician actions in patients with a high likelihood for disease who have respiratory complaints or already use prescribed respiratory medication. Copyright © 2016 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  6. Obstructions in Vascular Networks: Relation Between Network Morphology and Blood Supply

    PubMed Central

    Torres Rojas, Aimee M.; Meza Romero, Alejandro; Pagonabarraga, Ignacio; Travasso, Rui D. M.; Corvera Poiré, Eugenia

    2015-01-01

    We relate vascular network structure to hemodynamics after vessel obstructions. We consider tree-like networks with a viscoelastic fluid with the rheological characteristics of blood. We analyze the network hemodynamic response, which is a function of the frequencies involved in the driving, and a measurement of the resistance to flow. This response function allows the study of the hemodynamics of the system, without the knowledge of a particular pressure gradient. We find analytical expressions for the network response, which explicitly show the roles played by the network structure, the degree of obstruction, and the geometrical place in which obstructions occur. Notably, we find that the sequence of resistances of the network without occlusions strongly determines the tendencies that the response function has with the anatomical place where obstructions are located. We identify anatomical sites in a network that are critical for its overall capacity to supply blood to a tissue after obstructions. We demonstrate that relatively small obstructions in such critical sites are able to cause a much larger decrease on flow than larger obstructions placed in non-critical sites. Our results indicate that, to a large extent, the response of the network is determined locally. That is, it depends on the structure that the vasculature has around the place where occlusions are found. This result is manifest in a network that follows Murray’s law, which is in reasonable agreement with several mammalian vasculatures. For this one, occlusions in early generation vessels have a radically different effect than occlusions in late generation vessels occluding the same percentage of area available to flow. This locality implies that whenever there is a tissue irrigated by a tree-like in vivo vasculature, our model is able to interpret how important obstructions are for the irrigation of such tissue. PMID:26086774

  7. ENVIRONMENTAL TECHNOLOGY VERIFICATION, TEST REPORT OF CONTROL OF BIOAEROSOLS IN HVAC SYSTEMS, AIRFLOW PRODUCTS AFP30

    EPA Science Inventory

    The Environmental Technology Verification report discusses the technology and performance of the AFP30 air filter for dust and bioaerosol filtration manufactured by Airflow Products. The pressure drop across the filter was 62 Pa clean and 247 Pa dust loaded. The filtration effici...

  8. Comparison of radiography and ultrasonography for diagnosing small-intestinal mechanical obstruction in vomiting dogs.

    PubMed

    Sharma, Ajay; Thompson, Margret S; Scrivani, Peter V; Dykes, Nathan L; Yeager, Amy E; Freer, Sean R; Erb, Hollis N

    2011-01-01

    A cross-sectional study was performed on acutely vomiting dogs to compare the accuracy of radiography and ultrasonography for the diagnosis of small-intestinal mechanical obstruction and to describe several radiographic and ultrasonographic signs to identify their contribution to the final diagnosis. The sample population consisted of 82 adult dogs and small-intestinal obstruction by foreign body was confirmed in 27/82 (33%) dogs by surgery or necropsy. Radiography produced a definitive result (obstructed or not obstructed) in 58/82 (70%) of dogs; ultrasonography produced a definitive result in 80/82 (97%) of dogs. On radiographs, a diagnosis of obstruction was based on detection of segmental small-intestinal dilatation, plication, or detection of a foreign body. Approximately 30% (8/27) of obstructed dogs did not have radiographic signs of segmental small-intestinal dilatation, of which 50% (4/8) were due to linear foreign bodies. The ultrasonographic diagnosis of small-intestinal obstruction was based on detection of an obstructive lesion, sonographic signs of plication or segmental, small-intestinal dilatation. The ultrasonographic presence or absence of moderate-to-severe intestinal diameter enlargement (due to lumen dilatation) of the jejunum (>1.5 cm) was a useful discriminatory finding and, when present, should prompt a thorough search for a cause of small-intestinal obstruction. In conclusion, both abdominal radiography and abdominal ultrasonography are accurate for diagnosing small-intestinal obstruction in vomiting dogs and either may be used depending on availability and examiner choice. Abdominal ultrasonography had greater accuracy, fewer equivocal results and provided greater diagnostic confidence compared with radiography. © 2010 Veterinary Radiology & Ultrasound.

  9. Study of the burden on patients with chronic obstructive pulmonary disease

    PubMed Central

    Izquierdo, J L; Barcina, C; Jiménez, J; Muñoz, M; Leal, M

    2009-01-01

    Background: Health-related quality of life measures are widely used in patients with chronic obstructive pulmonary disease (COPD). However, they are extremely limited when used to evaluate patients outside the clinical trials. The aim of this study was to analyse the burden of the disease using a simple, validated, self-administered questionnaire specifically developed for patients in daily clinical practice. Methods: A total of 3935 patients (74.5% men; mean age, 67 years) participated in a cross-sectional study. The burden of COPD on patients was measured using the Clinical COPD Questionnaire (CCQ). COPD was rated at four levels by the forced expiratory volume in one second (FEV1) according to The Global Initiative for Chronic Obstructive Lung Disease (GOLD) scale. Results: The disease mainly affects old men (more than 50% were over 65 years of age) and non-employed men (23% were employed). Of the patients studied, 22.7% continued smoking, especially men (24.4% of men vs. 18.1% of women). Most patients (54%) were diagnosed with moderate stage II COPD. Severity of COPD was lower in women: 29.6% of men had severe COPD compared with 13.7% of women. During the last year, 65.1% had at least one acute exacerbation and 36.6% were admitted to hospital because of COPD exacerbation. No association was found between the body mass index and COPD stage. The variable that most influenced the disease burden was dyspnoea, as progression from grade 0 to grade 4 increased the disease burden by 1.78 points for symptoms, 2.43 for functional state and 1.53 for mental state. The functional classification of COPD also had a significant influence on the disease burden. Conclusions: The present findings show that dyspnoea and the degree of airflow limitation are the clinical variables that most affect the burden of COPD from the patient’s point of view. PMID:19125996

  10. The role of drug-induced sleep endoscopy in surgical planning for obstructive sleep apnea syndrome.

    PubMed

    Aktas, Ozturk; Erdur, Omer; Cirik, Ahmet Adnan; Kayhan, Fatma Tulin

    2015-08-01

    This study investigated the role of drug-induced sleep endoscopy (DISE) in the surgical treatment planning of patients with obstructive sleep apnea syndrome (OSAS). This study was conducted using patients diagnosed with OSAS between January 2007 and March 2009, who were scheduled for surgical treatment. DISE was performed using propofol in patients considered to have upper respiratory tract obstruction as indicated by Muller's maneuver. After completing the sleep endoscopy, the patient was intubated and surgery was performed (tonsillectomy and uvulopalatopharyngoplasty). A successful operation was defined as a decrease in the respiratory disturbance index to below 5 or a decrease of ≥50 % following the operation. The study included 20 patients (4 female and 16 male) aged 19-57 years. No statistically significant correlation between modified Mallampati class and operation success or between the polysomnographic stage of disease and operation success was identified. A significantly high operation success rate was found in the group with obstruction of the upper airway according to DISE (p < 0.05), whereas a significantly low operation success rate was found in the group with obstruction of the lower airway according to DISE (p < 0.01). DISE may be used to identify the localization of obstruction for diagnostic purposes, and it can be helpful in selecting the treatment method.

  11. Agreement between Results of Home Sleep Testing for Obstructive Sleep Apnea with and without a Sleep Specialist

    PubMed Central

    Aurora, R. Nisha; Putcha, Nirupama; Swartz, Rachel; Punjabi, Naresh M.

    2016-01-01

    Background Obstructive sleep apnea is a prevalent yet underdiagnosed condition associated with cardiovascular morbidity and mortality. Home sleep testing offers an efficient means for diagnosing obstructive sleep apnea but has primarily been deployed in clinical samples with a high pretest probability. The current study sought to assess if obstructive sleep apnea can be diagnosed with home sleep testing in a non-referred sample without involvement of a sleep medicine specialist. Methods A study of community-based adults with untreated obstructive sleep apnea was undertaken. Misclassification of disease severity based on home sleep testing with and without involvement of a sleep medicine specialist was assessed, and agreement was characterized using scatter plots, Pearson's correlation coefficient, Bland-Altman analysis, and the kappa statistic. Analyses were also conducted to assess whether any observed differences varied as a function of pretest probability of obstructive sleep apnea or subjective sleepiness. Results The sample consisted of 191 subjects with over half (56.5%) having obstructive sleep apnea. Without involvement of a sleep medicine specialist, obstructive sleep apnea was not identified in only 5.8% of the sample. Analyses comparing the categorical assessment of disease severity with and without a sleep medicine specialist showed that in total, 32 subjects (16.8%) were misclassified. Agreement in the disease severity with and without a sleep medicine specialist was not influenced by the pretest probability or daytime sleep tendency. Conclusion Obstructive sleep apnea can be reliably identified with home sleep testing in a non-referred sample irrespective of the pretest probability of the disease. PMID:26968467

  12. Agreement Between Results of Home Sleep Testing for Obstructive Sleep Apnea with and Without a Sleep Specialist.

    PubMed

    Aurora, R Nisha; Putcha, Nirupama; Swartz, Rachel; Punjabi, Naresh M

    2016-07-01

    Obstructive sleep apnea is a prevalent yet underdiagnosed condition associated with cardiovascular morbidity and mortality. Home sleep testing offers an efficient means for diagnosing obstructive sleep apnea but has been deployed primarily in clinical samples with a high pretest probability. The present study sought to assess whether obstructive sleep apnea can be diagnosed with home sleep testing in a nonreferred sample without involvement of a sleep medicine specialist. A study of community-based adults with untreated obstructive sleep apnea was undertaken. Misclassification of disease severity according to home sleep testing with and without involvement of a sleep medicine specialist was assessed, and agreement was characterized using scatter plots, Pearson's correlation coefficient, Bland-Altman analysis, and the κ statistic. Analyses were also conducted to assess whether any observed differences varied as a function of pretest probability of obstructive sleep apnea or subjective sleepiness. The sample consisted of 191 subjects, with more than half (56.5%) having obstructive sleep apnea. Without involvement of a sleep medicine specialist, obstructive sleep apnea was not identified in only 5.8% of the sample. Analyses comparing the categorical assessment of disease severity with and without a sleep medicine specialist showed that in total, 32 subjects (16.8%) were misclassified. Agreement in the disease severity with and without a sleep medicine specialist was not influenced by the pretest probability or daytime sleep tendency. Obstructive sleep apnea can be reliably identified with home sleep testing in a nonreferred sample, irrespective of the pretest probability of the disease. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Congenital Vitelline Band Causing Intestinal Obstruction in an Adult with a Double Inferior Vena Cava

    PubMed Central

    Pussepitiya, Kumari; Samarasinghe, Bandula; Wickramasinghe, Nuwan

    2016-01-01

    Introduction. Vitelline artery remnants are rare causes of intra-abdominal bands leading to bowel obstruction. These bands may be associated with Meckel's diverticulum. Double inferior vena cava (IVC) is a rare presentation and is usually identified incidentally. Case Presentation. A sixty-year-old male presented with progressive vomiting for five days and he was clinically diagnosed with intestinal obstruction. Plain X-ray abdomen showed evidence of small bowel obstruction. CT scan of the abdomen revealed dilated small bowel loops with a small outpouching in the distal ileum with a band like structure attached to it. In the CT, left sided patent IVC draining into the left renal vein was identified. Left external iliac vein was in continuity with the left IVC. Left internal iliac vein was draining into the right IVC. Exploratory laparotomy revealed a Meckel's diverticulum with a band identified as the vitelline remnant attached to its apex and inserting at the anterior abdominal wall near the umbilicus. Discussion. Meckel's diverticulum with vitelline bands, although rare, should be borne in mind in adult patients with intestinal obstruction. Identification of this anomaly can be difficult in imaging studies. Presence of double IVC should be mentioned in the imaging findings to prevent possible catastrophic complications during surgery. PMID:27843667

  14. [The importance of lung volumes in the investigation of heavy smokers].

    PubMed

    Ben Saad, H; Ben Amor, L; Ben Mdalla, S; Ghannouchi, I; Ben Essghair, M; Sfaxi, R; Garrouche, A; Rouatbi, N; Rouatbi, S

    2014-01-01

    Lung hyperinflation (LH) has become a major concern in the management of chronic obstructive pulmonary disease (COPD). To evaluate the role of lung volumes in the positive diagnosis of COPD and in the assessment of airway obstruction reversibility. Three hundred and sixty-six male smokers over the age of 35 with more than 40 pack-years exposure were included in the study. Plethysmographic data were determined before/after taking a bronchodilator (BBD, ABD). Applied definitions: airflow obstruction: BBD FEV1/FVC<0.70. LH: BBD residual volume (RV)>upper limit of normal. Expressions of reversibility: Δvariable=(ABD-BBD) values; Δinit%=Δvariable/BBD value and Δref%=Δvariable/reference value. A 12%init and a 0.2L increase in either FEV1 or FVC or a 10%ref or - 300 mL decrease in RV were considered as clinically significant. Over the 85 smokers without airflow obstruction, 68% had LH. In the hyperinflated group (n=314), and compared to changes in FEV1 and FVC, these RV changes detected more respondents (54% for FEV1 and FVC vs. 65% for RV, P=0.002). This was not the case for the group free from LH (n=52) (23% for FEV1 and FVC vs. 35% for RV, P=0.09). In the 58 hyperinflated groups free from airflow obstruction, and compared to changes in FEV1 and FVC, changes in RV detected more respondents (24% for FEV1 and FVC vs. 71% for RV, P=0.0001). In heavy smokers, it seems essential to include LH as a criterion for a positive diagnosis of COPD and of reversibility evaluation. Copyright © 2013 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  15. Post-obstructive pulmonary edema from aspirated nuts.

    PubMed

    Bashir, Ahsan; Ahmad, Sabina Qureshi; Silverman, Joshua; Concepcion, Emily; Lee, Haesoon

    2017-01-01

    Post-obstructive pulmonary edema is thought to occur from hemodynamic changes secondary to forced inspiration against the closed airway due to acute or chronic airway obstruction. We report a case of a 13 month-old boy who developed pulmonary edema from aspirated foreign body, nuts. He underwent emergency bronchoscopy to confirm the clinical diagnosis of aspirated nuts in the trachea and nuts were removed endoscopically. His trachea was then intubated and he was mechanically ventilated with oxygen. He developed florid pulmonary edema early in the course with tracheal obstruction and during endoscopic removal of nuts. After removal of obstruction he was ventilated mechanically and pulmonary edema cleared rapidly. Aspirated nuts obstructing trachea can induce obstructive pulmonary edema. Early recognition of foreign body obstruction based on clinical history and its removal resolved pulmonary edema.

  16. The Fate of Nephrons in Congenital Obstructive Nephropathy: Adult Recovery is Limited by Nephron Number Despite Early Release of Obstruction.

    PubMed

    Sergio, Maria; Galarreta, Carolina I; Thornhill, Barbara A; Forbes, Michael S; Chevalier, Robert L

    2015-11-01

    Urinary tract obstruction and reduced nephron number often occur together as a result of maldevelopment of the kidneys and the urinary tract. We determined the role of nephron number on adaptation of the remaining nephrons of mice subjected to neonatal partial unilateral ureteral obstruction followed through adulthood. Wild-type and Os/+ mice (the latter with 50% fewer nephrons) underwent sham operation or partial unilateral ureteral obstruction in the first 2 days of life. Additional mice underwent release of unilateral ureteral obstruction at 7 days. All kidneys were harvested at 3 weeks (weaning) or 6 weeks (adulthood). Glomerular number and area, glomerulotubular junction integrity, proximal tubular volume fraction and interstitial fibrosis were measured by histomorphometry. In the obstructed kidney unilateral ureteral obstruction caused additional nephron loss in Os/+ but not in wild-type mice. Glomerular growth from 3 to 6 weeks was impaired by ipsilateral obstruction and not preserved by release in wild-type or Os/+ mice. Proximal tubular growth was impaired and interstitial collagen was increased by ipsilateral obstruction in all mice. These conditions were attenuated by release of unilateral ureteral obstruction in wild-type mice but were not restored in Os/+ mice. Unilateral ureteral obstruction increased interstitial collagen in the contralateral kidney while release of obstruction enhanced tubular growth and reduced interstitial collagen. Unilateral ureteral obstruction in early postnatal development impairs adaptation to reduced nephron number and induces additional nephron loss despite release of obstruction. Premature and low birth weight infants with congenital obstructive nephropathy are likely at increased risk for progression of chronic kidney disease. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  17. 42 CFR 84.157 - Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... respirator, pressure-demand class; minimum requirements. 84.157 Section 84.157 Public Health PUBLIC HEALTH... test; Type C supplied-air respirator, pressure-demand class; minimum requirements. (a) The static... the facepiece shall not fall below atmospheric at inhalation airflows less than 115 liters (4 cubic...

  18. 42 CFR 84.157 - Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... respirator, pressure-demand class; minimum requirements. 84.157 Section 84.157 Public Health PUBLIC HEALTH... test; Type C supplied-air respirator, pressure-demand class; minimum requirements. (a) The static... the facepiece shall not fall below atmospheric at inhalation airflows less than 115 liters (4 cubic...

  19. RAGE and tobacco smoke: insights into modeling chronic obstructive pulmonary disease

    PubMed Central

    Robinson, Adam B.; Stogsdill, Jeffrey A.; Lewis, Joshua B.; Wood, Tyler T.; Reynolds, Paul R.

    2012-01-01

    Chronic obstructive pulmonary disease (COPD) is a progressive condition characterized by chronic airway inflammation and airspace remodeling, leading to airflow limitation that is not completely reversible. Smoking is the leading risk factor for compromised lung function stemming from COPD pathogenesis. First- and second-hand cigarette smoke contain thousands of constituents, including several carcinogens and cytotoxic chemicals that orchestrate chronic lung inflammation and destructive alveolar remodeling. Receptors for advanced glycation end-products (RAGE) are multi-ligand cell surface receptors primarily expressed by diverse lung cells. RAGE expression increases following cigarette smoke exposure and expression is elevated in the lungs of patients with COPD. RAGE is responsible in part for inducing pro-inflammatory signaling pathways that culminate in expression and secretion of several cytokines, chemokines, enzymes, and other mediators. In the current review, new transgenic mouse models that conditionally over-express RAGE in pulmonary epithelium are discussed. When RAGE is over-expressed throughout embryogenesis, apoptosis in the peripheral lung causes severe lung hypoplasia. Interestingly, apoptosis in RAGE transgenic mice occurs via conserved apoptotic pathways also known to function in advanced stages of COPD. RAGE over-expression in the adult lung models features of COPD including pronounced inflammation and loss of parenchymal tissue. Understanding the biological contributions of RAGE during cigarette smoke-induced inflammation may provide critically important insight into the pathology of COPD. PMID:22934052

  20. Management of extremely low birth weight neonates with bowel obstruction within 2 weeks after birth.

    PubMed

    Hatanaka, Akira; Nakahara, Saori; Takeyama, Eriko; Iwanaka, Tadashi; Ishida, Kazuo

    2014-12-01

    The majority of bowel obstructions in extremely low birth weight (ELBW) neonates are meconium-related ileus (MRI). ELBW neonates with bowel obstruction may recover by conservative treatment, but some do not. Considering the high surgical morbidity rates, unnecessary surgery should be avoided. We sought to identify a reasonable treatment strategy under these conditions. ELBW neonates who started to have bowel obstruction with an unclear cause within 14 days of age were enrolled. The study period was from January 2009 to August 2011. The enrolled patients had daily Gastrografin(®) enemas until 14 days of age or until the obstruction resolved. If the obstruction lasted beyond around 14 days of age, the patient underwent surgical intervention. The clinical data of the patients were collected and analyzed. Fourteen patients were enrolled. Twelve patients had MRI, which resolved within 14 days without surgery. Two patients with persistent obstruction underwent surgery, and they were found to have Hirschsprung's disease and ileal volvulus, respectively. For ELBW neonates with bowel obstruction of unclear etiology, the early and frequent administration of a Gastrografin(®) enema is reasonable. Surgery should be considered if the obstruction lasts beyond approximately 14 days after birth.