Science.gov

Sample records for image plate quasi-laue

  1. A neutron image plate quasi-Laue diffractometer for protein crystallography

    SciTech Connect

    Cipriani, F.; Castagna, J.C.; Wilkinson, C.

    1994-12-31

    An instrument which is based on image plate technology has been constructed to perform cold neutron Laue crystallography on protein structures. The crystal is mounted at the center of a cylindrical detector which is 400mm long and has a circumference of 1000mm, with gadolinium oxide-containing image plates mounted on its exterior surface. Laue images registered on the plate are read out by rotating the drum and translating a laser read head parallel to the cylinder axis, giving a pixel size of 200{mu}m x 200{mu}m and a total read time of 5 minutes. Preliminary results indicate that it should be possible to obtain a complete data set from a protein crystal to atomic resolution in about two weeks.

  2. A Quasi-Laue Neutron Crystallographic Study of D-Xylose Isomerase

    NASA Technical Reports Server (NTRS)

    Meilleur, Flora; Snell, Edward H.; vanderWoerd, Mark; Judge, Russell A.; Myles, Dean A. A.

    2006-01-01

    Hydrogen atom location and hydrogen bonding interaction determination are often critical to explain enzymatic mechanism. Whilst it is difficult to determine the position of hydrogen atoms using X-ray crystallography even with subatomic (less than 1.0 Angstrom) resolution data available, neutron crystallography provides an experimental tool to directly localise hydrogeddeuteriwn atoms in biological macromolecules at resolution of 1.5-2.0 Angstroms. Linearisation and isomerisation of xylose at the active site of D-xylose isomerase rely upon a complex hydrogen transfer. Neutron quasi-Laue data were collected on Streptomyces rubiginosus D-xylose isomerase crystal using the LADI instrument at ILL with the objective to provide insight into the enzymatic mechanism (Myles et al. 1998). The neutron structure unambiguously reveals the protonation state of His 53 in the active site, identifying the model for the enzymatic pathway.

  3. A Quasi-Laue Neutron Crystallographic Study of D-Xylose Isomerase

    NASA Technical Reports Server (NTRS)

    Meilleur, Flora; Snell, Edward H.; vanderWoerd, Mark; Judge, Russell A.; Myles, Dean A. A.

    2006-01-01

    Hydrogen atom location and hydrogen bonding interaction determination are often critical to explain enzymatic mechanism. Whilst it is difficult to determine the position of hydrogen atoms using X-ray crystallography even with subatomic (less than 1.0 Angstrom) resolution data available, neutron crystallography provides an experimental tool to directly localise hydrogeddeuteriwn atoms in biological macromolecules at resolution of 1.5-2.0 Angstroms. Linearisation and isomerisation of xylose at the active site of D-xylose isomerase rely upon a complex hydrogen transfer. Neutron quasi-Laue data were collected on Streptomyces rubiginosus D-xylose isomerase crystal using the LADI instrument at ILL with the objective to provide insight into the enzymatic mechanism (Myles et al. 1998). The neutron structure unambiguously reveals the protonation state of His 53 in the active site, identifying the model for the enzymatic pathway.

  4. Pixelated neutron image plates

    NASA Astrophysics Data System (ADS)

    Schlapp, M.; Conrad, H.; von Seggern, H.

    2004-09-01

    Neutron image plates (NIPs) have found widespread application as neutron detectors for single-crystal and powder diffraction, small-angle scattering and tomography. After neutron exposure, the image plate can be read out by scanning with a laser. Commercially available NIPs consist of a powder mixture of BaFBr : Eu2+ and Gd2O3 dispersed in a polymer matrix and supported by a flexible polymer sheet. Since BaFBr : Eu2+ is an excellent x-ray storage phosphor, these NIPs are particularly sensitive to ggr-radiation, which is always present as a background radiation in neutron experiments. In this work we present results on NIPs consisting of KCl : Eu2+ and LiF that were fabricated into ceramic image plates in which the alkali halides act as a self-supporting matrix without the necessity for using a polymeric binder. An advantage of this type of NIP is the significantly reduced ggr-sensitivity. However, the much lower neutron absorption cross section of LiF compared with Gd2O3 demands a thicker image plate for obtaining comparable neutron absorption. The greater thickness of the NIP inevitably leads to a loss in spatial resolution of the image plate. However, this reduction in resolution can be restricted by a novel image plate concept in which a ceramic structure with square cells (referred to as a 'honeycomb') is embedded in the NIP, resulting in a pixelated image plate. In such a NIP the read-out light is confined to the particular illuminated pixel, decoupling the spatial resolution from the optical properties of the image plate material and morphology. In this work, a comparison of experimentally determined and simulated spatial resolutions of pixelated and unstructured image plates for a fixed read-out laser intensity is presented, as well as simulations of the properties of these NIPs at higher laser powers.

  5. Optimization of neutron imaging plate

    NASA Astrophysics Data System (ADS)

    Haga, Y. K.; Neriishi, K.; Takahashi, K.; Niimura, N.

    2002-07-01

    Considering the elementary processes of neutron detection occurring in the neutron imaging plate (NIP) has optimized the performance of NIP. For these processes, the color center creation efficiencies ( ɛcc values) have been experimentally determined with NIPs which have different mole fraction of photostimulated (PSL) material ( φPSL values) and different thickness ( t). The effectiveness of the optimization procedure has been demonstrated by the measurement of the neutron diffraction intensities from a hen egg-white lysozyme protein crystal.

  6. Microchannel Plate Imaging Detectors for the Ultraviolet

    NASA Technical Reports Server (NTRS)

    Siegmund, O. H. W.; Gummin, M. A.; Stock, J.; Marsh, D.

    1992-01-01

    There has been significant progress over the last few years in the development of technologies for microchannel plate imaging detectors in the Ultraviolet (UV). Areas where significant developments have occurred include enhancements of quantum detection efficiency through improved photocathodes, advances in microchannel plate performance characteristics, and development of high performance image readout techniques. The current developments in these areas are summarized, with their applications in astrophysical instrumentation.

  7. Microchannel Plate Imaging Detectors for the Ultraviolet

    NASA Technical Reports Server (NTRS)

    Siegmund, O. H. W.; Gummin, M. A.; Stock, J.; Marsh, D.

    1992-01-01

    There has been significant progress over the last few years in the development of technologies for microchannel plate imaging detectors in the Ultraviolet (UV). Areas where significant developments have occurred include enhancements of quantum detection efficiency through improved photocathodes, advances in microchannel plate performance characteristics, and development of high performance image readout techniques. The current developments in these areas are summarized, with their applications in astrophysical instrumentation.

  8. Image simulation for automatic license plate recognition

    NASA Astrophysics Data System (ADS)

    Bala, Raja; Zhao, Yonghui; Burry, Aaron; Kozitsky, Vladimir; Fillion, Claude; Saunders, Craig; Rodríguez-Serrano, José

    2012-01-01

    Automatic license plate recognition (ALPR) is an important capability for traffic surveillance applications, including toll monitoring and detection of different types of traffic violations. ALPR is a multi-stage process comprising plate localization, character segmentation, optical character recognition (OCR), and identification of originating jurisdiction (i.e. state or province). Training of an ALPR system for a new jurisdiction typically involves gathering vast amounts of license plate images and associated ground truth data, followed by iterative tuning and optimization of the ALPR algorithms. The substantial time and effort required to train and optimize the ALPR system can result in excessive operational cost and overhead. In this paper we propose a framework to create an artificial set of license plate images for accelerated training and optimization of ALPR algorithms. The framework comprises two steps: the synthesis of license plate images according to the design and layout for a jurisdiction of interest; and the modeling of imaging transformations and distortions typically encountered in the image capture process. Distortion parameters are estimated by measurements of real plate images. The simulation methodology is successfully demonstrated for training of OCR.

  9. Simulating radiographic inspections with imaging plates

    NASA Astrophysics Data System (ADS)

    Yao, Min; Duvauchelle, Philippe; Kaftandjian, Valérie; Petersol-Parmentier, Angéla; Schumm, Andreas

    2016-02-01

    Computed Radiography (CR) based on photostimulable imaging plates (IP) is a potential replacement technique for traditional silver film radiography. For the inspections of components with high wall thicknesses requiring higher energy sources, however, imaging plate performance suffers from a spectral response which is low for the higher energies and high in the energy range where scattered radiation is typically observed. For these applications, care must be taken to apply appropriate filtering. Simulation tools are expected to be helpful in determining optimal operating conditions. We present a computer model which combines deterministic and Monte Carlo methods to simulate the imaging chain, focusing in particular on the scanner model.

  10. Imaging plates calibration to X-rays

    NASA Astrophysics Data System (ADS)

    Curcio, A.; Andreoli, P.; Cipriani, M.; Claps, G.; Consoli, F.; Cristofari, G.; De Angelis, R.; Giulietti, D.; Ingenito, F.; Pacella, D.

    2016-05-01

    The growing interest for the Imaging Plates, due to their high sensitivity range and versatility, has induced, in the last years, to detailed characterizations of their response function in different energy ranges and kind of radiation/particles. A calibration of the Imaging Plates BAS-MS, BAS-SR, BAS-TR has been performed at the ENEA-Frascati labs by exploiting the X-ray fluorescence of different targets (Ca, Cu, Pb, Mo, I, Ta) and the radioactivity of a BaCs source, in order to cover the X-ray range between few keV to 80 keV.

  11. Spectral characterization of storage phosphor imaging plates

    SciTech Connect

    Deresch, A.; Jechow, M.; Gollwitzer, C.

    2014-02-18

    This work presents attenuation and sensitivity measurements of radiographic imaging plates (IPs) with quasimonoenergetic X-rays in the 8–60 kiloelectronvolt range. The measurements are used to validate theoretical predictions. A short overview of the theoretical model is given. The model can be used to describe the sensitivity of different detector types to a wide range of X-ray energies.

  12. Phase-Scrambler Plate Spreads Point Image

    NASA Technical Reports Server (NTRS)

    Edwards, Oliver J.; Arild, Tor

    1992-01-01

    Array of small prisms retrofit to imaging lens. Phase-scrambler plate essentially planar array of small prisms partitioning aperture of lens into many subapertures, and prism at each subaperture designed to divert relatively large diffraction spot formed by that subaperture to different, specific point on focal plane.

  13. Phase-Scrambler Plate Spreads Point Image

    NASA Technical Reports Server (NTRS)

    Edwards, Oliver J.; Arild, Tor

    1992-01-01

    Array of small prisms retrofit to imaging lens. Phase-scrambler plate essentially planar array of small prisms partitioning aperture of lens into many subapertures, and prism at each subaperture designed to divert relatively large diffraction spot formed by that subaperture to different, specific point on focal plane.

  14. Neutron radiography using neutron imaging plate.

    PubMed

    Chankow, Nares; Punnachaiya, Suvit; Wonglee, Sarinrat

    2010-01-01

    The aims of this research are to study properties of a neutron imaging plate (NIP) and to test it for use in nondestructive testing (NDT) of materials. The experiments were carried out by using a BAS-ND 2040 Fuji NIP and a neutron beam from the Thai Research Reactor TRR-1/M1. The neutron intensity and Cd ratio at the specimen position were approximately 9x10(5) ns/cm(2) s and 100 respectively. It was found that the photostimulated luminescence (PSL) readout of the imaging plate was directly proportional to the exposure time and approximately 40 times faster than the conventional NR using Gd converter screen/X-ray film technique. The sensitivities of the imaging plate to slow neutron and to Ir-192 gamma-rays were found to be approximately 4.2x10(-3) PSL/mm(2) per neutron and 6.7x10(-5) PSL/mm(2) per gamma-ray photon respectively. Finally, some specimens containing light elements were selected to be radiographed with neutrons using the NIP and the Gd converter screen/X-ray film technique. The image quality obtained from the two recording media was found to be comparable. Crown Copyright 2009. Published by Elsevier Ltd. All rights reserved.

  15. Guided wave topological imaging of isotropic plates.

    PubMed

    Rodriguez, S; Deschamps, M; Castaings, M; Ducasse, E

    2014-09-01

    Topological imaging is a recent method. So far, it has been applied to bulk waves, and high resolution has been demonstrated for imaging scatterers even with a single ultrasonic insonification of the inspected medium. This method consists of (i) emitting waves and measuring the response of the medium; (ii) solving two propagation problems: the direct problem, where the experimental source is simulated, and the adjoint problem, where the source is the time-reversed difference between the measured wave field and that obtained from the direct problem; (iii) computing the image by simply multiplying both wave fields together in the frequency domain, and integrating over the frequency. The speed of the method depends only on the cost of the field computations that are performed in the defect-free medium. The present work deals with the application of topological imaging to plate guided waves. Combining modal theory and Fourier analysis, the computations are performed in a very short time. In the investigated cases, two-dimensional in-plane imaging is based on propagation of the single S0 Lamb mode. Despite very high dispersion of that mode, scatterers are accurately located and the spatial resolution is equal to about one wavelength.

  16. Modeling and Imaging Flexural Plate Wave Devices

    SciTech Connect

    Adkins, D.R.; Butler, M.A.; Chu, A.S.; Schubert, W.K.

    1999-07-09

    Sandia National Laboratories is developing a new form of flexural plate wave device (FPW) for sensor applications. In this device, Lorentz forces cause out of plane vibrations in a silicon nitride membrane. Current induced in transducer lines on the membrane provides information about the amplitude and phase of these surface vibrations. By tracking the large amplitude vibrations that occur at resonant frequencies, it is possible to infer information about loading on the membrane. In fabricating FPWs, it is important to understand the impact that minor defects can have on operation. Through modeling and testing, they are developing resilient designs that provide large amplitude signals with a high tolerance to defects. A finite element model has been developed to perform design trade-off studies, and results from the model are being verified with a unique measurement system that can image Angstrom scale displacements at vibrational frequencies up to 800 kHz. Results from FPW modeling and imaging efforts are presented in this paper.

  17. Nanosecond gating properties of proximity focused microchannel plate image intensifiers

    NASA Astrophysics Data System (ADS)

    King, N. S. P.; King, N. S. P.; Yates, G. J.; Jaramillo, S. A.; Noel, B. W.; Detch, J. L., Jr.; Ogle, J. W.

    The optical gating properties of Multichannel plate image intensifiers were characterized. Emphasis was placed on parameters relevant to gating speed and correlations between the applied electrical and resultant optical gates.

  18. Novel materials and concepts for neutron image plates

    NASA Astrophysics Data System (ADS)

    Fröhlich-Schlapp, M.; Ioffe, A.; Conrad, H.; Brückel, T.; Fueß, H.; von Seggern, H.

    2005-10-01

    Neutron image plates (NIPs) are used for two-dimensional, position-sensitive detection of neutrons. Commercially available neutron image plates consist of a mixture Gd 2O 3 and BaFBr:Eu 2+. In this contribution we present a system of converter ( 6LiF) and storage phosphor (KCl:Eu 2+), which exhibits a high efficiency for the detection of neutrons, while at the same time features a low γ-sensitivity due to the low atomic numbers. Two different morphologies of image plates based on KCl:Eu 2+- 6LiF were fabricated: ceramic (C-NIPs) and pixelated NIP (Pix-NIPs) . For these NIPs a neutron equivalent of 1/20 neutron per photon for soft γ-rays was found while the equivalent for hard γ-quanta is 1/400 neutron per absorbed photon. The detective quantum efficiency (DQE) of a C-NIP consisting of KCl:Eu 2+- 6LiF amounts to 38%, a value which is comparable to commercially available neutron image plates. Pix-NIPs represent a novel structure in which the scattered light is confined to square cells embedded in the image plate. Due to this light confinement, the resolution of such an image plate is primarily independent of scattering properties of the NIP and is mainly a function of the size of the cell structure used.

  19. Si microchannel plates for image intensification

    NASA Astrophysics Data System (ADS)

    Smith, Arlynn W.; Beetz, Charles P., Jr.; Boerstler, Robert W.; Winn, D. R.; Steinbeck, John W.

    2000-11-01

    Glass microchannel plates (MCPs) have been in use by numerous manufactuers in a variety of electron multiplication applications. Conventional fabrication of MCPs follow the lines of glass drawing and etching technology. Core and clad glass are drawn together, stacked, drawn again, and finally stacked in the desired pattern. The soluble core is removed with wet chemical processing. These techniques are beginning to run into their feasible limits in terms of channel size, open area ratio, uniformity, and material issues. A strong desire exists to fabricate MCPs with accepted lithographic techniques using Si as the base material to improve uniformity and throughput. Open area ratios of as high as 95% have been achieved using lithography. However, attempts to meet other channel plate characteristics met with little success due to thermal runaway or arcing during operation, high voltage is required for electron gain. Processing improvements have lead to the complete oxidation of the Si matrix eliminating the conducting Si in the channel walls of the Si MCPs allowing high voltages to be supported. Complete oxidation of the Si to silica allows processing temperatures high than conventional glass matrices can withstand. This fact allows for high temperature growth of conductive and secondary emissive materials on the channel walls of the structure. Si MCPs with gain have now been fabricated and tested with voltages comparable to conventional glass MCPs. Channel plate characteristics such as operating voltage, strip current, and gain for Si MCPs will be presented and compared to glass MCPs.

  20. Simulation of computed radiography with imaging plate detectors

    SciTech Connect

    Tisseur, D.; Costin, M.; Mathy, F.; Schumm, A.

    2014-02-18

    Computed radiography (CR) using phosphor imaging plate detectors is taking an increasing place in Radiography Testing. CR uses similar equipment as conventional radiography except that the classical X-ray film is replaced by a numerical detector, called image plate (IP), which is made of a photostimulable layer and which is read by a scanning device through photostimulated luminescence. Such digital radiography has already demonstrated important benefits in terms of exposure time, decrease of source energies and thus reduction of radioprotection area besides being a solution without effluents. This paper presents a model for the simulation of radiography with image plate detectors in CIVA together with examples of validation of the model. The study consists in a cross comparison between experimental and simulation results obtained on a step wedge with a classical X-ray tube. Results are proposed in particular with wire Image quality Indicator (IQI) and duplex IQI.

  1. Imaging by Zernike phase plates in the TEM.

    PubMed

    Edgcombe, C J

    2016-08-01

    The images produced from simple phase objects, lenses and Zernike phase plates when all have rotational symmetry can be calculated by 1D Fourier-Bessel transforms. For a simple disc object producing a uniform phase shift over its diameter, the resulting image can be defined for any size of object phase change. The monotonic range of intensity variation with object phase is found to depend strongly on the phase change introduced by the phase plate; this property of the system is not well predicted by the weak phase approximation. The effect of spreading the phase transition at the plate over a range of radius is beneficial if the plate phase change is sufficiently small. Weak-phase calculations for a phase distribution more typical of a spherical object are also shown.

  2. Application of imaging plate to x-ray imaging and spectroscopy in laser plasma experiments

    SciTech Connect

    Izumi, N; Snavely, R; Gregori, G; Koch, J A; Park, H; Remington, B A

    2006-04-25

    We report recent progress of x-ray diagnostic techniques in laser plasma experiment with using imaging plates. Imaging plate is a photo-stimulable phosphor screen (BaF(Br0.85,10.15):Eu{sup 2+}) deposited on flexible metal or plastic substrate. We applied the imaging plate to x-ray microscopy in laser fusion experiment experiments. Self-emission x-ray images of imploded core were obtained successfully with using imaging plate and high magnification target mounted pinhole arrays. The imaging plates were applied also in ultra-intense laser experiment at the Rutherford Appleton Laboratory. Small samarium foil was irradiated by high intensity laser pulse from the Vulcan laser system. The k shell x-rays from the foil ({approx}40keV) was used as a line x-ray source for microscopic radiography. Performance of imaging plate on high-energy x-ray backlit radiography was demonstrated by imaging sinusoidal grooves of 6um amplitude on a Au foil. Detailed spectrum of k shell x-ray from Cu embedded foil target was successfully observed by fully coupling imaging plate with a highly ordered pyrolytic graphite crystal spectrometer. The performances of the imaging plates evaluated in actual laser plasma experiments will be presented.

  3. Tracing the Farallon plate through seismic imaging with USArray

    NASA Astrophysics Data System (ADS)

    Porritt, Robert William

    The Farallon plate system has been subducting off the western United States since at least the middle Mesozoic. This plate has undergone virtually every subduction process during this time including a long episode of flat-slab subduction, generation of microplates, and formation of oceanic plateaus. The shallow remains of this plate are two small microplates, the Gorda and Juan de Fuca, in the Pacific Northwest. The anomalous nature of these two small plates and the missing deeper evidence of subduction has motivated this study. The USArray seismic experiment has provided unprecedented spatial sampling of the seismic wavefield in the continuous United States. Utilizing this dataset, new imaging methods have been implemented and older imaging methods have been revitalized. This study first uses ambient seismic noise in the Pacific Northwest to extract short period Rayleigh waves which are sensitive to lithospheric scale structure. Phase velocities from this model are then combined with teleseismic delay times of body waves and surface waves to image the structure of the continuous United States from the surface through the mantle transition zone. The resolving power of this model allows tracing of the Farallon plate from the trench to the lower mantle. The seismic velocity structure of the continuous United States is broadly composed of a slow western half and fast eastern half separated by the Rocky Mountain Front. The low velocity of the western U.S. contains several high velocity anomalies. While previous work has focused on individual anomalies and suggested they represent lithospheric instabilities, a larger regional view indicates that these are the western remnants of the Farallon plate. Below the thick cratonic lithosphere of the eastern U.S., the Farallon plate contains significant topography due to a subducted heterogeneity of the oceanic plate and a viscosity contrast through the mantle transition zone. The velocity models presented herein provide a

  4. From seismic images to plate dynamics: Towards the full inverse

    NASA Astrophysics Data System (ADS)

    Gurnis, M.; Ratnaswamy, V.; Stadler, G.; Ghattas, O.; Alisic, L.

    2014-12-01

    Three-dimensional seismic images of slabs and other mantle structures provide a first order constraint on the forces driving plate motions. Previous attempts to invert for plate motions from seismic images have blurry slabs that do not act as stress guides. Using forward models, we describe characteristics needed to capture the coupling between mantle structures and plates. In forward models, we capitalized on advances in adaptive mesh refinement and scalable solvers to simulate global mantle flow and plate motions, with plate margins resolved down to 1 km. Cold thermal anomalies within the lower mantle are coupled into oceanic plates through narrow high-viscosity slabs, altering the velocity of oceanic plates. Back-arc extension and slab rollback are emergent consequences of slab descent in the upper mantle. The forward models require the solution of a highly ill-conditioned non-linear Stokes equation. Based on a realistic rheological model with yielding and strain rate weakening from dislocation creep, we formulate inverse problems casted as PDE-constrained optimization problems and derive adjoints of the nonlinear Stokes and incompressibility equations. An inexact-Gauss Newton method is used to infer the rheological parameters while quantifying the uncertainty using the Hessian at the maximum a posteriori (MAP) point. Through 2-D numerical experiments we demonstrate that when the temperature field is known from seismic images, we can recover all of these properties to varying levels of certainty: strength of plate boundaries, yield stress and strain rate exponent in the upper mantle. When the system becomes more unconstrained (when all three mechanical properties are unknown), there can be tradeoffs depending on how well the data approximates the realistic dynamics. As plate boundaries become weaker beyond a limiting value, the uncertainty of the inferred parameters increases due to insensitivity of plate motion to plate coupling. Using the inverse of the

  5. Hyperspectral Imaging for Detecting Pathogens Grown on Agar Plates

    USDA-ARS?s Scientific Manuscript database

    This paper is concerned with the development of a hyperspectral imaging technique for detecting and identifying one of the most common foodborne pathogens, Campylobacter. Direct plating using agars is an effective tool for laboratory tests and analyses of microorganisms. The morphology (size, growth...

  6. Fresnel zone plate light field spectral imaging simulation

    NASA Astrophysics Data System (ADS)

    Hallada, Francis D.; Franz, Anthony L.; Hawks, Michael R.

    2017-05-01

    Through numerical simulation, we have demonstrated a novel snapshot spectral imaging concept using binary diffractive optics. Binary diffractive optics, such as Fresnel zone plates (FZP) or photon sieves, can be used as the single optical element in a spectral imager that conducts both imaging and dispersion. In previous demonstrations of spectral imaging with diffractive optics, the detector array was physically translated along the optic axis to measure different image formation planes. In this new concept the wavelength-dependent images are constructed synthetically, by using integral photography concepts commonly applied to light field (plenoptic) cameras. Light field cameras use computational digital refocusing methods after exposure to make images at different object distances. Our concept refocuses to make images at different wavelengths instead of different object distances. The simulations in this study demonstrate this concept for an imager designed with a FZP. Monochromatic light from planar sources is propagated through the system to a measurement plane using wave optics in the Fresnel approximation. Simple images, placed at optical infinity, are illuminated by monochromatic sources and then digitally refocused to show different spectral bins. We show the formation of distinct images from different objects, illuminated by monochromatic sources in the VIS/NIR spectrum. Additionally, this concept could easily be applied to imaging in the MWIR and LWIR ranges. In conclusion, this new type of imager offers a rugged and simple optical design for snapshot spectral imaging and warrants further development.

  7. Hyperspectral imaging for detecting pathogens grown on agar plates

    NASA Astrophysics Data System (ADS)

    Yoon, Seung Chul; Lawrence, Kurt C.; Siragusa, Gregory R.; Line, John E.; Park, Bosoon; Windham, William R.

    2007-09-01

    This paper is concerned with the development of a hyperspectral imaging technique for detecting and identifying one of the most common foodborne pathogens, Campylobacter. Direct plating using agars is an effective tool for laboratory tests and analyses of microorganisms. The morphology (size, growth pattern, color, etc.) of colonies grown on agar plates has been widely used to tentatively differentiate organisms. However, it is sometimes difficult to differentiate target organisms like Campylobacters from other contaminants grown together on the same agar plates. A hyperspectral imaging system operating at the visible and near infrared (VNIR) spectral region from 400 nm to 900 nm was set up to measure spectral signatures of 17 different Campylobacter and non-Campylobacter subspecies. Protocols for culturing, imaging samples and for calibrating measured data were developed. The VNIR spectral library of all 17 organisms commonly encountered in poultry was established from calibrated hyperspectral images. A classification algorithm was developed to locate and identify Campylobacters, non-Campylobacter contaminants, and background agars with 99.29% accuracy. This research has a potential to be expanded to detect other pathogens grown on agar media.

  8. The character and application of a neutron imaging plate (NIP)

    NASA Astrophysics Data System (ADS)

    Karasawa, Y.; Kumazawa, S.; Miimura, N.

    We have developed a neutron imaging plate (NIP) as a new neutron detector and already reported the fundamental features of the NIP. The optimization of the NIP was carried out by changing a molar ratio of converter materials to PSL (Photostimulated luminescence) materials and thickness of the NIP. Some problems such as γ-ray sensitivity and irradiation effect for the practical use of the NIP were discussed. Several examples of application of the NIP were introduced.

  9. Registration of multiple image sets with thin-plate spline

    NASA Astrophysics Data System (ADS)

    He, Liang; Houk, James C.

    1994-09-01

    A thin-plate spline method for spatial warping was used to register multiple image sets during 3D reconstruction of histological sections. In a neuroanatomical study, the same labeling method was applied to several turtle brains. Each case produced a set of microscopic sections. Spatial warping was employed to map data sets from multiple cases onto a template coordinate system. This technique enabled us to produce an anatomical reconstruction of a neural network that controls limb movement.

  10. Persistence of phosphor glow in microchannel plate image intensifiers

    NASA Technical Reports Server (NTRS)

    Torr, M. R.

    1985-01-01

    Image intensifier tubes using microchannel plate amplification stages and phosphor output stages are being increasingly used in various detection applications. In this paper, measurements of the decay times of what are attributed to be the P20 phosphors in various image intensifiers are reported. It is found that the long tail on the decay curve of the phosphor following illumination can be a limitation for certain observations. In addition, the background level of phosphor glow (which is seen by the subsequent detection system as a light signal) continues to build with continuing illumination.

  11. Hex-square moire patterns in imagers using microchannel plates

    NASA Technical Reports Server (NTRS)

    Lawrence, George M.

    1989-01-01

    In electronic imaging detectors using microchannel plates, the mismatch between the pixels on a square mesh and the microchannels on a hexagonal mesh produces moire image defects. Theoretical statistical estimates of the sizes of the microposition offsets and the flat field intensity errors are calculated, showing the trade-off between resolution and position accuracy. A distinction is made between moments of spot images and moments of the single-pixel-response functions. As the resolution between the hex and square meshes is improved, the detector resolution is improved, but at the expense of an about 10 percent moire pattern. These moire patterns will not be properly corrected by dividing by the flat field image.

  12. Guided wave phased array beamforming and imaging in composite plates.

    PubMed

    Yu, Lingyu; Tian, Zhenhua

    2016-05-01

    This paper describes phased array beamforming using guided waves in anisotropic composite plates. A generic phased array algorithm is presented, in which direction dependent guided wave parameters and the energy skew effect are considered. This beamforming at an angular direction is achieved based on the classic delay-and-sum principle by applying phase delays to signals received at array elements and adding up the delayed signals. The phase delays are determined with the goal to maximize the array output at the desired direction and minimize it otherwise. For array characterization, the beam pattern of rectangular grid arrays in composite plates is derived. In addition to the beam pattern, the beamforming factor in terms of wavenumber distribution is defined to provide intrinsic explanations for phased array beamforming. The beamforming and damage detection in a composite plate are demonstrated using rectangular grid arrays made by a non-contact scanning laser Doppler vibrometer. Detection images of the composite plate with multiple surface defects at various directions are obtained. The results show that the guided wave phased array method is a potential effective method for rapid inspection of large composite structures.

  13. Imaging the Subduction Plate Interface Using Low-Frequency Earthquakes

    NASA Astrophysics Data System (ADS)

    Plourde, A. P.; Bostock, M. G.

    2015-12-01

    Low-frequency Earthquakes (LFEs) in subduction zones are commonly thought to represent slip on the plate interface. They have also been observed to lie near or within a zone of low shear-wave velocity, which is modelled as fluid-rich upper oceanic crust. Due to relatively large depth uncertainties in absolute hypocenters of most LFE families, their location relative to an independently imaged subucting plate and, consequently, the nature of the plate boundary at depths between 30-45 km have not been precisely determined. For a selection of LFE families in northern Washington, we measure variations in arrival time of individual LFE detections using multi-channel cross-correlation incorporating both arrivals at the same station and different events (cross-detection data), and the same event but different stations (cross-station data). Employing HypoDD, these times are used to generate relative locations for individual LFE detections. After creating templates from spatial subgroups of detections, network cross-correlation techniques will be used to search for new detections in neighbouring areas, thereby expanding the local catalogue and enabling further subdivision. By combining the source ``arrays'' and the receiver arrays from the Array of Arrays experiment we plan to interrogate plate boundary structure using migration of scattered waves from the subduction complex as previously documented beneath southern Vancouver Island.

  14. High Speed Large Format Photon Counting Microchannel Plate Imaging Sensors

    NASA Astrophysics Data System (ADS)

    Siegmund, O.; Ertley, C.; Vallerga, J.; Craven, C.; Popecki, M.; O'Mahony, A.; Minot, M.

    The development of a new class of microchannel plate technology, using atomic layer deposition (ALD) techniques applied to a borosilicate microcapillary array is enabling the implementation of larger, more stable detectors for Astronomy and remote sensing. Sealed tubes with MCPs with SuperGenII, bialkali, GaAs and GaN photocathodes have been developed to cover a wide range of optical/UV sensing applications. Formats of 18mm and 25mm circular, and 50mm (Planacon) and 20cm square have been constructed for uses from night time remote reconnaissance and biological single-molecule fluorescence lifetime imaging microscopy, to large area focal plane imagers for Astronomy, neutron detection and ring imaging Cherenkov detection. The large focal plane areas were previously unattainable, but the new developments in construction of ALD microchannel plates allow implementation of formats of 20cm or more. Continuing developments in ALD microchannel plates offer improved overall sealed tube lifetime and gain stability, and furthermore show reduced levels of radiation induced background. High time resolution astronomical and remote sensing applications can be addressed with microchannel plate based imaging, photon time tagging detector sealed tube schemes. Photon counting imaging readouts for these devices vary from cross strip (XS), cross delay line (XDL), to stripline anodes, and pad arrays depending on the intended application. The XS and XDL readouts have been implemented in formats from 22mm, and 50mm to 20cm. Both use MCP charge signals detected on two orthogonal layers of conductive fingers to encode event X-Y positions. XDL readout uses signal propagation delay to encode positions while XS readout uses charge cloud centroiding. Spatial resolution readout of XS detectors can be better than 20 microns FWHM, with good image linearity while using low gain (<10^6), allowing high local counting rates and longer overall tube lifetime. XS tubes with electronics can encode event

  15. Segmenting Microscopy Images of Multi-Well Plates Based on Image Contrast.

    PubMed

    Chen, Weiyang; Liao, Bo; Li, Weiwei; Dong, Xiangjun; Flavel, Matthew; Jois, Markandeya; Li, Guojun; Xian, Bo

    2017-10-01

    Image segmentation is a key process in analyzing biological images. However, it is difficult to detect the differences between foreground and background when the image is unevenly illuminated. The unambiguous segmenting of multi-well plate microscopy images with various uneven illuminations is a challenging problem. Currently, no publicly available method adequately solves these various problems in bright-field multi-well plate images. Here, we propose a new method based on contrast values which removes the need for illumination correction. The presented method is effective enough to distinguish foreground and therefore a model organism (Caenorhabditis elegans) from an unevenly illuminated microscope image. In addition, the method also can solve a variety of problems caused by different uneven illumination scenarios. By applying this methodology across a wide range of multi-well plate microscopy images, we show that our approach can consistently analyze images with uneven illuminations with unparalleled accuracy and successfully solve various problems associated with uneven illumination. It can be used to process the microscopy images captured from multi-well plates and detect experimental subjects from an unevenly illuminated background.

  16. Image segmentation of a color-blindness plate.

    PubMed

    Chen, Y S; Hsu, Y C

    1994-10-10

    One way of testing color vision is with a color-blindness plate (CBP) consisting of a set of brilliant colored dots to form a pattern (a figure) and a set of other colored dots to form a background. Classification of such a type of color image into a pattern and a background with a traditional technique is difficult. Based on a self-organizing feature map and a labeling process as well as spatial distance computation, an effective approach to the segmentation of a CBP image is presented. We describe the principle of a CBP segmentation and then introduce the CBP. The proposed approach is described, and its experimental results are presented. We conclude that the method can segment the CBP image into a pattern and a background successfully.

  17. Imaging characteristics of the Extreme Ultraviolet Explorer microchannel plate detectors

    NASA Technical Reports Server (NTRS)

    Vallerga, J. V.; Kaplan, G. C.; Siegmund, O. H. W.; Lampton, M.; Malina, R. F.

    1989-01-01

    The Extreme Ultraviolet Explorer (EUVE) satellite will conduct an all-sky survey over the wavelength range from 70 A to 760 A using four grazing-incidence telescopes and seven microchannel-plate (MCP) detectors. The imaging photon-counting MCP detectors have active areas of 19.6 cm2. Photon arrival position is determined using a wedge-and-strip anode and associated pulse-encoding electronics. The imaging characteristics of the EUVE flight detectors are presented including image distortion, flat-field response, and spatial differential nonlinearity. Also included is a detailed discussion of image distortions due to the detector mechanical assembly, the wedge-and-strip anode, and the electronics. Model predictions of these distortions are compared to preflight calibration images which show distortions less than 1.3 percent rms of the detector diameter of 50 mm before correction. The plans for correcting these residual detector image distortions to less than 0.1 percent rms are also presented.

  18. Imaging characteristics of the Extreme Ultraviolet Explorer microchannel plate detectors

    NASA Technical Reports Server (NTRS)

    Vallerga, J. V.; Kaplan, G. C.; Siegmund, O. H. W.; Lampton, M.; Malina, R. F.

    1989-01-01

    The Extreme Ultraviolet Explorer (EUVE) satellite will conduct an all-sky survey over the wavelength range from 70 A to 760 A using four grazing-incidence telescopes and seven microchannel-plate (MCP) detectors. The imaging photon-counting MCP detectors have active areas of 19.6 cm2. Photon arrival position is determined using a wedge-and-strip anode and associated pulse-encoding electronics. The imaging characteristics of the EUVE flight detectors are presented including image distortion, flat-field response, and spatial differential nonlinearity. Also included is a detailed discussion of image distortions due to the detector mechanical assembly, the wedge-and-strip anode, and the electronics. Model predictions of these distortions are compared to preflight calibration images which show distortions less than 1.3 percent rms of the detector diameter of 50 mm before correction. The plans for correcting these residual detector image distortions to less than 0.1 percent rms are also presented.

  19. Radiation stability of CsBr:Eu needle image plates

    NASA Astrophysics Data System (ADS)

    Batentschuk, M.; Neudert, S.; Weidner, M.; Osvet, A.; Struye, L.; Tahon, J.-P.; Leblans, P.

    2009-10-01

    Needle image plates (NIPs) based on CsBr:Eu are a good alternative to the BaFBr:Eu powder image plates due to their higher sensitivity and improved spatial resolution. The x-ray radiation stability of the NIPs produced by Agfa Gevaert was investigated and it was found that the radiation stability of the optimized NIPs is as high as that of the commercial CsI:Tl single crystals and much higher than reported in literature for the CsBr:Eu NIPs. The dependence of the sensitivity of the NIPs on the accumulated dose was determined for three different types of x-ray irradiation. It is shown that degradation of the sensitivity starts at about 10 Gy and it is the strongest for the most hard x-ray beam. If the energy absorbed by a NIP is taken into account, the degradation does not depend on the hardness of the applied x-ray beam. It is suggested that the main reason for the observed high radiation stability of the CsBr:Eu NIPs is the use of the oxygen-free Eu2+-containing precursor CsEuBr3 for the doping in the manufacturing process.

  20. Radiation stability of CsBr:Eu needle image plates

    SciTech Connect

    Batentschuk, M.; Neudert, S.; Weidner, M.; Osvet, A.; Struye, L.; Tahon, J.-P.; Leblans, P.

    2009-10-15

    Needle image plates (NIPs) based on CsBr:Eu are a good alternative to the BaFBr:Eu powder image plates due to their higher sensitivity and improved spatial resolution. The x-ray radiation stability of the NIPs produced by Agfa Gevaert was investigated and it was found that the radiation stability of the optimized NIPs is as high as that of the commercial CsI:Tl single crystals and much higher than reported in literature for the CsBr:Eu NIPs. The dependence of the sensitivity of the NIPs on the accumulated dose was determined for three different types of x-ray irradiation. It is shown that degradation of the sensitivity starts at about 10 Gy and it is the strongest for the most hard x-ray beam. If the energy absorbed by a NIP is taken into account, the degradation does not depend on the hardness of the applied x-ray beam. It is suggested that the main reason for the observed high radiation stability of the CsBr:Eu NIPs is the use of the oxygen-free Eu{sup 2+}-containing precursor CsEuBr{sub 3} for the doping in the manufacturing process.

  1. Method of obtaining intensified image from developed photographic films and plates

    NASA Technical Reports Server (NTRS)

    Askins, B. S. (Inventor)

    1978-01-01

    A method is explained of obtaining intensified images from silver images on developed photographic films and plates. The steps involve converting silver of the developed film or plate to a radioactive compound by treatment with an aqueous alkaline solution of an organo-S35 compound; placing the treated film or plate in direct contact with a receiver film which is then exposed by radiation from the activated film; and developing and fixing the resulting intensified image on the receiver film.

  2. A neutron diffractometer for biological macromolecules using neutron imaging plates

    NASA Astrophysics Data System (ADS)

    Fujiwara, S.; Karasawa, Y.; Tanaka, I.; Minezaki, Y.; Yonezawa, Y.; Niimura, N.

    Neutron imaging plates (NIPs), developed recently, have a good spatial resolution and availability of a large sensitive area. The NIPs having such characteristics may be particularly useful for neutron-diffraction measurements of biological macromolecules. We have constructed a neutron diffractometer dedicated to crystallography of biological macromolecules using the NIP, in the guide hall of the reactor JRR-3M at Japan Atomic Energy Research Institute. Neutrons are monochromatized with an elastically-bent-silicon monochromator ( λ = 0.22 nm). The diffraction patterns are detected with the NIP of 400 × 520 mm 2 at a distance of 150-300 mm from a sample crystal. A sequence of the measurements (exposure, reading the NIP, erasure of the pattern, and starting the next exposure) is done automatically. We measured the diffraction patterns from hen egg-white lysozyme crystals, and obtained the patterns which can be processed to derive integrated intensity of each diffraction spot.

  3. Collimator application for microchannel plate image intensifier resolution improvement

    DOEpatents

    Thomas, Stanley W.

    1996-02-27

    A collimator is included in a microchannel plate image intensifier (MCPI). Collimators can be useful in improving resolution of MCPIs by eliminating the scattered electron problem and by limiting the transverse energy of electrons reaching the screen. Due to its optical absorption, a collimator will also increase the extinction ratio of an intensifier by approximately an order of magnitude. Additionally, the smooth surface of the collimator will permit a higher focusing field to be employed in the MCP-to-collimator region than is currently permitted in the MCP-to-screen region by the relatively rough and fragile aluminum layer covering the screen. Coating the MCP and collimator surfaces with aluminum oxide appears to permit additional significant increases in the field strength, resulting in better resolution.

  4. Collimator application for microchannel plate image intensifier resolution improvement

    DOEpatents

    Thomas, S.W.

    1996-02-27

    A collimator is included in a microchannel plate image intensifier (MCPI). Collimators can be useful in improving resolution of MCPIs by eliminating the scattered electron problem and by limiting the transverse energy of electrons reaching the screen. Due to its optical absorption, a collimator will also increase the extinction ratio of an intensifier by approximately an order of magnitude. Additionally, the smooth surface of the collimator will permit a higher focusing field to be employed in the MCP-to-collimator region than is currently permitted in the MCP-to-screen region by the relatively rough and fragile aluminum layer covering the screen. Coating the MCP and collimator surfaces with aluminum oxide appears to permit additional significant increases in the field strength, resulting in better resolution. 2 figs.

  5. Neutron detection with imaging plates Part I. Image storage and readout

    NASA Astrophysics Data System (ADS)

    Thoms, M.; Myles, D.; Wilkinson, C.

    1999-11-01

    The detection of neutrons with imaging plates is based on a sequence of physical processes, which are happening during the neutron exposure and the readout of the image information. These processes are investigated in detail starting with the neutron absorption and conversion to secondary radiation by various neutron converter materials and ending with the detection of the photostimulated luminescence, which is emitted during the readout. It is shown that these processes can be quantified by several key parameters, such as i.e. the neutron absorption cross section, the emitted secondary energy and the conversion efficiency of released secondary energy to storage centers in the storage phosphor. The resulting detector characteristics are described in the second part, namely, Neutron detection with imaging plates - part II: detector characteristics [Nucl. Instr. and Meth. A 424 (1999) 34-39].

  6. Direct Imaging Searches with the Apodizing Phase Plate Coronagraph

    NASA Astrophysics Data System (ADS)

    Kenworthy, M.; Meshkat, T.; Otten, , G.; Codona, J.

    2014-03-01

    The sensitivity of direct imaging searches for extrasolar planets is limited by the presence of diffraction rings from the primary star. Coronagraphs are angular filters that minimise these diffraction structures whilst allowing light from faint companions to shine through. The Apodizing Phase Plate (APP; Kenworthy 2007) coronagraph is a simple pupil plane optic that suppresses diffraction over a 180 degree region around each star simultaneously, providing easy beam switching observations and requiring no time consuming optical alignment at the telescope. We will present our results on using the APP at the Very Large Telescope in surveys for extrasolar planets around A/F and debris disk hosting stars in the L' band (3.8 microns) in the Southern Hemisphere, where we reach a contrast of 12 magnitudes at 0.5 arcseconds (Meshkat 2013). In Leiden, we are also developing the next generation of broadband achromatic coronagraphs that can simultaneously image both sides of the star using Vector APPs (Snik 2012, Otten 2012). Recent laboratory results showing the potential of this technology for future ELTs will also be presented.

  7. Recognition of blurred license plate of vehicle based on natural image matting

    NASA Astrophysics Data System (ADS)

    Liang, Fangfang; Liu, Yong; Yao, Gang

    2009-10-01

    Car's license plate identification system based on image processing is one of the key technologies of intelligent transportation system. In most cases, license plate numbers can be accurately recognized by the generic identification systems while the image is clear. However, sometime the license plate are seriously blurred by some dunghill such as mud or water smoke before camera lens, which is hard to be identified. In order to get higher recognition rate of blurred license plate, an approach based on natural image matting is proposed in this paper.

  8. Retrofit implementation of Zernike phase plate imaging for cryo-TEM

    PubMed Central

    Marko, Michael; Leith, ArDean; Hsieh, Chyongere; Danev, Radostin

    2011-01-01

    In-focus phase-plate imaging is particularly beneficial for cryo-TEM because it offers a substantial overall increase in image contrast, without an electron dose penalty, and it simplifies image interpretation. We show how phase-plate cryo-TEM can be implemented with an appropriate existing TEM, and provide a basic practical introduction to use of thin-film (carbon) phase plates. We point out potential pitfalls of phase-plate operation, and discuss solutions. We provide information on evaluating a particular TEM for its suitability. PMID:21272647

  9. A modified commercial scanner as an image plate for table-top optical applications

    SciTech Connect

    Casado-Rojo, S; Lorenzana, H E; Baonza, V G

    2008-12-09

    A reliable, accurate, and inexpensive optical detector for table-top applications is described here. Based on a commercial high resolution office scanner coupled to a projection on plate, it enables a large image plate surface, allowing recording of large images without systematic errors associated to coupling optics' aberrations. Several tests on distance-dependent and steady interference patterns will be presented and discussed. The extension to other types of optical measurement by substituting the projection on plate is proposed.

  10. Robust technique using an imaging plate to detect environmental radioactivity.

    PubMed

    Isobe, Tomonori; Mori, Yutaro; Takada, Kenta; Sato, Eisuke; Sakurai, Hideyuki; Sakae, Takeji

    2013-04-01

    The Fukushima Daiichi Nuclear Power Plant was severely damaged by the Great East Japan Earthquake on 11 March 2011. Consequently, a large amount of radioactive material was accidentally released. Recently, the focus has been on quantification of environmental radioactive material. However, conventional techniques require complicated and expensive measurement equipment. In this research, the authors developed a simple method to detect environmental radioactive material with an imaging plate (IP). Two specific measurement subjects were targeted: measurements for the depth distribution of radioactive material in soil and surface contamination of a building roof. For the measurement of depth distribution of radioactive material in soil, the authors ascertained that the concentration of environmental radioactivity was highest at 5 cm below the surface, and it decreased with depth. For the measurement of surface contamination of the building roof, the authors created a contamination map of the building roof. The detector developed could contact the ground directly, and unlike other survey meters, it was not influenced by peripheral radioactivity. In this study, the authors verified the feasibility of measurement of environmental radioactivity with an IP. Although the measured values of the IP were relative, further work is planned to perform evaluations of absolute quantities of radioactive material.

  11. Musculoskeletal ultrasound for preoperative imaging of the plantar plate: a prospective analysis.

    PubMed

    Klein, Erin E; Weil, Lowell; Weil, Lowell Scott; Knight, Jessica

    2013-06-01

    The purpose of this study was to prospectively compare preoperative findings on musculoskeletal ultrasound evaluation to observed intraoperative findings for patients undergoing surgical correction of plantar plate tears. Fifty consecutive patients with forefoot pain and a suspected unilateral plantar plate tear at the second metatarsophalangeal (MTP) joint were identified. The same examiner performed a 2-plane (longitudinal and transverse) musculoskeletal ultrasound on the painful second MTP joint. The contralateral second MTP joint was used for comparison. Longitudinal ultrasound images were graded as "torn" or "intact." Transverse ultrasound images were used to localize the suspected pathology. Results of the ultrasound were compared with observed intraoperative pathology. Forty-five plantar plate tears were identified intraoperatively. Longitudinal ultrasound images correctly identified 40 plantar plate tears. The longitudinal ultrasound had a sensitivity of 91.1%, a specificity of 25%, a positive predictive value of 91.1%, and a negative predictive value of 25%. Transverse ultrasound images identified 36 plantar plate tears correctly localizing only 19 tears. Musculoskeletal ultrasound has been widely used to identify and localize pathology in many soft tissue structures. Whereas the longitudinal ultrasound images were useful in identifying plantar plate tears, the same cannot be said about the ability to localize the tear on the transverse ultrasound images. Therefore, ultrasound may not be as good an imaging modality as magnetic resonance imaging for identification and localization of plantar plate pathology.

  12. A new fast and large area neutron detector using a novel image plate readout technique.

    PubMed

    Schillinger, B; Baumann, J; Gebele, H; Schaetzing, R; Schaller, H; Schuster, M

    2004-10-01

    At Agfa Medical Imaging Systems, a new type of image plate scanner is being developed. Instead of scanning the irradiated image plate with a single laser and reading the luminescence information with a single light collector and photomultiplier, the new system employs a whole line of laser diodes and a set of CCD line sensors. This technique allows for virtually unlimited detection areas and a very fast readout.

  13. Calibration of the linear response range of x-ray imaging plates and their reader based on image grayscale values.

    PubMed

    Ren, Kuan; Xu, Tao; Zheng, Jianhua; Dong, Jianjun; Wei, Minxi; Li, Chaoguang; Cao, Zhurong; Du, Huabing; Yan, Ji; Yang, Guohong; Yi, Rongqing; Zhang, Jiyan; Huang, Tianxuan; Liu, Shenye; Wang, Feng; Yang, Zhiwen; Li, Jin; Chen, Yaohua; Lan, Ke; Ren, Guoli; Liu, Jie; Ding, Yongkun; Jiang, Shaoen

    2017-08-01

    X-ray imaging plates are one of the most important X-ray imaging detectors and are widely used in inertial-confinement fusion experiments. However, their linear response range, which is the foundation of their quantitative data analysis, has not been sufficiently deeply investigated. In this work, we develop an X-ray fluorescer calibration system and carefully explore the linear response range of X-ray imaging plates. For the first time, nearly the entire grayscale range of the X-ray imaging plate linear response-7819-64 879 in the range of 0-65 535-has been observed. Further, we discuss the uncertainties involved in the calibration process. This work demonstrates the excellent linear response qualities of X-ray imaging plates and provides a significant foundation for expanding their quantitative applied range.

  14. Calibration of the linear response range of x-ray imaging plates and their reader based on image grayscale values

    NASA Astrophysics Data System (ADS)

    Ren, Kuan; Xu, Tao; Zheng, Jianhua; Dong, Jianjun; Wei, Minxi; Li, Chaoguang; Cao, Zhurong; Du, Huabing; Yan, Ji; Yang, Guohong; Yi, Rongqing; Zhang, Jiyan; Huang, Tianxuan; Liu, Shenye; Wang, Feng; Yang, Zhiwen; Li, Jin; Chen, Yaohua; Lan, Ke; Ren, Guoli; Liu, Jie; Ding, Yongkun; Jiang, Shaoen

    2017-08-01

    X-ray imaging plates are one of the most important X-ray imaging detectors and are widely used in inertial-confinement fusion experiments. However, their linear response range, which is the foundation of their quantitative data analysis, has not been sufficiently deeply investigated. In this work, we develop an X-ray fluorescer calibration system and carefully explore the linear response range of X-ray imaging plates. For the first time, nearly the entire grayscale range of the X-ray imaging plate linear response—7819-64 879 in the range of 0-65 535—has been observed. Further, we discuss the uncertainties involved in the calibration process. This work demonstrates the excellent linear response qualities of X-ray imaging plates and provides a significant foundation for expanding their quantitative applied range.

  15. Cross-calibration of Fuji TR image plate and RAR 2492 x-ray film to determine the response of a DITABIS Super Micron image plate scanner.

    PubMed

    Dunham, G; Harding, E C; Loisel, G P; Lake, P W; Nielsen-Weber, L B

    2016-11-01

    Fuji TR image plate is frequently used as a replacement detector medium for x-ray imaging and spectroscopy diagnostics at NIF, Omega, and Z facilities. However, the familiar Fuji BAS line of image plate scanners is no longer supported by the industry, and so a replacement scanning system is needed. While the General Electric Typhoon line of scanners could replace the Fuji systems, the shift away from photo stimulated luminescence units to 16-bit grayscale Tag Image File Format (TIFF) leaves a discontinuity when comparing data collected from both systems. For the purposes of quantitative spectroscopy, a known unit of intensity applied to the grayscale values of the TIFF is needed. The DITABIS Super Micron image plate scanning system was tested and shown to potentially rival the resolution and dynamic range of Kodak RAR 2492 x-ray film. However, the absolute sensitivity of the scanner is unknown. In this work, a methodology to cross calibrate Fuji TR image plate and the absolutely calibrated Kodak RAR 2492 x-ray film is presented. Details of the experimental configurations used are included. An energy dependent scale factor to convert Fuji TR IP scanned on a DITABIS Super Micron scanner from 16-bit grayscale TIFF to intensity units (i.e., photons per square micron) is discussed.

  16. Cross-calibration of Fuji TR image plate and RAR 2492 x-ray film to determine the response of a DITABIS Super Micron image plate scanner

    NASA Astrophysics Data System (ADS)

    Dunham, G.; Harding, E. C.; Loisel, G. P.; Lake, P. W.; Nielsen-Weber, L. B.

    2016-11-01

    Fuji TR image plate is frequently used as a replacement detector medium for x-ray imaging and spectroscopy diagnostics at NIF, Omega, and Z facilities. However, the familiar Fuji BAS line of image plate scanners is no longer supported by the industry, and so a replacement scanning system is needed. While the General Electric Typhoon line of scanners could replace the Fuji systems, the shift away from photo stimulated luminescence units to 16-bit grayscale Tag Image File Format (TIFF) leaves a discontinuity when comparing data collected from both systems. For the purposes of quantitative spectroscopy, a known unit of intensity applied to the grayscale values of the TIFF is needed. The DITABIS Super Micron image plate scanning system was tested and shown to potentially rival the resolution and dynamic range of Kodak RAR 2492 x-ray film. However, the absolute sensitivity of the scanner is unknown. In this work, a methodology to cross calibrate Fuji TR image plate and the absolutely calibrated Kodak RAR 2492 x-ray film is presented. Details of the experimental configurations used are included. An energy dependent scale factor to convert Fuji TR IP scanned on a DITABIS Super Micron scanner from 16-bit grayscale TIFF to intensity units (i.e., photons per square micron) is discussed.

  17. Cross-calibration of Fuji TR image plate and RAR 2492 x-ray film to determine the response of a DITABIS Super Micron image plate scanner

    SciTech Connect

    Dunham, G. Harding, E. C.; Loisel, G. P.; Lake, P. W.; Nielsen-Weber, L. B.

    2016-11-15

    Fuji TR image plate is frequently used as a replacement detector medium for x-ray imaging and spectroscopy diagnostics at NIF, Omega, and Z facilities. However, the familiar Fuji BAS line of image plate scanners is no longer supported by the industry, and so a replacement scanning system is needed. While the General Electric Typhoon line of scanners could replace the Fuji systems, the shift away from photo stimulated luminescence units to 16-bit grayscale Tag Image File Format (TIFF) leaves a discontinuity when comparing data collected from both systems. For the purposes of quantitative spectroscopy, a known unit of intensity applied to the grayscale values of the TIFF is needed. The DITABIS Super Micron image plate scanning system was tested and shown to potentially rival the resolution and dynamic range of Kodak RAR 2492 x-ray film. However, the absolute sensitivity of the scanner is unknown. In this work, a methodology to cross calibrate Fuji TR image plate and the absolutely calibrated Kodak RAR 2492 x-ray film is presented. Details of the experimental configurations used are included. An energy dependent scale factor to convert Fuji TR IP scanned on a DITABIS Super Micron scanner from 16-bit grayscale TIFF to intensity units (i.e., photons per square micron) is discussed.

  18. Single Transducer Ultrasonic Imaging Method that Eliminates the Effect of Plate Thickness Variation in the Image

    NASA Technical Reports Server (NTRS)

    Roth, Don J.

    1996-01-01

    This article describes a single transducer ultrasonic imaging method that eliminates the effect of plate thickness variation in the image. The method thus isolates ultrasonic variations due to material microstructure. The use of this method can result in significant cost savings because the ultrasonic image can be interpreted correctly without the need for machining to achieve precise thickness uniformity during nondestructive evaluations of material development. The method is based on measurement of ultrasonic velocity. Images obtained using the thickness-independent methodology are compared with conventional velocity and c-scan echo peak amplitude images for monolithic ceramic (silicon nitride), metal matrix composite and polymer matrix composite materials. It was found that the thickness-independent ultrasonic images reveal and quantify correctly areas of global microstructural (pore and fiber volume fraction) variation due to the elimination of thickness effects. The thickness-independent ultrasonic imaging method described in this article is currently being commercialized under a cooperative agreement between NASA Lewis Research Center and Sonix, Inc.

  19. High-speed imaging of Raleigh-Taylor instabilities in laser-driven plates

    NASA Astrophysics Data System (ADS)

    Frank, Alan M.; Gillespie, Calvin H.; Trott, Wayne M.

    1997-05-01

    We have previously reported our observations of the dynamic behavior of laser driven plates. Recent improvements and modification of the imaging techniques have identified and provided measurements of Raleigh-Taylor (R-T) instabilities that occur in these events. The microscope system in the LLNL Micro Detonics Facility, was converted to an epi- illuminated polarization configuration. A double pulse nanosecond illuminator and a second independently focusable frame camera were also added to the system. A laser driven plate, that is a dense solid driven by a laser heated, lower density plasma, is inherently R-T unstable. The characteristics and growth of the instability determine whether or not the plate remains intact. In earlier reports we correlated the surface patterning of thin plates with the fiber-optical transmission modes. In subsequent experiments we noted that the plasma burn through patterning in thin plates and the surface patterning of thicker plates did not correspond to the thin plate early time patterning. These observations led to the suspicion of R-T instability. A series of experiments correlating plate thickness and pattern spatial frequency has verified the instability. The plates are aluminum, deposited on the ends of optical fibers. They are launched by a YAG laser pulse traveling down the fiber. Plate velocities are several kilometers per second and characteristic dimensions of the instabilities are a few to tens of microns. Several techniques were used to examine the plates, the most successful being specularly reflecting polarization microscopy looking directly at the plate as it flies toward the camera. These images gave data on the spatial frequencies of the instabilities but could not give the amplitudes. To measure the amplitude of the instability a semi-transparent witness plate was placed a known distance from the plate. As above, the plate was observed using the polarization microscope but using the streak camera as the detector

  20. Effects of low-spatial-frequency response of phase plates on TEM imaging

    NASA Astrophysics Data System (ADS)

    Edgcombe, C. J.

    2015-10-01

    Images of simple objects produced by a perfect lens and a phase plate have been calculated by use of Abbe theory for Foucault, Hilbert and Zernike phase plates. The results show that with a Zernike plate, white outlines and ringing like those observed previously can be caused by the beam hole, which limits the low-spatial-frequency response of the system even when the lens behaves perfectly. When the change of phase added by the phase plate is distributed over a range of radius rather than a simple step, the unwanted effects are substantially reduced.

  1. A seismic reflection image for the base of a tectonic plate.

    PubMed

    Stern, T A; Henrys, S A; Okaya, D; Louie, J N; Savage, M K; Lamb, S; Sato, H; Sutherland, R; Iwasaki, T

    2015-02-05

    Plate tectonics successfully describes the surface of Earth as a mosaic of moving lithospheric plates. But it is not clear what happens at the base of the plates, the lithosphere-asthenosphere boundary (LAB). The LAB has been well imaged with converted teleseismic waves, whose 10-40-kilometre wavelength controls the structural resolution. Here we use explosion-generated seismic waves (of about 0.5-kilometre wavelength) to form a high-resolution image for the base of an oceanic plate that is subducting beneath North Island, New Zealand. Our 80-kilometre-wide image is based on P-wave reflections and shows an approximately 15° dipping, abrupt, seismic wave-speed transition (less than 1 kilometre thick) at a depth of about 100 kilometres. The boundary is parallel to the top of the plate and seismic attributes indicate a P-wave speed decrease of at least 8 ± 3 per cent across it. A parallel reflection event approximately 10 kilometres deeper shows that the decrease in P-wave speed is confined to a channel at the base of the plate, which we interpret as a sheared zone of ponded partial melts or volatiles. This is independent, high-resolution evidence for a low-viscosity channel at the LAB that decouples plates from mantle flow beneath, and allows plate tectonics to work.

  2. A seismic reflection image for the base of a tectonic plate

    NASA Astrophysics Data System (ADS)

    Stern, T. A.; Henrys, S. A.; Okaya, D.; Louie, J. N.; Savage, M. K.; Lamb, S.; Sato, H.; Sutherland, R.; Iwasaki, T.

    2015-02-01

    Plate tectonics successfully describes the surface of Earth as a mosaic of moving lithospheric plates. But it is not clear what happens at the base of the plates, the lithosphere-asthenosphere boundary (LAB). The LAB has been well imaged with converted teleseismic waves, whose 10-40-kilometre wavelength controls the structural resolution. Here we use explosion-generated seismic waves (of about 0.5-kilometre wavelength) to form a high-resolution image for the base of an oceanic plate that is subducting beneath North Island, New Zealand. Our 80-kilometre-wide image is based on P-wave reflections and shows an approximately 15° dipping, abrupt, seismic wave-speed transition (less than 1 kilometre thick) at a depth of about 100 kilometres. The boundary is parallel to the top of the plate and seismic attributes indicate a P-wave speed decrease of at least 8 +/- 3 per cent across it. A parallel reflection event approximately 10 kilometres deeper shows that the decrease in P-wave speed is confined to a channel at the base of the plate, which we interpret as a sheared zone of ponded partial melts or volatiles. This is independent, high-resolution evidence for a low-viscosity channel at the LAB that decouples plates from mantle flow beneath, and allows plate tectonics to work.

  3. Measurement of steel plate perforation tests with digital image correlation.

    SciTech Connect

    Cordova, Theresa Elena; Reu, Phillip L.; Vangoethem, Douglas J.

    2009-03-01

    The results of a series of punch-through tests performed on steel plates are presented. The geometry consisted of circular plates with welded boundary condition penetrated by a conical shaped punch with either a radiused or flat cylindrical end. After initial failure, the conical portion of the punch was driven through the plate to exercise tearing mechanics. Tests were performed quasi-statically with a hydraulic actuator and dynamically using a high-capacity drop table. Deformation and strain were measured with a stereo DIC system. The quasi-static tests utilized a conventional direct-view DIC technique while the dynamic tests required development of an indirect-view technique using a mirror. Experimental details used to conduct the test series will be presented along with test results. Methods of assessing test-to-test repeatability will be discussed. DIC results will also be synchronized and compared with transducer data (displacement and strain).

  4. Hyperspectral image reconstruction using RGB color for foodborne pathogen detection on agar plates

    NASA Astrophysics Data System (ADS)

    Yoon, Seung-Chul; Shin, Tae-Sung; Park, Bosoon; Lawrence, Kurt C.; Heitschmidt, Gerald W.

    2014-03-01

    This paper reports the latest development of a color vision technique for detecting colonies of foodborne pathogens grown on agar plates with a hyperspectral image classification model that was developed using full hyperspectral data. The hyperspectral classification model depended on reflectance spectra measured in the visible and near-infrared spectral range from 400 and 1,000 nm (473 narrow spectral bands). Multivariate regression methods were used to estimate and predict hyperspectral data from RGB color values. The six representative non-O157 Shiga-toxin producing Eschetichia coli (STEC) serogroups (O26, O45, O103, O111, O121, and O145) were grown on Rainbow agar plates. A line-scan pushbroom hyperspectral image sensor was used to scan 36 agar plates grown with pure STEC colonies at each plate. The 36 hyperspectral images of the agar plates were divided in half to create training and test sets. The mean Rsquared value for hyperspectral image estimation was about 0.98 in the spectral range between 400 and 700 nm for linear, quadratic and cubic polynomial regression models and the detection accuracy of the hyperspectral image classification model with the principal component analysis and k-nearest neighbors for the test set was up to 92% (99% with the original hyperspectral images). Thus, the results of the study suggested that color-based detection may be viable as a multispectral imaging solution without much loss of prediction accuracy compared to hyperspectral imaging.

  5. Complete erasing of ghost images caused by deeply trapped electrons on computed radiography plates

    NASA Astrophysics Data System (ADS)

    Ohuchi, H.; Kondo, Y.

    2011-03-01

    The ghost images, i.e., latent image that is unerasable with visible light (LIunVL) and reappearing image appeared on computed radiography (CR) plates were completely erased by simultaneous exposing them to filtered ultraviolet light and visible light. Three different types of CR plates (Agfa, Kodak, and Fuji) were irradiated with 50 kV X-ray beams in the dose range 8.1 mGy to 8.0 Gy, and then conventionally erased for 2 h with visible light. The remaining LIunVL could be erased by repeating 6 h simultaneous exposures to filtered ultraviolet light and visible light. After the sixth round of exposure, all the LIunVL in the three types of CR plates were erased to the same level as in an unirradiated plate and no latent images reappeared after storage at 0°C for 14 days. The absorption spectra of deep centers were specified using polychromatic ultraviolet light from a deep-ultraviolet lamp. It was found that deep centers showed a dominant peak in the absorption spectra at around 324 nm for the Agfa and Kodak plates, and at around 320 nm for the Fuji plate, in each case followed by a few small peaks. After completely erasing CR plates, these peaks were no longer observed.

  6. A fast microchannel plate-scintillator detector for velocity map imaging and imaging mass spectrometry

    SciTech Connect

    Winter, B.; King, S. J.; Vallance, C.; Brouard, M.

    2014-02-15

    The time resolution achievable using standard position-sensitive ion detectors, consisting of a chevron pair of microchannel plates coupled to a phosphor screen, is primarily limited by the emission lifetime of the phosphor, around 70 ns for the most commonly used P47 phosphor. We demonstrate that poly-para-phenylene laser dyes may be employed extremely effectively as scintillators, exhibiting higher brightness and much shorter decay lifetimes than P47. We provide an extensive characterisation of the properties of such scintillators, with a particular emphasis on applications in velocity-map imaging and microscope-mode imaging mass spectrometry. The most promising of the new scintillators exhibits an electron-to-photon conversion efficiency double that of P47, with an emission lifetime an order of magnitude shorter. The new scintillator screens are vacuum stable and show no signs of signal degradation even over longer periods of operation.

  7. A fast microchannel plate-scintillator detector for velocity map imaging and imaging mass spectrometry.

    PubMed

    Winter, B; King, S J; Brouard, M; Vallance, C

    2014-02-01

    The time resolution achievable using standard position-sensitive ion detectors, consisting of a chevron pair of microchannel plates coupled to a phosphor screen, is primarily limited by the emission lifetime of the phosphor, around 70 ns for the most commonly used P47 phosphor. We demonstrate that poly-para-phenylene laser dyes may be employed extremely effectively as scintillators, exhibiting higher brightness and much shorter decay lifetimes than P47. We provide an extensive characterisation of the properties of such scintillators, with a particular emphasis on applications in velocity-map imaging and microscope-mode imaging mass spectrometry. The most promising of the new scintillators exhibits an electron-to-photon conversion efficiency double that of P47, with an emission lifetime an order of magnitude shorter. The new scintillator screens are vacuum stable and show no signs of signal degradation even over longer periods of operation.

  8. (99m)Tc thyroid imaging system using multiple imaging plates.

    PubMed

    Ito, Shigeki; Saze, Takuya; Ariga, Eiji; Deji, Shizuhiko; Hirota, Masahiro; Nishizawa, Kunihide

    2009-06-01

    A system for taking static thyroid (99m)Tc images was devised by using multiple imaging plates (IPs) and a low-energy high resolution collimator. System spatial resolution of the IP systems and the gamma camera was determined by referring to standards set by the National Electrical Manufacturers Association. Sensitivity was represented by using lower detection limits (LDLs). The sensitivity and resolution of IP systems using 16 IP probes connecting two collimators and 9 IPs were determined by using a 20 ml thyroid phantom, and compared with the sensitivity of gamma cameras. The sensitivity of the IP systems increased in proportion to the number of IPs. The sensitivity and resolution of a probe using 6 IPs and a high resolution collimator were equivalent to or superior to the gamma camera for taking static thyroid (99m)Tc images. IP systems can be applied clinically as mobile static nuclear imaging devices. The performance of IP systems should be thoroughly investigated for combinations of various collimators and the number of IPs in order to verify their efficacy for imaging all organs.

  9. Optimisation of lithium borate barium chloride glass-ceramic thermal neutron imaging plates

    NASA Astrophysics Data System (ADS)

    Appleby, G. A.; Vontobel, P.

    2008-09-01

    Glass-ceramic thermal neutron imaging plates (NIPs) recently reported have been further developed for use in neutron radiography. The plate consists of nanocrystallites of the storage phosphor BaCl 2:Eu 2+ embedded within a neutron-sensitive lithium borate glass-matrix. A new generation of samples, enriched with both 10B and 6Li with thicknesses in the range 280-500 μm have been studied. Neutron images were read out using a Fuji BAS2500 imaging plate scanner and the quality of the images obtained was comparable to those recorded on a commercial NIP. Details of the response to neutron-irradiation as well as the obtained spatial resolution of the images are presented. The neutron absorption and radiation hardness of the materials studied is also measured.

  10. Multicenter Evaluation of an Image Analysis Device (APAS): Comparison Between Digital Image and Traditional Plate Reading Using Urine Cultures.

    PubMed

    Glasson, John; Hill, Rhys; Summerford, Michael; Olden, Dianne; Papadopoulos, Fotula; Young, Stephen; Giglio, Steven

    2017-11-01

    The application of image analysis technologies for the interpretation of microbiological cultures is evolving rapidly. The primary aim of this study was to establish whether the image analysis system named Automated Plate Assessment System (APAS; LBT Innovations Ltd., Australia) could be applied to screen urine cultures. A secondary aim was to evaluate differences between traditional plate reading (TPR) and the reading of cultures from images, or digital plate reading (DPR). A total of 9,224 urine samples submitted for culture to three clinical laboratories, two in Australia and one in the USA, were included in the study. Cultures were prepared on sheep blood and MacConkey agar plates and read by panels of three microbiologists. The plates were then presented to APAS for image capture and analysis, and the images and results were stored for later review. Image analysis of cultures using APAS produced a diagnostic sensitivity and specificity of 99.0% and 84.5%, respectively. Colonies were detected by APAS on 99.0% of blood agar plates with growth and on 99.5% of MacConkey agar plates. DPR agreed with TPR for colony enumeration on 92.1% of the plates, with a sensitivity of 90.8% and specificity of 92.8% for case designation. However, several differences in the classification of colony morphologies using DPR were identified. APAS was shown to be a reliable screening system for urine cultures. The study also showed acceptable concordance between DPR and TPR for colony detection, enumeration, and case designation.

  11. Characterization of pulsed (plasma focus) neutron source with image plate and application to neutron radiography

    SciTech Connect

    Andola, Sanjay; Niranjan, Ram; Rout, R. K.; Kaushik, T. C.; Gupta, S. C.; Shaikh, A. M.

    2013-02-05

    Plasma focus device of Mather type developed in house has been used first time for neutron radiography of different objects. The device gives (1.2{+-}0.3) Multiplication-Sign 10{sup 9} neutrons per pulse produced by D-D fusion reaction with a pulse width of 50{+-}5 ns. The method involves exposing sample to be radiographed to thermalized D-D neutrons and recording the image on Fuji-film BAS-ND image plates. The thermal neutron component of the moderated beam was estimated using two image plates: a conventional IP for X-rays and gamma rays, and an IP doped with Gd for detecting neutrons.

  12. Fresnel zone plates for Achromatic Imaging Survey of X-ray sources

    SciTech Connect

    Palit, Sourav; Chakrabarti, S. K.; Debnath, D.; Yadav, Vipin; Nandi, Anuj

    2008-10-08

    A telescope with Fresnel Zone Plates has been contemplated to be an excellent imaging mask in X-rays and gamma-rays for quite some time. With a proper choice of zone plate material, spacing and an appropriate readout system it is possible to achieve any theoretical angular resolution. We provide the results of numerical simulations of how a large number of X-ray sources could be imaged at a high resolution. We believe that such an imager would be an excellent tool for a future survey mission for X-ray and gamma-ray sources which we propose.

  13. Electrothermal MEMS parallel plate rotation for single-imager stereoscopic endoscopes.

    PubMed

    Jang, Kyung-Won; Yang, Sung-Pyo; Baek, Seung-Hwan; Lee, Min-Suk; Park, Hyeon-Cheol; Seo, Yeong-Hyeon; Kim, Min H; Jeong, Ki-Hun

    2016-05-02

    This work reports electrothermal MEMS parallel plate-rotation (PPR) for a single-imager based stereoscopic endoscope. A thin optical plate was directly connected to an electrothermal MEMS microactuator with bimorph structures of thin silicon and aluminum layers. The fabricated MEMS PPR device precisely rotates an transparent optical plate up to 37° prior to an endoscopic camera and creates the binocular disparities, comparable to those from binocular cameras with a baseline distance over 100 μm. The anaglyph 3D images and disparity maps were successfully achieved by extracting the local binocular disparities from two optical images captured at the relative positions. The physical volume of MEMS PPR is well fit in 3.4 mm x 3.3 mm x 1 mm. This method provides a new direction for compact stereoscopic 3D endoscopic imaging systems.

  14. Application of atomic layer deposited microchannel plates to imaging photodetectors with high time resolution

    SciTech Connect

    Siegmund, O; McPhate, J; Tremsin, Anton S; Vallerga, J V; Ertley, C D; Richner, N J; Gerard, T M; Frisch, H.; Elam, Jeffrey W.; Mane, Anil U.; Wagner, Robert G.; Minot, Michael J.; O'Mahony, Aileen O; Craven, C A

    2015-07-01

    Novel microchannel plates have been constructed using borosilicate glass micro-capillary array substrates with 20 mu m and 10 mu m pores and coated with resistive, and secondary electron emissive, layers by atomic layer deposition. Microchannel plates in 33 mm, 50 mm and 20 cm square formats have been made and tested. Although their amplification, imaging, and timing properties are comparable to standard glass microchannel plates, the background rates and lifetime characteristics are considerably improved. Sealed tube detectors based on the Planacon tube, and a 25 mm cross delay line readout tube with a GaN(Mg) opaque photocathode deposited on borosilicate microchannel plates have been fabricated. Considerable progress has also been made with 20 cm microchannel plates for a 20 cm format sealed tube sensor with strip-line readout that is being developed for Cherenkov light detection.

  15. Automated Cell Detection and Morphometry on Growth Plate Images of Mouse Bone

    PubMed Central

    Ascenzi, Maria-Grazia; Du, Xia; Harding, James I; Beylerian, Emily N; de Silva, Brian M; Gross, Ben J; Kastein, Hannah K; Wang, Weiguang; Lyons, Karen M; Schaeffer, Hayden

    2014-01-01

    Microscopy imaging of mouse growth plates is extensively used in biology to understand the effect of specific molecules on various stages of normal bone development and on bone disease. Until now, such image analysis has been conducted by manual detection. In fact, when existing automated detection techniques were applied, morphological variations across the growth plate and heterogeneity of image background color, including the faint presence of cells (chondrocytes) located deeper in tissue away from the image’s plane of focus, and lack of cell-specific features, interfered with identification of cell. We propose the first method of automated detection and morphometry applicable to images of cells in the growth plate of long bone. Through ad hoc sequential application of the Retinex method, anisotropic diffusion and thresholding, our new cell detection algorithm (CDA) addresses these challenges on bright-field microscopy images of mouse growth plates. Five parameters, chosen by the user in respect of image characteristics, regulate our CDA. Our results demonstrate effectiveness of the proposed numerical method relative to manual methods. Our CDA confirms previously established results regarding chondrocytes’ number, area, orientation, height and shape of normal growth plates. Our CDA also confirms differences previously found between the genetic mutated mouse Smad1/5CKO and its control mouse on fluorescence images. The CDA aims to aid biomedical research by increasing efficiency and consistency of data collection regarding arrangement and characteristics of chondrocytes. Our results suggest that automated extraction of data from microscopy imaging of growth plates can assist in unlocking information on normal and pathological development, key to the underlying biological mechanisms of bone growth. PMID:25525552

  16. Nondestructive imaging of hidden figures on license plates by X-ray radiograph.

    PubMed

    Jeon, Oc-Yeub; Kim, Sang-Hyeon; Lee, Joong; Park, Jong-Taek; Kim, Tae-Hoon; Park, Hak-Soo; Huh, Il-Kwon; Kang, Hyung-Tae

    2009-07-01

    In this case, we investigated the modified license plates. The evidences had new embossing pressed serial numbers after erasing the original numbers on the license plates by hammering. The X-ray radiograph could visualize the hidden figures; those were virtually unseen by naked eyes or undetectable by ordinary photography. To reveal the erased figures, we performed image processing with computer software after X-ray radiographs. It proved to be an efficient nondestructive way to visualize the hidden original figures on metals.

  17. Dead-time effects in microchannel-plate imaging detectors

    NASA Technical Reports Server (NTRS)

    Zombeck, Martin V.; Fraser, George W.

    1991-01-01

    The observed counting rates of microchannel plate (MCP) based detectors for high resolution observations of celestial EUV and X-ray sources vary over many orders of magnitude; the counting capability of an individual channel, however, is not high, and is associated with dead-times ranging from 0.1 msec to 1 sec. The dead-time increases with the area illuminated; attention is presently given to laboratory determinations of the count rate characteristics of a MCP detector as a function of illuminated area, and a model is developed for these results' use in the interpretation of space observations.

  18. X-ray imaging using the thermoluminescent properties of commercial Al2O3 ceramic plates.

    PubMed

    Shinsho, Kiyomitsu; Kawaji, Yasuyuki; Yanagisawa, Shin; Otsubo, Keisuke; Koba, Yusuke; Wakabayashi, Genichiro; Matsumoto, Kazuki; Ushiba, Hiroaki

    2016-05-01

    This research demonstrated that commercially available alumina is well-suited for use in large area X-ray detectors. We discovered a new radiation imaging device that has a high spatial resolution, high sensitivity, wide dynamic range, large imaging area, repeatable results, and low operating costs. The high thermoluminescent (TL) properties of Al2O3 ceramic plates make them useful for X-ray imaging devices.

  19. A guided ultrasonic imaging approach in isotropic plate structures using edge reflections

    NASA Astrophysics Data System (ADS)

    Ebrahimkhanlou, Arvin; Dubuc, Brennan; Salamone, Salvatore

    2016-04-01

    This paper presents an imaging technique to locate damage in plate-like structures by permanently attached piezoelectric transducers (PZT) capable to generate and receive guided ultrasonic waves. The technique is based on a model capable of predicting envelope of scattered waves. Correlations between the estimated scattered waves and experimental data are used for image reconstruction. The approach is validated on an aluminum plate and results are compared with two common imaging algorithms, that is, Delay and Sum (DS) and Minimum Variance (MV). Damage is simulated by placing two magnets on sides of the plate. It is shown that the inclusion of Lamb wave reflections improves the localization accuracy while making use of fewer number of sensors possible.

  20. High-energy x-ray backlighter spectrum measurements using calibrated image plates

    SciTech Connect

    Maddox, B.R.; Park, H.S.; Remington, B.A.; Izumi, N.; Chen, S.; Chen, C.; Kimminau, G.; Ali, Z.; Haugh, M.J.; Ma, Q.

    2012-10-10

    The x-ray spectrum between 18 and 88 keV generated by a petawatt laser driven x-ray backlighter target was measured using a 12-channel differential filter pair spectrometer. The spectrometer consists of a series of filter pairs on a Ta mask coupled with an x-ray sensitive image plate. A calibration of Fuji{trademark} MS and SR image plates was conducted using a tungsten anode x-ray source and the resulting calibration applied to the design of the Ross pair spectrometer. Additionally, the fade rate and resolution of the image plate system were measured for quantitative radiographic applications. The conversion efficiency of laser energy into silver K{alpha} x rays from a petawatt laser target was measured using the differential filter pair spectrometer and compared to measurements using a single photon counting charge coupled device.

  1. Tonpilz piezoelectric transducers with acoustic matching plates for underwater color image transmission.

    PubMed

    Inoue, T; Nada, T; Tsuchiya, T; Nakanishi, T; Miyama, T; Konno, M

    1993-01-01

    Tonpilz piezoelectric transducers with multiple acoustic matching plates are suitable for color image acoustic transmission, to achieve wideband low-ripple characteristics as well as high-efficiency high-power transmitting capability. The design method for the transducers was investigated on the basis of multiple-mode filter synthesis theory. For transducers with single, double, and triple matching plates, optimum specific acoustic impedances and lengths were calculated. Moreover, based on this design method, a 24 kHz array comprising nine identical transducers with single matching plates was built and evaluated. As a result, this array showed high-efficiency, low-ripple, and wideband characteristics. Excellent agreement between theoretical values and experimental results was obtained. A field test was carried out on color image transmission from a 3500 m sea depth, using the fabricated array, during which good color images were received.

  2. Calibration of Fuji BAS-SR type imaging plate as high spatial resolution x-ray radiography recorder

    NASA Astrophysics Data System (ADS)

    Yan, Ji; Zheng, Jianhua; Zhang, Xing; Chen, Li; Wei, Minxi

    2017-05-01

    Image Plates as x-ray recorder have advantages including reusable, high dynamic range, large active area, and so on. In this work, Fuji BAS-SR type image plate combined with BAS-5000 scanner is calibrated. The fade rates of Image Plates has been measured using x-ray diffractometric in different room temperature; the spectral response of Image Plates has been measured using 241Am radioactive sealed source and fitting with linear model; the spatial resolution of Image Plates has been measured using micro-focus x-ray tube. The results show that Image Plates has an exponent decade curve and double absorption edge response curve. The spatial resolution of Image Plates with 25μ/50μ scanner resolution is 6.5lp/mm, 11.9lp/mm respectively and gold grid radiography is collected with 80lp/mm spatial resolution using SR-type Image Plates. BAS-SR type Image Plates can do high spatial resolution and quantitative radiographic works. It can be widely used in High energy density physics (HEDP), inertial confinement fusion (ICF) and laboratory astronomy physics.

  3. Neutron diffractometer for bio-crystallography (BIX) with an imaging plate neutron detector

    SciTech Connect

    Niimura, Nobuo

    1994-12-31

    We have constructed a dedicated diffractometer for neutron crystallography in biology (BIX) on the JRR-3M reactor at JAERI (Japan Atomic Energy Research Institute). The diffraction intensity from a protein crystal is weaker than that from most inorganic materials. In order to overcome the intensity problem, an elastically bent silicon monochromator and a large area detector system were specially designed. A preliminary result of diffraction experiment using BIX has been reported. An imaging plate neutron detector has been developed and a feasibility experiment was carried out on BIX. Results are reported. An imaging plate neutron detector has been developed and a feasibility test was carried out using BIX.

  4. Image plate characterization and absolute calibration to low kilo-electron-volt electrons.

    PubMed

    Busold, S; Philipp, K; Otten, A; Roth, M

    2014-11-01

    We report on the characterization of an image plate and its absolute calibration to electrons in the low keV energy range (1-30 keV). In our case, an Agfa MD4.0 without protection layer was used in combination with a Fuji FLA7000 scanner. The calibration data are compared to other published data and a consistent picture of the sensitivity of image plates to electrons is obtained, which suggests a validity of the obtained calibration up to 100 keV.

  5. Image plate characterization and absolute calibration to low kilo-electron-volt electrons

    NASA Astrophysics Data System (ADS)

    Busold, S.; Philipp, K.; Otten, A.; Roth, M.

    2014-11-01

    We report on the characterization of an image plate and its absolute calibration to electrons in the low keV energy range (1-30 keV). In our case, an Agfa MD4.0 without protection layer was used in combination with a Fuji FLA7000 scanner. The calibration data are compared to other published data and a consistent picture of the sensitivity of image plates to electrons is obtained, which suggests a validity of the obtained calibration up to 100 keV.

  6. Image plate characterization and absolute calibration to low kilo-electron-volt electrons

    SciTech Connect

    Busold, S.; Philipp, K.; Otten, A.; Roth, M.

    2014-11-15

    We report on the characterization of an image plate and its absolute calibration to electrons in the low keV energy range (1–30 keV). In our case, an Agfa MD4.0 without protection layer was used in combination with a Fuji FLA7000 scanner. The calibration data are compared to other published data and a consistent picture of the sensitivity of image plates to electrons is obtained, which suggests a validity of the obtained calibration up to 100 keV.

  7. The effect of copper conversion plates on low-Z target image quality.

    PubMed

    Parsons, David; Robar, James L

    2012-09-01

    Common electronic portal imaging devices (EPIDs) contain a 1.0 mm copper conversion plate to increase detection efficiency of a therapeutic megavoltage spectrum. When used in imaging with a photon beam generated with a low atomic number (Z) target, the conversion plate attenuates a substantial proportion of photons in the diagnostic range, thereby reducing the achievable image quality. In this work, we measure directly dependence on low-Z target image quality as a function of copper plate thickness, for both planar imaging and cone beam computed tomography (CBCT). Monte Carlo modeling was used to quantify changes to the diagnostic spectrum and detector response for low-Z target beams generated with either 2.35 or 7.00 MeV electrons incident on a carbon target. Planar contrast-to-noise ratio (CNR) and spatial resolution measurements were made as a function of copper thickness. CNR measurements were made for CBCT imaging as a function of dose both with and without the copper plate present in the EPID. The presence of copper in the EPID decreased the diagnostic photon population by up to 20% and suppressed the peak detector response (dose deposited in the scintillator) at 60 keV by a factor of 6.4. Planar CNR was increased by a factor ranging from 1.4 to 4.0, depending on the material imaged, with no copper present compared to a standard 1.0 mm thickness. Planar spatial resolution was only slightly degraded with increasing copper thickness. Increases in CBCT image CNR ranged from a factor of 1.3-2.1 with the copper plate removed. It is possible to increase the proportion of photons in the diagnostic energy range (25 keV-150 keV) reaching the phosphor screen by as much as 20% when removing the copper conversion plate. This results in significant increases of planar and CBCT image CNR. Consequently, we suggest that the copper conversion plate be removed from the EPID when used for low-Z target planar or CBCT imaging.

  8. Crack Imaging and Quantification in Aluminum Plates with Guided Wave Wavenumber Analysis Methods

    NASA Technical Reports Server (NTRS)

    Yu, Lingyu; Tian, Zhenhua; Leckey, Cara A. C.

    2015-01-01

    Guided wavefield analysis methods for detection and quantification of crack damage in an aluminum plate are presented in this paper. New wavenumber components created by abrupt wave changes at the structural discontinuity are identified in the frequency-wavenumber spectra. It is shown that the new wavenumbers can be used to detect and characterize the crack dimensions. Two imaging based approaches, filter reconstructed imaging and spatial wavenumber imaging, are used to demonstrate how the cracks can be evaluated with wavenumber analysis. The filter reconstructed imaging is shown to be a rapid method to map the plate and any existing damage, but with less precision in estimating crack dimensions; while the spatial wavenumber imaging provides an intensity image of spatial wavenumber values with enhanced resolution of crack dimensions. These techniques are applied to simulated wavefield data, and the simulation based studies show that spatial wavenumber imaging method is able to distinguish cracks of different severities. Laboratory experimental validation is performed for a single crack case to confirm the methods' capabilities for imaging cracks in plates.

  9. Crack Imaging and Quantification in Aluminum Plates with Guided Wave Wavenumber Analysis Methods

    NASA Technical Reports Server (NTRS)

    Yu, Lingyu; Tian, Zhenhua; Leckey, Cara A. C.

    2015-01-01

    Guided wavefield analysis methods for detection and quantification of crack damage in an aluminum plate are presented in this paper. New wavenumber components created by abrupt wave changes at the structural discontinuity are identified in the frequency-wavenumber spectra. It is shown that the new wavenumbers can be used to detect and characterize the crack dimensions. Two imaging based approaches, filter reconstructed imaging and spatial wavenumber imaging, are used to demonstrate how the cracks can be evaluated with wavenumber analysis. The filter reconstructed imaging is shown to be a rapid method to map the plate and any existing damage, but with less precision in estimating crack dimensions; while the spatial wavenumber imaging provides an intensity image of spatial wavenumber values with enhanced resolution of crack dimensions. These techniques are applied to simulated wavefield data, and the simulation based studies show that spatial wavenumber imaging method is able to distinguish cracks of different severities. Laboratory experimental validation is performed for a single crack case to confirm the methods' capabilities for imaging cracks in plates.

  10. Crack imaging and quantification in aluminum plates with guided wave wavenumber analysis methods.

    PubMed

    Yu, Lingyu; Tian, Zhenhua; Leckey, Cara A C

    2015-09-01

    Guided wavefield analysis methods for detection and quantification of crack damage in an aluminum plate are presented in this paper. New wavenumber components created by abrupt wave changes at the structural discontinuity are identified in the frequency-wavenumber spectra. It is shown that the new wavenumbers can be used to detect and characterize the crack dimensions. Two imaging based approaches, filter reconstructed imaging and spatial wavenumber imaging, are used to demonstrate how the cracks can be evaluated with wavenumber analysis. The filter reconstructed imaging is shown to be a rapid method to map the plate and any existing damage, but with less precision in estimating crack dimensions; while the spatial wavenumber imaging provides an intensity image of spatial wavenumber values with enhanced resolution of crack dimensions. These techniques are applied to simulated wavefield data, and the simulation based studies show that spatial wavenumber imaging method is able to distinguish cracks of different severities. Laboratory experimental validation is performed for a single crack case to confirm the methods' capabilities for imaging cracks in plates.

  11. The capacitive division image readout: a novel imaging device for microchannel plate detectors

    NASA Astrophysics Data System (ADS)

    Lapington, J. S.; Conneely, T. M.; Leach, S. A.; Moore, L.

    2013-09-01

    The Capacitive Division Image Readout (C-DIR) is a simple and novel image readout for photon counting detectors offering major performance advantages. C-DIR is a charge centroiding device comprising three elements; (i) a resistive anode providing event charge localization, event current return path and electrical isolation from detector high voltage, (ii) a dielectric substrate which capacitively couples the event transient signal to the third element, (iii) the readout device; an array of capacitively coupled electrodes which divides the signal among the readout charge measurement nodes. The resistive anode and dielectric substrate constitute the rear interface of the detector and capacitively couple the signal to the external C-DIR readout device. The C-DIR device is a passive, multilayer printed circuit board type device comprising a matrix of isolated electrodes whose geometries define the capacitive network. C-DIR is manufactured using conventional PCB geometries and is straightforward and economical to construct. C-DIR's robustness and simplicity belie its performance advantages. Its capacitive nature avoids partition noise, the Poisson noise associated with collection of discrete charges. The dominant noise limiting position resolution is electronic noise. However C-DIR also presents a low input capacitance to the readout electronics, minimising this noise component thus maximising spatial resolution. Optimisation of the C-DIR pattern-edge geometry can provide ~90% linear dynamic range. We present data showing image resolution and linearity of the C-DIR device in a microchannel plate detector and describe various electronic charge measurement scheme designed to exploit the full performance potential of the C-DIR device.

  12. Complete erasing of ghost images on computed radiography plates and role of deeply trapped electrons

    NASA Astrophysics Data System (ADS)

    Ohuchi-Yoshida, Hiroko; Kondo, Yasuhiro

    2011-12-01

    Computed radiography (CR) plates made of europium-doped Ba(Sr)FBr(I) were simultaneously exposed to filtered ultraviolet light and visible light in order to erase ghost images, i.e., latent image that is unerasable with visible light (LIunVL) and reappearing one, which are particularly observed in plates irradiated with a high dose and/or cumulatively over-irradiated. CR samples showing LIunVLs were prepared by irradiating three different types of CR plates (Agfa ADC MD10, Kodak Directview Mammo EHRM2, and Fuji ST-VI) with 50 kV X-ray beams in the dose range 8.1 mGy-8.0 Gy. After the sixth round of simultaneous 6 h exposures to filtered ultraviolet light and visible light, all the LIunVLs in the three types of CR plates were erased to the same level as in an unirradiated plate and no latent images reappeared after storage at 0 °C for 14 days. With conventional exposure to visible light, LIunVLs consistently remained in all types of CR plates irradiated with higher doses of X-rays and latent images reappeared in the Agfa M10 plates after storage at 0 °C. Electrons trapped in deep centers cause LIunVLs and they can be erased by simultaneous exposures to filtered ultraviolet light and visible light. To study electrons in deep centers, the absorption spectra were examined in all types of irradiated CR plates by using polychromatic ultraviolet light from a deep-ultraviolet lamp. It was found that deep centers showed a dominant peak in the absorption spectra at around 324 nm for the Agfa M10 and Kodak EHRM2 plates, and at around 320 nm for the Fuji ST-VI plate, in each case followed by a few small peaks. The peak heights were dose-dependent for all types of CR samples, suggesting that the number of electrons trapped in deep centers increases with the irradiation dose.

  13. Effect of alternative photostimulable phosphor plates erasing times on subjective digital image quality.

    PubMed

    Melo, D P; Dos Anjos Pontual, A; de Almeida, S M; Campos, P S F; Alves, M C; Tosoni, G M

    2010-01-01

    To evaluate the influence of alternative erasing times of DenOptix(R) (Dentsply/Gendex, Chicargo, IL) digital plates on subjective image quality and the probability of double exposure image not occurring. Human teeth were X-rayed with phosphor plates using ten different erasing times. Two observers evaluated the images for subjective image quality (sharpness, brightness, contrast, enamel definition, dentin definition and dentin-enamel junction definition) and for the presence or absence of double exposure image. Spearman's correlation analysis and ANOVA was performed to verify the existence of a linear association between the subjective image quality parameters and the alternative erasing times. A contingency table was constructed to evaluate the agreement among the observers, and a binominal logistic regression was performed to verify the correlation between the erasing time and the probability of double exposure image not occurring. All 6 parameters of image quality were rated high by the examiners for the erasing times between 25 s and 130 s. The same erasing time range, from 25 to 130 s, was considered a safe erasing time interval, with no probability of a double exposure image occurring. The alternative erasing times from 25 s to 130 s showed high image quality and no probability of double image occurrence. Thus, it is possible to reduce the operating time of the DenOptix(R) digital system without jeopardizing the diagnostic task.

  14. Improved computed radiography image quality from a BaFl:Eu photostimulable phosphor plate.

    PubMed

    Nakano, Yasushi; Gido, Tomonori; Honda, Satoshi; Maezawa, Akihiro; Wakamatsu, Hideaki; Yanagita, Takafumi

    2002-04-01

    Recent advances in the design of photostimulable phosphor (PSP) plates for computed radiography (CR) systems have made it possible to manufacture plates made of BaFI:Eu phosphor material in the cassette form. The image quality of this plate, six BaF(Br,I):Eu plates, and one BaFBr:Eu plate were evaluated in terms of presampling modulation transfer function (MTF), normalized Wiener spectra (WSN), and detective quantum efficiency (DQE). Compared with the best-performing BaF(Br,I):Eu plate, the BaFI:Eu plate provided DQE that was higher, at spatial frequencies of 0.5, 1.0, and 2.0 cycles/mm, by 12% (21.8 versus 19.4), 13% (18.8 versus 16.7), and 11% (12.0 versus 10.8), respectively. Since presampling MTF values of the two plates were comparable, the BaFI:Eu plate's higher DQE is attributable to total WSN conversely being lower by 17% [8.65 x 10(-5) (mm2) versus 10.38 x 10(-5) (mm2)], 17% [5.85 x 10(-5) (mm2) versus 7.03 x 10(-5) (mm2)], and 12% [2.82 x 10(-5) (mm2) versus 3.19 x 10(-5) (mm2)] at the specified frequencies, respectively, primarily due to the contribution of x-ray quantum WSN. This jibes with the high x-ray absorption provided by the 27%-higher x-ray attenuation coefficients (7.54 versus 6.07, at 60 KeV) that BaFI offers over BaF(Br(0.85),I(0.15)), a result of the high atomic number of BaFI's exclusively iodine halide content. The results were consistent with earlier studies of several of these same plates and indicate that BaFI:Eu is a promising avenue to lower image noise and higher overall CR system image quality.

  15. Development of a new type of imaging detector with capillary plate

    SciTech Connect

    Tsukahara, M.; Sakurai, H.; Saito, S.

    1996-12-31

    We have developed a new type of proportional counter utilizing a capillary plate with the capability of fine imaging power. Light outputs of the CGPC (Capillary Gas Proportional Counter) due to gas proportional scintillation are investigated by an optical imaging apparatus featured an intensified CCD camera to the CGPC. We successfully detected a image of {alpha}-particle track with a fill gas of xenon + 5% methane. It indicates first evidence of the gas multiplication in a thin capillary. We describe in detail the light output of the CGPC and characteristics of the imaging due to the CGPC.

  16. A multiple-plate, multiple-pinhole camera for X-ray gamma-ray imaging

    NASA Technical Reports Server (NTRS)

    Hoover, R. B.

    1971-01-01

    Plates with identical patterns of precisely aligned pinholes constitute lens system which, when rotated about optical axis, produces continuous high resolution image of small energy X-ray or gamma ray source. Camera has applications in radiation treatment and nuclear medicine.

  17. Calibration of photon counting imaging microchannel plate detectors for EUV astronomy

    NASA Technical Reports Server (NTRS)

    Siegmund, O. H. W.; Vallerga, J.; Jelinsky, P.

    1986-01-01

    The calibration of photon counting imaging detectors for satellite based EUV astronomy is a complex process designed to ensure the validity of the data received 'in orbit'. The methods developed to accomplish calibration of microchannel plate detectors for the Extreme Ultraviolet Explorer are described and illustrated. The characterization of these detectors can be subdivided into three categories: stabilization, performance tests, and environmental tests.

  18. Calibration of photon counting imaging microchannel plate detectors for EUV astronomy

    NASA Technical Reports Server (NTRS)

    Siegmund, O. H. W.; Vallerga, J.; Jelinsky, P.

    1986-01-01

    The calibration of photon counting imaging detectors for satellite based EUV astronomy is a complex process designed to ensure the validity of the data received 'in orbit'. The methods developed to accomplish calibration of microchannel plate detectors for the Extreme Ultraviolet Explorer are described and illustrated. The characterization of these detectors can be subdivided into three categories: stabilization, performance tests, and environmental tests.

  19. Hyperspectral image reconstruction using RGB color for foodborne pathogen detection on agar plates

    USDA-ARS?s Scientific Manuscript database

    This paper reports the latest development of a color vision technique for detecting colonies of foodborne pathogens grown on agar plates with a hyperspectral image classification model that was developed using full hyperspectral data. The hyperspectral classification model depended on reflectance sp...

  20. Integration of image analysis and robotics into a fully automated colony picking and plate handling system.

    PubMed Central

    Jones, P; Watson, A; Davies, M; Stubbings, S

    1992-01-01

    We describe here the integration of image analysis and robotics to produce a fully automated colony picking/plate handling system. Biological tests were performed to verify its performance in terms of sterilisation and accuracy of picking. The machine was then used by a single operative to pick a 36,000 clone cDNA library in approximately 42 hrs over 5 days. Images PMID:1408762

  1. Application of hydrogen analysis by neutron imaging plate method to Zircaloy cladding tubes

    NASA Astrophysics Data System (ADS)

    Yasuda, Ryou; Nakata, Masahito; Matsubayashi, Masahito; Harada, Katsuya; Hatakeyama, Yuichi; Amano, Hidetoshi

    2003-08-01

    Effectiveness of neutron imaging plate (NIP) method for hydrogen analysis is investigated by using standard samples with known hydrogen concentrations. A relationship between hydrogen concentration in Zircaloy tubes and numerical data in the NIP images was obtained by image analysis process. By using the relationship, local hydrogen concentrations in segregated tubes with heterogeneous hydrogen distribution were estimated in a small area; 0.1 × 0.1 mm 2. Contribution of an oxide film in the tubes to the images is also investigated by using oxidized samples with and without hydrides. In the NIP images of the oxidized samples, oxide film was not recognized in the images of the sample. Results of numerical analysis also show no effect of the oxide film. These results show that the effect of oxygen in the image can be neglected when hydrogen analysis is performed on the Zircaloy tube with oxide film and hydrides by NIP method.

  2. Amphibious seismic survey images plate interface at 1960 Chile Earthquake

    NASA Astrophysics Data System (ADS)

    The SPOC Team; Krawcyzk, C.

    The southern central Chilean margin at the site of the largest historically recorded earthquake in the Valdivia region, in 1960 (Mw = 9.5), is part of the 5000-km-long active subduction system whose geodynamic evolution is controversially debated and poorly understood. Covering the area between 36° and 40°S, the oceanic crust is segmented by prominent fracture zones. The offshore forearc and its onshore continuation show a complex image with segments of varying geophysical character, and several fault systems active during the past 24 m.y.In autumn 2001, the project SPOC was organized to study the Subduction Processes Off Chile, with a focus on the seismogenic coupling zone and the forearc. The acquired seismic data crossing the Chilean subduction system were gathered in a combined offshore-onshore survey and provide new insights into the lithospheric structure and evolution of active margins with insignificant frontal accretion.

  3. Bifractal focusing and imaging properties of Thue-Morse Zone Plates.

    PubMed

    Ferrando, Vicente; Giménez, Fernando; Furlan, Walter D; Monsoriu, Juan A

    2015-07-27

    We present a new family of Zone Plates (ZPs) designed using the Thue-Morse sequence. The focusing and imaging properties of these aperiodic diffractive lenses coined Thue-Morse Zone Plates (TMZPs) are examined. It is demonstrated that TMZPs produce a pair of self-similar and equally intense foci along the optical axis. As a consequence of this property, under broadband illumination, a TMZP produces two foci with an extended depth of focus and a strong reduction of the chromatic aberration compared with conventional periodic ZPs. This distinctive optical characteristic is experimentally confirmed.

  4. Damage imaging in a laminated composite plate using an air-coupled time reversal mirror

    DOE PAGES

    Le Bas, P. -Y.; Remillieux, M. C.; Pieczonka, L.; ...

    2015-11-03

    We demonstrate the possibility of selectively imaging the features of a barely visible impact damage in a laminated composite plate by using an air-coupled time reversal mirror. The mirror consists of a number of piezoelectric transducers affixed to wedges of power law profiles, which act as unconventional matching layers. The transducers are enclosed in a hollow reverberant cavity with an opening to allow progressive emission of the ultrasonic wave field towards the composite plate. The principle of time reversal is used to focus elastic waves at each point of a scanning grid spanning the surface of the plate, thus allowingmore » localized inspection at each of these points. The proposed device and signal processing removes the need to be in direct contact with the plate and reveals the same features as vibrothermography and more features than a C-scan. More importantly, this device can decouple the features of the defect according to their orientation, by selectively focusing vector components of motion into the object, through air. For instance, a delamination can be imaged in one experiment using out-of-plane focusing, whereas a crack can be imaged in a separate experiment using in-plane focusing. As a result, this capability, inherited from the principle of time reversal, cannot be found in conventional air-coupled transducers.« less

  5. Damage imaging in a laminated composite plate using an air-coupled time reversal mirror

    SciTech Connect

    Le Bas, P. -Y.; Remillieux, M. C.; Pieczonka, L.; Ten Cate, J. A.; Anderson, B. E.; Ulrich, T. J.

    2015-11-03

    We demonstrate the possibility of selectively imaging the features of a barely visible impact damage in a laminated composite plate by using an air-coupled time reversal mirror. The mirror consists of a number of piezoelectric transducers affixed to wedges of power law profiles, which act as unconventional matching layers. The transducers are enclosed in a hollow reverberant cavity with an opening to allow progressive emission of the ultrasonic wave field towards the composite plate. The principle of time reversal is used to focus elastic waves at each point of a scanning grid spanning the surface of the plate, thus allowing localized inspection at each of these points. The proposed device and signal processing removes the need to be in direct contact with the plate and reveals the same features as vibrothermography and more features than a C-scan. More importantly, this device can decouple the features of the defect according to their orientation, by selectively focusing vector components of motion into the object, through air. For instance, a delamination can be imaged in one experiment using out-of-plane focusing, whereas a crack can be imaged in a separate experiment using in-plane focusing. As a result, this capability, inherited from the principle of time reversal, cannot be found in conventional air-coupled transducers.

  6. Damage imaging in a laminated composite plate using an air-coupled time reversal mirror

    NASA Astrophysics Data System (ADS)

    Le Bas, P.-Y.; Remillieux, M. C.; Pieczonka, L.; Ten Cate, J. A.; Anderson, B. E.; Ulrich, T. J.

    2015-11-01

    We demonstrate the possibility of selectively imaging the features of a barely visible impact damage in a laminated composite plate by using an air-coupled time reversal mirror. The mirror consists of a number of piezoelectric transducers affixed to wedges of power law profiles, which act as unconventional matching layers. The transducers are enclosed in a hollow reverberant cavity with an opening to allow progressive emission of the ultrasonic wave field towards the composite plate. The principle of time reversal is used to focus elastic waves at each point of a scanning grid spanning the surface of the plate, thus allowing localized inspection at each of these points. The proposed device and signal processing removes the need to be in direct contact with the plate and reveals the same features as vibrothermography and more features than a C-scan. More importantly, this device can decouple the features of the defect according to their orientation, by selectively focusing vector components of motion into the object, through air. For instance, a delamination can be imaged in one experiment using out-of-plane focusing, whereas a crack can be imaged in a separate experiment using in-plane focusing. This capability, inherited from the principle of time reversal, cannot be found in conventional air-coupled transducers.

  7. gitter: a robust and accurate method for quantification of colony sizes from plate images.

    PubMed

    Wagih, Omar; Parts, Leopold

    2014-03-20

    Colony-based screens that quantify the fitness of clonal populations on solid agar plates are perhaps the most important source of genome-scale functional information in microorganisms. The images of ordered arrays of mutants produced by such experiments can be difficult to process because of laboratory-specific plate features, morphed colonies, plate edges, noise, and other artifacts. Most of the tools developed to address this problem are optimized to handle a single setup and do not work out of the box in other settings. We present gitter, an image analysis tool for robust and accurate processing of images from colony-based screens. gitter works by first finding the grid of colonies from a preprocessed image and then locating the bounds of each colony separately. We show that gitter produces comparable colony sizes to other tools in simple cases but outperforms them by being able to handle a wider variety of screens and more accurately quantify colony sizes from difficult images. gitter is freely available as an R package from http://cran.r-project.org/web/packages/gitter under the LGPL. Tutorials and demos can be found at http://omarwagih.github.io/gitter.

  8. A quantitative damage imaging technique based on enhanced CCRTM for composite plates using 2D scan

    NASA Astrophysics Data System (ADS)

    He, Jiaze; Yuan, Fuh-Gwo

    2016-10-01

    A two-dimensional (2D) non-contact areal scan system was developed to image and quantify impact damage in a composite plate using an enhanced zero-lag cross-correlation reverse-time migration (E-CCRTM) technique. The system comprises a single piezoelectric wafer mounted on the composite plate and a laser Doppler vibrometer (LDV) for scanning a region in the vicinity of the PZT to capture the scattered wavefield. The proposed damage imaging technique takes into account the amplitude, phase, geometric spreading, and all of the frequency content of the Lamb waves propagating in the plate; thus, a reflectivity coefficients of the delamination is calculated and potentially related to damage severity. Comparisons are made in terms of damage imaging quality between 2D areal scans and 1D line scans as well as between the proposed and existing imaging conditions. The experimental results show that the 2D E-CCRTM performs robustly when imaging and quantifying impact damage in large-scale composites using a single PZT actuator with a nearby areal scan using LDV.

  9. Dust Plate, Retina, Photograph: Imaging on Experimental Surfaces in Early Nineteenth-Century Physics.

    PubMed

    Ramalingam, Chitra

    2015-09-01

    This article explores the entangled histories of three imaging techniques in early nineteenth-century British physical science, techniques in which a dynamic event (such as a sound vibration or an electric spark) was made to leave behind a fixed trace on a sensitive surface. Three categories of "sensitive surface" are examined in turn: first, a metal plate covered in fine dust; second, the retina of the human eye; and finally, a surface covered with a light-sensitive chemical emulsion (a photographic plate). For physicists Michael Faraday and Charles Wheatstone, and photographic pioneer William Henry Fox Talbot, transient phenomena could be studied through careful observation and manipulation of the patterns wrought on these different surfaces, and through an understanding of how the imaging process unfolded through time. This exposes the often-ignored materiality and temporality of epistemic practices around nineteenth-century scientific images said to be "drawn by nature."

  10. Spatial resolution of imaging plate with flash X-rays and its utilization for radiography

    SciTech Connect

    Shaikh, A. M.; Romesh, C.; Kolage, T. S.; Sharma, Archana

    2015-06-24

    A flash X-ray source developed using pulsed electron accelerator with electron energy range of 400keV to 1030keV and a field emission cathode is characterized using X-ray imaging plates. Spatial resolution of the imaging system is measured using edge spread function fitted to data obtained from radiograph of Pb step wedge. A spatial resolution of 150±6 µm is obtained. The X-ray beam size is controlled by the anode-cathode configuration. Optimum source size of ∼13±2 mm diameter covering an area with intensity of ∼27000 PSL/mm{sup 2} is obtained on the imaging plate kept at a distance of ∼200 mm from the tip of the anode. It is used for recording radiographs of objects like satellite cable cutter, aero-engine turbine blade and variety of pyro-devices used in aerospace industry.

  11. Microchannel plate pinhole camera for 20 to 100 keV x-ray imaging

    SciTech Connect

    Wang, C.L.; Leipelt, G.R.; Nilson, D.G.

    1984-10-03

    We present the design and construction of a sensitive pinhole camera for imaging suprathermal x-rays. Our device is a pinhole camera consisting of four filtered pinholes and microchannel plate electron multiplier for x-ray detection and signal amplification. We report successful imaging of 20, 45, 70, and 100 keV x-ray emissions from the fusion targets at our Novette laser facility. Such imaging reveals features of the transport of hot electrons and provides views deep inside the target.

  12. Imaging flaws in thin metal plates using a magneto-optic device

    NASA Technical Reports Server (NTRS)

    Wincheski, B.; Prabhu, D. R.; Namkung, M.; Birt, E. A.

    1992-01-01

    An account is given of the capabilities of the magnetooptic/eddy-current imager (MEI) apparatus in the case of aging aircraft structure-type flaws in 2024-T3 Al alloy plates. Attention is given to images of cyclically grown fatigue cracks from rivetted joints in fabricated lap-joint structures, electrical discharge machining notches, and corrosion spots. Although conventional eddy-current methods could have been used, the speed and ease of MEI's use in these tests is unmatched by such means. Results are displayed in real time as a test piece is scanned, furnishing easily interpreted flaw images.

  13. Nonlinear ultrasonic imaging of thermal fatigue cracks of several tens nm gap in glass plates

    NASA Astrophysics Data System (ADS)

    Hertl, M.; Kawashima, K.; Sekino, K.; Yasui, H.; Aida, T.

    2015-10-01

    Thermal fatigue crack of which gap distance is several tens nm in glass plate is imaged by using an immersion higher harmonic imaging technique. Some parts of the thermal fatigue crack are clearly imaged by the third harmonic amplitude of the 3.5 MHz burst wave by angular incidence. For through-transmission mode across the crack face, the seventh harmonic of a through-thickness resonant frequency also visualizes the thermal fatigue crack. If spatial resolution will reach to a few micron meters, the technique could be applied for detection of disbonds in bonded wafers.

  14. Novel large format sealed tube microchannel plate detectors for Cherenkov timing and imaging

    NASA Astrophysics Data System (ADS)

    Siegmund, O. H. W.; McPhate, J. B.; Vallerga, J. V.; Tremsin, A. S.; Jelinsky, S. R.; Frisch, H. J.; Lappd Collaboration

    2011-05-01

    Large area (20×20 cm 2) sealed tube detectors using novel borosilicate glass microchannel plates, with bialkali photocathodes and strip-line readouts are being developed for Cherenkov light detection. Designs based on conventional sealed tubes with alumina brazed body construction and hot indium seals have been developed. Borosilicate glass substrates with 20 and 40 μm holes have been processed using atomic layer deposition to produce functional microchannel plates. Initial results for these in a 33 mm format show gain, imaging performance, pulse shape and lifetime characteristics that are similar to standard glass microchannel plates. Large area (20×20 cm 2) borosilicate glass substrates with 20 μm pores have also been made.

  15. Use of Optically Stimulated Luminescence Imaging Plates and Reader for Arms Control Applications

    SciTech Connect

    Miller, Steven D.; Tomeraasen, Paul L.; Burghard, Brion J.; Traub, Richard J.

    2001-07-05

    Optically Stimulated Luminescence (OSL) technology has been pioneered at the Pacific Northwest National Laboratory (PNNL) for applications in personnel radiation dosimetry and commercially has become highly successful in replacing older technologies such as Thermoluminescence Dosimeters (TLDs) and film. OSL phosphors are used to measure radiation exposure by illuminating them with light after ionizing radiation exposure and measuring the amount of light emitted by the OSL phosphor. By using a two-dimensional plate of OSL material and raster scanning a light beam across the OSL plate a radiation pattern or image can be measured. The Arms Control community requires an electrons-free medium to measure the attributes of extent and symmetry on Pu pits in storage containers. OSL technology, used in the two-dimensional imaging mode, provides a means to measure these attributes with exposure times on the order of an hour. A special OSL reader has been built by PNNL to measure OSL imaging plates with a size of 20 cm by 30 cm. The reader uses 10 light emitting diode clusters with 10 corresponding photomultiplier tubes to measure an OSL imaging plate in less than 5 minutes. The resolution of each of the 10 measurement assemblies is 1 square-centimeter. A collimator assembly employing a Venetian-blind type collimator is used in conjunction with the OSL film to image the Pu pit within the storage container. The output of the OSL reader is a two dimensional array of intensities that will be used with the appropriate information barriers to measure extent and symmetry. This device also clearly distinguishes the difference between a point source and a distributed source. Details of the OSL technology, OSL reader system, collimator design, and system performance will be presented.

  16. Juan de Fuca Plate Ridge-to-Trench Experiment: initial results from active source seismic imaging of the Juan de Fuca plate and Cascadia fore-arc (Invited)

    NASA Astrophysics Data System (ADS)

    Carbotte, S. M.; Canales, J.; Carton, H. D.; Han, S.; Gibson, J. C.; Janiszewski, H. A.; Horning, G.; Nedimovic, M. R.; Abers, G. A.; Trehu, A. M.

    2013-12-01

    Active source seismic data were acquired during the Juan de Fuca Ridge-to-Trench experiment (June-July 2012) to characterize the evolution and structure of the Juan de Fuca plate from formation at the ridge, through evolution in the plate interior, to subduction at the Cascadia trench. The survey provides plate-scale images of the sediments, crust, and shallowest mantle along two ridge-perpendicular transects, one extending from Axial seamount to the Oregon margin near Hydrate Ridge and the other from near Endeavour segment to Grays Harbor offshore Washington. In addition, a 450 km long trench-parallel line ~10 km seaward of the Cascadia deformation front was acquired to characterize variations in plate structure along the margin. Coincident long-streamer (8 km) multi-channel seismic (MCS) and wide-angle ocean bottom seismometer (OBS) data were collected along each transect. Using these data, our current investigations focus on the properties of the thick sediment blanket covering the Juan de Fuca plate and evidence for fluid flow at the deformation front, crustal structure within the plate interior and near the deformation front, and tracking the downgoing plate beneath the margin. Highlights include the discovery of numerous pockmarks on the seafloor providing evidence of active fluid flow up to 60 km west of the deformation front. Along the Oregon transect, a bright decollement horizon is imaged at ~1sec twtt above basement whereas at the Washington margin, protothrusts of the deformation front reach to the top of the oceanic crust. Variations in sediment properties are documented within the margin-parallel transect with changes in the stratigraphic level of decollement. While crustal thickness is quite uniform along the margin (~ 6 km), variations in crustal reflectivity and in shallowest mantle velocities are observed over ~30-50 km length scales that could be related to structural variations in the Cascadia subduction zone. Further landward, the top of the

  17. Nd:YAG Pulsed Laser based flaw imaging techniques for noncontact NDE of an aluminum plate

    NASA Astrophysics Data System (ADS)

    Park, Woong-Ki; Lee, Changgil; Park, Seunghee

    2012-04-01

    Recently, the longitudinal, shear and surface waves have been very widely used as a kind of ultrasonic wave exploration methods to identify internal defects of metallic structures. The ultrasonic wave-based non-destructive testing (NDT) is one of main non-destructive inspection techniques for a health assessment about nuclear power plant, aircraft, ships, and/or automobile manufacturing. In this study, a noncontact pulsed laser-based flaw imaging NDT technique is implemented to detect the damage of a plate-like structure and to identify the location of the damage. To achieve this goal, the Nd:YAG pulsed laser equipment is used to generate a guided wave and scans a specific area to find damage location. The Nd: YAG pulsed laser is used to generate Lamb wave and piezoelectric sensors are installed to measure structural responses. Ann aluminum plate is investigated to verify the effectiveness and the robustness of the proposed NDT approach. A notch is a target to detect, which is inflicted on the surface of an aluminum plate. The damagesensitive features are extracted by comparing the time of flight of the guided wave obtained from an acoustic emission (AE) sensor and make use of the flaw imaging techniques of the aluminum plate.

  18. The role of image design in communicating the plate tectonic model

    NASA Astrophysics Data System (ADS)

    Clark, S. K.

    2009-12-01

    As the unifying concept of the geosciences, the plate tectonic model is arguably the most important concept for students to understand about the Earth. The scale of plate tectonic processes is far beyond the everyday scale of human lives. Maps and schematic images within textbooks, on-line, or on television are the only access that most lay people, students, and even geologists will ever have to these inherently intangible processes. This means that images play a critical role in communicating aspects of plate tectonics and in developing conceptual models of these earth-scale processes to both experts and novices. In this study, non-science majors to geoscience faculty answered questions about a simplified version of a well-known schematic cross-section that illustrates various plate tectonic processes. Findings from questionnaires and interviews, including eye-tracking data, reveal the differences in how experts and novices visually inspect and interpret the cross-section. Findings include: Experts will focus on the relevant aspects of the image and may completely filter and dismiss aspects of the image they deem irrelevant. However, those same, irrelevant aspects can pose significant distractions to novices, and may mislead novices either by creating new misconceptions or supporting prior misconceptions. Two examples of commonly seen and possibly distracting aspects in cross sections of the plate tectonic model are a red, orange, or yellow asthenosphere under a gray lithosphere, and subducting slabs that terminate in the asthenosphere. The color scheme supports a misconception held by some of a hot, liquid mantle. Subducting slabs that either terminate abruptly or fade away are frequently interpreted to be melting at the “tip”. These findings support research that has clearly indicated that experts attend to relevant aspects of visual stimuli whereas novices do not. Images designed for experts may simply be too confusing for novices to focus on the salient

  19. High resolution, two-dimensional imaging, microchannel plate detector for use on a sounding rocket experiment

    NASA Technical Reports Server (NTRS)

    Bush, Brett C.; Cotton, Daniel M.; Siegmund, Oswald H.; Chakrabarti, Supriya; Harris, Walter; Clarke, John

    1991-01-01

    We discuss a high resolution microchannel plate (MCP) imaging detector to be used in measurements of Doppler-shifted hydrogen Lyman-alpha line emission from Jupiter and the interplanetary medium. The detector is housed in a vacuum-tight stainless steel cylinder (to provide shielding from magnetic fields) with a MgF2 window. Operating at nominal voltage, the four plate configuration provides a gain of 1.2 x 10 exp 7 electrons per incident photon. The wedge-and-strip anode has two-dimensional imaging capabilities, with a resolution of 40 microns FWHM over a one centimeter diameter area. The detector has a high quantum efficiency while retaining a low background rate. A KBr photocathode is used to enhance the quantum efficiency of the bare MCPs to a value of 35 percent at Lyman-alpha.

  20. High resolution, two-dimensional imaging, microchannel plate detector for use on a sounding rocket experiment

    NASA Technical Reports Server (NTRS)

    Bush, Brett C.; Cotton, Daniel M.; Siegmund, Oswald H.; Chakrabarti, Supriya; Harris, Walter; Clarke, John

    1991-01-01

    We discuss a high resolution microchannel plate (MCP) imaging detector to be used in measurements of Doppler-shifted hydrogen Lyman-alpha line emission from Jupiter and the interplanetary medium. The detector is housed in a vacuum-tight stainless steel cylinder (to provide shielding from magnetic fields) with a MgF2 window. Operating at nominal voltage, the four plate configuration provides a gain of 1.2 x 10 exp 7 electrons per incident photon. The wedge-and-strip anode has two-dimensional imaging capabilities, with a resolution of 40 microns FWHM over a one centimeter diameter area. The detector has a high quantum efficiency while retaining a low background rate. A KBr photocathode is used to enhance the quantum efficiency of the bare MCPs to a value of 35 percent at Lyman-alpha.

  1. Imaging plate for time-resolved x-ray measurements (invited)

    NASA Astrophysics Data System (ADS)

    Amemiya, Yoshiyuki; Kishimoto, Shunji; Matsushita, Tadashi; Satow, Yoshinori; Ando, Masami

    1989-07-01

    Two apparatus have been developed for time-resolved measurements of x-ray diffraction patterns using an imaging plate detector. The first one is based on a cinema method which permits up to 40 exposures of a two-dimensional x-ray pattern (100×108 mm2) with a 0.3-s time resolution. The second one works as a 200-mm-long linear detector which enables a time resolution of 23 μs for a duration of up to 46 ms, based on a streak-camera method. These apparatus have no count rate limitation, a high detective quantum efficiency (more than 80% for 8-20 keV), a 1:105 dynamic range in x-ray intensity and a spatial resolution of 150 μm (FWHM) due to the performance of the imaging plate.

  2. Chip-based optical microscopy for imaging membrane sieve plates of liver scavenger cells

    NASA Astrophysics Data System (ADS)

    Helle, Øystein I.; Øie, Cristina I.; McCourt, Peter; Ahluwalia, Balpreet S.

    2015-08-01

    The evanescent field on top of optical waveguides is used to image membrane network and sieve-plates of liver endothelial cells. In waveguide excitation, the evanescent field is dominant only near the surface (~100-150 nm) providing a default optical sectioning by illuminating fluorophores in close proximity to the surface and thus benefiting higher signal-to-noise ratio. The sieve plates of liver sinusoidal endothelial cells are present on the cell membrane, thus near-field waveguide chip-based microscopy configuration is preferred over epi-fluorescence. The waveguide chip is compatible with optical fiber components allowing easy multiplexing to different wavelengths. In this paper, we will discuss the challenges and opportunities provided by integrated optical microscopy for imaging cell membranes.

  3. Ultrasonic Imaging and Theoretical Prediction of Orthotropic Plate Stiffness in all Planar Directions

    SciTech Connect

    Telschow, Kenneth Louis; Deason, Vance Albert; Mukdadi, O.; Datta, S. K.

    2000-07-01

    Exact and approximate theoretical analysis of the wavelengths of plate wave mode propagation in all planar directions for the dispersive antisymmetric Lamb wave mode are compared with measurements from a laser ultrasonic imaging approach that records the out of plane ultrasonic motion over a large area in a single frame without scanning. Good agreement is demonstrated, based on independent determination of the elastic constants, for two different types of paper.

  4. Surface-Wave Imaging of the Juan de Fuca Plate and Cascadia Subduction Zone

    NASA Astrophysics Data System (ADS)

    Janiszewski, H. A.; Gaherty, J. B.; Abers, G. A.

    2015-12-01

    The Juan de Fuca plate over the past four years has been the location of the onshore-offshore Cascadia Initiative (CI) array. These data present a rare opportunity to image the evolution of the crust and mantle of an entire plate from the ridge through the subduction zone. The Cascadia subduction zone is capable of up to a M9 megathrust earthquake; seismic imaging provides a major constraint on the thermal structure and hydration state of the plate, which in turn constrain models of seismogenesis. We utilize a multi-channel cross-correlation analysis to estimate the phase-velocity of Rayleigh waves traversing the CI from teleseismic earthquakes recorded over the first three years of the deployment, to image the structure of the Juan de Fuca plate and the Cascadia arc and forearc. Our initial results are dominated by the transition from high-velocity oceanic to low-velocity continental lithosphere across the margin, high velocities in the region of the subducting slab, and low velocities beneath the arc. All of these areas produce reasonable standard deviation in the velocity estimates. These images confirm the robustness of our methodology, despite the different noise characteristics of the onshore sites and the ocean bottom seismometers (OBS). Among the OBS sites there are additional differences between those deployed in deep water on oceanic crust and those in shallow water on the continental shelf. Compliance and tilt corrections have a significant effect at some stations and are taken into account accordingly. These results will be combined with recent results from offshore receiver functions and estimates of short-period Rayleigh wave dispersion from ambient noise to constrain the crust and mantle structure in a joint inversion.

  5. Plate Scattering Visualization: Images, Near Fields, Currents, and Far Field Patterns

    NASA Technical Reports Server (NTRS)

    Shaeffer, John; Hom, Kam

    2004-01-01

    This paper presents a case study of a simple yet robust target for demonstration of the EM visualization process. A five lambda square plate exhibits many scattering mechanisms depending on excitation angle and polarization: specular scattering, leading and trailing edge diffraction, traveling wave, and edge wave scattering. Bistatic k space radiation images, currents maps, and near scattered / total fields are examined for each of these scattering mechanisms.

  6. Spatio-temporal mapping of plate boundary faults in California using geodetic imaging

    USGS Publications Warehouse

    Donnellan, Andrea; Arrowsmith, Ramon; DeLong, Stephen B.

    2017-01-01

    The Pacific–North American plate boundary in California is composed of a 400-km-wide network of faults and zones of distributed deformation. Earthquakes, even large ones, can occur along individual or combinations of faults within the larger plate boundary system. While research often focuses on the primary and secondary faults, holistic study of the plate boundary is required to answer several fundamental questions. How do plate boundary motions partition across California faults? How do faults within the plate boundary interact during earthquakes? What fraction of strain accumulation is relieved aseismically and does this provide limits on fault rupture propagation? Geodetic imaging, broadly defined as measurement of crustal deformation and topography of the Earth’s surface, enables assessment of topographic characteristics and the spatio-temporal behavior of the Earth’s crust. We focus here on crustal deformation observed with continuous Global Positioning System (GPS) data and Interferometric Synthetic Aperture Radar (InSAR) from NASA’s airborne UAVSAR platform, and on high-resolution topography acquired from lidar and Structure from Motion (SfM) methods. Combined, these measurements are used to identify active structures, past ruptures, transient motions, and distribution of deformation. The observations inform estimates of the mechanical and geometric properties of faults. We discuss five areas in California as examples of different fault behavior, fault maturity and times within the earthquake cycle: the M6.0 2014 South Napa earthquake rupture, the San Jacinto fault, the creeping and locked Carrizo sections of the San Andreas fault, the Landers rupture in the Eastern California Shear Zone, and the convergence of the Eastern California Shear Zone and San Andreas fault in southern California. These examples indicate that distribution of crustal deformation can be measured using interferometric synthetic aperture radar (InSAR), Global Navigation

  7. Imaging IGF-I uptake in growth plate cartilage using in vivo multiphoton microscopy.

    PubMed

    Serrat, Maria A; Ion, Gabriela

    2017-08-10

    Bones elongate through endochondral ossification in cartilaginous growth plates located at ends of primary long bones. Linear growth ensues from a cascade of biochemical signals initiated by actions of systemic and local regulators on growth plate chondrocytes. Although cellular processes are well defined, there is a fundamental gap in understanding how growth regulators are physically transported from surrounding blood vessels into and through dense, avascular cartilage matrix. Intravital imaging using in vivo multiphoton microscopy is one promising strategy to overcome this barrier by quantitatively tracking molecular delivery to cartilage from the vasculature in real time. We previously used in vivo multiphoton imaging to show that hindlimb heating increases vascular access of large molecules to growth plates using 10-, 40-, and 70 kDa dextran tracers. In order to comparatively evaluate transport of similarly sized physiological regulators, we developed and validated methods for measuring uptake of biologically active IGF-I into proximal tibial growth plates of live 5-week old mice. We demonstrate that fluorescently labeled IGF-I (8.2 kDa) is readily taken up in the growth plate and localizes to chondrocytes. Bioactivity tests performed on cultured metatarsal bones confirmed that the labeled protein is functional, assessed by phosphorylation of its signaling kinase Akt. This methodology, which can be broadly applied to many different proteins and tissues, is relevant for understanding factors that affect delivery of biologically relevant molecules to the skeleton in real time. Results may lead to the development of drug-targeting strategies to treat a wide range of bone and cartilage pathologies. Copyright © 2017, Journal of Applied Physiology.

  8. Note: spatial resolution of Fuji BAS-TR and BAS-SR imaging plates.

    PubMed

    Fiksel, G; Marshall, F J; Mileham, C; Stoeckl, C

    2012-08-01

    The spatial resolution of two types of imaging plates, Fuji BAS-TR and Fuji BAS-SR, has been measured using a knife-edge x-ray source of 8-keV Cu K(α) radiation. The values for the spatial resolution, defined as the distance between 10% and 90% levels of the edge spread function, are 94 μm and 109 μm, respectively. The resolution values are important for quantitative analysis of x-ray and particle imaging and spectroscopic diagnostics.

  9. Note: Spatial resolution of Fuji BAS-TR and BAS-SR imaging plates

    NASA Astrophysics Data System (ADS)

    Fiksel, G.; Marshall, F. J.; Mileham, C.; Stoeckl, C.

    2012-08-01

    The spatial resolution of two types of imaging plates, Fuji BAS-TR and Fuji BAS-SR, has been measured using a knife-edge x-ray source of 8-keV Cu Kα radiation. The values for the spatial resolution, defined as the distance between 10% and 90% levels of the edge spread function, are 94 μm and 109 μm, respectively. The resolution values are important for quantitative analysis of x-ray and particle imaging and spectroscopic diagnostics.

  10. Note: Spatial resolution of Fuji BAS-TR and BAS-SR imaging plates

    SciTech Connect

    Fiksel, G.; Marshall, F. J.; Mileham, C.; Stoeckl, C.

    2012-08-15

    The spatial resolution of two types of imaging plates, Fuji BAS-TR and Fuji BAS-SR, has been measured using a knife-edge x-ray source of 8-keV Cu K{sub {alpha}} radiation. The values for the spatial resolution, defined as the distance between 10% and 90% levels of the edge spread function, are 94 {mu}m and 109 {mu}m, respectively. The resolution values are important for quantitative analysis of x-ray and particle imaging and spectroscopic diagnostics.

  11. A New Parametric Kernel Estimation Technique for License Plate Image De-blurring

    NASA Astrophysics Data System (ADS)

    Rao, P. S. Prashanth; Muthu, Rajesh Kumar

    2017-09-01

    A recognizable license plate in a picture taken by a traffic monitoring system is crucial for identifying the vehicles involved in traffic violations. In the image of a vehicle taken by a surveillance camera, the license plate is often blurred due to fast motion and cannot be recognized by the human eye. In this type of blurring, the blur kernel can be seen to be a linear uniform convolution parametrically described by its angle and length. In this paper, we introduce a new estimation technique to determine this kernel accurately in order to improve our de-blurred result. We use the Hough transform in estimating the direction in which the image is blurred. To determine the extent of the blur in that direction, we employ a new method involving the cepstrum of the blurred image. We compare the performance of our method to that of other recent blind de-blurring techniques. These comparisons show that our proposed scheme can handle significant blur in the captured image to give a good output image.

  12. Calibrating image plate sensitivity in the 700 to 5000 eV spectral energy range

    NASA Astrophysics Data System (ADS)

    Haugh, Michael J.; Lee, Joshua; Romano, Edward; Schneider, Marilyn

    2013-09-01

    This paper describes a method to calibrate image plate sensitivity for use in the low energy spectral range. Image plates, also known as photostimulable luminescence (PSL) detectors, have often proved to be a valuable tool as a detector for plasma physics studies. Their advantages of large dynamic range, high stopping power, and resistance to neutron damage sometimes outweigh the problems of limited resolution and the remote processing required. The neutron damage resistance is required when the X-ray source is producing a high neutron flux. The Static X-ray Imager (SXI) is a key diagnostic on the National Ignition Facility (NIF) target chamber at LLNL for use in determining the symmetry of the laser beams. The SXI is essential to proper interpretation of the data from the Dante diagnostic to determine the X-ray radiation temperature. It is comprised of two diagnostics located at the top and the bottom of the target chamber. The usual detector is a large array CCD camera. For shots giving high yields of neutrons, the camera would not only be blinded by the neutrons, it would be damaged. To get around this problem, an image plate (IP) is used as the detector. The NIF application covers the energy range from 700 to 5000 eV. The type of image plates typically used for plasma physics are the Fuji BAS-MS, BAS-SR, and BAS-TR models. All models consist of an X-ray sensitive material made of BaF(Br,I):Eu2+ embedded in a plastic binder. X-rays incident on the phosphor ionize the Eu 2+ producing Eu3+ and free electrons that are trapped in lattice defects (F-centers) produced by the absence of halogen ions in the BaF2 crystal. An image plate readout scanner irradiates the IP with a red laser causing reduction of the Eu3+ and emission of a blue photon. The photon is collected using a photomultiplier and digitized to make an electronic image. Image plates are cleared of all F-centers by putting them under a bright light for about 10 minutes. They are then ready for producing a

  13. Interlaced zone plate optics for hard X-ray imaging in the 10 nm range

    DOE PAGES

    Mohacsi, Istvan; Vartiainen, Ismo; Rosner, Benedikt; ...

    2017-03-08

    Multi-keV X-ray microscopy has been particularly successful in bridging the resolution gap between optical and electron microscopy. However, resolutions below 20 nm are still considered challenging, as high throughput direct imaging methods are limited by the availability of suitable optical elements. In order to bridge this gap, we present a new type of Fresnel zone plate lenses aimed at the sub-20 and the sub-10 nm resolution range. By extending the concept of double-sided zone plate stacking, we demonstrate the doubling of the effective line density and thus the resolution and provide large aperture, single- chip optical devices with 15 andmore » 7 nm smallest zone widths. The detailed characterization of these lenses shows excellent optical properties with focal spots down to 7.8 nm. Furthermore, beyond wave front characterization, the zone plates also excel in typical imaging scenarios, verifying their resolution close to their diffraction limited optical performance.« less

  14. Imaging and quantitative analysis of tritium-labelled cells in lymphocyte proliferation assays using microchannel plate detectors originally developed for X-ray astronomy.

    PubMed

    Lees, J E; Hales, J M

    2001-01-01

    Microchannel plate detectors have been used in many astronomical X-ray telescopes. Recently we have begun to use similar detectors to image electron emission from radiolabelled biological assays. Here we show how a microchannel plate (MCP) detector can be used to image tritium uptake in T lymphocyte proliferation assays. Quantitative analysis using the MCP detector has the same sensitivity and speed as conventional liquid scintillation counter (LSC) analysis whilst obviating the need for scintillation fluid. In addition the system permits the imaging of whole plate harvests from a range of plate sizes. Here we present data obtained with 96-well plates and Terasaki plates.

  15. Coherent x-ray diffraction imaging of paint pigmentparticles by scanning a phase plate modulator

    SciTech Connect

    Chu Y. S.; Chen B.; Zhang F.; Berenguer F.; Bean R.; Kewish C.; Vila-Comamala J.; Rodenburg J.; Robinson I.

    2011-10-19

    We have implemented a coherent x-ray diffraction imaging technique that scans a phase plate to modulate wave-fronts of the x-ray beam transmitted by samples. The method was applied to measure a decorative alkyd paint containing iron oxide red pigment particles. By employing an iterative algorithm for wave-front modulation phase retrieval, we obtained an image of the paint sample that shows the distribution of the pigment particles and is consistent with the result obtained from a transmission x-ray microscope. The technique has been experimentally proven to be a feasible coherent x-ray imaging method with about 120 nm spatial resolution and was shown to work well with industrially relevant specimens.

  16. Fluorescence microscopy imaging with a Fresnel zone plate array based optofluidic microscope

    PubMed Central

    Han, Chao; Lee, Lap Man; Yang, Changhuei

    2013-01-01

    We report the implementation of an on-chip microscope system, termed fluorescence optofluidic microscope (FOFM), which is capable of fluorescence microscopy imaging of samples in fluid media. The FOFM employs an array of Fresnel zone plates (FZP) to generate an array of focused light spots within a microfluidic channel. As a sample flows through the channel and across the array of focused light spots, the fluorescence emissions are collected by a filter-coated CMOS sensor, which serves as the channel's floor. The collected data can then be processed to render fluorescence microscopy images at a resolution determined by the focused light spot size (experimentally measured as 0.65 μm FWHM). In our experiments, our established resolution was 1.0 μm due to Nyquist criterion consideration. As a demonstration, we show that such a system can be used to image the cell nuclei stained by Acridine Orange and cytoplasm labeled by Qtracker®. PMID:21935556

  17. Thin plate spline feature point matching for organ surfaces in minimally invasive surgery imaging

    NASA Astrophysics Data System (ADS)

    Lin, Bingxiong; Sun, Yu; Qian, Xiaoning

    2013-03-01

    Robust feature point matching for images with large view angle changes in Minimally Invasive Surgery (MIS) is a challenging task due to low texture and specular reflections in these images. This paper presents a new approach that can improve feature matching performance by exploiting the inherent geometric property of the organ surfaces. Recently, intensity based template image tracking using a Thin Plate Spline (TPS) model has been extended for 3D surface tracking with stereo cameras. The intensity based tracking is also used here for 3D reconstruction of internal organ surfaces. To overcome the small displacement requirement of intensity based tracking, feature point correspondences are used for proper initialization of the nonlinear optimization in the intensity based method. Second, we generate simulated images from the reconstructed 3D surfaces under all potential view positions and orientations, and then extract feature points from these simulated images. The obtained feature points are then filtered and re-projected to the common reference image. The descriptors of the feature points under different view angles are stored to ensure that the proposed method can tolerate a large range of view angles. We evaluate the proposed method with silicon phantoms and in vivo images. The experimental results show that our method is much more robust with respect to the view angle changes than other state-of-the-art methods.

  18. Conversion from Film to Image Plates for Transfer Method Neutron Radiography of Nuclear Fuel

    NASA Astrophysics Data System (ADS)

    Craft, Aaron E.; Papaioannou, Glen C.; Chichester, David L.; Williams, Walter J.

    This paper summarizes efforts to characterize and qualify a computed radiography (CR) system for neutron radiography of irradiated nuclear fuel at Idaho National Laboratory (INL). INL has multiple programs that are actively developing, testing, and evaluating new nuclear fuels. Irradiated fuel experiments are subjected to a number of sequential post-irradiation examination techniques that provide insight into the overall behavior and performance of the fuel. One of the first and most important of these exams is neutron radiography, which provides more comprehensive information about the internal condition of irradiated nuclear fuel than any other non-destructive technique to date. Results from neutron radiography are often the driver for subsequent examinations of the PIE program. Features of interest that can be evaluated using neutron radiography include irradiation-induced swelling, isotopic and fuel-fragment redistribution, plate deformations, and fuel fracturing. The NRAD currently uses the foil-film transfer technique with film for imaging fuel. INL is pursuing multiple efforts to advance its neutron imaging capabilities for evaluating irradiated fuel and other applications, including conversion from film to CR image plates. Neutron CR is the current state-of-the-art for neutron imaging of highly-radioactive objects. Initial neutron radiographs of various types of nuclear fuel indicate that radiographs can be obtained of comparable image quality currently obtained using film. This paper provides neutron radiographs of representative irradiated fuel pins along with neutron radiographs of standards that informed the qualification of the neutron CR system for routine use. Additionally, this paper includes evaluations of some of the CR scanner parameters and their effects on image quality.

  19. Anatomy of the western Java plate interface from depth-migrated seismic images

    USGS Publications Warehouse

    Kopp, H.; Hindle, D.; Klaeschen, D.; Oncken, O.; Reichert, C.; Scholl, D.

    2009-01-01

    Newly pre-stack depth-migrated seismic images resolve the structural details of the western Java forearc and plate interface. The structural segmentation of the forearc into discrete mechanical domains correlates with distinct deformation styles. Approximately 2/3 of the trench sediment fill is detached and incorporated into frontal prism imbricates, while the floor sequence is underthrust beneath the d??collement. Western Java, however, differs markedly from margins such as Nankai or Barbados, where a uniform, continuous d??collement reflector has been imaged. In our study area, the plate interface reveals a spatially irregular, nonlinear pattern characterized by the morphological relief of subducted seamounts and thicker than average patches of underthrust sediment. The underthrust sediment is associated with a low velocity zone as determined from wide-angle data. Active underplating is not resolved, but likely contributes to the uplift of the large bivergent wedge that constitutes the forearc high. Our profile is located 100 km west of the 2006 Java tsunami earthquake. The heterogeneous d??collement zone regulates the friction behavior of the shallow subduction environment where the earthquake occurred. The alternating pattern of enhanced frictional contact zones associated with oceanic basement relief and weak material patches of underthrust sediment influences seismic coupling and possibly contributed to the heterogeneous slip distribution. Our seismic images resolve a steeply dipping splay fault, which originates at the d??collement and terminates at the sea floor and which potentially contributes to tsunami generation during co-seismic activity. ?? 2009 Elsevier B.V.

  20. Imaging the Juan de Fuca plate beneath southern Oregon using teleseismic P wave residuals

    USGS Publications Warehouse

    Harris, R.A.; Iyer, H.M.; Dawson, P.B.

    1991-01-01

    Images the Juan de Fuca plate in southern Oregon using seismic tomography. P wave travel time residuals from a 366-km-long seismic array operated in southern Oregon in 1982 are inverted. The southeast striking array extended from the Coast ranges to the Modoc Plateau and crossed the High Cascades at Crater Lake, Oregon. Three features under the array were imaged: one high-velocity zone and two low-velocity zones. The high-velocity zone is 3-4% faster than the surrounding upper mantle. It dips steeply at 65?? to the east beneath the Cascade Range and extends down to at least 200 km. It is proposed that this high-velocity feature is subducted Juan de Fuca plate. Two low-velocity zones were also imaged, both of which are 3-4% slower than the surrounding earth structure. The southeastern low-velocity zone may be caused by partially molten crust underlying the Crater Lake volcano region. -from Authors

  1. Big data analytics in hyperspectral imaging for detection of microbial colonies on agar plates (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Yoon, Seung-Chul; Park, Bosoon; Lawrence, Kurt C.

    2017-05-01

    Various types of optical imaging techniques measuring light reflectivity and scattering can detect microbial colonies of foodborne pathogens on agar plates. Until recently, these techniques were developed to provide solutions for hypothesis-driven studies, which focused on developing tools and batch/offline machine learning methods with well defined sets of data. These have relatively high accuracy and rapid response time because the tools and methods are often optimized for the collected data. However, they often need to be retrained or recalibrated when new untrained data and/or features are added. A big-data driven technique is more suitable for online learning of new/ambiguous samples and for mining unknown or hidden features. Although big data research in hyperspectral imaging is emerging in remote sensing and many tools and methods have been developed so far in many other applications such as bioinformatics, the tools and methods still need to be evaluated and adjusted in applications where the conventional batch machine learning algorithms were dominant. The primary objective of this study is to evaluate appropriate big data analytic tools and methods for online learning and mining of foodborne pathogens on agar plates. After the tools and methods are successfully identified, they will be applied to rapidly search big color and hyperspectral image data of microbial colonies collected over the past 5 years in house and find the most probable colony or a group of colonies in the collected big data. The meta-data, such as collection time and any unstructured data (e.g. comments), will also be analyzed and presented with output results. The expected results will be novel, big data-driven technology to correctly detect and recognize microbial colonies of various foodborne pathogens on agar plates.

  2. A Bremsstrahlung Spectrometer using k-edge and Differential Filters with Image plate dosimeters

    SciTech Connect

    Chen, C; Mackinnon, A; Beg, F; Chen, H; Key, M; King, J A; Link, A; MacPhee, A; Patel, P; Porkolab, M; Stephens, R; VanWoerkom, L; Akli, K; Freeman, R

    2008-05-02

    A Bremsstrahlung spectrometer using k-edge and differential filtering has been used with Image Plate dosimeters to measure the x-ray fluence from short-pulse laser/target interactions. An electron spectrometer in front of the Bremsstrahlung spectrometer deflects electrons from the x-ray line of sight and simultaneously measures the electron spectrum. The response functions were modeled with the Monte Carlo code Integrated Tiger Series 3.0 and the dosimeters calibrated with radioactive sources. Electron distributions with slope temperatures in the MeV range are inferred from the Bremsstrahlung spectra.

  3. A Bremsstrahlung spectrometer using k-edge and differential filters with image plate dosimeters

    SciTech Connect

    Chen, C. D.; Porkolab, M.; King, J. A.; Beg, F. N.; Key, M. H.; Chen, H.; Mackinnon, A. J.; MacPhee, A. G.; Patel, P. K.; Akli, K. U.; Stephens, R. B.; Freeman, R. R.; Link, A.; Van Woerkom, L. D.

    2008-10-15

    A Bremsstrahlung spectrometer using k-edge and differential filtering has been used with image plate dosimeters to measure the x-ray fluence from short-pulse laser/target interactions. An electron spectrometer in front of the Bremsstrahlung spectrometer deflects electrons from the x-ray line of sight and simultaneously measures the electron spectrum. The response functions were modeled with the Monte Carlo code INTEGRATED TIGER SERIES 3.0 and the dosimeters calibrated with radioactive sources. An electron distribution with a slope temperature of 1.3 MeV is inferred from the Bremsstrahlung spectra.

  4. Towards multi-order hard X-ray imaging with multilayer zone plates.

    PubMed

    Osterhoff, Markus; Eberl, Christian; Döring, Florian; Wilke, Robin N; Wallentin, Jesper; Krebs, Hans-Ulrich; Sprung, Michael; Salditt, Tim

    2015-02-01

    This article describes holographic imaging experiments using a hard X-ray multilayer zone plate (MZP) with an outermost zone width of 10 nm at a photon energy of 18 keV. An order-sorting aperture (OSA) is omitted and emulated during data analysis by a 'software OSA'. Scanning transmission X-ray microscopy usually carried out in the focal plane is generalized to the holographic regime. The MZP focus is characterized by a three-plane phase-retrieval algorithm to an FWHM of 10 nm.

  5. Measurement of activity distribution using photostimulable phosphor imaging plates in decommissioned 10 MV medical linear accelerator.

    PubMed

    Fujibuchi, Toshioh; Yonai, Shunsuke; Yoshida, Masahiro; Sakae, Takeji; Watanabe, Hiroshi; Abe, Yoshihisa; Itami, Jun

    2014-08-01

    Photonuclear reactions generate neutrons in the head of the linear accelerator. Therefore, some parts of the linear accelerator can become activated. Such activated materials must be handled as radioactive waste. The authors attempted to investigate the distribution of induced radioactivity using photostimulable phosphor imaging plates. Autoradiographs were produced from some parts of the linear accelerator (the target, upper jaw, multileaf collimator and shielding). The levels of induced radioactivity were confirmed to be non-uniform within each part from the autoradiographs. The method was a simple and highly sensitive approach to evaluating the relative degree of activation of the linear accelerators, so that appropriate materials management procedures can be carried out.

  6. Far-field subwavelength imaging for ultrasonic elastic waves in a plate using an elastic hyperlens

    NASA Astrophysics Data System (ADS)

    Lee, Hyung Jin; Kim, Hoe Woong; Kim, Yoon Young

    2011-06-01

    Subwavelength imaging was experimentally performed for ultrasonic elastic waves by using an angularly stratified plat, an elastic plate hyperlens. It consists of alternating layers of aluminum and air, exhibiting a large contrast in elastic stiffness. A specially configured experimental setup is used to locate two sources within half the wavelength at 100 kHz. To explain the observed phenomenon, the homogenization of the elasticity coefficients of the stratified structure is employed. Because of the strong cylindrical anisotropy, an equifrequency contour becomes nearly flat along the angular wave vector so that evanescent waves involved with high angular resolution are converted to propagating waves.

  7. Reflective and transmissive CR ScanHead technology on needle image plates

    NASA Astrophysics Data System (ADS)

    Frankenberger, Jorg; Mair, Stephan; Herrmann, Clemens; Lamotte, Johan; Fasbender, Robert

    2005-04-01

    The image quality of needle-image-plate (NIP) Computed Radiography (CR) scanners based on ScanHead technology was optimized. In order to get the best image quality for different applications, the influence of the phosphor layer thickness on the detective quantum efficiency (DQE) for different beam qualities was investigated. We compared a cassette-based, reflective CR-NIP-scanner to a new, transmissive flat-panel CR scanner with fixed, mounted NIP. The image quality was analyzed by DQE- and modulation transfer function (MTF) measurements supported by an observer study. The NIP systems reached DQE values up to three times higher than that of high-quality, state of the art CR scanners independent of the scanning principle. This allows a dose reduction by a factor of two to three without loss of image quality for both scanning systems. For high tube voltages, the variation of the phosphor layer thickness results in a DQE maximum at relatively large thicknesses. For lower tube voltages the DQE is less dependent on the layer thickness, reaching excellent values already at considerably lower thicknesses. Consequently, CR scanners can be adapted to different applications by using NIPs with different thicknesses. This could be easily realized for the cassette based system, but not for the flat-panel system with fixed IP. The latter demands a compromise with respect to the phosphor thickness, to yield superior image quality for all applications.

  8. Cranial fixation plates in cerebral magnetic resonance imaging: a 3 and 7 Tesla in vivo image quality study.

    PubMed

    Chen, Bixia; Schoemberg, Tobias; Kraff, Oliver; Dammann, Philipp; Bitz, Andreas K; Schlamann, Marc; Quick, Harald H; Ladd, Mark E; Sure, Ulrich; Wrede, Karsten H

    2016-06-01

    This study assesses and quantifies impairment of postoperative magnetic resonance imaging (MRI) at 7 Tesla (T) after implantation of titanium cranial fixation plates (CFPs) for neurosurgical bone flap fixation. The study group comprised five patients who were intra-individually examined with 3 and 7 T MRI preoperatively and postoperatively (within 72 h/3 months) after implantation of CFPs. Acquired sequences included T1-weighted magnetization-prepared rapid-acquisition gradient-echo (MPRAGE), T2-weighted turbo-spin-echo (TSE) imaging, and susceptibility-weighted imaging (SWI). Two experienced neurosurgeons and a neuroradiologist rated image quality and the presence of artifacts in consensus reading. Minor artifacts occurred around the CFPs in MPRAGE and T2 TSE at both field strengths, with no significant differences between 3 and 7 T. In SWI, artifacts were accentuated in the early postoperative scans at both field strengths due to intracranial air and hemorrhagic remnants. After resorption, the brain tissue directly adjacent to skull bone could still be assessed. Image quality after 3 months was equal to the preoperative examinations at 3 and 7 T. Image quality after CFP implantation was not significantly impaired in 7 T MRI, and artifacts were comparable to those in 3 T MRI.

  9. Imaging the Juan de Fuca subduction plate using 3D Kirchoff Prestack Depth Migration

    NASA Astrophysics Data System (ADS)

    Cheng, C.; Bodin, T.; Allen, R. M.; Tauzin, B.

    2014-12-01

    We propose a new Receiver Function migration method to image the subducting plate in the western US that utilizes the US array and regional network data. While the well-developed CCP (common conversion point) poststack migration is commonly used for such imaging; our method applies a 3D prestack depth migration approach. The traditional CCP and post-stack depth mapping approaches implement the ray tracing and moveout correction for the incoming teleseismic plane wave based on a 1D earth reference model and the assumption of horizontal discontinuities. Although this works well in mapping the reflection position of relatively flat discontinuities (such as the Moho or the LAB), CCP is known to give poor results in the presence of lateral volumetric velocity variations and dipping layers. Instead of making the flat layer assumption and 1D moveout correction, seismic rays are traced in a 3D tomographic model with the Fast Marching Method. With travel time information stored, our Kirchoff migration is done where the amplitude of the receiver function at a given time is distributed over all possible conversion points (i.e. along a semi-elipse) on the output migrated depth section. The migrated reflectors will appear where the semicircles constructively interfere, whereas destructive interference will cancel out noise. Synthetic tests show that in the case of a horizontal discontinuity, the prestack Kirchoff migration gives similar results to CCP, but without spurious multiples as this energy is stacked destructively and cancels out. For 45 degree and 60 degree dipping discontinuities, it also performs better in terms of imaging at the right boundary and dip angle. This is especially useful in the Western US case, beneath which the Juan de Fuca plate subducted to ~450km with a dipping angle that may exceed 50 degree. While the traditional CCP method will underestimate the dipping angle, our proposed imaging method will provide an accurate 3D subducting plate image without

  10. A new technique for measuring the concentrations of airborne radon progeny by using an imaging plate.

    PubMed

    Zhang, H; Chen, B; Zhao, C; Zhuo, W

    2012-11-01

    A new technique was developed for measuring the concentrations of airborne radon progeny by using an imaging plate (IP). The concentrations of radon progeny collected on the sampling filter were measured with the IP at 2-5-, 6-20- and 21-30-min intervals after sampling, and the alpha disintegrations were automatically counted by a self-developed image analysis software. To reduce the overlapping impact on alpha counts, a plastic separator with a 0.5-mm thickness was set between the sampling filter and the IP. The lower limit of detection for the equilibrium equivalent concentration of radon was estimated to be ∼3.5 Bq m(-3) for a 10-min sampling at 10 l min(-1). Comparison experiments showed that results measured with the new technique were well consistent with those measured with the alpha spectrometer. It indicates that the new technique is a useful method for accurate measurements of airborne radon progeny concentrations.

  11. Nanosecond-gating properties of proximity-focused microchannel-plate image intensifiers

    NASA Astrophysics Data System (ADS)

    King, N. S. P.; Yates, G. J.; Jaramillo, S. A.; Ogle, J. W.

    Some fundamental properties of 18 mm-diam gated proximity focussed microchannel plate (MCP) image intensifiers used as fast image shutters in the 1 to 10 ns range were identified and studied. Light pulses from a modelocked dye laser optically sample the gated MCP. Shuttering is achieved by applying a forward biasing electrical gate pulse to the quiescently reverse-biased photocathode MCP interface. Variable delay between the gate pulse and the laser pulse permits tracing the MCP's optical response. Gating speeds, turn-on and turn-off patterns, the asymmetric spatial depedence of the MCP optical response, and resolution effects as functions of gate pulse width and photocathode-MCP bias were characterized. Variations in the intensity profiles of the phosphor's spatial response for uniform photocathode illumination are measured with a calibrated silicon intensified target focus projection, scan television camera and a high speed video digitizer while photomultipliers monitor the laser pulse and the phosphor's spatially integrated output intensities.

  12. A New Omni-Directional EMAT for Ultrasonic Lamb Wave Tomography Imaging of Metallic Plate Defects

    PubMed Central

    Huang, Songling; Wei, Zheng; Zhao, Wei; Wang, Shen

    2014-01-01

    This paper proposes a new omni-directional electromagnetic acoustic transducer (EMAT) for the ultrasonic Lamb wave (ULW) tomography imaging (TI) of defects in metallic plates. The proposed EMAT is composed of a permanent magnet and a coil with a contra-flexure structure. This new EMAT coil structure is used for omni-directional ULW transmission and reception and ULW TI for the first time. The theoretical background and the working principles of this EMAT are presented and analyzed. The experimental results of its use on a 3 mm thick aluminum plate indicate that the EMAT with a contra-flexure coil (CFC) can transmit and receive a pure single A0 mode ULW with a high signal-to-noise ratio (SNR). Thus, the extraction of the projection data used for ULW TI may be performed accurately. The circumferential consistency of the projection data is only slightly influenced by the distortion of the eddy current field that is induced by the new CFC with an irregular shape. When the new EMAT array is used for ULW TI using the cross-hole method and SIRT arithmetic, a desirable imaging quality can be achieved, and the estimated size of an artificial corrosion defect agreed well with its actual value. The relation between the reconstruction resolution and the number of the new EMATs used is analyzed. More TI experiments are carried out when the aluminum plate defect is in two different locations relative to the EMAT array, for the further investigation of the performances of the new EMATs. PMID:24561398

  13. Partially light-controlled imager based on liquid crystal plate and image intensifier for aurora and airglow measurement.

    PubMed

    Tang, Yuanhe; Cao, Xiangang; Liu, Hanchen; Shepherd, G G; Liu, Shulin; Gao, Haiyang; Yang, Xusan; Wu, Yong; Wang, Shuiwei

    2012-04-20

    In order to obtain information both of aurora and airglow in one image by the same detector, a PLCI based on liquid crystal plate LCP and super second-generation image intensifier SSGII is proposed in this research. The detection thresholds of the CCD for aurora and airglow are calculated. For the detectable illumination range of 10(4)-10(-2) lx, the corresponding electron count is 1.57×10(5) - 0.2 for every pixel of CCD. The structure and work principle of the PLCI are described. An LC is introduced in the front of CCD to decrease the intensities of aurora in overexposure areas by means of controlling transmittances pixel by pixel, while an image intensifier is set between the LC and CCD to increase the intensity of the weak airglow. The modulation transfer function MTF of this system is calculated as 0.391 at a Nyquist frequency of 15 lp/mm. The curve of transmittance with regard to gray level for the LC is obtained by calibration experiment. Based on the design principle, the prototype is made and used to take photos of objects under strong light greater than 2×10(5) lx. The clear details of [symbols: see text] presented in the image indicate that the PLCI can greatly improve the imaging quality. The theoretical calculations and experiment results prove that this device can extend the dynamic range and it provides a more effective method for upper atmospheric wind measurement.

  14. A Curved Image-Plate Detector System for High-Resolution Synchrotron X-ray Diffraction

    SciTech Connect

    Sarin, P.; Haggerty, R; Yoon, W; Knapp, M; Berghaeuser, A; Zschack, P; Karapetrova, E; Yang, N; Kriven, W

    2009-01-01

    The developed curved image plate (CIP) is a one-dimensional detector which simultaneously records high-resolution X-ray diffraction (XRD) patterns over a 38.7 2{theta} range. In addition, an on-site reader enables rapid extraction, transfer and storage of X-ray intensity information in {le}30 s, and further qualifies this detector to study kinetic processes in materials science. The CIP detector can detect and store X-ray intensity information linearly proportional to the incident photon flux over a dynamical range of about five orders of magnitude. The linearity and uniformity of the CIP detector response is not compromised in the unsaturated regions of the image plate, regardless of saturation in another region. The speed of XRD data acquisition together with excellent resolution afforded by the CIP detector is unique and opens up wide possibilities in materials research accessible through X-ray diffraction. This article presents details of the basic features, operation and performance of the CIP detector along with some examples of applications, including high-temperature XRD.

  15. Unraveling the geometry of the Farallon plate: Synthesis of three-dimensional imaging results from USArray

    NASA Astrophysics Data System (ADS)

    Pavlis, Gary L.; Sigloch, Karin; Burdick, Scott; Fouch, Matthew J.; Vernon, Frank L.

    2012-04-01

    We compare 12 recent three-dimensional (3D) seismic imaging results that made extensive use of data from the Earthscope Transportable Array (TA). Our goal is to sort out what can be said about the geometry of the Farallon plate. Our main approach is 3D visualization using a kinematic plate motion model as a framework. Comparison of results from all 12 image volumes indicates that the results are most consistent with a single, coherent Farallon slab overridden by North American. The Farallon can be tracked from the trench in the Pacific Northwest to its remnants in the lower mantle under eastern North America. From the trench the lithosphere has a low dip to the volcanic arc. Immediately east of the arc the slab steepens sharply before undergoing a decrease in dip above the 410 km discontinuity. The gently dipping section varies along strike. Under Washington the deflection is minor but to the south the slab flattens to become nearly horizontal beneath southern Idaho. There is a strong agreement that the high velocity anomaly associated with the slab vanishes under eastern Oregon. Scattered wave imaging results, however, suggest the top of the anomaly is continuous. These can be reconciled if one assumes the wavespeed anomaly has been neutralized by processes linked to the Yellowstone system. We find that all results are consistent with a 4D kinematic model of the Mendocino slab window under Nevada and Utah. In the eastern US the larger scale models all show a lower mantle anomaly related to the older history of Farallon subduction. The link between the lower mantle and new results in the U.S. Cordillera lies under the High Plains where the required USArray coverage is not yet complete. Image volumes in a unified format are supplied in an electronic supplement.

  16. Comparing Magnetic Resonance Imaging and High-Resolution Dynamic Ultrasonography for Diagnosis of Plantar Plate Pathology: A Case Series.

    PubMed

    Donegan, Ryan J; Stauffer, Anthony; Heaslet, Michael; Poliskie, Michael

    Plantar plate pathology has gained noticeable attention in recent years as an etiology of lesser metatarsophalangeal joint pain. The heightened clinical awareness has led to the need for more effective diagnostic imaging accuracy. Numerous reports have established the accuracy of both magnetic resonance imaging and ultrasonography for the diagnosis of plantar plate pathology. However, no conclusions have been made regarding which is the superior imaging modality. The present study reports a case series directly comparing high-resolution dynamic ultrasonography and magnetic resonance imaging. A multicenter retrospective comparison of magnetic resonance imaging versus high-resolution dynamic ultrasonography to evaluate plantar plate pathology with surgical confirmation was conducted. The sensitivity, specificity, and positive and negative predictive values for magnetic resonance imaging were 60%, 100%, 100%, and 33%, respectively. The overall diagnostic accuracy compared with the intraoperative findings was 66%. The sensitivity, specificity, and positive and negative predictive values for high-resolution dynamic ultrasound imaging were 100%, 100%, 100%, and 100%, respectively. The overall diagnostic accuracy compared with the intraoperative findings was 100%. The p value using Fisher's exact test for magnetic resonance imaging and high-resolution dynamic ultrasonography was p = .45, a difference that was not statistically significant. High-resolution dynamic ultrasonography had greater accuracy than magnetic resonance imaging in diagnosing lesser metatarsophalangeal joint plantar plate pathology, although the difference was not statistically significant. The present case series suggests that high-resolution dynamic ultrasonography can be considered an equally accurate imaging modality for plantar plate pathology at a potential cost savings compared with magnetic resonance imaging. Therefore, high-resolution dynamic ultrasonography warrants further investigation in

  17. Local plate/rod descriptors of 3D trabecular bone micro-CT images from medial axis topologic analysis

    SciTech Connect

    Peyrin, Francoise; Attali, Dominique; Chappard, Christine; Benhamou, Claude Laurent

    2010-08-15

    Purpose: Trabecular bone microarchitecture is made of a complex network of plate and rod structures evolving with age and disease. The purpose of this article is to propose a new 3D local analysis method for the quantitative assessment of parameters related to the geometry of trabecular bone microarchitecture. Methods: The method is based on the topologic classification of the medial axis of the 3D image into branches, rods, and plates. Thanks to the reversibility of the medial axis, the classification is next extended to the whole 3D image. Finally, the percentages of rods and plates as well as their mean thicknesses are calculated. The method was applied both to simulated test images and 3D micro-CT images of human trabecular bone. Results: The classification of simulated phantoms made of plates and rods shows that the maximum error in the quantitative percentages of plate and rods is less than 6% and smaller than with the structure model index (SMI). Micro-CT images of human femoral bone taken in osteoporosis and early or advanced osteoarthritis were analyzed. Despite the large physiological variability, the present method avoids the underestimation of rods observed with other local methods. The relative percentages of rods and plates were not significantly different between osteoarthritis and osteoporotic groups, whereas their absolute percentages were in relation to an increase of rod and plate thicknesses in advanced osteoarthritis with also higher relative and absolute number of nodes. Conclusions: The proposed method is model-independent, robust to surface irregularities, and enables geometrical characterization of not only skeletal structures but entire 3D images. Its application provided more accurate results than the standard SMI on simple simulated phantoms, but the discrepancy observed on the advanced osteoarthritis group raises questions that will require further investigations. The systematic use of such a local method in the characterization of

  18. Estimation of plate material properties by means of a complex wavenumber fit using Hankel's functions and the image source method

    NASA Astrophysics Data System (ADS)

    Roozen, N. B.; Leclère, Q.; Ege, K.; Gerges, Y.

    2017-03-01

    This paper presents a new wave fitting approach to estimate the frequency dependent material properties of thin isotropic plate structures from an experimentally obtained vibrational field, exciting the plate at a single point. The method projects the measurement data on to an analytical image source model, in which Hankel's functions are used for a description of the wave fields emanating from the point of excitation, including the reflected wave fields from the edges of the finite plate. By minimizing the error between the projected field and the measured field, varying the complex wave number and the source strengths of the image sources, an optimum fit is searched for. Thus the source strengths of the image sources do not need to be determined theoretically, but are estimated from the fit on to the experimental data instead (thus avoiding difficulties in theoretically assessing the reflection coefficient of the edges of the plate). The approach uses a complex wavenumber fit, enabling the determination of the dynamic stiffness of the plate structure and its damping properties as function of frequency. The method is especially suited for plates with a sufficient amount of damping, excited at high frequencies.

  19. Ultra-compact imaging plate scanner module using a MEMS mirror and specially designed MPPC

    NASA Astrophysics Data System (ADS)

    Miyamoto, Yuichi; Sasaki, Kensuke; Takasaka, Masaomi; Fujimoto, Masatoshi; Yamamoto, Koei

    2017-02-01

    Computed radiography (CR), which is one of the most useful methods for dental imaging and nondestructive testing, uses a phosphor imaging plate (IP) because it is flexible, reusable, and inexpensive. Conventional IP scanners utilize a galvanometer or a polygon mirror as a scanning device and a photomultiplier as an optical sensor. Microelectromechanical systems (MEMS) technology currently provides silicon-based devices and has the potential to replace such discrete devices and sensors. Using these devices, we constructed an ultra-compact IP scanner. Our extremely compact plate scanner utilizes a module that is composed of a one-dimensional MEMS mirror and a long multi-pixel photon counter (MPPC) that is combined with a specially designed wavelength filter and a rod lens. The MEMS mirror, which is a non-resonant electromagnetic type, is 2.6 mm in diameter with a recommended optical scanning angle up to +/-15°. The CR's wide dynamic range is maintained using a newly developed MPPC. The MPPC is a sort of silicon photomultiplier and is a high-sensitivity photon-counting device. To achieve such a wide dynamic range, we developed a long MPPC that has over 10,000 pixels. For size reduction and high optical efficiency, we set the MPPC close to an IP across the rod lens. To prevent the MPPC from detecting excitation light, which is much more intense than photo-stimulated light, we produced a sharp-cut wavelength filter that has a wide angle (+/-60°) of tolerance. We evaluated our constructed scanner module through gray chart and resolution chart images.

  20. Mesozoic plate-motion history below the northeast Pacific Ocean from seismic images of the subducted Farallon slab

    PubMed

    Bunge; Grand

    2000-05-18

    The high-resolution seismic imaging of subducted oceanic slabs has become a powerful tool for reconstructing palaeogeography. The images can now be interpreted quantitatively by comparison with models of the general circulation of the Earth's mantle. Here we use a three-dimensional spherical computer model of mantle convection to show that seismic images of the subducted Farallon plate provide strong evidence for a Mesozoic period of low-angle subduction under North America. Such a period of low-angle subduction has been invoked independently to explain Rocky Mountain uplift far inland from the plate boundary during the Laramide orogeny. The computer simulations also allow us to locate the largely unknown Kula-Farallon spreading plate boundary, the location of which is important for inferring the trajectories of 'suspect' terrain across the Pacific basin.

  1. Absolute Calibration of Image Plate for electrons at energy between 100 keV and 4 MeV

    SciTech Connect

    Chen, H; Back, N L; Eder, D C; Ping, Y; Song, P M; Throop, A

    2007-12-10

    The authors measured the absolute response of image plate (Fuji BAS SR2040) for electrons at energies between 100 keV to 4 MeV using an electron spectrometer. The electron source was produced from a short pulse laser irradiated on the solid density targets. This paper presents the calibration results of image plate Photon Stimulated Luminescence PSL per electrons at this energy range. The Monte Carlo radiation transport code MCNPX results are also presented for three representative incident angles onto the image plates and corresponding electron energies depositions at these angles. These provide a complete set of tools that allows extraction of the absolute calibration to other spectrometer setting at this electron energy range.

  2. Multi-mode conversion imaging of the subducted Gorda and Juan de Fuca plates below the North American continent

    NASA Astrophysics Data System (ADS)

    Tauzin, Benoit; Bodin, Thomas; Debayle, Eric; Perrillat, Jean-Philippe; Reynard, Bruno

    2016-04-01

    Receiver function analysis and seismic tomography show tectonic structures dipping eastward in the mantle below the Cascadia volcanic arc (western US) that have been related to the subduction of the Gorda and Juan de Fuca oceanic micro-plates. Inconsistencies in the dip angle and depth extent of the slab between the two methods undermine the interpretation of the structure and processes at work. Receiver function imaging is biased by multiple reflection phases that interfere with converted phases, and produce spurious discontinuities in images. Here, we correct the interference using a multiple mode conversion imaging technique that efficiently removes artifacts under dipping structures. The method has the advantage of being applicable to large aperture arrays, and can image large-scale structures down to the transition zone. With this approach, the interfaces between the subducting and overriding plates and the oceanic Moho are imaged at shallow depths (<120 km) with a dip angle of ∼20°, consistently with former studies. In addition, several important features are imaged with the present method. Faint converters located between 100 and 400 km depth in the mantle wedge, and strong sub-horizontal seismic scatterers near 160 km depth, may highlight dehydration and metasomatism processes in the Cascadia subduction zone. A discontinuity located at ∼15 km depth in the lithospheric mantle of the subducted plates and associated with a negative impedance contrast is interpreted as the fossil fabric of the plates acquired at the spreading ridges.

  3. 2-D Precise Radiation Mapping of Sedimentary Core Using Imaging Plate

    NASA Astrophysics Data System (ADS)

    Sugihara, M.; Tsuchiya, N.

    2006-12-01

    The imaging plate (IP) is a storage film coated with photostimulated phosphor (BaFBr: Eu2+), and the latent images produced by irradiation of the imaging plate are read by superficial scanning with stimulation light and are reconstructed as two-dimensional dot images on a computer display. It has an excellent performance for radiation detection, and its advantages include an ease of use, a high position resolution (up to 25ƒÊm), a large detection area (up to 35'43cm2), a high detection sensitivity with high signal-to- noise ratio, an extremely wide dynamic range of dose, a sensitivity to several kinds of radiation, and an erasing capability for reuse (Hareyama et al., 2000). In this study, in order to develop a nondestructive, precise and large area evaluation method of sedimentary structure, an application of autoradiography using IP is attempted to marine sediments. Imaging plate (BAS-MS2040 Fujifilm Co. Ltd., 20'~40 cm2) was cut into rectangular five pieces (4'~40 cm2). Whole round marine sedimentary cores were divided into two half for duplicate and they were covered with a plastic wrap. The rectangular IP were put along the center line of plane side of half round. The exposure in the low temperature was for 48 hours in a shield box. The latent images produced by irradiation of the IP were read out by using the BAS-2500 imaging analyzer (Fujifilm Co. Ltd.). Radiation dose of IP is output as PSL value, that is unique dose units and quantities of IP system. Position resolution was set to 50ƒÊm. Marine sedimentary cores including volcanic ash layer were measured using IP and Natural Gamma Logger (NGL), which is measuring instrument for marine sediments in practice use, to compare their measuring ability. As a result of experiment, it becomes clear that high dose distribution is found at volcanic ash layer with IP, meanwhile it can't be found with NGL. The content of radiation source in volcanic ash layer is supposed to be high compared with other layers

  4. Surface enhanced Raman scattering imaging of developed thin-layer chromatography plates.

    PubMed

    Freye, Chris E; Crane, Nichole A; Kirchner, Teresa B; Sepaniak, Michael J

    2013-04-16

    A method for hyphenating surface enhanced Raman scattering (SERS) and thin-layer chromatography (TLC) is presented that employs silver-polymer nanocomposites as an interface. Through the process of conformal blotting, analytes are transferred from TLC plates to nanocomposite films before being imaged via SERS. A procedure leading to maximum blotting efficiency was established by investigating various parameters such as time, pressure, and type and amount of blotting solvent. Additionally, limits of detection were established for test analytes malachite green isothiocyanate, 4-aminothiophenol, and Rhodamine 6G (Rh6G) ranging from 10(-7) to 10(-6) M. Band broadening due to blotting was minimal (∼10%) as examined by comparing the spatial extent of TLC-spotted Rh6G via fluorescence and then the SERS-based spot size on the nanocomposite after the blotting process. Finally, a separation of the test analytes was carried out on a TLC plate followed by blotting and the acquisition of distance × wavenumber × intensity three-dimensional TLC-SERS plots.

  5. Adaptive beamforming for array imaging of plate structures using lamb waves.

    PubMed

    Engholm, Marcus; Stepinski, Tadeusz

    2010-12-01

    Lamb waves are considered a promising tool for the monitoring of plate structures. Large areas of plate structures can be monitored using active arrays employing beamforming techniques. Dispersion and multiple propagating modes are issues that need to be addressed when working with Lamb waves. Previous work has mainly focused on standard delay-and-sum (DAS) beamforming while reducing the effects of multiple modes through frequency selectivity and transducer design. This paper presents a minimum variance distortionless response (MVDR) approach for Lamb waves using a uniform rectangular array (URA) and a single transmitter. Theoretically calculated dispersion curves are used to compensate for dispersion. The combination of the MVDR approach and the two-dimensional array improves the suppression of interfering Lamb modes. The proposed approach is evaluated on simulated and experimental data and compared with the standard DAS beamformer. It is shown that the MVDR algorithm performs better in terms of higher resolution and better side lobe and mode suppression capabilities. Known issues of the MVDR approach, such as signal cancellation in highly correlated environments and poor robustness, are addressed using methods that have proven effective for the purpose in other fields of active imaging.

  6. Calibration of BAS-TR image plate response to high energy (3-300 MeV) carbon ions

    NASA Astrophysics Data System (ADS)

    Doria, D.; Kar, S.; Ahmed, H.; Alejo, A.; Fernandez, J.; Cerchez, M.; Gray, R. J.; Hanton, F.; MacLellan, D. A.; McKenna, P.; Najmudin, Z.; Neely, D.; Romagnani, L.; Ruiz, J. A.; Sarri, G.; Scullion, C.; Streeter, M.; Swantusch, M.; Willi, O.; Zepf, M.; Borghesi, M.

    2015-12-01

    The paper presents the calibration of Fuji BAS-TR image plate (IP) response to high energy carbon ions of different charge states by employing an intense laser-driven ion source, which allowed access to carbon energies up to 270 MeV. The calibration method consists of employing a Thomson parabola spectrometer to separate and spectrally resolve different ion species, and a slotted CR-39 solid state detector overlayed onto an image plate for an absolute calibration of the IP signal. An empirical response function was obtained which can be reasonably extrapolated to higher ion energies. The experimental data also show that the IP response is independent of ion charge states.

  7. Study on detecting spatial distribution of neutrons and gamma rays using a multi-imaging plate system.

    PubMed

    Tanaka, Kenichi; Sakurai, Yoshinori; Endo, Satoru; Takada, Jun

    2014-06-01

    In order to measure the spatial distributions of neutrons and gamma rays separately using the imaging plate, the requirement for the converter to enhance specific component was investigated with the PHITS code. Consequently, enhancing fast neutrons using recoil protons from epoxy resin was not effective due to high sensitivity of the imaging plate to gamma rays. However, the converter of epoxy resin doped with (10)B was found to have potential for thermal and epithermal neutrons, and graphite for gamma rays. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Photon-counting detector arrays based on microchannel array plates. [for image enhancement

    NASA Technical Reports Server (NTRS)

    Timothy, J. G.

    1975-01-01

    The recent development of the channel electron multiplier (CEM) and its miniaturization into the microchannel array plate (MCP) offers the possibility of fully combining the advantages of the photographic and photoelectric detection systems. The MCP has an image-intensifying capability and the potential of being developed to yield signal outputs superior to those of conventional photomultipliers. In particular, the MCP has a photon-counting capability with a negligible dark-count rate. Furthermore, the MCP can operate stably and efficiently at extreme-ultraviolet and soft X-ray wavelengths in a windowless configuration or can be integrated with a photo-cathode in a sealed tube for use at ultraviolet and visible wavelengths. The operation of one- and two-dimensional photon-counting detector arrays based on the MCP at extreme-ultraviolet wavelengths is described, and the design of sealed arrays for use at ultraviolet and visible wavelengths is briefly discussed.

  9. Novel type of neutron image plates based on KCl:Eu2+-LiF

    NASA Astrophysics Data System (ADS)

    Schlapp, M.; Hoelzel, M.; Gilles, R.; Ioffe, A.; Brueckel, T.; Fuess, H.; Seggern, H. Von

    2004-07-01

    Neutron image plates (NIP) provide a mean for the two-dimensional, position-sensitive detection of neutrons. They combine the advantages of a large dynamic range (up to 5 orders of magnitude), good spatial resolution (<=300μm) and large detection areas. NIPs are used at various instruments for powder or single-crystal diffraction in numerous radiation facilities. They have also found an application in neutron radiography and can be used for small-angle neutron scattering (SANS) such as at the Structure Powder DIffractometer (SPODI) at the FRM-II. In this study, the resolution of a novel type of ceramic NIPs based on KCl:Eu2+-LiF is presented and simulations on the applicability of NIPs for neutron detection at the SANS apparatus of SPODI are reported.

  10. Study of imaging plate detector sensitivity to 5-18 MeV electrons

    SciTech Connect

    Boutoux, G. Rabhi, N.; Batani, D.; Ducret, J.-E.; Binet, A.; Nègre, J.-P.; Reverdin, C.; Thfoin, I.; Jakubowska, K.

    2015-11-15

    Imaging plates (IPs) are commonly used as passive detectors in laser-plasma experiments. We calibrated at the ELSA electron beam facility (CEA DIF) the five different available types of IPs (namely, MS-SR-TR-MP-ND) to electrons from 5 to 18 MeV. In the context of diagnostic development for the PETawatt Aquitaine Laser (PETAL), we investigated the use of stacks of IP in order to increase the detection efficiency and get detection response independent from the neighboring materials such as X-ray shielding and detector supports. We also measured fading functions in the time range from a few minutes up to a few days. Finally, our results are systematically compared to GEANT4 simulations in order to provide a complete study of the IP response to electrons over the energy range relevant for PETAL experiments.

  11. Lamb-Wave-Based Tomographic Imaging Techniques for Hole-Edge Corrosion Monitoring in Plate Structures

    PubMed Central

    Wang, Dengjiang; Zhang, Weifang; Wang, Xiangyu; Sun, Bo

    2016-01-01

    This study presents a novel monitoring method for hole-edge corrosion damage in plate structures based on Lamb wave tomographic imaging techniques. An experimental procedure with a cross-hole layout using 16 piezoelectric transducers (PZTs) was designed. The A0 mode of the Lamb wave was selected, which is sensitive to thickness-loss damage. The iterative algebraic reconstruction technique (ART) method was used to locate and quantify the corrosion damage at the edge of the hole. Hydrofluoric acid with a concentration of 20% was used to corrode the specimen artificially. To estimate the effectiveness of the proposed method, the real corrosion damage was compared with the predicted corrosion damage based on the tomographic method. The results show that the Lamb-wave-based tomographic method can be used to monitor the hole-edge corrosion damage accurately. PMID:28774041

  12. Calibration of imaging plates to electrons between 40 and 180 MeV.

    PubMed

    Rabhi, N; Bohacek, K; Batani, D; Boutoux, G; Ducret, J-E; Guillaume, E; Jakubowska, K; Thaury, C; Thfoin, I

    2016-05-01

    This paper presents the response calibration of Imaging Plates (IPs) for electrons in the 40-180 MeV range using laser-accelerated electrons at Laboratoire d'Optique Appliquée (LOA), Palaiseau, France. In the calibration process, the energy spectrum and charge of electron beams are measured by an independent system composed of a magnetic spectrometer and a Lanex scintillator screen used as a calibrated reference detector. It is possible to insert IPs of different types or stacks of IPs in this spectrometer in order to detect dispersed electrons simultaneously. The response values are inferred from the signal on the IPs, due to an appropriate charge calibration of the reference detector. The effect of thin layers of tungsten in front and/or behind IPs is studied in detail. GEANT4 simulations are used in order to analyze our measurements.

  13. Comparison of discrimination methods for alpha radiation signals using imaging plates.

    PubMed

    Chen, B; Zhuo, W

    2012-11-01

    The discrimination of different radiation signals is important for quantitative measurements of naturally occurring radionulides by using the technique of imaging plates (IPs). In this study, four discrimination algorithms previously proposed for discriminating and counting the incident alpha signals were experimentally compared from the view points of linearity response, the discrimination capability of alpha signals from beta signals and the detection uncertainty. The results showed that all the methods had a good linearity response and could discriminate alpha signals from beta signals. In general, a larger region of interest (ROI) has a higher detection efficiency, but the discrimination capability of alpha signals from beta signals is worse. By taking into account both the detection efficiency and the uncertainty of detection, the algorithm using an ROI of 5 × 100 μm × 100 μm was considered to be the most appropriate method for quantitative measurements of alpha radiation.

  14. Response functions of imaging plates to photons, electrons and 4He particles.

    PubMed

    Bonnet, T; Comet, M; Denis-Petit, D; Gobet, F; Hannachi, F; Tarisien, M; Versteegen, M; Aléonard, M M

    2013-10-01

    Imaging plates from Fuji (BAS-SR, MS, and TR types) are phosphor films routinely used in ultra high intensity laser experiments. However, few data are available on the absolute IP response functions to ionizing particles. We have previously measured and modeled the IP response functions to protons. We focus here on the determination of the responses to photons, electrons, and (4)He particles. The response functions are obtained on an energy range going from a few tens of keV to a few tens of MeV and are compared to available data. The IP sensitivities to the different ionizing particles demonstrate a quenching effect depending on the particle stopping power.

  15. Enhanced soft X-ray detection efficiencies for imaging microchannel plate detectors

    NASA Astrophysics Data System (ADS)

    Fraser, G. W.; Barstow, M. A.; Whiteley, M. J.; Wells, A.

    1982-12-01

    Although the microchannel plate (MCP) electron multipliers used in X-ray astronomy facilitate X-ray imaging with high spatial resolution, their intrinsic soft X-ray detection efficiencies of 1-10 percent are much lower than the near-unity values available with competing gas proportional counters. A high photoelectric yield material may be deposited on the MCP front surface and channel walls in order to enhance X-ray sensitivity at energies below a few keV. High 0.18-1.5 keV X-ray detection efficiencies are reported for MCPs bearing CsI deposition photocathodes, by which efficiency enhancement factors of up to 15 have been obtained. These results are especially pertinent to the sensitivity of such future X-ray astronomy experiments as the Roentgensatellit (Rosat) Wide Field Camera.

  16. Design study of multi-imaging plate system for BNCT irradiation field at Kyoto university reactor.

    PubMed

    Tanaka, Kenichi; Sakurai, Yoshinori; Kajimoto, Tsuyoshi; Tanaka, Hiroki; Takata, Takushi; Endo, Satoru

    2016-09-01

    The converter configuration for a multi-imaging plate system was investigated for the application of quality assurance in the irradiation field profile for boron neutron capture therapy. This was performed by the simulation calculation using the PHITS code in the fields at the Heavy Water Neutron Irradiation Facility of Kyoto University Reactor. The converter constituents investigated were carbon for gamma rays, and polyethylene with and without LiF at varied (6)Li concentration for thermal, epithermal, and fast neutrons. Consequently, potential combinations of the converters were found for two components, gamma rays and thermal neutrons, for the standard thermal neutron mode and three components of gamma rays, epithermal neutrons, and thermal or fast neutrons, for the standard mixed or epithermal neutron modes, respectively.

  17. Dual microchannel plate module for a gated monochromatic x-ray imager

    SciTech Connect

    Oertel, J.A.; Archuleta, T.; Peterson, C.G.

    1996-06-01

    Development and testing of a dual microchannel plate (MCP) module to be used in the national Inertial Confinement Fusion (ICF) program has recently been completed. The MCP module is a key component of a new monochromatic x-ray imaging diagnostic which is designed around a 4 channel Kirkpatrick-Baez microscope and diffraction crystals which is located at University of Rochester`s Omega laser system. The MCP module has two separate MCP regions with centers spaced 53 mm apart. Each region contains a 25 mm MCP proximity focused to a P-11 phosphor coated fiberoptic faceplate. The two L/D = 40, MCPs have a 10.2 mm wide, 8 ohm stripline constructed of 500 nm Copper overcoated with 100 nm Gold. A 4 kV, 150 ps electrical pulse provides an optical gatewidth of 80 ps and spatial resolution has been measured at 20 1p/mm.

  18. Response functions of imaging plates to photons, electrons and {sup 4}He particles

    SciTech Connect

    Bonnet, T.; Denis-Petit, D.; Gobet, F.; Hannachi, F.; Tarisien, M.; Versteegen, M.; Aléonard, M. M.

    2013-10-15

    Imaging plates from Fuji (BAS-SR, MS, and TR types) are phosphor films routinely used in ultra high intensity laser experiments. However, few data are available on the absolute IP response functions to ionizing particles. We have previously measured and modeled the IP response functions to protons. We focus here on the determination of the responses to photons, electrons, and {sup 4}He particles. The response functions are obtained on an energy range going from a few tens of keV to a few tens of MeV and are compared to available data. The IP sensitivities to the different ionizing particles demonstrate a quenching effect depending on the particle stopping power.

  19. Calibration of imaging plates to electrons between 40 and 180 MeV

    SciTech Connect

    Rabhi, N. Batani, D.; Boutoux, G.; Ducret, J.-E.; Bohacek, K.; Guillaume, E.; Thaury, C.; Jakubowska, K.; Thfoin, I.

    2016-05-15

    This paper presents the response calibration of Imaging Plates (IPs) for electrons in the 40-180 MeV range using laser-accelerated electrons at Laboratoire d’Optique Appliquée (LOA), Palaiseau, France. In the calibration process, the energy spectrum and charge of electron beams are measured by an independent system composed of a magnetic spectrometer and a Lanex scintillator screen used as a calibrated reference detector. It is possible to insert IPs of different types or stacks of IPs in this spectrometer in order to detect dispersed electrons simultaneously. The response values are inferred from the signal on the IPs, due to an appropriate charge calibration of the reference detector. The effect of thin layers of tungsten in front and/or behind IPs is studied in detail. GEANT4 simulations are used in order to analyze our measurements.

  20. Development of a compact E × B microchannel plate detector for beam imaging

    NASA Astrophysics Data System (ADS)

    Wiggins, B. B.; Singh, Varinderjit; Vadas, J.; Huston, J.; Steinbach, T. K.; Hudan, S.; deSouza, R. T.

    2017-09-01

    A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E × B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in one-dimension. To assess the spatial resolution, the detector was illuminated by an α-source with an intervening mask that consists of a series of precisely-machined slits. The measured spatial resolution was 520 μm FWHM, which was improved to 413 μm FWHM by performing an FFT of the signals, rejecting spurious signals on the delay line, and requiring a minimum signal amplitude. This measured spatial resolution of 413 μm FWHM corresponds to an intrinsic resolution of 334 μm FWHM when the effect of the finite slit width is de-convoluted. To understand the measured resolution, the performance of the detector is simulated with the ion-trajectory code SIMION.

  1. Microchannel plates and image detection at soft X-ray wavelengths

    NASA Technical Reports Server (NTRS)

    Timothy, J. G.

    1986-01-01

    Detector systems based on the high-gain microchannel plate (MCP) electron multiplier have been used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse-counting electronic readout systems provide zero readout-noise, spatial resolutions (FWM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can br developed to produce detectors with active areas of 100 mm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies to wavelengths between about 100 and 1A (0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described, and the prospects for future developments are discussed.

  2. Development of a compact E?B microchannel plate detector for beam imaging

    DOE PAGES

    Wiggins, B. B.; Singh, Varinderjit; Vadas, J.; ...

    2017-06-17

    A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E×B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in one-dimension. To assess the spatial resolution, the detector was illuminated by an α-source with an intervening mask that consists of a series of precisely-machined slits. The measured spatial resolution was 520 um source FWHM, which was improved to 413 um FWHM by performing an FFT of the signals, rejecting spurious signals on the delay line, and requiring a minimum signal amplitude. This measured spatialmore » resolution of 413 um FWHM corresponds to an intrinsic resolution of 334 um FWHM when the effect of the finite slit width is de-convoluted. To understand the measured resolution, the performance of the detector is simulated with the ion-trajectory code SIMION.« less

  3. Hierarchical and successive approximate registration of the non-rigid medical image based on thin-plate splines

    NASA Astrophysics Data System (ADS)

    Hu, Jinyan; Li, Li; Yang, Yunfeng

    2017-06-01

    The hierarchical and successive approximate registration method of non-rigid medical image based on the thin-plate splines is proposed in the paper. There are two major novelties in the proposed method. First, the hierarchical registration based on Wavelet transform is used. The approximate image of Wavelet transform is selected as the registered object. Second, the successive approximation registration method is used to accomplish the non-rigid medical images registration, i.e. the local regions of the couple images are registered roughly based on the thin-plate splines, then, the current rough registration result is selected as the object to be registered in the following registration procedure. Experiments show that the proposed method is effective in the registration process of the non-rigid medical images.

  4. High Spatial Resolution Investigations of Microchannel Plate Imaging Properties for UV Detectors

    NASA Technical Reports Server (NTRS)

    Siegmund, Oswald

    1996-01-01

    Microchannel plate (MCP) photon counting detectors are currently being used with great success on many of the recent NASA/ESA ultraviolet (UV) astrophysics missions that make observations in the 1OO A - 1600 A range. These include HUT, the Wide Field Camera on ROSAT, EUVE, ALEXIS, ORFEUS, and SOHO. These devices have also been chosen to fly on future UV astrophysics missions such as FUSE, FUVITA, IMAGE, and both the HST STIS and Advanced Camera instruments. During the period of this award we have fabricated a dual-chamber vacuum test facility to carry out laboratory testing of detector resolution, image stability and linearity, and flat field performance to enable us to characterize the performance of MCPs and their associated read-out architectures. We have also fabricated and tested a laboratory 'test-bed' delay line detector, which can accommodate MCP's with a wide range of formats and run at high data rates, to continue our studies of MCP image fixed pattern noise, and particularly for new small pore MCP's which have recently come onto the market. These tests were mainly focussed on the assessment of cross delay-line (XDL) and double delay line (DDL) anode read-out schemes, with particular attention being focussed on flat-field and spatial resolution performance.

  5. Imaging of Lamb Waves in Plates for Quantitative Determination of Anisotropy using Photorefractive Dynamic Holography

    SciTech Connect

    Telschow, Kenneth Louis; Deason, Vance Albert; Schley, Robert Scott; Watson, Scott Marshall

    1998-06-01

    Anisotropic properties of sheet materials can be determined by measuring the propagation of Lamb waves in different directions. Electromagnetic acoustic transduction and laser ultrasonic methods provide noncontacting approaches that are often desired for application to industrial and processing environments. This paper describes a laser imaging approach utilizing the adaptive property of photorefractive materials to produce a real-time measurement of the antisymmetric Lamb wave mode in all directions simultaneously. Continuous excitation is employed enabling the data to be recorded and displayed by a CCD camera. Analysis of the image produces a direct quantitative determination of the phase velocity in all directions showing plate anisotropy in the plane. Many optical techniques for measuring ultrasonic motion at surfaces have been developed for use in applications such as vibration measurement and laser ultrasonics. Most of these methods have similar sensitivities and are based on time domain processing using homodyne, Fabry-Perot [1], and, more recently, photorefractive interferometry [2]. Generally, the methods described above do not allow measurement at more than one surface point simultaneously, requiring multiple beam movements and scanning in order to produce images of surface ultrasonic motion over a large area. Electronic speckle interferometry, including shearography, does provide images directly of vibrations over large surface areas. This method has proven very durable in the field for large displacement amplitudes of several wavelengths. In addition, a sensitivity of ë/3000 has been demonstrated under laboratory conditions [3]. Full-field imaging of traveling ultrasonic waves using digital shearography has been recently reported with sensitivity in the nanometer range [4]. With this method, optical interference occurs at the photodetector

  6. High-content imaging with micropatterned multiwell plates reveals influence of cell geometry and cytoskeleton on chromatin dynamics.

    PubMed

    Harkness, Ty; McNulty, Jason D; Prestil, Ryan; Seymour, Stephanie K; Klann, Tyler; Murrell, Michael; Ashton, Randolph S; Saha, Krishanu

    2015-10-01

    Understanding the mechanisms underpinning cellular responses to microenvironmental cues requires tight control not only of the complex milieu of soluble signaling factors, extracellular matrix (ECM) connections and cell-cell contacts within cell culture, but also of the biophysics of human cells. Advances in biomaterial fabrication technologies have recently facilitated detailed examination of cellular biophysics and revealed that constraints on cell geometry arising from the cellular microenvironment influence a wide variety of human cell behaviors. Here, we create an in vitro platform capable of precise and independent control of biochemical and biophysical microenvironmental cues by adapting microcontact printing technology into the format of standard six- to 96-well plates to create MicroContact Printed Well Plates (μCP Well Plates). Automated high-content imaging of human cells seeded on μCP Well Plates revealed tight, highly consistent control of single-cell geometry, cytoskeletal organization, and nuclear elongation. Detailed subcellular imaging of the actin cytoskeleton and chromatin within live human fibroblasts on μCP Well Plates was then used to describe a new relationship between cellular geometry and chromatin dynamics. In summary, the μCP Well Plate platform is an enabling high-content screening technology for human cell biology and cellular engineering efforts that seek to identify key biochemical and biophysical cues in the cellular microenvironment.

  7. Deeply trapped electrons in imaging plates and their utilization for extending the dynamic range

    NASA Astrophysics Data System (ADS)

    Ohuchi, Hiroko; Kondo, Yasuhiro

    2010-09-01

    The absorption spectra of deep centers in an imaging plate (IP) made of BaFBr 0:85I 0:15:Eu 2+ have been studied in the ultraviolet region. Electrons trapped in deep centers are considered to be the cause of unerasable and reappearing latent images in IPs over-irradiated with X-rays. Deep centers showed a dominant peak at around 320 nm, followed by two small peaks at around 345 and 380 nm. By utilizing deeply trapped electrons, we have attempted to extend the dynamic range of an IP. The IP was irradiated by 150-kV X-rays with doses from 8.07 mGy to 80.7 Gy. Reading out the latent image by the stimulation of Eu 2+ luminescence with a 633-nm He-Ne laser light from a conventional Fuji reader showed a linear relationship with irradiated dose up to 0.8 Gy, but then becoming non-linear. After fully erasing with visible light, unerasable latent images were read out using 635-nm semi-conductor laser light combined with a photon-counting detection system. The dose-response curve so obtained gave a further two orders of magnitude extending the dynamic range up to 80.7 Gy. Comprehensive results indicate that electrons supplied from deep centers to the F centers provided the extended dynamic range after the F centers became saturated. Based on these facts, a model of the excitation of deeply trapped electrons and PSL processes is proposed.

  8. Interlaced zone plate optics for hard X-ray imaging in the 10 nm range

    PubMed Central

    Mohacsi, Istvan; Vartiainen, Ismo; Rösner, Benedikt; Guizar-Sicairos, Manuel; Guzenko, Vitaliy A.; McNulty, Ian; Winarski, Robert; Holt, Martin V.; David, Christian

    2017-01-01

    Multi-keV X-ray microscopy has been particularly successful in bridging the resolution gap between optical and electron microscopy. However, resolutions below 20 nm are still considered challenging, as high throughput direct imaging methods are limited by the availability of suitable optical elements. In order to bridge this gap, we present a new type of Fresnel zone plate lenses aimed at the sub-20 and the sub-10 nm resolution range. By extending the concept of double-sided zone plate stacking, we demonstrate the doubling of the effective line density and thus the resolution and provide large aperture, singlechip optical devices with 15 and 7 nm smallest zone widths. The detailed characterization of these lenses shows excellent optical properties with focal spots down to 7.8 nm. Beyond wave front characterization, the zone plates also excel in typical imaging scenarios, verifying their resolution close to their diffraction limited optical performance.

  9. Interlaced zone plate optics for hard X-ray imaging in the 10 nm range

    NASA Astrophysics Data System (ADS)

    Mohacsi, Istvan; Vartiainen, Ismo; Rösner, Benedikt; Guizar-Sicairos, Manuel; Guzenko, Vitaliy A.; McNulty, Ian; Winarski, Robert; Holt, Martin V.; David, Christian

    2017-03-01

    Multi-keV X-ray microscopy has been particularly successful in bridging the resolution gap between optical and electron microscopy. However, resolutions below 20 nm are still considered challenging, as high throughput direct imaging methods are limited by the availability of suitable optical elements. In order to bridge this gap, we present a new type of Fresnel zone plate lenses aimed at the sub-20 and the sub-10 nm resolution range. By extending the concept of double-sided zone plate stacking, we demonstrate the doubling of the effective line density and thus the resolution and provide large aperture, singlechip optical devices with 15 and 7 nm smallest zone widths. The detailed characterization of these lenses shows excellent optical properties with focal spots down to 7.8 nm. Beyond wave front characterization, the zone plates also excel in typical imaging scenarios, verifying their resolution close to their diffraction limited optical performance.

  10. Nanosecond Gating Properties Of Proximity-Focused Microchannel-Plate Image Intensifiers

    NASA Astrophysics Data System (ADS)

    King, N. S.; Yates, G. J.; Jaramillo, S. A.; Ogle, J. W.; Detch, J. L.

    1981-12-01

    Some fundamental properties of 18-mm-diam gated proximity-focussed microchannel-plate (MCP) image intensifiers used as fast image shutters in the 1 to 10 ns range have been identified and studied. Light pulses (≍ 5-ps-wide) from a modelocked dye laser optically sample the gated MCP. Shuttering is achieved by applying a forward-biasing electrical gate pulse to the quiescently reverse-biased photocathode-MCP interface. Variable delay (≍ 30-ps jitter) between the gate pulse and the laser pulse permit tracing the MCP's optical response. Gating speeds, turn-on and turn-off patterns, the asymmetric spatial dependence of the MCP optical response, and resolution effects as functions of gate pulse width and photocathode-MCP bias have been characterized. Shutter times of >= 750 ps and <= 5 1p/mm resolution with the MCP fully on were observed. Variations in the intensity profiles of the phosphorl.s spatial response for uniform photocathode illumination are measured with a calibrated silicon-intensified-target (SIT) focus projection, scan (FPS) television camera and a high-speed video digitizer while photomultipliers (PMTs) monitor the laser pulse and the phosphor's spatially integrated output intensities. The characterization system, gating and biasing circuits, and experimental results will be presented.

  11. The extraction of accurate coordinates of images on photographic plates by means of a scanning type measuring machine

    NASA Technical Reports Server (NTRS)

    Ross, B. E.

    1971-01-01

    The Moire method experimental stress analysis is similar to a problem encountered in astrometry. It is necessary to extract accurate coordinates from images on photographic plates. The solution to the mutual problem found applicable to the field of experimental stress analysis is presented to outline the measurement problem. A discussion of the photo-reading device developed to make the measurements follows.

  12. Scanning-slit photon counting x-ray imaging system using a microchannel plate detector.

    PubMed

    Shikhaliev, Polad M; Xu, Tong; Le, Huy; Molloi, Sabee

    2004-05-01

    An experimental prototype of a novel photon counting x-ray imaging system was evaluated. This system is based on an "edge-on" microchannel plate (MCP) detector and utilizes scanning slit imaging configuration. The detector is capable of photon counting, direct conversion, high spatial resolution, controllable physical charge amplification, quantum limited and scatter free operation. The detector provides a 60 mm wide field of view (FOV) and its count rate is 200 kHz for the entire FOV. The count rate of the current system is limited by the position encoding electronics, which has a single input for all events from the entire detector, and incorporates a single channel ADC with 1 micros conversion time. It is shown that the count rate can potentially be improved to clinically acceptable levels using multichannel application specific integrated circuit (ASIC) electronics and multi-slit image acquisition geometry. For a typical acquisition time used in this study, the image noise was measured to be less than the typically acceptable noise level for medical x-ray imaging. It is anticipated that the noise level will be also low after the implementation of the ASIC electronics. The quantum efficiency of the detector was measured to be 40%-56% for an energy range of 50-90 kVp for MCPs used in this study and can be improved to > 80% using MCPs with the optimized parameters. Images of resolution and anthropomorphic phantoms were acquired at an x-ray tube voltage of 50 kVp. The value of contrast transfer function for the detector was measured to be 0.5 at a spatial frequency of 5 lp/mm. The intrinsic spatial resolution of the system is 28 microm FWHM and was limited by the accuracy of the time-to-digital conversion of the position encoding electronics. Given the advantages of the edge-on MCP detector such as direct conversion and physical charge amplification, it can potentially be applied to mammography and chest radiography.

  13. Seismic Imaging of the southern Rivera Plate and Jalisco Block Subduction Zone

    NASA Astrophysics Data System (ADS)

    Nunez, D.; Nuñez-Cornu, F. J.; Barba, D. C., Sr.; Gonzalez-Fernandez, A.; Gutierrez, Q. J.; Carrillo de la Cruz, J. L.; Danobeitia, J.; Bartolome, R.

    2016-12-01

    The importance of structural aspects and high seismic activity risk of the Jalisco Block makes the Pacific Coast of Mexico in one of the most attractive region for geophysical investigations. Furthermore, tectonic studies in this interesting geological region of the Rivera-North American contact zone, carried out during last two years by TSUJAL Project, are currently providing numerous geophysical results. In this study, we present the most relevant results in the southeastern part of the Rivera Plate-Jalisco Block area crossing the Mesoamerican Trench from to the east of Rivera Fracture Zone to La Huerta region (Jalisco state). Along this profile, we have combined wide-angle, multichannel seismic, multibeam bathymetry and seismicity data. The marine seismic sources used in this profile aboard RRS James Cook consisted of 12 guns divided in 4 subarrays of 3 guns each, with a total capacity of 5800 in3, shooting every 50 m and providing 1773 shots in a line of 89 km long. These sources were initially designed to recover multichannel seismic data, but 7 seismic portable stations were deployed perpendicular to the coast to register those sources providing a wide-angle offshore-onshore seismic transect of 130 km length with NE-SW orientation. The MCS data were also acquired aboard the RRS James Cook using a 5.85 km long digital streamer deployed at 10 m depth with 468 active channels. The WAS and MCS data processing and interpretation joined bathymetry afford new information about the geometry of southern Rivera Plate subducting under Jalisco Block with a dip angle of 14°, seismic images of the continental accretionary wedge and, also, the deep and shallow crustal structure along this profile up to maximum depth of 35 km.

  14. Ultrasound imaging for diagnosis of plantar plate ruptures of the lesser metatarsophalangeal joints: a retrospective case series.

    PubMed

    Carlson, Russell M; Dux, Katherine; Stuck, Rodney M

    2013-01-01

    Tears of the plantar plate can be a source of significant forefoot pain, leading to alterations of foot function and gait. The objective of the present retrospective study was to further determine the value of ultrasound imaging in diagnosing plantar plate tears after clinical evaluation through a comparison of the ultrasound and intraoperative examination findings. Eight patients were identified who had undergone surgical intervention for a painful lesser metatarsophalangeal joint after ultrasound examination to diagnose a plantar plate pathologic entity. The intraoperative examination findings were used to calculate the sensitivity, specificity, and positive and negative predictive values of ultrasound in the diagnosis of plantar plate tears. The sensitivity and specificity of the ultrasound examination was 1 and 0.6, respectively. The positive and negative predictive value was 0.6 and 1, respectively. An ultrasound examination in the diagnosis of lesser metatarsophalangeal joint plantar plate tears displayed comparable sensitivity in identifying the pathologic features when compared with magnetic resonance imaging, with considerably less financial cost for the examination.

  15. BOLIVAR: the Caribbean-South America plate boundary between 60W and 71W as imaged by seismic reflection data

    NASA Astrophysics Data System (ADS)

    Magnani, M.; Mann, P.; Clark, S. A.; Escalona, A.; Zelt, C. A.; Christeson, G. L.; Levander, A.

    2007-12-01

    We present the results of ~6000km of marine multi-channel seismic (MCS) reflection data collected offshore Venezuela as part of the Broadband Ocean Land Investigation of Venezuela and the Antilles arc Region project (BOLIVAR). The imaged area spans almost 12 degrees of longitude and 5 degrees of latitude and encompasses the diffuse plate boundary between South America (SA) and the SE Caribbean plate (CAR). This plate boundary has been evolving for at least the past 55My when the volcanic island arc that borders the CAR plate started colliding obliquely with the SA continent: the collision front has migrated from west to east. BOLIVAR MCS data show that the crustal architecture of the present plate boundary is dominated by the eastward motion of the Caribbean plate with respect to SA and is characterized by a complex combination of convergent and strike-slip tectonics. To the north, the reflection data image the South Caribbean Deformed Belt (SCDB) and the structures related to the thrusting of the CAR plate under the Leeward Antilles volcanic arc region. The data show that the CAR underthrusting continues as far east as the southern edge of the Aves ridge and detailed stratigraphic dating of the Venezuela basin and trench deposits suggests that the collision began in the Paleogene. The amount of shortening along the SCDB decreases toward the east, in part due to the geometry of plate motion vectors and in part as a result of the NNE escape of the Maracaibo block in western Venezuela. South of the SCDB the MCS profiles cross the Leeward Antilles island arc and Cenozoic sedimentary basins, revealing a complex history of Paleogene-Neogene multiphase extension, compression, and tectonic inversion, as well as the influence of the tectonic activity along the right-lateral El Pilar - San Sebastian fault system. East of the Bonaire basin the MCS data image the southern end of the Aves Ridge abandoned volcanic island arc and the southwestern termination of the Grenada basin

  16. Multi-Mode Electromagnetic Ultrasonic Lamb Wave Tomography Imaging for Variable-Depth Defects in Metal Plates.

    PubMed

    Huang, Songling; Zhang, Yu; Wang, Shen; Zhao, Wei

    2016-05-02

    This paper proposes a new cross-hole tomography imaging (CTI) method for variable-depth defects in metal plates based on multi-mode electromagnetic ultrasonic Lamb waves (LWs). The dispersion characteristics determine that different modes of LWs are sensitive to different thicknesses of metal plates. In this work, the sensitivities to thickness variation of A0- and S0-mode LWs are theoretically studied. The principles and procedures for the cooperation of A0- and S0-mode LW CTI are proposed. Moreover, the experimental LW imaging system on an aluminum plate with a variable-depth defect is set up, based on A0- and S0-mode EMAT (electromagnetic acoustic transducer) arrays. For comparison, the traditional single-mode LW CTI method is used in the same experimental platform. The imaging results show that the computed thickness distribution by the proposed multi-mode method more accurately reflects the actual thickness variation of the defect, while neither the S0 nor the A0 single-mode method was able to distinguish thickness variation in the defect region. Moreover, the quantification of the defect's thickness variation is more accurate with the multi-mode method. Therefore, theoretical and practical results prove that the variable-depth defect in metal plates can be successfully quantified and visualized by the proposed multi-mode electromagnetic ultrasonic LW CTI method.

  17. Multi-Mode Electromagnetic Ultrasonic Lamb Wave Tomography Imaging for Variable-Depth Defects in Metal Plates

    PubMed Central

    Huang, Songling; Zhang, Yu; Wang, Shen; Zhao, Wei

    2016-01-01

    This paper proposes a new cross-hole tomography imaging (CTI) method for variable-depth defects in metal plates based on multi-mode electromagnetic ultrasonic Lamb waves (LWs). The dispersion characteristics determine that different modes of LWs are sensitive to different thicknesses of metal plates. In this work, the sensitivities to thickness variation of A0- and S0-mode LWs are theoretically studied. The principles and procedures for the cooperation of A0- and S0-mode LW CTI are proposed. Moreover, the experimental LW imaging system on an aluminum plate with a variable-depth defect is set up, based on A0- and S0-mode EMAT (electromagnetic acoustic transducer) arrays. For comparison, the traditional single-mode LW CTI method is used in the same experimental platform. The imaging results show that the computed thickness distribution by the proposed multi-mode method more accurately reflects the actual thickness variation of the defect, while neither the S0 nor the A0 single-mode method was able to distinguish thickness variation in the defect region. Moreover, the quantification of the defect’s thickness variation is more accurate with the multi-mode method. Therefore, theoretical and practical results prove that the variable-depth defect in metal plates can be successfully quantified and visualized by the proposed multi-mode electromagnetic ultrasonic LW CTI method. PMID:27144571

  18. Automated Sampling and Imaging of Analytes Separated on Thin-Layer Chromatography Plates Using Desorption Electrospray Ionization Mass Spectrometry

    SciTech Connect

    Van Berkel, Gary J; Kertesz, Vilmos

    2006-01-01

    Modest modifications to the atmospheric sampling capillary of a commercial electrospray mass spectrometer and upgrades to an in-house developed surface positioning control software package (HandsFree TLC/MS ) were used to enable the automated sampling and imaging of analytes on and/or within large area surface substrates using desorption electrospray ionization mass spectrometry. Sampling and imaging of rhodamine dyes separated on TLC plates were used to illustrate some of the practical applications of this system. Examples are shown for user-defined spot sampling from separated bands on a TLC plate (one or multiple spots), scanning of a complete development lane (one or multiple lanes), or imaging of analyte bands in a development lane (i.e. multiple lane scans with close spacing). The post data processing and data display aspects of the software system are also discussed.

  19. 90Sr in mammal teeth from contaminated areas in the former Soviet Union measured by imaging plates.

    PubMed

    Toyoda, Shin; Hino, Yoshitsugu; Romanyukha, Alexander A; Tarasov, Oleg; Pivovarov, Sergey P; Hoshi, Masaharu

    2010-02-01

    Imaging plates sensitive to beta rays were used to obtain the images of 90Sr in tooth samples taken from mammals collected in contaminated areas of the former Soviet Union. The average concentrations of 90Sr in the samples were determined by comparing the intensities of the luminescence using a single crystal of KCl. The results showed that the determined 90Sr concentration has a positive correlation with the soil contamination levels in the South Ural region. Tooth samples from both inside of the Semipalatinsk nuclear test site and the villages nearby have detectable amounts of 90Sr, indicating the possible presence of residual soil contamination. The present study demonstrates that using imaging plates is a very sensitive method to detect 90Sr in teeth as well as to estimate low-level 90Sr contamination in soil.

  20. Determination of half value layers of X-ray equipment using computed radiography imaging plates.

    PubMed

    Ariga, Eiji; Ito, Shigeki; Deji, Shizuhiko; Saze, Takuya; Nishizawa, Kunihide

    2012-01-01

    A method for determining half value layers (HVLs) of inverter-type X-ray equipment using a computed radiography (CR) systems was developed. This method is similar to the traditional method, where the air kerma (K) is measured using an ionization based dosimeter and increasing aluminum (Al) absorber thickness, but utilized an imaging plate (IP) and the sensitivity index (S number) of the CR system as the dosimeter and the dosimeter reading, respectively. The IP and the S number were calibrated using an ionization chamber having traceability to the National Standard Ionization Chamber. A modified version of the S number definition equation K=a × S(-b) was used to translate the S number to K values for X-ray beams produced using tube voltages ranging from 50 to 120 kV and additional Al filtration up to 2.5mm. The coefficient 'a' varied depending on the beam quality, while the coefficient 'b' showed a constant value of 0.991. The HVLs in the range from 1.8 to 5.5mm Al that were obtained with this method were in good agreement with those obtained with the traditional method, as uncertainties were between -7 and 4%. This method can be used to determine the HVLs of inverter-type X-ray equipment within an acceptable accuracy. Copyright © 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  1. Cross strip microchannel plate imaging photon counters with high time resolution

    SciTech Connect

    Stonehill, Laura C; Shirey, Robert; Rabin, Michael W; Thompson, David C; Siegmund, Oswald H W; Vallerga, John V; Tremsin, Anton S

    2010-01-01

    We have implemented cross strip readout microchannel plate detectors in 18 mm active area format including open face (UV/particle) and sealed tube (optical) configurations. These have been tested with a field programmable gate array based parallel channel electronics for event encoding which can process high input event rates (> 5 MHz) with high spatial resolution. Using small pore MCPs (6 {micro}m) operated in a pair, we achieve gains of >5 x 10{sup 5} which is sufficient to provide spatial resolution of <35 {micro}m FHWM, with self triggered event timing accuracy of {approx}2 ns for sealed tube optical sensors. A peak quantum efficiency of {approx}19% at 500 nm has been achieved with SuperGenII photocathodes that have response over the 400 nm to 900 nm range. Local area counting rates of up to >200 events/mcp pore sec{sup -1} have been attained, along with image linearity and stability to better than 50 {micro}m.

  2. Pulsed X-ray Characterization of Stripline Micro-Channel Plate Gated Imager

    SciTech Connect

    F. J. Goldin, D. V. Morgan, K. J. Moy

    2011-03-30

    We report on characterization of x-ray imaging arrays developed by National Security Technologies, LLC. These devices are based on a microchannel plate (MCP) with a conventional glass microchannel structure, but the top and bottom conductive coatings, rather than covering the entire area, are configured into several (4 to 8) parallel strips. Since the bias voltage is a pulse launched from one end, these operate as striplines; relative delays between these pulses give different active exposure times. Unlike the case of a static bias voltage, non-uniformities in impedance along a stripline will produce spatial fluctuations in the bias voltage. These are expected to be slight, but the very sensitive dependence of gain on voltage - approximately like Vl/4d, where l and d are the length and diameter of the channel - means there may be very significant spatial non-uniformities in gain. Flat-field calibrations are therefore required so that such effects can be unfolded from the raw images if quantitative data is required. Such flat-field and other characterization measurements, e.g. responsivity and linearity, have therefore been done with a flash X-ray radiographic system. The maximum endpoint energy is 500 keV. The duration is {approx}40 ns, and so is essentially flat (temporally) during the MCP stripline transit time, which is a maximum of 600 ps. Spatial variations are significant, but the data are corrected using independent flat-field measurements. A monochromator selects a particular X-ray transition line (typically K{alpha}) of the anode material, so that characterizations can be done for various well-defined input photon energies.

  3. High-resolution Imaging of the Philippine Sea Plate subducting beneath Central Japan

    NASA Astrophysics Data System (ADS)

    Padhy, S.; Furumura, T.

    2016-12-01

    Thermal models predict that the oceanic crust of the young (<20 Ma) and warmer Philippine-sea plate (PHP) is more prone to melting. Deriving a high-resolution image of the PHP, including slab melting and other features of the subduction zone, is a key to understand the basics of earthquake occurrence and origin of magma in complex subduction zone like central Japan, where both the PHP and Pacific (PAC) Plates subduct. To this purpose, we analyzed high-resolution waveforms of moderate sized (M 4-6), intermediate-to-deep (>150 km) PAC earthquakes occurring in central Japan and conducted numerical simulation to derive a fine-scale PHP model, which is not constrained in earlier studies. Observations show spindle-shaped seismograms with strong converted phases and extended coda with very slow decay from a group of PAC events occurring in northern part of central Japan and recorded by high-sensitivity seismograph network (Hi-net) stations in the region. We investigate the mechanism of propagation of these anomalous waveforms using the finite difference method (FDM) simulation of wave propagation through the subduction zone. We examine the effects on waveform changes of major subduction zone features, such as the melting of oceanic crust in PHP, serpentinized mantle wedge, hydrated layer on the PAC due to slab dehydration, and anomaly in upper mantle between the PAC and PHP. Simulation results show that the waveform anomaly is primarily explained by strong scattering and absorption of high-frequency energy by the low-velocity anomalous mantle structure, with a strong coda excitation yielding spindle-shaped waveforms. The data are secondarily explained by melting of PHP in the basaltic crust. The location of the mantle anomaly is tightly constrained by the observation and evidence of PAC thinning in the region; these localized low-velocity structures aid in ascending the slab-derived fluids around the slab thinning. We expect that the results of this study will enhance our

  4. Imaging of Lesser Metatarsophalangeal Joint Plantar Plate Degeneration, Tear, and Repair.

    PubMed

    Linklater, James M; Bird, Stephen J

    2016-04-01

    Plantar plate degeneration and tear is a common cause of forefoot pain, typically involving the second metatarsophalangeal joint at the proximal phalangeal insertion laterally, frequently confused with the second web space Morton neuroma. The condition has received increased attention with the development of surgical techniques that can result in successful repair of the plantar plate and substantial improvement in patient symptoms. High-resolution MRI or ultrasound can confirm a diagnosis of plantar plate degeneration and tear and exclude other pathologies, particularly Morton neuroma. The normal plantar plate is a mildly hyperechoic structure on ultrasound and is hypointense on all conventional MR sequences. Plantar plate degeneration manifests on ultrasound as hypoechoic echotextural change and on MRI as mild signal hyperintensity on short TE sequences, becoming less conspicuous on long TE sequences. Adjacent entheseal bony irregularity is commonly present. Plantar plate tears on ultrasound may be seen as an anechoic cleft defect or area of heterogeneous echotexture, sometimes more conspicuous with dorsiflexion stress. Plantar plate tears demonstrate greater signal hyperintensity on proton-density sequences, becoming more conspicuous on fat-suppressed proton density and T2-weighted sequences. Edema and fibrotic change in the pericapsular fat plane is commonly seen in the setting of an adjacent plantar plate tear and should not be misinterpreted as reflecting a Morton neuroma.

  5. Development of hyperspectral imaging technique for salmonella enteritidis and typhimurium on agar plates

    USDA-ARS?s Scientific Manuscript database

    Salmonella is a common cause of foodborne disease resulting from the consumption of contaminated food products. Although a direct plating method is widely used for presumptive positive screening of pathogenic Salmonella colonies on agar plates, it is labor-intensive, time-consuming and also prone to...

  6. Quantitative Evaluation of Growth Plates around the Knees of Adolescent Soccer Players by Diffusion-Weighted Magnetic Resonance Imaging

    PubMed Central

    Krajnc, Zmago; Rupreht, Mitja; Drobnič, Matej

    2015-01-01

    Purpose. To quantitatively evaluate growth plates around the knees in adolescent soccer players utilizing the diffusion-weighted MR imaging (DWI). Methods. The knees and adjacent growth plates of eleven 14-year-old male soccer players were evaluated by MRI before (end of season's summer break) and after two months of intense soccer training. MRI evaluation was conducted in coronal plane by PD-FSE and DWI. All images were screened for any major pathological changes. Later, central growth plate surface area (CGPSA) was measured and the apparent diffusion coefficient (ADC) values were calculated in two most central coronal slices divided into four regions: distal femur medial (DFM), distal femur lateral (DFL), proximal tibia medial (PTM), and proximal tibia lateral (PTL). Results. No gross pathology was diagnosed on MRI. CGPSA was not significantly reduced: DFM 278 versus 272, DFL 265 versus 261, PTM 193 versus 192, and PTL 214 versus 210. ADC decrease was statistically significant only for PTM: DFM 1.27 versus 1.22, DFL 1.37 versus 1.34, PTM 1.13 versus 1.03 (p = 0.003), and PTL 1.28 versus 1.22. Conclusions. DWI measurements indicate increased cellularity in growth plates around knees in footballers most prominent in PTM after intense training. No detectable differences on a standard PD-FSE sequence were observed. PMID:26693482

  7. Segmented Subduction Across the Juan De Fuca Plate: Challenges in Imaging with an Amphibious Array

    NASA Astrophysics Data System (ADS)

    Hawley, W. B.; Allen, R. M.

    2014-12-01

    The Cascadia Initiative (CI) is an amphibious array spanning the Juan de Fuca plate from formation at the ridge to the destruction of the slab in the mantle beneath western North America. This ambitions project has occupied over 300 onshore and offshore sites, providing an unprecedented opportunity to understand the dynamics of oceanic plates. The CI project is now in its fourth and final year of deployment. Here we present constraints on the structure of the Juan de Fuca plate and its interaction with western North America. We identify segmentation along the Cascadia subduction zone that can be traced back onto the Juan de Fuca plate prior to subduction. These results give insight into the life cycle of oceanic plates, from their creation at a mid-ocean ridge to their subduction and subsequent recycling into the mantle.

  8. Characterization Studies and Performance of Half-strip High-speed X-ray Microchannel Plate Imager

    SciTech Connect

    Kenneth Moy; Ming Wu

    2008-03-01

    High-speed microchannel plate (MCP)–based imagers are critical detectors for x-ray diagnostics employed on Z-experiments at Sandia National Laboratories (SNL) to measure time-resolved x-ray spectra and to image dynamic hohlraums. A design using eight half-strip x-ray photocathodes in one imager permits recordings of radiation events in discrete temporal snapshots to yield a time-evolved movie. We present data using various facilities to characterize the performance of this design. These characterization studies include DC and pulsed-voltage biased measurements in both saturated and linear operational regimes using an intense, short-pulsed UV laser and Manson source. Surface voltage profile measurements using a picoprobe help to determine the gain variation across the strips. Test data from a recent SNL ZR-experiment demonstrates the flexibility and high-quality images obtained by this MCP imager.

  9. Optical and UV Sensing Sealed Tube Microchannel Plate Imaging Detectors with High Time Resolution

    NASA Astrophysics Data System (ADS)

    Siegmund, O.; Vallerga, J.; Tremsin, A.; Hull, J.; Elam, J.; Mane, A.

    2014-09-01

    Microchannel plate (MCP) based imaging, photon time tagging detector sealed tube schemes have a unique set of operational features that enable high time resolution astronomical and remote sensing applications to be addressed. New detectors using the cross strip (XS), cross delay line (XDL), or stripline anode readouts, a wide range of photocathode types, and advanced MCP technologies have been implemented to improve many performance characteristics. A variety of sealed tubes have been developed including 18mm XS readout devices with GaAs and SuperGenII photocathodes, 25mm XDL readout devices with SuperGenII and GaN photocathodes, and 20 x 20 cm sealed tubes with bialkali photocathodes and strip line readout. One key technology that has just become viable is the ability to make MCPs using atomic layer deposition (ALD) techniques. This employs nanofabrication of the active layers of an MCP on a microcapillary array. This technique opens new performance opportunities, including, very large MCP areas (>20cm), very low intrinsic background, lower radiation induced background, much longer overall lifetime and gain stability, and markedly lower outgassing which can improve the sealed tube lifetime and ease of fabrication. The XS readout has been implemented in formats of 22mm, 50mm and 100mm, and uses MCP charge signals detected on two orthogonal layers of conductive fingers to encode event X-Y positions. We have achieved spatial resolution XS detectors better than 25 microns FWHM, with good image linearity while at low gain (<10^6), substantially increasing local counting rate capabilities and the overall tube lifetime. XS tubes with updated electronics can encode event rates of >5 MHz with ~12% dead time and event timing accuracy of ~100ps. XDL sealed tubes in 25mm format demonstrate ~40 micron spatial resolution at up to ~2 MHz event rates, and have been developed with SupergenII visible regime photocathodes. The XDL tubes also achieve ~100 ps time resolution. Most

  10. High resolution image of the Lithosphere-Asthenosphere Boundary of the subducting Nazca plate beneath northern Chile

    NASA Astrophysics Data System (ADS)

    Sodoudi, F.; Yuan, X.; Asch, G.; Kind, R.

    2010-12-01

    Results obtained from S and P receiver functions produced a clear image of the top and bottom of the subducting Nazca lithosphere beneath northern Chile. Using data from the teleseismic events recorded at 15 permanent IPOC (Integrated Plate boundary Observatory Chile) stations, we were able to obtain new constraints on the shape and thickness of the descending Nazca lithosphere. We observed the subducted crust of the Nazca plate at depths ranging from 40 km beneath the Coastal Cordillera down to 110 km beneath the Western Cordillera. We found significant along-strike variations in the geometry of the Nazca plate beneath northern Chile. On closer inspection, it appears that the oceanic Nazca plate is divided into two distinct segments as it descends beneath the continental South American plate. The transition from the relatively steeper and deeper slab to the north of 21° S to the flatter southern segment is shown reasonably clearly by our data. This feature could well be associated with variations in the curvature of the plate margin and the geometry of the Chile trench, which is mainly curved to the north of 21° S. We have also mapped the continental Moho of the South American plate at depths ranging between 60-70 km to the east of the Longitudinal Valley. Beneath the Coastal Cordillera, this boundary becomes invisible, probably due to the serpentinization of the forearc mantle wedge. The Lithosphere-Astheonsphere Boundary (LAB) of the subducted Nazca plate was clearly identified as a sharp boundary in the results obtained from the P and S receiver functions. The LAB lies at a depth of 80 km beneath the coastal area and dips from a depth of 100 km beneath the Coastal Cordillera to about 150 km underneath the Western Cordillera. High frequency PRF data enabled us to make confident estimates of the top and bottom of the Nazca lithosphere, which results in a lithospheric thickness of 57-60 km. In relation to the age of the Nazca plate, which is assumed to be ~ 50

  11. An image warping technique for rodent brain MRI-histology registration based on thin-plate splines with landmark optimization

    NASA Astrophysics Data System (ADS)

    Liu, Yutong; Uberti, Mariano; Dou, Huanyu; Mosley, R. Lee; Gendelman, Howard E.; Boska, Michael D.

    2009-02-01

    Coregistration of in vivo magnetic resonance imaging (MRI) with histology provides validation of disease biomarker and pathobiology studies. Although thin-plate splines are widely used in such image registration, point landmark selection is error prone and often time-consuming. We present a technique to optimize landmark selection for thin-plate splines and demonstrate its usefulness in warping rodent brain MRI to histological sections. In this technique, contours are drawn on the corresponding MRI slices and images of histological sections. The landmarks are extracted from the contours by equal spacing then optimized by minimizing a cost function consisting of the landmark displacement and contour curvature. The technique was validated using simulation data and brain MRI-histology coregistration in a murine model of HIV-1 encephalitis. Registration error was quantified by calculating target registration error (TRE). The TRE of approximately 8 pixels for 20-80 landmarks without optimization was stable at different landmark numbers. The optimized results were more accurate at low landmark numbers (TRE of approximately 2 pixels for 50 landmarks), while the accuracy decreased (TRE approximately 8 pixels for larger numbers of landmarks (70- 80). The results demonstrated that registration accuracy decreases with the increasing landmark numbers offering more confidence in MRI-histology registration using thin-plate splines.

  12. Trabecular bone characterization on the continuum of plates and rods using in vivo MR imaging and volumetric topological analysis

    NASA Astrophysics Data System (ADS)

    Chen, Cheng; Jin, Dakai; Liu, Yinxiao; Wehrli, Felix W.; Chang, Gregory; Snyder, Peter J.; Regatte, Ravinder R.; Saha, Punam K.

    2016-09-01

    Osteoporosis is associated with increased risk of fractures, which is clinically defined by low bone mineral density. Increasing evidence suggests that trabecular bone (TB) micro-architecture is an important determinant of bone strength and fracture risk. We present an improved volumetric topological analysis algorithm based on fuzzy skeletonization, results of its application on in vivo MR imaging, and compare its performance with digital topological analysis. The new VTA method eliminates data loss in the binarization step and yields accurate and robust measures of local plate-width for individual trabeculae, which allows classification of TB structures on the continuum between perfect plates and rods. The repeat-scan reproducibility of the method was evaluated on in vivo MRI of distal femur and distal radius, and high intra-class correlation coefficients between 0.93 and 0.97 were observed. The method’s ability to detect treatment effects on TB micro-architecture was examined in a 2 years testosterone study on hypogonadal men. It was observed from experimental results that average plate-width and plate-to-rod ratio significantly improved after 6 months and the improvement was found to continue at 12 and 24 months. The bone density of plate-like trabeculae was found to increase by 6.5% (p  =  0.06), 7.2% (p  =  0.07) and 16.2% (p  =  0.003) at 6, 12, 24 months, respectively. While the density of rod-like trabeculae did not change significantly, even at 24 months. A comparative study showed that VTA has enhanced ability to detect treatment effects in TB micro-architecture as compared to conventional method of digital topological analysis for plate/rod characterization in terms of both percent change and effect-size.

  13. Trabecular bone characterization on the continuum of plates and rods using in vivo MR imaging and volumetric topological analysis.

    PubMed

    Chen, Cheng; Jin, Dakai; Liu, Yinxiao; Wehrli, Felix W; Chang, Gregory; Snyder, Peter J; Regatte, Ravinder R; Saha, Punam K

    2016-09-21

    Osteoporosis is associated with increased risk of fractures, which is clinically defined by low bone mineral density. Increasing evidence suggests that trabecular bone (TB) micro-architecture is an important determinant of bone strength and fracture risk. We present an improved volumetric topological analysis algorithm based on fuzzy skeletonization, results of its application on in vivo MR imaging, and compare its performance with digital topological analysis. The new VTA method eliminates data loss in the binarization step and yields accurate and robust measures of local plate-width for individual trabeculae, which allows classification of TB structures on the continuum between perfect plates and rods. The repeat-scan reproducibility of the method was evaluated on in vivo MRI of distal femur and distal radius, and high intra-class correlation coefficients between 0.93 and 0.97 were observed. The method's ability to detect treatment effects on TB micro-architecture was examined in a 2 years testosterone study on hypogonadal men. It was observed from experimental results that average plate-width and plate-to-rod ratio significantly improved after 6 months and the improvement was found to continue at 12 and 24 months. The bone density of plate-like trabeculae was found to increase by 6.5% (p  =  0.06), 7.2% (p  =  0.07) and 16.2% (p  =  0.003) at 6, 12, 24 months, respectively. While the density of rod-like trabeculae did not change significantly, even at 24 months. A comparative study showed that VTA has enhanced ability to detect treatment effects in TB micro-architecture as compared to conventional method of digital topological analysis for plate/rod characterization in terms of both percent change and effect-size.

  14. Virtual Observatory: Plate Content Digitization, Archive Mining and Image Sequence Processing, , COST Action 283, in the Einstein Year of Physics, 2005

    NASA Astrophysics Data System (ADS)

    Murtagh, F.

    2006-04-01

    Linking Virtual Observatory: Plate Content Digitization, Archive Mining and Image Sequence Processing, to important historical events, in particular relating to anniversaries in 2005, we describe its work, which is centered around the axes of signal and information.

  15. Development of a soft x-ray plasma camera with a Fresnel zone plate to image laser produced plasmas

    NASA Astrophysics Data System (ADS)

    Kado, M.; Mori, M.; Nishiuchi, M.; Ishino, M.; Kawachi, T.

    2009-09-01

    A soft x-ray plasma camera operated at 3.35nm in the water window x-ray region is developed and demonstrated imaging gas jet plasmas of several spices produced with a 10TW Ti: sapphire laser. The plasma camera consists of a 300nm thick Ag/Ti/Si3N4 x-ray band pass filter with bandwidth of 1.43nm to cut visible light and also to reduce colour aberration of the Fresnel zone plate, a Fresnel zone plate with diameter of 1mm and outermost zone width of 300nm, and a soft x-ray CCD camera. The magnification of the plasma camera is 10. The soft x-ray plasma camera powered by a Fresnel zone plate is a very powerful tool to observe laser produced plasmas since it is 1000 times brighter and has 5 times higher spatial resolution comparing ordinary x-ray pinhole camera. The soft x-ray images of helium, nitrogen, argon, krypton, and xenon gas jet plasmas are obtained changing gas pressure from 0.01MPa to 1MPa.

  16. Electromagnetic imaging the of the Pacific-North American plate boundary in central California, USA

    NASA Astrophysics Data System (ADS)

    Wheelock, B. D.; Constable, S.; Key, K. W.

    2010-12-01

    The continental margin of central California lies adjacent to a segment of the San Andreas fault (SAF) that exhibits a transition between locked behavior south of the town of Cholame, and freely slipping (creeping) behavior north of the town of Parkfield. Recent reports of non-volcanic tremor (NVT) near the town of Cholame represent the first observation of NVT in a strike-slip environment. Dense clusters of tremor episodes located at the northern limit of the locked section of the SAF were found to originate within the ductile lower crust at depths between 15 and 30~km, and have been interpreted as evidence of high pore fluid pressure. An excess of fluids in this region is likely given its history of subduction, which transports large quantities of water into the forearc crust and mantle. We present a study that uses deep electromagnetic imaging methods to estimate the abundance and distribution of pore fluids at depths associated with non-volcanic tremor. This study extends a previously collected terrestrial profile of magnetotelluric (MT) data (Becken et al. 2008, Geophysical Journal International) into the offshore environment. We deployed 21 seafloor instruments that collected controlled-source electromagnetic (CSEM) and MT data in a line extending from the coast near Morro Bay, across the continental shelf, and out onto the Pacific plate. The marine MT data results in apparent resistivity and phase estimates at periods between 1~s and 20,000~s, sufficient for probing the upper 100~km of regional conductivity. A significant coast effect, marked by asymptotic behavior in the TE mode of the MT responses, is observed at the deep water sites. This necessitates accurate bathymetry modeling when inverting. The CSEM transmitter was towed by all receivers broadcasting a compact broadband binary waveform with a 0.25~Hz fundamental frequency. The controlled-source signal is observed above the noisefloor at source-receiver offsets up to 6~km, which provides constraints

  17. Image-based ELISA on an activated polypropylene microtest plate--a spectrophotometer-free low cost assay technique.

    PubMed

    Parween, Shahila; Nahar, Pradip

    2013-10-15

    In this communication, we report ELISA technique on an activated polypropylene microtest plate (APPµTP) as an illustrative example of a low cost diagnostic assay. Activated test zone in APPµTP binds a capture biomolecule through covalent linkage thereby, eliminating non-specific binding often prevalent in absorption based techniques. Efficacy of APPµTP is demonstrated by detecting human immunoglobulin G (IgG), human immunoglobulin E (IgE) and Aspergillus fumigatus antibody in patient's sera. Detection is done by taking the image of the assay solution by a desktop scanner and analyzing the color of the image. Human IgE quantification by color saturation in the image-based assay shows excellent correlation with absorbance-based assay (Pearson correlation coefficient, r=0.992). Significance of the relationship is seen from its p value which is 4.087e-11. Performance of APPµTP is also checked with respect to microtiter plate and paper-based ELISA. APPµTP can quantify an analyte as precisely as in microtiter plate with insignificant non-specific binding, a necessary prerequisite for ELISA assay. In contrast, paper-ELISA shows high non-specific binding in control sera (false positive). Finally, we have carried out ELISA steps on APPµTP by ultrasound waves on a sonicator bath and the results show that even in 8 min, it can convincingly differentiate a test sample from a control sample. In short, spectrophotometer-free image-based miniaturized ELISA on APPµTP is precise, reliable, rapid, and sensitive and could be a good substitute for conventional immunoassay procedures widely used in clinical and research laboratories. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. High energy muon induced radioactive nuclides in nickel plate and its use for 2-D muon-beam image profile

    NASA Astrophysics Data System (ADS)

    Kurebayashi, Y.; Sakurai, H.; Takahashi, Y.; Doshita, N.; Kikuchi, S.; Tokanai, F.; Horiuchi, K.; Tajima, Y.; Oe, T.; Sato, T.; Gunji, S.; Inui, E.; Kondo, K.; Iwata, N.; Sasaki, N.; Matsuzaki, H.; Kunieda, S.

    2015-11-01

    Target materials were exposed to a muon beam with an energy of 160 GeV/c at the COMPASS experiment line in CERN-SPS to measure the production cross-sections for muon-induced radionuclides. A muon imager containing four nickel plates, each measuring 100 mm×100 mm, exposed to the IP plate successfully detected the muon beam image during an irradiation period of 33 days. The contrasting density rate of the nickel plate was (5.2±0.7)×10-9 PSL/muon per one-day exposure to IP. The image measured 122 mm and 174 mm in horizontal and vertical lengths, respectively, in relation to the surface of the base, indicating that 50±6% of the muon beam flux is confined to an area of 18% of the whole muon beam. The number of muons estimated from the PSL value in the total beam image area (0.81±0.1)×1013 was comparable to the total muon counts of the ion-chamber at the M2 beam line in the CERN-SPS. The production cross-sections of Cr-51, Mn-54, Co-56, Co-57, and Co-58 in nickel were 0.19±0.08, 0.34±0.06, 0.5±0.05, 3.44±0.07, 0.4±0.03 in the unit of mb, respectively, reducing muon associated particles effects. They are approximately 10 times smaller than that a proceeding study by Heisinger et al.

  19. Experience of the Indirect Neutron Radiography Method Based on the X-ray Imaging Plate at CARR

    NASA Astrophysics Data System (ADS)

    Wei, Guohai; Han, Songbai; Wang, Hongli; He, Linfeng; Wang, Yu; Wu, Meimei; Liu, Yuntao; Chen, Dongfeng

    Indirect neutron radiography (INR) experiments by X-ray imaging plate were carried out at the China Advanced Research Reactor (CARR). The key experiment parameters were optimized, especially the exposure time of the neutron converter andimaging plate. The optimized total exposure time is 37.25 min, it is two-fifths of the timebased on the film method under the same experimental conditions. The qualitative and quantitativeinspections were tested with dummy nuclear fuel rods and a water temperaturesensor ofa motor vehicle. The spring in the sensor and the defects of the dummy fuel rod's pellets can be qualitatively detected. The thickness of the tape at one position on the cladding of the dummy nuclear fuel rodwas quantitatively calculated to be 9.57 layers with the relative error of ±4.3%.

  20. Real-time thermal imaging of microwave accelerated metal-enhanced fluorescence (MAMEF) based assays on sapphire plates.

    PubMed

    Previte, Michael J R; Zhang, Yongxia; Aslan, Kadir; Geddes, Chris D

    2007-11-01

    In this paper, we describe an optical geometry that facilitates our further characterization of the temperature changes above silver island films (SiFs) on sapphire plates, when exposed to microwave radiation. Since sapphire transmits IR, we designed an optical scheme to capture real-time temperature images of a thin water film on sapphire plates with and without SiFs during the application of a short microwave pulse. Using this optical scheme, we can accurately determine the temperature profile of solvents in proximity to metal structures when exposed to microwave irradiation. We believe that this optical scheme will provide us with a basis for further studies in designing metal structures to further improve plasmonic-fluorescence clinical sensing applications, such as those used in microwave accelerated metal-enhanced fluorescence (MAMEF).

  1. Magnetic field distribution in the presence of paramagnetic plates in magnetic resonance imaging: a combined numerical and experimental study.

    PubMed

    Mertens, Philipp; Machann, Juergen; Mueller-Bierl, Bernd; Steidle, Guenter; Bellemann, Matthias E; Schick, Fritz

    2008-05-01

    The amount and geometric distribution of paramagnetic components in tissue is considered as the basis of T2*-weighted magnetic resonance imaging (MRI). Such techniques are routinely applied for assessment of iron in parenchymal organs such as the liver (hemosiderosis). Furthermore, susceptibility sensitive MRI is discussed as an alternative method to x-ray techniques for quantitative assessment of paramagnetic spongy bone components in patients with osteoporosis. The presented work is dedicated to systematically examining the possible influences of macroscopic arrangements of paramagnetic plates on the magnetic field. In a theoretical approach magnetic field distribution was simulated applying decomposition of the plates in single dipoles. Plate size and distances between parallel plates, as well as plate orientation with respect to the static field, were varied for these numerical simulations. Experiments on corresponding plate arrangements were carried out on a 3 T whole body MR scanner using the field-sensitive MR sequence technique for B0 field mapping. Further examinations were carried out on a bone preparation of the femur, where T2* maps were measured and analyzed on a pixel-by-pixel basis at two orientations with respect to the static field. A series of experiments were performed using isotropic and anisotropic volume elements in three-dimensional gradient echo sequences. Resulting magnetic field distributions in the experimentally recorded B0 field maps were in good agreement with the numerical simulations. Field distortions dominated in areas close to the plates and especially near the edges. Those areas showed strong local field gradients, leading to pronounced signal dephasing effects. The examination of the bone preparations revealed different T2* values for identical regions in the bone when the orientation of the bone or the pixel geometry was changed with respect to the magnetic field. Those effects amounted to nearly 70% (22.9 ms versus 13.6 ms in

  2. Analysis of the contribution of sedimentation to bacterial mass transport in a parallel plate flow chamber: part II: use of fluorescence imaging.

    PubMed

    Li, Jiuyi; Busscher, Henk J; van der Mei, Henny C; Norde, Willem; Krom, Bastiaan P; Sjollema, Jelmer

    2011-10-15

    Using a new phase-contrast microscopy-based method of analysis, sedimentation has recently been demonstrated to be the major mass transport mechanism of bacteria towards substratum surfaces in a parallel plate flow chamber (J. Li, H.J. Busscher, W. Norde, J. Sjollema, Colloid Surf. B. 84 (2011) 76). Here we describe a novel method for enumerating adhesion of fluorescent bacteria in a parallel plate flow chamber that allows direct imaging of the bacterial distribution along the length of the flow chamber, as caused by sedimentation. Imaging of fluorescence was done using macroscopic bio-optical imaging of the entire flow chamber, including top and bottom plates as well as of the flowing suspension in between. An algorithm is forwarded that allows to separate the fluorescence arising from the suspension and bottom plate and at the same time determines the single cell fluorescence from which the bacterial distribution over the entire bottom plate can be visualized. Enumeration of the numbers of bacteria adhering to the center of the glass bottom plate for a fluorescent Staphylococcus aureus strain was found to coincide with enumerations using phase-contrast microscopy. Moreover, due to the use of macroscopic bio-optical imaging, it was found that the number of adhering staphylococci increases linearly with distance from the inlet of the flow chamber, which could be explained from a simplified mass balance of convection, sedimentation and blocking near the bottom plate of the flow chamber.

  3. Subcellular in vivo time-lapse imaging and optical manipulation of Caenorhabditis elegans in standard multiwell plates.

    PubMed

    Rohde, Christopher B; Yanik, Mehmet Fatih

    2011-01-01

    High-resolution in vivo time-lapse assays require repeated immobilization and imaging of whole animals. Here we report a technology for screening Caenorhabditis elegans at cellular resolution over its entire lifespan inside standard multiwell plates using repeated immobilization, imaging and optical manipulation. Our system does not use any fluidic or mechanical components, and can operate for tens of thousands of cycles without failure. It is also compatible with industrial high-throughput screening platforms and robotics, and it allows both chemical, and forward and reverse genetic screens. We used this technology to perform subcellular-resolution femtosecond laser microsurgery of single neurons in vivo, and to image the subsequent regeneration dynamics at subcellular resolution. Our single-neuron in vivo time-lapse analysis shows that neurite regrowth occurring over short time windows is significantly greater than that predicted by ensemble averaging over many animals.

  4. Multiple damage identification and imaging in an aluminum plate using effective Lamb wave response automatic extraction technology

    NASA Astrophysics Data System (ADS)

    Ouyang, Qinghua; Zhou, Li; Liu, Xiaotong

    2016-04-01

    In order to identify multiple damage in the structure, a method of multiple damage identification and imaging based on the effective Lamb wave response automatic extraction algorithm is proposed. In this method, the detected key area in the structure is divided into a number of subregions, and then, the effective response signals including the structural damage information are automatically extracted from the entire Lamb wave responses which are received by the piezoelectric sensors. Further, the damage index values of every subregion based on the correlation coefficient are calculated using the effective response signals. Finally, the damage identification and imaging are performed using the reconstruction algorithm for probabilistic inspection of damage (RAPID) technique. The experimental research was conducted using an aluminum plate. The experimental results show that the method proposed in this research can quickly and effectively identify the single damage or multiple damage and image the damages clearly in detected area.

  5. Dynamic Characterizations of an 8-frame Half-Strip High-speed X-ray Microchannel Plate Imager

    SciTech Connect

    Ken Moy, Ming Wu, Craig Kruschwitz, Aric Tibbits, Matt Griffin, Greg Rochau

    2008-09-05

    High-speed microchannel plate (MCP)–based imagers are critical detectors for x-ray diagnostics employed on Z-experiments at Sandia National Laboratories (SNL) to measure time-resolved x-ray spectra and to image dynamic hohlraums. A multiframe design using eight half strips in one imager permits recordings of radiation events in discrete temporal snapshots to yield a time-evolved movie. We present data using various facilities to characterize the performance of this design. These characterization studies include DC and pulsed-voltage biased measurements in both saturated and linear operational regimes using an intense, short-pulsed UV laser. Electrical probe measurements taken to characterize the shape of the HV pulse propagating across the strips help to corroborate the spatial gain dependence.

  6. High-resolution imaging X-ray detector. [using microchannel plates and electronic readout for spaceborne telescope

    NASA Technical Reports Server (NTRS)

    Kellogg, E.; Henry, P.; Murray, S.; Van Speybroeck, L.; Bjorkholm, P.

    1976-01-01

    The paper describes an X-ray detector using microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. The position resolution is 10 microns. The crossed wire grid consists of 100-micron-diam wires on 200-micron centers. Position sensing is accomplished by electronic interpolation to 1/20 of the wire spacing. The quantum efficiency of the microchannel plates varies from 29% at 0.28 keV to 5% at 3 keV. This detector will provide second-of-arc X-ray imaging in the focal plane of the 342.9-cm focal length grazing-incidence telescope being prepared for the HEAO-B observatory. By addition of suitable photocathodes, it can be used for single-photon imaging light detection in the UV, visible, and near-IR-ranges. In all cases, it gives a very low dark counting rate, allows timing of individual events to 1 microsec or less, and can handle counting rates up to 10,000 per sec.

  7. High-resolution imaging X-ray detector. [using microchannel plates and electronic readout for spaceborne telescope

    NASA Technical Reports Server (NTRS)

    Kellogg, E.; Henry, P.; Murray, S.; Van Speybroeck, L.; Bjorkholm, P.

    1976-01-01

    The paper describes an X-ray detector using microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. The position resolution is 10 microns. The crossed wire grid consists of 100-micron-diam wires on 200-micron centers. Position sensing is accomplished by electronic interpolation to 1/20 of the wire spacing. The quantum efficiency of the microchannel plates varies from 29% at 0.28 keV to 5% at 3 keV. This detector will provide second-of-arc X-ray imaging in the focal plane of the 342.9-cm focal length grazing-incidence telescope being prepared for the HEAO-B observatory. By addition of suitable photocathodes, it can be used for single-photon imaging light detection in the UV, visible, and near-IR-ranges. In all cases, it gives a very low dark counting rate, allows timing of individual events to 1 microsec or less, and can handle counting rates up to 10,000 per sec.

  8. A Novel Evaluation Method for Displacement between Carbon Beam Axis and Positioning X-ray Axis Using an Imaging Plate.

    PubMed

    Kurosawa, Yuji; Kubota, Yoshiki; Takeshita, Eri; Okada, Ryosuke; Ohashi, Yoshiaki; Souda, Hikaru; Ishii, Takayoshi; Sutou, Takayuki; Kanai, Tatsuaki; Ohno, Tatsuya; Nakano, Takashi

    2016-02-01

    We developed an evaluation method for easily calculating displacement directly between the carbon beam axis and positioning X-ray axis. A verification image was acquired by irradiating an imaging plate with a carbon beam and X-ray. The X-ray passed through a lead plate inserted in the range compensator holder. The displacement was calculated on the verification image from the center of a wire irradiated with carbon using a multi leaf collimator (MLC) and a wire irradiated with X-ray also using MLC. The accuracy of the method was evaluated by moving the carbon beam axis, the X-ray axis, and the setup angle. The weekly changes of vertical and lateral beams in all rooms were also evaluated. The displacements of the carbon beam axis and the setup angle did not influence the calculation results, whereas the displacement of the X-ray axis did (R=0.999). The displacements including weekly changes were all less than 1.00 mm. An evaluation method for calculating the displacement directly and simply between the carbon beam axis and positioning X-ray axis was developed and verified. The weekly changes of displacement between axes were evaluated to be acceptable at our facility.

  9. Multichannel Seismic Imaging of the Rivera Plate Subduction at the Seismogenic Jalisco Block Area (Western Mexican Margin)

    NASA Astrophysics Data System (ADS)

    Bartolome, Rafael; Górriz, Estefanía; Dañobeitia, Juanjo; Cordoba, Diego; Martí, David; Cameselle, Alejandra L.; Núñez-Cornú, Francisco; Bandy, William L.; Mortera-Gutiérrez, Carlos A.; Nuñez, Diana; Castellón, Arturo; Alonso, Jose Luis

    2016-10-01

    During the TSUJAL marine geophysical survey, conducted in February and March 2014, Spanish, Mexican and British scientists and technicians explored the western margin of Mexico, considered one of the most active seismic zones in America. This work aims to characterize the internal structure of the subduction zone of the Rivera plate beneath the North American plate in the offshore part of the Jalisco Block, to link the geodynamic and the recent tectonic deformation occurring there with the possible generation of tsunamis and earthquakes. For this purpose, it has been carried out acquisition, processing and geological interpretation of a multichannel seismic reflection profile running perpendicular to the margin. Crustal images show an oceanic domain, dominated by subduction-accretion along the lower slope of the margin with a subparallel sediment thickness of up to 1.6 s two-way travel time (approx. 2 km) in the Middle American Trench. Further, from these data the region appears to be prone to giant earthquake production. The top of the oceanic crust (intraplate reflector) is very well imaged. It is almost continuous along the profile with a gentle dip (<10°); however, it is disrupted by normal faulting resulting from the bending of the plate during subduction. The continental crust presents a well-developed accretionary prism consisting of highly deformed sediments with prominent slumping towards the trench that may be the result of past tsunamis. Also, a bottom simulating reflector (BSR) is identified in the first half a second (twtt) of the section. High amplitude reflections at around 7-8 s twtt clearly image a discontinuous Moho, defining a very gentle dipping subduction plane.

  10. Multichannel Seismic Imaging of the Rivera Plate Subduction at the Seismogenic Jalisco Block Area (Western Mexican Margin)

    NASA Astrophysics Data System (ADS)

    Bartolome, R.; Gorriz, E.; Danobeitia, J.; Barba, D. C., Sr.; Martí, D.; L Cameselle, A.; Nuñez-Cornu, F. J.; Bandy, W. L.; Mortera, C.; Nunez, D.; Alonso, J. L.; Castellon, A.; Prada, M.

    2016-12-01

    During the TSUJAL marine geophysical survey, conducted in February and March 2014 Spanish, Mexican and British scientists and technicians explored the western margin of Mexico, considered one of the most active seismic zones in America. This work aims to characterize the internal structure of the subduction zone of the Rivera plate beneath the North American plate in the offshore part of the Jalisco Block, to link the geodynamic and the recent tectonic deformation occurring there with the possible generation of tsunamis and earthquakes. For this purpose, it has been carried out acquisition, processing and geological interpretation of a multichannel seismic reflection profile running perpendicular to the margin. Crustal images show an oceanic domain, dominated by subduction-accretion along the lower slope of the margin with a subparallel sediment thickness of up to 1.6 s two way travel time (approx. 2 km) in the Middle American Trench. Further, from these data the region appears to be prone to giant earthquake production. The top of the oceanic crust (intraplate reflector) is very well imaged. It is almost continuous along the profile with a gentle dip (<10°); however, it is disrupted by normal faulting resulting from the bending of the plate during subduction. The continental crust presents a well-developed accretionary prism consisting of highly deformed sediments with prominent slumping towards the trench that may be the result of past tsunamis. Also, a Bottom Simulating Reflector (BSR) is identified in the first half a second (twtt) of the section. High amplitude reflections at around 7-8 s twtt clearly image a discontinuous Moho, defining a very gentle dipping subduction plane.

  11. Measurement of spatial distribution of neutrons and gamma rays for BNCT using multi-imaging plate system.

    PubMed

    Tanaka, Kenichi; Sakurai, Yoshinori; Tanaka, Hiroki; Kajimoto, Tsuyoshi; Takata, Takushi; Takada, Jun; Endo, Satoru

    2015-12-01

    Quality assurance of the spatial distributions of neutrons and gamma rays was tried using imaging plates (IPs) and converters to enhance the beam components in the epithermal neutron mode of the Kyoto University Reactor. The converters used were 4mm thick epoxy resin with B4C at 6.85 weight-percent (wt%) (10)B for epithermal neutrons, and 3mm thick carbon for gamma rays. Results suggested that the IP signal does not need a sensitivity correction regardless of the incident radiation that produces it.

  12. Creation of storage centers in CsBr:Eu{sup 2+} needle image plates by vacuum ultraviolet radiation

    SciTech Connect

    Weidner, M.; Batentschuk, M.; Osvet, A.; Winnacker, A.; Tahon, J. P.; Leblans, P.

    2009-09-15

    In this study, the photostimulated luminescence of the CsBr:Eu{sup 2+} needle image plates (NIPS) after vacuum ultraviolet (VUV) irradiation and their photoluminescence under VUV and UV excitation were investigated. It was shown that the photostimulable storage centers arise almost exclusively due to irradiation of the CsBr:Eu NIPs in the spectral lines of creation of the 4p{sup 5}5s anion excitons, and not in the region of interband transitions of CsBr. The explanation of the results is based mainly on the radiative and nonradiative decay of the self-localized e+Br{sub 2}{sup -} excitons.

  13. Poster — Thur Eve — 02: Measurement of CT radiation profile width using Fuji CR imaging plate raw data

    SciTech Connect

    Bjarnason, T A; Yang, C J

    2014-08-15

    Measuring the CT collimation width and assessing the shape of the overall profile is a relatively straightforward quality control (QC) measure that impacts both image quality and patient dose, and is often required at acceptance and routine testing. Most CT facilities have access to computed radiography (CR) systems, so performing CT collimation profile assessments using CR plates requires no additional equipment. Previous studies have shown how to effectively use CR plates to measure the radiation profile width. However, a major limitation of the previous work is that the full dynamic range of CR detector plates are not used, since the CR processing technology reduces the dynamic range of the DICOM output to 2{sup 10}, requiring the sensitivity and latitude settings of CR reader to be adjusted to prevent clipping of the CT profile data. Such adjustments to CR readers unnecessarily complicate the QC procedure. These clipping artefacts hinder the ability to accurately assess CT collimation width because the full-width at half maximum value of the penumbras are not properly determined if the maximum dose of the profile is not available. Furthermore, any inconsistencies in the radiation profile shape are lost if the profile plateau is clipped off. In this work we developed an opensource Matlab script for straightforward CT profile width measurements using raw CR data that also allows assessment of the profile shape without clipping, and applied this approach during CT QC.

  14. Antiproton, positron, and electron imaging with a microchannel plate/phosphor detector

    NASA Astrophysics Data System (ADS)

    Andresen, G. B.; Bertsche, W.; Bowe, P. D.; Bray, C. C.; Butler, E.; Cesar, C. L.; Chapman, S.; Charlton, M.; El Nasr, S. Seif; Fajans, J.; Fujiwara, M. C.; Gill, D. R.; Hangst, J. S.; Hardy, W. N.; Hayano, R. S.; Hayden, M. E.; Humphries, A. J.; Hydomako, R.; Jørgensen, L. V.; Kerrigan, S. J.; Kurchaninov, L.; Lambo, R.; Madsen, N.; Nolan, P.; Olchanski, K.; Olin, A.; Povilus, A. P.; Pusa, P.; Sarid, E.; Silveira, D. M.; Storey, J. W.; Thompson, R. I.; van der Werf, D. P.; Yamazaki, Y.; Alpha Collaboration

    2009-12-01

    A microchannel plate (MCP)/phosphor screen assembly has been used to destructively measure the radial profile of cold, confined antiprotons, electrons, and positrons in the ALPHA experiment, with the goal of using these trapped particles for antihydrogen creation and confinement. The response of the MCP to low energy (10-200 eV, <1 eV spread) antiproton extractions is compared to that of electrons and positrons.

  15. Antiproton, positron, and electron imaging with a microchannel plate/phosphor detector

    SciTech Connect

    Andresen, G. B.; Bowe, P. D.; Hangst, J. S.; Bertsche, W.; Butler, E.; Charlton, M.; Humphries, A. J.; Joergensen, L. V.; Kerrigan, S. J.; Madsen, N.; Werf, D. P. van der; Bray, C. C.; Chapman, S.; Fajans, J.; Povilus, A. P.; Cesar, C. L.; Lambo, R.; Fujiwara, M. C.; Gill, D. R.; Collaboration: ALPHA Collaboration; and others

    2009-12-15

    A microchannel plate (MCP)/phosphor screen assembly has been used to destructively measure the radial profile of cold, confined antiprotons, electrons, and positrons in the ALPHA experiment, with the goal of using these trapped particles for antihydrogen creation and confinement. The response of the MCP to low energy (10-200 eV, <1 eV spread) antiproton extractions is compared to that of electrons and positrons.

  16. X-ray Phase Imaging Microscopy using a Fresnel Zone Plate and a Transmission Grating

    SciTech Connect

    Yashiro, Wataru; Momose, Atsushi; Takeuchi, Akihisa; Suzuki, Yoshio

    2010-06-23

    We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.

  17. Rapid and simultaneous in situ assessment of aflatoxins and stilbenes using silica plate imprinting mass spectrometry imaging.

    PubMed

    de Oliveira, Diogo N; Ferreira, Mônica S; Catharino, Rodrigo R

    2014-01-01

    A fast and direct combination of techniques for simultaneous mycotoxin and phytoalexin identification in peanut skin and kernel is described. Silica Plate Imprinting Laser Desorption/Ionization Mass Spectrometry Imaging (SPILDI-MSI) is a powerful technique that exhibits great advantages, such as solvent-free and matrix-free characteristics, as well as no sample preparation or separation steps. It also permits accurate identification of mycotoxins and phytoalexins with unique fingerprint profiles in just a few seconds. Results are expressed as chemical images of the 4 identified types of aflatoxins (B1, B2, G1 and G2) and a stilbenoid (resveratrol). Also, SPILDI-MSI allows the comparison between the spatial distribution of aflatoxins and resveratrol found in kernel and skin. This novel application has proven to be useful for instantaneous qualitative assessment of aflatoxins and stilbenoids both in the peanut skin and kernel and offers precise tracking of fungal contamination in nuts and other foodstuffs.

  18. Rapid and Simultaneous In Situ Assessment of Aflatoxins and Stilbenes Using Silica Plate Imprinting Mass Spectrometry Imaging

    PubMed Central

    de Oliveira, Diogo N.; Ferreira, Mônica S.; Catharino, Rodrigo R.

    2014-01-01

    A fast and direct combination of techniques for simultaneous mycotoxin and phytoalexin identification in peanut skin and kernel is described. Silica Plate Imprinting Laser Desorption/Ionization Mass Spectrometry Imaging (SPILDI-MSI) is a powerful technique that exhibits great advantages, such as solvent-free and matrix-free characteristics, as well as no sample preparation or separation steps. It also permits accurate identification of mycotoxins and phytoalexins with unique fingerprint profiles in just a few seconds. Results are expressed as chemical images of the 4 identified types of aflatoxins (B1, B2, G1 and G2) and a stilbenoid (resveratrol). Also, SPILDI-MSI allows the comparison between the spatial distribution of aflatoxins and resveratrol found in kernel and skin. This novel application has proven to be useful for instantaneous qualitative assessment of aflatoxins and stilbenoids both in the peanut skin and kernel and offers precise tracking of fungal contamination in nuts and other foodstuffs. PMID:24595464

  19. Strain Library Imaging Protocol for high-throughput, automated single-cell microscopy of large bacterial collections arrayed on multiwell plates.

    PubMed

    Shi, Handuo; Colavin, Alexandre; Lee, Timothy K; Huang, Kerwyn Casey

    2017-02-01

    Single-cell microscopy is a powerful tool for studying gene functions using strain libraries, but it suffers from throughput limitations. Here we describe the Strain Library Imaging Protocol (SLIP), which is a high-throughput, automated microscopy workflow for large strain collections that requires minimal user involvement. SLIP involves transferring arrayed bacterial cultures from multiwell plates onto large agar pads using inexpensive replicator pins and automatically imaging the resulting single cells. The acquired images are subsequently reviewed and analyzed by custom MATLAB scripts that segment single-cell contours and extract quantitative metrics. SLIP yields rich data sets on cell morphology and gene expression that illustrate the function of certain genes and the connections among strains in a library. For a library arrayed on 96-well plates, image acquisition can be completed within 4 min per plate.

  20. Middle infrared hyperspectral imaging of adhesives, varnishes and inks on Al plate and papers by using a bolometer camera and an imaging type interferometer

    NASA Astrophysics Data System (ADS)

    Sugawara, Shigeru; Yoshida, Mitsuhiro; Saito, Tsubasa; Nakayama, Yoshihiko; Tsutsui, Yasuyuki; Taniguchi, Hideya; Ishimaru, Ichiro

    2016-10-01

    We built a hyperspectral imaging apparatus using middle-infrared light of 8-14 μm, which has a strong ability to identify organic materials, and attempted visualization of the distribution of organic materials that could not be identified by a naked eye. For this purpose, we utilized a low-cost bolometer camera (Nippon Avionics co., ltd. C100V, Japan) for its easy availability rather than an expensive mercury cadmium telluride (MCT) array sensor. To compensate for the low sensitivity of this bolometer, we adopted a Fourier-type spectroscopic system (Aoi Electronics co. ltd., Japan) using an imaging interferometer devised by the Kagawa University, Japan; this interferometer has higher light-utilization efficiency than Michelson interferometers, which are used in popular interferometry techniques. In this study, 4 types of adhesives, 9 types of varnishes and more than 50 types of inks were put on Al plates of size 10 cm × 10 cm and were used as samples. Glossy paper for printing photos with an inkjet printer was also used as a sample. A 300 °C black body of size 15 cm × 15 cm was used as a light source. Spectra of 320 × 240 points were measured at a wavelength resolution of approximately 9 cm-1. The mirror was scanned only once. The measurement time was approximately 30 s. Hyperspectral images of adhesives, varnishes and inks on Al plate and paper were successfully measured. Spectra over a 5 × 5-pixel neighborhoods were averaged, and the averaged spectra were compared with those measured by a commercially available Fourier transform infrared (FTIR) spectroscopy. The averaged and measured spectra had absorption peaks at the same wavelengths. Furthermore, by analyzing the measured spectra, the distribution of substances invisible to the naked eye was visualized. Our results show that if low-absorbance organic materials are put on a high-reflectance surface such as an Al plate, the middle-infrared hyperspectral imaging could be measured using a bolometer

  1. Evaluation of relative speed of latent images in relation to changes in fading time and storage temperature of imaging plates in computed radiography systems.

    PubMed

    Seoung, Youl-Hun

    2014-01-01

    This study aimed to evaluate the relative speed (RS) of latent images in relation to changes in the fading time and storage temperature of imaging plates (IPs) in computed radiography systems. The storage temperatures adopted were 20, 30, and 40°C, while the fading times employed were 0, 4, 8, 12, and 24 hours. The X-ray exposure factors were 50 kVp, 10 mAs, and a 150 cm distance from an IP to an X-ray source. In the processing of each image, the parameters used for multi-scale image contrast amplification were multiscale image contrast, noise reduction, edge enhancement, and latitude reduction, all assigned a value of 0. Image sensitivity was used to convert linear properties. The RS used for the characteristic curve was evaluated using a uniform aluminum 11-step wedge. Results show that the RS values of IPs with changing fading time were 17.8 ± 0.9 at 20°C, 13.9 ± 1.1 at 30°C, and 13.4 ± 0.9 at 40°C. On the basis of these findings, we conclude that IPs should be stored in the long term at temperatures as low as 20°C.

  2. New seismic images of the crust across the Rivera Plate and Jalisco Block (Mexico)

    NASA Astrophysics Data System (ADS)

    Cordoba, Diego; Núñez-Cornú, Francisco Javier; Bartolomé, Rafael; José Dañobeitia, Juan; Bandy, William Lee; Núñez, Diana; Prada, Manel; Escudero-Ayala, Christian; Espíndola, Juan Manuel; Zamora, Araceli; Gómez, Adán; Ortiz, Modesto; Tsujal Working Group

    2015-04-01

    During the spring and summer of 2014, we achieved an extensive offshore geophysical experiment at West Coast of México entitled "Crustal characterization of the Rivera Plate-Jalisco Block boundary and its implications for seismic and tsunami hazard assessment (TSUJAL)". The project is the result of continuous scientific collaboration between institutions in Mexico and Spain, whose main objective is to study the lithospheric structure at the collision zone between Rivera, North America Plates and the Jalisco Block, and identifying submarine structures which can potentially be tsunamigenic sources The active phase of this project carried out in February and March of 2014, we acquired around 5200 km of Multichannel Seismic Reflection (MCS) together with multibeam bathymetry and potential fields (gravity and magnetism) data. Moreover, a wide angle experiment was performed, deploying 16 OBS in 32 locations in Jalisco and Nayarit offshore regions, also recorded on a terrestrial network of 100 portable seismic stations in 240 locations across 5 seismic profiles of 200-300 km in length combined with the Seismological Network of the State of Jalisco (SisVOc). In addition, 8 land seismic stations were installed in Marías Islands and Isabel Island. These instruments registered, in continuous mode, the airgun shots generated by airgun array of 5800 ci, shooting every 120 s. The UK vessel RRS James Cook participated in this project as a part of the exchange program between Spanish and English scientific vessels, she was responsible of marine seismic experiment (MCS & WA) using a 6 km length streamer and a high capacity airgun array. Furthermore, the ARM Holzinger and RV El Puma participated in this project and were provided by the Mexican Navy and UNAM, respectively. The second phase of this project was achieved in June 2014, where 100 short period seismic stations were installed along a 200 km seismic profile from La Caldera de la Primavera (Guadalajara) to Barra de Navidad

  3. Circular multilayer zone plate for high-energy x-ray nano-imaging

    SciTech Connect

    Koyama, Takahisa; Takano, Hidekazu; Konishi, Shigeki; Tsuji, Takuya; Kagoshima, Yasushi; Takenaka, Hisataka; Ichimaru, Satoshi; Ohchi, Tadayuki

    2012-01-15

    A circular multilayer zone plate (MZP) was fabricated and its focusing performance was evaluated using 20-keV x-rays. MoSi{sub 2} and Si layers were alternately deposited by DC magnetron sputtering on a wire core; all the interfaces satisfied the Fresnel zone condition. The measured line spread function was converted to a point spread function by tomographic reconstruction. The results suggest that the MZP has the potential to realize the diffraction-limited resolving power, which is calculated to be 35 nm using the diffraction integral. Furthermore, scanning transmission microscopy using the MZP could resolve a 50-nm line-and-space pattern.

  4. Temperature dependence of Eu-related EPR spectra in CsBr:Eu needle image plates

    SciTech Connect

    Loncke, F.; Vrielinck, H.; Matthys, P.; Callens, F.; Tahon, J.-P.; Leblans, P.; Ahmad, I.; Goovaerts, E.

    2009-05-01

    Vacuum-deposited CsBr needle plates doped with Eu{sup 2+} have been investigated with Q ({approx}34 GHz) and W ({approx}95 GHz) band electron paramagnetic resonance in a large temperature interval (4 K: room temperature). At low temperatures (<35 K), two Eu-related centers were found with different symmetry (tetragonal and orthorhombic), while in earlier studies at room temperature only one center was found with tetragonal symmetry. Possible models for the three defects are investigated, taking into account their temperature behavior, their symmetry, and the atypical values of their zero-field splitting parameters.

  5. Development of Multi-gap Resistive Plate Chamber (MRPC) for medical imaging

    NASA Astrophysics Data System (ADS)

    Banerjee, A.; Roy, A.; Biswas, S.; Chattopadhyay, S.; Das, G.; Pal, S.

    2013-08-01

    The low cost and high resolution Multi-gap Resistive Plate Chamber (MRPC) opens up a new possibility to find an efficient alternative detector for the Time of Flight (TOF) based Positron Emission Tomography, where the sensitivity of the system depends largely on the time resolution of the detector. In a layered structure, suitable converters can be used to increase the photon detection efficiency. In this paper results of the cosmic ray test of a four-gap bakelite-based prototype MRPC operated in streamer mode and six-gap glass-based MRPC operated in avalanche mode are discussed.

  6. Seismic interferometry imaging of subducting Philippine Sea plate and crustal structure in Tokai region, central Japan using natural earthquakes

    NASA Astrophysics Data System (ADS)

    Totani, M.; Watanabe, T.; Yamaoka, K.; Kato, A.; Iidaka, T.; Ikuta, R.; Tsumura, N.; Okubo, M.; Suzuki, S.

    2013-12-01

    Seismic interferometry is an imaging method of subsurface structures using passive seismic records without artificial energy sources. Using natural earthquake records, seismic reflection imaging of deep crustal structures and plate boundaries is expected. We applied seismic interferometry to natural earthquake records, acquired by a wide-aperture linear seismometer array called Tokai Array, to image the P- and S-wave seismic structures in the Tokai region, central Japan. The Tokai Array observation was conducted from April to August 2008 with 81 three-component seismometers spanning about 100km in length. Records of 8 Hi-net stations near the array were also used. At first, we applied auto-correlation analysis to the record of deep earthquakes. Since the auto-correlation analysis assumes one-dimensional wave propagation, we searched deep earthquakes that could be considered as normal incidence using Fresnel zone concept. We selected 13 events of deep earthquakes for the P-wave and 10 events for the S-wave analysis, which occurred along subducting Pacific Sea plate at 200 - 300km in depth. After correcting seismometer response, we applied the band-pass filter from 1.0 to 2.5 Hz and 0.5 to 1.0 Hz for P- and S-wave, respectively, corresponding to the dominant frequency of the seismic records. Then we removed the records showing low S/N ratio. Afterwards, we calculated the auto-correlation to obtain virtual shot record, which is equivalent to zero-offset shot record. We applied a filter that transforms source functions into the simple Ricker wavelet, to remove the effects associated with source functions. After whitening deconvolution to remove multiples, we stacked auto-correlation of every earthquake record, and applied Kirchoff depth migration using the velocity model estimated by seismic tomography method (Kato et al., 2010). The result of auto-correlation analysis shows good agreement with previous researches in the area, such as seismic tomography, receiver

  7. RGB color calibration for quantitative image analysis: the "3D thin-plate spline" warping approach.

    PubMed

    Menesatti, Paolo; Angelini, Claudio; Pallottino, Federico; Antonucci, Francesca; Aguzzi, Jacopo; Costa, Corrado

    2012-01-01

    In the last years the need to numerically define color by its coordinates in n-dimensional space has increased strongly. Colorimetric calibration is fundamental in food processing and other biological disciplines to quantitatively compare samples' color during workflow with many devices. Several software programmes are available to perform standardized colorimetric procedures, but they are often too imprecise for scientific purposes. In this study, we applied the Thin-Plate Spline interpolation algorithm to calibrate colours in sRGB space (the corresponding Matlab code is reported in the Appendix). This was compared with other two approaches. The first is based on a commercial calibration system (ProfileMaker) and the second on a Partial Least Square analysis. Moreover, to explore device variability and resolution two different cameras were adopted and for each sensor, three consecutive pictures were acquired under four different light conditions. According to our results, the Thin-Plate Spline approach reported a very high efficiency of calibration allowing the possibility to create a revolution in the in-field applicative context of colour quantification not only in food sciences, but also in other biological disciplines. These results are of great importance for scientific color evaluation when lighting conditions are not controlled. Moreover, it allows the use of low cost instruments while still returning scientifically sound quantitative data.

  8. Characteristics of unerasable and reappearing photostimulated luminescence signals in over-irradiated imaging plates and a new complete erasing method

    NASA Astrophysics Data System (ADS)

    Ohuchi, Hiroko; Kondo, Yasuhiro

    2008-11-01

    Characteristics of unerasable and reappearing photostimulated luminescence (PSL) signals in an imaging plate (IP) made of europium-doped BaFBr were investigated. It has been empirically known that the phenomena are observed remarkably in IPs irradiated with X-ray doses exceeding 1 mGy. In these over-irradiated IPs, quite stable latent images remain unerasable after fully erasing with visible light and latent images reappear after a while, even after they seem to have been completely erased. The results showed that the amount of reappearing PSL signals was proportional to the delivered dose when irradiated at a fixed dose rate, and it was not dependent on dose rate when irradiated with a fixed dose. The effect of heat on unerasable and reappearing latent PSL signals was examined. Unerasable PSL signals almost disappeared under a temperature of 120 °C over 28 elapsed days; however, a long heating period has also caused deterioration in IP samples. In a study on the effect of light sources on PSL signals using halogen light and fluorescent light, it was found that ultraviolet light around 290 nm promoted the occurrence of reappearing PSL signals that could be easily erased with visible light. This indicates that electrons localized in short wavelengths can be excited optically by an atomic line of mercury and shifted towards longer wavelengths, around 633 nm, causing reappearing latent images. From this result, a new method to completely erase unerasable latent images, i.e., by simultaneously exposing IP samples with an ultraviolet light and a fluorescent light, has been developed. After repeated treatment by this method, unerasable latent images were completely erased without reappearing PSL signals.

  9. [The future of bedside chest radiography: Comparative study of mobile flat-panels and needle-image plate storage phosphor systems].

    PubMed

    Bremicker, K; Gosch, D; Kahn, T; Borte, G

    2015-11-01

    Chest radiography is the most common diagnostic modality in intensive care units with new mobile flat-panels gaining more attention and availability in addition to the already used storage phosphor plates. Comparison of the image quality of mobile flat-panels and needle-image plate storage phosphor system in terms of bedside chest radiography. Retrospective analysis of 84 bedside chest radiographs of 42 intensive care patients (20 women, 22 men, average age: 65 years). All images were acquired during daily routine. For each patient, two images were analyzed, one from each system mentioned above. Two blinded radiologists evaluated the image quality based on ten criteria (e.g., diaphragm, heart contour, tracheal bifurcation, thoracic spine, lung structure, consolidations, foreign material, and overall impression) using a 5-point visibility scale (1 = excellent, 5 = not usable). There was no significant difference between the image quality of the two systems (p < 0.05). Overall some anatomical structures such as the diaphragm, heart, pulmonary consolidations and foreign material were considered of higher diagnostic quality compared to others, e.g., tracheal bifurcation and thoracic spine. Mobile flat-panels achieve an image quality which is as good as those of needle-image plate storage phosphor systems. In addition, they allow immediate evaluation of the image quality but in return are much more expensive in terms of purchase and maintenance.

  10. First inductively coupled plasma-distance-of-flight mass spectrometer: instrument performance with a microchannel plate/phosphor imaging detector

    SciTech Connect

    Gundlach-Graham, Alexander W.; Dennis, Elise; Ray, Steven J.; Enke, Christie G.; Barinaga, Charles J.; Koppenaal, David W.; Hieftje, Gary M.

    2013-09-01

    Here we describe the first combination of a Distance-of-Flight Mass Spectrometry (DOFMS) instrument and an inductively coupled plasma (ICP) ion source. DOFMS is a velocity-based MS technique in which ions of a range of mass-to-charge (m/z) values are detected simultaneously along the length of a spatially selective detector. As a relative of time-of-flight (TOF) MS, DOFMS leverages benefits fromboth TOFMS and spatially dispersive MS. The simultaneous detection of groups of m/z values improves dynamic range by spreading ion signal across many detector elements and reduces correlated noise by signal ratioing. To ascertain the performance characteristics of the ICP-DOFMS instrument, we have employed a microchannel-plate/phosphor detection assembly with a scientific CCD to capture images of the phosphor plate. With this simple (and commercially available) detection scheme, elemental detection limits from 2–30 ng L*1 and a linear dynamic range of 5 orders of magnitude (10–106 ng L1) have been demonstrated. Additionally, a competitive isotope-ratio precision of 0.1% RSD has been achieved with only a 6 s signal integration period. In addition to first figures of merit, this paper outlines technical considerations for the design of the ICP-DOFMS.

  11. Analysis of phenolics in wine by high performance thin-layer chromatography with gradient elution and high resolution plate imaging.

    PubMed

    Agatonovic-Kustrin, Snezana; Hettiarachchi, Chandima G; Morton, David W; Razic, Slavica

    2015-01-01

    Health benefits of wine, especially with red wine, have been linked to the presence of a wide range of phenolic antioxidants. Thus, the aim of this study was to develop a simple, high performance thin layer chromatographic (HPTLC) method combined with high resolution digital plate images to visually compare multiple wine samples simultaneously on a single chromatographic plate and to quantify levels of gallic acid, caffeic acid, resveratrol and rutin, as representatives of the four different classes of phenolics found in wines. We also wanted to investigate the contribution of the investigated phenolic compounds to the total polyphenolic content (TPC) and total antioxidant capacity (TAC) of the wine samples. The average concentrations of caffeic acid, gallic acid, resveratrol, and rutin in the red wines were 2.15, 30.17, 0.59 and 2.47 mg/L respectively with their concentration below limit of quantification in the white wine samples. The highest concentration of resveratrol and rutin is found in the Cabernet and Shiraz wine samples. The amounts of gallic acid are correlated with TPC (r=0.58). Italian wines have the highest correlation between TPC and TAC (r=0.99) although they do not contain detectable amounts of resveratrol, they contain significant amount of rutin. Therefore, antioxidant properties might be associated with the presence of flavanols in these wines. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Electron nuclear double resonance study of photostimulated luminescence active centers in CsBr:Eu{sup 2+} medical imaging plates

    SciTech Connect

    Vrielinck, H.; Loncke, F.; Matthys, P.; Callens, F.; Tahon, J.-P.; Leblans, P.

    2011-02-01

    CsBr:Eu{sup 2+} needle image plates exhibit an electron-paramagnetic-resonance (EPR) spectrum at room temperature (RT), whose intensity is correlated with the photostimulated luminescence sensitivity of the plate. This EPR spectrum shows a strong temperature dependence: At RT it is owing to a single Eu{sup 2+} (S =7/2) center with axial symmetry, whereas at T<35 K the spectra can only be explained when two distinct centers are assumed to be present, a minority axial center and a majority center with nearly extremely rhombic symmetry. In this paper these low-temperature centers are studied with electron nuclear double resonance (ENDOR) spectroscopy, which reveals the presence of {sup 1}H nuclei close to the central Eu{sup 2+} ions in the centers. Analysis of the angular dependence of the ENDOR spectra allows to propose models for these centers, providing an explanation for the observed difference in intensity between the spectral components and for their temperature dependence.

  13. Comparison of cone beam CT scans with enhanced photostimulated phosphor plate images in the detection of root fracture of endodontically treated teeth

    PubMed Central

    Bechara, B; McMahan, C A; Noujeim, M; Faddoul, T; Moore, W S; Teixeira, F B; Geha, H

    2013-01-01

    Objectives: Two-dimensional intraoral radiography is the most common tool for diagnosing root fractures (RFs). Cone beam CT (CBCT) is widely used to depict RFs in endodontically treated teeth. Beam hardening and other artefacts caused by gutta percha may result in an incorrect diagnosis when using CBCT only. A comparison of two CBCT machines with photostimulated phosphor (PSP) plate images enhanced with the equalization tool was carried out to detect RFs in endodontically treated teeth. Methods: 66 roots were collected, decoronated and treated endodontically using the same technique with gutta percha. 33 of these roots were randomly selected and fractured; the 2 root fragments were glued together with 1 layer of methyl methacrylate and placed randomly in 8 prepared beef rib fragments. Large fields of view (FOVs) were acquired with one CBCT unit and small FOVs with the second CBCT unit. Periapical radiographs (using intraoral PSP plates) were also acquired. A contrast enhancement tool was used when evaluating the PSP plate images. Results: Small FOV images had significantly higher accuracy (area under the receiver operating characteristic curve) and sensitivity in detecting RFs than PSP plates and large FOV images. The specificity of the enhanced PSP images was higher than, although not significantly higher than, the small FOV images and was significantly higher than the large FOV images. Conclusions: CBCT small FOVs should be acquired for depicting RFs of endodontically treated teeth. Images obtained using PSP plates had the lowest rate of false-positive results and their use can save the patient a radiation dose. PMID:23625067

  14. Optoelectronic imaging using a millimeter-wave, optically controlled, photo-injected Fresnel-zone plate antenna

    NASA Astrophysics Data System (ADS)

    Gallacher, Tom F.; Robertson, Duncan A.; Smith, Graham M.

    2012-11-01

    We present results for a rapid, precise, and wide field-of-view scanning antenna for use at millimeter and submillimeter wavelengths, based on the photo-injected Fresnel-zone plate antenna (piFZPA) method. In this paper, we demonstrate the potential of this technology as a viable solution for a range of applications demanding real-time imagery or high flexibility and beam fidelity at these frequencies. We present proof-of-principle experiments at 94 GHz that incorporate a commercial display technology operating at visible wavelengths. The 100-mm-diameter piFZPA achieves 37-dBi directivity, excellent beam symmetry, beam steering in two dimensions over a ±20-deg field of view, and precise beam control and repeatability. Preliminary results of a piFZPA-based, short-range, 94-GHz, three-dimensional imaging radar are also presented.

  15. The direct measurement using an imaging plate for coincidence of radiation centre and laser position in external radiation therapy.

    PubMed

    Terunuma, Toshiyuki; Sakae, Takeji; Nohtomi, Akihiro; Tsunashima, Yoshikazu

    2003-02-21

    A new method of quality assurance has been studied to measure coincidence of the radiation centre and a patient-setup laser position on a transverse plane to the beam at the isocentre. This measurement is achieved by using an imaging plate (IP). When radiation is applied to an IP, the energy is stored as trapped electrons. The number of electrons is decreased by local laser exposure. As a result, the radiation field produced by external beam irradiation is recorded as 'positive' information and the position of the patient-setup laser is recorded as 'negative' on an IP. The advantages of this method are the direct measurement, short time and high resolution. These are required for daily and monthly quality checks. We confirmed the advantage of this method by an experiment using a proton beam.

  16. Phase contrast without phase plates and phase rings--optical solutions for improved imaging of phase structures.

    PubMed

    Piper, Timm; Piper, Jörg

    2013-10-01

    Using the optical methods described, phase specimens can be observed with a modified light microscope in enhanced clarity, purified from typical artifacts which are apparent in standard phase contrast illumination. In particular, haloing and shade-off are absent, lateral and vertical resolution are maximized and the image quality remains constant even in problematic preparations which cannot be well examined in normal phase contrast, such as specimens beyond a critical thickness or covered by obliquely situated cover slips. The background brightness and thus the range of contrast can be continuously modulated and specimens can be illuminated in concentric-peripheral, axial or paraxial light. Additional contrast effects can be achieved by spectral color separation. Normal glass or mirror lenses can be used; they do not need to be fitted with a phase plate or a phase ring. The methods described should be of general interest for all disciplines using phase microscopy.

  17. First results of KALI-30 GW with 1 MV flash X-rays generation and characterization by Imaging plate

    NASA Astrophysics Data System (ADS)

    Sharma, A.; Shaikh, A. M.; Senthil, K.; Mitra, S.; Chandra, R.; Vishnu, S.; Sandeep, S.; Roy, A.; Rakhee, M.; Sharma, V.; Danish, M. B.; Kolge, T. S.; Ranjeet, K.; Agrawal, R.; Saroj, P. C.; Tewari, S. V.; Mittal, K. C.

    2014-07-01

    The design, development and commissioning of 1 MV pulsed electron accelerator producing Flash X-Rays is described in this paper. This pulsed power system is based on bipolar MARX generator and Blumlein followed by Explosive electron emission diode assembly. The peak pulsed power is ~ 30 GW. The electron energies in the range of 400 keV to 1030 keV are produced and delivered to experimental load of Industrial diode. Electrons are emitted from a stainless steel ring at ground potential by explosive field emission and bombard the anode tungsten pin for flash X-rays generation. The relativistic electron beam has been simulated within the diode chamber and pattern shows the beam propagation. Imaging plates are used to characterize the source size and optimization has been reported.

  18. Lipid characterization of embryo zones by silica plate laser desorption ionization mass spectrometry imaging (SP-LDI-MSI).

    PubMed

    Ferreira, Mônica S; de Oliveira, Diogo N; Gonçalves, Roseli F; Catharino, Rodrigo R

    2014-01-07

    Lipid pathways play important biological roles in mammalian embryology, directing early developmental pathways to differentiation. Phospholipids and triglycerides, among others, are the main composing lipids of zona pellucida in several embryo species. Lipid analysis in embryos by mass spectrometry usually requires sample preparation and/or matrix application. This novel approach using silica plate laser desorption/ionization mass spectrometry imaging (SP-LDI-MSI) allows direct single-cell imaging and embryo region discrimination with no matrix coating. Its application is herein described for two- and eight-cell embryos. Lipid biomarkers for blastomere and intact zona pellucida are reported and corroborated by both fragmentation reactions (MS/MS) and images. Results obtained in this work are understood to be of great use for further developments on in vitro bovine fertilization. Since much of the processes can be monitored by characteristic biomarkers, it is now possible to precisely identify cell division errors during early embryo stages, as well as evaluate pre-implantation conditions.

  19. High-resolution quasi-monochromatic X-ray imaging using a Fresnel phase zone plate and a multilayer mirror.

    PubMed

    Do, A; Troussel, Ph; Baton, S D; Dervieux, V; Gontier, D; Lecherbourg, L; Loupias, B; Obst, L; Pérez, F; Renaudin, P; Reverdin, Ch; Rubbelynck, C; Stemmler, Ph; Soullié, G

    2017-01-01

    High-resolution, high-sensitivity X-ray imaging is a real challenge in laser plasma diagnostic to attain reliable data in high-energy density plasma experiments. In this context, ultra-high-intensity lasers generate hot and dense plasma but only in a small volume. An experiment has been performed at the LULI2000 laser facility to diagnose such plasma conditions from thermal spectroscopic data. To image the emission zone plasma's Al Heβ, a Fresnel-lens-based X-ray imager has been developed. It features a 846 μm-diameter Fresnel Phase Zone Plate (FPZP) and a Pd/B4C multilayer mirror (thickness d = 5.1 nm). This association can be used between 1500 eV and 2100 eV. The FPZP's efficiency was measured on a synchrotron facility (SOLEIL) and its spatial resolution in a laser facility (EQUINOX). The mirror reflectivity was measured on the synchrotron facility BESSY II. With experimental conditions, the system resolution reaches 3.8 ± 0.6 μm with an adequate efficiency in the 1800 eV-1900 eV energy range with a solid angle of 9 × 10(-6) sr. Consequently, a FPZP is an excellent optics setup for high-resolution quasi-monochromatic X-ray imaging and provides a good collection angle. Bragg-Fresnel lenses, based on the principle of FPZP and mirrors, are currently designed for an X-ray imager at the Laser MégaJoule facility.

  20. Saturation and Dynamic Range of Microchannel Plate-Based X-Ray Imagers

    SciTech Connect

    ,

    2012-05-04

    This paper describes recent advances in Monte Carlo simulations of microchannel plate (MCP)–based x-ray detectors, a continuation of ongoing work in this area. A Monte Carlo simulation model has been developed over the past several years by National Security Technologies, LLC (NSTec). The model simulates the secondary electron emission process in an MCP pore and includes the effects of gain saturation. In this work we focus on MCP gain saturation and dynamic range. We have performed modeling and experimental characterizations of L/D = 46, 10-micron diameter, MCP-based detectors. The detectors are typically operated by applying a subnanosecond voltage pulse, which gates the detector on. Agreement between the simulations and experiment is very good for a variety of voltage pulse waveforms ranging in width from 150 to 300 ps. The results indicate that such an MCP begins to show nonlinear gain around 5 × 10^4 electrons per pore and hard saturation around 105 electrons per pore. The simulations show a difference in MCP sensitivity vs voltage for high flux of photons producing large numbers of photoelectrons on a subpicosecond timescale. Simulations and experiments both indicate an MCP dynamic range of 1 to 10,000, and the dynamic range depends on how the voltage is applied.

  1. Image-based fluidic sorting system for automated Zebrafish egg sorting into multiwell plates.

    PubMed

    Graf, Siegfried F; Hötzel, Sebastian; Liebel, Urban; Stemmer, Andreas; Knapp, Helmut F

    2011-04-01

    The global demand for the reduction of animal testing has led to the emergence of Zebrafish eggs/larvae as model organisms to replace current adult animal testing in, for example, toxicity testing. Because of the egg size (diameter 1.6mm) and the relatively easy maintenance of Zebrafish farms the eggs also offer high-throughput screening (HTS). However, the current bottleneck for HTS is the cost-efficient placing of individual organisms into single wells of a multiwell plate (MWP). The system presented here is capable of storing, sorting, and placing individual organisms in a highly reproducible manner. In about 11 min a complete 96-MWP is filled, which corresponds to about 8 sec per egg. The survival rate of fertilized transgenic and wild-type eggs was comparable to the one of the control (control 6.7%, system 7.6%). Furthermore, it was also possible to place dechorionated eggs into individual wells. The results demonstrate that the cost efficient system works gentle and reliable enough to disburden scientists from the exhausting and monotonous job of placing single eggs into single wells, such that they can concentrate on the scientific aspects of their experiments and create results with a higher statistical relevance.

  2. Engineering of apodizer filters in the optical imaging using a set of phase plates

    NASA Astrophysics Data System (ADS)

    Palillero-Sandoval, Omar; Márquez-Aguilar, Pedro Antonio; Berriel-Valdos, Luis Raul

    2016-10-01

    A numerical study of the performance of a set of phase masks and apodizer filters, which are able to extend the depth of field (DOF) in the imaging system, are presented using a test object with different levels of gray. The ambiguity function is used to display which of these filters, placed in the pupil function, can increase the DOF. The intensity quasi-point spread functions (IQPSFs) show invariance in the central spot of the IQPSF when the apodizer is placed in the optical system. This approach minimizes the replicas of the object that appears in the background of the restored images produced by the numerical processing when in the pupil function these phase filters are used simultaneously. The correlation coefficient criteria and minimum squares differences were used to evaluate the quality of the restoration process.

  3. Evaluation of the sensitivity and fading characteristics of an image plate system for x-ray diagnostics

    NASA Astrophysics Data System (ADS)

    Meadowcroft, A. L.; Bentley, C. D.; Stott, E. N.

    2008-11-01

    Image plates (IPs) are a reusable recording media capable of detecting ionizing radiation, used to diagnose x-ray emission from laser-plasma experiments. Due to their superior performance characteristics in x-ray applications [C. C. Bradford, W. W. Peppler, and J. T. Dobbins III, Med. Phys. 26, 27 (1999) and J. Digit. Imaging. 12, 54 (1999)], the Fuji Biological Analysis System (BAS) IPs are fielded on x-ray diagnostics for the HELEN laser by the Plasma Physics Department at AWE. The sensitivities of the Fuji BAS IPs have been absolutely calibrated for absolute measurements of x-ray intensity in the energy range of 0-100 keV. In addition, the Fuji BAS IP fading as a function of time was investigated. We report on the characterization of three Fuji BAS IP responses to x-rays using a radioactive source, and discrete x-ray line energies generated by the Excalibur soft x-ray facility and the Defense Radiological Standards Centre filter-fluorescer hard x-ray system at AWE.

  4. Highly stable polymer coated nano-clustered silver plates: a multimodal optical contrast agent for biomedical imaging.

    PubMed

    Ray, Aniruddha; Mukundan, Ananya; Xie, Zhixing; Karamchand, Leshern; Wang, Xueding; Kopelman, Raoul

    2014-11-07

    Here, we present a new optical contrast agent based on silver nanoplate clusters embedded inside of a polymer nano matrix. Unlike nanosphere clusters, which have been well studied, nanoplate clusters have unique properties due to the different possible orientations of interaction between the individual plates, resulting in a significant broadening of the absorption spectra. These nanoclusters were immobilized inside of a polymer cladding so as to maintain their stability and optical properties under in vivo conditions. The polymer-coated silver nanoplate clusters show a lower toxicity compared to the uncoated nanoparticles. At high nanoparticle concentrations, cell death occurs mostly due to apoptosis. These nanoparticles were used for targeted fluorescence imaging in a rat glioma cell line by incorporating a fluorescent dye into the matrix, followed by conjugation of a tumor targeting an F3 peptide. We further used these nanoparticles as photoacoustic contrast agents in vivo to enhance the contrast of the vasculature structures in a rat ear model. We observed a contrast enhancement of over 90% following the nanoparticle injection. It is also shown that these NPs can serve as efficient contrast agents, with specific targeting abilities for broadband multimodal imaging that are usable for diagnostic applications and that extend into use as therapeutic agents as well.

  5. Highly stable polymer coated nano-clustered silver plates: a multimodal optical contrast agent for biomedical imaging

    NASA Astrophysics Data System (ADS)

    Ray, Aniruddha; Mukundan, Ananya; Xie, Zhixing; Karamchand, Leshern; Wang, Xueding; Kopelman, Raoul

    2014-11-01

    Here, we present a new optical contrast agent based on silver nanoplate clusters embedded inside of a polymer nano matrix. Unlike nanosphere clusters, which have been well studied, nanoplate clusters have unique properties due to the different possible orientations of interaction between the individual plates, resulting in a significant broadening of the absorption spectra. These nanoclusters were immobilized inside of a polymer cladding so as to maintain their stability and optical properties under in vivo conditions. The polymer-coated silver nanoplate clusters show a lower toxicity compared to the uncoated nanoparticles. At high nanoparticle concentrations, cell death occurs mostly due to apoptosis. These nanoparticles were used for targeted fluorescence imaging in a rat glioma cell line by incorporating a fluorescent dye into the matrix, followed by conjugation of a tumor targeting an F3 peptide. We further used these nanoparticles as photoacoustic contrast agents in vivo to enhance the contrast of the vasculature structures in a rat ear model. We observed a contrast enhancement of over 90% following the nanoparticle injection. It is also shown that these NPs can serve as efficient contrast agents, with specific targeting abilities for broadband multimodal imaging that are usable for diagnostic applications and that extend into use as therapeutic agents as well.

  6. Highly stable polymer coated nano-clustered silver plates: A multimodal optical contrast agent for biomedical imaging

    PubMed Central

    Ray, Aniruddha; Mukundan, Ananya; Xie, Zhixing; Karamchand, Leshern; Wang, Xueding; Kopelman, Raoul

    2014-01-01

    Here we present a new optical contrast agent, based on silver nanoplate clusters embedded inside a polymer nano matrix. Unlike nanosphere clusters, which have been well studied, nanoplate clusters have unique properties due to the different possible orientations of interaction between the individual plates, resulting in a significant broadening of the absorption spectra. These nanoclusters were immobilized inside a polymer cladding, so as to maintain their stability and optical properties under in vivo conditions. The polymer coated silver nanoplate clusters show a lower toxicity, compared to the uncoated nanoparticles. At high nanoparticle concentrations, cell death occurs mostly due to apoptosis. These nanoparticles were used for targeted fluorescence imaging in a rat glioma cell line by incorporating a fluorescent dye into the matrix, followed by conjugation of a tumor targeting F3 peptide. We further used these nanoparticles as photoacoustic contrast agents in vivo, to enhance the contrast of the vasculature structures in a rat ear model. We observed a contrast enhancement of over 90%, following nanoparticle injection. It is also shown that these NP’s can serve as efficient contrast agents, with specific targeting abilities, for broadband multimodal imaging, usable for diagnostic applications and extendable into use as therapeutic agents as well. PMID:25325364

  7. Image Shutters: Gated Proximity-Focused Microchannel-Plate (MCP) Wafer Tubes Versus Gated Silicon Intensified Target (SIT) Vidicons

    NASA Astrophysics Data System (ADS)

    Yates, G. J.; King, N. S. P.; Jaramillo, S. A.; Ogle, J. W.; Noel, B. W.; Thayer, N. N.

    1983-03-01

    The imaging characteristics of two fast image shutters used for recording the spatial and temporal evolution of transient optical events in the nanosecond range have been studied. Emphasis is on the comparative performances of each shutter type under similar conditions. Response data, including gating speed, gain, dynamic range, shuttering efficiency, and resolution for 18 and 25-mm-diam proximity-focused microchannel-plate (MCP) intensifiers are com-pared with similar data for a prototype electrostatically-focused 25-mm-diam gated silicon-intensified-target (SIT) vidicon currently under development for Los Alamos National Laboratory. Several key parameters critical to optical gating speed have been varied in both tube types in order to determine the optimum performance attainable from each design. These include conductive substrate material and thickness used to reduce photocathode resistivity, spacing between gating electrodes to minimize interelectrode capacitance, the use of con-ductive grids on the photocathode substrate to permit rapid propagation of the electrical gate pulse to all areas of the photocathode, and different package geometries to provide a more effective interface with external biasing and gating circuitry. For comparable spatial resolution, most 18-mm-diam MCPs require gate times > 2.5 ns while the fastest SIT has demonstrated sub-nanosecond optical gates as short as r 400 ± 50 ps for full shuttering of the 25-mm-diam input window.

  8. Dynamic mode decomposition of separated flow over a finite blunt plate: time-resolved particle image velocimetry measurements

    NASA Astrophysics Data System (ADS)

    Liu, Yingzheng; Zhang, Qingshan

    2015-07-01

    Dynamic mode decomposition (DMD) analysis was performed on a large number of realizations of the separated flow around a finite blunt plate, which were determined by using planar time-resolved particle image velocimetry (TR-PIV). Three plates with different chord-to-thickness ratios corresponding to globally different flow patterns were particularly selected for comparison: L/D = 3.0, 6.0 and 9.0. The main attention was placed on dynamic variations in the dominant events and their interactive influences on the global fluid flow in terms of the DMD analysis. Toward this end, a real-time data transfer from the high-speed camera to the arrayed disks was built to enable continuous sampling of the spatiotemporally varying flows at the frequency of 250 Hz for a long run. The spectra of the wall-normal velocity fluctuation, the energy spectra of the DMD modes, and their spatial patterns convincingly determined the energetic unsteady events, i.e., St = 0.051 (Karman vortex street), 0.109 (harmonic event of Karman vortex street) and 0.197 (leading-edge vortex) in the shortest system L/D = 3.0, St = 0.159 (Karman vortex street) and 0.242 (leading-edge vortex) in the system L/D = 6.0, and St = 0.156 (Karman vortex street) and 0.241 (leading-edge vortex) in the longest system L/D = 9.0. In the shortest system L/D = 3.0, the first DMD mode pattern demonstrated intensified entrainment of the massive fluid above and below the whole plate by the Karman vortex street. The phase-dependent variation in the low-order flow field elucidated that this motion was sustained by the consecutive mechanisms of the convective leading-edge vortices near the upper and lower trailing edges, and the large-scale vortical structures occurring immediately behind the trailing edge, whereas the leading-edge vortices were entrained and decayed into the near wake. For the system L/D = 6.0, the closely approximated energy spectra at St = 0.159 and 0.242 indicated the balanced dominance of dual unsteady

  9. Imaging at soft X-ray wavelengths with high-gain microchannel plate detector systems

    NASA Technical Reports Server (NTRS)

    Timothy, J. Gethyn

    1986-01-01

    Multianode microchannel array (MAMA) detector systems with formats of 256 x 1024 pixels and active areas of 6 x 26 mm are now under evaluation at visible, UV and soft X-ray wavelengths. Very-large-format versions of the MAMA detectors with formats of 2048 x 2048 pixels and active areas of 52 x 52 mm are under development for use in the NASA Goddard Space Telescope Imaging Spectrograph (STIS). Open-structure versions of these detectors with Cs I photocathodes can provide a high-resolution imaging capability at EUV and soft X-ray wavelengths and can deliver a maximum count rate from each array in excess of 10 to the 6th counts/s. In addition, these detector systems have the unique capability to determine the arrival time of a detected photon to an accuracy of 100 ns or better. The construction, mode of operation, and performance characteristics of the MAMA detectors are described, and the program for the development of the very-large-format detectors is outlined.

  10. A multi-plate velocity-map imaging design for high-resolution photoelectron spectroscopy.

    PubMed

    Kregel, Steven J; Thurston, Glen K; Zhou, Jia; Garand, Etienne

    2017-09-07

    A velocity map imaging (VMI) setup consisting of multiple electrodes with three adjustable voltage parameters, designed for slow electron velocity map imaging applications, is presented. The motivations for this design are discussed in terms of parameters that influence the VMI resolution and functionality. Particularly, this VMI has two tunable potentials used to adjust for optimal focus, yielding good VMI focus across a relatively large energy range. It also allows for larger interaction volumes without significant sacrifice to the resolution via a smaller electric gradient at the interaction region. All the electrodes in this VMI have the same dimensions for practicality and flexibility, allowing for relatively easy modifications to suit different experimental needs. We have coupled this VMI to a cryogenic ion trap mass spectrometer that has a flexible source design. The performance is demonstrated with the photoelectron spectra of S(-) and CS2(-). The latter has a long vibrational progression in the ground state, and the temperature dependence of the vibronic features is probed by changing the temperature of the ion trap.

  11. A multi-plate velocity-map imaging design for high-resolution photoelectron spectroscopy

    NASA Astrophysics Data System (ADS)

    Kregel, Steven J.; Thurston, Glen K.; Zhou, Jia; Garand, Etienne

    2017-09-01

    A velocity map imaging (VMI) setup consisting of multiple electrodes with three adjustable voltage parameters, designed for slow electron velocity map imaging applications, is presented. The motivations for this design are discussed in terms of parameters that influence the VMI resolution and functionality. Particularly, this VMI has two tunable potentials used to adjust for optimal focus, yielding good VMI focus across a relatively large energy range. It also allows for larger interaction volumes without significant sacrifice to the resolution via a smaller electric gradient at the interaction region. All the electrodes in this VMI have the same dimensions for practicality and flexibility, allowing for relatively easy modifications to suit different experimental needs. We have coupled this VMI to a cryogenic ion trap mass spectrometer that has a flexible source design. The performance is demonstrated with the photoelectron spectra of S- and CS2 -. The latter has a long vibrational progression in the ground state, and the temperature dependence of the vibronic features is probed by changing the temperature of the ion trap.

  12. Imaging at soft X-ray wavelengths with high-gain microchannel plate detector systems

    NASA Technical Reports Server (NTRS)

    Timothy, J. Gethyn

    1986-01-01

    Multianode microchannel array (MAMA) detector systems with formats of 256 x 1024 pixels and active areas of 6 x 26 mm are now under evaluation at visible, UV and soft X-ray wavelengths. Very-large-format versions of the MAMA detectors with formats of 2048 x 2048 pixels and active areas of 52 x 52 mm are under development for use in the NASA Goddard Space Telescope Imaging Spectrograph (STIS). Open-structure versions of these detectors with Cs I photocathodes can provide a high-resolution imaging capability at EUV and soft X-ray wavelengths and can deliver a maximum count rate from each array in excess of 10 to the 6th counts/s. In addition, these detector systems have the unique capability to determine the arrival time of a detected photon to an accuracy of 100 ns or better. The construction, mode of operation, and performance characteristics of the MAMA detectors are described, and the program for the development of the very-large-format detectors is outlined.

  13. Seismic reflection imaging of the Juan de Fuca plate from ridge to trench: new constraints on the distribution of faulting and evolution of the crust prior to subduction

    NASA Astrophysics Data System (ADS)

    Han, S.; Carbotte, S. M.; Canales, J. P.; Nedimovic, M. R.; Carton, H. D.; Gibson, J. C.

    2016-12-01

    To characterize the evolution of the Juan de Fuca (JdF) plate from ridge to trench, quantify its hydration state prior to subduction, and assess the relationship between along-strike variations in plate structure and Cascadia subduction zone processes, the JdF Ridge-to-Trench Experiment, a joint long streamer multi-channel seismic (MCS) and wide-angle ocean bottom seismometer (OBS) survey was conducted in 2012. This study provides plate-scale images and seismic velocity of the sediments, crust, and shallowest mantle along two ridge-perpendicular transects offshore Oregon and Washington and an 400 km long trench-parallel line 10-15 km seaward of the Cascadia deformation front (DF). Here we present prestack time migrated MCS images of the three transects. Within the plate interior, we observe numerous small offset faults in the sediment section beginning 50-70 km from the ridge axis with sparse fault plane reflections confined to the upper crust. As the plate bends due to sediment loading and subduction, bright fault plane reflections that extend through the crust and 6-7 km into the mantle are imaged on the Oregon Transect within 40 km from the DF; on the Washington Transect, bending faults are confined to the sediment section and upper-middle crust. The reflection image of the along-strike transect shows more abundant reflectivity south of 45°50'N coincident with reduced seismic velocity in the lower crust derived from the OBS data (Canales et al., 2016) suggesting more faulted and hydrated crust off Oregon prior to subduction. This regional difference coincides with the plate interface transition from well locked to partially creeping at Cascadia. A series of distinctive, ridgeward-dipping (20°-40°) lower crustal reflections are imaged in 6-8 Ma crust along two cross-plate transects and are interpreted as ductile shear zones formed at the JdF ridge in response to temporal variations in mantle upwelling, possibly associated with previously recognized plate

  14. X-Ray diffraction at high pressures using image plates at a synchrotron source

    NASA Astrophysics Data System (ADS)

    Brister, Keith

    1996-03-01

    Over the past few years powder diffraction from diamond anvil cells using area detectors has increased in popularity due to the high quality of the data obtainable. The data from various laboratories has yielded to Rietveld analysis to give atomic positions and to indicate structures somewhat different from those found by other diffraction methods. In addition, images can give important information about the state of stress of the sample, preferred orientation, and grain growth. Recent work using a resistively heated diamond anvil cell( W. A. Bassett, A. H. Shen, and M. Bucknum, Rev. Sci. Instrum. 64) 2340(1993) has solved the high temperature high pressure phase of portlandite( M. Kunz, K. Leinenweber, J.B. Parise, T.-C. Wu, W.A. Bassett, K. Brister, D.J. Weidner, M.T. Vaughan, Y. Wang, Journal of High Pressure Rsch., (1995), in press.) and explored the phase diagram of HgTe. Discussion will include recent heating work as well as grain growth in cerium( G. Gu, Y.K. Vohra, and K.E. Brister, Phys. Rev. B., 52) 9107 (1995) and orientation effects.

  15. Position and time resolution measurements with a microchannel plate image intensifier: A comparison of monolithic and pixelated CeBr3 scintillators

    NASA Astrophysics Data System (ADS)

    Ackermann, Ulrich; Eschbaumer, Stephan; Bergmaier, Andreas; Egger, Werner; Sperr, Peter; Greubel, Christoph; Löwe, Benjamin; Schotanus, Paul; Dollinger, Günther

    2016-07-01

    To perform Four Dimensional Age Momentum Correlation measurements in the near future, where one obtains the positron lifetime in coincidence with the three dimensional momentum of the electron annihilating with the positron, we have investigated the time and position resolution of two CeBr3 scintillators (monolithic and an array of pixels) using a Photek IPD340/Q/BI/RS microchannel plate image intensifier. The microchannel plate image intensifier has an active diameter of 40 mm and a stack of two microchannel plates in chevron configuration. The monolithic CeBr3 scintillator was cylindrically shaped with a diameter of 40 mm and a height of 5 mm. The pixelated scintillator array covered the whole active area of the microchannel plate image intensifier and the shape of each pixel was 2.5·2.5·8 mm3 with a pixel pitch of 3.3 mm. For the monolithic setup the measured mean single time resolution was 330 ps (FWHM) at a gamma energy of 511 keV. No significant dependence on the position was detected. The position resolution at the center of the monolithic scintillator was about 2.5 mm (FWHM) at a gamma energy of 662 keV. The single time resolution of the pixelated crystal setup reached 320 ps (FWHM) in the region of the center of the active area of the microchannel plate image intensifier. The position resolution was limited by the cross-section of the pixels. The gamma energy for the pixel setup measurements was 511 keV.

  16. Paper microzone plates.

    PubMed

    Carrilho, Emanuel; Phillips, Scott T; Vella, Sarah J; Martinez, Andres W; Whitesides, George M

    2009-08-01

    This paper describes 96- and 384-microzone plates fabricated in paper as alternatives to conventional multiwell plates fabricated in molded polymers. Paper-based plates are functionally related to plastic well plates, but they offer new capabilities. For example, paper-microzone plates are thin (approximately 180 microm), require small volumes of sample (5 microL per zone), and can be manufactured from inexpensive materials ($0.05 per plate). The paper-based plates are fabricated by patterning sheets of paper, using photolithography, into hydrophilic zones surrounded by hydrophobic polymeric barriers. This photolithography used an inexpensive formulation photoresist that allows rapid (approximately 15 min) prototyping of paper-based plates. These plates are compatible with conventional microplate readers for quantitative absorbance and fluorescence measurements. The limit of detection per zone loaded for fluorescence was 125 fmol for fluorescein isothiocyanate-labeled bovine serum albumin, and this level corresponds to 0.02 the quantity of analyte per well used to achieve comparable signal-to-noise in a 96-well plastic plate (using a solution of 25 nM labeled protein). The limits of detection for absorbance on paper was approximately 50 pmol per zone for both Coomassie Brilliant Blue and Amaranth dyes; these values were 0.4 that required for the plastic plate. Demonstration of quantitative colorimetric correlations using a scanner or camera to image the zones and to measure the intensity of color, makes it possible to conduct assays without a microplate reader.

  17. Determination of hydrogen diffusion coefficients in F82H by hydrogen depth profiling with a tritium imaging plate technique

    SciTech Connect

    Higaki, M.; Otsuka, T.; Hashizume, K.; Tokunaga, K.; Ezato, K.; Suzuki, S.; Enoeda, M.; Akiba, M.

    2015-03-15

    Hydrogen diffusion coefficients in a reduced activation ferritic/martensitic steel (F82H) and an oxide dispersion strengthened F82H (ODS-F82H) have been determined from depth profiles of plasma-loaded hydrogen with a tritium imaging plate technique (TIPT) in the temperature range from 298 K to 523 K. Data on hydrogen diffusion coefficients, D, in F82H, are summarized as D [m{sup 2}*s{sup -1}] =1.1*10{sup -7}exp(-16[kJ mol{sup -1}]/RT). The present data indicate almost no trapping effect on hydrogen diffusion due to an excess entry of energetic hydrogen by the plasma loading, which results in saturation of the trapping sites at the surface and even in the bulk. In the case of ODS-F82H, data of hydrogen diffusion coefficients are summarized as D [m{sup 2}*s{sup -1}] =2.2*10{sup -7}exp(-30[kJ mol{sup -1}]/RT) indicating a remarkable trapping effect on hydrogen diffusion caused by tiny oxide particles (Y{sub 2}O{sub 3}) in the bulk of F82H. Such oxide particles introduced in the bulk may play an effective role not only on enhancement of mechanical strength but also on suppression of hydrogen penetration by plasma loading.

  18. Preparation and optimization of ceramic neutron image plates based on BaFBr : Eu2+ and GdF3

    NASA Astrophysics Data System (ADS)

    Kolb, R.; Zimmermann, J.; Schlapp, M.; Hesse, S.; von Seggern, H.

    2005-09-01

    Commercially available neutron image plates (NIPs) consist of a mixture of a powdered x-ray storage phosphor and a neutron converter, both embedded in an organic binder supported on a polymer sheet. The initiation of the storage mechanism in the phosphor is caused by conversion electrons generated in the neutron converter due to neutron absorption and activation and its subsequent decay. The organic binder phase just provides mechanical stability to the NIP but reduces its efficiency through two effects: first by the absorption of low energy electrons and second by introducing an inactive volume fraction to the layer. Avoiding the organic fraction, for example by preparing a ceramic NIP without binder, could increase the efficiency and spatial resolution without a loss in mechanical stability. In the following, two processes for preparation of ceramic NIPs are reported, both delivering ceramic NIPs consisting solely of GdF3, as the neutron converter and BaFBr : Eu2+, as the storage phosphor. The correlation between the sintering parameters and volume fraction of the neutron converter is investigated with respect to high efficiency and high spatial resolution. The generally observed antidromic behaviour between these two quantities was observed in this study also.

  19. Hard x-ray spectroscopy and imaging by a reflection zone plate in the presence of astigmatism

    DOE PAGES

    Braig, Christoph; Lochel, Heike; Firsov, Alexander; ...

    2015-12-17

    Here, the feasibility of an off-axis x-ray reflection zone plate to perform wavelength-dispersive spectroscopy, on-axis point focusing, and two-dimensional imaging is demonstrated by means of one and the same diffractive optical element (DOE) at a synchrotron radiation facility. The resolving power varies between 3 × 101 and 4 × 102 in the range of 7.6 keV to 9.0 keV, with its maximum at the design energy of 8.3 keV. This result is verified using an adjustable entrance slit, by which horizontal (H) and vertical (V) focusing to 0.85 μm(H) and 1.29 μm(V) is obtained near the sagittal focal plane ofmore » the astigmatic configuration. An angular and axial scan proves an accessible field of view of at least 0.6 arcmin × 0.8 arcmin and a focal depth of ±0.86 mm. Supported by the grating efficiency of around 17.5% and a very short pulse elongation, future precision x-ray fluorescence and absorption studies of transition metals at their K-edge on an ultrashort timescale could benefit from our findings.« less

  20. Calibration of a Thomson parabola ion spectrometer and Fujifilm imaging plate detectors for protons, deuterons, and alpha particles.

    PubMed

    Freeman, C G; Fiksel, G; Stoeckl, C; Sinenian, N; Canfield, M J; Graeper, G B; Lombardo, A T; Stillman, C R; Padalino, S J; Mileham, C; Sangster, T C; Frenje, J A

    2011-07-01

    A Thomson parabola ion spectrometer has been designed for use at the Multiterawatt (MTW) laser facility at the Laboratory for Laser Energetics (LLE) at the University of Rochester. This device uses parallel electric and magnetic fields to deflect particles of a given mass-to-charge ratio onto parabolic curves on the detector plane. Once calibrated, the position of the ions on the detector plane can be used to determine the particle energy. The position dispersion of both the electric and magnetic fields of the Thomson parabola was measured using monoenergetic proton and alpha particle beams from the SUNY Geneseo 1.7 MV tandem Pelletron accelerator. The sensitivity of Fujifilm BAS-TR imaging plates, used as a detector in the Thomson parabola, was also measured as a function of the incident particle energy over the range from 0.6 MeV to 3.4 MeV for protons and deuterons and from 0.9 MeV to 5.4 MeV for alpha particles. The device was used to measure the energy spectrum of laser-produced protons at MTW.

  1. Hard x-ray spectroscopy and imaging by a reflection zone plate in the presence of astigmatism

    SciTech Connect

    Braig, Christoph; Lochel, Heike; Firsov, Alexander; Brzhezinskaya, Maria; Hafner, Aljosa; Rehanek, Jens; Wojcik, Michael; Macrander, Albert; Assoufid, Lahsen; Erko, Alexei

    2015-12-17

    Here, the feasibility of an off-axis x-ray reflection zone plate to perform wavelength-dispersive spectroscopy, on-axis point focusing, and two-dimensional imaging is demonstrated by means of one and the same diffractive optical element (DOE) at a synchrotron radiation facility. The resolving power varies between 3 × 101 and 4 × 102 in the range of 7.6 keV to 9.0 keV, with its maximum at the design energy of 8.3 keV. This result is verified using an adjustable entrance slit, by which horizontal (H) and vertical (V) focusing to 0.85 μm(H) and 1.29 μm(V) is obtained near the sagittal focal plane of the astigmatic configuration. An angular and axial scan proves an accessible field of view of at least 0.6 arcmin × 0.8 arcmin and a focal depth of ±0.86 mm. Supported by the grating efficiency of around 17.5% and a very short pulse elongation, future precision x-ray fluorescence and absorption studies of transition metals at their K-edge on an ultrashort timescale could benefit from our findings.

  2. Establishing Reliable Cu-64 Production Process: From Target Plating to Molecular Specific Tumor Micro-PET Imaging.

    PubMed

    Xie, Qinghua; Zhu, Hua; Wang, Feng; Meng, Xiangxi; Ren, Qiushi; Xia, Chuanqin; Yang, Zhi

    2017-04-17

    Copper-64 is a useful radioisotope for positron emission tomography (PET). Due to the wide range of applications, the demand of (64)Cu with low metallic impurities is increasing. Here we report a simple method for the efficient production of high specific activity (64)Cu using a cyclotron for biomedical application. We designed new equipment based on the plating of enriched (64)Ni as the target, and used automated ion exchange chromatography to purify copper-64 efficiently after irradiation and dissolution of the target in good radiochemical and chemical yield and purity. The (64)Cu radionuclide produced using 99.32% enriched (64)Ni with a density of 61.4 ± 5.0 mg/cm², reaching a total radioactivity greater than 200 mCi, with specific activity up to 5.6 GBq/μmoL. It was further incorporated into modified monoclonal antibody DOTA-rituximab to synthesize (64)Cu-DOTA-rituximab, which was used successfully for micro-PET imaging.

  3. Ionic matrices pre-spotted matrix-assisted laser desorption/ionization plates for patient maker following in course of treatment, drug titration, and MALDI mass spectrometry imaging.

    PubMed

    Bonnel, David; Franck, Julien; Mériaux, Céline; Salzet, Michel; Fournier, Isabelle

    2013-03-01

    In the current study, we compared plastic matrix-assisted laser desorption/ionization (MALDI) plates pre-spotted with different solid ionic matrices. Data reflect that after 3 months of storage, the standards were oxidized in α-cyano-4-hydroxycinnamic acid (HCCA) whether or not in HCCA/3-acetylpyridine (3APY) and HCCA/aniline, and certain peptides, such as ubiquitin, were not detected using the HCCA matrix, whereas they were detected in pre-spotted ionic matrices. Application in peptidomics of these MALDI matrices pre-spotted plates (after 3 months of storage) with ovarian cyst fluid showed less intense signals with HCCA than with solid ionic matrices. We show that these pre-spotted ionic matrices plates can be used for relative drug quantification, high mass protein detection, and MALDI mass spectrometry imaging.

  4. Seismic reflection imaging of the Juan de Fuca plate from ridge to trench: New constraints on the distribution of faulting and evolution of the crust prior to subduction

    NASA Astrophysics Data System (ADS)

    Han, Shuoshuo; Carbotte, Suzanne M.; Canales, Juan Pablo; Nedimović, Mladen R.; Carton, Hélène; Gibson, James C.; Horning, Greg W.

    2016-03-01

    We present prestack time-migrated multichannel seismic images along two cross-plate transects from the Juan de Fuca (JdF) Ridge to the Cascadia deformation front (DF) offshore Oregon and Washington from which we characterize crustal structure, distribution and extent of faults across the plate interior as the crust ages and near the DF in response to subduction bending. Within the plate interior, we observe numerous small offset faults in the sediment section beginning 50-70 km from the ridge axis with sparse fault plane reflections confined to the upper crust. Plate bending due to sediment loading and subduction initiates at ~120-150 km and ~65-80 km seaward of the DF, respectively, and is accompanied by increase in sediment fault offsets and enhancement of deeper fault plane reflectivity. Most bend faulting deformation occurs within 40 km from the DF; on the Oregon transect, bright fault plane reflections that extend through the crust and 6-7 km into the mantle are observed. If attributed to serpentinization, ~0.12-0.92 wt % water within the uppermost 6 km of the mantle is estimated. On the Washington transect, bending faults are confined to the sediment section and upper-middle crust. The regional difference in subduction bend-faulting and potential hydration of the JdF plate is inconsistent with the spatial distribution of intermediate-depth intraslab seismicity at Cascadia. A series of distinctive, ridgeward dipping (20°-40°) lower crustal reflections are imaged in ~6-8 Ma crust along both transects and are interpreted as ductile shear zones formed within the ridge's accretionary zone in response to temporal variations in mantle upwelling, possibly associated with previously recognized plate reorganizations at 8.5 Ma and 5.9 Ma.

  5. Long-term magnetic resonance imaging evaluation of bioresorbable anterior cervical plate resorption following fusion for degenerative and traumatic disk disruption.

    PubMed

    Vaccaro, Alexander R; Sahni, Deshdeepak; Pahl, Michael A; Harrop, James S; Sharan, Ashwini D; Venger, Benjamin H; Haid, Regis W; Carrino, John A; Vadera, Sumeet; Hilibrand, Alan S; Albert, Todd J

    2006-08-15

    A retrospective magnetic resonance imaging (MRI) review of a series of patients who underwent a single-level anterior cervical discectomy and fusion followed by anterior plate stabilization using an anterior cervical resorbable mesh plate and screw system. MRI evaluation of the long-term implant resorption properties of a bioresorbable anterior cervical plate and the adjacent peri-implant soft tissue environment. The use of bioresorbable anterior cervical plates for immediate cervical stabilization following an anterior cervical discectomy and fusion presents several distinct advantages over metallic instrumentation. Bioresorbable polymers may diminish, by their resorbability, implant-related complications such as loosening, migration, and failure of instrumentation, as well as stress shielding of the underlying fusion. Information on the intermediate and long-term bony and soft tissue reaction to the resorption byproducts of these biomaterials is limited. There were 9 consecutive patients who underwent single-level anterior cervical decompression and fusion using allograft cortical bone, followed by bioresorbable polylactide anterior mesh plate and screw fixation. Following institutional review board approval, 5 of the 9 patients agreed to postoperative MRI assessment of the peri-implant area. An independent radiologist then characterized implant degradation, and the presence of soft tissue inflammation and swelling during the resorption phase of the bioresorbable plate. At an average follow-up of 32 months, MRI assessment showed no evidence of soft tissue swelling or inflammation related to the resorption of a bioresorbable anterior plate in any of the 5 patients. In addition, none of the patients complained of any dysphagia or phonation difficulties. Based on MRI assessment, these devices, at more than 2-year follow-up, did not indicate any local chronic inflammation or swelling resulting from their degradation. Clinical symptoms of dysphagia or dysarthria, a

  6. Bioabsorbable bone fixation plates for X-ray imaging diagnosis by a radiopaque layer of barium sulfate and poly(lactic-co-glycolic acid).

    PubMed

    Choi, Sung Yoon; Hur, Woojune; Kim, Byeung Kyu; Shasteen, Catherine; Kim, Myung Hun; Choi, La Mee; Lee, Seung Ho; Park, Chun Gwon; Park, Min; Min, Hye Sook; Kim, Sukwha; Choi, Tae Hyun; Choy, Young Bin

    2015-04-01

    Bone fixation systems made of biodegradable polymers are radiolucent, making post-operative diagnosis with X-ray imaging a challenge. In this study, to allow X-ray visibility, we separately prepared a radiopaque layer and attached it to a bioabsorbable bone plate approved for clinical use (Inion, Finland). We employed barium sulfate as a radiopaque material due to the high X-ray attenuation coefficient of barium (2.196 cm(2) /g). The radiopaque layer was composed of a fine powder of barium sulfate bound to a biodegradable material, poly(lactic-co-glycolic acid) (PLGA), to allow layer degradation similar to the original Inion bone plate. In this study, we varied the mass ratio of barium sulfate and PLGA in the layer between 3:1 w/w and 10:1 w/w to modulate the degree and longevity of X-ray visibility. All radiopaque plates herein were visible via X-ray, both in vitro and in vivo, for up to 40 days. For all layer types, the radio-opacity decreased with time due to the swelling and degradation of PLGA, and the change in the layer shape was more apparent for layers with a higher PLGA content. The radiopaque plates released, at most, 0.5 mg of barium sulfate every 2 days in a simulated in vitro environment, which did not appear to affect the cytotoxicity. The radiopaque plates also exhibited good biocompatibility, similar to that of the Inion plate. Therefore, we concluded that the barium sulfate-based, biodegradable plate prepared in this work has the potential to be used as a fixation device with both X-ray visibility and biocompatibility.

  7. Plate motion

    SciTech Connect

    Gordon, R.G. )

    1991-01-01

    The motion of tectonic plates on the earth is characterized in a critical review of U.S. research from the period 1987-1990. Topics addressed include the NUVEL-1 global model of current plate motions, diffuse plate boundaries and the oceanic lithosphere, the relation between plate motions and distributed deformations, accelerations and the steadiness of plate motions, the distribution of current Pacific-North America motion across western North America and its margin, plate reconstructions and their uncertainties, hotspots, and plate dynamics. A comprehensive bibliography is provided. 126 refs.

  8. Guided lamb waves and L-SAFT processing technique for enhanced detection and imaging of corrosion defects in plates with small depth-to-wavelength ratio.

    PubMed

    Sicard, René; Chahbaz, Ahmad; Goyette, Jacques

    2004-10-01

    The Lamb synthetic aperture focusing technique (L-SAFT) imaging algorithm in the Fourier domain is used to produce Lamb wave imaging in plates while considering the wave dispersive properties. This artificial focusing technique produces easy-to-interpret, modified B-scan type images of Lamb wave inspection results. The high level of sensitivity of Lamb waves combined with the L-SAFT algorithm allows one to detect and to produce images of corrosion defects with small depth-to-wavelength ratio. This paper briefly presents the formulated L-SAFT algorithm used for Lamb waves and, in more details, some experimental results obtained on simulated and real corrosion pits, demonstrating the benefit of combining L-SAFT with pulse-echo Lamb wave inspection. The obtained images of the real corrosion defects showed detection of pits with a depth-to-wavelength ratio of approximately 2/11.

  9. Absolute calibration of photostimulable image plate detectors used as (0.5-20 MeV) high-energy proton detectors

    NASA Astrophysics Data System (ADS)

    Mančić, A.; Fuchs, J.; Antici, P.; Gaillard, S. A.; Audebert, P.

    2008-07-01

    In this paper, the absolute calibration of photostimulable image plates (IPs) used as proton detectors is presented. The calibration is performed in a wide range of proton energies (0.5-20MeV) by exposing simultaneously the IP and calibrated detectors (radiochromic films and solid state detector CR39) to a source of broadband laser-accelerated protons, which are spectrally resolved. The final result is a calibration curve that enables retrieving the proton number from the IP signal.

  10. High-space resolution imaging plate analysis of extreme ultraviolet (EUV) light from tin laser-produced plasmas.

    PubMed

    Musgrave, Christopher S A; Murakami, Takehiro; Ugomori, Teruyuki; Yoshida, Kensuke; Fujioka, Shinsuke; Nishimura, Hiroaki; Atarashi, Hironori; Iyoda, Tomokazu; Nagai, Keiji

    2017-03-01

    With the advent of high volume manufacturing capabilities by extreme ultraviolet lithography, constant improvements in light source design and cost-efficiency are required. Currently, light intensity and conversion efficiency (CE) measurments are obtained by charged couple devices, faraday cups etc, but also phoshpor imaging plates (IPs) (BaFBr:Eu). IPs are sensitive to light and high-energy species, which is ideal for studying extreme ultraviolet (EUV) light from laser produced plasmas (LPPs). In this work, we used IPs to observe a large angular distribution (10°-90°). We ablated a tin target by high-energy lasers (1064 nm Nd:YAG, 10(10) and 10(11) W/cm(2)) to generate the EUV light. The europium ions in the IP were trapped in a higher energy state from exposure to EUV light and high-energy species. The light intensity was angular dependent; therefore excitation of the IP depends on the angle, and so highly informative about the LPP. We obtained high-space resolution (345 μm, 0.2°) angular distribution and grazing spectrometer (5-20 nm grate) data simultaneously at different target to IP distances (103 mm and 200 mm). Two laser systems and IP types (BAS-TR and BAS-SR) were also compared. The cosine fitting values from the IP data were used to calculate the CE to be 1.6% (SD ± 0.2) at 13.5 nm 2% bandwidth. Finally, a practical assessment of IPs and a damage issue are disclosed.

  11. High-space resolution imaging plate analysis of extreme ultraviolet (EUV) light from tin laser-produced plasmas

    NASA Astrophysics Data System (ADS)

    Musgrave, Christopher S. A.; Murakami, Takehiro; Ugomori, Teruyuki; Yoshida, Kensuke; Fujioka, Shinsuke; Nishimura, Hiroaki; Atarashi, Hironori; Iyoda, Tomokazu; Nagai, Keiji

    2017-03-01

    With the advent of high volume manufacturing capabilities by extreme ultraviolet lithography, constant improvements in light source design and cost-efficiency are required. Currently, light intensity and conversion efficiency (CE) measurments are obtained by charged couple devices, faraday cups etc, but also phoshpor imaging plates (IPs) (BaFBr:Eu). IPs are sensitive to light and high-energy species, which is ideal for studying extreme ultraviolet (EUV) light from laser produced plasmas (LPPs). In this work, we used IPs to observe a large angular distribution (10°-90°). We ablated a tin target by high-energy lasers (1064 nm Nd:YAG, 1010 and 1011 W/cm2) to generate the EUV light. The europium ions in the IP were trapped in a higher energy state from exposure to EUV light and high-energy species. The light intensity was angular dependent; therefore excitation of the IP depends on the angle, and so highly informative about the LPP. We obtained high-space resolution (345 μm, 0.2°) angular distribution and grazing spectrometer (5-20 nm grate) data simultaneously at different target to IP distances (103 mm and 200 mm). Two laser systems and IP types (BAS-TR and BAS-SR) were also compared. The cosine fitting values from the IP data were used to calculate the CE to be 1.6% (SD ± 0.2) at 13.5 nm 2% bandwidth. Finally, a practical assessment of IPs and a damage issue are disclosed.

  12. Measurements of neutron distribution in neutrons-gamma-rays mixed field using imaging plate for neutron capture therapy.

    PubMed

    Tanaka, Kenichi; Endo, Satoru; Hoshi, Masaharu

    2010-01-01

    The imaging plate (IP) technique is tried to be used as a handy method to measure the spatial neutron distribution via the (157)Gd(n,gamma)(158)Gd reaction for neutron capture therapy (NCT). For this purpose, IP is set in a water phantom and irradiated in a mixed field of neutrons and gamma-rays. The Hiroshima University Radiobiological Research Accelerator is utilized for this experiment. The neutrons are moderated with 20-cm-thick D(2)O to obtain suitable neutron field for NCT. The signal for IP doped with Gd as a neutron-response enhancer is subtracted with its contribution by gamma-rays, which was estimated using IP without Gd. The gamma-ray response of Gd-doped IP to non-Gd IP is set at 1.34, the value measured for (60)Co gamma-rays, in estimating the gamma-ray contribution to Gd-doped IP signal. Then measured distribution of the (157)Gd(n,gamma)(158)Gd reaction rate agrees within 10% with the calculated value based on the method that has already been validated for its reproducibility of Au activation. However, the evaluated distribution of the (157)Gd(n,gamma)(158)Gd reaction rate is so sensitive to gamma-ray energy, e.g. the discrepancy of the (157)Gd(n,gamma)(158)Gd reaction rate between measurement and calculation becomes 30% for the photon energy change from 33keV to 1.253MeV.

  13. Structure of the Lithosphere-Asthenosphere System Beneath the Juan de Fuca Plate: Results of Body Wave Imaging Using Cascadia Initiative Data

    NASA Astrophysics Data System (ADS)

    Byrnes, J. S.; Toomey, D. R.; Hooft, E. E. E.

    2014-12-01

    The plate-scale deployment of ocean bottom seismometers (OBS) as part of the Cascadia Initiative (CI) of NSF provides a unique opportunity to study the structure and dynamics of the lithosphere-asthenosphere system beneath an entire oceanic plate, from its birth at a spreading center to its subduction beneath a continent. Here we present tomographic images of the seismic structure of oceanic upper mantle beneath the Juan de Fuca (JdF) and Gorda plates derived from body wave delay times. The results constrain structural anomalies beneath the JdF and Gorda spreading centers, the Blanco and Mendocino transform faults, near ridge hotspots such as Axial Seamount, and the upper mantle structure beneath the subducting oceanic lithosphere. We measured delay times of teleseismic P and S wave phases for the first two years of the CI. Our tomographic analysis assumes both isotropic and anisotropic starting models and accounts for finite-frequency effects and three-dimensional ray bending. Preliminary results indicate that the upper mantle structure beneath the JdF spreading center is asymmetric, with lower shear wave velocities beneath the Pacific plate (also the direction of ridge migration). On a regional scale, regions of lower seismic velocities beneath the JdF and Gorda spreading centers correlate with shallower ridge depths. Beneath the southern Gorda plate a low velocity anomaly is detected, which is absent to the north; this anomaly is bounded to the south by the Mendocino transform. Ongoing work includes analysis of the third year of CI data, which will improve resolution of structure and allow better definition of anomalies in the vicinity of the Blanco transform. In addition, we will combine ocean and continental data to obtain images of the Cascadia subduction zone.

  14. [Photostimulation plates or conventional films for bedside chest x-ray in pediatric radiology? A comparative study of quality of image and the dose delivered to patients].

    PubMed

    Maccia, C; Docou le Pointe, H; Fery-Lemonnier, E; Nadeau, X; Montagne, J P; Charpentier, E; Ariche-Cohen, M; Viens-Bitker, C

    1996-11-01

    Image quality and patient doses received during chest bedside examinations performed with conventional (film-screen combination) and photostimulable phosphorus plate systems were compared in a study carried out in 1993 in a French pediatric radiology department. Seventy one children (36 males and 35 females) aged between 9 days and 18 years (average: 43 months) were included in the study. Technical performances of all radiological equipment used were permanently checked through a quality control program. One conventional and 3 "photostimulable" films were performed for each patient included (mAs product selected for "photostimulable" system was progressively reduced down to 60% of that of conventional technique). TLD Lithium Fluoride chips were used to measure entrance surface dose during the examination. Image quality of 284 films (213 "photostimulable" + 71 conventional) was assessed by three independent radiologists. Advantages and drawbacks of both studied imaging techniques are discussed in terms of patient dose reduction and image quality.

  15. Hindlimb heating increases vascular access of large molecules to murine tibial growth plates measured by in vivo multiphoton imaging

    PubMed Central

    Efaw, Morgan L.; Williams, Rebecca M.

    2013-01-01

    Advances in understanding the molecular regulation of longitudinal growth have led to development of novel drug therapies for growth plate disorders. Despite progress, a major unmet challenge is delivering therapeutic agents to avascular-cartilage plates. Dense extracellular matrix and lack of penetrating blood vessels create a semipermeable “barrier,” which hinders molecular transport at the vascular-cartilage interface. To overcome this obstacle, we used a hindlimb heating model to manipulate bone circulation in 5-wk-old female mice (n = 22). Temperatures represented a physiological range of normal human knee joints. We used in vivo multiphoton microscopy to quantify temperature-enhanced delivery of large molecules into tibial growth plates. We tested the hypothesis that increasing hindlimb temperature from 22°C to 34°C increases vascular access of large systemic molecules, modeled using 10, 40, and 70 kDa dextrans that approximate sizes of physiological regulators. Vascular access was quantified by vessel diameter, velocity, and dextran leakage from subperichondrial plexus vessels and accumulation in growth plate cartilage. Growth plate entry of 10 kDa dextrans increased >150% at 34°C. Entry of 40 and 70 kDa dextrans increased <50%, suggesting a size-dependent temperature enhancement. Total dextran levels in the plexus increased at 34°C, but relative leakage out of vessels was not temperature dependent. Blood velocity and vessel diameter increased 118% and 31%, respectively, at 34°C. These results demonstrate that heat enhances vascular carrying capacity and bioavailability of large molecules around growth plates, suggesting that temperature could be a noninvasive strategy for modulating delivery of therapeutics to impaired growth plates of children. PMID:24371019

  16. Hindlimb heating increases vascular access of large molecules to murine tibial growth plates measured by in vivo multiphoton imaging.

    PubMed

    Serrat, Maria A; Efaw, Morgan L; Williams, Rebecca M

    2014-02-15

    Advances in understanding the molecular regulation of longitudinal growth have led to development of novel drug therapies for growth plate disorders. Despite progress, a major unmet challenge is delivering therapeutic agents to avascular-cartilage plates. Dense extracellular matrix and lack of penetrating blood vessels create a semipermeable "barrier," which hinders molecular transport at the vascular-cartilage interface. To overcome this obstacle, we used a hindlimb heating model to manipulate bone circulation in 5-wk-old female mice (n = 22). Temperatures represented a physiological range of normal human knee joints. We used in vivo multiphoton microscopy to quantify temperature-enhanced delivery of large molecules into tibial growth plates. We tested the hypothesis that increasing hindlimb temperature from 22°C to 34°C increases vascular access of large systemic molecules, modeled using 10, 40, and 70 kDa dextrans that approximate sizes of physiological regulators. Vascular access was quantified by vessel diameter, velocity, and dextran leakage from subperichondrial plexus vessels and accumulation in growth plate cartilage. Growth plate entry of 10 kDa dextrans increased >150% at 34°C. Entry of 40 and 70 kDa dextrans increased <50%, suggesting a size-dependent temperature enhancement. Total dextran levels in the plexus increased at 34°C, but relative leakage out of vessels was not temperature dependent. Blood velocity and vessel diameter increased 118% and 31%, respectively, at 34°C. These results demonstrate that heat enhances vascular carrying capacity and bioavailability of large molecules around growth plates, suggesting that temperature could be a noninvasive strategy for modulating delivery of therapeutics to impaired growth plates of children.

  17. Hyperspectral imaging for detection of non-O157 Shiga-toxin producing Escherichia coli (STEC) serogroups on spread plates of mixed cultures

    NASA Astrophysics Data System (ADS)

    Yoon, Seung Chul; Windham, William R.; Ladely, Scott; Heitschmidt, Gerald W.; Lawrence, Kurt C.; Park, Bosoon; Narang, Neelam; Cray, William C.

    2012-05-01

    We investigated the feasibility of visible and near-infrared (VNIR) hyperspectral imaging for rapid presumptive-positive screening of six representative non-O157 Shiga-toxin producing Escherichia coli (STEC) serogroups (O26, O45, O103, O111, O121, and O145) on spread plates of mixed cultures. Although the traditional culture method is still the "gold standard" for presumptive-positive pathogen screening, it is time-consuming, labor-intensive, not effective in testing large amount of food samples, and cannot completely prevent unwanted background microflora from growing together with target microorganisms on agar media. A previous study was performed using the data obtained from pure cultures individually inoculated on spot and/or spread plates in order to develop multivariate classification models differentiating each colony of the six non-O157 STEC serogroups and to optimize the models in terms of parameters. This study dealt with the validation of the trained and optimized models with a test set of new independent samples obtained from colonies on spread plates of mixed cultures. A new validation protocol appropriate to a hyperspectral imaging study for mixed cultures was developed. One imaging experiment with colonies obtained from two serial dilutions was performed. A total of six agar plates were prepared, where O45, O111 and O121 serogroups were inoculated into all six plates and each of O45, O103 and O145 serogroups was added into the mixture of the three common bacterial cultures. The number of colonies grown after 24-h incubation was 331 and the number of pixels associated with the grown colonies was 16,379. The best model found from this validation study was based on pre-processing with standard normal variate and detrending (SNVD), first derivative, spectral smoothing, and k-nearest neighbor classification (kNN, k=3) of scores in the principal component subspace spanned by 6 principal components. The independent testing results showed 95% overall

  18. Dose profile measurement using an imaging plate: Evaluation of filters using Monte Carlo simulation of 4 MV x-rays.

    PubMed

    Hashimoto, Masatoshi; Tomita, Tetsuya; Sawada, Koichi; Fujibuchi, Toshioh; Nishio, Teiji; Nakagawa, Keiichi

    2009-04-01

    Computed radiography (CR) is gradually replacing film. The application of CR for two-dimensional profiles and off-axis ratio (OAR) measurement using an imaging plate (IP) in a CR system is currently under discussion. However, a well known problem for IPs in dosimetry is that they use high atomic number (Z) materials, such as Ba, which have an energy dependency in a photon interaction. Although there are some reports that it is possible to compensate for the energy dependency with metal filters, the appropriate thicknesses of these filters and where they should be located have not been investigated. The purpose of this study is to find the most suitable filter for use with an IP as a dosimetric tool. Monte Carlo simulation (Geant4 8.1) was used to determine the filter to minimize the measurement error in OAR measurements of 4 MV x-rays. In this simulation, the material and thickness of the filter and distance between the IP and the filter were varied to determine most suitable filter conditions that gave the best fit to the MC calculated OAR in water. With regard to changing the filter material, we found that using higher Z and higher density material increased the effectiveness of the filter. Also, increasing the distance between the filter and the IP reduced the effectiveness, whereas increasing the thickness of the filter increased the effectiveness. The result of this study showed that the most appropriate filter conditions consistent with the calculated OAR in water were the ones with the IP sandwiched between two 2 mm thick lead filters at a distance of 5 mm from the IP or the IP sandwiched directly between two 1 mm lead filters. Using these filters, we measured the OAR at 10 cm depth with 100 cm source-to-surface distance and surface 10x10 cm(2) field size. The results of this measurement represented that it is possible to achieve measurements with less than within 2.0% and 2.0% in the field and with less than 1.1% and 0.6% out of the field by using 2 and 1

  19. Imaging of radioactive material and its host particle from the nuclear power plant accident in Japan by using imaging plate and electron microscopy

    NASA Astrophysics Data System (ADS)

    Adachi, Kouji; Zaizen, Yuji; Kimura, Tohru; Sakoh, Hiroshi; Igarashi, Yasuhito

    2013-04-01

    The Fukushima Daiichi Nuclear Power Plant accident in Japan on March, 2012, dispersed radioactive materials. In the Meteorological Research Institute, where locates 170 km south west from the power plant, we collected two types of filter aerosol samples and wet and dry deposition particles before and after the accident. Using these samples, we analyzed 1) radioactivity using an imaging plate (IP), which visualizes the radioactivity of samples in a two-dimensional plane with space resolution ~0.05 mm and 2) shape and compositions of particles that host radioactive materials using a scanning electron microscope (SEM) with energy-dispersive X-ray spectrometer (EDS). From the samples collected on March 15 and 21, we found radioactive spots on the filter samples using the IP, suggesting that radioactive materials, presumably Cs, were carried from the power plant. Radioactivity was also detected over the aggregates of dust particles in wet and dry deposition samples collected from March 2011. We did not find any detectable radioactive materials after the April when using the IP. We further investigated the radioactive spots using the SEM to identify the host particles of the radioactive materials and to detect radioactive materials from the EDS analysis. From the SEM analysis, we found that the particles on the filters include sulfate, mineral dust, and metals, but there were no particular particles or materials in the radioactive spots comparing to those in other area. The result suggests that the radioactive materials are hosted on the surface of other particles or inside them. We, so far, did not obtain any evidences that the radioactive materials are particulate with larger than 0.1 micro meter. Further analysis will need to identify the source of radioactive spots from individual particles using a manipulator as well as SEM and IP. Such studies will reveal where the radioactive materials exist in the environment, how they resuspend in the air, and how they could

  20. Arrays of holes fabricated by electron-beam lithography combined with image reversal process using nickel pulse reversal plating

    NASA Astrophysics Data System (ADS)

    Awad, Yousef; Lavallée, Eric; Lau, Kien Mun; Beauvais, Jacques; Drouin, Dominique; Cloutier, Melanie; Turcotte, David; Yang, Pan; Kelkar, Prasad

    2004-05-01

    A critical issue in fabricating arrays of holes is to achieve high-aspect-ratio structures. Formation of ordered arrays of nanoholes in silicon nitride was investigated by the use of ultrathin hard etch mask formed by nickel pulse reversal plating to invert the tonality of a dry e-beam resist patterned by e-beam lithography. Ni plating was carried out using a commercial plating solution based on nickel sulfamate salt without organic additives. Reactive ion etching using SF6/CH4 was found to be very effective for pattern transfer to silicon nitride. Holes array of 100 nm diam, 270 nm period, and 400 nm depth was fabricated on a 5×5 mm2 area. .

  1. Novel chemiluminescent imaging microtiter plates for high-throughput detection of multiple serum biomarkers related to Down's syndrome via soybean peroxidase as label enzyme.

    PubMed

    Zhao, Fang; Chai, Da; Lu, Jusheng; Yu, Jiachao; Liu, Songqin

    2015-08-01

    Novel chemiluminescent (CL) imaging microtiter plates with high-throughput, low-cost, and simple operation for detection of four biomarkers related to Down's syndrome screening were developed and evaluated. To enhance the sensitivity of CL immunosensing, soybean peroxidase (SBP) was used instead of horseradish peroxide (HRP) as a label enzyme. The microtiter plates were fabricated by simultaneously immobilizing four capture monoclonal antibodies, anti-inhibin-A, anti-unconjugated oestriol (anti-uE3), anti-alpha-fetoprotein (anti-AFP), and beta anti-HCG (anti-β-HCG), on nitrocellulose (NC) membrane to form immunosensing microtiter wells. Under a sandwiched immunoassay, the CL signals on each sensing site of the microtiter plates were collected by a charge-coupled device (CCD), presenting an array-based chemiluminescence imaging method for detection of four target antigens in a well at the same time. The linear response to the analyte concentration ranged from 0.1 to 40 ng/mL for inhibin-A, 0.075 to 40 ng/mL for uE3, 0.2 to 400 ng/mL for AFP, and 0.4 to 220 ng/mL for β-HCG. The proposed microtiter plates possessed high-throughput, good stability, and acceptable accuracy for detection of four antigens in clinical serum samples and demonstrated potential for practical applicability of the proposed method to Down's syndrome screening. Graphical Abstract Schematic evaluation of the microtiter plater for simultaneous detection of the four biomarkers.

  2. Establishing a Customized Guide Plate for Osteotomy in Total Knee Arthroplasty Using Lower-extremity X-ray and Knee Computed Tomography Images.

    PubMed

    Zhang, Jin; Tian, Xiao-Bin; Sun, Li; Hu, Ru-Yin; Tian, Jia-Liang; Han, Wei; Zhao, Jin-Min

    2016-02-20

    The conventional method cannot guarantee the precise osteotomies required for a perfect realignment and a better prognosis after total knee arthroplasty (TKA). This study investigated a customized guide plate for osteotomy placement in TKAs with the aid of the statistical shape model technique using weight-bearing lower-extremity X-rays and computed tomography (CT) images of the knee. From October 2014 to June 2015, 42 patients who underwent a TKA in Guizhou Provincial People's Hospital were divided into a guide plate group (GPG, 21 cases) and a traditional surgery group (TSG, 21 cases) using a random number table method. In the GPG group, a guide plate was designed and printed using preoperative three-dimensional measurements to plan and digitally simulate the operation. TSG cases were treated with the conventional method. Outcomes were obtained from the postoperative image examination and short-term follow-up. Operative time was 49.0 ± 10.5 min for GPG, and 62.0 ± 9.7 min in TSG. The coronal femoral angle, coronal tibial angle, posterior tibial slope, and the angle between the posterior condylar osteotomy surface and the surgical transepicondylar axis were 89.2 ± 1.7°, 89.0 ± 1.1°, 6.6 ± 1.4°, and 0.9 ± 0.3° in GPG, and 86.7 ± 2.9°, 87.6 ± 2.1°, 8.9 ± 2.8°, and 1.7 ± 0.8° in TSG, respectively. The Hospital for Special Surgery scores 3 months after surgery were 83.7 ± 18.4 in GPG and 71.5 ± 15.2 in TSG. Statistically significant differences were found between GPG and TSG in all measurements. A customized guide plate to create an accurate osteotomy in TKAs may be created using lower-extremity X-ray and knee CT images. This allows for shorter operative times and better postoperative alignment than the traditional surgery. Application of the digital guide plate may also result in better short-term outcomes.

  3. Establishing a Customized Guide Plate for Osteotomy in Total Knee Arthroplasty Using Lower-extremity X-ray and Knee Computed Tomography Images

    PubMed Central

    Zhang, Jin; Tian, Xiao-Bin; Sun, Li; Hu, Ru-Yin; Tian, Jia-Liang; Han, Wei; Zhao, Jin-Min

    2016-01-01

    Background: The conventional method cannot guarantee the precise osteotomies required for a perfect realignment and a better prognosis after total knee arthroplasty (TKA). This study investigated a customized guide plate for osteotomy placement in TKAs with the aid of the statistical shape model technique using weight-bearing lower-extremity X-rays and computed tomography (CT) images of the knee. Methods: From October 2014 to June 2015, 42 patients who underwent a TKA in Guizhou Provincial People's Hospital were divided into a guide plate group (GPG, 21 cases) and a traditional surgery group (TSG, 21 cases) using a random number table method. In the GPG group, a guide plate was designed and printed using preoperative three-dimensional measurements to plan and digitally simulate the operation. TSG cases were treated with the conventional method. Outcomes were obtained from the postoperative image examination and short-term follow-up. Results: Operative time was 49.0 ± 10.5 min for GPG, and 62.0 ± 9.7 min in TSG. The coronal femoral angle, coronal tibial angle, posterior tibial slope, and the angle between the posterior condylar osteotomy surface and the surgical transepicondylar axis were 89.2 ± 1.7°, 89.0 ± 1.1°, 6.6 ± 1.4°, and 0.9 ± 0.3° in GPG, and 86.7 ± 2.9°, 87.6 ± 2.1°, 8.9 ± 2.8°, and 1.7 ± 0.8° in TSG, respectively. The Hospital for Special Surgery scores 3 months after surgery were 83.7 ± 18.4 in GPG and 71.5 ± 15.2 in TSG. Statistically significant differences were found between GPG and TSG in all measurements. Conclusions: A customized guide plate to create an accurate osteotomy in TKAs may be created using lower-extremity X-ray and knee CT images. This allows for shorter operative times and better postoperative alignment than the traditional surgery. Application of the digital guide plate may also result in better short-term outcomes. PMID:26879010

  4. Imaging Variations within the South Central Chilean Fore-Arc and Subducting Nazca Plate from Receiver Functions

    NASA Astrophysics Data System (ADS)

    Bishop, B.; Beck, S. L.; Zandt, G.

    2016-12-01

    Fore-arcs represent structurally complex parts of subduction systems that contain significant along strike variations. Understanding how these variations at depth relate, or fail to relate, to surface structure and the deeper structure of subduction zones will improve our ability to model subduction processes. To contribute to this effort, we present results from 1137 P-wave Receiver Functions (RFs) calculated for P-, PP-, and PKP-phases recorded at 123 temporary and permanent seismic stations deployed in central Chile between the coastline and western edge of the Andean volcanic arc between 33°S and 38.5°S where the Nazca oceanic plate subducts beneath the South American continental plate. We have used a previously published S-wave velocity model obtained for the region from ambient noise tomography to migrate our RFs to depth through common conversion point stacking, then used the resulting stacked RFs to identify and map the laterally continuous subducted oceanic Moho arrival of the Nazca Plate and a number of features within the South American fore-arc. We have found that the subducted oceanic Moho of the Nazca Plate exhibits variations in depth that are not present in larger scale slab models. The slab's Moho geometry is relatively simple above 40 km depth, however below 40 km depth the slab exhibits noticeable strike perpendicular buckling with an approximate 50-100 km spacing between individual features. These buckling features are not easily relatable to features in the unsubducted plate and may have been imposed on the slab during the subduction process. We have also found that the South American fore-arc Moho is complicated in much of the region and is represented by a negative amplitude RF arrival up to approximately 30 km to 50 km inboard from the coast line. This suggests either that the fore-arc mantle well inboard of the coastline is significantly hydrated or that South American continental crust in this location lies directly above the subduction

  5. Development of monitoring method of spatial neutron distribution in neutrons-gamma rays mixed field using imaging plate for NCT--depression of the field.

    PubMed

    Tanaka, Kenichi; Endo, Satoru; Hoshi, Masaharu; Takada, Jun

    2011-12-01

    The degree of depression in the neutron field caused by neutron absorption in the materials of an imaging plate (IP) was investigated using MCNP-4C. Consequently, the IP doped with Gd, which reproduced the distribution of (157)Gd(n,γ)(158)Gd reaction rate in the previous study, depresses the relative distribution by about 50%. The depression for the IP in which Gd is replaced with similar amount of B atoms was estimated to be about 10%. The signal intensity for this IP is estimated to be at a similar level with that for Gd-doped IP.

  6. Millimeter wave imaging at up to 40 frames per second using an optoelectronic photo-injected Fresnel zone plate lens antenna

    NASA Astrophysics Data System (ADS)

    Robertson, Duncan A.; Gallacher, Thomas F.; Søndenâ, Rune; Macfarlane, David G.

    2016-05-01

    Optoelectronic methods are promising for rapid and highly reconfigurable beam steering across the microwave to the terahertz range. In particular, the photo-injected Fresnel zone plate antenna (piFZPA) offers high speed, wide angle, precise beam steering with good beam quality, to enable video rate millimeter wave imagery with no moving parts. We present a piFZPA demonstrator based on a commercial digital light projector (DLP) and high power laser which achieves steering rates up to 17,500 beams per second at 94 and 188 GHz. We also demonstrate radar imaging at 94 GHz at frame rates of 40 Hz (2D PPI) and 7 Hz (3D volumetric).

  7. Position-sensitive detector system OBI for High Resolution X-Ray Powder Diffraction using on-site readable image plates

    NASA Astrophysics Data System (ADS)

    Knapp, M.; Joco, V.; Baehtz, C.; Brecht, H. H.; Berghaeuser, A.; Ehrenberg, H.; von Seggern, H.; Fuess, H.

    2004-04-01

    A one-dimensional detector system has been developed using image plates. The detector is working in transmission mode or Debye-Scherrer geometry and is on-site readable which reduces the effort for calibration. It covers a wide angular range up to 110° and shows narrow reflection half-widths depending on the capillary diameter. The acquisition time is in the range of minutes and the data quality allows for reliable Rietveld refinement of complicated structures, even in multi-phase samples. The detector opens a wide field of new applications in kinetics and temperature resolved measurements.

  8. Thickness of the Descending Philippine Sea Plate Estimated from Tomographic Images beneath the Kumano Basin, along the Nankai Trough, Southwestern Japan

    NASA Astrophysics Data System (ADS)

    Kamiya, S.; Suzuki, K.; Takahashi, N.

    2015-12-01

    The Philippine Sea plate subducts northwestward beneath the Japanese islands from the south. The average thickness of the overall Philippine Sea plate has been investigated in the oceanic area using surface wave analyses [e.g. Abe and Kanamori, 1970], suggesting a thin (30-40 km thick) plate. On the other hand, several studies have indicated a thicker Philippine Sea plate based on source mechanisms and seismicity in the eastern rim of the plate [Seno, 1987; Moriyama et al., 1989]. From tomographic images, Kamiya and Kobayashi [2007] pointed out that the subducting Philippine Sea slab has thickness variation with a stepwise offset east of Izu Peninsula. The eastern (the Kanto district) and western (north of Izu Peninsula and the Tokai district) regions have respective thicknesses of 60 and 25 km. In the Kumano basin, the Japan Agency for Marine-Earth Science and Technology (JAMSTEC) developed the Dense Oceanfloor Network System for Earthquakes and Tsunami (DONET) in order to monitor seismic activity [Kaneda et al., 2009; Kawaguchi et al., 2010]. DONET ocean-bottom stations are connected with an optical fiber cable, and data are transferred in real time to our laboratory at JAMSTEC. The present study obtains three-dimensional P-wave and S-wave seismic velocity models beneath the Kumano basin by employing an travel time tomography technique. We pick arrival times of P and S waves from the waveform data recorded by the DONET system during the period from January 2011 to December 2014. In order to improve the resolution in the deeper regions than the seismic area inside of the descending slab, we also pick arrival times from the seismic events occurred outside of this district. We use these picked arrival times adding to the JMA catalogue data in seismic tomography. From the obtained tomographic images, we find high velocity anomalies corresponding to the descending Philippine Sea slab. We also find low velocity anomalies under the high velocity slab clearly. There

  9. Quantum efficiencies of imaging detectors with alkali halide photocathodes. I - Microchannel plates with separate and integral CsI photocathodes

    NASA Technical Reports Server (NTRS)

    Carruthers, George R.

    1987-01-01

    Measurements and comparisons have been made of the quantum efficiencies of microchannel plate (MCP) detectors in the far-UV (below 2000-A) wavelength range using CsI photocathodes (a) deposited on the front surfaces of microchannel plates and (b) deposited on solid substrates as opaque photocathodes with the resulting photoelectrons input to microchannel plates. The efficiences were measured in both pulse-counting and photodiode modes of operation. Typical efficiencies are about 15 percent at 1216 A for a CsI-coated MCP compared with 65 percent for an opaque CsI photocathode MCP detector. Special processing has yielded an efficiency as high as 20 percent for a CsI-coated MCP. This may possibly be further improved by optimization of the tilt angle of the MCP channels relative to the front face of the MCP and incident radiation. However, at present there still remains a factor of at least 3 quantum efficiency advantage in the separate opaque CsI photocathode configuration.

  10. Quantum efficiencies of imaging detectors with alkali halide photocathodes. I - Microchannel plates with separate and integral CsI photocathodes

    NASA Technical Reports Server (NTRS)

    Carruthers, George R.

    1987-01-01

    Measurements and comparisons have been made of the quantum efficiencies of microchannel plate (MCP) detectors in the far-UV (below 2000-A) wavelength range using CsI photocathodes (a) deposited on the front surfaces of microchannel plates and (b) deposited on solid substrates as opaque photocathodes with the resulting photoelectrons input to microchannel plates. The efficiences were measured in both pulse-counting and photodiode modes of operation. Typical efficiencies are about 15 percent at 1216 A for a CsI-coated MCP compared with 65 percent for an opaque CsI photocathode MCP detector. Special processing has yielded an efficiency as high as 20 percent for a CsI-coated MCP. This may possibly be further improved by optimization of the tilt angle of the MCP channels relative to the front face of the MCP and incident radiation. However, at present there still remains a factor of at least 3 quantum efficiency advantage in the separate opaque CsI photocathode configuration.

  11. TOF-SIMS imaging of halide/thiocyanate anions and hydrogen sulfide in mouse kidney sections using silver-deposited plates.

    PubMed

    Akahoshi, Noriyuki; Ishizaki, Itsuko; Naya, Masayuki; Maekawa, Toshihiko; Yamazoe, Shougo; Horiuchi, Tadashi; Kajimura, Mayumi; Ohashi, Yoshiharu; Suematsu, Makoto; Ishii, Isao

    2012-02-01

    In vivo imaging of reactive small molecule metabolites with high spatial resolution and specificity could give clues to understanding pathophysiology of various diseases. We herein applied time of flight-secondary ion mass spectrometry (TOF-SIMS) to newly developed silver-deposited plates that were stamped on mouse tissues, and succeeded in visualization of halide (Cl(-), Br(-), and I(-)) and pseudohalide thiocyanate (SCN(-)) anions, a class of substrates for neutrophils/eosinophil peroxidases to produce hypohalous acids (HOX/OX(-) mixture; X: (pseudo)halides), as well as hydrogen sulfide (H(2)S). Forty-micrometer frozen mouse kidney sections on cover glasses were attached to 37 °C preheated silver-deposited plates and incubated at -10 °C for 1 h. After sputter cleaning to remove surface contaminants, the plates were analyzed by TOF-SIMS to identify distribution of Br(-), AgBr(2)(-), I(-), AgI(2)(-), SCN(-), as well as S(2-) and AgS(-) as products of tissue-derived H(2)S. Br(-), AgBr(2)(-), I(-), and SCN(-) anions were mainly distributed in core regions including the inner medulla and inner stripe of the outer medulla (except for I(-)), rather than outer regions such as the cortex and outer stripe of the outer medulla. AgI(2)(-) anion was spread over the whole kidney, although its levels were relatively low. In contrast, S(2-) and AgS(-) anions were mainly present in the outer regions. To our knowledge, this is the first imaging study to reveal the distribution of (pseudo)halides and H(2)S in animal tissue sections.

  12. Multiple-Dynode-Layer Microchannel Plate

    NASA Technical Reports Server (NTRS)

    Woodgate, Bruce E.

    1990-01-01

    Improved microchannel-plate electron image amplifier made of stack of discrete microchannel-plate layers. New plates easier to manufacture because no need to etch long, narrow holes, to draw and bundle thin glass tubes, or to shear plates to give microchannels curvatures necessary for reduction of undesired emission of ions. Discrete dynode layers stacked with slight offset from layer to layer to form microchannel plate with curved channels. Provides for relatively fast recharging of microchannel dynodes, with consequent enhancement of performance.

  13. Deciphering the mechanics of an imaged fault system in the over-riding plate at the Shumagin Seismic Gap, Alaska subduction zone using MCS waveform tomography

    NASA Astrophysics Data System (ADS)

    Michaelson, C. A.; Delescluse, M.; Becel, A.; Nedimovic, M. R.; Shillington, D. J.; Louden, K. E.; Webb, S. C.

    2013-12-01

    The 2011 ALEUT program acquired 3500 km of multichannel seismic (MCS) data along a part of the western Alaska subduction zone, from the freely slipping Shumagin Seismic Gap to the locked regions in the Semidi segment and the western Kodiak asperity. The MCS profiles were acquired on the R/V Langseth using two 8-km-long streamers and span the entire locked zone on the megathrust, including the updip and downdip transitions to stable sliding. The primary goal was to characterize variations in the geometry and properties of the megathrust and the downgoing plate and relate them to downdip and along-strike changes in slip behavior and seismogenesis. The images capture the targeted megathrust reflectivity and its spatial variation. Notably, the two westernmost profiles show reflections arising from a major fault in the overriding plate within the Shumagin Seismic Gap located 75 km from the trench, which can be followed from the seafloor to the megathrust. The imaged normal fault bounds the seaward end of the Sanak forearc Cenozoic basin, formed after the Early Eocene reorganization of the Alaska subduction zone. The new reflection images also show that the seaward pair of the previously interpreted growth faults, thought to indicate deposition contemporaneous with basin subsidence, is a part of the imaged fault system. The unexpected imaging of this major fault system in the over-riding plate raises important questions: Has this fault been active during the most recent nearby megathrust earthquakes, such as the 1946 and 1948 earthquakes? Was the Sanak basin formed as a result of slip on the imaged normal fault system or is it a result of growth faulting that predates the formation of this fault? The timing and style of deformation on this fault has significant implications for both coupling on the megathrust seaward and landward of where the normal fault roots and tsunamigenesis. To complement constraints on the geometry and reflection characteristics of this structure

  14. RGB Color Calibration for Quantitative Image Analysis: The “3D Thin-Plate Spline” Warping Approach

    PubMed Central

    Menesatti, Paolo; Angelini, Claudio; Pallottino, Federico; Antonucci, Francesca; Aguzzi, Jacopo; Costa, Corrado

    2012-01-01

    In the last years the need to numerically define color by its coordinates in n-dimensional space has increased strongly. Colorimetric calibration is fundamental in food processing and other biological disciplines to quantitatively compare samples' color during workflow with many devices. Several software programmes are available to perform standardized colorimetric procedures, but they are often too imprecise for scientific purposes. In this study, we applied the Thin-Plate Spline interpolation algorithm to calibrate colours in sRGB space (the corresponding Matlab code is reported in the Appendix). This was compared with other two approaches. The first is based on a commercial calibration system (ProfileMaker) and the second on a Partial Least Square analysis. Moreover, to explore device variability and resolution two different cameras were adopted and for each sensor, three consecutive pictures were acquired under four different light conditions. According to our results, the Thin-Plate Spline approach reported a very high efficiency of calibration allowing the possibility to create a revolution in the in-field applicative context of colour quantification not only in food sciences, but also in other biological disciplines. These results are of great importance for scientific color evaluation when lighting conditions are not controlled. Moreover, it allows the use of low cost instruments while still returning scientifically sound quantitative data. PMID:22969337

  15. Peen plating

    NASA Technical Reports Server (NTRS)

    Babecki, A. J. (Inventor); Haehner, C. L.

    1973-01-01

    A process for metal plating which comprises spraying a mixture of metallic powder and small peening particles at high velocity against a surface is described. The velocity must be sufficient to impact and bond metallic powder onto the surface. In the case of metal surfaces, the process has as one of its advantages providing mechanical working (hardening) of the surface simultaneously with the metal plating.

  16. License Plate Recognition System for Indian Vehicles

    NASA Astrophysics Data System (ADS)

    Sanap, P. R.; Narote, S. P.

    2010-11-01

    We consider the task of recognition of Indian vehicle number plates (also called license plates or registration plates in other countries). A system for Indian number plate recognition must cope with wide variations in the appearance of the plates. Each state uses its own range of designs with font variations between the designs. Also, vehicle owners may place the plates inside glass covered frames or use plates made of nonstandard materials. These issues compound the complexity of automatic number plate recognition, making existing approaches inadequate. We have developed a system that incorporates a novel combination of image processing and artificial neural network technologies to successfully locate and read Indian vehicle number plates in digital images. Commercial application of the system is envisaged.

  17. Imaging the plate boundary between Greenland and North America within the Kane Basin by means of geophysical data

    NASA Astrophysics Data System (ADS)

    Ehrhardt, Axel; Schnabel, Michael; Damm, Volkmar; Piepjohn, Karsten

    2016-08-01

    The Nares Strait is a waterway separating NW Greenland and North America. The nature of the Nares Strait has been subject of discussion for decades, especially if it represents a transform fault that compensated the opening of the Baffin Bay in the Paleogene as Alfred Wegener supposed in 1912. The Kane Basin in the central part of Nares Strait provides an opportunity to cross the proposed fault. Geophysical data were acquired in 2001 and 2010, including among others multichannel and wide-angle seismic data. The eastern part of the Kane Basin is characterized by a solid platform most likely representing a continuation of the Paleoproterozoic Inglefield-Mobile-Belt (Greenland). In the western part, a sedimentary basin with northwestward tilted and eroded layers of Cretaceous age can be resolved. The transition between those two units shows the plate boundary between Greenland and North America and can be considered as a relic of the Wegener Fault.

  18. License plate detection algorithm

    NASA Astrophysics Data System (ADS)

    Broitman, Michael; Klopovsky, Yuri; Silinskis, Normunds

    2013-12-01

    A novel algorithm for vehicle license plates localization is proposed. The algorithm is based on pixel intensity transition gradient analysis. Near to 2500 natural-scene gray-level vehicle images of different backgrounds and ambient illumination was tested. The best set of algorithm's parameters produces detection rate up to 0.94. Taking into account abnormal camera location during our tests and therefore geometrical distortion and troubles from trees this result could be considered as passable. Correlation between source data, such as license Plate dimensions and texture, cameras location and others, and parameters of algorithm were also defined.

  19. Characterisation of deuterium spectra from laser driven multi-species sources by employing differentially filtered image plate detectors in Thomson spectrometers

    NASA Astrophysics Data System (ADS)

    Alejo, A.; Kar, S.; Ahmed, H.; Krygier, A. G.; Doria, D.; Clarke, R.; Fernandez, J.; Freeman, R. R.; Fuchs, J.; Green, A.; Green, J. S.; Jung, D.; Kleinschmidt, A.; Lewis, C. L. S.; Morrison, J. T.; Najmudin, Z.; Nakamura, H.; Nersisyan, G.; Norreys, P.; Notley, M.; Oliver, M.; Roth, M.; Ruiz, J. A.; Vassura, L.; Zepf, M.; Borghesi, M.

    2014-09-01

    A novel method for characterising the full spectrum of deuteron ions emitted by laser driven multi-species ion sources is discussed. The procedure is based on using differential filtering over the detector of a Thompson parabola ion spectrometer, which enables discrimination of deuterium ions from heavier ion species with the same charge-to-mass ratio (such as C6 +, O8 +, etc.). Commonly used Fuji Image plates were used as detectors in the spectrometer, whose absolute response to deuterium ions over a wide range of energies was calibrated by using slotted CR-39 nuclear track detectors. A typical deuterium ion spectrum diagnosed in a recent experimental campaign is presented, which was produced from a thin deuterated plastic foil target irradiated by a high power laser.

  20. Characterisation of deuterium spectra from laser driven multi-species sources by employing differentially filtered image plate detectors in Thomson spectrometers

    SciTech Connect

    Alejo, A.; Kar, S. Ahmed, H.; Doria, D.; Green, A.; Jung, D.; Lewis, C. L. S.; Nersisyan, G.; Krygier, A. G.; Freeman, R. R.; Clarke, R.; Green, J. S.; Notley, M.; Fernandez, J.; Fuchs, J.; Kleinschmidt, A.; Roth, M.; Morrison, J. T.; Najmudin, Z.; Nakamura, H.; and others

    2014-09-15

    A novel method for characterising the full spectrum of deuteron ions emitted by laser driven multi-species ion sources is discussed. The procedure is based on using differential filtering over the detector of a Thompson parabola ion spectrometer, which enables discrimination of deuterium ions from heavier ion species with the same charge-to-mass ratio (such as C{sup 6+}, O{sup 8+}, etc.). Commonly used Fuji Image plates were used as detectors in the spectrometer, whose absolute response to deuterium ions over a wide range of energies was calibrated by using slotted CR-39 nuclear track detectors. A typical deuterium ion spectrum diagnosed in a recent experimental campaign is presented, which was produced from a thin deuterated plastic foil target irradiated by a high power laser.

  1. Characterisation of deuterium spectra from laser driven multi-species sources by employing differentially filtered image plate detectors in Thomson spectrometers.

    PubMed

    Alejo, A; Kar, S; Ahmed, H; Krygier, A G; Doria, D; Clarke, R; Fernandez, J; Freeman, R R; Fuchs, J; Green, A; Green, J S; Jung, D; Kleinschmidt, A; Lewis, C L S; Morrison, J T; Najmudin, Z; Nakamura, H; Nersisyan, G; Norreys, P; Notley, M; Oliver, M; Roth, M; Ruiz, J A; Vassura, L; Zepf, M; Borghesi, M

    2014-09-01

    A novel method for characterising the full spectrum of deuteron ions emitted by laser driven multi-species ion sources is discussed. The procedure is based on using differential filtering over the detector of a Thompson parabola ion spectrometer, which enables discrimination of deuterium ions from heavier ion species with the same charge-to-mass ratio (such as C(6+), O(8+), etc.). Commonly used Fuji Image plates were used as detectors in the spectrometer, whose absolute response to deuterium ions over a wide range of energies was calibrated by using slotted CR-39 nuclear track detectors. A typical deuterium ion spectrum diagnosed in a recent experimental campaign is presented, which was produced from a thin deuterated plastic foil target irradiated by a high power laser.

  2. Response functions of Fuji imaging plates to monoenergetic protons in the energy range 0.6-3.2 MeV

    SciTech Connect

    Bonnet, T.; Denis-Petit, D.; Gobet, F.; Hannachi, F.; Tarisien, M.; Versteegen, M.; Aleonard, M. M.

    2013-01-15

    We have measured the responses of Fuji MS, SR, and TR imaging plates (IPs) to protons with energies ranging from 0.6 to 3.2 MeV. Monoenergetic protons were produced with the 3.5 MV AIFIRA (Applications Interdisciplinaires de Faisceaux d'Ions en Region Aquitaine) accelerator at the Centre d'Etudes Nucleaires de Bordeaux Gradignan (CENBG). The IPs were irradiated with protons backscattered off a tantalum target. We present the photo-stimulated luminescence response of the IPs together with the fading measurements for these IPs. A method is applied to allow correction of fading effects for variable proton irradiation duration. Using the IP fading corrections, a model of the IP response function to protons was developed. The model enables extrapolation of the IP response to protons up to proton energies of 10 MeV. Our work is finally compared to previous works conducted on Fuji TR IP response to protons.

  3. Simulations of Small-Pore Microchannel Plates for Fast Gated X-ray Imaging and Spectroscopy of High-Energy Density Plasmas

    SciTech Connect

    Craig A. Kruschwitz, Ming Wu, Greg Rochau

    2010-06-21

    This poster describes work done at National Security Technologies, LLC (NSTec), and Sandia National Laboratories (SNL) over the past several years on the design and characterization of microchannel plate (MCP)-based fast-gated x-ray imagers for use on the SNL Z machine. These cameras use 10-micron-pore MCPs similar to the type used for spectroscopy and imaging applications at other facilities. To aid in the understanding of MCP behavior, we have developed a Monte Carlo simulation model for prediction of MCP response. The code contains a detailed physical model of the electron cascade and amplification process of the MCP that includes energy conservation for the secondary electrons, the effects of elastic scattering of low-energy electrons from the channel wall, and gain saturation mechanisms from wall charging and space charge. Our model can simulate MCP response for both static and pulsed voltage waveforms. Excellent agreement between the Monte Carlo simulations and laboratory measurements has been achieved. Here, we apply our simulation model to 2-micron-pore MCPs, which, while readily available from a variety of vendors, are not used in imaging applications. We investigated the DC and pulsed gain characteristics of such an MCP, with particular emphasis on dynamic range, temporal response, and spatial resolution. The results are compared to the predicted and measured characteristics of 10-micron-pore MCPs.

  4. An Approach to Maximize Weld Penetration During TIG Welding of P91 Steel Plates by Utilizing Image Processing and Taguchi Orthogonal Array

    NASA Astrophysics Data System (ADS)

    Singh, Akhilesh Kumar; Debnath, Tapas; Dey, Vidyut; Rai, Ram Naresh

    2016-06-01

    P-91 is modified 9Cr-1Mo steel. Fabricated structures and components of P-91 has a lot of application in power and chemical industry owing to its excellent properties like high temperature stress corrosion resistance, less susceptibility to thermal fatigue at high operating temperatures. The weld quality and surface finish of fabricated structure of P91 is very good when welded by Tungsten Inert Gas welding (TIG). However, the process has its limitation regarding weld penetration. The success of a welding process lies in fabricating with such a combination of parameters that gives maximum weld penetration and minimum weld width. To carry out an investigation on the effect of the autogenous TIG welding parameters on weld penetration and weld width, bead-on-plate welds were carried on P91 plates of thickness 6 mm in accordance to a Taguchi L9 design. Welding current, welding speed and gas flow rate were the three control variables in the investigation. After autogenous (TIG) welding, the dimension of the weld width, weld penetration and weld area were successfully measured by an image analysis technique developed for the study. The maximum error for the measured dimensions of the weld width, penetration and area with the developed image analysis technique was only 2 % compared to the measurements of Leica-Q-Win-V3 software installed in optical microscope. The measurements with the developed software, unlike the measurements under a microscope, required least human intervention. An Analysis of Variance (ANOVA) confirms the significance of the selected parameters. Thereafter, Taguchi's method was successfully used to trade-off between maximum penetration and minimum weld width while keeping the weld area at a minimum.

  5. An Approach to Maximize Weld Penetration During TIG Welding of P91 Steel Plates by Utilizing Image Processing and Taguchi Orthogonal Array

    NASA Astrophysics Data System (ADS)

    Singh, Akhilesh Kumar; Debnath, Tapas; Dey, Vidyut; Rai, Ram Naresh

    2017-10-01

    P-91 is modified 9Cr-1Mo steel. Fabricated structures and components of P-91 has a lot of application in power and chemical industry owing to its excellent properties like high temperature stress corrosion resistance, less susceptibility to thermal fatigue at high operating temperatures. The weld quality and surface finish of fabricated structure of P91 is very good when welded by Tungsten Inert Gas welding (TIG). However, the process has its limitation regarding weld penetration. The success of a welding process lies in fabricating with such a combination of parameters that gives maximum weld penetration and minimum weld width. To carry out an investigation on the effect of the autogenous TIG welding parameters on weld penetration and weld width, bead-on-plate welds were carried on P91 plates of thickness 6 mm in accordance to a Taguchi L9 design. Welding current, welding speed and gas flow rate were the three control variables in the investigation. After autogenous (TIG) welding, the dimension of the weld width, weld penetration and weld area were successfully measured by an image analysis technique developed for the study. The maximum error for the measured dimensions of the weld width, penetration and area with the developed image analysis technique was only 2 % compared to the measurements of Leica-Q-Win-V3 software installed in optical microscope. The measurements with the developed software, unlike the measurements under a microscope, required least human intervention. An Analysis of Variance (ANOVA) confirms the significance of the selected parameters. Thereafter, Taguchi's method was successfully used to trade-off between maximum penetration and minimum weld width while keeping the weld area at a minimum.

  6. Generation of narrowband elastic waves with a fiber laser and its application to the imaging of defects in a plate.

    PubMed

    Hayashi, Takahiro; Ishihara, Ken

    2017-01-26

    Pulsed laser equipment can be used to generate elastic waves through the instantaneous reaction of thermal expansion or ablation of the material; however, we cannot control the waveform generated by the laser in the same manner that we can when piezoelectric transducers are used as exciters. This study investigates the generation of narrowband tone-burst waves using a fiber laser of the type that is widely used in laser beam machining. Fiber lasers can emit laser pulses with a high repetition rate on the order of MHz, and the laser pulses can be modulated to a burst train by external signals. As a consequence of the burst laser emission, a narrowband tone-burst elastic wave is generated. We experimentally confirmed that the elastic waves agreed well with the modulation signals in time domain waveforms and their frequency spectra, and that waveforms can be controlled by the generation technique. We also apply the generation technique to defect imaging with a scanning laser source. In the experiments, with small laser emission energy, we were not able to obtain defect images from the signal amplitude due to low signal-to-noise ratio, whereas using frequency spectrum peaks of the tone-burst signals gave clear defect images, which indicates that the signal-to-noise ratio is improved in the frequency domain by using this technique for the generation of narrowband elastic waves. Moreover, even for defect imaging at a single receiving point, defect images were enhanced by taking an average of distributions of frequency spectrum peaks at different frequencies.

  7. Rapid prototyping of Fresnel zone plates via direct Ga(+) ion beam lithography for high-resolution X-ray imaging.

    PubMed

    Keskinbora, Kahraman; Grévent, Corinne; Eigenthaler, Ulrike; Weigand, Markus; Schütz, Gisela

    2013-11-26

    A significant challenge to the wide utilization of X-ray microscopy lies in the difficulty in fabricating adequate high-resolution optics. To date, electron beam lithography has been the dominant technique for the fabrication of diffractive focusing optics called Fresnel zone plates (FZP), even though this preparation method is usually very complicated and is composed of many fabrication steps. In this work, we demonstrate an alternative method that allows the direct, simple, and fast fabrication of FZPs using focused Ga(+) beam lithography practically, in a single step. This method enabled us to prepare a high-resolution FZP in less than 13 min. The performance of the FZP was evaluated in a scanning transmission soft X-ray microscope where nanostructures as small as sub-29 nm in width were clearly resolved, with an ultimate cutoff resolution of 24.25 nm, demonstrating the highest first-order resolution for any FZP fabricated by the ion beam lithography technique. This rapid and simple fabrication scheme illustrates the capabilities and the potential of direct ion beam lithography (IBL) and is expected to increase the accessibility of high-resolution optics to a wider community of researchers working on soft X-ray and extreme ultraviolet microscopy using synchrotron radiation and advanced laboratory sources.

  8. Image shutters: Gated proximity-focused Microchannel Plate (MCP) wafer tubes versus gated Silicon Intensified Target (SIT) vidicons

    NASA Astrophysics Data System (ADS)

    Yates, G. J.; King, N. S. P.; Jaramillo, S. A.; Ogle, J. W.; Noel, B. W.; Thayer, N. N.

    Response data, including gating speed, gain, dynamic range, shuttering efficiency, and resolution for 18- and 25-mm-diam proximity-focused microchannel-plate (MCP) intensifiers are compared with similar data for a prototype electrostatically-focused 25-mm-diam gated silicon-intensified-target (SIT) vidicon. Conductive substrate material and thickness used to reduce photocathode resistivity, spacing between gating electrodes to minimize inter-electrode capacitance, the use of conductive grids on the photocathode substrate to permit rapid propagation of the electrical gate pulse to all areas of the photocathode, and different package geometries to provide a more effective interface with external biasing and gating circuitry were varied in both tube types to determine optimal performance from each design. For comparable spatial resolution, most 18-mm-diam MCPs require gate times 2.5 ns while the fastest SIT has demonstrated sub-nanosecond optical gates as short as approximately 400 + or - 50 ps for full shuttering of the 25-mm-diam input window.

  9. Comparison of implosion core metrics: A 10 ps dilation X-ray imager vs a 100 ps gated microchannel plate.

    PubMed

    Nagel, S R; Benedetti, L R; Bradley, D K; Hilsabeck, T J; Izumi, N; Khan, S; Kyrala, G A; Ma, T; Pak, A

    2016-11-01

    The dilation x-ray imager (DIXI) [T. J. Hilsabeck et al., Rev. Sci. Instrum. 81, 10E317 (2010); S. R. Nagel et al., ibid. 83, 10E116 (2012); S. R. Nagel et al., ibid. 85, 11E504 (2014)] is a high-speed x-ray framing camera that uses the pulse-dilation technique to achieve a temporal resolution of less than 10 ps. This is a 10 × improvement over conventional framing cameras currently employed on the National Ignition Facility (NIF) (100 ps resolution), and otherwise only achievable with 1D streaked imaging. A side effect of the dramatically reduced gate width is the comparatively lower detected signal level. Therefore we implement a Poisson noise reduction with non-local principal component analysis method [J. Salmon et al., J. Math. Imaging Vision 48, 279294 (2014)] to improve the robustness of the DIXI data analysis. Here we present results on ignition-relevant experiments at the NIF using DIXI. In particular we focus on establishing that/when DIXI gives reliable shape metrics (P0, P2, and P4 Legendre modes, and their temporal evolution/swings).

  10. Comparison of implosion core metrics: A 10 ps dilation X-ray imager vs a 100 ps gated microchannel plate

    NASA Astrophysics Data System (ADS)

    Nagel, S. R.; Benedetti, L. R.; Bradley, D. K.; Hilsabeck, T. J.; Izumi, N.; Khan, S.; Kyrala, G. A.; Ma, T.; Pak, A.

    2016-11-01

    The dilation x-ray imager (DIXI) [T. J. Hilsabeck et al., Rev. Sci. Instrum. 81, 10E317 (2010); S. R. Nagel et al., ibid. 83, 10E116 (2012); S. R. Nagel et al., ibid. 85, 11E504 (2014)] is a high-speed x-ray framing camera that uses the pulse-dilation technique to achieve a temporal resolution of less than 10 ps. This is a 10 × improvement over conventional framing cameras currently employed on the National Ignition Facility (NIF) (100 ps resolution), and otherwise only achievable with 1D streaked imaging. A side effect of the dramatically reduced gate width is the comparatively lower detected signal level. Therefore we implement a Poisson noise reduction with non-local principal component analysis method [J. Salmon et al., J. Math. Imaging Vision 48, 279294 (2014)] to improve the robustness of the DIXI data analysis. Here we present results on ignition-relevant experiments at the NIF using DIXI. In particular we focus on establishing that/when DIXI gives reliable shape metrics (P0, P2, and P4 Legendre modes, and their temporal evolution/swings).

  11. Neutron crystallography: opportunities, challenges, and limitations.

    PubMed

    Blakeley, Matthew P; Langan, Paul; Niimura, Nobuo; Podjarny, Alberto

    2008-10-01

    Neutron crystallography has had an important, but relatively small role in structural biology over the years. In this review of recently determined neutron structures, a theme emerges of a field currently expanding beyond its traditional boundaries, to address larger and more complex problems, with smaller samples and shorter data collection times, and employing more sophisticated structure determination and refinement methods. The origin of this transformation can be found in a number of advances including first, the development of neutron image-plates and quasi-Laue methods at nuclear reactor neutron sources and the development of time-of-flight Laue methods and electronic detectors at spallation neutron sources; second, new facilities and methods for sample perdeuteration and crystallization; third, new approaches and computational tools for structure determination.

  12. Wide-angle velocity modeling and receiver functions imaging a lithospheric shear tear in the southeast Caribbean-South America plate boundary

    NASA Astrophysics Data System (ADS)

    Clark, S. A.; Levander, A.; Zelt, C. A.; Niu, F.; Sobiesiak, M.

    2007-05-01

    Two models for slab detachment have been proposed for the lithospheric structure of the northern South America plate boundary with the southeast Caribbean, where westward subduction of oceanic South America transitions to east-west transform between continental South America and the Caribbean plate. In the tensile tear model, oblique convergence causes northwest-dipping subduction, and tension on the subducting slab results in detachment orthogonal to the motion vectors. Conversely, the shear tear model predicts detachment parallel to the motion vectors along a vertical plane, with shear stress focused on the edge of the propagating transform boundary. We present new active-source onshore-offshore wide-angle tomography, integrated with new passive-source receiver function analysis, from profile 64W of the BOLIVAR (Broadband Ocean-Land Investigation of Venezuela and the Antilles arc Region) project. Profile 64W is a 460 km-long, north-south, onshore-offshore reflection/refraction/teleseismic transect located approximately at 64 deg W longitude that extends from the southeastern Caribbean across the Serrania del Interior and into the Maturin basin. The various datasets image deep crustal and upper mantle structure across the entire diffuse plate boundary zone. The active-source components of profile 64W include 33 OBSs and 344 land seismic stations which recorded 7500 offshore airgun shots and 2 chemical explosive land shots. Receiver functions along 64W were picked from hundreds of events at 18 temporary and permanent broadband stations. Close agreement exists between the wide-angle inversion of first arrivals, PmP, and Pn, and receiver function analysis for the Moho conversion, indicating that the Moho deepens northward from 35 km beneath the Guiana shield craton (from receiver functions only) to 45 km beneath the Serrania del Interior; to the north, Moho abruptly shoals to a depth of 25 km. We interpret this step change in Moho depth to be the lower crustal plate

  13. Correlations of onshore/offshore structure from a combined AVHRR/Geosat altimeter image of the Antarctic Plate

    SciTech Connect

    Dalziel, I.W.D.; Royer, J.Y.; Lawver, L.A. ); Sandwell, D.T. )

    1990-06-01

    Data collected by the Advanced Very High Resolution Radiometer (AVHRR) aboard Nimbus-X and the satellite altimeter aboard Geosat have provided an extraordinary view of the Antarctic continent and the surrounding seafloor. To examine the relationship between onshore and offshore structure, the authors have merged an AVHRR mosaic image produced by the British National Remote Sensing Centre with a geoid image derived from two years of Geosat altimetry. They averaged 4-4 repeat cycles of Geosat data to improve the accuracy, resolution, and coverage of the marine geoid, especially in areas usually obscured by year-round ice. In addition to constructing the geoid image, the Geosat data were combined with available shipboard bathymetric data and magnetic anomaly identifications to construct a tectonic element chart of the Southern Ocean. The major tectonic elements include several large age-offset fracture zones that place tight constraints on the breakup of Gondwana. In many cases, onshore extensions of these major fracture zones correlate with prominent continental structures. For example, the Tasman FZ extends from the western edge of Tasmania for 2,500 km across the southern Indian Ocean and terminates along the eastern edge of George V Basin. Onshore, this prominent lineation continues along the edge of the Trans-Antarctic Mountains in Victoria Land, Antarctica. Similarly, the Udintsev FZ extends from the northern edge of the Chatham Rise for 4-500 km across the South Pacific to a point north of Thurston I., where it fades out. The onshore extension of the Udintsev FZ may mark a major tectonic and physiographic boundary between the Weddellia and Marie Byrd Land crustal blocks of West Antarctica. Other prominent onshore/offshore correlations include the continuation of the Queen Fabiola Mountains as the Gunnerus Ridge and the continuation of the Lambert-Amery aulacogen seaward onto the continental margin.

  14. Using aftershocks to Image the Subducting Pacific Plate in a Region of Deep Slow Slip, Hikurangi Margin, New Zealand

    NASA Astrophysics Data System (ADS)

    Jacobs, K. M.; Hirschberg, H.; Louie, J. N.; Savage, M. K.; Bannister, S. C.

    2014-12-01

    interface. These results are helping to build 3-D information about the plate interface. We hope that this will help us to understand future hazards posed by subduction thrust earthquakes in this region, and the feeding system for deep slow-slip earthquakes.

  15. Individual Trabeculae Segmentation (ITS)–Based Morphological Analysis of High-Resolution Peripheral Quantitative Computed Tomography Images Detects Abnormal Trabecular Plate and Rod Microarchitecture in Premenopausal Women With Idiopathic Osteoporosis

    PubMed Central

    Liu, X Sherry; Cohen, Adi; Shane, Elizabeth; Stein, Emily; Rogers, Halley; Kokolus, Shannon L; Yin, Perry T; McMahon, Donald J; Lappe, Joan M; Recker, Robert R; Guo, X Edward

    2010-01-01

    Idiopathic osteoporosis (IOP) in premenopausal women is a poorly understood entity in which otherwise healthy women have low-trauma fracture or very low bone mineral density (BMD). In this study, we applied individual trabeculae segmentation (ITS)–based morphological analysis to high-resolution peripheral quantitative computed tomography (HR-pQCT) images of the distal radius and distal tibia to gain greater insight into skeletal microarchitecture in premenopausal women with IOP. HR-pQCT scans were performed for 26 normal control individuals and 31 women with IOP. A cubic subvolume was extracted from the trabecular bone compartment and subjected to ITS-based analysis. Three Young's moduli and three shear moduli were calculated by micro–finite element (µFE) analysis. ITS-based morphological analysis of HR-pQCT images detected significantly decreased trabecular plate and rod bone volume fraction and number, decreased axial bone volume fraction in the longitudinal axis, increased rod length, and decreased rod-to-rod, plate-to-rod, and plate-to-plate junction densities at the distal radius and distal tibia in women with IOP. However, trabecular plate and rod thickness did not differ. A more rod-like trabecular microstructure was found in the distal radius, but not in the distal tibia. Most ITS measurements contributed significantly to the elastic moduli of trabecular bone independent of bone volume fraction (BV/TV). At a fixed BV/TV, plate-like trabeculae contributed positively to the mechanical properties of trabecular bone. The results suggest that ITS-based morphological analysis of HR-pQCT images is a sensitive and promising clinical tool for the investigation of trabecular bone microstructure in human studies of osteoporosis. © 2010 American Society for Bone and Mineral Research. PMID:20200967

  16. Plate electronics

    NASA Astrophysics Data System (ADS)

    Carlowicz, Michael

    Using a Cray T3D supercomputer and a simple assumption about the physical character of Earth's mantle, a pair of researchers from the University of California at Berkeley have built a computer model that may help explain why the planet's tectonic plates look the way they do.In creating a three-dimensional numerical simulation of convection in the Earth's interior, UC researchers Hans-Peter Bunge and Mark Richards simplified their model to account for just one major physical effect: that the viscosity of the mantle increases with depth. Reviewing some recent—but not yet widely accepted—seismic data, Bunge and Richards assumed for the sake of the model that the viscosity of the mantle increases by a factor of 30 from the lithosphere to the core-mantle boundary. Relying on that assumption, the pair ran the model for nearly three weeks on a supercomputer at Los Alamos National Laboratory and found that the simulation produced an effect similar to what we see on the surface of Earth. The model produced a surface paralleling the actual width of plates and the geometry of the plate boundaries.

  17. Devices, systems, and methods for imaging

    DOEpatents

    Appleby, David; Fraser, Iain; Watson, Scott

    2008-04-15

    Certain exemplary embodiments comprise a system, which can comprise an imaging plate. The imaging plate can be exposable by an x-ray source. The imaging plate can be configured to be used in digital radiographic imaging. The imaging plate can comprise a phosphor-based image storage device configured to convert an image stored therein into light.

  18. Devices, systems, and methods for imaging

    DOEpatents

    Appleby, David; Fraser, Iain; Watson, Scott

    2008-04-15

    Certain exemplary embodiments comprise a system, which can comprise an imaging plate. The imaging plate can be exposable by an x-ray source. The imaging plate can be configured to be used in digital radiographic imaging. The imaging plate can comprise a phosphor-based image storage device configured to convert an image stored therein into light.

  19. FIRST RESULTS FROM VERY LARGE TELESCOPE NACO APODIZING PHASE PLATE: 4 {mu}m IMAGES OF THE EXOPLANET {beta} PICTORIS b

    SciTech Connect

    Quanz, Sascha P.; Meyer, Michael R.; Kenworthy, Matthew A.; Girard, Julien H. V.; Kasper, Markus; Lagrange, Anne-Marie; Bonnefoy, Mickael; Chauvin, Gael; Apai, Daniel; Boccaletti, Anthony; Hinz, Philip M.; Lenzen, Rainer

    2010-10-10

    Direct imaging of exoplanets requires both high contrast and high spatial resolution. Here, we present the first scientific results obtained with the newly commissioned apodizing phase plate coronagraph (APP) on VLT/NACO. We detected the exoplanet {beta} Pictoris b in the narrowband filter centered at 4.05 {mu}m (NB4.05). The position angle (209.{sup 0}13 {+-} 2.{sup 0}12) and the projected separation to its host star (0.''354 {+-} 0.''012, i.e., 6.8 {+-} 0.2 AU at a distance of 19.3 pc) are in good agreement with the recently presented data from Lagrange et al. Comparing the observed NB4.05 magnitude of 11.20 {+-} 0.23 mag to theoretical atmospheric models, we find a best fit with a 7-10 M {sub Jupiter} object for an age of 12 Myr, again in agreement with previous estimates. Combining our results with published L' photometry, we can compare the planet's [L' - NB4.05] color to that of cool field dwarfs of higher surface gravity suggesting an effective temperature of {approx}1700 K. The best-fit theoretical model predicts an effective temperature of {approx}1470 K, but this difference is not significant given our photometric uncertainties. Our results demonstrate the potential of NACO/APP for future planet searches and provide independent confirmation as well as complementary data for {beta} Pic b.

  20. Response functions of Fuji imaging plates to monoenergetic protons in the energy range 0.6-3.2 MeV.

    PubMed

    Bonnet, T; Comet, M; Denis-Petit, D; Gobet, F; Hannachi, F; Tarisien, M; Versteegen, M; Aleonard, M M

    2013-01-01

    We have measured the responses of Fuji MS, SR, and TR imaging plates (IPs) to protons with energies ranging from 0.6 to 3.2 MeV. Monoenergetic protons were produced with the 3.5 MV AIFIRA (Applications Interdisciplinaires de Faisceaux d'Ions en Région Aquitaine) accelerator at the Centre d'Etudes Nucléaires de Bordeaux Gradignan (CENBG). The IPs were irradiated with protons backscattered off a tantalum target. We present the photo-stimulated luminescence response of the IPs together with the fading measurements for these IPs. A method is applied to allow correction of fading effects for variable proton irradiation duration. Using the IP fading corrections, a model of the IP response function to protons was developed. The model enables extrapolation of the IP response to protons up to proton energies of 10 MeV. Our work is finally compared to previous works conducted on Fuji TR IP response to protons.

  1. Validation of modelled imaging plates sensitivity to 1-100 keV x-rays and spatial resolution characterisation for diagnostics for the "PETawatt Aquitaine Laser".

    PubMed

    Boutoux, G; Batani, D; Burgy, F; Ducret, J-E; Forestier-Colleoni, P; Hulin, S; Rabhi, N; Duval, A; Lecherbourg, L; Reverdin, C; Jakubowska, K; Szabo, C I; Bastiani-Ceccotti, S; Consoli, F; Curcio, A; De Angelis, R; Ingenito, F; Baggio, J; Raffestin, D

    2016-04-01

    Thanks to their high dynamic range and ability to withstand electromagnetic pulse, imaging plates (IPs) are commonly used as passive detectors in laser-plasma experiments. In the framework of the development of the diagnostics for the Petawatt Aquitaine Laser facility, we present an absolute calibration and spatial resolution study of five different available types of IP (namely, MS-SR-TR-MP-ND) performed by using laser-induced K-shell X-rays emitted by a solid silver target irradiated by the laser ECLIPSE at CEntre Lasers Intenses et Applications. In addition, IP sensitivity measurements were performed with a 160 kV X-ray generator at CEA DAM DIF, where the absolute response of IP SR and TR has been calibrated to X-rays in the energy range 8-75 keV with uncertainties of about 15%. Finally, the response functions have been modeled in Monte Carlo GEANT4 simulations in order to reproduce experimental data. Simulations enable extrapolation of the IP response functions to photon energies from 1 keV to 1 GeV, of interest, e.g., for laser-driven radiography.

  2. Qualitative and quantitative high performance thin layer chromatography analysis of Calendula officinalis using high resolution plate imaging and artificial neural network data modelling.

    PubMed

    Agatonovic-Kustrin, S; Loescher, Christine M

    2013-10-10

    Calendula officinalis, commonly known Marigold, has been traditionally used for its anti-inflammatory effects. The aim of this study was to investigate the capacity of an artificial neural network (ANN) to analyse thin layer chromatography (TLC) chromatograms as fingerprint patterns for quantitative estimation of chlorogenic acid, caffeic acid and rutin in Calendula plant extracts. By applying samples with different weight ratios of marker compounds to the system, a database of chromatograms was constructed. A hundred and one signal intensities in each of the HPTLC chromatograms were correlated to the amounts of applied chlorogenic acid, caffeic acid, and rutin using an ANN. The developed ANN correlation was used to quantify the amounts of 3 marker compounds in calendula plant extracts. The minimum quantifiable level (MQL) of 610, 190 and 940 ng and the limit of detection (LD) of 183, 57 and 282 ng were established for chlorogenic, caffeic acid and rutin, respectively. A novel method for quality control of herbal products, based on HPTLC separation, high resolution digital plate imaging and ANN data analysis has been developed. The proposed method can be adopted for routine evaluation of the phytochemical variability in calendula extracts. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Validation of modelled imaging plates sensitivity to 1-100 keV x-rays and spatial resolution characterisation for diagnostics for the "PETawatt Aquitaine Laser"

    NASA Astrophysics Data System (ADS)

    Boutoux, G.; Batani, D.; Burgy, F.; Ducret, J.-E.; Forestier-Colleoni, P.; Hulin, S.; Rabhi, N.; Duval, A.; Lecherbourg, L.; Reverdin, C.; Jakubowska, K.; Szabo, C. I.; Bastiani-Ceccotti, S.; Consoli, F.; Curcio, A.; De Angelis, R.; Ingenito, F.; Baggio, J.; Raffestin, D.

    2016-04-01

    Thanks to their high dynamic range and ability to withstand electromagnetic pulse, imaging plates (IPs) are commonly used as passive detectors in laser-plasma experiments. In the framework of the development of the diagnostics for the Petawatt Aquitaine Laser facility, we present an absolute calibration and spatial resolution study of five different available types of IP (namely, MS-SR-TR-MP-ND) performed by using laser-induced K-shell X-rays emitted by a solid silver target irradiated by the laser ECLIPSE at CEntre Lasers Intenses et Applications. In addition, IP sensitivity measurements were performed with a 160 kV X-ray generator at CEA DAM DIF, where the absolute response of IP SR and TR has been calibrated to X-rays in the energy range 8-75 keV with uncertainties of about 15%. Finally, the response functions have been modeled in Monte Carlo GEANT4 simulations in order to reproduce experimental data. Simulations enable extrapolation of the IP response functions to photon energies from 1 keV to 1 GeV, of interest, e.g., for laser-driven radiography.

  4. Tomography of the subducting Cocos plate in central Mexico using data from the installation of a prototype wireless seismic network: Images of a truncated slab

    NASA Astrophysics Data System (ADS)

    Husker, Allen Leroy, Jr.

    WiLSoN during the MASE experiment. The MASE data is used to perform a 2D P-wave tomography of the subducting Cocos plate. A seismicity study by Pardo and Suarez (1995) mapped a flat Cocos slab under the North America plate to 190 km inland. Our tomography shows the slab subduction continues from 250 km inland at a much steeper angle of 75°. The slab stops somewhere between 450 km and 550 km depth under the northern Trans-Mexican Volcanic Belt. The Farallon plate, from which the Cocos plate presumably broke, is not seen. P-wave travel times are also inverted for a 2D temperature model of the Cocos slab under Mexico. The temperature model from Davies and Stevenson (1992) is found to have unrealistic values in the case of a thin slab, so the diffusion equation is solved with their initial conditions to correct their solution to remove this limitation. The dipping portion of the slab begins 230 km inland, dip at an angle of 74 degrees from the surface, extend to 500 km depth, and have a thickness of 40 km. The model is extended to 21/2D by assuming the slab is infinite along its width. The strike of the slab is then solved for with the full 3D rays found from ray tracing through the iasp91 model. The strike of the dipping slab is found to be 108° clockwise from north, very similar to the strike of the TMVB. A model of the tectonic history is presented that combines those proposed by Ferrari (2004) and Gorbatov and Fukao (2005). At 25 Ma the volcanic arc moved inland marking the beginning of flat-slab subduction. At the same time a tear between the Cocos and Farallon initiated. The torsion from the tear squeezed the Cocos plate causing a flat-slab geometry. At 12.5 Ma another tear propagated along the flat Cocos slab removing the torsion causing uplift. The removal of the uplift caused the upper portion of the Cocos slab to sink and start rolling back until it reached the position where it is imaged in this study. The lack of a Wadati-Benioff zone is due to no deeper

  5. Examination of Global Seismic Tomography Images and Sea-Surface Magnetic Field Anomaly Profiles in the West Philippine Basin for the Large Clockwise Rotation of the Philippine Sea Plate during the Last 55 Million Years

    NASA Astrophysics Data System (ADS)

    Choe, H.; Lee, S. M.

    2014-12-01

    The Philippine Sea Plate is thought to have undergone a 90° clockwise rotation during the last 55 million years. However, evidences for such an argument are rather circumstantial. For instance, paleomagnetic measurements for the large rotation are derived largely from Halmahera, Indonesia which is quite close to the plate boundary. It is thus possible that this region may have undergone local deformation separate from the main parts of the Philippine Sea Plate. In this study, we examine the global seismic tomography images of the mantle beneath the Philippine Sea Plate and the marine magnetic field anomaly data at the sea surface from the West Philippine Basin to see whether they agree with the presumed motion of the Philippine Sea Plate. Our comparison between the plate reconstruction and global tomography suggests that the rotation of Philippine Sea Plate may not have been continuous but instead experienced a temporal break at around 32 Ma. The exact nature of this pause is uncertain, but it may be related to a sudden change in the configuration of subduction systems. A detail comparison with recent results from IODP Legs 350 and 351 is therefore necessary, including a search for a change in the depositional style of basin sediment. We also examined the detailed the shape of magnetic anomalies (such as skewness) and compare them with the previous model by allowing the magnetization to have direction corresponding to that during the opening of the West Philippine Basin. At this moment, it is too early to tell if the sudden change at around 32 Ma or other inferred breaks can be seen in the magnetic profiles as well.

  6. Practical automatic Arabic license plate recognition system

    NASA Astrophysics Data System (ADS)

    Mohammad, Khader; Agaian, Sos; Saleh, Hani

    2011-02-01

    Since 1970's, the need of an automatic license plate recognition system, sometimes referred as Automatic License Plate Recognition system, has been increasing. A license plate recognition system is an automatic system that is able to recognize a license plate number, extracted from image sensors. In specific, Automatic License Plate Recognition systems are being used in conjunction with various transportation systems in application areas such as law enforcement (e.g. speed limit enforcement) and commercial usages such as parking enforcement and automatic toll payment private and public entrances, border control, theft and vandalism control. Vehicle license plate recognition has been intensively studied in many countries. Due to the different types of license plates being used, the requirement of an automatic license plate recognition system is different for each country. [License plate detection using cluster run length smoothing algorithm ].Generally, an automatic license plate localization and recognition system is made up of three modules; license plate localization, character segmentation and optical character recognition modules. This paper presents an Arabic license plate recognition system that is insensitive to character size, font, shape and orientation with extremely high accuracy rate. The proposed system is based on a combination of enhancement, license plate localization, morphological processing, and feature vector extraction using the Haar transform. The performance of the system is fast due to classification of alphabet and numerals based on the license plate organization. Experimental results for license plates of two different Arab countries show an average of 99 % successful license plate localization and recognition in a total of more than 20 different images captured from a complex outdoor environment. The results run times takes less time compared to conventional and many states of art methods.

  7. New Tomographic Images of the Yellowstone Plume and its Interaction with the Farallon Plate From the Integrated Analysis of Body and Surface Waves

    NASA Astrophysics Data System (ADS)

    Obrebski, M. J.; Allen, R. M.; Pollitz, F. F.; Porritt, R. W.; Hung, S.

    2010-12-01

    Recent seismic studies have consistently shown that the complex Neogene-Quaternary hot spot track in the Yellowstone-Snake River Plain is underlain by slow, potentially hot material not only in the lithosphere but also deeper into the mantle. The nature of this large region of low velocities, the depth at which it originates, and its possible relation with the Columbia River Basalts and the subduction of the Juan De Fuca-Farallon oceanic plate are still a theme of debate. In an effort to answer these questions, we take advantage of the growing amount of seismic data collected over the Western US to image the velocity structure of the crust and mantle beneath the Pacific Northwest. The compressional (DNA10-P) and shear (DNA10-S) velocity models we present here use seismic data from the Earthscope Transportable Array, regional seismic networks and two Flexible Array experiments (Mendocino and FACES experiments) deployed on the west coast. DNA10-P is a multi-frequency model obtained using finite-frequency sensitivity kernels calculated in 4 frequency bands (0.5-1.25s, 1.25-2.5s, 2.5-10s and 10-50s). Owing to its broad range of periods, this model is characterized by a high resolution below a depth of 50km where the seismic ray paths start crossing each other. DNA10-S is a multi-phase model that includes constraints from teleseismic body waves, ballistic surface waves (periods from 18 to 100s) and Green’s functions extracted from noise correlation (8 to 40s). By inverting jointly these different types of data, we obtain a model with good resolution from the surface down to the lower mantle. Both models show the Yellowstone anomaly as a continuous feature composed of a) and horizontal “head” that spreads in the upper 200km beneath the YSRP, parallel to the direction of the North American Plate and b) a “S”-shaped vertically elongated body that extends continuously from beneath the Yellowstone Caldera down to 1000km depth, the two feature being connected. The

  8. The existence state in the soil of radioactive cesium from the Fukushima Dai-ichi nuclear power plant accident by imaging plate photograph

    NASA Astrophysics Data System (ADS)

    Satou, Yukihiko; Sueki, Keisuke

    2013-04-01

    In the accident of the Fukushima Daiichi nuclear power plant, the wide area in east Japan was polluted seriously with radioactive cesium. But, unlike Chernobyl, reactor core explosion did not occur in Fukushima. Therefore, it is thought that many radioactive nuclides emitted into the atmosphere were in the gas state and aerosol. However, when the imaging plate photographs of the surface soils in Fukushima was observed, many granular radionuclides existed. Then, in order to confirm a radioactive cesium of particle state, the treatment for the soils contaminated with radioactive cesium by using chemical operation was tried. Three type soils, that is, paddy soil, river sediment, and sea sand, were made applicable to research. The contaminated soil samples were collected in Fukushima and Ibaraki prefecture. Radioactivity concentrations of 137Cs and 134Cs were measured by using gamma-ray spectrometry with a high pure germanium (HPGe) detector. After the radioactively measurement, soils had been burned in oven for five hours in 500 degree Celsius. Concentrated hydrochloric acid was added to soil samples, and they were heated for three hours. These samples were divided into residue and elution by centrifugal separation, and then radioactivity of cesium contained in residue was measured. After chemical operations, 70% and 85% of radioactive cesium from river sediment and sea sand were extracted approximately into elution, respectively. In contrast, in the soil of the paddy field, only 30% of radioactive cesium was approximately eluted. When radiation image photograph of the residues of all three types of soils were taken and observed, the granular radioactive nuclides remained clearly in paddy soil and river sediment. In contrast, all the granular radioactive nuclides in sea sand disappeared after treatment. The results of above things that desorption of radioactive cesium depend on the kind of soil. Furthermore, it was suggested that there was radioactive cesium of

  9. Optics for People Stuck in Traffic: License Plates.

    ERIC Educational Resources Information Center

    Chagnon, Paul

    1995-01-01

    Explains the theory behind the working of Scotchlite, a retrodirective material used for coating automotive license plates, and the Ensure Imaging System that allows law enforcement officers to verify the authenticity of the plate. (JRH)

  10. Optics for People Stuck in Traffic: License Plates.

    ERIC Educational Resources Information Center

    Chagnon, Paul

    1995-01-01

    Explains the theory behind the working of Scotchlite, a retrodirective material used for coating automotive license plates, and the Ensure Imaging System that allows law enforcement officers to verify the authenticity of the plate. (JRH)

  11. Rozhen Observatory wide-field plate archives

    NASA Astrophysics Data System (ADS)

    Tsvetkova, K.; Tsvetkov, M.

    2013-01-01

    This paper provides an overview of the wide-field (>10) plate archives at disposal in the Institute of Astronomy and National Astronomical Observatory Rozhen of the Bulgarian Academy of Sciences. The plates with total number 10093 are obtained in the period November 1978 - February 1998 with the 2 m RCC telescope and 50/70/172 cm Schmidt telescope. The available plate catalogues are upgraded with new information, as well as with link to the digitized logbooks (in JPEG file format). The digitization with high quality EPSON flatbed scanners of the available 2 m RCC telescope plates (with low resolution in JPEG, and with high resolution in standardized FITS file format) is accomplished. The digitization of the available 50/70/172 cm Schmidt telescope plates is running. The low resolution images of the scanned Rozhen plates are included in the Wide-Field Plate Database (http://wfpdb.org) and accessible online.

  12. Corrugated cover plate for flat plate collector

    DOEpatents

    Hollands, K. G. Terry; Sibbitt, Bruce

    1978-01-01

    A flat plate radiant energy collector is providing having a transparent cover. The cover has a V-corrugated shape which reduces the amount of energy reflected by the cover away from the flat plate absorber of the collector.

  13. Lasting mantle scars lead to perennial plate tectonics.

    PubMed

    Heron, Philip J; Pysklywec, Russell N; Stephenson, Randell

    2016-06-10

    Mid-ocean ridges, transform faults, subduction and continental collisions form the conventional theory of plate tectonics to explain non-rigid behaviour at plate boundaries. However, the theory does not explain directly the processes involved in intraplate deformation and seismicity. Recently, damage structures in the lithosphere have been linked to the origin of plate tectonics. Despite seismological imaging suggesting that inherited mantle lithosphere heterogeneities are ubiquitous, their plate tectonic role is rarely considered. Here we show that deep lithospheric anomalies can dominate shallow geological features in activating tectonics in plate interiors. In numerical experiments, we found that structures frozen into the mantle lithosphere through plate tectonic processes can behave as quasi-plate boundaries reactivated under far-field compressional forcing. Intraplate locations where proto-lithospheric plates have been scarred by earlier suturing could be regions where latent plate boundaries remain, and where plate tectonics processes are expressed as a 'perennial' phenomenon.

  14. Lasting mantle scars lead to perennial plate tectonics

    PubMed Central

    Heron, Philip J.; Pysklywec, Russell N.; Stephenson, Randell

    2016-01-01

    Mid-ocean ridges, transform faults, subduction and continental collisions form the conventional theory of plate tectonics to explain non-rigid behaviour at plate boundaries. However, the theory does not explain directly the processes involved in intraplate deformation and seismicity. Recently, damage structures in the lithosphere have been linked to the origin of plate tectonics. Despite seismological imaging suggesting that inherited mantle lithosphere heterogeneities are ubiquitous, their plate tectonic role is rarely considered. Here we show that deep lithospheric anomalies can dominate shallow geological features in activating tectonics in plate interiors. In numerical experiments, we found that structures frozen into the mantle lithosphere through plate tectonic processes can behave as quasi-plate boundaries reactivated under far-field compressional forcing. Intraplate locations where proto-lithospheric plates have been scarred by earlier suturing could be regions where latent plate boundaries remain, and where plate tectonics processes are expressed as a ‘perennial' phenomenon. PMID:27282541

  15. Lasting mantle scars lead to perennial plate tectonics

    NASA Astrophysics Data System (ADS)

    Heron, Philip J.; Pysklywec, Russell N.; Stephenson, Randell

    2016-06-01

    Mid-ocean ridges, transform faults, subduction and continental collisions form the conventional theory of plate tectonics to explain non-rigid behaviour at plate boundaries. However, the theory does not explain directly the processes involved in intraplate deformation and seismicity. Recently, damage structures in the lithosphere have been linked to the origin of plate tectonics. Despite seismological imaging suggesting that inherited mantle lithosphere heterogeneities are ubiquitous, their plate tectonic role is rarely considered. Here we show that deep lithospheric anomalies can dominate shallow geological features in activating tectonics in plate interiors. In numerical experiments, we found that structures frozen into the mantle lithosphere through plate tectonic processes can behave as quasi-plate boundaries reactivated under far-field compressional forcing. Intraplate locations where proto-lithospheric plates have been scarred by earlier suturing could be regions where latent plate boundaries remain, and where plate tectonics processes are expressed as a `perennial' phenomenon.

  16. Sputtering and ion plating

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The proceedings of a conference on sputtering and ion plating are presented. Subjects discussed are: (1) concepts and applications of ion plating, (2) sputtering for deposition of solid film lubricants, (3) commercial ion plating equipment, (4) industrial potential for ion plating and sputtering, and (5) fundamentals of RF and DC sputtering.

  17. [Optimisation of the visualisation technique for optical paths through intraocular lenses for characterisation of multifocal imaging properties of Fresnel-zone plates].

    PubMed

    Reiß, S; Forbrig, J; Guthoff, R F; Terwee, T; Stolz, H; Siewert, S; El-Tamer, A; Hinze, U; Chichkov, B N; Stachs, O

    2014-12-01

    The utilisation of the diffractive properties of Fresnel zone plates offers the possibility of intraocular lens designs with multiple foci. Such intraocular lenses can be manufactured by two-photon polymerisation (2PP). This paper explains the underlying concept and shows the principles for visualisation of the focus properties of such implants.

  18. Hyperspectral imaging for differentiating colonies of non-O157 shiga-toxin producing echerichia coli (STEC) serogroups on spread plates of pure cultures

    USDA-ARS?s Scientific Manuscript database

    Direct plating onto solid agar media has been widely used in microbiology laboratories for presumptive-positive pathogen detection in spite of the fact that it is often subjective, labor intensive and time consuming. Rainbow agar is a selective and chromogenic medium that helps to detect pathogenic ...

  19. Coarse Layering at 'Home Plate'

    NASA Technical Reports Server (NTRS)

    2006-01-01

    This image shows coarse-grained layers from around the edge of a low plateau called 'Home Plate' inside Mars' Gusev Crater. One possible origin is material falling to the ground after being thrown aloft by an explosion such as a volcanic eruption or meteorite impact.

    The panoramic camera (Pancam) on NASA's Mars Exploration Rover Spirit acquired the exposures for this image on Spirit's 749th Martian day (Feb. 10, 2006). This view is an approximately true-color rendering mathematically generated from separate images taken through all of the left Pancam's 432-nanometer to 753-nanometer filters.

  20. Complex beam shaping based on an equivalent q-plate system and analysis of its properties using digital holography polarization imaging.

    PubMed

    Yang, Ching-Han; Fuh, Andy Ying-Guey

    2017-06-05

    In this study, we generate various complex beams carrying angular momentum (AM) by using a programmable beam shaping system to mimic typical q-plates. When a circularly polarized wave is incident onto the system, the emerging beam reverses its spin handedness and obtains a spatial phase factor. This phase factor can be engineered by designing a computer-generated hologram (CGH) and applying it to a spatial light modulator (SLM) to produce a beam with controllable spatially distributed orbital angular momentum (OAM) density. To determine the properties of the generated fields, we combine digital holography (DH) with the beam shaping system to yield visualizations of the beam intensity, phase, and AM distributions over the transverse plane at different propagation distances. Comparisons of the theoretically and experimentally obtained results show good qualitative agreement. This study advances our understanding and interpretation of AM characteristics produced by a programmable q-plate-like system.

  1. Null test of aspheric surfaces in zone-plate interferometer

    NASA Astrophysics Data System (ADS)

    Huang, Junejei; Chang, Chihui

    1992-10-01

    Instead of using lenses or mirrors as a null compensator, the construction of the zone plate interferometer is used to accomplish the null test. By choosing the focal length of the zone plate according to the radius of curvature and conic constant of the test surface, the conventional zone plate interferometer is modified to be a null test of concave conicoids. To test convex conicoids, an imaging lens is added between the zone plate and the test surface. As long as the zone plate is perfectly imaged into the center of the curvature of the test surface, a null test of convex conicoids is the same as that of concave ones.

  2. Stability of Three-Layered Annular Plate with Composite Facings

    NASA Astrophysics Data System (ADS)

    Pawlus, D.

    2017-02-01

    Paper presents the behaviour of three-layered annular plates subjected to loads acting in plate plane. Plates are composed of laminated fibre-reinforced composite facings and foam core. The static and dynamic parameters of plate critical state were evaluated. The sensitivity of composite structure of plate to the acting of quickly increasing in time loads is shown. The problem has been solved numerically using the finite element method. Results have been compared with ones obtained for plate models with isotropic layers. These plate models have also been calculated solving formulated task analytically and numerically by means of the finite difference method. Solutions to the problem concern the axisymmetrical and asymmetrical plate buckling modes. Numerous presented tables and figures create the image of the stability behaviour of examined composite plates.

  3. Stability of Three-Layered Annular Plate with Composite Facings

    NASA Astrophysics Data System (ADS)

    Pawlus, D.

    2016-10-01

    Paper presents the behaviour of three-layered annular plates subjected to loads acting in plate plane. Plates are composed of laminated fibre-reinforced composite facings and foam core. The static and dynamic parameters of plate critical state were evaluated. The sensitivity of composite structure of plate to the acting of quickly increasing in time loads is shown. The problem has been solved numerically using the finite element method. Results have been compared with ones obtained for plate models with isotropic layers. These plate models have also been calculated solving formulated task analytically and numerically by means of the finite difference method. Solutions to the problem concern the axisymmetrical and asymmetrical plate buckling modes. Numerous presented tables and figures create the image of the stability behaviour of examined composite plates.

  4. Quantitative ex vivo and in vitro receptor autoradiography using 11C-labeled ligands and an imaging plate: a study with a dopamine D2-like receptor ligand [11C]nemonapride.

    PubMed

    Ishiwata, K; Ogi, N; Tanaka, A; Senda, M

    1999-04-01

    Ex vivo and in vitro autoradiography (ARG) with radioluminography is a useful technique to characterize newly developed 11C-labeled positron emission tomography (PET) tracers and to apply them to biological and pharmacological studies. In this report, we have described a method of evaluating the radioactivity distribution quantitatively in ex vivo and in vitro ARG using imaging plates and a dopamine D2-like receptor ligand [11C]nemonapride as a model compound. The photo-stimulated luminescence (PSL) values of the rat brain section provided by the imaging plates showed an excellent linear relationship with the radioactivity in a wide range under constant slice-thickness, although the PSL values slightly decreased with increasing slice-thickness both in ex vivo and in vitro ARG. The injection dose of 11C-tracers for ex vivo ARG was also discussed. We found saturable binding sites of [11C]nemonapride in the cortex besides the striatum both ex vivo and in vitro.

  5. Williamson Polishing & Plating Site

    EPA Pesticide Factsheets

    Williamson Polishing & Plating Co. Inc. was a plating shop located in the Martindale-Brightwood neighborhood of Indianapolis. The facility conducted job shop polishing and electroplating services. The vacant site contains a 14,651-square-foot building.

  6. Growth Plate Fractures

    MedlinePlus

    ... the most widely used by doctors is the Salter-Harris system, described below. Type I Fractures These ... incidence of growth plate fractures peaks in adolescence. Salter-Harris classification of growth plate fractures. AAOS does ...

  7. Earth's Decelerating Tectonic Plates

    SciTech Connect

    Forte, A M; Moucha, R; Rowley, D B; Quere, S; Mitrovica, J X; Simmons, N A; Grand, S P

    2008-08-22

    Space geodetic and oceanic magnetic anomaly constraints on tectonic plate motions are employed to determine a new global map of present-day rates of change of plate velocities. This map shows that Earth's largest plate, the Pacific, is presently decelerating along with several other plates in the Pacific and Indo-Atlantic hemispheres. These plate decelerations contribute to an overall, globally averaged slowdown in tectonic plate speeds. The map of plate decelerations provides new and unique constraints on the dynamics of time-dependent convection in Earth's mantle. We employ a recently developed convection model constrained by seismic, geodynamic and mineral physics data to show that time-dependent changes in mantle buoyancy forces can explain the deceleration of the major plates in the Pacific and Indo-Atlantic hemispheres.

  8. Accelerated plate tectonics.

    PubMed

    Anderson, D L

    1975-03-21

    The concept of a stressed elastic lithospheric plate riding on a viscous asthenosphere is used to calculate the recurrence interval of great earthquakes at convergent plate boundaries, the separation of decoupling and lithospheric earthquakes, and the migration pattern of large earthquakes along an arc. It is proposed that plate motions accelerate after great decoupling earthquakes and that most of the observed plate motions occur during short periods of time, separated by periods of relative quiescence.

  9. Plating Tank Control Software

    SciTech Connect

    Krafcik, John

    1998-03-01

    The Plating Tank Control Software is a graphical user interface that controls and records plating process conditions for plating in high aspect ratio channels that require use of low current and long times. The software is written for a Pentium II PC with an 8 channel data acquisition card, and the necessary shunt resistors for measuring currents in the millampere range.

  10. Obliquity along plate boundaries

    NASA Astrophysics Data System (ADS)

    Philippon, Mélody; Corti, Giacomo

    2016-12-01

    Most of the plate boundaries are activated obliquely with respect to the direction of far field stresses, as roughly only 8% of the plate boundaries total length shows a very low obliquity (ranging from 0 to 10°, sub-orthogonal to the plate displacement). The obliquity along plate boundaries is controlled by (i) lateral rheological variations within the lithosphere and (ii) consistency with the global plate circuit. Indeed, plate tectonics and magmatism drive rheological changes within the lithosphere and consequently influence strain localization. Geodynamical evolution controls large-scale mantle convection and plate formation, consumption, and re-organization, thus triggering plate kinematics variations, and the adjustment and re-orientation of far field stresses. These geological processes may thus result in plate boundaries that are not perpendicular but oblique to the direction of far field stresses. This paper reviews the global patterns of obliquity along plate boundaries. Using GPlate, we provide a statistical analysis of present-day obliquity along plate boundaries. Within this framework, by comparing natural examples and geological models, we discuss deformation patterns and kinematics recorded along oblique plate boundaries.

  11. Rotatable shear plate interferometer

    DOEpatents

    Duffus, Richard C.

    1988-01-01

    A rotatable shear plate interferometer comprises a transparent shear plate mounted obliquely in a tubular supporting member at 45.degree. with respect to its horizontal center axis. This tubular supporting member is supported rotatably around its center axis and a collimated laser beam is made incident on the shear plate along this center axis such that defocus in different directions can be easily measured.

  12. Impact of ambient lighting intensity and duration on the signal-to-noise ratio of images from photostimulable phosphor plates processed using DenOptix and ScanX systems.

    PubMed

    Ramamurthy, R; Canning, C F; Scheetz, J P; Farman, A G

    2004-09-01

    To evaluate the impact on photostimulable phosphor (PSP) image signal-to-noise ratio (SNR) of pre-scanning ambient lighting exposures. PSP imaging plates (IPs) were exposed to different radiation exposures to achieve flat field images. The exposed IPs were subjected variously to visible light of different intensities (300, 150 or 20 lux) for durations ranging from < 10 s to 120 s. They were processed using laser scanners from two systems for further comparison (DenOptix versus ScanX). Histogram analysis was performed in each case and mean pixel value and its standard deviation were used as surrogates to assess SNR. Statistical methods applied included analysis of variance with Tukey honestly significant difference test for pair wise comparisons. The a priori alpha was set at P < or = 0.05. SNR decreased with increased duration and intensity of pre-scanning light exposure. Lower X-ray exposures resulted in decreased signal resulting in reduced SNR, and increased the need to reduce ambient lighting. No statistically significant differences were found comparing ScanX and DenOptix digital imaging systems in terms of SNR. Reduced ambient lighting is preferred for handling IPs prior to processing in the laser scanner.

  13. Malachite green photosensitive plates.

    PubMed

    Solano, C

    1989-08-15

    An experimental study of the behavior of malachite green sensitized plates was carried out. The transmittance variation of the irradiated plates was taken as a parameter. It has been observed that photoreduction in the malachite green plates is present only when ammonium dichromate is added to the plates. The introduction of external electron donors does not improve the photochemical reaction. It has been determined that malachite green molecules form a weak complex with the dichromate molecules and this complex can only be destroyed photochemically. This effect can explain the limited response of the malachite green dichromated plates.

  14. An improved plating process

    NASA Technical Reports Server (NTRS)

    Askew, John C.

    1994-01-01

    An alternative to the immersion process for the electrodeposition of chromium from aqueous solutions on the inside diameter (ID) of long tubes is described. The Vessel Plating Process eliminates the need for deep processing tanks, large volumes of solutions, and associated safety and environmental concerns. Vessel Plating allows the process to be monitored and controlled by computer thus increasing reliability, flexibility and quality. Elimination of the trivalent chromium accumulation normally associated with ID plating is intrinsic to the Vessel Plating Process. The construction and operation of a prototype Vessel Plating Facility with emphasis on materials of construction, engineered and operational safety and a unique system for rinse water recovery are described.

  15. Angular shear plate

    DOEpatents

    Ruda, Mitchell C [Tucson, AZ; Greynolds, Alan W [Tucson, AZ; Stuhlinger, Tilman W [Tucson, AZ

    2009-07-14

    One or more disc-shaped angular shear plates each include a region thereon having a thickness that varies with a nonlinear function. For the case of two such shear plates, they are positioned in a facing relationship and rotated relative to each other. Light passing through the variable thickness regions in the angular plates is refracted. By properly timing the relative rotation of the plates and by the use of an appropriate polynomial function for the thickness of the shear plate, light passing therethrough can be focused at variable positions.

  16. Multicolor printing plate joining

    NASA Technical Reports Server (NTRS)

    Waters, W. J. (Inventor)

    1984-01-01

    An upper plate having ink flow channels and a lower plate having a multicolored pattern are joined. The joining is accomplished without clogging any ink flow paths. A pattern having different colored parts and apertures is formed in a lower plate. Ink flow channels each having respective ink input ports are formed in an upper plate. The ink flow channels are coated with solder mask and the bottom of the upper plate is then coated with solder. The upper and lower plates are pressed together at from 2 to 5 psi and heated to a temperature of from 295 F to 750 F or enough to melt the solder. After the plates have cooled and the pressure is released, the solder mask is removed from the interior passageways by means of a liquid solvent.

  17. Modic changes in lumbar spine: prevalence and distribution patterns of end plate oedema and end plate sclerosis.

    PubMed

    Xu, Lei; Chu, Bin; Feng, Yang; Xu, Feng; Zou, Yue-Fen

    2016-01-01

    The purpose of this study is to evaluate the distribution of end plate oedema in different types of Modic change especially in mixed type and to analyze the presence of end plate sclerosis in various types of Modic change. 276 patients with low back pain were scanned with 1.5-T MRI. Three radiologists assessed the MR images by T1 weighted, T2 weighted and fat-saturation T2 weighted sequences and classified them according to the Modic changes. Pure oedematous end plate signal changes were classified as Modic Type I; pure fatty end plate changes were classified as Modic Type II; and pure sclerotic end plate changes as Modic Type III. A mixed feature of both Types I and II with predominant oedematous signal change is classified as Modic I-II, and a mixture of Types I and II with predominant fatty change is classified as Modic II-I. Thus, the mixed types can further be subdivided into seven subtypes: Types I-II, Types II-I, Types I-III, Types III-I, Types II-III, Types III-II and Types I-III. During the same period, 52 of 276 patients who underwent CT and MRI were retrospectively reviewed to determine end plate sclerosis. (1) End plate oedema: of the 2760 end plates (276 patients) examined, 302 end plates showed Modic changes, of which 82 end plates showed mixed Modic changes. The mixed Modic changes contain 92.7% of oedematous changes. The mixed types especially Types I-II and Types II-I made up the majority of end plate oedematous changes. (2) End plate sclerosis: 52 of 276 patients were examined by both MRI and CT. Of the 520 end plates, 93 end plates showed Modic changes, of which 34 end plates have shown sclerotic changes in CT images. 11.8% of 34 end plates have shown Modic Type I, 20.6% of 34 end plates have shown Modic Type II, 2.9% of 34 end plates have shown Modic Type III and 64.7% of 34 end plates have shown mixed Modic type. End plate oedema makes up the majority of mixed types especially Types I-II and Types II-I. The end plate sclerosis on CT images may

  18. High resolution receiver function Images of the lithosphere beneath the Central Andes between 19°and 24° S using data of Integrated Plate boundary Observatory Chile (IPOC)

    NASA Astrophysics Data System (ADS)

    Sodoudi, F.; Asch, G.; Kind, R.; Oncken, O.; Vilotte, J.; Barrientos, S. E.; Salazar Reinoso, P.

    2009-12-01

    Installation of observatories in northern Chile started in 2006 in a close cooperation of the Universidad de Chile (Santiago), the Universidad Catolica del Norte (Antofagasta), the IPGP (Paris), and the GFZ Potsdam. Currently we operate 16 modern seismological stations equipped with STS-2 broadband seismometers. All seismic stations are located in northern Chile at 19°-24° S between Arica in the North and Antofagasta in the South. Due to the large amount of the available data, it is now possible to obtain detailed geometry of the subducting Nazca plate as well as that of the continental South American plate in northern Chile with so far unprecedented resolution. The lower boundary of the lithospheric plates, which is poorly observed by seismic means, has remained as an exotic boundary. Even though, seismic surface waves can image the asthenosphere as a low velocity zone. The Lithosphere-Asthenosphere Boundary (LAB) resolved by surface waves can be only considered as a broad transition zone due to the large wavelength of the surface waves. Seismic techniques which use converted body waves are now far enough developed to be successful in observing the LAB with a higher resolution than known so far. The principle of the receiver function technique is that a strong teleseismic mother phase (e.g. P or S) incident on the discontinuity beneath a station produces a small converted phase (P-to-S or S-to-P) which indicates its properties. We combined here these two methods (P and S receiver function) to have the best vertical as well as horizontal coverage of the area. P receiver function analysis using P-to-S converted waves was used as the main tool to map the crustal structure. More than 120 P receiver functions obtained from each station enabled us to detect even small azimuthal structural differences. While P receiver functions provided a clear Image of the Moho topography, S receiver functions (using S-to-P converted waves) were used to detect the Lithosphere

  19. Development efforts to improve curved-channel microchannel plates

    NASA Technical Reports Server (NTRS)

    Corbett, M. B.; Feller, W. B.; Laprade, B. N.; Cochran, R.; Bybee, R.; Danks, A.; Joseph, C.

    1993-01-01

    Curved-channel microchannel plate (C-plate) improvements resulting from an ongoing NASA STIS microchannel plate (MCP) development program are described. Performance limitations of previous C-plates led to a development program in support of the STIS MAMA UV photon counter, a second generation instrument on the Hubble Space Telescope. C-plate gain, quantum detection efficiency, dark noise, and imaging distortion, which are influenced by channel curvature non-uniformities, have all been improved through use of a new centrifuge fabrication technique. This technique will be described, along with efforts to improve older, more conventional shearing methods. Process optimization methods used to attain targeted C-plate performance goals will be briefly characterized. Newly developed diagnostic measurement techniques to study image distortion, gain uniformity, input bias angle, channel curvature, and ion feedback, will be described. Performance characteristics and initial test results of the improved C-plates will be reported. Future work and applications will also be discussed.

  20. Development efforts to improve curved-channel microchannel plates

    NASA Technical Reports Server (NTRS)

    Corbett, M. B.; Feller, W. B.; Laprade, B. N.; Cochran, R.; Bybee, R.; Danks, A.; Joseph, C.

    1993-01-01

    Curved-channel microchannel plate (C-plate) improvements resulting from an ongoing NASA STIS microchannel plate (MCP) development program are described. Performance limitations of previous C-plates led to a development program in support of the STIS MAMA UV photon counter, a second generation instrument on the Hubble Space Telescope. C-plate gain, quantum detection efficiency, dark noise, and imaging distortion, which are influenced by channel curvature non-uniformities, have all been improved through use of a new centrifuge fabrication technique. This technique will be described, along with efforts to improve older, more conventional shearing methods. Process optimization methods used to attain targeted C-plate performance goals will be briefly characterized. Newly developed diagnostic measurement techniques to study image distortion, gain uniformity, input bias angle, channel curvature, and ion feedback, will be described. Performance characteristics and initial test results of the improved C-plates will be reported. Future work and applications will also be discussed.

  1. Imaging the Structure of the Pacific-North American Plate Boundary using Airborne Laser Swath Mapping (ALSM) Data and Wavelet Analysis

    NASA Astrophysics Data System (ADS)

    Sanquini, A.; Cheung, K.; Gudmundsdottir, M. H.; Moon, S.; Lin, N.; Shelef, E.; Hilley, G. E.; Prentice, C. S.

    2011-12-01

    Since the 1906 San Francisco earthquake, geologists have noted that the topography of active fault zones is significantly modified by repeated fault ruptures over geologic time. Here, we present an analysis of fault zone topography generated by high-resolution Airborne Laser Swath Mapping (ALSM) data collected by the National Center for Airborne Laser Mapping (NCALM). The digital elevation models (DEMs) generated from the ALSM data reveal the location, orientation, and curvature of scarps associated with active, plate-boundary faults. In particular, we have examined topographic data from the B4 and Northern California data sets, as well as data from faults within the Eastern California Shear Zone. We used a wavelet-based convolution scheme, based on topographic forms modified from the profile scarp-diffusion model of Hanks et al. (1984), extended to encompass along-strike features. We applied this filtering methodology to digital topography along fault zones to estimate the best-fitting height, orientation, morphologic age, and associated Signal-to-Noise Ratio (SNR) of scarps found within these datasets. These results will be available to the community via a GIS web portal so that other workers can mine these data to understand patterns of fault-zone structure observed along the plate-bounding fault zones. To evaluate the utility of this methodology for identifying and characterizing fault scarps within the topographic swaths, we present sample results from the Calaveras fault, part of the San Andreas fault system in northern California. We found that along this fault, the filtering algorithm correctly identifies scarps characterized by ground surveys, previous analysis of aerial photography, and/or field mapping. However, some mapped fault traces with low SNR values because of their subtle morphologic expression are not identified by the algorithm. Similarly, some fluvial scarps that trend in a similar orientation to the overall fault zone are erroneously

  2. The North American Astronomical Photographic Plate Center: Phase I.

    NASA Astrophysics Data System (ADS)

    Cline, J. D.; Castelaz, M. W.; Crowley, T.; Griffin, E.; Osborn, W.

    2004-05-01

    Astronomical photographic plates constitute an important and, for the large part, unrepeatable resource for research. International pressure is mounting to preserve and catalog scientifically valuable plate collections and capture their information through digitization. At the same time, many institutions holding plates now lack the space, funds and expertise to adequately preserve this important material. In response, the Pisgah Astronomical Research Institute has established the North American Photographic Plate Center (NAPPC). NAPPC is intended as a long-term repository for direct and objective prism plate collections currently stored in North America. PARI is a natural location for such a center. It offers physically secure and abundant environmentally controlled space for plate storage as well as Internet 2 infrastructure and instrument space necessary for the eventual digitization and Internet distribution of images. Phase I of this initiative is to collect unwanted plate collections, store them in an appropriate manner, prepare catalogues of their relevant information and establish a laboratory for on-site examination or measurement of the plates. This is currently underway. Phase II will be the eventual digitization and development of a public web accessible database of images. We will describe the procedures for placing plate collections in NAPPC, the infrastructure in place for plate storage and measurement, and our preliminary plans for making the plate archive a public image library with Internet access.

  3. Demonstration of accuracy and clinical versatility of mutual information for automatic multimodality image fusion using affine and thin-plate spline warped geometric deformations.

    PubMed

    Meyer, C R; Boes, J L; Kim, B; Bland, P H; Zasadny, K R; Kison, P V; Koral, K; Frey, K A; Wahl, R L

    1997-04-01

    This paper applies and evaluates an automatic mutual information-based registration algorithm across a broad spectrum of multimodal volume data sets. The algorithm requires little or no pre-processing, minimal user input and easily implements either affine, i.e. linear or thin-plate spline (TPS) warped registrations. We have evaluated the algorithm in phantom studies as well as in selected cases where few other algorithms could perform as well, if at all, to demonstrate the value of this new method. Pairs of multimodal gray-scale volume data sets were registered by iteratively changing registration parameters to maximize mutual information. Quantitative registration errors were assessed in registrations of a thorax phantom using PET/CT and in the National Library of Medicine's Visible Male using MRI T2-/T1-weighted acquisitions. Registrations of diverse clinical data sets were demonstrated including rotate-translate mapping of PET/MRI brain scans with significant missing data, full affine mapping of thoracic PET/CT and rotate-translate mapping of abdominal SPECT/CT. A five-point thin-plate spline (TPS) warped registration of thoracic PET/CT is also demonstrated. The registration algorithm converged in times ranging between 3.5 and 31 min for affine clinical registrations and 57 min for TPS warping. Mean error vector lengths for rotate-translate registrations were measured to be subvoxel in phantoms. More importantly the rotate-translate algorithm performs well even with missing data. The demonstrated clinical fusions are qualitatively excellent at all levels. We conclude that such automatic, rapid, robust algorithms significantly increase the likelihood that multimodality registrations will be routinely used to aid clinical diagnoses and post-therapeutic assessment in the near future.

  4. Composite plates impact damage - An atlas

    NASA Technical Reports Server (NTRS)

    Finn, Scott R.; Springer, George S.

    1991-01-01

    The present volume on impact damage in composite plates presents an extensive compendium of visual and graphic data regarding a variety of material and impactor parameters. The photographs are taken with X-ray and C-scan imaging in conjunction with a dye penetrant to show matrix cracks and delaminations. Impact and static-loading tests are performed on plates of graphite-epoxy, graphite-toughened epoxy, and graphite-PEEK materials. The images are presented to yield specific visual data regarding such parameters as impactor velocity, thickness of the back ply group, impactor nose radius, and the effects of multiple delaminations. The images are grouped in eight subsets that correspond to parameters including plate length, material, and the difference in fiber orientation between adjacent ply groups. This substantial volume represents a systematic effort to study the effects of several material parameters on impact damage.

  5. Composite plates impact damage - An atlas

    NASA Technical Reports Server (NTRS)

    Finn, Scott R.; Springer, George S.

    1991-01-01

    The present volume on impact damage in composite plates presents an extensive compendium of visual and graphic data regarding a variety of material and impactor parameters. The photographs are taken with X-ray and C-scan imaging in conjunction with a dye penetrant to show matrix cracks and delaminations. Impact and static-loading tests are performed on plates of graphite-epoxy, graphite-toughened epoxy, and graphite-PEEK materials. The images are presented to yield specific visual data regarding such parameters as impactor velocity, thickness of the back ply group, impactor nose radius, and the effects of multiple delaminations. The images are grouped in eight subsets that correspond to parameters including plate length, material, and the difference in fiber orientation between adjacent ply groups. This substantial volume represents a systematic effort to study the effects of several material parameters on impact damage.

  6. GOLD PLATING PROCESS

    DOEpatents

    Seegmiller, R.

    1957-08-01

    An improved bath is reported for plating gold on other metals. The composition of the plating bath is as follows: Gold cyanide from about 15 to about 50 grams, potassium cyanide from about 70 to about 125 grams, and sulfonated castor oil from about 0.1 to about 10 cc. The gold plate produced from this bath is smooth, semi-hard, and nonporous.

  7. Plating methods, a survey

    NASA Technical Reports Server (NTRS)

    Berkowitz, J. B.; Emerson, N. H.

    1972-01-01

    Results are presented of a comprehensive search of the literature available, much of which has been generated by the research centers of NASA and its contractors, on plating and coating methods and techniques. Methods covered included: (1) electroplating from aqueous solutions; (2) electroplating from nonaqueous solutions; (3) electroplating from fused-salt baths; (4) electroforming; (5) electroless plating, immersion plating, and mirroring; (6) electroplating from gaseous plasmas; and (7) anodized films and conversion coatings.

  8. PLATES WITH OXIDE INSERTS

    DOEpatents

    West, J.M.; Schumar, J.F.

    1958-06-10

    Planar-type fuel assemblies for nuclear reactors are described, particularly those comprising fuel in the oxide form such as thoria and urania. The fuel assembly consists of a plurality of parallel spaced fuel plate mennbers having their longitudinal side edges attached to two parallel supporting side plates, thereby providing coolant flow channels between the opposite faces of adjacent fuel plates. The fuel plates are comprised of a plurality of longitudinally extending tubular sections connected by web portions, the tubular sections being filled with a plurality of pellets of the fuel material and the pellets being thermally bonded to the inside of the tubular section by lead.

  9. CALUTRON FACE PLATE

    DOEpatents

    Brobeck, W.M.

    1959-08-25

    The construction of a removable cover plate for a calutron tank is described. The plate is fabricated of a rectangular frame member to which is welded a bowed or dished plate of thin steel, reinforced with transverse stiffening ribs. When the tank is placed between the poles of a magnet, the plate may be pivoted away from the tank and magnet and is adapted to support the ion separation mechanism secured to its inner side as well as the vacuum load within the tank.

  10. Spirit Beside 'Home Plate,' Sol 1809

    NASA Technical Reports Server (NTRS)

    2009-01-01

    NASA Mars Exploration Rover Spirit used its navigation camera to take the images assembled into this 120-degree view southward after a short drive during the 1,809th Martian day, or sol, of Spirit's mission on the surface of Mars (February 3, 2009).

    Spirit had driven about 2.6 meters (8.5 feet) that sol, continuing a clockwise route around a low plateau called 'Home Plate.' In this image, the rocks visible above the rovers' solar panels are on the slope at the northern edge of Home Plate.

    This view is presented as a cylindrical projection with geometric seam correction.

  11. Characteristics of a microchannel plate intensifier

    NASA Technical Reports Server (NTRS)

    Sandie, W. G.; Mende, S. B.

    1982-01-01

    A telephoto optical system has been designed for imaging applications involving a use of the spectral region from 2000 to 7500 A. The optics images onto the photocathode of a multichannel plate photomultiplier (PMT). Interference filters are employed to provide spectral selectivity. The PMT consists of three microchannel plate intensifiers (MCP), arranged in a 'Z' configuration. MCP photomultiplier pulse height distributions are discussed along with aspects of spatial distribution, the electron gain pulse height distribution, and the charge loss due to edge effects. Attention is given to the electron gain pulse height distribution obtained from four anodes connected in parallel, taking into account a uniform illumination of the photocathode.

  12. Spirit Beside 'Home Plate,' Sol 1809

    NASA Technical Reports Server (NTRS)

    2009-01-01

    NASA Mars Exploration Rover Spirit used its navigation camera to take the images assembled into this 120-degree view southward after a short drive during the 1,809th Martian day, or sol, of Spirit's mission on the surface of Mars (February 3, 2009).

    Spirit had driven about 2.6 meters (8.5 feet) that sol, continuing a clockwise route around a low plateau called 'Home Plate.' In this image, the rocks visible above the rovers' solar panels are on the slope at the northern edge of Home Plate.

    This view is presented as a cylindrical projection with geometric seam correction.

  13. Plating Inc. Site

    EPA Pesticide Factsheets

    EPA will begin a hazardous waste cleanup at Plating Inc., an abandoned zinc and chromate plating facility at 888 N. Prior Ave. in St. Paul. The abandoned facility houses approximately 82 open chemical vats containing hazardous wastes such as cyanide, caust

  14. Earthquakes and plate tectonics

    USGS Publications Warehouse

    Spall, H.

    1977-01-01

    An explanation is to be found in plate tectonics, a concept which has revolutionized thinking in the Earth sciences in the last 10 years. The theory of plate tectonics combines many of the ideas about continental drift (originally proposed in 1912 by Alfred Wegener in Germany) and sea-floor spreading (suggested originally by Harry Hess of Princeton University). 

  15. Blue Willow Story Plates

    ERIC Educational Resources Information Center

    Fontes, Kris

    2009-01-01

    In the December 1997 issue of "SchoolArts" is a lesson titled "Blue Willow Story Plates" by Susan Striker. In this article, the author shares how she used this lesson with her middle-school students many times over the years. Here, she describes a Blue Willow plate painting project that her students made.

  16. Blue Willow Story Plates

    ERIC Educational Resources Information Center

    Fontes, Kris

    2009-01-01

    In the December 1997 issue of "SchoolArts" is a lesson titled "Blue Willow Story Plates" by Susan Striker. In this article, the author shares how she used this lesson with her middle-school students many times over the years. Here, she describes a Blue Willow plate painting project that her students made.

  17. Methods for testing Zernike phase plates and a report on silicon-based phase plates with reduced charging and improved ageing characteristics.

    PubMed

    Marko, Michael; Meng, Xing; Hsieh, Chyongere; Roussie, James; Striemer, Christopher

    2013-11-01

    Imaging with Zernike phase plates is increasingly being used in cryo-TEM tomography and cryo-EM single-particle applications. However, rapid ageing of the phase plates, together with the cost and effort in producing them, present serious obstacles to widespread adoption. We are experimenting with phase plates based on silicon chips that have thin windows; such phase plates could be mass-produced and made available at moderate cost. The windows are coated with conductive layers to reduce charging, and this considerably extends the useful life of the phase plates compared to traditional pure-carbon phase plates. However, a compromise must be reached between robustness and transmission through the phase-plate film. Details are given on testing phase-plate performance by means of imaging an amorphous thin film and evaluating the power spectra of the images.

  18. Methods for testing Zernike phase plates and a report on silicon-based phase plates with reduced charging and improved ageing characteristics

    PubMed Central

    Marko, Michael; Meng, Xing; Hsieh, Chyongere; Roussie, James; Striemer, Christopher

    2013-01-01

    Imaging with Zernike phase plates is increasingly being used in cryo-TEM tomography and cryo-EM single-particle applications. However, rapid ageing of the phase plates, together with the cost and effort in producing them, present serious obstacles to widespread adoption. We are experimenting with phase plates based on silicon chips that have thin windows; such phase plates could be mass-produced and made available at moderate cost. The windows are coated with conductive layers to reduce charging, and this considerably extends the useful life of the phase plates compared to traditional pure-carbon phase plates. However, a compromise must be reached between robustness and transmission through the phase-plate film. Details are given on testing phase-plate performance by means of imaging an amorphous thin film and evaluating the power spectra of the images. PMID:23994351

  19. Spirit Begins Drive Around Home Plate

    NASA Technical Reports Server (NTRS)

    2009-01-01

    The hazard avoidance camera on the front of NASA's Mars Exploration Rover Spirit took this image after a drive by Spirit on the 1,829th Martian day, or sol, of Spirit's mission on the surface of Mars (Feb. 24, 2009).

    On Sol 1829, Spirit drove 6.29 meters (21 feet) northwestward, away from the northern edge of the low plateau called 'Home Plate.' The track dug by the dragged right-front wheel as the rover drove backward is visible in this image, receding toward the southeast. Rock layers of the northern slope of Home Plate are visible in the upper right portion of the image.

    In sols prior to 1829, the rover team had been trying to maneuver Spirit to climb onto the northern edge of Home Plate, ready to drive southward across the top of the plateau toward science destinations south of Home Plate. The Sol 1829 drive was the first move of a revised strategy to circle at least partway around Home Plate on the trek toward the sites south of the plateau.

  20. Spirit Begins Drive Around Home Plate

    NASA Technical Reports Server (NTRS)

    2009-01-01

    The hazard avoidance camera on the front of NASA's Mars Exploration Rover Spirit took this image after a drive by Spirit on the 1,829th Martian day, or sol, of Spirit's mission on the surface of Mars (Feb. 24, 2009).

    On Sol 1829, Spirit drove 6.29 meters (21 feet) northwestward, away from the northern edge of the low plateau called 'Home Plate.' The track dug by the dragged right-front wheel as the rover drove backward is visible in this image, receding toward the southeast. Rock layers of the northern slope of Home Plate are visible in the upper right portion of the image.

    In sols prior to 1829, the rover team had been trying to maneuver Spirit to climb onto the northern edge of Home Plate, ready to drive southward across the top of the plateau toward science destinations south of Home Plate. The Sol 1829 drive was the first move of a revised strategy to circle at least partway around Home Plate on the trek toward the sites south of the plateau.

  1. Turbine vane plate assembly

    DOEpatents

    Schiavo Jr., Anthony L.

    2006-01-10

    A turbine vane assembly includes a turbine vane having first and second shrouds with an elongated airfoil extending between. Each end of the airfoil transitions into a shroud at a respective junction. Each of the shrouds has a plurality of cooling passages, and the airfoil has a plurality of cooling passages extending between the first and second shrouds. A substantially flat inner plate and an outer plate are coupled to each of the first and second shrouds so as to form inner and outer plenums. Each inner plenum is defined between at least the junction and the substantially flat inner plate; each outer plenum is defined between at least the substantially flat inner plate and the outer plate. Each inner plenum is in fluid communication with a respective outer plenum through at least one of the cooling passages in the respective shroud.

  2. Is There Really A North American Plate?

    NASA Astrophysics Data System (ADS)

    Krill, A.

    2011-12-01

    Lithospheric plates are typically identified from earthquake epicenters and evidence such as GPS movements. But no evidence indicates a plate boundary between the North American and South American Plates. Some plate maps show them separated by a transform boundary, but it is only a fracture zone. Other maps show an "undefined plate boundary" or put no boundary between these two plates (check Google images). Early plate maps showed a single large American Plate, quite narrow east of the Caribbean Plate (Le Pichon 1968, Morgan 1968). The North and South American Plates became established by the leading textbook Earth (Press & Siever 1974). On their map, from a Scientific American article by John Dewey (1972), these new plates were separated by an "uncertain plate boundary." The reasons for postulating a North American Plate were probably more psychological than geological. Each of the other continents of the world had its own plate, and North American geologists naturally wanted theirs. Similarly, European geographers used to view Europe as its own continent. A single large plate should again be hypothesized. But the term American Plate would now be ambiguous ("Which plate, North or South?") Perhaps future textbook authors could call it the "Two-American Plate." Textbook authors ultimately decide such global-tectonic matters. I became aware of textbook authors' opinions and influence from my research into the history of Alfred Wegener's continental drift (see Fixists vs. Mobilists by Krill 2011). Leading textbook author Charles Schuchert realized that continental drift would abolish his cherished paleogeographic models of large east-west continents (Eria, Gondwana) and small oceans (Poseiden, Nereis). He and his junior coauthors conspired to keep drift evidence out of their textbooks, from the 1934-editions until the 1969-editions (Physical Geology by Longwell et al. 1969, Historical Geology by Dunbar & Waage 1969). Their textbooks ruled in America. Textbooks

  3. Ornament Problem Suppression in Indonesian License Plate Recognition Systems

    NASA Astrophysics Data System (ADS)

    Mahatmaputra Tedjojuwono, Samuel

    2017-03-01

    Based on the original work of fast performance algorithm in detecting Indonesian license plate, the proposed work will solve the error found in the license plate localization process caused by plate like pattern within the image, which was called the ornament problem. Although not in all cases, this problem could exist when a car has banner, regular pattern, car’s front grill, that could miss understood by the system as license plate letters. The proposed work will implement filtering systems instead of machine learning approach. The filtering methods will follows three steps: detection filter based on the number of elements in the vector, based on the letter proportion of a license plate number, and based on the distance between detected letters. This approach will maintain the fast properties of the original algorithm and will increase the accuracy of localizing the license plate within the given image.

  4. Episodic plate tectonics on Venus

    NASA Technical Reports Server (NTRS)

    Turcotte, Donald

    1992-01-01

    Studies of impact craters on Venus from the Magellan images have placed important constraints on surface volcanism. Some 840 impact craters have been identified with diameters ranging from 2 to 280 km. Correlations of this impact flux with craters on the Moon, Earth, and Mars indicate a mean surface age of 0.5 +/- 0.3 Ga. Another important observation is that 52 percent of the craters are slightly fractured and only 4.5 percent are embayed by lava flows. These observations led researchers to hypothesize that a pervasive resurfacing event occurred about 500 m.y. ago and that relatively little surface volcanism has occurred since. Other researchers have pointed out that a global resurfacing event that ceased about 500 MYBP is consistent with the results given by a recent study. These authors carried out a series of numerical calculations of mantle convection in Venus yielding thermal evolution results. Their model considered crustal recycling and gave rapid planetary cooling. They, in fact, suggested that prior to 500 MYBP plate tectonics was active in Venus and since 500 MYBP the lithosphere has stabilized and only hot-spot volcanism has reached the surface. We propose an alternative hypothesis for the inferred cessation of surface volcanism on Venus. We hypothesize that plate tectonics on Venus is episodic. Periods of rapid plate tectonics result in high rates of subduction that cool the interior resulting in more sluggish mantle convection.

  5. Potsdam Carte du Ciel Plates: Present Inventory and Future Potential

    NASA Astrophysics Data System (ADS)

    Tsvetkova, Katya; Tsvetkov, Milcho; Boehm, Petra; Steinmetz, Matthias; Dick, Wolfgang R.

    2007-08-01

    We present here the inventory of Potsdam CdC plates stored in the Astrophysical Institute Potsdam (AIP). The Potsdam CdC zone ( +32 to +39 degrees) was divided into 1232 fields. The total number of all CdC plates obtained in Potsdam is about 2160. Only 963 plates (45% of all) are now stored in AIP. The first epoch plates had been obtained during the period July 1893 - August 1902. The second epoch plates (August 1913 - February 1924) can be separated into two time intervals according to the main observer and the observing method used: from August 1913 till July 1914 and from February 1916 - February 1924. Our intension is to give on-line access to the plate information, as well as to the digitized plate images in near future using the EPSON 10000XL flatbed scanner.

  6. Comparison of intraoperative flat panel imaging and postoperative plain radiography for the detection of intraarticular screw displacement in volar distal radius plate ostheosynthesis.

    PubMed

    Borggrefe, J; Bolte, H; Worms, W; Mahlke, L; Seekamp, A; Menzdorf, L; Varoga, D; Müller, M; Weuster, M; Zorenkov, D; Wedel, T; Lippross, S

    2015-12-01

    To investigate if intraoperative 3D flat panel imaging improves the detection of radiocarpal intraarticular screw misplacement (RCSM) in comparison to standard postoperative x-ray. In a study on cadaver specimens, we evaluated the sensitivity and specificity to detect RCSM using X-ray, intraoperative 3D-fluoroscopy as well as the digital volume tomography. The gold standard reference was computed tomography. Sensitivity for the detection of RCSM for X-ray was 58% and specificity 88%. For DVT, the sensitivity to detect RCSM was 88% and the specificity 53%. For 3D-fluoroscopy, the sensitivity for RCSM was 68% and specificity 95%. When combining the methods, the best performance was found, when combining the two intraoperative imaging methods, with a resulting sensitivity of 88% and a specificity of 73%. Intraoperative 3D fluoroscopy and digital volume tomography appear to be at least as sensitive and specific to detect RCSM than the regular postoperative radiography in two planes. However, especially discrete screw misplacements can be missed with either method. Level IV. Diagnostic device study. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  7. Earthquakes and plate tectonics.

    USGS Publications Warehouse

    Spall, H.

    1982-01-01

    Earthquakes occur at the following three kinds of plate boundary: ocean ridges where the plates are pulled apart, margins where the plates scrape past one another, and margins where one plate is thrust under the other. Thus, we can predict the general regions on the earth's surface where we can expect large earthquakes in the future. We know that each year about 140 earthquakes of magnitude 6 or greater will occur within this area which is 10% of the earth's surface. But on a worldwide basis we cannot say with much accuracy when these events will occur. The reason is that the processes in plate tectonics have been going on for millions of years. Averaged over this interval, plate motions amount to several mm per year. But at any instant in geologic time, for example the year 1982, we do not know, exactly where we are in the worldwide cycle of strain build-up and strain release. Only by monitoring the stress and strain in small areas, for instance, the San Andreas fault, in great detail can we hope to predict when renewed activity in that part of the plate tectonics arena is likely to take place. -from Author

  8. Astrometry with AC and CdC Plates of Córdoba: Evaluation of Errors

    NASA Astrophysics Data System (ADS)

    Giuppone, C. A.; Bustos Fierro, I. H.; Calderón, J. H.

    2006-01-01

    This paper examines the methodology for the identification of stellar images in Carte du Ciel and Astrographic Catalog plates. Four CdC plates and one AC plate of the Córdoba plates collection digitized through MAMA were employed for the study. Centering errors between 0''.08 and 0''.17 were found. These errors depend on the distance to the plate centre. This accuracy is suitable for the utilization of these plates in astrometric programs. Morphological parameters of images were also evaluated.

  9. Principal visual word discovery for automatic license plate detection.

    PubMed

    Zhou, Wengang; Li, Houqiang; Lu, Yijuan; Tian, Qi

    2012-09-01

    License plates detection is widely considered a solved problem, with many systems already in operation. However, the existing algorithms or systems work well only under some controlled conditions. There are still many challenges for license plate detection in an open environment, such as various observation angles, background clutter, scale changes, multiple plates, uneven illumination, and so on. In this paper, we propose a novel scheme to automatically locate license plates by principal visual word (PVW), discovery and local feature matching. Observing that characters in different license plates are duplicates of each other, we bring in the idea of using the bag-of-words (BoW) model popularly applied in partial-duplicate image search. Unlike the classic BoW model, for each plate character, we automatically discover the PVW characterized with geometric context. Given a new image, the license plates are extracted by matching local features with PVW. Besides license plate detection, our approach can also be extended to the detection of logos and trademarks. Due to the invariance virtue of scale-invariant feature transform feature, our method can adaptively deal with various changes in the license plates, such as rotation, scaling, illumination, etc. Promising results of the proposed approach are demonstrated with an experimental study in license plate detection.

  10. Digital Copy of the Pulkovo Plate Collection

    NASA Astrophysics Data System (ADS)

    Kanaev, I.; Kanaeva, N.; Poliakow, E.; Pugatch, T.

    Report is devoted to a problem of saving of the Pulkovo plate collection. In total more than 50 thousand astronegatives are stored in the observatory. First of them are dated back to 1893. A risk of emulsion corrupting raises with current of time. Since 1996 the operation on digitization and record of the images of plates on electronic media (HDD, CD) are carried out in the observatory. The database ECSIP - Electronic Collection of the Star Images of the Pulkovo is created. There are recorded in it both complete, and extracted (separate areas) images of astronegatives. The plates as a whole are scanned on the photoscanner with rather rough optical resolution 600-2400 dpi. The matrixes with the separate images are digitized on the precision measuring machine "Fantasy" with high (6000-25400 dpi) resolution. The DB ECSIP allows to accept and to store different types of data of a matrix structure, including, CCD-frames. Structure of the ECSIP's software includes systems of visualization, processing and manipulation by the images, and also programs for position and photometric measurements. To the present time more than 40% completed and 10% extracted images from its total amount are digitized and recorded in DB ECSIP. The project is fulfilled at financial support by the Ministry of Science of Russian Federation, grant 01-54 "The coordinate -measuring astrographic machine "Fantasy".

  11. What's On Your Plate?

    MedlinePlus

    ... Table of Contents What's On Your Plate? Smart Food Choices for Healthy Aging www.nia.nih.gov/health/ ... calories in" and "calories out," and making good food choices as you age. Shopping Tips See how planning ...

  12. Feynman's wobbling plate

    NASA Astrophysics Data System (ADS)

    Tuleja, Slavomir; Gazovic, Boris; Tomori, Alexander; Hanc, Jozef

    2007-03-01

    In the book Surely You Are Joking, Mr. Feynman! Richard Feynman tells a story of a Cornell cafeteria plate being tossed into the air. As the plate spun, it wobbled. Feynman noticed a relation between the two motions. He solved the motion of the plate by using the Lagrangian approach. This solution didn't satisfy him. He wanted to understand the motion of the plate by analyzing the motion of its individual particles and the forces acting on them. He was successful, but he didn't tell us how he did it. We provide an elementary explanation for the two-to-one ratio of wobble to spin frequencies, based on an analysis of the motion of the particles and the forces acting on them. We also demonstrate the power of numerical simulation and computer animation to provide insight into a physical phenomenon and guidance on how to do the analysis.

  13. Reduction of astrometric plates

    NASA Technical Reports Server (NTRS)

    Stock, J.

    1984-01-01

    A rapid and accurate method for the reduction of comet or asteroid plates is described. Projection equations, scale length correction, rotation of coordinates, linearization, the search for additional reference stars, and the final solution are examined.

  14. Violin plate modes.

    PubMed

    Gough, Colin

    2015-01-01

    As the first step toward developing a generic model for the acoustically radiating vibrational modes of the violin and related instruments, the modes of both freely supported and edge-constrained top and back plates have been investigated as functions of shape, arching height, elastic anisotropy, the f-holes and associated island area, thickness graduations, and the additional boundary constraints of the ribs, soundpost, and bass-bar present in the assembled instrument. Comsol shell structure finite element software has been used as a quasi-experimental tool, with physical and geometric properties varied smoothly, often over several orders of magnitude, allowing the development of the plate modes to be followed continuously from those of an initially square plate to those of doubly-arched, guitar-shaped, orthotropic plates and their dependence on all the above factors.

  15. Reduction of astrometric plates

    NASA Technical Reports Server (NTRS)

    Stock, J.

    1984-01-01

    A rapid and accurate method for the reduction of comet or asteroid plates is described. Projection equations, scale length correction, rotation of coordinates, linearization, the search for additional reference stars, and the final solution are examined.

  16. Tectonic Plate Movement.

    ERIC Educational Resources Information Center

    Landalf, Helen

    1998-01-01

    Presents an activity that employs movement to enable students to understand concepts related to plate tectonics. Argues that movement brings topics to life in a concrete way and helps children retain knowledge. (DDR)

  17. Plate tectonics: Metamorphic myth

    NASA Astrophysics Data System (ADS)

    Korenaga, Jun

    2016-01-01

    Clear evidence for subduction-induced metamorphism, and thus the operation of plate tectonics on the ancient Earth has been lacking. Theoretical calculations indicate that we may have been looking for something that cannot exist.

  18. Tectonic Plate Movement.

    ERIC Educational Resources Information Center

    Landalf, Helen

    1998-01-01

    Presents an activity that employs movement to enable students to understand concepts related to plate tectonics. Argues that movement brings topics to life in a concrete way and helps children retain knowledge. (DDR)

  19. Designing Assemblies Of Plates

    NASA Technical Reports Server (NTRS)

    Williams, F. W.; Kennedy, D.; Butler, R.; Aston, G.; Anderson, M. S.

    1992-01-01

    VICONOPT calculates vibrations and instabilities of assemblies of prismatic plates. Designed for efficient, accurate analysis of buckling and vibration, and for optimum design of panels of composite materials. Written in FORTRAN 77.

  20. Flat plate solar oven

    SciTech Connect

    Parikh, M.

    1981-01-01

    The construction of an Indian Rs. 186 (US $20.33) flat-plate solar oven is described. Detailed drawings are provided and relevant information on cooking times and temperature for different foods is given.

  1. Congruency of scapula locking plates: implications for implant design.

    PubMed

    Park, Andrew Y; DiStefano, James G; Nguyen, Thuc-Quyen; Buckley, Jenni M; Montgomery, William H; Grimsrud, Chris D

    2012-04-01

    We conducted a study to evaluate the congruency of fit of current scapular plate designs. Three-dimensional image-processing and -analysis software, and computed tomography scans of 12 cadaveric scapulae were used to generate 3 measurements: mean distance from plate to bone, maximum distance, and percentage of plate surface within 2 mm of bone. These measurements were used to quantify congruency. The scapular spine plate had the most congruent fit in all 3 measured variables. The lateral border and glenoid plates performed statistically as well as the scapular spine plate in at least 1 of the measured variables. The medial border plate had the least optimal measurements in all 3 variables. With locking-plate technology used in a wide variety of anatomical locations, the locking scapula plate system can allow for a fixed-angle construct in this region. Our study results showed that the scapular spine, glenoid, and lateral border plates are adequate in terms of congruency. However, design improvements may be necessary for the medial border plate. In addition, we describe a novel method for quantifying hardware congruency, a method that can be applied to any anatomical location.

  2. Quantitative morphometric study of the subaxial cervical vertebrae end plate.

    PubMed

    Feng, Hang; Fang, Xiangyi; Huang, Dageng; Yu, Chengcheng; Zhao, Songchuan; Hao, Dingjun

    2017-02-01

    Cervical disc arthroplasty has been gradually adopted as an alternative for the treatment of cervical degenerative disease. However, there is a large discrepancy between footprints of currently available cervical disc prostheses and anatomic dimensions of cervical end plates. This study aimed to accurately and comprehensively quantify the three-dimensional (3D) anatomic morphology of the cervical vertebral end plate and provide a theoretical basis for designing appropriate disc prostheses. Moreover, we introduced a novel geometric and mechanical model for 3D reconstruction techniques of the cervical end plate. A descriptive study of the geometry of the middle and lower cervical vertebral end plates in cadaveric spines was carried out. A total of 138 cervical vertebral end plates were digitized using an optical 3D range scanning system, and then each end plate was reconstructed using the digitized image. For each end plate, the morphologic characteristics of six surface curves and the end plate concavity depth were symmetrically chosen and depicted. The cranial end plates (relative to the disc) were concave and the caudal end plates were relatively flat at all disc levels, with mean concavity depths of 2.04 and 0.69 mm, respectively. For the caudal end plates, the end plate concavity apex was most often (81.42%) located in the posterior portion, whereas in the cranial end plates, the distribution was relatively even. For the sagittal curves, the foremost point and the rearmost point on the middle curve had a more forward position than those in the left curve and the right curve. Regarding the frontal plane curves, the length of the middle curve was longer than that of the anterior curve and posterior curve. For the cranial end plate, the maximal mean depth was the middle curve, whereas for the caudal end plate, the maximum depth was the posterior curve. There is marked morphologic asymmetry, in that the cranial end plate is more concave than the corresponding

  3. Quantitative assessment of growth plate activity

    SciTech Connect

    Harcke, H.T.; Macy, N.J.; Mandell, G.A.; MacEwen, G.D.

    1984-01-01

    In the immature skeleton the physis or growth plate is the area of bone least able to withstand external forces and is therefore prone to trauma. Such trauma often leads to premature closure of the plate and results in limb shortening and/or angular deformity (varus or valgus). Active localization of bone seeking tracers in the physis makes bone scintigraphy an excellent method for assessing growth plate physiology. To be most effective, however, physeal activity should be quantified so that serial evaluations are accurate and comparable. The authors have developed a quantitative method for assessing physeal activity and have applied it ot the hip and knee. Using computer acquired pinhole images of the abnormal and contralateral normal joints, ten regions of interest are placed at key locations around each joint and comparative ratios are generated to form a growth plate profile. The ratios compare segmental physeal activity to total growth plate activity on both ipsilateral and contralateral sides and to adjacent bone. In 25 patients, ages 2 to 15 years, with angular deformities of the legs secondary to trauma, Blount's disease, and Perthes disease, this technique is able to differentiate abnormal segmental physeal activity. This is important since plate closure does not usually occur uniformly across the physis. The technique may permit the use of scintigraphy in the prediction of early closure through the quantitative analysis of serial studies.

  4. Benchmark for license plate character segmentation

    NASA Astrophysics Data System (ADS)

    Gonçalves, Gabriel Resende; da Silva, Sirlene Pio Gomes; Menotti, David; Shwartz, William Robson

    2016-09-01

    Automatic license plate recognition (ALPR) has been the focus of many researches in the past years. In general, ALPR is divided into the following problems: detection of on-track vehicles, license plate detection, segmentation of license plate characters, and optical character recognition (OCR). Even though commercial solutions are available for controlled acquisition conditions, e.g., the entrance of a parking lot, ALPR is still an open problem when dealing with data acquired from uncontrolled environments, such as roads and highways when relying only on imaging sensors. Due to the multiple orientations and scales of the license plates captured by the camera, a very challenging task of the ALPR is the license plate character segmentation (LPCS) step, because its effectiveness is required to be (near) optimal to achieve a high recognition rate by the OCR. To tackle the LPCS problem, this work proposes a benchmark composed of a dataset designed to focus specifically on the character segmentation step of the ALPR within an evaluation protocol. Furthermore, we propose the Jaccard-centroid coefficient, an evaluation measure more suitable than the Jaccard coefficient regarding the location of the bounding box within the ground-truth annotation. The dataset is composed of 2000 Brazilian license plates consisting of 14000 alphanumeric symbols and their corresponding bounding box annotations. We also present a straightforward approach to perform LPCS efficiently. Finally, we provide an experimental evaluation for the dataset based on five LPCS approaches and demonstrate the importance of character segmentation for achieving an accurate OCR.

  5. Spirit Says Goodbye to 'Home Plate'

    NASA Technical Reports Server (NTRS)

    2006-01-01

    For the past several weeks, Spirit has been examining spectacular layered rocks exposed at 'Home Plate.' The rover has been driving around the northern and eastern edges of Home Plate, on the way to 'McCool Hill.' Before departing, Spirit took this image showing some of the most complex layering patterns seen so far at this location.

    The layered nature of these rocks presents new questions for the rover team. In addition to their chemical properties, which scientists can study using Spirit's spectrometers, these rocks record a detailed history of the physical properties that formed them. In the center of this image, one group of layers slopes downward to the right. The layers above and below this group are more nearly horizontal. Where layers of different orientations intersect, other layers are truncated. This indicates that there were complex patterns of alternating erosion and deposition occurring when these layers were being deposited. Similar patterns can be found in some sedimentary rocks on Earth. Physical relationships among the various layers exposed at Home Plate are crucial evidence in understanding how these Martian rocks formed. Scientists suspect that the rocks at Home Plate were formed in the aftermath of a volcanic explosion or impact event, and they are investigating the possibility that wind may also have played a role in redistributing materials after such an event.

    Images like this one from panoramic camera (Pancam), which shows larger-scale layering, as well as those from the microscopic imager, which reveal the individual sand-sized grains that make up these rocks, are essential to understanding the geologic history of Home Plate.

    This view is an approximately true-color rendering that combines separate images taken through the Pancam's 753-nanometer, 535-namometer, and 432-nanometer filters during Spirit's 774th Martian day (March 8, 2006).

  6. Spirit Says Goodbye to 'Home Plate'

    NASA Technical Reports Server (NTRS)

    2006-01-01

    For the past several weeks, Spirit has been examining spectacular layered rocks exposed at 'Home Plate.' The rover has been driving around the northern and eastern edges of Home Plate, on the way to 'McCool Hill.' Before departing, Spirit took this image showing some of the most complex layering patterns seen so far at this location.

    The layered nature of these rocks presents new questions for the rover team. In addition to their chemical properties, which scientists can study using Spirit's spectrometers, these rocks record a detailed history of the physical properties that formed them. In the center of this image, one group of layers slopes downward to the right. The layers above and below this group are more nearly horizontal. Where layers of different orientations intersect, other layers are truncated. This indicates that there were complex patterns of alternating erosion and deposition occurring when these layers were being deposited. Similar patterns can be found in some sedimentary rocks on Earth. Physical relationships among the various layers exposed at Home Plate are crucial evidence in understanding how these Martian rocks formed. Scientists suspect that the rocks at Home Plate were formed in the aftermath of a volcanic explosion or impact event, and they are investigating the possibility that wind may also have played a role in redistributing materials after such an event.

    Images like this one from panoramic camera (Pancam), which shows larger-scale layering, as well as those from the microscopic imager, which reveal the individual sand-sized grains that make up these rocks, are essential to understanding the geologic history of Home Plate.

    This view is an approximately true-color rendering that combines separate images taken through the Pancam's 753-nanometer, 535-namometer, and 432-nanometer filters during Spirit's 774th Martian day (March 8, 2006).

  7. Positive battery plate

    NASA Technical Reports Server (NTRS)

    Rowlette, John R. (Inventor)

    1985-01-01

    The power characteristics of a lead acid battery are improved by incorporating a dispersion of 1 to 10% by weight of a thermodynamically stable conductivity additive, such as conductive tin oxide coated glass fibers (34) of filamentary glass wool (42) in the positive active layer (32) carried on the grid (30) of the positive plate (16). Positive plate potential must be kept high enough to prevent reduction of the tin oxide to tin by utilizing an oversized, precharged positive paste.

  8. Fractal multifiber microchannel plates

    NASA Technical Reports Server (NTRS)

    Cook, Lee M.; Feller, W. B.; Kenter, Almus T.; Chappell, Jon H.

    1992-01-01

    The construction and performance of microchannel plates (MCPs) made using fractal tiling mehtods are reviewed. MCPs with 40 mm active areas having near-perfect channel ordering were produced. These plates demonstrated electrical performance characteristics equivalent to conventionally constructed MCPs. These apparently are the first MCPs which have a sufficiently high degree of order to permit single channel addressability. Potential applications for these devices and the prospects for further development are discussed.

  9. Future earthquake source faults on deep sea-floor around the Boso triple plate junction revealed by tectonic geomorphology using 3D images produced from 150 meter grid DEM

    NASA Astrophysics Data System (ADS)

    Goto, H.; Nakata, T.; Watanabe, M.; Suzuki, Y.; Izumi, N.; Nishizawa, A.; Horiuchi, D.; Kido, Y. N.

    2013-12-01

    Boso triple junction, which is the only example of a triple trench junction on earth, is located off the southeast of Boso peninsula, where the Izu-Bonin trench meets with the Japan trench and the Sagami trench. Boso submarine canyon, which is extended to Katsuuma basin about 7000m deep, forms an incised meander along the north side of Sagami trough. Taito spur separate Katsuuma basin from Bando abyssal basin about 9000m deep, where Japan trench meet with Isu-Bonin trench. In this paper, we present detailed stereo-paired topographic images produced from 0.002 degree (about 150m) DBEM (Digital Bathymetry Model), which processed from the depth sounding data obtained by Japan Coast Guard and JAMSTEC around Boso triple junction. It enables us to observe submarine geomorphology easily and precisely. We identified submarine active faults and other tectonic features related to subduction by using the similar standard for air-photo interpretation of inland active faults. We made more precise submarine active tectonic geomorphological map around Boso triple junction than that by previous workers. Numerous distinct faults on the so-called outer rise associated with subduction of Pacific plate are regarded as normal faulting as widely accepted. While the normal faults on the outer rise are parallel to the trench in the southern part of the Japan trench and the northern part of the Izu-Bonin trench, these normal faults around the east of the triple junction with NNW-SSE extend slightly oblique to the trench. The western margin of Bando abyssal basin is bounded by the thrust faults, which form east-facing 200-500m-high convex scarps associated with raised basin floor to the west of the scarp. These faults also deform Mogi submarine fan surface and uplift to the west along the extension of the scarp. The antecedent valley is extended for about 10km across Taito spur that is an active anticlinal ridge about 1000m high. Katsuura basin is surrounded by terraced former basin floor

  10. Reconstructing Plate Motions on Europa with GPlates

    NASA Astrophysics Data System (ADS)

    Cutler, B. B.; Collins, G. C.; Prockter, L. M.; Patterson, G.; Kattenhorn, S. A.; Rhoden, A.; Cooper, C. M.

    2015-12-01

    Observations of past plate tectonic - like motions in Europa's icy lithosphere have been reported in previous studies. Quantifying the nature, age, and amount of plate motion is important for geophysical models of Europa's ice shell and for astrobiology, since subsumed pates could drive the flow of nutrients into the subsurface ocean. We have used GPlates software (Williams et al., GSA Today 2012) and a mosaic of regional-resolution Galileo SSI data from orbits E11, E15, E17, and E19 to make interactive reconstructions of both the Northern Falga region (60N, 220W) and the Castalia Macula region (0N, 225W). The advantage of this method is that plate motions are calculated on a sphere, while still maintaining the original Galileo image pieces in their proper geographic locations. Previous work on the Castalia Macula region (Patterson et al. J.Struct.Geol. 2006) and the adjacent Phaidra Linea region (Patterson and Ernst, LPSC 2011) found offsets along spreading boundaries, and then calculated the best fit finite rotations to close those offsets. Though this method is mathematically rigorous and gives a statistical goodness of fit, it is not easy to test multiple hypotheses for candidate piercing points or divisions of candidate plate boundaries. Through the interactive environment, we found that we could better account for observed offsets in this region by breaking it into 32 different plates. Patterson and Ernst broke the Phaidra region into 6 plates which exhibited nonrigid behavior, where our study breaks it into 16 rigid plates. The Northern Falga Regio area is interesting due to the potential for large amounts of subsumption of Europa's icy crust in this location. The previous reconstruction (Kattenhorn and Prockter, Nat.Geosci. 2014) was based on planar geometry, and we have replicated these results using a spherically-based reconstruction. We will present the plate maps and reconstructions for both of these regions, along with the best fit rotation poles.

  11. Critical range evaluation using a diagonal flat plate

    NASA Technical Reports Server (NTRS)

    Lee, Teh-Hong; Clark, Tony L.; Burnside, Walter D.; Gupta, Inder J.

    1992-01-01

    A novel technique is presented to image stray signals in RCS measurement ranges. In this technique, the scattered fields of a flat plate in the diagonal plane are measured in a range for various frequencies and look angles. The scattered field data is then processed to generate an inverse synthetic aperture radar (ISAR) image of the diagonal flat plate. It is shown that scattering mechanisms associated with various stray signals can be identified by using the ISAR image. This leads to better understanding of the range and possible chamber improvements. Scattering mechanisms as small as 90 dB below the plate broadside scattered field level have been observed in the image domain due to the high directivity and low sidelobe characteristics associated with the diagonal flat plate backscattered fields. The results obtained from evaluating the two compact range facilities at The Ohio State University ElectroScience Laboratory are presented to illustrate the virtues of this new range evaluation technique.

  12. Influence of hydration and annealing on structure, PSL yield and spatial resolution of pressed powder imaging plates of the X-ray storage phosphor CsBr:Eu2+

    NASA Astrophysics Data System (ADS)

    Kersting, E.; von Seggern, H.

    2017-08-01

    A new production route for europium doped cesium bromide (CsBr:Eu2+) imaging plates has been developed, synthesizing CsBr:Eu2+ powder from a precipitation reaction of aqueous CsBr solution with ethanol. This new route allows the control of features like homogeneous grain size and grain shape of the obtained powder. After drying and subsequent compacting the powder, disk-like samples were fabricated, and their resulting photostimulated luminescence (PSL) properties like yield and spatial resolution were determined. It will be shown that hydration of such disks causes the CsBr:Eu2+ powder to recrystallize starting from the humidity exposed surfaces to the sample interior up to a completely polycrystalline sample resulting in a decreasing PSL yield and an increasing resolution. Subsequent annealing leads to grain refinement combined with a large PSL yield increment and a minor effect on the spatial resolution. By first annealing the "as made" disk, one observes a strong increment of the PSL yield and almost no effect on the spatial resolution. During subsequent hydration, the recrystallization is hindered by minor structural changes of the grains. The related PSL yield drops slightly with increasing hydration time, and the spatial resolution drops considerably. The obtained PSL properties with respect to structure will be discussed with a simple model.

  13. Validation of modelled imaging plates sensitivity to 1-100 keV x-rays and spatial resolution characterisation for diagnostics for the “PETawatt Aquitaine Laser”

    SciTech Connect

    Boutoux, G. Batani, D.; Burgy, F.; Ducret, J.-E.; Forestier-Colleoni, P.; Hulin, S.; Rabhi, N.; Duval, A.; Lecherbourg, L.; Reverdin, C.; Jakubowska, K.; Szabo, C. I.; Bastiani-Ceccotti, S.; Consoli, F.; Curcio, A.; De Angelis, R.; Ingenito, F.; Baggio, J.; Raffestin, D.

    2016-04-15

    Thanks to their high dynamic range and ability to withstand electromagnetic pulse, imaging plates (IPs) are commonly used as passive detectors in laser-plasma experiments. In the framework of the development of the diagnostics for the Petawatt Aquitaine Laser facility, we present an absolute calibration and spatial resolution study of five different available types of IP (namely, MS-SR-TR-MP-ND) performed by using laser-induced K-shell X-rays emitted by a solid silver target irradiated by the laser ECLIPSE at CEntre Lasers Intenses et Applications. In addition, IP sensitivity measurements were performed with a 160 kV X-ray generator at CEA DAM DIF, where the absolute response of IP SR and TR has been calibrated to X-rays in the energy range 8-75 keV with uncertainties of about 15%. Finally, the response functions have been modeled in Monte Carlo GEANT4 simulations in order to reproduce experimental data. Simulations enable extrapolation of the IP response functions to photon energies from 1 keV to 1 GeV, of interest, e.g., for laser-driven radiography.

  14. Simple biosensor with high selectivity and sensitivity: thiol-specific biomolecular probing and intracellular imaging by AIE fluorogen on a TLC plate through a thiol-ene click mechanism.

    PubMed

    Liu, Yang; Yu, Yong; Lam, Jacky W Y; Hong, Yuning; Faisal, Mahtab; Yuan, Wang Zhang; Tang, Ben Zhong

    2010-07-26

    A handy, specific, sensitive bioprobe has been developed. Tetraphenylethene (TPE) was functionalized by a maleimide (MI) group, giving a TPE-MI adduct that was nonemissive in both solution and the solid state. It was readily transformed into a fluorogen showing an aggregation-induced emission (AIE) property by the click addition of thiol to its MI pendant. The click reaction and the AIE effect enabled TPE-MI to function as a thiol-specific bioprobe in the solid state. Thus, the spot of TPE-MI on a TLC plate became emissive when it had been exposed to L-cysteine, an amino acid containing a thiol group, but remained nonemissive when exposed to other amino acids that lack free thiol units. The thiol-activated emission was rapid and strong, readily detected by the naked eye at an analyte concentration as low as approximately 1 ppb, thanks to the "lighting up" nature of the bioprobing process. Similarly, the emission of TPE-MI was turned on only by the proteins containing free thiol units, such as glutathione. Clear fluorescence images were taken when living cells were stained by using TPE-MI as a visualization agent, affording a facile fluorescent maker for mapping the distribution of thiol species in cellular systems.

  15. Ponderomotive phase plate for transmission electron microscopes

    DOEpatents

    Reed, Bryan W [Livermore, CA

    2012-07-10

    A ponderomotive phase plate system and method for controllably producing highly tunable phase contrast transfer functions in a transmission electron microscope (TEM) for high resolution and biological phase contrast imaging. The system and method includes a laser source and a beam transport system to produce a focused laser crossover as a phase plate, so that a ponderomotive potential of the focused laser crossover produces a scattering-angle-dependent phase shift in the electrons of the post-sample electron beam corresponding to a desired phase contrast transfer function.

  16. Spirit's Tracks around 'Home Plate'

    NASA Technical Reports Server (NTRS)

    2006-01-01

    [figure removed for brevity, see original site] Annotated Version

    This portion of an image acquired by the Mars Reconnaissance Orbiter's High Resolution Imaging Science Experiment camera shows the Spirit rover's winter campaign site. The rover is visible. So is the 'Low Ridge' feature where Spirit was parked with an 11-degree northerly tilt to maximize sunlight on the solar panels during the southern winter season. Tracks made by Spirit on the way to 'Home Plate' and to and from 'Tyrone,' an area of light-toned soils exposed by rover wheel motions, are also evident. The original image is catalogued as PSP_001513_1655_red and was taken Sept. 29, 2006.

    NASA's Jet Propulsion Laboratory, a division of the California Institute of Technology in Pasadena, manages the Mars Reconnaissance Orbiter for NASA's Science Mission Directorate, Washington. Lockheed Martin Space Systems, Denver, is the prime contractor for the project and built the spacecraft. The High Resolution Imaging Science Experiment is operated by the University of Arizona, Tucson, and the instrument was built by Ball Aerospace and Technology Corp., Boulder, Colo.

  17. Spirit's Tracks around 'Home Plate'

    NASA Technical Reports Server (NTRS)

    2006-01-01

    [figure removed for brevity, see original site] Annotated Version

    This portion of an image acquired by the Mars Reconnaissance Orbiter's High Resolution Imaging Science Experiment camera shows the Spirit rover's winter campaign site. The rover is visible. So is the 'Low Ridge' feature where Spirit was parked with an 11-degree northerly tilt to maximize sunlight on the solar panels during the southern winter season. Tracks made by Spirit on the way to 'Home Plate' and to and from 'Tyrone,' an area of light-toned soils exposed by rover wheel motions, are also evident. The original image is catalogued as PSP_001513_1655_red and was taken Sept. 29, 2006.

    NASA's Jet Propulsion Laboratory, a division of the California Institute of Technology in Pasadena, manages the Mars Reconnaissance Orbiter for NASA's Science Mission Directorate, Washington. Lockheed Martin Space Systems, Denver, is the prime contractor for the project and built the spacecraft. The High Resolution Imaging Science Experiment is operated by the University of Arizona, Tucson, and the instrument was built by Ball Aerospace and Technology Corp., Boulder, Colo.

  18. Caribbean plate interactions

    SciTech Connect

    Ball, M. )

    1993-02-01

    Vector analysis of plate motions, derived from studies of Atlantic magnetic lineations and fracture zone trends, indicates the following relative movements between the Caribbean, North American, and South American Plates. (1) During Early Jurassic to Early Cretaceous, the North American Plate moved 1900 km westward and 900 km northward relative to the South American Plate. A broad zone including the Caribbean region, i.e., the zone between the North and South America Plates, was a site of left-lateral shear and north-south extension. (2) During Early Cretaceous to Late Cretaceous, the North American Mate moved an additional 1200 km westward relative to South America across this zone. (3) During Late Cretaceous to the end of the Eocene, the North American Plate moved 200 km westward and 400 km northward relative to the South American Plate. (4) From the end of the Eocene to near the end of the Miocene, North America converged on South America some 200 km and moved 100 km eastward relative to it. Through the Mesozoic and earliest Tertiary history of the Caribbean, the region was a shear zone within which left-lateral displacement exceeded 3000 km and north-south extension exceeded 1300 km. In regard to time, 80% of the history of the Caribbean region is one of north-south extension and left-lateral shear. In terms of space, 97% of the shear is left-lateral and the ratio of divergence versus convergence is 7 to 1. Thus, characterizing the Caribbean region, and the Atlantic to its east, as a zone of north-south extension and left-lateral shear, is a fair generalization.

  19. 'Gibson' Panorama by Spirit at 'Home Plate'

    NASA Technical Reports Server (NTRS)

    2006-01-01

    [figure removed for brevity, see original site] Click on the image for 'Gibson' Panorama by Spirit at 'Home Plate' (QTVR)

    NASA's Mars Exploration Rover Spirit acquired this high-resolution view of intricately layered exposures of rock while parked on the northwest edge of the bright, semi-circular feature known as 'Home Plate.' The rover was perched at a 27-degree upward tilt while creating the panorama, resulting in the 'U' shape of the mosaic. In reality, the features along the 1-meter to 2-meter (1-foot to 6.5-foot) vertical exposure of the rim of Home Plate in this vicinity are relatively level. Rocks near the rover in this view, known as the 'Gibson' panorama, include 'Barnhill,' 'Rogan,' and 'Mackey.'

    Spirit acquired 246 separate images of this scene using 6 different filters on the panoramic camera (Pancam) during the rover's Martian days, or sols, 748 through 751 (Feb. 9 through Feb. 12, 2006). The field of view covers 160 degrees of terrain around the rover. This image is an approximately true-color rendering using Pancam's 753-nanometer, 535-namometer, and 432-nanometer filters. Image-to-image seams have been eliminated from the sky portion of the mosaic to better simulate the vista a person standing on Mars would see.

  20. 'Gibson' Panorama by Spirit at 'Home Plate'

    NASA Technical Reports Server (NTRS)

    2006-01-01

    [figure removed for brevity, see original site] Click on the image for 'Gibson' Panorama by Spirit at 'Home Plate' (QTVR)

    NASA's Mars Exploration Rover Spirit acquired this high-resolution view of intricately layered exposures of rock while parked on the northwest edge of the bright, semi-circular feature known as 'Home Plate.' The rover was perched at a 27-degree upward tilt while creating the panorama, resulting in the 'U' shape of the mosaic. In reality, the features along the 1-meter to 2-meter (1-foot to 6.5-foot) vertical exposure of the rim of Home Plate in this vicinity are relatively level. Rocks near the rover in this view, known as the 'Gibson' panorama, include 'Barnhill,' 'Rogan,' and 'Mackey.'

    Spirit acquired 246 separate images of this scene using 6 different filters on the panoramic camera (Pancam) during the rover's Martian days, or sols, 748 through 751 (Feb. 9 through Feb. 12, 2006). The field of view covers 160 degrees of terrain around the rover. This image is an approximately true-color rendering using Pancam's 753-nanometer, 535-namometer, and 432-nanometer filters. Image-to-image seams have been eliminated from the sky portion of the mosaic to better simulate the vista a person standing on Mars would see.

  1. Accuracy of distal radius positioning using an anatomical plate.

    PubMed

    Vroemen, Joy C; Dobbe, Johannes G G; Sierevelt, Inger N; Strackee, Simon D; Streekstra, Geert J

    2013-04-01

    Over the past decade, several anatomical plates have been introduced to improve the result of open reduction and internal fixation of the distal radius. Using 3-dimensional imaging techniques, the authors studied the accuracy and reproducibility of distal radius positioning using anatomical plates.Distal radius fractures and the correction of these fractures were simulated with plastic bone models of radii. The authors simulated a defect by removing an arbitrary wedge shape from the artificial radii. Two surgeons corrected these fractures by placing 2 anatomical plate types according to the plate manufacturers' instructions. The residual positioning errors of the distal segment in relation to the unaffected radii were determined using 3-dimensional imaging and were compared with naturally occurring bilateral radius differences in healthy individuals. In many cases, positioning does not agree with differences based on bilateral asymmetry in healthy patients.This study indicated the accuracy of anatomical plates. Positioning an anatomical plate may lead to considerable residual errors in individual patients. Volar distal radius plate shapes differ among plate manufacturers. Therefore, one plate may perform better than another in an individual.

  2. The stepped hybrid plate for carpal panarthrodesis - Part I: relationship between plate and bone surfaces.

    PubMed

    Diaz-Bertrana, C; Darnaculleta, F; Durall, I; Franch, J; Puchol, J L

    2009-01-01

    In the 1990s, the AO (Arbeitsgemeinschaft für Osteosynthesefragen) Hand Study Group developed several anatomically bent plates (standard and short) for wrist panarthrodesis in humans. However, only straight plates have been used for carpal panarthrodesis (CP) in animals to date. The primary purpose of this study was to determine if precontoured plates are more anatomical for CP in dogs. Measurement of several of the bones that are implicated in CP, as well as the relationship between their surfaces and the surface of a straight plate, were performed in a radiographic and computed tomographic cadaveric study. Axial and transverse measurements taken at different levels of the metacarpal bones 2, 3 and 4 were also included. The second objective of this study was to develop a more anatomical CP plate according to the results obtained. The measurements and images obtained in this study show that, as in human orthopaedics, bent or stepped plates are more anatomically correct than straight plates for CP in dogs.

  3. Ishihara color plates as a test for simultanagnosia.

    PubMed

    Brazis, P W; Graff-Radford, N R; Newman, N J; Lee, A G

    1998-12-01

    To alert ophthalmologists to the use of Ishihara color plates in the detection of simultanagnosia. We examined seven patients referred for impaired vision. Evaluation included color plate testing with Ishihara color plates. All seven patients had simultanagnosia, with marked difficulty in identifying the numbers in Ishihara color plates despite adequate visual acuity and the ability to name all of the colors in the plates correctly. One of these patients was referred with the diagnosis of a cone dystrophy because of her poor performance on the Ishihara test. All of the patients had bilateral occipitoparietal damage or atrophy on magnetic resonance imaging. Ophthalmologists must be aware that a poor performance with Ishihara plates may not be attributable to an impairment of color vision but rather to occipitoparietal brain damage associated with simultanagnosia.

  4. A unidirectional subwavelength focusing near-field plate

    SciTech Connect

    Imani, Mohammadreza F.; Grbic, Anthony

    2014-01-28

    Near-field plates consist of non-periodically patterned surfaces that can overcome the diffraction limit and confine electromagnetic fields to subwavelength dimensions. Previous near-field plates experimentally demonstrated extreme field tailoring capabilities. However, their performance suffered from radiation/reflection in undesired directions, those other than the subwavelength focus. This issue can limit the practical use of near-field plates. In this paper, we address this issue by designing a unidirectional near-field plate that can form a subwavelength focal pattern, while suppressing the field radiated/reflected in other directions. The design and operation of the proposed unidirectional near-field plate are verified through full-wave simulation. The unidirectional near-field plate may find application in high resolution imaging and probing, high density data storage, and wireless power transfer systems. As an example, its utility as a high resolution probe is demonstrated through full-wave electromagnetic simulation.

  5. Wide-field plate archives in Rozhen and Belgrade observatories.

    NASA Astrophysics Data System (ADS)

    Tsvetkova, Katya; Tsvetkov, Milcho; Dimitrijević, Milan S.; Protić-Benišek, Vojislava; Benišek, Vladimir; Jevremović, Darko

    The wide-field plate archives at disposal in Rozhen Observatory (9332 plates obtained in the period 1979 - 1994) and Belgrade Observatory (14500 plates obtained in the period 1936 - 1996) are presented. The plate archives, made in the frames of different observing programmes, reflect the tendencies in the development of astronomy in these countries. The results from the joint collaboration concerning the plate cataloguing and digitization with EPSON flatbed scanners providing good speed of scanning and good astrometric and photometric accuracy while generating digital data, as well as the inclusion of the images of the scanned plates in WFPDB and BELDATA and their online access in the frames of the Virtual Observatory, are presented too.

  6. Cadmium plating replacements

    NASA Technical Reports Server (NTRS)

    Nelson, Mary J.; Groshart, Earl C.

    1995-01-01

    The Boeing Company has been searching for replacements to cadmium plate. Two alloy plating systems seem close to meeting the needs of a cadmium replacement. The two alloys, zinc-nickel and tin-zinc are from alloy plating baths; both baths are neutral pH. The alloys meet the requirements for salt fog corrosion resistance, and both alloys excel as a paint base. Currently, tests are being performed on standard fasteners to compare zinc-nickel and tin-zinc on threaded hardware where cadmium is heavily used. The Hydrogen embrittlement propensity of the zinc-nickel bath has been tested, and just beginning for the tin-zinc bath. Another area of interest is the electrical properties on aluminum for tin-zinc and will be discussed. The zinc-nickel alloy plating bath is in production in Boeing Commercial Airplane Group for non-critical low strength steels. The outlook is promising that these two coatings will help The Boeing Company significantly reduce its dependence on cadmium plating.

  7. Cadmium plating replacements

    SciTech Connect

    Nelson, M.J.; Groshart, E.C.

    1995-03-01

    The Boeing Company has been searching for replacements to cadmium plate. Two alloy plating systems seem close to meeting the needs of a cadmium replacement. The two alloys, zinc-nickel and tin-zinc are from alloy plating baths; both baths are neutral pH. The alloys meet the requirements for salt fog corrosion resistance, and both alloys excel as a paint base. Currently, tests are being performed on standard fasteners to compare zinc-nickel and tin-zinc on threaded hardware where cadmium is heavily used. The Hydrogen embrittlement propensity of the zinc-nickel bath has been tested, and just beginning for the tin-zinc bath. Another area of interest is the electrical properties on aluminum for tin-zinc and will be discussed. The zinc-nickel alloy plating bath is in production in Boeing Commercial Airplane Group for non-critical low strength steels. The outlook is promising that these two coatings will help The Boeing Company significantly reduce its dependence on cadmium plating.

  8. A Robust and Efficient Approach to License Plate Detection.

    PubMed

    Yuan, Yule; Zou, Wenbin; Zhao, Yong; Wang, Xinan; Hu, Xuefeng; Komodakis, Nikos

    2017-03-01

    This paper presents a robust and efficient method for license plate detection with the purpose of accurately localizing vehicle license plates from complex scenes in real time. A simple yet effective image downscaling method is first proposed to substantially accelerate license plate localization without sacrificing detection performance compared with that achieved using the original image. Furthermore, a novel line density filter approach is proposed to extract candidate regions, thereby significantly reducing the area to be analyzed for license plate localization. Moreover, a cascaded license plate classifier based on linear support vector machines using color saliency features is introduced to identify the true license plate from among the candidate regions. For performance evaluation, a data set consisting of 3977 images captured from diverse scenes under different conditions is also presented. Extensive experiments on the widely used Caltech license plate data set and our newly introduced data set demonstrate that the proposed approach substantially outperforms state-of-the-art methods in terms of both detection accuracy and run-time efficiency, increasing the detection ratio from 91.09% to 96.62% while decreasing the run time from 672 to 42 ms for processing an image with a resolution of 1082×728 . The executable code and our collected data set are publicly available.

  9. Radiation imaging system

    DOEpatents

    Immel, David M.; Bobbit, III, John T.; Plummer, Jean R.; Folsom, Matthew D.; Serrato, Michael G.

    2016-03-22

    A radiation imaging system includes a casing and a camera disposed inside the casing. A first field of view through the casing exposes the camera to light from outside of the casing. An image plate is disposed inside the casing, and a second field of view through the casing to the image plate exposes the image plate to high-energy particles produced by a radioisotope outside of the casing. An optical reflector that is substantially transparent to the high-energy particles produced by the radioisotope is disposed with respect to the camera and the image plate to reflect light to the camera and to allow the high-energy particles produced by the radioisotope to pass through the optical reflector to the image plate.

  10. Radiation imaging system

    DOEpatents

    Bobbitt, III, John T.; Immel, David M.; Folsom, Matthew D.; Plummer, Jean R.; Serrato, Michael G.

    2016-06-28

    A radiation imaging system includes a casing and a camera disposed inside the casing. A first field of view through the casing exposes the camera to light from outside of the casing. An image plate is disposed inside the casing, and a second field of view through the casing to the image plate exposes the image plate to high-energy particles produced by a radioisotope outside of the casing. An optical reflector that is substantially transparent to the high-energy particles produced by the radioisotope is disposed with respect to the camera and the image plate to reflect light to the camera and to allow the high-energy particles produced by the radioisotope to pass through the optical reflector to the image plate.

  11. Bipolar battery plate

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor)

    1987-01-01

    A liquid-impermeable plate (10) having through-plate conductivity with essentially zero resistance comprises an insulator sheet (12) having a series of spaced perforations (14) each of which contains a metal element (16) sealingly received into the perforation (14). A low-cost plate can readily be manufactured by punching a thermoplastic sheet (40) such as polypropylene with a punching tool (52), filling the apertures with led spheres (63) having a diameter smaller than the holes (50) but larger than the thickness of the sheet, sweeping excess spheres (62) off the sheet with a doctor blade (60) and then pressing a heated platen (74) onto the sheet to swage the spheres into a cylindrical shape and melt the surrounding resin to form a liquid-impermeable collar (4) sealing the metal into the sheet.

  12. Effect of nozzle-to-plate spacing on the development of a plane jet impinging on a heated plate

    NASA Astrophysics Data System (ADS)

    Rim, Ben Kalifa; Saïd, Nejla Mahjoub; Bournot, Hervé; Le Palec, Georges

    2017-04-01

    An experimental investigation was carried out to study the behavior of a turbulent air jet impinging on a heated plate. The study of the flow field was performed using a particle image velocimetry. A three-dimensional numerical model with Reynolds stress model has been conducted to examine the global flow. Numerical results agree well with experimental data. The main properties of the fluid occurring between the nozzle and the flat plate are presented. In addition, the effect of the distance between the nozzle exit and the plate (h/e = 14 and 28) were investigated and detailed analysis of the dynamic, turbulent distribution and temperature fields were performed. The wall shear stress and the pressure fields near the heated plate are then explored. Results showed that the mean velocity and the heat transfer characteristics of small nozzle-to-plate spacing are significantly different from those of large nozzle-to-plate spacing.

  13. Effect of nozzle-to-plate spacing on the development of a plane jet impinging on a heated plate

    NASA Astrophysics Data System (ADS)

    Rim, Ben Kalifa; Saïd, Nejla Mahjoub; Bournot, Hervé; Le Palec, Georges

    2016-09-01

    An experimental investigation was carried out to study the behavior of a turbulent air jet impinging on a heated plate. The study of the flow field was performed using a particle image velocimetry. A three-dimensional numerical model with Reynolds stress model has been conducted to examine the global flow. Numerical results agree well with experimental data. The main properties of the fluid occurring between the nozzle and the flat plate are presented. In addition, the effect of the distance between the nozzle exit and the plate (h/e = 14 and 28) were investigated and detailed analysis of the dynamic, turbulent distribution and temperature fields were performed. The wall shear stress and the pressure fields near the heated plate are then explored. Results showed that the mean velocity and the heat transfer characteristics of small nozzle-to-plate spacing are significantly different from those of large nozzle-to-plate spacing.

  14. Plate-mantle coupling from post-Pangea plate kinematics

    NASA Astrophysics Data System (ADS)

    Zahirovic, Sabin; Dietmar Müller, R.; Seton, Maria; Flament, Nicolas

    2015-04-01

    Convection in the Earth's mantle that involves plates at the surfaces gives rise to plate velocities that vary through time and depend on the balance of plate boundary forces, with the present-day providing a snapshot of this ongoing process. However, present-day plate velocities do not capture plate behaviour over geologically representative timeframes and thus cannot be used to evaluate factors limiting plate velocities. Previous studies investigated the effects of continental keels on plate speeds by either using the present-day snapshot or a limited number of reconstructed plate configurations, often leading to conflicting results. For example, an early assumption was that continental keels (especially cratons) were unlikely to impede fast plate motions because India's velocity approached ~20 cm/yr in the Eocene prior to the collision with Eurasia. We employ a modern plate reconstruction approach with evolving global topological plate boundaries for the post-Pangea timeframe (since 200 Ma) to evaluate factors controlling plate velocities. Plate boundary configurations and plate velocities are extracted from the open-source and cross-platform plate reconstruction package GPlates (www.gplates.org) at 1 Myr intervals. For each plate, at each timestep, the area of continental and cratonic lithosphere is calculated to evaluate the effect on plate velocities. Our results support that oceanic plates tend to be 2-3 times faster than plates with large portion of continental plate area, consistent with predictions of numerical models of mantle convection. The fastest plates (~8.5 cm/yr RMS) are dominated by oceanic plate area and high subducting portion of plate perimeter, while the slowest plates (~2.6-2.8 cm/yr RMS) are dominated by continental plate area and bounded by transforms and mid-oceanic ridge segments. Importantly, increasing cratonic fractions (both Proterozoic and Archean lithosphere) significantly impede plate velocities, suggesting that deep continental

  15. Nitrided Metallic Bipolar Plates

    SciTech Connect

    Brady, Michael P; Tortorelli, Peter F; Pihl, Josh A; Toops, Todd J; More, Karren Leslie; Meyer III, Harry M; Vitek, John Michael; Wang, Heli; Turner, John; Wilson, Mahlon; Garzon, Fernando; Rockward, Tommy; Connors, Dan; Rakowski, Jim; Gervasio, Don

    2008-01-01

    The objectives are: (1) Develop and optimize stainless steel alloys amenable to formation of a protective Cr-nitride surface by gas nitridation, at a sufficiently low cost to meet DOE targets and with sufficient ductility to permit manufacture by stamping. (2) Demonstrate capability of nitridation to yield high-quality stainless steel bipolar plates from thin stamped alloy foils (no significant stamped foil warping or embrittlement). (3) Demonstrate single-cell fuel cell performance of stamped and nitrided alloy foils equivalent to that of machined graphite plates of the same flow-field design ({approx}750-1,000 h, cyclic conditions, to include quantification of metal ion contamination of the membrane electrode assembly [MEA] and contact resistance increase attributable to the bipolar plates). (4) Demonstrate potential for adoption in automotive fuel cell stacks. Thin stamped metallic bipolar plates offer the potential for (1) significantly lower cost than currently-used machined graphite bipolar plates, (2) reduced weight/volume, and (3) better performance and amenability to high volume manufacture than developmental polymer/carbon fiber and graphite composite bipolar plates. However, most metals exhibit inadequate corrosion resistance in proton exchange membrane fuel cell (PEMFC) environments. This behavior leads to high electrical resistance due to the formation of surface oxides and/or contamination of the MEA by metallic ions, both of which can significantly degrade fuel cell performance. Metal nitrides offer electrical conductivities up to an order of magnitude greater than that of graphite and are highly corrosion resistant. Unfortunately, most conventional coating methods (for metal nitrides) are too expensive for PEMFC stack commercialization or tend to leave pinhole defects, which result in accelerated local corrosion and unacceptable performance.

  16. Reduced Plating Ignitron

    NASA Technical Reports Server (NTRS)

    Polzin, Kurt A (Inventor); Pearson, J Boise (Inventor)

    2014-01-01

    An ignitron apparatus has an airtight tubular housing having a first sealed end and a second sealed end. An anode is connected at the first sealed end, projecting into the housing, and a recess at the second sealed and forms a well which contains a quantity of liquid gallium or gallium alloy making up the cathode. An ignitor projects through the liquid metal and into the housing. The inner surface of the housing includes at least one plating-reduction structure to prevent electrical shorting of the apparatus caused by plating of the liquid metal.

  17. Plating under reduced pressure

    SciTech Connect

    Dini, J.W.; Beat, T.G.; Cowden, W.C. ); Ryan, L.E.; Hewitt, W.B. )

    1992-06-01

    Plating under reduced pressure was evaluated for both electroless nickel and electrodeposited copper systems. The objective was to reduce pitting of these coatings thereby further enhancing their usage for diamond turning applications. Cursory experiments with electroless nickel showed reduced porosity when deposition was done at around 500 torr. Detailed experiments with electrodeposited copper at around 100 torr provided similar results. Scanning tunneling microscopy was effectively used to show the improvement in the copper deposits plated under reduced pressure. Benefits included reduced surface roughness and finer and denser grain structure.

  18. NICKEL PLATING PROCESS

    DOEpatents

    Hoover, T.B.; Zava, T.E.

    1959-05-12

    A simplified process is presented for plating nickel by the vapor decomposition of nickel carbonyl. In a preferred form of the invention a solid surface is nickel plated by subjecting the surface to contact with a mixture containing by volume approximately 20% nickel carbonyl vapor, 2% hydrogen sulfide and .l% water vapor or 1% oxygen and the remainder carbon dioxide at room temperature until the desired thickness of nickel is obtained. The advantage of this composition over others is that the normally explosive nickel carbonyl is greatly stabilized.

  19. PCM Composite Cold Plate.

    DTIC Science & Technology

    1996-04-01

    packaging design for phase change materials (PCMs) used in thermal management. To control expansion stress, conventional PCM heat sinks have strong encapsulation that weighs more than the PCM they contain. The objective of this work is to develop PCM heat sinks configured as thin sandwich plates, in which the mass of the encapsulation is a small fraction of the PCM mass. The design is based on a lightweight carbon fiber core that has suitable mechanical, thermal, and capillary properties. PCM composite plates were fabricated with dimensions 15x15x0.6 cm3 and with a

  20. 77 FR 59013 - State Journal Register, Camera and Plate Department, Springfield, IL; Notice of Affirmative...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-25

    ... filed ] on behalf of ``Camera/Plate-Prepress-Imaging, Ad Srvs. & Market'' workers at State Journal... Employment and Training Administration State Journal Register, Camera and Plate Department, Springfield, IL... workers of State Journal Register, Camera and Plate Department, Springfield, Illinois. The...

  1. Intermittent Plate Tectonics

    NASA Astrophysics Data System (ADS)

    Silver, P. G.; Behn, M. D.

    2006-12-01

    Intermittent Plate Tectonics A basic premise of Earth Science is that plate tectonics has been continuously operating since it began early in Earth's history. Yet, plate-tectonic theory itself, specifically the collisional phase of the Wilson Cycle, constitutes a process that is capable of stopping all plate motion. The plausibility of a plate-tectonic hiatus is most easily illustrated by considering the expected future of the present-day plate-tectonic configuration. Since the opening of the Atlantic at ~200 ma, the area of the Atlantic basin has been growing at the expense of the Pacific. If this trend continues, relative plate motion models predict that in ~350 my, the Pacific Ocean basin will effectively close leading to widespread continent-continent collisions. Since a continent-continent collision represents the termination of subduction locally, the accumulated effect of all collisions is to stop subduction globally. In this scenario, ridges would then stop spreading and young oceanic lithosphere would cool, reaching a steady-state thickness of 100 km in about 80 my, based on the properties of oceanic lithosphere today. This would constitute the stoppage of plate tectonics. The presumption that plate tectonics never stops in the face of continental collisions is equivalent to requiring that subduction flux is approximately constant through time, such that subduction initiation roughly balances subduction termination. Such a balance then raises several questions about the subduction initiation process. When and how does subduction initiate? Is there a detectible relationship between subduction cessation and subduction initiation? We can gain some guidance into these questions by examining the plate motion history over the last 200 my. Subduction initiation has occurred over the last 80 my in three intra- oceanic subduction zones: Aleutians, Marianas-Izu-Bonin and Tonga-Kermadec in the Pacific basin. In these cases, however, subduction initiation would not

  2. Nuclear reactor alignment plate configuration

    SciTech Connect

    Altman, David A; Forsyth, David R; Smith, Richard E; Singleton, Norman R

    2014-01-28

    An alignment plate that is attached to a core barrel of a pressurized water reactor and fits within slots within a top plate of a lower core shroud and upper core plate to maintain lateral alignment of the reactor internals. The alignment plate is connected to the core barrel through two vertically-spaced dowel pins that extend from the outside surface of the core barrel through a reinforcement pad and into corresponding holes in the alignment plate. Additionally, threaded fasteners are inserted around the perimeter of the reinforcement pad and into the alignment plate to further secure the alignment plate to the core barrel. A fillet weld also is deposited around the perimeter of the reinforcement pad. To accomodate thermal growth between the alignment plate and the core barrel, a gap is left above, below and at both sides of one of the dowel pins in the alignment plate holes through with the dowel pins pass.

  3. Use of fractal zone plates for transmission X-ray microscopy.

    PubMed

    Ge, Xin; Wang, Zhili; Gao, Kun; Wang, Dajiang; Wu, Zhao; Chen, Jian; Pan, Zhiyun; Zhang, Kai; Hong, Youli; Zhu, Peiping; Wu, Ziyu

    2012-09-01

    In this contribution we discuss the possibility of designing a modified transmission X-ray microscope by using fractal zone plates (Fzps) as diffractive optical elements. In the modified transmission X-ray microscope optical layout, we first introduced a fractal zone plate as the microscope objective. Indeed, a fractal zone plate cannot only be used as an image-forming component but also as a condenser element to achieve an extended depth of field. Numerical analysis reveals that fractal zone plates and conventional Fresnel zone plates have similar imaging capabilities under different coherent illumination. Using a fractal zone plate as a condenser we also simulated axial irradiance. Results confirm that fractal zone plates can improve focusing capability with an extended depth of field. Although preliminary, these simulations clearly reveal that fractal zone plates, when available, will be of great help in microscope layouts, in particular for foreseen high-resolution applications in the "water window" as strongly required in biological research.

  4. The Plate Tectonics Project

    ERIC Educational Resources Information Center

    Hein, Annamae J.

    2011-01-01

    The Plate Tectonics Project is a multiday, inquiry-based unit that facilitates students as self-motivated learners. Reliable Web sites are offered to assist with lessons, and a summative rubric is used to facilitate the holistic nature of the project. After each topic (parts of the Earth, continental drift, etc.) is covered, the students will…

  5. The Plate Tectonics Project

    ERIC Educational Resources Information Center

    Hein, Annamae J.

    2011-01-01

    The Plate Tectonics Project is a multiday, inquiry-based unit that facilitates students as self-motivated learners. Reliable Web sites are offered to assist with lessons, and a summative rubric is used to facilitate the holistic nature of the project. After each topic (parts of the Earth, continental drift, etc.) is covered, the students will…

  6. INL HIP Plate Fabrication

    SciTech Connect

    B. H. Park; C. R. Clark; J. F. Jue

    2010-02-01

    This document outlines the process used to bond monolithic fuel plates by Hot Isostatic Pressing (HIP). This method was developed at Idaho National Laboratory (INL) for the Reduced Enrichment for Research and Test Reactors (RERTR) program. These foils have been used in a number of irradiation experiments in support of the United States Global Threat Reduction Initiative (GTRI) program.

  7. Unitary plate electrode

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor); Clough, Thomas J. (Inventor); Josefowicz, Jack Y. (Inventor); Sibert, John W. (Inventor)

    1985-01-01

    The unitary electrode (10) comprises a porous sheet (12) of fiberglass the strands (14) of which contain a coating (16) of conductive tin oxide. The lower portion of the sheet contains a layer (18) of resin and the upper layer (20) contains lead dioxide forming a positive active electrode on an electrolyte-impervious layer. The strands (14) form a continuous conduction path through both layers (16, 18). Tin oxide is prevented from reduction by coating the surface of the plate facing the negative electrode with a conductive, impervious layer resistant to reduction such as a thin film (130) of lead or graphite filled resin adhered to the plate with a layer (31) of conductive adhesive. The plate (10) can be formed by casting a molten resin from kettle (60) onto a sheet of glass wool (56) overlying a sheet of lead foil and then applying positive active paste from hopper (64) into the upper layer (68). The plate can also be formed by passing an assembly of a sheet ( 80) of resin, a sheet (86) of sintered glass and a sheet (90) of lead between the nip (92) of heated rollers (93, 95) and then filling lead oxide into the pores (116) of the upper layer (118).

  8. Optimizing ultrasonic imaging for adhesively bonded plates

    SciTech Connect

    Conboy, Mike; Hart, Scot; Harris-Weiel, David; Meyer, R. L.; Claytor, T. N.

    2004-01-01

    Bonded materials are used in many critical applications, making it important to determine the state of the adhesive during service or aging. It is also of importance, in many cases, to determine if the adhesive has uniformly and completely covered the area to be joined. Through dual transducer scanning, focused and unfocused transducers, and immersion scanning, the uniformity and adherence of a visco-elastic material can be evaluated. In this report, ultrasonic scanning parameters will be optimized experimentally with guidance from simulation tools including Wave 2000 pro and Imagine 3D. We explored optimizing the contrast ratio by varying the interrogation frequency and also by adjusting the distance between the transducer and bond line. An improvement in contrast should also increase the ability to detect differences in compositions and viscosity of the bonded layer. By maximizing the contrast the quality of the visco-elastic bond can be determined, and imperfections detected before adhesive failure.

  9. Image

    SciTech Connect

    Marsh, Amber; Harsch, Tim; Pitt, Julie; Firpo, Mike; Lekin, April; Pardes, Elizabeth

    2007-08-31

    The computer side of the IMAGE project consists of a collection of Perl scripts that perform a variety of tasks; scripts are available to insert, update and delete data from the underlying Oracle database, download data from NCBI's Genbank and other sources, and generate data files for download by interested parties. Web scripts make up the tracking interface, and various tools available on the project web-site (image.llnl.gov) that provide a search interface to the database.

  10. Engineering surface waves in flat phononic plates

    NASA Astrophysics Data System (ADS)

    Estrada, Héctor; Candelas, Pilar; Belmar, Francisco; Uris, Antonio; García de Abajo, F. Javier; Meseguer, Francisco

    2012-05-01

    Surface acoustic-wave phenomena span a wide range of length scales going from the devastation of earthquakes down to image reconstruction of buried nanostructures. In solid-fluid systems, the so-called Scholte-Stoneley waves (SSWs) dominate the scene at the interface with their evanescent fields decaying away into both media. Understanding and manipulating these waves in patterned surfaces would enable new applications of sound to be devised for imaging and acoustic signal processing, although this task has so far remained elusive. Here, we report SSW modes displaying directional gaps and band folding in fluid-loaded solid phononic plates. The plates are inhomogeneously patterned with in-plane periodic modulations of the elastic constants, but present flat surfaces free of corrugations. We experimentally demonstrate control of SSWs, which opens a promising route toward acoustic fluid sensing, microscopy, and signal processing.

  11. Antimicrobial efficiency of ethanol and 2-propanol alcohols used on contaminated storage phosphor plates and impact on durability of the plate

    PubMed Central

    Wenzel, A; Kornum, F; Knudsen, MR; Lau, E Frandsen

    2013-01-01

    Objectives: To assess (1) antimicrobial efficiency of wiping intraoral phosphor plates with alcohol tissues based on ethanol or 2-propanol alcohols after contamination with Candida albicans and Streptococcus oralis, (2) a concept for autodisinfection with ultraviolet light of the transport ramp in a scanner for phosphor plates and (3) the impact of wiping with alcohol tissues on durability of the plate. Methods: Suspensions of C. albicans and S. oralis were prepared in concentrations of 109 and 105 organisms per ml, and Digora (Digora® Optime Imaging Plate, size 2; Soredex, PalaDEx Group Brenntag Nordic A/S, Hellerup, Denmark) and Vista (VistaScan® Imaging Plate PLUS, size 2; Dürr Dental AG, Bietigheim-Bissingen, Germany) plates were contaminated. The plates were wiped with ethanol or 2-propanol disinfectant tissues and imprints obtained on agar. Number of microbial colonies after culturing was recorded. The scanner ramp was contaminated with C. albicans or S. oralis, respectively, the ultraviolet light (UV light) disinfection in the scanner was activated and the number of colonies after culturing was recorded. Plates from each system were sequentially wiped (5–60 times) with ethanol and 2-propanol, exposed and scanned. 48 images from each system were scored blind: 1 = no artefact, 2 = small artefacts and 3 = severe artefacts. Results: Ethanol eliminated C. albicans and S. oralis in high and low concentrations from both types of plates, whereas 2-propanol did not eliminate all micro-organisms at high concentrations. The UV light eliminated all micro-organisms from the ramp. Ethanol degraded the plates to a larger extent than did 2-propanol. Images from Vista plates showed severe artefacts after wiping with ethanol; those from Digora plates did not. Conclusions: Ethanol eliminated all micro-organisms but degraded phosphor plates, whereas 2-propanol did not eliminate all micro-organisms and still degraded plates from Vista but not from Digora. PMID

  12. Antimicrobial efficiency of ethanol and 2-propanol alcohols used on contaminated storage phosphor plates and impact on durability of the plate.

    PubMed

    Wenzel, A; Kornum, F; Knudsen, Mr; Lau, E Frandsen

    2013-01-01

    To assess (1) antimicrobial efficiency of wiping intraoral phosphor plates with alcohol tissues based on ethanol or 2-propanol alcohols after contamination with Candida albicans and Streptococcus oralis, (2) a concept for autodisinfection with ultraviolet light of the transport ramp in a scanner for phosphor plates and (3) the impact of wiping with alcohol tissues on durability of the plate. Suspensions of C. albicans and S. oralis were prepared in concentrations of 10(9) and 10(5) organisms per ml, and Digora (Digora(®) Optime Imaging Plate, size 2; Soredex, PalaDEx Group Brenntag Nordic A/S, Hellerup, Denmark) and Vista (VistaScan(®) Imaging Plate PLUS, size 2; Dürr Dental AG, Bietigheim-Bissingen, Germany) plates were contaminated. The plates were wiped with ethanol or 2-propanol disinfectant tissues and imprints obtained on agar. Number of microbial colonies after culturing was recorded. The scanner ramp was contaminated with C. albicans or S. oralis, respectively, the ultraviolet light (UV light) disinfection in the scanner was activated and the number of colonies after culturing was recorded. Plates from each system were sequentially wiped (5-60 times) with ethanol and 2-propanol, exposed and scanned. 48 images from each system were scored blind: 1 = no artefact, 2 = small artefacts and 3 = severe artefacts. Ethanol eliminated C. albicans and S. oralis in high and low concentrations from both types of plates, whereas 2-propanol did not eliminate all micro-organisms at high concentrations. The UV light eliminated all micro-organisms from the ramp. Ethanol degraded the plates to a larger extent than did 2-propanol. Images from Vista plates showed severe artefacts after wiping with ethanol; those from Digora plates did not. Ethanol eliminated all micro-organisms but degraded phosphor plates, whereas 2-propanol did not eliminate all micro-organisms and still degraded plates from Vista but not from Digora.

  13. Linear optical pulse compression based on temporal zone plates.

    PubMed

    Li, Bo; Li, Ming; Lou, Shuqin; Azaña, José

    2013-07-15

    We propose and demonstrate time-domain equivalents of spatial zone plates, namely temporal zone plates, as alternatives to conventional time lenses. Both temporal intensity zone plates, based on intensity-only temporal modulation, and temporal phase zone plates, based on phase-only temporal modulation, are introduced and studied. Temporal zone plates do not exhibit the limiting tradeoff between temporal aperture and frequency bandwidth (temporal resolution) of conventional linear time lenses. As a result, these zone plates can be ideally designed to offer a time-bandwidth product (TBP) as large as desired, practically limited by the achievable temporal modulation bandwidth (limiting the temporal resolution) and the amount of dispersion needed in the target processing systems (limiting the temporal aperture). We numerically and experimentally demonstrate linear optical pulse compression by using temporal zone plates based on linear electro-optic temporal modulation followed by fiber-optics dispersion. In the pulse-compression experiment based on temporal phase zone plates, we achieve a resolution of ~25.5 ps over a temporal aperture of ~5.77 ns, representing an experimental TBP larger than 226 using a phase-modulation amplitude of only ~0.8π rad. We also numerically study the potential of these devices to achieve temporal imaging of optical waveforms and present a comparative analysis on the performance of different temporal intensity and phase zone plates.

  14. Simplified silver-plating stain for flagella.

    PubMed Central

    West, M; Burdash, N M; Freimuth, F

    1977-01-01

    Rhodes' silver-plating technique for staining flagella was tested for its reliability and convenience as a routine procedure in the clinical laboratory. Modifications were made in the stain preparation and the procedure of staining and were tested with smears of known motile gram-negative nonfermentative bacilli. The stain has proved to be accurate and reliable and can be easily utilized with a minimum of training. Images PMID:72075

  15. What Are Growth Plate Injuries?

    MedlinePlus

    ... for growth plate injuries are:  Falling down  Competitive sports (like football)  Recreational activities. Other reasons for growth plate injuries are:  Child abuse  Injury from extreme cold (for example, frostbite)  Radiation (used to treat ...

  16. Renewable liquid reflecting zone plate

    DOEpatents

    Toor, Arthur; Ryutov, Dmitri D.

    2003-12-09

    A renewable liquid reflecting zone plate. Electrodes are operatively connected to a dielectric liquid in a circular or other arrangement to produce a reflecting zone plate. A system for renewing the liquid uses a penetrable substrate.

  17. Growth plate closure: Apex view on bone scan

    SciTech Connect

    Giles, P.H.; Trochei, M.; Yeates, K.

    1984-01-01

    Angular deformities of the extremities in children following premature closure of the growth plate are well known. The deformities depend on the position of an osseus bridge which forms between the epiphysis and metaphysis. Several surgical procedures including resection of the osseus bridge have been described, however, delineation of the site of fusion is difficult to define. The commonest site of growth plate arrest is the distal femoral or proximal tibial growth plate. A new technique using the bone scan has been developed which accurately defines the area and position of these osseus bridges. Two hours after injection of technetium 99m methylene diphosphonate apex views of the affected distal femoral growth plate were performed. The knee was flexed into its smallest angle. Using a pinhole collimator the gamma camera was angled to face the affected growth plate end on. The image was collected onto computer and analysed by: (I) regions of interest over segments of the growth plate to calculate the relative area of total growth plate affected: (II) generating histograms: (III) thresholding or performing isocontours to accentuate abnormal areas. The growth plate is normally uniformly increased when compared to the normal shaft of the bone. Fusion across the plate appears as an area of diminished uptake. The apex view gives a unique functional map of the growth plate such that abnormal areas are displayed, and the site, size and position of osseus fusion obtained. The technique has the potential for determining the metabolic activity of the growth plate before and after surgery. Serial studies will allow assessment of regneration of the plate and reformation of new osseus bridges.

  18. Microchannel plate streak camera

    DOEpatents

    Wang, Ching L.

    1989-01-01

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras. The improved streak camera is far more sensitive to photons (UV to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1000 KeV x-rays.

  19. North American plate dynamics

    NASA Technical Reports Server (NTRS)

    Richardson, Randall M.; Reding, Lynn M.

    1991-01-01

    Deformation within the North American plate in response to various tectonic processes is modeled using an elastic finite element analysis. The tectonic processes considered in the modeling include ridge forces associated with the normal thermal evolution of oceanic lithosphere, shear and normal stresses transmitted across transforms, normal stresses transmitted across convergent boundaries, stresses due to horizontal density contrasts within the continent, and shear tractions applied along the base of the plate. Model stresses are calculated with respect to a lithostatic reference stress state. Shear stresses transmitted across transform boundaries along the San Andreas and Caribbean are small, of the order of 5-10 MPa. Also, compressive stresses of the order of 5-10 MPa transmitted across the major transforms improve the fit to the data. Compressive stresses across convergent margins along the Aleutians and the Middle America trench are important.

  20. Bipolar battery plate

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor)

    1985-01-01

    A liquid-impermeable plate (10) having throughplate conductivity with essentially zero resistance comprises an insulator sheet (12) having a series of spaced perforations (14) each of which contains a metal element (16) sealingly received into the perforation (14). A low-cost plate can readily be manufactured by punching a thermoplastic sheet (40) such as polypropylene with a punching tool (52), filling the apertures with lead spheres (63) having a diameter smaller than the holes (50) but larger than the thickness of the sheet, sweeping excess spheres (62) off the sheet with a doctor blade (60) and then pressing a heated platen (74) onto the sheet to swage the spheres into a cylindrical shape and melt the surrounding resin to form a liquid-impermeable collar (4) sealing the metal into the sheet.

  1. Microchannel plate streak camera

    DOEpatents

    Wang, C.L.

    1984-09-28

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras. The improved streak camera is far more sensitive to photons (uv to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1000 keV x-rays.

  2. Microchannel plate streak camera

    DOEpatents

    Wang, C.L.

    1989-03-21

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras is disclosed. The improved streak camera is far more sensitive to photons (UV to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1,000 KeV x-rays. 3 figs.

  3. Mechanisms in Thermal Mechanical Forming of Plates.

    DTIC Science & Technology

    1987-05-01

    specific locations within the plate is discussed, and recommendations for further research are made. Keywords: Metal plates; Ship plates; Material forming; Thermomechanics; Edge effect ; Laser line heating.

  4. The Plate Overlap Technique.

    DTIC Science & Technology

    1978-07-31

    INTRODUCTION 1 II. NOTATION 2 III. THE GNOMONIC PROJECTION 4 IV . THE PLATE OVERLAP TECHNIQUE 6 A. MOTIVATION 6 B. FORNULATION 9 C. ON STATISTICAL RIGOR 14 D...and new hardware. Since this aim was clearly recognized long ago, wherever possible in earlier documents or software development flexibility was...reader should see 1, 2, and 3. The procedures one should use to update stellar positions are discussed in 4 with applica- tions to the SAOC in 5. Non

  5. Plated wire memory subsystem

    NASA Technical Reports Server (NTRS)

    Reynolds, L.; Tweed, H.

    1972-01-01

    The work performed entailed the design, development, construction and testing of a 4000 word by 18 bit random access, NDRO plated wire memory for use in conjunction with a spacecraft imput/output unit and central processing unit. The primary design parameters, in order of importance, were high reliability, low power, volume and weight. A single memory unit, referred to as a qualification model, was delivered.

  6. Elastic plate spallation

    NASA Technical Reports Server (NTRS)

    Oline, L.; Medaglia, J.

    1972-01-01

    The dynamic finite element method was used to investigate elastic stress waves in a plate. Strain displacement and stress strain relations are discussed along with the stiffness and mass matrix. The results of studying point load, and distributed load over small, intermediate, and large radii are reported. The derivation of finite element matrices, and the derivation of lumped and consistent matrices for one dimensional problems with Laplace transfer solutions are included. The computer program JMMSPALL is also included.

  7. Smov FOS Plate Scale

    NASA Astrophysics Data System (ADS)

    Kinney, Anne

    1994-01-01

    The goal is to measure the precise plate scale and orientation. This will be acheived by performing a raster step and dwell sequence in the 4.3 arcsec aperture. The edges of the aperture should be avoided to prevent vignetting effects. An aperture map is required at each step of the dwell sequence. This test has to be conducted for both the RED and BLUE detectors. We will also determine the offset between the two detectors.

  8. Electronic Equipment Cold Plates

    DTIC Science & Technology

    1976-04-01

    equations for such a flow regiae. For laainar flow and Moderate teaperature differwwe« between the well «nd coolant, a aodifled Sieder -Tate...con- figuration. The heat-transfer coefficients, therefore, were determined by using both the Sieder -Tate and McAdams equations and the coaputed...values used In the analytical predictions. As with th* previous cold Plates, the Sieder -Tate equation gave too low of values for the heat- transfer

  9. Martian plate tectonics

    NASA Astrophysics Data System (ADS)

    Sleep, N. H.

    1994-03-01

    The northern lowlands of Mars have been produced by plate tectonics. Preexisting old thick highland crust was subducted, while seafloor spreading produced thin lowland crust during late Noachian and Early Hesperian time. In the preferred reconstruction, a breakup margin extended north of Cimmeria Terra between Daedalia Planum and Isidis Planitia where the highland-lowland transition is relatively simple. South dipping subduction occured beneath Arabia Terra and east dipping subduction beneath Tharsis Montes and Tempe Terra. Lineations associated with Gordii Dorsum are attributed to ridge-parallel structures, while Phelegra Montes and Scandia Colles are interpreted as transfer-parallel structures or ridge-fault-fault triple junction tracks. Other than for these few features, there is little topographic roughness in the lowlands. Seafloor spreading, if it occurred, must have been relatively rapid. Quantitative estimates of spreading rate are obtained by considering the physics of seafloor spreading in the lower (approx. 0.4 g) gravity of Mars, the absence of vertical scarps from age differences across fracture zones, and the smooth axial topography. Crustal thickness at a given potential temperature in the mantle source region scales inversely with gravity. Thus, the velocity of the rough-smooth transition for axial topography also scales inversely with gravity. Plate reorganizations where young crust becomes difficult to subduct are another constraint on spreading age. Plate tectonics, if it occurred, dominated the thermal and stress history of the planet. A geochemical implication is that the lower gravity of Mars allows deeper hydrothermal circulation through cracks and hence more hydration of oceanic crust so that more water is easily subducted than on the Earth. Age and structural relationships from photogeology as well as median wavelength gravity anomalies across the now dead breakup and subduction margins are the data most likely to test and modify hypotheses

  10. Plate motion and deformation

    SciTech Connect

    Minster, B.; Prescott, W.; Royden, L.

    1991-02-01

    Our goal is to understand the motions of the plates, the deformation along their boundaries and within their interiors, and the processes that control these tectonic phenomena. In the broadest terms, we must strive to understand the relationships of regional and local deformation to flow in the upper mantle and the rheological, thermal and density structure of the lithosphere. The essential data sets which we require to reach our goal consist of maps of current strain rates at the earth's surface and the distribution of integrated deformation through time as recorded in the geologic record. Our success will depend on the effective synthesis of crustal kinematics with a variety of other geological and geophysical data, within a quantitative theoretical framework describing processes in the earth's interior. Only in this way can we relate the snapshot of current motions and earth structure provided by geodetic and geophysical data with long-term processes operating on the time scales relevant to most geological processes. The wide-spread use of space-based techniques, coupled with traditional geological and geophysical data, promises a revolution in our understanding of the kinematics and dynamics of plate motions over a broad range of spatial and temporal scales and in a variety of geologic settings. The space-based techniques that best address problems in plate motion and deformation are precise space-geodetic positioning -- on land and on the seafloor -- and satellite acquisition of detailed altimetric and remote sensing data in oceanic and continental areas. The overall science objectives for the NASA Solid Earth Science plan for the 1990's, are to Understand the motion and deformation of the lithosphere within and across plate boundaries'', and to understand the dynamics of the mantle, the structure and evolution of the lithosphere, and the landforms that result from local and regional deformation. 57 refs., 7 figs., 2 tabs.

  11. Armor Plate Surface Roughness Measurements

    DTIC Science & Technology

    2005-04-01

    Armor Plate Surface Roughness Measurements by Brian Stanton, William Coburn, and Thomas J. Pizzillo ARL-TR-3498 April 2005... Armor Plate Surface Roughness Measurements Brian Stanton, William Coburn and Thomas J. Pizzillo Sensors and Electron Devices Directorate...October 2004 5a. CONTRACT NUMBER 5b. GRANT NUMBER 4. TITLE AND SUBTITLE Armor Plate Surface Roughness Measurements 5c. PROGRAM ELEMENT NUMBER

  12. [Imaging].

    PubMed

    Chevrot, A; Drapé, J L; Godefroy, D; Dupont, A M; Pessis, E; Sarazin, L; Minoui, A

    1997-01-01

    The panoply of imaging techniques useful in podology is essentially limited to X-rays. Standard "standing" and "lying" X-rays furnish most of the required information. Arthrography is sometimes performed, in particular for trauma or tumour of the ankle. CT scan and MRI make a decisive contribution in difficult cases, notably in fractures and in small fractures without displacement. The two latter techniques are useful in tendon, ligament and muscular disorders, where echography is also informative. Rigorous analysis of radiographies and a good knowledge of foot disorders make these imaging techniques efficacious.

  13. Buckling of trapezoidal plates

    SciTech Connect

    Radloff, H.D.; Hyer, M.W.; Nemeth, M.P.

    1995-12-31

    This study focuses on the buckling response of flat composite plates with an isosceles planform, as shown below. The study consisted of both analytical and experimental phases. In the study the parallel edges x = 0 and L were clamped or simply supported. Clamped parallel edges were used in the experimental phase of the study. The nonparallel edges were simply supported. The parallel edges were assumed to remain straight and buckling was assumed to occur because these edges moved toward each other. A Rayleigh-Ritz approach was used, with the finite-element code ABAQUS being used to check specific cases. The buckling displacements were assumed to be in the form of harmonic functions. The prebuckling force resultant N{sub x} was assumed to be given by N{sub x}(x,y) = P/W(x), where P is the applied load and W(x) is the varying width of the plate. N{sub y}(x,y) and N{sub x,y}(x,y) were taken to be zero. Experiments were conducted on a number of laminates and a number of plate geometries, and the results were compared to predictions of the Rayleigh-Ritz scheme. In general correlation was good, though the analysis underpredicted the number of buckling half-waves.

  14. Images.

    ERIC Educational Resources Information Center

    Barr, Catherine, Ed.

    1997-01-01

    The theme of this month's issue is "Images"--from early paintings and statuary to computer-generated design. Resources on the theme include Web sites, CD-ROMs and software, videos, books, and others. A page of reproducible activities is also provided. Features include photojournalism, inspirational Web sites, art history, pop art, and myths. (AEF)

  15. Origin of Small Tectonic Plates

    NASA Astrophysics Data System (ADS)

    Mallard, C.; Coltice, N.; Seton, M.; Müller, D.; Tackley, P.

    2015-12-01

    The plate tectonic theory allowed to split the Earth surface into 6 (Le Pichon 1968) to 52 tectonic plates (Bird 2003). These plates are separated into two groups: the first of 7 large plates and the second of numerous smaller plates (Morra et al 2013). Previous studies using the reconstruction of the past 200 My, suggest that the size of large plates is driven by mantle flow. But the tools employed are descriptive (Morra et al 2013, Sornette and Pisarenko 2003), hence ignoring forces and physical principles within the lithosphere and the mantle. The processes at the origin of small plates remain unknown. We developed a new approach to explain the plate sizes. We demonstrate that the physics of convection drives it. We applied plate tectonics theory on 3D spherical convection models generating plate-like motions, which give access to a complete survey of data: velocities, viscosity and heat flow. Our data show that (1) the large plates depend on the dominating scale of the convective flow due to the initiation or the shutdown of subductions; (2) the smaller plates are generated thanks to large variability of regional stresses along subduction zone by slab pull and suction influenced by the geometry of trenches. Our results are consistent with the quick reorganizations of back-arc basins occuring synchronously with the modification of subduction zones geometry around the Pacific plate (Sdrolias et al 2004). Hence, we conclude that (1) the decreasing number of small plates in the plate reconstructions back in time is an artifact induced by their short lifetime, that is why they are artificially ignored; (2) the geometry of past trenches is simplified leading to an underestimation of the length of subduction zones.

  16. Electronic measurement of microchannel plate pulse height distributions

    SciTech Connect

    Gamboa, E. J.; Huntington, C. M.; Harding, E. C.; Drake, R. P.

    2010-10-15

    Microchannel plates are a central component of the x-ray framing cameras used as analog imagers in many plasma experiment diagnostic systems. The microchannel plate serves as an amplifying element, increasing the electronic signal from incident radiation by factors of 10{sup 3}-10{sup 5}, with a broad pulse-height distribution. Seeking to optimize the photon-to-electron conversion efficiency and noise distribution of x-ray cameras, we will characterize the pulse-height distribution of the electron output from a single microchannel plate. Replacing the framing camera's phosphor-coated fiber optic screen with a charge-collection plate and coupling to a low-noise multichannel analyzer, we quantified the distribution in the total charge generated per photon event. The electronically measured pulse height distribution is used to estimate the signal-to-noise ratio of radiographic images from framing cameras.

  17. Symmetries in laminated composite plates

    NASA Technical Reports Server (NTRS)

    Noor, A. K.

    1976-01-01

    The different types of symmetry exhibited by laminated anisotropic fibrous composite plates are identified and contrasted with the symmetries of isotropic and homogeneous orthotropic plates. The effects of variations in the fiber orientation and the stacking sequence of the layers on the symmetries exhibited by composite plates are discussed. Both the linear and geometrically nonlinear responses of the plates are considered. A simple procedure is presented for exploiting the symmetries in the finite element analysis. Examples are given of square, skew and polygonal plates where use of symmetry concepts can significantly reduce the scope and cost of analysis.

  18. Plate tectonics conserves angular momentum

    NASA Astrophysics Data System (ADS)

    Bowin, C.

    2009-03-01

    A new combined understanding of plate tectonics, Earth internal structure, and the role of impulse in deformation of the Earth's crust is presented. Plate accelerations and decelerations have been revealed by iterative filtering of the quaternion history for the Euler poles that define absolute plate motion history for the past 68 million years, and provide an unprecedented precision for plate angular rotation variations with time at 2-million year intervals. Stage poles represent the angular rotation of a plate's motion between adjacent Euler poles, and from which the maximum velocity vector for a plate can be determined. The consistent maximum velocity variations, in turn, yield consistent estimates of plate accelerations and decelerations. The fact that the Pacific plate was shown to accelerate and decelerate, implied that conservation of plate tectonic angular momentum must be globally conserved, and that is confirmed by the results shown here (total angular momentum ~1.4 E+27 kgm2s-1). Accordingly, if a plate decelerates, other plates must increase their angular momentums to compensate. In addition, the azimuth of the maximum velocity vectors yields clues as to why the "bend" in the Emperor-Hawaiian seamount trend occurred near 46 Myr. This report summarizes processing results for 12 of the 14 major tectonic plates of the Earth (except for the Juan de Fuca and Philippine plates). Plate accelerations support the contention that plate tectonics is a product of torques that most likely are sustained by the sinking of positive density anomalies due to phase changes in subducted gabbroic lithosphere at depth in the upper lower mantle (above 1200 km depth). The tectonic plates are pulled along by the sinking of these positive mass anomalies, rather than moving at near constant velocity on the crests of convection cells driven by rising heat. These results imply that spreading centers are primarily passive reactive features, and fracture zones (and wedge-shaped sites

  19. Plate fixation of prostheses after segmental resection for bone tumours.

    PubMed

    Coathup, M J; Cobb, J P; Walker, P S; Blunn, G W

    2000-11-01

    This study investigated the concept of using plates to attach endoprostheses to bone after segmental resection for bone tumours in an animal model. Titanium alloy plates integrated with the prosthesis and coated with hydroxyapatite were attached to bone by screws. This type of uncemented fixation relied on the induction of periosteal bone formation into and around the plates to secure the implant to bone. Two, three, and six-slotted plate designs were investigated. On retrieval, each plate was securely fixed by new bone. Bone apposition on the external surface of the plates occurred through a combination of periosteal bone production, invasion of bone through slots in the plate, and bone growth over the ends of the plates. Most plates became incorporated into a remodelled cortex. Higher bone turnover rates (microm day(-1)) were seen in bone in the slots of the plate compared with normal cortical bone turnover (p < 0.05). Significantly higher rates of turnover were measured beneath slotted parts of the plates compared with regions below the unslotted parts (p < 0.05). The cross-sectional area of bone surrounding the six-plate implant design was significantly higher than that of the three-plate (p < 0.05) and two-plate (p < 0.05) designs. In addition, significantly more bone formed adjacent to the six-plated implant design compared with that in the contralateral limb (p = 0.002). However, no significant difference was found when the total cortical area around the three-plated design was compared with that of the contralateral limb (p = 0.63). In contrast, significantly less bone was measured adjacent to the two-plate design than in the untreated limb (p = 0.001). Image analysis also demonstrated increased cortical porosity adjacent to the six-plate design compared with the three-plate (p = 0.004) and two-plate (p < 0.05) designs. Finite element analysis demonstrated that the six and three-plate designs increased the second moment of area compared with that in the

  20. Fuel cell end plate structure

    DOEpatents

    Guthrie, Robin J.; Katz, Murray; Schroll, Craig R.

    1991-04-23

    The end plates (16) of a fuel cell stack (12) are formed of a thin membrane. Pressure plates (20) exert compressive load through insulation layers (22, 26) to the membrane. Electrical contact between the end plates (16) and electrodes (50, 58) is maintained without deleterious making and breaking of electrical contacts during thermal transients. The thin end plate (16) under compressive load will not distort with a temperature difference across its thickness. Pressure plate (20) experiences a low thermal transient because it is insulated from the cell. The impact on the end plate of any slight deflection created in the pressure plate by temperature difference is minimized by the resilient pressure pad, in the form of insulation, therebetween.