The ImageJ ecosystem: an open platform for biomedical image analysis
Schindelin, Johannes; Rueden, Curtis T.; Hiner, Mark C.; Eliceiri, Kevin W.
2015-01-01
Technology in microscopy advances rapidly, enabling increasingly affordable, faster, and more precise quantitative biomedical imaging, which necessitates correspondingly more-advanced image processing and analysis techniques. A wide range of software is available – from commercial to academic, special-purpose to Swiss army knife, small to large–but a key characteristic of software that is suitable for scientific inquiry is its accessibility. Open-source software is ideal for scientific endeavors because it can be freely inspected, modified, and redistributed; in particular, the open-software platform ImageJ has had a huge impact on life sciences, and continues to do so. From its inception, ImageJ has grown significantly due largely to being freely available and its vibrant and helpful user community. Scientists as diverse as interested hobbyists, technical assistants, students, scientific staff, and advanced biology researchers use ImageJ on a daily basis, and exchange knowledge via its dedicated mailing list. Uses of ImageJ range from data visualization and teaching to advanced image processing and statistical analysis. The software's extensibility continues to attract biologists at all career stages as well as computer scientists who wish to effectively implement specific image-processing algorithms. In this review, we use the ImageJ project as a case study of how open-source software fosters its suites of software tools, making multitudes of image-analysis technology easily accessible to the scientific community. We specifically explore what makes ImageJ so popular, how it impacts life science, how it inspires other projects, and how it is self-influenced by coevolving projects within the ImageJ ecosystem. PMID:26153368
The ImageJ ecosystem: An open platform for biomedical image analysis.
Schindelin, Johannes; Rueden, Curtis T; Hiner, Mark C; Eliceiri, Kevin W
2015-01-01
Technology in microscopy advances rapidly, enabling increasingly affordable, faster, and more precise quantitative biomedical imaging, which necessitates correspondingly more-advanced image processing and analysis techniques. A wide range of software is available-from commercial to academic, special-purpose to Swiss army knife, small to large-but a key characteristic of software that is suitable for scientific inquiry is its accessibility. Open-source software is ideal for scientific endeavors because it can be freely inspected, modified, and redistributed; in particular, the open-software platform ImageJ has had a huge impact on the life sciences, and continues to do so. From its inception, ImageJ has grown significantly due largely to being freely available and its vibrant and helpful user community. Scientists as diverse as interested hobbyists, technical assistants, students, scientific staff, and advanced biology researchers use ImageJ on a daily basis, and exchange knowledge via its dedicated mailing list. Uses of ImageJ range from data visualization and teaching to advanced image processing and statistical analysis. The software's extensibility continues to attract biologists at all career stages as well as computer scientists who wish to effectively implement specific image-processing algorithms. In this review, we use the ImageJ project as a case study of how open-source software fosters its suites of software tools, making multitudes of image-analysis technology easily accessible to the scientific community. We specifically explore what makes ImageJ so popular, how it impacts the life sciences, how it inspires other projects, and how it is self-influenced by coevolving projects within the ImageJ ecosystem. © 2015 Wiley Periodicals, Inc.
IJ-OpenCV: Combining ImageJ and OpenCV for processing images in biomedicine.
Domínguez, César; Heras, Jónathan; Pascual, Vico
2017-05-01
The effective processing of biomedical images usually requires the interoperability of diverse software tools that have different aims but are complementary. The goal of this work is to develop a bridge to connect two of those tools: ImageJ, a program for image analysis in life sciences, and OpenCV, a computer vision and machine learning library. Based on a thorough analysis of ImageJ and OpenCV, we detected the features of these systems that could be enhanced, and developed a library to combine both tools, taking advantage of the strengths of each system. The library was implemented on top of the SciJava converter framework. We also provide a methodology to use this library. We have developed the publicly available library IJ-OpenCV that can be employed to create applications combining features from both ImageJ and OpenCV. From the perspective of ImageJ developers, they can use IJ-OpenCV to easily create plugins that use any functionality provided by the OpenCV library and explore different alternatives. From the perspective of OpenCV developers, this library provides a link to the ImageJ graphical user interface and all its features to handle regions of interest. The IJ-OpenCV library bridges the gap between ImageJ and OpenCV, allowing the connection and the cooperation of these two systems. Copyright © 2017 Elsevier Ltd. All rights reserved.
SlideJ: An ImageJ plugin for automated processing of whole slide images.
Della Mea, Vincenzo; Baroni, Giulia L; Pilutti, David; Di Loreto, Carla
2017-01-01
The digital slide, or Whole Slide Image, is a digital image, acquired with specific scanners, that represents a complete tissue sample or cytological specimen at microscopic level. While Whole Slide image analysis is recognized among the most interesting opportunities, the typical size of such images-up to Gpixels- can be very demanding in terms of memory requirements. Thus, while algorithms and tools for processing and analysis of single microscopic field images are available, Whole Slide images size makes the direct use of such tools prohibitive or impossible. In this work a plugin for ImageJ, named SlideJ, is proposed with the objective to seamlessly extend the application of image analysis algorithms implemented in ImageJ for single microscopic field images to a whole digital slide analysis. The plugin has been complemented by examples of macro in the ImageJ scripting language to demonstrate its use in concrete situations.
SlideJ: An ImageJ plugin for automated processing of whole slide images
Baroni, Giulia L.; Pilutti, David; Di Loreto, Carla
2017-01-01
The digital slide, or Whole Slide Image, is a digital image, acquired with specific scanners, that represents a complete tissue sample or cytological specimen at microscopic level. While Whole Slide image analysis is recognized among the most interesting opportunities, the typical size of such images—up to Gpixels- can be very demanding in terms of memory requirements. Thus, while algorithms and tools for processing and analysis of single microscopic field images are available, Whole Slide images size makes the direct use of such tools prohibitive or impossible. In this work a plugin for ImageJ, named SlideJ, is proposed with the objective to seamlessly extend the application of image analysis algorithms implemented in ImageJ for single microscopic field images to a whole digital slide analysis. The plugin has been complemented by examples of macro in the ImageJ scripting language to demonstrate its use in concrete situations. PMID:28683129
ImageJ: Image processing and analysis in Java
NASA Astrophysics Data System (ADS)
Rasband, W. S.
2012-06-01
ImageJ is a public domain Java image processing program inspired by NIH Image. It can display, edit, analyze, process, save and print 8-bit, 16-bit and 32-bit images. It can read many image formats including TIFF, GIF, JPEG, BMP, DICOM, FITS and "raw". It supports "stacks", a series of images that share a single window. It is multithreaded, so time-consuming operations such as image file reading can be performed in parallel with other operations.
AstroImageJ: Image Processing and Photometric Extraction for Ultra-precise Astronomical Light Curves
NASA Astrophysics Data System (ADS)
Collins, Karen A.; Kielkopf, John F.; Stassun, Keivan G.; Hessman, Frederic V.
2017-02-01
ImageJ is a graphical user interface (GUI) driven, public domain, Java-based, software package for general image processing traditionally used mainly in life sciences fields. The image processing capabilities of ImageJ are useful and extendable to other scientific fields. Here we present AstroImageJ (AIJ), which provides an astronomy specific image display environment and tools for astronomy specific image calibration and data reduction. Although AIJ maintains the general purpose image processing capabilities of ImageJ, AIJ is streamlined for time-series differential photometry, light curve detrending and fitting, and light curve plotting, especially for applications requiring ultra-precise light curves (e.g., exoplanet transits). AIJ reads and writes standard Flexible Image Transport System (FITS) files, as well as other common image formats, provides FITS header viewing and editing, and is World Coordinate System aware, including an automated interface to the astrometry.net web portal for plate solving images. AIJ provides research grade image calibration and analysis tools with a GUI driven approach, and easily installed cross-platform compatibility. It enables new users, even at the level of undergraduate student, high school student, or amateur astronomer, to quickly start processing, modeling, and plotting astronomical image data with one tightly integrated software package.
Contact Angle Measurements Using a Simplified Experimental Setup
ERIC Educational Resources Information Center
Lamour, Guillaume; Hamraoui, Ahmed; Buvailo, Andrii; Xing, Yangjun; Keuleyan, Sean; Prakash, Vivek; Eftekhari-Bafrooei, Ali; Borguet, Eric
2010-01-01
A basic and affordable experimental apparatus is described that measures the static contact angle of a liquid drop in contact with a solid. The image of the drop is made with a simple digital camera by taking a picture that is magnified by an optical lens. The profile of the drop is then processed with ImageJ free software. The ImageJ contact…
Slide Set: Reproducible image analysis and batch processing with ImageJ.
Nanes, Benjamin A
2015-11-01
Most imaging studies in the biological sciences rely on analyses that are relatively simple. However, manual repetition of analysis tasks across multiple regions in many images can complicate even the simplest analysis, making record keeping difficult, increasing the potential for error, and limiting reproducibility. While fully automated solutions are necessary for very large data sets, they are sometimes impractical for the small- and medium-sized data sets common in biology. Here we present the Slide Set plugin for ImageJ, which provides a framework for reproducible image analysis and batch processing. Slide Set organizes data into tables, associating image files with regions of interest and other relevant information. Analysis commands are automatically repeated over each image in the data set, and multiple commands can be chained together for more complex analysis tasks. All analysis parameters are saved, ensuring transparency and reproducibility. Slide Set includes a variety of built-in analysis commands and can be easily extended to automate other ImageJ plugins, reducing the manual repetition of image analysis without the set-up effort or programming expertise required for a fully automated solution.
Fiji: an open-source platform for biological-image analysis.
Schindelin, Johannes; Arganda-Carreras, Ignacio; Frise, Erwin; Kaynig, Verena; Longair, Mark; Pietzsch, Tobias; Preibisch, Stephan; Rueden, Curtis; Saalfeld, Stephan; Schmid, Benjamin; Tinevez, Jean-Yves; White, Daniel James; Hartenstein, Volker; Eliceiri, Kevin; Tomancak, Pavel; Cardona, Albert
2012-06-28
Fiji is a distribution of the popular open-source software ImageJ focused on biological-image analysis. Fiji uses modern software engineering practices to combine powerful software libraries with a broad range of scripting languages to enable rapid prototyping of image-processing algorithms. Fiji facilitates the transformation of new algorithms into ImageJ plugins that can be shared with end users through an integrated update system. We propose Fiji as a platform for productive collaboration between computer science and biology research communities.
ImageJ-MATLAB: a bidirectional framework for scientific image analysis interoperability.
Hiner, Mark C; Rueden, Curtis T; Eliceiri, Kevin W
2017-02-15
ImageJ-MATLAB is a lightweight Java library facilitating bi-directional interoperability between MATLAB and ImageJ. By defining a standard for translation between matrix and image data structures, researchers are empowered to select the best tool for their image-analysis tasks. Freely available extension to ImageJ2 ( http://imagej.net/Downloads ). Installation and use instructions available at http://imagej.net/MATLAB_Scripting. Tested with ImageJ 2.0.0-rc-54 , Java 1.8.0_66 and MATLAB R2015b. eliceiri@wisc.edu. Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com
SoilJ - An ImageJ plugin for semi-automatized image-processing of 3-D X-ray images of soil columns
NASA Astrophysics Data System (ADS)
Koestel, John
2016-04-01
3-D X-ray imaging is a formidable tool for quantifying soil structural properties which are known to be extremely diverse. This diversity necessitates the collection of large sample sizes for adequately representing the spatial variability of soil structure at a specific sampling site. One important bottleneck of using X-ray imaging is however the large amount of time required by a trained specialist to process the image data which makes it difficult to process larger amounts of samples. The software SoilJ aims at removing this bottleneck by automatizing most of the required image processing steps needed to analyze image data of cylindrical soil columns. SoilJ is a plugin of the free Java-based image-processing software ImageJ. The plugin is designed to automatically process all images located with a designated folder. In a first step, SoilJ recognizes the outlines of the soil column upon which the column is rotated to an upright position and placed in the center of the canvas. Excess canvas is removed from the images. Then, SoilJ samples the grey values of the column material as well as the surrounding air in Z-direction. Assuming that the column material (mostly PVC of aluminium) exhibits a spatially constant density, these grey values serve as a proxy for the image illumination at a specific Z-coordinate. Together with the grey values of the air they are used to correct image illumination fluctuations which often occur along the axis of rotation during image acquisition. SoilJ includes also an algorithm for beam-hardening artefact removal and extended image segmentation options. Finally, SoilJ integrates the morphology analyses plugins of BoneJ (Doube et al., 2006, BoneJ Free and extensible bone image analysis in ImageJ. Bone 47: 1076-1079) and provides an ASCII file summarizing these measures for each investigated soil column, respectively. In the future it is planned to integrate SoilJ into FIJI, the maintained and updated edition of ImageJ with selected plugins.
TANGO: a generic tool for high-throughput 3D image analysis for studying nuclear organization.
Ollion, Jean; Cochennec, Julien; Loll, François; Escudé, Christophe; Boudier, Thomas
2013-07-15
The cell nucleus is a highly organized cellular organelle that contains the genetic material. The study of nuclear architecture has become an important field of cellular biology. Extracting quantitative data from 3D fluorescence imaging helps understand the functions of different nuclear compartments. However, such approaches are limited by the requirement for processing and analyzing large sets of images. Here, we describe Tools for Analysis of Nuclear Genome Organization (TANGO), an image analysis tool dedicated to the study of nuclear architecture. TANGO is a coherent framework allowing biologists to perform the complete analysis process of 3D fluorescence images by combining two environments: ImageJ (http://imagej.nih.gov/ij/) for image processing and quantitative analysis and R (http://cran.r-project.org) for statistical processing of measurement results. It includes an intuitive user interface providing the means to precisely build a segmentation procedure and set-up analyses, without possessing programming skills. TANGO is a versatile tool able to process large sets of images, allowing quantitative study of nuclear organization. TANGO is composed of two programs: (i) an ImageJ plug-in and (ii) a package (rtango) for R. They are both free and open source, available (http://biophysique.mnhn.fr/tango) for Linux, Microsoft Windows and Macintosh OSX. Distribution is under the GPL v.2 licence. thomas.boudier@snv.jussieu.fr Supplementary data are available at Bioinformatics online.
Counting pollen grains using readily available, free image processing and analysis software.
Costa, Clayton M; Yang, Suann
2009-10-01
Although many methods exist for quantifying the number of pollen grains in a sample, there are few standard methods that are user-friendly, inexpensive and reliable. The present contribution describes a new method of counting pollen using readily available, free image processing and analysis software. Pollen was collected from anthers of two species, Carduus acanthoides and C. nutans (Asteraceae), then illuminated on slides and digitally photographed through a stereomicroscope. Using ImageJ (NIH), these digital images were processed to remove noise and sharpen individual pollen grains, then analysed to obtain a reliable total count of the number of grains present in the image. A macro was developed to analyse multiple images together. To assess the accuracy and consistency of pollen counting by ImageJ analysis, counts were compared with those made by the human eye. Image analysis produced pollen counts in 60 s or less per image, considerably faster than counting with the human eye (5-68 min). In addition, counts produced with the ImageJ procedure were similar to those obtained by eye. Because count parameters are adjustable, this image analysis protocol may be used for many other plant species. Thus, the method provides a quick, inexpensive and reliable solution to counting pollen from digital images, not only reducing the chance of error but also substantially lowering labour requirements.
Haque, Ayesha; Khan, Muhammad Yunus
2017-09-01
To assess the total volume change in a retinoic acid-induced, hypoplastic model of a chick thymus using Image-J. This experimental study was carried out at the anatomy department of College of Physicians and Surgeons, Islamabad, Pakistan, from February 2009 to February 2010, and comprised fertilised chicken eggs. The eggs were divided into experimental group A and control group C. Group A was injected with 0.3µg of retinoic acid via yolk sac to induce a defective model of a thymus with hypoplasia. The chicks were sacrificed on embryonic day 15 and at hatching. The thymus of each animal was processed, serially sectioned and stained. The total area of each section of thymus was calculated using Image-J. This total area was summed and multiplied with the thickness of each section to obtain volume. Of the 120 eggs, there were 60(50%) in each group. Image analysis revealed a highly significant decrease in the volume of the chick thymus in the experimental group A than its matched control at the time of hatching (p=0.001). Moreover, volumetric depletion progressed with time, being substantially pronounced at hatching compared to the embryonic stage. The volume changes were significant and were effectively quantified using Image-J.
A high-level 3D visualization API for Java and ImageJ.
Schmid, Benjamin; Schindelin, Johannes; Cardona, Albert; Longair, Mark; Heisenberg, Martin
2010-05-21
Current imaging methods such as Magnetic Resonance Imaging (MRI), Confocal microscopy, Electron Microscopy (EM) or Selective Plane Illumination Microscopy (SPIM) yield three-dimensional (3D) data sets in need of appropriate computational methods for their analysis. The reconstruction, segmentation and registration are best approached from the 3D representation of the data set. Here we present a platform-independent framework based on Java and Java 3D for accelerated rendering of biological images. Our framework is seamlessly integrated into ImageJ, a free image processing package with a vast collection of community-developed biological image analysis tools. Our framework enriches the ImageJ software libraries with methods that greatly reduce the complexity of developing image analysis tools in an interactive 3D visualization environment. In particular, we provide high-level access to volume rendering, volume editing, surface extraction, and image annotation. The ability to rely on a library that removes the low-level details enables concentrating software development efforts on the algorithm implementation parts. Our framework enables biomedical image software development to be built with 3D visualization capabilities with very little effort. We offer the source code and convenient binary packages along with extensive documentation at http://3dviewer.neurofly.de.
Liver Volumetry Plug and Play: Do It Yourself with ImageJ
Dello, Simon A. W. G.; van Dam, Ronald M.; Slangen, Jules J. G.; van de Poll, Marcel C. G.; Bemelmans, Marc H. A.; Greve, Jan Willem W. M.; Beets-Tan, Regina G. H.; Wigmore, Stephen J.
2007-01-01
Background A small remnant liver volume is an important risk factor for posthepatectomy liver failure and can be predicted accurately by computed tomography (CT) volumetry using radiologic image analysis software. Unfortunately, this software is expensive and usually requires support by a radiologist. ImageJ is a freely downloadable image analysis software package developed by the National Institute of Health (NIH) and brings liver volumetry to the surgeon’s desktop. We aimed to assess the accuracy of ImageJ for hepatic CT volumetry. Methods ImageJ was downloaded from http://www.rsb.info.nih.gov/ij/. Preoperative CT scans of 15 patients who underwent liver resection for colorectal cancer liver metastases were retrospectively analyzed. Scans were opened in ImageJ; and the liver, all metastases, and the intended parenchymal transection line were manually outlined on each slice. The area of each selected region, metastasis, resection specimen, and remnant liver was multiplied by the slice thickness to calculate volume. Volumes of virtual liver resection specimens measured with ImageJ were compared with specimen weights and calculated volumes obtained during pathology examination after resection. Results There was an excellent correlation between the volumes calculated with ImageJ and the actual measured weights of the resection specimens (r² = 0.98, p < 0.0001). The weight/volume ratio amounted to 0.88 ± 0.04 (standard error) and was in agreement with our earlier findings using CT-linked radiologic software. Conclusion ImageJ can be used for accurate hepatic CT volumetry on a personal computer. This application brings CT volumetry to the surgeon’s desktop at no expense and is particularly useful in cases of tertiary referred patients, who already have a proper CT scan on CD-ROM from the referring institution. Most likely the discrepancy between volume and weight results from exsanguination of the liver after resection. PMID:17726630
Ovesný, Martin; Křížek, Pavel; Borkovec, Josef; Švindrych, Zdeněk; Hagen, Guy M.
2014-01-01
Summary: ThunderSTORM is an open-source, interactive and modular plug-in for ImageJ designed for automated processing, analysis and visualization of data acquired by single-molecule localization microscopy methods such as photo-activated localization microscopy and stochastic optical reconstruction microscopy. ThunderSTORM offers an extensive collection of processing and post-processing methods so that users can easily adapt the process of analysis to their data. ThunderSTORM also offers a set of tools for creation of simulated data and quantitative performance evaluation of localization algorithms using Monte Carlo simulations. Availability and implementation: ThunderSTORM and the online documentation are both freely accessible at https://code.google.com/p/thunder-storm/ Contact: guy.hagen@lf1.cuni.cz Supplementary information: Supplementary data are available at Bioinformatics online. PMID:24771516
ImgLib2--generic image processing in Java.
Pietzsch, Tobias; Preibisch, Stephan; Tomancák, Pavel; Saalfeld, Stephan
2012-11-15
ImgLib2 is an open-source Java library for n-dimensional data representation and manipulation with focus on image processing. It aims at minimizing code duplication by cleanly separating pixel-algebra, data access and data representation in memory. Algorithms can be implemented for classes of pixel types and generic access patterns by which they become independent of the specific dimensionality, pixel type and data representation. ImgLib2 illustrates that an elegant high-level programming interface can be achieved without sacrificing performance. It provides efficient implementations of common data types, storage layouts and algorithms. It is the data model underlying ImageJ2, the KNIME Image Processing toolbox and an increasing number of Fiji-Plugins. ImgLib2 is licensed under BSD. Documentation and source code are available at http://imglib2.net and in a public repository at https://github.com/imagej/imglib. Supplementary data are available at Bioinformatics Online. saalfeld@mpi-cbg.de
NIH Image to ImageJ: 25 years of Image Analysis
Schneider, Caroline A.; Rasband, Wayne S.; Eliceiri, Kevin W.
2017-01-01
For the past twenty five years the NIH family of imaging software, NIH Image and ImageJ have been pioneers as open tools for scientific image analysis. We discuss the origins, challenges and solutions of these two programs, and how their history can serve to advise and inform other software projects. PMID:22930834
Quantitative Analysis of the Area of the Apical Ectodermal Ridge in Chick Appendages Using Image-J.
Syed, Hamd Binte Shahab; Khan, Muhammad Yunus
2018-06-01
To determine the effect of sodium phenytoin on the apical ectodermal ridges (AER) of chick wing buds by using the software program Image-J. An experimental study. Department of Anatomy, Regional Center, College of Physicians and Surgeons Pakistan (CPSP), Islamabad, from January 2014 to January 2015. Sixty fertilised chicken eggs of 'Egyptian fayoumi' breed were selected and separated into experimental (B) and control (A) groups, each having 30 eggs. A single dose of 3.5 mg sodium phenytoin was injected into each egg of the experimental group. The controls were injected with the same volume of normal saline. Developing embryos were extracted 96 hours (day 4) after incubation and histological sections were cut at 5 μm thickness. These sections were stained with Feulgen Nuclear and Light Green. The area of apical ectodermal ridges of chick wing buds was calculated by employing Image-J and subjected to statistical analysis. The difference between the mean values of the area of apical ectodermal ridges of experimental and control groups, as calculated by Image-J, was found to be statistically insignificant. Change in the area of the apical ectodermal ridges in experimental chicks, following phenytoin exposure, was insignificant as proven on the basis of quantification by Image-J.
ERIC Educational Resources Information Center
Lewicki, Martin; Hughes, Stephen
2012-01-01
This article describes a method for making a spectroscope from scrap materials, i.e. a fragment of compact disc, a cardboard box, a tube and a digital camera to record the spectrum. An image processing program such as ImageJ can be used to calculate the wavelength of emission and absorption lines from the digital photograph. Multiple images of a…
Gallo-Oller, Gabriel; Ordoñez, Raquel; Dotor, Javier
2018-06-01
Since its first description, Western blot has been widely used in molecular labs. It constitutes a multistep method that allows the detection and/or quantification of proteins from simple to complex protein mixtures. Western blot quantification method constitutes a critical step in order to obtain accurate and reproducible results. Due to the technical knowledge required for densitometry analysis together with the resources availability, standard office scanners are often used for the imaging acquisition of developed Western blot films. Furthermore, the use of semi-quantitative software as ImageJ (Java-based image-processing and analysis software) is clearly increasing in different scientific fields. In this work, we describe the use of office scanner coupled with the ImageJ software together with a new image background subtraction method for accurate Western blot quantification. The proposed method represents an affordable, accurate and reproducible approximation that could be used in the presence of limited resources availability. Copyright © 2018 Elsevier B.V. All rights reserved.
A comparative study of 2 computer-assisted methods of quantifying brightfield microscopy images.
Tse, George H; Marson, Lorna P
2013-10-01
Immunohistochemistry continues to be a powerful tool for the detection of antigens. There are several commercially available software packages that allow image analysis; however, these can be complex, require relatively high level of computer skills, and can be expensive. We compared 2 commonly available software packages, Adobe Photoshop CS6 and ImageJ, in their ability to quantify percentage positive area after picrosirius red (PSR) staining and 3,3'-diaminobenzidine (DAB) staining. On analysis of DAB-stained B cells in the mouse spleen, with a biotinylated primary rat anti-mouse-B220 antibody, there was no significant difference on converting images from brightfield microscopy to binary images to measure black and white pixels using ImageJ compared with measuring a range of brown pixels with Photoshop (Student t test, P=0.243, correlation r=0.985). When analyzing mouse kidney allografts stained with PSR, Photoshop achieved a greater interquartile range while maintaining a lower 10th percentile value compared with analysis with ImageJ. A lower 10% percentile reflects that Photoshop analysis is better at analyzing tissues with low levels of positive pixels; particularly relevant for control tissues or negative controls, whereas after ImageJ analysis the same images would result in spuriously high levels of positivity. Furthermore comparing the 2 methods by Bland-Altman plot revealed that these 2 methodologies did not agree when measuring images with a higher percentage of positive staining and correlation was poor (r=0.804). We conclude that for computer-assisted analysis of images of DAB-stained tissue there is no difference between using Photoshop or ImageJ. However, for analysis of color images where differentiation into a binary pattern is not easy, such as with PSR, Photoshop is superior at identifying higher levels of positivity while maintaining differentiation of low levels of positive staining.
A Multimedia Database Management System Supporting Contents Search in Media Data
1989-03-01
predicates: car (x), manufacturer (x, Horch ), year-built (x, 1922) to designate that the car was manufactured by Horch in the year 1922. The use of the name...manufacturer (imagel, x, " Horch "). year-built (imagel, x, 1922). query(I) :- car (I, Z), manufacturer (I, Z, " Horch "). ?- query(Image). yes. Image = image... Horch ) : imageJ 1, imageJ2, etc. In certain cases a predicate may generate entries in more than one list. For example, if the predicate of action
Gustafsson, Nils; Culley, Siân; Ashdown, George; Owen, Dylan M.; Pereira, Pedro Matos; Henriques, Ricardo
2016-01-01
Despite significant progress, high-speed live-cell super-resolution studies remain limited to specialized optical setups, generally requiring intense phototoxic illumination. Here, we describe a new analytical approach, super-resolution radial fluctuations (SRRF), provided as a fast graphics processing unit-enabled ImageJ plugin. In the most challenging data sets for super-resolution, such as those obtained in low-illumination live-cell imaging with GFP, we show that SRRF is generally capable of achieving resolutions better than 150 nm. Meanwhile, for data sets similar to those obtained in PALM or STORM imaging, SRRF achieves resolutions approaching those of standard single-molecule localization analysis. The broad applicability of SRRF and its performance at low signal-to-noise ratios allows super-resolution using modern widefield, confocal or TIRF microscopes with illumination orders of magnitude lower than methods such as PALM, STORM or STED. We demonstrate this by super-resolution live-cell imaging over timescales ranging from minutes to hours. PMID:27514992
NASA Astrophysics Data System (ADS)
Tomczak, Kamil; Jakubowski, Jacek; Fiołek, Przemysław
2017-06-01
Crack width measurement is an important element of research on the progress of self-healing cement composites. Due to the nature of this research, the method of measuring the width of cracks and their changes over time must meet specific requirements. The article presents a novel method of measuring crack width based on images from a scanner with an optical resolution of 6400 dpi, subject to initial image processing in the ImageJ development environment and further processing and analysis of results. After registering a series of images of the cracks at different times using SIFT conversion (Scale-Invariant Feature Transform), a dense network of line segments is created in all images, intersecting the cracks perpendicular to the local axes. Along these line segments, brightness profiles are extracted, which are the basis for determination of crack width. The distribution and rotation of the line of intersection in a regular layout, automation of transformations, management of images and profiles of brightness, and data analysis to determine the width of cracks and their changes over time are made automatically by own code in the ImageJ and VBA environment. The article describes the method, tests on its properties, sources of measurement uncertainty. It also presents an example of application of the method in research on autogenous self-healing of concrete, specifically the ability to reduce a sample crack width and its full closure within 28 days of the self-healing process.
Validation of a Novel Technique and Evaluation of the Surface Free Energy of Food
Senturk Parreidt, Tugce; Schmid, Markus; Hauser, Carolin
2017-01-01
Characterizing the physical properties of a surface is largely dependent on determining the contact angle exhibited by a liquid. Contact angles on the surfaces of rough and irregularly-shaped food samples are difficult to measure using a contact angle meter (goniometer). As a consequence, values for the surface energy and its components can be mismeasured. The aim of this work was to use a novel contact angle measurement method, namely the snake-based ImageJ program, to accurately measure the contact angles of rough and irregular shapes, such as food samples, and so enable more accurate calculation of the surface energy of food materials. In order to validate the novel technique, the contact angles of three different test liquids on four different smooth polymer films were measured using both the ImageJ software with the DropSnake plugin and the widely used contact angle meter. The distributions of the values obtained by the two methods were different. Therefore, the contact angles, surface energies, and polar and dispersive components of plastic films obtained using the ImageJ program and the Drop Shape Analyzer (DSA) were interpreted with the help of simple linear regression analysis. As case studies, the superficial characteristics of strawberry and endive salad epicarp were measured with the ImageJ program and the results were interpreted with the Drop Shape Analyzer equivalent according to our regression models. The data indicated that the ImageJ program can be successfully used for contact angle determination of rough and strongly hydrophobic surfaces, such as strawberry epicarp. However, for the special geometry of droplets on slightly hydrophobic surfaces, such as salad leaves, the program code interpolation part can be altered. PMID:28425932
A Novel ImageJ Macro for Automated Cell Death Quantitation in the Retina
Maidana, Daniel E.; Tsoka, Pavlina; Tian, Bo; Dib, Bernard; Matsumoto, Hidetaka; Kataoka, Keiko; Lin, Haijiang; Miller, Joan W.; Vavvas, Demetrios G.
2015-01-01
Purpose TUNEL assay is widely used to evaluate cell death. Quantification of TUNEL-positive (TUNEL+) cells in tissue sections is usually performed manually, ideally by two masked observers. This process is time consuming, prone to measurement errors, and not entirely reproducible. In this paper, we describe an automated quantification approach to address these difficulties. Methods We developed an ImageJ macro to quantitate cell death by TUNEL assay in retinal cross-section images. The script was coded using IJ1 programming language. To validate this tool, we selected a dataset of TUNEL assay digital images, calculated layer area and cell count manually (done by two observers), and compared measurements between observers and macro results. Results The automated macro segmented outer nuclear layer (ONL) and inner nuclear layer (INL) successfully. Automated TUNEL+ cell counts were in-between counts of inexperienced and experienced observers. The intraobserver coefficient of variation (COV) ranged from 13.09% to 25.20%. The COV between both observers was 51.11 ± 25.83% for the ONL and 56.07 ± 24.03% for the INL. Comparing observers' results with macro results, COV was 23.37 ± 15.97% for the ONL and 23.44 ± 18.56% for the INL. Conclusions We developed and validated an ImageJ macro that can be used as an accurate and precise quantitative tool for retina researchers to achieve repeatable, unbiased, fast, and accurate cell death quantitation. We believe that this standardized measurement tool could be advantageous to compare results across different research groups, as it is freely available as open source. PMID:26469755
Almeida, Jonas S.; Iriabho, Egiebade E.; Gorrepati, Vijaya L.; Wilkinson, Sean R.; Grüneberg, Alexander; Robbins, David E.; Hackney, James R.
2012-01-01
Background: Image bioinformatics infrastructure typically relies on a combination of server-side high-performance computing and client desktop applications tailored for graphic rendering. On the server side, matrix manipulation environments are often used as the back-end where deployment of specialized analytical workflows takes place. However, neither the server-side nor the client-side desktop solution, by themselves or combined, is conducive to the emergence of open, collaborative, computational ecosystems for image analysis that are both self-sustained and user driven. Materials and Methods: ImageJS was developed as a browser-based webApp, untethered from a server-side backend, by making use of recent advances in the modern web browser such as a very efficient compiler, high-end graphical rendering capabilities, and I/O tailored for code migration. Results: Multiple versioned code hosting services were used to develop distinct ImageJS modules to illustrate its amenability to collaborative deployment without compromise of reproducibility or provenance. The illustrative examples include modules for image segmentation, feature extraction, and filtering. The deployment of image analysis by code migration is in sharp contrast with the more conventional, heavier, and less safe reliance on data transfer. Accordingly, code and data are loaded into the browser by exactly the same script tag loading mechanism, which offers a number of interesting applications that would be hard to attain with more conventional platforms, such as NIH's popular ImageJ application. Conclusions: The modern web browser was found to be advantageous for image bioinformatics in both the research and clinical environments. This conclusion reflects advantages in deployment scalability and analysis reproducibility, as well as the critical ability to deliver advanced computational statistical procedures machines where access to sensitive data is controlled, that is, without local “download and installation”. PMID:22934238
Almeida, Jonas S; Iriabho, Egiebade E; Gorrepati, Vijaya L; Wilkinson, Sean R; Grüneberg, Alexander; Robbins, David E; Hackney, James R
2012-01-01
Image bioinformatics infrastructure typically relies on a combination of server-side high-performance computing and client desktop applications tailored for graphic rendering. On the server side, matrix manipulation environments are often used as the back-end where deployment of specialized analytical workflows takes place. However, neither the server-side nor the client-side desktop solution, by themselves or combined, is conducive to the emergence of open, collaborative, computational ecosystems for image analysis that are both self-sustained and user driven. ImageJS was developed as a browser-based webApp, untethered from a server-side backend, by making use of recent advances in the modern web browser such as a very efficient compiler, high-end graphical rendering capabilities, and I/O tailored for code migration. Multiple versioned code hosting services were used to develop distinct ImageJS modules to illustrate its amenability to collaborative deployment without compromise of reproducibility or provenance. The illustrative examples include modules for image segmentation, feature extraction, and filtering. The deployment of image analysis by code migration is in sharp contrast with the more conventional, heavier, and less safe reliance on data transfer. Accordingly, code and data are loaded into the browser by exactly the same script tag loading mechanism, which offers a number of interesting applications that would be hard to attain with more conventional platforms, such as NIH's popular ImageJ application. The modern web browser was found to be advantageous for image bioinformatics in both the research and clinical environments. This conclusion reflects advantages in deployment scalability and analysis reproducibility, as well as the critical ability to deliver advanced computational statistical procedures machines where access to sensitive data is controlled, that is, without local "download and installation".
2011-01-01
Background Image segmentation is a crucial step in quantitative microscopy that helps to define regions of tissues, cells or subcellular compartments. Depending on the degree of user interactions, segmentation methods can be divided into manual, automated or semi-automated approaches. 3D image stacks usually require automated methods due to their large number of optical sections. However, certain applications benefit from manual or semi-automated approaches. Scenarios include the quantification of 3D images with poor signal-to-noise ratios or the generation of so-called ground truth segmentations that are used to evaluate the accuracy of automated segmentation methods. Results We have developed Gebiss; an ImageJ plugin for the interactive segmentation, visualisation and quantification of 3D microscopic image stacks. We integrated a variety of existing plugins for threshold-based segmentation and volume visualisation. Conclusions We demonstrate the application of Gebiss to the segmentation of nuclei in live Drosophila embryos and the quantification of neurodegeneration in Drosophila larval brains. Gebiss was developed as a cross-platform ImageJ plugin and is freely available on the web at http://imaging.bii.a-star.edu.sg/projects/gebiss/. PMID:21668958
Rajyalakshmi, R.; Prakash, Winston D.; Ali, Mohammad Javed; Naik, Milind N.
2017-01-01
Purpose: To assess the reliability and repeatability of periorbital biometric measurements using ImageJ software and to assess if the horizontal visible iris diameter (HVID) serves as a reliable scale for facial measurements. Methods: This study was a prospective, single-blind, comparative study. Two clinicians performed 12 periorbital measurements on 100 standardised face photographs. Each individual’s HVID was determined by Orbscan IIz and used as a scale for measurements using ImageJ software. All measurements were repeated using the ‘average’ HVID of the study population as a measurement scale. Intraclass correlation coefficient (ICC) and Pearson product-moment coefficient were used as statistical tests to analyse the data. Results: The range of ICC for intra- and interobserver variability was 0.79–0.99 and 0.86–0.99, respectively. Test-retest reliability ranged from 0.66–1.0 to 0.77–0.98, respectively. When average HVID of the study population was used as scale, ICC ranged from 0.83 to 0.99, and the test-retest reliability ranged from 0.83 to 0.96 and the measurements correlated well with recordings done with individual Orbscan HVID measurements. Conclusion: Periorbital biometric measurements using ImageJ software are reproducible and repeatable. Average HVID of the population as measured by Orbscan is a reliable scale for facial measurements. PMID:29403183
Young, Helen T M; Carr, Norman J; Green, Bryan; Tilley, Charles; Bhargava, Vidhi; Pearce, Neil
2013-08-01
To compare the accuracy of eyeball estimates of the Ki-67 proliferation index (PI) with formal counting of 2000 cells as recommend by the Royal College of Pathologists. Sections from gastroenteropancreatic neuroendocrine tumours were immunostained for Ki-67. PI was calculated using three methods: (1) a manual tally count of 2000 cells from the area of highest nuclear labelling using a microscope eyepiece graticule; (2) eyeball estimates made by four pathologists within the same area of highest nuclear labelling; and (3) image analysis of microscope photographs taken from this area using the ImageJ 'cell counter' tool. ImageJ analysis was considered the gold standard for comparison. Levels of agreement between methods were evaluated using Bland-Altman plots. Agreement between the manual tally and ImageJ assessments was very high at low PIs. Agreement between eyeball assessments and ImageJ analysis varied between pathologists. Where data for low PIs alone were analysed, there was a moderate level of agreement between pathologists' estimates and the gold standard, but when all data were included, agreement was poor. Manual tally counts of 2000 cells exhibited similar levels of accuracy to the gold standard, especially at low PIs. Eyeball estimates were significantly less accurate than the gold standard. This suggests that tumour grades may be misclassified by eyeballing and that formal tally counting of positive cells produces more reliable results. Further studies are needed to identify accurate clinically appropriate ways of calculating.
Clock Scan Protocol for Image Analysis: ImageJ Plugins.
Dobretsov, Maxim; Petkau, Georg; Hayar, Abdallah; Petkau, Eugen
2017-06-19
The clock scan protocol for image analysis is an efficient tool to quantify the average pixel intensity within, at the border, and outside (background) a closed or segmented convex-shaped region of interest, leading to the generation of an averaged integral radial pixel-intensity profile. This protocol was originally developed in 2006, as a visual basic 6 script, but as such, it had limited distribution. To address this problem and to join similar recent efforts by others, we converted the original clock scan protocol code into two Java-based plugins compatible with NIH-sponsored and freely available image analysis programs like ImageJ or Fiji ImageJ. Furthermore, these plugins have several new functions, further expanding the range of capabilities of the original protocol, such as analysis of multiple regions of interest and image stacks. The latter feature of the program is especially useful in applications in which it is important to determine changes related to time and location. Thus, the clock scan analysis of stacks of biological images may potentially be applied to spreading of Na + or Ca ++ within a single cell, as well as to the analysis of spreading activity (e.g., Ca ++ waves) in populations of synaptically-connected or gap junction-coupled cells. Here, we describe these new clock scan plugins and show some examples of their applications in image analysis.
ImageJ: A Free, Easy, and Reliable Method to Measure Leg Ulcers Using Digital Pictures.
Aragón-Sánchez, Javier; Quintana-Marrero, Yurena; Aragón-Hernández, Cristina; Hernández-Herero, María José
2017-12-01
Wound measurement to document the healing course of chronic leg ulcers has an important role in the management of these patients. Digital cameras in smartphones are readily available and easy to use, and taking pictures of wounds is becoming a routine in specialized departments. Analyzing digital pictures with appropriate software provides clinicians a quick, clean, and easy-to-use tool for measuring wound area. A set of 25 digital pictures of plain foot and leg ulcers was the basis of this study. Photographs were taken placing a ruler next to the wound in parallel with the healthy skin with the iPhone 6S (Apple Inc, Cupertino, CA), which has a camera of 12 megapixels using the flash. The digital photographs were visualized with ImageJ 1.45s freeware (National Institutes of Health, Rockville, MD; http://imagej.net/ImageJ ). Wound area measurement was carried out by 4 raters: head of the department, wound care nurse, physician, and medical student. We assessed intra- and interrater reliability using the interclass correlation coefficient. To determine intraobserver reliability, 2 of the raters repeated the measurement of the set 1 week after the first reading. The interrater model displayed an interclass correlation coefficient of 0.99 with 95% confidence interval of 0.999 to 1.000, showing excellent reliability. The intrarater model of both examiners showed excellent reliability. In conclusion, analyzing digital images of leg ulcers with ImageJ estimates wound area with excellent reliability. This method provides a free, rapid, and accurate way to measure wounds and could routinely be used to document wound healing in daily clinical practice.
Using quantum filters to process images of diffuse axonal injury
NASA Astrophysics Data System (ADS)
Pineda Osorio, Mateo
2014-06-01
Some images corresponding to a diffuse axonal injury (DAI) are processed using several quantum filters such as Hermite Weibull and Morse. Diffuse axonal injury is a particular, common and severe case of traumatic brain injury (TBI). DAI involves global damage on microscopic scale of brain tissue and causes serious neurologic abnormalities. New imaging techniques provide excellent images showing cellular damages related to DAI. Said images can be processed with quantum filters, which accomplish high resolutions of dendritic and axonal structures both in normal and pathological state. Using the Laplacian operators from the new quantum filters, excellent edge detectors for neurofiber resolution are obtained. Image quantum processing of DAI images is made using computer algebra, specifically Maple. Quantum filter plugins construction is proposed as a future research line, which can incorporated to the ImageJ software package, making its use simpler for medical personnel.
Seamon, Bryant A.; Teixeira, Carla; Ismail, Catheeja
2016-01-01
Background. Quantitative diagnostic ultrasound imaging has been proposed as a method of estimating muscle quality using measures of echogenicity. The Rectangular Marquee Tool (RMT) and the Free Hand Tool (FHT) are two types of editing features used in Photoshop and ImageJ for determining a region of interest (ROI) within an ultrasound image. The primary objective of this study is to determine the intrarater and interrater reliability of Photoshop and ImageJ for the estimate of muscle tissue echogenicity in older adults via grayscale histogram analysis. The secondary objective is to compare the mean grayscale values obtained using both the RMT and FHT methods across both image analysis platforms. Methods. This cross-sectional observational study features 18 community-dwelling men (age = 61.5 ± 2.32 years). Longitudinal views of the rectus femoris were captured using B-mode ultrasound. The ROI for each scan was selected by 2 examiners using the RMT and FHT methods from each software program. Their reliability is assessed using intraclass correlation coefficients (ICCs) and the standard error of the measurement (SEM). Measurement agreement for these values is depicted using Bland-Altman plots. A paired t-test is used to determine mean differences in echogenicity expressed as grayscale values using the RMT and FHT methods to select the post-image acquisition ROI. The degree of association among ROI selection methods and image analysis platforms is analyzed using the coefficient of determination (R2). Results. The raters demonstrated excellent intrarater and interrater reliability using the RMT and FHT methods across both platforms (lower bound 95% CI ICC = .97–.99, p < .001). Mean differences between the echogenicity estimates obtained with the RMT and FHT methods was .87 grayscale levels (95% CI [.54–1.21], p < .0001) using data obtained with both programs. The SEM for Photoshop was .97 and 1.05 grayscale levels when using the RMT and FHT ROI selection methods, respectively. Comparatively, the SEM values were .72 and .81 grayscale levels, respectively, when using the RMT and FHT ROI selection methods in ImageJ. Uniform coefficients of determination (R2 = .96–.99, p < .001) indicate strong positive associations among the grayscale histogram analysis measurement conditions independent of the ROI selection methods and imaging platform. Conclusion. Our method for evaluating muscle echogenicity demonstrated a high degree of intrarater and interrater reliability using both the RMT and FHT methods across 2 common image analysis platforms. The minimal measurement error exhibited by the examiners demonstrates that the ROI selection methods used with Photoshop and ImageJ are suitable for the post-acquisition image analysis of tissue echogenicity in older adults. PMID:26925339
Nema, Shubham; Hasan, Whidul; Bhargava, Anamika; Bhargava, Yogesh
2016-09-15
Behavioural neuroscience relies on software driven methods for behavioural assessment, but the field lacks cost-effective, robust, open source software for behavioural analysis. Here we propose a novel method which we called as ZebraTrack. It includes cost-effective imaging setup for distraction-free behavioural acquisition, automated tracking using open-source ImageJ software and workflow for extraction of behavioural endpoints. Our ImageJ algorithm is capable of providing control to users at key steps while maintaining automation in tracking without the need for the installation of external plugins. We have validated this method by testing novelty induced anxiety behaviour in adult zebrafish. Our results, in agreement with established findings, showed that during state-anxiety, zebrafish showed reduced distance travelled, increased thigmotaxis and freezing events. Furthermore, we proposed a method to represent both spatial and temporal distribution of choice-based behaviour which is currently not possible to represent using simple videograms. ZebraTrack method is simple and economical, yet robust enough to give results comparable with those obtained from costly proprietary software like Ethovision XT. We have developed and validated a novel cost-effective method for behavioural analysis of adult zebrafish using open-source ImageJ software. Copyright © 2016 Elsevier B.V. All rights reserved.
AGScan: a pluggable microarray image quantification software based on the ImageJ library.
Cathelin, R; Lopez, F; Klopp, Ch
2007-01-15
Many different programs are available to analyze microarray images. Most programs are commercial packages, some are free. In the latter group only few propose automatic grid alignment and batch mode. More often than not a program implements only one quantification algorithm. AGScan is an open source program that works on all major platforms. It is based on the ImageJ library [Rasband (1997-2006)] and offers a plug-in extension system to add new functions to manipulate images, align grid and quantify spots. It is appropriate for daily laboratory use and also as a framework for new algorithms. The program is freely distributed under X11 Licence. The install instructions can be found in the user manual. The software can be downloaded from http://mulcyber.toulouse.inra.fr/projects/agscan/. The questions and plug-ins can be sent to the contact listed below.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daniela Ushizima, Wes Bethel
Quant-CT is currently a plugin to ImageJ, designed as a Java-class that provides control mechanism for the user to choose volumes of interest within porous material, followed by the selection of image subsamples for automated tuning of parameters for filters and classifiers, and finally measurement of material geometry, porosity, and visualization. Denoising is mandatory before any image interpretation, and we implemented a new 3D java code that performs bilateral filtering of data. Segmentation of the dense material is essential before any quantifications about geological sample structure, and we invented new schemes to deal with over segmentation when using statistical regionmore » merging algorithm to pull out grains that compose imaged material. It make uses of ImageJ API and other standard and thirty-party APIs. Quant-CT conception started in 2011 under Scidac-e sponsor, and details of the first prototype were documented in publications below. While it is used right now for microtomography images, it can potentially be used by anybody with 3D image data obtained by experiment or produced by simulation.« less
Development and validation of an open source quantification tool for DSC-MRI studies.
Gordaliza, P M; Mateos-Pérez, J M; Montesinos, P; Guzmán-de-Villoria, J A; Desco, M; Vaquero, J J
2015-03-01
This work presents the development of an open source tool for the quantification of dynamic susceptibility-weighted contrast-enhanced (DSC) perfusion studies. The development of this tool is motivated by the lack of open source tools implemented on open platforms to allow external developers to implement their own quantification methods easily and without the need of paying for a development license. This quantification tool was developed as a plugin for the ImageJ image analysis platform using the Java programming language. A modular approach was used in the implementation of the components, in such a way that the addition of new methods can be done without breaking any of the existing functionalities. For the validation process, images from seven patients with brain tumors were acquired and quantified with the presented tool and with a widely used clinical software package. The resulting perfusion parameters were then compared. Perfusion parameters and the corresponding parametric images were obtained. When no gamma-fitting is used, an excellent agreement with the tool used as a gold-standard was obtained (R(2)>0.8 and values are within 95% CI limits in Bland-Altman plots). An open source tool that performs quantification of perfusion studies using magnetic resonance imaging has been developed and validated using a clinical software package. It works as an ImageJ plugin and the source code has been published with an open source license. Copyright © 2015 Elsevier Ltd. All rights reserved.
FLIM data analysis of NADH and Tryptophan autofluorescence in prostate cancer cells
NASA Astrophysics Data System (ADS)
O'Melia, Meghan J.; Wallrabe, Horst; Svindrych, Zdenek; Rehman, Shagufta; Periasamy, Ammasi
2016-03-01
Fluorescence lifetime imaging microscopy (FLIM) is one of the most sensitive techniques to measure metabolic activity in living cells, tissues and whole animals. We used two- and three-photon fluorescence excitation together with time-correlated single photon counting (TCSPC) to acquire FLIM signals from normal and prostate cancer cell lines. FLIM requires complex data fitting and analysis; we explored different ways to analyze the data to match diverse cellular morphologies. After non-linear least square fitting of the multi-photon TCSPC images by the SPCImage software (Becker & Hickl), all image data are exported and further processed in ImageJ. Photon images provide morphological, NAD(P)H signal-based autofluorescent features, for which regions of interest (ROIs) are created. Applying these ROIs to all image data parameters with a custom ImageJ macro, generates a discrete, ROI specific database. A custom Excel (Microsoft) macro further analyzes the data with charts and statistics. Applying this highly automated assay we compared normal and cancer prostate cell lines with respect to their glycolytic activity by analyzing the NAD(P)H-bound fraction (a2%), NADPH/NADH ratio and efficiency of energy transfer (E%) for Tryptophan (Trp). Our results show that this assay is able to differentiate the effects of glucose stimulation and Doxorubicin in these prostate cell lines by tracking the changes in a2% of NAD(P)H, NADPH/NADH ratio and the changes in Trp E%. The ability to isolate a large, ROI-based data set, reflecting the heterogeneous cellular environment and highlighting even subtle changes -- rather than whole cell averages - makes this assay particularly valuable.
A new ImageJ plug-in "ActogramJ" for chronobiological analyses.
Schmid, Benjamin; Helfrich-Förster, Charlotte; Yoshii, Taishi
2011-10-01
While the rapid development of personal computers and high-throughput recording systems for circadian rhythms allow chronobiologists to produce huge amounts of data, the software to analyze them often lags behind. Here, we announce newly developed chronobiology software that is easy to use, compatible with many different systems, and freely available. Our system can perform the most frequently used analyses: actogram drawing, periodogram analysis, and waveform analysis. The software is distributed as a pure Java plug-in for ImageJ and so works on the 3 main operating systems: Linux, Macintosh, and Windows. We believe that this free software raises the speed of data analyses and makes studying chronobiology accessible to newcomers. © 2011 The Author(s)
FibrilJ: ImageJ plugin for fibrils' diameter and persistence length determination
NASA Astrophysics Data System (ADS)
Sokolov, P. A.; Belousov, M. V.; Bondarev, S. A.; Zhouravleva, G. A.; Kasyanenko, N. A.
2017-05-01
Application of microscopy to evaluate the morphology and size of filamentous proteins and amyloids requires new and creative approaches to simplify and automate the image processing. The estimation of mean values of fibrils diameter, length and bending stiffness on micrographs is a major challenge. For this purpose we developed an open-source FibrilJ plugin for the ImageJ/FiJi program. It automatically recognizes the fibrils on the surface of a mica, silicon, gold or formvar film and further analyzes them to calculate the distribution of fibrils by diameters, lengths and persistence lengths. The plugin has been validated by the processing of TEM images of fibrils formed by Sup35NM yeast protein and artificially created images of rod-shape objects with predefined parameters. Novel data obtained by SEM for Sup35NM protein fibrils immobilized on silicon and gold substrates are also presented and analyzed.
Müller, Marcel; Mönkemöller, Viola; Hennig, Simon; Hübner, Wolfgang; Huser, Thomas
2016-01-01
Super-resolved structured illumination microscopy (SR-SIM) is an important tool for fluorescence microscopy. SR-SIM microscopes perform multiple image acquisitions with varying illumination patterns, and reconstruct them to a super-resolved image. In its most frequent, linear implementation, SR-SIM doubles the spatial resolution. The reconstruction is performed numerically on the acquired wide-field image data, and thus relies on a software implementation of specific SR-SIM image reconstruction algorithms. We present fairSIM, an easy-to-use plugin that provides SR-SIM reconstructions for a wide range of SR-SIM platforms directly within ImageJ. For research groups developing their own implementations of super-resolution structured illumination microscopy, fairSIM takes away the hurdle of generating yet another implementation of the reconstruction algorithm. For users of commercial microscopes, it offers an additional, in-depth analysis option for their data independent of specific operating systems. As a modular, open-source solution, fairSIM can easily be adapted, automated and extended as the field of SR-SIM progresses. PMID:26996201
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herchko, S; Ding, G
2016-06-15
Purpose: To develop an accurate, straightforward, and user-independent method for performing light versus radiation field coincidence quality assurance utilizing EPID images, a simple phantom made of readily-accessible materials, and a free software program. Methods: A simple phantom consisting of a blocking tray, graph paper, and high-density wire was constructed. The phantom was used to accurately set the size of a desired light field and imaged on the electronic portal imaging device (EPID). A macro written for use in ImageJ, a free image processing software, was then use to determine the radiation field size utilizing the high density wires on themore » phantom for a pixel to distance calibration. The macro also performs an analysis on the measured radiation field utilizing the tolerances recommended in the AAPM Task Group #142. To verify the accuracy of this method, radiochromic film was used to qualitatively demonstrate agreement between the film and EPID results, and an additional ImageJ macro was used to quantitatively compare the radiation field sizes measured both with the EPID and film images. Results: The results of this technique were benchmarked against film measurements, which have been the gold standard for testing light versus radiation field coincidence. The agreement between this method and film measurements were within 0.5 mm. Conclusion: Due to the operator dependency associated with tracing light fields and measuring radiation fields by hand when using film, this method allows for a more accurate comparison between the light and radiation fields with minimal operator dependency. Removing the need for radiographic or radiochromic film also eliminates a reoccurring cost and increases procedural efficiency.« less
Lunar Regolith Particle Shape Analysis
NASA Technical Reports Server (NTRS)
Kiekhaefer, Rebecca; Hardy, Sandra; Rickman, Douglas; Edmunson, Jennifer
2013-01-01
Future engineering of structures and equipment on the lunar surface requires significant understanding of particle characteristics of the lunar regolith. Nearly all sediment characteristics are influenced by particle shape; therefore a method of quantifying particle shape is useful both in lunar and terrestrial applications. We have created a method to quantify particle shape, specifically for lunar regolith, using image processing. Photomicrographs of thin sections of lunar core material were obtained under reflected light. Three photomicrographs were analyzed using ImageJ and MATLAB. From the image analysis measurements for area, perimeter, Feret diameter, orthogonal Feret diameter, Heywood factor, aspect ratio, sieve diameter, and sieve number were recorded. Probability distribution functions were created from the measurements of Heywood factor and aspect ratio.
Choudhry, Priya
2016-01-01
Counting cells and colonies is an integral part of high-throughput screens and quantitative cellular assays. Due to its subjective and time-intensive nature, manual counting has hindered the adoption of cellular assays such as tumor spheroid formation in high-throughput screens. The objective of this study was to develop an automated method for quick and reliable counting of cells and colonies from digital images. For this purpose, I developed an ImageJ macro Cell Colony Edge and a CellProfiler Pipeline Cell Colony Counting, and compared them to other open-source digital methods and manual counts. The ImageJ macro Cell Colony Edge is valuable in counting cells and colonies, and measuring their area, volume, morphology, and intensity. In this study, I demonstrate that Cell Colony Edge is superior to other open-source methods, in speed, accuracy and applicability to diverse cellular assays. It can fulfill the need to automate colony/cell counting in high-throughput screens, colony forming assays, and cellular assays. PMID:26848849
McKenzie, Barbara; Kay, Graeme; Matthews, Kerr H; Knott, Rachel M; Cairns, Donald
2015-07-25
A modified hen's egg chorioallantoic membrane (HET-CAM) test has been developed, combining ImageJ analysis with Adobe(®) Photoshop(®). The irritation potential of an ophthalmic medicine can be quantified using this method, by monitoring damage to blood vessels. The evaluation of cysteamine containing hyaluronate gel is reported. The results demonstrated that the novel gel formulation is non-irritant to the ocular tissues, in line with saline solution (negative control). In conclusion, the modification of the established HET-CAM test can quantify the damage to minute blood vessels. These results offer the possibility to formulate cysteamine in an ocular applicable gel formulation. Copyright © 2015 Elsevier B.V. All rights reserved.
Image enhancement using MCNP5 code and MATLAB in neutron radiography.
Tharwat, Montaser; Mohamed, Nader; Mongy, T
2014-07-01
This work presents a method that can be used to enhance the neutron radiography (NR) image for objects with high scattering materials like hydrogen, carbon and other light materials. This method used Monte Carlo code, MCNP5, to simulate the NR process and get the flux distribution for each pixel of the image and determines the scattered neutron distribution that caused image blur, and then uses MATLAB to subtract this scattered neutron distribution from the initial image to improve its quality. This work was performed before the commissioning of digital NR system in Jan. 2013. The MATLAB enhancement method is quite a good technique in the case of static based film neutron radiography, while in neutron imaging (NI) technique, image enhancement and quantitative measurement were efficient by using ImageJ software. The enhanced image quality and quantitative measurements were presented in this work. Copyright © 2014 Elsevier Ltd. All rights reserved.
Cellular Consequences of Telomere Shortening in Histologically Normal Breast Tissues
2013-09-01
using the open source, JAVA -based image analysis software package ImageJ (http://rsb.info.nih.gov/ij/) and a custom designed plugin (“Telometer...Tabulated data were stored in a MySQL (http://www.mysql.com) database and viewed through Microsoft Access (Microsoft Corp.). Statistical Analysis For
NASA Astrophysics Data System (ADS)
Seeto, Wen Jun; Lipke, Elizabeth Ann
2016-03-01
Tracking of rolling cells via in vitro experiment is now commonly performed using customized computer programs. In most cases, two critical challenges continue to limit analysis of cell rolling data: long computation times due to the complexity of tracking algorithms and difficulty in accurately correlating a given cell with itself from one frame to the next, which is typically due to errors caused by cells that either come close in proximity to each other or come in contact with each other. In this paper, we have developed a sophisticated, yet simple and highly effective, rolling cell tracking system to address these two critical problems. This optical cell tracking analysis (OCTA) system first employs ImageJ for cell identification in each frame of a cell rolling video. A custom MATLAB code was written to use the geometric and positional information of all cells as the primary parameters for matching each individual cell with itself between consecutive frames and to avoid errors when tracking cells that come within close proximity to one another. Once the cells are matched, rolling velocity can be obtained for further analysis. The use of ImageJ for cell identification eliminates the need for high level MATLAB image processing knowledge. As a result, only fundamental MATLAB syntax is necessary for cell matching. OCTA has been implemented in the tracking of endothelial colony forming cell (ECFC) rolling under shear. The processing time needed to obtain tracked cell data from a 2 min ECFC rolling video recorded at 70 frames per second with a total of over 8000 frames is less than 6 min using a computer with an Intel® Core™ i7 CPU 2.80 GHz (8 CPUs). This cell tracking system benefits cell rolling analysis by substantially reducing the time required for post-acquisition data processing of high frame rate video recordings and preventing tracking errors when individual cells come in close proximity to one another.
Global gray-level thresholding based on object size.
Ranefall, Petter; Wählby, Carolina
2016-04-01
In this article, we propose a fast and robust global gray-level thresholding method based on object size, where the selection of threshold level is based on recall and maximum precision with regard to objects within a given size interval. The method relies on the component tree representation, which can be computed in quasi-linear time. Feature-based segmentation is especially suitable for biomedical microscopy applications where objects often vary in number, but have limited variation in size. We show that for real images of cell nuclei and synthetic data sets mimicking fluorescent spots the proposed method is more robust than all standard global thresholding methods available for microscopy applications in ImageJ and CellProfiler. The proposed method, provided as ImageJ and CellProfiler plugins, is simple to use and the only required input is an interval of the expected object sizes. © 2016 International Society for Advancement of Cytometry. © 2016 International Society for Advancement of Cytometry.
Bergmeister, Konstantin D; Gröger, Marion; Aman, Martin; Willensdorfer, Anna; Manzano-Szalai, Krisztina; Salminger, Stefan; Aszmann, Oskar C
2016-08-01
Skeletal muscle consists of different fiber types which adapt to exercise, aging, disease, or trauma. Here we present a protocol for fast staining, automatic acquisition, and quantification of fiber populations with ImageJ. Biceps and lumbrical muscles were harvested from Sprague-Dawley rats. Quadruple immunohistochemical staining was performed on single sections using antibodies against myosin heavy chains and secondary fluorescent antibodies. Slides were scanned automatically with a slide scanner. Manual and automatic analyses were performed and compared statistically. The protocol provided rapid and reliable staining for automated image acquisition. Analyses between manual and automatic data indicated Pearson correlation coefficients for biceps of 0.645-0.841 and 0.564-0.673 for lumbrical muscles. Relative fiber populations were accurate to a degree of ± 4%. This protocol provides a reliable tool for quantification of muscle fiber populations. Using freely available software, it decreases the required time to analyze whole muscle sections. Muscle Nerve 54: 292-299, 2016. © 2016 Wiley Periodicals, Inc.
Data Processing of LAPAN-A3 Thermal Imager
NASA Astrophysics Data System (ADS)
Hartono, R.; Hakim, P. R.; Syafrudin, AH
2018-04-01
As an experimental microsatellite, LAPAN-A3/IPB satellite has an experimental thermal imager, which is called as micro-bolometer, to observe earth surface temperature for horizon observation. The imager data is transmitted from satellite to ground station by S-band video analog signal transmission, and then processed by ground station to become sequence of 8-bit enhanced and contrasted images. Data processing of LAPAN-A3/IPB thermal imager is more difficult than visual digital camera, especially for mosaic and classification purpose. This research aims to describe simple mosaic and classification process of LAPAN-A3/IPB thermal imager based on several videos data produced by the imager. The results show that stitching using Adobe Photoshop produces excellent result but can only process small area, while manual approach using ImageJ software can produce a good result but need a lot of works and time consuming. The mosaic process using image cross-correlation by Matlab offers alternative solution, which can process significantly bigger area in significantly shorter time processing. However, the quality produced is not as good as mosaic images of the other two methods. The simple classifying process that has been done shows that the thermal image can classify three distinct objects, i.e.: clouds, sea, and land surface. However, the algorithm fail to classify any other object which might be caused by distortions in the images. All of these results can be used as reference for development of thermal imager in LAPAN-A4 satellite.
Automated image analysis for quantification of reactive oxygen species in plant leaves.
Sekulska-Nalewajko, Joanna; Gocławski, Jarosław; Chojak-Koźniewska, Joanna; Kuźniak, Elżbieta
2016-10-15
The paper presents an image processing method for the quantitative assessment of ROS accumulation areas in leaves stained with DAB or NBT for H 2 O 2 and O 2 - detection, respectively. Three types of images determined by the combination of staining method and background color are considered. The method is based on the principle of supervised machine learning with manually labeled image patterns used for training. The method's algorithm is developed as a JavaScript macro in the public domain Fiji (ImageJ) environment. It allows to select the stained regions of ROS-mediated histochemical reactions, subsequently fractionated according to the weak, medium and intense staining intensity and thus ROS accumulation. It also evaluates total leaf blade area. The precision of ROS accumulation area detection is validated by the Dice Similarity Coefficient in the case of manual patterns. The proposed framework reduces the computation complexity, once prepared, requires less image processing expertise than the competitive methods and represents a routine quantitative imaging assay for a general histochemical image classification. Copyright © 2016 Elsevier Inc. All rights reserved.
Easy Leaf Area: Automated digital image analysis for rapid and accurate measurement of leaf area.
Easlon, Hsien Ming; Bloom, Arnold J
2014-07-01
Measurement of leaf areas from digital photographs has traditionally required significant user input unless backgrounds are carefully masked. Easy Leaf Area was developed to batch process hundreds of Arabidopsis rosette images in minutes, removing background artifacts and saving results to a spreadsheet-ready CSV file. • Easy Leaf Area uses the color ratios of each pixel to distinguish leaves and calibration areas from their background and compares leaf pixel counts to a red calibration area to eliminate the need for camera distance calculations or manual ruler scale measurement that other software methods typically require. Leaf areas estimated by this software from images taken with a camera phone were more accurate than ImageJ estimates from flatbed scanner images. • Easy Leaf Area provides an easy-to-use method for rapid measurement of leaf area and nondestructive estimation of canopy area from digital images.
Downie, Laura E; Naranjo Golborne, Cecilia; Chen, Merry; Ho, Ngoc; Hoac, Cam; Liyanapathirana, Dasun; Luo, Carol; Wu, Ruo Bing; Chinnery, Holly R
2018-06-01
Our aim was to compare regeneration of the sub-basal nerve plexus (SBNP) and superficial nerve terminals (SNT) following corneal epithelial injury. We also sought to compare agreement when quantifying nerve parameters using different image analysis techniques. Anesthetized, female C57BL/6 mice received central 1-mm corneal epithelial abrasions. Four-weeks post-injury, eyes were enucleated and processed for PGP9.5 to visualize the corneal nerves using wholemount immunofluorescence staining and confocal microscopy. The percentage area of the SBNP and SNT were quantified using: ImageJ automated thresholds, ImageJ manual thresholds and manual tracings in NeuronJ. Nerve sum length was quantified using NeuronJ and Imaris. Agreement between methods was considered with Bland-Altman analyses. Four-weeks post-injury, the sum length of nerve fibers in the SBNP, but not the SNT, was reduced compared with naïve eyes. In the periphery, but not central cornea, of both naïve and injured eyes, nerve fiber lengths in the SBNP and SNT were strongly correlated. For quantifying SBNP nerve axon area, all image analysis methods were highly correlated. In the SNT, there was poor correlation between manual methods and auto-thresholding, with a trend towards underestimating nerve fiber area using auto-thresholding when higher proportions of nerve fibers were present. In conclusion, four weeks after superficial corneal injury, there is differential recovery of epithelial nerve axons; SBNP sum length is reduced, however the sum length of SNTs is similar to naïve eyes. Care should be taken when selecting image analysis methods to compare nerve parameters in different depths of the corneal epithelium due to differences in background autofluorescence. Copyright © 2018 Elsevier Ltd. All rights reserved.
Shu, Jie; Dolman, G E; Duan, Jiang; Qiu, Guoping; Ilyas, Mohammad
2016-04-27
Colour is the most important feature used in quantitative immunohistochemistry (IHC) image analysis; IHC is used to provide information relating to aetiology and to confirm malignancy. Statistical modelling is a technique widely used for colour detection in computer vision. We have developed a statistical model of colour detection applicable to detection of stain colour in digital IHC images. Model was first trained by massive colour pixels collected semi-automatically. To speed up the training and detection processes, we removed luminance channel, Y channel of YCbCr colour space and chose 128 histogram bins which is the optimal number. A maximum likelihood classifier is used to classify pixels in digital slides into positively or negatively stained pixels automatically. The model-based tool was developed within ImageJ to quantify targets identified using IHC and histochemistry. The purpose of evaluation was to compare the computer model with human evaluation. Several large datasets were prepared and obtained from human oesophageal cancer, colon cancer and liver cirrhosis with different colour stains. Experimental results have demonstrated the model-based tool achieves more accurate results than colour deconvolution and CMYK model in the detection of brown colour, and is comparable to colour deconvolution in the detection of pink colour. We have also demostrated the proposed model has little inter-dataset variations. A robust and effective statistical model is introduced in this paper. The model-based interactive tool in ImageJ, which can create a visual representation of the statistical model and detect a specified colour automatically, is easy to use and available freely at http://rsb.info.nih.gov/ij/plugins/ihc-toolbox/index.html . Testing to the tool by different users showed only minor inter-observer variations in results.
Flavel, Richard J; Guppy, Chris N; Rabbi, Sheikh M R; Young, Iain M
2017-01-01
The objective of this study was to develop a flexible and free image processing and analysis solution, based on the Public Domain ImageJ platform, for the segmentation and analysis of complex biological plant root systems in soil from x-ray tomography 3D images. Contrasting root architectures from wheat, barley and chickpea root systems were grown in soil and scanned using a high resolution micro-tomography system. A macro (Root1) was developed that reliably identified with good to high accuracy complex root systems (10% overestimation for chickpea, 1% underestimation for wheat, 8% underestimation for barley) and provided analysis of root length and angle. In-built flexibility allowed the user interaction to (a) amend any aspect of the macro to account for specific user preferences, and (b) take account of computational limitations of the platform. The platform is free, flexible and accurate in analysing root system metrics.
NASA Astrophysics Data System (ADS)
Alshipli, Marwan; Kabir, Norlaili A.
2017-05-01
Computed tomography (CT) employs X-ray radiation to create cross-sectional images. Dual-energy CT acquisition includes the images acquired from an alternating voltage of X-ray tube: a low- and a high-peak kilovoltage. The main objective of this study is to determine the best slice thickness that reduces image noise with adequate diagnostic information using dual energy CT head protocol. The study used the ImageJ software and statistical analyses to aid the medical image analysis of dual-energy CT. In this study, ImageJ software and F-test were utilised as the combination methods to analyse DICOM CT images. They were used to investigate the effect of slice thickness on noise and visibility in dual-energy CT head protocol images. Catphan-600 phantom was scanned at different slice thickness values;.6, 1, 2, 3, 4, 5 and 6 mm, then quantitative analyses were carried out. The DECT operated in helical mode with another fixed scan parameter values. Based on F-test statistical analyses, image noise at 0.6, 1, and 2 mm were significantly different compared to the other images acquired at slice thickness of 3, 4, 5, and 6 mm. However, no significant differences of image noise were observed at 3, 4, 5, and 6 mm. As a result, better diagnostic image value, image visibility, and lower image noise in dual-energy CT head protocol was observed at a slice thickness of 3 mm.
Muscle fiber diameter assessment in cleft lip using image processing.
Khan, M F J; Little, J; Abelli, L; Mossey, P A; Autelitano, L; Nag, T C; Rubini, M
2018-04-01
To pilot investigation of muscle fiber diameter (MFD) on medial and lateral sides of the cleft in 18 infants with cleft lip with or without cleft palate (CL/P) using image processing. Formalin-fixed paraffin-embedded (FFPE) tissue samples from the medial and lateral sides of the cleft were analyzed for MFD using an image-processing program (ImageJ). For within-case comparison, a paired Student's t test was performed. For comparisons between classes, an unpaired t test was used. Image processing enabled rapid measurement of MFD with majority of fibers showing diameter between 6 and 11 μm. There was no significant difference in mean MFD between the medial and lateral sides, or between CL and CLP. However, we found a significant difference on the medial side (p = .032) between males and females. The image processing on FFPE tissues resulted in easy quantification of MFD with finding of a smaller MFD on the medial side in males suggesting possible differences in orbicularis oris (OO) muscle between the two sexes in CL that warrants replication using larger number of cases. Moreover, this finding can aid subclinical phenotyping and potentially in the restoration of the anatomy and function of the upper lip. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd. All rights reserved.
Ibrahim, Reham S; Fathy, Hoda
2018-03-30
Tracking the impact of commonly applied post-harvesting and industrial processing practices on the compositional integrity of ginger rhizome was implemented in this work. Untargeted metabolite profiling was performed using digitally-enhanced HPTLC method where the chromatographic fingerprints were extracted using ImageJ software then analysed with multivariate Principal Component Analysis (PCA) for pattern recognition. A targeted approach was applied using a new, validated, simple and fast HPTLC image analysis method for simultaneous quantification of the officially recognized markers 6-, 8-, 10-gingerol and 6-shogaol in conjunction with chemometric Hierarchical Clustering Analysis (HCA). The results of both targeted and untargeted metabolite profiling revealed that peeling, drying in addition to storage employed during processing have a great influence on ginger chemo-profile, the different forms of processed ginger shouldn't be used interchangeably. Moreover, it deemed necessary to consider the holistic metabolic profile for comprehensive evaluation of ginger during processing. Copyright © 2018. Published by Elsevier B.V.
Brown, Ryan M; Meah, Christopher J; Heath, Victoria L; Styles, Iain B; Bicknell, Roy
2016-01-01
Angiogenesis involves the generation of new blood vessels from the existing vasculature and is dependent on many growth factors and signaling events. In vivo angiogenesis is dynamic and complex, meaning assays are commonly utilized to explore specific targets for research into this area. Tube-forming assays offer an excellent overview of the molecular processes in angiogenesis. The Matrigel tube forming assay is a simple-to-implement but powerful tool for identifying biomolecules involved in angiogenesis. A detailed experimental protocol on the implementation of the assay is described in conjunction with an in-depth review of methods that can be applied to the analysis of the tube formation. In addition, an ImageJ plug-in is presented which allows automatic quantification of tube images reducing analysis times while removing user bias and subjectivity.
You, Yun-Wen; Chang, Hsun-Yun; Liao, Hua-Yang; Kao, Wei-Lun; Yen, Guo-Ji; Chang, Chi-Jen; Tsai, Meng-Hung; Shyue, Jing-Jong
2012-10-01
Based on a scanning electron microscope operated at 30 kV with a homemade specimen holder and a multiangle solid-state detector behind the sample, low-kV scanning transmission electron microscopy (STEM) is presented with subsequent electron tomography for three-dimensional (3D) volume structure. Because of the low acceleration voltage, the stronger electron-atom scattering leads to a stronger contrast in the resulting image than standard TEM, especially for light elements. Furthermore, the low-kV STEM yields less radiation damage to the specimen, hence the structure can be preserved. In this work, two-dimensional STEM images of a 1-μm-thick cell section with projection angles between ±50° were collected, and the 3D volume structure was reconstructed using the simultaneous iterative reconstructive technique algorithm with the TomoJ plugin for ImageJ, which are both public domain software. Furthermore, the cross-sectional structure was obtained with the Volume Viewer plugin in ImageJ. Although the tilting angle is constrained and limits the resulting structural resolution, slicing the reconstructed volume generated the depth profile of the thick specimen with sufficient resolution to examine cellular uptake of Au nanoparticles, and the final position of these nanoparticles inside the cell was imaged.
Acquisition and Post-Processing of Immunohistochemical Images.
Sedgewick, Jerry
2017-01-01
Augmentation of digital images is almost always a necessity in order to obtain a reproduction that matches the appearance of the original. However, that augmentation can mislead if it is done incorrectly and not within reasonable limits. When procedures are in place for insuring that originals are archived, and image manipulation steps reported, scientists not only follow good laboratory practices, but avoid ethical issues associated with post processing, and protect their labs from any future allegations of scientific misconduct. Also, when procedures are in place for correct acquisition of images, the extent of post processing is minimized or eliminated. These procedures include white balancing (for brightfield images), keeping tonal values within the dynamic range of the detector, frame averaging to eliminate noise (typically in fluorescence imaging), use of the highest bit depth when a choice is available, flatfield correction, and archiving of the image in a non-lossy format (not JPEG).When post-processing is necessary, the commonly used applications for correction include Photoshop, and ImageJ, but a free program (GIMP) can also be used. Corrections to images include scaling the bit depth to higher and lower ranges, removing color casts from brightfield images, setting brightness and contrast, reducing color noise, reducing "grainy" noise, conversion of pure colors to grayscale, conversion of grayscale to colors typically used in fluorescence imaging, correction of uneven illumination (flatfield correction), merging color images (fluorescence), and extending the depth of focus. These corrections are explained in step-by-step procedures in the chapter that follows.
Using new tools to identify eggs of Engraulis anchoita (Clupeiformes, Engraulidae).
Favero, J M; Katsuragawa, M; Zani-Teixeira, M L; Turner, J T
2014-12-26
Efficiency of the identification of eggs of Engraulis anchoita can be greatly improved by a method developed from egg measurements, using photography and the ImageJ programme, analysed by discriminant analysis using R software. © 2014 The Fisheries Society of the British Isles.
Arsenovic, Paul T; Bathula, Kranthidhar; Conway, Daniel E
2017-04-11
The LINC complex has been hypothesized to be the critical structure that mediates the transfer of mechanical forces from the cytoskeleton to the nucleus. Nesprin-2G is a key component of the LINC complex that connects the actin cytoskeleton to membrane proteins (SUN domain proteins) in the perinuclear space. These membrane proteins connect to lamins inside the nucleus. Recently, a Förster Resonance Energy Transfer (FRET)-force probe was cloned into mini-Nesprin-2G (Nesprin-TS (tension sensor)) and used to measure tension across Nesprin-2G in live NIH3T3 fibroblasts. This paper describes the process of using Nesprin-TS to measure LINC complex forces in NIH3T3 fibroblasts. To extract FRET information from Nesprin-TS, an outline of how to spectrally unmix raw spectral images into acceptor and donor fluorescent channels is also presented. Using open-source software (ImageJ), images are pre-processed and transformed into ratiometric images. Finally, FRET data of Nesprin-TS is presented, along with strategies for how to compare data across different experimental groups.
Stewart, Ethan L; Hagerty, Christina H; Mikaberidze, Alexey; Mundt, Christopher C; Zhong, Ziming; McDonald, Bruce A
2016-07-01
Zymoseptoria tritici causes Septoria tritici blotch (STB) on wheat. An improved method of quantifying STB symptoms was developed based on automated analysis of diseased leaf images made using a flatbed scanner. Naturally infected leaves (n = 949) sampled from fungicide-treated field plots comprising 39 wheat cultivars grown in Switzerland and 9 recombinant inbred lines (RIL) grown in Oregon were included in these analyses. Measures of quantitative resistance were percent leaf area covered by lesions, pycnidia size and gray value, and pycnidia density per leaf and lesion. These measures were obtained automatically with a batch-processing macro utilizing the image-processing software ImageJ. All phenotypes in both locations showed a continuous distribution, as expected for a quantitative trait. The trait distributions at both sites were largely overlapping even though the field and host environments were quite different. Cultivars and RILs could be assigned to two or more statistically different groups for each measured phenotype. Traditional visual assessments of field resistance were highly correlated with quantitative resistance measures based on image analysis for the Oregon RILs. These results show that automated image analysis provides a promising tool for assessing quantitative resistance to Z. tritici under field conditions.
Subcellular object quantification with Squassh3C and SquasshAnalyst.
Rizk, Aurélien; Mansouri, Maysam; Ballmer-Hofer, Kurt; Berger, Philipp
2015-11-01
Quantitative image analysis plays an important role in contemporary biomedical research. Squassh is a method for automatic detection, segmentation, and quantification of subcellular structures and analysis of their colocalization. Here we present the applications Squassh3C and SquasshAnalyst. Squassh3C extends the functionality of Squassh to three fluorescence channels and live-cell movie analysis. SquasshAnalyst is an interactive web interface for the analysis of Squassh3C object data. It provides segmentation image overview and data exploration, figure generation, object and image filtering, and a statistical significance test in an easy-to-use interface. The overall procedure combines the Squassh3C plug-in for the free biological image processing program ImageJ and a web application working in conjunction with the free statistical environment R, and it is compatible with Linux, MacOS X, or Microsoft Windows. Squassh3C and SquasshAnalyst are available for download at www.psi.ch/lbr/SquasshAnalystEN/SquasshAnalyst.zip.
Direct Metal Deposition of H13 Tool Steel on Copper Alloy Substrate: Parametric Investigation
NASA Astrophysics Data System (ADS)
Imran, M. Khalid; Masood, S. H.; Brandt, Milan
2015-12-01
Over the past decade, researchers have demonstrated interest in tribology and prototyping by the laser aided material deposition process. Laser aided direct metal deposition (DMD) enables the formation of a uniform clad by melting the powder to form desired component from metal powder materials. In this research H13 tool steel has been used to clad on a copper alloy substrate using DMD. The effects of laser parameters on the quality of DMD deposited clad have been investigated and acceptable processing parameters have been determined largely through trial-and-error approaches. The relationships between DMD process parameters and the product characteristics such as porosity, micro-cracks and microhardness have been analysed using scanning electron microscope (SEM), image analysis software (ImageJ) and microhardness tester. It has been found that DMD parameters such as laser power, powder mass flow rate, feed rate and focus size have an important role in clad quality and crack formation.
Measuring the apparent size of the Moon with a digital camera
NASA Astrophysics Data System (ADS)
Ellery, Adam; Hughes, Stephen
2012-09-01
The Moon appears to be much larger closer to the horizon than when higher in the sky. This is called the ‘Moon illusion’ since the observed size of the Moon is not actually larger when the Moon is just above the horizon. This paper describes a technique for verifying that the observed size of the Moon is not larger on the horizon. The technique can be performed easily in a high-school teaching environment. Moreover, the technique demonstrates the surprising fact that the observed size of the Moon is actually smaller on the horizon due to atmospheric refraction. For the purposes of this paper, several images of the Moon were taken with it close to the horizon and close to the zenith. The images were processed using a free program called ImageJ. The Moon was found to be 5.73 ± 0.04% smaller in area on the horizon then at the zenith.
Björn, Lars Olof; Li, Shaoshan
2013-10-01
Solar energy absorbed by plants results in either reflection or absorption. The latter results in photosynthesis, fluorescence, or heat. Measurements of fluorescence changes have been used for monitoring processes associated with photosynthesis. A simple method to follow changes in leaf fluorescence and leaf reflectance associated with nonphotochemical quenching and light acclimation of leaves is described. The main equipment needed consists of a green-light emitting laser pointer, a digital camera, and a personal computer equipped with the camera acquisition software and the programs ImageJ and Excel. Otherwise, only commonly available cheap materials are required.
Digital-image processing and image analysis of glacier ice
Fitzpatrick, Joan J.
2013-01-01
This document provides a methodology for extracting grain statistics from 8-bit color and grayscale images of thin sections of glacier ice—a subset of physical properties measurements typically performed on ice cores. This type of analysis is most commonly used to characterize the evolution of ice-crystal size, shape, and intercrystalline spatial relations within a large body of ice sampled by deep ice-coring projects from which paleoclimate records will be developed. However, such information is equally useful for investigating the stress state and physical responses of ice to stresses within a glacier. The methods of analysis presented here go hand-in-hand with the analysis of ice fabrics (aggregate crystal orientations) and, when combined with fabric analysis, provide a powerful method for investigating the dynamic recrystallization and deformation behaviors of bodies of ice in motion. The procedures described in this document compose a step-by-step handbook for a specific image acquisition and data reduction system built in support of U.S. Geological Survey ice analysis projects, but the general methodology can be used with any combination of image processing and analysis software. The specific approaches in this document use the FoveaPro 4 plug-in toolset to Adobe Photoshop CS5 Extended but it can be carried out equally well, though somewhat less conveniently, with software such as the image processing toolbox in MATLAB, Image-Pro Plus, or ImageJ.
Makanza, R; Zaman-Allah, M; Cairns, J E; Eyre, J; Burgueño, J; Pacheco, Ángela; Diepenbrock, C; Magorokosho, C; Tarekegne, A; Olsen, M; Prasanna, B M
2018-01-01
Grain yield, ear and kernel attributes can assist to understand the performance of maize plant under different environmental conditions and can be used in the variety development process to address farmer's preferences. These parameters are however still laborious and expensive to measure. A low-cost ear digital imaging method was developed that provides estimates of ear and kernel attributes i.e., ear number and size, kernel number and size as well as kernel weight from photos of ears harvested from field trial plots. The image processing method uses a script that runs in a batch mode on ImageJ; an open source software. Kernel weight was estimated using the total kernel number derived from the number of kernels visible on the image and the average kernel size. Data showed a good agreement in terms of accuracy and precision between ground truth measurements and data generated through image processing. Broad-sense heritability of the estimated parameters was in the range or higher than that for measured grain weight. Limitation of the method for kernel weight estimation is discussed. The method developed in this work provides an opportunity to significantly reduce the cost of selection in the breeding process, especially for resource constrained crop improvement programs and can be used to learn more about the genetic bases of grain yield determinants.
Manavella, Valeria; Romano, Federica; Garrone, Federica; Terzini, Mara; Bignardi, Cristina; Aimetti, Mario
2017-06-01
The aim of this study was to present and validate a novel procedure for the quantitative volumetric assessment of extraction sockets that combines cone-beam computed tomography (CBCT) and image processing techniques. The CBCT dataset of 9 severely resorbed extraction sockets was analyzed by means of two image processing software, Image J and Mimics, using manual and automated segmentation techniques. They were also applied on 5-mm spherical aluminum markers of known volume and on a polyvinyl chloride model of one alveolar socket scanned with Micro-CT to test the accuracy. Statistical differences in alveolar socket volume were found between the different methods of volumetric analysis (P<0.0001). The automated segmentation using Mimics was the most reliable and accurate method with a relative error of 1.5%, considerably smaller than the error of 7% and of 10% introduced by the manual method using Mimics and by the automated method using ImageJ. The currently proposed automated segmentation protocol for the three-dimensional rendering of alveolar sockets showed more accurate results, excellent inter-observer similarity and increased user friendliness. The clinical application of this method enables a three-dimensional evaluation of extraction socket healing after the reconstructive procedures and during the follow-up visits.
Computer-aided meiotic maturation assay (CAMMA) of zebrafish (danio rerio) oocytes in vitro.
Lessman, Charles A; Nathani, Ravikanth; Uddin, Rafique; Walker, Jamie; Liu, Jianxiong
2007-01-01
We have developed a new technique called Computer-Aided Meiotic Maturation Assay (CAMMA) for imaging large arrays of zebrafish oocytes and automatically collecting image files at regular intervals during meiotic maturation. This novel method uses a transparency scanner interfaced to a computer with macro programming that automatically scans and archives the image files. Images are stacked and analyzed with ImageJ to quantify changes in optical density characteristic of zebrafish oocyte maturation. Major advantages of CAMMA include (1) ability to image very large arrays of oocytes and follow individual cells over time, (2) simultaneously image many treatment groups, (3) digitized images may be stacked, animated, and analyzed in programs such as ImageJ, NIH-Image, or ScionImage, and (4) CAMMA system is inexpensive, costing less than most microscopes used in traditional assays. We have used CAMMA to determine the dose response and time course of oocyte maturation induced by 17alpha-hydroxyprogesterone (HP). Maximal decrease in optical density occurs around 5 hr after 0.1 micro g/ml HP (28.5 degrees C), approximately 3 hr after germinal vesicle migration (GVM) and dissolution (GVD). In addition to changes in optical density, GVD is accompanied by streaming of ooplasm to the animal pole to form a blastodisc. These dynamic changes are readily visualized by animating image stacks from CAMMA; thus, CAMMA provides a valuable source of time-lapse movies for those studying zebrafish oocyte maturation. The oocyte clearing documented by CAMMA is correlated to changes in size distribution of major yolk proteins upon SDS-PAGE, and, this in turn, is related to increased cyclin B(1) protein.
Jaccard, Nicolas; Griffin, Lewis D; Keser, Ana; Macown, Rhys J; Super, Alexandre; Veraitch, Farlan S; Szita, Nicolas
2014-03-01
The quantitative determination of key adherent cell culture characteristics such as confluency, morphology, and cell density is necessary for the evaluation of experimental outcomes and to provide a suitable basis for the establishment of robust cell culture protocols. Automated processing of images acquired using phase contrast microscopy (PCM), an imaging modality widely used for the visual inspection of adherent cell cultures, could enable the non-invasive determination of these characteristics. We present an image-processing approach that accurately detects cellular objects in PCM images through a combination of local contrast thresholding and post hoc correction of halo artifacts. The method was thoroughly validated using a variety of cell lines, microscope models and imaging conditions, demonstrating consistently high segmentation performance in all cases and very short processing times (<1 s per 1,208 × 960 pixels image). Based on the high segmentation performance, it was possible to precisely determine culture confluency, cell density, and the morphology of cellular objects, demonstrating the wide applicability of our algorithm for typical microscopy image processing pipelines. Furthermore, PCM image segmentation was used to facilitate the interpretation and analysis of fluorescence microscopy data, enabling the determination of temporal and spatial expression patterns of a fluorescent reporter. We created a software toolbox (PHANTAST) that bundles all the algorithms and provides an easy to use graphical user interface. Source-code for MATLAB and ImageJ is freely available under a permissive open-source license. © 2013 The Authors. Biotechnology and Bioengineering Published by Wiley Periodicals, Inc.
Jaccard, Nicolas; Griffin, Lewis D; Keser, Ana; Macown, Rhys J; Super, Alexandre; Veraitch, Farlan S; Szita, Nicolas
2014-01-01
The quantitative determination of key adherent cell culture characteristics such as confluency, morphology, and cell density is necessary for the evaluation of experimental outcomes and to provide a suitable basis for the establishment of robust cell culture protocols. Automated processing of images acquired using phase contrast microscopy (PCM), an imaging modality widely used for the visual inspection of adherent cell cultures, could enable the non-invasive determination of these characteristics. We present an image-processing approach that accurately detects cellular objects in PCM images through a combination of local contrast thresholding and post hoc correction of halo artifacts. The method was thoroughly validated using a variety of cell lines, microscope models and imaging conditions, demonstrating consistently high segmentation performance in all cases and very short processing times (<1 s per 1,208 × 960 pixels image). Based on the high segmentation performance, it was possible to precisely determine culture confluency, cell density, and the morphology of cellular objects, demonstrating the wide applicability of our algorithm for typical microscopy image processing pipelines. Furthermore, PCM image segmentation was used to facilitate the interpretation and analysis of fluorescence microscopy data, enabling the determination of temporal and spatial expression patterns of a fluorescent reporter. We created a software toolbox (PHANTAST) that bundles all the algorithms and provides an easy to use graphical user interface. Source-code for MATLAB and ImageJ is freely available under a permissive open-source license. Biotechnol. Bioeng. 2014;111: 504–517. © 2013 Wiley Periodicals, Inc. PMID:24037521
SarcOptiM for ImageJ: high-frequency online sarcomere length computing on stimulated cardiomyocytes.
Pasqualin, Côme; Gannier, François; Yu, Angèle; Malécot, Claire O; Bredeloux, Pierre; Maupoil, Véronique
2016-08-01
Accurate measurement of cardiomyocyte contraction is a critical issue for scientists working on cardiac physiology and physiopathology of diseases implying contraction impairment. Cardiomyocytes contraction can be quantified by measuring sarcomere length, but few tools are available for this, and none is freely distributed. We developed a plug-in (SarcOptiM) for the ImageJ/Fiji image analysis platform developed by the National Institutes of Health. SarcOptiM computes sarcomere length via fast Fourier transform analysis of video frames captured or displayed in ImageJ and thus is not tied to a dedicated video camera. It can work in real time or offline, the latter overcoming rotating motion or displacement-related artifacts. SarcOptiM includes a simulator and video generator of cardiomyocyte contraction. Acquisition parameters, such as pixel size and camera frame rate, were tested with both experimental recordings of rat ventricular cardiomyocytes and synthetic videos. It is freely distributed, and its source code is available. It works under Windows, Mac, or Linux operating systems. The camera speed is the limiting factor, since the algorithm can compute online sarcomere shortening at frame rates >10 kHz. In conclusion, SarcOptiM is a free and validated user-friendly tool for studying cardiomyocyte contraction in all species, including human. Copyright © 2016 the American Physiological Society.
A methodology for the semi-automatic digital image analysis of fragmental impactites
NASA Astrophysics Data System (ADS)
Chanou, A.; Osinski, G. R.; Grieve, R. A. F.
2014-04-01
A semi-automated digital image analysis method is developed for the comparative textural study of impact melt-bearing breccias. This method uses the freeware software ImageJ developed by the National Institute of Health (NIH). Digital image analysis is performed on scans of hand samples (10-15 cm across), based on macroscopic interpretations of the rock components. All image processing and segmentation are done semi-automatically, with the least possible manual intervention. The areal fraction of components is estimated and modal abundances can be deduced, where the physical optical properties (e.g., contrast, color) of the samples allow it. Other parameters that can be measured include, for example, clast size, clast-preferred orientations, average box-counting dimension or fragment shape complexity, and nearest neighbor distances (NnD). This semi-automated method allows the analysis of a larger number of samples in a relatively short time. Textures, granulometry, and shape descriptors are of considerable importance in rock characterization. The methodology is used to determine the variations of the physical characteristics of some examples of fragmental impactites.
Kuusisto, N; Vallittu, P K; Lassila, L V J
2015-01-01
Objectives: The aim was to compare the intensity of artefacts in CBCT images caused by different percentages of radio-opacifying material in composite simulation models of implants. Titanium and zirconia models of implants were used as a reference for the evaluation of the intensity of artefacts. Methods: Seven different percentages of radio-opacifying BaAlSiO2 fillers were added to composite resin to fabricate seven step wedges and simulation models of implants. Titanium and zirconia simulation models of implants were also fabricated. Aluminium step wedge was used as a reference for the measurement of grey values in intraoral radiographs. Step wedges were exposed with a Planmeca Intra X-ray machine (Planmeca Oy, Helsinki, Finland). All composite, titanium and zirconia simulation models of implants were exposed with a SCANORA® 3D dental X-ray machine (Soredex, Tuusula, Finland). Images and grey values were analysed with ImageJ software (National Institutes of Health, Bethesda, MD). To demonstrate possible artefacts between all the simulation models of implants, the images were also visually compared with each other using ImageJ software. Results: Artefacts were clearly present in CBCT images caused by titanium and zirconia and when the composite material consisted at least 20% BaAlSiO2. The intensity of artefacts increased when the radio-opacity of the composite material increased. Conclusions: Materials containing less radio-opacity produce less pronounced artefacts. The cut-off point for artefacts is at 20% radio-opaque filling material in composite material. PMID:25283364
CT Scans of Cores Metadata, Barrow, Alaska 2015
Katie McKnight; Tim Kneafsey; Craig Ulrich
2015-03-11
Individual ice cores were collected from Barrow Environmental Observatory in Barrow, Alaska, throughout 2013 and 2014. Cores were drilled along different transects to sample polygonal features (i.e. the trough, center and rim of high, transitional and low center polygons). Most cores were drilled around 1 meter in depth and a few deep cores were drilled around 3 meters in depth. Three-dimensional images of the frozen cores were constructed using a medical X-ray computed tomography (CT) scanner. TIFF files can be uploaded to ImageJ (an open-source imaging software) to examine soil structure and densities within each core.
Lineage mapper: A versatile cell and particle tracker
NASA Astrophysics Data System (ADS)
Chalfoun, Joe; Majurski, Michael; Dima, Alden; Halter, Michael; Bhadriraju, Kiran; Brady, Mary
2016-11-01
The ability to accurately track cells and particles from images is critical to many biomedical problems. To address this, we developed Lineage Mapper, an open-source tracker for time-lapse images of biological cells, colonies, and particles. Lineage Mapper tracks objects independently of the segmentation method, detects mitosis in confluence, separates cell clumps mistakenly segmented as a single cell, provides accuracy and scalability even on terabyte-sized datasets, and creates division and/or fusion lineages. Lineage Mapper has been tested and validated on multiple biological and simulated problems. The software is available in ImageJ and Matlab at isg.nist.gov.
NASA Astrophysics Data System (ADS)
Lisitsa, Y. V.; Yatskou, M. M.; Apanasovich, V. V.; Apanasovich, T. V.
2015-09-01
We have developed an algorithm for segmentation of cancer cell nuclei in three-channel luminescent images of microbiological specimens. The algorithm is based on using a correlation between fluorescence signals in the detection channels for object segmentation, which permits complete automation of the data analysis procedure. We have carried out a comparative analysis of the proposed method and conventional algorithms implemented in the CellProfiler and ImageJ software packages. Our algorithm has an object localization uncertainty which is 2-3 times smaller than for the conventional algorithms, with comparable segmentation accuracy.
Free software for performing physical analysis of systems for digital radiography and mammography.
Donini, Bruno; Rivetti, Stefano; Lanconelli, Nico; Bertolini, Marco
2014-05-01
In this paper, the authors present a free software for assisting users in achieving the physical characterization of x-ray digital systems and image quality checks. The program was developed as a plugin of a well-known public-domain suite ImageJ. The software can assist users in calculating various physical parameters such as the response curve (also termed signal transfer property), modulation transfer function (MTF), noise power spectra (NPS), and detective quantum efficiency (DQE). It also includes the computation of some image quality checks: defective pixel analysis, uniformity, dark analysis, and lag. The software was made available in 2009 and has been used during the last couple of years by many users who gave us valuable feedback for improving its usability. It was tested for achieving the physical characterization of several clinical systems for digital radiography and mammography. Various published papers made use of the outcomes of the plugin. This software is potentially beneficial to a variety of users: physicists working in hospitals, staff working in radiological departments, such as medical physicists, physicians, engineers. The plugin, together with a brief user manual, are freely available and can be found online (www.medphys.it/downloads.htm). With our plugin users can estimate all three most important parameters used for physical characterization (MTF, NPS, and also DQE). The plugin can run on any operating system equipped with ImageJ suite. The authors validated the software by comparing MTF and NPS curves on a common set of images with those obtained with other dedicated programs, achieving a very good agreement.
Measuring the Pain Area: An Intra- and Inter-Rater Reliability Study Using Image Analysis Software.
Dos Reis, Felipe Jose Jandre; de Barros E Silva, Veronica; de Lucena, Raphaela Nunes; Mendes Cardoso, Bruno Alexandre; Nogueira, Leandro Calazans
2016-01-01
Pain drawings have frequently been used for clinical information and research. The aim of this study was to investigate intra- and inter-rater reliability of area measurements performed on pain drawings. Our secondary objective was to verify the reliability when using computers with different screen sizes, both with and without mouse hardware. Pain drawings were completed by patients with chronic neck pain or neck-shoulder-arm pain. Four independent examiners participated in the study. Examiners A and B used the same computer with a 16-inch screen and wired mouse hardware. Examiner C used a notebook with a 16-inch screen and no mouse hardware, and Examiner D used a computer with an 11.6-inch screen and a wireless mouse. Image measurements were obtained using GIMP and NIH ImageJ computer programs. The length of all the images was measured using GIMP software to a set scale in ImageJ. Thus, each marked area was encircled and the total surface area (cm(2) ) was calculated for each pain drawing measurement. A total of 117 areas were identified and 52 pain drawings were analyzed. The intrarater reliability between all examiners was high (ICC = 0.989). The inter-rater reliability was also high. No significant differences were observed when using different screen sizes or when using or not using the mouse hardware. This suggests that the precision of these measurements is acceptable for the use of this method as a measurement tool in clinical practice and research. © 2014 World Institute of Pain.
Kefauver, Shawn C; Vicente, Rubén; Vergara-Díaz, Omar; Fernandez-Gallego, Jose A; Kerfal, Samir; Lopez, Antonio; Melichar, James P E; Serret Molins, María D; Araus, José L
2017-01-01
With the commercialization and increasing availability of Unmanned Aerial Vehicles (UAVs) multiple rotor copters have expanded rapidly in plant phenotyping studies with their ability to provide clear, high resolution images. As such, the traditional bottleneck of plant phenotyping has shifted from data collection to data processing. Fortunately, the necessarily controlled and repetitive design of plant phenotyping allows for the development of semi-automatic computer processing tools that may sufficiently reduce the time spent in data extraction. Here we present a comparison of UAV and field based high throughput plant phenotyping (HTPP) using the free, open-source image analysis software FIJI (Fiji is just ImageJ) using RGB (conventional digital cameras), multispectral and thermal aerial imagery in combination with a matching suite of ground sensors in a study of two hybrids and one conventional barely variety with ten different nitrogen treatments, combining different fertilization levels and application schedules. A detailed correlation network for physiological traits and exploration of the data comparing between treatments and varieties provided insights into crop performance under different management scenarios. Multivariate regression models explained 77.8, 71.6, and 82.7% of the variance in yield from aerial, ground, and combined data sets, respectively.
Analyzing huge pathology images with open source software.
Deroulers, Christophe; Ameisen, David; Badoual, Mathilde; Gerin, Chloé; Granier, Alexandre; Lartaud, Marc
2013-06-06
Digital pathology images are increasingly used both for diagnosis and research, because slide scanners are nowadays broadly available and because the quantitative study of these images yields new insights in systems biology. However, such virtual slides build up a technical challenge since the images occupy often several gigabytes and cannot be fully opened in a computer's memory. Moreover, there is no standard format. Therefore, most common open source tools such as ImageJ fail at treating them, and the others require expensive hardware while still being prohibitively slow. We have developed several cross-platform open source software tools to overcome these limitations. The NDPITools provide a way to transform microscopy images initially in the loosely supported NDPI format into one or several standard TIFF files, and to create mosaics (division of huge images into small ones, with or without overlap) in various TIFF and JPEG formats. They can be driven through ImageJ plugins. The LargeTIFFTools achieve similar functionality for huge TIFF images which do not fit into RAM. We test the performance of these tools on several digital slides and compare them, when applicable, to standard software. A statistical study of the cells in a tissue sample from an oligodendroglioma was performed on an average laptop computer to demonstrate the efficiency of the tools. Our open source software enables dealing with huge images with standard software on average computers. They are cross-platform, independent of proprietary libraries and very modular, allowing them to be used in other open source projects. They have excellent performance in terms of execution speed and RAM requirements. They open promising perspectives both to the clinician who wants to study a single slide and to the research team or data centre who do image analysis of many slides on a computer cluster. The virtual slide(s) for this article can be found here:http://www.diagnosticpathology.diagnomx.eu/vs/5955513929846272.
Analyzing huge pathology images with open source software
2013-01-01
Background Digital pathology images are increasingly used both for diagnosis and research, because slide scanners are nowadays broadly available and because the quantitative study of these images yields new insights in systems biology. However, such virtual slides build up a technical challenge since the images occupy often several gigabytes and cannot be fully opened in a computer’s memory. Moreover, there is no standard format. Therefore, most common open source tools such as ImageJ fail at treating them, and the others require expensive hardware while still being prohibitively slow. Results We have developed several cross-platform open source software tools to overcome these limitations. The NDPITools provide a way to transform microscopy images initially in the loosely supported NDPI format into one or several standard TIFF files, and to create mosaics (division of huge images into small ones, with or without overlap) in various TIFF and JPEG formats. They can be driven through ImageJ plugins. The LargeTIFFTools achieve similar functionality for huge TIFF images which do not fit into RAM. We test the performance of these tools on several digital slides and compare them, when applicable, to standard software. A statistical study of the cells in a tissue sample from an oligodendroglioma was performed on an average laptop computer to demonstrate the efficiency of the tools. Conclusions Our open source software enables dealing with huge images with standard software on average computers. They are cross-platform, independent of proprietary libraries and very modular, allowing them to be used in other open source projects. They have excellent performance in terms of execution speed and RAM requirements. They open promising perspectives both to the clinician who wants to study a single slide and to the research team or data centre who do image analysis of many slides on a computer cluster. Virtual slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/5955513929846272 PMID:23829479
Baldasso, Rosane Pérez; Tinoco, Rachel Lima Ribeiro; Vieira, Cristina Saft Matos; Fernandes, Mário Marques; Oliveira, Rogério Nogueira
2016-10-01
The process of forensic facial analysis may be founded on several scientific techniques and imaging modalities, such as digital signal processing, photogrammetry and craniofacial anthropometry. However, one of the main limitations in this analysis is the comparison of images acquired with different angles of incidence. The present study aimed to explore a potential approach for the correction of the planar perspective projection (PPP) in geometric structures traced from the human face. A technique for the correction of the PPP was calibrated within photographs of two geometric structures obtained with angles of incidence distorted in 80°, 60° and 45°. The technique was performed using ImageJ ® 1.46r (National Institutes of Health, Bethesda, Maryland). The corrected images were compared with photographs of the same object obtained in 90° (reference). In a second step, the technique was validated in a digital human face created using MakeHuman ® 1.0.2 (Free Software Foundation, Massachusetts, EUA) and Blender ® 2.75 (Blender ® Foundation, Amsterdam, Nederland) software packages. The images registered with angular distortion presented a gradual decrease in height when compared to the reference. The digital technique for the correction of the PPP is a valuable tool for forensic applications using photographic imaging modalities, such as forensic facial analysis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Quality controls for gamma cameras and PET cameras: development of a free open-source ImageJ program
NASA Astrophysics Data System (ADS)
Carlier, Thomas; Ferrer, Ludovic; Berruchon, Jean B.; Cuissard, Regis; Martineau, Adeline; Loonis, Pierre; Couturier, Olivier
2005-04-01
Acquisition data and treatments for quality controls of gamma cameras and Positron Emission Tomography (PET) cameras are commonly performed with dedicated program packages, which are running only on manufactured computers and differ from each other, depending on camera company and program versions. The aim of this work was to develop a free open-source program (written in JAVA language) to analyze data for quality control of gamma cameras and PET cameras. The program is based on the free application software ImageJ and can be easily loaded on any computer operating system (OS) and thus on any type of computer in every nuclear medicine department. Based on standard parameters of quality control, this program includes 1) for gamma camera: a rotation center control (extracted from the American Association of Physics in Medicine, AAPM, norms) and two uniformity controls (extracted from the Institute of Physics and Engineering in Medicine, IPEM, and National Electronic Manufacturers Association, NEMA, norms). 2) For PET systems, three quality controls recently defined by the French Medical Physicist Society (SFPM), i.e. spatial resolution and uniformity in a reconstructed slice and scatter fraction, are included. The determination of spatial resolution (thanks to the Point Spread Function, PSF, acquisition) allows to compute the Modulation Transfer Function (MTF) in both modalities of cameras. All the control functions are included in a tool box which is a free ImageJ plugin and could be soon downloaded from Internet. Besides, this program offers the possibility to save on HTML format the uniformity quality control results and a warning can be set to automatically inform users in case of abnormal results. The architecture of the program allows users to easily add any other specific quality control program. Finally, this toolkit is an easy and robust tool to perform quality control on gamma cameras and PET cameras based on standard computation parameters, is free, run on any type of computer and will soon be downloadable from the net (http://rsb.info.nih.gov/ij/plugins or http://nucleartoolkit.free.fr).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ushizima, Daniela M.; Bianchi, Andrea G. C.; DeBianchi, Christina
We introduce a computational analysis workflow to access properties of solid objects using nondestructive imaging techniques that rely on X-ray imaging. The goal is to process and quantify structures from material science sample cross sections. The algorithms can differentiate the porous media (high density material) from the void (background, low density media) using a Boolean classifier, so that we can extract features, such as volume, surface area, granularity spectrum, porosity, among others. Our workflow, Quant-CT, leverages several algorithms from ImageJ, such as statistical region merging and 3D object counter. It also includes schemes for bilateral filtering that use a 3Dmore » kernel, for parallel processing of sub-stacks, and for handling over-segmentation using histogram similarities. The Quant-CT supports fast user interaction, providing the ability for the user to train the algorithm via subsamples to feed its core algorithms with automated parameterization. Quant-CT plugin is currently available for testing by personnel at the Advanced Light Source and Earth Sciences Divisions and Energy Frontier Research Center (EFRC), LBNL, as part of their research on porous materials. The goal is to understand the processes in fluid-rock systems for the geologic sequestration of CO2, and to develop technology for the safe storage of CO2 in deep subsurface rock formations. We describe our implementation, and demonstrate our plugin on porous material images. This paper targets end-users, with relevant information for developers to extend its current capabilities.« less
NASA Astrophysics Data System (ADS)
Suchwalko, Agnieszka; Buzalewicz, Igor; Podbielska, Halina
2012-01-01
In the presented paper the optical system with converging spherical wave illumination for classification of bacteria species, is proposed. It allows for compression of the observation space, observation of Fresnel patterns, diffraction pattern scaling and low level of optical aberrations, which are not possessed by other optical configurations. Obtained experimental results have shown that colonies of specific bacteria species generate unique diffraction signatures. Analysis of Fresnel diffraction patterns of bacteria colonies can be fast and reliable method for classification and recognition of bacteria species. To determine the unique features of bacteria colonies diffraction patterns the image processing analysis was proposed. Classification can be performed by analyzing the spatial structure of diffraction patterns, which can be characterized by set of concentric rings. The characteristics of such rings depends on the bacteria species. In the paper, the influence of basic features and ring partitioning number on the bacteria classification, is analyzed. It is demonstrated that Fresnel patterns can be used for classification of following species: Salmonella enteritidis, Staplyococcus aureus, Proteus mirabilis and Citrobacter freundii. Image processing is performed by free ImageJ software, for which a special macro with human interaction, was written. LDA classification, CV method, ANOVA and PCA visualizations preceded by image data extraction were conducted using the free software R.
NeuronMetrics: Software for Semi-Automated Processing of Cultured-Neuron Images
Narro, Martha L.; Yang, Fan; Kraft, Robert; Wenk, Carola; Efrat, Alon; Restifo, Linda L.
2007-01-01
Using primary cell culture to screen for changes in neuronal morphology requires specialized analysis software. We developed NeuronMetrics™ for semi-automated, quantitative analysis of two-dimensional (2D) images of fluorescently labeled cultured neurons. It skeletonizes the neuron image using two complementary image-processing techniques, capturing fine terminal neurites with high fidelity. An algorithm was devised to span wide gaps in the skeleton. NeuronMetrics uses a novel strategy based on geometric features called faces to extract a branch-number estimate from complex arbors with numerous neurite-to-neurite contacts, without creating a precise, contact-free representation of the neurite arbor. It estimates total neurite length, branch number, primary neurite number, territory (the area of the convex polygon bounding the skeleton and cell body), and Polarity Index (a measure of neuronal polarity). These parameters provide fundamental information about the size and shape of neurite arbors, which are critical factors for neuronal function. NeuronMetrics streamlines optional manual tasks such as removing noise, isolating the largest primary neurite, and correcting length for self-fasciculating neurites. Numeric data are output in a single text file, readily imported into other applications for further analysis. Written as modules for ImageJ, NeuronMetrics provides practical analysis tools that are easy to use and support batch processing. Depending on the need for manual intervention, processing time for a batch of ~60 2D images is 1.0–2.5 hours, from a folder of images to a table of numeric data. NeuronMetrics’ output accelerates the quantitative detection of mutations and chemical compounds that alter neurite morphology in vitro, and will contribute to the use of cultured neurons for drug discovery. PMID:17270152
NeuronMetrics: software for semi-automated processing of cultured neuron images.
Narro, Martha L; Yang, Fan; Kraft, Robert; Wenk, Carola; Efrat, Alon; Restifo, Linda L
2007-03-23
Using primary cell culture to screen for changes in neuronal morphology requires specialized analysis software. We developed NeuronMetrics for semi-automated, quantitative analysis of two-dimensional (2D) images of fluorescently labeled cultured neurons. It skeletonizes the neuron image using two complementary image-processing techniques, capturing fine terminal neurites with high fidelity. An algorithm was devised to span wide gaps in the skeleton. NeuronMetrics uses a novel strategy based on geometric features called faces to extract a branch number estimate from complex arbors with numerous neurite-to-neurite contacts, without creating a precise, contact-free representation of the neurite arbor. It estimates total neurite length, branch number, primary neurite number, territory (the area of the convex polygon bounding the skeleton and cell body), and Polarity Index (a measure of neuronal polarity). These parameters provide fundamental information about the size and shape of neurite arbors, which are critical factors for neuronal function. NeuronMetrics streamlines optional manual tasks such as removing noise, isolating the largest primary neurite, and correcting length for self-fasciculating neurites. Numeric data are output in a single text file, readily imported into other applications for further analysis. Written as modules for ImageJ, NeuronMetrics provides practical analysis tools that are easy to use and support batch processing. Depending on the need for manual intervention, processing time for a batch of approximately 60 2D images is 1.0-2.5 h, from a folder of images to a table of numeric data. NeuronMetrics' output accelerates the quantitative detection of mutations and chemical compounds that alter neurite morphology in vitro, and will contribute to the use of cultured neurons for drug discovery.
Scare, J A; Slusarewicz, P; Noel, M L; Wielgus, K M; Nielsen, M K
2017-11-30
Fecal egg counts are emphasized for guiding equine helminth parasite control regimens due to the rise of anthelmintic resistance. This, however, poses further challenges, since egg counting results are prone to issues such as operator dependency, method variability, equipment requirements, and time commitment. The use of image analysis software for performing fecal egg counts is promoted in recent studies to reduce the operator dependency associated with manual counts. In an attempt to remove operator dependency associated with current methods, we developed a diagnostic system that utilizes a smartphone and employs image analysis to generate automated egg counts. The aims of this study were (1) to determine precision of the first smartphone prototype, the modified McMaster and ImageJ; (2) to determine precision, accuracy, sensitivity, and specificity of the second smartphone prototype, the modified McMaster, and Mini-FLOTAC techniques. Repeated counts on fecal samples naturally infected with equine strongyle eggs were performed using each technique to evaluate precision. Triplicate counts on 36 egg count negative samples and 36 samples spiked with strongyle eggs at 5, 50, 500, and 1000 eggs per gram were performed using a second smartphone system prototype, Mini-FLOTAC, and McMaster to determine technique accuracy. Precision across the techniques was evaluated using the coefficient of variation. In regards to the first aim of the study, the McMaster technique performed with significantly less variance than the first smartphone prototype and ImageJ (p<0.0001). The smartphone and ImageJ performed with equal variance. In regards to the second aim of the study, the second smartphone system prototype had significantly better precision than the McMaster (p<0.0001) and Mini-FLOTAC (p<0.0001) methods, and the Mini-FLOTAC was significantly more precise than the McMaster (p=0.0228). Mean accuracies for the Mini-FLOTAC, McMaster, and smartphone system were 64.51%, 21.67%, and 32.53%, respectively. The Mini-FLOTAC was significantly more accurate than the McMaster (p<0.0001) and the smartphone system (p<0.0001), while the smartphone and McMaster counts did not have statistically different accuracies. Overall, the smartphone system compared favorably to manual methods with regards to precision, and reasonably with regards to accuracy. With further refinement, this system could become useful in veterinary practice. Copyright © 2017 Elsevier B.V. All rights reserved.
Using a Video Camera to Measure the Radius of the Earth
ERIC Educational Resources Information Center
Carroll, Joshua; Hughes, Stephen
2013-01-01
A simple but accurate method for measuring the Earth's radius using a video camera is described. A video camera was used to capture a shadow rising up the wall of a tall building at sunset. A free program called ImageJ was used to measure the time it took the shadow to rise a known distance up the building. The time, distance and length of…
Digital image analysis to quantify carbide networks in ultrahigh carbon steels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hecht, Matthew D.; Webler, Bryan A.; Picard, Yoosuf N., E-mail: ypicard@cmu.edu
A method has been developed and demonstrated to quantify the degree of carbide network connectivity in ultrahigh carbon steels through digital image processing and analysis of experimental micrographs. It was shown that the network connectivity and carbon content can be correlated to toughness for various ultrahigh carbon steel specimens. The image analysis approach first involved segmenting the carbide network and pearlite matrix into binary contrast representations via a grayscale intensity thresholding operation. Next, the carbide network pixels were skeletonized and parceled into braches and nodes, allowing the determination of a connectivity index for the carbide network. Intermediate image processing stepsmore » to remove noise and fill voids in the network are also detailed. The connectivity indexes of scanning electron micrographs were consistent in both secondary and backscattered electron imaging modes, as well as across two different (50 × and 100 ×) magnifications. Results from ultrahigh carbon steels reported here along with other results from the literature generally showed lower connectivity indexes correlated with higher Charpy impact energy (toughness). A deviation from this trend was observed at higher connectivity indexes, consistent with a percolation threshold for crack propagation across the carbide network. - Highlights: • A method for carbide network analysis in steels is proposed and demonstrated. • ImageJ method extracts a network connectivity index from micrographs. • Connectivity index consistent in different imaging conditions and magnifications. • Impact energy may plateau when a critical network connectivity is exceeded.« less
NASA Astrophysics Data System (ADS)
Syarif, A. N.; Bangun, K.
2017-08-01
Zygomatic fractures are among the most common fractures to the facial skeleton. However, because no standard and reliable method of evaluation is available to assess postoperative patients, we often rely on photographs and subjective assessments. A portable mirror stand device (MiRS), which is a new method for the standardization of photography, was developed in our institution. Used with image analysis software, this device provides a new method for evaluating outcomes after the open reduction and internal fixation of zygomatic fractures. The portable mirror stand device was set up in our outpatient clinic at the Cleft Craniofacial Center at Cipto Mangunkusumo Hospital. Photographs of 11 postoperative patients were taken using the device, and they were analyzed both manually and using image analysis software (ImageJ 1.46) for symmetry. The two methods were then compared to assess the correlation and agreement of the results. The measurements taken using the manual method and the software-assisted method did not differ significantly, which indicated the good agreement between the two methods. The results of the symmetry achieved atour center were similar to other centers in the Asian region (ΔZy = 3.4±1.5 mm, ΔBc = 2.6±1.6 mm, ΔCh = 2.3±2.4 mm) compared with (ΔZy = 3.2±1.7 mm, ΔBc = 2.6±1.6 mm, ΔCh = 2.3±2.5 mm). The treatment of zygomatic fracture a tour center achieved good results. The portable mirror stand device assisted the image analysis software (ImageJ 1.46), which could be beneficial in assessing symmetry in postoperative zygomatic fracture patients.
Development of a thresholding algorithm for calcium classification at multiple CT energies
NASA Astrophysics Data System (ADS)
Ng, LY.; Alssabbagh, M.; Tajuddin, A. A.; Shuaib, I. L.; Zainon, R.
2017-05-01
The objective of this study was to develop a thresholding method for calcium classification with different concentration using single-energy computed tomography. Five different concentrations of calcium chloride were filled in PMMA tubes and placed inside a water-filled PMMA phantom (diameter 10 cm). The phantom was scanned at 70, 80, 100, 120 and 140 kV using a SECT. CARE DOSE 4D was used and the slice thickness was set to 1 mm for all energies. ImageJ software inspired by the National Institute of Health (NIH) was used to measure the CT numbers for each calcium concentration from the CT images. The results were compared with a developed algorithm for verification. The percentage differences between the measured CT numbers obtained from the developed algorithm and the ImageJ show similar results. The multi-thresholding algorithm was found to be able to distinguish different concentrations of calcium chloride. However, it was unable to detect low concentrations of calcium chloride and iron (III) nitrate with CT numbers between 25 HU and 65 HU. The developed thresholding method used in this study may help to differentiate between calcium plaques and other types of plaques in blood vessels as it is proven to have a good ability to detect the high concentration of the calcium chloride. However, the algorithm needs to be improved to solve the limitations of detecting calcium chloride solution which has a similar CT number with iron (III) nitrate solution.
Kinori, Michael; Hostovsky, Avner; Skaat, Alon; Schwartsman, Jonathan; Melamed, Shlomo
2014-01-01
To assess the use of a computerized program for evaluating the amount of trabecular meshwork (TM) pigmentation in normal (control), primary open-angle glaucoma (POAG), and pseudoexfoliation glaucoma/pigmentary dispersion glaucoma (PXFG/PDG) patients. All included patients were from the Goldschleger Eye Institute glaucoma clinic. After signing an informed consent, each patient's anterior chamber angle was photographed using a single photo-slit under the same conditions. Only one eye per patient was photographed. The superior TM and the inferior TM were documented. Then, the degree of "blackness" (representing melanin pigment) was assessed using the ImageJ program. Of the 43 eyes photographed, 8 were excluded because of low-quality images. Of the remaining 35 patients, 14 were normal, 10 had POAG, and 11 had PXFG/PDG. The amount of pigment was the same in the control and the POAG patients whether the inferior TM (P=0.24), superior TM (P=0.58), or the sum inferior TM+superior TM (P=0.85) was measured. The pigment level was significantly higher in the PXFG/PDG group than in the control group (inferior TM, P<0.01; superior TM, P=0.047; sum, P<0.01). The difference between the inferior and the superior TM pigment levels was found to be statistically insignificant in all the groups (normal, P=0.86; POAG, P=0.10; PXFG/PDG, P=0.22). The use of ImageJ software might play a role in the quantification of pigment evaluation of the TM.
VESGEN Software for Mapping and Quantification of Vascular Regulators
NASA Technical Reports Server (NTRS)
Parsons-Wingerter, Patricia A.; Vickerman, Mary B.; Keith, Patricia A.
2012-01-01
VESsel GENeration (VESGEN) Analysis is an automated software that maps and quantifies effects of vascular regulators on vascular morphology by analyzing important vessel parameters. Quantification parameters include vessel diameter, length, branch points, density, and fractal dimension. For vascular trees, measurements are reported as dependent functions of vessel branching generation. VESGEN maps and quantifies vascular morphological events according to fractal-based vascular branching generation. It also relies on careful imaging of branching and networked vascular form. It was developed as a plug-in for ImageJ (National Institutes of Health, USA). VESGEN uses image-processing concepts of 8-neighbor pixel connectivity, skeleton, and distance map to analyze 2D, black-and-white (binary) images of vascular trees, networks, and tree-network composites. VESGEN maps typically 5 to 12 (or more) generations of vascular branching, starting from a single parent vessel. These generations are tracked and measured for critical vascular parameters that include vessel diameter, length, density and number, and tortuosity per branching generation. The effects of vascular therapeutics and regulators on vascular morphology and branching tested in human clinical or laboratory animal experimental studies are quantified by comparing vascular parameters with control groups. VESGEN provides a user interface to both guide and allow control over the users vascular analysis process. An option is provided to select a morphological tissue type of vascular trees, network or tree-network composites, which determines the general collections of algorithms, intermediate images, and output images and measurements that will be produced.
Non-Ionic Highly Permeable Polymer Shells for Encapsulation of Living Cells
2011-05-01
I would like to thank Irina Drachuk for her extensive assistance in data collection and analysis , and Drs. Veronika Kozlovskaya and Olga Shchepelina...considered complete when the intensity of the photobleached region stabilized. The quantitative analysis was performed using ImageJ software, and curve...E., Tannin -protein complexes as radical scavengers and radical sinks. J Agric Food Chem 2001, 49 (10), 4917-23. 53. Lopes, G. K.; Schulman, H. M
Wakasaki, Rumie; Eiwaz, Mahaba; McClellan, Nicholas; Matsushita, Katsuyuki; Golgotiu, Kirsti; Hutchens, Michael P
2018-06-14
A technical challenge in translational models of kidney injury is determination of the extent of cell death. Histologic sections are commonly analyzed by area morphometry or unbiased stereology, but stereology requires specialized equipment. Therefore, a challenge to rigorous quantification would be addressed by an unbiased stereology tool with reduced equipment dependence. We hypothesized that it would be feasible to build a novel software component which would facilitate unbiased stereologic quantification on scanned slides, and that unbiased stereology would demonstrate greater precision and decreased bias compared with 2D morphometry. We developed a macro for the widely used image analysis program, Image J, and performed cardiac arrest with cardiopulmonary resuscitation (CA/CPR, a model of acute cardiorenal syndrome) in mice. Fluorojade-B stained kidney sections were analyzed using three methods to quantify cell death: gold standard stereology using a controlled stage and commercially-available software, unbiased stereology using the novel ImageJ macro, and quantitative 2D morphometry also using the novel macro. There was strong agreement between both methods of unbiased stereology (bias -0.004±0.006 with 95% limits of agreement -0.015 to 0.007). 2D morphometry demonstrated poor agreement and significant bias compared to either method of unbiased stereology. Unbiased stereology is facilitated by a novel macro for ImageJ and results agree with those obtained using gold-standard methods. Automated 2D morphometry overestimated tubular epithelial cell death and correlated modestly with values obtained from unbiased stereology. These results support widespread use of unbiased stereology for analysis of histologic outcomes of injury models.
Characterization of Upper Eyelid Tarsus and Lid Wiper Dimensions.
Navascues-Cornago, Maria; Maldonado-Codina, Carole; Gupta, Ruchi; Morgan, Philip B
2016-09-01
To measure various dimensions of the upper tarsal plate and the area of upper lid wiper staining. The repeatability of the method of measurement was investigated. Thirty-five healthy non-contact lens wearers were enrolled. The following parameters were measured from digital images of the upper eyelid captured with a slitlamp camera: length, height, and total area of the tarsal plate and area of lid wiper staining (lissamine green). Measurements were performed in a randomized and masked fashion on two separate occasions by the same investigator using ImageJ (National Institutes of Health). Coefficients of repeatability (COR) were calculated. The dimensions (mean±SD) of the tarsal plate were 20.6±1.9 mm length, 7.9±0.8 mm height, and 103.3±18.8 mm total area. The area of lid wiper staining was 2.7±2.0 mm. No association was found between tarsal dimensions and lid wiper staining (all P>0.05). Image analysis COR values were 0.6 mm tarsal length, 0.1 mm tarsal height, 1.2 mm tarsal area, and 0.4 mm lid wiper staining. There was no significant difference between repeated measurements for any parameter (all P>0.05). Limits of agreement were narrow for all parameters, indicating good agreement between repeated measurements. This work has demonstrated that there is a wide range in the dimensions of the upper tarsal plate in an urban UK population. No association was found between the upper tarsal dimensions and lid wiper staining. ImageJ was shown to be a repeatable method to measure the dimensions of the upper tarsal plate and upper lid wiper staining.
Chemical Genetic Screens for TDP-43 Modifiers and ALS Drug Discovery
2012-10-01
Mayo Clinic, United States of America Received October 11, 2011; Accepted January 5, 2012; Published February 21, 2012 Copyright: 2012 Vaccaro et al...Editor: Weidong Le, Baylor College of Medicine, Jiao Tong University School of Medicine, United States of America Received March 9, 2012; Accepted July...Grasshopper 2 Camera (Point Grey Research) at 30 Hz. The movies were then analyzed using the manual tracking plugin of ImageJ 1.45r software (NIH) and the swim
An implementation of the NiftyRec medical imaging library for PIXE-tomography reconstruction
NASA Astrophysics Data System (ADS)
Michelet, C.; Barberet, P.; Desbarats, P.; Giovannelli, J.-F.; Schou, C.; Chebil, I.; Delville, M.-H.; Gordillo, N.; Beasley, D. G.; Devès, G.; Moretto, P.; Seznec, H.
2017-08-01
A new development of the TomoRebuild software package is presented, including ;thick sample; correction for non linear X-ray production (NLXP) and X-ray absorption (XA). As in the previous versions, C++ programming with standard libraries was used for easier portability. Data reduction requires different steps which may be run either from a command line instruction or via a user friendly interface, developed as a portable Java plugin in ImageJ. All experimental and reconstruction parameters can be easily modified, either directly in the ASCII parameter files or via the ImageJ interface. A detailed user guide in English is provided. Sinograms and final reconstructed images are generated in usual binary formats that can be read by most public domain graphic softwares. New MLEM and OSEM methods are proposed, using optimized methods from the NiftyRec medical imaging library. An overview of the different medical imaging methods that have been used for ion beam microtomography applications is presented. In TomoRebuild, PIXET data reduction is performed for each chemical element independently and separately from STIMT, except for two steps where the fusion of STIMT and PIXET data is required: the calculation of the correction matrix and the normalization of PIXET data to obtain mass fraction distributions. Correction matrices for NLXP and XA are calculated using procedures extracted from the DISRA code, taking into account a large X-ray detection solid angle. For this, the 3D STIMT mass density distribution is used, considering a homogeneous global composition. A first example of PIXET experiment using two detectors is presented. Reconstruction results are compared and found in good agreement between different codes: FBP, NiftyRec MLEM and OSEM of the TomoRebuild software package, the original DISRA, its accelerated version provided in JPIXET and the accelerated MLEM version of JPIXET, with or without correction.
WE-D-204-06: An Open Source ImageJ CatPhan Analysis Tool
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelson, G
2015-06-15
Purpose: The CatPhan is a popular QA device for assessing CT image quality. There are a number of software options which perform analysis of the CatPhan. However, there is often little ability for the user to adjust the analysis if it isn’t running properly, and these are all expensive options. An open source tool is an effective solution. Methods: To use the software, the user imports the CT as an image sequence in ImageJ. The user then scrolls to the slice with the lateral dots. The user then runs the plugin. If tolerance constraints are not already created, the usermore » is prompted to enter them or to use generic tolerances. Upon completion of the analysis, the plugin calls pdfLaTex to compile the pdf report. There is a csv version of the report as well. A log of the results from all CatPhan scans is kept as a csv file. The user can use this to baseline the machine. Results: The tool is capable of detecting the orientation of the phantom. If the CatPhan was scanned backwards, one can simply flip the stack of images horizontally and proceed with the analysis. The analysis includes Sensitometry (estimating the effective beam energy), HU values and linearity, Low Contrast Visibility (using LDPE & Polystyrene), Contrast Scale, Geometric Accuracy, Slice Thickness Accuracy, Spatial resolution (giving the MTF using the line pairs as well as the point spread function), CNR, Low Contrast Detectability (including the raw data), Uniformity (including the Cupping Effect). Conclusion: This is a robust tool that analyzes more components of the CatPhan than other software options (with the exception of ImageOwl). It produces an elegant pdf and keeps a log of analyses for long-term tracking of the system. Because it is open source, users are able to customize any component of it.« less
Caldas, Victor E A; Punter, Christiaan M; Ghodke, Harshad; Robinson, Andrew; van Oijen, Antoine M
2015-10-01
Recent technical advances have made it possible to visualize single molecules inside live cells. Microscopes with single-molecule sensitivity enable the imaging of low-abundance proteins, allowing for a quantitative characterization of molecular properties. Such data sets contain information on a wide spectrum of important molecular properties, with different aspects highlighted in different imaging strategies. The time-lapsed acquisition of images provides information on protein dynamics over long time scales, giving insight into expression dynamics and localization properties. Rapid burst imaging reveals properties of individual molecules in real-time, informing on their diffusion characteristics, binding dynamics and stoichiometries within complexes. This richness of information, however, adds significant complexity to analysis protocols. In general, large datasets of images must be collected and processed in order to produce statistically robust results and identify rare events. More importantly, as live-cell single-molecule measurements remain on the cutting edge of imaging, few protocols for analysis have been established and thus analysis strategies often need to be explored for each individual scenario. Existing analysis packages are geared towards either single-cell imaging data or in vitro single-molecule data and typically operate with highly specific algorithms developed for particular situations. Our tool, iSBatch, instead allows users to exploit the inherent flexibility of the popular open-source package ImageJ, providing a hierarchical framework in which existing plugins or custom macros may be executed over entire datasets or portions thereof. This strategy affords users freedom to explore new analysis protocols within large imaging datasets, while maintaining hierarchical relationships between experiments, samples, fields of view, cells, and individual molecules.
NASA Astrophysics Data System (ADS)
Willis, Kyle V.; Srogi, LeeAnn; Lutz, Tim; Monson, Frederick C.; Pollock, Meagen
2017-12-01
Textures and compositions are critical information for interpreting rock formation. Existing methods to integrate both types of information favor high-resolution images of mineral compositions over small areas or low-resolution images of larger areas for phase identification. The method in this paper produces images of individual phases in which textural and compositional details are resolved over three orders of magnitude, from tens of micrometers to tens of millimeters. To construct these images, called Phase Composition Maps (PCMs), we make use of the resolution in backscattered electron (BSE) images and calibrate the gray scale values with mineral analyses by energy-dispersive X-ray spectrometry (EDS). The resulting images show the area of a standard thin section (roughly 40 mm × 20 mm) with spatial resolution as good as 3.5 μm/pixel, or more than 81 000 pixels/mm2, comparable to the resolution of X-ray element maps produced by wavelength-dispersive spectrometry (WDS). Procedures to create PCMs for mafic igneous rocks with multivariate linear regression models for minerals with solid solution (olivine, plagioclase feldspar, and pyroxenes) are presented and are applicable to other rock types. PCMs are processed using threshold functions based on the regression models to image specific composition ranges of minerals. PCMs are constructed using widely-available instrumentation: a scanning-electron microscope (SEM) with BSE and EDS X-ray detectors and standard image processing software such as ImageJ and Adobe Photoshop. Three brief applications illustrate the use of PCMs as petrologic tools: to reveal mineral composition patterns at multiple scales; to generate crystal size distributions for intracrystalline compositional zones and compare growth over time; and to image spatial distributions of minerals at different stages of magma crystallization by integrating textures and compositions with thermodynamic modeling.
IQM: An Extensible and Portable Open Source Application for Image and Signal Analysis in Java
Kainz, Philipp; Mayrhofer-Reinhartshuber, Michael; Ahammer, Helmut
2015-01-01
Image and signal analysis applications are substantial in scientific research. Both open source and commercial packages provide a wide range of functions for image and signal analysis, which are sometimes supported very well by the communities in the corresponding fields. Commercial software packages have the major drawback of being expensive and having undisclosed source code, which hampers extending the functionality if there is no plugin interface or similar option available. However, both variants cannot cover all possible use cases and sometimes custom developments are unavoidable, requiring open source applications. In this paper we describe IQM, a completely free, portable and open source (GNU GPLv3) image and signal analysis application written in pure Java. IQM does not depend on any natively installed libraries and is therefore runnable out-of-the-box. Currently, a continuously growing repertoire of 50 image and 16 signal analysis algorithms is provided. The modular functional architecture based on the three-tier model is described along the most important functionality. Extensibility is achieved using operator plugins, and the development of more complex workflows is provided by a Groovy script interface to the JVM. We demonstrate IQM’s image and signal processing capabilities in a proof-of-principle analysis and provide example implementations to illustrate the plugin framework and the scripting interface. IQM integrates with the popular ImageJ image processing software and is aiming at complementing functionality rather than competing with existing open source software. Machine learning can be integrated into more complex algorithms via the WEKA software package as well, enabling the development of transparent and robust methods for image and signal analysis. PMID:25612319
IQM: an extensible and portable open source application for image and signal analysis in Java.
Kainz, Philipp; Mayrhofer-Reinhartshuber, Michael; Ahammer, Helmut
2015-01-01
Image and signal analysis applications are substantial in scientific research. Both open source and commercial packages provide a wide range of functions for image and signal analysis, which are sometimes supported very well by the communities in the corresponding fields. Commercial software packages have the major drawback of being expensive and having undisclosed source code, which hampers extending the functionality if there is no plugin interface or similar option available. However, both variants cannot cover all possible use cases and sometimes custom developments are unavoidable, requiring open source applications. In this paper we describe IQM, a completely free, portable and open source (GNU GPLv3) image and signal analysis application written in pure Java. IQM does not depend on any natively installed libraries and is therefore runnable out-of-the-box. Currently, a continuously growing repertoire of 50 image and 16 signal analysis algorithms is provided. The modular functional architecture based on the three-tier model is described along the most important functionality. Extensibility is achieved using operator plugins, and the development of more complex workflows is provided by a Groovy script interface to the JVM. We demonstrate IQM's image and signal processing capabilities in a proof-of-principle analysis and provide example implementations to illustrate the plugin framework and the scripting interface. IQM integrates with the popular ImageJ image processing software and is aiming at complementing functionality rather than competing with existing open source software. Machine learning can be integrated into more complex algorithms via the WEKA software package as well, enabling the development of transparent and robust methods for image and signal analysis.
The Open Microscopy Environment: open image informatics for the biological sciences
NASA Astrophysics Data System (ADS)
Blackburn, Colin; Allan, Chris; Besson, Sébastien; Burel, Jean-Marie; Carroll, Mark; Ferguson, Richard K.; Flynn, Helen; Gault, David; Gillen, Kenneth; Leigh, Roger; Leo, Simone; Li, Simon; Lindner, Dominik; Linkert, Melissa; Moore, Josh; Moore, William J.; Ramalingam, Balaji; Rozbicki, Emil; Rustici, Gabriella; Tarkowska, Aleksandra; Walczysko, Petr; Williams, Eleanor; Swedlow, Jason R.
2016-07-01
Despite significant advances in biological imaging and analysis, major informatics challenges remain unsolved: file formats are proprietary, storage and analysis facilities are lacking, as are standards for sharing image data and results. While the open FITS file format is ubiquitous in astronomy, astronomical imaging shares many challenges with biological imaging, including the need to share large image sets using secure, cross-platform APIs, and the need for scalable applications for processing and visualization. The Open Microscopy Environment (OME) is an open-source software framework developed to address these challenges. OME tools include: an open data model for multidimensional imaging (OME Data Model); an open file format (OME-TIFF) and library (Bio-Formats) enabling free access to images (5D+) written in more than 145 formats from many imaging domains, including FITS; and a data management server (OMERO). The Java-based OMERO client-server platform comprises an image metadata store, an image repository, visualization and analysis by remote access, allowing sharing and publishing of image data. OMERO provides a means to manage the data through a multi-platform API. OMERO's model-based architecture has enabled its extension into a range of imaging domains, including light and electron microscopy, high content screening, digital pathology and recently into applications using non-image data from clinical and genomic studies. This is made possible using the Bio-Formats library. The current release includes a single mechanism for accessing image data of all types, regardless of original file format, via Java, C/C++ and Python and a variety of applications and environments (e.g. ImageJ, Matlab and R).
NASA Astrophysics Data System (ADS)
Carneiro, Vanda S. M.; Mota, Cláudia C. B. O.; Souza, Alex F.; Cajazeira, Marlus R. R.; Gerbi, Marleny E. M. M.; Gomes, Anderson S. L.
2018-02-01
This study evaluated the polymerization shrinkage of two experimental flowable composite resins (CR) with different proportions of Urethane dimethacrylate (UDMA)/triethylene glycol dimethacrylate (TEGDMA) monomers in the organic matrix (50:50 and 60:40, respectively). A commercially available flowable CR, Tetric N-Flow (Ivoclair Vivadent, Liechtenstein, Germany), was employed as the control group. The resins were inserted in a cylindrical teflon mold (7 mm diameter, 0.6 mm height) and scanned with OCT before photoactivation, immediately after and 15 minutes after light-curing (Radii-Cal, SDI, Australia, 1,200 mW/cm2 ) exposure. A Callisto SD-OCT system (Thorlabs Inc, USA), operating at 930 nm central wavelength was employed for imaging acquisition. Cross-sectional OCT images were captured with 8 mm transverse scanning (2000x512 matrix), and processed by the ImageJ software, for comparison between the scanning times and between groups. Pearson correlation showed significant shrinkage for all groups in each time analyzed. Kruskal-Wallis test showed greater polymerization shrinkage for the 50:50 UDMA/TEGDMA group (p=0.001), followed by the control group (p=0.018). TEGDMA concentration was proportionally related to the polymerization shrinkage of the flowable composite resins.
Automatic DNA Diagnosis for 1D Gel Electrophoresis Images using Bio-image Processing Technique.
Intarapanich, Apichart; Kaewkamnerd, Saowaluck; Shaw, Philip J; Ukosakit, Kittipat; Tragoonrung, Somvong; Tongsima, Sissades
2015-01-01
DNA gel electrophoresis is a molecular biology technique for separating different sizes of DNA fragments. Applications of DNA gel electrophoresis include DNA fingerprinting (genetic diagnosis), size estimation of DNA, and DNA separation for Southern blotting. Accurate interpretation of DNA banding patterns from electrophoretic images can be laborious and error prone when a large number of bands are interrogated manually. Although many bio-imaging techniques have been proposed, none of them can fully automate the typing of DNA owing to the complexities of migration patterns typically obtained. We developed an image-processing tool that automatically calls genotypes from DNA gel electrophoresis images. The image processing workflow comprises three main steps: 1) lane segmentation, 2) extraction of DNA bands and 3) band genotyping classification. The tool was originally intended to facilitate large-scale genotyping analysis of sugarcane cultivars. We tested the proposed tool on 10 gel images (433 cultivars) obtained from polyacrylamide gel electrophoresis (PAGE) of PCR amplicons for detecting intron length polymorphisms (ILP) on one locus of the sugarcanes. These gel images demonstrated many challenges in automated lane/band segmentation in image processing including lane distortion, band deformity, high degree of noise in the background, and bands that are very close together (doublets). Using the proposed bio-imaging workflow, lanes and DNA bands contained within are properly segmented, even for adjacent bands with aberrant migration that cannot be separated by conventional techniques. The software, called GELect, automatically performs genotype calling on each lane by comparing with an all-banding reference, which was created by clustering the existing bands into the non-redundant set of reference bands. The automated genotype calling results were verified by independent manual typing by molecular biologists. This work presents an automated genotyping tool from DNA gel electrophoresis images, called GELect, which was written in Java and made available through the imageJ framework. With a novel automated image processing workflow, the tool can accurately segment lanes from a gel matrix, intelligently extract distorted and even doublet bands that are difficult to identify by existing image processing tools. Consequently, genotyping from DNA gel electrophoresis can be performed automatically allowing users to efficiently conduct large scale DNA fingerprinting via DNA gel electrophoresis. The software is freely available from http://www.biotec.or.th/gi/tools/gelect.
A Freeware Path to Neutron Computed Tomography
NASA Astrophysics Data System (ADS)
Schillinger, Burkhard; Craft, Aaron E.
Neutron computed tomography has become a routine method at many neutron sources due to the availability of digital detection systems, powerful computers and advanced software. The commercial packages Octopus by Inside Matters and VGStudio by Volume Graphics have been established as a quasi-standard for high-end computed tomography. However, these packages require a stiff investment and are available to the users only on-site at the imaging facility to do their data processing. There is a demand from users to have image processing software at home to do further data processing; in addition, neutron computed tomography is now being introduced even at smaller and older reactors. Operators need to show a first working tomography setup before they can obtain a budget to build an advanced tomography system. Several packages are available on the web for free; however, these have been developed for X-rays or synchrotron radiation and are not immediately useable for neutron computed tomography. Three reconstruction packages and three 3D-viewers have been identified and used even for Gigabyte datasets. This paper is not a scientific publication in the classic sense, but is intended as a review to provide searchable help to make the described packages usable for the tomography community. It presents the necessary additional preprocessing in ImageJ, some workarounds for bugs in the software, and undocumented or badly documented parameters that need to be adapted for neutron computed tomography. The result is a slightly complicated, but surprisingly high-quality path to neutron computed tomography images in 3D, but not a replacement for the even more powerful commercial software mentioned above.
Brown, Kerry M; Donohue, Duncan E; D'Alessandro, Giampaolo; Ascoli, Giorgio A
2005-01-01
Digital reconstruction of neuronal arborizations is an important step in the quantitative investigation of cellular neuroanatomy. In this process, neurites imaged by microscopy are semi-manually traced through the use of specialized computer software and represented as binary trees of branching cylinders (or truncated cones). Such form of the reconstruction files is efficient and parsimonious, and allows extensive morphometric analysis as well as the implementation of biophysical models of electrophysiology. Here, we describe Neuron_ Morpho, a plugin for the popular Java application ImageJ that mediates the digital reconstruction of neurons from image stacks. Both the executable and code of Neuron_ Morpho are freely distributed (www.maths. soton.ac.uk/staff/D'Alessandro/morpho or www.krasnow.gmu.edu/L-Neuron), and are compatible with all major computer platforms (including Windows, Mac, and Linux). We tested Neuron_Morpho by reconstructing two neurons from each of the two preparations representing different brain areas (hippocampus and cerebellum), neuritic type (pyramidal cell dendrites and olivar axonal projection terminals), and labeling method (rapid Golgi impregnation and anterograde dextran amine), and quantitatively comparing the resulting morphologies to those of the same cells reconstructed with the standard commercial system, Neurolucida. None of the numerous morphometric measures that were analyzed displayed any significant or systematic difference between the two reconstructing systems.
A novel method to characterize silica bodies in grasses.
Dabney, Clemon; Ostergaard, Jason; Watkins, Eric; Chen, Changbin
2016-01-01
The deposition of silicon into epidermal cells of grass species is thought to be an important mechanism that plants use as a defense against pests and environmental stresses. There are a number of techniques available to study the size, density and distribution pattern of silica bodies in grass leaves. However, none of those techniques can provide a high-throughput analysis, especially for a great number of samples. We developed a method utilizing the autofluorescence of silica bodies to investigate their size and distribution, along with the number of carbon inclusions within the silica bodies of perennial grass species Koeleria macrantha. Fluorescence images were analyzed by image software Adobe Photoshop CS5 or ImageJ that remarkably facilitated the quantification of silica bodies in the dry ash. We observed three types of silica bodies or silica body related mineral structures. Silica bodies were detected on both abaxial and adaxial epidermis of K. macrantha leaves, although their sizes, density, and distribution patterns were different. No auto-fluorescence was detected from carbon inclusions. The combination of fluorescence microscopy and image processing software displayed efficient utilization in the identification and quantification of silica bodies in K. macrantha leaf tissues, which should applicable to biological, ecological and geological studies of grasses including forage, turf grasses and cereal crops.
NASA Astrophysics Data System (ADS)
Story, Mary E.; Webler, Bryan A.
2018-05-01
In this work we examine some observations made using high-temperature confocal scanning laser microscopy (HT-CSLM) during selective oxidation experiments. A plain carbon steel and advanced high-strength steel (AHSS) were selectively oxidized at high temperature (850-900°C) in either low oxygen or water vapor atmospheres. Surface evolution, including thermal grooving along grain boundaries and oxide growth, was viewed in situ during heating. Experiments investigated the influence of the microstructure and oxidizing atmosphere on selective oxidation behavior. Sequences of CSLM still frames collected during the experiment were processed with ImageJ to obtain histograms that showed a general darkening trend indicative of oxidation over time with all samples. Additional ex situ scanning electron microscopy and energy dispersive spectroscopy analysis supported in situ observations. Distinct oxidation behavior was observed for each case. Segregation, grain orientation, and extent of internal oxidation were all found to strongly influence surface evolution.
Bioceramic bone graft substitute for treatment of unicameral bone cysts.
Fillingham, Y A; Cvetanovich, G L; Haughom, B D; Erickson, B J; Gitelis, S
2016-08-01
To review the outcome of 12 patients who underwent debridement and injection of bioceramic for unicameral bone cyst (UBC). The resorption rate of the bioceramic was estimated by both traditional and novel methods. Records of 10 males and 2 females aged 6 to 34 years who underwent debridement and injection of bioceramic for UBC and were followed up for a mean of 41 (range, 26-57) months were reviewed. Functional outcome was assessed using the selfcompleted Musculoskeletal Tumor Society (MSTS) questionnaire. Radiological outcome was assessed using both original and modified Neer Outcome Rating System. The resorption rate of the bioceramic was estimated using both traditional and novel (ImageJ) methods. The mean MSTS score was 29.7 (range, 28-30) indicating excellent functional outcome. Of the 12 patients, 9 achieved complete healing and 3 had a residual cyst of 1%, 11%, and 52%. The last was considered a local recurrence, and the patient underwent repeat percutaneous injection of the bioceramic 1.5 years later and remained disease-free 4 years later. The mean resorption rate was 29% faster when estimated using the traditional rather than the ImageJ method (0.47 vs. 0.33 cm3/day, p=0.02). In the patient with recurrence, the resorption rate was faster than the average (0.68 vs. 0.33 cm3/day). A single percutaneous injection of the bioceramic for UBC achieved good functional and radiological outcome while avoiding donor-site morbidity.
Validation of a free software for unsupervised assessment of abdominal fat in MRI.
Maddalo, Michele; Zorza, Ivan; Zubani, Stefano; Nocivelli, Giorgio; Calandra, Giulio; Soldini, Pierantonio; Mascaro, Lorella; Maroldi, Roberto
2017-05-01
To demonstrate the accuracy of an unsupervised (fully automated) software for fat segmentation in magnetic resonance imaging. The proposed software is a freeware solution developed in ImageJ that enables the quantification of metabolically different adipose tissues in large cohort studies. The lumbar part of the abdomen (19cm in craniocaudal direction, centered in L3) of eleven healthy volunteers (age range: 21-46years, BMI range: 21.7-31.6kg/m 2 ) was examined in a breath hold on expiration with a GE T1 Dixon sequence. Single-slice and volumetric data were considered for each subject. The results of the visceral and subcutaneous adipose tissue assessments obtained by the unsupervised software were compared to supervised segmentations of reference. The associated statistical analysis included Pearson correlations, Bland-Altman plots and volumetric differences (VD % ). Values calculated by the unsupervised software significantly correlated with corresponding supervised segmentations of reference for both subcutaneous adipose tissue - SAT (R=0.9996, p<0.001) and visceral adipose tissue - VAT (R=0.995, p<0.001). Bland-Altman plots showed the absence of systematic errors and a limited spread of the differences. In the single-slice analysis, VD % were (1.6±2.9)% for SAT and (4.9±6.9)% for VAT. In the volumetric analysis, VD % were (1.3±0.9)% for SAT and (2.9±2.7)% for VAT. The developed software is capable of segmenting the metabolically different adipose tissues with a high degree of accuracy. This free add-on software for ImageJ can easily have a widespread and enable large-scale population studies regarding the adipose tissue and its related diseases. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Choi, Catherine J; Lefebvre, Daniel R; Yoon, Michael K
2016-06-01
The aim of this article is to validate the accuracy of Facial Assessment by Computer Evaluation (FACE) program in eyelid measurements. Sixteen subjects between the ages of 27 and 65 were included with IRB approval. Clinical measurements of upper eyelid margin reflex distance (MRD1) and inter-palpebral fissure (IPF) were obtained. Photographs were then taken with a digital single lens reflex camera with built-in pop-up flash (dSLR-pop) and a dSLR with lens-mounted ring flash (dSLR-ring) with the cameras upright, rotated 90, 180, and 270 degrees. The images were analyzed using both the FACE and ImageJ software to measure MRD1 and IPF.Thirty-two eyes of sixteen subjects were included. Comparison of clinical measurement of MRD1 and IPF with FACE measurements of photos in upright position showed no statistically significant differences for dSLR-pop (MRD1: p = 0.0912, IPF: p = 0.334) and for dSLR-ring (MRD1: p = 0.105, IPF: p = 0.538). One-to-one comparison of MRD1 and IPF measurements in four positions obtained with FACE versus ImageJ for dSLR-pop showed moderate to substantial agreement for MRD1 (intraclass correlation coefficient = 0.534 upright, 0.731 in 90 degree rotation, 0.627 in 180 degree rotation, 0.477 in 270 degree rotation) and substantial to excellent agreement in IPF (ICC = 0.740, 0.859, 0.849, 0.805). In photos taken with dSLR-ring, there was excellent agreement of all MRD1 (ICC = 0.916, 0.932, 0.845, 0.812) and IPF (ICC = 0.937, 0.938, 0.917, 0.888) values. The FACE program is a valid method for measuring margin reflex distance and inter-palpebral fissure.
Digital photogrammetry for quantitative wear analysis of retrieved TKA components.
Grochowsky, J C; Alaways, L W; Siskey, R; Most, E; Kurtz, S M
2006-11-01
The use of new materials in knee arthroplasty demands a way in which to accurately quantify wear in retrieved components. Methods such as damage scoring, coordinate measurement, and in vivo wear analysis have been used in the past. The limitations in these methods illustrate a need for a different methodology that can accurately quantify wear, which is relatively easy to perform and uses a minimal amount of expensive equipment. Off-the-shelf digital photogrammetry represents a potentially quick and easy alternative to what is readily available. Eighty tibial inserts were visually examined for front and backside wear and digitally photographed in the presence of two calibrated reference fields. All images were segmented (via manual and automated algorithms) using Adobe Photoshop and National Institute of Health ImageJ. Finally, wear was determined using ImageJ and Rhinoceros software. The absolute accuracy of the method and repeatability/reproducibility by different observers were measured in order to determine the uncertainty of wear measurements. To determine if variation in wear measurements was due to implant design, 35 implants of the three most prevalent designs were subjected to retrieval analysis. The overall accuracy of area measurements was 97.8%. The error in automated segmentation was found to be significantly lower than that of manual segmentation. The photogrammetry method was found to be reasonably accurate and repeatable in measuring 2-D areas and applicable to determining wear. There was no significant variation in uncertainty detected among different implant designs. Photogrammetry has a broad range of applicability since it is size- and design-independent. A minimal amount of off-the-shelf equipment is needed for the procedure and no proprietary knowledge of the implant is needed. (c) 2006 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Antoine, Bénard; Luc-Serge, Doucet; Sabine, Palle; Dmitri A., Ionov
2010-05-01
Petrogenetic relations in igneous rocks are usually studied in natural samples using classical optical microscopy and subsequent geochemical data acquisition. Multiphotonic Laser Scanning Confocal Microscopy (MLSCM) can be a powerful tool to section geological materials optically with sub-micrometric resolution and then generate a three-dimensional (3D) reconstruction (ca. 106 μm3 stack). MLSCM is used here to investigate textural relations of Monosulfide Solid Solution (MSS) with silicate phases in fresh spinel harzburgite xenoliths from the andesitic Avacha volcano (Kamchatka, Russia). The xenoliths contain MSS disseminated in olivine and orthopyroxene (opx) neoblasts as well as MSS-rich quenched magmatic opx veins [1]. First, Reflection Mode (RM) was tested on vein sulfides in resin-impregnated thick (120 μm) polished rock sections. Then we used a combination of Differential Interference Contrast (DIC) with a transmitted light detector, two photons-excited fluorescence (2PEF) and Second Harmonic Generation (SHG). Sequential imaging feature of the Leica TCS-SP2 software was applied. The excitation laser used for 2PEF was a COHERENT MIRA 900 with a 76Hz repetition rate and 800nm wavelength. Image stacks were analysed using ImageJ software [2]. The aim of the tests was to try to discriminate sulfides in silicate matrix as a tool for a better assessment of equilibrium conditions between the two phases. Preliminary results show that Fe-Ni rich MSS from vein and host rock have a strong auto-fluorescence in the Near UV-VIS domain (392-715 nm) whereas silicate matrix is only revealed through DIC. SHG is obtained only from dense nanocentrosymmetrical structures such as embedded medium (organic matter like glue and resin). The three images were recorded sequentially enabling efficient discrimination between the different components of the rock slices. RM permits reconstruction of the complete 3D structure of the rock slice. High resolution (ca. 0.2 μm along X-Y axis vs. 0.4 along Z axis) 2PEF enables analysis of 3D textural relations of tiny individual MSS globules (˜10 μm) in their various habitus. Statistical microgeometric descriptions can be derived from volumetric image data. These results may permit refinement of models concerning (re-) crystallisation kinetics and miscibility conditions of sulphur species in various media likely to act in different mantle environments: silicate melt, fluid-rich silicate melt, silicate-rich fluid. Furthermore, this study provides 3D images with improved resolution of several components (silicate phases, sulfides, silicate glass) over the full thickness (>100 μm) of rock slices which cannot be done with classical methods. Besides 3D imaging of ‘hidden' phases in mantle rocks, it opens up new possibilities for other domains in geosciences like crystallography or petrophysics. [1] Bénard & Ionov (2010) GRA, this volume [2] Abramoff, M.D., Magelhaes, P.J. & Ram, S.J. (2004) Image processing with ImageJ. Biophoton. Int., 11, 36-42
NASA Astrophysics Data System (ADS)
Manousaki, D.; Panagiotopoulou, A.; Bizimi, V.; Haynes, M. S.; Love, S.; Kallergi, M.
2017-11-01
The purpose of this study was the generation of ground truth files (GTFs) of the breast ducts from 3D images of the Invenia™ Automated Breast Ultrasound System (ABUS) system (GE Healthcare, Little Chalfont, UK) and the application of these GTFs for the optimization of the imaging protocol and the evaluation of a computer aided detection (CADe) algorithm developed for automated duct detection. Six lactating, nursing volunteers were scanned with the ABUS before and right after breastfeeding their infants. An expert in breast ultrasound generated rough outlines of the milk-filled ducts in the transaxial slices of all image volumes and the final GTFs were created by using thresholding and smoothing tools in ImageJ. In addition, a CADe algorithm automatically segmented duct like areas and its results were compared to the expert’s GTFs by estimating true positive fraction (TPF) or % overlap. The CADe output differed significantly from the expert’s but both detected a smaller than expected volume of the ducts due to insufficient contrast (ducts were partially filled with milk), discontinuities, and artifacts. GTFs were used to modify the imaging protocol and improve the CADe method. In conclusion, electronic GTFs provide a valuable tool in the optimization of a tomographic imaging system, the imaging protocol, and the CADe algorithms. Their generation, however, is an extremely time consuming, strenuous process, particularly for multi-slice examinations, and alternatives based on phantoms or simulations are highly desirable.
Quantitative imaging assay for NF-κB nuclear translocation in primary human macrophages
Noursadeghi, Mahdad; Tsang, Jhen; Haustein, Thomas; Miller, Robert F.; Chain, Benjamin M.; Katz, David R.
2008-01-01
Quantitative measurement of NF-κB nuclear translocation is an important research tool in cellular immunology. Established methodologies have a number of limitations, such as poor sensitivity, high cost or dependence on cell lines. Novel imaging methods to measure nuclear translocation of transcriptionally active components of NF-κB are being used but are also partly limited by the need for specialist imaging equipment or image analysis software. Herein we present a method for quantitative detection of NF-κB rel A nuclear translocation, using immunofluorescence microscopy and the public domain image analysis software ImageJ that can be easily adopted for cellular immunology research without the need for specialist image analysis expertise and at low cost. The method presented here is validated by demonstrating the time course and dose response of NF-κB nuclear translocation in primary human macrophages stimulated with LPS, and by comparison with a commercial NF-κB activation reporter cell line. PMID:18036607
Second Harmonic Generation Imaging Analysis of Collagen Arrangement in Human Cornea.
Park, Choul Yong; Lee, Jimmy K; Chuck, Roy S
2015-08-01
To describe the horizontal arrangement of human corneal collagen bundles by using second harmonic generation (SHG) imaging. Human corneas were imaged with an inverted two photon excitation fluorescence microscope. The excitation laser (Ti:Sapphire) was tuned to 850 nm. Backscatter signals of SHG were collected through a 425/30-nm bandpass emission filter. Multiple, consecutive, and overlapping image stacks (z-stacks) were acquired to generate three dimensional data sets. ImageJ software was used to analyze the arrangement pattern (irregularity) of collagen bundles at each image plane. Collagen bundles in the corneal lamellae demonstrated a complex layout merging and splitting within a single lamellar plane. The patterns were significantly different in the superficial and limbal cornea when compared with deep and central regions. Collagen bundles were smaller in the superficial layer and larger in deep lamellae. By using SHG imaging, the horizontal arrangement of corneal collagen bundles was elucidated at different depths and focal regions of the human cornea.
Computer-aided diagnosis of early knee osteoarthritis based on MRI T2 mapping.
Wu, Yixiao; Yang, Ran; Jia, Sen; Li, Zhanjun; Zhou, Zhiyang; Lou, Ting
2014-01-01
This work was aimed at studying the method of computer-aided diagnosis of early knee OA (OA: osteoarthritis). Based on the technique of MRI (MRI: Magnetic Resonance Imaging) T2 Mapping, through computer image processing, feature extraction, calculation and analysis via constructing a classifier, an effective computer-aided diagnosis method for knee OA was created to assist doctors in their accurate, timely and convenient detection of potential risk of OA. In order to evaluate this method, a total of 1380 data from the MRI images of 46 samples of knee joints were collected. These data were then modeled through linear regression on an offline general platform by the use of the ImageJ software, and a map of the physical parameter T2 was reconstructed. After the image processing, the T2 values of ten regions in the WORMS (WORMS: Whole-organ Magnetic Resonance Imaging Score) areas of the articular cartilage were extracted to be used as the eigenvalues in data mining. Then,a RBF (RBF: Radical Basis Function) network classifier was built to classify and identify the collected data. The classifier exhibited a final identification accuracy of 75%, indicating a good result of assisting diagnosis. Since the knee OA classifier constituted by a weights-directly-determined RBF neural network didn't require any iteration, our results demonstrated that the optimal weights, appropriate center and variance could be yielded through simple procedures. Furthermore, the accuracy for both the training samples and the testing samples from the normal group could reach 100%. Finally, the classifier was superior both in time efficiency and classification performance to the frequently used classifiers based on iterative learning. Thus it was suitable to be used as an aid to computer-aided diagnosis of early knee OA.
Grewal, Dilraj S; Chou, Jonathan; Rollins, Stuart D; Fawzi, Amani A
2014-01-01
To analyze the topographic correlation between reticular pseudodrusen (RPD) visualized on infrared reflectance (IR) and choroidal vasculature using en-face volumetric spectral-domain optical coherence tomography (SD-OCT). A masked observer marked individual RPD on IR images using ImageJ (NIH, Bethesda, MD). Using the macular volume scan (Cirrus, Carl Zeiss Meditec Inc, Dublin, CA), the RPE slab function was used to generate a C-scan of the most superficial choroidal vasculature. An independent masked grader created a topographic binary map of the choroidal vasculature by thresholding the en-face image, which was overlaid onto the IR map of RPD. For each IR image, ImageJ was used to generate a random set of dots as "control lesions". 17 eyes of 11 patients (78±13.7 years) with RPD were analyzed. The average number of RPD lesions identified on IR images was 414±71.5, of which 49.6±4.3% were located overlying the choroidal vasculature, compared to 45.4±4.0% in controls (p = 0.014). 50.4±4.3% of lesions overlay the choroidal stroma, of which 76.5±3.1% were ≤3 pixels from the choroidal vessels. The percentage of RPD lesions located within ≤3 pixels from the choroidal vasculature was significantly greater than the percentage located ≥7 pixels away. (p<0.0001). Compared to controls (71.6±3.8%), RPD were more likely to be located ≤3 pixels away from choroidal vessels (p = 0.014). In contrast, control lesions were more likely to be ≥7 pixels away from choroidal vessels than RPD (9.1±1.9% vs. 4.8±1.2%, respectively, p = 0.002). Our analysis shows that RPD lesions follow the underlying choroidal vasculature. Approximately half the RPD directly overlay the choroidal vessels and the majority of the remaining lesions were ≤3 pixels (≤30 microns) from the vessel edge, supporting the hypothesis that RPD maybe related to pathologic changes at the choroidal level.
Desset, Sophie; Poulet, Axel; Tatout, Christophe
2018-01-01
Image analysis is a classical way to study nuclear organization. While nuclear organization used to be investigated by colorimetric or fluorescent labeling of DNA or specific nuclear compartments, new methods in microscopy imaging now enable qualitative and quantitative analyses of chromatin pattern, and nuclear size and shape. Several procedures have been developed to prepare samples in order to collect 3D images for the analysis of spatial chromatin organization, but only few preserve the positional information of the cell within its tissue context. Here, we describe a whole mount tissue preparation procedure coupled to DNA staining using the PicoGreen ® intercalating agent suitable for image analysis of the nucleus in living and fixed tissues. 3D Image analysis is then performed using NucleusJ, an open source ImageJ plugin, which allows for quantifying variations in nuclear morphology such as nuclear volume, sphericity, elongation, and flatness as well as in heterochromatin content and position in respect to the nuclear periphery.
Changes in Sunken Eyes Combined with Blepharoptosis after Levator Resection.
Mawatari, Yuki; Fukushima, Mikiko; Kawaji, Takahiro
2017-12-01
This study aims to report the changes in sunken eyes combined with blepharoptosis after levator resection. Analysis involved 60 eyes from 32 patients with sunken eyes combined with blepharoptosis. Advancement of the levator aponeurosis and the Müller's muscle complex (levator resection) was performed in these patients. Area of upper eyelid sulcus (AES) was defined as the area of the upper eyelid shadow. The digital images were converted to black and white using image-processing software (Adobe Photoshop), and the AES was calculated using ImageJ software. In addition, margin reflex distance, eyebrow height (EBH), and AES were measured before and 3 months after surgery to assess the changes in the eyelids. Preoperative AES was significantly correlated to age ( P < 0.0001; r = 0.8062). Sunken eyes were remarkably improved after levator resection in all patients. Mean margin reflex distance significantly increased, whereas mean EBH and mean AES significantly decreased at 3 months after surgery ( P < 0.0001). The AES change was significantly correlated to the EBH change ( P < 0.0001; r = 0.5184). The principal aim of levator resection is to improve upper eyelid height and visual fields; however, this technique can alter the location of the eyebrow and upper orbital fat. The effects fill the hollowness of the upper eyelid and can remarkably improve sunken eyes.
Maity, Maitreya; Dhane, Dhiraj; Mungle, Tushar; Maiti, A K; Chakraborty, Chandan
2017-10-26
Web-enabled e-healthcare system or computer assisted disease diagnosis has a potential to improve the quality and service of conventional healthcare delivery approach. The article describes the design and development of a web-based distributed healthcare management system for medical information and quantitative evaluation of microscopic images using machine learning approach for malaria. In the proposed study, all the health-care centres are connected in a distributed computer network. Each peripheral centre manages its' own health-care service independently and communicates with the central server for remote assistance. The proposed methodology for automated evaluation of parasites includes pre-processing of blood smear microscopic images followed by erythrocytes segmentation. To differentiate between different parasites; a total of 138 quantitative features characterising colour, morphology, and texture are extracted from segmented erythrocytes. An integrated pattern classification framework is designed where four feature selection methods viz. Correlation-based Feature Selection (CFS), Chi-square, Information Gain, and RELIEF are employed with three different classifiers i.e. Naive Bayes', C4.5, and Instance-Based Learning (IB1) individually. Optimal features subset with the best classifier is selected for achieving maximum diagnostic precision. It is seen that the proposed method achieved with 99.2% sensitivity and 99.6% specificity by combining CFS and C4.5 in comparison with other methods. Moreover, the web-based tool is entirely designed using open standards like Java for a web application, ImageJ for image processing, and WEKA for data mining considering its feasibility in rural places with minimal health care facilities.
PRFM enhance wound healing process in skin graft.
Reksodiputro, Mirta; Widodo, Dini; Bashiruddin, Jenny; Siregar, Nurjati; Malik, Safarina
2014-12-01
Facial plastic and reconstructive surgery often used skin graft on defects that cannot be covered primarily by a local flap. However, wound healing using skin graft is slow, most of the time the graft is contractured and the take of graft is not optimal. Platelet rich fibrin matrix (PRFM) is a new generation of concentrated platelets that produce natural fibrin and reported to speed up the healing process. Application of PRFM in the skin graft implants is expected to increase the survival of the graft. We used porcine as animal models to elucidate the effect of autologous PRFM on wound healing in full-thickness (FTSG) and split-thickness (STSG) skin grafts. Survival level of the skin graft was determined by using ImageJ software based on the formation of collagen type 1 and graft take. We observed that the use of PRFM in FTSG and STSG increased type 1 collagen formation. We also found that PRFM addition in STSG gave the best skin graft take. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Belwalkar, A; Grasing, E; Van Geertruyden, W; Huang, Z; Misiolek, W Z
2008-07-01
Nanoporous anodic aluminum oxide (AAO) tubular membranes were fabricated from aluminum alloy tubes in sulfuric and oxalic acid electrolytes using a two-step anodization process. The membranes were investigated for characteristics such as pore size, interpore distance and thickness by varying applied voltage and electrolyte concentration. Morphology of the membranes was examined using light optical and scanning electron microscopy and characterized using ImageJ software. Results showed that membranes having narrow pore size and uniform pore distribution with parallel channel arrays were obtained. The pore sizes were ranging from 14 to 24 nm and the wall thicknesses as high as 76 microm. It was found that the pore size increased in direct proportion with the applied voltage and inversely with the electrolyte concentration while the interpore distance increased linearly with the applied voltage. It was also observed that increase in acid concentration increased tubular membrane wall thickness that improved mechanical handling. By using anodic alumina technology, robust ceramic tubes with uniformly distributed pore-structure and parallel nano-channels of lengths and sizes practical for industrial applications were reliably produced in quantity.
Belwalkar, A.; Grasing, E.; Huang, Z.; Misiolek, W.Z.
2008-01-01
Nanoporous anodic aluminum oxide (AAO) tubular membranes were fabricated from aluminum alloy tubes in sulfuric and oxalic acid electrolytes using a two-step anodization process. The membranes were investigated for characteristics such as pore size, interpore distance and thickness by varying applied voltage and electrolyte concentration. Morphology of the membranes was examined using light optical and scanning electron microscopy and characterized using ImageJ software. Results showed that membranes having narrow pore size and uniform pore distribution with parallel channel arrays were obtained. The pore sizes were ranging from 14 to 24 nm and the wall thicknesses as high as 76 µm. It was found that the pore size increased in direct proportion with the applied voltage and inversely with the electrolyte concentration while the interpore distance increased linearly with the applied voltage. It was also observed that increase in acid concentration increased tubular membrane wall thickness that improved mechanical handling. By using anodic alumina technology, robust ceramic tubes with uniformly distributed pore-structure and parallel nano-channels of lengths and sizes practical for industrial applications were reliably produced in quantity. PMID:19578471
Sexual differences in telomere selection in the wild.
Olsson, Mats; Pauliny, Angela; Wapstra, Erik; Uller, Tobias; Schwartz, Tonia; Miller, Emily; Blomqvist, Donald
2011-05-01
Telomere length is restored primarily through the action of the reverse transcriptase telomerase, which may contribute to a prolonged lifespan in some but not all species and may result in longer telomeres in one sex than the other. To what extent this is an effect of proximate mechanisms (e.g. higher stress in males, higher oestradiol/oestrogen levels in females), or is an evolved adaptation (stronger selection for telomere length in one sex), usually remains unknown. Sand lizard (Lacerta agilis) females have longer telomeres than males and better maintain telomere length through life than males do. We also show that telomere length more strongly contributes to life span and lifetime reproductive success in females than males and that telomere length is under sexually diversifying selection in the wild. Finally, we performed a selection analysis with number of recruited offspring into the adult population as a response variable with telomere length, life span and body size as predictor variables. This showed significant differences in selection pressures between the sexes with strong ongoing selection in females, with these three predictors explaining 63% of the variation in recruitment. Thus, the sexually dimorphic telomere dynamics with longer telomeres in females is a result of past and ongoing selection in sand lizards. Finally, we compared the results from our selection analyses based on Telometric-derived data to the results based on data generated by the software ImageJ. ImageJ resulted in shorter average telomere length, but this difference had virtually no qualitative effect on the patterns of ongoing selection. © 2011 Blackwell Publishing Ltd.
IPLaminator: an ImageJ plugin for automated binning and quantification of retinal lamination.
Li, Shuai; Woodfin, Michael; Long, Seth S; Fuerst, Peter G
2016-01-16
Information in the brain is often segregated into spatially organized layers that reflect the function of the embedded circuits. This is perhaps best exemplified in the layering, or lamination, of the retinal inner plexiform layer (IPL). The neurites of the retinal ganglion, amacrine and bipolar cell subtypes that form synapses in the IPL are precisely organized in highly refined strata within the IPL. Studies focused on developmental organization and cell morphology often use this layered stratification to characterize cells and identify the function of genes in development of the retina. A current limitation to such analysis is the lack of standardized tools to quantitatively analyze this complex structure. Most previous work on neuron stratification in the IPL is qualitative and descriptive. In this study we report the development of an intuitive platform to rapidly and reproducibly assay IPL lamination. The novel ImageJ based software plugin we developed: IPLaminator, rapidly analyzes neurite stratification patterns in the retina and other neural tissues. A range of user options allows researchers to bin IPL stratification based on fixed points, such as the neurites of cholinergic amacrine cells, or to define a number of bins into which the IPL will be divided. Options to analyze tissues such as cortex were also added. Statistical analysis of the output then allows a quantitative value to be assigned to differences in laminar patterning observed in different models, genotypes or across developmental time. IPLaminator is an easy to use software application that will greatly speed and standardize quantification of neuron organization.
Robotics and dynamic image analysis for studies of gene expression in plant tissues.
Hernandez-Garcia, Carlos M; Chiera, Joseph M; Finer, John J
2010-05-05
Gene expression in plant tissues is typically studied by destructive extraction of compounds from plant tissues for in vitro analyses. The methods presented here utilize the green fluorescent protein (gfp) gene for continual monitoring of gene expression in the same pieces of tissues, over time. The gfp gene was placed under regulatory control of different promoters and introduced into lima bean cotyledonary tissues via particle bombardment. Cotyledons were then placed on a robotic image collection system, which consisted of a fluorescence dissecting microscope with a digital camera and a 2-dimensional robotics platform custom-designed to allow secure attachment of culture dishes. Images were collected from cotyledonary tissues every hour for 100 hours to generate expression profiles for each promoter. Each collected series of 100 images was first subjected to manual image alignment using ImageReady to make certain that GFP-expressing foci were consistently retained within selected fields of analysis. Specific regions of the series measuring 300 x 400 pixels, were then selected for further analysis to provide GFP Intensity measurements using ImageJ software. Batch images were separated into the red, green and blue channels and GFP-expressing areas were identified using the threshold feature of ImageJ. After subtracting the background fluorescence (subtraction of gray values of non-expressing pixels from every pixel) in the respective red and green channels, GFP intensity was calculated by multiplying the mean grayscale value per pixel by the total number of GFP-expressing pixels in each channel, and then adding those values for both the red and green channels. GFP Intensity values were collected for all 100 time points to yield expression profiles. Variations in GFP expression profiles resulted from differences in factors such as promoter strength, presence of a silencing suppressor, or nature of the promoter. In addition to quantification of GFP intensity, the image series were also used to generate time-lapse animations using ImageReady. Time-lapse animations revealed that the clear majority of cells displayed a relatively rapid increase in GFP expression, followed by a slow decline. Some cells occasionally displayed a sudden loss of fluorescence, which may be associated with rapid cell death. Apparent transport of GFP across the membrane and cell wall to adjacent cells was also observed. Time lapse animations provided additional information that could not otherwise be obtained using GFP Intensity profiles or single time point image collections.
Fleischer, Luise; Sehner, Susanne; Gehl, Axel; Riemer, Martin; Raupach, Tobias; Anders, Sven
2017-05-01
Measurement of postmortem pupil width is a potential component of death time estimation. However, no standardized measurement method has been described. We analyzed a total of 71 digital images for pupil-iris ratio using the software ImageJ. Images were analyzed three times by four different examiners. In addition, serial images from 10 cases were taken between 2 and 50 h postmortem to detect spontaneous pupil changes. Intra- and inter-rater reliability of the method was excellent (ICC > 0.95). The method is observer independent and yields consistent results, and images can be digitally stored and re-evaluated. The method seems highly eligible for forensic and scientific purposes. While statistical analysis of spontaneous pupil changes revealed a significant polynomial of quartic degree for postmortem time (p = 0.001), an obvious pattern was not detected. These results do not indicate suitability of spontaneous pupil changes for forensic death time estimation, as formerly suggested. © 2016 American Academy of Forensic Sciences.
Romano, Pedro S.R.
2017-01-01
Background Previous quantitative studies on Bauruemys elegans (Suárez, 1969) shell variation, as well as the taphonomic interpretation of its type locality, have suggested that all specimens collected in this locality may have belonged to the same population. We rely on this hypothesis in a morphometric study of the skull. Also, we tentatively assessed the eating preference habits differentiation that might be explained as due to ontogenetic changes. Methods We carried out an ANOVA testing 29 linear measurements from 21 skulls of B. elegans taken by using a caliper and through images, using the ImageJ software. First, a Principal Components Analysis (PCA) was performed with 27 measurements (excluding total length and width characters; =raw data) in order to visualize the scatter plots based on the form variance only. Then, a second PCA was carried out using ratios of length and width of each original measurement to assess shape variation among individuals. Finally, original measurements were log-transformed to describe allometries over ontogeny. Results No statistical differences were found between caliper and ImageJ measurements. The first three PCs of the PCA with raw data comprised 70.2% of the variance. PC1 was related to size variation and all others related to shape variation. Two specimens plotted outside the 95% ellipse in PC1∼PC2 axes. The first three PCs of the PCA with ratios comprised 64% of the variance. When considering PC1∼PC2, all specimens plotted inside the 95% ellipse. In allometric analysis, five measurements were positively allometric, 19 were negatively allometric and three represented enantiometric allometry. Many bones of the posterior and the lateral emarginations lengthen due to increasing size, while jugal and the quadratojugal decrease in width. Discussion ImageJ is useful in replacing caliper since there was no statistical differences. Yet iterative imputation is more appropriate to deal with missing data in PCA. Some specimens show small differences in form and shape. Form differences were interpreted as occuring due to ontogeny, whereas shape differences are related to feeding changes during growth. Moreover, all outlier specimens are crushed and/or distorted, thus the form/shape differences may be partially due to taphonomy. The allometric lengthening of the parietal, quadrate, squamosal, maxilla, associated with the narrowing of jugal and quadratojugal may be related to changes in feeding habit between different stages of development. This change in shape might represent a progressive skull stretching and enlargement of posterior and lateral emargination during ontogeny, and consequently, the increment of the feeding-apparatus musculature. Smaller individuals may have fed on softer diet, whereas larger ones probably have had a harder diet, as seen in some living species of Podocnemis. We conclude that the skull variation might be related to differences in feeding habits over ontogeny in B. elegans. PMID:28413719
Stereoscopic radiographic images with thermal neutrons
NASA Astrophysics Data System (ADS)
Silvani, M. I.; Almeida, G. L.; Rogers, J. D.; Lopes, R. T.
2011-10-01
Spatial structure of an object can be perceived by the stereoscopic vision provided by eyes or by the parallax produced by movement of the object with regard to the observer. For an opaque object, a technique to render it transparent should be used, in order to make visible the spatial distribution of its inner structure, for any of the two approaches used. In this work, a beam of thermal neutrons at the main port of the Argonauta research reactor of the Instituto de Engenharia Nuclear in Rio de Janeiro/Brazil has been used as radiation to render the inspected objects partially transparent. A neutron sensitive Imaging Plate has been employed as a detector and after exposure it has been developed by a reader using a 0.5 μm laser beam, which defines the finest achievable spatial resolution of the acquired digital image. This image, a radiographic attenuation map of the object, does not represent any specific cross-section but a convoluted projection for each specific attitude of the object with regard to the detector. After taking two of these projections at different object attitudes, they are properly processed and the final image is viewed by a red and green eyeglass. For monochromatic images this processing involves transformation of black and white radiographies into red and white and green and white ones, which are afterwards merged to yield a single image. All the processes are carried out with the software ImageJ. Divergence of the neutron beam unfortunately spoils both spatial and contrast resolutions, which become poorer as object-detector distance increases. Therefore, in order to evaluate the range of spatial resolution corresponding to the 3D image being observed, a curve expressing spatial resolution against object-detector gap has been deduced from the Modulation Transfer Functions experimentally. Typical exposure times, under a reactor power of 170 W, were 6 min for both quantitative and qualitative measurements. In spite of its intrinsic constraints, this simple technique may provide valuable information about the object otherwise available only through more refined and expensive 3D tomography.
Ramos, Susie Medeiros Oliveira; Glavam, Adriana Pereira; Kubo, Tadeu Takao Almodovar; de Sá, Lidia Vasconcellos
2014-01-01
To develop a study aiming at optimizing myocardial perfusion imaging. Imaging of an anthropomorphic thorax phantom with a GE SPECT Ventri gamma camera, with varied activities and acquisition times, in order to evaluate the influence of these parameters on the quality of the reconstructed medical images. The (99m)Tc-sestamibi radiotracer was utilized, and then the images were clinically evaluated on the basis of data such as summed stress score, and on the technical image quality and perfusion. The software ImageJ was utilized in the data quantification. The results demonstrated that for the standard acquisition time utilized in the procedure (15 seconds per angle), the injected activity could be reduced by 33.34%. Additionally, even if the standard scan time is reduced by 53.34% (7 seconds per angle), the standard injected activity could still be reduced by 16.67%, without impairing the image quality and the diagnostic reliability. The described method and respective results provide a basis for the development of a clinical trial of patients in an optimized protocol.
Ramos, Susie Medeiros Oliveira; Glavam, Adriana Pereira; Kubo, Tadeu Takao Almodovar; de Sá, Lidia Vasconcellos
2014-01-01
Objective To develop a study aiming at optimizing myocardial perfusion imaging. Materials and Methods Imaging of an anthropomorphic thorax phantom with a GE SPECT Ventri gamma camera, with varied activities and acquisition times, in order to evaluate the influence of these parameters on the quality of the reconstructed medical images. The 99mTc-sestamibi radiotracer was utilized, and then the images were clinically evaluated on the basis of data such as summed stress score, and on the technical image quality and perfusion. The software ImageJ was utilized in the data quantification. Results The results demonstrated that for the standard acquisition time utilized in the procedure (15 seconds per angle), the injected activity could be reduced by 33.34%. Additionally, even if the standard scan time is reduced by 53.34% (7 seconds per angle), the standard injected activity could still be reduced by 16.67%, without impairing the image quality and the diagnostic reliability. Conclusion The described method and respective results provide a basis for the development of a clinical trial of patients in an optimized protocol. PMID:25741088
Use of sonic tomography to detect and quantify wood decay in living trees1
Gilbert, Gregory S.; Ballesteros, Javier O.; Barrios-Rodriguez, Cesar A.; Bonadies, Ernesto F.; Cedeño-Sánchez, Marjorie L.; Fossatti-Caballero, Nohely J.; Trejos-Rodríguez, Mariam M.; Pérez-Suñiga, José Moises; Holub-Young, Katharine S.; Henn, Laura A. W.; Thompson, Jennifer B.; García-López, Cesar G.; Romo, Amanda C.; Johnston, Daniel C.; Barrick, Pablo P.; Jordan, Fulvia A.; Hershcovich, Shiran; Russo, Natalie; Sánchez, Juan David; Fábrega, Juan Pablo; Lumpkin, Raleigh; McWilliams, Hunter A.; Chester, Kathleen N.; Burgos, Alana C.; Wong, E. Beatriz; Diab, Jonathan H.; Renteria, Sonia A.; Harrower, Jennifer T.; Hooton, Douglas A.; Glenn, Travis C.; Faircloth, Brant C.; Hubbell, Stephen P.
2016-01-01
Premise of the study: Field methodology and image analysis protocols using acoustic tomography were developed and evaluated as a tool to estimate the amount of internal decay and damage of living trees, with special attention to tropical rainforest trees with irregular trunk shapes. Methods and Results: Living trunks of a diversity of tree species in tropical rainforests in the Republic of Panama were scanned using an Argus Electronic PiCUS 3 Sonic Tomograph and evaluated for the amount and patterns of internal decay. A protocol using ImageJ analysis software was used to quantify the proportions of intact and compromised wood. The protocols provide replicable estimates of internal decay and cavities for trees of varying shapes, wood density, and bark thickness. Conclusions: Sonic tomography, coupled with image analysis, provides an efficient, noninvasive approach to evaluate decay patterns and structural integrity of even irregularly shaped living trees. PMID:28101433
Validation of a Custom-made Software for DQE Assessment in Mammography Digital Detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ayala-Dominguez, L.; Perez-Ponce, H.; Brandan, M. E.
2010-12-07
This works presents the validation of a custom-made software, designed and developed in Matlab, intended for routine evaluation of detective quantum efficiency DQE, according to algorithms described in the IEC 62220-1-2 standard. DQE, normalized noise power spectrum NNPS and pre-sampling modulation transfer function MTF were calculated from RAW images from a GE Senographe DS (FineView disabled) and a Siemens Novation system. Calculated MTF is in close agreement with results obtained with alternative codes: MTF lowbar tool (Maidment), ImageJ plug-in (Perez-Ponce) and MIQuaELa (Ayala). Overall agreement better than {approx_equal}90% was found in MTF; the largest differences were observed at frequencies closemore » to the Nyquist limit. For the measurement of NNPS and DQE, agreement is similar to that obtained in the MTF. These results suggest that the developed software can be used with confidence for image quality assessment.« less
CosmoQuest Transient Tracker: Opensource Photometry & Astrometry software
NASA Astrophysics Data System (ADS)
Myers, Joseph L.; Lehan, Cory; Gay, Pamela; Richardson, Matthew; CosmoQuest Team
2018-01-01
CosmoQuest is moving from online citizen science, to observational astronomy with the creation of Transient Trackers. This open source software is designed to identify asteroids and other transient/variable objects in image sets. Transient Tracker’s features in final form will include: astrometric and photometric solutions, identification of moving/transient objects, identification of variable objects, and lightcurve analysis. In this poster we present our initial, v0.1 release and seek community input.This software builds on the existing NIH funded ImageJ libraries. Creation of this suite of opensource image manipulation routines is lead by Wayne Rasband and is released primarily under the MIT license. In this release, we are building on these libraries to add source identification for point / point-like sources, and to do astrometry. Our materials released under the Apache 2.0 license on github (http://github.com/CosmoQuestTeam) and documentation can be found at http://cosmoquest.org/TransientTracker.
A rapid method for counting nucleated erythrocytes on stained blood smears by digital image analysis
Gering, E.; Atkinson, C.T.
2004-01-01
Measures of parasitemia by intraerythrocytic hematozoan parasites are normally expressed as the number of infected erythrocytes per n erythrocytes and are notoriously tedious and time consuming to measure. We describe a protocol for generating rapid counts of nucleated erythrocytes from digital micrographs of thin blood smears that can be used to estimate intensity of hematozoan infections in nonmammalian vertebrate hosts. This method takes advantage of the bold contrast and relatively uniform size and morphology of erythrocyte nuclei on Giemsa-stained blood smears and uses ImageJ, a java-based image analysis program developed at the U.S. National Institutes of Health and available on the internet, to recognize and count these nuclei. This technique makes feasible rapid and accurate counts of total erythrocytes in large numbers of microscope fields, which can be used in the calculation of peripheral parasitemias in low-intensity infections.
Gokhin, David S.; Fowler, Velia M.
2016-01-01
The periodically arranged thin filaments within the striated myofibrils of skeletal and cardiac muscle have precisely regulated lengths, which can change in response to developmental adaptations, pathophysiological states, and genetic perturbations. We have developed a user-friendly, open-source ImageJ plugin that provides a graphical user interface (GUI) for super-resolution measurement of thin filament lengths by applying Distributed Deconvolution (DDecon) analysis to periodic line scans collected from fluorescence images. In the workflow presented here, we demonstrate thin filament length measurement using a phalloidin-stained cryosection of mouse skeletal muscle. The DDecon plugin is also capable of measuring distances of any periodically localized fluorescent signal from the Z- or M-line, as well as distances between successive Z- or M-lines, providing a broadly applicable tool for quantitative analysis of muscle cytoarchitecture. These functionalities can also be used to analyze periodic fluorescence signals in nonmuscle cells. PMID:27644080
Pagès, Loïc
2014-01-01
Background and Aims Root branching, and in particular acropetal branching, is a common and important developmental process for increasing the number of growing tips and defining the distribution of their meristem size. This study presents a new method for characterizing the results of this process in natura from scanned images of young, branched parts of excavated roots. The method involves the direct measurement or calculation of seven different traits. Methods Young plants of 45 species of dicots were sampled from fields and gardens with uniform soils. Roots were separated, scanned and then measured using ImageJ software to determine seven traits related to root diameter and interbranch distance. Results The traits exhibited large interspecific variations, and covariations reflecting trade-offs. For example, at the interspecies level, the spacing of lateral roots (interbranch distance along the parent root) was strongly correlated to the diameter of the finest roots found in the species, and showed a continuum between two opposite strategies: making dense and fine lateral roots, or thick and well-spaced laterals. Conclusions A simple method is presented for classification of branching patterns in roots that allows relatively quick sampling and measurements to be undertaken. The feasibilty of the method is demonstrated for dicotyledonous species and it has the potential to be developed more broadly for other species and a wider range of enivironmental conditions. PMID:25062886
Uji, Akihito; Ooto, Sotaro; Hangai, Masanori; Arichika, Shigeta; Yoshimura, Nagahisa
2013-01-01
Purpose To investigate the effect of B-spline-based elastic image registration on adaptive optics scanning laser ophthalmoscopy (AO-SLO)-assisted capillary visualization. Methods AO-SLO videos were acquired from parafoveal areas in the eyes of healthy subjects and patients with various diseases. After nonlinear image registration, the image quality of capillary images constructed from AO-SLO videos using motion contrast enhancement was compared before and after B-spline-based elastic (nonlinear) image registration performed using ImageJ. For objective comparison of image quality, contrast-to-noise ratios (CNRS) for vessel images were calculated. For subjective comparison, experienced ophthalmologists ranked images on a 5-point scale. Results All AO-SLO videos were successfully stabilized by elastic image registration. CNR was significantly higher in capillary images stabilized by elastic image registration than in those stabilized without registration. The average ratio of CNR in images with elastic image registration to CNR in images without elastic image registration was 2.10 ± 1.73, with no significant difference in the ratio between patients and healthy subjects. Improvement of image quality was also supported by expert comparison. Conclusions Use of B-spline-based elastic image registration in AO-SLO-assisted capillary visualization was effective for enhancing image quality both objectively and subjectively. PMID:24265796
Shen, Qinhua; Kirschbaum, Miko U F; Hedley, Mike J; Camps Arbestain, Marta
2016-01-01
This study aimed to develop and test an unbiased and rapid methodology to estimate the length of external arbuscular mycorrhizal fungal (AMF) hyphae in soil. The traditional visual gridline intersection (VGI) method, which consists in a direct visual examination of the intersections of hyphae with gridlines on a microscope eyepiece after aqueous extraction, membrane-filtration, and staining (e.g., with trypan blue), was refined. For this, (i) images of the stained hyphae were taken by using a digital photomicrography technique to avoid the use of the microscope and the method was referred to as "digital gridline intersection" (DGI) method; and (ii), the images taken in (i) were processed and the hyphal length was measured by using ImageJ software, referred to as the "photomicrography-ImageJ processing" (PIP) method. The DGI and PIP methods were tested using known grade lengths of possum fur. Then they were applied to measure the hyphal lengths in soils with contrasting phosphorus (P) fertility status. Linear regressions were obtained between the known lengths (Lknown) of possum fur and the values determined by using either the DGI (LDGI) (LDGI = 0.37 + 0.97 × Lknown, r2 = 0.86) or PIP (LPIP) methods (LPIP = 0.33 + 1.01 × Lknown, r2 = 0.98). There were no significant (P > 0.05) differences between the LDGI and LPIP values. While both methods provided accurate estimation (slope of regression being 1.0), the PIP method was more precise, as reflected by a higher value of r2 and lower coefficients of variation. The average hyphal lengths (6.5-19.4 m g-1) obtained by the use of these methods were in the range of those typically reported in the literature (3-30 m g-1). Roots growing in P-deficient soil developed 2.5 times as many hyphae as roots growing in P-rich soil (17.4 vs 7.2 m g-1). These tests confirmed that the use of digital photomicrography in conjunction with either the grid-line intersection principle or image processing is a suitable method for the measurement of AMF hyphal lengths in soils for comparative investigations.
Downey, Mike J.; Jeziorska, Danuta M.; Ott, Sascha; Tamai, T. Katherine; Koentges, Georgy; Vance, Keith W.; Bretschneider, Till
2011-01-01
The extraction of fluorescence time course data is a major bottleneck in high-throughput live-cell microscopy. Here we present an extendible framework based on the open-source image analysis software ImageJ, which aims in particular at analyzing the expression of fluorescent reporters through cell divisions. The ability to track individual cell lineages is essential for the analysis of gene regulatory factors involved in the control of cell fate and identity decisions. In our approach, cell nuclei are identified using Hoechst, and a characteristic drop in Hoechst fluorescence helps to detect dividing cells. We first compare the efficiency and accuracy of different segmentation methods and then present a statistical scoring algorithm for cell tracking, which draws on the combination of various features, such as nuclear intensity, area or shape, and importantly, dynamic changes thereof. Principal component analysis is used to determine the most significant features, and a global parameter search is performed to determine the weighting of individual features. Our algorithm has been optimized to cope with large cell movements, and we were able to semi-automatically extract cell trajectories across three cell generations. Based on the MTrackJ plugin for ImageJ, we have developed tools to efficiently validate tracks and manually correct them by connecting broken trajectories and reassigning falsely connected cell positions. A gold standard consisting of two time-series with 15,000 validated positions will be released as a valuable resource for benchmarking. We demonstrate how our method can be applied to analyze fluorescence distributions generated from mouse stem cells transfected with reporter constructs containing transcriptional control elements of the Msx1 gene, a regulator of pluripotency, in mother and daughter cells. Furthermore, we show by tracking zebrafish PAC2 cells expressing FUCCI cell cycle markers, our framework can be easily adapted to different cell types and fluorescent markers. PMID:22194797
Dias, Roberto A; Gonçalves, Bruno P; da Rocha, Joana F; da Cruz E Silva, Odete A B; da Silva, Augusto M F; Vieira, Sandra I
2017-12-01
Neurons are specialized cells of the Central Nervous System whose function is intricately related to the neuritic network they develop to transmit information. Morphological evaluation of this network and other neuronal structures is required to establish relationships between neuronal morphology and function, and may allow monitoring physiological and pathophysiologic alterations. Fluorescence-based microphotographs are the most widely used in cellular bioimaging, but phase contrast (PhC) microphotographs are easier to obtain, more affordable, and do not require invasive, complicated and disruptive techniques. Despite the various freeware tools available for fluorescence-based images analysis, few exist that can tackle the more elusive and harder-to-analyze PhC images. To surpass this, an interactive semi-automated image processing workflow was developed to easily extract relevant information (e.g. total neuritic length, average cell body area) from both PhC and fluorescence neuronal images. This workflow, named 'NeuronRead', was developed in the form of an ImageJ macro. Its robustness and adaptability were tested and validated on rat cortical primary neurons under control and differentiation inhibitory conditions. Validation included a comparison to manual determinations and to a golden standard freeware tool for fluorescence image analysis. NeuronRead was subsequently applied to PhC images of neurons at distinct differentiation days and exposed or not to DAPT, a pharmacological inhibitor of the γ-secretase enzyme, which cleaves the well-known Alzheimer's amyloid precursor protein (APP) and the Notch receptor. Data obtained confirms a neuritogenic regulatory role for γ-secretase products and validates NeuronRead as a time- and cost-effective useful monitoring tool. Copyright © 2017. Published by Elsevier Inc.
Exsanguinated blood volume estimation using fractal analysis of digital images.
Sant, Sonia P; Fairgrieve, Scott I
2012-05-01
The estimation of bloodstain volume using fractal analysis of digital images of passive blood stains is presented. Binary digital photos of bloodstains of known volumes (ranging from 1 to 7 mL), dispersed in a defined area, were subjected to image analysis using FracLac V. 2.0 for ImageJ. The box-counting method was used to generate a fractal dimension for each trial. A positive correlation between the generated fractal number and the volume of blood was found (R(2) = 0.99). Regression equations were produced to estimate the volume of blood in blind trials. An error rate ranging from 78% for 1 mL to 7% for 6 mL demonstrated that as the volume increases so does the accuracy of the volume estimation. This method used in the preliminary study proved that bloodstain patterns may be deconstructed into mathematical parameters, thus removing the subjective element inherent in other methods of volume estimation. © 2012 American Academy of Forensic Sciences.
Strain Analysis of Stretched Tourmaline Crystals Using ImageJ, Microsoft Excel and PowerPoint
NASA Astrophysics Data System (ADS)
Bosbyshell, H.
2012-12-01
This poster describes an undergraduate structural geology lab exercise utilizing the Mohr's circle diagram for finite strain, constructed using measurements obtained from stretched tourmaline crystals. A small building housing HVAC equipment at the south end of West Chester University's Recitation Hall (itself made of serpentinite) is constructed of early-Cambrian Chickies Quartzite. Stretched tourmaline crystals, with segments joined by fibrous quartz, are visible on many surfaces (presumably originally bedding). While the original orientation of any stone is unknown, these rocks provide an opportunity for a short field exercise during a two-hour lab period and a great base for conducting strain analysis. It is always fun to ask how many in the class have ever noticed the tourmaline (few have). Students take photos using their cell phones or cameras. Since strain is a ratio the absolute size of the tourmaline crystals is immaterial. Nonetheless, this is a good opportunity to remind students of the importance of including a scale in their photographs. The photos are opened in ImageJ and the line tool is used to determine the original and final lengths of selected crystals. Students calculate strain parameters using Microsoft Excel. Then, we use Adobe Illustrator or the drafting capabilities of Microsoft PowerPoint 2010 to follow Ramsay and Huber's techniques using a Mohr's circle construction to determine the finite strain ellipse. If a stretching direction can be estimated, elongation of two crystals is all that is required to determine the strain ratio. If no stretching direction is apparent, three crystals are required for a more complicated analysis that allows for determination of the stretching direction, as well as the strain ratio.
Centeno, Christopher J; Pitts, John; Al-Sayegh, Hasan; Freeman, Michael D
2015-01-01
Introduction This was a prospective case series designed to investigate treatment for anterior cruciate ligament (ACL) tears using an injection of autologous bone marrow concentrate. Methods Consecutive adult patients presenting to a private outpatient interventional musculoskeletal and pain practice with knee pain, ACL laxity on exam, and magnetic resonance imaging (MRI) evidence of a grade 1, 2, or 3 ACL tears with less than 1 cm retraction were eligible for this study. Eligible patients were treated with an intraligamentous injection of autologous bone marrow concentrate, using fluoroscopic guidance. Pre- and postprocedural sagittal MRI images of the ACLs were analyzed using ImageJ software to objectively quantify changes between pre- and posttreatment scans. Five different types of measurement of ACL pixel intensity were examined as a proxy for ligament integrity. In addition pain visual analog scale (VAS) and Lower Extremity Functional Scale (LEFS) values were recorded at baseline and at 1 month, 3 months, 6 months, and annually postinjection. Objective outcomes measured were pre- to post-MRI measurement changes, as analyzed by the ImageJ software. Subjective outcomes measured were changes in the VAS and LEFS, and a self-rated percentage improvement. Results Seven of ten patients showed improvement in at least four of five objective measures of ACL integrity in their postprocedure MRIs. In the entire study group, the mean gray value, median, raw integrated density, and modal gray value all decreased toward low-signal ACLs (P=0.01, P=0.02, P=0.002, and P=0.08), indications of improved ligament integrity. Seven of ten patients responded to the self-rated metrics follow up. The mean VAS change was a decrease of 1.7 (P=0.25), the mean LEFS change was an increase of 23.3 (P=0.03), and mean reported improvement was 86.7%. Conclusion Based on this small case series, autologous bone marrow concentrate shows promise in the treatment of grade 1, 2, and possibly grade 3 ACL tears without retraction. Further investigation using a controlled study design is warranted. PMID:26261424
Eghrari, Allen O; Mumtaz, Aisha A; Garrett, Brian; Rezaei, Mahsa; Akhavan, Mina S; Riazuddin, S Amer; Gottsch, John D
2017-01-01
Retroillumination photography analysis is an objective tool for the assessment of the number and distribution of guttae in eyes affected with Fuchs corneal dystrophy (FCD). Current protocols include manual processing of images; here, we assess validity and interrater reliability of automated analysis across various levels of FCD severity. Retroillumination photographs of 97 FCD-affected corneas were acquired, and total counts of guttae were previously summated manually. For each cornea, a single image was loaded into ImageJ software. We reduced color variability and subtracted background noise. Reflection of light from each gutta was identified as a local area of maximum intensity and counted automatically. Noise tolerance level was titrated for each cornea by examining a small region of each image with automated overlay to ensure appropriate coverage of individual guttae. We tested interrater reliability of automated counts of guttae across a spectrum of clinical and educational experience. A set of 97 retroillumination photographs was analyzed. Clinical severity as measured by a modified Krachmer scale ranged from a severity level of 1 to 5 in the set of analyzed corneas. Automated counts by an ophthalmologist correlated strongly with Krachmer grading (R = 0.79) and manual counts (R = 0.88). Intraclass correlation coefficients demonstrated strong correlation at 0.924 (95% CI, 0.870-0.958) among cases analyzed by 3 students, and 0.869 (95% CI, 0.797-0.918) among cases for which images were analyzed by an ophthalmologist and 2 students. Automated retroillumination photography analysis allows for grading of FCD severity with high resolution across a spectrum of disease severity.
Eghrari, Allen O.; Mumtaz, Aisha A.; Garrett, Brian; Rezaei, Mahsa; Akhavan, Mina S.; Riazuddin, S. Amer; Gottsch, John D.
2016-01-01
Purpose Retroillumination photography analysis (RPA) is an objective tool for assessment of the number and distribution of guttae in eyes affected with Fuchs Corneal Dystrophy (FCD). Current protocols include manual processing of images; here we assess validity and interrater reliability of automated analysis across various levels of FCD severity. Methods Retroillumination photographs of 97 FCD-affected corneas were acquired and total counts of guttae previously summated manually. For each cornea, a single image was loaded into ImageJ software. We reduced color variability and subtracted background noise. Reflection of light from each gutta was identified as a local area of maximum intensity and counted automatically. Noise tolerance level was titrated for each cornea by examining a small region of each image with automated overlay to ensure appropriate coverage of individual guttae. We tested interrater reliability of automated counts of guttae across a spectrum of clinical and educational experience. Results A set of 97 retroillumination photographs were analyzed. Clinical severity as measured by a modified Krachmer scale ranged from a severity level of 1 to 5 in the set of analyzed corneas. Automated counts by an ophthalmologist correlated strongly with Krachmer grading (R2=0.79) and manual counts (R2=0.88). Intraclass correlation coefficient demonstrated strong correlation, at 0.924 (95% CI, 0.870- 0.958) among cases analyzed by three students, and 0.869 (95% CI, 0.797- 0.918) among cases for which images was analyzed by an ophthalmologist and two students. Conclusions Automated RPA allows for grading of FCD severity with high resolution across a spectrum of disease severity. PMID:27811565
Simple technique to measure toric intraocular lens alignment and stability using a smartphone.
Teichman, Joshua C; Baig, Kashif; Ahmed, Iqbal Ike K
2014-12-01
Toric intraocular lenses (IOLs) are commonly implanted to correct corneal astigmatism at the time of cataract surgery. Their use requires preoperative calculation of the axis of implantation and postoperative measurement to determine whether the IOL has been implanted with the proper orientation. Moreover, toric IOL alignment stability over time is important for the patient and for the longitudinal evaluation of toric IOLs. We present a simple, inexpensive, and precise method to measure the toric IOL axis using a camera-enabled cellular phone (iPhone 5S) and computer software (ImageJ). Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Single-faced GRAYQB™: a radiation mapping device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mayer, J.; Farfan, E.; Immel, D.
2013-12-12
GrayQb{trademark} is a novel technology that has the potential to characterize radioactively contaminated areas such as hot cells, gloveboxes, small and large rooms, hallways, and waste tanks. The goal of GrayQb{trademark} is to speed the process of decontaminating these areas, which reduces worker exposures and promotes ALARA considerations. The device employs Phosphorous Storage Plate (PSP) technology as its primary detector material. PSPs, commonly used for medical applications and non-destructive testing, can be read using a commercially available scanner. The goal of GrayQb{trademark} technology is to locate, quantify, and identify the sources of contamination. The purpose of the work documented inmore » this report was to better characterize the performance of GrayQb{trademark} in its ability to present overlay images of the PSP image and the associated visual image of the location being surveyed. The results presented in this report are overlay images identifying the location of hot spots in both controlled and field environments. The GrayQb{trademark} technology has been mainly tested in a controlled environment with known distances and source characteristics such as specific known radionuclides, dose rates, and strength. The original concept for the GrayQb{trademark} device involved utilizing the six faces of a cube configuration and was designed to be positioned in the center of a contaminated area for 3D mapping. A smaller single-faced GrayQb{trademark}, dubbed GrayQb SF, was designed for the purpose of conducting the characterization testing documented in this report. This lighter 2D version is ideal for applications where entry ports are too small for a deployment of the original GrayQb™ version or where only a single surface is of interest. The shape, size, and weight of these two designs have been carefully modeled to account for most limitations encountered in hot cells, gloveboxes, and contaminated areas. GrayQb{trademark} and GrayQb{trademark} SF share the same fundamental detection system design (e.g., pinhole and PSPs). Therefore, performance tests completed on the single face GrayQB in this report is also applicable to the six- faced GrayQB (e.g., ambient light sensitivity and PSP response). This report details the characterization of the GrayQb{trademark} SF in both an uncontrolled environment; specifically, the Savannah River Site (SRS) Plutonium Fuel Form Facility in Building 235-F (Metallurgical Building) and controlled testing at SRS’s Health Physics Instrument Calibration Facility and SRS’s R&D Engineering Imaging and Radiation Systems Building. In this report, the resulting images from the Calibration Facility were obtained by overlaying the PSP and visual images manually using ImageJ. The resulting images from the Building 235-F tests presented in this report were produced using ImageJ and applying response trends developed from controlled testing results. The GrayQb{trademark} technology has been developed in two main stages at Savannah River National Laboratory (SRNL): 1) the GrayQb{trademark} development was supported by SRNL’s Laboratory Directed Research and Development Program and 2) the GrayQb{trademark} SF development and its testing in Building 235-F were supported by the Office of Deactivation and Decommissioning and Facility Engineering (EM-13), U.S. Department of Energy – Office of Environmental Management.« less
Keene, Douglas R
2015-04-01
"Color blindness" is a variable trait, including individuals with just slight color vision deficiency to those rare individuals with a complete lack of color perception. Approximately 75% of those with color impairment are green diminished; most of those remaining are red diminished. Red-Green color impairment is sex linked with the vast majority being male. The deficiency results in reds and greens being perceived as shades of yellow; therefore red-green images presented to the public will not illustrate regions of distinction to these individuals. Tools are available to authors wishing to accommodate those with color vision deficiency; most notable are components in FIJI (an extension of ImageJ) and Adobe Photoshop. Using these tools, hues of magenta may be substituted for red in red-green images resulting in striking definition for both the color sighted and color impaired. Web-based tools may be used (importantly) by color challenged individuals to convert red-green images archived in web-accessible journal articles into two-color images, which they may then discern.
Poisson-event-based analysis of cell proliferation.
Summers, Huw D; Wills, John W; Brown, M Rowan; Rees, Paul
2015-05-01
A protocol for the assessment of cell proliferation dynamics is presented. This is based on the measurement of cell division events and their subsequent analysis using Poisson probability statistics. Detailed analysis of proliferation dynamics in heterogeneous populations requires single cell resolution within a time series analysis and so is technically demanding to implement. Here, we show that by focusing on the events during which cells undergo division rather than directly on the cells themselves a simplified image acquisition and analysis protocol can be followed, which maintains single cell resolution and reports on the key metrics of cell proliferation. The technique is demonstrated using a microscope with 1.3 μm spatial resolution to track mitotic events within A549 and BEAS-2B cell lines, over a period of up to 48 h. Automated image processing of the bright field images using standard algorithms within the ImageJ software toolkit yielded 87% accurate recording of the manually identified, temporal, and spatial positions of the mitotic event series. Analysis of the statistics of the interevent times (i.e., times between observed mitoses in a field of view) showed that cell division conformed to a nonhomogeneous Poisson process in which the rate of occurrence of mitotic events, λ exponentially increased over time and provided values of the mean inter mitotic time of 21.1 ± 1.2 hours for the A549 cells and 25.0 ± 1.1 h for the BEAS-2B cells. Comparison of the mitotic event series for the BEAS-2B cell line to that predicted by random Poisson statistics indicated that temporal synchronisation of the cell division process was occurring within 70% of the population and that this could be increased to 85% through serum starvation of the cell culture. © 2015 International Society for Advancement of Cytometry.
Cluet, David; Spichty, Martin; Delattre, Marie
2014-01-01
The mitotic spindle is a microtubule-based structure that elongates to accurately segregate chromosomes during anaphase. Its position within the cell also dictates the future cell cleavage plan, thereby determining daughter cell orientation within a tissue or cell fate adoption for polarized cells. Therefore, the mitotic spindle ensures at the same time proper cell division and developmental precision. Consequently, spindle dynamics is the matter of intensive research. Among the different cellular models that have been explored, the one-cell stage C. elegans embryo has been an essential and powerful system to dissect the molecular and biophysical basis of spindle elongation and positioning. Indeed, in this large and transparent cell, spindle poles (or centrosomes) can be easily detected from simple DIC microscopy by human eyes. To perform quantitative and high-throughput analysis of spindle motion, we developed a computer program ACT for Automated-Centrosome-Tracking from DIC movies of C. elegans embryos. We therefore offer an alternative to the image acquisition and processing of transgenic lines expressing fluorescent spindle markers. Consequently, experiments on large sets of cells can be performed with a simple setup using inexpensive microscopes. Moreover, analysis of any mutant or wild-type backgrounds is accessible because laborious rounds of crosses with transgenic lines become unnecessary. Last, our program allows spindle detection in other nematode species, offering the same quality of DIC images but for which techniques of transgenesis are not accessible. Thus, our program also opens the way towards a quantitative evolutionary approach of spindle dynamics. Overall, our computer program is a unique macro for the image- and movie-processing platform ImageJ. It is user-friendly and freely available under an open-source licence. ACT allows batch-wise analysis of large sets of mitosis events. Within 2 minutes, a single movie is processed and the accuracy of the automated tracking matches the precision of the human eye. PMID:24763198
Saghiri, Mohammad Ali; Nazari, Amir; Garcia-Godoy, Franklin; Asatourian, Armen; Malekzadeh, Mansour; Elyasi, Maryam
2013-12-01
This study evaluated the effects of nanoindentation on the surface of white mineral trioxide aggregate (WMTA), Bioaggregate and Nano WMTA cements. Cements were mixed according to the manufacturer directions, condensed inside glass tubes, and randomly divided into three groups (n = 8). Specimens were soaked in synthetic tissue fluid (pH = 7.4) and incubated for 3 days. Cement pellets were subjected to nanoindentation tests and observed by scanning electron microscopy. Then, the images were processed and the number of cracks and total surface area of defects on the surface were calculated and analyzed using ImageJ. Data were submitted to one-way analysis of variance and a post hoc Tukey's test. The lowest number of cracks and total surface of defects were detected in Nano WMTA samples; however, it was not significantly different from WMTA samples (p = 0.588), while the highest values were noticed in Bioaggregate specimens that were significantly different from Nano WMTA and WMTA (p = 0.0001). The surface of WMTA and Nano WMTA showed more resistance after exposure to nano-compressive forces which indicated a better surface tolerance against these forces and crack formation. This suggests these substances are more tolerant cement materials which can predictably withstand loaded situations in a clinical scenario.
Sodium Channel Expression and Localization at Demyelinated Sites in Painful Human Dental Pulp
Henry, Michael A.; Luo, Songjiang; Foley, Benjamin D.; Rzasa, Rachael S.; Johnson, Lonnie R.; Levinson, S. Rock
2009-01-01
The expression of sodium channels (NaCh(s)) change after inflammatory and nerve lesions and this change has been implicated in the generation of pain states. Here we examine NaCh expression within nerve fibers from normal and painful extracted human teeth with special emphasis on their localization within large accumulations, like those seen at nodes of Ranvier. Pulpal tissue sections from normal wisdom teeth and from teeth with large carious lesions associated with severe and spontaneous pain were double-stained with pan-specific NaCh antibody and caspr (paranodal protein used to visualize nodes of Ranvier) antibody, while additional sections were triple-stained with NaCh, caspr and myelin basic protein (MBP) antibodies. Z-series of images were obtained with the confocal microscope and evaluated with NIH ImageJ software to quantify the density and size of NaCh accumulations, and to characterize NaCh localization at caspr-identified typical and atypical nodal sites. Although the results showed variability in the overall density and size of NaCh accumulations in painful samples, a common finding included the remodeling of NaChs at atypical nodal sites. This remodeling of NaChs included prominent NaCh expression within nerve regions that showed a selective loss of MBP staining in a pattern consistent with a demyelinating process. PMID:19559391
Miere, Alexandra; Oubraham, Hassiba; Amoroso, Francesca; Butori, Pauline; Astroz, Polina; Semoun, Oudy; Bruyere, Elsa; Pedinielli, Alexandre; Addou-Regnard, Manar; Jung, Camille; Cohen, Salomon Y; Souied, Eric H
2018-01-01
To compare the qualitative and quantitative choroidal neovascularization (CNV) changes after antivascular endothelial growth factor (anti-VEGF) therapy in treatment-naïve and treated eyes with age-related macular degeneration (AMD) using optical coherence tomography angiography (OCTA). Consecutive patients with neovascular AMD underwent multimodal imaging, including OCTA (AngioPlex, CIRRUS HD-OCT model 5000; Carl Zeiss Meditec, Inc., Dublin, OH) at baseline and at three monthly follow-up visits. Treatment-naive AMD patients undergoing anti-VEGF loading phase were included in group A, while treated patients were included in group B. Qualitative and quantitative OCTA analyses were performed on outer retina to choriocapillaris (ORCC) slab. CNV size was measured using a free image analysis software (ImageJ, open-source imaging processing software, 2.0.0). Twenty-five eyes of 25 patients were enrolled in our study (mean age 78.32 ± 6.8 years): 13 treatment-naïve eyes in group A and 12 treated eyes in group B. While qualitative analysis revealed no significant differences from baseline to follow-up in the two groups, quantitative analysis showed in group A a significant decrease in lesion area ( P = 0.023); in group B, no significant change in the lesion area was observed during anti-VEGF therapy ( P = 0.93). Treatment-naïve and treated eyes with CNV secondary to neovascular AMD respond differently to anti-VEGF therapy. This should be taken into account when using OCTA for CNV follow-up or planning therapeutic strategies.
Changes in nuclear morphology and chromatin texture of basal keratinocytes in melasma.
Brianezi, G; Handel, A C; Schmitt, J V; Miot, L D B; Miot, H A
2015-04-01
The pathogenesis of melasma and the role of keratinocytes in disease development and maintenance are not completely understood. Dermal abnormalities, the expression of inflammatory mediators, growth factors, epithelial expression of melanocortin and sexual hormones receptors suggest that not only melanocytes, but entire epidermal melanin unit is involved in melasma physiopathology. To compare nuclear morphological features and chromatin texture between basal keratinocytes in facial melasma and adjacent normal skin. We took facial skin biopsies (2 mm melasma and adjacent normal skin) from women processed for haematoxylin and eosin. Thirty non-overlapping basal keratinocyte nuclei were segmented and descriptors of area, highest diameter, perimeter, circularity, pixel intensity, profilometric index (Ra) and fractal dimension were extracted using ImageJ software. Basal keratinocyte nuclei from facial melasma epidermis displayed larger size, irregular shape, hyperpigmentation and chromatin heterogeneity by fractal dimension than perilesional skin. Basal keratinocytes from facial melasma display changes in nuclear form and chromatin texture, suggesting that the phenotype differences between melasma and adjacent facial skin can result from complete epidermal melanin unit alterations, not just hypertrophic melanocytes. © 2014 European Academy of Dermatology and Venereology.
Age estimation using pulp/tooth area ratio in maxillary canines-A digital image analysis.
Juneja, Manjushree; Devi, Yashoda B K; Rakesh, N; Juneja, Saurabh
2014-09-01
Determination of age of a subject is one of the most important aspects of medico-legal cases and anthropological research. Radiographs can be used to indirectly measure the rate of secondary dentine deposition which is depicted by reduction in the pulp area. In this study, 200 patients of Karnataka aged between 18-72 years were selected for the study. Panoramic radiographs were made and indirectly digitized. Radiographic images of maxillary canines (RIC) were processed using a computer-aided drafting program (ImageJ). The variables pulp/root length (p), pulp/tooth length (r), pulp/root width at enamel-cementum junction (ECJ) level (a), pulp/root width at mid-root level (c), pulp/root width at midpoint level between ECJ level and mid-root level (b) and pulp/tooth area ratio (AR) were recorded. All the morphological variables including gender were statistically analyzed to derive regression equation for estimation of age. It was observed that 2 variables 'AR' and 'b' contributed significantly to the fit and were included in the regression model, yielding the formula: Age = 87.305-480.455(AR)+48.108(b). Statistical analysis indicated that the regression equation with selected variables explained 96% of total variance with the median of the residuals of 0.1614 years and standard error of estimate of 3.0186 years. There is significant correlation between age and morphological variables 'AR' and 'b' and the derived population specific regression equation can be potentially used for estimation of chronological age of individuals of Karnataka origin.
SpotCaliper: fast wavelet-based spot detection with accurate size estimation.
Püspöki, Zsuzsanna; Sage, Daniel; Ward, John Paul; Unser, Michael
2016-04-15
SpotCaliper is a novel wavelet-based image-analysis software providing a fast automatic detection scheme for circular patterns (spots), combined with the precise estimation of their size. It is implemented as an ImageJ plugin with a friendly user interface. The user is allowed to edit the results by modifying the measurements (in a semi-automated way), extract data for further analysis. The fine tuning of the detections includes the possibility of adjusting or removing the original detections, as well as adding further spots. The main advantage of the software is its ability to capture the size of spots in a fast and accurate way. http://bigwww.epfl.ch/algorithms/spotcaliper/ zsuzsanna.puspoki@epfl.ch Supplementary data are available at Bioinformatics online. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Chang, Y.; Zhou, D.; Wang, Y. L.; Huang, H. H.
2016-12-01
This study investigated the repulsive interaction of sulfide layers on compressor impeller blades remanufactured through plasma spray welding (PSW). Sulfide layers on the blades made of FV(520)B steel were prepared through multifarious corrosion experiments, and PSW was utilized to remanufacture blade specimens. The specimens were evaluated through optical microscopy, scanning electron microscopy, energy-dispersive spectroscopy, 3D surface topography, x-ray diffraction, ImageJ software analysis, Vicker's micro-hardness test and tensile tests. Results showed a large number of sulfide inclusions in the fusion zone generated by sulfide layers embodied into the molten pool during PSW. These sulfide inclusions seriously degraded the mechanical performance of the blades remanufactured through PSW.
Improved scatter correction with factor analysis for planar and SPECT imaging
NASA Astrophysics Data System (ADS)
Knoll, Peter; Rahmim, Arman; Gültekin, Selma; Šámal, Martin; Ljungberg, Michael; Mirzaei, Siroos; Segars, Paul; Szczupak, Boguslaw
2017-09-01
Quantitative nuclear medicine imaging is an increasingly important frontier. In order to achieve quantitative imaging, various interactions of photons with matter have to be modeled and compensated. Although correction for photon attenuation has been addressed by including x-ray CT scans (accurate), correction for Compton scatter remains an open issue. The inclusion of scattered photons within the energy window used for planar or SPECT data acquisition decreases the contrast of the image. While a number of methods for scatter correction have been proposed in the past, in this work, we propose and assess a novel, user-independent framework applying factor analysis (FA). Extensive Monte Carlo simulations for planar and tomographic imaging were performed using the SIMIND software. Furthermore, planar acquisition of two Petri dishes filled with 99mTc solutions and a Jaszczak phantom study (Data Spectrum Corporation, Durham, NC, USA) using a dual head gamma camera were performed. In order to use FA for scatter correction, we subdivided the applied energy window into a number of sub-windows, serving as input data. FA results in two factor images (photo-peak, scatter) and two corresponding factor curves (energy spectra). Planar and tomographic Jaszczak phantom gamma camera measurements were recorded. The tomographic data (simulations and measurements) were processed for each angular position resulting in a photo-peak and a scatter data set. The reconstructed transaxial slices of the Jaszczak phantom were quantified using an ImageJ plugin. The data obtained by FA showed good agreement with the energy spectra, photo-peak, and scatter images obtained in all Monte Carlo simulated data sets. For comparison, the standard dual-energy window (DEW) approach was additionally applied for scatter correction. FA in comparison with the DEW method results in significant improvements in image accuracy for both planar and tomographic data sets. FA can be used as a user-independent approach for scatter correction in nuclear medicine.
A high resolution Passive Flux Meter approach based on colorimetric responses
NASA Astrophysics Data System (ADS)
Chardi, K.; Dombrowski, K.; Cho, J.; Hatfield, K.; Newman, M.; Annable, M. D.
2016-12-01
Subsurface water and contaminant mass flux measurements are critical in determining risk, optimizing remediation strategies, and monitoring contaminant attenuation. The standard Passive Flux Meter, hereafter knows as a (PFM), is a well-developed device used for determining and monitoring rates of groundwater and contaminant mass flux in screened wells. The current PFM is a permeable device that contains granular activated carbon impregnated with alcohol tracers which is deployed in a flow field for a designated period of time. Once extracted, sampling requires laboratory analysis to quantify Darcy flux, which can be time consuming and have significant cost. To expedite test results, a modified PFM based on the image analysis of colorimetric responses, herein referred to as a colorimetric Passive Flux Meter (cPFM), was developed. Various dyes and sorbents were selected and evaluated to determine colorimetric response to water flow. Rhodamine, fluorescent yellow, fluorescent orange, and turmeric were the dye candidates while 100% wool and a 35% wool blend with 65% rayon were the sorbent candidates selected for use in the cPFM. Ultraviolet light image analysis was used to calculate average color intensity using ImageJ, a Java-based image processing program. These results were then used to quantify Darcy flux. Error ranges evaluated for Darcy flux using the cPFM are comparable to those with the standard, activated carbon based, PFM. The cPFM has the potential to accomplish the goal of obtaining high resolution Darcy flux data while eliminating high costs and analysis time. Implications of groundwater characteristics, such as PH and contaminant concentrations, on image analysis are to be tested through laboratory analysis followed by field testing of the cPFM.
2012-01-01
Background Analysis of ciliary function for assessment of patients suspected of primary ciliary dyskinesia (PCD) and for research studies of respiratory and ependymal cilia requires assessment of both ciliary beat pattern and beat frequency. While direct measurement of beat frequency from high-speed video recordings is the most accurate and reproducible technique it is extremely time consuming. The aim of this study was to develop a freely available automated method of ciliary beat frequency analysis from digital video (AVI) files that runs on open-source software (ImageJ) coupled to Microsoft Excel, and to validate this by comparison to the direct measuring high-speed video recordings of respiratory and ependymal cilia. These models allowed comparison to cilia beating between 3 and 52 Hz. Methods Digital video files of motile ciliated ependymal (frequency range 34 to 52 Hz) and respiratory epithelial cells (frequency 3 to 18 Hz) were captured using a high-speed digital video recorder. To cover the range above between 18 and 37 Hz the frequency of ependymal cilia were slowed by the addition of the pneumococcal toxin pneumolysin. Measurements made directly by timing a given number of individual ciliary beat cycles were compared with those obtained using the automated ciliaFA system. Results The overall mean difference (± SD) between the ciliaFA and direct measurement high-speed digital imaging methods was −0.05 ± 1.25 Hz, the correlation coefficient was shown to be 0.991 and the Bland-Altman limits of agreement were from −1.99 to 1.49 Hz for respiratory and from −2.55 to 3.25 Hz for ependymal cilia. Conclusions A plugin for ImageJ was developed that extracts pixel intensities and performs fast Fourier transformation (FFT) using Microsoft Excel. The ciliaFA software allowed automated, high throughput measurement of respiratory and ependymal ciliary beat frequency (range 3 to 52 Hz) and avoids operator error due to selection bias. We have included free access to the ciliaFA plugin and installation instructions in Additional file 1 accompanying this manuscript that other researchers may use. PMID:23351276
Mäkelä, Valtteri; Wahlström, Ronny; Holopainen-Mantila, Ulla; Kilpeläinen, Ilkka; King, Alistair W T
2018-05-14
Herein, we describe a new method of assessing the kinetics of dissolution of single fibers by dissolution under limited dissolving conditions. The dissolution is followed by optical microscopy under limited dissolving conditions. Videos of the dissolution were processed in ImageJ to yield kinetics for dissolution, based on the disappearance of pixels associated with intact fibers. Data processing was performed using the Python language, utilizing available scientific libraries. The methods of processing the data include clustering of the single fiber data, identifying clusters associated with different fiber types, producing average dissolution traces and also extraction of practical parameters, such as, time taken to dissolve 25, 50, 75, 95, and 99.5% of the clustered fibers. In addition to these simple parameters, exponential fitting was also performed yielding rate constants for fiber dissolution. Fits for sample and cluster averages were variable, although demonstrating first-order kinetics for dissolution overall. To illustrate this process, two reference pulps (a bleached softwood kraft pulp and a bleached hardwood pre-hydrolysis kraft pulp) and their cellulase-treated versions were analyzed. As expected, differences in the kinetics and dissolution mechanisms between these samples were observed. Our initial interpretations are presented, based on the combined mechanistic observations and single fiber dissolution kinetics for these different samples. While the dissolution mechanisms observed were similar to those published previously, the more direct link of mechanistic information with the kinetics improve our understanding of cell wall structure and pre-treatments, toward improved processability.
Three-Dimensional Quantification of Pore Space in Flocculated Sediments
NASA Astrophysics Data System (ADS)
Lawrence, Tom; Spencer, Kate; Bushby, Andy; Manning, Andrew
2017-04-01
Flocculated sediment structure plays a vital role in determining sediment dynamics within the water column in fresh and saline water bodies. The porosity of flocs contributes to their specific density and therefore their settling characteristics, and can also affect settling characteristics via through-flow. The process of settling and resuspension of flocculated material causes the formation of larger and more complex individual flocs, about which little is known quantitatively of the internal micro-structure and therefore porosity. Hydrological and sedimentological modelling software currently uses estimations of porosity, because it is difficult to capture and analyse flocs. To combat this, we use a novel microscopy method usually performed on biological material to scan the flocs, the output of which can be used to quantify the dimensions and arrangement of pores. This involves capturing flocculated sediment, staining the sample with heavy metal elements to highlight organic content in the Scanning Electron Microscope later, and finally setting the sample in resin. The overall research aim is to quantitatively characterise the dimensions and distribution of pore space in flocs in three dimensions. In order to gather data, Scanning Electron Microscopy and micro-Computed Tomography have been utilised to produce the necessary images to identify and quantify the pore space. The first objective is to determine the dimensional limits of pores in the structure (i.e. what area do they encapsulate? Are they interconnected or discreet?). This requires a repeatable definition to be established, so that all floc pore spaces can be quantified using the same parameters. The LabSFLOC settling column and dyes will be used as one possible method of determining the outer limits of the discreet pore space. LabSFLOC is a sediment settling column that uses a camera to record the flocs, enabling analysis of settling characteristics. The second objective is to develop a reliable method for quantifying the dimensions of the pores. The dimensions to be quantified are the long- and short-axis lengths, measured using ImageJ. The third objective will be to quantify the distribution of the pore space within the structure, utilising point-to-point measurements and distance from centre of the floc, again utilising software capable of providing accurate measurements between the centres of each pore within the structure. Preliminary data demonstrating pore dimensional limits and quantification will be presented. This will establish a definition of pore space based on limits of interaction between pore water and the water column, including experimental data from LabSFLOC, and visual representations of pore outer limits. Further to this, I will include some investigational data from ImageJ relating to the dimensions being measured for sub-aim 2. This information is vital in providing accurate and reliable information for hydrological and sedimentological model input, ultimately increasing the value of the outputs.
Čukuranović Kokoris, Jovana; Jovanović, Ivan; Pantović, Vukica; Krstić, Miljan; Stanojković, Milica; Milošević, Verica; Ugrenović, Slađana; Stojanović, Vesna
2017-02-01
The aim of this research was to quantify the changes in the morphology and density of the anterior pituitary folliculostellate (FS) and luteinizing hormone (LH) cells. Material was tissue of the pituitary gland of the 14 male cadavers. Tissue slices were immunohistochemically stained with monoclonal anti-LH antibody and polyclonal anti-S100 antibody for the detection of LH and FS cells, respectively. Digital images of the stained slices were afterwards morphometrically analyzed by ImageJ. Results of the morphometric analysis showed significant increase of the FS cells volume density in cases older than 70 years. Volume density of the LH cells did not significantly change, whereas their area significantly increased with age. Nucleocytoplasmic ratio of the LH cells gradually decreased and became significant after the age of 70. Finally, volume density of the FS cell significantly correlated with LH cells area and nucleocytoplasmic ratio. From all above cited, we concluded that in men, density and size of the FS cells increase with age. Long-term hypertrophy of the LH cells results in their functional decline after the age of 70. Strong correlation between FS cells and LH cells morphometric parameters might point to age-related interaction between these two cell groups. Copyright © 2016 Elsevier Ltd. All rights reserved.
Bogdanov, Anita; Endrész, Valeria; Urbán, Szabolcs; Lantos, Ildikó; Deák, Judit; Burián, Katalin; Önder, Kamil; Ayaydin, Ferhan; Balázs, Péter
2014-01-01
Chlamydiae are obligate intracellular bacteria that propagate in the inclusion, a specific niche inside the host cell. The standard method for counting chlamydiae is immunofluorescent staining and manual counting of chlamydial inclusions. High- or medium-throughput estimation of the reduction in chlamydial inclusions should be the basis of testing antichlamydial compounds and other drugs that positively or negatively influence chlamydial growth, yet low-throughput manual counting is the common approach. To overcome the time-consuming and subjective manual counting, we developed an automatic inclusion-counting system based on a commercially available DNA chip scanner. Fluorescently labeled inclusions are detected by the scanner, and the image is processed by ChlamyCount, a custom plug-in of the ImageJ software environment. ChlamyCount was able to measure the inclusion counts over a 1-log-unit dynamic range with a high correlation to the theoretical counts. ChlamyCount was capable of accurately determining the MICs of the novel antimicrobial compound PCC00213 and the already known antichlamydial antibiotics moxifloxacin and tetracycline. ChlamyCount was also able to measure the chlamydial growth-altering effect of drugs that influence host-bacterium interaction, such as gamma interferon, DEAE-dextran, and cycloheximide. ChlamyCount is an easily adaptable system for testing antichlamydial antimicrobials and other compounds that influence Chlamydia-host interactions. PMID:24189259
Natchimuthu, V; Thomas, Sabu; Ramalingam, Murugan; Ravi, S
2017-09-01
Lennox-Gastaut syndrome (LGS) is commonly characterized by a triad of features including multiple seizure types, intellectual disability or regression. LGS type of seizures is epilepsy which is due to abnormal vibrations occurring in seizures. During the time of such abnormal vibrations, both the seizures and the lungs suffer a lack in oxygen content to a considerable extent. This results in prolonged vibrations and loses of nervous control. As a neuro-lung protective strategy, a novel attempt has been made to enrich both seizures and lungs with oxygen content through the support of Perfluorodecalin (an excellent oxygen carrier) C 10 F 18 (PFD) and Perfluorohexane C 6 F 14 (PFH) along with an enhancement in the antiepileptic activity by the two chosen antiepileptic drugs (AEDs) Carbamazepine (CBZ) and Benzodiazepine (BDZ). Perfluorodecalin C 10 F 18 (PFD) and Perfluorohexane C 6 F 14 (PFH) emulsions were prepared by sonication process with combination of nonionic emulsifier, Lecithin (l-α-phosphatidylcholine) as a surfactant in Aqueous phase medium. These emulsions were mixed with Carbamazepine (CBZ) and Benzodiazepine (BDZ) drugs maintained at a temperature of about -20°C to 20°C and were set to slow evaporation process. The products are subjected to Optical microscope, Transmission electron microscopy (TEM) and Scanning Electron Microscope (SEM) - Energy dispersive X-ray Spectroscopy (EDS). Study reveals the co-existence of fluorine and drug ensuring the oxygen uptake by the drug. Morphology of TEM, Optical microscopic images and the particle diameter estimated through Image_J confirms this analysis. Copyright © 2017 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ibrahim, Illani; Sekak, Khairunnadim Ahmad; Hasbullah, Norazurean
Researches on the fabrication of nanostructured based membrane have attracted great attention amongst scientists due to their wide potential applications on medical application. In this work, Chitosan and Aloe Vera sol-gel solution were electrospun using 20 kV DC supply at room temperature. Morphological structure and functional group of nanofibers were characterized using field emission scanning electron microscopy (FESEM) and Fourier-transform infrared spectroscopy (FT-IR) respectively. The optimum parameter obtained at 90% concentration of acetic acid, 0.3 ml/h of solution flow rate and 10 cm distance of nozzle to collector. The fiber diameters were analyzed using the ImageJ software. Average diameters of the Chitosan/Aloe Veramore » composite nanofibers is 183nm in ranges of 140–260nm.« less
NASA Astrophysics Data System (ADS)
Ibrahim, Illani; Sekak, Khairunnadim Ahmad; Hasbullah, Norazurean
2015-08-01
Researches on the fabrication of nanostructured based membrane have attracted great attention amongst scientists due to their wide potential applications on medical application. In this work, Chitosan and Aloe Vera sol-gel solution were electrospun using 20 kV DC supply at room temperature. Morphological structure and functional group of nanofibers were characterized using field emission scanning electron microscopy (FESEM) and Fourier-transform infrared spectroscopy (FT-IR) respectively. The optimum parameter obtained at 90% concentration of acetic acid, 0.3 ml/h of solution flow rate and 10 cm distance of nozzle to collector. The fiber diameters were analyzed using the ImageJ software. Average diameters of the Chitosan/Aloe Vera composite nanofibers is 183nm in ranges of 140-260nm.
Automated Functional Analysis of Astrocytes from Chronic Time-Lapse Calcium Imaging Data
Wang, Yinxue; Shi, Guilai; Miller, David J.; Wang, Yizhi; Wang, Congchao; Broussard, Gerard; Wang, Yue; Tian, Lin; Yu, Guoqiang
2017-01-01
Recent discoveries that astrocytes exert proactive regulatory effects on neural information processing and that they are deeply involved in normal brain development and disease pathology have stimulated broad interest in understanding astrocyte functional roles in brain circuit. Measuring astrocyte functional status is now technically feasible, due to recent advances in modern microscopy and ultrasensitive cell-type specific genetically encoded Ca2+ indicators for chronic imaging. However, there is a big gap between the capability of generating large dataset via calcium imaging and the availability of sophisticated analytical tools for decoding the astrocyte function. Current practice is essentially manual, which not only limits analysis throughput but also risks introducing bias and missing important information latent in complex, dynamic big data. Here, we report a suite of computational tools, called Functional AStrocyte Phenotyping (FASP), for automatically quantifying the functional status of astrocytes. Considering the complex nature of Ca2+ signaling in astrocytes and low signal to noise ratio, FASP is designed with data-driven and probabilistic principles, to flexibly account for various patterns and to perform robustly with noisy data. In particular, FASP explicitly models signal propagation, which rules out the applicability of tools designed for other types of data. We demonstrate the effectiveness of FASP using extensive synthetic and real data sets. The findings by FASP were verified by manual inspection. FASP also detected signals that were missed by purely manual analysis but could be confirmed by more careful manual examination under the guidance of automatic analysis. All algorithms and the analysis pipeline are packaged into a plugin for Fiji (ImageJ), with the source code freely available online at https://github.com/VTcbil/FASP. PMID:28769780
Automated Functional Analysis of Astrocytes from Chronic Time-Lapse Calcium Imaging Data.
Wang, Yinxue; Shi, Guilai; Miller, David J; Wang, Yizhi; Wang, Congchao; Broussard, Gerard; Wang, Yue; Tian, Lin; Yu, Guoqiang
2017-01-01
Recent discoveries that astrocytes exert proactive regulatory effects on neural information processing and that they are deeply involved in normal brain development and disease pathology have stimulated broad interest in understanding astrocyte functional roles in brain circuit. Measuring astrocyte functional status is now technically feasible, due to recent advances in modern microscopy and ultrasensitive cell-type specific genetically encoded Ca 2+ indicators for chronic imaging. However, there is a big gap between the capability of generating large dataset via calcium imaging and the availability of sophisticated analytical tools for decoding the astrocyte function. Current practice is essentially manual, which not only limits analysis throughput but also risks introducing bias and missing important information latent in complex, dynamic big data. Here, we report a suite of computational tools, called Functional AStrocyte Phenotyping (FASP), for automatically quantifying the functional status of astrocytes. Considering the complex nature of Ca 2+ signaling in astrocytes and low signal to noise ratio, FASP is designed with data-driven and probabilistic principles, to flexibly account for various patterns and to perform robustly with noisy data. In particular, FASP explicitly models signal propagation, which rules out the applicability of tools designed for other types of data. We demonstrate the effectiveness of FASP using extensive synthetic and real data sets. The findings by FASP were verified by manual inspection. FASP also detected signals that were missed by purely manual analysis but could be confirmed by more careful manual examination under the guidance of automatic analysis. All algorithms and the analysis pipeline are packaged into a plugin for Fiji (ImageJ), with the source code freely available online at https://github.com/VTcbil/FASP.
Pitakpawasutthi, Yamon; Thitikornpong, Worathat; Palanuvej, Chanida; Ruangrungsi, Nijsiri
2016-01-01
Chromolaena odorata (L.) R. M. King and H. Rob. is a Thai medicinal plant used for the treatment of wounds, rashes, diabetes, and insect repellent. The leaves of C. odorata were collected from 10 different sources throughout Thailand. The chemical constituents of essential oils were hydro-distilled from the leaves and were analyzed by gas chromatography-mass spectrometry. Chlorogenic acid contents were determined by thin-layer chromatography (TLC) - densitometry with winCATS software and TLC image analysis with ImageJ software. The TLC plate was developed in the mobile phase that consisted of ethyl acetate:water:formic acid (17:3:2). Antioxidant activities were examined by 1,1-diphenyl-2-picryl hydrazyl (DPPH) radical scavenging and β-carotene bleaching assays. C. odorata essential oil has shown the major components of pregeijerene, dauca-5, 8-diene, (E)-caryophyllene, β-pinene, and α-pinene. The chlorogenic acid content of C. odorata leaves was determined by TLC-densitometry and TLC image analysis. Results have shown that TLC-densitometry and TLC image analysis method were not statistically significantly different. DPPH radical scavenging and β-carotene bleaching assays of ethanolic extract of C. odorata leaves showed its antioxidant potential. PMID:27144150
Dispersal of Volcanic Ash on Mars: Ash Grain Shape Analysis
NASA Astrophysics Data System (ADS)
Langdalen, Z.; Fagents, S. A.; Fitch, E. P.
2017-12-01
Many ash dispersal models use spheres as ash-grain analogs in drag calculations. These simplifications introduce inaccuracies in the treatment of drag coefficients, leading to inaccurate settling velocities and dispersal predictions. Therefore, we are investigating the use of a range of shape parameters, calculated using grain dimensions, to derive a better representation of grain shape and effective grain cross-sectional area. Specifically, our goal is to apply our results to the modeling of ash deposition to investigate the proposed volcanic origin of certain fine-grained deposits on Mars. Therefore, we are documenting the dimensions and shapes of ash grains from terrestrial subplinian to plinian deposits, in eight size divisions from 2 mm to 16 μm, employing a high resolution optical microscope. The optical image capture protocol provides an accurate ash grain outline by taking multiple images at different focus heights prior to combining them into a composite image. Image composite mosaics are then processed through ImageJ, a robust scientific measurement software package, to calculate a range of dimensionless shape parameters. Since ash grains rotate as they fall, drag forces act on a changing cross-sectional area. Therefore, we capture images and calculate shape parameters of each grain positioned in three orthogonal orientations. We find that the difference between maximum and minimum aspect ratios of the three orientations of a given grain best quantifies the degree of elongation of that grain. However, the average aspect ratio calculated for each grain provides a good representation of relative differences among grains. We also find that convexity provides the best representation of surface irregularity. For both shape parameters, natural ash grains display notably different shape parameter values than sphere analogs. Therefore, Mars ash dispersal modeling that incorporates shape parameters will provide more realistic predictions of deposit extents because volcanic ash-grain morphologies differ substantially from simplified geometric shapes.
Lahuerta-Zamora, Luis; Mellado-Romero, Ana M
2017-06-01
A new system for continuous flow chemiluminescence detection, based on the use of a simple and low-priced lens-free digital camera (with complementary metal oxide semiconductor technology) as a detector, is proposed for the quantitative determination of paracetamol in commercial pharmaceutical formulations. Through the camera software, AVI video files of the chemiluminescence emission are captured and then, using friendly ImageJ public domain software (from National Institutes for Health), properly processed in order to extract the analytical information. The calibration graph was found to be linear over the range 0.01-0.10 mg L -1 and over the range 1.0-100.0 mg L -1 of paracetamol, the limit of detection being 10 μg L -1 . No significative interferences were found. Paracetamol was determined in three different pharmaceutical formulations: Termalgin®, Efferalgan® and Gelocatil®. The obtained results compared well with those declared on the formulation label and with those obtained through the official analytical method of British Pharmacopoeia. Graphical abstract Abbreviated scheme of the new chemiluminescence detection system proposed in this paper.
Automated Axon Counting in Rodent Optic Nerve Sections with AxonJ.
Zarei, Kasra; Scheetz, Todd E; Christopher, Mark; Miller, Kathy; Hedberg-Buenz, Adam; Tandon, Anamika; Anderson, Michael G; Fingert, John H; Abràmoff, Michael David
2016-05-26
We have developed a publicly available tool, AxonJ, which quantifies the axons in optic nerve sections of rodents stained with paraphenylenediamine (PPD). In this study, we compare AxonJ's performance to human experts on 100x and 40x images of optic nerve sections obtained from multiple strains of mice, including mice with defects relevant to glaucoma. AxonJ produced reliable axon counts with high sensitivity of 0.959 and high precision of 0.907, high repeatability of 0.95 when compared to a gold-standard of manual assessments and high correlation of 0.882 to the glaucoma damage staging of a previously published dataset. AxonJ allows analyses that are quantitative, consistent, fully-automated, parameter-free, and rapid on whole optic nerve sections at 40x. As a freely available ImageJ plugin that requires no highly specialized equipment to utilize, AxonJ represents a powerful new community resource augmenting studies of the optic nerve using mice.
Porphyrin involvement in redshift fluorescence in dentin decay
NASA Astrophysics Data System (ADS)
Slimani, A.; Panayotov, I.; Levallois, B.; Cloitre, T.; Gergely, C.; Bec, N.; Larroque, C.; Tassery, H.; Cuisinier, F.
2014-05-01
The aim of this study was to evaluate the porphyrin involvement in the red fluorescence observed in dental caries with Soprolife® light-induced fluorescence camera in treatments mode (SOPRO, ACTEON Group, La Ciotat, France) and Vistacam® camera (DÜRR DENTAL AG, Bietigheim-Bissingen, Germany). The International Caries Detection and Assessment System (ICDAS) was used to rand the samples. Human teeth cross-sections, ranked from ICDAS score 0 to 6, were examined by epi-fluorescence microscopy and Confocal Raman microscopy. Comparable studies were done with Protoporphyrin IX, Porphyrin I and Pentosidine solutions. An RGB analysis of Soprolife® images was performed using ImageJ Software (1.46r, National Institutes of Health, USA). Fluorescence spectroscopy and MicroRaman spectroscopy revealed the presence of Protoporphyrin IX, in carious enamel, dentin and dental plaque. However, the presence of porphyrin I and pentosidine cannot be excluded. The results indicated that not only porphyrin were implicated in the red fluorescence, Advanced Glygation Endproducts (AGEs) of the Maillard reaction also contributed to this phenomenon.
Automated Axon Counting in Rodent Optic Nerve Sections with AxonJ
NASA Astrophysics Data System (ADS)
Zarei, Kasra; Scheetz, Todd E.; Christopher, Mark; Miller, Kathy; Hedberg-Buenz, Adam; Tandon, Anamika; Anderson, Michael G.; Fingert, John H.; Abràmoff, Michael David
2016-05-01
We have developed a publicly available tool, AxonJ, which quantifies the axons in optic nerve sections of rodents stained with paraphenylenediamine (PPD). In this study, we compare AxonJ’s performance to human experts on 100x and 40x images of optic nerve sections obtained from multiple strains of mice, including mice with defects relevant to glaucoma. AxonJ produced reliable axon counts with high sensitivity of 0.959 and high precision of 0.907, high repeatability of 0.95 when compared to a gold-standard of manual assessments and high correlation of 0.882 to the glaucoma damage staging of a previously published dataset. AxonJ allows analyses that are quantitative, consistent, fully-automated, parameter-free, and rapid on whole optic nerve sections at 40x. As a freely available ImageJ plugin that requires no highly specialized equipment to utilize, AxonJ represents a powerful new community resource augmenting studies of the optic nerve using mice.
Radiological and histopathological evaluation of experimentally-induced periapical lesion in rats
TEIXEIRA, Renata Cordeiro; RUBIRA, Cassia Maria Fischer; ASSIS, Gerson Francisco; LAURIS, José Roberto Pereira; CESTARI, Tania Mary; RUBIRA-BULLEN, Izabel Regina Fischer
2011-01-01
Objective This study evaluated experimentally-induced periapical bone loss sites using digital radiographic and histopathologic parameters. Material and Methods Twenty-seven Wistar rats were submitted to coronal opening of their mandibular right first molars. They were radiographed at 2, 15 and 30 days after the operative procedure by two digital radiographic storage phosphor plates (Digora®). The images were analyzed by creating a region of interest at the periapical region of each tooth (ImageJ) and registering the corresponding pixel values. After the sacrifice, the specimens were submitted to microscopic analysis in order to confirm the pulpal and periapical status of the tooth. Results There was significant statistically difference between the control and test sides in all the experimental periods regarding the pixel values (two-way ANOVA; p<0.05). Conclusions The microscopic analysis proved that a periapical disease development occurred during the experimental periods with an evolution from pulpal necrosis to periapical bone resorption. PMID:21922123
de Oliveira, Marcus Vinicius Linhares; Santos, António Carvalho; Paulo, Graciano; Campos, Paulo Sergio Flores; Santos, Joana
2017-06-01
The purpose of this study was to apply a newly developed free software program, at low cost and with minimal time, to evaluate the quality of dental and maxillofacial cone-beam computed tomography (CBCT) images. A polymethyl methacrylate (PMMA) phantom, CQP-IFBA, was scanned in 3 CBCT units with 7 protocols. A macro program was developed, using the free software ImageJ, to automatically evaluate the image quality parameters. The image quality evaluation was based on 8 parameters: uniformity, the signal-to-noise ratio (SNR), noise, the contrast-to-noise ratio (CNR), spatial resolution, the artifact index, geometric accuracy, and low-contrast resolution. The image uniformity and noise depended on the protocol that was applied. Regarding the CNR, high-density structures were more sensitive to the effect of scanning parameters. There were no significant differences between SNR and CNR in centered and peripheral objects. The geometric accuracy assessment showed that all the distance measurements were lower than the real values. Low-contrast resolution was influenced by the scanning parameters, and the 1-mm rod present in the phantom was not depicted in any of the 3 CBCT units. Smaller voxel sizes presented higher spatial resolution. There were no significant differences among the protocols regarding artifact presence. This software package provided a fast, low-cost, and feasible method for the evaluation of image quality parameters in CBCT.
EarthTutor: An Interactive Intelligent Tutoring System for Remote Sensing
NASA Astrophysics Data System (ADS)
Bell, A. M.; Parton, K.; Smith, E.
2005-12-01
Earth science classes in colleges and high schools use a variety of satellite image processing software to teach earth science and remote sensing principles. However, current tutorials for image processing software are often paper-based or lecture-based and do not take advantage of the full potential of the computer context to teach, immerse, and stimulate students. We present EarthTutor, an adaptive, interactive Intelligent Tutoring System (ITS) being built for NASA (National Aeronautics and Space Administration) that is integrated directly with an image processing application. The system aims to foster the use of satellite imagery in classrooms and encourage inquiry-based, hands-on earth science scientific study by providing students with an engaging imagery analysis learning environment. EarthTutor's software is available as a plug-in to ImageJ, a free image processing system developed by the NIH (National Institute of Health). Since it is written in Java, it can be run on almost any platform and also as an applet from the Web. Labs developed for EarthTutor combine lesson content (such as HTML web pages) with interactive activities and questions. In each lab the student learns to measure, calibrate, color, slice, plot and otherwise process and analyze earth science imagery. During the activities, EarthTutor monitors students closely as they work, which allows it to provide immediate feedback that is customized to a particular student's needs. As the student moves through the labs, EarthTutor assesses the student, and tailors the presentation of the content to a student's demonstrated skill level. EarthTutor's adaptive approach is based on emerging Artificial Intelligence (AI) research. Bayesian networks are employed to model a student's proficiency with different earth science and image processing concepts. Agent behaviors are used to track the student's progress through activities and provide guidance when a student encounters difficulty. Through individual feedback and adaptive instruction, EarthTutor aims to offer the benefits of a one-on-one human instructor in a cost-effective, easy-to-use application. We are currently working with remote sensing experts to develop EarthTutor labs for diverse earth science subjects such as global vegetation, stratospheric ozone, oceanography, polar sea ice and natural hazards. These labs will be packaged with the first public release of EarthTutor in December 2005. Custom labs can be designed with the EarthTutor authoring tool. The tool is basic enough to allow teachers to construct tutorials to fit their classroom's curriculum and locale, but also powerful enough to allow advanced users to create highly-interactive labs. Preliminary results from an ongoing pilot study demonstrate that the EarthTutor system is effective and enjoyable teaching tool, relative to traditional satellite imagery teaching methods.
Assessing spatial and temporal snowpack evolution and melt with time-lapse photography
NASA Astrophysics Data System (ADS)
Bush, C. E.; Ewers, B. E.; Beverly, D.; Speckman, H. N.; Hyde, K.; Ohara, N.
2015-12-01
Snowpack supplies and stores water for many ecosystems of the greater Rocky Mountain region. In Wyoming the snowpack supplies water to 18 states east and west of the Continental Divide. The spatial variability in physical and biological processes creates a heterogeneous pattern of snow evolution. Understanding these processes within individual plots and throughout the entire watershed increases the predictive power of snow distribution, melt rates and contribution to streamflow. However, on site sampling of snow can be an expensive and arduous process. The objective of this experiment was to quantify spatial and temporal patterns of snowpack evolution and melt rates while minimizing perturbations to snowpack through the use of time-lapse photography via trail cameras. Field cameras were assessed as a method to quantify snow depths throughout the 120 ha No Name watershed at approximately 3000 m elevation in central Wyoming. RGB trail cameras were installed at three systematically chosen sites within the watershed to correlate physical and biological drivers of snow distribution. Five stakes were placed in each site in heterogeneous spots that remained in the frame of the camera. Stakes were divided into five centimeter increments, alternating black and white bars, with red bars denoting each half meter. Images were then taken at two-hour intervals over a period of three-months and analyzed with the ImageJ program. Snowpack distributions, as well as melt rates, were variable at both the plot and watershed scales. Meteorological and physical drivers, primarily topography and radiation, accounted for the greatest variability when comparing among plot across the watershed; however, LAI and soil and air temperature were the most significant drivers within plots. Snow-melt rate increased as soils and course woody debris became exposed increasing ground and soil temperature. These data will improve process model predictions of streamflow from the watershed.
FMAj: a tool for high content analysis of muscle dynamics in Drosophila metamorphosis.
Kuleesha, Yadav; Puah, Wee Choo; Lin, Feng; Wasser, Martin
2014-01-01
During metamorphosis in Drosophila melanogaster, larval muscles undergo two different developmental fates; one population is removed by cell death, while the other persistent subset undergoes morphological remodeling and survives to adulthood. Thanks to the ability to perform live imaging of muscle development in transparent pupae and the power of genetics, metamorphosis in Drosophila can be used as a model to study the regulation of skeletal muscle mass. However, time-lapse microscopy generates sizeable image data that require new tools for high throughput image analysis. We performed targeted gene perturbation in muscles and acquired 3D time-series images of muscles in metamorphosis using laser scanning confocal microscopy. To quantify the phenotypic effects of gene perturbations, we designed the Fly Muscle Analysis tool (FMAj) which is based on the ImageJ and MySQL frameworks for image processing and data storage, respectively. The image analysis pipeline of FMAj contains three modules. The first module assists in adding annotations to time-lapse datasets, such as genotypes, experimental parameters and temporal reference points, which are used to compare different datasets. The second module performs segmentation and feature extraction of muscle cells and nuclei. Users can provide annotations to the detected objects, such as muscle identities and anatomical information. The third module performs comparative quantitative analysis of muscle phenotypes. We applied our tool to the phenotypic characterization of two atrophy related genes that were silenced by RNA interference. Reduction of Drosophila Tor (Target of Rapamycin) expression resulted in enhanced atrophy compared to control, while inhibition of the autophagy factor Atg9 caused suppression of atrophy and enlarged muscle fibers of abnormal morphology. FMAj enabled us to monitor the progression of atrophic and hypertrophic phenotypes of individual muscles throughout metamorphosis. We designed a new tool to visualize and quantify morphological changes of muscles in time-lapse images of Drosophila metamorphosis. Our in vivo imaging experiments revealed that evolutionarily conserved genes involved in Tor signalling and autophagy, perform similar functions in regulating muscle mass in mammals and Drosophila. Extending our approach to a genome-wide scale has the potential to identify new genes involved in muscle size regulation.
FMAj: a tool for high content analysis of muscle dynamics in Drosophila metamorphosis
2014-01-01
Background During metamorphosis in Drosophila melanogaster, larval muscles undergo two different developmental fates; one population is removed by cell death, while the other persistent subset undergoes morphological remodeling and survives to adulthood. Thanks to the ability to perform live imaging of muscle development in transparent pupae and the power of genetics, metamorphosis in Drosophila can be used as a model to study the regulation of skeletal muscle mass. However, time-lapse microscopy generates sizeable image data that require new tools for high throughput image analysis. Results We performed targeted gene perturbation in muscles and acquired 3D time-series images of muscles in metamorphosis using laser scanning confocal microscopy. To quantify the phenotypic effects of gene perturbations, we designed the Fly Muscle Analysis tool (FMAj) which is based on the ImageJ and MySQL frameworks for image processing and data storage, respectively. The image analysis pipeline of FMAj contains three modules. The first module assists in adding annotations to time-lapse datasets, such as genotypes, experimental parameters and temporal reference points, which are used to compare different datasets. The second module performs segmentation and feature extraction of muscle cells and nuclei. Users can provide annotations to the detected objects, such as muscle identities and anatomical information. The third module performs comparative quantitative analysis of muscle phenotypes. We applied our tool to the phenotypic characterization of two atrophy related genes that were silenced by RNA interference. Reduction of Drosophila Tor (Target of Rapamycin) expression resulted in enhanced atrophy compared to control, while inhibition of the autophagy factor Atg9 caused suppression of atrophy and enlarged muscle fibers of abnormal morphology. FMAj enabled us to monitor the progression of atrophic and hypertrophic phenotypes of individual muscles throughout metamorphosis. Conclusions We designed a new tool to visualize and quantify morphological changes of muscles in time-lapse images of Drosophila metamorphosis. Our in vivo imaging experiments revealed that evolutionarily conserved genes involved in Tor signalling and autophagy, perform similar functions in regulating muscle mass in mammals and Drosophila. Extending our approach to a genome-wide scale has the potential to identify new genes involved in muscle size regulation. PMID:25521203
NASA Astrophysics Data System (ADS)
Kocaoglu, Omer P.; Lee, Sangyeol; Jonnal, Ravi S.; Wang, Qiang; Herde, Ashley E.; Besecker, Jason; Gao, Weihua; Miller, Donald T.
2011-03-01
Optical coherence tomography with adaptive optics (AO-OCT) is a highly sensitive, noninvasive method for 3D imaging of the microscopic retina. The purpose of this study is to advance AO-OCT technology by enabling repeated imaging of cone photoreceptors over extended periods of time (days). This sort of longitudinal imaging permits monitoring of 3D cone dynamics in both normal and diseased eyes, in particular the physiological processes of disc renewal and phagocytosis, which are disrupted by retinal diseases such as age related macular degeneration and retinitis pigmentosa. For this study, the existing AO-OCT system at Indiana underwent several major hardware and software improvements to optimize system performance for 4D cone imaging. First, ultrahigh speed imaging was realized using a Basler Sprint camera. Second, a light source with adjustable spectrum was realized by integration of an Integral laser (Femto Lasers, λc=800nm, ▵λ=160nm) and spectral filters in the source arm. For cone imaging, we used a bandpass filter with λc=809nm and ▵λ=81nm (2.6 μm nominal axial resolution in tissue, and 167 KHz A-line rate using 1,408 px), which reduced the impact of eye motion compared to previous AO-OCT implementations. Third, eye motion artifacts were further reduced by custom ImageJ plugins that registered (axially and laterally) the volume videos. In two subjects, cone photoreceptors were imaged and tracked over a ten day period and their reflectance and outer segment (OS) lengths measured. High-speed imaging and image registration/dewarping were found to reduce eye motion to a fraction of a cone width (1 μm root mean square). The pattern of reflections in the cones was found to change dramatically and occurred on a spatial scale well below the resolution of clinical instruments. Normalized reflectance of connecting cilia (CC) and OS posterior tip (PT) of an exemplary cone was 54+/-4, 47+/-4, 48+/-6, 50+/-5, 56+/-1% and 46+/-4, 53+/-4, 52+/-6, 50+/-5, 44+/-1% for days #1,3,6,8,10 respectively. OS length of the same cone was 28.9, 26.4, 26.4, 30.6, and 28.1 ìm for days #1,3,6,8,10 respectively. It is plausible these changes are an optical correlate of the natural process of OS renewal and shedding.
Mazzoli, Alida; Moriconi, Giacomo
2014-12-01
The waste management of glass fiber reinforced polymer (GRP) materials, in particular those made with thermosetting resins, is a critical issue for the composites industry because these materials cannot be reprocessed. Therefore, most thermosetting GRP waste is presently sent to landfill, in spite of the significant environmental impact caused by their disposal in this way. The limited GRP waste recycling worldwide is mostly due to its intrinsic thermosetting properties, lack of characterization data and unavailability of viable recycling and recovery routes. One of the possibility for re-using GRP industrial by-product is in form of powder as a partial aggregate replacement or filler addition in cement based composites for applications in sustainable construction materials and technologies. However, the feasibility of this kind of reutilization strongly depends on the morphology and particle size distribution of a powder made up of polymer granules and glass fibers. In the present study, the use of image analysis method, based on scanning electron microscopy (SEM) and ImageJ processing program, is proposed in order to evaluate the morphology of the particles and measure the particle size and size distribution of fine GRP waste powder. The obtained results show a great potential of such a method in order to be considered as a standardized method of measurement and analysis in order to characterize the grain size and size distribution of GRP particles before exploiting any compatibility issue for its recycling management. Copyright © 2014 Elsevier Ltd. All rights reserved.
Wax Modeling and Image Analysis for Classroom-Scale Lava Flow Simulations.
NASA Astrophysics Data System (ADS)
Rader, E. L.; Clarke, A. B.; Vanderkluysen, L.
2016-12-01
The use of polyethylene glycol wax (PEG 600) as an analog for lava allows for a visual representation of the complex physical process occurring in natural lava flows, including cooling, breakouts, and crust and lobe formation. We used a series of cameras positioned around a tank filled with chilled water as a lab bench to observe and quantify lava flow morphology and motion. A peristaltic pump connected to a vent at the base of the tank delivered dyed wax simulating effusive eruptions similar to those of Kilauea in Hawai`i. By varying the eruptive conditions such as wax temperature and eruption rate, students can observe how the crust forms on wax flows, how different textures result, and how a flow field evolves with time. Recorded footage of the same `eruption' can then be quantitatively analyzed using free software like ImageJ and Tracker to quantify time-series of spreading rate, change in height, and appearance of different surface morphologies. Additional dye colors can be added periodically to further illustrate how lava is transported from the vent to the periphery of a flow field (e.g., through a tube system). Data collected from this activity can be compared to active lava flow footage from Hawai`i and with numerical models of lava flow propagation, followed by discussions of the application of these data and concepts to predicting the behavior of lava in hazard management situations and interpreting paleomagnetic, petrologic, and mapping of older eruptions.
Reyes, D R; Halter, M; Hwang, J
2015-07-01
The characterization of internal structures in a polymeric microfluidic device, especially of a final product, will require a different set of optical metrology tools than those traditionally used for microelectronic devices. We demonstrate that optical coherence tomography (OCT) imaging is a promising technique to characterize the internal structures of poly(methyl methacrylate) devices where the subsurface structures often cannot be imaged by conventional wide field optical microscopy. The structural details of channels in the devices were imaged with OCT and analyzed with an in-house written ImageJ macro in an effort to identify the structural details of the channel. The dimensional values obtained with OCT were compared with laser-scanning confocal microscopy images of channels filled with a fluorophore solution. Attempts were also made using confocal reflectance and interferometry microscopy to measure the channel dimensions, but artefacts present in the images precluded quantitative analysis. OCT provided the most accurate estimates for the channel height based on an analysis of optical micrographs obtained after destructively slicing the channel with a microtome. OCT may be a promising technique for the future of three-dimensional metrology of critical internal structures in lab-on-a-chip devices because scans can be performed rapidly and noninvasively prior to their use. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.
Reilly, Douglas K.; Lawler, Daniel E.; Albrecht, Dirk R.; Srinivasan, Jagan
2017-01-01
The use of calcium indicators has greatly enhanced our understanding of neural dynamics and regulation. The nematode Caenorhabditis elegans, with its completely mapped nervous system and transparent anatomy, presents an ideal model for understanding real-time neural dynamics using calcium indicators. In combination with microfluidic technologies and experimental designs, calcium-imaging studies using these indicators are performed in both free-moving and trapped animals. However, most previous studies utilizing trapping devices, such as the olfactory chip described in Chronis et al., have devices designed for use in the more common hermaphrodite, as the less common male is both morphologically and structurally dissimilar. An adapted olfactory chip was designed and fabricated for increased efficiency in male neuronal imaging with using young adult animals. A turn was incorporated into the worm loading port to rotate the animals and to allow for the separation of the individual neurons within a bilateral pair in 2D imaging. Worms are exposed to a controlled flow of odorant within the microfluidic device, as described in previous hermaphrodite studies. Calcium transients are then analyzed using the open-source software ImageJ. The procedure described herein should allow for an increased amount of male-based C. elegans calcium imaging studies, deepening our understanding of the mechanisms of sex-specific neuronal signaling. PMID:28930991
Evaluation of DICOM viewer software for workflow integration in clinical trials
NASA Astrophysics Data System (ADS)
Haak, Daniel; Page, Charles E.; Kabino, Klaus; Deserno, Thomas M.
2015-03-01
The digital imaging and communications in medicine (DICOM) protocol is nowadays the leading standard for capture, exchange and storage of image data in medical applications. A broad range of commercial, free, and open source software tools supporting a variety of DICOM functionality exists. However, different from patient's care in hospital, DICOM has not yet arrived in electronic data capture systems (EDCS) for clinical trials. Due to missing integration, even just the visualization of patient's image data in electronic case report forms (eCRFs) is impossible. Four increasing levels for integration of DICOM components into EDCS are conceivable, raising functionality but also demands on interfaces with each level. Hence, in this paper, a comprehensive evaluation of 27 DICOM viewer software projects is performed, investigating viewing functionality as well as interfaces for integration. Concerning general, integration, and viewing requirements the survey involves the criteria (i) license, (ii) support, (iii) platform, (iv) interfaces, (v) two-dimensional (2D) and (vi) three-dimensional (3D) image viewing functionality. Optimal viewers are suggested for applications in clinical trials for 3D imaging, hospital communication, and workflow. Focusing on open source solutions, the viewers ImageJ and MicroView are superior for 3D visualization, whereas GingkoCADx is advantageous for hospital integration. Concerning workflow optimization in multi-centered clinical trials, we suggest the open source viewer Weasis. Covering most use cases, an EDCS and PACS interconnection with Weasis is suggested.
Automated image analysis of placental villi and syncytial knots in histological sections.
Kidron, Debora; Vainer, Ifat; Fisher, Yael; Sharony, Reuven
2017-05-01
Delayed villous maturation and accelerated villous maturation diagnosed in histologic sections are morphologic manifestations of pathophysiological conditions. The inter-observer agreement among pathologists in assessing these conditions is moderate at best. We investigated whether automated image analysis of placental villi and syncytial knots could improve standardization in diagnosing these conditions. Placentas of antepartum fetal death at or near term were diagnosed as normal, delayed or accelerated villous maturation. Histologic sections of 5 cases per group were photographed at ×10 magnification. Automated image analysis of villi and syncytial knots was performed, using ImageJ public domain software. Analysis of hundreds of histologic images was carried out within minutes on a personal computer, using macro commands. Compared to normal placentas, villi from delayed maturation were larger and fewer, with fewer and smaller syncytial knots. Villi from accelerated maturation were smaller. The data were further analyzed according to horizontal placental zones and groups of villous size. Normal placentas can be discriminated from placentas of delayed or accelerated villous maturation using automated image analysis. Automated image analysis of villi and syncytial knots is not equivalent to interpretation by the human eye. Each method has advantages and disadvantages in assessing the 2-dimensional histologic sections representing the complex, 3-dimensional villous tree. Image analysis of placentas provides quantitative data that might help in standardizing and grading of placentas for diagnostic and research purposes. Copyright © 2017 Elsevier Ltd. All rights reserved.
Sack, Lawren; Caringella, Marissa; Scoffoni, Christine; Mason, Chase; Rawls, Michael; Markesteijn, Lars; Poorter, Lourens
2014-10-01
Leaf vein length per unit leaf area (VLA; also known as vein density) is an important determinant of water and sugar transport, photosynthetic function, and biomechanical support. A range of software methods are in use to visualize and measure vein systems in cleared leaf images; typically, users locate veins by digital tracing, but recent articles introduced software by which users can locate veins using thresholding (i.e. based on the contrasting of veins in the image). Based on the use of this method, a recent study argued against the existence of a fixed VLA value for a given leaf, proposing instead that VLA increases with the magnification of the image due to intrinsic properties of the vein system, and recommended that future measurements use a common, low image magnification for measurements. We tested these claims with new measurements using the software LEAFGUI in comparison with digital tracing using ImageJ software. We found that the apparent increase of VLA with magnification was an artifact of (1) using low-quality and low-magnification images and (2) errors in the algorithms of LEAFGUI. Given the use of images of sufficient magnification and quality, and analysis with error-free software, the VLA can be measured precisely and accurately. These findings point to important principles for improving the quantity and quality of important information gathered from leaf vein systems. © 2014 American Society of Plant Biologists. All Rights Reserved.
Montgomery, Brian L; Shivas, Martin A; Hall-Mendelin, Sonja; Edwards, Jim; Hamilton, Nicholas A; Jansen, Cassie C; McMahon, Jamie L; Warrilow, David; van den Hurk, Andrew F
2017-03-01
The globally important Zika, dengue and chikungunya viruses are primarily transmitted by the invasive mosquitoes, Aedes aegypti and Aedes albopictus. In Australia, there is an increasing risk that these species may invade highly urbanized regions and trigger outbreaks. We describe the development of a Rapid Surveillance for Vector Presence (RSVP) system to expedite presence- absence surveys for both species. We developed a methodology that uses molecular assays to efficiently screen pooled ovitrap (egg trap) samples for traces of target species ribosomal RNA. Firstly, specific real-time reverse transcription-polymerase chain reaction (RT-PCR) assays were developed which detect a single Ae. aegypti or Ae. albopictus first instar larva in samples containing 4,999 and 999 non-target mosquitoes, respectively. ImageJ software was evaluated as an automated egg counting tool using ovitrap collections obtained from Brisbane, Australia. Qualitative assessment of ovistrips was required prior to automation because ImageJ did not differentiate between Aedes eggs and other objects or contaminants on 44.5% of ovistrips assessed, thus compromising the accuracy of egg counts. As a proof of concept, the RSVP was evaluated in Brisbane, Rockhampton and Goomeri, locations where Ae. aegypti is considered absent, present, and at the margin of its range, respectively. In Brisbane, Ae. aegypti was not detected in 25 pools formed from 477 ovitraps, comprising ≈ 54,300 eggs. In Rockhampton, Ae. aegypti was detected in 4/6 pools derived from 45 ovitraps, comprising ≈ 1,700 eggs. In Goomeri, Ae. aegypti was detected in 5/8 pools derived from 62 ovitraps, comprising ≈ 4,200 eggs. RSVP can rapidly detect nucleic acids from low numbers of target species within large samples of endemic species aggregated from multiple ovitraps. This screening capability facilitates deployment of ovitrap configurations of varying spatial scales, from a single residential block to entire suburbs or towns. RSVP is a powerful tool for surveillance of invasive Aedes spp., validation of species eradication and quality assurance for vector control operations implemented during disease outbreaks.
Montgomery, Brian L.; Shivas, Martin A.; Hall-Mendelin, Sonja; Edwards, Jim; Hamilton, Nicholas A.; Jansen, Cassie C.; McMahon, Jamie L.; Warrilow, David
2017-01-01
Background The globally important Zika, dengue and chikungunya viruses are primarily transmitted by the invasive mosquitoes, Aedes aegypti and Aedes albopictus. In Australia, there is an increasing risk that these species may invade highly urbanized regions and trigger outbreaks. We describe the development of a Rapid Surveillance for Vector Presence (RSVP) system to expedite presence- absence surveys for both species. Methodology/Principal findings We developed a methodology that uses molecular assays to efficiently screen pooled ovitrap (egg trap) samples for traces of target species ribosomal RNA. Firstly, specific real-time reverse transcription-polymerase chain reaction (RT-PCR) assays were developed which detect a single Ae. aegypti or Ae. albopictus first instar larva in samples containing 4,999 and 999 non-target mosquitoes, respectively. ImageJ software was evaluated as an automated egg counting tool using ovitrap collections obtained from Brisbane, Australia. Qualitative assessment of ovistrips was required prior to automation because ImageJ did not differentiate between Aedes eggs and other objects or contaminants on 44.5% of ovistrips assessed, thus compromising the accuracy of egg counts. As a proof of concept, the RSVP was evaluated in Brisbane, Rockhampton and Goomeri, locations where Ae. aegypti is considered absent, present, and at the margin of its range, respectively. In Brisbane, Ae. aegypti was not detected in 25 pools formed from 477 ovitraps, comprising ≈ 54,300 eggs. In Rockhampton, Ae. aegypti was detected in 4/6 pools derived from 45 ovitraps, comprising ≈ 1,700 eggs. In Goomeri, Ae. aegypti was detected in 5/8 pools derived from 62 ovitraps, comprising ≈ 4,200 eggs. Conclusions/Significance RSVP can rapidly detect nucleic acids from low numbers of target species within large samples of endemic species aggregated from multiple ovitraps. This screening capability facilitates deployment of ovitrap configurations of varying spatial scales, from a single residential block to entire suburbs or towns. RSVP is a powerful tool for surveillance of invasive Aedes spp., validation of species eradication and quality assurance for vector control operations implemented during disease outbreaks. PMID:28339458
Correspondence between fiber post and drill dimensions for post canal preparation.
Portigliatti, Ricardo Pablo; Tumini, José Luis; Bertoldi Hepburn, Alejandro Daniel; Aromando, Romina Flavia; Olmos, Jorge Lorenzo
2017-12-01
To compare fiber posts of several calibers and trademarks to their corresponding root canal preparation drills. Three widely used endodontic post brands and their drills were evaluated: Exacto, ParaPost Taper Lux, and Macro-Lock Illusion X-RO. Fiber posts and drills were microphotographed with a scanning electron microscope and images were analyzed using ImageJ image processing software. Fiber post diameter on apical extreme (Pd0), fiber post diameter at 5 mm from the apical extreme (Pd5), drill diameter on apical extreme (Dd0) and drill diameter at 5 mm from the apical extreme (Dd5) were analyzed. The data were statistically analyzed using student t-test. Exacto posts 0.5 showed larger dimensions than their corresponding drills (P< 0.05) at Pd0. Macro-Lock posts showed no significant differences vs. their drills at Pd0 in any of the studied groups. ParaPost drills 4.5, 5 and 5.5 were statistically significantly larger than their posts at Dd0 (P< 0.05). Exacto posts 0.5 and 1 showed larger dimensions than their drills measured at Pd5 (P< 0.05). Exacto posts number 2 showed smaller calibers than their corresponding drills at Pd5 (P< 0.05). Macro-Lock drills number 4 and ParaPost drills number 5 were larger than their posts at Dd5 (P< 0.05). Poor spatial correspondence between post and drill dimensions can adversely affect the film thickness of the resin cement, diminishing bond strength due to polymerization shrinkage. The lack of correspondence in size between posts and drills may lead to the formation of empty chambers between the post and endodontic obturation with excessive luting cement thickness, thus inducing critical C-Factor stresses.
3D printing of preclinical X-ray computed tomographic data sets.
Doney, Evan; Krumdick, Lauren A; Diener, Justin M; Wathen, Connor A; Chapman, Sarah E; Stamile, Brian; Scott, Jeremiah E; Ravosa, Matthew J; Van Avermaete, Tony; Leevy, W Matthew
2013-03-22
Three-dimensional printing allows for the production of highly detailed objects through a process known as additive manufacturing. Traditional, mold-injection methods to create models or parts have several limitations, the most important of which is a difficulty in making highly complex products in a timely, cost-effective manner.(1) However, gradual improvements in three-dimensional printing technology have resulted in both high-end and economy instruments that are now available for the facile production of customized models.(2) These printers have the ability to extrude high-resolution objects with enough detail to accurately represent in vivo images generated from a preclinical X-ray CT scanner. With proper data collection, surface rendering, and stereolithographic editing, it is now possible and inexpensive to rapidly produce detailed skeletal and soft tissue structures from X-ray CT data. Even in the early stages of development, the anatomical models produced by three-dimensional printing appeal to both educators and researchers who can utilize the technology to improve visualization proficiency. (3, 4) The real benefits of this method result from the tangible experience a researcher can have with data that cannot be adequately conveyed through a computer screen. The translation of pre-clinical 3D data to a physical object that is an exact copy of the test subject is a powerful tool for visualization and communication, especially for relating imaging research to students, or those in other fields. Here, we provide a detailed method for printing plastic models of bone and organ structures derived from X-ray CT scans utilizing an Albira X-ray CT system in conjunction with PMOD, ImageJ, Meshlab, Netfabb, and ReplicatorG software packages.
Heterogeneity of shale documented by micro-FTIR and image analysis.
Chen, Yanyan; Mastalerz, Maria; Schimmelmann, Arndt
2014-12-01
In this study, four New Albany Shale Devonian and Mississippian samples, with vitrinite reflectance [Ro ] values ranging from 0.55% to 1.41%, were analyzed by micro-FTIR mapping of chemical and mineralogical properties. One additional postmature shale sample from the Haynesville Shale (Kimmeridgian, Ro = 3.0%) was included to test the limitation of the method for more mature substrates. Relative abundances of organic matter and mineral groups (carbonates, quartz and clays) were mapped across selected microscale regions based on characteristic infrared peaks and demonstrated to be consistent with corresponding bulk compositional percentages. Mapped distributions of organic matter provide information on the organic matter abundance and the connectivity of organic matter within the overall shale matrix. The pervasive distribution of organic matter mapped in the New Albany Shale sample MM4 is in agreement with this shale's high total organic carbon abundance relative to other samples. Mapped interconnectivity of organic matter domains in New Albany Shale samples is excellent in two early mature shale samples having Ro values from 0.55% to 0.65%, then dramatically decreases in a late mature sample having an intermediate Ro of 1.15% and finally increases again in the postmature sample, which has a Ro of 1.41%. Swanson permeabilities, derived from independent mercury intrusion capillary pressure porosimetry measurements, follow the same trend among the four New Albany Shale samples, suggesting that micro-FTIR, in combination with complementary porosimetric techniques, strengthens our understanding of porosity networks. In addition, image processing and analysis software (e.g. ImageJ) have the capability to quantify organic matter and total organic carbon - valuable parameters for highly mature rocks, because they cannot be analyzed by micro-FTIR owing to the weakness of the aliphatic carbon-hydrogen signal. © 2014 The Authors Journal of Microscopy © 2014 Royal Microscopical Society.
Examining the Spatial Frequency Components of a Digital Dental Detector
NASA Astrophysics Data System (ADS)
Anastasiou, A.; Michail, C.; Koukou, V.; Martini, N.; Bakas, A.; Papastamati, F.; Maragkaki, P.; Lavdas, L.; Fountos, G.; Valais, I.; Kalyvas, N.
2017-11-01
Digital X-ray detectors are widely used in dental radiography. The scope of this work is the examination of the spatial frequency component of a dedicated dental CMOS detector. A commercially available SCHICK CDR CMOS detector was irradiated at a Del Medical Eureka X-ray system at 60kVp and 70kVp. The irradiation setup included images of an edge, for Modulation Transfer Function (MTF) calculation. The air-KERMA was measured with an RTI PIRANHA X-ray multimeter. The images were evaluated in ‘for presentation’ format with the use of ImageJ software. The linear range of the detector was found in the range 13μGy-183μGy at 60 kVp and 18μGy-180μGy at 70 kVp. By inspecting the MTF curves it was found that MTF(6lp/mm)60kVp=0.29 and MTF(6lp/mm)70kVp=0.25. The inspection of the Normalized Noise Power Spetrum (NNPS) showed similar low noise components. Our results indicate that this detector presents comparable performance at both kVp, although its X-ray response (pixel value vs air KERMA) was not equal to previously published results, for the same detector type.
NASA Technical Reports Server (NTRS)
Udave, Ceasar
2017-01-01
Microgravity is one of the most import factors in space flight where its impact on living biological organisms is concerned. Many different ailments have been reported in astronauts such as spaceflight related osteopenia, cardiovascular concerns, and loss of eye sight. In order to understand why µg causes these issues we must understand what is happening at the most basic of biological structures, the cell. The work done in this report is a culmination of contributions made to a much larger project. The project seeks to understand how cellular physiology is changing in SMG conditions and use this knowledge to feed into a follow-up study on the genetic changes that are seen in SMG environments. Cells were imaged using confocal microscopy after 20hrs and 48hrs in a 3D clinostat called the Gravite. Lengths, widths, heights, and total cell areas were measured using an image analysis software package ImageJ. There were significant differences in lengths and widths of cell nuclei, and total area of cell coverage. The report then discusses some of the problems with the testing apparatus and how 3D printing technology may be used to create better sample holders for the 3D clinostat.
Point Analysis in Java applied to histological images of the perforant pathway: a user's account.
Scorcioni, Ruggero; Wright, Susan N; Patrick Card, J; Ascoli, Giorgio A; Barrionuevo, Germán
2008-01-01
The freeware Java tool Point Analysis in Java (PAJ), created to perform 3D point analysis, was tested in an independent laboratory setting. The input data consisted of images of the hippocampal perforant pathway from serial immunocytochemical localizations of the rat brain in multiple views at different resolutions. The low magnification set (x2 objective) comprised the entire perforant pathway, while the high magnification set (x100 objective) allowed the identification of individual fibers. A preliminary stereological study revealed a striking linear relationship between the fiber count at high magnification and the optical density at low magnification. PAJ enabled fast analysis for down-sampled data sets and a friendly interface with automated plot drawings. Noted strengths included the multi-platform support as well as the free availability of the source code, conducive to a broad user base and maximum flexibility for ad hoc requirements. PAJ has great potential to extend its usability by (a) improving its graphical user interface, (b) increasing its input size limit, (c) improving response time for large data sets, and (d) potentially being integrated with other Java graphical tools such as ImageJ.
Wang, Hai-yi; Su, Zi-hua; Xu, Xiao; Sun, Zhi-peng; Duan, Fei-xue; Song, Yuan-yuan; Li, Lu; Wang, Ying-wei; Ma, Xin; Guo, Ai-tao; Ma, Lin; Ye, Hui-yi
2016-01-01
Pharmacokinetic parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) have been increasingly used to evaluate the permeability of tumor vessel. Histogram metrics are a recognized promising method of quantitative MR imaging that has been recently introduced in analysis of DCE-MRI pharmacokinetic parameters in oncology due to tumor heterogeneity. In this study, 21 patients with renal cell carcinoma (RCC) underwent paired DCE-MRI studies on a 3.0 T MR system. Extended Tofts model and population-based arterial input function were used to calculate kinetic parameters of RCC tumors. Mean value and histogram metrics (Mode, Skewness and Kurtosis) of each pharmacokinetic parameter were generated automatically using ImageJ software. Intra- and inter-observer reproducibility and scan–rescan reproducibility were evaluated using intra-class correlation coefficients (ICCs) and coefficient of variation (CoV). Our results demonstrated that the histogram method (Mode, Skewness and Kurtosis) was not superior to the conventional Mean value method in reproducibility evaluation on DCE-MRI pharmacokinetic parameters (K trans & Ve) in renal cell carcinoma, especially for Skewness and Kurtosis which showed lower intra-, inter-observer and scan-rescan reproducibility than Mean value. Our findings suggest that additional studies are necessary before wide incorporation of histogram metrics in quantitative analysis of DCE-MRI pharmacokinetic parameters. PMID:27380733
MO-G-BRF-07: Anomalously Fast Diffusion of Carbon Nanotubes Carriers in 3D Tissue Model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Y; Bahng, J; Kotov, N
Purpose: We aim to investigate and understand diffusion process of carbon nanotubes (CNTs) and other nanoscale particles in tissue and organs. Methods: In this research, we utilized a 3D model tissue of hepatocellular carcinoma (HCC)cultured in inverted colloidal crystal (ICC) scaffolds to compare the diffusivity of CNTs with small molecules such as Rhodamine and FITC in vitro, and further investigated the transportation of CNTs with and without targeting ligand, TGFβ1. The real-time permeation profiles of CNTs in HCC tissue model with high temporal and spatial resolution was demonstrated by using standard confocal microscopy. Quantitative analysis of the diffusion process inmore » 3D was carried out using luminescence intensity in a series of Z-stack images obtained for different time points of the diffusion process after initial addition of CNTs or small molecules to the cell culture and the image data was analyzed by software ImageJ and Mathematica. Results: CNTs display diffusion rate in model tissues substantially faster than small molecules of the similar charge such as FITC, and the diffusion rate of CNTs are significantly enhanced with targeting ligand, TGFβ1. Conclusion: In terms of the advantages of in-vitro model, we were able to have access to measuring the rate of CNT penetration at designed conditions with variable parameters. And the findings by using this model, changed our understanding about advantages of CNTs as nanoscale drug carriers and provides design principles for making new drug carriers for both treatment and diagnostics. Additionally the fast diffusion opens the discussion of the best possible drug carriers to reach deep parts of cancerous tissues, which is often a prerequisite for successful cancer treatment. This work was supported by the Center for Photonic and Multiscale Nanomaterials funded by National Science Foundation Materials Research Science and Engineering Center program DMR 1120923. The work was also partially supported by NSF grant ECS-0601345; EFRI-BSBA 0938019; CBET 0933384; CBET 0932823; CBET 1036672, AFOSR MURI 444286-P061716 and NIH 1R21CA121841-01A2.« less
Particle Shape Characterization of Lunar Regolith using Reflected Light Microscopy
NASA Astrophysics Data System (ADS)
McCarty, C. B.; Garcia, G. C.; Rickman, D.
2014-12-01
Automated identification of particles in lunar thin sections is necessary for practical measurement of particle shape, void characterization, and quantitative characterization of sediment fabric. This may be done using image analysis, but several aspects of the lunar regolith make such automations difficult. For example, many of the particles are shattered; others are aggregates of smaller particles. Sieve sizes of the particles span 5 orders of magnitude. The physical thickness of a thin section, at a nominal 30 microns, is large compared to the size of many of the particles. Image acquisition modes, such as SEM and reflected light, while superior to transmitted light, still have significant ambiguity as to the volume being sampled. It is also desirable to have a technique that is inexpensive, not resource intensive, and analytically robust. To this end, we have developed an image acquisition and processing protocol that identifies and delineates resolvable particles on the front surface of a lunar thin section using a petrographic microscope in reflected light. For a polished thin section, a grid is defined covering the entire thin section. The grid defines discrete images taken with 20% overlap, minimizing the number of particles that intersect image boundaries. In reflected light mode, two images are acquired at each grid location, with a closed aperture diaphragm. One image, A, is focused precisely on the front surface of the thin section. The second image, B, is made after the stage is brought toward the objective lens just slightly. A bright fringe line, analogous to a Becke line, appears inside all transparent particles at the front surface of the section in the second image. The added light in the bright line corresponds to a deficit around the particles. Particle identification is done using ImageJ and uses multiple steps. A hybrid 5x5 median filter is used to make images Af and Bf. This primarily removes very small particles just below the front surface of the section. Bf - (Bf/Af) is then computed. The division strongly enhances the fringe and the deficit, while minimizing the correlated information in A and B. The subtraction emphasizes the particle-epoxy boundaries. The resulting image is converted to binary, and then holes are filled. Cracks are removed using a median-based operator.
Metal artefact reduction with cone beam CT: an in vitro study
Bechara, BB; Moore, WS; McMahan, CA; Noujeim, M
2012-01-01
Background Metal in a patient's mouth has been shown to cause artefacts that can interfere with the diagnostic quality of cone beam CT. Recently, a manufacturer has made an algorithm and software available which reduces metal streak artefact (Picasso Master 3D® machine; Vatech, Hwaseong, Republic of Korea). Objectives The purpose of this investigation was to determine whether or not the metal artefact reduction algorithm was effective and enhanced the contrast-to-noise ratio. Methods A phantom was constructed incorporating three metallic beads and three epoxy resin-based bone substitutes to simulate bone next to metal. The phantom was placed in the centre of the field of view and at the periphery. 10 data sets were acquired at 50–90 kVp. The images obtained were analysed using a public domain software ImageJ (NIH Image, Bethesda, MD). Profile lines were used to evaluate grey level changes and area histograms were used to evaluate contrast. The contrast-to-noise ratio was calculated. Results The metal artefact reduction option reduced grey value variation and increased the contrast-to-noise ratio. The grey value varied least when the phantom was in the middle of the volume and the metal artefact reduction was activated. The image quality improved as the peak kilovoltage increased. Conclusion Better images of a phantom were obtained when the metal artefact reduction algorithm was used. PMID:22241878
Kang, Shin J.; Zhang, Qing; Patel, Samirkumar R.; Berezovsky, Damian; Yang, Hua; Wang, Yanggan; Grossniklaus, Hans E.
2013-01-01
Purpose To evaluate the utility of in vivo imaging of rabbit model of choroidal melanoma utilizing high-frequency contrast-enhanced ultrasound (HF-CE-US) with 2-or 3-dimensional modes, and to correlate the sonographic findings with histopathologic characteristics. Methods Five New Zealand white rabbits which were immunosuppressed with daily cyclosporin A were inoculated into their right eyes with aliquots of 1.5×106 / 50 µL of 92.1 human uveal melanoma cells cultured in RPMI. At week 4, the tumor-bearing eyes were imaged using high-frequency ultrasound with microbubble contrast agent to determine the 2-dimensional tumor size and relative blood volume and by 3-dimensional mode to determine tumor volume. Histologic tumor burden was quantified in enucleated eyes by ImageJ software, and microvascular density (MVD) was determined by counting vascular channels in PAS without hematoxylin sections. Results Utilizing HF-CE-US, melanomas were visualized as relatively hyperechoic regions in the images. The correlation coefficients of sonographic size or volume compared with histologic area were 0.72 and 0.70, respectively. The sonographic tumor relative blood volume correlated with the histologic tumor vascularity (R2=0.92, P=0.04) Conclusions There is a positive correlation between in vivo sonographic tumor volume/size and histologic tumor size in our rabbit choroidal melanoma model. HF-CE-US corresponds to microvascular density and blood volume. PMID:23645822
Cordelières, Fabrice P; Petit, Valérie; Kumasaka, Mayuko; Debeir, Olivier; Letort, Véronique; Gallagher, Stuart J; Larue, Lionel
2013-01-01
Cell migration is a key biological process with a role in both physiological and pathological conditions. Locomotion of cells during embryonic development is essential for their correct positioning in the organism; immune cells have to migrate and circulate in response to injury. Failure of cells to migrate or an inappropriate acquisition of migratory capacities can result in severe defects such as altered pigmentation, skull and limb abnormalities during development, and defective wound repair, immunosuppression or tumor dissemination. The ability to accurately analyze and quantify cell migration is important for our understanding of development, homeostasis and disease. In vitro cell tracking experiments, using primary or established cell cultures, are often used to study migration as cells can quickly and easily be genetically or chemically manipulated. Images of the cells are acquired at regular time intervals over several hours using microscopes equipped with CCD camera. The locations (x,y,t) of each cell on the recorded sequence of frames then need to be tracked. Manual computer-assisted tracking is the traditional method for analyzing the migratory behavior of cells. However, this processing is extremely tedious and time-consuming. Most existing tracking algorithms require experience in programming languages that are unfamiliar to most biologists. We therefore developed an automated cell tracking program, written in Java, which uses a mean-shift algorithm and ImageJ as a library. iTrack4U is a user-friendly software. Compared to manual tracking, it saves considerable amount of time to generate and analyze the variables characterizing cell migration, since they are automatically computed with iTrack4U. Another major interest of iTrack4U is the standardization and the lack of inter-experimenter differences. Finally, iTrack4U is adapted for phase contrast and fluorescent cells.
NASA Astrophysics Data System (ADS)
Rasmussen, John C.; Bautista, Merrick; Tan, I.-Chih; Adams, Kristen E.; Aldrich, Melissa; Marshall, Milton V.; Fife, Caroline E.; Maus, Erik A.; Smith, Latisha A.; Zhang, Jingdan; Xiang, Xiaoyan; Zhou, Shaohua Kevin; Sevick-Muraca, Eva M.
2011-02-01
Recently, we demonstrated near-infrared (NIR) fluorescence imaging for quantifying real-time lymphatic propulsion in humans following intradermal injections of microdose amounts of indocyanine green. However computational methods for image analysis are underdeveloped, hindering the translation and clinical adaptation of NIR fluorescent lymphatic imaging. In our initial work we used ImageJ and custom MatLab programs to manually identify lymphatic vessels and individual propulsion events using the temporal transit of the fluorescent dye. In addition, we extracted the apparent velocities of contractile propagation and time periods between propulsion events. Extensive time and effort were required to analyze the 6-8 gigabytes of NIR fluorescent images obtained for each subject. To alleviate this bottleneck, we commenced development of ALFIA, an integrated software platform which will permit automated, near real-time analysis of lymphatic function using NIR fluorescent imaging. However, prior to automation, the base algorithms calculating the apparent velocity and period must be validated to verify that they produce results consistent with the proof-of-concept programs. To do this, both methods were used to analyze NIR fluorescent images of two subjects and the number of propulsive events identified, the average apparent velocities, and the average periods for each subject were compared. Paired Student's t-tests indicate that the differences between their average results are not significant. With the base algorithms validated, further development and automation of ALFIA can be realized, significantly reducing the amount of user interaction required, and potentially enabling the near real-time, clinical evaluation of NIR fluorescent lymphatic imaging.
Optical Density Analysis of X-Rays Utilizing Calibration Tooling to Estimate Thickness of Parts
NASA Technical Reports Server (NTRS)
Grau, David
2012-01-01
This process is designed to estimate the thickness change of a material through data analysis of a digitized version of an x-ray (or a digital x-ray) containing the material (with the thickness in question) and various tooling. Using this process, it is possible to estimate a material's thickness change in a region of the material or part that is thinner than the rest of the reference thickness. However, that same principle process can be used to determine the thickness change of material using a thinner region to determine thickening, or it can be used to develop contour plots of an entire part. Proper tooling must be used. An x-ray film with an S-shaped characteristic curve or a digital x-ray device with a product resulting in like characteristics is necessary. If a film exists with linear characteristics, this type of film would be ideal; however, at the time of this reporting, no such film has been known. Machined components (with known fractional thicknesses) of a like material (similar density) to that of the material to be measured are necessary. The machined components should have machined through-holes. For ease of use and better accuracy, the throughholes should be a size larger than 0.125 in. (.3 mm). Standard components for this use are known as penetrameters or image quality indicators. Also needed is standard x-ray equipment, if film is used in place of digital equipment, or x-ray digitization equipment with proven conversion properties. Typical x-ray digitization equipment is commonly used in the medical industry, and creates digital images of x-rays in DICOM format. It is recommended to scan the image in a 16-bit format. However, 12-bit and 8-bit resolutions are acceptable. Finally, x-ray analysis software that allows accurate digital image density calculations, such as Image-J freeware, is needed. The actual procedure requires the test article to be placed on the raw x-ray, ensuring the region of interest is aligned for perpendicular x-ray exposure capture. One or multiple machined components of like material/ density with known thicknesses are placed atop the part (preferably in a region of nominal and non-varying thickness) such that exposure of the combined part and machined component lay-up is captured on the x-ray. Depending on the accuracy required, the machined component fs thickness must be carefully chosen. Similarly, depending on the accuracy required, the lay-up must be exposed such that the regions of the x-ray to be analyzed have a density range between 1 and 4.5. After the exposure, the image is digitized, and the digital image can then be analyzed using the image analysis software.
AlQahtani, Nabeeh A; Haralur, Satheesh B; AlMaqbol, Mohammad; AlMufarrij, Ali Jubran; Al Dera, Ahmed Ali; Al-Qarni, Mohammed
2016-04-01
To determine the occurrence of smile line and maxillary tooth shape in the Saudi Arabian subpopulation, and to estimate the association between these parameters with gingival biotype. On the fulfillment of selection criteria, total 315 patients belong to Saudi Arabian ethnic group were randomly selected. Two frontal photographs of the patients were acquired. The tooth morphology, gingival angle, and smile line classification were determined with ImageJ image analyzing software. The gingival biotype was assessed by probe transparency method. The obtained data were analyzed with SPSS 19 (IBM Corporation, New York, USA) software to determine the frequency and association between other parameters and gingival biotype. Among the clinical parameters evaluated, the tapering tooth morphology (56.8%), thick gingival biotype (53%), and average smile line (57.5%) was more prevalent. The statistically significant association was found between thick gingival biotype and the square tooth, high smile line. The high gingival angle was associated with thin gingival biotype. The study results indicate the existence of an association between tooth shape, smile line, and gingival angle with gingival biotype.
Characterization and correction of cupping effect artefacts in cone beam CT
Hunter, AK; McDavid, WD
2012-01-01
Objective The purpose of this study was to demonstrate and correct the cupping effect artefact that occurs owing to the presence of beam hardening and scatter radiation during image acquisition in cone beam CT (CBCT). Methods A uniform aluminium cylinder (6061) was used to demonstrate the cupping effect artefact on the Planmeca Promax 3D CBCT unit (Planmeca OY, Helsinki, Finland). The cupping effect was studied using a line profile plot of the grey level values using ImageJ software (National Institutes of Health, Bethesda, MD). A hardware-based correction method using copper pre-filtration was used to address this artefact caused by beam hardening and a software-based subtraction algorithm was used to address scatter contamination. Results The hardware-based correction used to address the effects of beam hardening suppressed the cupping effect artefact but did not eliminate it. The software-based correction used to address the effects of scatter resulted in elimination of the cupping effect artefact. Conclusion Compensating for the presence of beam hardening and scatter radiation improves grey level uniformity in CBCT. PMID:22378754
Yazar, Memet; Sevim, Kamuran Zeynep; Irmak, Fatih; Yazar, Sevgi Kurt; Yeşilada, Ayşin Karasoy; Karşidağğ, Semra Hacikerim; Tatlidede, Hamit Soner
2013-07-01
Ear reconstruction is one of the most challenging procedures in plastic surgery practice. Many studies and techniques have been described in the literature for carving a well-pronounced framework. However, just as important as the cartilage framework is the ample amount of delicate skin coverage of the framework. In this report, we introduce an innovative method of measuring the skin surface area of the auricle from a three-dimensional template created from the healthy ear.The study group consisted of 60 adult Turkish individuals who were randomly selected (30 men and 30 women). The participant ages ranged from 18 to 45 years (mean, 31.5 years), and they had no history of trauma or congenital anomalies. The template is created by dividing the ear into aesthetic subunits and using ImageJ software to estimate the necessary amount of total skin surface area required.Reconstruction of the auricle is a complicated process that requires experience and patience to provide the auricular details. We believe this estimate will shorten the learning curve for residents and surgeons interested in ear reconstruction and will help surgeons obtain adequate skin to drape over the well-sculpted cartilage frameworks by providing a reference list of total ear skin surface area measurements for Turkish men and women.
A simple automated system for appetitive conditioning of zebrafish in their home tanks.
Doyle, Jillian M; Merovitch, Neil; Wyeth, Russell C; Stoyek, Matthew R; Schmidt, Michael; Wilfart, Florentin; Fine, Alan; Croll, Roger P
2017-01-15
We describe here an automated apparatus that permits rapid conditioning paradigms for zebrafish. Arduino microprocessors were used to control the delivery of auditory or visual stimuli to groups of adult or juvenile zebrafish in their home tanks in a conventional zebrafish facility. An automatic feeder dispensed precise amounts of food immediately after the conditioned stimuli, or at variable delays for controls. Responses were recorded using inexpensive cameras, with the video sequences analysed with ImageJ or Matlab. Fish showed significant conditioned responses in as few as 5 trials, learning that the conditioned stimulus was a predictor of food presentation at the water surface and at the end of the tank where the food was dispensed. Memories of these conditioned associations persisted for at least 2days after training when fish were tested either as groups or as individuals. Control fish, for which the auditory or visual stimuli were specifically unpaired with food, showed no comparable responses. This simple, low-cost, automated system permits scalable conditioning of zebrafish with minimal human intervention, greatly reducing both variability and labour-intensiveness. It will be useful for studies of the neural basis of learning and memory, and for high-throughput screening of compounds modifying those processes. Copyright © 2016 Elsevier B.V. All rights reserved.
Radiochromic film calibration for the RQT9 quality beam
NASA Astrophysics Data System (ADS)
Costa, K. C.; Gomez, A. M. L.; Alonso, T. C.; Mourao, A. P.
2017-11-01
When ionizing radiation interacts with matter it generates energy deposition. Radiation dosimetry is important for medical applications of ionizing radiation due to the increasing demand for diagnostic radiology and radiotherapy. Different dosimetry methods are used and each one has its advantages and disadvantages. The film is a dose measurement method that records the energy deposition by the darkening of its emulsion. Radiochromic films have a little visible light sensitivity and respond better to ionizing radiation exposure. The aim of this study is to obtain the resulting calibration curve by the irradiation of radiochromic film strips, making it possible to relate the darkening of the film with the absorbed dose, in order to measure doses in experiments with X-ray beam of 120 kV, in computed tomography (CT). Film strips of GAFCHROMIC XR-QA2 were exposed according to RQT9 reference radiation, which defines an X-ray beam generated from a voltage of 120 kV. Strips were irradiated in "Laboratório de Calibração de Dosímetros do Centro de Desenvolvimento da Tecnologia Nuclear" (LCD / CDTN) at a dose range of 5-30 mGy, corresponding to the range values commonly used in CT scans. Digital images of the irradiated films were analyzed by using the ImageJ software. The darkening responses on film strips according to the doses were observed and they allowed obtaining the corresponding numeric values to the darkening for each specific dose value. From the numerical values of darkening, a calibration curve was obtained, which correlates the darkening of the film strip with dose values in mGy. The calibration curve equation is a simplified method for obtaining absorbed dose values using digital images of radiochromic films irradiated. With the calibration curve, radiochromic films may be applied on dosimetry in experiments on CT scans using X-ray beam of 120 kV, in order to improve CT acquisition image processes.
Hasturk, Hatice; Nguyen, Daniel Huy; Sherzai, Homa; Song, Xiaoping; Soukos, Nikos; Bidlack, Felicitas B; Van Dyke, Thomas E
2013-08-01
The purpose of this study was to compare the impact of the removal of biofilm with hand scalers of different material composition on the surface of implant abutments by assessing the surface topography and residual plaque after scaling using scanning electron microscopy (SEM). Titanium implant analogs from 3 manufacturers (Straumann USA LLC, Andover, Maine, Nobel BioCare USA LLC, Yorba Linda, Cali, Astra Tech Implant Systems, Dentsply, Mölndal, Sweden) were mounted in stone in plastic vials individually with authentic prosthetic abutments. Plaque samples were collected from a healthy volunteer, inoculated into growth medium and incubated with the abutments anaerobically for 1 week. A blinded, calibrated hygienist performed scaling to remove the biofilm using 6 implant scalers (in triplicate), 1 scaler for 1 abutment. The abutments were mounted on an imaging stand and processed for SEM. Images were captured in 3 randomly designated areas of interest on each abutment. Analysis of the implant polished abutment surface and plaque area measurements were performed using ImageJ image analysis software. Surface alterations were characterized by the number, length, depth and the width of the scratches observed. Glass filled resin scalers resulted in significantly more and longer scratches on all 3 abutment types compared to other scalers, while unfilled resin scalers resulted in the least surface change (p < 0.05). Filled resin-graphite reinforced scalers, carbon fiber reinforced resin scalers and titanium scalers resulted in more superficial scratches compared to glass filled resin, as well as more scratches than unfilled resin. No statistically significant differences were found between scalers and abutments with regard to plaque removal. The impact of scalers on implant abutment surfaces varies between abutment types presumably due to different surface characteristics with no apparent advantage of one abutment type over the other with regard to resistance to surface damage. Unfilled resin was found consistently to be the least damaging to abutment surfaces, although all scalers of all compositions caused detectable surface changes to polished surfaces of implant abutments.
Chalfoun, J; Majurski, M; Peskin, A; Breen, C; Bajcsy, P; Brady, M
2015-10-01
New microscopy technologies are enabling image acquisition of terabyte-sized data sets consisting of hundreds of thousands of images. In order to retrieve and analyze the biological information in these large data sets, segmentation is needed to detect the regions containing cells or cell colonies. Our work with hundreds of large images (each 21,000×21,000 pixels) requires a segmentation method that: (1) yields high segmentation accuracy, (2) is applicable to multiple cell lines with various densities of cells and cell colonies, and several imaging modalities, (3) can process large data sets in a timely manner, (4) has a low memory footprint and (5) has a small number of user-set parameters that do not require adjustment during the segmentation of large image sets. None of the currently available segmentation methods meet all these requirements. Segmentation based on image gradient thresholding is fast and has a low memory footprint. However, existing techniques that automate the selection of the gradient image threshold do not work across image modalities, multiple cell lines, and a wide range of foreground/background densities (requirement 2) and all failed the requirement for robust parameters that do not require re-adjustment with time (requirement 5). We present a novel and empirically derived image gradient threshold selection method for separating foreground and background pixels in an image that meets all the requirements listed above. We quantify the difference between our approach and existing ones in terms of accuracy, execution speed, memory usage and number of adjustable parameters on a reference data set. This reference data set consists of 501 validation images with manually determined segmentations and image sizes ranging from 0.36 Megapixels to 850 Megapixels. It includes four different cell lines and two image modalities: phase contrast and fluorescent. Our new technique, called Empirical Gradient Threshold (EGT), is derived from this reference data set with a 10-fold cross-validation method. EGT segments cells or colonies with resulting Dice accuracy index measurements above 0.92 for all cross-validation data sets. EGT results has also been visually verified on a much larger data set that includes bright field and Differential Interference Contrast (DIC) images, 16 cell lines and 61 time-sequence data sets, for a total of 17,479 images. This method is implemented as an open-source plugin to ImageJ as well as a standalone executable that can be downloaded from the following link: https://isg.nist.gov/. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.
Characterisation of human non-proliferative diabetic retinopathy using the fractal analysis
Ţălu, Ştefan; Călugăru, Dan Mihai; Lupaşcu, Carmen Alina
2015-01-01
AIM To investigate and quantify changes in the branching patterns of the retina vascular network in diabetes using the fractal analysis method. METHODS This was a clinic-based prospective study of 172 participants managed at the Ophthalmological Clinic of Cluj-Napoca, Romania, between January 2012 and December 2013. A set of 172 segmented and skeletonized human retinal images, corresponding to both normal (24 images) and pathological (148 images) states of the retina were examined. An automatic unsupervised method for retinal vessel segmentation was applied before fractal analysis. The fractal analyses of the retinal digital images were performed using the fractal analysis software ImageJ. Statistical analyses were performed for these groups using Microsoft Office Excel 2003 and GraphPad InStat software. RESULTS It was found that subtle changes in the vascular network geometry of the human retina are influenced by diabetic retinopathy (DR) and can be estimated using the fractal geometry. The average of fractal dimensions D for the normal images (segmented and skeletonized versions) is slightly lower than the corresponding values of mild non-proliferative DR (NPDR) images (segmented and skeletonized versions). The average of fractal dimensions D for the normal images (segmented and skeletonized versions) is higher than the corresponding values of moderate NPDR images (segmented and skeletonized versions). The lowest values were found for the corresponding values of severe NPDR images (segmented and skeletonized versions). CONCLUSION The fractal analysis of fundus photographs may be used for a more complete undeTrstanding of the early and basic pathophysiological mechanisms of diabetes. The architecture of the retinal microvasculature in diabetes can be quantitative quantified by means of the fractal dimension. Microvascular abnormalities on retinal imaging may elucidate early mechanistic pathways for microvascular complications and distinguish patients with DR from healthy individuals. PMID:26309878
Characterisation of human non-proliferative diabetic retinopathy using the fractal analysis.
Ţălu, Ştefan; Călugăru, Dan Mihai; Lupaşcu, Carmen Alina
2015-01-01
To investigate and quantify changes in the branching patterns of the retina vascular network in diabetes using the fractal analysis method. This was a clinic-based prospective study of 172 participants managed at the Ophthalmological Clinic of Cluj-Napoca, Romania, between January 2012 and December 2013. A set of 172 segmented and skeletonized human retinal images, corresponding to both normal (24 images) and pathological (148 images) states of the retina were examined. An automatic unsupervised method for retinal vessel segmentation was applied before fractal analysis. The fractal analyses of the retinal digital images were performed using the fractal analysis software ImageJ. Statistical analyses were performed for these groups using Microsoft Office Excel 2003 and GraphPad InStat software. It was found that subtle changes in the vascular network geometry of the human retina are influenced by diabetic retinopathy (DR) and can be estimated using the fractal geometry. The average of fractal dimensions D for the normal images (segmented and skeletonized versions) is slightly lower than the corresponding values of mild non-proliferative DR (NPDR) images (segmented and skeletonized versions). The average of fractal dimensions D for the normal images (segmented and skeletonized versions) is higher than the corresponding values of moderate NPDR images (segmented and skeletonized versions). The lowest values were found for the corresponding values of severe NPDR images (segmented and skeletonized versions). The fractal analysis of fundus photographs may be used for a more complete undeTrstanding of the early and basic pathophysiological mechanisms of diabetes. The architecture of the retinal microvasculature in diabetes can be quantitative quantified by means of the fractal dimension. Microvascular abnormalities on retinal imaging may elucidate early mechanistic pathways for microvascular complications and distinguish patients with DR from healthy individuals.
SU-E-J-36: Comparison of CBCT Image Quality for Manufacturer Default Imaging Modes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelson, G
Purpose CBCT is being increasingly used in patient setup for radiotherapy. Often the manufacturer default scan modes are used for performing these CBCT scans with the assumption that they are the best options. To quantitatively assess the image quality of these scan modes, all of the scan modes were tested as well as options with the reconstruction algorithm. Methods A CatPhan 504 phantom was scanned on a TrueBeam Linear Accelerator using the manufacturer scan modes (FSRT Head, Head, Image Gently, Pelvis, Pelvis Obese, Spotlight, & Thorax). The Head mode scan was then reconstructed multiple times with all filter options (Smooth,more » Standard, Sharp, & Ultra Sharp) and all Ring Suppression options (Disabled, Weak, Medium, & Strong). An open source ImageJ tool was created for analyzing the CatPhan 504 images. Results The MTF curve was primarily dictated by the voxel size and the filter used in the reconstruction algorithm. The filters also impact the image noise. The CNR was worst for the Image Gently mode, followed by FSRT Head and Head. The sharper the filter, the worse the CNR. HU varied significantly between scan modes. Pelvis Obese had lower than expected HU values than most while the Image Gently mode had higher than expected HU values. If a therapist tried to use preset window and level settings, they would not show the desired tissue for some scan modes. Conclusion Knowing the image quality of the set scan modes, will enable users to better optimize their setup CBCT. Evaluation of the scan mode image quality could improve setup efficiency and lead to better treatment outcomes.« less
Generating patient-specific pulmonary vascular models for surgical planning
NASA Astrophysics Data System (ADS)
Murff, Daniel; Co-Vu, Jennifer; O'Dell, Walter G.
2015-03-01
Each year in the U.S., 7.4 million surgical procedures involving the major vessels are performed. Many of our patients require multiple surgeries, and many of the procedures include "surgical exploration". Procedures of this kind come with a significant amount of risk, carrying up to a 17.4% predicted mortality rate. This is especially concerning for our target population of pediatric patients with congenital abnormalities of the heart and major pulmonary vessels. This paper offers a novel approach to surgical planning which includes studying virtual and physical models of pulmonary vasculature of an individual patient before operation obtained from conventional 3D X-ray computed tomography (CT) scans of the chest. These models would provide clinicians with a non-invasive, intricately detailed representation of patient anatomy, and could reduce the need for invasive planning procedures such as exploratory surgery. Researchers involved in the AirPROM project have already demonstrated the utility of virtual and physical models in treatment planning of the airways of the chest. Clinicians have acknowledged the potential benefit from such a technology. A method for creating patient-derived physical models is demonstrated on pulmonary vasculature extracted from a CT scan with contrast of an adult human. Using a modified version of the NIH ImageJ program, a series of image processing functions are used to extract and mathematically reconstruct the vasculature tree structures of interest. An auto-generated STL file is sent to a 3D printer to create a physical model of the major pulmonary vasculature generated from 3D CT scans of patients.
Suassuna, Fernanda Clotilde Mariz; Maia, Ana Marly Araújo; Melo, Daniela Pita; Antonino, Antônio Celso Dantas; Gomes, Anderson Stevens Leônidas; Bento, Patrícia Meira
2018-02-01
To comparein vitro differences in the apical filling regarding working length (WL) change and presence of voids and to validate optical coherence tomography (OCT) in comparison with computerized microtomography (µCT) for the detection of failures in the apical filling. Forty-five uniradicular teeth with round canals, divided into groups (n = 15) following the obturation protocols: LC (lateral condensation), TMC (thermomechanical compaction) and SC (single cone). Samples were scanned using µCT (parameters: 80 kV, 222 µA, and resolution of 11 µm), OCT (parameters: SSOCT, 1300 nm and axial resolution of 12 µm), and periapical digital radiography. The images were analyzsed by two blind and calibrated observers using ImageJ software to measure the boundary of the obturation WL and voids presence. Categorical and metric data were submitted to inferential analysis, and the validity of the OCT as a diagnostic test was assessed with performance and reliability tests. The WL average remained constant for all obturation techniques and image methods. OCT showed adequate sensitivity and specificity to detect voids in the WL of apical obturations in vitro in comparison with µCT. Both image methods found a higher number of voids for LC technique (µCT p = 0.011/OCT p = 0.002). OCT can be used in apical obturation voids assessment and the LC technique revealed more voids with larger dimensions.
Optimisation approaches for concurrent transmitted light imaging during confocal microscopy.
Collings, David A
2015-01-01
The transmitted light detectors present on most modern confocal microscopes are an under-utilised tool for the live imaging of plant cells. As the light forming the image in this detector is not passed through a pinhole, out-of-focus light is not removed. It is this extended focus that allows the transmitted light image to provide cellular and organismal context for fluorescence optical sections generated confocally. More importantly, the transmitted light detector provides images that have spatial and temporal registration with the fluorescence images, unlike images taken with a separately-mounted camera. Because plants often provide difficulties for taking transmitted light images, with the presence of pigments and air pockets in leaves, this study documents several approaches to improving transmitted light images beginning with ensuring that the light paths through the microscope are correctly aligned (Köhler illumination). Pigmented samples can be imaged in real colour using sequential scanning with red, green and blue lasers. The resulting transmitted light images can be optimised and merged in ImageJ to generate colour images that maintain registration with concurrent fluorescence images. For faster imaging of pigmented samples, transmitted light images can be formed with non-absorbed wavelengths. Transmitted light images of Arabidopsis leaves expressing GFP can be improved by concurrent illumination with green and blue light. If the blue light used for YFP excitation is blocked from the transmitted light detector with a cheap, coloured glass filters, the non-absorbed green light will form an improved transmitted light image. Changes in sample colour can be quantified by transmitted light imaging. This has been documented in red onion epidermal cells where changes in vacuolar pH triggered by the weak base methylamine result in measurable colour changes in the vacuolar anthocyanin. Many plant cells contain visible levels of pigment. The transmitted light detector provides a useful tool for documenting and measuring changes in these pigments while maintaining registration with confocal imaging.
NASA Astrophysics Data System (ADS)
Ho, Wen-Jeng; Li, Guan-Yi; Liu, Jheng-Jie; Lin, Zong-Xian; You, Bang-Jin; Ho, Chun-Hung
2018-04-01
This study employed a two-step multi-cycle spin-coating method for the application of MAPbBr3 perovskite nanophosphors on textured silicon solar cells with the aim of enhancing photovoltaic performance through luminescent down-shifting (LDS). The surface morphology and dimensions of the MAPbBr3 perovskite nanophosphors were examined using scanning electron microscopy in conjunction with ImageJ software. The LDS effects of the nanophosphors were revealed by measuring photo-luminance, optical reflectance, and external quantum efficiency. The photovoltaic performance of cells with and without MAPbBr3 perovskite nanophosphors was evaluated according to photovoltaic current density-voltage (J-V) under AM 1.5 G solar illumination. Compared to uncoated cells, two-layer and one-layer coatings of MAPbBr3 perovskite nanophosphors were shown to enhance conversion efficiency by 4.56% and 3.38%, respectively.
A precise goniometer/tensiometer using a low cost single-board computer
NASA Astrophysics Data System (ADS)
Favier, Benoit; Chamakos, Nikolaos T.; Papathanasiou, Athanasios G.
2017-12-01
Measuring the surface tension and the Young contact angle of a droplet is extremely important for many industrial applications. Here, considering the booming interest for small and cheap but precise experimental instruments, we have constructed a low-cost contact angle goniometer/tensiometer, based on a single-board computer (Raspberry Pi). The device runs an axisymmetric drop shape analysis (ADSA) algorithm written in Python. The code, here named DropToolKit, was developed in-house. We initially present the mathematical framework of our algorithm and then we validate our software tool against other well-established ADSA packages, including the commercial ramé-hart DROPimage Advanced as well as the DropAnalysis plugin in ImageJ. After successfully testing for various combinations of liquids and solid surfaces, we concluded that our prototype device would be highly beneficial for industrial applications as well as for scientific research in wetting phenomena compared to the commercial solutions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suchitra, S. M., E-mail: suchitra.ph14f03@nitk.edu.in; Reddy, P. Ramana; Udayashankar, N. K.
2016-05-06
Porous anodic alumina (PAA) has been extensively studied in recent years due to their unique properties and applications for manufacturing nanostructured materials. In this article, we report our studies on structural and wetting properties of PAA membranes prepared using different electrolytes such as sulphuric, oxalic and phosphoric acids. The morphological parameters such as pore diameter and porosity were measured using SEM and analysed using image-J software. The structural investigation of PAA membranes was carried out through X-ray diffraction analysis and it was confirmed that PAA membranes were amorphous in nature. The wetting behaviour of PAA membranes were measured using contactmore » angle measurement technique. The results show that PAA membranes were hydrophilic in nature with contact angles 26.03°, 35.21° and 42.0° for sulphuric, oxalic and phosphoric acids respectively.« less
Synthesis of ZnO Hexagonal Micro Discs on Glass Substrates Using the Spray Pyrolysis Technique
NASA Astrophysics Data System (ADS)
Ikhmayies, Shadia J.; Zbib, Mohamad B.
2017-07-01
Zinc oxide (ZnO) is an important transparent conducting oxide of potential use in solar cells, electronics, photoelectronics, and sensors. In this work ZnO micro discs were synthesized in thin film form on glass substrates using the low cost spray pyrolysis method. The films were prepared from a precursor solution of ZnCl2 in distilled water at a substrate temperature of 300 ± 5°C. The as-synthesized samples were analyzed with x-ray diffraction, scanning electron microscopy, and x-ray energy dispersive spectroscopy (EDS). The morphology of the films showed randomly distributed micro discs of hexagonal shape. The EDS reports showed that the films contained Cl and Fe. Size analysis was performed using ImageJ software, where the average diameter was found to be 4.8 ± 0.9 μm, and the average thickness was found to be 254 ± 43 nm.
3D printing X-Ray Quality Control Phantoms. A Low Contrast Paradigm
NASA Astrophysics Data System (ADS)
Kapetanakis, I.; Fountos, G.; Michail, C.; Valais, I.; Kalyvas, N.
2017-11-01
Current 3D printing technology products may be usable in various biomedical applications. Such an application is the creation of X-ray quality control phantoms. In this work a self-assembled 3D printer (geeetech i3) was used for the design of a simple low contrast phantom. The printing material was Polylactic Acid (PLA) (100% printing density). Low contrast scheme was achieved by creating air-holes with different diameters and thicknesses, ranging from 1mm to 9mm. The phantom was irradiated at a Philips Diagnost 93 fluoroscopic installation at 40kV-70kV with the semi-automatic mode. The images were recorded with an Agfa cr30-x CR system and assessed with ImageJ software. The best contrast value observed was approximately 33%. In low contrast detectability check it was found that the 1mm diameter hole was always visible, for thickness larger or equal to 4mm. A reason for not being able to distinguish 1mm in smaller thicknesses might be the presence of printing patterns on the final image, which increased the structure noise. In conclusion the construction of a contrast resolution phantom with a 3D printer is feasible. The quality of the final product depends upon the printer accuracy and the material characteristics.
Acanthamoeba migration in an electric field.
Rudell, Jolene Chang; Gao, Jing; Sun, Yuxin; Sun, Yaohui; Chodosh, James; Schwab, Ivan; Zhao, Min
2013-06-21
We investigated the in vitro response of Acanthamoeba trophozoites to electric fields (EFs). Acanthamoeba castellanii were exposed to varying strengths of an EF. During EF exposure, cell migration was monitored using an inverted microscope equipped with a CCD camera and the SimplePCI 5.3 imaging system to capture time-lapse images. The migration of A. castellanii trophozoites was analyzed and quantified with ImageJ software. For analysis of cell migration in a three-dimensional culture system, Acanthamoeba trophozoites were cultured in agar, exposed to an EF, digitally video recorded, and analyzed at various Z focal planes. Acanthamoeba trophozoites move at random in the absence of an EF, but move directionally in response to an EF. Directedness in the absence of an EF is 0.08 ± 0.01, while in 1200 mV/mm EF, directedness is significantly higher at -0.65 ± 0.01 (P < 0.001). We find that the trophozoite migration response is voltage-dependent, with higher directionality with higher voltage application. Acanthamoeba move directionally in a three-dimensional (3D) agar system as well when exposed to an EF. Acanthamoeba trophozoites move directionally in response to an EF in a two-dimensional and 3D culture system. Acanthamoeba trophozoite migration is also voltage-dependent, with increased directionality with increasing voltage. This may provide new treatment modalities for Acanthamoeba keratitis.
Cluster signal-to-noise analysis for evaluation of the information content in an image.
Weerawanich, Warangkana; Shimizu, Mayumi; Takeshita, Yohei; Okamura, Kazutoshi; Yoshida, Shoko; Yoshiura, Kazunori
2018-01-01
(1) To develop an observer-free method of analysing image quality related to the observer performance in the detection task and (2) to analyse observer behaviour patterns in the detection of small mass changes in cone-beam CT images. 13 observers detected holes in a Teflon phantom in cone-beam CT images. Using the same images, we developed a new method, cluster signal-to-noise analysis, to detect the holes by applying various cut-off values using ImageJ and reconstructing cluster signal-to-noise curves. We then evaluated the correlation between cluster signal-to-noise analysis and the observer performance test. We measured the background noise in each image to evaluate the relationship with false positive rates (FPRs) of the observers. Correlations between mean FPRs and intra- and interobserver variations were also evaluated. Moreover, we calculated true positive rates (TPRs) and accuracies from background noise and evaluated their correlations with TPRs from observers. Cluster signal-to-noise curves were derived in cluster signal-to-noise analysis. They yield the detection of signals (true holes) related to noise (false holes). This method correlated highly with the observer performance test (R 2 = 0.9296). In noisy images, increasing background noise resulted in higher FPRs and larger intra- and interobserver variations. TPRs and accuracies calculated from background noise had high correlation with actual TPRs from observers; R 2 was 0.9244 and 0.9338, respectively. Cluster signal-to-noise analysis can simulate the detection performance of observers and thus replace the observer performance test in the evaluation of image quality. Erroneous decision-making increased with increasing background noise.
van Vugt, Jeroen L A; Levolger, Stef; Gharbharan, Arvind; Koek, Marcel; Niessen, Wiro J; Burger, Jacobus W A; Willemsen, Sten P; de Bruin, Ron W F; IJzermans, Jan N M
2017-04-01
The association between body composition (e.g. sarcopenia or visceral obesity) and treatment outcomes, such as survival, using single-slice computed tomography (CT)-based measurements has recently been studied in various patient groups. These studies have been conducted with different software programmes, each with their specific characteristics, of which the inter-observer, intra-observer, and inter-software correlation are unknown. Therefore, a comparative study was performed. Fifty abdominal CT scans were randomly selected from 50 different patients and independently assessed by two observers. Cross-sectional muscle area (CSMA, i.e. rectus abdominis, oblique and transverse abdominal muscles, paraspinal muscles, and the psoas muscle), visceral adipose tissue area (VAT), and subcutaneous adipose tissue area (SAT) were segmented by using standard Hounsfield unit ranges and computed for regions of interest. The inter-software, intra-observer, and inter-observer agreement for CSMA, VAT, and SAT measurements using FatSeg, OsiriX, ImageJ, and sliceOmatic were calculated using intra-class correlation coefficients (ICCs) and Bland-Altman analyses. Cohen's κ was calculated for the agreement of sarcopenia and visceral obesity assessment. The Jaccard similarity coefficient was used to compare the similarity and diversity of measurements. Bland-Altman analyses and ICC indicated that the CSMA, VAT, and SAT measurements between the different software programmes were highly comparable (ICC 0.979-1.000, P < 0.001). All programmes adequately distinguished between the presence or absence of sarcopenia (κ = 0.88-0.96 for one observer and all κ = 1.00 for all comparisons of the other observer) and visceral obesity (all κ = 1.00). Furthermore, excellent intra-observer (ICC 0.999-1.000, P < 0.001) and inter-observer (ICC 0.998-0.999, P < 0.001) agreement for all software programmes were found. Accordingly, excellent Jaccard similarity coefficients were found for all comparisons (mean ≥ 0.964). FatSeg, OsiriX, ImageJ, and sliceOmatic showed an excellent agreement for CSMA, VAT, and SAT measurements on abdominal CT scans. Furthermore, excellent inter-observer and intra-observer agreement were achieved. Therefore, results of studies using these different software programmes can reliably be compared. © 2016 The Authors. Journal of Cachexia, Sarcopenia and Muscle published by John Wiley & Sons Ltd on behalf of the Society on Sarcopenia, Cachexia and Wasting Disorders.
Levolger, Stef; Gharbharan, Arvind; Koek, Marcel; Niessen, Wiro J.; Burger, Jacobus W.A.; Willemsen, Sten P.; de Bruin, Ron W.F.
2016-01-01
Abstract Background The association between body composition (e.g. sarcopenia or visceral obesity) and treatment outcomes, such as survival, using single‐slice computed tomography (CT)‐based measurements has recently been studied in various patient groups. These studies have been conducted with different software programmes, each with their specific characteristics, of which the inter‐observer, intra‐observer, and inter‐software correlation are unknown. Therefore, a comparative study was performed. Methods Fifty abdominal CT scans were randomly selected from 50 different patients and independently assessed by two observers. Cross‐sectional muscle area (CSMA, i.e. rectus abdominis, oblique and transverse abdominal muscles, paraspinal muscles, and the psoas muscle), visceral adipose tissue area (VAT), and subcutaneous adipose tissue area (SAT) were segmented by using standard Hounsfield unit ranges and computed for regions of interest. The inter‐software, intra‐observer, and inter‐observer agreement for CSMA, VAT, and SAT measurements using FatSeg, OsiriX, ImageJ, and sliceOmatic were calculated using intra‐class correlation coefficients (ICCs) and Bland–Altman analyses. Cohen's κ was calculated for the agreement of sarcopenia and visceral obesity assessment. The Jaccard similarity coefficient was used to compare the similarity and diversity of measurements. Results Bland–Altman analyses and ICC indicated that the CSMA, VAT, and SAT measurements between the different software programmes were highly comparable (ICC 0.979–1.000, P < 0.001). All programmes adequately distinguished between the presence or absence of sarcopenia (κ = 0.88–0.96 for one observer and all κ = 1.00 for all comparisons of the other observer) and visceral obesity (all κ = 1.00). Furthermore, excellent intra‐observer (ICC 0.999–1.000, P < 0.001) and inter‐observer (ICC 0.998–0.999, P < 0.001) agreement for all software programmes were found. Accordingly, excellent Jaccard similarity coefficients were found for all comparisons (mean ≥ 0.964). Conclusions FatSeg, OsiriX, ImageJ, and sliceOmatic showed an excellent agreement for CSMA, VAT, and SAT measurements on abdominal CT scans. Furthermore, excellent inter‐observer and intra‐observer agreement were achieved. Therefore, results of studies using these different software programmes can reliably be compared. PMID:27897414
Campagnolo, Marcelo Ivo; Reis, Ricardo Dos; Santos, Marcele Oliveira Dos; Kliemann, Lúcia Maria; Savaris, Ricardo Francalacci
2018-05-29
To determine which mode and potency of electrocoagulation, using a modern electrosurgical generator, yields the smallest unobstructed area of the Fallopian tubes. In an experimental study, tubes from 48 hysterectomies or tubal ligation were evaluated. Tubes were randomly allocated to one of the following groups: group A) 25 W x 5 seconds ( n = 17); group B) 30 W x 5 seconds ( n = 17); group C) 35 W x 5 seconds ( n = 18), group D) 40 W x 5 seconds ( n = 20); group E) 40 W x 5 seconds with visual inspection (blanch, swells, collapse) ( n = 16); group F) 50 W x 5 seconds ( n = 8). Bipolar electrocoagulation was performed in groups A to E, and monopolar electrocoagulation was performed in group F. Coagulation mode was used in all groups. Digital photomicrography of the transversal histological sections of the isthmic segment of the Fallopian tube were taken, and the median percentage of unobstructed luminal area (mm 2 ) was measured with ImageJ software (ImageJ, National Institutes of Health, Bethesda, MD, USA). The Kruskal-Wallis test or analysis of variance (ANOVA) was used for statistical analysis. Ninety-six Fallopian tube sections were analyzed. The smallest median occluded area (%; range) of the Fallopian tube was obtained in the group with 40 W with visual inspection (8.3%; 0.9-40%), followed by the groups 25 W (9.1%; 0-35.9%), 40 W (14.2; 0.9-43.2%), 30 W (14.2; 0.9-49.7%), 35 W (15.1; 3-46.4%) and 50 W (38.2; 3.1-51%). No statistically significant difference was found among groups ( p = 0.09, Kruskal-Wallis test). The smallest unobstructed area was obtained with power setting at 40 W with visual inspection using a modern electrosurgical generator. However, no statistically significant difference in the unobstructed area was observed among the groups using these different modes and potencies. Thieme Revinter Publicações Ltda Rio de Janeiro, Brazil.
Oliveira, M; Lopez, G; Geambastiani, P; Ubeda, C
2018-05-01
A quality assurance (QA) program is a valuable tool for the continuous production of optimal quality images. The aim of this paper is to assess a newly developed automatic computer software for image quality (IR) evaluation in fluoroscopy X-ray systems. Test object images were acquired using one fluoroscopy system, Siemens Axiom Artis model (Siemens AG, Medical Solutions Erlangen, Germany). The software was developed as an ImageJ plugin. Two image quality parameters were assessed: high-contrast spatial resolution (HCSR) and signal-to-noise ratio (SNR). The time between manual and automatic image quality assessment procedures were compared. The paired t-test was used to assess the data. p Values of less than 0.05 were considered significant. The Fluoro-QC software generated faster IQ evaluation results (mean = 0.31 ± 0.08 min) than manual procedure (mean = 4.68 ± 0.09 min). The mean difference between techniques was 4.36 min. Discrepancies were identified in the region of interest (ROI) areas drawn manually with evidence of user dependence. The new software presented the results of two tests (HCSR = 3.06, SNR = 5.17) and also collected information from the DICOM header. Significant differences were not identified between manual and automatic measures of SNR (p value = 0.22) and HCRS (p value = 0.46). The Fluoro-QC software is a feasible, fast and free to use method for evaluating imaging quality parameters on fluoroscopy systems. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
Czwoydzinski, J; Girnus, R; Sommer, A; Heindel, W; Lenzen, H
2011-09-01
Physical-technical quality assurance is one of the essential tasks of the National Reference Centers in the German Breast Cancer Screening Program. For this purpose the mammography units are required to transfer the measured values of the constancy tests on a daily basis and all phantom images created for this purpose on a weekly basis to the reference centers. This is a serious logistical challenge. To meet these requirements, we developed an innovative software tool. By the end of 2005, we had already developed web-based software (MammoControl) allowing the transmission of constancy test results via entry forms. For automatic analysis and transmission of the phantom images, we then introduced an extension (MammoControl DIANA). This was based on Java, Java Web Start, the NetBeans Rich Client Platform, the Pixelmed Java DICOM Toolkit and the ImageJ library. MammoControl DIANA was designed to run locally in the mammography units. This allows automated on-site image analysis. Both results and compressed images can then be transmitted to the reference center. We developed analysis modules for the daily and monthly consistency tests and additionally for a homogeneity test. The software we developed facilitates the immediate availability of measurement results, phantom images, and DICOM header data in all reference centers. This allows both targeted guidance and short response time in the case of errors. We achieved a consistent IT-based evaluation with standardized tools for the entire screening program in Germany. © Georg Thieme Verlag KG Stuttgart · New York.
Xu, Najia; Lei, Xi; Liu, Lixin
2011-09-24
The recruitment of circulating leukocytes from blood stream to the inflamed tissue is a crucial and complex process of inflammation(1,2). In the postcapillary venules of inflamed tissue, leukocytes initially tether and roll on the luminal surface of venular wall. Rolling leukocytes arrest on endothelium and undergo firm adhesion in response to chemokine or other chemoattractants on the venular surface. Many adherent leukocytes relocate from the initial site of adhesion to the junctional extravasation site in endothelium, a process termed intraluminal crawling(3). Following crawling, leukocytes move across endothelium (transmigration) and migrate in extravascular tissue toward the source of chemoattractant (chemotaxis)(4). Intravital microscopy is a powerful tool for visualizing leukocyte-endothelial cell interactions in vivo and revealing cellular and molecular mechanisms of leukocyte recruitment(2,5). In this report, we provide a comprehensive description of using brightfield intravital microscopy to visualize and determine the detailed processes of neutrophil recruitment in mouse cremaster muscle in response to the gradient of a neutrophil chemoattractant. To induce neutrophil recruitment, a small piece of agarose gel (~1-mm(3) size) containing neutrophil chemoattractant MIP-2 (CXCL2, a CXC chemokine) or WKYMVm (Trp-Lys-Tyr-Val-D-Met, a synthetic analog of bacterial peptide) is placed on the muscle tissue adjacent to the observed postcapillary venule. With time-lapsed video photography and computer software ImageJ, neutrophil intraluminal crawling on endothelium, neutrophil transendothelial migration and the migration and chemotaxis in tissue are visualized and tracked. This protocol allows reliable and quantitative analysis of many neutrophil recruitment parameters such as intraluminal crawling velocity, transmigration time, detachment time, migration velocity, chemotaxis velocity and chemotaxis index in tissue. We demonstrate that using this protocol, these neutrophil recruitment parameters can be stably determined and the single cell locomotion conveniently tracked in vivo.
Grassi, Hilda Cristina; García, Lisbette C; Lobo-Sulbarán, María Lorena; Velásquez, Ana; Andrades-Grassi, Francisco A; Cabrera, Humberto; Andrades-Grassi, Jesús E; Andrades, Efrén D J
2016-12-01
In this paper we report a quantitative laser Biospeckle method using VDRL plates to monitor the activity of Trypanosoma cruzi and the calibration conditions including three image processing algorithms and three programs (ImageJ and two programs designed in this work). Benznidazole was used as a test drug. Variable volume (constant density) and variable density (constant volume) were used for the quantitative evaluation of parasite activity in calibrated wells of the VDRL plate. The desiccation process within the well was monitored as a function of volume and of the activity of the Biospeckle pattern of the parasites as well as the quantitative effect of the surface parasite quantity (proportion of the object's plane). A statistical analysis was performed with ANOVA, Tukey post hoc and Descriptive Statistics using R and R Commander. Conditions of volume (100μl) and parasite density (2-4x104 parasites/well, in exponential growth phase), assay time (up to 204min), frame number (11 frames), algorithm and program (RCommander/SAGA) for image processing were selected to test the effect of variable concentrations of benznidazole (0.0195 to 20μg/mL / 0.075 to 76.8μM) at various times (1, 61, 128 and 204min) on the activity of the Biospeckle pattern. The flat wells of the VDRL plate were found to be suitable for the quantitative calibration of the activity of Trypanosoma cruzi using the appropriate algorithm and program. Under these conditions, benznidazole produces at 1min an instantaneous effect on the activity of the Biospeckle pattern of T. cruzi, which remains with a similar profile up to 1 hour. A second effect which is dependent on concentrations above 1.25μg/mL and is statistically different from the effect at lower concentrations causes a decrease in the activity of the Biospeckle pattern. This effect is better detected after 1 hour of drug action. This behavior may be explained by an instantaneous effect on a membrane protein of Trypanosoma cruzi that could mediate the translocation of benznidazole. At longer times the effect may possibly be explained by the required transformation of the pro-drug into the active drug.
Piersma, Sjouke; Denham, Emma L; Drulhe, Samuel; Tonk, Rudi H J; Schwikowski, Benno; van Dijl, Jan Maarten
2013-01-01
Gene expression heterogeneity is a key driver for microbial adaptation to fluctuating environmental conditions, cell differentiation and the evolution of species. This phenomenon has therefore enormous implications, not only for life in general, but also for biotechnological applications where unwanted subpopulations of non-producing cells can emerge in large-scale fermentations. Only time-lapse fluorescence microscopy allows real-time measurements of gene expression heterogeneity. A major limitation in the analysis of time-lapse microscopy data is the lack of fast, cost-effective, open, simple and adaptable protocols. Here we describe TLM-Quant, a semi-automatic pipeline for the analysis of time-lapse fluorescence microscopy data that enables the user to visualize and quantify gene expression heterogeneity. Importantly, our pipeline builds on the open-source packages ImageJ and R. To validate TLM-Quant, we selected three possible scenarios, namely homogeneous expression, highly 'noisy' heterogeneous expression, and bistable heterogeneous expression in the Gram-positive bacterium Bacillus subtilis. This bacterium is both a paradigm for systems-level studies on gene expression and a highly appreciated biotechnological 'cell factory'. We conclude that the temporal resolution of such analyses with TLM-Quant is only limited by the numbers of recorded images.
AlQahtani, Nabeeh A.; Haralur, Satheesh B.; AlMaqbol, Mohammad; AlMufarrij, Ali Jubran; Al Dera, Ahmed Ali; Al-Qarni, Mohammed
2016-01-01
Objectives: To determine the occurrence of smile line and maxillary tooth shape in the Saudi Arabian subpopulation, and to estimate the association between these parameters with gingival biotype. Materials and Methods: On the fulfillment of selection criteria, total 315 patients belong to Saudi Arabian ethnic group were randomly selected. Two frontal photographs of the patients were acquired. The tooth morphology, gingival angle, and smile line classification were determined with ImageJ image analyzing software. The gingival biotype was assessed by probe transparency method. The obtained data were analyzed with SPSS 19 (IBM Corporation, New York, USA) software to determine the frequency and association between other parameters and gingival biotype. Results: Among the clinical parameters evaluated, the tapering tooth morphology (56.8%), thick gingival biotype (53%), and average smile line (57.5%) was more prevalent. The statistically significant association was found between thick gingival biotype and the square tooth, high smile line. The high gingival angle was associated with thin gingival biotype. Conclusions: The study results indicate the existence of an association between tooth shape, smile line, and gingival angle with gingival biotype. PMID:27195228
Image quality and absorbed dose comparison of single- and dual-source cone-beam computed tomography.
Miura, Hideharu; Ozawa, Shuichi; Okazue, Toshiya; Kawakubo, Atsushi; Yamada, Kiyoshi; Nagata, Yasushi
2018-05-01
Dual-source cone-beam computed tomography (DCBCT) is currently available in the Vero4DRT image-guided radiotherapy system. We evaluated the image quality and absorbed dose for DCBCT and compared the values with those for single-source CBCT (SCBCT). Image uniformity, Hounsfield unit (HU) linearity, image contrast, and spatial resolution were evaluated using a Catphan phantom. The rotation angle for acquiring SCBCT and DCBCT images is 215° and 115°, respectively. The image uniformity was calculated using measurements obtained at the center and four peripheral positions. The HUs of seven materials inserted into the phantom were measured to evaluate HU linearity and image contrast. The Catphan phantom was scanned with a conventional CT scanner to measure the reference HU for each material. The spatial resolution was calculated using high-resolution pattern modules. Image quality was analyzed using ImageJ software ver. 1.49. The absorbed dose was measured using a 0.6-cm 3 ionization chamber with a 16-cm-diameter cylindrical phantom, at the center and four peripheral positions of the phantom, and calculated using weighted cone-beam CT dose index (CBCTDI w ). Compared with that of SCBCT, the image uniformity of DCBCT was slightly reduced. A strong linear correlation existed between the measured HU for DCBCT and the reference HU, although the linear regression slope was different from that of the reference HU. DCBCT had poorer image contrast than did SCBCT, particularly with a high-contrast material. There was no significant difference between the spatial resolutions of SCBCT and DCBCT. The absorbed dose for DCBCT was higher than that for SCBCT, because in DCBCT, the two x-ray projections overlap between 45° and 70°. We found that the image quality was poorer and the absorbed dose was higher for DCBCT than for SCBCT in the Vero4DRT. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
Yu, Ying-Song; Xia, Xue-Lian; Zheng, Xu; Huang, Xianfu; Zhou, Jin-Zhi
2017-09-01
In this paper, evaporation of sessile water droplets containing fluorescent polystyrene (PS) microparticles on polydimethylsiloxane (PDMS) surfaces with different curing ratios was studied experimentally using laser confocal microscopy. At the beginning, there were some microparticles located at the contact line and some microparticles moved towards the line. Due to contact angle hysteresis, at first both the contact line and the microparticles were pinned. With the depinning contact line, the microparticles moved together spontaneously. Using the software ImageJ, the location of contact lines at different time were acquired and the circle centers and radii of the contact lines were obtained via the least square method. Then the average distance of two neighbor contact lines at a certain time interval was obtained to characterize the motion of the contact line. Fitting the distance-time curve at the depinning contact line stage with polynomials and differentiating the polynomials with time, we obtained the velocity and acceleration of both the contact line and the microparticles located at the line. The velocity and the maximum acceleration were, respectively, of the orders of 1 μm/s and 20-200 nm/s2, indicating that the motion of the microparticles located at the depinning contact line was quasi-static. Finally, we presented a theoretical model to describe the quasi-static process, which may help in understanding both self-pinning and depinning of microparticles.
Conditions Affecting Social Space in Drosophila melanogaster.
McNeil, Alison R; Jolley, Sam N; Akinleye, Adesanya A; Nurilov, Marat; Rouzyi, Zulekha; Milunovich, Austin J; Chambers, Moria C; Simon, Anne F
2015-11-05
The social space assay described here can be used to quantify social interactions of Drosophila melanogaster - or other small insects - in a straightforward manner. As we previously demonstrated (1), in a two-dimensional chamber, we first force the flies to form a tight group, subsequently allowing them to take their preferred distance from each other. After the flies have settled, we measure the distance to the closest neighbor (or social space), processing a static picture with free online software (ImageJ). The analysis of the distance to the closest neighbor allows researchers to determine the effects of genetic and environmental factors on social interaction, while controlling for potential confounding factors. Diverse factors such as climbing ability, time of day, sex, and number of flies, can modify social spacing of flies. We thus propose a series of experimental controls to mitigate these confounding effects. This assay can be used for at least two purposes. First, researchers can determine how their favorite environmental shift (such as isolation, temperature, stress or toxins) will impact social spacing (1,2). Second, researchers can dissect the genetic and neural underpinnings of this basic form of social behavior (1,3). Specifically, we used it as a diagnostic tool to study the role of orthologous genes thought to be involved in social behavior in other organisms, such as candidate genes for autism in humans (4).
Beyond filtered backprojection: A reconstruction software package for ion beam microtomography data
NASA Astrophysics Data System (ADS)
Habchi, C.; Gordillo, N.; Bourret, S.; Barberet, Ph.; Jovet, C.; Moretto, Ph.; Seznec, H.
2013-01-01
A new version of the TomoRebuild data reduction software package is presented, for the reconstruction of scanning transmission ion microscopy tomography (STIMT) and particle induced X-ray emission tomography (PIXET) images. First, we present a state of the art of the reconstruction codes available for ion beam microtomography. The algorithm proposed here brings several advantages. It is a portable, multi-platform code, designed in C++ with well-separated classes for easier use and evolution. Data reduction is separated in different steps and the intermediate results may be checked if necessary. Although no additional graphic library or numerical tool is required to run the program as a command line, a user friendly interface was designed in Java, as an ImageJ plugin. All experimental and reconstruction parameters may be entered either through this plugin or directly in text format files. A simple standard format is proposed for the input of experimental data. Optional graphic applications using the ROOT interface may be used separately to display and fit energy spectra. Regarding the reconstruction process, the filtered backprojection (FBP) algorithm, already present in the previous version of the code, was optimized so that it is about 10 times as fast. In addition, Maximum Likelihood Expectation Maximization (MLEM) and its accelerated version Ordered Subsets Expectation Maximization (OSEM) algorithms were implemented. A detailed user guide in English is available. A reconstruction example of experimental data from a biological sample is given. It shows the capability of the code to reduce noise in the sinograms and to deal with incomplete data, which puts a new perspective on tomography using low number of projections or limited angle.
Histomorphometric analysis of collagen architecture of auricular keloids in an Asian population.
Chong, Yosep; Park, Tae Hwan; Seo, Sang won; Chang, Choong Hyun
2015-03-01
Keloids are a pathologic condition of the reparative process, which present as excessive scar formation that involves various cells and cytokines. Many studies focusing on the histologic feature of keloids, however, have shown discordant results without consideration of architectural aspect of collagen structure. The purpose of this study was to demonstrate a schematic illustration of collagen architecture of keloids, specifically auricular keloids, and to analyze each part on the histomorphologic and morphometric basis. Thirty-nine surgically excised auricular keloids were retrieved from the file of Kangbuk Samsung Hospital. After exhaustive histomorphologic analysis, 3 distinctive structural parts, keloidal collagen, organizing collagen, and proliferating core collagen, were identified and mapped in every case. Cellularity of fibroblasts, blood vessel density, degree of inflammatory cell infiltration, and mast cells counts using Masson trichrome stain, Van Gieson stain, toluidine blue stain, and immunohistochemical stains for CD31 and smooth muscle actin were analyzed in each part of each case. Morphometric analysis on these parameters using ImageJ software was performed using 3 representative images of each part. Three parts were histomorphologically distinct by shape and array of collagen bundles, fibroblasts cellularity, blood vessel density, degree of inflammatory cells, and mast cell infiltration. Morphometric analysis revealed statistically significant difference between each part in fibroblasts cellularity, blood vessel density, degree of inflammatory cell infiltration, and mast cells count. All parameters were exceedingly high in whorling hypercellular fibrous nodules in proliferating core collagen showing simultaneous changes in other parts. Morphologically and morphometrically, 3 distinctive parts were identified in auricular keloids. Mast cell infiltrations, blood vessel density, and fibroblast cellularity are simultaneously increased or decreased according to these parts. Proliferating core collagen might serve as a proliferating center of keloids and might be a key portion for tumor growth and recurrence.
Kuehl, Kristin; Jones, Ross; Gibbs, David; Richardson, Laurie
2011-03-01
On Bermuda reefs the brain coral Diploria labyrinthiformis is rarely documented with black band disease (BBD), while BBD-affected colonies of Diploria strigosa are common. D. labyrinthiformis on these reefs may be more resistant to BBD or less affected by prevailing environmental conditions that potentially diminish host defenses. To determine whether light and/or temperature influence BBD differently on these two species, infection experiments were conducted under the following experimental treatments: (1) 26 °C, ambient light; (2) 30 °C, ambient light; (3) 30 °C, low light; and (4) 30 °C, high light. A digital photograph of the affected area of each coral was taken each day for 7 days and analyzed with ImageJ image processing software. The final affected area was not significantly different between species in any of the four treatments. BBD lesions were smaller on both species infected under ambient light at 26 °C versus 30 °C. Low light at 30 °C significantly reduced the lesion size on both species when compared to colonies infected at the same temperature under ambient light. Under high light at 30 °C, BBD lesions were larger on colonies of D. strigosa and smaller on colonies of D. labyrinthiformis when compared to colonies infected under ambient light at the same temperature. The responses of both species suggests that BBD progression on both D. strigosa and D. labyrinthiformis is similarly influenced by a combination of light and temperature and that other factors present before infections become established likely contribute to the difference in BBD prevalence in Bermuda. Copyright © 2010 Elsevier Inc. All rights reserved.
Experimental study on foam coverage on simulated longwall roof.
Reed, W R; Zheng, Y; Klima, S; Shahan, M R; Beck, T W
2017-01-01
Testing was conducted to determine the ability of foam to maintain roof coverage in a simulated longwall mining environment. Approximately 27 percent of respirable coal mine dust can be attributed to longwall shield movement, and developing controls for this dust source has been difficult. The application of foam is a possible dust control method for this source. Laboratory testing of two foam agents was conducted to determine the ability of the foam to adhere to a simulated longwall face roof surface. Two different foam generation methods were used: compressed air and blower air. Using a new imaging technology, image processing and analysis utilizing ImageJ software produced quantifiable results of foam roof coverage. For compressed air foam in 3.3 m/s (650 fpm) ventilation, 98 percent of agent A was intact while 95 percent of agent B was intact on the roof at three minutes after application. At 30 minutes after application, 94 percent of agent A was intact while only 20 percent of agent B remained. For blower air in 3.3 m/s (650 fpm) ventilation, the results were dependent upon nozzle type. Three different nozzles were tested. At 30 min after application, 74 to 92 percent of foam agent A remained, while 3 to 50 percent of foam agent B remained. Compressed air foam seems to remain intact for longer durations and is easier to apply than blower air foam. However, more water drained from the foam when using compressed air foam, which demonstrates that blower air foam retains more water at the roof surface. Agent A seemed to be the better performer as far as roof application is concerned. This testing demonstrates that roof application of foam is feasible and is able to withstand a typical face ventilation velocity, establishing this technique's potential for longwall shield dust control.
Experimental study on foam coverage on simulated longwall roof
Reed, W.R.; Zheng, Y.; Klima, S.; Shahan, M.R.; Beck, T.W.
2018-01-01
Testing was conducted to determine the ability of foam to maintain roof coverage in a simulated longwall mining environment. Approximately 27 percent of respirable coal mine dust can be attributed to longwall shield movement, and developing controls for this dust source has been difficult. The application of foam is a possible dust control method for this source. Laboratory testing of two foam agents was conducted to determine the ability of the foam to adhere to a simulated longwall face roof surface. Two different foam generation methods were used: compressed air and blower air. Using a new imaging technology, image processing and analysis utilizing ImageJ software produced quantifiable results of foam roof coverage. For compressed air foam in 3.3 m/s (650 fpm) ventilation, 98 percent of agent A was intact while 95 percent of agent B was intact on the roof at three minutes after application. At 30 minutes after application, 94 percent of agent A was intact while only 20 percent of agent B remained. For blower air in 3.3 m/s (650 fpm) ventilation, the results were dependent upon nozzle type. Three different nozzles were tested. At 30 min after application, 74 to 92 percent of foam agent A remained, while 3 to 50 percent of foam agent B remained. Compressed air foam seems to remain intact for longer durations and is easier to apply than blower air foam. However, more water drained from the foam when using compressed air foam, which demonstrates that blower air foam retains more water at the roof surface. Agent A seemed to be the better performer as far as roof application is concerned. This testing demonstrates that roof application of foam is feasible and is able to withstand a typical face ventilation velocity, establishing this technique’s potential for longwall shield dust control. PMID:29563765
Honeker, Linnea K; Root, Robert A; Chorover, Jon; Maier, Raina M
2016-12-01
Metal(loid)-contamination of the environment due to anthropogenic activities is a global problem. Understanding the fate of contaminants requires elucidation of biotic and abiotic factors that influence metal(loid) speciation from molecular to field scales. Improved methods are needed to assess micro-scale processes, such as those occurring at biogeochemical interfaces between plant tissues, microbial cells, and metal(loid)s. Here we present an advanced method that combines fluorescence in situ hybridization (FISH) with synchrotron-based multiple-energy micro-focused X-ray fluorescence microprobe imaging (ME μXRF) to examine colocalization of bacteria and metal(loid)s on root surfaces of plants used to phytostabilize metalliferous mine tailings. Bacteria were visualized on a small root section using SytoBC nucleic acid stain and FISH probes targeting the domain Bacteria and a specific group (Alphaproteobacteria, Gammaproteobacteria, or Actinobacteria). The same root region was then analyzed for elemental distribution and metal(loid) speciation of As and Fe using ME μXRF. The FISH and ME μXRF images were aligned using ImageJ software to correlate microbiological and geochemical results. Results from quantitative analysis of colocalization show a significantly higher fraction of As colocalized with Fe-oxide plaques on the root surfaces (fraction of overlap 0.49±0.19) than to bacteria (0.072±0.052) (p<0.05). Of the bacteria that colocalized with metal(loid)s, Actinobacteria, known for their metal tolerance, had a higher correlation with both As and Fe than Alphaproteobacteria or Gammaproteobacteria. This method demonstrates how coupling these micro-techniques can expand our understanding of micro-scale interactions between roots, metal(loid)s and microbes, information that should lead to improved mechanistic models of metal(loid) speciation and fate. Copyright © 2016 Elsevier B.V. All rights reserved.
Water Migration and Swelling in Bentonite Quantified using Neutron Radiography
NASA Astrophysics Data System (ADS)
Vial, A.; DiStefano, V. H.; Perfect, E.; Hale, R. E.; Anovitz, L. M.; McFarlane, J.
2016-12-01
Permanent disposal of radioactive waste remains a critical challenge for the nation's energy future. All disposal system concepts include interfaces between engineered systems and natural materials requiring extensive characterization. Bentonite is often used to buffer subsurface disposal systems from geologic media containing ground water. Bentonite characterization experiments were carried out using the CG-1D neutron imaging beam line at Oak Ridge National Laboratory. Dry bentonite was packed into vertically-oriented aluminum cylinders. Water was ponded on the top surface of each packed cylinder. Images were acquired at 2 min intervals using dynamic neutron radiography. The detector consisted of stacked neutron sensitive microchannel plates above a quad Timepix readout with a 28 x 28 mm2 field of view. The spatial resolution of the detector was 55 μm. Raw neutron radiographs were imported into ImageJ and normalized with respect to the initial completely dry state. The wetting process was 1-dimensional, and vertical intensity profiles were computed by averaging pixel rows. The vertical distance between the clay-water interface and the wetting front could then be determined as a function of time. Depth of water infiltration increased linearly with the square root of time, yielding a sorptivity value of 0.75 (± 0.070) mm/min0.5. Swelling occurred in the form of upward movement of clay particles into the ponded water over time. The resulting low density assemblage was discernable by normalizing the raw profiles with respect to the intensity profile immediately after ponding. The packed clay-water interface was clearly visible in the normalized profiles, and swelling was quantified as the height of the low density assemblage above the original interface. Swelling occurred as a linear function of time, at a rate of 0.054 (± 0.020) mm/min. Further experiments of this type are planned under variable temperature and pressure regimes applicable to subsurface repositories.
Spade, Daniel J; Bai, Cathy Yue; Lambright, Christy; Conley, Justin M; Boekelheide, Kim; Gray, L Earl
2018-06-15
In utero exposure to certain phthalate esters results in testicular toxicity, characterized at the tissue level by induction of multinucleated germ cells (MNGs) in rat, mouse, and human fetal testis. Phthalate exposures also result in a decrease in testicular testosterone in rats. The anti-androgenic effects of phthalates have been more thoroughly quantified than testicular pathology due to the significant time requirement associated with manual counting of MNGs on histological sections. An automated counting method was developed in ImageJ to quantify MNGs in digital images of hematoxylin-stained rat fetal testis tissue sections. Timed pregnant Sprague Dawley rats were exposed by daily oral gavage from gestation day 17 to 21 with one of eight phthalate test compounds or corn oil vehicle. Both the manual counting method and the automated image analysis method identified di-n-butyl phthalate, butyl benzyl phthalate, dipentyl phthalate, and di-(2-ethylhexyl) phthalate as positive for induction of MNGs. Dimethyl phthalate, diethyl phthalate, the brominated phthalate di-(2-ethylhexyl) tetrabromophthalate, and dioctyl terephthalate were negative. The correlation between automated and manual scoring metrics was high (r = 0.923). Results of MNG analysis were consistent with these compounds' anti-androgenic activities, which were confirmed in an ex vivo testosterone production assay. In conclusion, we have developed a reliable image analysis method that can be used to facilitate dose-response studies for the reproducible induction of MNGs by in utero phthalate exposure. Copyright © 2018 Elsevier B.V. All rights reserved.
Skin Dosimetry in Breast Teletherapy on a Phantom Anthropomorphic and Anthropometric Phantom
DOE Office of Scientific and Technical Information (OSTI.GOV)
Batista Nogueira, Luciana; Lemos Silva, Hugo Leonardo; Donato da Silva, Sabrina
This paper addresses the breast teletherapy dosimetry. The goal is to evaluate and compare absorbed doses in equivalent skin tissue, TE-skin, of an anthropomorphic and anthropometric breast phantom submitted to breast radiotherapy. The methodology involved the reproduction of a set of tomographic images of the phantom; the elaboration of conformational radiotherapy planning in the SOMAVISION and CadPlan (TPS) software; and the synthetic breast irradiation by parallel opposed fields in 3D conformal teletherapy at 6 MV linear accelerator Clinac-2100 C from VARIAN with prescribed dose (PD) of 180 cGy to the target volume (PTV), referent to the glandular tissue. Radiochromic filmsmore » EBT2 were selected as dosimeters. Two independent calibration processes of films with solid water Gammex 457 plates and water filled box were produced. Curves of optical density (OD) versus absorbed dose were produced. Dosimeters were positioned in the external region of the breast phantom in contact with TE-skin, area of 4.0 cm{sup 2} each. The irradiation process was prepared in duplicate to check the reproducibility of the technique. The radiochromic films were scanned and their response in RGB (Red, Green, Blue) analyzed by the ImageJ software. The optical density was obtained and converted to dose based on the calibration curves. Thus, the spatial dose distribution in the skin was reproduced. The absorbed doses measured on the radiochromic films in TE-skin showed values between upper and lower quadrants at 9 o'clock in the range of 54% of PD, between the upper and lower quadrants 3 o'clock in the range of 72% and 6 o'clock at the lower quadrant in the range of 68 % of PD. The values are ±64% (p <0.05) according to the TPS. It is concluded that the depth dose measured in solid water plates or water box reproduce equivalent dose values for both calibration processes of the radiochromic films. It was observed that the skin received doses ranging from 50% to 78% of the prescribed dose after two parallel opposed irradiation fields. (authors)« less
A new method of detecting changes in corneal health in response to toxic insults.
Khan, Mohammad Faisal Jamal; Nag, Tapas C; Igathinathane, C; Osuagwu, Uchechukwu L; Rubini, Michele
2015-11-01
The size and arrangement of stromal collagen fibrils (CFs) influence the optical properties of the cornea and hence its function. The spatial arrangement of the collagen is still questionable in relation to the diameter of collagen fibril. In the present study, we introduce a new parameter, edge-fibrillar distance (EFD) to measure how two collagen fibrils are spaced with respect to their closest edges and their spatial distribution through normalized standard deviation of EFD (NSDEFD) accessed through the application of two commercially available multipurpose solutions (MPS): ReNu and Hippia. The corneal buttons were soaked separately in ReNu and Hippia MPS for five hours, fixed overnight in 2.5% glutaraldehyde containing cuprolinic blue and processed for transmission electron microscopy. The electron micrographs were processed using ImageJ user-coded plugin. Statistical analysis was performed to compare the image processed equivalent diameter (ED), inter-fibrillar distance (IFD), and EFD of the CFs of treated versus normal corneas. The ReNu-soaked cornea resulted in partly degenerated epithelium with loose hemidesmosomes and Bowman's collagen. In contrast, the epithelium of the cornea soaked in Hippia was degenerated or lost but showed closely packed Bowman's collagen. Soaking the corneas in both MPS caused a statistically significant decrease in the anterior collagen fibril, ED and a significant change in IFD, and EFD than those of the untreated corneas (p<0.05, for all comparisons). The introduction of EFD measurement in the study directly provided a sense of gap between periphery of the collagen bundles, their spatial distribution; and in combination with ED, they showed how the corneal collagen bundles are spaced in relation to their diameters. The spatial distribution parameter NSDEFD indicated that ReNu treated cornea fibrils were uniformly distributed spatially, followed by normal and Hippia. The EFD measurement with relatively lower standard deviation and NSDEFD, a characteristic of uniform CFs distribution, can be an additional parameter used in evaluating collagen organization and accessing the effects of various treatments on corneal health and transparency. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Pena-Verdeal, Hugo; Garcia-Resua, Carlos; Yebra-Pimentel, Eva; Giraldez, Maria J.
2017-08-01
Purpose: Different lower tear meniscus parameters can be clinical assessed on dry eye diagnosis. The aim of this study was to propose and analyse the variability of a semi-automatic method for measuring lower tear meniscus central area (TMCA) by using open source software. Material and methods: On a group of 105 subjects, one video of the lower tear meniscus after fluorescein instillation was generated by a digital camera attached to a slit-lamp. A short light beam (3x5 mm) with moderate illumination in the central portion of the meniscus (6 o'clock) was used. Images were extracted from each video by a masked observer. By using an open source software based on Java (NIH ImageJ), a further observer measured in a masked and randomized order the TMCA in the short light beam illuminated area by two methods: (1) manual method, where TMCA images was "manually" measured; (2) semi-automatic method, where TMCA images were transformed in an 8-bit-binary image, then holes inside this shape were filled and on the isolated shape, the area size was obtained. Finally, both measurements, manual and semi-automatic, were compared. Results: Paired t-test showed no statistical difference between both techniques results (p = 0.102). Pearson correlation between techniques show a significant positive near to perfect correlation (r = 0.99; p < 0.001). Conclusions: This study showed a useful tool to objectively measure the frontal central area of the meniscus in photography by free open source software.
NASA Astrophysics Data System (ADS)
Georgiou, Giota; Verdaasdonk, Rudolf M.; van der Veen, Albert; Klaessens, John H.
2017-02-01
In the development of new near-infrared (NIR) fluorescence dyes for image guided surgery, there is a need for new NIR sensitive camera systems that can easily be adjusted to specific wavelength ranges in contrast the present clinical systems that are only optimized for ICG. To test alternative camera systems, a setup was developed to mimic the fluorescence light in a tissue phantom to measure the sensitivity and resolution. Selected narrow band NIR LED's were used to illuminate a 6mm diameter circular diffuse plate to create uniform intensity controllable light spot (μW-mW) as target/source for NIR camera's. Layers of (artificial) tissue with controlled thickness could be placed on the spot to mimic a fluorescent `cancer' embedded in tissue. This setup was used to compare a range of NIR sensitive consumer's cameras for potential use in image guided surgery. The image of the spot obtained with the cameras was captured and analyzed using ImageJ software. Enhanced CCD night vision cameras were the most sensitive capable of showing intensities < 1 μW through 5 mm of tissue. However, there was no control over the automatic gain and hence noise level. NIR sensitive DSLR cameras proved relative less sensitive but could be fully manually controlled as to gain (ISO 25600) and exposure time and are therefore preferred for a clinical setting in combination with Wi-Fi remote control. The NIR fluorescence testing setup proved to be useful for camera testing and can be used for development and quality control of new NIR fluorescence guided surgery equipment.
Assessing microscope image focus quality with deep learning.
Yang, Samuel J; Berndl, Marc; Michael Ando, D; Barch, Mariya; Narayanaswamy, Arunachalam; Christiansen, Eric; Hoyer, Stephan; Roat, Chris; Hung, Jane; Rueden, Curtis T; Shankar, Asim; Finkbeiner, Steven; Nelson, Philip
2018-03-15
Large image datasets acquired on automated microscopes typically have some fraction of low quality, out-of-focus images, despite the use of hardware autofocus systems. Identification of these images using automated image analysis with high accuracy is important for obtaining a clean, unbiased image dataset. Complicating this task is the fact that image focus quality is only well-defined in foreground regions of images, and as a result, most previous approaches only enable a computation of the relative difference in quality between two or more images, rather than an absolute measure of quality. We present a deep neural network model capable of predicting an absolute measure of image focus on a single image in isolation, without any user-specified parameters. The model operates at the image-patch level, and also outputs a measure of prediction certainty, enabling interpretable predictions. The model was trained on only 384 in-focus Hoechst (nuclei) stain images of U2OS cells, which were synthetically defocused to one of 11 absolute defocus levels during training. The trained model can generalize on previously unseen real Hoechst stain images, identifying the absolute image focus to within one defocus level (approximately 3 pixel blur diameter difference) with 95% accuracy. On a simpler binary in/out-of-focus classification task, the trained model outperforms previous approaches on both Hoechst and Phalloidin (actin) stain images (F-scores of 0.89 and 0.86, respectively over 0.84 and 0.83), despite only having been presented Hoechst stain images during training. Lastly, we observe qualitatively that the model generalizes to two additional stains, Hoechst and Tubulin, of an unseen cell type (Human MCF-7) acquired on a different instrument. Our deep neural network enables classification of out-of-focus microscope images with both higher accuracy and greater precision than previous approaches via interpretable patch-level focus and certainty predictions. The use of synthetically defocused images precludes the need for a manually annotated training dataset. The model also generalizes to different image and cell types. The framework for model training and image prediction is available as a free software library and the pre-trained model is available for immediate use in Fiji (ImageJ) and CellProfiler.
ADC histogram analysis of muscle lymphoma - Correlation with histopathology in a rare entity.
Meyer, Hans-Jonas; Pazaitis, Nikolaos; Surov, Alexey
2018-06-21
Diffusion weighted imaging (DWI) is able to reflect histopathology architecture. A novel imaging approach, namely histogram analysis, is used to further characterize lesion on MRI. The purpose of this study is to correlate histogram parameters derived from apparent diffusion coefficient- (ADC) maps with histopathology parameters in muscle lymphoma. Eight patients (mean age 64.8 years, range 45-72 years) with histopathologically confirmed muscle lymphoma were retrospectively identified. Cell count, total nucleic and average nucleic areas were estimated using ImageJ. Additionally, Ki67-index was calculated. DWI was obtained on a 1.5T scanner by using the b values of 0 and 1000 s/mm2. Histogram analysis was performed as a whole lesion measurement by using a custom-made Matlabbased application. The correlation analysis revealed statistically significant correlation between cell count and ADCmean (p=-0.76, P=0.03) as well with ADCp75 (p=-0.79, P=0.02). Kurtosis and entropy correlated with average nucleic area (p=-0.81, P=0.02, p=0.88, P=0.007, respectively). None of the analyzed ADC parameters correlated with total nucleic area and with Ki67-index. This study identified significant correlations between cellularity and histogram parameters derived from ADC maps in muscle lymphoma. Thus, histogram analysis parameters reflect histopathology in muscle tumors. Advances in knowledge: Whole lesion ADC histogram analysis is able to reflect histopathology parameters in muscle lymphomas.
Natal, Rodrigo A; Vassallo, José; Paiva, Geisilene R; Pelegati, Vitor B; Barbosa, Guilherme O; Mendonça, Guilherme R; Bondarik, Caroline; Derchain, Sophie F; Carvalho, Hernandes F; Lima, Carmen S; Cesar, Carlos L; Sarian, Luís Otávio
2018-04-01
Second-harmonic generation microscopy represents an important tool to evaluate extracellular matrix collagen structure, which undergoes changes during cancer progression. Thus, it is potentially relevant to assess breast cancer development. We propose the use of second-harmonic generation images of tumor stroma selected on hematoxylin and eosin-stained slides to evaluate the prognostic value of collagen fibers analyses in peri and intratumoral areas in patients diagnosed with invasive ductal breast carcinoma. Quantitative analyses of collagen parameters were performed using ImageJ software. These parameters presented significantly higher values in peri than in intratumoral areas. Higher intratumoral collagen uniformity was associated with high pathological stages and with the presence of axillary lymph node metastasis. In patients with immunohistochemistry-based luminal subtype, higher intratumoral collagen uniformity and quantity were independently associated with poorer relapse-free and overall survival, respectively. A multivariate response recursive partitioning model determined 12.857 and 11.894 as the best cut-offs for intratumoral collagen quantity and uniformity, respectively. These values have shown high sensitivity and specificity to differentiate distinct outcomes. Values of intratumoral collagen quantity and uniformity exceeding the cut-offs were strongly associated with poorer relapse-free and overall survival. Our findings support a promising prognostic value of quantitative evaluation of intratumoral collagen by second-harmonic generation imaging mainly in the luminal subtype breast cancer.
Non-invasive and non-destructive measurements of confluence in cultured adherent cell lines.
Busschots, Steven; O'Toole, Sharon; O'Leary, John J; Stordal, Britta
2015-01-01
Many protocols used for measuring the growth of adherent monolayer cells in vitro are invasive, destructive and do not allow for the continued, undisturbed growth of cells within flasks. Protocols often use indirect methods for measuring proliferation. Microscopy techniques can analyse cell proliferation in a non-invasive or non-destructive manner but often use expensive equipment and software algorithms. In this method images of cells within flasks are captured by photographing under a standard inverted phase contract light microscope using a digital camera with a camera lens adaptor. Images are analysed for confluence using ImageJ freeware resulting in a measure of confluence known as an Area Fraction (AF) output. An example of the AF method in use on OVCAR8 and UPN251 cell lines is included. •Measurements of confluence from growing adherent cell lines in cell culture flasks is obtained in a non-invasive, non-destructive, label-free manner.•The technique is quick, affordable and eliminates sample manipulation.•The technique provides an objective, consistent measure of when cells reach confluence and is highly correlated to manual counting with a haemocytometer. The average correlation co-efficient from a Spearman correlation (n = 3) was 0.99 ± 0.008 for OVCAR8 (p = 0.01) and 0.99 ± 0.01 for UPN251 (p = 0.01) cell lines.
Molina, Inmaculada; Lázaro-Ibáñez, Elisa; Pertusa, Jose; Debón, Ana; Martínez-Sanchís, Juan Vicente; Pellicer, Antonio
2014-10-01
The risk of multiple pregnancy to maternal-fetal health can be minimized by reducing the number of embryos transferred. New tools for selecting embryos with the highest implantation potential should be developed. The aim of this study was to evaluate the ability of morphological and morphometric variables to predict implantation by analysing images of embryos. This was a retrospective study of 135 embryo photographs from 112 IVF-ICSI cycles carried out between January and March 2011. The embryos were photographed immediately before transfer using Cronus 3 software. Their images were analysed using the public program ImageJ. Significant effects (P < 0.05), and higher discriminant power to predict implantation were observed for the morphometric embryo variables compared with morphological ones. The features for successfully implanted embryos were as follows: four cells on day 2 of development; all blastomeres with circular shape (roundness factor greater than 0.9), an average zona pellucida thickness of 13 µm and an average of 17695.1 µm² for the embryo area. Embryo size, which is described by its area and the average roundness factor for each cell, provides two objective variables to consider when predicting implantation. This approach should be further investigated for its potential ability to improve embryo scoring. Copyright © 2014 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Natal, Rodrigo de Andrade; Pelegati, Vitor B.; Bondarik, Caroline; Mendonça, Guilherme R.; Derchain, Sophie F.; Lima, Carmen P.; Cesar, Carlos L.; Sarian, Luís. O.; Vassallo, José
2015-07-01
Introduction: In breast cancer (BC), desmoplastic reaction, assembled primarily by fibroblasts, is associated with unfavorable prognosis, but the reason of this fact remains still unclear. In this context, nonlinear optics microscopy, including Fluorescence Lifetime Imaging Microscopy (FLIM), has provided advancement in cellular metabolism research. In this paper, our purpose is to differentiate BC cells metabolism with or without contact to desmoplastic reaction. Formalin fixed, paraffin embedded samples were used at different points of hematoxylin stained sections. Methodology: Sections from 14 patients with invasive ductal breast carcinoma were analyzed with FLIM methodology to NAD(P)H and FAD fluorescence lifetime on a Confocal Upright LSM780 NLO device (Carl Zeiss AG, Germany). Quantification of the fluorescence lifetime and fluorescence intensity was evaluated by SPC Image software (Becker &Hickl) and ImageJ (NIH), respectively. Optical redox ratio was calculated by dividing the FAD fluorescence intensity by NAD(P)H fluorescence intensity. Data value for FLIM measurements and fluorescence intensities were calculated using Wilcoxon test; p< 0.05 was considered significant. Results: BC cells in contact with desmoplastic reaction presented a significantly lower NAD(P)H and FAD fluorescence lifetime. Furthermore, optical redox ratio was also lower in these tumor cells. Conclusion: Our results suggest that contact of BC cells with desmoplastic reaction increase their metabolic activity, which might explain the adverse prognosis of cases associated with higher peritumoral desmoplastic reaction.
Güler, Umut; de Queiroz, José Renato Cavalcanti; de Oliveira, Luiz Fernando Cappa; Canay, Senay; Ozcan, Mutlu
2015-09-01
This study evaluated the effect of binder choice in mixing ceramic powder on the chemical and morphological features between the margin ceramic-framework interfaces. Titanium and zirconia frameworks (15 x 5 x 0.5 mm3) were veneered with margin ceramics prepared with two different binders, namely a) water/conventional or b) wax-based. For each zirconia framework material, four different margin ceramics were used: a- Creation Zi (Creation Willi Geller International); b- GC Initial Zr (GC America); Triceram (Dentaurum); and d- IPS emax (voclar Vivadent). For the titanium framework, three different margin ceramics were used: a- Creation Ti (Creation Willi Geller International); b- Triceram (Dentaurum); and c- VITA Titaniumkeramik (Vita Zahnfabrik). The chemical composition of the framework-margin ceramic interface was analyzed using Energy Dispersive X-ray Spectroscopy (EDS) and porosity level was quantified within the margin ceramic using an image program (ImageJ) from four random areas (100 x 100 pixels) on each SEM image. EDS analysis showed the presence of Carbon at the margin ceramic-framework interface in the groups where wax-based binder technique was used with the concentration being the highest for the IPS emax ZirCAD group. While IPS system (IPS ZirCAD and IPS Emax) presented higher porosity concentration using wax binder, in the other groups wax-based binder reduced the porosity of margin ceramic, except for Titanium - Triceram combination.
Textural changes of FER-A peridotite in time series piston-cylinder experiments at 1.0 GPa, 1300°C
NASA Astrophysics Data System (ADS)
Schwab, B. E.; Mercer, C. N.; Johnston, A.
2012-12-01
A series of eight 1.0 GPa, 1300°C partial melting experiments were performed using FER-A peridotite starting material to investigate potential textural changes in the residual crystalline phases over time. Powdered peridotite with a layer of vitreous carbon spheres as a melt sink were sealed in graphite-lined Pt capsules and run in CaF2 furnace assemblies in 1.27cm piston-cylinder apparatus at the University of Oregon. Run durations ranged from 4 to 128 hours. Experimental charges were mounted in epoxy, cut, and polished for analysis. In a first attempt to quantify the mineral textures, individual 500x BSE images were collected from selected, representative locations on each of the experimental charges using the FEI Quanta 250 ESEM at Humboldt State University. Noran System Seven (NSS) EDS system was used to collect x-ray maps (spectral images) to aid in identification of phases. A combination of image analysis techniques within NSS and ImageJ software are being used to process the images and quantify the mineral textures observed. The goals are to quantify the size, shape, and abundance of residual olivine (ol), orthopyroxene (opx), clinopyroxene (cpx), and spinel crystals within the selected sample areas of the run products. Additional work will be done to compare the results of the selected areas with larger (lower magnification) images acquired using the same techniques. Preliminary results indicate that measurements of average grain area, minimum grain area, and average, maximum, and minimum grain perimeter show the greatest change (generally decreasing) in measurements for ol, opx, and cpx between the shortest-duration, 4-hour, experiment and the subsequent, 8-hour, experiment. The largest relative change in nearly all of these measurements appears to be for cpx. After the initial decrease, preliminary measurements remain relatively constant for ol, opx, and cpx, respectively, in experiments from 8 to 128 hours in duration. In contrast, measured parameters of spinel grains increase from the 4-hour to 8-hour experiment and continue to fluctuate over the time interval investigated. Spinel also represents the smallest number of individual grains (average n = 25) in any experiment. Average aspect ratios for all minerals remain relatively constant (~1.5-2) throughout the time series. Additional measurements and refinements are underway.
Comparing three UV wavelengths for pre‐exposing Gafchromic EBT2 and EBT3 films
Gotanda, Rumi; Gotanda, Tatsuhiro; Akagawa, Takuya; Tanki, Nobuyoshi; Kuwano, Tadao; Yabunaka, Kouichi
2015-01-01
Gafchromic films are used for X‐ray dose measurements during diagnostic examinations and have begun to be used for three‐dimensional X‐ray dose measurements using the high‐resolution characteristics of Gafchromic films for computed tomography. However, the problem of unevenness in Gafchromic film active layers needs to be resolved. Double exposures using X‐rays are performed during therapeutic radiology, although this is difficult for a diagnostic examination because of a heel effect. Thus, it has been suggested that ultraviolet (UV) radiation be used as a substitute for X‐rays. However, the appropriate UV wavelength has not been determined. Thus, we conducted this study to decide an appropriate UV wavelength. UV peak wavelengths of 245 nm (UV‐A), 310 nm (UV‐B), and 365 nm (UV‐C) were used to irradiate EBT2 and EBT3 films. Each UV wavelength was irradiated for 5, 15, 30, and 60 min, and irradiation was then repeated every 60 min up to 360 min. Gafchromic films were scanned after every irradiation using a flatbed scanner. Images were split into RGB images, and red images were analyzed using ImageJ, version 1.44, image analysis software. A region of interest (ROI) one‐half inch in diameter was placed in the center of subtracted Gafchromic film images, and UV irradiation times were plotted against mean pixel values. There were reactions in the front and back of Gafchromic EBT3 and the back of Gafchromic EBT2 with UV‐A and UV‐B. However, UV‐C resulted in some reactions in both sides of Gafchromic EBT2 and EBT3. The UV‐A and UV‐B wavelengths should be used. PACS number(s): 87.53 Bn PMID:26699578
Moon, Andres; Smith, Geoffrey H; Kong, Jun; Rogers, Thomas E; Ellis, Carla L; Farris, Alton B Brad
2018-02-01
Renal allograft rejection diagnosis depends on assessment of parameters such as interstitial inflammation; however, studies have shown interobserver variability regarding interstitial inflammation assessment. Since automated image analysis quantitation can be reproducible, we devised customized analysis methods for CD3+ T-cell staining density as a measure of rejection severity and compared them with established commercial methods along with visual assessment. Renal biopsy CD3 immunohistochemistry slides (n = 45), including renal allografts with various degrees of acute cellular rejection (ACR) were scanned for whole slide images (WSIs). Inflammation was quantitated in the WSIs using pathologist visual assessment, commercial algorithms (Aperio nuclear algorithm for CD3+ cells/mm 2 and Aperio positive pixel count algorithm), and customized open source algorithms developed in ImageJ with thresholding/positive pixel counting (custom CD3+%) and identification of pixels fulfilling "maxima" criteria for CD3 expression (custom CD3+ cells/mm 2 ). Based on visual inspections of "markup" images, CD3 quantitation algorithms produced adequate accuracy. Additionally, CD3 quantitation algorithms correlated between each other and also with visual assessment in a statistically significant manner (r = 0.44 to 0.94, p = 0.003 to < 0.0001). Methods for assessing inflammation suggested a progression through the tubulointerstitial ACR grades, with statistically different results in borderline versus other ACR types, in all but the custom methods. Assessment of CD3-stained slides using various open source image analysis algorithms presents salient correlations with established methods of CD3 quantitation. These analysis techniques are promising and highly customizable, providing a form of on-slide "flow cytometry" that can facilitate additional diagnostic accuracy in tissue-based assessments.
Lindsey, Benjamin W; Douek, Alon M; Loosli, Felix; Kaslin, Jan
2017-01-01
The field of macro-imaging has grown considerably with the appearance of innovative clearing methods and confocal microscopes with lasers capable of penetrating increasing tissue depths. The ability to visualize and model the growth of whole organs as they develop from birth, or with manipulation, disease or injury, provides new ways of thinking about development, tissue-wide signaling, and cell-to-cell interactions. The zebrafish ( Danio rerio ) has ascended from a predominantly developmental model to a leading adult model of tissue regeneration. The unmatched neurogenic and regenerative capacity of the mature central nervous system, in particular, has received much attention, however tools to interrogate the adult brain are sparse. At present there exists no straightforward methods of visualizing changes in the whole adult brain in 3-dimensions (3-D) to examine systemic patterns of cell proliferation or cell populations of interest under physiological, injury, or diseased conditions. The method presented here is the first of its kind to offer an efficient step-by-step pipeline from intraperitoneal injections of the proliferative marker, 5-ethynyl-2'-deoxyuridine (EdU), to whole brain labeling, to a final embedded and cleared brain sample suitable for 3-D imaging using optical projection tomography (OPT). Moreover, this method allows potential for imaging GFP-reporter lines and cell-specific antibodies in the presence or absence of EdU. The small size of the adult zebrafish brain, the highly consistent degree of EdU labeling, and the use of basic clearing agents, benzyl benzoate, and benzyl alcohol, makes this method highly tractable for most laboratories interested in understanding the vertebrate central nervous system in health and disease. Post-processing of OPT-imaged adult zebrafish brains injected with EdU illustrate that proliferative patterns in EdU can readily be observed and analyzed using IMARIS and/or FIJI/IMAGEJ software. This protocol will be a valuable tool to unlock new ways of understanding systemic patterns in cell proliferation in the healthy and injured brain, brain-wide cellular interactions, stem cell niche development, and changes in brain morphology.
Lindsey, Benjamin W.; Douek, Alon M.; Loosli, Felix; Kaslin, Jan
2018-01-01
The field of macro-imaging has grown considerably with the appearance of innovative clearing methods and confocal microscopes with lasers capable of penetrating increasing tissue depths. The ability to visualize and model the growth of whole organs as they develop from birth, or with manipulation, disease or injury, provides new ways of thinking about development, tissue-wide signaling, and cell-to-cell interactions. The zebrafish (Danio rerio) has ascended from a predominantly developmental model to a leading adult model of tissue regeneration. The unmatched neurogenic and regenerative capacity of the mature central nervous system, in particular, has received much attention, however tools to interrogate the adult brain are sparse. At present there exists no straightforward methods of visualizing changes in the whole adult brain in 3-dimensions (3-D) to examine systemic patterns of cell proliferation or cell populations of interest under physiological, injury, or diseased conditions. The method presented here is the first of its kind to offer an efficient step-by-step pipeline from intraperitoneal injections of the proliferative marker, 5-ethynyl-2′-deoxyuridine (EdU), to whole brain labeling, to a final embedded and cleared brain sample suitable for 3-D imaging using optical projection tomography (OPT). Moreover, this method allows potential for imaging GFP-reporter lines and cell-specific antibodies in the presence or absence of EdU. The small size of the adult zebrafish brain, the highly consistent degree of EdU labeling, and the use of basic clearing agents, benzyl benzoate, and benzyl alcohol, makes this method highly tractable for most laboratories interested in understanding the vertebrate central nervous system in health and disease. Post-processing of OPT-imaged adult zebrafish brains injected with EdU illustrate that proliferative patterns in EdU can readily be observed and analyzed using IMARIS and/or FIJI/IMAGEJ software. This protocol will be a valuable tool to unlock new ways of understanding systemic patterns in cell proliferation in the healthy and injured brain, brain-wide cellular interactions, stem cell niche development, and changes in brain morphology. PMID:29386991
Label-free immunosensor based on gold nanoparticle silver enhancement.
Yang, Minghui; Wang, Cunchang
2009-02-01
A label-free immunosensor for the sensitive detection of human immunoglobulin G (IgG) was prepared based on gold nanoparticle-silver enhancement detection with a simple charge-coupled device (CCD) detector. The gold nanoparticles, which were used as nuclei for the deposit of metallic silver and also for the adsorption of antibodies, were immobilized into wells of a 9-well chip. With the addition of silver enhancement buffer, metallic silver will deposit onto gold nanoparticles, causing darkness that can be optically measured by the CCD camera and quantified using ImageJ software. When antibody was immobilized onto the gold nanoparticles and antigen was captured, the formed immunocomplex resulted in a decrease of the darkness and the intensity of the darkness was in line with IgG concentrations from 0.05 to 10 ng/ml. The CCD detector is simple and portable, and the reported method has many desirable merits such as sensitivity and accuracy, making it a promising technique for protein detection.
Kinashi, Yuko; Yokomizo, Natsuya; Takahashi, Sentaro
2017-04-01
To use the 53BP1 foci assay to detect DNA double-strand breaks induced by fractionated neutron beam irradiation of normal cells. The Kyoto University Research Reactor heavy-water facility and gamma-ray irradiation system were used as experimental radiation sources. After fixation of Chinese Hamster Ovary cells with 3.6% formalin, immunofluorescence staining was performed. Number and size of foci were analyzed using ImageJ software. Fractionated neutron irradiation induced 25% fewer 53BP1 foci than single irradiation at the same dose. By contrast, gamma irradiation induced 30% fewer 53BP1 foci than single irradiation at the same dose. Fractionated neutron irradiation induced larger foci than gamma irradiation, raising the possibility that persistent unrepaired DNA damage was amplified due to the high linear energy transfer component in the neutron beam. Unrepaired cluster DNA damage was more prevalent after fractionated neutron irradiation than after gamma irradiation. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Piersma, Sjouke; Denham, Emma L.; Drulhe, Samuel; Tonk, Rudi H. J.; Schwikowski, Benno; van Dijl, Jan Maarten
2013-01-01
Gene expression heterogeneity is a key driver for microbial adaptation to fluctuating environmental conditions, cell differentiation and the evolution of species. This phenomenon has therefore enormous implications, not only for life in general, but also for biotechnological applications where unwanted subpopulations of non-producing cells can emerge in large-scale fermentations. Only time-lapse fluorescence microscopy allows real-time measurements of gene expression heterogeneity. A major limitation in the analysis of time-lapse microscopy data is the lack of fast, cost-effective, open, simple and adaptable protocols. Here we describe TLM-Quant, a semi-automatic pipeline for the analysis of time-lapse fluorescence microscopy data that enables the user to visualize and quantify gene expression heterogeneity. Importantly, our pipeline builds on the open-source packages ImageJ and R. To validate TLM-Quant, we selected three possible scenarios, namely homogeneous expression, highly ‘noisy’ heterogeneous expression, and bistable heterogeneous expression in the Gram-positive bacterium Bacillus subtilis. This bacterium is both a paradigm for systems-level studies on gene expression and a highly appreciated biotechnological ‘cell factory’. We conclude that the temporal resolution of such analyses with TLM-Quant is only limited by the numbers of recorded images. PMID:23874729
Surface Area of Patellar Facets: Inferential Statistics in the Iraqi Population
Al-Zamili, Zaid; Omar, Rawan
2017-01-01
Background. The patella is the largest sesamoid bone in the body; its three-dimensional complexity necessitates biomechanical perfection. Numerous pathologies occur at the patellofemoral unit which may end in degenerative changes. This study aims to test the presence of statistical correlation between the surface areas of patellar facets and other patellar morphometric parameters. Materials and Methods. Forty dry human patellae were studied. The morphometry of each patella was measured using a digital Vernier Caliper, electronic balance, and image analyses software known as ImageJ. The patellar facetal surface area was correlated with patellar weight, height, width, and thickness. Results. Inferential statistics proved the existence of linear correlation of total facetal surface area and patellar weight, height, width, and thickness. The correlation was strongest for surface area versus patellar weight. The lateral facetal area was found persistently larger than the medial facetal area, the p value was found to be <0.001 (one-tailed t-test) for right patellae, and another significant p value of < 0.001 (one-tailed t-test) was found for left patellae. Conclusion. These data are vital for the restoration of the normal biomechanics of the patellofemoral unit; these are to be consulted during knee surgeries and implant designs and can be of an indispensable anthropometric, interethnic, and biometric value. PMID:28348891
Cytotoxicity and cellular uptake of different sized gold nanoparticles in ovarian cancer cells
NASA Astrophysics Data System (ADS)
Kumar, Dhiraj; Mutreja, Isha; Chitcholtan, Kenny; Sykes, Peter
2017-11-01
Nanomedicine has advanced the biomedical field with the availability of multifunctional nanoparticles (NPs) systems that can target a disease site enabling drug delivery and helping to monitor the disease. In this paper, we synthesised the gold nanoparticles (AuNPs) with an average size 18, 40, 60 and 80 nm, and studied the effect of nanoparticles size, concentration and incubation time on ovarian cancer cells namely, OVCAR5, OVCAR8, and SKOV3. The size measured by transmission electron microscopy images was slightly smaller than the hydrodynamic diameter; measured size by ImageJ as 14.55, 38.13, 56.88 and 78.56 nm. The cellular uptake was significantly controlled by the AuNPs size, concentration, and the cell type. The nanoparticles uptake increased with increasing concentration, and 18 and 80 nm AuNPs showed higher uptake ranging from 1.3 to 5.4 μg depending upon the concentration and cell type. The AuNPs were associated with a temporary reduction in metabolic activity, but metabolic activity remained more than 60% for all sample types; NPs significantly affected the cell proliferation activity in first 12 h. The increase in nanoparticle size and concentration induced the production of reactive oxygen species in 24 h.
Dawan, Phanphruk; Satarpai, Thiphol; Tuchinda, Patoomratana; Shiowatana, Juwadee; Siripinyanond, Atitaya
2017-01-01
A new analytical platform based on the use of thin-layer chromatography (TLC) coupled with paper-based analytical device (PAD) was developed for the determination of total capsaicinoids in chilli samples. This newly developed TLC-PAD is simple and low-cost without any requirement of special instrument or skillful person. The analysis consisted of two steps, i.e., extraction of capsaicinoids from chilli samples by using ethanol as solvent and separation of capsaicinoids by thin-layer chromatography (TLC) and elution of capsaicinoids from the TLC plate with in situ colorimetric detection of capsaicinoids on the PAD. For colorimetric detection, Folin-Ciocalteu reagent was used to detect phenolic functional group of capsaicinoids yielding the blue color. The blue color on the PAD was imaged by a scanner followed by evaluation of its grayscale intensity value by ImageJ program. This newly developed TLC-PAD method provided a linear range from 50 to 1000mgL -1 capsaicinoids with the limit of detection as low as 50mgL -1 capsaicinoids. The proposed method was applied to determine capsaicinoids in dried chilli and seasoning powder samples and the results were in good agreement with those obtained by HPLC method. Copyright © 2016 Elsevier B.V. All rights reserved.
Photo Z: A Real Research Project for Undergraduate Non-Majors
NASA Astrophysics Data System (ADS)
Rector, Travis A.; Puckett, A. W.; Hinnah, K. D.
2009-01-01
Research-Based Science Education (RBSE) is a method of instruction that models the processes of scientific inquiry and exploration used by scientists to discover new knowledge. It is "research-based" in the sense that students work together on a real astronomical research project. In other words, in order to learn science, students are given the opportunity to actually do science. We present "Photo Z," a new RBSE project wherein students search for distant galaxies using data from the NOAO Deep Wide Field Survey (NDWFS). Students download FITS data files from the NDWFS cutout server. They then complete photometry of galaxies in three bands (Bw, V and I) using Polaris, a custom-made plugin written for ImageJ. The photometric color of each galaxy allows an estimate of its redshift as well as its star-formation history. Many student projects are possible. An example is to search for galaxies clustered around high-redshift quasars. An advantage of this project is that the datasets are readily available online. This project is part of an NSF CCLI grant to develop and test RBSE curricula in an undergraduate course setting. The goals of RBSE are fourfold: (1) To teach that science is a process, not just a body of knowledge; (2) To improve retention of science content by using it in a research project; (3) to improve attitudes towards STEM careers, particularly among first-year students; and (4) to develop task-driven skills, such as critical thinking and teamwork skills, that are useful in any career path. These curricula are currently being developed and tested at the University of Alaska Anchorage, Indiana University Bloomington, and Pima Community College.
Demirturk Kocasarac, Husniye; Helvacioglu Yigit, Dilek; Bechara, Boulos; Sinanoglu, Alper; Noujeim, Marcel
2016-01-01
To compare the contrast-to-noise ratio (CNR) of multiple acquisition settings for four types of retrograde filling materials in CBCT images taken for endodontic surgery follow-up. 20 maxillary central incisors were endodontically treated and obturated with 4 different root-end filling materials: amalgam, mineral trioxide aggregate, SuperEBA(™) (Harry J Bosworth Company, Skokie, IL) and Biodentine™ (Septodont, Saint-Maur-des-Faussés, France). Teeth were placed in a skull and scanned, one by one, with the Planmeca ProMax(®) 3D Max (Planmeca, Helsinki, Finland); at different voltages: 66, 76, 84 and 96 kVp; with low, normal and high resolution and high definition (HD); with and without metal artefact reduction (MAR). Images were analyzed using ImageJ software (National Institutes of Health, Bethesda, MD) to calculate the CNR. The dose-area product was registered, and the effective dose calculated. No statistically significant difference was noted between the four materials. 84 and 96 kVp with low resolution and the use of MAR-generated images that have statistically better CNR than 66 and 76 kVp with HD, normal and high resolutions and without MAR. The use of low resolution also generated the smallest value of effective dose. The best setting for radiographic follow-up in an endodontic surgery with retrograde filling on the Planmeca ProMax is 96 kVp with low resolution and high MAR; this setting produced one of the lowest effective doses.
Optimal time following fluorescein instillation to evaluate rigid gas permeable contact lens fit.
Wolffsohn, James S; Tharoo, Ali; Lakhlani, Nikita
2015-04-01
To examine the optimum time at which fluorescein patterns of gas permeable lenses (GPs) should be evaluated. Aligned, 0.2mm steep and 0.2mm flat GPs were fitted to 17 patients (aged 20.6 ± 1.1 years, 10 male). Fluorescein was applied to their upper temporal bulbar conjunctiva with a moistened fluorescein strip. Digital slit lamp images (CSO, Italy) at 10× magnification of the fluorescein pattern viewed with blue light through a yellow filter were captured every 15s. Fluorescein intensity in central, mid peripheral and edge regions of the superior, inferior, temporal and nasal quadrants of the lens were graded subjectively using a +2 to -2 scale and using ImageJ software on the simultaneously captured images. Subjectively graded and objectively image analysed fluorescein intensity changed with time (p < 0.001), lens region (centre, mid-periphery and edge: p < 0.05) and there was interaction between lens region with lens fit (p < 0.001). For edge band width, there was a significant effect of time (F = 118.503, p < 0.001) and lens fit (F = 5.1249, p = 0.012). The expected alignment, flat and steep fitting patterns could be seen from approximately after 30 to 180 s subjectively and 15 to 105 s in captured images. Although the stability of fluorescein intensity can start to decline in as little as 45 s post fluorescein instillation, the diagnostic pattern of alignment, steep or flat fit is seen in each meridian by subjective observation from about 30s to 3 min indicating this is the most appropriate time window to evaluate GP lenses in clinical practice. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
A novel measure and significance testing in data analysis of cell image segmentation.
Wu, Jin Chu; Halter, Michael; Kacker, Raghu N; Elliott, John T; Plant, Anne L
2017-03-14
Cell image segmentation (CIS) is an essential part of quantitative imaging of biological cells. Designing a performance measure and conducting significance testing are critical for evaluating and comparing the CIS algorithms for image-based cell assays in cytometry. Many measures and methods have been proposed and implemented to evaluate segmentation methods. However, computing the standard errors (SE) of the measures and their correlation coefficient is not described, and thus the statistical significance of performance differences between CIS algorithms cannot be assessed. We propose the total error rate (TER), a novel performance measure for segmenting all cells in the supervised evaluation. The TER statistically aggregates all misclassification error rates (MER) by taking cell sizes as weights. The MERs are for segmenting each single cell in the population. The TER is fully supported by the pairwise comparisons of MERs using 106 manually segmented ground-truth cells with different sizes and seven CIS algorithms taken from ImageJ. Further, the SE and 95% confidence interval (CI) of TER are computed based on the SE of MER that is calculated using the bootstrap method. An algorithm for computing the correlation coefficient of TERs between two CIS algorithms is also provided. Hence, the 95% CI error bars can be used to classify CIS algorithms. The SEs of TERs and their correlation coefficient can be employed to conduct the hypothesis testing, while the CIs overlap, to determine the statistical significance of the performance differences between CIS algorithms. A novel measure TER of CIS is proposed. The TER's SEs and correlation coefficient are computed. Thereafter, CIS algorithms can be evaluated and compared statistically by conducting the significance testing.
Erdal, Barbaros Selnur; Yildiz, Vedat; King, Mark A.; Patterson, Andrew T.; Knopp, Michael V.; Clymer, Bradley D.
2012-01-01
Background: Chest CT scans are commonly used to clinically assess disease severity in patients presenting with pulmonary sarcoidosis. Despite their ability to reliably detect subtle changes in lung disease, the utility of chest CT scans for guiding therapy is limited by the fact that image interpretation by radiologists is qualitative and highly variable. We sought to create a computerized CT image analysis tool that would provide quantitative and clinically relevant information. Methods: We established that a two-point correlation analysis approach reduced the background signal attendant to normal lung structures, such as blood vessels, airways, and lymphatics while highlighting diseased tissue. This approach was applied to multiple lung fields to generate an overall lung texture score (LTS) representing the quantity of diseased lung parenchyma. Using deidentified lung CT scan and pulmonary function test (PFT) data from The Ohio State University Medical Center’s Information Warehouse, we analyzed 71 consecutive CT scans from patients with sarcoidosis for whom simultaneous matching PFTs were available to determine whether the LTS correlated with standard PFT results. Results: We found a high correlation between LTS and FVC, total lung capacity, and diffusing capacity of the lung for carbon monoxide (P < .0001 for all comparisons). Moreover, LTS was equivalent to PFTs for the detection of active lung disease. The image analysis protocol was conducted quickly (< 1 min per study) on a standard laptop computer connected to a publicly available National Institutes of Health ImageJ toolkit. Conclusions: The two-point image analysis tool is highly practical and appears to reliably assess lung disease severity. We predict that this tool will be useful for clinical and research applications. PMID:22628487
Optical edge effects create conjunctival indentation thickness artefacts.
Sorbara, Luigina; Simpson, Trefford L; Maram, Jyotsna; Song, Eun Sun; Bizheva, Kostadinka; Hutchings, Natalie
2015-05-01
Conjunctival compression observed in ultrahigh resolution optical coherence tomography (UHR-OCT) images of contact lens edges could be actual tissue alteration, may be an optical artefact arising from the difference between the refractive indexes of the lens material and the conjunctival tissue, or could be a combination of the two. The purpose of this study is to image the artefact with contact lenses on a non-biological (non-indentable) medium and to determine the origins of the observed conjunctival compression. Two-dimensional cross-sectional images of the edges of a selection of marketed silicone hydrogel and hydrogel lenses (refractive index ranging from 1.40 to 1.43) were acquired with a research grade UHR-OCT system. The lenses were placed on three continuous surfaces, a glass sphere (refractive index n = 1.52), a rigid contact lens (n = 1.376) and the cornea of a healthy human subject (average n = 1.376). The displacement observed was analysed using ImageJ. The observed optical displacement ranged between 5.39(0.06) μm with Acuvue Advance and 11.99(0.18) μm with Air Optix Night & Day when the lens was imaged on the glass reference sphere. Similarly, on a rigid contact lens displacement ranged between 5.51(0.03) and 9.72(0.12) μm. Displacement was also observed when the lenses were imaged on the human conjunctiva and ranged from 6.49(0.80) μm for the 1-day Acuvue Moist to 17.4(0.22) μm for the Pure Vision contact lens. An optical displacement artefact was observed when imaging a contact lens on two rigid continuous surfaces with UHR-OCT where compression or indentation of the surface could not have been a factor. Contact lenses imaged in situ also exhibited displacement at the intersection of the contact lens edge and the conjunctiva, likely a manifestation of both the artefact and compression of the conjunctiva. © 2015 The Authors Ophthalmic & Physiological Optics © 2015 The College of Optometrists.
Detection of kinetic change points in piece-wise linear single molecule motion
NASA Astrophysics Data System (ADS)
Hill, Flynn R.; van Oijen, Antoine M.; Duderstadt, Karl E.
2018-03-01
Single-molecule approaches present a powerful way to obtain detailed kinetic information at the molecular level. However, the identification of small rate changes is often hindered by the considerable noise present in such single-molecule kinetic data. We present a general method to detect such kinetic change points in trajectories of motion of processive single molecules having Gaussian noise, with a minimum number of parameters and without the need of an assumed kinetic model beyond piece-wise linearity of motion. Kinetic change points are detected using a likelihood ratio test in which the probability of no change is compared to the probability of a change occurring, given the experimental noise. A predetermined confidence interval minimizes the occurrence of false detections. Applying the method recursively to all sub-regions of a single molecule trajectory ensures that all kinetic change points are located. The algorithm presented allows rigorous and quantitative determination of kinetic change points in noisy single molecule observations without the need for filtering or binning, which reduce temporal resolution and obscure dynamics. The statistical framework for the approach and implementation details are discussed. The detection power of the algorithm is assessed using simulations with both single kinetic changes and multiple kinetic changes that typically arise in observations of single-molecule DNA-replication reactions. Implementations of the algorithm are provided in ImageJ plugin format written in Java and in the Julia language for numeric computing, with accompanying Jupyter Notebooks to allow reproduction of the analysis presented here.
A new method for computer-assisted detection, definition and differentiation of the urinary calculi.
Yildirim, Duzgun; Ozturk, Ovunc; Tutar, Onur; Nurili, Fuad; Bozkurt, Halil; Kayadibi, Huseyin; Karaarslan, Ercan; Bakan, Selim
2014-09-01
Urinary stones are common and can be diagnosed with computed tomography (CT) easily. In this study, we aimed to specify the opacity characteristics of various types of calcified foci that develop through the urinary system by using an image analysis program. With this method, we try to differentiate the calculi from the non-calculous opacities and also we aimed to present how to identify the characteristic features of renal and ureteral calcules. We obtained the CT studies of the subjects (n = 48, mean age = 41 years) by using a dual source CT imaging system. We grouped the calculi detected in the dual-energy CT sections as renal (n = 40) or ureteric (n = 45) based on their locations. Other radio-opaque structures that were identified outside but within close proximity of the urinary tract were recorded as calculi "mimickers". We used ImageJ program for morphological analysis. All the acquired data were analyzed statistically. According to thorough morphological parameters, there were statistically significant differences in the angle and Feret angle values between calculi and mimickers (p < 0.001). Multivariate logistical regression analysis showed that Minor Axis and Feret angle parameters can be used to distinguish between ureteric (p = 0.003) and kidney (p = 0.001) stones. Computer-based morphologic parameters can be used simply to differentiate between calcular and noncalcular densities on CT and also between renal and ureteric stones.
Puchkov, Evgeny O
2010-06-01
In the vacuoles of Saccharomyces cerevisiae yeast cells, vividly moving insoluble polyphosphate complexes (IPCs) <1 microm size, stainable by a fluorescent dye, 4',6-diamidino-2-phenylindole (DAPI), may appear under some growth conditions. The aim of this study was to quantitatively characterize the movement of the IPCs and to evaluate the viscosity in the vacuoles using the obtained data. Studies were conducted on S. cerevisiae cells stained by DAPI and fluorescein isothyocyanate-labelled latex microspheres, using fluorescence microscopy combined with computer image analysis (ImageJ software, NIH, USA). IPC movement was photorecorded and shown to be Brownian motion. On latex microspheres, a methodology was developed for measuring a fluorescing particle's two-dimensional (2D) displacements and its size. In four yeast cells, the 2D displacements and sizes of the IPCs were evaluated. Apparent viscosity values in the vacuoles of the cells, computed by the Einstein-Smoluchowski equation using the obtained data, were found to be 2.16 +/- 0.60, 2.52 +/- 0.63, 3.32 +/- 0.9 and 11.3 +/- 1.7 cP. The first three viscosity values correspond to 30-40% glycerol solutions. The viscosity value of 11.3 +/- 1.7 cP was supposed to be an overestimation, caused by the peculiarities of the vacuole structure and/or volume in this particular cell. This conclusion was supported by the particular quality of the Brownian motion trajectories set in this cell as compared to the other three cells.
Costa, Carla; Vendeira, Pedro
2008-04-01
Introduction. Erectile dysfunction is a common problem in aged men; however, which vascular cavernosal alterations occur with age progression remain unclarified. Aim. Using cavernosal tissue from rats of various ages, we aimed to thoroughly assess erectile vascular-associated morphologic, immunohistological, and morphometric alterations during aging. Methods. Male Wistar rats were divided according to age in groups of 2, 6, 12, 18, 24 months old (N = 5). Cavernosal tissue of all groups was collected and processed for morphologic evaluation, immunodetection of alpha-smooth muscle actin and von Willebrand factor and morphometric quantification of vascular and smooth muscle cell (SMC) areas. Main Outcome Measures. The morphometric assessment of age-related alterations in cavernosal vascular and SMCs using the ImageJ image-processing program. Results. Morphologic and immunohistological evaluation showed a similar structure of erectile tissue among all age groups, divided in two cavernosal bodies containing numerous sinusoidal vascular spaces surrounded by SMCs. Additionally, we observed a reduction of SMC content and an increase in the caliber of vascular spaces, with aging. This was confirmed by the morphometric quantification of the vascular and SMC areas (mean area x10(3) microm(2) +/- x10(3) standard error). Two-month-old animals had a mean vascular area of 4.21 +/- 0.51, approximately 3.5-fold less than the 6-month-old group. The differences increased when comparing the youngest groups with the 12-, 18-, and 24-month-old animals, with mean measurements of 18.99 +/- 1.91, 25.23 +/- 2.76, and 26.34 +/- 2.97. Conversely, SMC areas progressively decreased between 2- and 6-month-old animals, from 6.75 +/- 0.90 to 6.38 +/- 1.24. The elderly 12-, 18-, and 24-month-old groups presented an approximated 1.5-fold reduction on SMCs area, showed by the respective measurements of 4.11 +/- 0.50, 4.01 +/- 0.35, and 4.02 +/- 0.44. Conclusions. We demonstrated that cavernosal angioarchitecture was modified with aging. The decrease in SMCs and the considerable enlargement of vascular lumens may limit the basic function of penile vascular tree in the elderly.
Monitoring diver kinematics with dielectric elastomer sensors
NASA Astrophysics Data System (ADS)
Walker, Christopher R.; Anderson, Iain A.
2017-04-01
Diving, initially motivated for food purposes, is crucial to the oil and gas industry, search and rescue, and is even done recreationally by millions of people. There is a growing need however, to monitor the health and activity of divers. The Divers Alert Network has reported on average 90 fatalities per year since 1980. Furthermore an estimated 1000 divers require recompression treatment for dive-related injuries every year. One means of monitoring diver activity is to integrate strain sensors into a wetsuit. This would provide kinematic information on the diver potentially improving buoyancy control assessment, providing a platform for gesture communication, detecting panic attacks and monitoring diver fatigue. To explore diver kinematic monitoring we have coupled dielectric elastomer sensors to a wetsuit worn by the pilot of a human-powered wet submarine. This provided a unique platform to test the performance and accuracy of dielectric elastomer strain sensors in an underwater application. The aim of this study was to assess the ability of strain sensors to monitor the kinematics of a diver. This study was in collaboration with the University of Auckland's human-powered submarine team, Team Taniwha. The pilot, completely encapsulated in a hull, pedals to propel the submarine forward. Therefore this study focused on leg motion as that is the primary motion of the submarine pilot. Four carbon-filled silicone dielectric elastomer sensors were fabricated and coupled to the pilot's wetsuit. The first two sensors were attached over the knee joints, with the remaining two attached between the pelvis and thigh. The goal was to accurately measure leg joint angles thereby determining the position of each leg relative to the hip. A floating data acquisition unit monitored the sensors and transmitted data packets to a nearby computer for real-time processing. A GoPro Hero 4 silver edition was used to capture the experiments and provide a means of post-validation. The ability of the sensors to measure joint angles was assessed by examining GoPro footage in the image processing software, ImageJ. This paper applies dielectric elastomer sensor technology to monitoring the leg motion of a diver. The experimental set-up and results are presented and discussed.
Fungal mycelia in soils - a new method for quantification of their biomass
NASA Astrophysics Data System (ADS)
Drabløs Eldhuset, Toril; Lange, Holger; Svetlik, Jan; Børja, Isabella
2013-04-01
All plant-bearing soils are interwoven with fungal hyphae. Their structure and function are affected by environmental factors like drought, which might be a stress factor of increasing importance in many world regions due to climate change. The fungal mycelium in soil is important both for mycorrhizal symbiosis with plant roots and for litter decomposition, and thereby also for carbon turnover in soils. However, the mycelium biomass has been difficult to assess. Here we describe a simple and feasible method to quantify the biomass of fungal mycelium. We report on a manipulation study in the field where drought stress has been induced. The experiment was performed in a Norway spruce (Picea abies) 20 years old stand planted on former agricultural land, with a control plot and a roofed plot where precipitation was excluded. To investigate the fungal mycelium, nylon nets (mesh size 1 mm, width 7 cm and length 25 cm), were inserted vertically into the soil down to 20 cm depth. The nets were left in the soil from October to June, removed and replaced by new nets that were left in the soil from June to October. After removal, by cutting a block of soil around each net, the nets were cleaned from residual soil and scanned using the image scanner CanoScan 9000F. The resulting images were analyzed using the image processing software ImageJ. The image analysis was based on the distribution of grey values in the individual pixels which characterize the different components in the image (voids, hyphae, the nylon net, and soil). Based on the repeated visual evaluation of hyphal coverage in the net segments, we obtained an exponential equation allowing us to determine automatically the coverage of net windows by hyphae in percentage for each net scanned. In this way we can compare the hyphal coverage in the control and the drought-exposed plots. Based on the hyphal coverage scans together with hyphal dry weight on clean nets, we account for the soil particles adhering to the nets. Using this analysis method, the hyphal mat coverage in mm2 on any net is quantified and the hyphal biomass on the net can be calculated and compared between treatments. Also, the hyphal biomass per cm3 soil at the spot where the net has been inserted can be assessed. In addition, DNA from net-bound hyphae may be extracted to determine the identity of fungal species at different soil depths for the individual treatments.
Evolution of Fractal Parameters through Development Stage of Soil Crust
NASA Astrophysics Data System (ADS)
Ospina, Abelardo; Florentino, Adriana; Tarquis, Ana Maria
2016-04-01
Soil surface characteristics are subjected to changes driven by several interactions between water, air, biotic and abiotic components. One of the examples of such interactions is provided through biological soil crusts (BSC) in arid and semi-arid environments. BSC are communities composed of cyanobacteria, fungi, mosses, lichens, algae and liverworts covering the soil surface and play an important role in ecosystem functioning. The characteristics and formation of these BSC influence the soil hydrological balance, control the mass of eroded sediment, increase stability of soil surface, and influence plant productivity through the modification of nitrogen and carbon cycle. The site of this work is located at Quibor and Ojo de Agua (Lara state, Venezuela). The Quibor Depression in Venezuela is a major agricultural area being at semi-arid conditions and limited drainage favor the natural process of salinization. Additionally, the extension and intensification of agriculture has led to over-exploitation of groundwater in the past 30 years (Méndoza et al., 2013). The soil microbial crust develops initially on physical crusts which are mainly generated since wetting and drying, being a recurrent feature in the Quíbor arid zone. The microbiotic crust is organic, composed of macro organisms (bryophytes and lichens) and microorganisms (cyanobacteria, fungi algae, etc.); growing on the ground, forming a thickness no greater than 3 mm. For further details see Toledo and Florentino (2009). This study focus on characterize the development stage of the BSC based on image analysis. To this end, grayscale images of different types of biological soil crust at different stages where taken, each image corresponding to an area of 12.96 cm2 with a resolution of 1024x1024 pixels (Ospina et al., 2015). For each image lacunarity and fractal dimension through the differential box counting method were calculated. These were made with the software ImageJ/Fraclac (Karperien, 2013). REFERENCES Karperien, A. (2013). FracLac for ImageJ. Méndoza, B., Florentino, A., Hernández-Hernández, R.M., Aciego, J., Torres, D. and Vera, Elena. (2013). Biological attributes of two Quibor soils with addition of organic fertilizer and salt solutions. Revista Mexicana de Ciencias Agrícolas, 4(3), 409-421. Ospina, Abelardo, Adriana Florentino and Ana M. Tarquis (2015) Spatial Pattern of Biological Soil Crust with Fractal Geometry. Geophysical Research Abstracts, 17, EGU2015-15415-1 Toledo, V. and Florentino, A. (2009). The Microbiotic Crust On Soil. Revista de Investigación N° 68(33), 199-216.
Seeing the Soils of Meridiani Planum Through the Eyes of Pancam and Microscopic Imager
NASA Technical Reports Server (NTRS)
Weitz, C. M.; Anderson, R. C.; Bell, J. F., III; Cabrol, N. A.; Calvin, W. M.; Ehlmann, B. L.; Farrand, W. H.; Greeley, R.; Herkenhoff, K. E.; Johnson, J. R.
2005-01-01
We are using data from the Pancam and Microscopic Imager (MI) on the Opportunity rover to characterize the soil grains at Meridiani Planum. We have traced individual grains in all MI images of the soils using the software application ImageJ distributed by NIH, and subsequently derived size and shape properties about the grains. The resolution of the MI is 31 microns per pixel [1] so we limit our measurements to those grains larger than about 0.3 mm in size. In cases where the grain is partially or substantially buried by other grains or finer soil particles, we do not make a measurement. False-color composites from Pancam images that cover the same location imaged by MI are made from the Left 2,5,6 (753, 535, 482 nm) filters or Right 2,7,1 (753, 1009, 430 nm) filters [2] in the Red, Green, and Blue channels, respectively. These color images are then merged with the MI images to illustrate color properties of particular grains. Pancam spectra are also extracted from grains when there is sufficient spatial coverage. in diameter. Figure 2 illustrates the dominance of these small grains at this particular location, which happens to be on the southern wall of Eagle crater. The Pancam color merge with this MI image suggests that the small spherules are more consistent with the basalt grains than the blueberries (spherulitic concretions derived from outcrop rocks [7]). The resolution of Pancam images of this location is on the order of 0.5 mm so the grains are only barely resolved. A Mossbauer measurement taken on an adjacent soil (Sol 53 Vanilla) that is composed solely of these smaller spherules (Fig 1) is consistent with a basaltic composition for the grains. Their concentration at this particular location in a brighter, elongate patch along the southeastern wall compared to elsewhere inside Eagle crater suggests wind activity favored their transport and subsequent deposition here. Their spherical shape is also possibly the result of wind action rounding them during transport, though water action cannot be ruled out.
Perez-Garcia, H; Barquero, R
The correct determination and delineation of tumor/organ size is crucial in 2-D imaging in 131 I therapy. These images are usually obtained using a system composed of a Gamma camera and high-energy collimator, although the system can produce artifacts in the image. This article analyses these artifacts and describes a correction filter that can eliminate those collimator artifacts. Using free software, ImageJ, a central profile in the image is obtained and analyzed. Two components can be seen in the fluctuation of the profile: one associated with the stochastic nature of the radiation, plus electronic noise and the other periodically across the position in space due to the collimator. These frequencies are analytically obtained and compared with the frequencies in the Fourier transform of the profile. A specially developed filter removes the artifacts in the 2D Fourier transform of the DICOM image. This filter is tested using a 15-cm-diameter Petri dish with 131 I radioactive water (big object size) image, a 131 I clinical pill (small object size) image, and an image of the remainder of the lesion of two patients treated with 3.7GBq (100mCi), and 4.44GBq (120mCi) of 131 I, respectively, after thyroidectomy. The artifact is due to the hexagonal periodic structure of the collimator. The use of the filter on large-sized images reduces the fluctuation by 5.8-3.5%. In small-sized images, the FWHM can be determined in the filtered image, while this is impossible in the unfiltered image. The definition of tumor boundary and the visualization of the activity distribution inside patient lesions improve drastically when the filter is applied to the corresponding images obtained with HE gamma camera. The HURRA filter removes the artifact of high-energy collimator artifacts in planar images obtained with a Gamma camera without reducing the image resolution. It can be applied in any study of patient quantification because the number of counts remains invariant. The filter makes possible the definition and delimitation of small uptakes, such as those presented in treatments with 131 I. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.
Robinson, Alan M; Stock, Stuart R; Soriano, Carmen; Xiao, Xianghui; Richter, Claus-Peter
2016-11-01
The aim of this study was to determine if X-ray micro-computed tomography could be used to locate and characterize tissue damage caused by laser irradiation and to describe its advantages over classical histology for this application. A surgical CO 2 laser, operated in single pulse mode (100 milliseconds) at different power settings, was used to ablate different types of cadaveric animal tissues. Tissue samples were then harvested and imaged with synchrotron X-ray phase-contrast and micro-computed tomography to generate stacks of virtual sections of the tissues. Subsequently, Fiji (ImageJ) software was used to locate tissue damage, then to quantify volumes of laser ablation cones and thermal coagulation damage from 3D renderings of tissue image stacks. Visual comparisons of tissue structures in X-ray images with those visible by classic light microscopy histology were made. We demonstrated that micro-computed tomography could be used to rapidly identify areas of surgical laser ablation, vacuolization, carbonization, and thermally coagulated tissue. Quantification and comparison of the ablation crater, which represents the volume of ablated tissue, and the thermal coagulation zone volumes were performed faster than we could by classical histology. We demonstrated that these procedures can be performed on fresh hydrated and non-sectioned plastic embedded tissue. We demonstrated that the application of non-destructive micro-computed tomography to the visualization and analysis of laser induced tissue damage without tissue sectioning is possible. This will improve evaluation of new surgical lasers and their corresponding effect on tissues. Lasers Surg. Med. 48:866-877, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
A step-wise approach for analysis of the mouse embryonic heart using 17.6 Tesla MRI
Gabbay-Benziv, Rinat; Reece, E. Albert; Wang, Fang; Bar-Shir, Amnon; Harman, Chris; Turan, Ozhan M.; Yang, Peixin; Turan, Sifa
2018-01-01
Background The mouse embryo is ideal for studying human cardiac development. However, laboratory discoveries do not easily translate into clinical findings partially because of histological diagnostic techniques that induce artifacts and lack standardization. Aim To present a step-wise approach using 17.6 T MRI, for evaluation of mice embryonic heart and accurate identification of congenital heart defects. Subjects 17.5-embryonic days embryos from low-risk (non-diabetic) and high-risk (diabetic) model dams. Study design Embryos were imaged using 17.6 Tesla MRI. Three-dimensional volumes were analyzed using ImageJ software. Outcome measures Embryonic hearts were evaluated utilizing anatomic landmarks to locate the four-chamber view, the left- and right-outflow tracts, and the arrangement of the great arteries. Inter- and intra-observer agreement were calculated using kappa scores by comparing two researchers’ evaluations independently analyzing all hearts, blinded to the model, on three different, timed occasions. Each evaluated 16 imaging volumes of 16 embryos: 4 embryos from normal dams, and 12 embryos from diabetic dams. Results Inter-observer agreement and reproducibility were 0.779 (95% CI 0.653–0.905) and 0.763 (95% CI 0.605–0.921), respectively. Embryonic hearts were structurally normal in 4/4 and 7/12 embryos from normal and diabetic dams, respectively. Five embryos from diabetic dams had defects: ventricular septal defects (n = 2), transposition of great arteries (n = 2) and Tetralogy of Fallot (n = 1). Both researchers identified all cardiac lesions. Conclusion A step-wise approach for analysis of MRI-derived 3D imaging provides reproducible detailed cardiac evaluation of normal and abnormal mice embryonic hearts. This approach can accurately reveal cardiac structure and, thus, increases the yield of animal model in congenital heart defect research. PMID:27569369
Hong, Sun Suk; Lee, Jong-Woong; Seo, Jeong Beom; Jung, Jae-Eun; Choi, Jiwon; Kweon, Dae Cheol
2013-12-01
The purpose of this research is to determine the adaptive statistical iterative reconstruction (ASIR) level that enables optimal image quality and dose reduction in the chest computed tomography (CT) protocol with ASIR. A chest phantom with 0-50 % ASIR levels was scanned and then noise power spectrum (NPS), signal and noise and the degree of distortion of peak signal-to-noise ratio (PSNR) and the root-mean-square error (RMSE) were measured. In addition, the objectivity of the experiment was measured using the American College of Radiology (ACR) phantom. Moreover, on a qualitative basis, five lesions' resolution, latitude and distortion degree of chest phantom and their compiled statistics were evaluated. The NPS value decreased as the frequency increased. The lowest noise and deviation were at the 20 % ASIR level, mean 126.15 ± 22.21. As a result of the degree of distortion, signal-to-noise ratio and PSNR at 20 % ASIR level were at the highest value as 31.0 and 41.52. However, maximum absolute error and RMSE showed the lowest deviation value as 11.2 and 16. In the ACR phantom study, all ASIR levels were within acceptable allowance of guidelines. The 20 % ASIR level performed best in qualitative evaluation at five lesions of chest phantom as resolution score 4.3, latitude 3.47 and the degree of distortion 4.25. The 20 % ASIR level was proved to be the best in all experiments, noise, distortion evaluation using ImageJ and qualitative evaluation of five lesions of a chest phantom. Therefore, optimal images as well as reduce radiation dose would be acquired when 20 % ASIR level in thoracic CT is applied.
Welsch, Goetz H; Laqmani, Azien; Henes, Frank O; Kaul, Michael G; Schoen, Gerhard; Adam, Gerhard; Regier, Marc
2016-01-01
Objective: To quantitatively assess the immediate effect of long-distance running on T2 and T2* relaxation times of the articular cartilage of the knee at 3.0 T in young healthy adults. Methods: 30 healthy male adults (18–31 years) who perform sports at an amateur level underwent an initial MRI at 3.0 T with T2 weighted [16 echo times (TEs): 9.7–154.6 ms] and T2* weighted (24 TEs: 4.6–53.6 ms) relaxation measurements. Thereafter, all participants performed a 45-min run. After the run, all individuals were immediately re-examined. Data sets were post-processed using dedicated software (ImageJ; National Institute of Health, Bethesda, MD). 22 regions of interest were manually drawn in segmented areas of the femoral, tibial and patellar cartilage. For statistical evaluation, Pearson product–moment correlation coefficients and confidence intervals were computed. Results: Mean initial values were 35.7 ms for T2 and 25.1 ms for T2*. After the run, a significant decrease in the mean T2 and T2* relaxation times was observed for all segments in all participants. A mean decrease of relaxation time was observed for T2 with 4.6 ms (±3.6 ms) and for T2* with 3.6 ms (±5.1 ms) after running. Conclusion: A significant decrease could be observed in all cartilage segments for both biomarkers. Both quantitative techniques, T2 and T2*, seem to be valuable parameters in the evaluation of immediate changes in the cartilage ultrastructure after running. Advances in knowledge: This is the first direct comparison of immediate changes in T2 and T2* relaxation times after running in healthy adults. PMID:27336705
Behzadi, Cyrus; Welsch, Goetz H; Laqmani, Azien; Henes, Frank O; Kaul, Michael G; Schoen, Gerhard; Adam, Gerhard; Regier, Marc
2016-08-01
To quantitatively assess the immediate effect of long-distance running on T2 and T2* relaxation times of the articular cartilage of the knee at 3.0 T in young healthy adults. 30 healthy male adults (18-31 years) who perform sports at an amateur level underwent an initial MRI at 3.0 T with T2 weighted [16 echo times (TEs): 9.7-154.6 ms] and T2* weighted (24 TEs: 4.6-53.6 ms) relaxation measurements. Thereafter, all participants performed a 45-min run. After the run, all individuals were immediately re-examined. Data sets were post-processed using dedicated software (ImageJ; National Institute of Health, Bethesda, MD). 22 regions of interest were manually drawn in segmented areas of the femoral, tibial and patellar cartilage. For statistical evaluation, Pearson product-moment correlation coefficients and confidence intervals were computed. Mean initial values were 35.7 ms for T2 and 25.1 ms for T2*. After the run, a significant decrease in the mean T2 and T2* relaxation times was observed for all segments in all participants. A mean decrease of relaxation time was observed for T2 with 4.6 ms (±3.6 ms) and for T2* with 3.6 ms (±5.1 ms) after running. A significant decrease could be observed in all cartilage segments for both biomarkers. Both quantitative techniques, T2 and T2*, seem to be valuable parameters in the evaluation of immediate changes in the cartilage ultrastructure after running. This is the first direct comparison of immediate changes in T2 and T2* relaxation times after running in healthy adults.
Pennekamp, Frank; Schtickzelle, Nicolas; Petchey, Owen L
2015-07-01
Microbes are critical components of ecosystems and provide vital services (e.g., photosynthesis, decomposition, nutrient recycling). From the diverse roles microbes play in natural ecosystems, high levels of functional diversity result. Quantifying this diversity is challenging, because it is weakly associated with morphological differentiation. In addition, the small size of microbes hinders morphological and behavioral measurements at the individual level, as well as interactions between individuals. Advances in microbial community genetics and genomics, flow cytometry and digital analysis of still images are promising approaches. They miss out, however, on a very important aspect of populations and communities: the behavior of individuals. Video analysis complements these methods by providing in addition to abundance and trait measurements, detailed behavioral information, capturing dynamic processes such as movement, and hence has the potential to describe the interactions between individuals. We introduce BEMOVI, a package using the R and ImageJ software, to extract abundance, morphology, and movement data for tens to thousands of individuals in a video. Through a set of functions BEMOVI identifies individuals present in a video, reconstructs their movement trajectories through space and time, and merges this information into a single database. BEMOVI is a modular set of functions, which can be customized to allow for peculiarities of the videos to be analyzed, in terms of organisms features (e.g., morphology or movement) and how they can be distinguished from the background. We illustrate the validity and accuracy of the method with an example on experimental multispecies communities of aquatic protists. We show high correspondence between manual and automatic counts and illustrate how simultaneous time series of abundance, morphology, and behavior are obtained from BEMOVI. We further demonstrate how the trait data can be used with machine learning to automatically classify individuals into species and that information on movement behavior improves the predictive ability.
Serkies, Kyle B; Garcha, Reena; Tam, Laura E; De Souza, Grace M; Finer, Yoav
2016-12-01
Assess the modulating effect of matrix metalloproteinase (MMP) inhibition on simulated human salivary enzyme (SHSE)-catalyzed degradation of interfacial fracture-toughness (FT) of self-etched and total-etched resin-dentin interfaces. Miniature short-rod FT specimens (N=10/group) containing a resin composite bonded to human dentin, using a self-etch (Easy Bond, EB) or a total-etch (Scotchbond, SB) adhesives, were prepared with and without application of an MMP inhibitor (galardin). Specimens were non-incubated or incubated in phosphate buffered saline (PBS) or SHSE for 7, 30, 90, or 180-days. FT data were obtained using a universal testing machine. Incubation media were analyzed by high performance liquid chromatography (HPLC) for the presence of a 2,2-bis-[4-2(2-hydroxy-3-methacryloxypropoxy)phenyl]-propane (bisGMA)-derived degradation product, bis-hydroxy-propoxy-phenyl-propane (bisHPPP). Fractographic analysis was performed by scanning electron microscopy and image processing software (ImageJ). Statistical analysis was performed by ANOVA and Tukey's (p<0.05). More bisHPPP was detected in SHSE vs. PBS for both adhesive systems (p<0.05). EB specimens yielded no difference in FT and failed preferentially in the resin after >30-days (p<0.05). SB specimens yielded lower FT values after 180-days with SHSE ±galardin vs. 0-days/no-galardin (p<0.05) and failed preferentially in the hybrid-layer after >30-days (p<0.05). Galardin mildly modulated the change in fracture mode for both systems. Esterase-catalyzed degradation of total-etch interfaces is modulated by MMP-inhibition, however, self-etch interfaces possess greater biostability under simulated intra-oral conditions, regardless of MMP inhibition. This could be related to different chemical compositions and/or mode of adhesion. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Development and performance evaluation of air fine bubbles on water quality of thai catfish rearing
NASA Astrophysics Data System (ADS)
Subhan, Ujang; Muthukannan, Vanitha; Azhary, Sundoro Yoga; Mulhadi, Muhammad Fakhri; Rochima, Emma; Panatarani, Camellia; Joni, I. Made
2018-02-01
The efficiency and productivity of aquaculture strongly depends on the development of advanced technology for water quality management system. The most important factor for the success of intensive aquaculture system is controlling the water quality of fish rearing media. This paper reports the design of fine bubbles (FBs) generator and performance evaluation of the system to improve water quality in thai catfish media (10 g/ind) with density (16.66 ind./L). The FBs generator was designed to control the size distribution of bubble by controlling its air flow rate entry to the mixing chamber of the generator. The performance of the system was evaluated based on the produced debit, dissolved oxygen rate and ammonia content in the catfish medium. The size distribution was observed by using a high speed camera image followed by processing using ImageJ. freeware application. The results show that air flow rate 0.05 L/min and 0.1 L/min received average bubble size of 29 µm and 31 µm respectively. The generator produced bubbles with capacity of 6 L/min and dissolved oxygen rate 0.2 ppm/min/L. The obtained DO growth was 0.455 ppm/second/L while the average decay rate was 0.20 ppm/second/L. (0.011/0.005 fold). In contrast, the recieved DO growth rate is faster compared to the DO consumption rate of the Thai catfish. This results indicated that the potential application of FBs enhanced the density of thai catfish seed rearing. In addition, ammonia can be reduced at 0.0358 ppm/hour/L and it is also observed that the inhibition of bacterial growth of air FBs is postive to Aeromonas hydrophila bacteria compared to the negative control. It is concluded that as-developed FBs system can be potentially applied for intensive thai catfish culture and expected to improve the feeding efficiency rate.
Lower energy and pulse stacking. A safer alternative for skin tightening using fractional CO2 laser.
Motta, Marcos Matias; Stelini, Rafael Fantelli; Calderoni, Davi Reis; Gilioli, Rovilson; Kharmandayan, Paulo
2016-01-01
To evaluate the effect of different energies and stacking in skin shrinkage. Three decreasing settings of a fractional CO2 laser were applied to the abdomen of Twenty five Wistar rats divided into three groups. Group I (n=5) was histologically evaluated for microthermal zones dimensions. Groups II and III (n=10 each) were macroscopic evaluated with freeware ImageJ for area contraction immediately and after 30 and 60 days. No statistical significance was found within microthermal zone histological dimensions (Group I) in all settings studied. (Ablation depth: 76.90 to 97.18µm; Coagulation depth: 186.01 to 219.84 µm). In Group II, macroscopic evaluation showed that all settings cause significant immediate skin contraction. The highest setting cause significant more intense tightening effect initially, contracting skin area from 258.65 to 179.09 mm2. The same pattern was observed in Group III. At 30 and 60 days, the lowest setting significantly sustained contraction. Lower fractional CO2 laser energies associated to pulse stacking could cause consistent and long lasting tissue contraction in rats.
Adaptation of zirconia crowns created by conventional versus optical impression: in vitro study
Bahrami, Babak; Fossoyeux, InÈs; Atash, Ramin
2017-01-01
PURPOSE The aim of this study was to compare the precision of optical impression (Trios, 3Shape) versus that of conventional impression (Imprint IV, 3M-ESPE) with three different margins (shoulder, chamfer, and knife-edge) on Frasaco teeth. MATERIALS AND METHODS The sample comprised of 60 zirconia half-crowns, divided into six groups according to the type of impression and margin. Scanning electron microscopy enabled us to analyze the gap between the zirconia crowns and the Frasaco teeth, using ImageJ software, based on eight reproducible and standardized measuring points. RESULTS No statistically significant difference was found between conventional impressions and optical impressions, except for two of the eight points. A statistically significant difference was observed between the three margin types; the chamfer and knife-edge finishing lines appeared to offer better adaptation results than the shoulder margin. CONCLUSION Zirconia crowns created from optical impression and those created from conventional impression present similar adaptation. While offering identical results, the former have many advantages. In view of our findings, we believe the chamfer margin should be favored. PMID:28680553
NASA Astrophysics Data System (ADS)
Ho, Wen-Jeng; Feng, Sheng-Kai; Liu, Jheng-Jie; Yang, Yun-Chie; Ho, Chun-Hung
2018-05-01
This paper reports on efforts to improve the photovoltaic performance of crystalline silicon solar cells by combining the plasmonic scattering of silver nanoparticles (Ag NPs) with the luminescent downshifting (LDS) effects of Eu-doped phosphors. The surface morphology was examined using a scanning electron microscope in conjunction with ImageJ software. Raman scattering and absorbance measurements were used to examine the surface plasmon resonance of Ag NPs of various dimensions in various dielectric environments. The fluorescence emission of the Eu-doped phosphors was characterized via photoluminescence measurements at room temperature. We examined the combination of plasmonic and LDS effects by measuring the optical reflectance and external quantum efficiency. Improvements in the photovoltaic performance of the solar cells were determined by photovoltaic current density-voltage under AM 1.5G illumination. A combination of plasmonic and LDS effects led to an impressive 26.17% improvement in efficiency, whereas plasmonic effects resulted in a 22.63% improvement compared to the cell with a SiO2 ARC of 17.33%.
Root Growth Patterns and Morphometric Change Based on the Growth Media
NASA Astrophysics Data System (ADS)
Schultz, Eric R.; Paul, Anna-Lisa; Ferl, Robert J.
2016-12-01
Arabidopsis thaliana roots skew with minimal waving in the microgravity environment of the International Space Station. Root skewing and root waving have been studied on the ground as well as in spaceflight, but often using different media types. In this study, Arabidopsis seedlings were grown on nutrient media plates that were comprised of various gelling agents with varied hardness in order to better assess these media for spaceflight research experiments. ImageJ was used to quantify the root morphology of 8-dayold seedlings, while R was used to perform statistical analyses. Root growth was drastically different between Difco agar, agarose, and Phytagel. Additionally, root waving masked skewing in certain media. Regression analysis revealed overall patterns when organized by hardness but also revealed that differences in media type had more of an impact on root growth than hardness itself. Different arrangements of media around the root tip revealed that roots grown on the media surface were longer and had fewer waves per millimeter than roots grown embedded in media. The implications for spaceflight research are discussed.
Yang, Longqiang; Tanabe, Koji; Miura, Tadashi; Yoshinari, Masao; Takemoto, Shinji; Shintani, Seikou; Kasahara, Masataka
2017-07-26
This study aimed to investigate influences of lyophilization factors and gelatin concentration on pore structures of ACG sponge. ACG sponges of different freezing temperatures (-30, -80 and -196 o C), freezing times (1, 2 and 24 h), gelatin concentrations (0.6%AC+0.15%G, 0.6%AC+0.6%G and 0.6%AC+2.4%G), and with 500 μM fluvastatin were fabricated. Pore structures including porosity and pore size were analyzed by scanning electron microscopy and ImageJ. The cytotoxic effects of ACG sponges were evaluated in vitro. Freezing temperature did not affect porosity while high freezing temperature (-30 o C) increased pore size. The high gelatin concentration group (0.6%AC+2.4%G) had decreased porosity and pore size. Freezing time and 500 μM fluvastatin did not affect pore structures. The cytotoxicity and cell proliferation assays revealed that ACG sponges had no cytotoxic effects on human mesenchymal stromal cell growth and proliferation. These results indicate that ACG sponge may be a good biomaterial scaffold for bone regeneration.
Spatial colonization of microbial cells on the rhizoplane.
NASA Astrophysics Data System (ADS)
Raynaud, Xavier; Eickhorst, Thilo; Nunan, Naoise; Kaiser, Christina; Woebken, Dagmar; Schmidt, Hannes
2017-04-01
The rhizoplane is the region where the root surface is in contact with soil and corresponds to the inner limit of the rhizosphere. At the rhizoplane level, plants exchange elements with the surrounding soil and the rhizoplane can therefore be considered as the region that drives nutrient movement and transformation in the rhizosphere. The rhizoplane differs in many respects from the bulk soil due to the far larger supply of substrates derived from the roots, with far greater microbial cell densities and reduced levels of diversity (Philippot et al., 2013). This is likely to result in completely different interaction profiles among microorganisms which may affect rhizosphere biogeochemistry. While the diversity of microorganisms associated with the rhizosphere and on the rhizoplane is getting increasing attention, knowledge on the spatial organisation of this diversity is still scarce. We therefore aimed at investigating the spatial arrangement of microbial rhizoplane colonization to increase our understanding of potential interaction dynamics within soil-microbe-plant interfaces. To study the spatial distribution of microbial cells on roots we cultivated rice plants in water-logged paddy soil. Root samples were taken three months after germination. After removing adhering rhizosphere soil the root samples were chemically fixed and prepared for CARD-FISH (Schmidt & Eickhorst, 2014). For hybridization, the oligonucleotide probes EUB I-III (Daims et al., 1999) were applied to cover the majority of bacteria colonizing the rhizoplane. Root segments were then subjected to confocal laser scanning microscopy where triplicate image stacks of 10 µm thickness (0.5 µm layer distance) were acquired per region of interest (ROI). ROIs were defined as distances from the root tip (0, 5, 10, 15 mm) and corresponded to the root tip, elongation zone, and zone of maturation. Image stacks were processed using ImageJ software to extract microbial cells spatial coordinates, as well as other features of the root (e.g. root cell walls). For all the images analysed, we found that microbial cell distributions were not distributed randomly and strongly associated to root cell walls. The spatial organization of root cell walls could be used to simulate microbial cell distribution that have similar spatial properties compared to the microscopic data. Root cell walls thus appear as a strong determinant for microbial cell colonization of the rhizoplane.
A software solution for recording circadian oscillator features in time-lapse live cell microscopy.
Sage, Daniel; Unser, Michael; Salmon, Patrick; Dibner, Charna
2010-07-06
Fluorescent and bioluminescent time-lapse microscopy approaches have been successfully used to investigate molecular mechanisms underlying the mammalian circadian oscillator at the single cell level. However, most of the available software and common methods based on intensity-threshold segmentation and frame-to-frame tracking are not applicable in these experiments. This is due to cell movement and dramatic changes in the fluorescent/bioluminescent reporter protein during the circadian cycle, with the lowest expression level very close to the background intensity. At present, the standard approach to analyze data sets obtained from time lapse microscopy is either manual tracking or application of generic image-processing software/dedicated tracking software. To our knowledge, these existing software solutions for manual and automatic tracking have strong limitations in tracking individual cells if their plane shifts. In an attempt to improve existing methodology of time-lapse tracking of a large number of moving cells, we have developed a semi-automatic software package. It extracts the trajectory of the cells by tracking theirs displacements, makes the delineation of cell nucleus or whole cell, and finally yields measurements of various features, like reporter protein expression level or cell displacement. As an example, we present here single cell circadian pattern and motility analysis of NIH3T3 mouse fibroblasts expressing a fluorescent circadian reporter protein. Using Circadian Gene Express plugin, we performed fast and nonbiased analysis of large fluorescent time lapse microscopy datasets. Our software solution, Circadian Gene Express (CGE), is easy to use and allows precise and semi-automatic tracking of moving cells over longer period of time. In spite of significant circadian variations in protein expression with extremely low expression levels at the valley phase, CGE allows accurate and efficient recording of large number of cell parameters, including level of reporter protein expression, velocity, direction of movement, and others. CGE proves to be useful for the analysis of widefield fluorescent microscopy datasets, as well as for bioluminescence imaging. Moreover, it might be easily adaptable for confocal image analysis by manually choosing one of the focal planes of each z-stack of the various time points of a time series. CGE is a Java plugin for ImageJ; it is freely available at: http://bigwww.epfl.ch/sage/soft/circadian/.
Schulze, Katja; Lang, Imke; Enke, Heike; Grohme, Diana; Frohme, Marcus
2015-04-17
Ethanol production via genetically engineered cyanobacteria is a promising solution for the production of biofuels. Through the introduction of a pyruvate decarboxylase and alcohol dehydrogenase direct ethanol production becomes possible within the cells. However, during cultivation genetic instability can lead to mutations and thus loss of ethanol production. Cells then revert back to the wild type phenotype. A method for a rapid and simple detection of these non-producing revertant cells in an ethanol producing cell population is an important quality control measure in order to predict genetic stability and the longevity of a producing culture. Several comparable cultivation experiments revealed a difference in the pigmentation for non-producing and producing cells: the accessory pigment phycocyanin (PC) is reduced in case of the ethanol producer, resulting in a yellowish appearance of the culture. Microarray and western blot studies of Synechocystis sp. PCC6803 and Synechococcus sp. PCC7002 confirmed this PC reduction on the level of RNA and protein. Based on these findings we developed a method for fluorescence microscopy in order to distinguish producing and non-producing cells with respect to their pigmentation phenotype. By applying a specific filter set the emitted fluorescence of a producer cell with a reduced PC content appeared orange. The emitted fluorescence of a non-producing cell with a wt pigmentation phenotype was detected in red, and dead cells in green. In an automated process multiple images of each sample were taken and analyzed with a plugin for the image analysis software ImageJ to identify dead (green), non-producing (red) and producing (orange) cells. The results of the presented validation experiments revealed a good identification with 98 % red cells in the wt sample and 90 % orange cells in the producer sample. The detected wt pigmentation phenotype (red cells) in the producer sample were either not fully induced yet (in 48 h induced cultures) or already reverted to a non-producing cells (in long-term photobioreactor cultivations), emphasizing the sensitivity and resolution of the method. The fluorescence microscopy method displays a useful technique for a rapid detection of non-producing single cells in an ethanol producing cell population.
Dong, Wei-Feng; Canil, Sarah; Lai, Raymond; Morel, Didier; Swanson, Paul E.; Izevbaye, Iyare
2018-01-01
A new automated MYC IHC classifier based on bivariate logistic regression is presented. The predictor relies on image analysis developed with the open-source ImageJ platform. From a histologic section immunostained for MYC protein, 2 dimensionless quantitative variables are extracted: (a) relative distance between nuclei positive for MYC IHC based on euclidean minimum spanning tree graph and (b) coefficient of variation of the MYC IHC stain intensity among MYC IHC-positive nuclei. Distance between positive nuclei is suggested to inversely correlate MYC gene rearrangement status, whereas coefficient of variation is suggested to inversely correlate physiological regulation of MYC protein expression. The bivariate classifier was compared with 2 other MYC IHC classifiers (based on percentage of MYC IHC positive nuclei), all tested on 113 lymphomas including mostly diffuse large B-cell lymphomas with known MYC fluorescent in situ hybridization (FISH) status. The bivariate classifier strongly outperformed the “percentage of MYC IHC-positive nuclei” methods to predict MYC+ FISH status with 100% sensitivity (95% confidence interval, 94-100) associated with 80% specificity. The test is rapidly performed and might at a minimum provide primary IHC screening for MYC gene rearrangement status in diffuse large B-cell lymphomas. Furthermore, as this bivariate classifier actually predicts “permanent overexpressed MYC protein status,” it might identify nontranslocation-related chromosomal anomalies missed by FISH. PMID:27093450
Cleaning efficacy of reciprocal and rotary systems in the removal of root canal filling material
Koçak, Mustafa Murat; Koçak, Sibel; Türker, Sevinç Aktemur; Sağlam, Baran Can
2016-01-01
Aim: The aim of this study was to compare the efficacy of hand file, nickel titanium rotary instrument, and two reciprocating instruments for removing gutta-percha and sealer from the root canals. Materials and Methods: Eighty-eight mandibular premolar teeth were used. The root canals were shaped and filled with gutta-percha and a resin-based sealer. The specimens were divided into four groups according to the technique by which the root filling material was removed: Group 1 — Wave One; Group 2 — Reciproc; Group 3 — ProTaper; and Group 4 — Gates-Glidden burs and stainless steel hand file. Then teeth were split longitudinally and photographed. The images were transferred to a computer. The ratio of remaining filling material to the root canal periphery was calculated with the aid of ImageJ software. Statistical analysis was performed using Kruskal–Wallis and Mann–Whitney tests. Results: A significant difference was found among all groups (P < 0.001). The WaveOne group demonstrated significantly less remaining filling material. The greatest amount of filling material was found in specimens where gutta-percha was removed with Gates-Glidden burs and stainless steel hand file. Conclusion: The reciprocating files were found to be significantly more effective in removing the filling material from the canal walls compared to the rotational file and hand file. PMID:27099429
Synthesis and Characterization of Supramolecular Colloids.
Vilanova, Neus; De Feijter, Isja; Voets, Ilja K
2016-04-22
Control over colloidal assembly is of utmost importance for the development of functional colloidal materials with tailored structural and mechanical properties for applications in photonics, drug delivery and coating technology. Here we present a new family of colloidal building blocks, coined supramolecular colloids, whose self-assembly is controlled through surface-functionalization with a benzene-1,3,5-tricarboxamide (BTA) derived supramolecular moiety. Such BTAs interact via directional, strong, yet reversible hydrogen-bonds with other identical BTAs. Herein, a protocol is presented that describes how to couple these BTAs to colloids and how to quantify the number of coupling sites, which determines the multivalency of the supramolecular colloids. Light scattering measurements show that the refractive index of the colloids is almost matched with that of the solvent, which strongly reduces the van der Waals forces between the colloids. Before photo-activation, the colloids remain well dispersed, as the BTAs are equipped with a photo-labile group that blocks the formation of hydrogen-bonds. Controlled deprotection with UV-light activates the short-range hydrogen-bonds between the BTAs, which triggers the colloidal self-assembly. The evolution from the dispersed state to the clustered state is monitored by confocal microscopy. These results are further quantified by image analysis with simple routines using ImageJ and Matlab. This merger of supramolecular chemistry and colloidal science offers a direct route towards light- and thermo-responsive colloidal assembly encoded in the surface-grafted monolayer.
Romano, Francesco; Arrigo, Alessandro; Chʼng, Soon Wai; Battaglia Parodi, Maurizio; Manitto, Maria Pia; Martina, Elisabetta; Bandello, Francesco; Stanga, Paulo E
2018-06-05
To assess foveal and parafoveal vasculature at the superficial capillary plexus, deep capillary plexus, and choriocapillaris of patients with X-linked retinoschisis by means of optical coherence tomography angiography. Six patients with X-linked retinoschisis (12 eyes) and seven healthy controls (14 eyes) were recruited and underwent complete ophthalmologic examination, including best-corrected visual acuity, dilated fundoscopy, and 3 × 3-mm optical coherence tomography angiography macular scans (DRI OCT Triton; Topcon Corp). After segmentation and quality review, optical coherence tomography angiography slabs were imported into ImageJ 1.50 (NIH; Bethesda) and digitally binarized. Quantification of vessel density was performed after foveal avascular zone area measurement and exclusion. Patients were additionally divided into "responders" and "nonresponders" to dorzolamide therapy. Foveal avascular zone area resulted markedly enlarged at the deep capillary plexus (P < 0.001), particularly in nonresponders. Moreover, patients disclosed a significant deep capillary plexus rarefaction, when compared with controls (P: 0.04); however, a subanalysis revealed that this damage was limited to the fovea (P: 0.006). Finally, the enlargement of foveal avascular zone area positively correlated with a decline in best-corrected visual acuity (P: 0.01). Prominent foveal vascular impairment is detectable in the deep capillary plexus of patients with X-linked retinoschisis. Our results correlate with functional outcomes, suggesting a possible vascular role in X-linked retinoschisis clinical manifestations.
Quantitative analyses of variability in normal vaginal shape and dimension on MR images
Luo, Jiajia; Betschart, Cornelia; Ashton-Miller, James A.; DeLancey, John O. L.
2016-01-01
Introduction and hypothesis We present a technique for quantifying inter-individual variability in normal vaginal shape, axis, and dimension, and report findings in healthy women. Methods Eighty women (age: 28~70 years) with normal pelvic organ support underwent supine, multi-planar proton-density MRI. Vaginal width was assessed at five evenly-spaced locations, and vaginal axis, length, and surface area were quantified via ImageJ and MATLAB. Results The mid-sagittal plane angles, relative to the horizontal, of three vaginal axes were 90± 11, 72± 21, and 41± 22° (caudal to cranial, p < 0.001). The mean (± SD) vaginal widths were 17± 5, 24± 4, 30± 7, 41± 9, and 45± 12 mm at the five locations (caudal to cranial, p < 0.001). Mid-sagittal lengths for anterior and posterior vaginal walls were 63± 9 and 98 ± 18 mm respectively. The vaginal surface area was 72 ± 21 cm2 (range: 34 ~ 164 cm2). The coefficient of determination between any demographic variable and any vaginal dimension did not exceed 0.16. Conclusions Large variations in normal vaginal shape, axis, and dimensions were not explained by body size or other demographic variables. This variation has implications for reconstructive surgery, intravaginal and surgical product design, and vaginal drug delivery. PMID:26811115
Schmitter, Daniel; Wachowicz, Paulina; Sage, Daniel; Chasapi, Anastasia; Xenarios, Ioannis; Simanis; Unser, Michael
2013-01-01
The yeast Schizosaccharomyces pombe is frequently used as a model for studying the cell cycle. The cells are rod-shaped and divide by medial fission. The process of cell division, or cytokinesis, is controlled by a network of signaling proteins called the Septation Initiation Network (SIN); SIN proteins associate with the SPBs during nuclear division (mitosis). Some SIN proteins associate with both SPBs early in mitosis, and then display strongly asymmetric signal intensity at the SPBs in late mitosis, just before cytokinesis. This asymmetry is thought to be important for correct regulation of SIN signaling, and coordination of cytokinesis and mitosis. In order to study the dynamics of organelles or large protein complexes such as the spindle pole body (SPB), which have been labeled with a fluorescent protein tag in living cells, a number of the image analysis problems must be solved; the cell outline must be detected automatically, and the position and signal intensity associated with the structures of interest within the cell must be determined. We present a new 2D and 3D image analysis system that permits versatile and robust analysis of motile, fluorescently labeled structures in rod-shaped cells. We have designed an image analysis system that we have implemented as a user-friendly software package allowing the fast and robust image-analysis of large numbers of rod-shaped cells. We have developed new robust algorithms, which we combined with existing methodologies to facilitate fast and accurate analysis. Our software permits the detection and segmentation of rod-shaped cells in either static or dynamic (i.e. time lapse) multi-channel images. It enables tracking of two structures (for example SPBs) in two different image channels. For 2D or 3D static images, the locations of the structures are identified, and then intensity values are extracted together with several quantitative parameters, such as length, width, cell orientation, background fluorescence and the distance between the structures of interest. Furthermore, two kinds of kymographs of the tracked structures can be established, one representing the migration with respect to their relative position, the other representing their individual trajectories inside the cell. This software package, called "RodCellJ", allowed us to analyze a large number of S. pombe cells to understand the rules that govern SIN protein asymmetry. (Continued on next page) (Continued from previous page). "RodCellJ" is freely available to the community as a package of several ImageJ plugins to simultaneously analyze the behavior of a large number of rod-shaped cells in an extensive manner. The integration of different image-processing techniques in a single package, as well as the development of novel algorithms does not only allow to speed up the analysis with respect to the usage of existing tools, but also accounts for higher accuracy. Its utility was demonstrated on both 2D and 3D static and dynamic images to study the septation initiation network of the yeast Schizosaccharomyces pombe. More generally, it can be used in any kind of biological context where fluorescent-protein labeled structures need to be analyzed in rod-shaped cells. RodCellJ is freely available under http://bigwww.epfl.ch/algorithms.html.
Align and random electrospun mat of PEDOT:PSS and PEDOT:PSS/RGO
NASA Astrophysics Data System (ADS)
Sarabi, Ghazale Asghari; Latifi, Masoud; Bagherzadeh, Roohollah
2018-01-01
In this research work we fabricated two ultrafine conductive nanofibrous layers to investigate the materilas composition and their properties for the preparation of supercapacitor materials application. In first layer, a polymer and a conductive polymer were used and second layer was a composition of polymer, conductive polymer and carbon-base material. In both cases align and randomized mat of conductive nanofibers were fabricated using electrospinning set up. Conductive poly (3,4-ethylenedioxythiophene)/ polystyrene sulfonate (PEDOT:PSS) nanofibers were electrospun by dissolving fiber-forming polymer and polyvinyl alcohol (PVA) in an aqueous dispersion of PEDOT:PSS. The effect of addition of reduced graphene oxide (RGO) was considered for nanocomposite layer. The ultrafine conductive polymer fibers and conductive nanocomposite fibrous materials were also fabricated using an electrospinning process. A fixed collector and a rotating drum were used for random and align nanofibers production, respectively. The resulted fibers were characterized and analyzed by SEM, FTIR and two-point probe conductivity test. The average diameter of nanofibers measured by ImageJ software indicated that the average fiber diameter for first layer was 100 nm and for nanocomposite layer was about 85 nm. The presence of PEDOT:PSS and RGO in the nanofibers was confirmed by FT-IR spectroscopy. The conductivity of align and random layers was characterized. The conductivity of PEDOT:PSS nanofibers showed higher enhancement by addition of RGO in aqueous dispersion. The obtained results showed that alignment of fibrous materials can be considered as an engineering tool for tuning the conductivity of fibrous materials for many different applications such as supercapacitors, conductive and transparent materials.
A simple optical tweezers for trapping polystyrene particles
NASA Astrophysics Data System (ADS)
Shiddiq, Minarni; Nasir, Zulfa; Yogasari, Dwiyana
2013-09-01
Optical tweezers is an optical trap. For decades, it has become an optical tool that can trap and manipulate any particle from the very small size like DNA to the big one like bacteria. The trapping force comes from the radiation pressure of laser light which is focused to a group of particles. Optical tweezers has been used in many research areas such as atomic physics, medical physics, biophysics, and chemistry. Here, a simple optical tweezers has been constructed using a modified Leybold laboratory optical microscope. The ocular lens of the microscope has been removed for laser light and digital camera accesses. A laser light from a Coherent diode laser with wavelength λ = 830 nm and power 50 mW is sent through an immersion oil objective lens with magnification 100 × and NA 1.25 to a cell made from microscope slides containing polystyrene particles. Polystyrene particles with size 3 μm and 10 μm are used. A CMOS Thorlabs camera type DCC1545M with USB Interface and Thorlabs camera lens 35 mm are connected to a desktop and used to monitor the trapping and measure the stiffness of the trap. The camera is accompanied by camera software which makes able for the user to capture and save images. The images are analyzed using ImageJ and Scion macro. The polystyrene particles have been trapped successfully. The stiffness of the trap depends on the size of the particles and the power of the laser. The stiffness increases linearly with power and decreases as the particle size larger.
Accuracy of Gypsum Casts after Different Impression Techniques and Double Pouring
Silva, Stephania Caroline Rodolfo; Messias, Aion Mangino; Abi-Rached, Filipe de Oliveira; de Souza, Raphael Freitas; Reis, José Maurício dos Santos Nunes
2016-01-01
This study evaluated the accuracy of gypsum casts after different impression techniques and double pouring. Ten patients were selected and for each one it was obtained 5 partial putty/wash impressions with vinyl polysiloxane (VPS) material from teeth #13 to #16 with partial metal stock trays. The following techniques were performed: (1) one-step; two-step relief with: (2) PVC film; (3) slow-speed tungsten carbide bur and scalpel blade, (4) small movements of the tray and (5) without relief—negative control. The impressions were disinfected with 0.5% sodium hypochlorite for 10 minutes and stored during 110 and 230 minutes for the first and second pouring, respectively, with type IV gypsum. Three intra-oral lateral photographs of each patient were taken using a tripod and a customized radiographic positioner. The images were imported into ImageJ software and the total area of the buccal surface from teeth #13 to #16 was measured. A 4.0% coefficient of variance was criterion for using these measurements as Baseline values. The casts were photographed and analyzed using the same standardization for the clinical images. The area (mm2) obtained from the difference between the measurements of each gypsum cast and the Baseline value of the respective patient were calculated and analyzed by repeated-measures two way-ANOVA and Mauchly’s Sphericity test (α = 0.05). No significant effect was observed for Impression technique (P = 0.23), Second pouring (P = 0.99) and their interaction (P = 0.25). The impression techniques and double pouring did not influence the accuracy of the gypsum casts. PMID:27736967
Accuracy of Gypsum Casts after Different Impression Techniques and Double Pouring.
Silva, Stephania Caroline Rodolfo; Messias, Aion Mangino; Abi-Rached, Filipe de Oliveira; de Souza, Raphael Freitas; Reis, José Maurício Dos Santos Nunes
2016-01-01
This study evaluated the accuracy of gypsum casts after different impression techniques and double pouring. Ten patients were selected and for each one it was obtained 5 partial putty/wash impressions with vinyl polysiloxane (VPS) material from teeth #13 to #16 with partial metal stock trays. The following techniques were performed: (1) one-step; two-step relief with: (2) PVC film; (3) slow-speed tungsten carbide bur and scalpel blade, (4) small movements of the tray and (5) without relief-negative control. The impressions were disinfected with 0.5% sodium hypochlorite for 10 minutes and stored during 110 and 230 minutes for the first and second pouring, respectively, with type IV gypsum. Three intra-oral lateral photographs of each patient were taken using a tripod and a customized radiographic positioner. The images were imported into ImageJ software and the total area of the buccal surface from teeth #13 to #16 was measured. A 4.0% coefficient of variance was criterion for using these measurements as Baseline values. The casts were photographed and analyzed using the same standardization for the clinical images. The area (mm2) obtained from the difference between the measurements of each gypsum cast and the Baseline value of the respective patient were calculated and analyzed by repeated-measures two way-ANOVA and Mauchly's Sphericity test (α = 0.05). No significant effect was observed for Impression technique (P = 0.23), Second pouring (P = 0.99) and their interaction (P = 0.25). The impression techniques and double pouring did not influence the accuracy of the gypsum casts.
NASA Astrophysics Data System (ADS)
Ghanbarzadeh, S.; Hesse, M. A.; Prodanovic, M.; Gardner, J. E.
2013-12-01
Salt deposits in sedimentary basins have long been considered to be a seal against fluid penetration. However, experimental, theoretical and field evidence suggests brine (and oil) can wet salt crystal surfaces at higher pressures and temperatures, which can form a percolating network. This network may act as flow conduits even at low porosities. The aim of this work is to investigate the effects of dihedral angle and porosity on the formation of percolating paths in different salt network lattices. However, previous studies considered only simple homogeneous and isotropic geometries. This work extends the analysis to realistic salt textures by presenting a novel numerical method to describe the texturally equilibrated pore shapes in polycrystalline rock salt and brine systems. First, a theoretical interfacial topology was formulated to minimize the interfacial surface between brine and salt. Then, the resulting nonlinear system of ordinary differential equations was solved using the Newton-Raphson method. Results show that the formation of connected fluid channels is more probable in lower dihedral angles and at higher porosities. The connectivity of the pore network is hysteretic, because the connection and disconnection at the pore throats for processes with increasing or decreasing porosities occur at different porosities. In porous media with anisotropic solids, pores initially connect in the direction of the shorter crystal axis and only at much higher porosities in the other directions. Consequently, even an infinitesimal elongation of the crystal shape can give rise to very strong anisotropy in permeability of the pore network. Also, fluid flow was simulated in the resulting pore network to calculate permeability, capillary entry pressure and velocity field. This work enabled us to investigate the opening of pore space and sealing capacity of rock salts. The obtained pore geometries determine a wide range of petrophysical properties such as permeability and capillary entry pressure. This expanded knowledge of the salt textural behavior vs. depth could also improve drilling operations in salt. Second, a series of experiments in different P-T conditions was carried out to investigate the actual shape of equilibrated channels in salt. The synthetic salt samples were scanned at the High Resolution X-ray CT Facility at the Department of Geological Science, the University of Texas at Austin with resolution in 1-6 micron range. The experimental results show both equilibrated (tubular pores) and non-equilibrated (planar features) in salt structure. Image processing was carried out by two open source software programs: ImageJ, which is a public domain Java image processing program, and 3DMA-Rock, which is a software package for quantitative analyzing of the pore space in three-dimensional X-ray computed microtomographic images of rock. We obtain medial axis and medial surface of the pore space, as well as find and characterize the corresponding pore-throat network. We also report permeability of the pore space computed using Palabos software.
Ultraviolet exposure of Gafchromic XR‐RV3 and XR‐SP2 films
Gotanda, Rumi; Gotanda, Tatsuhiro; Akagawa, Takuya; Tanki, Nobuyoshi; Kuwano, Tadao; Yabunaka, Kouichi
2015-01-01
Gafchromic film has been used for X‐ray dose measurement in diagnostic examinations. Their use has been initiated for three‐dimensional X‐ray dose measurement by using the high‐resolution characteristics of Gafchromic films in computed tomography. However, it is necessary to solve the problem of nonuniform thickness in the active layers of Gafchromic films. A double exposure technique using X‐rays is performed in therapeutic radiology; it is difficult to use in a diagnostic examination because of the heel effect. Therefore, it is suggested that ultraviolet (UV) rays be substituted for X‐rays. However, the appropriate UV wavelength is unknown. In this study, we aimed to determine which UV wavelengths are effective to expose Gafchromic XR‐RV3 and XR‐SP2. UV lamps with peak wavelengths of 245 nm, 310 nm, and 365 nm were used. The three UV wavelengths were used to irradiate Gafchromic XR‐RV3 and XR‐SP2 films for 60 min, and irradiation was repeated every 60 min for 600 min thereafter. Films were scanned after each irradiation period on a flatbed scanner. The images were split into their red‐green‐blue components, and red images were stored using ImageJ version 1.44o image analysis software. Regions of interest (ROI), 0.5 inches in diameter, were placed at the centers of the subtracted Gafchromic film images, and graphs of UV irradiation duration and mean pixel values were plotted. There were reactions to UV‐A on both Gafchromic XR‐RV3 and XR‐SP2; those to UV‐B were moderate. However, UV‐C demonstrated few reactions with Gafchromic XR‐RV3 and XR‐SP2. From these results, irradiation with UV‐A may be able to correct nonuniformity errors. Uniform UV‐A irradiation of Gafchromic films with large areas is possible, and UV rays can be used as a substitute for X‐rays in the double exposure technique. PACS number: 87.53 Bn PMID:26699326
SU-F-T-580: New Tumor Modeling Using 3D Gel Dosimeter for Brain Stereoctactic Radiotherpy (SRT)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, K; Kim, M; Kwak, J
Purpose: The purpose of this study is to develop new tumor model using 3D printing with 3D dosimeter for brain stereoctactic radiotherpy (SRT). Methods: BANG{sup 3} polymer gel was prepared and the gel-filled glass vials were irradiated with a 6 MV photon beam to acquire the calibration curve that present the change of R2 (1/T{sub 2}) value with dose. Graded doses from 0 to 12 Gy with an interval of 2 Gy were delivered. A kit for calibration of gel dosimeter and an 2 tumor model phantoms with a spherical shape were produced using a 3D printer with a polylacticmore » acid after its 3D images were created using Autodesk software. 3D printed tumor phantoms and EBT3 films were irradiated to compare with treatment plan. After irradiation, vials for calibration and tumor model phantoms were scanned at 9.4T MRI. The spin-spin relaxation times (T{sub 2}) according to the each dose were calculated to evaluate the dose response. Acquired images were analyzed using an ImageJ. Scanned MRI images of tumor models were transferred treatment planning system and these were registered to the CT images. In all treatment plans, two arc plans (CW and CCW) were designed to deliver 50 Gy for 10 fractions. For first PTV, treatment plan was accurately designed that 95% of dose to cover 100% of PTV. But 2nd PTV was not intentionally cover 100% of PTV to evaluate the intensity of delivered tumor phantom with polymer gel. We compared the 3D dose distributions obtained from measurements with the 3D printed phantom and calculated with the TPS. Results: 3D printed phantom with a polymer gel was successfully produced. The dose distributions showed qualitatively good agreement among gel, film, and RTP data. Conclusion: A hybrid phantom represents a useful to validate the 3D dose distributions for patient-specific QA.« less
A Novel Method for Characterizing Beam Hardening Artifacts in Cone-beam Computed Tomographic Images.
Fox, Aaron; Basrani, Bettina; Kishen, Anil; Lam, Ernest W N
2018-05-01
The beam hardening (BH) artifact produced by root filling materials in cone-beam computed tomographic (CBCT) images is influenced by their radiologic K absorption edge values. The purpose of this study was to describe a novel technique to characterize BH artifacts in CBCT images produced by 3 root canal filling materials and to evaluate the effects of a zirconium (Zr)-based root filling material with a lower K edge (17.99 keV) on the production of BH artifacts. The palatal root canals of 3 phantom model teeth were prepared and root filled with gutta-percha (GP), a Zr root filling material, and calcium hydroxide paste. Each phantom tooth was individually imaged using the CS 9000 CBCT unit (Carestream, Atlanta, GA). The "light" and "dark" components of the BH artifacts were quantified separately using ImageJ software (National Institutes of Health, Bethesda, MD) in 3 regions of the root. Mixed-design analysis of variance was used to evaluate differences in the artifact area for the light and dark elements of the BH artifacts. A statistically significant difference in the area of the dark portion of the BH artifact was found between all fill materials and in all regions of the phantom tooth root (P < .05). GP generated a significantly greater dark but not light artifact area compared with Zr (P < .05). Moreover, statistically significant differences between the areas of both the light and dark artifacts were observed within all regions of the tooth root, with the greatest artifact being generated in the coronal third of the root (P < .001). Root canal filling materials with lower K edge material properties reduce BH artifacts along the entire length of the root canal and reduce the contribution of the dark artifact. Copyright © 2018 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Guo, Lei; Tao, Jun; Xia, Fan; Yang, Zhi; Ma, Xiaoli; Hua, Rui
2016-09-01
Amblyopia is a visual impairment that is attributed to either abnormal binocular interactions or visual deprivation. The retina and choroids have been shown to be involved in the development of amblyopia. The purpose of this study was to investigate the retinal and choroidal microstructural abnormalities of amblyopia using digital subtraction autofluorescence and split-spectrum amplitude-decorrelation angiography (SSADA) approaches. This prospective study included 44 eyes of 22 patients with unilateral amblyopia. All patients who received indirect ophthalmoscopy, combined depth imaging spectral domain optical coherence tomography (OCT), SSADA-OCT, and macular blue light (BL-) and near-infrared (NIR-) autofluorescences underwent pupil dilation. The subfoveal choroidal thickness (SFCT) was measured. BL- and NIR-autofluorescences were determined for all patients and used to generate subtraction images with ImageJ software. The superficial, deep layers of the retina, and inner choroid layer were required for SSADA-OCT. For the normal eyes, a regularly increasing signal was observed in the central macula based on the subtraction images. In contrast, a decreased signal for the central patch or a reduced peak was detected in 16 of 22 amblyopic eyes (72.7%). The mean SFCT of the amblyopic eyes was greater than that of the fellow normal eyes (399.25 ± 4.944 µm vs. 280.58 ± 6.491 µm, respectively, P < 0.05). SSADA-OCT revealed a normal choroidal capillary network in all fellow normal eyes. However, 18 of 22 amblyopic eyes (86.4%) exhibited a blurry choroidal capillary network, and 15 of 22 amblyopic eyes (68.2%) displayed a dark atrophic patch. This is the first report of amblyopia using SSADA-OCT and digital subtraction images of autofluorescence. The mechanistic relationship of a thicker choroid and choroidal capillary atrophy with amblyopia remains to be described. The digital subtraction image confirmed the changes in the microstructure of the amblyopic retina as a supplementary approach to detect the progression of amblyopia. Lasers Surg. Med. 48:660-667, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
SU-G-IeP4-06: Feasibility of External Beam Treatment Field Verification Using Cherenkov Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Black, P; Na, Y; Wuu, C
2016-06-15
Purpose: Cherenkov light emission has been shown to correlate with ionizing radiation (IR) dose delivery in solid tissue. In order to properly correlate Cherenkov light images with real time dose delivery in a patient, we must account for geometric and intensity distortions arising from observation angle, as well as the effect of monitor units (MU) and field size on Cherenkov light emission. To test the feasibility of treatment field verification, we first focused on Cherenkov light emission efficiency based on MU and known field size (FS). Methods: Cherenkov light emission was captured using a PI-MAX4 intensified charge coupled device(ICCD) systemmore » (Princeton Instruments), positioned at a fixed angle of 40° relative to the beam central axis. A Varian TrueBeam linear accelerator (linac) was operated at 6MV and 600MU/min to deliver an Anterior-Posterior beam to a 5cm thick block phantom positioned at 100cm Source-to-Surface-Distance(SSD). FS of 10×10, 5×5, and 2×2cm{sup 2} were used. Before beam delivery projected light field images were acquired, ensuring that geometric distortions were consistent when measuring Cherenkov field discrepancies. Cherenkov image acquisition was triggered by linac target current. 500 frames were acquired for each FS. Composite images were created through summation of frames and background subtraction. MU per image was calculated based on linac pulse delay of 2.8ms. Cherenkov and projected light FS were evaluated using ImageJ software. Results: Mean Cherenkov FS discrepancies compared to light field were <0.5cm for 5.6, 2.8, and 8.6 MU for 10×10, 5×5, and 2×2cm{sup 2} FS, respectably. Discrepancies were reduced with increasing field size and MU. We predict a minimum of 100 frames is needed for reliable confirmation of delivered FS. Conclusion: Current discrepancies in Cherenkov field sizes are within a usable range to confirm treatment delivery in standard and respiratory gated clinical scenarios at MU levels appropriate to standard MLC position segments.« less
Pires, Filipa; Ferreira, Quirina; Rodrigues, Carlos A V; Morgado, Jorge; Ferreira, Frederico Castelo
2015-06-01
The use of conjugated polymers allows versatile interactions between cells and flexible processable materials, while providing a platform for electrical stimulation, which is particularly relevant when targeting differentiation of neural stem cells and further application for therapy or drug screening. Materials were tested for cytotoxicity following the ISO10993-5. PSS was cross-linked. ReNcellVM neural stem cells (NSC) were seeded in laminin coated surfaces, cultured for 4 days in the presence of EGF (20 ng/mL), FGF-2 (20 ng/mL) and B27 (20 μg/mL) and differentiated over eight additional days in the absence of those factors under 100Hz pulsed DC electrical stimulation, 1V with 10 ms pulses. NSC and neuron elongation aspect ratio as well as neurite length were assessed using ImageJ. Cells were immune-stained for Tuj1 and GFAP. F8T2, MEH-PPV, P3HT and cross-linked PSS (x PSS) were assessed as non-cytotoxic. L929 fibroblast population was 1.3 higher for x PSS than for glass control, while F8T2 presents moderate proliferation. The population of neurons (Tuj1) was 1.6 times higher with longer neurites (73 vs 108 μm) for cells cultured under electrical stimulus, with cultured NSC. Such stimulus led also to longer neurons. x PSS was, for the first time, used to elongate human NSC through the application of pulsed current, impacting on their differentiation towards neurons and contributing to longer neurites. The range of conductive conjugated polymers known as non-cytotoxic was expanded. x PSS was introduced as a stable material, easily processed from solution, to interface with biological systems, in particular NSC, without the need of in-situ polymerization. Copyright © 2015 Elsevier B.V. All rights reserved.
Remote Sensing Soil Moisture Analysis by Unmanned Aerial Vehicles Digital Imaging
NASA Astrophysics Data System (ADS)
Yeh, C. Y.; Lin, H. R.; Chen, Y. L.; Huang, S. Y.; Wen, J. C.
2017-12-01
In recent years, remote sensing analysis has been able to apply to the research of climate change, environment monitoring, geology, hydro-meteorological, and so on. However, the traditional methods for analyzing wide ranges of surface soil moisture of spatial distribution surveys may require plenty resources besides the high cost. In the past, remote sensing analysis performed soil moisture estimates through shortwave, thermal infrared ray, or infrared satellite, which requires lots of resources, labor, and money. Therefore, the digital image color was used to establish the multiple linear regression model. Finally, we can find out the relationship between surface soil color and soil moisture. In this study, we use the Unmanned Aerial Vehicle (UAV) to take an aerial photo of the fallow farmland. Simultaneously, we take the surface soil sample from 0-5 cm of the surface. The soil will be baking by 110° C and 24 hr. And the software ImageJ 1.48 is applied for the analysis of the digital images and the hue analysis into Red, Green, and Blue (R, G, B) hue values. The correlation analysis is the result from the data obtained from the image hue and the surface soil moisture at each sampling point. After image and soil moisture analysis, we use the R, G, B and soil moisture to establish the multiple regression to estimate the spatial distributions of surface soil moisture. In the result, we compare the real soil moisture and the estimated soil moisture. The coefficient of determination (R2) can achieve 0.5-0.7. The uncertainties in the field test, such as the sun illumination, the sun exposure angle, even the shadow, will affect the result; therefore, R2 can achieve 0.5-0.7 reflects good effect for the in-suit test by using the digital image to estimate the soil moisture. Based on the outcomes of the research, using digital images from UAV to estimate the surface soil moisture is acceptable. However, further investigations need to be collected more than ten days (four times a day) data to verify the relation between the image hue and the soil moisture for reliable moisture estimated model. And it is better to use the digital single lens reflex camera to prevent the deformation of the image and to have a better auto exposure. Keywords: soil, moisture, remote sensing
Seasonal Effect on Ocular Sun Exposure and Conjunctival UV Autofluorescence.
Haworth, Kristina M; Chandler, Heather L
2017-02-01
To evaluate feasibility and repeatability of measures for ocular sun exposure and conjunctival ultraviolet autofluorescence (UVAF), and to test for relationships between the outcomes. Fifty volunteers were seen for two visits 14 ± 2 days apart. Ocular sun exposure was estimated over a 2-week time period using questionnaires that quantified time outdoors and ocular protection habits. Conjunctival UVAF was imaged using a Nikon D7000 camera system equipped with appropriate flash and filter system; image analysis was done using ImageJ software. Repeatability estimates were made using Bland-Altman plots with mean differences and 95% limits of agreement calculated. Non-normally distributed data was transformed by either log10 or square root methods. Linear regression was conducted to evaluate relationships between measures. Mean (±SD) values for ocular sun exposure and conjunctival UVAF were 8.86 (±11.97) hours and 9.15 (±9.47) mm, respectively. Repeatability was found to be acceptable for both ocular sun exposure and conjunctival UVAF. Univariate linear regression showed outdoor occupation to be a predictor of higher ocular sun exposure; outdoor occupation and winter season of collection both predicted higher total UVAF. Furthermore, increased portion of day spent outdoors while working was associated with increased total conjunctival UVAF. We demonstrate feasibility and repeatability of estimating ocular sun exposure using a previously unreported method and for conjunctival UVAF in a group of subjects residing in Ohio. Seasonal temperature variation may have influenced time outdoors and ultimately calculation of ocular sun exposure. As winter season of collection and outdoor occupation both predicted higher total UVAF, our data suggests that ocular sun exposure is associated with conjunctival UVAF and, possibly, that UVAF remains for at least several months after sun exposure.
NASA Technical Reports Server (NTRS)
Chatzimavroudis, George P.; Spirka, Thomas A.; Setser, Randolph M.; Myers, Jerry G.
2004-01-01
One of NASA's objectives is to be able to perform a complete, pre-flight, evaluation of cardiovascular changes in astronauts scheduled for prolonged space missions. Computational fluid dynamics (CFD) has shown promise as a method for estimating cardiovascular function during reduced gravity conditions. For this purpose, MRI can provide geometrical information, to reconstruct vessel geometries, and measure all spatial velocity components, providing location specific boundary conditions. The objective of this study was to investigate the reliability of MRI-based model reconstruction and measured boundary conditions for CFD simulations. An aortic arch model and a carotid bifurcation model were scanned in a 1.5T Siemens MRI scanner. Axial MRI acquisitions provided images for geometry reconstruction (slice thickness 3 and 5 mm; pixel size 1x1 and 0.5x0.5 square millimeters). Velocity acquisitions provided measured inlet boundary conditions and localized three-directional steady-flow velocity data (0.7-3.0 L/min). The vessel walls were isolated using NIH provided software (ImageJ) and lofted to form the geometric surface. Constructed and idealized geometries were imported into a commercial CFD code for meshing and simulation. Contour and vector plots of the velocity showed identical features between the MRI velocity data, the MRI-based CFD data, and the idealized-geometry CFD data, with less than 10% differences in the local velocity values. CFD results on models reconstructed from different MRI resolution settings showed insignificant differences (less than 5%). This study illustrated, quantitatively, that reliable CFD simulations can be performed with MRI reconstructed models and gives evidence that a future, subject-specific, computational evaluation of the cardiovascular system alteration during space travel is feasible.
Lee, Kwan Bok; Koh, Kyung Min; Kwon, Young A; Song, Sang Wroul; Kim, Byoung Yeop; Chung, Jae Lim
2017-08-01
To evaluate changes in the tear meniscus area and tear meniscus height over time in patients with dry eye syndrome, using anterior segment spectral-domain optical coherence tomography after the instillation of 3% diquafosol ophthalmic solution. Sixty eyes from 30 patients with mild to moderate dry eye syndrome were included. Tear meniscus images acquired by anterior segment spectral-domain optical coherence tomography were analyzed using National Institutes of Health's image-analysis software (ImageJ 1.44p). Tear meniscus area and tear meniscus height were measured at baseline, 5 minutes, 10 minutes, and 30 minutes after instillation of a drop of diquafosol in one eye and normal saline in the other eye. Changes in ocular surface disease index score, tear film break-up time, corneal staining score by Oxford schema, and meibomian expressibility were also evaluated at baseline, and after 1 week and 1 month of a diquafosol daily regimen. Sixty eyes from 30 subjects (mean age, 29.3 years; 8 men and 22 women) were included. In eyes receiving diquafosol, tear volume was increased at 5 and 10 minutes compared with baseline. It was also higher than saline instilled eyes at 5, 10, and 30 minutes. Changes in tear volume with respect to baseline were not statistically different after the use of diquafosol for 1 month. Ocular surface disease index score, tear film break-up time, and Oxford cornea stain score were significantly improved after 1 week and 1 month of daily diquafosol instillation, but meibomian expressibility did not change. Topical diquafosol ophthalmic solution effectively increased tear volume for up to 30 minutes, compared to normal saline in patients with dry eye syndrome. © 2017 The Korean Ophthalmological Society
Seasonal Effect on Ocular Sun Exposure and Conjunctival UV Autofluorescence
Haworth, Kristina M.; Chandler, Heather L.
2016-01-01
Purpose To evaluate feasibility and repeatability of measures for ocular sun exposure and conjunctival ultraviolet autofluorescence (UVAF), and to test for relationships between the outcomes. Methods Fifty volunteers were seen for 2 visits 14±2 days apart. Ocular sun exposure was estimated over a two-week time period using questionnaires that quantified time outdoors and ocular protection habits. Conjunctival UVAF was imaged using a Nikon D7000 camera system equipped with appropriate flash and filter system; image analysis was done using ImageJ software. Repeatability estimates were made using Bland-Altman plots with mean differences and 95% limits of agreement calculated. Non-normally distributed data was transformed by either log10 or square root methods. Linear regression was conducted to evaluate relationships between measures. Results Mean (±SD) values for ocular sun exposure and conjunctival UVAF were 8.86 (±11.97) hours and 9.15 (±9.47) mm2, respectively. Repeatability was found to be acceptable for both ocular sun exposure and conjunctival UVAF. Univariate linear regression showed outdoor occupation to be a predictor of higher ocular sun exposure; outdoor occupation and winter season of collection both predicted higher total UVAF. Furthermore, increased portion of day spent outdoors while working was associated with increased total conjunctival UVAF. Conclusions We demonstrate feasibility and repeatability of estimating ocular sun exposure using a previously unreported method and for conjunctival UVAF in a group of subjects residing in Ohio. Seasonal temperature variation may have influenced time outdoors and ultimately calculation of ocular sun exposure. As winter season of collection and outdoor occupation both predicted higher total UVAF, our data suggests that ocular sun exposure is associated with conjunctival UVAF and possibly, that UVAF remains for at least several months following sun exposure. PMID:27820717
Bernard, Aurélien; He, Zhiguo; Gauthier, Anne Sophie; Trone, Marie Caroline; Baubeau, Emmanuel; Forest, Fabien; Dumollard, Jean Marc; Peocʼh, Michel; Thuret, Gilles; Gain, Philippe
2015-02-01
Stromal surface quality of endothelial lamellae cut for endothelial keratoplasty with a femtosecond laser (FSL) with epithelial applanation remains disappointing. Applanation of the endothelial side of the cornea, mounted inverted on an artificial chamber, has therefore been proposed to improve cut quality. We compared lamellar quality after FSL cutting using epithelial versus endothelial applanation. Lamellae were cut with an FSL from organ-cultured corneas. After randomization, 7 were cut with epithelial applanation and 7 with endothelial applanation. Lamellae of 50-, 75-, and 100-μm thickness were targeted. Thickness was measured by optical coherence tomography before and immediately after cutting. Viable endothelial cell density was quantified immediately after cutting using triple labeling with Hoechst/ethidium/calcein-AM coupled with image analysis with ImageJ. The stromal surface was evaluated by 9 masked observers using semiquantitative scoring of scanning electronic microscopy images. Histology of 2 samples was also analyzed before lamellar detachment. Precision (difference in target/actual thickness) and thickness regularity [coefficient of variation (CV) of 10 measurements] were significantly better with endothelial applanation (precision: 18 μm; range, 10-30; CV: 11%; range, 8-12) than with epithelial applanation (precision: 84 μm; range, 54-107; P = 0.002; CV: 24%; range, 13-47; P = 0.001). Endothelial applanation provided thinner lamellae. However, viable endothelial cell density was significantly lower after endothelial applanation (1183 cells/mm2; range, 787-1725 versus 1688 cells/mm2; range, 1288-2025; P = 0.018). FSL cutting of endothelial lamellae using endothelial applanation provides thinner more regular grafts with more predictable thickness than with conventional epithelial applanation but strongly reduces the pool of viable endothelial cells.
Schmitz, Christoph; Eastwood, Brian S.; Tappan, Susan J.; Glaser, Jack R.; Peterson, Daniel A.; Hof, Patrick R.
2014-01-01
Stereologic cell counting has had a major impact on the field of neuroscience. A major bottleneck in stereologic cell counting is that the user must manually decide whether or not each cell is counted according to three-dimensional (3D) stereologic counting rules by visual inspection within hundreds of microscopic fields-of-view per investigated brain or brain region. Reliance on visual inspection forces stereologic cell counting to be very labor-intensive and time-consuming, and is the main reason why biased, non-stereologic two-dimensional (2D) “cell counting” approaches have remained in widespread use. We present an evaluation of the performance of modern automated cell detection and segmentation algorithms as a potential alternative to the manual approach in stereologic cell counting. The image data used in this study were 3D microscopic images of thick brain tissue sections prepared with a variety of commonly used nuclear and cytoplasmic stains. The evaluation compared the numbers and locations of cells identified unambiguously and counted exhaustively by an expert observer with those found by three automated 3D cell detection algorithms: nuclei segmentation from the FARSIGHT toolkit, nuclei segmentation by 3D multiple level set methods, and the 3D object counter plug-in for ImageJ. Of these methods, FARSIGHT performed best, with true-positive detection rates between 38 and 99% and false-positive rates from 3.6 to 82%. The results demonstrate that the current automated methods suffer from lower detection rates and higher false-positive rates than are acceptable for obtaining valid estimates of cell numbers. Thus, at present, stereologic cell counting with manual decision for object inclusion according to unbiased stereologic counting rules remains the only adequate method for unbiased cell quantification in histologic tissue sections. PMID:24847213
Ishii, Naoko; Kawano, Yayoi; Sakai, Hideki; Hayashi, Seitaku; Akizuki, Norikazu; Komoda, Masayo; Hanawa, Takehisa
2017-08-01
Anticancer drug-induced stomatitis develops in 30% to 40% of cancer cases that undergo chemotherapy. However, medications for this condition are not commercially available in Japan. Upon obtaining approval of the ethics committee, a mouthwash containing rebamipide as the active ingredient (rebamipide mouthwash) was administered to one inpatient and four outpatients, who had developed stomatitis caused by cancer chemotherapy. Starting from 14 d after the administration of the rebamipide mouthwash, the patients scored a stomatitis survey on oral state, pain level, and diet and recorded the number of times they gargled, as well as any stomatitis observations, in a stomatitis diary. The total scores for the points for each of the three types of survey sections were classified into Grades 0 to 4 and evaluated as a stomatitis evaluation score (SES). The SES became "0" in three out of the five patients within 14 d of treatment. No change in SES was found in one patient. In the remaining patients, SES became "0" once but increased again later. Using image analysis software (ImageJ), the area at which the stomatitis was observed was measured. When comparing SES and change in the area in patients who agreed to participate, gradual reductions in the extent of stomatitis was observed even during the period when SES did not change. Having patients fill in an observation chart was effective for grasping changes in symptoms in outpatients.
Shawky, Eman; Selim, Dina A
2017-09-01
The evaluation of extraction protocols for untargeted and targeted metabolomics was implemented for root and aerial organs of Astragalus spinosus in this work. The efficiency and complementarity of commonly used extraction solvents, namely petroleum ether, methylene chloride, ethyl acetate and n-butanol were considered for method evaluation using chemometric techniques in conjunction with new, simple, and fast high performance thin layer chromatography (HPTLC) method for fingerprint analysis by extracting information from a digitalized HPTLC plate using ImageJ software. A targeted approach was furtherly implemented by developing and validating an HPTLC method allowing the quantification of three saponin glycosides. The results of untargeted and targeted principle component analysis (PCA) and hierarchical cluster analysis (HCA) revealed that the apparent saponins profile seems to depend on a combined effect of matrix composition and the properties of the selected solvent for extraction, where both the biological matrix of the investigated plant organs, as well as the extraction solvent can influence the precision of metabolite abundances. Although, the aerial part is frequently discarded as waste, it is shown hereby that it has similar chemical profile compared to the medicinal part, roots, yet a different extraction solvents pattern is recognized between the two organs which can be attributed to the differences in the composition, permeability or accessibility of the sample matrix/organ tissues, rather than the chemical structures of the detected metabolites. Copyright © 2017 Elsevier B.V. All rights reserved.
Radiation-induced impairment in lung lymphatic vasculature.
Cui, Ye; Wilder, Julie; Rietz, Cecilia; Gigliotti, Andrew; Tang, Xiaomeng; Shi, Yuanyuan; Guilmette, Raymond; Wang, Hao; George, Gautam; Nilo de Magaldi, Eduarda; Chu, Sarah G; Doyle-Eisele, Melanie; McDonald, Jacob D; Rosas, Ivan O; El-Chemaly, Souheil
2014-12-01
The lymphatic vasculature has been shown to play important roles in lung injury and repair, particularly in lung fibrosis. The effects of ionizing radiation on lung lymphatic vasculature have not been previously reported. C57Bl/6 mice were immobilized in a lead shield exposing only the thoracic cavity, and were irradiated with a single dose of 14 Gy. Animals were sacrificed and lungs collected at different time points (1, 4, 8, and 16 weeks) following radiation. To identify lymphatic vessels in lung tissue sections, we used antibodies that are specific for lymphatic vessel endothelial receptor 1 (LYVE-1), a marker of lymphatic endothelial cells (LEC). To evaluate LEC cell death and oxidative damage, lung tissue sections were stained for LYVE-1 and with TUNEL staining, or 8-oxo-dG respectively. Images were imported into ImageJ v1.36b and analyzed. Compared to a non-irradiated control group, we observed a durable and progressive decrease in the density, perimeter, and area of lymphatic vessels over the study period. The decline in the density of lymphatic vessels was observed in both subpleural and interstitial lymphatics. Histopathologically discernible pulmonary fibrosis was not apparent until 16 weeks after irradiation. Furthermore, there was significantly increased LEC apoptosis and oxidative damage at one week post-irradiation that persisted at 16 weeks. There is impairment of lymphatic vasculature after a single dose of ionizing radiation that precedes architectural distortion and fibrosis, suggesting important roles for the lymphatic circulation in the pathogenesis of the radiation-induced lung injury.
Kuswandi, Bambang; Irmawati, Titi; Hidayat, Moch Amrun; Jayus; Ahmad, Musa
2014-01-27
A simple visual ethanol biosensor based on alcohol oxidase (AOX) immobilised onto polyaniline (PANI) film for halal verification of fermented beverage samples is described. This biosensor responds to ethanol via a colour change from green to blue, due to the enzymatic reaction of ethanol that produces acetaldehyde and hydrogen peroxide, when the latter oxidizes the PANI film. The procedure to obtain this biosensor consists of the immobilization of AOX onto PANI film by adsorption. For the immobilisation, an AOX solution is deposited on the PANI film and left at room temperature until dried (30 min). The biosensor was constructed as a dip stick for visual and simple use. The colour changes of the films have been scanned and analysed using image analysis software (i.e., ImageJ) to study the characteristics of the biosensor's response toward ethanol. The biosensor has a linear response in an ethanol concentration range of 0.01%-0.8%, with a correlation coefficient (r) of 0.996. The limit detection of the biosensor was 0.001%, with reproducibility (RSD) of 1.6% and a life time up to seven weeks when stored at 4 °C. The biosensor provides accurate results for ethanol determination in fermented drinks and was in good agreement with the standard method (gas chromatography) results. Thus, the biosensor could be used as a simple visual method for ethanol determination in fermented beverage samples that can be useful for Muslim community for halal verification.
Subramaniam, Ranjeeta; Mani, Mohan Prasath; Jaganathan, Saravana Kumar
2018-04-26
In this study, a small vascular graft based on polyurethane (PU) blended with chitosan (Ch) nanoparticles was fabricated using electrospinning technique. Initially, the chitosan nanoparticles were synthesized using ionic gelation method. UV-Vis spectrophotometer confirmed the presence of synthesized Ch nanoparticles by exhibiting absorption peak at 288 nm and the Fourier-transform infrared spectroscopy (FTIR) analysis confirmed the existence of the chitosan. Further, the synthesized Ch nanoparticles showed size diameter in the range of 134 ± 58 nm as measured using ImageJ. In the electrospun PU/chitosan graft, the fiber diameter and pore size diameter was found to be reduced compared to the pure PU owing to incorporation of chitosan into PU matrix. The FTIR spectrum revealed the presence of chitosan in the prepared nanocomposite membrane by the formation of the hydrogen bond and peak shift of CH and NH stretching. Moreover, the contact angle measurements revealed that the prepared graft showed decreased contact angle indicating hydrophilic nature compared to the pristine PU. The cytocompatibility studies revealed the non-toxic behavior of the fabricated graft. Hence, the prepared graft exhibiting significant physiochemical and non-toxic properties may be a plausible candidate for cardiovascular graft applications.
NASA Astrophysics Data System (ADS)
Khanal, Lokendra Raj; Williams, Thomas; Qiang, You
2018-06-01
Iron/iron-oxide (Fe–Fe3O4) core–shell nanoclusters (NCs) synthesized by a cluster deposition technique were subjected to a study of their high temperature structural and morphological behavior. Annealing effects have been investigated up to 800 °C in vacuum, oxygen and argon environments. The ~18 nm average size of the as-prepared NCs increases slowly in temperatures up to 500 °C in all three environments. The size increases abruptly in the argon environment but slowly in vacuum and oxygen when annealed at 800 °C. The x-ray diffraction (XRD) studies have shown that the iron core remains in the core–shell NCs only when they were annealed in the vacuum. A dramatic change in the surface morphology, an island like structure and/or a network like pattern, was observed at the elevated temperature. The as-prepared and annealed samples were analyzed using XRD, scanning electron microscopy and imageJ software for a close inspection of the temperature aroused properties. This work presents the temperature induced size growth mechanism, oxidation kinetics and phase transformation of the NCs accompanied by cluster aggregation, particle coalescence, and diffusion.
Chen, Feng; Zhang, Jinwen
2010-11-01
In this study, soy protein concentrate (SPC) was used as a plastic component to blend with poly(butylene adipate-co-terephthalate) (PBAT). Effects of SPC plasticization and blend composition on its deformation during mixing were studied in detail. Influence of using water as the major plasticizer and glycerol as the co-plasticizer on the deformation of the SPC phase during mixing was explored. The effect of shear stress, as affected by SPC loading level, on the phase structure of SPC in the blends was also investigated. Quantitative analysis of the aspect ratio of SPC particles was conducted by using ImageJ software, and an empirical model predicting the formation of percolated structure was applied. The experimental results and the model prediction showed a fairly good agreement. The experimental results and statistic analysis suggest that both SPC loading level and its water content prior to compounding had significant influences on development of the SPC phase structure and were correlated in determining the morphological structures of the resulting blends. Consequently, physical and mechanical properties of the blends greatly depended on the phase morphology and PBAT/SPC ratio of the blends.
Osteogenic potential of a chalcone in a critical-size defect in rat calvaria bone.
Ortolan, Xana Raquel; Fenner, Bruna Proiss; Mezadri, Telmo José; Tames, David Rivero; Corrêa, Rogério; de Campos Buzzi, Fátima
2014-07-01
This study describes the bone formation stimulated by the application of a type of chalcone to critical-size defects in rat calvarial bone. Sixty female Wistar rats were divided into 6 groups of 10 animals per group: control (no treatment), vehicle (vaseline) and the chalcone (1-phenyl-3-(4-chlorophenyl)-2-propen-1-one) suspended in vaseline at 10%. A critical-size defect of 5 mm was prepared using a trephine in the calvarial bone, after which the treatment was applied, in a single dose, according to the experimental group. The samples were evaluated macroscopically using ImageJ software, and histologically 30 and 45 days after surgery. At 30 days after surgery, there was significant bone formation (p < 0.05) in the groups treated with chalcone, compared with the other groups. Many active osteoblasts were observed adjacent to the borders of the newly formed bone tissue. 45 days after surgery in the chalcone group, the surgical defects showed complete bone closure. The results of this study suggest that chalcone has significant potential to induce the formation of new bone. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Dermatoglyphic features in patients with multiple sclerosis
Sabanciogullari, Vedat; Cevik, Seyda; Karacan, Kezban; Bolayir, Ertugrul; Cimen, Mehmet
2014-01-01
Objective: To examine dermatoglyphic features to clarify implicated genetic predisposition in the etiology of multiple sclerosis (MS). Methods: The study was conducted between January and December 2013 in the Departments of Anatomy, and Neurology, Cumhuriyet University School of Medicine, Sivas, Turkey. The dermatoglyphic data of 61 patients, and a control group consisting of 62 healthy adults obtained with a digital scanner were transferred to a computer environment. The ImageJ program was used, and atd, dat, adt angles, a-b ridge count, sample types of all fingers, and ridge counts were calculated. Results: In both hands of the patients with MS, the a-b ridge count and ridge counts in all fingers increased, and the differences in these values were statistically significant. There was also a statistically significant increase in the dat angle in both hands of the MS patients. On the contrary, there was no statistically significant difference between the groups in terms of dermal ridge samples, and the most frequent sample in both groups was the ulnar loop. Conclusions: Aberrations in the distribution of dermatoglyphic samples support the genetic predisposition in MS etiology. Multiple sclerosis susceptible individuals may be determined by analyzing dermatoglyphic samples. PMID:25274586
Takase, Noriaki; Nozaki, Miho; Kato, Aki; Ozeki, Hironori; Yoshida, Munenori; Ogura, Yuichiro
2015-11-01
To evaluate the area of the foveal avascular zone (FAZ) detected by en face OCTA (AngioVue, Avanti OCT; Optovue) in healthy and diabetic eyes. Retrospective chart review of patients who underwent fundus examination including en face OCTA. Eyes with proliferative diabetic retinopathy and history of laser photocoagulation were excluded. The FAZ area in the superficial and deep plexus layers were measured and evaluated using ImageJ software. The FAZ area in the superficial layer was 0.25 ± 0.06 mm² in healthy eyes (n = 19), whereas it was 0.37 ± 0.07 mm² in diabetic eyes without retinopathy (n = 24) and 0.38 ± 0.11 mm² in eyes with diabetic retinopathy (n = 20). Diabetic eyes showed statistically significant FAZ enlargement compared with healthy eyes, regardless of the presence of retinopathy (P < 0.01). The FAZ area in the deep plexus layer was also significantly larger in diabetic eyes than in healthy eyes (P < 0.01). Our data suggest that diabetic eyes show retinal microcirculation impairment in the macula even before retinopathy develops. En face OCTA is a useful noninvasive screening tool for detecting early microcirculatory disturbance in patients with diabetes.
Rodrigues, Daniela; Freitas, Marisa; Marisa Costa, Vera; Arturo Lopez-Quintela, Manuel; Rivas, José; Freitas, Paulo; Carvalho, Félix; Fernandes, Eduarda; Silva, Paula
2017-03-01
Understanding in vivo biodistribution of iron oxide nanoparticles (IONs), and the involvement of the phagocyte system in this process, is crucial for the assessment of their potential health risk. In the present study, the histochemical expression of iron in liver and spleen sections of CD-1 mice (aged 8 weeks) was quantified, 24 h after intravenous administration of polyacrylic acid-coated IONs (PAA-coated IONs) (8, 20, 50 mg/kg). Organ sections were stained with Perls' Prussian blue for iron detection, followed by the quantification of iron deposition with ImageJ software. Our study revealed the existence of a linear dose-dependent increase of iron deposition in macrophages of both organs. Exposed animals showed hepatic iron deposition in all zones, although most marked in periportal region. In the spleen, no iron was detected in the white splenic pulp of both control and treated animals. When compared with control mice, a positive correlation between histochemical detection of iron and PAA-coated ION doses was observed in splenic red pulp of animals. The results confirmed our assumption that liver and spleen are involved in the clearance pathways of PAA-coated IONs from the blood. Excess iron was cytotoxic at the highest dose of PAA-coated IONs tested, but no significant morphologic alterations were observed for the lower doses. Clusters of early necrotic hepatocytes were observed in the hepatic periportal region of mice injected with the higher dose (50 mg/kg) of PAA-coated IONs. Further studies are necessary to determine if liver and spleen macrophages will degrade these IONs, or eventually exocytose both the degraded and intact ones.
Naghibi Beidokhti, Hamid Reza; Ghaffarzadegan, Reza; Mirzakhanlouei, Sasan; Ghazizadeh, Leila; Dorkoosh, Farid Abedin
2017-01-01
The objective of this study was to investigate the combined influence of independent variables in the preparation of folic acid-chitosan-methotrexate nanoparticles (FA-Chi-MTX NPs). These NPs were designed and prepared for targeted drug delivery in tumor. The NPs of each batch were prepared by coaxial electrospray atomization method and evaluated for particle size (PS) and particle size distribution (PSD). The independent variables were selected to be concentration of FA-chitosan, ratio of shell solution flow rate to core solution flow rate, and applied voltage. The process design of experiments (DOE) was obtained with three factors in three levels by Design expert software. Box-Behnken design was used to select 15 batches of experiments randomly. The chemical structure of FA-chitosan was examined by FTIR. The NPs of each batch were collected separately, and morphologies of NPs were investigated by field emission scanning electron microscope (FE-SEM). The captured pictures of all batches were analyzed by ImageJ software. Mean PS and PSD were calculated for each batch. Polynomial equation was produced for each response. The FE-SEM results showed the mean diameter of the core-shell NPs was around 304 nm, and nearly 30% of the produced NPs are in the desirable range. Optimum formulations were selected. The validation of DOE optimization results showed errors around 2.5 and 2.3% for PS and PSD, respectively. Moreover, the feasibility of using prepared NPs to target tumor extracellular pH was shown, as drug release was greater in the pH of endosome (acidic medium). Finally, our results proved that FA-Chi-MTX NPs were active against the human epithelial cervical cancer (HeLa) cells.
Li, Ruili; Vannitamby, Amanda; Zhang, Jian-Guo; Fehmel, Emma L; Southwell, Bridget R; Hutson, John M
2015-12-01
In cryptorchidism perinatal failure to switch off Oct4, a germ cell (GC) marker, may lead to carcinoma in situ. We aimed to analyze Oct4 expression during mouse gonocyte transformation into spermatogonial stem cells (SSC). Testes from OG2 (Oct4-promoter driven eGFP) mice at embryonic day (E) 17 and postnatal day P0-10 underwent immunohistochemistry and immunoblotting. Antibodies against MVH, AMH, Ki67, and c-Kit were visualized by confocal microscopy. Numbers of Oct4-GFP(+) GC and Oct4-GFP(-) GC/tubule were counted using ImageJ. Data were analyzed using nonparametric one-way ANOVA. GC from E17-P4 were Oct4-GFP(+). Numbers of Oct4-GFP(-) GC/tubule increased from P6-10, whereas Oct4-GFP(+) GC/tubule numbers remained similar between P6 and P10. Sertoli cells proliferated from E17-P10, whereas GC only proliferated from P2. Gonocytes (Oct4-GFP(+)/c-Kit(-)) central in tubules migrated to the basement membrane to become prospermatogonia (Oct4-GFP(+)/c-Kit(-)) and then SSC (Oct4-GFP(+)/c-Kit(+)) from day 4 and further developed into Oct4-GFP(-)/c-Kit(+) at P6. In Oct4-GFP mice both centrally located gonocytes and prospermatogonia located at the tubular basement membrane were Oct4-GFP(+)/c-Kit(-) before further developing into SSC (Oct4-GFP(+)/c-Kit(+)). This indicates that Oct4 is important in gonocyte transformation into SSC. Understanding this process will aid GC tumor diagnostics and fertility potential in boys with UDT undergoing orchidopexy. Copyright © 2015 Elsevier Inc. All rights reserved.
Craniofacial structure alterations of foetuses from folic acid deficient pregnant mice.
Maldonado, Estela; López, Yamila; Herrera, Manuel; Martínez-Sanz, Elena; Martínez-Álvarez, Concepción; Pérez-Miguelsanz, Juliana
2018-03-28
Craniofacial development in mammals is a complex process that involves a coordinated series of molecular and morphogenetic events. Folic acid (FA) deficiency has historically been associated with congenital spinal cord malformations, but the effect that a maternal diet deficient in FA has on the development of other structures has been poorly explored. In the present study, the objective was to describe and quantify the alterations of craniofacial structures presented in mouse foetuses from dams fed a FA deficient (FAD) diet compared with controls that were given a regular maternal diet. E17 mouse foetuses were removed from dams that were fed with a control diet or with a FAD diet for several weeks. Foetuses with maternal FAD diets were selected for the study when they showed an altered tongue or mandible. Histological sections were used to quantify the dimensions of the head, tongue, mandibular bone and masseter muscle areas using ImageJ software. The muscles of the tongue, suprahyoid muscles, lingual septum, submandibular ducts, and lingual arteries were also analysed. The heads of malformed foetuses were smaller than the heads of the controls, and they showed different types of malformations: microglossia with micrognathia (some of which were combined with cleft palate) and aglossia with either micrognathia or agnathia. Lingual and suprahyoid muscles were affected in different forms and degrees. We also found alterations in the lingual arteries and in the ducts of the submandibular glands. Summarised we can state that pharyngeal arches-derived structures were affected, and the main malformations observed corroborate the vulnerability of cranial neural crest cells to FA deficiency. The present study reveals alterations in the development of craniofacial structures in FAD foetuses. This study provides a new focus for the role of FA during embryological development. Copyright © 2018 Elsevier GmbH. All rights reserved.
Gomes, Marcus Vinícius de Matos; Manfredo, Marcelo Henrique; Toffoli, Leandro Vaz; Castro-Alves, Daniellen Christine; do Nascimento, Lucas Magnoni; da Silva, Wyllian Rafael; Kashimoto, Roberto Kiyoshi; Rodrigues, Gelson Marcos; Estrada, Viviane Batista; Andraus, Rodrigo Antonio; Pelosi, Gislaine Garcia
2016-09-01
The use of light emitting diodes (LED) as a therapeutic resource for wound healing has increased over the last years; however, little is still known about the molecular pathways associated to LED exposure. In the present study, we verified the effects of LED therapy on DNA methylation and expression of the DNA methyltransferase (Dnmt) genes, Dnmt1 and Dnmt3a, in an in vivo model of epithelial wound healing. Male Wistar rats were submitted to epithelial excision in the dorsal region and subsequently distributed within the experimental groups: group 1, animals that received irradiation of 0.8 J/cm(2) of LED (604 nm); group 2, animals that received 1.6 J/cm(2) of LED (604 nm); control (CTL), animals not submitted to therapeutic intervention. LED applications were performed during 7 days, and tissues from the periphery of the wound area were obtained for molecular analysis. The Image-J software was used for analysis of the wound area. DNA methylation was evaluated by ELISA-based method and gene expressions were quantified by real-time PCR. Decrease on global DNA methylation profile was observed in all experimental groups (CTL, 1, and 2) revealing the participation of DNA methylation in the healing process. Significant decrease in the wound area accompanied by increase in the Dnmt3a expression was associated to group 2. Based on our findings, we propose that DNA methylation is an important molecular mechanism associated to wound healing and that irradiation with 1.6 J/cm(2) of LED evokes an increase in the expression of the Dnmt3a that might associates to the efficiency of the epithelial wound healing.
NASA Astrophysics Data System (ADS)
Iskandar, Maria Emil
Magnesium (Mg) alloys, a novel class of degradable, metallic biomaterials, have attracted growing interest as a promising alternative for medical implant and device applications due to their advantageous mechanical and biological properties. Moreover, Mg is biodegradable in the physiological environments. However, the major obstacle for Mg to be used as medical implants is its rapid degradation in physiological fluids. Therefore, the present key challenge lies in controlling Mg degradation rate in the physiological environment. The objective of this study was to develop a nanostructured-hydroxyapatite (nHA) coating on polished Mg implants to control the degradation and bone tissue integration of the implants. The nHA coatings were deposited on Mg using the Spire's patented TPA process to moderate the aggressive degradation of Mg and to improve quick osteointegration between Mg and natural bone. Nanostructured-HA coatings mimic the nanostructure and chemistry of natural bone, which will provide a desirable environment for bone tissue regeneration. Surface morphology, element compositions, and crystal structures were characterized using scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), and x-ray diffractometry (XRD), respectively. SEM images of the deposited nHA-coating was analyzed using ImageJ's quantitative image analysis tool, to determine the nHA-coating particle size and thickness. The degradation of nHA-coated and non-coated Mg samples was investigated by incubating samples in phosphate buffered saline (PBS) and revised simulated body fluid (r-SBF), under standard cell culture conditions. To mimic the in vivo cell response in the physiological environment, rat bone marrow stromal cells (BMSC) were harvested and cultured with nHA-coated and non-coated polished Mg samples to determine cytocompatibilty. The degradation results suggested that the nanocoatings positively mediated Mg degradation. It can therefore be concluded that nHA-coatings show promise for controlling the biodegradation of Mg-based orthopedic implants and devices. Cell studies indicated significantly improved BMSC adhesion on the surfaces of the nHA-coated and non-coated Mg samples, in comparison to the cells surrounding the Mg samples. These results indicated that the nHA-coated and non-coated Mg samples promote cell activity on the surface. However, cell experiments must be repeated on a larger number of samples with extensive short and long term cell studies, to achieve more verifiable results.
Khramtsov, Pavel; Bochkova, Maria; Timganova, Valeria; Zamorina, Svetlana; Rayev, Mikhail
2017-06-01
A dot immunoassay for simultaneous semiquantitative detection of IgG against tetanus toxoid (Ttx) and diphtheria toxoid (Dtx) and qualitative detection of anti-Bordetella pertussis IgGs in human blood serum using carbon nanoparticles functionalized with streptococcal protein G was developed. Inactivated B. pertussis cells in suspension form were used as an antigen in the immunoassay. Pertussis, tetanus, and diphtheria antigens were separately spotted onto nitrocellulose strips, and then the immunostrips were successively incubated with blood sera and a suspension of carbon nanoparticles. The immunostrips were then scanned with a flatbed scanner, and the images obtained were processed with ImageJ. One hundred fifty-five venous blood serum samples from children vaccinated with diphtheria, tetanus, and whole-cell pertussis (DTwP) vaccine were tested in comparison with a conventional ELISA and agglutination test. The total time required for analysis of 32 serum samples was less than 3 h. Comparison between the results of the dot immunoassay and the corresponding ELISA/agglutination test revealed a high level of agreement (Cohen's kappa between 0.765 and 0.813). The lower limit of quantification was 0.06 IU/ml for anti-Ttx and anti-Dtx. The intra-assay coefficients of variation were less than 15% for anti-Ttx and anti-Dtx and less than 10% for anti-pertussis. The diagnostic sensitivity of detection of the antibody protection level was 93.5% for anti-Ttx [95% confidence interval (CI) 83.5-97.9%], 92.4% for anti-Dtx (95% CI 80.9297.5%), and 90.2% for anti-pertussis (95% CI 75.9-96.8%). The diagnostic specificity was 90.9% for anti-Ttx (95% CI 57.1-99.5%), 85% for anti-Dtx (95% CI 61.1-96.0%), and 89.3% for anti-pertussis (95%CI 80.8-94.5%). The dot immunoassay developed does not require expensive reading equipment, and allows detection of antibodies against three antigens in a single analysis. The immunostrips can be stored for a long time without changes in the coloration of the spots. Graphical Abstract The assay procedure. BC Bordetella pertussis cell suspension, CNP carbon nanoparticle, Dtx diphtheria toxoid, Ttx tetanus toxoid.
Mahasantipiya, Phattaranant May; Pramojanee, Sakarat; Thaiupathump, Trasapong
2013-12-01
This study was performed to determine the relationship between the stage of tooth eruption (both vertical and mesio-angular) and chronological age. Indirect digital panoramic radiographs were used to measure the distances from the dentinoenamel junction (DEJ) of the second molars to the occlusal plane of the second molar teeth and of the adjacent third molars in 264 Thai males and 437 Thai females using ImageJ software. The ratio of those distances was calculated by patient age, and the correlation coefficient of the ratio of the third molar length to the second molar length was calculated. The correlation between the height of the vertically erupted upper third molar teeth and age was at the intermediate level. The age range of ≥15 to <16 years was noted to be the range in which the correlation between the chronological age determined from the eruptional height and actual chronological age was statistically significant. The mean age of the female subjects, in which the position of the right upper third molar teeth was at or above the DEJ of the adjacent second molar but below one half of its coronal height was 19.9±2.6 years. That for the left side was 20.2±2.7 years. The mean ages of the male subjects were 20.1±3.3 years and 19.8±2.7 years for the right and left sides, respectively. It might be possible to predict chronological age from the eruption height of the wisdom teeth.
Nakano, Eri; Hata, Masayuki; Oishi, Akio; Miyamoto, Kazuaki; Uji, Akihito; Fujimoto, Masahiro; Miyata, Manabu; Yoshimura, Nagahisa
2016-08-01
The purpose was to investigate an objective and quantitative method to estimate the redness of the optic disc neuroretinal rim, and to determine the usefulness of this method to differentiate compressive optic neuropathy (CON) from glaucomatous optic neuropathy (GON). In our study there were 126 eyes: 40 with CON, 40 with normal tension glaucoma (NTG), and 46 normal eyes (NOR). Digital color fundus photographs were assessed for the redness of disc rim color using ImageJ software. We separately measured the intensity of red, green, and blue pixels from RGB images. Three disc color indices (DCIs), which indicate the redness intensity, were calculated through existing formulas. All three DCIs of CON were significantly smaller than those of NOR (P < 0.001). In addition, when compared with NTG, DCIs were also significantly smaller in CON (P < 0.05). A comparison of mild CON and mild NTG (mean deviation (MD) > -6 dB), in which the extent of retinal nerve fiber layer thinning is comparable, the DCIs of mild CON were significantly smaller than those of mild NTG (P < 0.05). In contrast, DCIs did not differ between moderate-to-severe stages of CON and NTG (MD ≤ -6 dB), though the retinal nerve fibers of CON were more severely damaged than those of NTG. To differentiate between mild CON and mild NTG, all AUROCs for the three DCIs were above 0.700. A quantitative and objective assessment of optic disc color was useful in differentiating early-stage CON from GON and NOR.
Kuswandi, Bambang; Irmawati, Titi; Hidayat, Moch Amrun; Jayus; Ahmad, Musa
2014-01-01
A simple visual ethanol biosensor based on alcohol oxidase (AOX) immobilised onto polyaniline (PANI) film for halal verification of fermented beverage samples is described. This biosensor responds to ethanol via a colour change from green to blue, due to the enzymatic reaction of ethanol that produces acetaldehyde and hydrogen peroxide, when the latter oxidizes the PANI film. The procedure to obtain this biosensor consists of the immobilization of AOX onto PANI film by adsorption. For the immobilisation, an AOX solution is deposited on the PANI film and left at room temperature until dried (30 min). The biosensor was constructed as a dip stick for visual and simple use. The colour changes of the films have been scanned and analysed using image analysis software (i.e., ImageJ) to study the characteristics of the biosensor's response toward ethanol. The biosensor has a linear response in an ethanol concentration range of 0.01%–0.8%, with a correlation coefficient (r) of 0.996. The limit detection of the biosensor was 0.001%, with reproducibility (RSD) of 1.6% and a life time up to seven weeks when stored at 4 °C. The biosensor provides accurate results for ethanol determination in fermented drinks and was in good agreement with the standard method (gas chromatography) results. Thus, the biosensor could be used as a simple visual method for ethanol determination in fermented beverage samples that can be useful for Muslim community for halal verification. PMID:24473284
Tekieh, Elaheh; Riahi, Esmail; Kazemi, Masoomeh; Sahraei, Hedayat; Tavakoli, Hassan; Aliyary, Hamed; Hajinasrollah, Mostafa; Salehi, Maryam; Meftahi, Gholamhossein; Saberi, Mehdi
2017-08-01
In the present study the effect of stress on monkeys that had learned to retrieve food from a five-chamber receptacle, as well as the relationship between their behavior and the serum cortisol and epinephrine levels and relative size of the amygdala was evaluated. Six male rhesus monkeys were individually given access to the food reward orderly. They could easily retrieve the rewards from all chambers except for the chamber 4, which a brief, mild electric shock (3 V) was delivered to them upon touching the chamber's interior. The coping behaviors were video-recorded and analyzed offline. Baseline serum cortisol and epinephrine levels were measured before the experiments using monkey enzyme-linked immunosorbent assay kit. One week after the behavioral experiment, the monkeys' brains were scanned using magnetic resonance imaging under general anesthesia. The cross-sectional area of the left amygdala in sagittal plane relative to the area of the whole brain in the same slice was evaluated by the planimetric method using ImageJ software. Exposure to the distressing condition caused different behavioral responses. Monkeys with higher baseline levels of serum cortisol and epinephrine and larger amygdala behaved more violently in the face of stress, indicating adopting emotion-focused stress-coping strategies. Conversely, those with low plasma epinephrine, moderate cortisol, and smaller amygdala showed perseverative behavior, indicating a problem-focused coping style. In dealing with the same stress, different responses might be observed from nonhuman primates according to their cortisol and epinephrine levels as well as their amygdala dimensions.
Farah, Nicolas; Francis, Ziad; Abboud, Marie
2014-09-01
We explore in our study the effects of electrons and X-rays irradiations on the newest version of the Gafchromic EBT3 film. Experiments are performed using the Varian "TrueBeam 1.6" medical accelerator delivering 6 MV X-ray photons and 6 MeV electron beams as desired. The main interest is to compare the responses of EBT3 films exposed to two separate beams of electrons and photons, for radiation doses ranging up to 500 cGy. The analysis is done on a flatbed EPSON 10000 XL scanner and cross checked on a HP Scanjet 4850 scanner. Both scanners are used in reflection mode taking into account landscape and portrait scanning positions. After thorough verifications, the reflective scanning method can be used on EBT3 as an economic alternative to the transmission method which was also one of the goals of this study. A comparison is also done between single scan configuration including all samples in a single A4 (HP) or A3 (EPSON) format area and multiple scan procedure where each sample is scanned separately on its own. The images analyses are done using the ImageJ software. Results show significant influence of the scanning configuration but no significant differences between electron and photon irradiations for both single and multiple scan configurations. In conclusion, the film provides a reliable relative dose measurement method for electrons and photons irradiations in the medical field applications. Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Endodontic filling removal procedure: an ex vivo comparative study between two rotary techniques.
Vale, Mônica Sampaio do; Moreno, Melinna dos Santos; Silva, Priscila Macêdo França da; Botelho, Thereza Cristina Farias
2013-01-01
In this study, we compared the ex vivo removal capacity of two endodontic rotary techniques and determined whether there was a significant quantitative difference in residual material when comparing root thirds. Forty extracted molars were used. The palatal roots were selected, and the canals were prepared using a step-back technique and filled using a lateral condensation technique with gutta-percha points and Endofill sealer. After two weeks of storage in a 0.9% saline solution at 37 ºC in an oven, the specimens were divided into 2 groups of 20, with group 1 samples subjected to Gates-Glidden drills and group 2 samples subjected to the ProTaper retreatment System. Hedstroem files and eucalyptol solvent were used in both groups to complete the removal procedure. Then, the roots thirds were radiographed and the images were submitted to the NIH ImageJ program to measure the residual filling material in mm. Each root third was related to the total area of the root canals. The data were analyzed using Student's t test. There was a statistically significant difference between the two techniques as more filling material was removed by technique 2 (ProTaper) than technique 1 (Gates-Glidden drills, p < 0.05). The apical third had a greater amount of residual filling material than the cervical and middle thirds, and the difference was statistically significant (p < 0.05). None of the selected techniques removed all filling material, and the material was most difficult to remove from the apical third. The ProTaper files removed more material than the Gates-Glidden drills.
Sabel, Nina; Johansson, Carina; Kühnisch, Jan; Robertson, Agneta; Steiniger, Frank; Norén, Jörgen G; Klingberg, Gunilla; Nietzsche, Sandor
2008-10-01
The neonatal line (NNL) is in principle found in all primary teeth and the line represents the time of birth. Earlier findings of the appearance of the NNL in light microscope and in microradiographs have shown not only changes in the prism direction of the enamel, but that the NNL has a hypomineralized character. The neonatal line was analyzed in un-decalcified sections of primary lower and central incisors, collected from individuals of different ages utilizing polarized light microscopy, microradiography, scanning electron microscopy (SEM) and X-ray analysis (XRMA). In polarized light the NNL appeared to have a more porous structure than the enamel in general. The appearance of the NNL as a dark line in microradiographs is interpreted as the NNL being less mineralized than neighbouring enamel. Analysis with ImageJ visualized the reduction of the amount of grey value, indicating that the NNL is less mineralized. Analysis of the NNL in SEM showed a reduction of the diameter of enamel prisms, the more narrow diameters continued through the postnatal enamel. A change of the growth direction of the prisms was also observed at the NNL. In a three-dimensional image the NNL appeared as a grove, however, in non-etched enamel no grove was seen. The elemental analyses with XRMA showed no marked changes in the content of C, Ca, P, N, O or S in the area around the NNL. The NNL is an optical phenomenon due to alterations in height, and degree of mineralization of the enamel prisms.
Quantifying Dynamic Deformity After Dual Plane Breast Augmentation.
Cheffe, Marcelo Recondo; Valentini, Jorge Diego; Collares, Marcus Vinicius Martins; Piccinini, Pedro Salomão; da Silva, Jefferson Luis Braga
2018-06-01
Dynamic breast deformity (DBD) is characterized by visible distortion and deformity of the breast due to contraction of the pectoralis major muscle after submuscular breast augmentation; fortunately, in most cases, this is not a clinically significant complaint from patients. The purpose of this study is to present a simple method for objectively measuring DBD in patients submitted to dual plane breast augmentation (DPBA). We studied 32 women, between 18 and 50 years old, who underwent primary DPBA with at least 1 year of follow-up. Anthropometric landmarks of the breast were marked, creating linear segments. Standardized photographs were obtained both during no pectoralis contraction (NPC) and during maximum pectoralis muscle contraction (MPC); measurements of the linear segments were taken through ImageJ imaging software, and both groups were compared. We found statistically significant differences in all analyzed segments when comparing measurements of the breasts during NPC and MPC (p < 0.001). Our study proposes a novel, standardized method for measuring DBD after DPBA. This technique is reproducible, allowing for objective quantification of the deformity in any patient, which can be valuable for both patients and surgeons, as it allows for a more thorough discussion on DBD, both pre- and postoperatively, and may help both patients and surgeons to make more informed decisions regarding potential animation deformities after breast augmentation. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
NASA Astrophysics Data System (ADS)
Somasundaram, Elanchezhian; Kaufman, Robert; Brady, Samuel
2017-03-01
The development of a random forests machine learning technique is presented for fully-automated neck, chest, abdomen, and pelvis tissue segmentation of CT images using Trainable WEKA (Waikato Environment for Knowledge Analysis) Segmentation (TWS) plugin of FIJI (ImageJ, NIH). The use of a single classifier model to segment six tissue classes (lung, fat, muscle, solid organ, blood/contrast agent, bone) in the CT images is studied. An automated unbiased scheme to sample pixels from the training images and generate a balanced training dataset over the seven classes is also developed. Two independent training datasets are generated from a pool of 4 adult (>55 kg) and 3 pediatric patients (<=55 kg) with 7 manually contoured slices for each patient. Classifier training investigated 28 image filters comprising a total of 272 features. Highly correlated and insignificant features are eliminated using Correlated Feature Subset (CFS) selection with Best First Search (BFS) algorithms in WEKA. The 2 training models (from the 2 training datasets) had 74 and 71 input training features, respectively. The study also investigated the effect of varying the number of trees (25, 50, 100, and 200) in the random forest algorithm. The performance of the 2 classifier models are evaluated on inter-patient intra-slice, intrapatient inter-slice and inter-patient inter-slice test datasets. The Dice similarity coefficients (DSC) and confusion matrices are used to understand the performance of the classifiers across the tissue segments. The effect of number of features in the training input on the performance of the classifiers for tissue classes with less than optimal DSC values is also studied. The average DSC values for the two training models on the inter-patient intra-slice test data are: 0.98, 0.89, 0.87, 0.79, 0.68, and 0.84, for lung, fat, muscle, solid organ, blood/contrast agent, and bone, respectively. The study demonstrated that a robust segmentation accuracy for lung, muscle and fat tissue classes. For solid-organ, blood/contrast and bone, the performance of the segmentation pipeline improved significantly by using the advanced capabilities of WEKA. However, further improvements are needed to reduce the noise in the segmentation.
Use of a Binocular Optical Coherence Tomography System to Evaluate Strabismus in Primary Position.
Chopra, Reena; Mulholland, Pádraig J; Tailor, Vijay K; Anderson, Roger S; Keane, Pearse A
2018-05-31
Current clinical methods for assessing strabismus can be prone to error. Binocular optical coherence tomography (OCT) has the potential to assess and quantify strabismus objectively and in an automated manner. To evaluate the use of a binocular OCT prototype to assess the presence and size of strabismus. Fifteen participants with strabismus were recruited in 2016 as part of the EASE study from Moorfields Eye Hospital National Health Service Foundation Trust, London, England, and 15 healthy volunteers underwent automated anterior segment imaging using the binocular OCT prototype. All participants had an orthoptic assessment, including alternating prism cover test (APCT), before undergoing imaging. Simultaneously acquired pairs of OCT images, captured with 1 eye fixating, were analyzed using ImageJ (National Institutes of Health) to assess the presence and angle of strabismus. The direction and size of strabismus measured using binocular OCT was compared with that found using APCT. The median age for participants with strabismus was 55 years (interquartile range [IQR], 33-66.5 years) and for the healthy group, 50 years (IQR, 41-59 years); 15 participants (50%) were women, and 25 participants (83.3%) were white. The median magnitude of horizontal deviation was 20∆ (IQR, 13-35∆) and for vertical deviation, 3∆ (IQR, 0-5∆). Binocular OCT imaging correctly revealed the type and direction of the deviation in all 15 participants with strabismus, including horizontal and vertical deviations. The APCT and OCT measurements were strongly correlated for the horizontal (Pearson r = 0.85; 95% CI, 0.60-0.95; P < .001) and vertical (r = 0.89; 95% CI, 0.69-0.96; P < .001) deviations. In the healthy cohort, 9 of 15 participants (60%) had a latent horizontal deviation on APCT results (median magnitude 2∆, range 2-4∆). Six (40%) had orthophoria. Horizontal deviations were observed on OCT imaging results in 12 of the 15 participants (80%), and a vertical deviation was visible in 1 participant (6.7%). These findings suggest that binocular anterior segment OCT imaging can provide clinicians with a precise measurement of strabismus. The prototype can potentially incorporate several binocular vision tests that will provide quantitative data for the assessment, diagnosis, and monitoring of ocular misalignments.
X-ray Mapping of Terrestrial and Extraterrestrial Materials Using the Electron Microprobe
NASA Technical Reports Server (NTRS)
Carpenter, P.
2006-01-01
Lunar samples returned from the Apollo program motivated development of the Bence-Albee algorithm for the rapid and accurate analysis of lunar materials, and established interlaboratory comparability through its common use. In the analysis of mineral and rock fragments it became necessary to combine micro- and macroscopic analysis by coupling electron-probe microanalysis (EPMA) with automated stage point counting. A coarse grid that included several thousand points was used, and initially wavelength-dispersive (WDS) and later energydispersive (EDS) data were acquired at discrete stage points using approx. 5 sec count times. A approx 50 micrometer beam diameter was used for WDS and up to 500 micrometer beam diameter for EDS analysis. Average analyses of discretely sampled phases were coupled with the point count data to calculate the bulk composition using matrix algebra. Use of a defocused beam resulted in a contribution from multiple phases to each analytical point, and the analytical data were deconvolved relative to end-member phase chemistry on the fly. Impressive agreement was obtained between WDS and EDS measurements as well as comparison with bulk chemistry obtained by other methods. In the 30 years since these methods were developed, significant improvements in EPMA automation and computer processing have taken place. Digital beam control allows routine collection of x-ray maps by EDS, and stage mapping for WDS is conducted continuously at slew speed and incrementally by sampling at discrete points. Digital pulse processing in EDS systems has significantly increased the throughput for EDS mapping, and the ongoing development of Si-drift detector systems promises mapping capabilities rivaling WDS systems. Spectrum imaging allows a data cube of EDS spectra to be acquired and sophisticated processing of the original data is possible using matrix algebra techniques. The study of lunar and meteoritic materials includes the need to conveniently: (1) Characterize the sample at microscopic and macroscopic scales with relatively high sensitivity, (2) Determine the modal abundance of minerals, and (3) Identify and relocate discrete features of interest in terms of size and chemistry. The coupled substitution of cations in minerals can result in significant variation in mineral chemistry, but at similar average Z, leading to poor backscattered-electron (BSE) contrast discrimination of mineralogy. It is necessary to discriminate phase chemistry at both the trace element level and the major element level. To date, the WDS of microprobe systems is preferred for mapping due to high throughput and the ability to obtain the necessary intensity to discriminate phases at both trace and major element concentrations. It is desirable to produce fully quantitative compositional maps of geological materials, which requires the acquisition of k-ratio maps that are background and dead-time corrected, and which have been corrected by phi(delta z> or an equivalent algorithm at each pixel. To date, turnkey systems do not allow the acquisition of k-ratio maps and the rigorous correction in this manner. X-ray maps of a chondrule from the Ourique meteorite, and a comb-layered xenolith from the San Francisco volcanic field, have been analyzed and processed to extract phase information. The Ourique meteorite presents a challenge due to relatively low BSE contrast, and has been studied using spectrum imaging. X-ray maps for Si, Mg, and FeK(alpha) were used to produce RGB images. The xenolith sample contains sector-zoned augite, olivine, plagioclase, and basaltic glass. X-ray maps were processed using Lispix and ImageJ software to produce mineral phase maps. The x-ray maps for Mg, Ca, and Ti were used with traceback to generate binary images that were converted to RGB images. These approaches are successful in discriminating phases, but it is desirable to achieve the methods that were used on lunar samples 30 years ago on current microprobe systems. Curnt research includes x-ray mapping analysis of the Dalgety Downs chondrite by micro x-ray fluorescence and spectrum imaging, in collaboration with Kenny Witherspoon of IXRF Systems and Dale Newbury of NIST.
Glottic airway gain after 'suture arytenoid laterofixation' in bilateral vocal cord paralysis.
Korkmaz, Mehmet Hakan; Bayır, Ömer; Tatar, Emel Çadallı; Saylam, Güleser; Öcal, Bülent; Keseroğlu, Kemal; Özdek, Ali
2015-09-01
This method is an easy, non-expensive, and effective technique in bilateral vocal cord paralysis to improve glottic airway and clinical performance. To evaluate the effectiveness of 'suture arytenoid laterofixation' surgery in bilateral vocal cord paralysis. A retrospective analysis of patients' medical history undergoing 'suture arytenoid laterofixation' surgery for bilateral vocal cord paralysis. This technique was applied under general anesthesia with both microlaryngoscopy and video-monitoring. Two 16 g needles and one 1/0 nylon thread were used for the procedure with 1 cm skin incision; no tracheotomy or tissue excision was required. Pre-post-operative photographs of the glottic region were taken from the endoscopic records, and the areas of rima glottis openings were calculated with the Image-J programme. Forty-seven patients were analyzed. The mean pre-post-operative rima glottis areas were 1.11 ± 0.56 and 2.24 ± 0.93 mm(2), respectively (p < 0.001). Five patients with previous tracheotomy were decannulated within a few days after the operation. In three patients, mild complications developed in the early post-operative period (two laryngeal edemas, one submucosal hematoma). Tracheotomy was performed to only one pregnant patient in the post-operative first day. None of the patients had granulation formation or synechia.
NASA Astrophysics Data System (ADS)
Zaraska, Leszek; Stępniowski, Wojciech J.; Sulka, Grzegorz D.; Ciepiela, Eryk; Jaskuła, Marian
2014-02-01
Anodic porous alumina layers were fabricated by a two-step self-organized anodization in 0.3 M oxalic acid under various anodizing potentials ranging from 30 to 60 V at two different temperatures (10 and 17 ∘C). The effect of anodizing conditions on structural features and pore arrangement of AAO was investigated in detail by using the dedicated executable publication combined with ImageJ software. With increasing anodizing potential, a linear increase of the average pore diameter, interpore distance, wall thickness and barrier layer thickness, as well as a decrease of the pore density, were observed. In addition, the higher pore diameter and porosity values were obtained for samples anodized at the elevated temperature, independently of the anodizing potential. A degree of pore order was investigated on the basis of Delaunay triangulations (defect maps) and calculation of pair distribution or angle distribution functions (PDF or ADF), respectively. All methods confirmed that in order to obtain nanoporous alumina with the best, hexagonal pore arrangement, the potential of 40 V should be applied during anodization. It was confirmed that the dedicated executable publication can be used to a fast and complex analysis of nanopore arrangement and structural features of nanoporous oxide layers.
Microstructural behavior of iron and bismuth added Sn-1Ag-Cu solder under elevated temperature aging
NASA Astrophysics Data System (ADS)
Ali, Bakhtiar; Sabri, Mohd Faizul Mohd; Jauhari, Iswadi
2016-07-01
An extensive study was done to investigate the microstructural behavior of iron (Fe) and bismuth (Bi) added Sn-1Ag-0.5Cu (SAC105) under severe thermal aging conditions. The isothermal aging was done at 200 °C for 100 h, 200 h, and 300 h. Optical microscopy with cross-polarized light revealed that the grain size significantly reduces with Fe/Bi addition to the base alloy SAC105 and remains literally the same after thermal aging. The micrographs of field emission scanning electron microscopy (FESEM) with backscattered electron detector and their further analysis via imageJ software indicated that Fe/Bi added SAC105 showed a significant reduction in the IMCs size (Ag3Sn and Cu6Sn5), especially the Cu6Sn5 IMCs, as well as β-Sn matrix and a refinement in the microstructure, which is due to the presence of Bi in the alloys. Moreover, their microstructure remains much more stable under severe thermal aging conditions, which is because of the presence of both Fe and Bi in the alloy. The microstructural behavior suggests that Fe/Bi modified SAC105 would have much improved reliability under severe thermal environments. These modified alloys also have relatively low melting temperature and low cost.
Gronwald, John W; Bucciarelli, Bruna
2013-08-30
In previous research, two alfalfa clonal lines (252 and 1283) were identified that exhibited environmentally stable differences in stem cell walls. Compared with stems of 1283, stems of 252 have a higher cell wall concentration and greater amounts of lignin and cellulose but reduced levels of pectic sugar residues. These results suggest greater deposition of secondary xylem and a reduction in pith in stems of 252 compared with 1283. The stem morphology and anatomy of first-cut and second-cut harvests of field-grown 1283 and 252 were examined. For both harvests, stems of 1283 were thicker and had a higher leaf/stem ratio compared with stems of 252. Stem cross-sections of both genotypes were stained for lignin, and the proportions of stem area that were pith and secondary xylem were measured using ImageJ. Stems of 252 exhibited greater deposition of secondary xylem and a reduction in pith proportion compared with stems of 1283 for the first-cut harvest, but this difference was not statistically significant for the second-cut harvest. The results indicate that the proportions of secondary xylem and pith are not environmentally stable in these two genotypes and hence cannot be the sole basis for the differences in cell wall concentration/composition. © 2012 Society of Chemical Industry.
Aluminum Exposure from Parenteral Nutrition: Early Bile Canaliculus Changes of the Hepatocyte.
Hall, Amanda R; Le, Ha; Arnold, Chris; Brunton, Janet; Bertolo, Robert; Miller, Grant G; Zello, Gordon A; Sergi, Consolato
2018-06-04
Background: Neonates on long-term parenteral nutrition (PN) may develop parenteral nutrition-associated liver disease (PNALD). Aluminum (Al) is a known contaminant of infant PN, and we hypothesize that it substantially contributes to PNALD. In this study, we aim to assess the impact of Al on hepatocytes in a piglet model. Methods: We conducted a randomized control trial using a Yucatan piglet PN model. Piglets, aged 3⁻6 days, were placed into two groups. The high Al group ( n = 8) received PN with 63 µg/kg/day of Al, while the low Al group ( n = 7) received PN with 24 µg/kg/day of Al. Serum samples for total bile acids (TBA) were collected over two weeks, and liver tissue was obtained at the end of the experiment. Bile canaliculus morphometry were studied by transmission electron microscopy (TEM) and ImageJ software analysis. Results: The canalicular space was smaller and the microvilli were shorter in the high Al group than in the low Al group. There was no difference in the TBA between the groups. Conclusions: Al causes structural changes in the hepatocytes despite unaltered serum bile acids. High Al in PN is associated with short microvilli, which could decrease the functional excretion area of the hepatocytes and impair bile flow.
Kokornaczyk, Maria Olga; Baumgartner, Stephan; Betti, Lucietta
2016-05-01
Polycrystalline structures formed inside evaporating droplets of different biological fluids have been shown sensitive towards various influences, including ultra high dilutions (UHDs), representing so a new approach potentially useful for basic research in homeopathy. In the present study we tested on a wheat seed model Zincum metallicum 30c efficacy versus lactose 30c and water. Stressed and non-stressed wheat seeds were watered with the three treatments. Seed-leakage droplets were evaporated and the polycrystalline structures formed inside the droplet residues were analyzed for their local connected fractal dimensions (LCFDs) (measure of complexity) using the software ImageJ. We have found significant differences in LCFD values of polycrystalline structures obtained from stressed seeds following the treatments (p<0.0001); Zincum metallicum 30c lowered the structures' complexity compared to lactose 30c and water. In non-stressed seeds no significant differences were found. The droplet evaporation method (DEM) might represent a potentially useful tool in basic research in homeopathy. Furthermore our results suggest a sensitization of the stressed model towards the treatment action, which is conforming to previous findings. Copyright © 2015 The Faculty of Homeopathy. Published by Elsevier Ltd. All rights reserved.
A paired-laser photogrammetric method for in situ length measurement of benthic fishes
Rizzo, Austin A.; Welsh, Stuart A.; Thompson, Patricia A.
2017-01-01
Photogrammetry, a technique to obtain measurements from photographs, may be a valid method for measuring lengths of rare, threatened, or endangered species. Photogrammetric methods of measurement are nonintrusive and reduce the possibility of physical damage or physiological stress associated with the capture and handling of individuals. We evaluated precision and accuracy of photogrammetric length measurements relative to board measurements of Greenside Darters Etheostoma blennioides and Variegate Darters E. variatum in an aquarium and applied photogrammetry in a field study of the Diamond Darter Crystallaria cincotta, a federally listed endangered species. Digital photographs were taken of each individual using a waterproof camera equipped with two parallel lasers. Photogrammetric length measurements were digitized with ImageJ software. Agreement between board and photogrammetric measurements were high for Greenside and Variegate darters. The magnitude of differences was small between direct and photogrammetric measurements, ranging from 0.6% to 3.1%, depending on the species measured and the type of measurement taken. These results support photogrammetry as a useful method for obtaining length measurements of benthic stream fishes. Photogrammetric methods allowed for length measurements and an assessment of length frequency of 199 Diamond Darters, informative data for management that could not be collected with conventional measuring-board methods.
A paper-based Colorimetric Indicator Label using Natural Dye for Monitoring Shrimp Spoilage
NASA Astrophysics Data System (ADS)
Listyarini, A.; Sholihah, W.; Imawan, C.
2018-05-01
Shrimp is a type of perishable food. This study developed a simple indicator label using colorimetric method for monitoring shrimp freshness. This indicator label was made from natural dye extract of Ruellia simplex flowers which immobilized on cellulose paper by dip coating method. The indicator labels were used for examining freshness of shrimp. In this experiment, shrimp were stored in sealed bottles that have been labeled using the indicator and stored at 13 °C, 25 °C, and 40 °C for a certain range of time. Color changes of the indicator labels were observed using digital photography after shrimp storage for 0 h, 2 h, 17 h and 24 h. The color changes that occur were quantified and analyzed using the ImageJ program. The color of the indicator label when detecting the fresh shrimp was pink and after the shrimp spoilage began, the color of the label changed to purple and then became yellow when the shrimp is badly spoilage. The color change rates of label indicator increases as the shrimp storage temperature increased. These results indicate that this label indicator can be used as an indicator of the freshness of shrimps and it is not toxic and safe for food.
Pölz, Stefan; Laubersheimer, Sven; Eberhardt, Jakob S; Harrendorf, Marco A; Keck, Thomas; Benzler, Andreas; Breustedt, Bastian
2013-08-21
The basic idea of Voxel2MCNP is to provide a framework supporting users in modeling radiation transport scenarios using voxel phantoms and other geometric models, generating corresponding input for the Monte Carlo code MCNPX, and evaluating simulation output. Applications at Karlsruhe Institute of Technology are primarily whole and partial body counter calibration and calculation of dose conversion coefficients. A new generic data model describing data related to radiation transport, including phantom and detector geometries and their properties, sources, tallies and materials, has been developed. It is modular and generally independent of the targeted Monte Carlo code. The data model has been implemented as an XML-based file format to facilitate data exchange, and integrated with Voxel2MCNP to provide a common interface for modeling, visualization, and evaluation of data. Also, extensions to allow compatibility with several file formats, such as ENSDF for nuclear structure properties and radioactive decay data, SimpleGeo for solid geometry modeling, ImageJ for voxel lattices, and MCNPX's MCTAL for simulation results have been added. The framework is presented and discussed in this paper and example workflows for body counter calibration and calculation of dose conversion coefficients is given to illustrate its application.
MODIFIED PATH METHODOLOGY FOR OBTAINING INTERVAL-SCALED POSTURAL ASSESSMENTS OF FARMWORKERS.
Garrison, Emma B; Dropkin, Jonathan; Russell, Rebecca; Jenkins, Paul
2018-01-29
Agricultural workers perform tasks that frequently require awkward and extreme postures that are associated with musculoskeletal disorders (MSDs). The PATH (Posture, Activity, Tools, Handling) system currently provides a sound methodology for quantifying workers' exposure to these awkward postures on an ordinal scale of measurement, which places restrictions on the choice of analytic methods. This study reports a modification of the PATH methodology that instead captures these postures as degrees of flexion, an interval-scaled measurement. Rather than making live observations in the field, as in PATH, the postural assessments were performed on photographs using ImageJ photo analysis software. Capturing the postures in photographs permitted more careful measurement of the degrees of flexion. The current PATH methodology requires that the observer in the field be trained in the use of PATH, whereas the single photographer used in this modification requires only sufficient training to maintain the proper camera angle. Ultimately, these interval-scale measurements could be combined with other quantitative measures, such as those produced by electromyograms (EMGs), to provide more sophisticated estimates of future risk for MSDs. Further, these data can provide a baseline from which the effects of interventions designed to reduce hazardous postures can be calculated with greater precision. Copyright© by the American Society of Agricultural Engineers.
Pantic, Igor; Dacic, Sanja; Brkic, Predrag; Lavrnja, Irena; Pantic, Senka; Jovanovic, Tomislav; Pekovic, Sanja
2014-10-01
This aim of this study was to assess the discriminatory value of fractal and grey level co-occurrence matrix (GLCM) analysis methods in standard microscopy analysis of two histologically similar brain white mass regions that have different nerve fiber orientation. A total of 160 digital micrographs of thionine-stained rat brain white mass were acquired using a Pro-MicroScan DEM-200 instrument. Eighty micrographs from the anterior corpus callosum and eighty from the anterior cingulum areas of the brain were analyzed. The micrographs were evaluated using the National Institutes of Health ImageJ software and its plugins. For each micrograph, seven parameters were calculated: angular second moment, inverse difference moment, GLCM contrast, GLCM correlation, GLCM variance, fractal dimension, and lacunarity. Using the Receiver operating characteristic analysis, the highest discriminatory value was determined for inverse difference moment (IDM) (area under the receiver operating characteristic (ROC) curve equaled 0.925, and for the criterion IDM≤0.610 the sensitivity and specificity were 82.5 and 87.5%, respectively). Most of the other parameters also showed good sensitivity and specificity. The results indicate that GLCM and fractal analysis methods, when applied together in brain histology analysis, are highly capable of discriminating white mass structures that have different axonal orientation.
The effect of CO2 laser treatment on skin tissue.
Baleg, Sana Mohammed Anayb; Bidin, Noriah; Suan, Lau Pik; Ahmad, Muhammad Fakarruddin Sidi; Krishnan, Ganesan; Johari, Abd Rahman; Hamid, Asma
2015-09-01
The aim of this study was to evaluate the effects of multiple pulses on the depth of injury caused by CO2 laser in an in vivo rat model. A 10 600-nm CO2 laser was applied to rat skin, with one side of the rat dorsal skin being exposed, leaving the other side as a control. All of the various laser pulses tested led to gradual loss of epidermal thickness as well as a dramatic increase in thermal damage depth. Collagen coagulation was most effective with ten pulses of CO2 laser, while the strength of irradiated skin tissue increased as the influence of the laser increased. Fundamental laser-skin interaction effects were studied using a CO2 laser. The photodamaged areas obtained from laser interaction were recorded via couple charge device video camera and analyzed via ImageJ software. Photodamage induced by CO2 laser is due to photothermal effects, which involve burning and vaporizing mechanisms to ablate the epidermis layer. The burning area literally expands and penetrates deep into the dermis layer, subsequently causing collagen coagulation. This fundamental study shows in detail the effect of CO2 laser interaction with skin. The CO2 attributed severe burning, producing deep coagulation, and induced strength to treated skin. © 2015 Wiley Periodicals, Inc.
Patel, Aarti; Purohit, Ravi; Lee, Helena; Sheth, Viral; Maconachie, Gail; Papageorgiou, Eleni; McLean, Rebecca J; Gottlob, Irene; Proudlock, Frank A
2016-10-01
To determine feasibility of optic nerve head (ONH) imaging and to characterize ONH development in full-term infants without sedation using handheld spectral-domain optical coherence tomography (SD OCT). Prospective cross-sectional study. Three hundred fifty-two children aged between 1 day and 13 years. All participants were imaged using handheld SD OCT without sedation during a single scan session. The percentage of successful scans was calculated. Interexaminer reproducibility and differences between right and left eyes were assessed using intraclass correlation coefficients (ICCs). Images were analyzed using ImageJ software. The developmental trajectories over time for ONH parameters were calculated using fractional polynomial modelling. Disc and cup diameter (expressed as distance in micrometers and visual angle in degrees), cup depth, Bruch's membrane opening-minimum rim width (BMO-MRW), retinal thickness, and retinal nerve fiber layer (RNFL; 1700 μm and 6° from the disc center). On average, 70% of participants were imaged successfully. Interexaminer reliability was excellent (ICC, >0.89) for diametric and retinal thickness parameters. Right and left eyes were similar for diametric measurements (ICC, >0.79), but more variable for nasal BMO-MRW, RNFL, and retinal thickness. The mean disc and cup diameter increase by 30% and 40%, respectively, between birth and 13 years of age when expressed as a distance measure, but remained constant (at 5°-5.5° and 2°, respectively) when expressed as a visual angle with reference to the eye nodal point. The peripapillary temporal RNFL demonstrated a marked initial decrease of nearly 35% between birth and approximately 18 months of age. This was followed by a slow increase up to 12 years of age when measured at 1700 μm from the disc center, although there was little change when measured at 6° from the disc center. We demonstrated feasibility of handheld SD OCT imaging of the ONH in full-term infants and children without anaesthesia or sedation. This is the first in vivo handheld SD OCT study to describe the development of ONH parameters during the critical early years of visual maturation. Our results provide a normative database for use in routine practice and further studies of ONH pathologic features. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Celik, Cigdem; Cehreli, Sevi Burcak; Arhun, Neslihan
2015-01-01
Objective: The aim was to evaluate the effect of different adhesive systems and surface treatments on the integrity of resin-resin and resin-tooth interfaces after partial removal of preexisting resin composites using quantitative image analysis for microleakage testing protocol. Materials and Methods: A total of 80 human molar teeth were restored with either of the resin composites (Filtek Z250/GrandioSO) occlusally. The teeth were thermocycled (1000×). Mesial and distal 1/3 parts of the restorations were removed out leaving only middle part. One side of the cavity was finished with course diamond bur and the other was air-abraded with 50 μm Al2O3. They were randomly divided into four groups (n = 10) to receive: Group 1: Adper Single Bond 2; Group 2: All Bond 3; Group 3: ClearfilSE; Group 4: BeautiBond, before being repaired with the same resin composite (Filtek Z250). The specimens were re-thermocycled (1000×), sealed with nail varnish, stained with 0.5% basic fuchsin, sectioned mesiodistally and photographed digitally. The extent of dye penetration was measured by image analysis software (ImageJ) for both bur-finished and air-abraded surfaces at resin-tooth and resin-resin interfaces. The data were analyzed statistically. Results: BeautiBond exhibited the most microleakage at every site. Irrespective of adhesive and initial composite type, air-abrasion showed less microleakage except for BeautiBond. The type of initial repaired restorative material did not affect the microleakage. BeautiBond adhesive may not be preferred in resin composite repair in terms of microleakage prevention. Conclusions: Surface treatment with air-abrasion produced the lowest microleakage scores, independent of the adhesive systems and the pre-existing resin composite type. Pre-existing composite type does not affect the microleakage issue. All-in-one adhesive resin (BeautiBond) may not be preferred in resin composite repair in terms of microleakage prevention. PMID:25713491
Macropore system characteristics controls on non-reactive solute transport at different flow rates
NASA Astrophysics Data System (ADS)
Larsbo, Mats; Koestel, John
2014-05-01
Preferential flow and transport in macroporous soils are important pathways for the leaching of agrochemicals through soils. Preferential solute transport in soil is to a large extent determined by the macropore system characteristics and the water flow conditions. The importance of different characteristics of the macropore system is likely to vary with the flow conditions. The objective of this study was to determine which properties of the macropore system that control the shape of non-reactive tracer solute breakthrough curves at different steady-state flow rates. We sampled five undisturbed columns (20 cm high, 20 cm diameter) from the soil surface of four soils with clay contents between 21 and 50 %. Solute transport experiments were carried out under unsaturated conditions at 2, 4, 6, 8 and 12 mm h-1 flow rates. For each flow rate a pulse of potassium bromide solution was applied at the soil surface and the electrical conductivity was measured with high temporal resolution in the column effluent. We used the 5 % arrival time and the holdback factor to estimate the degree of preferential transport from the resulting breakthrough curves. Unsaturated hydraulic conductivities were measured at the soil surface of the columns using a tension disc infiltrometer. The macropore system was imaged by industrial X-ray computed tomography at a resolution of 125 μm in all directions. Measures of the macropore system characteristics including measures of pore continuity were calculated from these images using the ImageJ software. Results show that the degree of preferential transport is generally increasing with flow rate when larger pores become active in the transport. The degree of preferential flow was correlated to measures of macropore topology. This study show that conclusions drawn from experiments carried out at one flow rate should generally not be extrapolated to other flow rates.
Dastiridou, Anna; Marion, Kenneth; Niemeyer, Moritz; Francis, Brian; Sadda, Srinivas; Chopra, Vikas
2018-04-11
To investigate the effects of ambient light level variation on spectral domain anterior segment optical coherence tomography (SD-ΟCT)-derived anterior chamber angle metrics in Caucasians versus Asians. Caucasian (n = 24) and Asian participants of Chinese ancestry (n = 24) with open angles on gonioscopy had one eye imaged twice at five strictly controlled, ambient light levels. Ethnicity was self-reported. Light levels were strictly controlled using a light meter at 1.0, 0.75, 0.5, 0.25, and 0 foot candle illumination levels. SD-OCT 5-line raster scans at the inferior 270° irido-corneal angle were measured by two trained, masked graders from the Doheny Image Reading Center using customized Image-J software. Schwalbe's line-angle opening distance (SL-AOD) and SL-trabecular iris space area (SL-TISA) in different light meter readings (LMRs) between the two groups were compared. Baseline light SL-AOD and SL-TISA measured 0.464 ± 0.115mm/0.351 ± 0.110mm 2 and 0.344 ± 0.118mm/0.257 ± 0.092mm 2 , respectively, in the Caucasian and the Asian group. SL-AOD and SL-TISA in each LMR were significantly larger in the Caucasian group compared to the Asian group (p < 0.05). Despite this difference in angle size between the groups, there were no statistically significant differences in the degree of change in angle parameters from light to dark (% changes in SL-AOD or SL-TISA between the two groups were statistically similar with all p-values >0.3). SL-based angle dimensions using SD-OCT are sensitive to changes in ambient illumination in participants with Caucasian and Asian ancestry. Although Caucasian eyes had larger baseline angle opening under bright light conditions, the light-to-dark change in angle dimensions was similar in the two groups.
Lee, Ji Young; Chung, Hyewon; Kim, Hyung Chan
2016-02-01
To describe the changes of fundus autofluorescence (FAF) in patients with age-related macular degeneration before and after intravitreal injection of anti-vascular endothelial growth factor according to the type of choroidal neovascularization (CNV) and to evaluate the correlation of FAF with spectral domain optical coherence tomography (SD-OCT) parameters and vision. This was a retrospective study. Twenty-one treatment-naïve patients with neovascular age-related macular degeneration were included. Study eyes were divided into two groups according to the type of CNV. Fourteen eyes were type 1 CNV and seven eyes were type 2 CNV. All eyes underwent a complete ophthalmologic examination, including an assessment of best-corrected visual acuity, SD-OCT, fluorescein angiography, and FAF imaging, before and 3 months after intravitreal anti-vascular endothelial growth factor injection. Gray scales of FAF image for CNV areas, delineated as in fluorescein angiography, were analyzed using the ImageJ program, which were adjusted by comparison with normal background areas. Correlation of changes in FAF with changes in SD-OCT parameters, including CNV thickness, photoreceptor inner and outer segment junction disruption length, external limiting membrane disruption length, central macular thickness, subretinal fluid, and intraretinal fluid were analyzed. Eyes with both type 1 and type 2 CNV showed reduced FAF before treatment. The mean gray scales (%) of type 1 and type 2 CNV were 52.20% and 42.55%, respectively. The background values were 106.72 and 96.86. After treatment, the mean gray scales (%) of type 1 CNV and type 2 CNV were changed to 57.61% (p = 0.005) and 57.93% (p = 0.008), respectively. After treatment, CNV thickness, central macular thickness, and inner and outer segment junction disruption length were decreased while FAF increased. FAF was noted to be reduced in eyes with newly diagnosed wet age-related macular degeneration, but increased after anti-vascular endothelial growth factor therapy regardless of CNV lesion type.
Measurements from preterm infants to guide face mask size.
O'Shea, Joyce E; Thio, Marta; Owen, Louise S; Wong, Connie; Dawson, Jennifer A; Davis, Peter G
2016-07-01
International guidelines recommend that an appropriately sized face mask for providing positive pressure ventilation should cover the mouth and nose but not the eyes and should not overlap the chin. This study aimed to measure the dimensions of preterm infants' faces and compare these with the size of the most commonly available face masks (external diameter 50 mm) and the smallest masks available (external diameters 35 and 42 mm). Infants 24-33 weeks' postmenstrual age (PMA) were photographed in a standardised manner. Images were analysed using ImageJ software (National Institute of Health, USA) to calculate the distance from the nasofrontal groove to the mental protuberance. This facial measurement corresponds to the external diameter of an optimally fitting mask. A cohort of 107 infants between 24 and 33 weeks' gestational age, including at least 10 infants per week of gestation, was photographed within 72 h after birth and weekly until 33 weeks' PMA. 347 photographs were analysed. Infants of 24, 26, 28, 30 and 32 weeks' PMA had mean (SD) facial measurements of 32 (2), 36 (3), 38 (4), 41 (2) and 43 (4) mm, respectively. There were no significant differences when examined by gender or when small for gestational age infants were excluded. The smallest size of some brands of mask is too large for many preterm infants. Masks of 35 mm diameter are suitable for infants <29 weeks' PMA or 1000 g. Masks of 42 mm diameter are suitable for infants 27-33 weeks' PMA or 750-2500 g. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Wu, Yuan; Li, Haili; Tang, Yun; Yan, Xiaoming
2017-03-01
To compare, in vivo, differences in meibomian gland morphology between children and adolescents. Sixty-nine patients were included in this study and divided into two groups: children (n = 31; age range: 3 to 11 years) and adolescents (n = 39; age range: 12 to 18 years). Images of meibomian glands were obtained by infrared meibography and analyzed using ImageJ software (developed by the National Institutes of Health; available at http://rsb.info.nih.gov/ij/download.html). Meibomian gland loss, the number of meibomian gland ducts, the relative width of the meibomian gland ducts, and the percent area of the meibomian gland acini were compared between the two groups. Meibomian gland loss was found in both groups, but the meiboscore was not significantly different between the two groups (0.35 ± 0.6 vs 0.41 ± 0.8, t = -0.314, P > .05). The number of meibomian gland ducts (25.85 ± 3.25 vs 23.23 ± 3.06, t = -3.437, P < .05), relative width of the meibomian gland ducts (69.62% ± 5% vs 66.1% ± 7%, t = -2.454, P < .05), and percent area of the meibomian gland acini (57.7% ± 4% vs 55.5% ± 4%, t = 2.571, P < .05) in the upper eyelid were significantly greater in adolescents than in children. However, no significant differences were found in the lower eyelid between the two groups. Meibography is useful for the assessment of ocular surface conditions in children and adolescents. Meibomian gland loss occurs in both children and adolescents. The meibomian glands of the upper eyelid exhibit more morphological changes in adolescents than in children. [J Pediatr Ophthalmol Strabismus. 2017;54(2):78-83.]. Copyright 2017, SLACK Incorporated.
A Killer Asteroids Research Project for Undergraduate Non-Majors
NASA Astrophysics Data System (ADS)
Puckett, Andrew W.; Rector, T. A.
2009-01-01
We present a progress report on the development and testing of our Killer Asteroids Research Project, which enables the assessment of asteroid impact risk in the undergraduate classroom. This is part of an NSF CCLI grant to develop Research Based Science Education (RBSE) curricula for non-majors. Our curricula include six projects covering astrometric, photometric, and spectroscopic techniques, which are being tested at multiple schools of varying sizes around the country. We report on the second semester of testing this project with undergraduates at the University of Alaska Anchorage. Students use our Polaris Plugin for ImageJ to perform both astrometry and aperture photometry on research-grade astronomical images. The output is fed into Find_Orb, which uses a Monte Carlo method to compute orbital elements for thousands of possible orbits. The resulting orbit database is then fed into a planetarium program, which allows students to visualize the uncertainty region and to observe how that region changes with time and/or additional data. For potentially hazardous asteroids, impact risk is assessed by counting the number of "clone” orbits that strike a planet's surface. Alternatively, the output from our plugin can be used directly to measure the lightcurves of minor planets, leading to an improved understanding of their shapes. This plugin is the first FITS reader to produce correct time-stamps for minor planet observations found in the SDSS, which observes in drift-scan mode. Recent progress is promising. We are in dialogue with software engineers behind both Starry Night and Guide, helping to improve these planetarium programs as research tools. We are also constantly improving the Polaris Plugin, most recently to make it compatible with the astrometry format used by the websites NeoDys and AstDys.
Muscle size, quality, and body composition: characteristics of division I cross-country runners.
Roelofs, Erica J; Smith-Ryan, Abbie E; Melvin, Malia N; Wingfield, Hailee L; Trexler, Eric T; Walker, Nina
2015-02-01
The primary purpose of this study was to identify the relationship between muscle cross-sectional area (mCSA), echo intensity (EI), and body composition of Division I cross-country runners. The secondary purpose was to examine differences in these variables in athletes stratified based on stress-fracture (SFx) history. Thirty-six athletes were stratified based on sex and SFx history. A panoramic scan vastus lateralis was performed using a GE Logiq-e B-mode ultrasound. Echo intensity and mCSA were determined from the scan using a grayscale imaging software (ImageJ). Body composition measures were determined using dual-energy x-ray absorptiometry. For females, mCSA was significantly correlated with left leg lean mass (LM; R = 0.54) and EI (R = -0.57). Lean mass was significantly correlated with bone mineral density (BMD; R = 0.58) and bone mineral content (BMC; R = 0.56), whereas BMC was also correlated with leg LM (R = 0.72). For males, mCSA was significantly correlated with leg LM (R = 0.66), BMD (R = 0.50), and BMC (R = 0.54). Leg LM was significantly correlated with BMD (R = 0.53) and BMC (R = 0.77). Personal best times for males were significantly correlated with fat mass (R = 0.489) and %fat (R = 0.556) for the 10- and 5-km races, respectively. Female and male athletes with a history of SFx were not significantly different across any variables when compared with athletes with no history. These correlations suggest that more muscle mass may associate with higher BMD and BMC for stronger bone structure. Modifications in training strategies to include heavy resistance training and plyometrics may be advantageous for preventing risk factors associated with SFx reoccurrence.
Radbruch, Alexander; Eidel, Oliver; Wiestler, Benedikt; Paech, Daniel; Burth, Sina; Kickingereder, Philipp; Nowosielski, Martha; Bäumer, Philipp; Wick, Wolfgang; Schlemmer, Heinz-Peter; Bendszus, Martin; Ladd, Mark; Nagel, Armin Michael; Heiland, Sabine
2014-01-01
Purpose To analyze if tumor vessels can be visualized, segmented and quantified in glioblastoma patients with time of flight (ToF) angiography at 7 Tesla and multiscale vessel enhancement filtering. Materials and Methods Twelve patients with newly diagnosed glioblastoma were examined with ToF angiography (TR = 15 ms, TE = 4.8 ms, flip angle = 15°, FOV = 160×210 mm2, voxel size: 0.31×0.31×0.40 mm3) on a whole-body 7 T MR system. A volume of interest (VOI) was placed within the border of the contrast enhancing part on T1-weighted images of the glioblastoma and a reference VOI was placed in the non-affected contralateral white matter. Automated segmentation and quantification of vessels within the two VOIs was achieved using multiscale vessel enhancement filtering in ImageJ. Results Tumor vessels were clearly visible in all patients. When comparing tumor and the reference VOI, total vessel surface (45.3±13.9 mm2 vs. 29.0±21.0 mm2 (p<0.035)) and number of branches (3.5±1.8 vs. 1.0±0.6 (p<0.001) per cubic centimeter were significantly higher, while mean vessel branch length was significantly lower (3.8±1.5 mm vs 7.2±2.8 mm (p<0.001)) in the tumor. Discussion ToF angiography at 7-Tesla MRI enables characterization and quantification of the internal vascular morphology of glioblastoma and may be used for the evaluation of therapy response within future studies. PMID:25415327
Tang, Ya Hui; Thompson, R Will; Nathan, Cherie-Ann; Alexander, Jonathan Steven; Lian, Timothy
2018-06-01
The lack of real-time assessment of vascular perfusion changes remains a major weakness in assessing the efficacy of bone marrow stromal cells (BMSC) therapeutic ischemia reperfusion (I/R) injury. This study provides for the first time the real-time in vivo perfusion monitoring in I/R mice with BMSC therapy. Animal model. Surgically created cutaneous flaps perfused by the inferior epigastric vessels were subjected to 3.5 hours of ischemia/reperfusion. Wound healing and vascular perfusion were assessed by Image-J and laser speckle contrast analysis (LSCA) in three groups (sham, I/R, and I/R + BMSC). BMSC tracking was quantified in an additional two groups (with/without I/R) using intravital fluorescent microscopy. The histopathology of skin flaps was examined by hematoxylin and eosin stain. Infiltrated macrophages were analyzed by confocal immunofluorescent microscopy. Postischemic tissues treated with BMSC demonstrated significantly greater survival than I/R control. On days 3 to 7 postreperfusion, both proximal and distal areas in BMSC-treated flaps demonstrated greater levels of perfusion than untreated I/R flaps (P < 0.05). Intravital fluorescent microscopy revealed that numbers of labeled BMSC were significantly increased in the distal area compared to the proximal area in both with and without ischemic mice. Histological examination showed lower necrosis and infiltrated inflammatory cells in I/R + BMSC-treated mice versus I/R controls. BMSC accumulated in I/R flaps and exerted beneficial effects including: 1) improving vascular perfusion and 2) attenuating inflammatory cell infiltration. LSCA facilitates monitoring of the real-time restitution of perfusion during flap wound healing in experimental animals and could also similarly applied in clinical investigations. NA. Laryngoscope, 128:E198-E205, 2018. © 2018 The American Laryngological, Rhinological and Otological Society, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brezovich, I; Wu, X; Popple, R
Purpose: To test spatial and dosimetric accuracy of small cranial target irradiation based on 1.5 T MRI scans using static arcs with MLC-defined fields Methods: A plastic (PMMA) phantom simulating a small brain lesion was mounted on a GammaKnife headframe equipped with MRI localizer. The lesion was a 3 mm long, 3.175 mm diameter cylindrical cavity filled with MRI contrast. Radiochromic film passing through the cavity was marked with pin pricks at the cavity center. The cavity was contoured on an MRI image and fused with CT to simulate treatment of a lesion not visible on CT. The transfer ofmore » the target to CT involved registering the MRI contrast cannels of the localizer that were visible on both modalities. Treatments were planned to deliver 800 cGy to the cavity center using multiple static arcs with 5.0×2.4 mm MLC-defined fields. The phantom was aligned on a STx accelerator by registering the conebeam CT with the planning CT. Films from coronal and sagittal planes were scanned and evaluated using ImageJ software Results: Geographic errors in treatment based on 1.5 T scans agreed within 0.33, −0.27 and 1.21 mm in the vertical, lateral and longitudinal dimensions, respectively. The doses delivered to the cavity center were 7.2% higher than planned. The dose distributions were similar to those of a GammaKnife. Conclusion: Radiation can be delivered with an accelerator at mm accuracy to small cranial targets based on 1.5 MRI scans fused to CTs using a standard GammaKnife headframe and MRI localizer. MLC-defined static arcs produce isodose lines very similar to the GammaKnife.« less
Pramojanee, Sakarat; Thaiupathump, Trasapong
2013-01-01
Purpose This study was performed to determine the relationship between the stage of tooth eruption (both vertical and mesio-angular) and chronological age. Materials and Methods Indirect digital panoramic radiographs were used to measure the distances from the dentinoenamel junction (DEJ) of the second molars to the occlusal plane of the second molar teeth and of the adjacent third molars in 264 Thai males and 437 Thai females using ImageJ software. The ratio of those distances was calculated by patient age, and the correlation coefficient of the ratio of the third molar length to the second molar length was calculated. Results The correlation between the height of the vertically erupted upper third molar teeth and age was at the intermediate level. The age range of ≥15 to <16 years was noted to be the range in which the correlation between the chronological age determined from the eruptional height and actual chronological age was statistically significant. The mean age of the female subjects, in which the position of the right upper third molar teeth was at or above the DEJ of the adjacent second molar but below one half of its coronal height was 19.9±2.6 years. That for the left side was 20.2±2.7 years. The mean ages of the male subjects were 20.1±3.3 years and 19.8±2.7 years for the right and left sides, respectively. Conclusion It might be possible to predict chronological age from the eruption height of the wisdom teeth. PMID:24380069
A new approach to geometrical measurements in an animal model of vocal fold scar.
Jabbour, Noel; Krishna, Priya D; Osborne, James; Rosen, Clark A
2009-01-01
A standard method for quantifying the geometric properties of vocal folds has not been widely adopted. An ideal method of geometrical measurement should effectively quantify the dimensions of the medial vibratory portion of the vocal fold, should be easily performed, should yield consistent results, and should be readily available at little to no cost. We have developed a new approach for geometrical measurements to meet these goals. The objective of this study is to describe this new approach and to assess its effectiveness in a canine model of vocal fold scar. One hundred thirty-five mid-membranous coronal sections of vocal folds from 10 canines (five with unilateral surgical scarring) were examined by light microscopy; digital images were captured. ImageJ was used to measure a variety of described parameters. Comparison between scarred vocal folds and control vocal folds was made. At least 20% of the slides for each vocal fold were randomly selected (n=42) for repeat measurements of interrater and intrarater reliability. A statistically significant difference between scarred and control vocal folds was obtained for horizontal distance (P<0.001), vertical distance (P=0.005), area (P<0.001), mean optical density (OD) (P<0.001), and OD at defined points along the length of the vocal fold (P< or =0.009). Reliability calculations for intrarater and interrater measurements ranged from r=0.845 to r=0.994 and from r=0.734 to r=0.976, respectively. The proposed approach for geometrical measurements meets the intended objectives in a canine model of vocal fold scar. Future work is needed to apply this approach to other model systems.
Hiroshima, Yukihiko; Shuto, Kiyohiko; Yamazaki, Kazuto; Kawaguchi, Daisuke; Yamada, Masatoshi; Kikuchi, Yutaro; Kasahara, Kohei; Murakami, Takashi; Hirano, Atsushi; Mori, Mikito; Kosugi, Chihiro; Matsuo, Kenichi; Ishida, Yasuo; Koda, Keiji; Tanaka, Kuniya
2016-12-01
Chemotherapy-induced liver injury after potent chemotherapy is a considerable problem in patients undergoing liver resection. The aim of this study was to assess the relationship between the fractal dimension (FD) of Tc-99m diethylenetriaminepentaacetic acid (DTPA) galactosyl human serum albumin (GSA) and pathologic change of liver parenchyma in liver cancer patients who have undergone chemotherapy. We examined 34 patients (10 female and 24 male; mean age, 68.5 years) who underwent hepatectomy. Hepatic injury was defined as steatosis more than 30 %, grade 2-3 sinusoidal dilation, and/or steatohepatitis Kleiner score ≥4. Fractal analysis was applied to all images of Tc-99m DTPA GSA using a plug-in tool on ImageJ software (NIH, Bethesda, MD). A differential box-counting method was applied, and FD was calculated as a heterogeneity parameter. Correlations between FD and clinicopathological variables were examined. FD values of patients with steatosis and steatohepatitis were significantly higher than those without (P > .001 and P > .001, respectively). There was no difference between the FD values of patients with and without sinusoidal dilatation (P = .357). Multivariate logistic regression showed FD as the only significant predictor for steatosis (P = .005; OR 36.5; 95 % CI 3.0-446.3) and steatohepatitis (P = .012; OR, 29.1; 95 % CI 2.1-400.1). FD of Tc-99m DTPA GSA was the significant predictor for fatty liver disease in patients who underwent chemotherapy. This new modality is able to differentiate steatohepatitis from steatosis; therefore, it may be useful for predicting chemotherapy-induced pathologic liver injury.
Nav1.7 expression is increased in painful human dental pulp.
Luo, Songjiang; Perry, Griffin M; Levinson, S Rock; Henry, Michael A
2008-04-21
Animal studies and a few human studies have shown a change in sodium channel (NaCh) expression after inflammatory lesions, and this change is implicated in the generation of pain states. We are using the extracted human tooth as a model system to study peripheral pain mechanisms and here examine the expression of the Nav1.7 NaCh isoform in normal and painful samples. Pulpal sections were labeled with antibodies against: 1) Nav1.7, N52 and PGP9.5, and 2) Nav1.7, caspr (a paranodal protein used to identify nodes of Ranvier), and myelin basic protein (MBP), and a z-series of optically-sectioned images were obtained with the confocal microscope. Nav1.7-immunofluorescence was quantified in N52/PGP9.5-identified nerve fibers with NIH ImageJ software, while Nav1.7 expression in myelinated fibers at caspr-identified nodal sites was evaluated and further characterized as either typical or atypical as based on caspr-relationships. Results show a significant increase in nerve area with Nav1.7 expression within coronal and radicular fiber bundles and increased expression at typical and atypical caspr-identified nodal sites in painful samples. Painful samples also showed an augmentation of Nav1.7 within localized areas that lacked MBP, including those associated with atypical caspr-identified sites, thus identifying NaCh remodeling within demyelinating axons as the basis for a possible pulpal pain mechanism. This study identifies the increased axonal expression and augmentation of Nav1.7 at intact and remodeling/demyelinating nodes within the painful human dental pulp where these changes may contribute to constant, increased evoked and spontaneous pain responses that characterize the pain associated with toothache.
Examination of Multiple Lithologies Within the Primitive Ordinary Chondrite NWA 5717
NASA Technical Reports Server (NTRS)
Cato, M. J.; Simon, J. I.; Ross, D. K.; Morris, R. V.
2017-01-01
Northwest Africa 5717 is a primitive (subtype 3.05) ungrouped ordinary chondrite which contains two apparently distinct lithologies. In large cut meteorite slabs, the darker of these, lithology A, looks to host the second, much lighter in color, lithology B (upper left, Fig. 1). The nature of the boundary between the two is uncertain, ranging from abrupt to gradational and not always following particle boundaries. The distinction between the lithologies, beyond the obvious color differences, has been supported by a discrepancy in oxygen isotopes and an incongruity in the magnesium contents of chondrule olivine. Here, quantitative textural analysis and mineralogical methods have been used to investigate the two apparent lithologies within NWA 5717. Olivine grains contained in a thin section from NWA 7402, thought to be paired to 5717, were also measured to re-examine the distinct compositional range among the light and dark areas. Procedure: Particles from a high-resolution mosaic image of a roughly 13x15cm slice of NWA 5717 were traced in Adobe Photoshop. Due to the large size of the sample, visually representative regions of each lithology were chosen to be analyzed. The resulting layers of digitized particles were imported into ImageJ, which was used to measure their area, along with the axes, the angle from horizontal, and the centroid coordinates of ellipses fitted to each particle following the approach. Resulting 2D pixel areas were converted to spherical diameters employing the unfolding algorithm, which outputs a 3D particle size distribution based on digitized 2D size frequency data. Spatstat was used to create kernel density plots of the centroid coordinates for each region. X-ray compositional maps, microprobe analyses, and Mossbauer spectroscopy was conducted on a thin section of NWA 7402, tentatively paired to NWA 5717.
A robust sebum, oil, and particulate pollution model for assessing cleansing efficacy of human skin.
Peterson, G; Rapaka, S; Koski, N; Kearney, M; Ortblad, K; Tadlock, L
2017-06-01
With increasing concerns over the rise of atmospheric particulate pollution globally and its impact on systemic health and skin ageing, we have developed a pollution model to mimic particulate matter trapped in sebum and oils creating a robust (difficult to remove) surrogate for dirty, polluted skin. To evaluate the cleansing efficacy/protective effect of a sonic brush vs. manual cleansing against particulate pollution (trapped in grease/oil typical of human sebum). The pollution model (Sebollution; sebum pollution model; SPM) consists of atmospheric particulate matter/pollution combined with grease/oils typical of human sebum. Twenty subjects between the ages of 18-65 were enrolled in a single-centre, cleansing study comparisons between the sonic cleansing brush (normal speed) compared to manual cleansing. Equal amount of SPM was applied to the centre of each cheek (left and right). Method of cleansing (sonic vs. manual) was randomized to the side of the face (left or right) for each subject. Each side was cleansed for five-seconds using the sonic cleansing device with sensitive brush head or manually, using equal amounts of water and a gel cleanser. Photographs (VISIA-CR, Canfield Imaging, NJ, USA) were taken at baseline (before application of the SPM), after application of SPM (pre-cleansing), and following cleansing. Image analysis (ImageJ, NIH, Bethesda, MD, USA) was used to quantify colour intensity (amount of particulate pollutants on the skin) using a scale of 0 to 255 (0 = all black pixels; 255 = all white pixels). Differences between the baseline and post-cleansing values (pixels) are reported as the amount of SPM remaining following each method of cleansing. Using a robust cleansing protocol to assess removal of pollutants (SPM; atmospheric particulate matter trapped in grease/oil), the sonic brush removed significantly more SPM than manual cleansing (P < 0.001). While extreme in colour, this pollution method easily allows assessment of efficacy through image analysis. © 2016 The Authors. International Journal of Cosmetic Science published by John Wiley & Sons Ltd on behalf of Society of Cosmetic Scientists and the Société Française de Cosmétologie.
Abdul Aziz,, Siti Aishah; Mohd Saparudin, Abdul Khaliq; Harun, Ahmad Zaky
2013-01-01
Background: Different target-filter combinations in computed radiography have different impacts on the dose and image quality in digital radiography. This study aims to evaluate the mean glandular dose (MGD) and modulation transfer function (MTF) of various target-filter combinations by investigating the signal intensities of X-ray beams. Methods: General Electric (GE) Senographe DMR Plus mammography unit was used for MGD and MTF evaluation. The measured MGD was compared with the dose reference level (DRL), whereas the MTF was evaluated using ImageJ 1.46o software. A modified Mammography Accreditation Phantom RMI 156 was exposed using different target-filter combinations of molybdenum-molybdenum (Mo-Mo), molybdenum-rhodium (Mo-Rh) and rhodium-rhodium (Rh-Rh) at two different tube voltages, 26 kV and 32 kV with 50 mAs. Results: In the MGD evaluations, all target-filters gave an MGD value of < 1.5 mGy. The one-way ANOVA test showed a highly significant interaction between the MGD and the kilovoltage and target-filter material used (26 kV: F (2,12) = 49,234, P = 0.001;32 kV: F (2,12) = 89,972, P = 0.001). A Tukey post-hoc test revealed that the MGD for 26 kV and 32 kV was highly affected by the target-filter combinations. The test of homogeneity of variances indicates that the MGD varies significantly for 26 kV and 32 kV images (0.045 and 0.030 (P < 0.05), respectively). However, the one-way ANOVA for the MTF shows that no significant difference exists between the target-filter combinations used with 26 kV and 32 kV images either in parallel or perpendicular to the chest wall side F (2,189) = 0.26, P > 0.05). Conclusion: Higher tube voltage and atomic number target-filter yield higher MGD values. However, the MTF is independent of the X-ray energy and the type of target-filter combinations used. PMID:23966821
NASA Astrophysics Data System (ADS)
Tominaga, M.
2010-12-01
Understanding the detailed architecture of the upper ocean crust is one of the key components to advance our knowledge on numerous events occurring in the oceanic lithosphere from spreading ridges to subduction zones. Studies on crustal characterization are limited to either the crustal or hand-specimen scales so far, and little has been done at centimeter - meter scale, which potentially ties those two end-member prospects. The lack of this scale is due mainly to the difficulties in direct sampling and the limited resolution of geophysical experiments; as a consequence, critical questions remain unanswered, e.g., what does the cross-section of actual ocean crust look like and what does it tell us?; where exactly in the lithosphere does fluid exist and promote the deep hydration and biosphere?; to what extent do we average out the heterogeneity in the crustal properties depending on the scale? Ocean Drilling Program (ODP) Hole 1256D is located at the 15 Ma super-fast spreading Cocos Plate and the first drilled hole that successfully penetrate through the intact upper ocean crust. Coring in the Hole 1256D basement is suffered from the low core recovery rates (~ 32 %) and the origins of recovered cores are mostly biased toward formations with minimal fractures. Wire-line logging in this hole becomes, thus, extremely useful for both the physical and chemical characterization of the crust. In particular, Formation MicroScanner (FMS) data acquired from multiple paths during three drilling expeditions have unprecedented lateral coverage of the borehole wall. The FMS images are the first realization of the cross-section of in situ architecture of the intact upper ocean crust with a centimeter-meter scale resolution. A lithostratigraphy model is reconstructed by integrating the analyses on FMS electrofacies, other physical property logs, and recovered cores. The new lithostratigraphy reveals that nearly 50 % of the in situ lithofacies in the Hole 1256D crust consists of either breccias or highly fractured lava flows, inferring that the shipboard stratigraphy with mostly massive flows is inaccurate. The meticulously deciphered lava morphology tie the lava deposition history in Hole 1256D to the East Pacific Rise surface volcanology, and with this, the upper ocean crustal construction processes in the Hole 1256D crust, from the spreading axis to the abyssal plain, can be proposed. Furthermore, the vacancy in the crustal matrix, where water and minerals can be stored and microbes can exist, is determined from the FMS images. The distribution and areas of the surface void calculated by ImageJ image processor reveals that the visible void in the 1256D crust vary 10 to 60 % depending on lithofacies, with the average of 37 %. This downhole distribution of the void areas also shows the positive correlation with previously observed lab-based porosity and 1-D sonic-log based fractional porosity data. Further study is in progress on scaling of the porosity structure from hand-specimen to crustal scales in the Hole 1256D crust: from the lab porosity data, to 1D sonic-log, to the areas of surface void detected observed in the FMS images, and ultimately to the vertical seismic experiments.
Nelson, Sven K.; Oliver, Melvin J.
2017-01-01
Drought is a serious problem that causes losses in crop-yield every year, but the mechanisms underlying how roots respond to water deficit are difficult to study under controlled conditions. Methods for assaying root elongation and architecture, especially for seedlings, are commonly achieved on artificial media, such as agar, moistened filter paper, or in hydroponic systems. However, it has been demonstrated that measuring root characteristics under such conditions does not accurately mimic what is observed when plants are grown in soil. Morphological changes in root behavior occur because of differences in solute diffusion, mechanical impedance, exposure to light (in some designs), and gas exchange of roots grown under these conditions. To address such deficiencies, we developed a quantitative method for assaying seedling root lengths and germination in soil using a plate-based approach with wheat as a model crop. We also further developed the method to include defined water deficits stress levels using the osmotic properties of polyethylene glycol (PEG). Seeds were sown into soil-filled vertical plates and grown in the dark. Root length measurements were collected using digital photography through the transparent lid under green lighting to avoid effects of white light exposure on growth. Photographs were analyzed using the cross-platform ImageJ plugin, SmartRoot, which can detect root edges and partially automate root detection for extraction of lengths. This allowed for quick measurements and straightforward and accurate assessments of non-linear roots. Other measurements, such as root width or angle, can also be collected by this method. An R function was developed to collect exported root length data, process and reformat the data, and output plots depicting root/shoot growth dynamics. For water deficit experiments, seedlings were transplanted side-by-side into well-watered plates and plates containing PEG solutions to simulate precise water deficits. PMID:28785272
Nelson, Sven K; Oliver, Melvin J
2017-01-01
Drought is a serious problem that causes losses in crop-yield every year, but the mechanisms underlying how roots respond to water deficit are difficult to study under controlled conditions. Methods for assaying root elongation and architecture, especially for seedlings, are commonly achieved on artificial media, such as agar, moistened filter paper, or in hydroponic systems. However, it has been demonstrated that measuring root characteristics under such conditions does not accurately mimic what is observed when plants are grown in soil. Morphological changes in root behavior occur because of differences in solute diffusion, mechanical impedance, exposure to light (in some designs), and gas exchange of roots grown under these conditions. To address such deficiencies, we developed a quantitative method for assaying seedling root lengths and germination in soil using a plate-based approach with wheat as a model crop. We also further developed the method to include defined water deficits stress levels using the osmotic properties of polyethylene glycol (PEG). Seeds were sown into soil-filled vertical plates and grown in the dark. Root length measurements were collected using digital photography through the transparent lid under green lighting to avoid effects of white light exposure on growth. Photographs were analyzed using the cross-platform ImageJ plugin, SmartRoot, which can detect root edges and partially automate root detection for extraction of lengths. This allowed for quick measurements and straightforward and accurate assessments of non-linear roots. Other measurements, such as root width or angle, can also be collected by this method. An R function was developed to collect exported root length data, process and reformat the data, and output plots depicting root/shoot growth dynamics. For water deficit experiments, seedlings were transplanted side-by-side into well-watered plates and plates containing PEG solutions to simulate precise water deficits.
NASA Astrophysics Data System (ADS)
Wheatland, Jonathan; Bushby, Andy; Droppo, Ian; Carr, Simon; Spencer, Kate
2015-04-01
Suspended estuarine sediments form flocs that are compositionally complex, fragile and irregularly shaped. The fate and transport of suspended particulate matter (SPM) is determined by the size, shape, density, porosity and stability of these flocs and prediction of SPM transport requires accurate measurements of these three-dimensional (3D) physical properties. However, the multi-scaled nature of flocs in addition to their fragility makes their characterisation in 3D problematic. Correlative microscopy is a strategy involving the spatial registration of information collected at different scales using several imaging modalities. Previously, conventional optical microscopy (COM) and transmission electron microscopy (TEM) have enabled 2-dimensional (2D) floc characterisation at the gross (> 1 µm) and sub-micron scales respectively. Whilst this has proven insightful there remains a critical spatial and dimensional gap preventing the accurate measurement of geometric properties and an understanding of how structures at different scales are related. Within life sciences volumetric imaging techniques such as 3D micro-computed tomography (3D µCT) and focused ion beam scanning electron microscopy [FIB-SEM (or FIB-tomography)] have been combined to characterise materials at the centimetre to micron scale. Combining these techniques with TEM enables an advanced correlative study, allowing material properties across multiple spatial and dimensional scales to be visualised. The aims of this study are; 1) to formulate an advanced correlative imaging strategy combining 3D µCT, FIB-tomography and TEM; 2) to acquire 3D datasets; 3) to produce a model allowing their co-visualisation; 4) to interpret 3D floc structure. To reduce the chance of structural alterations during analysis samples were first 'fixed' in 2.5% glutaraldehyde/2% formaldehyde before being embedding in Durcupan resin. Intermediate steps were implemented to improve contrast and remove pore water, achieved by the addition of heavy metal stains and washing samples in a series of ethanol solutions and acetone. Gross-scale characterisation involved scanning samples using a Nikon Metrology HM X 225 µCT. For micro-scale analysis a working surface was revealed by microtoming the sample. Ultrathin sections were then collected and analysed using a JEOL 1200 Ex II TEM, and FIB-tomography datasets obtained using an FEI Quanta 3D FIB-SEM. Finally, to locate the surface and relate TEM and FIB-tomography datasets to the original floc, samples were rescanned using the µCT. Image processing was initially conducted in ImageJ. Following this datasets were imported into Amira 5.5 where pixel intensity thresholding allowed particle-matrix boundaries to be defined. Using 'landmarks' datasets were then registered to enable their co-visualisation in 3D models. Analysis of registered datasets reveals the complex non-fractal nature of flocs, whose properties span several of orders of magnitude. Primary particles are organised into discrete 'bundles', the arrangement of which directly influences their gross morphology. This strategy, which allows the co-visualisation of spatially registered multi-scale 3D datasets, provides unique insights into the true nature floc which would other have been impossible.
Complex Contact Angles Calculated from Capillary Rise Measurements on Rock Fracture Faces
NASA Astrophysics Data System (ADS)
Perfect, E.; Gates, C. H.; Brabazon, J. W.; Santodonato, L. J.; Dhiman, I.; Bilheux, H.; Bilheux, J. C.; Lokitz, B. S.
2017-12-01
Contact angles for fluids in unconventional reservoir rocks are needed for modeling hydraulic fracturing leakoff and subsequent oil and gas extraction. Contact angle measurements for wetting fluids on rocks are normally performed using polished flat surfaces. However, such prepared surfaces are not representative of natural rock fracture faces, which have been shown to be rough over multiple scales. We applied a variant of the Wilhelmy plate method for determining contact angle from the height of capillary rise on a vertical surface to the wetting of rock fracture faces by water in the presence of air. Cylindrical core samples (5.05 cm long x 2.54 cm diameter) of Mancos shale and 6 other rock types were investigated. Mode I fractures were created within the cores using the Brazilian method. Each fractured core was then separated into halves exposing the fracture faces. One fracture face from each rock type was oriented parallel to a collimated neutron beam in the CG-1D imaging instrument at ORNL's High Flux Isotope Reactor. Neutron radiography was performed using the multi-channel plate detector with a spatial resolution of 50 μm. Images were acquired every 60 s after a water reservoir contacted the base of the fracture face. The images were normalized to the initial dry condition so that the upward movement of water on the fracture face was clearly visible. The height of wetting at equilibrium was measured on the normalized images using ImageJ. Contact angles were also measured on polished flat surfaces using the conventional sessile drop method. Equilibrium capillary rise on the exposed fracture faces was up to 8.5 times greater than that predicted for polished flat surfaces from the sessile drop measurements. These results indicate that rock fracture faces are hyperhydrophilic (i.e., the height of capillary rise is greater than that predicted for a contact angle of zero degrees). The use of complex numbers permitted calculation of imaginary contact angles for such surfaces. This analysis yielded a continuum of contact angles (real above, and imaginary below, zero degrees) that can be used to investigate relationships with properties such surface roughness and porosity. It should be noted these are preliminary, unreplicated results and further research will be needed to verify them and refine the approach.
NASA Astrophysics Data System (ADS)
Graham, N. A.
2014-12-01
Lassen Volcanic Center is the southernmost volcanic region in the Cascade volcanic arc formed by the Cascadia Subduction Zone. Lassen Peak last erupted in 1915 in an arc related event producing a black dacite material containing xenocrystic olivine grains with apparent orthopyroxene reaction rims. The reaction rims on these olivine grains are believed to have formed by reactions that ensued from a mixing/mingling event that occurred prior to eruption between the admixed mafic andesitic magma and a silicic dacite host material. Natural samples of the 1915 black dacite from Lassen Peak, CA were prepared into 15 polished thin sections and carbon coated for analysis using a FEI Quanta 250 Scanning Electron Microscope (SEM) to identify and measure mineral textures and disequilibrium reaction rims. Observed mineralogical textures related to magma mixing include biotite and amphibole grains with apparent dehydration/breakdown rims, pyroxene-rimmed quartz grains, high concentration of microlites in glass matrix, and pyroxene/amphibole reaction rims on olivine grains. Olivine dissolution is evidenced as increased iron concentration toward convolute edges of olivine grains as observed by Backscatter Electron (BSE) imagery and elemental mapping using NSS spectral imaging software. In an attempt to quantify the area of reaction rim growth on olivine grains within these samples, high-resolution BSE images of 30 different olivine grains were collected along with Energy-Dispersive X-Ray Spectroscopy (EDS) of different phases. Olivine cores and rims were extracted from BSE images using Photoshop and saved as separate image files. ImageJ software was used to calculate the area (μm2) of the core and rim of these grains. Average pyroxene reaction rim width for 30 grains was determined to be 11.68+/-1.65 μm. Rim widths of all 30 grains were averaged together to produce an overall average rim width for the Lassen Peak black dacite. By quantifying the reaction rims on olivine grains in the natural samples of Lassen Peak dacite as well as the bulk chemistry of the rock, this provides insight into the storage conditions of the magma chamber and the timing necessary for reactions to form these specific volcanic textures which in turn can be used as a basis for better understanding future experimental reconstruction of this magmatic system.
Bigras, Gilbert
2012-06-01
Color deconvolution relies on determination of unitary optical density vectors (OD(3D)) derived from pure constituent stains initially defined as intensity vectors in RGB space. OD(3D) can be defined in polar coordinates (phi, theta, radius); always being equal to one, radius can be ignored. Easier handling of unitary optical density 2D vectors (OD(2D)) is shown. OD(2D) pure stains used in anatomical pathology were assessed as centroid values (phi, theta) with a measure of variance: inertia based on arc lengths between centroid value and sampled points. These variables were plotted on a stereographic projection plane. In order to assess pure stains OD(2D), different methods of sampling RGB pixels were tested and compared: (2) direct sampling of nuclei from preparations using (a) composite H&E and (b) hematoxylin only and (2) for any pure stain RGB image, different associated 8-bit masks (saturation, brightness and RGB average) were used for sampling and compared. Behaviors of phi, theta and inertia were obtained by moving threshold in 8-bit mask histograms. Phi and theta stability were tested against variable light intensity during image acquisition and by using 2 different image acquisition systems. The more saturated RGB pixels are, the more stable phi, theta and inertia values are obtained. Different commercial hematoxylins have distinct OD(2D) characteristics. UltraView DAB stain shows high inertia and is angularly closer to usual counterstains than ultraView Red stain, which also has a lower inertia. Superior accuracy is expected from the latter stain. Phi and theta OD(2D) values are sensitive to light intensity variation, to the used imaging system and to the used objectives. An ImageJ plugin was designed to plot and interactively modify OD(2D) values with instant update of color deconvolution allowing heuristic segmentation. Utilization of polar OD(2D) eases statistical characterization of OD(3D) vectors: conditions of optimal sampling were demonstrated and various factors influencing OD(2D) stability were explored. Stereographic projection plane allows intuitive visualization of OD(3D) vectors as well as heuristic vectorial modification. All findings are not restricted to anatomical pathology but can be applied to bright field microscopy and subtractive color applications in general.
A "twisted" microfluidic mixer suitable for a wide range of flow rate applications.
Sivashankar, Shilpa; Agambayev, Sumeyra; Mashraei, Yousof; Li, Er Qiang; Thoroddsen, Sigurdur T; Salama, Khaled Nabil
2016-05-01
This paper proposes a new "twisted" 3D microfluidic mixer fabricated by a laser writing/microfabrication technique. Effective and efficient mixing using the twisted micromixers can be obtained by combining two general chaotic mixing mechanisms: splitting/recombining and chaotic advection. The lamination of mixer units provides the splitting and recombination mechanism when the quadrant of circles is arranged in a two-layered serial arrangement of mixing units. The overall 3D path of the microchannel introduces the advection. An experimental investigation using chemical solutions revealed that these novel 3D passive microfluidic mixers were stable and could be operated at a wide range of flow rates. This micromixer finds application in the manipulation of tiny volumes of liquids that are crucial in diagnostics. The mixing performance was evaluated by dye visualization, and using a pH test that determined the chemical reaction of the solutions. A comparison of the tornado-mixer with this twisted micromixer was made to evaluate the efficiency of mixing. The efficiency of mixing was calculated within the channel by acquiring intensities using ImageJ software. Results suggested that efficient mixing can be obtained when more than 3 units were consecutively placed. The geometry of the device, which has a length of 30 mm, enables the device to be integrated with micro total analysis systems and other lab-on-chip devices.
A “twisted” microfluidic mixer suitable for a wide range of flow rate applications
Sivashankar, Shilpa; Agambayev, Sumeyra; Mashraei, Yousof; Li, Er Qiang; Thoroddsen, Sigurdur T.; Salama, Khaled Nabil
2016-01-01
This paper proposes a new “twisted” 3D microfluidic mixer fabricated by a laser writing/microfabrication technique. Effective and efficient mixing using the twisted micromixers can be obtained by combining two general chaotic mixing mechanisms: splitting/recombining and chaotic advection. The lamination of mixer units provides the splitting and recombination mechanism when the quadrant of circles is arranged in a two-layered serial arrangement of mixing units. The overall 3D path of the microchannel introduces the advection. An experimental investigation using chemical solutions revealed that these novel 3D passive microfluidic mixers were stable and could be operated at a wide range of flow rates. This micromixer finds application in the manipulation of tiny volumes of liquids that are crucial in diagnostics. The mixing performance was evaluated by dye visualization, and using a pH test that determined the chemical reaction of the solutions. A comparison of the tornado-mixer with this twisted micromixer was made to evaluate the efficiency of mixing. The efficiency of mixing was calculated within the channel by acquiring intensities using ImageJ software. Results suggested that efficient mixing can be obtained when more than 3 units were consecutively placed. The geometry of the device, which has a length of 30 mm, enables the device to be integrated with micro total analysis systems and other lab-on-chip devices. PMID:27453767
Microstructural behavior of iron and bismuth added Sn-1Ag-Cu solder under elevated temperature aging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ali, Bakhtiar, E-mail: engrbakhtiaralikhan@gmail.com; Sabri, Mohd Faizul Mohd, E-mail: faizul@um.edu.my; Jauhari, Iswadi, E-mail: iswadi@um.edu.my
An extensive study was done to investigate the microstructural behavior of iron (Fe) and bismuth (Bi) added Sn-1Ag-0.5Cu (SAC105) under severe thermal aging conditions. The isothermal aging was done at 200 °C for 100 h, 200 h, and 300 h. Optical microscopy with cross-polarized light revealed that the grain size significantly reduces with Fe/Bi addition to the base alloy SAC105 and remains literally the same after thermal aging. The micrographs of field emission scanning electron microscopy (FESEM) with backscattered electron detector and their further analysis via imageJ software indicated that Fe/Bi added SAC105 showed a significant reduction in the IMCsmore » size (Ag{sub 3}Sn and Cu{sub 6}Sn{sub 5}), especially the Cu{sub 6}Sn{sub 5} IMCs, as well as β-Sn matrix and a refinement in the microstructure, which is due to the presence of Bi in the alloys. Moreover, their microstructure remains much more stable under severe thermal aging conditions, which is because of the presence of both Fe and Bi in the alloy. The microstructural behavior suggests that Fe/Bi modified SAC105 would have much improved reliability under severe thermal environments. These modified alloys also have relatively low melting temperature and low cost.« less
Rahman, Mohammad Bozlur; Kamal, Md Mostofa; Rijsselaere, Tom; Vandaele, Leen; Shamsuddin, Mohammed; Van Soom, Ann
2014-10-01
Shortly after penetration of the oocyte, sperm DNA is actively demethylated, which is required for totipotent zygotic development. Aberrant DNA methylation is thought to be associated with altered chromatin condensation of spermatozoa. The objectives of this study were to investigate the dynamics of DNA methylation reprogramming in the paternal pronucleus and subsequent fertilisation potential of heat-stressed bull spermatozoa having altered chromatin condensation. Hence, bovine zygotes (n=1239) were collected at three different time points (12, 18 and 24h post insemination, hpi), and stained with an antibody against 5-methylcytosine. Fluorescence intensities of paternal and maternal pronuclei were measured by ImageJ. DNA methylation patterns in paternal pronuclei derived from heat-stressed spermatozoa did not differ between time points (P>0.05), whereas control zygotes clearly showed demethylation and de novo methylation at 18 and 24hpi, respectively. Moreover, heat-stressed spermatozoa showed a highly reduced (P<0.01) fertilisation rate compared with non-heat-stressed or normal control spermatozoa (53.7% vs 70.2% or 81.5%, respectively). Our data show that the normal pattern of active DNA demethylation followed by de novo methylation in the paternal pronucleus is perturbed when oocytes are fertilised with heat-stressed spermatozoa, which may be responsible for decreased fertilisation potential.
Pronko, Alexander J; Perlman, Benjamin M; Ashley-Ross, Miriam A
2013-11-01
Mangrove rivulus (Kryptolebias marmoratus) are small fusiform teleosts (Cyprinodontiformes) with the ability to locomote on land, despite lacking apparent morphological adaptations for terrestrial movement. Rivulus will leave their aquatic habitat for moist, terrestrial environments when water conditions are poor, or, as we show here, to capture terrestrial insects. Specimens were conditioned to eat pinhead crickets on one side of their aquaria. After 2 weeks of conditioning, a barrier with a slope of 15 deg was partially submerged in the middle of the tank, forcing the fish to transition from water to land and back into water in order to feed. Kinematics during the transition were recorded using Fastec high-speed video cameras (125-250 frames s(-1)). Videos were analyzed using Didge and ImageJ software programs. Transition behaviors were characterized and analyzed according to their specific type. Body oscillation amplitude and wave duration were quantified for movements along the substrate, along with initial velocity for launching behaviors. Kryptolebias marmoratus used a diverse suite of behaviors to transition from water to land. These behaviors can be categorized as launches, squiggles and pounces. Prey were captured terrestrially and brought underwater for consumption. Kryptolebias marmoratus's suite of behaviors represents a novel solution to non-tetrapodal terrestrial transition, which suggests that fishes may have been able to exploit land habitats transiently, without leaving any apparent evidence in the fossil record.
Vadivelu, Jamuna; Vellasamy, Kumutha Malar; Thimma, Jaikumar; Mariappan, Vanitha; Kang, Wen-Tyng; Choh, Leang-Chung; Shankar, Esaki M; Wong, Kum Thong
2017-01-01
During infection, successful bacterial clearance is achieved via the host immune system acting in conjunction with appropriate antibiotic therapy. However, it still remains a tip of the iceberg as to where persistent pathogens namely, Burkholderia pseudomallei (B. pseudomallei) reside/hide to escape from host immune sensors and antimicrobial pressure. We used transmission electron microscopy (TEM) to investigate post-mortem tissue sections of patients with clinical melioidosis to identify the localisation of a recently identified gut microbiome, B. pseudomallei within host cells. The intranuclear presence of B. pseudomallei was confirmed using transmission electron microscopy (TEM) of experimentally infected guinea pig spleen tissues and Live Z-stack, and ImageJ analysis of fluorescence microscopy analysis of in vitro infection of A549 human lung epithelial cells. TEM investigations revealed intranuclear localization of B. pseudomallei in cells of infected human lung and guinea pig spleen tissues. We also found that B. pseudomallei induced actin polymerization following infection of A549 human lung epithelial cells. Infected A549 lung epithelial cells using 3D-Laser scanning confocal microscopy (LSCM) and immunofluorescence microscopy confirmed the intranuclear localization of B. pseudomallei. B. pseudomallei was found within the nuclear compartment of host cells. The nucleus may play a role as an occult or transient niche for persistence of intracellular pathogens, potentially leading to recurrrent episodes or recrudescence of infection.
Vadivelu, Jamuna; Vellasamy, Kumutha Malar; Thimma, Jaikumar; Mariappan, Vanitha; Kang, Wen-Tyng; Choh, Leang-Chung; Wong, Kum Thong
2017-01-01
Background During infection, successful bacterial clearance is achieved via the host immune system acting in conjunction with appropriate antibiotic therapy. However, it still remains a tip of the iceberg as to where persistent pathogens namely, Burkholderia pseudomallei (B. pseudomallei) reside/hide to escape from host immune sensors and antimicrobial pressure. Methods We used transmission electron microscopy (TEM) to investigate post-mortem tissue sections of patients with clinical melioidosis to identify the localisation of a recently identified gut microbiome, B. pseudomallei within host cells. The intranuclear presence of B. pseudomallei was confirmed using transmission electron microscopy (TEM) of experimentally infected guinea pig spleen tissues and Live Z-stack, and ImageJ analysis of fluorescence microscopy analysis of in vitro infection of A549 human lung epithelial cells. Results TEM investigations revealed intranuclear localization of B. pseudomallei in cells of infected human lung and guinea pig spleen tissues. We also found that B. pseudomallei induced actin polymerization following infection of A549 human lung epithelial cells. Infected A549 lung epithelial cells using 3D-Laser scanning confocal microscopy (LSCM) and immunofluorescence microscopy confirmed the intranuclear localization of B. pseudomallei. Conclusion B. pseudomallei was found within the nuclear compartment of host cells. The nucleus may play a role as an occult or transient niche for persistence of intracellular pathogens, potentially leading to recurrrent episodes or recrudescence of infection. PMID:28045926
Cehreli, Zafer C; Isbitiren, Beste; Sara, Sezgi; Erbas, Gizem
2011-09-01
Revascularization is an emerging regenerative treatment protocol with little published data available in immature molar teeth. The present case series demonstrates the outcome of revascularization treatment with intracanal medicament of calcium hydroxide in immature necrotic molars. Immature necrotic permanent first molars (n = 6) of patients 8-11 years old were treated by a revascularization protocol that used 2.5% NaOCl irrigation, medication with calcium hydroxide placed in the coronal third of the root canals, induction of apical bleeding, and coronal sealing with white mineral trioxide aggregate. Among the treated teeth, 4 molars had undergone prior root canal instrumentation by the referring dentists. National Institutes of Health Image-J program with TurboReg plug-in was used for standardization of the radiographs and to determine the increase in root length and root width. After a follow-up period of 10 months, all teeth demonstrated radiographic evidence of complete periapical healing, progressive thickening of dentinal walls, and continued apical development in the absence of clinical symptoms. Two uninstrumented molars showed a positive response to cold testing at 9 months. On the basis of a follow-up period of 10 months, the present cases demonstrate a favorable outcome of the revascularization procedure in immature necrotic molars by using calcium hydroxide medication in the coronal third of the root canals. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
An In-Situ Root-Imaging System in the Context of Surface Detection of CO2
NASA Astrophysics Data System (ADS)
Apple, M. E.; Prince, J. B.; Bradley, A. R.; Zhou, X.; Lakkaraju, V. R.; Male, E. J.; Pickles, W.; Thordsen, J. J.; Dobeck, L.; Cunningham, A.; Spangler, L.
2009-12-01
Carbon sequestration is a valuable method of spatially confining CO2 belowground. The Zero Emissions Research Technology, (ZERT), site is an experimental facility in a former agricultural field on the Montana State University campus in Bozeman, Montana, where CO2 was experimentally released at a rate of 200kg/day in 2009 into a 100 meter underground injection well running parallel to the ground surface. This injection well, or pipe, has deliberate leaks at intervals, and CO2 travels from these leaks upward to the surface of the ground. The ZERT site is a model system designed with the purpose of testing methods of surface detection of CO2. One important aspect of surface detection is the determination of the effects of CO2 on the above and belowground portions of plants growing above sequestration fields. At ZERT, these plants consist of a pre-existing mixture of herbaceous species present at the agricultural field. Species growing at the ZERT site include several grasses, Dactylis glomerata (Orchard Grass), Poa pratensis (Kentucky Bluegrass), and Bromus japonicus (Japanese Brome); the nitrogen-fixing legumes Medicago sativa, (Alfalfa), and Lotus corniculatus, (Birdsfoot trefoil); and an abundance of Taraxacum officinale, (Dandelion). Although the aboveground parts of the plants at high CO2 are stressed, as indicated by changes in hyperspectral plant signatures, leaf fluorescence and leaf chlorophyll content, we are interested in determining whether the roots are also stressed. To do so, we are combining measurements of soil conductivity and soil moisture with root imaging. We are using an in-situ root-imaging system manufactured by CID, Inc. (Camas, WA), along with image analysis software (Image-J) to analyze morphometric parameters in the images and to determine what effects, if any, the presence of leaking and subsequently upwelling CO2 has on the phenology of root growth, growth and turnover of individual fine and coarse roots, branching patterns, and root density and depth in the soil. We drilled three holes for the plexiglass root-imaging tubes in December 2008 and installed the tubes post-thaw in May 2009, with the initial set of images taken in July 2009 on the day preceding the 4-week long CO2 injection. We collected images weekly thereafter until late August 2009 by inserted a rotating camera into the tube and photographing at 10 cm intervals from the surface to a depth of 75-80 cm. By August 2009, roots were visible at 80 cm below ground. The root-imaging tubes will remain in place so that we can track the roots through the upcoming years at the ZERT site. Each year, we anticipate gathering images in the fall, winter, before the beginning of root growth in the spring, as well as during the summer injections of CO2. The information gained from these images will be useful in linking above and belowground responses of plants to CO2.
NASA Astrophysics Data System (ADS)
Yu, E.; Wang, C.; Hinnov, L. A.; Wu, H.
2014-12-01
The quasi-periodic, ca. 2-7 year El Niño Southern Oscillation (ENSO) phenomenon globally influences the inter-annual variability of temperature and precipitation. Global warming may increase the frequency of extreme ENSO events. Although the Cretaceous plate tectonic configuration was different from today, the sedimentary record suggests that ENSO-type oscillations had existed at the time of Cretaceous greenhouse conditions. Cored Cretaceous lacustrine sediments from the Songliao Basin in Northeast China (SK-1 cores from the International Continental Drilling Program) potentially offer a partially varved record of Cretaceous paleoclimate. Fourteen polished thin sections from the depth interval 1096.12-1096.53 m with an age of 84.4 Ma were analyzed by optical and scanning electron microscopy (SEM). ImageJ software was applied to extract gray scale curves from optical images at pixel resolution. We tracked minimum values of the gray scale curves to estimate the thickness of each lamina. Five sedimentary structures were recognized: flaser bedding, wavy bedding, lenticular bedding, horizontal bedding, and massive layers. The mean layer thicknesses with different sedimentary structures range from 116 to 162mm, very close to the mean sedimentation rate estimated for this sampled interval, 135mm/year, indicating that the layers bounded by pure clay lamina with the minimum gray values are varves. SEM images indicate that a varve is composed, in succession, of one lamina rich in coarse silt, one lamina rich in fine silt, one clay-rich lamina with some silt, and one clay-rich lamina. This suggests that a Cretaceous year featured four distinct depositional seasons, two of which were rainy and the others were lacking precipitation. Spectral analysis of extended intervals of the tuned gray scale curve indicates the presence of inter-annual periodicities of 2.2-2.7 yr, 3.5-6.1 year, and 10.1-14.5 year consistent with those of modern ENSO cycles and solar cycles, as well as those recognized in the Cretaceous Arctic and Marca Shale of California.
Leitritz, Martin A; Ziemssen, Focke; Voykov, Bogomil; Dimopoulos, Spyridon; Zobor, Ditta; Bartz-Schmidt, Karl U; Gelisken, Faik
2014-08-01
To analyze the foveal surface using binary image analysis after spectral-domain optical coherence tomography (SD-OCT) following 23-gauge macular surgery in epiretinal membranes (ERM) using either air tamponade (AIR) or balanced salt solution (BSS). One hundred twenty-four eyes (124 patients) with ERM that had undergone membrane peeling with installation of air or BSS were analyzed retrospectively. Ophthalmic examination was performed at baseline and 3 months. The foveal area and surface symmetry, area matched thickness, area matched contour, and best-corrected visual acuity (BCVA). The OCT images were analyzed after binary conversion with ImageJ software. Eighty eyes (80 patients) of 124 screened patients were included (AIR group: 39 patients, BSS group: 41 patients). Median follow-up time was 14 weeks (range, 9-19 weeks). Three months after surgery, the median horizontal area decreased significantly in both groups (p < 0.0001). At follow-up, the foveal surface symmetry values for the BSS group (median, 22.73 μm, range, 0-153) were significantly lower than for the AIR group (median, 23.95 μm, range, 0-160.43) (p < 0.0001). The area-matched thickness increased significantly in both groups (p < 0.001). The AIR group showed a significant increase of the area matched contour for the nasal located measurement-areas N1 (p < 0.0003), N2 (p < 0.0079), N3 (p < 0.007). The BSS group showed a significant increase of the area-matched contour for the measurement areas N1 (p < 0.019), N2 (p < 0.0014), and N4 (p < 0.022). After surgery, median BCVA for both groups increased significantly to 0.3 logMAR. The analysis of early contour changes after ERM surgery was technically possible. Long-term data have to be looked at before the clinical impact of this methodology can be estimated. Although there were no big differences between both groups (AIR vs. BSS), this could change within a longer and more representative follow-up.
NASA Astrophysics Data System (ADS)
Casey, Meghan E.
Stem cells are widely used in the area of tissue engineering. The ability of cells to interact with materials on the nano- and micro- level is important in the success of the biomaterial. It is well-known that cells respond to their micro- and nano-environments through a process termed chemo-mechanotransduction. It is important to establish standard protocols for cellular experiments, as chemical modifications to maintenance environments can alter long-term research results. In this work, the effects of different media compositions on human mesenchymal stem cells (hMSCs) throughout normal in vitro maintenance are investigated. Changes in RNA regulation, protein expression and proliferation are studied via quantitative polymerase chain reaction (qPCR), immunocytochemistry (ICC) and cell counts, respectively. Morphological differences are also observed throughout the experiment. Results of this study illustrate the dynamic response of hMSC maintenance to differences in growth medium and passage number. These experiments highlight the effect growth medium has on in vitro experiments and the need of consistent protocols in hMSC research. A substantial opportunity exists in neuronal research to develop a material platform that allows for both the proliferation and differentiation of stem cells into neurons and the ability to quantify the secretome of neuronal cells. Anodic aluminum oxide (AAO) membranes are fabricated in a two-step anodization procedure where voltage is varied to control the pore size and morphology of the membranes. C17.2 neural stem cells are differentiated on the membranes via serum-withdrawal. Cellular growth is characterized by scanning electron microscopy (SEM), ICC and qPCR. ImageJ software is used to obtain phenotypic cell counts and neurite outgrowth lengths. Results indicate a highly tunable correlation between AAO nanopore sizes and differentiated cell populations. By selecting AAO membranes with specific pore size ranges, control of neuronal network density and neurite outgrowth length is achievable. To understand differentiation marker expressions in C17.2 NSCs and how material stiffness affects differentiation, cells are cultured on substrates of varying stiffness. qPCR is used to analyze neural stem cell, neural progenitor cell, neuron-restricted progenitor and differentiated post-mitotic neuronal cell RNA expression. Results suggest a relationship between material stiffness and neuronal development in C17.2 neural stem cells.
NASA Astrophysics Data System (ADS)
Burnett, C. T.; Patwardhan, K.
2016-12-01
We present results from experimental models of Kīlauea Iki lava lake with the goal of reproducing the S-shaped vertical distribution profile of phenocrysts in the solidifying lava lake. In November-December 1959, lava from a two-week long eruption at the summit of Kīlauea Volcano flowed into the adjoining Kīlauea Iki crater filling it with a lake of lava approximately 640 m across and 135 m deep. The erupted picritic lava contained approximately 17 modal % olivine phenocrysts (Garcia, 2003). As the lava lake filled most of the phenocrysts sank towards the lower parts of the lake while some were captured in the upper crust. This resulted in an S-shaped vertical profile with an olivine-depleted (1-3 % olivine) upper part and an olivine-enriched (up to 40 % olivine) lower part (Helz, 1989). In our experiments, molten paraffin wax, extra-fine craft glitter, and aluminum foil pans/bowls are used as analogs for magma, olivine phenocrysts, and Kīlauea Iki pit crater respectively. A molten paraffin-glitter mixture at approximately 54°C is stirred/poured into the crater to create the lake, and then frozen. Cross-sections of the solidified lake are photographed and imported into ImageJ to analyze the final distribution of glitter particles at various depths. This distribution depends primarily upon the competition between settling rate vs. solidification time. Particle settling rate is controlled by glitter-paraffin density difference and paraffin viscosity. Solidification time varies with initial paraffin temperature, aspect ratio of the model lake, and ambient temperature. Vertical profiles of several solidified lava lake models reveal a glitter particle (phenocryst) distribution similar to the S-shaped characteristic profile recorded at Kīlauea Iki. In effect, our lava lake models recreate the dynamic process of emplacement of crystal-laden magma with subsequent settling of these crystals to produce a phenocryst-enriched layer near the bottom. A similar process occurring in intrusions formed by emplacement of one or more crystal-laden magma batches may result in the development of cumulate layers. Our experimental methods and efforts in recreating the S-shaped profile in Kīlauea Iki may be used as a starting point to model more complex cumulate intrusions. (Special thanks to Prof. Shafiul Chowdhury)
Catalytic Degradation of Dichlorvos Using Biosynthesized Zero Valent Iron Nanoparticles.
Mehrotra, Neha; Tripathi, Ravi Mani; Zafar, Fahmina; Singh, Manoj Pratap
2017-06-01
The removal of dichlorvos contamination from water is a challenging task because of the presence of direct carbon to phosphorous covalent bond, which makes them resistant to chemical and thermal degradation. Although there have been reports in the literature for degradation of dichlorvos using nanomaterials, those are based on photocatalysis. In this paper, we report a simple and rapid method for catalytic degradation of dichlorvos using protein-capped zero valent iron nanoparticles (FeNPs). We have developed an unprecedented reliable, clean, nontoxic, eco-friendly, and cost-effective biological method for the synthesis of uniformly distributed FeNPs. Yeast extract was used as reducing and capping agent in the synthesis of FeNPs, and synthesized particles were characterized by the UV-visible spectroscopy, X -ray diffraction, Fourier transform infrared spectroscopy (FTIR), and transmission electron microscopy (TEM). TEM micrographs reveal that the nanoparticles size is distributed in the range of 2-10 nm. Selected area electron diffraction pattern shows the polycrystalline rings of FeNPs. The mean size was found to be 5.006 nm from ImageJ. FTIR spectra depicted the presence of biomolecules, which participated in the synthesis and stabilization of nanoparticles. As synthesized, FeNPs were used for the catalytic degradation of dichlorvos in aqueous medium. The degradation activity of the FeNPs has been investigated by the means of incubation time effect, oxidant effect, and nanoparticle concentration effect. The ammonium molybdate test was used to confirm the release of phosphate ions during the interaction of dichlorvos with FeNPs.
Size of the Lesions of Superficial Punctate Keratitis in Dry Eye Syndrome Observed With a Slit Lamp.
Courrier, Emilie; Lépine, Thierry; Hor, Guillaume; Fournier, Corinne; He, Zhiguo; Chikh, Mehdi; Urrea, Caroline; Al Anazi, Fahran-Falgi; Thuret, Gilles; Gain, Philippe
2016-07-01
To evaluate the size distribution of epithelial lesions of superficial punctate keratitis (SPK) in dry eye after staining of the ocular surface by sodium fluorescein. Fluorescein was instilled in 10 patients with dry eye graded using the Oxford Scheme. Pictures were taken using a standard Topcon slit lamp with cobalt blue light, without barrier filter. Two magnifications (×10 and ×16) were used and calibrated using a certified standard reference grating, allowing the diameter of the observed objects to be determined with ImageJ software. The most visible and isolated SPK lesions (green dots) were selected. The size of 254 SPK lesions was measured by tracing the irradiance profile and manually measuring the full width at half maximum. For all patients, with the 2 magnifications combined, the median diameter was 20.9 μm (15.2-26.6 μm, 10-90 percentile). There was a significant difference between the size of SPK lesions measured with ×10 and ×16 magnifications, respectively, 24.3 μm (18.2-29.8) versus 19.0 μm (15.2-26.6) (P < 0.001). Lesions seem to be smaller than normal superficial epithelial cells (which are approximately 25 × 50 μm) and might correspond to the staining of dying shrunken cells, according to recent investigations. These new quantitative data will help in developing automated recognition algorithms to obtain reliable objective classification of corneal staining.
Towards the development of a triple SMA actuated vertical tube
NASA Astrophysics Data System (ADS)
Karimi, Saeed; Konh, Bardia; Seidi, Ebrahim
2018-03-01
In this work an active vertically hung tube has been designed, fabricated and tested. The active tube was made of three separate 3D printed parts assembled and glued together. Shape Memory Alloy (SMA) wires were embedded as actuators in the body of the tube to privilege from their robust actuation and high energy density. Three SMA wires were trained and installed evenly on the exterior peripheral side of the tubes to realize motion in multiple directions. A deadweight was hung to one end of the tube to exert a certain amount of pre-stress on actuators. This design offers a restricted actuation because the two wires on the opposite side always resist the intended deflection. Hence, for a proper actuation, each wire was stressed to a certain level to exhibit either expansion or contraction upon demand. This amount of stress was selected based on rigorous experimental data. Power supply units were integrated and linked to a python program to control the amount of power passed through each SMA wire. The active tube was tested, and its movement was captured via a camera and analyzed by ImageJ software for the two cases free of stress and with an applied external load. The electrical resistance of the each SMA wire was measured and used for controlling the tube's deflection in each direction. This work demonstrated the feasibility of using three evenly distributed SMA wires on a tube to create motion in 3D direction.
Tsai, Hsin-Yi; Vats, Kanika; Yates, Matthew Z.; Benoit, Danielle S. W.
2013-01-01
Thermoresponsive poly(N-isopropyl acrylamide) (PNIPAM) microgels were patterned on polystyrene substrates via dip coating, creating cytocompatible substrates that provided spatial control over cell adhesion. This simple dip coating method, which exploits variable substrate withdrawal speeds form particle suspension formed stripes of densely-packed PNIPAM microgels, while spacings between the stripes contained sparsely-distributed PNIPAM microgels. The assembly of three different PNIPAM microgel patterns, namely patterns composed of 50 μm stripes/50 μm spacings, 50 μm stripes/100 μm spacings, and 100 μm stripes/100 μm spacings was verified using high-resolution optical micrographs and ImageJ analysis. PNIPAM microgels existed as monolayers within stripes and spacings, as revealed by atomic force microscopy (AFM). Upon cell seeding on PNIPAM micropatterned substrates, NIH3T3 fibroblast cells preferentially adhered within spacings to form cell patterns. Three days after cell seeding, cells proliferated to form confluent cell layers. The thermoresponsiveness of the underlying PNIPAM microgels was then utilized to recover fibroblast cell sheets from substrates simply by lowering the temperature, without disrupting the underlying PNIPAM microgel patterns. Harvested cell sheets similar to these have been used for multiple tissue engineering applications. Also, this simple, low cost, template-free dip coating technique can be utilized to micropattern multifunctional PNIPAM microgels, generating complex stimuli-responsive substrates to study cell-material interactions and allow drug delivery to cells in a spatially and temporally-controlled manners. PMID:23968193
Angular photogrammetric analysis of the soft tissue profile in 12-year-old southern Chinese.
Leung, Cindi Sy; Yang, Yanqi; Wong, Ricky Wk; Hägg, Urban; Lo, John; McGrath, Colman
2014-12-24
To quantify average angular measurements that define the soft tissue profiles of 12-year-old southern Chinese and to determine gender differences. A random population sample of 514 12-year-old children was recruited (about 10% of a Hong Kong Chinese birth cohort). Photographs were taken in natural head posture and 12 soft tissue landmarks were located on the photos to measure 12 angular measurements using ImageJ (V1.45s) for Windows. Approximately 10% of photographs were reanalyzed and method error was calculated. Angular norm values for the 12 parameters were determined and gender differences were assessed using 2 sample T-test with 95% confidence interval. The response rate was 54.1% (278/514). Norm values for the 12 angular measurements were generated. The greatest variability was found for the nasolabial (Cm-Sn-Ls) and labiomental (Li-Sm-Pg) angles. Gender differences were found in 4 angular parameters: vertical nasal angle (N-Prn/TV) (p < 0.05), cervicomental angle (G-Pg/C-Me) (p < 0.001), facial convexity angle (G-Sn-Pg) (p < 0.01) and total facial convexity angle (G-Prn-Pg)(p < 0.01). Norm values for 12 angular measurements among 12-year-old southern Chinese children were provided and some variability noted. Gender differences were apparent in several angular measurements. This study has implications in developing norm values for southern Chinese and for comparison with other ethnic groups.
Heiat, Mohammad; Ranjbar, Reza; Latifi, Ali Mohammad; Rasaee, Mohammad Javad; Farnoosh, Gholamreza
2017-07-01
Asymmetric PCR, a simple method to generate single-stranded DNA (ssDNA) aptamers in systematic evaluation of ligand by exponential enrichments rounds, is coupled with limitations. We investigated the essential strategies for optimization of conditions to perform a high-quality asymmetric PCR. Final concentrations of primers and template, the number of PCR cycles, and annealing temperature were selected as optimizing variables. The qualities of visualized PCR products were analyzed by ImageJ software. The highest proportion of interested DNA than unwanted products was considered as optimum conditions. Results revealed that the best values for primers ratio, final template concentration, annealing temperature, and PCR cycles were, respectively, 30:1, 1 ng/μL, 55 °C, and 20 cycles for the first and 50:1, 2 ng/μL, 59 °C, and 20 cycles for other rounds. No significant difference was found between optimized asymmetric PCR results in the rounds of two to eight (P > 0.05). The ssDNA quality in round 10 was significantly better than other rounds (P < 0.05). Generally, the ssDNA product with less dimers, double-stranded DNA (dsDNA), and smear are preferable. The dsDNA contamination is the worst, because it can act as antidote and inhibits aptameric performance. Therefore, to choose the best conditions, the lower amount of dsDNA is more important than other unwanted products. © 2016 International Union of Biochemistry and Molecular Biology, Inc.
Majid, Imran; Haq, Inaamul; Imran, Saher; Keen, Abid; Aziz, Khalid; Arif, Tasleem
2016-01-01
Background: Melasma Area and Severity Index (MASI), the scoring system in melasma, needs to be refined. Aims and Objectives: To propose a more practical scoring system, named as Melasma Severity Index (MSI), for assessing the disease severity and treatment response in melasma. Materials and Methods: Four dermatologists were trained to calculate MASI and also the proposed MSI scores. For MSI, the formula used was 0.4 (a × p2) l + 0.4 (a × p2) r + 0.2 (a × p2) n where “a” stands for area, “p” for pigmentation, “l” for left face, “r” for right face, and “n” for nose. On a single day, 30 enrolled patients were randomly examined by each trained dermatologist and their MASI and MSI scores were calculated. Next, each rater re-examined every 6th patient for repeat MASI and MSI scoring to assess intra- and inter-rater reliability of MASI and MSI scores. Validity was assessed by comparing the individual scores of each rater with objective data from mexameter and ImageJ software. Results: Inter-rater reliability, as assessed by intraclass correlation coefficient, was significantly higher for MSI (0.955) as compared to MASI (0.816). Correlation of scores with objective data by Spearman's correlation revealed higher rho values for MSI than for MASI for all raters. Limitations: Sample population belonged to a single ethnic group. Conclusions: MSI is simpler and more practical scoring system for melasma. PMID:26955093
Human placental PPAR-γ and SOX-2 expression in serologically proved toxoplasmosis.
Hasby Saad, M; El-Anwar, N; Lotfy, S; Fouda, M; Hasby, E
2018-06-01
To explore PPAR-γ and SOX-2 transcription factors expression in placenta according to maternal anti-Toxoplasma gondii serological profile during pregnancy and pregnancy outcome. The study included 240 placentas, grouped according to IgM and IgG serostatus and then subgrouped according to pregnancy outcome that varied between miscarriages, premature labour, stillbirth and giving birth to CNS anomaly or apparently healthy neonates. Samples were H&E stained and histopathologically scored blindly. PPAR-γ expression was measured by ELISA, while SOX-2-positive nuclei were stained immunohistochemically to be calculated by ImageJ. The mean pathological score was significantly higher in IgM+ve and IgG rising than IgG-ve and persistent low groups. Former groups showed significantly higher PPAR-γ (mean = 258.63, 227.11). However, PPAR-γ was higher in apparently healthy neonate subgroups. SOX-2 was significantly lower in IgM+ve and IgG rising groups (mean = 12.87, 43.13) and associated with obvious fibrosis. SOX-2 lowest count was in CNS anomaly subgroup. PPAR-γ and SOX-2 changes may give clues of how Toxoplasma induces pathogenesis during vertical transmission. Triggering PPAR-γ expression may be a tool to downregulate the inflammatory response and establish a metabolically permissive cellular environment for Toxoplasma persistence. Low SOX-2 is suspected to disturb placental mesenchymal stem cells pluripotency and neuroectoderm development. © 2018 John Wiley & Sons Ltd.
Age-Related Changes in Pharyngeal Lumen Size: A Retrospective MRI Analysis.
Molfenter, Sonja M; Amin, M R; Branski, R C; Brumm, J D; Hagiwara, M; Roof, S A; Lazarus, C L
2015-06-01
Age-related loss of muscle bulk and strength (sarcopenia) is often cited as a potential mechanism underlying age-related changes in swallowing. Our goal was to explore this phenomenon in the pharynx, specifically, by measuring pharyngeal wall thickness and pharyngeal lumen area in a sample of young versus older women. MRI scans of the neck were retrospectively reviewed from 60 women equally stratified into three age groups (20s, 60s, 70+). Four de-identified slices were extracted per scan for randomized, blinded analysis: one mid-sagittal and three axial slices were selected at the anterior inferior border of C2 and C3, and at the pit of the vallecula. Pixel-based measures of pharyngeal wall thickness and pharyngeal lumen area were completed using ImageJ and then converted to metric units. Measures of pharyngeal wall thickness and pharyngeal lumen area were compared between age groups with one-way ANOVAs using Sidak adjustments for post-hoc pairwise comparisons. A significant main effect for age was observed across all variables whereby pharyngeal wall thickness decreased and pharyngeal lumen area increased with advancing age. Pairwise comparisons revealed significant differences between 20s versus 70+ for all variables and 20s versus 60s for all variables except those measured at C2. Effect sizes ranged from 0.54 to 1.34. Consistent with existing sacropenia literature, the pharyngeal muscles appear to atrophy with age and consequently, the size of the pharyngeal lumen increases.
3D-printing of undisturbed soil imaged by X-ray
NASA Astrophysics Data System (ADS)
Bacher, Matthias; Koestel, John; Schwen, Andreas
2014-05-01
The unique pore structures in Soils are altered easily by water flow. Each sample has a different morphology and the results of repetitions vary as well. Soil macropores in 3D-printed durable material avoid erosion and have a known morphology. Therefore potential and limitations of reproducing an undisturbed soil sample by 3D-printing was evaluated. We scanned an undisturbed soil column of Ultuna clay soil with a diameter of 7 cm by micro X-ray computer tomography at a resolution of 51 micron. A subsample cube of 2.03 cm length with connected macropores was cut out from this 3D-image and printed in five different materials by a 3D-printing service provider. The materials were ABS, Alumide, High Detail Resin, Polyamide and Prime Grey. The five print-outs of the subsample were tested on their hydraulic conductivity by using the falling head method. The hydrophobicity was tested by an adapted sessile drop method. To determine the morphology of the print-outs and compare it to the real soil also the print-outs were scanned by X-ray. The images were analysed with the open source program ImageJ. The five 3D-image print-outs copied from the subsample of the soil column were compared by means of their macropore network connectivity, porosity, surface volume, tortuosity and skeleton. The comparison of pore morphology between the real soil and the print-outs showed that Polyamide reproduced the soil macropore structure best while Alumide print-out was the least detailed. Only the largest macropore was represented in all five print-outs. Printing residual material or printing aid material remained in and clogged the pores of all print-out materials apart from Prime Grey. Therefore infiltration was blocked in these print-outs and the materials are not suitable even though the 3D-printed pore shapes were well reproduced. All of the investigated materials were insoluble. The sessile drop method showed angles between 53 and 85 degrees. Prime Grey had the fastest flow rate; the other conducting materials had slow or non-reproducible flow rates. Since only Prime Grey was able to print-out the largest macropore in a discontinuous way, the morphological differences between the five print-outs were not evaluated. Each material has its limitations but only Prime Greys morphology was sufficiently printed and no clogging with residual material occurred. Polyamide and High Detail Resin had clogged pores but were matching the soil's macropore morphology better but further research on removal of residual material blocking pores is needed before they are useable.
Analysis of Benthic Foraminiferal Size Change During the Eocene-Oligocene Transition
NASA Astrophysics Data System (ADS)
Zachary, W.; Keating-Bitonti, C.
2017-12-01
The Eocene-Oligocene transition is a significant global cooling event with the first growth of continental ice on Antarctica. In the geologic record, the size of fossils can be used to indirectly observe how organisms respond to climate change. For example, organisms tend to be larger in cooler environments as a physiological response to temperature. This major global cooling event should influence organism physiology, resulting in significant size trends observed in the fossil record. Benthic foraminifera are protists and those that grow a carbonate shell are both well-preserved and abundant in marine sediments. Here, we used the foraminiferal fossil record to study the relationship between their size and global cooling. We hypothesize that cooler temperatures across the Eocene-Oligocene boundary promoted shell size increase. To test this hypothesis, we studied benthic foraminifera from 10 deep-sea cores drilled at Ocean Drilling Program Site 744, located in the southern Indian Ocean. We washed sediment samples over a 63-micron sieve and picked foraminifera from a 125-micron sieve. We studied the benthic foraminiferal genus Cibicidoides and its size change across this cooling event. Picked specimens were imaged and we measured the diameter of their shells using "imageJ". Overall, we find that Cibicidoides shows a general trend of increasing size during this transition. In particular, both the median and maximum sizes of Cibicidoides increase from the Eocene into the Oligocene. We also analyzed C. pachyderma and C. mundulus for size trends. Although both species increase in median size across the boundary, only C. pachyderma shows a consistent trend of increasing maximum, median, and minimum shell diameter. After the Eocene-Oligocene boundary, we observe that shell diameter decreases following peak cooling and that foraminiferal sizes remain stable into the early Oligocene. Therefore, the Eocene-Oligocene cooling event appears to have strong influence on shell size.
Zorn-Kruppa, Michaela; Houdek, Pia; Wladykowski, Ewa; Engelke, Maria; Bartok, Melinda; Mewes, Karsten R.; Moll, Ingrid; Brandner, Johanna M.
2014-01-01
The depth of injury (DOI) is a mechanistic correlate to the ocular irritation response. Attempts to quantitatively determine the DOI in alternative tests have been limited to ex vivo animal eyes by fluorescent staining for biomarkers of cell death and viability in histological cross sections. It was the purpose of this study to assess whether DOI could also be measured by means of cell viability detected by the MTT assay using 3-dimensional (3D) reconstructed models of cornea and conjunctiva. The formazan-free area of metabolically inactive cells in the tissue after topical substance application is used as the visible correlate of the DOI. Areas of metabolically active or inactive cells are quantitatively analyzed on cryosection images with ImageJ software analysis tools. By incorporating the total tissue thickness, the relative MTT-DOI (rMTT-DOI) was calculated. Using the rMTT-DOI and human reconstructed cornea equivalents, we developed a prediction model based on suitable viability cut-off values. We tested 25 chemicals that cover the whole range of eye irritation potential based on the globally harmonized system of classification and labelling of chemicals (GHS). Principally, the MTT-DOI test method allows distinguishing between the cytotoxic effects of the different chemicals in accordance with all 3 GHS categories for eye irritation. Although the prediction model is slightly over-predictive with respect to non-irritants, it promises to be highly valuable to discriminate between severe irritants (Cat. 1), and mild to moderate irritants (Cat. 2). We also tested 3D conjunctiva models with the aim to specifically address conjunctiva-damaging substances. Using the MTT-DOI method in this model delivers comparable results as the cornea model, but does not add additional information. However, the MTT-DOI method using reconstructed cornea models already provided good predictability that was superior to the already existing established in vitro/ex vivo methods. PMID:25494045
NASA Astrophysics Data System (ADS)
Cassola, V. F.; de Melo Lima, V. J.; Kramer, R.; Khoury, H. J.
2010-01-01
Among computational models, voxel phantoms based on computer tomographic (CT), nuclear magnetic resonance (NMR) or colour photographic images of patients, volunteers or cadavers have become popular in recent years. Although being true to nature representations of scanned individuals, voxel phantoms have limitations, especially when walled organs have to be segmented or when volumes of organs or body tissues, like adipose, have to be changed. Additionally, the scanning of patients or volunteers is usually made in supine position, which causes a shift of internal organs towards the ribcage, a compression of the lungs and a reduction of the sagittal diameter especially in the abdominal region compared to the regular anatomy of a person in the upright position, which in turn can influence organ and tissue absorbed or equivalent dose estimates. This study applies tools developed recently in the areas of computer graphics and animated films to the creation and modelling of 3D human organs, tissues, skeletons and bodies based on polygon mesh surfaces. Female and male adult human phantoms, called FASH (Female Adult meSH) and MASH (Male Adult meSH), have been designed using software, such as MakeHuman, Blender, Binvox and ImageJ, based on anatomical atlases, observing at the same time organ masses recommended by the International Commission on Radiological Protection for the male and female reference adult in report no 89. 113 organs, bones and tissues have been modelled in the FASH and the MASH phantoms representing locations for adults in standing posture. Most organ and tissue masses of the voxelized versions agree with corresponding data from ICRP89 within a margin of 2.6%. Comparison with the mesh-based male RPI_AM and female RPI_AF phantoms shows differences with respect to the material used, to the software and concepts applied, and to the anatomies created.
Giaretta, Elisa; Munerato, Mauro; Yeste, Marc; Galeati, Giovanna; Spinaci, Marcella; Tamanini, Carlo; Mari, Gaetano; Bucci, Diego
2017-01-01
Setting an open-access computer assisted sperm analysis (CASA) may benefit the evaluation of motility in mammalian sperm, especially when economic constraints do not allow the use of a commercial system. There have been successful attempts to develop such a device in Zebra fish sperm and the system has been used in very few studies on mammalian spermatozoa. Against this background, the present study aimed at developing an open-access CASA system for mammalian sperm using the horse as a model and based upon the Image J software previously established for Zebra fish sperm. Along with determining the sperm progressive motility and other kinetic parameters (such as amplitude of lateral head displacement), the "results" window was adjusted to simplify subsequent statistical analyses. The path window was enriched with colored sperm trajectories on the basis of the subpopulation they belong to and a number that allowed the sperm track to be associated to the sperm motility data shown in the "results" window. Data obtained from the novel plugin (named as CASA_bgm) were compared with those of the commercial CASA Hamilton-Thorn IVOS Vers.12, through Bland Altman's plots. While the percentage of total and progressive motile sperm, VCL, VAP, VSL, LIN and STR and ALH were in agreement with those obtained with the commercial system, BCF significantly differed between the two systems probably due to their settings. Interestingly, a positive and significant correlation between the percentages of total motile sperm evaluated through CASA_bgm and those showing high mitochondrial membrane potential evaluated by JC-1 staining was found. In conclusion, CASA_bgm ImageJ plugin could be useful and reliable for stallion sperm motility analysis and it is our aim to apply this system to other mammalian species. Copyright © 2016 Elsevier B.V. All rights reserved.
Baudin, Marine; Cinquin, Bertrand; Sclavi, Bianca; Pareau, Dominique; Lopes, Filipa
2017-09-01
Confocal laser scanning microscopy (CLSM) is one of the most relevant technologies for studying biofilms in situ. Several tools have been developed to investigate and quantify the architecture of biofilms. However, an approach to quantify correctly the evolution of intensity of a fluorescent signal as a function of the structural parameters of a biofilm is still lacking. Here we present a tool developed in the ImageJ open source software that can be used to extract both structural and fluorescence intensity from CLSM data: BIAM (Biofilm Intensity and Architecture Measurement). This is of utmost significance when studying the fundamental mechanisms of biofilm growth, differentiation and development or when aiming to understand the effect of external molecules on biofilm phenotypes. In order to provide an example of the potential of such a tool in this study we focused on biofilm dispersion. cis-2-Decenoic acid (CDA) is a molecule known to induce biofilm dispersion of multiple bacterial species. The mechanisms by which CDA induces dispersion are still poorly understood. To investigate the effects of CDA on biofilms, we used a reporter strain of Escherichia coli (E. coli) that expresses the GFPmut2 protein under control of the rrnBP1 promoter. Experiments were done in flow cells and image acquisition was made with CLSM. Analysis carried out using the new tool, BIAM, indicates that CDA affects the fluorescence intensity of the biofilm structures as well as biofilm architectures. Indeed, our results demonstrate that CDA removes more than 35% of biofilm biovolume and suggest that it results in an increase of the biofilm's mean fluorescence intensity (MFI) by more than 26% compared to the control biofilm in the absence of CDA. Copyright © 2017. Published by Elsevier B.V.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dumas, Michael, E-mail: mdumas1127@gmail.com; Rakowski, Joseph T.
Purpose: To measure sensitivity and stability of the Presage dosimeter in sheet form for various chemical concentrations over a range of clinical photon energies and examine its use for stereotactic body radiation therapy (SBRT) and stereotactic radiosurgery (SRS) QA. Methods: Presage polymer dosimeters were formulated to investigate and optimize their sensitivity and stability. The dosimeter is composed of clear polyurethane base, leucomalachite green (LMG) reporting dye, and bromoform radical initiator in 0.9–1.0 mm thick sheets. The chemicals are mixed together for 2 min, cast in an aluminum mold, and left to cure at 60 psi for a minimum of twomore » days. Dosimeter response was characterized at energies Co-60, 6 MV, 10 MV flattening-filter free, 15 MV, 50 kVp (mean 19.2 keV), and Ir-192. The dosimeters were scanned by a Microtek Scanmaker i800 at 300 dpi, 2{sup 16} bit depth per color channel. Red component images were analyzed with ImageJ and RIT. SBRT QA was done with gamma analysis tolerances of 2% and 2 mm DTA. Results: The sensitivity of the Presage dosimeter increased with increasing concentration of bromoform. Addition of tin catalyst decreased curing time and had negligible effect on sensitivity. LMG concentration should be at least as high as the bromoform, with ideal concentration being 2% wt. Gamma Knife SRS QA measurements of relative output and profile widths were within 2% of manufacturer’s values validated at commissioning, except the 4 mm collimator relative output which was within 3%. The gamma pass rate of Presage with SBRT was 73.7%, compared to 93.1% for EBT2 Gafchromic film. Conclusions: The Presage dosimeter in sheet form was capable of detecting radiation over all tested photon energies and chemical concentrations. The best sensitivity and photostability of the dosimeter were achieved with 2.5% wt. LMG and 8.2% wt. bromoform. Scanner used should not emit any UV radiation as it will expose the dosimeter, as with the Epson 10000 XL scanner. Presage dosimeter in this form was sensitive enough for use in SRS and SBRT QA. The lower gamma pass rate for Presage compared to Gafchromic film can be attributed to the simple equipment used in the fabrication process, which limited the dosimeter’s sensitivity uniformity by agglomeration of air bubbles in the material, nonuniform concentration of chemicals throughout the material, and thickness variations. This demands improvements in mixing tools and molds.« less
Cadle, Brian A; Rasmus, Kristin C; Varela, Juan A; Leverich, Leah S; O'Neill, Casey E; Bachtell, Ryan K; Cooper, Donald C
2010-01-01
Here we describe the first report of using low-cost cellular or web-based digital cameras to image and quantify standardized rapid immunoassay strips as a new point-of-care diagnostic and forensics tool with health applications. Quantitative ratiometric pixel density analysis (QRPDA) is an automated method requiring end-users to utilize inexpensive (∼ $1 USD/each) immunotest strips, a commonly available web or mobile phone camera or scanner, and internet or cellular service. A model is described whereby a central computer server and freely available IMAGEJ image analysis software records and analyzes the incoming image data with time-stamp and geo-tag information and performs the QRPDA using custom JAVA based macros (http://www.neurocloud.org). To demonstrate QRPDA we developed a standardized method using rapid immunotest strips directed against cocaine and its major metabolite, benzoylecgonine. Images from standardized samples were acquired using several devices, including a mobile phone camera, web cam, and scanner. We performed image analysis of three brands of commercially available dye-conjugated anti-cocaine/benzoylecgonine (COC/BE) antibody test strips in response to three different series of cocaine concentrations ranging from 0.1 to 300 ng/ml and BE concentrations ranging from 0.003 to 0.1 ng/ml. This data was then used to create standard curves to allow quantification of COC/BE in biological samples. Across all devices, QRPDA quantification of COC and BE proved to be a sensitive, economical, and faster alternative to more costly methods, such as gas chromatography-mass spectrometry, tandem mass spectrometry, or high pressure liquid chromatography. The limit of detection was determined to be between 0.1 and 5 ng/ml. To simulate conditions in the field, QRPDA was found to be robust under a variety of image acquisition and testing conditions that varied temperature, lighting, resolution, magnification and concentrations of biological fluid in a sample. To determine the effectiveness of the QRPDA method for quantifying cocaine in biological samples, mice were injected with a sub-locomotor activating dose of cocaine (5 mg/kg; i.p.) and were found to have detectable levels of COC/BE in their urine (160.6 ng/ml) and blood plasma (8.1 ng/ml) after 15-30 minutes. By comparison rats self-administering cocaine in a 4 hour session obtained a final BE blood plasma level of 910 ng/ml with an average of 62.5 infusions. It is concluded that automated QRPDA is a low-cost, rapid and highly sensitive method for the detection of COC/BE with health, forensics, and bioinformatics application and the potential to be used with other rapid immunotest strips directed at several other targets. Thus, this report serves as a general reference and method describing the use of image analysis of lateral flow rapid test strips.
In Vivo Efficacy of Histatin-1 in a Rabbit Animal Model.
Oydanich, Marko K; Epstein, Seth P; Gadaria-Rathod, Neha; Guers, John J; Fernandez, Karen B; Asbell, Penny A
2018-06-26
Purpose/Aim: Corneal abrasions and non-healing corneal epithelial defects are common conditions that cause pain and sometimes are slow to heal. Histatins, a family of histidine-rich peptides, have been implicated in oral and skin epithelial wound healing, and have been shown to be effective in vitro in human corneal epithelial cells. The objective of this study was to test the efficacy of histatin-1 on corneal epithelial wound healing in rabbits. Twenty two (22) rabbits were separated into 4 treatment groups, each containing 3-7 rabbits. Treatments included three histatin-1 formulations (0.1ug/ml. 1ug/ml, and 10ug/ml) and one inactive vehicle, one drop given 3 times per day. Eight (8) mm circular wounds were created using 0.5ml of 20% ethyl alcohol in the right eye of each rabbit. A masked observer photographed each eye twice daily using slit-lamp biomicrophotography. Wound area was analyzed by using ImageJ. Statistical analysis was conducted using Graphpad Prism. Wound recovery was faster in animals given 0.1ug/ml, 1ug/ml, and 10ug/ml when compared to the vehicle solution at 6, 24, and 30 hours after wound creation (p < 0.01). No adverse events were observed in any eyes. When analyzing area under the curve, % recovered area was higher overall in the 0.1ug/ml (p < 0.01), 1ug/ml (p < 0.01), and 10ug/ml (p < 0.001) groups when compared to the vehicle solution. Hourly healing rate was also observed to be faster in the 0.1ug/ml, 1ug/ml, and 10ug/ml groups (p < 0.001) at 24 hours post-injury suggesting an accelerated healing process as compared to the vehicle group. This study represents the first in vivo experiment evaluating and confirming the efficacy of topical histatin on the corneal epithelium wound healing. Further studiesare warranted to better understand the mechanism and safety of topical histatin-1 in corneal epithelial wound-healing and its potential role for human disease treatment.
Prediction of bedload sediment transport for heterogeneous sediments in shape
NASA Astrophysics Data System (ADS)
Durafour, Marine; Jarno, Armelle; Le Bot, Sophie; Lafite, Robert; Marin, François
2015-04-01
Key words: Particle shape, in-situ measurements, bedload transport, heterogeneous sediments Bedload sediment transport in the coastal area is a dynamic process mainly influenced by the type of hydrodynamic forcings involved (current and/or waves), the flow properties (velocity, viscosity, depth) and sediment heterogeneity (particle size, density, shape). Although particle shape is recognized to be a significant factor in the hydrodynamic behavior of grains, this parameter is not currently implemented in bedload transport formulations: firstly because the mechanisms of initiation of motion according to particle shape are still not fully understood, and secondly due to the difficulties in defining common shape parameters. In March 2011, a large panel of in-situ instruments was deployed on two sites in the Eastern English Channel, during the sea campaign MESFLUX11. Samples of the sediment cover available for transport are collected, during a slack period, per 2cm thick strata by divers and by using a Shipeck grab. Bedload discharges along a tidal cycle are also collected with a Delft Nile Sampler (DNS; Gaweesh and Van Rijn, 1992, 1994) on both sites. The first one is characterized by a sandy bed with a low size dispersion, while the other study area implies graded sediments from fine sands to granules. A detailed analysis of the data is performed to follow the evolution of in-situ bedload fluxes on the seabed for a single current. In-situ measurements are compared to existing formulations according to a single fraction approach, using the median diameter of the mixture, and a fractionwise approach, involving a discretization of the grading curve. Results emphasize the interest to oscillate between these two methods according to the dispersion in size of the site considered. The need to apply a hiding/exposure coefficient (Egiazaroff, 1965) and a hindrance factor (Kleinhans and Van Rijn, 2002) for size heterogeneous sediments is also clearly highlighted. A really good agreement is found for the non-uniform site between measured fluxes and predictions given by the Wu et al. (2000) model. However, some discrepancies still remain, especially for granules. Hundreds of pictures of grains composing the sediment cover and the bedload discharges are performed. Particle shapes are statistically characterized by three 2D coefficients (circularity, roundness and elongation) after an image processing with the ImageJ software. Present results show a preferential transport of the most circular sediment particles available for transport and reveal that the consideration of particle shape, through the integration of the circularity index in formulations, enhanced the estimations of bedload rates. A new adjustment of the Wu et al. (2000) formula is proposed, which improves significantly the model predictions, especially for granules. Durafour M, Jarno A, Le Bot S, Lafite R, Marin F (2014) Bedload transport for heterogeneous sediments. Environmental Fluid Mechanics. doi: 10.1007/s10652-014-9380-1
Panos, Joseph A.; Hoffman, Joshua T.; Wordeman, Samuel C.; Hewett, Timothy E.
2016-01-01
Background Correction of neuromuscular impairments after anterior cruciate ligament injury is vital to successful return to sport. Frontal plane knee control during landing is a common measure of lower-extremity neuromuscular control and asymmetries in neuromuscular control of the knee can predispose injured athletes to additional injury and associated morbidities. Therefore, this study investigated the effects of anterior cruciate ligament injury on knee biomechanics during landing. Methods Two-dimensional frontal plane video of single leg drop, cross over drop, and drop vertical jump dynamic movement trials was analyzed for twenty injured and reconstructed athletes. The position of the knee joint center was tracked in ImageJ software for 500 milliseconds after landing to calculate medio-lateral knee motion velocities and determine normal fluency, the number of times per second knee velocity changed direction. The inverse of this calculation, analytical fluency, was used to associate larger numerical values with fluent movement. Findings Analytical fluency was decreased in involved limbs for single leg drop trials (P=0.0018). Importantly, analytical fluency for single leg drop differed compared to cross over drop trials for involved (P<0.001), but not uninvolved limbs (P=0.5029). For involved limbs, analytical fluency values exhibited a stepwise trend in relative magnitudes. Interpretation Decreased analytical fluency in involved limbs is consistent with previous studies. Fluency asymmetries observed during single leg drop tasks may be indicative of abhorrent landing strategies in the involved limb. Analytical fluency differences in unilateral tasks for injured limbs may represent neuromuscular impairment as a result of injury. PMID:26895446
Yeoh, S; Church, M; Lackie, P; McGill, J; Mota, M; Hossain, P
2011-09-01
Aeroallergen exposure to the conjunctival epithelium in seasonal allergic conjunctivitis (SAC) may induce a cellular stress response that disrupts the barrier properties of the conjunctival epithelium, resulting in allergic disease. Whether such changes occur in SAC is unknown. Epithelial permeability is known to be increased when protease activated receptor 2 (PAR-2) is activated. We evaluated the expression of PAR-2 in patients with SAC-in-season (SACS) and compared it with control non-atopic subjects or those with out-of-season allergic conjunctivitis (OSAC). Six SACS, eight normal and four OSAC specimens were examined immunohistochemically for PAR-2 and quantified in a masked fashion for the percentage of epithelia stained for each marker using Image-J software. Conjunctival epithelial heights were measured in all groups to confirm the presence of allergic eye disease. Mean percentage staining of PAR-2 was significantly greater in SACS that in normal specimens (73.4 ± 15.4% vs 32.8 ± 30.0%, p=0.038) or in OSAC (73.4 ± 15.4% vs 1.4 ± 2.2%, p=0.01). Mean conjunctival epithelial height was significantly raised in SACS (63.8 ± 9.0 μm) versus controls (44.7 ± 11.2 μm) (p=0.003, unpaired t test). Conjunctival epithelial PAR-2 is significantly upregulated in SAC. This supports the view that disruption of the barrier properties of the conjunctival epithelium is an important event in SAC pathogenesis.
Strampe, Margaret R; Huckenpahler, Alison L; Higgins, Brian P; Tarima, Sergey; Visotcky, Alexis; Stepien, Kimberly E; Kay, Christine N; Carroll, Joseph
2018-05-01
To examine repeatability and reproducibility of ellipsoid zone (EZ) width measurements in patients with retinitis pigmentosa (RP) using a longitudinal reflectivity profile (LRP) analysis. We examined Bioptigen optical coherence tomography (OCT) scans from 48 subjects with RP or Usher syndrome. Nominal scan lengths were 6, 7, or 10 mm, and the lateral scale of each scan was calculated using axial length measurements. LRPs were generated from OCT line scans, and the peak corresponding to EZ was manually identified using ImageJ. The locations at which the EZ peak disappeared were used to calculate EZ width. Each scan was analyzed twice by each of two observers, who were masked to their previous measurements and those of the other observer. On average, horizontal width (HW) was significantly greater than vertical width (VW), and there was high interocular symmetry for both HW and VW. We observed excellent intraobserver repeatability with intraclass correlation coefficients (ICCs) ranging from 0.996 to 0.998 for HW and VW measurements. Interobserver reproducibility was also excellent for both HW (ICC = 0.989; 95% confidence interval [CI] = 0.983-0.995) and VW (ICC = 0.991; 95% CI = 0.985-0.996), with no significant bias observed between observers. EZ width can be measured using LRPs with excellent repeatability and reproducibility. Our observation of greater HW than VW is consistent with previous observations in RP, though the reason for this anisotropy remains unclear. We describe repeatability and reproducibility of a method for measuring EZ width in patients with RP or Usher syndrome. This approach could facilitate measurement of retinal band thickness and/or intensity.
Worthen, Wade B.
2016-01-01
Some adult odonates resist parasitism by larval water mites (Arrenurus spp.) with melanotic encapsulation, in which the mite’s stylestome is clogged and the mite starves. In summer 2014, we counted the engorged and resisted mites on 2,729 adult odonates sampled by aerial net at 11 water bodies in Greenville Co. and Pickens Co., SC, and tested the hypothesis that the frequency and intensity of resistance correlates with parasite prevalence (the percentage of parasitized hosts). Resistance prevalence (the percentage of parasitized hosts that resisted at least one mite) varied significantly among host species, exceeding 60% for Argia fumipennis (Burmeister) and Celithemis fasciata Kirby but less than 20% for other species. However, neither resistance prevalence nor mean resistance intensity (mean percentage of resisted mites on resisting hosts) correlated with parasite prevalence. We described potential effects of parasitism on host development of A. fumipennis and Pachydiplax longipennis (Burmeister) by comparing the percent asymmetry of forewing lengths between parasitized and unparasitized individuals. There was no significant difference in asymmetry for either males or females of A. fumipennis, or males of Pa. longipennis (females were not sampled). We also evaluated differences in melanotic encapsulation between A. fumipennis, which readily encapsulates mites in nature, and Pa. longipennis. We inserted a 2.0-mm piece of sterile monofilament line into the thorax of captured individuals for 24 h and compared mean gray value scores of inserted and emergent ends using Image-J software. There was no difference in melanotic encapsulation between species. PMID:27067302
Frontal facial proportions of 12-year-old southern Chinese: a photogrammetric study.
Yeung, Charles Yat Cheong; McGrath, Colman Patrick; Wong, Ricky Wing Kit; Hägg, Erik Urban Oskar; Lo, John; Yang, Yanqi
2015-08-14
This study aimed to establish norm values for facial proportion indices among 12-year-old southern Chinese children, to determine lower facial proportion, and to identify gender differences in facial proportions.A random population sample of 514 children was recruited. Fifteen facial landmarks were plotted with ImageJ (V1.45) on standardized photos and 22 Facial proportion index values were obtained. Gender differences were analyzed by 2-sample t-test with 95% confidence interval. Repeated measurements were conducted on approximately 10% of the cases.The rate of adopted subjects was 52.5% (270/514). Intraclass correlation coefficient values (ICC) for intra- examiner reliability were >0.87. Population facial proportion index values were derived. Gender differences in 11 of the facial proportion indices were evident (P < 0.05).Upper face-face height (N- Sto/ N- Gn), vermilion height (Ls-Sto/Sto-Li), upper face height-biocular width (N-Sto/ExR-ExL) and nose -face height (N-Sn/N-Gn) indices were found to be larger among girls (P < 0.01). Males had larger lower face-face height (Sn -Gn/ N-Gn), mandibulo-face height (Sto-Gn/N-Gn), mandibulo-upper face height (Sto-Gn/N-Sto), nasal (AlR-AlL/N-Sn), upper lip height-mouth width (Sn-Sto/ChR-ChL), upper lip-upper face height (Sn-Sto/N-Sto) and upper lip-nose height (Sn-Sto/N-Sn) indices (P < 0.05).Population norm of facial proportion indices for 12-year-old Southern Chinese were derived and mean lower facial proportion were obtained. Sexual dimorphism is apparent.
Choroid Sprouting Assay: An Ex Vivo Model of Microvascular Angiogenesis
Shao, Zhuo; Friedlander, Mollie; Hurst, Christian G.; Cui, Zhenghao; Pei, Dorothy T.; Evans, Lucy P.; Juan, Aimee M.; Tahir, Houda; Duhamel, François; Chen, Jing; Sapieha, Przemyslaw; Chemtob, Sylvain; Joyal, Jean-Sébastien; Smith, Lois E. H.
2013-01-01
Angiogenesis of the microvasculature is central to the etiology of many diseases including proliferative retinopathy, age-related macular degeneration and cancer. A mouse model of microvascular angiogenesis would be very valuable and enable access to a wide range of genetically manipulated tissues that closely approximate small blood vessel growth in vivo. Vascular endothelial cells cultured in vitro are widely used, however, isolating pure vascular murine endothelial cells is technically challenging. A microvascular mouse explant model that is robust, quantitative and can be reproduced without difficulty would overcome these limitations. Here we characterized and optimized for reproducibility an organotypic microvascular angiogenesis mouse and rat model from the choroid, a microvascular bed in the posterior of eye. The choroidal tissues from C57BL/6J and 129S6/SvEvTac mice and Sprague Dawley rats were isolated and incubated in Matrigel. Vascular sprouting was comparable between choroid samples obtained from different animals of the same genetic background. The sprouting area, normalized to controls, was highly reproducible between independent experiments. We developed a semi-automated macro in ImageJ software to allow for more efficient quantification of sprouting area. Isolated choroid explants responded to manipulation of the external environment while maintaining the local interactions of endothelial cells with neighboring cells, including pericytes and macrophages as evidenced by immunohistochemistry and fluorescence-activated cell sorting (FACS) analysis. This reproducible ex vivo angiogenesis assay can be used to evaluate angiogenic potential of pharmacologic compounds on microvessels and can take advantage of genetically manipulated mouse tissue for microvascular disease research. PMID:23922736
2014-01-01
Background Malaria in pregnancy remains a major health problem. Placental malaria infection may cause pathophysiological changes in pregnancy and result in morphological changes to placental villi. Quantitative histomorphological image analysis of placental biopsies was performed to compare placental villous architecture between active or treated placental malaria cases and controls. Methods A total of 67 placentas were studied from three clinical groups: control patients who did not have malaria (n = 27), active (n = 14) and treated (n=26) malaria cases, including both Plasmodium falciparum and Plasmodium vivax infections. Image analysis of histological placental sections was performed using ImageJ software to measure the number and size (area) of terminal villi, perimeter measurement per villus and total perimeter per unit area, and number of capillaries per villus (vascularity). Histological features of placental malaria were scored and these results were correlated with malaria status and clinical outcomes. Results Villous size correlated with vascularity (p <0.0001) but was inversely correlated with observed villi per unit area, (p = 0.0001). Significantly greater villous area and vascularity was observed in UK controls. Indices of histological malaria infection were significantly greater in active versus treated malaria cases. Active placental malaria cases showed significantly smaller villous area (p <0.0084), vascularity (p <0.0139) and perimeter (p <0.0006) than treated malaria cases or controls, but significantly more villi per unit area (p <0.0001). Villous size in treated malaria cases was significantly larger than active placental malaria cases (p <0.001) and similar to controls. There was a significant relationship between villous number and anaemia at the time of infection (p <0.0034), but not placental weight, birth weight or gestational age at delivery. No differences were found between histology or villous morphology comparing infections with P. falciparum or P. vivax. Conclusions These results imply that villous size, perimeter and vascularity are acutely decreased during active placental malaria, decreasing the surface area available for gas exchange per villus. However the increased number of villi per unit area offsets this change and persists after treatment. Histopathological and villous architectural changes may be reversed by early detection and appropriate anti-malarial treatment. PMID:24386908
Pritchard, J.M.; Papaioannou, A.; Tomowich, C.; Giangregorio, L.M.; Atkinson, S.A.; Beattie, K.A.; Adachi, J.D.; DeBeer, J.; Winemaker, M.; Avram, V.; Schwarcz, H.P.
2016-01-01
Purpose The purpose of this study was to determine whether trabecular bone mineralization differed in adults with type 2 diabetes compared to adults without type 2 diabetes. Methods Proximal femur specimens were obtained following a total hip replacement procedure from men and women ≥65 years of age with and without type 2 diabetes. A scanning electron microscope was used for quantitative backscattered electron imaging (qBEI) analysis of trabecular bone samples from the femoral neck. Gray scale images (pixel size=5.6 μm2) were uploaded to ImageJ software and gray level (GL) values were converted to calcium concentrations (weight [wt] % calcium [Ca]) using data obtained with energy dispersive X-ray spectrometry. The following bone mineralization density distribution (BMDD) outcomes were collected: the weighted mean bone calcium concentration (CaMEAN), the most frequently occurring bone calcium concentration (CaPEAK) and mineralization heterogeneity (CaWIDTH). Differences between groups were assessed using the Student’s t-test for normally distributed data and Mann–Whitney U-test for non-normally distributed data. An alpha value of <0.05 was considered significant. Results Thirty-five Caucasian participants were recruited (mean [standard deviation, SD] age, 75.5 [6.5] years): 14 adults with type 2 diabetes (years since type 2 diabetes diagnosis, 13.5 [7.4] years) and 21 adults without type 2 diabetes. In the adults with type 2 diabetes, bone CaMEAN was 4.9% greater (20.36 [0.98] wt.% Ca versus 19.40 [1.07] wt.% Ca, p=0.015) and CaWIDTH was 9.4% lower (median [interquartile range] 3.55 [2.99–4.12] wt.% Ca versus 3.95 [0.71] wt.% Ca, p<0.001) compared to controls. There was no between-group difference in CaPEAK (21.12 [0.97] wt.% Ca for type 2 diabetes versus 20.44 [1.30] wt.% Ca for controls, p=0.121). Conclusion The combination of elevated mean calcium concentration in bone and lower mineralization heterogeneity in adults with type 2 diabetes may have deleterious effects on the biomechanical properties of bone. These microscopic alterations in bone mineralization, which may be mediated by suppressed bone remodeling, further elucidate higher fracture risk in adults with type 2 diabetes. PMID:23356988
Automated grading system for evaluation of ocular redness associated with dry eye.
Rodriguez, John D; Johnston, Patrick R; Ousler, George W; Smith, Lisa M; Abelson, Mark B
2013-01-01
We have observed that dry eye redness is characterized by a prominence of fine horizontal conjunctival vessels in the exposed ocular surface of the interpalpebral fissure, and have incorporated this feature into the grading of redness in clinical studies of dry eye. To develop an automated method of grading dry eye-associated ocular redness in order to expand on the clinical grading system currently used. Ninety nine images from 26 dry eye subjects were evaluated by five graders using a 0-4 (in 0.5 increments) dry eye redness (Ora Calibra™ Dry Eye Redness Scale [OCDER]) scale. For the automated method, the Opencv computer vision library was used to develop software for calculating redness and horizontal conjunctival vessels (noted as "horizontality"). From original photograph, the region of interest (ROI) was selected manually using the open source ImageJ software. Total average redness intensity (Com-Red) was calculated as a single channel 8-bit image as R - 0.83G - 0.17B, where R, G and B were the respective intensities of the red, green and blue channels. The location of vessels was detected by normalizing the blue channel and selecting pixels with an intensity of less than 97% of the mean. The horizontal component (Com-Hor) was calculated by the first order Sobel derivative in the vertical direction and the score was calculated as the average blue channel image intensity of this vertical derivative. Pearson correlation coefficients, accuracy and concordance correlation coefficients (CCC) were calculated after regression and standardized regression of the dataset. The agreement (both Pearson's and CCC) among investigators using the OCDER scale was 0.67, while the agreement of investigator to computer was 0.76. A multiple regression using both redness and horizontality improved the agreement CCC from 0.66 and 0.69 to 0.76, demonstrating the contribution of vessel geometry to the overall grade. Computer analysis of a given image has 100% repeatability and zero variability from session to session. This objective means of grading ocular redness in a unified fashion has potential significance as a new clinical endpoint. In comparisons between computer and investigator, computer grading proved to be more reliable than another investigator using the OCDER scale. The best fitting model based on the present sample, and usable for future studies, was [Formula: see text] is the predicted investigator grade, and [Formula: see text] and [Formula: see text] are logarithmic transformations of the computer calculated parameters COM-Hor and COM-Red. Considering the superior repeatability, computer automated grading might be preferable to investigator grading in multicentered dry eye studies in which the subtle differences in redness incurred by treatment have been historically difficult to define.
Relationship between echotextural and histomorphometric characteristics of stallion testes.
Pozor, Malgorzata; Morrissey, Heather; Albanese, Valeria; Khouzam, Natalie; Deriberprey, Alexis; Macpherson, Margo L; Kelleman, Audrey A
2017-09-01
The goal of this study was to investigate correlations between objective measures of testicular echotexture and histomorphometric attributes related to the histological composition of stallion testes. Fifty-four scrotal testes were obtained from three groups of stallions during routine castrations: colts <1 yr old (n = 18), young stallions 1-5 yrs old (n = 27), mature stallions > 5 yrs old (n = 9). In addition, two scrotal testes with degeneration, 16 retained inguinal and 10 retained abdominal testes were surgically obtained. Cross-sectional and longitudinal ultrasonograms were obtained for each testis. Mean numerical pixel values (NPVs) as well as pixel standard deviations (PSDs) were determined for each image (ImageJ-1.5 software). Histomorphometric attributes of the seminiferous tubules (STs) were derived (three tissue samples per each testis) using image analysis software [relative STs area: RSTA = ST area/total cross-sectional area (TA) x 100%; relative STs lumen: RSTL = ST lumen area/TA x 100%; individual ST area; ISTA; individual ST lumen: ISTL; seminiferous epithelium height: SHE]. Degree of fibrosis was graded semi-quantitatively (0-3) in samples from 17 testes. All measures of testicular echotexture as well as all histomorphometric attributes of STs had highest values when obtained from the scrotal testes of young and mature stallions (P < 0.05). The NPVs and PSDs from the ultrasonographic images of the scrotal testes were significantly correlated with all histomorphometric attributes of STs (P < 0.001). However, there was no correlation between the majority of these measures and attributes if each group of the scrotal testes was analyzed separately. The NPVs from the ultrasonographic images of the retained inguinal testes were correlated with RSTA, RSTL, ISTA, and ISTL, while the NPVs from the retained abdominal testes were not correlated with any of the histomorphometric attributes of the STs. Testes with high degree of fibrosis had variable values of pixel intensity and pixel heterogeneity. Based on the results of this study, we concluded that the pixel intensity and pixel heterogeneity of stallion testes increase during the first year of life and remain stable in young and mature stallions. These changes occur in parallel to the development of the seminiferous tubules. Testicular echogenicity in stallions does not seem to reflect degree of testicular fibrosis. Retained abdominal testes have lower and less heterogeneous echogenicity than scrotal testes from stallions that are more than one year old. While pixel analysis cannot replace biopsy in assessing testicular histomorphology in young and mature stallions, testicular echogenicity is a good indicator of peri-pubertal growth and expansion of the seminiferous tubules. Copyright © 2017. Published by Elsevier Inc.
Space use by 4 strains of laying hens to perch, wing flap, dust bathe, stand and lie down.
Riddle, Elizabeth R; Ali, Ahmed B A; Campbell, Dana L M; Siegford, Janice M
2018-01-01
The laying hen industry is implementing aviary systems intended to improve welfare by providing hens with more space and resources to perform species-specific behaviors. To date, limited research has examined spatial requirements of various strains of laying hens for performing key behaviors and none has been conducted within an alternative housing system. This study investigated the amount of space used by 4 strains of laying hens (Hy-Line Brown [HB], Bovans Brown [BB], DeKalb White [DW], and Hy-Line W36) to perform 5 different behaviors in the litter area of a commercial-style aviary. Hens were recorded standing [S], lying [L], perching [P], wing flapping [WF], and dust bathing [DB] on an open-litter area with an outer perch between 12:00 and 15:00 at peak lay (28 wk of age). Still images of each behavior were analyzed using ImageJ software for 16 hens per strain, and maximum hen length and width were used to calculate total area occupied per hen for each behavior. Brown hens required, on average, 89.6cm2 more space for S (P≤0.021) and 81.5cm2 more space for L (P≤0.013) than white hens. White hens used, on average, 572cm2 more space to perform WF than brown hens (P≤0.024) while brown hens used 170.3cm2 more space for DB than white hens (P≤0.022). On average, hens of all strains were wider while perching than the 15cm commonly recommended per hen (e.g., DW: 18.03; HB: 21.89cm), and brown hens required, on average, 3.38cm more space while perching than white hens (P≤0.01). Brown and white hens occupy different amounts of space when performing key behaviors. These differences, along with factors such as behavioral synchrony, clustering, and preferred inter-bird distances associated with these behaviors, should be considered when creating industry guidelines, crafting legislation and designing and stocking laying hen facilities to ensure hens can fulfill their behavioral needs.
Conjunctival UV autofluorescence--prevalence and risk factors.
Wolffsohn, James S; Drew, Tom; Sulley, Anna
2014-12-01
Autofluorescence of ultraviolet (UV) light has been shown to occur in localised areas of the bulbar conjunctiva, which map to active cellular changes due to UV and environmental exposure. This study examined the presence of conjunctival UV autofluorescence in eye care practitioners (ECPs) across Europe and the Middle East and its associated risk factors. Images were captured of 307 ECPs right eyes in the Czech Republic, Germany, Greece, Kuwait, Netherlands, Sweden, Switzerland, United Arab Emirates and the United Kingdom using a Nikon D100 camera and dual flash units through UV filters. UV autofluorescence was outlined using ImageJ software and the nasal and temporal area quantified. Subjects were required to complete a questionnaire on their demographics and lifestyle including general exposure to UV and refractive correction. Average age of the subjects was 38.5±12.2 years (range 19-68) and 39.7% were male. Sixty-two percent of eyes had some conjunctival damage as indicated by UV autofluorescence. The average area of damage was higher (p=0.005) nasally (2.95±4.52mm(2)) than temporally (2.19±4.17mm(2)). The area of UV damage was not related to age (r=0.03, p=0.674), gender (p=0.194), self-reported sun exposure lifestyle (p>0.05), geographical location (p=0174), sunglasses use (p>0.05) or UV-blocking contact lens use (p>0.05), although it was higher in those wearing contact lenses with minimal UV-blocking and no spectacles (p=0.015). The area of UV damage was also less nasally in those who wore contact lenses and spectacles compared to those with no refractive correction use (p=0.011 nasal; p=0.958 temporal). UV conjunctival damage is common even in Europe, Kuwait and UAE, and among ECPs. The area of damage appears to be linked with the use of refractive correction, with greater damage nasally than temporally which may be explained by the peripheral light focusing effect. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Ultrasound therapy applicators for controlled thermal modification of tissue
NASA Astrophysics Data System (ADS)
Burdette, E. Clif; Lichtenstiger, Carol; Rund, Laurie; Keralapura, Mallika; Gossett, Chad; Stahlhut, Randy; Neubauer, Paul; Komadina, Bruce; Williams, Emery; Alix, Chris; Jensen, Tor; Schook, Lawrence; Diederich, Chris J.
2011-03-01
Heat therapy has long been used for treatments in dermatology and sports medicine. The use of laser, RF, microwave, and more recently, ultrasound treatment, for psoriasis, collagen reformation, and skin tightening has gained considerable interest over the past several years. Numerous studies and commercial devices have demonstrated the efficacy of these methods for treatment of skin disorders. Despite these promising results, current systems remain highly dependent on operator skill, and cannot effectively treat effectively because there is little or no control of the size, shape, and depth of the target zone. These limitations make it extremely difficult to obtain consistent treatment results. The purpose of this study was to determine the feasibility for using acoustic energy for controlled dose delivery sufficient to produce collagen modification for the treatment of skin tissue in the dermal and sub-dermal layers. We designed and evaluated a curvilinear focused ultrasound device for treating skin disorders such as psoriasis, stimulation of wound healing, tightening of skin through shrinkage of existing collagen and stimulation of new collagen formation, and skin cancer. Design parameters were examined using acoustic pattern simulations and thermal modeling. Acute studies were performed in 201 freshly-excised samples of young porcine underbelly skin tissue and 56 in-vivo treatment areas in 60- 80 kg pigs. These were treated with ultrasound (9-11MHz) focused in the deep dermis. Dose distribution was analyzed and gross pathology assessed. Tissue shrinkage was measured based on fiducial markers and video image registration and analyzed using NIH Image-J software. Comparisons were made between RF and focused ultrasound for five energy ranges. In each experimental series, therapeutic dose levels (60degC) were attained at 2-5mm depth. Localized collagen changes ranged from 1-3% for RF versus 8-15% for focused ultrasound. Therapeutic ultrasound applied at high frequencies can achieve temperatures and dose distributions which concentrate in a depth profile that coincides with the location of maximum structural collagen content in skin tissues. Using an appropriate transducer configuration produces coverage of significant lateral area, thus making this a practical approach for treatment of skin disorders.
Earthquake Parameters Inferred from the Hoping River Pseudotachylyte, Taiwan
NASA Astrophysics Data System (ADS)
Korren, C.; Ferre, E. C.; Yeh, E. C.; Chou, Y. M.
2014-12-01
Taiwan, one of the most seismically active areas in the world, repeatedly experiences violent earthquakes, such as the 1999 Mw 7.6 Chi-Chi earthquake, in highly populated areas. The main island of Taiwan lies in the convergent tectonic region between the Eurasian Plate and Philippine Sea Plate. Fault pseudotachylytes form by frictional melting along the fault plane during large seismic slip events and therefore constitute earthquake fossils. The width of a pseudotachylyte generation vein is a crude proxy for earthquake magnitude. The attitude of oblique injection veins primarily reflects slip kinematics. Additional constraints on the seismic slip direction and slip sense can be obtained 1) from the principal axes of the magnetic fabric of generation veins and 2) from 3D tomographic analysis of vein geometry. A new pseudotachylyte locality discovered along the Hoping River offers an unparalleled opportunity to learn more about the Plio-Pleistocene paleoseismology and seismic kinematics of northeastern Taiwan. Field work measured the orientations and relations of structural features yields a complex geometry of generation and injection veins. Pseudotachylytes were sampled for tomographic, magnetic fabric and scanning electron microscope analyses. An oriented block of pseudotachylyte was sliced then stitched into a 3-D tomographic model using the Image-J software image stack plug-in. Tomographic analysis shows pseudotachylyte veins originate from a single slip event at sample size. An average vein thickness ranges from 1 mm proximal to areas with abundant injection veins to 2 mm. The displacement calculated after Sibson's 1975 method, displacement equals the square of vein thickness multiplied by 436 yields a range from 4.36 cm to 17.44 cm. The pseudotachylytes displacement typifies earthquakes less than magnitude 5. However, this crude estimate of displacement requires further discussion. Comparison of the calculated displacements by different methodology may further constrain the values. Improving the accuracy of parameters pertaining to depth, pressure and temperature conditions, faulting style and coseismic fluids will vastly affect these displacement values. Aspects of focal mechanism determination leads to a more comprehensive assessment of both prehistoric and modern seismic risk.
Iriuchishima, Takanori; Ryu, Keinosuke; Aizawa, Shin; Fu, Freddie H
2016-01-01
The purpose of this study was to compare the centre position of each anterior cruciate ligament bundle in its femoral footprint in measurements including and excluding the fan-like extension fibres. Fourteen non-paired human cadaver knees were used. All soft tissues around the knee were resected except the ligaments. The ACL was divided into antero-medial (AM) and postero-lateral (PL) bundles according to the difference in tension patterns. The ACL was carefully dissected, and two outlines were made of the periphery of each bundle insertion site: those which included and those which excluded the fan-like extension fibres. An accurate lateral view of the femoral condyle was photographed with a digital camera, and the images were downloaded to a personal computer. The centre position of each bundle, including and excluding the fan-like extension fibres, was measured with ImageJ software (National Institution of Health). Evaluation of the centre position was performed using the modified quadrant method. The centre of the femoral AM bundle including the fan-like extension was located at 28.8% in a shallow-deep direction and 37.2% in a high-low direction. When the AM bundle was evaluated without the fan-like extension, the centre was significantly different at 34.6% in a shallow-deep direction (p = 0.000) and 36% in a high-low direction. The centre of the PL bundle including the fan-like extension was found at 37.1% in a shallow-deep direction and 73.4% in a high-low direction. When the PL bundle was evaluated without the fan-like extension, the centre was significantly different at 42.7% in a shallow-deep direction (p = 0.000) and 69.3% in a high-low direction (p = 0.000). The centre position of the AM and PL bundles in the femoral ACL footprint was significantly different depending on the inclusion or exclusion of the fan-like extension fibres. For the clinical relevance, to reproduce the direct femoral insertion in the anatomical ACL reconstruction, tunnels should be placed relatively shallow and high in the femoral ACL footprint.
Space use by 4 strains of laying hens to perch, wing flap, dust bathe, stand and lie down
Campbell, Dana L. M.
2018-01-01
The laying hen industry is implementing aviary systems intended to improve welfare by providing hens with more space and resources to perform species-specific behaviors. To date, limited research has examined spatial requirements of various strains of laying hens for performing key behaviors and none has been conducted within an alternative housing system. This study investigated the amount of space used by 4 strains of laying hens (Hy-Line Brown [HB], Bovans Brown [BB], DeKalb White [DW], and Hy-Line W36) to perform 5 different behaviors in the litter area of a commercial-style aviary. Hens were recorded standing [S], lying [L], perching [P], wing flapping [WF], and dust bathing [DB] on an open-litter area with an outer perch between 12:00 and 15:00 at peak lay (28 wk of age). Still images of each behavior were analyzed using ImageJ software for 16 hens per strain, and maximum hen length and width were used to calculate total area occupied per hen for each behavior. Brown hens required, on average, 89.6cm2 more space for S (P≤0.021) and 81.5cm2 more space for L (P≤0.013) than white hens. White hens used, on average, 572cm2 more space to perform WF than brown hens (P≤0.024) while brown hens used 170.3cm2 more space for DB than white hens (P≤0.022). On average, hens of all strains were wider while perching than the 15cm commonly recommended per hen (e.g., DW: 18.03; HB: 21.89cm), and brown hens required, on average, 3.38cm more space while perching than white hens (P≤0.01). Brown and white hens occupy different amounts of space when performing key behaviors. These differences, along with factors such as behavioral synchrony, clustering, and preferred inter-bird distances associated with these behaviors, should be considered when creating industry guidelines, crafting legislation and designing and stocking laying hen facilities to ensure hens can fulfill their behavioral needs. PMID:29304059
Salix polaris growth responses to active layer detachment and solifluction processes in High Arctic.
NASA Astrophysics Data System (ADS)
Siekacz, Liliana
2015-04-01
The work is dedicated to demonstrate the potential of Salix polaris grow properties in the dendrogemorphologic image, analyzing periglacially induced slope processes in the high Arctic.. Observed anatomical and morphological plants responses to solifluction and active layer detachment processes are presented qualitatively and quantitatively as a summary of presented features frequency. The results are discussed against the background of the other research results in this field. The investigations was performed in Ebba valley, in the vicinity of Petunia Bay, northernmost part of Billefjorden in central Spitsbergen (Svalbard). Environmental conditions are characterized by annual precipitation sum lower than 200 mm (Hagen et al.,1993) and average summer temperature of about 5°C, with maximum daily temperatures rarely exceeding 10°C (Rachlewicz, 2009). Collected shrub material was prepared according to the methods presented by Schweingruber and Poschlod (2005). Thin (approx. 15-20μm) sections of the whole cross-section were prepared with a sledge microtome, stained with Safranine and Astra blue and finally permanently fixed on microslides with Canada balsam and dried. Snapshots were taken partially for each cross-section with digital camera (ColorView III, Olympus) connected to a microscope (Olympus BX41) and merged into one, high resolution image. After all, ring widths were measured in 3-4 radii in every single cross-section using ImageJ software. Analyzed plants revealed extremely harsh environmental conditions of their growth. Buchwał et al. (2013) provided quantitative data concerning missing rings and partially missing rings in shrubs growing on Ebba valley floor. Mean ring width at the level of 79μm represents one of the smallest values of yearly growth ever noted. The share of missing rings and partially missing rings was 11,2% and 13,6% respectively. Plants growing on Ebba valley slope indicate almost twice smaller values of ring width (41μm), and higher participation of missing and partially missing rings. Share of missing rings in shrubs growing within an active layer detachment on the valley slope reached 16,22% and 15,36%. Even higher variation is observed in partially missing rings which account for 31,07% within detachment and 23,39% on surrounding slope. Those values are more than twice higher comparing to the valley floor. There is also noticeable difference between detachment and surrounding slope indicating that wedging rings are an effect of mechanical stress that is higher within the detachment. Comparing growth patterns in aboveground and belowground plant parts different growth allocation is noticed. Years of detachment event growth rings were present only in aboveground parts. It is supposed that mechanical stress delays the onset of the growing season similarly to low temperatures (Buchwał et al., 2013), resulting in not enough time to fully allocate resources for growth in the belowground parts. Growth pattern is extremely irregular, indicating that the slope is in constant movement, which disrupts growth conditions. Analyzed shrubs showed two possible event years: 2006 and 2008, with the highest participation of missing and partially missing rings. Air and ground temperature data were also analyzed and confirmed that active layer detachment happened in 2006. REFERENCES Buchwał A, Rachlewicz G, Fonti P, Cherubini P, Gärtner H, (2013) Temperature modulates intra-plant growth of Salix Polaris from a high Arctic site (Svalbard). Polar Biol 36:1305-1318. Hagen J O, Liestøl O, Roland E, Jørgensen T, (1993) Glacier atlas of Svalbard and Jan Mayen. Norsk Polarinstitutt Meddelelser 129: 160. Rachlewicz G, (2009) Contemporary sediment fluxes and relief changes in high Arctic glacierized valley systems (Billefjorden, Central Spitsbergen). Wyd. Nauk. UAM Poznań, seria Geografia 87:204. Schweingruber FH, Poschlod P, (2005) Growth rings in herbs and shrubs: life span, age determination and stem anatomy. For Snow Landsc Res 79:195-415
Kullage, Smitha; Jose, Maji; Shanbhag, Vagish Kumar L; Abdulla, Riaz
2017-01-01
Detection of oral cancer at an early stage is of utmost importance to decrease morbidity and mortality. Tumor stroma plays a critical role during carcinogenesis. There is lack of information regarding the characteristics of the stroma in relation to the invading malignant epithelial cells and the interdependence between stroma and tumor cells in different grades of oral squamous cell carcinoma (OSCC). The present study was aimed to analyze and compare the nature of stroma in the vicinity of invading tumor islands in different grades of OSCC, using a histochemical technique picrosirius-polarization method. The present study also evaluated and correlated the possible role of inflammatory response in determining the nature of the stroma. The study included thirty cases of different grades of histologically diagnosed OSCC and ten sections of normal buccal mucosa as a control group. Nature of collagen was analyzed using picrosirius-polarization method, and intensity of inflammatory cell infiltrate was recorded using ImageJ software (1.42q, NIH, USA). The results were tabulated and analyzed statistically. Normal oral mucosa showed predominantly reddish birefringence. All cases of well-differentiated OSCC showed reddish-orange color. Nearly 70% moderately differentiated cases showed yellowish-orange (YO) and 60% of poorly differentiated cases, showed greenish-yellow (GY). The mean inflammatory cell count was highest in well-differentiated group. There was shift to YO and GY collagen when the cell differentiation and inflammatory cell count decreased in moderate and poorly differentiated cases. Both inflammatory cells and tumor cells have a role in determining the nature of the collagen fibers in tumor stroma of OSCC, probably with opposing effects on stromal behavior and hence both are significant in predicting prognosis.
Should conventional angiography be the gold standard for carotid stenosis?
Zhang, Wayne W; Harris, Linda M; Dryjski, Maciej L
2006-12-01
To compare conventional angiography (CA) and rotational angiography (RA) to assess the degree of angiographically-measured stenosis versus cross-sectional area (CSA) stenosis in an in vitro carotid model. Various grades of stenosis were created by adhering different amounts of silicone rubber sealant onto the inner wall of clear, radiolucent tubes. Following 2- and 3-projection CA and 20-projection RA, the tubes were transected at the actual maximum stenosis. The cross-sectional areas were digitally photographed, and CSA stenosis was calculated using ImageJ planimeter software. The differences among CA, RA, and CSA stenosis measurements were compared statistically. There was no significant difference between RA and CSA stenosis measurements (p=0.46). Conventional angiography with 2 or 3 projections between 0 degrees and 90 degrees underestimated the severity of disease in 19 (63%) of 30 samples. The maximum stenosis percentage was significantly lower in CA versus RA (p<0.0001 in 2-projection, p<0.0003 in 3-projection) and in CA versus CSA stenosis (p<0.0004 in 2-projection, p<0.001 in 3-projection). The maximum stenosis percentages measured by RA were less than CSA stenosis in 5 (71.4%) of 7 tubes (p=NS) containing 50% to 69% stenoses. Eight tubes had mountain-shaped lesions, which was significantly overestimated by RA (11.5%+/-9.7%, p<0.012). CA with 2 or 3 projections significantly underestimates the maximum stenosis in an in vitro model. RA may overestimate disease in patients with mountain-shaped plaques and may underestimate disease if the stenosis is <70%. Our data suggest that CA should not be the gold standard for the qualification of carotid endarterectomy in asymptomatic patients, nor for vascular laboratory quality assurance analysis.
Yoshida, Naohiro; Kinugasa, Tetsushi; Miyoshi, Hiroaki; Sato, Kensaku; Yuge, Kotaro; Ohchi, Takafumi; Fujino, Shinya; Shiraiwa, Sachiko; Katagiri, Mitsuhiro; Akagi, Yoshito; Ohshima, Koichi
2016-03-01
Tumor-infiltrating lymphocytes (TILs), part of the host immune response, have been widely reported as influential factors in the tumor microenvironment for the clinical outcome of colorectal cancer (CRC). However, the network of helper T cells is very complex, and which T-cell subtypes affect the progression of CRC and postoperative prognosis remains unclear. This study investigated the expression of several subtypes of TILs including T helper type 1 (Th1), Th2, Th17, and regulatory T (Treg) cells to determine their correlation with clinicopathologic features and postoperative prognosis. The study investigated the expression of TILs using immunohistochemistry of tissue microarray samples for 199 CRC patients. The number of each T-cell subtype infiltrating tumors was counted using ImageJ software. The relationship between TIL marker expression, clinicopathologic features, and prognosis was analyzed. A high RORγT/CD3 ratio (Th17 ratio) was significantly correlated with lymph node metastasis (p = 0.002), and a high of Foxp3/CD3 ratio (Treg ratio) was correlated with tumor location in the colon (p = 0.04), as shown by the Chi square test. In multivariate analysis, a high RORγT/CD3 ratio was the only independent prognostic factor for overall survival (p = 0.04; hazard ratio [HR], 1.84; 95% confidence interval [CI] 1.02-3.45). This study confirmed a high RORγT/CD3 ratio as a strong prognostic marker for postoperative survival. The immunohistochemistry results suggest that Th17 may affect lymph node metastasis in CRC. If new immunotherapies reducing Th17 expression are established, they may improve the efficiency of cancer treatment and prolong the survival of patients with CRC.
An Evaluation of Performance Characteristics of Primary Display Devices.
Ekpo, Ernest U; McEntee, Mark F
2016-04-01
The aim of this study was to complete a full evaluation of the new EIZO RX850 liquid crystal display and compare it to two currently used medical displays in Australia (EIZO GS510 and Barco MDCG 5121). The American Association of Physicists in Medicine (AAPM) Task Group 18 Quality Control test pattern was used to assess the performance of three high-resolution primary medical displays: EIZO RX850, EIZO GS510, and Barco MDCG 5121. A Konica Minolta spectroradiometer (CS-2000) was used to assess luminance response, non-uniformity, veiling glare, and color uniformity. Qualitative evaluation of noise was also performed. Seven breast lesions were displayed on each monitor and photographed with a calibrated 5.5-MP Olympus E-1 digital SLR camera. ImageJ software was used to sample pixel information from each lesion and surrounding background to calculate their conspicuity index on each of the displays. All monitor fulfilled all AAPM acceptance criteria. The performance characteristics for EIZO RX850, Barco MDCG 5121, and EIZO GS510 respectively were as follows: maximum luminance (490, 500.5, and 413 cd/m(2)), minimum luminance (0.724, 1.170, and 0.92 cd/m(2)), contrast ratio (675:1, 428:1, 449:1), just-noticeable difference index (635, 622, 609), non-uniformity (20, 5.92, and 8.5 %), veiling glare (GR = 2465.6, 720.4, 1249.8), and color uniformity (Δu'v' = +0.003, +0.002, +0.002). All monitors demonstrated low noise levels. The conspicuity index (χ) of the lesions was slightly higher in the EIZO RX850 display. All medical displays fulfilled AAPM performance criteria, and performance characteristics of EIZO RX850 are equal to or better than those of the Barco MDCG 5121 and EIZO GS510 displays.
COMPUTATIONAL ANALYSIS OF SWALLOWING MECHANICS UNDERLYING IMPAIRED EPIGLOTTIC INVERSION
Pearson, William G.; Taylor, Brandon K; Blair, Julie; Martin-Harris, Bonnie
2015-01-01
Objective Determine swallowing mechanics associated with the first and second epiglottic movements, that is, movement to horizontal and full inversion respectively, in order to provide a clinical interpretation of impaired epiglottic function. Study Design Retrospective cohort study. Methods A heterogeneous cohort of patients with swallowing difficulties was identified (n=92). Two speech-language pathologists reviewed 5ml thin and 5ml pudding videofluoroscopic swallow studies per subject, and assigned epiglottic component scores of 0=complete inversion, 1=partial inversion, and 2=no inversion forming three groups of videos for comparison. Coordinates mapping minimum and maximum excursion of the hyoid, pharynx, larynx, and tongue base during pharyngeal swallowing were recorded using ImageJ software. A canonical variate analysis with post-hoc discriminant function analysis of coordinates was performed using MorphoJ software to evaluate mechanical differences between groups. Eigenvectors characterizing swallowing mechanics underlying impaired epiglottic movements were visualized. Results Nineteen of 184 video-swallows were rejected for poor quality (n=165). A Goodman-Kruskal index of predictive association showed no correlation between epiglottic component scores and etiologies of dysphagia (λ=.04). A two-way analysis of variance by epiglottic component scores showed no significant interaction effects between sex and age (f=1.4, p=.25). Discriminant function analysis demonstrated statistically significant mechanical differences between epiglottic component scores: 1&2, representing the first epiglottic movement (Mahalanobis distance=1.13, p=.0007); and, 0&1, representing the second epiglottic movement (Mahalanobis distance=0.83, p=.003). Eigenvectors indicate that laryngeal elevation and tongue base retraction underlie both epiglottic movements. Conclusion Results suggest that reduced tongue base retraction and laryngeal elevation underlie impaired first and second epiglottic movements. The styloglossus, hyoglossus and long pharyngeal muscles are implicated as targets for rehabilitation in dysphagic patients with impaired epiglottic inversion. PMID:27426940
Scendoni, R; Ferrante, L; Stramazzotti, D; Tagliabracci, A
2016-11-01
Although establishing agony is crucial in forensic practice, the identification of specific signs indicative of a detailed duration of agony is however not of immediate execution. Nitric oxide (NO) is the most important messenger molecule in the modulation of vascular tone and it is produced during stress conditions by inducible nitric oxide synthase (iNOS), as occurs during agony. The aim of this study was to investigate the relationship between immunohistochemical expression of iNOS, and agonal time (T), defined as the interval between the onset of a hypoxic-ischemic injury and the death. INOS expression was evaluated by measuring the average of signal intensity (SI) from cytoplasm of 300 smooth muscle cells of sample of renal artery, performed by ImageJ software: high values of SI correspond to a low enzyme expression and vice versa. We aimed also to check if gender, age, type of death (violent or natural death), post mortem interval, and storage in cold chamber influenced SI. We assessed 50 autopsied cases, of which 28 violent and 22 natural deaths, with a well-known T in a range between 1 and 631 min. Statistical analysis was performed to estimate the relationship between SI and the other variables. Results pointed out that only SI is related to T, and since data showed a bi-phase relationship between T and SI, we used a piecewise regression method for estimation of T as function of SI. The transition from the first to the second phase takes place at SI = 117.5 which corresponds to a T of 29.5 min. In conclusion, the study demonstrates that iNOS is a good marker for estimating T and the final regression model can be used in many forensic activities.
Evaluation of 4 Different Irrigating Systems for Apical Extrusion of Sodium Hypochlorite.
Yost, Ross A; Bergeron, Brian E; Kirkpatrick, Timothy C; Roberts, Mark D; Roberts, Howard W; Himel, Van T; Sabey, Kent A
2015-09-01
The aim of this study was to evaluate NaOCl apical extrusion by using negative apical pressure (EndoVac), sonic agitation (EndoActivator), side-vented needle (Max-i-Probe), and photon induced photoacoustic streaming (PIPS 10 mJ and PIPS 20 mJ) laser irrigation in an in vitro gel model. Extracted mandibular and maxillary central incisors (n = 18) were prepared to size 35/.04 and 55/.04, respectively. Teeth were mounted in transparent containers with clear acrylic and suspended in a color-changing pH-sensitive gel, creating a closed system. By using a crossover design, each tooth was sequentially irrigated by using 6% NaOCl with each device following manufacturers' recommendations. Each tooth served as its own control. Pre-irrigation and post-irrigation buccal and proximal view photographs served to measure the longest distance of extrusion and were analyzed with ImageJ software. Mean results were analyzed by using Kruskal-Wallis and Dunn post hoc test (P < .05). There were no significant differences between EndoVac, EndoActivator, and the passive extrusion groups. The EndoVac and EndoActivator groups produced significantly less extrusion than PIPS irrigation. Max-i-Probe extrusion results were more variable than those of EndoActivator but had no significant difference. Across all irrigation systems, there were no significant differences with respect to apical preparation size. Under the in vitro conditions of this study, no difference was found between the 10 mJ and 20 mJ PIPS laser groups. EndoVac demonstrated significantly less potential for apical extrusion than PIPS and Max-i-Probe, whereas apical preparation size did not significantly affect extrusion of irrigant. The potential for apical extrusion of endodontic irrigants should be a consideration when selecting a system for final irrigation. Published by Elsevier Inc.
Development of the penis during the human fetal period (13 to 36 weeks after conception).
Gallo, Carla B M; Costa, Waldemar S; Furriel, Angelica; Bastos, Ana L; Sampaio, Francisco J B
2013-11-01
We analyzed the development of the area of the penis and erectile structures (corpora cavernosa and corpus spongiosum) and the thickness of the tunica albuginea during the fetal period (13 to 36 weeks after conception) in humans to establish normative patterns of growth. We studied 56 male human fetuses at 13 to 36 weeks after conception. We used histochemical and morphometric techniques to analyze the parameters of total penile area, area of corpora cavernosa, area of corpus spongiosum, and thickness of tunica albuginea in the dorsal and ventral regions using ImageJ software (National Institutes of Health, Bethesda, Maryland). Between 13 and 36 weeks after conception the area of the penis varies from 0.95 to 24.25 mm2. The area of the corpora cavernosa varies from 0.28 to 9.12 mm2, and the area of the corpus spongiosum varies from 0.14 to 3.99 mm2. The thickness of the tunica albuginea varies from 0.029 to 0.296 mm in the dorsal region and from 0.014 to 0.113 mm in the ventral region of the corpora cavernosa. We found a strong correlation between the total penile area, corpora cavernosa and corpus spongiosum with fetal age (weeks following conception). The growth rate was more intense during the second trimester (13 to 24 weeks of gestation) compared to the third trimester (25 to 36 weeks). Tunica albuginea thickness also was strongly correlated with fetal age and this structure was thicker in the dorsal vs ventral region. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Worthen, Wade B; Hart, Thomas M
2016-01-01
Some adult odonates resist parasitism by larval water mites (Arrenurus spp.) with melanotic encapsulation, in which the mite's stylestome is clogged and the mite starves. In summer 2014, we counted the engorged and resisted mites on 2,729 adult odonates sampled by aerial net at 11 water bodies in Greenville Co. and Pickens Co., SC, and tested the hypothesis that the frequency and intensity of resistance correlates with parasite prevalence (the percentage of parasitized hosts). Resistance prevalence (the percentage of parasitized hosts that resisted at least one mite) varied significantly among host species, exceeding 60% for Argia fumipennis(Burmeister) and Celithemis fasciata Kirby but less than 20% for other species. However, neither resistance prevalence nor mean resistance intensity (mean percentage of resisted mites on resisting hosts) correlated with parasite prevalence. We described potential effects of parasitism on host development ofA. fumipennis and Pachydiplax longipennis(Burmeister) by comparing the percent asymmetry of forewing lengths between parasitized and unparasitized individuals. There was no significant difference in asymmetry for either males or females of A. fumipennis, or males of Pa. longipennis(females were not sampled). We also evaluated differences in melanotic encapsulation between A. fumipennis, which readily encapsulates mites in nature, and Pa. longipennis We inserted a 2.0-mm piece of sterile monofilament line into the thorax of captured individuals for 24 h and compared mean gray value scores of inserted and emergent ends using Image-J software. There was no difference in melanotic encapsulation between species. © The Author 2016. Published by Oxford University Press on behalf of the Entomological Society of America.
Mulder, Jan; Hökfelt, Tomas; Knuepfer, Mark M.
2013-01-01
Efferent renal sympathetic nerves reinnervate the kidney after renal denervation in animals and humans. Therefore, the long-term reduction in arterial pressure following renal denervation in drug-resistant hypertensive patients has been attributed to lack of afferent renal sensory reinnervation. However, afferent sensory reinnervation of any organ, including the kidney, is an understudied question. Therefore, we analyzed the time course of sympathetic and sensory reinnervation at multiple time points (1, 4, and 5 days and 1, 2, 3, 4, 6, 9, and 12 wk) after renal denervation in normal Sprague-Dawley rats. Sympathetic and sensory innervation in the innervated and contralateral denervated kidney was determined as optical density (ImageJ) of the sympathetic and sensory nerves identified by immunohistochemistry using antibodies against markers for sympathetic nerves [neuropeptide Y (NPY) and tyrosine hydroxylase (TH)] and sensory nerves [substance P and calcitonin gene-related peptide (CGRP)]. In denervated kidneys, the optical density of NPY-immunoreactive (ir) fibers in the renal cortex and substance P-ir fibers in the pelvic wall was 6, 39, and 100% and 8, 47, and 100%, respectively, of that in the contralateral innervated kidney at 4 days, 4 wk, and 12 wk after denervation. Linear regression analysis of the optical density of the ratio of the denervated/innervated kidney versus time yielded similar intercept and slope values for NPY-ir, TH-ir, substance P-ir, and CGRP-ir fibers (all R2 > 0.76). In conclusion, in normotensive rats, reinnervation of the renal sensory nerves occurs over the same time course as reinnervation of the renal sympathetic nerves, both being complete at 9 to 12 wk following renal denervation. PMID:23408032
Takemoto, Yuko; Namba, Kenichi; Mizuuchi, Kazuomi; Iwata, Daiju; Uno, Tomoe; Ohno, Shigeaki; Hirooka, Kiriko; Hashimoto, Yuki; Saito, Wataru; Sugiyama, Kazuhisa; Ishida, Susumu
2016-11-01
To assess choroidal inflammation-related circulatory changes associated with the anterior recurrence of Vogt-Koyanagi-Harada (VKH) disease, using indocyanine green angiography (ICGA) and laser speckle flowgraphy (LSFG). This retrospective case series included 17 eyes of 11 patients with VKH disease showing recurrent inflammatory findings in the anterior, but not posterior, segment (i.e. anterior recurrence). Indocyanine green angiography (ICGA) and LSFG were performed at the time of recurrence and one month after the initiation of corticosteroid therapy. The number and total area of hypofluorescent dark dots (HDDs) on ICGA were independently counted by three physicians and measured with ImageJ, respectively. Mean blur rate (MBR), a quantitative index of relative blood flow velocity, was calculated via the LSFG Analyzer software. Hypofluorescent dark dots (HDDs) were identified on ICGA in 13 of 17 eyes (76%) with the anterior recurrence of VKH disease. The number and total area of HDDs significantly decreased from 203 ± 101 dots to 59 ± 51 dots and from 48 789 ± 24 251 pixels to 15 664 ± 13 254 pixels, respectively. The change ratio of MBR significantly increased by 17.9 ± 16.3% after the treatment. Importantly, there was no significant association between the change ratios of HDDs and MBR. These findings on LSFG and ICGA clearly demonstrated subclinical involvement as well as post-treatment improvement of choroidal circulation impairment due to granulomatous inflammation in eyes with the anterior recurrence of VKH disease. The present data suggest the validity of using these two examinations, capable of detecting different circulatory changes, in the management of recurrent VKH disease. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
α-Synuclein staging in the amygdala of a Parkinson's disease model: cell types involved.
Flores-Cuadrado, Alicia; Ubeda-Bañon, Isabel; Saiz-Sanchez, Daniel; de la Rosa-Prieto, Carlos; Martinez-Marcos, Alino
2015-01-01
Lewy bodies (ubiquitin and α-synuclein aggregates) can be detected in brain areas in a predictable sequence of six neuropathological stages in Parkinson's disease. Brainstem and olfactory structures are involved in stage 1, whereas the substantia nigra and amygdala are involved in stage 3, prior to cortical spreading. Amygdaloid pathology has been suggested to contribute to non-motor symptoms such as olfactory dysfunction and emotional impairment. This work analysed the distribution of α-synuclein at 16, 30, 43 and 56 weeks in the basolateral, central and cortical amygdaloid complexes of A53T transgenic mice. The expression of calbindin, calretinin and somatostatin was compared in control and transgenic animals. Co-localisation of these markers with α-synuclein was performed. Triple labeling of calbindin, somatostatin and α-synuclein was also investigated. Quantification was carried out using an optical dissector, ImageJ software and confocal microscopy. α-Synuclein-positive cells were mainly concentrated in the basolateral and cortical amygdaloid complexes with a non-significant increase over time from 16 to 30-43 weeks and a significant decrease thereafter. The expression of interneuron markers showed a significant decrease with aging in control animals. When comparing these markers between control and transgenic mice, calretinin was moderately decreased, but calbindin and somatostatin were highly reduced, particularly in the cortical amygdaloid complex. α-Synuclein mostly co-localised with calbindin and a number of these cells also co-expressed somatostatin. These data on α-synucleinopathy staging in the amygdala could help to explain non-motor symptoms as well as to understand the progression of Parkinson's disease in the brain. © 2014 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.
Ex vivo tracheomalacia model with 3D-printed external tracheal splint.
Kaye, Rachel; Goldstein, Todd; Aronowitz, Danielle; Grande, Daniel A; Zeltsman, David; Smith, Lee P
2017-04-01
To design and evaluate an ex vivo model of tracheomalacia with and without a three-dimensional (3D)-printed external tracheal splint. Prospective, ex vivo animal trial. Three groups of ex vivo porcine tracheas were used: 1) control (unmanipulated trachea), 2) tracheomalacia (tracheal rings partially incised and crushed), and 3) splinted tracheomalacia (external custom tracheal splint fitted onto group 2 trachea). Each end of an ex vivo trachea was sealed with a custom-designed and 3D-printed cap; a transducer was placed through one end to measure the pressure inside the trachea. Although the negative pressure was applied to the tracheal lumen, the tracheal wall collapse was measured externally and internally using a bronchoscope. Each group had at least three recorded trials. Tracheal diameter was evaluated using ImageJ software (National Institutes of Health, Bethesda, MD) and was averaged between two raters. Average tracheal occlusion percentage was compared using Student t test. The average occlusion was 31% for group 1, 87.4% for group 2, and 20% for group 3. Significant differences were found between the control and tracheomalacia groups (P < 0.01) and the tracheomalacia and splinted tracheomalacia groups (P < 0.01). There was no significant difference between the control and splinted tracheomalacia groups (P = 0.13). Applied pressure was plotted against occlusion and regression line slope differed between the tracheomalacia (0.91) and control (0.12) or splinted tracheomalacia (0.39) groups. We demonstrate the potential for an ex vivo tracheomalacia model to reproduce airway collapse and show that this collapse can be treated successfully with a 3D-printed external splint. These results are promising and justify further studies. N/A. Laryngoscope, 127:950-955, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Chen, Hong-Bin; Lian-Xiang, Peng; Yue, Huang; Chun, Huang; Shu-Ping, Xiao; Rong-Pang, Lin; Xiao-Zong, Wang; Xiao-Lin, Li
2017-10-01
The approach to small bowel preparation before capsule endoscopy (CE) is still suboptimal. One hundred eighty patients were randomly allocated to 3 groups. Patients in Group A took 250 mL 20% mannitol and 1 L 0.9% saline orally at 05:00 hours on the day of the procedure. In Group B the same preparation was taken at 20:00 on the day before, and at 05:00 on the day of CE; in addition, 20 mL oral simethicone was taken 30 minutes before CE. Group C was treated identically to Group B, except that the patients fasted for 3 days and took 3 g senna orally 3 times daily before CE. The length of bowel containing green luminal contents was assessed by ImageJ software and bowel cleanliness was evaluated by computed assessment of the cleansing score. Cleansing of the whole small bowel and the distal small bowel were significantly different between the 3 groups (χ = 22.470, P = .000; χ = 17.029, P = .000, respectively). There were also significant differences between the 3 groups in the length of small bowel and specifically the length of the distal small bowel containing green luminal contents (χ = 12.390, P = .000, χ = 15.141, P = .000, respectively), but not with regard to the proximal small bowel (χ = 0.678, P = .509). Three days fasting and oral senna, combined with 20% mannitol and simethicone, before CE, can reduce the effects of bile on the small bowel and improve small bowel cleansing, especially in the distal small intestine.
Kalita, Jayantee; Kumar, Vijay; Misra, Usha K; Bora, Himangsu K
2018-05-01
The prototype disease of Cu toxicity in human is Wilson disease, and cognitive impairment is the presenting symptom of it. There is no study correlating Cu-induced excitotoxicity, apoptosis, and astrocytic reaction with memory dysfunction. We report excitotoxicity, apoptosis, and astrocytic reaction of the hippocampus and frontal cortex with memory dysfunction in rat model of Cu toxicity. Thirty-six rats were divided into group I (control) and group II (100 mg/kgBwt/day CuSO 4 orally). Y-maze was performed for memory and learning at 0, 30, 60, and 90 days. Frontal and hippocampal free Cu concentration, oxidative stress markers [glutathione (GSH), total antioxidant toxicity (TAC), and malondialdehyde (MDA)], and glutamate were measured by atomic absorption spectroscopy, spectrophotometry, and ELISA, respectively. N-methyl-D-aspartate receptors (NMDARs) NR1, NR2A, and NR2B were done by real-time polymerase chain reaction. Immunohistochemistry for caspase-3 and glial fibrillary acidic protein (GFAP) were done and quantified using the ImageJ software. The glutamate level in hippocampus was increased, and NMDAR expression was decreased at 30, 60, and 90 days in group II compared to group I. In the frontal cortex, glutamate was increased at 90 days, but NMDARs were not significantly different in group II compared to group I. Caspase-3 and GFAP expressions were also higher in group II compared to group I, and these changes were more marked in hippocampus than frontal cortex. These changes correlated with respective free tissue Cu, oxidative stress, and Y-maze attention score. Cu toxicity induces apoptosis and astrocytosis of the hippocampus and frontal cortex through direct or glutamate and oxidative stress pathways, and results in impaired memory and learning.
Islam, Muhammad Nazrul; Zhu, Xiao Bo; Zhu, Ziao Bo; Aoyama, Masato; Sugita, Shoei
2010-09-01
A histological and morphometric study was conducted to examine the seasonal testicular variations in the Jungle Crow (Corvus macrorhynchos) of the Kanto area, Japan, from January to July. The paired testes mass, diameter and number of germ cells of the seminiferous tubules, and proportion of seminiferous tubule area and interstitium were examined. Hematoxylin and eosin-stained testis sections and ImageJ Software were used. Paired testes weight was found to increase by 55-fold from January to late March-early May, thereafter declining by 18-fold by June-July. Seminiferous tubule diameter increased fivefold from January to late March-early May, followed a fourfold decrease in June-July. The increase in testes weight correlated well with the increase in the diameter of the seminiferous tubule. In January, the seminiferous tubules constituted 56% of the testicular tissue and the interstitium 44%. During late March-early May, there was very little testicular interstitium (7.9%), and the seminiferous tubules were significantly enlarged (P < 0.05) (92%); this was followed by a gradual increase in the interstitial regression of testes. In January, the seminiferous epithelium contained a single layer of spermatogonia and Sertoli cells. The number of spermatogonia, primary and secondary spermatocytes, spermatids, and maturing spermatozoa were significantly increased (P < 0.05) in late March-early May, followed by regression from mid May. Our results indicate that the Jungle Crow has a non-breeding season in January, a pre-breeding season during February-mid March, a main breeding season during late March-early May, a transition period during mid May-late May, and a post-breeding season beginning in June.
Seasonal morphological changes in the ovary of the Jungle crow (Corvus macrorhynchos).
Islam, Muhammad Nazrul; Zhu, Xiao Bo; Aoyama, Masato; Sugita, Shoei
2010-12-01
Morphometric and histological studies were conducted to examine the seasonal ovarian changes in the Jungle crow of the Kanto area, Japan, from December to June. The ovary weights, largest diameters and atresias of the ovarian follicles and steroid-producing cells were examined. Hematoxylin and eosin-stained ovary sections and ImageJ software were used. The most developed ovary weight increased 373-fold in April, compared to those in December, followed by a 29-fold decrease in June. The average largest follicle diameter of the December and the January ovaries were 1.03 ± 0.35 and 1.05 ± 0.3 mm, respectively. The average largest follicle diameter increased by 2-fold in February, 4-fold in March and 8-fold in April, compared to those of December and January. Thereafter, the average largest follicle diameter declined by 6-fold in June. The average ovary weight and the largest follicle diameter in April increased significantly (P < 0.05) compared to those of December and January, followed by a significant decrease (P < 0.05) in June. The ovary weight correlated well with the expansion of the largest follicular diameter. Non-bursting and bursting atresias of smaller follicles were more common in the December, January, February and June ovaries, and bursting atresias of larger follicles were more common in the March, April and May ovaries. Ovarian steroidogenic cells became heavily charged with lipids in December, January, February and June, and they depleted their lipids in March and April, which might be due to steroid synthesis. Our results indicate that there are significant seasonal histomorphologic variations in the Jungle crow ovary.
Human organotypic retinal flat-mount culture (HORFC) as a model for retinitis pigmentosa11.
Azizzadeh Pormehr, Leila; Daftarian, Narsis; Ahmadian, Shahin; Rezaei Kanavi, Mozhgan; Ahmadieh, Hamid; Shafiezadeh, Mahshid
2018-05-10
The splicing factor PRPF31 is the most commonly mutated general splicing factor in the retinitis pigmentosa. We used a rapid, convenient and cost effective transfection method with an efficient PRPF31 knockdown in HORFC in order to study the effect of PRPF31 downregulation on retinal gene expressions in an ex vivo model. Modified calcium phosphate method was used to transfect HORFC by PRPF31 siRNA. Different times and doses of siRNA for transfection were assayed and optimum condition was obtained. PRPF31 mRNA and protein downregulation were assessed by qRTPCR and Western blot. The tissue viability of HORFC was measured using the MTT. ImageJ analysis on stained retinal sections by immunohistochemistry was used for thickness measurement of outer nuclear photoreceptor layer. The PRPF31 gene downregulation effects on retinal specific gene expression were analyzed by qRTPCR. A total of 50 nM of PRPF31 siRNA transfection after 63 h in HORFC, showed the optimum reduction in the level of PRPF31 mRNA and protein as shown by qRTPCR and Western blot (over 90% and 50% respectively). The PRPF31 mRNA silencing with calcium phosphate had no effect on cell viability in the period of the experiment. Thickness measurement of outer nuclear photoreceptor layer with IHC showed the significant reduction after 63 h of study (P value = 0.02). siRNA induced PRPF31 knockdown, led to reduction of retinal specific mRNA gene expression involved in phototransduction (RHO, GNAT1, RP1), photoreceptor structure (ROM1, FSCN2, CA4, SEMA4) and transcription factor (CRX) (fold change >5), after 63 h. © 2018 Wiley Periodicals, Inc.
Malik, Shabana T; Birch, Brian R; Voegeli, David; Fader, Mandy; Foria, Vipul; Cooper, Alan J; Walls, Andrew F; Lwaleed, Bashir A
2018-05-15
To identify the presence and geographical distribution of mast cell (MC) subtypes: MC T (tryptase positive-chymase negative) and MC TC (tryptase positive-chymase positive) in bladder tissue. Bladder tissue was obtained from patients with painful bladder syndrome/interstitial cystitis (n=14) and normal histology from University Hospital Southampton tissue bank. Sequential tissue slices were immunohistochemically stained for MC subtypes using anti-MC tryptase (for MC T and MC TC ) and anti-MC chymase (for MC TC ). Stained sections were photographed, and positively stained MCs were quantified using ImageJ. Data were analysed using descriptive statistics and individual paired t-tests. There was a significant difference in the density of MCs between each layer of the disease bladder, with the greatest accumulation within the detrusor (p<0.001). There was a significant increase in MC TC subtype in the lamina (p=0.009) in painful bladder syndrome/interstitial cystitis. Our results suggest that mastocytosis is present within all layers of disease bladder, especially the muscle layer. The varying increase in MC subtypes in the lamina and mucosa may explain the variability in painful bladder syndrome/interstitial cystitis symptoms. A high influx of MC TC in the mucosa of individuals who also had ulceration noted within their diagnostic notes may be of the Hunner's ulcer subclassification. These findings suggest a relationship between the pathogenesis of MC subtypes and the clinical presentation of painful bladder syndrome/interstitial cystitis. A cohort study would further elucidate the diagnostic and/or therapeutic potential of MCs in patients with painful bladder syndrome/interstitial cystitis. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
The Effect of Thickness of ZnO Thin Films on Hydrophobic Self-Cleaning Properties
NASA Astrophysics Data System (ADS)
Mufti, N.; Arista, D.; Diantoro, M.; Fuad, A.; Taufiq, A.; Sunaryono
2017-05-01
Glass coating can be conducted by using ZnO-photocatalyst based semiconductor material since it is preeminent in decomposing organics compound and dangerous bacteria which often contaminates the environment. If there are dirt containing organics compound on the glass, the ZnO photocatalyst coat can be applied as self-cleaning, usually called self-cleaning glass. It depends on the coating thickness which can be controlled by setting the speed of spin coating. In this research, the various rotating speeds of spin coating were conducted at 2000 rpm, 3000 rpm, and 4000 rpm to control the thickness. The raw materials used in this research were Zn(CH3COOH)2.2H2O (PA 99,5%), Ethylene glycol, Diethanolamine (PA 99%), Isopropanol Alkohol, Glycerol, and Ashton. Synthesis methods used were sol-gel prior to spin coating technic were applied. The results of the film were characterized by using SEM, XRD, and UV-Spectrophotometer. The crystal structure was analyzed by using Highscore plus and GSAS software, the size crystal was calculated by using Scherrer equation, a contact angle with ImageJ software. It was shown that ZnO thin film had been successfully synthesized with the crystal size around 21 nm up to 26 nm. The absorption value is higher due to the increasing of coat thickness with bandgap ± 3.2 eV. The test result of hydrophobic and hydrophilic characteristics show that all samples of ZnO thin film with the thickness ± 1.050 μm, ± 0.450 μm, ± 0.250 μm can be applied as self-cleaning glass. The best result was gained with the thickness of thin film ± 1.050 μm.
Remote Sensing Image Quality Assessment Experiment with Post-Processing
NASA Astrophysics Data System (ADS)
Jiang, W.; Chen, S.; Wang, X.; Huang, Q.; Shi, H.; Man, Y.
2018-04-01
This paper briefly describes the post-processing influence assessment experiment, the experiment includes three steps: the physical simulation, image processing, and image quality assessment. The physical simulation models sampled imaging system in laboratory, the imaging system parameters are tested, the digital image serving as image processing input are produced by this imaging system with the same imaging system parameters. The gathered optical sampled images with the tested imaging parameters are processed by 3 digital image processes, including calibration pre-processing, lossy compression with different compression ratio and image post-processing with different core. Image quality assessment method used is just noticeable difference (JND) subject assessment based on ISO20462, through subject assessment of the gathered and processing images, the influence of different imaging parameters and post-processing to image quality can be found. The six JND subject assessment experimental data can be validated each other. Main conclusions include: image post-processing can improve image quality; image post-processing can improve image quality even with lossy compression, image quality with higher compression ratio improves less than lower ratio; with our image post-processing method, image quality is better, when camera MTF being within a small range.
Irons, Robin F; Cahill, Kevin W; Rattigan, Deviney A; Marcotte, Joseph H; Fromer, Marc W; Chang, Shaohua; Zhang, Ping; Behling, Eric M; Behling, Kathryn C; Caputo, Francis J
2018-05-09
The purpose of our study was to investigate the effect of adipose-derived stem cells (ASCs), endothelial-differentiated ASCs (EC/ASCs), and various conditioned media (CM) on wound healing in a diabetic swine model. We hypothesized that ASC-based therapies would accelerate wound healing. Diabetes was induced in four Yorkshire swine through intravenous injection of streptozotocin. ASCs were harvested from flank fat and cultured in either M199 or EGM-2 medium. A duplicate series of seven full-thickness dorsal wounds were surgically created on each swine. The wounds in the cellular treatment group underwent injection of low-dose or high-dose ASCs or EC/ASCs on day 0, with a repeat injection of one half of the initial dose on day 15. Wounds assigned to the topical CM therapy were covered with 2 mL of either serum-free M199 primed by ASCs or human umbilical vein endothelial cells every 3 days. Wounds were assessed at day 0, 10, 15, 20, and 28. The swine were sacrificed on day 28. ImageJ software was used to evaluate the percentage of wound healing. The wounded skin underwent histologic, reverse transcription polymerase chain reaction, and enzyme-linked immunosorbent assay examinations to evaluate markers of angiogenesis and inflammation. We found an increase in the percentage of wound closure rates in cell-based treatments and topical therapies at various points compared with the untreated control wounds (P < .05). The results from the histologic, messenger RNA, and protein analyses suggested the treated wounds displayed increased angiogenesis and a diminished inflammatory response. Cellular therapy with ASCs, EC/ASCs, and topical CM accelerated diabetic wound healing in the swine model. Enhanced angiogenesis and immunomodulation might be key contributors to this process. The purpose of the present study was to translate the known beneficial effects of adipose-derived stem cells and associated conditioned medium therapy on diabetic wound healing to a large animal model. We demonstrated that stem cell and conditioned medium therapy significantly accelerate gross wound healing in diabetic swine, with data suggesting this might result from a decreased inflammatory response and increased angiogenesis. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Maurer, Thomas; Gustavos Trujillo Siliézar, Carlos; Oeser, Anne; Pohle, Ina; Hinz, Christoph
2016-04-01
In evolving initial landscapes, vegetation development depends on a variety of feedback effects. One of the less understood feedback loops is the interaction between throughfall and plant canopy development. The amount of throughfall is governed by the characteristics of the vegetation canopy, whereas vegetation pattern evolution may in turn depend on the spatio-temporal distribution of throughfall. Meteorological factors that may influence throughfall, while at the same time interacting with the canopy, are e.g. wind speed, wind direction and rainfall intensity. Our objective is to investigate how throughfall, vegetation canopy and meteorological variables interact in an exemplary eco-hydrological system in its initial development phase, in which the canopy is very heterogeneous and rapidly changing. For that purpose, we developed a methodological approach combining field methods, raster image analysis and multivariate statistics. The research area for this study is the Hühnerwasser ('Chicken Creek') catchment in Lower Lusatia, Brandenburg, Germany, where after eight years of succession, the spatial distribution of plant species is highly heterogeneous, leading to increasingly differentiated throughfall patterns. The constructed 6-ha catchment offers ideal conditions for our study due to the rapidly changing vegetation structure and the availability of complementary monitoring data. Throughfall data were obtained by 50 tipping bucket rain gauges arranged in two transects and connected via a wireless sensor network that cover the predominant vegetation types on the catchment (locust copses, dense sallow thorn bushes and reeds, base herbaceous and medium-rise small-reed vegetation, and open areas covered by moss and lichens). The spatial configuration of the vegetation canopy for each measurement site was described via digital image analysis of hemispheric photographs of the canopy using the ArcGIS Spatial Analyst, GapLight and ImageJ software. Meteorological data from two on-site weather stations (wind direction, wind speed, air temperature, air humidity, insolation, soil temperature, precipitation) were provided by the 'Research Platform Chicken Creek' (https://www.tu-cottbus.de/projekte/en/oekosysteme/startseite.html). Data were combined and multivariate statistical analysis (PCA, cluster analysis, regression trees) were conducted using the R-software to i) obtain statistical indices describing the relevant characteristics of the data and ii) to identify the determining factors for throughfall intensity. The methodology is currently tested and results will be presented. Preliminary evaluation of the image analysis approach showed only marginal, systematic deviation of results for the different software tools applied, which makes the developed workflow a viable tool for canopy characterization. Results from this study will have a broad spectrum of possible applications, for instance the development / calibration of rainfall interception models, the incorporation into eco-hydrological models, or to test the fault tolerance of wireless rainfall sensor networks.
Automated grading system for evaluation of ocular redness associated with dry eye
Rodriguez, John D; Johnston, Patrick R; Ousler, George W; Smith, Lisa M; Abelson, Mark B
2013-01-01
Background We have observed that dry eye redness is characterized by a prominence of fine horizontal conjunctival vessels in the exposed ocular surface of the interpalpebral fissure, and have incorporated this feature into the grading of redness in clinical studies of dry eye. Aim To develop an automated method of grading dry eye-associated ocular redness in order to expand on the clinical grading system currently used. Methods Ninety nine images from 26 dry eye subjects were evaluated by five graders using a 0–4 (in 0.5 increments) dry eye redness (Ora Calibra™ Dry Eye Redness Scale [OCDER]) scale. For the automated method, the Opencv computer vision library was used to develop software for calculating redness and horizontal conjunctival vessels (noted as “horizontality”). From original photograph, the region of interest (ROI) was selected manually using the open source ImageJ software. Total average redness intensity (Com-Red) was calculated as a single channel 8-bit image as R – 0.83G – 0.17B, where R, G and B were the respective intensities of the red, green and blue channels. The location of vessels was detected by normalizing the blue channel and selecting pixels with an intensity of less than 97% of the mean. The horizontal component (Com-Hor) was calculated by the first order Sobel derivative in the vertical direction and the score was calculated as the average blue channel image intensity of this vertical derivative. Pearson correlation coefficients, accuracy and concordance correlation coefficients (CCC) were calculated after regression and standardized regression of the dataset. Results The agreement (both Pearson’s and CCC) among investigators using the OCDER scale was 0.67, while the agreement of investigator to computer was 0.76. A multiple regression using both redness and horizontality improved the agreement CCC from 0.66 and 0.69 to 0.76, demonstrating the contribution of vessel geometry to the overall grade. Computer analysis of a given image has 100% repeatability and zero variability from session to session. Conclusion This objective means of grading ocular redness in a unified fashion has potential significance as a new clinical endpoint. In comparisons between computer and investigator, computer grading proved to be more reliable than another investigator using the OCDER scale. The best fitting model based on the present sample, and usable for future studies, was C4=−12.24+2.12C2HOR+0.88C2RED:C4 is the predicted investigator grade, and C2HOR and C2RED are logarithmic transformations of the computer calculated parameters COM-Hor and COM-Red. Considering the superior repeatability, computer automated grading might be preferable to investigator grading in multicentered dry eye studies in which the subtle differences in redness incurred by treatment have been historically difficult to define. PMID:23814457
Sensakovic, William F; O'Dell, M Cody; Letter, Haley; Kohler, Nathan; Rop, Baiywo; Cook, Jane; Logsdon, Gregory; Varich, Laura
2016-10-01
Image processing plays an important role in optimizing image quality and radiation dose in projection radiography. Unfortunately commercial algorithms are black boxes that are often left at or near vendor default settings rather than being optimized. We hypothesize that different commercial image-processing systems, when left at or near default settings, create significant differences in image quality. We further hypothesize that image-quality differences can be exploited to produce images of equivalent quality but lower radiation dose. We used a portable radiography system to acquire images on a neonatal chest phantom and recorded the entrance surface air kerma (ESAK). We applied two image-processing systems (Optima XR220amx, by GE Healthcare, Waukesha, WI; and MUSICA(2) by Agfa HealthCare, Mortsel, Belgium) to the images. Seven observers (attending pediatric radiologists and radiology residents) independently assessed image quality using two methods: rating and matching. Image-quality ratings were independently assessed by each observer on a 10-point scale. Matching consisted of each observer matching GE-processed images and Agfa-processed images with equivalent image quality. A total of 210 rating tasks and 42 matching tasks were performed and effective dose was estimated. Median Agfa-processed image-quality ratings were higher than GE-processed ratings. Non-diagnostic ratings were seen over a wider range of doses for GE-processed images than for Agfa-processed images. During matching tasks, observers matched image quality between GE-processed images and Agfa-processed images acquired at a lower effective dose (11 ± 9 μSv; P < 0.0001). Image-processing methods significantly impact perceived image quality. These image-quality differences can be exploited to alter protocols and produce images of equivalent image quality but lower doses. Those purchasing projection radiography systems or third-party image-processing software should be aware that image processing can significantly impact image quality when settings are left near default values.
NASA Astrophysics Data System (ADS)
Anderson, L.; Lechaire, J.; Frebourg, G.; Boudier, T.; Zbinden, M.; Gaill, F.
2005-12-01
The chemical and temperature conditions around deep sea hydrothermal vents are both dynamic and extreme, yet the shrimp Rimicaris exoculata flourishes around these environments on the Mid-Atlantic Ridge (MAR) . The epibiotic bacteria and minerals found within the branchial chamber of the shrimp are of great interest in the search for a chemical model for the Rainbow MAR hydrothermal vent site. Here we examine the close three-dimensional (3D) relationship between bacteria (on inner surface of the branchial chamber wall), and the minerals that surround them. The morphology and chemistry of the minerals were analysed by Transmission Electron Microscopy (TEM) and Energy-filtering Transmission Electron Microscopy (EFTEM, LEO 912 Omega) respectively, and the 3D organisation (TOMO) was established using IMAGE-J (public-domain) tomographic reconstruction software. Samples of Rimicaris exoculata were collected from the Rainbow site (36° 13' N, 2320 m depth). The cuticle of the branchial chamber was cut into 2mm wide sub-samples, dehydrated and impregnated in resin for cutting. Consecutive thin and semi-thin sections of 80μm (for TEM, EFTEM) and 150μm-200μm (for TOMO) were cut and mounted on standard microscope grids. Thin-section grids were observed initially for morphology, to find broad relationships between bacteria and minerals, and also as a tool to find areas for EFTEM analysis and TOMO. The TOMO reconstruction was produced from a `Tilt Series', comprising a number of images taken at one degree increments between -55° and +55°. Tilt series were obtained using the ESIvision program (Version 3.0, Soft' Imaging Software, SIS GmbH, D-49153 Münster, Germany) with additional in-house scripts for automated acquisition. This same procedure was applied to consecutive semi-thin sections through the same sub-sample. The different series for each sub-sample were then overlain to obtain a 3D overview of the bacteria-mineral associations. In many cases the minerals exhibit a sharp boundary against the bacteria, often with a substantial void between bacterial membrane and mineral boundary. Mineral layering and areas of elemental zoning are also observed. Iron is the most prevalent element, with a close association to the bacteria. Future work will combine the elemental data obtained by EFTEM with tomography to produce a 3D elemental map of the minerals surrounding the bacteria, focussing particularly on the bacteria-mineral interface using recently developed EFTET-J software (http://www.snv.jussieu.fr/~wboudier/softs.html).
Evaluating blood perfusion of the corpus luteum in beef cows during fescue toxicosis.
Cline, G F; Muth-Spurlock, A M; Voelz, B E; Lemley, C O; Larson, J E
2016-01-01
The aim of this study was to determine if fescue toxicosis altered blood perfusion in the corpus luteum (CL) and peripheral concentrations of progesterone in cattle. The estrous cycles of 36 nonpregnant Angus or Charolais cows were synchronized in 2 replicates using the CO-Synch+CIDR protocol. Seven days after initiation of the protocol, cows were assigned (d 0) to 1 of 2 dietary treatments: 2.5 kg of 1) Kentucky-31 endophyte-infected (KY31; = 14) or 2) MaxQ novel endophyte (MaxQ; = 12) tall fescue seed. On d 7, ovaries were examined using ultrasonography, and only cows that had 1 CL present remained on the study ( = 26). Images of blood perfusion of CL, blood samples, rectal temperatures, and blood pressure of tails were collected on d 10, 13, 15, and 18. Images of CL blood perfusion were analyzed using ImageJ software for pixel density, and scored visually (0 to 9 with 0 = no perfusion, 9 = complete perfusion) by 2 independent technicians. The MIXED procedure of SAS was used with day as a repeated measure. Least squares means and SEM are reported. Cows receiving KY31 had greater rectal temperatures ( 0.003; 38.76 ± 0.08°C) than those receiving MaxQ (38.44 ± 0.08°C), providing evidence that the cows treated with KY31 were influenced by fescue toxicosis. Pulse pressure and mean arterial pressure were decreased ( < 0.01) in cows receiving KY31 (55.26 ± 2.81 and 80.06 ± 2.72 mmHg, respectively) than MaxQ (66.58 ± 3.03 and 91.38 ± 2.93 mmHg, respectively). Concentrations of progesterone were similar ( = 0.54) between cows receiving KY31 (6.04 ± 0.53 ng/mL) or MaxQ (6.36 ± 0.63 ng/mL). Pixel densities ( = 0.14) and visual perfusion scores were similar ( = 0.11) between cows receiving KY31 (1477.20 ± 655.62 pixels and 2.23 ± 0.34, respectively) or MaxQ (2934.70 ± 718.20 pixels and 3.00 ± 0.36, respectively). Mean CL volume was similar ( 0.95) between treatments. In conclusion, blood perfusion of CL or peripheral concentrations of progesterone were not altered at the onset of fescue toxicosis in this short-term study, indicating that a decrease in blood perfusion of the CL may not be a primary mechanism involved in decreased reproductive efficiency of cattle during fescue toxicosis.
Fuzzy image processing in sun sensor
NASA Technical Reports Server (NTRS)
Mobasser, S.; Liebe, C. C.; Howard, A.
2003-01-01
This paper will describe how the fuzzy image processing is implemented in the instrument. Comparison of the Fuzzy image processing and a more conventional image processing algorithm is provided and shows that the Fuzzy image processing yields better accuracy then conventional image processing.
Methods in Astronomical Image Processing
NASA Astrophysics Data System (ADS)
Jörsäter, S.
A Brief Introductory Note History of Astronomical Imaging Astronomical Image Data Images in Various Formats Digitized Image Data Digital Image Data Philosophy of Astronomical Image Processing Properties of Digital Astronomical Images Human Image Processing Astronomical vs. Computer Science Image Processing Basic Tools of Astronomical Image Processing Display Applications Calibration of Intensity Scales Calibration of Length Scales Image Re-shaping Feature Enhancement Noise Suppression Noise and Error Analysis Image Processing Packages: Design of AIPS and MIDAS AIPS MIDAS Reduction of CCD Data Bias Subtraction Clipping Preflash Subtraction Dark Subtraction Flat Fielding Sky Subtraction Extinction Correction Deconvolution Methods Rebinning/Combining Summary and Prospects for the Future
Automated synthesis of image processing procedures using AI planning techniques
NASA Technical Reports Server (NTRS)
Chien, Steve; Mortensen, Helen
1994-01-01
This paper describes the Multimission VICAR (Video Image Communication and Retrieval) Planner (MVP) (Chien 1994) system, which uses artificial intelligence planning techniques (Iwasaki & Friedland, 1985, Pemberthy & Weld, 1992, Stefik, 1981) to automatically construct executable complex image processing procedures (using models of the smaller constituent image processing subprograms) in response to image processing requests made to the JPL Multimission Image Processing Laboratory (MIPL). The MVP system allows the user to specify the image processing requirements in terms of the various types of correction required. Given this information, MVP derives unspecified required processing steps and determines appropriate image processing programs and parameters to achieve the specified image processing goals. This information is output as an executable image processing program which can then be executed to fill the processing request.
The effect of image processing on the detection of cancers in digital mammography.
Warren, Lucy M; Given-Wilson, Rosalind M; Wallis, Matthew G; Cooke, Julie; Halling-Brown, Mark D; Mackenzie, Alistair; Chakraborty, Dev P; Bosmans, Hilde; Dance, David R; Young, Kenneth C
2014-08-01
OBJECTIVE. The objective of our study was to investigate the effect of image processing on the detection of cancers in digital mammography images. MATERIALS AND METHODS. Two hundred seventy pairs of breast images (both breasts, one view) were collected from eight systems using Hologic amorphous selenium detectors: 80 image pairs showed breasts containing subtle malignant masses; 30 image pairs, biopsy-proven benign lesions; 80 image pairs, simulated calcification clusters; and 80 image pairs, no cancer (normal). The 270 image pairs were processed with three types of image processing: standard (full enhancement), low contrast (intermediate enhancement), and pseudo-film-screen (no enhancement). Seven experienced observers inspected the images, locating and rating regions they suspected to be cancer for likelihood of malignancy. The results were analyzed using a jackknife-alternative free-response receiver operating characteristic (JAFROC) analysis. RESULTS. The detection of calcification clusters was significantly affected by the type of image processing: The JAFROC figure of merit (FOM) decreased from 0.65 with standard image processing to 0.63 with low-contrast image processing (p = 0.04) and from 0.65 with standard image processing to 0.61 with film-screen image processing (p = 0.0005). The detection of noncalcification cancers was not significantly different among the image-processing types investigated (p > 0.40). CONCLUSION. These results suggest that image processing has a significant impact on the detection of calcification clusters in digital mammography. For the three image-processing versions and the system investigated, standard image processing was optimal for the detection of calcification clusters. The effect on cancer detection should be considered when selecting the type of image processing in the future.
DOE Office of Scientific and Technical Information (OSTI.GOV)
González, M. A. Pagnan, E-mail: miguelangel.pagnan@hotmail.com; Mitsoura, E., E-mail: meleni@uaemex.mx; Oviedo, J.O. Hernández
Mycosis fungoides is a cutaneous lymphoma that accounts for 2–3% of all lymphomas. Several clinical studies have demonstrated the effectiveness of TSEBT (Total Skin Electron Beam Therapy) in patients with mycosis fungoides. It is important to develop this technique and make it available to a larger number of patients in Mexico. Because large fields for electron TSEBT are required in order to cover the entire body of the patient, beam characterization at conventional treatment distances is not sufficient and a calibration distance of 500cm or higher is required. Materials and methods: Calibration of radiochromic Gafchromic® EBT2 film (RCF) for electronsmore » was performed in a solid water phantom (Scanditronix Wellhöfer) at a depth of 1.4cm and a Source Axis Distance (SAD) of 100cm. A polynomial fit was applied to the calibration curve, in order to obtain the equation relating dose response with optical density. The spatial distribution is obtained in terms of percentage of the dose, placing 3×3cm samples of RCF on the acrylic screen, which is placed in front of the patient in order to obtain maximum absorbed dose on the skin, covering an area of 200×100cm{sup 2}. The Percentage Depth Dose (PDD) curve was obtained placing RCF samples at depths of 0, 1, 1.2, 1.4, 1.5, 2, 3, 4, 5, 6, 7, 8 and 9cm in the solid water phantom, irradiated with an ELEKTA SINERGY Linear Accelerator electron beam, with an energy of 6 MeV, at a Source Skin Distance (SSD) of 500cm, with 1000MU = 100Gy, with a cone of 40×40cm and gantry angle of 90°. The RCFs were scanned on a flatbed scanner (EPSON EXPRESSION 10000 XL) and the images were processed with the ImageJ program using a region of interest (ROI) of 1×1cm{sup 2}. Results: The relative spatial dose distribution and the percentage depth dose for a SSD of 500±0.5cm, over an area of 200×100cm{sup 2} was obtained, resulting to an effective maximum dose depth (Z{sub ref}) for electrons of 1.4±0.05cm. Using the same experimental data, horizontal and vertical beam profiles were also graphed, showing a horizontal symmetry of ±035%, horizontal flatness of ±3.62%, vertical symmetry of ±2.1% and vertical flatness of ±14.2%. Conclusions: The electron beam was characterized and the data obtained were useful to determine the spatial dose distribution to a SSD of 500±0.5cm, in an area of 200×100cm{sup 2}. Dose profiles were obtained both horizontally and vertically, thus allowing to assess electron beam symmetry and flatness. PDD analysis up to a depth of 9±0.05cm, has made possible to establish the depth of electron penetration, assuring an only skin irradiation treatment.« less
Tohidast, Parisa; Shi, Xie-Qi
2016-01-01
The objectives of this study were to present the subjective knowledge level and the use of image processing on digital intraoral radiographs amongst general dental practitioners at Distriktståndvrden AB, Stockholm. A questionnaire, consisting of12 questions, was sent to 12 dental prac- tices in Stockholm. Additionally, 2000 radiographs were randomly selected from these clinics for evaluation of applied image processing and its effect on image quality. Descriptive and analytical statistical methods were applied to present the current status of the use of image proces- sing alternatives for the dentists' daily clinical work. 50 out of 53 dentists participated in the survey.The survey showed that most of dentists in.this study had received education on image processing at some stage of their career. No correlations were found between application of image processing on one side and educa- tion received with regards to image processing, previous working experience, age and gender on the other. Image processing in terms of adjusting brightness and contrast was frequently used. Overall, in this study 24.5% of the 200 images were actually image processed in practice, in which 90% of the images were improved or maintained in image quality. According to our survey, image processing is experienced to be frequently used by the dentists at Distriktstandvåden AB for diagnosing anatomical and pathological changes using intraoral radiographs. 24.5% of the 200 images were actually image processed in terms of adjusting brightness and/or contrast. In the present study we did not found that the dentists' age, gender, previous working experience and education in image processing influence their viewpoint towards the application of image processing.
Quantum Image Processing and Its Application to Edge Detection: Theory and Experiment
NASA Astrophysics Data System (ADS)
Yao, Xi-Wei; Wang, Hengyan; Liao, Zeyang; Chen, Ming-Cheng; Pan, Jian; Li, Jun; Zhang, Kechao; Lin, Xingcheng; Wang, Zhehui; Luo, Zhihuang; Zheng, Wenqiang; Li, Jianzhong; Zhao, Meisheng; Peng, Xinhua; Suter, Dieter
2017-07-01
Processing of digital images is continuously gaining in volume and relevance, with concomitant demands on data storage, transmission, and processing power. Encoding the image information in quantum-mechanical systems instead of classical ones and replacing classical with quantum information processing may alleviate some of these challenges. By encoding and processing the image information in quantum-mechanical systems, we here demonstrate the framework of quantum image processing, where a pure quantum state encodes the image information: we encode the pixel values in the probability amplitudes and the pixel positions in the computational basis states. Our quantum image representation reduces the required number of qubits compared to existing implementations, and we present image processing algorithms that provide exponential speed-up over their classical counterparts. For the commonly used task of detecting the edge of an image, we propose and implement a quantum algorithm that completes the task with only one single-qubit operation, independent of the size of the image. This demonstrates the potential of quantum image processing for highly efficient image and video processing in the big data era.
Enabling Climate Science Investigations by Students Using Cryosphere Climate Data Records (CDRs)
NASA Astrophysics Data System (ADS)
Ledley, T. S.; Youngman, B.; Meier, W.; Bardar, E.
2010-12-01
The polar regions are particularly sensitive to changes in the climate system, and as such changes can be recognized there first. Scientists make use of this to help them develop and execute research programs that will deepen and expand our understanding of the climate system. However, the same cryosphere CDRs collected by scientists are a useful and reliable resource for helping students investigate and discover the manifestations and implications of global climate change. We have developed a number of avenues to facilitate the use of cryosphere CDRs in educational contexts. These include the Earth Exploration Toolbook (EET, http://serc.carleton.edu/eet), DataSheets (http://serc.carleton.edu/usingdata/browse_sheets.html), and Cryosphere-EarthLabs (http://serc.carleton.edu/dev/earthlabs/cryosphere). The EET is an online resource comprised of “chapters”, each of which focuses on a specific Earth science dataset and data analysis tool. Chapters provide step-by-step instructions for accessing the dataset and analysis tool, putting the data into the tool, and conducting an analysis around a specific scientific concept or issue. There are a number of EET chapters that utilize cryosphere CDRs. The EET chapter “Whither Arctic Sea Ice?” uses ~30 years of Arctic sea ice extent images and image processing software to study changes in sea ice extent. “Is Greenland Melting?” uses ice thickness data, ice melting extents and weather station data to examine the changes in the Greenland Ice Sheet. Other EET chapters that utilize cryosphere CDRs include “Using NASA NEO and ImageJ to Explore the Role of Snow Cover in Shaping Climate” and “Envisioning Climate Change Using a Global Climate Model.” In addition to creating these activities to facilitate the use of cryosphere CDRs we have also created DataSheets for these CDRs. DataSheets are educationally relevant human readable metadata about a dataset that provide both the scientific background information about the dataset as well as the topics and skills that can be taught using the dataset. DataSheets enable an educator to make effective use of a dataset outside the context of an educational activity. A DataSheet created for the sea ice index used in the “Whither Arctic Sea Ice? EET chapter is “Exploring Sea Ice Data From Satellites.” An EarthLabs module is a suite of 7-9 labs intended to be the laboratory component of a high-school capstone Earth and Space Science course. The Cryosphere-EarthLabs module focuses on sea ice to help students deepen their understanding of change over time in the climate system on multiple and embedded time scales. The module contains hands-on activities and investigations using online cryosphere CDRs to help students understand the how sea ice forms and varies, how the cryosphere changes, and the causes of those changes on time scales ranging from the seasonal to ice age time scales. In this presentation we will examine the EET and EarthLabs resources that help educators and students explore climate change using cryosphere CDRs; examine the DataSheets for these datasets; and describe how your cryosphere CDRs can be made available through these resources.
SU-E-T-96: Energy Dependence of the New GafChromic- EBT3 Film's Dose Response-Curve.
Chiu-Tsao, S; Massillon-Jl, G; Domingo-Muñoz, I; Chan, M
2012-06-01
To study and compare the dose response curves of the new GafChromic EBT3 film for megavoltage and kilovoltage x-ray beams, with different spatial resolution. Two sets of EBT3 films (lot#A101711-02) were exposed to each x-ray beam (6MV, 15MV and 50kV) at 8 dose values (50-3200cGy). The megavoltage beams were calibrated per AAPM TG-51 protocol while the kilovoltage beam was calibrated following the TG-61 using an ionization chamber calibrated at NIST. Each film piece was scanned three consecutive times in the center of Epson 10000XL flatbed scanner in transmission mode, landscape orientation, 48-bit color at two separate spatial resolutions of 75 and 300 dpi. The data were analyzed using ImageJ and, for each scanned image, a region of interest (ROI) of 2×2cm 2 at the field center was selected to obtain the mean pixel value with its standard deviation in the ROI. For each energy, dose value and spatial resolution, the average netOD and its associated uncertainty were determined. The Student's t-test was performed to evaluate the statistical differences between the netOD/dose values of the three energy modalities, with different color channels and spatial resolutions. The dose response curves for the three energy modalities were compared in three color channels with 75 and 300dpi. Weak energy dependence was found. For doses above 100cGy, no statistical differences were observed between 6 and 15MV beams, regardless of spatial resolution. However, statistical differences were observed between 50kV and the megavoltage beams. The degree of energy dependence (from MV to 50kV) was found to be function of color channel, dose level and spatial resolution. The dose response curves for GafChromic EBT3 films were found to be weakly dependent on the energy of the photon beams from 6MV to 50kV. The degree of energy dependence varies with color channel, dose and spatial resolution. GafChromic EBT3 films were supplied by Ashland Corp. This work was partially supported by DGAPA-UNAM grant IN102610 and Conacyt Mexico grant 127409. © 2012 American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
Tyapkina, Oksana; Islamov, Rustem; Nurullin, Leniz; Petrov, Konstantin.; Rezvyakov, Pavel; Nikolsky, Evgeny
To investigate mechanisms of hypogravity motor syndrome development the immunoexpression of heat shock proteins (Hsp27 and Hsp70), proteins of synaptic transmission (Synaptophysin and PSD95) and neuroprotective proteins (VEGF and Flt-1) in motoneurons of lumbar spinal cord in c57black/6 control mice (n=2) and after 30-days space flight (n=2) was studied. For a quantitative assessment of target proteins level in motoneurons frozen cross sections of lumbar spinal cord were underwent to immunohistochemical staining. Primary antibodies against VEGF, Flt-1, Hsp27 and Hsp70 (SantaCruz Biotechnology, inc. USA), against Synaptophysin and PSD95 (Abcam plc, UK) were visualized by streptavidin-biotin method. Images of spinal cords were received using OlympusBX51WI microscope with AxioCamMRm camera (CarlZeiss, Germany) and the AxioVisionRel. 4.6.3 software (CarlZeiss, Germany). The digitized data were analyzed using ImageJ 1.43 software (NIH, the USA). Quantitively, protein level in motoneurons was estimated by the density of immunoprecipitation. Results of research have not revealed any reliable changes in the immunnoexpression of vascular endothelial growth factor (VEGF) and its Flt-1 receptor in motoneurons of lumbar spinal cord in control and in mice after 30-day space flight. Studying of heat shock proteins, such as Hsp27 and Hsp70, revealed the decrease in level of these proteins immunoexpression in motoneurons of mice from flight group by 15% and 10%, respectively. Some decrease in level of immunnoexpression of presynaptic membrane proteins (synaptophysin, by 21%) and proteins of postsynaptic area (PSD95, by 55%) was observed after space flight. The data obtained testify to possible changes in a functional state (synaptic activity and stress resistance) of motoneurons of lumbar spinal cord in mice after space flight. Thus, we obtained new data on involvement of motoneurons innervating skeletal muscles in development of hypogravity motor syndrome. Research was supported by grants of: BION-M1, program of the President of the Russian Federation (Science School) no. No. 5584.214.4 (NEE), RFFR No.11-04-00602 (NEE), Program No.7 of Presidium of RAS (NEE), RFFR No.13-04-00310 (IRR), RFFR No.12-04-01414 (NLF).
The effect of impression volume and double-arch trays on the registration of maximum intercuspation.
Hahn, Sara M; Millstein, Philip L; Kinnunen, Taru H; Wright, Robert F
2009-12-01
The type of double-arch trays used may affect occlusion. The purpose of this study was to determine what effect, if any, double-arch tray design and impression material volume had on the registration of maximum intercuspation (MI). Quadrant impressions were made on articulated fracture-resistant dental casts mounted in maximum intercuspation occlusion. Three types of sideless double-arch impression trays were used: First Bite with nylon webbing, Sultan's 3-Way with double crosshatch webbing, and Premium's 3-in-1 Tray with single crosshatch webbing. Vinyl polysiloxane impression material (Aquasil Ultra Rigid Fast Set) was distributed at 2 different volumes (5.4 ml and 8.3 ml), and 60 impressions were made (n=10). A weight of 1.2 kg was placed on the upper arm of an Artex articulator, ensuring complete closure. The impressions were allowed to polymerize for 5 minutes. After polymerization, specimens were placed on a light box, and a camera set at a fixed distance was used to capture the light transmission that was projected through the impression material. The camera transferred the information to an image analysis program (ImageJ). This system allowed the different amounts of light projected through the impression to be translated into a gray scale value (GSV), which was assigned a thickness value, in millimeters, of a specified occlusal contact area. To assess reliability of the experimental design, 10 control impressions were made by directly applying impression material onto the typodont. These were analyzed in the same manner as the impressions made with trays. A 2-way ANOVA comparing volume by tray type was used (alpha=.05). This was followed by a Tukey HSD test. There was no main effect for volume of impression material (P=.71). Tray type was significantly different (P<.001). Impressions made with Sultan trays were significantly less accurate than impressions made with First Bite or Premium impression trays. The Premium tray type had the highest mean (SD) GSV, 179.8 (8.1), significantly higher than First Bite (164.7 (19.8); P<.001) or Sultan (82.8 (7.4); P<.001) trays. This in vitro study demonstrated that certain trays hinder closure into MI, which may negatively affect the accuracy of record making.
Transplant Image Processing Technology under Windows into the Platform Based on MiniGUI
NASA Astrophysics Data System (ADS)
Gan, Lan; Zhang, Xu; Lv, Wenya; Yu, Jia
MFC has a large number of digital image processing-related API functions, object-oriented and class mechanisms which provides image processing technology strong support in Windows. But in embedded systems, image processing technology dues to the restrictions of hardware and software do not have the environment of MFC in Windows. Therefore, this paper draws on the experience of image processing technology of Windows and transplants it into MiniGUI embedded systems. The results show that MiniGUI/Embedded graphical user interface applications about image processing which used in embedded image processing system can be good results.
The Goddard Space Flight Center Program to develop parallel image processing systems
NASA Technical Reports Server (NTRS)
Schaefer, D. H.
1972-01-01
Parallel image processing which is defined as image processing where all points of an image are operated upon simultaneously is discussed. Coherent optical, noncoherent optical, and electronic methods are considered parallel image processing techniques.
Multiscale image processing and antiscatter grids in digital radiography.
Lo, Winnie Y; Hornof, William J; Zwingenberger, Allison L; Robertson, Ian D
2009-01-01
Scatter radiation is a source of noise and results in decreased signal-to-noise ratio and thus decreased image quality in digital radiography. We determined subjectively whether a digitally processed image made without a grid would be of similar quality to an image made with a grid but without image processing. Additionally the effects of exposure dose and of a using a grid with digital radiography on overall image quality were studied. Thoracic and abdominal radiographs of five dogs of various sizes were made. Four acquisition techniques were included (1) with a grid, standard exposure dose, digital image processing; (2) without a grid, standard exposure dose, digital image processing; (3) without a grid, half the exposure dose, digital image processing; and (4) with a grid, standard exposure dose, no digital image processing (to mimic a film-screen radiograph). Full-size radiographs as well as magnified images of specific anatomic regions were generated. Nine reviewers rated the overall image quality subjectively using a five-point scale. All digitally processed radiographs had higher overall scores than nondigitally processed radiographs regardless of patient size, exposure dose, or use of a grid. The images made at half the exposure dose had a slightly lower quality than those made at full dose, but this was only statistically significant in magnified images. Using a grid with digital image processing led to a slight but statistically significant increase in overall quality when compared with digitally processed images made without a grid but whether this increase in quality is clinically significant is unknown.
Developing image processing meta-algorithms with data mining of multiple metrics.
Leung, Kelvin; Cunha, Alexandre; Toga, A W; Parker, D Stott
2014-01-01
People often use multiple metrics in image processing, but here we take a novel approach of mining the values of batteries of metrics on image processing results. We present a case for extending image processing methods to incorporate automated mining of multiple image metric values. Here by a metric we mean any image similarity or distance measure, and in this paper we consider intensity-based and statistical image measures and focus on registration as an image processing problem. We show how it is possible to develop meta-algorithms that evaluate different image processing results with a number of different metrics and mine the results in an automated fashion so as to select the best results. We show that the mining of multiple metrics offers a variety of potential benefits for many image processing problems, including improved robustness and validation.
Image processing and products for the Magellan mission to Venus
NASA Technical Reports Server (NTRS)
Clark, Jerry; Alexander, Doug; Andres, Paul; Lewicki, Scott; Mcauley, Myche
1992-01-01
The Magellan mission to Venus is providing planetary scientists with massive amounts of new data about the surface geology of Venus. Digital image processing is an integral part of the ground data system that provides data products to the investigators. The mosaicking of synthetic aperture radar (SAR) image data from the spacecraft is being performed at JPL's Multimission Image Processing Laboratory (MIPL). MIPL hosts and supports the Image Data Processing Subsystem (IDPS), which was developed in a VAXcluster environment of hardware and software that includes optical disk jukeboxes and the TAE-VICAR (Transportable Applications Executive-Video Image Communication and Retrieval) system. The IDPS is being used by processing analysts of the Image Data Processing Team to produce the Magellan image data products. Various aspects of the image processing procedure are discussed.
Image Processing Using a Parallel Architecture.
1987-12-01
ENG/87D-25 Abstract This study developed a set o± low level image processing tools on a parallel computer that allows concurrent processing of images...environment, the set of tools offers a significant reduction in the time required to perform some commonly used image processing operations. vI IMAGE...step toward developing these systems, a structured set of image processing tools was implemented using a parallel computer. More important than
Developing Image Processing Meta-Algorithms with Data Mining of Multiple Metrics
Cunha, Alexandre; Toga, A. W.; Parker, D. Stott
2014-01-01
People often use multiple metrics in image processing, but here we take a novel approach of mining the values of batteries of metrics on image processing results. We present a case for extending image processing methods to incorporate automated mining of multiple image metric values. Here by a metric we mean any image similarity or distance measure, and in this paper we consider intensity-based and statistical image measures and focus on registration as an image processing problem. We show how it is possible to develop meta-algorithms that evaluate different image processing results with a number of different metrics and mine the results in an automated fashion so as to select the best results. We show that the mining of multiple metrics offers a variety of potential benefits for many image processing problems, including improved robustness and validation. PMID:24653748
MOPEX: a software package for astronomical image processing and visualization
NASA Astrophysics Data System (ADS)
Makovoz, David; Roby, Trey; Khan, Iffat; Booth, Hartley
2006-06-01
We present MOPEX - a software package for astronomical image processing and display. The package is a combination of command-line driven image processing software written in C/C++ with a Java-based GUI. The main image processing capabilities include creating mosaic images, image registration, background matching, point source extraction, as well as a number of minor image processing tasks. The combination of the image processing and display capabilities allows for much more intuitive and efficient way of performing image processing. The GUI allows for the control over the image processing and display to be closely intertwined. Parameter setting, validation, and specific processing options are entered by the user through a set of intuitive dialog boxes. Visualization feeds back into further processing by providing a prompt feedback of the processing results. The GUI also allows for further analysis by accessing and displaying data from existing image and catalog servers using a virtual observatory approach. Even though originally designed for the Spitzer Space Telescope mission, a lot of functionalities are of general usefulness and can be used for working with existing astronomical data and for new missions. The software used in the package has undergone intensive testing and benefited greatly from effective software reuse. The visualization part has been used for observation planning for both the Spitzer and Herschel Space Telescopes as part the tool Spot. The visualization capabilities of Spot have been enhanced and integrated with the image processing functionality of the command-line driven MOPEX. The image processing software is used in the Spitzer automated pipeline processing, which has been in operation for nearly 3 years. The image processing capabilities have also been tested in off-line processing by numerous astronomers at various institutions around the world. The package is multi-platform and includes automatic update capabilities. The software package has been developed by a small group of software developers and scientists at the Spitzer Science Center. It is available for distribution at the Spitzer Science Center web page.
NASA Astrophysics Data System (ADS)
Maragos, Petros
The topics discussed at the conference include hierarchical image coding, motion analysis, feature extraction and image restoration, video coding, and morphological and related nonlinear filtering. Attention is also given to vector quantization, morphological image processing, fractals and wavelets, architectures for image and video processing, image segmentation, biomedical image processing, and model-based analysis. Papers are presented on affine models for motion and shape recovery, filters for directly detecting surface orientation in an image, tracking of unresolved targets in infrared imagery using a projection-based method, adaptive-neighborhood image processing, and regularized multichannel restoration of color images using cross-validation. (For individual items see A93-20945 to A93-20951)
Markov Processes in Image Processing
NASA Astrophysics Data System (ADS)
Petrov, E. P.; Kharina, N. L.
2018-05-01
Digital images are used as an information carrier in different sciences and technologies. The aspiration to increase the number of bits in the image pixels for the purpose of obtaining more information is observed. In the paper, some methods of compression and contour detection on the basis of two-dimensional Markov chain are offered. Increasing the number of bits on the image pixels will allow one to allocate fine object details more precisely, but it significantly complicates image processing. The methods of image processing do not concede by the efficiency to well-known analogues, but surpass them in processing speed. An image is separated into binary images, and processing is carried out in parallel with each without an increase in speed, when increasing the number of bits on the image pixels. One more advantage of methods is the low consumption of energy resources. Only logical procedures are used and there are no computing operations. The methods can be useful in processing images of any class and assignment in processing systems with a limited time and energy resources.