Contribution of TIGA reprocessing to the ITRF densification
NASA Astrophysics Data System (ADS)
Rudenko, S.; Dähnn, M.; Gendt, G.; Brandt, A.; Nischan, T.
2009-04-01
Analysis of tide gauge measurements with the purpose of sea level change investigations requires a well defined reference frame. Such reference frame can be realized through precise positions of GPS stations located at or near tide gauges (TIGA stations) and analyzed within the IGS GPS Tide Gauge Benchmark Monitoring Pilot Project (TIGA). To tie this reference frame to the International Terrestrial Reference Frame (ITRF), one should process simultaneously GPS data from TIGA and IGS stations included in the ITRF. A time series of GPS station positions has been recently derived by reprocessing GPS data from about 400 GPS stations globally distributed covering totally time span from 1998 till 2008 using EPOS-Potsdam software developed at GFZ and improved in the recent years. The analysis is based on the use of IERS Conventions 2003, ITRF2005 as a priori reference frame, FES2004 ocean tide loading model, absolute phase centre variations for GPS satellite transmit and ground receive antennae and other models. About 220 stations of the solution are IGS ones and about 180 are TIGA GPS stations that are not IGS ones. The solution includes weekly coordinates of GPS stations, daily values of the Earth rotation parameters and their rates, as well as satellite antenna offsets. On the other hand, our new solution can contribute to the ITRF densification by providing positions of about 200 stations being not present in ITRF2005. The solution can be also used for the integration of regional frames. The paper presents the results of the analysis and the comparison of our solution with ITRF2005 and the solutions of other TIGA and IGS Analysis Centres.
Station Coordinates Combination Status and Contribution to ITRF2005
NASA Astrophysics Data System (ADS)
Ferland, R.
2007-12-01
Under the auspices of the International GNSS Service (IGS), the Reference Frame Working Group combines at Natural Resources Canada (NRCan) an accurate and consistent set of station coordinates, velocities and Earth Rotation Parameters (ERP) that are updated weekly. The consistency of these parameters is ensured by simultaneously combining them using their full variance-covariance information. The IGS Analysis Centers (ACs) (cod, emr, esa, gfz, jpl, mit, ngs, sio) provide the solutions used in the IGS weekly combination. The Global Network Associates Analysis Centers (GNAAC) (mit, ncl) also generate weekly combined solutions that include consistent station coordinates and ERPs. Those GNAAC solutions are used for comparisons and quality control of the IGS weekly solution. In recent weeks each AC has been contributing between about 50 and 250 station coordinates estimates. The combined product currently approaches 300 stations. Of those, between 40 and 110 are used for the current IGS reference frame realization of the ITRF2005 in each AC solution. The quality of the AC station coordinates solutions has improved significantly since they have started contributing in early 1996. This is due to the densification of the network of stations along with gradual improvements in station hardware and processing software. For recent solutions, the estimated noise (std. dev.) level between the AC weekly solutions and the different combined solutions varies between 1-3mm horizontally and 2-10mm vertically. More details about the statistics, their evolution and differences between the ACs will be presented. IGS weekly station coordinates and ERP combined products have also been contributed to the ITRF2005. Those weekly solutions were all recombined from the original AC contributions, going back to the beginning of 1996. The recombined solutions were edited for known problems (e.g. incorrect antenna heights and outliers). Several stations with short time span were also removed. A list of station coordinates discontinuities was also prepared, in collaboration with several individuals and contributed to the IERS. Since November 5, 2006 (GPS week 1400), the IGS has implemented a realization of ITRF2005. It includes mainly the change from relative to absolute antenna phase centers and an update of the selected reference frame stations for the new realization. An expected change of scale from about 3 ppb to -0.7 ppb caused by the phase center shift was observed.
IGS14/igs14.atx: a new Framework for the IGS Products
NASA Astrophysics Data System (ADS)
Rebischung, P.; Schmid, R.
2016-12-01
The International GNSS Service (IGS) is about to switch to a new reference frame (IGS14), based on the latest release of the International Terrestrial Reference Frame (ITRF2014), as the basis for its products. An updated set of satellite and ground antenna calibrations (igs14.atx) will become effective at the same time. IGS14 and igs14.atx will then replace the previous IGS08/igs08.atx framework in use since GPS week 1632 (17 April 2011) and in the second IGS reprocessing campaign (repro2). Despite the negligible scale difference between ITRF2008 and ITRF2014 (0.02 ppb), the radial components of all GPS and GLONASS satellite antenna phase center offsets (z-PCOs) had to be updated in igs14.atx, because of modeling changes recently introduced within the IGS that affect the scale of the IGS products. This was achieved by deriving and averaging time series of satellite z-PCO estimates, consistent with the ITRF2014 scale, from the daily repro2 and latest operational SINEX solutions of seven IGS Analysis Centers (ACs). Compared to igs08.atx, igs14.atx includes robot calibrations for 16 additional ground antenna types, so that the percentage of stations with absolute calibrations in the IGS network will reach 90% after the switch. 19 type-mean robot calibrations were also updated thanks to the availability of calibration results for additional antenna samples. IGS14 is basically an extract of well-suited reference frame stations (i.e., with long and stable position time series) from ITRF2014. However, to make the IGS14 station coordinates consistent with the new igs14.atx ground antenna calibrations, position offsets due to the switch from igs08.atx to igs14.atx were derived for all IGS14 stations affected by ground antenna calibration updates and applied to their ITRF2014 coordinates. This presentation will first detail the different steps of the elaboration of IGS14 and igs14.atx. The impact of the switch on GNSS-derived geodetic parameter time series will then be assessed by re-aligning the daily repro2 and latest operational IGS combined SINEX solutions to IGS14/igs14.atx. A particular focus will finally be given to the biases and trends present in the satellite z-PCO time series derived from the daily AC SINEX solutions, and to their interpretation in terms of scale and scale rate of the terrestrial frame.
Preparations for the IGS realization of ITRF2014
NASA Astrophysics Data System (ADS)
Rebischung, Paul; Schmid, Ralf
2016-04-01
The International GNSS Service (IGS) currently prepares its own realization, called IGS14, of the latest release of the International Terrestrial Reference Frame (ITRF2014). This preparation involves: - a selection of the most suitable reference frame (RF) stations from the complete set of GNSS stations in ITRF2014; - the design of a well-distributed core network of RF stations for the purpose of aligning global GNSS solutions; - a re-evaluation of the GPS and GLONASS satellite antenna phase center offsets (PCOs), based on the SINEX files provided by the IGS Analysis Centers (ACs) in the frame of the second IGS reprocessing campaign repro2. This presentation will first cover the criteria used for the selection of the IGS14 and IGS14 core RF stations as well as preliminary station selection results. We will then use the preliminary IGS14 RF to re-align the daily IGS combined repro2 SINEX solutions and study the impact of the RF change on GNSS-derived geodetic parameter time series. In a second part, we will focus on the re-evaluation of the GNSS satellite antenna PCOs. A re-evaluation of at least their radial (z) components is indeed required, despite the negligible scale difference between ITRF2008 and ITRF2014, because of modeling changes recently introduced within the IGS which affect the scale of GNSS terrestrial frames (Earth radiation pressure, antenna thrust). Moreover, the 13 GPS and GLONASS satellites launched since September 2012 are currently assigned preliminary block-specific mean PCO values which need to be updated. From the daily AC repro2 SINEX files, we will therefore derive time series of satellite z-PCO estimates and analyze the resulting time series. Since several ACs provided all three components of the satellite PCOs in their SINEX files, we will additionally derive similar x- and y-PCO time series and discuss the relevance of their potential re-evaluation.
SIRGAS: ITRF densification in Latin America and the Caribbean
NASA Astrophysics Data System (ADS)
Brunini, C.; Costa, S.; Mackern, V.; Martínez, W.; Sánchez, L.; Seemüller, W.; da Silva, A.
2009-04-01
The continental reference frame of SIRGAS (Sistema de Referencia Geocéntrico para las Américas) is at present realized by the SIRGAS Continuously Operating Network (SIRGAS-CON) composed by about 200 stations distributed over all Latin America and the Caribbean. SIRGAS member countries are qualifying their national reference frames by installing continuously operating GNSS stations, which have to be consistently integrated into the continental network. As the number of these stations is rapidly increasing, the processing strategy of the SIRGAS-CON network was redefined during the SIRGAS 2008 General Meeting in May 2008. The new strategy relies upon the definition of two hierarchy levels: a) A core network (SIRGAS-CON-C) with homogeneous continental coverage and stabile site locations ensures the long-term stability of the reference frame and provides the primary link to the ITRS. Stations belonging to this network have been selected so that each country contributes with a number of stations defined according to its surface and guarantying that the selected stations are the best in operability, continuity, reliability, and geographical coverage. b) Several densification sub-networks (SIRGAS-CON-D) improve the accessibility to the reference frame. The SIRGAS-CON-D sub-networks shall correspond to the national reference frames, i.e., as an optimum there shall be as many sub-networks as countries in the region. The goal is that each country processes its own continuously stations following the SIRGAS processing guidelines, which are defined in accordance with the IERS and IGS standards and conventions. Since at present not all of the countries are operating a processing centre, the existing stations are classified in three densification networks (a Northern, a middle, and a Southern one), which are processed by three local processing centres until new ones are installed. As SIRGAS is defined as a densification of the ITRS, stations included in the core network, as well as in the densification sub-networks match the requirements, characteristics, and processing performance of the ITRF. The SIRGAS-CON-C network is processed by DGFI (Deutsches Geodätisches Forschungsinstitut, Germany) as the IGS-RNAAC-SIR. The Local Processing Centres are for the Northern sub-network IGAC (Instituto Geográfico Augustín Codazzi, Colombia), for the middle sub-network IBGE (Instituto Brasileiro de Geografia e Estátistica, Brazil), and for the Southern sub-network IGG-CIMA (Instituto de Geodesia y Geodinámica, Universidad Nacional de Cuyo, Argentina). These four Processing Centres deliver loosely constrained weekly solutions for station coordinates (i.e., satellite orbits, satellite clock offsets, and Earth orientation parameters are fixed to the final weekly IGS solutions and coordinates for all sites are constrained to 1 m). The individual contributions are integrated in a unified solution by the SIRGAS Combination Centres (DGFI and IBGE) according to the following strategy: 1) Individual solutions are reviewed/corrected for possible format problems, data inconsistencies, etc. 2) Constraints imposed in the delivered normal equations are removed. 3) Sub-networks are individually aligned to the IGS05 reference frame by applying the No Net Rotation (NNR) and No Net Translation (NNT) conditions. 4) Coordinates obtained in (3) for each sub-network are compared to IGS05 values and to each other in order to identify possible outliers. 5) Stations with large residuals (more than 10 mm in the N-E component, and more than 20 mm in the Up component) are reduced from the normal equations. Steps (3), (4), and (5) are done iteratively. 6) Since at present the four Analysis Centres are processing GPS observations only and all of them use the Bernese Software for computing weekly solutions, relative weighting factors are not applied in the combination. 7) Individual normal equations are accumulated and solved for computing a loosely constrained weekly solution for station coordinates (i.e., coordinates for all stations are constrained to 1 m). This solution in SINEX format is submitted to IGS for the global polyhedron. 8) Combination obtained in (7) is constrained by applying NNR+NNT conditions with respect to the IGS05 stations included the SIRGAS region to provide constrained coordinates for all SIRGAS-CON (core + densification) stations. The applied IGS05 reference coordinates correspond to the weekly IGS solution for the global network, i.e., coordinates included in the igsYYPwwww.snx files. This constrained solution provides the final weekly SIRGAS-CON coordinates for practical applications. The DGFI (i.e. IGS RNAAC SIR) weekly combinations are delivered to the IGS Data Centres for combination in the global polyhedron, and made available for users as official SIRGAS products, respectively. The IBGE weekly combinations provide control and back-up. The above described analysis strategy is applied since GPS week 1495. Before (since June 1996 to August 2008), the SIRGAS-CON network was totally processed by DGFI. Until now, results show a very good agreement with previous computations; however, the present sub-networks distribution has two main disadvantages: 1) Not all SIRGAS-CON stations are included in the same number of individual solutions, i.e., they are unequally weighted in the weekly combinations, and 2) since there are not enough Local Processing Centres, the required redundancy (each station processed by at least three processing centres) is not fulfilled. Therefore, efforts are being made to install additional Local Processing Centres in Latin American countries as Argentina, Ecuador, Mexico, Peru, Uruguay, and Venezuela.
Non-linear motions in reprocessed GPS station position time series
NASA Astrophysics Data System (ADS)
Rudenko, Sergei; Gendt, Gerd
2010-05-01
Global Positioning System (GPS) data of about 400 globally distributed stations obtained at time span from 1998 till 2007 were reprocessed using GFZ Potsdam EPOS (Earth Parameter and Orbit System) software within International GNSS Service (IGS) Tide Gauge Benchmark Monitoring (TIGA) Pilot Project and IGS Data Reprocessing Campaign with the purpose to determine weekly precise coordinates of GPS stations located at or near tide gauges. Vertical motions of these stations are used to correct the vertical motions of tide gauges for local motions and to tie tide gauge measurements to the geocentric reference frame. Other estimated parameters include daily values of the Earth rotation parameters and their rates, as well as satellite antenna offsets. The solution GT1 derived is based on using absolute phase center variation model, ITRF2005 as a priori reference frame, and other new models. The solution contributed also to ITRF2008. The time series of station positions are analyzed to identify non-linear motions caused by different effects. The paper presents the time series of GPS station coordinates and investigates apparent non-linear motions and their influence on GPS station height rates.
An update to the analysis of the Canadian Spatial Reference System
NASA Astrophysics Data System (ADS)
Ferland, R.; Piraszewski, M.; Craymer, M.
2015-12-01
The primary objective of the Canadian Spatial Reference System (CSRS) is to provide users access to a consistent geo-referencing infrastructure over the Canadian landmass. Global Navigation Satellite System (GNSS) positioning accuracy requirements ranges from meter level to mm level (e.g.: crustal deformation). The highest level of the Canadian infrastructure consist of a network of continually operating GPS and GNSS receivers, referred to as active control stations. The network includes all Canadian public active control stations, some bordering US CORS and Alaska stations, Greenland active control stations, as well as a selection of IGS reference frame stations. The Bernese analysis software is used for the daily processing and the combination into weekly solutions which form the basis for this analysis. IGS weekly final orbit, Earth Rotation parameters (ERP's) and coordinates products are used in the processing. For the more demanding users, the time dependant changes of station coordinates is often more important.All station coordinate estimates and related covariance information is used in this analysis. For each input solution, variance factor, translation, rotation and scale (and if needed their rates) or subsets of these are estimated. In the combination of these weekly solutions, station positions and velocities are estimated. Since the time series from the stations in these networks often experience changes in behavior, new (or reuse of) parameters are generally used in these situations. As is often the case with real data, unrealistic coordinates may occur. Automatic detection and removal of outliers is used in these cases. For the transformation, position and velocity parameters loose apriori estimates and uncertainties are provided. Alignment using the usual Helmert transformation to the latest IGb08 realization of ITRF is also performed during the adjustment.
Western Pyrenees geodetic deformation study using the Guipuzcoa GNSS network
NASA Astrophysics Data System (ADS)
Martín, Adriana; Sevilla, Miguel; Zurutuza, Joaquín
2018-07-01
The Basque Country in the north of Spain is located inside the Basque-Cantabrian basin of the western Pyrenees which remarkable seismic-tectonic implications justify the need of geodetic control in the area. In order to perform a crustal deformation study we have analysed all daily observations from the GNSS permanent network of Guipuzcoa and external IGS stations, from January 2007 to November 2011. We have carried out the data processing applying double differences methodology in the automatic processing module BPE (Bernese Processing Engine) from Bernese GNSS software version 5.0. Solution was aligned to geodetic reference framework ITRF2008, by using the IGS08 solution and updated satellite and terrestrial antennas calibration. This five years network study results: Coordinate time series, velocities and baseline lengths variations show internal stability among inner stations and from them with respect to outer IGS stations, concluding that no deformations have been observed.
NASA Astrophysics Data System (ADS)
Abdelazeem, Mohamed; Çelik, Rahmi N.; El-Rabbany, Ahmed
2016-04-01
The international global navigation satellite system (GNSS) real-time service (IGS-RTS) products have been used extensively for real-time precise point positioning and ionosphere modeling applications. In this study, we develop a regional model for real-time vertical total electron content (RT-VTEC) and differential code bias (RT-DCB) estimation over Europe using the IGS-RTS satellite orbit and clock products. The developed model has a spatial and temporal resolution of 1°×1° and 15 minutes, respectively. GPS observations from a regional network consisting of 60 IGS and EUREF reference stations are processed in the zero-difference mode using the Bernese-5.2 software package in order to extract the geometry-free linear combination of the smoothed code observations. The spherical harmonic expansion function is used to model the VTEC, the receiver and the satellite DCBs. To validate the proposed model, the RT-VTEC values are computed and compared with the final IGS-global ionospheric map (IGS-GIM) counterparts in three successive days under high solar activity including one of an extreme geomagnetic activity. The real-time satellite DCBs are also estimated and compared with the IGS-GIM counterparts. Moreover, the real-time receiver DCB for six IGS stations are obtained and compared with the IGS-GIM counterparts. The examined stations are located in different latitudes with different receiver types. The findings reveal that the estimated RT-VTEC values show agreement with the IGS-GIM counterparts with root mean-square-errors (RMSEs) values less than 2 TEC units. In addition, RMSEs of both the satellites and receivers DCBs are less than 0.85 ns and 0.65 ns, respectively in comparison with the IGS-GIM.
TIGA Tide Gauge Data Reprocessing at GFZ
NASA Astrophysics Data System (ADS)
Deng, Zhiguo; Schöne, Tilo; Gendt, Gerd
2014-05-01
To analyse the tide gauge measurements for the purpose of global long-term sea level change research a well-defined absolute reference frame is required by oceanographic community. To create such frame the data from a global GNSS network located at or near tide gauges are processed. For analyzing the GNSS data on a preferably continuous basis the International GNSS Service (IGS) Tide Gauge Benchmark Monitoring Working Group (TIGA-WG) is responsible. As one of the TIGA Analysis Centers the German Research Centre for Geosciences (GFZ) is contributing to the IGS TIGA Reprocessing Campaign. The solutions of the TIGA Reprocessing Campaign will also contribute to 2nd IGS Data Reprocessing Campaign with GFZ IGS reprocessing solution. After the first IGS reprocessing finished in 2010 some improvements were implemented into the latest GFZ software version EPOS.P8: reference frame IGb08 based on ITRF2008, antenna calibration igs08.atx, geopotential model (EGM2008), higher-order ionospheric effects, new a priori meteorological model (GPT2), VMF mapping function, and other minor improvements. GPS data of the globally distributed tracking network of 794 stations for the time span from 1994 until end of 2012 are used for the TIGA reprocessing. To handle such large network a new processing strategy is developed and described in detail. In the TIGA reprocessing the GPS@TIGA data are processed in precise point positioning (PPP) mode to clean data using the IGS reprocessing orbit and clock products. To validate the quality of the PPP coordinate results the rates of 80 GPS@TIGA station vertical movement are estimated from the PPP results using Maximum Likelihood Estimation (MLE) method. The rates are compared with the solution of University of LaRochelle Consortium (ULR) (named ULR5). 56 of the 80 stations have a difference of the vertical velocities below 1 mm/yr. The error bars of PPP rates are significant larger than those of ULR5, which indicates large time correlated noise in the PPP solutions.
NASA Astrophysics Data System (ADS)
Chen, Ming; Guo, Jiming; Li, Zhicai; Zhang, Peng; Wu, Junli; Song, Weiwei
2017-04-01
BDS precision orbit determination is a key content of the BDS application, but the inadequate ground stations and the poor distribution of the network are the main reasons for the low accuracy of BDS precise orbit determination. In this paper, the BDS precise orbit determination results are obtained by using the IGS MGEX stations and the Chinese national reference stations,the accuracy of orbit determination of GEO, IGSO and MEO is 10.3cm, 2.8cm and 3.2cm, and the radial accuracy is 1.6cm,1.9cm and 1.5cm.The influence of ground reference stations distribution on BDS precise orbit determination is studied. The results show that the Chinese national reference stations contribute significantly to the BDS orbit determination, the overlap precision of GEO/IGSO/MEO satellites were improved by 15.5%, 57.5% and 5.3% respectively after adding the Chinese stations.Finally, the results of ODOP(orbit distribution of precision) and SLR are verified. Key words: BDS precise orbit determination; accuracy assessment;Chinese national reference stations;reference stations distribution;orbit distribution of precision
NASA Astrophysics Data System (ADS)
Kazancı, Selma Zengin; Kayıkçı, Emine Tanır
2017-12-01
In recent years, Global Navigation Satellite Systems (GNSS) have gained great importance in terms of the benefi ts it provides such as precise geodetic point positioning, determining crustal deformations, navigation, vehicle monitoring systems and meteorological applications etc. As in Turkey, for this purpose, each country has set up its own GNSS station networks like Turkish National Permanent RTK Network analyzed precise station coordinates and velocities together with the International GNSS Service, Turkish National Fundamental GPS Network and Turkish National Permanent GNSS Network (TNPGN) stations not only are utilized as precise positioning but also GNSS meteorology studies so total number of stations are increased. This work is related to the reactivated of the TRAB IGS station which was established in Karadeniz Technical University, Department of Geomatics Engineering. Within the COST ES1206 Action (GNSS4SWEC) KTU analysis center was established and Trop-NET system developed by Geodetic Observatory Pecny (GOP, RIGTC) in order to troposphere monitoring. The project titled "Using Regional GNSS Networks to Strengthen Severe Weather Prediction" was accepted to the scientifi c and technological research council of Turkey (TUBITAK). With this project, we will design 2 new constructed GNSS reference station network. Using observation data of network, we will compare water vapor distribution derived by GNSS Meteorology and GNSS Tomography. At this time, KTU AC was accepted as E-GVAP Analysis Centre in December 2016. KTU reference station is aimed to be a member of the EUREF network with these studies.
IGS 1996 Analysis Center Workshop
NASA Technical Reports Server (NTRS)
Neilan, R. E. (Editor); VanScoy, P. A. (Editor); Zumberge, J. F. (Editor)
1996-01-01
Components of the IGS[International GPS (Global Positioning System) Service for geodynamics], have operated a GPS tracking system for several years. The network now contains more than 100 stations and has produced a combined GPS ephemeris that has become the standard for geodesists and geophysicists worldwide. IGS data and products are freely available to all thanks to the cooperation and participation of all the IGS members. The IGS has initiated development of several new products, and technical issues permitting greater accuracy of IGS products have been identified. The IGS convened a workshop on March 1996 in Silver Spring, Maryland, USA, to coordinate these developments and to examine technical problems and solutions. The following topics were addressed: orbit/clock combination; Earth orientation; antenna calibration; SINEX and densification of the International Terrestrial Reference Frame (ITRF) using the GPS; receiver standards and performance; and atmospheric topics.
Estimating Real-Time Zenith Tropospheric Delay over Africa Using IGS-RTS Products
NASA Astrophysics Data System (ADS)
Abdelazeem, M.
2017-12-01
Zenith Tropospheric Delay (ZTD) is a crucial parameter for atmospheric modeling, severe weather monitoring and forecasting applications. Currently, the international global navigation satellite system (GNSS) real-time service (IGS-RTS) products are used extensively in real-time atmospheric modeling applications. The objective of this study is to develop a real time zenith tropospheric delay estimation model over Africa using the IGS-RTS products. The real-time ZTDs are estimated based on the real-time precise point positioning (PPP) solution. GNSS observations from a number of reference stations are processed over a period of 7 days. Then, the estimated real-time ZTDs are compared with the IGS tropospheric products counterparts. The findings indicate that the estimated real-time ZTDs have millimeter level accuracy in comparison with the IGS counterparts.
International GPS Service 2001 - 2002 Technical Reports
NASA Technical Reports Server (NTRS)
Gowey, Ken (Editor); Neilan, Ruth (Editor); Moore, Angelyn (Editor)
2004-01-01
Applications of the Global Positioning System (GPS) to Earth Science are numerous. The International GPS Service (IGS), a federation of government agencies and universities, plays an increasingly critical role in support of GPS-related research and engineering activities. Contributions from the IGS Governing Board and Central Bureau, analysis and data centers, station operators, and others constitute the 2001 / 2002 Technical Reports. Hard copies of each volume can be obtained by contacting the IGS Central Bureau at the Jet Propulsion Laboratory. This report is published in black and white. To view graphs or plots that use color to represent data trends or information, please refer to the online PDF version at http://igscb.jpl.nasa.gov/overview/pubs.html.
GNSS station displacement analysis
NASA Astrophysics Data System (ADS)
Haritonova, Diana; Balodis, Janis; Janpaule, Inese; Normand, Madara
2013-04-01
Time series of GNSS station results of both the EUPOS®-Riga and LatPos networks have been developed at the Institute of Geodesy and Geoinformation (University of Latvia). The reference stations from EUREF Permanent Network (EPN) in surroundings of Latvia have been used and Bernese GPS Software, Version 5.0, in both static and kinematic modes was applied. The standard data sets were taken from IGS data base. The results of time series have been analysed and distinctive behaviour of daily and subdaily movements of EUPOS®-Riga and LatPos stations was identified. The reasons of dependence of GNSS station coordinate distribution on possible external factors such as seismic activity of some areas of Latvia and periodic processes were given.
NChina16: A stable geodetic reference frame for geological hazard studies in North China
NASA Astrophysics Data System (ADS)
Wang, Guoquan; Bao, Yan; Gan, Weijun; Geng, Jianghui; Xiao, Gengru; Shen, Jack S.
2018-04-01
We have developed a stable North China Reference Frame 2016 (NChina16) using five years of continuous GPS observations (2011.8-2016.8) from 12 continuously operating reference stations (CORS) fixed to the North China Craton. Applications of NChina16 in landslide and subsidence studies are illustrated in this article. A method for realizing a regional geodetic reference frame is introduced. The primary result of this study is the seven parameters for transforming Cartesian ECEF (Earth-Centered, Earth-Fixed) coordinates X, Y, and Z from the International GNSS Service Reference Frame 2008 (IGS08) to NChina16. The seven parameters include the epoch that is used to align the regional reference frame to IGS08 and the time derivatives of three translations and three rotations. The GIPSY-OASIS (V6.4) software package was used to obtain the precise point positioning (PPP) daily solutions with respect to IGS08. The frame stability of NChina16 is approximately 0.5 mm/year in both horizontal and vertical directions. This study also developed a regional model for correcting seasonal motions superimposed into the vertical component of the GPS-derived displacement time series. Long-term GPS observations (1999-2016) from five CORS in North China were used to develop the seasonal model. According to this study, the PPP daily solutions with respect to NChina16 could achieve 2-3 mm horizontal accuracy and 4-5 mm vertical accuracy after being modified by the regional model. NChina16 will be critical to study geodynamic problems in North China, such as earthquakes, faulting, subsidence, and landslides. The regional reference frame will be periodically updated every few years to mitigate degradation of the frame with time and be synchronized with the update of IGS reference frame.
Status and Future Developments of SIRGAS
NASA Astrophysics Data System (ADS)
Fortes, L.; Lauría, E.; Brunini, C.; Amaya, W.; Sanchez, L.; Drewes, H.
2007-05-01
This paper presents the status and future developments of the SIRGAS (Geocentric Reference System for the Americas) project. Since its creation, in 1993, SIRGAS has coordinated two continental GPS campaigns in 1995 an 2000, responsible for the establishment of a very accurate 3D reference frame in the region. First focusing on South America, the project has expanded its scope to Latin America since 2001. Currently the maintenance of the SIRGAS reference frame is carried out through more than 80 continuous operating GNSS (Global Navigation Satellite System) stations available in the region, whose data is officially processed by the International GNSS Service (IGS) Regional Network Associate Analysis Centre for SIRGAS (IGS RNACC-SIR), functioning at the DGFI (Deutsches Geodatisches Forschungsinstitut), in Munich, to generate weekly coordinates and velocity information of each continuous GNSS station. Since October 2006, five additional experimental processing centers - located at the Brazilian Institute of Geography and Statistics (IBGE), National Institute of Statistics, Geography and Informatics of Mexico (INEGI), Military Geographic Institute of Argentina (IGM), University of La Plata (UNLP), Argentina, and Geographic Institute Agustín Codazzi, Colombia (IGAC) - have also been processing data from those stations in order to assume the official processing responsibility in near future. Many Latin American countries have already adopted SIRGAS as their new official reference system. Besides, efforts have been carried out in order to have the national geodetic networks of Central American countries connected to the SIRGAS reference frame, which will be accomplished by a GNSS campaign scheduled for the first semester of 2007. In terms of vertical datum, SIRGAS continues to coordinate with each member country all the necessary efforts towards making the geodetic leveling data available together with gravity information in order to support the computation of geopotential numbers, to be unified in a continental adjustment.
NASA Technical Reports Server (NTRS)
Moore, A. W.; Neilan, R. E.; Springer, T. A.; Reigber, Ch.
2000-01-01
A strong multipurpose aspect of the International GPS Service (IGS) is revealed by a glance at the titles of current projects and working groups within the IGS: IGS/BIPM Time Transfer Project; Ionosphere Working Group; Troposphere Working Group; International GLONASS Experiment; Working Group on Low-Earth Orbiter Missions; and Tide Gauges, CGPS, and the IGS. The IGS network infrastructure, in large part originally commissioned for geodynamical investigations, has proved to be a valuable asset in developing application-oriented subnetworks whose requirements overlap the characteristics of existing IGS stations and future station upgrades. Issues encountered thus far in the development of multipurpose or multitechnique IGS projects as well as future possibilities will be reviewed.
Results from the JPL IGS Analysis Center IGS14 Reprocessing Campaign
NASA Astrophysics Data System (ADS)
Ries, P. A.; Amiri, N.; Heflin, M. B.; Sakumura, C.; Sibois, A. E.; Sibthorpe, A.; David, M. W.
2017-12-01
The JPL IGS analysis center has begun a campaign to reprocess GPS orbits and clocks in the IGS14 reference frame. Though the new frame is only a few millimeters offset from the previous IGb08 frame, a reprocessing is required for consistent use of the new frame due to a change in the satellite phase center offsets between the frames. We will present results on the reprocessing campaign from 2002 to present in order to evaluate any effects caused by the new frame. We also create long-term time-series and periodograms of translation, rotation, and scale parameters to see if there is any divergence between the frames. We will also process long-term PPP time series and derived velocities for a well-distributed set of stations in each frame to compare with the published frame offsets.
NChina16: A stable geodetic reference frame for geological hazard studies in north China
NASA Astrophysics Data System (ADS)
Wang, G.; Yan, B.; Gan, W.; Geng, J.
2017-12-01
This study established a stable North China Reference Frame 2016 (NChina16) using five years of continuous GPS observations (2011.8 to 2016.8) from 12 continuously operating reference stations (CORS) fixed to the stable interior of the North China Craton. Applications of NChina16 in landslide, subsidence, and post-seismic displacement studies are illustrated. The primary result of this study is the seven parameters for transforming Cartesian ECEF (Earth-Centered, Earth-Fixed) coordinates X, Y, and Z from the International GNSS Service Reference Frame 2008 (IGS08) to NChina16. The seven parameters include the epoch that is used to tie the regional reference frame to IGS08 and the time derivatives of three translations and three rotations. A method for developing a regional geodetic reference frame is introduced in detail. The GIPSY-OASIS (V6.4) software package was used to obtain the precise point positioning (PPP) time series with respect to IGS08. The stability (accuracy) of NChina16 is about 0.5 mm/year in both vertical and horizontal directions. This study also developed a regional seasonal model for correcting vertical displacement time series data derived from the PPP solutions. Long-term GPS observations (1999-2016) from five CORS in north China were used to develop the seasonal model. According to this study, the PPP daily solutions with respect to NChina16 could achieve 2-3 mm horizontal accuracy and 4-5 mm vertical accuracy after being modified by the regional model. NChina16 will be critical to the long-term landslide, subsidence, fault, and structural monitoring in north China and for ongoing post-seismic crustal deformation studies in Japan. NChina16 will be incrementally improved and synchronized with the IGS reference frame update.
Impacts of GNSS position offsets on global frame stability
NASA Astrophysics Data System (ADS)
Griffiths, Jake; Ray, Jim
2015-04-01
Positional offsets appear in Global Navigation Satellite System (GNSS) time series for a variety of reasons. Antenna or radome changes are the most common cause for these discontinuities. Many others are from earthquakes, receiver changes, and different anthropogenic modifications at or near the stations. Some jumps appear for unknown or undocumented reasons. Accurate determination of station velocities, and therefore geophysical parameters and terrestrial reference frames, requires that positional offsets be correctly found and compensated. Williams (2003) found that undetected offsets introduce a random walk error component in individual station time series. The topic of detecting positional offsets has received considerable attention in recent years (e.g., Detection of Offsets in GPS Experiment; DOGEx), and most research groups using GNSS have adopted a mix of manual and automated methods for finding them. The removal of a positional offset from a time series is usually handled by estimating the average station position on both sides of the discontinuity. Except for large earthquake events, the velocity is usually assumed constant and continuous across the positional jump. This approach is sufficient in the absence of time-correlated errors. However, GNSS time series contain periodic and power-law (flicker) errors. In this paper, we evaluate the impact to individual station results and the overall stability of the global reference frame from adding increasing numbers of positional discontinuities. We use the International GNSS Service (IGS) weekly SINEX files, and iteratively insert positional offset parameters. Each iteration includes a restacking of the modified SINEX files using the CATREF software from Institut National de l'Information Géographique et Forestière (IGN). Comparisons of successive stacked solutions are used to assess the impacts on the time series of x-pole and y-pole offsets, along with changes in regularized position and secular velocity for stations with more than 2.5 years of data. Our preliminary results indicate that the change in polar motion scatter is logarithmic with increasing numbers of discontinuities. The best-fit natural logarithm to the changes in scatter for x-pole has R2 = 0.58; the fit for the y-pole series has R2 = 0.99. From these empirical functions, we find that polar motion scatter increases from zero when the total rate of discontinuities exceeds 0.2 (x-pole) and 1.3 (y-pole) per station, on average (the IGS has 0.65 per station). Thus, the presence of position offsets in GNSS station time series is likely already a contributor to IGS polar motion inaccuracy and global frame instability. Impacts to station position and velocity estimates depend on noise features found in that station's positional time series. For instance, larger changes in velocity occur for stations with shorter and noisier data spans. This is because an added discontinuity parameter for an individual station time series can induce changes in average position on both sides of the break. We will expand on these results, and consider remaining questions about the role of velocity discontinuities and the effects caused by non-core reference frame stations.
Sea level rise within the west of Arabian Gulf using tide gauge and continuous GPS measurements
NASA Astrophysics Data System (ADS)
Ayhan, M. E.; Alothman, A.
2009-04-01
Arabian Gulf is connected to Indian Ocean and located in the south-west of the Zagros Trust Belt. To investigate sea level variations within the west of Arabian Gulf, monthly means of sea level at 13 tide gauges along the coast of Saudi Arabia and Bahrain, available in the database of the Permanent Service for Mean Sea Level (PSMSL), are studied. We analyzed individually the monthly means at each station, and estimated secular sea level rate by a robust linear trend fitting. We computed the average relative sea level rise rate of 1.96 ± 0.21 mm/yr within the west of Arabian Gulf based on 4 stations spanning longer than 19 years. Vertical land motions are included into the relative sea level measurements at the tide gauges. Therefore sea level rates at the stations are corrected for vertical land motions using the ICE-5G v1.2 VM4 Glacial Isostatic Adjustment (GIA) model then we found the average sea level rise rate of 2.27 mm/yr. Bahrain International GPS Service (IGS) GPS station, which is close to the Mina Sulman tide gauge station in Bahrain, is the only continuous GPS station accessible in the region. The weekly GPS time series of vertical component at Bahrain IGS-GPS station referring to the ITRF97 from 1999.2 to 2008.6 are downloaded from http://www-gps.mit.edu/~tah/. We fitted a linear trend with an annual signal and one break to the GPS vertical time series and found a vertical land motion rate of 0.48 ± 0.11 mm/yr. Assuming the vertical rate at Bahrain IGS-GPS station represents the vertical rate at each of the other tide gauge stations studied here in the region, we computed average sea level rise rate of 2.44 ± 0.21 mm/yr within the west of Arabian Gulf.
NASA Astrophysics Data System (ADS)
Aerts, W.; Baire, Q.; Bruyninx, C.; Legrand, J.; Pottiaux, E.
2012-12-01
A new multi-GNSS IGS reference station, BRUX, has been installed at Brussels. It replaces the former IGS reference station BRUS, which had to be dismantled because of construction works. The antenna of BRUX is sited on top of a telescope dome. Although this might be an unfortunate choice from an electromagnetic point of view, the siting is very convenient for other reasons. Being close to the time lab hosting the atomic clocks, the cable length is within acceptable and affordable limits, both for cost and signal loss reasons. Moreover, the site offers open sky view, which can indeed be expected from a former telescope siting. The dome is entirely metal, hence shielding of the dome was required in order to mitigate multipath propagation. This was achieved using a metal shield topped with RF absorbing material and respecting a certain antenna-to-absorber spacing in order not to alter the antenna phase center offset (PCO) and variations (PCVs) too much. This would otherwise render the individual calibration of the antenna, in an anechoic chamber in the case of BRUX, invalid. But even taking all precautions, the PCO and PCVs of the calibration do not exactly equal those after installation. Moreover, different calibrations, in an anechoic chamber and by an outdoor robot, of the same antenna have shown to result in PCO and PCVs that differ up to several mm at certain azimuths and elevations. A test set-up with 6 such redundantly calibrated GNSS antennas revealed that the calibration differences can reach 8 mm on the ionosphere-free frequency, which amplifies the calibration differences by a factor three compared to L1 and L2 only. The use of different receiver antenna calibration models can impact position at almost the centimeter level. In an attempt to align the historical time series for BRUS with the (future) data for BRUX, the tie between the new station BRUX and the old IGS station BRUS was determined using terrestrial measurements as well as GPS. In the case of GPS, several L1, L2 and ionosphere-free baseline measurements were performed using state-of-the-art type-mean receiver antenna calibrations as well as individual calibrations. Differences between the different GPS measurements are several mm, while the differences between the terrestrial tie and the GPS ties reaches almost the cm-level. One contribution to the error budget is the absence of an individual calibration for the BRUS antenna, another one is the difference in PCO and PCVs on site, as opposed to at calibration, as already mentioned.
GNSS RTK-networks: The significance and issues to realize a recent reference coordinate system
NASA Astrophysics Data System (ADS)
Umnig, Elke; Möller, Gregor; Weber, Robert
2014-05-01
The upcoming release of the new global reference frame ITRF2013 will provide high accurate reference station positions and station velocities at the mm- and mm/year level, respectively. ITRF users benefit from this development in various ways. For example, this new frame allows for embedding high accurate GNSS baseline observations to an underlying reference of at least the same accuracy. Another advantage is that the IGS products are fully consistent with this frame and therefore all GNSS based zero-difference positioning results (Precise Point Positioning (PPP)) will be aligned to the ITRF2013. Unfortunately the transistion to a new frame (or just to a new epoch) implies also issues in particular for providers and users of real time positioning services. Thus providers have to perform arrangements, such as the readjustment of the reference station coordinates and the update of the transformation parameters from the homogenous GNSS coordinate frame into the national datum. Finally providers have to inform their clients appropriately about these changes and significant adjustments. Furthermore the aspect of the continental reference frame has to be considered: In Europe the use of the continental reference system/reference frame ETRS89/ETRF2000 is, due to cross-national guidelines, recommend by most national mapping authorities. Subsequently GNSS post-processing applications are degraded by the concurrent use of the reference systems and reference frames, to which terrestrial site coordinates and satellite coordinates are aligned. In this presentation we highlight all significant steps and hurdles which have to be jumped over when introducing a new reference frame from point of view of a typical regional RTK-reference station network provider. This network is located in Austria and parts of the neighbouring countries and consists of about 40 reference stations. Moreover, we discuss the significance of permanently monitoring the stability of the reference network sites and the determination of station velocities/rates for geodynamical investigations.
International GPS Service for Geodynamics
NASA Technical Reports Server (NTRS)
Zumberge, J. F. (Editor); Urban, M. P. (Editor); Liu, R. (Editor); Neilan, R. E. (Editor)
1996-01-01
This 1995 annual report of the IGS International GPS (Global Positioning System) Service for Geodynamics - describes the second operational year of the service. It provides the many IGS contributing agencies and the rapidly growing user community with essential information on current organizational and technical matters promoting the IGS standards and products (including organizational framework, data processing strategies, and statistics showing the remarkable expansion of the GPS monitoring network, the improvement of IGS performance, and product quality). It also introduces important practical concepts for network densification by integration of regional stations and the combination of station coordinate solutions. There are groups of articles describing general aspects of the IGS, the Associate Analysis Centers (AACs), Data Centers, and IGS stations.
NASA Astrophysics Data System (ADS)
Pignalberi, A.; Pezzopane, M.; Rizzi, R.; Galkin, I.
2018-01-01
The first part of this paper reviews methods using effective solar indices to update a background ionospheric model focusing on those employing the Kriging method to perform the spatial interpolation. Then, it proposes a method to update the International Reference Ionosphere (IRI) model through the assimilation of data collected by a European ionosonde network. The method, called International Reference Ionosphere UPdate (IRI UP), that can potentially operate in real time, is mathematically described and validated for the period 9-25 March 2015 (a time window including the well-known St. Patrick storm occurred on 17 March), using IRI and IRI Real Time Assimilative Model (IRTAM) models as the reference. It relies on foF2 and M(3000)F2 ionospheric characteristics, recorded routinely by a network of 12 European ionosonde stations, which are used to calculate for each station effective values of IRI indices IG_{12} and R_{12} (identified as IG_{{12{eff}}} and R_{{12{eff}}}); then, starting from this discrete dataset of values, two-dimensional (2D) maps of IG_{{12{eff}}} and R_{{12{eff}}} are generated through the universal Kriging method. Five variogram models are proposed and tested statistically to select the best performer for each effective index. Then, computed maps of IG_{{12{eff}}} and R_{{12{eff}}} are used in the IRI model to synthesize updated values of foF2 and hmF2. To evaluate the ability of the proposed method to reproduce rapid local changes that are common under disturbed conditions, quality metrics are calculated for two test stations whose measurements were not assimilated in IRI UP, Fairford (51.7°N, 1.5°W) and San Vito (40.6°N, 17.8°E), for IRI, IRI UP, and IRTAM models. The proposed method turns out to be very effective under highly disturbed conditions, with significant improvements of the foF2 representation and noticeable improvements of the hmF2 one. Important improvements have been verified also for quiet and moderately disturbed conditions. A visual analysis of foF2 and hmF2 maps highlights the ability of the IRI UP method to catch small-scale changes occurring under disturbed conditions which are not seen by IRI.
NASA Technical Reports Server (NTRS)
1997-01-01
The International GPS (Global Positioning System) Service for Geodynamics (IGS) supports and helps coordinate GPS data production and parameters useful for generating more accurate data products. The IGS has operated a GPS tracking system for several years. It contains more than 100 stations worldwide and has produced a combined GPS ephemeris that has become the standard for geodesists and geophysicists worldwide. IGS data and products are freely available to all, thanks to the cooperation and participation of all the IGS members. This directory provides data on the stations and provides names and contact information with personnel involved with the IGS.
Estimation of satellite position, clock and phase bias corrections
NASA Astrophysics Data System (ADS)
Henkel, Patrick; Psychas, Dimitrios; Günther, Christoph; Hugentobler, Urs
2018-05-01
Precise point positioning with integer ambiguity resolution requires precise knowledge of satellite position, clock and phase bias corrections. In this paper, a method for the estimation of these parameters with a global network of reference stations is presented. The method processes uncombined and undifferenced measurements of an arbitrary number of frequencies such that the obtained satellite position, clock and bias corrections can be used for any type of differenced and/or combined measurements. We perform a clustering of reference stations. The clustering enables a common satellite visibility within each cluster and an efficient fixing of the double difference ambiguities within each cluster. Additionally, the double difference ambiguities between the reference stations of different clusters are fixed. We use an integer decorrelation for ambiguity fixing in dense global networks. The performance of the proposed method is analysed with both simulated Galileo measurements on E1 and E5a and real GPS measurements of the IGS network. We defined 16 clusters and obtained satellite position, clock and phase bias corrections with a precision of better than 2 cm.
NASA Astrophysics Data System (ADS)
Moore, A. W.
2007-12-01
The International GNSS Service (IGS) is a voluntary collaboration of more than 200 worldwide agencies that pool resources to generate precise GPS and GLONASS products. The foundation of the IGS is a global network of 385 permanent, continuous, geodetic-quality stations independently operated by about 100 agencies. The IGS Central Bureau develops minimum functional requirements and operational standards that enable the individual stations' data to be used coherently in global analyses, but the IGS remains vendor neutral, leaving procurement decisions and implementation details to the individual agencies. The IGS network is hence quite heterogeneous in instrumentation, station management strategies, and culture; these diversities bring both strengths and challenges in coordination. This presentation will detail the IGS's approaches, successes, and opportunities for improvement in coordinating and monitoring the collaborative network.
Guyennon, Nicolas; Cerretto, Giancarlo; Tavella, Patrizia; Lahaye, François
2009-08-01
In recent years, many national timing laboratories have installed geodetic Global Positioning System receivers together with their traditional GPS/GLONASS Common View receivers and Two Way Satellite Time and Frequency Transfer equipment. Many of these geodetic receivers operate continuously within the International GNSS Service (IGS), and their data are regularly processed by IGS Analysis Centers. From its global network of over 350 stations and its Analysis Centers, the IGS generates precise combined GPS ephemeredes and station and satellite clock time series referred to the IGS Time Scale. A processing method called Precise Point Positioning (PPP) is in use in the geodetic community allowing precise recovery of GPS antenna position, clock phase, and atmospheric delays by taking advantage of these IGS precise products. Previous assessments, carried out at Istituto Nazionale di Ricerca Metrologica (INRiM; formerly IEN) with a PPP implementation developed at Natural Resources Canada (NRCan), showed PPP clock solutions have better stability over short/medium term than GPS CV and GPS P3 methods and significantly reduce the day-boundary discontinuities when used in multi-day continuous processing, allowing time-limited, campaign-style time-transfer experiments. This paper reports on follow-on work performed at INRiM and NRCan to further characterize and develop the PPP method for time transfer applications, using data from some of the National Metrology Institutes. We develop a processing procedure that takes advantage of the improved stability of the phase-connected multi-day PPP solutions while allowing the generation of continuous clock time series, more applicable to continuous operation/monitoring of timing equipment.
An accurate Kriging-based regional ionospheric model using combined GPS/BeiDou observations
NASA Astrophysics Data System (ADS)
Abdelazeem, Mohamed; Çelik, Rahmi N.; El-Rabbany, Ahmed
2018-01-01
In this study, we propose a regional ionospheric model (RIM) based on both of the GPS-only and the combined GPS/BeiDou observations for single-frequency precise point positioning (SF-PPP) users in Europe. GPS/BeiDou observations from 16 reference stations are processed in the zero-difference mode. A least-squares algorithm is developed to determine the vertical total electron content (VTEC) bi-linear function parameters for a 15-minute time interval. The Kriging interpolation method is used to estimate the VTEC values at a 1 ° × 1 ° grid. The resulting RIMs are validated for PPP applications using GNSS observations from another set of stations. The SF-PPP accuracy and convergence time obtained through the proposed RIMs are computed and compared with those obtained through the international GNSS service global ionospheric maps (IGS-GIM). The results show that the RIMs speed up the convergence time and enhance the overall positioning accuracy in comparison with the IGS-GIM model, particularly the combined GPS/BeiDou-based model.
INEGI's Network of GPS permanent stations in Mexico
NASA Astrophysics Data System (ADS)
Gonzalez Franco, G. A.
2013-05-01
The Active National Geodetic Network administered by INEGI (Instituto Nacional de Estadística y Geografía) is a set of 24 GPS permanent stations in Mexico that was established in 1993 for a national rural cadastral project, its has been mainly used for geodetic surveys through Mexico including international borders, and has been progressing to contribute to national, regional and international reference frames through the delivering of GPS data or coordinate solutions from INEGI Processing Center to SIRGAS and NAREF. Recently GAMIT/GLOBK Processing of permanent stations in Mexico was realized from 2007-2011 to determine station's velocity. Related to natural hazards, a subset of INEGI network contributes to the project Real Time Integrated Atmosferic Water Wapor and TEC from GPS. The GPS network planned evolution consider changing to a GNSS network, adding stations to IGS, maintain the services of the present, and contribute to multidisciplinary geodetic studies through data publicly available.
Consistency of seven different GNSS global ionospheric mapping techniques during one solar cycle
NASA Astrophysics Data System (ADS)
Roma-Dollase, David; Hernández-Pajares, Manuel; Krankowski, Andrzej; Kotulak, Kacper; Ghoddousi-Fard, Reza; Yuan, Yunbin; Li, Zishen; Zhang, Hongping; Shi, Chuang; Wang, Cheng; Feltens, Joachim; Vergados, Panagiotis; Komjathy, Attila; Schaer, Stefan; García-Rigo, Alberto; Gómez-Cama, José M.
2018-06-01
In the context of the International GNSS Service (IGS), several IGS Ionosphere Associated Analysis Centers have developed different techniques to provide global ionospheric maps (GIMs) of vertical total electron content (VTEC) since 1998. In this paper we present a comparison of the performances of all the GIMs created in the frame of IGS. Indeed we compare the classical ones (for the ionospheric analysis centers CODE, ESA/ESOC, JPL and UPC) with the new ones (NRCAN, CAS, WHU). To assess the quality of them in fair and completely independent ways, two assessment methods are used: a direct comparison to altimeter data (VTEC-altimeter) and to the difference of slant total electron content (STEC) observed in independent ground reference stations (dSTEC-GPS). The main conclusion of this study, performed during one solar cycle, is the consistency of the results between so many different GIM techniques and implementations.
The Contribution of the IGS to a Globally Integrated Geodetic Observing System
NASA Astrophysics Data System (ADS)
WEBER, R.
2002-05-01
The dedicated goal of the International GPS Service (IGS) is 'to provide a service to support geodetic and geophysical research activities through GPS data and data products'. To accomplish its mission IGS began routine operations in Jan 1994. Nowadays operations are based on a large number of components like a globally distributed tracking network of about 200 stations, local and regional data centers as well as eight analysis centers. This presentation summarizes the measurement principles of the GPS and GLONASS microwave satellite navigation systems. An overview of current IGS-products will be given and factors limiting the accuracy of these products are discussed. Moreover IGS serves as one of the technique center of the IERS and therefore the delivered products follow designated IERS standards as close as possible. It can be anticipated that the IGS will also play an important role within the framework of an upcoming Globally Integrated Geodetic Observing System. Even today there are a number of scientific crosslinks to other space geodetic techniques and services e.g. to the ILRS in the determination of the geocentre or to the IVS in questions of a temporal and spatial densification of the reference frame. The above-mentioned initiative will strengthen further the cooperation and increase the scientific outcome.
Geocenter Coordinates from a Combined Processing of LEO and Ground-based GPS Observations
NASA Astrophysics Data System (ADS)
Männel, Benjamin; Rothacher, Markus
2017-04-01
The GPS observations provided by the global IGS (International GNSS Service) tracking network play an important role for the realization of a unique terrestrial reference frame that is accurate enough to allow the monitoring of the Earth's system. Combining these ground-based data with GPS observations tracked by high-quality dual-frequency receivers on-board Low Earth Orbiters (LEO) might help to further improve the realization of the terrestrial reference frame and the estimation of the geocenter coordinates, GPS satellite orbits and Earth rotation parameters (ERP). To assess the scope of improvement, we processed a network of 50 globally distributed and stable IGS-stations together with four LEOs (GRACE-A, GRACE-B, OSTM/Jason-2 and GOCE) over a time interval of three years (2010-2012). To ensure fully consistent solutions the zero-difference phase observations of the ground stations and LEOs were processed in a common least-square adjustment, estimating GPS orbits, LEO orbits, station coordinates, ERPs, site-specific tropospheric delays, satellite and receiver clocks and ambiguities. We present the significant impact of the individual LEOs and a combination of all four LEOs on geocenter coordinates derived by using a translational approach (also called network shift approach). In addition, we present geocenter coordinates derived from the same set of GPS observations by using a unified approach. This approach combines the translational and the degree-one approach by estimating translations and surface deformations simultaneously. Based on comparisons against each other and against geocenter time series derived by other techniques the effect of the selected approach is assessed.
NASA Astrophysics Data System (ADS)
Alizadeh, M.; Schuh, H.; Schmidt, M. G.
2012-12-01
In the last decades Global Navigation Satellite System (GNSS) has turned into a promising tool for probing the ionosphere. The classical input data for developing Global Ionosphere Maps (GIM) is obtained from the dual-frequency GNSS observations. Simultaneous observations of GNSS code or carrier phase at each frequency is used to form a geometric-free linear combination which contains only the ionospheric refraction term and the differential inter-frequency hardware delays. To relate the ionospheric observable to the electron density, a model is used that represents an altitude-dependent distribution of the electron density. This study aims at developing a global multi-dimensional model of the electron density using simulated GNSS observations from about 150 International GNSS Service (IGS) ground stations. Due to the fact that IGS stations are in-homogenously distributed around the world and the accuracy and reliability of the developed models are considerably lower in the area not well covered with IGS ground stations, the International Reference Ionosphere (IRI) model has been used as a background model. The correction term is estimated by applying spherical harmonics expansion to the GNSS ionospheric observable. Within this study this observable is related to the electron density using different functions for the bottom-side and top-side ionosphere. The bottom-side ionosphere is represented by an alpha-Chapman function and the top-side ionosphere is represented using the newly proposed Vary-Chap function.aximum electron density, IRI background model (elec/m3), day 202 - 2010, 0 UT eight of maximum electron density, IRI background model (km), day 202 - 2010, 0 UT
PPP Sliding Window Algorithm and Its Application in Deformation Monitoring.
Song, Weiwei; Zhang, Rui; Yao, Yibin; Liu, Yanyan; Hu, Yuming
2016-05-31
Compared with the double-difference relative positioning method, the precise point positioning (PPP) algorithm can avoid the selection of a static reference station and directly measure the three-dimensional position changes at the observation site and exhibit superiority in a variety of deformation monitoring applications. However, because of the influence of various observing errors, the accuracy of PPP is generally at the cm-dm level, which cannot meet the requirements needed for high precision deformation monitoring. For most of the monitoring applications, the observation stations maintain stationary, which can be provided as a priori constraint information. In this paper, a new PPP algorithm based on a sliding window was proposed to improve the positioning accuracy. Firstly, data from IGS tracking station was processed using both traditional and new PPP algorithm; the results showed that the new algorithm can effectively improve positioning accuracy, especially for the elevation direction. Then, an earthquake simulation platform was used to simulate an earthquake event; the results illustrated that the new algorithm can effectively detect the vibrations change of a reference station during an earthquake. At last, the observed Wenchuan earthquake experimental results showed that the new algorithm was feasible to monitor the real earthquakes and provide early-warning alerts.
Integrity monitoring of IGS products
NASA Technical Reports Server (NTRS)
Zumberge, James F.; Plag, H. -P.
2005-01-01
The IGS has successfully produced precise GPS and GLONASS transmitter parameters, coordinates of IGS tracking stations, Earth rotation parameters, and atmospheric parameters. In this paper we discuss the concepts of integrity monitoring, system monitoring, and performance assessment, all in the context of IGS products. We report on a recent survey of IGS product users, and propose an integrity strategy for the IGS.
A Contribution For The Understanding of The Deformation Pattern Across The Terceira Axis
NASA Astrophysics Data System (ADS)
Navarro, A.; Catalão, J.; Miranda, J. M.
In spite of several geodynamics studies performed in the Azores region, little is known about the deformation pattern of the tectonically more active sector around the Ter- ceira Axis. GPS campaigns performed in the area, in the last few years, were mainly concerned to the study of the relative motions between the Eurasian, African and North-American plates. This study, developed in the scope of the STAMINA project, has as main purpose the establishment of a dense GPS network to study the crustal deformation pattern in the area between the North Hirondelle basin and the East Gra- ciosa basin. The GPS network consists of 20 stations uniformly distributed throughout the island. The first GPS survey was carried out during days 90 to 98 of 2001. TERC and TCAT stations were used as reference stations, recording continuously throughout the survey. All the other stations were occupied for at least three sessions, except for cases of receiver malfunction, each session has a duration of 12 to 24 hours. The GPS data processing approach consisted of three main steps: (1) first, all sessions were processed separately using GAMIT in order to obtain a daily solution for two local sites (TERC and TCAT) and six global tracking stations (CCV3, RABT, SAV1, SFER, STJO and WSRT) using precise orbits from the IGS; (2) then, all stations of the local network are processed together and (3) finally, all station, including the global tracking ones, are reprocessed again. Precise orbits from the IGS were used in the processing. In each step a compensation program was used to compute a least squares network adjusted solution for the campaign, where all sessions are combined to yield estimates of improved station coordinates. The final solution achieved with the described methodology is documented in this paper. Further geodetic observations are needed in order to estimate the stations ve- locities and displacements and consequently to determine the rate of deformation of the island.
Geocenter variations derived from a combined processing of LEO- and ground-based GPS observations
NASA Astrophysics Data System (ADS)
Männel, Benjamin; Rothacher, Markus
2017-08-01
GNSS observations provided by the global tracking network of the International GNSS Service (IGS, Dow et al. in J Geod 83(3):191-198, 2009) play an important role in the realization of a unique terrestrial reference frame that is accurate enough to allow a detailed monitoring of the Earth's system. Combining these ground-based data with GPS observations tracked by high-quality dual-frequency receivers on-board low earth orbiters (LEOs) is a promising way to further improve the realization of the terrestrial reference frame and the estimation of geocenter coordinates, GPS satellite orbits and Earth rotation parameters. To assess the scope of the improvement on the geocenter coordinates, we processed a network of 53 globally distributed and stable IGS stations together with four LEOs (GRACE-A, GRACE-B, OSTM/Jason-2 and GOCE) over a time interval of 3 years (2010-2012). To ensure fully consistent solutions, the zero-difference phase observations of the ground stations and LEOs were processed in a common least-squares adjustment, estimating all the relevant parameters such as GPS and LEO orbits, station coordinates, Earth rotation parameters and geocenter motion. We present the significant impact of the individual LEO and a combination of all four LEOs on the geocenter coordinates. The formal errors are reduced by around 20% due to the inclusion of one LEO into the ground-only solution, while in a solution with four LEOs LEO-specific characteristics are significantly reduced. We compare the derived geocenter coordinates w.r.t. LAGEOS results and external solutions based on GPS and SLR data. We found good agreement in the amplitudes of all components; however, the phases in x- and z-direction do not agree well.
NASA Astrophysics Data System (ADS)
Szafranek, K.; Schillak, S.; Araszkiewicz, A.; Figurski, M.; Lehmann, M.; Lejba, P.
2012-04-01
Up-to-date investigations concerning space geodesy are mostly aimed at data of various techniques joint processing. The poster presents solutions (North, East, Up components) of selected stations (McDonald, Yarragadee, Greenbelt, Monument Peak, Zimmerwald, Borowiec, Mt.Stromlo-Orroral, Potsdam, Graz, Herstmonceux and Wettzell), which adopted Satellite Laser Ranging (SLR) and Global Navigation Satellite System (GNSS) techniques and which were gathering the data in the same time (from 1994 to 2010). Processing of both types of data was made according to Global Geodetic Observing System (GGOS) recommendations, the same models and parameters from IERS Conventions 2010 were used in both processing strategies (if it was possible). The main goal was to obtain coordinates and their changes in time (velocities) basing on both techniques and to compare the results. The station coordinates were determined for the common reference epoch of both techniques - for first day of each month. Monthly orbital arcs for laser observations were created basing on solutions from several SLR sites (observations to LAGEOS-1 and LAGEOS-2 satellites) with the best solutions quality and the highest amount of observations. For GNSS coordinates determination about 130 sites belonging to International GNSS Service (IGS) were selected: 30 with local ties to SLR sites and others basing on their geolocalization (length of the baselines) and solutions time series analysis. Mainly, core IGS stations were used. Solutions of both techniques were analyzed in order to verify agreement of both techniques and for independent control of local ties.
NASA Astrophysics Data System (ADS)
Alothman, Abdulaziz; Ayhan, Mehmet
In the 21st century, sea level rise is expected to be about 30 cm or even more (up to 60 cm). Saudi Arabia has very long coasts of about 3400 km and hundreds of islands. Therefore, sea level monitoring may be important in particular along coastal low lands on Red Sea and Arabian Gulf coasts. Arabian Gulf is connected to Indian Ocean and lying along a parallel course in the south-west of the Zagros Trust Belt. We expect vertical land motion within the area due to both tectonic structures of the Arabian Peninsula and oil production activities. Global Navigation Satellite System (GNSS) Continues observations were used to estimate the vertical crustal motion. Bahrain International GPS Service (IGS-GPS) station is the only continuous GPS station accessible in the region, and it is close to the Mina Sulman tide gauge station in Bahrain. The weekly GPS time series of vertical component at Bahrain IGS-GPS station referring to the ITRF97 from 1999.2 to 2008.6 are used in the computation. We fitted a linear trend with an annual signal and a break to the GPS vertical time series and found a vertical land motion rate of 0.46 0.11 mm/yr. To investigate sea level variation within the west of Arabian Gulf, monthly means of sea level at 13 tide gauges along the coast of Saudi Arabia and Bahrain, available in the database of the Permanent Service for Mean Sea Level (PSMSL), are studied. We analyzed separately the monthly mean sea level measurements at each station, and estimated secular sea level rate by a robust linear trend fitting. We computed the average relative sea level rise rate of 1.96 0.21 mm/yr within the west of Arabian Gulf based on 4 stations spanning longer than 19 years. Sea level rates at the stations are first corrected for vertical land motion contamination using the ICE-5G v1.2 VM4 Glacial Isostatic Adjustment (GIA) model, and the average sea level rate is found 2.27 0.21 mm/yr. Assuming the vertical rate at Bahrain IGS-GPS station represents the vertical rate at each of the other tide gauge stations studied here in the region, we computed average sea level rise rate of 2.42 0.21 mm/yr within the west of Arabian Gulf.
IGS Network Coordinator Report - 2002
NASA Technical Reports Server (NTRS)
Moore, Angelyn
2004-01-01
The IGS network is a set of permanent, continuously-operating, dual-frequency GPS stations operated by over 100 worldwide agencies. The dataset is pooled at IGS Data Centers for routine use by IGS Analysis Centers in creating precise IGS products, as well as free access by other analysts around the world. The IGS Central Bureau hosts the IGS Network Coordinator, who assures adherence to standards and provides information regarding the IGS network via the Central Bureau Information System website at http://igscb.jpl.nasa.gov.
Goddard Geophysical and Astronomical Observatory
NASA Technical Reports Server (NTRS)
Figueroa, Ricardo
2013-01-01
This report summarizes the technical parameters and the technical staff of the VLBI system at the fundamental station GGAO. It also gives an overview about the VLBI activities during the report year. The Goddard Geophysical and Astronomical Observatory (GGAO) consists of a 5-meter radio telescope for VLBI, a new 12-meter radio telescope for VLBI2010 development, a 1-meter reference antenna for microwave holography development, an SLR site that includes MOBLAS-7, the NGSLR development system, and a 48" telescope for developmental two-color Satellite Laser Ranging, a GPS timing and development lab, a DORIS system, meteorological sensors, and a hydrogen maser. In addition, we are a fiducial IGS site with several IGS/IGSX receivers. GGAO is located on the east coast of the United States in Maryland. It is approximately 15 miles NNE of Washington, D.C. in Greenbelt, Maryland.
Rigidity of Major Plates and Microplates Estimated From GPS Solution GPS2006.0
NASA Astrophysics Data System (ADS)
Kogan, M. G.; Steblov, G. M.
2006-05-01
Here we analyze the rigidity of eight major lithospheric plates using our global GPS solution GPS2006.0. We included all daily observations in interval 1995.0 to 2006.0 collected at IGS stations, as well as observations at many important stations not included in IGS. Loose multiyear solution GPS2006.0 is based on daily solutions by GAMIT software, performed at SOPAC and at Columbia University; those daily solutions were combined by Kalman filter (GLOBK software) into a loose multiyear solution. The constrained solution for station positions and velocities was obtained without a conventional reference frame; instead, we applied translation and rotation in order to best fit the zero velocities of 76 stations in stable plate cores excluding the regions of postglacial rebound. Simultaneously, we estimated relative plate rotation vectors (RV) and the origin translation rate (OTR), and then corrected station velocities for it. Therefore, the velocities in GPS2006.0 are unaffected by the OTR error of ITRF2000 conventionally used to constrain a loose solution. The 1-sigma plate-residual velocity in a stable plate core is less than 1 mm/yr for the plates: Eurasia, Pacific, North and South Americas, Nubia, Australia, and Antarctica; it is 1.4 mm/yr for the Indian plate, most probably because of poorer data quality. Plate-residuals at other established plates (Arabia, Nazca, Caribbean, Philippine) were not assessed for lack of observations. From our analysis, an upper bound for the mobility of the plate inner area is 1 mm/yr. Plate- residual GPS velocities for several hypothesized microplates in east Asia, such as Okhotsk, Amuria, South China, are 3-4 times higher; corresponding strain rates for these microplates are an order of magnitude higher than for Eurasia, North America, and other large plates.
NASA Astrophysics Data System (ADS)
Rabah, Mostafa; Elmewafey, Mahmoud; Farahan, Magda H.
2016-06-01
A geodetic control network is the wire-frame or the skeleton on which continuous and consistent mapping, Geographic Information Systems (GIS), and surveys are based. Traditionally, geodetic control points are established as permanent physical monuments placed in the ground and precisely marked, located, and documented. With the development of satellite surveying methods and their availability and high degree of accuracy, a geodetic control network could be established by using GNSS and referred to an international terrestrial reference frame used as a three-dimensional geocentric reference system for a country. Based on this concept, in 1992, the Egypt Survey Authority (ESA) established two networks, namely High Accuracy Reference Network (HARN) and the National Agricultural Cadastral Network (NACN). To transfer the International Terrestrial Reference Frame to the HARN, the HARN was connected with four IGS stations. The processing results were 1:10,000,000 (Order A) for HARN and 1:1,000,000 (Order B) for NACN relative network accuracy standard between stations defined in ITRF1994 Epoch1996. Since 1996, ESA did not perform any updating or maintaining works for these networks. To see how non-performing maintenance degrading the values of the HARN and NACN, the available HARN and NACN stations in the Nile Delta were observed. The Processing of the tested part was done by CSRS-PPP Service based on utilizing Precise Point Positioning "PPP" and Trimble Business Center "TBC". The study shows the feasibility of Precise Point Positioning in updating the absolute positioning of the HARN network and its role in updating the reference frame (ITRF). The study also confirmed the necessity of the absent role of datum maintenance of Egypt networks.
Specific Immunoglobulin (Ig) G Reference Intervals for Common Food, Insect, and Mold Allergens.
Martins, Thomas B; Bandhauer, Michael E; Wilcock, Diane M; Hill, Harry R; Slev, Patricia R
2016-12-01
The clinical utility of serum IgG measurement in the diagnosis of allergy and food-induced hypersensitivity has been largely discredited. Recent studies, however, have shown that specific IgG can inhibit IgE mediated allergies, and may play a role in allergen specific desensitization. Accurate reference intervals for IgG specific allergens have not been widely established and are needed for better interpretation of serum antibody concentrations. In this study we established 64 IgG reference intervals for 48 common food allergens, 5 venoms, and 11 molds. Specific IgG concentrations were determined employing an automated fluorescent enzyme immunoassay on serum samples from 130 normal adults (65 males and 65 females), age range 18-69 y, mean 37.3 y. The lower reference interval limit for all allergens tested (n=64) was <2 mcg/mL. The median upper reference interval value for all 64 allergens was 12.9 mcg/mL, with Tuna (f40) having the lowest upper interval limit at 3.8 mcg/mL, and the mold Setomelanomma rostrate (m8) demonstrating the highest upper interval limit at 131 mcg/L. The considerable variation observed among the upper reference interval limits emphasizes the need for the establishment of allergen specific ranges for IgG. These newly established ranges should be a useful aid for clinicians in the interpretation of laboratory serum IgG results. © 2016 by the Association of Clinical Scientists, Inc.
High Frequency Fluctuations of Polar Motion During IGS'92 Campaign
NASA Astrophysics Data System (ADS)
Huang, Chengli; Jin, Wenjin; Liao, Dechun; Zhu, Wenyao; Wang, Jiexian
1994-09-01
During IGS'92 Campaign seven PM(Polar Motion) series provided by GPS Processing Centers are analysed in this paper. Some similar high frequency fluctuations in these PM series are detected by using spectra! analyses, least square adjustment and F-test as follows: there are short periodic fluctuations of 27.0, 16.5, 13.4, 10.4 day in X direction; and of 10.0, 20.5, 15.8 day in Y direction. And there are similar systematic deviations derived from the comparison of each series with EOP(IERS) 92 C 04. The inain cause of these systematic deviations is that the rotation between the reference frames of these series and ITRF91 exists. As for the reason, the coordinates of stations are not fixed (or partly fixed only) when solving X and Y with GPS data. The high frequency fluctuations of polar motion are explained to some extent by the excitation of atmospheric angular momentum.
Ubillos, Itziar; Jiménez, Alfons; Vidal, Marta; Bowyer, Paul W; Gaur, Deepak; Dutta, Sheetij; Gamain, Benoit; Coppel, Ross; Chauhan, Virander; Lanar, David; Chitnis, Chetan; Angov, Evelina; Beeson, James; Cavanagh, David; Campo, Joseph J; Aguilar, Ruth; Dobaño, Carlota
2018-06-01
The quantitative suspension array technology (qSAT) is a useful platform for malaria immune marker discovery. However, a major challenge for large sero-epidemiological and malaria vaccine studies is the comparability across laboratories, which requires the access to standardized control reagents for assay optimization, to monitor performance and improve reproducibility. Here, the Plasmodium falciparum antibody reactivities of the newly available WHO reference reagent for anti-malaria human plasma (10/198) and of additional customized positive controls were examined with seven in-house qSAT multiplex assays measuring IgG, IgG 1-4 subclasses, IgM and IgE against a panel of 40 antigens. The different positive controls were tested at different incubation times and temperatures (4 °C overnight, 37 °C 2 h, room temperature 1 h) to select the optimal conditions. Overall, the WHO reference reagent had low IgG2, IgG4, IgM and IgE, and also low anti-CSP antibody levels, thus this reagent was enriched with plasmas from RTS,S-vaccinated volunteers to be used as standard for CSP-based vaccine studies. For the IgM assay, another customized plasma pool prepared with samples from malaria primo-infected adults with adequate IgM levels proved to be more adequate as a positive control. The range and magnitude of IgG and IgG 1-4 responses were highest when the WHO reference reagent was incubated with antigen-coupled beads at 4 °C overnight. IgG levels measured in the negative control did not vary between incubations at 37 °C 2 h and 4 °C overnight, indicating no difference in unspecific binding. With this study, the immunogenicity profile of the WHO reference reagent, including seven immunoglobulin isotypes and subclasses, and more P. falciparum antigens, also those included in the leading RTS,S malaria vaccine, was better characterized. Overall, incubation of samples at 4 °C overnight rendered the best performance for antibody measurements against the antigens tested. Although the WHO reference reagent performed well to measure IgG to the majority of the common P. falciparum blood stage antigens tested, customized pools may need to be used as positive controls depending on the antigens (e.g. pre-erythrocytic proteins of low natural immunogenicity) and isotypes/subclasses (e.g. IgM) under study.
Parker, Antony; Irure Ventura, Juan; Sims, Dawn; Echeverría de Carlos, Ainara; Gómez de la Torre, Ricardo; Tricas Aizpún, Lourdes; Ocejo-Vinyals, J Gonzalo; López-Hoyos, Marcos; Wallis, Gregg; Harding, Stephen
2017-01-01
IgG2 is the most efficient subclass for providing protection against pneumococcal pathogens. We hypothesised that some individuals may be unable to mount an effective pneumococcal capsular polysaccharide (PCP) IgG2 response despite having a normal PCP IgG concentration (PCP IgG2 deficient). The median pre-vaccination PCP IgG2 concentration was significantly lower in individuals referred for immunological investigation compared to healthy controls (2.8 mg/L range, 95% CI 1.1-88 vs. 29.5mg/L, 95% CI 13.5-90, p = 0.0002). PCP IgG:IgG2 ratios were significantly higher for the referral population than for healthy controls suggesting the increased production of PCP specific subclasses other than IgG2. The percentage of individuals with PCP IgG2 deficiency was significantly higher in referral groups compared to controls (31% vs. 5%; p = 0.0009) and in an individual with PCP IgG2 deficiency, the balance of PCP specific IgG subclass antibodies post vaccination changed from IgG2>IgG1>IgG3>IgG4 to IgG1>IgG3>IgG2>IgG4. The median PCP IgG2 concentration in those with PCP IgG2 deficiency was significantly lower in the referral groups compared to controls (7.8 mg/L, 95% CI 1.1-12 vs. 12.7 mg/L, 95% CI 11.8-13.1; p = 0.006). The data suggests a defect in the production PCP IgG2 may be present in individuals with normal PCP IgG referred for immunological investigation.
Riffelmann, M.; Thiel, K.; Schmetz, J.; Wirsing von Koenig, C. H.
2010-01-01
Measuring antibodies to Bordetella pertussis antigens is mostly done by enzyme-linked immunosorbent assays (ELISAs). We compared the performance of ELISA kits that were commercially available in Germany. Eleven measured IgG antibodies, and nine measured IgA antibodies. An in-house ELISA with purified antigens served as a reference method. Samples included two WHO reference preparations, the former Food and Drug Administration (FDA)/Center for Biologics Evaluation and Research (CBER) reference preparations, serum samples from patients with clinically suspected pertussis, and serum samples from patients having received a combined tetanus, diphtheria, and pertussis (Tdap) vaccination. Kits using pertussis toxin (PT) as an antigen showed linearity compared to the WHO Reference preparation (r2 between 0.82 and 0.99), and these kits could quantify antibodies according to the reference preparation. ELISA kits using mixed antigens showed no linear correlation to the reference preparations. Patient results were compared to results of in-house ELISAs using a dual cutoff of either ≥100 IU/ml anti-PT IgG or ≥40 IU/ml anti-PT IgG together with ≥12 IU/ml anti-PT IgA. The sensitivities of kits measuring IgG antibodies ranged between 0.84 and 1.00. The specificities of kits using PT as an antigen were between 0.81 and 0.93. The specificities of kits using mixed antigens were between 0.51 and 0.59 and were thus not acceptable. The sensitivities of kits measuring IgA antibodies ranged between 0.53 and 0.73, and the specificities were between 0.67 and 0.94, indicating that IgA antibodies may be of limited diagnostic value. Our data suggest that ELISAs should use purified PT as an antigen and be standardized to the 1st International Reference preparation. PMID:20943873
The Terceira island (Azores) crustal deformations from GPS data
NASA Astrophysics Data System (ADS)
Navarro, A.; Catalão, J.; Fernandes, R.; Miranda, M.; Bastos, L.
2003-04-01
Several GPS campaigns performed, for the last few years, in the Azores region have proved the utility of GPS data in the evaluation of the relative motion among the Eurasian, North-American and African plates. The study here presented was developed in the scope of the STAMINA project. This project main intention is the study of the deformation pattern of the area along the Terceira Axis, which is considered nowadays as the most active tectonic area of the Azores region. To achieve that, a dense GPS network was implemented on the Terceira Island in October 2000. The network has 23 stations spread uniformly throughout the island, ten of which had already been implemented on 1999 (1 in 1988) in the scope of the TANGO project. These 10 stations were observed for the first time in 1999 and re-observed in 2000 and 2001. The complete network was observed for the first time in March/April of 2001. GPS data from 2 epochs, 1999 and 2001, were used to evaluate the horizontal deformation of the Island for a period of one and a half year. Both campaigns last for 9 days, each station being observed for at least 3 sessions of 12 to 24 hours. One of the stations, located at the Terceira Astronomic Observatory (TERC), was continuously measured during both campaigns. The data processing was performed using the GAMIT and FONDA software. Data from six IGS/EUREF permanent stations were considered to link the local network to the ITRF97 reference system. Precise orbits from the IGS were used in the GPS data processing. The results exhibit repeatabilities of about 3 mm and 2 mm for both components of the horizontal position, respectively for 1999 and 2001. The resulting estimation of the main strain rates for the Island indicates N, NNE and NE directions for the extension of the Island. However, these results are not yet conclusive due to the poor geometry of the 10 stations network and to the short interval of observation. To establish a more reliable deformation pattern for the Island, the 23 stations network are intended to be re-observed during 2003.
IGS preparations for the next reprocessing and ITRF
NASA Astrophysics Data System (ADS)
Griffiths, J.; Rebischung, P.; Garayt, B.; Ray, J.
2012-04-01
The International GNSS Service (IGS) is preparing for a second reanalysis of the full history of data collected by the global network using the latest models and methodologies. This effort is designed to obtain improved, consistent satellite orbits, station and satellite clocks, Earth orientation parameters (EOPs) and terrestrial frame products using the current IGS framework, IGS08/igs08.atx. It follows a successful first reprocessing campaign, which provided the IGS input to ITRF2008. Likewise, this second campaign (repro2) should provide the IGS contribution to the next ITRF. We will discuss the analysis standards adopted for repro2, including treatment of and mitigation against non-tidal loading effects, and improvements expected with respect to the first reprocessing campaign. International Earth Rotation and Reference Systems Service (IERS) Conventions of 2010 are expected to be implemented. Though, no improvements in the diurnal and semidiurnal EOP tide models will be made, so associated errors will remain. Adoption of new orbital force models and consistent handling of satellite attitude changes are expected to improve IGS clock and orbit products. A priori Earth-reflected radiation pressure models should nearly eliminate the ~2.5 cm orbit radial bias previously observed using laser ranging methods. Also, a priori modeling of radiation forces exerted in signal transmission should improve the orbit products. And use of consistent satellite attitude models should help with satellite clock estimation during Earth and Moon eclipses. Improvements of the terrestrial frame products are expected from, for example, the inclusion of second order ionospheric corrections and also the a priori modeling of Earth-reflected radiation pressure. Because of remaining unmodeled orbital forces, systematic errors will however likely continue to affect the origin of the repro2 frames and prevent a contribution of GNSS to the origin of the next ITRF. On the other hand, the planned inclusion of satellite phase center offsets in the long-term stacking of the repro2 frames could help in defining the scale rate of the next ITRF.
A New Global Vertical Land Movement Data Set from the TIGA Combined Solution
NASA Astrophysics Data System (ADS)
Hunegnaw, Addisu; Teferle, Felix Norman; Ebuy Abraha, Kibrom; Santamaría-Gómez, Alvaro; Gravelle, Médéric; Wöppelman, Guy; Schöne, Tilo; Deng, Zhiguo; Bingley, Richard; Hansen, Dionne Nicole; Sanchez, Laura; Moore, Michael; Jia, Minghai
2017-04-01
Globally averaged sea level has been estimated from the network of tide gauges installed around the world since the 19th century. These mean sea level (MSL) records provide sea level relative to a nearby tide gauge benchmark (TGBM), which allows for the continuation of the instrumental record in time. Any changes in the benchmark levels, induced by vertical land movements (VLM) affect the MSL records and hence sea level estimates. Over the last two decades sea level has also been observed using satellite altimeters. While the satellite observations are globally more homogeneous providing a picture of sea level not confined to coastlines, they require the VLM-corrected MSL records for the bias calibration of instrumental drifts. Without this calibration altimeter instruments from different missions cannot be combined. GPS has made it possible to obtain highly accurate estimates of VLM in a geocentric reference frame for stations at or close to tide gauges. Under the umbrella of the International GNSS Service (IGS), the Tide Gauge Benchmark Monitoring (TIGA) Working Group (WG) has been established to apply the expertise of the GNSS community to solving issues related to the accuracy and reliability of the vertical component to provide estimates of VLM in a well-defined global reference frame. To achieve this objective, five TIGA Analysis Centers (TACs) contributed re-processed global GPS network solutions to TIGA, employing the latest bias models and processing strategies in accordance with the second re-processing campaign (repro2) of the IGS. These solutions include those of the British Isles continuous GNSS Facility - University of Luxembourg consortium (BLT), the German Research Centre for Geosciences (GFZ) Potsdam, the German Geodetic Research Institute (DGF) at the Technical University of Munich, Geoscience Australia (AUT) and the University of La Rochelle (ULR). In this study we present to the sea level community an evaluation of the VLM estimates from the first combined solution from the IGS TIGA WG. The TAC solutions include more than 700 stations and span the common period 1995-2014. The combined solution was computed by the TIGA Combination Centre (TCC) at the University of Luxembourg, which used the Combination and Analysis of Terrestrial Reference Frame (CATREF) software package for this purpose. This first solution forms Release 1.0 and further releases will be made available after further reprocessing campaigns. We evaluate the combined solution internally using the TAC solutions and externally using solutions from the IGS and the ITRF2008. The derived VLM estimates have undergone an initial evaluation and should be considered as the primary TIGA product for the sea level community to correct MSL records for land level changes.
Real Time GPS- Satellite Clock Estimation Development of a RTIGS Web Service
NASA Astrophysics Data System (ADS)
Opitz, M.; Weber, R.; Caissy, M.
2006-12-01
Since 3 years the IGS (International GNSS Service) Real-Time Working Group disseminates via Internet raw observation data of a subset of stations of the IGS network. This observation data can be used to establish a real-time integrity monitoring of the IGS predicted orbits (Ultra Rapid (IGU-) Orbits) and clocks, according to the recommendations of the IGS Workshop 2004 in Bern. The Institute for "Geodesy and Geophysics" of the TU-Vienna develops in cooperation with the IGS Real-Time Working Group the software "RTR- Control", which currently provides a real-time integrity monitoring of predicted IGU Clock Corrections to GPS Time. Our poster presents the results of a prototype version which is in operation since August this year. Besides RTR-Control allows for the comparison of pseudoranges measured at any permanent station in the global network with theoretical pseudoranges calculated on basis of the IGU- orbits. Thus, the programme can diagnose incorrectly predicted satellite orbits and clocks as well as detect multi-path distorted pseudoranges in real- time. RTR- Control calculates every 15 seconds Satellite Clock Corrections with respect to the most recent IGU- clocks (updated in a 6 hours interval). The clock estimations are referenced to a stable station clock (H-maser) with a small offset to GPS- time. This real-time Satellite Clocks are corrected for individual outliers and modelling errors. The most recent GPS- Satellite Clock Corrections (updated every 60 seconds) are published in Real Time via the Internet. The user group interested in a rigorous integrity monitoring comprises on the one hand the components of IGS itself to qualify the issued orbital data and on the other hand all users of the IGS Ultra Rapid Products (e.g. for PPP in Real Time).
Application of thin plate splines for accurate regional ionosphere modeling with multi-GNSS data
NASA Astrophysics Data System (ADS)
Krypiak-Gregorczyk, Anna; Wielgosz, Pawel; Borkowski, Andrzej
2016-04-01
GNSS-derived regional ionosphere models are widely used in both precise positioning, ionosphere and space weather studies. However, their accuracy is often not sufficient to support precise positioning, RTK in particular. In this paper, we presented new approach that uses solely carrier phase multi-GNSS observables and thin plate splines (TPS) for accurate ionospheric TEC modeling. TPS is a closed solution of a variational problem minimizing both the sum of squared second derivatives of a smoothing function and the deviation between data points and this function. This approach is used in UWM-rt1 regional ionosphere model developed at UWM in Olsztyn. The model allows for providing ionospheric TEC maps with high spatial and temporal resolutions - 0.2x0.2 degrees and 2.5 minutes, respectively. For TEC estimation, EPN and EUPOS reference station data is used. The maps are available with delay of 15-60 minutes. In this paper we compare the performance of UWM-rt1 model with IGS global and CODE regional ionosphere maps during ionospheric storm that took place on March 17th, 2015. During this storm, the TEC level over Europe doubled comparing to earlier quiet days. The performance of the UWM-rt1 model was validated by (a) comparison to reference double-differenced ionospheric corrections over selected baselines, and (b) analysis of post-fit residuals to calibrated carrier phase geometry-free observational arcs at selected test stations. The results show a very good performance of UWM-rt1 model. The obtained post-fit residuals in case of UWM maps are lower by one order of magnitude comparing to IGS maps. The accuracy of UWM-rt1 -derived TEC maps is estimated at 0.5 TECU. This may be directly translated to the user positioning domain.
NASA Astrophysics Data System (ADS)
Phillips, D. A.; Herring, T.; Melbourne, T. I.; Murray, M. H.; Szeliga, W. M.; Floyd, M.; Puskas, C. M.; King, R. W.; Boler, F. M.; Meertens, C. M.; Mattioli, G. S.
2017-12-01
The Geodesy Advancing Geosciences and EarthScope (GAGE) Facility, operated by UNAVCO, provides a diverse suite of geodetic data, derived products and cyberinfrastructure services to support community Earth science research and education. GPS data and products including decadal station position time series and velocities are provided for 2000+ continuous GPS stations from the Plate Boundary Observatory (PBO) and other networks distributed throughout the high Arctic, North America, and Caribbean regions. The position time series contain a multitude of signals in addition to the secular motions, including coseismic and postseismic displacements, interseismic strain accumulation, and transient signals associated with hydrologic and other processes. We present our latest velocity field solutions, new time series offset estimate products, and new time series examples associated with various phenomena. Position time series, and the signals they contain, are inherently dependent upon analysis parameters such as network scaling and reference frame realization. The estimation of scale changes for example, a common practice, has large impacts on vertical motion estimates. GAGE/PBO velocities and time series are currently provided in IGS (IGb08) and North America (NAM08, IGb08 rotated to a fixed North America Plate) reference frames. We are reprocessing all data (1996 to present) as part of the transition from IGb08 to IGS14 that began in 2017. New NAM14 and IGS14 data products are discussed. GAGE/PBO GPS data products are currently generated using onsite computing clusters. As part of an NSF funded EarthCube Building Blocks project called "Deploying MultiFacility Cyberinfrastructure in Commercial and Private Cloud-based Systems (GeoSciCloud)", we are investigating performance, cost, and efficiency differences between local computing resources and cloud based resources. Test environments include a commercial cloud provider (Amazon/AWS), NSF cloud-like infrastructures within XSEDE (TACC, the Texas Advanced Computing Center), and in-house cyberinfrastructures. Preliminary findings from this effort are presented. Web services developed by UNAVCO to facilitate the discovery, customization and dissemination of GPS data and products are also presented.
Implementation and testing of the gridded Vienna Mapping Function 1 (VMF1)
NASA Astrophysics Data System (ADS)
Kouba, J.
2008-04-01
The new gridded Vienna Mapping Function (VMF1) was implemented and compared to the well-established site-dependent VMF1, directly and by using precise point positioning (PPP) with International GNSS Service (IGS) Final orbits/clocks for a 1.5-year GPS data set of 11 globally distributed IGS stations. The gridded VMF1 data can be interpolated for any location and for any time after 1994, whereas the site-dependent VMF1 data are only available at selected IGS stations and only after 2004. Both gridded and site-dependent VMF1 PPP solutions agree within 1 and 2 mm for the horizontal and vertical position components, respectively, provided that respective VMF1 hydrostatic zenith path delays (ZPD) are used for hydrostatic ZPD mapping to slant delays. The total ZPD of the gridded and site-dependent VMF1 data agree with PPP ZPD solutions with RMS of 1.5 and 1.8 cm, respectively. Such precise total ZPDs could provide useful initial a priori ZPD estimates for kinematic PPP and regional static GPS solutions. The hydrostatic ZPDs of the gridded VMF1 compare with the site-dependent VMF1 ZPDs with RMS of 0.3 cm, subject to some biases and discontinuities of up to 4 cm, which are likely due to different strategies used in the generation of the site-dependent VMF1 data. The precision of gridded hydrostatic ZPD should be sufficient for accurate a priori hydrostatic ZPD mapping in all precise GPS and very long baseline interferometry (VLBI) solutions. Conversely, precise and globally distributed geodetic solutions of total ZPDs, which need to be linked to VLBI to control biases and stability, should also provide a consistent and stable reference frame for long-term and state-of-the-art numerical weather modeling.
NASA Astrophysics Data System (ADS)
Gulyaeva, T. L.; Arikan, F.; Sezen, U.; Poustovalova, L. V.
2018-07-01
In view of the recent recalibration of the sunspot number time series SSN2, a need has arisen to re-evaluate solar and ionospheric indices in the International Reference Ionosphere, IRI, and its extension to the Plasmasphere, IRI-Plas models, which are developed using the predecessor SSN1 index. To improve efficiency of the model, eight solar proxy indices are introduced in IRI-Plas system: the daily measured solar emissions, the Ottawa 10.7-cm radio flux F10.7 and the H Lyman-α line at 121.6 nm; the core-to-wing ratio of the magnesium ion h and k lines at 279.56 and 280.27 nm, MgII index; sunspot number SSN1 observed before 05.2015 and modelled afterwards; re-calibrated SSN2 sunspots time series; the ionosonde foF2-based global IG-index and the Global Electron Content, GEC, index, the new ionospheric TEC-noon index based on GPS-derived Total Electron Content measurements at 288 IGS stations for 1994-2018. The regression relations are deduced between the different solar and ionospheric proxy indices smoothed by 12-month sliding window. The IG, TEC and GEC saturation or amplification effect is observed towards the solar maximum. The SSN1 and F10.7 data serve as a default IRI-Plas input while the rest indices are scaled to SSN1 units envisaged by the F2 layer peak maps. Relevant subroutines are incorporated in IRI-Plas system for automatic conversion of user's predefined index to other related indices which are applied by the different model procedures.
Kaplan, Amy J; Stacy, Nicole I; Jacobson, Elliott; Le-Bert, Carolina R; Nollens, Hendrik H; Origgi, Francesco C; Green, Linda G; Bootorabi, Shadi; Bolten, Alan; Hernandez, Jorge A
2016-01-01
The quantification of circulating plasma immunoglobulins represents a valuable diagnostic tool in human and veterinary immunology, although its application is very limited in reptile medicine to date. The objectives of our study were the development and standardization of a competitive enzyme-linked immunosorbent assay (cELISA) for the measurement of total plasma immunoglobulins (Igs; both IgM and IgY) in loggerhead sea turtles (LST; Caretta caretta; n = 254) and green turtles (GT; Chelonia mydas; n = 111), the establishment of reference intervals for Ig for both species, and the examination of associations between Ig and total protein (TP), condition index, and water temperature. The cELISA for Ig was successfully developed and optimized. Reference intervals for Ig were 0.38-0.94 g/dL in LST (median: 0.59 g/dL; range: 0.16-2.15 g/dL) and 0.40-0.85 g/dL in GT (median: 0.58 g/dL; range: 0.18-1.80 g/dL). In LST, there were positive linear relationships of Ig with TP, and TP with Ig and condition index, and a negative relationship of Ig with condition index. The positive linear relationships of Ig with TP, and TP with Ig were also identified in GT. These positive associations of Ig and TP were expected, as Ig represents fractions of TP, and TP reportedly increases with straight carapace length and weight. The negative association of Ig with condition index may indicate potential biological variations. The cELISA and reference intervals for total Ig of LST and GT presented herein have the potential to be useful as a diagnostic and research tool for sea turtle immunology. © 2015 The Author(s).
Implications of false positive serology of Toxoplasma gondii in a pre-transplant patient.
Beal, Stacy; Racsa, Lori; Alatoom, Adnan
2014-01-01
A 21-year-old white male with cystic fibrosis. Pre-transplant workup in preparation for bilateral lung transplant. Cystic fibrosis diagnosed at age 3, onset of insulin-dependent diabetes around age 20, and multiple hospitalizations for pulmonary and gastrointestinal complications. FAMILY AND SOCIAL HISTORY: The patient lives with his father and stepmother, has a pet bearded dragon, and has multiple tattoos and piercings. His stepmother has a cat, but he does not clean the litter box. The pre-transplant workup included several tests for infectious diseases, tests of organ function, radiology studies, and markers of malignancy. The only significant finding was a positive Toxoplasma gondii (T. gondii) IgM titer (> or = 1:40) (reference values for IgM: negative; < 1:40, positive; > or = 1:40) and IgG (1:2048) (reference values for IgG: negative; < 1:16, equivocal; > or = 1:16 - < 1:256, positive; > or = 1:256). Testing was done by indirect immunofluorescence assay (IFA) in April 2012 in our hospital laboratory. The patient was treated with sulfadiazine, leucovorin, and pyrimethamine. Three months later (July), he returned for follow-up testing. Real-time polymerase chain reaction (PCR) for T. gondii DNA performed by a reference laboratory was negative. One month later (August), Toxoplasma serology was performed by enzyme-linked immunosorbent assay (ELISA) by a different reference laboratory and showed an elevated IgM of 0.95 IU/mL (reference values: negative; < 0.55 IU/mL, equivocal; > or = 0.55- < 0.65 IU/mL, positive; > or = 0.65 IU/mL) and a normal level of IgG (< 4 IU/mL). At this time, PCR was repeated and was negative. An additional month later (September), the patient's serology studies were performed at a third reference laboratory and showed an elevated IgM of 1.32 IU/mL (reference values: negative; 0.89, equivocal; 0.90 - 1.09, positive; > 1.10) and a normal IgG.
Breadth of Scientific Activities and Network Station Specifications in the IGS
NASA Technical Reports Server (NTRS)
Moore, A. W.; Springer, T. A.; Reigber, Ch.
1999-01-01
This presentation provides a brief overview of the scientific activities of the International GPS Service (IGS). This was an approved activity of the International Association of Geodesy (IAG) with official start of service on 1 Jan 1994. The mission of the IGS is "To provide a service to support geodetic and geophysical research activities, through GPS data and data products." The presentation explains the concept of the IGS working group, and pilot projects, and reviews the current working groups and pilot projects.
Willis, Rohan; Pierangeli, Silvia S; Jaskowski, Troy D; Malmberg, Elisabeth; Guerra, Marta; Salmon, Jane E; Petri, Michelle; Branch, D Ware; Tebo, Anne E
2016-06-01
To investigate the performance characteristics and impact of newly developed reference calibrators on the commutability between anti-β2 glycoprotein I (anti-β2 GPI) immunoassays in antiphospholipid syndrome (APS) and/or systemic lupus erythematosus (SLE). Immunoglobulin G (IgG) and immunoglobulin M (IgM) anti-β2 GPI immunoassays from four manufacturers were evaluated. Serum samples from 269 patients (APS only, n = 31; SLE and APS, n = 83; SLE only, n = 129; pregnancy-related clinical manifestations without APS, n = 26) and 162 women with histories of successful pregnancies were tested. Results were expressed in kit-specific arbitrary units and in the calibrator reference units (RUs) based on 99th percentile cutoff values. Diagnostic accuracies, correlation between kits, and specific clinical manifestations in APS were investigated. The sensitivities of the assays ranged from 15.8% to 27.2% (IgG) and 12.3% to 15.8% (IgM) while specificities ranged from 79.4% to 86.5% (IgG) and 80.6% to 84.5% (IgM). There was moderate to almost perfect interassay reliability (Cohen κ, 0.69-0.98), and Spearman correlation coefficients were generally improved when results of the IgG determinations were expressed in RUs. Although qualitative agreements between immunoassays for both antibody isotypes are acceptable, correlations with APS clinical manifestations were kit dependent. Only the use of IgG reference material improved quantitative correlations between assays. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Kuranuki, Sachi; Sato, Toshiyuki; Okada, Seiki; Hosoya, Samiko; Seko, Akinobu; Sugihara, Kaya; Nakamura, Teiji
2013-01-01
To develop a minimally invasive interstitial fluid extraction technology (MIET) to monitor postprandial glucose area under the curve (AUC) without blood sampling, we evaluated the accuracy of glucose AUC measured by MIET and compared with that by blood sampling after food intake. Interstitial fluid glucose AUC (IG-AUC) following consumption of 6 different types of foods was measured by MIET. MIET consisted of stamping microneedle arrays, placing hydrogel patches on the areas, and calculating IG-AUC based on glucose levels in the hydrogels. Glycemic index (GI) was determined using IG-AUC and reference AUC measured by blood sampling. IG-AUC strongly correlated with reference AUC (R = 0.91), and GI determined using IG-AUC showed good correlation with that determined by reference AUC (R = 0.88). IG-AUC obtained by MIET can accurately predict the postprandial glucose excursion without blood sampling. In addition, feasibility of GI measurement by MIET was confirmed.
In search of periodic signatures in IGS REPRO1 solution
NASA Astrophysics Data System (ADS)
Mtamakaya, J. D.; Santos, M. C.; Craymer, M. R.
2010-12-01
We have been looking for periodic signatures in the REPRO1 solution recently released by the IGS. At this stage, a selected sub-set of IGS station time series in position and residual domain are under harmonic analysis. We can learn different things from this analysis. From the position domain, we can learn more about actual station motions. From the residual domain, we can learn more about mis-modelled or un-modelled errors. As far as error sources are concerned, we have investigated effects that may be due to tides, atmospheric loading, definition of the position of the figure axis and GPS constellation geometry. This poster presents and discusses our findings and presents insights on errors that need to be modelled or have their models improved.
Genetics Home Reference: X-linked hyper IgM syndrome
... Home Health Conditions X-linked hyper IgM syndrome X-linked hyper IgM syndrome Printable PDF Open All ... Javascript to view the expand/collapse boxes. Description X-linked hyper IgM syndrome is a condition that ...
The African Reference Frame (AFREF) project: a fundamental geodetic tool for Africa
NASA Astrophysics Data System (ADS)
Farah, H.
2009-04-01
AFREF has as objective the establishment and maintenance of a unified geodetic reference frame for Africa, which will support and facilitate fundamental scientific and technical projects. The installation of observation systems all over Africa will provide important data that can be used in many different scientific fields (e.g., geodynamics, meteorological). Furthermore, AFREF will create an uniform frame that will support development projects, uniform environmental and mapping programmes as well as aid in resolving current and future international boundary disputes. This reference frame will be based on the International Terrestrial Reference Frame (ITRF) and will be realised through the establishment of a network of permanent Global Navigation Satellite System (GNSS) receivers. In close collaboration with several institutional role players, AFREF is an initiative of the United Nations Economic Commission for Africa (UNECA) Committee on Development Information (CODI). A steering committee is currently responsible for the over-all management and coordination of the implementation of AFREF. Implementation of AFREF is envisaged to be at national level in collaboration with National Mapping Organizations. Furthermore, many scientific Institutions are contributing for the densification of the network. The current status of the AFREF network will be discussed in detail. Several CORS systems have been installed to support AFREF specifically. In addition, most or all of the IGS stations located in Africa will automatically qualify as AFREF core stations. Furthermore, we will show examples of interaction between specific projects and AFREF that are contributing for the development of science in Africa.
Meylan, Pascal; Paris, Luc; Liesenfeld, Oliver
2015-01-01
Detection of IgG and IgM antibodies is commonly performed for the diagnosis of infection with Toxoplasma gondii. We determined the accuracy of the Elecsys Toxo IgG and IgM test at four European laboratories compared to local reference methods. Coefficients of variation for reproducibility ranged from 1.0 to 6.5% for IgG and from 0.8 to 3.2% for IgM. Seroconversion panels revealed high overall concordance with the reference tests. The Elecsys test detected IgG antibodies earlier than the Cobas Core IgG test in 19 of 47 panels; persisting IgM antibodies were observed in the VIDAS but not the Elecsys test in five of 47 panels. In 31.4% of latent stage sera with persistent IgM antibodies (positive LIASON IgM), the Elecsys IgM test gave negative results indicating increased “clinical” specificity. Sensitivity and specificity of the Elecsys IgG assay ranged from 99.45 to 100% and 87.50–99.80%, respectively, and 91.11–95.74 and 98.45–99.79% for the Elecsys IgM assay, respectively. In conclusion, excellent reproducibility and accuracy make the Elecsys Toxo G and M tests highly suitable for the detection of anti-T. gondii IgG and IgM antibodies. The lower detection rates for persistent IgM in the Elecsys IgM test increase “clinical” specificity and decrease the need for follow-up testing. PMID:26185683
Operations of the International GPS Geodynamics Service (IGS)
NASA Technical Reports Server (NTRS)
Beutler, G.; Neilan, R.; Mueller, I.
1993-01-01
This paper focuses on the operations, organization, and interfaces of the International GPS Geodynamics Service (IGS) which is expected to contribute to geodesy for many years to come. It briefly summarizes the history of the IGS, reports on IGS '92 campaign activities, and describes the current IGS terms of reference and proposal status.
Absolute IGS antenna phase center model igs08.atx: status and potential improvements
NASA Astrophysics Data System (ADS)
Schmid, R.; Dach, R.; Collilieux, X.; Jäggi, A.; Schmitz, M.; Dilssner, F.
2016-04-01
On 17 April 2011, all analysis centers (ACs) of the International GNSS Service (IGS) adopted the reference frame realization IGS08 and the corresponding absolute antenna phase center model igs08.atx for their routine analyses. The latter consists of an updated set of receiver and satellite antenna phase center offsets and variations (PCOs and PCVs). An update of the model was necessary due to the difference of about 1 ppb in the terrestrial scale between two consecutive realizations of the International Terrestrial Reference Frame (ITRF2008 vs. ITRF2005), as that parameter is highly correlated with the GNSS satellite antenna PCO components in the radial direction.
Computation of Estonian CORS data using Bernese 5.2 and Gipsy 6.4 softwares
NASA Astrophysics Data System (ADS)
Kollo, Karin; Kall, Tarmo; Liibusk, Aive
2017-04-01
GNSS permanent station network in Estonia (ESTREF) was established already in 2007. In 2014-15 extensive reconstruction of ESTREF was carried out, including the establishment of 18 new stations, change of the hardware in CORS stations as well as establishing GNSS-RTK service for the whole Estonia. For GNSS-RTK service one needs precise coordinates in well-defined reference frame, i.e., ETRS89. For long time stability of stations and time-series analysis the re-processing of Estonian CORS data is ongoing. We re-process data from 2007 until 2015 with program Bernese GNSS 5.2 (Dach, 2015). For the set of ESTREF stations established in 2007, we perform as well computations with GIPSY 6.4 software (Ries et al., 2015). In the computations daily GPS-only solution was used. For precise orbits, final products from CODE (CODE analysis centre at the Astronomical Institute of the University of Bern) and JPL (Jet Propulsion Laboratory) for Bernese and GIPSY solutions were used, respectively. The cut-off angle was set to 10 degrees in order to avoid near-field multipath influence. In GIPSY, precise point positioning method with fixing ambiguities was used. Bernese calculations were performed based on double difference processing. Antenna phase centers were modelled based on igs08.atx and epnc_08.atx files. Vienna mapping function was used for mapping tropospheric delays. For the GIPSY solution, the higher order ionospheric term was modelled based on IRI-2012b model. For the Bernese solution higher order ionospheric term was neglected. FES2004 ocean tide loading model was used for the both computation strategies. As a result, two solutions using different scientific GNSS computation programs were obtained. The results from Bernese and GIPSY solutions were compared, using station repeatability values, RMS and coordinate differences. KEYWORDS: GNSS reference station network, Bernese GNSS 5.2, Gipsy 6.4, Estonia. References: Dach, R., S. Lutz, P. Walser, P. Fridez (Eds); 2015: Bernese GNSS Software Version 5.2. User manual, Astronomical Institute, Universtiy of Bern, Bern Open Publishing. DOI: 10.7892/boris.72297; ISBN: 978-3-906813-05-9. Paul Ries, Willy Bertiger, Shailen, Shailen Desai, & Kevin Miller. (2015). GIPSY 6.4 Release Notes. Jet Propulsion Laboratory, California Institute of Technology. Retrieved from https://gipsy-oasis.jpl.nasa.gov/docs/index.php
Schlünssen, Vivi; Kespohl, Sabine; Jacobsen, Gitte; Raulf-Heimsoth, Monika; Schaumburg, Inger; Sigsgaard, Torben
2011-03-01
Wood dust exposure may cause Immunoglobulin E (IgE)-mediated allergic diseases. Our objectives were to estimate pine and beech dust sensitization rates among woodworkers and a reference group, explore the association between exposure and sensitization and between sensitization and respiratory symptoms, and finally investigate the impact of proteinogenic specific IgE (sIgE) epitopes on respiratory symptoms. In a Danish study among 52 furniture factories and 2 reference factories, we evaluated the workers' asthma and rhinitis status using questionnaires and blood samples collected from 1506 woodworkers and 195 references. Workers with asthma symptoms (N=298), a random study sample (N=399) and a random rhinitis sample (N=100) were evaluated for IgE-mediated sensitization to pine and beech dust. The prevalence of pine and beech sensitization among current woodworkers was 1.7 and 3.1%, respectively. No differences in sensitization rates were found between woodworkers and references, but the prevalence of wood dust sensitization was dose-dependently associated with the current level of wood dust exposure. No relation was observed between wood dust sensitization per se and respiratory symptoms. Only symptomatic subjects had proteinogenic IgE epitopes to pine. Increased odds ratios for sIgE based on proteinogenic epitopes to beech and respiratory symptoms were found, although they were not statistically significant. Sensitization rates to pine and beech were the same for woodworkers and references but dependent on the current wood dust exposure level. The importance of beech and pine wood sensitization is limited, but may be of clinical significance for a few workers if the IgE epitopes are proteinogenic.
Flori, Pierre; Delaunay, Edouard; Guillerme, Cécile; Charaoui, Sana; Raberin, Hélène; Hafid, Jamal; L'Ollivier, Coralie
2017-01-01
ABSTRACT A study comparing the ICT (immunochromatography technology) Toxoplasma IgG and IgM rapid diagnostic test (LDBio Diagnostics, France) with a fully automated system, Architect, was performed on samples from university hospitals of Marseille and Saint-Etienne. A total of 767 prospective sera and 235 selected sera were collected. The panels were selected to test various IgG and IgM parameters. The reference technique, Toxoplasma IgGII Western blot analysis (LDBio Diagnostics), was used to confirm the IgG results, and commercial kits Platelia Toxo IgM (Bio-Rad) and Toxo-ISAgA (bioMérieux) were used in Saint-Etienne and Marseille, respectively, as the IgM reference techniques. Sensitivity and specificity of the ICT and the Architect IgG assays were compared using a prospective panel. Sensitivity was 100% for the ICT test and 92.1% for Architect (cutoff at 1.6 IU/ml). The low-IgG-titer serum results confirmed that ICT sensitivity was superior to that of Architect. Specificity was 98.7% (ICT) and 99.8% (Architect IgG). The ICT test is also useful for detecting IgM without IgG and is both sensitive (100%) and specific (100%), as it can distinguish nonspecific IgM from specific Toxoplasma IgM. In comparison, IgM sensitivity and specificity on Architect are 96.1% and 99.6%, respectively (cutoff at 0.5 arbitrary units [AU]/ml). To conclude, this new test overcomes the limitations of automated screening techniques, which are not sensitive enough for IgG and lack specificity for IgM (rare IgM false-positive cases). PMID:28954897
A Newly Reanalyzed Dataset of GPS-determined Antarctic Vertical Rates
NASA Astrophysics Data System (ADS)
Thomas, I.; King, M.; Clarke, P. J.; Penna, N. T.; Lavallee, D. A.; Whitehouse, P.
2010-12-01
Accurate and precise measurements of vertical crustal motion offer useful constraints on glacial isostatic adjustment (GIA) models. Here we present a newly reprocessed data set of GPS-determined vertical rates for Antarctica. We give details of the global reanalysis of 15-years of GPS data, the overarching aim of which is to achieve homogeneous station coordinate time series, and hence surface velocities, for GPS receivers that are in regions of GIA interest in Antarctica. The means by which the reference frame is realized is crucial to obtaining accurate rates. Considerable effort has been spent on achieving a good global distribution of GPS stations, using data from IGS and other permanently recording stations, as well as a number of episodic campaigns in Antarctica. Additionally, we have focused on minimizing the inevitable imbalance in the number of sites in the northern and southern hemispheres. We align our daily non-fiducial solutions to ITRF2005, i.e. a CM frame. We present the results of investigations into the reference frame realization, and also consider a GPS-derived realization of the frame, and its effect on the vertical velocities. Vertical velocities are obtained for approximately 40 Antarctic locations. We compare our GPS derived Antarctic vertical rates with those predicted by the Ivins and James and ICE-5G models, after converting to a CE frame. We also compare to previously published GPS rates. Our GPS velocities are being used to help tune, and bound errors of, a new GIA model also presented in this session.
DORIS and GNSS processing at CNES/CLS for the contribution to the next ITRF2013
NASA Astrophysics Data System (ADS)
Loyer, Sylvain; Capdeville, Hugues; Soudarin, Laurent; Mezerette, Adrien; Lemoine, Jean-Michel; Mercier, Flavien; Perosanz, Felix
2014-05-01
CNES serves as Analysis Center in the International DORIS Service (IDS) and the International GNSS Service (IGS). DORIS and GNSS data are processed by its subsidiary CLS with the GRGS package software GINS/DYNAMO. For the contribution to the next release of the International Terrestrial Reference Frame planned this year (ITRF2013), two decades of data were analyzed (1993-2013 for DORIS, 1998-2013 for GPS, and 2009-2013 for GLONASS). In this context, the CNES/CLS Analysis Centers provided SINEX solutions to the IDS and IGS Combination Centers, respectively multi-satellite weekly solutions and daily solutions. Normal equations derived from this analysis are also made available to the GRGS Combination Center for the combination at the observation level of the geodetic parameters measured by DORIS, GPS, SLR and VLBI techniques. The purpose of this presentation is to point out how the overall quality of the DORIS and GNSS data processing benefits from the use of the same software and a common basis of models. Here, we present the modeling standards, the networks and the processing strategies. Assessments of some models are also discussed. The quality and the homogeneity of the products (orbits, station coordinates and Earth Orientation Parameters) over the complete period are shown, as well as the temporal variations of some parameters (dynamical parameters, orbit residuals, internal orbit overlaps ...). Some examples of time series of DORIS and GNSS station positions at collocated sites complete this presentation.
NASA's Next Generation Space Geodesy Network
NASA Technical Reports Server (NTRS)
Desai, S. D.; Gross, R. S.; Hilliard, L.; Lemoine, F. G.; Long, J. L.; Ma, C.; McGarry, J. F.; Merkowitz, S. M.; Murphy, D.; Noll, C. E.;
2012-01-01
NASA's Space Geodesy Project (SGP) is developing a prototype core site for a next generation Space Geodetic Network (SGN). Each of the sites in this planned network co-locate current state-of-the-art stations from all four space geodetic observing systems, GNSS, SLR, VLBI, and DORIS, with the goal of achieving modern requirements for the International Terrestrial Reference Frame (ITRF). In particular, the driving ITRF requirements for this network are 1.0 mm in accuracy and 0.1 mm/yr in stability, a factor of 10-20 beyond current capabilities. Development of the prototype core site, located at NASA's Geophysical and Astronomical Observatory at the Goddard Space Flight Center, started in 2011 and will be completed by the end of 2013. In January 2012, two operational GNSS stations, GODS and GOON, were established at the prototype site within 100 m of each other. Both stations are being proposed for inclusion into the IGS network. In addition, work is underway for the inclusion of next generation SLR and VLBI stations along with a modern DORIS station. An automated survey system is being developed to measure inter-technique vectorties, and network design studies are being performed to define the appropriate number and distribution of these next generation space geodetic core sites that are required to achieve the driving ITRF requirements. We present the status of this prototype next generation space geodetic core site, results from the analysis of data from the established geodetic stations, and results from the ongoing network design studies.
Vagus Nerve Stimulation as a Treatment Strategy for Gulf War Illness
2016-10-01
5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) TEXAS A&M UNIVERSITY SYSTEM ,THE 200 TECHNOLOGY WAY, STE 2079COLLEGE STATION...IgD) expression in splenocytes. IgD is an immunoglobulin that appears in species with an adaptive immune system . Among its numerous activities in the
NASA Astrophysics Data System (ADS)
Bartsch, M.; Merx, A.; Falck, C.; Ramatschi, M.
2010-05-01
Introduction Within the GITEWS (German Indonesian Tsunami Early Warning System) project a near real-time GNSS processing system has been developed, which analizes on- and offshore measured GNSS data. It is the first system of its kind that was integrated into an operational tsunami early warning system. (Indonesian Tsunami Early Warning Centre INATEWS, inaugurated at BMKG Jakarta on November, 11th 2008) Brief system description The GNSS data to be processed are received from sensors (GNSS antenna and receiver) installed on buoys, at tide gauges and as real-time reference stations (RTR stations), either stand-alone or co-located with seismic sensors. The GNSS data are transmitted to the warning centre in real-time as a stream (RTR stations) or file-based and are processed in a near real-time data processing chain. The fully automatized system uses the BERNESE GPS software as processing core. Kinematic coordinate timeseries with a resolution of 1 Hz (landbased stations) and 1/3 Hz (buoys) are estimated every five minutes. In case of a recently occured earthquake the processing interval decreases from five to two minutes. All stations are processed with the relative technique (baseline-technique) using GITEWS-stations and stations available via IGS as reference. The most suitable reference stations are choosen by querying a database where continiously monitored quality data of GNSS observations are stored. In case of an earthquake at least one reference station should be located on a different tectonic plate to ensure that relative movements can be detected. The primary source for satellite orbit information is the IGS IGU product. If this source is not available for any reason, the system switches automatically to other orbit sources like CODE products or broadcast ephemeris data. For sensors on land the kinematic coordinates are used to detect deviations from their normal, mean coordinates. The deviations or so called displacements are indicators for land mass movements which can occur, e.g., due to strong earthquakes. The ground motion information is a valuable source for a fast understanding of an earthquake's mechanism and consequences with possible relevance for a potentially following tsunami. Regarding kinematic coordinates of a buoy only the vertical component is of interest as it corresponds to the instant sea level. The kinematic coordinates are delivered to an oceanographic post-processing unit which applies dipping-, tilting- and tidal-corrections to the data. Deviations to the mean sea level are an indicator for a possibly passing tsunami wave. By this means the GNSS system supports the decision finding process whether a tsunami has been released or not. A graphical user interface (GUI) was developed which monitors the whole processing chain from data transmission and GNSS data processing to the displaying of the kinematic coordinate time series. It supports both, a quick view for all staff members at the warning centre (24h/7d shifts) and deeper analysis by GNSS experts. The GNSS GUI system is web-based and allows all views to be displayed on different screens at the same time, even at remote locations. This is part of the concept, as it can support the dialogue between warning centre staff on duty or on standby and sensor station maintenance staff. Acknowledgements The GITEWS project (German Indonesian Tsunami Early Warning System) is carried out by a large group of scientists and engineers from (GFZ) German Research Centre for Geosciences and its partners from the German Aerospace Centre (DLR), the Alfred Wegener Institute for Polar and Marine Research (AWI), the GKSS Research Centre, the Konsortium Deutsche Meeresforschung (KDM), the Leibniz Institute for Marine Sciences (IFM-GEOMAR), the United Nations University (UNU), the Federal Institute for Geosciences and Natural Resources (BGR), the German Agency for Technical Cooperation (GTZ) and other international partners. Most relevant partners in Indonesia with respect to the GNSS component of GITEWS are the National Coordinating Agency for Surveys and Mapping (BAKOSURTANAL), the National Metereology and Geophysics Agency (BMG) and the National Agency for the Assessment and Application of Technology (BPPT). Funding is provided by the German Federal Ministry for Education and Research (BMBF), Grant 03TSU01.
The Effect of Improved Sub-Daily Earth Rotation Models on Global GPS Data Processing
NASA Astrophysics Data System (ADS)
Yoon, S.; Choi, K. K.
2017-12-01
Throughout the various International GNSS Service (IGS) products, strong periodic signals have been observed around the 14 day period. This signal is clearly visible in all IGS time-series such as those related to orbit ephemerides, Earth rotation parameters (ERP) and ground station coordinates. Recent studies show that errors in the sub-daily Earth rotation models are the main factors that induce such noise. Current IGS orbit processing standards adopted the IERS 2010 convention and its sub-daily Earth rotation model. Since the IERS convention had published, recent advances in the VLBI analysis have made contributions to update the sub-daily Earth rotation models. We have compared several proposed sub-daily Earth rotation models and show the effect of using those models on orbit ephemeris, Earth rotation parameters and ground station coordinates generated by the NGS global GPS data processing strategy.
Performance Assessment of a Gnss-Based Troposphere Path Delay Estimation Software
NASA Astrophysics Data System (ADS)
Mariotti, Gilles; Avanzi, Alessandro; Graziani, Alberto; Tortora, Paolo
2013-04-01
Error budgets of Deep Space Radio Science experiments are heavily affected by interplanetary and Earth transmission media, that corrupt, due to their non-unitary refraction index, the radiometric information of signals coming from the spacecraft. An effective removal of these noise sources is crucial to achieve the accuracy and signal stability levels required by radio science applications. Depending on the nature of these refractions, transmission media are divided into dispersive (that consists of ionized particles, i.e. Solar Wind and Ionosphere) and non-dispersive ones (the refraction is caused by neutral particles: Earth Troposphere). While dispersive noises are successfully removed by multifrequency combinations (as for GPS with the well-known ionofree combination), the most accurate estimation of tropospheric noise is obtained using microwave radiometers (MWR). As the use of MWRs suffers from strong operational limitations (rain and heavy clouds conditions), the GNSS-based processing is still widely adopted to provide a cost-effective, all-weather condition estimation of the troposphere path delay. This work describes the development process and reports the results of a GNSS analysis code specifically aimed to the estimation of the path delays introduced by the troposphere above deep space complexes, to be used for the calibration of Range and Doppler radiometric data. The code has been developed by the Radio Science Laboratory of the University of Bologna in Forlì, and is currently in the testing phase. To this aim, the preliminary output is compared to MWR measurements and IGS TropoSINEX products in order to assess the reliability of the estimate. The software works using ionofree carrier-phase observables and is based upon a double-difference approach, in which the GNSS receiver placed nearby the Deep Space receiver acts as the rover station. Several baselines are then created with various IGS and EUREF stations (master or reference stations) in order to perform the differentiation. The code relies on several IGS products, like SP3 precise orbits and SINEX positions available for the master stations in order to remove several error components, while the phase ambiguities (both wide and narrow lane) are resolved using the modified LAMBDA (MLAMBDA) method. The double-differenced data are then processed by a Kalman Filter that estimates the contingent positioning error of the rover station, its Zenith Wet Delay (ZWD) and the residual phase ambiguities. On the other hand, the Zenith Hydrostatic Delay (ZHD) is preliminarily computed using a mathematical model, based on surface meteorological measurements. The final product of the developed code is an output file containing the estimated ZWD and ZHD time-series in a format compatible with the major orbit determination software, e.g. the CSP card format (TRK-2-23) used by NASA JPL's Orbit Determination Program.
Presence of specific IgG antibody to grain dust does not go with respiratory symptoms.
Park, H. S.; Suh, C. H.; Nahm, D. H.; Kim, H. Y.
1999-01-01
A high prevalence of work-related symptoms in relation to grain dust exposure has been reported in grain dust workers, but the role of the specific IgG antibody is unknown. To study the possible role of specific IgG (sIgG) and specific IgG4 (sIgG4) in the development of work-related symptoms, sIgG and sIgG4 subclass antibodies against grain dust antigens were determined by ELISA in sera from 43 workers and 27 non-exposed controls. They were compared with results of specific IgE antibodies, exposure intensity and the presence of respiratory symptoms. SIgG and sIgG4 antibodies were detectable in almost all sera of exposed workers, and the prevalence were significantly higher than those of controls (p<0.05). Higher sIgG4 was noted in workers with specific IgE (p<0.05). The correlation between sIgG and exposure duration was significant (p<0.05). There was no association between the prevalence of sIgG and sIgG4 and the presence of respiratory symptoms, or work stations. In conclusion, these results suggest that the existence of sIgG and sIgG4 might represent a response to grain dust exposure and may unlikely play a role in the etiology of respiratory symptoms. PMID:10102522
Presence of specific IgG antibody to grain dust does not go with respiratory symptoms.
Park, H S; Suh, C H; Nahm, D H; Kim, H Y
1999-02-01
A high prevalence of work-related symptoms in relation to grain dust exposure has been reported in grain dust workers, but the role of the specific IgG antibody is unknown. To study the possible role of specific IgG (sIgG) and specific IgG4 (sIgG4) in the development of work-related symptoms, sIgG and sIgG4 subclass antibodies against grain dust antigens were determined by ELISA in sera from 43 workers and 27 non-exposed controls. They were compared with results of specific IgE antibodies, exposure intensity and the presence of respiratory symptoms. SIgG and sIgG4 antibodies were detectable in almost all sera of exposed workers, and the prevalence were significantly higher than those of controls (p<0.05). Higher sIgG4 was noted in workers with specific IgE (p<0.05). The correlation between sIgG and exposure duration was significant (p<0.05). There was no association between the prevalence of sIgG and sIgG4 and the presence of respiratory symptoms, or work stations. In conclusion, these results suggest that the existence of sIgG and sIgG4 might represent a response to grain dust exposure and may unlikely play a role in the etiology of respiratory symptoms.
Immunoturbidimetric quantification of serum immunoglobulin G concentration in foals.
Bauer, J E; Brooks, T P
1990-08-01
Immunoturbidimetric determination of serum IgG concentration in foals was compared with the reference methods of single radial immunodiffusion and serum protein electrophoresis. High positive correlations were discovered when the technique was compared with either of these reference methods. The zinc sulfate turbidity test for serum IgG estimation was also evaluated. Although a positive correlation was discovered when the latter method was compared with reference methods, it was not as strong as the correlation between reference methods and the immunoturbidimetric method. The immunoturbidimetric method used in this study is specific and precise for equine serum IgG determination. It is rapid and, thus, is advantageous when timely evaluation of critically ill foals is necessary. The technique should be adaptable to various spectrophotometers and microcomputers for widespread application in veterinary medicine.
GNSS monitoring of the ionosphere for Space Weather services
NASA Astrophysics Data System (ADS)
Krankowski, A.; Sieradzki, R.; Zakharenkova, I. E.; Cherniak, I. V.
2012-04-01
The International GNSS Service (IGS) Ionosphere Working Group routinely provides the users global ionosphere maps (GIMs) of vertical total electron content (vTEC). The IGS GIMs are provided with spatial resolution of 5.0 degrees x 2.5 degrees in longitude and latitude, respectively. The current temporal resolution is 2 hours, however, 1-hour maps are delivered as a pilot project. There are three types IGS GIMs: the final, rapid and predicted. The latencies of the IGS ionospheric final and rapid products are 10 days and 1 day, respectively. The predicted GIMs are generated for 1 and 2 days in advance. There are four IGS Associate Analysis Centres (IAACs) that provide ionosphere maps computed with independent methodologies using GNSS data. These maps are uploaded to the IGS Ionosphere Combination and Validation Center at the GRL/UWM (Geodynamics Research Laboratory of the University of Warmia and Mazury in Olsztyn, Poland) that produces the IGS official ionospheric products, which are published online via ftp and www. On the other hand, the increasing number of permanently tracking GNSS stations near the North Geomagnetic Pole allow for using satellite observations to detect the ionospheric disturbances at high latitudes with even higher spatial resolution. In the space weather service developed at GRL/UWM, the data from the Arctic stations belonging to IGS/EPN/POLENET networks were used to study TEC fluctuations and scintillations. Since the beginning of 2011, a near real-time service presenting the conditions in the ionosphere have been operational at GRL/UWM www site. The rate of TEC index (ROTI) expressed in TECU/min is used as a measure of TEC fluctuations. The service provides 2-hour maps of the TEC variability. In addition, for each day the daily map of the ionospheric fluctuations as a function geomagnetic local time is also created. This presentation shows the architecture, algorithms, performance and future developments of the IGS GIMs and this new space weather service at GRL/UWM.
Assessment of models proposed for the 1981 revision of the IGRF.
Peddie, N.W.; Fabiano, E.B.
1982-01-01
For the second revision of the International Geomagnetic Reference Field (IGRF), the US National Aeronautics and Space Administration (NASA), the UK Institute of Geological Sciences (IGS), and the US Geological Survey (USGS) submitted proposed models of the Earth's main magnetic field at 1965.0, 1970.0, 1975.0, and 1980.0, and its secular variation during 1980-1985. We assessed the proposed models by comparing them with annual mean values from worldwide magnetic observatories data for 1978-1980 from 63 US magnetic repeat stations, and rates-of-change values for worldwide magnetic observatories for 1965-1985 that were derived from straight lines fitted to annual means for 5-yr intervals. We also mutually compared the 1980 models.-from Authors
Lundgren, A; Leach, S; Tobias, J; Carlin, N; Gustafsson, B; Jertborn, M; Bourgeois, L; Walker, R; Holmgren, J; Svennerholm, A-M
2013-02-06
We have developed a new oral vaccine against enterotoxigenic Escherichia coli (ETEC) diarrhea containing killed recombinant E. coli bacteria expressing increased levels of ETEC colonization factors (CFs) and a recombinant protein (LCTBA), i.e. a hybrid between the binding subunits of E. coli heat labile toxin (LTB) and cholera toxin (CTB). We describe a randomized, comparator controlled, double-blind phase I trial in 60 adult Swedish volunteers of a prototype of this vaccine. The safety and immunogenicity of the prototype vaccine, containing LCTBA and an E. coli strain overexpressing the colonization factor CFA/I, was compared to a previously developed oral ETEC vaccine, consisting of CTB and inactivated wild type ETEC bacteria expressing CFA/I (reference vaccine). Groups of volunteers were given two oral doses of either the prototype or the reference vaccine; the prototype vaccine was administered at the same or a fourfold higher dosage than the reference vaccine. The prototype vaccine was found to be safe and equally well-tolerated as the reference vaccine at either dosage tested. The prototype vaccine induced mucosal IgA (fecal secretory IgA and intestine-derived IgA antibody secreting cell) responses to both LTB and CFA/I, as well as serum IgA and IgG antibody responses to LTB. Immunization with LCTBA resulted in about twofold higher mucosal and systemic IgA responses against LTB than a comparable dose of CTB. The higher dose of the prototype vaccine induced significantly higher fecal and systemic IgA responses to LTB and fecal IgA responses to CFA/I than the reference vaccine. These results demonstrate that CF over-expression and inclusion of the LCTBA hybrid protein in an oral inactivated ETEC vaccine does not change the safety profile when compared to a previous generation of such a vaccine and that the prototype vaccine induces significant dose dependent mucosal immune responses against CFA/I and LTB. Copyright © 2013 Elsevier Ltd. All rights reserved.
Coexistence of Acute Crescent Glomerulonephritis and IgG4-Related Kidney Disease.
Lu, Zeyuan; Yin, Jianyong; Bao, Hongda; Jiao, Qiong; Wu, Huijuan; Wu, Rui; Xue, Qin; Wang, Niansong; Zhang, Zhigang; Wang, Feng
2016-01-01
IgG4-related disease (IgG4-RD) is a fibroinflammatory disorder that may involve almost each organ or system. IgG4-related kidney disease (IgG4-RKD) refers to renal lesions associated with IgG4-RD. The most frequent morphological type of renal lesions is IgG4-related tubulointerstitial nephritis (IgG4-TIN) which is associated with increased IgG4-positive plasma cell infiltration and interstitial fibrosis. Herein, we present a rare case with coexisting IgG4-RKD and acute crescent glomerulonephritis with concomitant severe tubulointerstitial lesions instead of classic IgG4-TIN. IgG4-RKD and acute crescent glomerulonephritis can occur in the same patient. This case may give us a clearer viewpoint of the disease.
Maple, P A C; Breuer, J; Quinlivan, M; Kafatos, G; Brown, K E
2012-03-01
Recently, a commercial, standardised VZV IgG glycoprotein EIA, Binding Site VaccZyme™VZV glycoprotein IgG low level EIA (VaccZyme™EIA) has become available. The VaccZyme™EIA is more robust and user friendly than the reference VZV time-resolved fluorescence immunoassay (VZV TRFIA). To assess the usefulness of the VaccZyme™EIA in the diagnostic laboratory by comparing VZV IgG levels generated by both assays on serum panels representing, non-vaccinated, and vOka vaccinated populations. Sera from non-vaccinated individuals were tested; 248 from pregnant women, 117 from various patient groups referred to the Virus Reference Department for confirmatory VZV IgG testing and 102 from healthcare workers enrolled in a study (ROVE) of antibody/IgG response to vOka. From the ROVE study, 282 post vaccination sera were tested; 108 and 101 collected at six weeks post first and second doses of vOka, respectively, and 73 collected at 18 month follow-up. Sensitivities and specificities (equivocals treated as negatives) of the VaccZyme™EIA for sera from pregnant women were 97.8% (95% CI: [94.6%, 99.4%]) and 96.8% (95% CI: [89.0%, 99.6%]), respectively, and for sera referred for confirmatory testing were 81.2% (95% CI: [71.2%, 88.8%]) and 96.9% (95% CI: [83.8%, 99.9%]), respectively, and for ROVE baseline sera were 54.2% (95% CI: [32.8%, 74.4%]) and 100% (95% CI: [95.4%, 100.0%]), respectively. For the post vOka serum panels sensitivities of the VaccZyme™EIA ranged from 65.3% (95% CI: [50.4%, 78.3%]) to 80.4% (95% CI: [71.1%, 87.8%]). Specificities were all 100%. Correlation with VZV TRFIA was high and agreement varied between the serum panels tested. VaccZyme™EIA is recommended for detecting VZV IgG in sera from non-vaccinated populations; however, caution is advised when measuring post vOka VZV IgG levels. Copyright © 2011 Elsevier B.V. All rights reserved.
Li, Xiaoyang; Pomares, Christelle; Gonfrier, Géraldine; Koh, Byumseok; Zhu, Shoujun; Gong, Ming
2016-01-01
Toxoplasmosis is an infection caused by the protozoan parasite Toxoplasma gondii that can lead to severe sequelae in the fetus during pregnancy. Definitive serologic diagnosis of the infection during gestation is made mostly by detecting T. gondii-specific antibodies, including IgG and IgM, individually in a single serum sample by using commercially available kits. The IgA test is used by some laboratories as an additional marker of acute infection. Most of the commercial tests have failed to reach 100% correlation with the reference method, the Sabin-Feldman dye test for the detection of Toxoplasma IgG antibodies. For Toxoplasma IgM and IgA antibodies, there is no reference method and their evaluation is done by comparing the results of one assay to those of another. There is a need for multiplexed assay platforms, as the serological diagnosis of T. gondii infection does not rely on the detection of a single Ig subtype. Here we describe the development of a plasmonic gold chip with vast fluorescence enhancement in the near-infrared region for simultaneous detection of IgG, IgM, and IgA antibodies against T. gondii in an ∼1-μl serum or whole-blood sample. When 168 samples were tested on this platform, IgG antibody detection sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were all 100%. IgM antibody detection achieved 97.6% sensitivity and 96.9% specificity with a 90.9% PPV and a 99.2% NPV. Thus, the nanoscience-based plasmonic gold platform enables a high-performance, low-cost, multiplexed assay requiring ultrasmall blood volumes, paving the way for the implementation of universal screening for toxoplasmosis infection during gestation. PMID:27008879
A New Method with General Diagnostic Utility for the Calculation of Immunoglobulin G Avidity
Korhonen, Maria H.; Brunstein, John; Haario, Heikki; Katnikov, Alexei; Rescaldani, Roberto; Hedman, Klaus
1999-01-01
The reference method for immunoglobulin G (IgG) avidity determination includes reagent-consuming serum titration. Aiming at better IgG avidity diagnostics, we applied a logistic model for the reproduction of antibody titration curves. This method was tested with well-characterized serum panels for cytomegalovirus, Epstein-Barr virus, rubella virus, parvovirus B19, and Toxoplasma gondii. This approach for IgG avidity calculation is generally applicable and attains the diagnostic performance of the reference method while being less laborious and twice as cost-effective. PMID:10473525
Monitoring of stability of ASG-EUPOS network coordinates
NASA Astrophysics Data System (ADS)
Figurski, M.; Szafranek, K.; Wrona, M.
2009-04-01
ASG-EUPOS (Active Geodetic Network - European Position Determination System) is the national system of precise satellite positioning in Poland, which increases a density of regional and global GNSS networks and is widely used by public administration, national institutions, entrepreneurs and citizens (especially surveyors). In near future ASG-EUPOS is to take role of main national network. Control of proper activity of stations and realization of ETRS'89 is a necessity. User of the system needs to be sure that observations quality and coordinates accuracy are high enough. Coordinates of IGS (International GNSS Service) and EPN (European Permanent Network) stations are precisely determined and any changes are monitored all the time. Observations are verified before they are archived in regional and global databases. The same applies to ASG-EUPOS. This paper concerns standardization of GNSS observations from different stations (uniform adjustment), examination of solutions correctness according to IGS and EPN standards and stability of solutions and sites activity
Wang, Erlong; Wang, Kaiyu; Chen, Defang; Wang, Jun; He, Yang; Long, Bo; Yang, Lei; Yang, Qian; Geng, Yi; Huang, Xiaoli; Ouyang, Ping; Lai, Weimin
2015-01-01
qPCR as a powerful and attractive methodology has been widely applied to aquaculture researches for gene expression analyses. However, the suitable reference selection is critical for normalizing target genes expression in qPCR. In the present study, six commonly used endogenous controls were selected as candidate reference genes to evaluate and analyze their expression levels, stabilities and normalization to immune-related gene IgM expression during vaccination and infection in spleen of tilapia with RefFinder and GeNorm programs. The results showed that all of these candidate reference genes exhibited transcriptional variations to some extent at different periods. Among them, EF1A was the most stable reference with RefFinder, followed by 18S rRNA, ACTB, UBCE, TUBA and GAPDH respectively and the optimal number of reference genes for IgM normalization under different experiment sets was two with GeNorm. Meanwhile, combination the Cq (quantification cycle) value and the recommended comprehensive ranking of reference genes, EF1A and ACTB, the two optimal reference genes, were used together as reference genes for accurate analysis of immune-related gene expression during vaccination and infection in Nile tilapia with qPCR. Moreover, the highest IgM expression level was at two weeks post-vaccination when normalized to EF1A, 18S rRNA, ACTB, and EF1A together with ACTB compared to one week post-vaccination before normalizing, which was also consistent with the IgM antibody titers detection by ELISA. PMID:25941937
The new version 2.12 of BKG Ntrip Client (BNC)
NASA Astrophysics Data System (ADS)
Stürze, Andrea; Mervart, Leos; Weber, Georg; Rülke, Axel; Wiesensarter, Erwin; Neumaier, Peter
2016-04-01
A new version of the BKG Ntrip Client (BNC) has been released. Originally developed in cooperation of the Federal Agency for Cartography and Geodesy (BKG) and the Czech Technical University (CTU) with a focus on multi-stream real-time access to GPS observations, the software has once again been substantially extended. Promoting Open Standards as recommended by the Radio Technical Commission for Maritime Services (RTCM) remains the prime subject. Beside its Graphical User Interface (GUI), the real-time software for Windows, Linux, Mac, and Linux platforms now comes with complete Command Line Interface (CLI) and considerable post processing functionality. RINEX Version 3 file editing & Quality Check (QC) with full support of Galileo, BeiDou, and SBAS - besides GPS and GLONASS - is part of the new features. Comparison of satellite orbit/clock files in SP3 format is another fresh ability of BNC. Simultaneous multi-station Precise Point Positioning (PPP) for real-time displacement-monitoring of entire reference station networks is one more recent addition to BNC. Implemented RTCM messages for PPP (under development) comprise satellite orbit and clock corrections, code and phase observation biases, and the Vertical Total Electron Content (VTEC) of the ionosphere. The well established, mature codebase is mostly written in C++ language. Its publication under GNU GPL is thought to be well-suited for test, validation and demonstration of new approaches in precise real-time satellite navigation when IP streaming is involved. The poster highlights BNC features which are new in version 2.12 and beneficial to IAG institutions and services such as IGS/RT-IGS and to the interested public in general.
Zwerink, M; Zomer, T P; van Kooten, B; Blaauw, G; van Bemmel, T; van Hees, B C; Vermeeren, Y M; Landman, G W
2018-03-01
A two-step testing strategy is recommended in serological testing for Lyme borreliosis; positive and indeterminate enzyme-linked immunosorbent assay (ELISA) results are confirmed with immunoblots. Several ELISAs quantify the concentration of antibodies tested, however, no recommendation exists for an upper cut-off value at which an IgG ELISA is sufficient and the immunoblot can be omitted. The study objective was to determine at which IgG antibody level an immunoblot does not have any additional predictive value compared to ELISA results. Data of adult patients who visited a tertiary Lyme centre between 2008 and 2014 were analysed. Both an ELISA (Enzygnost Lyme link VlsE IgG) and immunoblot (recomLine blot Borrelia) were performed. Clinical data were extracted from the patient's digital medical record. Positive predictive values (PPVs) for either previous or active infection with Borrelia burgdorferi s.l. were calculated for different cut-off ELISA IgG antibody levels where the immunoblot was regarded as reference test. In total, 1454 patients were included. According to the two-step test strategy, 486 (33%), 69 (5%) and 899 (62%) patients had positive, indeterminate and negative Borrelia IgG serology, respectively. At IgG levels of 500 IU/ml and higher, all immunoblots were positive, resulting in a 100% PPV (95% CI: 97.0-100). At IgG levels of 200 IU/ml and higher, the PPV was 99.3% (95% CI: 97.4-99.8). In conclusion, at IgG levels of 200 IU/ml and higher, an ELISA was sufficient to detect antibodies to Borrelia burgdorferi s.l. At those IgG levels, a confirmatory immunoblot may be omitted in patients referred to a tertiary Lyme centre. Before these results can be implemented in routine diagnosis of Lyme borreliosis, confirmation of the results is necessary in other patient populations and using other quantitative ELISAs and immunoblots. Copyright © 2017 Elsevier GmbH. All rights reserved.
Mertens, Melanie; Brehler, Randolf
2011-01-01
In hymenoptera venom allergy, about 75% of detected in vitro double positivity to yellow jacket and honeybee venom is ascribed to specific IgE (sIgE) directed against cross-reactive carbohydrate determinants (CCDs). To date, for the detection of CCD-sIgE, different carbohydrate antigens and methods are used. The most suitable one still has to be identified. Eighty-seven patients with confirmed hymenoptera venom allergy and venom sIgE values of ≥0.7 kU/l were investigated. Sixty-five patients showed sIgE reactivity to both yellow jacket and honeybee venom, 22 were venom mono positive and served as controls. Occurrence of CCD-sIgE was determined using bromelain, horseradish peroxidase (HRP) and MUXF(3) on system A, and ascorbic acid oxidase (AAO), bromelain and HRP on system B. Further, a reference standard for CCD-sIgE evaluation was created: CCD positivity was assumed when at least 4 of the 6 test results were positive. According to the defined reference standard, 45/65 venom double positive patients exhibited CCD-sIgE. Using system A, comparison with the reference standard revealed sensitivity and specificity values of 96 and 97%, respectively, for MUXF(3), 100 and 100%, respectively, for bromelain, and 96 and 97%, respectively, for HRP. Using system B, sensitivity and specificity was 98 and 97%, respectively, for AAO, 62 and 95%, respectively, for bromelain, and 96 and 69%, respectively, for HRP. Results of the 3 test allergens obtained with system A showed strong correlations (r = 0.932-0.976), whereas results with system B showed lower correlations (r = 0.714-0.898). All 3 test allergens used with system A are suitable for CCD-sIgE detection in hymenoptera venom allergy. With system B, only AAO seems to be a reliable tool. Copyright © 2011 S. Karger AG, Basel.
NoWMex: Continuous GNSS Sites in Northwest Mexico
NASA Astrophysics Data System (ADS)
Gonzalez-Garcia, J. J.; Gonzalez-Ortega, J. A.
2008-05-01
Nowadays GPS has become part of daily life activities. In the near future, with the GPS modernization and the use of Glonass and Galileo as a Global Navigation Satellite System will give relative location precision from decimeters to millimeters in near real time applications. In order to realize this, we need a global array of continuously operating GNSS stations built to meet the standards of the geophysical communities and linked with gravimetric local measurements to discern the vertical component of our active Earth. Trying to follow this revolution, CICESE has been working with GPS since 1985. The GPS site CICE was built as an IGS reference station in 1995. Afterward we built 5 more continuous GPS sites in Northwest Mexico with the support of SCIGN. The CGPS NoWMex network is currently made up of six sites: CIC1, SPMX, CORX, GUAX, USMX and YESX (sopac.ucsd.edu). Recently, we implemented an experimental GPS processing lab as part of the Geodesy and Geodynamics Laboratory in the Seismology Department at CICESE. 30 stations are now currently processed from the network Red Geodesica Nacional Activa (RGNA-INEGI), NoWMex, and sites in neighbor countries. Fiducials solutions in ITRF2000 are obtained using GAMIT/GLOBK 10.31 with final igs orbits, every month since 2006. In order to make a contribution to densification of ITRF and support NAREF, SIRGAS and SNARF issues related to scientific and geomatics results; we are looking for internal (Mexican) and external colleagues as well as funding for maintenance and increase the number of CGNSS in NoWMeX including southern Basin and Ranger (Sonora, Chihuahua, Sinaloa and Durango), Gulf of California islands, Peninsular Californias, Nayarit, Jalisco, Colima and the Mexican Pacific islands: Guadalupe (2 more sites), Cedros, Socorro (DORIS site), Clarion and Tres Marias. We must to build more and free available CGNSS sites in and around Mexico to contribute to sea level rise and global change studies.
Geomagnetic Storm Impact On GPS Code Positioning
NASA Astrophysics Data System (ADS)
Uray, Fırat; Varlık, Abdullah; Kalaycı, İbrahim; Öǧütcü, Sermet
2017-04-01
This paper deals with the geomagnetic storm impact on GPS code processing with using GIPSY/OASIS research software. 12 IGS stations in mid-latitude were chosen to conduct the experiment. These IGS stations were classified as non-cross correlation receiver reporting P1 and P2 (NONCC-P1P2), non-cross correlation receiver reporting C1 and P2 (NONCC-C1P2) and cross-correlation (CC-C1P2) receiver. In order to keep the code processing consistency between the classified receivers, only P2 code observations from the GPS satellites were processed. Four extreme geomagnetic storms October 2003, day of the year (DOY), 29, 30 Halloween Storm, November 2003, DOY 20, November 2004, DOY 08 and four geomagnetic quiet days in 2005 (DOY 92, 98, 99, 100) were chosen for this study. 24-hour rinex data of the IGS stations were processed epoch-by-epoch basis. In this way, receiver clock and Earth Centered Earth Fixed (ECEF) Cartesian Coordinates were solved for a per-epoch basis for each day. IGS combined broadcast ephemeris file (brdc) were used to partly compensate the ionospheric effect on the P2 code observations. There is no tropospheric model was used for the processing. Jet Propulsion Laboratory Application Technology Satellites (JPL ATS) computed coordinates of the stations were taken as true coordinates. The differences of the computed ECEF coordinates and assumed true coordinates were resolved to topocentric coordinates (north, east, up). Root mean square (RMS) errors for each component were calculated for each day. The results show that two-dimensional and vertical accuracy decreases significantly during the geomagnetic storm days comparing with the geomagnetic quiet days. It is observed that vertical accuracy is much more affected than the horizontal accuracy by geomagnetic storm. Up to 50 meters error in vertical component has been observed in geomagnetic storm day. It is also observed that performance of Klobuchar ionospheric correction parameters during geomagnetic storm days cannot guarantee the improving accuracy due to the ionospheric scintillation.
ERP-Variations on Time Scales Between Hours and Months Derived From GNSS Observations
NASA Astrophysics Data System (ADS)
Weber, R.; Englich, S.; Mendes Cerveira, P.
2007-05-01
Current observations gained by the space geodetic techniques, especially VLBI, GPS and SLR, allow for the determination of Earth Rotation Parameters (ERPs - polar motion, UT1/LOD) with unprecedented accuracy and temporal resolution. This presentation focuses on contributions to the ERP recovery provided by satellite navigation systems (primarily GPS). The IGS (International GNSS Service), for example, currently provides daily polar motion with an accuracy of less than 0.1mas and LOD estimates with an accuracy of a few microseconds. To study more rapid variations in polar motion and LOD we established in a first step a high resolution (hourly resolution) ERP-time series from GPS observation data of the IGS network covering the year 2005. The calculations were carried out by means of the Bernese GPS Software V5.0 considering observations from a subset of 113 fairly stable stations out of the IGS05 reference frame sites. From these ERP time series the amplitudes of the major diurnal and semidiurnal variations caused by ocean tides are estimated. After correcting the series for ocean tides the remaining geodetic observed excitation is compared with variations of atmospheric excitation (AAM). To study the sensitivity of the estimates with respect to the applied mapping function we applied both the widely used NMF (Niell Mapping Function) and the VMF1 (Vienna Mapping Function 1). In addition, based on computations covering two months in 2005, the potential improvement due to the use of additional GLONASS data will be discussed.
Precise Point Positioning Using Triple GNSS Constellations in Various Modes
Afifi, Akram; El-Rabbany, Ahmed
2016-01-01
This paper introduces a new dual-frequency precise point positioning (PPP) model, which combines the observations from three different global navigation satellite system (GNSS) constellations, namely GPS, Galileo, and BeiDou. Combining measurements from different GNSS systems introduces additional biases, including inter-system bias and hardware delays, which require rigorous modelling. Our model is based on the un-differenced and between-satellite single-difference (BSSD) linear combinations. BSSD linear combination cancels out some receiver-related biases, including receiver clock error and non-zero initial phase bias of the receiver oscillator. Forming the BSSD linear combination requires a reference satellite, which can be selected from any of the GPS, Galileo, and BeiDou systems. In this paper three BSSD scenarios are tested; each considers a reference satellite from a different GNSS constellation. Natural Resources Canada’s GPSPace PPP software is modified to enable a combined GPS, Galileo, and BeiDou PPP solution and to handle the newly introduced biases. A total of four data sets collected at four different IGS stations are processed to verify the developed PPP model. Precise satellite orbit and clock products from the International GNSS Service Multi-GNSS Experiment (IGS-MGEX) network are used to correct the GPS, Galileo, and BeiDou measurements in the post-processing PPP mode. A real-time PPP solution is also obtained, which is referred to as RT-PPP in the sequel, through the use of the IGS real-time service (RTS) for satellite orbit and clock corrections. However, only GPS and Galileo observations are used for the RT-PPP solution, as the RTS-IGS satellite products are not presently available for BeiDou system. All post-processed and real-time PPP solutions are compared with the traditional un-differenced GPS-only counterparts. It is shown that combining the GPS, Galileo, and BeiDou observations in the post-processing mode improves the PPP convergence time by 25% compared with the GPS-only counterpart, regardless of the linear combination used. The use of BSSD linear combination improves the precision of the estimated positioning parameters by about 25% in comparison with the GPS-only PPP solution. Additionally, the solution convergence time is reduced to 10 minutes for the BSSD model, which represents about 50% reduction, in comparison with the GPS-only PPP solution. The GNSS RT-PPP solution, on the other hand, shows a similar convergence time and precision to the GPS-only counterpart. PMID:27240376
Precise Point Positioning Using Triple GNSS Constellations in Various Modes.
Afifi, Akram; El-Rabbany, Ahmed
2016-05-28
This paper introduces a new dual-frequency precise point positioning (PPP) model, which combines the observations from three different global navigation satellite system (GNSS) constellations, namely GPS, Galileo, and BeiDou. Combining measurements from different GNSS systems introduces additional biases, including inter-system bias and hardware delays, which require rigorous modelling. Our model is based on the un-differenced and between-satellite single-difference (BSSD) linear combinations. BSSD linear combination cancels out some receiver-related biases, including receiver clock error and non-zero initial phase bias of the receiver oscillator. Forming the BSSD linear combination requires a reference satellite, which can be selected from any of the GPS, Galileo, and BeiDou systems. In this paper three BSSD scenarios are tested; each considers a reference satellite from a different GNSS constellation. Natural Resources Canada's GPSPace PPP software is modified to enable a combined GPS, Galileo, and BeiDou PPP solution and to handle the newly introduced biases. A total of four data sets collected at four different IGS stations are processed to verify the developed PPP model. Precise satellite orbit and clock products from the International GNSS Service Multi-GNSS Experiment (IGS-MGEX) network are used to correct the GPS, Galileo, and BeiDou measurements in the post-processing PPP mode. A real-time PPP solution is also obtained, which is referred to as RT-PPP in the sequel, through the use of the IGS real-time service (RTS) for satellite orbit and clock corrections. However, only GPS and Galileo observations are used for the RT-PPP solution, as the RTS-IGS satellite products are not presently available for BeiDou system. All post-processed and real-time PPP solutions are compared with the traditional un-differenced GPS-only counterparts. It is shown that combining the GPS, Galileo, and BeiDou observations in the post-processing mode improves the PPP convergence time by 25% compared with the GPS-only counterpart, regardless of the linear combination used. The use of BSSD linear combination improves the precision of the estimated positioning parameters by about 25% in comparison with the GPS-only PPP solution. Additionally, the solution convergence time is reduced to 10 minutes for the BSSD model, which represents about 50% reduction, in comparison with the GPS-only PPP solution. The GNSS RT-PPP solution, on the other hand, shows a similar convergence time and precision to the GPS-only counterpart.
Altrich, Michelle L.; Nowicki, Marek J.
2016-01-01
The identification of nearly 3,500 cases of chikungunya virus (CHIKV) infection in U.S. residents returning in 2014 and 2015 from areas in which it is endemic has raised concerns within the transplant community that, should recently infected individuals become organ and/or tissue donors, CHIKV would be transmitted to transplant recipients. Thus, tests designed to detect recent CHIKV infection among U.S. organ and tissue donors may become necessary in the future. Accordingly, we evaluated 2 enzyme-linked immunosorbent assays (ELISAs) for CHIKV IgM readily available in the United States using 1,000 deidentified serum or plasma specimens collected from donors between November 2014 and March 2015. The Euroimmun indirect ELISA identified 38 reactive specimens; however, all 38 were negative for CHIKV IgG and IgM in immunofluorescence assays (IFAs) conducted at a reference laboratory and, thus, were falsely reactive in the Euroimmun CHIKV IgM assay. The InBios IgM-capture ELISA identified 26 reactive samples, and one was still reactive (index ≥ 1.00) when retested using the InBios kit with a background subtraction modification to identify false reactivity. This reactive specimen was CHIKV IgM negative but IgG positive by IFAs at two reference laboratories; plaque reduction neutralization testing (PRNT) demonstrated CHIKV-specific reactivity. The IgG and PRNT findings strongly suggest that the InBios CHIKV IgM-reactive result represents true reactivity, even though the IgM IFA result was negative. If testing organ/tissue donors for CHIKV IgM becomes necessary, the limitations of the currently available CHIKV IgM ELISAs and options for their optimization must be understood to avoid organ/tissue wastage due to falsely reactive results. PMID:27535838
Sakaguchi, Kazuhiko; Hirota, Yushi; Hashimoto, Naoko; Ogawa, Wataru; Sato, Toshiyuki; Okada, Seiki; Hagino, Kei; Asakura, Yoshihiro; Kikkawa, Yasuo; Kojima, Junko; Maekawa, Yasunori; Nakajima, Hiromu
2012-06-01
Recent studies have highlighted the importance of managing postprandial hyperglycemia, but adequate monitoring of postprandial glucose remains difficult because of wide variations in levels. We have therefore developed a minimally invasive system to monitor postprandial glucose area under the curve (AUC). This system involves no blood sampling and uses interstitial fluid glucose (IG) AUC (IG-AUC) as a surrogate marker of postprandial glucose. This study aimed to evaluate the usefulness of this system by comparing data with the findings of oral glucose tolerance tests (OGTTs) in subjects with and without diabetes. The glucose AUC monitoring system was validated by OGTTs in 37 subjects with and 10 subjects without diabetes. A plastic microneedle array was stamped on the forearm to extract IG. A hydrogel patch was then placed on the pretreated area to accumulate IG. Glucose and sodium ion concentrations in the hydrogel were measured to calculate IG-AUC at 2-h postload glucose. Plasma glucose (PG) levels were measured every 30 min to calculate reference PG-AUC. IG-AUC correlated strongly with reference PG-AUC (r=0.93) over a wide range. The level of correlation between IG-AUC and maximum PG level was also high (r=0.86). The painless nature of the technique was confirmed by the response of patients to questionnaires. The glucose AUC monitoring system using IG provided good estimates of reference PG-AUC and maximum PG level during OGTTs in subjects with and without diabetes. This system provides easy-to-use monitoring of glucose AUC, which is a good indicator of postprandial glucose.
Trotta, Michele; Borchi, Beatrice; Zammarchi, Lorenzo; Sterrantino, Gaetana; Brogi, Michela; Kiros, Seble Tekle; Lorini, Chiara; Bonaccorsi, Guglielmo; Colao, Maria Grazia; Bartoloni, Alessandro
2016-12-01
The aim of this study was to evaluate immunoglobulin M indirect-fluorescent antibody test (IgM IFAT) for the diagnosis of acute or chronic Toxoplasma infection in pregnancy. Pregnant women with suspected acute toxoplasmosis referred to the Tuscany Reference Center for Infectious Diseases in Pregnancy during the period 1998-2012 were retrospectively enrolled. All women were tested with a panel of serological tests, including enzyme-linked immunosorbent assay for IgG avidity and IgM IFAT. On the basis of anamnestic, clinical, and serological criteria, pregnant women were classified into three groups: recently infected (RI), latently infected (LI), and doubtful latently infected (DLI). Patients classified as DLI were excluded from the analysis. The association between IgM IFAT (positive or negative) and the diagnosis of infection (acute or chronic) was assessed. Positive predictive value and negative predictive value of the IgM IFAT were calculated. A total of 810 pregnant women were enrolled in the study: 302 in the RI group and 508 in the LI group. Fifty-two women classified as DLI were excluded. IgM IFAT was positive in 172 out of 302 (56.9%) pregnant women in the RI group and in 29 out of 508 (5.7%) in the LI group. The positive predictive value and negative predictive value of IgM IFAT in predicting RI was 85.6% and 78.6%, respectively. IgM IFAT has reasonable sensitivity and specificity in diagnosing recent infection and, mostly in case of borderline avidity test, could be considered as a further aid for an accurate diagnosis of acute toxoplasmosis in pregnancy. © 2016 Japan Society of Obstetrics and Gynecology.
Sadaghian, Mohammad; Amani, Sasan; Jafari, Rasool
2016-06-01
Toxoplasmosis is mostly asymptomatic infection in immunocompetent individuals while it can cause a severe infection in human fetus during pregnancy and immunocompromised patients. This study aimed to determine the prevalence of anti-Toxoplasma IgM and IgG seropositivity and potential risk factors of the infection in humans referred to Urmia City main diagnostic laboratories, Urmia, Iran. Totally 195 blood samples were collected from the individuals referred to main diagnostic laboratories of Urmia City, 2013. Serum concentration of anti-Toxoplasma IgG and IgM were determined using ELISA method. Demographic variables of the participants were collected by interviewing, which are including sex, age, occupation, educational and residential status, eating undercooked meat, consumption of raw vegetable and the method of washing raw vegetables. None of all 200 serum sample were anti-Toxoplasma IgM positive, but different concentrations of anti-Toxoplasma IgG were observed in 88 (45.12 %) of samples. The significant higher rate of anti-Toxoplasma IgG seropositivity were observed in people with soil related jobs (P = 0.005, OR = 2.266; 95 % CI 1.260, 4.078) and history of eating raw vegetables at restaurant (P = 0.036, OR = 1.985; 95 % CI 0.991, 3.978). Also anti-Toxoplasma IgG concentration mean was significantly higher in people who were commonly eaten raw vegetable at restaurants (P < 0.001, t = 7.918). The prevalence of chronic toxoplasmosis is considerably high while the acute infection is very low in the studied area. Having soil related jobs and eating raw vegetables at restaurants increases the risk of acquiring the infection.
Acute suppression of serum IgM and IgA in tank workers exposed to benzene.
Kirkeleit, J; Ulvestad, E; Riise, T; Bråtveit, M; Moen, B E
2006-12-01
We investigated associations between benzene exposure and alterations of proteins and cells of the immune system among workers maintaining cargo tanks containing crude oil residues. Individual exposure to benzene, benzene in blood and urine, peripheral blood lymphocytes (total lymphocytes, lymphocytes in subpopulations CD3, CD4, CD8, CD19, CD56 and CD4/CD8 ratio), complement factors C3 and C4 and serum concentration of immunoglobulins (IgG, IgA, IgM and IgE) were analysed among 13 tank workers and nine unexposed referents (catering section). Benzene exposure was measured during three consecutive 12-h work days. Blood and urine samples were collected pre-shift on the first day (baseline), post-shift on the third day, and pre-next shift on the following morning. The time spent in the cargo tank was logged. The individual geometric mean benzene exposure in the breathing zone of tank workers over 3 days was 0.15 p.p.m. (range 0.01-0.62 p.p.m.) (n = 26). The geometric mean benzene concentration in blood post-shift was 12.3 nmol/l among tank workers versus 0.7 nmol/l among the referents. Tank workers showed a decline (versus referents) in IgM from baseline to post-shift (t-test, P = 0.04) and IgA from baseline to pre-next shift (t-test, P = 0.01). They also showed a decline in CD4 T cells from baseline to post-shift (t-test, P = 0.04). Suppression correlated with benzene exposure, benzene concentrations in blood and urine and time spent in the tank. The groups did not differ significantly in the change in other immune parameters. The clinical significance is unknown and warrants further studies.
Analysis of Site Position Time Series Derived From Space Geodetic Solutions
NASA Astrophysics Data System (ADS)
Angermann, D.; Meisel, B.; Kruegel, M.; Tesmer, V.; Miller, R.; Drewes, H.
2003-12-01
This presentation deals with the analysis of station coordinate time series obtained from VLBI, SLR, GPS and DORIS solutions. We also present time series for the origin and scale derived from these solutions and discuss their contribution to the realization of the terrestrial reference frame. For these investigations we used SLR and VLBI solutions computed at DGFI with the software systems DOGS (SLR) and OCCAM (VLBI). The GPS and DORIS time series were obtained from weekly station coordinates solutions provided by the IGS, and from the joint DORIS analysis center (IGN-JPL). We analysed the time series with respect to various aspects, such as non-linear motions, periodic signals and systematic differences (biases). A major focus is on a comparison of the results at co-location sites in order to identify technique- and/or solution related problems. This may also help to separate and quantify possible effects, and to understand the origin of still existing discrepancies. Technique-related systematic effects (biases) should be reduced to the highest possible extent, before using the space geodetic solutions for a geophysical interpretation of seasonal signals in site position time series.
Study of the active deformation of Mitidja (Tell Atlas, Algeria) by GPS
NASA Astrophysics Data System (ADS)
Bacha, Wahab; Masson, Frederic; Yelles-Chaouche, Abdelkrim; Lammali, Kamel; Bellik, Amar; Hamai, Lamine
2013-04-01
A network was created in the Mitidja region around the capital Algiers (Algeria). It has been established to study the deformation of the region and the slow operation of flaws in it. The network was installed by a distribution of GPS stations according to structural domains existing in the region. Twelve bases spread across the study area, have been installed. The measurements were acquired by performing four measurement campaigns in 2006, 2007, 2009 and 2010, with sessions over a month of action. This work allowed the installation of a geodetic network of regional monitoring by methodology GPS in the zone of Mitidja (Tellian Atlas, Algeria). Four observation campaigns were carried out on this area with session's superiors in one month of measurements. The treatment was carried out with software GAMIT-GLOBK, the network is attached to several world stations IGS treated between 2000-2010, indexed in a precise frame of reference ITRF05. The results presented in this memory show a deformation in shortening ≤ 0.5 mm/an in the plain of Mitidja and the surrounding Solid masses.
Stirnemann, J J; Fries, N; Bessis, R; Fontanges, M; Mangione, R; Salomon, L J
2017-04-01
To assess potential differences in fetal size between the French population and the international population from the INTERGROWTH-21 st (IG-21 st ) Project and to measure the impact of switching to the IG-21 st reference standards for fetal size. This was a nationwide cross-sectional study of fetal ultrasound biometry. Low-risk singleton pregnancies were recruited prospectively within the network of the national French College of Fetal Ultrasound, CFEF, over a 6-week period. Further selection was performed based on the criteria of the IG-21 st Project in order to obtain a comparable population. Head circumference (HC) was used as the main fat-free skeletal measure of growth for comparison of French fetal size with that of the IG-21 st population. The impact of switching to the IG-21 st fetal growth standards was quantified by comparing Z-scores calculated using the IG-21 st standards with those calculated using locally derived reference ranges for HC, abdominal circumference (AC) and femur length (FL). Following selection, 4858 cases were analyzed. The distribution of HC demonstrated clear similarity between our French population and the IG-21 st population: our observed centile curves closely matched those of IG-21 st and the Z-scores were close to 0 across gestational age. The IG-21 st standards performed as well as did locally derived charts in terms of screening for small-for-gestational age by AC, while they identified significantly fewer small FL values than were expected and than did the locally derived charts. Under strict selection criteria, fetal size in France is similar to that of the international population used in the IG-21 st Project. The discrepancies in FL are unlikely to impact on prenatal management. Therefore, switching from locally derived reference ranges to the IG-21 st standards appears to be a safe option. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
A new gene in A. rubens: A sea star Ig kappa gene.
Vincent, Nadine; Osteras, Magne; Otten, Patricia; Leclerc, Michel
2014-12-01
The sea star Asterias rubens reacts specifically to the antigen:HRP (horse-radish peroxydase) and produces an antibody anti-HRP. We previously identified a candidate Ig kappa gene corresponding to this manuscript. We show now the gene referred to as: "sea star Ig kappa gene in its specificity".
Olariu, Tudor Rares; Remington, Jack S; McLeod, Rima; Alam, Ambereen; Montoya, Jose G
2011-12-01
Congenital toxoplasmosis can cause significant neurologic manifestations and other untoward sequelae. The Palo Alto Medical Foundation Toxoplasma Serology Laboratory database was searched for data on infants 0 to 180 days old, in whom congenital toxoplasmosis had been confirmed and who had been tested for Toxoplasma gondii-specific immunoglobulin G (IgG), IgM, and IgA antibodies, between 1991 and 2005. Their clinical findings were confirmed at the National Collaborative Chicago-based Congenital Toxoplasmosis Study center. We reviewed available clinical data and laboratory profiles of 164 infants with congenital toxoplasmosis whose mothers had not been treated for the parasite during gestation. One or more severe clinical manifestations of congenital toxoplasmosis were reported in 84% of the infants and included eye disease (92.2%), brain calcifications (79.6%), and hydrocephalus (67.7%). In 61.6% of the infants, eye disease, brain calcifications, and hydrocephalus were present concurrently. T. gondii-specific IgM, IgA, and IgE antibodies were demonstrable in 86.6%, 77.4%, and 40.2% of the infants, respectively. Testing for IgM and IgA antibodies increased the sensitivity of making the diagnosis of congenital toxoplasmosis to 93% compared with testing for IgM or IgA individually. IgM and IgA antibodies were still present in 43.9% of infants diagnosed between 1 and 6 months of life. Our study reveals that severe clinical signs of congenital toxoplasmosis including hydrocephalus, eye disease, or intracranial calcifications occurred in 85% infants whose sera were referred to our reference Toxoplasma Serology Laboratory during a period of 15 years. Laboratory tests, including serologic and polymerase chain reaction tests, were critical for diagnosis in the infants. Our results contrast remarkably with those of European investigators who rarely observe severe clinical signs in infants with congenital toxoplasmosis.
Serologic Tests of IgG and IgM Antibodies and IgG Avidity for Diagnosis of Ocular Toxoplasmosis.
Rahimi-Esboei, Bahman; Zarei, Mohammad; Mohebali, Mehdi; Valian, Hossein Keshavarz; Shojaee, Saeedeh; Mahmoudzadeh, Raziyeh; Salabati, Mirataollah
2018-04-01
This prospective study was aimed to detect acute and chronic ocular toxoplasmosis by comparison of anti- Toxoplasma gondii IgM and IgG antibody levels and IgG avidity test. One hundred and seventeen patients with ocular toxoplasmosis (OT) who referred to the Farabi Eye Hospital, Tehran, Iran were included in this study. Of the patients, 77 cases were positive for anti- T. gondii IgG, and 8 cases were positive for anti- T. gondii IgM. IgG avidity test revealed 11, 4, and 102 cases were low, intermediate, and high, respectively, and 6.8% and 9.4% of cases were positive for IgM and IgG avidity tests, respectively ( P =0.632). Agreement (Kappa value) between paired tests IgG-IgM, IgG-IgG avidity, and IgM-IgG avidity was 0.080, 0.099, and 0.721, respectively ( P <0.05). This study showed that conventional serologic tests (IgM and IgG levels) and IgG avidity correlate well each other and can be used to differentiate recent infections from old OT. It seems that reactivated old infections rather than recently acquired infections are majority of Iranian OT patients.
NASA Astrophysics Data System (ADS)
Gruszczynska, Marta; Rosat, Severine; Klos, Anna; Bogusz, Janusz
2017-04-01
Seasonal oscillations in the GPS position time series can arise from real geophysical effects and numerical artefacts. According to Dong et al. (2002) environmental loading effects can account for approximately 40% of the total variance of the annual signals in GPS time series, however using generally acknowledged methods (e.g. Least Squares Estimation, Wavelet Decomposition, Singular Spectrum Analysis) to model seasonal signals we are not able to separate real from spurious signals (effects of mismodelling aliased into annual period as well as draconitic). Therefore, we propose to use Multichannel Singular Spectrum Analysis (MSSA) to determine seasonal oscillations (with annual and semi-annual periods) from GPS position time series and environmental loading displacement models. The MSSA approach is an extension of the classical Karhunen-Loève method and it is a special case of SSA for multivariate time series. The main advantage of MSSA is the possibility to extract common seasonal signals for stations from selected area and to investigate the causality between a set of time series as well. In this research, we explored the ability of MSSA application to separate real geophysical effects from spurious effects in GPS time series. For this purpose, we used GPS position changes and environmental loading models. We analysed the topocentric time series from 250 selected stations located worldwide, delivered from Network Solution obtained by the International GNSS Service (IGS) as a contribution to the latest realization of the International Terrestrial Reference System (namely ITRF2014, Rebishung et al., 2016). We also researched atmospheric, hydrological and non-tidal oceanic loading models provided by the EOST/IPGS Loading Service in the Centre-of-Figure (CF) reference frame. The analysed displacements were estimated from ERA-Interim (surface pressure), MERRA-land (soil moisture and snow) as well as ECCO2 ocean bottom pressure. We used Multichannel Singular Spectrum Analysis to determine common seasonal signals in two case studies with adopted a 3-years lag-window as the optimal window size. We also inferred the statistical significance of oscillations through the Monte Carlo MSSA method (Allen and Robertson, 1996). In the first case study, we investigated the common spatio-temporal seasonal signals for all stations. For this purpose, we divided selected stations with respect to the continents. For instance, for stations located in Europe, seasonal oscillations accounts for approximately 45% of the GPS-derived data variance. Much higher variance of seasonal signals is explained by hydrological loadings of about 92%, while the non-tidal oceanic loading accounted for 31% of total variance. In the second case study, we analysed the capability of the MSSA method to establish a causality between several time series. Each of estimated Principal Component represents pattern of the common signal for all analysed data. For ZIMM station (Zimmerwald, Switzerland), the 1st, 2nd and 9th, 10th Principal Components, which accounts for 35% of the variance, corresponds to the annual and semi-annual signals. In this part, we applied the non-parametric MSSA approach to extract the common seasonal signals for GPS time series and environmental loadings for each of the 250 stations with clear statement, that some part of seasonal signal reflects the real geophysical effects. REFERENCES: 1. Allen, M. and Robertson, A.: 1996, Distinguishing modulated oscillations from coloured noise in multivariate datasets. Climate Dynamics, 12, No. 11, 775-784. DOI: 10.1007/s003820050142. 2. Dong, D., Fang, P., Bock, Y., Cheng, M.K. and Miyazaki, S.: 2002, Anatomy of apparent seasonal variations from GPS-derived site position time series. Journal of Geophysical Research, 107, No. B4, 2075. DOI: 10.1029/2001JB000573. 3. Rebischung, P., Altamimi, Z., Ray, J. and Garayt, B.: 2016, The IGS contribution to ITRF2014. Journal of Geodesy, 90, No. 7, 611-630. DOI:10.1007/s00190-016-0897-6.
The International GPS Service (IGS) as a Continuous Reference System for Precise GPS Positioning
NASA Technical Reports Server (NTRS)
Neilan, Ruth; Heflin, Michael; Watkins, Michael; Zumberge, James
1996-01-01
The International GPS Service for Geodynamics (IGS) is an organization which operates under the auspices of the International Association of Geodesy (IAG) and has been operational since January 1994. The primary objective of the IGS is to provide precise GPS data and data products to support geodetic and geophysical research activities.
NASA Astrophysics Data System (ADS)
Yildirim, Omer; Inyurt, Samed; Mekik, Cetin
2016-02-01
Turkey is a country located in the middle latitude zone, where tectonic activity is intensive. Recently, an earthquake of magnitude 6.5 Mw occurred offshore in the Aegean Sea on 24 May 2014 at 09:25 UTC, which lasted about 40 s. The earthquake was also felt in Greece, Romania, and Bulgaria in addition to Turkey. In recent years, ionospheric anomaly detection studies have been carried out because of seismicity with total electron content (TEC) computed from the global navigation satellite system's (GNSS) signal delays and several interesting findings have been published. In this study, both TEC and positional variations have been examined separately following a moderate size earthquake in the Aegean Sea. The correlation of the aforementioned ionospheric variation with the positional variation has also been investigated. For this purpose, a total of 15 stations was used, including four continuously operating reference stations in Turkey (CORS-TR) and stations in the seismic zone (AYVL, CANA, IPSA, and YENC), as well as international GNSS service (IGS) and European reference frame permanent network (EPN) stations. The ionospheric and positional variations of the AYVL, CANA, IPSA, and YENC stations were examined using Bernese v5.0 software. When the precise point positioning TEC (PPP-TEC) values were examined, it was observed that the TEC values were approximately 4 TECU (total electron content unit) above the upper-limit TEC value at four stations located in Turkey, 3 days before the earthquake at 08:00 and 10:00 UTC. At the same stations, on the day before the earthquake at 06:00, 08:00, and 10:00 UTC, the TEC values were approximately 5 TECU below the lower-limit TEC value. The global ionosphere model TEC (GIM-TEC) values published by the Centre for Orbit Determination in Europe (CODE) were also examined. Three days before the earthquake, at all stations, it was observed that the TEC values in the time period between 08:00 and 10:00 UTC were approximately 2 TECU above the upper-limit TEC value; 1 day before the earthquake at 06:00, 08:00, and 10:00 UTC, the TEC values were approximately 4 TECU below the lower-limit TEC value. Again, by using the same 15 stations, positional variation investigation for before and after the earthquake was undertaken for the AYVL, CANA, IPSA, and YENC stations. As a result of the conducted analysis, positional displacements were seen before and after the earthquake at the CANA station, which is the nearest station to the earthquake centre. Before and after the earthquake, positional displacements were observed as 10 and 3 cm respectively.
Data Assimilation and Adjusted Spherical Harmonic Model of VTEC Map over Thailand
NASA Astrophysics Data System (ADS)
Klinngam, Somjai; Maruyama, Takashi; Tsugawa, Takuya; Ishii, Mamoru; Supnithi, Pornchai; Chiablaem, Athiwat
2016-07-01
The global navigation satellite system (GNSS) and high frequency (HF) communication are vulnerable to the ionospheric irregularities, especially when the signal travels through the low-latitude region and around the magnetic equator known as equatorial ionization anomaly (EIA) region. In order to study the ionospheric effects to the communications performance in this region, the regional map of the observed total electron content (TEC) can show the characteristic and irregularities of the ionosphere. In this work, we develop the two-dimensional (2D) map of vertical TEC (VTEC) over Thailand using the adjusted spherical harmonic model (ASHM) and the data assimilation technique. We calculate the VTEC from the receiver independent exchange (RINEX) files recorded by the dual-frequency global positioning system (GPS) receivers on July 8th, 2012 (quiet day) at 12 stations around Thailand: 0° to 25°E and 95°N to 110°N. These stations are managed by Department of Public Works and Town & Country Planning (DPT), Thailand, and the South East Asia Low-latitude ionospheric Network (SEALION) project operated by National Institute of Information and Communications Technology (NICT), Japan, and King Mongkut's Institute of Technology Ladkrabang (KMITL). We compute the median observed VTEC (OBS-VTEC) in the grids with the spatial resolution of 2.5°x5° in latitude and longitude and time resolution of 2 hours. We assimilate the OBS-VTEC with the estimated VTEC from the International Reference Ionosphere model (IRI-VTEC) as well as the ionosphere map exchange (IONEX) files provided by the International GNSS Service (IGS-VTEC). The results show that the estimation of the 15-degree ASHM can be improved when both of IRI-VTEC and IGS-VTEC are weighted by the latitude-dependent factors before assimilating with the OBS-VTEC. However, the IRI-VTEC assimilation can improve the ASHM estimation more than the IGS-VTEC assimilation. Acknowledgment: This work is partially funded by the Ministry of Science and Technology of Thailand and King Mongkut's Institute of Technology Ladkrabang under grant no. A118-59-011.
Impact of selected troposphere models on Precise Point Positioning convergence
NASA Astrophysics Data System (ADS)
Kalita, Jakub; Rzepecka, Zofia
2016-04-01
The Precise Point Positioning (PPP) absolute method is currently intensively investigated in order to reach fast convergence time. Among various sources that influence the convergence of the PPP, the tropospheric delay is one of the most important. Numerous models of tropospheric delay are developed and applied to PPP processing. However, with rare exceptions, the quality of those models does not allow fixing the zenith path delay tropospheric parameter, leaving difference between nominal and final value to the estimation process. Here we present comparison of several PPP result sets, each of which based on different troposphere model. The respective nominal values are adopted from models: VMF1, GPT2w, MOPS and ZERO-WET. The PPP solution admitted as reference is based on the final troposphere product from the International GNSS Service (IGS). The VMF1 mapping function was used for all processing variants in order to provide capability to compare impact of applied nominal values. The worst case initiates zenith wet delay with zero value (ZERO-WET). Impact from all possible models for tropospheric nominal values should fit inside both IGS and ZERO-WET border variants. The analysis is based on data from seven IGS stations located in mid-latitude European region from year 2014. For the purpose of this study several days with the most active troposphere were selected for each of the station. All the PPP solutions were determined using gLAB open-source software, with the Kalman filter implemented independently by the authors of this work. The processing was performed on 1 hour slices of observation data. In addition to the analysis of the output processing files, the presented study contains detailed analysis of the tropospheric conditions for the selected data. The overall results show that for the height component the VMF1 model outperforms GPT2w and MOPS by 35-40% and ZERO-WET variant by 150%. In most of the cases all solutions converge to the same values during first hour of processing. Finally, the results have been compared against results obtained during calm tropospheric conditions.
Prince, Harry E; Altrich, Michelle L; Nowicki, Marek J
2016-10-01
The identification of nearly 3,500 cases of chikungunya virus (CHIKV) infection in U.S. residents returning in 2014 and 2015 from areas in which it is endemic has raised concerns within the transplant community that, should recently infected individuals become organ and/or tissue donors, CHIKV would be transmitted to transplant recipients. Thus, tests designed to detect recent CHIKV infection among U.S. organ and tissue donors may become necessary in the future. Accordingly, we evaluated 2 enzyme-linked immunosorbent assays (ELISAs) for CHIKV IgM readily available in the United States using 1,000 deidentified serum or plasma specimens collected from donors between November 2014 and March 2015. The Euroimmun indirect ELISA identified 38 reactive specimens; however, all 38 were negative for CHIKV IgG and IgM in immunofluorescence assays (IFAs) conducted at a reference laboratory and, thus, were falsely reactive in the Euroimmun CHIKV IgM assay. The InBios IgM-capture ELISA identified 26 reactive samples, and one was still reactive (index ≥ 1.00) when retested using the InBios kit with a background subtraction modification to identify false reactivity. This reactive specimen was CHIKV IgM negative but IgG positive by IFAs at two reference laboratories; plaque reduction neutralization testing (PRNT) demonstrated CHIKV-specific reactivity. The IgG and PRNT findings strongly suggest that the InBios CHIKV IgM-reactive result represents true reactivity, even though the IgM IFA result was negative. If testing organ/tissue donors for CHIKV IgM becomes necessary, the limitations of the currently available CHIKV IgM ELISAs and options for their optimization must be understood to avoid organ/tissue wastage due to falsely reactive results. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
NASA Astrophysics Data System (ADS)
Abraha, K. E.; Teferle, F. N.; Hunegnaw, A.; Woodworth, P. L.; Williams, S. D. P.; Hibbert, A.; Smalley, R., Jr.; Dalziel, I.; Lawver, L.
2017-12-01
South Georgia Island in the Southern Atlantic Ocean has been a key location for the seismic, geomagnetic and oceanic global monitoring networks. However, no permanent geodetic monitoring station had been established there despite the lack of observations from this region within, for example, the International GNSS Service (IGS) network of Global Navigation Satellite System (GNSS) stations. Then, in 2013 the King Edward Point (KEP) Geodetic Observatory was established with a focus on sea level studies and in support of general geoscience applications. Currently, this observatory located roughly half-way along the main island along its northern coastline, consists of two GNSS stations (KEPA and KRSA) with local benchmark networks, allowing the height determinations from the GNSS antennas to be transferred to the KEP tide gauge (GLOSS ID 187) and forming a height reference within the International Terrestrial Reference Frame. In late 2014, three additional GNSS stations (SG01, SG02 and SG03) were established, all located on small islands at the perimeter of the main island. Together the stations provide the best possible geographic distribution to study various geophysical processes in the region. With the GNSS-derived position time series now partly reaching over 4.5 years in length, it has become possible to provide first estimates of vertical land movements for the island and, in particular, KEP with its surrounding area. Together with four precise levelling campaigns of the benchmark network in 2013, 2014 and two in 2017, it has also been possible to investigate the very local character of the vertical motions, ie. the stability of the jetty upon which the tide gauge is mounted. Our measurements show that while South Georgia Island and the area around KEP are rising, the jetty and tide gauge are subsiding. In this study, we will present the preliminary results from the GNSS and levelling measurements and will discuss their impact on the sea level record from the KEP tide gauge which is ideally situated in a mid-ocean location for satellite altimetry calibration over the Southern Atlantic and Southern Oceans.
Genetics Home Reference: autosomal recessive hyper-IgE syndrome
... collapse boxes. Description Autosomal recessive hyper-IgE syndrome (AR-HIES) is a disorder of the immune system. ... pus (abscesses), open sores, and scaling. People with AR-HIES also tend to have frequent bouts of ...
A comparison of ITRF2014, DTRF2014 and JTRF2014 polar motion series with geophysical excitation data
NASA Astrophysics Data System (ADS)
Rebischung, Paul; Chen, Wei; Ray, Jim
2017-04-01
Three solutions were generated in response to the 2014 update by the IERS of the International Terrestrial Reference Frame: ITRF2014, the official solution from IGN; DTRF2014, from DGFI; JTRF2014, from JPL. Each incorporates essentially the same time series information of geocentric station positions + Earth rotation parameters + their associated variance-covariances from the four contributing space geodetic techniques (SLR, VLBI, DORIS, GNSS) plus local 3D vector ties (measured by conventional surveying methods) that relate a subset of co-located stations. Given the fact that measurements by all the techniques, as well as the local ties, suffer significant unmodeled systematic errors that are poorly understood, the covariance matrices are not reliable except for their geometrical aspect. So the three combination strategies differ not just in their mathematical procedures, but more importantly in how the systematic errors are handled (or not). Factors include the relative weighting of inputs, modeling of non-linear station motions, detection of time series discontinuities, etc. The final combination results therefore also differ, mostly in rather subtle ways. There are very few ways to make external evaluations of the quality of the various combinations as independent observations are generally not accurate enough. However, one approach has been shown to give useful insight by comparing the daily polar motions with geophysical excitations computed from global circulation models for atmosphere, ocean, and hydrology. J. Kouba (2010) did this for ITRF2008 and DTRF2008 and found an excess of high-frequency rotational scatter in the DGFI solution. After the development of the IGS in the 1990s, the ITRF daily polar motion accuracy has been about 30 uas or 1 mm of surface rotation. The corresponding geophysical models are not nearly so accurate but their independence does provide a valuable reference against which the geodetic results can be compared. Direct inter-comparisons of the three combined polar motion series and the IGS-only series (which predominates since 2000) already reveal interesting features: seasonal amplitudes vary markedly, up to 20 uas for the annual term in one case; differences for periods longer than monthly are greater than found in 2008; and 7-d harmonics are found in one series but not the others. We also apply the refined polar motion excitation theory of W. Chen et al. (2013), which incorporates frequency-dependent effects and updated Earth parameters, to further study the 2014 frame solutions. Results will be presented in the poster.
Chris Maple, P A; Gunn, Annabel; Sellwood, Jane; Brown, David W G; Gray, Jim J
2009-02-01
The performance of fifteen, commercially available, VZV IgG assays and an "in house" indirect immunofluorescence (IF) assay has been compared to a reference VZV IgG time resolved immunofluorescence assay (VZV TRFIA). A panel of 273 VZV TRFIA IgG positive serum samples and 136 VZV TRFIA IgG susceptible sera, collected from a number of UK hospitals was used. Irrespective of the interpretation of equivocal results the most sensitive assays were Dade Behring EIA (97.4%), "in house" IF (95.2%), Human EIA (92.3%) and Becton Dickinson latex agglutination (94.1%). The least sensitive assays were Virion EIA (69.6%), Diesse EIA (68.9%) and Diasys EIA (68.5%). The least sensitive (<70%) assays all had >99.0% specificity whereas the most sensitive assays had lower specificities; for example, Dade Behring EIA had a specificity of 69.9% when equivocals were treated as VZV IgG negative. For some assays e.g. Dade Behring EIA there were major discrepancies between our findings and those reported by the manufacturer which may reflect the constitution of the panel(s) of sera used for evaluation or the reference method adopted or the choice of cut-off criteria (particularly relevant to our findings for the Behring EIA). Care must be taken to choose an assay with high specificity in order to accurately assess the need for vaccination or immunoprophylaxis; however, high sensitivity is preferable to prevent inappropriate and expensive treatment.
Multilayer Model: A New Regional Ionospheric Model For Near Real-Time Applications
NASA Astrophysics Data System (ADS)
Magnet, N.; Weber, R.
2012-12-01
The ionosphere is part of the upper atmosphere which affects electromagnetic waves by its ionization. The resulting propagation delay is frequency dependent, so it can be determined with dual frequency measurements. In case of single frequency users ionospheric models are used to correct the measurements. At the Institute of Geodesy and Geophysics (Vienna University of Technology) a new ionospheric model, labeled Multilayer Model, is under development. It consists of nine horizontal equidistant electron layers within the height range of the F2 layer, where the maximum of the ionization can be found. The remaining ionospheric layers (e.g. the E-layers) are currently not considered. The electron content of each of the nine layers is obtained from a simple model with very few parameters, like the current maximum VTEC and weighting functions to account for the spherical distance between the coordinates of the electron maximum and the IPP-points of interest. All parameters are calculated with hourly time resolution from a combination of global (IGS-stations) and regional GNSS observation data. The Multilayer Model focuses on regional densification of global ionosphere models (e.g. IGS VTEC SH models) by means of a small and easy predictable set of parameters. The final ionospheric TEC grids provided by IGS (International GNSS Service) have a resolution of 2 hours x 5° Longitude x 2.5° Latitude. Daily files can be downloaded from the IGS web page (http://www.igs.org/). IRI (International Reference Ionosphere) is a joint project of the Committee on Space Research (COSPAR) and the International Union of Radio Science (URSI). An empirical standard model of the ionosphere is provided which is based on a worldwide network of ionosondes, incoherent scatter radars and other data sources. In this presentation the VTEC values calculated with the regional Multilayer Model are compared to the results of the IGS global TEC grids and IRI. This comparison covers days with low ionospheric activity as well as days with high ionospheric disturbances over the region of Austria in order to evaluate the new model. In addition the produced IONEX-files of the Multilayer Model are used to evaluate the positioning accuracy achieved by processing tracking data of a regional single-frequency GNSS network.
Analysis of Vlbi, Slr and GPS Site Position Time Series
NASA Astrophysics Data System (ADS)
Angermann, D.; Krügel, M.; Meisel, B.; Müller, H.; Tesmer, V.
Conventionally the IERS terrestrial reference frame (ITRF) is realized by the adoption of a set of epoch coordinates and linear velocities for a set of global tracking stations. Due to the remarkable progress of the space geodetic observation techniques (e.g. VLBI, SLR, GPS) the accuracy and consistency of the ITRF increased continuously. The accuracy achieved today is mainly limited by technique-related systematic errors, which are often poorly characterized or quantified. Therefore it is essential to analyze the individual techniques' solutions with respect to systematic differences, models, parameters, datum definition, etc. Main subject of this presentation is the analysis of GPS, SLR and VLBI time series of site positions. The investigations are based on SLR and VLBI solutions computed at DGFI with the software systems DOGS (SLR) and OCCAM (VLBI). The GPS time series are based on weekly IGS station coordinates solutions. We analyze the time series with respect to the issues mentioned above. In particular we characterize the noise in the time series, identify periodic signals, and investigate non-linear effects that complicate the assignment of linear velocities for global tracking sites. One important aspect is the comparison of results obtained by different techniques at colocation sites.
Ota, Tatsuya; Rast, Jonathan P.; Litman, Gary W.; Amemiya, Chris T.
2003-01-01
The lineage leading to lungfishes is one of the few major jawed vertebrate groups in which Ig heavy chain isotype structure has not been investigated at the genetic level. In this study, we have characterized three different Ig heavy chain isotypes of the African lungfish, Protopterus aethiopicus, including an IgM-type heavy chain and short and long forms of non-IgM heavy chains. Northern blot analysis as well as patterns of VH utilization suggest that the IgM and non-IgM isotypes are likely encoded in separate loci. The two non-IgM isotypes identified in Protopterus share structural features with the short and long forms of IgX/W/NARC (referred to hereafter as IgW), which were previously considered to be restricted to the cartilaginous fish. It seems that the IgW isotype has a far broader phylogenetic distribution than considered originally and raises questions with regard to the origin and evolutionary divergence of IgM and IgW. Moreover, its absence in other gnathostome lineages implies paradoxically that the IgW-type genes were lost from teleost and tetrapod lineages. PMID:12606718
Lederer, Sabine; Lattwein, Erik; Hanke, Merle; Sonnenberg, Karen; Stoecker, Winfried; Lundkvist, Åke; Vaheri, Antti; Vapalahti, Olli; Chan, Paul K. S.; Feldmann, Heinz; Dick, Daryl; Schmidt-Chanasit, Jonas; Padula, Paula; Vial, Pablo A.; Panculescu-Gatej, Raluca; Ceianu, Cornelia; Heyman, Paul; Avšič-Županc, Tatjana; Niedrig, Matthias
2013-01-01
In order to detect serum antibodies against clinically important Old and New World hantaviruses simultaneously, multiparametric indirect immunofluorescence assays (IFAs) based on biochip mosaics were developed. Each of the mosaic substrates consisted of cells infected with one of the virus types Hantaan (HTNV), Puumala (PUUV), Seoul (SEOV), Saaremaa (SAAV), Dobrava (DOBV), Sin Nombre (SNV) or Andes (ANDV). For assay evaluation, serum IgG and IgM antibodies were analyzed using 184 laboratory-confirmed hantavirus-positive sera collected at six diagnostic centers from patients actively or previously infected with the following hantavirus serotypes: PUUV (Finland, n = 97); SEOV (China, n = 5); DOBV (Romania, n = 7); SNV (Canada, n = 23); ANDV (Argentina and Chile, n = 52). The control panel comprised 89 sera from healthy blood donors. According to the reference tests, all 184 patient samples were seropositive for hantavirus-specific IgG (n = 177; 96%) and/or IgM (n = 131; 72%), while all control samples were tested negative. In the multiparametric IFA applied in this study, 183 (99%) of the patient sera were IgG and 131 (71%) IgM positive (accordance with the reference tests: IgG, 96%; IgM, 93%). Overall IFA sensitivity for combined IgG and IgM analysis amounted to 100% for all serotypes, except for SNV (96%). Of the 89 control sera, 2 (2%) showed IgG reactivity against the HTNV substrate, but not against any other hantavirus. Due to the high cross-reactivity of hantaviral nucleocapsid proteins, endpoint titrations were conducted, allowing serotype determination in >90% of PUUV- and ANDV-infected patients. Thus, multiparametric IFA enables highly sensitive and specific serological diagnosis of hantavirus infections and can be used to differentiate PUUV and ANDV infection from infections with Murinae-borne hantaviruses (e.g. DOBV and SEOV). PMID:23593524
Blacksell, Stuart D.; Tanganuchitcharnchai, Ampai; Jintaworn, Suthatip; Kantipong, Pacharee; Richards, Allen L.; Day, Nicholas P. J.
2016-01-01
The enzyme-linked immunosorbent assay (ELISA) has been proposed as an alternative serologic diagnostic test to the indirect immunofluorescence assay (IFA) for scrub typhus. Here, we systematically determine the optimal sample dilution and cutoff optical density (OD) and estimate the accuracy of IgM ELISA using Bayesian latent class models (LCMs). Data from 135 patients with undifferentiated fever were reevaluated using Bayesian LCMs. Every patient was evaluated for the presence of an eschar and tested with a blood culture for Orientia tsutsugamushi, three different PCR assays, and an IgM IFA. The IgM ELISA was performed for every sample at sample dilutions from 1:100 to 1:102,400 using crude whole-cell antigens of the Karp, Kato, and Gilliam strains of O. tsutsugamushi developed by the Naval Medical Research Center. We used Bayesian LCMs to generate unbiased receiver operating characteristic curves and found that the sample dilution of 1:400 was optimal for the IgM ELISA. With the optimal cutoff OD of 1.474 at a sample dilution of 1:400, the IgM ELISA had a sensitivity of 85.7% (95% credible interval [CrI], 77.4% to 86.7%) and a specificity of 98.1% (95% CrI, 97.2% to 100%) using paired samples. For the ELISA, the OD could be determined objectively and quickly, in contrast to the reading of IFA slides, which was both subjective and labor-intensive. The IgM ELISA for scrub typhus has high diagnostic accuracy and is less subjective than the IgM IFA. We suggest that the IgM ELISA may be used as an alternative reference test to the IgM IFA for the serological diagnosis of scrub typhus. PMID:27008880
Antibodies to molds and satratoxin in individuals exposed in water-damaged buildings.
Vojdani, Aristo; Thrasher, Jack D; Madison, Roberta A; Gray, Michael R; Heuser, Gunnar; Campbell, Andrew W
2003-07-01
Immunoglobulin (Ig)A, IgM, and IgG antibodies against Penicillium notatum, Aspergillus niger, Stachybotrys chartarum, and satratoxin H were determined in the blood of 500 healthy blood donor controls, 500 random patients, and 500 patients with known exposure to molds. The patients were referred to the immunological testing laboratory for health reasons other than mold exposure, or for measurement of mold antibody levels. Levels of IgA, IgM, and IgG antibodies against molds were significantly greater in the patients (p < 0.001 for all measurements) than in the controls. However, in mold-exposed patients, levels of these antibodies against satratoxin differed significantly for IgG only (p < 0.001), but not for IgM or IgA. These differences in the levels of mold antibodies among the 3 groups were confirmed by calculation of z score and by Scheffé's significant difference tests. A general linear model was applied in the majority of cases, and 3 different subsets were formed, meaning that the healthy control groups were different from the random patients and from the mold-exposed patients. These findings indicated that mold exposure was more common in patients who were referred for immunological evaluation than it was in healthy blood donors. The detection of antibodies to molds and satratoxin H likely resulted from antigenic stimulation of the immune system and the reaction of serum with specially prepared mold antigens. These antigens, which had high protein content, were developed in this laboratory and used in the enzyme-linked immunosorbent assay (ELISA) procedure. The authors concluded that the antibodies studied are specific to mold antigens and mycotoxins, and therefore could be useful in epidemiological and other studies of humans exposed to molds and mycotoxins.
Huin-Schohn, Cécile; Guéguinou, Nathan; Schenten, Véronique; Bascove, Matthieu; Koch, Guillemette Gauquelin; Baatout, Sarah; Tschirhart, Eric; Frippiat, Jean-Pol
2013-01-01
Our previous research demonstrated that spaceflight conditions affect antibody production in response to an antigenic stimulation in adult amphibians. Here, we investigated whether antibody synthesis is affected when animal development occurs onboard a space station. To answer this question, embryos of the Iberian ribbed newt, Pleurodeles waltl, were sent to the International Space Station (ISS) before the initiation of immunoglobulin heavy-chain expression. Thus, antibody synthesis began in space. On landing, we determined the effects of spaceflight on P. waltl development and IgM heavy-chain transcription. Results were compared with those obtained using embryos that developed on Earth. We find that IgM heavy-chain transcription is doubled at landing and that spaceflight does not affect P. waltl development and does not induce inflammation. We also recreated the environmental modifications encountered by the embryos during their development onboard the ISS. This strategy allowed us to demonstrate that gravity change is the factor responsible for antibody heavy-chain transcription modifications that are associated with NF-κB mRNA level variations. Taken together, and given that the larvae were not immunized, these data suggest a modification of lymphopoiesis when gravity changes occur during ontogeny.
NASA Astrophysics Data System (ADS)
Wielgosz, P. A.
In this year, the system of active geodetic GPS permanent stations is going to be estab- lished in Poland. This system should provide GPS observations for a wide spectrum of users, especially it will be a great opportunity for surveyors. Many of surveyors still use cheaper, single frequency receivers. This paper focuses on processing of single frequency GPS observations only. During processing of such observations the iono- sphere plays an important role, so we concentrated on the influence of the ionosphere on the positional coordinates. Twenty consecutive days of GPS data from 2001 year were processed to analyze the accuracy of a derived three-dimensional relative vec- tor position between GPS stations. Observations from two Polish EPN/IGS stations: BOGO and JOZE were used. In addition to, a new test station - IGIK was created. In this paper, the results of single frequency GPS observations processing in near real- time are presented. Baselines of 15, 27 and 42 kilometers and sessions of 1, 2, 3, 4, and 6 hours long were processed. While processing we used CODE (Centre for Orbit De- termination in Europe, Bern, Switzerland) predicted products: orbits and ionosphere info. These products are available in real-time and enable near real-time processing. Software Bernese v. 4.2 for Linux and BPE (Bernese Processing Engine) mode were used. These results are shown with a reference to dual frequency weekly solution (the best solution). Obtained GPS positional time and GPS baseline length dependency accuracy is presented for single frequency GPS observations.
GPS IPW as a Meteorological Parameter and Climate Global Change Indicator
NASA Astrophysics Data System (ADS)
Kruczyk, M.; Liwosz, T.
2011-12-01
Paper focuses on comprehensive investigation of the GPS derived IPW (Integrated Precipitable Water, also IWV) as a geophysical tool. GPS meteorology is now widely acknowledged indirect method of atmosphere sensing. First we demonstrate GPS IPW quality. Most thorough inter-technique comparisons of directly measured IPW are attainable only for some observatories (note modest percentage of GPS stations equipped with meteorological devices). Nonetheless we have managed to compare IPW series derived from GPS tropospheric solutions (ZTD mostly from IGS and EPN solutions) and some independent techniques. IPW values from meteorological sources we used are: radiosoundings, sun photometer and input fields of numerical weather prediction model. We can treat operational NWP models as meteorological database within which we can calculate IWV for all GPS stations independently from network of direct measurements (COSMO-LM model maintained by Polish Institute of Meteorology and Water Management was tried). Sunphotometer (CIMEL-318, Central Geophysical Observatory IGF PAS, Belsk, Poland) data seems the most genuine source - so we decided for direct collocation of GPS measurements and sunphotometer placing permanent GPS receiver on the roof of Belsk Observatory. Next we analyse IPW as geophysical parameter: IPW demonstrates some physical effects evoked by station location (height and series correlation coefficient as a function of distance) and weather patterns like dominant wind directions (in case of neighbouring stations). Deficiency of surface humidity data to model IPW is presented for different climates. This inadequacy and poor humidity data representation in NWP model extremely encourages investigating information exchange potential between Numerical Model and GPS network. The second and most important aspect of this study concerns long series of IPW (daily averaged) which can serve as climatological information indicator (water vapour role in climate system is hard to exaggerate). Especially intriguing are relatively unique shape of such series in different climates. Long lasting changes in weather conditions: 'dry' and 'wet' years are also visible. The longer and more uniform our series are the better chance to estimate the magnitude of climatological IWV changes. Homogenous ZTD solution during long period is great concern in this approach (problems with GPS strategy and reference system changes). In case of continental network (EUREF Permanent Network) reliable data we get only after reprocessing. Simple sinusoidal model has been adjusted to the IPW series (LS method) for selected stations (mainly Europe but also other continents - IGS stations), every year separately. Not only amplitudes but also phases of annual signal differ from year to year. Longer IPW series (up to 14 years) searched for some climatological signal sometimes reveal weak steady trend. Large number of GPS permanent stations, relative easiness of IPW derivation (only and surface meteo data needed apart from GPS solution) and water vapour significance in water cycle and global climate make this GPS IPW promising element of global environmental change monitoring.
Serum concentrations of IgG, IgA, and IgM in retired racing Greyhound dogs.
Clemente, Mónica; Marín, Liliana; Iazbik, M Cristina; Couto, C Guillermo
2010-12-01
Greyhound dogs have significant physiologic, hematologic, and biochemical differences when compared with other breeds, including significantly lower serum globulin concentration owing to decreases in the α- and β-globulin fractions. The specific proteins that account for differences in globulin concentrations are not known, but IgA and IgM, both β-globulins, are potential candidates. The aims of this study were to measure serum IgG, IgA, and IgM in clinically healthy retired racing Greyhounds and compare the results with those of age- and sex-matched non-Greyhound dogs. Study animals included 25 Greyhound and 20 non-Greyhound dogs. Total protein, albumin, and total globulin concentrations were determined. IgG, IgA, and IgM concentrations were measured using a commercially available radial immunodiffusion kit. The Student t-test assuming equal variances was used to compare concentrations of immunoglobulins between groups. Serum concentrations of IgA and IgM in Greyhounds (IgA=49±20 mg/dL; IgM=132±47 mg/dL) were significantly lower than concentrations in non-Greyound dogs (IgA=70±39 mg/dL; Ig M=212±78 mg/dL). Concentrations of IgG did not differ between groups. Mean serum IgA and IgM concentrations in Greyhounds were lower than those in non-Greyhound dogs. This may contribute to low serum concentrations of β-globulins in Greyhounds. Specific reference intervals are recommended for Greyhounds to avoid possible misdiagnosis of IgA or IgM deficiency. ©2010 American Society for Veterinary Clinical Pathology.
Studies on spatio-temporal filtering of GNSS-derived coordinates
NASA Astrophysics Data System (ADS)
Gruszczynski, Maciej; Bogusz, Janusz; Kłos, Anna; Figurski, Mariusz
2015-04-01
The information about lithospheric deformations may be obtained nowadays by analysis of velocity field derived from permanent GNSS (Global Navigation Satellite System) observations. Despite developing more and more reliable models, the permanent stations residuals must still be considered as coloured noise. Meeting the GGOS (Global Geodetic Observing System) requirements, we are obliged to investigate the correlations between residuals, which are the result of common mode error (CME). This type of error may arise from mismodelling of: satellite orbits, the Earth Orientation Parameters, satellite antenna phase centre variations or unmodelling of large scale atmospheric effects. The above described together cause correlations between stochastic parts of coordinate time series obtained at stations located of even few thousands kilometres from each other. Permanent stations that meet the aforementioned terms form the regional (EPN - EUREF Permanent Network) or local sub-networks of global (IGS - International GNSS Service) network. Other authors (Wdowinski et al., 1997; Dong et al., 2006) dealt with spatio-temporal filtering and indicated three major regional filtering approaches: the stacking, the Principal Component Analysis (PCA) based on the empirical orthogonal function and the Karhunen-Loeve expansion. The need for spatio-temporal filtering is evident today, but the question whether the size of the network affects the accuracy of station's position and its velocity still remains unanswered. With the aim to determine the network's size, for which the assumption of spatial uniform distribution of CME is retained, we used stacking approach. We analyzed time series of IGS stations with daily network solutions processed by the Military University of Technology EPN Local Analysis Centre in Bernese 5.0 software and compared it with the JPL (Jet Propulsion Laboratory) PPP (Precice Point Positioning). The method we propose is based on the division of local GNSS networks into concentric ring-shaped areas. Such an approach allows us to specify the maximum size of the network, where the evident uniform spatial response can be still noticed. In terms of reliable CMEs extraction, the local networks have to be up to 500-600 kilometres extent depending on its character (location). In this study we examined three approaches of spatio-temporal filtering based on stacking procedure. First was based on non-weighted (Wdowinski et. al., 1997) and second on weighted average formula, where the weights are formed by the RMS of individual station position in the corresponding epoch (Nikolaidis, 2002). The third stacking approach, proposed here, was previously unused. It combines the weighted stacking together with the distance between the station and network barycentre into one approach. The analysis allowed to determine the optimal size of local GNSS network and to select the appropriate stacking method for obtaining the most stable solutions for e.g. geodynamical studies. The values of L1 and L2 norms, RMS values of time series (describing stability of the time series) and Pearson correlation coefficients were calculated for the North, East and Up components from more than 200 permanent stations twice: before performing the filtration and after weighted stacking approach. We showed the improvement in the quality of time series analysis using MLE (Maximum Likelihood Estimation) to estimate noise parameters. We demonstrated that the relative RMS improvement of 10, 20 and 30% reduces the noise amplitudes of about 20, 35 and 45%, respectively, what causes the velocity uncertainty to be reduced of 0.3 mm/yr (for the assumption of 7-years of data and flicker noise). The relative decrement of spectral index kappa is 25, 35 and 45%, what means lower velocity uncertainty of even 0.2 mm/yr (when assuming 7 years of data and noise amplitude of 15 mm/yr^-kappa/4) . These results refer to the growing demands on the stability of the series due to their use to realize the kinematic reference frames and for geodynamical studies.
GNSS Network Time Series Analysis
NASA Astrophysics Data System (ADS)
Balodis, J.; Janpaule, I.; Haritonova, D.; Normand, M.; Silabriedis, G.; Zarinjsh, A.; Zvirgzds, J.
2012-04-01
Time series of GNSS station results of both the EUPOS®-RIGA and LATPOS networks has been developed at the Institute of Geodesy and Geoinformation (University of Latvia) using Bernese v.5.0 software. The base stations were selected among the EPN and IGS stations in surroundings of Latvia. In various day solutions the base station selection has been miscellaneous. Most frequently 5 - 8 base stations were selected from a set of stations {BOR1, JOEN, JOZE, MDVJ, METS, POLV, PULK, RIGA, TORA, VAAS, VISO, VLNS}. The rejection of "bad base stations" was performed by Bernese software depending on the quality of proper station data in proper day. This caused a reason of miscellaneous base station selection in various days. The results of time series are analysed. The question aroused on the nature of some outlying situations. The seasonal effect of the behaviour of the network has been identified when distance and elevation changes between stations has been analysed. The dependence from various influences has been recognised.
Mendez Astudillo, Jorge; Lau, Lawrence; Tang, Yu-Ting; Moore, Terry
2018-02-14
As Global Navigation Satellite System (GNSS) signals travel through the troposphere, a tropospheric delay occurs due to a change in the refractive index of the medium. The Precise Point Positioning (PPP) technique can achieve centimeter/millimeter positioning accuracy with only one GNSS receiver. The Zenith Tropospheric Delay (ZTD) is estimated alongside with the position unknowns in PPP. Estimated ZTD can be very useful for meteorological applications, an example is the estimation of water vapor content in the atmosphere from the estimated ZTD. PPP is implemented with different algorithms and models in online services and software packages. In this study, a performance assessment with analysis of ZTD estimates from three PPP online services and three software packages is presented. The main contribution of this paper is to show the accuracy of ZTD estimation achievable in PPP. The analysis also provides the GNSS users and researchers the insight of the processing algorithm dependence and impact on PPP ZTD estimation. Observation data of eight whole days from a total of nine International GNSS Service (IGS) tracking stations spread in the northern hemisphere, the equatorial region and the southern hemisphere is used in this analysis. The PPP ZTD estimates are compared with the ZTD obtained from the IGS tropospheric product of the same days. The estimates of two of the three online PPP services show good agreement (<1 cm) with the IGS ZTD values at the northern and southern hemisphere stations. The results also show that the online PPP services perform better than the selected PPP software packages at all stations.
van Hoeven, Karen H.; Dale, Connie; Foster, Phil; Body, Barbara
2008-01-01
Accurate determination of the concentrations of immunoglobulin G (IgG) antibody to tetanus toxoid is important in order to evaluate the immunogenicity of tetanus toxoid vaccines, determine immune competence in individual patients, and measure the prevalence of immunity in populations. The performance of three commercially available enzyme-linked immunosorbent assays (ELISAs) for IgG antibodies to tetanus toxoid were evaluated. Serially diluted NIBSC 76/589 and TE-3 human tetanus IgG immunoglobulin international reference standards were analyzed in quadruplicate using ELISAs manufactured by The Binding Site, Inc. (VaccZyme); Scimedx; and Euroimmun. In addition, IgG antibodies to tetanus toxoid were measured in 83 deidentified serum specimens using each manufacturer's ELISA. Each ELISA provided linear results when evaluated with the reference preparations. The Binding Site ELISA provided results that closely corresponded to the reference preparations (y = 1.09x − 0.08), whereas the Scimedx ELISA gave results that were consistently lower (y = 0.21x − 0.07) and the Euroimmun ELISA gave results that were consistently higher (y = 1.5x + 0.30) than the reference preparation concentrations. Using the recommended cutoff for each ELISA (<0.10 IU/ml), the overall agreement of all of the ELISA methods was 78%. Three of eighty-three (3.6%) human serum samples demonstrated inadequate immunity with all three assays. The Binding Site ELISA yielded nonprotective antibody concentrations in only these 3 samples, whereas 19 samples (22.9%) according to the Scimedx ELISA and 6 samples (7.2%) according to the Euroimmun ELISA demonstrated nonprotective concentrations. The performance characteristics of ELISAs for tetanus immunoglobulin titers were manufacturer dependent, and the differences translated into important disparities in reported results. PMID:18845832
GNSS Network time series analysis
NASA Astrophysics Data System (ADS)
Normand, M.; Balodis, J.; Janpaule, I.; Haritonova, D.
2012-12-01
Time series of GNSS station results of both the EUPOS®-Riga and LatPos networks have been developed at the Institute of Geodesy and Geoinformation (University of Latvia) using Bernese v.5.0 software. The base stations were selected among the EPN and IGS stations in surroundings of Latvia at the distances up to 700 km. The results of time series are analysed and coordinate velocity vectors have been determined. The background of the map of tectonic faults helps to interpret the GNSS station coordinate velocity vector behaviour in proper environment. The outlying situations recognized. The question still aroused on the nature of the some of outlying situations. The dependence from various influences has been tested.
Ackermann-Gäumann, Rahel; Tritten, Marie-Lise; Hassan, Mona; Lienhard, Reto
2018-05-01
Tick-borne encephalitis (TBE) is endemic in many parts of Europe and Asia. The diagnosis of this disease is essentially based on the demonstration of specific antibodies. For reasons of simplicity, automatization and quick availability of test results, enzyme-linked immunosorbent assays (ELISAs) are the method of choice for serological diagnosis of TBE. Here, we evaluated three commercially available anti-TBEV IgG and IgM ELISAs using 251 serum samples: the SERION ELISA classic FSME Virus/TBE Virus IgG and IgM kit (Virion\\Serion), the RIDASCREEN ® FSME/TBE IgG and IgM kit (R-Biopharm), and the anti-FSME/TBE virus ELISA "Vienna" IgG/anti-FSME/TBE virus ELISA IgM kit (Euroimmun). In total, discrepant test results for IgG and/or IgM were observed for 37/251 (14.7 %) of tested samples; differences were statistically significant. Reference values defined by serum neutralization test (SNT, n = 25) or results provided by EQA organizers (n = 2) were established for a subset of samples. In relation to these values, false-positive results were observed mainly for Euroimmun Vienna IgG and RIDASCREEN IgG, whereas false-negative results were primarily observed for Virion\\Serion IgG and RIDASCREEN IgM kits. In routine diagnostics, specificity problems are of major relevance and may be addressed by analyzing the respective samples using SNT. Copyright © 2018 Elsevier GmbH. All rights reserved.
Dahle, C; Hagman, A; Ignatova, S; Ström, M
2010-07-01
This study was done to evaluate the diagnostic utility of antibodies against deamidated gliadin peptides compared to traditional markers for coeliac disease. To evaluate diagnostic utility of antibodies against deamidated gliadin peptide (DGP). Sera from 176 adults, referred for endoscopy without previous analysis of antibodies against tissue transglutaminase (tTG) or endomysium (EmA), were retrospectively analysed by ELISAs detecting IgA/IgG antibodies against DGP or a mixture of DGP and tTG, and compared with IgA-tTG and EmA. Seventy-nine individuals were diagnosed with coeliac disease. Receiver operating characteristic analyses verified the manufacturers' cut-off limits except for IgA/IgG-DGP/tTG. In sera without IgA deficiency, the sensitivity was higher for IgA/IgG-DGP (0.85-0.87) compared with IgA-tTg (0.76) and EmA (0.61). All tests showed high specificity (0.95-1.00). Eighteen coeliac disease-sera were negative regarding IgA-tTG, nine of which were positive for IgA/IgG-DGP. Sera from coeliac disease-patients >70 years were more often negative for IgA-tTG (50%) and IgA/IgG-DGP (36%) than younger patients (15% and 8% respectively) (P < 0.01). Three of the four IgA-deficient patients were positive in the IgA/IgG-DGP assay. In this study of patients unselected regarding IgA-tTg/EmA, thus unbiased in this respect, IgA/IgG-DGP identified adult coeliac disease patients negative for antibodies against endomysium and tissue transglutaminase. Serology is often negative in elderly patients with coeliac disease; a small bowel biopsy should therefore be performed generously before coeliac disease is excluded.
NASA Astrophysics Data System (ADS)
Ghaffari Razin, Mir Reza; Voosoghi, Behzad
2017-04-01
Ionospheric tomography is a very cost-effective method which is used frequently to modeling of electron density distributions. In this paper, residual minimization training neural network (RMTNN) is used in voxel based ionospheric tomography. Due to the use of wavelet neural network (WNN) with back-propagation (BP) algorithm in RMTNN method, the new method is named modified RMTNN (MRMTNN). To train the WNN with BP algorithm, two cost functions is defined: total and vertical cost functions. Using minimization of cost functions, temporal and spatial ionospheric variations is studied. The GPS measurements of the international GNSS service (IGS) in the central Europe have been used for constructing a 3-D image of the electron density. Three days (2009.04.15, 2011.07.20 and 2013.06.01) with different solar activity index is used for the processing. To validate and better assess reliability of the proposed method, 4 ionosonde and 3 testing stations have been used. Also the results of MRMTNN has been compared to that of the RMTNN method, international reference ionosphere model 2012 (IRI-2012) and spherical cap harmonic (SCH) method as a local ionospheric model. The comparison of MRMTNN results with RMTNN, IRI-2012 and SCH models shows that the root mean square error (RMSE) and standard deviation of the proposed approach are superior to those of the traditional method.
Effects of spaceflight on the immunoglobulin repertoire of unimmunized C57BL/6 mice
NASA Astrophysics Data System (ADS)
Ward, Claire; Rettig, Trisha A.; Hlavacek, Savannah; Bye, Bailey A.; Pecaut, Michael J.; Chapes, Stephen K.
2018-02-01
Spaceflight has been shown to suppress the adaptive immune response, altering the distribution and function of lymphocyte populations. B lymphocytes express highly specific and highly diversified receptors, known as immunoglobulins (Ig), that directly bind and neutralize pathogens. Ig diversity is achieved through the enzymatic splicing of gene segments within the genomic DNA of each B cell in a host. The collection of Ig specificities within a host, or Ig repertoire, has been increasingly characterized in both basic research and clinical settings using high-throughput sequencing technology (HTS). We utilized HTS to test the hypothesis that spaceflight affects the B-cell repertoire. To test this hypothesis, we characterized the impact of spaceflight on the unimmunized Ig repertoire of C57BL/6 mice that were flown aboard the International Space Station (ISS) during the Rodent Research One validation flight in comparison to ground controls. Individual gene segment usage was similar between ground control and flight animals, however, gene segment combinations and the junctions in which gene segments combine was varied among animals within and between treatment groups. We also found that spontaneous somatic mutations in the IgH and Igκ gene loci were not increased. These data suggest that space flight did not affect the B cell repertoire of mice flown and housed on the ISS over a short period of time.
Marriage, D E; Erlewyn-Lajeunesse, M; Unsworth, D J; Henderson, A J
2012-01-01
Resolution of egg allergy occurs in the majority of egg allergic children. Positive specific IgE antibodies to ovomucoid (OVM) have been suggested to be of greater predictive value for persistent egg allergy than specific IgE to egg white. The performance of OVM-specific IgE antibody levels in a cohort of children referred for a routine egg challenge was compared with egg white specific IgE levels in predicting a positive egg challenge. 24/47 subjects had persistent egg allergy. Receiver operating characteristic analysis showed that OVM-specific IgE testing was the most useful test for the diagnosis of persistent egg allergy. The optimal decision points for the prediction of persistent egg allergy were >0.35 kUA/L for specific IgE levels to both EW and OVM, and ≥3 mm for SPT. Children with specific IgE levels suggestive of persistent egg allergy need not be subject to an egg provocation challenge, reducing both costs and risks to the child.
Cocoa-enriched diets modulate intestinal and systemic humoral immune response in young adult rats.
Pérez-Berezo, Teresa; Franch, Angels; Ramos-Romero, Sara; Castellote, Cristina; Pérez-Cano, Francisco J; Castell, Margarida
2011-05-01
Previous studies have shown that a highly enriched cocoa diet affects both intestinal and systemic immune function in young rats. The aim of this study was to elucidate whether diets containing lower amounts of cocoa could also influence the systemic and intestinal humoral immune response. Fecal and serum samples were collected during the study and, at the end, intestinal washes were obtained and mesenteric lymph nodes and small-intestine walls were excised for gene expression assessment. IgA, IgM, IgG1, IgG2a, IgG2b and IgG2c concentrations were quantified in serum whereas S-IgA and S-IgM were determined in feces and intestinal washes. Animals receiving 5 and 10% cocoa for 3 wk showed no age-related increase in serum IgG1 and IgG2a concentrations, and IgG2a values were significantly lower than those in reference animals. Serum IgM was also decreased by the 10% cocoa diet. The 5 and 10% cocoa diets dramatically reduced intestinal S-IgA concentration and modified the expression of several genes involved in IgA synthesis. A diet containing 2% cocoa had no effect on most of the studied variables. The results demonstrate the downregulatory effect of a 5% or higher cocoa diet on the systemic and intestinal humoral immune response in adult rats. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Performance Evaluation of Real-Time Precise Point Positioning Method
NASA Astrophysics Data System (ADS)
Alcay, Salih; Turgut, Muzeyyen
2017-12-01
Post-Processed Precise Point Positioning (PPP) is a well-known zero-difference positioning method which provides accurate and precise results. After the experimental tests, IGS Real Time Service (RTS) officially provided real time orbit and clock products for the GNSS community that allows real-time (RT) PPP applications. Different software packages can be used for RT-PPP. In this study, in order to evaluate the performance of RT-PPP, 3 IGS stations are used. Results, obtained by using BKG Ntrip Client (BNC) Software v2.12, are examined in terms of both accuracy and precision.
Anitharaj, Velmurugan; Stephen, Selvaraj; Pradeep, Jothimani; Park, Sungman; Kim, Seung-Han; Kim, Young Jin; Kim, Eun-Ye; Kim, Yoon-Won
2016-11-01
Scrub Typhus (ST) is being reported from different parts of India in the recent past. However, the diagnosis and confirmation of ST cases require specific serological and molecular diagnostic tests. Both rapid and conventional ELISA tests need to be properly evaluated. Evaluation of a new ST IgM Immunochromatography (ICT) test kit (InBios Scrub Typhus Detect IgM Rapid Test) and compare it with another rapid kit, conventional ELISA kit and Weil-Felix (WF) test. This prospective study was carried out in Mahatma Gandhi Medical College and Research Institute, Puducherry, during November 2015 to June 2016. Clinically suspected 220 ST patients were examined by a new kit, InBios Scrub Typhus Detect IgM Rapid Test, taking the conventional InBios Scrub Typhus Detect IgM ELISA as reference. Additional comparison was made with ImmuneMed Scrub Typhus Rapid, and WF test (single OXK titers ≥1:320). Statistical analysis was performed (Chi-square, Spearman's correlation and Kappa) using IBM SPSS Statistics 17 for Windows (SPSS Inc; Chicago, USA). Percentage Sensitivity, Specificity, Positive Predictive and Negative Predictive Values for InBios, ImmuneMed and WF were 99.25, 93.02, 95.68, 98.77; 94.87, 94.19, 96.21, 92.05 and 50.38, 95.51, 94.29, 56.67 respectively. A total of 134 patients were positive in reference standard InBios IgM ELISA. This new rapid ST IgM kit validated for the first time in India, showed good sensitivity and specificity. As a Point-of-Care (PoC) test, the kit would be helpful in both urban and remote rural parts of India.
Anitharaj, Velmurugan; Pradeep, Jothimani; Park, Sungman; Kim, Seung-Han; Kim, Young Jin; Kim, Eun-Ye; Kim, Yoon-Won
2016-01-01
Introduction Scrub Typhus (ST) is being reported from different parts of India in the recent past. However, the diagnosis and confirmation of ST cases require specific serological and molecular diagnostic tests. Both rapid and conventional ELISA tests need to be properly evaluated. Aim Evaluation of a new ST IgM Immunochromatography (ICT) test kit (InBios Scrub Typhus Detect IgM Rapid Test) and compare it with another rapid kit, conventional ELISA kit and Weil-Felix (WF) test. Materials and Methods This prospective study was carried out in Mahatma Gandhi Medical College and Research Institute, Puducherry, during November 2015 to June 2016. Clinically suspected 220 ST patients were examined by a new kit, InBios Scrub Typhus Detect IgM Rapid Test, taking the conventional InBios Scrub Typhus Detect IgM ELISA as reference. Additional comparison was made with ImmuneMed Scrub Typhus Rapid, and WF test (single OXK titers ≥1:320). Statistical analysis was performed (Chi-square, Spearman’s correlation and Kappa) using IBM SPSS Statistics 17 for Windows (SPSS Inc; Chicago, USA). Results Percentage Sensitivity, Specificity, Positive Predictive and Negative Predictive Values for InBios, ImmuneMed and WF were 99.25, 93.02, 95.68, 98.77; 94.87, 94.19, 96.21, 92.05 and 50.38, 95.51, 94.29, 56.67 respectively. A total of 134 patients were positive in reference standard InBios IgM ELISA. Conclusion This new rapid ST IgM kit validated for the first time in India, showed good sensitivity and specificity. As a Point-of-Care (PoC) test, the kit would be helpful in both urban and remote rural parts of India. PMID:28050364
Status of Core Products of the International GNSS Service
NASA Astrophysics Data System (ADS)
Choi, K. K.
2014-12-01
The International GNSS Service (IGS) has been providing high accuracy GNSS orbits, clocks and Earth Rotation Parameters (ERP) in three different time intervals. The quality of the IGS core products are regularly monitored since 2010, and the level of accuracies has not been changed noticeably. The Final and Rapid orbit's accuracies are known to be about ~2.5 cm and the near-real time (observed) Ultra-rapid orbit is about 3 cm. The real-time orbits obtained by propagating the Ultra-rapid orbits shows an accuracy of about 5 cm. The most significant error source of the real-time orbit is the sub-daily variation of the Earth orientation. Number of IGS08 core sites has been decreasing with the rate of ~0.13 stations per week due to equipment changes and natural disasters such as Earthquakes. This paper summarizes the quality state of the IGS core products for 2014, and the upcoming new official product IGV, Glonass Ultra-rapid orbit product which have been experimental for last 4 years. Eight IGS Analysis Centers (ACs) have completed their efforts to participate in the second reprocessing campaign (repro2). Based on their input, this paper summarizes the models and methodologies each AC have adopted for this campaign.
Total Electron Content Retrieved From L-Band Radiometers and Potential Improvements to the IGS Model
NASA Astrophysics Data System (ADS)
Soldo, Yan; Hong, Liang; El-Nimri, Salem; Le Vine, David M.
2018-04-01
In recent years, several L-band microwave instruments have been launched into Earth's orbit to measure soil moisture and ocean salinity (e.g., Soil Moisture and Ocean Salinity [SMOS], Aquarius, and Soil Moisture Active/Passive [SMAP]). As the microwave signal travels through the ionosphere, the polarization vector rotates (Faraday rotation) and it is possible to estimate the total electron content (TEC) along the path by measuring this change. A comparison is presented of the TEC retrieved from Aquarius and SMAP over the ocean with the values provided by the IGS (International Global Navigation Satellite System Service (GNSS)). The TEC retrieved from Aquarius and SMAP measurements show good agreement with each other and, on a global scale, are in agreement with the TEC provided by the IGS. However, there are cases in which the TEC from the two satellite sensors are in good agreement with each other but differ significantly from the IGS TEC. The comparison suggests that the L-band instruments are a reliable source of TEC over the ocean and could be a valuable supplementary source of TEC values that could be assimilated in the IGS models, especially over the ocean, where GNSS ground stations are sparse.
NASA Astrophysics Data System (ADS)
Tsibanos, V.; Wang, G.
2017-12-01
The Long Point Fault located in Houston Texas is a complex system of normal faults which causes significant damage to urban infrastructure on both private and public property. This case study focuses on the 20-km long fault using high accuracy continuously operating global positioning satellite (GPS) stations to delineate fault movement over five years (2012 - 2017). The Long Point Fault is the longest active fault in the greater Houston area that damages roads, buried pipes, concrete structures and buildings and creates a financial burden for the city of Houston and the residents who live in close vicinity to the fault trace. In order to monitor fault displacement along the surface 11 permanent and continuously operating GPS stations were installed 6 on the hanging wall and 5 on the footwall. This study is an overview of the GPS observations from 2013 to 2017. GPS positions were processed with both relative (double differencing) and absolute Precise Point Positioning (PPP) techniques. The PPP solutions that are referred to IGS08 reference frame were transformed to the Stable Houston Reference Frame (SHRF16). Our results show no considerable horizontal displacements across the fault, but do show uneven vertical displacement attributed to regional subsidence in the range of (5 - 10 mm/yr). This subsidence can be associated to compaction of silty clays in the Chicot and Evangeline aquifers whose water depths are approximately 50m and 80m below the land surface (bls). These levels are below the regional pre-consolidation head that is about 30 to 40m bls. Recent research indicates subsidence will continue to occur until the aquifer levels reach the pre-consolidation head. With further GPS observations both the Long Point Fault and regional land subsidence can be monitored providing important geological data to the Houston community.
Limberková, R; Smíšková, D; Havlíčková, M; Herrmannová, K; Lexová, P; Malý, M
2015-03-01
Serological diagnosis of epidemic mumps can be difficult in vaccinated persons, particularly due to the absence of specific IgM antibodies. The aim was to find whether adding the detection of IgA antibodies to the currently used routine serological diagnosis of mumps (detection of IgM and IgG antibodies in an acute serum sample) would make the serological diagnosis of mumps more effective in a population with a high vaccination coverage. At the same time, ELISA kits for the detection of early IgA and IgM antibodies against the mumps virus were compared and statistical analysis of the results was performed. Sixty-four acute sera from patients with laboratory confirmed diagnosis of mumps were included in the study. Clinical specimens were collected at the onset of clinical symptoms. To test the sera, the MASTAZYME ELISA Mumps IgA kit (MAST DIAGNOSTICA, Germany) with the MASTSORB sorbent (RF and IgG) and Enzygnost Anti-Parotitis-Virus/IgM kit (Siemens, Germany) were used. A panel of 121 acute sera with no epidemiological link to mumps virus served as specificity controls for the IgA assay. The epidemiological data were derived from the EPIDAT system. The level of agreement was assessed using the McNemara test and Cohen's coefficient kappa. The Stata 9.2 software (Stata Corp LP, College Station, USA) was used for statistical analysis. The detection of IgA and IgM antibodies against the mumps virus yielded concordant results in 50/64 acute sera, 32 positive and 18 negative, i.e. an agreement of 78.12 %. Of the remaining 14 samples, 13 were only IgA positive and one was only IgM positive. The controls showed non-specific IgA positivity in 5/121 samples which indicates a 96% specificity. The absence of specific IgM antibodies against mumps virus is relatively often seen in vaccinated indivi-duals; nevertheless, the test is routinely used in patients with suspected active infection. The test for IgA antibodies, which is not routinely performed, significantly increased the detection rate of the disease. Based on the results of the present study, it can be concluded that the combination of the anti-mumps IgM and IgA assays increased the effectiveness of the serological diagnosis at the onset of clinical symptoms from less than 52% to nearly 72%.
Effects of spaceflight on the immunoglobulin repertoire of unimmunized C57BL/6 mice.
Ward, Claire; Rettig, Trisha A; Hlavacek, Savannah; Bye, Bailey A; Pecaut, Michael J; Chapes, Stephen K
2018-02-01
Spaceflight has been shown to suppress the adaptive immune response, altering the distribution and function of lymphocyte populations. B lymphocytes express highly specific and highly diversified receptors, known as immunoglobulins (Ig), that directly bind and neutralize pathogens. Ig diversity is achieved through the enzymatic splicing of gene segments within the genomic DNA of each B cell in a host. The collection of Ig specificities within a host, or Ig repertoire, has been increasingly characterized in both basic research and clinical settings using high-throughput sequencing technology (HTS). We utilized HTS to test the hypothesis that spaceflight affects the B-cell repertoire. To test this hypothesis, we characterized the impact of spaceflight on the unimmunized Ig repertoire of C57BL/6 mice that were flown aboard the International Space Station (ISS) during the Rodent Research One validation flight in comparison to ground controls. Individual gene segment usage was similar between ground control and flight animals, however, gene segment combinations and the junctions in which gene segments combine was varied among animals within and between treatment groups. We also found that spontaneous somatic mutations in the IgH and Igκ gene loci were not increased. These data suggest that space flight did not affect the B cell repertoire of mice flown and housed on the ISS over a short period of time. Copyright © 2017 The Committee on Space Research (COSPAR). Published by Elsevier Ltd. All rights reserved.
Seigneur, A; Hou, S; Shaw, R A; McClure, Jt; Gelens, H; Riley, C B
2015-01-15
Deficiency in immunoglobulin G (IgG) is associated with an increased susceptibility to infections in humans and animals, and changes in IgG levels occur in many disease states. In companion animals, failure of transfer of passive immunity is uncommonly diagnosed but mortality rates in puppies are high and more than 30% of these deaths are secondary to septicemia. Currently, radial immunodiffusion (RID) and enzyme-linked immunosorbent assays are the most commonly used methods for quantitative measurement of IgG in dogs. In this study, a Fourier-transform infrared spectroscopy (FTIR) assay for canine serum IgG was developed and compared to the RID assay as the reference standard. Basic signalment data and health status of the dogs were also analyzed to determine if they correlated with serum IgG concentrations based on RID results. Serum samples were collected from 207 dogs during routine hematological evaluation, and IgG concentrations determined by RID. The FTIR assay was developed using partial least squares regression analysis and its performance evaluated using RID assay as the reference test. The concordance correlation coefficient was 0.91 for the calibration model data set and 0.85 for the prediction set. A Bland-Altman plot showed a mean difference of -89 mg/dL and no systematic bias. The modified mean coefficient of variation (CV) for RID was 6.67%, and for FTIR was 18.76%. The mean serum IgG concentration using RID was 1943 ± 880 mg/dL based on the 193 dogs with complete signalment and health data. When age class, gender, breed size and disease status were analyzed by multivariable ANOVA, dogs < 2 years of age (p = 0.0004) and those classified as diseased (p = 0.03) were found to have significantly lower IgG concentrations than older and healthy dogs, respectively. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Roman, D. R.; Smith, D. A.
2017-12-01
In 2022, the National Geodetic Survey will replace all three NAD 83 reference frames with four new terrestrial reference frames. Each frame will be named after a tectonic plate (North American, Pacific, Caribbean and Mariana) and each will be related to the IGS frame through three Euler Pole parameters (EPPs). This talk will focus on three main areas of error propagation when defining coordinates in these four frames. Those areas are (1) use of the small angle approximation to relate true rotation about an Euler Pole to small rotations about three Cartesian axes (2) The current state of the art in determining the Euler Poles of these four plates and (3) the combination of both IGS Cartesian coordinate uncertainties and EPP uncertainties into coordinate uncertainties in the four new frames. Discussion will also include recent efforts at improving the Euler Poles for these frames and expected dates when errors in the EPPs will cause an unacceptable level of uncertainty in the four new terrestrial reference frames.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunter, C.; Simpson, J.; Kovats, Z.
Sediments from Soda Creek were evaluated using the Sediment Quality Triad as part of investigations being conducted at the Monsanto Company plant in Soda Springs, Idaho. Information collected by an ecological assessment included metal concentrations (arsenic, cadmium, copper, molybdenum, nickel, selenium, silver, and vanadium), benthic fauna community structure, and sediment toxicity. The collected sediments were composed of sandy-silt sized particles, with 2.4% to 9.1% organic carbon. Metal concentrations at sample stations were elevated relative to sediments collected from reference stations. For example, average cadmium concentrations ranged from 13 to 48 mg/kg at sample stations and 0.72 to 3.2 mg/kg atmore » reference stations; selenium concentrations ranged from 4.7 to 91 mg/kg at sample stations and 0.82 to 2.7 mg/kg at reference stations. Soda Creek has a relatively low flow gradient and the benthic fauna at both reference and sample stations was dominated by oligochaete worms and chironomid midge larvae. Taxonomic richness at individual sites ranged from 4.3 to 6.7 and 6 to 10.3 at reference and sample sites, respectively. There was no significant evidence of toxicity at any location sampled. Cluster analysis showed that the benthic community structure of many of the sample stations could not be distinguished from the reference stations. Canonical correlation analysis showed there was a significant relationship between benthic fauna and metal concentration, but there was not a consistent difference between sample and reference stations. For Soda Creek, local phenomena were more significant to benthic community structure than large-scale patterns of metal accumulation. Using the Triad approach, the authors concluded there has been no adverse effect of metal concentrations on the benthic community of Soda Creek.« less
Global GNSS processing based on the raw observation approach
NASA Astrophysics Data System (ADS)
Strasser, Sebastian; Zehentner, Norbert; Mayer-Gürr, Torsten
2017-04-01
Many global navigation satellite system (GNSS) applications, e.g. Precise Point Positioning (PPP), require high-quality GNSS products, such as precise GNSS satellite orbits and clocks. These products are routinely determined by analysis centers of the International GNSS Service (IGS). The current processing methods of the analysis centers make use of the ionosphere-free linear combination to reduce the ionospheric influence. Some of the analysis centers also form observation differences, in general double-differences, to eliminate several additional error sources. The raw observation approach is a new GNSS processing approach that was developed at Graz University of Technology for kinematic orbit determination of low Earth orbit (LEO) satellites and subsequently adapted to global GNSS processing in general. This new approach offers some benefits compared to well-established approaches, such as a straightforward incorporation of new observables due to the avoidance of observation differences and linear combinations. This becomes especially important in view of the changing GNSS landscape with two new systems, the European system Galileo and the Chinese system BeiDou, currently in deployment. GNSS products generated at Graz University of Technology using the raw observation approach currently comprise precise GNSS satellite orbits and clocks, station positions and clocks, code and phase biases, and Earth rotation parameters. To evaluate the new approach, products generated using the Global Positioning System (GPS) constellation and observations from the global IGS station network are compared to those of the IGS analysis centers. The comparisons show that the products generated at Graz University of Technology are on a similar level of quality to the products determined by the IGS analysis centers. This confirms that the raw observation approach is applicable to global GNSS processing. Some areas requiring further work have been identified, enabling future improvements of the method.
Chilean Tsunami Rocks the Ross Ice Shelf
NASA Astrophysics Data System (ADS)
Bromirski, P. D.; Gerstoft, P.; Chen, Z.; Stephen, R. A.; Diez, A.; Arcas, D.; Wiens, D.; Aster, R. C.; Nyblade, A.
2016-12-01
The response of the Ross Ice Shelf (RIS) to the September 16, 2015 9.3 Mb Chilean earthquake tsunami (> 75 s period) and infragravity (IG) waves (50 - 300 s period) were recorded by a broadband seismic array deployed on the RIS from November 2014 to November 2015. The array included two linear transects, one approximately orthogonal to the shelf front extending 430 km southward toward the grounding zone, and an east-west transect spanning the RIS roughly parallel to the front about 100 km south of the ice edge (https://scripps.ucsd.edu/centers/iceshelfvibes/). Signals generated by both the tsunami and IG waves were recorded at all stations on floating ice, with little ocean wave-induced energy reaching stations on grounded ice. Cross-correlation and dispersion curve analyses indicate that tsunami and IG wave-generated signals propagate across the RIS at gravity wave speeds (about 70 m/s), consistent with coupled water-ice flexural-gravity waves propagating through the ice shelf from the north. Gravity wave excitation at periods > 100 s is continuously observed during the austral winter, providing mechanical excitation of the RIS throughout the year. Horizontal displacements are typically about 3 times larger than vertical displacements, producing extensional motions that could facilitate expansion of existing fractures. The vertical and horizontal spectra in the IG band attenuate exponentially with distance from the front. Tsunami model data are used to assess variability of excitation of the RIS by long period gravity waves. Substantial variability across the RIS roughly parallel to the front is observed, likely resulting from a combination of gravity wave amplitude variability along the front, signal attenuation, incident angle of the wave forcing at the front that depends on wave generation location as well as bathymetry under and north of the shelf, and water layer and ice shelf thickness and properties.
Luís, Mariana; Brites, Luísa; Fernandes, Bruno; Jesus, Diogo; Santiago, Tânia; Serra, Sara; Rovisco, João; Carvalho, Lina; da Silva, José António P; Malcata, Armando
2018-05-12
Vascular involvement in IgG4-related disease (IgG4-RD), is a well-recognized feature and large vessel commitment, especially the aorta, can be the only manifestation of the disease. Being a newly recognized disease, its diagnosis and workup still represents a challenge in clinical practice. A 47-year-old-man with two aortic aneurysms ruptures, one at abdominal and the other at thoracic level, was referred to our rheumatology department. The initial analysis of the surgical specimen obtained 3 years earlier revealed a nonspecific aortitis. Re-evaluation of the biopsy with immunohistology now demonstrated the presence of IgG4 deposits. Evidence-based recommendations regarding diagnosis, treatment and follow-up of IgG4-related large-vessel involvement are lacking. In this particular case, histopathology were crucial. The authors review and discuss vascular involvement in IgG4-RD and respective treatment options.
Truly selective primary IgM deficiency is probably very rare.
Janssen, L M A; Macken, T; Creemers, M C W; Pruijt, J F M; Eijk, J J J; de Vries, E
2018-02-01
Isolated decreased serum-immunoglobulin (Ig)M has been associated with severe and/or recurrent infections, atopy and autoimmunity. However, the reported high prevalence of clinical problems in IgM-deficient patients may reflect the skewed tertiary centre population studied so far. Also, many papers on IgM deficiency have included patients with more abnormalities than simply IgM-deficiency. We studied truly selective primary IgM deficiency according to the diagnostic criteria of the European Society for Immunodeficiencies (ESID) (true sIgMdef) by reviewing the literature (261 patients with primary decreased serum-IgM in 46 papers) and analysing retrospectively all patients with decreased serum-IgM in a large teaching hospital in 's-Hertogenbosch, the Netherlands [1 July 2005-23 March 2016; n = 8049 IgM < 0·4 g/l; n = 2064 solitary (IgG+IgA normal/IgM < age-matched reference)]. A total of 359 of 2064 (17%) cases from our cohort had primary isolated decreased serum-IgM, proven persistent in 45 of 359 (13%) cases; their medical charts were reviewed. Our main finding is that true sIgMdef is probably very rare. Only six of 261 (2%) literature cases and three of 45 (7%) cases from our cohort fulfilled the ESID criteria completely; 63 of 261 (24%) literature cases also had other immunological abnormalities and fulfilled the criteria for unclassified antibody deficiencies (unPAD) instead. The diagnosis was often uncertain (possible sIgMdef): data on IgG subclasses and/or vaccination responses were lacking in 192 of 261 (74%) literature cases and 42 of 45 (93%) cases from our cohort. Our results also illustrate the clinical challenge of determining the relevance of a serum sample with decreased IgM; a larger cohort of true sIgMdef patients is needed to explore fully its clinical consequences. The ESID online Registry would be a useful tool for this. © 2017 British Society for Immunology.
Persistent Lymphadenopathy due to IgG4-Related Disease
2012-10-01
worsened, she was referred to Infectious Disease who entertained a broad differential including Kikuchi’s syndrome, Epstein - Barr virus (EBV...anti-Smith; EBV = Epstein - Barr virus , CMV: cytomegalovirus, HBs Ag = hepatitis B surface antigen, and HBc Ab: hepatitis B core antibody IgG, HBs Ab...plasmosis, HIV, and mycobacterium), lymphoma/leukemia, metastatic neoplasia, systemic lupus erythematous, Castle- man’s disease , autoimmune
Genetics Home Reference: autosomal dominant hyper-IgE syndrome
... binding domain of STAT3 cause hyper-IgE syndrome. Nature. 2007 Aug 30;448(7157):1058-62. Epub 2007 Aug 5. Citation on PubMed Renner ED, Torgerson TR, Rylaarsdam S, Añover-Sombke S, Golob K, LaFlam T, Zhu Q, Ochs HD. STAT3 mutation in the original patient with Job's syndrome. N Engl J Med. 2007 Oct 18; ...
Butler, J E; Wertz, N; Sun, X-Z; Lunney, J K; Muyldermans, S
2013-01-01
The immunoglobulin (Ig) genes of many vertebrates have been characterized but IgG subclasses, IgD and IgE proteins are only available for three species in which plasmacytomas occur. This creates a major problem in the production and specificity verification of diagnostic anti-Ig reagents for the vast majority of mammals. We describe a novel solution using the swine system with its eleven different variants of IgG. It involves the in vitro synthesis of chimeric porcine-camelid heavy chain antibodies (HCAbs) that do not require light chains and therefore only a single transfection vector. The expressed chimeric HCAbs are comprised of the camelid VHH domain encoding specificity for lysozyme and the hinge, CH2 and CH3 domains of the various porcine IgGs. These HCAb retain their antigenic integrity and their ability to recognize lysozyme. The engineered specificity assures that these HCAb can be immobilized in native configuration when used for testing the specificity of anti-swine IgG antibodies. Comparative data to illustrate the importance of this point are provided. These are now available for use in hybridoma selection and as reference standards for evaluating the specificity of currently available anti-swine IgG antibodies. Copyright © 2012 Elsevier Ltd. All rights reserved.
Spontaneous remission of IgA nephropathy associated with resolution of hepatitis A.
Han, Seung Hyeok; Kang, Ea Wha; Kie, Jeong Hae; Yoo, Tae Hyun; Choi, Kyu Hun; Han, Dae-Suk; Kang, Shin-Wook
2010-12-01
Although most cases of immunoglobulin A (IgA) nephropathy are idiopathic, several diseases are associated with IgA nephropathy. Of these, chronic liver disease resulting from hepatitis B or C virus infection has been reported as a secondary cause of IgA nephropathy. Recently, hepatitis A virus (HAV)-associated kidney disease has received attention because acute kidney injury can occur as a complication of HAV infection, generally caused by acute tubular necrosis or interstitial nephritis. However, unlike IgA nephropathy related to hepatitis B or C, HAV-associated IgA nephropathy is extremely rare and long-term outcomes have not been reported yet. We describe a case of spontaneous remission of IgA nephropathy associated with serologically documented HAV infection. The patient presented with microhematuria and moderate proteinuria, but acute kidney injury did not occur during active hepatic injury. Kidney biopsy specimens clearly showed mesangial IgA deposits with intact tubules and interstitium. Serum liver enzyme levels returned to reference values 1 month after the onset of acute hepatitis, but urinary protein excretion remained increased. Approximately 1 year later, urinary abnormalities were resolved and a second biopsy showed no mesangial IgA deposits. These findings suggest that IgA nephropathy can transiently accompany HAV infection, but may not progress to chronic glomerulonephritis after recovery from HAV. Copyright © 2010 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
The fast-recycling receptor Megalin defines the apical recycling pathway of epithelial cells
Perez Bay, Andres E.; Schreiner, Ryan; Benedicto, Ignacio; Paz Marzolo, Maria; Banfelder, Jason; Weinstein, Alan M.; Rodriguez-Boulan, Enrique J.
2016-01-01
The basolateral recycling and transcytotic pathways of epithelial cells were previously defined using markers such as transferrin (TfR) and polymeric IgA (pIgR) receptors. In contrast, our knowledge of the apical recycling pathway remains fragmentary. Here we utilize quantitative live-imaging and mathematical modelling to outline the recycling pathway of Megalin (LRP-2), an apical receptor with key developmental and renal functions, in MDCK cells. We show that, like TfR, Megalin is a long-lived and fast-recycling receptor. Megalin enters polarized MDCK cells through segregated apical sorting endosomes and subsequently intersects the TfR and pIgR pathways at a perinuclear Rab11-negative compartment termed common recycling endosomes (CRE). Whereas TfR recycles to the basolateral membrane from CRE, Megalin, like pIgR, traffics to subapical Rab11-positive apical recycling endosomes (ARE) and reaches the apical membrane in a microtubule- and Rab11-dependent manner. Hence, Megalin defines the apical recycling pathway of epithelia, with CRE as its apical sorting station. PMID:27180806
Online, automatic, ionospheric maps: IRI-PLAS-MAP
NASA Astrophysics Data System (ADS)
Arikan, F.; Sezen, U.; Gulyaeva, T. L.; Cilibas, O.
2015-04-01
Global and regional behavior of the ionosphere is an important component of space weather. The peak height and critical frequency of ionospheric layer for the maximum ionization, namely, hmF2 and foF2, and the total number of electrons on a ray path, Total Electron Content (TEC), are the most investigated and monitored values of ionosphere in capturing and observing ionospheric variability. Typically ionospheric models such as International Reference Ionosphere (IRI) can provide electron density profile, critical parameters of ionospheric layers and Ionospheric electron content for a given location, date and time. Yet, IRI model is limited by only foF2 STORM option in reflecting the dynamics of ionospheric/plasmaspheric/geomagnetic storms. Global Ionospheric Maps (GIM) are provided by IGS analysis centers for global TEC distribution estimated from ground-based GPS stations that can capture the actual dynamics of ionosphere and plasmasphere, but this service is not available for other ionospheric observables. In this study, a unique and original space weather service is introduced as IRI-PLAS-MAP from http://www.ionolab.org
Abnormal cerebrospinal fluid protein indices in schizophrenia.
Kirch, D G; Kaufmann, C A; Papadopoulos, N M; Martin, B; Weinberger, D R
1985-10-01
Determinations of albumin and immunoglobulin G (IgG) were performed in paired cerebrospinal fluid (CSF) and serum samples from 24 subjects with schizophrenia. These determinations allowed calculation of two indices, one that is an indicator of integrity of the blood-brain barrier and the other a measure of selective IgG production within the central nervous system (CNS). In comparison with previously determined reference values, 7 of 24 (29%) subjects showed increased blood-brain barrier permeability, and 8 of 24 (33%) demonstrated elevated endogenous CNS IgG production. One of these eight also demonstrated oligoclonal banding on high-resolution protein electrophoresis of the CSF.
Villard, O; Cimon, B; L'Ollivier, C; Fricker-Hidalgo, H; Godineau, N; Houze, S; Paris, L; Pelloux, H; Villena, I; Candolfi, E
2016-12-01
Toxoplasmosis, a benign infection, is asymptomatic or paucisymptomatic in over 80% of cases, except in immunocompetent patients suffering from ocular toxoplasmosis or in immunocompromised patients with opportunistic or congenital toxoplasmosis. Diagnosis is based mainly on serology testing. Thus, we compared the performance of the nine most commonly used commercial automated or semiautomated immunoassays for IgG and IgM Toxoplasma gondii antibody detection, that is, the Advia Centaur, Architect, AxSYM, Elecsys, Enzygnost, Liaison, Platelia, VIDAS, and VIDIA assays. The assays were conducted on four panels of serum samples derived during routine testing from patients with an interfering disease and who exhibited a low IgG antibody level in one of two clinical settings, namely, acute or chronic toxoplasmosis. As a result, IgG sensitivities ranged from 97.1% to 100%, and IgG specificities ranged from 99.5% to 100%. For IgG quantification, strong differences in IgG titers (expressed in IU/ml) were noted depending on the assay used. IgM sensitivities ranged from 65% to 97.9%, and IgM specificities ranged from 92.6% to 100%. For defining the best serological strategies to be implemented, it appears crucial to compare the diagnostic performance of the different tests with respect to their specificity and sensitivity in detecting the presence of IgG and IgM antibodies. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Cimon, B.; L'Ollivier, C.; Fricker-Hidalgo, H.; Godineau, N.; Houze, S.; Paris, L.; Pelloux, H.; Villena, I.
2016-01-01
Toxoplasmosis, a benign infection, is asymptomatic or paucisymptomatic in over 80% of cases, except in immunocompetent patients suffering from ocular toxoplasmosis or in immunocompromised patients with opportunistic or congenital toxoplasmosis. Diagnosis is based mainly on serology testing. Thus, we compared the performance of the nine most commonly used commercial automated or semiautomated immunoassays for IgG and IgM Toxoplasma gondii antibody detection, that is, the Advia Centaur, Architect, AxSYM, Elecsys, Enzygnost, Liaison, Platelia, VIDAS, and VIDIA assays. The assays were conducted on four panels of serum samples derived during routine testing from patients with an interfering disease and who exhibited a low IgG antibody level in one of two clinical settings, namely, acute or chronic toxoplasmosis. As a result, IgG sensitivities ranged from 97.1% to 100%, and IgG specificities ranged from 99.5% to 100%. For IgG quantification, strong differences in IgG titers (expressed in IU/ml) were noted depending on the assay used. IgM sensitivities ranged from 65% to 97.9%, and IgM specificities ranged from 92.6% to 100%. For defining the best serological strategies to be implemented, it appears crucial to compare the diagnostic performance of the different tests with respect to their specificity and sensitivity in detecting the presence of IgG and IgM antibodies. PMID:27733631
Murthy, Vijaya; Willis, Rohan; Romay-Penabad, Zurina; Ruiz-Limón, Patricia; Martínez-Martínez, Laura A; Jatwani, Shraddha; Jajoria, Praveen; Seif, Alan; Alarcón, Graciela S; Papalardo, Elizabeth; Liu, Jigna; Vilá, Luis M; McGwin, Gerald; McNearney, Terry A; Maganti, Rashmi; Sunkureddi, Prashanth; Parekh, Trisha; Tarantino, Michael; Akhter, Ehtisham; Fang, Hong; Gonzalez, Emilio B; Binder, Walter R; Norman, Gary L; Shums, Zakera; Teodorescu, Marius; Reveille, John D; Petri, Michelle; Pierangeli, Silvia S
2013-12-01
To examine the prevalence of isolated IgA anti-β2 -glycoprotein I (anti-β2 GPI) positivity and the association of these antibodies, and a subgroup that bind specifically to domain IV/V of β2 GPI, with clinical manifestations of the antiphospholipid syndrome (APS) in 3 patient groups and to evaluate the pathogenicity of IgA anti-β2 GPI in a mouse model of thrombosis. Patients with systemic lupus erythematosus (SLE) from a multiethnic, multicenter cohort (LUpus in MInorities, NAture versus nurture [LUMINA]) (n = 558), patients with SLE from the Hopkins Lupus Cohort (n = 215), and serum samples referred to the Antiphospholipid Standardization Laboratory (APLS) (n = 5,098) were evaluated. IgA anti-β2 GPI titers and binding to domain IV/V of β2 GPI were examined by enzyme-linked immunosorbent assay (ELISA). CD1 mice were inoculated with purified IgA anti-β2 GPI antibodies, and surgical procedures and ELISAs were performed to evaluate thrombus development and tissue factor (TF) activity. A total of 198 patients were found to be positive for IgA anti-β2 GPI isotype, and 57 patients were positive exclusively for IgA anti-β2 GPI antibodies. Of these, 13 of 23 patients (56.5%) in the LUMINA cohort, 17 of 17 patients (100%) in the Hopkins cohort, and 10 of 17 patients (58.9%) referred to APLS had at least one APS-related clinical manifestation. Fifty-four percent of all the IgA anti-β2 GPI-positive serum samples reacted with domain IV/V of anti-β2 GPI, and 77% of those had clinical features of APS. Isolated IgA anti-β2 GPI positivity was associated with an increased risk of arterial thrombosis (P < 0.001), venous thrombosis (P = 0.015), and all thrombosis (P < 0.001). The association between isolated IgA anti-β2 GPI and arterial thrombosis (P = 0.0003) and all thrombosis (P = 0.0003) remained significant after adjusting for other risk factors for thrombosis. In vivo mouse studies demonstrated that IgA anti-β2 GPI antibodies induced significantly larger thrombi and higher TF levels compared to controls. Isolated IgA anti-β2 GPI-positive titers may identify additional patients with clinical features of APS. Testing for these antibodies when other antiphospholipid tests are negative and APS is suspected is recommended. IgA anti-β2 GPI antibodies directed to domain IV/V of β2 GPI represent an important subgroup of clinically relevant antiphospholipids. Copyright © 2013 by the American College of Rheumatology.
Value of Isolated IgA anti-β2GPI Positivity in the Diagnosis of the Antiphospholipid Syndrome
Murthy, Vijaya; Willis, Rohan; Romay-Penabad, Zurina; Ruiz-Limón, Patricia; Martínez-Martínez, Laura A.; Jatwani, Shraddha; Jajoria, Praveen; Seif, Alan; Alarcón, Graciela S.; Papalardo, Elizabeth; Liu, Jigna; Vilá, Luis M.; McGwin, Gerald; McNearney, Terry A.; Maganti, Rashmi; Sunkureddi, Prashanth; Parekh, Trisha; Tarantino, Michael; Akhter, Ehtisham; Fang, Hong; Gonzalez, Emilio B.; Binder, Walter R.; Norman, Gary L.; Shums, Zakera; Teodorescu, Marius; Reveille, John D.; Petri, Michelle; Pierangeli, Silvia S.
2014-01-01
Purpose To examine the prevalence of isolated IgA anti-β2Glycoprotein I (anti-β2GPI) positivity and the association of these antibodies, and a subgroup that bind specifically to domain IV/V of β2GPI, with clinical manifestations of the Antiphospholipid Syndrome (APS) in three patients groups. The pathogenicity of IgA anti-β2GPI was also evaluated in a mouse model of thrombosis. Methods Patients with systemic lupus erythematosus (SLE) from a multiethnic, multicenter cohort (LUpus in MInorities, NAture versus nurture [LUMINA]) (n=558), patients with SLE from the Hopkins Lupus Cohort (n=215), and serum samples referred to the Antiphospholipid Standardization Laboratory (APLS) (n=5,098) were evaluated. IgA anti-β2GPI titers and binding to domain IV/V of β2GPI were examined by enzyme-linked immunosorbent assay (ELISA). CD1 mice were inoculated with purified IgA anti- β2GPI antibodies, and surgical procedures and ELISAs were performed to evaluate thrombus development and tissue factor (TF) activity. Results A total of 198 patients were found to be positive for IgA anti-β2GPI isotype, and 57 patients were positive exclusively for IgA anti-β2GPI antibodies. Of these, 13 of 23 patients (56.5%) in the LUMINA cohort, 17 of 17 patients (100%) in the Hopkins cohort, and 10 of 17 patients (58.9%) referred to APLS had at least one APS-related clinical manifestation. Fifty-four percent of all the IgA anti-β2GPI positive serum samples reacted with domain IV/V of anti-β2GPI, and 77% of those had clinical features of APS. Isolated IgA anti-β2GPI positivity was associated with an increased risk for arterial thrombosis (p<0.001), venous thrombosis (p=0.015) and all thrombosis (p<0.001). The association between isolated IgA anti-β2GPI and arterial thrombosis (p=0.0003) and all thrombosis (p=0.0003) remained significant after adjusting for other risk factors for thrombosis. In vivo mouse studies demonstrated that IgA anti-β2GPI antibodies induced significantly larger thrombi and higher TF levels compared to controls. Conclusion Isolated IgA anti-β2GPI positive titers may identify additional patients with clinical features of APS. Testing for these antibodies when other antiphospholipid (aPL) tests are negative and APS is suspected is recommended. IgA anti-β2GPI antibodies directed to domain IV/V of β2GPI represent an important subgroup of clinically relevant antiphospholipids. PMID:23983008
Burns, J; Hou, S; Riley, C B; Shaw, R A; Jewett, N; McClure, J T
2014-01-01
Rapid, economical, and quantitative assays for measurement of camelid serum immunoglobulin G (IgG) are limited. In camelids, failure of transfer of maternal immunoglobulins has a reported prevalence of up to 20.5%. An accurate method for quantifying serum IgG concentrations is required. To develop an infrared spectroscopy-based assay for measurement of alpaca serum IgG and compare its performance to the reference standard radial immunodiffusion (RID) assay. One hundred and seventy-five privately owned, healthy alpacas. Eighty-two serum samples were collected as convenience samples during routine herd visits whereas 93 samples were recruited from a separate study. Serum IgG concentrations were determined by RID assays and midinfrared spectra were collected for each sample. Fifty samples were set aside as the test set and the remaining 125 training samples were employed to build a calibration model using partial least squares (PLS) regression with Monte Carlo cross validation to determine the optimum number of PLS factors. The predictive performance of the calibration model was evaluated by the test set. Correlation coefficients for the IR-based assay were 0.93 and 0.87, respectively, for the entire data set and test set. Sensitivity in the diagnosis of failure of transfer of passive immunity (FTPI) ([IgG] <1,000 mg/dL) was 71.4% and specificity was 100% for the IR-based method (test set) as gauged relative to the RID reference method assay. This study indicated that infrared spectroscopy, in combination with chemometrics, is an effective method for measurement of IgG in alpaca serum. Copyright © 2014 by the American College of Veterinary Internal Medicine.
Visitsunthorn, Nualanong; Visitsuntho, Kittipos; Pacharn, Punchama; Jirapongsananuruk, Orathai; Bunnag, Chaweewan
2017-12-01
Allergen extracts may be different due to the difference in dissemination of allergen-containing species in various geographical areas. Therefore, we wish to develop our own extracts to ensure the precision and quality of diagnosis. To compare the efficacy and safety of our locally prepared pollen allergen extracts to imported ones, using skin prick testing (SPT) and serum specific IgE (sIgE) as references. This prospective, randomized, double-blinded, self-controlled study was performed in respiratory allergic adult volunteers who are sensitized to at least one kind of pollen. Each subject was pricked with our Bermuda grass, Johnson grass and careless weed pollen allergen extracts, and also with the imported ones. sIgE levels were measured by using ImmunoCAP?. In 68 volunteers, our Bermuda, Johnson and careless weed extracts showed 91.2%, 45.6% and 54.4% positive SPTs, respectively, while for the imported ones 73.5%, 45.6% and 54.4% SPTs were positive, respectively. No adverse reaction was found in all procedures. The concentration of 10,000 BAU/mL of Bermuda grass, 1 : 20 w/v or 10,000 PNU/mL of Johnson grass and 1 : 40 w/v or 10,000 PNU/mL of careless weed yielded the most positive SPT results. There was no significant difference in mean wheal diameter (MWD) yielded from using local and imported extracts. Significant correlation was found between MWDs of imported pollen extracts and serum sIgE levels (p < 0.01). No significant difference between SPT results of local and imported pollen allergen extracts was found. Significant correlation was found between MWDs of imported pollen extract SPT and serum sIgE levels.
Gabriel, Martin; Adomeh, Donatus I; Ehimuan, Jacqueline; Oyakhilome, Jennifer; Omomoh, Emmanuel O; Ighodalo, Yemisi; Olokor, Thomas; Bonney, Kofi; Pahlmann, Meike; Emmerich, Petra; Lelke, Michaela; Brunotte, Linda; Ölschläger, Stephan; Thomé-Bolduan, Corinna; Becker-Ziaja, Beate; Busch, Carola; Odia, Ikponmwosa; Ogbaini-Emovon, Ephraim; Okokhere, Peter O; Okogbenin, Sylvanus A; Akpede, George O; Schmitz, Herbert; Asogun, Danny A; Günther, Stephan
2018-03-01
The classical method for detection of Lassa virus-specific antibodies is the immunofluorescence assay (IFA) using virus-infected cells as antigen. However, IFA requires laboratories of biosafety level 4 for assay production and an experienced investigator to interpret the fluorescence signals. Therefore, we aimed to establish and evaluate enzyme-linked immunosorbent assays (ELISA) using recombinant Lassa virus nucleoprotein (NP) as antigen. The IgM ELISA is based on capturing IgM antibodies using anti-IgM, and the IgG ELISA is based on capturing IgG antibody-antigen complexes using rheumatoid factor or Fc gamma receptor CD32a. Analytical and clinical evaluation was performed with 880 sera from Lassa fever endemic (Nigeria) and non-endemic (Ghana and Germany) areas. Using the IFA as reference method, we observed 91.5-94.3% analytical accuracy of the ELISAs in detecting Lassa virus-specific antibodies. Evaluation of the ELISAs for diagnosis of Lassa fever on admission to hospital in an endemic area revealed a clinical sensitivity for the stand-alone IgM ELISA of 31% (95% CI 25-37) and for combined IgM/IgG detection of 26% (95% CI 21-32) compared to RT-PCR. The specificity of IgM and IgG ELISA was estimated at 96% (95% CI 93-98) and 100% (95% CI 99-100), respectively, in non-Lassa fever patients from non-endemic areas. In patients who seroconverted during follow-up, Lassa virus-specific IgM and IgG developed simultaneously rather than sequentially. Consistent with this finding, isolated IgM reactivity, i.e. IgM in the absence of IgG, had no diagnostic value. The ELISAs are not equivalent to RT-PCR for early diagnosis of Lassa fever; however, they are of value in diagnosing patients at later stage. The IgG ELISA may be useful for epidemiological studies and clinical trials due its high specificity, and the higher throughput rate and easier operation compared to IFA.
Prince, Harry E; Seaton, Brent L; Matud, Jose L; Batterman, Hollis J
2015-03-01
Since first reported in the Americas in December 2013, chikungunya virus (CHIKV) infections have been documented in travelers returning from the Caribbean, with many cases identified by CHIKV antibody and/or RNA testing at our laboratory. We used our large data set to characterize the relationship between antibody titers and RNA detection and to estimate IgM persistence. CHIKV RNA was measured by nucleic acid amplification and CHIKV IgG/IgM by indirect immunofluorescence. Of the 1,306 samples submitted for RNA testing in January through September 2014, 393 (30%) were positive; for 166 RNA-positive samples, CHIKV antibody testing was also ordered, and 84% were antibody negative. Of the 6,971 sera submitted for antibody testing in January through September 2014, 1,811 (26%) were IgM positive; 1,461 IgM positives (81%) were also IgG positive. The relationship between the CHIKV antibody titers and RNA detection was evaluated using 376 IgM-positive samples (138 with RNA testing ordered and 238 deidentified and tested for RNA). RNA detection showed no significant association with the IgM titer but was inversely related to the IgG titer; 63% of the IgG negative sera were RNA positive, compared to 36% of sera with low IgG titers (1:10 to 1:80) and 16% with IgG titers of ≥1:160. Using second-sample results from 62 seroconverters, we estimated that CHIKV IgM persists for 110 days (95% confidence interval, 78 to 150 days) after the initial antibody-negative sample. These findings indicate that (i) RNA detection is more sensitive than antibody detection early in CHIKV infection, (ii) in the absence of RNA results, the IgG titer of the IgM-positive samples may be a useful surrogate for viremia, and (iii) CHIKV IgM persists for approximately 4 months after symptom onset. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Multi-modal antigen specific therapy for autoimmunity.
Legge, K L; Bell, J J; Li, L; Gregg, R; Caprio, J C; Zaghouani, H
2001-10-01
Peripheral tolerance, represents an attractive strategy to down-regulate previously activated T cells and suppress an ongoing disease. Herein, immunoglobulins (Igs) were used to deliver self and altered self peptides for efficient peptide presentation without costimulation to test for modulation of experimental allergic encephalomyelitis (EAE). Accordingly, the encephalitogenic proteolipid protein (PLP) sequence 139-151 (referred to as PLP1) and an altered form of PLP1 known as PLP-LR were genetically expressed on Igs and the resulting Ig-PLP1 and Ig-PLP-LR were tested for efficient presentation of the peptides and for amelioration of ongoing EAE. Evidence is presented indicating that Ig-PLP1 as well as Ig-PLP-LR given in saline to mice with ongoing clinical EAE suppresses subsequent relapses. However, aggregation of both chimeras allows crosslinking of Fcgamma receptors (FcgammaRs) and induction of IL-10 production by APCs but does not promote the up-regulation of costimulatory molecules. Consequently, IL-10 displays bystander suppression and synergizes with presentation without costimulation to drive effective modulation of EAE. As Ig-PLP1 is more potent than Ig-PLP-LR in the down-regulation of T cells, we conclude that peptide affinity plays a critical role in this multi-modal approach of T cell modulation.
IgG4-Related Kidney Disease: Report of a Case Presenting as a Renal Mass.
Bianchi, Daniele; Topazio, Luca; Gaziev, Gabriele; Iacovelli, Valerio; Bove, Pierluigi; Mauriello, Alessandro; Finazzi Agrò, Enrico
2017-01-01
IgG4-related disease (IgG4-RD) is a nosological entity defined as a chronic immune-mediated fibro-inflammatory condition characterized by a tendency to form tumefactive, tissue-destructive lesions or by organ failure. Urologic involvement in IgG4-RD has been described in some short series of patients and in isolated case reports, most often involving the kidneys in so-called IgG4-related kidney disease (IgG4-RKD). The disease can occasionally mimic malignancies and is at risk of being misdiagnosed due to its rarity. We report the case of a 56-year-old man presenting with a right renal mass suspected of being malignant. Laboratory tests showed normal creatinine levels, a high erythrocyte sedimentation rate, and high levels of C-reactive protein and microalbuminuria. The patient underwent radical right nephroureterectomy and histopathologic examination revealed features proving IgG4-RKD. He was therefore referred to immunologists. Typical clinical presentation of IgG4-RKD includes altered renal function with inconstant or no radiologic findings. Conversely, in the case we presented, a single nodule was detected upon imaging evaluation, thus mimicking malignancy. This raises the issue of a proper differential diagnosis. A multidisciplinary approach can be useful, although in clinical practice the selection of patients suspected of having IgG4-RKD is critical in the cases presenting with a renal mass that mimics malignancy.
NASA Technical Reports Server (NTRS)
Neilan, R.; Reigber, C.; Springer, T.; Beutler, G.; Kouba, J.
1999-01-01
In December 1998, the IGS Governing Board officially changed the name of this IAG service from 'International GPS Service for Geodynamics to simply the 'International GPS Service'. This change of name reflects the fact that today the IGS supports numerous scientific projects outside the traditional geodetic and geodynamic disciplines. A number of IGS projects and working groups have been established, each concentrating on a particular science application, such as the ionosphere, atmosphere, reference frame, precise time transfer, etc. These activities are enabled and simulated by the IGS and directly contribute to the continuing development of the service. The IGS is currently poised to respond to evolving user requirements that focus on timeliness and reliability of data and products, particularly in support of a slate of Low Earth Orbiter missions over the next decade. Perspectives on the future of the IGS will be developed based on current directions as well as anticipated external influences, such as GPS satellite modernization, GLONASS, availability of global communications, and plans for the European GALILEO (Global Navigation Satellite System - GNSS). We will address development of user friendly interfaces and IGS product tutorials.
Al Sidairi, Hilal; Binkhamis, Khalifa; Jackson, Colleen; Roberts, Catherine; Heinstein, Charles; MacDonald, Jimmy; Needle, Robert; Hatchette, Todd F; LeBlanc, Jason J
2017-11-01
Serology remains the mainstay for diagnosis of Epstein-Barr virus (EBV) infection. This study compared two automated platforms (BioPlex 2200 and Architect i2000SR) to test three EBV serological markers: viral capsid antigen (VCA) immunoglobulins of class M (IgM), VCA immunoglobulins of class G (IgG) and EBV nuclear antigen-1 (EBNA-1) IgG. Using sera from 65 patients at various stages of EBV disease, BioPlex demonstrated near-perfect agreement for all EBV markers compared to a consensus reference. The agreement for Architect was near-perfect for VCA IgG and EBNA-1 IgG, and substantial for VCA IgM despite five equivocal results. Since the majority of testing in our hospital was from adults with EBNA-1 IgG positive results, post-implementation analysis of an EBNA-based algorithm showed advantages over parallel testing of the three serologic markers. This small verification demonstrated that both automated systems for EBV serology had good performance for all EBV markers, and an EBNA-based testing algorithm is ideal for an adult hospital.
Hunsperger, Elizabeth A.; Yoksan, Sutee; Buchy, Philippe; Nguyen, Vinh Chau; Sekaran, Shamala Devi; Enria, Delia A.; Vazquez, Susana; Cartozian, Elizabeth; Pelegrino, Jose L.; Artsob, Harvey; Guzman, Maria G.; Olliaro, Piero; Zwang, Julien; Guillerm, Martine; Kliks, Susie; Halstead, Scott; Peeling, Rosanna W.; Margolis, Harold S.
2014-01-01
Commercially available diagnostic test kits for detection of dengue virus (DENV) non-structural protein 1 (NS1) and anti-DENV IgM were evaluated for their sensitivity and specificity and other performance characteristics by a diagnostic laboratory network developed by World Health Organization (WHO), the UNICEF/UNDP/World Bank/WHO Special Programme for Research and Training in Tropical Diseases (TDR) and the Pediatric Dengue Vaccine Initiative (PDVI). Each network laboratory contributed characterized serum specimens for the panels used in the evaluation. Microplate enzyme-linked immunosorbent assay (ELISA) and rapid diagnostic test (RDT formats) were represented by the kits. Each ELISA was evaluated by 2 laboratories and RDTs were evaluated by at least 3 laboratories. The reference tests for IgM anti-DENV were laboratory developed assays produced by the Armed Forces Research Institute for Medical Science (AFRIMS) and the Centers for Disease Control and Prevention (CDC), and the NS1 reference test was reverse transcriptase polymerase chain reaction (RT-PCR). Results were analyzed to determine sensitivity, specificity, inter-laboratory and inter-reader agreement, lot-to-lot variation and ease-of-use. NS1 ELISA sensitivity was 60–75% and specificity 71–80%; NS1 RDT sensitivity was 38–71% and specificity 76–80%; the IgM anti-DENV RDTs sensitivity was 30–96%, with a specificity of 86–92%, and IgM anti-DENV ELISA sensitivity was 96–98% and specificity 78–91%. NS1 tests were generally more sensitive in specimens from the acute phase of dengue and in primary DENV infection, whereas IgM anti-DENV tests were less sensitive in secondary DENV infections. The reproducibility of the NS1 RDTs ranged from 92-99% and the IgM anti-DENV RDTs from 88–94%. PMID:25330157
Moon view period tabulations (with station masking) for Manned Space Flight Network stations, book 1
NASA Technical Reports Server (NTRS)
Gattie, M. M.; Williams, R. L.
1970-01-01
The times during which MSFN stations can view the moon are tabulated. Station view periods for each month are given. All times and dates refer to Greenwich Mean Time. AOS and LOS refer to the center of the moon at zero degrees elevation for moon rise and set, respectively.
The effect of observing session duration on OPUS-RS results
NASA Astrophysics Data System (ADS)
Dincer Dogru, A.; Ugur Sanli, D.; Hayal, Adem G.; Berber, Mustafa
2016-04-01
Online GPS positioning software has now a widespread interest among practitioners and researchers. Researchers rescently use online software to monitor natural hazards such as landslides. The fact that this software usually employs continuously operating GPS stations of the International GNSS Service (IGS) as reference stations in the processing, the community of world-wide users is growing day by day. In the monitoring of landslides, rapid static mode of a GPS surveying is usually preferred because it is possible to have wider field coverage with only a few minutes of data and low cost ground markers. Results comparable to static positioning can be obtained with careful network design and processing strategies. Some online software such as OPUS-RS developed by the National Geodetic Survey (NGS) of the USA provides rapid static positioning engine that processes GPS data from sessions of only a few minutes. 15-minute is the recommended/standard observing session duration for OPUS-RS processing. In this study, using the CORS data operating in the US, we carried out some tests in which the observing session duration is changed from 8 through 118 minutes, and observed the accuracy change on the OPUS-RS solutions. Then we compared the results with the accuracy levels given for 15-min solutions by the NGS. We determined that there is the effect of changing observing session duration on the obtained results, and we report them in this study.
Pérez, D; Martínez-Flores, J A; Serrano, M; Lora, D; Paz-Artal, E; Morales, J M; Serrano, A
2016-10-01
In recent years, we have been witnessing increased clinical interest in the determination of IgA anti-beta 2-glycoprotein I (aB2GPI) antibodies as well as increased demand for this test. Some ELISA-based diagnostic systems for IgA aB2GPI antibodies detection are suboptimal to detect it. The aim of our study was to determine whether the diagnostic yield of modern detection systems based on automatic platforms to measure IgA aB2GPI is equivalent to that of the well-optimized ELISA-based assays. In total, 130 patients were analyzed for IgA aB2GPI by three fully automated immunoassays using an ELISA-based assay as reference. The three systems were also analyzed for IgG aB2GPI with 58 patients. System 1 was able to detect IgA aB2GPI with good sensitivity and kappa index (99% and 0.72, respectively). The other two systems had also poor sensitivity (20% and 15%) and kappa index (0.10 and 0.07), respectively. On the other hand, kappa index for IgG aB2GPI was >0.89 in the three systems. Some analytical methods to detect IgA aB2GPI are suboptimal as well as some ELISA-based diagnostic systems. It is important that the scientific community work to standardize analytical methods to determine IgA aB2GPI antibodies. © 2016 John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Fielhauer, Karl B. (Inventor); Jensen, James R. (Inventor)
2007-01-01
A system includes a remote station and a local station having a receiver. The receiver operates in an unlocked state corresponding to its best lock frequency (BLF). The local station derives data indicative of a ratio of the BLF to a reference frequency of the receiver, and telemeters the data to the remote station. The remote station estimates the BLF based on (i) the telemetered data, and (ii) a predetermined estimate of the reference frequency.
ERIC Educational Resources Information Center
Pieper, William J.; And Others
This study was initiated to design, develop, implement, and evaluate a videodisc-based simulator system, the Interactive Graphics Simulator (IGS) for 6883 Converter Flight Control Test Station training at Lowry Air Force Base, Colorado. The simulator provided a means for performing task analysis online, developing simulations from the task…
Granberg, C; Mansikka, A; Lehtonen, O P; Kujari, H; Grönfors, R; Nurmi, H; Räihä, I; Ståhlberg, M R; Leino, R
1993-01-01
We evaluated the performance of new enzyme immunoassay (EIA) kits (Pyloriset; Orion Corporation, Orion Diagnostica, Espoo, Finland) for the detection of immunoglobulin G (IgG) and IgA antibodies to Helicobacter pylori in serum. Serum samples from 195 patients with upper abdominal complaints were collected. Biopsy specimens of the gastric mucosae were taken for histological analysis and bacterial culture. The sensitivity, specificity, and positive and negative predictive values, and efficacy of the Pyloriset EIA-G in detecting IgG antibodies to H. pylori were 92, 84, 88, 90, and 89%, respectively, when compared with those of the reference methods used. The corresponding data for detection of IgA antibodies were 80, 89, 89, 79, and 84%, respectively. The overall prevalence of defined H. pylori positivity was 54%. Moreover, the antibody tests showed a very good correlation with the biopsy findings. IgG antibodies were found in 93% of sera from patients with documented gastritis and H. pylori positivity, whereas only 4% of the sera from patients with documented gastritis and H. pylori-negative patients was positive. The results obtained for IgA antibodies were 81 and 6%, respectively. We conclude that the Pyloriset EIA-G, the test for IgG antibodies, is a good and reliable test for the detection of antibodies to H. pylori and as an indication of H. pylori infection. The determination of IgA antibodies may be used as a test that complements the IgG antibody assay. PMID:8314985
Effect of chronic restraint stress on inhibitory gating in the auditory cortex of rats.
Ma, Lanlan; Li, Wai; Li, Sibin; Wang, Xuejiao; Qin, Ling
2017-05-01
A fundamental adaptive mechanism of auditory function is inhibitory gating (IG), which refers to the attenuation of neural responses to repeated sound stimuli. IG is drastically impaired in individuals with emotional and cognitive impairments (i.e. posttraumatic stress disorder). The objective of this study was to test whether chronic stress impairs the IG of the auditory cortex (AC). We used the standard two-tone stimulus paradigm and examined the parametric qualities of IG in the AC of rats by recording the electrophysiological signals of a single-unit and local field potential (LFP) simultaneously. The main results of this study were that most of the AC neurons showed a weaker response to the second tone than to the first tone, reflecting an IG of the repeated input. A fast negative wave of LFP showed consistent IG across the sampled AC sites, whereas a slow positive wave of LFP had less IG effect. IG was diminished following chronic restraint stress at both, the single-unit and LFP level, due to the increase in response to the second tone. This study provided new evidence that chronic stress disrupts the physiological function of the AC. Lay Summary The effects of chronic stress on IG were investigated by recording both, single-unit spike and LFP activities, in the AC of rats. In normal rats, most of the single-unit and N25 LFP activities in the AC showed an IG effect. IG was diminished following chronic restraint stress at both, the single-unit and LFP level.
Vojdani, Aristo
2005-05-01
IgG and IgE antibodies against Stachybotrys extract have been reported in allergic patients and residents of water-damaged buildings. Detection of these antibodies in blood was partially attributed to cross-reacting proteins from other fungi. There is a need for a specific method to detect antibodies against characteristic components of S. chartarum. We measured IgG and IgE antibodies against Stachybotrys hemolysin and proteinase-Stachyrase-A by ELISA and ELISA-inhibition techniques. Of 50 reference sera with IgE greater than 500 IU ml and positive against different mold extracts used in this study, significant elevation in IgG or IgE antibodies against S. chartarum extract was present in 25 and 21 specimens. Of these specimens 20 (80%) and 10 (40%) were positive for IgG anti-Stachybotrys hemolysin and anti-Stachyrase-A, while 8 out of 21 sera (38%) and 17 out of 21 (81%) specimens were positive for IgE anti-Stachybotrys hemolysin and anti-Stachyrase-A respectively. Inhibition studies using Stachybotrys hemolysin and Stachyrase-A at a concentration of 50 microg/ml prevented binding of anti-Stachybotrys to S. chartarum extract. Detection of IgG as well as IgE antibodies against Stachybotrys hemolysin and Stachyrase-A and inhibition of anti-Stachybotrys binding to Stachybotrys antigens indicate that Stachybotrys hemolysin and Stachyrase-A are two major antigenic components of S. chartarum extract, which can be used in antibody assays. Measurement of antibodies against these characteristic components of S. chartarum may be considered for demonstration of exposure and possibly allergy to the fungus.
Precise Clock Solutions Using Carrier Phase from GPS Receivers in the International GPS Service
NASA Technical Reports Server (NTRS)
Zumberge, J. F.; Jefferson, D. C.; Stowers, D. A.; Tjoelker, R. L.; Young, L. E.
1999-01-01
As one of its activities as an Analysis Center in the International GPS Service (IGS), the Jet Propulsion Laboratory (JPL) uses data from a globally distributed network of geodetic-quality GPS receivers to estimate precise clock solutions, relative to a chosen reference, for both the GPS satellites and GPS receiver internal clocks, every day. The GPS constellation and ground network provide geometrical strength resulting in formal errors of about 100 p sec for these estimates. Some of the receivers in the global IGS network contain high quality frequency references, such as hydrogen masers. The clock solutions for such receivers are smooth at the 20-p sec level on time scales of a few minutes. There are occasional (daily to weekly) shifts at the microsec level, symptomatic of receiver resets, and 200-p sec-level discontinuities at midnight due to 1-day processing boundaries. Relative clock solutions among 22 IGS sites proposed as "fiducial" in the IGS/BIPM pilot project have been examined over a recent 4-week period. This allows a quantitative measure of receiver reset frequency as a function of site. For days and-sites without resets, the Allan deviation of the relative clock solutions is also computed for subdaily values of tau..
NASA Astrophysics Data System (ADS)
Brown, Steven; Bilitza, Dieter; Yiǧit, Erdal
2018-06-01
A new monthly ionospheric index, IGNS, is presented to improve the representation of the solar cycle variation of the ionospheric F2 peak plasma frequency, foF2. IGNS is calculated using a methodology similar to the construction of the "global effective sunspot number", IG, given by Liu et al. (1983) but selects ionosonde observations based on hemispheres. We incorporated the updated index into the International Reference Ionosphere (IRI) model and compared the foF2 model predictions with global ionospheric observations. We also investigated the influence of the underlying foF2 model on the IG index. IRI has two options for foF2 specification, the CCIR-66 and URSI-88 foF2 models. For the first time, we have calculated IG using URSI-88 and assessed the impact on model predictions. Through a retrospective model-data comparison, results show that the inclusion of the new monthly IGNS index in place of the current 12-month smoothed IG index reduce the foF2 model prediction errors by nearly a factor of two. These results apply to both day-time and nightime predictions. This is due to an overall improved prediction of foF2 seasonal and solar cycle variations in the different hemispheres.
de Ory, Fernando; Sanz, Juan Carlos; Echevarría, Juan Emilio; Mosquera, María del Mar; Guisasola, María Eulalia
2004-01-01
The comparison of serological methods used by the laboratories participating in the Network for the Elimination of Measles to diagnose measles virus infection as well as differential diagnosis with other exanthematic diseases are compared. One panel of 20 serum samples including measles (12), rubella (4), parvovirus B19 (2) and dengue (2) infections was established. All cases were diagnosed by detection of specific IgM. The panel was sent to the laboratories of the Network. The results were compared with those obtained at the reference laboratory. Regarding measles, IgM response from 20 laboratories (19 by ELISA and 1 by indirect immunofluorescence) was obtained, with an agreement of 91.5%. Related to rubella IgM, replay from 6 laboratories, using ELISA, was received, with an agreement of 98.7%. With respect to parvovirus B19 IgM, response from 10 laboratories (8 by ELISA and 2 by indirect immunofluorescence) was obtained, with an agreement of 94.6%. Results about dengue virus were not reported by any laboratory. Some laboratories from the network should review the methods used for the diagnosis of measles and other exanthematic diseases. The results reassert the need for a reference laboratory to support confirmation of the results.
Burns, Jennifer B.; Riley, Christopher B.; Shaw, R. Anthony; McClure, J. Trenton
2017-01-01
The objective of this study was to develop and compare the performance of laboratory grade and portable attenuated total reflectance infrared (ATR-IR) spectroscopic approaches in combination with partial least squares regression (PLSR) for the rapid quantification of alpaca serum IgG concentration, and the identification of low IgG (<1000 mg/dL), which is consistent with the diagnosis of failure of transfer of passive immunity (FTPI) in neonates. Serum samples (n = 175) collected from privately owned, healthy alpacas were tested by the reference method of radial immunodiffusion (RID) assay, and laboratory grade and portable ATR-IR spectrometers. Various pre-processing strategies were applied to the ATR-IR spectra that were linked to corresponding RID-IgG concentrations, and then randomly split into two sets: calibration (training) and test sets. PLSR was applied to the calibration set and calibration models were developed, and the test set was used to assess the accuracy of the analytical method. For the test set, the Pearson correlation coefficients between the IgG measured by RID and predicted by both laboratory grade and portable ATR-IR spectrometers was 0.91. The average differences between reference serum IgG concentrations and the two IR-based methods were 120.5 mg/dL and 71 mg/dL for the laboratory and portable ATR-IR-based assays, respectively. Adopting an IgG concentration <1000 mg/dL as the cut-point for FTPI cases, the sensitivity, specificity, and accuracy for identifying serum samples below this cut point by laboratory ATR-IR assay were 86, 100 and 98%, respectively (within the entire data set). Corresponding values for the portable ATR-IR assay were 95, 99 and 99%, respectively. These results suggest that the two different ATR-IR assays performed similarly for rapid qualitative evaluation of alpaca serum IgG and for diagnosis of IgG <1000 mg/dL, the portable ATR-IR spectrometer performed slightly better, and provides more flexibility for potential application in the field. PMID:28651006
Elsohaby, Ibrahim; Burns, Jennifer B; Riley, Christopher B; Shaw, R Anthony; McClure, J Trenton
2017-01-01
The objective of this study was to develop and compare the performance of laboratory grade and portable attenuated total reflectance infrared (ATR-IR) spectroscopic approaches in combination with partial least squares regression (PLSR) for the rapid quantification of alpaca serum IgG concentration, and the identification of low IgG (<1000 mg/dL), which is consistent with the diagnosis of failure of transfer of passive immunity (FTPI) in neonates. Serum samples (n = 175) collected from privately owned, healthy alpacas were tested by the reference method of radial immunodiffusion (RID) assay, and laboratory grade and portable ATR-IR spectrometers. Various pre-processing strategies were applied to the ATR-IR spectra that were linked to corresponding RID-IgG concentrations, and then randomly split into two sets: calibration (training) and test sets. PLSR was applied to the calibration set and calibration models were developed, and the test set was used to assess the accuracy of the analytical method. For the test set, the Pearson correlation coefficients between the IgG measured by RID and predicted by both laboratory grade and portable ATR-IR spectrometers was 0.91. The average differences between reference serum IgG concentrations and the two IR-based methods were 120.5 mg/dL and 71 mg/dL for the laboratory and portable ATR-IR-based assays, respectively. Adopting an IgG concentration <1000 mg/dL as the cut-point for FTPI cases, the sensitivity, specificity, and accuracy for identifying serum samples below this cut point by laboratory ATR-IR assay were 86, 100 and 98%, respectively (within the entire data set). Corresponding values for the portable ATR-IR assay were 95, 99 and 99%, respectively. These results suggest that the two different ATR-IR assays performed similarly for rapid qualitative evaluation of alpaca serum IgG and for diagnosis of IgG <1000 mg/dL, the portable ATR-IR spectrometer performed slightly better, and provides more flexibility for potential application in the field.
Graham, D A; Mawhinney, K A; German, A; Foster, J C; Adair, B M; Merza, M
1999-03-01
Isotype- and subclass-specific indirect enzyme-linked immunosorbent assays were developed to detect parainfluenza-3 virus-specific IgG1, IgG2, IgM, and IgA responses. Sera were treated with protein G-agarose prior to testing for specific IgM and IgA to eliminate the possibility of false-positive results due to IgM-rheumatoid factor and to remove interisotypic competition due to specific IgG. IgM and IgA absorbance values were expressed as a percentage of the absorbance values of positive reference sera included on each plate (S/P%), and respective positive/negative threshold values of 15.0% and 28.0% were determined. The mean interval between experimental infection of 3 calves and initial detection of specific IgG1 and IgG2 responses was 8.0 and 9.3 days respectively, rising rapidly to an initial plateau 13.7 and 11.0 days postinfection (dpi). Reinfection of these calves at 30 dpi resulted in further rapid increases, with higher plateau values reached 13.0 (IgG1) and 13.7 (IgG2) days later. The mean interval between infection and the first positive IgM and IgA responses was 6.7 and 12.3 days, respectively. IgM S/P% values peaked at 13.0 dpi, with all 3 calves showing a secondary anamnestic response to reinfection, peaking 4.7 days later. The IgA response to initial infection was weak, with only 2 calves showing an obvious peak response at 15.0 dpi. A strong anamnestic IgA response to reinfection occurred in 2 calves, with a peak response 9.5 days later. Apparent biphasic and triphasic IgM and IgA responses were evident in some calves. Acute and convalescent serum samples from 80 calves involved in 17 outbreaks of respiratory disease were tested for specific IgM and IgA. Positive IgM results were detected in 15 outbreaks, with 71 sera from 44 calves testing positive. Although IgA-positive results were detected in the same 15 outbreaks, only 42 sera from 31 calves were positive. In a previous study, seroconversion was detected in 21 of these calves from 10 outbreaks. Thus the diagnostic potential of the assays was in the order IgM > IgA > seroconversion. The correlations between IgM and IgA, IgM and seroconversion, and IgA and seroconversion results for each calf were 73.8%, 58.8% and 62.5%, respectively.
Rettig, Trisha A; Ward, Claire; Pecaut, Michael J; Chapes, Stephen K
2017-07-01
Spaceflight is known to affect immune cell populations. In particular, splenic B cell numbers decrease during spaceflight and in ground-based physiological models. Although antibody isotype changes have been assessed during and after space flight, an extensive characterization of the impact of spaceflight on antibody composition has not been conducted in mice. Next Generation Sequencing and bioinformatic tools are now available to assess antibody repertoires. We can now identify immunoglobulin gene- segment usage, junctional regions, and modifications that contribute to specificity and diversity. Due to limitations on the International Space Station, alternate sample collection and storage methods must be employed. Our group compared Illumina MiSeq sequencing data from multiple sample preparation methods in normal C57Bl/6J mice to validate that sample preparation and storage would not bias the outcome of antibody repertoire characterization. In this report, we also compared sequencing techniques and a bioinformatic workflow on the data output when we assessed the IgH and Igκ variable gene usage. This included assessments of our bioinformatic workflow on Illumina HiSeq and MiSeq datasets and is specifically designed to reduce bias, capture the most information from Ig sequences, and produce a data set that provides other data mining options. We validated our workflow by comparing our normal mouse MiSeq data to existing murine antibody repertoire studies validating it for future antibody repertoire studies.
Palma, Marco; de la Roja, Nuria; Montón, Mercedes; Sastre, Patricia; Ramírez, Susana; Barreiro, Belén; Venteo, Angel; Rueda, Paloma
2016-05-01
A duplex rapid assay for detection of serum antibodies to canine parvovirus (CPV) was developed. Canine immunoglobulin (Ig)M or IgG were captured in immunotubes with anti-canine IgM or IgG and detected with parvovirus VP2 recombinant protein followed by an anti-VP2 monoclonal antibody. The assay was tested using a collection of sera from dogs that were vaccinated against CPV on arrival at an animal shelter in Madrid, Spain. Results were compared with those of 2 commercial enzyme-linked immunosorbent assays (ELISAs) considered as reference techniques. A high correlation was found between the duplex rapid assay and the ELISAs, presenting an accuracy of 98% and 100% for IgG and IgM, respectively. According to the IgG and IgM levels at days 0-3 postvaccination, the samples were divided into 2 groups. One group of dogs showed high IgG and low IgM values at the first sampling post-vaccination and during the following 14 days, indicating that they had previously been in contact with the virus, either by vaccination or infection before arrival at the animal shelter. A second group of dogs appeared to be unvaccinated or uninfected before arrival at the animal shelter because they had negative IgM and IgG values soon after vaccination. These animals responded to vaccination, as demonstrated by seroconversion of both isotypes of immunoglobulins. The developed assay appears to be useful in determining the unknown immune status of dogs to CPV, especially in kennels and shelters where the rate of infection by CPV is relatively high. © 2016 The Author(s).
IgM antiavian antibodies in sera from patients with pigeon breeder's disease.
Martínez-Cordero, E; Aguilar León, D E; Retana, V N
2000-01-01
The authors' objective was to study the presence of IgM antiavian antibodies in sera from patients with pigeon breeder's disease. We studied 93 patients with interstitial lung disease admitted for the assessment of pigeon breeder's disease. Eighty sera from healthy donors with no history of bird contact and 47 asymptomatic pigeon breeders were included as controls. The presence of IgM, IgG, and IgA antiavian antibodies was detected by ELISA and Western blot using avian-pooled serum antigen. Fifty-three patients were classified as having definite pigeon breeder's disease, whereas 40 did not fulfill these diagnostic criteria. The levels of IgM antiavian-antibodies in pigeon breeder's disease by ELISA exceeded both the values of healthy subjects with no history of avian contact (P = 2.5 x 10(-8)) and the results of asymptomatic breeders (P = 0. 03). Positive IgA antiavian antibodies were the most frequent abnormalities in pigeon breeder's disease showing values over the reference levels of control groups that reach significant statistical differences. Both precipitin-positive and -negative samples demonstrated IgM reactivity. IgM antiavian antibodies were confirmed by Western blot. A relationship of IgM positive tests with a recent history of avian antigen exposure and acute disease was found. Additionally, the positive IgM group included patients having subacute and chronic lung disease. Antiavian antibodies have previously been considered of minor significance in hypersensitivity pneumonitis; nevertheless, recent studies support their use in clinical diagnosis. Although no specific laboratory tests can confirm the diagnosis in pigeon breeder's disease, IgM antiavian antibodies may be useful for detecting recent antigen exposure and the acute stage of the disease. Copyright 2000 Wiley-Liss, Inc.
NASA Astrophysics Data System (ADS)
Nicolas, J.; Nocquet, J.; van Camp, M.; Coulot, D.
2003-12-01
Time-dependent displacements of stations usually have magnitude close to the accuracy of each individual technique, and it still remains difficult to separate the true geophysical motion from possible artifacts inherent to each space geodetic technique. The Observatoire de la C“te d'Azur (OCA), located at Grasse, France benefits from the collocation of several geodetic instruments and techniques (3 laser ranging stations, and a permanent GPS) what allows us to do a direct comparison of the time series. Moreover, absolute gravimetry measurement campaigns have also been regularly performed since 1997, first by the "Ecole et Observatoire des Sciences de la Terre (EOST) of Strasbourg, France, and more recently by the Royal Observatory of Belgium. This study presents a comparison between the positioning time series of the vertical component derived from the SLR and GPS analysis with the gravimetric results from 1997 to 2003. The laser station coordinates are based on a LAGEOS -1 and -2 combined solution using reference 10-day arc orbits, the ITRF2000 reference frame, and the IERS96 conventions. Different GPS weekly global solutions provided from several IGS are combined and compared to the SLR results. The absolute gravimetry measurements are converted into vertical displacements with a classical gradient. The laser time series indicate a strong annual signal at the level of about 3-4 cm peak to peak amplitude on the vertical component. Absolute gravimetry data agrees with the SLR results. GPS positioning solutions also indicate a significant annual term, but with a magnitude of only 50% of the one shown by the SLR solution and by the gravimetry measurements. Similar annual terms are also observed on other SLR sites we processed, but usually with! lower and various amplitudes. These annual signals are also compared to vertical positioning variations corresponding to an atmospheric loading model. We present the level of agreement between the different techniques and we discuss possible explanations for the discrepancy noted between the signals. At last, we expose explanations for the large annual term at Grasse: These annual variations could be partly due to an hydrological loading effect on the karstic massif on which the observatory is located.
Gregorek, H; Chrzanowska, K H; Michałkiewicz, J; Syczewska, M; Madaliński, K
2002-01-01
During an 8-year period of observation, defects of immune responses were characterized and monitored in 40 of 50 Polish children with Nijmegen breakage syndrome referred to the Children's Memorial Health Institute in Warsaw. The following parameters were determined at diagnosis: (1) concentrations of serum IgM, IgG, IgA; (2) concentrations of IgG subclasses; and (3) lymphocyte subpopulations. In addition, naturally acquired specific antibodies against Streptococcus pneumoniae were determined in 20 patients with a history of recurrent respiratory infections. During follow-up, total serum immunoglobulins and IgG subclasses were monitored systematically in 17 patients who did not receive immunomodulatory therapy. Moreover, anti-HBs antibody response was measured after vaccination of 20 children against HBV. We found that the immune deficiency in NBS is profound, highly variable, with a tendency to progress over time. Systematic monitoring of the humoral response, despite good clinical condition, is essential for early medical intervention. PMID:12390322
Coastal Vertical Land motion in the German Bight
NASA Astrophysics Data System (ADS)
Becker, Matthias; Fenoglio, Luciana; Reckeweg, Florian
2017-04-01
In the framework of the ESA Sea Level Climate Change Initiative (CCI) we analyse a set of GNSS equipped tide gauges at the German Bight. Main goals are the determination of tropospheric zenith delay corrections for altimetric observations, precise coordinates in ITRF2008 and vertical land motion (VLM) rates of the tide gauge stations. These are to be used for georeferencing the tide gauges and the correction of tide gauge observations for VLM. The set of stations includes 38 GNSS stations. 19 stations are in the German Bight, where 15 of them belong to the Bundesanstalt für Gewässerkunde, 3 to EUREF and 1 to GREF. These stations are collocated with tide gauges (TGs). The other 19 GNSS stations in the network belong to EUREF, IGS and GREF. We analyse data in the time span from 2008 till the end of 2016 with the Bernese PPP processing approach. Data are partly rather noisy and disturbed by offsets and data gaps at the coastal TG sites. Special effort is therefore put into a proper estimation of the VLM. We use FODITS (Ostini2012), HECTOR (Bos et al, 2013), CATS (Williams, 2003) and the MIDAS approach of Blewitt (2016) to robustly derive rates and realistic error estimates. The results are compared to those published by the European Permanent Network (EPN), ITRF and the Système d'Observation du Niveau des Eaux Littorales (SONEL) for common stations. Vertical motion is small in general, at the -1 to -2 mm/yr level for most coastal stations. A comparison of the standard deviations of the velocity differences to EPN with the mean values of the estimated velocity standard deviations for our solution shows a very good agreement of the estimated velocities and their standard deviations with the reference solution from EPN. In the comparison with results by SONEL the standard deviation of the differences is slightly higher. The discrepancies may arise from differences in the time span analyzed and gaps, offsets and data preprocessing. The combined estimation of functional and stochastic parameters is rather sensitive to the characteristics of the time series and thus the estimated velocity also depends on the applied stochastic model and on the selected parameters. The GPS vertical land motion rates are finally compared to the difference between sea level rates measured by co-located altimetry and by tide gauge station data, which gives another estimation of VLM.
Detection of Toxoplasma gondii in Diabetic Patients Using the Nested PCR Assay via RE and B1 Genes.
Mousavi, Mohammad; Saravani, Ramin; Jafari Modrek, Mohammad; Shahrakipour, Mahnaz; Sekandarpour, Sina
2016-02-01
Toxoplasma gondii is an obligate intracellular protozoan parasite that exists worldwide. Various techniques have been developed for T. gondii detection. The aim of this study was the detection of T. gondii in diabetic patients with RE and B1 genes and the comparison of these two genes for diagnosis using the nested-PCR assay method. DNA samples from 205 diabetic patients who had been referred to the diabetes center of Ali Asghar hospital in Zahedan, Iran, were collected and analyzed using the nested-PCR assay method. Toxoplasma antibody data gathered using the enzyme-linked immunosorbent assay (ELISA) method from a previous study was used to group patients. The data were analyzed using SPSS 18. The chi-square test was used for comparison. Of the diabetic patients selected, the following results were obtained: 53 (IgG+, IgM+); 20 (IgG-, IgM+); 72 (IgG+, IgM-); and 60 (IgG-, IgM-). The nested-PCR detected the following: in the acute group, 21/53 (39.63%), 30/53 (56.60%) (IgM+, IgG+); in the chronic group, 40/72 (55.56%), 51/72 (70.83%), (IgG+, IgM-); in the false positive group, 18/20 (90%), 17/20 (85%) (IgM+, IgG-); and sero-negative samples of 38/60 (63.33%) and 60/ 41 (77.35%) for RE and B1 genes, respectively. The prevalence of toxoplasmosis showed positive in patients with diabetes in the B1 gene 139 (67.8%) and RE gene 117 (57.1%). Our study demonstrated that the B1 gene, more so than the RE gene, showed positive samples and can be used to detect toxoplasmosis, although the B1 gene, in comparison to the RE gene, did not show any superiority of molecular diagnosing capability. Results also showed that toxoplasma molecular detection methods can be used instead of routine serological detection methods in a clinical laboratory testing.
NASA Astrophysics Data System (ADS)
Montenbruck, Oliver; Steigenberger, Peter; Prange, Lars; Deng, Zhiguo; Zhao, Qile; Perosanz, Felix; Romero, Ignacio; Noll, Carey; Stürze, Andrea; Weber, Georg; Schmid, Ralf; MacLeod, Ken; Schaer, Stefan
2017-04-01
Over the past five years, the International GNSS Service (IGS) has made continuous efforts to extend its service from GPS and GLONASS to the variety of newly established global and regional navigation satellite systems. This report summarizes the achievements and progress made in this period by the IGS Multi-GNSS Experiment (MGEX). The status and tracking capabilities of the IGS monitoring station network are presented and the multi-GNSS products derived from this resource are discussed. The achieved performance is assessed and related to the current level of space segment and user equipment characterization. While the performance of orbit and clock products for BeiDou, Galileo, and QZSS still lags behind the legacy GPS and GLONASS products, continued progress has been made since launch of the MGEX project and already enables use of the new constellations for precise point positioning, atmospheric research and other applications. Directions for further research are identified to fully integrate the new constellations into routine GNSS processing. Furthermore, the active support of GNSS providers is encouraged to assist the scientific community in the generation of fully competitive products for the new constellations.
A closer look at the concept of regional clocks for Precise Point Positioning
NASA Astrophysics Data System (ADS)
Weber, Robert; Karabatic, Ana; Thaler, Gottfried; Abart, Christoph; Huber, Katrin
2010-05-01
Under the precondition of at least two successfully tracked signals at different carrier frequencies we may obtain their ionosphere free linear combination. By introducing approximate values for geometric effects like orbits and tropospheric delay as well as an initial bias parameter N per individual satellite we can solve for the satellite clock with respect to the receiver clock. Noting, that residual effects like orbit errors, remaining tropospheric delays and a residual bias parameter map into these parameters, this procedure leaves us with a kind of virtual clock differences. These clocks cover regional effects and are therefore clearly correlated with clocks at nearby station. Therefore we call these clock differences, which are clearly different from clock solutions provided for instance by IGS, the "regional clocks". When introducing the regional clocks obtained from real-time data of a GNSS reference station network we are able to process the coordinates of a nearby isolated station via a PPP .In terms of PPP-convergence time which will be reduced down to 30 minutes or less, this procedure is clearly favorable. The accuracy is quite comparable with state of the art PPP procedures. Nevertheless, this approach cannot compete in fixing times with double-difference approaches but the correlation holds over hundreds of kilometers distance to our master station and the clock differences can easily by obtained, even in real-time. This presentation provides preliminary results of the project RA-PPP. RA-PPP is a research project financed by the Federal Ministry for Transport, Innovation and Technology, managed by the Austrian Research Promotion Agency (FFG) in the course of the 6th call of the Austrian Space Application Program (ASAP). RA-PPP stands for Rapid Precise Point Positioning, which denotes the wish for faster and more accurate algorithms for PPP. The concept of regional clocks which will be demonstrated in detail in this presentation is one out of 4 concepts to be evaluated in this project.
Minicomputer front end. [Modcomp II/CP as buffer between CDC 6600 and PDP-9 at graphics stations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hudson, J.A.
1976-01-01
Sandia Labs developed an Interactive Graphics System (SIGS) that was established on a CDC 6600 using a communication scheme based on the Control Data Corporation product IGS. As implemented at Sandia, the graphics station consists primarily of a PDP-9 with a Vector General display. A system is being developed which uses a minicomputer (Modcomp II/CP) as the buffer machine for the graphics stations. The original SIGS required a dedicated peripheral processor (PP) on the CDC 6600 to handle the communication with the stations; however, with the Modcomp handling the actual communication protocol, the PP is only assigned as needed tomore » handle data transfer within the CDC 6600 portion of SIGS. The new system will thus support additional graphics stations with less impact on the CDC 6600. This paper discusses the design philosophy of the system, and the hardware and software used to implement it. 1 figure.« less
Space Station reference configuration description
NASA Technical Reports Server (NTRS)
1984-01-01
The data generated by the Space Station Program Skunk Works over a period of 4 months which supports the definition of a Space Station reference configuration is documented. The data were generated to meet these objectives: (1) provide a focal point for the definition and assessment of program requirements; (2) establish a basis for estimating program cost; and (3) define a reference configuration in sufficient detail to allow its inclusion in the definition phase Request for Proposal (RFP).
Design and operation of a Loran-C time reference station
NASA Technical Reports Server (NTRS)
Putkovich, K.
1974-01-01
Some of the practical questions that arise when one decides to use Loran-C in a time reference system are explored. An extensive effort is made to provide basic, practical information on establishing and operating a reference station. Four areas were covered: (1) the design, configuration and operational concepts which should be considered prior to establishing and operating a reference station using Loran-C, (2) the options and tradeoffs available regarding capabilities, cost, size, versatility, ease of operation, etc., that are available to the designer, (3) what measurements are made, how they are made and what they mean, and (4) the experience the U.S. Naval Observatory Time Service Division has had in the design and operation of such stations.
Diagnostic Utility of Total IgE in Foods, Inhalant, and Multiple Allergies in Saudi Arabia.
Al-Mughales, Jamil A
2016-01-01
Objective. To assess the diagnostic significance of total IgE in foods, inhalant, and multiple allergies. Methods. Retrospective review of the laboratory records of patients who presented with clinical suspicion of food or inhalant allergy between January 2013 and December 2014. Total IgE level was defined as positive for a value >195 kU/L; and diagnosis was confirmed by the detection of specific IgE (golden standard) for at least one food or inhalant allergen and at least two allergens in multiple allergies. Results. A total of 1893 (male ratio = 0.68, mean age = 39.0 ± 19.2 years) patients were included. Total IgE had comparable sensitivity (55.8% versus 59.6%) and specificity (83.9% versus 84.4%) in food versus inhalant allergy, respectively, but a superior PPV in inhalant allergy (79.1% versus 54.4%). ROC curve analysis showed a better diagnostic value in inhalant allergies (AUC = 0.817 (95% CI = 0.796-0.837) versus 0.770 (95% CI = 0.707-0.833)). In multiple allergies, total IgE had a relatively good sensitivity (78.6%), while negative IgE testing (<195 kU/L) predicted the absence of multiple allergies with 91.5% certitude. Conclusion. Total IgE assay is not efficient as a diagnostic test for foods, inhalant, or multiple allergies. The best strategy should refer to specific IgE testing guided by a comprehensive atopic history.
Diagnostic Utility of Total IgE in Foods, Inhalant, and Multiple Allergies in Saudi Arabia
Al-Mughales, Jamil A.
2016-01-01
Objective. To assess the diagnostic significance of total IgE in foods, inhalant, and multiple allergies. Methods. Retrospective review of the laboratory records of patients who presented with clinical suspicion of food or inhalant allergy between January 2013 and December 2014. Total IgE level was defined as positive for a value >195 kU/L; and diagnosis was confirmed by the detection of specific IgE (golden standard) for at least one food or inhalant allergen and at least two allergens in multiple allergies. Results. A total of 1893 (male ratio = 0.68, mean age = 39.0 ± 19.2 years) patients were included. Total IgE had comparable sensitivity (55.8% versus 59.6%) and specificity (83.9% versus 84.4%) in food versus inhalant allergy, respectively, but a superior PPV in inhalant allergy (79.1% versus 54.4%). ROC curve analysis showed a better diagnostic value in inhalant allergies (AUC = 0.817 (95% CI = 0.796–0.837) versus 0.770 (95% CI = 0.707–0.833)). In multiple allergies, total IgE had a relatively good sensitivity (78.6%), while negative IgE testing (<195 kU/L) predicted the absence of multiple allergies with 91.5% certitude. Conclusion. Total IgE assay is not efficient as a diagnostic test for foods, inhalant, or multiple allergies. The best strategy should refer to specific IgE testing guided by a comprehensive atopic history. PMID:27314052
IgG4-Related Kidney Disease: Report of a Case Presenting as a Renal Mass
Topazio, Luca; Gaziev, Gabriele; Iacovelli, Valerio; Bove, Pierluigi; Mauriello, Alessandro; Finazzi Agrò, Enrico
2017-01-01
IgG4-related disease (IgG4-RD) is a nosological entity defined as a chronic immune-mediated fibro-inflammatory condition characterized by a tendency to form tumefactive, tissue-destructive lesions or by organ failure. Urologic involvement in IgG4-RD has been described in some short series of patients and in isolated case reports, most often involving the kidneys in so-called IgG4-related kidney disease (IgG4-RKD). The disease can occasionally mimic malignancies and is at risk of being misdiagnosed due to its rarity. We report the case of a 56-year-old man presenting with a right renal mass suspected of being malignant. Laboratory tests showed normal creatinine levels, a high erythrocyte sedimentation rate, and high levels of C-reactive protein and microalbuminuria. The patient underwent radical right nephroureterectomy and histopathologic examination revealed features proving IgG4-RKD. He was therefore referred to immunologists. Typical clinical presentation of IgG4-RKD includes altered renal function with inconstant or no radiologic findings. Conversely, in the case we presented, a single nodule was detected upon imaging evaluation, thus mimicking malignancy. This raises the issue of a proper differential diagnosis. A multidisciplinary approach can be useful, although in clinical practice the selection of patients suspected of having IgG4-RKD is critical in the cases presenting with a renal mass that mimics malignancy. PMID:28912998
Effect of Therapeutic Plasma Exchange on Immunoglobulins in Myasthenia Gravis
Guptill, Jeffrey T.; Juel, Vern C.; Massey, Janice M.; Anderson, Amanda C.; Chopra, Manisha; Yi, John S.; Esfandiari, Ehsanollah; Buchanan, Tim; Smith, Bryan; Atherfold, Paul; Jones, Emma; Howard, James F.
2017-01-01
An integrated understanding of therapeutic plasma exchange (TPE) effects on immunoglobulins, autoantibodies, and natural or acquired (vaccine) protective antibodies in patients with autoimmune myasthenia gravis (MG) is lacking. Prior studies measured TPE effects in healthy volunteers or heterogeneous autoimmune diseases populations. We prospectively profiled plasma IgA, IgM, IgG, IgG subclasses (IgG1-4), acetylcholine receptor autoantibodies (AChR+), and protective antibodies in patients with AChR+ MG receiving TPE for an exacerbation. TPE was performed according to institutional practice and patients were profiled for up to 12 weeks. Ten patients were enrolled (median age=72.9 years; baseline MG-Composite=21; median TPE treatments=6 during their first course) and all improved. The maximum decrease in all immunoglobulins, including AChR autoantibodies, was achieved on the final day of the first TPE course (approximately 60–70% reduction). Three weeks post-TPE mean AChR autoantibody, total IgG, IgG1 and IgG2 titers were below the reference range and had not recovered to within 20% of baseline, whereas other measured immunoglobulins approached baseline values. We did not generally observe an “overshoot” of immunoglobulins above pre-TPE levels or accelerated recovery of pathologic AChR autoantibodies. Protective antibody profiles showed similar patterns as other IgGs and were detectable at levels associated with protection from infection. A slow return to baseline for IgGs (except IgG3) was observed, and we did not observe any obvious effect of concomitant medications on this recovery. Collectively, these findings enhance our understanding of the immunological effects of TPE and further supports the concept of rapid immunoglobulin depletion for the treatment of patients with MG. PMID:27684107
Effect of therapeutic plasma exchange on immunoglobulins in myasthenia gravis.
Guptill, Jeffrey T; Juel, Vern C; Massey, Janice M; Anderson, Amanda C; Chopra, Manisha; Yi, John S; Esfandiari, Ehsanollah; Buchanan, Tim; Smith, Bryan; Atherfold, Paul; Jones, Emma; Howard, James F
2016-11-01
An integrated understanding of therapeutic plasma exchange (TPE) effects on immunoglobulins, autoantibodies, and natural or acquired (vaccine) protective antibodies in patients with autoimmune myasthenia gravis (MG) is lacking. Prior studies measured TPE effects in healthy volunteers or heterogeneous autoimmune disease populations. We prospectively profiled plasma IgA, IgM, IgG, IgG subclasses (IgG1-4), acetylcholine receptor autoantibodies (AChR+), and protective antibodies in patients with AChR + MG receiving TPE for an exacerbation. TPE was performed according to institutional practice and patients were profiled for up to 12 weeks. Ten patients were enrolled (median age = 72.9 years; baseline MG-Composite = 21; median TPE treatments = 6 during their first course) and all improved. The maximum decrease in all immunoglobulins, including AChR autoantibodies, was achieved on the final day of the first TPE course (∼60-70% reduction). Three weeks post-TPE, mean AChR autoantibody, total IgG, IgG1, and IgG2 titers were below the reference range and had not recovered within 20% of baseline, whereas other measured immunoglobulins approached baseline values. We did not generally observe an "overshoot" of immunoglobulins above pre-TPE levels or accelerated recovery of pathologic AChR autoantibodies. Protective antibody profiles showed similar patterns as other IgGs and were detectable at levels associated with protection from infection. A slow return to baseline for IgGs (except IgG3) was observed, and we did not observe any obvious effect of concomitant medications on this recovery. Collectively, these findings enhance our understanding of the immunological effects of TPE and further support the concept of rapid immunoglobulin depletion for the treatment of patients with MG.
Office-Based Point of Care Testing (IgA/IgG-Deamidated Gliadin Peptide) for Celiac Disease.
Lau, Michelle S; Mooney, Peter D; White, William L; Rees, Michael A; Wong, Simon H; Hadjivassiliou, Marios; Green, Peter H R; Lebwohl, Benjamin; Sanders, David S
2018-06-19
Celiac disease (CD) is common yet under-detected. A point of care test (POCT) may improve CD detection. We aimed to assess the diagnostic performance of an IgA/IgG-deamidated gliadin peptide (DGP)-based POCT for CD detection, patient acceptability, and inter-observer variability of the POCT results. From 2013-2017, we prospectively recruited patients referred to secondary care with gastrointestinal symptoms, anemia and/or weight loss (group 1); and patients with self-reported gluten sensitivity with unknown CD status (group 2). All patients had concurrent POCT, IgA-tissue transglutaminase (IgA-TTG), IgA-endomysial antibodies (IgA-EMA), total IgA levels, and duodenal biopsies. Five hundred patients completed acceptability questionnaires, and inter-observer variability of the POCT results was compared among five clinical staff for 400 cases. Group 1: 1000 patients, 58.5% female, age 16-91, median age 57. Forty-one patients (4.1%) were diagnosed with CD. The sensitivities of the POCT, IgA-TTG, and IgA-EMA were 82.9, 78.1, and 70.7%; the specificities were 85.4, 96.3, and 99.8%. Group 2: 61 patients, 83% female; age 17-73, median age 35. The POCT had 100% sensitivity and negative predictive value in detecting CD in group 2. Most patients preferred the POCT to venepuncture (90.4% vs. 2.8%). There was good inter-observer agreement on the POCT results with a Fleiss Kappa coefficient of 0.895. The POCT had comparable sensitivities to serology, and correctly identified all CD cases in a gluten sensitive cohort. However, its low specificity may increase unnecessary investigations. Despite its advantage of convenience and rapid results, it may not add significant value to case finding in an office-based setting.
Related Mechanisms of Antibody Somatic Hypermutation and Class Switch Recombination
HWANG, JOYCE K.; ALT, FREDERICK W.; YEAP, LENG-SIEW
2015-01-01
The primary antibody repertoire is generated by mechanisms involving the assembly of the exons that encode the antigen-binding variable regions of immunoglobulin heavy (IgH) and light (IgL) chains during the early development of B lymphocytes. After antigen-dependent activation, mature B lymphocytes can further alter their IgH and IgL variable region exons by the process of somatic hypermutation (SHM), which allows the selection of B cells in which SHMs resulted in the production of antibodies with increased antigen affinity. In addition, during antigen-dependent activation, B cells can also change the constant region of their IgH chain through a DNA double-strand-break (DSB) dependent process referred to as IgH class switch recombination (CSR), which generates B cell progeny that produce antibodies with different IgH constant region effector functions that are best suited for a elimination of a particular pathogen or in a particular setting. Both the mutations that underlie SHM and the DSBs that underlie CSR are initiated in target genes by activation-induced cytidine deaminase (AID). This review describes in depth the processes of SHM and CSR with a focus on mechanisms that direct AID cytidine deamination in activated B cells and mechanisms that promote the differential outcomes of such cytidine deamination. PMID:26104555
Unproven techniques in allergy diagnosis.
Wüthrich, B
2005-01-01
Mainstream allergy diagnosis and treatment is based on classical allergy testing which involves well-validated diagnostic methods and proven methods of treatment. By contrast, a number of unproven tests have been proposed for evaluating allergic patients including cytotoxic food testing, ALCAT test, bioresonance, electrodermal testing (electroacupuncture), reflexology, applied kinesiology a.o. There is little or no scientific rationale for these methods. Results are not reproducible when subject to rigorous testing and do not correlate with clinical evidence of allergy. Although some papers suggest a possible pathogenetic role of IgG, IgG4 antibody, no correlation was found between the outcome of DBPCFC and the levels of either food-specific IgG or IgG4, nor was any difference seen between patients and controls. The levels of these and other food-specific immunoglobulins of non-IgE isotype reflect the intake of food in the individual and may thus be a normal and harmless finding. The so-called "Food Allergy Profile" with simultaneous IgE and IgG determination against more than 100 foodstuffs is neither economical nor useful for diagnosis. DBPCFC must be the reference standard for food hypersensitivity and any new test must be validated by it. As a result, all these unproven techniques may lead to misleading advice or treatments, and their use is not advised.
Gabriel, Martin; Adomeh, Donatus I.; Ehimuan, Jacqueline; Oyakhilome, Jennifer; Omomoh, Emmanuel O.; Ighodalo, Yemisi; Olokor, Thomas; Bonney, Kofi; Pahlmann, Meike; Emmerich, Petra; Lelke, Michaela; Brunotte, Linda; Ölschläger, Stephan; Thomé-Bolduan, Corinna; Becker-Ziaja, Beate; Busch, Carola; Odia, Ikponmwosa; Ogbaini-Emovon, Ephraim; Okokhere, Peter O.; Okogbenin, Sylvanus A.; Akpede, George O.; Schmitz, Herbert; Asogun, Danny A.
2018-01-01
Background The classical method for detection of Lassa virus-specific antibodies is the immunofluorescence assay (IFA) using virus-infected cells as antigen. However, IFA requires laboratories of biosafety level 4 for assay production and an experienced investigator to interpret the fluorescence signals. Therefore, we aimed to establish and evaluate enzyme-linked immunosorbent assays (ELISA) using recombinant Lassa virus nucleoprotein (NP) as antigen. Methodology/Principal findings The IgM ELISA is based on capturing IgM antibodies using anti-IgM, and the IgG ELISA is based on capturing IgG antibody–antigen complexes using rheumatoid factor or Fc gamma receptor CD32a. Analytical and clinical evaluation was performed with 880 sera from Lassa fever endemic (Nigeria) and non-endemic (Ghana and Germany) areas. Using the IFA as reference method, we observed 91.5–94.3% analytical accuracy of the ELISAs in detecting Lassa virus-specific antibodies. Evaluation of the ELISAs for diagnosis of Lassa fever on admission to hospital in an endemic area revealed a clinical sensitivity for the stand-alone IgM ELISA of 31% (95% CI 25–37) and for combined IgM/IgG detection of 26% (95% CI 21–32) compared to RT-PCR. The specificity of IgM and IgG ELISA was estimated at 96% (95% CI 93–98) and 100% (95% CI 99–100), respectively, in non-Lassa fever patients from non-endemic areas. In patients who seroconverted during follow-up, Lassa virus-specific IgM and IgG developed simultaneously rather than sequentially. Consistent with this finding, isolated IgM reactivity, i.e. IgM in the absence of IgG, had no diagnostic value. Conclusions/Significance The ELISAs are not equivalent to RT-PCR for early diagnosis of Lassa fever; however, they are of value in diagnosing patients at later stage. The IgG ELISA may be useful for epidemiological studies and clinical trials due its high specificity, and the higher throughput rate and easier operation compared to IFA. PMID:29596412
Secretory immunity with special reference to the oral cavity
Brandtzaeg, Per
2013-01-01
The two principal antibody classes present in saliva are secretory IgA (SIgA) and IgG; the former is produced as dimeric IgA by local plasma cells (PCs) in the stroma of salivary glands and is transported through secretory epithelia by the polymeric Ig receptor (pIgR), also named membrane secretory component (SC). Most IgG in saliva is derived from the blood circulation by passive leakage mainly via gingival crevicular epithelium, although some may be locally produced in the gingiva or salivary glands. Gut-associated lymphoid tissue (GALT) and nasopharynx-associated lymphoid tissue (NALT) do not contribute equally to the pool of memory/effector B cells differentiating to mucosal PCs throughout the body. Thus, enteric immunostimulation may not be the best way to activate the production of salivary IgA antibodies although the level of specific SIgA in saliva may still reflect an intestinal immune response after enteric immunization. It remains unknown whether the IgA response in submandibular/sublingual glands is better related to B-cell induction in GALT than the parotid response. Such disparity is suggested by the levels of IgA in submandibular secretions of AIDS patients, paralleling their highly upregulated intestinal IgA system, while the parotid IgA level is decreased. Parotid SIgA could more consistently be linked to immune induction in palatine tonsils/adenoids (human NALT) and cervical lymph nodes, as supported by the homing molecule profile observed after immune induction at these sites. Several other variables influence the levels of antibodies in salivary secretions. These include difficulties with reproducibility and standardization of immunoassays, the impact of flow rate, acute or chronic stress, protein loss during sample handling, and uncontrolled admixture of serum-derived IgG and monomeric IgA. Despite these problems, saliva is an easily accessible biological fluid with interesting scientific and clinical potentials. PMID:23487566
Maple, Peter A C; Beard, Stuart; Parry, Ruth P; Brown, Kevin E
2013-10-01
Human parvovirus 4 (ParV4), a newly described member of the family Parvoviridae, like B19V, has been found in pooled plasma preparations. The extent, and significance, of ParV4 exposure in UK blood donors remain to be determined and reliable detection of ParV4 immunoglobulin (Ig)G, using validated methods, is needed. With ParV4 virus-like particles a ParV4 IgG time-resolved fluorescence immunoassay (TRFIA) was developed. There is no gold standard or reference assay for measuring ParV4 IgG and the utility of the TRFIA was first examined using a panel of sera from people who inject drugs (PWIDS)--a high-prevalence population for ParV4 infection. Western blotting was used to confirm the specificity of TRFIA-reactive sera. Two cohorts of UK blood donor sera comprising 452 sera collected in 1999 and 156 sera collected in 2009 were tested for ParV4 IgG. Additional testing for B19V IgG, hepatitis C virus antibodies (anti-HCV), and ParV4 DNA was also undertaken. The rate of ParV4 IgG seroprevalence in PWIDS was 20.7% and ParV4 IgG was positively associated with the presence of anti-HCV with 68.4% ParV4 IgG-positive sera testing anti-HCV-positive versus 17.1% ParV4 IgG-negative sera. Overall seropositivity for ParV4 IgG, in 608 UK blood donors was 4.76%. The ParV4 IgG seropositivity for sera collected in 1999 was 5.08%, compared to 3.84% for sera collected in 2009. No ParV4 IgG-positive blood donor sera had detectable ParV4 DNA. ParV4 IgG has been found in UK blood donors and this finding needs further investigation. © 2013 American Association of Blood Banks.
Weiss, Michael
2017-06-01
Appropriate model selection is important in fitting oral concentration-time data due to the complex character of the absorption process. When IV reference data are available, the problem is the selection of an empirical input function (absorption model). In the present examples a weighted sum of inverse Gaussian density functions (IG) was found most useful. It is shown that alternative models (gamma and Weibull density) are only valid if the input function is log-concave. Furthermore, it is demonstrated for the first time that the sum of IGs model can be also applied to fit oral data directly (without IV data). In the present examples, a weighted sum of two or three IGs was sufficient. From the parameters of this function, the model-independent measures AUC and mean residence time can be calculated. It turned out that a good fit of the data in the terminal phase is essential to avoid parameter biased estimates. The time course of fractional elimination rate and the concept of log-concavity have proved as useful tools in model selection.
Topo-Iberia GPS network: installation complete
NASA Astrophysics Data System (ADS)
Khazaradze, G.
2009-04-01
As part of the project, titled "Geociencias en Iberia: Estudios integrados de topografía y evolución 4D: Topo-Iberia", we have established a network of 26 continuous GPS stations, covering the Spanish part of the Iberian Peninsula (22 stations) and Morocco (4 stations). A major objective behind the establishment of this array is to monitor millimeter level deformation of the crust due to the collision of African and Eurasian (including Iberian) tectonic plates. More specific goals of the project include the identification of the areas and/or specific seismic faults which exhibit higher deformation rates, which could imply an increased seismic hazard in these specific areas. The network has been designed as two X-shaped transects crossing the peninsula from NE to SW and NW to SE, with relatively coarse distribution of the stations, superimposed with denser coverage in the seismically active areas of the Betics, Pyrenees and Cantabrian chains. The majority of the built monuments consist of 1.5-1.8 m tall concrete pillars of 40 cm in diameter anchored to the bedrock using iron rebars. One station in Huesca was built according the UNAVCO's short drilled braced monument (SDBM) specifications. All the monuments were equipped with the SCIGN leveling mounts to ensure the precise antenna alignment and re-alignment in case of the antenna replacement, as well as, tamper resistance of the monument mark. In places were the snow accumulation was possible the antennas were covered with plastic radomes. The instrumentation used is Trimble NetRS dual-frequency receivers with choke-ring antennas. The communication is mainly via cellular telephone system. As of December 2008, the network installation has been competed and all the stations are fully operational. Here we report the milestones of the installation of the network and, as well as, present the first preliminary results of the analysis of the data. Besides the newly established Topo-Iberia CGPS stations, we have included in our daily analysis the data from the selected IGS and EUREF stations located within the region of our interest. In our analysis we also include data from the regional GPS network in Spain: CATNET in Catalonia, ERVA in Valencia, RAP in Andalucía and several other stations from Rioja, Basque country and Castilla León. The GPS data were analyzed using GAMIT/GLOBK software from MIT employing a network mode, where all the stations (including IGS continuous GPS sites) are analyzed simultaneously, followed by carrier phase ambiguity resolution. The work has been supported by the Spanish Ministry of Science and Innovation project: Topo-Iberia (CSD2006-00041).
Networked differential GPS system
NASA Technical Reports Server (NTRS)
Sheynblat, Leonid (Inventor); Kalafus, Rudolph M. (Inventor); Loomis, Peter V. W. (Inventor); Mueller, K. Tysen (Inventor)
1994-01-01
An embodiment of the present invention relates to a worldwide network of differential GPS reference stations (NDGPS) that continually track the entire GPS satellite constellation and provide interpolations of reference station corrections tailored for particular user locations between the reference stations Each reference station takes real-time ionospheric measurements with codeless cross-correlating dual-frequency carrier GPS receivers and computes real-time orbit ephemerides independently. An absolute pseudorange correction (PRC) is defined for each satellite as a function of a particular user's location. A map of the function is constructed, with iso-PRC contours. The network measures the PRCs at a few points, so-called reference stations and constructs an iso-PRC map for each satellite. Corrections are interpolated for each user's site on a subscription basis. The data bandwidths are kept to a minimum by transmitting information that cannot be obtained directly by the user and by updating information by classes and according to how quickly each class of data goes stale given the realities of the GPS system. Sub-decimeter-level kinematic accuracy over a given area is accomplished by establishing a mini-fiducial network.
Vilor-Tejedor, Natàlia; Cáceres, Alejandro; Pujol, Jesús; Sunyer, Jordi; González, Juan R
2017-12-01
Joint analysis of genetic and neuroimaging data, known as Imaging Genetics (IG), offers an opportunity to deepen our knowledge of the biological mechanisms of neurodevelopmental domains. There has been exponential growth in the literature on IG studies, which challenges the standardization of analysis methods in this field. In this review we give a complete up-to-date account of IG studies on attention deficit hyperactivity disorder (ADHD) and related neurodevelopmental domains, which serves as a reference catalog for researchers working on this neurological disorder. We searched MEDLINE/Pubmed and identified 37 articles on IG of ADHD that met our eligibility criteria. We carefully cataloged these articles according to imaging technique, genes and brain region, and summarized the main results and characteristics of each study. We found that IG studies on ADHD generally focus on dopaminergic genes and the structure of basal ganglia using structural Magnetic Resonance Imaging (MRI). We found little research involving multiple genetic factors and brain regions because of the scarce use of multivariate strategies in data analysis. IG of ADHD and related neurodevelopmental domains is still in its early stages, and a lack of replicated findings is one of the most pressing challenges in the field.
Oshima, Yoichi; Hoshino, Junichi; Suwabe, Tatsuya; Hayami, Noriko; Yamanouchi, Masayuki; Sekine, Akinari; Ueno, Toshiharu; Mizuno, Hiroki; Yabuuchi, Junko; Imafuku, Aya; Kawada, Masahiro; Hiramatsu, Rikako; Hasegawa, Eiko; Sawa, Naoki; Takaichi, Kenmei; Hayashi, Nobukazu; Fujii, Takeshi; Ubara, Yoshifumi
2017-03-01
A 41-year-old man was referred to our hospital for the evaluation of hypergammaglobulinemia (IgG 2898 mg/dL and IgA 587 mg/dL), inflammation (CRP 6.7 mg/dL and serum interleukin-6 (IL-6) 15.1 ng/L), and anemia (Hb 10.9 mg/dL). Castleman's disease (CD) was diagnosed by axillary lymph node biopsy. Five months later, painful purpura (multiple palpable 5 mm lesions) developed on his legs, gradually spreading to the upper limbs, thighs, and trunk, accompanied by arthralgia of the wrists, ankles, and knees. Skin biopsy revealed leukocytoclastic vasculitis with IgA deposits in dermal vessels. Accordingly, IgA vasculitis (Henoch-Schönlein purpura) was diagnosed. Tocilizumab (an anti-IL-6 receptor antibody) was administered intravenously at 8 mg/kg and treatment was repeated at monthly intervals. His purpura and clinical findings specific to CD improved rapidly. CD is well known to cause various skin lesions. The findings in this case indicate that overproduction of IL-6 contributes to IgA vasculitis (Henoch-Schönlein purpura) as well as to the pathogenesis of CD.
Investigation of the TEC Changes in the vicinity of the Earthquake Preparation Zone
NASA Astrophysics Data System (ADS)
Ulukavak, Mustafa; Yalcinkaya, Mualla
2016-04-01
Recently, investigation of the anomalies in the ionosphere before the earthquake has taken too much attention. The Total Electron Content (TEC) data has been used to monitor the changes in the ionosphere. Hence, researchers use the TEC changes before the strong earthquakes to monitor the anomalies in the ionosphere. In this study, the GPS-TEC variations, obtained from the GNSS stations in the vicinity of the earthquake preparation zone, was investigated. Nidra earthquake (M6.5), which was occurred on the north-west of Greece on November 17th, 2015 (38.755°N, 20.552°E), was selected for this study. First, the equation proposed by Dobrovolsky et al. (1979) was used to calculate the radius of the earthquake preparation zone. International GNSS Service (IGS) stations in the region were classified with respect to the radius of the earthquake preparation zone. The observation data of each station was obtained from the Crustal Dynamics Data and Information System (CDDIS) archive to estimate GPS-TEC variations between 16 October 2015 and 16 December 2015. Global Ionosphere Maps (GIM) products, obtained from the IGS, was used to check the robustness of the GPS-TEC variations. Possible anomalies were analyzed for each GNSS station by using the 15-day moving median method. In order to analyze these pre-earthquake ionospheric anomalies, we investigated three indices (Kp, F10.7 and Dst) related to the space weather conditions between 16 October 2015 and 16 December 2015. Solar and geomagnetic indices were obtained from The Oceanic and Atmospheric Administration (NOAA), The Canadian Space Weather Forecast Centre (CSWFC), and the Data Analysis Center for Geomagnetism and Space Magnetism Graduate School of Science, Kyoto University (WDC). This study aims at investigating the possible effects of the earthquake on the TEC variations.
47 CFR 25.109 - Cross-reference.
Code of Federal Regulations, 2014 CFR
2014-10-01
... General § 25.109 Cross-reference. (a) Space and earth stations in the Amateur Satellite Service are licensed under 47 CFR part 97. (b) Ship earth stations in the Maritime Mobile-Satellite Service transmitting in the 1626.5-1646.5 MHz band are subject to licensing under 47 CFR part 80. (c) Earth stations in...
47 CFR 25.109 - Cross-reference.
Code of Federal Regulations, 2013 CFR
2013-10-01
... General § 25.109 Cross-reference. (a) Space and earth stations in the Amateur Satellite Service are licensed under 47 CFR part 97. (b) Ship earth stations in the Maritime Mobile-Satellite Service transmitting in the 1626.5-1646.5 MHz band are subject to licensing under 47 CFR part 80. (c) Earth stations in...
Serologic evaluation of toxoplasmosis in matrimonial women in Babol, Iran.
Youssefi, M R; Sefidgar, A A; Mostafazadeh, A; Omran, S Mahdavi
2007-05-01
To investigate anti-toxoplasmosis in matrimonial women, samples collected from who referred to Babol health center, that is the only pre-marriage laboratory guide center in Babol. This descriptive-cross sectional study has carried out on 241 matrimonial women to consider anti toxoplasmosis antibodies (IgG, IgM) by ELISA (Enzyme Linked Immunosorbant Assay). In this study, 241 women between 13 to 40 years old were considered. The average age was 20.98 years. Of these cases, 47.3% were urban and 52.7% were rural. 63.9% had IgG and 12.4% had IgM anti-toxoplasmosis antibody. This study carried out to determine anti toxoplasmosis antibodies in Babol in the first half of 2004. Dispersed studies have been done to determine the prevalence oftoxoplasmosis in Iran and mostly have reported a high and different prevalence oftoxoplasmosis in different parts of country.
Accuracy of a Flash Glucose Monitoring System in Diabetic Dogs.
Corradini, S; Pilosio, B; Dondi, F; Linari, G; Testa, S; Brugnoli, F; Gianella, P; Pietra, M; Fracassi, F
2016-07-01
A novel flash glucose monitoring system (FGMS) (FreeStyle Libre, Abbott, UK) was recently developed for humans. It continuously measures the interstitial glucose (IG) concentrations for 14 days. To assess the clinical and analytical accuracy of the FGMS in diabetic dogs. Ten client-owned diabetic dogs on insulin treatment. Prospective and observational study. The FGMS was placed on the neck for up to 14 days. During the 1st-2nd, 6-7th, and 13-14th days from application, the IG measurements were compared with the plasma (EDTA) glucose (PG) concentrations analyzed by a reference hexokinase based method. The application and the use of the FGMS were apparently painless, easy, and well tolerated by all dogs. Mild erythema at the site of the application was found in 5/10 dogs at the end of the wearing period. A good correlation between IG and PG concentrations (rho = 0.94; P < .001) was found. The FGMS was 93, 99, and 99% accurate at low, normal, and high blood glucose concentrations. Mean ± standard deviation difference from the reference method was 2.3 ± 46.8 mg/dL. The FGMS is easy to use and is accurate for IG glucose measurement in diabetic dogs. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
GPS/GLONASS Combined Precise Point Positioning with Receiver Clock Modeling
Wang, Fuhong; Chen, Xinghan; Guo, Fei
2015-01-01
Research has demonstrated that receiver clock modeling can reduce the correlation coefficients among the parameters of receiver clock bias, station height and zenith tropospheric delay. This paper introduces the receiver clock modeling to GPS/GLONASS combined precise point positioning (PPP), aiming to better separate the receiver clock bias and station coordinates and therefore improve positioning accuracy. Firstly, the basic mathematic models including the GPS/GLONASS observation equations, stochastic model, and receiver clock model are briefly introduced. Then datasets from several IGS stations equipped with high-stability atomic clocks are used for kinematic PPP tests. To investigate the performance of PPP, including the positioning accuracy and convergence time, a week of (1–7 January 2014) GPS/GLONASS data retrieved from these IGS stations are processed with different schemes. The results indicate that the positioning accuracy as well as convergence time can benefit from the receiver clock modeling. This is particularly pronounced for the vertical component. Statistic RMSs show that the average improvement of three-dimensional positioning accuracy reaches up to 30%–40%. Sometimes, it even reaches over 60% for specific stations. Compared to the GPS-only PPP, solutions of the GPS/GLONASS combined PPP are much better no matter if the receiver clock offsets are modeled or not, indicating that the positioning accuracy and reliability are significantly improved with the additional GLONASS satellites in the case of insufficient number of GPS satellites or poor geometry conditions. In addition to the receiver clock modeling, the impacts of different inter-system timing bias (ISB) models are investigated. For the case of a sufficient number of satellites with fairly good geometry, the PPP performances are not seriously affected by the ISB model due to the low correlation between the ISB and the other parameters. However, the refinement of ISB model weakens the correlation between coordinates and ISB estimates and finally enhance the PPP performance in the case of poor observation conditions. PMID:26134106
Mars rover/sample return mission requirements affecting space station
NASA Technical Reports Server (NTRS)
1988-01-01
The possible interfaces between the Space Station and the Mars Rover/Sample Return (MRSR) mission are defined. In order to constrain the scope of the report a series of seven design reference missions divided into three major types were assumed. These missions were defined to span the probable range of Space Station-MRSR interactions. The options were reduced, the MRSR sample handling requirements and baseline assumptions about the MRSR hardware and the key design features and requirements of the Space Station are summarized. Only the aspects of the design reference missions necessary to define the interfaces, hooks and scars, and other provisions on the Space Station are considered. An analysis of each of the three major design reference missions, is reported, presenting conceptual designs of key hardware to be mounted on the Space Station, a definition of weights, interfaces, and required hooks and scars.
Buonocore, Francesco; Stocchi, Valentina; Nunez-Ortiz, Noelia; Randelli, Elisa; Gerdol, Marco; Pallavicini, Alberto; Facchiano, Angelo; Bernini, Chiara; Guerra, Laura; Scapigliati, Giuseppe; Picchietti, Simona
2017-03-15
Immunoglobulins (Igs) are fundamental components of the adaptive immune system of vertebrates, with the IgT/IgZ isotype specific of Teleosts. In this paper we describe the identification of an IgT heavy chain from the European sea bass (Dicentrarchus labrax L.), its molecular characterization and tissue mRNA localization by in situ hybridization. Sea bass IgT consists of 552 aa (Accession Number KM410929) and it contains a putative 19 amino acids long signal peptide and one potential N-glycosylation site. The C-region consists of four C H domains; each contains the cysteine and tryptophan residues required for their correct folding. Based on the recent sequencing of sea bass genome, we have identified five different genomic contigs bearing exons unequivocally pertaining to IgT (C H 2, C H 3 and C H 4), but none corresponded to a complete IgH locus as IgT sequences were found in the highly fragmented assembled genomic regions which could not be assigned to any major scaffold. The 3D structure of sea bass IgT has been modelled using the crystal structure of a mouse Ig gamma as a template, thus showing that the amino acid sequence is suitable for the expected topology referred to an immunoglobulin-like architecture. The basal expression of sea bass IgT and IgM in different organs has been analysed: gut and gills, important mucosal organs, showed high IgT transcripts levels and this was the first indication of the possible involvement of sea bass IgT in mucosal immune responses. Moreover, sea bass IgT expression increased in gills and spleen after infection with nodavirus, highlighting the importance of IgT in sea bass immune responses. In situ hybridization confirmed the presence of IgT transcripts in the gut and it revealed a differential expression along the intestinal tract, with a major expression in the posterior intestine, suggesting the hindgut as a site for the recruitment of IgT + cells in this species. IgT transcripts were also found in gill filaments and parallel lamellae and, for the first time, we identified scattered IgT positive cells in the liver, with a strong signal in the hepatic parenchyma. In conclusion, we performed a full molecular characterization of IgT in sea bass that points out its possible involvement in mucosal immune responses of this species.
NASA Astrophysics Data System (ADS)
Gandolfi, S.; Poluzzi, L.; Tavasci, L.
2012-12-01
Precise Point Positioning (PPP) is one of the possible approaches for GNSS data processing. As known this technique is faster and more flexible compared to the others which are based on a differenced approach and constitute a reliable methods for accurate positioning of remote GNSS stations, even in some remote area such as Antarctica. Until few years ago one of the major limits of the method was the impossibility to resolve the ambiguity as integer but nowadays many methods are available to resolve this aspect. The first software package permitting a PPP solution was the GIPSY OASIS realized, developed and maintained by JPL (NASA). JPL produce also orbits and files ready to be used with GIPSY. Recently, using these products came possible to resolve ambiguities improving the stability of solutions. PPP permit to estimate position into the reference frame of the orbits (IGS) and when coordinate in others reference frames, such al ITRF, are needed is necessary to apply a transformation. Within his products JPL offer, for each day, a global 7 parameter transformation that permit to locate the survey into the ITRF RF. In some cases it's also possible to create a costumed process and obtain analogous parameters using local/regional reference network of stations which coordinates are available also in the desired reference frame. In this work some tests on accuracy has been carried out comparing different PPP solutions obtained using the same software packages (GIPSY) but considering the ambiguity resolution, the global and regional transformation parameters. In particular two test area have been considered, first one located in Antarctica and the second one in Italy. Aim of the work is the evaluation of the impact of ambiguity resolution and the use of local/regional transformation parameter in the final solutions. Tests shown how the ambiguity resolution improve the precision, especially in the EAST component with a scattering reduction about 8%. And the use of global transformation parameter permit to improve the accuracy of about 59%, 63% and 29% in the three components N E U, but other tests shown how is possible to improve the accuracy of 67% 71% and 53% using regional transformation parameters. Example of the impact of global vs regional parameters transformation in a GPS time series
NASA Astrophysics Data System (ADS)
Hutton, J. J.; Gopaul, N.; Zhang, X.; Wang, J.; Menon, V.; Rieck, D.; Kipka, A.; Pastor, F.
2016-06-01
For almost two decades mobile mapping systems have done their georeferencing using Global Navigation Satellite Systems (GNSS) to measure position and inertial sensors to measure orientation. In order to achieve cm level position accuracy, a technique referred to as post-processed carrier phase differential GNSS (DGNSS) is used. For this technique to be effective the maximum distance to a single Reference Station should be no more than 20 km, and when using a network of Reference Stations the distance to the nearest station should no more than about 70 km. This need to set up local Reference Stations limits productivity and increases costs, especially when mapping large areas or long linear features such as roads or pipelines. An alternative technique to DGNSS for high-accuracy positioning from GNSS is the so-called Precise Point Positioning or PPP method. In this case instead of differencing the rover observables with the Reference Station observables to cancel out common errors, an advanced model for every aspect of the GNSS error chain is developed and parameterized to within an accuracy of a few cm. The Trimble Centerpoint RTX positioning solution combines the methodology of PPP with advanced ambiguity resolution technology to produce cm level accuracies without the need for local reference stations. It achieves this through a global deployment of highly redundant monitoring stations that are connected through the internet and are used to determine the precise satellite data with maximum accuracy, robustness, continuity and reliability, along with advance algorithms and receiver and antenna calibrations. This paper presents a new post-processed realization of the Trimble Centerpoint RTX technology integrated into the Applanix POSPac MMS GNSS-Aided Inertial software for mobile mapping. Real-world results from over 100 airborne flights evaluated against a DGNSS network reference are presented which show that the post-processed Centerpoint RTX solution agrees with the DGNSS solution to better than 2.9 cm RMSE Horizontal and 5.5 cm RMSE Vertical. Such accuracies are sufficient to meet the requirements for a majority of airborne mapping applications.
Variation of 45S rDNA intergenic spacers in Arabidopsis thaliana.
Havlová, Kateřina; Dvořáčková, Martina; Peiro, Ramon; Abia, David; Mozgová, Iva; Vansáčová, Lenka; Gutierrez, Crisanto; Fajkus, Jiří
2016-11-01
Approximately seven hundred 45S rRNA genes (rDNA) in the Arabidopsis thaliana genome are organised in two 4 Mbp-long arrays of tandem repeats arranged in head-to-tail fashion separated by an intergenic spacer (IGS). These arrays make up 5 % of the A. thaliana genome. IGS are rapidly evolving sequences and frequent rearrangements inside the rDNA loci have generated considerable interspecific and even intra-individual variability which allows to distinguish among otherwise highly conserved rRNA genes. The IGS has not been comprehensively described despite its potential importance in regulation of rDNA transcription and replication. Here we describe the detailed sequence variation in the complete IGS of A. thaliana WT plants and provide the reference/consensus IGS sequence, as well as genomic DNA analysis. We further investigate mutants dysfunctional in chromatin assembly factor-1 (CAF-1) (fas1 and fas2 mutants), which are known to have a reduced number of rDNA copies, and plant lines with restored CAF-1 function (segregated from a fas1xfas2 genetic background) showing major rDNA rearrangements. The systematic rDNA loss in CAF-1 mutants leads to the decreased variability of the IGS and to the occurrence of distinct IGS variants. We present for the first time a comprehensive and representative set of complete IGS sequences, obtained by conventional cloning and by Pacific Biosciences sequencing. Our data expands the knowledge of the A. thaliana IGS sequence arrangement and variability, which has not been available in full and in detail until now. This is also the first study combining IGS sequencing data with RFLP analysis of genomic DNA.
Skegro, Darko; Stutz, Cian; Ollier, Romain; Svensson, Emelie; Wassmann, Paul; Bourquin, Florence; Monney, Thierry; Gn, Sunitha; Blein, Stanislas
2017-06-09
Bispecific antibodies (bsAbs) are of significant importance to the development of novel antibody-based therapies, and heavy chain (Hc) heterodimers represent a major class of bispecific drug candidates. Current technologies for the generation of Hc heterodimers are suboptimal and often suffer from contamination by homodimers posing purification challenges. Here, we introduce a new technology based on biomimicry wherein the protein-protein interfaces of two different immunoglobulin (Ig) constant domain pairs are exchanged in part or fully to design new heterodimeric domains. The method can be applied across Igs to design Fc heterodimers and bsAbs. We investigated interfaces from human IgA CH3, IgD CH3, IgG1 CH3, IgM CH4, T-cell receptor (TCR) α/β, and TCR γ/δ constant domain pairs, and we found that they successfully drive human IgG1 CH3 or IgM CH4 heterodimerization to levels similar to or above those of reference methods. A comprehensive interface exchange between the TCR α/β constant domain pair and the IgG1 CH3 homodimer was evidenced by X-ray crystallography and used to engineer examples of bsAbs for cancer therapy. Parental antibody pairs were rapidly reformatted into scalable bsAbs that were free of homodimer traces by combining interface exchange, asymmetric Protein A binding, and the scFv × Fab format. In summary, we successfully built several new CH3- or CH4-based heterodimers that may prove useful for designing new bsAb-based therapeutics, and we anticipate that our approach could be broadly implemented across the Ig constant domain family. To our knowledge, CH4-based heterodimers have not been previously reported. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.
Matin, Somaie; Shahbazi, Gholamreza; Namin, Shervin Tabrizian; Moradpour, Rouhallah; Feizi, Farideh; Piri-Dogahe, Hadi
2017-12-01
Primary maternal infection with toxoplasmosis during pregnancy is frequently associated with transplacental transmission of the parasite to the fetus. This study was conducted to test the utility of PCR assay to detect recent infections with Toxoplasma in aborted women at various gestational ages who referred to Obstetrics and Gynecology Department of Alavi Hospital in Ardabil during 2014 and 2016. Two hundred women with a history of single or repeated abortion were investigated in this study. Blood samples were tested for specific anti-Toxoplasma IgM and IgG antibodies by ELISA. According to the results, 53.5% of the women under study were positive for anti-Toxoplasma antibodies: 4.0% of them had IgM, 43.0% had IgG, and 6.5% had both IgM and IgG. Subsequently, Nested-PCR analysis was used to detect T. gondii DNA in the placenta of subjects. In 10.5% of the women, the results were positive for 529 bp element of T. gondii. Among them, 5 (23.8%) cases were IgM positive, 1 (4.8%) case was IgG positive, and 11 (52.4%) were both IgM and IgG positive. In 4 (19.0%) patients, none of the antibodies were found to be positive. In total, 16 patients had positive results in both ELISA and PCR methods, and 174 cases had negative results for new infection. The findings of this study revealed that T. gondii might be one of the significant factors leading to abortion, and that the analysis of placenta can be important in order to achieve increased detection sensitivity.
TESTS TO ASSESS SENSITIZATION TO ASPERGILLUS FUMIGATUS IN CYSTIC FIBROSIS
Aguiar, Simone Santana; Damaceno, Neiva; Forte, Wilma Carvalho Neves
2017-01-01
ABSTRACT Objective: To evaluate the results of the tests used to identify the IgE mediated sensitization to Aspergillus fumigatus in patients with cystic fibrosis. Methods: This is a cross-sectional descriptive study with a convenience sample of 86 patients diagnosed with cystic fibrosis in the Reference Service in Cystic Fibrosis at a tertiary teaching hospital. The following tests were performed to assess the sensitization to A. fumigatus in patients with cystic fibrosis: Total serum IgE, eosinophil count, fungus detection through oropharyngeal swab or sputum culture, serum-specific IgE, and immediate-type hypersensitivity (IgE) skin tests. We compared the results of the different tests performed. Results: In 33 (38.4%) patients with cystic fibrosis, with ages ranging from 1 to 33 years (median of 8 years), the IgE-mediated A. fumigatus sensitization test results were: in 16 patients, there was an increase in serum-specific IgE (>0.35 kU/L); in 23, skin tests were positive; and six had sensitization in both tests. We observed two patients with eosinophilia (>1,000 eosinophils/mm3) and seven with increasing total serum IgE (>1,000 IU/mL), all of whom obtained negative results in skin tests and had no IgE increase specific to A. fumigatus. A. fumigatus was not detected in oropharyngeal swabs and/or sputum culture of any patients. Conclusions: We conclude that, among the tests used to assess sensitization to A. fumigatus in cystic fibrosis patients, both serum-specific IgE and immediate-type hypersensitivity (IgE) skin tests are required. Serum eosinophilia and respiratory secretion culture were not essential in this study. PMID:28977288
Evaluation of In-House and Commercial Serological Tests for Diagnosis of Human Tularemia
Yanes, Hadjila; Hennebique, Aurélie; Pelloux, Isabelle; Boisset, Sandrine; Bicout, Dominique J.; Caspar, Yvan
2017-01-01
ABSTRACT Tularemia is a zoonosis caused by the bacterium Francisella tularensis. Its specific diagnosis remains based on serological methods, while F. tularensis is rarely detected in clinical samples by culture or PCR. The aim of the present study was to evaluate the performance of the Serion enzyme-linked immunosorbent assay (ELISA) classic Francisella tularensis IgG and IgM tests (Virion/Serion GmbH Institute, Würzburg, Germany) and the VIRapid tularemia immunochromatographic test (ICT) (Vircell, Granada, Spain) compared to that of the in-house microagglutination test (MAT) and indirect immunofluorescence assay (IFA) currently used at the French National Reference Center for Francisella. We evaluated 256 consecutive sera from 208 patients, including 51 confirmed and 23 probable tularemia cases, and 134 control patients not infected with F. tularensis. The IFA tests displayed 72.5% sensitivity for IgM (cutoff titer ≥80) and 74.5% for IgG (cutoff titer ≥160), and 99.3% specificity for both IgM and IgG. Using cutoffs advocated by the manufacturer, the Serion ELISAs displayed 88.2% sensitivity for IgM and 86.3% for IgG antibodies; specificity was 94.8% for IgM and 95.5% for IgG. Compared to MAT and IFA tests, the Serion ELISAs allowed earlier detection of specific antibodies (1 to 2 weeks versus 2 to 3 weeks after the onset of symptoms). The ICT sensitivity and specificity were 90% and 83.6%, respectively, when considering the cutoff advocated by the manufacturer. In conclusion, the Serion ELISAs are useful as screening tests for tularemia diagnosis, but additional confirmatory tests (such as MAT and IFA) are needed, especially in areas of low endemicity. PMID:29118164
2017-01-01
The present study aimed to investigate the distribution of total serum immunoglobulin E (IgE) levels in Korean schoolchildren and to evaluate its utility in the prediction of atopy and allergic diseases. A nationwide, cross-sectional survey was conducted in first grade students from randomly selected elementary and middle schools. Total IgE levels were measured by ImmunoCAP. Skin prick tests were performed for 18 common inhalant allergens to determine the presence of atopy. Children aged 12–13 years and parents of children aged 6–7 years were asked to complete questionnaire assessing allergic diseases. The cut-off levels of total IgE were determined by analyzing receiver operating characteristic curves. The median total IgE level was 86.7 kU/L (range: 1.5–4,523.1) in 3,753 children aged 6–7 years and 94.7 kU/L (range: 1.5–3,000.0) in 3,930 children aged 12–13 years. Total IgE concentrations were higher in children with atopy or allergic diseases than in those without (all P < 0.001). At the cut-off value of 127.7 kU/L, sensitivity, specificity, and positive and negative predictive values (PPV and NPV) were 67.1%, 75.4%, 65.4%, and 76.7%, respectively, in elementary schoolchildren. At the cut-off value of 63.0 kU/L, sensitivity, specificity, PPV, and NPV were 81.9%, 66.6%, 75.0%, and 75.1%, respectively, in middle schoolchildren. PPV and NPV were ≥ 70% when cut-offs of 258.8 kU/L and 38.4 kU/L were used for the diagnosis of atopy in 6–7 year-olds and 12–13 year-olds, respectively. This nationwide population-based study provided the first normal reference ranges of total IgE in Korean schoolchildren. PMID:28378554
Time evolution of an SLR reference frame
NASA Astrophysics Data System (ADS)
Angermann, D.; Gerstl, M.; Kelm, R.; Müller, H.; Seemüller, W.; Vei, M.
2002-07-01
On the basis of LAGEOS-1 and LAGEOS-2 data we computed a 10-years (1990-2000) solution for SLR station positions and velocities. The paper describes the data processing with the DGFI software package DOGS. We present results for station coordinates and their time variation for 41 stations of the global SLR network, and discuss the stability and time evolution of the SLR reference frame established in the same way. We applied different methods to assess the quality and consistency of the SLR results. The results presented in this paper include: (1) a time series of weekly estimated station coordinates; (2) a comparison of a 10-year LAGEOS-1 and LAGEOS-2 solution; (3) a comparison of 2.5-year solutions with the combined 10-year solution to assess the internal stability and the time evolution of the SLR reference frame; (4) a comparison of the SLR reference frame with ITRF97; and (5) a comparison of SLR station velocities with those of ITRF97 and NNR NUVEL-1A.
Maude, Rapeephan R; de Jong, Hanna K; Wijedoru, Lalith; Fukushima, Masako; Ghose, Aniruddha; Samad, Rasheda; Hossain, Mohammed Amir; Karim, Mohammed Rezaul; Faiz, Mohammed Abul; Parry, Christopher M
2015-10-01
To determine the diagnostic accuracy of three rapid diagnostic tests (RDTs) for typhoid fever in febrile hospitalised patients in Bangladesh. Febrile adults and children admitted to Chittagong Medical College Hospital, Bangladesh, were investigated with Bact/Alert(®) blood cultures and real-time PCR to detect Salmonella enterica Typhi and Paratyphi A and assays for Rickettsia, leptospirosis and dengue fever. Acute serum samples were examined with the LifeAssay (LA) Test-it™ Typhoid IgM lateral flow assay detecting IgM antibodies against S. Typhi O antigen, CTKBiotech Onsite Typhoid IgG/IgM Combo Rapid-test cassette lateral flow assay detecting IgG and IgM antibodies against S. Typhi O and H antigens and SD Bioline line assay for IgG and IgM antibodies against S. Typhi proteins. In 300 malaria smear-negative febrile patients [median (IQR) age of 13.5 (5-31) years], 34 (11.3%) had confirmed typhoid fever: 19 positive by blood culture for S. Typhi (three blood PCR positive) and 15 blood culture negative but PCR positive for S. Typhi in blood. The respective sensitivity and specificity of the three RDTs in patients using a composite reference standard of blood culture and/or PCR-confirmed typhoid fever were 59% and 61% for LifeAssay, 59% and 74% for the CTK IgM and/or IgG, and 24% and 96% for the SD Bioline RDT IgM and/or IgG. The LifeAssay RDT had a sensitivity of 63% and a specificity of 91% when modified with a positive cut-off of ≥2+ and analysed using a Bayesian latent class model. These typhoid RDTs demonstrated moderate diagnostic accuracies, and better tests are needed. © 2015 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.
Avian antibodies (IgY) against Trypanosoma cruzi: Purification and characterization studies.
Grando, Thirssa H; Baldissera, Matheus D; de Sá, Mariângela F; do Carmo, Guilherme M; Porto, Bianca Carolina Z; Aguirre, Gisele S V; Azevedo, Maria Isabel; de Jesus, Francielli P K; Santurio, Janio M; Sagrillo, Michele R; Stefani, Lenita Moura; Monteiro, Silvia Gonzalez
2017-10-01
Trypanosoma cruzi is a flagellated protozoan belonging to the Trypanosomatidae family, the etiologic agent of Chagas disease. Currently, there is neither a licensed vaccine nor effective treatment, characterizing an unmet clinical need. The IgY refers to the egg yolk immunoglobulin (Y=yolk) and its production and use are subjects of many studies due to the diversity of its diagnostic and therapeutic applications. Several researchers have shown that the use of specific IgY may prevent and/or control infectious and parasitic diseases. Based on these evidences, the aim of this study was to immunize chickens with trypomastigotes of T. cruzi in order to produce highly effective and pure antibodies (IgY), as well as extract, characterize, quantify, and verify cytotoxic effects of IgY anti-T. cruzi. After the induction of IgY production by chickens, the eggs were collected and the IgY was extracted by method of precipitation of polyethylene glycol 6000. The IgY anti-T. cruzi characterization was performed using polyacrylamide gel electrophoresis (SDS-PAGE), western-blot and enzyme-linked immunosorbent assay (ELISA). Moreover, the cytotoxic or proliferative effects of IgY anti-T. cruzi was verified by MTT assay. The concentration of IgY in yolk was 8.41±1.47mg/mL. The characterization of IgY reveled bands of stained peptides with molecular weight between 75 and 50kDa and 37 and 25kDa. In the ELISA test was observed that there was antigen-antibody reaction throughout the sample period. The concentrations of 1, 5 and 10mg/mL of IgY anti-T. cruzi presented no cytotoxic of proliferative effects in mononuclear and VERO cells in vitro. The results indicated that T. cruzi is able to generate a high production of specific immunoglobulins in chickens, it did not cause damage to the cell membrane and no proliferative effect. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Huang, Zhihui; Ma, Aijun; Wang, Xin'an; Lei, Jilin; Li, Weiye; Wang, Ting; Yang, Zhi; Qu, Jiangbo
2015-01-01
Central Composite Design (CCD) and response surface methodology were used in the experiment to examine the combined effect of temperature (16-28°C) and salinity (18-42) on Hsp70 and IgM genes expression levels in turbot ( Scophthalmus maximus) liver and kidney. The results showed that the coefficients of determination ( R 2 =0.965 2 for liver Hsp70, 0.972 9 for kidney Hsp70, 0.921 for liver IgM and 0.962 1 for kidney IgM) and probability values ( P<0.01) were significant for the regression model. The interactive effect between temperature and salinity on liver Hsp70, kidney Hsp70 and liver IgM were not significant ( P>0.05), while the interactive effect between temperature and salinity on kidney IgM was significant ( P<0.01). The model equation could be used in practice for forecasting Hsp70 and IgM genes expression levels in the liver and kidney of juvenile turbot via applying statistical optimization of the response of interest, at which the maximum liver Hsp70, kidney Hsp70, liver IgM and kidney IgM of 1.48, 1.49, 2.48, and 1.38, respectively, were reached. The present model may be valuable in assessing the feasibility of turbot farming at different geographic locations and, furthermore, could be a useful reference for scientists studying the immunity of turbot.
Environmental control/life support system for Space Station
NASA Technical Reports Server (NTRS)
Miller, C. W.; Heppner, D. B.; Schubert, F. H.; Dahlhausen, M. J.
1986-01-01
The functional, operational, and design load requirements for the Environmental Control/Life Support System (ECLSS) are described. The ECLSS is divided into two groups: (1) an atmosphere management group and (2) a water and waste management group. The interaction between the ECLSS and the Space Station Habitability System is examined. The cruciform baseline station design, the delta and big T module configuration, and the reference Space Station configuration are evaluated in terms of ECLSS requirements. The distribution of ECLSS equipment in a reference Space Station configuration is studied as a function of initial operating conditions and growth orbit capabilities. The benefits of water electrolysis as a Space Station utility are considered.
Glaffig, Markus; Stergiou, Natascha; Hartmann, Sebastian; Schmitt, Edgar; Kunz, Horst
2018-01-08
A MUC1 anticancer vaccine equipped with covalently linked divalent mannose ligands was found to improve the antigen uptake and presentation by targeting mannose-receptor-positive macrophages and dendritic cells. It induced much stronger specific IgG immune responses in mice than the non-mannosylated reference vaccine. Mannose coupling also led to increased numbers of macrophages, dendritic cells, and CD4 + T cells in the local lymph organs. Comparison of di- and tetravalent mannose ligands revealed an increased binding of the tetravalent version, suggesting that higher valency improves binding to the mannose receptor. The mannose-coupled vaccine and the non-mannosylated reference vaccine induced IgG antibodies that exhibited similar binding to human breast tumor cells. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Bor, M V; Jacobsen, I-L Søtang; Gram, J B; Sidelmann, J J
2018-01-01
Background Phadia/EliA fluorescence enzyme immunoassays are widely used automated assays for anticardiolipin (aCL) and anti-β2-glycoprotein I (aβ2GPI) antibodies. To date, cut-off values for these assays have not been evaluated systematically and the evidence behind manufacturer's recommended cut-off values is not clear. Objective To determine Phadia/EliA cut-off values for antiphospholipid antibodies (aPL) according to the procedures suggested by guidelines. Methods A total of 266 blood donors (135 females and 131 males) were included. The pre-handling and analysis of the samples were performed according to the International Society on Thrombosis and Hemostasis (ISTH) guideline for solid phase aPL assays. Cut-off values and corresponding 90% confidence intervals (CI) for each antibody were established and outliers were handled according to the Clinical and Laboratory Standards Institute (CLSI) guideline for reference intervals. Samples from 377 consecutive patients, referred to our thrombophilia center with evidence of thrombosis or pregnancy morbidity were included for aPL testing. Results The in-house 99th (97.5th) percentile cut-off values were 11 (8.7), 12 (6.9) 8.5 (5.0) AU/mL for aβ2GPI IgG, IgM and IgA, and 21 (13) GPL-U/mL and 41 (25) MPL-U/mL for aCL IgG and IgM, respectively. The prevalence of positive results (%) defined by these cut-off values in patients with evidence of thrombosis or pregnancy morbidity was 9.5 (12.2), 1.6 (2.9), and 7.0 (9.9), and 0.8 (3.8) for aβ2GPI IgG, IgM, and aCL IgG and IgM respectively. The use of in-house 99th percentile cut-off values compared to the manufacturer suggested cut-off values resulted in 1 and 39 fewer samples for aβ2GPI and aCL to be classified as positive for aPL, respectively. Conclusions We present Phadia/EliA cut-off values with 90% CI for aPL determined systematically according to the ISTH and CLSI guidelines. These values are different from values previously determined, suggesting variation of aPLs in different populations. Our findings indicate the need for each laboratory to determine/validate assay specific cut-off values for aPL.
Detection of Toxoplasma gondii in Diabetic Patients Using the Nested PCR Assay via RE and B1 Genes
Mousavi, Mohammad; Saravani, Ramin; Jafari Modrek, Mohammad; Shahrakipour, Mahnaz; Sekandarpour, Sina
2016-01-01
Background Toxoplasma gondii is an obligate intracellular protozoan parasite that exists worldwide. Various techniques have been developed for T. gondii detection. Objectives The aim of this study was the detection of T. gondii in diabetic patients with RE and B1 genes and the comparison of these two genes for diagnosis using the nested-PCR assay method. Patients and Methods DNA samples from 205 diabetic patients who had been referred to the diabetes center of Ali Asghar hospital in Zahedan, Iran, were collected and analyzed using the nested-PCR assay method. Toxoplasma antibody data gathered using the enzyme-linked immunosorbent assay (ELISA) method from a previous study was used to group patients. The data were analyzed using SPSS 18. The chi-square test was used for comparison. Results Of the diabetic patients selected, the following results were obtained: 53 (IgG+, IgM+); 20 (IgG-, IgM+); 72 (IgG+, IgM-); and 60 (IgG-, IgM-). The nested-PCR detected the following: in the acute group, 21/53 (39.63%), 30/53 (56.60%) (IgM+, IgG+); in the chronic group, 40/72 (55.56%), 51/72 (70.83%), (IgG+, IgM-); in the false positive group, 18/20 (90%), 17/20 (85%) (IgM+, IgG-); and sero-negative samples of 38/60 (63.33%) and 60/ 41 (77.35%) for RE and B1 genes, respectively. The prevalence of toxoplasmosis showed positive in patients with diabetes in the B1 gene 139 (67.8%) and RE gene 117 (57.1%). Conclusions Our study demonstrated that the B1 gene, more so than the RE gene, showed positive samples and can be used to detect toxoplasmosis, although the B1 gene, in comparison to the RE gene, did not show any superiority of molecular diagnosing capability. Results also showed that toxoplasma molecular detection methods can be used instead of routine serological detection methods in a clinical laboratory testing. PMID:27127588
NASA Astrophysics Data System (ADS)
Gruszczynska, Marta; Rosat, Severine; Klos, Anna; Gruszczynski, Maciej; Bogusz, Janusz
2018-03-01
We described a spatio-temporal analysis of environmental loading models: atmospheric, continental hydrology, and non-tidal ocean changes, based on multichannel singular spectrum analysis (MSSA). We extracted the common annual signal for 16 different sections related to climate zones: equatorial, arid, warm, snow, polar and continents. We used the loading models estimated for a set of 229 ITRF2014 (International Terrestrial Reference Frame) International GNSS Service (IGS) stations and discussed the amount of variance explained by individual modes, proving that the common annual signal accounts for 16, 24 and 68% of the total variance of non-tidal ocean, atmospheric and hydrological loading models, respectively. Having removed the common environmental MSSA seasonal curve from the corresponding GPS position time series, we found that the residual station-specific annual curve modelled with the least-squares estimation has the amplitude of maximum 2 mm. This means that the environmental loading models underestimate the seasonalities observed by the GPS system. The remaining signal present in the seasonal frequency band arises from the systematic errors which are not of common environmental or geophysical origin. Using common mode error (CME) estimates, we showed that the direct removal of environmental loading models from the GPS series causes an artificial loss in the CME power spectra between 10 and 80 cycles per year. When environmental effect is removed from GPS series with MSSA curves, no influence on the character of spectra of CME estimates was noticed.
NASA Astrophysics Data System (ADS)
Gruszczynska, Marta; Rosat, Severine; Klos, Anna; Gruszczynski, Maciej; Bogusz, Janusz
2018-05-01
We described a spatio-temporal analysis of environmental loading models: atmospheric, continental hydrology, and non-tidal ocean changes, based on multichannel singular spectrum analysis (MSSA). We extracted the common annual signal for 16 different sections related to climate zones: equatorial, arid, warm, snow, polar and continents. We used the loading models estimated for a set of 229 ITRF2014 (International Terrestrial Reference Frame) International GNSS Service (IGS) stations and discussed the amount of variance explained by individual modes, proving that the common annual signal accounts for 16, 24 and 68% of the total variance of non-tidal ocean, atmospheric and hydrological loading models, respectively. Having removed the common environmental MSSA seasonal curve from the corresponding GPS position time series, we found that the residual station-specific annual curve modelled with the least-squares estimation has the amplitude of maximum 2 mm. This means that the environmental loading models underestimate the seasonalities observed by the GPS system. The remaining signal present in the seasonal frequency band arises from the systematic errors which are not of common environmental or geophysical origin. Using common mode error (CME) estimates, we showed that the direct removal of environmental loading models from the GPS series causes an artificial loss in the CME power spectra between 10 and 80 cycles per year. When environmental effect is removed from GPS series with MSSA curves, no influence on the character of spectra of CME estimates was noticed.
Observed TEC Anomalies by GNSS Sites Preceding the Aegean Sea Earthquake of 2014
NASA Astrophysics Data System (ADS)
Ulukavak, Mustafa; Yal&ccedul; ınkaya, Mualla
2016-11-01
In recent years, Total Electron Content (TEC) data, obtained from Global Navigation Satellites Systems (GNSS) receivers, has been widely used to detect seismo-ionospheric anomalies. In this study, Global Positioning System - Total Electron Content (GPS-TEC) data were used to investigate ionospheric abnormal behaviors prior to the 2014 Aegean Sea earthquake (40.305°N 25.453°E, 24 May 2014, 09:25:03 UT, Mw:6.9). The data obtained from three Continuously Operating Reference Stations in Turkey (CORS-TR) and two International GNSS Service (IGS) sites near the epicenter of the earthquake is used to detect ionospheric anomalies before the earthquake. Solar activity index (F10.7) and geomagnetic activity index (Dst), which are both related to space weather conditions, were used to analyze these pre-earthquake ionospheric anomalies. An examination of these indices indicated high solar activity between May 8 and 15, 2014. The first significant increase (positive anomalies) in Vertical Total Electron Content (VTEC) was detected on May 14, 2014 or 10 days before the earthquake. This positive anomaly can be attributed to the high solar activity. The indices do not imply high solar or geomagnetic activity after May 15, 2014. Abnormal ionospheric TEC changes (negative anomaly) were observed at all stations one day before the earthquake. These changes were lower than the lower bound by approximately 10-20 TEC unit (TECU), and may be considered as the ionospheric precursor of the 2014 Aegean Sea earthquake
Effects of Space Radiation on Humoral and Cellular Immunity in Rhesus Monkeys.
1992-12-01
55318-1084) immunoplates that are routinely used for quantitative assays of human Ig levels. It seemed justified to use the human system to test the...of Ig between the irradiated and control monkeys of different ages. The tests were set up and read at 18 and 72 h by the same operator, taking careful...note of the lot number and the standard reference curves for each test kit. The samples were suitably diluted to obtain clear-cut reactions (i.e
A prospective study of Toxoplasma-positive pregnant women in southern Brazil: a health alert.
Higa, Lourenço T; Araújo, Silvana M; Tsuneto, Luiza; Castilho-Pelloso, Marcela; Garcia, João L; Santana, Rosangela G; Falavigna-Guilherme, Ana L
2010-06-01
We evaluated anti-Toxoplasma gondii IgM-reactive pregnant women seen at a high-risk pregnancy outpatient clinic. From March 2005 to January 2008 in Paraná, Brazil, pregnant women seen by the Brazilian Public Health System, in any gestational period, who were anti-T. gondii IgM-positive, were followed. Clinical symptoms were noted, and tests performed including IgA, IgG avidity, ultrasonogram, and amniocentesis (PCR/inoculation in mice). Of 75 patients, 8 showed low, 3 intermediate and 31 high IgG avidity. Of those who underwent the avidity test, 31 (70.5%) were in the second trimester of pregnancy. Thirty-two (42.7%) pregnant women received specific treatment. Six received triple combination treatment; in three, tachyzoites were isolated, although only one was PCR-positive, showing changes in the cerebral sonogram, borderline IgA, and the Sabin tetrad. One fetus died, and one non-reactive IgM pregnant woman showed ocular recurrence. The municipality of residence, contact with cats during adulthood, and ingestion of unpasteurized milk were shown to be important risk factors. Congenital toxoplasmosis was observed in a pregnancy referred late for treatment. Follow-up of children born to mothers with diagnosed or suspected acute toxoplasmosis is crucial in the management of the changes that toxoplasmosis may cause. 2010 Royal Society of Tropical Medicine and Hygiene. Published by Elsevier Ltd. All rights reserved.
van der Hoek, W; Wielders, C C H; Schimmer, B; Wegdam-Blans, M C A; Meekelenkamp, J; Zaaijer, H L; Schneeberger, P M
2012-11-01
The presence of a high phase I IgG antibody titre may indicate chronic infection and a risk for the transmission of Coxiella burnetii through blood transfusion. The outbreak of Q fever in the Netherlands allowed for the comparison of an enzyme immunoassay (EIA) with the reference immunofluorescence assay (IFA) in a large group of individuals one year after acute Q fever. EIA is 100 % sensitive in detecting high (≥1:1,024) phase I IgG antibody titres. The cost of screening with EIA and confirming all EIA-positive results with IFA is much lower than screening all donations with IFA. This should be taken into account in cost-effectiveness analyses of screening programmes.
Software User’s Manual for Stability and Transition Analysis with the Codes LSH and PSH
1993-09-01
thermka(n) = K amul(n) = IA ainu2(n) = P2 dlqk(n,i) d2qk(n,ls) = aQiaQI’ dlqmul(n,i) aQi’ a2p• d2qmul (n,ls) a 8aQ -’ dlqmu2(n,i) - 19, (•Qi d2qmu2(n...same location, ampmax (it, iz) 45 7. growth rate profiles (n = O,jx) of ig-th variable at the location where the mass - flow disturbance of the reference...mode (ttr, izr) is maximum, grate (n, it, iz, ig). Here ig = 1, .., 4 representing growth rates for i, ’, •, and mass flow ,ii, re- spectively. 6.1.8
NASA Astrophysics Data System (ADS)
Siejka, Zbigniew
2017-09-01
GNSS systems are currently the basic tools for determination of the highest precision station coordinates (e.g. basic control network stations or stations used in the networks for geodynamic studies) as well as for land, maritime and air navigation. All of these tasks are carried out using active, large scale, satellite geodetic networks which are complex, intelligent teleinformatic systems offering post processing services along with corrections delivered in real-time for kinematic measurements. Many countries in the world, also in Europe, have built their own multifunctional networks and enhance them with their own GNSS augmentation systems. Nowadays however, in the era of international integration, there is a necessity to consider collective actions in order to build a unified system, covering e.g. the whole Europe or at least some of its regions. Such actions have already been undertaken in many regions of the world. In Europe such an example is the development for EUPOS which consists of active national networks built in central eastern European countries. So far experience and research show, that the critical areas for connecting these networks are border areas, in which the positioning accuracy decreases (Krzeszowski and Bosy, 2011). This study attempts to evaluate the border area compatibility of Polish ASG-EUPOS (European Position Determination System) reference stations and Ukrainian GeoTerrace system reference stations in the context of their future incorporation into the EUPOS. The two networks analyzed in work feature similar hardware parameters. In the ASG-EUPOS reference stations network, during the analyzed period, 2 stations (WLDW and CHEL) used only one system (GPS), while, in the GeoTerrace network, all the stations were equipped with both GPS and GLONASS receivers. The ASG EUPOS reference station network (95.6%) has its average completeness greater by about 6% when compared to the GeoTerrace network (89.8%).
Use of RTIGS data streams for validating the performance of the IGS Ultra-Rapid products
NASA Astrophysics Data System (ADS)
Thaler, Gottfried; Weber, Robert
2010-05-01
The IGS (International GNSS Service) Real-Time Working Group (RTIGS) disseminates for several years raw observation data of a globally distributed steady growing station network in real-time via the internet. This observation data can be used for validating the performance of the IGS predicted orbits and clocks (Ultra-Rapid (IGU)). Therefore, based on pre-processed ITRF- station coordinates, clock corrections w.r.t GPS-Time for GPS-satellites and site-receivers as well as satellite orbits are calculated in quasi real-time and compared to the IGU solutions. The Institute for "Geodesy and Geophysics" of the Technical University of Vienna develops based on the software RTIGS Multicast Receive (RTIGSMR) provided by National Resources Canada (NRCan) the software RTIGU-Control. Using Code-smoothed observations RTIGU-Control calculates in a first step by means of a linear KALMAN-Filter and based on the orbit information of the IGUs real-time clock corrections and clock drifts w.r.t GPS-Time for the GPS-satellites and stations. The second extended KALMAN-Filter (kinematic approach) uses again the Code-smoothed observations corrected for the clock corrections of step 1 to calculate the positions and velocities of the satellites. The calculation interval is set to 30 seconds. The results and comparisons to IGU-products are displayed online but also stored as clock-RINEX- and SP3-files on the ftp-server of the institute, e.g. for validation of the performance of the IGU predicted products. A comparison to the more precise but delayed issued IGS Rapid products (IGR) allows also to validate the performance of RTIGU-Control. To carry out these comparisons the MatLab routine RTIGU-Analyse was established. This routine is for example able to import and process standard clock-RINEX-files of several sources and delivers a variety of comparisons both in graphical or numerical form. Results will become part of this presentation. Another way to analyse the quality and consistency of the RTIGU-Control products is to use them for positioning in post-processing mode. Preliminary results are already available and will also be presented. Further investigations will deal with upgrading RTIGU-Control to become independent of the IGU products. This means to initialize the KALMAN-Filter process using the orbits (and also clocks) from IGU but to use for all further calculation steps the own established orbits. This procedure results in totally independent satellite orbit and clock corrections which could be used for example instead of the broadcast ephemerides in a large number of real-time PPP applications.
Kirkeby, Line; Rasmussen, Trine Tang; Reinholdt, Jesper; Kilian, Mogens
2000-01-01
Certain bacteria, including overt pathogens as well as commensals, produce immunoglobulin A1 (IgA1) proteases. By cleaving IgA1, including secretory IgA1, in the hinge region, these enzymes may interfere with the barrier functions of mucosal IgA antibodies, as indicated by experiments in vitro. Previous studies have suggested that cleavage of IgA1 in nasal secretions may be associated with the development and perpetuation of atopic disease. To clarify the potential effect of IgA1 protease-producing bacteria in the nasal cavity, we have analyzed immunoglobulin isotypes in nasal secretions of 11 healthy humans, with a focus on IgA, and at the same time have characterized and quantified IgA1 protease-producing bacteria in the nasal flora of the subjects. Samples in the form of nasal wash were collected by using a washing liquid that contained lithium as an internal reference. Dilution factors and, subsequently, concentrations in undiluted secretions could thereby be calculated. IgA, mainly in the secretory form, was found by enzyme-linked immunosorbent assay to be the dominant isotype in all subjects, and the vast majority of IgA (median, 91%) was of the A1 subclass, corroborating results of previous analyses at the level of immunoglobulin-producing cells. Levels of serum-type immunoglobulins were low, except for four subjects in whom levels of IgG corresponded to 20 to 66% of total IgA. Cumulative levels of IgA, IgG, and IgM in undiluted secretions ranged from 260 to 2,494 (median, 777) μg ml−1. IgA1 protease-producing bacteria (Haemophilus influenzae, Streptococcus pneumoniae, or Streptococcus mitis biovar 1) were isolated from the nasal cavities of seven subjects at 2.1 × 103 to 7.2 × 106 CFU per ml of undiluted secretion, corresponding to 0.2 to 99.6% of the flora. Nevertheless, α-chain fragments characteristic of IgA1 protease activity were not detected in secretions from any subject by immunoblotting. Neutralizing antibodies to IgA1 proteases of autologous isolates were detected in secretions from five of the seven subjects but not in those from two subjects harboring IgA1 protease-producing S. mitis biovar 1. α-chain fragments different from Fcα and Fdα were detected in some samples, possibly reflecting nonspecific proteolytic activity of microbial or host origin. These results add to previous evidence for a role of secretory immunity in the defense of the nasal mucosa but do not help identify conditions under which bacterial IgA1 proteases may interfere with this defense. PMID:10618273
2006-02-01
WHOI- 2006 -06 Woods Hole Oceanographic Institution 1930 Stratus Ocean Reference Station (20°S, 85°W) Mooring Recovery and Deployment Cruise RN Ronald...Environmental Technology Laboratory, 3University of Colorado, CIRES, 4University of Miami, 5University of Concepcion February 2006 Technical Report...Institution Woods Hole, MA 02543 UOP Technical Report 2006 -01 WHOI- 2006 -06 UOP- 2006 -01 Stratus Ocean Reference Station (20*S, 85*W) Mooring Recovery and
NASA Astrophysics Data System (ADS)
Chamot-Rooke, N.; Le Pichon, X.
1999-12-01
GPS measurements acquired over Southeast Asia in 1994 and 1996 in the framework of the GEODYSSEA program revealed that a large piece of continental lithosphere comprising the Indochina Peninsula, Sunda shelf and part of Indonesia behaves as a rigid `Sundaland' platelet. A direct adjustment of velocity vectors obtained in a Eurasian frame of reference shows that Sundaland block is rotating clockwise with respect to Eurasia around a pole of rotation located south of Australia. We present here an additional check of Sundaland motion that uses earthquakes slip vectors at Sunda and Philippine trenches. Seven sites of the GEODYSSEA network are close to the trenches and not separated from them by large active faults (two at Sumatra Trench, three at Java Trench and two at the Philippine Trench). The difference between the vector at the station and the adjacent subducting plate vector defines the relative subduction motion and should thus be aligned with the subduction earthquake slip vectors. We first derive a frame-free solution that minimizes the upper plate (or Sundaland) motion. When corrected for Australia-Eurasia and Philippines-Eurasia NUVEL1-A motion, the misfit between GPS and slip vectors azimuths is significant at 95% confidence, indicating that the upper plate does not belong to Eurasia. We then examine the range of solutions compatible with the slip vectors azimuths and conclude that the minimum velocity of Sundaland is a uniform 7-10 mm/a eastward velocity. However, introducing the additional constraint of the fit of the GEODYSSEA sites with the Australian IGS reference ones, or tie with the NTUS Singapore station, leads to a much narrower range of solutions. We conclude that Sundaland has an eastward velocity of about 10 mm/a on its southern boundary increasing to 16-18 mm/a on its northern boundary.
Kenney, Terry A.
2010-01-01
Operational procedures at U.S. Geological Survey gaging stations include periodic leveling checks to ensure that gages are accurately set to the established gage datum. Differential leveling techniques are used to determine elevations for reference marks, reference points, all gages, and the water surface. The techniques presented in this manual provide guidance on instruments and methods that ensure gaging-station levels are run to both a high precision and accuracy. Levels are run at gaging stations whenever differences in gage readings are unresolved, stations may have been damaged, or according to a pre-determined frequency. Engineer's levels, both optical levels and electronic digital levels, are commonly used for gaging-station levels. Collimation tests should be run at least once a week for any week that levels are run, and the absolute value of the collimation error cannot exceed 0.003 foot/100 feet (ft). An acceptable set of gaging-station levels consists of a minimum of two foresights, each from a different instrument height, taken on at least two independent reference marks, all reference points, all gages, and the water surface. The initial instrument height is determined from another independent reference mark, known as the origin, or base reference mark. The absolute value of the closure error of a leveling circuit must be less than or equal to ft, where n is the total number of instrument setups, and may not exceed |0.015| ft regardless of the number of instrument setups. Closure error for a leveling circuit is distributed by instrument setup and adjusted elevations are determined. Side shots in a level circuit are assessed by examining the differences between the adjusted first and second elevations for each objective point in the circuit. The absolute value of these differences must be less than or equal to 0.005 ft. Final elevations for objective points are determined by averaging the valid adjusted first and second elevations. If final elevations indicate that the reference gage is off by |0.015| ft or more, it must be reset.
Corticosteroid for IgA Nephropathy: Are They Really Therapeutic?
Lin, Yujia; Jia, Junya; Guo, Yipeng; He, Dandan; Zhang, Yaru; Wang, Fuzhen; Yan, Tiekun; Liu, Youxia; Lin, Shan
2018-06-06
IgA nephropathy (IgAN) is a common chronic glomerular disease that, in most patients, slowly progresses to end-stage kidney disease. The therapy with corticosteroid in IgAN is still a worldwide problem that is confusing the clinicians. MEDLINE, EMBASE, the Cochrane Library, and article reference lists were searched for randomized controlled trials (RCTs) that compared corticosteroids with placebo and any other non-immunosuppressive agents in treating IgAN. Twelve RCTs involving 1,057 patients were included. Overall, we found that steroids had statistically significant effects in preventing the decline in renal function (relative risk 0.42, 95% CI 0.25-0.71, p < 0.001) and reducing proteinuria (SMD: -0.58 g/day, 95% CI -0.80 to -0.36 g/day) in patients with IgAN. The association between glucocorticoid and risk of kidney outcome was not modified by steroids' type (prednisone or methylprednisone), dose (≤30 or > 30 mg/day), duration (≤8 or > 8 months), or serum creatinine (< 1.10 or ≥1.10 mg/dL). But steroids increased the risk of side effects such as gastrointestinal and endocrinium symptoms. This study provides the clear beneficial effects of the steroids therapy on the kidney function and proteinuria, although it should be used with caution. © 2018 S. Karger AG, Basel.
Costa, Juan G; Peretti, Leandro E; García, Valeria S; Peverengo, Luz; González, Verónica D G; Gugliotta, Luis M; Dalla Fontana, Maria L; Lagier, Claudia M; Marcipar, Iván S
2017-03-01
P35 and P22 Toxoplasma gondii proteins are recognized by specific IgG at the early infection stage, making them ideal for acute toxoplasmosis pregnancy control. Both proteins have been studied to discriminate between acute and chronic toxoplasmosis. However, results were hardly comparable because different protein obtainment procedures led to different antigens, the reference panels used were not optimally typified, and avidity tests were either not performed or narrowly examined. We bioinformatically predicted P35 and P22 regions with the highest density of epitopes, and expressed them in pET32/BL21DE3 alternative expression system, obtaining the soluble proteins rP35a and rP22a. We assessed their diagnostic performance using pregnant woman serum samples typified as: not infected, NI (IgG-, IgM-), typical-chronic, TC (IgM-, IgG+), presumably acute, A (IgG+, IgM+, low-avidity IgG), and recently chronic, RC (IgG+, IgM+, high-avidity IgG). rP35a performed better than rP22a to differentiate A from RC, the areas under the curve (AUC) being 0.911 and 0.818, respectively. They, however, performed similarly to differentiate A from TC+RC (AUC: 0.915 and 0.907, respectively). rP35a and rP22a evaluation by avidity ELISA to discriminate A from RC rendered AUC values of 0.974 and 0.921, respectively. The indirect ELISA and avidity ELISA results analyzed in tandem were consistent with those obtained using commercial kits. rP35a and rP22a features suggest that, with complementary use, they could replace parasite lysate for toxoplasmosis infection screening and for acute toxoplasmosis diagnosis. Our proposal should be validated by a longitudinal study and may lead to a reliable toxoplasmosis pregnancy control, performing tests in only one serum sample.
Guerrero-Ramos, Alvaro; Patel, Mauli; Kadakia, Kinjal; Haque, Tanzina
2014-06-01
The Architect EBV antibody panel is a new chemiluminescence immunoassay system used to determine the stage of Epstein-Barr virus (EBV) infection based on the detection of IgM and IgG antibodies to viral capsid antigen (VCA) and IgG antibodies against Epstein-Barr nuclear antigen 1 (EBNA-1). We evaluated its diagnostic accuracy in immunocompetent adolescents and young adults with clinical suspicion of infectious mononucleosis (IM) using the RecomLine EBV IgM and IgG immunoblots as the reference standard. In addition, the use of the antibody panel in a sequential testing algorithm based on initial EBNA-1 IgG analysis was assessed for cost-effectiveness. Finally, we investigated the degree of cross-reactivity of the VCA IgM marker during other primary viral infections that may present with an EBV IM-like picture. High sensitivity (98.3% [95% confidence interval {CI}, 90.7 to 99.7%]) and specificity (94.2% [95% CI, 87.9 to 97.8%]) were found after testing 162 precharacterized archived serum samples. There was perfect agreement between the use of the antibody panel in sequential and parallel testing algorithms, but substantial cost savings (23%) were obtained with the sequential strategy. A high rate of reactive VCA IgM results was found in primary cytomegalovirus (CMV) infections (60.7%). In summary, the Architect EBV antibody panel performs satisfactorily in the investigation of EBV IM in immunocompetent adolescents and young adults, and the application of an EBNA-1 IgG-based sequential testing algorithm is cost-effective in this diagnostic setting. Concomitant testing for CMV is strongly recommended to aid in the interpretation of EBV serological patterns. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
Cimon, B.; Chemla, C.; Darde, M. L.; Delhaes, L.; L'Ollivier, C.; Godineau, N.; Houze, S.; Paris, L.; Quinio, D.; Robert-Gangneux, F.; Villard, O.; Villena, I.; Candolfi, E.; Pelloux, H.
2013-01-01
Classically, Toxoplasma infection is associated with high levels of specific IgM antibody and a rise in specific IgG levels 1 to 3 weeks later. Atypical IgG seroconversion, without IgM detection or with transient IgM levels, has been described during serologic follow-up of seronegative pregnant women and raises difficulties in interpreting the results. To evaluate the frequency and the characteristics of these atypical cases of seroconversion, an investigation was conducted within the French National Reference Center for Toxoplasmosis, from which 26 cases collected from 12 laboratories belonging to the network were identified. The aim of this work was to retrospectively analyze the results of serologic testing, the treatments administered, and the results of prenatal and postnatal follow-up for these women. In each case, IgG antibodies were detected using both screening and confirmatory tests. IgM antibodies were not detected in 15 cases, and the levels were equivocal or low-positive in 11 cases. The IgG avidity results were low in 16 cases and high in one case. Most of the pregnant women (22/26) were treated with spiramycin from the time that IgG antibodies appeared until delivery. Amniotic fluid was analyzed for Toxoplasma gondii DNA by PCR in 11/26 cases, and the results were negative in all cases. Congenital toxoplasmosis was ruled out in 12/26 newborns. There was no abnormality observed at birth for 10 newborns and no information available for 4 newborns. In conclusion, when the interpretation of serological results is so difficult, it seems cautious to initiate treatment by spiramycin and to follow the pregnant women and their newborns. PMID:23616461
Fiocchi, Alessandro; Besana, Roberto; Rydén, Ann-Christine; Terracciano, Luigi; Andreotti, Massimo; Arrigoni, Sergio; Martelli, Alberto
2004-10-01
Allergy-like symptoms are common in young children, but the case history and physical examination cannot identify the underlying origins of overlapping symptom profiles. To evaluate a blood test, Phadiatop Infant (Pharmacia Diagnostics AB, Uppsala, Sweden), for differentiating the capability of IgE-mediated disease in young children with recurrent wheezing, eczema, or both. One hundred forty-seven children (mean age, 2.0 years) were consecutively referred to 2 allergy centers by their primary care physician for recurrent wheezing, eczema, or both. The allergist's clinical evaluation included medical history, physical examination, skin prick testing with inhalant and food allergens, and specific IgE determinations in blood. The accuracy of Phadiatop Infant was evaluated in a masked manner against the allergist's final diagnosis. Sixty-nine children had wheezing, 69 had eczema, and 9 had both symptoms. Sixty-one children were clinically diagnosed as having IgE-mediated allergy, 78 as having non-IgE-associated disease, and 8 as having an inconclusive diagnosis. Fifty-six of the 61 children with IgE-mediated allergy had positive Phadiatop Infant test results, and 64 of 78 without the condition had negative results. Sensitivity was 92% and specificity was 82%, with positive and negative predictive values of 80% and 93%, respectively. Thirteen children with a positive Phadiatop Infant test result and a negative final diagnosis were retested after 2 years; 12 of them were diagnosed as having IgE-mediated allergy using a masked evaluation. The Phadiatop Infant blood test discriminates between IgE- and non-IgE-mediated symptoms in children younger than 4 years.
Patel, Mauli; Kadakia, Kinjal; Haque, Tanzina
2014-01-01
The Architect EBV antibody panel is a new chemiluminescence immunoassay system used to determine the stage of Epstein-Barr virus (EBV) infection based on the detection of IgM and IgG antibodies to viral capsid antigen (VCA) and IgG antibodies against Epstein-Barr nuclear antigen 1 (EBNA-1). We evaluated its diagnostic accuracy in immunocompetent adolescents and young adults with clinical suspicion of infectious mononucleosis (IM) using the RecomLine EBV IgM and IgG immunoblots as the reference standard. In addition, the use of the antibody panel in a sequential testing algorithm based on initial EBNA-1 IgG analysis was assessed for cost-effectiveness. Finally, we investigated the degree of cross-reactivity of the VCA IgM marker during other primary viral infections that may present with an EBV IM-like picture. High sensitivity (98.3% [95% confidence interval {CI}, 90.7 to 99.7%]) and specificity (94.2% [95% CI, 87.9 to 97.8%]) were found after testing 162 precharacterized archived serum samples. There was perfect agreement between the use of the antibody panel in sequential and parallel testing algorithms, but substantial cost savings (23%) were obtained with the sequential strategy. A high rate of reactive VCA IgM results was found in primary cytomegalovirus (CMV) infections (60.7%). In summary, the Architect EBV antibody panel performs satisfactorily in the investigation of EBV IM in immunocompetent adolescents and young adults, and the application of an EBNA-1 IgG-based sequential testing algorithm is cost-effective in this diagnostic setting. Concomitant testing for CMV is strongly recommended to aid in the interpretation of EBV serological patterns. PMID:24695777
Galkin, O Yu; Besarab, A B; Lutsenko, T N
2017-01-01
The goal of this work was to study sensitivity and specificity of the developed ELISA set for the identification of IgG antibodies against Chlamydia trachomatis HSP-60 (using biotinylated tyramine-based signal amplification system). The study was conducted using a panel of characterized sera, as well as two reference ELISA sets of similar purpose. According to the results of ELISA informative value parameters, the ELISA we have developed showed the highest specificity and sensitivity parameters (no false negative or false positive results were registered). In 4 out of 15 intralaboratory panel serum samples initially identified as negative, anti-HSP-60 IgG-antibodies test result in reference ELISA sets upon dilution changed from negative to positive. The nature of titration curves of false negative sera and commercial monoclonal antibodies А57-В9 against C. trachomatis HSP-60 after incubation for 24 h was indicative of the presence of anti-idiotypic antibodies in these samples. Upon sera dilution, idiotypic-anti-idiotypic complexes dissociated, which caused the change of test result. High informative value of the developed ELISA set for identification of IgG antibodies against C. trachomatis HSP-60 has been proven. Anti-idiotypic antibodies possessing C. trachomatis anti-HSP-60 activity and being one of the causes of false negative results of the relevant ELISA-based tests have been identified in blood sera of individuals infected with chlamydial genitourinary infection agents.
Diagnostic Performance of Serum IgG4 Levels in Patients With IgG4-Related Disease
Yu, Kuang-Hui; Chan, Tien-Ming; Tsai, Ping-Han; Chen, Ching-Hui; Chang, Pi-Yueh
2015-01-01
Abstract The aim of this study is to study the clinical features and diagnostic performance of IgG4 in Chinese populations with IgG4-related diseases (IgG4-RDs). The medical records of 2901 adult subjects who underwent serum IgG4 level tests conducted between December 2007 and May 2014 were reviewed. Serum concentrations of IgG4 were measured in 2901 cases, including 161 (5.6%) patients with IgG4-RD and 2740 (94.4%) patients without IgG4-RD (non-IgG4-RD group). The mean age of the IgG4-RD patients was 58.4 ± 16.1 years (range: 21–87), and 48 (29.8%) were women. The mean serum IgG4 level was significantly much higher in IgG4-RD patients than in non-IgG4-RD (1062.6 vs 104.3 mg/dL, P < 0.001) participants. For IgG4 >135 mg/dL, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), likelihood ratio (LR)+, and LR− were 86%, 77%, 18%, 99%, 3.70, and 0.19, respectively. When the upper limit of normal was doubled for an IgG4 >270 mg/dL, the corresponding data were 75%, 94%, 43%, 98%, 12.79, and 0.26, respectively. For IgG4 >405 mg/dL (tripling the upper limit of normal), the corresponding data were 62%, 98%, 68%, 98%, 37.00, and 0.39, respectively. When calculated according to the manufacturer's package insert cutoff (>201 mg/dL) for the diagnosis of IgG4-RD, the corresponding sensitivity, specificity, PPV, NPV, LR+, and LR− were 80%, 89%, 29%, 99%, 7.00, and 0.23, respectively. For IgG4 >402 mg/dL (>2× the upper limit of the normal range), the corresponding data were 62%, 98%, 68%, 98%, 36.21, and 0.39, respectively. For IgG4 >603 mg/dL (>3× the upper limit of the normal range), the corresponding data were 50%, 99%, 84%, 97%, 90.77 and 0.51, respectively. The optimal cutoff value of serum IgG4 (measured by nephelometry using a Siemens BN ProSpec instrument and Siemens reagent) for the diagnosis of IgG4-RD was 248 mg/dL, the sensitivity and specificity were 77.6% and 92.8%, respectively. The present study demonstrated that 2 or 3 times the upper limit of the manufacturer's reference range of the IgG4 level was a useful marker for the diagnosis of various types of IgG4-RD and the optimal cutoff level was 248 mg/dL. PMID:26469909
Combined orbits and clocks from the IGS 2nd reprocessing
NASA Astrophysics Data System (ADS)
Griffiths, J.; Ray, J.
2016-12-01
In early 2015, the Analysis Centers (ACs) of the International GNSS Service (IGS) completed their second reanalysis of the full history of globally distributed GPS and GLONASS data collected since 1994. The suite of reprocessed AC solutions includes daily product files containing station positions, Earth rotation parameters, satellite orbits and clocks. This second reprocessing—or repro2—provided the IGS contribution to ITRF2014; it follows the successful first reprocessing, which provided the IGS input for ITRF2008. For this poster, we will discuss the newly combined repro2 GPS orbits and clocks. We also revisit our previous analysis of orbit day-boundary discontinuities with several significant changes and improvements: 1) Orbit discontinuities for the contributing ACs were studied in addition to those for the IGS repro2 combined orbits. (2) Apart from homogeneous reprocessing with updated analysis models, the main difference compared to the IGS Final operational products is that NOAA/NGS inputs were not submitted for the IGS reprocessing, yet they contribute heavily in the operational orbits in recent years. (3) Also, during spring 2016, the ESA modified their orbit model so that it is no longer consistent with the one used for reprocessing. A much longer span of orbits was available now, up to 11.2 years for some individual satellites, which allows a far better resolution of spectral features. 4) The procedure to compute orbit discontinuities has been further refined to account for extrapolation edge effects, improved geopotential fields, and to allow for spectral analysis of a longer time series of jumps. The satellite position time series used are complete enough that linear interpolation is necessary for only sparse gaps. So the key results are based on standard FFT power spectra (stacked over the available constellation and lightly smoothed). However, we have also computed Lomb-Scargle periodgrams to provide higher frequency resolution of some spectral peaks and to permit tests of the effect of excluding eclipse periods.
Pan, Shuguo; Chen, Weirong; Jin, Xiaodong; Shi, Xiaofei; He, Fan
2015-07-22
Satellite orbit error and clock bias are the keys to precise point positioning (PPP). The traditional PPP algorithm requires precise satellite products based on worldwide permanent reference stations. Such an algorithm requires considerable work and hardly achieves real-time performance. However, real-time positioning service will be the dominant mode in the future. IGS is providing such an operational service (RTS) and there are also commercial systems like Trimble RTX in operation. On the basis of the regional Continuous Operational Reference System (CORS), a real-time PPP algorithm is proposed to apply the coupling estimation of clock bias and orbit error. The projection of orbit error onto the satellite-receiver range has the same effects on positioning accuracy with clock bias. Therefore, in satellite clock estimation, part of the orbit error can be absorbed by the clock bias and the effects of residual orbit error on positioning accuracy can be weakened by the evenly distributed satellite geometry. In consideration of the simple structure of pseudorange equations and the high precision of carrier-phase equations, the clock bias estimation method coupled with orbit error is also improved. Rovers obtain PPP results by receiving broadcast ephemeris and real-time satellite clock bias coupled with orbit error. By applying the proposed algorithm, the precise orbit products provided by GNSS analysis centers are rendered no longer necessary. On the basis of previous theoretical analysis, a real-time PPP system was developed. Some experiments were then designed to verify this algorithm. Experimental results show that the newly proposed approach performs better than the traditional PPP based on International GNSS Service (IGS) real-time products. The positioning accuracies of the rovers inside and outside the network are improved by 38.8% and 36.1%, respectively. The PPP convergence speeds are improved by up to 61.4% and 65.9%. The new approach can change the traditional PPP mode because of its advantages of independence, high positioning precision, and real-time performance. It could be an alternative solution for regional positioning service before global PPP service comes into operation.
Pan, Shuguo; Chen, Weirong; Jin, Xiaodong; Shi, Xiaofei; He, Fan
2015-01-01
Satellite orbit error and clock bias are the keys to precise point positioning (PPP). The traditional PPP algorithm requires precise satellite products based on worldwide permanent reference stations. Such an algorithm requires considerable work and hardly achieves real-time performance. However, real-time positioning service will be the dominant mode in the future. IGS is providing such an operational service (RTS) and there are also commercial systems like Trimble RTX in operation. On the basis of the regional Continuous Operational Reference System (CORS), a real-time PPP algorithm is proposed to apply the coupling estimation of clock bias and orbit error. The projection of orbit error onto the satellite-receiver range has the same effects on positioning accuracy with clock bias. Therefore, in satellite clock estimation, part of the orbit error can be absorbed by the clock bias and the effects of residual orbit error on positioning accuracy can be weakened by the evenly distributed satellite geometry. In consideration of the simple structure of pseudorange equations and the high precision of carrier-phase equations, the clock bias estimation method coupled with orbit error is also improved. Rovers obtain PPP results by receiving broadcast ephemeris and real-time satellite clock bias coupled with orbit error. By applying the proposed algorithm, the precise orbit products provided by GNSS analysis centers are rendered no longer necessary. On the basis of previous theoretical analysis, a real-time PPP system was developed. Some experiments were then designed to verify this algorithm. Experimental results show that the newly proposed approach performs better than the traditional PPP based on International GNSS Service (IGS) real-time products. The positioning accuracies of the rovers inside and outside the network are improved by 38.8% and 36.1%, respectively. The PPP convergence speeds are improved by up to 61.4% and 65.9%. The new approach can change the traditional PPP mode because of its advantages of independence, high positioning precision, and real-time performance. It could be an alternative solution for regional positioning service before global PPP service comes into operation. PMID:26205276
Gnss Geodetic Monitoring as Support of Geodynamics Research in Colombia, South America
NASA Astrophysics Data System (ADS)
Mora-Paez, H.; Acero-Patino, N.; Rodriguez-Zuluaga, J. S.; Diederix, H.; Bohorquez-Orozco, O. P.; Martinez-Diaz, G. P.; Diaz-Mila, F.; Giraldo-Londono, L. S.; Cardozo-Giraldo, S.; Vasquez-Ospina, A. F.; Lizarazo, S. C.
2013-05-01
To support the geodynamics research at the northwestern corner of South America, GEORED, the acronym for "Geodesia: Red de Estudios de Deformación" has been adopted for the Project "Implementation of the National GNSS Network for Geodynamics" carried out by the Colombian Geological Survey, (SGC), formerly INGEOMINAS. Beginning in 2007, discussions within the GEORED group led to a master plan for the distribution of the base permanent GPS/GNSS station array and specific areas of interest for campaign site construction. The use of previously identified active faults as preferred structures along which stresses are transferred through the deformational area led to the idea of segmentation of the North Andes within Colombia into 20 tectonic sub-blocks. Each of the 20 sub-blocks is expected to have, at least, three-four permanent GPS/GNSS stations within the block along with construction of campaign sites along the boundaries. Currently, the GEORED Network is managing 46 continuously including: 40 GEORED GPS/GNSS continuously operating stations; 4 GNSS continuously operating stations provided by the COCONet (Continuously Operating Caribbean GPS Observational Network) Project; the Bogotá IGS GPS station (BOGT), installed in 1994 under the agreement between JPL-NASA and the SGC; and the San Andres Island station, installed in 2007 under the MOU between UCAR and the SGC. In addition to the permanent installations, more than 230 GPS campaign sites have been constructed and are being occupied one time per year. The Authority of the Panama Canal and the Escuela Politecnica de Quito have also provided data of 4 and 5 GPS/GNSS stations respectively. The GPS data are processed using the GIPSY-OASIS II software, and the GPS time series of daily station positions give fundamental information for both regional and local geodynamics studies. Until now, we have obtained 100 quality vector velocities for Colombia, 23 of them as part of the permanent network. The GPS/GNSS stations are located on the three major plates that interact within the Wide Plate Margin Deformation Zone including existing permanent installations on IGS Galapagos and Malpelo Islands on the Nazca Plate, and San Andres Island on the Caribbean plate. The velocity vectors confirm the oblique subduction of the Nazca Plate and Carnegie aseismic ridge collision processes at the Colombia-Ecuador trench which are assumed to be the mechanism for the transpressional deformation and the "escape" of the North Andes Block (NAB). The northernmost vectors in Colombia are indicative of the ongoing collision of the Panama Arc with northwestern Colombia. Planned for the year 2013 is the installation of 10 additional GNSS continuously operating stations, and construction of 20 GPS campaign sites.
Subdaily alias and draconitic errors in the IGS orbits
NASA Astrophysics Data System (ADS)
Griffiths, J.; Ray, J.
2011-12-01
Harmonic signals with a fundamental period near the GPS draconitic year (351.2 d) and overtones up to the 8th multiple have been observed in the power spectra of nearly all products of the International GNSS Service (IGS), including station position time series [Ray et al., 2008; Collilieux et al., 2007; Santamaría-Gómez et al., 2011], apparent geocenter motions [Hugentobler et al., 2008], and orbit jumps between successive days and midnight discontinuities in Earth orientation parameter (EOP) rates [Ray and Griffiths, 2009]. Ray et al. [2008] suggested two mechanisms for the harmonics: mismodeling of orbit dynamics and aliasing of near-sidereal local station multipath effects. King and Watson [2010] have studied the propagation of local multipath errors into draconitic position variations, but orbit-related processes have been less well examined. Here we elaborate our earlier analysis of GPS orbit jumps [Griffiths and Ray, 2009; Gendt et al., 2010] where we observed some draconitic features as well as prominent spectral bands near 29, 14, 9, and 7 d periods. Finer structures within the sub-seasonal bands fall close to the expected alias frequencies of subdaily EOP tide lines but do not coincide precisely. While once-per-rev empirical orbit parameters should strongly absorb any subdaily EOP tide errors due to near-resonance of their respective periods, the observed differences require explanation. This has been done by simulating known EOP tidal errors and checking their impact on a long series of daily GPS orbits. Indeed, simulated tidal aliases are found to be very similar to the observed orbital features in the sub-seasonal bands. Moreover and unexpectedly, some low draconitic harmonics were also stimulated, potentially a source for the widespread errors in most IGS products.
Galileo satellite antenna modeling
NASA Astrophysics Data System (ADS)
Steigenberger, Peter; Dach, Rolf; Prange, Lars; Montenbruck, Oliver
2015-04-01
The space segment of the European satellite navigation system Galileo currently consists of six satellites. Four of them belong to the first generation of In-Orbit Validation (IOV) satellites whereas the other two are Full Operational Capability (FOC) satellites. High-precision geodetic applications require detailed knowledge about the actual phase center of the satellite and receiver antenna. The deviation of this actual phase center from a well-defined reference point is described by phase center offsets (PCOs) and phase center variations (PCVs). Unfortunately, no public information is available about the Galileo satellite antenna PCOs and PCVs, neither for the IOV, nor the FOC satellites. Therefore, conventional values for the IOV satellite antenna PCOs have been adopted for the Multi-GNSS experiment (MGEX) of the International GNSS Service (IGS). The effect of the PCVs is currently neglected and no PCOs for the FOC satellites are available yet. To overcome this deficiency in GNSS observation modeling, satellite antenna PCOs and PCVs are estimated for the Galileo IOV satellites based on global GNSS tracking data of the MGEX network and additional stations of the legacy IGS network. Two completely independent solutions are computed with the Bernese and Napeos software packages. The PCO and PCV values of the individual satellites are analyzed and the availability of two different solutions allows for an accuracy assessment. The FOC satellites are built by a different manufacturer and are also equipped with another type of antenna panel compared to the IOV satellites. Signal transmission of the first FOC satellite has started in December 2014 and activation of the second satellite is expected for early 2015. Based on the available observations PCO estimates and, optionally PCVs of the FOC satellites will be presented as well. Finally, the impact of the new antenna model on the precision and accuracy of the Galileo orbit determination is analyzed.
Performance Analysis of Several GPS/Galileo Precise Point Positioning Models
Afifi, Akram; El-Rabbany, Ahmed
2015-01-01
This paper examines the performance of several precise point positioning (PPP) models, which combine dual-frequency GPS/Galileo observations in the un-differenced and between-satellite single-difference (BSSD) modes. These include the traditional un-differenced model, the decoupled clock model, the semi-decoupled clock model, and the between-satellite single-difference model. We take advantage of the IGS-MGEX network products to correct for the satellite differential code biases and the orbital and satellite clock errors. Natural Resources Canada’s GPSPace PPP software is modified to handle the various GPS/Galileo PPP models. A total of six data sets of GPS and Galileo observations at six IGS stations are processed to examine the performance of the various PPP models. It is shown that the traditional un-differenced GPS/Galileo PPP model, the GPS decoupled clock model, and the semi-decoupled clock GPS/Galileo PPP model improve the convergence time by about 25% in comparison with the un-differenced GPS-only model. In addition, the semi-decoupled GPS/Galileo PPP model improves the solution precision by about 25% compared to the traditional un-differenced GPS/Galileo PPP model. Moreover, the BSSD GPS/Galileo PPP model improves the solution convergence time by about 50%, in comparison with the un-differenced GPS PPP model, regardless of the type of BSSD combination used. As well, the BSSD model improves the precision of the estimated parameters by about 50% and 25% when the loose and the tight combinations are used, respectively, in comparison with the un-differenced GPS-only model. Comparable results are obtained through the tight combination when either a GPS or a Galileo satellite is selected as a reference. PMID:26102495
Nutation determination using the Global Positioning System
NASA Astrophysics Data System (ADS)
Yao, Kunliang; Capitaine, Nicole; Umnig, Elke; Weber, Robert
2012-08-01
VLBI observation of extragalactic radio sources is the only technique that allows high accuracy determination of nutation on a regular basis. However, this is limited to periods of nutation greater than about 30 days due to the current resolution of VL BI estimation. It is there fore important to use another technique to improve nutation at shorter periods. It has been shown by Rothacher et al. (1999) and Weber & Rothacher (2001) that GPS is a potential technique for the determination of the short period terms of nutation. The met hod, which is based on the estimation of nutation rates with respect to an a priori model, is limited to nutation terms in the higher frequency range (with periods up to about 21 days) due to deficiencies in the modeling of the satellite orbits. The high accuracy and high time resolution of the GPS observations that are now achieved give us the possibility to estimate the nutation variations with respect to the IAU2000A nutation, with an expected precision of 10 microarcseconds (μas ). The purpose of our study is to use recent GPS observations obtained by 140 IGS stations (IGS08 Core Reference Frame sites included) to estimate the short period nutations. Two methods are applied: one is to investigate the retrograde diurnal term of polar motion with nutation fixed to the IAU 2006/2000 precession - nutation, using CNES/GRGS software GINS/DYNAMO at Observatoire de Paris; another one is to investigate the nutation time derivative, with polar motion fixed, using Bernese GPS software at University of Technology in Vienna. In this poster, we report on our preliminary results with data set covering a period of 3 years (2009 - 2011), with appropriate time resolutions and on the comparison between the two approaches.
Performance Analysis of Several GPS/Galileo Precise Point Positioning Models.
Afifi, Akram; El-Rabbany, Ahmed
2015-06-19
This paper examines the performance of several precise point positioning (PPP) models, which combine dual-frequency GPS/Galileo observations in the un-differenced and between-satellite single-difference (BSSD) modes. These include the traditional un-differenced model, the decoupled clock model, the semi-decoupled clock model, and the between-satellite single-difference model. We take advantage of the IGS-MGEX network products to correct for the satellite differential code biases and the orbital and satellite clock errors. Natural Resources Canada's GPSPace PPP software is modified to handle the various GPS/Galileo PPP models. A total of six data sets of GPS and Galileo observations at six IGS stations are processed to examine the performance of the various PPP models. It is shown that the traditional un-differenced GPS/Galileo PPP model, the GPS decoupled clock model, and the semi-decoupled clock GPS/Galileo PPP model improve the convergence time by about 25% in comparison with the un-differenced GPS-only model. In addition, the semi-decoupled GPS/Galileo PPP model improves the solution precision by about 25% compared to the traditional un-differenced GPS/Galileo PPP model. Moreover, the BSSD GPS/Galileo PPP model improves the solution convergence time by about 50%, in comparison with the un-differenced GPS PPP model, regardless of the type of BSSD combination used. As well, the BSSD model improves the precision of the estimated parameters by about 50% and 25% when the loose and the tight combinations are used, respectively, in comparison with the un-differenced GPS-only model. Comparable results are obtained through the tight combination when either a GPS or a Galileo satellite is selected as a reference.
Koprivica, Mladen; Slavkovic, Vladimir; Neskovic, Natasa; Neskovic, Aleksandar
2016-03-01
As a result of dense deployment of public mobile base stations, additional electromagnetic (EM) radiation occurs in the modern human environment. At the same time, public concern about the exposure to EM radiation emitted by such sources has increased. In order to determine the level of radio frequency radiation generated by base stations, extensive EM field strength measurements were carried out for 664 base station locations, from which 276 locations refer to the case of base stations with antenna system installed on buildings. Having in mind the large percentage (42 %) of locations with installations on buildings, as well as the inevitable presence of people in their vicinity, a detailed analysis of this location category was performed. Measurement results showed that the maximum recorded value of total electric field strength has exceeded International Commission on Non-Ionizing Radiation Protection general public exposure reference levels at 2.5 % of locations and Serbian national reference levels at 15.6 % of locations. It should be emphasised that the values exceeding the reference levels were observed only outdoor, while in indoor total electric field strength in no case exceeded the defined reference levels. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Wulfert, F; Sanyasi, G; Tongen, L; Watanabe, L A; Wang, X; Renault, N K; Falcone, F H; Jacob, C M A; Alcocer, M J C
2012-08-31
The sera of a retrospective cohort (n=41) composed of children with well characterized cow's milk allergy collected from multiple visits were analyzed using a protein microarray system measuring four classes of immunoglobulins. The frequency of the visits, age and gender distribution reflected real situation faced by the clinicians at a pediatric reference center for food allergy in São Paulo, Brazil. The profiling array results have shown that total IgG and IgA share similar specificity whilst IgM and in particular IgE are distantly related. The correlation of specificity of IgE and IgA is variable amongst the patients and this relationship cannot be used to predict atopy or the onset of tolerance to milk. The array profiling technique has corroborated the clinical selection criteria for this cohort albeit it clearly suggested that 4 out of the 41 patients might have allergies other than milk origin. There was also a good correlation between the array data and ImmunoCAP results, casein in particular. By using qualitative and quantitative multivariate analysis routines it was possible to produce validated statistical models to predict with reasonable accuracy the onset of tolerance to milk proteins. If expanded to larger study groups, the array profiling in combination with the multivariate techniques show potential to improve the prognostic of milk allergic patients. Copyright © 2012 Elsevier B.V. All rights reserved.
GPS-Only Terrestrial Reference Frame Based on a Global Reprocessing
NASA Astrophysics Data System (ADS)
Dietrich, R.; Rothacher, M.; Ruelke, A.; Fritsche, M.; Steigenberger, P.
2007-12-01
The realization of the International Terrestrial Reference System (ITRS) with highest accuracy and stability is fundamental and crucial for applications in geodesy, geodynamics, geophysics and global change. In a joint effort TU Dresden and TU Munich/GFZ Potsdam reprocessed a global GPS network of more than 200 stations. As a contribution to an ITRS realization daily normal equations from 1994 to 2005 were rigorously combined in order to determine a global GPS-only reference frame (PDR05/Potsdam-Dresden-Reprocessing Reference Frame). We present a realization of the global terrestrial reference system which follows the center of mass approach in consideration of the load-induced deformation of the Earth's crust due to the redistribution of surface masses. The stability of our reference frame will be evaluated based on the obtained long-term trends of station coordinates, the load-induced deformation estimates and the homogeneous time series of station positions. We will compare our solution with other recent terrestrial reference system realizations and give some conclusions for future realizations of the ITRS.
Standardization of Assays That Detect Anti-Rubella Virus IgG Antibodies
Grangeot-Keros, Liliane; Vauloup-Fellous, Christelle
2015-01-01
SUMMARY Rubella virus usually causes a mild infection in humans but can cause congenital rubella syndrome (CRS). Vaccination programs have significantly decreased primary rubella virus infection and CRS; however, vaccinated individuals usually have lower levels of rubella virus IgG than those with natural infections. Rubella virus IgG is quantified with enzyme immunoassays that have been calibrated against the World Health Organization (WHO) international standard and report results in international units per milliliter. It is recognized that the results reported by these assays are not standardized. This investigation into the reasons for the lack of standardization found that the current WHO international standard (RUB-1-94) fails by three key metrological principles. The standard is not a pure analyte but is composed of pooled human immunoglobulin. It was not calibrated by certified reference methods; rather, superseded tests were used. Finally, no measurement uncertainty estimations have been provided. There is an analytical and clinical consequence to the lack of standardization of rubella virus IgG assays, which leads to misinterpretation of results. The current approach to standardization of rubella virus IgG assays has not achieved the desired results. A new approach is required. PMID:26607813
Current Concepts and Diagnosis of IgG4-Related Pancreatitis (Type 1 AIP).
Kawa, Shigeyuki
2016-08-01
Although now considered to be a member of the systemic entity of immunoglobulin G4- (IgG4-) related disease, IgG4-related pancreatitis is generally referred to as type 1 autoimmune pancreatitis (AIP). Type 1 AIP was established based on a pathological background of lymphoplasmacytic sclerosing pancreatitis, high serum IgG4 concentration, and abundant IgG4-bearing plasma cell infiltration. The characteristic clinical features of type 1 AIP, such as elderly male preponderance, obstructive jaundice, and mass-forming lesions in the pancreas, often mimic those of pancreatic cancer. However, because AIP responds favorably to corticosteroid treatment, careful differentiation from pancreatic cancer is required. An AIP diagnosis is currently based on the 2011 International Consensus Diagnostic Criteria for AIP, which are based on high sensitivity, selectivity, and accuracy. Over the long term, AIP can progress to a chronic condition, with pancreatic stone formation and atrophy resembling that of chronic pancreatitis. Although AIP has been linked to the complication of malignancies, it remains controversial whether an association exists between the disease and tumor formation. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Sankar, Surya; Harshan, Hiron M; Somarajan, S R; Srivastava, S K
2010-06-01
A recombinant leptospiral lipoprotein, LigB, was evaluated for use in the diagnosis of bovine leptospirosis by enzyme-linked immunosorbent assay (rLigB IgG ELISA). The standard reference test (Microscopic agglutination test, MAT) of 200 serum samples from cattle suspected of leptospirosis showed that 95 (47.5%) samples had positive agglutination titres, which ranged from 100 to 1600. In rLigB IgG ELISA, 49% of the samples were positive. Sensitivity of IgG ELISA for 95 bovine sera, which had MAT titres of greater than or equal to 100, were 100%. ELISA showed a specificity of 97.1% with 105 bovine sera, which were negative at a 1:50 dilution in MAT for Leptospira interrogans serovars. The results of ELISA and MAT correspond very good. When analytical specificity of IgG ELISA was evaluated using bovine serum samples from animals showing the serum antibodies to other pathogens, no cross-reaction was observed. Thus the recombinant LigB IgG ELISA can be used instead of the MAT as an aid to the diagnosis of bovine leptospirosis. Copyright 2009. Published by Elsevier India Pvt Ltd.
Hedman, Lea; Dhanilall, Pravesh; Kantola, Kalle; Nurmi, Visa; Söderlund-Venermo, Maria; Brown, Kevin E.; Hedman, Klaus
2014-01-01
Parvovirus B19 (B19V) is a member of the family Parvoviridae, genus Erythrovirus. B19V-specific IgG and IgM react differently against conformational and linear epitopes of VP1 and VP2 antigens, leading to the development of IgG avidity and epitope type specificity (ETS) enzyme immunoassays (EIAs) for distinguishing past from recent infection. Additionally, B19V viral load determination (by quantitative PCR [qPCR]) is increasingly used in the staging of B19V infection. In this study, the utility of these methods is compared. A panel of 78 sera was jointly tested by the Virus Reference Department (VRD), London, United Kingdom, and the Haartman Institute (HI), Helsinki, Finland, using a number of EIAs, e.g., B19V-specific IgG and IgM, IgG avidity, and ETS EIAs. At VRD, the sera were also tested by a B19V viral load PCR (qPCR). By consensus analysis, 43 (55.1%) sera represented past infection, 28 (35.9%) sera represented recent infection, and 7 (9.0%) sera were indeterminate. Both VRD B19V qPCR and HI B19V VP2 IgM EIA gave the highest agreement with consensus interpretation for past or recent infection, with an overall agreement of 99% (95% confidence interval [CI], 92 to 100) and positive predictive value (PPV) of 100% (95% CI, 87 to 100). Nine sera designated as representing past infection by consensus analysis were B19V IgM positive by a commercial VRD B19V IgM EIA and B19V IgM negative by a new HI in-house B19V VP2 IgM EIA. A new VRD B19V IgG avidity EIA showed good (>95%) agreement (excluding equivocal results) with consensus interpretations for past or recent infection. Correct discrimination of past from recent B19V infection was achieved through application of qPCR or by appropriate selection of EIAs. PMID:24403307
Elsohaby, Ibrahim; Burns, Jennifer J.; Riley, Christopher B.; McClure, J. Trenton
2017-01-01
This study aimed to evaluate the digital Brix and optical serum total protein (STP) refractometers for measuring concentrations of serum immunoglobulin G (IgG) in alpacas and compare them to IgG concentrations measured by the reference method of radial immunodiffusion (RID) assay. The appropriate cutoff point for Brix and STP refractometers and the transmission infrared (TIR) spectroscopy method was determined for low IgG concentrations (< 10 g/L). Serum samples were collected from alpacas (N = 169) and tested by both refractometers. The correlation between Brix % and STP was high [correlation coefficient (r) = 0.99]. However, the correlation coefficients between Brix % and STP with serum RID-IgG concentrations were only 0.56 and 0.55, respectively. Twenty-one (12.4%) of 169 alpaca serum samples had IgG concentrations of < 10 g/L. Using receiver operator characteristic curve (ROC) analysis, the optimal cutoff points for the TIR assay, digital Brix, and optical STP refractometers for assessing low IgG (RID < 10 g/L) were 13 g/L, 8.8%, and 50 g/L, respectively. The TIR assay showed higher sensitivity (Se = 95.2%) and specificity (Sp = 96.8%) than either the digital Brix (Se = 90.5% and Sp = 65.5%) or optical STP (Se = 81% and Sp = 73.7%) refractometers for assessing alpacas with low IgG. In conclusion, the Brix and STP refractometers lack accuracy in measuring alpaca IgG concentrations, but may be useful for screening animals for low serum IgG. However, the TIR assay with a cutoff point of 13 g/L was more appropriate for identifying low IgG than either refractometer. Another study that focuses on neonatal crias is recommended in order to evaluate the usefulness of these assays for field diagnosing of failure of transfer of passive immunity (FTPI). PMID:28725112
Elsohaby, Ibrahim; Burns, Jennifer J; Riley, Christopher B; McClure, J Trenton
2017-07-01
This study aimed to evaluate the digital Brix and optical serum total protein (STP) refractometers for measuring concentrations of serum immunoglobulin G (IgG) in alpacas and compare them to IgG concentrations measured by the reference method of radial immunodiffusion (RID) assay. The appropriate cutoff point for Brix and STP refractometers and the transmission infrared (TIR) spectroscopy method was determined for low IgG concentrations (< 10 g/L). Serum samples were collected from alpacas (N = 169) and tested by both refractometers. The correlation between Brix % and STP was high [correlation coefficient (r) = 0.99]. However, the correlation coefficients between Brix % and STP with serum RID-IgG concentrations were only 0.56 and 0.55, respectively. Twenty-one (12.4%) of 169 alpaca serum samples had IgG concentrations of < 10 g/L. Using receiver operator characteristic curve (ROC) analysis, the optimal cutoff points for the TIR assay, digital Brix, and optical STP refractometers for assessing low IgG (RID < 10 g/L) were 13 g/L, 8.8%, and 50 g/L, respectively. The TIR assay showed higher sensitivity (Se = 95.2%) and specificity (Sp = 96.8%) than either the digital Brix (Se = 90.5% and Sp = 65.5%) or optical STP (Se = 81% and Sp = 73.7%) refractometers for assessing alpacas with low IgG. In conclusion, the Brix and STP refractometers lack accuracy in measuring alpaca IgG concentrations, but may be useful for screening animals for low serum IgG. However, the TIR assay with a cutoff point of 13 g/L was more appropriate for identifying low IgG than either refractometer. Another study that focuses on neonatal crias is recommended in order to evaluate the usefulness of these assays for field diagnosing of failure of transfer of passive immunity (FTPI).
Dauner, Allison L.; Valks, Andrea; Forshey, Brett M.; Long, Kanya C.; Thaisomboonsuk, Butsaya; Sierra, Gloria; Picos, Victor; Talmage, Sara; Morrison, Amy C.; Halsey, Eric S.; Comach, Guillermo; Yasuda, Chadwick; Loeffelholz, Michael; Jarman, Richard G.; Fernandez, Stefan; An, Ung Sam; Kochel, Tadeusz J.; Jasper, Louis E.; Wu, Shuenn-Jue L.
2015-01-01
We evaluated four dengue diagnostic devices from Alere, including the SD Bioline Dengue Duo (nonstructural [NS] 1 Ag and IgG/IgM), the Panbio Dengue Duo Cassette (IgM/IgG) rapid diagnostic tests (RDTs), and the Panbio dengue IgM and IgG capture enzyme-linked immunosorbent assays (ELISAs) in a prospective, controlled, multicenter study in Peru, Venezuela, Cambodia, and the United States, using samples from 1,021 febrile individuals. Archived, well-characterized samples from an additional 135 febrile individuals from Thailand were also used. Reference testing was performed on all samples using an algorithm involving virus isolation, in-house IgM and IgG capture ELISAs, and plaque reduction neutralization tests (PRNT) to determine the infection status of the individual. The primary endpoints were the clinical sensitivities and specificities of these devices. The SD Bioline Dengue Duo had an overall sensitivity of 87.3% (95% confidence interval [CI], 84.1 to 90.2%) and specificity of 86.8% (95% CI, 83.9 to 89.3%) during the first 14 days post-symptom onset (p.s.o.). The Panbio Dengue Duo Cassette demonstrated a sensitivity of 92.1% (87.8 to 95.2%) and specificity of 62.2% (54.5 to 69.5%) during days 4 to 14 p.s.o. The Panbio IgM capture ELISA had a sensitivity of 87.6% (82.7 to 91.4%) and specificity of 88.1% (82.2 to 92.6%) during days 4 to 14 p.s.o. Finally, the Panbio IgG capture ELISA had a sensitivity of 69.6% (62.1 to 76.4%) and a specificity of 88.4% (82.6 to 92.8%) during days 4 to 14 p.s.o. for identification of secondary dengue infections. This multicountry prospective study resulted in reliable real-world performance data that will facilitate data-driven laboratory test choices for managing patient care during dengue outbreaks. PMID:25588659
NASA Astrophysics Data System (ADS)
Lander, D. M. P.; McCanty, S. T.; Dimino, T. F.; Christian, A. D.
2016-02-01
The River Continuum Concept (RCC) predicts stream biological communities based on dominant physical structures and energy inputs into streams and predicts how these features and corresponding communities change along the stream continuum. Verifying RCC expectations is important for creating valid points of comparison during stream ecosystem evaluation. These reference expectations are critical for restoration projects, such as the restoration of decommissioned cranberry bogs. Our research compares the physical habitat and freshwater invertebrate functional feeding groups (FWIFFG) of reference, active cranberry farming, and cranberry farm passive restoration sites in Northeastern Coastal Zone streams of Massachusetts to the specific RCC FWIFFG predictions. We characterized stream physical habitat using a semi-quantitative habitat characterization protocol and sampled freshwater invertebrates using the U.S. EPA standard 20-jab multi-habitat protocol. We expected that stream habitat would be most homogeneous at active farming stations, intermediate at restoration stations, and most heterogeneous at reference stations. Furthermore, we expected reference stream FWIFFG would be accurately predicted by the RCC and distributions at restoration and active sites would vary significantly. Habitat data was analyzed using a principle component analysis and results confirmed our predictions showing more homogeneous habitat for the active and reference stations, while showing a more heterogeneous habitat at the reference stations. The FWIFFG chi-squared analysis showed significant deviation from our specific RCC FWIFFG predictions. Because published FWIFFG distributions did not match our empirical values for a least disturbed Northeastern Coastal Zone headwater stream, using our data as a community structure template for current and future restoration projects is not recommend without further considerations.
Werwitzke, S; Geisen, U; Nowak-Göttl, U; Eichler, H; Stephan, B; Scholz, U; Holstein, K; Klamroth, R; Knöbl, P; Huth-Kühne, A; Bomke, B; Tiede, A
2016-05-01
Essentials Factor VIII (FVIII) binding IgG detected by ELISA could be an alternative to the Bethesda assay. We studied the performance of anti-FVIII IgG ELISA in patients with acquired hemophilia and controls. Anti-FVIII IgG > 99th percentile of controls was highly sensitive and specific. Patients with high anti-FVIII IgG have a lower chance of achieving remission. Background Acquired hemophilia A is a severe bleeding disorder that requires fast and accurate diagnosis as it occurs often unexpectedly in previously healthy men and women of every age. The Nijmegen-modified Bethesda assay is the diagnostic reference standard for detecting neutralizing autoantibodies against factor VIII (FVIII), but is not widely available, not ideal for quantifying the complex type 2 inhibitors seen in acquired hemophilia, and suffers from high inter-laboratory variability. Objectives To assess the diagnostic and prognostic value of FVIII-binding antibodies as detected by ELISA compared with the Nijmegen Bethesda assay. Methods Samples from the time of first diagnosis and clinical data were available from 102 patients with acquired hemophilia enrolled in the prospective GTH-AH 01/2010 study. Controls (n = 102) were matched for gender and age. Diagnostic cut-offs were determined by receiver-operator curve analysis. The prognostic value was assessed in 92 of the 102 patients by Cox regression analysis of time to partial remission. Results Anti-FVIII IgG above the 99th percentile (> 15 arbitrary units per mL) revealed high sensitivity and specificity (both 0.99; 95% confidence interval, 0.95-1.0) for diagnosing acquired hemophilia. The likelihood of achieving partial remission was related to anti-FVIII IgG concentration (< 300 arbitrary units, 1.0; 300-1050, 0.65; > 1050, 0.39). The Bethesda titer was only associated with the likelihood of partial remission when analyzed in the central laboratory, but not when data from local GTH study sites were used. Conclusion Although the Nijmegen-modified Bethesda assay is the reference standard for demonstrating neutralizing antibodies, the detection of FVIII-binding antibodies by ELISA is similarly sensitive and specific for diagnosing acquired hemophilia. In addition, anti-FVIII IgG may provide prognostic information. © 2016 International Society on Thrombosis and Haemostasis.
NASA Astrophysics Data System (ADS)
Ruiz, M. C.; Yepes, H. A.; Hall, M. L.; Mothes, P. A.; Ramon, P.; Hidalgo, S.; Andrade, D.; Vallejo Vargas, S.; Steele, A. L.; Anzieta, J. C.; Ortiz, H. D.; Palacios, P.; Alvarado, A. P.; Enriquez, W.; Vasconez, F.; Vaca, M.; Arrais, S.; Viracucha, G.; Bernard, B.
2014-12-01
In 1988, the Instituto Geofisico (IG) began a permanent surveillance of Ecuadorian volcanoes, and due to activity on Guagua Pichincha, SP seismic stations and EDM control lines were then installed. Later, with the UNDRO and OAS projects, telemetered seismic monitoring was expanded to Tungurahua, Cotopaxi, Cuicocha, Chimborazo, Antisana, Cayambe, Cerro Negro, and Quilotoa volcanoes. In 1992 an agreement with the Instituto Ecuatoriano de Electrificacion strengthened the monitoring of Tungurahua and Cotopaxi volcanoes with real-time SP seismic networks and EDM lines. Thus, background activity levels became established, which was helpful because of the onset of the 1999 eruptive activity at Tungurahua and Guagua Pichincha. These eruptions had a notable impact on Baños and Quito. Unrest at Cotopaxi volcano was detected in 2001-2002, but waned. In 2002 Reventador began its eruptive period which continues to the present and is closely monitored by the IG. In 2006 permanent seismic BB stations and infrasound sensors were installed at Tungurahua and Cotopaxi under a cooperative program supported by JICA, which allowed us to follow Tungurahua's climatic eruptions of 2006 and subsequent eruptions up to the present. Programs supported by the Ecuadorian Secretaria Nacional de Ciencia y Tecnologia and the Secretaria Nacional de Planificacion resulted in further expansion of the IG's monitoring infrastructure. Thermal and video imagery, SO2 emission monitoring, geochemical analyses, continuous GPS and tiltmeters, and micro-barometric surveillance have been incorporated. Sangay, Soche, Ninahuilca, Pululahua, and Fernandina, Cerro Azul, Sierra Negra, and Alcedo in the Galapagos Islands are now monitored in real-time. During this time, international cooperation with universities (Blaise Pascal & Nice-France, U. North Carolina, New Mexico Tech, Uppsala-Sweden, Nagoya, etc.), and research centers (USGS & UNAVCO-USA, IRD-France, NIED-Japan, SGC-Colombia, VAAC, MIROVA) has introduced the use of new technologies and methods. An agreement with the Secretaria de Gestion de Riesgos fortifies the communication flow to society, officials, and risk managers. Today the IG has the challenge of offering real-time information through a web-based net of virtual observatories.
Real-Time Tropospheric Delay Estimation using IGS Products
NASA Astrophysics Data System (ADS)
Stürze, Andrea; Liu, Sha; Söhne, Wolfgang
2014-05-01
The Federal Agency for Cartography and Geodesy (BKG) routinely provides zenith tropospheric delay (ZTD) parameter for the assimilation in numerical weather models since more than 10 years. Up to now the results flowing into the EUREF Permanent Network (EPN) or E-GVAP (EUMETNET EIG GNSS water vapour programme) analysis are based on batch processing of GPS+GLONASS observations in differential network mode. For the recently started COST Action ES1206 about "Advanced Global Navigation Satellite Systems tropospheric products for monitoring severe weather events and climate" (GNSS4SWEC), however, rapid updates in the analysis of the atmospheric state for nowcasting applications require changing the processing strategy towards real-time. In the RTCM SC104 (Radio Technical Commission for Maritime Services, Special Committee 104) a format combining the advantages of Precise Point Positioning (PPP) and Real-Time Kinematic (RTK) is under development. The so-called State Space Representation approach is defining corrections, which will be transferred in real-time to the user e.g. via NTRIP (Network Transport of RTCM via Internet Protocol). Meanwhile messages for precise orbits, satellite clocks and code biases compatible to the basic PPP mode using IGS products are defined. Consequently, the IGS Real-Time Service (RTS) was launched in 2013 in order to extend the well-known precise orbit and clock products by a real-time component. Further messages e.g. with respect to ionosphere or phase biases are foreseen. Depending on the level of refinement, so different accuracies up to the RTK level shall be reachable. In co-operation of BKG and the Technical University of Darmstadt the real-time software GEMon (GREF EUREF Monitoring) is under development. GEMon is able to process GPS and GLONASS observation and RTS product data streams in PPP mode. Furthermore, several state-of-the-art troposphere models, for example based on numerical weather prediction data, are implemented. Hence, it opens the possibility to evaluate the potential of troposphere parameter determination in real-time and its effect to Precise Point Positioning. Starting with an offline investigation of the influence of different RTS products and a priori troposphere models the configuration delivering the best results is used for a real-time processing of the GREF (German Geodetic Reference) network over a suitable period of time. The evaluation of the derived ZTD parameters and station heights is done with respect to well proven GREF, EUREF, IGS, and E-GVAP analysis results. Keywords: GNSS, Zenith Tropospheric Delay, Real-time Precise Point Positioning
Yergeau, Etienne; Maynard, Christine; Sanschagrin, Sylvie; Champagne, Julie; Juck, David; Lee, Kenneth
2015-01-01
Several studies have assessed the effects of the released oil on microbes, either during or immediately after the Deepwater Horizon accident. However, little is known about the potential longer-term persistent effects on microbial communities and their functions. In this study, one water column station near the wellhead (3.78 km southwest of the wellhead), one water column reference station outside the affected area (37.77 km southeast of the wellhead), and deep-sea sediments near the wellhead (3.66 km southeast of the wellhead) were sampled 1 year after the capping of the well. In order to analyze microbial community composition, function, and activity, we used metagenomics, metatranscriptomics, and mineralization assays. Mineralization of hexadecane was significantly higher at the wellhead station at a depth of ∼1,200 m than at the reference station. Community composition based on taxonomical or functional data showed that the samples taken at a depth of ∼1,200 m were significantly more dissimilar between the stations than at other depths (surface, 100 m, 750 m, and >1,500 m). Both Bacteria and Archaea showed reduced activity at depths of ∼1,200 m when the wellhead station was compared to the reference station, and their activity was significantly higher in surficial sediments than in 10-cm sediments. Surficial sediments also harbored significantly different active genera than did 5- and 10-cm sediments. For the remaining microbial parameters assessed, no significant differences could be observed between the wellhead and reference stations and between surface and 5- to 10-cm-deep sediments. PMID:26092461
Pérez-Cano, Francisco J; Marín-Gallén, Silvia; Castell, Margarida; Rodríguez-Palmero, María; Rivero, Montserrat; Franch, Angels; Castellote, Cristina
2007-10-01
During neonatal life, challenges from breast milk and microbial flora promote immune system maturation. Immunonutrition in these stages may become an important way to increase natural defence systems. The aim of this study was to determine the effect of a daily bovine milk whey protein concentrate (WPC) supplement on the intestinal and systemic immune systems in suckling rats. The composition of intraepithelial and lamina propria lymphocytes (IEL and LPL) was analysed by flow cytometry. Systemic and intestinal humoral immune responses were determined by sera Ig levels and Ig-secreting cell quantification by ELISA and ELISPOT, respectively. From birth, suckling Wistar rats were supplemented with WPC or standard infant formula (SIF). The WPC group showed the same proportion of most of the main mucosal cell subsets as the reference animals. However, in the first days of life WPC enhanced the innate immunity by increasing the NK cell proportion in both epithelial and lamina propria (LP) compartments. A rise in intestinal CD8alphaalpha+ IEL was also induced by WPC supplementation. A time-course of sera Ig levels and spontaneous IgA, IgM and IgG production by LPL and mononuclear cells from blood and spleen, in the WPC group, exhibited a similar pattern to those pups fed only by dam's milk. In summary, the present results show the effects of WPC on enhancing mucosal innate immunity during early life.
Common View Time Transfer Using Worldwide GPS and DMA Monitor Stations
NASA Technical Reports Server (NTRS)
Reid, Wilson G.; McCaskill, Thomas B.; Oaks, Orville J.; Buisson, James A.; Warren, Hugh E.
1996-01-01
Analysis of the on-orbit Navstar clocks and the Global Positioning System (GPS) monitor station reference clocks is performed by the Naval Research Laboratory using both broadcast and postprocessed precise ephemerides. The precise ephemerides are produced by the Defense Mapping Agency (DMA) for each of the GPS space vehicles from pseudo-range measurements collected at five GPS and at five DMA monitor stations spaced around the world. Recently, DMA established an additional site co-located with the US Naval Observatory precise time site. The time reference for the new DMA site is the DoD Master Clock. Now, for the first time, it is possible to transfer time every 15 minutes via common view from the DoD Master Clock to the 11 GPS and DMA monitor stations. The estimated precision of a single common-view time transfer measurement taken over a 15-minute interval was between 1.4 and 2.7 nanoseconds. Using the measurements from all Navstar space vehicles in common view during the 15-minute interval, typically 3-7 space vehicles, improved the estimate of the precision to between 0.65 and 1.13 nanoseconds. The mean phase error obtained from closure of the time transfer around the world using the 11 monitor stations and the 25 space vehicle clocks over a period of 4 months had a magnitude of 31 picoseconds. Analysis of the low noise time transfer from the DoD Master Clock to each of the monitor stations yields not only the bias in the time of the reference clock, but also focuses attention on structure in the behaviour of the reference clock not previously seen. Furthermore, the time transfer provides a a uniformly sampled database of 15-minute measurements that make possible, for the first time, the direct and exhaustive computation of the frequency stability of the monitor station reference clocks. To lend perspective to the analysis, a summary is given of the discontinuities in phase and frequency that occurred in the reference clock at the Master Control Station during the period covered by the analysis.
Time course of total and food specific IgE antibodies (Rast Fx5) in the developing allergic child.
Kalach, Nicolas; Soulaines, Pascale; Guerin, Sylvie; de Boissieu, Delphine; Dupont, Christophe
2005-09-01
To analyze the evolution of total and food specific IgE (Rast Fx5) titers in the course of food allergy in children. 925 children, mean age 8.9 + 9.1 years (15 days-18 years), 455 girls and 470 boys, investigated for food allergy in year 1997, underwent serum samples assay for total IgE and of Rast Fx5, Cap System, Pharmacia & Upjohn Diagnostics AB, Uppsala, Sweden, a mix test detecting specific IgE to 6 major food allergens in children, cow's milk proteins (CMP), egg white, peanut, soy, wheat and fish and analyzed as a function of reference values by age. Total IgE titers increased significantly with age, r0.22, p0.0001. The percentage of children with a total IgE level above normal range first increased with age, from 10.3 % at 0-6 months, reaching 38.2 % at 1-2 years and peaking at 56.9% at 4-6 years, then leveled off, 48.1% at 8-12 years (ns vs 4-6 years) and 41.3% above 12 years (ns). Detectable Rast Fx5 increased in a parallel manner until age 4-6 years and then exhibited a progressive decrease from age 6-8 years, differing significantly from total IgE: 31.9% vs 52.9%, p0.01 (6-8 years), 32.2% vs 48.1%, p0.03 (8-12 years), 21.8% vs 41.3%, p0.05 (> 12 years). In these outpatient children investigated for food allergy, the increase with age of the percentage of high total IgE contrasted with the progressive decrease of Rast Fx5 from age 4-6 yr. This biological finding correlates timely with the clinical spontaneous decrease of food allergy in the developing child.
Chris Maple, P A; Gray, Jim; Brown, Kevin; Brown, David
2009-04-01
Infection by Varicella Zoster virus (VZV) during pregnancy has been associated with adverse foetal development and more severe disease in the mother. Accurate determination of VZV immunity in pregnant women exposed to VZV, with no history of chickenpox, guides therapeutic interventions. The accepted gold standard assay for the determination of immunity/protection against Varicella Zoster virus was for many years the fluorescent antibody to membrane antigen (FAMA) assay which is labour intensive and subjective. A validated alternative is the Merck glycoprotein EIA (Merck Sharp & Dohme Research Laboratories, West Point, PA, USA) which reports VZV IgG levels in enzyme units per ml (EU/ml) because an internal, non-international reference serum is used as calibrator. Comparison of different VZV IgG detection assays is hampered by a lack of an agreed cut-off in standardised units. A time resolved fluorescence immunoassay (TRFIA) for VZV IgG using British Standard VZV antibody has been developed and standardised. The limit of detection of VZV IgG by this assay was of the order 39-78mIU/ml. Following comparison with the Merck glycoprotein EIA and the application of the USA Advisory Committee on Immunization Practices recommended 5.0EU/ml cut-off the following standardised cut-offs in mIU/ml are proposed. A VZV TRFIA IgG cut-off of less than 100mIU/ml VZV IgG equates with susceptibility and an equivocal range of 100mIU/ml to less than 150mIU/ml is proposed. VZV IgG levels of 150mIU/ml, or greater, are indicative of natural infection at some time and the ability to mount a protective immune response is inferred.
Kontis, Kris J; Valcour, Andre; Patel, Ashok; Chen, Andy; Wang, Jan; Chow, Julia; Nayak, Narayan
2006-01-01
It has been reported that in vitro measurement of food-specific IgE can be used to accurately predict food allergy and reduce the risk associated with double-blinded placebo-controlled food challenges (DBPCFC). Our objective was to assess the performance characteristics of the Hycor Turbo-MP quantitative radioimmunoassay for food-specific IgE and to determine this method's comparability to another assay, the Pharmacia ImmunoCAP fluorescence enzyme immunoassay (FEIA). The dynamic range of the Turbo-MP assay is 0.05 to 100 IU/ml, compared to 0.35 to 100 IU/ml for the FEIA. Performance characteristics of the Turbo-MP assay (ie, reproducibility of the calibration curve, within-run precision, total precision, parallelism, and linearity) were determined using samples from the Hycor serum bank. The precision (CV) of IgE calibrator replicates was <10%. The total precision (CV) of the Turbo-MP assay ranged from 8.8% to 18.4% for specific IgE concentrations between 0.28 to 31.4 IU/ml. Testing of serial dilutions of sera with IgE specificities for egg white, cow's milk, codfish, wheat, peanut, and soybean showed that the assay is linear over the entire dynamic range. Serial dilution data (slopes of 1.01 to 1.10) showed parallelism to serial dilutions of the IgE calibrator (slope of 0.96). The Turbo-MP and FEIA methods were both used for quantitative assays of food-specific IgE in 457 serum samples obtained from a clinical reference laboratory. Comparison of specific IgE results by the Turbo-MP and FEIA methods for 6 major food allergens exhibited a slope of 0.99 (0.92 to 1.03) with a correlation coefficient of 0.81.
Elsohaby, Ibrahim; McClure, J Trenton; Riley, Christopher B; Shaw, R Anthony; Keefe, Gregory P
2016-01-01
In this study, we evaluated and compared the performance of transmission and attenuated total reflectance (ATR) infrared (IR) spectroscopic methods (in combination with quantification algorithms previously developed using partial least squares regression) for the rapid measurement of bovine serum immunoglobulin G (IgG) concentration, and detection of failure of transfer of passive immunity (FTPI) in dairy calves. Serum samples (n = 200) were collected from Holstein calves 1-11 days of age. Serum IgG concentrations were measured by the reference method of radial immunodiffusion (RID) assay, transmission IR (TIR) and ATR-IR spectroscopy-based assays. The mean IgG concentration measured by RID was 17.22 g/L (SD ±9.60). The mean IgG concentrations predicted by TIR and ATR-IR spectroscopy methods were 15.60 g/L (SD ±8.15) and 15.94 g/L (SD ±8.66), respectively. RID IgG concentrations were positively correlated with IgG levels predicted by TIR (r = 0.94) and ATR-IR (r = 0.92). The correlation between 2 IR spectroscopic methods was 0.94. Using an IgG concentration <10 g/L as the cut-point for FTPI cases, the overall agreement between TIR and ATR-IR methods was 94%, with a corresponding kappa value of 0.84. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for identifying FTPI by TIR were 0.87, 0.97, 0.91, 0.95, and 0.94, respectively. Corresponding values for ATR-IR were 0.87, 0.95, 0.86, 0.95, and 0.93, respectively. Both TIR and ATR-IR spectroscopic approaches can be used for rapid quantification of IgG level in neonatal bovine serum and for diagnosis of FTPI in dairy calves. © 2015 The Author(s).
NASA Astrophysics Data System (ADS)
Wang, Kaihua; Chen, Hua; Jiang, Weiping; Li, Zhao; Ma, Yifang; Deng, Liansheng
2018-04-01
There are apparent seasonal variations in GPS height time series, and thermal expansion is considered to be one of the potential geophysical contributors. The displacements introduced by thermal expansion are usually derived without considering the annex height and underground part of the monument (e.g. located on roof or top of the buildings), which may bias the geophysical explanation of the seasonal oscillation. In this paper, the improved vertical displacements are derived by a refined thermal expansion model where the annex height and underground depth of the monument are taken into account, and then 560 IGS stations are adopted to validate the modeled thermal expansion (MTE) displacements. In order to evaluate the impact of thermal expansion on GPS heights, the MTE displacements of 80 IGS stations with less data discontinuities are selected to compare with their observed GPS vertical (OGV) displacements with the modeled surface loading (MSL) displacements removed in advance. Quantitative analysis results show the maximum annual and semiannual amplitudes of the MTE are 6.65 mm (NOVJ) and 0.51 mm (IISC), respectively, and the maximum peak-to-peak oscillation of the MTE displacements can be 19.4 mm. The average annual amplitude reductions are 0.75 mm and 1.05 mm respectively after removing the MTE and MSL displacements from the OGV, indicating the seasonal oscillation induced by thermal expansion is equivalent to >75% of the impact of surface loadings. However, there are rarely significant reductions for the semiannual amplitude. Given the result in this study that thermal expansion can explain 17.3% of the annual amplitude in GPS heights on average, it must be precisely modeled both in GPS precise data processing and GPS time series analysis, especially for those stations located in the middle and high latitudes with larger annual temperature oscillation, or stations with higher monument.
Evaluation of serum immunoglobulins among individuals living near six Superfund sites.
Williamson, Dhelia M; White, Mary C; Poole, Charles; Kleinbaum, David; Vogt, Robert; North, Kari
2006-07-01
Residents living in communities near Superfund sites have expressed concern that releases from these facilities affect their health, including adverse effects on their immune systems. We used data from six cross-sectional studies to evaluate whether people who live near several Superfund sites are more likely to have individual immunoglobulin test results (IgA, IgG, and IgM) below or above the reference range than those who live in comparison areas with no Superfund site. Study participants consisted of target-area residents who lived close to a Superfund site and comparison-area residents who were not located near any Superfund or hazardous waste sites. A consistent modeling strategy was used across studies to assess the magnitude of the relationship between area of residence and immunoglobulin test results, adjusting for potential confounders and effect modifiers. In all study areas, the results suggest that people who live near a Superfund site may have been more likely to have IgA test results above the reference range than comparison areas residents regardless of modeling strategy employed. The effect measures were larger for residents who lived in communities near military bases with groundwater contamination. For all analyses the wide confidence intervals reflect uncertainty in the magnitude of these effects. To adequately address the question of whether the immune system is affected by low-level exposures to hazardous substances, we recommend that more functional immunotoxicity tests be conducted in human populations where individual exposure information is available or when it can be reasonably estimated from environmental exposure measurements.
Kitashoji, Emi; Koizumi, Nobuo; Lacuesta, Talitha Lea V; Usuda, Daisuke; Ribo, Maricel R; Tria, Edith S; Go, Winston S; Kojiro, Maiko; Parry, Christopher M; Dimaano, Efren M; Villarama, Jose B; Ohnishi, Makoto; Suzuki, Motoi; Ariyoshi, Koya
2015-01-01
Leptospirosis is an important but largely under-recognized public health problem in the tropics. Establishment of highly sensitive and specific laboratory diagnosis is essential to reveal the magnitude of problem and to improve treatment. This study aimed to evaluate the diagnostic accuracy of a recombinant LigA protein based IgM ELISA during outbreaks in the clinical-setting of a highly endemic country. A prospective study was conducted from October 2011 to September 2013 at a national referral hospital for infectious diseases in Manila, Philippines. Patients who were hospitalized with clinically suspected leptospirosis were enrolled. Plasma and urine were collected on admission and/or at discharge and tested using the LigA-IgM ELISA and a whole cell-based IgM ELISA. Sensitivity and specificity of these tests were evaluated with cases diagnosed by microscopic agglutination test (MAT), culture and LAMP as the composite reference standard and blood bank donors as healthy controls: the mean+3 standard deviation optical density value of healthy controls was used as the cut-off limit (0.062 for the LigA-IgM ELISA and 0.691 for the whole cell-based IgM ELISA). Of 304 patients enrolled in the study, 270 (89.1%) were male and the median age was 30.5 years; 167 (54.9%) were laboratory confirmed. The sensitivity and ROC curve AUC for the LigA-IgM ELISA was significantly greater than the whole cell-based IgM ELISA (69.5% vs. 54.3%, p<0.01; 0.90 vs. 0.82, p<0.01) on admission, but not at discharge. The specificity of LigA-IgM ELISA and whole cell-based IgM ELISA were not significantly different (98% vs. 97%). Among 158 MAT negative patients, 53 and 28 were positive by LigA- and whole cell-based IgM ELISA, respectively; if the laboratory confirmation was re-defined by LigA-IgM ELISA and LAMP, the clinical findings were more characteristic of leptospirosis than the diagnosis based on MAT/culture/LAMP. The newly developed LigA-IgM ELISA is more sensitive than the whole cell-based IgM based ELISA. Although the final diagnosis must be validated by more specific tests, LigA-IgM ELISA could be a useful diagnostic test in a real clinical-setting, where diagnosis is needed in the early phase of infection.
Kitashoji, Emi; Koizumi, Nobuo; Lacuesta, Talitha Lea V.; Usuda, Daisuke; Ribo, Maricel R.; Tria, Edith S.; Go, Winston S.; Kojiro, Maiko; Parry, Christopher M.; Dimaano, Efren M.; Villarama, Jose B.; Ohnishi, Makoto; Suzuki, Motoi; Ariyoshi, Koya
2015-01-01
Background Leptospirosis is an important but largely under-recognized public health problem in the tropics. Establishment of highly sensitive and specific laboratory diagnosis is essential to reveal the magnitude of problem and to improve treatment. This study aimed to evaluate the diagnostic accuracy of a recombinant LigA protein based IgM ELISA during outbreaks in the clinical-setting of a highly endemic country. Methodology/Principal Findings A prospective study was conducted from October 2011 to September 2013 at a national referral hospital for infectious diseases in Manila, Philippines. Patients who were hospitalized with clinically suspected leptospirosis were enrolled. Plasma and urine were collected on admission and/or at discharge and tested using the LigA-IgM ELISA and a whole cell-based IgM ELISA. Sensitivity and specificity of these tests were evaluated with cases diagnosed by microscopic agglutination test (MAT), culture and LAMP as the composite reference standard and blood bank donors as healthy controls: the mean+3 standard deviation optical density value of healthy controls was used as the cut-off limit (0.062 for the LigA-IgM ELISA and 0.691 for the whole cell-based IgM ELISA). Of 304 patients enrolled in the study, 270 (89.1%) were male and the median age was 30.5 years; 167 (54.9%) were laboratory confirmed. The sensitivity and ROC curve AUC for the LigA-IgM ELISA was significantly greater than the whole cell-based IgM ELISA (69.5% vs. 54.3%, p<0.01; 0.90 vs. 0.82, p<0.01) on admission, but not at discharge. The specificity of LigA-IgM ELISA and whole cell-based IgM ELISA were not significantly different (98% vs. 97%). Among 158 MAT negative patients, 53 and 28 were positive by LigA- and whole cell-based IgM ELISA, respectively; if the laboratory confirmation was re-defined by LigA-IgM ELISA and LAMP, the clinical findings were more characteristic of leptospirosis than the diagnosis based on MAT/culture/LAMP. Conclusions/Significance The newly developed LigA-IgM ELISA is more sensitive than the whole cell-based IgM based ELISA. Although the final diagnosis must be validated by more specific tests, LigA-IgM ELISA could be a useful diagnostic test in a real clinical-setting, where diagnosis is needed in the early phase of infection. PMID:26110604
Haighton, C; Halligan, J; Scott, S
2017-04-20
There is concern around alcohol consumption in mid to later life yet little understanding about what influences this behaviour. No previous research has explored the extent to which adults in mid to later life may be exposed to alcohol references in the media. This project aimed to determine the frequency of alcohol references on radio stations with a high proportion of listeners in mid to later life. Content analysis of alcohol references on four popular UK music-based radio stations with a high proportion of listeners aged 55-64 years over three time points. Alcohol references occur frequently, but vary by time of year and type of radio station. When alcohol is mentioned its consumption is portrayed as the norm, without negative consequences. On three commercial stations, the majority of mentions came from advertising, whereas on BBC Radio 2 nearly all references were talk-based. All adverts for direct promotion of alcohol were by supermarkets. Alcohol was frequently associated with celebrations, socializing or something to consume for its own sake. Adults in the age group 55-64 may be exposed to references to alcohol that could serve to reinforce norms of consumption of alcohol and promote purchases of cheap alcohol. © The Author 2017. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Accuracy of velocities from repeated GPS surveys: relative positioning is concerned
NASA Astrophysics Data System (ADS)
Duman, Huseyin; Ugur Sanli, D.
2016-04-01
Over more than a decade, researchers have been interested in studying the accuracy of GPS positioning solutions. Recently, reporting the accuracy of GPS velocities has been added to this. Researchers studying landslide motion, tectonic motion, uplift, sea level rise, and subsidence still report results from GPS experiments in which repeated GPS measurements from short sessions are used. This motivated some other researchers to study the accuracy of GPS deformation rates/velocities from various repeated GPS surveys. In one of the efforts, the velocity accuracy was derived from repeated GPS static surveys using short observation sessions and Precise Point Positioning mode of GPS software. Velocities from short GPS sessions were compared with the velocities from 24 h sessions. The accuracy of velocities was obtained using statistical hypothesis testing and quantifying the accuracy of least squares estimation models. The results reveal that 45-60 % of the horizontal and none of the vertical solutions comply with the results from 24 h solutions. We argue that this case in which the data was evaluated using PPP should also apply to the case in which the data belonging to long GPS base lengths is processed using fundamental relative point positioning. To test this idea we chose the two IGS stations ANKR and NICO and derive their velocities from the reference stations held fixed in the stable EURASIAN plate. The University of Bern's GNSS software BERNESE was used to produce relative positioning solutions, and the results are compared with those of GIPSY/OASIS II PPP results. First impressions indicate that it is worth designing a global experiment and test these ideas in detail.
NASA Astrophysics Data System (ADS)
Gerzen, T.; Minkwitz, D.
2016-01-01
The accuracy and availability of satellite-based applications like GNSS positioning and remote sensing crucially depends on the knowledge of the ionospheric electron density distribution. The tomography of the ionosphere is one of the major tools to provide link specific ionospheric corrections as well as to study and monitor physical processes in the ionosphere. In this paper, we introduce a simultaneous multiplicative column-normalized method (SMART) for electron density reconstruction. Further, SMART+ is developed by combining SMART with a successive correction method. In this way, a balancing between the measurements of intersected and not intersected voxels is realised. The methods are compared with the well-known algebraic reconstruction techniques ART and SART. All the four methods are applied to reconstruct the 3-D electron density distribution by ingestion of ground-based GNSS TEC data into the NeQuick model. The comparative case study is implemented over Europe during two periods of the year 2011 covering quiet to disturbed ionospheric conditions. In particular, the performance of the methods is compared in terms of the convergence behaviour and the capability to reproduce sTEC and electron density profiles. For this purpose, independent sTEC data of four IGS stations and electron density profiles of four ionosonde stations are taken as reference. The results indicate that SMART significantly reduces the number of iterations necessary to achieve a predefined accuracy level. Further, SMART+ decreases the median of the absolute sTEC error up to 15, 22, 46 and 67 % compared to SMART, SART, ART and NeQuick respectively.
Update on the activities of the GGOS Bureau of Networks and Observations
NASA Technical Reports Server (NTRS)
Pearlman, Michael R.; Pavlis, Erricos C.; Ma, Chopo; Noll, Carey; Thaller, Daniela; Richter, Bernd; Gross, Richard; Neilan, Ruth; Mueller, Juergen; Barzaghi, Ricardo;
2016-01-01
The recently reorganized GGOS Bureau of Networks and Observations has many elements that are associated with building and sustaining the infrastructure that supports the Global Geodetic Observing System (GGOS) through the development and maintenance of the International Terrestrial and Celestial Reference Frames, improved gravity field models and their incorporation into the reference frame, the production of precision orbits for missions of interest to GGOS, and many other applications. The affiliated Service Networks (IVS, ILRS, IGS, IDS, and now the IGFS and the PSMSL) continue to grow geographically and to improve core and co-location site performance with newer technologies. Efforts are underway to expand GGOS participation and outreach. Several groups are undertaking initiatives and seeking partnerships to update existing sites and expand the networks in geographic areas void of coverage. New satellites are being launched by the Space Agencies in disciplines relevant to GGOS. Working groups now constitute an integral part of the Bureau, providing key service to GGOS. Their activities include: projecting future network capability and examining trade-off options for station deployment and technology upgrades, developing metadata collection and online availability strategies; improving coordination and information exchange with the missions for better ground-based network response and space-segment adequacy for the realization of GGOS goals; and standardizing site-tie measurement, archiving, and analysis procedures. This poster will present the progress in the Bureau's activities and its efforts to expand the networks and make them more effective in supporting GGOS.
NASA Astrophysics Data System (ADS)
Park, J.; Sreeja, V.; Aquino, M.; Cesaroni, C.; Spogli, L.; Dodson, A.; De Franceschi, G.
2016-05-01
Ionospheric scintillation occurs mainly at high and low latitude regions of the Earth and may impose serious degradation on GNSS (Global Navigation Satellite System) functionality. The Brazilian territory sits on one of the most affected areas of the globe, where the ionosphere behaves very unpredictably, with strong scintillation frequently occurring in the local postsunset hours. The correlation between scintillation occurrence and sharp variations in the ionospheric total electron content (TEC) in Brazil is demonstrated in Spogli et al. (2013). The compounded effect of these associated ionospheric disturbances on long baseline GNSS kinematic positioning is studied in this paper, in particular when ionospheric maps are used to aid the positioning solution. The experiments have been conducted using data from GNSS reference stations in Brazil. The use of a regional TEC map generated under the CALIBRA (Countering GNSS high-Accuracy applications Limitations due to Ionospheric disturbances in BRAzil) project, referred to as CALIBRA TEC map (CTM), was compared to the use of the Global Ionosphere Map (GIM), provided by the International GNSS Service (IGS). Results show that the use of the CTM greatly improves the kinematic positioning solution as compared with that using the GIM, especially under disturbed ionospheric conditions. Additionally, different hypotheses were tested regarding the precision of the TEC values obtained from ionospheric maps, and its effect on the long baseline kinematic solution evaluated. Finally, this study compares two interpolation methods for ionospheric maps, namely, the Inverse Distance Weight and the Natural Neighbor.
Yu, Tina; Qu, Shoufang; Zhang, Xiaoyan; Sun, Nan; Gao, Shangxian; Li, Haining; Huang, Jie
2015-07-01
To evaluate the quality status of rubella virus IgM diagnostic kits by national supervising sampling. Using legal inspection combining with exploratory study, the positive and negative coincidence rate, detection limit and repeatability of kits were verified. The results showed that 15 of 16 batches of kits were qualified using legal inspection, and the passing rate was 93.8%. The unqualified item was negative coincidence rate. In exploratory study, only 11 batches (68.8%) complied with industry standard. The unqualified items were negative coincidence rate, detection limit and repeatability. At present, rubella virus IgM diagnostic Kits have some quality problems in the market. It is recommended that we adopt industry standard and national reference panel in the registration inspection for the future, which will prompt enterprises to improve quality.
Case, J; Ford, D S; Chung, A; Collins, R; Kochman, S; Mazda, T; Overbeeke, M; Perera, R; Sakuldamrongpanich, T; Scott, M; Voak, D; Zupańska, B
1999-01-01
An international working party has conducted a study designed to select a suitable reference reagent for antihuman globulin, to replace those first made available in 1987. The chosen preparation contains levels of anti-IgG and anti-C3 (anti-C3c and anti-C3d) potency that are considered suitable to serve for reference when evaluating either polyspecific antihuman globulin reagents or those containing their separate monospecific components. The reference material is available in 2-ml freeze-dried aliquots from seven assigned distribution centres.
NASA Astrophysics Data System (ADS)
Berrocoso, M.; Fernandez-Ros, A.; Prates, G.; Martin, M.; Hurtado, R.; Pereda, J.; Garcia, M. J.; Garcia-Cañada, L.; Ortiz, R.; Garcia, A.
2012-04-01
The surface deformation has been an essential parameter for the onset and evolution of the eruptive process of the island of El Hierro (October 2011) as well as for forecasting changes in seismic and volcanic activity during the crisis period. From GNSS-GPS observations the reactivation is early detected by analizing the change in the deformation of the El Hierro Island regional geodynamics. It is found that the surface deformation changes are detected before the occurrence of seismic activity using the station FRON (GRAFCAN). The evolution of the process has been studied by the analysis of time series of topocentric coordinates and the variation of the distance between stations on the island of El Hierro (GRAFCAN station;IGN network; and UCA-CSIC points) and LPAL-IGS station on the island of La Palma. In this work the main methodologies and their results are shown: •The location (and its changes) of the litospheric pressure source obtained by applying the Mogi model. •Kalman filtering technique for high frequency time series, used to make the forecasts issued for volcanic emergency management. •Correlations between deformation of the different GPS stations and their relationship with seismovolcanic settings.
Status and Perspective of the IGS Multi-GNSS Experiment (MGEX)
NASA Astrophysics Data System (ADS)
Steigenberger, Peter; Montenbruck, Oliver; Weber, Robert; Hugentobler, Urs
2013-04-01
Following three decades, during which the Global Positioning System GPS has evolved from a military navigation system into an indispensable tool for geodetic research and global monitoring of the Earth, the world of satellite navigation has experienced dramatic changes over the past years. With GLONASS, a second global navigation system has achieved a fully operational status, GPS is introducing modernized civil and encrypted navigation signals, and a variety of new navigation constellations are being built-up in Asia and Europe. These include BeiDou, which has recently opened a regional navigation service in the Asia-Pacific region, Galileo, which now has four satellites in orbit, as well as QZSS, which offers a unique set of signals and service features. In recognition of a rapidly changing GNSS landscape, the International GNSS Service (IGS) has initiated the Multi-GNSS Experiment (MGEX - http://igs.org/mgex) as a platform for early familiarization with emerging navigation systems and to pave the way for a full-featured use thereof in a future multi-GNSS service. As a first step, MGEX has promoted the build-up of a new global network of GNSS monitoring stations, each tracking at least one new constellation (Galileo, BeiDou, or QZSS) on top of GPS, GLONASS and SBAS. By the end of 2012, approximately 50 stations contribute offline and/or real-time data to the MGEX network. To facilitate introduction of new standards (specifically RINEX3 observation and navigation data formats), distinct data archives are used even for those MGEX stations jointly contributing to the legacy IGS. Building-up on the new multi-GNSS network, the generation of associated orbit and clock products has started in the second quarter of 2012. At this stage, only Galileo and QZSS products are offered by selected MGEX Analysis Centers, but the addition of BeiDou is expected in 2013 as the MGEX network expands and new Analysis Centers join the data processing effort. Despite remarkable progress in the first year of the MGEX project, numerous challenges have still to be met before the new constellations can contribute to high-grade navigation and geodetic services. So far, only an immature knowledge of the new navigation satellites and the transmitted signals is available. Much work is left to fully characterize the multitude of inter-signal, inter-frequency and inter-system biases, as well as antenna phase patterns in both the space and user segment. Likewise, proper knowledge of spacecraft attitude control and radiation pressure models appears indispensable for a proper generation of highly-accurate orbit and clock products. Only then will users be able to fully benefit from the high potential of robust, wide-band, and high navigation signals as well as new generations of highly stable clocks offered by the new constellations. Within the presentation, the MGEX project will be introduced and the latest achievements in the network build-up, the product generation and related activities will be presented. Current challenges and necessary steps towards a full-features multi-GNSS service of the IGS will be identified.
Nie, Min; Chen, Dong; Gao, Zhenyan; Wu, Xinyu; Li, Tong
2016-01-01
Background Dental caries is a well-known biofilm-mediated disease initiated by Streptococcus mutans, which should infect and colonize in a milieu perfused with components of the mucosal immune system. Little is known, however, regarding the relationship between the natural secretory IgA activity and S. mutans of a variety of diverse genotypes. Objectives The current study aimed to use spousal pairs to investigate the natural immunoreactivity of salivary secretory IgA to different genotype strains of S. mutans. Patients and Methods Indigenous strains were characterized from nine spousal pairs using polymerase reaction chain (PCR) and arbitrarily primed polymerase chain reaction (AP-PCR) by genotype monitoring. Unstimulated submandibular/sublingual secretions were collected and the concentrations of secretory IgA were determined by the enzyme-linked immunosorbent assay (ELISA). Each saliva sample was examined by Western blot to analyze the immunoreactivity of naturally occurring salivary secretory IgA antibodies for his/her own indigenous strain, spouse’s strain and reference strains including S. mutans GS-5 and Ingbritt (C). Results The results showed that naturally induced salivary IgA antibodies against S. mutans were present in all subjects. Almost all subjects had the similar individual immunoblotting profiles to different genotype strains. Conclusions The current study indicated that the immunoreactivity of secretory IgA might have no direct correlation with the colonization of indigenous flora and rejection of exogenous strains in adults. The relationship of microbes, host and dental caries should be in the light of coevolved microecosystem as a whole, but not caused by one factor alone. PMID:27303613
Matthews, Allysia J.; Zheng, Simin; DiMenna, Lauren J.; Chaudhuri, Jayanta
2014-01-01
Upon encountering antigens, mature IgM-positive B lymphocytes undergo class-switch recombination (CSR) wherein exons encoding the default Cμ constant coding gene segment of the immunoglobulin (Ig) heavy-chain (Igh) locus are excised and replaced with a new constant gene segment (referred to as “Ch genes”, e.g., Cγ, Cε, or Cα). The B cell thereby changes from expressing IgM to one producing IgG, IgE, or IgA, with each antibody isotype having a different effector function during an immune reaction. CSR is a DNA deletional-recombination reaction that proceeds through the generation of DNA double-strand breaks (DSBs) in repetitive switch (S) sequences preceding each Ch gene and is completed by end-joining between donor Sμ and acceptor S regions. CSR is a multistep reaction requiring transcription through S regions, the DNA cytidine deaminase AID, and the participation of several general DNA repair pathways including base excision repair, mismatch repair, and classical nonhomologous end-joining. In this review, we discuss our current understanding of how transcription through S regions generates substrates for AID-mediated deamination and how AID participates not only in the initiation of CSR but also in the conversion of deaminated residues into DSBs. Additionally, we review the multiple processes that regulate AID expression and facilitate its recruitment specifically to the Ig loci, and how deregulation of AID specificity leads to oncogenic translocations. Finally, we summarize recent data on the potential role of AID in the maintenance of the pluripotent stem cell state during epigenetic reprogramming. PMID:24507154
Alvaro, Montserrat; Giner, Ma Teresa; Vázquez, Marta; Lozano, Jaime; Domínguez, Olga; Piquer, Mónica; Días, Marcia; Jiménez, Rosa; Martín, Ma Anunciación; Alsina, Laia; Plaza, Ana Ma
2012-09-01
Cow's milk allergy is the most frequent childhood food allergy. Children older than 5 who have not become tolerant have less probabilities of natural tolerance. Specific oral desensitization methods are being investigated in reference centres. The aims of our study were to assess the efficacy of our guideline of specific oral desensitization to cow's milk in children and to know its suitability for anaphylactic children. Both clinical and specific IgE outcomes were evaluated. Eighty-seven children aged 5 to 16 years with a history of cow's milk allergy were included. Prior to desensitization, skin prick test, specific IgE to cow's milk proteins and a double-blind placebo control food challenge were performed in all. Of the 87 patients, 21 had a negative challenge; they were considered tolerant, and they were told to follow a free diet. Of the positive, 44 were anaphylactic and 22 non-anaphylactic. All of them were included. In non-anaphylactic patients, 6 achieved partial and 16 maximum desensitization after 23.1 weeks. In the anaphylactic group, 7 achieved partial and 35 maximum desensitization after 26.4 weeks. Cow's milk-specific IgE levels and casein-specific IgE levels were significantly lower in the tolerant patients at baseline. One year after desensitization, the medium specific cow's milk levels and casein IgE levels had dropped significantly. Our guideline for specific oral desensitization to cow's milk is efficacious even in patients with anaphylactic reactions to cow's milk and represents a significant life change. Immunological changes in 1 year show a drop in cow's milk protein-specific IgE.
Evaluation of Commercially Available Chikungunya Virus Immunoglobulin M Detection Assays
Johnson, Barbara W.; Goodman, Christin H.; Holloway, Kimberly; de Salazar, P. Martinez; Valadere, Anne M.; Drebot, Michael A.
2016-01-01
Commercial chikungunya virus (CHIKV)–specific IgM detection kits were evaluated at the Centers for Disease Control and Prevention (CDC), the Public Health Agency of Canada National Microbiology Laboratory, and the Caribbean Public Health Agency (CARPHA). The Euroimmun Anti-CHIKV IgM ELISA kit had ≥ 95% concordance with all three reference laboratory results. The limit of detection for low CHIK IgM+ samples, as measured by serial dilution of seven sera up to 1:12,800 ranged from 1:800 to 1:3,200. The Euroimmun IIFT kit evaluated at CDC and CARPHA performed well, but required more retesting of equivocal results. The InBios CHIKjj Detect MAC-ELISA had 100% and 98% concordance with CDC and CARPHA results, respectively, and had equal sensitivity to the CDC MAC-ELISA to 1:12,800 dilution in serially diluted samples. The Abcam Anti-CHIKV IgM ELISA had high performance at CARPHA, but at CDC, performance was inconsistent between lots. After replacement of the biotinylated IgM antibody controls with serum containing CHIKV-specific IgM and additional quality assurance/control measures, the Abcam kit was rereleased and reevaluated at CDC. The reformatted Abcam kit had 97% concordance with CDC results and limit of detection of 1:800 to 1:3,200. Two rapid tests and three other CHIKV MAC-ELISAs evaluated at CDC had low sensitivity, as the CDC CHIKV IgM in-house positive controls were below the level of detection. In conclusion, laboratories have options for CHIKV serological diagnosis using validated commercial kits. PMID:26976887
NASA Astrophysics Data System (ADS)
St Fleur, Sadrac; Courboulex, Francoise; Bertrand, Etienne; Deschamps, Anne; Mercier de Lepinay, Bernard; Prepetit, Claude; Hough, Suzan
2013-04-01
We present the preliminary results of a study with the aim of understanding how some combinations of source and site effects can generate extreme ground motions in the city of Port au Prince. For this study, we have used the recordings of several tens of earthquakes with magnitude larger than 3.0 at 3 to 14 stations from three networks: 3 stations of the Canadian Broad-band network (RNCan), 2 stations of the educational French network (SaE) and 9 stations of the accelerometric network (Bureau des Mines et de l'Energie of Port au Prince and US Geological survey). In order to estimate site effects under each station, we have applied classical spectral ratio methods: The H/V (Horizontal/Vertical) method was first used to select a reference station, which was itself used in a site/reference method. Because a true reference station was not available, we have used successively stations HCEA, then station PAPH, then an average value of 3 stations. In the frequency range studied (0.5 - 20 Hz), we found a site-to-reference ratio up to 3 to 8. However, these values present a large variability, depending on the earthquake recordings. This may indicate that the observed amplification from one station to the other depends not only from the local site effect but also from the source. We then used the same earthquake recordings as Empirical Green's Functions (EGF) in order to simulate the ground motions generated by a virtual earthquake. For this simulation, we have used a stochastic EGF summation method. We have worked on the simulation of a magnitude Mw=6.8 using successively 2 smaller events that occurred on the Leogane fault as EGF. The results obtained using the two events are surprisingly very different. Using the first EGF, we obtained almost the same ground motion values at each station in Port au Prince, whereas with the second EGF, the results highlight large differences. The large variability obtained in the results indicates that a particular combination of site and source effects may be responsible of large ground motions, especially at some given sites.
A Filtering of Incomplete GNSS Position Time Series with Probabilistic Principal Component Analysis
NASA Astrophysics Data System (ADS)
Gruszczynski, Maciej; Klos, Anna; Bogusz, Janusz
2018-04-01
For the first time, we introduced the probabilistic principal component analysis (pPCA) regarding the spatio-temporal filtering of Global Navigation Satellite System (GNSS) position time series to estimate and remove Common Mode Error (CME) without the interpolation of missing values. We used data from the International GNSS Service (IGS) stations which contributed to the latest International Terrestrial Reference Frame (ITRF2014). The efficiency of the proposed algorithm was tested on the simulated incomplete time series, then CME was estimated for a set of 25 stations located in Central Europe. The newly applied pPCA was compared with previously used algorithms, which showed that this method is capable of resolving the problem of proper spatio-temporal filtering of GNSS time series characterized by different observation time span. We showed, that filtering can be carried out with pPCA method when there exist two time series in the dataset having less than 100 common epoch of observations. The 1st Principal Component (PC) explained more than 36% of the total variance represented by time series residuals' (series with deterministic model removed), what compared to the other PCs variances (less than 8%) means that common signals are significant in GNSS residuals. A clear improvement in the spectral indices of the power-law noise was noticed for the Up component, which is reflected by an average shift towards white noise from - 0.98 to - 0.67 (30%). We observed a significant average reduction in the accuracy of stations' velocity estimated for filtered residuals by 35, 28 and 69% for the North, East, and Up components, respectively. CME series were also subjected to analysis in the context of environmental mass loading influences of the filtering results. Subtraction of the environmental loading models from GNSS residuals provides to reduction of the estimated CME variance by 20 and 65% for horizontal and vertical components, respectively.
Evaluation of temperature differences for paired stations of the U.S. Climate Reference Network
Gallo, K.P.
2005-01-01
Adjustments to data observed at pairs of climate stations have been recommended to remove the biases introduced by differences between the stations in time of observation, temperature instrumentatios, latitude, and elevation. A new network of climate stations, located in rural settings, permits comparisons of temperatures for several pairs of stations without two of the biases (time of observation and instrurtientation). The daily, monthly, and annual minimum, maximum, and mean temperatures were compared for five pairs of stations included in the U.S. Climate Reference Network. Significant differences were found between the paired stations in the annual minimum, maximum, and mean temperatures for all five pairs of stations. Adjustments for latitude and elevation differences contributed to greater differences in mean annual temperature for four of the five stations. Lapse rates computed from the mean annual temperature differences between station pairs differed from a constant value, whether or not latitude adjustments were made to the data. The results suggest that microclimate influences on temperatures observed at nearby (horizontally and vertically) stations are potentially much greater than influences that might be due to latitude or elevation differences between the stations. ?? 2005 American Meteorological Society.
Yergeau, Etienne; Maynard, Christine; Sanschagrin, Sylvie; Champagne, Julie; Juck, David; Lee, Kenneth; Greer, Charles W
2015-09-01
Several studies have assessed the effects of the released oil on microbes, either during or immediately after the Deepwater Horizon accident. However, little is known about the potential longer-term persistent effects on microbial communities and their functions. In this study, one water column station near the wellhead (3.78 km southwest of the wellhead), one water column reference station outside the affected area (37.77 km southeast of the wellhead), and deep-sea sediments near the wellhead (3.66 km southeast of the wellhead) were sampled 1 year after the capping of the well. In order to analyze microbial community composition, function, and activity, we used metagenomics, metatranscriptomics, and mineralization assays. Mineralization of hexadecane was significantly higher at the wellhead station at a depth of ∼1,200 m than at the reference station. Community composition based on taxonomical or functional data showed that the samples taken at a depth of ∼1,200 m were significantly more dissimilar between the stations than at other depths (surface, 100 m, 750 m, and >1,500 m). Both Bacteria and Archaea showed reduced activity at depths of ∼1,200 m when the wellhead station was compared to the reference station, and their activity was significantly higher in surficial sediments than in 10-cm sediments. Surficial sediments also harbored significantly different active genera than did 5- and 10-cm sediments. For the remaining microbial parameters assessed, no significant differences could be observed between the wellhead and reference stations and between surface and 5- to 10-cm-deep sediments. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
NASA Astrophysics Data System (ADS)
Snyder, R. L.; Mancosu, N.; Spano, D.
2014-12-01
This study derived the summer (June-August) reference evapotranspiration distribution map for Sardinia (Italy) based on weather station data and use of the geographic information system (GIS). A modified daily Penman-Monteith equation from the Food and Agriculture Organization of the United Nations (UN-FAO) and the American Society of Civil Engineers Environmental and Water Resources Institute (ASCE-EWRI) was used to calculate the Standardized Reference Evapotranspiration (ETos) for all weather stations having a "full" set of required data for the calculations. For stations having only temperature data (partial stations), the Hargreaves-Samani equation was used to estimate the reference evapotranspiration for a grass surface (ETo). The ETos and ETo results were different depending on the local climate, so two methods to estimate ETos from the ETo were tested. Substitution of missing solar radiation, wind speed, and humidity data from a nearby station within a similar microclimate was found to give better results than using a calibration factor that related ETos and ETo. Therefore, the substitution method was used to estimate ETos at "partial" stations having only temperature data. The combination of 63 full and partial stations was sufficient to use GIS to map ETos for Sardinia. Three interpolation methods were studied, and the ordinary kriging model fitted the observed data better than a radial basis function or the inverse distance weighting method. Using station data points to create a regional map simplified the zonation of ETos when large scale computations were needed. Making a distinction based on ETos classes allows the simulation of crop water requirements for large areas and it can potentially lead to improved irrigation management and water savings. It also provides a baseline to investigate possible impact of climate change.
The diagnosis of food allergy: a systematic review and meta-analysis.
Soares-Weiser, K; Takwoingi, Y; Panesar, S S; Muraro, A; Werfel, T; Hoffmann-Sommergruber, K; Roberts, G; Halken, S; Poulsen, L; van Ree, R; Vlieg-Boerstra, B J; Sheikh, A
2014-01-01
We investigated the accuracy of tests used to diagnose food allergy. Skin prick tests (SPT), specific-IgE (sIgE), component-resolved diagnosis and the atopy patch test (APT) were compared with the reference standard of double-blind placebo-controlled food challenge. Seven databases were searched and international experts were contacted. Two reviewers independently identified studies, extracted data, and used QUADAS-2 to assess risk of bias. Where possible, meta-analysis was undertaken. Twenty-four (2831 participants) studies were included. For cows' milk allergy, the pooled sensitivities were 53% (95% CI 33-72), 88% (95 % CI 76-94), and 87% (95% CI 75-94), and specificities were 88% (95% CI 76-95), 68% (95% CI 56-77), and 48% (95% CI 36-59) for APT, SPT, and sIgE, respectively. For egg, pooled sensitivities were 92% (95% CI 80-97) and 93% (95% CI 82-98), and specificities were 58% (95% CI 49-67) and 49% (40-58%) for skin prick tests and specific-IgE. For wheat, pooled sensitivities were 73% (95% CI 56-85) and 83% (95% CI 69-92), and specificities were 73% (95% CI 48-89) and 43% (95% CI 20-69%) for SPT and sIgE. For soy, pooled sensitivities were 55% (95% CI 33-75) and 83% (95% CI 64-93), and specificities were 68% (95% CI 52-80) and 38% (95% CI 24-54) for SPT and sIgE. For peanut, pooled sensitivities were 95% (95% CI 88-98) and 96% (95% CI 92-98), and specificities were 61% (95% CI 47-74), and 59% (95% CI 45-72) for SPT and sIgE. The evidence base is limited and weak and is therefore difficult to interpret. Overall, SPT and sIgE appear sensitive although not specific for diagnosing IgE-mediated food allergy. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Lowenski, Steeve; Durand, Benoit; Bahuon, Céline; Zientara, Stéphan; Lecollinet, Sylvie
2017-01-01
West Nile Fever is a zoonotic disease caused by a mosquito-borne flavivirus, WNV. By its clinical sensitivity to the disease, the horse is a useful sentinel of infection. Because of the virus’ low-level, short-term viraemia in horses, the primary tools used to diagnose WNV are serological tests. Inter-laboratory proficiency tests (ILPTs) were held in 2010 and 2013 to evaluate WNV serological diagnostic tools suited for the European network of National Reference Laboratories (NRLs) for equine diseases. These ILPTs were designed to evaluate the laboratories’ and methods’ performances in detecting WNV infection in horses through serology. The detection of WNV immunoglobulin G (IgG) antibodies by ELISA is widely used in Europe, with 17 NRLs in 2010 and 20 NRLs in 2013 using IgG WNV assays. Thanks to the development of new commercial IgM capture kits, WNV IgM capture ELISAs were rapidly implemented in NRLs between 2010 (4 NRLs) and 2013 (13 NRLs). The use of kits allowed the quick standardisation of WNV IgG and IgM detection assays in NRLs with more than 95% (20/21) and 100% (13/13) of satisfactory results respectively in 2013. Conversely, virus neutralisation tests (VNTs) were implemented in 33% (7/21) of NRLs in 2013 and their low sensitivity was evidenced in 29% (2/7) of NRLs during this ILPT. A comparison of serological diagnostic methods highlighted the higher sensitivity of IgG ELISAs compared to WNV VNTs. They also revealed that the low specificity of IgG ELISA kits meant that it could detect animals infected with other flaviviruses. In contrast VNT and IgM ELISA assays were highly specific and did not detect antibodies against related flaviviruses. These results argue in favour of the need for and development of new, specific serological diagnostic assays that could be easily transferred to partner laboratories. PMID:28915240
Active tectonics on Lanzarote (Canary Islands) from the analysis of CGPS data
NASA Astrophysics Data System (ADS)
Riccardi, Umberto; Arnoso, Jose; Benavent, María Teresa; Velez, Emilio; Tammaro, Umberto; González Montesinos, Fuensanta
2017-04-01
We report on the analysis of about three years of CGPS data collected on a small network consisting in five permanent stations, with the largest baseline up to 40 km, spread over Timanfaya National Park in Lanzarote Island. The GPS stations are operated by different institutions, as follows: CAME is co-operated by the Institute of Geosciences (CSIC-UCM), DiSTAR and the Geodesy Research Group of University Complutense of Madrid (GRG-UCM), while LACV is operated by (CSIC-UCM and GRG-UCM). Stations HRIA, TIAS, YAIZ, belong to GRAFCAN (Cartographical Service of the Government of Canary Islands). Lanzarote is the most Northeast and the oldest island of the Canarian Archipelago (Spain), which is located on a transitional zone, a passive margin, between oceanic and continental crust. Due to some peculiarities in geochemistry and geochronology of the rocks as well as tectonics, the origin of the archipelago from a hot spot is still debated. In fact, the most recent Holocenic volcanism is scattered over the islands and the last eruption was a submarine one, occurred in October 2011 at El Hierro Island. The last eruption in Lanzarote was a 7 years voluminous eruptive cycle, occurred during the 18th century. Historical seismicity registered in the region, is customarily attributed to diffuse tectonic activity. This study is intended to contributing to shed light on the active tectonics on Lanzarote island and to separate between local and regional strain fields. With the aid of Gamit 10.6 software, we compute from the GPS observations the "ionofree" linear combinations in order to obtain the positions of the stations in ITRF2008 frame using daily sessions, and IGS precise ephemeris. The frame referencing of the network is realized by eleven IGS GPS stations. Then through a Kalman filtering procedure, implemented in GLOBK software, we obtain the final daily solutions by constraining the fiducial GPS stations to their ITRF2008 coordinates. For a reliable strain field retrieval, a careful study is preliminarily carried out on the time series of the daily solutions aimed at characterizing and filtering out the seasonal periodicities related to "non-tectonic" sources. A tentative strain field is reconstructed through the analysis of the time evolution of the web of the possible baselines ranging the stations. Finally, we try to interpret the observed displacement and strain field in the framework of the known tectonic setting coming from previous and ongoing geophysical studies.
NASA Astrophysics Data System (ADS)
Yuan, Y.; Tscherning, C. C.; Knudsen, P.; Xu, G.; Ou, J.
2008-01-01
A new method for modeling the ionospheric delay using global positioning system (GPS) data is proposed, called the ionospheric eclipse factor method (IEFM). It is based on establishing a concept referred to as the ionospheric eclipse factor (IEF) λ of the ionospheric pierce point (IPP) and the IEF’s influence factor (IFF) bar{λ}. The IEF can be used to make a relatively precise distinction between ionospheric daytime and nighttime, whereas the IFF is advantageous for describing the IEF’s variations with day, month, season and year, associated with seasonal variations of total electron content (TEC) of the ionosphere. By combining λ and bar{λ} with the local time t of IPP, the IEFM has the ability to precisely distinguish between ionospheric daytime and nighttime, as well as efficiently combine them during different seasons or months over a year at the IPP. The IEFM-based ionospheric delay estimates are validated by combining an absolute positioning mode with several ionospheric delay correction models or algorithms, using GPS data at an international Global Navigation Satellite System (GNSS) service (IGS) station (WTZR). Our results indicate that the IEFM may further improve ionospheric delay modeling using GPS data.
NASA Astrophysics Data System (ADS)
Koenig, Daniel
2018-02-01
Applying a one-step integrated process, i.e. by simultaneously processing all data and determining all satellite orbits involved, a Terrestrial Reference Frame (TRF) consisting of a geometric as well as a dynamic part has been determined at the observation level using the EPOS-OC software of Deutsches GeoForschungsZentrum. The satellite systems involved comprise the Global Positioning System (GPS) as well as the twin GRACE spacecrafts. Applying a novel approach, the inherent datum defect has been overcome empirically. In order not to rely on theoretical assumptions this is done by carrying out the TRF estimation based on simulated observations and using the associated satellite orbits as background truth. The datum defect is identified here as the total of all three translations as well as the rotation about the z-axis of the ground station network leading to a rank-deficient estimation problem. To rectify this singularity, datum constraints comprising no-net translation (NNT) conditions in x, y, and z as well as a no-net rotation (NNR) condition about the z-axis are imposed. Thus minimally constrained, the TRF solution covers a time span of roughly a year with daily resolution. For the geometric part the focus is put on Helmert transformations between the a priori and the estimated sets of ground station positions, and the dynamic part is represented by gravity field coefficients of degree one and two. The results of a reference solution reveal the TRF parameters to be estimated reliably with high precision. Moreover, carrying out a comparable two-step approach using the same data and models leads to parameters and observational residuals of worse quality. A validation w.r.t. external sources shows the dynamic origin to coincide at a level of 5 mm or better in x and y, and mostly better than 15 mm in z. Comparing the derived GPS orbits to IGS final orbits as well as analysing the SLR residuals for the GRACE satellites reveals an orbit quality on the few cm level. Additional TRF test solutions demonstrate that K-Band Range-Rate observations between both GRACE spacecrafts are crucial for accurately estimating the dynamic frame's orientation, and reveal the importance of the NNT- and NNR-conditions imposed for estimating the components of the dynamic geocenter.
Underwater Facilities Inspections and Assessments at U.S. Naval Station, Guantanamo Bay, Cuba.
1980-08-01
4A O* PIPE BAY 7 f . . , -4*DA OO QIk ,,NC E7 i It SOA ICNCE Sub i I li 2’ o Rpais f sallngconret, raced ireran % . aeasme pf biii ig coceth e...FNCII.TI’lIFS UJNDIzRWATER INSPEC’flON RElPORT ---------------- I’IER V (VICTOR) .- -------- ----------------------------------------- 7 DESCRI 1I’l...UN --------------------------------------------------------- 7 INSPECTION RESULTS ------------------------------------------------- 7 CONCLUSIONS AND
Moreno Ramíez, Everardo; Hernández Urzúa, Miguel Angel; González Villegas, Ana Cecilia; Casas Solís, Josefina; Zaitseva, Galina
2006-01-01
Urban environmental pollutants, resulting from the inadequate control in the industries and from the use of vehicles, still represent a great danger for millions of people all around the world. We made a study in healthy young people without family history of atopy that lived in Guadalajara's downtown, as well as in another group of young people who lived in a rural area. According to the census of the year 2000, Guadalajara city has a population of 4 million habitants, and a vehicle number of about a million. The immunological parameters that we studied were: IgG, IgA and IgM immunoglobulins by nephelometry, serum levels of proinflammatory cytokines IL-6, IL-1alpha, IL1-beta and TNF-alpha by ELISAs test, and the phagocytic index in polymorphonuclears. The atmospheric parameters were: NO2, O3, SO2, CO and the suspended particles that were less than 10 micrometers (PM10). These parameters were obtained from a mobile unit found at the Instituto de Astronomia y Meteorología de la Universidad de Guadalajara, and from an automatic station of environmental monitoring. It stands out the high concentrations of NO2 and PM10, which in several occasions were over the standards established by the WHO. IgG, IgA and IgM immunoglobulins were lower in the subjects living in the city that in those who lived in the rural area. Phagocytic index in polymorphonuclears, as well as IL-1alpha levels were higher in the city group, though we did not find a significant difference in the immunological parameters analyzed in the studied groups. Environmental pollution levels found at Guadalajara's downtown does not modify the immunological parameters studied in the peripheral blood of healthy young people. This shows that this group of population is less vulnerable than others to the exposition of moderate levels of urban air pollution.
EUPOS - Satellite multifunctional system of reference stations in Central and Eastern Europe
NASA Astrophysics Data System (ADS)
Sledzinski, J.
2003-04-01
The European project EUPOS (European Position Determination System) of establishment of a system of multifunctional satellite reference stations in Central and Eastern Europe is described in the paper. Fifteen countries intend to participate in the project: Bulgaria, Croatia, Czech Republic, Estonia, Germany, Hungary, Latvia, Lithuania, Macedonia, Poland, Romania, Russia, Serbia, Slovak Republic and Slovenia. One common project will be prepared for all countries, however it will include the existing or developed infrastructure in particular countries. The experiences of establishing and operating of the German network SAPOS as well as experiences gained by other countries will be used. The European network of stations will be compatible with the system SAPOS and future European system Galileo. The network of reference stations will provide signal for both positioning of the geodetic control points and for land, air and marine navigation. Several levels of positioning accuracy will be delivered.
Seasonal station variations in the Vienna VLBI terrestrial reference frame VieTRF16a
NASA Astrophysics Data System (ADS)
Krásná, Hana; Böhm, Johannes; Madzak, Matthias
2017-04-01
The special analysis center of the International Very Long Baseline Interferometry (VLBI) Service for Geodesy and Astrometry (IVS) at TU Wien (VIE) routinely analyses the VLBI measurements and estimates its own Terrestrial Reference Frame (TRF) solutions. We present our latest solution VieTRF16a (1979.0 - 2016.5) computed with the software VieVS version 3.0. Several recent updates of the software have been applied, e.g., the estimation of annual and semi-annual station variations as global parameters. The VieTRF16a is determined in the form of the conventional model (station position and its linear velocity) simultaneously with the celestial reference frame and Earth orientation parameters. In this work, we concentrate on the seasonal station variations in the residual time series and compare our TRF with the three combined TRF solutions ITRF2014, DTRF2014 and JTRF2014.
GNSS-Derived Water Vapour for Riyadh from SOLA IGS Station
NASA Astrophysics Data System (ADS)
Maghrabi, Abdullrahman; Alothman, Abdulaziz; Fernandes, Rui; Aodah, Souad
2017-04-01
Water vapor is the most abundant and highly variable component of the important gases in the atmosphere. It influences many physical and thermodynamical processes in the atmosphere and plays an important role in the hydrological cycle and has effects on our climate and weather systems. Water vapour affects the electromagnetic radiation through the atmosphere, which is of significance in fields of astronomy, radar, communications and remote sensing. Precipitable water vapor (PWV) is the amount of water obtained if all the water vapor in the atmosphere were to be compressed to the point at which it condenses into liquid. PWV is difficult to measure adequately due to its variable distribution both spatially and temporally. Most of the current techniques (e.g., radiosondes or satellites) are only available at few locations and not continuously (few observations per day at most). However, in the last decades, GPS observations have been proven to accurately measure the ZTD (Zenith Tropospheric Delay) at high frequencies (normally every 5 minutes) above the station. This quantity can be converted to PWV if temperature and pressure is know at the station location. In early 2004, King Abdulaziz City for Science and Technology (KACST) established a GPS network for geodetic and geophysical applications to contribute to the International GNSS Service IGS. In this study, we will present the first PWV measurements obtained from Global Navigation Satellite System GNSS receiver at the Solar Village (SOLA), 60 km from Riyadh. GNSS observations for the period between 2004-2006 are used to study the daily and seasonal variations of ZTD, and consequently of PWV in SOLA. In addition, we also compare the GNSS-derived PWV with sunphotometer and radiosonde estimates at SOLA in order to evaluate the compatibility of these techniques in a dry climate as the one in Riyadh.
Impact of seasonal and postglacial surface displacement on global reference frames
NASA Astrophysics Data System (ADS)
Krásná, Hana; Böhm, Johannes; King, Matt; Memin, Anthony; Shabala, Stanislav; Watson, Christopher
2014-05-01
The calculation of actual station positions requires several corrections which are partly recommended by the International Earth Rotation and Reference Systems Service (IERS) Conventions (e.g., solid Earth tides and ocean tidal loading) as well as other corrections, e.g. accounting for hydrology and atmospheric loading. To investigate the pattern of omitted non-linear seasonal motion we estimated empirical harmonic models for selected stations within a global solution of suitable Very Long Baseline Interferometry (VLBI) sessions as well as mean annual models by stacking yearly time series of station positions. To validate these models we compare them to displacement series obtained from the Gravity Recovery and Climate Experiment (GRACE) data and to hydrology corrections determined from global models. Furthermore, we assess the impact of the seasonal station motions on the celestial reference frame as well as on Earth orientation parameters derived from real and also artificial VLBI observations. In the second part of the presentation we apply vertical rates of the ICE-5G_VM2_2012 vertical land movement grid on vertical station velocities. We assess the impact of postglacial uplift on the variability in the scale given different sampling of the postglacial signal in time and hence on the uncertainty in the scale rate of the estimated terrestrial reference frame.
NASA Astrophysics Data System (ADS)
Kontny, B.; Grzempowski, P.; Bogusz, J.; Jarosinski, M.; Klos, A.
2012-12-01
Now it became obvious in the world literature that Cenozoic intraplate deformations of the Northwestern Eurasia were connected with the Alpine plate collision. However, relations of the Cenozoic intraplate deformations with the contemporary spreading in the north and transcontinental shears along the Tornquist line and Urals must be taken into account as well. On the contrary, in East Europe, periods of the activity being coincident with those in the Caucasus and the phases of the Red Sea opening. It is also evidence that the southern East European craton belongs to the Periarabian collision area. A compression axis orientation was sub latitudinal there, this allows suggestion that the deformations were originated under pressure of the adjacent Urals. According to some authors the present view of unity and rigidity of the Cenozoic Eurasian plate is correct only at the first approximation. In reality, the Eurasian plate represented a time varying kaleidoscope of sub plates that moved at different velocities from the Atlantic-Arctic spreading axis. Contemporary image of the intraplate deformation can be verified on the basis of observations of permanent stations GPS at present. Density the IGS and EPN station on the North-East Eurasian area isn't sufficient to the credible estimation of geokinematics parameters of every sub plates (platforms). But national networks of the GBAS stations, as for example a Polish network ASG-EUPOS, are ensuring the much higher density of measuring stations (average distance between stations of the c 70 km). Stations are located on both sides of the Teisseyre - Tornquist zone, both on East-European Precambrian platform (East European Craton) as well as on West-European Paleozoic platform. Three-year period of permanent GPS observation on ASG-EUPOS stations enabled the estimation of the velocities of the stations with the sufficing accuracy for the geodynamic purposes. It gave the possibility of the evaluation of contemporary rigidity of both of these platforms in the area of the reach the Polish ASG-EPOS network. The authors used CATREF to combine weekly SINEX (Solution Independent Exchange Format) files (results of GNSS data processing of the ASG-EUPOS network in BERNESE 5.0 software) with variance-covariance matrices in order to determine the cumulative solution (by means of coordinates and velocities). Estimated values of the horizontal velocities of the ASG-EUPOS stations in the ITRF2005 reference frame do not differ from the generally known model of the EURA plate movement. Differences with respect to other published results are seen at the level of the intraplate velocities and intraplate deformations. Compression deformations on the area of the Precambrian platform are reaching much considerable values than in the area of the Paleozoic platform. Also a distribution of directions of the maximum compressions is different. At the work an attempt of preliminary interpretation of these results was made.
Jain, Shikha; Shetty, K Sadashiva; Jain, Shweta; Jain, Sachin; Prakash, A T; Agrawal, Mamta
2015-07-01
To assess the null hypothesis that there is no difference in the rate of dental development and the occurrence of selected developmental anomalies related to shape, number, structure, and position of teeth between subjects with impacted mandibular canines and those with normally erupted canines. Pretreatment records of 42 subjects diagnosed with mandibular canines impaction (impaction group: IG) were compared with those of 84 subjects serving as a control reference sample (control group: CG). Independent t-tests were used to compare mean dental ages between the groups. Intergroup differences in distribution of subjects based on the rate of dental development and occurrence of selected dental anomalies were assessed using χ(2) tests. Odds of late, normal, and early developers and various categories of developmental anomalies between the IG and the CG were evaluated in terms of odds ratios. Mean dental age for the IG was lower than that for the CG in general. Specifically, this was true for girls (P < .05). Differences in the distribution of the subjects based on the rate of dental development and occurrence of positional anomalies also reached statistical significance (P < .05). The IG showed a higher frequency of late developers and positional anomalies compared with controls (odds ratios 3.00 and 2.82, respectively; P < .05). The null hypothesis was rejected. We identified close association of female subjects in the IG with retarded dental development compared with the female orthodontic patients. Increased frequency of positional developmental anomalies was also remarkable in the IG.
Pote, Kiran; Narang, Rahul; Deshmukh, Pradeep
2018-01-01
Differentiating scrub typhus from other acute febrile illness is difficult due to non specificity of clinical symptoms and relative absence of eschar in Indian population. The diagnosis thus relies mainly on laboratory tests. Antibody based serological tests are mainstay of scrub typhus diagnosis. Here, we evaluated the diagnostic performance of IgM ELISA, IgM IFA and ICT to detect antibodies against O. tsutsugamushi in acute serum of febrile patients. The serum samples from 600 randomly selected patients suffering from acute undifferentiated fever were tested by all the three tests mentioned above. We used latent class analysis to generate unbiased results as all the tests for scrub typhus diagnosis are imperfect and none of them can be considered as reference standard. We found that IgM ELISA with cutoff titer 0.5 OD has high diagnostic accuracy (sensitivity 99.9% and specificity 99.15) than IgM IFA (sensitivity 96.8% and specificity 99.7%) for scrub typhus diagnosis. ICT used in our study had very high specificity 100% but low sensitivity (38%) which would limit its use for acute serum samples. ICT being a screening or point of care test, has to be more sensitive while some compromise with specificity is affordable. Hence, optimal cutoff for ICT should be evaluated under different settings. IgM ELISA being simple and affordable could be an alternative diagnostic test to IgM IFA which is subjective and costly.
Teranishi, Junya; Yamamoto, Ryohei; Nagasawa, Yasuyuki; Shoji, Tatsuya; Iwatani, Hirotsugu; Okada, Noriyuki; Moriyama, Toshiki; Yamauchi, Atsushi; Tsubakihara, Yoshiharu; Imai, Enyu; Rakugi, Hiromi; Isaka, Yoshitaka
2015-09-01
Little is known about genetic predictors that modify the renoprotective effect of renin-angiotensin system (RAS) blockade in IgA nephropathy (IgAN). The present multicenter retrospective observational study examined effect modification between RAS blockade and three RAS-related gene polymorphisms in 237 IgAN patients, including ACE I/D (rs1799752), AT1R A1166C (rs5186) and AGT T704C (rs699). During 9.9 ± 4.2 years of observation, 63 patients progressed to a 50% increase in serum creatinine level. Only ACE I/D predicted the outcome (ACE DD vs ID/II, hazard ratio 1.86 (95% confidence interval 1.03, 3.33)) and modified the renoprotective effect of RAS blockade (p for interaction between ACE DD and RAS blockade = 0.087). RAS blockade suppressed progression in ACE DD patients but not in ID/II patients (ACE ID/II with RAS blockade as a reference; ID/II without RAS blockade 1.45 (0.72, 2.92); DD without RAS blockade 3.06 (1.39, 6.73); DD with RAS blockade 1.51 (0.54, 4.19)), which was ascertained in a model with the outcome of slope of estimated glomerular filtration rate (p = 0.045 for interaction). ACE I/D predicted the IgAN progression and the renoprotective effect of RAS blockade in IgAN patients whereas neither AT1R A1166C nor AGT T704C did. © The Author(s) 2014.
Indoor transformer stations as predictors of residential ELF magnetic field exposure.
Ilonen, K; Markkanen, A; Mezei, G; Juutilainen, Jukka
2008-04-01
Transformer stations in apartment buildings may offer a possibility to conduct epidemiological studies that involve high exposure to extremely low frequency magnetic fields (MF), avoid selection bias and minimize confounding factors. To validate exposure assessment based on transformer stations, measurements were performed in thirty buildings in three Finnish cities. In each building, spot measurements in all rooms and a 24-h recording in a bedroom were performed in one apartment above a transformer station (AAT), in one first floor (FF) reference apartment, and one reference apartment on upper floors (UF). The apartment mean of spot measurements was 0.62 microT in the AATs, 0.21 microT in the FF and 0.11 microT in the UF reference apartments The 24-h apartment mean (estimated from the spot measurements and the bedroom 24-h recording) was 0.2 microT or higher in 29 (97%) AATs, in 7 (25%) FF and in 3 (10 %) UF reference apartments. The corresponding numbers for the 0.4 microT cut-off point were 19 (63%), 4 (14%), and 1 (3.3%). The higher MF level in the FF reference apartments indicates that they should not be considered "unexposed" in epidemiological studies. If such apartments are excluded, a transformer station under the floor predicts 24-h apartment mean MF with a sensitivity of 0.41 (or 0.58) and a specificity of 0.997 (or 0.97), depending on the MF cut-off point (0.2 or 0.4 microT). The results indicate that apartments can be reliably classified as high and low MF field categories based on the known location of transformer stations. (c) 2007 Wiley-Liss, Inc.
A three-dimensional multivariate representation of atmospheric variability
NASA Astrophysics Data System (ADS)
Žagar, Nedjeljka; Jelić, Damjan; Blaauw, Marten; Jesenko, Blaž
2016-04-01
A recently developed MODES software has been applied to the ECMWF analyses and forecasts and to several reanalysis datasets to describe the global variability of the balanced and inertio-gravity (IG) circulation across many scales by considering both mass and wind field and the whole model depth. In particular, the IG spectrum, which has only recently become observable in global datasets, can be studied simultaneously in the mass field and wind field and considering the whole model depth. MODES is open-access software that performs the normal-mode function decomposition of the 3D global datasets. Its application to the ERA Interim dataset reveals several aspects of the large-scale circulation after it has been partitioned into the linearly balanced and IG components. The global energy distribution is dominated by the balanced energy while the IG modes contribute around 8% of the total wave energy. However, on subsynoptic scales IG energy dominates and it is associated with the main features of tropical variability on all scales. The presented energy distribution and features of the zonally-averaged and equatorial circulation provide a reference for the intercomparison of several reanalysis datasets and for the validation of climate models. Features of the global IG circulation are compared in ERA Interim, MERRA and JRA reanalysis datasets and in several CMIP5 models. Since October 2014 the operational medium-range forecasts of the European Centre for Medium-Range Weather Forecasts (ECMWF) have been analyzed by MODES daily and an online archive of all the outputs is available at http://meteo.fmf.uni-lj.si/MODES. New outputs are made available daily based on the 00 UTC run and subsequent 12-hour forecasts up to 240-hour forecast. In addition to the energy spectra and horizontal circulation on selected levels for the balanced and IG components, the equatorial Kelvin waves are presented in time and space as the most energetic tropical IG modes propagating vertically and along the equator from its main generation regions in the upper troposphere over the Indian and Pacific region. The validation of the 10-day ECMWF forecasts with analyses in the modal space suggests a lack of variability in the tropics in the medium range. Reference: Žagar, N. et al., 2015: Normal-mode function representation of global 3-D data sets: open-access software for the atmospheric research community. Geosci. Model Dev., 8, 1169-1195, doi:10.5194/gmd-8-1169-2015 Žagar, N., R. Buizza, and J. Tribbia, 2015: A three-dimensional multivariate modal analysis of atmospheric predictability with application to the ECMWF ensemble. J. Atmos. Sci., 72, 4423-4444 The MODES software is available from http://meteo.fmf.uni-lj.si/MODES.
Space Station Biological Research Project: Reference Experiment Book
NASA Technical Reports Server (NTRS)
Johnson, Catherine (Editor); Wade, Charles (Editor)
1996-01-01
The Space Station Biological Research Project (SSBRP), which is the combined efforts of the Centrifuge Facility (CF) and the Gravitational Biology Facility (GBF), is responsible for the development of life sciences hardware to be used on the International Space Station to support cell, developmental, and plant biology research. The SSBRP Reference Experiment Book was developed to use as a tool for guiding this development effort. The reference experiments characterize the research interests of the international scientific community and serve to identify the hardware capabilities and support equipment needed to support such research. The reference experiments also serve as a tool for understanding the operational aspects of conducting research on board the Space Station. This material was generated by the science community by way of their responses to reference experiment solicitation packages sent to them by SSBRP scientists. The solicitation process was executed in two phases. The first phase was completed in February of 1992 and the second phase completed in November of 1995. Representing these phases, the document is subdivided into a Section 1 and a Section 2. The reference experiments contained in this document are only representative microgravity experiments. They are not intended to define actual flight experiments. Ground and flight experiments will be selected through the formal NASA Research Announcement (NRA) and Announcement of Opportunity (AO) experiment solicitation, review, and selection process.
Automation of Precise Time Reference Stations (PTRS)
NASA Astrophysics Data System (ADS)
Wheeler, P. J.
1985-04-01
The U.S. Naval Observatory is presently engaged in a program of automating precise time stations (PTS) and precise time reference stations (PTBS) by using a versatile mini-computer controlled data acquisition system (DAS). The data acquisition system is configured to monitor locally available PTTI signals such as LORAN-C, OMEGA, and/or the Global Positioning System. In addition, the DAS performs local standard intercomparison. Computer telephone communications provide automatic data transfer to the Naval Observatory. Subsequently, after analysis of the data, results and information can be sent back to the precise time reference station to provide automatic control of remote station timing. The DAS configuration is designed around state of the art standard industrial high reliability modules. The system integration and software are standardized but allow considerable flexibility to satisfy special local requirements such as stability measurements, performance evaluation and printing of messages and certificates. The DAS operates completely independently and may be queried or controlled at any time with a computer or terminal device (control is protected for use by authorized personnel only). Such DAS equipped PTS are operational in Hawaii, California, Texas and Florida.
Chemical and biological assessment of two offshore drilling sites in the Alaskan Arctic.
Trefry, John H; Dunton, Kenneth H; Trocine, Robert P; Schonberg, Susan V; McTigue, Nathan D; Hersh, Eric S; McDonald, Thomas J
2013-05-01
A retrospective chemical and biological study was carried out in Camden Bay, Alaskan Beaufort Sea, where single exploratory oil wells were drilled at two sites more than two decades ago. Barium from discharged drilling mud was present in sediments at concentrations as high as 14%, ~200 times above background, with significantly higher concentrations of Ba, but not other metals, within 250 m of the drilling site versus reference stations. Elevated concentrations of Cr, Cu, Hg and Pb were found only at two stations within 25 m of one drilling site. Concentrations of total polycyclic aromatic hydrocarbons (TPAH) were not significantly different at reference versus drilling-site stations; however, TPAH were elevated in Ba-rich layers from naturally occurring perylene in ancient formation cuttings. Infaunal biomass and species abundance were not significantly different at reference versus drilling-site stations; infauna were less diverse at drilling-site stations. Our assessment showed that discharges from single wells within large areas caused minimal long-term, adverse impacts to the benthic ecosystem. Copyright © 2013 Elsevier Ltd. All rights reserved.
Position of the station Borowiec in the Doppler observation campaign WEDOC 80
NASA Astrophysics Data System (ADS)
Pachelski, W.
The position of the Doppler antenna located at the Borowiec Observatory, Poland, is analyzed based on data gathered during the WEDOC 80 study and an earlier study in 1977. Among other findings, it is determined that biases of the reference system origin can be partially eliminated by transforming absolute coordinates of two or more stations into station-to-station vector components, and by determining the vector length while the system scale remains affected by broadcast ephemerides. The standard deviations of absolute coordinates are shown to represent only the internal accuracy of the solution, and are found to depend on the geometrical configuration between the station position and the satellite passes. It is shown that significant correlations between station coordinates in translocation or multilocation are due to the poor conditioning of design matrices with respect to the origin and orientation of the reference system.
Sakaguchi, Kazuhiko; Hirota, Yushi; Hashimoto, Naoko; Ogawa, Wataru; Hamaguchi, Tomoya; Matsuo, Toshihiro; Miyagawa, Jun-ichiro; Namba, Mitsuyoshi; Sato, Toshiyuki; Okada, Seiki; Tomita, Koji; Matsuhisa, Munehide; Kaneto, Hideaki; Kosugi, Keisuke; Maegawa, Hiroshi; Nakajima, Hiromu; Kashiwagi, Atsunori
2013-05-01
We developed a system for measuring glucose area under the curve (AUC) using minimally invasive interstitial fluid extraction technology (MIET). Sweat contamination during interstitial fluid glucose (IG) extraction affects the accuracy of glucose AUC measurement, because this technology uses extracted sodium ion levels as an internal standard. Therefore, we developed a sweat monitoring patch to reduce this effect and investigated its efficacy in volunteers undergoing oral glucose tolerance tests (OGTTs). Fifty diabetes mellitus inpatients and 10 healthy subjects undergoing the 75 g OGTT were included. Two sites on the forearm were pretreated with microneedle arrays, then hydrogels for interstitial fluid extraction were placed on the treated sites. Simultaneously, hydrogels for sweat monitoring were placed on untreated sites near the treated sites. Plasma glucose (PG) levels were measured every 30 min for 2 h to calculate reference AUC values. Using MIET, IG AUC was calculated from extracted glucose and sodium ion levels after attachment of the hydrogel for 2 h. Good correlation between IG AUC measurements using MIET and reference AUCs measured using PG levels was confirmed over a wide AUC range (202-610 mg/h/dl) after correction for the sweat-induced error detected by the hydrogel patches on the nonpretreated skin. Strong correlation between IG AUC and peak glucose levels indicates that glucose spikes can be easily detected by this system. We confirmed the effectiveness of a sweat monitoring patch for precise AUC measurement using MIET. This novel, easy-to-use system has potential for glucose excursion evaluation in daily clinical practice. © 2013 Diabetes Technology Society.
Madrigal-Burgaleta, R; Berges-Gimeno, M P; Angel-Pereira, D; Ferreiro-Monteagudo, R; Guillen-Ponce, C; Pueyo, C; Gomez de Salazar, E; Alvarez-Cuesta, E
2013-07-01
Desensitization to antineoplastic agents is becoming a standard of care. Efforts to establish and improve these techniques are being made at many institutions. Our aims are to evaluate a new rapid desensitization protocol designed to be shorter (approximately 4 h) and safer (reducing hazardous drugs exposure risks) and to assess the oxaliplatin-specific immunoglobulin E (IgE) as a novel diagnostic tool. Prospective, observational, longitudinal study with patients who, for a 1-year period, suffered reactions to antineoplastic agents and were referred to the Desensitization Program at Ramon y Cajal University Hospital (RCUH). Patients were included or excluded as desensitization candidates after anamnesis, skin testing, risk assessment, and graded challenge. Specific IgE was determined in oxaliplatin-reactive patients. Candidate patients were desensitized using the new RCUH rapid desensitization protocol. Of 189 intravenous rapid desensitizations, 188 were successfully accomplished in the 23 patients who met inclusion criteria for desensitization (of 58 referred patients). No breakthrough reactions occurred in 94% of desensitizations, and most breakthrough reactions were mild. In 10 oxaliplatin-reactive patients, 38 desensitizations were successfully accomplished. Sensitivity for oxaliplatin-specific IgE was 38% (0.35UI/l cutoff point) and 54% (0.10UI/l cutoff point); specificity was 100% for both cutoff points. In the hands of a Desensitization Program, managed by drug desensitization experts, this new protocol has proven an effective therapeutic tool for hypersensitivity to several antineoplastic agents (oxaliplatin, carboplatin, paclitaxel, docetaxel, cyclophosphamide, and rituximab); moreover, it improves safety handling of hazardous drugs. We report the first large series of oxaliplatin desensitizations. Oxaliplatin-specific IgE determination could be helpful. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Sakaguchi, Kazuhiko; Hirota, Yushi; Hashimoto, Naoko; Ogawa, Wataru; Hamaguchi, Tomoya; Toshihiro, Matsuo; Miyagawa, Jun-ichiro; Namba, Mitsuyoshi; Sato, Toshiyuki; Okada, Seiki; Tomita, Koji; Matsuhisa, Munehide; Kaneto, Hideaki; Kosugi, Keisuke; Maegawa, Hiroshi; Nakajima, Hiromu; Kashiwagi, Atsunori
2013-01-01
Aims: We developed a system for measuring glucose area under the curve (AUC) using minimally invasive interstitial fluid extraction technology (MIET). Sweat contamination during interstitial fluid glucose (IG) extraction affects the accuracy of glucose AUC measurement, because this technology uses extracted sodium ion levels as an internal standard. Therefore, we developed a sweat monitoring patch to reduce this effect and investigated its efficacy in volunteers undergoing oral glucose tolerance tests (OGTTs). Materials and Methods: Fifty diabetes mellitus inpatients and 10 healthy subjects undergoing the 75 g OGTT were included. Two sites on the forearm were pretreated with microneedle arrays, then hydrogels for interstitial fluid extraction were placed on the treated sites. Simultaneously, hydrogels for sweat monitoring were placed on untreated sites near the treated sites. Plasma glucose (PG) levels were measured every 30 min for 2 h to calculate reference AUC values. Using MIET, IG AUC was calculated from extracted glucose and sodium ion levels after attachment of the hydrogel for 2 h. Results: Good correlation between IG AUC measurements using MIET and reference AUCs measured using PG levels was confirmed over a wide AUC range (202–610 mg/h/dl) after correction for the sweat-induced error detected by the hydrogel patches on the nonpretreated skin. Strong correlation between IG AUC and peak glucose levels indicates that glucose spikes can be easily detected by this system. Conclusion: We confirmed the effectiveness of a sweat monitoring patch for precise AUC measurement using MIET. This novel, easy-to-use system has potential for glucose excursion evaluation in daily clinical practice. PMID:23759401
NASA Astrophysics Data System (ADS)
Gu, Yanchao; Fan, Dongming; You, Wei
2017-07-01
Eleven GPS crustal vertical displacement (CVD) solutions for 110 IGS08/IGS14 core stations provided by the International Global Navigation Satellite Systems Service Analysis Centers are compared with seven Gravity Recovery and Climate Experiment (GRACE)-modeled CVD solutions. The results of the internal comparison of the GPS solutions from multiple institutions imply large uncertainty in the GPS postprocessing. There is also evidence that GRACE solutions from both different institutions and different processing approaches (mascon and traditional spherical harmonic coefficients) show similar results, suggesting that GRACE can provide CVD results of good internal consistency. When the uncertainty of the GPS data is accounted for, the GRACE data can explain as much as 50% of the actual signals and more than 80% of the GPS annual signals. Our study strongly indicates that GRACE data have great potential to correct the nontidal loading in GPS time series.
Schampera, Matthias Stefan; Schweinzer, Katrin; Abele, Harald; Kagan, Karl Oliver; Klein, Reinhild; Rettig, Ingo; Jahn, Gerhard; Hamprecht, Klaus
2017-05-01
Based on a non-randomized study of Nigro et al. (2005) the intravenous administration of hyperimmunoglobulins (HIGs) is applied frequently to women with primary CMV-infection as "off-label use" in Germany. In order to describe their CMV-specific neutralization-capacity in vitro, we analyzed the HIG preparations Cytotect ® , and Cytogam ® as well as the standard intravenous immunoglobulins (IVIG) Octagam ® , Gamunex ® , Kiovig ® . We performed short-term cell-free CMV neutralization assays (CFNT) and long-term cell-adapted neutralization-plaque-reduction assays (PRANT). Human retinal epithelial cells (ARPE-19) were used as target cells. A clinical CMV primary-isolate from amnion fluid propagated in epithelial cells without any initial fibroblast adaption was used. For calibration we previously generated serum-pools (N=100) from two cohorts of mothers at birth: seronegative and latently CMV-infected mothers. Biochemical analysis included total protein, albumin, Ig-class, and IgG-subclasses. Additionally, CMV antibody-reactivity was checked using recombinant immunoblotting. HIG and IVIG preparations showed differences in levels and patterns of protein, Ig-class and CMV-specific antibody concentrations. All IgG-preparations showed high in vitro NT-capacity and high IgG-avidity. The NT 90 -values for HIGs and IVIGs and our seropositive reference-pool showed similar NT-capacity at a dilution of (1:100) which corresponded well to 4.1 PEI-Units/ml. All HIG- and IVIG-preparations showed similar NT-capacity following CMV IgG-normalization. Our in vitro results are in strong contrast to former findings suggesting higher functional CMV NT titers in IVIG-preparations compared to HIGs. Copyright © 2017 Elsevier B.V. All rights reserved.
Kuehr, Joachim; Brauburger, Jens; Zielen, Stefan; Schauer, Uwe; Kamin, Wolfgang; Von Berg, Andrea; Leupold, Wolfgang; Bergmann, Karl-Christian; Rolinck-Werninghaus, Claudia; Gräve, Michael; Hultsch, Thomas; Wahn, Ulrich
2002-02-01
Specific immunotherapy (SIT) and treatment with monoclonal anti-IgE antibody have complementary modes of action. The purpose of this study was to determine whether combined therapy could provide better efficacy than either treatment alone. We conducted a randomized, double-blinded trial to assess the efficacy and safety of subcutaneously administered anti-IgE (omalizumab) or placebo in children and adolescents with seasonal allergic rhinitis in both a birch pollen season and a grass pollen season (sequential seasons together lasting an average of 84 days). There were 4 treatment arms. Each subject was started on SIT-birch or SIT-grass, and anti-IgE or placebo was started before and maintained during the anticipated pollen seasons (a total of 24 weeks). The primary efficacy variable was symptom load, the sum of daily symptom severity score plus rescue medication use. A total of 221 subjects (intent-to-treat population) aged 6 to 17 years were analyzed for efficacy. Combination therapy reduced symptom load over the 2 pollen seasons by 48% (P <.001) over SIT alone. When analyzed separately by season, the 2 groups receiving unrelated SIT were considered placebo controls. In the grass season, symptom loads were as follows: unrelated (birch) SIT + placebo, 0.89 (reference value); unrelated (birch) SIT + anti-IgE, 0.49 (-45%); SIT-grass + placebo, 0.61 (-32%); SIT-grass + anti-IgE, 0.26 (-71%). Anti-IgE therapy conferred a protective effect independent of the type of allergen. Additional clinical benefit was demonstrated in both pollen seasons, whether there was coverage by SIT or not. This combination might prove useful for the treatment of allergic rhinitis, particularly for polysensitized patients.
Rodríguez Lay, Licel de los Angeles; Quintana, Ariel; Villalba, María Caridad Montalvo; Lemos, Gilda; Corredor, Marité Bello; Moreno, Aidonis Gutiérrez; Prieto, Pablo Aguiar; Guzmán, María G; Anderson, David
2008-05-01
Viral hepatitis ranks as the fifth cause of morbidity for infectious diseases in Cuba. Epidemics are observed frequently in the population, the hepatitis A virus being the main agent responsible for such epidemics. Previous reports also confirmed the circulation of the hepatitis E virus. From 1998 to 2003, 258 serum samples were collected by the Reference Laboratory on Viral Hepatitis during 33 outbreaks of acute viral hepatitis as well as from 39 sporadic clinical cases. Sera were tested for anti-HAV and anti-HEV IgM by EIA. Overall of the 33 outbreaks studied sera from 12 (36.4%) were positive for anti-HAV IgM only, from 7 (21.2%) were positive for anti-HEV IgM only, and from 14 (42.4%) were positive for antibodies to both viruses. Individually of the 258 sera collected, 137 (53.1%) were positives for anti-HAV IgM, 20 (7.8%) were positives for anti-HEV IgM, 33 (12.8%) were positives for both markers and 68 (26.4%) were negative to both. Of the clinical cases, 4 (10.3%) were positives for anti-HAV IgM, 13 (33.3%) were positives for anti-HEV IgM and 5 (12.8%) were positives for both markers. Seventeen (43.6%) sera were negatives for all viral hepatitis markers available (A-E). A high positivity for HEV was found in outbreaks tested with the kit produced by CIGB. In particular HEV seems to infect individuals of all ages. The results demonstrate the co-circulation of and co-infection with two enterically transmitted viruses; however a higher positivity was observed for anti-HAV than to anti-HEV (53.1% vs. 7.8%) in outbreaks.
Highly sensitive and unbiased approach for elucidating antibody repertoires
Lin, Sherry G.; Ba, Zhaoqing; Du, Zhou; Zhang, Yu; Hu, Jiazhi; Alt, Frederick W.
2016-01-01
Developing B lymphocytes undergo V(D)J recombination to assemble germ-line V, D, and J gene segments into exons that encode the antigen-binding variable region of Ig heavy (H) and light (L) chains. IgH and IgL chains associate to form the B-cell receptor (BCR), which, upon antigen binding, activates B cells to secrete BCR as an antibody. Each of the huge number of clonally independent B cells expresses a unique set of IgH and IgL variable regions. The ability of V(D)J recombination to generate vast primary B-cell repertoires results from a combinatorial assortment of large numbers of different V, D, and J segments, coupled with diversification of the junctions between them to generate the complementary determining region 3 (CDR3) for antigen contact. Approaches to evaluate in depth the content of primary antibody repertoires and, ultimately, to study how they are further molded by secondary mutation and affinity maturation processes are of great importance to the B-cell development, vaccine, and antibody fields. We now describe an unbiased, sensitive, and readily accessible assay, referred to as high-throughput genome-wide translocation sequencing-adapted repertoire sequencing (HTGTS-Rep-seq), to quantify antibody repertoires. HTGTS-Rep-seq quantitatively identifies the vast majority of IgH and IgL V(D)J exons, including their unique CDR3 sequences, from progenitor and mature mouse B lineage cells via the use of specific J primers. HTGTS-Rep-seq also accurately quantifies DJH intermediates and V(D)J exons in either productive or nonproductive configurations. HTGTS-Rep-seq should be useful for studies of human samples, including clonal B-cell expansions, and also for following antibody affinity maturation processes. PMID:27354528
Elsohaby, Ibrahim; Hou, Siyuan; McClure, J Trenton; Riley, Christopher B; Shaw, R Anthony; Keefe, Gregory P
2015-08-20
Following the recent development of a new approach to quantitative analysis of IgG concentrations in bovine serum using transmission infrared spectroscopy, the potential to measure IgG levels using technology and a device better designed for field use was investigated. A method using attenuated total reflectance infrared (ATR) spectroscopy in combination with partial least squares (PLS) regression was developed to measure bovine serum IgG concentrations. ATR spectroscopy has a distinct ease-of-use advantage that may open the door to routine point-of-care testing. Serum samples were collected from calves and adult cows, tested by a reference RID method, and ATR spectra acquired. The spectra were linked to the RID-IgG concentrations and then randomly split into two sets: calibration and prediction. The calibration set was used to build a calibration model, while the prediction set was used to assess the predictive performance and accuracy of the final model. The procedure was repeated for various spectral data preprocessing approaches. For the prediction set, the Pearson's and concordance correlation coefficients between the IgG measured by RID and predicted by ATR spectroscopy were both 0.93. The Bland Altman plot revealed no obvious systematic bias between the two methods. ATR spectroscopy showed a sensitivity for detection of failure of transfer of passive immunity (FTPI) of 88 %, specificity of 100 % and accuracy of 94 % (with IgG <1000 mg/dL as the FTPI cut-off value). ATR spectroscopy in combination with multivariate data analysis shows potential as an alternative approach for rapid quantification of IgG concentrations in bovine serum and the diagnosis of FTPI in calves.
Sunyer, J. Oriol
2012-01-01
The evolutionary origins of Ig-producing B cells appear to be linked to the emergence of fish in this planet. There are three major classes of living fish species, which from most primitive to modern they are referred to as agnathan (e.g., lampreys), Chondrichthyes (e.g., sharks), and teleost fish (e.g., rainbow trout). Agnathans do not have immunoglobulin-producing B cells, however these fish contain a subset of lymphocytes-like cells producing type B variable lymphocyte receptors (VLRBs) that appear to act as functional analogs of immunoglobulins. Chondrichthyes fish represent the most primitive living species containing bona-fide immunoglobulin-producing B cells. Their B cells are known to secrete three types of antibodies, IgM, IgW and IgNAR. Teleost fish are also called bony fish since they represent the most ancient living species containing true bones. Teleost B cells produce three different immunoglobulin isotypes, IgM, IgD and the recently described IgT. While teleost IgM is the principal player in systemic immunity, IgT appears to be a teleost immunoglobulin class specialized in mucosal immune responses. Thus far, three major B cell lineages have been described in teleost, those expressing either IgT or IgD, and the most common lineage which co-expresses IgD and IgM. A few years ago, the study of teleost fish B cells revealed for the first time in vertebrates the existence of B cell subsets with phagocytic and intracellular bactericidal capacities. This finding represented a paradigm shift as professional phagocytosis was believed to be exclusively performed by some cells of the myeloid lineage (i.e., macrophages, monocytes, neutrophils). This phagocytic capacity was also found in amphibians and reptiles, suggesting that this innate capacity was evolutionarily conserved in certain B cell subsets of vertebrates. Recently, the existence of subsets of B cells with phagocytic and bactericidal abilities have also been confirmed in mammals. Moreover, it has been shown that phagocytic B-1 B cells have a potent ability to present particulate antigen to CD4+ T cells. Thus, studies carried out originally on fish B cells have lead to the discovery of new innate and adaptive roles of B cells in mammals. This review will concentrate on the evolutionary and functional relationships of fish and mammalian B cells, focusing mainly on the newly discovered roles of these cells in phagocytosis, intracellular killing and presentation of particulate antigen. PMID:22394174
Marsden, A D; DeWreede, R E
2000-12-01
Marine macroalgal communities were examined near the outflow of acid mine drainage (AMD) from the Britannia Mine, British Columbia, Canada. No marine algae were present within 100 m of the mouth of Britannia Creek, which carries the AMD into the marine environment. At greater distances (300-700 m) from this Creek, mean summer cover of filamentous green algae, mostly Enteromorpha intestinalis, was >60%, which was significantly higher than at nearby reference stations. At still greater distances (600-1000 m) from Britannia Creek, Fucus gardneri dominated algal communities that were similar to those at reference stations. No consistent differences were detected in mean plant length, mean per cent cover or mean oocyte production between F. gardneri near Britannia Creek and those at reference stations. Cu body burden in F. gardneri near Britannia Creek was five to 17 times higher than in reference plants.
Gao, Qin-Feng; Cheung, Kwok-Leung; Cheung, Siu-Gin; Shin, Paul K S
2005-01-01
To study the correlation between nutrient enrichment derived from fish farming activities and changes in macrobenthic assemblages, a one-year field study was conducted in Kau Sai Bay marine fish culture zone of Hong Kong. Bimonthly sediment samples were collected at six stations: two at the fish cages, two near the boundary of the fish culture area, and two reference sites further away from the culture area. Sediment physico-chemical characteristics in terms of silt/clay fraction, moisture content, total organic carbon (TOC), total Kjeldahl nitrogen (TKN) and total phosphorus (TP) were analyzed. The macrobenthos (>0.5 mm) present in the sediment were sorted, identified and enumerated. On average, TOC, TKN and TP levels at the fish cage stations were 82.8%, 128.5% and 1315.7% higher than those at the reference stations, respectively. As a result, the N:P molar ratio was greatly reduced from 8.75 at the reference stations to 1.83 at the fish cage stations. Univariate and multivariate analyses revealed that diversity of macrofauna was significantly reduced and community structure differed at the fish cage stations relative to the reference sites. The intermediary stations near the fish culture area showed a transitional state of disturbance. Faunal diversity was negatively correlated with nutrient level, reflecting the adverse impacts of nutrient enrichment derived from fish farming activities on the benthic assemblages. Whilst in subtropical Asia-Pacific trash fish is the major feed for fish culture resulting in a higher nutrient loading and nutrient ratio accumulated in the sediment beneath the fish rafts, the effects of nutrient enrichment on macrobenthic assemblages are comparable to that in temperate waters owing to relatively high sediment metabolism rate and smaller fish culture scale in Hong Kong.
Moussa, Sandrine; Jenabian, Mohammad-Ali; Gody, Jean Chrysostome; Léal, Josiane; Grésenguet, Gérard; Le Faou, Alain; Bélec, Laurent
2013-01-01
Background We evaluated whether B cell-derived immune defenses of the gastro-intestinal tract are activated to produce HIV-specific antibodies in children continuously exposed to HIV via breast-feeding. Methods Couples of HIV-1-infected mothers (n = 14) and their breastfed non HIV-infected (n = 8) and HIV-infected (n = 6) babies, and healthy HIV-negative mothers and breastfed babies (n = 10) as controls, were prospectively included at the Complexe Pédiatrique of Bangui, Central African Republic. Immunoglobulins (IgA, IgG and IgM) and anti-gp160 antibodies from mother’s milk and stools of breastfed children were quantified by ELISA. Immunoaffinity purified anti-gp160 antibodies were characterized functionally regarding their capacity to reduce attachment and/or infection of R5- and X4- tropic HIV-1 strains on human colorectal epithelial HT29 cells line or monocyte-derived-macrophages (MDM). Results The levels of total IgA and IgG were increased in milk of HIV-infected mothers and stools of HIV-exposed children, indicating the activation of B cell-derived mucosal immunity. Breast milk samples as well as stool samples from HIV-negative and HIV-infected babies exposed to HIV by breast-feeding, contained high levels of HIV-specific antibodies, mainly IgG antibodies, less frequently IgA antibodies, and rarely IgM antibodies. Relative ratios of excretion by reference to lactoferrin calculated for HIV-specific IgA, IgG and IgM in stools of HIV-exposed children were largely superior to 1, indicating active production of HIV-specific antibodies by the intestinal mucosa. Antibodies to gp160 purified from pooled stools of HIV-exposed breastfed children inhibited the attachment of HIV-1NDK on HT29 cells by 63% and on MDM by 77%, and the attachment of HIV-1JRCSF on MDM by 40%; and the infection of MDM by HIV-1JRCSF by 93%. Conclusions The intestinal mucosa of children exposed to HIV by breast-feeding produces HIV-specific antibodies harbouring in vitro major functional properties against HIV. These observations lay the conceptual basis for the design of a prophylactic vaccine against HIV in exposed children. PMID:23704905
GNSS in real-time: Demonstration experiment at Berlin Airport International
NASA Astrophysics Data System (ADS)
Wickert, Jens; Dick, Galina; Ge, Maorong; Heise, Stefan; Li, XingXing; Ming, Shangguan; Nischan, Thomas; Ramatschi, Markus; Schuh, Harald; Alberding, Jürgen; Weigmann, Uwe
2013-04-01
Real-time (RT) applications are in focus of recent GNSS research. International activities related to the RT data collection and distribution, as well as provision of specific RT data products (e.g., satellite orbits and clocks, station coordinates) are coordinated within the Real-Time Project of the International GNSS Service (IGS). Currently IGS provides real-time data from more than 100 globally distributed GNSS ground stations. This number, in parallel with the extension of various additional international real-time networks, is continuously increasing. In parallel to the rapid development of GNSS RT activities also innovative geophysical applications were pioneered by GNSS research groups and institutions, including GFZ. One prominent example is the use of GNSS components in early warning systems. GNSS measurements can be used there for the rapid detection and characterization of deformation fields, related to earthquakes, which induce Tsunamis. Such deformation data cannot be provided by seismometer measurements, but are important for the prediction of the tsunami wave propagation caused by earthquakes. The GNSS real-time group at GFZ is involved in several research projects related to geophysical RT GNSS applications, and also operates one of the RT analysis centers of the IGS. We introduce results of a real-time GNSS demonstration project, which was performed in 2012 at the new Berlin International Airport BER at Schönefeld, south-east of Berlin city center. The main goal of the project was the demonstration of the functionality of a complex RT-PPP server-client solution for dynamic applications which was developed within a joint research project of GFZ and the company Alberding GmbH. Compared to the standard PPP (clock & orbit) this solution uses additional information (ionosphere, uncalibrated phase delays UPD) to increase the positioning accuracy and to reduce the convergence time. The major challenges of the experiment were the stable operation of the entire server-client system, the implementation of a mainly for scientific purposes developed software to a potentially commercial positioning solution, the real-time GNSS data management, and the generation and usage of the correction data. We evaluate the server-client system functionality and PPP results of the experiment in view of the project goals and indicate problems to be focused in future work. In addition, the GNSS data from a temporary ground station at the air-field was used to derive vertically integrated water vapor (IWV) data to demonstrate the potential of real-time water vapor data to improve the weather forecast at the airport. The IWV data are compared with measurements from nearby stations of the permanent German GNSS network for atmosphere sounding and with a water vapor radiometer, operated at GFZ.
Broger, Tobias; Basu Roy, Robindra; Filomena, Angela; Greef, Charles H; Rimmele, Stefanie; Havumaki, Joshua; Danks, David; Schneiderhan-Marra, Nicole; Gray, Christen M; Singh, Mahavir; Rosenkrands, Ida; Andersen, Peter; Husar, Gregory M; Joos, Thomas O; Gennaro, Maria L; Lochhead, Michael J; Denkinger, Claudia M; Perkins, Mark D
2017-04-01
Development of rapid diagnostic tests for tuberculosis is a global priority. A whole proteome screen identified Mycobacterium tuberculosis antigens associated with serological responses in tuberculosis patients. We used World Health Organization (WHO) target product profile (TPP) criteria for a detection test and triage test to evaluate these antigens. Consecutive patients presenting to microscopy centers and district hospitals in Peru and to outpatient clinics at a tuberculosis reference center in Vietnam were recruited. We tested blood samples from 755 HIV-uninfected adults with presumptive pulmonary tuberculosis to measure IgG antibody responses to 57 M. tuberculosis antigens using a field-based multiplexed serological assay and a 132-antigen bead-based reference assay. We evaluated single antigen performance and models of all possible 3-antigen combinations and multiantigen combinations. Three-antigen and multiantigen models performed similarly and were superior to single antigens. With specificity set at 90% for a detection test, the best sensitivity of a 3-antigen model was 35% (95% confidence interval [CI], 31-40). With sensitivity set at 85% for a triage test, the specificity of the best 3-antigen model was 34% (95% CI, 29-40). The reference assay also did not meet study targets. Antigen performance differed significantly between the study sites for 7/22 of the best-performing antigens. Although M. tuberculosis antigens were recognized by the IgG response during tuberculosis, no single antigen or multiantigen set performance approached WHO TPP criteria for clinical utility among HIV-uninfected adults with presumed tuberculosis in high-volume, urban settings in tuberculosis-endemic countries. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.
Heidebrecht, Hans-Jürgen; Toro-Sierra, José; Kulozik, Ulrich
2018-06-28
The use of bioactive bovine milk immunoglobulins (Ig) has been found to be an alternative treatment for certain human gastrointestinal diseases. Some methodologies have been developed with bovine colostrum. These are considered in laboratory scale and are bound to high cost and limited availability of the raw material. The main challenge remains in obtaining high amounts of active IgG from an available source as mature cow milk by the means of industrial processes. Microfiltration (MF) was chosen as a process variant, which enables a gentle and effective concentration of the Ig fractions (ca. 0.06% in raw milk) while reducing casein and lactose at the same time. Different microfiltration membranes (ceramic standard and gradient), pore sizes (0.14⁻0.8 µm), transmembrane pressures (0.5⁻2.5 bar), and temperatures (10, 50 °C) were investigated. The transmission of immunoglobulin G (IgG) and casein during the filtration of raw skim milk (<0.1% fat) was evaluated during batch filtration using a single channel pilot plant. The transmission levels of IgG (~160 kDa) were measured to be at the same level as the reference major whey protein β-Lg (~18 kDa) at all evaluated pore sizes and process parameters despite the large difference in molecular mass of both fractions. Ceramic gradient membranes with a pore sizes of 0.14 µm showed IgG-transmission rates between 45% to 65% while reducing the casein fraction below 1% in the permeates. Contrary to the expectations, a lower pore size of 0.14 µm yielded fluxes up to 35% higher than 0.2 µm MF membranes. It was found that low transmembrane pressures benefit the Ig transmission. Upscaling the presented results to a continuous MF membrane process offers new possibilities for the production of immunoglobulin enriched supplements with well-known processing equipment for large scale milk protein fractionation.
Mueller, Ralf S; Olivry, Thierry
2017-08-30
The gold standard to diagnose adverse food reactions (AFRs) in the dog and cat is currently an elimination diet with subsequent provocation trials. However, those trials are inconvenient and client compliance can be low. Our objective was to systematically review the literature to evaluate in vivo and in vitro tests used to diagnose AFR in small animals. We searched three databases (CAB Abstracts, MEDLINE and Web of Science) for pertinent references on September 16, 2016. Among 71, 544 and 41 articles found in the CAB Abstract, MEDLINE and Web of Science databases, respectively, we selected 22 articles and abstracts from conference proceedings that reported data usable for evaluation of tests for AFR. Serum tests for food-specific IgE and IgG, intradermal testing with food antigens, lymphocyte proliferation tests, fecal food-specific IgE, patch, gastroscopic, and colonoscopic testing were evaluated. Testing for serum food-specific IgE and IgG showed low repeatability and, in dogs, a highly variable accuracy. In cats, the accuracy of testing for food-specific IgE was low. Lymphocyte proliferation tests were more frequently positive and more accurate in animals with AFR, but, as they are more difficult to perform, they remain currently a research tool. All other reported tests were only evaluated by individual studies with small numbers of animals. Negative patch test reactions have a very high negative predictability in dogs and could enable a choice of ingredients for the elimination diet in selected patients. Gastroscopic and colonoscopic testing as well as food-specific fecal IgE or food-specific serum IgG measurements appear less useful. Currently, the best diagnostic procedure to identify AFRs in small animals remains an elimination diet with subsequent provocation trials.
Jaskowski, Troy D; La'ulu, Sonia L; Mahler, Michael; Tebo, Anne E
2017-09-01
We investigated the performance of an ELISA for the detection of 3-hydroxy-3-methyl-glutaryl-coenzyme A reductase (HMGCR) IgG antibodies in immune-mediated necrotizing myopathies (IMNM). Patients positive for HMGCR antibodies (n=61) or negative (n=78) by protein immunoprecipitation (IP), and healthy controls (n=100) were used to evaluate the ELISA. Unique consecutive serum samples (n=155) received at ARUP Laboratories for HMGCR IgG testing by ELISA were also investigated and analysed for serum muscle enzymes (aldolase, creatine kinase, and myoglobin). The ELISA's sensitivity, specificity, and percentage agreement were assessed relative to IP. Correlation between specific muscle enzyme concentration and the presence of HMGCR antibody was determined. Overall agreement between ELISA and IP was 93.4%. Using the IP as reference, the sensitivity and specificity of the ELISA was 95.1%, and 100%, respectively. Inter- and intra-assay coefficient of variation of the ELISA was <10.0%, and ≤15.0%, respectively. In the consecutive cohort, 21 (13.6%) samples tested positive for HMGCR IgG. Concentrations of aldolase, creatine kinase, and myoglobin were significantly higher (all p<0.0001) in patients positive for HMGCR antibodies at the time of evaluation. We confirm significant reliability of HMGCR antibodies as measured by the ELISA for the evaluation of IMNM. Copyright © 2017 Elsevier B.V. All rights reserved.
Function, form, and technology - The evolution of Space Station in NASA
NASA Technical Reports Server (NTRS)
Fries, S. D.
1985-01-01
The history of major Space Station designs over the last twenty-five years is reviewed. The evolution of design concepts is analyzed with respect to the changing functions of Space Stations; and available or anticipated technology capabilities. Emphasis is given to the current NASA Space Station reference configuration, the 'power tower'. Detailed schematic drawings of the different Space Station designs are provided.
Generation of helical Ince-Gaussian beams: beam-shaping with a liquid crystal display
NASA Astrophysics Data System (ADS)
Davis, Jeffrey A.; Bentley, Joel B.; Bandres, Miguel A.; Gutiérrez-Vega, Julio C.
2006-08-01
We review the three types of laser beams - Hermite-Gaussian (HG), Laguerre-Gaussian (LG) and the newly discovered Ince-Gaussian (IG) beams. We discuss the helical forms of the LG and IG beams that consist of linear combinations of the even and odd solutions and form a number of vortices that are useful for optical trapping applications. We discuss how to generate these beams by encoding the desired amplitude and phase onto a single parallel-aligned liquid crystal display (LCD). We introduce a novel interference technique where we generate both the object and reference beams using a single LCD and show the vortex interference patterns.
The Foundation GPS Water Vapor Inversion and its Application Research
NASA Astrophysics Data System (ADS)
Liu, R.; Lee, T.; Lv, H.; Fan, C.; Liu, Q.
2018-04-01
Using GPS technology to retrieve atmospheric water vapor is a new water vapor detection method, which can effectively compensate for the shortcomings of conventional water vapor detection methods, to provide high-precision, large-capacity, near real-time water vapor information. In-depth study of ground-based GPS detection of atmospheric water vapor technology aims to further improve the accuracy and practicability of GPS inversion of water vapor and to explore its ability to detect atmospheric water vapor information to better serve the meteorological services. In this paper, the influence of the setting parameters of initial station coordinates, satellite ephemeris and solution observation on the total delay accuracy of the tropospheric zenith is discussed based on the observed data. In this paper, the observations obtained from the observation network consisting of 8 IGS stations in China in June 2013 are used to inverse the water vapor data of the 8 stations. The data of Wuhan station is further selected and compared with the data of Nanhu Sounding Station in Wuhan The error between the two data was between -6mm-6mm, and the trend of the two was almost the same, the correlation reached 95.8 %. The experimental results also verify the reliability of ground-based GPS inversion of water vapor technology.
Lanshoeft, Christian; Wolf, Thierry; Walles, Markus; Barteau, Samuel; Picard, Franck; Kretz, Olivier; Cianférani, Sarah; Heudi, Olivier
2016-11-30
An increasing demand of new analytical methods is associated with the growing number of biotherapeutic programs being prosecuted in the pharmaceutical industry. Whilst immunoassay has been the standard method for decades, a great interest in assays based on liquid chromatography tandem mass spectrometry (LC-MS/MS) is evolving. In this present work, the development of a generic method for the quantitative analysis of therapeutic proteins based on human immunoglobulin G (hIgG) in rat serum is reported. The method is based on four generic peptides GPSVFPLAPSSK (GPS), TTPPVLDSDGSFFLYSK (TTP), VVSVLTVLHQDWLNGK (VVS) and FNWYVDGVEVHNAK (FNW) originating from different parts of the fraction crystallizable (Fc) region of a reference hIgG1 (hIgG1A). A tryptic pellet digestion of rat serum spiked with hIgG1A and a stable isotope labeled protein (hIgG1B) used as internal standard (ISTD) was applied prior LC-MS/MS analysis. The upper limit of quantification was at 1000μg/mL. The lower limit of quantitation was for GPS, TTP and VVS at 1.00μg/mL whereas for FNW at 5.00μg/mL. Accuracy and precision data met acceptance over three days. The presented method was further successfully applied to the quantitative analysis of other hIgG1s (hIgG1C and hIgG1D) and hIgG4-based therapeutic proteins on spiked quality control (QC) samples in monkey and rat serum using calibration standards (Cs) prepared with hIgG1A in rat serum. In order to extend the applicability of our generic approach, a bispecific-bivalent hIgG1 (bb-hIgG1) and two lysine conjugated antibody-drug conjugates (ADC1 and ADC2) were incorporated as well. The observed values on spiked QC samples in monkey serum were satisfactory with GPS for the determination of bb-hIgG1 whereas the FNW and TTP peptides were suitable for the ADCs. Moreover, comparable mean concentration-time profiles were obtained from monkeys previously dosed intravenously with ADC2 measured against Cs samples prepared either with hIgG1A in rat serum (presented approach) or with the actual ADC2 in monkey serum (conventional approach). The results of this study highlight the great flexibility of our newly developed generic approach and that the choice of the surrogate peptide still remains critical when dealing with different matrix types or modalities. Copyright © 2016 Elsevier B.V. All rights reserved.
Landsat International Cooperators and Global Archive Consolidation
,
2016-04-07
Landsat missions have always been an important component of U.S. foreign policy, as well as science and technology policy. The program’s longstanding network of International Cooperators (ICs), which operate numerous International Ground Stations (IGS) around the world, embodies the United States’ policy of peaceful use of outer space and the worldwide dissemination of civil space technology for public benefit. Thus, the ICs provide an essential dimension to the Landsat mission.In 2010, the Landsat Global Archive Consolidation (LGAC) effort began, with a goal to consolidate the Landsat data archives of all international ground stations, make the data more accessible to the global Landsat community, and significantly increase the frequency of observations over a given area of interest to improve scientific uses such as change detection and analysis.
Villard, O; Cimon, B; L'Ollivier, C; Fricker-Hidalgo, H; Godineau, N; Houze, S; Paris, L; Pelloux, H; Villena, I; Candolfi, E
2016-01-01
Toxoplasmosis manifests no clinical signs in 80% of cases in immunocompetent patient, causing immunization characterized by the persistence of cysts, particularly in brain, muscles, and retina. Assessing the serological status, based on testing for serum toxoplasma IgG and IgM antibodies, is essential in cases that are increasingly at risk for the more severe disease forms, such as congenital or ocular toxoplasmosis. This disease also exposes immunosuppressed patients to reactivation, which can lead to more widespread forms and increased mortality. By interpreting the serological results, we can estimate the risk of contamination or reactivation and define appropriate prophylactic and preventive measures, such as hygienic and dietetic, therapeutic, biological, and clinical follow-up, according to the clinical context. We hereby propose practical approaches based on serological data, resulting from a consensus of a group of experts from the French National Reference Center Network for Toxoplasmosis, according to both routine and specific clinical situations. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Dengue disease status in Chennai (2006-2008): a retrospective analysis.
Gunasekaran, P; Kaveri, K; Mohana, S; Arunagiri, Kavita; Babu, B V Suresh; Priya, P Padma; Kiruba, R; Kumar, V Senthil; Sheriff, A Khaleefathullah
2011-03-01
Dengue is one of the most important Arboviral diseases in man with outbreaks in Southeast Asia and India. We report a retrospective analysis of the dengue positivity in the referred samples for three years period (2006 to 2008) at the Department of Virology, King Institute of Preventive Medicine, Chennai, Tamil Nadu, India. Serum samples from 1593 suspected cases (968 male and 625 female) were obtained. Of the 1593 cases screened, 1204 (75.5%) were paediatric cases and 389 (24.4%) adults. The samples were subjected to MAC ELISA and IgG ELISA. Of the 968 patients, 686 (43.0%) were positive, of which 579 (84.0%) were in the paediatric age group (<14 yr) and 107 (15.5%) were adults. The IgM positivity being 356 (36.7%) in males and 330 (52.8%) in females. Of the 686 positives, 113 (16.47%) were positive for both IgM and IgG denoting secondary infection. There was a noticeable increased occurrence during the cooler months and during the monsoon and post-monsoon months. The dengue IgM seropositivity among the suspected cases indicates active dengue virus activity. Increase in the probable secondary infections especially in a country like ours where multiple serotypes are prevalent raises concern over probable increase in the incidence of the more serious DHF/DSS. Studies need to be done to identify circulating serotypes of dengue virus to design preventive strategies.
Multi-GNSS Opportunities and Challenges
NASA Astrophysics Data System (ADS)
Al-Shaery, A.; Zhang, S.; Lim, S.; Rizos, C.
2012-04-01
The multi-GNSS era has began attracting more attention with the declaration of full operational capability of GLONASS , with a 24 satellites being set to 'healthy' on December 8th 2011 (IAC, 2011). This means that GPS is no longer the only GNSS that provides global positioning coverage. This status brings benefits for GNSS users in areas (e.g. 'urban canyon' environments or in deep open cut mines) where the number of visible satellites is limited because of shadowing effects. In such areas adding more functioning satellites, which is one of the aiding solutions, becomes easier, at no extra cost. The inclusion of GLONASS observations in positioning solutions will increase the available number of satellites and thus positioning accuracy may improve as a result of enhanced overall satellite geometry. Such an aiding solution is increasingly attractive due to the successful revitalisation of GLONASS. Another motivation is the availability of improved GLONASS orbits from the IGS and individual analysis centres of the IGS. The increasing availability of receivers with GPS/GLONASS tracking capability on the market is an additional motive. Consequently, most networks of continuously operating reference stations (CORS) are now equipped with receivers that can track both GPS and GLONASS satellite signals, and therefore network-based positioning with combined GPS and GLONASS observations is possible. However, adding GLONASS observations to GPS is not a straight forward process. This is attributable to a few system differences in reference frames for time and coordinates, and in signal structures. The first two differences are easy to deal with using well-defined conversion and transformation parameters (El-Mowafy, 2001). However, signal structure differences have some implications. The mathematical modelling of combined GPS/GLONASS observations is not performed as in the case of GPS-alone. Special care should be paid to such integration. Not only is the software part affected but also the hardware. Recent research has identified one of the challenges users may face if precise positioning is sought (Takac, 2009, Yamada et al., 2010, Wanninger, 2011). A user of heterogeneous receiver pairs will experience ambiguity fixing challenges due to inter-channel bias which cannot be cancelled by differencing GLONASS observations, pseudorange or carrier-phase. This paper outlines the opportunities and challenges of combining two currently fully operational GNSS systems (GPS and GLONASS) for precise positioning solutions. Discussion and analysis considering mathematical modelling challenges and users' selection of hardware constraints will be performed.
Utilizing a Rapid Prototyping Approach in the Building of a Hypermedia-Based Reference Station.
ERIC Educational Resources Information Center
Sell, Dan
This paper discusses the building of a hypermedia-based reference station at the Wright Laboratory Technical Library, Wright-Patterson Air Force Base, Ohio. Following this, the paper focuses on an electronic user survey from which data is collected and analysis is made. The survey data is used in a rapid prototyping approach, which is defined as…
Elahian Firouz, Zahra; Kaboosi, Hami; Faghih Nasiri, Abdolreza; Tabatabaie, Seyed Saleh; Golhasani-Keshtan, Farideh; Zaboli, Fatemeh
2014-04-01
Toxoplasmosis is the most common disease in humans and animals (zoonosis) caused by the protozoan parasite Toxoplasma gondii. The disease is usually appeared as asymptomatic in immunocompromised individuals but its most common symptom is lymphadenopathy. Shortly before or during the first trimester of pregnancy, this disease can be transferred to the fetus and cause serious infection in the fetus. In late pregnancy (third trimester), the complications of this infection is very low or unsigned. Due to the absence of non-specific clinical symptoms or slight infection in pregnant women, prenatal diagnosis is often impossible. Since no research compared these two methods, we decided to compare these methods and determine which method works better for diagnosis of toxoplasmosis. In this study, 50 pregnant women who referred to the Chalus Health Center laboratory were included and the blood samples were tested for presence of IgG and IgM antibodies of Toxoplasma gondii by both ELISA and Chemiluminescence methods. Of the 50 samples tested by the ELISA method, 26 samples (52%) were positive for IgG . No samples were positive for IgM. Of the 50 samples tested by the Chemiluminescence method, 28 samples (56%) were positive for IgG. No samples were positive for IgM. A significant relationship between the age of the youngest child and the infection rate was seen. No significant correlation between age, number of individuals in the household, number of children, location, type of construction, consumption of greens, the way of greens and meat consumption, drug use, history of stillbirth and infection levels was seen.
Duty, J Andrew; Szodoray, Peter; Zheng, Nai-Ying; Koelsch, Kristi A; Zhang, Qingzhao; Swiatkowski, Mike; Mathias, Melissa; Garman, Lori; Helms, Christina; Nakken, Britt; Smith, Kenneth; Farris, A Darise; Wilson, Patrick C
2009-01-16
Self-reactive B cells not controlled by receptor editing or clonal deletion may become anergic. We report that fully mature human B cells negative for surface IgM and retaining only IgD are autoreactive and functionally attenuated (referred to as naive IgD(+)IgM(-) B cells [B(ND)]). These B(ND) cells typically make up 2.5% of B cells in the peripheral blood, have antibody variable region genes in germline (unmutated) configuration, and, by all current measures, are fully mature. Analysis of 95 recombinant antibodies expressed from the variable genes of single B(ND) cells demonstrated that they are predominantly autoreactive, binding to HEp-2 cell antigens and DNA. Upon B cell receptor cross-linkage, B(ND) cells have a reduced capacity to mobilize intracellular calcium or phosphorylate tyrosines, demonstrating that they are anergic. However, intense stimulation causes B(ND) cells to fully respond, suggesting that these cells could be the precursors of autoantibody secreting plasma cells in autoimmune diseases such as systemic lupus erythematosus or rheumatoid arthritis. This is the first identification of a distinct mature human B cell subset that is naturally autoreactive and controlled by the tolerizing mechanism of functional anergy.
Kvehaugen, Anne Stine; Aasbrenn, Martin; Farup, Per G
2017-01-01
Baker's/brewer's yeast, Saccharomyces cerevisiae , has been used as an alternative to antibiotic growth promoters to improve growth performance in animals. In humans, Saccharomyces cerevisiae is among the most commonly detected fungi in fecal samples and likely originates from food. Recently, an association between anti- Saccharomyces cerevisiae antibodies (ASCA) and obesity in humans was suggested, but the cause of the elevated ASCA levels is not clear. Our aim was to study ASCA in morbidly obese subjects and explore potential associations with anthropometrics, diet, co-morbidities and biomarkers of inflammation and gut permeability. Subjects with morbid obesity referred to a specialized hospital unit were included. Diet and clinical data were recorded with self-administered questionnaires. Main dietary sources of baker's/brewer's yeast (e.g. bread and beer) were used as a proxy for the intake of yeast. Laboratory analyses included ASCA, serum zonulin (reflecting gut permeability), C-reactive protein and a routine haematological and biochemical screening. One-hundred-and-forty subjects; 109 (78%) female, 98 with dietary records, mean age 43 years and BMI 42 kg/m 2 were included. The number of ASCA positive subjects was 31 (22%) for IgG, 4 (2.9%) for IgA and 3 (2.1%) for IgM. Age, body fat mass and C-reactive protein were significantly higher in IgG-positive compared to IgG-negative subjects ( P < 0.05). A borderline significant association was found between elevated zonulin and ASCA IgG-positivity ( P = 0.06). No association was found between yeast-containing food and ASCA IgG-positivity, or between yeast-containing food and fat mass. The findings indicate that ASCA IgG-positivity may be linked to the generalized inflammation commonly seen with increased adiposity, but not to dietary yeast intake. Other potential causes for the raised ASCA IgG concentrations, such as genetic predisposition, deviations in the gut microbiota and cross-reactivity of ASCA with other antigens, were not explored.
Maudry, Arnaud; Chene, Gautier; Chatelain, Rémi; Patural, Hugues; Bellete, Bahrie; Tisseur, Bernard; Hafid, Jamal; Raberin, Hélène; Beretta, Sophie; Sung, Roger Tran Manh; Belot, Georges; Flori, Pierre
2009-09-01
A comparative study of the Toxoplasma IgG(I) and IgG(II) Access (Access I and II, respectively; Beckman Coulter Inc.), AxSYM Toxo IgG (AxSYM; Abbott Diagnostics), Vidas Toxo IgG (Vidas; bioMerieux, Marcy l'Etoile, France), Immulite Toxo IgG (Immulite; Siemens Healthcare Diagnostics Inc.), and Modular Toxo IgG (Modular; Roche Diagnostics, Basel, Switzerland) tests was done with 406 consecutive serum samples. The Toxo II IgG Western blot (LDBio, Lyon, France) was used as a reference technique in the case of intertechnique discordance. Of the 406 serum samples tested, the results for 35 were discordant by the different techniques. Using the 175 serum samples with positive results, we evaluated the standardization of the titrations obtained (in IU/ml); the medians (second quartiles) obtained were 9.1 IU/ml for the AxSYM test, 21 IU/ml for the Access I test, 25.7 IU/ml for the Access II test, 32 IU/ml for the Vidas test, 34.6 IU/ml for the Immulite test, and 248 IU/ml for the Modular test. For all the immunoassays tested, the following relative sensitivity and specificity values were found: 89.7 to 100% for the Access II test, 89.7 to 99.6% for the Immulite test, 90.2 to 99.6% for the AxSYM test, 91.4 to 99.6% for the Vidas test, 94.8 to 99.6% for the Access I test, and 98.3 to 98.7% for the Modular test. Among the 406 serum samples, we did not find any false-positive values by two different tests for the same serum sample. Except for the Modular test, which prioritized sensitivity, it appears that the positive cutoff values suggested by the pharmaceutical companies are very high (either for economical or for safety reasons). This led to imperfect sensitivity, a large number of unnecessary serological follow-ups of pregnant women, and difficulty in determining the serological status of immunosuppressed individuals.
NASA Astrophysics Data System (ADS)
Husson, V. S.; Long, J. L.; Pearlman, M.
2001-12-01
By the end of 2000, 94% of ILRS stations had completed station and site information forms (i.e. site logs). These forms contain six types of information. These six categories include site identifiers, contact information, approximate coordinates, system configuration history, system ranging capabilities, and local survey ties. The ILRS Central Bureau, in conjunction with the ILRS Networks and Engineering Working Group, has developed procedures to quality control site log contents. Part of this verification entails data integrity checks of local site ties and is the primary focus of this paper. Local survey ties are critical to the combination of space geodetic network coordinate solutions (i.e. GPS, SLR, VLBI, DORIS) of the International Terrestrial Reference Frame (ITRF). Approximately 90% of active SLR sites are collocated with at least one other space geodetic technique. The process used to verify these SLR ties, at collocated sites, is identical to the approach used in ITRF2000. Local vectors (X, Y, Z) from each ILRS site log are differenced from its corresponding ITRF2000 position vectors (i.e. no transformations). These X, Y, and Z deltas are converted into North, East, and Up. Any deltas, in any component, larger than 5 millimeter is flagged for investigation. In the absence of ITRF2000 SLR positions, CSR positions were used. To further enhance this comparison and to fill gaps in information, local ties contained in site logs from the other space geodetic services (i.e. IGS, IVS, IDS) were used in addition to ITRF2000 ties. Case studies of two collocated sites (McDonald/Ft. Davis and Hartebeeshtoek) will be explored in-depth. Recommendations on how local site surveys should be conducted and how this information should be managed will also be presented.
Development and testing of a new ray-tracing approach to GNSS carrier-phase multipath modelling
NASA Astrophysics Data System (ADS)
Lau, Lawrence; Cross, Paul
2007-11-01
Multipath is one of the most important error sources in Global Navigation Satellite System (GNSS) carrier-phase-based precise relative positioning. Its theoretical maximum is a quarter of the carrier wavelength (about 4.8 cm for the Global Positioning System (GPS) L1 carrier) and, although it rarely reaches this size, it must clearly be mitigated if millimetre-accuracy positioning is to be achieved. In most static applications, this may be accomplished by averaging over a sufficiently long period of observation, but in kinematic applications, a modelling approach must be used. This paper is concerned with one such approach: the use of ray-tracing to reconstruct the error and therefore remove it. In order to apply such an approach, it is necessary to have a detailed understanding of the signal transmitted from the satellite, the reflection process, the antenna characteristics and the way that the reflected and direct signal are processed within the receiver. This paper reviews all of these and introduces a formal ray-tracing method for multipath estimation based on precise knowledge of the satellite reflector antenna geometry and of the reflector material and antenna characteristics. It is validated experimentally using GPS signals reflected from metal, water and a brick building, and is shown to be able to model most of the main multipath characteristics. The method will have important practical applications for correcting for multipath in well-constrained environments (such as at base stations for local area GPS networks, at International GNSS Service (IGS) reference stations, and on spacecraft), and it can be used to simulate realistic multipath errors for various performance analyses in high-precision positioning.
Determination of regional Euler pole parameters for Eastern Austria
NASA Astrophysics Data System (ADS)
Umnig, Elke; Weber, Robert; Schartner, Matthias; Brueckl, Ewald
2017-04-01
The horizontal motion of lithospheric plates can be described as rotations around a rotation axes through the Earth's center. The two possible points where this axes intersects the surface of the Earth are called Euler poles. The rotation is expressed by the Euler parameters in terms of angular velocities together with the latitude and longitude of the Euler pole. Euler parameters were calculated from GPS data for a study area in Eastern Austria. The observation network is located along the Mur-Mürz Valley and the Vienna Basin. This zone is part of the Vienna Transfer Fault, which is the major fault system between the Eastern Alps and the Carpathians. The project ALPAACT (seismological and geodetic monitoring of ALpine-PAnnonian ACtive Tectonics) investigated intra plate tectonic movements within the Austrian part in order to estimate the seismic hazard. Precise site coordinate time series established from processing 5 years of GPS observations are available for the regional network spanning the years from 2010.0 to 2015.0. Station velocities with respect to the global reference frame ITRF2008 have been computed for 23 sites. The common Euler vector was estimated on base of a subset of reliable site velocities, for stations directly located within the area of interest. In a further step a geokinematic interpretation shall be carried out. Therefore site motions with respect to the Eurasian Plate are requested. To obtain this motion field different variants are conceivable. In a simple approach the mean ITRF2008 velocity of IGS site GRAZ can be adopted as Eurasian rotational velocity. An improved alternative is to calculate site-specific velocity differences between the Euler rotation and the individual site velocities. In this poster presentation the Euler parameters, the residual motion field as well as first geokinematic interpretation results are presented.
Validation of Antibody-Based Strategies for Diagnosis of Pediatric Celiac Disease Without Biopsy.
Wolf, Johannes; Petroff, David; Richter, Thomas; Auth, Marcus K H; Uhlig, Holm H; Laass, Martin W; Lauenstein, Peter; Krahl, Andreas; Händel, Norman; de Laffolie, Jan; Hauer, Almuthe C; Kehler, Thomas; Flemming, Gunter; Schmidt, Frank; Rodrigues, Astor; Hasenclever, Dirk; Mothes, Thomas
2017-08-01
A diagnosis of celiac disease is made based on clinical, genetic, serologic, and duodenal morphology features. Recent pediatric guidelines, based largely on retrospective data, propose omitting biopsy analysis for patients with concentrations of IgA against tissue transglutaminase (IgA-TTG) >10-fold the upper limit of normal (ULN) and if further criteria are met. A retrospective study concluded that measurements of IgA-TTG and total IgA, or IgA-TTG and IgG against deamidated gliadin (IgG-DGL) could identify patients with and without celiac disease. Patients were assigned to categories of no celiac disease, celiac disease, or biopsy required, based entirely on antibody assays. We aimed to validate the positive and negative predictive values (PPV and NPV) of these diagnostic procedures. We performed a prospective study of 898 children undergoing duodenal biopsy analysis to confirm or rule out celiac disease at 13 centers in Europe. We compared findings from serologic analysis with findings from biopsy analyses, follow-up data, and diagnoses made by the pediatric gastroenterologists (celiac disease, no celiac disease, or no final diagnosis). Assays to measure IgA-TTG, IgG-DGL, and endomysium antibodies were performed by blinded researchers, and tissue sections were analyzed by local and blinded reference pathologists. We validated 2 procedures for diagnosis: total-IgA and IgA-TTG (the TTG-IgA procedure), as well as IgG-DGL with IgA-TTG (TTG-DGL procedure). Patients were assigned to categories of no celiac disease if all assays found antibody concentrations <1-fold the ULN, or celiac disease if at least 1 assay measured antibody concentrations >10-fold the ULN. All other cases were considered to require biopsy analysis. ULN values were calculated using the cutoff levels suggested by the test kit manufacturers. HLA typing was performed for 449 participants. We used models that considered how specificity values change with prevalence to extrapolate the PPV and NPV to populations with lower prevalence of celiac disease. Of the participants, 592 were found to have celiac disease, 345 were found not to have celiac disease, and 24 had no final diagnosis. The TTG-IgA procedure identified patients with celiac disease with a PPV of 0.988 and an NPV of 0.934; the TTG-DGL procedure identified patients with celiac disease with a PPV of 0.988 and an NPV of 0.958. Based on our extrapolation model, we estimated that the PPV and NPV would remain >0.95 even at a disease prevalence as low as 4%. Tests for endomysium antibodies and HLA type did not increase the PPV of samples with levels of IgA-TTG ≥10-fold the ULN. Notably, 4.2% of pathologists disagreed in their analyses of duodenal morphology-a rate comparable to the error rate for serologic assays. In a prospective study, we validated the TTG-IgA procedure and the TTG-DGL procedure in identification of pediatric patients with or without celiac disease, without biopsy. German Clinical Trials Registry no.: DRKS00003854. Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.
PTTI Capabilities of the Modernized LORAN System
2008-12-01
Cape Elizabeth LCCS Carolina Beach 9960-Y Dana 9960-Z Seneca 9960-M LSU 9960-T Sandy Hook Plumbrook Dunbar Forest LCCS Transmitting Station ...reference clocks at the individual transmitting stations , the intra-chain timing between stations , and the overall system synchronization to UTC. Each... station has three cesium clocks installed, and new Time and Frequency Equipment (TFE) was installed at the stations , beginning in the spring of 2003
Weather Extremes Around the World
1974-04-01
the lowest temperature has been recorded at Ust’Shchiigor in the Soviet Union at about 55°N, 50°E.4S This station, located near the Siberian border... Siberian taiga (northern coniferous forest). It is an area of extreme eontinentality, lying near the eastern end of the world’s largest landmass and...HO hours per year Mouse I’ciik Lighthouse, Mistake Island. Maine l"\\ig is a cloud al the surface of Ihe earth, eonsislinj» of a nti’ltilude of
Assessment of different methods to estimate bovine colostrum quality on farm.
Bartens, M-C; Drillich, M; Rychli, K; Iwersen, M; Arnholdt, T; Meyer, L; Klein-Jöbstl, D
2016-09-01
To evaluate two different hydrometers and an optical and a digital Brix refractometer for the assessment of bovine colostrum quality, in terms of accuracy and precision compared with the measurement of IgG concentrations using radial immunodiffusion (RID), and to evaluate the reliability and repeatability of the Brix refractometers. To determine reliability and repeatability, 145 colostrum samples were tested by two independent observers twice, using the optical and digital Brix refractometers. A further 193 colostrum samples from Holstein cows were collected on one commercial dairy farm at first milking and tested with two hydrometers and an optical and digital Brix refractometer. An aliquot of each sample was frozen for RID measurement of IgG concentrations and samples were classified as poor (≤50 g IgG/L) or good (>50 g IgG/L) quality colostrum. Intraclass correlation coefficients (ICC) were used to determine inter- and intra-observer reliability and repeatability. Optimised cut-off values for the four devices were determined using receiver operating characteristics (ROC) analysis with the RID results as the reference. Using these cut-offs, sensitivities and specificities for determining good quality colostrum were calculated. The ICC for inter-observer reliability was 0.98 for the optical Brix refractometer, and for intra-observer repeatability was 0.97 and 0.98 for the optical and the digital Brix refractometers, respectively. For the 193 colostrum samples, 67 (34.7%) had concentrations of IgG ≤50 g/L determined by RID. Optimised cut-off values evaluated by ROC analysis were higher for all devices compared with manufacturer reference or previously published values. Using these values, the sensitivities for the two hydrometers, and the optical and the digital Brix refractometers were 0.73, 0.71, 0.56 and 0.79, respectively; specificities were 0.72, 0.61, 0.90 and 0.69, respectively. The Brix refractometers provided the most accurate assessment of colostrum quality of the devices evaluated, and demonstrated excellent precision in terms of repeatability. To provide optimal health for newborn calves, a sufficient intake of good quality colostrum is essential. The Brix refractometers provide rapid, convenient tools for classification of colostrum quality.
Precise orbit determination of Multi-GNSS constellation including GPS GLONASS BDS and GALIEO
NASA Astrophysics Data System (ADS)
Dai, Xiaolei
2014-05-01
In addition to the existing American global positioning system (GPS) and the Russian global navigation satellite system (GLONASS), the new generation of GNSS is emerging and developing, such as the Chinese BeiDou satellite navigation system (BDS) and the European GALILEO system. Multi-constellation is expected to contribute to more accurate and reliable positioning and navigation service. However, the application of multi-constellation challenges the traditional precise orbit determination (POD) strategy that was designed usually for single constellation. In this contribution, we exploit a more rigorous multi-constellation POD strategy for the ongoing IGS multi-GNSS experiment (MGEX) where the common parameters are identical for each system, and the frequency- and system-specified parameters are employed to account for the inter-frequency and inter-system biases. Since the authorized BDS attitude model is not yet released, different BDS attitude model are implemented and their impact on orbit accuracy are studied. The proposed POD strategy was implemented in the PANDA (Position and Navigation Data Analyst) software and can process observations from GPS, GLONASS, BDS and GALILEO together. The strategy is evaluated with the multi-constellation observations from about 90 MGEX stations and BDS observations from the BeiDou experimental tracking network (BETN) of Wuhan University (WHU). Of all the MGEX stations, 28 stations record BDS observation, and about 80 stations record GALILEO observations. All these data were processed together in our software, resulting in the multi-constellation POD solutions. We assessed the orbit accuracy for GPS and GLONASS by comparing our solutions with the IGS final orbit, and for BDS and GALILEO by overlapping our daily orbit solution. The stability of inter-frequency bias of GLONASS and inter-system biases w.r.t. GPS for GLONASS, BDS and GALILEO were investigated. At last, we carried out precise point positioning (PPP) using the multi-constellation POD orbit and clock products, and analyzed the contribution of these POD products to PPP. Keywords: Multi-GNSS, Precise Orbit Determination, Inter-frequency bias, Inter-system bias, Precise Point Positioning
NASA Astrophysics Data System (ADS)
Klos, Anna; Pottiaux, Eric; Van Malderen, Roeland; Bock, Olivier; Bogusz, Janusz
2017-04-01
A synthetic benchmark dataset of Integrated Water Vapour (IWV) was created within the activity of "Data homogenisation" of sub-working group WG3 of COST ES1206 Action. The benchmark dataset was created basing on the analysis of IWV differences retrieved by Global Positioning System (GPS) International GNSS Service (IGS) stations using European Centre for Medium-Range Weather Forecats (ECMWF) reanalysis data (ERA-Interim). Having analysed a set of 120 series of IWV differences (ERAI-GPS) derived for IGS stations, we delivered parameters of a number of gaps and breaks for every certain station. Moreover, we estimated values of trends, significant seasonalities and character of residuals when deterministic model was removed. We tested five different noise models and found that a combination of white and autoregressive processes of first order describes the stochastic part with a good accuracy. Basing on this analysis, we performed Monte Carlo simulations of 25 years long data with two different types of noise: white as well as combination of white and autoregressive processes. We also added few strictly defined offsets, creating three variants of synthetic dataset: easy, less-complicated and fully-complicated. The 'Easy' dataset included seasonal signals (annual, semi-annual, 3 and 4 months if present for a particular station), offsets and white noise. The 'Less-complicated' dataset included above-mentioned, as well as the combination of white and first order autoregressive processes (AR(1)+WH). The 'Fully-complicated' dataset included, beyond above, a trend and gaps. In this research, we show the impact of manual homogenisation on the estimates of trend and its error. We also cross-compare the results for three above-mentioned datasets, as the synthetized noise type might have a significant influence on manual homogenisation. Therefore, it might mostly affect the values of trend and their uncertainties when inappropriately handled. In a future, the synthetic dataset we present is going to be used as a benchmark to test various statistical tools in terms of homogenisation task.
Three decades of harnessing the GPS data explosion for geophysics (Vening Meinesz Medal Lecture)
NASA Astrophysics Data System (ADS)
Blewitt, Geoffrey
2015-04-01
In this presentation, I attempt to convey the immensity of the task that faced the geodesy community three decades ago, and continues to challenge us, to harness all potentially valuable GPS data available in the world for geophysical science. It would be fair to see that three decades ago, we were struggling with controlled tests just to get GPS geodesy working, and had little time to imagine the flood of data today. Yet the geodesy community has succeeded in meeting this challenge. Today, for example, the Nevada Geodetic Laboratory produces and makes publicly available coordinate time series for over 12,000 geodetic GPS station around the globe with various data intervals, latencies, and reference frames. About 8,000 stations have their daily time series updated every week, with 4,000 being updated the next day with coordinates at daily and 5 minute intervals. About 2,000 stations have their time series updated every hour with coordinates at 5 minute intervals. I will show examples of how these time series are being used by NGL and many other scientists to study a wide variety of geophysical topics, including plate tectonics, earthquake modeling, seismic and tsunami hazard, volcanic deformation, water resources, mountain growth, terrestrial reference frame realization, glacial isostatic adjustment, ice sheet melting, sea level rise and coastal subsidence, and even fundamental physics, using GPS atomic clocks to probe the nature of dark matter in the universe. The explosion in GPS data has challenged us to invent new data processing algorithms and develop robust automation in order to keep up with the flood. This explosion has been exponential, and therefore it can be said that it is not a recent phenomena, but rather that it began in the earliest years of GPS geodesy, and has always posed a challenge to us. Over the course of my post-doctoral career starting in late 1985, I have had the good fortune to witness the key developments that have taken place since the early years of geodetic GPS and over the course of three decades. These developments continue today as strongly as ever. Essential innovations have included, for example, automation of GPS cycle slip detection and mitigation, carrier phase ambiguity resolution, the birth and operation of the IGS for reliable orbit and clock estimation, the invention of algorithms that scale linearly with the number of stations, and the deep integration of GPS solutions into the ITRF, providing measures of accuracy, precision, and stability. As a recent example of automation, I show a new non-parametric algorithm to estimate station velocities quickly and robustly, without need to detect and correct for outliers, seasonal signals, and discontinuities in the time series steps that commonly occur due to equipment changes. The complete automation from data collection to production of station velocities (and, now, velocity time series) allows us to process all potentially valuable data, and to focus more on discovery and analysis of the results for geophysical applications, often with great redundancy in the data leading to high statistical significance and more robust scientific conclusions. I show by example that another benefit of this capability to process all data in a robust turn-key fashion is to enhance the opportunity for making discoveries, without necessarily planning all of the steps that can lead us to discovery's door.
Silva-Del-Río, N; Rolle, D; García-Muñoz, A; Rodríguez-Jiménez, S; Valldecabres, A; Lago, A; Pandey, P
2017-07-01
The objective of this study was to evaluate colostrum IgG concentration harvested at first and second milking from multiparous Jersey cows, the dam's lactation number, colostrum yield, and time of first milking. In addition, we validated the use of a Brix refractometer to estimate IgG concentration in colostrum from multiparous Jersey cows using radial immunodiffusion as the reference method. Colostrum samples and total weight of colostrum harvested at first (n = 134) and second (n = 68) milking were collected from 134 multiparous Jersey cows housed in a California herd. Fresh colostrum samples were analyzed for IgG concentration with Brix refractometry and frozen samples by radial immunodiffusion. A total of 90.4 and 42.7% of the samples from first and second milking met industry standards of quality for IgG concentration (>50 g/L). Second and third lactation cows had similar colostrum IgG concentration but lower than cows on their fourth and greater lactation. At second milking, 56.4% of cows on their fourth or greater lactation had colostrum IgG concentrations >50 g/L. When colostrum yield increased from low (<3 kg), medium (3 to 6 kg), to high (>6 kg), IgG concentration decreased. Higher IgG concentration was observed on colostrum harvested at <6 h (short) versus 6 to 11 h (medium) after calving. However, IgG concentration in colostrum harvested after 11 h (long) was similar to that harvested at short and medium time. Readings of %Brix were highly correlated with IgG at first (r = 0.81) and second (r = 0.77) milking. The best Brix threshold to identify colostrum from first milking with >50 IgG g/L was 20.9% based on logit equations with Youden's index criterion and 18.0% based on accuracy criterion. For colostrum harvested at second milking, similar Brix thresholds were obtained, 19.2 and 19.0%, regardless of whether Youden's index or accuracy was used as the selection criterion. Our results indicate that the dam's lactation number, colostrum yield, and time of first milking relative to calving are associated with IgG concentration in colostrum from multiparous Jersey cows. Second milking colostrum from mature Jersey cows should be evaluated to extend colostrum supply on dairies especially during times of shortage. Readings of %Brix can be used to rapidly estimate IgG concentration in Jersey colostrum harvested at first and second milking. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
St Fleur, S.; Courboulex, F.; Bertrand, E.; Deschamps, A.; Mercier de Lepinay, B.; Prepetit, C.; Hough, S. E.
2013-12-01
Haiti was struck in January 2010 by a strong Mw=7 earthquake that caused extensive damages in the city of Port au Prince. At this time, very few seismological stations were working in Haiti and the only one that recorded the mainshock in Port au Prince was saturated. Thus, there were no direct measurements of the ground motion produced by this large event. Quickly after the 2010 event, several permanent accelerometric stations were installed by the USGS (U.S. Geological Survey) and the BME (Bureau des Mines et de l'Energie d'Haiti) as well as broad-band stations by the GSC (Geological Survey of Canada). Since their installation, these stations recorded several tens of aftershocks. The aim of our work is to take advantage of this new dataset to better understand the ground motions generated by earthquakes in the city of Port au Prince. We have used first spectral ratio methods to obtain the transfer function of each station, and then an empirical Green's Function simulation approach to combine source and site effects. In order to estimate site effects under each station, we have used classical spectral ratio methods. In a first step, the H/V (Horizontal/Vertical) method was used to select a reference station (in Port au Prince) that should be ideally a station without any site effects. We selected two stations, HCEA and PAPH, as reference stations, as even if the shape of their H/V curves is not always equal to 1 in the entire frequency band. In a second step, we computed the transfer function at each station by a ratio between the spectra of each earthquake at each station and the spectra obtained at the reference station (we use successively HCEA, PAPH and a combination of both). The results were kept only for the frequencies where the signal to noise was larger than 3. In the frequency range 1 to 20 Hz, we found site/reference ratios that reach values from 3 to 8 and a large variability from one station to another one. In the low frequency band 0.5 to 1 Hz a peak is present at almost all the stations in Port au Prince, which may indicate an amplification due to a deep interface. However, these values have a large variability from one earthquake recording to the other. This may indicate that the observed amplification depends not only on the effect of local site, but also on the source or the propagation direction. We then used the recordings of two earthquakes (Mw 4.3 and Mw 4.4) that occurred on the Leogane fault as Empirical Green's Functions (EGF) in order to simulate the ground motions generated by a virtual Mw 6.8 earthquake. For this simulation a stochastic EGF summation method was used. The results obtained using the two events are surprisingly very different. Using the first EGF, nearly the same ground motion was obtained at each station in Port-au-Prince, whereas with the second EGF, the results highlight large differences. Finally, the estimated site response (site/reference) was used in combination with a direct estimation of the rock site motion (HCEA simulation) in order to reproduce the ground motions which were compared to the EGF simulation method. The comparison confirms the large variability in the modeled ground shaking which can be due to both site and source effects and the low frequency amplification on the plain of Port-au-Prince.
47 CFR 1.1704 - Station files.
Code of Federal Regulations, 2010 CFR
2010-10-01
... System (COALS) § 1.1704 Station files. Applications, notifications, correspondence, electronic filings... Television Relay Service (CARS) are maintained by the Commission in COALS and the Public Reference Room...
NASA Astrophysics Data System (ADS)
Retscher, G.
2017-09-01
Positioning of mobile users in indoor environments with Wireless Fidelity (Wi-Fi) has become very popular whereby location fingerprinting and trilateration are the most commonly employed methods. In both the received signal strength (RSS) of the surrounding access points (APs) are scanned and used to estimate the user's position. Within the scope of this study the advantageous qualities of both methods are identified and selected to benefit their combination. By a fusion of these technologies a higher performance for Wi-Fi positioning is achievable. For that purpose, a novel approach based on the well-known Differential GPS (DGPS) principle of operation is developed and applied. This approach for user localization and tracking is termed Differential Wi-Fi (DWi-Fi) by analogy with DGPS. From reference stations deployed in the area of interest differential measurement corrections are derived and applied at the mobile user side. Hence, range or coordinate corrections can be estimated from a network of reference station observations as it is done in common CORS GNSS networks. A low-cost realization with Raspberry Pi units is employed for these reference stations. These units serve at the same time as APs broadcasting Wi-Fi signals as well as reference stations scanning the receivable Wi-Fi signals of the surrounding APs. As the RSS measurements are carried out continuously at the reference stations dynamically changing maps of RSS distributions, so-called radio maps, are derived. Similar as in location fingerprinting this radio maps represent the RSS fingerprints at certain locations. From the areal modelling of the correction parameters in combination with the dynamically updated radio maps the location of the user can be estimated in real-time. The novel approach is presented and its performance demonstrated in this paper.
NASA Astrophysics Data System (ADS)
Guzman, David G.
An electrical substation is composed of various subsystems that allow for the effective and safe operation of the power grid. One of the subsystems integrating a conventional substation is defined as the ground grid system. This system allows for the effective operation of the power grid and all the electrical equipment connected to it by providing a ground potential reference, commonly known as the system ground. In addition, the ground grid system provides safety to the workers and the public transiting inside or living nearby a substation by reducing the step and touch potential (or voltage) levels present during a system fault. In today's utility industry practices there is an increasing trend for using pad-mounted electrical equipment for substation applications in an effort to construct new or upgrade existing electrical facilities inside limited property spaces. This thesis work presents an analysis for the effects of touch and step voltages at existing distribution substations where 23.9kV to 4.16kV & 13.8kV to 4.16kV pad-mounted transformers and other pad-mounted switchgear was installed to replace the traditional station class equipment. Moreover, this study will expose modeling techniques employed to define and determine the effects of floating grounds and other exposed metal bodies inside or surrounding these substations using WinIGS; this is in an effort to determine any risks of electric shock associated with this type of installations. The results presented in this work are intended to verify the requirements for the ground grid analysis and design for 4.16kV distribution substations with pad-mounted equipment in order to prevent dangerous step and touch voltage levels appearing at these sites during system faults; and ultimately prevent exposing individuals to the risk of an electric shock.
NASA Astrophysics Data System (ADS)
Meertens, Charles; Boler, Fran; Miller, M. Meghan
2015-04-01
UNAVCO community investigators are actively engaged in using space and terrestrial geodetic techniques to study earthquake processes, mantle properties, active magmatic systems, plate tectonics, plate boundary zone deformation, intraplate deformation, glacial isostatic adjustment, and hydrologic and atmospheric processes. The first GPS field projects were conducted over thirty years ago, and from the beginning these science investigations and the UNAVCO constituency as a whole have been international and collaborative in scope and participation. Collaborations were driven by the nature of the scientific problems being addressed, the capability of the technology to make precise measurements over global scales, and inherent technical necessity for sharing of GPS tracking data across national boundaries. The International GNSS Service (IGS) was formed twenty years ago as a voluntary federation to share GPS data from now hundreds of locations around the globe to facilitate realization of global reference frames, ties to regional surveys, precise orbits, and to establish and improve best practices in analysis and infrastructure. Recently, however, numbers of regional stations have grown to the tens of thousands, often with data that are difficult to access. UNAVCO has been working to help remove technical barriers by providing open source tools such as the Geodetic Seamless Archive Centers software to facilitate cross-project data sharing and discovery and by developing Dataworks software to manage network data. Data web services also provide the framework for UNAVCO contributions to multi-technique, inter-disciplinary, and integrative activities such as CoopEUS, GEO Supersites, EarthScope, and EarthCube. Within the geodetic community, metadata standards and data exchange formats have been developed and evolved collaboratively through the efforts of global organizations such as the IGS. A new generation of metadata and data exchange formats, as well as the software tools that utilize these formats and that support more efficient exchange of the highest quality data and metadata, are currently being developed and deployed through multiple international efforts.
NASA Astrophysics Data System (ADS)
Jiang, Weiping; Deng, Liansheng; Zhou, Xiaohui; Ma, Yifang
2014-05-01
Higher-order ionospheric (HIO) corrections are proposed to become a standard part for precise GPS data analysis. For this study, we deeply investigate the impacts of the HIO corrections on the coordinate time series by implementing re-processing of the GPS data from Crustal Movement Observation Network of China (CMONOC). Nearly 13 year data are used in our three processing runs: (a) run NO, without HOI corrections, (b) run IG, both second- and third-order corrections are modeled using the International Geomagnetic Reference Field 11 (IGRF11) to model the magnetic field, (c) run ID, the same with IG but dipole magnetic model are applied. Both spectral analysis and noise analysis are adopted to investigate these effects. Results show that for CMONOC stations, HIO corrections are found to have brought an overall improvement. After the corrections are applied, the noise amplitudes decrease, with the white noise amplitudes showing a more remarkable variation. Low-latitude sites are more affected. For different coordinate components, the impacts vary. The results of an analysis of stacked periodograms show that there is a good match between the seasonal amplitudes and the HOI corrections, and the observed variations in the coordinate time series are related to HOI effects. HOI delays partially explain the seasonal amplitudes in the coordinate time series, especially for the U component. The annual amplitudes for all components are decreased for over one-half of the selected CMONOC sites. Additionally, the semi-annual amplitudes for the sites are much more strongly affected by the corrections. However, when diplole model is used, the results are not as optimistic as IGRF model. Analysis of dipole model indicate that HIO delay lead to the increase of noise amplitudes, and that HIO delays with dipole model can generate false periodic signals. When dipole model are used in modeling HIO terms, larger residual and noise are brought in rather than the effective improvements.
High Frequency Variations in Earth Orientation Derived From GNSS Observations
NASA Astrophysics Data System (ADS)
Weber, R.; Englich, S.; Snajdrova, K.; Boehm, J.
2006-12-01
Current observations gained by the space geodetic techniques, especially VLBI, GPS and SLR, allow for the determination of Earth Orientation Parameters (EOPs - polar motion, UT1/LOD, nutation offsets) with unprecedented accuracy and temporal resolution. This presentation focuses on contributions to the EOP recovery provided by satellite navigation systems (primarily GPS). The IGS (International GNSS Service), for example, currently provides daily polar motion with an accuracy of less than 0.1mas and LOD estimates with an accuracy of a few microseconds. To study more rapid variations in polar motion and LOD we established in a first step a high resolution (hourly resolution) ERP-time series from GPS observation data of the IGS network covering the period from begin of 2005 till March 2006. The calculations were carried out by means of the Bernese GPS Software V5.0 considering observations from a subset of 79 fairly stable stations out of the IGb00 reference frame sites. From these ERP time series the amplitudes of the major diurnal and semidiurnal variations caused by ocean tides are estimated. After correcting the series for ocean tides the remaining geodetic observed excitation is compared with variations of atmospheric excitation (AAM). To study the sensitivity of the estimates with respect to the applied mapping function we applied both the widely used NMF (Niell Mapping Function) and the VMF1 (Vienna Mapping Function 1). In addition, based on computations covering two months in 2005, the potential improvement due to the use of additional GLONASS data will be discussed. Finally, satellite techniques are also able to provide nutation offset rates with respect to the most recent nutation model. Based on GPS observations from 2005 we established nutation rate time series and subsequently derived the amplitudes of several nutation waves with periods less than 30 days. The results are compared to VLBI estimates processed by means of the OCCAM 6.1 software.
Humoral and cellular immunity in cosmonauts after the ISS missions
NASA Astrophysics Data System (ADS)
Rykova, M. P.; Antropova, E. N.; Larina, I. M.; Morukov, B. V.
Spaceflight effects on the immune system were studied in 30 cosmonauts flown onto the International Space Station (ISS) for long- (125-195 d, n=15) and short-term (8-10 d, n=15) missions. Immunological investigations before launch and after landing were performed by using methods for quantitative and functional evaluation of the immunologically competent cells. Specific assays include: peripheral leukocyte distribution, natural killer (NK) cell cytotoxic activity, phagocytic activity of monocytes and granulocytes, proliferation of T-cells in response to a mitogen, levels of immunoglobulins IgA, IgM, IgG, virus-specific antibody and cytokine in serum. It was noticed that after long-term spaceflights the percentage of NK (CD3-/CD16+/CD56+) cells was significantly reduced compared with pre-flight data (p<0.05) and NK activity was suppressed by 20-85% as compared with pre-flight data in 12 out of 15 cosmonauts. T-lymphocyte activity was decreased by 25-39% as compared with pre-flight data in 5 out of 13 cosmonauts. However, the relative number of CD3+, CD4+ and CD8+ T-cells did not change. The functional activity of NK and T-cells decreased in some of the cosmonauts after short-term missions. On the other hand, a moderate trend upward of NK cytotoxic activity and proliferative activity of T-cells was observed in some individuals. Concentrations immunoglobulins (IgA, IgM, IgG) and levels of M and G antibodies to herpes simplex virus (HSV), cytomegalovirus (CMV), Epstein-Barr virus (EBV) and herpes virus type 6 (HV6) in serum did not reveal significant changes after long- and short-term flights. Concentrations of cytokines (IL- 1β, IL-2, IL-4 and TNF- α) in serum changed in an apparently random manner as compared with values before long- and short-term missions. Despite the fact that many improvements have been made to the living conditions of aboard the ISS our investigations demonstrate the remarkable depression of the immunological function after the ISS missions. These results suggest that the clinical health risk (related to immune dysfunction) will occur during exploration class missions.
On the establishment and maintenance of a modern conventional terrestrial reference system
NASA Technical Reports Server (NTRS)
Bock, Y.; Zhu, S. Y.
1982-01-01
The frame of the Conventional Terrestrial Reference System (CTS) is defined by an adopted set of coordinates, at a fundamental epoxh, of a global network of stations which contribute the vertices of a fundamental polyhedron. A method to estimate this set of coordinates using a combination of modern three dimensional geodetic systems is presented. Once established, the function of the CTS is twofold. The first is to monitor the external (or global) motions of the polyhedron with respect to the frame of a Conventional Inertial Reference System, i.e., those motions common to all stations. The second is to monitor the internal motions (or deformations) of the polyhedron, i.e., those motions that are not common to all stations. Two possible estimators for use in earth deformation analysis are given and their statistical and physical properties are described.
NASA Astrophysics Data System (ADS)
Liwosz, T.; Ryczywolski, M.
2016-12-01
The new solution for the Polish geodetic primary GNSS network was created to verify the currently used reference frame (PL-ETRF2000). The new solution is based on more GNSS data (more daily observation sessions included, a longer data timespan, GLONASS observations added) which were processed in a newer reference frame (IGb08) according to up-to-date methodology and using the latest version of Bernese GNSS Software. The new long-term solution (spanning 3.7 years) was aligned to the IGb08 reference frame using a minimum constraints approach. We categorized Polish reference stations into two categories according to their data length. We obtained good agreement of the new solution with the PL-ETRF2000: for most stations position differences did not exceed 5 mm in horizontal, and 10 mm in vertical components. However, for 30 stations we observed discontinuities in position time series, mostly due to GNSS equipment changes, which occured after the introduction of PL-ETRF2000. Position changes due to the discontinuities reached 9.1 mm in horizontal components, and 26.9 mm in vertical components. The new solution takes into account position discontinuities, and in addition also includes six new stations which were installed after the introduction of the PL-ETRF2000. Therefore, we propose to update the currently-used reference frame for the Polish geodetic primary network (PL-ETRF2000) with the new solution. The new solution was also accepted by the EUREF Technical Working Group as a class A solution (highest accuracy) according to EUREF standards.
Villarreal-Pérez, Jesús Zacarías; Ramírez-Aranda, José Manuel; Rodríguez-Rodríguez, Irasema; Perales-Dávila, José; García-Elizondo, Francisco Javier; Gómez-Gómez, Celina; Galindo-Galindo, Edgar; Rodríguez-Moreno, Marco Antonio; Ballesteros-Elizondo, Romelia
2014-09-01
To assess placental transfer of antibodies to the child at birth and at 2 months of age. For the quantification of anti-PT IgG antibodies, we used an indirect enzyme-linked immunosorbent assay standardized by The National Institute of Epidemiologic Diagnosis and Reference (InDRE). Samples were considered negative from 0 to 48 IU/mL, indeterminate from 49 to 93 IU/mL and positive at ≥94 IU/mL. We performed a cross-sectional assessment of anti-PT IgG antibody levels in the mother, umbilical cord, and child. There was a higher concentration of IgG anti-TP in the umbilical cord (4.3%) and in the mother (1.4%), but a total absence was observed in the child (0%). The vulnerability of children to Bordetella pertussis shows the need to implement effective immunization strategies, whether actively, in the child, or passively through the mother, adolescents, and adults who are in contact with the child.
SpermCheck: a simplified screening assay for immunological infertility.
McClure, R D; Tom, R A; Watkins, M; Murthy, S
1989-10-01
SpermCheck (Bio-Rad Laboratories, Hercules, CA), a new screening test for regional surface antibodies on motile sperm, uses monodispersed latex microspheres of uniform size as a vehicle to link rabbit antihuman immunoglobulins (IgA, IgG, IgM) and provides both negative and positive control sera, as well as sufficient buffer for sperm preparation in ambient CO2 atmosphere. When compared with reference data available for the immunobead test (IBT), the direct protocol (semen) for SpermCheck yielded 94.4% sensitivity with 100% specificity; the indirect protocol (serum) provided a sensitivity of 100% with 94.7% specificity. The microspheres of SpermCheck maintain a nearly uniform concentration per volume, with none to negligible clumping. The greater difference between the optical densities of latex and cytoplasm allows use of a light microscope for the rapid assessment of the percent of regional binding rather than the phase-contrast microscope required for the IBT. SpermCheck eliminates many difficulties encountered with the IBT, making SpermCheck a convenient screening assay for use in the physician's office.
NASA Astrophysics Data System (ADS)
Dousa, J.; Vaclavovic, P.; Gyori, G.
2012-12-01
Geodetic Observatory Pecný (GOP) has a long-term experience in the estimation of precise tropospheric parameters from GNSS permanent stations, in particular under the limited timelines of near real time. More than a decade, the GOP zenith total delays (ZTD) contributed to various projects in Europe (COST-716, TOUGH, E-GVAP, E-GVAP II) and the operational ZTD hourly updated product flows via the meteorological observation exchange network - GTS - to the end users worldwide. Currently, the GOP regional ZTD product is operationally assimilated in Météo France and UK MetOffice at least and further exploited in various ways at many other meteorological institutions. New developments at GOP over last three years consist of a) implementation and assessment of the global hourly ZTD product of about 170 stations, b) implementation of routine multi-GNSS (GPS+GLONASS) ZTD European product, and c) implementation of ultra-fast/real-time ZTD product. The GOP global ZTD product has been implemented on request of the meteorological institutions running global numerical weather forecasting models. The global ZTD product was seriously evaluated over ten months (Oct 2009 - Aug 2011) when compared to reprocessed EUREF and IGS ZTDs, radiosondes and ZTDs derived from UK MetOffice's global numerical weather model. After the evaluation (and on special request of UK MetOffice) the product has been switched from testing to operational status within the framework of the EUMETNET EIG GPS Water Vapour Programme (E-GVAP) and officially disseminated via the GTS network. The GOP multi-GNSS ZTD solution has been tested since 2009 shortly after developing GOP ultra-rapid GPS+GLONASS orbits for the International GNSS Service (IGS). A specific bias of mean value 1.5 mm was identified between GPS- and GLONASS-only ZTD at that time, and relation to the IGS05 antenna phase centre offset and variation models (PCO+PCV) identified. Consequently, the implementation of a routine operation has been done after the GPS week 1632 together with adopting IGS08 PCO+PCVs, which eliminated the bias and demonstrated an overall general better consistence between GPS- and GLONASS-only ZTD estimates. The multi-GNSS ZTD product runs in parallel to the GPS-only and is going to replace the current official GPS-only product after more than a year assessment. This multi-GNSS product has assesses a satisfactory quality and robustness of unofficial IGS ultra-rapid GPS+GLONASS orbits necessary for multi-GNSS solution. The GOP ultra-fast and real-time ZTD estimation is being developed with in-house software application using own G-Nut library and Precise Point Positioning technique (in contrast to all other GOP ZTD products based on Bernese GPS software and based on double-difference observations). The IGS Real-time Pilot Project orbit and clock corrections are seriously exploited in these ultra-fast and real-time tropospheric products aimed for nowcasting and severe weather monitoring. Our implementation assesses an optimal balance between timelines and product quality required by these applications.
Global daily reference evapotranspiration modeling and evaluation
Senay, G.B.; Verdin, J.P.; Lietzow, R.; Melesse, Assefa M.
2008-01-01
Accurate and reliable evapotranspiration (ET) datasets are crucial in regional water and energy balance studies. Due to the complex instrumentation requirements, actual ET values are generally estimated from reference ET values by adjustment factors using coefficients for water stress and vegetation conditions, commonly referred to as crop coefficients. Until recently, the modeling of reference ET has been solely based on important weather variables collected from weather stations that are generally located in selected agro-climatic locations. Since 2001, the National Oceanic and Atmospheric Administration’s Global Data Assimilation System (GDAS) has been producing six-hourly climate parameter datasets that are used to calculate daily reference ET for the whole globe at 1-degree spatial resolution. The U.S. Geological Survey Center for Earth Resources Observation and Science has been producing daily reference ET (ETo) since 2001, and it has been used on a variety of operational hydrological models for drought and streamflow monitoring all over the world. With the increasing availability of local station-based reference ET estimates, we evaluated the GDAS-based reference ET estimates using data from the California Irrigation Management Information System (CIMIS). Daily CIMIS reference ET estimates from 85 stations were compared with GDAS-based reference ET at different spatial and temporal scales using five-year daily data from 2002 through 2006. Despite the large difference in spatial scale (point vs. ∼100 km grid cell) between the two datasets, the correlations between station-based ET and GDAS-ET were very high, exceeding 0.97 on a daily basis to more than 0.99 on time scales of more than 10 days. Both the temporal and spatial correspondences in trend/pattern and magnitudes between the two datasets were satisfactory, suggesting the reliability of using GDAS parameter-based reference ET for regional water and energy balance studies in many parts of the world. While the study revealed the potential of GDAS ETo for large-scale hydrological applications, site-specific use of GDAS ETo in complex hydro-climatic regions such as coastal areas and rugged terrain may require the application of bias correction and/or disaggregation of the GDAS ETo using downscaling techniques.
Mosser, Mathilde; Kapel, Romain; Chevalot, Isabelle; Olmos, Eric; Marc, Ivan; Marc, Annie; Oriol, Eric
2015-01-01
Yeast extract (YE) is known to greatly enhance mammalian cell culture performances, but its undefined composition decreases process reliability. Accordingly, in the present study, the nature of YE compounds involved in the improvement of recombinant CHO cell growth and IgG production was investigated. First, the benefits of YE were verified, revealing that it increased maximal concentrations of viable cells and IgG up to 73 and 60%, respectively compared to a reference culture. Then, the analyses of YE composition highlighted the presence of molecules such as amino acids, vitamins, salts, nucleobase, and glucose that were contained in reference medium, while others including peptides, trehalose, polysaccharides, and nucleic acids were not. Consequently, YE was fractionated by a nanofiltration process to deeper evaluate its effects on CHO cell cultures. The YE molecules already contained in reference medium were mainly isolated in the permeate fraction together with trehalose and short peptides, while other molecules were concentrated in the retentate. Permeate, which was free of macromolecules, exhibited a similar positive effect than raw YE on maximal concentrations. Additional studies on cell energetic metabolism underlined that dipeptides and tripeptides in permeate were used as an efficient source of nitrogenous substrates. © 2015 American Institute of Chemical Engineers.
Crustal movements in Europe observed with EUROPE and IVS-T2 VLBI networks
NASA Astrophysics Data System (ADS)
Zubko, N.; Poutanen, M.
2011-07-01
The comparative analysis of the EUROPE and IVS-T2 geodetic VLBI sessions has been performed. The main purpose of both campaigns is to observe and accurately determine the VLBI station coordinates and their time evolution. In this analysis our interest is to understand the influence of network configuration on the estimated parameters and, also, how much the results of these two campaigns are consistent. We have used the VieVS software developing at Vienna University of Technology to analyze the EUROPE and IVS-T2 sessions of 2002-2009. We have analyzed the difference of crustal movements obtained with these two networks and the effect of network configuration and station selection. The EPN (EUREF permanent GNSS Network) and IGS (International GNSS Service) networks can be used to compare the results.
Diagnosis of Lyme-associated uveitis: value of serological testing in a tertiary centre.
Bernard, Alexia; Kodjikian, Laurent; Abukhashabh, Amro; Roure-Sobas, Chantal; Boibieux, Andre; Denis, Philippe; Broussolle, Christiane; Seve, Pascal
2018-03-01
To determine the frequency and clinical presentation of Lyme disease in patients with uveitis and to assess the value of Borrelia burgdorferi serological testing. Retrospective study on all patients with uveitis who were referred to our tertiary hospital were serologically tested for Lyme in our laboratory between 2003 and 2016. Screening consisted of determining B. burgdorferi serum IgG and IgM by ELISA method. The patient's serology was considered as positive if the ELISA-positive result in IgM and/or IgG was confirmed by an immunoblot positive in IgM and/or IgG. Lyme-associated uveitis was diagnosed based on serological results as well as response to antibiotics and exclusion of other diagnosis. Of the 430 patients with uveitis (60% women, mean age 49 years) fulfilling inclusion criteria, 63 (14.7%) had an ELISA-positive serology, confirmed by immunoblot for 34 patients (7.9%). The diagnosis of Lyme-associated uveitis was finally retained in seven patients (1.6%). These patients reported either a previous exposure including tick bite or forest walks (n=5), symptoms suggestive of Lyme disease (n=5) and resistance to local and/or systemic steroids (n=7). Among the remaining 27 positive patients, 22 had other established aetiologies and 5 other were unclassified. The seroprevalence of B. burgdorferi among our patients with uveitis was 7.9% compared with 6 to 8.5% in the general French population which leads to a low predictive value of serological testing. Its use should be reserved for patients with unexplained uveitis, an exposure history, systemic findings suggestive of Lyme disease and steroids resistance. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Cow's milk allergic children-Can component-resolved diagnostics predict duration and severity?
Petersen, Thomas Houmann; Mortz, Charlotte Gotthard; Bindslev-Jensen, Carsten; Eller, Esben
2018-03-01
Cow's milk allergy (CMA) affects 2% of all children. This study investigatescomponent-resolved diagnostics(CRD) to cow's milk proteins in children suspected of CMA, by correlating the level of CRD with outcome of the oral challenge. Furthermore, we evaluate the ability of serial CRD measurements to distinguish children with persistent CMA from children developing tolerance. We included data from 78 children referred to the Allergy Centre during a 13-year period. Results from oral food challenges including threshold, severity, and sensitization data (IgE antibodies to whole milk protein, IgE components toward milk and skin prick test (SPT)) were collected. The milk allergic children were re-evaluated with sensitization data and rechallenges regularly. Thirty-nine children had negative first challenges, and 39 had positive first challenges. The positive group was rechallenged and separated into 3 groups depending on time to remission. At inclusion, children with persistent CMA had significantly larger size of SPT and higher levels of s-IgE to milk and CRD compared to the other groups. SPT wheal size was significantly larger in children with persistent CMA compared to children outgrowing CMA. Furthermore, a correlation between s-IgE level to cow's milk and casein and the severity of the allergic reaction elicited by food challenges was found. Oral food challenge cannot be replaced by s-IgE to whole milk protein or milk components nor SPT in the diagnosis of CMA; however, high levels of milk components and s-IgE to milk increase the risk of a long-lasting or persisting CMA. © 2018 EAACI and John Wiley and Sons A/S. Published by John Wiley and Sons Ltd.
Hernandez, D; Nydam, D V; Godden, S M; Bristol, L S; Kryzer, A; Ranum, J; Schaefer, D
2016-05-01
A series of trials were conducted to evaluate Brix refractometry (Brix %) for the assessment of failure of passive transfer (FPT) in dairy calves compared to: (1) serum IgG (reference standard) when measured by radial immunodiffusion (RID) or a turbidometric immunoassay (TIA), and (2) serum total protein refractometry (STP). For the serum samples tested with TIA, STP, and Brix % (n = 310; Holstein calves), the median concentrations were 21.3 g/L IgG, 58 g/L STP, and 9.2%, respectively. For the serum samples tested with RID, STP and Brix % (n = 112; Jersey calves), the mean concentrations were 38 g/L IgG, 68 g/L STP, and 10.2%, respectively. For samples tested with only Brix % and STP (n = 265; Holstein calves), median STP and Brix % were 50 g/L STP and 8.5%, respectively. Correlations between Brix % and RID, and between Brix % and TIA were equal (r = 0.79, respectively). Brix % and STP were positively correlated (r = 0.99). Brix % estimated serum IgG concentrations determined by TIA and RID (r(2) = 0.63, 0.62, respectively). When FPT was defined as serum IgG < 10 g/L, Brix % ≤ 8.5% showed optimal sensitivity (100%) and specificity (89.2%) to predict FPT. At the same IgG cut-point, an STP value of ≤ 52 g/L showed a similar sensitivity (100%) and specificity (80.4%) to predict FPT. Brix refractometry predicted successful transfer of passive immunity in dairy calves, but further evaluation as a diagnostic tool for the diagnosis of FPT is warranted. Copyright © 2016. Published by Elsevier Ltd.
Konopka, Ewa; Ceregra, Aldona; Maciorkowska, Elzbieta; Surowska, Barbara; Trojanowska, Ilona; Roszko-Kirpsza, Izabela; Cukrowska, Bozena
2016-01-01
Sensitization to food allergens is a common condition in pediatric atopic dermatitis (AD). Recently, the multiple allergen simultaneous test (MAST) allowing for a comprehensive assessment of atopy has been developed, but the usefulness in young AD children is not known. The aim of this study was to determine IgE specificity in AD children using MAST and to compare the results for selected food allergens with the reference ImmunoCap system. The study enrolled 50 children up to 2 years old with a diagnosis of AD. IgE antibodies were measured with the MAST-immunoblots. Children with specific IgE levels ≥ 0.35 kU/L were identified as sensitized to allergens. Most often children were sensitized to food allergens (egg white and yolk, hazelnuts, potato, cow's milk proteins, wheat flour, codfish, and soybean), but a high percentage of them also had IgE antibodies against house dust mites (12%), grass (10%), and birch (10%). Eight percent of children were sensitized to domestic animals (cats and dogs). Almost perfect (kappa index 0.8 - 1.0) and substantial (kappa index 0.6 - 0.8) agreement between MAST and ImmunoCap was found for food allergens except codfish. Pearson's analysis of antibody classes showed a very strong correlation between two methods (r = 0.8 - 1.0) for egg white, hazelnuts, potato, cow's milk proteins, wheat flour, and soybean, and a strong correlation (r = 0.6 - 0.79) was observed for peanut, egg yolk, and codfish. The study showed the frequent occurrence of IgE antibodies against food and airborne and animal allergens in young AD children and confirmed the usefulness of MAST-immunoblots for screening of sensitization in pediatric patients.
López-Muñoz, F; García-García, P; Alamo, C
2009-02-01
Before the National Socialist party came to power, the German pharmaceutical industry constituted an international reference as far as the development of new medicines was concerned, having been responsible for synthetic analgesics (phenacetin, phenazones, acetylsalicylic acid), arsphenamine, barbiturates and sulfonamides. The year 1925 saw the founding of I.G. Farben (Interessen-Gemeinschaft Farbenindustrie AG), a conglomerate of companies that would monopolize the country's chemical production and come to own all its major pharmaceutical industries. During the World War II, I.G. Farben participated in numerous operations associated with the criminal activities of the Nazi executive, including the use of slave labour in plants built close to concentration camps, such as that at Auschwitz. With regard to medical and pharmacological research projects, I.G. Farben became involved in experimental programmes using patients from the Nazi regime's euthanasia programmes and healthy subjects recruited without their consent from concentration camps, on whom various pharmacological substances were tested, including sulfamide and arsenical derivatives and other preparations whose composition is not precisely known (B-1012, B-1034, 3382 or Rutenol, 3582 or Acridine), generally in relation to the treatment of infectious diseases, such as typhus, erysipelas, scarlet fever or paratyphoid diarrhoea. Furthermore, I.G. Farben played a decisive role in the German army's chemical warfare programme, contributing to the development of the first two neurotoxic substances, later known as 'nerve agents', tabun and sarin. Some of these activities came to light as a result of the one the famous Nuremberg Trials in 1947, which saw 24 executives and scientists from I.G. Farben brought to justice for, among other offences, the use of slave labour in the concentration camps and forced experimentation with drugs on prisoners.
Boylan, Brian; Rice, Anne S.; Dunn, Amy L.; Tarantino, Michael D.; Brettler, Doreen B.; Barrett, John C.; Miller, Connie H.
2015-01-01
Summary Background The development of neutralizing antibodies, referred to as inhibitors, against factor VIII (FVIII) is a major complication associated with FVIII infusion therapy for the treatment of hemophilia A (HA). Previous studies have shown that a subset of HA patients and a low percentage of healthy individuals harbor non-neutralizing anti-FVIII antibodies that do not elicit the clinical manifestations associated with inhibitor development. Objective Assess HA patients' anti-FVIII antibody profiles as potential predictors of clinical outcomes. Methods A fluorescence immunoassay (FLI) was used to detect anti-FVIII antibodies in 491 samples from 371 HA patients. Results Assessments of antibody profiles showed that the presence of anti-FVIII IgG1, IgG2, or IgG4 correlated qualitatively and quantitatively with the presence of a FVIII inhibitor as reported by the Nijmegen-Bethesda assay (NBA). Forty-eight patients with a negative inhibitor history contributed serial samples to the study, including seven patients who had negative NBA titers initially and later converted to NBA-positive. The FLI detected anti-FVIII IgG1 in five of those seven patients prior to their conversion to NBA-positive. Five of 15 serial-sample patients who had a negative inhibitor history and a positive anti-FVIII IgG1 later developed an inhibitor, compared to 2 of 33 patients with a negative inhibitor history without anti-FVIII IgG1. Conclusions These data provide a rationale for future studies designed both to monitor the dynamics of anti-FVIII antibody profiles in HA patients as a potential predictor of future inhibitor development and to assess the value of the anti-FVIII FLI as a supplement to traditional inhibitor testing. PMID:25354263
Development of an anti-dengue NS1 IgG ELISA to evaluate exposure to dengue virus.
Nascimento, Eduardo J M; George, James K; Velasco, Melissa; Bonaparte, Matthew I; Zheng, Lingyi; DiazGranados, Carlos A; Marques, Ernesto T A; Huleatt, James W
2018-07-01
Dengue virus infection elicits immune responses to multiple viral antigens including antibodies to dengue non-structural protein 1 (NS1) which are rapidly induced and detected within days of infection. The recombinant, live, attenuated, tetravalent dengue vaccine (CYD-TDV; Sanofi Pasteur) uses the yellow fever vaccine virus as a back-bone but expresses dengue virus pre-membrane and envelop proteins. Since CYD-TDV does not express dengue NS1, we evaluated the utility of dengue NS1-specific IgG antibodies as biomarkers of dengue exposure in CYD-TDV recipients and controls. We optimized and evaluated a quantitative anti-dengue NS1 IgG enzyme-linked immunosorbent assay (ELISA). Parameters assessed included: accuracy, dilutability/linearity, precision, limit of quantitation and specificity. The assay specificity was further evaluated using Japanese Encephalitis virus, West Nile virus, Yellow Fever virus or Zika virus positive sera samples collected following confirmed infection or vaccination. Receiver-operating-characteristics (ROC) curves as well as sensitivity and specificity for discriminating previous dengue exposure were assessed using 1250 reference samples. Overall, the anti-dengue NS1 IgG ELISA was able to discriminate previous dengue exposure from non-exposure before vaccination with CYD-TDV (ROC area under the curve > 0.9). Assessment of paired samples from 2511 vaccinated participants showed high overall agreement (93%) between pre-vaccination and post-vaccination dengue serostatus classification based on the anti-dengue NS1 IgG ELISA. However, misclassification of dengue serostatus was observed after vaccination likely due to a combination of asymptomatic dengue infections, assay variability and a modest effect of CYD-TDV on the anti-dengue NS1 IgG ELISA readout. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Augner, Christoph; Hacker, Gerhard W
2009-12-01
Coeval with the expansion of mobile phone technology and the associated obvious presence of mobile phone base stations, some people living close to these masts reported symptoms they attributed to electromagnetic fields (EMF). Public and scientific discussions arose with regard to whether these symptoms were due to EMF or were nocebo effects. The aim of this study was to find out if people who believe that they live close to base stations show psychological or psychobiological differences that would indicate more strain or stress. Furthermore, we wanted to detect the relevant connections linking self-estimated distance between home and the next mobile phone base station (DBS), daily use of mobile phone (MPU), EMF-health concerns, electromagnetic hypersensitivity, and psychological strain parameters. Fifty-seven participants completed standardized and non-standardized questionnaires that focused on the relevant parameters. In addition, saliva samples were used as an indication to determine the psychobiological strain by concentration of alpha-amylase, cortisol, immunoglobulin A (IgA), and substance P. Self-declared base station neighbors (DBS = 100 meters) had significantly higher concentrations of alpha-amylase in their saliva, higher rates in symptom checklist subscales (SCL) somatization, obsessive-compulsive, anxiety, phobic anxiety, and global strain index PST (Positive Symptom Total). There were no differences in EMF-related health concern scales. We conclude that self-declared base station neighbors are more strained than others. EMF-related health concerns cannot explain these findings. Further research should identify if actual EMF exposure or other factors are responsible for these results.
NASA Astrophysics Data System (ADS)
Li, Zishen; Wang, Ningbo; Li, Min; Zhou, Kai; Yuan, Yunbin; Yuan, Hong
2017-04-01
The Earth's ionosphere is part of the atmosphere stretching from an altitude of about 50 km to more than 1000 km. When the Global Navigation Satellite System (GNSS) signal emitted from a satellite travels through the ionosphere before reaches a receiver on or near the Earth surface, the GNSS signal is significantly delayed by the ionosphere and this delay bas been considered as one of the major errors in the GNSS measurement. The real-time global ionospheric map calculated from the real-time data obtained by global stations is an essential method for mitigating the ionospheric delay for real-time positioning. The generation of an accurate global ionospheric map generally depends on the global stations with dense distribution; however, the number of global stations that can produce the real-time data is very limited at present, which results that the generation of global ionospheric map with a high accuracy is very different when only using the current stations with real-time data. In view of this, a new approach is proposed for calculating the real-time global ionospheric map only based on the current stations with real-time data. This new approach is developed on the basis of the post-processing and the one-day predicted global ionospheric map from our research group. The performance of the proposed approach is tested by the current global stations with the real-time data and the test results are also compared with the IGS-released final global ionospheric map products.
Dengue disease status in Chennai (2006-2008): A retrospective analysis
Gunasekaran, P.; Kaveri, K.; Mohana, S.; Arunagiri, Kavita; Babu, B.V. Suresh; Priya, P. Padma; Kiruba, R.; Kumar, V. Senthil; Sheriff, A. Khaleefathullah
2011-01-01
Background & objectives: Dengue is one of the most important Arboviral diseases in man with outbreaks in Southeast Asia and India. We report a retrospective analysis of the dengue positivity in the referred samples for three years period (2006 to 2008) at the Department of Virology, King Institute of Preventive Medicine, Chennai, Tamil Nadu, India. Methods: Serum samples from 1593 suspected cases (968 male and 625 female) were obtained. Of the 1593 cases screened, 1204 (75.5%) were paediatric cases and 389 (24.4%) adults. The samples were subjected to MAC ELISA and IgG ELISA. Results: Of the 968 patients, 686 (43.0%) were positive, of which 579 (84.0%) were in the paediatric age group (<14 yr) and 107 (15.5%) were adults. The IgM positivity being 356 (36.7%) in males and 330 (52.8%) in females. Of the 686 positives, 113 (16.47%) were positive for both IgM and IgG denoting secondary infection. There was a noticeable increased occurrence during the cooler months and during the monsoon and post-monsoon months. Interpretation & conclusions: The dengue IgM seropositivity among the suspected cases indicates active dengue virus activity. Increase in the probable secondary infections especially in a country like ours where multiple serotypes are prevalent raises concern over probable increase in the incidence of the more serious DHF/DSS. Studies need to be done to identify circulating serotypes of dengue virus to design preventive strategies. PMID:21441688
Lynch, D M; Leali, B A; Howe, S E
1986-08-01
An enzyme-linked immunosorbent assay (ELISA) that quantitates antisperm antibody in serum was compared with standard sperm agglutination and immobilization assays with the use of sera from 40 normal and 292 subfertile individuals. Quantitation of the assay was accomplished by standardizing assay parameters, including the incorporation of a standard reference curve, the number of whole target sperm, the optimal dilution of serum, the selection of microtiter plate, and the time and temperatures involved in the adsorption and incubation phases. With this method, the level of antisperm antibody binding to target sperm in 40 normal fertile individuals was found to be 2.3 (+/- 1.1 standard deviation [SD]) fg immunoglobulin (Ig)/sperm. An increased mean level of 7.4 +/- 3.7 fg Ig/sperm was determined in 84 infertile patients with positive agglutination and/or immobilization tests. In 208 individuals with negative agglutination and immobilization tests the mean concentration of antisperm antibody was 2.5 +/- 1.3 fg Ig/sperm. Postvasectomy patients assayed by this method had a mean Ig binding value of 7.1 +/- 2.4 fg Ig/sperm. The infertile group with positive agglutination and/or immobilization tests had a significantly higher mean antisperm antibody level than the normal fertile group, according to the Student's t-test for independent samples (P less than 0.001). This indirect serum-based assay reproducibly quantitates antisperm antibody binding to whole target sperm, suggests the normal and abnormal levels of antisperm antibody, and correlates with standard functional assays.
Molecular characterization of hepatitis E virus in patients with acute hepatitis in Venezuela.
García, Cristina Gutiérrez; Sánchez, Doneyla; Villalba, Maria Caridad Montalvo; Pujol, Flor Helene; de Los Ángeles Rodríguez Lay, Licel; Pinto, Belquis; Chacón, Elsa Patricia; Guzmán, Maria Guadalupe
2012-07-01
Hepatitis E virus (HEV) causes a common infection in developing countries. HEV infection occurs as outbreaks, as sporadic clinical cases and as large epidemics in endemic areas. The objective of this study was to determine the presence of HEV infection in patients with clinical suspicion of hepatitis A virus (HAV) infection, referred to the Instituto Nacional de Higiene "Rafael Rangel" in Venezuela. Seventy-four sera were tested for anti-HAV and anti-HEV IgM antibodies. HEV-RNA was amplified from anti-HEV IgM positive sera using nested reverse transcription polymerase chain reaction for ORF1 (RNA dependent RNA polymerase region) and the amplicons sequenced for phylogenetic analysis. The frequency of anti-HEV IgM was 22/74 (30%) in the samples tested. Dual infection with HAV and HEV was found in 31% (12/39) of anti-HAV IgM positive patients. Viremia was detected in 3/22 (14%) of sera positive for anti-HEV IgM. Two HEV strains were classified as genotype 1 and one as genotype 3, which were closely related to Yam 67 (north of India) and US1 isolates from the USA, respectively. These findings suggest that HEV is an important cause of acute viral hepatitis in Venezuela as a single infection or co-infection with HAV, with high morbidity in children and young adults suggesting that this infection is endemic in Venezuela. Copyright © 2012 Wiley Periodicals, Inc.
Lin, H Y; Masso-Welch, P; Di, Y P; Cai, J W; Shen, J W; Subjeck, J R
1993-01-01
Anoxia, glucose starvation, calcium ionophore A23187, EDTA, glucosamine, and several other conditions that adversely affect the function of the endoplasmic reticulum (ER) induce the synthesis of the glucose-regulated class of stress proteins (GRPs). The primary GRPs induced by these stresses migrate at 78 and 94 kDa (GRP78 and GRP94). In addition, another protein of approximately 150-170 kDa (GRP170) has been previously observed and is coordinately induced with GRP78 and GRP94. To characterize this novel stress protein, we have prepared an antisera against purified GRP170. Immunofluorescence, Endoglycosidase H sensitivity, and protease resistance of this protein in microsomes indicates that GRP170 is an ER lumenal glycoprotein retained in a pre-Golgi compartment. Immunoprecipitation of GRP170 with our antibody coprecipitates the GRP78 (also referred to as the B cell immunoglobulin-binding protein) and GRP94 members of this stress protein family in Chinese hamster ovary cells under stress conditions. ATP depletion, by immunoprecipitation in the presence of apyrase, does not affect the interaction between GRP78 and GRP170 but results in the coprecipitation of an unidentified 60-kDa protein. In addition, GRP170 is found to be coprecipitated with immunoglobulin (Ig) in four different B cell hybridomas expressing surface IgM, cytoplasmic Ig light chain only, cytoplasmic Ig heavy chain only, or an antigen specific secreted IgG. In addition, in IgM surface expressing WEHI-231 B cells, anti-IgM coprecipitates GRP78, GRP94, as well as GRP170; antibodies against GRP170 and GRP94 reciprocally coprecipitate GRP94/GRP170 as well as GRP78. Results suggest that this 170-kDa GRP is a retained ER lumenal glycoprotein that is constitutively present and that may play a role in immunoglobulin folding and assembly in conjunction or consecutively with GRP78 and GRP94. Images PMID:8305733
Status of NGS CORS Network and Its Contribution to the GGOS Infrastructure
NASA Astrophysics Data System (ADS)
Choi, K. K.; Haw, D.; Sun, L.
2017-12-01
Recent advancement of Satellite Geodesy techniques can now contribute to the global frame realization needed to improve worldwide accuracies. These techniques rely on coordinates computed using continuously observed GPS data and corresponding satellite orbits. The GPS-based reference system continues to depend on the physical stability of a ground-based network of points as the primary foundation for these observations. NOAA's National Geodetic Survey (NGS) has been operating Continuously Operating Reference Stations (CORS) to provide direct access to the National Spatial Reference System (NSRS). By virtue of NGS' scientific reputation and leadership in national and international geospatial issues, NGS has determined to increase its participation in the maintenance of the U.S. component of the global GPS tracking network in order to realize a long-term stable national terrestrial reference frame. NGS can do so by leveraging its national leadership role coupled with NGS' scientific expertise, in designating and upgrading a subset of the current tracking network for this purpose. This subset of stations must have the highest operational standards to serve the dual functions: being the U.S. contribution to the international frame, along with providing the link to the national datum. These stations deserve special attention to ensure that the highest possible levels of quality and stability are maintained. To meet this need, NGS is working with the international scientific groups to add and designate these reference stations based on scientific merit such as: colocation with other geodetic techniques, geographic area, and monumentation stability.
Spatial interpolation of daily reference evapotranspiration in the Texas High Plains
USDA-ARS?s Scientific Manuscript database
The Texas High Plains Evapotranspiration (ET) Network collects meteorological data from 18 grass reference weather stations at hourly intervals and estimates hourly and daily reference ET using the American Society of Civil Engineers (ASCE) Standardized Reference ET equation. Producers in the Texas ...
On the relevance of source effects in geomagnetic pulsations for induction soundings
NASA Astrophysics Data System (ADS)
Neska, Anne; Tadeusz Reda, Jan; Leszek Neska, Mariusz; Petrovich Sumaruk, Yuri
2018-03-01
This study is an attempt to close a gap between recent research on geomagnetic pulsations and their usage as source signals in electromagnetic induction soundings (i.e., magnetotellurics, geomagnetic depth sounding, and magnetovariational sounding). The plane-wave assumption as a precondition for the proper performance of these methods is partly violated by the local nature of field line resonances which cause a considerable portion of pulsations at mid latitudes. It is demonstrated that and explained why in spite of this, the application of remote reference stations in quasi-global distances for the suppression of local correlated-noise effects in induction arrows is possible in the geomagnetic pulsation range. The important role of upstream waves and of the magnetic equatorial region for such applications is emphasized. Furthermore, the principal difference between application of reference stations for local transfer functions (which result in sounding curves and induction arrows) and for inter-station transfer functions is considered. The preconditions for the latter are much stricter than for the former. Hence a failure to estimate an inter-station transfer function to be interpreted in terms of electromagnetic induction, e.g., because of field line resonances, does not necessarily prohibit use of the station pair for a remote reference estimation of the impedance tensor.
First Results of Field Absolute Calibration of the GPS Receiver Antenna at Wuhan University.
Hu, Zhigang; Zhao, Qile; Chen, Guo; Wang, Guangxing; Dai, Zhiqiang; Li, Tao
2015-11-13
GNSS receiver antenna phase center variations (PCVs), which arise from the non-spherical phase response of GNSS signals have to be well corrected for high-precision GNSS applications. Without using a precise antenna phase center correction (PCC) model, the estimated position of a station monument will lead to a bias of up to several centimeters. The Chinese large-scale research project "Crustal Movement Observation Network of China" (CMONOC), which requires high-precision positions in a comprehensive GPS observational network motived establishment of a set of absolute field calibrations of the GPS receiver antenna located at Wuhan University. In this paper the calibration facilities are firstly introduced and then the multipath elimination and PCV estimation strategies currently used are elaborated. The validation of estimated PCV values of test antenna are finally conducted, compared with the International GNSS Service (IGS) type values. Examples of TRM57971.00 NONE antenna calibrations from our calibration facility demonstrate that the derived PCVs and IGS type mean values agree at the 1 mm level.
Modeling and Assessment of GPS/BDS Combined Precise Point Positioning.
Chen, Junping; Wang, Jungang; Zhang, Yize; Yang, Sainan; Chen, Qian; Gong, Xiuqiang
2016-07-22
Precise Point Positioning (PPP) technique enables stand-alone receivers to obtain cm-level positioning accuracy. Observations from multi-GNSS systems can augment users with improved positioning accuracy, reliability and availability. In this paper, we present and evaluate the GPS/BDS combined PPP models, including the traditional model and a simplified model, where the inter-system bias (ISB) is treated in different way. To evaluate the performance of combined GPS/BDS PPP, kinematic and static PPP positions are compared to the IGS daily estimates, where 1 month GPS/BDS data of 11 IGS Multi-GNSS Experiment (MGEX) stations are used. The results indicate apparent improvement of GPS/BDS combined PPP solutions in both static and kinematic cases, where much smaller standard deviations are presented in the magnitude distribution of coordinates RMS statistics. Comparisons between the traditional and simplified combined PPP models show no difference in coordinate estimations, and the inter system biases between the GPS/BDS system are assimilated into receiver clock, ambiguities and pseudo-range residuals accordingly.
Alessandri, C; Zennaro, D; Scala, E; Ferrara, R; Bernardi, M Livia; Santoro, M; Palazzo, P; Mari, A
2012-03-01
Egg allergy is a very common finding in early childhood. Detecting hen's egg (HE) allergy outgrowing and reintroduction of food containing egg is a task for the allergist. We sought to evaluate the suitability of boiled egg food challenge compared with IgE to allergenic molecules from HE white using a microarray system. Sixty-eight children referring to our centre by the family paediatricians for a suspected egg allergy were enrolled. Patients underwent double-blind, placebo-controlled food challenge with boiled and raw eggs. Challenge outcomes were compared with skin tests performed using egg white and yolk commercial extracts, to prick-prick test with boiled and raw egg white and yolk, total IgE, egg white specific IgE detected using ImmunoCAP and IgE to egg allergens available on the immunosolid phase allergen chip (ISAC) 103 microarray. Nineteen subjects (28%) were reactive to both raw and boiled egg, 14 (20.5%) to raw egg only and 35 (51.4%) tolerated both boiled and raw egg. Efficiency analysis was carried out using both raw and boiled egg challenges as gold standard. Forty four of 47 Gal d 1 negative patients tolerated boiled egg (94%). Conversely, 20 of 21 Gal d 1 positive patients reacted to raw egg (95%). None of the other tests was able to discriminate patients' response to HE challenge. Furthermore, Gal d 1 positivity seems to lead to broader environmental allergen IgE sensitization. The Gal d 1 IgE reactivity appears to be a very good predictor of HE clinical allergy. Gal d 1 positive children have a high frequency of HE allergy, whereas Gal d 1 negative children have a high frequency of tolerance to boiled egg. Multiple specific IgE detection by means of ISAC improves the diagnostic approach in HE allergic children, disclosing other food and inhalant allergic sensitizations, anyhow requiring a comprehensive clinical evaluation. © 2011 Blackwell Publishing Ltd.
Combined orbits and clocks from IGS second reprocessing
NASA Astrophysics Data System (ADS)
Griffiths, Jake
2018-05-01
The Analysis Centers (ACs) of the International GNSS Service (IGS) have reprocessed a large global network of GPS tracking data from 1994.0 until 2014.0 or later. Each AC product time series was extended uniformly till early 2015 using their weekly operational IGS contributions so that the complete combined product set covers GPS weeks 730 through 1831. Three ACs also included GLONASS data from as early as 2002 but that was insufficient to permit combined GLONASS products. The reprocessed terrestrial frame combination procedures and results have been reported already, and those were incorporated into the ITRF2014 multi-technique global frame released in 2016. This paper describes the orbit and clock submissions and their multi-AC combinations and assessments. These were released to users in early 2017 in time for the adoption of IGS14 for generating the operational IGS products. While the reprocessing goal was to enable homogeneous modeling, consistent with the current operational procedures, to be applied retrospectively to the full history of observation data in order to achieve a more suitable reference for geophysical studies, that objective has only been partially achieved. Ongoing AC analysis changes and a lack of full participation limit the consistency and precision of the finished IG2 products. Quantitative internal measures indicate that the reprocessed orbits are somewhat less precise than current operational orbits or even the later orbits from the first IGS reprocessing campaign. That is even more apparent for the clocks where a lack of robust AC participation means that it was only possible to form combined 5-min clocks but not the 30-s satellite clocks published operationally. Therefore, retrospective precise point positioning solutions by users are not recommended using the orbits and clocks. Nevertheless, the orbits do support long-term stable user solutions when used with network processing with either double differencing or explicit clock estimation. Among the main benefits of the reprocessing effort is a more consistent long product set to analyze for sources of systematic error and accuracy. Work to do that is underway but the reprocessing experience already points to a number of ways future IGS performance and reprocessing campaigns can be improved.
Shalel Levanon, Sagit; Aharonovitz, Orit; Maor-Shoshani, Ayelet; Abraham, Gita; Kenett, Dan; Aloni, Yehoshua
2018-06-20
Glycosylation on the Fc region of recombinant Immunoglobulin G (IgG) therapeutic antibodies is a critical protein quality attribute which may affect the efficacy and safety of the molecule. During the development of biosimilar therapeutics, adjustment of the glycosylation profile is required in order to match the reference innovator profile. Deoxymannojirimycin (DMJ), a known inhibitor of mannosidase, was used in this study to modulate the glycosylation pattern of antibodies. The effect of DMJ, at concentrations of 5 μM - 500 μM, on non-fucosylated glycoform levels was tested in the biosynthesis processes of two different IgG1 (IgG1 #A and IgG1 #B) using two Chinese hamster ovary (CHO) cell lines (CHO-DXB-11 and CHOK1SV, respectively) in Erlenmeyer flasks and in lab scale bioreactors. DMJ affected glycan forms in a dose response manner. At the highest concentration tested, DMJ reduced N-linked complex glycoform and core fucose levels by 15 and 14 fold, respectively, and increased high mannose level by 21 fold. 10 μM DMJ decreased IgG1 #A core fucose level in CHO-DXB-11 from 92% to 73% and increased high mannose level from 4% to 22% in Erlenmeyer flasks. Furthermore, in lab scale bioreactors, 15 μM DMJ decreased IgG1 #A core fucose level from 95% to 84% and increased high mannose level from 3% to 13%. Core fucose level of IgG1 #B in CHOK1SV was decreased from 81% to 73% using 10 μM DMJ in lab scale bioreactors while high mannose was increased from 6% to 15%. While affecting core fucose and high mannose levels, DMJ decreased maximum viable cell concentration by 16% and did not significantly affect cell productivity (less than 10%). This study demonstrated that DMJ can enable the control of core fucosylated and high mannose levels of IgG1 antibodies in a defined range. Copyright © 2018 Elsevier B.V. All rights reserved.
Levanov, Lev; Vera, Cristina Pérez; Vapalahti, Olli
2016-07-01
Tick-borne encephalitis (TBE) is one of the most dangerous human neurological infections occurring in Europe and Northern parts of Asia with thousands of cases and millions vaccinated against it. The risk of TBE might be assessed through analyses of the samples taken from wildlife or from animals which are in close contact with humans. Dogs have been shown to be a good sentinel species for these studies. Serological assays for diagnosis of TBE in dogs are mainly based on purified and inactivated TBEV antigens. Here we describe novel dog anti-TBEV IgG monoclonal antibody (MAb)-capture assay which is based on TBEV prME subviral particles expressed in mammalian cells from Semliki Forest virus (SFV) replicon as well as IgG immunofluorescence assay (IFA) which is based on Vero E6 cells transfected with the same SFV replicon. We further demonstrate their use in a small-scale TBEV seroprevalence study of dogs representing different regions of Finland. Altogether, 148 dog serum samples were tested by novel assays and results were compared to those obtained with a commercial IgG enzyme immunoassay (EIA), hemagglutination inhibition test and IgG IFA with TBEV infected cells. Compared to reference tests, the sensitivities of the developed assays were 90-100% and the specificities of the two assays were 100%. Analysis of the dog serum samples showed a seroprevalence of 40% on Åland Islands and 6% on Southwestern archipelago of Finland. In conclusion, a specific and sensitive EIA and IFA for the detection of IgG antibodies in canine sera were developed. Based on these assays the seroprevalence of IgG antibodies in dogs from different regions of Finland was assessed and was shown to parallel the known human disease burden as the Southwestern archipelago and Åland Islands in particular had considerable dog TBEV antibody prevalence and represent areas with high risk of TBE for humans. Copyright © 2016 Elsevier GmbH. All rights reserved.
NASA Astrophysics Data System (ADS)
Geng, J.; Bock, Y.; Melgar, D.; Hasse, J.; Crowell, B. W.
2013-12-01
High-rate GPS can play an important role in earthquake early warning (EEW) systems for large (>M6) events by providing permanent displacements immediately as they are achieved, to be used in source inversions that can be repeatedly updated as more information becomes available. This is most valuable to implement at a site very near the potential source rupture, where broadband seismometers are likely to clip, and accelerometer data cannot be objectively integrated to produce reliable displacements in real time. At present, more than 525 real-time GPS stations have been established in western North America, which are being integrated into EEW systems. Our analysis technique relies on a tightly-coupled combination of GPS and accelerometer data, an extension of precise point positioning with ambiguity resolution (PPP-AR). We operate a PPP service based on North American stations available through the IGS and UNAVCO/PBO. The service provides real-time satellite clock and fractional-cycle bias products that allow us to position individual client stations in the zone of deformation. The service reference stations are chosen to be further than 200 km from the primary zones of tectonic deformation in the western U.S. to avoid contamination of the satellite products during a large seismic event. At client stations, accelerometer data are applied as tight constraints on the positions between epochs in PPP-AR, which improves cycle-slip repair and rapid ambiguity resolution after GPS outages. Furthermore, we estimate site displacements, seismic velocities, and coseismic ground tilts to facilitate the analysis of ground motion characteristics and the inversion for source mechanisms. The seismogeodetic displacement and velocity waveforms preserves the detection of P wave arrivals, and provides P-wave arrival displacement that is key new information for EEW. Our innovative solution method for coseismic tilts mitigates an error source that has continually plagued strong motion data analysis, and has a resolution of about 0.01 degrees. At present, there are few collocations of GPS and accelerometers in western North America (the exception being the BARD network in northern California) so we have developed a cost-effective way to upgrade existing real-time GPS stations with low-cost MEMS accelerometers; fifteen PBO and SCIGN stations in southern California have already been upgraded. We demonstrate our method of recovering broadband displacement and tilt waveforms using 13 experiments from the single-axis George E. Brown Jr. Network for Earthquake Engineering Simulation Large High-Performance Outdoor Shake Table at the University of California San Diego. Then we apply the method to data from the 2010 Mw 7.2 El Mayor-Cucapah earthquake and the 2011 Mw 9.0 Tohoku-oki earthquake to illustrate the improvement over standard base-line correction acceleration techniques and to demonstrate the order of magnitude of tilt errors present in typical observations.
Lupin sensitization and clinical allergy in food allergic children in Norway.
Lindvik, Helene; Holden, Lise; Løvik, Martinus; Cvancarova, Milada; Halvorsen, Ragnhild
2008-01-01
The aim of the present pilot study was to investigate to what extent children in Norway sensitized to lupin had clinical lupin allergy, and to compare sensitization to lupin with sensitization to other legumes. Thirty-five children with food allergy referred to a national referral hospital were evaluated with skin prick test (SPT) and analysis of serum-specific IgE to lupin, peanut, pea and soy. The children with positive SPTs to lupin were offered oral food challenges with lupin flour. Fifteen children (43%) had positive SPT and 17 children (49%) had serum-specific IgE to lupin. Ten SPT-positive children underwent oral food challenges and one experienced an allergic reaction to lupin flour. This child was one of six challenged children with IgE antibodies to peanut >15 kU(A)/L. There was a strong relationship between positive SPT to lupin flour and positive SPT to soy and between positive SPT to lupin and specific IgE to soy, pea and peanut. Children with sensitization to lupin are not likely to have a clinical lupin allergy. Avoidance of lupin on the basis of lupin sensitization or peanut allergy would lead to unnecessarily strict diets. Food challenge is currently necessary to diagnose lupin allergy.
Foley, P T; Kavnoudias, H; Cameron, P U; Czarnecki, C; Paul, E; Lyon, S M
2015-10-01
To compare the impact of proximal or distal splenic artery embolisation versus that of splenectomy on splenic immune function as measured by IgM memory B cell levels. Patients with splenic trauma who were treated by splenic artery embolisation (SAE) were enrolled. After 6 months splenic volume was assessed by CT, and IgM memory B cells in peripheral blood were measured and compared to a local normal reference population and to a post-splenectomy population. Of the 71 patients who underwent embolisation, 38 underwent proximal embolisation, 11 underwent distal embolisation, 22 patients were excluded, 1 had both proximal and distal embolisation, 5 did not survive and 16 did not return for evaluation. There was a significant difference between splenectomy and proximal or distal embolisation and a trend towards greater preservation of IgM memory B cell number in those with distal embolisation-a difference that could not be attributed to differences in age, grade of injury or residual splenic volume. IgM memory B cell levels are significantly higher in those treated with SAE compared to splenectomy. Our data provide evidence that splenic embolisation should reduce immunological complications of spleen trauma and suggest that distal embolisation may maintain better function.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Foley, P. T., E-mail: pfoley@doctors.org.uk; Kavnoudias, H., E-mail: h.kavnoudias@alfred.org.au; Cameron, P. U., E-mail: paul.cameron@unimelb.edu.au
PurposeTo compare the impact of proximal or distal splenic artery embolisation versus that of splenectomy on splenic immune function as measured by IgM memory B cell levels.Materials and MethodsPatients with splenic trauma who were treated by splenic artery embolisation (SAE) were enrolled. After 6 months splenic volume was assessed by CT, and IgM memory B cells in peripheral blood were measured and compared to a local normal reference population and to a post-splenectomy population.ResultsOf the 71 patients who underwent embolisation, 38 underwent proximal embolisation, 11 underwent distal embolisation, 22 patients were excluded, 1 had both proximal and distal embolisation, 5 didmore » not survive and 16 did not return for evaluation. There was a significant difference between splenectomy and proximal or distal embolisation and a trend towards greater preservation of IgM memory B cell number in those with distal embolisation—a difference that could not be attributed to differences in age, grade of injury or residual splenic volume.ConclusionIgM memory B cell levels are significantly higher in those treated with SAE compared to splenectomy. Our data provide evidence that splenic embolisation should reduce immunological complications of spleen trauma and suggest that distal embolisation may maintain better function.« less
Communication network for decentralized remote tele-science during the Spacelab mission IML-2
NASA Technical Reports Server (NTRS)
Christ, Uwe; Schulz, Klaus-Juergen; Incollingo, Marco
1994-01-01
The ESA communication network for decentralized remote telescience during the Spacelab mission IML-2, called Interconnection Ground Subnetwork (IGS), provided data, voice conferencing, video distribution/conferencing and high rate data services to 5 remote user centers in Europe. The combination of services allowed the experimenters to interact with their experiments as they would normally do from the Payload Operations Control Center (POCC) at MSFC. In addition, to enhance their science results, they were able to make use of reference facilities and computing resources in their home laboratory, which typically are not available in the POCC. Characteristics of the IML-2 communications implementation were the adaptation to the different user needs based on modular service capabilities of IGS and the cost optimization for the connectivity. This was achieved by using a combination of traditional leased lines, satellite based VSAT connectivity and N-ISDN according to the simulation and mission schedule for each remote site. The central management system of IGS allows minimization of staffing and the involvement of communications personnel at the remote sites. The successful operation of IGS for IML-2 as a precursor network for the Columbus Orbital Facility (COF) has proven the concept for communications to support the operation of the COF decentralized scenario.
Improving highway advisory radio predictability and performance
DOT National Transportation Integrated Search
2011-01-01
Highway Advisory Radio (HAR) stations, sometimes referred to as Travelers Information Stations (TIS), : allow highway agencies to broadcast important messages about traffic, weather and roadway conditions to : motorists. Caltrans has deployed HAR ...
Alvarez-Cuesta, E; Madrigal-Burgaleta, R; Angel-Pereira, D; Ureña-Tavera, A; Zamora-Verduga, M; Lopez-Gonzalez, P; Berges-Gimeno, M P
2015-07-01
Evidence regarding drug provocation test (DPT) with antineoplastic and biological agents is scarce. Our aim was to assess the usefulness of including DPT as a paramount gold standard diagnostic tool (prior to desensitization). Prospective, observational, longitudinal study with patients who, during a 3-year period, were referred to the Desensitization Program at Ramon y Cajal University Hospital. Patients underwent a structured diagnostic protocol by means of anamnesis, skin tests (ST), risk assessment, and DPT. Oxaliplatin-specific IgE was determined in oxaliplatin-reactive patients (who underwent DPT regardless of oxaliplatin-specific IgE results). Univariate analysis and multivariate analysis were used to identify predictors of the final diagnosis among several variables. A total of 186 patients were assessed. A total of 104 (56%) patients underwent DPT. Sixty-four percent of all DPTs were negative (i.e., hypersensitivity was excluded). Sensitivity for oxaliplatin-specific IgE (0.35 UI/l cutoff point) was 34%, specificity 90.3%, negative predictive value 45.9%, positive predictive value 85%, negative likelihood ratio 0.7, and positive likelihood ratio 3.5. These are the first reported data based on more than 100 DPTs with antineoplastic and biological agents (paclitaxel, oxaliplatin, rituximab, infliximab, irinotecan, and other drugs). Implementation of DPT in diagnostic protocols helps exclude hypersensitivity (in 36% of all referred patients), and avoids unnecessary desensitizations in nonhypersensitive patients (30-56% of patients, depending on culprit-drug). Drug provocation test is vital to validate diagnostic tools; consequently, quality data are shown on oxaliplatin-specific IgE and oxaliplatin-ST in the largest series of oxaliplatin-reactive patients reported to date (74 oxaliplatin-reactive patients). Identifying phenotypes and predictors of a diagnosis of hypersensitivity may be helpful for tailored plans. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Mankertz, Annette; Beutel, Ulrike; Schmidt, Franz-Josef; Borgmann, Stefan; Wenzel, Jürgen J; Ziegler, Peter; Weißbrich, Benedikt; Santibanez, Sabine
2015-10-01
From 2008 to 2013, sample sets from 534 patients displaying clinical symptoms of mumps were submitted to the German Reference Centre for Measles, Mumps and Rubella. Mumps virus infection was confirmed in 216 cases (40%) by PCR and/or serology. Confirmed cases were more frequently seen in male than in female patients (128 vs. 81); the age group predominantly affected was 15 to 29 years old (65%, median age: 26.4 years). The majority of the confirmed cases had a remote history of vaccination with one or two doses of a mumps-containing vaccine (69%). Our results indicate that mumps virus caused two outbreaks in Bavaria in 2008 and 2010/2011 and a third one in Lower Saxony in 2011. Mumps virus genotype G was preponderantly detected from 2008 to 2013. For 107 of the 216 patients with a confirmed mumps infection, we correlated the results from PCR and serology. PCR detected cases during the first week after onset of symptoms (74% positive results). PCR worked best with throat swabs and oral fluids (61% and 60% positive results, respectively). IgM was more reliable with a longer time after onset of symptoms (67%), but indirect IgM serology was of insufficient sensitivity for vaccinated mumps cases (30%); the IgM μ-capture assay detected more cases in this group. Mumps virus is able to initiate an infection in vaccinated patients (secondary vaccine failure, SVF) although it is unclear to what extent. Since SVF does occur in highly vaccinated populations and IgM will not increase to detectable levels in all SVF patients, we strongly recommend using PCR plus serology tests to avoid false-negative diagnoses in vaccinated individuals with clinical signs of mumps. Copyright © 2015 Elsevier GmbH. All rights reserved.
Global Application of TaiWan Ionospheric Model to Single-Frequency GPS Positioning
NASA Astrophysics Data System (ADS)
Macalalad, E.; Tsai, L. C.; Wu, J.
2012-04-01
Ionospheric delay is one the major sources of error in GPS positioning and navigation. This error in both pseudorange and phase ranges vary depending on the location of observation, local time, season, solar cycle and geomagnetic activity. For single-frequency receivers, this delay is usually removed using ionospheric models. Two of them are the Klobuchar, or broadcast, model and the global ionosphere map (GIM) provided by the International GNSS Service (IGS). In this paper, a three dimensional ionospheric electron (ne) density model derived from FormoSat3/COSMIC GPS Radio Occultation measurements, called the TaiWan Ionosphere Model, is used. It was used to calculate the slant total electron content (STEC) between receiver and GPS satellites to correct the pseudorange single-frequency observations. The corrected pseudorange for every epoch was used to determine a more accurate position of the receiver. Observations were made in July 2, 2011(Kp index = 0-2) in five randomly selected sites across the globe, four of which are IGS stations (station ID: cnmr, coso, irkj and morp) while the other is a low-cost single-frequency receiver located in Chungli City, Taiwan (ID: isls). It was illustrated that TEC maps generated using TWIM exhibited a detailed structure of the ionosphere, whereas Klobuchar and GIM only provided the basic diurnal and geographic features of the ionosphere. Also, it was shown that for single-frequency static point positioning TWIM provides more accurate and more precise positioning than the Klobuchar and GIM models for all stations. The average %error of the corrections made by Klobuchar, GIM and TWIM in DRMS are 3.88%, 0.78% and 17.45%, respectively. While the average %error in VRMS for Klobuchar, GIM and TWIM are 53.55%, 62.09%, 66.02%, respectively. This shows the capability of TWIM to provide a good global 3-dimensional ionospheric model.
NASA Astrophysics Data System (ADS)
Czechowski, Piotr Oskar; Owczarek, Tomasz; Badyda, Artur; Majewski, Grzegorz; Rogulski, Mariusz; Ogrodnik, Paweł
2018-01-01
The paper presents selected preliminary stage key issues proposed extended equivalence measurement results assessment for new portable devices - the comparability PM10 concentration results hourly series with reference station measurement results with statistical methods. In article presented new portable meters technical aspects. The emphasis was placed on the comparability the results using the stochastic and exploratory methods methodology concept. The concept is based on notice that results series simple comparability in the time domain is insufficient. The comparison of regularity should be done in three complementary fields of statistical modeling: time, frequency and space. The proposal is based on model's results of five annual series measurement results new mobile devices and WIOS (Provincial Environmental Protection Inspectorate) reference station located in Nowy Sacz city. The obtained results indicate both the comparison methodology completeness and the high correspondence obtained new measurements results devices with reference.
Airborne and Maritime/Fixed Station Joint Tactical Radio System (AMF JTRS)
2015-12-01
Selected Acquisition Report (SAR) RCS: DD-A&T(Q&A)823-421 Airborne & Maritime/Fixed Station Joint Tactical Radio System (AMF JTRS) As of FY 2017...Information Program Name Airborne & Maritime/Fixed Station Joint Tactical Radio System (AMF JTRS) DoD Component Army Responsible Office References SAR...UNCLASSIFIED 5 Mission and Description Airborne & Maritime/Fixed Station Joint Tactical Radio System (AMF JTRS) products are software programmable
NASA Global GNSS Network (GGN) Status and Plans
NASA Astrophysics Data System (ADS)
Doelger, S.; Sklar, J.; Blume, F.; Meertens, C. M.; Mattioli, G. S.
2015-12-01
UNAVCO, in conjunction with JPL, is responsible for monitoring the 62 GNSS permanent stations, which include 88 GPS receivers, which comprise the NASA Global GNSS Network (GGN). These sites represent approximately 16% of the ~400 International GNSS Service (IGS) stations, and they provide a globally distributed GNSS network to support NASA operations and its commitments to GGOS. UNAVCO provides data flow monitoring, trouble-shooting, station installation, maintenance, as well as engineering services to improve the capabilities and performance of station infrastructure. Activities this past year include the installation of a geodetic quality wellhead monument for the new SEY2 station to replace SEY1, which is mounted on a UCSD seismic station in the Seychelles Islands. SEY1 will be removed soon to accommodate planned maintenance and upgrades by UCSD. Data from both SEY1 and SEY2 are being collected concurrently until maintenance begins. MRTG (Multi Router Traffic Grapher), a tool to aid in characterizing bandwidth usage and to identify communications problems, is now being used to monitor data throughput at 7 stations where VSAT or radio telemetry are used, including: ABPO; AREQ; FALK; GUAM; HARV; ISPA; QUIN; and STHL. Aging computers are being replaced with new hardware running Linux CentOS. These are semi-ruggedized low power solid-state systems built to endure challenging environments. With the aid of on-site collaborators, systems are now deployed at: FALK; CUSV; KELY; STHL; SANT; and ZAMB. Last, 4 new GPS stations were deployed for NASA's Space Geodesy Project (SGP); three of which (KOKF, KOKG, and KOKR) are located at Koke'e Park Geophysical Observatory on Kauai, Hawai'i, and HAL1 at the Haleakala observatory complex on Maui, Hawai'i. A campaign system was set up at Koke'e in order to sample data quality to determine if an additional station would be viable. Planning is ongoing for deployment of several new stations next year at McDonald Observatory (TX).
Isostatic gravity map of the Monterey 30 x 60 minute quadrangle and adjacent areas, California
Langenheim, V.E.; Stiles, S.R.; Jachens, R.C.
2002-01-01
The digital dataset consists of one file (monterey_100k.iso) containing 2,385 gravity stations. The file, monterey_100k.iso, contains the principal facts of the gravity stations, with one point coded per line. The format of the data is described below. Each gravity station has a station name, location (latitude and longitude, NAD27 projection), elevation, and an observed gravity reading. The data are on the IGSN71 datum and the reference ellipsoid is the Geodetic Reference System 1967 (GRS67). The free-air gravity anomalies were calculated using standard formulas (Telford and others, 1976). The Bouguer, curvature, and terrain corrections were applied to the free-air anomaly at each station to determine the complete Bouguer gravity anomalies at a reduction density of 2.67 g/cc. An isostatic correction was then applied to remove the long-wavelength effect of deep crustal and/or upper mantle masses that isostatically support regional topography.
Brier, S; Le Mignon, M; Jain, K; Lebrun, C; Peurois, F; Kellenberger, C; Bordas-Le Floch, V; Mascarell, L; Nony, E; Moingeon, P
2018-05-01
Accurate allergen quantification is needed to document the consistency of allergen extracts used for immunotherapy. Herein, we characterize the epitope specificities of two monoclonal antibodies used in an ELISA for the quantification of the major birch pollen allergen Bet v 1, established as a reference by the BSP090 European project. The ability of mAbs 5B4 and 6H4 to recognize Bet v 1 isoforms was addressed by immunochromatography. The capacity of each mAb to compete with patients' IgE for binding to Bet v 1 was measured by ELISA inhibition. Epitope mapping was performed by pepscan analysis, site-directed mutagenesis, and hydrogen/deuterium exchange-mass spectrometry. The 5B4 epitope corresponds to a peptide sequence (I56-K68) overlapping with the binding sites of patients' serum IgEs. Mutation of residues P59, E60, and K65 abolishes 5B4 binding to Bet v 1 and reduces the level of IgE recognition. In contrast, 6H4 recognizes a conformational epitope lying opposite to the 5B4 binding site, involving residues located in segments I44-K55 and R70-F79. Substitution of E45 reduces the binding capacity of 6H4, confirming that it is critical for the interaction. Both mAbs interact with >90% of Bet v 1 content present in the birch pollen extract, while displaying a weak cross-reactivity with other allergens of the PR-10 family. MAbs 5B4 and 6H4 recognize structurally distinct epitopes present in the vast majority of Bet v 1 isoforms. These results support the relevance as a reference method of the Bet v 1-specific quantitative ELISA adopted by the European Pharmacopoeia. © 2017 EAACI and John Wiley and Sons A/S. Published by John Wiley and Sons Ltd.
47 CFR 90.313 - Frequency loading criteria.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., Washington, or more from the location of base stations authorized on that pair without reference to loading... Industrial Radio Services, if the base station facility is to be used by more than a single licensee, the...
47 CFR 25.109 - Cross-reference.
Code of Federal Regulations, 2011 CFR
2011-10-01
... licensed under this part: (a) Amateur Satellite Service, see 47 CFR part 97. (b) Ship earth stations in the Maritime Mobile Satellite Service, see 47 CFR part 83. (c) Ship earth stations in the Maritime Mobile...
47 CFR 25.109 - Cross-reference.
Code of Federal Regulations, 2012 CFR
2012-10-01
... licensed under this part: (a) Amateur Satellite Service, see 47 CFR part 97. (b) Ship earth stations in the Maritime Mobile Satellite Service, see 47 CFR part 83. (c) Ship earth stations in the Maritime Mobile...
47 CFR 25.109 - Cross-reference.
Code of Federal Regulations, 2010 CFR
2010-10-01
... licensed under this part: (a) Amateur Satellite Service, see 47 CFR part 97. (b) Ship earth stations in the Maritime Mobile Satellite Service, see 47 CFR part 83. (c) Ship earth stations in the Maritime Mobile...
Stratus 12 Twelfth Setting of the Stratus Ocean Reference Station
2012-10-01
22 - June 4, 2012 Valparaiso, Chile - Galapagos Islands, Ecuador by Sebastien Bigorre,1 Robert A. Weller,1 Jeff Lord,1 Nancy Galbraith,1 Sean Whelan,1...Institution, Woods Hole, MA 2 Universidad de Concepción, Chile 3 FICOLAB, Universidad de Concepción, Chile 4 National observer, Ecuador 5...Ocean Reference Station at 20°S, 85°W under the stratus clouds west of northern Chile is being maintained to provide ongoing climate-quality records
Space station human productivity study. Volume 4: Issues
NASA Technical Reports Server (NTRS)
1985-01-01
The 305 Issues contained represent topics recommended for study in order to develop requirements in support of space station crew performance/productivity. The overall subject matter, space station elements affecting crew productivity, was organized into a coded subelement listing, which is included for the reader's reference. Each issue is numbered according to the 5-digit topical coding scheme. The requirements column on each Issue page shows a cross-reference to the unresolved requirement statement(s). Because topical overlaps were frequently encountered, many initial Issues were consolidated. Apparent gaps, therefore, may be accounted for by an Issue described within a related subelement. A glossary of abbreviations used throughout the study documentation is also included.
Deceiving proteins! A case of lymphoma and high creatinine.
Metraiah, El Hakem Abdelkarim; Regan, Helen; Louw, Johanna; Kidder, Dana
2017-01-23
Estimation of kidney function by measuring serum creatinine is one the commonest laboratory tests conducted in clinical practice. Enzymatic methods are often used to measure serum creatinine. Clinicians should be aware of the limitations of these methods, such as test interference with paraproteins.We present a case of falsely elevated serum creatinine in a patient referred for renal biopsy. The combination of fluctuating creatinine and normal blood urea level was unusual. Serum protein electrophoresis revealed the presence of an IgM paraprotein. Further investigations confirmed an underlying diagnosis of lymphoplasmacytoid lymphoma. This case highlights how IgM paraprotein can interfere with creatinine estimation by enzymatic assay and the utility of alternative methods of estimating serum creatinine. 2017 BMJ Publishing Group Ltd.
de Araújo, Tais Pinheiro; Rodrigues, Sueli Guerreiro; Costa, Maria Irene Weyl de A; Vasconcelos, Pedro Fernando da Costa; da Rosa, Amélia P A Travassos
2002-01-01
From June to December 1999, 785 serum samples were obtained from patients clinically suspected of having dengue or yellow fever. The patients were referred by public health centers distributed within the six mesoregions of Par State, Brazil. Serum samples were tested for Flavivirus antibodies by hemagglutination inhibition test and for dengue and yellow fever viruses by enzyme-linked immunosorbent assay for IgM detection. Of the sera collected, 563 (71.7%) were positive by HI test and out of these 150 (26.6%) were positive by ELISA-IgM. Dengue virus was responsible for most of the recent infections in all regions; yellow fever cases detected in the current study were restricted to the Maraj and Southeast regions.
NASA Technical Reports Server (NTRS)
1983-01-01
The capabilities of the European Space Agency's SPAS and EURECA platforms for reference payload accommodation are considered. The instrument pointing subsystem, the position and hold mount, and the antenna pointing mechanism developed by Dornier are described. Relevant payloads for the space station are summarized and space station accommodation aspects are discussed.
47 CFR 301.10 - Cross-reference.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false Cross-reference. 301.10 Section 301.10 Telecommunication NATIONAL TELECOMMUNICATIONS AND INFORMATION ADMINISTRATION, DEPARTMENT OF COMMERCE RELOCATION OF AND SPECTRUM SHARING BY FEDERAL GOVERNMENT STATIONS General Information § 301.10 Cross-reference. The...
47 CFR 301.10 - Cross-reference.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 5 2013-10-01 2013-10-01 false Cross-reference. 301.10 Section 301.10 Telecommunication NATIONAL TELECOMMUNICATIONS AND INFORMATION ADMINISTRATION, DEPARTMENT OF COMMERCE RELOCATION OF AND SPECTRUM SHARING BY FEDERAL GOVERNMENT STATIONS General Information § 301.10 Cross-reference. The...
H2FIRST Reference Station Design Task: Project Deliverable 2-2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pratt, Joseph; Terlip, Danny; Ainscough, Chris
2015-04-20
This report presents near-term station cost results and discusses cost trends of different station types. It compares various vehicle rollout scenarios and projects realistic near-term station utilization values using the station infrastructure rollout in California as an example. It describes near-term market demands and matches those to cost-effective station concepts. Finally, the report contains detailed designs for five selected stations, which include piping and instrumentation diagrams, bills of materials, and several site-specific layout studies that incorporate the setbacks required by NFPA 2, the National Fire Protection Association Hydrogen Technologies Code. This work identified those setbacks as a significant factor affectingmore » the ability to site a hydrogen station, particularly liquid stations at existing gasoline stations. For all station types, utilization has a large influence on the financial viability of the station.« less
ITG: A New Global GNSS Tropospheric Correction Model
Yao, Yibin; Xu, Chaoqian; Shi, Junbo; Cao, Na; Zhang, Bao; Yang, Junjian
2015-01-01
Tropospheric correction models are receiving increasing attentions, as they play a crucial role in Global Navigation Satellite System (GNSS). Most commonly used models to date include the GPT2 series and the TropGrid2. In this study, we analyzed the advantages and disadvantages of existing models and developed a new model called the Improved Tropospheric Grid (ITG). ITG considers annual, semi-annual and diurnal variations, and includes multiple tropospheric parameters. The amplitude and initial phase of diurnal variation are estimated as a periodic function. ITG provides temperature, pressure, the weighted mean temperature (Tm) and Zenith Wet Delay (ZWD). We conducted a performance comparison among the proposed ITG model and previous ones, in terms of meteorological measurements from 698 observation stations, Zenith Total Delay (ZTD) products from 280 International GNSS Service (IGS) station and Tm from Global Geodetic Observing System (GGOS) products. Results indicate that ITG offers the best performance on the whole. PMID:26196963
MODEL-BASED HYDROACOUSTIC BLOCKAGE ASSESSMENT AND DEVELOPMENT OF AN EXPLOSIVE SOURCE DATABASE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matzel, E; Ramirez, A; Harben, P
2005-07-11
We are continuing the development of the Hydroacoustic Blockage Assessment Tool (HABAT) which is designed for use by analysts to predict which hydroacoustic monitoring stations can be used in discrimination analysis for any particular event. The research involves two approaches (1) model-based assessment of blockage, and (2) ground-truth data-based assessment of blockage. The tool presents the analyst with a map of the world, and plots raypath blockages from stations to sources. The analyst inputs source locations and blockage criteria, and the tool returns a list of blockage status from all source locations to all hydroacoustic stations. We are currently usingmore » the tool in an assessment of blockage criteria for simple direct-path arrivals. Hydroacoustic data, predominantly from earthquake sources, are read in and assessed for blockage at all available stations. Several measures are taken. First, can the event be observed at a station above background noise? Second, can we establish backazimuth from the station to the source. Third, how large is the decibel drop at one station relative to other stations. These observational results are then compared with model estimates to identify the best set of blockage criteria and used to create a set of blockage maps for each station. The model-based estimates are currently limited by the coarse bathymetry of existing databases and by the limitations inherent in the raytrace method. In collaboration with BBN Inc., the Hydroacoustic Coverage Assessment Model (HydroCAM) that generates the blockage files that serve as input to HABAT, is being extended to include high-resolution bathymetry databases in key areas that increase model-based blockage assessment reliability. An important aspect of this capability is to eventually include reflected T-phases where they reliably occur and to identify the associated reflectors. To assess how well any given hydroacoustic discriminant works in separating earthquake and in-water explosion populations it is necessary to have both a database of reference earthquake events and of reference in-water explosive events. Although reference earthquake events are readily available, explosive reference events are not. Consequently, building an in-water explosion reference database requires the compilation of events from many sources spanning a long period of time. We have developed a database of small implosive and explosive reference events from the 2003 Indian Ocean Cruise data. These events were recorded at some or all of the IMS Indian Ocean hydroacoustic stations: Diego Garcia, Cape Leeuwin, and Crozet Island. We have also reviewed many historical large in-water explosions and identified five that have adequate source information and can be positively associated to the hydrophone recordings. The five events are: Cannekin, Longshot, CHASE-3, CHASE-5, and IITRI-1. Of these, the first two are nuclear tests on land but near water. The latter three are in-water conventional explosive events with yields from ten to hundreds of tons TNT equivalent. The objective of this research is to enhance discrimination capabilities for events located in the world's oceans. Two research and development efforts are needed to achieve this: (1) improvement in discrimination algorithms and their joint statistical application to events, and (2) development of an automated and accurate blockage prediction capability that will identify all stations and phases (direct and reflected) from a given event that will have adequate signal to be used in a discrimination analysis. The strategy for improving blockage prediction in the world's oceans is to improve model-based prediction of blockage and to develop a ground-truth database of reference events to assess blockage. Currently, research is focused on the development of a blockage assessment software tool. The tool is envisioned to develop into a sophisticated and unifying package that optimally and automatically assesses both model and data based blockage predictions in all ocean basins, for all NDC stations, and accounting for reflected phases (Pulli et al., 2000). Currently, we have focused our efforts on the Diego Garcia, Cape Leeuwin and Crozet Island hydroacoustic stations in the Indian Ocean.« less
Enhanced Positioning Algorithm of ARPS for Improving Accuracy and Expanding Service Coverage
Lee, Kyuman; Baek, Hoki; Lim, Jaesung
2016-01-01
The airborne relay-based positioning system (ARPS), which employs the relaying of navigation signals, was proposed as an alternative positioning system. However, the ARPS has limitations, such as relatively large vertical error and service restrictions, because firstly, the user position is estimated based on airborne relays that are located in one direction, and secondly, the positioning is processed using only relayed navigation signals. In this paper, we propose an enhanced positioning algorithm to improve the performance of the ARPS. The main idea of the enhanced algorithm is the adaptable use of either virtual or direct measurements of reference stations in the calculation process based on the structural features of the ARPS. Unlike the existing two-step algorithm for airborne relay and user positioning, the enhanced algorithm is divided into two cases based on whether the required number of navigation signals for user positioning is met. In the first case, where the number of signals is greater than four, the user first estimates the positions of the airborne relays and its own initial position. Then, the user position is re-estimated by integrating a virtual measurement of a reference station that is calculated using the initial estimated user position and known reference positions. To prevent performance degradation, the re-estimation is performed after determining its requirement through comparing the expected position errors. If the navigation signals are insufficient, such as when the user is outside of airborne relay coverage, the user position is estimated by additionally using direct signal measurements of the reference stations in place of absent relayed signals. The simulation results demonstrate that a higher accuracy level can be achieved because the user position is estimated based on the measurements of airborne relays and a ground station. Furthermore, the service coverage is expanded by using direct measurements of reference stations for user positioning. PMID:27529252
Enhanced Positioning Algorithm of ARPS for Improving Accuracy and Expanding Service Coverage.
Lee, Kyuman; Baek, Hoki; Lim, Jaesung
2016-08-12
The airborne relay-based positioning system (ARPS), which employs the relaying of navigation signals, was proposed as an alternative positioning system. However, the ARPS has limitations, such as relatively large vertical error and service restrictions, because firstly, the user position is estimated based on airborne relays that are located in one direction, and secondly, the positioning is processed using only relayed navigation signals. In this paper, we propose an enhanced positioning algorithm to improve the performance of the ARPS. The main idea of the enhanced algorithm is the adaptable use of either virtual or direct measurements of reference stations in the calculation process based on the structural features of the ARPS. Unlike the existing two-step algorithm for airborne relay and user positioning, the enhanced algorithm is divided into two cases based on whether the required number of navigation signals for user positioning is met. In the first case, where the number of signals is greater than four, the user first estimates the positions of the airborne relays and its own initial position. Then, the user position is re-estimated by integrating a virtual measurement of a reference station that is calculated using the initial estimated user position and known reference positions. To prevent performance degradation, the re-estimation is performed after determining its requirement through comparing the expected position errors. If the navigation signals are insufficient, such as when the user is outside of airborne relay coverage, the user position is estimated by additionally using direct signal measurements of the reference stations in place of absent relayed signals. The simulation results demonstrate that a higher accuracy level can be achieved because the user position is estimated based on the measurements of airborne relays and a ground station. Furthermore, the service coverage is expanded by using direct measurements of reference stations for user positioning.
Airborne relay-based regional positioning system.
Lee, Kyuman; Noh, Hongjun; Lim, Jaesung
2015-05-28
Ground-based pseudolite systems have some limitations, such as low vertical accuracy, multipath effects and near-far problems. These problems are not significant in airborne-based pseudolite systems. However, the monitoring of pseudolite positions is required because of the mobility of the platforms on which the pseudolites are mounted, and this causes performance degradation. To address these pseudolite system limitations, we propose an airborne relay-based regional positioning system that consists of a master station, reference stations, airborne relays and a user. In the proposed system, navigation signals are generated from the reference stations located on the ground and are relayed via the airborne relays. Unlike in conventional airborne-based systems, the user in the proposed system sequentially estimates both the locations of airborne relays and his/her own position. Therefore, a delay due to monitoring does not occur, and the accuracy is not affected by the movement of airborne relays. We conducted several simulations to evaluate the performance of the proposed system. Based on the simulation results, we demonstrated that the proposed system guarantees a higher accuracy than airborne-based pseudolite systems, and it is feasible despite the existence of clock offsets among reference stations.
Airborne Relay-Based Regional Positioning System
Lee, Kyuman; Noh, Hongjun; Lim, Jaesung
2015-01-01
Ground-based pseudolite systems have some limitations, such as low vertical accuracy, multipath effects and near-far problems. These problems are not significant in airborne-based pseudolite systems. However, the monitoring of pseudolite positions is required because of the mobility of the platforms on which the pseudolites are mounted, and this causes performance degradation. To address these pseudolite system limitations, we propose an airborne relay-based regional positioning system that consists of a master station, reference stations, airborne relays and a user. In the proposed system, navigation signals are generated from the reference stations located on the ground and are relayed via the airborne relays. Unlike in conventional airborne-based systems, the user in the proposed system sequentially estimates both the locations of airborne relays and his/her own position. Therefore, a delay due to monitoring does not occur, and the accuracy is not affected by the movement of airborne relays. We conducted several simulations to evaluate the performance of the proposed system. Based on the simulation results, we demonstrated that the proposed system guarantees a higher accuracy than airborne-based pseudolite systems, and it is feasible despite the existence of clock offsets among reference stations. PMID:26029953
Chen, James L; Bahna, Sami L
2011-09-01
To provide a review on spice allergy and its implementation in clinical practice. PubMed searches were performed using spice allergy as the keyword for original and review articles. Selected references were also procured from the reviewed articles' references list. Articles were selected based on their relevance to the topic. Spices are available in a large variety and are widely used, often as blends. Spice allergy seems to be rare, reportedly affecting between 4 and 13 of 10,000 adults and occurring more often in women because of cosmetic use. No figures were available on children. Most spice allergens are degraded by digestion; therefore, IgE sensitization is mostly through inhalation of cross-reacting pollens, particularly mugwort and birch. The symptoms are more likely to be respiratory when exposure is by inhalation and cutaneous if by contact. Studies on skin testing and specific IgE assays are limited and showed low reliability. The diagnosis primarily depends on a good history taking and confirmation with oral challenge. The common use of spice blends makes identifying the particular offending component difficult, particularly because their components are inconsistent. Spices are widely used and contain multiple allergens, yet spice allergy is probably markedly underdiagnosed. There is a need for reliable skin testing extracts and serum specific IgE assays. Currently, the diagnosis depends on a good history taking and well-designed titrated challenge testing. Until immunotherapy becomes developed, treatment is strict avoidance, which may be difficult because of incomplete or vague labeling. Copyright © 2011 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Soares, Janer Aparecida Silveira; Carvalho, Sílvio Fernando Guimarães; Caldeira, Antônio Prates
2012-02-01
To describe the clinical and epidemiological profile of pregnant women and children treated at a reference outpatient clinic for congenital toxoplasmosis. Pregnant women potentially exposed to Toxoplasma gondii were observed. Diagnoses were made using serologic tests compatible with acute toxoplasmosis. Children presenting with: Toxoplasma-specific antibodies (IgM or IgA or ascending IgG titers higher than maternal titers in the first 3 months of life) coupled with toxoplasmosis symptoms; intracranial calcifications (by transfontanelar ultrasound or cephalic segment tomography); or retinochoroiditis (by fundoscopy examination) in the first 8 months of life were also included in the study. Fifty-eight mother-child pairs were observed (mean age of the mothers was 22.1 years). Most patients lived in urban areas (86.2%) and had attended less than 8 years of school (51.7%). Diagnosis was made after birth in 19 (32.8%) children. Thirty-four (58.6%) women received some type of treatment during pregnancy. Most (72.4%) of the children did not present with clinical alterations at birth. The main findings were ophthalmological: 20 (34.5%) children with retinochoroiditis, 17 (29.3%) with strabismus, and 7 (12.1%) with nystagmus. Of the children with retinochoroiditis, 9 presented with subnormal vision. Ten (32.3%) out of 31 children presented with intracranial calcifications by cephalic segment congenital toxoplasmosis, and 9 (42.9%) children presented with delayed psychomotor development. Our results highlight a critical situation. Protocols for follow-up of pregnant women and their children must be created to improve medical care and minimize sequelae.
Peng, Yanfen; Gelder, Victor Van; Amaladoss, Anburaj; Patel, Kadamb Haribhai
2016-10-21
This report presents two methods for the covalent immobilization of capture antibodies on cellulose filter paper grade No. 1 (medium-flow filter paper) discs and grade No. 113 (fast-flow filter paper) discs. These cellulose paper discs were grafted with amine functional groups through a silane coupling technique before the antibodies were immobilized on them. Periodate oxidation and glutaraldehyde cross-linking methods were used to graft capture antibodies on the cellulose paper discs. In order to ensure the maximum binding capacity of the capture antibodies to their targets after immobilization, the effects of various concentrations of sodium periodate, glutaraldehyde, and capture antibodies on the surface of the paper discs were investigated. The antibodies that were coated on the amine-functionalized cellulose paper discs through a glutaraldehyde cross-linking agent showed enhanced binding activity to the target when compared to the periodate oxidation method. IgG (in mouse reference serum) was used as a reference target in this study to test the application of covalently immobilized antibodies through glutaraldehyde. A new paper-based, enzyme-linked immunosorbent assay (ELISA) was successfully developed and validated for the detection of IgG. This method does not require equipment, and it can detect 100 ng/ml of IgG. The fast-flow filter paper was more sensitive than the medium-flow filter paper. The incubation period of this assay was short and required small sample volumes. This naked-eye, colorimetric immunoassay can be extended to detect other targets that are identified with conventional ELISA.
NASA Astrophysics Data System (ADS)
Appleby, Graham; Rodríguez, José; Altamimi, Zuheir
2016-12-01
Satellite laser ranging (SLR) to the geodetic satellites LAGEOS and LAGEOS-2 uniquely determines the origin of the terrestrial reference frame and, jointly with very long baseline interferometry, its scale. Given such a fundamental role in satellite geodesy, it is crucial that any systematic errors in either technique are at an absolute minimum as efforts continue to realise the reference frame at millimetre levels of accuracy to meet the present and future science requirements. Here, we examine the intrinsic accuracy of SLR measurements made by tracking stations of the International Laser Ranging Service using normal point observations of the two LAGEOS satellites in the period 1993 to 2014. The approach we investigate in this paper is to compute weekly reference frame solutions solving for satellite initial state vectors, station coordinates and daily Earth orientation parameters, estimating along with these weekly average range errors for each and every one of the observing stations. Potential issues in any of the large number of SLR stations assumed to have been free of error in previous realisations of the ITRF may have been absorbed in the reference frame, primarily in station height. Likewise, systematic range errors estimated against a fixed frame that may itself suffer from accuracy issues will absorb network-wide problems into station-specific results. Our results suggest that in the past two decades, the scale of the ITRF derived from the SLR technique has been close to 0.7 ppb too small, due to systematic errors either or both in the range measurements and their treatment. We discuss these results in the context of preparations for ITRF2014 and additionally consider the impact of this work on the currently adopted value of the geocentric gravitational constant, GM.
Reduction of ZTD outliers through improved GNSS data processing and screening strategies
NASA Astrophysics Data System (ADS)
Stepniak, Katarzyna; Bock, Olivier; Wielgosz, Pawel
2018-03-01
Though Global Navigation Satellite System (GNSS) data processing has been significantly improved over the years, it is still commonly observed that zenith tropospheric delay (ZTD) estimates contain many outliers which are detrimental to meteorological and climatological applications. In this paper, we show that ZTD outliers in double-difference processing are mostly caused by sub-daily data gaps at reference stations, which cause disconnections of clusters of stations from the reference network and common mode biases due to the strong correlation between stations in short baselines. They can reach a few centimetres in ZTD and usually coincide with a jump in formal errors. The magnitude and sign of these biases are impossible to predict because they depend on different errors in the observations and on the geometry of the baselines. We elaborate and test a new baseline strategy which solves this problem and significantly reduces the number of outliers compared to the standard strategy commonly used for positioning (e.g. determination of national reference frame) in which the pre-defined network is composed of a skeleton of reference stations to which secondary stations are connected in a star-like structure. The new strategy is also shown to perform better than the widely used strategy maximizing the number of observations available in many GNSS programs. The reason is that observations are maximized before processing, whereas the final number of used observations can be dramatically lower because of data rejection (screening) during the processing. The study relies on the analysis of 1 year of GPS (Global Positioning System) data from a regional network of 136 GNSS stations processed using Bernese GNSS Software v.5.2. A post-processing screening procedure is also proposed to detect and remove a few outliers which may still remain due to short data gaps. It is based on a combination of range checks and outlier checks of ZTD and formal errors. The accuracy of the final screened GPS ZTD estimates is assessed by comparison to ERA-Interim reanalysis.
47 CFR 73.1209 - References to time.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 4 2010-10-01 2010-10-01 false References to time. 73.1209 Section 73.1209 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO BROADCAST SERVICES Rules Applicable to All Broadcast Stations § 73.1209 References to time. Unless specifically designated...
Is There a Relationship between Zinc and the Peculiar Comorbidities of Down Syndrome?
ERIC Educational Resources Information Center
Romano, Corrado; Pettinato, Rosa; Ragusa, Letizia; Barone, Concetta; Alberti, Antonino; Failla, Pinella
2002-01-01
A comparison was made between a range of clinical and biochemical variables and zinc levels in 120 individuals with Down syndrome. No significant differences were found between the normal-zinc and low-zinc groups, except for IgG4 which was, unexpectedly, significantly decreased in the group with normal zinc levels. (Contains references.)…
NASA Astrophysics Data System (ADS)
Kisi, Ozgur; Kilic, Yasin
2016-11-01
The generalization ability of artificial neural networks (ANNs) and M5 model tree (M5Tree) in modeling reference evapotranspiration ( ET 0 ) is investigated in this study. Daily climatic data, average temperature, solar radiation, wind speed, and relative humidity from six different stations operated by California Irrigation Management Information System (CIMIS) located in two different regions of the USA were used in the applications. King-City Oasis Rd., Arroyo Seco, and Salinas North stations are located in San Joaquin region, and San Luis Obispo, Santa Monica, and Santa Barbara stations are located in the Southern region. In the first part of the study, the ANN and M5Tree models were used for estimating ET 0 of six stations and results were compared with the empirical methods. The ANN and M5Tree models were found to be better than the empirical models. In the second part of the study, the ANN and M5Tree models obtained from one station were tested using the data from the other two stations for each region. ANN models performed better than the CIMIS Penman, Hargreaves, Ritchie, and Turc models in two stations while the M5Tree models generally showed better accuracy than the corresponding empirical models in all stations. In the third part of the study, the ANN and M5Tree models were calibrated using three stations located in San Joaquin region and tested using the data from the other three stations located in the Southern region. Four-input ANN and M5Tree models performed better than the CIMIS Penman in only one station while the two-input ANN models were found to be better than the Hargreaves, Ritchie, and Turc models in two stations.
NASA Astrophysics Data System (ADS)
Hurtado-Cardador, Manuel; Urrutia-Fucugauchi, Jaime
2006-12-01
Since 1947 Petroleos Mexicanos (Pemex) has conducted oil exploration projects using potential field methods. Geophysical exploration companies under contracts with Pemex carried out gravity anomaly surveys that were referred to different floating data. Each survey comprises observations of gravity stations along highways, roads and trails at intervals of about 500 m. At present, 265 separate gravimeter surveys that cover 60% of the Mexican territory (mainly in the oil producing regions of Mexico) are available. This gravity database represents the largest, highest spatial resolution information, and consequently has been used in the geophysical data compilations for the Mexico and North America gravity anomaly maps. Regional integration of gravimeter surveys generates gradients and spurious anomalies in the Bouguer anomaly maps at the boundaries of the connected surveys due to the different gravity base stations utilized. The main objective of this study is to refer all gravimeter surveys from Pemex to a single new first-order gravity base station network, in order to eliminate problems of gradients and spurious anomalies. A second objective is to establish a network of permanent gravity base stations (BGP), referred to a single base from the World Gravity System. Four regional loops of BGP covering eight States of Mexico were established to support the tie of local gravity base stations from each of the gravimeter surveys located in the vicinity of these loops. The third objective is to add the gravity constants, measured and calculated, for each of the 265 gravimeter surveys to their corresponding files in the Pemex and Instituto Mexicano del Petroleo database. The gravity base used as the common datum is the station SILAG 9135-49 (Latin American System of Gravity) located in the National Observatory of Tacubaya in Mexico City. We present the results of the installation of a new gravity base network in northeastern Mexico, reference of the 43 gravimeter surveys to the new network, the regional compilation of Bouguer gravity data and a new updated Bouguer gravity anomaly map for northeastern Mexico.
Particulate Matter Exposure in a Police Station Located near a Highway.
Chen, Yu-Cheng; Hsu, Chin-Kai; Wang, Chia C; Tsai, Perng-Jy; Wang, Chun-Yuan; Chen, Mei-Ru; Lin, Ming-Yeng
2015-11-13
People living or working near roadways have experienced an increase in cardiovascular or respiratory diseases due to vehicle emissions. Very few studies have focused on the PM exposure of highway police officers, particularly for the number concentration and size distribution of ultrafine particles (UFP). This study evaluated exposure concentrations of particulate matter (PM) in the Sinying police station near a highway located in Tainan, Taiwan, under different traffic volumes, traffic types, and shift times. We focused on periods when the wind blew from the highway toward the police station and when the wind speed was greater than or equal to 0.5 m/s. PM2.5, UFP, and PM-PAHs concentrations in the police station and an upwind reference station were measured. Results indicate that PM2.5, UFP, and PM-PAHs concentrations in the police station can be on average 1.13, 2.17, and 5.81 times more than the upwind reference station concentrations, respectively. The highest exposure level for PM2.5 and UFP was observed during the 12:00 PM-4:00 PM shift while the highest PAHs concentration was found in the 4:00 AM-8:00 AM shift. Thus, special attention needs to be given to protect police officers from exposure to high PM concentration.
Particulate Matter Exposure in a Police Station Located near a Highway
Chen, Yu-Cheng; Hsu, Chin-Kai; Wang, Chia C.; Tsai, Perng-Jy; Wang, Chun-Yuan; Chen, Mei-Ru; Lin, Ming-Yeng
2015-01-01
People living or working near roadways have experienced an increase in cardiovascular or respiratory diseases due to vehicle emissions. Very few studies have focused on the PM exposure of highway police officers, particularly for the number concentration and size distribution of ultrafine particles (UFP). This study evaluated exposure concentrations of particulate matter (PM) in the Sinying police station near a highway located in Tainan, Taiwan, under different traffic volumes, traffic types, and shift times. We focused on periods when the wind blew from the highway toward the police station and when the wind speed was greater than or equal to 0.5 m/s. PM2.5, UFP, and PM-PAHs concentrations in the police station and an upwind reference station were measured. Results indicate that PM2.5, UFP, and PM-PAHs concentrations in the police station can be on average 1.13, 2.17, and 5.81 times more than the upwind reference station concentrations, respectively. The highest exposure level for PM2.5 and UFP was observed during the 12:00 PM–4:00 PM shift while the highest PAHs concentration was found in the 4:00 AM–8:00 AM shift. Thus, special attention needs to be given to protect police officers from exposure to high PM concentration. PMID:26580641
Tesmoingt, Chloe; Lidove, Olivier; Reberga, Axele; Thetis, Marguerite; Ackaert, Chloe; Nicaise, Pascale; Arnaud, Philippe; Papo, Thomas
2009-11-01
To report a severe adverse event related to enzyme replacement therapy with agalsidase in an hemizygous male patient treated for Fabry disease. Retrospective analysis of clinical, radiological and biochemical data in a patient who suffered adverse events related to both agalsidase alfa and agalsidase beta treatments. A hemizygous male patient was first treated for Fabry disease with agalsidase alfa. After more than 1 year of therapy, infusion-related symptoms necessitated systemic steroids and antihistaminic therapy. Decline in kidney function prompted a switch for agalsidase beta. Anaphylactoid shock occurred after the second infusion. No serum IgE antibodies were disclosed. Skin-test reactivity to agalsidase beta was negative. Following a published rechallenge infusion protocol, agalsidase beta was reintroduced, leading to a second anaphylactoid shock episode. Enzyme replacement therapy was stopped and the patient was treated with symptomatic therapy only. This case was referred to the pharmacovigilance department. The negativity of immunological tests (specific anti-agalsidase IgE antibodies and skin tests) does not rule out the risk of repeated anaphylactoid shock following agalsidase infusion.
Tesmoingt, Chloe; Lidove, Olivier; Reberga, Axele; Thetis, Marguerite; Ackaert, Chloe; Nicaise, Pascale; Arnaud, Philippe; Papo, Thomas
2009-01-01
AIMS To report a severe adverse event related to enzyme replacement therapy with agalsidase in an hemizygous male patient treated for Fabry disease. METHODS Retrospective analysis of clinical, radiological and biochemical data in a patient who suffered adverse events related to both agalsidase alfa and agalsidase beta treatments. RESULTS A hemizygous male patient was first treated for Fabry disease with agalsidase alfa. After more than 1 year of therapy, infusion-related symptoms necessitated systemic steroids and antihistaminic therapy. Decline in kidney function prompted a switch for agalsidase beta. Anaphylactoid shock occurred after the second infusion. No serum IgE antibodies were disclosed. Skin-test reactivity to agalsidase beta was negative. Following a published rechallenge infusion protocol, agalsidase beta was reintroduced, leading to a second anaphylactoid shock episode. Enzyme replacement therapy was stopped and the patient was treated with symptomatic therapy only. This case was referred to the pharmacovigilance department. CONCLUSION The negativity of immunological tests (specific anti-agalsidase IgE antibodies and skin tests) does not rule out the risk of repeated anaphylactoid shock following agalsidase infusion. PMID:19917001
Sharp, Tyler M.; Lalita, Paul; Tikomaidraubuta, Kini; Cardoso, Yolanda Rebello; Naivalu, Taina; Khan, Aalisha Sahu; Marfel, Maria; Hancock, W. Thane; Tomashek, Kay M.; Margolis, Harold S.
2016-01-01
Dengue is major public health problem, globally. Timely verification of suspected dengue outbreaks allows for public health response, leading to the initiation of appropriate clinical care. Because the clinical presentation of dengue is nonspecific, dengue diagnosis would benefit from a sensitive rapid diagnostic test (RDT). We evaluated the diagnostic performance of an RDT that detects dengue virus (DENV) nonstructural protein 1 (NS1) and anti-DENV IgM during suspected acute febrile illness (AFI) outbreaks in four countries. Real-time reverse transcription-PCR and anti-DENV IgM enzyme-linked immunosorbent assay were used to verify RDT results. Anti-DENV IgM RDT sensitivity and specificity ranged from 55.3 to 91.7% and 85.3 to 98.5%, respectively, and NS1 sensitivity and specificity ranged from 49.7 to 92.9% and 22.2 to 89.0%, respectively. Sensitivity varied by timing of specimen collection and DENV serotype. Combined test results moderately improved the sensitivity. The use of RDTs identified dengue as the cause of AFI outbreaks where reference diagnostic testing was limited or unavailable. PMID:27225409
Clinical and immunological investigations of respiratory disease in workers using reactive dyes.
Docker, A; Wattie, J M; Topping, M D; Luczynska, C M; Newman Taylor, A J; Pickering, C A; Thomas, P; Gompertz, D
1987-01-01
A questionnaire survey of over 400 workers handling reactive dyes showed that over 15% had work related respiratory or nasal symptoms. Forty nine employees with symptoms were referred to chest clinics for detailed assessment. It was considered that in 19 the symptoms could be attributed to an irritant response to a variety of chemicals, including hydrochloric acid vapour, sulphur dioxide, and reactive dyes. Symptoms in 24 were attributed to an allergic reaction to a specific agent; in most (21) to one or more reactive dyes. Two patterns of allergic lower respiratory symptoms were identified; an immediate response of short duration and a longer lasting response, usually of several hours, sometimes accompanied by nocturnal asthma. A radioallergosorbent test (RAST) screen containing the most commonly used reactive dyes was used to detect specific IgE. Allergic symptoms to reactive dyes were strongly associated with specific IgE (17/21 employees) and atopy (18/21). Irritant symptoms were also associated with atopy (13/19) but only weakly associated with specific IgE (7/19). PMID:3651352
Multi-geodetic characterization of the seasonal signal at the CERGA geodetic reference, France
NASA Astrophysics Data System (ADS)
Memin, A.; Viswanathan, V.; Fienga, A.; Santamaría-Gómez, A.; Boy, J. P.
2016-12-01
Crustal deformations due to surface-mass loading account for a significant part of the variability in geodetic time series. A perfect understanding of the loading signal observed by geodetic techniques should help in improving terrestrial reference frame (TRF) realizations. Yet, discrepancies between crustal motion estimates from models of surface-mass loading and observations are still too large so that no model is currently recommended by the IERS for reducing the data. We investigate the discrepancy observed in the seasonal variations of the CERGA station, South of France.We characterize the seasonal motions of the reference geodetic station CERGA from GNSS, SLR and LLR. We compare the station motion observed with GNSS and SLR and we estimate changes in the station-to-the-moon distance using an improved processing strategy. We investigate the consistency between these geodetic techniques and compare the observed station motion with that estimated using models of surface-mass change. In that regard, we compute atmospheric loading effects using surface pressure fields from ECMWF, assuming an ocean response according to the classical inverted barometer (IB) assumption, considered to be valid for periods typically exceeding a week. We also used general circulation ocean models (ECCO and GLORYS) forced by wind, heat and fresh water fluxes. The continental water storage is described using GLDAS/Noah and MERRA-land models.Using the surface-mass models, we estimate the amplitude of the seasonal vertical motion of the CERGA station ranging between 5 and 10 mm with a maximum reached in August, mostly due to hydrology. The horizontal seasonal motion of the station may reach up to 3 mm. Such a station motion should induce a change in the distance to the moon reaching up to 10 mm, large enough to be detected in LLR time series and compared to GNSS- and SLR-derived motion.
Designing an Ergonomically Correct CNC Workstation on a Shoe String Budget.
ERIC Educational Resources Information Center
Lightner, Stan
2001-01-01
Describes research to design and construct ergonomically correct work stations for Computer Numerical Control machine tools. By designing ergonomically correct work stations, industrial technology teachers help protect students from repetitive motion injuries. (Contains 12 references.) (JOW)
Study of the GPS inter-frequency calibration of timing receivers
NASA Astrophysics Data System (ADS)
Defraigne, P.; Huang, W.; Bertrand, B.; Rovera, D.
2018-02-01
When calibrating Global Positioning System (GPS) stations dedicated to timing, the hardware delays of P1 and P2, the P(Y)-codes on frequencies L1 and L2, are determined separately. In the international atomic time (TAI) network the GPS stations of the time laboratories are calibrated relatively against reference stations. This paper aims at determining the consistency between the P1 and P2 hardware delays (called dP1 and dP2) of these reference stations, and to look at the stability of the inter-signal hardware delays dP1-dP2 of all the stations in the network. The method consists of determining the dP1-dP2 directly from the GPS pseudorange measurements corrected for the frequency-dependent antenna phase center and the frequency-dependent ionosphere corrections, and then to compare these computed dP1-dP2 to the calibrated values. Our results show that the differences between the computed and calibrated dP1-dP2 are well inside the expected combined uncertainty of the two quantities. Furthermore, the consistency between the calibrated time transfer solution obtained from either single-frequency P1 or dual-frequency P3 for reference laboratories is shown to be about 1.0 ns, well inside the 2.1 ns uB uncertainty of a time transfer link based on GPS P3 or Precise Point Positioning. This demonstrates the good consistency between the P1 and P2 hardware delays of the reference stations used for calibration in the TAI network. The long-term stability of the inter-signal hardware delays is also analysed from the computed dP1-dP2. It is shown that only variations larger than 2 ns can be detected for a particular station, while variations of 200 ps can be detected when differentiating the results between two stations. Finally, we also show that in the differential calibration process as used in the TAI network, using the same antenna phase center or using different positions for L1 and L2 signals gives maximum differences of 200 ps on the hardware delays of the separate codes P1 and P2; however, the final impact on the P3 combination is less than 10 ps.
An Enhanced Box-Wing Solar Radiation pressure model for BDS and initial results
NASA Astrophysics Data System (ADS)
Zhao, Qunhe; Wang, Xiaoya; Hu, Xiaogong; Guo, Rui; Shang, Lin; Tang, Chengpan; Shao, Fan
2016-04-01
Solar radiation pressure forces are the largest non-gravitational perturbations acting on GNSS satellites, which is difficult to be accurately modeled due to the complicated and changing satellite attitude and unknown surface material characteristics. By the end of 2015, there are more than 50 stations of the Multi-GNSS Experiment(MGEX) set-up by the IGS. The simple box-plate model relies on coarse assumptions about the dimensions and optical properties of the satellite due to lack of more detailed information. So, a physical model based on BOX-WING model is developed, which is more sophisticated and more detailed physical structure has been taken into account, then calculating pressure forces according to the geometric relations between light rays and surfaces. All the MGEX stations and IGS core stations had been processed for precise orbit determination tests with GPS and BDS observations. Calculation range covers all the two kinds of Eclipsing and non-eclipsing periods in 2015, and we adopted the un-differential observation mode and more accurate values of satellite phase centers. At first, we tried nine parameters model, and then eliminated the parameters with strong correlation between them, came into being five parameters of the model. Five parameters were estimated, such as solar scale, y-bias, three material coefficients of solar panel, x-axis and z-axis panels. Initial results showed that, in the period of yaw-steering mode, use of Enhanced ADBOXW model results in small improvement for IGSO and MEO satellites, and the Root-Mean-Square(RMS) error value of one-day arc orbit decreased by about 10%~30% except for C08 and C14. The new model mainly improved the along track acceleration, up to 30% while in the radial track was not obvious. The Satellite Laser Ranging(SLR) validation showed, however, that this model had higher prediction accuracy in the period of orbit-normal mode, compared to GFZ multi-GNSS orbit products, as well with relative post-processing results. Because of the system bias and unknown reasons, GEO satellites had bad results, when after adding some Chinese regional stations, there had an obviously improvement of the orbit precision. This model can be used as a priori model to help build experience models for the later works.
NASA Astrophysics Data System (ADS)
Kubicki, Marek; Konarski, Jerzy; Gajda, Wojciech; Barański, Piotr; Guzikowski, Jakub; Kryza, Maciej
2017-04-01
In this work we present preliminary results on the thunderstorm event at IG PAS Swider Geophysical Observatory (52.12°N, 21.25°E, geomagnetic latitude 50.5°N, near Warsaw, Poland) on 19 July 2015. The storm was caused by the abrasion of the warm front that stretched almost latitudinaly and cold front moving from the west to the east. Warm continental-tropical arrived at southern and eastern part of the country and the rest was covered by cool polar-maritime airmass. The storm had the squall-line character of approximately 100 km length and consisted of several cells, and the height of the cumulonimbus (Cb) cloud base was 1 km and top was 14 km, as inferred from the analysis of CAPPI (Constant Altitude Plan Position Indicator), CMAX (Column Maximum Display), MLVCUT (Multiple-Line Vertical Cut) radar map products from POLRAD observations at Institute of Meteorology and Water Management - National Research Institute (IMWM-NRI), Legionowo station. In our paper we have discussed the obtained results of the post-time analysis of lightning activity and radar observations of the extended multicells thunderstorm system passing over IG PAS Swider Geophysical Observatory, on 19 July 2015 together with its dynamic and electric charge structure obtained from the WRF_ELEC model. We have used the archive data from the Polish National Lightning Location and Detection System PERUN (provided by IMWM-NRI) together with radar data obtained from the Doppler meteorological radar METEOR 1500C at Legionowo. Additionally, during the approach, passing over and moving away phase of the thunderstorm system, we have gathered the simultaneous and continuous recordings of E-field, the electric conductivity of air and the independent supplementary reference lightning detections delivered by the Swider measuring station of the Local Lightning Detection Network (LLDN) operated in Warsaw region. These data have given us a new possibility to acquire many valuable information about the characteristic type of the particular lightning flashes that were initiated by different adjacent thunderstorm cells developed in this time. On the other hand, the recorded E-field signatures of the lightning strokes by the LLDN measuring station have enabled us to differentiate between the variety of their types indicating the complex electric charge structure of the particular thunderstorm cells which developed in this storm system. Moreover, on the base of the supplementary numerical simulations of the considered thunderstorm episode by applying the WRF_ELEC model to the post-time analysis we were able to obtain the more detailed picture with more thermodynamic parameters not only about the specific electric charge structure of the considered thunderstorm cells, and how their thermodynamic pattern created the suitable conditions to initiate the observed lightning stroke types. Atmospheric electricity observations at Swider have been supported within the statutory activities of Institute of Geophysics, PAS, grant No. 3841/E-41/S/2016 and 3841/E-41/S/2017 of the Ministry of Science and Higher Education of Poland.
Jason-2 systematic error analysis in the GPS derived orbits
NASA Astrophysics Data System (ADS)
Melachroinos, S.; Lemoine, F. G.; Zelensky, N. P.; Rowlands, D. D.; Luthcke, S. B.; Chinn, D. S.
2011-12-01
Several results related to global or regional sea level changes still too often rely on the assumption that orbit errors coming from station coordinates adoption can be neglected in the total error budget (Ceri et al. 2010). In particular Instantaneous crust-fixed coordinates are obtained by adding to the linear ITRF model the geophysical high-frequency variations. In principle, geocenter motion should also be included in this computation, in order to reference these coordinates to the center of mass of the whole Earth. This correction is currently not applied when computing GDR orbits. Cerri et al. (2010) performed an analysis of systematic errors common to all coordinates along the North/South direction, as this type of bias, also known as Z-shift, has a clear impact on MSL estimates due to the unequal distribution of continental surface in the northern and southern hemispheres. The goal of this paper is to specifically study the main source of errors which comes from the current imprecision in the Z-axis realization of the frame. We focus here on the time variability of this Z-shift, which we can decompose in a drift and a periodic component due to the presumably omitted geocenter motion. A series of Jason-2 GPS-only orbits have been computed at NASA GSFC, using both IGS05 and IGS08. These orbits have been shown to agree radially at less than 1 cm RMS vs our SLR/DORIS std0905 and std1007 reduced-dynamic orbits and in comparison with orbits produced by other analysis centers (Melachroinos et al. 2011). Our GPS-only JASON-2 orbit accuracy is assessed using a number of tests including analysis of independent SLR and altimeter crossover residuals, orbit overlap differences, and direct comparison to orbits generated at GSFC using SLR and DORIS tracking, and to orbits generated externally at other centers. Tests based on SLR-crossover residuals provide the best performance indicator for independent validation of the NASA/GSFC GPS-only reduced dynamic orbits. Reduced dynamic versus dynamic orbit differences are used to characterize the remaining force model error and TRF instability. At first, we quantify the effect of a North/South displacement of the tracking reference points for each of the three techniques. We then compare these results to the study of Morel and Willis (2005) and Ceri et al. (2010). We extend the analysis to the most recent Jason-2 cycles. We evaluate the GPS vs SLR & DORIS orbits produced using the GEODYN.
Blanchard, Myra T; Anderson, Mark L; Hoar, Bruce R; Pires, Alda F A; Blanchard, Patricia C; Yeargan, Bret V; Teglas, Mike B; Belshaw, Margaret; Stott, Jeffery L
2014-09-01
The current study was directed at developing and validating an indirect fluorescent antibody test (IFAT) capable of detecting antibodies specific for the agent of epizootic bovine abortion (aoEBA). Sensitivity and specificity was determined by comparing antibody titers from 114 fetuses infected with aoEBA with 68 fetuses diagnosed with alternate infectious etiologies. Data established specificity at 100% and sensitivity at 94.7% when cutoff criteria for a positive test were assigned at a titer of ≥1,000. Potential cross-reactivity was noted in samples from 3 fetuses with antibody titers of 10 or100; all were infected with Gram-positive organisms. The remaining 65 fetuses infected with microbes other than aoEBA, and an additional 12 negative reference sera, did not have detectable titers. The IFAT-based serology assay is rapid, reproducible, and unaffected by fluid color or opacity. Total fetal immunoglobulin (Ig)G was also evaluated as an aid for diagnosing EBA. Significantly higher concentrations of IgG were identified in fetuses infected with aoEBA as compared to those with alternate infectious etiologies. The presence of IgG is a sensitive indicator of EBA and increases the specificity of FAT-based serologic diagnosis when titers are 10 or 100. Taken together, serology and IgG analyses suggest that the incidence of EBA may be underestimated. © 2014 The Author(s).
Capobiango, Jaqueline Dario; Pagliari, Sthefany; Pasquali, Aline Kuhn Sbruzzi; Nino, Beatriz; Ferreira, Fernanda Pinto; Monica, Thaís Cabral; Tschurtschenthaler, Nely Norder; Navarro, Italmar Teodorico; Garcia, João Luis; Mitsuka-Breganó, Regina; Reiche, Edna Maria Vissoci
2015-09-01
The aim of this study was to evaluate an enzyme-linked immunoassay with recombinant rhoptry protein 2 (ELISA-rROP2) for its ability to detect Toxoplasma gondii ROP2-specific IgG in samples from pregnant women. The study included 236 samples that were divided into groups according to serological screening profiles for toxoplasmosis: unexposed (n = 65), probable acute infection (n = 48), possible acute infection (n = 58) and exposed to the parasite (n = 65). When an indirect immunofluorescence assay forT. gondii-specific IgG was considered as a reference test, the ELISA-rROP2 had a sensitivity of 61.8%, specificity of 62.8%, predictive positive value of 76.6% and predictive negative value of 45.4% (p = 0.0002). The ELISA-rROP2 reacted with 62.5% of the samples from pregnant women with probable acute infection and 40% of the samples from pregnant women with previous exposure (p = 0.0180). Seropositivity was observed in 50/57 (87.7%) pregnant women with possible infection. The results underscored that T. gondii rROP2 is recognised by specific IgG antibodies in both the acute and chronic phases of toxoplasmosis acquired during pregnancy. However, the sensitivity of the ELISA-rROP2 was higher in the pregnant women with probable and possible acute infections and IgM reactivity.
Davidsson, Pia; Söderling, Ann-Sofi; Svensson, Lena; Ahnmark, Andrea; Flodin, Christine; Wanag, Ewa; Screpanti-Sundqvist, Valentina; Gennemark, Peter
2015-05-01
Tissue distribution and pharmacokinetics (PK) of full-length nontargeted antibody and its antigen-binding fragment (FAb) were evaluated for a range of tissues primarily of interest for cardiovascular and metabolic diseases. Mice were intravenously injected with a dose of 10 mg/kg of either human IgG1or its FAb fragment; perfused tissues were collected at a range of time points over 3 weeks for the human IgG1 antibody and 1 week for the human FAb antibody. Tissues were homogenized and antibody concentrations were measured by specific immunoassays on the Gyros system. Exposure in terms of maximum concentration (Cmax ) and area under the curve was assessed for all nine tissues. Tissue exposure of full-length antibody relative to plasma exposure was found to be between 1% and 10%, except for brain (0.2%). Relative concentrations of FAb antibody were the same, except for kidney tissue, where the antibody concentration was found to be ten times higher than in plasma. However, the absolute tissue uptake of full-length IgG was significantly higher than the absolute tissue uptake of the FAb antibody. This study provides a reference PK state for full-length whole and FAb antibodies in tissues related to cardiovascular and metabolic diseases that do not include antigen or antibody binding. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.
Space station group activities habitability module study
NASA Technical Reports Server (NTRS)
Nixon, David
1986-01-01
This study explores and analyzes architectural design approaches for the interior of the Space Station Habitability Module (originally defined as Habitability Module 1 in Space Station Reference Configuration Decription, JSC-19989, August 1984). In the Research Phase, architectural program and habitability design guidelines are specified. In the Schematic Design Phase, a range of alternative concepts is described and illustrated with drawings, scale-model photographs and design analysis evaluations. Recommendations are presented on the internal architectural, configuration of the Space Station Habitability Module for such functions as the wardroom, galley, exercise facility, library and station control work station. The models show full design configurations for on-orbit performance.
Epicutaneous immunotherapy on intact skin using a new delivery system in a murine model of allergy.
Mondoulet, L; Dioszeghy, V; Ligouis, M; Dhelft, V; Dupont, C; Benhamou, P-H
2010-04-01
Allergen-specific immunotherapy, subcutaneous immunotherapy (SCIT) or oral, has been used for almost a century to redirect inappropriate immune responses in atopic patients. A new mode of administration through the intact skin [epicutaneous immunotherapy (EPIT)], using an original epicutaneous delivery system, may represent an alternative to these classical methods. Proof of concept of efficacy of EPIT on intact skin in mice sensitized to aeroallergens or food allergens. Mice were sensitized to pollen (n=18), house dust mite (HDM, n=24), ovalbumin (OVA, n=18) or peanut (n=18), and allocated to four groups: EPIT, SCIT, not treated (NT) and control. Specific Ig (sIg)E, sIgG1 and sIgG2a were monitored. After 8 weeks of treatment, plethysmography was performed after aerosol provocation with appropriate allergens. At the highest doses of methacholine, pause enhancement (Penh) values were significantly decreased in the EPIT group vs. the sensitized NT groups (7.5 vs. 12.3 - pollen, 7.6 vs. 8.9 - HDM, 11.5 vs. 14.5 - OVA, 7.6 vs. 12.8 - peanut, respectively) (P<0.05). With all the allergens tested, Penh values were similar in SCIT, EPIT and control. IgG2a for pollen, HDM, OVA and peanuts were significantly increased in the EPIT group vs. NT: 0.97 vs. 0.42 microg/mL, 2.5 vs. 0.46 microg/mL, 0.39 vs. 0.05 microg/mL and 15.0 vs. 5.5 microg/mL, respectively (P<0.05). There were no significant differences between EPIT and SCIT groups. The IgE/IgG2a ratio decreased significantly in the EPIT group for the four allergens from 70 to 58 (pollen), 175 to 26 (HDM), 5433 to 120 (OVA) and 49 to 6 (peanut), respectively (P<0.05). In mice sensitized to the four allergens tested, EPIT was as efficacious as SCIT, considered as the reference immunotherapy. These first results have to be confirmed by clinical studies.
Elsohaby, I; McClure, J T; Dow, N; Keefe, G P
2018-01-01
Heat-treatment of colostrum is a method developed to reduce calf exposure to pathogens. Infrared (IR) spectroscopy and Brix refractometers can be used for measuring colostral IgG concentration and assessing colostrum quality. To determine the impact of heat-treatment on accuracy of IR spectroscopy and Brix refractometers for measuring colostral IgG concentration and assessing colostrum quality before and after heat-treatment. A total of 60 Holstein dairy cows on 8 commercial dairy farms. A cross-sectional study was designed to determine the effect of heat-treatment at 60°C and 63°C each for 30 and 60 minutes duration on colostral IgG concentration measured by the reference radial immunodiffusion (RID) assay, IR spectroscopy, and digital and optical refractometers. Colostrum IgG concentration significantly decreased after heat-treatment at 63°C for 30 or 60 minutes as measured by RID, but the IgG values remained unchanged when measured by IR spectroscopy and refractometers. The lowest correlation coefficient found between IR spectroscopy (r = 0.70) and RID results was in colostrum heat-treated at 63°C for 60 minutes. For digital (r = 0.48) and optical (r = 0.50) refractometers, the lowest correlation coefficient was at 63°C for 30 minutes when compared to RID. The accuracy of the IR spectroscopy, digital and optical Brix refractometers was decreased from 91.7 to 80%, 81.7 to 45%, and 80 to 45%, respectively, when colostrum heat-treated at 63°C for 60 minutes. Radial immunodiffusion, IR spectroscopy, and Brix refractometers exhibit utility for measuring IgG concentration when colostrum heat-treated at 60°C but does not detect decrease IgG concentrations when heat-treated at 63°C. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Blacksell, Stuart D; Paris, Daniel H; Chierakul, Wirongrong; Wuthiekanun, Vanaporn; Teeratakul, Achara; Kantipong, Pacharee; Day, Nicholas P J
2012-03-01
Samples from 160 prospectively recruited febrile patients with typhus-like illness in an area of Thailand (Chiang Rai, northern Thailand) where scrub typhus is endemic were used to evaluate the diagnostic capabilities of four rapid immunochromatographic tests (ICTs) for the detection of Orientia tsutsugamushi IgM and total antibodies during acute scrub typhus infection. Of the 160 cases, 54 (34%) had been confirmed to have scrub typhus using the reference scrub typhus infection criteria (STIC), i.e., positive cell culture isolation, an admission IgM antibody titer of ≥1:12,800, a 4-fold rising IgM antibody titer, and/or positivity for ≥2 out of 3 PCR gene targets). The ICTs gave the following sensitivities and specificities: the Panbio IgM ICT, 46% (95% confidence interval [CI], 33 to 60) and 95% (95% CI, 89 to 98), respectively; the Standard Diagnostics IgM ICT, 68% (95% CI, 60 to 75) and 73% (95% CI, 68 to 78), respectively; the AccessBio IgM ICT, 56% (95% CI, 48 to 63) and 90% (95% CI, 87 to 94), respectively; and the AccessBio total antibody ABt ICT, 61% (95% CI, 53 to 68) and 68% (95% CI, 63 to 73), respectively. An isothermal loop amplification (LAMP) PCR assay for scrub typhus demonstrated a sensitivity of 52% (95% CI, 38 to 66) and a specificity of 94% (95% CI, 88 to 98). This study has revealed the diagnostic limitations of antibody-based assays in an acute care setting. However, the combination of ICTs with LAMP usually increased sensitivity with a minimal reduction in specificity. The best combination, the Panbio IgM ICT and LAMP, resulted in a sensitivity of 67% (95% CI, 53 to 79) and a specificity of 91% (95% CI, 83 to 95). The combination of antibody-based assays with DNA- or antigen-based tests shows promise for improved diagnostic sensitivity.
Whomersley, P; Schratzberger, M; Huxham, M; Bates, H; Rees, H
2007-01-01
Sewage sludge was disposed of in Liverpool Bay for over 100 years. Annual amounts increased from 0.5 million tonnes per annum in 1900 to approximately 2 million tonnes per annum by 1995. Macrofauna and a suite of environmental variables were collected at a station adjacent to, and a reference station distant from, the disposal site over 13 years, spanning a pre- (1990-1998) and post- (1999-2003) cessation period. Univariate and multivariate analyses of the time-series data showed significant community differences between reference and disposal site stations and multivariate analyses revealed station-specific community development post-disposal. Temporal variability of communities collected at the disposal station post-cessation was higher than during years of disposal, when temporally stable dominance patterns of disturbance-tolerant species had established. Alterations of community structure post-disturbance reflected successional changes possibly driven by facilitation. Subtle faunistic changes at the Liverpool Bay disposal site indicate that the near-field effects of the disposal of sewage sludge were small and therefore could be considered environmentally acceptable.
Design and development of electric vehicle charging station equipped with RFID
NASA Astrophysics Data System (ADS)
Panatarani, C.; Murtaddo, D.; Maulana, D. W.; Irawan, S.; Joni, I. M.
2016-02-01
This paper reports the development of electric charging station from distributed renewable for electric vehicle (EV). This designed refer to the input voltage standard of IEC 61851, plugs features of IEC 62196 and standard communication of ISO 15118. The developed electric charging station used microcontroller ATMEGA8535 and RFID as controller and identifier of the EV users, respectively. The charging station successfully developed as desired features for electric vehicle from renewable energy resources grid with solar panel, wind power and batteries storage.
High order GPS base station support for Rhode Island
DOT National Transportation Integrated Search
2001-09-01
The University of Rhode Island (URI) upgraded its Global Positioning System (GPS) Base Station to provide round-the-clock Internet access to survey-grade (+/- 2 cm accuracy) reference files using a web-based data distribution system. In August 2000, ...
NASA Astrophysics Data System (ADS)
Wang, Siyao; Li, Bofeng; Li, Xingxing; Zang, Nan
2018-01-01
Integer ambiguity fixing with uncalibrated phase delay (UPD) products can significantly shorten the initialization time and improve the accuracy of precise point positioning (PPP). Since the tracking arcs of satellites and the behavior of atmospheric biases can be very different for the reference networks with different scales, the qualities of corresponding UPD products may be also various. The purpose of this paper is to comparatively investigate the influence of different scales of reference station networks on UPD estimation and user ambiguity resolution. Three reference station networks with global, wide-area and local scales are used to compute the UPD products and analyze their impact on the PPP-AR. The time-to-first-fix, the unfix rate and the incorrect fix rate of PPP-AR are analyzed. Moreover, in order to further shorten the convergence time for obtaining precise positioning, a modified partial ambiguity resolution (PAR) and corresponding validation strategy are presented. In this PAR method, the ambiguity subset is determined by removing the ambiguity one by one in the order of ascending elevations. Besides, for static positioning mode, a coordinate validation strategy is employed to enhance the reliability of the fixed coordinate. The experiment results show that UPD products computed by smaller station network are more accurate and lead to a better coordinate solution; the PAR method used in this paper can shorten the convergence time and the coordinate validation strategy can improve the availability of high precision positioning.
Hanaire, Helene; Bertrand, Monelle; Guerci, Bruno; Anduze, Yves; Guillaume, Eric; Ritz, Patrick
2011-06-01
Obesity surgery elicits complex changes in glucose metabolism that are difficult to observe with discontinuous glucose measurements. We aimed to evaluate glucose variability after gastric bypass by continuous glucose monitoring (CGM) in a real-life setting. CGM was performed for 4.2 ± 1.3 days in three groups of 10 subjects each: patients who had undergone gastric bypass and who were referred for postprandial symptoms compatible with mild hypoglycemia, nonoperated diabetes controls, and healthy controls. The maximum interstitial glucose (IG), SD of IG values, and mean amplitude of glucose excursions (MAGE) were significantly higher in operated patients and in diabetes controls than in healthy controls. The time to the postprandial peak IG was significantly shorter in operated patients (42.8 ± 6.0 min) than in diabetes controls (82.2 ± 11.1 min, P = 0.0002), as were the rates of glucose increase to the peak (2.4 ± 1.6 vs. 1.2 ± 0.3 mg/mL/min; P = 0.041). True hypoglycemia (glucose <60 mg/dL) was rare: the symptoms were probably more related to the speed of IG decrease than to the glucose level achieved. Half of the operated patients, mostly those with a diabetes background before surgery, had postprandial glucose concentrations above 200 mg/dL (maximum IG, 306 ± 59 mg/dL), in contrast to the normal glucose concentrations in the fasting state and 2 h postmeal. Glucose variability is exaggerated after gastric bypass, combining unusually high and early hyperglycemic peaks and rapid IG decreases. This might account for postprandial symptoms mimicking hypoglycemia but often seen without true hypoglycemia. Early postprandial hyperglycemia might be underestimated if glucose measurements are done 2 h postmeal.
Kukkonen, A K; Pelkonen, A S; Mäkinen-Kiljunen, S; Voutilainen, H; Mäkelä, M J
2015-10-01
Component-resolved diagnostics offers a modern tool in peanut allergy, but studies applying consistently double-blind placebo-controlled challenges are lacking. We aimed to optimize diagnostics for moderate-to-severe peanut allergy in a birch-endemic region and to create an oral-peanut challenge with its allergen activity characterized. We performed double-blind placebo-controlled peanut challenges for a referred sample of 6- to 18-year-olds with peanut sensitization or a high suspicion of peanut allergy, including anaphylaxis. We measured specific IgE (sIgE) to Ara h 1, 2, 3, 6, 8, and 9. Testing of allergen activity of the challenge products was by IgE microarray inhibition. Of the 102 patients, 69 were challenge positive: 25 (36%) had severe, 36 (52%) moderate, and 8 (12%) mild symptoms; 38 (37%) received adrenalin. SIgE to Ara h 6 AUC 0.98 (95%CI, 0.96-1.00) was the best marker of moderate-to-severe allergy. When sIgE to Ara h 2 and Ara h 6 was measured together, all (100%) severe reactions at low doses were successfully diagnosable. SIgE to Ara h 8 had no diagnostic value, AUC 0.42 (95%CI, 0.30-0.52). Both nonroasted and roasted peanut inhibited 100% of IgE binding to Ara h 1, 2, 3, and 6. Nonroasted peanut inhibited 87% of IgE binding to Ara h 8, roasted inhibited 30%. The products lacked Ara h 9 activity. Co-sensitization to Ara h 2 and Ara h 6 was associated with severe reactions distinguishing severe allergy from mild symptoms. SIgE to Ara h 8 added no diagnostic value. Component-resolved diagnostics reduce the need for oral challenges in peanut allergy. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Rota, Jennifer S.; Hickman, Carole J.; Mercader, Sara; Redd, Susan; McNall, Rebecca J.; Williams, Nobia; McGrew, Marcia; Walls, M. Laura; Rota, Paul A.; Bellini, William J.
2016-01-01
In the United States, approximately 9% of the measles cases reported from 2012 to 2014 occurred in vaccinated individuals. Laboratory confirmation of measles in vaccinated individuals is challenging since IgM assays can give inconclusive results. Although a positive reverse transcription (RT)-PCR assay result from an appropriately timed specimen can provide confirmation, negative results may not rule out a highly suspicious case. Detection of high-avidity measles IgG in serum samples provides laboratory evidence of a past immunologic response to measles from natural infection or immunization. High concentrations of measles neutralizing antibody have been observed by plaque reduction neutralization (PRN) assays among confirmed measles cases with high-avidity IgG, referred to here as reinfection cases (RICs). In this study, we evaluated the utility of measuring levels of measles neutralizing antibody to distinguish RICs from noncases by receiver operating characteristic curve analysis. Single and paired serum samples with high-avidity measles IgG from suspected measles cases submitted to the CDC for routine surveillance were used for the analysis. The RICs were confirmed by a 4-fold rise in PRN titer or by RT-quantitative PCR (RT-qPCR) assay, while the noncases were negative by both assays. Discrimination accuracy was high with serum samples collected ≥3 days after rash onset (area under the curve, 0.953; 95% confidence interval [CI], 0.854 to 0.993). Measles neutralizing antibody concentrations of ≥40,000 mIU/ml identified RICs with 90% sensitivity (95% CI, 74 to 98%) and 100% specificity (95% CI, 82 to 100%). Therefore, when serological or RT-qPCR results are unavailable or inconclusive, suspected measles cases with high-avidity measles IgG can be confirmed as RICs by measles neutralizing antibody concentrations of ≥40,000 mIU/ml. PMID:27335386
Outbreak of scrub typhus in Puducherry & Tamil Nadu during cooler months
Stephen, Selvaraj; Sangeetha, Balakrishnan; Ambroise, Stanley; Sarangapani, Kengamuthu; Gunasekaran, Dhandapany; Hanifah, Mohamed; Somasundaram, Subramanian
2015-01-01
Background & objectives: The southern part of India has witnessed an increase in scrub typhus (ST) during the past ten years. ST outbreaks occurred during winter months but at intervals of one to three years. With only a few reports of ST in Puducherry, this study was undertaken to look for the persistence of ST cases in Puducherry and Tamil Nadu in the winter months. Methods: During relatively cooler months of September, 2012 to March, 2013, a total of 45 patients with fever and clinical suspicion of ST and who provided both acute and convalescent blood samples were included. Total WBC, platelet counts, serum creatinine, liver enzymes levels and a rapid immunochromatographic test (RICT) for ST were first done. Paired serum samples were analysed by two specific tests - ST IgM and IgG ELISA- and a non-specific, but widely used Weil-Felix (WF) test. Results: Of the 45 patients, 21 adults and seven children were confirmed as ST based on clinical and laboratory findings, and positivity in specific serological test(s). Setting ST IgM and IgG ELISA as reference, the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for RICT were 91.67, 85.71 per cent; 90.48, 100 per cent; 91.67, 100 per cent and 90.48, 80.95 per cent, respectively. Similarly, for WF the values were 83.33, 75 per cent; 95.24, 100 per cent; 95.24, 100 per cent and 83.33, 70.83 per cent, respectively. Interpretation & conclusions: ST continues to persist in the cooler months in Puducherry and neighbouring Tamil Nadu with fever and myalgia as prominent features. None of the tests evaluated in this study was found to be ideal, but ST IgM/IgG ELISA was useful for batch testing and the non-specific WF test can be used in resource poor settings. PMID:26658595
Minet, V; Bailly, N; Douxfils, J; Osselaer, J C; Laloy, J; Chatelain, C; Elalamy, I; Chatelain, B; Dogné, J M; Mullier, F
2013-09-01
Early diagnosis of immune heparin-induced thrombocytopenia (HIT) is challenging. HemosIL® AcuStar HIT and heparin-induced multiple electrode aggregometry (HIMEA) were recently proposed as rapid diagnostic methods. We conducted a study to assess performances of AcuStar HIT-IgG (PF4-H) and AcuStar HIT-Ab (PF4-H). The secondary objective was to compare the performances of the combination of Acustar HIT and HIMEA with standardised clinical diagnosis. Sera of 104 suspected HIT patients were retrospectively tested with AcuStar HIT. HIMEA was performed on available sera (n=81). The clinical diagnosis was established by analysing in a standardized manner the patient's medical records. These tests were also compared with PF4-Enhanced®, LTA, and SRA in subsets of patients. Thresholds were determined using ROC curve analysis with clinical outcome as reference. Using the recommended thresholds (1.00AU), the negative predictive value (NPV) of HIT-IgG and HIT-Ab were 100.0% (95% CI: 95.9%-100.0% and 95.7%-100.0%). The positive predictive value (PPV) were 64.3% (95% CI: 35.1%-87.2.2%) and 45.0% (95% CI: 23.2%-68.6%), respectively. Using our thresholds (HIT-IgG: 2.89AU, HIT-Ab: 9.41AU), NPV of HIT-IgG and HIT-Ab were 100.0% (95% CI: 96.0%-100.0% and 96.1%-100.0%). PPV were 75.0% (95% CI: 42.7%-94.5%) and 81.8% (95% CI: 48.3%-97.7%), respectively. Of the 79 patients with a medium-high pretest probability score, 67 were negative using HIT-IgG (PF4-H) test at our thresholds. HIMEA was performed on HIT-IgG positive patients. Using this combination, only one patient on 79 was incorrectly diagnosed. Acustar HIT showed good performances to exclude the diagnosis of HIT. Combination with HIMEA improves PPV. Copyright © 2013 Elsevier Ltd. All rights reserved.
Increasing Cervical Cancer Screening Coverage: A Randomised, Community-Based Clinical Trial.
Acera, Amelia; Manresa, Josep Maria; Rodriguez, Diego; Rodriguez, Ana; Bonet, Josep Maria; Trapero-Bertran, Marta; Hidalgo, Pablo; Sànchez, Norman; de Sanjosé, Silvia
2017-01-01
Opportunistic cervical cancer screening can lead to suboptimal screening coverage. Coverage could be increased after a personalised invitation to the target population. We present a community randomized intervention study with three strategies aiming to increase screening coverage. The CRICERVA study is a community-based clinical trial to improve coverage of population-based screening in the Cerdanyola SAP area in Barcelona.A total of 32,858 women residing in the study area, aged 30 to 70 years were evaluated. A total of 15,965 women were identified as having no registration of a cervical cytology in the last 3.5 years within the Public Health data base system. Eligible women were assigned to one of four community randomized intervention groups (IGs): (1) (IG1 N = 4197) personalised invitation letter, (2) (IG2 N = 3601) personalised invitation letter + informative leaflet, (3) (IG3 N = 6088) personalised invitation letter + informative leaflet + personalised phone call and (4) (Control N = 2079) based on spontaneous demand of cervical cancer screening as officially recommended. To evaluate screening coverage, we used heterogeneity tests to compare impact of the interventions and mixed logistic regression models to assess the age effect. We refer a "rescue" visit as the screening visit resulting from the study invitation. Among the 13,886 women in the IGs, 2,862 were evaluated as having an adequate screening history after the initial contact; 4,263 were lost to follow-up and 5,341 were identified as having insufficient screening and thus being eligible for a rescue visit. All intervention strategies significantly increased participation to screening compared to the control group. Coverage after the intervention reached 84.1% while the control group reached 64.8%. The final impact of our study was an increase of 20% in the three IGs and of 9% in the control group (p<0.001). Within the intervention arms, age was an important determinant of rescue visits showing a statistical interaction with the coverage attained in the IGs. Within the intervention groups, final screening coverage was significantly higher in IG3 (84.4%) (p<0.001). However, the differences were more substantial in the age groups 50-59 and those 60+. The highest impact of the IG3 intervention was observed among women 60+ y.o with 32.0% of them being rescued for screening. The lowest impact of the interventions was in younger women. The study confirms that using individual contact methods and assigning a fixed screening date notably increases participation in screening. The response to the invitation is strongly dependent on age. ClinicalTrials.gov NCT01373723.
Buczinski, S; Fecteau, G; Chigerwe, M; Vandeweerd, J M
2016-06-01
Calves are highly dependent of colostrum (and antibody) intake because they are born agammaglobulinemic. The transfer of passive immunity in calves can be assessed directly by dosing immunoglobulin G (IgG) or by refractometry or Brix refractometry. The latter are easier to perform routinely in the field. This paper presents a protocol for a systematic review meta-analysis to assess the diagnostic accuracy of refractometry or Brix refractometry versus dosage of IgG as a reference standard test. With this review protocol we aim to be able to report refractometer and Brix refractometer accuracy in terms of sensitivity and specificity as well as to quantify the impact of any study characteristic on test accuracy.
NASA Astrophysics Data System (ADS)
Kreemer, C. W.; Hammond, W. C.; Blewitt, G.
2009-12-01
The Sierra Nevada - Great Valley (SNGV) micro-plate has long been recognized as a tectonically rigid, though mobile, entity within the Pacific - North America plate boundary zone. The motion of the SNGV relative to stable North America (and the Colorado Plateau) provides the kinematic boundary condition for, and perhaps drives, the deformation in the Basin and Range Province (BRP) and Walker Lane. In the north the motion of the SNGV is aligned with the Mohawk Valley fault zone, which could have a slip rate of over a few mm/yr. The crest of the Sierras marks the SNGV’s eastern edge, but the obliquity between orientation of this boundary and the block’s motion implies an expected increase in rangefront-normal extension from the northern to southern Walker Lane. We use new GPS data from the EarthScope Plate Boundary Observatory (PBO) and our own semi-continuous MAGNET network to revisit the following questions: 1) Do the data still support rigidity of the SNGV?; 2) How far east does the rigidity extend and how does this relate to SNGV lithology?; 3) How does the direction of SNGV motion relate to the strike of its eastern margin and observed strain partitioning (and its along strike variation) in the Walker Lane?; and 4) How is SNGV-BRP motion accommodated between the Walker Lane and the Cascadia forearc? We analyze data from all the available continuous GPS sites in the greater SNGV region, including new data from PBO, as well as data from MAGNET. All data are processed with the GIPSY-OASIS II precise point positioning software using recently reprocessed orbits from JPL's IGS Analysis Center. The processing includes satellite and station antenna calibrations and all data have the phase ambiguities fixed using the Ambizap algorithm. Positions are estimated in our custom-made North America reference frame in which continental-scale common-mode errors are removed. Velocities and uncertainties are estimated using the CATS software in which we assuming an error model with flicker plus white noise. Many stations in the Great Valley show anomalous horizontal motions compared to the most stable stations in the Sierra Nevada Mountains. These motions are likely due to hydrological effects in the Great Valley, which can be seen in the significant subsidence that occurs at these stations. Consequently, there are a relatively small number of stations that should be used to constrain the SNGV rigid body rotation. We find that stations in the southernmost Sierra Nevada Mountains have a northward motion of >1 mm/yr relative to the central and northern Sierras. This could partly be explained in terms of regional post-seismic viscoelastic relaxation from recent earthquakes (e.g. Kern County 1952, Landers, 1992, Hector Mine1999), but may also reflect the region’s anomalous mantle dynamics.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Command; the Naval Investigative Service Command; the U.S. Air Force Office of Special Investigations; and the Defense Criminal Investigative Service, Office of the IG, DoD (OIG, DoD). 2. Significant. Refers... expeditiously the Defense Investigative Service (DIS) of any investigations that develop evidence that would...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Command; the Naval Investigative Service Command; the U.S. Air Force Office of Special Investigations; and the Defense Criminal Investigative Service, Office of the IG, DoD (OIG, DoD). 2. Significant. Refers... expeditiously the Defense Investigative Service (DIS) of any investigations that develop evidence that would...
The Global GNSS, SLR, VLBI, and DORIS Networks and their Support of GGOS: IGS+ILRS+IVS+IDS
NASA Technical Reports Server (NTRS)
Noll, Carey
2008-01-01
The global network of the International GNSS Service (IGS), the International Laser Ranging Service (ILRS), the International VLBI Service for Geodesy and Astrometry (IVS), and the International DORIS Service (IDS) are part of the ground-based infrastructure for GGOS. The observations obtained from these global networks provide for the determination and maintenance of the International Terrestrial Reference Frame (ITRF), an accurate set of positions and velocities that provides a stable coordinate system allowing scientists ts to link measurements over space and time. Many of these sites offer co-location of two or more techniques. Co-location provides integration of technique-specific networks into the ITRF as well as an assessment/validation of the quality and accuracy of the resulting measurements. As of fall 2008, these networks consisted of 410 GNSS sites, 42 laser ranging sites, 45 VLBI sites, and 58 DORIS sites. This poster will illustrate the global coverage of these networks, highlighting inter-technique co-locations, and show the importance of these networks 60 the underlying goals of GGOS including providing the observational basis to maintain a stable, accurate, global reference frame.
Lundström, Emeli; Gustafsson, Johanna T; Jönsen, Andreas; Leonard, Dag; Zickert, Agneta; Elvin, Kerstin; Sturfelt, Gunnar; Nordmark, Gunnel; Bengtsson, Anders A; Sundin, Ulf; Källberg, Henrik; Sandling, Johanna K; Syvänen, Ann-Christine; Klareskog, Lars; Gunnarsson, Iva; Rönnblom, Lars; Padyukov, Leonid; Svenungsson, Elisabet
2013-06-01
Vascular disease is common in systemic lupus erythematosus (SLE) and patients with antiphospholipid antibodies (aPL) are at high risk to develop arterial and venous thrombosis. Since HLA class II genotypes have been linked to the presence of pro-thrombotic aPL, we investigated the relationship between HLA-DRB1 alleles, aPL and vascular events in SLE patients. 665 SLE patients of Caucasian origin and 1403 controls were included. Previous manifestations of ischaemic heart disease, ischaemic cerebrovascular disease (ICVD) and venous thromboembolism (together referred to as any vascular events (AVE)) were tabulated. aPL were measured with ELISA. Two-digit HLA-DRB1 typing was performed by sequence-specific primer-PCR. HLA-DRB1*04 was more frequent among SLE patients with ICVD compared to unaffected patients. This association remained after adjustment for known traditional cardiovascular risk factors. HLA-DRB1*13 was associated with AVE. All measured specificities of aPL-cardiolipin IgG and IgM, β2-glycoprotein-1 IgG, prothrombin (PT) IgG and a positive lupus anticoagulant test were associated with HLA-DRB1*04-while HLA-DRB1*13 was associated with IgG antibodies (β2-glycoprotein-1, cardiolipin and PT). In patients with the combined risk alleles, HLA-DRB1*04/*13, there was a significant additive interaction for the outcomes AVE and ICVD. The HLA-DRB1*04 and HLA-DRB1*13 alleles are associated with vascular events and an aPL positive immune-phenotype in SLE. Results demonstrate that a subset of SLE patients is genetically disposed to vascular vulnerability.
Assessing Immunity to Rubella Virus: a Plea for Standardization of IgG (Immuno)assays
Bouthry, Elise; Huzly, Daniela; Ogee-Nwankwo, Adaeze; Hao, LiJuan; Adebayo, Adebola; Icenogle, Joseph; Sarasini, Antonella; Revello, Maria Grazia; Grangeot-Keros, Liliane
2016-01-01
Immunity to rubella virus (RV) is commonly determined by measuring specific immunoglobulin G (RV IgG). However, RV IgG results and their interpretation may vary, depending on the immunoassay, even though most commercial immunoassays (CIAs) have been calibrated against an international standard and results are reported in international units per milliliter. A panel of 322 sera collected from pregnant women that tested negative or equivocal for RV IgG in a prior test (routine screening) was selected. This panel was tested with two reference tests, immunoblotting (IB) and neutralization (Nt), and with 8 CIAs widely used in Europe. IB and Nt gave concordant results on 267/322 (82.9%) sera. Of these, 85 (26.4%) sera were negative and 182 (56.5%) sera were positive for both tests. All 85 IB/Nt-negative samples were classified as negative with all CIAs. Of the 182 IB/Nt-positive samples, 25.3 to 61.5% were classified as equivocal and 6 to 64.8% were classified as positive with the CIAs. Wide variations in titers in international units per milliliter were observed. In our series, more than half of the women considered susceptible to RV based on CIA results tested positive for RV antibodies by IB/Nt. Our data suggest that (i) sensitivity of CIAs could be increased by considering equivocal results as positive and (ii) the definition of immunity to RV as the 10-IU/ml usual cutoff as well as the use of quantitative results for clinical decisions may warrant reconsideration. A better standardization of CIAs for RV IgG determination is needed. PMID:27147722
DOE Office of Scientific and Technical Information (OSTI.GOV)
El-Sherif, O; Xhaferllari, I; Patrick, J
2014-08-15
Introduction: Long-term cardiac side effects in left-sided breast cancer patients (BREL) after post-operative radiotherapy has become one of the most debated issues in radiation oncology. Through breathing-adapted radiotherapy the volume of the heart exposed to radiation can be significantly reduced by delivering the radiation only at the end of inspiration phase of the respiratory cycle, this is referred to as inspiration gating (IG). The purpose of this study is to quantify the potential reduction in cardiac exposure during IG compared to conventional BREL radiotherapy and to assess the dosimetric impact of cardiac motion due to natural breathing. Methods: 24 BRELmore » patients treated with tangential parallel opposed photon beams were included in this study. All patients received a standard fast helical planning CT (FH-CT) and a 4D-CT. Treatment plans were created on the FH-CT using a clinical treatment planning system. The original treatment plan was then superimposed onto the end of inspiration CT and all 10 phases of the 4D-CT to quantify the dosimetric impact of respiratory motion and IG through 4D dose accumulation. Results: Through IG the mean dose to the heart, left ventricle, and left anterior descending artery (LAD) can be reduced in comparison to the clinical standard BREL treatment by as much as 8.39%, 10.11%, and 13.71% respectively (p < 0.05). Conclusion: Failure to account for respiratory motion can lead to under or overestimation in the calculated DVH for the heart, and it's sub-structures. IG can reduce cardiac exposure especially to the LAD during BREL radiotherapy.« less
Performance of Dengue Diagnostic Tests in a Single-Specimen Diagnostic Algorithm.
Hunsperger, Elizabeth A; Muñoz-Jordán, Jorge; Beltran, Manuela; Colón, Candimar; Carrión, Jessica; Vazquez, Jesus; Acosta, Luz Nereida; Medina-Izquierdo, Juan F; Horiuchi, Kalanthe; Biggerstaff, Brad J; Margolis, Harold S
2016-09-15
Anti-dengue virus (DENV) immunoglobulin M (IgM) seroconversion has been the reference standard for dengue diagnosis. However, paired specimens are rarely obtained, and the interval for this testing negates its usefulness in guiding clinical case management. The presence of DENV viremia and appearance of IgM during the febrile phase of dengue provides the framework for dengue laboratory diagnosis by using a single serum specimen. Archived paired serum specimens (n = 1234) from patients with laboratory-confirmed dengue from 2005 through 2011 were used to determine the diagnostic performance of real-time reverse transcription polymerase chain reaction (RT-PCR), for detection of DENV serotypes 1-4, and enzyme-linked immunosorbent assays (ELISAs), for detection of DENV nonstructural protein 1 (NS1) antigen and anti-DENV IgM. During 1-3 days after illness onset, real-time RT-PCR and NS1 antigen testing detected 82%-69% and 90%-84% of cases, respectively, as viremia levels declined, while anti-DENV IgM ELISA detected 5%-41% of cases as antibody appeared. Over the 10-day period of the febrile phase of dengue, the cumulative effect of using these 3 types of tests in a diagnostic algorithm confirmed ≥90% of dengue cases. The use of molecular or NS1 antigen tests to detect DENV and one to detect anti-DENV IgM in a single serum specimen collected during the first 10 days of illness accurately identified ≥90% of dengue primary and secondary cases. Published by Oxford University Press for the Infectious Diseases Society of America 2016. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Rubio, A; Vivinus-Nébot, M; Bourrier, T; Saggio, B; Albertini, M; Bernard, A
2011-01-01
Oral challenges are required to establish the persistence or resolution of IgE-mediated cow's milk allergy (CMA). Determining the appropriate timing for challenging is the main difficulty. The benefit of the basophil activation test (BAT) in predicting a child's reaction to the oral challenge was evaluated and compared to the specific IgE and skin prick tests' (SPT) results. One hundred and twelve consecutive children with CMA admitted for an oral challenge to reassess their allergy were included. Allergen-induced basophil activation was detected as a CD63-upregulation by flow cytometry. Thirty-six children (32%) had a positive oral challenge. The percentage of activated basophils in patients with a positive challenge (mean = 20.9; SD = 18.8) was significantly higher than that of patients with a negative challenge (mean = 3.9; SD = 9.8, P < 0.0001), and was well correlated with the eliciting dose of cow's milk (P < 0.0001). The BAT had an efficiency of 90%, a sensitivity of 91%, a specificity of 90%, and positive and negative predictive values of 81% and 96% in detecting persistently allergic patients. The area under the ROC curve was 0.866. These scores were higher than those obtained with SPT and IgE values, whichever positivity cut-point was chosen. Referring to a decisional algorithm combining BAT, specific IgE and SPT allowed the correct identification of 94% of patients as tolerant or persistently allergic to cow's milk proteins (CMP) in our cohort. The BAT could be a valuable tool in the management of paediatric CMA in addition to specific IgE quantification and SPT, by contributing in determining whether an oral challenge can safely be undertaken. © 2010 John Wiley & Sons A/S.
Assessing Immunity to Rubella Virus: a Plea for Standardization of IgG (Immuno)assays.
Bouthry, Elise; Furione, Milena; Huzly, Daniela; Ogee-Nwankwo, Adaeze; Hao, LiJuan; Adebayo, Adebola; Icenogle, Joseph; Sarasini, Antonella; Revello, Maria Grazia; Grangeot-Keros, Liliane; Vauloup-Fellous, Christelle
2016-07-01
Immunity to rubella virus (RV) is commonly determined by measuring specific immunoglobulin G (RV IgG). However, RV IgG results and their interpretation may vary, depending on the immunoassay, even though most commercial immunoassays (CIAs) have been calibrated against an international standard and results are reported in international units per milliliter. A panel of 322 sera collected from pregnant women that tested negative or equivocal for RV IgG in a prior test (routine screening) was selected. This panel was tested with two reference tests, immunoblotting (IB) and neutralization (Nt), and with 8 CIAs widely used in Europe. IB and Nt gave concordant results on 267/322 (82.9%) sera. Of these, 85 (26.4%) sera were negative and 182 (56.5%) sera were positive for both tests. All 85 IB/Nt-negative samples were classified as negative with all CIAs. Of the 182 IB/Nt-positive samples, 25.3 to 61.5% were classified as equivocal and 6 to 64.8% were classified as positive with the CIAs. Wide variations in titers in international units per milliliter were observed. In our series, more than half of the women considered susceptible to RV based on CIA results tested positive for RV antibodies by IB/Nt. Our data suggest that (i) sensitivity of CIAs could be increased by considering equivocal results as positive and (ii) the definition of immunity to RV as the 10-IU/ml usual cutoff as well as the use of quantitative results for clinical decisions may warrant reconsideration. A better standardization of CIAs for RV IgG determination is needed. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Ramírez-Santana, Carolina; Pérez-Cano, Francisco J; Castellote, Cristina; Castell, Margarida; Rivero, Montserrat; Rodríguez-Palmero, María; Franch, Angels
2009-09-01
Conjugated linoleic acid (CLA) has been reported to exert beneficial physiological effects on body composition and the immune system. However, little information is available on the influence of CLA on immune function during early life periods. The present study evaluates the effect of feeding an 80:20 mixture of cis-9, trans-11- and trans-10, cis-12-CLA isomers during gestation and suckling on the systemic immune response of weaned Wistar rats. Pups received dietary CLA from dams through the placental barrier and during suckling by breast milk (group A) or by oral administration (group B). Pups from group C only received CLA during suckling by oral administration. Group D constituted the reference group. Milk from dams fed the CLA diet had a high content of CLA and higher IgA and IgG concentrations than rats fed the standard diet. The plasma of pups from groups A, B and C showed six, twelve and nine times higher content of the cis-9, trans-11-CLA isomer than that of the group D pups. Rats from group A exhibited higher serum IgG concentrations than rats from the rest of the groups (22.14 (SEM 2.14) v. about 5 mg/ml; P < 0.05), whereas rats from groups A and B showed approximately 2-fold higher splenocyte IgM production than rats from groups C and D. However, CLA supplementation did not influence significantly the splenocyte proliferative response or cytokine secretion. Supplementation during gestation and suckling with an 80:20 cis-9, trans-11-trans-10, cis-12 CLA mix enhances the production of the main in vivo and in vitro Ig isotypes in Wistar rats.