Demand illumination control apparatus
NASA Technical Reports Server (NTRS)
Warren, Carl (Inventor); Arline, Jimmie (Inventor); LaPalme, Julius (Inventor)
1981-01-01
Solar illuminating compensating apparatus is disclosed whereby the interior of a building is illuminated to a substantially constant, predetermined level of light intensity by a combination of natural illumination from the sun and artificial illumination from electricity wherein the intensity of said artificial illumination is controlled by fully electronic means which increases the level of artificial illumination when the natural illumination is inadequate and vice versa.
Price, Jeffery R.; Bingham, Philip R.
2005-11-08
Systems and methods are described for rapid acquisition of fused off-axis illumination direct-to-digital holography. A method of recording a plurality of off-axis object illuminated spatially heterodyne holograms, each of the off-axis object illuminated spatially heterodyne holograms including spatially heterodyne fringes for Fourier analysis, includes digitally recording, with a first illumination source of an interferometer, a first off-axis object illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis; and digitally recording, with a second illumination source of the interferometer, a second off-axis object illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis.
NASA Astrophysics Data System (ADS)
Shen, Y. Z.; Guo, S. S.; Ai, W. D.; Tang, Y. K.
2014-07-01
Effects of illuminants and illumination time on the growth of lettuce were researched. Red-blue light-emitting diodes (LEDs, 90% red light +10% blue light) and white light fluorescent (WF) lamps were compared as the illuminants for plant cultivation. Under each type of illuminant, lettuce was grown at 4 illumination times: 12 h, 16 h, 20 h and 24 h, with the same light intensity of 600 μmolm-2s-1. The leaf net photosynthetic rate (Pn) under the two illuminants was comparable but the shape of lettuce was obviously affected by the illuminant. The WF lamps produced more compact plant, while red-blue LED resulted in less but longer leaves. However, the total leaf area was not significantly affected by the illuminant. The red-blue LED produced nearly same aboveground biomass with far less energy consumption relative to WF lamps. The underground biomass was lowered under red-blue LED in comparison with WF lamps. Red-blue LED could improve the nutritional quality of lettuce by increasing the concentration of soluble sugar and vitamin C (VC) and reducing the concentration of nitrate. Under each type of illuminant, longer illumination time resulted in higher Pn, more leaves and larger leaf area. The total chlorophyll concentration increased while the concentration ratio of chlorophyll a/b decreased with the extension of illumination time. Illumination time had highly significant positive correlation with biomass. Moreover, when total daily light input was kept the same, longer illumination time increased the biomass significantly as well. In addition, longer illumination time increased the concentration of crude fiber, soluble sugar and VC and reduced the concentration of nitrate. In summary, red-blue LEDs and 24 h illumination time were demonstrated to be more suitable for lettuce cultivation in the controlled environment.
Surface color perception under two illuminants: the second illuminant reduces color constancy
NASA Technical Reports Server (NTRS)
Yang, Joong Nam; Shevell, Steven K.
2003-01-01
This study investigates color perception in a scene with two different illuminants. The two illuminants, in opposite corners, simultaneously shine on a (simulated) scene with an opaque dividing wall, which controls how much of the scene is illuminated by each source. In the first experiment, the height of the dividing wall was varied. This changed the amount of each illuminant reaching objects on the opposite side of the wall. Results showed that the degree of color constancy decreased when a region on one side of the wall had cues to both illuminants, suggesting that cues from the second illuminant are detrimental to color constancy. In a later experiment, color constancy was found to improve when the specular highlight cues from the second illuminant were altered to be consistent with the first illuminant. This corroborates the influence of specular highlights in surface color perception, and suggests that the reduced color constancy in the first experiment is due to the inconsistent, though physically correct, cues from the two illuminants.
Arnold, Sarah E J; Chittka, Lars
2012-07-01
Patchy illumination presents foraging animals with a challenge, as the targets being sought may appear to vary in colour depending on the illumination, compromising target identification. We sought to explore how the bumblebee Bombus terrestris copes with tasks involving flower colour discrimination under patchy illumination. Light patches varied between unobscured daylight and leaf-shade, as a bee might encounter in and around woodland. Using a flight arena and coloured filters, as well as one or two different colours of artificial flower, we quantified how bees chose to forage when presented with foraging tasks under patchy illumination. Bees were better at discriminating a pair of similar colours under simulated unobscured daylight illumination than when foraging under leaf-shade illumination. Accordingly, we found that bees with prior experience of simulated daylight but not leaf-shade illumination initially preferred to forage in simulated daylight when all artificial flowers contained rewards as well as when only one colour was rewarding, whereas bees with prior experience of both illuminants did not exhibit this preference. Bees also switched between illuminants less than expected by chance. This means that bees prefer illumination conditions with which they are familiar, and in which rewarding flower colours are easily distinguishable from unrewarding ones. Under patchy illumination, colour discrimination performance was substantially poorer than in homogenous light. The bees' abilities at coping with patchy light may therefore impact on foraging behaviour in the wild, particularly in woodlands, where illumination can change over short spatial scales.
Topology-aware illumination design for volume rendering.
Zhou, Jianlong; Wang, Xiuying; Cui, Hui; Gong, Peng; Miao, Xianglin; Miao, Yalin; Xiao, Chun; Chen, Fang; Feng, Dagan
2016-08-19
Direct volume rendering is one of flexible and effective approaches to inspect large volumetric data such as medical and biological images. In conventional volume rendering, it is often time consuming to set up a meaningful illumination environment. Moreover, conventional illumination approaches usually assign same values of variables of an illumination model to different structures manually and thus neglect the important illumination variations due to structure differences. We introduce a novel illumination design paradigm for volume rendering on the basis of topology to automate illumination parameter definitions meaningfully. The topological features are extracted from the contour tree of an input volumetric data. The automation of illumination design is achieved based on four aspects of attenuation, distance, saliency, and contrast perception. To better distinguish structures and maximize illuminance perception differences of structures, a two-phase topology-aware illuminance perception contrast model is proposed based on the psychological concept of Just-Noticeable-Difference. The proposed approach allows meaningful and efficient automatic generations of illumination in volume rendering. Our results showed that our approach is more effective in depth and shape depiction, as well as providing higher perceptual differences between structures.
Synchrotron-based EUV lithography illuminator simulator
Naulleau, Patrick P.
2004-07-27
A lithographic illuminator to illuminate a reticle to be imaged with a range of angles is provided. The illumination can be employed to generate a pattern in the pupil of the imaging system, where spatial coordinates in the pupil plane correspond to illumination angles in the reticle plane. In particular, a coherent synchrotron beamline is used along with a potentially decoherentizing holographic optical element (HOE), as an experimental EUV illuminator simulation station. The pupil fill is completely defined by a single HOE, thus the system can be easily modified to model a variety of illuminator fill patterns. The HOE can be designed to generate any desired angular spectrum and such a device can serve as the basis for an illuminator simulator.
Seo, Hyejin; Nam, Dong Heun; Lee, Jong Yeon; Park, Su Jin; Kim, Yu Jeong; Kim, Seong-Woo; Chung, Tae-Young; Inoue, Makoto; Kim, Terry
2018-02-01
To evaluate macular photostress and visual experience between coaxial microscope illumination versus oblique intracameral illumination during cataract surgery. Gachon University Gil Hospital, Incheon, South Korea. Prospective case series. Consecutive patients who had cataract surgery using microscope illumination and intracameral illumination were included. The patients were asked to complete a questionnaire (seeing strong lights, feeling photophobia, feeling startled (fright) when seeing lights, seeing any colors, seeing any instruments or surgical procedures, and estimating intraoperative visual function) designed to describe their cataract surgery experience. The images projected on the retina of the model eye (rear view) with artificial opaque fragments in the anterior chamber during simulating cataract surgery were compared between the 2 illumination types. Sixty patients completed the questionnaire. Scores for strong lights, photophobia, fright, and color perception were significantly higher with microscope illumination than with intracameral illumination (all P < .001). More patients preferred the intracameral illumination (45 [75.0%]) to the microscope illumination (13 [21.7%]). In the rear-view images created in a model eye, only the bright microscope light in the center was seen without any lens image in the microscope illumination. However, in the intracameral illumination, the less bright light from the light pipe in the periphery and the lens fragments were seen more clearly. In a view of the patients' visual experience, oblique intracameral illumination caused less subjective photostress and was preferred over coaxial microscope illumination. Objective findings from the model-eye experiment correlated to the result of visual experience. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Electrohydrodynamically patterned colloidal crystals
NASA Technical Reports Server (NTRS)
Hayward, Ryan C. (Inventor); Poon, Hak F. (Inventor); Xiao, Yi (Inventor); Saville, Dudley A. (Inventor); Aksay, Ilhan A. (Inventor)
2003-01-01
A method for assembling patterned crystalline arrays of colloidal particles using ultraviolet illumination of an optically-sensitive semiconducting anode while using the anode to apply an electronic field to the colloidal particles. The ultraviolet illumination increases current density, and consequently, the flow of the colloidal particles. As a result, colloidal particles can be caused to migrate from non-illuminated areas of the anode to illuminated areas of the anode. Selective illumination of the anode can also be used to permanently affix colloidal crystals to illuminated areas of the anode while not affixing them to non-illuminated areas of the anode.
Pupillary efficient lighting system
Berman, Samuel M.; Jewett, Don L.
1991-01-01
A lighting system having at least two independent lighting subsystems each with a different ratio of scotopic illumination to photopic illumination. The radiant energy in the visible region of the spectrum of the lighting subsystems can be adjusted relative to each other so that the total scotopic illumination of the combined system and the total photopic illumination of the combined system can be varied independently. The dilation or contraction of the pupil of an eye is controlled by the level of scotopic illumination and because the scotopic and photopic illumination can be separately controlled, the system allows the pupil size to be varied independently of the level of photopic illumination. Hence, the vision process can be improved for a given level of photopic illumination.
Azlan, C A; Ng, K H; Anandan, S; Nizam, M S
2006-09-01
Illuminance level in the softcopy image viewing room is a very important factor to optimize productivity in radiological diagnosis. In today's radiological environment, the illuminance measurements are normally done during the quality control procedure and performed annually. Although the room is equipped with dimmer switches, radiologists are not able to decide the level of illuminance according to the standards. The aim of this study is to develop a simple real-time illuminance detector system to assist the radiologists in deciding an adequate illuminance level during radiological image viewing. The system indicates illuminance in a very simple visual form by using light emitting diodes. By employing the device in the viewing room, illuminance level can be monitored and adjusted effectively.
Pearce, Bradley; Crichton, Stuart; Mackiewicz, Michal; Finlayson, Graham D; Hurlbert, Anya
2014-01-01
The phenomenon of colour constancy in human visual perception keeps surface colours constant, despite changes in their reflected light due to changing illumination. Although colour constancy has evolved under a constrained subset of illuminations, it is unknown whether its underlying mechanisms, thought to involve multiple components from retina to cortex, are optimised for particular environmental variations. Here we demonstrate a new method for investigating colour constancy using illumination matching in real scenes which, unlike previous methods using surface matching and simulated scenes, allows testing of multiple, real illuminations. We use real scenes consisting of solid familiar or unfamiliar objects against uniform or variegated backgrounds and compare discrimination performance for typical illuminations from the daylight chromaticity locus (approximately blue-yellow) and atypical spectra from an orthogonal locus (approximately red-green, at correlated colour temperature 6700 K), all produced in real time by a 10-channel LED illuminator. We find that discrimination of illumination changes is poorer along the daylight locus than the atypical locus, and is poorest particularly for bluer illumination changes, demonstrating conversely that surface colour constancy is best for blue daylight illuminations. Illumination discrimination is also enhanced, and therefore colour constancy diminished, for uniform backgrounds, irrespective of the object type. These results are not explained by statistical properties of the scene signal changes at the retinal level. We conclude that high-level mechanisms of colour constancy are biased for the blue daylight illuminations and variegated backgrounds to which the human visual system has typically been exposed.
Lee, Alex C H; Elson, Daniel S; Neil, Mark A; Kumar, Sunil; Ling, Bingo W; Bello, Fernando; Hanna, George B
2009-03-01
Current arc-lamp illumination systems have a number of technical and ergonomic limitations. White light-emitting diodes (LEDs) are energy-efficient solid-state lighting devices which are small, durable and inexpensive. Their use as an alternative to arc-lamp light sources in minimal access surgery has not been explored. This study aims to develop an LED-based endo-illuminator and to determine its lighting characteristics for use in minimal access surgery. We developed an LED endo-illuminator using a white LED mounted at the tip of a steel rod. Offline image analysis was carried out to compare the illuminated field using the LED endo-illuminator or an arc-lamp based endoscope in terms of uniformity, shadow sharpness and overall image intensity. Direct radiometric power measurements in light intensity and stability were obtained. Visual perception of fine details at the peripheral endoscopic field was assessed by 13 subjects using the different illumination systems. Illumination from the LED endo-illuminator was more uniform compared to illumination from an arc-lamp source, especially at the closer distance of 4 cm (0.0006 versus 0.0028 arbitrary units--lower value indicates more uniform illumination). The shadows were also sharper (edge widths of 16 versus 44 pixels for the first edge and 15 versus 61 pixels for the second edge). The overall mean image intensity was higher (127 versus 100 arbitrary units) when using the autoshutter mode despite the lower direct radiometric power, about one tenth of the arc-lamp endoscopic system. The illumination was also more stable with less flickering (0.02% versus 5% of total power in non-DC components). Higher median scores on visual perception was also obtained (237 versus 157, p < 0.001). The LED endo-illuminator provides more uniform illumination with sharper shadows, less flickering and better illumination for visual perception than the arc-lamp-based system currently used.
NASA Astrophysics Data System (ADS)
Toadere, Florin
2017-12-01
A spectral image processing algorithm that allows the illumination of the scene with different illuminants together with the reconstruction of the scene's reflectance is presented. Color checker spectral image and CIE A (warm light 2700 K), D65 (cold light 6500 K) and Cree TW Series LED T8 (4000 K) are employed for scene illumination. Illuminants used in the simulations have different spectra and, as a result of their illumination, the colors of the scene change. The influence of the illuminants on the reconstruction of the scene's reflectance is estimated. Demonstrative images and reflectance showing the operation of the algorithm are illustrated.
Pearce, Bradley; Crichton, Stuart; Mackiewicz, Michal; Finlayson, Graham D.; Hurlbert, Anya
2014-01-01
The phenomenon of colour constancy in human visual perception keeps surface colours constant, despite changes in their reflected light due to changing illumination. Although colour constancy has evolved under a constrained subset of illuminations, it is unknown whether its underlying mechanisms, thought to involve multiple components from retina to cortex, are optimised for particular environmental variations. Here we demonstrate a new method for investigating colour constancy using illumination matching in real scenes which, unlike previous methods using surface matching and simulated scenes, allows testing of multiple, real illuminations. We use real scenes consisting of solid familiar or unfamiliar objects against uniform or variegated backgrounds and compare discrimination performance for typical illuminations from the daylight chromaticity locus (approximately blue-yellow) and atypical spectra from an orthogonal locus (approximately red-green, at correlated colour temperature 6700 K), all produced in real time by a 10-channel LED illuminator. We find that discrimination of illumination changes is poorer along the daylight locus than the atypical locus, and is poorest particularly for bluer illumination changes, demonstrating conversely that surface colour constancy is best for blue daylight illuminations. Illumination discrimination is also enhanced, and therefore colour constancy diminished, for uniform backgrounds, irrespective of the object type. These results are not explained by statistical properties of the scene signal changes at the retinal level. We conclude that high-level mechanisms of colour constancy are biased for the blue daylight illuminations and variegated backgrounds to which the human visual system has typically been exposed. PMID:24586299
Black light - How sensors filter spectral variation of the illuminant
NASA Technical Reports Server (NTRS)
Brainard, David H.; Wandell, Brian A.; Cowan, William B.
1989-01-01
Visual sensor responses may be used to classify objects on the basis of their surface reflectance functions. In a color image, the image data are represented as a vector of sensor responses at each point in the image. This vector depends both on the surface reflectance functions and on the spectral power distribution of the ambient illumination. Algorithms designed to classify objects on the basis of their surface reflectance functions typically attempt to overcome the dependence of the sensor responses on the illuminant by integrating sensor data collected from multiple surfaces. In machine vision applications, it is shown that it is often possible to design the sensor spectral responsivities so that the vector direction of the sensor responses does not depend upon the illuminant. The conditions under which this is possible are given and an illustrative calculation is performed. In biological systems, where the sensor responsivities are fixed, it is shown that some changes in the illumination cause no change in the sensor responses. Such changes in illuminant are called black illuminants. It is possible to express any illuminant as the sum of two unique components. One component is a black illuminant. The second component is called the visible component. The visible component of an illuminant completely characterizes the effect of the illuminant on the vector of sensor responses.
Internal-illumination photoacoustic computed tomography
NASA Astrophysics Data System (ADS)
Li, Mucong; Lan, Bangxin; Liu, Wei; Xia, Jun; Yao, Junjie
2018-03-01
We report a photoacoustic computed tomography (PACT) system using a customized optical fiber with a cylindrical diffuser to internally illuminate deep targets. The traditional external light illumination in PACT usually limits the penetration depth to a few centimeters from the tissue surface, mainly due to strong optical attenuation along the light propagation path from the outside in. By contrast, internal light illumination, with external ultrasound detection, can potentially detect much deeper targets. Different from previous internal illumination PACT implementations using forward-looking optical fibers, our internal-illumination PACT system uses a customized optical fiber with a 3-cm-long conoid needle diffuser attached to the fiber tip, which can homogeneously illuminate the surrounding space and substantially enlarge the field of view. We characterized the internal illumination distribution and PACT system performance. We performed tissue phantom and in vivo animal studies to further demonstrate the superior imaging depth using internal illumination over external illumination. We imaged a 7.5-cm-deep leaf target embedded in optically scattering medium and the beating heart of a mouse overlaid with 3.7-cm-thick chicken tissue. Our results have collectively demonstrated that the internal light illumination combined with external ultrasound detection might be a useful strategy to improve the penetration depth of PACT in imaging deep organs of large animals and humans.
Large Volume, Behaviorally-relevant Illumination for Optogenetics in Non-human Primates.
Acker, Leah C; Pino, Erica N; Boyden, Edward S; Desimone, Robert
2017-10-03
This protocol describes a large-volume illuminator, which was developed for optogenetic manipulations in the non-human primate brain. The illuminator is a modified plastic optical fiber with etched tip, such that the light emitting surface area is > 100x that of a conventional fiber. In addition to describing the construction of the large-volume illuminator, this protocol details the quality-control calibration used to ensure even light distribution. Further, this protocol describes techniques for inserting and removing the large volume illuminator. Both superficial and deep structures may be illuminated. This large volume illuminator does not need to be physically coupled to an electrode, and because the illuminator is made of plastic, not glass, it will simply bend in circumstances when traditional optical fibers would shatter. Because this illuminator delivers light over behaviorally-relevant tissue volumes (≈ 10 mm 3 ) with no greater penetration damage than a conventional optical fiber, it facilitates behavioral studies using optogenetics in non-human primates.
Illumination estimation via thin-plate spline interpolation.
Shi, Lilong; Xiong, Weihua; Funt, Brian
2011-05-01
Thin-plate spline interpolation is used to interpolate the chromaticity of the color of the incident scene illumination across a training set of images. Given the image of a scene under unknown illumination, the chromaticity of the scene illumination can be found from the interpolated function. The resulting illumination-estimation method can be used to provide color constancy under changing illumination conditions and automatic white balancing for digital cameras. A thin-plate spline interpolates over a nonuniformly sampled input space, which in this case is a training set of image thumbnails and associated illumination chromaticities. To reduce the size of the training set, incremental k medians are applied. Tests on real images demonstrate that the thin-plate spline method can estimate the color of the incident illumination quite accurately, and the proposed training set pruning significantly decreases the computation.
NASA Astrophysics Data System (ADS)
Amelard, Robert; Scharfenberger, Christian; Wong, Alexander; Clausi, David A.
2015-03-01
Non-contact camera-based imaging photoplethysmography (iPPG) is useful for measuring heart rate in conditions where contact devices are problematic due to issues such as mobility, comfort, and sanitation. Existing iPPG methods analyse the light-tissue interaction of either active or passive (ambient) illumination. Many active iPPG methods assume the incident ambient light is negligible to the active illumination, resulting in high power requirements, while many passive iPPG methods assume near-constant ambient conditions. These assumptions can only be achieved in environments with controlled illumination and thus constrain the use of such devices. To increase the number of possible applications of iPPG devices, we propose a dual-mode active iPPG system that is robust to changes in ambient illumination variations. Our system uses a temporally-coded illumination sequence that is synchronized with the camera to measure both active and ambient illumination interaction for determining heart rate. By subtracting the ambient contribution, the remaining illumination data can be attributed to the controlled illuminant. Our device comprises a camera and an LED illuminant controlled by a microcontroller. The microcontroller drives the temporal code via synchronizing the frame captures and illumination time at the hardware level. By simulating changes in ambient light conditions, experimental results show our device is able to assess heart rate accurately in challenging lighting conditions. By varying the temporal code, we demonstrate the trade-off between camera frame rate and ambient light compensation for optimal blood pulse detection.
Effect of Illumination on Ocular Status Modifications Induced by Short-Term 3D TV Viewing
Chen, Yuanyuan; Xu, Aiqin; Jiang, Jian
2017-01-01
Objectives. This study aimed to compare changes in ocular status after 3D TV viewing under three modes of illumination and thereby identify optimal illumination for 3D TV viewing. Methods. The following measures of ocular status were assessed: the accommodative response, accommodative microfluctuation, accommodative facility, relative accommodation, gradient accommodative convergence/accommodation (AC/A) ratio, phoria, and fusional vergence. The observers watched 3D television for 90 minutes through 3D shutter glasses under three illumination modes: A, complete darkness; B, back illumination (50 lx); and C, front illumination (130 lx). The ocular status of the observers was assessed both before and after the viewing. Results. After 3D TV viewing, the accommodative response and accommodative microfluctuation were significantly changed under illumination Modes A and B. The near positive fusional vergence decreased significantly after the 90-minute 3D viewing session under each illumination mode, and this effect was not significantly different among the three modes. Conclusions. Short-term 3D viewing modified the ocular status of adults. The least amount of such change occurred with front illumination, suggesting that this type of illumination is an appropriate mode for 3D shutter TV viewing. PMID:28348893
The relationship between ambient illumination and psychological factors in viewing of display Images
NASA Astrophysics Data System (ADS)
Iwanami, Takuya; Kikuchi, Ayano; Kaneko, Takashi; Hirai, Keita; Yano, Natsumi; Nakaguchi, Toshiya; Tsumura, Norimichi; Yoshida, Yasuhiro; Miyake, Yoichi
2009-01-01
In this paper, we have clarified the relationship between ambient illumination and psychological factors in viewing of display images. Psychological factors were obtained by the factor analysis with the results of the semantic differential (SD) method. In the psychological experiments, subjects evaluated the impressions of displayed images with changing ambient illuminating conditions. The illumination conditions were controlled by a fluorescent ceiling light and a color LED illumination which was located behind the display. We experimented under two kinds of conditions. One was the experiment with changing brightness of the ambient illumination. The other was the experiment with changing the colors of the background illumination. In the results of the experiment, two factors "realistic sensation, dynamism" and "comfortable," were extracted under different brightness of the ambient illumination of the display surroundings. It was shown that the "comfortable" was improved by the brightness of display surroundings. On the other hand, when the illumination color of surroundings was changed, three factors "comfortable," "realistic sensation, dynamism" and "activity" were extracted. It was also shown that the value of "comfortable" and "realistic sensation, dynamism" increased when the display surroundings were illuminated by the average color of the image contents.
Optimal color temperature adjustment for mobile devices under varying illuminants
NASA Astrophysics Data System (ADS)
Choi, Kyungah; Suk, Hyeon-Jeong
2014-01-01
With the wide use of mobile devices, display color reproduction has become extremely important. The purpose of this study is to investigate the optimal color temperature for mobile displays under varying illuminants. The effect of the color temperature and the illuminance of ambient lighting on user preferences were observed. For a visual examination, a total of 19 nuanced whites were examined under 20 illuminants. A total of 19 display stimuli with different color temperatures (2,500 K ~ 19,600 K) were presented on an iPad3 (New iPad). The ambient illuminants ranged in color temperature from 2,500 K to 19,800 K and from 0 lx to 3,000 lx in illuminance. Supporting previous studies of color reproduction, there was found to be a positive correlation between the color temperature of illuminants and that of optimal whites. However, the relationship was not linear. Based on assessments by 56 subjects, a regression equation was derived to predict the optimal color temperature adjustment under varying illuminants, as follows: [Display Tcp = 5138.93 log(Illuminant Tcp) - 11956.59, p<.001, R2=0.94]. Moreover, the influence of an illuminant was positively correlated with the illuminance level, confirming the findings of previous studies. It is expected that the findings of this study can be used as the theoretical basis when designing a color strategy for mobile display devices.
Diffraction analysis of customized illumination technique
NASA Astrophysics Data System (ADS)
Lim, Chang-Moon; Kim, Seo-Min; Eom, Tae-Seung; Moon, Seung Chan; Shin, Ki S.
2004-05-01
Various enhancement techniques such as alternating PSM, chrome-less phase lithography, double exposure, etc. have been considered as driving forces to lead the production k1 factor towards below 0.35. Among them, a layer specific optimization of illumination mode, so-called customized illumination technique receives deep attentions from lithographers recently. A new approach for illumination customization based on diffraction spectrum analysis is suggested in this paper. Illumination pupil is divided into various diffraction domains by comparing the similarity of the confined diffraction spectrum. Singular imaging property of individual diffraction domain makes it easier to build and understand the customized illumination shape. By comparing the goodness of image in each domain, it was possible to achieve the customized shape of illumination. With the help from this technique, it was found that the layout change would not gives the change in the shape of customized illumination mode.
User-preferred color temperature adjustment for smartphone display under varying illuminants
NASA Astrophysics Data System (ADS)
Choi, Kyungah; Suk, Hyeon-Jeong
2014-06-01
The study aims to investigate the user-preferred color temperature adjustment for smartphone displays by observing the effect of the illuminant's chromaticity and intensity on the optimal white points preferred by users. For visual examination, subjects evaluated 14 display stimuli presented on the Samsung Galaxy S3 under 19 ambient illuminants. The display stimuli were composed of 14 nuanced whites varying in color temperature from 2900 to 18,900 K. The illuminant conditions varied with combinations of color temperature (2600 to 20,100 K) and illuminance level (30 to 3100 lx) that simulated daily lighting experiences. The subjects were asked to assess the optimal level of the display color temperatures based on their mental representation of the ideal white point. The study observed a positive correlation between the illuminant color temperatures and the optimal display color temperatures (r=0.89, p<0.05). However, the range of the color temperature of the smartphone display was much narrower than that of the illuminants. Based on the assessments by 100 subjects, a regression formula was derived to predict the adjustment of user-preferred color temperature under changing illuminant chromaticity. The formula is as follows: [Display Tcp=6534.75 log (Illuminant Tcp)-16304.68 (R=0.87, p<0.05)]. Moreover, supporting previous studies on color reproduction, the effect of illuminant chromaticity was relatively weaker under lower illuminance. The results of this experiment could be used as a theoretical basis for designers and manufacturers to adjust user-preferred color temperature for smartphone displays under various illuminant conditions.
Lightness of an object under two illumination levels.
Zdravković, Suncica; Economou, Elias; Gilchrist, Alan
2006-01-01
Anchoring theory (Gilchrist et al, 1999 Psychological Review 106 795-834) predicts a wide range of lightness errors, including failures of constancy in multi-illumination scenes and a long list of well-known lightness illusions seen under homogeneous illumination. Lightness values are computed both locally and globally and then averaged together. Local values are computed within a given region of homogeneous illumination. Thus, for an object that extends through two different illumination levels, anchoring theory produces two values, one for the patch in brighter illumination and one for the patch in dimmer illumination. Observers can give matches for these patches separately, but they can also give a single match for the whole object. Anchoring theory in its current form is unable to predict these object matches. We report eight experiments in which we studied the relationship between patch matches and object matches. The results show that the object match represents a compromise between the match for the patch in the field of highest illumination and the patch in the largest field of illumination. These two principles are parallel to the rules found for anchoring lightness: highest luminance rule and area rule.
Micro-optics: enabling technology for illumination shaping in optical lithography
NASA Astrophysics Data System (ADS)
Voelkel, Reinhard
2014-03-01
Optical lithography has been the engine that has empowered semiconductor industry to continually reduce the half-pitch for over 50 years. In early mask aligners a simple movie lamp was enough to illuminate the photomask. Illumination started to play a more decisive role when proximity mask aligners appeared in the mid-1970s. Off-axis illumination was introduced to reduce diffraction effects. For early projection lithography systems (wafer steppers), the only challenge was to collect the light efficiently to ensure short exposure time. When projection optics reached highest level of perfection, further improvement was achieved by optimizing illumination. Shaping the illumination light, also referred as pupil shaping, allows the optical path from reticle to wafer to be optimized and thus has a major impact on aberrations and diffraction effects. Highly-efficient micro-optical components are perfectly suited for this task. Micro-optics for illumination evolved from simple flat-top (fly's-eye) to annular, dipole, quadrupole, multipole and freeform illumination. Today, programmable micro-mirror arrays allow illumination to be changed on the fly. The impact of refractive, diffractive and reflective microoptics for photolithography will be discussed.
Determinants of Colour Constancy and the Blue Bias
Gegenfurtner, Karl
2017-01-01
We investigated several sensory and cognitive determinants of colour constancy across 40 illumination hues. In the first experiment, we measured colour naming for the illumination and for the colour induced by the illumination on the colorimetric grey. Results confirmed that the induced colours are approximately complementary to the colour of the illumination. In the second experiment, we measured colour constancy using achromatic adjustments. Average colour constancy was perfect under the blue daylight illumination and decreased in colour directions away from the blue daylight illumination due to undershooting and a strong blue bias. Apart from this blue bias, colour constancy was not related to illumination discrimination and to chromatic detection measured previously with the same setup and stimuli. We also observed a strong negative relationship between the degree of colour constancy and the consensus of naming the illumination colour. Constancy coincided with a low naming consensus, in particular because bluish illumination colours were sometimes seen as achromatic. Blue bias and category consensus alone explained >68%, and all determinants together explained >94% of the variance of achromatic adjustments. These findings suggest that colour constancy is optimised for blue daylight. PMID:29348910
Adaptive non-local smoothing-based weberface for illumination-insensitive face recognition
NASA Astrophysics Data System (ADS)
Yao, Min; Zhu, Changming
2017-07-01
Compensating the illumination of a face image is an important process to achieve effective face recognition under severe illumination conditions. This paper present a novel illumination normalization method which specifically considers removing the illumination boundaries as well as reducing the regional illumination. We begin with the analysis of the commonly used reflectance model and then expatiate the hybrid usage of adaptive non-local smoothing and the local information coding based on Weber's law. The effectiveness and advantages of this combination are evidenced visually and experimentally. Results on Extended YaleB database show its better performance than several other famous methods.
Santos, Silvia; Chu, Kengyeh K; Lim, Daryl; Bozinovic, Nenad; Ford, Tim N; Hourtoule, Claire; Bartoo, Aaron C; Singh, Satish K; Mertz, Jerome
2009-01-01
We present an endomicroscope apparatus that exhibits out-of-focus background rejection based on wide-field illumination through a flexible imaging fiber bundle. Our technique, called HiLo microscopy, involves acquiring two images, one with grid-pattern illumination and another with standard uniform illumination. An evaluation of the image contrast with grid-pattern illumination provides an optically sectioned image with low resolution. This is complemented with high-resolution information from the uniform illumination image, leading to a full-resolution image that is optically sectioned. HiLo endomicroscope movies are presented of fluorescently labeled rat colonic mucosa.
NASA Astrophysics Data System (ADS)
Santos, Silvia; Chu, Kengyeh K.; Lim, Daryl; Bozinovic, Nenad; Ford, Tim N.; Hourtoule, Claire; Bartoo, Aaron C.; Singh, Satish K.; Mertz, Jerome
2009-05-01
We present an endomicroscope apparatus that exhibits out-of-focus background rejection based on wide-field illumination through a flexible imaging fiber bundle. Our technique, called HiLo microscopy, involves acquiring two images, one with grid-pattern illumination and another with standard uniform illumination. An evaluation of the image contrast with grid-pattern illumination provides an optically sectioned image with low resolution. This is complemented with high-resolution information from the uniform illumination image, leading to a full-resolution image that is optically sectioned. HiLo endomicroscope movies are presented of fluorescently labeled rat colonic mucosa.
Illumination discrimination in real and simulated scenes
Radonjić, Ana; Pearce, Bradley; Aston, Stacey; Krieger, Avery; Dubin, Hilary; Cottaris, Nicolas P.; Brainard, David H.; Hurlbert, Anya C.
2016-01-01
Characterizing humans' ability to discriminate changes in illumination provides information about the visual system's representation of the distal stimulus. We have previously shown that humans are able to discriminate illumination changes and that sensitivity to such changes depends on their chromatic direction. Probing illumination discrimination further would be facilitated by the use of computer-graphics simulations, which would, in practice, enable a wider range of stimulus manipulations. There is no a priori guarantee, however, that results obtained with simulated scenes generalize to real illuminated scenes. To investigate this question, we measured illumination discrimination in real and simulated scenes that were well-matched in mean chromaticity and scene geometry. Illumination discrimination thresholds were essentially identical for the two stimulus types. As in our previous work, these thresholds varied with illumination change direction. We exploited the flexibility offered by the use of graphics simulations to investigate whether the differences across direction are preserved when the surfaces in the scene are varied. We show that varying the scene's surface ensemble in a manner that also changes mean scene chromaticity modulates the relative sensitivity to illumination changes along different chromatic directions. Thus, any characterization of sensitivity to changes in illumination must be defined relative to the set of surfaces in the scene. PMID:28558392
An intraocular micro light-emitting diode device for endo-illumination during pars plana vitrectomy.
Koelbl, Philipp S; Lingenfelder, Christian; Spraul, Christoph W; Kampmeier, Juergen; Koch, Frank Hj; Kim, Yong Keun; Hessling, Martin
2018-03-01
Development of a new, fiber-free, single-use endo-illuminator for pars plana vitrectomy as a replacement for fiber-based systems with external light sources. The hand-guided intraocularly placed white micro light-emitting diode is evaluated for its illumination properties and potential photochemical and thermal hazards. A micro light-emitting diode was used to develop a single-use intraocular illumination system. The light-source-on-tip device was implemented in a prototype with 23G trocar compatible outer diameter of 0.6 mm. The experimental testing was performed on porcine eyes. All calculations of possible photochemical and thermal hazards during the application of the intraocular micro light-emitting diode were calculated according to DIN EN ISO 15007-2: 2014. The endo-illuminator generated a homogeneous and bright illumination of the intraocular space. The color impression was physiologic and natural. Contrary to initial apprehension, the possible risk caused by inserting a light-emitting diode into the intraocular vitreous was much smaller when compared to conventional fiber-based illumination systems. The photochemical and thermal hazards allowed a continuous exposure time to the retina of at least 4.7 h. This first intraocular light source showed that a light-emitting diode can be introduced into the eye. The system can be built as single-use illumination system. This light-source-on-tip light-emitting diode-endo-illumination combines a chandelier wide-angle illumination with an adjustable endo-illuminator.
Wide-field fundus imaging with trans-palpebral illumination.
Toslak, Devrim; Thapa, Damber; Chen, Yanjun; Erol, Muhammet Kazim; Paul Chan, R V; Yao, Xincheng
2017-01-28
In conventional fundus imaging devices, transpupillary illumination is used for illuminating the inside of the eye. In this method, the illumination light is directed into the posterior segment of the eye through the cornea and passes the pupillary area. As a result of sharing the pupillary area for the illumination beam and observation path, pupil dilation is typically necessary for wide-angle fundus examination, and the field of view is inherently limited. An alternative approach is to deliver light from the sclera. It is possible to image a wider retinal area with transcleral-illumination. However, the requirement of physical contact between the illumination probe and the sclera is a drawback of this method. We report here trans-palpebral illumination as a new method to deliver the light through the upper eyelid (palpebra). For this study, we used a 1.5 mm diameter fiber with a warm white LED light source. To illuminate the inside of the eye, the fiber illuminator was placed at the location corresponding to the pars plana region. A custom designed optical system was attached to a digital camera for retinal imaging. The optical system contained a 90 diopter ophthalmic lens and a 25 diopter relay lens. The ophthalmic lens collected light coming from the posterior of the eye and formed an aerial image between the ophthalmic and relay lenses. The aerial image was captured by the camera through the relay lens. An adequate illumination level was obtained to capture wide angle fundus images within ocular safety limits, defined by the ISO 15004-2: 2007 standard. This novel trans-palpebral illumination approach enables wide-angle fundus photography without eyeball contact and pupil dilation.
21 CFR 892.1890 - Radiographic film illuminator.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Radiographic film illuminator. 892.1890 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1890 Radiographic film illuminator. (a) Identification. A radiographic film illuminator is a device containing a visible light source covered with a...
21 CFR 892.1890 - Radiographic film illuminator.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Radiographic film illuminator. 892.1890 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1890 Radiographic film illuminator. (a) Identification. A radiographic film illuminator is a device containing a visible light source covered with a...
21 CFR 892.1890 - Radiographic film illuminator.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Radiographic film illuminator. 892.1890 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1890 Radiographic film illuminator. (a) Identification. A radiographic film illuminator is a device containing a visible light source covered with a...
21 CFR 892.1890 - Radiographic film illuminator.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Radiographic film illuminator. 892.1890 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1890 Radiographic film illuminator. (a) Identification. A radiographic film illuminator is a device containing a visible light source covered with a...
21 CFR 892.1890 - Radiographic film illuminator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film illuminator. 892.1890 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1890 Radiographic film illuminator. (a) Identification. A radiographic film illuminator is a device containing a visible light source covered with a...
32 CFR 707.10 - Wake illumination light.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 32 National Defense 5 2013-07-01 2013-07-01 false Wake illumination light. 707.10 Section 707.10... RESPECT TO ADDITIONAL STATION AND SIGNAL LIGHTS § 707.10 Wake illumination light. Naval vessels may display a white spot light located near the stern to illuminate the wake. ...
32 CFR 707.10 - Wake illumination light.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 32 National Defense 5 2014-07-01 2014-07-01 false Wake illumination light. 707.10 Section 707.10... RESPECT TO ADDITIONAL STATION AND SIGNAL LIGHTS § 707.10 Wake illumination light. Naval vessels may display a white spot light located near the stern to illuminate the wake. ...
32 CFR 707.10 - Wake illumination light.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 32 National Defense 5 2011-07-01 2011-07-01 false Wake illumination light. 707.10 Section 707.10... RESPECT TO ADDITIONAL STATION AND SIGNAL LIGHTS § 707.10 Wake illumination light. Naval vessels may display a white spot light located near the stern to illuminate the wake. ...
32 CFR 707.10 - Wake illumination light.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 32 National Defense 5 2012-07-01 2012-07-01 false Wake illumination light. 707.10 Section 707.10... RESPECT TO ADDITIONAL STATION AND SIGNAL LIGHTS § 707.10 Wake illumination light. Naval vessels may display a white spot light located near the stern to illuminate the wake. ...
Wagner, Ines; Steinweg, Christian; Posten, Clemens
2016-08-01
Illumination with red and blue photons is known to be efficient for cultivation of higher plants. For microalgae cultivation, illumination with specific wavelengths rather than full spectrum illumination can be an alternative where there is a lack of knowledge about achievable biomass yields. This study deals with the usage of color LED illumination to cultivate microalgae integrated into closed life support systems for outer space. The goal is to quantify biomass yields using color illumination (red, blue, green and mixtures) compared to white light. Chlamydomonas reinhardtii was cultivated in plate reactors with color compared to white illumination regarding PCE, specific pigment concentration and cell size. Highest PCE values were achieved under low PFDs with a red/blue illumination (680 nm/447 nm) at a 90 to 10% molar ratio. At higher PFDs saturation effects can be observed resulting from light absorption characteristics and the linear part of PI curve. Cell size and aggregation are also influenced by the applied light color. Red/blue color illumination is a promising option applicable for microalgae-based modules of life support systems under low to saturating light intensities and double-sided illumination. Results of higher PCE with addition of blue photons to red light indicate an influence of sensory pigments. Copyright © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zahiruddin, Kowser; Banu, Shaj; Dharmarajan, Ramya; Kulothungan, Vaitheeswaran; Vijayan, Deepa; Raman, Rajiv; Sharma, Tarun
2010-06-01
To evaluate a customized, portable Farnsworth-Munsell 100 (FM 100) hue viewing booth for compliance with colour vision testing standards and to compare it with room illumination in subjects with normal colour vision (trichromats), subjects with acquired colour vision defects (secondary to diabetes mellitus), and subjects with congenital colour vision defects (dichromats). Discrete wavelengths of the tube in the customized booth were measured using a spectrometer using the normal incident method and were compared with the spectral distribution of sunlight. Forty-eight subjects were recruited for the study and were divided into 3 groups: Group 1, Normal Trichromats (30 eyes); Group 2, Congenital Colour Vision Defects (16 eyes); and Group 3, Diabetes Mellitus (20 eyes). The FM 100 hue test performance was compared using two illumination conditions, booth illumination and room illumination. Total error scores of the classical method in Group 2 as mean+/-SD for room and booth illumination was 243.05+/-85.96 and 149.85+/-54.50 respectively (p=0.0001). Group 2 demonstrated lesser correlation (r=0.50, 0.55), lesser reliability (Cronbach's alpha, 0.625, 0.662) and greater variability (Bland & Altman value, 10.5) in total error scores for the classical method and the moment of inertia method between the two illumination conditions when compared to the other two groups. The customized booth demonstrated illumination meeting CIE standards. The total error scores were overestimated by the classical and moment of inertia methods in all groups for room illumination compared with booth illumination, however overestimation was more significant in the diabetes group.
21 CFR 886.1160 - Color vision plate illuminator.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Color vision plate illuminator. 886.1160 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1160 Color vision plate illuminator. (a) Identification. A color vision plate illuminator is an AC-powered device that is a lamp intended...
21 CFR 886.1160 - Color vision plate illuminator.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Color vision plate illuminator. 886.1160 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1160 Color vision plate illuminator. (a) Identification. A color vision plate illuminator is an AC-powered device that is a lamp intended...
21 CFR 886.1160 - Color vision plate illuminator.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Color vision plate illuminator. 886.1160 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1160 Color vision plate illuminator. (a) Identification. A color vision plate illuminator is an AC-powered device that is a lamp intended...
Manufacturing Methods and Technology Program Automatic In-Process Microcircuit Evaluation.
1978-09-01
illumination system consists of an illuminati on controlle r , three illumination power- supplies , and three illuminator housings . The illumination... illuminati on level. - - The main power (115 V , 60 Hz) for the power-supplies is derived from the power distribu- tion panel. There are two switches In the
21 CFR 886.1160 - Color vision plate illuminator.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Color vision plate illuminator. 886.1160 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1160 Color vision plate illuminator. (a) Identification. A color vision plate illuminator is an AC-powered device that is a lamp intended...
21 CFR 886.1160 - Color vision plate illuminator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Color vision plate illuminator. 886.1160 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1160 Color vision plate illuminator. (a) Identification. A color vision plate illuminator is an AC-powered device that is a lamp intended...
Flinkman, Mika; Nakauchi, Shigeki
2017-10-01
In this research, three illuminants that improve color discrimination ability of people with red-green color vision deficiency were developed. The illuminants are close to daylight-colored and were produced by using spectral optimization. Deutans were the focus of this research, but a few protans were also tested for reference. The illuminants were produced by combining different types of LEDs, and their effects were tested with several test subjects with and without color vision deficiency using the Ishihara color vision test and the Farnsworth Panel D-15 test. The illuminant with the most powerful effect provided near perfect results with the Ishihara test for deutans, while the other two illuminants produced smaller improvements. The Farnsworth Panel D-15 test produced results that were similar to the Ishihara test though generally the color discrimination of blue hues was weaker under the most powerful illuminant.
Reduction of background clutter in structured lighting systems
Carlson, Jeffrey J.; Giles, Michael K.; Padilla, Denise D.; Davidson, Jr., Patrick A.; Novick, David K.; Wilson, Christopher W.
2010-06-22
Methods for segmenting the reflected light of an illumination source having a characteristic wavelength from background illumination (i.e. clutter) in structured lighting systems can comprise pulsing the light source used to illuminate a scene, pulsing the light source synchronously with the opening of a shutter in an imaging device, estimating the contribution of background clutter by interpolation of images of the scene collected at multiple spectral bands not including the characteristic wavelength and subtracting the estimated background contribution from an image of the scene comprising the wavelength of the light source and, placing a polarizing filter between the imaging device and the scene, where the illumination source can be polarized in the same orientation as the polarizing filter. Apparatus for segmenting the light of an illumination source from background illumination can comprise an illuminator, an image receiver for receiving images of multiple spectral bands, a processor for calculations and interpolations, and a polarizing filter.
Sohn, Martin Y; Barnes, Bryan M; Silver, Richard M
2018-03-01
Accurate optics-based dimensional measurements of features sized well-below the diffraction limit require a thorough understanding of the illumination within the optical column and of the three-dimensional scattered fields that contain the information required for quantitative metrology. Scatterfield microscopy can pair simulations with angle-resolved tool characterization to improve agreement between the experiment and calculated libraries, yielding sub-nanometer parametric uncertainties. Optimized angle-resolved illumination requires bi-telecentric optics in which a telecentric sample plane defined by a Köhler illumination configuration and a telecentric conjugate back focal plane (CBFP) of the objective lens; scanning an aperture or an aperture source at the CBFP allows control of the illumination beam angle at the sample plane with minimal distortion. A bi-telecentric illumination optics have been designed enabling angle-resolved illumination for both aperture and source scanning modes while yielding low distortion and chief ray parallelism. The optimized design features a maximum chief ray angle at the CBFP of 0.002° and maximum wavefront deviations of less than 0.06 λ for angle-resolved illumination beams at the sample plane, holding promise for high quality angle-resolved illumination for improved measurements of deep-subwavelength structures using deep-ultraviolet light.
NASA Astrophysics Data System (ADS)
Yu, You; Han, Yanchao; Xu, Miao; Zhang, Lingling; Dong, Shaojun
2016-04-01
Inverted illumination compensation is important in energy-saving projects, artificial photosynthesis and some forms of agriculture, such as hydroponics. However, only a few illumination adjustments based on self-powered biodetectors that quantitatively detect the intensity of visible light have been reported. We constructed an automatic illumination compensation device based on a photoelectrochemical biofuel cell (PBFC) driven by visible light. The PBFC consisted of a glucose dehydrogenase modified bioanode and a p-type semiconductor cuprous oxide photocathode. The PBFC had a high power output of 161.4 μW cm-2 and an open circuit potential that responded rapidly to visible light. It adjusted the amount of illumination inversely irrespective of how the external illumination was changed. This rational design of utilizing PBFCs provides new insights into automatic light adjustable devices and may be of benefit to intelligent applications.Inverted illumination compensation is important in energy-saving projects, artificial photosynthesis and some forms of agriculture, such as hydroponics. However, only a few illumination adjustments based on self-powered biodetectors that quantitatively detect the intensity of visible light have been reported. We constructed an automatic illumination compensation device based on a photoelectrochemical biofuel cell (PBFC) driven by visible light. The PBFC consisted of a glucose dehydrogenase modified bioanode and a p-type semiconductor cuprous oxide photocathode. The PBFC had a high power output of 161.4 μW cm-2 and an open circuit potential that responded rapidly to visible light. It adjusted the amount of illumination inversely irrespective of how the external illumination was changed. This rational design of utilizing PBFCs provides new insights into automatic light adjustable devices and may be of benefit to intelligent applications. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr00759g
Energy efficient LED layout optimization for near-uniform illumination
NASA Astrophysics Data System (ADS)
Ali, Ramy E.; Elgala, Hany
2016-09-01
In this paper, we consider the problem of designing energy efficient light emitting diodes (LEDs) layout while satisfying the illumination constraints. Towards this objective, we present a simple approach to the illumination design problem based on the concept of the virtual LED. We formulate a constrained optimization problem for minimizing the power consumption while maintaining a near-uniform illumination throughout the room. By solving the resulting constrained linear program, we obtain the number of required LEDs and the optimal output luminous intensities that achieve the desired illumination constraints.
Enhanced facial texture illumination normalization for face recognition.
Luo, Yong; Guan, Ye-Peng
2015-08-01
An uncontrolled lighting condition is one of the most critical challenges for practical face recognition applications. An enhanced facial texture illumination normalization method is put forward to resolve this challenge. An adaptive relighting algorithm is developed to improve the brightness uniformity of face images. Facial texture is extracted by using an illumination estimation difference algorithm. An anisotropic histogram-stretching algorithm is proposed to minimize the intraclass distance of facial skin and maximize the dynamic range of facial texture distribution. Compared with the existing methods, the proposed method can more effectively eliminate the redundant information of facial skin and illumination. Extensive experiments show that the proposed method has superior performance in normalizing illumination variation and enhancing facial texture features for illumination-insensitive face recognition.
Comparison of two structured illumination techniques based on different 3D illumination patterns
NASA Astrophysics Data System (ADS)
Shabani, H.; Patwary, N.; Doblas, A.; Saavedra, G.; Preza, C.
2017-02-01
Manipulating the excitation pattern in optical microscopy has led to several super-resolution techniques. Among different patterns, the lateral sinusoidal excitation was used for the first demonstration of structured illumination microscopy (SIM), which provides the fastest SIM acquisition system (based on the number of raw images required) compared to the multi-spot illumination approach. Moreover, 3D patterns that include lateral and axial variations in the illumination have attracted more attention recently as they address resolution enhancement in three dimensions. A threewave (3W) interference technique based on coherent illumination has already been shown to provide super-resolution and optical sectioning in 3D-SIM. In this paper, we investigate a novel tunable technique that creates a 3D pattern from a set of multiple incoherently illuminated parallel slits that act as light sources for a Fresnel biprism. This setup is able to modulate the illumination pattern in the object space both axially and laterally with adjustable modulation frequencies. The 3D forward model for the new system is developed here to consider the effect of the axial modulation due to the 3D patterned illumination. The performance of 3D-SIM based on 3W interference and the tunable system are investigated in simulation and compared based on two different criteria. First, restored images obtained for both 3D-SIM systems using a generalized Wiener filter are compared to determine the effect of the illumination pattern on the reconstruction. Second, the effective frequency response of both systems is studied to determine the axial and lateral resolution enhancement that is obtained in each case.
What #theDress reveals about the role of illumination priors in color perception and color constancy
Aston, Stacey; Hurlbert, Anya
2018-01-01
The disagreement between people who named #theDress (the Internet phenomenon of 2015) “blue and black” versus “white and gold” is thought to be caused by individual differences in color constancy. It is hypothesized that observers infer different incident illuminations, relying on illumination “priors” to overcome the ambiguity of the image. Different experiences may drive the formation of different illumination priors, and these may be indicated by differences in chronotype. We assess this hypothesis, asking whether matches to perceived illumination in the image and/or perceived dress colors relate to scores on the morningness-eveningness questionnaire (a measure of chronotype). We find moderate correlations between chronotype and illumination matches (morning types giving bluer illumination matches than evening types) and chronotype and dress body matches, but these are significant only at the 10% level. Further, although inferred illumination chromaticity in the image explains variation in the color matches to the dress (confirming the color constancy hypothesis), color constancy thresholds obtained using an established illumination discrimination task are not related to dress color perception. We also find achromatic settings depend on luminance, suggesting that subjective white point differences may explain the variation in dress color perception only if settings are made at individually tailored luminance levels. The results of such achromatic settings are inconsistent with their assumed correspondence to perceived illumination. Finally, our results suggest that perception and naming are disconnected, with observers reporting different color names for the dress photograph and their isolated color matches, the latter best capturing the variation in the matches. PMID:28793353
Miniature self-contained vacuum compatible electronic imaging microscope
Naulleau, Patrick P.; Batson, Phillip J.; Denham, Paul E.; Jones, Michael S.
2001-01-01
A vacuum compatible CCD-based microscopic camera with an integrated illuminator. The camera can provide video or still feed from the microscope contained within a vacuum chamber. Activation of an optional integral illuminator can provide light to illuminate the microscope subject. The microscope camera comprises a housing with a objective port, modified objective, beam-splitter, CCD camera, and LED illuminator.
Xu, Yilei; Roy-Chowdhury, Amit K
2007-05-01
In this paper, we present a theory for combining the effects of motion, illumination, 3D structure, albedo, and camera parameters in a sequence of images obtained by a perspective camera. We show that the set of all Lambertian reflectance functions of a moving object, at any position, illuminated by arbitrarily distant light sources, lies "close" to a bilinear subspace consisting of nine illumination variables and six motion variables. This result implies that, given an arbitrary video sequence, it is possible to recover the 3D structure, motion, and illumination conditions simultaneously using the bilinear subspace formulation. The derivation builds upon existing work on linear subspace representations of reflectance by generalizing it to moving objects. Lighting can change slowly or suddenly, locally or globally, and can originate from a combination of point and extended sources. We experimentally compare the results of our theory with ground truth data and also provide results on real data by using video sequences of a 3D face and the entire human body with various combinations of motion and illumination directions. We also show results of our theory in estimating 3D motion and illumination model parameters from a video sequence.
Real-time global illumination on mobile device
NASA Astrophysics Data System (ADS)
Ahn, Minsu; Ha, Inwoo; Lee, Hyong-Euk; Kim, James D. K.
2014-02-01
We propose a novel method for real-time global illumination on mobile devices. Our approach is based on instant radiosity, which uses a sequence of virtual point lights in order to represent the e ect of indirect illumination. Our rendering process consists of three stages. With the primary light, the rst stage generates a local illumination with the shadow map on GPU The second stage of the global illumination uses the re ective shadow map on GPU and generates the sequence of virtual point lights on CPU. Finally, we use the splatting method of Dachsbacher et al 1 and add the indirect illumination to the local illumination on GPU. With the limited computing resources in mobile devices, a small number of virtual point lights are allowed for real-time rendering. Our approach uses the multi-resolution sampling method with 3D geometry and attributes simultaneously and reduce the total number of virtual point lights. We also use the hybrid strategy, which collaboratively combines the CPUs and GPUs available in a mobile SoC due to the limited computing resources in mobile devices. Experimental results demonstrate the global illumination performance of the proposed method.
Side-emitting illuminators using LED sources
NASA Astrophysics Data System (ADS)
Zhao, Feng; Van Derlofske, John F.
2003-11-01
This study investigates illuminators composed of light emitting diode (LED) array sources and side-emitting light guides to provide efficient general illumination. Specifically, new geometries are explored to increase the efficiency of current systems while maintaining desired light distribution. LED technology is already successfully applied in many illumination applications, such as traffic signals and liquid crystal display (LCD) backlighting. It provides energy-efficient, small-package, long-life, and color-adjustable illumination. However, the use of LEDs in general illumination is still in its early stages. Current side-emitting systems typically use a light guide with light sources at one end, an end-cap surface at the other end, and light releasing sidewalls. This geometry introduces efficiency loss that can be as high as 40%. The illuminators analyzed in this study use LED array sources along the longitude of a light guide to increase the system efficiency. These new geometries also provide the freedom of elongating the system without sacrificing system efficiency. In addition, alternative geometries can be used to create white light with monochromatic LED sources. As concluded by this study, the side-emitting illuminators using LED sources gives the possibility of an efficient, distribution-controllable linear lighting system.
Microscopy illumination engineering using a low-cost liquid crystal display.
Guo, Kaikai; Bian, Zichao; Dong, Siyuan; Nanda, Pariksheet; Wang, Ying Min; Zheng, Guoan
2015-02-01
Illumination engineering is critical for obtaining high-resolution, high-quality images in microscope settings. In a typical microscope, the condenser lens provides sample illumination that is uniform and free from glare. The associated condenser diaphragm can be manually adjusted to obtain the optimal illumination numerical aperture. In this paper, we report a programmable condenser lens for active illumination control. In our prototype setup, we used a $15 liquid crystal display as a transparent spatial light modulator and placed it at the back focal plane of the condenser lens. By setting different binary patterns on the display, we can actively control the illumination and the spatial coherence of the microscope platform. We demonstrated the use of such a simple scheme for multimodal imaging, including bright-field microscopy, darkfield microscopy, phase-contrast microscopy, polarization microscopy, 3D tomographic imaging, and super-resolution Fourier ptychographic imaging. The reported illumination engineering scheme is cost-effective and compatible with most existing platforms. It enables a turnkey solution with high flexibility for researchers in various communities. From the engineering point-of-view, the reported illumination scheme may also provide new insights for the development of multimodal microscopy and Fourier ptychographic imaging.
The importance of illumination in nest site choice and nest characteristics of cavity nesting birds.
Podkowa, Paweł; Surmacki, Adrian
2017-05-02
Light has a significant impact on many aspects of avian biology, physiology and behaviour. An increasing number of studies show that illumination may positively influences birds' offspring fitness by e.g. acceleration of embryo development, stimulation of skeleton growth or regulation of circadian rhythm. Because nest cavities have especially low illumination, suitable light levels may be especially important for species which nest there. We may therefore expect that birds breeding in relatively dim conditions should prefer brighter nest sites and/or evolve behavioral mechanisms to secure sufficient light levels in the nest. Using nest boxes with modified internal illumination, we experimentally tested whether light regime is a cue for nest site selection of secondary cavity-nesting species. Additionally, we investigated whether nest building strategies are tuned to internal illumination. Our results demonstrate that, nest boxes with elevated illumination were chosen twice as often as dark nest boxes. Moreover, birds built higher nests in dark nest boxes than birds in boxes with elevated illumination, which suggests a mechanism of compensating for low light conditions. Our results provide the first experimental support for the idea that nest site choice and nest building behaviour in cavity-nesting birds are influenced by ambient illumination.
Multiple Illuminant Colour Estimation via Statistical Inference on Factor Graphs.
Mutimbu, Lawrence; Robles-Kelly, Antonio
2016-08-31
This paper presents a method to recover a spatially varying illuminant colour estimate from scenes lit by multiple light sources. Starting with the image formation process, we formulate the illuminant recovery problem in a statistically datadriven setting. To do this, we use a factor graph defined across the scale space of the input image. In the graph, we utilise a set of illuminant prototypes computed using a data driven approach. As a result, our method delivers a pixelwise illuminant colour estimate being devoid of libraries or user input. The use of a factor graph also allows for the illuminant estimates to be recovered making use of a maximum a posteriori (MAP) inference process. Moreover, we compute the probability marginals by performing a Delaunay triangulation on our factor graph. We illustrate the utility of our method for pixelwise illuminant colour recovery on widely available datasets and compare against a number of alternatives. We also show sample colour correction results on real-world images.
Oonincx, D G A B; Volk, N; Diehl, J J E; van Loon, J J A; Belušič, G
2016-12-01
Mating in the black soldier fly (BSF) is a visually mediated behaviour that under natural conditions occurs in full sunlight. Artificial light conditions promoting mating by BSF were designed based on the spectral characteristics of the compound eye retina. Electrophysiological measurements revealed that BSF ommatidia contained UV-, blue- and green-sensitive photoreceptor cells, allowing trichromatic vision. An illumination system for indoor breeding based on UV, blue and green LEDs was designed and its efficiency was compared with illumination by fluorescent tubes which have been successfully used to sustain a BSF colony for five years. Illumination by LEDs and the fluorescent tubes yielded equal numbers of egg clutches, however, the LED illumination resulted in significantly more larvae. The possibilities to optimize the current LED illumination system to better approximate the skylight illuminant and potentially optimize the larval yield are discussed. Copyright © 2016 Elsevier Ltd. All rights reserved.
Content-based fused off-axis object illumination direct-to-digital holography
Price, Jeffery R.
2006-05-02
Systems and methods are described for content-based fused off-axis illumination direct-to-digital holography. A method includes calculating an illumination angle with respect to an optical axis defined by a focusing lens as a function of data representing a Fourier analyzed spatially heterodyne hologram; reflecting a reference beam from a reference mirror at a non-normal angle; reflecting an object beam from an object the object beam incident upon the object at the illumination angle; focusing the reference beam and the object beam at a focal plane of a digital recorder to from the content-based off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis; and digitally recording the content based off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mielenz, K.D.; Hsia, J.J.
1990-01-01
The differences between ITS-90 and IPTS-68 (International Practical Temperature Scale of 1968) above 1235 K are described. It is shown that none of the following CIE (Commission Internationale de l'Eclairage or International Commission on Illumination) definitions or recommendations require revision because of the introduction of the ITS-90: International Lighting Vocabulary definitions; CIE Standard Illuminants A, D(65), other illuminants; and sources for realizing CIE Illuminants. The effect of the ITS-90 on previously calibrated sources for realizing CIE illuminants is negligibly small.
Kim, Min-Jeong; Yuk, Hyun-Gyun
2017-03-01
The aim of this study was to elucidate the antibacterial mechanism of 405 ± 5-nm light-emitting diode (LED) illumination against Salmonella at 4°C in phosphate-buffered saline (PBS) by determining endogenous coproporphyrin content, DNA oxidation, damage to membrane function, and morphological change. Gene expression levels, including of oxyR , recA , rpoS , sodA , and soxR , were also examined to understand the response of Salmonella to LED illumination. The results showed that Salmonella strains responded differently to LED illumination, revealing that S. enterica serovar Enteritidis (ATCC 13076) and S. enterica subsp. enterica serovar Saintpaul (ATCC 9712) were more susceptible and resistant, respectively, than the 16 other strains tested. There was no difference in the amounts of endogenous coproporphyrin in the two strains. Compared with that in nonilluminated cells, the DNA oxidation levels in illuminated cells increased. In illuminated cells, we observed a loss of efflux pump activity, damage to the glucose uptake system, and changes in membrane potential and integrity. Transmission electron microscopy revealed a disorganization of chromosomes and ribosomes due to LED illumination. The levels of the five genes measured in the nonilluminated and illuminated S Saintpaul cells were upregulated in PBS at a set temperature of 4°C, indicating that increased gene expression levels might be due to a temperature shift and nutrient deficiency rather than to LED illumination. In contrast, only oxyR in S Enteritidis cells was upregulated. Thus, different sensitivities of the two strains to LED illumination were attributed to differences in gene regulation. IMPORTANCE Bacterial inactivation using visible light has recently received attention as a safe and environmentally friendly technology, in contrast with UV light, which has detrimental effects on human health and the environment. This study was designed to understand how 405 ± 5-nm light-emitting diode (LED) illumination kills Salmonella strains at refrigeration temperature. The data clearly demonstrated that the effectiveness of LED illumination on Salmonella strains depended highly on the serotype and strain. Our findings also revealed that its antibacterial mechanism was mainly attributed to DNA oxidation and a loss of membrane functions rather than membrane lipid peroxidation, which has been proposed by other researchers who studied the antibacterial effect of LED illumination by adding exogenous photosensitizers, such as chlorophyllin and hypericin. Therefore, this study suggests that the detailed antibacterial mechanisms of 405-nm LED illumination without additional photosensitizers may differ from that by exogenous photosensitizers. Furthermore, a change in stress-related gene regulation may alter the susceptibility of Salmonella cells to LED illumination at refrigeration temperature. Thus, our study provides new insights into the antibacterial mechanism of 405 ± 5-nm LED illumination on Salmonella cells. Copyright © 2017 American Society for Microbiology.
Kim, Min-Jeong
2016-01-01
ABSTRACT The aim of this study was to elucidate the antibacterial mechanism of 405 ± 5-nm light-emitting diode (LED) illumination against Salmonella at 4°C in phosphate-buffered saline (PBS) by determining endogenous coproporphyrin content, DNA oxidation, damage to membrane function, and morphological change. Gene expression levels, including of oxyR, recA, rpoS, sodA, and soxR, were also examined to understand the response of Salmonella to LED illumination. The results showed that Salmonella strains responded differently to LED illumination, revealing that S. enterica serovar Enteritidis (ATCC 13076) and S. enterica subsp. enterica serovar Saintpaul (ATCC 9712) were more susceptible and resistant, respectively, than the 16 other strains tested. There was no difference in the amounts of endogenous coproporphyrin in the two strains. Compared with that in nonilluminated cells, the DNA oxidation levels in illuminated cells increased. In illuminated cells, we observed a loss of efflux pump activity, damage to the glucose uptake system, and changes in membrane potential and integrity. Transmission electron microscopy revealed a disorganization of chromosomes and ribosomes due to LED illumination. The levels of the five genes measured in the nonilluminated and illuminated S. Saintpaul cells were upregulated in PBS at a set temperature of 4°C, indicating that increased gene expression levels might be due to a temperature shift and nutrient deficiency rather than to LED illumination. In contrast, only oxyR in S. Enteritidis cells was upregulated. Thus, different sensitivities of the two strains to LED illumination were attributed to differences in gene regulation. IMPORTANCE Bacterial inactivation using visible light has recently received attention as a safe and environmentally friendly technology, in contrast with UV light, which has detrimental effects on human health and the environment. This study was designed to understand how 405 ± 5-nm light-emitting diode (LED) illumination kills Salmonella strains at refrigeration temperature. The data clearly demonstrated that the effectiveness of LED illumination on Salmonella strains depended highly on the serotype and strain. Our findings also revealed that its antibacterial mechanism was mainly attributed to DNA oxidation and a loss of membrane functions rather than membrane lipid peroxidation, which has been proposed by other researchers who studied the antibacterial effect of LED illumination by adding exogenous photosensitizers, such as chlorophyllin and hypericin. Therefore, this study suggests that the detailed antibacterial mechanisms of 405-nm LED illumination without additional photosensitizers may differ from that by exogenous photosensitizers. Furthermore, a change in stress-related gene regulation may alter the susceptibility of Salmonella cells to LED illumination at refrigeration temperature. Thus, our study provides new insights into the antibacterial mechanism of 405 ± 5-nm LED illumination on Salmonella cells. PMID:28003197
NASA Astrophysics Data System (ADS)
van den Boogert, Jolanda; de Bruin, Ron W. F.; van Staveren, Hugo J.; Siersema, Peter D.; van Hillegersberg, Richard
1999-02-01
Photodynamic therapy (PDT) is an experimental treatment modality for (pre)malignant oesophageal lesions. 5- Aminolevulinic acid (ALA)-induced, protoporphyrin IX (PpIX)- mediated photo-sensitization could be very useful as ALA- induced porphrin accumulation selectively occurs in the oesophageal epithelium. The present study aimed to optimize the time between illumination and the administration of ALA. 200 mg/kg ALA was given orally to 24 rats (allocated to 6 groups of 4 animals each). Four animals served as controls and received phosphate buffered saline orally. The animals were illuminated at various time-points (either 1, 2, 3, 4, 6, or 12 hours) after ALA administration. Illumination was performed with a cylindrical diffuser placed in a balloon catheter. The device was originally made for percutaneous transluminal coronary angioplasty and consisted of a semi-flexible catheter and an inflatable cylindric optically clear balloon. The diffuser was placed centrally in the catheter. The same illumination parameters (633 nm, 25 J radiant energy/cm diffuser, power output 100 mW/cm diffuser) were used for each animal. During illumination, fluorescence measurements and light dosimetry were performed. The animals were sacrificed at 48 hours after PDT for histological assessment. Highest PpIX fluorescence was found at 2, 3, and 4 hours after ALA administration. Dosimetric measurements showed a 2 - 3 times higher in vivo fluence rate compared to the estimated fluence rate. Histology at 48 hours after PDT showed diffuse epithelial damage at the laser site only in rats illuminated at 2 hours after ALA administration. Illumination at 3, 4, and 6 hours after ALA administration resulted in diffuse epithelial damage in only one of four rats. In none of the rats illuminated at 1 and 12 hours after administration of ALA epithelial damage was found. These results show that illumination at 2 hours after oral ALA administration provides an efficient and safe scheme for ALA-PDT in the normal rat oesophagus. Illumination at other time points results in incomplete epithelial damage.
NASA Astrophysics Data System (ADS)
Lizotte, Todd E.; Ohar, Orest
2004-02-01
Illuminators used in machine vision applications typically produce non-uniform illumination onto the targeted surface being observed, causing a variety of problems with machine vision alignment or measurement. In most circumstances the light source is broad spectrum, leading to further problems with image quality when viewed through a CCD camera. Configured with a simple light bulb and a mirrored reflector and/or frosted glass plates, these general illuminators are appropriate for only macro applications. Over the last 5 years newer illuminators have hit the market including circular or rectangular arrays of high intensity light emitting diodes. These diode arrays are used to create monochromatic flood illumination of a surface that is to be inspected. The problem with these illumination techniques is that most of the light does not illuminate the desired areas, but broadly spreads across the surface, or when integrated with diffuser elements, tend to create similar shadowing effects to the broad spectrum light sources. In many cases a user will try to increase the performance of these illuminators by adding several of these assemblies together, increasing the intensity or by moving the illumination source closer or farther from the surface being inspected. In this case these non-uniform techniques can lead to machine vision errors, where the computer machine vision may read false information, such as interpreting non-uniform lighting or shadowing effects as defects. This paper will cover a technique involving the use of holographic / diffractive hybrid optical elements that are integrated into standard and customized light sources used in the machine vision industry. The bulk of the paper will describe the function and fabrication of the holographic/diffractive optics and how they can be tailored to improve illuminator design. Further information will be provided a specific design and examples of it in operation will be disclosed.
Effects of chromatic image statistics on illumination induced color differences.
Lucassen, Marcel P; Gevers, Theo; Gijsenij, Arjan; Dekker, Niels
2013-09-01
We measure the color fidelity of visual scenes that are rendered under different (simulated) illuminants and shown on a calibrated LCD display. Observers make triad illuminant comparisons involving the renderings from two chromatic test illuminants and one achromatic reference illuminant shown simultaneously. Four chromatic test illuminants are used: two along the daylight locus (yellow and blue), and two perpendicular to it (red and green). The observers select the rendering having the best color fidelity, thereby indirectly judging which of the two test illuminants induces the smallest color differences compared to the reference. Both multicolor test scenes and natural scenes are studied. The multicolor scenes are synthesized and represent ellipsoidal distributions in CIELAB chromaticity space having the same mean chromaticity but different chromatic orientations. We show that, for those distributions, color fidelity is best when the vector of the illuminant change (pointing from neutral to chromatic) is parallel to the major axis of the scene's chromatic distribution. For our selection of natural scenes, which generally have much broader chromatic distributions, we measure a higher color fidelity for the yellow and blue illuminants than for red and green. Scrambled versions of the natural images are also studied to exclude possible semantic effects. We quantitatively predict the average observer response (i.e., the illuminant probability) with four types of models, differing in the extent to which they incorporate information processing by the visual system. Results show different levels of performance for the models, and different levels for the multicolor scenes and the natural scenes. Overall, models based on the scene averaged color difference have the best performance. We discuss how color constancy algorithms may be improved by exploiting knowledge of the chromatic distribution of the visual scene.
Kim, Min-Jeong; Tang, Chee Hwa; Bang, Woo Suk; Yuk, Hyun-Gyun
2017-03-06
To investigate a potential of 405±5nm light emitting diode (LED) as a novel technology for food preservation, the antibacterial effect of 405±5nm LED on Escherichia coli O157:H7, Listeria monocytogenes, and Salmonella spp. on the surface of fresh-cut mango and its influence on fruit quality were evaluated at different storage temperatures. LED-illumination inactivated 1.0-1.6 logCFU/cm 2 of populations at 4 and 10°C for 36-48h (total dose, 2.6-3.5kJ/cm 2 ) regardless of bacterial species, while those on non-illuminated mange remained unchanged or slightly increased during storage. At 20°C for 24h (total dose, 1.7kJ/cm 2 ), non-illuminated E. coli O157:H7 and Salmonella gradually grew, whereas LED-illumination reduced 1.2 log of Salmonella and inhibited the growth of E. coli O157:H7. Unlike these, non-illuminated L. monocytogenes cells rapidly increased to 7.3 log, while illuminated cells reached 4.6 log, revealing that LED-illumination delayed their growth. There were no significant (P>0.05) differences in color, antioxidant capacity, ascorbic acid, β-carotene, and flavonoid between non-illuminated and illuminated cut mangoes, regardless of storage temperature. These results suggest that 405±5nm LEDs in combination with chilling temperatures could be applied to preserve fresh-cut fruits without deterioration of physicochemical quality of fruits at food establishments, minimizing the risk of foodborne disease. Copyright © 2017 Elsevier B.V. All rights reserved.
Oleari, Claudio; Melgosa, Manuel; Huertas, Rafael
2011-11-01
The most widely used color-difference formulas are based on color-difference data obtained under D65 illumination or similar and for a 10° visual field; i.e., these formulas hold true for the CIE 1964 observer adapted to D65 illuminant. This work considers the psychometric color-vision model based on the Optical Society of America-Uniform Color Scales (OSA-UCS) system previously published by the first author [J. Opt. Soc. Am. A 21, 677 (2004); Color Res. Appl. 30, 31 (2005)] with the additional hypothesis that complete illuminant adaptation with perfect color constancy exists in the visual evaluation of color differences. In this way a computational procedure is defined for color conversion between different illuminant adaptations, which is an alternative to the current chromatic adaptation transforms. This color conversion allows the passage between different observers, e.g., CIE 1964 and CIE 1931. An application of this color conversion is here made in the color-difference evaluation for any observer and in any illuminant adaptation: these transformations convert tristimulus values related to any observer and illuminant adaptation to those related to the observer and illuminant adaptation of the definition of the color-difference formulas, i.e., to the CIE 1964 observer adapted to the D65 illuminant, and then the known color-difference formulas can be applied. The adaptations to the illuminants A, C, F11, D50, Planckian and daylight at any color temperature and for CIE 1931 and CIE 1964 observers are considered as examples, and all the corresponding transformations are given for practical use.
Tolerancing a lens for LED uniform illumination
NASA Astrophysics Data System (ADS)
Ryu, Jieun; Sasian, Jose
2017-08-01
A method to evaluate tolerance sensitivities for lenses used to produce uniform illumination is presented. Closed form surfaces are used to define optical surfaces and relative illumination is calculated from light etendue considerations.
Dual LED/incandescent security fixture
Gauna, Kevin Wayne
2005-06-21
A dual LED and incandescent security lighting system uses a hybrid approach to LED illumination. It combines an ambient LED illuminator with a standard incandescent lamp on a motion control sensor. The LED illuminator will activate with the onset of darkness (daylight control) and typically remain on during the course of the night ("always on"). The LED illumination, typically amber, is sufficient to provide low to moderate level lighting coverage to the wall and ground area adjacent to and under the fixture. The incandescent lamp is integrated with a motion control circuit and sensor. When movement in the field of view is detected (after darkness), the incandescent lamp is switched on, providing an increased level of illumination to the area. Instead of an "always on" LED illuminator, the LEDs may also be switched off when the incandescent lamp is switched on.
Laser agile illumination for object tracking and classification - Feasibility study
NASA Technical Reports Server (NTRS)
Scholl, Marija S.; Vanzyl, Jakob J.; Meinel, Aden B.; Meinel, Marjorie P.; Scholl, James W.
1988-01-01
The 'agile illumination' concept for discrimination between ICBM warheads and decoys involves a two-aperture illumination with coherent light, diffraction of light by propagation, and a resulting interference pattern on the object surface. A scanning two-beam interference pattern illuminates one object at a time; depending on the shape, momentum, spinning, and tumbling characteristics of the interrogated object, different temporal signals will be obtained for different classes of objects.
Huang, Hsin-Tao; Tsai, Chuang-Chuang; Huang, Yi-Pai
2010-08-01
The UV-excited flat lighting (UFL) technique differs from conventional fluorescent lamp or LED illumination. It involves using a remote phosphor film to convert the wavelength of UV light to visible light, achieving high brightness and planar and uniform illumination. In particular, UFL can accomplish compact size, low power consumption, and symmetrical dual-sided illumination. Additionally, UFL utilizes a thermal radiation mechanism to release the large amount of heat that is generated upon illumination without thermal accumulation. These characteristics of the UFL technique can motivate a wide range of lighting applications in thin-film transistor LCD backlighting or general lighting.
Hertog, W; Llenas, A; Carreras, J
2015-11-30
This article demonstrates the benefits of complementing a daylight-lit environment with a spectrally tunable illumination system. The spectral components of daylight present in the room are measured by a low-cost miniature spectrophotometer and processed through a number of optimization algorithms, carefully trading color fidelity for energy efficiency. Spectrally-tunable luminaires provide only those wavelengths that ensure that either the final illumination spectrum inside the room is kept constant or carefully follows the dynamic spectral pattern of natural daylight. Analyzing the measured data proves that such a hybrid illumination system brings both unprecendented illumination quality and significant energy savings.
Off-axis illumination direct-to-digital holography
Thomas, Clarence E.; Price, Jeffery R.; Voelkl, Edgar; Hanson, Gregory R.
2004-06-08
Systems and methods are described for off-axis illumination direct-to-digital holography. A method of recording an off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis, includes: reflecting a reference beam from a reference mirror at a non-normal angle; reflecting an object beam from an object at an angle with respect to an optical axis defined by a focusing lens; focusing the reference beam and the object beam at a focal plane of a digital recorder to form the off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis; digitally recording the off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis; Fourier analyzing the recorded off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes by transforming axes of the recorded off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes in Fourier space to sit on top of a heterodyne carrier frequency defined as an angle between the reference beam and the object beam; applying a digital filter to cut off signals around an original origin; and then performing an inverse Fourier transform.
Digital micromirror device-based laser-illumination Fourier ptychographic microscopy
Kuang, Cuifang; Ma, Ye; Zhou, Renjie; Lee, Justin; Barbastathis, George; Dasari, Ramachandra R.; Yaqoob, Zahid; So, Peter T. C.
2015-01-01
We report a novel approach to Fourier ptychographic microscopy (FPM) by using a digital micromirror device (DMD) and a coherent laser source (532 nm) for generating spatially modulated sample illumination. Previously demonstrated FPM systems are all based on partially-coherent illumination, which offers limited throughput due to insufficient brightness. Our FPM employs a high power coherent laser source to enable shot-noise limited high-speed imaging. For the first time, a digital micromirror device (DMD), imaged onto the back focal plane of the illumination objective, is used to generate spatially modulated sample illumination field for ptychography. By coding the on/off states of the micromirrors, the illumination plane wave angle can be varied at speeds more than 4 kHz. A set of intensity images, resulting from different oblique illuminations, are used to numerically reconstruct one high-resolution image without obvious laser speckle. Experiments were conducted using a USAF resolution target and a fiber sample, demonstrating high-resolution imaging capability of our system. We envision that our approach, if combined with a coded-aperture compressive-sensing algorithm, will further improve the imaging speed in DMD-based FPM systems. PMID:26480361
Digital micromirror device-based laser-illumination Fourier ptychographic microscopy.
Kuang, Cuifang; Ma, Ye; Zhou, Renjie; Lee, Justin; Barbastathis, George; Dasari, Ramachandra R; Yaqoob, Zahid; So, Peter T C
2015-10-19
We report a novel approach to Fourier ptychographic microscopy (FPM) by using a digital micromirror device (DMD) and a coherent laser source (532 nm) for generating spatially modulated sample illumination. Previously demonstrated FPM systems are all based on partially-coherent illumination, which offers limited throughput due to insufficient brightness. Our FPM employs a high power coherent laser source to enable shot-noise limited high-speed imaging. For the first time, a digital micromirror device (DMD), imaged onto the back focal plane of the illumination objective, is used to generate spatially modulated sample illumination field for ptychography. By coding the on/off states of the micromirrors, the illumination plane wave angle can be varied at speeds more than 4 kHz. A set of intensity images, resulting from different oblique illuminations, are used to numerically reconstruct one high-resolution image without obvious laser speckle. Experiments were conducted using a USAF resolution target and a fiber sample, demonstrating high-resolution imaging capability of our system. We envision that our approach, if combined with a coded-aperture compressive-sensing algorithm, will further improve the imaging speed in DMD-based FPM systems.
Color constancy in 3D-2D face recognition
NASA Astrophysics Data System (ADS)
Meyer, Manuel; Riess, Christian; Angelopoulou, Elli; Evangelopoulos, Georgios; Kakadiaris, Ioannis A.
2013-05-01
Face is one of the most popular biometric modalities. However, up to now, color is rarely actively used in face recognition. Yet, it is well-known that when a person recognizes a face, color cues can become as important as shape, especially when combined with the ability of people to identify the color of objects independent of illuminant color variations. In this paper, we examine the feasibility and effect of explicitly embedding illuminant color information in face recognition systems. We empirically examine the theoretical maximum gain of including known illuminant color to a 3D-2D face recognition system. We also investigate the impact of using computational color constancy methods for estimating the illuminant color, which is then incorporated into the face recognition framework. Our experiments show that under close-to-ideal illumination estimates, one can improve face recognition rates by 16%. When the illuminant color is algorithmically estimated, the improvement is approximately 5%. These results suggest that color constancy has a positive impact on face recognition, but the accuracy of the illuminant color estimate has a considerable effect on its benefits.
Hybrid daylight/light-emitting diode illumination system for indoor lighting.
Ge, Aiming; Qiu, Peng; Cai, Jinlin; Wang, Wei; Wang, Junwei
2014-03-20
A hybrid illumination method using both daylight and light-emitting diodes (LEDs) for indoor lighting is presented in this study. The daylight can be introduced into the indoor space by a panel-integration system. The daylight part and LEDs are combined within a specific luminaire that can provide uniform illumination. The LEDs can be turned on and dimmed through closed-loop control when the daylight illuminance is inadequate. We simulated the illumination and calculated the indoor lighting efficiency of our hybrid daylight and LED lighting system, and compared this with that of LED and fluorescent lighting systems. Simulation results show that the efficiency of the hybrid daylight/LED illumination method is better than that of LED and traditional lighting systems, under the same lighting conditions and lighting time; the method has hybrid lighting average energy savings of T5 66.28%, and that of the LEDs is 41.62%.
NASA Astrophysics Data System (ADS)
Chang, Chia-Yuan; Chen, Shean-Jen
2017-02-01
Conventional temporal focusing-based multiphoton excitation microscopy (TFMPEM) can offer widefield optical sectioning with an axial excitation confinement (AEC) of a few microns. Herein, a developed TFMPEM with a digital micromirror device (DMD), acting as the blazed grating for light spatial dispersion and simultaneous patterned illumination, has been extended to implement spatially modulated illumination at structured frequency and orientation. By implementing the spatially modulated illumination, the beam coverage at the back-focal aperture of the objective lens can be increased. As a result, the AEC can be condensed from 3.0 μm to 1.5 μm in full width at half maximum for a 2-fold enhancement. Furthermore, by using HiLo microscopy with two structured illuminations at the same spatial frequency but different orientation, biotissue images according to the structured illumination with condensed AEC is obviously superior in contrast and scattering suppression.
Effects of color combination and ambient illumination on visual perception time with TFT-LCD.
Lin, Chin-Chiuan; Huang, Kuo-Chen
2009-10-01
An empirical study was carried out to examine the effects of color combination and ambient illumination on visual perception time using TFT-LCD. The effect of color combination was broken down into two subfactors, luminance contrast ratio and chromaticity contrast. Analysis indicated that the luminance contrast ratio and ambient illumination had significant, though small effects on visual perception. Visual perception time was better at high luminance contrast ratio than at low luminance contrast ratio. Visual perception time under normal ambient illumination was better than at other ambient illumination levels, although the stimulus color had a confounding effect on visual perception time. In general, visual perception time was better for the primary colors than the middle-point colors. Based on the results, normal ambient illumination level and high luminance contrast ratio seemed to be the optimal choice for design of workplace with video display terminals TFT-LCD.
NASA Astrophysics Data System (ADS)
Gao, Jin-gui; Zhao, Hong-gang; Luo, Lai-peng
2017-04-01
In this paper, MJ3310A band saw machine as the research object, through the Beijing VIBSYS vibration signal acquisition and analysis software illumination value analysis, analysis of different circumstances to find good and crack band saw blade illumination value of the law. The results show that the illuminance of the cracked band saw blade is significantly higher than that of the complete band saw blade illumination value. Under the optimum working conditions, if the band saw blade illumination value exceeds 286 Lux, it can be determined that the band saw blade has at least one crack length greater than 1.68 mm Of the defects, the need for timely replacement band saw blade. So as to rational use of band saw blade, band saw blade on-line fault diagnosis provides a technical basis.
Influence of illuminants on the color distribution of shade guides.
Park, Ji-Hoon; Lee, Yong-Keun; Lim, Bum-Soon
2006-12-01
Although a shade tab in a shade guide is matched to a natural tooth in the order of value, hue, and chroma, there are limited data on the color distribution of currently available shade guides sorted by these 3 parameters. Furthermore, spectrophotometric color measurements of shade tabs differ depending on the standard illuminant employed. The purpose of this study was to determine the color distributions of 2 shade guides in value (CIE L( *)), chroma (C( *)(ab)) and hue angle (h(o)) scale relative to the standard illuminants D(65), A, and F2. Color of shade tabs (n=36) from 2 shade guides (Vita Lumin and Chromascop) were measured, and the distributions for CIE L( *), C( *)(ab) and h(o) values were compared. Color differences of shade tabs depending on the illuminant were calculated. The distributions of the ratios of CIE L( *) and C( *)(ab) values of each shade tab compared with the lowest value tab or the lowest chroma tab were determined. The data for the value, chroma, and hue angle within each shade guide were analyzed with a 2-way ANOVA with the factors of shade designation and type of illuminant (alpha=.05). Color difference caused by change of illuminant was analyzed with a 2-way ANOVA with the factors of shade designation and pair of illuminants compared (alpha=.05). The Scheffe multiple comparison test was performed as a post hoc test. CIE L( *), C( *)(ab) and h(o) values were influenced by shade designation and type of illuminant in both shade guides. Color difference caused by change of the illuminant was influenced by the shade designation and pair of illuminants compared. The order of mean color differences of 16 Vita Lumin shade tabs by pairs of illuminants compared was as follows: DeltaE( *)(ab) (D(65)/F2) = 1.63
Slow updating of the achromatic point after a change in illumination
Lee, R. J.; Dawson, K. A.; Smithson, H. E.
2015-01-01
For a colour constant observer, the colour appearance of a surface is independent of the spectral composition of the light illuminating it. We ask how rapidly colour appearance judgements are updated following a change in illumination. We obtained repeated binary colour classifications for a set of stimuli defined by their reflectance functions and rendered under either sunlight or skylight. We used these classifications to derive boundaries in colour space that identify the observer’s achromatic point. In steady-state conditions of illumination, the achromatic point lay close to the illuminant chromaticity. In our experiment the illuminant changed abruptly every 21 seconds (at the onset of every 10th trial), allowing us to track changes in the achromatic point that were caused by the cycle of illuminant changes. In one condition, the test reflectance was embedded in a spatial pattern of reflectance samples under consistent illumination. The achromatic point migrated across colour space between the chromaticities of the steady-state achromatic points. This update took several trials rather than being immediate. To identify the factors that governed perceptual updating of appearance judgements we used two further conditions, one in which the test reflectance was presented in isolation and one in which the surrounding reflectances were rendered under an inconsistent and unchanging illumination. Achromatic settings were not well predicted by the information available from scenes at a single time-point. Instead the achromatic points showed a strong dependence on the history of chromatic samples. The strength of this dependence differed between observers and was modulated by the spatial context. PMID:22275468
Pakkala, T; Kuusela, L; Ekholm, M; Wenzel, A; Haiter-Neto, F; Kortesniemi, M
2012-01-01
In clinical practice, digital radiographs taken for caries diagnostics are viewed on varying types of displays and usually in relatively high ambient lighting (room illuminance) conditions. Our purpose was to assess the effect of room illuminance and varying display types on caries diagnostic accuracy in digital dental radiographs. Previous studies have shown that the diagnostic accuracy of caries detection is significantly better in reduced lighting conditions. Our hypothesis was that higher display luminance could compensate for this in higher ambient lighting conditions. Extracted human teeth with approximal surfaces clinically ranging from sound to demineralized were radiographed and evaluated by 3 observers who detected carious lesions on 3 different types of displays in 3 different room illuminance settings ranging from low illumination, i.e. what is recommended for diagnostic viewing, to higher illumination levels corresponding to those found in an average dental office. Sectioning and microscopy of the teeth validated the presence or absence of a carious lesion. Sensitivity, specificity and accuracy were calculated for each modality and observer. Differences were estimated by analyzing the binary data assuming the added effects of observer and modality in a generalized linear model. The observers obtained higher sensitivities in lower illuminance settings than in higher illuminance settings. However, this was related to a reduction in specificity, which meant that there was no significant difference in overall accuracy. Contrary to our hypothesis, there were no significant differences between the accuracy of different display types. Therefore, different displays and room illuminance levels did not affect the overall accuracy of radiographic caries detection. Copyright © 2012 S. Karger AG, Basel.
Illuminated push-button switch
NASA Technical Reports Server (NTRS)
Iwagiri, T.
1983-01-01
An illuminated push-button switch is described. It is characterized by the fact that is consists of a switch group, an operator button opening and closing the switch group, and a light-emitting element which illuminates the face of the operator button.
Gokce, Hasan Suat; Piskin, Bulent; Ceyhan, Dogan; Gokce, Sila Mermut; Arisan, Volkan
2010-03-01
The lighting conditions of the environment and visual deficiencies such as red-green color vision deficiency affect the clinical shade matching performance of dental professionals. The purpose of this study was to evaluate the shade matching performance of normal and color vision-deficient dental professionals with standard daylight and tungsten illuminants. Two sets of porcelain disc replicas of 16 shade guide tabs (VITA Lumin) were manufactured to exact L*a*b* values by using a colorimeter. Then these twin porcelain discs (13 mm x 2.4 mm) were mixed up and placed into a color-matching cabinet that standardized the lighting conditions for the observation tests. Normal and red-green color vision-deficient dental professionals were asked to match the 32 porcelain discs using standard artificial daylight D65 (high color temperature) and tungsten filament lamp light (T) (low color temperature) illuminants. The results were analyzed by repeated-measures ANOVA and paired and independent samples t tests for the differences between dental professionals and differences between the illuminants (alpha=.05). Regarding the sum of the correct shade match scores of all observations with both illuminants, the difference between normal vision and red-green color vision-deficient dental professional groups was not statistically significant (F=4.132; P=.054). However, the correct shade match scores of each group were significantly different for each illuminant (P<.005). The correct shade matching scores of normal color vision dental professionals were significantly higher with D65 illuminant (t=7.004; P<.001). Color matching scores of red-green color vision-deficient dental professionals (approximately 5.7 more pairs than with D65) were significantly higher with T illuminant (t=5.977; P<.001). CONCLUSIONS.: Within the limitations of this study, the shade matching performance of dental professionals was affected by color vision deficiency and the color temperature of the illuminant. The color vision-deficient group was notably unsuccessful with the D65 illuminant in shade matching. In contrast, there was a significant increase in the shade matching performance of the color vision-deficient group with T illuminant. The lower color temperature illuminant dramatically decreased the normal color vision groups' correct shade matching score. (c) 2010 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
IR Image upconversion using band-limited ASE illumination fiber sources.
Maestre, H; Torregrosa, A J; Capmany, J
2016-04-18
We study the field-of-view (FOV) of an upconversion imaging system that employs an Amplified Spontaneous Emission (ASE) fiber source to illuminate a transmission target. As an intermediate case between narrowband laser and thermal illumination, an ASE fiber source allows for higher spectral intensity than thermal illumination and still keeps a broad wavelength spectrum to take advantage of an increased non-collinear phase-matching angle acceptance that enlarges the FOV of the upconversion system when compared to using narrowband laser illumination. A model is presented to predict the angular acceptance of the upconverter in terms of focusing and ASE spectral width and allocation. The model is experimentally checked in case of 1550-630 nm upconversion.
Even illumination in total internal reflection fluorescence microscopy using laser light.
Fiolka, R; Belyaev, Y; Ewers, H; Stemmer, A
2008-01-01
In modern fluorescence microscopy, lasers are a widely used source of light, both for imaging in total internal reflection and epi-illumination modes. In wide-field imaging, scattering of highly coherent laser light due to imperfections in the light path typically leads to nonuniform illumination of the specimen, compromising image analysis. We report the design and construction of an objective-launch total internal reflection fluorescence microscopy system with excellent evenness of specimen illumination achieved by azimuthal rotation of the incoming illuminating laser beam. The system allows quick and precise changes of the incidence angle of the laser beam and thus can also be used in an epifluorescence mode. 2007 Wiley-Liss, Inc
Improvement of illumination uniformity for LED flat panel light by using micro-secondary lens array.
Lee, Hsiao-Wen; Lin, Bor-Shyh
2012-11-05
LED flat panel light is an innovative lighting product in recent years. However, current flat panel light products still contain some drawbacks, such as narrow lighting areas and hot spots. In this study, a micro-secondary lens array technique was proposed and applied for the design of the light guide surface to improve the illumination uniformity. By using the micro-secondary lens array, the candela distribution of the LED flat panel light can be adjusted to similar to batwing distribution to improve the illumination uniformity. The experimental results show that the enhancement of the floor illumination uniformity is about 61%, and that of the wall illumination uniformity is about 20.5%.
Scattering and absorption control in biocompatible fibers towards equalized photobiomodulation.
George, J; Haghshenas, H; d'Hemecourt, D; Zhu, W; Zhang, L; Sorger, V
2017-03-01
Transparent tissue scaffolds enable illumination of growing tissue to accelerate cell proliferation and improve other cell functions through photobiomodulation. The biphasic dose response of cells exposed to photobiomodulating light dictates that the illumination be evenly distributed across the scaffold such that the cells are neither under nor over exposed to light. However, equalized illumination has not been sufficiently addressed. Here we analyze and experimentally demonstrate spatially equalizing illumination by three methods, namely: engineered surface scattering, reflection by a gold mirror, and traveling-waves in a ring mesh. Our results show that nearly equalized illumination is achievable by controlling the light scattering-to-loss ratio. This demonstration furthers opportunities for dose-optimized photobiomodulation in tissue regeneration.
Design of illumination system in ring field capsule endoscope
NASA Astrophysics Data System (ADS)
Jeng, Wei-De; Mang, Ou-Yang; Chen, Yu-Ta; Wu, Ying-Yi
2011-03-01
This paper is researching about the illumination system in ring field capsule endoscope. It is difficult to obtain the uniform illumination on the observed object because the light intensity of LED will be changed along its angular displacement and same as luminous intensity distribution curve. So we use the optical design software which is Advanced Systems Analysis Program (ASAP) to build a photometric model for the optimal design of LED illumination system in ring field capsule endoscope. In this paper, the optimal design of illumination uniformity in the ring field capsule endoscope is from origin 0.128 up to optimum 0.603 and it would advance the image quality of ring field capsule endoscope greatly.
Chen, Yibing; Ogata, Taiki; Ueyama, Tsuyoshi; Takada, Toshiyuki; Ota, Jun
2018-01-01
Machine vision is playing an increasingly important role in industrial applications, and the automated design of image recognition systems has been a subject of intense research. This study has proposed a system for automatically designing the field-of-view (FOV) of a camera, the illumination strength and the parameters in a recognition algorithm. We formulated the design problem as an optimisation problem and used an experiment based on a hierarchical algorithm to solve it. The evaluation experiments using translucent plastics objects showed that the use of the proposed system resulted in an effective solution with a wide FOV, recognition of all objects and 0.32 mm and 0.4° maximal positional and angular errors when all the RGB (red, green and blue) for illumination and R channel image for recognition were used. Though all the RGB illumination and grey scale images also provided recognition of all the objects, only a narrow FOV was selected. Moreover, full recognition was not achieved by using only G illumination and a grey-scale image. The results showed that the proposed method can automatically design the FOV, illumination and parameters in the recognition algorithm and that tuning all the RGB illumination is desirable even when single-channel or grey-scale images are used for recognition. PMID:29786665
Chen, Yibing; Ogata, Taiki; Ueyama, Tsuyoshi; Takada, Toshiyuki; Ota, Jun
2018-05-22
Machine vision is playing an increasingly important role in industrial applications, and the automated design of image recognition systems has been a subject of intense research. This study has proposed a system for automatically designing the field-of-view (FOV) of a camera, the illumination strength and the parameters in a recognition algorithm. We formulated the design problem as an optimisation problem and used an experiment based on a hierarchical algorithm to solve it. The evaluation experiments using translucent plastics objects showed that the use of the proposed system resulted in an effective solution with a wide FOV, recognition of all objects and 0.32 mm and 0.4° maximal positional and angular errors when all the RGB (red, green and blue) for illumination and R channel image for recognition were used. Though all the RGB illumination and grey scale images also provided recognition of all the objects, only a narrow FOV was selected. Moreover, full recognition was not achieved by using only G illumination and a grey-scale image. The results showed that the proposed method can automatically design the FOV, illumination and parameters in the recognition algorithm and that tuning all the RGB illumination is desirable even when single-channel or grey-scale images are used for recognition.
Color constancy influenced by unnatural spatial structure.
Mizokami, Yoko; Yaguchi, Hirohisa
2014-04-01
The recognition of spatial structures is important for color constancy because we cannot identify an object's color under different illuminations without knowing which space it is in and how that space is illuminated. To show the importance of the natural structure of environments on color constancy, we investigated the way in which color appearance was affected by unnatural viewing conditions in which a spatial structure was distorted. Observers judged the color of a test patch placed in the center of a small room illuminated by white or reddish lights, as well as two rooms illuminated by white and reddish light, respectively. In the natural viewing condition, an observer saw the room(s) through a viewing window, whereas in an unnatural viewing condition, the scene structure was scrambled by a kaleidoscope-type viewing box. Results of single room condition with one illuminant color showed little difference in color constancy between the two viewing conditions. However, it decreased in the two-rooms condition with a more complex arrangement of space and illumination. The patch's appearance under the unnatural viewing condition was more influenced by simultaneous contrast than its appearance under the natural viewing condition. It also appears that color appearance under white illumination is more stable compared to that under reddish illumination. These findings suggest that natural spatial structure plays an important role for color constancy in a complex environment.
Biological Effects Of Artificial Illumination
NASA Astrophysics Data System (ADS)
Corth, Richard
1980-10-01
We are increasingly being warned of the possible effects of so called "polluted" light, that is light that differs in spectral content from that of sunlight. We should be concerned, we are told, because all animals and plants have evolved under this natural daylight and therefore any difference between that illuminant and the artificial illuminants that are on the market today, is suspect. The usual presentation of the differences between the sunlight and the artificial illuminants are as shown in Figure 1. Here we are shown the spectral power distribution of sunlight and Cool White fluorescent light. The spectral power distributions of each have been normalized to some convenient wavelength so that each can be seen and easily compared on the same figure. But this presentation is misleading for one does not experience artificial illuminants at the same intensity as one experiences sunlight. Sunlight intensities are ordinarily found to be in the 8000 to 10,000 footcandle range whereas artificial illuminants are rarely experienced at intensity levels greater than 100 footcandles. Therefore a representative difference between the two types of illumination conditions is more accurately represented as in Figure 2. Thus if evolutionary adaptations require that humans and other animals be exposed to sunlight to ensure wellbeing, it is clear that one must be exposed to sunlight intensities. It is not feasible to expect that artificially illuminated environments will be lit to the same intensity as sunlight
Improved illumination system of laparoscopes using an aspherical lens array.
Wu, Rengmao; Qin, Yi; Hua, Hong
2016-06-01
The current fiber-based illumination systems of laparoscopes are unable to uniformly illuminate a large enough area in abdomen due to the limited numerical aperture (NA) of the fiber bundle. Most energy is concentrated in a small region at the center of the illumination area. This limitation becomes problematic in laparoscopes which require capturing a wide field of view. In this paper, we propose an aspherical lens array which is used to direct the outgoing rays from the fiber bundle of laparoscope to produce a more uniformly illuminated, substantially larger field coverage than standalone fiber source. An intensity feedback method is developed to design the aspherical lens unit for extended non-Lambertian sources, which is the key to the design of this lens array. By this method, the lens unit is obtained after only one iteration, and the lens array is constructed by Boolean operation. Then, the ray-tracing technique is used to verify the design. Further, the lens array is fabricated and experimental tests are performed. The results clearly show that the well-illuminated area is increased to about 0.107m(2) from 0.02m(2) (about 5x larger than a standard fiber illumination source). More details of the internal organs can be clearly observed under this improved illumination condition, which also reflects the significant improvement in the optical performance of the laparoscope.
Yi, Jizheng; Mao, Xia; Chen, Lijiang; Xue, Yuli; Rovetta, Alberto; Caleanu, Catalin-Daniel
2015-01-01
Illumination normalization of face image for face recognition and facial expression recognition is one of the most frequent and difficult problems in image processing. In order to obtain a face image with normal illumination, our method firstly divides the input face image into sixteen local regions and calculates the edge level percentage in each of them. Secondly, three local regions, which meet the requirements of lower complexity and larger average gray value, are selected to calculate the final illuminant direction according to the error function between the measured intensity and the calculated intensity, and the constraint function for an infinite light source model. After knowing the final illuminant direction of the input face image, the Retinex algorithm is improved from two aspects: (1) we optimize the surround function; (2) we intercept the values in both ends of histogram of face image, determine the range of gray levels, and stretch the range of gray levels into the dynamic range of display device. Finally, we achieve illumination normalization and get the final face image. Unlike previous illumination normalization approaches, the method proposed in this paper does not require any training step or any knowledge of 3D face and reflective surface model. The experimental results using extended Yale face database B and CMU-PIE show that our method achieves better normalization effect comparing with the existing techniques.
Evaluation of the cost-effectiveness of illumination as a safety treatment at rural intersections.
DOT National Transportation Integrated Search
2016-09-01
This research study seeks to improve current understanding of the relationship between rural intersection safety and different illumination levels. It uses three parallel studies: a survey of rural intersection illumination practices among US state d...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Surface Installations § 77.207 Illumination. Illumination sufficient to provide safe working conditions shall be...
Intermittent illumination increases biophotolytic hydrogen yield by Anabaena cylindrica
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeffries, T.W.; Leach, K.L.
Intermittent illumination increased H/sub 2/ and C/sub 2/H/sub 4/ yields per unit of light from growing cells and from nitrogen-starved cells by 1.7- and 1.35-fold, respectively, as compared with continuous illumination.
NASA Astrophysics Data System (ADS)
Tegegne, Z. G.; Viana, C.; Polleux, J. L.; Grzeskowiak, M.; Richalot, E.
2016-03-01
This paper demonstrates the experimental study of edge and top illuminated SiGe phototransistors (HPT) implemented using the existing industrial SiGe2RF Telefunken GmbH BiCMOS technology for opto-microwave (OM) applications using 850nm Multi-Mode Fibers (MMF). Its technology and structure are described. Two different optical window size HPTs with top illumination (5x5μm2, 10x10μm2) and an edge illuminated HPTs having 5μm x5μm size are presented and compared. A two-step post fabrication process was used to create an optical access on the edge of the HPT for lateral illumination with a lensed MMF through simple polishing and dicing techniques. We perform Opto-microwave Scanning Near-field Optical Microscopy (OM-SNOM) analysis on edge and top illuminated HPTs in order to observe the fastest and the highest sensitive regions of the HPTs. This analysis also allows understanding the parasitic effect from the substrate, and thus draws a conclusion on the design aspect of SiGe/Si HPT. A low frequency OM responsivity of 0.45A/W and a cutoff frequency, f-3dB, of 890MHz were measured for edge illuminated HPT. Compared to the top illuminated HPT of the same size, the edge illuminated HPT improves the f-3dB by a factor of more than two and also improves the low frequency responsivity by a factor of more than four. These results demonstrate that a simple etched HPT is still enough to achieve performance improvements compared to the top illuminated HPT without requiring a complex coupling structure. Indeed, it also proves the potential of edge coupled SiGe HPT in the ultra-low-cost silicon based optoelectronics circuits with a new approach of the optical packaging and system integration to 850nm MMF.
The Influence of Very Low Illumination on the Postural Sway of Young and Elderly Adults
Rugelj, Darja; Gomišček, Gregor; Sevšek, France
2014-01-01
The purpose of the present study was to evaluate the influence of very low ambient illumination and complete darkness on the postural sway of young and elderly adults. Eighteen healthy young participants aged 23.8±1.5 years and 26 community-dwelling elderly aged 69.8±5.6 years were studied. Each participant performed four tests while standing on a force platform in the following conditions: in normal light (215 lx) with open eyes and with closed eyes, in very low illumination (0.25 lx) with open eyes, and in complete darkness with open eyes. The sequences of the tests in the altered visual conditions were determined by random blocs. Postural sway was assessed by means of the force platform measurements. The centre of pressure variables: the medio-lateral and antero-posterior path lengths, mean velocities, sway areas, and fractal dimensions were analysed. Very low illumination resulted in a statistically significant increase in postural sway in both the young and elderly groups compared to normal light, although the increase was significantly smaller than those observed in the eyes closed and complete darkness condition, and no significant effects of illumination on fractal dimensions were detected. The gains of the sways in the very low or no illumination conditions relative to the normal light condition were significantly larger in the group of young participants than in the group of elderly participants (up to 50% and 25%, respectively). However, the response patterns to changes in illumination were similar in the young and elderly participants, with the exception of the short-range fractal dimension of the medio-lateral sway. In conclusion, very low illumination resulted in increased postural sway compared to normal illumination; however, in the closed eye and complete darkness conditions, postural sway was significantly higher than in the very low illumination condition regardless of the age of the participants. PMID:25084015
Portable system to luminaries characterization
NASA Astrophysics Data System (ADS)
Tecpoyotl-Torres, M.; Vera-Dimas, J. G.; Koshevaya, S.; Escobedo-Alatorre, J.; Cisneros-Villalobos, L.; Sanchez-Mondragon, J.
2014-09-01
For illumination sources designers is important to know the illumination distribution of their products. They can use several viewers of IES files (standard file format determined by Illuminating Engineering Society). This files are necessary not only know the distribution of illumination, but also to plain the construction of buildings by means of specialized softwares, such as Autodesk Revit. In this paper, a complete portable system for luminaries' characterization is given. The components of the systems are: Irradiance profile meter, which can generate photometry of luminaries of small sizes which covers indoor illumination requirements and luminaries for general areas. One of the meteŕs attributes is given by the color sensor implemented, which allows knowing the color temperature of luminary under analysis. The Graphic Unit Interface (GUI) has several characteristics: It can control the meter, acquires the data obtained by the sensor and graphs them in 2D under Cartesian and polar formats or 3D, in Cartesian format. The graph can be exported to png, jpg, or bmp formats, if necessary. These remarkable characteristics differentiate this GUI. This proposal can be considered as a viable option for enterprises of illumination design and manufacturing, due to the relatively low investment level and considering the complete illumination characterization provided.
NASA Astrophysics Data System (ADS)
Liang, Wenxuan; Murari, Kartikeya; Zhang, Yuying; Chen, Yongping; Li, Ming-Jun; Li, Xingde
2012-02-01
We compare the illumination uniformity and the associated effects of the spiral and Lissajous scanning patterns that are commonly used in an endomicroscope. Theoretical analyses and numerical simulations were first performed to quantitatively investigate the area illumination density in the spiral scanning pattern. The results revealed the potential problem of manifest photodamage due to the very high illumination density in the center of the spiral scan. Similar analyses of the Lissajous scanning pattern, which can be conveniently implemented on the same endomicroscope with no hardware modifications, showed a more uniform illumination density with about an 80-fold reduction in the peak illumination density. To underscore the benefit offered by the improved illumination uniformity, we conducted in vitro two-photon fluorescence imaging of cultured cells stained with a LIVE/DEAD viability assay using our home-built, fiber-optic, two-channel endomicroscopy system. Both the spiral and the Lissajous scans were implemented. Our experimental results showed that cells near the spiral scan center experienced obvious photodamage, whereas cells remained alive over the entire region under the Lissajous beam scanning, confirming the predicted advantage offered by the Lissajous scan over this spiral scan in an endomicroscopy setting.
NASA Astrophysics Data System (ADS)
Zhuang, Zhenfeng; Thibault, Simon
2017-11-01
One of the key issues in conventional wide-angle lenses is the well-known cosine-fourth power law problem causing the illumination falloff at its image space. This paper explores methods of improving illumination in the image space in panomorph lenses. By tracing skew rays within the defined field of view and pupil diameter, we obtained the actual position of the three-dimensional pupil model of the entrance pupil (EP) and exit pupil (XP). Based on the law of irradiance transport conservation, the relation between the area of the EP projection and illumination in the image space is derived to investigate the factors affecting the illumination on the peripheral field. A panomorph lens has been optimized as an example by providing a self-defined operation in the optimization process. The characteristic of the EP and XP in panomorph lenses is qualitatively analyzed. Compared with the conventional design method, the proposed design strategy can enhance the illumination with and without polarized light based on qualitatively evaluating the area of projected EP. It is demonstrated that this method enables the enhancement of the illumination without additional film coating.
Shimakawa, Ginga; Miyake, Chikahiro
2018-03-08
Oxygenic phototrophs are vulnerable to damage by reactive oxygen species (ROS) that are produced in photosystem I (PSI) by excess photon energy over the demand of photosynthetic CO 2 assimilation. In plant leaves, repetitive short-pulse (rSP) illumination produces ROS to inactivate PSI. The production of ROS is alleviated by oxidation of the reaction center chlorophyll in PSI, P700, during the illumination with the short-pulse light, which is supported by flavodiiron protein (FLV). In this study, we found that in the cyanobacterium Synechocystis sp. PCC 6803 P700 was oxidized and PSI was not inactivated during rSP illumination even in the absence of FLV. Conversely, the mutant deficient in respiratory terminal oxidases was impaired in P700 oxidation during the illumination with the short-pulse light to suffer from photo-oxidative damage in PSI. Interestingly, the other cyanobacterium Synechococcus sp. PCC 7002 could not oxidize P700 without FLV during rSP illumination. These data indicate that respiratory terminal oxidases are critical to protect PSI from ROS damage during rSP illumination in Synechocystis sp. PCC 6803 but not Synechococcus sp. PCC 7002.
Lunar South Pole Illumination: Review, Reassessment, and Power System Implications
NASA Technical Reports Server (NTRS)
Fincannon, James
2007-01-01
This paper reviews past analyses and research related to lunar south pole illumination and presents results of independent illumination analyses using an analytical tool and a radar digital elevation model. The analysis tool enables assessment at most locations near the lunar poles for any time and any year. Average illumination fraction, energy storage duration, solar/horizon terrain elevation profiles and illumination fraction profiles are presented for various highly illuminated sites which have been identified for manned or unmanned operations. The format of the data can be used by power system designers to develop mass optimized solar and energy storage systems. Data are presented for the worse case lunar day (a critical power planning bottleneck) as well as three lunar days during lunar south pole winter. The main site under consideration by present lunar mission planners (on the Crater Shackleton rim) is shown to have, for the worse case lunar day, a 0.71 average illumination fraction and 73 to 117 hours required for energy storage (depending on power system type). Linking other sites and including towers at either site are shown to not completely eliminate the need for energy storage.
Liu, Chao; Gu, Jinwei
2014-01-01
Classifying raw, unpainted materials--metal, plastic, ceramic, fabric, and so on--is an important yet challenging task for computer vision. Previous works measure subsets of surface spectral reflectance as features for classification. However, acquiring the full spectral reflectance is time consuming and error-prone. In this paper, we propose to use coded illumination to directly measure discriminative features for material classification. Optimal illumination patterns--which we call "discriminative illumination"--are learned from training samples, after projecting to which the spectral reflectance of different materials are maximally separated. This projection is automatically realized by the integration of incident light for surface reflection. While a single discriminative illumination is capable of linear, two-class classification, we show that multiple discriminative illuminations can be used for nonlinear and multiclass classification. We also show theoretically that the proposed method has higher signal-to-noise ratio than previous methods due to light multiplexing. Finally, we construct an LED-based multispectral dome and use the discriminative illumination method for classifying a variety of raw materials, including metal (aluminum, alloy, steel, stainless steel, brass, and copper), plastic, ceramic, fabric, and wood. Experimental results demonstrate its effectiveness.
Validation of an inexpensive test illuminant for aeromedical color vision screening.
DOT National Transportation Integrated Search
1993-09-01
An inexpensive illuminant for color vision screening suggested by the NRC-NAS Committee on Vision was evaluated as a substitute for the Macbeth Easel Lamp. The Macbeth Easel Lamp is the recommended illuminant for pseudoisochromatic plate tests used i...
IODC 2014 Illumination design problem: the Cinderella Lamp
NASA Astrophysics Data System (ADS)
Cassarly, William J.
2014-12-01
For the 3rd time, the International Optical Design Conference (IODC) included an Illumination Design contest. This year, the contest involved designing the illuminator to project the 1950 Walt Disney "Cinderella" movie using a box of optical knick-knacks. The goal of the problem was to provide the highest screen lumens with greater than 30% uniformity. There were 12 entries from 3 different countries. Three different commercial optical/illumination design packages were used. The winning solution, provided by Alois Herkommer, provided 371 screen lumens.
2010-11-01
Connecting the Medtronic MAST Quadrant Illumination System, Radiance Illumination System, or Radiance X Illumination System--all of which are specialized fiberoptic light cables used with the company's minimally invasive spinal products--to a high-power surgical light source significantly increases the risk of patient burns. Hospitals should ensure that the products are used only with 100 W light sources and 5 mm light cables, as prescribed in the product labeling.
Wide-field airborne laser diode array illuminator: demonstration results
NASA Astrophysics Data System (ADS)
Suiter, H. R.; Holloway, J. H., Jr.; Tinsley, K. R.; Pham, C. N.; Kloess, E. C., III; Witherspoon, N. H.; Stetson, S.; Crosby, F.; Nevis, A.; McCarley, K. A.; Seales, T. C.
2005-06-01
The Airborne Littoral Reconnaissance Technology (ALRT) program has successfully demonstrated the Wide-Field Airborne Laser Diode Array Illuminator (ALDAI-W). This illuminator is designed to illuminate a large area from the air with limited power, weight, and volume. A detection system, of which the ALDAI-W is a central portion, is capable of detecting surface-laid minefields in absolute darkness, extending the allowed mission times to night operations. This will be an overview report, giving processing results and suggested paths for additional development.
[Study on single-walled carbon nanotube thin film photoelectric device].
Xie, Wen-bin; Zhu, Yong; Gong, Tian-cheng; Chen, Yu-lin; Zhang, Jie
2015-01-01
The single-walled carbon nanotube film photoelectric device was invented, and it can generate net photocurrent under bias voltage when it is illuminated by the laser. The influences of bias voltage, laser power and illuminating position on the net photocurrent were investigated. The experimental results showed that when the center of the film was illuminated, the photocurrent increased with the applied bias, but tended to saturate as the laser power increased. As the voltage and the laser power reached 0. 2 V and 22. 7 mW respectively, the photocurrent reached 0. 24 µA. When the voltage was removed, the photocurrent varied with the laser illuminating position on the film and its value was distributed symmetrically about the center of the device. The photocurrent reached maximum and almost zero respectively when the laser illuminated on two ends and the center of the film. Analysis proposes that the net photocurrent can be generated due to internal photoelectric effect when the device is under voltage and the laser illuminates on the center of the film. It can be also generated due to photo-thermoelectric effect when the device is under no voltage and the laser illuminates on the film, and the relation between the net photocurrent and the illuminating position was derived according to the nature of thermoelectric power of single-walled carbon nanotubes with the established temperature model, which coincides with experimental result. Two effects are the reasons for the generation and variety of the net photocurrent and they superimpose to form the result of the net photocurrent when the device is under general conditions of voltage and laser illuminating position. The device has potential applications in the areas of photovoltaic device and optical sensor for its characteristic.
Back-illuminated imager and method for making electrical and optical connections to same
NASA Technical Reports Server (NTRS)
Pain, Bedabrata (Inventor)
2010-01-01
Methods for bringing or exposing metal pads or traces to the backside of a backside-illuminated imager allow the pads or traces to reside on the illumination side for electrical connection. These methods provide a solution to a key packaging problem for backside thinned imagers. The methods also provide alignment marks for integrating color filters and microlenses to the imager pixels residing on the frontside of the wafer, enabling high performance multispectral and high sensitivity imagers, including those with extremely small pixel pitch. In addition, the methods incorporate a passivation layer for protection of devices against external contamination, and allow interface trap density reduction via thermal annealing. Backside-illuminated imagers with illumination side electrical connections are also disclosed.
Role of color memory in successive color constancy.
Ling, Yazhu; Hurlbert, Anya
2008-06-01
We investigate color constancy for real 2D paper samples using a successive matching paradigm in which the observer memorizes a reference surface color under neutral illumination and after a temporal interval selects a matching test surface under the same or different illumination. We find significant effects of the illumination, reference surface, and their interaction on the matching error. We characterize the matching error in the absence of illumination change as the "pure color memory shift" and introduce a new index for successive color constancy that compares this shift against the matching error under changing illumination. The index also incorporates the vector direction of the matching errors in chromaticity space, unlike the traditional constancy index. With this index, we find that color constancy is nearly perfect.
Illumination-redistribution lenses for non-circular spots
NASA Astrophysics Data System (ADS)
Parkyn, William A.; Pelka, David G.
2005-08-01
The design of illumination lenses is far easier under the regime of the small-source approximation, whereby central rays are taken as representative of the entire source. This implies that the lens is much larger than the source's active emitter, and its entire interior surface is nowhere close to the source. Also, a given source luminance requires a minimum lens area to achieve the candlepower necessary for target illumination. We introduce two-surface aspheric lenses for specific illuminations tasks involving ceiling-mounted downlights, lenses that achieve uniform illuminance at the output aperture as well as at the target. This means that squared-off lenses will produce square spots. In particular, a semicircular lens and a vertical mirror will produce a semicircular spot suitable for gambling tables.
Probabilistic BPRRC: Robust Change Detection against Illumination Changes and Background Movements
NASA Astrophysics Data System (ADS)
Yokoi, Kentaro
This paper presents Probabilistic Bi-polar Radial Reach Correlation (PrBPRRC), a change detection method that is robust against illumination changes and background movements. Most of the traditional change detection methods are robust against either illumination changes or background movements; BPRRC is one of the illumination-robust change detection methods. We introduce a probabilistic background texture model into BPRRC and add the robustness against background movements including foreground invasions such as moving cars, walking people, swaying trees, and falling snow. We show the superiority of PrBPRRC in the environment with illumination changes and background movements by using three public datasets and one private dataset: ATON Highway data, Karlsruhe traffic sequence data, PETS 2007 data, and Walking-in-a-room data.
Modelling of a laser-pumped light source for endoscopic surgery
NASA Astrophysics Data System (ADS)
Nadeau, Valerie J.; Elson, Daniel S.; Hanna, George B.; Neil, Mark A. A.
2008-09-01
A white light source, based on illumination of a yellow phosphor with a fibre-coupled blue-violet diode laser, has been designed and built for use in endoscopic surgery. This narrow light probe can be integrated into a standard laparoscope or inserted into the patient separately via a needle. We present a Monte Carlo model of light scattering and phosphorescence within the phosphor/silicone matrix at the probe tip, and measurements of the colour, intensity, and uniformity of the illumination. Images obtained under illumination with this light source are also presented, demonstrating the improvement in illumination quality over existing endoscopic light sources. This new approach to endoscopic lighting has the advantages of compact design, improved ergonomics, and more uniform illumination in comparison with current technologies.
Illumination control apparatus for compensating solar light
NASA Technical Reports Server (NTRS)
Owens, L. J. (Inventor)
1978-01-01
An illumination control apparatus is presented for supplementing light from solar radiation with light from an artificial light source to compensate for periods of insufficient levels of solar light. The apparatus maintains a desired illumination level within an interior space comprising an artificial light source connected to an electrical power source with a switch means for selectively energizing said light source. An actuator means for controlling the on-off operation of the switch means is connected to a light sensor which responses to the illumination level of the interior space. A limit switch carried adjacent to the actuator limits the movement of the actuator within a predetermined range so as to prevent further movement thereof during detection of erroneous illumination conditions.
Multibeam interferometric illumination as the primary source of resolution in optical microscopy
NASA Astrophysics Data System (ADS)
Ryu, J.; Hong, S. S.; Horn, B. K. P.; Freeman, D. M.; Mermelstein, M. S.
2006-04-01
High-resolution images of a fluorescent target were obtained using a low-resolution optical detector by illuminating the target with interference patterns produced with 31 coherent beams. The beams were arranged in a cone with 78° half angle to produce illumination patterns consistent with a numerical aperture of 0.98. High-resolution images were constructed from low-resolution images taken with 930 different illumination patterns. Results for optical detectors with numerical apertures of 0.1 and 0.2 were similar, demonstrating that the resolution is primarily determined by the illuminator and not by the low-resolution detector. Furthermore, the long working distance, large depth of field, and large field of view of the low-resolution detector are preserved.
Enhancing multi-spot structured illumination microscopy with fluorescence difference
NASA Astrophysics Data System (ADS)
Ward, Edward N.; Torkelsen, Frida H.; Pal, Robert
2018-03-01
Structured illumination microscopy is a super-resolution technique used extensively in biological research. However, this technique is limited in the maximum possible resolution increase. Here we report the results of simulations of a novel enhanced multi-spot structured illumination technique. This method combines the super-resolution technique of difference microscopy with structured illumination deconvolution. Initial results give at minimum a 1.4-fold increase in resolution over conventional structured illumination in a low-noise environment. This new technique also has the potential to be expanded to further enhance axial resolution with three-dimensional difference microscopy. The requirement for precise pattern determination in this technique also led to the development of a new pattern estimation algorithm which proved more efficient and reliable than other methods tested.
Detection of Single Molecules Illuminated by a Light-Emitting Diode
Gerhardt, Ilja; Mai, Lijian; Lamas-Linares, Antía; Kurtsiefer, Christian
2011-01-01
Optical detection and spectroscopy of single molecules has become an indispensable tool in biological imaging and sensing. Its success is based on fluorescence of organic dye molecules under carefully engineered laser illumination. In this paper we demonstrate optical detection of single molecules on a wide-field microscope with an illumination based on a commercially available, green light-emitting diode. The results are directly compared with laser illumination in the same experimental configuration. The setup and the limiting factors, such as light transfer to the sample, spectral filtering and the resulting signal-to-noise ratio are discussed. A theoretical and an experimental approach to estimate these parameters are presented. The results can be adapted to other single emitter and illumination schemes. PMID:22346610
NASA Astrophysics Data System (ADS)
Li, Jun; Fu, Yi-Zhou; Huang, Chuan-Xin; Zhang, Jian-Hua; Jiang, Xue-Yin; Zhang, Zhi-Lin
2016-04-01
This work presents a strategy of nitrogen anion doping to suppress negative gate-bias illumination instability. The electrical performance and negative gate-bias illumination stability of the ZnSnON thin film transistors (TFTs) are investigated. Compared with ZnSnO-TFT, ZnSnON-TFT has a 53% decrease in the threshold voltage shift under negative bias illumination stress and electrical performance also progresses obviously. The stability improvement of ZnSnON-TFT is attributed to the reduction in ionized oxygen vacancy defects and the photodesorption of oxygen-related molecules. It suggests that anion doping can provide an effective solution to the adverse tradeoff between field effect mobility and negative bias illumination stability.
Midwestern Medieval Illuminations Archives.
ERIC Educational Resources Information Center
Purdue Univ., Lafayette, IN. Audio-Visual Center.
This catalog lists the slides of medieval manuscript illuminations available at the Midwestern Medieval Illuminations Archives at the Purdue University Audio-Visual Center. Instructions are provided for ordering slides from the Center. Slide sets are listed by title, with citations including catalog number, rental price, producer/vendor code,…
Identification and Comprehension of Symbolic Exit Signs for Small Transport-Category Airplanes
2014-02-01
8 Phase Two: Self -illuminated Exit Signs...11 Self -illuminated Exit Sign Comprehension ---------------------------------------------------------------------- 12 Automatic...other sign parameters such as stroke width to height, contrast ratios, and self -illumination, fall within those recommended by 14 CFR 25.812(b)(2
USDA-ARS?s Scientific Manuscript database
Structured illumination using sinusoidal patterns has been utilized for optical imaging of biological tissues in biomedical research and, of horticultural products. Implementation of structured-illumination imaging relies on retrieval of amplitude images, which is conventionally achieved by a phase-...
32 CFR 707.10 - Wake illumination light.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 32 National Defense 5 2010-07-01 2010-07-01 false Wake illumination light. 707.10 Section 707.10 National Defense Department of Defense (Continued) DEPARTMENT OF THE NAVY NAVIGATION SPECIAL RULES WITH... display a white spot light located near the stern to illuminate the wake. ...
Investigation of interface property in Al/SiO2/ n-SiC structure with thin gate oxide by illumination
NASA Astrophysics Data System (ADS)
Chang, P. K.; Hwu, J. G.
2017-04-01
The reverse tunneling current of Al/SiO2/ n-SiC structure employing thin gate oxide is introduced to examine the interface property by illumination. The gate current at negative bias decreases under blue LED illumination, yet increases under UV lamp illumination. Light-induced electrons captured by interface states may be emitted after the light sources are off, leading to the recovery of gate currents. Based on transient characteristics of gate current, the extracted trap level is close to the light energy for blue LED, indicating that electron capture induced by lighting may result in the reduction of gate current. Furthermore, bidirectional C- V measurements exhibit a positive voltage shift caused by electron trapping under blue LED illumination, while a negative voltage shift is observed under UV lamp illumination. Distinct trapping and detrapping behaviors can be observed from variations in I- V and C- V curves utilizing different light sources for 4H-SiC MOS capacitors with thin insulators.
Wang, Benquan; Toslak, Devrim; Alam, Minhaj Nur; Chan, R V Paul; Yao, Xincheng
2018-06-08
In conventional fundus photography, trans-pupillary illumination delivers illuminating light to the interior of the eye through the peripheral area of the pupil, and only the central part of the pupil can be used for collecting imaging light. Therefore, the field of view of conventional fundus cameras is limited, and pupil dilation is required for evaluating the retinal periphery which is frequently affected by diabetic retinopathy (DR), retinopathy of prematurity (ROP), and other chorioretinal conditions. We report here a nonmydriatic wide field fundus camera employing trans-pars-planar illumination which delivers illuminating light through the pars plana, an area outside of the pupil. Trans-pars-planar illumination frees the entire pupil for imaging purpose only, and thus wide field fundus photography can be readily achieved with less pupil dilation. For proof-of-concept testing, using all off-the-shelf components a prototype instrument that can achieve 90° fundus view coverage in single-shot fundus images, without the need of pharmacologic pupil dilation was demonstrated.
Chandelier Illumination for Descemet Membrane Endothelial Keratoplasty
Hayashi, Takahiko; Yuda, Kentaro; Tsuchiya, Ayako; Oyakawa, Itaru; Mizuki, Nobuhisa; Kato, Naoko
2017-01-01
Purpose: To describe a simple technique that uses posterior chandelier illumination during Descemet membrane endothelial keratoplasty in cases of severe bullous keratopathy (BK). Methods: Five eyes of 4 patients with advanced BK undergoing Descemet membrane endothelial keratoplasty were retrospectively analyzed. The pupil of the host eye was not treated with mydriatic or miotic agents. The chandelier illuminator was inserted transconjunctivally into the vitreous cavity from the pars plana. Results: In all eyes, BK was secondary to laser iridotomy, which was performed for prevention or treatment of angle closure glaucoma. The implanted graft was clearly confirmed in the anterior chamber using activated chandelier illumination. The graft was immediately attached to the host cornea, with eventual healing of BK in all eyes. No complication involving insertion or removal of the 25-gauge trocar and the chandelier illuminator was observed. No vision-threatening complication was observed in any of the 5 eyes. Conclusions: The chandelier illuminator provided good visibility of the anterior chamber and enhanced the safety of surgery by preventing formation of an inverted graft. PMID:28644235
New reversing design method for LED uniform illumination.
Wang, Kai; Wu, Dan; Qin, Zong; Chen, Fei; Luo, Xiaobing; Liu, Sheng
2011-07-04
In light-emitting diode (LED) applications, it is becoming a big issue that how to optimize light intensity distribution curve (LIDC) and design corresponding optical component to achieve uniform illumination when distance-height ratio (DHR) is given. A new reversing design method is proposed to solve this problem, including design and optimization of LIDC to achieve high uniform illumination and a new algorithm of freeform lens to generate the required LIDC by LED light source. According to this method, two new LED modules integrated with freeform lenses are successfully designed for slim direct-lit LED backlighting with thickness of 10mm, and uniformities of illuminance increase from 0.446 to 0.915 and from 0.155 to 0.887 when DHRs are 2 and 3 respectively. Moreover, the number of new LED modules dramatically decreases to 1/9 of the traditional LED modules while achieving similar uniform illumination in backlighting. Therefore, this new method provides a practical and simple way for optical design of LED uniform illumination when DHR is much larger than 1.
Direct design of achromatic lens for Lambertian sources in collimating illumination
NASA Astrophysics Data System (ADS)
Yin, Peng; Xu, Xiping; Jiang, Zhaoguo; Wang, Hongshu
2017-10-01
Illumination design used to redistribute the spatial energy distribution of light source is a key technique in lighting applications. However, there is still no effective illumination design method for the removing of the chromatic dispersion. What we present here is an achromatic lens design to enhance the efficiency and uniform illumination of white light-emitting diode (LED) with diffractive optical element (DOE). We employ the chromatic aberration value (deg) to measure the degree of chromatic dispersion in illumination systems. Monte Carlo ray tracing simulation results indicate that the chromatic dispersion of the modified achromatic collimator significantly decreases from 0.5 to 0.1 with LED chip size of 1.0mm×1.0mm and simulation efficiency of 90.73%, compared with the traditional collimator. Moreover, with different corrected wavelengths we compared different chromatic aberration values that followed with the changing pupil percent. The achromatic collimator provided an effective way to achieve white LED with low chromatic dispersion at high efficiency and uniform illumination.
Spectrally optimal illuminations for diabetic retinopathy detection in retinal imaging
NASA Astrophysics Data System (ADS)
Bartczak, Piotr; Fält, Pauli; Penttinen, Niko; Ylitepsa, Pasi; Laaksonen, Lauri; Lensu, Lasse; Hauta-Kasari, Markku; Uusitalo, Hannu
2017-04-01
Retinal photography is a standard method for recording retinal diseases for subsequent analysis and diagnosis. However, the currently used white light or red-free retinal imaging does not necessarily provide the best possible visibility of different types of retinal lesions, important when developing diagnostic tools for handheld devices, such as smartphones. Using specifically designed illumination, the visibility and contrast of retinal lesions could be improved. In this study, spectrally optimal illuminations for diabetic retinopathy lesion visualization are implemented using a spectrally tunable light source based on digital micromirror device. The applicability of this method was tested in vivo by taking retinal monochrome images from the eyes of five diabetic volunteers and two non-diabetic control subjects. For comparison to existing methods, we evaluated the contrast of retinal images taken with our method and red-free illumination. The preliminary results show that the use of optimal illuminations improved the contrast of diabetic lesions in retinal images by 30-70%, compared to the traditional red-free illumination imaging.
Jung, Hyunjun; Kang, Hongki; Nam, Yoonkey
2017-06-01
Light-mediated neuromodulation techniques provide great advantages to investigate neuroscience due to its high spatial and temporal resolution. To generate a spatial pattern of neural activity, it is necessary to develop a system for patterned-light illumination to a specific area. Digital micromirror device (DMD) based patterned illumination system have been used for neuromodulation due to its simple configuration and design flexibility. In this paper, we developed a patterned near-infrared (NIR) illumination system for region specific photothermal manipulation of neural activity using NIR-sensitive plasmonic gold nanorods (GNRs). The proposed system had high power transmission efficiency for delivering power density up to 19 W/mm 2 . We used a GNR-coated microelectrode array (MEA) to perform biological experiments using E18 rat hippocampal neurons and showed that it was possible to inhibit neural spiking activity of specific area in neural circuits with the patterned NIR illumination. This patterned NIR illumination system can serve as a promising neuromodulation tool to investigate neuroscience in a wide range of physiological and clinical applications.
Memory color assisted illuminant estimation through pixel clustering
NASA Astrophysics Data System (ADS)
Zhang, Heng; Quan, Shuxue
2010-01-01
The under constrained nature of illuminant estimation determines that in order to resolve the problem, certain assumptions are needed, such as the gray world theory. Including more constraints in this process may help explore the useful information in an image and improve the accuracy of the estimated illuminant, providing that the constraints hold. Based on the observation that most personal images have contents of one or more of the following categories: neutral objects, human beings, sky, and plants, we propose a method for illuminant estimation through the clustering of pixels of gray and three dominant memory colors: skin tone, sky blue, and foliage green. Analysis shows that samples of the above colors cluster around small areas under different illuminants and their characteristics can be used to effectively detect pixels falling into each of the categories. The algorithm requires the knowledge of the spectral sensitivity response of the camera, and a spectral database consisted of the CIE standard illuminants and reflectance or radiance database of samples of the above colors.
Construction and validation of a Tamil logMAR chart.
Varadharajan, Srinivasa; Srinivasan, Krithica; Kumaresan, Brindha
2009-09-01
To design, construct and validate a new Tamil logMAR visual acuity chart based on current recommendations. Ten Tamil letters of equal legibility were identified experimentally and were used in the chart. Two charts, one internally illuminated and one externally illuminated, were constructed for testing at 4 m distance. The repeatability of the two charts was tested. For validation, the two charts were compared with a standard English logMAR chart (ETDRS). When compared to the ETDRS chart, a difference of 0.06 +/- 0.07 and 0.07 +/- 0.07 logMAR was found for the internally and externally illuminated charts respectively. Limits of agreement between the internally illuminated Tamil logMAR chart and ETDRS chart were found to be (-0.08, 0.19), and (-0.07, 0.20) for the externally illuminated chart. The test - retest results showed a difference of 0.02 +/- 0.04 and 0.02 +/- 0.06 logMAR for the internally and externally illuminated charts respectively. Limits of agreement for repeated measurements for the internally illuminated Tamil logMAR chart were found to be (-0.06, 0.10), and (-0.10, 0.14) for the externally illuminated chart. The newly constructed Tamil logMAR charts have good repeatability. The difference in visual acuity scores between the newly constructed Tamil logMAR chart and the standard English logMAR chart was within acceptable limits. This new chart can be used for measuring visual acuity in the literate Tamil population.
Cionni, Robert J; Pei, Ron; Dimalanta, Ramon; Lubeck, David
2015-08-01
To evaluate the intensity and stability of the red reflex produced by ophthalmic surgical microscopes with nearly-collimated versus focused illumination systems and to assess surgeon preference in a simulated surgical setting. This two-part evaluation consisted of postproduction surgical video analysis of red reflex intensity and a microscope use and preference survey completed by 13 experienced cataract surgeons. Survey responses were based on bench testing and experience in a simulated surgical setting. A microscope with nearly-collimated beam illumination and two focused beam microscopes were assessed. Red reflex intensity and stability were greater with the nearly-collimated microscope illumination system. In the bench testing survey, surgeons reported that the red reflex was maintained over significantly greater distances away from pupillary center, and depth of focus was numerically greater with nearly-collimated illumination relative to focused illumination. Most participating surgeons (≥64%) reported a preference for the microscope with nearly-collimated illumination with regard to red reflex stability, depth of focus, visualization, surgical working distance, and perceived patient comfort. The microscope with nearly-collimated illumination produced a more intense and significantly more stable red reflex and was preferred overall by more surgeons. This is the first report of an attempt to quantify red reflex intensity and stability and to evaluate surgically-relevant parameters between microscope systems. The data and methods presented here may provide a basis for future studies attempting to quantify differences between surgical microscopes that may affect surgeon preference and microscope use in ophthalmic surgery.
Kumar, Amit; Ghate, Vinayak; Kim, Min-Jeong; Zhou, Weibiao; Khoo, Gek Hoon; Yuk, Hyun-Gyun
2017-05-01
The objective of this study was to investigate the effect of 460 nm light-emitting diode (LED) on the inactivation of foodborne bacteria. Additionally, the change in the endogenous metabolic profile of LED illuminated cells was analyzed to understand the bacterial response to the LED illumination. Six different species of bacteria (Bacillus cereus, Listeria monocytogenes, Staphylococcus aureus, Escherichia coli O157:H7, Pseudomonas aeruginosa and Salmonella Typhimurium) were illuminated with 460 nm LED to a maximum dose of 4080 J/cm 2 at 4, 10 and 25 °C. Inactivation curves were modeled using Hom model. Metabolic profiling of the non-illuminated and illuminated cells was performed using a Liquid chromatography-mass spectrometry system. Results indicate that the 460 nm LED significantly (p < 0.05) reduced the populations of all six bacterial species. For example, the population of S. aureus reached below detection limit within 7 h. B. cereus was most resistant to photo-inactivation and exhibited about 3-log reduction in 9 h. Metabolic profiling of the illuminated cells indicated that several metabolites e.g. 11-deoxycortisol, actinonin, coformycin, tyramine, chitobiose etc. were regulated during LED illumination. These results elucidate the effectiveness of 460 nm LED against foodborne bacteria and hence, its suitability as a novel antimicrobial control method to ensure food safety. Copyright © 2016 Elsevier Ltd. All rights reserved.
Context-aware tunable office lighting application and user response
NASA Astrophysics Data System (ADS)
Chen, Nancy H.; Nawyn, Jason; Thompson, Maria; Gibbs, Julie; Larson, Kent
2013-09-01
LED light sources having multiple independently controllable color channels allow tuning of both the intensity and color output. Consequently, highly tailored lighting can be applied according to instantaneous user needs and preferences. Besides improving lighting performance, energy use can also be reduced since the brightest illumination is applied only when necessary. In an example application, low activity or vacant areas of a multi-zone office are lit by low power illumination, including colored light options, which can reduce energy consumption to 20-45% of typical full-time, fullbrightness, office-wide illumination. The availability of color also allows communication functions and additional aesthetic design possibilities. To reduce user burden in frequent switching between various illumination settings, an activity recognition sensor network is used to identify selected office activities. The illumination is then adjusted automatically to satisfy the needs of the occupants. A handheld mobile device provides an interactive interface for gathering user feedback regarding impressions and illumination preferences. The activity-triggered queries collect contemporaneous feedback that reduces reliance on memory; immediate previews of illumination options are also provided. Through mobile queries and post-experience interviews, user feedback was gathered regarding automation, colored lighting, and illumination preferences. Overall reaction was indicated by a range of response words such as fun, stimulating, very cool, very pleasant, enjoyed, good, comfortable, satisfactory, fine, energy saving, interesting, curious, dim, cave, isolated, distracting, and unfamiliar. Positive reaction from a meaningful, though not universal, fraction of users indicates reasonable application potential, particularly as personal preferences and control are accommodated.
Structured-illumination reflectance imaging as a new modality for food quality detection
USDA-ARS?s Scientific Manuscript database
Uniform or diffuse illumination is the standard in implementing many different imaging modalities. This form of illumination, however, has some major limitations in acquisition of useful information from food products because reflectance from the food products is non-uniform due to irregular, curved...
DOT National Transportation Integrated Search
2016-03-01
This report is for the first phase of a two-phase research program to develop recommended practices for GDOT for lighting rural roundabouts. Phase I of the study was designed to improve our understanding of the relationship between roundabout illumin...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-26
... Laser Illumination of Aircraft AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice and... collection covers the reporting of unauthorized illumination of aircraft by lasers. DATES: Written comments.... Title: Reporting of Laser Illumination of Aircraft. Form Numbers: Advisory Circular 70-2. Type of Review...
Back-illuminated CCD imager adapted for contrast transfer function measurements thereon
NASA Technical Reports Server (NTRS)
Levine, Peter A. (Inventor)
1987-01-01
Stripe patterns of varying spatial frequency, formed in the top-metalization of a back-illuminated solid-state imager, facilitate on-line measurement of contrast transfer function during wafer-probe testing. The imager may be packaged to allow front-illumination during in-the-field testing after its manufacture.
USDA-ARS?s Scientific Manuscript database
Structured-illumination reflectance imaging (SIRI) provides a new means for enhanced detection of defects in horticultural products. Implementing the technique relies on retrieving amplitude images by illuminating the object with sinusoidal patterns of single spatial frequencies, which, however, are...
30 CFR 56.17001 - Illumination of surface working areas.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Illumination of surface working areas. 56.17001 Section 56.17001 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Illumination...
10 CFR 431.202 - Definitions concerning illuminated exit signs.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Section 431.202 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN... efficiency, water consumption, or water efficiency. Face means an illuminated side of an illuminated exit... batteries, input power demand shall be measured with batteries at full charge. [70 FR 60417, Oct. 18, 2005...
10 CFR 431.202 - Definitions concerning illuminated exit signs.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Section 431.202 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN... efficiency, water consumption, or water efficiency. Face means an illuminated side of an illuminated exit... batteries, input power demand shall be measured with batteries at full charge. [70 FR 60417, Oct. 18, 2005...
10 CFR 431.202 - Definitions concerning illuminated exit signs.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Section 431.202 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN... efficiency, water consumption, or water efficiency. Face means an illuminated side of an illuminated exit... batteries, input power demand shall be measured with batteries at full charge. [70 FR 60417, Oct. 18, 2005...
Adaptive Ambient Illumination Based on Color Harmony Model
NASA Astrophysics Data System (ADS)
Kikuchi, Ayano; Hirai, Keita; Nakaguchi, Toshiya; Tsumura, Norimichi; Miyake, Yoichi
We investigated the relationship between ambient illumination and psychological effect by applying a modified color harmony model. We verified the proposed model by analyzing correlation between psychological value and modified color harmony score. Experimental results showed the possibility to obtain the best color for illumination using this model.
USDA-ARS?s Scientific Manuscript database
In this research, a novel method of fresh bruise detection was developed using a structured illumination reflectance imaging (SIRI) system. The SIRI system projects sinusoidal patterns of illumination onto samples, and image demodulation is then used to recover depth-specific information through var...
Sabatini, Jesse J; Raab, James M; Hann, Ronald K; Damavarapu, Reddy; Klapötke, Thomas M
2012-06-01
The development of perchlorate-free hand-held signal illuminants for the US Army's M195 green star parachute is described. Compared with the perchlorate-containing control, the optimized perchlorate-free illuminants were less sensitive toward various ignition stimuli while offering comparable burn times and visible-light outputs. The results were also important from the perspective of civilian fireworks because the development of perchlorate-free illuminants remains an important objective of the commercial fireworks industry. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
[Light modes and ovulation function in rats in ontogenesis].
Vinogradova, I A; Chernova, I V
2007-01-01
Enhancement of illumination was shown to lead to occurrence of early and more obvious age-dependent changes of ovulation cycle in rats as compared with the same changes in animals staying in conditions of light deprivation or standard illumination. The effect of 24-hour illumination during a year induced more obvious and still earlier changes of the estrus cycle that the effect of natural illumination in the North-West of Russia with its peculiar yearly photo-periodicity (short light day in the autumn-winter period and "white nights" in the spring-summer period).
Optical design applications for enhanced illumination performance
NASA Astrophysics Data System (ADS)
Gilray, Carl; Lewin, Ian
1995-08-01
Nonimaging optical design techniques have been applied in the illumination industry for many years. Recently however, powerful software has been developed which allows accurate simulation and optimization of illumination devices. Wide experience has been obtained in using such design techniques for practical situations. These include automotive lighting where safety is of greatest importance, commercial lighting systems designed for energy efficiency, and numerous specialized applications. This presentation will discuss the performance requirements of a variety of illumination devices. It will further cover design methodology and present a variety of examples of practical applications for enhanced system performance.
Study of chromatic adaptation via neutral white matches on different viewing media.
Zhai, Qiyan; Luo, Ming R
2018-03-19
Two experiments were carried out to study the neutral white and the chromatic adaptation in human vision and color science. After matching neutral whites under different illuminants using both surface and self-luminous colors, the result were used to verify the previous study about the chromatic adaptation. Not all the white illuminants were found neutral even the adaptation time is long. The baseline illuminant of the two-step chromatic adaptation transform was found as the illuminant with the same chromaticity of the neutral white under it and depended on viewing medium in the present study. The results were also used as corresponding colors to derive models of the effective degree of chromatic adaptation, which were found highly associated with the chromaticity of the adapting illuminant.
An inexpensive programmable illumination microscope with active feedback.
Tompkins, Nathan; Fraden, Seth
2016-02-01
We have developed a programmable illumination system capable of tracking and illuminating numerous objects simultaneously using only low-cost and reused optical components. The active feedback control software allows for a closed-loop system that tracks and perturbs objects of interest automatically. Our system uses a static stage where the objects of interest are tracked computationally as they move across the field of view allowing for a large number of simultaneous experiments. An algorithmically determined illumination pattern can be applied anywhere in the field of view with simultaneous imaging and perturbation using different colors of light to enable spatially and temporally structured illumination. Our system consists of a consumer projector, camera, 35-mm camera lens, and a small number of other optical and scaffolding components. The entire apparatus can be assembled for under $4,000.
[Effects of illumination and seed-soaking reagent on seed germination of Solanum nigrum].
Yang, Chuan-Jie; Wei, Shu-He; Zhou, Qi-Xing; Hu, Ya-Hu; Niu, Rong-Cheng
2009-05-01
To explore a rapid seed germination method for hyperaccumulator Solanum nigrum, a germination experiment with different illumination and seed-soaking treatments was conducted in constant temperature box and greenhouse, with filter as burgeon base. Under illumination, the germination rate was about 5 times high of that without illumination (P < 0.05), indicating that illumination was one of the prerequisites for the seed germination of S. nigrum. All test seed-soaking reagents could significantly improve the germination rate of S. nigrum (P < 0.05), with the best effect of H2O2. The seeds treated with H2O2 had the shortest germination time. The germination rate of seeds soaked but without cleaning was 2-3 times as high as that of seeds soaked and cleaned with water.
Rectangular illumination using a secondary optics with cylindrical lens for LED street light.
Chen, Hsi-Chao; Lin, Jun-Yu; Chiu, Hsuan-Yi
2013-02-11
The illumination pattern of an LED street light is required to have a rectangular distribution at a divergence-angle ratio of 7:3 for economical illumination. Hence, research supplying a secondary optics with two cylindrical lenses was different from free-form curvature for rectangular illumination. The analytical solution for curvatures with different ratio rectangles solved this detail by light tracing and boundary conditions. Similarities between the experiments and the simulation for a single LED and a 9-LED module were analyzed by Normalized Cross Correlation (NCC), and the error rate was studied by the Root Mean Square (RMS). The tolerance of position must be kept under ± 0.2 mm in the x, y and z directions to ensure that the relative illumination is over 99%.
Enhancing multi-spot structured illumination microscopy with fluorescence difference
Torkelsen, Frida H.
2018-01-01
Structured illumination microscopy is a super-resolution technique used extensively in biological research. However, this technique is limited in the maximum possible resolution increase. Here we report the results of simulations of a novel enhanced multi-spot structured illumination technique. This method combines the super-resolution technique of difference microscopy with structured illumination deconvolution. Initial results give at minimum a 1.4-fold increase in resolution over conventional structured illumination in a low-noise environment. This new technique also has the potential to be expanded to further enhance axial resolution with three-dimensional difference microscopy. The requirement for precise pattern determination in this technique also led to the development of a new pattern estimation algorithm which proved more efficient and reliable than other methods tested. PMID:29657751
Bosse, Jens B.; Tanneti, Nikhila S.; Hogue, Ian B.; Enquist, Lynn W.
2015-01-01
Dual-color live cell fluorescence microscopy of fast intracellular trafficking processes, such as axonal transport, requires rapid switching of illumination channels. Typical broad-spectrum sources necessitate the use of mechanical filter switching, which introduces delays between acquisition of different fluorescence channels, impeding the interpretation and quantification of highly dynamic processes. Light Emitting Diodes (LEDs), however, allow modulation of excitation light in microseconds. Here we provide a step-by-step protocol to enable any scientist to build a research-grade LED illuminator for live cell microscopy, even without prior experience with electronics or optics. We quantify and compare components, discuss our design considerations, and demonstrate the performance of our LED illuminator by imaging axonal transport of herpes virus particles with high temporal resolution. PMID:26600461
Detection Technique for Artificially Illuminated Objects in the Outer Solar System and Beyond
Loeb, Abraham
2012-01-01
Abstract Existing and planned optical telescopes and surveys can detect artificially illuminated objects, comparable in total brightness to a major terrestrial city, at the outskirts of the Solar System. Orbital parameters of Kuiper belt objects (KBOs) are routinely measured to exquisite precisions of<10−3. Here, we propose to measure the variation of the observed flux F from such objects as a function of their changing orbital distances D. Sunlight-illuminated objects will show a logarithmic slope α ≡ (d log F/d log D)=−4, whereas artificially illuminated objects should exhibit α=−2. The proposed Large Synoptic Survey Telescope (LSST) and other planned surveys will provide superb data and allow measurement of α for thousands of KBOs. If objects with α=−2 are found, follow-up observations could measure their spectra to determine whether they are illuminated by artificial lighting. The search can be extended beyond the Solar System with future generations of telescopes on the ground and in space that would have the capacity to detect phase modulation due to very strong artificial illumination on the nightside of planets as they orbit their parent stars. Key Words: Astrobiology—SETI—Kuiper belt objects—Artificial illumination. Astrobiology 12, 290–294. PMID:22490065
Rohmer, Kai; Buschel, Wolfgang; Dachselt, Raimund; Grosch, Thorsten
2015-12-01
At present, photorealistic augmentation is not yet possible since the computational power of mobile devices is insufficient. Even streaming solutions from stationary PCs cause a latency that affects user interactions considerably. Therefore, we introduce a differential rendering method that allows for a consistent illumination of the inserted virtual objects on mobile devices, avoiding delays. The computation effort is shared between a stationary PC and the mobile devices to make use of the capacities available on both sides. The method is designed such that only a minimum amount of data has to be transferred asynchronously between the participants. This allows for an interactive illumination of virtual objects with a consistent appearance under both temporally and spatially varying real illumination conditions. To describe the complex near-field illumination in an indoor scenario, HDR video cameras are used to capture the illumination from multiple directions. In this way, sources of illumination can be considered that are not directly visible to the mobile device because of occlusions and the limited field of view. While our method focuses on Lambertian materials, we also provide some initial approaches to approximate non-diffuse virtual objects and thereby allow for a wider field of application at nearly the same cost.
Matsuzaki, Jun; Masumori, Masaya; Tange, Takeshi
2007-05-01
Active phototropic bending of non-elongating and radially growing portion of stems (woody stems) has not been previously documented, whereas negative gravitropic bending is well known. We found phototropic bending in woody stems and searched for the underlying mechanism. We inclined 1-year-old Quercus crispula Blume seedlings and unilaterally illuminated them from a horizontal direction perpendicular to ('normal' illumination) or parallel to ('parallel' illumination) the inclination azimuth. With normal illumination, active phototropic bending and xylem formation could be evaluated separately from the negative gravitropic response and vertical deflection resulting from the weight of the seedlings. One-year-old stems with normal illumination bent significantly, with asymmetrical xylem formation towards the illuminated upper surface and side of the stem, whereas those with parallel illumination showed non-significant lateral bending, with asymmetrical xylem formation only on the upper side. A mechanical model was built on the assumption that a bending moment resulted from the asymmetrical xylem formation during phototropic bending of the woody stems. The model fitted the relationship between the observed spatial distributions of the xylem and the observed lateral bending, and thus supported the hypothesis that phototropic bending of woody stems results from asymmetrical xylem formation, as such occurs during gravitropism.
Lai, Jinxing; Qiu, Junling; Chen, Jianxun; Wang, Yaqiong; Fan, Haobo
2014-01-01
Because of the particularity of the environment in the tunnel, the rational tunnel illumination system should be developed, so as to optimize the tunnel environment. Considering the high cost of traditional tunnel illumination system with high-pressure sodium (HPS) lamps as well as the effect of a single light source on tunnel entrance, the energy-saving illumination system with HPS lamps and LEDs combined illumination in road tunnel, which could make full use of these two kinds of lamps, was proposed. The wireless intelligent control system based on HPS lamps and LEDs combined illumination and microcontrol unit (MCU) Si1000 wireless communication technology was designed. And the remote monitoring, wireless communication, and PWM dimming module of this system were designed emphatically. Intensity detector and vehicle flow detector can be configured in wireless intelligent control system, which gather the information to the master control unit, and then the information is sent to the monitoring center through the Ethernet. The control strategies are got by the monitoring center according to the calculated results, and the control unit wirelessly sends parameters to lamps, which adjust the luminance of each segment of the tunnel and realize the wireless intelligent control of combined illumination in road tunnel. PMID:25587266
Natural light illumination system.
Whang, Allen Jong-Woei; Chen, Yi-Yung; Yang, Shu-Hua; Pan, Po-Hsuan; Chou, Kao-Hsu; Lee, Yu-Chi; Lee, Zong-Yi; Chen, Chi-An; Chen, Cheng-Nan
2010-12-10
In recent years, green energy has undergone a lot of development and has been the subject of many applications. Many research studies have focused on illumination with sunlight as a means of saving energy and creating healthy lighting. Natural light illumination systems have collecting, transmitting, and lighting elements. Today, most daylight collectors use dynamic concentrators; these include Sun tracking systems. However, this design is too expensive to be cost effective. To create a low-cost collector that can be easily installed on a large building, we have designed a static concentrator, which is prismatic and cascadable, to collect sunlight for indoor illumination. The transmission component uses a large number of optical fibers. Because optical fibers are expensive, this means that most of the cost for the system will be related to transmission. In this paper, we also use a prismatic structure to design an optical coupler for coupling n to 1. With the n-to-1 coupler, the number of optical fibers necessary can be greatly reduced. Although this new natural light illumination system can effectively guide collected sunlight and send it to the basement or to other indoor places for healthy lighting, previously there has been no way to manage the collected sunlight when lighting was not desired. To solve this problem, we have designed an optical switch and a beam splitter to control and separate the transmitted light. When replacing traditional sources, the lighting should have similar characteristics, such as intensity distribution and geometric parameters, to those of traditional artificial sources. We have designed, simulated, and optimized an illumination lightpipe with a dot pattern to redistribute the collected sunlight from the natural light illumination system such that it equals the qualities of a traditional lighting system. We also provide an active lighting module that provides lighting from the natural light illumination system or LED auxiliary sources, depending on circumstances. The system is controlled by a light detector. We used optical simulation tools to design and simulate the efficiency of the active module. Finally, we used the natural light illumination system to provide natural illumination for a traffic tunnel. This system will provide a great number of benefits for the people who use it.
Back-illuminate fiber system research for multi-object fiber spectroscopic telescope
NASA Astrophysics Data System (ADS)
Zhou, Zengxiang; Liu, Zhigang; Hu, Hongzhuan; Wang, Jianping; Zhai, Chao; Chu, Jiaru
2016-07-01
In the telescope observation, the position of fiber will highly influence the spectra efficient input in the fiber to the spectrograph. When the fibers were back illuminated on the spectra end, they would export light on the positioner end, so the CCD cameras could capture the photo of fiber tip position covered the focal plane, calculates the precise position information by light centroid method and feeds back to control system. A set of fiber back illuminated system was developed which combined to the low revolution spectro instruments in LAMOST. It could provide uniform light output to the fibers, meet the requirements for the CCD camera measurement. The paper was introduced the back illuminated system design and different test for the light resource. After optimization, the effect illuminated system could compare with the integrating sphere, meet the conditions of fiber position measurement.Using parallel controlled fiber positioner as the spectroscopic receiver is an efficiency observation system for spectra survey, has been used in LAMOST recently, and will be proposed in CFHT and rebuilt telescope Mayall. In the telescope observation, the position of fiber will highly influence the spectra efficient input in the fiber to the spectrograph. When the fibers were back illuminated on the spectra end, they would export light on the positioner end, so the CCD cameras could capture the photo of fiber tip position covered the focal plane, calculates the precise position information by light centroid method and feeds back to control system. After many years on these research, the back illuminated fiber measurement was the best method to acquire the precision position of fibers. In LAMOST, a set of fiber back illuminated system was developed which combined to the low revolution spectro instruments in LAMOST. It could provide uniform light output to the fibers, meet the requirements for the CCD camera measurement and was controlled by high-level observation system which could shut down during the telescope observation. The paper was introduced the back illuminated system design and different test for the light resource. After optimization, the effect illuminated system could compare the integrating sphere, meet the conditions of fiber position measurement.
NASA Astrophysics Data System (ADS)
Ma, Chen; Cheng, Dewen; Xu, Chen; Wang, Yongtian
2014-11-01
Fundus camera is a complex optical system for retinal photography, involving illumination and imaging of the retina. Stray light is one of the most significant problems of fundus camera because the retina is so minimally reflective that back reflections from the cornea and any other optical surface are likely to be significantly greater than the light reflected from the retina. To provide maximum illumination to the retina while eliminating back reflections, a novel design of illumination system used in portable fundus camera is proposed. Internal illumination, in which eyepiece is shared by both the illumination system and the imaging system but the condenser and the objective are separated by a beam splitter, is adopted for its high efficiency. To eliminate the strong stray light caused by corneal center and make full use of light energy, the annular stop in conventional illumination systems is replaced by a fiber-coupled, ring-shaped light source that forms an annular beam. Parameters including size and divergence angle of the light source are specially designed. To weaken the stray light, a polarized light source is used, and an analyzer plate is placed after beam splitter in the imaging system. Simulation results show that the illumination uniformity at the fundus exceeds 90%, and the stray light is within 1%. Finally, a proof-of-concept prototype is developed and retinal photos of an ophthalmophantom are captured. The experimental results show that ghost images and stray light have been greatly reduced to a level that professional diagnostic will not be interfered with.
NASA Astrophysics Data System (ADS)
Batra, V.; Kotru, S.
2017-12-01
We report the effects of illumination on the ferroelectric and photovoltaic properties of the Pb0.95La0.05Zr0.54Ti0.46O3 (PLZT) thin film based asymmetric metal/ferroelectric/metal capacitor structure, using Au as a top electrode and Pt as a bottom electrode. Conductive-AFM (atomic force microscopy) measurements demonstrate the evolution of charge carriers in PLZT films on illumination. The capacitance-voltage, the polarization-electric field, and the leakage current-voltage characteristics of the asymmetric Au/PLZT/Pt capacitor are discussed under dark and illuminated conditions. The light generates charge carriers in the film, which increase the coercive field and net remnant polarization and decrease the capacitance. The leakage current of the capacitor increases by an order of magnitude upon illumination. The leakage current data analyzed to study the conduction mechanism shows that the capacitor structure follows the Schottky emission "1/4" law. The illuminated current density-voltage curve of the capacitor shows non-zero photovoltaic parameters. An open circuit voltage (Voc) of -0.19 V and a short circuit current density (Jsc) of 1.48 μA/cm2 were obtained in an unpoled film. However, after positive poling, the illuminated curve shifts towards a higher voltage value resulting in a Voc of -0.93 V. After negative poling, the curve shows no change in the Voc value. For both poling directions, the Jsc values decrease. The photocurrent in the capacitor shows a linear variation with the incident illumination intensity.
Cionni, Robert J.; Pei, Ron; Dimalanta, Ramon; Lubeck, David
2015-01-01
Purpose To evaluate the intensity and stability of the red reflex produced by ophthalmic surgical microscopes with nearly-collimated versus focused illumination systems and to assess surgeon preference in a simulated surgical setting. Methods This two-part evaluation consisted of postproduction surgical video analysis of red reflex intensity and a microscope use and preference survey completed by 13 experienced cataract surgeons. Survey responses were based on bench testing and experience in a simulated surgical setting. A microscope with nearly-collimated beam illumination and two focused beam microscopes were assessed. Results Red reflex intensity and stability were greater with the nearly-collimated microscope illumination system. In the bench testing survey, surgeons reported that the red reflex was maintained over significantly greater distances away from pupillary center, and depth of focus was numerically greater with nearly-collimated illumination relative to focused illumination. Most participating surgeons (≥64%) reported a preference for the microscope with nearly-collimated illumination with regard to red reflex stability, depth of focus, visualization, surgical working distance, and perceived patient comfort. Conclusions The microscope with nearly-collimated illumination produced a more intense and significantly more stable red reflex and was preferred overall by more surgeons. Translational Relevance This is the first report of an attempt to quantify red reflex intensity and stability and to evaluate surgically-relevant parameters between microscope systems. The data and methods presented here may provide a basis for future studies attempting to quantify differences between surgical microscopes that may affect surgeon preference and microscope use in ophthalmic surgery. PMID:26290778
Kim, Min-Jeong; Bang, Woo Suk; Yuk, Hyun-Gyun
2017-04-01
This study evaluated the antibacterial effect of 405 ± 5 nm light emitting diode (LED) illumination against four Salmonella serovars on fresh-cut papaya and on fruit quality at various storage temperatures. To determine the antibacterial mechanism of LED illumination at 0.9 kJ/cm 2 , oxidative damage to DNA and membrane lipids of Salmonella in phosphate-buffered saline solution was measured. The populations of Salmonella on cut fruits were significantly (P < 0.05) reduced by 0.3-1.3 log CFU/cm 2 at chilling temperatures following LED illumination for 36-48 h (1.3-1.7 kJ/cm 2 ). However, at room temperature, bacterial populations increased rapidly to 6.3-7.0 log CFU/cm 2 following LED illumination for 24 h (0.9 kJ/cm 2 ), which was approximately 1.0 log lower than the number of colonies on non-illuminated fruits. Levels of bacterial DNA oxidation significantly increased, whereas lipid peroxidation in bacterial membrane was not observed, suggesting that DNA oxidation contributes to photodynamic inactivation by LED illumination. LED illumination did not adversely affect the physicochemical and nutritional qualities of cut papaya, regardless of storage temperature. These results indicate that a food chiller equipped with 405 ± 5 nm LEDs can preserve fresh-cut papayas in retail stores without deterioration, minimizing the risk of salmonellosis. Copyright © 2016 Elsevier Ltd. All rights reserved.
Gray-world-assumption-based illuminant color estimation using color gamuts with high and low chroma
NASA Astrophysics Data System (ADS)
Kawamura, Harumi; Yonemura, Shunichi; Ohya, Jun; Kojima, Akira
2013-02-01
A new approach is proposed for estimating illuminant colors from color images under an unknown scene illuminant. The approach is based on a combination of a gray-world-assumption-based illuminant color estimation method and a method using color gamuts. The former method, which is one we had previously proposed, improved on the original method that hypothesizes that the average of all the object colors in a scene is achromatic. Since the original method estimates scene illuminant colors by calculating the average of all the image pixel values, its estimations are incorrect when certain image colors are dominant. Our previous method improves on it by choosing several colors on the basis of an opponent-color property, which is that the average color of opponent colors is achromatic, instead of using all colors. However, it cannot estimate illuminant colors when there are only a few image colors or when the image colors are unevenly distributed in local areas in the color space. The approach we propose in this paper combines our previous method and one using high chroma and low chroma gamuts, which makes it possible to find colors that satisfy the gray world assumption. High chroma gamuts are used for adding appropriate colors to the original image and low chroma gamuts are used for narrowing down illuminant color possibilities. Experimental results obtained using actual images show that even if the image colors are localized in a certain area in the color space, the illuminant colors are accurately estimated, with smaller estimation error average than that generated in the conventional method.
Light-Regulated Electrochemical Sensor Array for Efficiently Discriminating Hazardous Gases.
Liang, Hongqiu; Zhang, Xin; Sun, Huihui; Jin, Han; Zhang, Xiaowei; Jin, Qinghui; Zou, Jie; Haick, Hossam; Jian, Jiawen
2017-10-27
Inadequate detection limit and unsatisfactory discrimination features remain the challenging issues for the widely applied electrochemical gas sensors. Quite recently, we confirmed that light-regulated electrochemical reaction significantly enhanced the electrocatalytic activity, and thereby can potentially extend the detection limit to the parts per billion (ppb) level. Nevertheless, impact of the light-regulated electrochemical reaction on response selectivity has been discussed less. Herein, we systematically report on the effect of illumination on discrimination features via design and fabrication of a light-regulated electrochemical sensor array. Upon illumination (light on), response signal to the examined gases (C 3 H 6 , NO, and CO) is selectively enhanced, resulting in the sensor array demonstrating disparate response patterns when compared with that of the sensor array operated at light off. Through processing all the response patterns derived from both light on and light off with a pattern recognition algorithm, a satisfactory discrimination feature is observed. In contrast, apparent mutual interference between NO and CO is found when the sensor array is solely operated without illumination. The impact mechanism of the illumination is studied and it is deduced that the effect of the illumination on the discriminating features can be mainly attributed to the competition of electrocatalytic activity and gas-phase reactivity. If the enhanced electrocatalytic activity (to specific gas) dominates the whole sensing progress, enhancements in the corresponding response signal would be observed upon illumination. Otherwise, illumination gives a negligible impact. Hence, the response signal to part of the examined gases is selectively enhanced by illumination. Conclusively, light-regulated electrochemical reaction would provide an efficient approach to designing future smart sensing devices.
Illuminating Chaucer through Poetry, Manuscript Illuminations, and a Critical Rap Album
ERIC Educational Resources Information Center
Lynch, Tom Liam
2007-01-01
Drawing connections between Chaucer, Eminem, and social issues, New York City high school teacher Tom Liam Lynch helped students become familiar with "The Canterbury Tales." Students wrote poems of rhymed couplets about today's social and political issues, created illuminated manuscripts, and recorded a rap CD. A book and album were…
USDA-ARS?s Scientific Manuscript database
A scalable and modular LED illumination dome for microscopic scientific photography is described and illustrated, and methods for constructing such a dome are detailed. Dome illumination for insect specimens has become standard practice across the field of insect systematics, but many dome designs ...
Evaluation of Particle Image Velocimetry Measurement Using Multi-wavelength Illumination
NASA Astrophysics Data System (ADS)
Lai, HC; Chew, TF; Razak, NA
2018-05-01
In past decades, particle image velocimetry (PIV) has been widely used in measuring fluid flow and a lot of researches have been done to improve the PIV technique. Many researches are conducted on high power light emitting diode (HPLED) to replace the traditional laser illumination system in PIV. As an extended work to the research in PIV illumination system, two high power light emitting diodes (HPLED) with different wavelength are introduced as PIV illumination system. The objective of this research is using dual colours LED to directly replace laser as illumination system in order for a single frame to be captured by a normal camera instead of a high speed camera. Dual colours HPLEDs PIV are capable with single frame double pulses mode which able to plot the velocity vector of the particles after correlation. An illumination system is designed and fabricated and evaluated by measuring water flow in a small tank. The results indicates that HPLEDs promises a few advantages in terms of cost, safety and performance. It has a high potential to be develop into an alternative for PIV in the near future.
Coaxial fundus camera for opthalmology
NASA Astrophysics Data System (ADS)
de Matos, Luciana; Castro, Guilherme; Castro Neto, Jarbas C.
2015-09-01
A Fundus Camera for ophthalmology is a high definition device which needs to meet low light illumination of the human retina, high resolution in the retina and reflection free image1. Those constraints make its optical design very sophisticated, but the most difficult to comply with is the reflection free illumination and the final alignment due to the high number of non coaxial optical components in the system. Reflection of the illumination, both in the objective and at the cornea, mask image quality, and a poor alignment make the sophisticated optical design useless. In this work we developed a totally axial optical system for a non-midriatic Fundus Camera. The illumination is performed by a LED ring, coaxial with the optical system and composed of IR of visible LEDs. The illumination ring is projected by the objective lens in the cornea. The Objective, LED illuminator, CCD lens are coaxial making the final alignment easily to perform. The CCD + capture lens module is a CCTV camera with autofocus and Zoom built in, added to a 175 mm focal length doublet corrected for infinity, making the system easily operated and very compact.
Effects of illumination and packaging on non-heme iron and color attributes of sliced ham.
Li, H; Li, C B; Xu, X L; Zhou, G H
2012-08-01
This study was designed to investigate effects of illumination and packaging on color of cooked cured sliced ham during refrigeration, and the possibility of decomposition of nitrosylheme under light and oxygen exposure. Three illumination levels and three packaging films with different oxygen transmission rates (OTRs) were used in two separate experiments during 35 days storage, and pH value, a* value, nitrosylheme, residual nitrite and non-heme iron were evaluated. Packaging OTRs had significant effects (P<0.01) on a* value, but illumination level and packaging OTR did not affect (P>0.05) nitrosylheme concentration during storage. For both groups, storage time had a significant effect (P<0.01) on a* value and nitrosylheme. Negative relationships between nitrosylheme and nitrite in the illumination group, and between nitrosylheme and non-heme iron in the packaging group were observed. Therefore, illumination level and packaging OTR had limited effects on overall pigment stability, but more discoloration and loss of redness occurred on the surface of products. Copyright © 2012 Elsevier Ltd. All rights reserved.
Museum lighting: Why are some illuminants preferred?
NASA Astrophysics Data System (ADS)
Scuello, Michael; Abramov, Israel; Gordon, James; Weintraub, Steven
2004-02-01
We had shown earlier that viewers prefer to look at artworks under illuminants of ~3600 K. In the latest paper we tested the hypothesis that the preferred illuminant is one that appears neither warm nor cool and repeated the settings at each of four illuminances to test the stability of the findings. Observers looked at a neutral white reflectance standard hung on a matte-gray wall lit by overhead banks of lamps whose combined value could be adjusted continuously between 3000 and 4400 K while illuminance was kept constant. Illuminance ranged from 50 to 2000 lux. Observers adjusted color temperature until they were satisfied that the standard looked neither warm nor cool. The mean for a group of eight observers was approximately 3700, independent of intensity; this corresponds to a dominant wavelength of ~580 nm. In a separate study four observers scaled the apparent warmth or coolness of flashes of equiluminant monochromatic lights; the warm-cool transition was between 560 and 580 nm; warmness was completely predicted by the perceived redness of each light as derived from hue and saturation scaling functions from the same group.
Chang, Chia-Yuan; Lin, Cheng-Han; Lin, Chun-Yu; Sie, Yong-Da; Hu, Yvonne Yuling; Tsai, Sheng-Feng; Chen, Shean-Jen
2018-01-01
A developed temporal focusing-based multiphoton excitation microscope (TFMPEM) has a digital micromirror device (DMD) which is adopted not only as a blazed grating for light spatial dispersion but also for patterned illumination simultaneously. Herein, the TFMPEM has been extended to implement spatially modulated illumination at structured frequency and orientation to increase the beam coverage at the back-focal aperture of the objective lens. The axial excitation confinement (AEC) of TFMPEM can be condensed from 3.0 μm to 1.5 μm for a 50 % improvement. By using the TFMPEM with HiLo technique as two structured illuminations at the same spatial frequency but different orientation, reconstructed biotissue images according to the condensed AEC structured illumination are shown obviously superior in contrast and better scattering suppression. Picture: TPEF images of the eosin-stained mouse cerebellar cortex by conventional TFMPEM (left), and the TFMPEM with HiLo technique as 1.09 μm -1 spatially modulated illumination at 90° (center) and 0° (right) orientations. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Jung, Hyunjun; Kang, Hongki; Nam, Yoonkey
2017-01-01
Light-mediated neuromodulation techniques provide great advantages to investigate neuroscience due to its high spatial and temporal resolution. To generate a spatial pattern of neural activity, it is necessary to develop a system for patterned-light illumination to a specific area. Digital micromirror device (DMD) based patterned illumination system have been used for neuromodulation due to its simple configuration and design flexibility. In this paper, we developed a patterned near-infrared (NIR) illumination system for region specific photothermal manipulation of neural activity using NIR-sensitive plasmonic gold nanorods (GNRs). The proposed system had high power transmission efficiency for delivering power density up to 19 W/mm2. We used a GNR-coated microelectrode array (MEA) to perform biological experiments using E18 rat hippocampal neurons and showed that it was possible to inhibit neural spiking activity of specific area in neural circuits with the patterned NIR illumination. This patterned NIR illumination system can serve as a promising neuromodulation tool to investigate neuroscience in a wide range of physiological and clinical applications. PMID:28663912
Colour perception with changes in levels of illumination
NASA Astrophysics Data System (ADS)
Baah, Kwame F.; Green, Phil; Pointer, Michael
2012-01-01
The perceived colour of a stimulus depends on the conditions under which it is viewed. For colours employed as an important cue or identifier, such as signage and brand colours, colour reproduction tolerances are critically important. Typically, such stimuli would be judged using a known level of illumination but, in the target environment, the level of illumination used to view the samples may be entirely different. The effect of changes in the viewing condition on the perceptibility and acceptability of small colour differences should be understood when such tolerances and associated viewing conditions, are specified. A series of psychophysical experiments was conducted to determine whether changes in illumination level significantly alter acceptability and perceptibility thresholds of uniform colour stimuli. It was found that perceived colour discrimination thresholds varied by up to 2.0 ΔE00. For the perceptual correlate of hue however, this value could be of significance if the accepted error of colour difference was at the threshold, thereby yielding the possibility of rejection with changes in illumination level. Lightness and chroma on the other hand, exhibited greater tolerance and were less likely to be rejected with illuminance changes.
Detection technique for artificially illuminated objects in the outer solar system and beyond.
Loeb, Abraham; Turner, Edwin L
2012-04-01
Existing and planned optical telescopes and surveys can detect artificially illuminated objects, comparable in total brightness to a major terrestrial city, at the outskirts of the Solar System. Orbital parameters of Kuiper belt objects (KBOs) are routinely measured to exquisite precisions of<10(-3). Here, we propose to measure the variation of the observed flux F from such objects as a function of their changing orbital distances D. Sunlight-illuminated objects will show a logarithmic slope α ≡ (d log F/d log D)=-4, whereas artificially illuminated objects should exhibit α=-2. The proposed Large Synoptic Survey Telescope (LSST) and other planned surveys will provide superb data and allow measurement of α for thousands of KBOs. If objects with α=-2 are found, follow-up observations could measure their spectra to determine whether they are illuminated by artificial lighting. The search can be extended beyond the Solar System with future generations of telescopes on the ground and in space that would have the capacity to detect phase modulation due to very strong artificial illumination on the nightside of planets as they orbit their parent stars.
Improving the uniformity of luminous system in radial imaging capsule endoscope system
NASA Astrophysics Data System (ADS)
Ou-Yang, Mang; Jeng, Wei-De
2013-02-01
This study concerns the illumination system in a radial imaging capsule endoscope (RICE). Uniformly illuminating the object is difficult because the intensity of the light from the light emitting diodes (LEDs) varies with angular displacement. When light is emitted from the surface of the LED, it first encounters the cone mirror, from which it is reflected, before directly passing through the lenses and complementary metal oxide semiconductor (CMOS) sensor. The light that is strongly reflected from the transparent view window (TVW) propagates again to the cone mirror, to be reflected and to pass through the lenses and CMOS sensor. The above two phenomena cause overblooming on the image plane. Overblooming causes nonuniform illumination on the image plane and consequently reduced image quality. In this work, optical design software was utilized to construct a photometric model for the optimal design of the LED illumination system. Based on the original RICE model, this paper proposes an optimal design to improve the uniformity of the illumination. The illumination uniformity in the RICE is increased from its original value of 0.128 to 0.69, greatly improving light uniformity.
Reticle stage based linear dosimeter
Berger, Kurt W [Livermore, CA
2007-03-27
A detector to measure EUV intensity employs a linear array of photodiodes. The detector is particularly suited for photolithography systems that includes: (i) a ringfield camera; (ii) a source of radiation; (iii) a condenser for processing radiation from the source of radiation to produce a ringfield illumination field for illuminating a mask; (iv) a reticle that is positioned at the ringfield camera's object plane and from which a reticle image in the form of an intensity profile is reflected into the entrance pupil of the ringfield camera, wherein the reticle moves in a direction that is transverse to the length of the ringfield illumination field that illuminates the reticle; (v) detector for measuring the entire intensity along the length of the ringfield illumination field that is projected onto the reticle; and (vi) a wafer onto which the reticle imaged is projected from the ringfield camera.
Reticle stage based linear dosimeter
Berger, Kurt W.
2005-06-14
A detector to measure EUV intensity employs a linear array of photodiodes. The detector is particularly suited for photolithography systems that includes: (i) a ringfield camera; (ii) a source of radiation; (iii) a condenser for processing radiation from the source of radiation to produce a ringfield illumination field for illuminating a mask; (iv) a reticle that is positioned at the ringfield camera's object plane and from which a reticle image in the form of an intensity profile is reflected into the entrance pupil of the ringfield camera, wherein the reticle moves in a direction that is transverse to the length of the ringfield illumination field that illuminates the reticle; (v) detector for measuring the entire intensity along the length of the ringfield illumination field that is projected onto the reticle; and (vi) a wafer onto which the reticle imaged is projected from the ringfield camera.
An inexpensive programmable illumination microscope with active feedback
Tompkins, Nathan; Fraden, Seth
2016-01-01
We have developed a programmable illumination system capable of tracking and illuminating numerous objects simultaneously using only low-cost and reused optical components. The active feedback control software allows for a closed-loop system that tracks and perturbs objects of interest automatically. Our system uses a static stage where the objects of interest are tracked computationally as they move across the field of view allowing for a large number of simultaneous experiments. An algorithmically determined illumination pattern can be applied anywhere in the field of view with simultaneous imaging and perturbation using different colors of light to enable spatially and temporally structured illumination. Our system consists of a consumer projector, camera, 35-mm camera lens, and a small number of other optical and scaffolding components. The entire apparatus can be assembled for under $4,000. PMID:27642182
Li, Y; Kinoshita, H; Watanabe, T; Irie, S; Shirayone, S; Okazaki, S
2000-07-01
A scanning critical illumination system is designed to couple a synchrotron radiation source to a three-aspherical-mirror imaging system for extreme ultraviolet lithography. A static illumination area of H x V = 8 mm x 3 mm (where H is horizontal and V is vertical) can be obtained. Uniform intensity distribution and a large ring field of H x V = 150 mm x 3 mm can be achieved by scanning of the mirror of the condenser. The coherence factor (sigma) of this illumination system is approximately 0.6, with the same beam divergence in both the horizontal and the vertical directions. We describe the performance of the imaging optics at sigma = 0.6 to confirm that the illumination optics can meet the requirements for three-aspherical-mirror imaging optics with a feature size of 0.06 microm.
Active illumination using a digital micromirror device for quantitative phase imaging.
Shin, Seungwoo; Kim, Kyoohyun; Yoon, Jonghee; Park, YongKeun
2015-11-15
We present a powerful and cost-effective method for active illumination using a digital micromirror device (DMD) for quantitative phase-imaging techniques. Displaying binary illumination patterns on a DMD with appropriate spatial filtering, plane waves with various illumination angles are generated and impinged onto a sample. Complex optical fields of the sample obtained with various incident angles are then measured via Mach-Zehnder interferometry, from which a high-resolution 2D synthetic aperture phase image and a 3D refractive index tomogram of the sample are reconstructed. We demonstrate the fast and stable illumination-control capability of the proposed method by imaging colloidal spheres and biological cells. The capability of high-speed optical diffraction tomography is also demonstrated by measuring 3D Brownian motion of colloidal particles with the tomogram acquisition rate of 100 Hz.
NASA Astrophysics Data System (ADS)
Ando, Yoriko; Sawahata, Hirohito; Kawano, Takeshi; Koida, Kowa; Numano, Rika
2018-02-01
Bundled fiber optics allow in vivo imaging at deep sites in a body. The intrinsic optical contrast detects detailed structures in blood vessels and organs. We developed a bundled-fiber-coupled endomicroscope, enabling stereoscopic three-dimensional (3-D) reflectance imaging with a multipositional illumination scheme. Two illumination sites were attached to obtain reflectance images with left and right illumination. Depth was estimated by the horizontal disparity between the two images under alternative illuminations and was calibrated by the targets with known depths. This depth reconstruction was applied to an animal model to obtain the 3-D structure of blood vessels of the cerebral cortex (Cereb cortex) and preputial gland (Pre gla). The 3-D endomicroscope could be instrumental to microlevel reflectance imaging, improving the precision in subjective depth perception, spatial orientation, and identification of anatomical structures.
The possible ocular hazards of LED dental illumination applications.
Stamatacos, Catherine; Harrison, Janet L
2014-04-01
The use of high-intensity illumination via Light-Emitting Diode (LED) headlamps is gaining in popularity with dentists and student dentists. Practitioners are using LED headlamps together with magnifying loupes, overhead LED illumination and fiber-optic dental handpieces for long periods of time. Although most manufacturers of these LED illuminators advertise that their devices emit "white" light, these still consist of two spectral bands - the blue spectral band, with its peak at 445 nm, and the green with its peak at 555 nm. While manufacturers suggest that their devices emit "white" light, spectral components of LED lights from different companies are significantly different. Dental headlamp manufacturers strive to create a white LED, and they advertise that this type of light emitted from their product offers bright white-light illumination. However, the manufacturing of a white LED light is done through selection of a white LED-type based on the peak blue strength in combination with the green peak strength and thus creating a beam-forming optic, which determines the beam quality. Some LED illuminators have a strong blue-light component versus the green-light component. Blue-light is highly energized and is close in the color spectrum to ultraviolet-light. The hazards of retinal damage with the use of high-intensity blue-lights has been well-documented. There is limited research regarding the possible ocular hazards of usage of high-intensity illuminating LED devices. Furthermore, the authors have found little research, standards, or guidelines examining the possible safety issues regarding the unique dental practice setting consisting of the combined use of LED illumination systems. Another unexamined component is the effect of high-intensity light reflective glare and magnification back to the practitioner's eyes due to the use of water during dental procedures. Based on the result of Dr. Janet Harrison's observations of beginning dental students in a laboratory setting, the aim of this review is to raise awareness of the potential risk for eye damage when singular or combinations of LED illumination are used.
The possible ocular hazards of LED dental illumination applications.
Stamatacos, Catherine; Harrison, Janet L
2013-01-01
The use of high-intensity illumination via Light-Emitting Diode (LED) headlamps is gaining in popularity with dentists and student dentists. Practitioners are using LED headlamps together with magnifying loupes, overhead LED illumination and fiber-optic dental handpieces for long periods of time. Although most manufacturers of these LED illuminators advertise that their devices emit "white" light, these still consist of two spectral bands--the blue spectral band, with its peak at 445 nm, and the green with its peak at 555 nm. While manufacturers suggest that their devices emit "white" light, spectral components of LED lights from different companies are significantly different. Dental headlamp manufacturers strive to create a white LED, and they advertise that this type of light emitted from their product offers bright white-light illumination. However, the manufacturing of a white LED light is done through selection of a white LED-type based on the peak blue strength in combination with the green peak strength and thus creating a beam-forming optic, which determines the beam quality. Some LED illuminators have a strong blue-light component versus the green-light component. Blue-light is highly energized and is close in the color spectrum to ultraviolet-light. The hazards of retinal damage with the use of high-intensity blue-lights has been well-documented. There is limited research regarding the possible ocular hazards of usage of high-intensity illuminating LED devices. Furthermore, the authors have found little research, standards, or guidelines examining the possible safety issues regarding the unique dental practice setting consisting of the combined use of LED illumination systems. Another unexamined component is the effect of high-intensity light reflective glare and magnification back to the practitioner's eyes due to the use of water during dental procedures. Based on the result of Dr. Janet Harrison's observations of beginning dental students in a laboratory setting, the aim of this review is to raise awareness of the potential risk for eye damage when singular or combinations of LED illumination are used.
Laryngoscope illuminance in a tertiary children's hospital: implications for quality laryngoscopy.
Volsky, Peter G; Murphy, Michael K; Darrow, David H
2014-07-01
Laryngoscopes are used by otolaryngologists in a variety of hospital emergency and critical care settings. However, only rarely have quality-related aspects of laryngoscope function and application been studied. To compare the illuminance of laryngoscopes commonly used in a hospital setting to established standards and to assess the potential effects of maintenance practices on laryngoscope illuminance. Observational study of laryngoscope light output and cross-sectional survey of individuals charged with laryngoscope maintenance in a tertiary care children's hospital. Illuminance was chosen as the unit of measurement (lux). Laryngoscopes in the operating room, emergency department, and pediatric intensive care unit were tested according to a standard technique. Illuminance standards for laryngoscopes, published by the International Organization for Standardization (ISO) (500 lux) and in the medical literature (867 lux) were used as benchmarks. Mean laryngoscope illuminance by type of laryngoscope and light source and percentage of laryngoscopes with illuminance below established standards as well as nonfunctioning units. Maintenance practices were evaluated as a secondary outcome. A total of 319 laryngoscopes were tested; 283 were incandescent bulb units used by anesthesiologists, emergency physicians, and intensivists and 36 were xenon light units used by otolaryngologists. Mean (SD) illuminance was 1330 (1160) lux in the incandescent group and 16,600 (13,000) lux in the xenon group (P < .001). Substandard illuminance was observed only in the incandescent group, in 29% to 43% of laryngoscopes; 5% of the incandescent group did not turn on at all. Maintenance of laryngoscopes was performed on a reactive rather than a preventive basis. At our facility, approximately one-third of incandescent laryngoscopes exhibited substandard light output. On the basis of these findings, our hospital has converted all of its incandescent laryngoscopes to light-emitting diode (LED) devices. Such changes, as well as the institution of a quality-control program including scheduled laryngoscope inspection and battery and bulb replacement for incandescent laryngoscopes, may reduce adverse events associated with poor-quality direct laryngoscopy.
Photoinduced currents in pristine and ion irradiated kapton-H polyimide
NASA Astrophysics Data System (ADS)
Sharma, Anu; Sridharbabu, Y.; Quamara, J. K.
2014-10-01
The photoinduced currents in pristine and ion irradiated kapton-H polyimide have been investigated for different applied electric fields at 200°C. Particularly the effect of illumination intensity on the maximum current obtained as a result of photoinduced polarization has been studied. Samples were irradiated by using PELLETRON facility, IUAC, New Delhi. The photo-carrier charge generation depends directly on intensity of illumination. The samples irradiated at higher fluence show a decrease in the peak current with intensity of illumination. The secondary radiation induced crystallinity (SRIC) is responsible for the increase in maximum photoinduced currents generated with intensity of illumination.
Interactive Dynamic Volume Illumination with Refraction and Caustics.
Magnus, Jens G; Bruckner, Stefan
2018-01-01
In recent years, significant progress has been made in developing high-quality interactive methods for realistic volume illumination. However, refraction - despite being an important aspect of light propagation in participating media - has so far only received little attention. In this paper, we present a novel approach for refractive volume illumination including caustics capable of interactive frame rates. By interleaving light and viewing ray propagation, our technique avoids memory-intensive storage of illumination information and does not require any precomputation. It is fully dynamic and all parameters such as light position and transfer function can be modified interactively without a performance penalty.
Full color natural light holographic camera.
Kim, Myung K
2013-04-22
Full-color, three-dimensional images of objects under incoherent illumination are obtained by a digital holography technique. Based on self-interference of two beam-split copies of the object's optical field with differential curvatures, the apparatus consists of a beam-splitter, a few mirrors and lenses, a piezo-actuator, and a color camera. No lasers or other special illuminations are used for recording or reconstruction. Color holographic images of daylight-illuminated outdoor scenes and a halogen lamp-illuminated toy figure are obtained. From a recorded hologram, images can be calculated, or numerically focused, at any distances for viewing.
Label-free super-resolution with coherent nonlinear structured-illumination microscopy
NASA Astrophysics Data System (ADS)
Huttunen, Mikko J.; Abbas, Aazad; Upham, Jeremy; Boyd, Robert W.
2017-08-01
Structured-illumination microscopy enables up to a two-fold lateral resolution improvement by spatially modulating the intensity profile of the illumination beam. We propose a novel way to generalize the concept of structured illumination to nonlinear widefield modalities by spatially modulating, instead of field intensities, the phase of the incident field while interferometrically measuring the complex-valued scattered field. We numerically demonstrate that for second-order and third-order processes an almost four- and six-fold increase in lateral resolution is achievable, respectively. This procedure overcomes the conventional Abbe diffraction limit and provides new possibilities for label-free super-resolution microscopy.
Photoinduced currents in pristine and ion irradiated kapton-H polyimide
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharma, Anu, E-mail: sharmaanu81@gmail.com; Sridharbabu, Y., E-mail: sharmaanu81@gmail.com; Quamara, J. K., E-mail: sharmaanu81@gmail.com
2014-10-15
The photoinduced currents in pristine and ion irradiated kapton-H polyimide have been investigated for different applied electric fields at 200°C. Particularly the effect of illumination intensity on the maximum current obtained as a result of photoinduced polarization has been studied. Samples were irradiated by using PELLETRON facility, IUAC, New Delhi. The photo-carrier charge generation depends directly on intensity of illumination. The samples irradiated at higher fluence show a decrease in the peak current with intensity of illumination. The secondary radiation induced crystallinity (SRIC) is responsible for the increase in maximum photoinduced currents generated with intensity of illumination.
Ma, Ruiqing; Kawamoto, Ken-Ichiro; Shinomori, Keizo
2016-03-01
We explored the color constancy mechanisms of color-deficient observers under red, green, blue, and yellow illuminations. The red and green illuminations were defined individually by the longer axis of the color discrimination ellipsoid measured by the Cambridge Colour Test. Four dichromats (3 protanopes and 1 deuteranope), two anomalous trichromats (2 deuteranomalous observers), and five color-normal observers were asked to complete the color constancy task by making a simultaneous paper match under asymmetrical illuminations in haploscopic view on a monitor. The von Kries adaptation model was applied to estimate the cone responses. The model fits showed that for all color-deficient observers under all illuminations, the adjustment of the S-cone response or blue-yellow chromatically opponent responses modeled with the simple assumption of cone deletion in a certain type (S-M, S-L or S-(L+M)) was consistent with the principle of the von Kries model. The degree of adaptation was similar to that of color-normal observers. The results indicate that the color constancy of color-deficient observers is mediated by the simplified blue-yellow color system with a von Kries-type adaptation effect, even in the case of brightness match, as well as by a possible cone-level adaptation to the S-cone when the illumination produces a strong S-cone stimulation, such as blue illumination.
Karimov, K S; Qazi, I; Khan, T A; Draper, P H; Khalid, F A; Mahroof-Tahir, M
2008-06-01
In this investigation properties of organic semiconductor copper phthalocyanine (CuPc) capacitive humidity and illumination sensors were studied. Organic thin film was deposited by vacuum evaporation on a glass substrate with silver surface-type electrodes to form the Ag/CuPc/Ag sensor. The capacitance of the samples was evaluated at room temperature in the relative humidity range of 35-92%. It was observed that capacitance of the Ag/CuPc/Ag sensor increases with increase in humidity. The ratio of the relative capacitance to relative humidity was about 200. It is assumed that in general the capacitive response of the sensor is associated with polarization due to absorption of water molecules and transfer of charges (electrons and holes). It was observed that under filament lamp illumination of up to 1,000 lx the capacitance of the Ag/CuPc/Ag photo capacitive detectors increased continuously by 20% as compared to dark condition. It is assumed that photo capacitive response of the sensor is associated with polarization due to transfer of photo-generated electrons and holes. An equivalent circuit of the Ag/CuPc/Ag capacitive humidity and illumination sensor was developed. Humidity and illumination dependent capacitance properties of this sensor make it attractive for use in humidity and illumination multi-meters. The sensor may be used in instruments for environmental monitoring of humidity and illumination.
NASA Astrophysics Data System (ADS)
Wang, Pengbo; Gao, Yuan; Chen, Xiao; Li, Ting
2016-03-01
Low-level light therapy (LLLT) has been clinically applied. Recently, more and more cases are reported with positive therapeutic effect by using transcranial light emitting diodes (LEDs) illumination. Here, we developed a LLLT helmet for treating brain injuries based on LED arrays. We designed the LED arrays in circle shape and assembled them in multilayered 3D printed helmet with water-cooling module. The LED arrays can be adjust to touch the head of subjects. A control circuit was developed to drive and control the illumination of the LLLT helmet. The software portion provides the control of on and off of each LED arrays, the setup of illumination parameters, and 3D distribution of LLLT light dose in human subject according to the illumination setups. This LLLT light dose distribution was computed by a Monte Carlo model for voxelized media and the Visible Chinese Human head dataset and displayed in 3D view at the background of head anatomical structure. The performance of the whole system was fully tested. One stroke patient was recruited in the preliminary LLLT experiment and the following neuropsychological testing showed obvious improvement in memory and executive functioning. This clinical case suggested the potential of this Illumination-parameter adjustable and illuminationdistribution visible LED helmet as a reliable, noninvasive, and effective tool in treating brain injuries.
Subsurface Optical Microscopy of Coarse Grain Spinels. Phase 1
2013-12-01
A 456 nm LED line bar illuminated in figure 15 and a Xenon fiber optic bar illuminator is shown for figure 16. The optical in situ or subsurface ... imaging of coarse grain spinels and AlONs is optically more complex than expected. An overhead view of the side illumination field is shown in figure 20
NASA Technical Reports Server (NTRS)
Stoker, Carol R.; Rages, Kathy
2002-01-01
We correct spectra of Yogi to remove diffuse illumination and show that the part of Yogi facing the wind is less red than other faces of the rock. Our method eliminates ambiguity in interpreting spectra obtained under Mars illumination conditions. Additional information is contained in the original extended abstract.
Transfer between Pose and Illumination Training in Face Recognition
ERIC Educational Resources Information Center
Liu, Chang Hong; Bhuiyan, Md. Al-Amin; Ward, James; Sui, Jie
2009-01-01
The relationship between pose and illumination learning in face recognition was examined in a yes-no recognition paradigm. The authors assessed whether pose training can transfer to a new illumination or vice versa. Results show that an extensive level of pose training through a face-name association task was able to generalize to a new…
Colour differences in Caucasian and Oriental women's faces illuminated by white LED sources.
Melgosa, M; Richard, N; Fernández-Maloigne, C; Xiao, K; de Clermont-Gallerande, H; Jost-Boissard, S; Okajima, K
2018-04-10
To provide an approach to facial contrast, analysing CIELAB colour differences (ΔE* ab,10 ) and its components in women's faces from two different ethnic groups, illuminated by modern white light-emitting diodes (LEDs) or traditional illuminants recommended by the International Commission on Illumination (CIE). We performed spectrophotometric measurements of spectral reflectance factors on forehead and cheek of 87 young healthy women (50 Caucasians and 37 Orientals), plus 5 commercial red lipsticks. We considered a set of 10 white LED illuminants, representative of technologies currently available on the market, plus 8 main illuminants currently recommended by the CIE, representative of conventional incandescent, daylight, and fluorescent light sources. Under each of these 18 illuminants we analysed the magnitude and components of ΔE* ab,10 between Caucasian and Oriental women (considering cheek and forehead), as well as for cheek-forehead and cheek-lipsticks in Caucasian and Oriental women. Colour-inconstancy indices for cheek, forehead, and lipsticks were computed, assuming D65 and A as reference illuminants. ΔE* ab,10 between forehead and cheek were quantitatively and qualitatively different in Orientals and Caucasians, but discrepancies with respect to average values for 18 illuminants were small (1.5% and 5.0% for Orientals and Caucasians, respectively). ΔE* ab,10 between Caucasians and Orientals were also quantitatively and qualitatively different both for forehead and cheek, and discrepancies with respect to average values were again small (1.0% and 3.9% for forehead and cheek, respectively). ΔE* ab,10 between lipsticks and cheek were at least 2 times higher than those between forehead and cheek. Regarding ΔE* ab,10 between lipsticks and cheeks, discrepancies with respect to average values were in the range 1.5% - 12.3%, although higher values of up to 54.2% were found for a white RGB LED. This white RGB LED provided the highest average colour-inconstancy indices: 17.1 and 11.5 CIELAB units, under reference illuminants D65 and A, respectively. Colour contrasts in women's faces under CIE standard illuminants for outdoor and indoor conditions may be strongly altered by using specific white LEDs. More research needs to be done on the impact of spectral power distribution of light sources with high colour rendering indices on visual colour appearance of cosmetic products. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Generation of realistic scene using illuminant estimation and mixed chromatic adaptation
NASA Astrophysics Data System (ADS)
Kim, Jae-Chul; Hong, Sang-Gi; Kim, Dong-Ho; Park, Jong-Hyun
2003-12-01
The algorithm of combining a real image with a virtual model was proposed to increase the reality of synthesized images. Currently, synthesizing a real image with a virtual model facilitated the surface reflection model and various geometric techniques. In the current methods, the characteristics of various illuminants in the real image are not sufficiently considered. In addition, despite the chromatic adaptation plays a vital role for accommodating different illuminants in the two media viewing conditions, it is not taken into account in the existing methods. Thus, it is hardly to get high-quality synthesized images. In this paper, we proposed the two-phase image synthesis algorithm. First, the surface reflectance of the maximum high-light region (MHR) was estimated using the three eigenvectors obtained from the principal component analysis (PCA) applied to the surface reflectances of 1269 Munsell samples. The combined spectral value, i.e., the product of surface reflectance and the spectral power distributions (SPDs) of an illuminant, of MHR was then estimated using the three eigenvectors obtained from PCA applied to the products of surface reflectances of Munsell 1269 samples and the SPDs of four CIE Standard Illuminants (A, C, D50, D65). By dividing the average combined spectral values of MHR by the average surface reflectances of MHR, we could estimate the illuminant of a real image. Second, the mixed chromatic adaptation (S-LMS) using an estimated and an external illuminants was applied to the virtual-model image. For evaluating the proposed algorithm, experiments with synthetic and real scenes were performed. It was shown that the proposed method was effective in synthesizing the real and the virtual scenes under various illuminants.
Herbst, Kristina; Sander, Birgit; Lund-Andersen, Henrik; Wegener, Marianne; Hannibal, Jens; Milea, Dan
2013-01-01
The intrinsically photosensitive retinal ganglion cells (ipRGCs) express the photopigment melanopsin, which is sensitive to blue light. Previous chromatic pupillometry studies have shown that the post-illumination response is considered an indicator of the melanopsin activation. The aim of this study was to investigate the ipRGC mediated pupil response in patients with a unilateral non-arteritic anterior ischemic optic neuropathy (NAION). Consensual pupil responses during and after exposure to continuous 20 s blue (470 nm) or red (660 nm) light of high intensity (300 cd/m2) were recorded in each eye for 10 patients. Comparisons were performed both intra-individually (affected versus non-affected eyes) and inter-individually (compared with healthy controls). The pupil response was calculated both during the illumination and during the post-illumination phase. The pupil responses to blue and red colors were significantly reduced in the NAION-affected eyes, compared with the fellow non-affected eyes. When comparing the affected eyes with the healthy control eyes, the post-illumination responses were not significantly different. In addition, the post-illumination pupil responses after blue light exposure were increased in the fellow non-affected patients’ eyes, compared with the healthy controls. However, significance was only reached for the late post-illumination response. In conclusion, chromatic pupillometry disclosed reduced post-illumination pupil responses in the NAION-affected eyes, compared with the non-affected fellow eyes, suggesting dysfunction of the ipRGCs. Compared with the responses of the healthy controls, the blue light post-illumination pupil responses were similar in the affected eyes and increased in the fellow non-affected eyes. This suggests a possible adaptive phenomenon, involving the ipRGCs of both eyes after unilateral NAION. PMID:23717301
Improvement of unbalanced illumination induced telecentricity within the exposure slit
NASA Astrophysics Data System (ADS)
Jang, Jonghoon; Lee, ByeongSoo; Kang, Young Seog; Chang, Chansam; Kong, Jeong-Heung; Kim, Young Ha; Bouman, Wim; de Graaf, Roelof; Weichselbaum, Stefan; Droste, Richard; de Boeij, Wim P.; van Bussel, Bart; Neefs, Patrick; Rijke, Arij
2016-03-01
Adjustment and control of the illumination pupil asymmetry is relevant for wafer alignment and overlay of lithography tools. Pupil asymmetries can cause a tilt in aerial image (Aerial Image Tilt, or AIT). This AIT, combined with a focus offset, leads to a horizontal image shift. Pupil asymmetries can be related to a shift of the entire illumination pupil (geometrical telecentricity) caused by illuminator misalign. Another type of pupil asymmetry is energetic imbalance (quantified by pupil Center of Gravity, COG). The scanner can show pupil variation across the exposure slit. In general the COG at the edge of the slit is often worse than in the center part of the slit. Recently, ASML has released the NXT:1980Di that is equipped with an enhanced illuminator to improve pupil COG variation across the slit. In this paper we explore the performance of this scanner system and show that the AIT variation across the slit is also reduced significantly.
Study on Formulation of Optimum Lighting-system for Purchasing Power at Stores
NASA Astrophysics Data System (ADS)
Fujita, Hiroki; Nakashima, Yoshio; Takamatsu, Mamoru; Oota, Masaaki; Sawa, Kazuhiro
In store lighting, difference in the look-and-feel of foods gives effects on the purchasing power of customers. This study conducted the digitalization and quantification on the effects of the variation of light-source color and illuminance used for lighting foods on image recognition on foods. As a result, it was clarified that when meat was illuminated with the light source of “pink” or “faint pink,” image evaluation on foods became higher. In addition, when illuminance increase was applied to these two light-source colors, image evaluation on “faint pink” became further higher. The reason is supposed to be that the redness of meat increased, which may have enhanced fresher impression. From this study, it has been clarified that the light-source color and illuminance optimum for each food are variant. The results show that lighting foods with the optimum light-source color and illuminance can make foods look better.
Active illuminated space object imaging and tracking simulation
NASA Astrophysics Data System (ADS)
Yue, Yufang; Xie, Xiaogang; Luo, Wen; Zhang, Feizhou; An, Jianzhu
2016-10-01
Optical earth imaging simulation of a space target in orbit and it's extraction in laser illumination condition were discussed. Based on the orbit and corresponding attitude of a satellite, its 3D imaging rendering was built. General simulation platform was researched, which was adaptive to variable 3D satellite models and relative position relationships between satellite and earth detector system. Unified parallel projection technology was proposed in this paper. Furthermore, we denoted that random optical distribution in laser-illuminated condition was a challenge for object discrimination. Great randomicity of laser active illuminating speckles was the primary factor. The conjunction effects of multi-frame accumulation process and some tracking methods such as Meanshift tracking, contour poid, and filter deconvolution were simulated. Comparison of results illustrates that the union of multi-frame accumulation and contour poid was recommendable for laser active illuminated images, which had capacities of high tracking precise and stability for multiple object attitudes.
Integral freeform illumination lens design of LED based pico-projector.
Zhao, Shuang; Wang, Kai; Chen, Fei; Qin, Zong; Liu, Sheng
2013-05-01
In this paper, an illumination lens design for a LED-based pico-projector is presented. Different from the traditional illumination systems composed by lens group, the integral illumination lens consists of a total internal reflector (TIR) and a freeform surface. TIR acts as collimation lens and its top surface formed by a freeform surface reshapes the nonuniform circular light pattern generated by TIR to be rectangular and uniform. Diameter and height of the lens are 16 and 10 mm, respectively. An optimization method to deal with the problem of extended light source is also presented in detail in this paper. According to the simulation results of the final optimized lens, 77% (neglecting the effect of polarization) of the power of light source is collected on liquid crystal on silicon panel with a 16∶9 ratio and illumination uniformity achieves 92%.
Critical illumination condenser for x-ray lithography
Cohen, S.J.; Seppala, L.G.
1998-04-07
A critical illumination condenser system is disclosed, particularly adapted for use in extreme ultraviolet (EUV) projection lithography based on a ring field imaging system and a laser produced plasma source. The system uses three spherical mirrors and is capable of illuminating the extent of the mask plane by scanning either the primary mirror or the laser plasma source. The angles of radiation incident upon each mirror of the critical illumination condenser vary by less than eight (8) degrees. For example, the imaging system in which the critical illumination condenser is utilized has a 200 {micro}m source and requires a magnification of 26. The three spherical mirror system constitutes a two mirror inverse Cassegrain, or Schwarzschild configuration, with a 25% area obstruction (50% linear obstruction). The third mirror provides the final pupil and image relay. The mirrors include a multilayer reflective coating which is reflective over a narrow bandwidth. 6 figs.
RESPIRATION AND INTENSITY DEPENDENCE OF PHOTOSYNTHESIS IN CHLORELLA
Brackett, Frederick S.; Olson, Rodney A.; Crickard, Robert G.
1953-01-01
1. Respiration changes as a result of illumination. 2. In the absence of glucose or other supply of substrate, respiration decays in the dark showing at least two types—a fast decay in a few minutes and a slow decay lasting hours. 3. Respiratory response to illumination is delayed. 4. Intermittent illumination (in the absence of glucose, etc.) produces a periodic variation in respiration with a delay or phase lag. 5. Periodic variation of respiration may produce a higher average value in the dark than in the light due to the lag and depending upon the period of intermittent illumination. 6. Based upon average respiration values our data confirm the Kok effect. 7. Interpolated values of respiration, however, result in photosynthetic rates which are linearly dependent upon intensity of illumination. 8. Thus the quantum efficiency is found to be independent of intensity, over the wide range of intensities investigated. PMID:13035068
Kiyokawa, Masatoshi; Sakuma, Toshiro; Hatano, Noriko; Mizota, Atsushi; Tanaka, Minoru
2009-06-01
The purpose of this article is to report the characteristics and advantages of using a newly designed quartz contact lens with slit illumination from an operating microscope for intraocular surgery. The new contact lens is made of quartz. The lens is convex-concave and is used in combination with slit illumination from an operating microscope. The optical properties of quartz make this lens less reflective with greater transmittance. The combination of a quartz contact lens with slit illumination provided a brighter and wider field of view than conventional lenses. This system enabled us to perform bimanual vitrectomy and scleral buckling surgery without indirect ophthalmoscope. Small intraocular structures in the posterior pole or in the periphery were detected more easily. In conclusion, the newly designed quartz lens with slit beam illumination from an operating microscope provided a bright, clear and wide surgical field, and allowed intraocular surgery to be performed more easily.
Supercontinuum as a light source for miniaturized endoscopes.
Lu, M K; Lin, H Y; Hsieh, C C; Kao, F J
2016-09-01
In this work, we have successfully implemented supercontinuum based illumination through single fiber coupling. The integration of a single fiber illumination with a miniature CMOS sensor forms a very slim and powerful camera module for endoscopic imaging. A set of tests and in vivo animal experiments are conducted accordingly to characterize the corresponding illuminance, spectral profile, intensity distribution, and image quality. The key illumination parameters of the supercontinuum, including color rendering index (CRI: 72%~97%) and correlated color temperature (CCT: 3,100K~5,200K), are modified with external filters and compared with those from a LED light source (CRI~76% & CCT~6,500K). The very high spatial coherence of the supercontinuum allows high luminosity conduction through a single multimode fiber (core size~400μm), whose distal end tip is attached with a diffussion tip to broaden the solid angle of illumination (from less than 10° to more than 80°).
Low-Light-Level InGaAs focal plane arrays with and without illumination
NASA Astrophysics Data System (ADS)
Macdougal, Michael; Geske, Jon; Wang, Chad; Follman, David
2010-04-01
Short wavelength IR imaging using InGaAs-based FPAs is shown. Aerius demonstrates low dark current in InGaAs detector arrays with 15 μm pixel pitch. The same material is mated with a 640x 512 CTIA-based readout integrated circuit. The resulting FPA is capable of imaging photon fluxes with wavelengths between 1 and 1.6 microns at low light levels. The mean dark current density on the FPAs is extremely low at 0.64 nA/cm2 at 10°C. Noise due to the readout can be reduced from 95 to 57 electrons by using off-chip correlated double sampling (CDS). In addition, Aerius has developed laser arrays that provide flat illumination in scenes that are normally light-starved. The illuminators have 40% wall-plug efficiency and provide speckle-free illumination, provide artifact-free imagery versus conventional laser illuminators.
Color constancy by characterization of illumination chromaticity
NASA Astrophysics Data System (ADS)
Nikkanen, Jarno T.
2011-05-01
Computational color constancy algorithms play a key role in achieving desired color reproduction in digital cameras. Failure to estimate illumination chromaticity correctly will result in invalid overall colour cast in the image that will be easily detected by human observers. A new algorithm is presented for computational color constancy. Low computational complexity and low memory requirement make the algorithm suitable for resource-limited camera devices, such as consumer digital cameras and camera phones. Operation of the algorithm relies on characterization of the range of possible illumination chromaticities in terms of camera sensor response. The fact that only illumination chromaticity is characterized instead of the full color gamut, for example, increases robustness against variations in sensor characteristics and against failure of diagonal model of illumination change. Multiple databases are used in order to demonstrate the good performance of the algorithm in comparison to the state-of-the-art color constancy algorithms.
Low energy sign illumination system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Minogue, R.W.
A low energy sign contruction is illustrated for illumination of signs of the type having translucent illuminated faces. An opaque sign border is bridged by a reflector extending generally parallel to the illuminated face and having a truncated sawtooth profile. For single sided signs, one set of sawtooth points is truncated; for dual sided signs, both set of sawtooth points are truncated. Bayonet mounted lighting sockets are mounted at apertures in the respective truncations and utilize the metallic reflective surface as one side of a low voltage (10.5-volt) ac circuit. The reflector forms a cooled heat sink mounting the bulbsmore » as well as a supporting matrix. The lamps, as mounted to this supporting matrix, are typically spaced at distances which do not exceed twice the distance of the lamp filament to the translucent face. By the expedient of using 14-V lamps, prolonged lamp life with low energy illumination results.« less
Critical illumination condenser for x-ray lithography
Cohen, Simon J.; Seppala, Lynn G.
1998-01-01
A critical illumination condenser system, particularly adapted for use in extreme ultraviolet (EUV) projection lithography based on a ring field imaging system and a laser produced plasma source. The system uses three spherical mirrors and is capable of illuminating the extent of the mask plane by scanning either the primary mirror or the laser plasma source. The angles of radiation incident upon each mirror of the critical illumination condenser vary by less than eight (8) degrees. For example, the imaging system in which the critical illumination condenser is utilized has a 200 .mu.m source and requires a magnification of 26.times.. The three spherical mirror system constitutes a two mirror inverse Cassegrain, or Schwarzschild configuration, with a 25% area obstruction (50% linear obstruction). The third mirror provides the final pupil and image relay. The mirrors include a multilayer reflective coating which is reflective over a narrow bandwidth.
Pulsed laser linescanner for a backscatter absorption gas imaging system
Kulp, Thomas J.; Reichardt, Thomas A.; Schmitt, Randal L.; Bambha, Ray P.
2004-02-10
An active (laser-illuminated) imaging system is described that is suitable for use in backscatter absorption gas imaging (BAGI). A BAGI imager operates by imaging a scene as it is illuminated with radiation that is absorbed by the gas to be detected. Gases become "visible" in the image when they attenuate the illumination creating a shadow in the image. This disclosure describes a BAGI imager that operates in a linescanned manner using a high repetition rate pulsed laser as its illumination source. The format of this system allows differential imaging, in which the scene is illuminated with light at least 2 wavelengths--one or more absorbed by the gas and one or more not absorbed. The system is designed to accomplish imaging in a manner that is insensitive to motion of the camera, so that it can be held in the hand of an operator or operated from a moving vehicle.
On analyzing colour constancy approach for improving SURF detector performance
NASA Astrophysics Data System (ADS)
Zulkiey, Mohd Asyraf; Zaki, Wan Mimi Diyana Wan; Hussain, Aini; Mustafa, Mohd. Marzuki
2012-04-01
Robust key point detector plays a crucial role in obtaining a good tracking feature. The main challenge in outdoor tracking is the illumination change due to various reasons such as weather fluctuation and occlusion. This paper approaches the illumination change problem by transforming the input image through colour constancy algorithm before applying the SURF detector. Masked grey world approach is chosen because of its ability to perform well under local as well as global illumination change. Every image is transformed to imitate the canonical illuminant and Gaussian distribution is used to model the global change. The simulation results show that the average number of detected key points have increased by 69.92%. Moreover, the average of improved performance cases far out weight the degradation case where the former is improved by 215.23%. The approach is suitable for tracking implementation where sudden illumination occurs frequently and robust key point detection is needed.
White constancy method for mobile displays
NASA Astrophysics Data System (ADS)
Yum, Ji Young; Park, Hyun Hee; Jang, Seul Ki; Lee, Jae Hyang; Kim, Jong Ho; Yi, Ji Young; Lee, Min Woo
2014-03-01
In these days, consumer's needs for image quality of mobile devices are increasing as smartphone is widely used. For example, colors may be perceived differently when displayed contents under different illuminants. Displayed white in incandescent lamp is perceived as bluish, while same content in LED light is perceived as yellowish. When changed in perceived white under illuminant environment, image quality would be degraded. Objective of the proposed white constancy method is restricted to maintain consistent output colors regardless of the illuminants utilized. Human visual experiments are performed to analyze viewers'perceptual constancy. Participants are asked to choose the displayed white in a variety of illuminants. Relationship between the illuminants and the selected colors with white are modeled by mapping function based on the results of human visual experiments. White constancy values for image control are determined on the predesigned functions. Experimental results indicate that propsed method yields better image quality by keeping the display white.
Laser Illumination Modality of Photoacoustic Imaging Technique for Prostate Cancer
NASA Astrophysics Data System (ADS)
Peng, Dong-qing; Peng, Yuan-yuan; Guo, Jian; Li, Hui
2016-02-01
Photoacoustic imaging (PAI) has recently emerged as a promising imaging technique for prostate cancer. But there was still a lot of challenge in the PAI for prostate cancer detection, such as laser illumination modality. Knowledge of absorbed light distribution in prostate tissue was essential since the distribution characteristic of absorbed light energy would influence the imaging depth and range of PAI. In order to make a comparison of different laser illumination modality of photoacoustic imaging technique for prostate cancer, optical model of human prostate was established and combined with Monte Carlo simulation method to calculate the light absorption distribution in the prostate tissue. Characteristic of light absorption distribution of transurethral and trans-rectal illumination case, and of tumor at different location was compared with each other.The relevant conclusions would be significant for optimizing the light illumination in a PAI system for prostate cancer detection.
Development of electroluminescence based pressure-sensitive paint system.
Iijima, Yoshimi; Sakaue, Hirotaka
2011-01-01
We introduce a pressure-sensitive paint (PSP) measurement system based on an electroluminescence (EL) as a surface illumination. This consists of an inorganic EL as the illumination, a short-pass filter, and a platinum-porphyrin based PSP. The short-pass filter, which passes below 500 nm, was used to separate an overlay of the EL illumination and the PSP emission. The EL shows an opposite temperature dependency to that of the PSP. It gives a uniform illumination compared to that of a point illumination source such as a xenon lamp. Under atmospheric conditions, the resultant EL-PSP system reduces the temperature dependency by 54% compared to that of a conventional PSP system. An application of the EL-PSP system to a sonic jet impingement shows that the system demonstrated its reduction of the temperature dependency by 75% in a pressure measurement and reduces an image misalignment error.
Illumination from space with orbiting solar-reflector spacecraft
NASA Technical Reports Server (NTRS)
Canady, J. E., Jr.; Allen, J. L., Jr.
1982-01-01
The feasibility of using orbiting mirrors to reflect sunlight to Earth for several illumination applications is studied. A constellation of sixteen 1 km solar reflector spacecraft in geosynchronous orbit can illuminate a region 333 km in diameter to 8 lux, which is brighter than most existing expressway lighting systems. This constellation can serve one region all night long or can provide illumination during mornings and evenings to five regions across the United States. Preliminary cost estimates indicate such an endeavor is economically feasible. The studies also explain how two solar reflectors can illuminate the in-orbit nighttime operations of Space Shuttle. An unfurlable, 1 km diameter solar reflector spacecraft design concept was derived. This spacecraft can be packaged in the Space, Shuttle, transported to low Earth orbit, unfurled, and solar sailed to operational orbits up to geosynchronous. The necessary technical studies and improvements in technology are described, and potential environmental concerns are discussed.
ERIC Educational Resources Information Center
van Rensburg, Estelle
2008-01-01
This article outlines an illuminative evaluation study of the work-based module in a vocational qualification in Animal Health offered for the paraveterinary industry by a distance education institution in South Africa. In illuminative evaluation, a programme is studied by qualitative methods to gain an in-depth understanding of its…
ERIC Educational Resources Information Center
Illuminating Engineering Research Inst., New York, NY.
Several of the more familiar Illuminating Engineering Research Institute projects which have been chronicled progressively during the past several years are discussed in this report. Those elaborated on are--(1) visual performance and illumination, (2) roadway visual tasks, (3) color preference studies, (4) glare from large sources, (5) discomfort…
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Uniform test method for the measurement of energy consumption of illuminated exit signs. 431.204 Section 431.204 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION... Procedures § 431.204 Uniform test method for the measurement of energy consumption of illuminated exit signs...
A method of solving tilt illumination for multiple distance phase retrieval
NASA Astrophysics Data System (ADS)
Guo, Cheng; Li, Qiang; Tan, Jiubin; Liu, Shutian; Liu, Zhengjun
2018-07-01
Multiple distance phase retrieval is a technique of using a series of intensity patterns to reconstruct a complex-valued image of object. However, tilt illumination originating from the off-axis displacement of incident light significantly impairs its imaging quality. To eliminate this affection, we use cross-correlation calibration to estimate oblique angle of incident light and a Fourier-based strategy to correct tilted illumination effect. Compared to other methods, binary and biological object are both stably reconstructed in simulation and experiment. This work provides a simple but beneficial method to solve the problem of tilt illumination for lens-free multi-distance system.
Zhang, Haiyan; Vasanthan, Thava; Wettasinghe, Mahinda
2004-12-29
The effect of germination and growth under illuminated and dark environments on canola seed reserves was investigated. Depletion of proteins and lipids in whole seedlings and their top (leaf/cotyledons) and bottom parts (stem/roots/seed coat) was independent of light, whereas the protein solubility increased at a faster rate under an illuminated environment than in the dark. A rapid increase in free fatty acids but a net decrease of dry matter content in seedlings grown in the dark environment was observed. The dry matter content of seedlings grown in the illuminated environment increased due to photosynthetic biomass accumulation.
Sun, Wen-Shing; Tien, Chuen-Lin; Tsuei, Chih-Hsuan; Pan, Jui-Wen
2014-10-10
We simulate and compare the illuminance, uniformity, and efficiency of metal-halide lamps, white LED light sources, and hybrid light box designs combining sunlight and white LED lighting used for indoor basketball court illumination. According to the optical simulation results and our examination of real situations, we find that hybrid light box designs combining sunlight and white LEDs do perform better than either metal-halide lamps or white LED lights. An evaluation of the sunlight concentrator system used in our inverted solar cell shows that the energy consumption of stadium lighting can be reduced significantly.
Mutual Comparative Filtering for Change Detection in Videos with Unstable Illumination Conditions
NASA Astrophysics Data System (ADS)
Sidyakin, Sergey V.; Vishnyakov, Boris V.; Vizilter, Yuri V.; Roslov, Nikolay I.
2016-06-01
In this paper we propose a new approach for change detection and moving objects detection in videos with unstable, abrupt illumination changes. This approach is based on mutual comparative filters and background normalization. We give the definitions of mutual comparative filters and outline their strong advantage for change detection purposes. Presented approach allows us to deal with changing illumination conditions in a simple and efficient way and does not have drawbacks, which exist in models that assume different color transformation laws. The proposed procedure can be used to improve a number of background modelling methods, which are not specifically designed to work under illumination changes.
Three-dimensional wide-field pump-probe structured illumination microscopy
Kim, Yang-Hyo; So, Peter T.C.
2017-01-01
We propose a new structured illumination scheme for achieving depth resolved wide-field pump-probe microscopy with sub-diffraction limit resolution. By acquiring coherent pump-probe images using a set of 3D structured light illumination patterns, a 3D super-resolution pump-probe image can be reconstructed. We derive the theoretical framework to describe the coherent image formation and reconstruction scheme for this structured illumination pump-probe imaging system and carry out numerical simulations to investigate its imaging performance. The results demonstrate a lateral resolution improvement by a factor of three and providing 0.5 µm level axial optical sectioning. PMID:28380860
NASA Astrophysics Data System (ADS)
Hamadeh, H.; Naddaf, M.; Jazmati, A.
2008-12-01
Porous silicon (PS) has been prepared by anodic etching of boron doped silicon under the influence of monochromatic light illumination. The optical properties of the PS samples have been investigated using temperature dependent photoluminescence (PL) spectroscopy. An overall enhancement of the infrared luminescence yield is caused by the light illumination. In the visible spectral range, changes at the low energy side of the broad PL band were observed. In the near infrared spectral range, a new PL band at 850 nm, which is strongly correlated with light illumination, was detected. The new PL band disappears once blue light is used, whereas an increase in its intensity is observed, when the etching is performed under the illumination of light with wavelengths close to the band gap. By increasing the temperature, the 850 nm transition band grows at the expense of the main near infrared transition at 1100 nm. The recombination characteristics of this PL band are indicative of its extrinsic nature. The macroscopic morphology shows strong dependence on the wavelength of the illumination light. Photoassisted preparation could provide a tool for the control of the optical and structural properties of PS.
NASA Astrophysics Data System (ADS)
Li, Shuo; Wang, Hui; Wang, Liyong; Yu, Xiangzhou; Yang, Le
2018-01-01
The uneven illumination phenomenon reduces the quality of remote sensing image and causes interference in the subsequent processing and applications. A variational method based on Retinex with double-norm hybrid constraints for uneven illumination correction is proposed. The L1 norm and the L2 norm are adopted to constrain the textures and details of reflectance image and the smoothness of the illumination image, respectively. The problem of separating the illumination image from the reflectance image is transformed into the optimal solution of the variational model. In order to accelerate the solution, the split Bregman method is used to decompose the variational model into three subproblems, which are calculated by alternate iteration. Two groups of experiments are implemented on two synthetic images and three real remote sensing images. Compared with the variational Retinex method with single-norm constraint and the Mask method, the proposed method performs better in both visual evaluation and quantitative measurements. The proposed method can effectively eliminate the uneven illumination while maintaining the textures and details of the remote sensing image. Moreover, the proposed method using split Bregman method is more than 10 times faster than the method with the steepest descent method.
Shaping plasmon beams via the controlled illumination of finite-size plasmonic crystals
Bouillard, J.-S.; Segovia, P.; Dickson, W.; Wurtz, G. A.; Zayats, A. V.
2014-01-01
Plasmonic crystals provide many passive and active optical functionalities, including enhanced sensing, optical nonlinearities, light extraction from LEDs and coupling to and from subwavelength waveguides. Here we study, both experimentally and numerically, the coherent control of SPP beam excitation in finite size plasmonic crystals under focussed illumination. The correct combination of the illuminating spot size, its position relative to the plasmonic crystal, wavelength and polarisation enables the efficient shaping and directionality of SPP beam launching. We show that under strongly focussed illumination, the illuminated part of the crystal acts as an antenna, launching surface plasmon waves which are subsequently filtered by the surrounding periodic lattice. Changing the illumination conditions provides rich opportunities to engineer the SPP emission pattern. This offers an alternative technique to actively modulate and control plasmonic signals, either via micro- and nano-electromechanical switches or with electro- and all-optical beam steering which have direct implications for the development of new integrated nanophotonic devices, such as plasmonic couplers and switches and on-chip signal demultiplexing. This approach can be generalised to all kinds of surface waves, either for the coupling and discrimination of light in planar dielectric waveguides or the generation and control of non-diffractive SPP beams. PMID:25429786
Depth Structure from Asymmetric Shading Supports Face Discrimination
Chen, Chien-Chung; Chen, Chin-Mei; Tyler, Christopher W.
2013-01-01
To examine the effect of illumination direction on the ability of observers to discriminate between faces, we manipulated the direction of illumination on scanned 3D face models. In order to dissociate the surface reflectance and illumination components of front-view face images, we introduce a symmetry algorithm that can separate the symmetric and asymmetric components of the face in both low and high spatial frequency bands. Based on this approach, hybrid faces stimuli were constructed with different combinations of symmetric and asymmetric spatial content. Discrimination results with these images showed that asymmetric illumination information biased face perception toward the structure of the shading component, while the symmetric illumination information had little, if any, effect. Measures of perceived depth showed that this property increased systematically with the asymmetric but not the symmetric low spatial frequency component. Together, these results suggest that (1) the asymmetric 3D shading information dramatically affects both the perceived facial information and the perceived depth of the facial structure; and (2) these effects both increase as the illumination direction is shifted to the side. Thus, our results support the hypothesis that face processing has a strong 3D component. PMID:23457484
Color rendering indices in global illumination methods
NASA Astrophysics Data System (ADS)
Geisler-Moroder, David; Dür, Arne
2009-02-01
Human perception of material colors depends heavily on the nature of the light sources used for illumination. One and the same object can cause highly different color impressions when lit by a vapor lamp or by daylight, respectively. Based on state-of-the-art colorimetric methods we present a modern approach for calculating color rendering indices (CRI), which were defined by the International Commission on Illumination (CIE) to characterize color reproduction properties of illuminants. We update the standard CIE method in three main points: firstly, we use the CIELAB color space, secondly, we apply a Bradford transformation for chromatic adaptation, and finally, we evaluate color differences using the CIEDE2000 total color difference formula. Moreover, within a real-world scene, light incident on a measurement surface is composed of a direct and an indirect part. Neumann and Schanda1 have shown for the cube model that interreflections can influence the CRI of an illuminant. We analyze how color rendering indices vary in a real-world scene with mixed direct and indirect illumination and recommend the usage of a spectral rendering engine instead of an RGB based renderer for reasons of accuracy of CRI calculations.
PET and NIR Optical Imaging Using Self-Illuminating 64Cu-Doped Chelator-Free Gold Nanoclusters
Hu, Hao; Huang, Peng; Weiss, Orit Jacobson; Yan, Xuefeng; Yue, Xuyi; Zhang, Molly Gu; Tang, Yuxia; Nie, Liming; Ma, Ying; Niu, Gang; Wu, Kaichun; Chen, Xiaoyuan
2014-01-01
Self-illuminating fluorescence imaging without autofluorescence background interference has recently aroused more research interests in molecular imaging. Currently, only a few self-illuminating probes were developed, based mainly on toxic quantum dots such as CdSe, CdTe. Herein, we report a novel design of nontoxic self-illuminating gold nanocluster (64Cu-doped AuNCs) for dual-modality positron emission tomography (PET) and near-infrared (NIR) fluorescence imaging based on Cerenkov resonance energy transfer (CRET). PET radionuclide 64Cu was introduced by a chelator-free doping method, which played dual roles as the energy donor and the PET imaging source. Meanwhile, AuNCs acted as the energy acceptor for NIR fluorescence imaging. 64Cu-doped AuNCs exhibited efficient CRET-NIR and PET imaging both in vitro and in vivo. In a U87MG glioblastoma xenograft model, 64Cu-doped AuNCs showed high tumor uptake (14.9%ID/g at 18 h) and produced satisfactory tumor self-illuminating NIR images in the absence of external excitation. This self-illuminating nanocluster with non-toxicity and good biocompatibility can be employed as a novel imaging contrast agent for biomedical applications, especially for molecular imaging. PMID:25224367
PET and NIR optical imaging using self-illuminating (64)Cu-doped chelator-free gold nanoclusters.
Hu, Hao; Huang, Peng; Weiss, Orit Jacobson; Yan, Xuefeng; Yue, Xuyi; Zhang, Molly Gu; Tang, Yuxia; Nie, Liming; Ma, Ying; Niu, Gang; Wu, Kaichun; Chen, Xiaoyuan
2014-12-01
Self-illuminating fluorescence imaging without autofluorescence background interference has recently aroused more research interests in molecular imaging. Currently, only a few self-illuminating probes were developed, based mainly on toxic quantum dots such as CdSe, CdTe. Herein, we report a novel design of nontoxic self-illuminating gold nanocluster ((64)Cu-doped AuNCs) for dual-modality positron emission tomography (PET) and near-infrared (NIR) fluorescence imaging based on Cerenkov resonance energy transfer (CRET). PET radionuclide (64)Cu was introduced by a chelator-free doping method, which played dual roles as the energy donor and the PET imaging source. Meanwhile, AuNCs acted as the energy acceptor for NIR fluorescence imaging. (64)Cu-doped AuNCs exhibited efficient CRET-NIR and PET imaging both in vitro and in vivo. In a U87MG glioblastoma xenograft model, (64)Cu-doped AuNCs showed high tumor uptake (14.9 %ID/g at 18 h) and produced satisfactory tumor self-illuminating NIR images in the absence of external excitation. This self-illuminating nanocluster with non-toxicity and good biocompatibility can be employed as a novel imaging contrast agent for biomedical applications, especially for molecular imaging. Published by Elsevier Ltd.
Complementary aspects of spatial resolution and signal-to-noise ratio in computational imaging
NASA Astrophysics Data System (ADS)
Gureyev, T. E.; Paganin, D. M.; Kozlov, A.; Nesterets, Ya. I.; Quiney, H. M.
2018-05-01
A generic computational imaging setup is considered which assumes sequential illumination of a semitransparent object by an arbitrary set of structured coherent illumination patterns. For each incident illumination pattern, all transmitted light is collected by a photon-counting bucket (single-pixel) detector. The transmission coefficients measured in this way are then used to reconstruct the spatial distribution of the object's projected transmission. It is demonstrated that the square of the spatial resolution of such a setup is usually equal to the ratio of the image area to the number of linearly independent illumination patterns. If the noise in the measured transmission coefficients is dominated by photon shot noise, then the ratio of the square of the mean signal to the noise variance is proportional to the ratio of the mean number of registered photons to the number of illumination patterns. The signal-to-noise ratio in a reconstructed transmission distribution is always lower if the illumination patterns are nonorthogonal, because of spatial correlations in the measured data. Examples of imaging methods relevant to the presented analysis include conventional imaging with a pixelated detector, computational ghost imaging, compressive sensing, super-resolution imaging, and computed tomography.
Spectrally enhanced image resolution of tooth enamel surfaces
NASA Astrophysics Data System (ADS)
Zhang, Liang; Nelson, Leonard Y.; Berg, Joel H.; Seibel, Eric J.
2012-01-01
Short-wavelength 405 nm laser illumination of surface dental enamel using an ultrathin scanning fiber endoscope (SFE) produced enhanced detail of dental topography. The surfaces of human extracted teeth and artificial erosions were imaged with 405 nm, 444 nm, 532 nm, or 635 nm illumination lasers. The obtained images were then processed offline to compensate for any differences in the illumination beam diameters between the different lasers. Scattering and absorption coefficients for a Monte Carlo model of light propagation in dental enamel for 405 nm were scaled from published data at 532 nm and 633 nm. The value of the scattering coefficient used in the model was scaled from the coefficients at 532 nm and 633 nm by the inverse third power of wavelength. Simulations showed that the penetration depth of short-wavelength illumination is localized close to the enamel surface, while long-wavelength illumination travels much further and is backscattered from greater depths. Therefore, images obtained using short wavelength laser are not contaminated by the superposition of light reflected from enamel tissue at greater depths. Hence, the SFE with short-wavelength illumination may make it possible to visualize surface manifestations of phenomena such as demineralization, thus better aiding the clinician in the detection of early caries.
Laser exposure incidents: pilot ocular health and aviation safety issues.
Nakagawara, Van B; Wood, Kathryn J; Montgomery, Ron W
2008-09-01
A database of aviation reports involving laser illumination of flight crewmembers has been established and maintained at the Civil Aerospace Medical Institute. A review of recent laser illumination reports was initiated to investigate the significance of these events. Reports that involved laser exposures of civilian aircraft in the United States were analyzed for the 13-month period (January 1, 2004, through January 31, 2005). There were 90 reported instances of laser illumination during the study period. A total of 53 reports involved laser exposure of commercial aircraft. Lasers illuminated the cockpit in 41 (46%) of the incidents. Of those, 13 (32%) incidents resulted in a visual impairment or distraction to a pilot, including 1 incident that reportedly resulted in an ocular injury. Nearly 96% of these reports occurred in the last 3 months of the study period. There were no aviation accidents in which laser light illumination was found to be a contributing factor. Operational problems have resulted from laser illumination incidents in the national airspace system. Eye care practitioners, to provide effective consultations to their pilot patients, should be familiar with the problems that can occur with laser exposure.
Changing lamp type and position to improve lighting quality
NASA Astrophysics Data System (ADS)
Anizar; Syahputri, K.; Sari, RM; Rizkya, I.; Hardianti, DA
2018-03-01
This study investigates the lighting quality on the production floor in a cigarette paper industry by measuring illumination level and luminance. Cigarette paper inspection is performed manually by operators, and the criteria of defects are the cigarette paper has a hole, is rough and dirty. Operators complain that the room is pretty dark, which makes them unable to see clearly the cigarette paper defect. The government of Indonesia Health Ministerial Decree No 1405 The Year 2002 states that illumination level for continuous manual labor is 200 lux. Illumination level is measured for four days at 08.00, 10.00, 12.30, and 14.00 o’clock with 4 in 1 environmental meter. From the measurement result, it is found that using 7 LED lamps of 60 Watts can produce average illumination level of 70 lux. Low illuminance is caused by illumination level that does not meet the need 0f 569.759 lumen. Alternatives that can be used to increase lumen number are changing lamp type and position. One of the possibilities is using 24 LED of 138 Watts set 5.7 meters apart from one another can meet this demand. Another is using 5 LED of 150 Watts installed above the field of work.
Effects of illumination on image reconstruction via Fourier ptychography
NASA Astrophysics Data System (ADS)
Cao, Xinrui; Sinzinger, Stefan
2017-12-01
The Fourier ptychographic microscopy (FPM) technique provides high-resolution images by combining a traditional imaging system, e.g. a microscope or a 4f-imaging system, with a multiplexing illumination system, e.g. an LED array and numerical image processing for enhanced image reconstruction. In order to numerically combine images that are captured under varying illumination angles, an iterative phase-retrieval algorithm is often applied. However, in practice, the performance of the FPM algorithm degrades due to the imperfections of the optical system, the image noise caused by the camera, etc. To eliminate the influence of the aberrations of the imaging system, an embedded pupil function recovery (EPRY)-FPM algorithm has been proposed [Opt. Express 22, 4960-4972 (2014)]. In this paper, we study how the performance of FPM and EPRY-FPM algorithms are affected by imperfections of the illumination system using both numerical simulations and experiments. The investigated imperfections include varying and non-uniform intensities, and wavefront aberrations. Our study shows that the aberrations of the illumination system significantly affect the performance of both FPM and EPRY-FPM algorithms. Hence, in practice, aberrations in the illumination system gain significant influence on the resulting image quality.
Violet LED light enhances the recruitment of a thrip predator in open fields.
Ogino, Takumi; Uehara, Takuya; Muraji, Masahiko; Yamaguchi, Terumi; Ichihashi, Takahisa; Suzuki, Takahiro; Kainoh, Yooichi; Shimoda, Masami
2016-09-08
The predatory bug Orius sauteri is an indigenous natural enemy of thrips and whiteflies in Asian countries. To put these bugs to practical use in pest management, methods to attract and retain the bugs in agricultural fields are needed. We previously showed that violet light (405 nm) attracts O. sauteri selectively. Many thrips and whiteflies are attracted to UV or green light. In this study, we examined the effect of violet-LED illumination on O. sauteri in pesticide-free eggplant (Solanum melongena L.) cultivation. In three cultivation trials, the density of O. sauteri on eggplant leaves was consistently higher in the illuminated plots; at least twice that of the non-illuminated plots. Simultaneously, the density of thrips declined markedly to less than half that of the non-illuminated plots. We identified three positive effects of violet light including an "immediate-effect" on predator attraction, a "persistent-effect" on predator reproduction, and a "secondary-effect" on the food web structure. Our results showed that illumination with violet light provides a powerful tool for integrated pest management. This is the first report on the use of illumination to manipulate the behavior of natural enemies.
Violet LED light enhances the recruitment of a thrip predator in open fields
Ogino, Takumi; Uehara, Takuya; Muraji, Masahiko; Yamaguchi, Terumi; Ichihashi, Takahisa; Suzuki, Takahiro; Kainoh, Yooichi; Shimoda, Masami
2016-01-01
The predatory bug Orius sauteri is an indigenous natural enemy of thrips and whiteflies in Asian countries. To put these bugs to practical use in pest management, methods to attract and retain the bugs in agricultural fields are needed. We previously showed that violet light (405 nm) attracts O. sauteri selectively. Many thrips and whiteflies are attracted to UV or green light. In this study, we examined the effect of violet-LED illumination on O. sauteri in pesticide-free eggplant (Solanum melongena L.) cultivation. In three cultivation trials, the density of O. sauteri on eggplant leaves was consistently higher in the illuminated plots; at least twice that of the non-illuminated plots. Simultaneously, the density of thrips declined markedly to less than half that of the non-illuminated plots. We identified three positive effects of violet light including an “immediate-effect” on predator attraction, a “persistent-effect” on predator reproduction, and a “secondary-effect” on the food web structure. Our results showed that illumination with violet light provides a powerful tool for integrated pest management. This is the first report on the use of illumination to manipulate the behavior of natural enemies. PMID:27604315
Wide-area SWIR arrays and active illuminators
NASA Astrophysics Data System (ADS)
MacDougal, Michael; Hood, Andrew; Geske, Jon; Wang, Chad; Renner, Daniel; Follman, David; Heu, Paula
2012-01-01
We describe the factors that go into the component choices for a short wavelength (SWIR) imager, which include the SWIR sensor, the lens, and the illuminator. We have shown the factors for reducing dark current, and shown that we can achieve well below 1.5 nA/cm2 for 15 μm devices at 7°C. We have mated our InGaAs detector arrays to 640x512 readout integrated integrated circuits (ROICs) to make focal plane arrays (FPAs). In addition, we have fabricated high definition 1920x1080 FPAs for wide field of view imaging. The resulting FPAs are capable of imaging photon fluxes with wavelengths between 1 and 1.6 microns at low light levels. The dark current associated with these FPAs is extremely low, exhibiting a mean dark current density of 0.26 nA/cm2 at 0°C. FLIR has also developed a high definition, 1920x1080, 15 um pitch SWIR sensor. In addition, FLIR has developed laser arrays that provide flat illumination in scenes that are normally light-starved. The illuminators have 40% wall-plug efficiency and provide low-speckle illumination, provide artifact-free imagery versus conventional laser illuminators.
NASA Astrophysics Data System (ADS)
Macdougal, Michael; Geske, Jon; Wang, Chad; Follman, David
2011-06-01
We describe the factors that go into the component choices for a short wavelength IR (SWIR) imager, which include the SWIR sensor, the lens, and the illuminator. We have shown the factors for reducing dark current, and shown that we can achieve well below 1.5 nA/cm2 for 15 μm devices at 7 °C. In addition, we have mated our InGaAs detector arrays to 640×512 readout integrated integrated circuits to make focal plane arrays (FPAs). The resulting FPAs are capable of imaging photon fluxes with wavelengths between 1 and 1.6 μm at low light levels. The dark current associated with these FPAs is extremely low, exhibiting a mean dark current density of 0.26 nA/cm2 at 0 °C. Noise due to the readout can be reduced from 95 to 57 electrons by using off-chip correlated double sampling. In addition, Aerius has developed laser arrays that provide flat illumination in scenes that are normally light-starved. The illuminators have 40% wall-plug efficiency and provide low-speckle illumination, and provide artifact-free imagery versus conventional laser illuminators.
Color and illuminance level of lighting can modulate willingness to eat bell peppers.
Hasenbeck, Aimee; Cho, Sungeun; Meullenet, Jean-François; Tokar, Tonya; Yang, Famous; Huddleston, Elizabeth A; Seo, Han-Seok
2014-08-01
Food products are often encountered under colored lighting, particularly in restaurants and retail stores. However, relatively little attention has been paid to whether the color of ambient lighting can affect consumers' motivation for consumption. This study aimed to determine whether color (Experiment 1) and illuminance level (Experiment 2) of lighting can influence consumers' liking of appearance and their willingness to eat bell peppers. For red, green, and yellow bell peppers, yellow and blue lighting conditions consistently increased participants' liking of appearance the most and the least, respectively. Participants' willingness to consume bell peppers increased the most under yellow lighting and the least under blue lighting. In addition, a dark condition (i.e. low level of lighting illuminance) decreased liking of appearance and willingness to eat the bell peppers compared to a bright condition (i.e. high level of lighting illuminance). Our findings demonstrate that lighting color and illuminance level can influence consumers' hedonic impression and likelihood to consume bell peppers. Furthermore, the influences of color and illuminance level of lighting appear to be dependent on the surface color of bell peppers. © 2013 Society of Chemical Industry.
Illumination discrimination in the absence of a fixed surface-reflectance layout
Radonjić, Ana; Ding, Xiaomao; Krieger, Avery; Aston, Stacey; Hurlbert, Anya C.; Brainard, David H.
2018-01-01
Previous studies have shown that humans can discriminate spectral changes in illumination and that this sensitivity depends both on the chromatic direction of the illumination change and on the ensemble of surfaces in the scene. These studies, however, always used stimulus scenes with a fixed surface-reflectance layout. Here we compared illumination discrimination for scenes in which the surface reflectance layout remains fixed (fixed-surfaces condition) to those in which surface reflectances were shuffled randomly across scenes, but with the mean scene reflectance held approximately constant (shuffled-surfaces condition). Illumination discrimination thresholds in the fixed-surfaces condition were commensurate with previous reports. Thresholds in the shuffled-surfaces condition, however, were considerably elevated. Nonetheless, performance in the shuffled-surfaces condition exceeded that attainable through random guessing. Analysis of eye fixations revealed that in the fixed-surfaces condition, low illumination discrimination thresholds (across observers) were predicted by low overall fixation spread and high consistency of fixation location and fixated surface reflectances across trial intervals. Performance in the shuffled-surfaces condition was not systematically related to any of the eye-fixation characteristics we examined for that condition, but was correlated with performance in the fixed-surfaces condition. PMID:29904786
Intraperitoneal photodynamic therapy of the rat CC531 adenocarcinoma.
Veenhuizen, R. B.; Marijnissen, J. P.; Kenemans, P.; Ruevekamp-Helmers, M. C.; 't Mannetje, L. W.; Helmerhorst, T. J.; Stewart, F. A.
1996-01-01
The goal of this study was to investigate the efficacy of photodynamic therapy (PDT) of a single tumour growing intraperitoneally. For this purpose the CC531 colon carcinoma, implanted in an intraperitoneal fat pad of Wag/RijA rats, was treated with intraperitoneal photodynamic therapy (IPPDT) using Photofrin as the photosensitiser. Two illumination techniques have been compared. An invasive illumination technique using Perspex blocks to illuminate 30 cm2 of the lower abdomen gave a significant delay in tumour growth with 25 J cm-2 applied 1 day after Photofrin. A minimally invasive illumination technique using a balloon catheter to illuminate 14 cm2 resulted in an equivalent growth delay with 75 J cm-2. The route of administration of the photosensitiser did not influence regrowth times of the tumour. Mitomycin C (MMC), a bioreductive agent, was used to exploit the known PDT-induced hypoxia. The combination of IPPDT with MMC resulted in an increased tumoricidal effect. In conclusion, IPPDT led to a significant growth delay for a single tumour implanted intraperitoneally and repetition of the PDT treatment was possible using a minimally invasive illumination technique. Repeated treatments resulted in increased tumour response. PMID:8645584
Physiological responses to illuminance and color temperature of lighting.
Kobayashi, H; Sato, M
1992-01-01
The present study was designed to examine the effects of illuminance and color temperature of room lighting. Four male students volunteered as subjects. Each of them performed a calculation task for 95 minutes under nine different lighting environments consisting of a combination of three levels of illuminance (320lx, 1000lx and 2000lx) and three levels of color temperature (3000 degrees K, 5000 degrees K and 7500 degrees K). Three types of fluorescent lamps were used as a light source to vary the color temperature. Blood pressure, critical flicker frequency (CFF) and accommodation time of eye movements were measured every 30 minutes during the task. The accommodation time was significantly influenced by the illuminance level and both the relaxation time and contraction time were prolonged under 2000lx. The diastolic blood pressure was significantly affected by the color temperature level and increased under 7500 degrees K. As for the CFF, the interaction between illuminance and color temperature was significant. These results mean that not only the illuminance but also color temperature produces physiological effects. The present study may be the first to recognize the effect of color temperature on the blood pressure.
Up-converted ultraviolet luminescence of Er3+:BaGd2ZnO5 phosphors for healthy illumination
NASA Astrophysics Data System (ADS)
Zhang, Ya; Cui, Qingzhi; Wang, Zhanyong; Liu, Gan; Tian, Tian; Xu, Jiayue
2016-09-01
Moderate level of exposure to the solar irradiation containing UV component is essential for health care. To incorporate the UV-emitting phosphors into the commercial YAG-based white light-emitting diode introduces the possibilities of healthy illumination to individuals' daily lives. 1 mol.% Er3+-doped BaGd2ZnO5 (BGZ) particles were synthesized via sol-gel method and efficient up-converted luminescence peaked at 380 nm was detected under 480 nm excitation. The mixed phosphors with varied mass ratio of Er3+:BGZ and Ce3+:YAG particles were encapsulated to form LEDs. The study of the LEDs indicated that the introduction of BGZ component favored the enhancement of color-rendering index and the neutralization of the white light emitting. The WLED with the BGZ/YAG ratio of 8:2 was recommendable for its excellent overall white light luminous performances and UV intensity of 84.55 mW/cm2. The UV illumination dose of the WLEDs with mixed YAG and BGZ was controllable by adjusting the ratio, the illumination distance and the illumination time. Er3+:BGZ phosphors are promising UVemitting phosphors for healthy indoor illumination.
Characterization of Lunar Polar Illumination from a Power System Perspective
NASA Technical Reports Server (NTRS)
Fincannon, James
2008-01-01
This paper presents the results of illumination analyses for the lunar south and north pole regions obtained using an independently developed analytical tool and two types of digital elevation models (DEM). One DEM was based on radar height data from Earth observations of the lunar surface and the other was a combination of the radar data with a separate dataset generated using Clementine spacecraft stereo imagery. The analysis tool enables the assessment of illumination at most locations in the lunar polar regions for any time and any year. Maps are presented for both lunar poles for the worst case winter period (the critical power system design and planning bottleneck) and for the more favorable best case summer period. Average illumination maps are presented to help understand general topographic trends over the regions. Energy storage duration maps are presented to assist in power system design. Average illumination fraction, energy storage duration, solar/horizon terrain elevation profiles and illumination fraction profiles are presented for favorable lunar north and south pole sites which have the potential for manned or unmanned spacecraft operations. The format of the data is oriented for use by power system designers to develop mass optimized solar and energy storage systems.
Rasta, Seyed Hossein; Partovi, Mahsa Eisazadeh; Seyedarabi, Hadi; Javadzadeh, Alireza
2015-01-01
To investigate the effect of preprocessing techniques including contrast enhancement and illumination correction on retinal image quality, a comparative study was carried out. We studied and implemented a few illumination correction and contrast enhancement techniques on color retinal images to find out the best technique for optimum image enhancement. To compare and choose the best illumination correction technique we analyzed the corrected red and green components of color retinal images statistically and visually. The two contrast enhancement techniques were analyzed using a vessel segmentation algorithm by calculating the sensitivity and specificity. The statistical evaluation of the illumination correction techniques were carried out by calculating the coefficients of variation. The dividing method using the median filter to estimate background illumination showed the lowest Coefficients of variations in the red component. The quotient and homomorphic filtering methods after the dividing method presented good results based on their low Coefficients of variations. The contrast limited adaptive histogram equalization increased the sensitivity of the vessel segmentation algorithm up to 5% in the same amount of accuracy. The contrast limited adaptive histogram equalization technique has a higher sensitivity than the polynomial transformation operator as a contrast enhancement technique for vessel segmentation. Three techniques including the dividing method using the median filter to estimate background, quotient based and homomorphic filtering were found as the effective illumination correction techniques based on a statistical evaluation. Applying the local contrast enhancement technique, such as CLAHE, for fundus images presented good potentials in enhancing the vasculature segmentation.
Using color histogram normalization for recovering chromatic illumination-changed images.
Pei, S C; Tseng, C L; Wu, C C
2001-11-01
We propose a novel image-recovery method using the covariance matrix of the red-green-blue (R-G-B) color histogram and tensor theories. The image-recovery method is called the color histogram normalization algorithm. It is known that the color histograms of an image taken under varied illuminations are related by a general affine transformation of the R-G-B coordinates when the illumination is changed. We propose a simplified affine model for application with illumination variation. This simplified affine model considers the effects of only three basic forms of distortion: translation, scaling, and rotation. According to this principle, we can estimate the affine transformation matrix necessary to recover images whose color distributions are varied as a result of illumination changes. We compare the normalized color histogram of the standard image with that of the tested image. By performing some operations of simple linear algebra, we can estimate the matrix of the affine transformation between two images under different illuminations. To demonstrate the performance of the proposed algorithm, we divide the experiments into two parts: computer-simulated images and real images corresponding to illumination changes. Simulation results show that the proposed algorithm is effective for both types of images. We also explain the noise-sensitive skew-rotation estimation that exists in the general affine model and demonstrate that the proposed simplified affine model without the use of skew rotation is better than the general affine model for such applications.
Ambient light-based optical biosensing platform with smartphone-embedded illumination sensor.
Park, Yoo Min; Han, Yong Duk; Chun, Hyeong Jin; Yoon, Hyun C
2017-07-15
We present a hand-held optical biosensing system utilizing a smartphone-embedded illumination sensor that is integrated with immunoblotting assay method. The smartphone-embedded illumination sensor is regarded as an alternative optical receiver that can replaces the conventional optical analysis apparatus because the illumination sensor can respond to the ambient light in a wide range of wavelengths, including visible and infrared. To demonstrate the biosensing applicability of our system employing the enzyme-mediated immunoblotting and accompanying light interference, various types of ambient light conditions including outdoor sunlight and indoor fluorescent were tested. For the immunoblotting assay, the biosensing channel generating insoluble precipitates as an end product of the enzymatic reaction is fabricated and mounted on the illumination sensor of the smartphone. The intensity of penetrating light arrives on the illumination sensor is inversely proportional to the amount of precipitates produced in the channel, and these changes are immediately analyzed and quantified via smartphone software. In this study, urinary C-terminal telopeptide fragment of type II collagen (uCTX-II), a biomarker of osteoarthritis diagnosis, was tested as a model analyte. The developed smartphone-based sensing system efficiently measured uCTX-II in the 0-5ng/mL concentration range with a high sensitivity and accuracy under various light conditions. These assay results show that the illumination sensor-based optical biosensor is suitable for point-of-care testing (POCT). Copyright © 2016 Elsevier B.V. All rights reserved.
Mao, Xianglong; Li, Hongtao; Han, Yanjun; Luo, Yi
2014-10-20
Designing an illumination system for a surface light source with a strict compactness requirement is quite challenging, especially for the general three-dimensional (3D) case. In accordance with the two key features of an expected illumination distribution, i.e., a well-controlled boundary and a precise illumination pattern, a two-step design method is proposed in this paper for highly compact 3D freeform illumination systems. In the first step, a target shape scaling strategy is combined with an iterative feedback modification algorithm to generate an optimized freeform optical system with a well-controlled boundary of the target distribution. In the second step, a set of selected radii of the system obtained in the first step are optimized to further improve the illuminating quality within the target region. The method is quite flexible and effective to design highly compact optical systems with almost no restriction on the shape of the desired target field. As examples, three highly compact freeform lenses with ratio of center height h of the lens and the maximum dimension D of the source ≤ 2.5:1 are designed for LED surface light sources to form a uniform illumination distribution on a rectangular, a cross-shaped and a complex cross pierced target plane respectively. High light control efficiency of η > 0.7 as well as low relative standard illumination deviation of RSD < 0.07 is obtained simultaneously for all the three design examples.
Advanced illumination control algorithm for medical endoscopy applications
NASA Astrophysics Data System (ADS)
Sousa, Ricardo M.; Wäny, Martin; Santos, Pedro; Morgado-Dias, F.
2015-05-01
CMOS image sensor manufacturer, AWAIBA, is providing the world's smallest digital camera modules to the world market for minimally invasive surgery and one time use endoscopic equipment. Based on the world's smallest digital camera head and the evaluation board provided to it, the aim of this paper is to demonstrate an advanced fast response dynamic control algorithm of the illumination LED source coupled to the camera head, over the LED drivers embedded on the evaluation board. Cost efficient and small size endoscopic camera modules nowadays embed minimal size image sensors capable of not only adjusting gain and exposure time but also LED illumination with adjustable illumination power. The LED illumination power has to be dynamically adjusted while navigating the endoscope over changing illumination conditions of several orders of magnitude within fractions of the second to guarantee a smooth viewing experience. The algorithm is centered on the pixel analysis of selected ROIs enabling it to dynamically adjust the illumination intensity based on the measured pixel saturation level. The control core was developed in VHDL and tested in a laboratory environment over changing light conditions. The obtained results show that it is capable of achieving correction speeds under 1 s while maintaining a static error below 3% relative to the total number of pixels on the image. The result of this work will allow the integration of millimeter sized high brightness LED sources on minimal form factor cameras enabling its use in endoscopic surgical robotic or micro invasive surgery.
Vimalanathan, Komalanathan; Ramesh Babu, Thangavelu
2014-01-01
The effect of indoor environment may have an influence on the performance, productivity health and well-being of office workers. Environmental factors such as indoor temperature and illumination have been investigated at three levels. A neurobehavioral test (NBT) has been proposed for the evaluation of office workersc performance. A field lab to emulate an office has been created. In controlled condition of environmental factors, the neurobehavioral test was conducted. The response time and the number of errors in each test have been recorded. A randomized block factorial design was used to analyze the responses of office worker's performance. The results revealed that the independent and interaction effect of temperature and illumination have significant effect on the office workers' performance. The effect of indoor room temperature has more influences than the effect of illumination. The effect of indoor temperature has 38.56% of contribution on the performance. The optimum levels of indoor temperature at 21°C and illumination at 1000 lux have improved the work performance and health of office workers. The indoor room temperature and illumination are more influence on the performance of the office workers. It may be concluded that the impact of indoor room temperature (38.56%) is more on the office worker's performance than the effect of illumination (19.91%). Further, it may be concluded that the optimum level of indoor room temperature (21°C) and illumination (1000lux) have improved the work performance, health and productivity of office workers.
Ito, Yuhei; Suzuki, Kyouichi; Ichikawa, Tsuyoshi; Watanabe, Yoichi; Sato, Taku; Sakuma, Jun; Saito, Kiyoshi
2018-06-12
Laser surgical microscopes should enable uniform illumination of the operative field, and require less luminous energy compared with existing xenon surgical microscopes. To examine the utility of laser illumination in fluorescence cerebral angiography. Fluorescein sodium (fluorescein) was used as a fluorescent dye. We first compared the clarity of cerebral blood flow images collected by fluorescence angiography between the laser illumination and xenon illumination methods. We then assessed use of the laser illuminator for simultaneous observation of blood flow and surrounding structures during fluorescence angiography. Furthermore, the study was designed to evaluate usefulness of the thus determined excitation light in clinical cases. Fluorescence angiography using blue light laser for excitation provided higher clarity and contrast blood flow images compared with using blue light generated from a xenon lamp. Further, illumination with excitation light consisting of a combination of 3 types of laser (higher level of blue light, no green light, and lower level of red light) enabled both blood flow and surrounding structures to be observed through the microscope directly by the surgeon. Laser-illuminated fluorescence angiography provides high clarity and contrast images of cerebral blood flow. Further, a laser providing strong blue light and weak red light for excitation light enables simultaneous visual observation of fluorescent blood flow and surrounding structures by the surgeon using a surgical microscope. Overall, these data suggest that laser surgical microscopes are useful for both ordinary operative manipulations and fluorescence angiography.
ERIC Educational Resources Information Center
Çaliskan, Ilke
2014-01-01
The aim of this study was to identify the needs of third grade classroom teaching students about science teaching course in terms of Parlett's Illuminative program evaluation model. Phenomographic research design was used in this study. Illuminative program evaluation model was chosen for this study in terms of its eclectic and process-based…
ERIC Educational Resources Information Center
Çaliskan, Ilke
2014-01-01
The aim of this study was to identify the needs of third grade classroom teaching students about science teaching course in terms of Parlett's Illuminative program evaluation model. Phenomographic research design was used in this study. Illuminative program evaluation model was chosen for this study in terms of its eclectic and process-based…
Asher, A; Shabtay, A; Brosh, A; Eitam, H; Agmon, R; Cohen-Zinder, M; Zubidat, A E; Haim, A
2015-01-01
Pineal melatonin (MLT) is produced at highest levels during the night, under dark conditions. We evaluated differences in MLT-concentration by comparing daytime versus night time milk samples, from two dairy farms with different night illumination conditions: (1) natural dark (Dark-Night); (2) short wavelength Artificial Light at Night (ALAN, Night-Illuminated). Samples were collected from 14 Israeli Holstein cows from each commercial dairy farm at 04:30 h ("Night-milk") 12:30 h ("Day-milk") and analyzed for MLT-concentration. In order to study the effects of night illumination conditions on cows circadian rhythms, Heart Rate (HR) daily rhythms were recorded. MLT-concentrations of Night-milk samples from the dark-night group were significantly (p < 0.001) higher than those of Night-illuminated conditions (30.70 ± 1.79 and 17.81 ± 0.33 pg/ml, respectively). Interestingly, night illumination conditions also affected melatonin concentrations at daytime where under Dark-Night conditions values are significantly (p < 0.001) higher than Night-Illuminated conditions, (5.36 ± 0.33 and 3.30 ± 0.18 pg/ml, respectively). There were no significant differences between the two treatments in the milk yield and milk composition except somatic cell count (SCC), which was significantly lower (p = 0.02) in the Dark-Night group compared with the Night-Illuminated group. Cows in both groups presented a significant (p < 0.01) HR daily rhythm, therefore we assume that in the night illuminated cows feeding and milking time are the "time keeper", while in the Dark-night cows, HR rhythms were entrained by the light/dark cycle. The higher MLT-concentration in Dark-night cows with the lower SCC values calls upon farmers to avoid exposure of cows to ALAN. Therefore, under Dark-night conditions milk quality will improve by lowering SCC values where separation between night and day of such milk can produce chrono-functional milk, naturally rich with MLT.
Ghate, Vinayak S; Ng, Kheng Siang; Zhou, Weibiao; Yang, Hyunsoo; Khoo, Gek Hoon; Yoon, Won-Byong; Yuk, Hyun-Gyun
2013-09-16
The antibacterial effect of light emitting diodes (LEDs) in the visible region (461, 521 and 642 nm) of the electromagnetic spectrum was investigated on Escherichia coli O157:H7, Salmonella typhimurium, Listeria monocytogenes and Staphylococcus aureus. The irradiances of the 461, 521 and 642 nm LEDs were 22.1, 16 and 25.4 mW/cm², respectively. Bacterial cultures suspended in tryptic soy broth were illuminated by 10-watt LEDs at a distance of 4.5 cm for 7.5h at 20, 15 and 10 °C. Regardless of the bacterial strains, bacterial inactivation was observed with the range of 4.6-5.2 logCFU/ml at 10 and 15 °C after illumination with the 461 nm LED, while illumination with the 521 nm LED resulted in only 1.0-2.0 log reductions after 7.5h. On the other hand, no antibacterial effect was observed using the 642 nm LED treatment. The photodynamic inactivation by 461 and 521 nm LEDs was found to be greater at the set temperatures of 10 and 15 °C than at 20 °C. The D-values for the four bacterial strains at 10 and 15 °C after the illumination of 461 nm LED ranged from 1.29 to 1.74 h, indicating that there was no significant difference in the susceptibility of the bacterial strains to the LED illumination between 10 and 15 °C, except for L. monocytogenes. Regardless of the illumination temperature, sublethal injury was observed in all bacterial strains during illumination with the 461 and the 521 nm LED and the percentage of injured cells increased as the treatment time increased. Thus, the results show that the antibacterial effect of the LEDs was highly dependent on the wavelength and the illumination temperature. This study suggests the potential of 461 and 521 nm LEDs in combination with chilling to be used as a novel food preservation technology. © 2013 Elsevier B.V. All rights reserved.
An extraocular non-invasive transscleral LED-endoilluminator for eye speculum integration.
Kölbl, Philipp Simon; Lindner, Christoph; Lingenfelder, Christian; Deuchler, Svenja; Singh, Pankaj; Koch, Frank; Hessling, Martin
2015-09-01
Conventional chandelier-endoilluminators used for pars-plana vitrectomy consist of a light-emitting tip attached to an optical fibre. The tip requires introduction into the ocular space through an incision. To achieve complete illumination of the intraocular space, the introduction of more than just one tip is sometimes necessary. An extraocular vitreoretinal LED-endoilluminator discussed in this paper represents a new approach to illuminate the intraocular space. The light source is integrated into a speculum and firmly apposed to the sclera. This approach offers the advantage of effectively illuminating the interior of the eye even though the procedure is non-invasive. Furthermore, this approach significantly reduces the risk of damage to the retina by phototoxic effects. A round white LED was used as a light source. By integrating the light source into a speculum, the LED was firmly held against the sclera. Thus, the ocular space was illuminated transsclerally. As a result, indirect uniform illumination of the complete intraocular space was achieved. The prototype was developed considering the relevant international standards. Porcine eyes were used because their properties are similar to those of human eyes. Porcine eyes could be acceptably illuminated with the selected LED. The LED-endoilluminator conforms with international standards for endoillumination. Thus, possible photochemical and thermal risks are considered and reduced to a minimum. A novel LED-endoilluminator which can be attached to a speculum was developed. The system does not need any connection to an external light source and, consequently, also avoids usage of an optical fibre. Regular and uniform illumination of the intraocular space was achieved by transmitted and scattered visible irradiation, avoiding an incision. The duration of potential light exposure, compared to existing illumination systems, can be significantly increased. This is also true when the illuminator is not directly placed over the pars-plana and the distance to the retina is reduced. Only a part of the light reaches the retina and the fraction of short wavelength becomes very small. Increased safety of the system results from now being able to increase the exposure time and reduce phototoxic stress to the retina.
A simple and low-cost structured illumination microscopy using a pico-projector
NASA Astrophysics Data System (ADS)
Özgürün, Baturay
2018-02-01
Here, development of a low-cost structured illumination microscopy (SIM) based on a pico-projector is presented. The pico-projector consists of independent red, green and blue LEDs that remove need for an external illumination source. Moreover, display element of the pico-projector serves as a pattern generating spatial light modulator. A simple lens group is employed to couple light from the projector to an epi-illumination port of a commercial microscope system. 2D sub SIM images are acquired and synthesized to surpass the diffraction limit using 40x (0.75 NA) objective. Resolution of the reconstructed SIM images is verified with a dye-and-object object and a fixed cell sample.
Chromatic perception of non-invasive lighting of cave paintings
NASA Astrophysics Data System (ADS)
Zoido, Jesús; Vazquez, Daniel; Álvarez, Antonio; Bernabeu, Eusebio; García, Ángel; Herraez, Juán A.; del Egido, Marian
2009-08-01
This work is intended to deal with the problems which arise when illuminanting Paleolithic cave paintings. We have carried out the spectral and colorimetric characterization of some paintings located in the Murcielagos (bats) cave (Zuheros, Córdoba, Spain). From this characterization, the chromatic changes produced under different lighting conditions are analysed. The damage function is also computed for the different illuminants used. From the results obtained, it is proposed an illuminant whose spectral distribution diminishes the damage by minimizing the absorption of radiation and optimises the color perception of the paintings in this cave. The procedure followed in this study can be applied to optimise the lighting systems used when illuminating any other art work
Metal-Free Photocatalyst with Visible-Light-Driven Post-Illumination Catalytic Memory.
Zhang, Qi; Wang, Hua; Li, Zhangliang; Geng, Cong; Leng, Jinhui
2017-07-05
A novel metal-free photocatalyst with post-illumination catalytic memory was fabricated by the graphitic carbon nitride (g-C 3 N 4 ), carbon nanotubes (CNTs), and graphene (Gr), in which g-C 3 N 4 acts as an efficient photocatalyst and the CNTs and Gr act as supercapacitors. The removal of phenol was achieved in the dark by post-illumination catalytic memory because the photocatalyst could store a portion of its photoactivity via photogenerated electrons in the CNTs and Gr under visible-light illumination and then release the electrons again in the dark. Therefore, this metal-free photocatalyst is capable of operation in the dark for a broad range of applications.
Reflector system for a lighting fixture
Siminovitch, Michael J.; Page, Erik; Gould, Carl T.
1998-01-01
Disclosed herein is a reflector system for a lighting fixture having a illumination source surrounded by an envelope. The reflector system includes a first reflector surrounding the illumination source. The reflector system also includes a second reflector which is non-contiguous with the first reflector and which surrounds the illumination source. The illumination source creates light rays which are reflected by the first and second reflectors. The first reflector directs light rays toward the center line of the fixture. However, the reflected rays despite being so reflected do not substantially intersect the envelope. The reflected light rays from the second reflector being directed so that they diverge from the center line of the fixture avoiding intersection with the semi-transparent envelope.
Reflector system for a lighting fixture
Siminovitch, Michael J.; Page, Erik; Gould, Carl T.
2001-01-01
Disclosed herein is a reflector system for a lighting fixture having a illumination source surrounded by an envelope. The reflector system includes a first reflector surrounding the illumination source. The reflector system also includes a second reflector which is non-contiguous with the first reflector and which surrounds the illumination source. The illumination source creates light rays which are reflected by the first and second reflectors. The first reflector directs light rays toward the center line of the fixture. However, the reflected rays despite being so reflected do not substantially intersect the envelope. The reflected light rays from the second reflector being directed so that they diverge from the center line of the fixture avoiding intersection with the semi-transparent envelope.
Lee, Robert J.; Smithson, Hannah E.
2016-01-01
We tested whether surface specularity alone supports operational color constancy – the ability to discriminate changes in illumination or reflectance. Observers viewed short animations of illuminant or reflectance changes in rendered scenes containing a single spherical surface, and were asked to classify the change. Performance improved with increasing specularity, as predicted from regularities in chromatic statistics. Peak performance was impaired by spatial rearrangements of image pixels that disrupted the perception of illuminated surfaces, but was maintained with increased surface complexity. The characteristic chromatic transformations that are available with non-zero specularity are useful for operational color constancy, particularly if accompanied by appropriate perceptual organisation. PMID:26974938
Study of polarization phenomena in Schottky CdTe diodes using infrared light illumination
NASA Astrophysics Data System (ADS)
Sato, Goro; Fukuyama, Taro; Watanabe, Shin; Ikeda, Hirokazu; Ohta, Masayuki; Ishikawa, Shin'nosuke; Takahashi, Tadayuki; Shiraki, Hiroyuki; Ohno, Ryoichi
2011-10-01
Schottky CdTe diode detectors suffer from a polarization phenomenon, which is characterized by degradation of the spectral properties over time following exposure to high bias voltage. This is considered attributable to charge accumulation at deep acceptor levels. A Schottky CdTe diode was illuminated with an infrared light for a certain period during a bias operation, and two opposite behaviors emerged. The detector showed a recovery when illuminated after the bias-induced polarization had completely progressed. Conversely, when the detector was illuminated before the emergence of bias-induced polarization, the degradation of the spectral properties was accelerated. Interpretation of these effects and discussion on the energy level of deep acceptors are presented.
Astor-Stetson, E; Lane, S
1991-08-01
Reflectance contrast (i.e., black as compared to grey figures on white ground) and display illumination were manipulated to vary the brightness contrast of Wundt-Hering figures. 16 college students and 16 older adults were presented with high, medium, and low reflectance contrast figures. For half the participants, display illumination was manipulated by covering the figures with a .5 yellow neutral density filter. Magnitude of the illusion increased significantly with increased reflectance contrast for college students, and college students were significantly more susceptible to the high contrast figures than were older adults. Display illumination had no effect on the performance of either group.
NASA Technical Reports Server (NTRS)
Mullican, R. C.; Hayes, B. C.
1991-01-01
Preliminary results of research conducted in the late 1970's indicate that perceptual qualities of an enclosure can be influenced by the distribution of illumination within the enclosure. Subjective impressions such as spaciousness, perceptual clarity, and relaxation or tenseness, among others, appear to be related to different combinations of surface luminance. A prototype indirect ambient illumination system was developed which will allow crew members to alter surface luminance distributions within an enclosed module, thus modifying perceptual cues to match crew preferences. A traditional lensed direct lighting system was compared to the prototype utilizing the full-scale mockup of Space Station Freedom developed by Marshall Space Flight Center. The direct lensed system was installed in the habitation module with the indirect prototype deployed in the U.S. laboratory module. Analysis centered on the illuminance and luminance distributions resultant from these systems and the implications of various luminaire spacing options. All test configurations were evaluated for compliance with NASA Standard 3000, Man-System Integration Standards.
Specimen illumination apparatus with optical cavity for dark field illumination
Pinkel, Daniel; Sudar, Damir; Albertson, Donna
1999-01-01
An illumination apparatus with a specimen slide holder, an illumination source, an optical cavity producing multiple reflection of illumination light to a specimen comprising a first and a second reflective surface arranged to achieve multiple reflections of light to a specimen is provided. The apparatus can further include additional reflective surfaces to achieve the optical cavity, a slide for mounting the specimen, a coverslip which is a reflective component of the optical cavity, one or more prisms for directing light within the optical cavity, antifading solutions for improving the viewing properties of the specimen, an array of materials for analysis, fluorescent components, curved reflective surfaces as components of the optical cavity, specimen detection apparatus, optical detection equipment, computers for analysis of optical images, a plane polarizer, fiberoptics, light transmission apertures, microscopic components, lenses for viewing the specimen, and upper and lower mirrors above and below the specimen slide as components of the optical cavity. Methods of using the apparatus are also provided.
NASA Astrophysics Data System (ADS)
Rakleviciene, D.; Svegzdiene, D.; Tamulaitis, G.; Zukauskas, A.
2005-08-01
The growth rate and orientation of cress seedlings in response to the direction of illumination under clino- rotation were investigated at the initial stage of intensive hypocotyl elongation. Roots and hypocotyls growing in normal gravity conditions (1 g) and under clino-rotation at 3 rpm were illuminated with red (660 nm) or blue (450 nm) light from light-emitting diodes (LEDs). Unidirectional illumination in the direction opposite to the gravity vector promoted the growth rate of roots. Inhibition of gravitropism by clino-rotation reduced the growth of roots and stimulated the elongation of hypocotyls in both red and blue light. Illumination of roots invoked changes in the formation of gravisensing cells in the columella. Illumination under clino-rotation stimulated root statocyte growth and increased the number of amyloplasts in cells of the 3rd-6th columella rows. Also, an increase in the columella cell area, mainly caused by cell elongation in blue light and by enhanced radial growth in red light, was observed.
Inoue, Tomoyuki; Oshima, Yusuke; Hori, Yuich; Maeda, Naoyuki
2010-08-01
A new 25-gauge illuminated anterior chamber maintainer composed of a 25-gauge infusion cannula through which a 29-gauge chandelier fiber probe passes was developed for use during Descemet stripping automated endothelial keratoplasty to treat patients with advanced bullous keratopathy. This device, which is compatible with a xenon or mercury vapor illuminator to generate powerful wide-angle illumination from the cone-shaped chandelier fiber tip, is self-retained at the corneal limbus after insertion of the infusion cannula through a corneal side port. Because of its bifunctionality, that is, bright illumination and adequate irrigation flow, excellent visibility with stable anterior chamber maintenance can be concurrently obtained for Descemet stripping, endothelial graft insertion, and subsequent intraocular manipulations without the need for use of a biologic staining technique or ophthalmic viscosurgical products even in patients with severe corneal haze. This new device facilitates safe and simple intraocular manipulation during Descemet stripping automated endothelial keratoplasty.
A Context-Aware Method for Authentically Simulating Outdoors Shadows for Mobile Augmented Reality.
Barreira, Joao; Bessa, Maximino; Barbosa, Luis; Magalhaes, Luis
2018-03-01
Visual coherence between virtual and real objects is a major issue in creating convincing augmented reality (AR) applications. To achieve this seamless integration, actual light conditions must be determined in real time to ensure that virtual objects are correctly illuminated and cast consistent shadows. In this paper, we propose a novel method to estimate daylight illumination and use this information in outdoor AR applications to render virtual objects with coherent shadows. The illumination parameters are acquired in real time from context-aware live sensor data. The method works under unprepared natural conditions. We also present a novel and rapid implementation of a state-of-the-art skylight model, from which the illumination parameters are derived. The Sun's position is calculated based on the user location and time of day, with the relative rotational differences estimated from a gyroscope, compass and accelerometer. The results illustrated that our method can generate visually credible AR scenes with consistent shadows rendered from recovered illumination.
Optically controlled polarization in highly oriented ferroelectric thin films
NASA Astrophysics Data System (ADS)
Borkar, Hitesh; Tomar, M.; Gupta, Vinay; Katiyar, Ram S.; Scott, J. F.; Kumar, Ashok
2017-08-01
The out-of-plane and in-plane polarization of (Pb0.6Li0.2Bi0.2)(Zr0.2Ti0.8)O3 (PLBZT) thin film has been studied in the dark and under illumination from a weak light source of a comparable bandgap. A highly oriented PLBZT thin film was grown on a LaNiO3/LaAlO3 substrate by pulsed laser deposition; it showed well-saturated polarization which was significantly enhanced under light illumination. We employed two configurations for polarization characterization: the first deals with out-of-plane polarization with a single capacitor under investigation, whereas the second uses two capacitors connected in series via the bottom electrode. Two different configurations were illuminated using different energy sources and their effects were studied. The latter configuration shows a significant change in polarization under light illumination that may provide an extra degree of freedom for device miniaturization. The polarization was also tested using positive-up and negative-down measurements, confirming robust polarization and its switching under illumination.
Back-side hydrogenation technique for defect passivation in silicon solar cells
Sopori, Bhushan L.
1994-01-01
A two-step back-side hydrogenation process includes the steps of first bombarding the back side of the silicon substrate with hydrogen ions with intensities and for a time sufficient to implant enough hydrogen atoms into the silicon substrate to potentially passivate substantially all of the defects and impurities in the silicon substrate, and then illuminating the silicon substrate with electromagnetic radiation to activate the implanted hydrogen, so that it can passivate the defects and impurities in the substrate. The illumination step also annihilates the hydrogen-induced defects. The illumination step is carried out according to a two-stage illumination schedule, the first or low-power stage of which subjects the substrate to electromagnetic radiation that has sufficient intensity to activate the implanted hydrogen, yet not drive the hydrogen from the substrate. The second or high-power illumination stage subjects the substrate to higher intensity electromagnetic radiation, which is sufficient to annihilate the hydrogen-induced defects and sinter/alloy the metal contacts.
Back-side hydrogenation technique for defect passivation in silicon solar cells
Sopori, B.L.
1994-04-19
A two-step back-side hydrogenation process includes the steps of first bombarding the back side of the silicon substrate with hydrogen ions with intensities and for a time sufficient to implant enough hydrogen atoms into the silicon substrate to potentially passivate substantially all of the defects and impurities in the silicon substrate, and then illuminating the silicon substrate with electromagnetic radiation to activate the implanted hydrogen, so that it can passivate the defects and impurities in the substrate. The illumination step also annihilates the hydrogen-induced defects. The illumination step is carried out according to a two-stage illumination schedule, the first or low-power stage of which subjects the substrate to electromagnetic radiation that has sufficient intensity to activate the implanted hydrogen, yet not drive the hydrogen from the substrate. The second or high-power illumination stage subjects the substrate to higher intensity electromagnetic radiation, which is sufficient to annihilate the hydrogen-induced defects and sinter/alloy the metal contacts. 3 figures.
NASA Astrophysics Data System (ADS)
Krishnaswami, Venkataraman; De Luca, Giulia M. R.; Breedijk, Ronald M. P.; Van Noorden, Cornelis J. F.; Manders, Erik M. M.; Hoebe, Ron A.
2017-02-01
Fluorescence microscopy is an important tool in biomedical imaging. An inherent trade-off lies between image quality and photodamage. Recently, we have introduced rescan confocal microscopy (RCM) that improves the lateral resolution of a confocal microscope down to 170 nm. Previously, we have demonstrated that with controlled-light exposure microscopy, spatial control of illumination reduces photodamage without compromising image quality. Here, we show that the combination of these two techniques leads to high resolution imaging with reduced photodamage without compromising image quality. Implementation of spatially-controlled illumination was carried out in RCM using a line scanning-based approach. Illumination is spatially-controlled for every line during imaging with the help of a prediction algorithm that estimates the spatial profile of the fluorescent specimen. The estimation is based on the information available from previously acquired line images. As a proof-of-principle, we show images of N1E-115 neuroblastoma cells, obtained by this new setup with reduced illumination dose, improved resolution and without compromising image quality.
NASA Astrophysics Data System (ADS)
Shi, Zhemin; Taguchi, Dai; Manaka, Takaaki; Iwamoto, Mitsumasa
2016-04-01
The details of turnover process of spontaneous polarization and associated carrier motions in indium-tin oxide/poly-(vinylidene-trifluoroethylene)/pentacene/Au capacitor were analyzed by coupling displacement current measurement (DCM) and electric-field-induced optical second-harmonic generation (EFISHG) measurement. A model was set up from DCM results to depict the relationship between electric field in semiconductor layer and applied external voltage, proving that photo illumination effect on the spontaneous polarization process lied in variation of semiconductor conductivity. The EFISHG measurement directly and selectively probed the electric field distribution in semiconductor layer, modifying the model and revealing detailed carrier behaviors involving photo illumination effect, dipole reversal, and interfacial charging in the device. A further decrease of DCM current in the low voltage region under illumination was found as the result of illumination effect, and the result was argued based on the changing of the total capacitance of the double-layer capacitors.
Structural and optical properties of annealed and illuminated (Ag3AsS3)0.6(As2S3)0.4 thin films
NASA Astrophysics Data System (ADS)
Studenyak, I. P.; Neimet, Yu. Yu.; Rati, Y. Y.; Stanko, D.; Kranjčec, M.; Kökényesi, S.; Daróci, L.; Bohdan, R.
2014-11-01
(Ag3AsS3)0.6(As2S3)0.4 thin films were deposited upon a quartz substrate by rapid thermal evaporation. Structural studies of the as-deposited, annealed and illuminated films were performed using XRD, scanning electron and atomic force microscopies. Surfaces of all the films were found to be covered with Ag-rich crystalline micrometer sized cones. Thermal annealing leads to mechanical deformation of part of the cones and their detachment from the base film surface while the laser illumination leads to the new formations appearance on the surface of thin films. The spectroscopic studies of optical transmission spectra for as-deposited, annealed and illuminated thin films were carried out. The optical absorption spectra in the region of its exponential behaviour were analysed, the dispersion dependences of refractive index as well as their variation after annealing and illumination were investigated.
Beam uniformity analysis of infrared laser illuminators
NASA Astrophysics Data System (ADS)
Allik, Toomas H.; Dixon, Roberta E.; Proffitt, R. Patrick; Fung, Susan; Ramboyong, Len; Soyka, Thomas J.
2015-02-01
Uniform near-infrared (NIR) and short-wave infrared (SWIR) illuminators are desired in low ambient light detection, recognition, and identification of military applications. Factors that contribute to laser illumination image degradation are high frequency, coherent laser speckle and low frequency nonuniformities created by the laser or external laser cavity optics. Laser speckle analysis and beam uniformity improvements have been independently studied by numerous authors, but analysis to separate these two effects from a single measurement technique has not been published. In this study, profiles of compact, diode laser NIR and SWIR illuminators were measured and evaluated. Digital 12-bit images were recorded with a flat-field calibrated InGaAs camera with measurements at F/1.4 and F/16. Separating beam uniformity components from laser speckle was approximated by filtering the original image. The goal of this paper is to identify and quantify the beam quality variation of illumination prototypes, draw awareness to its impact on range performance modeling, and develop measurement techniques and methodologies for military, industry, and vendors of active sources.
NASA Astrophysics Data System (ADS)
Meola, Joseph; Absi, Anthony; Islam, Mohammed N.; Peterson, Lauren M.; Ke, Kevin; Freeman, Michael J.; Ifaraguerri, Agustin I.
2014-06-01
Hyperspectral imaging systems are currently used for numerous activities related to spectral identification of materials. These passive imaging systems rely on naturally reflected/emitted radiation as the source of the signal. Thermal infrared systems measure radiation emitted from objects in the scene. As such, they can operate at both day and night. However, visible through shortwave infrared systems measure solar illumination reflected from objects. As a result, their use is limited to daytime applications. Omni Sciences has produced high powered broadband shortwave infrared super-continuum laser illuminators. A 64-watt breadboard system was recently packaged and tested at Wright-Patterson Air Force Base to gauge beam quality and to serve as a proof-of-concept for potential use as an illuminator for a hyperspectral receiver. The laser illuminator was placed in a tower and directed along a 1.4km slant path to various target materials with reflected radiation measured with both a broadband camera and a hyperspectral imaging system to gauge performance.
NASA Technical Reports Server (NTRS)
Obenschain, A. F.; Faith, T. J.
1973-01-01
Emperical equations have been derived from measurements of solar cell photovoltaic characteristics relating light generated current, IL, and open circuit voltage, VO, to cell temperature, T, intensity of illumination, W, and 1 Mev electron fluence, phi both 2 ohm-cm and 10 ohm-cm cells were tested. The temperature dependency of IL is similar for both resistivities at 140mw/sq cm; at high temperature the coefficient varies with fluence as phi 0.18, while at low temperatures the coefficient is relatively independent of fluence. Fluence dependent degration causes a decrease in IL at a rate proportional to phi 0.153 for both resistivities. At all intensities other than 560 mw/sq cm, a linear dependence of IL on illumination was found. The temperature coefficient of voltage was, to a good approximation, independent of both temperature and illumination for both resistivities. Illumination dependence of VOC was logarithmic, while the decrease with fluence of VOC varied as phi 0.25 for both resistivities.
The twilight envelope: a user-centered approach to describing roadway illumination at night.
Andre, J; Owens, D A
2001-01-01
Visual recognition functions, such as acuity and contrast sensitivity, deteriorate rapidly over the declining luminances found during civil twilight. Thus civil twilight, a critical part of the transition between daylight and darkness, represents lighting conditions that may be useful to describe artificial illumination. Automotive headlamps project a three-dimensional beam that ranges from illumination levels comparable to daylight at the vehicle to the dark limit of civil twilight (3.3 1x) at some distance ahead. This twilight envelope is characterized as a distance beyond which foveal visual functions are severely impaired, and thus it provides a general, functional description of the useful extent of the headlamp beam. This user-centered approach to describing illumination is useful for characterizing visibility when driving at night or in other artificially lit environments. This paper discusses the twilight envelope approach and its application to intervehicle variations in headlamp systems. Actual or potential applications of this research include user-centered description of artificial illumination and driver/pedestrian safety education.
Non-contact assessment of melanin distribution via multispectral temporal illumination coding
NASA Astrophysics Data System (ADS)
Amelard, Robert; Scharfenberger, Christian; Wong, Alexander; Clausi, David A.
2015-03-01
Melanin is a pigment that is highly absorptive in the UV and visible electromagnetic spectra. It is responsible for perceived skin tone, and protects against harmful UV effects. Abnormal melanin distribution is often an indicator for melanoma. We propose a novel approach for non-contact melanin distribution via multispectral temporal illumination coding to estimate the two-dimensional melanin distribution based on its absorptive characteristics. In the proposed system, a novel multispectral, cross-polarized, temporally-coded illumination sequence is synchronized with a camera to measure reflectance under both multispectral and ambient illumination. This allows us to eliminate the ambient illumination contribution from the acquired reflectance measurements, and also to determine the melanin distribution in an observed region based on the spectral properties of melanin using the Beer-Lambert law. Using this information, melanin distribution maps can be generated for objective, quantitative assessment of skin type of individuals. We show that the melanin distribution map correctly identifies areas with high melanin densities (e.g., nevi).
NASA Technical Reports Server (NTRS)
Taranik, J. V.; Slemmons, D. B.; Bell, E. J.; Borengasser, M.; Lugaski, T. P.; Vreeland, H.; Vreeland, P.; Kleiner, E.; Peterson, F. F.; Kleiforth, H.
1984-01-01
The measurement capability provided by the Shuttle Imaging Radar (SIR-B) was used to determine: (1) the relationships between radar illumination geometry and depth of penetration in different climatic and physiographic environments in Nevada; and, (2) the relationships between radar illumination geometry and detection and analysis of structural features in different climatic and physiographic environments in Nevada.
Pigeons' Memory for Number of Events: Effects of Intertrial Interval and Delay Interval Illumination
ERIC Educational Resources Information Center
Hope, Chris; Santi, Angelo
2004-01-01
In Experiment 1, pigeons were trained at a 0-s baseline delay to discriminate sequences of light flashes (illumination of the feeder) that varied in number but not time (2f/4s and 8f/4s). During training, the intertrial interval was illuminated by the houselight for Group Light, but it was dark for Group Dark. Testing conducted with dark delay…
Illumination in diverse codimensions
NASA Technical Reports Server (NTRS)
Banks, David C.
1994-01-01
This paper derives a model of diffuse and specular illumination in arbitrarily large dimensions, based on a few characteristics of material and light in three-space. It then describes how to adjust for the anomaly of excess brightness in large codimensions. If a surface is grooved or furry, it can be illuminated with a hybrid model that incorporates both the one dimensional geometry (the grooves or fur) and the two dimensional geometry (the surface).
Color appearance of familiar objects: effects of object shape, texture, and illumination changes.
Olkkonen, Maria; Hansen, Thorsten; Gegenfurtner, Karl R
2008-05-26
People perceive roughly constant surface colors despite large changes in illumination. The familiarity of colors of some natural objects might help achieve this feat through direct modulation of the objects' color appearance. Research on memory colors and color appearance has yielded controversial results and due to the employed methods has often confounded perceptual with semantic effects. We studied the effect of memory colors on color appearance by presenting photographs of fruit on a monitor under various simulated illuminations and by asking observers to make either achromatic or typical color settings without placing demands on short-term memory or semantic processing. In a control condition, we presented photographs of 3D fruit shapes without texture and 2D outline shapes. We found that (1) achromatic settings for fruit were systematically biased away from the gray point toward the opposite direction of a fruit's memory color; (2) the strength of the effect depended on the degree of naturalness of the stimuli; and (3) the effect was evident under all tested illuminations, being strongest for illuminations whose chromaticity was closest to the stimulus chromaticity. We conclude that the visual identity of an object has a measurable effect on color perception, and that this effect is robust under illuminant changes, indicating its potential significance as an additional mechanism for color constancy.
Quantitative studies of animal colour constancy: using the chicken as model
2016-01-01
Colour constancy is the capacity of visual systems to keep colour perception constant despite changes in the illumination spectrum. Colour constancy has been tested extensively in humans and has also been described in many animals. In humans, colour constancy is often studied quantitatively, but besides humans, this has only been done for the goldfish and the honeybee. In this study, we quantified colour constancy in the chicken by training the birds in a colour discrimination task and testing them in changed illumination spectra to find the largest illumination change in which they were able to remain colour-constant. We used the receptor noise limited model for animal colour vision to quantify the illumination changes, and found that colour constancy performance depended on the difference between the colours used in the discrimination task, the training procedure and the time the chickens were allowed to adapt to a new illumination before making a choice. We analysed literature data on goldfish and honeybee colour constancy with the same method and found that chickens can compensate for larger illumination changes than both. We suggest that future studies on colour constancy in non-human animals could use a similar approach to allow for comparison between species and populations. PMID:27170714
NASA Astrophysics Data System (ADS)
Mo, Weirong; Mohan, Rachit; Li, Weizhi; Zhang, Xu; Sellke, Eric W.; Fan, Wensheng; DiMaio, J. Michael; Thatcher, Jeffery E.
2015-02-01
We present a non-contact, reflective photoplethysmogram (PPG) imaging method and a prototype system for identifying the presence of dermal burn wounds during a burn debridement surgery. This system aims to provide assistance to clinicians and surgeons in the process of dermal wound management and wound triage decisions. We examined the system variables of illumination uniformity and intensity and present our findings. An LED array, a tungsten light source, and eventually high-power LED emitters were studied as illumination methods for our PPG imaging device. These three different illumination sources were tested in a controlled tissue phantom model and an animal burn model. We found that the low heat and even illumination pattern using high power LED emitters provided a substantial improvement to the collected PPG signal in our animal burn model. These improvements allow the PPG signal from different pixels to be comparable in both time-domain and frequency-domain, simplify the illumination subsystem complexity, and remove the necessity of using high dynamic range cameras. Through the burn model output comparison, such as the blood volume in animal burn data and controlled tissue phantom model, our optical improvements have led to more clinically applicable images to aid in burn assessment.
Micromilled optical elements for edge-lit illumination panels
NASA Astrophysics Data System (ADS)
Ronny, Rahima Afrose; Knopf, George K.; Bordatchev, Evgueni; Nikumb, Suwas
2013-04-01
Edge-lit light guide panels (LGPs) with micropatterned surfaces represent a new technology for developing small- and medium-sized illumination sources for application such as automotive, residential lighting, and advertising displays. The shape, density, and spatial distribution of the micro-optical structures (MOSs) imprinted on the transparent LGP must be selected to achieve high brightness and uniform luminance over the active surface. We examine how round-tip cylindrical MOSs fabricated by precision micromilling can be used to create patterned surfaces on low-cost transparent polymethyl-methacrylate substrates for high-intensity illumination applications. The impact of varying the number, pitch, spatial distribution, and depth of the optical microstructures on lighting performance is initially investigated using LightTools™ simulation software. To illustrate the microfabrication process, several 100×100×6 mm3 LGP prototypes are constructed and tested. The prototypes include an "optimized" array of MOSs that exhibit near-uniform illumination (approximately 89%) across its active light-emitting surface. Although the average illumination was 7.3% less than the value predicted from numerical simulation, it demonstrates how LGPs can be created using micromilling operations. Customized MOS arrays with a bright rectangular pattern near the center of the panel and a sequence of MOSs that illuminate a predefined logo are also presented.
To compute lightness, illumination is not estimated, it is held constant.
Gilchrist, Alan L
2018-05-03
The light reaching the eye from a surface does not indicate the black-gray-white shade of a surface (called lightness) because the effects of illumination level are confounded with the reflectance of the surface. Rotating a gray paper relative to a light source alters its luminance (intensity of light reaching the eye) but the lightness of the paper remains relatively constant. Recent publications have argued, as had Helmholtz (1866/1924), that the visual system unconsciously estimates the direction and intensity of the light source. We report experiments in which this theory was pitted against an alternative theory according to which illumination level and surface reflectance are disentangled by comparing only those surfaces that are equally illuminated, in other words, by holding illumination level constant. A 3-dimensional scene was created within which the rotation of a target surface would be expected to become darker gray according to the lighting estimation theory, but lighter gray according to the equi-illumination comparison theory, with results clearly favoring the latter. In a further experiment cues held to indicate light source direction (cast shadows, attached shadows, and glossy highlights) were completely eliminated and yet this had no effect on the results. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
NASA Astrophysics Data System (ADS)
Loro, Stephen Lee
This study was designed to examine moon illumination, moon angle, cloud cover, sky glow, and Night Vision Goggle (NVG) flight performance to determine possible effects. The research was a causal-comparative design. The sample consisted of 194 Fort Rucker Initial Entry Rotary Wing NVG flight students being observed by 69 NVG Instructor Pilots. The students participated in NVG flight training from September 1992 through January 1993. Data were collected using a questionnaire. Observations were analyzed using a Kruskal-Wallis one-way analysis of variance and a Wilcox matched pairs signed-ranks test for difference. Correlations were analyzed using Pearson's r. The analyses results indicated that performance at high moon illumination levels is superior to zero moon illumination, and in most task maneuvers, superior to >0%--50% moon illumination. No differences were found in performance at moon illumination levels above 50%. Moon angle had no effect on night vision goggle flight performance. Cloud cover and sky glow have selective effects on different maneuvers. For most task maneuvers, cloud cover does not affect performance. Overcast cloud cover had a significant effect on seven of the 14 task maneuvers. Sky glow did not affect eight out of 14 task maneuvers at any level of sky glow.
NASA Astrophysics Data System (ADS)
Shabani, H.; Doblas, A.; Saavedra, G.; Preza, C.
2018-02-01
Three-dimensional (3D) structured illumination (SI) patterns that include lateral and axial variations have attracted more attention recently as their use in fluorescence microscope enhances the 3D resolution of the native imaging system. 3D SI patterns have already been created by interfering three mutually-coherent waves using a diffraction grating or some electro-optical devices such as spatial light modulators. Here, an interesting approach to generate a 3D SI pattern of tunable modulation frequency is shown. Our proposed illumination system is based on the incoherent illumination of a Fresnel biprism using several equidistant linear sources (i.e., slits). Previously, we investigated and compared numerically this tunable SI microscopy (SIM) system with the one achieved with three-wave interference. In this contribution, we implement our proposed incoherent 3D SIM system of tunable-frequency in an open-setup. We evaluate the axial confinement of the illumination pattern obtained with this system by recording the SI pattern using a mirror sample and different number of slits and compare these data with simulation results. Moreover, we verify that with a higher number of slits used, the axial confinement of the pattern increases, and consequently, the system's optical sectioning capability improves.
NASA Astrophysics Data System (ADS)
Zhao, Zhili; Zhang, Honghai; Zheng, Huai; Liu, Sheng
2018-03-01
In light-emitting diode (LED) array illumination (e.g. LED backlighting), obtainment of high uniformity in the harsh condition of the large distance height ratio (DHR), extended source and near field is a key as well as challenging issue. In this study, we present a new reversing freeform lens design algorithm based on the illuminance distribution function (IDF) instead of the traditional light intensity distribution, which allows uniform LED illumination in the above mentioned harsh conditions. IDF of freeform lens can be obtained by the proposed mathematical method, considering the effects of large DHR, extended source and near field target at the same time. In order to prove the claims, a slim direct-lit LED backlighting with DHR equal to 4 is designed. In comparison with the traditional lenses, illuminance uniformity of LED backlighting with the new lens increases significantly from 0.45 to 0.84, and CV(RMSE) decreases dramatically from 0.24 to 0.03 in the harsh condition. Meanwhile, luminance uniformity of LED backlighting with the new lens is obtained as high as 0.92 at the condition of extended source and near field. This new method provides a practical and effective way to solve the problem of large DHR, extended source and near field for LED array illumination.
Muramoto, Hideyuki; Shimamoto, Kazuhiro; Ikeda, Mitsuru; Koyama, Kazuyuki; Fukushima, Hiromichi; Ishigaki, Takeo
2006-06-01
The influence of monitor brightness and room illumination on soft-copy diagnosis by both cathode-ray tube (CRT) monitor and liquid crystal display (LCD) was evaluated and compared using a contrast-detail phantom. Nine observers (7 radiologists and 2 radiological technicians) interpreted six types of electronically generated contrast-detail phantom images using a 21-inch CRT (2,048x2,560) and a 21-inch LCD (2,048x2,560) under 6 kinds of viewing conditions, i.e. monitor brightness of 330 cd/m2 or 450 cd/m2, and room illumination of 20, 100 or 420 lux at the center of the display. Observers were requested to determine the visible borderline of the objects. Between 330 cd/m2 and 450 cd/m2, no significant difference in the visible area was found under any of the three lighting conditions. However, in two low-contrast phantom images, the visible area on the LCD was significantly larger than that on the CRT, independent of both monitor brightness and room illumination. (p<0.05). The effect of room illumination was not significant, suggesting that the use of LCD at high room illumination is acceptable.
The Effect of Illumination on Stereo DTM Quality: Simulations in Support of Europa Exploration
NASA Astrophysics Data System (ADS)
Kirk, R. L.; Howington-Kraus, E.; Hare, T. M.; Jorda, L.
2016-06-01
We have investigated how the quality of stereoscopically measured topography degrades with varying illumination, in particular the ranges of incidence angles and illumination differences over which useful digital topographic models (DTMs) can be recovered. Our approach is to make high-fidelity simulated image pairs of known topography and compare DTMs from stereoanalysis of these images with the input data. Well-known rules of thumb for horizontal resolution (>3-5 pixels) and matching precision (~0.2-0.3 pixels) are generally confirmed, but the best achievable resolution at high incidence angles is ~15 pixels, probably as a result of smoothing internal to the matching algorithm. Single-pass stereo imaging of Europa is likely to yield DTMs of consistent (optimal) quality for all incidence angles ≤85°, and certainly for incidence angles between 40° and 85°. Simulations with pairs of images in which the illumination is not consistent support the utility of shadow tip distance (STD) as a measure of illumination difference, but also suggest new and simpler criteria for evaluating the suitability of stereopairs based on illumination geometry. Our study was motivated by the needs of a mission to Europa, but the approach and (to first order) the results described here are relevant to a wide range of planetary investigations.
Plane wave analysis of coherent holographic image reconstruction by phase transfer (CHIRPT).
Field, Jeffrey J; Winters, David G; Bartels, Randy A
2015-11-01
Fluorescent imaging plays a critical role in a myriad of scientific endeavors, particularly in the biological sciences. Three-dimensional imaging of fluorescent intensity often requires serial data acquisition, that is, voxel-by-voxel collection of fluorescent light emitted throughout the specimen with a nonimaging single-element detector. While nonimaging fluorescence detection offers some measure of scattering robustness, the rate at which dynamic specimens can be imaged is severely limited. Other fluorescent imaging techniques utilize imaging detection to enhance collection rates. A notable example is light-sheet fluorescence microscopy, also known as selective-plane illumination microscopy, which illuminates a large region within the specimen and collects emitted fluorescent light at an angle either perpendicular or oblique to the illumination light sheet. Unfortunately, scattering of the emitted fluorescent light can cause blurring of the collected images in highly turbid biological media. We recently introduced an imaging technique called coherent holographic image reconstruction by phase transfer (CHIRPT) that combines light-sheet-like illumination with nonimaging fluorescent light detection. By combining the speed of light-sheet illumination with the scattering robustness of nonimaging detection, CHIRPT is poised to have a dramatic impact on biological imaging, particularly for in vivo preparations. Here we present the mathematical formalism for CHIRPT imaging under spatially coherent illumination and present experimental data that verifies the theoretical model.
Deep level defects in dilute GaAsBi alloys grown under intense UV illumination
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mooney, P. M.; Tarun, Marianne; Beaton, D. A.
2016-07-21
Dilute GaAs1-xBix alloys exhibiting narrow band edge photoluminescence (PL) were recently grown by molecular beam epitaxy (MBE) with the growth surface illuminated by intense UV radiation. To investigate whether the improved optical quality of these films results from a reduction in the concentration of deep level defects, p+/n and n+/p junction diodes were fabricated on both the illuminated and dark areas of several samples. Deep Level Transient Spectroscopy (DLTS) measurements show that the illuminated and dark areas of both the n- and p-type GaAs1-xBix epi-layers have similar concentrations of near mid-gap electron and hole traps, in the 1015 cm-3 range.more » Thus the improved PL spectra cannot be explained by a reduction in non-radiative recombination at deep level defects. We note that carrier freeze-out above 35 K is significantly reduced in the illuminated areas of the p-type GaAs1-xBix layers compared to the dark areas, allowing the first DLTS measurements of defect energy levels close to the valence band edge. These defect levels may account for differences in the PL spectra from the illuminated and dark areas of un-doped layers with a similar Bi fraction.« less
Enhancing the isotropy of lateral resolution in coherent structured illumination microscopy
Park, Joo Hyun; Lee, Jae Yong; Lee, Eun Seong
2014-01-01
We present a method to improve the isotropy of spatial resolution in a structured illumination microscopy (SIM) implemented for imaging non-fluorescent samples. To alleviate the problem of anisotropic resolution involved with the previous scheme of coherent SIM that employs the two orthogonal standing-wave illumination, referred to as the orthogonal SIM, we introduce a hexagonal-lattice illumination that incorporates three standing-wave fields simultaneously superimposed at the orientations equally divided in the lateral plane. A theoretical formulation is worked out rigorously for the coherent image formation with such a simultaneous multiple-beam illumination and an explicit Fourier-domain framework is derived for reconstructing an image with enhanced resolution. Using a computer-synthesized resolution target as a 2D coherent sample, we perform numerical simulations to examine the imaging characteristics of our three-angle SIM compared with the orthogonal SIM. The investigation on the 2D resolving power with the various test patterns of different periods and orientations reveal that the orientation-dependent undulation of lateral resolution can be reduced from 27% to 8% by using the three-angle SIM while the best resolution (0.54 times the resolution limit of conventional coherent imaging) in the directions of structured illumination is slightly deteriorated by 4.6% from that of the orthogonal SIM. PMID:24940548
Use of a multiseparation fiber optic probe for the optical diagnosis of breast cancer.
Zhu, Changfang; Palmer, Gregory M; Breslin, Tara M; Xu, Fushen; Ramanujam, Nirmala
2005-01-01
We explore the effects of the illumination and collection geometry on optical spectroscopic diagnosis of breast cancer. Fluorescence and diffuse reflectance spectroscopy in the UV-visible spectral range are made with a multiseparation probe at three illumination-collection separations of 735, 980, and 1225 microm, respectively, from 13 malignant and 34 nonmalignant breast tissues. Statistical analysis is carried out on two types of data inputs: (1) the fluorescence and diffuse reflectance spectra recorded at each of the three illumination-collection separations and (2) the integrated fluorescence (at each excitation wavelength) or diffuse reflectance over the entire spectrum at all three illumination-collection separations. The results show that using the integrated fluorescence intensities recorded at a single excitation wavelength at all three illumination-collection separations can discriminate malignant from nonmalignant breast tissues with similar classification accuracy to that using spectral data measured at several excitation wavelengths with a single illumination-collection separation. These findings have significant implications with respect to the design of an optical system for breast cancer diagnosis. Examining the intensity attenuation at a single wavelength rather than spectral intensities at multiple wavelengths can significantly reduce the measurement and data processing time in a clinical setting as well as the cost and complexity of the optical system. Copyright 2005 Society of Photo-Optical Instrumentation Engineers.
NASA Astrophysics Data System (ADS)
Mehta, Shalin B.; Sheppard, Colin J. R.
2010-05-01
Various methods that use large illumination aperture (i.e. partially coherent illumination) have been developed for making transparent (i.e. phase) specimens visible. These methods were developed to provide qualitative contrast rather than quantitative measurement-coherent illumination has been relied upon for quantitative phase analysis. Partially coherent illumination has some important advantages over coherent illumination and can be used for measurement of the specimen's phase distribution. However, quantitative analysis and image computation in partially coherent systems have not been explored fully due to the lack of a general, physically insightful and computationally efficient model of image formation. We have developed a phase-space model that satisfies these requirements. In this paper, we employ this model (called the phase-space imager) to elucidate five different partially coherent systems mentioned in the title. We compute images of an optical fiber under these systems and verify some of them with experimental images. These results and simulated images of a general phase profile are used to compare the contrast and the resolution of the imaging systems. We show that, for quantitative phase imaging of a thin specimen with matched illumination, differential phase contrast offers linear transfer of specimen information to the image. We also show that the edge enhancement properties of spiral phase contrast are compromised significantly as the coherence of illumination is reduced. The results demonstrate that the phase-space imager model provides a useful framework for analysis, calibration, and design of partially coherent imaging methods.
Evaluation of illumination system uniformity for wide-field biomedical hyperspectral imaging
NASA Astrophysics Data System (ADS)
Sawyer, Travis W.; Siri Luthman, A.; E Bohndiek, Sarah
2017-04-01
Hyperspectral imaging (HSI) systems collect both spatial (morphological) and spectral (chemical) information from a sample. HSI can provide sensitive analysis for biological and medical applications, for example, simultaneously measuring reflectance and fluorescence properties of a tissue, which together with structural information could improve early cancer detection and tumour characterisation. Illumination uniformity is a critical pre-condition for quantitative data extraction from an HSI system. Non-uniformity can cause glare, specular reflection and unwanted shading, which negatively impact statistical analysis procedures used to extract abundance of different chemical species. Here, we model and evaluate several illumination systems frequently used in wide-field biomedical imaging to test their potential for HSI. We use the software LightTools and FRED. The analysed systems include: a fibre ring light; a light emitting diode (LED) ring; and a diffuse scattering dome. Each system is characterised for spectral, spatial, and angular uniformity, as well as transfer efficiency. Furthermore, an approach to measure uniformity using the Kullback-Leibler divergence (KLD) is introduced. The KLD is generalisable to arbitrary illumination shapes, making it an attractive approach for characterising illumination distributions. Although the systems are quite comparable in their spatial and spectral uniformity, the most uniform angular distribution is achieved using a diffuse scattering dome, yielding a contrast of 0.503 and average deviation of 0.303 over a ±60° field of view with a 3.9% model error in the angular domain. Our results suggest that conventional illumination sources can be applied in HSI, but in the case of low light levels, bespoke illumination sources may offer improved performance.
Pupillary response to direct and consensual chromatic light stimuli.
Traustason, Sindri; Brondsted, Adam Elias; Sander, Birgit; Lund-Andersen, Henrik
2016-02-01
To assess whether the direct and consensual postillumination (ipRGC-driven) pupil light responses to chromatic light stimuli are equal in healthy subjects. Pupil responses in healthy volunteers were recorded using a prototype binocular chromatic pupillometer (IdeaMedical, Copenhagen), which is capable of both direct and consensual pupillometry measurements. The device uses a pair of dual monochromatic narrow bandwidth LED light sources, red (660 nm) and blue (470 nm). Pupil light responses were recorded with infrared video cameras and analysed using custom-made circuitry and software. Subjects were randomized to receive light stimuli at either the right or left eye after 5 min of dark adaptation. Pupil light responses were recorded in both eyes for 10 seconds before illumination, during illumination and 50 seconds after illumination with red and blue light. Three variables were defined for the recorded pupil responses: the maximal constriction amplitude (CAmax ), the pupil response during illumination and postillumination pupil response (PIPR). No difference was found in the pupil response to blue light. With red light, the pupil response during illumination was slightly larger during consensual illumination compared to direct illumination (0.54 and 0.52, respectively, p = 0.027, paired Wilcoxon's test, n = 12), while no differences were found for CAmax or the PIPR. No difference was found between direct and consensual pupil response to either red or blue light in the postillumination period. Direct and consensual responses can readily be compared when examining the postillumination pupil response to blue light as estimation of photosensitive retinal ganglion cell activation. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Murphy, Michael K; Volsky, Peter G; Darrow, David H
2015-11-01
To test the hypothesis that a substantial proportion of laryngoscopes exhibit substandard illuminance by comparing laryngoscope illuminance in a tertiary-level medical center to established standards and identifying features associated with poor illuminance. Cross-sectional observational study. Academic tertiary care medical center (level 1 trauma center, specialty cardiac hospital, and general hospital). Laryngoscopes from main, cardiac, and outpatient operating rooms; emergency department; and code carts were tested using a standard technique. Illuminance (lux) was chosen as the outcome measure. Benchmarks were derived from the International Standards Organization and medical literature. Light types included incandescent bulb, light-emitting diode, and xenon. Personnel were surveyed regarding maintenance practices. Across all hospitals, 691 laryngoscopes were tested. Mean (SD) illuminance was 810 (700) lux for incandescent bulb-on-blade designs (n = 237), 1860 (1220) lux for incandescent bulb in-handle designs (n = 79), 4730 (3210) lux for LED (n = 354), and 28,800 (34,500) lux for xenon (n = 21). Seven percent of units failed to turn on (n = 45). Using an established threshold of 867 lux, 28% of devices (47% of incandescent, 12% of LED, and 10% of xenon) were substandard. All laryngoscopes were cleaned according to standard protocols following use; no preventive maintenance was reported. Twenty-eight percent of laryngoscopes in a tertiary care hospital exhibit substandard illuminance; these results corroborate the findings of our inaugural study on this subject. Consequently, our hospital is instituting changes to reduce the likelihood of substandard performance by laryngoscopes in circulation. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.
Color constancy in a naturalistic, goal-directed task
Radonjić, Ana; Cottaris, Nicolas P.; Brainard, David H.
2015-01-01
In daily life, we use color information to select objects that will best serve a particular goal (e.g., pick the best-tasting fruit or avoid spoiled food). This is challenging when judgments must be made across changes in illumination as the spectrum reflected from an object to the eye varies with the illumination. Color constancy mechanisms serve to partially stabilize object color appearance across illumination changes, but whether and to what degree constancy supports accurate cross-illumination object selection is not well understood. To get closer to understanding how constancy operates in real-life tasks, we developed a paradigm in which subjects engage in a goal-directed task for which color is instrumental. Specifically, in each trial, subjects re-created an arrangement of colored blocks (the model) across a change in illumination. By analyzing the re-creations, we were able to infer and quantify the degree of color constancy that mediated subjects' performance. In Experiments 1 and 2, we used our paradigm to characterize constancy for two different sets of block reflectances, two different illuminant changes, and two different groups of subjects. On average, constancy was good in our naturalistic task, but it varied considerably across subjects. In Experiment 3, we tested whether varying scene complexity and the validity of local contrast as a cue to the illumination change modulated constancy. Increasing complexity did not lead to improved constancy; silencing local contrast significantly reduced constancy. Our results establish a novel goal-directed task that enables us to approach color constancy as it emerges in real life. PMID:26381834
Rasta, Seyed Hossein; Partovi, Mahsa Eisazadeh; Seyedarabi, Hadi; Javadzadeh, Alireza
2015-01-01
To investigate the effect of preprocessing techniques including contrast enhancement and illumination correction on retinal image quality, a comparative study was carried out. We studied and implemented a few illumination correction and contrast enhancement techniques on color retinal images to find out the best technique for optimum image enhancement. To compare and choose the best illumination correction technique we analyzed the corrected red and green components of color retinal images statistically and visually. The two contrast enhancement techniques were analyzed using a vessel segmentation algorithm by calculating the sensitivity and specificity. The statistical evaluation of the illumination correction techniques were carried out by calculating the coefficients of variation. The dividing method using the median filter to estimate background illumination showed the lowest Coefficients of variations in the red component. The quotient and homomorphic filtering methods after the dividing method presented good results based on their low Coefficients of variations. The contrast limited adaptive histogram equalization increased the sensitivity of the vessel segmentation algorithm up to 5% in the same amount of accuracy. The contrast limited adaptive histogram equalization technique has a higher sensitivity than the polynomial transformation operator as a contrast enhancement technique for vessel segmentation. Three techniques including the dividing method using the median filter to estimate background, quotient based and homomorphic filtering were found as the effective illumination correction techniques based on a statistical evaluation. Applying the local contrast enhancement technique, such as CLAHE, for fundus images presented good potentials in enhancing the vasculature segmentation. PMID:25709940
Super-resolution chemical imaging with dynamic placement of plasmonic hotspots
NASA Astrophysics Data System (ADS)
Olson, Aeli P.; Ertsgaard, Christopher T.; McKoskey, Rachel M.; Rich, Isabel S.; Lindquist, Nathan C.
2015-08-01
We demonstrate dynamic placement of plasmonic "hotspots" for super-resolution chemical imaging via Surface Enhanced Raman Spectroscopy (SERS). A silver nanohole array surface was coated with biological samples and illuminated with a laser. Due to the large plasmonic field enhancements, blinking behavior of the SERS hotspots was observed and processed using a Stochastic Optical Reconstruction Microscopy (STORM) algorithm enabling localization to within 10 nm. However, illumination of the sample with a single static laser beam (i.e., a slightly defocused Gaussian beam) only produced SERS hotspots in fixed locations on the surface, leaving noticeable gaps in any final image. But, by using a spatial light modulator (SLM), the illumination profile of the beam could be altered, shifting any hotspots across the nanohole array surface in sub-wavelength steps. Therefore, by properly structuring an illuminating light field with the SLM, we show the possibility of positioning plasmonic hotspots over a metallic nanohole surface on-the-fly. Using this and our SERS-STORM imaging technique, we show potential for high-resolution chemical imaging without the noticeable gaps that were present with static laser illumination. Interestingly, even illuminating the surface with randomly shifting SLM phase profiles was sufficient to completely fill in a wide field of view for super-resolution SERS imaging of a single strand of 100-nm thick collagen protein fibrils. Images were then compared to those obtained with a scanning electron microscope (SEM). Additionally, we explored alternative methods of phase shifting other than holographic illumination through the SLM to create localization of hotspots necessary for SERS-STORM imaging.
NASA Astrophysics Data System (ADS)
Pravdivtsev, Andrey V.
2012-06-01
The article presents the approach to the design wide-angle optical systems with special illumination and instantaneous field of view (IFOV) requirements. The unevenness of illumination reduces the dynamic range of the system, which negatively influence on the system ability to perform their task. The result illumination on the detector depends among other factors from the IFOV changes. It is also necessary to consider IFOV in the synthesis of data processing algorithms, as it directly affects to the potential "signal/background" ratio for the case of statistically homogeneous backgrounds. A numerical-analytical approach that simplifies the design of wideangle optical systems with special illumination and IFOV requirements is presented. The solution can be used for optical systems which field of view greater than 180 degrees. Illumination calculation in optical CAD is based on computationally expensive tracing of large number of rays. The author proposes to use analytical expression for some characteristics which illumination depends on. The rest characteristic are determined numerically in calculation with less computationally expensive operands, the calculation performs not every optimization step. The results of analytical calculation inserts in the merit function of optical CAD optimizer. As a result we reduce the optimizer load, since using less computationally expensive operands. It allows reducing time and resources required to develop a system with the desired characteristics. The proposed approach simplifies the creation and understanding of the requirements for the quality of the optical system, reduces the time and resources required to develop an optical system, and allows creating more efficient EOS.
Fundus spectroscopy and studies in retinal oximetry using intravitreal illumination
NASA Astrophysics Data System (ADS)
Salyer, David Alan
This dissertation documents the development of a new illumination technique for use in the studies of retinal oximetry and fundus spectroscopy. Intravitreal illumination is a technique where the back of the eye is illuminated trans-sclerally using a scanning monochromator coupled into a fiber optic illuminator. Retinal oximetry is the process of measuring the oxygen saturation of blood contained in retinal vessels by quantitative measurement of the characteristic color shift seen as blood oxygen saturation changes from oxygenated blood (reddish) to deoxygenated blood (bluish). Retinal oximetry was first attempted in 1963 but due to a variety of problems with accuracy and difficulty of measurement, has not matured to the point of clinical acceptability or commercial viability. Accurate retinal oximetry relies in part on an adequate understanding of the spectral reflectance characteristics of the fundus. The use of intravitreal illumination allows new investigations into the spectral reflectance properties of the fundus. The results of much research in fundus reflectance and retinal oximetry is detailed in this document, providing new insight into both of these related fields of study. Intravitreal illumination has been used to study retinal vessel oximetry and fundus reflectometry resulting in several important findings that are presented in this document. Studies on enucleated swine eyes have provided new insight into the bidirectional reflectance distribution function of the fundus. Research on live swine has shown accurate measurement of retinal vessel oxygen saturation and provided the first in vivo spectral transmittance measurement of the sensory retina. A secondary discovery during this research suggests that vitrectomy alters the retinal vasculature, an finding that should spawn new research in its own right.
Dome flat-field system for 1.3-m Araki Telescope
NASA Astrophysics Data System (ADS)
Yoshikawa, Tomohiro; Ikeda, Yuji; Fujishiro, Naofumi; Ichizawa, Shunsuke; Arai, Akira; Isogai, Mizuki; Yonehara, Atsunori; Kawakita, Hideyo
2012-09-01
We report the system/optics design and performance of the dome flat-field system for the Araki Telescope, a 1.3- m optical/near-infrared telescope at Koyama Astronomical Observatory in Japan. A variety of instruments are attached to the telescope. The optical imager, which is intended to search for exoplanets, requires an illumination flatness within 1% on the focal plane over the 17-arcmin FOV. Illumination flatness at both the pupil plane and the focal plane of the telescope is essential for calibration of the transmittance of the optical system. We devised an optical design for the flat-field system that satisfies illumination flatness at both the focal and pupil planes using the non-sequential ray tracing software LightTools. We considered far-field illumination pattern of the lamps, scattering surface reflectance distribution of the screen, telescope structure, primary/secondary mirrors, and mirror baffles. We achieved a flat illumination distribution of 0.9% at the focal plane. The systems performance was tested by comparison with a cloud-flat frame, which was derived by imaging cloud cover illuminated by city lights. The calibration data for the dome flat-field system agree well with the cloud-flat frame within 1% for the g' and i' bands of the imager, but the r0 band data does not meet the requirement (less than or equal to 2). Moreover, various instruments require a focal plane illuminance ranging over three orders of magnitude. We used six high-power (60W) halogen lamps; the output power is remotely controlled by a thyristor-driven dimmer and a bypass circuit to an autotransformer.
NASA Astrophysics Data System (ADS)
Abbondanza, Claudio; Sarti, Pierguido
2010-08-01
This paper sets the rules for an optimal definition of precise signal path variation (SPV) models, revising and highlighting the deficiencies in the calculations adopted in previous studies and improving the computational approach. Hence, the linear coefficients that define the SPV model are rigorously determined. The equations that are presented depend on the dimensions and the focal lengths of the telescopes as well as on the feed illumination taper. They hold for any primary focus or Cassegrainian very long baseline interferometry (VLBI) telescope. Earlier investigations usually determined the SPV models assuming a uniform illumination of the telescope mirrors. We prove this hypothesis to be over-simplistic by comparing results derived adopting (a) uniform, (b) Gaussian and (c) binomial illumination functions. Numerical computations are developed for AZ-EL mount, 32 m Medicina and Noto (Italy) VLBI telescopes, these latter being the only telescopes which possess thorough information on gravity-dependent deformation patterns. Particularly, assuming a Gaussian illumination function, the SPV in primary focus over the elevation range [0°, 90°] is 10.1 and 7.2 mm, for Medicina and Noto, respectively. With uniform illumination function the maximal path variation for Medicina is 17.6 and 12.7 mm for Noto, thus highlighting the strong dependency on the choice of the illumination function. According to our findings, a revised SPV model is released for Medicina and a model for Noto is presented here for the first time. Currently, no other VLBI telescope possesses SPV models capable of correcting gravity-dependent observation biases.
Mental workload associated with operating an agricultural sprayer: an empirical approach.
Dey, A K; Mann, D D
2011-04-01
Agricultural spraying involves two major tasks: guiding a sprayer in response to a GPS navigation device, and simultaneous monitoring of rear-attached booms under various illumination and terrain difficulty levels. The aim of the present study was to investigate the effect of illumination, task difficulty, and task level on the mental workload of an individual operating an agricultural sprayer in response to a commercial GPS lightbar, and to explore the sensitivity of the NASA-TLX and SSWAT subjective rating scales in discriminating the subjective experienced workload under various task, illumination, and difficulty levels. Mental workload was measured using performance measures (lateral root mean square error and reaction time), physiological measures (0.1 Hz power of HRV, latency of the P300 component of event-related potential, and eye-glance behavior), and two subjective rating scales (NASA-TLX and SSWAT). Sixteen male university students participated in this experiment, and a fixed-base high-fidelity agricultural tractor simulator was used to create a simulated spraying task. All performance measures, the P300 latency, and subjective rating scales showed a common trend that mental workload increased with the change in illumination from day to night, with task difficulty from low to high, and with task type from single to dual. The 0.1 Hz power of HRV contradicted the performance measures. Eye-glance data showed that under night illumination, participants spent more time looking at the lightbar for guidance information. A similar trend was observed with the change in task type from single to dual. Both subjective rating scales showed a common trend of increasing mental workload with the change in illumination, difficulty, and task levels. However, the SSWAT scale was more sensitive than the NASA-TLX scale. With the change in illumination, difficulty, and task levels, participants spent more mental resources to meet the increased task demand; hence, the illumination, task difficulty, and task level affected the mental workload of an agricultural sprayer operator operating a sprayer in response to a GPS lightbar.
Illumination Conditions of the Lunar Polar Regions Using LOLA Topography
NASA Technical Reports Server (NTRS)
Mazarico, E.; Neumann, G. A.; Smith, D. E.; Zuber, M. T.; Torrence, M. H.
2011-01-01
We use high-resolution altimetry data obtained by the Lunar Orbiter Laser Altimeter instrument onboard the Lunar Reconnaissance Orbiter to characterize present illumination conditions in the polar regions of the Moon. Compared to previous studies, both the spatial and temporal extent of the simulations are increased significantly, as well as the coverage (fill ratio) of the topographic maps used, thanks to the 28 Hz firing rate of the five-beam instrument. We determine the horizon elevation in a number of directions based on 240 m-resolution polar digital elevation models reaching down to 75 latitude. The illumination of both polar regions extending to 80 can be calculated for any geometry from those horizon longitudinal profiles. We validated our modeling with recent Lunar Reconnaissance Orbiter Wide-Angle Camera images. We assessed the extent of permanently shadowed regions (PSRs, defined as areas that never receive direct solar illumination), and obtained total areas generally larger than previous studies (12,866 and 16,055 km2, in the north and south respectively). We extended our direct illumination model to account for singly-scattered light, and found that every PSR does receive some amount of scattered light during the year. We conducted simulations over long periods (several 18.6-years lunar precession cycles) with a high temporal resolution (6 h), and identified the most illuminated locations in the vicinity of both poles. Because of the importance of those sites for exploration and engineering considerations, we characterized their illumination more precisely over the near future. Every year, a location near the Shackleton crater rim in the south polar region is sunlit continuously for 240 days, and its longest continuous period in total darkness is about 1.5 days. For some locations small height gains ( 10 m) can dramatically improve their average illumination and reduce the night duration, rendering some of those particularly attractive energy-wise as possible sites for near-continuous sources of solar power.
NASA Astrophysics Data System (ADS)
Lesniak, Michael V.; Tregoning, Brett D.; Hitchens, Alexandra E.
2015-01-01
Our Sun outputs 3.85 x 1026 W of radiation, of which roughly 37% is in the visible band. It is directly responsible for nearly all natural illuminance experienced on Earth's surface, either in the form of direct/refracted sunlight or in reflected light bouncing off the surfaces and/or atmospheres of our Moon and the visible planets. Ground illuminance, defined as the amount of visible light intercepting a unit area of surface (from all incident angles), varies over 7 orders of magnitude from day to night. It is highly dependent on well-modeled factors such as the relative positions of the Sun, Earth, and Moon. It is also dependent on less predictable factors such as local atmospheric conditions and weather.Several models have been proposed to predict ground illuminance, including Brown (1952) and Shapiro (1982, 1987). The Brown model is a set of empirical data collected from observation points around the world that has been reduced to a smooth fit of illuminance against a single variable, solar altitude. It provides limited applicability to the Moon and for cloudy conditions via multiplicative reduction factors. The Shapiro model is a theoretical model that treats the atmosphere as a three layer system of light reflectance and transmittance. It has different sets of reflectance and transmittance coefficients for various cloud types.In this paper we compare the models' predictions to ground illuminance data from an observing run at the White Sands missile range (data was obtained from the United Kingdom's Meteorology Office). Continuous illuminance readings were recorded under various cloud conditions, during both daytime and nighttime hours. We find that under clear skies, the Shapiro model tends to better fit the observations during daytime hours with typical discrepancies under 10%. Under cloudy skies, both models tend to poorly predict ground illuminance. However, the Shapiro model, with typical average daytime discrepancies of 25% or less in many cases, performed somewhat better than the Brown model during daytime hours. During nighttime hours under cloudy skies, both models produced erratic results.
Dogramaci, Mahmut; Williams, Katie; Lee, Ed; Williamson, Tom H
2013-01-01
There is sudden and dramatic visual function deterioration in 1-10 % of eyes filled with silicone oil at the time of removal of silicon oil. Transmission of high-energy blue light is increased in eyes filled with silicone oil. We sought to identify if increased foveal light exposure is a potential factor in the pathophysiology of the visual loss at the time of removal of silicone oil. A graphic ray tracing computer program and laboratory models were used to determine the effect of the intraocular silicone oil bubble size on the foveal illuminance at the time of removal of silicone oil under direct microscope light. The graphic ray tracing computer program revealed a range of optical vignetting effects created by different sizes of silicone oil bubble within the vitreous cavity giving rise to an uneven macular illumination. The laboratory model was used to quantify the variation of illuminance at the foveal region with different sizes of silicone oil bubble with in the vitreous cavity at the time of removal of silicon oil under direct microscope light. To substantiate the hypothesis of the light toxicity during removal of silicone oil, The outcome of oil removal procedures performed under direct microscope illumination in compared to those performed under blocked illumination. The computer program showed that the optical vignetting effect at the macula was dependent on the size of the intraocular silicone oil bubble. The laboratory eye model showed that the foveal illuminance followed a bell-shaped curve with 70 % greater illuminance demonstrated at with 50-60 % silicone oil fill. The clinical data identified five eyes with unexplained vision loss out of 114 eyes that had the procedure performed under direct microscope illumination compared to none out of 78 eyes that had the procedure under blocked illumination. Foveal light exposure, and therefore the potential for phototoxicity, is transiently increased at the time of removal of silicone oil. This is due to uneven macular illumination resulting from the optical vignetting effect of different silicone oil bubble sizes. The increase in foveal light exposure may be significant when the procedure is performed under bright operating microscope light on already stressed photoreceptors of an eye filled with silicon oil. We advocate the use of precautions, such as central shadow filter on the operating microscope light source to reduce foveal light exposure and the risk of phototoxicity at the time of removal of silicone oil. The graphic ray tracing computer program used in this study shows promise in eye modeling for future studies.
Photo-oxidation of polymer-like amorphous hydrogenated carbon under visible light illumination
Baxamusa, Salmaan; Laurence, Ted; Worthington, Matthew; ...
2015-11-10
Amorphous hydrogenated carbon (a-C:H), a polymer-like network typically synthesized by plasma chemical vapor deposition, has long been understood to exhibit optical absorption of visible light (λ > 400 nm). In this report we explain that this absorption is accompanied by rapid photo-oxidation (within minutes) that behaves in most respects like classic polymer photo-oxidation with the exception that it occurs under visible light illumination rather than ultraviolet illumination.
Enhanced weak-signal sensitivity in two-photon microscopy by adaptive illumination.
Chu, Kengyeh K; Lim, Daryl; Mertz, Jerome
2007-10-01
We describe a technique to enhance both the weak-signal relative sensitivity and the dynamic range of a laser scanning optical microscope. The technique is based on maintaining a fixed detection power by fast feedback control of the illumination power, thereby transferring high measurement resolution to weak signals while virtually eliminating the possibility of image saturation. We analyze and demonstrate the benefits of adaptive illumination in two-photon fluorescence microscopy.
Laterally modulated excitation microscopy: improvement of resolution by using a diffraction grating
NASA Astrophysics Data System (ADS)
Heintzmann, Rainer; Cremer, Christoph G.
1999-01-01
High spatial frequencies in the illuminating light of microscopes lead to a shift of the object spatial frequencies detectable through the objective lens. If a suitable procedure is found for evaluation of the measured data, a microscopic image with a higher resolution than under flat illumination can be obtained. A simple method for generation of a laterally modulated illumination pattern is discussed here. A specially constructed diffraction grating was inserted in the illumination beam path at the conjugate object plane (position of the adjustable aperture) and projected through the objective into the object. Microscopic beads were imaged with this method and evaluated with an algorithm based on the structure of the Fourier space. The results indicate an improvement of resolution.
Geometry of illumination, luminance contrast, and gloss perception.
Leloup, Frédéric B; Pointer, Michael R; Dutré, Philip; Hanselaer, Peter
2010-09-01
The influence of both the geometry of illumination and luminance contrast on gloss perception has been examined using the method of paired comparison. Six achromatic glass samples having different lightness were illuminated by two light sources. Only one of these light sources was visible in reflection by the observer. By separate adjustment of the intensity of both light sources, the luminance of both the reflected image and the adjacent off-specular surroundings could be individually varied. It was found that visual gloss appraisal did not correlate with instrumentally measured specular gloss; however, psychometric contrast seemed to be a much better correlate. It has become clear that not only the sample surface characteristics determine gloss perception: the illumination geometry could be an even more important factor.
Reflector system for a lighting fixture
Siminovitch, M.J.; Page, E.; Gould, C.T.
1998-09-08
Disclosed herein is a reflector system for a lighting fixture having a illumination source surrounded by an envelope. The reflector system includes a first reflector surrounding the illumination source. The reflector system also includes a second reflector which is non-contiguous with the first reflector and which surrounds the illumination source. The illumination source creates light rays which are reflected by the first and second reflectors. The first reflector directs light rays toward the center line of the fixture. However, the reflected rays despite being so reflected do not substantially intersect the envelope. The reflected light rays from the second reflector being directed so that they diverge from the center line of the fixture avoiding intersection with the semi-transparent envelope. 5 figs.
Sabatini, Jesse J; Nagori, Amita V; Chen, Gary; Chu, Phillip; Damavarapu, Reddy; Klapötke, Thomas M
2012-01-09
The full-up prototype testing of perchlorate-free, hand-held, signal illuminants for the US Army's M126A1 red star parachute hand-held signal is described. Compared to the perchlorate-containing control, the disclosed illuminants yielded excellent stabilities toward various ignition stimuli while offering superior pyrotechnic performance. Militarily, the illuminants provided further evidence that development of smaller hand-held signal items in an environmentally conscious way is a realistic and obtainable goal. The results are also important from the perspective of civilian fireworks, as the development of brighter, longer-burning, and environmentally compatible red-light-emitting pyrotechnics is now possible. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A device for multimodal imaging of skin
NASA Astrophysics Data System (ADS)
Spigulis, Janis; Garancis, Valerijs; Rubins, Uldis; Zaharans, Eriks; Zaharans, Janis; Elste, Liene
2013-03-01
A compact prototype device for diagnostic imaging of skin has been developed and tested. Polarized LED light at several spectral regions is used for illumination, and round skin spot of diameter 30mm is imaged by a CMOS sensor via crossoriented polarizing filter. Four consecutive imaging series are performed: (1) RGB image at white LED illumination for revealing subcutaneous structures; (2) four spectral images at narrowband LED illumination (450nm, 540nm, 660nm, 940nm) for mapping of the main skin chromophores; (3) video-imaging under green LED illumination for mapping of skin blood perfusion; (4) autofluorescence video-imaging under UV (365nm) LED irradiation for mapping of the skin fluorophores. Design details of the device as well as preliminary results of clinical tests are presented.
Yaqoob, Zahid; Choi, Wonshik; Oh, Seungeun; Lue, Niyom; Park, Yongkeun; Fang-Yen, Christopher; Dasari, Ramachandra R.; Badizadegan, Kamran; Feld, Michael S.
2010-01-01
We report a quantitative phase microscope based on spectral domain optical coherence tomography and line-field illumination. The line illumination allows self phase-referencing method to reject common-mode phase noise. The quantitative phase microscope also features a separate reference arm, permitting the use of high numerical aperture (NA > 1) microscope objectives for high resolution phase measurement at multiple points along the line of illumination. We demonstrate that the path-length sensitivity of the instrument can be as good as 41 pm/Hz, which makes it suitable for nanometer scale study of cell motility. We present the detection of natural motions of cell surface and two-dimensional surface profiling of a HeLa cell. PMID:19550464
Vicinal light inspection of translucent materials
Burns, Geroge R [Albuquerque, NM; Yang, Pin [Albuquerque, NM
2010-01-19
The present invention includes methods and apparatus for inspecting vicinally illuminated non-patterned areas of translucent materials. An initial image of the material is received. A second image is received following a relative translation between the material being inspected and a device generating the images. Each vicinally illuminated image includes a portion having optimal illumination, that can be extracted and stored in a composite image of the non-patterned area. The composite image includes aligned portions of the extracted image portions, and provides a composite having optimal illumination over a non-patterned area of the material to be inspected. The composite image can be processed by enhancement and object detection algorithms, to determine the presence of, and characterize any inhomogeneities present in the material.
NASA Astrophysics Data System (ADS)
Chen, Youhua; Cao, Ruizhi; Liu, Wenjie; Zhu, Dazhao; Zhang, Zhiming; Kuang, Cuifang; Liu, Xu
2018-04-01
We present an alternative approach to realize structured illumination microscopy (SIM), which is capable for live cell imaging. The prototype utilizes two sets of scanning galvo mirrors, a polarization converter and a piezo-platform to generate a fast shifted, s-polarization interfered and periodic variable illumination patterns. By changing the angle of the scanning galvanometer, we can change the position of the spots at the pupil plane of the objective lens arbitrarily, making it easy to switch between widefield and total internal reflection fluorescent-SIM mode and adapting the penetration depth in the sample. Also, a twofold resolution improvement is achieved in our experiments. The prototype offers more flexibility of pattern period and illumination orientation changing than previous systems.
Many-junction photovoltaic device performance under non-uniform high-concentration illumination
NASA Astrophysics Data System (ADS)
Valdivia, Christopher E.; Wilkins, Matthew M.; Chahal, Sanmeet S.; Proulx, Francine; Provost, Philippe-Olivier; Masson, Denis P.; Fafard, Simon; Hinzer, Karin
2017-09-01
A parameterized 3D distributed circuit model was developed to calculate the performance of III-V solar cells and photonic power converters (PPC) with a variable number of epitaxial vertically-stacked pn junctions. PPC devices are designed with many pn junctions to realize higher voltages and to operate under non-uniform illumination profiles from a laser or LED. Performance impacts of non-uniform illumination were greatly reduced with increasing number of junctions, with simulations comparing PPC devices with 3 to 20 junctions. Experimental results using Azastra Opto's 12- and 20-junction PPC illuminated by an 845 nm diode laser show high performance even with a small gap between the PPC and optical fiber output, until the local tunnel junction limit is reached.
3D topography of biologic tissue by multiview imaging and structured light illumination
NASA Astrophysics Data System (ADS)
Liu, Peng; Zhang, Shiwu; Xu, Ronald
2014-02-01
Obtaining three-dimensional (3D) information of biologic tissue is important in many medical applications. This paper presents two methods for reconstructing 3D topography of biologic tissue: multiview imaging and structured light illumination. For each method, the working principle is introduced, followed by experimental validation on a diabetic foot model. To compare the performance characteristics of these two imaging methods, a coordinate measuring machine (CMM) is used as a standard control. The wound surface topography of the diabetic foot model is measured by multiview imaging and structured light illumination methods respectively and compared with the CMM measurements. The comparison results show that the structured light illumination method is a promising technique for 3D topographic imaging of biologic tissue.
Anti-glare LED lamps with adjustable illumination light field.
Chen, Yung-Sheng; Lin, Chung-Yi; Yeh, Chun-Ming; Kuo, Chie-Tong; Hsu, Chih-Wei; Wang, Hsiang-Chen
2014-03-10
We introduce a type of LED light-gauge steel frame lamp with an adjustable illumination light field that does not require a diffusion plate. Base on the Monte Carlo ray tracing method, this lamp has a good glare rating (GR) of 17.5 at 3050 lm. Compared with the traditional LED light-gauge steel frame lamp (without diffusion plate), the new type has low GR. The adjustability of the illumination light field could improve the zebra effect caused by the inadequate illumination light field of the lamp. Meanwhile, we adopt the retinal image analysis to discuss the influence of GR on vision. High GR could reflect stray light on the retinal image, which will reduce vision clarity and hasten the feeling of eye fatigue.
Pavilack, M A; Brod, R D
2001-02-01
To determine the site of focal illumination on the retina of phakic human cadaver eyes from an operating microscope positioned for temporal approach eye surgery. Experimental study. A Zeiss OPMI-6SFR operating microscope (Zeiss Humphrey Systems, Dublin, CA) was positioned over two phakic human cadaver eyes to measure the site of the focal illumination on the retina by directly observing the illumination on the posterior scleral surface of the globe. External localization of the foveola was made by direct observation using scleral indentation and indirect ophthalmoscopy. Various combinations of microscope angulation and field of view were analyzed. Distance of focal illumination from the operating room microscope relative to the foveola was measured. The diameter of the "hot spot" of focal illumination on the retina was 4.0 mm. With the eye positioned straight ahead and the level operating room microscope positioned for temporal approach eye surgery, the center of retinal illumination was 0.9 and 1.4 mm nasal relative to the foveola when the microscope field of view was centered over the cornea and temporal limbus, respectively. With the microscope angled 5, 10, 15, and 20 degrees temporally (oculars tilted toward surgeon), the center of the illumination was displaced nasal to the foveola by 1.1, 1.5, 3.8, and 5.1 mm, respectively, when the field of view was centered over the cornea and 1.5, 2.6, 4.7, and 6.0 mm, respectively, nasal to the foveola when centered over the temporal limbus. Retinal illumination from an operating microscope positioned for temporal approach eye surgery has the potential for light-induced injury to the fovea. Angulation of the operating microscope by up to 10 degrees temporally when the microscope field of view was centered over the cornea and up to 5 degrees temporally when centered over the temporal limbus was not adequate to displace the focal illumination off the foveola when the eye was in the straight-ahead position. Tilting the operating microscope 15 degrees or more temporally when centered on the pupil and 10 degrees or more when centered over the temporal limbus should safely displace the retinal light exposure away from the fovea during temporal approach surgery. Suggestions for reducing the risk of iatrogenic phototoxicity are reviewed.
Super-resolution photoacoustic microscopy using joint sparsity
NASA Astrophysics Data System (ADS)
Burgholzer, P.; Haltmeier, M.; Berer, T.; Leiss-Holzinger, E.; Murray, T. W.
2017-07-01
We present an imaging method that uses the random optical speckle patterns that naturally emerge as light propagates through strongly scattering media as a structured illumination source for photoacoustic imaging. Our approach, termed blind structured illumination photoacoustic microscopy (BSIPAM), was inspired by recent work in fluorescence microscopy where super-resolution imaging was demonstrated using multiple unknown speckle illumination patterns. We extend this concept to the multiple scattering domain using photoacoustics (PA), with the speckle pattern serving to generate ultrasound. The optical speckle pattern that emerges as light propagates through diffuse media provides structured illumination to an object placed behind a scattering wall. The photoacoustic signal produced by such illumination is detected using a focused ultrasound transducer. We demonstrate through both simulation and experiment, that by acquiring multiple photoacoustic images, each produced by a different random and unknown speckle pattern, an image of an absorbing object can be reconstructed with a spatial resolution far exceeding that of the ultrasound transducer. We experimentally and numerically demonstrate a gain in resolution of more than a factor of two by using multiple speckle illuminations. The variations in the photoacoustic signals generated with random speckle patterns are utilized in BSIPAM using a novel reconstruction algorithm. Exploiting joint sparsity, this algorithm is capable of reconstructing the absorbing structure from measured PA signals with a resolution close to the speckle size. Another way to excite random excitation for photoacoustic imaging are small absorbing particles, including contrast agents, which flow through small vessels. For such a set-up, the joint-sparsity is generated by the fact that all the particles move in the same vessels. Structured illumination in that case is not necessary.
Optical mass gauge sensor having an energy per unit area of illumination detection
NASA Technical Reports Server (NTRS)
Justak, John F. (Inventor)
2000-01-01
An optical mass gauge sensor is disclosed comprising a vessel having an interior surface which reflects radiant energy at a wavelength at least partially absorbed by a fluid contained within the vessel, an illuminating device for introducing radiant energy at such wavelength into the vessel interior, and, a detector for measuring the energy per unit area of illumination within the vessel created by the radiant energy which is not absorbed by the fluid.
UV Light Illumination Can Improve the Sensing Properties of LaFeO₃ to Acetone Vapor.
Zhang, Heng; Qin, Hongwei; Gao, Chengyong; Zhou, Guangjun; Chen, Yanping; Hu, Jifan
2018-06-21
The synthesized LaFeO₃ nanocrystalline sensor powders show positive response to sensing acetone vapor at 200 °C. The responses to acetone vapor (at 0.5, 1, 2, 5, 10 ppm) are 1.18, 1.22, 1.89, 3.2 and 7.83. To make the sensor operate at a lower optimum temperature, UV light illumination 365 nm is performed. Response of the sensor has a larger improvement under 365 nm UV light illumination than without it. The responses to acetone vapor (at 0.5, 1, 2, 5, 10 ppm) are 1.37, 1.85, 3.16, 8.32 and 14.1. Furthermore, the optimum operating temperature is reduced to 170 °C. As the relative humidity increases, the resistance and sensitivity of sensor are reduced. The sensor shows good selectivity toward acetone when compared with other gases. Since the detection of ultralow concentrations of acetone vapor is possible, the sensor can be used to preliminarily judge diabetes in the general public, as a high concentration of acetone is exhaled in breath of diabetic patients. The sensor shows a good stability, which is further enhanced under UV light illumination. The sensor shows better stability when under 365 nm UV light illumination. Whether under light illumination or not. The LaFeO₃ material shows good performance as a sensor when exposed to acetone vapor.
NASA Astrophysics Data System (ADS)
Choi, Kyungah; Suk, Hyeon-Jeong
2015-01-01
The purpose of this study is to investigate the differences in the psychophysical judgment of mobile display color appearances between Europeans and Asians. A total of 50 participants, comprising 20 Europeans (9 French, 6 Swedish, 3 Norwegians, and 2 Germans) and 30 Asians (30 Koreans) participated in this experiment. A total of 18 display stimuli with different correlated color temperatures were presented, varying from 2,470 to 18,330 K. Each stimulus was viewed under 11 illuminants ranging from 2,530 to 19,760 K, while their illuminance was consistent around 500 lux. The subjects were asked to assess the optimal level of the display stimuli under different illuminants. In general, confirming the previous studies on color reproduction, we found a positive correlation in the correlated color temperatures between the illuminants and optimal displays. However, Europeans preferred a lower color temperature compared to Asians along the entire range of the illuminants. Two regression equations were derived to predict the optimal display color temperature (y) under varying illuminants (x) as follows: y = α + β*log(x), where α = -8770.37 and β = 4279.29 for European (R2 = 0.95, p < .05), and α = -16076.35 and β = 6388.41 for Asian (R2 = 0.85, p < .05). The findings provide the theoretical basis from which manufacturers can take a cultural-sensitive approach to enhancing their products' appeal in the global markets.
Accommodating multiple illumination sources in an imaging colorimetry environment
NASA Astrophysics Data System (ADS)
Tobin, Kenneth W., Jr.; Goddard, James S., Jr.; Hunt, Martin A.; Hylton, Kathy W.; Karnowski, Thomas P.; Simpson, Marc L.; Richards, Roger K.; Treece, Dale A.
2000-03-01
Researchers at the Oak Ridge National Laboratory have been developing a method for measuring color quality in textile products using a tri-stimulus color camera system. Initial results of the Imaging Tristimulus Colorimeter (ITC) were reported during 1999. These results showed that the projection onto convex sets (POCS) approach to color estimation could be applied to complex printed patterns on textile products with high accuracy and repeatability. Image-based color sensors used for on-line measurement are not colorimetric by nature and require a non-linear transformation of the component colors based on the spectral properties of the incident illumination, imaging sensor, and the actual textile color. Our earlier work reports these results for a broad-band, smoothly varying D65 standard illuminant. To move the measurement to the on-line environment with continuously manufactured textile webs, the illumination source becomes problematic. The spectral content of these light sources varies substantially from the D65 standard illuminant and can greatly impact the measurement performance of the POCS system. Although absolute color measurements are difficult to make under different illumination, referential measurements to monitor color drift provide a useful indication of product quality. Modifications to the ITC system have been implemented to enable the study of different light sources. These results and the subsequent analysis of relative color measurements will be reported for textile products.
Aoki, Hisae; Yamashita, Hiromasa; Mori, Toshiyuki; Fukuyo, Tsuneo; Chiba, Toshio
2014-11-01
We developed a new ultrahigh-sensitive CMOS camera using a specific sensor that has a wide range of spectral sensitivity characteristics. The objective of this study is to present our updated endoscopic technology that has successfully integrated two innovative functions; ultrasensitive imaging as well as advanced fluorescent viewing. Two different experiments were conducted. One was carried out to evaluate the function of the ultrahigh-sensitive camera. The other was to test the availability of the newly developed sensor and its performance as a fluorescence endoscope. In both studies, the distance from the endoscopic tip to the target was varied and those endoscopic images in each setting were taken for further comparison. In the first experiment, the 3-CCD camera failed to display the clear images under low illumination, and the target was hardly seen. In contrast, the CMOS camera was able to display the targets regardless of the camera-target distance under low illumination. Under high illumination, imaging quality given by both cameras was quite alike. In the second experiment as a fluorescence endoscope, the CMOS camera was capable of clearly showing the fluorescent-activated organs. The ultrahigh sensitivity CMOS HD endoscopic camera is expected to provide us with clear images under low illumination in addition to the fluorescent images under high illumination in the field of laparoscopic surgery.
Structuring Light to Manipulate Multipolar Resonances for Metamaterial Applications
NASA Astrophysics Data System (ADS)
Das, Tanya
Multipolar electromagnetic phenomena in sub-wavelength resonators are at the heart of metamaterial science and technology. Typically, researchers engineer multipolar light-matter interactions by modifying the size, shape, and composition of the resonators. Here, we instead engineer multipolar interactions by modifying properties of the incident radiation. In this dissertation, we propose a new framework for determining the scattering response of resonators based on properties of the local excitation field. First, we derive an analytical theory to determine the scattering response of spherical nanoparticles under any type of illumination. Using this theory, we demonstrate the ability to drastically manipulate the scattering properties of a spherical nanoparticle by varying the illumination and demonstrate excitation of a longitudinal quadrupole mode that cannot be accessed with conventional illumination. Next, we investigate the response of dielectric dimer structures illuminated by cylindrical vector beams. Using finite-difference time-domain simulations, we demonstrate significant modification of the scattering spectra of dimer antennas and reveal how the illumination condition gives rise to these spectra through manipulation of electric and magnetic mode hybridization. Finally, we present a simple and efficient numerical simulation based on local field principles for extracting the multipolar response of any resonator under illumination by structured light. This dissertation enhances the understanding of fundamental light-matter interactions in metamaterials and lays the foundation for researchers to identify, quantify, and manipulate multipolar light-matter interactions through optical beam engineering.
Minimizing photodecomposition of flavin adenine dinucleotide fluorescence by the use of pulsed LEDs.
Rösner, J; Liotta, A; Angamo, E A; Spies, C; Heinemann, U; Kovács, R
2016-11-01
Dynamic alterations in flavin adenine dinucleotide (FAD) fluorescence permit insight into energy metabolism-dependent changes of intramitochondrial redox potential. Monitoring FAD fluorescence in living tissue is impeded by photobleaching, restricting the length of microfluorimetric recordings. In addition, photodecomposition of these essential electron carriers negatively interferes with energy metabolism and viability of the biological specimen. Taking advantage of pulsed LED illumination, here we determined the optimal excitation settings giving the largest fluorescence yield with the lowest photobleaching and interference with metabolism in hippocampal brain slices. The effects of FAD bleaching on energy metabolism and viability were studied by monitoring tissue pO 2 , field potentials and changes in extracellular potassium concentration ([K + ] o ). Photobleaching with continuous illumination consisted of an initial exponential decrease followed by a nearly linear decay. The exponential decay was significantly decelerated with pulsed illumination. Pulse length of 5 ms was sufficient to reach a fluorescence output comparable to continuous illumination, whereas further increasing duration increased photobleaching. Similarly, photobleaching increased with shortening of the interpulse interval. Photobleaching was partially reversible indicating the existence of a transient nonfluorescent flavin derivative. Pulsed illumination decreased FAD photodecomposition, improved slice viability and reproducibility of stimulus-induced FAD, field potential, [K + ] o and pO 2 changes as compared to continuous illumination. © 2016 The Authors Journal of Microscopy © 2016 Royal Microscopical Society.
Kothari, Mihir; Kothari, Kedar; Kadam, Sanjay; Mota, Poonam; Chipade, Snehal
2015-01-01
To report the "do it yourself" method of converting an existing wired-halogen indirect ophthalmoscope (IO) to a wireless-light emitting diode (LED) IO and report the preferences of the patients and the ophthalmologists. In this prospective observational study, a conventional IO was converted to wireless-LED IO using easily available, affordable electrical components. Conventional and the converted IO were then used to perform photo-stress test and take the feedback of subjects and the ophthalmologists regarding its handling and illumination characteristics. The cost of conversion to wireless-LED was 815/- rupees. Twenty-nine subjects, mean age 34.3 [formula in text] 10 years with normal eyes were recruited in the study. Between the two illumination systems, there was no statistical difference in the magnitude of the visual acuity loss and the time to recovery of acuity and the bleached vision on photo-stress test, although the visual recovery was clinically faster with LED illumination. The heat sensation was more with halogen illumination than the LED (P = 0.009). The ophthalmologists rated wireless-LED IO higher than wired-halogen IO on the handling, examination comfort, patient's visual comfort and quality of the image. Twenty-two (81%) ophthalmologists wanted to change over to wireless-LED IO. Converting to wireless-LED IO is easy, cost-effective and preferred over a wired-halogen indirect ophthalmoscope.
Dynamic Features for Iris Recognition.
da Costa, R M; Gonzaga, A
2012-08-01
The human eye is sensitive to visible light. Increasing illumination on the eye causes the pupil of the eye to contract, while decreasing illumination causes the pupil to dilate. Visible light causes specular reflections inside the iris ring. On the other hand, the human retina is less sensitive to near infra-red (NIR) radiation in the wavelength range from 800 nm to 1400 nm, but iris detail can still be imaged with NIR illumination. In order to measure the dynamic movement of the human pupil and iris while keeping the light-induced reflexes from affecting the quality of the digitalized image, this paper describes a device based on the consensual reflex. This biological phenomenon contracts and dilates the two pupils synchronously when illuminating one of the eyes by visible light. In this paper, we propose to capture images of the pupil of one eye using NIR illumination while illuminating the other eye using a visible-light pulse. This new approach extracts iris features called "dynamic features (DFs)." This innovative methodology proposes the extraction of information about the way the human eye reacts to light, and to use such information for biometric recognition purposes. The results demonstrate that these features are discriminating features, and, even using the Euclidean distance measure, an average accuracy of recognition of 99.1% was obtained. The proposed methodology has the potential to be "fraud-proof," because these DFs can only be extracted from living irises.
Smart Garment Fabrics to Enable Non-Contact Opto-Physiological Monitoring.
Iakovlev, Dmitry; Hu, Sijung; Hassan, Harnani; Dwyer, Vincent; Ashayer-Soltani, Roya; Hunt, Chris; Shen, Jinsong
2018-03-29
Imaging photoplethysmography (iPPG) is an emerging technology used to assess microcirculation and cardiovascular signs by collecting backscattered light from illuminated tissue using optical imaging sensors. The aim of this study was to study how effective smart garment fabrics could be capturing physiological signs in a non-contact mode. The present work demonstrates a feasible approach of, instead of using conventional high-power illumination sources, integrating a grid of surface-mounted light emitting diodes (LEDs) into cotton fabric to spotlight the region of interest (ROI). The green and the red LEDs (525 and 660 nm) placed on a small cotton substrate were used to locally illuminate palm skin in a dual-wavelength iPPG setup, where the backscattered light is transmitted to a remote image sensor through the garment fabric. The results show that the illuminations from both wavelength LEDs can be used to extract heart rate (HR) reaching an accuracy of 90% compared to a contact PPG probe. Stretching the fabric over the skin surface alters the morphology of iPPG signals, demonstrating a significantly higher pulsatile amplitude in both channels of green and red illuminations. The skin compression by the fabric could be potentially utilised to enhance the penetration of illumination into cutaneous microvascular beds. The outcome could lead a new avenue of non-contact opto-physiological monitoring and assessment with functional garment fabrics.
Soto, Juan M; Rodrigo, José A; Alieva, Tatiana
2018-01-01
Quantitative label-free imaging is an important tool for the study of living microorganisms that, during the last decade, has attracted wide attention from the optical community. Optical diffraction tomography (ODT) is probably the most relevant technique for quantitative label-free 3D imaging applied in wide-field microscopy in the visible range. The ODT is usually performed using spatially coherent light illumination and specially designed holographic microscopes. Nevertheless, the ODT is also compatible with partially coherent illumination and can be realized in conventional wide-field microscopes by applying refocusing techniques, as it has been recently demonstrated. Here, we compare these two ODT modalities, underlining their pros and cons and discussing the optical setups for their implementation. In particular, we pay special attention to a system that is compatible with a conventional wide-field microscope that can be used for both ODT modalities. It consists of two easily attachable modules: the first for sample illumination engineering based on digital light processing technology; the other for focus scanning by using an electrically driven tunable lens. This hardware allows for a programmable selection of the wavelength and the illumination design, and provides fast data acquisition as well. Its performance is experimentally demonstrated in the case of ODT with partially coherent illumination providing speckle-free 3D quantitative imaging.
[The H+/e- ratio in the photosynthetic electron transport chain].
Ivanov, B N; Shmeleva, V L; Ovchinnikova, V I
1983-06-01
The number of protons adsorbed by tylakoids during one electron passage along the photosynthetic electron transport chain (i.e. the H+/e- ratio) was measured in isolated pea chloroplasts upon continuous illumination. Methylviologen was used as electron acceptor on the reducing side of PS I. It was found that at pH 6.0 upon illumination with red light (lambda greater than 620 nm) at an intensity of 2 . 10(5) erg/cm2 . s ("intensive" light) the H+/e- ratio is equal to 3. Upon illumination of dark-adapted chloroplasts with a "weak" light (900 erg/cm2 . s) the H+/e- ratio is equal to 2. Upon illumination of the chloroplasts with a "weak" after "intensive" light the value of this ratio is close to 3. Azide when added to the reaction mixture may interfere with the accuracy of measurements of the value of the H+/e- ratio by affecting proton exchange. Based on the changes in the H+/e- ratio induced by illumination it was assumed that at saturating intensity of the illuminating light the electron transport chain passes into a so-called "light" state when the mechanisms of proton-electron coupling differing from those of rare electron transfer ("weak" light, flashes) are triggered on. At pH 6.0 the "light" state of the electron transport chain is maintained for some time in the dark.
29 CFR 1918.92 - Illumination.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Walking, working, and climbing areas. Walking, working, and climbing areas shall be illuminated. Unless... contact with drafts, running gear, and other moving equipment. (4) Portable cargo lights furnished by the...
The effect of background and illumination on color identification of real, 3D objects.
Allred, Sarah R; Olkkonen, Maria
2013-01-01
For the surface reflectance of an object to be a useful cue to object identity, judgments of its color should remain stable across changes in the object's environment. In 2D scenes, there is general consensus that color judgments are much more stable across illumination changes than background changes. Here we investigate whether these findings generalize to real 3D objects. Observers made color matches to cubes as we independently varied both the illumination impinging on the cube and the 3D background of the cube. As in 2D scenes, we found relatively high but imperfect stability of color judgments under an illuminant shift. In contrast to 2D scenes, we found that background had little effect on average color judgments. In addition, variability of color judgments was increased by an illuminant shift and decreased by embedding the cube within a background. Taken together, these results suggest that in real 3D scenes with ample cues to object segregation, the addition of a background may improve stability of color identification.
Illumination Profile & Dispersion Variation Effects on Radial Velocity Measurements
NASA Astrophysics Data System (ADS)
Grieves, Nolan; Ge, Jian; Thomas, Neil B.; Ma, Bo; Li, Rui; SDSS-III
2015-01-01
The Multi-object APO Radial-Velocity Exoplanet Large-Area Survey (MARVELS) measures radial velocities using a fiber-fed dispersed fixed-delay interferometer (DFDI) with a moderate dispersion spectrograph. This setup allows a unique insight into the 2D illumination profile from the fiber on to the dispersion grating. Illumination profile investigations show large changes in the profile over time and fiber location. These profile changes are correlated with dispersion changes and long-term radial velocity offsets, a major problem within the MARVELS radial velocity data. Characterizing illumination profiles creates a method to both detect and correct radial velocity offsets, allowing for better planet detection. Here we report our early results from this study including improvement of radial velocity data points from detected giant planet candidates. We also report an illumination profile experiment conducted at the Kitt Peak National Observatory using the EXPERT instrument, which has a DFDI mode similar to MARVELS. Using profile controlling octagonal-shaped fibers, long term offsets over a 3 month time period were reduced from ~50 m/s to within the photon limit of ~4 m/s.
Jing, Lei; Wang, Yao; Zhao, Huifu; Ke, Hongliang; Wang, Xiaoxun; Gao, Qun
2017-06-10
In order to meet the requirements of uniform illumination for optical palm/fingerprint instruments and overcome the shortcomings of the poor uniform illumination on the working plane of the optical palm/fingerprint prism, a novel secondary optical lens with a free-form surface, compact structure, and high uniformity is presented in this paper. The design of the secondary optical lens is based on emission properties of the near-infrared light-emitting diode (LED) and basic principles of non-imaging optics, especially considering the impact of the thickness of the prism in the design. Through the numerical solution of Snell's law in geometric optics, we obtain the profile of the free-form surface of the lens. Using the optical software TracePro, we trace and simulate the illumination system. The results show that the uniformity is 89.8% on the working plane of the prism, and the test results show that the actual uniformity reaches 85.7% in the experiment, which provides an effective way for realizing a highly uniform illumination system with high-power near-infrared LED.
NASA Astrophysics Data System (ADS)
Świrniak, Grzegorz; Głomb, Grzegorz
2017-06-01
This study reports an application of a fiber-optic LED-based illumination system to solve an inverse problem in optical measurements of characteristics of a single-mode fiber. The illumination system has the advantages of low temporal coherence, high intensity, collimation, and thermal stability of the emission spectrum. The inverse analysis is investigated to predict the values of the diameter and refractive index of a single-mode fiber and applies to the far field scattering pattern in the vicinity of a polychromatic rainbow. As the inversion possibility depends considerably on the properties of the incident radiation, a detailed discussion is provided on both the specification of the illumination system as well as preliminary characteristics of the produced radiation. The illumination system uses a direct coupling between a thermally-stabilized LED junction and a plastic optical fiber, which transmits light to an optical collimator. A numerical study of fiber-to-LED coupling efficiency helps to understand the influence of lateral and longitudinal misalignments on the output power.
A programmable light engine for quantitative single molecule TIRF and HILO imaging.
van 't Hoff, Marcel; de Sars, Vincent; Oheim, Martin
2008-10-27
We report on a simple yet powerful implementation of objective-type total internal reflection fluorescence (TIRF) and highly inclined and laminated optical sheet (HILO, a type of dark-field) illumination. Instead of focusing the illuminating laser beam to a single spot close to the edge of the microscope objective, we are scanning during the acquisition of a fluorescence image the focused spot in a circular orbit, thereby illuminating the sample from various directions. We measure parameters relevant for quantitative image analysis during fluorescence image acquisition by capturing an image of the excitation light distribution in an equivalent objective backfocal plane (BFP). Operating at scan rates above 1 MHz, our programmable light engine allows directional averaging by circular spinning the spot even for sub-millisecond exposure times. We show that restoring the symmetry of TIRF/HILO illumination reduces scattering and produces an evenly lit field-of-view that affords on-line analysis of evanescnt-field excited fluorescence without pre-processing. Utilizing crossed acousto-optical deflectors, our device generates arbitrary intensity profiles in BFP, permitting variable-angle, multi-color illumination, or objective lenses to be rapidly exchanged.
Hybrid sunlight/LED illumination and renewable solar energy saving concepts for indoor lighting.
Tsuei, Chih-Hsuan; Sun, Wen-Shing; Kuo, Chien-Cheng
2010-11-08
A hybrid method for using sunlight and light-emitting diode (LED) illumination powered by renewable solar energy for indoor lighting is simulated and presented in this study. We can illuminate an indoor space and collect the solar energy using an optical switching system. When the system is turned off, the full spectrum of the sunlight is concentrated by a concentrator, to be absorbed by solar photovoltaic devices that provide the electricity to power the LEDs. When the system is turned on, the sunlight collected by the concentrator is split into visible and non-visible rays by a beam splitter. The visible rays pass through the light guide into a light box where it is mixed with LED light to ultimately provide uniform illumination by a diffuser. The non-visible rays are absorbed by the solar photovoltaic devices to provide electrical power for the LEDs. Simulation results show that the efficiency of the hybrid sunlight/LED illumination with the renewable solar energy saving design is better than that of LED and traditional lighting systems.
Distance Determination by Gated Viewing Systems Taking into Account the Illuminating Pulse Shape
NASA Astrophysics Data System (ADS)
Gorobets, V. A.; Kuntsevich, B. F.; Shabrov, D. V.
2017-11-01
For gated viewing systems with triangular and trapezoidal illuminating pulses, we have obtained the range-intensity profiles (RIPs) of the signal as the time delay was varied between the leading edges of the gate pulse and the illuminating pulse. We have established that if the duration of the illuminating pulse Δtlas is less than or equal to the duration of the gate pulse ΔtIC, then the expressions for the characteristic distances are the same as for rectangular pulses and they can be used to determine the distance to objects. When Δtlas > ΔtIC, in the case of triangular illuminating pulses the RIP is bell-shaped. For trapezoidal pulses, the RIP is bell-shaped with or without a plateau section. We propose an empirical method for determining the characteristic distances to the RIP maximum and the boundary points for the plateau section, which we then use to calculate the distance to the object. Using calibration constants, we propose a method for determining the distance to an object and we have experimentally confirmed the feasibility of this method.
Hyperbolic umbilic caustics from oblate water drops with tilted illumination: Observations
NASA Astrophysics Data System (ADS)
Jobe, Oli; Thiessen, David B.; Marston, Philip L.
2017-11-01
Various groups have reported observations of hyperbolic umbilic diffraction catastrophe patterns in the far-field scattering by oblate acoustically levitated drops with symmetric illumination. In observations of that type the drop's symmetry axis is vertical and the illuminating light beam (typically an expanded laser beam) travels horizontally. In the research summarized here, scattering patterns in the primary rainbow region and drop measurements were recorded with vertically tilted laser beam illumination having a grazing angle as large as 4 degrees. The findings from these observations may be summarized as follows: (a) It remains possible to adjust the drop aspect ratio (diameter/height) = D/H so as to produce a V-shaped hyperbolic umbilic focal section (HUFS) in the far-field scattering. (b) The shift in the required D/H was typically an increase of less than 1% and was quadratic in the tilt. (c) The apex of the V-shaped HUFS was shifted vertically by an amount proportional to the tilt with a coefficient close to unity. The levitated drops had negligible up-down asymmetry. Our method of investigation should be useful for other generalized rainbows with tilted illumination.
Namiki, Kana; Miyawaki, Atsushi; Ishikawa, Takuji
2017-01-01
Whole slide imaging (WSI) is a useful tool for multi-modal imaging, and in our work, we have often combined WSI with darkfield microscopy. However, traditional darkfield microscopy cannot use a single condenser to support high- and low-numerical-aperture objectives, which limits the modality of WSI. To overcome this limitation, we previously developed a darkfield internal reflection illumination (DIRI) microscope using white light-emitting diodes (LEDs). Although the developed DIRI is useful for biological applications, substantial problems remain to be resolved. In this study, we propose a novel illumination technique called color DIRI. The use of three-color LEDs dramatically improves the capability of the system, such that color DIRI (1) enables optimization of the illumination color; (2) can be combined with an oil objective lens; (3) can produce fluorescence excitation illumination; (4) can adjust the wavelength of light to avoid cell damage or reactions; and (5) can be used as a photostimulator. These results clearly illustrate that the proposed color DIRI can significantly extend WSI modalities for biological applications. PMID:28085892
Adaptive enhancement for nonuniform illumination images via nonlinear mapping
NASA Astrophysics Data System (ADS)
Wang, Yanfang; Huang, Qian; Hu, Jing
2017-09-01
Nonuniform illumination images suffer from degenerated details because of underexposure, overexposure, or a combination of both. To improve the visual quality of color images, underexposure regions should be lightened, whereas overexposure areas need to be dimmed properly. However, discriminating between underexposure and overexposure is troublesome. Compared with traditional methods that produce a fixed demarcation value throughout an image, the proposed demarcation changes as local luminance varies, thus is suitable for manipulating complicated illumination. Based on this locally adaptive demarcation, a nonlinear modification is applied to image luminance. Further, with the modified luminance, we propose a nonlinear process to reconstruct a luminance-enhanced color image. For every pixel, this nonlinear process takes the luminance change and the original chromaticity into account, thus trying to avoid exaggerated colors at dark areas and depressed colors at highly bright regions. Finally, to improve image contrast, a local and image-dependent exponential technique is designed and applied to the RGB channels of the obtained color image. Experimental results demonstrate that our method produces good contrast and vivid color for both nonuniform illumination images and images with normal illumination.
Laser diode stack beam shaping for efficient and compact long-range laser illuminator design
NASA Astrophysics Data System (ADS)
Lutz, Y.; Poyet, J. M.
2014-04-01
Laser diode stacks are interesting laser sources for active imaging illuminators. They allow the accumulation of large amounts of energy in multi-pulse mode, which is best suited for long-range image recording. Even when the laser diode stacks are equipped with fast-axis collimation (FAC) and slow-axis collimation (SAC) micro-lenses, their beam parameter products BPP are not compatible with direct use in highly efficient and compact illuminators. This is particularly true when narrow divergences are required such as for long-range applications. A solution to overcome these difficulties is to enhance the poor slow-axis BPP by virtually restacking the laser diode stack. We present a beam shaping and homogenization method that is low-cost and efficient and has low alignment sensitivity. After conducting simulations, we have realized and characterized the illuminator. A compact long-range laser illuminator has been set up with a divergence of 3.5×2.6 mrad and a global efficiency of 81%. Here, a projection lens with a clear aperture of 62 mm and a focal length of 571 mm was used.
Effects of 780 nm Optical Illumination on Loss in Superconducting Microwave Resonator
NASA Astrophysics Data System (ADS)
Budoyo, R. P.; Hertzberg, J. B.; Ballard, C. J.; Voigt, K. D.; Hoffman, J. E.; Grover, J. A.; Solano, P.; Lee, J.; Rolston, S. L.; Orozco, L. A.; Anderson, J. R.; Lobb, C. J.; Wellstood, F. C.
2015-03-01
Understanding the effects of light incident on a superconducting circuit is an important step toward building a hybrid quantum system where a superconducting qubit or resonator is coupled to atoms trapped on a tapered optical fiber. We fabricated a microscale thin-film Al superconducting LC resonator (frequency 6.72 GHz) on sapphire substrate and mounted it inside an Al 3d cavity (TE101 mode frequency 7.50 GHz). Using an optical fiber, we illuminated the resonator with 780 nm light, and measured the change in internal quality factor and resonant frequency of the resonator as a function of applied optical power. The results suggest that the illumination causes an increase in rf drive-dependent dissipation. While optical illumination is expected to enhance dissipation due to quasiparticles, rf drive dependence is more typically seen in two-level-system dissipation. We compare the results with the change in loss from increased resonator temperature, and discuss various mechanisms of loss from optical illumination. Work supported by NSF through the Physics Frontier Center at the Joint Quantum Institute (JQI), and by the Center of Nanophysics and Advanced Materials (CNAM).
NASA Astrophysics Data System (ADS)
Zhai, Peng; Lee, Hyeonseok; Huang, Yu-Ting; Wei, Tzu-Chien; Feng, Shien-Ping
2016-10-01
In this study, ultrasmall and ultrafine TiO2 quantum dots (QDs) were prepared and used as a high-performance compact layer (CL) in dye-sensitized solar cells (DSCs). We systematically investigated the performance of TiO2 CL under both low-intensity light and indoor fluorescent light illumination and found that the efficiency of DSCs with the insertion of optimal TiO2 QDs-CL was increased up to 18.3% under indoor T5 fluorescent light illumination (7000 lux). We clarified the controversy over the blocking effect of TiO2 CL for the efficiency increment and confirmed that the TiO2 QDs-CL performed significantly better under low-intensity illumination due to the efficient suppression of electron recombination at the FTO/electrolyte interface. We, for the first time, demonstrate this potential for the application of the DSCs with TiO2 QDs-CL in the low-intensity light and indoor fluorescent light illumination.
Nighttime highway construction illumination.
DOT National Transportation Integrated Search
2014-08-01
The nighttime driving environment, consisting of roadway illumination, signs, vehicle lighting and markers, delineators : and flashing lights, can be complex or even confusing for both pedestrians and drivers. The nighttime construction : environment...
Vinogradova, I A; Bukalev, A V; Zabezhinski, M A; Semenchenko, A V; Khavinson, V Kh; Anisimov, V N
2008-04-01
Exposure of male rats to permanent or natural illumination of North-Western Russia accelerated their death in comparison with animals exposed to standard (12 h) light. Permanent illumination promoted the development of spontaneous tumors in comparison with the standard photoregimen. Injection of epithalone (synthetic Ala-Glu-Asp-Gly peptide; subcutaneously 0.1 microg/rat 5 times a week from the age of 4 months until natural death) virtually did not change the mean lifespan of male rats, but was associated with a significant (p<0.05) normalization of population aging rate and hence, time of mortality rate doubling in groups exposed to natural or constant illumination. Epithalone injected to rats exposed to any photoregimen significantly inhibited the development of spontaneous tumors, primarily testicular leydigomas and leukemias.
A back-illuminated megapixel CMOS image sensor
NASA Technical Reports Server (NTRS)
Pain, Bedabrata; Cunningham, Thomas; Nikzad, Shouleh; Hoenk, Michael; Jones, Todd; Wrigley, Chris; Hancock, Bruce
2005-01-01
In this paper, we present the test and characterization results for a back-illuminated megapixel CMOS imager. The imager pixel consists of a standard junction photodiode coupled to a three transistor-per-pixel switched source-follower readout [1]. The imager also consists of integrated timing and control and bias generation circuits, and provides analog output. The analog column-scan circuits were implemented in such a way that the imager could be configured to run in off-chip correlated double-sampling (CDS) mode. The imager was originally designed for normal front-illuminated operation, and was fabricated in a commercially available 0.5 pn triple-metal CMOS-imager compatible process. For backside illumination, the imager was thinned by etching away the substrate was etched away in a post-fabrication processing step.
NASA Astrophysics Data System (ADS)
Mitic, Jelena; Anhut, Tiemo; Serov, Alexandre; Lasser, Theo; Bourquin, Stephane
2003-07-01
Real-time optically sectioned microscopy is demonstrated using an AC-sensitive detection concept realized with smart CMOS image sensor and structured light illumination by a continuously moving periodic pattern. We describe two different detection systems based on CMOS image sensors for the detection and on-chip processing of the sectioned images in real time. A region-of-interest is sampled at high frame rate. The demodulated signal delivered by the detector corresponds to the depth discriminated image of the sample. The measured FWHM of the axial response depends on the spatial frequency of the projected grid illumination and is in the μm-range. The effect of using broadband incoherent illumination is discussed. The performance of these systems is demonstrated by imaging technical as well as biological samples.
Choi, Heejin; Wadduwage, Dushan; Matsudaira, Paul T.; So, Peter T.C.
2014-01-01
A depth resolved hyperspectral imaging spectrometer can provide depth resolved imaging both in the spatial and the spectral domain. Images acquired through a standard imaging Fourier transform spectrometer do not have the depth-resolution. By post processing the spectral cubes (x, y, λ) obtained through a Sagnac interferometer under uniform illumination and structured illumination, spectrally resolved images with depth resolution can be recovered using structured light illumination algorithms such as the HiLo method. The proposed scheme is validated with in vitro specimens including fluorescent solution and fluorescent beads with known spectra. The system is further demonstrated in quantifying spectra from 3D resolved features in biological specimens. The system has demonstrated depth resolution of 1.8 μm and spectral resolution of 7 nm respectively. PMID:25360367
Numerical analysis of lateral illumination lightpipes using elliptical grooves
NASA Astrophysics Data System (ADS)
Sánchez-Guerrero, Guillermo E.; Viera-González, Perla M.; Martínez-Guerra, Edgar; Ceballos-Herrera, Daniel E.
2017-09-01
Lightpipes are used for illumination in applications such as back-lighting or solar cell concentrators due to the high irradiance uniformity, but its optimal design requires several parameters. This work presents a procedure to design a square lightpipe to control the light-extraction on its lateral face using commercial LEDs placed symmetrically in the lightpipe frontal face. We propose the use of grooves using total internal reflection placed successively in the same face of extraction to control the area of emission. The LED area of emission is small compared with the illuminated area, and, as expected, the lateral face total power is attenuated. These grooves reduce the optical elements in the system and can control areas of illumination. A mathematical and numerical analysis are presented to determine the dependencies on the light-extraction.
NASA Astrophysics Data System (ADS)
Shinde, Anant; Perinchery, Sandeep Menon; Murukeshan, Vadakke Matham
2017-04-01
An optical imaging probe with targeted multispectral and spatiotemporal illumination features has applications in many diagnostic biomedical studies. However, these systems are mostly adapted in conventional microscopes, limiting their use for in vitro applications. We present a variable resolution imaging probe using a digital micromirror device (DMD) with an achievable maximum lateral resolution of 2.7 μm and an axial resolution of 5.5 μm, along with precise shape selective targeted illumination ability. We have demonstrated switching of different wavelengths to image multiple regions in the field of view. Moreover, the targeted illumination feature allows enhanced image contrast by time averaged imaging of selected regions with different optical exposure. The region specific multidirectional scanning feature of this probe has facilitated high speed targeted confocal imaging.
Multispectral Scanner for Monitoring Plants
NASA Technical Reports Server (NTRS)
Gat, Nahum
2004-01-01
A multispectral scanner has been adapted to capture spectral images of living plants under various types of illumination for purposes of monitoring the health of, or monitoring the transfer of genes into, the plants. In a health-monitoring application, the plants are illuminated with full-spectrum visible and near infrared light and the scanner is used to acquire a reflected-light spectral signature known to be indicative of the health of the plants. In a gene-transfer- monitoring application, the plants are illuminated with blue or ultraviolet light and the scanner is used to capture fluorescence images from a green fluorescent protein (GFP) that is expressed as result of the gene transfer. The choice of wavelength of the illumination and the wavelength of the fluorescence to be monitored depends on the specific GFP.
Photo-induced-heat localization on nanostructured metallic glasses
NASA Astrophysics Data System (ADS)
Uzun, Ceren; Kahler, Niloofar; Grave de Peralta, Luis; Kumar, Golden; Bernussi, Ayrton A.
2017-09-01
Materials with large photo-thermal energy conversion efficiency are essential for renewable energy applications. Photo-excitation is an effective approach to generate controlled and localized heat at relatively low excitation optical powers. However, lateral heat diffusion to the surrounding illuminated areas accompanied by low photo-thermal energy conversion efficiency remains a challenge for metallic surfaces. Surface nanoengineering has proven to be a successful approach to further absorption and heat generation. Here, we show that pronounced spatial heat localization and high temperatures can be achieved with arrays of amorphous metallic glass nanorods under infrared optical illumination. Thermography measurements revealed marked temperature contrast between illuminated and non-illuminated areas even under low optical power excitation conditions. This attribute allowed for generating legible photo-induced thermal patterns on textured metallic glass surfaces.
Fiber Optical Improvements for a Device Used in Laparoscopic Hysterectomy Surgery
NASA Astrophysics Data System (ADS)
Hernández Garcia, Ricardo; Vázquez Mercado, Liliana; García-Torales, G.; Flores, Jorge L.; Barcena-Soto, Maximiliano; Casillas Santana, Norberto; Casillas Santana, Juan Manuel
2006-09-01
Hysterectomy removes uterus from patients suffering different pathologies. One of the most common techniques for performing it is the laparoscopically-assisted vaginal hysterectomy (LAVH). In the final stage of the procedure, surgeons face the need to unambiguously identify the vaginal cuff before uterus removal. The aim of this research is to adapt a local source of illumination to a polymer cup-like device adapted to a stainless steel shaft that surgeons nowadays use to manipulate the uterus in LAVH. Our proposal consists in implementing a set of optical fiber illuminators along the border of the cup-like device to illuminate the exact vaginal cupola, using an external light source. We present experimental results concerning temperature increases in quasi adiabatic conditions in cow meat under different light intensity illumination.
NASA Astrophysics Data System (ADS)
Speyerer, E.; Koeber, S.; Robinson, M. S.
2010-12-01
The spin axis of the Moon is tilted by only 1.5° (compared with the Earth's 23.5°), leaving some areas near the poles in permanent shadow while other nearby regions remain sunlit for a majority of the year. Theory, radar data, neutron measurements, and Lunar CRater Observation and Sensing Satellite (LCROSS) observations suggest that volatiles may be present in the cold traps created inside these permanently shadowed regions. While areas of near permanent illumination are prime locations for future lunar outposts due to benign thermal conditions and near constant solar power. The Lunar Reconnaissance Orbiter (LRO) has two imaging systems that provide medium and high resolution views of the poles. During almost every orbit the LROC Wide Angle Camera (WAC) acquires images at 100 m/pixel of the polar region (80° to 90° north and south latitude). In addition, the LROC Narrow Angle Camera (NAC) targets selected regions of interest at 0.7 to 1.5 m/pixel [Robinson et al., 2010]. During the first 11 months of the nominal mission, LROC acquired almost 6,000 WAC images and over 7,300 NAC images of the polar region (i.e., within 2° of pole). By analyzing this time series of WAC and NAC images, regions of permanent shadow and permanent, or near-permanent illumination can be quantified. The LROC Team is producing several reduced data products that graphically illustrate the illumination conditions of the polar regions. Illumination movie sequences are being produced that show how the lighting conditions change over a calendar year. Each frame of the movie sequence is a polar stereographic projected WAC image showing the lighting conditions at that moment. With the WAC’s wide field of view (~100 km at an altitude of 50 km), each frame has repeat coverage between 88° and 90° at each pole. The same WAC images are also being used to develop multi-temporal illumination maps that show the percent each 100 m × 100 m area is illuminated over a period of time. These maps are derived by stacking all the WAC frames, selecting a threshold to determine if the surface is illuminated, and summing the resulting binary images. In addition, mosaics of NAC images are also being produced for regions of interest at a scale of 0.7 to 1.5 m/pixel. The mosaics produced so far have revealed small illuminated surfaces on the tens of meters scale that were previously thought to be shadowed during that time. The LROC dataset of the polar regions complements previous illumination analysis of Clementine images [Bussey et al., 1999], Kaguya topography [Bussey et al., 2010], and the current efforts underway by the Lunar Orbiter Laser Altimeter (LOLA) Team [Mazarico et al., 2010] and provide an important new dataset for science and exploration. References: Bussey et al. (1999), Illumination conditions at the lunar south pole, Geophysical Research Letters, 26(9), 1187-1190. Bussey et al. (2010), Illumination conditions of the south pole of the Moon derived from Kaguya topography, Icarus, 208, 558-564. Mazarico et al. (2010), Illumination of the lunar poles from the Lunar Orbiter Laser Altimeter (LOLA) Topography Data, paper presented at 41st LPSC, Houston, TX. Robinson et al. (2010), Lunar Reconnaissance Orbiter Camera (LROC) Instrument Overview, Space Sci Rev, 150, 81-124.
Fiber Coupled Laser Diodes with Even Illumination Pattern
NASA Technical Reports Server (NTRS)
Howard, Richard T. (Inventor)
2007-01-01
An optical fiber for evenly illuminating a target. The optical fiber is coupled to a laser emitting diode and receives laser light. The la ser light travels through the fiber optic and exits at an exit end. T he exit end has a diffractive optical pattern formed thereon via etch ing, molding or cutting, to reduce the Gaussian profile present in co nventional fiber optic cables The reduction of the Gaussian provides an even illumination from the fiber optic cable.
Improvement of image quality of coherently illuminated objects in a turbulent atmosphere
NASA Astrophysics Data System (ADS)
Banakh, Viktor A.; Chen, Ben-Nam
1994-06-01
It is shown that the phenomenon of correlation of opposing waves may lead to improvement of image quality of coherently illuminated objects in a turbulent atmosphere in the case of strong intensity fluctuations. The extent of this improvement depends on the relation between sizes of the output and receiving apertures. The betterment of visibility in a turbulent atmosphere becomes maximal in the case of their proximity and vanishes if the sizes of illuminating and receiving apertures are distinguished from each other significantly.
Beam/seam alignment control for electron beam welding
Burkhardt, Jr., James H.; Henry, J. James; Davenport, Clyde M.
1980-01-01
This invention relates to a dynamic beam/seam alignment control system for electron beam welds utilizing video apparatus. The system includes automatic control of workpiece illumination, near infrared illumination of the workpiece to limit the range of illumination and camera sensitivity adjustment, curve fitting of seam position data to obtain an accurate measure of beam/seam alignment, and automatic beam detection and calculation of the threshold beam level from the peak beam level of the preceding video line to locate the beam or seam edges.
Long duration exposure facility solar illumination data package
NASA Technical Reports Server (NTRS)
Berrios, William M.; Sampair, Thomas
1990-01-01
A post flight solar illumination data package was created by the LDEF thermal analysis data group in support of the LDEF science office data group. The data presented was prepared with the Thermal Radiation Analysis System (TRASYS) program. Ground tracking data was used to calculate daily orbital beta angles for the calculation of resultant fluxes. This data package will be useful in calculation of solar illumination fluent for a variety of beta angle orbital conditions encountered during the LDEF mission.
New techniques for fluorescence background rejection in microscopy and endoscopy
NASA Astrophysics Data System (ADS)
Ventalon, Cathie
2009-03-01
Confocal microscopy is a popular technique in the bioimaging community, mainly because it provides optical sectioning. However, its standard implementation requires 3-dimensional scanning of focused illumination throughout the sample. Efficient non-scanning alternatives have been implemented, among which the simple and well-established incoherent structured illumination microscopy (SIM) [1]. We recently proposed a similar technique, called Dynamic Speckle Illumination (DSI) microscopy, wherein the incoherent grid illumination pattern is replaced with a coherent speckle illumination pattern from a laser, taking advantage of the fact that speckle contrast is highly maintained in a scattering media, making the technique well adapted to tissue imaging [2]. DSI microscopy relies on the illumination of a sample with a sequence of dynamic speckle patterns and an image processing algorithm based only on an a priori knowledge of speckle statistics. The choice of this post-processing algorithm is crucial to obtain a good sectioning strength: in particular, we developed a novel post-processing algorithm based one wavelet pre-filtering of the raw images and obtained near-confocal fluorescence sectioning in a mouse brain labeled with GFP, with a good image quality maintained throughout a depth of ˜100 μm [3]. In the purpose of imaging fluorescent tissue at higher depth, we recently applied structured illumination to endoscopy. We used a similar set-up wherein the illumination pattern (a one-dimensional grid) is transported to the sample with an imaging fiber bundle with miniaturized objective and the fluorescence image is collected through the same bundle. Using a post-processing algorithm similar to the one previously described [3], we obtained high-quality images of a fluorescein-labeled rat colonic mucosa [4], establishing the potential of our endomicroscope for bioimaging applications. [4pt] Ref: [0pt] [1] M. A. A. Neil et al, Opt. Lett. 22, 1905 (1997) [0pt] [2] C. Ventalon et al, Opt. Lett. 30, 3350 (2005) [0pt] [3] C. Ventalon et al, Opt. Lett. 32, 1417 (2007) [0pt] [4] N. Bozinovic et al, Opt. Express 16, 8016 (2008)
The effect of bright light on lens compensation in chicks.
Ashby, Regan S; Schaeffel, Frank
2010-10-01
It has been shown that sunlight or bright indoor light can inhibit the development of deprivation myopia in chicks. It remains unclear whether light merely acts on deprivation myopia or, more generally, modulates the rate of emmetropization and its set point. This study was conducted to test how bright light interacts with compensation for imposed optical defocus. Furthermore, a dopamine antagonist was applied to test whether the protective effect of light is mediated by dopamine. Experiment A: Chicks monocularly wore either -7 or +7 D lenses for a period of 5 days, either under normal laboratory illuminance (500 lux, n = 12 and 16, respectively) or under high ambient illuminance (15,000 lux, n = 12 and 16). Experiment B: Chicks wore diffusers for a period of 4 days, either under normal laboratory illuminance (500 lux, n = 9) or high ambient illuminance (15,000 lux), with the bright-light group intravitreally injected daily with either the dopamine D(2) antagonist spiperone (500 μM, n = 9) or a vehicle solution (0.1% ascorbic acid, n = 9), with an untreated group serving as the control (n = 6). Axial length and refraction were measured at the commencement and cessation of all treatments. Exposure to high illuminances (15,000 lux) for 5 hours per day significantly slowed compensation for negative lenses, compared with that seen under 500 lux, although full compensation was still achieved. Compensation for positive lenses was accelerated by exposure to high illuminances but, again, the end point refraction was unchanged, compared with that of the 500-lux group. High illuminance also reduced deprivation myopia by roughly 60%, compared with that seen under 500 lux. This protective effect was abolished, however, by the daily injection of spiperone, but was unaffected by the injection of a vehicle solution. High illuminance levels reduce the rate of compensation for negative lenses and enhance the rate for positive lenses, but do not change the set point of emmetropization (target refraction). The retardation of myopia development by light is partially mediated by dopamine, as the injection of a dopamine antagonist abolishes the protective effect of light, at least in the case of deprivation myopia.
Wood's lamp illumination (image)
A Wood's lamp emits ultraviolet light and can be a diagnostic aid in determining if someone has a fungal ... is an infection on the area where the Wood's lamp is illuminating, the area will fluoresce. Normally ...
Overhead guide sign retroreflectivity and illumination.
DOT National Transportation Integrated Search
2015-01-01
Roadway guide sign visibility during darkness is fundamental to driver safety, especially elderly drivers. Guide : sign visibility can be improved by external sign illumination or the use of retroreflective sheeting on signs. Because : energy conserv...
A Physics-Based Deep Learning Approach to Shadow Invariant Representations of Hyperspectral Images.
Windrim, Lloyd; Ramakrishnan, Rishi; Melkumyan, Arman; Murphy, Richard J
2018-02-01
This paper proposes the Relit Spectral Angle-Stacked Autoencoder, a novel unsupervised feature learning approach for mapping pixel reflectances to illumination invariant encodings. This work extends the Spectral Angle-Stacked Autoencoder so that it can learn a shadow-invariant mapping. The method is inspired by a deep learning technique, Denoising Autoencoders, with the incorporation of a physics-based model for illumination such that the algorithm learns a shadow invariant mapping without the need for any labelled training data, additional sensors, a priori knowledge of the scene or the assumption of Planckian illumination. The method is evaluated using datasets captured from several different cameras, with experiments to demonstrate the illumination invariance of the features and how they can be used practically to improve the performance of high-level perception algorithms that operate on images acquired outdoors.
Improving high resolution retinal image quality using speckle illumination HiLo imaging
Zhou, Xiaolin; Bedggood, Phillip; Metha, Andrew
2014-01-01
Retinal image quality from flood illumination adaptive optics (AO) ophthalmoscopes is adversely affected by out-of-focus light scatter due to the lack of confocality. This effect is more pronounced in small eyes, such as that of rodents, because the requisite high optical power confers a large dioptric thickness to the retina. A recently-developed structured illumination microscopy (SIM) technique called HiLo imaging has been shown to reduce the effect of out-of-focus light scatter in flood illumination microscopes and produce pseudo-confocal images with significantly improved image quality. In this work, we adopted the HiLo technique to a flood AO ophthalmoscope and performed AO imaging in both (physical) model and live rat eyes. The improvement in image quality from HiLo imaging is shown both qualitatively and quantitatively by using spatial spectral analysis. PMID:25136486
Improving high resolution retinal image quality using speckle illumination HiLo imaging.
Zhou, Xiaolin; Bedggood, Phillip; Metha, Andrew
2014-08-01
Retinal image quality from flood illumination adaptive optics (AO) ophthalmoscopes is adversely affected by out-of-focus light scatter due to the lack of confocality. This effect is more pronounced in small eyes, such as that of rodents, because the requisite high optical power confers a large dioptric thickness to the retina. A recently-developed structured illumination microscopy (SIM) technique called HiLo imaging has been shown to reduce the effect of out-of-focus light scatter in flood illumination microscopes and produce pseudo-confocal images with significantly improved image quality. In this work, we adopted the HiLo technique to a flood AO ophthalmoscope and performed AO imaging in both (physical) model and live rat eyes. The improvement in image quality from HiLo imaging is shown both qualitatively and quantitatively by using spatial spectral analysis.
Video repairing under variable illumination using cyclic motions.
Jia, Jiaya; Tai, Yu-Wing; Wu, Tai-Pang; Tang, Chi-Keung
2006-05-01
This paper presents a complete system capable of synthesizing a large number of pixels that are missing due to occlusion or damage in an uncalibrated input video. These missing pixels may correspond to the static background or cyclic motions of the captured scene. Our system employs user-assisted video layer segmentation, while the main processing in video repair is fully automatic. The input video is first decomposed into the color and illumination videos. The necessary temporal consistency is maintained by tensor voting in the spatio-temporal domain. Missing colors and illumination of the background are synthesized by applying image repairing. Finally, the occluded motions are inferred by spatio-temporal alignment of collected samples at multiple scales. We experimented on our system with some difficult examples with variable illumination, where the capturing camera can be stationary or in motion.
Real-time traffic sign recognition based on a general purpose GPU and deep-learning.
Lim, Kwangyong; Hong, Yongwon; Choi, Yeongwoo; Byun, Hyeran
2017-01-01
We present a General Purpose Graphics Processing Unit (GPGPU) based real-time traffic sign detection and recognition method that is robust against illumination changes. There have been many approaches to traffic sign recognition in various research fields; however, previous approaches faced several limitations when under low illumination or wide variance of light conditions. To overcome these drawbacks and improve processing speeds, we propose a method that 1) is robust against illumination changes, 2) uses GPGPU-based real-time traffic sign detection, and 3) performs region detecting and recognition using a hierarchical model. This method produces stable results in low illumination environments. Both detection and hierarchical recognition are performed in real-time, and the proposed method achieves 0.97 F1-score on our collective dataset, which uses the Vienna convention traffic rules (Germany and South Korea).
Integration of non-Lambertian LED and reflective optical element as efficient street lamp.
Pan, Jui-Wen; Tu, Sheng-Han; Sun, Wen-Shing; Wang, Chih-Ming; Chang, Jenq-Yang
2010-06-21
A cost effective, high throughput, and high yield method for the increase of street lamp potency was proposed in this paper. We integrated the imprinting technology and the reflective optical element to obtain a street lamp with high illumination efficiency and without glare effect. The imprinting technique can increase the light extraction efficiency and modulate the intensity distribution in the chip level. The non-Lambertian light source was achieved by using imprinting technique. The compact reflective optical element was added to efficiently suppress the emitting light intensity with small emitting angle for the uniform of illumination intensity and excluded the light with high emitting angle for the prevention of glare. Compared to the conventional street lamp, the novel design has 40% enhancement in illumination intensity, the uniform illumination and the glare effect elimination.
NASA Astrophysics Data System (ADS)
Koelbl, Philipp Simon; Koch, Frank H. J.; Lingenfelder, Christian; Hessling, Martin
2018-02-01
The illumination of the intraocular space during pars plana vitrectomy always bears the risk of retina damage by irradiation. Conventional illumination systems consist of an external light source and an optical fiber to transfer the visible light (radiation) into the eye. Often xenon arc and halogen lamps are employed for this application with some disadvantageous properties like high phototoxicity and low efficiency. Therefore, we propose to generate the light directly within the eye by inserting a white micro LED with a diameter of 0.6 mm. The LED offers a luminous flux of 0.6 lm of white light with a blue peak @ 450 nm and a yellow peak @ 555 nm. The presented prototypes fit through a standard 23 G trocar and are the first intraocular light sources worldwide. Two different single-use approaches have already been developed: a handguided and a chandelier device. The hand-guided applicator enables a directly navigation and illumination up to a working distance of 6 mm. The chandelier device is much smaller and does not need an active navigation of the light cone. The brightness and homogeneity of the illumination of these LED devices have been successfully tested on porcine eyes. Presented measurements and calculations prove that even for high LED currents and small distances to the retina these intraocular micro LED devices expose the retina to less hazard than conventional illumination sources like fiber based xenon systems. Even under the worst circumstances application durations of 180 hours would be justifiable.
NASA Astrophysics Data System (ADS)
Bok, Tae-Hoon; Hysi, Eno; Kolios, Michael C.
2017-03-01
In the present paper, the optical wavelength dependence on the photoacoustic (PA) assessment of the pulsatile blood flow was investigated by means of the experimental and theoretical approaches analyzing PA radiofrequency spectral parameters such as the spectral slope (SS) and mid-band fit (MBF). For the experimental approach, the pulsatile flow of human whole blood at 60 bpm was imaged using the VevoLAZR system (40-MHz-linear-array probe, 700-900 nm illuminations). For the theoretical approach, a Monte Carlo simulation for the light transmit into a layered tissue phantom and a Green's function based method for the PA wave generation was implemented for illumination wavelengths of 700, 750, 800, 850 and 900 nm. The SS and MBF for the experimental results were compared to theoretical ones as a function of the illumination wavelength. The MBF increased with the optical wavelength in both theory and experiments. This was expected because the MBF is representative of the PA magnitude, and the PA signal from red blood cell (RBC) is dependent on the molar extinction coefficient of oxyhemoglobin. On the other hand, the SS decreased with the wavelength, even though the RBC size (absorber size which is related to the SS) cannot depend on the illumination wavelength. This conflicting result can be interpreted by means of the changes of the fluence pattern for different illumination wavelengths. The SS decrease with the increasing illumination wavelength should be further investigated.
NASA Astrophysics Data System (ADS)
Roca, Ronel Christian; Nishizawa, Nozomi; Nishibayashi, Kazuhiro; Munekata, Hiro
2017-04-01
In view of a study on spin-polarized photodiodes, the helicity-dependent photocurrent (ΔI) in a Fe/γ-AlO x /p-GaAs Schottky diode is measured at room temperature by illuminating a circularly polarized light beam (λ = 785 nm) either horizontally on the cleaved sidewall or at an oblique angle on the top metal surface. The plane of incidence is fixed to be parallel to the magnetization vector of the in-plane magnetized Fe electrode. The conversion efficiency F, which is a relative value of ΔI with respect to the total photocurrent I ph, is determined to be 1.0 × 10-3 and 1.2 × 10-2 for sidewall illumination and oblique-angle illumination, respectively. Experimental data are compared with the results of a model calculation consisting of drift-diffusion and Julliere spin-dependent tunneling transports, from which two conclusions are obtained: the model accounts fairly well for the experimental data without introducing the annihilation of spin-polarized carriers at the γ-AlO x /p-GaAs interface for the oblique-angle illumination, but the model does not fully explain the relatively low F in terms of the surface recombination at the cleaved sidewall in the case of sidewall illumination. Microscopic damage to the tunneling barrier at the cleaved edge would be one possible cause of the reduced F.
Efficient Bifacial Semitransparent Perovskite Solar Cells Using Ag/V2O5 as Transparent Anodes.
Pang, Shangzheng; Li, Xueyi; Dong, Hang; Chen, Dazheng; Zhu, Weidong; Chang, Jingjing; Lin, Zhenhua; Xi, He; Zhang, Jincheng; Zhang, Chunfu; Hao, Yue
2018-04-18
Bifacial semitransparent inverted planar structured perovskite solar cells (PSCs) based on Cs 0.05 FA 0.3 MA 0.7 PbI 2.51 Br 0.54 using an Ag thin film electrode and V 2 O 5 optical coupling layer are investigated theoretically and experimentally. It is shown that the introduction of the cesium (Cs) ions in the perovskite could obviously improve the device performance and stability. When only the bare Ag film electrode is used, the PSCs show a bifacial performance with the power conversion efficiency (PCE) of 14.62% illuminated from the indium tin oxide (ITO) side and 5.45% from the Ag film side. By introducing a V 2 O 5 optical coupling layer, the PCE is enhanced to 8.91% illuminated from the Ag film side, which is 63% improvement compared with the bare Ag film electrode, whereas the PCE illuminated from the ITO side remains almost unchanged. Moreover, when a back-reflector is employed, the PCE of device could be further improved to 15.39% by illumination from the ITO side and 12.44% by illumination from the Ag side. The devices also show superior semitransparent properties and exhibit negligible photocurrent hysteresis, irrespective of the side from which the light is illuminated. In short, the Ag/V 2 O 5 double layer is a promising semitransparent electrode due to its low cost and simple preparation process, which also point to a new direction for the bifacial PSCs and tandem solar cells.
Volumetric bioimaging based on light field microscopy with temporal focusing illumination
NASA Astrophysics Data System (ADS)
Hsu, Feng-Chun; Sie, Yong Da; Lai, Feng-Jie; Chen, Shean-Jen
2018-02-01
Light field technique at a single shot can get the whole volume image of observed sample. Therefore, the original frame rate of the optical system can be taken as the volumetric image rate. For dynamically imaging whole micron-scale biosample, a light field microscope with temporal focusing illumination has been developed. In the light field microscope, the f-number of the microlens array (MLA) is adopted to match that of the objective; hence, the subimages via adjacent lenslets do not overlay each other. A three-dimensional (3D) deconvolution algorithm is utilized to deblur the out-of-focusing part. Conventional light field microscopy (LFM) illuminates whole volume sample even noninteresting parts; nevertheless, whole volume excitation causes even more damage on bio-sample and also increase the background noise from the out of range. Therefore, temporal focusing is integrated into the light field microscope for selecting the illumination volume. Herein, a slit on the back focal plane of the objective is utilized to control the axial excitation confinement for selecting the illumination volume. As a result, the developed light field microscope with the temporal focusing multiphoton illumination (TFMPI) can reconstruct 3D images within the selected volume, and the lateral resolution approaches to the theoretical value. Furthermore, the 3D Brownian motion of two-micron fluorescent beads is observed as the criterion of dynamic sample. With superior signal-to-noise ratio and less damage to tissue, the microscope is potential to provide volumetric imaging for vivo sample.
Lunar Polar Illumination for Power Analysis
NASA Technical Reports Server (NTRS)
Fincannon, James
2008-01-01
This paper presents illumination analyses using the latest Earth-based radar digital elevation model (DEM) of the lunar south pole and an independently developed analytical tool. These results enable the optimum sizing of solar/energy storage lunar surface power systems since they quantify the timing and durations of illuminated and shadowed periods. Filtering and manual editing of the DEM based on comparisons with independent imagery were performed and a reduced resolution version of the DEM was produced to reduce the analysis time. A comparison of the DEM with lunar limb imagery was performed in order to validate the absolute heights over the polar latitude range, the accuracy of which affects the impact of long range, shadow-casting terrain. Average illumination and energy storage duration maps of the south pole region are provided for the worst and best case lunar day using the reduced resolution DEM. Average illumination fractions and energy storage durations are presented for candidate low energy storage duration south pole sites. The best site identified using the reduced resolution DEM required a 62 hr energy storage duration using a fast recharge power system. Solar and horizon terrain elevations as well as illumination fraction profiles are presented for the best identified site and the data for both the reduced resolution and high resolution DEMs compared. High resolution maps for three low energy storage duration areas are presented showing energy storage duration for the worst case lunar day, surface height, and maximum absolute surface slope.
Joint estimation of motion and illumination change in a sequence of images
NASA Astrophysics Data System (ADS)
Koo, Ja-Keoung; Kim, Hyo-Hun; Hong, Byung-Woo
2015-09-01
We present an algorithm that simultaneously computes optical flow and estimates illumination change from an image sequence in a unified framework. We propose an energy functional consisting of conventional optical flow energy based on Horn-Schunck method and an additional constraint that is designed to compensate for illumination changes. Any undesirable illumination change that occurs in the imaging procedure in a sequence while the optical flow is being computed is considered a nuisance factor. In contrast to the conventional optical flow algorithm based on Horn-Schunck functional, which assumes the brightness constancy constraint, our algorithm is shown to be robust with respect to temporal illumination changes in the computation of optical flows. An efficient conjugate gradient descent technique is used in the optimization procedure as a numerical scheme. The experimental results obtained from the Middlebury benchmark dataset demonstrate the robustness and the effectiveness of our algorithm. In addition, comparative analysis of our algorithm and Horn-Schunck algorithm is performed on the additional test dataset that is constructed by applying a variety of synthetic bias fields to the original image sequences in the Middlebury benchmark dataset in order to demonstrate that our algorithm outperforms the Horn-Schunck algorithm. The superior performance of the proposed method is observed in terms of both qualitative visualizations and quantitative accuracy errors when compared to Horn-Schunck optical flow algorithm that easily yields poor results in the presence of small illumination changes leading to violation of the brightness constancy constraint.
MODIS Solar Diffuser Attenuation Screen Modeling Results
NASA Technical Reports Server (NTRS)
Waluschka, Eugene; Xuong, Xiaoxiong; Guenther, Bruce; Barnes, William
2004-01-01
On-orbit calibration of the reflected solar bands on the EOS Moderate Resolution Imaging Spectroradiometer (MODIS) is accomplished by have the instrument view a high reflectance diffuse surface illuminated by the sun. For some of the spectral bands this proves to be much too bright a signal that results in the saturation of detectors designed for measuring low reflectance (ocean) surfaces signals. A mechanical attenuation device in the form of a pin hole screen is used to reduce the signals to calibrate these bands. The sensor response to solar illumination of the SD with and without the attenuation screen in place will be presented. The MODIS detector response to the solar diffuser is smooth when the attenuation screen is absent, but has structures up to a few percent when the attenuation screen is present. This structure corresponds to non-uniform illumination from the solar diffuser. Each pin hole produces a pin-hole image of the sun on the solar diffuser, and there are very many pin hole images of the sun on the solar diffuser for each MODIS detector. Even though there are very many pin-hole images of the sun on the solar diffuser, it is no longer perfectly uniformly illuminated. This non-uniformly illuminated solar diffuser produces intensity variation on the focal planes. The results of a very detailed simulation will be discussed which show how the illumination of the focal plane changes as a result of the attenuation, and the impacts on the calibration will be discussed.
Use of astronomy filters in fluorescence microscopy.
Piper, Jörg
2012-02-01
Monochrome astronomy filters are well suited for use as excitation or suppression filters in fluorescence microscopy. Because of their particular optical design, such filters can be combined with standard halogen light sources for excitation in many fluorescent probes. In this "low energy excitation," photobleaching (fading) or other irritations of native specimens are avoided. Photomicrographs can be taken from living motile fluorescent specimens also with a flash so that fluorescence images can be created free from indistinctness caused by movement. Special filter cubes or dichroic mirrors are not needed for our method. By use of suitable astronomy filters, fluorescence microscopy can be carried out with standard laboratory microscopes equipped with condensers for bright-field (BF) and dark-field (DF) illumination in transmitted light. In BF excitation, the background brightness can be modulated in tiny steps up to dark or black. Moreover, standard industry microscopes fitted with a vertical illuminator for examinations of opaque probes in DF or BF illumination based on incident light (wafer inspections, for instance) can also be used for excitation in epi-illumination when adequate astronomy filters are inserted as excitatory and suppression filters in the illuminating and imaging light path. In all variants, transmission bands can be modulated by transmission shift.
Optical design of an in vivo laparoscopic lighting system
NASA Astrophysics Data System (ADS)
Liu, Xiaolong; Abdolmalaki, Reza Yazdanpanah; Mancini, Gregory J.; Tan, Jindong
2017-12-01
This paper proposes an in vivo laparoscopic lighting system design to address the illumination issues, namely poor lighting uniformity and low optical efficiency, existing in the state-of-the-art in vivo laparoscopic cameras. The transformable design of the laparoscopic lighting system is capable of carrying purposefully designed freeform optical lenses for achieving lighting performance with high illuminance uniformity and high optical efficiency in a desired target region. To design freeform optical lenses for extended light sources such as LEDs with Lambertian light intensity distributions, we present an effective and complete freeform optical design method. The procedures include (1) ray map computation by numerically solving a standard Monge-Ampere equation; (2) initial freeform optical surface construction by using Snell's law and a lens volume restriction; (3) correction of surface normal vectors due to accumulated errors from the initially constructed surfaces; and (4) feedback modification of the solution to deal with degraded illuminance uniformity caused by the extended sizes of the LEDs. We employed an optical design software package to evaluate the performance of our laparoscopic lighting system design. The simulation results show that our design achieves greater than 95% illuminance uniformity and greater than 89% optical efficiency (considering Fresnel losses) for illuminating the target surgical region.
Justification of Natural Lighting Management for Workplaces with Displays
NASA Astrophysics Data System (ADS)
Kudryashov, A. V.; Erunova, A. V.; Kalinina, A. S.
2017-11-01
The article is devoted to the study of the influence of the orientation of light apertures (windows) on the distribution of illumination in a room inside the workplaces equipped with displays. The measurements of natural light were carried out in two similar rooms, in the first room the windows are oriented to the north and in the second - to the south. The normative illumination value in a workplace equipped with a personal computer or display must be between 300 and 500 lux. However, during the daytime, the value of natural illumination at the workplace can exceed the normalized value by several times, and in the morning and evening hours is not sufficient. Such distribution of illumination involves the use a combined lighting control system (with daylight time control and switching on artificial lighting in the morning and evening hours). In the article it is justified that the orientation of the windows in the room does not have a significant effect on the distribution of illumination throughout the room which makes it possible not to take into account the restrictions concerning the orientation of the room’s light apertures when combined lighting control systems are used.
Adaptive illumination source for multispectral vision system applied to material discrimination
NASA Astrophysics Data System (ADS)
Conde, Olga M.; Cobo, Adolfo; Cantero, Paulino; Conde, David; Mirapeix, Jesús; Cubillas, Ana M.; López-Higuera, José M.
2008-04-01
A multispectral system based on a monochrome camera and an adaptive illumination source is presented in this paper. Its preliminary application is focused on material discrimination for food and beverage industries, where monochrome, color and infrared imaging have been successfully applied for this task. This work proposes a different approach, in which the relevant wavelengths for the required discrimination task are selected in advance using a Sequential Forward Floating Selection (SFFS) Algorithm. A light source, based on Light Emitting Diodes (LEDs) at these wavelengths is then used to sequentially illuminate the material under analysis, and the resulting images are captured by a CCD camera with spectral response in the entire range of the selected wavelengths. Finally, the several multispectral planes obtained are processed using a Spectral Angle Mapping (SAM) algorithm, whose output is the desired material classification. Among other advantages, this approach of controlled and specific illumination produces multispectral imaging with a simple monochrome camera, and cold illumination restricted to specific relevant wavelengths, which is desirable for the food and beverage industry. The proposed system has been tested with success for the automatic detection of foreign object in the tobacco processing industry.
Csete, Mária; Sipos, Áron; Najafi, Faraz; Hu, Xiaolong; Berggren, Karl K
2011-11-01
A finite-element method for calculating the illumination-dependence of absorption in three-dimensional nanostructures is presented based on the radio frequency module of the Comsol Multiphysics software package (Comsol AB). This method is capable of numerically determining the optical response and near-field distribution of subwavelength periodic structures as a function of illumination orientations specified by polar angle, φ, and azimuthal angle, γ. The method was applied to determine the illumination-angle-dependent absorptance in cavity-based superconducting-nanowire single-photon detector (SNSPD) designs. Niobium-nitride stripes based on dimensions of conventional SNSPDs and integrated with ~ quarter-wavelength hydrogen-silsesquioxane-filled nano-optical cavity and covered by a thin gold film acting as a reflector were illuminated from below by p-polarized light in this study. The numerical results were compared to results from complementary transfer-matrix-method calculations on composite layers made of analogous film-stacks. This comparison helped to uncover the optical phenomena contributing to the appearance of extrema in the optical response. This paper presents an approach to optimizing the absorptance of different sensing and detecting devices via simultaneous numerical optimization of the polar and azimuthal illumination angles. © 2011 Optical Society of America
NASA Technical Reports Server (NTRS)
Batson, Vernon M.; Robertson, James B.; Parrish, Russell V.
1990-01-01
The aircraft cockpit ambient lighting simulation system (ACALSS) has been developed to study display readability and associated pilot/vehicle performance effects in a part-task simulator cockpit. In the study reported here, the ACALSS was used to determine the illumination levels at which subjects lose the ability to maintain aircraft states when using three display technologies as display media for primary flight displays: a standard monochrome EL (electroluminescent) flat-panel, a laboratory-class monochrome CRT, and an enhanced-brightness EL flat-panel. The multivariate statistical technique of modified profile analysis was used to test for performance differences between display devices as functions of illumination levels. The standard monochrome EL flat-panel display began to washout after the 2500 foot-candle level of illumination. The monochrome CRT began to washout after the 5500 foot-candle level of illumination. No performance decrements by increased illumination up to the 12,000 foot-candle level were found for the enhanced-brightness EL flat-panel display. What was not anticipated was that half the subjects would subjectively prefer the CRT over the enhanced-brightness EL, even though their performance errors would have indicated the opposite.
Vinogradova, I A; Bukalev, A V; Zabezhinski, M A; Semenchenko, A V; Khavinson, V Kh; Anisimov, V N
2007-12-01
The effects of Ala-Glu-Asp-Gly peptide (Epithalon) on the life span and development of spontaneous tumors were studied in female rats exposed to standard, natural for North-Western Russia, and constant illumination. The mean life span of animals exposed to constant or natural illumination decreased by 13.5 and 25.5%, the maximum by 9 and 7 months, respectively, and spontaneous tumors developed much more rapidly than in animals living under conditions of the standard light regimen. Epithalon (0.1 microg daily 5 times a week from the age of 4 months) did not change the life span of rats living under conditions of standard day/night regimen, while in rats exposed to the natural and constant light it promoted prolongation of the maximum life span by 95 and 24 days, respectively. Epithalon prolonged the mean life span of the last 10% of rats exposed to natural and constant illumination, treated with Epithalon, by 137 and 43 days, respectively. This peptide exhibited virtually no effect on the development of spontaneous tumors in rats exposed to standard and constant illumination, but significantly inhibited their development in rats exposed to natural light.
Brain heating induced by near-infrared lasers during multiphoton microscopy
Ranganathan, Gayathri
2016-01-01
Two-photon imaging and optogenetic stimulation rely on high illumination powers, particularly for state-of-the-art applications that target deeper structures, achieve faster measurements, or probe larger brain areas. However, little information is available on heating and resulting damage induced by high-power illumination in the brain. In the current study we used thermocouple probes and quantum dot nanothermometers to measure temperature changes induced by two-photon microscopy in the neocortex of awake and anaesthetized mice. We characterized heating as a function of wavelength, exposure time, and distance from the center of illumination. Although total power is highest near the surface of the brain, heating was most severe hundreds of micrometers below the focal plane, due to heat dissipation through the cranial window. Continuous illumination of a 1-mm2 area produced a peak temperature increase of ∼1.8°C/100 mW. Continuous illumination with powers above 250 mW induced lasting damage, detected with immunohistochemistry against Iba1, glial fibrillary acidic protein, heat shock proteins, and activated caspase-3. Higher powers were usable in experiments with limited duty ratios, suggesting an approach to mitigate damage in high-power microscopy experiments. PMID:27281749
NASA Astrophysics Data System (ADS)
Adal, Kedir M.; van Etten, Peter G.; Martinez, Jose P.; Rouwen, Kenneth; Vermeer, Koenraad A.; van Vliet, Lucas J.
2017-03-01
Automated detection and quantification of spatio-temporal retinal changes is an important step to objectively assess disease progression and treatment effects for dynamic retinal diseases such as diabetic retinopathy (DR). However, detecting retinal changes caused by early DR lesions such as microaneurysms and dot hemorrhages from longitudinal pairs of fundus images is challenging due to intra and inter-image illumination variation between fundus images. This paper explores a method for automated detection of retinal changes from illumination normalized fundus images using a deep convolutional neural network (CNN), and compares its performance with two other CNNs trained separately on color and green channel fundus images. Illumination variation was addressed by correcting for the variability in the luminosity and contrast estimated from a large scale retinal regions. The CNN models were trained and evaluated on image patches extracted from a registered fundus image set collected from 51 diabetic eyes that were screened at two different time-points. The results show that using normalized images yield better performance than color and green channel images, suggesting that illumination normalization greatly facilitates CNNs to quickly and correctly learn distinctive local image features of DR related retinal changes.
Active polarization descattering.
Treibitz, Tali; Schechner, Yoav Y
2009-03-01
Vision in scattering media is important but challenging. Images suffer from poor visibility due to backscattering and attenuation. Most prior methods for scene recovery use active illumination scanners (structured and gated), which can be slow and cumbersome, while natural illumination is inapplicable to dark environments. The current paper addresses the need for a non-scanning recovery method, that uses active scene irradiance. We study the formation of images under widefield artificial illumination. Based on the formation model, the paper presents an approach for recovering the object signal. It also yields rough information about the 3D scene structure. The approach can work with compact, simple hardware, having active widefield, polychromatic polarized illumination. The camera is fitted with a polarization analyzer. Two frames of the scene are taken, with different states of the analyzer or polarizer. A recovery algorithm follows the acquisition. It allows both the backscatter and the object reflection to be partially polarized. It thus unifies and generalizes prior polarization-based methods, which had assumed exclusive polarization of either of these components. The approach is limited to an effective range, due to image noise and illumination falloff. Thus, the limits and noise sensitivity are analyzed. We demonstrate the approach in underwater field experiments.
NASA Astrophysics Data System (ADS)
Tang, Lan-Feng; Yu, Guang; Lu, Hai; Wu, Chen-Fei; Qian, Hui-Min; Zhou, Dong; Zhang, Rong; Zheng, You-Dou; Huang, Xiao-Ming
2015-08-01
The influence of white light illumination on the stability of an amorphous InGaZnO thin film transistor is investigated in this work. Under prolonged positive gate bias stress, the device illuminated by white light exhibits smaller positive threshold voltage shift than the device stressed under dark. There are simultaneous degradations of field-effect mobility for both stressed devices, which follows a similar trend to that of the threshold voltage shift. The reduced threshold voltage shift under illumination is explained by a competition between bias-induced interface carrier trapping effect and photon-induced carrier detrapping effect. It is further found that white light illumination could even excite and release trapped carriers originally exiting at the device interface before positive gate bias stress, so that the threshold voltage could recover to an even lower value than that in an equilibrium state. The effect of photo-excitation of oxygen vacancies within the a-IGZO film is also discussed. Project supported by the State Key Program for Basic Research of China (Grant Nos. 2011CB301900 and 2011CB922100) and the Priority Academic Program Development of Jiangsu Higher Education Institutions, China.
NASA Astrophysics Data System (ADS)
Kim, C. H.; Han, I. K.; Lee, J. I.; Kang, K. N.; Kwon, S. D.; Choe, B.; Park, H. L.; Her, J.; Lim, H.
1994-04-01
In this work, we investigated the effect of ultraviolet illumination, which is known to generate silicon dangling bonds, on the charge trapping behaviors, utilizing the constant capacitance technique in SiN(x)/InP structure where conventional PE CVD was used to form the SiN films on InP. We found different behaviors of this structure with ultraviolet illumination compared to the case of SiN(x)/Si structure. Both the Si-rich condition during PE CVD and ultraviolet illumination seem to not only increase the number of traps but also broaden the energy level of the traps in the insulator near the SiN(x)/InP interface. In all cases (N-rich, Si-rich, with and without ultraviolet illumination) the amphoteric nature of the traps has been observed, which is a characteristic of Si-dangling bonds. Also, the effect of ultraviolet photons on the interface of SiN(x)/InP, especially in correlation with the deficiency of phosphorus at the interface, is discussed considering the existence of net negative fixed charges at the interface.
Solid state light engines for bioanalytical instruments and biomedical devices
NASA Astrophysics Data System (ADS)
Jaffe, Claudia B.; Jaffe, Steven M.
2010-02-01
Lighting subsystems to drive 21st century bioanalysis and biomedical diagnostics face stringent requirements. Industrywide demands for speed, accuracy and portability mean illumination must be intense as well as spectrally pure, switchable, stable, durable and inexpensive. Ideally a common lighting solution could service these needs for numerous research and clinical applications. While this is a noble objective, the current technology of arc lamps, lasers, LEDs and most recently light pipes have intrinsic spectral and angular traits that make a common solution untenable. Clearly a hybrid solution is required to service the varied needs of the life sciences. Any solution begins with a critical understanding of the instrument architecture and specifications for illumination regarding power, illumination area, illumination and emission wavelengths and numerical aperture. Optimizing signal to noise requires careful optimization of these parameters within the additional constraints of instrument footprint and cost. Often the illumination design process is confined to maximizing signal to noise without the ability to adjust any of the above parameters. A hybrid solution leverages the best of the existing lighting technologies. This paper will review the design process for this highly constrained, but typical optical optimization scenario for numerous bioanalytical instruments and biomedical devices.
Instrumentation for low noise nanopore-based ionic current recording under laser illumination
NASA Astrophysics Data System (ADS)
Roelen, Zachary; Bustamante, José A.; Carlsen, Autumn; Baker-Murray, Aidan; Tabard-Cossa, Vincent
2018-01-01
We describe a nanopore-based optofluidic instrument capable of performing low-noise ionic current recordings of individual biomolecules under laser illumination. In such systems, simultaneous optical measurements generally introduce significant parasitic noise in the electrical signal, which can severely reduce the instrument sensitivity, critically hindering the monitoring of single-molecule events in the ionic current traces. Here, we present design rules and describe simple adjustments to the experimental setup to mitigate the different noise sources encountered when integrating optical components to an electrical nanopore system. In particular, we address the contributions to the electrical noise spectra from illuminating the nanopore during ionic current recording and mitigate those effects through control of the illumination source and the use of a PDMS layer on the SiNx membrane. We demonstrate the effectiveness of our noise minimization strategies by showing the detection of DNA translocation events during membrane illumination with a signal-to-noise ratio of ˜10 at 10 kHz bandwidth. The instrumental guidelines for noise minimization that we report are applicable to a wide range of nanopore-based optofluidic systems and offer the possibility of enhancing the quality of synchronous optical and electrical signals obtained during single-molecule nanopore-based analysis.
Optimizing countershading camouflage.
Cuthill, Innes C; Sanghera, N Simon; Penacchio, Olivier; Lovell, Paul George; Ruxton, Graeme D; Harris, Julie M
2016-11-15
Countershading, the widespread tendency of animals to be darker on the side that receives strongest illumination, has classically been explained as an adaptation for camouflage: obliterating cues to 3D shape and enhancing background matching. However, there have only been two quantitative tests of whether the patterns observed in different species match the optimal shading to obliterate 3D cues, and no tests of whether optimal countershading actually improves concealment or survival. We use a mathematical model of the light field to predict the optimal countershading for concealment that is specific to the light environment and then test this prediction with correspondingly patterned model "caterpillars" exposed to avian predation in the field. We show that the optimal countershading is strongly illumination-dependent. A relatively sharp transition in surface patterning from dark to light is only optimal under direct solar illumination; if there is diffuse illumination from cloudy skies or shade, the pattern provides no advantage over homogeneous background-matching coloration. Conversely, a smoother gradation between dark and light is optimal under cloudy skies or shade. The demonstration of these illumination-dependent effects of different countershading patterns on predation risk strongly supports the comparative evidence showing that the type of countershading varies with light environment.
Multispectral image fusion for illumination-invariant palmprint recognition
Zhang, Xinman; Xu, Xuebin; Shang, Dongpeng
2017-01-01
Multispectral palmprint recognition has shown broad prospects for personal identification due to its high accuracy and great stability. In this paper, we develop a novel illumination-invariant multispectral palmprint recognition method. To combine the information from multiple spectral bands, an image-level fusion framework is completed based on a fast and adaptive bidimensional empirical mode decomposition (FABEMD) and a weighted Fisher criterion. The FABEMD technique decomposes the multispectral images into their bidimensional intrinsic mode functions (BIMFs), on which an illumination compensation operation is performed. The weighted Fisher criterion is to construct the fusion coefficients at the decomposition level, making the images be separated correctly in the fusion space. The image fusion framework has shown strong robustness against illumination variation. In addition, a tensor-based extreme learning machine (TELM) mechanism is presented for feature extraction and classification of two-dimensional (2D) images. In general, this method has fast learning speed and satisfying recognition accuracy. Comprehensive experiments conducted on the PolyU multispectral palmprint database illustrate that the proposed method can achieve favorable results. For the testing under ideal illumination, the recognition accuracy is as high as 99.93%, and the result is 99.50% when the lighting condition is unsatisfied. PMID:28558064
Multispectral image fusion for illumination-invariant palmprint recognition.
Lu, Longbin; Zhang, Xinman; Xu, Xuebin; Shang, Dongpeng
2017-01-01
Multispectral palmprint recognition has shown broad prospects for personal identification due to its high accuracy and great stability. In this paper, we develop a novel illumination-invariant multispectral palmprint recognition method. To combine the information from multiple spectral bands, an image-level fusion framework is completed based on a fast and adaptive bidimensional empirical mode decomposition (FABEMD) and a weighted Fisher criterion. The FABEMD technique decomposes the multispectral images into their bidimensional intrinsic mode functions (BIMFs), on which an illumination compensation operation is performed. The weighted Fisher criterion is to construct the fusion coefficients at the decomposition level, making the images be separated correctly in the fusion space. The image fusion framework has shown strong robustness against illumination variation. In addition, a tensor-based extreme learning machine (TELM) mechanism is presented for feature extraction and classification of two-dimensional (2D) images. In general, this method has fast learning speed and satisfying recognition accuracy. Comprehensive experiments conducted on the PolyU multispectral palmprint database illustrate that the proposed method can achieve favorable results. For the testing under ideal illumination, the recognition accuracy is as high as 99.93%, and the result is 99.50% when the lighting condition is unsatisfied.
Noise tolerant illumination optimization applied to display devices
NASA Astrophysics Data System (ADS)
Cassarly, William J.; Irving, Bruce
2005-02-01
Display devices have historically been designed through an iterative process using numerous hardware prototypes. This process is effective but the number of iterations is limited by the time and cost to make the prototypes. In recent years, virtual prototyping using illumination software modeling tools has replaced many of the hardware prototypes. Typically, the designer specifies the design parameters, builds the software model, predicts the performance using a Monte Carlo simulation, and uses the performance results to repeat this process until an acceptable design is obtained. What is highly desired, and now possible, is to use illumination optimization to automate the design process. Illumination optimization provides the ability to explore a wider range of design options while also providing improved performance. Since Monte Carlo simulations are often used to calculate the system performance but those predictions have statistical uncertainty, the use of noise tolerant optimization algorithms is important. The use of noise tolerant illumination optimization is demonstrated by considering display device designs that extract light using 2D paint patterns as well as 3D textured surfaces. A hybrid optimization approach that combines a mesh feedback optimization with a classical optimizer is demonstrated. Displays with LED sources and cold cathode fluorescent lamps are considered.
Multiple speckle illumination for optical-resolution photoacoustic imaging
NASA Astrophysics Data System (ADS)
Poisson, Florian; Stasio, Nicolino; Moser, Christophe; Psaltis, Demetri; Bossy, Emmanuel
2017-03-01
Optical-resolution photoacoustic microscopy offers exquisite and specific contrast to optical absorption. Conventional approaches generally involves raster scanning a focused spot over the sample. Here, we demonstrate that a full-field illumination approach with multiple speckle illumination can also provide diffraction-limited optical-resolution photoacoustic images. Two different proof-of-concepts are demonstrated with micro-structured test samples. The first approach follows the principle of correlation/ghost imaging,1, 2 and is based on cross-correlating photoacoustic signals under multiple speckle illumination with known speckle patterns measured during a calibration step. The second approach is a speckle scanning microscopy technique, which adapts the technique proposed in fluorescence microscopy by Bertolotti and al.:3 in our work, spatially unresolved photoacoustic measurements are performed for various translations of unknown speckle patterns. A phase-retrieval algorithm is used to reconstruct the object from the knowledge of the modulus of its Fourier Transform yielded by the measurements. Because speckle patterns naturally appear in many various situations, including propagation through biological tissue or multi-mode fibers (for which focusing light is either very demanding if not impossible), speckle-illumination-based photoacoustic microscopy provides a powerful framework for the development of novel reconstruction approaches, well-suited to compressed sensing approaches.2
Lit appearance modeling of illumination systems
NASA Astrophysics Data System (ADS)
Koshel, R. John
2002-09-01
In illumination systems the look and feel are often more important than objective criterion, such as uniformity and efficiency. The reason for this is two fold: the lit appearance often sells an item and substantial variation in the illumination distribution (up to 50%) over a broad region is not noticeable to an observer. Therefore, subjective criterion, such as the lit appearance, typically plays a crucial role in the development of an illumination system. Additionally, by using computer models to ascertain the lit appearance before manufacture of the system, it allows the designer to modify the system while not demanding investment to produce prototypes. I discuss methods of determining the lit appearance for illumination systems. This modeling includes the inclusion of material and surface properties, such as surface finish, spectral transmission, and internal scattering; the response of the human eye; and the amount of rays that must be traced. By archiving the ray data, animations as a function of position and angle can be developed. Examples are developed to highlight the utility of this technique. These examples include taillights for the automotive industry and a backlit LCD screen for a laptop. Animations of these models demonstrate their luminance.
Compact, cost-effective and field-portable microscope prototype based on MISHELF microscopy
NASA Astrophysics Data System (ADS)
Sanz, Martín; Picazo-Bueno, José Ángel; Granero, Luis; García, Javier; Micó, Vicente
2017-02-01
We report on a reduced cost, portable and compact prototype design of lensless holographic microscope with an illumination/detection scheme based on wavelength multiplexing, working with single hologram acquisition and using a fast convergence algorithm for image processing. All together, MISHELF (initials coming from Multi-Illumination Single-Holographic-Exposure Lensless Fresnel) microscopy allows the recording of three Fresnel domain diffraction patterns in a single camera snap-shot incoming from illuminating the sample with three coherent lights at once. Previous implementations have proposed an illumination/detection procedure based on a tuned (illumination wavelengths centered at the maximum sensitivity of the camera detection channels) configuration but here we report on a detuned (non-centered ones) scheme resulting in prototype miniaturization and cost reduction. Thus, MISHELF microscopy in combination with a novel and fast iterative algorithm allows high-resolution (μm range) phase-retrieved (twin image elimination) quantitative phase imaging of dynamic events (video rate recording speed). The performance of this microscope prototype is validated through experiments using both amplitude (USAF resolution test) and complex (live swine sperm cells and flowing microbeads) samples. The proposed method becomes in an alternative instrument improving some capabilities of existing lensless microscopes.
Soft-light overhead illumination systems improve laparoscopic task performance.
Takai, Akihiro; Takada, Yasutsugu; Motomura, Hideki; Teramukai, Satoshi
2014-02-01
The aim of this study was to evaluate the impact of attached shadow cues for laparoscopic task performance. We developed a soft-light overhead illumination system (SOIS) that produced attached shadows on objects. We compared results using the SOIS with those using a conventional illumination system with regard to laparoscopic experience and laparoscope-to-target distances (LTDs). Forty-two medical students and 23 surgeons participated in the study. A peg transfer task (LTD, 120 mm) for students and surgeons, and a suture removal task (LTD, 30 mm) for students were performed. Illumination systems were randomly assigned to each task. Endpoints were: total number of peg transfers; percentage of peg-dropping errors; and total execution time for suture removal. After the task, participants filled out a questionnaire on their preference for a particular illumination system. Total number of peg transfers was greater with the SOIS for both students and surgeons. Percentage of peg-dropping errors for surgeons was lower with the SOIS. Total execution time for suture removal was shorter with the SOIS. Forty-five participants (69% in total) evaluated the SOIS for easier task performance. The present results confirm that the SOIS improves laparoscopic task performance, regardless of previous laparoscopic experience or LTD.
Categorical color constancy for simulated surfaces.
Olkkonen, Maria; Hansen, Thorsten; Gegenfurtner, Karl R
2009-11-12
Color constancy is the ability to perceive constant surface colors under varying lighting conditions. Color constancy has traditionally been investigated with asymmetric matching, where stimuli are matched over two different contexts, or with achromatic settings, where a stimulus is made to appear gray. These methods deliver accurate information on the transformations of single points of color space under illuminant changes, but can be cumbersome and unintuitive for observers. Color naming is a fast and intuitive alternative to matching, allowing data collection from a large portion of color space. We asked observers to name the colors of 469 Munsell surfaces with known reflectance spectra simulated under five different illuminants. Observers were generally as consistent in naming the colors of surfaces under different illuminants as they were naming the colors of the same surfaces over time. The transformations in category boundaries caused by illuminant changes were generally small and could be explained well with simple linear models. Finally, an analysis of the pattern of naming consistency across color space revealed that largely the same hues were named consistently across illuminants and across observers even after correcting for category size effects. This indicates a possible relationship between perceptual color constancy and the ability to consistently communicate colors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brendel, Moritz, E-mail: moritz.brendel@fbh-berlin.de; Helbling, Markus; Knigge, Andrea
2015-12-28
A comprehensive study on top- and bottom-illuminated Al{sub 0.5}Ga{sub 0.5}N/AlN metal-semiconductor-metal (MSM) photodetectors having different AlGaN absorber layer thickness is presented. The measured external quantum efficiency (EQE) shows pronounced threshold and saturation behavior as a function of applied bias voltage up to 50 V reaching about 50% for 0.1 μm and 67% for 0.5 μm thick absorber layers under bottom illumination. All experimental findings are in very good accordance with two-dimensional drift-diffusion modeling results. By taking into account macroscopic polarization effects in the hexagonal metal-polar +c-plane AlGaN/AlN heterostructures, new insights into the general device functionality of AlGaN-based MSM photodetectors are obtained. The observedmore » threshold/saturation behavior is caused by a bias-dependent extraction of photoexcited holes from the Al{sub 0.5}Ga{sub 0.5}N/AlN interface. While present under bottom illumination for any AlGaN layer thickness, under top illumination this mechanism influences the EQE-bias characteristics only for thin layers.« less
Compact, cost-effective and field-portable microscope prototype based on MISHELF microscopy
Sanz, Martín; Picazo-Bueno, José Ángel; Granero, Luis; García, Javier; Micó, Vicente
2017-01-01
We report on a reduced cost, portable and compact prototype design of lensless holographic microscope with an illumination/detection scheme based on wavelength multiplexing, working with single hologram acquisition and using a fast convergence algorithm for image processing. All together, MISHELF (initials coming from Multi-Illumination Single-Holographic-Exposure Lensless Fresnel) microscopy allows the recording of three Fresnel domain diffraction patterns in a single camera snap-shot incoming from illuminating the sample with three coherent lights at once. Previous implementations have proposed an illumination/detection procedure based on a tuned (illumination wavelengths centered at the maximum sensitivity of the camera detection channels) configuration but here we report on a detuned (non-centered ones) scheme resulting in prototype miniaturization and cost reduction. Thus, MISHELF microscopy in combination with a novel and fast iterative algorithm allows high-resolution (μm range) phase-retrieved (twin image elimination) quantitative phase imaging of dynamic events (video rate recording speed). The performance of this microscope prototype is validated through experiments using both amplitude (USAF resolution test) and complex (live swine sperm cells and flowing microbeads) samples. The proposed method becomes in an alternative instrument improving some capabilities of existing lensless microscopes. PMID:28233829
... BDSRA Store BDSRA Membership About BDSRA Chapter Locator Financials and Reporting History and Mission Illuminator Newsletter Our Staff and ... BDSRA Membership About BDSRA About BDSRA Chapter Locator Financials and Reporting History and Mission Illuminator Newsletter Our Staff and ...
Research notes : nighttime illumination of work zone flaggers.
DOT National Transportation Integrated Search
2006-05-01
As daytime traffic demands increase, nighttime construction and maintenance work is becoming more prevalent. The effective and efficient illumination of flaggers in these work zones is a significant concern . Insufficient light levels, disabling glar...
Circular, explosion-proof lamp provides uniform illumination
NASA Technical Reports Server (NTRS)
1966-01-01
Circular explosion-proof fluorescent lamp is fitted around a TV camera lens to provide shadowless illumination with a low radiant heat flux. The lamp is mounted in a transparent acrylic housing sealed with clear silicone rubber.
Quantitative phase retrieval with arbitrary pupil and illumination
Claus, Rene A.; Naulleau, Patrick P.; Neureuther, Andrew R.; ...
2015-10-02
We present a general algorithm for combining measurements taken under various illumination and imaging conditions to quantitatively extract the amplitude and phase of an object wave. The algorithm uses the weak object transfer function, which incorporates arbitrary pupil functions and partially coherent illumination. The approach is extended beyond the weak object regime using an iterative algorithm. Finally, we demonstrate the method on measurements of Extreme Ultraviolet Lithography (EUV) multilayer mask defects taken in an EUV zone plate microscope with both a standard zone plate lens and a zone plate implementing Zernike phase contrast.
Measuring Flow With Laser-Speckle Velocimetry
NASA Technical Reports Server (NTRS)
Smith, C. A.; Lourenco, L. M. M.; Krothapalli, A.
1988-01-01
Spatial resolution sufficient for calculation of vorticity.In laser-speckle velocimetry, pulsed or chopped laser beam expanded in one dimension by cylindrical lens to illuminate thin, fan-shaped region of flow measured. Flow seeded by small particles. Lens with optical axis perpendicular to illuminating beam forms image of illuminated particles on photographic plate. Speckle pattern of laser-illuminiated, seeded flow recorded in multiple-exposure photographs and processed to extract data on velocity field. Technique suited for study of vortical flows like those about helicopter rotor blades or airplane wings at high angles of attack.
Illuminating system and method for specialized and decorative lighting using liquid light guides
Zorn, C.J.; Kross, B.J.; Majewski, S.; Wojcik, R.F.
1998-08-25
The present invention comprises an illumination system for specialized decorative lighting including a light source, a flexible plastic tube sheath for distributing the light to a remote location, a transparent liquid core filling the tube that has an index of refraction greater than that of the plastic tube and an arrangement where light coupled from the light source is caused to leak from the liquid light guide at desired locations for the purposes of specialized lighting, such as underwater illumination in swimming pools. 5 figs.
Illuminating system and method for specialized and decorative lighting using liquid light guides
Zorn, Carl J.; Kross, Brian J.; Majewski, Stanislaw; Wojcik, Randolph F.
1998-01-01
The present invention comprises an illumination system for specialized decorative lighting including a light source, a flexible plastic tube sheath for distributing the light to a remote location, a transparent liquid core filling the tube that has an index of refraction greater than that of the plastic tube and an arrangement where light coupled from the light source is caused to leak from the liquid light guide at desired locations for the purposes of specialized lighting, such as underwater illumination in swimming pools.
Method and apparatus for determining the coordinates of an object
Pedersen, Paul S.
2002-01-01
A simplified method and related apparatus are described for determining the location of points on the surface of an object by varying, in accordance with a unique sequence, the intensity of each illuminated pixel directed to the object surface, and detecting at known detector pixel locations the intensity sequence of reflected illumination from the surface of the object whereby the identity and location of the originating illuminated pixel can be determined. The coordinates of points on the surface of the object are then determined by conventional triangulation methods.
2012-12-01
arrays. 3. Thermal and Active Illumination Power It is useful to note that a passive imager with 10 GHz band - width and a diffraction-limited 100 × 100...practical by the high brightness temperatures (1014–1018 K) that can be attained with narrow- band electronic illuminators. (4) Because of this high ...091604 (2012). 21. K. B. Cooper, R. J. Denglera, N. Llombartb, A. Talukdera, A. V. Panangadana, C. S . Peaya, I. Mehdia, and P. H. Siegel, “Fast, high
Mitigating illumination gradients in a SAR image based on the image data and antenna beam pattern
Doerry, Armin W.
2013-04-30
Illumination gradients in a synthetic aperture radar (SAR) image of a target can be mitigated by determining a correction for pixel values associated with the SAR image. This correction is determined based on information indicative of a beam pattern used by a SAR antenna apparatus to illuminate the target, and also based on the pixel values associated with the SAR image. The correction is applied to the pixel values associated with the SAR image to produce corrected pixel values that define a corrected SAR image.
RCS measurements, transformations, and comparisons under cylindrical and plane wave illumination
NASA Astrophysics Data System (ADS)
Vokura, V. J.; Balanis, Constantine A.; Birtcher, Craig R.
1994-03-01
Monostatic RCS measurements of a long bar (at X-band) and of a scale model aircraft (at C-band) were performed under the quasi-plane wave illumination produced by a dual parabolic-cylinder CATR. At Arizona State University's ElectroMagnetic Anechoic Chamber (EMAC) facility, these measurements were repeated under the cylindrical wave illumination produced by a March Microwave Single-Plane Collimating Range (SPCR). The SPRC measurements were corrected using corrected using the 'reference target method.' The corrected SPCR measurements are in good agreement with the CATR measurements.
Effect of Photogenerated Carriers on Ferroelectric Polarization Reversal
NASA Astrophysics Data System (ADS)
Weis, Martin; Li, Jun; Taguchi, Dai; Manaka, Takaaki; Iwamoto, Mitsumasa
2011-12-01
Three non-symmetric switching peaks were observed in current-voltage (J-V) characteristic of the pentacene/poly(vinylidene fluoride-trifluoroethylene) double-layer device. However, upon illumination only two symmetric switching peaks appeared during the same J-V measurement. The similar difference between dark and illumination were also obtained in capacitance-voltage characteristics. These results showed the strong influence of internal fields by photogenerated carriers, which modifies the polarization reversal process of ferroelectric layer. The gradual shift of the polarization reversal with increase of illumination intensity is assigned to the space-charge field of trapped electrons.
Numerical Simulation of Illumination and Thermal Conditions at the Lunar Poles Using LOLA DTMs
NASA Technical Reports Server (NTRS)
Glaser, P.; Glaser, D.; Oberst, J.; Neumann, G. A.; Mazarico, E.; Siegler, M. A.
2017-01-01
We are interested in illumination conditions and the temperature distribution within the upper two meters of regolith near the lunar poles. Here, areas exist receiving almost constant illumination near areas in permanent shadow, which were identified as potential exploration sites for future missions. For our study a numerical simulation of the illumination and thermal environment for lunar near-polar regions is needed. Our study is based on high-resolution, twenty meters per pixel and 400 x 400 km large polar Digital Terrain Models (DTMs), which were derived from Lunar Orbiter Laser Altimeter (LOLA) data. Illumination conditions were simulated by synthetically illuminating the LOLA DTMs using the horizon method considering the Sun as an extended source. We model polar illumination for the central 50 x 50 km subset and use it as an input at each time-step (2 h) to evaluate the heating of the lunar surface and subsequent conduction in the sub-surface. At surface level we balance the incoming insolation with the subsurface conduction and radiation into space, whereas in the sub-surface we consider conduction with an additional constant radiogenic heat source at the bottom of our two-meter layer. Density is modeled as depth-dependent, the specific heat parameter as temperature-dependent and the thermal conductivity as depth- and temperature-dependent. We implemented a fully implicit finite-volume method in space and backward Euler scheme in time to solve the one-dimensional heat equation at each pixel in our 50 x 50 km DTM. Due to the non-linear dependencies of the parameters mentioned above, Newton's method is employed as the non-linear solver together with the Gauss-Seidel method as the iterative linear solver in each Newton iteration. The software is written in OpenCL and runs in parallel on the GPU cores, which allows for fast computation of large areas and long time scales.
Sun, Steven; Francis, Jesse; Sapsford, Kim E.; Kostov, Yordan; Rasooly, Avraham
2010-01-01
A portable and rapid detection system for the activity analysis of Botulinum Neurotoxins (BoNT) is needed for food safety and bio-security applications. To improve BoNT activity detection, a previously designed portable charge-coupled device (CCD) based detector was modified and equipped with a higher intensity more versatile multi-wavelength spatial light-emitting diode (LED) illumination, a faster CCD detector and the capability to simultaneously detect 30 samples. A FITC/DABCYL Förster Resonance Energy Transfer (FRET)-labeled peptide substrate (SNAP-25), with BoNT-A target cleavage site sequence was used to measure BoNT-A light chain (LcA) activity through the FITC fluorescence increase that occurs upon peptide substrate cleavage. For fluorescence excitation, a multi-wavelength spatial LED illuminator was used and compared to our previous electroluminescent (EL) strips. The LED illuminator was equipped with blue, green, red and white LEDs, covering a spectrum of 450-680 nm (red 610-650 nm, green 492-550 nm, blue 450-495 nm, and white LED 440-680 nm). In terms of light intensity, the blue LED was found to be ~80 fold higher than the previously used blue EL strips. When measuring the activity of LcA the CCD detector limit of detection (LOD) was found to be 0.08 nM LcA for both the blue LED (2 s exposure) and the blue EL (which require ≥60 s exposure) while the limits of quantitation (LOQ) is about 1 nM. The LOD for white LED was higher at 1.4 nM while the white EL was not used for the assay due to a high variable background. Unlike the weaker intensity EL illumination the high intensity LED illumination enabled shorter exposure times and allowed multi-wavelength illumination without the need to physically change the excitation strip, thus making spectrum excitation of multiple fluorophores possible increasing the versatility of the detector platform for a variety of optical detection assays. PMID:20498728
NASA Astrophysics Data System (ADS)
Shi, Yi Fang; Park, Seung Hyo; Song, Taek Lyul
2017-12-01
The target tracking using multistatic passive radar in a digital audio/video broadcast (DAB/DVB) network with illuminators of opportunity faces two main challenges: the first challenge is that one has to solve the measurement-to-illuminator association ambiguity in addition to the conventional association ambiguity between the measurements and targets, which introduces a significantly complex three-dimensional (3-D) data association problem among the target-measurement illuminator, this is because all the illuminators transmit the same carrier frequency signals and signals transmitted by different illuminators but reflected via the same target become indistinguishable; the other challenge is that only the bistatic range and range-rate measurements are available while the angle information is unavailable or of very poor quality. In this paper, the authors propose a new target tracking algorithm directly in three-dimensional (3-D) Cartesian coordinates with the capability of track management using the probability of target existence as a track quality measure. The proposed algorithm is termed sequential processing-joint integrated probabilistic data association (SP-JIPDA), which applies the modified sequential processing technique to resolve the additional association ambiguity between measurements and illuminators. The SP-JIPDA algorithm sequentially operates the JIPDA tracker to update each track for each illuminator with all the measurements in the common measurement set at each time. For reasons of fair comparison, the existing modified joint probabilistic data association (MJPDA) algorithm that addresses the 3-D data association problem via "supertargets" using gate grouping and provides tracks directly in 3-D Cartesian coordinates, is enhanced by incorporating the probability of target existence as an effective track quality measure for track management. Both algorithms deal with nonlinear observations using the extended Kalman filtering. A simulation study is performed to verify the superiority of the proposed SP-JIPDA algorithm over the MJIPDA in this multistatic passive radar system.
Whitehead, Kathryn A; Smith, Lindsay A; Verran, Joanna
2008-09-30
Open food contact surfaces were subjected to organic soiling to provide a source for transfer of microbial cells. Rapid industrial methods used for the detection of residual cells and soil e.g. ATP (adenosine triphosphate) bioluminescence and an ultraviolet (UV) light detection method were assessed for their ability to detect organic soils, or organic soil-cell mix on surfaces. A range of soils (complex [meat extract, fish extract, cottage cheese extract]; oils [cholesterol, fish oil, mixed fatty acids]; proteins [bovine serum albumin, fish peptones casein]; carbohydrates [glycogen, starch, lactose]); was used. Under UV, oily soils, mixed fatty acids, cholesterol and casein were detected at low concentrations, with detection levels ranging from 1% to 0.001% for different substances. Glycogen was the most difficult substance to detect at lower concentrations. Using UV wavelength bands (lambda) of 330-380 nm, 510-560 nm and 590-650 nm, wavelength bands of 330-380 nm, illuminated most of the soils well, whilst the wavelength band of 510-560 nm illuminated the fish extract, cholesterol and fatty acids; the 590-650 nm wavelength band illuminated the lactose. Soils at all concentrations were detected by the ATP bioluminescence method; the complex soils gave the highest readings. When complex soils were combined with Listeria monocytogenes Scott A or a non-pathogenic Escherichia coli O157:H7, ATP measurements increased by 1-2 logs. For UV illumination, the L. monocytogenes and cheese combination was the most intensely illuminated, with E. coli and meat the least. UV illumination is a simple well established method for detecting food soil, with little change in findings when microorganisms are included. Performance can be enhanced in certain circumstances by altering the wavelength. ATP bioluminescence is a proven system for hygienic assessment being especially useful in the presence of microorganisms rather than organic soil alone.
NASA Astrophysics Data System (ADS)
Stork, David G.; Nagy, Gabor
2010-02-01
We explored the working methods of the Italian Baroque master Caravaggio through computer graphics reconstruction of his studio, with special focus on his use of lighting and illumination in The calling of St. Matthew. Although he surely took artistic liberties while constructing this and other works and did not strive to provide a "photographic" rendering of the tableau before him, there are nevertheless numerous visual clues to the likely studio conditions and working methods within the painting: the falloff of brightness along the rear wall, the relative brightness of the faces of figures, and the variation in sharpness of cast shadows (i.e., umbrae and penumbrae). We explored two studio lighting hypotheses: that the primary illumination was local (and hence artificial) and that it was distant solar. We find that the visual evidence can be consistent with local (artificial) illumination if Caravaggio painted his figures separately, adjusting the brightness on each to compensate for the falloff in illumination. Alternatively, the evidence is consistent with solar illumination only if the rear wall had particular reflectance properties, as described by a bi-directional reflectance distribution function, BRDF. (Ours is the first research applying computer graphics to the understanding of artists' praxis that models subtle reflectance properties of surfaces through BRDFs, a technique that may find use in studies of other artists.) A somewhat puzzling visual feature-unnoted in the scholarly literature-is the upward-slanting cast shadow in the upper-right corner of the painting. We found this shadow is naturally consistent with a local illuminant passing through a small window perpendicular to the viewer's line of sight, but could also be consistent with solar illumination if the shadow was due to a slanted, overhanging section of a roof outside the artist's studio. Our results place likely conditions upon any hypotheses concerning Caravaggio's working methods and point to new sources of evidence that could be confirmed or disconfirmed by future art historical research.
LRO-LAMP Observations of Illumination Conditions in the Lunar South Pole
NASA Astrophysics Data System (ADS)
Mandt, K.; Greathouse, T. K.; Retherford, K. D.; Mazarico, E.; Gladstone, R.; Liu, Y.; Hendrix, A.; Hurley, D.; Lemelin, M.; Patterson, G. W.; Bowman-Cisneros, E.
2016-12-01
The south pole of the Moon is an area of great interest for space exploration and scientific research, because many low-lying regions are permanently shaded while adjacent topographic highs experience near constant sunlight. The lack of direct sunlight in permanently shaded regions (PSRs) provides cold enough conditions for them to potentially trap and retain large quantities of volatiles in their soils, while the locations that receive extended periods of sunlight could provide a reliable source of solar energy and relatively stable temperature conditions. Illumination conditions at the lunar south pole vary diurnally and seasonally, but on different timescales than days and seasons on the Earth. The most important advancements in understanding illumination conditions at the poles are provided by topographic mapping and illumination modeling. These efforts have provided estimates of the extent of PSRs and the percent of time that sunlit peaks are illuminated. They also help to constrain the thermal balance of the PSRs based on other sources of illumination. However, comparing model results with spacecraft observations can help to validate the models and provides ground truth for planning future exploration efforts. We have developed a new method for observing illumination conditions at the south pole using data taken by the LRO Lyman Alpha Mapping Project (LAMP), a far ultraviolet (FUV) imaging spectrograph. LAMP produces maps of the albedo of the upper 25-100 nm of lunar regolith using measurements of the brightness of reflected light relative to known light sources in daytime and nighttime conditions. Nighttime observations have been used previously to determine the abundance of surface frost within the PSRs and the surface porosity of regolith within the PSRs. The maps that have been used for these studies excluded scattered sunlight by restricting observations to nighttime conditions when the solar zenith angle is greater than 91°. However, by producing maps of the PSRs using data that was excluded from these previous studies we are able to observe scattering of far-UV sunlight at night within the PSRs.
Analysis of Simulated Temporal Illumination at the Lunar PSRs
NASA Astrophysics Data System (ADS)
Thompson, T. J.; Mahanti, P.
2018-04-01
Illumination on the Moon is modeled temporally for permanently shadowed regions to lighting trends. Crater topography is used to generate viewfactor maps, which show which areas contribute most to scattered light into the primary shadows.
Illuminating NCTM's "Principles and Standards for School Mathematics."
ERIC Educational Resources Information Center
Keller, Brian A.; Hart, Eric W.; Martin, W. Gary
2001-01-01
Describes electronic resources designed to illuminate the National Council of Teachers of Mathematics' (NCTM) "Principles and Standards for School Mathematics". Provides a vehicle for further discussion of the vision put forth in the Standards. (Author/MM)
SEASAT: A satellite scatterometer illumination times of selected in situ sites
NASA Technical Reports Server (NTRS)
Schroeder, L. C.; Goodridge, D. R.; Boberly, J. C.; Hughes, J. K.; Sweet, J. L.
1982-01-01
A list of times that the SEASAT A Satellite Scatterometer (SASS) illuminated from directly above or directly abeam, selected surface sites where in situ winds were measured is provided. The list is ordered by the Greenwich Mean Time (GMT) of the midpoint of the illumination period (hit time) for a given surface site. The site identification, the orbit number and the direction from the subtrack in which the truth lies are provided. The accuracy of these times depends in part upon the ascending node times, which are estimated to be within +.1 sec, and on the illumination time relative to the ascending node, which is estimated to be within +6 seconds. The uncertainties in the times provided were judged to be sufficiently small to allow efficient and accurate extraction of SASS and in situ data at the selected surface sites. The list contains approximately six thousand hit times from 61 geographically dispersed sites.
NASA Astrophysics Data System (ADS)
Chiu, Y. C.; Zheng, Z. W.; Cheng, C. H.; Chen, P. C.; Yen, S. S.; Fan, C. C.; Hsu, H. H.; Kao, H. L.; Chang, C. Y.
2017-03-01
The electrical instability behaviors of amorphous indium-gallium-zinc oxide thin-film transistors with and without titanium sub-oxide passivation layer were investigated under light illumination in this study. For the unpassivated IGZO TFT device, in contrast with the dark case, a noticeable increase of the sub-threshold swing was observed when under the illumination environment, which can be attributed to the generation of ionized oxygen vacancies within the α-IGZO active layer by high energy photons. For the passivated TFT device, the much smaller SS of 70 mV/dec and high device mobility of >100 cm2/Vs at a drive voltage of 3 V with negligible degradation under light illumination are achieved due to the passivation effect of n-type titanium sub-oxide semiconductor, which may create potential application for high-performance display.
Light as an Energy Source in Continuous Cultures of Bacteriorhodopsin-Containing Halobacteria
Rodriguez-Valera, F.; Nieto, J. J.; Ruiz-Berraquero, F.
1983-01-01
The role of light as an energy source for slightly aereated cultures of halobacteria was studied, using continuous cultures with low nutrient concentrations and a low oxygen supply. A series of experiments were carried out with non-illuminated and differently illuminated cultures and with different oxygen transfer rates. Under low oxygen availability, light proved to be a decisively important energy source that allowed the populations to reach higher growth rates and much higher population densities. Oxygen influenced the growth over only a minimal level, below which neither the illuminated nor the dark cultures were affected by the oxygen transfer rate. From these results, it appears that the bacteriorhodopsin-mediated energy supply could have a very important role for the ecology of halobacteria in their microaerophilic habitats. In the illuminated cultures, cells that originated purple colonies on plates appeared. These cells, which could be bacteriorhodopsin-constitutive mutants, are now being studied. PMID:16346250
Thermal blinding of gated detectors in quantum cryptography.
Lydersen, Lars; Wiechers, Carlos; Wittmann, Christoffer; Elser, Dominique; Skaar, Johannes; Makarov, Vadim
2010-12-20
It has previously been shown that the gated detectors of two commercially available quantum key distribution (QKD) systems are blindable and controllable by an eavesdropper using continuous-wave illumination and short bright trigger pulses, manipulating voltages in the circuit [Nat. Photonics 4, 686 (2010)]. This allows for an attack eavesdropping the full raw and secret key without increasing the quantum bit error rate (QBER). Here we show how thermal effects in detectors under bright illumination can lead to the same outcome. We demonstrate that the detectors in a commercial QKD system Clavis2 can be blinded by heating the avalanche photo diodes (APDs) using bright illumination, so-called thermal blinding. Further, the detectors can be triggered using short bright pulses once they are blind. For systems with pauses between packet transmission such as the plug-and-play systems, thermal inertia enables Eve to apply the bright blinding illumination before eavesdropping, making her more difficult to catch.
NASA Astrophysics Data System (ADS)
Bruns, Thomas; Schickinger, Sarah; Wittig, Rainer; Schneckenburger, Herbert
2012-10-01
A device for selective plane illumination microscopy (SPIM) of three-dimensional multicellular spheroids, in culture medium under stationary or microfluidic conditions, is described. Cell spheroids are located in a micro-capillary and a light sheet, for illumination, is generated in an optical setup adapted to a conventional inverse microscope. Layers of the sample, of about 10 μm or less in diameter, are, thus, illuminated selectively and imaged by high resolution fluorescence microscopy. SPIM is operated at low light exposure even if a larger number of layers is imaged and is easily combined with laser scanning microscopy. Chinese hamster ovary cells expressing a membrane-associated green fluorescent protein are used for preliminary tests, and the uptake of the fluorescent marker, acridine orange via a microfluidic system, is visualized to demonstrate its potential in cancer research such as for the detection of cellular responses to anticancer drugs.
NASA Astrophysics Data System (ADS)
Yu, Kyeong Min; Moon, Hye Ji; Ryu, Min Ki; Cho, Kyoung Ik; Yun, Eui-Jung; Bae, Byung Seong
2012-09-01
Under white light illumination, amorphous indium-gallium-zinc oxide (a-IGZO)-based thin-film transistors (TFTs) showed a large negative shift of threshold voltage of more than -15 V depending on the process conditions. We investigated the influences of both gate bias and white light illumination on device properties of IGZO-based TFTs untreated and treated with high-energy electron beam irradiation (HEEBI). The TFTs were treated with HEEBI in air at room temperature (RT), electron beam energy of 0.8 MeV, and a dose of 1×1014 electrons/cm2. The HEEBI-treated TFTs showed an improved stability under negative bias illumination stress (NBIS) and positive bias illumination stress (PBIS) compared with non-HEEBI-treated TFTs, suggesting that the acceptor-like defects might be generated by HEEBI treatment near the valence band edge.
Cole, Brian; Goldberg, Lew; King, Vernon; Leach, Jeff
2010-04-26
UV illumination of a lithium niobate Q-switch was demonstrated as an effective means to eliminate a loss in hold-off and associated prelasing that occurs under cold temperature operation of Q-switched lasers. This degradation occurs due to the pyroelectric effect, where an accumulation of charge on crystal faces results in a reduction in the Q-switch hold-off and a spatially variable loss of the Q-switch in its high-transmission state, both resulting in lowering of the maximum Q-switched pulse energy. With UV illumination, the resulting creation of photo-generated carriers was shown to be effective in eliminating both of these effects. A Q-switched Nd:YAG laser utilizing UV-illuminated LiNbO(3) was shown to operate under cold temperatures without prelasing or spatially variable loss.
Optoelectrofluidic field separation based on light-intensity gradients
Lee, Sanghyun; Park, Hyun Jin; Yoon, Jin Sung; Kang, Kwan Hyoung
2010-01-01
Optoelectrofluidic field separation (OEFS) of particles under light -intensity gradient (LIG) is reported, where the LIG illumination on the photoconductive layer converts the short-ranged dielectrophoresis (DEP) force to the long-ranged one. The long-ranged DEP force can compete with the hydrodynamic force by alternating current electro-osmosis (ACEO) over the entire illumination area for realizing effective field separation of particles. In the OEFS system, the codirectional illumination and observation induce the levitation effect, compensating the attenuation of the DEP force under LIG illumination by slightly floating particles from the surface. Results of the field separation and concentration of diverse particle pairs (0.82–16 μm) are well demonstrated, and conditions determining the critical radius and effective particle manipulation are discussed. The OEFS with codirectional LIG strategy could be a promising particle manipulation method in many applications where a rapid manipulation of biological cells and particles over the entire working area are of interest. PMID:20697461
Optoelectrofluidic field separation based on light-intensity gradients.
Lee, Sanghyun; Park, Hyun Jin; Yoon, Jin Sung; Kang, Kwan Hyoung
2010-07-14
Optoelectrofluidic field separation (OEFS) of particles under light -intensity gradient (LIG) is reported, where the LIG illumination on the photoconductive layer converts the short-ranged dielectrophoresis (DEP) force to the long-ranged one. The long-ranged DEP force can compete with the hydrodynamic force by alternating current electro-osmosis (ACEO) over the entire illumination area for realizing effective field separation of particles. In the OEFS system, the codirectional illumination and observation induce the levitation effect, compensating the attenuation of the DEP force under LIG illumination by slightly floating particles from the surface. Results of the field separation and concentration of diverse particle pairs (0.82-16 mum) are well demonstrated, and conditions determining the critical radius and effective particle manipulation are discussed. The OEFS with codirectional LIG strategy could be a promising particle manipulation method in many applications where a rapid manipulation of biological cells and particles over the entire working area are of interest.
Holographic photolysis of caged neurotransmitters
Lutz, Christoph; Otis, Thomas S.; DeSars, Vincent; Charpak, Serge; DiGregorio, David A.; Emiliani, Valentina
2009-01-01
Stimulation of light-sensitive chemical probes has become a powerful tool for the study of dynamic signaling processes in living tissue. Classically, this approach has been constrained by limitations of lens–based and point-scanning illumination systems. Here we describe a novel microscope configuration that incorporates a nematic liquid crystal spatial light modulator (LC-SLM) to generate holographic patterns of illumination. This microscope can produce illumination spots of variable size and number and patterns shaped to precisely match user-defined elements in a specimen. Using holographic illumination to photolyse caged glutamate in brain slices, we demonstrate that shaped excitation on segments of neuronal dendrites and simultaneous, multi-spot excitation of different dendrites enables precise spatial and rapid temporal control of glutamate receptor activation. By allowing the excitation volume shape to be tailored precisely, the holographic microscope provides an extremely flexible method for activation of various photosensitive proteins and small molecules. PMID:19160517
Backside-illuminated 6.6-μm pixel video-rate CCDs for scientific imaging applications
NASA Astrophysics Data System (ADS)
Tower, John R.; Levine, Peter A.; Hsueh, Fu-Lung; Patel, Vipulkumar; Swain, Pradyumna K.; Meray, Grazyna M.; Andrews, James T.; Dawson, Robin M.; Sudol, Thomas M.; Andreas, Robert
2000-05-01
A family of backside illuminated CCD imagers with 6.6 micrometers pixels has been developed. The imagers feature full 12 bit (> 4,000:1) dynamic range with measured noise floor of < 10 e RMS at 5 MHz clock rates, and measured full well capacity of > 50,000 e. The modulation transfer function performance is excellent, with measured MTF at Nyquist of 46% for 500 nm illumination. Three device types have been developed. The first device is a 1 K X 1 K full frame device with a single output port, which can be run as a 1 K X 512 frame transfer device. The second device is a 512 X 512 frame transfer device with a single output port. The third device is a 512 X 512 split frame transfer device with four output ports. All feature the high quantum efficiency afforded by backside illumination.
Tailoring Heterovalent Interface Formation with Light
Park, Kwangwook; Alberi, Kirstin
2017-08-17
Integrating different semiconductor materials into an epitaxial device structure offers additional degrees of freedom to select for optimal material properties in each layer. However, interface between materials with different valences (i.e. III-V, II-VI and IV semiconductors) can be difficult to form with high quality. Using ZnSe/GaAs as a model system, we explore the use of UV illumination during heterovalent interface growth by molecular beam epitaxy as a way to modify the interface properties. We find that UV illumination alters the mixture of chemical bonds at the interface, permitting the formation of Ga-Se bonds that help to passivate the underlying GaAsmore » layer. Illumination also helps to reduce defects in the ZnSe epilayer. Furthermore, these results suggest that moderate UV illumination during growth may be used as a way to improve the optical properties of both the GaAs and ZnSe layers on either side of the interface.« less
Miniature LED endoilluminators for vitreoretinal surgery
NASA Astrophysics Data System (ADS)
Hessling, M.; Koelbl, P. S.; Lingenfelder, C.; Koch, F.
2015-07-01
Two innovative approaches for intraocular illumination during vitreoretinal surgery by application of white LEDs are being developed. Both techniques are less harmful to the patient, more convenient for the surgeon and smaller and cheaper compared to conventional illumination by Xenon light sources and optical fibers. These two novel approaches are: I) The miniature LED chandelier endoilluminator consisting of a single white LED with a "light probe" on top of the LED housing that fits in a small incision in the wall of the eye. II) The alternative transscleral LED endoilluminator is integrated into an eye speculum that presses the flat LED top against the eye. The intraocular space is only illuminated by light transmitted through the sclera. In contrast to conventional illumination techniques for vitreoretinal surgery no incision is necessary. Both approaches are evaluated with regard to potential photochemical and thermal risks for the patient's retina and they are tested on porcine eyes.
Retinex based low-light image enhancement using guided filtering and variational framework
NASA Astrophysics Data System (ADS)
Zhang, Shi; Tang, Gui-jin; Liu, Xiao-hua; Luo, Su-huai; Wang, Da-dong
2018-03-01
A new image enhancement algorithm based on Retinex theory is proposed to solve the problem of bad visual effect of an image in low-light conditions. First, an image is converted from the RGB color space to the HSV color space to get the V channel. Next, the illuminations are respectively estimated by the guided filtering and the variational framework on the V channel and combined into a new illumination by average gradient. The new reflectance is calculated using V channel and the new illumination. Then a new V channel obtained by multiplying the new illumination and reflectance is processed with contrast limited adaptive histogram equalization (CLAHE). Finally, the new image in HSV space is converted back to RGB space to obtain the enhanced image. Experimental results show that the proposed method has better subjective quality and objective quality than existing methods.
Real-time traffic sign recognition based on a general purpose GPU and deep-learning
Hong, Yongwon; Choi, Yeongwoo; Byun, Hyeran
2017-01-01
We present a General Purpose Graphics Processing Unit (GPGPU) based real-time traffic sign detection and recognition method that is robust against illumination changes. There have been many approaches to traffic sign recognition in various research fields; however, previous approaches faced several limitations when under low illumination or wide variance of light conditions. To overcome these drawbacks and improve processing speeds, we propose a method that 1) is robust against illumination changes, 2) uses GPGPU-based real-time traffic sign detection, and 3) performs region detecting and recognition using a hierarchical model. This method produces stable results in low illumination environments. Both detection and hierarchical recognition are performed in real-time, and the proposed method achieves 0.97 F1-score on our collective dataset, which uses the Vienna convention traffic rules (Germany and South Korea). PMID:28264011
Effects of illumination on human nocturnal serum melatonin levels and performance
NASA Technical Reports Server (NTRS)
Dollins, A. B.; Lynch, H. J.; Wurtman, R. J.; Deng, M. H.; Lieberman, H. R.
1993-01-01
In humans, exposure to bright light at night suppresses the normal nocturnal elevation in circulating melatonin. Oral administration of pharmacological doses of melatonin during the day, when melatonin levels are normally minimal, induces fatigue. To examine the relationship between illumination, human pineal function, and behavior, we monitored the overnight serum melatonin profiles and behavioral performance of 24 healthy male subjects. On each of three separate occasions subjects participated in 13.5 h (1630-0800 h) testing sessions. Each subject was assigned to an individually illuminated workstation that was maintained throughout the night at an illumination level of approximately 300, 1500, or 3000 lux. Melatonin levels were significantly diminished by light treatment, F(2, 36) = 12.77, p < 0.001, in a dose-dependent manner. Performance on vigilance, reaction time, and other tasks deteriorated throughout the night, consistent with known circadian variations in these parameters, but independent of ambient light intensity and circulating melatonin levels.
Study on light and thermal energy of illumination device for plant factory design
NASA Astrophysics Data System (ADS)
Yoshida, A.; Moriuchi, K.; Ueda, Y.; Kinoshita, S.
2018-01-01
To investigate the effect of illumination devices on the yield of crops cultivated in a plant factory, it is necessary to measure the actual cultivation environmental factors related to the plant growth and understand the distribution ratio of light and thermal energy to the electrical energy injected into the illumination device. Based on cultivation results, we found that light intensity greatly affected the growth of plant weight. Regarding the selection of illumination device, its spectral components also affected the morphological change. Lighting experiments using a high frequency (Hf) fluorescent lamp and a light emitting diode (LED) bulb were performed. A certain difference was found in the distribution ratio of light energy to electrical energy between Hf and LED. It was showed that by placing the safety equipment or internal circuits outside the cultivated site, the air conditioning load could be reduced.
Choosing surgical lighting in the LED era.
Knulst, Arjan J; Stassen, Laurents P S; Grimbergen, Cornelis A; Dankelman, Jenny
2009-12-01
The aim of this study is to evaluate the illumination characteristics of LED lights objectively to ease the selection of surgical lighting. The illuminance distributions of 5 main and 4 auxiliary lights were measured in 8 clinically relevant scenarios. For each light and scenario, the maximum illuminance E(c) (klux) and the size of the light field d(10) (mm) were computed. The results showed: that large variations for both E(c) (25-160 klux) and d(10) (109-300 mm) existed; that using auxiliary lights reduced both E(c) and d(10) by up to 80% and 30%; that with segmented lights, uneven light distributions occurred; and that with colored LED lights shadow edges on the surgical field became colored. Objective illuminance measurements show a wide variation between lights and a superiority of main over auxiliary lights. Uneven light distributions and colored shadows indicate that LED lights still need to converge to an optimal design.
Design of a novel freeform lens for LED uniform illumination and conformal phosphor coating.
Hu, Run; Luo, Xiaobing; Zheng, Huai; Qin, Zong; Gan, Zhiqiang; Wu, Bulong; Liu, Sheng
2012-06-18
A conformal phosphor coating can realize a phosphor layer with uniform thickness, which could enhance the angular color uniformity (ACU) of light-emitting diode (LED) packaging. In this study, a novel freeform lens was designed for simultaneous realization of LED uniform illumination and conformal phosphor coating. The detailed algorithm of the design method, which involves an extended light source and double refractions, was presented. The packaging configuration of the LED modules and the modeling of the light-conversion process were also presented. Monte Carlo ray-tracing simulations were conducted to validate the design method by comparisons with a conventional freeform lens. It is demonstrated that for the LED module with the present freeform lens, the illumination uniformity and ACU was 0.89 and 0.9283, respectively. The present freeform lens can realize equivalent illumination uniformity, but the angular color uniformity can be enhanced by 282.3% when compared with the conventional freeform lens.
Digital micromirror device based ophthalmoscope with concentric circle scanning.
Damodaran, Mathi; Vienola, Kari V; Braaf, Boy; Vermeer, Koenraad A; de Boer, Johannes F
2017-05-01
Retinal imaging is demonstrated using a novel scanning light ophthalmoscope based on a digital micromirror device with 810 nm illumination. Concentric circles were used as scan patterns, which facilitated fixation by a human subject for imaging. An annular illumination was implemented in the system to reduce the background caused by corneal reflections and thereby to enhance the signal-to-noise ratio. A 1.9-fold increase in the signal-to-noise ratio was found by using an annular illumination aperture compared to a circular illumination aperture, resulting in a 5-fold increase in imaging speed and a better signal-to-noise ratio compared to our previous system. We tested the imaging performance of our system by performing non-mydriatic imaging on two subjects at a speed of 7 Hz with a maximum 20° (diameter) field of view. The images were shot noise limited and clearly show various anatomical features of the retina with high contrast.
Digital micromirror device based ophthalmoscope with concentric circle scanning
Damodaran, Mathi; Vienola, Kari V.; Braaf, Boy; Vermeer, Koenraad A.; de Boer, Johannes F.
2017-01-01
Retinal imaging is demonstrated using a novel scanning light ophthalmoscope based on a digital micromirror device with 810 nm illumination. Concentric circles were used as scan patterns, which facilitated fixation by a human subject for imaging. An annular illumination was implemented in the system to reduce the background caused by corneal reflections and thereby to enhance the signal-to-noise ratio. A 1.9-fold increase in the signal-to-noise ratio was found by using an annular illumination aperture compared to a circular illumination aperture, resulting in a 5-fold increase in imaging speed and a better signal-to-noise ratio compared to our previous system. We tested the imaging performance of our system by performing non-mydriatic imaging on two subjects at a speed of 7 Hz with a maximum 20° (diameter) field of view. The images were shot noise limited and clearly show various anatomical features of the retina with high contrast. PMID:28663905
Apparatus for generating partially coherent radiation
Naulleau, Patrick P.
2004-09-28
The effective coherence of an undulator beamline can be tailored to projection lithography requirements by using a simple single moving element and a simple stationary low-cost spherical mirror. The invention is particularly suited for use in an illuminator device for an optical image processing system requiring partially coherent illumination. The illuminator includes: (i) source of coherent or partially coherent radiation which has an intrinsic coherence that is higher than the desired coherence; (ii) a reflective surface that receives incident radiation from said source; (iii) means for moving the reflective surface through a desired range of angles in two dimensions wherein the rate of the motion is fast relative to integration time of said image processing system; and (iv) a condenser optic that re-images the moving reflective surface to the entrance plane of said image processing system, thereby, making the illumination spot in said entrance plane essentially stationary.
Holographic illuminator for synchrotron-based projection lithography systems
Naulleau, Patrick P.
2005-08-09
The effective coherence of a synchrotron beam line can be tailored to projection lithography requirements by employing a moving holographic diffuser and a stationary low-cost spherical mirror. The invention is particularly suited for use in an illuminator device for an optical image processing system requiring partially coherent illumination. The illuminator includes: (1) a synchrotron source of coherent or partially coherent radiation which has an intrinsic coherence that is higher than the desired coherence, (2) a holographic diffuser having a surface that receives incident radiation from said source, (3) means for translating the surface of the holographic diffuser in two dimensions along a plane that is parallel to the surface of the holographic diffuser wherein the rate of the motion is fast relative to integration time of said image processing system; and (4) a condenser optic that re-images the surface of the holographic diffuser to the entrance plane of said image processing system.
Optimizing ultrafast illumination for multiphoton-excited fluorescence imaging
Stoltzfus, Caleb R.; Rebane, Aleksander
2016-01-01
We study the optimal conditions for high throughput two-photon excited fluorescence (2PEF) and three-photon excited fluorescence (3PEF) imaging using femtosecond lasers. We derive relations that allow maximization of the rate of imaging depending on the average power, pulse repetition rate, and noise characteristics of the laser, as well as on the size and structure of the sample. We perform our analysis using ~100 MHz, ~1 MHz and 1 kHz pulse rates and using both a tightly-focused illumination beam with diffraction-limited image resolution, as well loosely focused illumination with a relatively low image resolution, where the latter utilizes separate illumination and fluorescence detection beam paths. Our theoretical estimates agree with the experiments, which makes our approach especially useful for optimizing high throughput imaging of large samples with a field-of-view up to 10x10 cm2. PMID:27231620
Intense illumination in the morning hours improved mood and alertness but not mental performance.
Leichtfried, Veronika; Mair-Raggautz, Maria; Schaeffer, Viktoria; Hammerer-Lercher, Angelika; Mair, Gerald; Bartenbach, Christian; Canazei, Markus; Schobersberger, Wolfgang
2015-01-01
Cognitive performance and alertness are two determinants for work efficiency, varying throughout the day and depending on bright light. We conducted a prospective crossover study evaluating the impacts of exposure to an intense, early morning illumination on sustained attention, alertness, mood, and serum melatonin levels in 33 healthy individuals. Compared with a dim illumination, the intense illumination negatively impacted performance requiring sustained attention; however, it positively impacted subjective alertness and mood and had no impact on serum melatonin levels. These results suggest that brief exposure to bright light in the morning hours can improve subjective measures of mood and alertness, but can also have detrimental effects on mental performance as a result of visual distraction. Therefore, it is important that adequate lighting should correspond to both non-visual and visual demands. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Achieving uniform efficient illumination with multiple asymmetric compound parabolic luminaires
NASA Astrophysics Data System (ADS)
Gordon, Jeffrey M.; Kashin, Peter
1994-01-01
Luminaire designs based on multiple asymmetric nonimaging compound parabolic reflectors are proposed for 2-D illumination applications that require highly uniform far-field illuminance, while ensuring maximal lighting efficiency and sharp angular cutoffs. The new designs derive from recent advances in nonimaging secondary concentrators for line-focus solar collectors. The light source is not treated as a single entity, but rather is divided into two or more separate adjoining sources. An asymmetric compound parabolic luminaire is then designed around each half-source. Attaining sharp cutoffs requires relatively large reflectors. However, severe truncation of the reflectors renders these devices as compact as many conventional luminaires, at the penalty of a small fraction of the radiation being emitted outside the nominal cutoff. The configurations that maximize the uniformity of far-field illuminance offer significant improvements in flux homogeneity relative to alternative designs to date.
Achieving uniform efficient illumination with multiple asymmetric compound parabolic luminaires
NASA Astrophysics Data System (ADS)
Gordon, Jeffrey M.; Kashin, Peter
1993-11-01
Luminaire designs based on multiple asymmetric nonimaging compound parabolic reflectors are proposed for 2-D illumination applications that require highly uniform far-field illuminance, while insuring maximal lighting efficiency and sharp angular cutoffs. The new designs derive from recent advances in nonimaging secondary concentrators for line-focus solar collectors. The light source is not treated as a single entity, but rather is divided into two or more separate adjoining sources. An asymmetric Compound Parabolic Luminaire is then designed around each half-source. Attaining sharp cutoffs requires relatively large reflectors. However, severe truncation of the reflectors renders these devices as compact as many conventional luminaires, at the penalty of a small fraction of the radiation being emitted outside the nominal cutoff. The configurations that maximize the uniformity of far-field illumination offer significant improvements in flux homogeneity relative to alternative designs to date.
NASA Astrophysics Data System (ADS)
Li, Hao; Liu, Wenzhong; Zhang, Hao F.
2015-10-01
Rodent models are indispensable in studying various retinal diseases. Noninvasive, high-resolution retinal imaging of rodent models is highly desired for longitudinally investigating the pathogenesis and therapeutic strategies. However, due to severe aberrations, the retinal image quality in rodents can be much worse than that in humans. We numerically and experimentally investigated the influence of chromatic aberration and optical illumination bandwidth on retinal imaging. We confirmed that the rat retinal image quality decreased with increasing illumination bandwidth. We achieved the retinal image resolution of 10 μm using a 19 nm illumination bandwidth centered at 580 nm in a home-built fundus camera. Furthermore, we observed higher chromatic aberration in albino rat eyes than in pigmented rat eyes. This study provides a design guide for high-resolution fundus camera for rodents. Our method is also beneficial to dispersion compensation in multiwavelength retinal imaging applications.
NASA Astrophysics Data System (ADS)
Zonno, Irene; Martinez-Otero, Alberto; Hebig, Jan-Christoph; Kirchartz, Thomas
2017-03-01
The Mott-Schottky analysis in the dark is a frequently used method to determine the doping concentration of semiconductors from capacitance-voltage measurements, even for such complex systems as polymer:fullerene blends used for organic solar cells. While the analysis of capacitance-voltage measurements in the dark is relatively well established, the analysis of data taken under illumination is currently not fully understood. Here, we present experiments and simulations to show which physical mechanisms affect the Mott-Schottky analysis under illumination. We show that the mobility of the blend has a major influence on the shape of the capacitance-voltage curve and can be obtained from data taken under reverse bias. In addition, we show that the apparent shift of the built-in voltage observed previously can be explained by a shift of the onset of space-charge-limited collection with illumination intensity.
Broadband spectrally dynamic solid state illumination source
NASA Astrophysics Data System (ADS)
Nicol, David B.; Asghar, Ali; Gupta, Shalini; Kang, Hun; Pan, Ming; Strassburg, Martin; Summers, Chris; Ferguson, Ian T.
2006-06-01
Solid state lighting has done well recently in niche markets such as signage and displays, however, no available SSL technologies incorporate all the necessary attributes for general illumination. Development of a novel solid state general illumination source is discussed here. Two LEDs emitting at two distinct wavelengths can be monolithically grown and used to excite two or more phosphors with varied excitation spectra. The combined phosphorescence spectrum can then be controlled by adjusting the relative intensities of the two LED emissions. Preliminary phosphor analysis shows such a scheme to be viable for use in a spectrally dynamic broadband general illumination source. A tunnel junction is envisioned as a means of current spreading in a buried layer for three terminal operation. However, tunnel junction properties in GaN based materials are not well understood, and require further optimization to be practical devices. Preliminary results on GaN tunnel junctions are presented here as well.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shi, Zhemin; Department of Physical Electronics, Tokyo Institute of Technology, 2-12-1 O-okayama, Meguro-ku, Tokyo 152-8552; Taguchi, Dai
The details of turnover process of spontaneous polarization and associated carrier motions in indium-tin oxide/poly-(vinylidene-trifluoroethylene)/pentacene/Au capacitor were analyzed by coupling displacement current measurement (DCM) and electric-field-induced optical second-harmonic generation (EFISHG) measurement. A model was set up from DCM results to depict the relationship between electric field in semiconductor layer and applied external voltage, proving that photo illumination effect on the spontaneous polarization process lied in variation of semiconductor conductivity. The EFISHG measurement directly and selectively probed the electric field distribution in semiconductor layer, modifying the model and revealing detailed carrier behaviors involving photo illumination effect, dipole reversal, and interfacial chargingmore » in the device. A further decrease of DCM current in the low voltage region under illumination was found as the result of illumination effect, and the result was argued based on the changing of the total capacitance of the double-layer capacitors.« less
Weekenstroo, Harm H A; Cornelissen, Bart M W; Bernelot Moens, Hein J
2015-06-01
Nailfold capillaroscopy is a non-invasive and safe technique for the analysis of microangiopathologies. Imaging quality of widely used simple videomicroscopes is poor. The use of green illumination instead of the commonly used white light may improve contrast. The aim of the study was to compare the effect of green illumination with white illumination, regarding capillary density, the number of microangiopathologies, and sensitivity and specificity for systemic sclerosis. Five rheumatologists have evaluated 80 images; 40 images acquired with green light, and 40 images acquired with white light. A larger number of microangiopathologies were found in images acquired with green light than in images acquired with white light. This results in slightly higher sensitivity with green light in comparison with white light, without reducing the specificity. These findings suggest that green instead of white illumination may facilitate evaluation of capillaroscopic images obtained with a low-cost digital videomicroscope.
Apparatus and method for measuring single cell and sub-cellular photosynthetic efficiency
Davis, Ryan Wesley; Singh, Seema; Wu, Huawen
2013-07-09
Devices for measuring single cell changes in photosynthetic efficiency in algal aquaculture are disclosed that include a combination of modulated LED trans-illumination of different intensities with synchronized through objective laser illumination and confocal detection. Synchronization and intensity modulation of a dual illumination scheme were provided using a custom microcontroller for a laser beam block and constant current LED driver. Therefore, single whole cell photosynthetic efficiency, and subcellular (diffraction limited) photosynthetic efficiency measurement modes are permitted. Wide field rapid light scanning actinic illumination is provided for both by an intensity modulated 470 nm LED. For the whole cell photosynthetic efficiency measurement, the same LED provides saturating pulses for generating photosynthetic induction curves. For the subcellular photosynthetic efficiency measurement, a switched through objective 488 nm laser provides saturating pulses for generating photosynthetic induction curves. A second near IR LED is employed to generate dark adapted states in the system under study.
The evolution of structured illumination microscopy in studies of HIV.
Marno, Kelly; Al'Zoubi, Lara; Pearson, Matthew; Posch, Markus; McKnight, Áine; Wheeler, Ann P
2015-10-15
The resolution limit of conventional light microscopy has proven to be limiting for many biological structures such as viruses including Human immunodeficiency virus (HIV). Individual HIV virions are impossible to study using confocal microscopy as they are well below the 200 nm resolution limit of conventional light microscopes. Structured illumination microscopy (SIM) allows a twofold enhancement in image resolution compared to standard widefield illumination and so provides an excellent tool for study of HIV. Viral capsids (CAs) vary between 110 and 146 nm so this study challenges the performance of SIM microscopes. SIM microscopy was first developed in 2000, commercialised in 2007 and rapidly developed. Here we present the changes in capabilities of the SIM microscopes for study of HIV localisation as the instrumentation for structured illumination microscopy has evolved over the past 8 years. Copyright © 2015. Published by Elsevier Inc.
Re-identification of persons in multi-camera surveillance under varying viewpoints and illumination
NASA Astrophysics Data System (ADS)
Bouma, Henri; Borsboom, Sander; den Hollander, Richard J. M.; Landsmeer, Sander H.; Worring, Marcel
2012-06-01
The capability to track individuals in CCTV cameras is important for surveillance and forensics alike. However, it is laborious to do over multiple cameras. Therefore, an automated system is desirable. In literature several methods have been proposed, but their robustness against varying viewpoints and illumination is limited. Hence performance in realistic settings is also limited. In this paper, we present a novel method for the automatic re-identification of persons in video from surveillance cameras in a realistic setting. The method is computationally efficient, robust to a wide variety of viewpoints and illumination, simple to implement and it requires no training. We compare the performance of our method to several state-of-the-art methods on a publically available dataset that contains the variety of viewpoints and illumination to allow benchmarking. The results indicate that our method shows good performance and enables a human operator to track persons five times faster.
Simulated space environment tests on cadmium sulfide solar cells
NASA Technical Reports Server (NTRS)
Clarke, D. R.; Oman, H.
1971-01-01
Cadmium sulfide (Cu2s - CdS) solar cells were tested under simulated space environmental conditions. Some cells were thermally cycled with illumination from a Xenon-arc solar simulator. A cycle was one hour of illumination followed immediately with one-half hour of darkness. In the light, the cells reached an equilibrium temperature of 60 C (333 K) and in the dark the cell temperature dropped to -120 C (153 K). Other cells were constantly illuminated with a Xenon-arc solar simulator. The equilibrium temperature of these cells was 55 C (328 K). The black vacuum chamber walls were cooled with liquid nitrogen to simulate a space heat sink. Chamber pressure was maintained at 0.000001 torr or less. Almost all of the solar cells tested degraded in power when exposed to a simulated space environment of either thermal cycling or constant illumination. The cells tested the longest were exposed to 10.050 thermal cycles.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnstone, Peter; Jacobson, Arne; Mills, Evan
Creation of light for work, socializing, and general illumination is a fundamental application of technology around the world. For those who lack access to electricity, an emerging and diverse range of LED based lighting products hold promise for replacing and/or augmenting their current fuel-based lighting sources that are costly and dirty. Along with analysis of environmental factors, economic models for total cost-ofownership of LED lighting products are an important tool for studying the impacts of these products as they emerge in markets of developing countries. One important metric in those models is the minimum illuminance demanded by end-users for amore » given task before recharging the lamp or replacing batteries. It impacts the lighting service cost per unit time if charging is done with purchased electricity, batteries, or charging services. The concept is illustrated in figure 1: LED lighting products are generally brightest immediately after the battery is charged or replaced and the illuminance degrades as the battery is discharged. When a minimum threshold level of illuminance is reached, the operational time for the battery charge cycle is over. The cost to recharge depends on the method utilized; these include charging at a shop at a fixed price per charge, charging on personal grid connections, using solar chargers, and purchasing dry cell batteries. This Research Note reports on the observed"charge-triggering" illuminance level threshold for night market vendors who use LED lighting products to provide general and task oriented illumination. All the study participants charged with AC power, either at a fixed-price charge shop or with electricity at their home.« less
De novo post-illumination monoterpene burst in Quercus ilex (holm oak).
Srikanta Dani, K G; Marino, Giovanni; Taiti, Cosimo; Mancuso, Stefano; Atwell, Brian J; Loreto, Francesco; Centritto, Mauro
2017-02-01
Explicit proof for de novo origin of a rare post-illumination monoterpene burst and its consistency under low O 2 , shows interaction of photorespiration, photosynthesis, and isoprenoid biosynthesis during light-dark transitions. Quercus ilex L (holm oak) constitutively emits foliar monoterpenes in an isoprene-like fashion via the methyl erythritol phosphate (MEP) pathway located in chloroplasts. Isoprene-emitting plants are known to exhibit post-illumination isoprene burst, a transient emission of isoprene in darkness. An analogous post-illumination monoterpene burst (PiMB) had remained elusive and is reported here for the first time in Q. ilex. Using 13 CO 2 labelling, we show that PiMB is made from freshly fixed carbon. PiMB is rare at ambient (20%) O 2 , absent at high (50%) O 2 , and becomes consistent in leaves exposed to low (2%) O 2 . PiMB is stronger and occurs earlier at higher temperatures. We also show that primary and secondary post-illumination CO 2 bursts (PiCO 2 B) are sensitive to O 2 in Q. ilex. The primary photorespiratory PiCO 2 B is absent under both ambient and low O 2 , but is induced under high (>50%) O 2 , while the secondary PiCO 2 B (of unknown origin) is absent under ambient, but present at low and high O 2 . We propose that post-illumination recycling of photorespired CO 2 competes with the MEP pathway for photosynthetic carbon and energy, making PiMB rare under ambient O 2 and absent at high O 2 . PiMB becomes consistent when photorespiration is suppressed in Q. ilex.
Pipeline for illumination correction of images for high-throughput microscopy.
Singh, S; Bray, M-A; Jones, T R; Carpenter, A E
2014-12-01
The presence of systematic noise in images in high-throughput microscopy experiments can significantly impact the accuracy of downstream results. Among the most common sources of systematic noise is non-homogeneous illumination across the image field. This often adds an unacceptable level of noise, obscures true quantitative differences and precludes biological experiments that rely on accurate fluorescence intensity measurements. In this paper, we seek to quantify the improvement in the quality of high-content screen readouts due to software-based illumination correction. We present a straightforward illumination correction pipeline that has been used by our group across many experiments. We test the pipeline on real-world high-throughput image sets and evaluate the performance of the pipeline at two levels: (a) Z'-factor to evaluate the effect of the image correction on a univariate readout, representative of a typical high-content screen, and (b) classification accuracy on phenotypic signatures derived from the images, representative of an experiment involving more complex data mining. We find that applying the proposed post-hoc correction method improves performance in both experiments, even when illumination correction has already been applied using software associated with the instrument. To facilitate the ready application and future development of illumination correction methods, we have made our complete test data sets as well as open-source image analysis pipelines publicly available. This software-based solution has the potential to improve outcomes for a wide-variety of image-based HTS experiments. © 2014 The Authors. Journal of Microscopy published by John Wiley & Sons Ltd on behalf of Royal Microscopical Society.
Apparatus and method for generating partially coherent illumination for photolithography
Sweatt, W.C.
1999-07-06
The present invention relates an apparatus and method for creating a bright, uniform source of partially coherent radiation for illuminating a pattern, in order to replicate an image of said pattern with a high degree of acuity. The present invention introduces a novel scatter plate into the optical path of source light used for illuminating a replicated object. The scatter plate has been designed to interrupt a focused, incoming light beam by introducing between about 8 to 24 diffraction zones blazed onto the surface of the scatter plate which intercept the light and redirect it to a like number of different positions in the condenser entrance pupil each of which is determined by the relative orientation and the spatial frequency of the diffraction grating in each of the several zones. Light falling onto the scatter plate, therefore, generates a plurality of unphased sources of illumination as seen by the back half of the optical system. The system includes a high brightness source, such as a laser, creating light which is taken up by a beam forming optic which focuses the incoming light into a condenser which in turn, focuses light into a field lens creating Kohler illumination image of the source in a camera entrance pupil. The light passing through the field lens illuminates a mask which interrupts the source light as either a positive or negative image of the object to be replicated. Light passing by the mask is focused into the entrance pupil of the lithographic camera creating an image of the mask onto a receptive media. 7 figs.
Apparatus and method for generating partially coherent illumination for photolithography
Sweatt, William C.
1999-01-01
The present invention relates an apparatus and method for creating a bright, uniform source of partially coherent radiation for illuminating a pattern, in order to replicate an image of said pattern with a high degree of acuity. The present invention introduces a novel scatter plate into the optical path of source light used for illuminating a replicated object. The scatter plate has been designed to interrupt a focused, incoming light beam by introducing between about 8 to 24 diffraction zones blazed onto the surface of the scatter plate which intercept the light and redirect it to a like number of different positions in the condenser entrance pupil each of which is determined by the relative orientation and the spatial frequency of the diffraction grating in each of the several zones. Light falling onto the scatter plate, therefore, generates a plurality of unphased sources of illumination as seen by the back half of the optical system. The system includes a high brightness source, such as a laser, creating light which is taken up by a beam forming optic which focuses the incoming light into a condenser which in turn, focuses light into a field lens creating Kohler illumination image of the source in a camera entrance pupil. The light passing through the field lens illuminates a mask which interrupts the source light as either a positive or negative image of the object to be replicated. Light passing by the mask is focused into the entrance pupil of the lithographic camera creating an image of the mask onto a receptive media.
Consensual pupillary light response in the red-eared slider turtle (Trachemys scripta elegans).
Dearworth, James R; Sipe, Grayson O; Cooper, Lori J; Brune, Erin E; Boyd, Angela L; Riegel, Rhae A L
2010-03-17
Purpose of this study was to determine if the turtle has a consensual pupillary light response (cPLR), and if so, to compare it to its direct pupillary light response (dPLR). One eye was illuminated with different intensities of light over a four log range while keeping the other eye in darkness. In the eye directly illuminated, pupil diameter was reduced by as much as approximately 31%. In the eye not stimulated by light, pupil diameter was also reduced but less to approximately 11%. When compared to the directly illuminated eye, this generated a ratio, cPLR-dPLR, equal to 0.35. Ratio of slopes for log/linear fits to plots of pupil changes versus retinal irradiance for non-illuminated (-1.27) to illuminated (-3.94) eyes closely matched at 0.32. cPLR had time constants ranging from 0.60 to 1.20min; however, they were comparable and not statistically different from those of the dPLR, which ranged from 1.41 to 2.00min. Application of mydriatic drugs to the directly illuminated eye also supported presence of a cPLR. Drugs reduced pupil constriction by approximately 9% for the dPLR and slowed its time constant to 9.58min while simultaneous enhancing constriction by approximately 6% for the cPLR. Time constant for the cPLR at 1.75min, however, was not changed. Results support that turtle possesses a cPLR although less strong than its dPLR. Copyright 2010 Elsevier Ltd. All rights reserved.
Image correlation microscopy for uniform illumination.
Gaborski, T R; Sealander, M N; Ehrenberg, M; Waugh, R E; McGrath, J L
2010-01-01
Image cross-correlation microscopy is a technique that quantifies the motion of fluorescent features in an image by measuring the temporal autocorrelation function decay in a time-lapse image sequence. Image cross-correlation microscopy has traditionally employed laser-scanning microscopes because the technique emerged as an extension of laser-based fluorescence correlation spectroscopy. In this work, we show that image correlation can also be used to measure fluorescence dynamics in uniform illumination or wide-field imaging systems and we call our new approach uniform illumination image correlation microscopy. Wide-field microscopy is not only a simpler, less expensive imaging modality, but it offers the capability of greater temporal resolution over laser-scanning systems. In traditional laser-scanning image cross-correlation microscopy, lateral mobility is calculated from the temporal de-correlation of an image, where the characteristic length is the illuminating laser beam width. In wide-field microscopy, the diffusion length is defined by the feature size using the spatial autocorrelation function. Correlation function decay in time occurs as an object diffuses from its original position. We show that theoretical and simulated comparisons between Gaussian and uniform features indicate the temporal autocorrelation function depends strongly on particle size and not particle shape. In this report, we establish the relationships between the spatial autocorrelation function feature size, temporal autocorrelation function characteristic time and the diffusion coefficient for uniform illumination image correlation microscopy using analytical, Monte Carlo and experimental validation with particle tracking algorithms. Additionally, we demonstrate uniform illumination image correlation microscopy analysis of adhesion molecule domain aggregation and diffusion on the surface of human neutrophils.
Kim, Jaejin; Hwang, Jinyoung; Woo, Young-Ah; Chung, Hoeil
2016-11-30
To investigate Raman spectral features of a coated biconvex tablet under variation of its orientation respective to laser illumination, spectra of the tablet were collected by illuminating laser on 12 different locations on the tablet with 3 different illumination angles of 45, 75 and 90°. The spectral variations were more substantial when the tablet faces with engraved letters and greater surface curvature were measured, since the sampled volume of coating relative to that of a core tablet changed significantly under these circumstances as the illumination angle varied. The preliminary examination confirmed that the acquisition of tablet-representative spectra was the requisite for reliable measurement of coating thickness. Then, to mimic real monitoring of coating process, Raman spectra were directly collected on a packing of 30 tablets with repetition of random tablet packing up to 15 times and univariate models utilizing the intensity of coating peak at 638cm -1 were developed using the cumulatively averaged spectra with an average weight of the 30 tablets as a reference. To acquire less tablet orientation-sensitive spectra, a wide area illumination (WAI) scheme providing a large sampling area (28.3mm 2 ) on a tablet with a long focal length (∼25cm) was employed. The averaging of the first to seventh spectra, equivalently utilizing more packing-representative spectra for quantitative analysis, made the measurement of nominal coating thickness of packed tablets accurate. Copyright © 2016 Elsevier B.V. All rights reserved.
Piper, Timm; Piper, Jörg
2012-04-01
Variable bright-darkfield contrast (VBDC) is a new technique in light microscopy which promises significant improvements in imaging of transparent colorless specimens especially when characterized by a high regional thickness and a complex three-dimensional architecture. By a particular light pathway, two brightfield- and darkfield-like partial images are simultaneously superimposed so that the brightfield-like absorption image based on the principal zeroth order maximum interferes with the darkfield-like reflection image which is based on the secondary maxima. The background brightness and character of the resulting image can be continuously modulated from a brightfield-dominated to a darkfield-dominated appearance. When the weighting of the dark- and brightfield components is balanced, medium background brightness will result showing the specimen in a phase- or interference contrast-like manner. Specimens can either be illuminated axially/concentrically or obliquely/eccentrically. In oblique illumination, the angle of incidence and grade of eccentricity can be continuously changed. The condenser aperture diaphragm can be used for improvements of the image quality in the same manner as usual in standard brightfield illumination. By this means, the illumination can be optimally adjusted to the specific properties of the specimen. In VBDC, the image contrast is higher than in normal brightfield illumination, blooming and scattering are lower than in standard darkfield examinations, and any haloing is significantly reduced or absent. Although axial resolution and depth of field are higher than in concurrent standard techniques, the lateral resolution is not visibly reduced. Three dimensional structures, reliefs and fine textures can be perceived in superior clarity. Copyright © 2011 Wiley-Liss, Inc.
Condenser-free contrast methods for transmitted-light microscopy
WEBB, K F
2015-01-01
Phase contrast microscopy allows the study of highly transparent yet detail-rich specimens by producing intensity contrast from phase objects within the sample. Presented here is a generalized phase contrast illumination schema in which condenser optics are entirely abrogated, yielding a condenser-free yet highly effective method of obtaining phase contrast in transmitted-light microscopy. A ring of light emitting diodes (LEDs) is positioned within the light-path such that observation of the objective back focal plane places the illuminating ring in appropriate conjunction with the phase ring. It is demonstrated that true Zernike phase contrast is obtained, whose geometry can be flexibly manipulated to provide an arbitrary working distance between illuminator and sample. Condenser-free phase contrast is demonstrated across a range of magnifications (4–100×), numerical apertures (0.13–1.65NA) and conventional phase positions. Also demonstrated is condenser-free darkfield microscopy as well as combinatorial contrast including Rheinberg illumination and simultaneous, colour-contrasted, brightfield, darkfield and Zernike phase contrast. By providing enhanced and arbitrary working space above the preparation, a range of concurrent imaging and electrophysiological techniques will be technically facilitated. Condenser-free phase contrast is demonstrated in conjunction with scanning ion conductance microscopy (SICM), using a notched ring to admit the scanned probe. The compact, versatile LED illumination schema will further lend itself to novel next-generation transmitted-light microscopy designs. The condenser-free illumination method, using rings of independent or radially-scanned emitters, may be exploited in future in other electromagnetic wavebands, including X-rays or the infrared. PMID:25226859
Color constancy for an unseen surface.
Norman, Liam J; Akins, Kathleen; Heywood, Charles A; Kentridge, Robert W
2014-12-01
The illumination of a scene strongly affects our perception of objects in that scene, e.g., the pages of a book illuminated by candlelight will appear quite yellow relative to other types of artificial illuminants. Yet at the same time, the reader still judges the pages as white, their surface color unaffected by the interplay of paper and illuminant. It has been shown empirically that we can indeed report two quite different interpretations of "color": one is dependent on the constant surface spectral reflectance of an object (surface color) and the other on the power of light of different wavelengths reflected from that object (reflected color). How then are these two representations related? The common view, dating from Aristotle, is that our experience of surface color is derived from reflected color or, in more familiar terms, that color perception follows from color sensation. By definition, color constancy requires that vision "discounts the illuminant"; thus, it seems reasonable that vision begins with the color of objects as they naively appear and that we infer from their appearances their surface color. Here, we question this classic view. We use metacontrast-masked priming and, by presenting the unseen prime and the visible mask under different illuminants, dissociate two ways in which the prime matched the mask: in surface color or in reflected color. We find that priming of the mask occurs when it matches the prime in surface color, not reflected color. It follows that color perception can arise without prior color sensation. Copyright © 2014 Elsevier Ltd. All rights reserved.
Reflectance, illumination, and appearance in color constancy
McCann, John J.; Parraman, Carinna; Rizzi, Alessandro
2013-01-01
We studied color constancy using a pair of identical 3-D Color Mondrian displays. We viewed one 3-D Mondrian in nearly uniform illumination, and the other in directional, nonuniform illumination. We used the three dimensional structures to modulate the light falling on the painted surfaces. The 3-D structures in the displays were a matching set of wooden blocks. Across Mondrian displays, each corresponding facet had the same paint on its surface. We used only 6 chromatic, and 5 achromatic paints applied to 104 block facets. The 3-D blocks add shadows and multiple reflections not found in flat Mondrians. Both 3-D Mondrians were viewed simultaneously, side-by-side. We used two techniques to measure correlation of appearance with surface reflectance. First, observers made magnitude estimates of changes in the appearances of identical reflectances. Second, an author painted a watercolor of the 3-D Mondrians. The watercolor's reflectances quantified the changes in appearances. While constancy generalizations about illumination and reflectance hold for flat Mondrians, they do not for 3-D Mondrians. A constant paint does not exhibit perfect color constancy, but rather shows significant shifts in lightness, hue and chroma in response to the structure in the nonuniform illumination. Color appearance depends on the spatial information in both the illumination and the reflectances of objects. The spatial information of the quanta catch from the array of retinal receptors generates sensations that have variable correlation with surface reflectance. Models of appearance in humans need to calculate the departures from perfect constancy measured here. This article provides a dataset of measurements of color appearances for computational models of sensation. PMID:24478738
Popova, Antoaneta V; Dobrev, Konstantin; Velitchkova, Maya; Ivanov, Alexander G
2018-05-03
The high-light-induced alterations in photosynthetic performance of photosystem II (PSII) and photosystem I (PSI) as well as effectiveness of dissipation of excessive absorbed light during illumination for different periods of time at room (22 °C) and low (8-10 °C) temperature of leaves of Arabidopsis thaliana, wt and lut2, were followed with the aim of unraveling the role of lutein in the process of photoinhibition. Photosynthetic parameters of PSII and PSI were determined on whole leaves by PAM fluorometer and oxygen evolving activity-by a Clark-type electrode. In thylakoid membranes, isolated from non-illuminated and illuminated for 4.5 h leaves of wt and lut2 the photochemical activity of PSII and PSI and energy interaction between the main pigment-protein complexes was determined. Results indicate that in non-illuminated leaves of lut2 the maximum rate of oxygen evolution and energy utilization in PSII is lower, excitation pressure of PSII is higher and cyclic electron transport around PSI is faster than in wt leaves. Under high-light illumination, lut2 leaves are more sensitive in respect to PSII performance and the extent of increase of excitation pressure of PSII, Φ NO , and cyclic electron transport around PSI are higher than in wt leaves, especially when illumination is performed at low temperature. Significant part of the excessive light energy is dissipated via mechanism, not dependent on ∆pH and to functioning of xanthophyll cycle in LHCII, operating more intensively in lut2 leaves.
A fast color image enhancement algorithm based on Max Intensity Channel
Sun, Wei; Han, Long; Guo, Baolong; Jia, Wenyan; Sun, Mingui
2014-01-01
In this paper, we extend image enhancement techniques based on the retinex theory imitating human visual perception of scenes containing high illumination variations. This extension achieves simultaneous dynamic range modification, color consistency, and lightness rendition without multi-scale Gaussian filtering which has a certain halo effect. The reflection component is analyzed based on the illumination and reflection imaging model. A new prior named Max Intensity Channel (MIC) is implemented assuming that the reflections of some points in the scene are very high in at least one color channel. Using this prior, the illumination of the scene is obtained directly by performing a gray-scale closing operation and a fast cross-bilateral filtering on the MIC of the input color image. Consequently, the reflection component of each RGB color channel can be determined from the illumination and reflection imaging model. The proposed algorithm estimates the illumination component which is relatively smooth and maintains the edge details in different regions. A satisfactory color rendition is achieved for a class of images that do not satisfy the gray-world assumption implicit to the theoretical foundation of the retinex. Experiments are carried out to compare the new method with several spatial and transform domain methods. Our results indicate that the new method is superior in enhancement applications, improves computation speed, and performs well for images with high illumination variations than other methods. Further comparisons of images from National Aeronautics and Space Administration and a wearable camera eButton have shown a high performance of the new method with better color restoration and preservation of image details. PMID:25110395
A fast color image enhancement algorithm based on Max Intensity Channel.
Sun, Wei; Han, Long; Guo, Baolong; Jia, Wenyan; Sun, Mingui
2014-03-30
In this paper, we extend image enhancement techniques based on the retinex theory imitating human visual perception of scenes containing high illumination variations. This extension achieves simultaneous dynamic range modification, color consistency, and lightness rendition without multi-scale Gaussian filtering which has a certain halo effect. The reflection component is analyzed based on the illumination and reflection imaging model. A new prior named Max Intensity Channel (MIC) is implemented assuming that the reflections of some points in the scene are very high in at least one color channel. Using this prior, the illumination of the scene is obtained directly by performing a gray-scale closing operation and a fast cross-bilateral filtering on the MIC of the input color image. Consequently, the reflection component of each RGB color channel can be determined from the illumination and reflection imaging model. The proposed algorithm estimates the illumination component which is relatively smooth and maintains the edge details in different regions. A satisfactory color rendition is achieved for a class of images that do not satisfy the gray-world assumption implicit to the theoretical foundation of the retinex. Experiments are carried out to compare the new method with several spatial and transform domain methods. Our results indicate that the new method is superior in enhancement applications, improves computation speed, and performs well for images with high illumination variations than other methods. Further comparisons of images from National Aeronautics and Space Administration and a wearable camera eButton have shown a high performance of the new method with better color restoration and preservation of image details.
A fast color image enhancement algorithm based on Max Intensity Channel
NASA Astrophysics Data System (ADS)
Sun, Wei; Han, Long; Guo, Baolong; Jia, Wenyan; Sun, Mingui
2014-03-01
In this paper, we extend image enhancement techniques based on the retinex theory imitating human visual perception of scenes containing high illumination variations. This extension achieves simultaneous dynamic range modification, color consistency, and lightness rendition without multi-scale Gaussian filtering which has a certain halo effect. The reflection component is analyzed based on the illumination and reflection imaging model. A new prior named Max Intensity Channel (MIC) is implemented assuming that the reflections of some points in the scene are very high in at least one color channel. Using this prior, the illumination of the scene is obtained directly by performing a gray-scale closing operation and a fast cross-bilateral filtering on the MIC of the input color image. Consequently, the reflection component of each RGB color channel can be determined from the illumination and reflection imaging model. The proposed algorithm estimates the illumination component which is relatively smooth and maintains the edge details in different regions. A satisfactory color rendition is achieved for a class of images that do not satisfy the gray-world assumption implicit to the theoretical foundation of the retinex. Experiments are carried out to compare the new method with several spatial and transform domain methods. Our results indicate that the new method is superior in enhancement applications, improves computation speed, and performs well for images with high illumination variations than other methods. Further comparisons of images from National Aeronautics and Space Administration and a wearable camera eButton have shown a high performance of the new method with better color restoration and preservation of image details.