A fast non-contact imaging photoplethysmography method using a tissue-like model
NASA Astrophysics Data System (ADS)
McDuff, Daniel J.; Blackford, Ethan B.; Estepp, Justin R.; Nishidate, Izumi
2018-02-01
Imaging photoplethysmography (iPPG) allows non-contact, concomitant measurement and visualization of peripheral blood flow using just an RGB camera. Most iPPG methods require a window of temporal data and complex computation, this makes real-time measurement and spatial visualization impossible. We present a fast,"window-less", non-contact imaging photoplethysmography method, based on a tissue-like model of the skin, that allows accurate measurement of heart rate and heart rate variability parameters. The error in heart rate estimates is equivalent to state-of-the-art techniques and computation is much faster.
NASA Astrophysics Data System (ADS)
Sun, Yu; Hu, Sijung; Azorin-Peris, Vicente; Greenwald, Stephen; Chambers, Jonathon; Zhu, Yisheng
2011-07-01
With the advance of computer and photonics technology, imaging photoplethysmography [(PPG), iPPG] can provide comfortable and comprehensive assessment over a wide range of anatomical locations. However, motion artifact is a major drawback in current iPPG systems, particularly in the context of clinical assessment. To overcome this issue, a new artifact-reduction method consisting of planar motion compensation and blind source separation is introduced in this study. The performance of the iPPG system was evaluated through the measurement of cardiac pulse in the hand from 12 subjects before and after 5 min of cycling exercise. Also, a 12-min continuous recording protocol consisting of repeated exercises was taken from a single volunteer. The physiological parameters (i.e., heart rate, respiration rate), derived from the images captured by the iPPG system, exhibit functional characteristics comparable to conventional contact PPG sensors. Continuous recordings from the iPPG system reveal that heart and respiration rates can be successfully tracked with the artifact reduction method even in high-intensity physical exercise situations. The outcome from this study thereby leads to a new avenue for noncontact sensing of vital signs and remote physiological assessment, with clear applications in triage and sports training.
NASA Astrophysics Data System (ADS)
Marcinkevics, Zbignevs; Rubins, Uldis; Zaharans, Janis; Miscuks, Aleksejs; Urtane, Evelina; Ozolina-Moll, Liga
2016-03-01
The feasibility of bispectral imaging photoplethysmography (iPPG) system for clinical assessment of cutaneous microcirculation at two different depths is proposed. The iPPG system has been developed and evaluated for in vivo conditions during various tests: (1) topical application of vasodilatory liniment on the skin, (2) skin local heating, (3) arterial occlusion, and (4) regional anesthesia. The device has been validated by the measurements of a laser Doppler imager (LDI) as a reference. The hardware comprises four bispectral light sources (530 and 810 nm) for uniform illumination of skin, video camera, and the control unit for triggering of the system. The PPG signals were calculated and the changes of perfusion index (PI) were obtained during the tests. The results showed convincing correlations for PI obtained by iPPG and LDI at (1) topical liniment (r=0.98) and (2) heating (r=0.98) tests. The topical liniment and local heating tests revealed good selectivity of the system for superficial microcirculation monitoring. It is confirmed that the iPPG system could be used for assessment of cutaneous perfusion at two different depths, morphologically and functionally different vascular networks, and thus utilized in clinics as a cost-effective alternative to the LDI.
Marcinkevics, Zbignevs; Rubins, Uldis; Zaharans, Janis; Miscuks, Aleksejs; Urtane, Evelina; Ozolina-Moll, Liga
2016-03-01
The feasibility of bispectral imaging photoplethysmography (iPPG) system for clinical assessment of cutaneous microcirculation at two different depths is proposed. The iPPG system has been developed and evaluated for in vivo conditions during various tests: (1) topical application of vasodilatory liniment on the skin, (2) skin local heating, (3) arterial occlusion, and (4) regional anesthesia. The device has been validated by the measurements of a laser Doppler imager (LDI) as a reference. The hardware comprises four bispectral light sources (530 and 810 nm) for uniform illumination of skin, video camera, and the control unit for triggering of the system. The PPG signals were calculated and the changes of perfusion index (PI) were obtained during the tests. The results showed convincing correlations for PI obtained by iPPG530 nm and LDI at (1) topical liniment (r = 0.98) and (2) heating (r = 0.98) tests. The topical liniment and local heating tests revealed good selectivity of the system for superficial microcirculation monitoring. It is confirmed that the iPPG system could be used for assessment of cutaneous perfusion at two different depths, morphologically and functionally different vascular networks, and thus utilized in clinics as a cost-effective alternative to the LDI.
Photoplethysmography revisited: from contact to noncontact, from point to imaging ♠
Thakor, Nitish
2016-01-01
Photoplethysmography (PPG) is a non-invasive optical technique for detecting microvascular blood volume changes in tissues. Its ease of use, low cost and convenience make it an attractive area of research in the biomedical and clinical communities. Nevertheless, its single spot monitoring and the need to apply a PPG sensor directly to the skin limit its practicality in situations such as perfusion mapping and healing assessments or when free movement is required. The introduction of fast digital cameras into clinical imaging monitoring and diagnosis systems, the desire to reduce the physical restrictions, and the possible new insights that might come from perfusion imaging and mapping inspired the evolution of conventional PPG technology to imaging PPG (IPPG). IPPG is a noncontact method that can detect heart-generated pulse waves by means of peripheral blood perfusion measurements. Since its inception, IPPG has attracted significant public interest and provided opportunities to improve personal healthcare. This study presents an overview of the wide range of IPPG systems currently being introduced along with examples of their application in various physiological assessments. We believe that the widespread acceptance of IPPG is happening, and it will dramatically accelerate the promotion of this healthcare model in the near future. PMID:26390439
A contact-force regulated photoplethysmography (PPG) platform
NASA Astrophysics Data System (ADS)
Sim, Jai Kyoung; Ahn, Bongyoung; Doh, Il
2018-04-01
A photoplethysmography (PPG) platform integrated with a miniaturized force-regulator is proposed in this study. Because a thermo-pneumatic type regulator maintains a consistent contact-force between the PPG probe and the measuring site, a consistent and stable PPG signal can be obtained. We designed and fabricated a watch-type PPG platform with an overall size of 35 mm × 19 mm. In the PPG measurement on the radial artery wrist while posture of the wrist is changed to extension, neutral, or flexion, regulation of the contact-force provides consistent PPG measurements for which the variations in the PPG amplitude (PPGA) was 7.2 %. The proposed PPG platform can be applied to biosignal measurements in various fields such as PPG-based ANS monitoring to estimate nociception, sleep apnea syndrome, and psychological stress.
Motion robust remote photoplethysmography in CIELab color space
NASA Astrophysics Data System (ADS)
Yang, Yuting; Liu, Chenbin; Yu, Hui; Shao, Dangdang; Tsow, Francis; Tao, Nongjian
2016-11-01
Remote photoplethysmography (rPPG) is attractive for tracking a subject's physiological parameters without wearing a device. However, rPPG is known to be prone to body movement-induced artifacts, making it unreliable in realistic situations. Here we report a method to minimize the movement-induced artifacts. The method selects an optimal region of interest (ROI) automatically, prunes frames in which the ROI is not clearly captured (e.g., subject moves out of the view), and analyzes rPPG using an algorithm in CIELab color space, rather than the widely used RGB color space. We show that body movement primarily affects image intensity, rather than chromaticity, and separating chromaticity from intensity in CIELab color space thus helps achieve effective reduction of the movement-induced artifacts. We validate the method by performing a pilot study including 17 people with diverse skin tones.
Comparison of scientific CMOS camera and webcam for monitoring cardiac pulse after exercise
NASA Astrophysics Data System (ADS)
Sun, Yu; Papin, Charlotte; Azorin-Peris, Vicente; Kalawsky, Roy; Greenwald, Stephen; Hu, Sijung
2011-09-01
In light of its capacity for remote physiological assessment over a wide range of anatomical locations, imaging photoplethysmography has become an attractive research area in biomedical and clinical community. Amongst recent iPPG studies, two separate research directions have been revealed, i.e., scientific camera based imaging PPG (iPPG) and webcam based imaging PPG (wPPG). Little is known about the difference between these two techniques. To address this issue, a dual-channel imaging PPG system (iPPG and wPPG) using ambient light as the illumination source has been introduced in this study. The performance of the two imaging PPG techniques was evaluated through the measurement of cardiac pulse acquired from the face of 10 male subjects before and after 10 min of cycling exercise. A time-frequency representation method was used to visualize the time-dependent behaviour of the heart rate. In comparison to the gold standard contact PPG, both imaging PPG techniques exhibit comparable functional characteristics in the context of cardiac pulse assessment. Moreover, the synchronized ambient light intensity recordings in the present study can provide additional information for appraising the performance of the imaging PPG systems. This feasibility study thereby leads to a new route for non-contact monitoring of vital signs, with clear applications in triage and homecare.
Motion robust remote photoplethysmography in CIELab color space
Yang, Yuting; Liu, Chenbin; Yu, Hui; Shao, Dangdang; Tsow, Francis; Tao, Nongjian
2016-01-01
Abstract. Remote photoplethysmography (rPPG) is attractive for tracking a subject’s physiological parameters without wearing a device. However, rPPG is known to be prone to body movement-induced artifacts, making it unreliable in realistic situations. Here we report a method to minimize the movement-induced artifacts. The method selects an optimal region of interest (ROI) automatically, prunes frames in which the ROI is not clearly captured (e.g., subject moves out of the view), and analyzes rPPG using an algorithm in CIELab color space, rather than the widely used RGB color space. We show that body movement primarily affects image intensity, rather than chromaticity, and separating chromaticity from intensity in CIELab color space thus helps achieve effective reduction of the movement-induced artifacts. We validate the method by performing a pilot study including 17 people with diverse skin tones. PMID:27812695
NASA Astrophysics Data System (ADS)
Amelard, Robert; Scharfenberger, Christian; Wong, Alexander; Clausi, David A.
2015-03-01
Non-contact camera-based imaging photoplethysmography (iPPG) is useful for measuring heart rate in conditions where contact devices are problematic due to issues such as mobility, comfort, and sanitation. Existing iPPG methods analyse the light-tissue interaction of either active or passive (ambient) illumination. Many active iPPG methods assume the incident ambient light is negligible to the active illumination, resulting in high power requirements, while many passive iPPG methods assume near-constant ambient conditions. These assumptions can only be achieved in environments with controlled illumination and thus constrain the use of such devices. To increase the number of possible applications of iPPG devices, we propose a dual-mode active iPPG system that is robust to changes in ambient illumination variations. Our system uses a temporally-coded illumination sequence that is synchronized with the camera to measure both active and ambient illumination interaction for determining heart rate. By subtracting the ambient contribution, the remaining illumination data can be attributed to the controlled illuminant. Our device comprises a camera and an LED illuminant controlled by a microcontroller. The microcontroller drives the temporal code via synchronizing the frame captures and illumination time at the hardware level. By simulating changes in ambient light conditions, experimental results show our device is able to assess heart rate accurately in challenging lighting conditions. By varying the temporal code, we demonstrate the trade-off between camera frame rate and ambient light compensation for optimal blood pulse detection.
Analyzing the value of monitoring duodenal mucosal perfusion using photoplethysmography.
Fink, Mitchell P
2014-10-13
Photoplethysmography (PPG) is a technique that permits noninvasive measurement of changes in the volume of tissues. A novel device uses PPG to assess changes in duodenal mucosal perfusion. When tested in septic piglets, data obtained using this device correlate with the blood lactate concentration and duodenal serosal microvascular blood flow as measured with a laser Doppler flowmeter. This new PPG-based approach for continuously monitoring gut mucosal perfusion warrants further development, leading to prospective clinical trials in patients.
The assessment of sympathetic activity using iPPG based inter-limb coherence measurements
NASA Astrophysics Data System (ADS)
Tsoy, Maria O.; Rogatina, Kristina V.; Stiukhina, Elena S.; Postnov, Dmitry E.
2017-04-01
Photoplethysmography is an optical technique that can be used to detect blood volume changes and to measure important physiological parameters. This is low cost and non-invasive technique. However, one has to apply sensor directly to the skin. In this regard, the development on remote mothods receives the growing attention, such as imaging photoplethysmography (iPPG). Note, most of public-available iPPG systems are based on smartphone-embedded cameras, and thus have a sample frequency about 30-60 frames per second, which is enough for heart rate measurements, but may be too low for some more advanced usages of this technique. In our work, we describe the attempt to use smartphone-based iPPG technique aimed to measure the tiny mismatch in RR interval data series recorded from left and right arms. We use the transmission mode iPPG, in which the light transmitted through the medium of finger is detected by a web-camera opposite the LED source. The computational scheme by processing and analysis of the received signal was implemented using MATLAB language (MathWork Inc. in the United States). We believe that further development of our approach may lead to fast and low cost method to access the state of the sympathetic nervous system.
NASA Astrophysics Data System (ADS)
Thatcher, Jeffrey E.; Plant, Kevin D.; King, Darlene R.; Block, Kenneth L.; Fan, Wensheng; DiMaio, J. Michael
2014-05-01
Non-contact photoplethysmography (PPG) has been studied as a method to provide low-cost and non-invasive medical imaging for a variety of near-surface pathologies and two dimensional blood oxygenation measurements. Dynamic tissue phantoms were developed to evaluate this technology in a laboratory setting. The purpose of these phantoms was to generate a tissue model with tunable parameters including: blood vessel volume change; pulse wave frequency; and optical scattering and absorption parameters. A non-contact PPG imaging system was evaluated on this model and compared against laser Doppler imaging (LDI) and a traditional pulse oximeter. Results indicate non-contact PPG accurately identifies pulse frequency and appears to identify signals from optically dense phantoms with significantly higher detection thresholds than LDI.
Sun, Yu; Papin, Charlotte; Azorin-Peris, Vicente; Kalawsky, Roy; Greenwald, Stephen; Hu, Sijung
2012-03-01
Imaging photoplethysmography (PPG) is able to capture useful physiological data remotely from a wide range of anatomical locations. Recent imaging PPG studies have concentrated on two broad research directions involving either high-performance cameras and or webcam-based systems. However, little has been reported about the difference between these two techniques, particularly in terms of their performance under illumination with ambient light. We explore these two imaging PPG approaches through the simultaneous measurement of the cardiac pulse acquired from the face of 10 male subjects and the spectral characteristics of ambient light. Measurements are made before and after a period of cycling exercise. The physiological pulse waves extracted from both imaging PPG systems using the smoothed pseudo-Wigner-Ville distribution yield functional characteristics comparable to those acquired using gold standard contact PPG sensors. The influence of ambient light intensity on the physiological information is considered, where results reveal an independent relationship between the ambient light intensity and the normalized plethysmographic signals. This provides further support for imaging PPG as a means for practical noncontact physiological assessment with clear applications in several domains, including telemedicine and homecare. © 2012 Society of Photo-Optical Instrumentation Engineers (SPIE).
NASA Astrophysics Data System (ADS)
Sun, Yu; Papin, Charlotte; Azorin-Peris, Vicente; Kalawsky, Roy; Greenwald, Stephen; Hu, Sijung
2012-03-01
Imaging photoplethysmography (PPG) is able to capture useful physiological data remotely from a wide range of anatomical locations. Recent imaging PPG studies have concentrated on two broad research directions involving either high-performance cameras and or webcam-based systems. However, little has been reported about the difference between these two techniques, particularly in terms of their performance under illumination with ambient light. We explore these two imaging PPG approaches through the simultaneous measurement of the cardiac pulse acquired from the face of 10 male subjects and the spectral characteristics of ambient light. Measurements are made before and after a period of cycling exercise. The physiological pulse waves extracted from both imaging PPG systems using the smoothed pseudo-Wigner-Ville distribution yield functional characteristics comparable to those acquired using gold standard contact PPG sensors. The influence of ambient light intensity on the physiological information is considered, where results reveal an independent relationship between the ambient light intensity and the normalized plethysmographic signals. This provides further support for imaging PPG as a means for practical noncontact physiological assessment with clear applications in several domains, including telemedicine and homecare.
Assessing blood vessel perfusion and vital signs through retinal imaging photoplethysmography.
Hassan, Harnani; Jaidka, Sheila; Dwyer, Vincent M; Hu, Sijung
2018-05-01
One solution to the global challenge of increasing ocular disease is a cost-effective technique for rapid screening and assessment. Current ophthalmic imaging techniques, e.g. scanning and ocular blood flow systems, are expensive, complex to operate and utilize invasive contrast agents during assessment. The work presented here demonstrates a simple retinal imaging photoplethysmography (iPPG) system with the potential to provide screening, diagnosis, monitoring and assessment that is non-invasive, painless and radiationless. Time series of individual retinal blood vessel images, captured with an eye fundus camera, are processed using standard filtering, amplitude demodulation and principle component analysis (PCA) methods to determine the values of the heart rate (HR) and respiration rate (RR), which are in compliance with simultaneously obtained measurements using commercial pulse oximetry. It also seems possible that some information on the dynamic changes in oxygen saturation levels ( SpO 2 ) in a retinal blood vessel may also be obtained. As a consequence, the retinal iPPG modality system demonstrates a potential avenue for rapid ophthalmic screening, and even early diagnosis, against ocular disease without the need for fluorescent or contrast agents.
Remote photoplethysmography system for unsupervised monitoring regional anesthesia effectiveness
NASA Astrophysics Data System (ADS)
Rubins, U.; Miscuks, A.; Marcinkevics, Z.; Lange, M.
2017-12-01
Determining the level of regional anesthesia (RA) is vitally important to both an anesthesiologist and surgeon, also knowing the RA level can protect the patient and reduce the time of surgery. Normally to detect the level of RA, usually a simple subjective (sensitivity test) and complicated quantitative methods (thermography, neuromyography, etc.) are used, but there is not yet a standardized method for objective RA detection and evaluation. In this study, the advanced remote photoplethysmography imaging (rPPG) system for unsupervised monitoring of human palm RA is demonstrated. The rPPG system comprises compact video camera with green optical filter, surgical lamp as a light source and a computer with custom-developed software. The algorithm implemented in Matlab software recognizes the palm and two dermatomes (Medial and Ulnar innervation), calculates the perfusion map and perfusion changes in real-time to detect effect of RA. Seven patients (aged 18-80 years) undergoing hand surgery received peripheral nerve brachial plexus blocks during the measurements. Clinical experiments showed that our rPPG system is able to perform unsupervised monitoring of RA.
Advancements in remote physiological measurement and applications in human-computer interaction
NASA Astrophysics Data System (ADS)
McDuff, Daniel
2017-04-01
Physiological signals are important for tracking health and emotional states. Imaging photoplethysmography (iPPG) is a set of techniques for remotely recovering cardio-pulmonary signals from video of the human body. Advances in iPPG methods over the past decade combined with the ubiquity of digital cameras presents the possibility for many new, lowcost applications of physiological monitoring. This talk will highlight methods for recovering physiological signals, work characterizing the impact of video parameters and hardware on these measurements, and applications of this technology in human-computer interfaces.
Lee, Jihyoung; Matsumura, Kenta; Yamakoshi, Ken-ichi; Rolfe, Peter; Tanaka, Shinobu; Yamakoshi, Takehiro
2013-01-01
Reflection photoplethysmography (PPG) using 530 nm (green) wavelength light has the potential to be a superior method for monitoring heart rate (HR) during normal daily life due to its relative freedom from artifacts. However, little is known about the accuracy of pulse rate (PR) measured by 530 nm light PPG during motion. Therefore, we compared the HR measured by electrocadiography (ECG) as a reference with PR measured by 530, 645 (red), and 470 nm (blue) wavelength light PPG during baseline and while performing hand waving in 12 participants. In addition, we examined the change of signal-to-noise ratio (SNR) by motion for each of the three wavelengths used for the PPG. The results showed that the limit of agreement in Bland-Altman plots between the HR measured by ECG and PR measured by 530 nm light PPG (±0.61 bpm) was smaller than that achieved when using 645 and 470 nm light PPG (±3.20 bpm and ±2.23 bpm, respectively). The ΔSNR (the difference between baseline and task values) of 530 and 470nm light PPG was significantly smaller than ΔSNR for red light PPG. In conclusion, 530 nm light PPG could be a more suitable method than 645 and 470nm light PPG for monitoring HR in normal daily life.
Saliba Júnior, Orlando Adas; Giannini, Mariangela; Mórbio, Ana Paula; Saliba, Orlando; Rollo, Hamilton Almeida
2014-01-01
Objective. To evaluate the effectiveness of surgery in treating primary varicose veins in the lower limbs by photoplethysmography (PPG) and duplex mapping (DM). Method. Forty-eight lower limbs were clinically evaluated according to the CEAP classification system and subjected to PPG and DM exams. Each limb had a venous refill time (VRT) of <20 seconds and a normal deep vein system (DVS) by DM. Results. The mean pre- and postoperative VRTs were 13.79 and 26.43 seconds, respectively (P < 0.0001). After surgery, 42 limbs (87.50%) had normal results by PPG (VRT > 20 seconds). Four limbs (8.33%) showed improved VRTs, but the VRTs did not reach 20 seconds. In the 2 limbs (4.17%) that maintained their original VRTs, the DM exams showed the presence of insufficient perforating veins. Conclusion. In most cases, PPG allows for a satisfactory evaluation of the outcome of varicose vein surgery. PMID:24696783
Towards Photoplethysmography-Based Estimation of Instantaneous Heart Rate During Physical Activity.
Jarchi, Delaram; Casson, Alexander J
2017-09-01
Recently numerous methods have been proposed for estimating average heart rate using photoplethysmography (PPG) during physical activity, overcoming the significant interference that motion causes in PPG traces. We propose a new algorithm framework for extracting instantaneous heart rate from wearable PPG and Electrocardiogram (ECG) signals to provide an estimate of heart rate variability during exercise. For ECG signals, we propose a new spectral masking approach which modifies a particle filter tracking algorithm, and for PPG signals constrains the instantaneous frequency obtained from the Hilbert transform to a region of interest around a candidate heart rate measure. Performance is verified using accelerometry and wearable ECG and PPG data from subjects while biking and running on a treadmill. Instantaneous heart rate provides more information than average heart rate alone. The instantaneous heart rate can be extracted during motion to an accuracy of 1.75 beats per min (bpm) from PPG signals and 0.27 bpm from ECG signals. Estimates of instantaneous heart rate can now be generated from PPG signals during motion. These estimates can provide more information on the human body during exercise. Instantaneous heart rate provides a direct measure of vagal nerve and sympathetic nervous system activity and is of substantial use in a number of analyzes and applications. Previously it has not been possible to estimate instantaneous heart rate from wrist wearable PPG signals.
The advantages of wearable green reflected photoplethysmography.
Maeda, Yuka; Sekine, Masaki; Tamura, Toshiyo
2011-10-01
This report evaluates the efficacy of reflected-type green light photoplethysmography (green light PPG). Transmitted infrared light was used for PPG and the arterial pulse was monitored transcutaneously. The reflected PPG signal contains AC components based on the heartbeat-related signal from the arterial blood flow and DC components, which include reflectance and scattering from tissue. Generally, changes in AC components are monitored, but the DC components play an important role during heat stress. In this study, we compared the signal of green light PPG to infrared PPG and ECG during heat stress. The wavelengths of the green and infrared light were 525 nm and 880 nm, respectively. Experiments were performed on young healthy subjects in cold (10°C), hot (45°C), and normal environments. The pulse rates were compared among three measurement devices and the AC and DC components of the PPG signal were evaluated during heat stress. The pulse rates obtained from green light PPG were strongly correlated with the R-R interval of an electrocardiogram in all environments, but those obtained from infrared light PPG displayed a weaker correlation with cold exposure. The AC components were of similar signal output for both wavelengths during heat stress. Also, the DC components for green light PPG were similar during heat stress, but showed less signal output for infrared light PPG during hot exposure. The main reason for the reduced DC components was speculated to be the increased blood flow at the vascular bed. Therefore, reflected green light PPG can be useful for pulse rate monitoring because it is less influenced by the tissue and vein region.
NASA Astrophysics Data System (ADS)
Shvartsman, Leonid D.; Tverskoy, Boris
2015-03-01
We present system for long-term continuous PPG monitoring, and physical model for PPG analysis. The system is based on ideology of light scattering modulated by the process of RBC aggregation. OXIRATE's system works in reflection geometry. The sensor is tiny, completely mobile phone compatible, it can be placed nearly everywhere on the body surface. These technical features allow all-night comfortable PPG monitoring that was performed and analyzed. We can define various sleep stages on the basis of different reproducible time-behavior of PPG signal. Our system of PPG monitoring was used also for reflection pulse oximetry and for extreme PPG studies, such as diving.
Physical-mathematical model of optical radiation interaction with biological tissues
NASA Astrophysics Data System (ADS)
Kozlovska, Tetyana I.; Kolisnik, Peter F.; Zlepko, Sergey M.; Titova, Natalia V.; Pavlov, Volodymyr S.; Wójcik, Waldemar; Omiotek, Zbigniew; Kozhambardiyeva, Miergul; Zhanpeisova, Aizhan
2017-08-01
Remote photoplethysmography (PPG) imaging is an optical technique to remotely assess the local coetaneous microcirculation. In this paper, we present a model and supporting experiments confirming the contribution of skin inhomogeneity to the morphology of PPG waveforms. The physical-mathematical model of distribution of optical radiation in biological tissues was developed. It allows determining the change of intensity of optical radiation depending on such parameters as installation angle of the sensor, biological tissue thickness and the wavelength. We obtained graphics which represent changes of the optical radiation intensity that is registered by photodetector depending on installation angle of the sensor, biological tissue thickness and the extinction coefficient.
Rundo, Francesco; Ortis, Alessandro
2018-01-01
Physiological signals are widely used to perform medical assessment for monitoring an extensive range of pathologies, usually related to cardio-vascular diseases. Among these, both PhotoPlethysmoGraphy (PPG) and Electrocardiography (ECG) signals are those more employed. PPG signals are an emerging non-invasive measurement technique used to study blood volume pulsations through the detection and analysis of the back-scattered optical radiation coming from the skin. ECG is the process of recording the electrical activity of the heart over a period of time using electrodes placed on the skin. In the present paper we propose a physiological ECG/PPG “combo” pipeline using an innovative bio-inspired nonlinear system based on a reaction-diffusion mathematical model, implemented by means of the Cellular Neural Network (CNN) methodology, to filter PPG signal by assigning a recognition score to the waveforms in the time series. The resulting “clean” PPG signal exempts from distortion and artifacts is used to validate for diagnostic purpose an EGC signal simultaneously detected for a same patient. The multisite combo PPG-ECG system proposed in this work overpasses the limitations of the state of the art in this field providing a reliable system for assessing the above-mentioned physiological parameters and their monitoring over time for robust medical assessment. The proposed system has been validated and the results confirmed the robustness of the proposed approach. PMID:29385774
Rundo, Francesco; Conoci, Sabrina; Ortis, Alessandro; Battiato, Sebastiano
2018-01-30
Physiological signals are widely used to perform medical assessment for monitoring an extensive range of pathologies, usually related to cardio-vascular diseases. Among these, both PhotoPlethysmoGraphy (PPG) and Electrocardiography (ECG) signals are those more employed. PPG signals are an emerging non-invasive measurement technique used to study blood volume pulsations through the detection and analysis of the back-scattered optical radiation coming from the skin. ECG is the process of recording the electrical activity of the heart over a period of time using electrodes placed on the skin. In the present paper we propose a physiological ECG/PPG "combo" pipeline using an innovative bio-inspired nonlinear system based on a reaction-diffusion mathematical model, implemented by means of the Cellular Neural Network (CNN) methodology, to filter PPG signal by assigning a recognition score to the waveforms in the time series. The resulting "clean" PPG signal exempts from distortion and artifacts is used to validate for diagnostic purpose an EGC signal simultaneously detected for a same patient. The multisite combo PPG-ECG system proposed in this work overpasses the limitations of the state of the art in this field providing a reliable system for assessing the above-mentioned physiological parameters and their monitoring over time for robust medical assessment. The proposed system has been validated and the results confirmed the robustness of the proposed approach.
NASA Astrophysics Data System (ADS)
Mo, Weirong; Mohan, Rachit; Li, Weizhi; Zhang, Xu; Sellke, Eric W.; Fan, Wensheng; DiMaio, J. Michael; Thatcher, Jeffery E.
2015-02-01
We present a non-contact, reflective photoplethysmogram (PPG) imaging method and a prototype system for identifying the presence of dermal burn wounds during a burn debridement surgery. This system aims to provide assistance to clinicians and surgeons in the process of dermal wound management and wound triage decisions. We examined the system variables of illumination uniformity and intensity and present our findings. An LED array, a tungsten light source, and eventually high-power LED emitters were studied as illumination methods for our PPG imaging device. These three different illumination sources were tested in a controlled tissue phantom model and an animal burn model. We found that the low heat and even illumination pattern using high power LED emitters provided a substantial improvement to the collected PPG signal in our animal burn model. These improvements allow the PPG signal from different pixels to be comparable in both time-domain and frequency-domain, simplify the illumination subsystem complexity, and remove the necessity of using high dynamic range cameras. Through the burn model output comparison, such as the blood volume in animal burn data and controlled tissue phantom model, our optical improvements have led to more clinically applicable images to aid in burn assessment.
Wearable photoplethysmography device prototype for wireless cardiovascular monitoring
NASA Astrophysics Data System (ADS)
Kviesis-Kipge, E.; Grabovskis, A.; Marcinkevics, Z.; Mecnika, V.; Rubenis, O.
2014-05-01
The aim of the study was to develop a prototype system of the smart garment for real time telemetric monitoring of human cardiovascular activity. Two types of photoplethysmography (PPG) sensors for low noise and artefact free signal recording from various sites of the human body that were suitable for integration into smart textile were investigated. The reflectance sensors with single and multiple photodiodes based on "pulse-duration-based signal conversion" signal acquisition principle were designed and evaluated. The technical parameters of the system were measured both on bench and in vivo. Overall, both types of PPG sensors showed acceptable signal quality SNR 86.56±3.00 dB, dynamic range 89.84 dB. However, in-vivo condition tests revealed lower noise and higher accuracy achieved by applying the multiple photodiodes sensor. We concluded that the proposed PPG device prototype is simple and reliable, and therefore, can be utilized in low-cost smart garments.
NASA Astrophysics Data System (ADS)
Mizeva, Irina; Di Maria, Costanzo; Frick, Peter; Podtaev, Sergey; Allen, John
2015-03-01
Photoplethysmography (PPG) and laser Doppler flowmetry (LDF) are two recognized optical techniques that can track low-frequency perfusion changes in microcirculation. The aim of this study was to determine, in healthy subjects, the correlation between the techniques for specific low-frequency bands previously defined for microcirculation. Twelve healthy male subjects (age range 18 to 50 years) were studied, with PPG and LDF signals recorded for 20 min from their right and left index (PPG) and middle (LDF) fingers. Wavelet analysis comprised dividing the low-frequency integral wavelet spectrum (IWS) into five established physiological bands relating to cardiac, respiratory, myogenic, neurogenic, and endothelial activities. The correlation between PPG and LDF was quantified using wavelet correlation analysis and Spearman correlation analysis of the median IWS amplitude. The median wavelet correlation between signals (right-left side average) was 0.45 (cardiac), 0.49 (respiratory), 0.86 (myogenic), 0.91 (neurogenic), and 0.91 (endothelial). The correlation of IWS amplitude values (right-left side average) was statistically significant for the cardiac (ρ=0.64, p<0.05) and endothelial (ρ=0.62, p<0.05) bands. This pilot study has shown good correlation between PPG and LDF for specific physiological frequency bands. In particular, the results suggest that PPG has the potential to be a low-cost replacement for LDF for endothelial activity assessments.
A CMOS camera-based system for clinical photoplethysmographic applications
NASA Astrophysics Data System (ADS)
Humphreys, Kenneth; Markham, Charles; Ward, Tomas E.
2005-06-01
In this work an image-based photoplethysmography (PPG) system is developed and tested against a conventional finger-based system as commonly used in clinical practise. A PPG is essentially an optical instrument consisting of a near infrared (NIR) source and detector that is capable of tracking blood flow changes in body tissue. When used with a number of wavelengths in the NIR band blood oxygenation changes as well as other blood chemical signatures can be ascertained yielding a very useful device in the clinical realm. Conventionally such a device requires direct contact with the tissue under investigation which eliminates the possibility of its use for applications like wound management where the tissue oxygenation measurement could be extremely useful. To circumnavigate this shortcoming we have developed a CMOS camera-based system, which can successfully extract the PPG signal without contact with the tissue under investigation. A comparison of our results with conventional techniques has yielded excellent results.
Ye, Yalan; He, Wenwen; Cheng, Yunfei; Huang, Wenxia; Zhang, Zhilin
2017-02-16
The estimation of heart rate (HR) based on wearable devices is of interest in fitness. Photoplethysmography (PPG) is a promising approach to estimate HR due to low cost; however, it is easily corrupted by motion artifacts (MA). In this work, a robust approach based on random forest is proposed for accurately estimating HR from the photoplethysmography signal contaminated by intense motion artifacts, consisting of two stages. Stage 1 proposes a hybrid method to effectively remove MA with a low computation complexity, where two MA removal algorithms are combined by an accurate binary decision algorithm whose aim is to decide whether or not to adopt the second MA removal algorithm. Stage 2 proposes a random forest-based spectral peak-tracking algorithm, whose aim is to locate the spectral peak corresponding to HR, formulating the problem of spectral peak tracking into a pattern classification problem. Experiments on the PPG datasets including 22 subjects used in the 2015 IEEE Signal Processing Cup showed that the proposed approach achieved the average absolute error of 1.65 beats per minute (BPM) on the 22 PPG datasets. Compared to state-of-the-art approaches, the proposed approach has better accuracy and robustness to intense motion artifacts, indicating its potential use in wearable sensors for health monitoring and fitness tracking.
Abay, T Y; Kyriacou, P A
2016-04-01
Monitoring changes in blood volume, blood flow, and oxygenation in tissues is of vital importance in fields such as reconstructive surgery and trauma medicine. Near infrared spectroscopy (NIRS), laser Doppler (LDF) flowmetry, photoplethysmography (PPG), and pulse oximetry (PO) contribute to such fields due to their safe and noninvasive nature. However, the techniques have been rarely investigated simultaneously or altogether. The aim of this study was to investigate all the techniques simultaneously on healthy subjects during vascular occlusion challenges. Sensors were attached on the forearm (NIRS and LDF) and fingers (PPG and PO) of 19 healthy volunteers. Different degrees of vascular occlusion were induced by inflating a pressure cuff on the upper arm. The responses of tissue oxygenation index (NIRS), tissue haemoglobin index (NIRS), flux (LDF), perfusion index (PPG), and arterial oxygen saturation (PO) have been recorded and analyzed. Moreover, the optical densities were calculated from slow varying dc PPG, in order to distinguish changes in venous blood volumes. The indexes showed significant changes (p < 0.05) in almost all occlusions, either venous or over-systolic occlusions. However, differentiation between venous and arterial occlusion by LDF may be challenging and the perfusion index (PI) may not be adequate to indicate venous occlusions. Optical densities may be an additional tool to detect venous occlusions by PPG.
2013-02-11
PPG) is measuring this size using light. A particular and ubiquitous application of PPG is in pulse oximetry, whereby the oxygenation saturation of...arterial blood is measured. Pulse oximetry requires absorption measurements of oxygenated (HbO2) and deoxygenated hemoglobin (Hb) at 940 nm (near-IR...relative quantity of Hb to HbO2 (i.e., SpO2) may be determined noninvasively. The advent of such a noninvasive arterial oxygen saturation measurement was a
NASA Astrophysics Data System (ADS)
Laurent, Claes; Jonsson, Bjorn; Vegfors, Magnus; Eneling, Martin; Lindberg, Lars-Goran
2004-07-01
A soft (silicone) probe, containing six light emitting diodes (880 nm) and three photo detectors, utilizes photoplethysmography (PPG) to monitor pulsations from the brachialis artery under an occluding cuff during deflation. When the arterial pulse returns, measured by PPG, the corresponding pressure in the cuff is determined. This pressure is assumed to equal the systolic pressure. An assessment trial was performed on 21 patients (9 women and 12 men, aged 27-69) at the Neuro-Intensive care unit. Since the patients were already provided with arterial needles, invasive blood pressure could be used as the reference. By choosing a threshold, for detecting pulses, as a fraction (4%) of the maximum amplitude, the systolic blood pressure was underestimated (-0.57 mmHg, SD 12.1). The range of systolic pressure for the patients was 95.5 - 199.0 mmHg, n=14. The method is promising, but improvements still have to be made in order to improve the technique.
High-resolution motion-compensated imaging photoplethysmography for remote heart rate monitoring
NASA Astrophysics Data System (ADS)
Chung, Audrey; Wang, Xiao Yu; Amelard, Robert; Scharfenberger, Christian; Leong, Joanne; Kulinski, Jan; Wong, Alexander; Clausi, David A.
2015-03-01
We present a novel non-contact photoplethysmographic (PPG) imaging system based on high-resolution video recordings of ambient reflectance of human bodies that compensates for body motion and takes advantage of skin erythema fluctuations to improve measurement reliability for the purpose of remote heart rate monitoring. A single measurement location for recording the ambient reflectance is automatically identified on an individual, and the motion for the location is determined over time via measurement location tracking. Based on the determined motion information motion-compensated reflectance measurements at different wavelengths for the measurement location can be acquired, thus providing more reliable measurements for the same location on the human over time. The reflectance measurement is used to determine skin erythema fluctuations over time, resulting in the capture of a PPG signal with a high signal-to-noise ratio. To test the efficacy of the proposed system, a set of experiments involving human motion in a front-facing position were performed under natural ambient light. The experimental results demonstrated that skin erythema fluctuations can achieve noticeably improved average accuracy in heart rate measurement when compared to previously proposed non-contact PPG imaging systems.
NASA Astrophysics Data System (ADS)
Blackford, Ethan B.; Estepp, Justin R.; McDuff, Daniel J.
2018-02-01
Imaging photoplethysmography uses camera image sensors to measure variations in light absorption related to the delivery of the blood volume pulse to peripheral tissues. The characteristics of the measured BVP waveform depends on the spectral absorption of various tissue components including melanin, hemoglobin, water, and yellow pigments. Signal quality and artifact rejection can be enhanced by taking into account the spectral properties of the BVP waveform and surrounding tissue. The current literature regarding the spectral relationships of remote PPG is limited. To supplement this fundamental data, we present an analysis of remotely-measured, visible and near-infrared spectroscopy to better understand the spectral signature of remotely measured BVP signals. To do so, spectra were measured from the right cheek of 25, stationary participants whose heads were stabilized by a chinrest. A collimating lens was used to collect reflected light from a region of 3 cm in diameter. The spectrometer provided 3 nm resolution measurements from 500-1000 nm. Measurements were acquired at a rate of 50 complete spectra per second for a period of five minutes. Reference physiology, including electrocardiography was simultaneously and synchronously acquired. The spectral data were analyzed to determine the relationship between light wavelength and the resulting remote-BVP signal-to-noise ratio and to identify those bands best suited for pulse rate measurement. To our knowledge this is the most comprehensive dataset of remotely-measured spectral iPPG data. In due course, we plan to release this dataset for research purposes.
Smart Garment Fabrics to Enable Non-Contact Opto-Physiological Monitoring.
Iakovlev, Dmitry; Hu, Sijung; Hassan, Harnani; Dwyer, Vincent; Ashayer-Soltani, Roya; Hunt, Chris; Shen, Jinsong
2018-03-29
Imaging photoplethysmography (iPPG) is an emerging technology used to assess microcirculation and cardiovascular signs by collecting backscattered light from illuminated tissue using optical imaging sensors. The aim of this study was to study how effective smart garment fabrics could be capturing physiological signs in a non-contact mode. The present work demonstrates a feasible approach of, instead of using conventional high-power illumination sources, integrating a grid of surface-mounted light emitting diodes (LEDs) into cotton fabric to spotlight the region of interest (ROI). The green and the red LEDs (525 and 660 nm) placed on a small cotton substrate were used to locally illuminate palm skin in a dual-wavelength iPPG setup, where the backscattered light is transmitted to a remote image sensor through the garment fabric. The results show that the illuminations from both wavelength LEDs can be used to extract heart rate (HR) reaching an accuracy of 90% compared to a contact PPG probe. Stretching the fabric over the skin surface alters the morphology of iPPG signals, demonstrating a significantly higher pulsatile amplitude in both channels of green and red illuminations. The skin compression by the fabric could be potentially utilised to enhance the penetration of illumination into cutaneous microvascular beds. The outcome could lead a new avenue of non-contact opto-physiological monitoring and assessment with functional garment fabrics.
Nam, Yunyoung; Nam, Yun-Cheol
2017-10-19
Smartphones and tablets are widely used in medical fields, which can improve healthcare and reduce healthcare costs. Many medical applications for smartphones and tablets have already been developed and widely used by both health professionals and patients. Specifically, video recordings of fingertips made using a smartphone camera contain a pulsatile component caused by the cardiac pulse equivalent to that present in a photoplethysmographic signal. By performing peak detection on the pulsatile signal, it is possible to estimate a continuous heart rate and a respiratory rate. To estimate the heart rate and respiratory rate accurately, which pixel regions of the color bands give the most optimal signal quality should be investigated. In this paper, we investigate signal quality to determine the best signal quality by the largest amplitude values for three different smartphones under different conditions. We conducted several experiments to obtain reliable PPG signals and compared the PPG signal strength in the three color bands when the flashlight was both on and off. We also evaluated the intensity changes of PPG signals obtained from the smartphones with motion artifacts and fingertip pressure force. Furthermore, we have compared the PSNR of PPG signals of the full-size images with that of the region of interests (ROIs).
Portable two-channel PPG cardiovascular sensor device
NASA Astrophysics Data System (ADS)
Spigulis, Janis; Erts, Renars; Ozols, Maris
2003-10-01
A portable sensor device for simultaneous detection and processing of skin-remitted optical signals from any two sites of the body has been developed and tested. The photoplethysmography (PPG) principle was applied to follow the dilatation and contraction of skin blood vessels during the cardiac cycle. The newly developed two-channel approach allows to estimate the vascular blood flow resistance by analysis of time shifts between the PPG pulses detected at different body sites. Potential of the sensor device for express-assessment of human cardio-vascular condition and for body fitness tests has been demonstrated.
Weinschenk, Stefan W; Beise, Reinhard D; Lorenz, Jürgen
2016-08-01
We analyzed heart rate variability (HRV) taken by ECG and photoplethysmography (PPG) to assess their agreement. We also analyzed the sensitivity and specificity of PPG to identify subjects with low HRV as an example of its potential use for clinical applications. The HRV parameters: mean heart rate (HR), amplitude, and ratio of heart rate oscillation (E-I difference, E/I ratio), RMSSD, SDNN, and Power LF, were measured during 1-min deep breathing tests (DBT) in 343 individuals, followed by a 5-min short-term HRV (s-HRV), where the HRV parameters: HR, SD1, SD2, SDNN, Stress Index, Power HF, Power LF, Power VLF, and Total Power, were determined as well. Parameters were compared through correlation analysis and agreement analysis by Bland-Altman plots. PPG derived parameters HR and SD2 in s-HRV showed better agreement than SD1, Power HF, and stress index, whereas in DBT HR, E/I ratio and SDNN were superior to Power LF and RMSSD. DBT yielded stronger agreement than s-HRV. A slight overestimation of PPG HRV over HCG HRV was found. HR, Total Power, and SD2 in the s-HRV, HR, Power LF, and SDNN in the DBT showed high sensitivity and specificity to detect individuals with poor HRV. Cutoff percentiles are given for the future development of PPG-based devices. HRV measured by PPG shows good agreement with ECG HRV when appropriate parameters are used, and PPG-based devices can be employed as an easy screening tool to detect individuals with poor HRV, especially in the 1-min DBT test.
NASA Astrophysics Data System (ADS)
Imms, Ryan; Hu, Sijung; Azorin-Peris, Vicente; Trico, Michaël.; Summers, Ron
2014-03-01
Non-contact imaging photoplethysmography (PPG) is a recent development in the field of physiological data acquisition, currently undergoing a large amount of research to characterize and define the range of its capabilities. Contact-based PPG techniques have been broadly used in clinical scenarios for a number of years to obtain direct information about the degree of oxygen saturation for patients. With the advent of imaging techniques, there is strong potential to enable access to additional information such as multi-dimensional blood perfusion and saturation mapping. The further development of effective opto-physiological monitoring techniques is dependent upon novel modelling techniques coupled with improved sensor design and effective signal processing methodologies. The biometric signal and imaging processing platform (bSIPP) provides a comprehensive set of features for extraction and analysis of recorded iPPG data, enabling direct comparison with other biomedical diagnostic tools such as ECG and EEG. Additionally, utilizing information about the nature of tissue structure has enabled the generation of an engineering model describing the behaviour of light during its travel through the biological tissue. This enables the estimation of the relative oxygen saturation and blood perfusion in different layers of the tissue to be calculated, which has the potential to be a useful diagnostic tool.
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, Mohamed
2012-01-01
Photoplethysmography (PPG) is used to estimate the skin blood flow using infrared light. Researchers from different domains of science have become increasingly interested in PPG because of its advantages as non-invasive, inexpensive, and convenient diagnostic tool. Traditionally, it measures the oxygen saturation, blood pressure, cardiac output, and for assessing autonomic functions. Moreover, PPG is a promising technique for early screening of various atherosclerotic pathologies and could be helpful for regular GP-assessment but a full understanding of the diagnostic value of the different features is still lacking. Recent studies emphasise the potential information embedded in the PPG waveform signal and it deserves further attention for its possible applications beyond pulse oximetry and heart-rate calculation. Therefore, this overview discusses different types of artifact added to PPG signal, characteristic features of PPG waveform, and existing indexes to evaluate for diagnoses. PMID:22845812
Cicone, Antonio; Wu, Hau-Tieng
2017-01-01
Despite the population of the noninvasive, economic, comfortable, and easy-to-install photoplethysmography (PPG), it is still lacking a mathematically rigorous and stable algorithm which is able to simultaneously extract from a single-channel PPG signal the instantaneous heart rate (IHR) and the instantaneous respiratory rate (IRR). In this paper, a novel algorithm called deppG is provided to tackle this challenge. deppG is composed of two theoretically solid nonlinear-type time-frequency analyses techniques, the de-shape short time Fourier transform and the synchrosqueezing transform, which allows us to extract the instantaneous physiological information from the PPG signal in a reliable way. To test its performance, in addition to validating the algorithm by a simulated signal and discussing the meaning of “instantaneous,” the algorithm is applied to two publicly available batch databases, the Capnobase and the ICASSP 2015 signal processing cup. The former contains PPG signals relative to spontaneous or controlled breathing in static patients, and the latter is made up of PPG signals collected from subjects doing intense physical activities. The accuracies of the estimated IHR and IRR are compared with the ones obtained by other methods, and represent the state-of-the-art in this field of research. The results suggest the potential of deppG to extract instantaneous physiological information from a signal acquired from widely available wearable devices, even when a subject carries out intense physical activities. PMID:29018352
Optical multichannel sensing of skin blood pulsations
NASA Astrophysics Data System (ADS)
Spigulis, Janis; Erts, Renars; Kukulis, Indulis; Ozols, Maris; Prieditis, Karlis
2004-09-01
Time resolved detection and analysis of the skin back-scattered optical signals (reflection photoplethysmography or PPG) provide information on skin blood volume pulsations and can serve for cardiovascular assessment. The multi-channel PPG concept has been developed and clinically verified in this study. Portable two- and four-channel PPG monitoring devices have been designed for real-time data acquisition and processing. The multi-channel devices were successfully applied for cardiovascular fitness tests and for early detection of arterial occlusions in extremities. The optically measured heartbeat pulse wave propagation made possible to estimate relative arterial resistances for numerous patients and healthy volunteers.
A Pulse Rate Detection Method for Mouse Application Based on Multi-PPG Sensors
Chen, Wei-Hao
2017-01-01
Heart rate is an important physiological parameter for healthcare. Among measurement methods, photoplethysmography (PPG) is an easy and convenient method for pulse rate detection. However, as the PPG signal faces the challenge of motion artifacts and is constrained by the position chosen, the purpose of this paper is to implement a comfortable and easy-to-use multi-PPG sensor module combined with a stable and accurate real-time pulse rate detection method on a computer mouse. A weighted average method for multi-PPG sensors is used to adjust the weight of each signal channel in order to raise the accuracy and stability of the detected signal, therefore reducing the disturbance of noise under the environment of moving effectively and efficiently. According to the experiment results, the proposed method can increase the usability and probability of PPG signal detection on palms. PMID:28708112
Spatio-temporal analysis of blood perfusion by imaging photoplethysmography
NASA Astrophysics Data System (ADS)
Zaunseder, Sebastian; Trumpp, Alexander; Ernst, Hannes; Förster, Michael; Malberg, Hagen
2018-02-01
Imaging photoplethysmography (iPPG) has attracted much attention over the last years. The vast majority of works focuses on methods to reliably extract the heart rate from videos. Only a few works addressed iPPGs ability to exploit spatio-temporal perfusion pattern to derive further diagnostic statements. This work directs at the spatio-temporal analysis of blood perfusion from videos. We present a novel algorithm that bases on the two-dimensional representation of the blood pulsation (perfusion map). The basic idea behind the proposed algorithm consists of a pairwise estimation of time delays between photoplethysmographic signals of spatially separated regions. The probabilistic approach yields a parameter denoted as perfusion speed. We compare the perfusion speed versus two parameters, which assess the strength of blood pulsation (perfusion strength and signal to noise ratio). Preliminary results using video data with different physiological stimuli (cold pressure test, cold face test) show that all measures are influenced by those stimuli (some of them with statistical certainty). The perfusion speed turned out to be more sensitive than the other measures in some cases. However, our results also show that the intraindividual stability and interindividual comparability of all used measures remain critical points. This work proves the general feasibility of employing the perfusion speed as novel iPPG quantity. Future studies will address open points like the handling of ballistocardiographic effects and will try to deepen the understanding of the predominant physiological mechanisms and their relation to the algorithmic performance.
Reflectance Photoplethysmography as Noninvasive Monitoring of Tissue Blood Perfusion.
Abay, Tomas Ysehak; Kyriacou, Panayiotis A
2015-09-01
In the last decades, photoplethysmography (PPG) has been used as a noninvasive technique for monitoring arterial oxygen saturation by pulse oximetry (PO), whereas near-infrared spectroscopy (NIRS) has been employed for monitoring tissue blood perfusion. While NIRS offers more parameters to evaluate oxygen delivery and consumption in deep tissues, PO only assesses the state of oxygen delivery. For a broader assessment of blood perfusion, this paper explores the utilization of dual-wavelength PPG by using the pulsatile (ac) and continuous (dc) PPG for the estimation of arterial oxygen saturation (SpO2) by conventional PO. Additionally, the Beer-Lambert law is applied to the dc components only for the estimation of changes in deoxyhemoglobin (HHb), oxyhemoglobin (HbO2), and total hemoglobin (tHb) as in NIRS. The system was evaluated on the forearm of 21 healthy volunteers during induction of venous occlusion (VO) and total occlusion (TO). A reflectance PPG probe and NIRS sensor were applied above the brachioradialis, PO sensors were applied on the fingers, and all the signals were acquired simultaneously. While NIRS and forearm SpO2 indicated VO, SpO2 from the finger did not exhibit any significant drop from baseline. During TO, all the indexes indicated the change in blood perfusion. HHb, HbO2, and tHb changes estimated by PPG presented high correlation with the same parameters obtained by NIRS during VO (r(2) = 0.960, r(2) = 0.821, and r(2) = 0.974, respectively) and during TO (r(2) = 0.988, r(2) = 0.940, and r(2) = 0.938, respectively). The system demonstrated the ability to extract valuable information from PPG signals for a broader assessment of tissue blood perfusion.
Shi, Lei; Sun, Peng; Pang, Yu; Luo, Zhiyong; Wang, Wei; Wang, Yanxiang
2016-02-01
Heart rate variability (HRV) is the difference between the successive changes in the heartbeat cycle, and it is produced in the autonomic nervous system modulation of the sinus node of the heart. The HRV is a valuable indicator in predicting the sudden cardiac death and arrhythmic events. Traditional analysis of HRV is based on a multielectrocardiogram (ECG), but the ECG signal acquisition is complex, so we have designed an HRV analysis system based on photoplethysmography (PPG). PPG signal is collected by a microcontroller from human's finger, and it is sent to the terminal via USB-Serial module. The terminal software not only collects the data and plot waveforms, but also stores the data for future HRV analysis. The system is small in size, low in power consumption, and easy for operation. It is suitable for daily care no matter whether it is used at home or in a hospital.
Optical multichannel monitoring of skin blood pulsations for cardiovascular assessment
NASA Astrophysics Data System (ADS)
Spigulis, Janis; Erts, Renars; Ozols, Maris
2004-07-01
Time resolved detection and analysis of the skin back-scattered optical signals (reflection photoplethysmography or PPG) provide rich information on skin blood volume pulsations and can serve for cardiovascular assessment. The multichannel PPG concept has been developed and clinically verified in this work. Simultaneous data flow from several body locations allows to study the heartbeat pulse wave propagation in real time and to evaluate the vascular resistance. Portable two- and four-channel PPG monitoring devices and special software have been designed for real-time data acquisition and processing. The multi-channel devices were successfully applied for cardiovascular fitness tests and for early detection of arterial occlusions.
A Hybrid Wavelet-Based Method for the Peak Detection of Photoplethysmography Signals.
Li, Suyi; Jiang, Shanqing; Jiang, Shan; Wu, Jiang; Xiong, Wenji; Diao, Shu
2017-01-01
The noninvasive peripheral oxygen saturation (SpO 2 ) and the pulse rate can be extracted from photoplethysmography (PPG) signals. However, the accuracy of the extraction is directly affected by the quality of the signal obtained and the peak of the signal identified; therefore, a hybrid wavelet-based method is proposed in this study. Firstly, we suppressed the partial motion artifacts and corrected the baseline drift by using a wavelet method based on the principle of wavelet multiresolution. And then, we designed a quadratic spline wavelet modulus maximum algorithm to identify the PPG peaks automatically. To evaluate this hybrid method, a reflective pulse oximeter was used to acquire ten subjects' PPG signals under sitting, raising hand, and gently walking postures, and the peak recognition results on the raw signal and on the corrected signal were compared, respectively. The results showed that the hybrid method not only corrected the morphologies of the signal well but also optimized the peaks identification quality, subsequently elevating the measurement accuracy of SpO 2 and the pulse rate. As a result, our hybrid wavelet-based method profoundly optimized the evaluation of respiratory function and heart rate variability analysis.
Facial Video-Based Photoplethysmography to Detect HRV at Rest.
Moreno, J; Ramos-Castro, J; Movellan, J; Parrado, E; Rodas, G; Capdevila, L
2015-06-01
Our aim is to demonstrate the usefulness of photoplethysmography (PPG) for analyzing heart rate variability (HRV) using a standard 5-min test at rest with paced breathing, comparing the results with real RR intervals and testing supine and sitting positions. Simultaneous recordings of R-R intervals were conducted with a Polar system and a non-contact PPG, based on facial video recording on 20 individuals. Data analysis and editing were performed with individually designated software for each instrument. Agreement on HRV parameters was assessed with concordance correlations, effect size from ANOVA and Bland and Altman plots. For supine position, differences between video and Polar systems showed a small effect size in most HRV parameters. For sitting position, these differences showed a moderate effect size in most HRV parameters. A new procedure, based on the pixels that contained more heart beat information, is proposed for improving the signal-to-noise ratio in the PPG video signal. Results were acceptable in both positions but better in the supine position. Our approach could be relevant for applications that require monitoring of stress or cardio-respiratory health, such as effort/recuperation states in sports. © Georg Thieme Verlag KG Stuttgart · New York.
A Hybrid Wavelet-Based Method for the Peak Detection of Photoplethysmography Signals
Jiang, Shanqing; Jiang, Shan; Wu, Jiang; Xiong, Wenji
2017-01-01
The noninvasive peripheral oxygen saturation (SpO2) and the pulse rate can be extracted from photoplethysmography (PPG) signals. However, the accuracy of the extraction is directly affected by the quality of the signal obtained and the peak of the signal identified; therefore, a hybrid wavelet-based method is proposed in this study. Firstly, we suppressed the partial motion artifacts and corrected the baseline drift by using a wavelet method based on the principle of wavelet multiresolution. And then, we designed a quadratic spline wavelet modulus maximum algorithm to identify the PPG peaks automatically. To evaluate this hybrid method, a reflective pulse oximeter was used to acquire ten subjects' PPG signals under sitting, raising hand, and gently walking postures, and the peak recognition results on the raw signal and on the corrected signal were compared, respectively. The results showed that the hybrid method not only corrected the morphologies of the signal well but also optimized the peaks identification quality, subsequently elevating the measurement accuracy of SpO2 and the pulse rate. As a result, our hybrid wavelet-based method profoundly optimized the evaluation of respiratory function and heart rate variability analysis. PMID:29250135
Toward Hypertension Prediction Based on PPG-Derived HRV Signals: a Feasibility Study.
Lan, Kun-Chan; Raknim, Paweeya; Kao, Wei-Fong; Huang, Jyh-How
2018-04-21
Heart rate variability (HRV) is often used to assess the risk of cardiovascular disease, and data on this can be obtained via electrocardiography (ECG). However, collecting heart rate data via photoplethysmography (PPG) is now a lot easier. We investigate the feasibility of using the PPG-based heart rate to estimate HRV and predict diseases. We obtain three months of PPG-based heart rate data from subjects with and without hypertension, and calculate the HRV based on various forms of time and frequency domain analysis. We then apply a data mining technique to this estimated HRV data, to see if it is possible to correctly identify patients with hypertension. We use six HRV parameters to predict hypertension, and find SDNN has the best predictive power. We show that early disease prediction is possible through collecting one's PPG-based heart rate information.
Evaluation of arterial oxygen saturation using RGB camera-based remote photoplethysmography
NASA Astrophysics Data System (ADS)
Nishidate, Izumi; Nakano, Kazuya; McDuff, Daniel; Niizeki, Kyuichi; Aizu, Yoshihisa; Haneishi, Hideaki
2018-02-01
Plethysmogram is the periodic variation in blood volume due to the cardiac pulse traveling through the body. Photo-plethysmograph (PPG) has been widely used to assess the cardiovascular system such as heart rate, blood pressure, cardiac output, vascular compliance. We have previously proposed a non-contact PPG imaging method using a digital red-green-blue camera. In the method, the Monte Carlo simulation for light transport is used to specify a relationship among the RGB-values and the concentrations of oxygenated hemoglobin (CHbO) and deoxygenated hemoglobin (CHbR). The total hemoglobin concentration (CHbT) can be calculated as a sum of CHbO and CHbR. Applying the fast Fourier transform (FFT) band pass filters to each pixel of the sequential images for CHbT along the time line, two-dimentional plethysmogram can be reconstructed. In this study, we further extend the method to imaging the arterial oxygen saturation (SaO2). The PPG signals for both CHbO and CHbR are extracted by the FFT band pass filter and the pulse wave amplitudes (PWAs) of CHbO and CHbR are calculated. We assume that the PWA for CHbO and that for CHbR are decreased and increased as SaO2 is decreased. The ratio of PWA for CHbO and that for CHbR are associated to the reference value of SaO2 measured by a commercially available pulse oximeter, which provide an empirical formula to estimate SaO2 from the PPG signal at each pixel of RGB image. In vivo animal experiments with rats during varying the fraction of inspired oxygen (FiO2) demonstrated the feasibility of the proposed method.
Abay, T Y; Kyriacou, P A
2018-06-01
Photoplethysmography (PPG) is an optical technique that measures blood volume variations. The main application of dual-wavelength PPG is pulse oximetry, in which the arterial oxygen saturation (SpO[Formula: see text]) is calculated noninvasively. However, the PPG waveform contains other significant physiological information that can be used in conjunction to SpO[Formula: see text] for the assessment of oxygenation and blood volumes changes. This paper investigates the use of near infrared spectroscopy (NIRS) processing techniques for extracting relative concentration changes of oxygenated ([Formula: see text]HbO[Formula: see text]), reduced ([Formula: see text]HHb) and total haemoglobin ([Formula: see text]tHb) from dual-wavelength PPG signals during intermittent pressure-increasing vascular occlusions. A reflectance PPG sensor was attached on the left forearm of nineteen (n = 19) volunteers, along with a reference NIRS sensor positioned on the same forearm, above the left brachioradialis. The investigation protocol consisted of seven intermittent and pressure-increasing vascular occlusions. Relative changes in haemoglobin concentrations were obtained by applying the modified Beer-Lambert law to PPG signals, while oxygenation changes were estimated by the difference between red and infrared attenuations of DC PPGs (A[Formula: see text] = [Formula: see text]A[Formula: see text] - [Formula: see text]A[Formula: see text]) and by the conventional SpO[Formula: see text]. The [Formula: see text]HbO[Formula: see text], [Formula: see text]HHb, [Formula: see text]tHb from the PPG signals indicated significant changes in perfusion induced by either partial and complete occlusions (p < 0.05). The trends in the variables extracted from PPG showed good correlation with the same parameters measured by the reference NIRS monitor. Bland and Altman analysis of agreement between PPG and NIRS showed underestimation of the magnitude of changes by the PPG. A[Formula: see text] indicated significant changes for occlusion pressures exceeding 20 mmHg (p < 0.05) and correlation with tissue oxygenation changes measured by NIRS, while SpO[Formula: see text] had significant changes after 40 mmHg (p < 0.05). Relative changes in haemoglobin concentrations can be estimated from PPG signals and they showed a good level of accuracy in the detection of perfusion and oxygenation changes induced by different degrees of intermittent vascular occlusions. These results can open up to new applications of the PPG waveform in the detection of blood volumes and oxygenation changes.
Optical non-invasive monitoring of skin blood pulsations
NASA Astrophysics Data System (ADS)
Spīgulis, Jānis
2005-08-01
Time resolved detection and analysis of the skin backscattered optical signals (remission photoplethysmography or PPG) provide rich information on skin blood volume pulsations and can serve for reliable cardiovascular assessment. The single- and multi-channel PPG concepts are discussed in this work. Simultaneous data flow from several body locations allows one to study the heartbeat pulse wave propagation in real time and evaluate the vascular resistance. Portable single-, dual- and four-channel PPG monitoring devices with special software have been designed for real-time data acquisition and processing. The clinical studies confirmed their potential in the monitoring of heart arrhythmias, drug tests, steady-state cardiovascular assessment, body fitness control, and express diagnostics of the arterial occlusions.
Optical noninvasive monitoring of skin blood pulsations
NASA Astrophysics Data System (ADS)
Spigulis, Janis
2005-04-01
Time-resolved detection and analysis of skin backscattered optical signals (remission photoplethysmography or PPG) provide rich information on skin blood volume pulsations and can serve for reliable cardiovascular assessment. Single- and multiple-channel PPG concepts are discussed. Simultaneous data flow from several locations on the human body allows us to study heartbeat pulse-wave propagation in real time and to evaluate vascular resistance. Portable single-, dual-, and four-channel PPG monitoring devices with special software have been designed for real-time data acquisition and processing. The prototype devices have been clinically studied, and their potential for monitoring heart arrhythmias, drug-efficiency tests, steady-state cardiovascular assessment, body fitness control, and express diagnostics of the arterial occlusions has been confirmed.
CameraHRV: robust measurement of heart rate variability using a camera
NASA Astrophysics Data System (ADS)
Pai, Amruta; Veeraraghavan, Ashok; Sabharwal, Ashutosh
2018-02-01
The inter-beat-interval (time period of the cardiac cycle) changes slightly for every heartbeat; this variation is measured as Heart Rate Variability (HRV). HRV is presumed to occur due to interactions between the parasym- pathetic and sympathetic nervous system. Therefore, it is sometimes used as an indicator of the stress level of an individual. HRV also reveals some clinical information about cardiac health. Currently, HRV is accurately measured using contact devices such as a pulse oximeter. However, recent research in the field of non-contact imaging Photoplethysmography (iPPG) has made vital sign measurements using just the video recording of any exposed skin (such as a person's face) possible. The current signal processing methods for extracting HRV using peak detection perform well for contact-based systems but have poor performance for the iPPG signals. The main reason for this poor performance is the fact that current methods are sensitive to large noise sources which are often present in iPPG data. Further, current methods are not robust to motion artifacts that are common in iPPG systems. We developed a new algorithm, CameraHRV, for robustly extracting HRV even in low SNR such as is common with iPPG recordings. CameraHRV combined spatial combination and frequency demodulation to obtain HRV from the instantaneous frequency of the iPPG signal. CameraHRV outperforms other current methods of HRV estimation. Ground truth data was obtained from FDA-approved pulse oximeter for validation purposes. CameraHRV on iPPG data showed an error of 6 milliseconds for low motion and varying skin tone scenarios. The improvement in error was 14%. In case of high motion scenarios like reading, watching and talking, the error was 10 milliseconds.
Matsumura, Kenta; Rolfe, Peter; Lee, Jihyoung; Yamakoshi, Takehiro
2014-01-01
Recent progress in information and communication technologies has made it possible to measure heart rate (HR) and normalized pulse volume (NPV), which are important physiological indices, using only a smartphone. This has been achieved with reflection mode photoplethysmography (PPG), by using a smartphone’s embedded flash as a light source and the camera as a light sensor. Despite its widespread use, the method of PPG is susceptible to motion artifacts as physical displacements influence photon propagation phenomena and, thereby, the effective optical path length. Further, it is known that the wavelength of light used for PPG influences the photon penetration depth and we therefore hypothesized that influences of motion artifact could be wavelength-dependant. To test this hypothesis, we made measurements in 12 healthy volunteers of HR and NPV derived from reflection mode plethysmograms recorded simultaneously at three different spectral regions (red, green and blue) at the same physical location with a smartphone. We then assessed the accuracy of the HR and NPV measurements under the influence of motion artifacts. The analyses revealed that the accuracy of HR was acceptably high with all three wavelengths (all rs > 0.996, fixed biases: −0.12 to 0.10 beats per minute, proportional biases: r = −0.29 to 0.03), but that of NPV was the best with green light (r = 0.791, fixed biases: −0.01 arbitrary units, proportional bias: r = 0.11). Moreover, the signal-to-noise ratio obtained with green and blue light PPG was higher than that of red light PPG. These findings suggest that green is the most suitable color for measuring HR and NPV from the reflection mode photoplethysmogram under motion artifact conditions. We conclude that the use of green light PPG could be of particular benefit in ambulatory monitoring where motion artifacts are a significant issue. PMID:24618594
An adaptive deep learning approach for PPG-based identification.
Jindal, V; Birjandtalab, J; Pouyan, M Baran; Nourani, M
2016-08-01
Wearable biosensors have become increasingly popular in healthcare due to their capabilities for low cost and long term biosignal monitoring. This paper presents a novel two-stage technique to offer biometric identification using these biosensors through Deep Belief Networks and Restricted Boltzman Machines. Our identification approach improves robustness in current monitoring procedures within clinical, e-health and fitness environments using Photoplethysmography (PPG) signals through deep learning classification models. The approach is tested on TROIKA dataset using 10-fold cross validation and achieved an accuracy of 96.1%.
Fan, Feiyi; Yan, Yuepeng; Tang, Yongzhong; Zhang, Hao
2017-12-01
Monitoring pulse oxygen saturation (SpO 2 ) and heart rate (HR) using photoplethysmography (PPG) signal contaminated by a motion artifact (MA) remains a difficult problem, especially when the oximeter is not equipped with a 3-axis accelerometer for adaptive noise cancellation. In this paper, we report a pioneering investigation on the impact of altering the frame length of Molgedey and Schuster independent component analysis (ICAMS) on performance, design a multi-classifier fusion strategy for selecting the PPG correlated signal component, and propose a novel approach to extract SpO 2 and HR readings from PPG signal contaminated by strong MA interference. The algorithm comprises multiple stages, including dual frame length ICAMS, a multi-classifier-based PPG correlated component selector, line spectral analysis, tree-based HR monitoring, and post-processing. Our approach is evaluated by multi-subject tests. The root mean square error (RMSE) is calculated for each trial. Three statistical metrics are selected as performance evaluation criteria: mean RMSE, median RMSE and the standard deviation (SD) of RMSE. The experimental results demonstrate that a shorter ICAMS analysis window probably results in better performance in SpO 2 estimation. Notably, the designed multi-classifier signal component selector achieved satisfactory performance. The subject tests indicate that our algorithm outperforms other baseline methods regarding accuracy under most criteria. The proposed work can contribute to improving the performance of current pulse oximetry and personal wearable monitoring devices. Copyright © 2017 Elsevier Ltd. All rights reserved.
Shafique, M; Kyriacou, P A; Pal, S K
2012-06-01
Photoplethysmography (PPG) is a technique widely used to monitor volumetric blood changes induced by cardiac pulsations. Pulse oximetry uses the technique of PPG to estimate arterial oxygen saturation values (SpO₂). In poorly perfused tissues, SpO₂ readings may be compromised due to the poor quality of the PPG signals. A multimode finger PPG probe that operates simultaneously in reflectance, transmittance and a combined mode called "transreflectance" was developed, in an effort to improve the quality of the PPG signals in states of hypoperfusion. Experiments on 20 volunteers were conducted to evaluate the performance of the multimode PPG sensor and compare the results with a commercial transmittance pulse oximeter. A brachial blood pressure cuff was used to induce artificial hypoperfusion. Results showed that the amplitude of the transreflectance AC PPG signals were significantly different (p < 0.05) than the AC PPG signals obtained from the other two conventional PPG sensors (reflectance and transmittance). At induced brachial pressures between 90 and 135 mmHg, the reflectance finger pulse oximeter failed 25 times (failure rate 42.2 %) to estimate SpO₂ values, whereas the transmittance pulse oximeter failed 8 times (failure rate 15.5 %). The transreflectance pulse oximeter failed only 3 times (failure rate 6.8 %) and the commercial pulse oximeter failed 17 times (failure rate 29.4 %).
van Velzen, Marit H N; Loeve, Arjo J; Niehof, Sjoerd P; Mik, Egbert G
2017-11-01
Photoplethysmography (PPG) is a widely available non-invasive optical technique to visualize pressure pulse waves (PWs). Pulse transit time (PTT) is a physiological parameter that is often derived from calculations on ECG and PPG signals and is based on tightly defined characteristics of the PW shape. PPG signals are sensitive to artefacts. Coughing or movement of the subject can affect PW shapes that much that the PWs become unsuitable for further analysis. The aim of this study was to develop an algorithm that automatically and objectively eliminates unsuitable PWs. In order to develop a proper algorithm for eliminating unsuitable PWs, a literature study was conducted. Next, a '7Step PW-Filter' algorithm was developed that applies seven criteria to determine whether a PW matches the characteristics required to allow PTT calculation. To validate whether the '7Step PW-Filter' eliminates only and all unsuitable PWs, its elimination results were compared to the outcome of manual elimination of unsuitable PWs. The '7Step PW-Filter' had a sensitivity of 96.3% and a specificity of 99.3%. The overall accuracy of the '7Step PW-Filter' for detection of unsuitable PWs was 99.3%. Compared to manual elimination, using the '7Step PW-Filter' reduces PW elimination times from hours to minutes and helps to increase the validity, reliability and reproducibility of PTT data.
Development and optimization of a miniaturized fiber-optic photoplethysmographic sensor
NASA Astrophysics Data System (ADS)
Morley, Aisha; Davenport, John J.; Hickey, Michelle; Phillips, Justin P.
2017-11-01
Photoplethysmography (PPG) is a widely used technique for measuring blood oxygen saturation, commonly using an external pulse oximeter applied to a finger, toe, or earlobe. Previous research has demonstrated the utility of direct monitoring of the oxygen saturation of internal organs, using optical fibers to transmit light between the photodiode/light emitting diode and internal site. However, little research into the optimization and standardization of such a probe has yet been carried out. This research establishes the relationship between fiber separation distance and PPG signal, and between fiber core width and PPG signal. An ideal setup is suggested: 1000-μm fibers at a separation distance of 3 to 3.5 mm, which was found to produce signals around 0.35 V in amplitude with a low variation coefficient.
Mohamed Yacin, S; Srinivasa Chakravarthy, V; Manivannan, M
2011-11-01
Extraction of extra-cardiac information from photoplethysmography (PPG) signal is a challenging research problem with significant clinical applications. In this study, radial basis function neural network (RBFNN) is used to reconstruct the gastric myoelectric activity (GMA) slow wave from finger PPG signal. Finger PPG and GMA (measured using Electrogastrogram, EGG) signals were acquired simultaneously at the sampling rate of 100 Hz from ten healthy subjects. Discrete wavelet transform (DWT) was used to extract slow wave (0-0.1953 Hz) component from the finger PPG signal; this slow wave PPG was used to reconstruct EGG. A RBFNN is trained on signals obtained from six subjects in both fasting and postprandial conditions. The trained network is tested on data obtained from the remaining four subjects. In the earlier study, we have shown the presence of GMA information in finger PPG signal using DWT and cross-correlation method. In this study, we explicitly reconstruct gastric slow wave from finger PPG signal by the proposed RBFNN-based method. It was found that the network-reconstructed slow wave provided significantly higher (P < 0.0001) correlation (≥ 0.9) with the subject's EGG slow wave than the correlation obtained (≈0.7) between the PPG slow wave from DWT and the EEG slow wave. Our results showed that a simple finger PPG signal can be used to reconstruct gastric slow wave using RBFNN method.
Comparison of heart rate variability and pulse rate variability detected with photoplethysmography
NASA Astrophysics Data System (ADS)
Rauh, Robert; Limley, Robert; Bauer, Rainer-Dieter; Radespiel-Troger, Martin; Mueck-Weymann, Michael
2004-08-01
This study compares ear photoplethysmography (PPG) and electrocardiogram (ECG) in providing accurate heart beat intervals for use in calculations of heart rate variability (HRV, from ECG) or of pulse rate variability (PRV, from PPG) respectively. Simultaneous measurements were taken from 44 healthy subjects at rest during spontaneous breathing and during forced metronomic breathing (6/min). Under both conditions, highly significant (p > 0.001) correlations (1.0 > r > 0.97) were found between all evaluated common HRV and PRV parameters. However, under both conditions the PRV parameters were higher than HRV. In addition, we calculated the limits of agreement according to Bland and Altman between both techniques and found good agreement (< 10% difference) for heart rate and standard deviation of normal-to-normal intervals (SDNN), but only moderate (10-20%) or even insufficient (> 20%) agreement for other standard HRV and PRV parameters. Thus, PRV data seem to be acceptable for screening purposes but, at least at this state of knowledge, not for medical decision making. However, further studies are needed before more certain determination can be made.
Quantitative evaluation of photoplethysmographic artifact reduction for pulse oximetry
NASA Astrophysics Data System (ADS)
Hayes, Matthew J.; Smith, Peter R.
1999-01-01
Motion artefact corruption of pulse oximeter output, causing both measurement inaccuracies and false alarm conditions, is a primary restriction in the current clinical practice and future applications of this useful technique. Artefact reduction in photoplethysmography (PPG), and therefore by application in pulse oximetry, is demonstrated using a novel non-linear methodology recently proposed by the authors. The significance of these processed PPG signals for pulse oximetry measurement is discussed, with particular attention to the normalization inherent in the artefact reduction process. Quantitative experimental investigation of the performance of PPG artefact reduction is then utilized to evaluate this technology for application to pulse oximetry. While the successfully demonstrated reduction of severe artefacts may widen the applicability of all PPG technologies and decrease the occurrence of pulse oximeter false alarms, the observed reduction of slight artefacts suggests that many such effects may go unnoticed in clinical practice. The signal processing and output averaging used in most commercial oximeters can incorporate these artefact errors into the output, while masking the true PPG signal corruption. It is therefore suggested that PPG artefact reduction should be incorporated into conventional pulse oximetry measurement, even in the absence of end-user artefact problems.
Development of a remote photoplethysmographic technique for human biometrics
NASA Astrophysics Data System (ADS)
Shi, Ping; Hu, Sijung; Echiadis, Angelos; Azorin Peris, Vicente; Zheng, Jia; Zhu, Yisheng
2009-02-01
Non-contact reflection photoplethysmography (NRPPG) is being developed to trace pulse features for comparison with contact photoplethysmography (CPPG). Simultaneous recordings of CPPG and NRPPG signals from 22 healthy subjects were studied. The power spectrum of PPG signals were analysed and compared between NRPPG and CPPG. The recurrence plot (RP) was used as a graphical tool to visualize the time dependent behaviour of the dynamics of the pulse signals. The agreement between NRPPG and CPPG for physiological monitoring, i.e. HRV parameters, was determined by means of the Bland-Altman plot and Pearson's correlation coefficient. The results indicated that NRPPG could be used for the assessment of cardio-physiological signals.
Rapid Prototyping of a Smart Device-based Wireless Reflectance Photoplethysmograph
Ghamari, M.; Aguilar, C.; Soltanpur, C.; Nazeran, H.
2017-01-01
This paper presents the design, fabrication, and testing of a wireless heart rate (HR) monitoring device based on photoplethysmography (PPG) and smart devices. PPG sensors use infrared (IR) light to obtain vital information to assess cardiac health and other physiologic conditions. The PPG data that are transferred to a computer undergo further processing to derive the Heart Rate Variability (HRV) signal, which is analyzed to generate quantitative markers of the Autonomic Nervous System (ANS). The HRV signal has numerous monitoring and diagnostic applications. To this end, wireless connectivity plays an important role in such biomedical instruments. The photoplethysmograph consists of an optical sensor to detect the changes in the light intensity reflected from the illuminated tissue, a signal conditioning unit to prepare the reflected light for further signal conditioning through amplification and filtering, a low-power microcontroller to control and digitize the analog PPG signal, and a Bluetooth module to transmit the digital data to a Bluetooth-based smart device such as a tablet. An Android app is then used to enable the smart device to acquire and digitally display the received analog PPG signal in real-time on the smart device. This article is concluded with the prototyping of the wireless PPG followed by the verification procedures of the PPG and HRV signals acquired in a laboratory environment. PMID:28959119
Rapid Prototyping of a Smart Device-based Wireless Reflectance Photoplethysmograph.
Ghamari, M; Aguilar, C; Soltanpur, C; Nazeran, H
2016-03-01
This paper presents the design, fabrication, and testing of a wireless heart rate (HR) monitoring device based on photoplethysmography (PPG) and smart devices. PPG sensors use infrared (IR) light to obtain vital information to assess cardiac health and other physiologic conditions. The PPG data that are transferred to a computer undergo further processing to derive the Heart Rate Variability (HRV) signal, which is analyzed to generate quantitative markers of the Autonomic Nervous System (ANS). The HRV signal has numerous monitoring and diagnostic applications. To this end, wireless connectivity plays an important role in such biomedical instruments. The photoplethysmograph consists of an optical sensor to detect the changes in the light intensity reflected from the illuminated tissue, a signal conditioning unit to prepare the reflected light for further signal conditioning through amplification and filtering, a low-power microcontroller to control and digitize the analog PPG signal, and a Bluetooth module to transmit the digital data to a Bluetooth-based smart device such as a tablet. An Android app is then used to enable the smart device to acquire and digitally display the received analog PPG signal in real-time on the smart device. This article is concluded with the prototyping of the wireless PPG followed by the verification procedures of the PPG and HRV signals acquired in a laboratory environment.
Comparison of HRV parameters derived from photoplethysmography and electrocardiography signals.
Jeyhani, Vala; Mahdiani, Shadi; Peltokangas, Mikko; Vehkaoja, Antti
2015-01-01
Heart rate variability (HRV) has become a useful tool in analysis of cardiovascular system in both research and clinical fields. HRV has been also used in other applications such as stress level estimation in wearable devices. HRV is normally obtained from ECG as the time interval of two successive R waves. Recently PPG has been proposed as an alternative for ECG in HRV analysis to overcome some difficulties in measurement of ECG. In addition, PPG-HRV is also used in some commercial devices such as modern optical wrist-worn heart rate monitors. However, some researches have shown that PPG is not a surrogate for heart rate variability analysis. In this work, HRV analysis was applied on beat-to-beat intervals obtained from ECG and PPG in 19 healthy male subjects. Some important HRV parameters were calculated from PPG-HRV and ECG-HRV. Maximum of PPG and its second derivative were considered as two methods for obtaining the beat-to-beat signals from PPG and the results were compared with those achieved from ECG-HRV. Our results show that the smallest error happens in SDNN and SD2 with relative error of 2.46% and 2%, respectively. The most affected parameter is pNN50 with relative error of 29.89%. In addition, in our trial, using the maximum of PPG gave better results than its second derivative.
Novel health monitoring method using an RGB camera.
Hassan, M A; Malik, A S; Fofi, D; Saad, N; Meriaudeau, F
2017-11-01
In this paper we present a novel health monitoring method by estimating the heart rate and respiratory rate using an RGB camera. The heart rate and the respiratory rate are estimated from the photoplethysmography (PPG) and the respiratory motion. The method mainly operates by using the green spectrum of the RGB camera to generate a multivariate PPG signal to perform multivariate de-noising on the video signal to extract the resultant PPG signal. A periodicity based voting scheme (PVS) was used to measure the heart rate and respiratory rate from the estimated PPG signal. We evaluated our proposed method with a state of the art heart rate measuring method for two scenarios using the MAHNOB-HCI database and a self collected naturalistic environment database. The methods were furthermore evaluated for various scenarios at naturalistic environments such as a motion variance session and a skin tone variance session. Our proposed method operated robustly during the experiments and outperformed the state of the art heart rate measuring methods by compensating the effects of the naturalistic environment.
Heart rate measurement based on face video sequence
NASA Astrophysics Data System (ADS)
Xu, Fang; Zhou, Qin-Wu; Wu, Peng; Chen, Xing; Yang, Xiaofeng; Yan, Hong-jian
2015-03-01
This paper proposes a new non-contact heart rate measurement method based on photoplethysmography (PPG) theory. With this method we can measure heart rate remotely with a camera and ambient light. We collected video sequences of subjects, and detected remote PPG signals through video sequences. Remote PPG signals were analyzed with two methods, Blind Source Separation Technology (BSST) and Cross Spectral Power Technology (CSPT). BSST is a commonly used method, and CSPT is used for the first time in the study of remote PPG signals in this paper. Both of the methods can acquire heart rate, but compared with BSST, CSPT has clearer physical meaning, and the computational complexity of CSPT is lower than that of BSST. Our work shows that heart rates detected by CSPT method have good consistency with the heart rates measured by a finger clip oximeter. With good accuracy and low computational complexity, the CSPT method has a good prospect for the application in the field of home medical devices and mobile health devices.
Automated Epileptic Seizure Detection Based on Wearable ECG and PPG in a Hospital Environment
De Cooman, Thomas; Gu, Ying; Cleeren, Evy; Claes, Kasper; Van Paesschen, Wim; Van Huffel, Sabine; Hunyadi, Borbála
2017-01-01
Electrocardiography has added value to automatically detect seizures in temporal lobe epilepsy (TLE) patients. The wired hospital system is not suited for a long-term seizure detection system at home. To address this need, the performance of two wearable devices, based on electrocardiography (ECG) and photoplethysmography (PPG), are compared with hospital ECG using an existing seizure detection algorithm. This algorithm classifies the seizures on the basis of heart rate features, extracted from the heart rate increase. The algorithm was applied to recordings of 11 patients in a hospital setting with 701 h capturing 47 (fronto-)temporal lobe seizures. The sensitivities of the hospital system, the wearable ECG device and the wearable PPG device were respectively 57%, 70% and 32%, with corresponding false alarms per hour of 1.92, 2.11 and 1.80. Whereas seizure detection performance using the wrist-worn PPG device was considerably lower, the performance using the wearable ECG is proven to be similar to that of the hospital ECG. PMID:29027928
Automated Epileptic Seizure Detection Based on Wearable ECG and PPG in a Hospital Environment.
Vandecasteele, Kaat; De Cooman, Thomas; Gu, Ying; Cleeren, Evy; Claes, Kasper; Paesschen, Wim Van; Huffel, Sabine Van; Hunyadi, Borbála
2017-10-13
Electrocardiography has added value to automatically detect seizures in temporal lobe epilepsy (TLE) patients. The wired hospital system is not suited for a long-term seizure detection system at home. To address this need, the performance of two wearable devices, based on electrocardiography (ECG) and photoplethysmography (PPG), are compared with hospital ECG using an existing seizure detection algorithm. This algorithm classifies the seizures on the basis of heart rate features, extracted from the heart rate increase. The algorithm was applied to recordings of 11 patients in a hospital setting with 701 h capturing 47 (fronto-)temporal lobe seizures. The sensitivities of the hospital system, the wearable ECG device and the wearable PPG device were respectively 57%, 70% and 32%, with corresponding false alarms per hour of 1.92, 2.11 and 1.80. Whereas seizure detection performance using the wrist-worn PPG device was considerably lower, the performance using the wearable ECG is proven to be similar to that of the hospital ECG.
Noncontact blood perfusion mapping in clinical applications
NASA Astrophysics Data System (ADS)
Iakovlev, Dmitry; Dwyer, Vincent; Hu, Sijung; Silberschmidt, Vadim
2016-04-01
Non-contact imaging photoplethysmography (iPPG) to detect pulsatile blood microcirculation in tissue has been selected as a successor to low spatial resolution and slow scanning blood perfusion techniques currently employed by clinicians. The proposed iPPG system employs a novel illumination source constructed of multiple high power LEDs with narrow spectral emission, which are temporally modulated and synchronised with a high performance sCMOS sensor. To ensure spectrum stability and prevent thermal wavelength drift due to junction temperature variations, each LED features a custom-designed thermal management system to effectively dissipate generated heat and auto-adjust current flow. The use of a multi-wavelength approach has resulted in simultaneous microvascular perfusion monitoring at various tissue depths, which is an added benefit for specific clinical applications. A synchronous detection algorithm to extract weak photoplethysmographic pulse-waveforms demonstrated robustness and high efficiency when applied to even small regions of 5 mm2. The experimental results showed evidences that the proposed system could achieve noticeable accuracy in blood perfusion monitoring by creating complex amplitude and phase maps for the tissue under examination.
Analysis of biomedical time signals for characterization of cutaneous diabetic micro-angiopathy
NASA Astrophysics Data System (ADS)
Kraitl, Jens; Ewald, Hartmut
2007-02-01
Photo-plethysmography (PPG) is frequently used in research on microcirculation of blood. It is a non-invasive procedure and takes minimal time to be carried out. Usually PPG time series are analyzed by conventional linear methods, mainly Fourier analysis. These methods may not be optimal for the investigation of nonlinear effects of the hearth circulation system like vasomotion, autoregulation, thermoregulation, breathing, heartbeat and vessels. The wavelet analysis of the PPG time series is a specific, sensitive nonlinear method for the in vivo identification of hearth circulation patterns and human health status. This nonlinear analysis of PPG signals provides additional information which cannot be detected using conventional approaches. The wavelet analysis has been used to study healthy subjects and to characterize the health status of patients with a functional cutaneous microangiopathy which was associated with diabetic neuropathy. The non-invasive in vivo method is based on the radiation of monochromatic light through an area of skin on the finger. A Photometrical Measurement Device (PMD) has been developed. The PMD is suitable for non-invasive continuous online monitoring of one or more biologic constituent values and blood circulation patterns.
Ye, Jing-Jhao; Chuang, Chiung-Cheng; Tai, Yu-Ting; Lee, Kuan-Ting; Hung, Kuo-Sheng
2017-09-01
Radiofrequency therapy (RFT) generates molecular motion and produces heat and electromagnetic effects on tissues, which attenuate pain sensation and thereby relieve pain. This study was to observe the altering trend of physiological parameters after RFT for chronic cervical or lumbar pain. This study recruited 66 patients with chronic cervical or lumbar pain and recorded their physiological parameters before and after RFT using heart rate variability (HRV) and photoplethysmography (PPG) to explore the feasibility of RFT efficacy assessment. The patients' visual analog scale scores significantly decreased after RFT and the HRV parameters that represented parasympathetic activity significantly changed (HR decreased, and R-R interval and low- and high-frequency power increased significantly). Meanwhile, the PPG parameters that represented sympathetic activity also increased (PPG amplitude and autonomic nervous system state significantly decreased). This study showed significant efficacy of RFT in patients with chronic cervical or lumbar pain. The changes of HRV and PPG parameters may explain part of the mechanisms of RFT. © 2016 World Institute of Pain.
Fonseca, Pedro; Weysen, Tim; Goelema, Maaike S; Møst, Els I S; Radha, Mustafa; Lunsingh Scheurleer, Charlotte; van den Heuvel, Leonie; Aarts, Ronald M
2017-07-01
To compare the accuracy of automatic sleep staging based on heart rate variability measured from photoplethysmography (PPG) combined with body movements measured with an accelerometer, with polysomnography (PSG) and actigraphy. Using wrist-worn PPG to analyze heart rate variability and an accelerometer to measure body movements, sleep stages and sleep statistics were automatically computed from overnight recordings. Sleep-wake, 4-class (wake/N1 + N2/N3/REM) and 3-class (wake/NREM/REM) classifiers were trained on 135 simultaneously recorded PSG and PPG recordings of 101 healthy participants and validated on 80 recordings of 51 healthy middle-aged adults. Epoch-by-epoch agreement and sleep statistics were compared with actigraphy for a subset of the validation set. The sleep-wake classifier obtained an epoch-by-epoch Cohen's κ between PPG and PSG sleep stages of 0.55 ± 0.14, sensitivity to wake of 58.2 ± 17.3%, and accuracy of 91.5 ± 5.1%. κ and sensitivity were significantly higher than with actigraphy (0.40 ± 0.15 and 45.5 ± 19.3%, respectively). The 3-class classifier achieved a κ of 0.46 ± 0.15 and accuracy of 72.9 ± 8.3%, and the 4-class classifier, a κ of 0.42 ± 0.12 and accuracy of 59.3 ± 8.5%. The moderate epoch-by-epoch agreement and, in particular, the good agreement in terms of sleep statistics suggest that this technique is promising for long-term sleep monitoring, although more evidence is needed to understand whether it can complement PSG in clinical practice. It also offers an improvement in sleep/wake detection over actigraphy for healthy individuals, although this must be confirmed on a larger, clinical population. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.
Pan, H; Huang, G P; Ren, R; Lei, F; Tang, X D
2016-05-24
To evaluate the diagnosis value of photoplethysmography (PPG)-based device for detecting obstructive sleep apnea syndrome. Patients who visited sleep medicine center in West China hospital from March 2014 to March 2015 with a main complain of snoring were selected into this study, and they were simultaneously monitored with the PPG-based device while undergoing polysomnography (PSG). Using PSG as"gold standard", the sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV) as well as corresponding areas under the receiver operator curves for an apnea hypopnea index (AHI) ≥5/h, ≥15/h and ≥30/h were calculated for PPG. Valid results were available for 93 subjects, among them there were 64 men and 29 women with a mean age of (44±13) years old.There were no significant difference between total sleep time, wake time after sleep onset, AHI and oxygen saturation derived by PPG and PSG.Positive correlation was found between PPG-derived and PSG-derived AHI (r=0.945). For AHI≥5/h, ≥15/h and ≥30/h respectively according PSG, sensitivity was 93%, 88%, 92%, specificity was 79%, 93%, 95%, PPV was 95%, 97%, 96%, NPV 75%, 76%, 91% for PPG. The corresponding areas under the receiver operator characteristic curves were 0.981, 0.996 and 0.995 respectively. PPG-derived data is consistent with simultaneous in-lab PSG in the diagnosis of obstructive sleep apnea syndrome.
Marston, William A
2002-03-01
Numerous noninvasive tests have been described for assistance in the diagnosis and treatment of patients with chronic venous insufficiency (CVI). These tests include venous duplex ultrasound examination in the supine and standing positions, photoplethysmography (PPG), and air plethysmography (APG). The goal of these studies is to provide accurate information describing the anatomic or the hemodynamic characteristics of the patient with CVI, precluding the need for invasive studies. These tests will be reviewed including the typical information obtained, the usefulness of this information, and the relevance for clinical management of patients with CVI. Based on the clinical class, recommendations for a noninvasive testing protocol are outlined. Copyright 2002 by W.B. Saunders Company
Evaluation of agreement between temporal series obtained from electrocardiogram and pulse wave.
NASA Astrophysics Data System (ADS)
Leikan, GM; Rossi, E.; Sanz, MCuadra; Delisle Rodríguez, D.; Mántaras, MC; Nicolet, J.; Zapata, D.; Lapyckyj, I.; Siri, L. Nicola; Perrone, MS
2016-04-01
Heart rate variability allows to study the cardiovascular autonomic nervous system modulation. Usually, this signal is obtained from the electrocardiogram (ECG). A simpler method for recording the pulse wave (PW) is by means of finger photoplethysmography (PPG), which also provides information about the duration of the cardiac cycle. In this study, the correlation and agreement between the time series of the intervals between heartbeats obtained from the ECG with those obtained from the PPG, were studied. Signals analyzed were obtained from young, healthy and resting subjects. For statistical analysis, the Pearson correlation coefficient and the Bland and Altman limits of agreement were used. Results show that the time series constructed from the PW would not replace the ones obtained from ECG.
Angle-selective optical filter for highly sensitive reflection photoplethysmogram
Hwang, Chan-Sol; Yang, Sung-Pyo; Jang, Kyung-Won; Park, Jung-Woo; Jeong, Ki-Hun
2017-01-01
We report an angle-selective optical filter (ASOF) for highly sensitive reflection photoplethysmography (PPG) sensors. The ASOF features slanted aluminum (Al) micromirror arrays embedded in transparent polymer resin, which effectively block scattered light under human tissue. The device microfabrication was done by using geometry-guided resist reflow of polymer micropatterns, polydimethylsiloxane replica molding, and oblique angle deposition of thin Al film. The angular transmittance through the ASOF is precisely controlled by the angle of micromirrors. For the mirror angle of 30 degrees, the ASOF accepts an incident light between - 90 to + 50 degrees and the maximum transmittance at - 55 degrees. The ASOF exhibits the substantial reduction of both the in-band noise of PPG signals over a factor of two and the low-frequency noise by three times. Consequently, this filter allows distinguishing the diastolic peak that allows miscellaneous parameters with diverse vascular information. This optical filter provides a new opportunity for highly sensitive PPG monitoring or miscellaneous optical tomography. PMID:29082070
Wearable PPG sensor based alertness scoring system.
Dey, Jishnu; Bhowmik, Tanmoy; Sahoo, Saswata; Tiwari, Vijay Narayan
2017-07-01
Quantifying mental alertness in today's world is important as it enables the person to adopt lifestyle changes for better work efficiency. Miniaturized sensors in wearable devices have facilitated detection/monitoring of mental alertness. Photoplethysmography (PPG) sensors through Heart Rate Variability (HRV) offer one such opportunity by providing information about one's daily alertness levels without requiring any manual interference from the user. In this paper, a smartwatch based alertness estimation system is proposed. Data collected from PPG sensor of smartwatch is processed and fed to machine learning based model to get a continuous alertness score. Utility functions are designed based on statistical analysis to give a quality score on different stages of alertness such as awake, long sleep and short duration power nap. An intelligent data collection approach is proposed in collaboration with the motion sensor in the smartwatch to reduce battery drainage. Overall, our proposed wearable based system provides a detailed analysis of alertness over a period in a systematic and optimized manner. We were able to achieve an accuracy of 80.1% for sleep/awake classification along with alertness score. This opens up the possibility for quantifying alertness levels using a single PPG sensor for better management of health related activities including sleep.
Advances in Photopletysmography Signal Analysis for Biomedical Applications.
Moraes, Jermana L; Rocha, Matheus X; Vasconcelos, Glauber G; Vasconcelos Filho, José E; de Albuquerque, Victor Hugo C; Alexandria, Auzuir R
2018-06-09
Heart Rate Variability (HRV) is an important tool for the analysis of a patient’s physiological conditions, as well a method aiding the diagnosis of cardiopathies. Photoplethysmography (PPG) is an optical technique applied in the monitoring of the HRV and its adoption has been growing significantly, compared to the most commonly used method in medicine, Electrocardiography (ECG). In this survey, definitions of these technique are presented, the different types of sensors used are explained, and the methods for the study and analysis of the PPG signal (linear and nonlinear methods) are described. Moreover, the progress, and the clinical and practical applicability of the PPG technique in the diagnosis of cardiovascular diseases are evaluated. In addition, the latest technologies utilized in the development of new tools for medical diagnosis are presented, such as Internet of Things, Internet of Health Things, genetic algorithms, artificial intelligence and biosensors which result in personalized advances in e-health and health care. After the study of these technologies, it can be noted that PPG associated with them is an important tool for the diagnosis of some diseases, due to its simplicity, its cost⁻benefit ratio, the easiness of signals acquisition, and especially because it is a non-invasive technique.
A novel feature ranking algorithm for biometric recognition with PPG signals.
Reşit Kavsaoğlu, A; Polat, Kemal; Recep Bozkurt, M
2014-06-01
This study is intended for describing the application of the Photoplethysmography (PPG) signal and the time domain features acquired from its first and second derivatives for biometric identification. For this purpose, a sum of 40 features has been extracted and a feature-ranking algorithm is proposed. This proposed algorithm calculates the contribution of each feature to biometric recognition and collocates the features, the contribution of which is from great to small. While identifying the contribution of the features, the Euclidean distance and absolute distance formulas are used. The efficiency of the proposed algorithms is demonstrated by the results of the k-NN (k-nearest neighbor) classifier applications of the features. During application, each 15-period-PPG signal belonging to two different durations from each of the thirty healthy subjects were used with a PPG data acquisition card. The first PPG signals recorded from the subjects were evaluated as the 1st configuration; the PPG signals recorded later at a different time as the 2nd configuration and the combination of both were evaluated as the 3rd configuration. When the results were evaluated for the k-NN classifier model created along with the proposed algorithm, an identification of 90.44% for the 1st configuration, 94.44% for the 2nd configuration, and 87.22% for the 3rd configuration has successfully been attained. The obtained results showed that both the proposed algorithm and the biometric identification model based on this developed PPG signal are very promising for contactless recognizing the people with the proposed method. Copyright © 2014 Elsevier Ltd. All rights reserved.
Accurate measurement of imaging photoplethysmographic signals based camera using weighted average
NASA Astrophysics Data System (ADS)
Pang, Zongguang; Kong, Lingqin; Zhao, Yuejin; Sun, Huijuan; Dong, Liquan; Hui, Mei; Liu, Ming; Liu, Xiaohua; Liu, Lingling; Li, Xiaohui; Li, Rongji
2018-01-01
Imaging Photoplethysmography (IPPG) is an emerging technique for the extraction of vital signs of human being using video recordings. IPPG technology with its advantages like non-contact measurement, low cost and easy operation has become one research hot spot in the field of biomedicine. However, the noise disturbance caused by non-microarterial area cannot be removed because of the uneven distribution of micro-arterial, different signal strength of each region, which results in a low signal noise ratio of IPPG signals and low accuracy of heart rate. In this paper, we propose a method of improving the signal noise ratio of camera-based IPPG signals of each sub-region of the face using a weighted average. Firstly, we obtain the region of interest (ROI) of a subject's face based camera. Secondly, each region of interest is tracked and feature-based matched in each frame of the video. Each tracked region of face is divided into 60x60 pixel block. Thirdly, the weights of PPG signal of each sub-region are calculated, based on the signal-to-noise ratio of each sub-region. Finally, we combine the IPPG signal from all the tracked ROI using weighted average. Compared with the existing approaches, the result shows that the proposed method takes modest but significant effects on improvement of signal noise ratio of camera-based PPG estimated and accuracy of heart rate measurement.
NASA Astrophysics Data System (ADS)
Marcinkevics, Z.; Rubins, U.; Caica, A.; Grabovskis, A.
2017-12-01
Assessment of skin microcirculation provides diagnostically valuable information during the early stages of pathologies. The simple, cost-effective and intrusive alternative to existing circulation assessment methods is remote photoplethysmography (rPPG). The objective of the present pilot study was to reveal an effect on sublingual administration of 1 mg nitroglycerin on systemic hemodynamic parameters and rPPG waveforms, at 810 nm and 530nm illumination. The protocol comprised 3 minutes of baseline recording, 15 minutes recording of NTG effect, 2 minutes of arterial occlusion and the following 3 min reactive hyperemia. Two PPG signals were acquired from glabrous skin of the middle finger distal phalange, consecutively at 530 nm and 810nm, 125 fps per channel, and systemic cardiovascular parameters were continuously registered in a beat-to-beat manner with a Finameter-midi system. The NTG effect was observed 0.7- 1.2 minutes post administration, reaching its maximum after 3 minutes. Systemic cardiovascular parameters significantly changed: mean arterial pressure decreased by 7.7+/-3.6%, total peripheral resistance by 10.5+/-9.0%, whereas the heart rate increased by 27.2+/-11.8%. Substantial alterations were observed for rPPG waveforms during NTG effect, decreasing reflection and stiffness indices. It has been concluded that rPPG waveform may provide information related to arterial stiffness, and could be potentially utilized in the clinics.
Adaptive cancellation of motion artifact in wearable biosensors.
Yousefi, Rasoul; Nourani, Mehrdad; Panahi, Issa
2012-01-01
The performance of wearable biosensors is highly influenced by motion artifact. In this paper, a model is proposed for analysis of motion artifact in wearable photoplethysmography (PPG) sensors. Using this model, we proposed a robust real-time technique to estimate fundamental frequency and generate a noise reference signal. A Least Mean Square (LMS) adaptive noise canceler is then designed and validated using our synthetic noise generator. The analysis and results on proposed technique for noise cancellation shows promising performance.
Becerra-Luna, Brayans; Martínez-Memije, Raúl; Cartas-Rosado, Raúl; Infante-Vázquez, Oscar
To improve the identification of peaks and feet in photoplethysmographic (PPG) pulses deformed by myokinetic noise, through the implementation of a modified fingertip and applying adaptive filtering. PPG signals were recordedfrom 10 healthy volunteers using two photoplethysmography systems placed on the index finger of each hand. Recordings lasted three minutes andwere done as follows: during the first minute, both handswere at rest, and for the lasting two minutes only the left hand was allowed to make quasi-periodicmovementsin order to add myokinetic noise. Two methodologies were employed to process the signals off-line. One consisted on using an adaptive filter based onthe Least Mean Square (LMS) algorithm, and the other includeda preprocessing stage in addition to the same LMS filter. Both filtering methods were compared and the one with the lowest error was chosen to assess the improvement in the identification of peaks and feet from PPG pulses. Average percentage errorsobtained wereof 22.94% with the first filtering methodology, and 3.72% withthe second one. On identifying peaks and feet from PPG pulsesbefore filtering, error percentages obtained were of 24.26% and 48.39%, respectively, and once filtered error percentageslowered to 2.02% for peaks and 3.77% for feet. The attenuation of myokinetic noise in PPG pulses through LMS filtering, plusa preprocessing stage, allows increasingthe effectiveness onthe identification of peaks and feet from PPG pulses, which are of great importance for medical assessment. Copyright © 2016 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.
Photoplethysmography: beyond the calculation of arterial oxygen saturation and heart rate.
Shelley, Kirk H
2007-12-01
In this article, I examine the source of the photoplethysmograph (PPG), as well as methods of investigation, with an emphasize on amplitude, rhythm, and pulse analysis. The PPG waveform was first described in the 1930s. Although considered an interesting ancillary monitor, the "pulse waveform" never underwent intensive investigation. Its importance in clinical medicine was greatly increased with the introduction of the pulse oximeter into routine clinical care in the 1980s. Its waveform is now commonly displayed in the clinical setting. Active research efforts are beginning to demonstrate a utility beyond oxygen saturation and heart rate determination. Future trends are being heavily influenced by modern digital signal processing, which is allowing a re-examination of this ubiquitous waveform. Key to unlocking the potential of this waveform is an unfettered access to the raw signal, combined with standardization of its presentation, and methods of analysis. In the long run, we need to learn how to consistently quantify the characteristics of the PPG in such a way as to allow the results from research efforts be translated into clinically useful devices.
A low-power high-sensitivity analog front-end for PPG sensor.
Binghui Lin; Atef, Mohamed; Guoxing Wang
2017-07-01
This paper presents a low-power analog front-end (AFE) photoplethysmography (PPG) sensor fabricated in 0.35 μm CMOS process. The AFE amplifies the weak photocurrent from the photodiode (PD) and converts it to a strong voltage at the output. In order to decrease the power consumption, the circuits are designed in subthreshold region; so the total biasing current of the AFE is 10 μ A. Since the large input DC photocurrent is a big issue for the PPG sensing circuit, we apply a DC photocurrent rejection technique by adding a DC current-cancellation loop to reject the large DC photocurrent up to 10 μA. In addition, a pseudo resistor is used to reduce the high-pass corner frequency below 0.5 Hz and Gm-C filter is adapted to reject the out-of-band noise higher than 16 Hz. For the whole sensor, the amplifier chain can achieve a total gain of 140 dBμ and an input integrated noise current of 68.87 pA rms up to 16 Hz.
Sandberg, M; Zhang, Q; Styf, J; Gerdle, B; Lindberg, L-G
2005-04-01
To evaluate a specially developed photoplethysmographic (PPG) technique, using green and near-infrared light sources, for simultaneous non-invasive monitoring of skin and muscle perfusion. Evaluation was based on assessments of changes in blood perfusion to various provocations, such as post-exercise hyperaemia and hyperaemia following the application of liniment. The deep penetrating feature of PPG was investigated by measurement of optical radiation inside the muscle. Simultaneous measurements using ultrasound Doppler and the new PPG application were performed to elucidate differences between the two methods. Specific problems related to the influence of skin temperature on blood flow were highlightened, as well. Following static and dynamic contractions an immediate increase in muscle perfusion was shown, without increase in skin perfusion. Liniment application to the skin induced a rapid increase in skin perfusion, but not in muscle. Both similarities and differences in blood flow measured by Ultrasound Doppler and PPG were demonstrated. The radiant power measured inside the muscle, by use of an optical fibre, showed that the near-infrared light penetrates down to the vascular depth inside the muscle. The results of this study indicate the potentiality of the method for non-invasive measurement of local muscle perfusion, although some considerations still have to be accounted for, such as influence of temperature on blood perfusion.
Non-contact method of search and analysis of pulsating vessels
NASA Astrophysics Data System (ADS)
Avtomonov, Yuri N.; Tsoy, Maria O.; Postnov, Dmitry E.
2018-04-01
Despite the variety of existing methods of recording the human pulse and a solid history of their development, there is still considerable interest in this topic. The development of new non-contact methods, based on advanced image processing, caused a new wave of interest in this issue. We present a simple but quite effective method for analyzing the mechanical pulsations of blood vessels lying close to the surface of the skin. Our technique is a modification of imaging (or remote) photoplethysmography (i-PPG). We supplemented this method with the addition of a laser light source, which made it possible to use other methods of searching for the proposed pulsation zone. During the testing of the method, several series of experiments were carried out with both artificial oscillating objects as well as with the target signal source (human wrist). The obtained results show that our method allows correct interpretation of complex data. To summarize, we proposed and tested an alternative method for the search and analysis of pulsating vessels.
Peláez-Coca, M. D.; Orini, M.; Lázaro, J.; Bailón, R.; Gil, E.
2013-01-01
A methodology that combines information from several nonstationary biological signals is presented. This methodology is based on time-frequency coherence, that quantifies the similarity of two signals in the time-frequency domain. A cross time-frequency analysis method, based on quadratic time-frequency distribution, has been used for combining information of several nonstationary biomedical signals. In order to evaluate this methodology, the respiratory rate from the photoplethysmographic (PPG) signal is estimated. The respiration provokes simultaneous changes in the pulse interval, amplitude, and width of the PPG signal. This suggests that the combination of information from these sources will improve the accuracy of the estimation of the respiratory rate. Another target of this paper is to implement an algorithm which provides a robust estimation. Therefore, respiratory rate was estimated only in those intervals where the features extracted from the PPG signals are linearly coupled. In 38 spontaneous breathing subjects, among which 7 were characterized by a respiratory rate lower than 0.15 Hz, this methodology provided accurate estimates, with the median error {0.00; 0.98} mHz ({0.00; 0.31}%) and the interquartile range error {4.88; 6.59} mHz ({1.60; 1.92}%). The estimation error of the presented methodology was largely lower than the estimation error obtained without combining different PPG features related to respiration. PMID:24363777
Fischer, Christoph; Domer, Benno; Wibmer, Thomas; Penzel, Thomas
2017-03-01
Photoplethysmography has been used in a wide range of medical devices for measuring oxygen saturation, cardiac output, assessing autonomic function, and detecting peripheral vascular disease. Artifacts can render the photoplethysmogram (PPG) useless. Thus, algorithms capable of identifying artifacts are critically important. However, the published PPG algorithms are limited in algorithm and study design. Therefore, the authors developed a novel embedded algorithm for real-time pulse waveform (PWF) segmentation and artifact detection based on a contour analysis in the time domain. This paper provides an overview about PWF and artifact classifications, presents the developed PWF analysis, and demonstrates the implementation on a 32-bit ARM core microcontroller. The PWF analysis was validated with data records from 63 subjects acquired in a sleep laboratory, ergometry laboratory, and intensive care unit in equal parts. The output of the algorithm was compared with harmonized experts' annotations of the PPG with a total duration of 31.5 h. The algorithm achieved a beat-to-beat comparison sensitivity of 99.6%, specificity of 90.5%, precision of 98.5%, and accuracy of 98.3%. The interrater agreement expressed as Cohen's kappa coefficient was 0.927 and as F-measure was 0.990. In conclusion, the PWF analysis seems to be a suitable method for PPG signal quality determination, real-time annotation, data compression, and calculation of additional pulse wave metrics such as amplitude, duration, and rise time.
Heart rate sensitive optical coherence angiography
NASA Astrophysics Data System (ADS)
Alvarez, Karl; Lopez-Tremoleda, Jordi; Donnan, Rob; Michael-Titus, Adina T.; Tomlins, Peter H.
2018-02-01
Optical coherence angiography (OCA) enables visualisation of three-dimensional micro-vasculature from optical coherence tomography data volumes. Typically, various statistical methods are used to discriminate static tissue from blood flow within vessels. In this paper, we introduce a new method that relies upon the beating heart frequency to isolate blood vessels from the surrounding tissue. Vascular blood flow is assumed to be more strongly modulated by the heart-beat compared to surrounding tissue and therefore short-time Fourier transform of sequential measurements can discriminate the two. Furthermore, it is demonstrated that adjacent B-Scans within an OCT data volume can provide the required sampling frequency. As such, the technique can be considered to be a spatially mapped variation of photoplethysmography (PPG), whereby each image voxel operates as a PPG detector. This principle is demonstrated using both a model system and in vivo for monitoring the vascular changes effected by traumatic brain injury in mice. In vivo measurements were acquired at an A-Scan rate of 10kHz to form a 500x500x512 (lateral x lateral x axial) pixel volume, enabling sequential sampling of the mouse heart rate in an expected range of 300-600 bpm. One of the advantages of this new OCA processing method is that it can be used in conjunction with existing algorithms as an additional filter for signal to noise enhancement.
Gao, Mingwu; Olivier, N Bari; Mukkamala, Ramakrishna
2016-05-01
Pulse transit time (PTT) measured as the time delay between invasive proximal and distal blood pressure (BP) or flow waveforms (invasive PTT [I-PTT]) tightly correlates with BP PTT estimated as the time delay between noninvasive proximal and distal arterial waveforms could therefore permit cuff-less BP monitoring. A popular noninvasive PTT estimate for this application is the time delay between ECG and photoplethysmography (PPG) waveforms (pulse arrival time [PAT]). Another estimate is the time delay between proximal and distal PPG waveforms (PPG-PTT). PAT and PPG-PTT were assessed as markers of BP over a wide physiologic range using I-PTT as a reference. Waveforms for determining I-PTT, PAT, and PPG-PTT through central arteries were measured from swine during baseline conditions and infusions of various hemodynamic drugs. Diastolic, mean, and systolic BP varied widely in each subject (group average (mean ± SE) standard deviation between 25 ± 2 and 36 ± 2 mmHg). I-PTT correlated well with all BP levels (group average R(2) values between 0.86 ± 0.03 and 0.91 ± 0.03). PPG-PTT also correlated well with all BP levels (group average R(2) values between 0.81 ± 0.03 and 0.85 ± 0.02), and its R(2) values were not significantly different from those of I-PTT PAT correlated best with systolic BP (group average R(2) value of 0.70 ± 0.04), but its R(2) values for all BP levels were significantly lower than those of I-PTT (P < 0.005) and PPG-PTT (P < 0.02). The pre-ejection period component of PAT was responsible for its inferior correlation with BP In sum, PPG-PTT was not different from I-PTT and superior to the popular PAT as a marker of BP. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.
Novel Signal Noise Reduction Method through Cluster Analysis, Applied to Photoplethysmography.
Waugh, William; Allen, John; Wightman, James; Sims, Andrew J; Beale, Thomas A W
2018-01-01
Physiological signals can often become contaminated by noise from a variety of origins. In this paper, an algorithm is described for the reduction of sporadic noise from a continuous periodic signal. The design can be used where a sample of a periodic signal is required, for example, when an average pulse is needed for pulse wave analysis and characterization. The algorithm is based on cluster analysis for selecting similar repetitions or pulses from a periodic single. This method selects individual pulses without noise, returns a clean pulse signal, and terminates when a sufficiently clean and representative signal is received. The algorithm is designed to be sufficiently compact to be implemented on a microcontroller embedded within a medical device. It has been validated through the removal of noise from an exemplar photoplethysmography (PPG) signal, showing increasing benefit as the noise contamination of the signal increases. The algorithm design is generalised to be applicable for a wide range of physiological (physical) signals.
Can PPG be used for HRV analysis?
Pinheiro, N; Couceiro, R; Henriques, J; Muehlsteff, J; Quintal, I; Goncalves, L; Carvalho, P
2016-08-01
Heart rate variability (HRV) represents one of the most promising markers of the autonomic nervous system (ANS) regulation. However, it requires the acquisition of the ECG signal in order to reliably detect the RR intervals, which is not always easily and comfortably available in personal health applications. Additionally, due to progress in single spot optical sensors, photoplethysmography (PPG) is an interesting alternative for heartbeat interval measurements, since it is a more convenient and a less intrusive measurement technique. Driven by the technological advances in such sensors, wrist-worn devices are becoming a commodity, and the interest in the assessment of HRV indexes from the PPG analysis (pulse rate variability - PRV) is rising. In this study, we investigate the hypothesis of using PRV features as surrogates for HRV indexes, in three different contexts: healthy subjects at rest, healthy subjects after physical exercise and subjects with cardiovascular diseases (CVD). Additionally, we also evaluate which are the characteristic points better suited for PRV analysis in these contexts, i.e. the PPG waveform characteristic points leading to the PRV features that present the best estimates of HRV (correlation and error analysis). The achieved results suggest that the PRV can be often used as an alternative for HRV analysis in healthy subjects, with significant correlations above 82%, for both time and frequency features. Contrarily, in the post-exercise and CVD subjects, time and (most importantly) frequency domain features shall be used with caution (mean correlations ranging from 68% to 88%).
NASA Astrophysics Data System (ADS)
Humphreys, Kenneth; Ward, Tomas; Markham, Charles
2007-04-01
We present a camera-based device capable of capturing two photoplethysmographic (PPG) signals at two different wavelengths simultaneously, in a remote noncontact manner. The system comprises a complementary metal-oxide semiconductor camera and dual wavelength array of light emitting diodes (760 and 880nm). By alternately illuminating a region of tissue with each wavelength of light, and detecting the backscattered photons with the camera at a rate of 16frames/wavelengths, two multiplexed PPG wave forms are simultaneously captured. This process is the basis of pulse oximetry, and we describe how, with the inclusion of a calibration procedure, this system could be used as a noncontact pulse oximeter to measure arterial oxygen saturation (SpO2) remotely. Results from an experiment on ten subjects, exhibiting normal SpO2 readings, that demonstrate the instrument's ability to capture signals from a range of subjects under realistic lighting and environmental conditions are presented. We compare the signals captured by the noncontact system to a conventional PPG signal captured concurrently from a finger, and show by means of a J. Bland and D. Altman [Lancet 327, 307 (1986); Statistician 32, 307 (1983)] test, the noncontact device to be comparable to a contact device as a monitor of heart rate. We highlight some considerations that should be made when using camera-based "integrative" sampling methods and demonstrate through simulation, the suitability of the captured PPG signals for application of existing pulse oximetry calibration procedures.
Diagnosis of obstructive sleep apnea using pulse oximeter derived photoplethysmographic signals.
Romem, Ayal; Romem, Anat; Koldobskiy, Dafna; Scharf, Steven M
2014-03-15
Increasing awareness of the high prevalence of obstructive sleep apnea (OSA) and its impact on health in conjunction with high cost, inconvenience, and short supply of in-lab polysomnography (PSG) has led to the development of more convenient, affordable, and accessible diagnostic devices. We evaluated the reliability and accuracy of a single-channel (finger pulse-oximetry) photoplethysmography (PPG)-based device for detection of OSA (Morpheus Ox). Among a cohort of 73 patients referred for in-laboratory evaluation of OSA, 65 were simultaneously monitored with the PPG based device while undergoing PSG. Among these, 19 had significant cardiopulmonary comorbidities. Using the PSG as the "gold standard," the sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), as well as the positive likelihood ratio (+LR) for an apnea hypopnea index (AHI)PSG > 5/h and AHIPSG > 15/h were calculated for the PPG. Valid results were available for 65 subjects. Mean age: 52.1 ± 14.2, Male: 52%, and BMI: 36.3 ± 9.7 kg/m(2). Positive correlation was found between PPG-derived and PSG-derived AHI (r = 0.81, p < 0.001). For AHIPSG > 5/h, sensitivity was 80%, specificity 86%, PPV 93%, NPV 68%, and +LR was 5.9. For AHIPSG > 15/h, sensitivity was 70%, specificity 91%, PPV 80%, NPV 85%, and +LR was 7.83. The corresponding areas under the receiver operator curves were 0.91 and 0.9. PPG-derived data compare well with simultaneous in-lab PSG in the diagnosis of suspected OSA among patients with and without cardiopulmonary comorbidities. Romem A; Romem A; Koldobskiy D; Scharf SM. Diagnosis of obstructive sleep apnea using pulse oximeter derived photoplethysmographic signals.
Wu, Hau-Tieng; Lewis, Gregory F; Davila, Maria I; Daubechies, Ingrid; Porges, Stephen W
2016-10-17
With recent advances in sensor and computer technologies, the ability to monitor peripheral pulse activity is no longer limited to the laboratory and clinic. Now inexpensive sensors, which interface with smartphones or other computer-based devices, are expanding into the consumer market. When appropriate algorithms are applied, these new technologies enable ambulatory monitoring of dynamic physiological responses outside the clinic in a variety of applications including monitoring fatigue, health, workload, fitness, and rehabilitation. Several of these applications rely upon measures derived from peripheral pulse waves measured via contact or non-contact photoplethysmography (PPG). As technologies move from contact to non-contact PPG, there are new challenges. The technology necessary to estimate average heart rate over a few seconds from a noncontact PPG is available. However, a technology to precisely measure instantaneous heat rate (IHR) from non-contact sensors, on a beat-to-beat basis, is more challenging. The objective of this paper is to develop an algorithm with the ability to accurately monitor IHR from peripheral pulse waves, which provides an opportunity to measure the neural regulation of the heart from the beat-to-beat heart rate pattern (i.e., heart rate variability). The adaptive harmonic model is applied to model the contact or non-contact PPG signals, and a new methodology, the Synchrosqueezing Transform (SST), is applied to extract IHR. The body sway rhythm inherited in the non-contact PPG signal is modeled and handled by the notion of wave-shape function. The SST optimizes the extraction of IHR from the PPG signals and the technique functions well even during periods of poor signal to noise. We contrast the contact and non-contact indices of PPG derived heart rate with a criterion electrocardiogram (ECG). ECG and PPG signals were monitored in 21 healthy subjects performing tasks with different physical demands. The root mean square error of IHR estimated by SST is significantly better than commonly applied methods such as autoregressive (AR) method. In the walking situation, while AR method fails, SST still provides a reasonably good result. The SST processed PPG data provided an accurate estimate of the ECG derived IHR and consistently performed better than commonly applied methods such as autoregressive method.
Development of HIHM (Home Integrated Health Monitor) for ubiquitous home healthcare.
Kim, Jung Soo; Kim, Beom Oh; Park, Kwang Suk
2007-01-01
Home Integrated Health Monitor (HIHM) was developed for ubiquitous home healthcare. From quantitative analysis, we have elicited modal of chair. The HIHM could detect Electrocardiogram (ECG) and Photoplethysmography (PPG) non-intrusively. Also, it could estimate blood pressure (BP) non-intrusively, measure blood glucose and ear temperature. Detected signals and information were transmitted to home gateway and home server through Zigbee communication technology. Home server carried them to Healthcare Center, and specialists such as medical doctors could monitor by Internet. There was also feedback system. This device has a potential to study about ubiquitous home healthcare.
IEEE-802.15.4-based low-power body sensor node with RF energy harvester.
Tran, Thang Viet; Chung, Wan-Young
2014-01-01
This paper proposes the design and implementation of a low-voltage and low-power body sensor node based on the IEEE 802.15.4 standard to collect electrocardiography (ECG) and photoplethysmography (PPG) signals. To achieve compact size, low supply voltage, and low power consumption, the proposed platform is integrated into a ZigBee mote, which contains a DC-DC booster, a PPG sensor interface module, and an ECG front-end circuit that has ultra-low current consumption. The input voltage of the proposed node is very low and has a wide range, from 0.65 V to 3.3 V. An RF energy harvester is also designed to charge the battery during the working mode or standby mode of the node. The power consumption of the proposed node reaches 14 mW in working mode to prolong the battery lifetime. The software is supported by the nesC language under the TinyOS environment, which enables the proposed node to be easily configured to function as an individual health monitoring node or a node in a wireless body sensor network (BSN). The proposed node is used to set up a wireless BSN that can simultaneously collect ECG and PPG signals and monitor the results on the personal computer.
Guede-Fernandez, F; Ferrer-Mileo, V; Ramos-Castro, J; Fernandez-Chimeno, M; Garcia-Gonzalez, M A
2015-01-01
The aim of this paper is to present a smartphone based system for real-time pulse-to-pulse (PP) interval time series acquisition by frame-to-frame camera image processing. The developed smartphone application acquires image frames from built-in rear-camera at the maximum available rate (30 Hz) and the smartphone GPU has been used by Renderscript API for high performance frame-by-frame image acquisition and computing in order to obtain PPG signal and PP interval time series. The relative error of mean heart rate is negligible. In addition, measurement posture and the employed smartphone model influences on the beat-to-beat error measurement of heart rate and HRV indices have been analyzed. Then, the standard deviation of the beat-to-beat error (SDE) was 7.81 ± 3.81 ms in the worst case. Furthermore, in supine measurement posture, significant device influence on the SDE has been found and the SDE is lower with Samsung S5 than Motorola X. This study can be applied to analyze the reliability of different smartphone models for HRV assessment from real-time Android camera frames processing.
Chan, Christy KY; Li, Christien KH; To, Olivia TL; Lai, William HS; Tse, Gary; Poh, Yukkee C; Poh, Ming-Zher
2017-01-01
Background Modern smartphones allow measurement of heart rate (HR) by detecting pulsatile photoplethysmographic (PPG) signals with built-in cameras from the fingertips or the face, without physical contact, by extracting subtle beat-to-beat variations of skin color. Objective The objective of our study was to evaluate the accuracy of HR measurements at rest and after exercise using a smartphone-based PPG detection app. Methods A total of 40 healthy participants (20 men; mean age 24.7, SD 5.2 years; von Luschan skin color range 14-27) underwent treadmill exercise using the Bruce protocol. We recorded simultaneous PPG signals for each participant by having them (1) facing the front camera and (2) placing their index fingertip over an iPhone’s back camera. We analyzed the PPG signals from the Cardiio-Heart Rate Monitor + 7 Minute Workout (Cardiio) smartphone app for HR measurements compared with a continuous 12-lead electrocardiogram (ECG) as the reference. Recordings of 20 seconds’ duration each were acquired at rest, and immediately after moderate- (50%-70% maximum HR) and vigorous- (70%-85% maximum HR) intensity exercise, and repeated successively until return to resting HR. We used Bland-Altman plots to examine agreement between ECG and PPG-estimated HR. The accuracy criterion was root mean square error (RMSE) ≤5 beats/min or ≤10%, whichever was greater, according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation EC-13 standard. Results We analyzed a total of 631 fingertip and 626 facial PPG measurements. Fingertip PPG-estimated HRs were strongly correlated with resting ECG HR (r=.997, RMSE=1.03 beats/min or 1.40%), postmoderate-intensity exercise (r=.994, RMSE=2.15 beats/min or 2.53%), and postvigorous-intensity exercise HR (r=.995, RMSE=2.01 beats/min or 1.93%). The correlation of facial PPG-estimated HR was stronger with resting ECG HR (r=.997, RMSE=1.02 beats/min or 1.44%) than with postmoderate-intensity exercise (r=.982, RMSE=3.68 beats/min or 4.11%) or with postvigorous-intensity exercise (r=.980, RMSE=3.84 beats/min or 3.73%). Bland-Altman plots showed better agreement between ECG and fingertip PPG-estimated HR than between ECG and facial PPG-estimated HR. Conclusions We found that HR detection by the Cardiio smartphone app was accurate at rest and after moderate- and vigorous-intensity exercise in a healthy young adult sample. Contact-free facial PPG detection is more convenient but is less accurate than finger PPG due to body motion after exercise. PMID:28288955
Non-contact cardiac pulse rate estimation based on web-camera
NASA Astrophysics Data System (ADS)
Wang, Yingzhi; Han, Tailin
2015-12-01
In this paper, we introduce a new methodology of non-contact cardiac pulse rate estimation based on the imaging Photoplethysmography (iPPG) and blind source separation. This novel's approach can be applied to color video recordings of the human face and is based on automatic face tracking along with blind source separation of the color channels into RGB three-channel component. First of all, we should do some pre-processings of the data which can be got from color video such as normalization and sphering. We can use spectrum analysis to estimate the cardiac pulse rate by Independent Component Analysis (ICA) and JADE algorithm. With Bland-Altman and correlation analysis, we compared the cardiac pulse rate extracted from videos recorded by a basic webcam to a Commercial pulse oximetry sensors and achieved high accuracy and correlation. Root mean square error for the estimated results is 2.06bpm, which indicates that the algorithm can realize the non-contact measurements of cardiac pulse rate.
Yan, Bryan P; Chan, Christy Ky; Li, Christien Kh; To, Olivia Tl; Lai, William Hs; Tse, Gary; Poh, Yukkee C; Poh, Ming-Zher
2017-03-13
Modern smartphones allow measurement of heart rate (HR) by detecting pulsatile photoplethysmographic (PPG) signals with built-in cameras from the fingertips or the face, without physical contact, by extracting subtle beat-to-beat variations of skin color. The objective of our study was to evaluate the accuracy of HR measurements at rest and after exercise using a smartphone-based PPG detection app. A total of 40 healthy participants (20 men; mean age 24.7, SD 5.2 years; von Luschan skin color range 14-27) underwent treadmill exercise using the Bruce protocol. We recorded simultaneous PPG signals for each participant by having them (1) facing the front camera and (2) placing their index fingertip over an iPhone's back camera. We analyzed the PPG signals from the Cardiio-Heart Rate Monitor + 7 Minute Workout (Cardiio) smartphone app for HR measurements compared with a continuous 12-lead electrocardiogram (ECG) as the reference. Recordings of 20 seconds' duration each were acquired at rest, and immediately after moderate- (50%-70% maximum HR) and vigorous- (70%-85% maximum HR) intensity exercise, and repeated successively until return to resting HR. We used Bland-Altman plots to examine agreement between ECG and PPG-estimated HR. The accuracy criterion was root mean square error (RMSE) ≤5 beats/min or ≤10%, whichever was greater, according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation EC-13 standard. We analyzed a total of 631 fingertip and 626 facial PPG measurements. Fingertip PPG-estimated HRs were strongly correlated with resting ECG HR (r=.997, RMSE=1.03 beats/min or 1.40%), postmoderate-intensity exercise (r=.994, RMSE=2.15 beats/min or 2.53%), and postvigorous-intensity exercise HR (r=.995, RMSE=2.01 beats/min or 1.93%). The correlation of facial PPG-estimated HR was stronger with resting ECG HR (r=.997, RMSE=1.02 beats/min or 1.44%) than with postmoderate-intensity exercise (r=.982, RMSE=3.68 beats/min or 4.11%) or with postvigorous-intensity exercise (r=.980, RMSE=3.84 beats/min or 3.73%). Bland-Altman plots showed better agreement between ECG and fingertip PPG-estimated HR than between ECG and facial PPG-estimated HR. We found that HR detection by the Cardiio smartphone app was accurate at rest and after moderate- and vigorous-intensity exercise in a healthy young adult sample. Contact-free facial PPG detection is more convenient but is less accurate than finger PPG due to body motion after exercise. ©Bryan P Yan, Christy KY Chan, Christien KH Li, Olivia TL To, William HS Lai, Gary Tse, Yukkee C Poh, Ming-Zher Poh. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 13.03.2017.
Huberman, Jackie S; Dawson, Samantha J; Chivers, Meredith L
2017-10-01
Sexual response is a dynamic process, though there is limited knowledge of the time course and relationships among its psychological and physiological components. To address this gap, we concurrently assessed self-reported sexual arousal, genital temperature (with thermography), and genital vasocongestion (with vaginal photoplethysmography [VPP] or penile plethysmography [PPG]) during sexual and nonsexual films in 28 androphilic women (attracted to men) and 27 gynephilic men (attracted to women). Men and women had similarly strong agreement between subjective and genital responses (sexual concordance) with thermography, but this agreement was stronger in men than women with PPG/VPP. The time course of changes in self-reported arousal was most similar to changes in genital temperature (i.e., time to onset and peak response). Time-lagged correlations and multilevel modeling revealed changes in the strength of relationships between aspects of sexual response over time. Results highlight the dynamic nature of sexual response and drawbacks of relying on zero-order correlations to characterize sexual concordance. Copyright © 2017 Elsevier B.V. All rights reserved.
Spot measurement of heart rate based on morphology of PhotoPlethysmoGraphic (PPG) signals.
Madhan Mohan, P; Nagarajan, V; Vignesh, J C
2017-02-01
Due to increasing health consciousness among people, it is imperative to have low-cost health care devices to measure the vital parameters like heart rate and arterial oxygen saturation (SpO 2 ). In this paper, an efficient heart rate monitoring algorithm based on the morphology of photoplethysmography (PPG) signals to measure the spot heart rate (HR) and its real-time implementation is proposed. The algorithm does pre-processing and detects the onsets and systolic peaks of the PPG signal to estimate the heart rate of the subject. Since the algorithm is based on the morphology of the signal, it works well when the subject is not moving, which is a typical test case. So, this algorithm is developed mainly to measure the heart rate at on-demand applications. Real-time experimental results indicate the heart rate accuracy of 99.5%, mean absolute percentage error (MAPE) of 1.65%, mean absolute error (MAE) of 1.18 BPM and reference closeness factor (RCF) of 0.988. The results further show that the average response time of the algorithm to give the spot HR is 6.85 s, so that the users need not wait longer to see their HR. The hardware implementation results show that the algorithm only requires 18 KBytes of total memory and runs at high speed with 0.85 MIPS. So, this algorithm can be targeted to low-cost embedded platforms.
Wave detection in acceleration plethysmogram.
Ahn, Jae Mok
2015-04-01
Acceleration plethysmogram (APG) obtained from the second derivative of photoplethysmography (PPG) is used to predict risk factors for atherosclerosis with age. This technique is promising for early screening of atherosclerotic pathologies. However, extraction of the wave indices of APG signals measured from the fingertip is challenging. In this paper, the development of a wave detection algorithm including a preamplifier based on a microcontroller that can detect the a, b, c, and d wave indices is proposed. The 4(th) order derivative of a PPG under real measurements of an APG waveform was introduced to clearly separate the components of the waveform, and to improve the rate of successful wave detection. A preamplifier with a Sallen-Key low pass filter and a wave detection algorithm with programmable gain control, mathematical differentials, and a digital IIR notch filter were designed. The frequency response of the digital IIR filter was evaluated, and a pulse train consisting of a specific area in which the wave indices existed was generated. The programmable gain control maintained a constant APG amplitude at the output for varying PPG amplitudes. For 164 subjects, the mean values and standard deviation of the a wave index corresponding to the magnitude of the APG signal were 1,106.45 and ±47.75, respectively. We conclude that the proposed algorithm and preamplifier designed to extract the wave indices of an APG in real-time are useful for evaluating vascular aging in the cardiovascular system in a simple healthcare device.
Mukherjee, Ramtanu; Ghosh, Sanchita; Gupta, Bharat; Chakravarty, Tapas
2018-01-22
The effectiveness of any remote healthcare monitoring system depends on how much accurate, patient-friendly, versatile, and cost-effective measurement it is delivering. There has always been a huge demand for such a long-term noninvasive remote blood pressure (BP) measurement system, which could be used worldwide in the remote healthcare industry. Thus, noninvasive continuous BP measurement and remote monitoring have become an emerging area in the remote healthcare industry. Photoplethysmography-based (PPG) BP measurement is a continuous, unobtrusive, patient-friendly, and cost-effective solution. However, BP measurements through PPG sensors are not much reliable and accurate due to some major limitations like pressure disturbance, motion artifacts, and variations in human skin tone. A novel reflective PPG sensor has been developed to eliminate the abovementioned pressure disturbance and motion artifacts during the BP measurement. Considering the variations of the human skin tone across demography, a novel algorithm has been developed to make the BP measurement accurate and reliable. The training dataset captured 186 subjects' data and the trial dataset captured another new 102 subjects' data. The overall accuracy achieved by using the proposed method is nearly 98%. Thus, demonstrating the efficacy of the proposed method. The developed BP monitoring system is quite accurate, reliable, cost-effective, handy, and user friendly. It is also expected that this system would be quite useful to monitor the BP of infants, elderly people, patients having wounds, burn injury, or in the intensive care unit environment.
Darvall, K A L; Sam, R C; Bate, G R; Adam, D J; Silverman, S H; Bradbury, A W
2010-08-01
Digital photoplethysmography (PPG) provides an inexpensive, reproducible, quantitative, non-invasive assessment of lower limb venous function. To examine the relationship between venous refilling time (VRT) and severity of venous disease, and also between changes in VRT and symptomatic improvement after ultrasound guided foam sclerotherapy (UGFS) for symptomatic superficial venous reflux (SVR). Prior to and 6 months after UGFS, 246 patients (317 limbs) completed a symptom questionnaire, underwent duplex ultrasonography and clinical assessment, and VRT measurement by digital PPG. Health related quality of life (HRQL) questionnaires were also completed. Median VRT improved from 11 to 31 s (P < 0.0005, Wilcoxon Signed Ranks). Abnormal VRT (<20 s) correlated well with the presence of SVR on duplex (sensitivity 75%, specificity 94%). Pre-treatment there was a significant relationship between reducing VRT and increasing CEAP clinical grade (P < 0.0005, chi(2)), extent of SVR on duplex (P < 0.0005) and a non-significant relationship with overall increasing symptom severity (P = 0.097). Relief of all symptoms was more likely when there was normalisation of VRT after treatment (80% vs. 65%, P < 0.0005, chi(2)). Pre-treatment VRT correlated with both generic physical (r = 0.428, P = 0.002) and disease-specific (r = -0.413, P = 0.003, Spearman's rank) HRQL. UGFS for SVR improves VRT measured by digital PPG and that improvement correlates with symptom relief. Copyright (c) 2010 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Vital physical signals measurements using a webcam
NASA Astrophysics Data System (ADS)
Ouyang, Jianfei; Yan, Yonggang; Yao, Lifeng
2013-10-01
Non-contact and remote measurements of vital physical signals are important for reliable and comfortable physiological self-assessment. In this paper, we provide a new video-based methodology for remote and fast measurements of vital physical signals such as cardiac pulse and breathing rate. A webcam is used to track color video of a human face or wrist, and a Photoplethysmography (PPG) technique is applied to perform the measurements of the vital signals. A novel sequential blind signal extraction methodology is applied to the color video under normal lighting conditions, based on correlation analysis between the green trace and the source signals. The approach is successfully applied in the measurement of vital signals under the condition of different illuminating in which the target signal can also be found out accurately. To assess the advantages, the measuring time of a large number of cases is recorded correctly. The experimental results show that it only takes less than 30 seconds to measure the vital physical signals using presented technique. The study indicates the proposed approach is feasible for PPG technique, which provides a way to study the relationship of the signal for different ROI in future research.
NASA Astrophysics Data System (ADS)
van Gastel, Mark; Balmaekers, Benoît; Bambang Oetomo, Sidarto; Verkruysse, Wim
2018-02-01
Currently, the cardiac activity of infants in the Neonatal Intensive Care Unit (NICU) is monitored with contact sensors. These techniques can cause injuries and infections, particularly in very premature infants with fragile skin. Recently, remote photoplethysmography (rPPG) showed its potential to measure cardiac activity with a camera without skin contact. The main limitations of this technique are its lack of robustness to subject motion and visible light requirements. The aim of this study is to investigate the feasibility of robust rPPG for NICU patients in near darkness. Video recordings using dedicated infrared illumination were made of 7 infants, age 30-33 weeks, at a NICU in Eindhoven, The Netherlands. The pulse rate can be detected with an average error of 1.5 BPM and 2.1 BPM when measured at the face and upper torso region, respectively. Overall, the correct pulse rate is detected for 87% of the time. A camera-based framework for robust pulse extraction in near darkness of NICU patients was proposed and successfully validated. The pulse rate could be reliably detected from all evaluated skin regions. Recordings with vigorous body movements, involving occlusion of the selected skin region, are still a challenge.
Glass-type wireless PPG measuring system.
Lee, E M; Shin, J Y; Hong, J H; Cha, E J; Lee, T S
2010-01-01
This paper is about a glass-type wireless bio-signal transmitter that can monitor the user's health state in daily life. The device implemented in this study consists of the transmission part and the receiving part. The transmission part includes a photoplethysmography(PPG) sensor for detecting pulse wave signals, accelerometer for detecting kinetic signals, and a wireless controller for transmitting acquired bio-information. The receiving part is designed to check and process transmitted data through interoperation with a PC. In the experiments, we collected data during a sitting posture and repeated sit-to-stand motion in laboratory environment, and analyzed the data. As to accuracy, the correlation between the peak-to-peak intervals in the signals of the Biopac equipment and the developed device measured in a sitting posture was 97.5%, and that measured in sit-to-stand motion was 87%. In addition, when bio-signals were transmitted through wireless communication, the transmission was successful 100% without any error. When pulse wave signals and kinetic signals were obtained and compared, the results proved the accuracy and daily applicability of the developed device, and the glass-type wireless bio-signal transmission system is expected to be applicable to unobtrusive health monitoring for the user.
Optimization of wireless Bluetooth sensor systems.
Lonnblad, J; Castano, J; Ekstrom, M; Linden, M; Backlund, Y
2004-01-01
Within this study, three different Bluetooth sensor systems, replacing cables for transmission of biomedical sensor data, have been designed and evaluated. The three sensor architectures are built on 1-, 2- and 3-chip solutions and depending on the monitoring situation and signal character, different solutions are optimal. Essential parameters for all systems have been low physical weight and small size, resistance to interference and interoperability with other technologies as global- or local networks, PC's and mobile phones. Two different biomedical input signals, ECG and PPG (photoplethysmography), have been used to evaluate the three solutions. The study shows that it is possibly to continuously transmit an analogue signal. At low sampling rates and slowly varying parameters, as monitoring the heart rate with PPG, the 1-chip solution is the most suitable, offering low power consumption and thus a longer battery lifetime or a smaller battery, minimizing the weight of the sensor system. On the other hand, when a higher sampling rate is required, as an ECG, the 3-chip architecture, with a FPGA or micro-controller, offers the best solution and performance. Our conclusion is that Bluetooth might be useful in replacing cables of medical monitoring systems.
Long-range non-contact imaging photoplethysmography: cardiac pulse wave sensing at a distance
NASA Astrophysics Data System (ADS)
Blackford, Ethan B.; Estepp, Justin R.; Piasecki, Alyssa M.; Bowers, Margaret A.; Klosterman, Samantha L.
2016-03-01
Non-contact, imaging photoplethysmography uses photo-optical sensors to measure variations in light absorption, caused by blood volume pulsations, to assess cardiopulmonary parameters including pulse rate, pulse rate variability, and respiration rate. Recently, researchers have studied the applications and methodology of imaging photoplethysmography. Basic research has examined some of the variables affecting data quality and accuracy of imaging photoplethysmography including signal processing, imager parameters (e.g. frame rate and resolution), lighting conditions, subject motion, and subject skin tone. This technology may be beneficial for long term or continuous monitoring where contact measurements may be harmful (e.g. skin sensitivities) or where imperceptible or unobtrusive measurements are desirable. Using previously validated signal processing methods, we examined the effects of imager-to-subject distance on one-minute, windowed estimates of pulse rate. High-resolution video of 22, stationary participants was collected using an enthusiast-grade, mirrorless, digital camera equipped with a fully-manual, super-telephoto lens at distances of 25, 50, and 100 meters with simultaneous contact measurements of electrocardiography, and fingertip photoplethysmography. By comparison, previous studies have usually been conducted with imager-to-subject distances of up to only a few meters. Mean absolute error for one-minute, windowed, pulse rate estimates (compared to those derived from gold-standard electrocardiography) were 2.0, 4.1, and 10.9 beats per minute at distances of 25, 50, and 100 meters, respectively. Long-range imaging presents several unique challenges among which include decreased, observed light reflectance and smaller regions of interest. Nevertheless, these results demonstrate that accurate pulse rate measurements can be obtained from over long imager-to-participant distances given these constraints.
Hong, Kyung Soon; Park, Kyu Tae; Ahn, Jae Mok
2015-01-01
Recent studies have emphasized the potential information embedded in peripheral fingertip photoplethysmogram (PPG) signals for the assessment of arterial wall stiffening during aging. For the discrimination of arterial stiffness with age, the brachial-ankle pulse wave velocity (baPWV) has been widely used in clinical applications. The second derivative of the PPG (acceleration photoplethysmogram [APG]) has been reported to correlate with the presence of atherosclerotic disorders. In this study, we investigated the association among age, the baPWV, and the APG and found a new aging index reflecting arterial stiffness for a healthcare device. The APG and the baPWV were simultaneously applied to assess the accuracy of the APG in measuring arterial stiffness in association with age. A preamplifier and motion artifact removal algorithm were newly developed to obtain a high quality PPG signal. In total, 168 subjects with a mean ± SD age of 58.1 ± 12.6 years were followed for two months to obtain a set of complete data using baPWV and APG analysis. The baPWV and the B ratio of the APG indices were correlated significantly with age (r = 0.6685, p < 0.0001 and r = -0.4025, p < 0.0001, respectively). A regression analysis revealed that the c and d peaks were independent of age (r = -0.3553, p < 0.0001 and r = -0.3191, p < 0.0001, respectively). We determined the B ratio, which represents an improved aging index and suggest that the APG may provide qualitatively similar information for arterial stiffness.
Influence of skin type and wavelength on light wave reflectance.
Fallow, Bennett A; Tarumi, Takashi; Tanaka, Hirofumi
2013-06-01
A new application of photoplethysmography (PPG) has emerged recently to provide the possibility of heart rate monitoring without a telemetric chest strap. The aim of this study was to determine if a new device could detect pulsation over a broad range of skin types, and what light wavelength would be most suitable for detecting the signals. A light emitting diode-based PPG system was used to detect changes in pulsatile blood flow on 23 apparently healthy individuals (11 male and 12 female, 20-59 years old) of varying skin types classified according to a questionnaire in combination with digital photographs with a skin type chart. Four different light wavelengths (470, 520, 630, and 880 nm) were tested. Normalized modulation level is calculated as the AC/DC component ratio and represents the change in flow over the underlying constant state of flow or perfusion. In the resting condition, green light wavelength (520 nm) displayed greater modulation (p < 0.001) than all the other wavelengths analyzed regardless of skin types. Type V (dark brown) skin type was significantly lower in modulation than all other skin types. In the exercise condition, both blue (470 nm) and green (520 nm) light wavelengths displayed greater signal-to-noise ratios than red (630 nm) or infrared (880 nm) light wavelengths (p < 0.001). We concluded that a PPG-based device can detect pulsation across all skin types and that a greater resolution was obtained using a green light wavelength at rest and a green or blue light wavelength during exercise.
Hong, Kyung Soon; Park, Kyu Tae
2015-01-01
Objectives Recent studies have emphasized the potential information embedded in peripheral fingertip photoplethysmogram (PPG) signals for the assessment of arterial wall stiffening during aging. For the discrimination of arterial stiffness with age, the brachial-ankle pulse wave velocity (baPWV) has been widely used in clinical applications. The second derivative of the PPG (acceleration photoplethysmogram [APG]) has been reported to correlate with the presence of atherosclerotic disorders. In this study, we investigated the association among age, the baPWV, and the APG and found a new aging index reflecting arterial stiffness for a healthcare device. Methods The APG and the baPWV were simultaneously applied to assess the accuracy of the APG in measuring arterial stiffness in association with age. A preamplifier and motion artifact removal algorithm were newly developed to obtain a high quality PPG signal. In total, 168 subjects with a mean ± SD age of 58.1 ± 12.6 years were followed for two months to obtain a set of complete data using baPWV and APG analysis. Results The baPWV and the B ratio of the APG indices were correlated significantly with age (r = 0.6685, p < 0.0001 and r = -0.4025, p < 0.0001, respectively). A regression analysis revealed that the c and d peaks were independent of age (r = -0.3553, p < 0.0001 and r = -0.3191, p < 0.0001, respectively). Conclusions We determined the B ratio, which represents an improved aging index and suggest that the APG may provide qualitatively similar information for arterial stiffness. PMID:25705555
Beat-to-Beat Blood Pressure Monitor
NASA Technical Reports Server (NTRS)
Lee, Yong Jin
2012-01-01
This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes. Photoplethysmography, which measures changes in arterial blood volume, is commonly used to obtain heart rate and blood oxygen saturation. The digitized PPG signals are used as inputs into the beat-to-beat blood pressure measurement algorithm.
NASA Astrophysics Data System (ADS)
Blazek, Vladimir; Schmitt, Hans J.; Rao, M. Mukunda
1999-04-01
In recent years investigation and understanding of the interaction between brain activity and human hemodynamics is receiving much attention. Such investigations are generally confined to few select premier research institutions where expensive and sophisticated facilities like PET, NMRI, etc. are available. Actual advancement in optoelectronics and computer technology have accelerated the development of new measuring systems and methodologies for use in this medical field. Specifically, transcutaneous assessment of skin perfusion changes (blood volumetric measurement) through optical sensor based Photoplethysmography (PPG) has rapidly gained an important role. This basically noninvasive measuring procedure is devoid of harmful radiation and ionizing phenomena, simple in construction and connection to the measuring setup and is easy to use in all areas of human body. The relatively low cost of these sensors have resulted in their use in varied medical fields for extensive clinical applications. In the past, the application of PPG had been limited by technical difficulties involving calibration of the data. The development of quantitative PPG technique based on computer-aided data processing has removed this obstacle. In co-operation between Indian Institute of Technology at Chennai and Aachen University of Technology an Indo-German Project was initiated in 1996 for advanced studies in this research area. Measuring system design, experimental details and some preliminary results obtained so far within the framework of this project are presented in this paper. From the investigations carried out so far using the PPG sensors in conjunction with breathing sensors, it has been possible to monitor the 0.125 to 0.15 Hz rhythms in the arterial volumetric changes and to study the influence of breathing on them. These rhythms, which according to medical experts have relevance to psychosomatic conditions e.g. stress or relaxation, can also be addressed to by ancient Indian practices like yoga and meditation.
Multiple diagnosis based on photoplethysmography: hematocrit, SpO2, pulse, and respiration
NASA Astrophysics Data System (ADS)
Yoon, Gilwon; Lee, Jong Y.; Jeon, Kye Jin; Park, Kun-Kook; Yeo, Hyung S.; Hwang, Hyun T.; Kim, Hong S.; Hwang, In-Duk
2002-09-01
Photo-plethysmography measures pulsatile blood flow in real-time and non-invasively. One of widely known applications of PPG is the measurement of saturated oxygen in arterial blood(SpO2). In our work, using several wavelengths more than those used in a pulse oximeter, an algorithm and instrument have been developed to measure hematocrit, saturated oxygen, pulse and respiratory rates simultaneously. To predict hematocrit, a dedicated algorithm is developed based on scattering of RBC and a protocol for detecting outlier signals is used to increase accuracy and reliability. Digital filtering techniques are used to extract respiratory rate signals. Utilization of wavelengths under 1000nm and a multi-wavelength LED array chip and digital-oriented electronics enable us to make a compact device. Our preliminary clinical trials show that the achieved percent errors are +/-8.2% for hematocrit when tested with 594 persons, R2 for SpO2 fitting is 0.99985 when tested with a Bi-Tek pulse oximeter simulator and the SpO2 error for in vivo test is +/-2.5% over the range of 75~100%. The error of pulse rates is less than +/-5%. We obtained a positive predictive value of 96% for respiratory rates in qualitative analysis.
Adaptive motion artifact reducing algorithm for wrist photoplethysmography application
NASA Astrophysics Data System (ADS)
Zhao, Jingwei; Wang, Guijin; Shi, Chenbo
2016-04-01
Photoplethysmography (PPG) technology is widely used in wearable heart pulse rate monitoring. It might reveal the potential risks of heart condition and cardiopulmonary function by detecting the cardiac rhythms in physical exercise. However the quality of wrist photoelectric signal is very sensitive to motion artifact since the thicker tissues and the fewer amount of capillaries. Therefore, motion artifact is the major factor that impede the heart rate measurement in the high intensity exercising. One accelerometer and three channels of light with different wavelengths are used in this research to analyze the coupled form of motion artifact. A novel approach is proposed to separate the pulse signal from motion artifact by exploiting their mixing ratio in different optical paths. There are four major steps of our method: preprocessing, motion artifact estimation, adaptive filtering and heart rate calculation. Five healthy young men are participated in the experiment. The speeder in the treadmill is configured as 12km/h, and all subjects would run for 3-10 minutes by swinging the arms naturally. The final result is compared with chest strap. The average of mean square error (MSE) is less than 3 beats per minute (BPM/min). Proposed method performed well in intense physical exercise and shows the great robustness to individuals with different running style and posture.
Using consumer-grade devices for multi-imager non-contact imaging photoplethysmography
NASA Astrophysics Data System (ADS)
Blackford, Ethan B.; Estepp, Justin R.
2017-02-01
Imaging photoplethysmography is a technique through which the morphology of the blood volume pulse can be obtained through non-contact video recordings of exposed skin with superficial vasculature. The acceptance of such a convenient modality for use in everyday applications may well depend upon the availability of consumer-grade imagers that facilitate ease-of-adoption. Multiple imagers have been used previously in concept demonstrations, showing improvements in quality of the extracted blood volume pulse signal. However, the use of multi-imager sensors requires synchronization of the frame exposures between the individual imagers, a capability that has only recently been available without creating custom solutions. In this work, we consider the use of multiple, commercially-available, synchronous imagers for use in imaging photoplethysmography. A commercially-available solution for adopting multi-imager synchronization was analyzed for 21 stationary, seated participants while ground-truth physiological signals were simultaneously measured. A total of three imagers were used, facilitating a comparison between fused data from all three imagers versus data from the single, central imager in the array. The within-subjects design included analyses of pulse rate and pulse signal-to-noise ratio. Using the fused data from the triple-imager array, mean absolute error in pulse rate measurement was reduced to 3.8 as compared to 7.4 beats per minute with the single imager. While this represents an overall improvement in the multi-imager case, it is also noted that these errors are substantially higher than those obtained in comparable studies. We further discuss these results and their implications for using readily-available commercial imaging solutions for imaging photoplethysmography applications.
Dual-modality arterial pulse monitoring system for continuous blood pressure measurement.
Wen-Xuan Dai; Yuan-Ting Zhang; Jing Liu; Xiao-Rong Ding; Ni Zhao
2016-08-01
Accurate and ambulatory measurement of blood pressure (BP) is essential for efficient diagnosis, management and prevention of cardiovascular diseases (CVDs). However, traditional cuff-based BP measurement methods provide only intermittent BP readings and can cause discomfort with the occlusive cuff. Although pulse transit time (PTT) method is promising for cuffless and continuous BP measurement, its pervasive use is restricted by its limited accuracy and requirement of placing sensors on multiple body sites. To tackle these issues, we propose a novel dual-modality arterial pulse monitoring system for continuous blood pressure measurement, which simultaneously records the pressure and photoplethysmography (PPG) signals of radial artery. The obtained signals can be used to generate a pressure-volume curve, from which the elasticity index (EI) and viscosity index (VI) can be extracted. Experiments were carried out among 7 healthy subjects with their PPG, ECG, arterial pressure wave and reference BP collected to examine the effectiveness of the proposed indexes. The results of this study demonstrate that a linear regression model combining EI and VI has significantly higher BP tracking correlation coefficient as compared to the PTT method. This suggests that the proposed system and method can potentially be used for convenient and continuous blood pressure estimation with higher accuracy.
Optical sensor technology for a noninvasive continuous monitoring of blood components
NASA Astrophysics Data System (ADS)
Kraitl, Jens; Timm, Ulrich; Lewis, Elfed; Ewald, Hartmut
2010-02-01
NIR-spectroscopy and Photoplethysmography (PPG) is used for a measurement of blood components. The absorptioncoefficient of blood differs at different wavelengths. This fact is used to calculate the optical absorbability characteristics of blood which is yielding information about blood components like hemoglobin (Hb), carboxyhemoglobin (CoHb) and arterial oxygen saturation (SpO2). The measured PPG time signals and the ratio between the peak to peak pulse amplitudes are used for a measurement of these parameters. Hemoglobin is the main component of red blood cells. The primary function of Hb is the transport of oxygen from the lungs to the tissue and carbon dioxide back to the lungs. The Hb concentration in human blood is an important parameter in evaluating the physiological status of an individual and an essential parameter in every blood count. Currently, invasive methods are used to measure the Hb concentration, whereby blood is taken from the patient and subsequently analyzed. Apart from the discomfort of drawing blood samples, an added disadvantage of this method is the delay between the blood collection and its analysis, which does not allow real time patient monitoring in critical situations. A noninvasive method allows pain free continuous on-line patient monitoring with minimum risk of infection and facilitates real time data monitoring allowing immediate clinical reaction to the measured data.
A visible light imaging device for cardiac rate detection with reduced effect of body movement
NASA Astrophysics Data System (ADS)
Jiang, Xiaotian; Liu, Ming; Zhao, Yuejin
2014-09-01
A visible light imaging system to detect human cardiac rate is proposed in this paper. A color camera and several LEDs, acting as lighting source, were used to avoid the interference of ambient light. From people's forehead, the cardiac rate could be acquired based on photoplethysmography (PPG) theory. The template matching method was used after the capture of video. The video signal was discomposed into three signal channels (RGB) and the region of interest was chosen to take the average gray value. The green channel signal could provide an excellent waveform of pulse wave on the account of green lights' absorptive characteristics of blood. Through the fast Fourier transform, the cardiac rate was exactly achieved. But the research goal was not just to achieve the cardiac rate accurately. With the template matching method, the effects of body movement are reduced to a large extent, therefore the pulse wave can be detected even while people are in the moving state and the waveform is largely optimized. Several experiments are conducted on volunteers, and the results are compared with the ones gained by a finger clamped pulse oximeter. The contrast results between these two ways are exactly agreeable. This method to detect the cardiac rate and the pulse wave largely reduces the effects of body movement and can probably be widely used in the future.
Yuan, Hongwei; Poeggel, Sven; Newe, Thomas; Lewis, Elfed; Viphavakit, Charusluk; Leen, Gabriel
2017-03-10
A comprehensive study of the effect of a wide range of controlled human subject motion on Photoplethysmographic signals is reported. The investigation includes testing of two separate groups of 5 and 18 subjects who were asked to undertake set exercises whilst simultaneously monitoring a wide range of physiological parameters including Breathing Rate, Heart Rate and Localised Blood Pressure using commercial clinical sensing systems. The unique finger mounted PPG probe equipped with miniature three axis accelerometers for undertaking this investigation was a purpose built in-house version which is designed to facilitate reproducible application to a wide range of human subjects and the study of motion. The subjects were required to undertake several motion based exercises including standing, sitting and lying down and transitions between these states. They were also required to undertake set arm movements including arm-swinging and wrist rotation. A comprehensive set of experimental results corresponding to all motion inducing exercises have been recorded and analysed including the baseline (BL) value (DC component) and the amplitude of the oscillation of the PPG. All physiological parameters were also recorded as a simultaneous time varying waveform. The effects of the motion and specifically the localised Blood Pressure (BP) have been studied and related to possible influences of the Autonomic Nervous System (ANS) and hemodynamic pressure variations. It is envisaged that a comprehensive study of the effect of motion and the localised pressure fluctuations will provide valuable information for the future minimisation of motion artefact effect on the PPG signals of this probe and allow the accurate assessment of total haemoglobin concentration which is the primary function of the probe.
Calibration of Contactless Pulse Oximetry
Bartula, Marek; Bresch, Erik; Rocque, Mukul; Meftah, Mohammed; Kirenko, Ihor
2017-01-01
BACKGROUND: Contactless, camera-based photoplethysmography (PPG) interrogates shallower skin layers than conventional contact probes, either transmissive or reflective. This raises questions on the calibratability of camera-based pulse oximetry. METHODS: We made video recordings of the foreheads of 41 healthy adults at 660 and 840 nm, and remote PPG signals were extracted. Subjects were in normoxic, hypoxic, and low temperature conditions. Ratio-of-ratios were compared to reference Spo2 from 4 contact probes. RESULTS: A calibration curve based on artifact-free data was determined for a population of 26 individuals. For an Spo2 range of approximately 83% to 100% and discarding short-term errors, a root mean square error of 1.15% was found with an upper 99% one-sided confidence limit of 1.65%. Under normoxic conditions, a decrease in ambient temperature from 23 to 7°C resulted in a calibration error of 0.1% (±1.3%, 99% confidence interval) based on measurements for 3 subjects. PPG signal strengths varied strongly among individuals from about 0.9 × 10−3 to 4.6 × 10−3 for the infrared wavelength. CONCLUSIONS: For healthy adults, the results present strong evidence that camera-based contactless pulse oximetry is fundamentally feasible because long-term (eg, 10 minutes) error stemming from variation among individuals expressed as A*rms is significantly lower (<1.65%) than that required by the International Organization for Standardization standard (<4%) with the notion that short-term errors should be added. A first illustration of such errors has been provided with A**rms = 2.54% for 40 individuals, including 6 with dark skin. Low signal strength and subject motion present critical challenges that will have to be addressed to make camera-based pulse oximetry practically feasible. PMID:27258081
NASA Astrophysics Data System (ADS)
Sun, Di; Guo, Chao; Zhang, Ziyang; Han, Tongshuai; Liu, Jin
2016-10-01
The blood hemoglobin concentration's (BHC) measurement using Photoplethysmography (PPG), which gets blood absorption to near infrared light from the instantaneous pulse of transmitted light intensity, has not been applied to the clinical use due to the non-enough precision. The main challenge might be caused of the non-enough stable pulse signal when it's very weak and it often varies in different human bodies or in the same body with different physiological states. We evaluated the detection limit of BHC using PPG as the measurement precision level, which can be considered as a best precision result because we got the relative stable subject's pulse signals recorded by using a spectrometer with high signal-to-noise ratio (SNR) level, which is about 30000:1 in short term. Moreover, we optimized the used pathlength using the theory based on optimum pathlength to get a better sensitivity to the absorption variation in blood. The best detection limit was evaluated as about 1 g/L for BHC, and the best SNR of pulse for in vivo measurement was about 2000:1 at 1130 and 1250 nm. Meanwhile, we conclude that the SNR of pulse signal should be better than 400:1 when the required detection limit is set to 5 g/L. Our result would be a good reference to the BHC measurement to get a desired BHC measurement precision of real application.
A PC-aided optical foetal heart rate detection system.
Oweis, Rami J; As'ad, Hala; Aldarawsheh, Amany; Al-Khdeirat, Rawan; Lwissy, Kaldoun
2014-01-01
Safe monitoring of foetal heart rate is a valuable tool for the healthy evolution and wellbeing of both foetus and mother. This paper presents a non-invasive optical technique that allows for foetal heart rate detection using a photovoltaic infrared (IR) detector placed on the mother's abdomen. The system presented here consists of a photoplethysmography (PPG) circuit, abdomen circuit and a personal computer equipped with MATLAB. A near IR beam having a wavelength of 880 nm is transmitted through the mother's abdomen and foetal tissue. The received abdominal signal that conveys information pertaining to the mother and foetal heart rate is sensed by a low noise photodetector. The PC receives the signal through the National Instrumentation Data Acquisition Card (NIDAQ). After synchronous detection of the abdominal and finger PPG signals, the designed MATLAB-based software saves, analyses and extracts information related to the foetal heart rate. Extraction is carried out using recursive least squares adaptive filtration. Measurements on eight pregnant women with gestational periods ranging from 35-39 weeks were performed using the proposed system and CTG. Results show a correlation coefficient of 0.978 and a correlation confidence interval between 88-99.6%. The t test results in a p value of 0.034, which is less than 0.05. Low power, low cost, high signal-to-noise ratio, reduction of ambient light effect and ease of use are the main characteristics of the proposed system.
Using Psychophysiological Sensors to Assess Mental Workload During Web Browsing.
Jimenez-Molina, Angel; Retamal, Cristian; Lira, Hernan
2018-02-03
Knowledge of the mental workload induced by a Web page is essential for improving users' browsing experience. However, continuously assessing the mental workload during a browsing task is challenging. To address this issue, this paper leverages the correlation between stimuli and physiological responses, which are measured with high-frequency, non-invasive psychophysiological sensors during very short span windows. An experiment was conducted to identify levels of mental workload through the analysis of pupil dilation measured by an eye-tracking sensor. In addition, a method was developed to classify mental workload by appropriately combining different signals (electrodermal activity (EDA), electrocardiogram, photoplethysmo-graphy (PPG), electroencephalogram (EEG), temperature and pupil dilation) obtained with non-invasive psychophysiological sensors. The results show that the Web browsing task involves four levels of mental workload. Also, by combining all the sensors, the efficiency of the classification reaches 93.7%.
Flexible wearable sensor nodes with solar energy harvesting.
Taiyang Wu; Arefin, Md Shamsul; Redoute, Jean-Michel; Yuce, Mehmet Rasit
2017-07-01
Wearable sensor nodes have gained a lot of attention during the past few years as they can monitor and record people's physical parameters in real time. Wearable sensor nodes can promote healthy lifestyles and prevent the occurrence of potential illness or injuries. This paper presents a flexible wearable sensor system powered by an efficient solar energy harvesting technique. It can measure the subject's heartbeats using a photoplethysmography (PPG) sensor and perform activity monitoring using an accelerometer. The solar energy harvester adopts an output current based maximum power point tracking (MPPT) algorithm, which controls the solar panel to operate within its high output power range. The power consumption of the flexible sensor nodes has been investigated under different operation conditions. Experimental results demonstrate that wearable sensor nodes can work for more than 12 hours when they are powered by the solar energy harvester for 3 hours in the bright sunlight.
Using Psychophysiological Sensors to Assess Mental Workload During Web Browsing
Jimenez-Molina, Angel; Retamal, Cristian; Lira, Hernan
2018-01-01
Knowledge of the mental workload induced by a Web page is essential for improving users’ browsing experience. However, continuously assessing the mental workload during a browsing task is challenging. To address this issue, this paper leverages the correlation between stimuli and physiological responses, which are measured with high-frequency, non-invasive psychophysiological sensors during very short span windows. An experiment was conducted to identify levels of mental workload through the analysis of pupil dilation measured by an eye-tracking sensor. In addition, a method was developed to classify mental workload by appropriately combining different signals (electrodermal activity (EDA), electrocardiogram, photoplethysmo-graphy (PPG), electroencephalogram (EEG), temperature and pupil dilation) obtained with non-invasive psychophysiological sensors. The results show that the Web browsing task involves four levels of mental workload. Also, by combining all the sensors, the efficiency of the classification reaches 93.7%. PMID:29401688
NASA Astrophysics Data System (ADS)
Martin, Stephanie L.-O.; Carek, Andrew M.; Kim, Chang-Sei; Ashouri, Hazar; Inan, Omer T.; Hahn, Jin-Oh; Mukkamala, Ramakrishna
2016-12-01
Pulse transit time (PTT) is being widely pursued for cuff-less blood pressure (BP) monitoring. Most efforts have employed the time delay between ECG and finger photoplethysmography (PPG) waveforms as a convenient surrogate of PTT. However, these conventional pulse arrival time (PAT) measurements include the pre-ejection period (PEP) and the time delay through small, muscular arteries and may thus be an unreliable marker of BP. We assessed a bathroom weighing scale-like system for convenient measurement of ballistocardiography and foot PPG waveforms - and thus PTT through larger, more elastic arteries - in terms of its ability to improve tracking of BP in individual subjects. We measured “scale PTT”, conventional PAT, and cuff BP in humans during interventions that increased BP but changed PEP and smooth muscle contraction differently. Scale PTT tracked the diastolic BP changes well, with correlation coefficient of -0.80 ± 0.02 (mean ± SE) and root-mean-squared-error of 7.6 ± 0.5 mmHg after a best-case calibration. Conventional PAT was significantly inferior in tracking these changes, with correlation coefficient of -0.60 ± 0.04 and root-mean-squared-error of 14.6 ± 1.5 mmHg (p < 0.05). Scale PTT also tracked the systolic BP changes better than conventional PAT but not to an acceptable level. With further development, scale PTT may permit reliable, convenient measurement of BP.
Can Wearable Devices Accurately Measure Heart Rate Variability? A Systematic Review.
Georgiou, Konstantinos; Larentzakis, Andreas V; Khamis, Nehal N; Alsuhaibani, Ghadah I; Alaska, Yasser A; Giallafos, Elias J
2018-03-01
A growing number of wearable devices claim to provide accurate, cheap and easily applicable heart rate variability (HRV) indices. This is mainly accomplished by using wearable photoplethysmography (PPG) and/or electrocardiography (ECG), through simple and non-invasive techniques, as a substitute of the gold standard RR interval estimation through electrocardiogram. Although the agreement between pulse rate variability (PRV) and HRV has been evaluated in the literature, the reported results are still inconclusive especially when using wearable devices. The purpose of this systematic review is to investigate if wearable devices provide a reliable and precise measurement of classic HRV parameters in rest as well as during exercise. A search strategy was implemented to retrieve relevant articles from MEDLINE and SCOPUS databases, as well as, through internet search. The 308 articles retrieved were reviewed for further evaluation according to the predetermined inclusion/exclusion criteria. Eighteen studies were included. Sixteen of them integrated ECG - HRV technology and two of them PPG - PRV technology. All of them examined wearable devices accuracy in RV detection during rest, while only eight of them during exercise. The correlation between classic ECG derived HRV and the wearable RV ranged from very good to excellent during rest, yet it declined progressively as exercise level increased. Wearable devices may provide a promising alternative solution for measuring RV. However, more robust studies in non-stationary conditions are needed using appropriate methodology in terms of number of subjects involved, acquisition and analysis techniques implied.
Martin, Stephanie L-O; Carek, Andrew M; Kim, Chang-Sei; Ashouri, Hazar; Inan, Omer T; Hahn, Jin-Oh; Mukkamala, Ramakrishna
2016-12-15
Pulse transit time (PTT) is being widely pursued for cuff-less blood pressure (BP) monitoring. Most efforts have employed the time delay between ECG and finger photoplethysmography (PPG) waveforms as a convenient surrogate of PTT. However, these conventional pulse arrival time (PAT) measurements include the pre-ejection period (PEP) and the time delay through small, muscular arteries and may thus be an unreliable marker of BP. We assessed a bathroom weighing scale-like system for convenient measurement of ballistocardiography and foot PPG waveforms - and thus PTT through larger, more elastic arteries - in terms of its ability to improve tracking of BP in individual subjects. We measured "scale PTT", conventional PAT, and cuff BP in humans during interventions that increased BP but changed PEP and smooth muscle contraction differently. Scale PTT tracked the diastolic BP changes well, with correlation coefficient of -0.80 ± 0.02 (mean ± SE) and root-mean-squared-error of 7.6 ± 0.5 mmHg after a best-case calibration. Conventional PAT was significantly inferior in tracking these changes, with correlation coefficient of -0.60 ± 0.04 and root-mean-squared-error of 14.6 ± 1.5 mmHg (p < 0.05). Scale PTT also tracked the systolic BP changes better than conventional PAT but not to an acceptable level. With further development, scale PTT may permit reliable, convenient measurement of BP.
Pollonini, L; Padhye, N S; Re, R; Torricelli, A; Simpson, R J; Dacso, C C
2015-05-01
Heart rate (HR) is a valuable and widespread measure for physical training programs, although its description of conditioning is limited to the cardiac response to exercise. More comprehensive measures of exercise adaptation include cardiac output (Q̇), stroke volume (SV) and oxygen uptake (V̇O2), but these physiological parameters can be measured only with cumbersome equipment installed in clinical settings. In this work, we explore the ability of pulse transit time (PTT) to represent a valuable pairing with HR for indirectly estimating Q̇, SV and V̇O2 non-invasively. PTT was measured as the time interval between the peak of the electrocardiographic (ECG) R-wave and the onset of the photoplethysmography (PPG) waveform at the periphery (i.e. fingertip) with a portable sensor. Fifteen healthy young subjects underwent a graded incremental cycling protocol after which HR and PTT were correlated with Q̇, SV and V̇O2 using linear mixed models. The addition of PTT significantly improved the modeling of Q̇, SV and V̇O2 at the individual level ([Formula: see text] for SV, 0.548 for Q̇, and 0.771 for V̇O2) compared to predictive models based solely on HR ([Formula: see text] for SV, 0.503 for Q̇, and 0.745 for V̇O2). While challenges in sensitivity and artifact rejection exist, combining PTT with HR holds potential for development of novel wearable sensors that provide exercise assessment largely superior to HR monitors.
Robust tracking of respiratory rate in high-dynamic range scenes using mobile thermal imaging
Cho, Youngjun; Julier, Simon J.; Marquardt, Nicolai; Bianchi-Berthouze, Nadia
2017-01-01
The ability to monitor the respiratory rate, one of the vital signs, is extremely important for the medical treatment, healthcare and fitness sectors. In many situations, mobile methods, which allow users to undertake everyday activities, are required. However, current monitoring systems can be obtrusive, requiring users to wear respiration belts or nasal probes. Alternatively, contactless digital image sensor based remote-photoplethysmography (PPG) can be used. However, remote PPG requires an ambient source of light, and does not work properly in dark places or under varying lighting conditions. Recent advances in thermographic systems have shrunk their size, weight and cost, to the point where it is possible to create smart-phone based respiration rate monitoring devices that are not affected by lighting conditions. However, mobile thermal imaging is challenged in scenes with high thermal dynamic ranges (e.g. due to the different environmental temperature distributions indoors and outdoors). This challenge is further amplified by general problems such as motion artifacts and low spatial resolution, leading to unreliable breathing signals. In this paper, we propose a novel and robust approach for respiration tracking which compensates for the negative effects of variations in the ambient temperature and motion artifacts and can accurately extract breathing rates in highly dynamic thermal scenes. The approach is based on tracking the nostril of the user and using local temperature variations to infer inhalation and exhalation cycles. It has three main contributions. The first is a novel Optimal Quantization technique which adaptively constructs a color mapping of absolute temperature to improve segmentation, classification and tracking. The second is the Thermal Gradient Flow method that computes thermal gradient magnitude maps to enhance the accuracy of the nostril region tracking. Finally, we introduce the Thermal Voxel method to increase the reliability of the captured respiration signals compared to the traditional averaging method. We demonstrate the extreme robustness of our system to track the nostril-region and measure the respiratory rate by evaluating it during controlled respiration exercises in high thermal dynamic scenes (e.g. strong correlation (r = 0.9987) with the ground truth from the respiration-belt sensor). We also demonstrate how our algorithm outperformed standard algorithms in settings with different amounts of environmental thermal changes and human motion. We open the tracked ROI sequences of the datasets collected for these studies (i.e. under both controlled and unconstrained real-world settings) to the community to foster work in this area. PMID:29082079
Robust tracking of respiratory rate in high-dynamic range scenes using mobile thermal imaging.
Cho, Youngjun; Julier, Simon J; Marquardt, Nicolai; Bianchi-Berthouze, Nadia
2017-10-01
The ability to monitor the respiratory rate, one of the vital signs, is extremely important for the medical treatment, healthcare and fitness sectors. In many situations, mobile methods, which allow users to undertake everyday activities, are required. However, current monitoring systems can be obtrusive, requiring users to wear respiration belts or nasal probes. Alternatively, contactless digital image sensor based remote-photoplethysmography (PPG) can be used. However, remote PPG requires an ambient source of light, and does not work properly in dark places or under varying lighting conditions. Recent advances in thermographic systems have shrunk their size, weight and cost, to the point where it is possible to create smart-phone based respiration rate monitoring devices that are not affected by lighting conditions. However, mobile thermal imaging is challenged in scenes with high thermal dynamic ranges (e.g. due to the different environmental temperature distributions indoors and outdoors). This challenge is further amplified by general problems such as motion artifacts and low spatial resolution, leading to unreliable breathing signals. In this paper, we propose a novel and robust approach for respiration tracking which compensates for the negative effects of variations in the ambient temperature and motion artifacts and can accurately extract breathing rates in highly dynamic thermal scenes. The approach is based on tracking the nostril of the user and using local temperature variations to infer inhalation and exhalation cycles. It has three main contributions. The first is a novel Optimal Quantization technique which adaptively constructs a color mapping of absolute temperature to improve segmentation, classification and tracking. The second is the Thermal Gradient Flow method that computes thermal gradient magnitude maps to enhance the accuracy of the nostril region tracking. Finally, we introduce the Thermal Voxel method to increase the reliability of the captured respiration signals compared to the traditional averaging method. We demonstrate the extreme robustness of our system to track the nostril-region and measure the respiratory rate by evaluating it during controlled respiration exercises in high thermal dynamic scenes (e.g. strong correlation (r = 0.9987) with the ground truth from the respiration-belt sensor). We also demonstrate how our algorithm outperformed standard algorithms in settings with different amounts of environmental thermal changes and human motion. We open the tracked ROI sequences of the datasets collected for these studies (i.e. under both controlled and unconstrained real-world settings) to the community to foster work in this area.
cHRV Uncovering Daily Stress Dynamics Using Bio-Signal from Consumer Wearables.
Hao, Tian; Chang, Henry; Ball, Marion; Lin, Kun; Zhu, Xinxin
2017-01-01
Knowing the dynamics of one's daily stress is essential to effective stress management in the context of smart and connected health. However, there lacks a practical and unobtrusive means to obtain real-time and longitudinal stress information. In this paper, we attempt to derive a convenient HRV-based (heart rate variability) biomarker named cHRV, which can be used to reliably reflect stress dynamics. cHRV's key advantage lies in its low maintenance and high practicality. It can be efficiently calculated only using data from photoplethysmography (PPG) sensors, the mainstream heart rate sensor embedded in most of the consumer wearables like Apple Watch. Benefiting from the proliferation of wearables, cHRV is ideal for day-to-day stress monitoring. To evaluate its feasibility and performance, we have conducted 14 in-lab controlled experiments. The result shows that the proposed cHRV has strong correlation with the stress dynamics (r > 0.95), therefore exhibits great potential for continuous stress assessment.
Optical sensor technology for a noninvasive medical blood diagnosis
NASA Astrophysics Data System (ADS)
Kraitl, Jens; Ewald, Hartmut; Gehring, Hartmut
2007-02-01
NIR-spectroscopy and Photoplethysmography (PPG) and is used for a measurement of blood components. The fact that the absorption-coefficients μ a and scattering-coefficients μ s for blood differ at difference wavelengths has been exploited and is used for calculation of the optical absorbability characteristics of human blood yielding information on blood components like hemoglobin and oxygen saturation. The measured PPG time signals and the ratio between the peak to peak pulse amplitudes are used for a measurement of these parameters. A newly developed PMD device has been introduced. The non-invasive in-vivo multi-spectral method is based on the radiation of monochromatic light, emitted by laser diodes, through an area of skin on the finger. Deferrals between the proportions of hemoglobin and plasma in the intravasal volume should be detected photo-electrically by signal-analytic evaluation of the signals. The computed nonlinear coefficients are used for the measurement and calculation of the relative hemoglobin concentration change. Results with this photometric method to measure changes in the hemoglobin concentration were demonstrated during measurements with a hemodynamic model and healthy subjects. The PMD is suitable for non-invasive continuous online monitoring of one or more biologic constituent values. The objective of this development is to reduce the dependence on measurement techniques which require that a sample of blood be withdrawn from the patient for in-vitro analysis. Any invasive method used on the patient to obtain blood is accompanied by problems of inconvenience, stress, and discomfort. The patient is also exposed to the normal risks of infection associated with such invasive methods.
Martin, Stephanie L.-O.; Carek, Andrew M.; Kim, Chang-Sei; Ashouri, Hazar; Inan, Omer T.; Hahn, Jin-Oh; Mukkamala, Ramakrishna
2016-01-01
Pulse transit time (PTT) is being widely pursued for cuff-less blood pressure (BP) monitoring. Most efforts have employed the time delay between ECG and finger photoplethysmography (PPG) waveforms as a convenient surrogate of PTT. However, these conventional pulse arrival time (PAT) measurements include the pre-ejection period (PEP) and the time delay through small, muscular arteries and may thus be an unreliable marker of BP. We assessed a bathroom weighing scale-like system for convenient measurement of ballistocardiography and foot PPG waveforms – and thus PTT through larger, more elastic arteries – in terms of its ability to improve tracking of BP in individual subjects. We measured “scale PTT”, conventional PAT, and cuff BP in humans during interventions that increased BP but changed PEP and smooth muscle contraction differently. Scale PTT tracked the diastolic BP changes well, with correlation coefficient of −0.80 ± 0.02 (mean ± SE) and root-mean-squared-error of 7.6 ± 0.5 mmHg after a best-case calibration. Conventional PAT was significantly inferior in tracking these changes, with correlation coefficient of −0.60 ± 0.04 and root-mean-squared-error of 14.6 ± 1.5 mmHg (p < 0.05). Scale PTT also tracked the systolic BP changes better than conventional PAT but not to an acceptable level. With further development, scale PTT may permit reliable, convenient measurement of BP. PMID:27976741
Examining gender specificity of sexual response with concurrent thermography and plethysmography.
Huberman, Jackie S; Chivers, Meredith L
2015-10-01
Men's genital responses are significantly greater to sexual stimuli of their preferred gender compared to their nonpreferred gender (gender-specific), whereas androphilic (i.e., sexually attracted to men) women's genital responses are similar to sexual stimuli depicting either women or men (gender-nonspecific). This gendered pattern of genital response has only been demonstrated using vaginal photoplethysmography (VPP) in women and primarily penile plethysmography (PPG) in men. These measures assess different aspects of genital vasocongestion, thereby limiting comparisons between genders. Thermography is a newer sexual psychophysiology methodology that measures genital vasocongestion via temperature change and is better suited to assess sexual response between genders because the dependent measure, change in genital temperature, is similar for women and men. Further, previous studies have assessed gender specificity of sexual response across relatively short sexual stimuli, allowing only the examination of initial phases of sexual response. We examined gender specificity of sexual arousal by measuring women's and men's genital responses to lengthier stimuli with concurrent thermography and VPP/PPG. Gynephilic men (i.e., sexually attracted to women; n = 27) and androphilic women (n = 28) viewed 10-min films depicting men masturbating, women masturbating, and a nonsexual film, and reported feelings of sexual arousal while genital responses were assessed. Across measures, men's sexual responses were gender-specific and women's responses were gender-nonspecific, indicating that the gender difference in gender specificity of arousal is robust to methodology and stimulus duration. These findings replicate previous research, extend knowledge of gendered sexual response, and highlight the utility of multimethod approaches in sexual psychophysiology. © 2015 Society for Psychophysiological Research.
Heart Rate assessment by means of a novel approach applied to signals of different nature
NASA Astrophysics Data System (ADS)
Cosoli, G.; Casacanditella, L.; Tomasini, EP; Scalise, L.
2017-01-01
Electrocardiographic (ECG) signal presents many clinically relevant features (e.g. QT-interval, that is the duration of the ventricular depolarization). A novel processing technique has been demonstrated to be capable to measure some important characteristics according to the morphology of the waveform. Basing on that, the aim of this work is to propose an improved algorithm and to prove its efficacy in the assessment of the subject’s Heart Rate (HR) in comparison to standard algorithms (i.e. Pan & Tompkins). Results obtained in experimentally collected ECG signals for the identification of the main feature (R-peak) are comparable to those obtained with the traditional approach (sensitivity of 99.55% and 99.95%, respectively). Moreover, the use of this algorithm has been broaden to signals coming from different biomedical sensors (based on optical, acoustical and mechanical principles), all related to blood flow, for the computation of HR. In particular, it has been employed to PCG (Phonocardiography), PPG (Photoplethysmography) and VCG (Vibrocardiography), where standard algorithms could not be widely applied. HR results from a measurement campaign on 8 healthy subjects have shown, with respect to ECG, deviations (calculated as 2σ) of ±3.3 bpm, ±2.3 bpm and ±1.5 bpm for PCG, PPG and VCG, respectively. In conclusion, it is possible to state that the adopted algorithm is able to measure HR accurately from different biosignals. Future work will involve the extraction of additional morphological features in order to characterise the waveforms more deeply and to better describe the subject’s health status.
2014-01-01
Introduction We evaluate an innovative device consisting of an enteral feeding tube equipped with a photoplethysmography (PPG) sensor in contact with the duodenal mucosa. This study aims to determine if the PPG signal, composed of a continuous (PDC) and a pulsatile part (PAC), is a reliable method to assess gut perfusion in a porcine model of septic shock. Method Fourteen piglets were anesthetized and mechanically ventilated. They were randomly assigned to two groups: the nonseptic (NS) group received an infusion of Ringer’s lactate solution (RL) alone, the septic (S) group received in addition a suspension of live Pseudomonas aeruginosa. Heart rate (HR), pulse oximetry (SpO2), mean arterial pressure (MAP), cardiac index (CI) and serum lactates were recorded and gut microcirculation (GM) was monitored with a laser Doppler probe applied on the duodenal serosa. PDC and PAC were given by the PPG probe inserted in the duodenum. Data was collected every 15 minutes (t0, t15…) during 150 minutes (t150). After administration of the bacteria suspension (t0), resuscitation maneuvers were performed following a defined algorithm. GM PAC, and PDC were expressed as variation from baseline (GMvar, PACvar, PDCvar). Analysis of variance (ANOVA) with repeated measures was performed to compare hemodynamic variables, with Bonferroni correction as post hoc analysis on t0, t60 and t150. Results One piglet was withdrawn from analysis due to a defective probe. S group (six piglets) received resuscitation therapy while NS group (seven piglets) did not. A significant group effect was found for the all parameters except HR. Post hoc analysis found a significant decrease for GM and PAC at t60. The correlation between PAC, PDC and microcirculatory parameters were as follows: rPACvar-GMvar = 0.496, P <0.001, rPDCvar-GMvar = 0.244; P = 0.002. In the septic group, correlations were as follows: rPAC-lactate = -0.772, P <0.001; rPDC-lactate = -0.681, P <0.01). At the onset of shock, a decrease of PAC, PDC and GM occurred before the alteration of MAP. Conclusions PAC and PDC decreased at the onset of shock and were correlated with GM and lactate. These results confirm that PPG signal reliably reflects the early perfusion alteration of the gut. Further studies should assess the clinical use of this device. PMID:25030376
Shin, Hangsik
2016-12-01
Pulse rate variability (PRV) is a promising physiological and analytic technique used as a substitute for heart rate variability (HRV). PRV is measured by pulse wave from various devices including mobile and wearable devices but HRV is only measured by an electrocardiogram (ECG). The purpose of this study was to evaluate PRV and HRV at various ambient temperatures and elaborate on the interchangeability of PRV and HRV. Twenty-eight healthy young subjects were enrolled in the experiment. We prepared temperature-controlled rooms and recorded the ECG and photoplethysmography (PPG) under temperature-controlled, constant humidity conditions. The rooms were kept at 17, 25, and 38 °C as low, moderate, and high ambient temperature environments, respectively. HRV and PRV were derived from the synchronized ECG and PPG measures and they were studied in time and frequency domain analysis for PRV/HRV ratio and pulse transit time (PTT). Similarity and differences between HRV and PRV were determined by a statistical analysis. PRV/HRV ratio analysis revealed that there was a significant difference between HRV and PRV for a given ambient temperature; this was with short-term variability measures such as SDNN SDSD or RMSSD, and HF-based variables including HF, LF/HF and normalized HF. In our analysis the absolute value of PTT was not significantly influenced by temperature. Standard deviation of PTT, however, showed significant difference not only between low and moderate temperatures but also between low and high temperatures. Our results suggest that ambient temperature induces a significant difference in PRV compared to HRV and that the difference becomes greater at a higher ambient temperature.
Universal design of a microcontroller and IoT system to detect the heart rate
NASA Astrophysics Data System (ADS)
Uwamahoro, Raphael; Mushikiwabeza, Alexie; Minani, Gerard; Mohan Murari, Bhaskar
2017-11-01
Heart rate analysis provides vital information of the present condition of the human body. It helps medical professionals in diagnosis of various malfunctions of the body. The limitation of vision impaired and blind people to access medical devices cause a considerable loss of life. In this paper, we intended to develop a heart rate detection system that is usable for people with normal and abnormal vision. The system is based on a non-invasive method of measuring the variation of the tissue blood flow rate by means of a photo transmitter and detector through fingertip known as photoplethysmography (PPG). The signal detected is firstly passed through active low pass filter and then amplified by a two stages high gain amplifier. The amplified signal is feed into the microcontroller to calculate the heart rate and displays the heart beat via sound systems and Liquid Crystal Display (LCD). To distinguish arrhythmia, normal heart rate and abnormal working conditions of the system, recognition is provided in different sounds, LCD readings and Light Emitting Diodes (LED).
Flexible heartbeat sensor for wearable device.
Kwak, Yeon Hwa; Kim, Wonhyo; Park, Kwang Bum; Kim, Kunnyun; Seo, Sungkyu
2017-08-15
We demonstrate a flexible strain-gauge sensor and its use in a wearable application for heart rate detection. This polymer-based strain-gauge sensor was fabricated using a double-sided fabrication method with polymer and metal, i.e., polyimide and nickel-chrome. The fabrication process for this strain-gauge sensor is compatible with the conventional flexible printed circuit board (FPCB) processes facilitating its commercialization. The fabricated sensor showed a linear relation for an applied normal force of more than 930 kPa, with a minimum detectable force of 6.25Pa. This sensor can also linearly detect a bending radius from 5mm to 100mm. It is a thin, flexible, compact, and inexpensive (for mass production) heart rate detection sensor that is highly sensitive compared to the established optical photoplethysmography (PPG) sensors. It can detect not only the timing of heart pulsation, but also the amplitude or shape of the pulse signal. The proposed strain-gauge sensor can be applicable to various applications for smart devices requiring heartbeat detection. Copyright © 2017 Elsevier B.V. All rights reserved.
Pirbhulal, Sandeep; Zhang, Heye; Mukhopadhyay, Subhas Chandra; Li, Chunyue; Wang, Yumei; Li, Guanglin; Wu, Wanqing; Zhang, Yuan-Ting
2015-01-01
Body Sensor Network (BSN) is a network of several associated sensor nodes on, inside or around the human body to monitor vital signals, such as, Electroencephalogram (EEG), Photoplethysmography (PPG), Electrocardiogram (ECG), etc. Each sensor node in BSN delivers major information; therefore, it is very significant to provide data confidentiality and security. All existing approaches to secure BSN are based on complex cryptographic key generation procedures, which not only demands high resource utilization and computation time, but also consumes large amount of energy, power and memory during data transmission. However, it is indispensable to put forward energy efficient and computationally less complex authentication technique for BSN. In this paper, a novel biometric-based algorithm is proposed, which utilizes Heart Rate Variability (HRV) for simple key generation process to secure BSN. Our proposed algorithm is compared with three data authentication techniques, namely Physiological Signal based Key Agreement (PSKA), Data Encryption Standard (DES) and Rivest Shamir Adleman (RSA). Simulation is performed in Matlab and results suggest that proposed algorithm is quite efficient in terms of transmission time utilization, average remaining energy and total power consumption. PMID:26131666
Pirbhulal, Sandeep; Zhang, Heye; Mukhopadhyay, Subhas Chandra; Li, Chunyue; Wang, Yumei; Li, Guanglin; Wu, Wanqing; Zhang, Yuan-Ting
2015-06-26
Body Sensor Network (BSN) is a network of several associated sensor nodes on, inside or around the human body to monitor vital signals, such as, Electroencephalogram (EEG), Photoplethysmography (PPG), Electrocardiogram (ECG), etc. Each sensor node in BSN delivers major information; therefore, it is very significant to provide data confidentiality and security. All existing approaches to secure BSN are based on complex cryptographic key generation procedures, which not only demands high resource utilization and computation time, but also consumes large amount of energy, power and memory during data transmission. However, it is indispensable to put forward energy efficient and computationally less complex authentication technique for BSN. In this paper, a novel biometric-based algorithm is proposed, which utilizes Heart Rate Variability (HRV) for simple key generation process to secure BSN. Our proposed algorithm is compared with three data authentication techniques, namely Physiological Signal based Key Agreement (PSKA), Data Encryption Standard (DES) and Rivest Shamir Adleman (RSA). Simulation is performed in Matlab and results suggest that proposed algorithm is quite efficient in terms of transmission time utilization, average remaining energy and total power consumption.
Safety assessment of propylene glycol, tripropylene glycol, and PPGs as used in cosmetics.
Fiume, Monice M; Bergfeld, Wilma F; Belsito, Donald V; Hill, Ronald A; Klaassen, Curtis D; Liebler, Daniel; Marks, James G; Shank, Ronald C; Slaga, Thomas J; Snyder, Paul W; Andersen, F Alan
2012-01-01
Propylene glycol is an aliphatic alcohol that functions as a skin conditioning agent, viscosity decreasing agent, solvent, and fragrance ingredient in cosmetics. Tripropylene glycol functions as a humectant, antioxidant, and emulsion stabilizer. Polypropylene glycols (PPGs), including PPG-3, PPG-7, PPG-9, PPG-12, PPG-13, PPG-15, PPG-16, PPG-17, PPG-20, PPG-26, PPG-30, PPG-33, PPG-34, PPG-51, PPG-52, and PPG-69, function primarily as skin conditioning agents, with some solvent use. The majority of the safety and toxicity information presented is for propylene glycol (PG). Propylene glycol is generally nontoxic and is noncarcinogenic. Clinical studies demonstrated an absence of dermal sensitization at use concentrations, although concerns about irritation remained. The CIR Expert Panel determined that the available information support the safety of tripropylene glycol as well as all the PPGs. The Expert Panel concluded that PG, tripropylene glycol, and PPGs ≥3 are safe as used in cosmetic formulations when formulated to be nonirritating.
Östling, Gerd; Nilsson, Peter M.
2015-01-01
Introduction Arterial stiffness is an independent risk factor for cardiovascular morbidity and can be assessed by applanation tonometry by measuring pulse wave velocity (PWV) and augmentation index (AIX) by pressure pulse wave analysis (PWA). As an inexpensive and operator independent alternative, photoelectric plethysmography (PPG) has been introduced with analysis of the digital volume pulse wave (DPA) and its second derivatives of wave reflections. Objective The objective was to investigate the repeatability of arterial stiffness parameters measured by digital pulse wave analysis (DPA) and the associations to applanation tonometry parameters. Methods and Results 112 pregnant and non-pregnant individuals of different ages and genders were examined with SphygmoCor arterial wall tonometry and Meridian DPA finger photoplethysmography. Coefficients of repeatability, Bland-Altman plots, intraclass correlation coefficients and correlations to heart rate (HR) and body height were calculated for DPA variables, and the DPA variables were compared to tonometry variables left ventricular ejection time (LVET), PWV and AIX. No DPA variable showed any systematic measurement error or excellent repeatability, but dicrotic index (DI), dicrotic dilatation index (DDI), cardiac ejection elasticity index (EEI), aging index (AI) and second derivatives of the crude pulse wave curve, b/a and e/a, showed good repeatability. Overall, the correlations to AIX were better than to PWV, with correlations coefficients >0.70 for EEI, AI and b/a. Considering the level of repeatability and the correlations to tonometry, the overall best DPA parameters were EEI, AI and b/a. The two pansystolic time parameters, ejection time compensated (ETc) by DPA and LVET by tonometry, showed a significant but weak correlation. Conclusion For estimation of the LV function, ETc, EEI and b/a are suitable, for large artery stiffness EEI, and for small arteries DI and DDI. The only global parameter, AI, showed a high repeatability and the overall best correlations with AIX and PWV. PMID:26291079
Kamshilin, Alexei A; Volynsky, Maxim A; Khayrutdinova, Olga; Nurkhametova, Dilyara; Babayan, Laura; Amelin, Alexander V; Mamontov, Oleg V; Giniatullin, Rashid
2018-06-18
The non-invasive biomarkers of migraine can help to develop the personalized medication of this disorder. In testing of the antimigraine drugs the capsaicin-induced skin redness with activated TRPV1 receptors in sensory neurons associated with the release of the migraine mediator CGRP has already been widely used. Fourteen migraine patients (mean age 34.6 ± 10.2 years) and 14 healthy volunteers (mean age 29.9 ± 9.7 years) participated in the experiment. A new arrangement of imaging photoplethysmography recently developed by us was used here to discover novel sensitive parameters of dermal blood flow during capsaicin applications in migraine patients. Blood pulsation amplitude (BPA) observed as optical-intensity waveform varying synchronously with heartbeat was used for detailed exploration of microcirculatory perfusion induced by capsicum patch application. The BPA signals, once having appeared after certain latent period, were progressively rising until being saturated. Capsaicin-induced high BPA areas were distributed unevenly under the patch, forming "hot spots." Interestingly the hot spots were much more variable in migraine patients than in the control group. In contrast to BPA, a slow component of waveforms related to the skin redness changed significantly less than BPA highlighting the latter parameter as the potential sensitive biomarker of capsaicin-induced activation of the blood flow. Thus, in migraine patients, there is a non-uniform (both in space and in time) reaction to capsaicin, resulting in highly variable openings of skin capillaries. BPA dynamics measured by imaging photoplethysmography could serve as a novel sensitive non-invasive biomarker of migraine-associated changes in microcirculation.
NASA Astrophysics Data System (ADS)
Ghijsen, Michael T.; Tromberg, Bruce J.
2017-03-01
Affixed Transmission Speckle Analysis (ATSA) is a method recently developed to measure blood flow that is based on laser speckle imaging miniaturized into a clip-on form factor the size of a pulse-oximeter. Measuring at a rate of 250 Hz, ATSA is capable or obtaining the cardiac waveform in blood flow data, referred to as the Speckle-Plethysmogram (SPG). ATSA is also capable of simultaneously measuring the Photoplethysmogram (PPG), a more conventional signal related to light intensity. In this work we present several novel algorithms for extracting physiologically relevant information from the combined SPG-PPG waveform data. First we show that there is a slight time-delay between the SPG and PPG that can be extracted computationally. Second, we present a set of frequency domain algorithms that measure harmonic content on pulse-by-pulse basis for both the SPG and PPG. Finally, we apply these algorithms to data obtained from a set of subjects including healthy controls and individuals with heightened cardiovascular risk. We hypothesize that the time-delay and frequency content are correlated with cardiovascular health; specifically with vascular stiffening.
Detection of physiological changes after exercise via a remote optophysiological imaging system
NASA Astrophysics Data System (ADS)
Sun, Yu; Hu, Sijung; Azorin-Peris, Vicente; Zheng, Jia; Greenwald, Stephen; Chambers, Jonathon; Zhu, Yisheng
2011-03-01
A study of blood perfusion mapping was performed with a remote opto-physiological imaging (OPI) system coupling a sensitive CMOS camera and a custom-built resonant cavity light emitting diode (RCLED) ringlight. The setup is suitable for the remote assessment of blood perfusion in tissue over a wide range of anatomical locations. The purpose of this study is to evaluate the reliability and stability of the OPI system when measuring a cardiovascular variable of clinical interest, in this case, heart rate. To this end, the non-contact and contact photoplethysmographic (PPG) signals obtained from the OPI system and conventional PPG sensor were recorded simultaneously from each of 12 subjects before and after 5-min of cycling exercise. The time-frequency representation (TFR) method was used to visualize the time-dependent behavior of the signal frequency. The physiological parameters derived from the images captured by the OPI system exhibit comparable functional characteristics to those taken from conventional contact PPG pulse waveform measurements in both the time and frequency domains. Finally and more importantly, a previously developed opto-physiological model was employed to provide a 3-D representation of blood perfusion in human tissue which could provide a new insight into clinical assessment and diagnosis of circulatory pathology in various tissue segments.
Zhang, Xuezheng; Kassem, Mahmoud Attia Mohamed; Zhou, Ying; Shabsigh, Muhammad; Wang, Quanguang; Xu, Xuzhong
2017-01-01
Obstructive sleep apnea (OSA) is one of the important risk factors contributing to postoperative airway complications. OSA alters the respiratory physiology and increases the sensitivity of muscle tone of the upper airway after surgery to residual anesthetic medication. In addition, the prevalence of OSA was reported to be much higher among surgical patients than the general population. Therefore, appropriate monitoring to detect early respiratory impairment in postoperative extubated patients with possible OSA is challenging. Based on the comprehensive clinical observation, several equipment have been used for monitoring the respiratory conditions of OSA patients after surgery, including the continuous pulse oximetry, capnography, photoplethysmography (PPG), and respiratory volume monitor (RVM). To date, there has been no consensus on the most suitable device as a recommended standard of care. In this review, we describe the advantages and disadvantages of some possible monitoring strategies under certain clinical conditions. According to the literature, the continuous pulse oximetry, with its high sensitivity, is still the most widely used device. It is also cost-effective and convenient to use but has low specificity and does not reflect ventilation. Capnography is the most widely used device for detection of hypoventilation, but it may not provide reliable data for extubated patients. Even normal capnography cannot exclude the existence of hypoxia. PPG shows the state of both ventilation and oxygenation, but its sensitivity needs further improvement. RVM provides real-time detection of hypoventilation, quantitative precise demonstration of respiratory rate, tidal volume, and MV for extubated patients, but no reflection of oxygenation. Altogether, the sole use of any of these devices is not ideal for monitoring of extubated patients with or at risk for OSA after surgery. However, we expect that the combined use of continuous pulse oximetry and RVM may be promising for these patients due to their complementary function, which need further study. PMID:28337439
Lee, Ji-Hyun; Yang, Seungman; Park, Jonghyun; Kim, Hee Chan; Kim, Eun-Hee; Jang, Young-Eun; Kim, Jin-Tae; Kim, Hee-Soo
2018-06-19
Respiratory variations in photoplethysmography amplitude enable volume status assessment. However, the contact force between the measurement site and sensor can affect photoplethysmography waveforms. We aimed to evaluate contact force effects on respiratory variations in photoplethysmography waveforms in children under general anesthesia. Children aged 3-5 years were enrolled. After anesthetic induction, mechanical ventilation commenced at a tidal volume of 10 mL/kg. Photoplethysmographic signals were obtained in the supine position from the index finger using a force sensor-integrated clip-type photoplethysmography sensor that increased the contact force from 0-1.4 N for 20 respiratory cycles at each force. The AC amplitude (pulsatile component), DC amplitude (nonpulsatile component), AC/DC ratio, and respiratory variations in photoplethysmography amplitude were calculated. Data from 34 children were analyzed. Seven contact forces at 0.2-N increments were evaluated for each patient. The normalized AC amplitude increased maximally at a contact force of 0.4-0.6 N and decreased with increasing contact force. However, the normalized DC amplitude increased with a contact force exceeding 0.4 N. ΔPOP decreased slightly and increased from the point when the AC amplitude started to decrease as contact force increased. In a 0.2-1.2 N contact force range, significant changes in the normalized AC amplitude, normalized DC amplitude, AC/DC ratio, and respiratory variations in photoplethysmography amplitude were observed. Respiratory variations in photoplethysmography amplitude changed according to variable contact forces; therefore, these measurements may not reflect respiration-induced stroke volume variations. Clinicians should consider contact force bias when interpreting morphological data from photoplethysmography signals. © 2018 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Wei, Lv; Yi, Long; Song, Fanbo; Wei, Chao; Wang, Bai-Fan; Xi, Zhen
2014-04-01
Hydrogen sulfide (H2S) is an endogenously produced gaseous signalling molecule with multiple biological functions. In order to visualize and quantify the endogenous in situ production of H2S in living cells, here we developed two new sulphide ratiometric probes (SR400 and SR550) based on fluorescence resonance energy transfer (FRET) strategy for live capture of H2S. The FRET-based probes show excellent selectivity toward H2S in a high thiol background under physiological buffer. The probe can be used to in situ visualize cysteine-dependent H2S production in a chiral-sensitive manner in living cells. The ratiometric imaging studies indicated that D-Cys induces more H2S production than that of L-Cys in mitochondria of human embryonic kidney 293 cells (HEK293). The cysteine mimics propargylglycine (PPG) has also been found to inhibit the cysteine-dependent endogenous H2S production in a chiral-sensitive manner in living cells. D-PPG inhibited D-Cys-dependent H2S production more efficiently than L-PPG, while, L-PPG inhibited L-Cys-dependent H2S production more efficiently than D-PPG. Our bioimaging studies support Kimura's discovery of H2S production from D-cysteine in mammalian cells and further highlight the potential of D-cysteine and its derivatives as an alternative strategy for classical H2S-releasing drugs.
Silva-Junior, Gilberto; Turon, Fanny; Baiges, Anna; Cerda, Eira; García-Criado, Ángeles; Blasi, Annabel; Torres, Ferran; Hernandez-Gea, Virginia; Bosch, Jaume; Garcia-Pagan, Juan Carlos
2017-05-01
A reduction in portal pressure gradient (PPG) to <12 mm Hg after placement of a transjugular intrahepatic portosystemic shunt (TIPS) correlates with the absence of further bleeding or ascites at follow-up examinations of patients with cirrhosis. The PPG is usually measured immediately after placement of the TIPS, when different circumstances can affect PPG values, which could affect determination of risk for decompensation. We investigated variations in PPG measurements collected at different time points after TIPS, aiming to identify a time point after which PPG values were best maintained. We performed a retrospective study of 155 consecutive patients with severe complications of portal hypertension who received placement of TIPS from January 2008 through October 2015; patients were followed until March 2016. We compared PPG values measured at different time points and under different conditions: immediately after placement of TIPS (immediate PPG); at least 24 hours after placement to TIPS into hemodynamically stable patients, without sedation (early PPG); and again 1 month after TIPS placement (late PPG). The immediate PPG differed significantly from the early PPG, regardless of whether the TIPS was placed using general anesthesia (8.5 ± 3.5 mm Hg vs 10 ± 3.5 mm Hg; P = .015) or deep sedation (12 ± 4 mm Hg vs 10.5 ± 4 mm Hg; P <.001). In considering the 12 mm Hg threshold, concordance between immediate PPG and early PPG values was poor. However, there was no significant difference between mean early PPG and late PPG values (8.5 ± 2.5 mm Hg vs 8 ± 3 mm Hg), or between proportions of patients with early PPG vs late PPG values <12 mm Hg threshold. Maintenance of a PPG value <12 mm Hg during the follow-up period was associated with a lower risk of recurrent or de novo variceal bleeding or ascites (hazard ratio, 0.11; 95% confidence interval, 0.04 0.27; P < .001). In a retrospective study of patients with PPG values measured at different time points after TIPS placement, we found measurements of PPG in awake, hemodynamically stable patients at least 24 hours after TIPS to be the best maintained values. Our findings support the concept that PPG value <12 mm Hg after TIPS placement is associated with reduced risk of bleeding and ascites. Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.
Lanigan, R S
2001-01-01
The Polypropylene Glycol (PPG) Butyl Ethers function as skinand hair-conditioning agents in cosmetics. Intestinal absorption of the PPG Butyl Ethers was inversely proportional to the molecular weight. In general, the toxicity of the PPG Butyl Ethers decreased as the molecular weight increased. In acute studies, moderate intraperitoneal (IP) doses of various PPG Butyl Ethers caused convulsive seizures in mice and anesthetized dogs, and large oral doses caused decreased activity, anuria, renal tubular swelling and necrosis, and hepatic swelling and necrosis. PPG-2 Butyl Ether vapors were nontoxic by the inhalation route. PPG-2 Butyl Ether was nontoxic in short-term feeding and dermal exposure studies in rats. In animal irritation studies, PPG-2 Butyl Ether caused minor, transient erythema and desquamation; in addition, erythema, edema, ecchymosis, necrosis, and other changes were observed during an acute percutaneous study. PPG-2 Butyl Ether also caused minor to moderate conjunctival irritation and minor corneal injury. PPG-2 Butyl Ether when dermally applied was nontoxic to pregnant rats and was nonteratogenic at doses up to 1.0 ml/kg/day. PPG BE800 at concentrations of 0.001% to 0.26% in feed was noncarcinogenic to rats after 2 years of treatment. In clinical studies, PPG BE800 was nonirritating and nonsensitizing to the skin when tested using 200 subjects. PPG-40 Butyl Ether was neither an irritant nor a sensitizer in a repeat-insult patch test using 112 subjects. Although clinical testing did not indicate significant skin irritation is produced by these ingredients, the animal test data did indicate the potential that these ingredients can be irritating. Therefore, it was concluded that the PPG Butyl Ethers can be used safely in cosmetic products if they are formulated to avoid irritation. Data on the component ingredients, Propylene Glycol, PPG, and n-Butyl Alcohol, from previous cosmetic ingredient safety assessments were also considered and found to support the safety of PPG Butyl Ethers.
Giassi, Pedro; Okida, Sergio; Oliveira, Maurício G; Moraes, Raimes
2013-11-01
Short-term cardiovascular regulation mediated by the sympathetic and parasympathetic branches of the autonomic nervous system has been investigated by multivariate autoregressive (MVAR) modeling, providing insightful analysis. MVAR models employ, as inputs, heart rate (HR), systolic blood pressure (SBP) and respiratory waveforms. ECG (from which HR series is obtained) and respiratory flow waveform (RFW) can be easily sampled from the patients. Nevertheless, the available methods for acquisition of beat-to-beat SBP measurements during exams hamper the wider use of MVAR models in clinical research. Recent studies show an inverse correlation between pulse wave transit time (PWTT) series and SBP fluctuations. PWTT is the time interval between the ECG R-wave peak and photoplethysmography waveform (PPG) base point within the same cardiac cycle. This study investigates the feasibility of using inverse PWTT (IPWTT) series as an alternative input to SBP for MVAR modeling of the cardiovascular regulation. For that, HR, RFW, and IPWTT series acquired from volunteers during postural changes and autonomic blockade were used as input of MVAR models. Obtained results show that IPWTT series can be used as input of MVAR models, replacing SBP measurements in order to overcome practical difficulties related to the continuous sampling of the SBP during clinical exams.
Analysis of physiological signals for recognition of boredom, pain, and surprise emotions.
Jang, Eun-Hye; Park, Byoung-Jun; Park, Mi-Sook; Kim, Sang-Hyeob; Sohn, Jin-Hun
2015-06-18
The aim of the study was to examine the differences of boredom, pain, and surprise. In addition to that, it was conducted to propose approaches for emotion recognition based on physiological signals. Three emotions, boredom, pain, and surprise, are induced through the presentation of emotional stimuli and electrocardiography (ECG), electrodermal activity (EDA), skin temperature (SKT), and photoplethysmography (PPG) as physiological signals are measured to collect a dataset from 217 participants when experiencing the emotions. Twenty-seven physiological features are extracted from the signals to classify the three emotions. The discriminant function analysis (DFA) as a statistical method, and five machine learning algorithms (linear discriminant analysis (LDA), classification and regression trees (CART), self-organizing map (SOM), Naïve Bayes algorithm, and support vector machine (SVM)) are used for classifying the emotions. The result shows that the difference of physiological responses among emotions is significant in heart rate (HR), skin conductance level (SCL), skin conductance response (SCR), mean skin temperature (meanSKT), blood volume pulse (BVP), and pulse transit time (PTT), and the highest recognition accuracy of 84.7% is obtained by using DFA. This study demonstrates the differences of boredom, pain, and surprise and the best emotion recognizer for the classification of the three emotions by using physiological signals.
Gonzalez Viejo, Claudia; Fuentes, Sigfredo; Torrico, Damir D; Dunshea, Frank R
2018-06-03
Traditional methods to assess heart rate (HR) and blood pressure (BP) are intrusive and can affect results in sensory analysis of food as participants are aware of the sensors. This paper aims to validate a non-contact method to measure HR using the photoplethysmography (PPG) technique and to develop models to predict the real HR and BP based on raw video analysis (RVA) with an example application in chocolate consumption using machine learning (ML). The RVA used a computer vision algorithm based on luminosity changes on the different RGB color channels using three face-regions (forehead and both cheeks). To validate the proposed method and ML models, a home oscillometric monitor and a finger sensor were used. Results showed high correlations with the G color channel (R² = 0.83). Two ML models were developed using three face-regions: (i) Model 1 to predict HR and BP using the RVA outputs with R = 0.85 and (ii) Model 2 based on time-series prediction with HR, magnitude and luminosity from RVA inputs to HR values every second with R = 0.97. An application for the sensory analysis of chocolate showed significant correlations between changes in HR and BP with chocolate hardness and purchase intention.
Non-contact detection of cardiac rate based on visible light imaging device
NASA Astrophysics Data System (ADS)
Zhu, Huishi; Zhao, Yuejin; Dong, Liquan
2012-10-01
We have developed a non-contact method to detect human cardiac rate at a distance. This detection is based on the general lighting condition. Using the video signal of human face region captured by webcam, we acquire the cardiac rate based on the PhotoPlethysmoGraphy theory. In this paper, the cardiac rate detecting method is mainly in view of the blood's different absorptivities of the lights various wavelengths. Firstly, we discompose the video signal into RGB three color signal channels and choose the face region as region of interest to take average gray value. Then, we draw three gray-mean curves on each color channel with time as variable. When the imaging device has good fidelity of color, the green channel signal shows the PhotoPlethysmoGraphy information most clearly. But the red and blue channel signals can provide more other physiological information on the account of their light absorptive characteristics of blood. We divide red channel signal by green channel signal to acquire the pulse wave. With the passband from 0.67Hz to 3Hz as a filter of the pulse wave signal and the frequency spectrum superimposed algorithm, we design frequency extracted algorithm to achieve the cardiac rate. Finally, we experiment with 30 volunteers, containing different genders and different ages. The results of the experiments are all relatively agreeable. The difference is about 2bmp. Through the experiment, we deduce that the PhotoPlethysmoGraphy theory based on visible light can also be used to detect other physiological information.
Vergara, Alessandro; Corvino, Ermanno; Sorrentino, Giosué; Piccolo, Chiara; Tortora, Alessandra; Carotenuto, Luigi; Mazzarella, Lelio; Zagari, Adriana
2002-10-01
Single chains of the collagen model polypeptide with sequence (Pro-Pro-Gly)(10), hereafter referred to as (PPG)(10), aggregate to form rod-shaped triple helices. Crystals of (PPG)(10) were grown in the Advanced Protein Crystallization Facility (APCF) both onboard the International Space Station (ISS) and on Earth. The experiments allow the direct comparison of four different crystallization environments for the first time: solution in microgravity ((g), agarose gel in (g, solution on earth, and gel on earth. Both on board and on ground, the crystal growth was monitored by a CCD video camera. The image analysis provided information on the spatial distribution of the crystals, their movement and their growth rate. The analysis of the distribution of crystals reveals that the crystallization process occurs as it does in batch conditions. Slow motions have been observed onboard the ISS. Different to Space-Shuttle experiment, the crystals onboard the ISS moved coherently and followed parallel trajectories. Growth rate and induction time are very similar both in gel and in solution, suggesting that the crystal growth rate is controlled by the kinetics at the interface under the used experimental conditions. These results provide the first data in the crystallogenesis of (PPG)(10), which is a representative member of non-globular, rod-like proteins.
Measuring Pulse Rate Variability using Long-Range, Non-Contact Imaging Photoplethysmography
2016-08-20
subject distances. In this study, video was recorded from 19 participants, while at rest, at a distance of 25 meters from the imaging sensor. A...subject distances of no more than 3 meters . This study demonstrates that pulse rates of less than one beat-per-minute error can be obtained when the...be achieved at long imager-to-subject distances. In this study, video was recorded from 19 participants, while at rest, at a distance of 25 meters
Liu, Jing; Li, Yao; Ding, Xiao-Rong; Dai, Wen-Xuan; Zhang, Yuan-Ting
2015-01-01
Pulse transit time (PTT), which refers to the time it takes a pulse wave to travel between two arterial sites is a promising index for cuff-less blood pressure (BP) estimation, as well as non-invasive assessment of arterial functions. However, it has not been investigated whether PTTs measured from ECG and different wavelength PPG are equally affected by the arterial status. Furthermore, comparison between the changes of different PTTs can provide enlightenment on the hardware implementation of the PTT-based BP estimation method. This work mainly studied the changes of PTTs calculated from electrocardiogram (ECG) and multi-wavelength photoplethysmogram (PPG) after exerting cuff pressure on the upper arm. A four-channel PPG acquisition system was developed to collect the multi-wavelength PPG signals of red, yellow, green and blue light at the fingertip simultaneously. Ten subjects participated in the experiment and their PTTs measured from different PPG and ECG signals before and after exerting cuff pressure were compared. This study found that within one minute after the four-minute cuff inflation and deflation process, the PTT measured from ECG and yellow PPG experienced a significant increase (p<;0.05) while the PTT from ECG and blue PPG had no statistical difference (p>0.9) compared with that before exerting cuff pressure. This indicates that PTTs calculated from different wavelength PPG have different recoverability from smooth muscle relaxation. Another interesting finding is that the PTT calculated from ECG and yellow PPG had a strong correlation (|r|>0.7) with the time difference between yellow PPG and other PPG signals, which implies the potential of the time difference between yellow PPG and other PPGs as a complementary to PTT-based model for blood pressure estimation.
NASA Astrophysics Data System (ADS)
Blackford, Ethan B.; Estepp, Justin R.
2015-03-01
Non-contact, imaging photoplethysmography uses cameras to facilitate measurements including pulse rate, pulse rate variability, respiration rate, and blood perfusion by measuring characteristic changes in light absorption at the skin's surface resulting from changes in blood volume in the superficial microvasculature. Several factors may affect the accuracy of the physiological measurement including imager frame rate, resolution, compression, lighting conditions, image background, participant skin tone, and participant motion. Before this method can gain wider use outside basic research settings, its constraints and capabilities must be well understood. Recently, we presented a novel approach utilizing a synchronized, nine-camera, semicircular array backed by measurement of an electrocardiogram and fingertip reflectance photoplethysmogram. Twenty-five individuals participated in six, five-minute, controlled head motion artifact trials in front of a black and dynamic color backdrop. Increasing the input channel space for blind source separation using the camera array was effective in mitigating error from head motion artifact. Herein we present the effects of lower frame rates at 60 and 30 (reduced from 120) frames per second and reduced image resolution at 329x246 pixels (one-quarter of the original 658x492 pixel resolution) using bilinear and zero-order downsampling. This is the first time these factors have been examined for a multiple imager array and align well with previous findings utilizing a single imager. Examining windowed pulse rates, there is little observable difference in mean absolute error or error distributions resulting from reduced frame rates or image resolution, thus lowering requirements for systems measuring pulse rate over sufficient length time windows.
NASA Astrophysics Data System (ADS)
Liopo, Anton; Su, Richard; Tsyboulski, Dmitri A.; Oraevsky, Alexander A.
2016-08-01
Enhanced delivery of optical clearing agents (OCA) through skin may improve sensitivity of optical and optoacoustic (OA) methods of imaging, sensing, and monitoring. This report describes a two-step method for enhancement of light penetration through skin. Here, we demonstrate that topical application of hyaluronic acid (HA) improves skin penetration of hydrophilic and lipophilic OCA and thus enhances their performance. We examined the OC effect of 100% polyethylene and polypropylene glycols (PPGs) and their mixture after pretreatment by HA, and demonstrated significant increase in efficiency of light penetration through skin. Increased light transmission resulted in a significant increase of OA image contrast in vitro. Topical pretreatment of skin for about 30 min with 0.5% HA in aqueous solution offers effective delivery of low molecular weight OCA such as a mixture of PPG-425 and polyethylene glycol (PEG)-400. The developed approach of pretreatment by HA prior to application of clearing agents (PEG and PPG) resulted in a ˜47-fold increase in transmission of red and near-infrared light and significantly enhanced contrast of OA images.
Management of postprandial glucose: Recommended targets and treatment with biphasic insulin.
Liebl, Andreas
2016-12-01
Increases in glycaemia, particularly following meals, have been independently associated with diabetes complications, most notably cardiovascular disease. Control of postprandial plasma glucose (PPG) therefore plays an important role in diabetes management. International diabetes guidelines acknowledge the value of PPG monitoring yet place relatively little emphasis on PPG control. This article considers the impact of suboptimal PPG control and current recommendations with regard to management of PPG. Specific consideration is given to the role of biphasic insulins, one of the treatment options recognised by the International Diabetes Federation as preferentially lowering PPG levels. Copyright © 2016 Primary Care Diabetes Europe. Published by Elsevier Ltd. All rights reserved.
Li, Yan; Gao, He; Ma, Yan
2017-05-01
High prevalence of obstructive sleep apnea (OSA) has increased the demands for more convenient and accessible diagnostic devices other than standard in-lab polysomnography (PSG). Despite the increasing utility of photoplethysmograph (PPG), it remains understudied in underserved populations. This study aimed to evaluate the reliability of a standard pulse oximeter system with an automated analysis based on the PPG signal for the diagnosis of OSA, as compared with PSG derived measures.Consecutive out-patients with suspect OSA completed a PPG monitoring simultaneous with an overnight in-lab standard PSG. Forty-nine OSA patients (38 males, age 43.5 ± 16.9 years, BMI 26.9 ± 0.5 kg/m) were included in this study. Automated analyses were based on PPG and oximetry signals only. The PPG calculated measures were compared with PSG derived measures for agreement tests.Respiratory events index derived from PPG significantly correlated with PSG-derived apnea-hypopnea index (r = 0.935, P < .001). The calculation of total sleep time and oxygen desaturation index from PPG and PSG also significantly correlated (r = 0.418, P = .003; r = 0.933, P < .001, respectively). Bland-Altman plots showed good agreement between the PPG and the PSG measures. The overall sensitivity and specificity of PPG are good, especially in moderate and severe OSA groups.The tested PPG approach yielded acceptable results compared to the gold standard PSG among moderate to severe OSA patients. A pulse oximeter system with PPG recording can be used for the diagnosis or screening of OSA in high risk population.
NASA Astrophysics Data System (ADS)
Amelard, Robert; Pfisterer, Kaylen J.; Jagani, Shubh; Clausi, David A.; Wong, Alexander
2018-02-01
Obstructive sleep apnea (OSA) affects 20% of the adult population, and is associated with cardiovascular and cognitive morbidities. However, it is estimated that up to 80% of treatable OSA cases remain undiagnosed. Cur- rent methods for diagnosing OSA are expensive, labor-intensive, and involve uncomfortable wearable sensors. This study explored the feasibility of non-contact biophotonic assessment of OSA cardiovascular biomarkers via photoplethysmography imaging (PPGI). In particular, PPGI was used to monitor the hemodynamic response to obstructive respiratory events. Sleep apnea onset was simulated using Muller's maneuver in which breathing was obstructed by a respiratory clamp. A custom PPGI system, coded hemodynamic imaging (CHI), was positioned 1 m above the bed and illuminated the participant's head with 850 nm light, providing non-intrusive illumination for night-time monitoring. A video was recorded before, during and following an apnea event at 60 fps, yielding 17 ms temporal resolution. Per-pixel absorbance signals were extracted using a Beer-Lambert derived light transport model, and subsequently denoised. The extracted hemodynamic signal exhibited dynamic temporal modulation during and following the apnea event. In particular, the pulse wave amplitude (PWA) decreased during obstructed breathing, indicating vasoconstriction. Upon successful inhalation, the PWA gradually increased toward homeostasis following a temporal phase delay. This temporal vascular tone modulation provides insight into autonomic and vascular response, and may be used to assess sleep apnea using non-contact biophotonic imaging.
Remer, Itay; Bilenca, Alberto
2015-11-01
Photoplethysmography is a well-established technique for the noninvasive measurement of blood pulsation. However, photoplethysmographic devices typically need to be in contact with the surface of the tissue and provide data from a single contact point. Extensions of conventional photoplethysmography to measurements over a wide field-of-view exist, but require advanced signal processing due to the low signal-to-noise-ratio of the photoplethysmograms. Here, we present a noncontact method based on temporal sampling of time-integrated speckle using a camera-phone for noninvasive, widefield measurements of physiological parameters across the human fingertip including blood pulsation and resting heart-rate frequency. The results show that precise estimation of these parameters with high spatial resolution is enabled by measuring the local temporal variation of speckle patterns of backscattered light from subcutaneous skin, thereby opening up the possibility for accurate high resolution blood pulsation imaging on a camera-phone. Camera-phone laser speckle imager along with measured relative blood perfusion maps of a fingertip showing skin perfusion response to a pulse pressure applied to the upper arm. The figure is for illustration only; the imager was stabilized on a stand throughout the experiments. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Analogue step-by-step DC component eliminator for 24-hour PPG signal monitoring.
Pilt, Kristjan; Meigas, Kalju; Lass, Jaanus; Rosmann, Mart; Kaik, Jüri
2007-01-01
For applications where PPG signal AC component needs to be measured without disturbances in its shape and recorded digitally with high digitalization accuracy, the step-by-step DC component eliminator is developed. This paper describes step-by-step DC component eliminator, which is utilized with analogue comparator and operational amplifier. It allows to record PPG signal without disturbances in its shape in 24-hours PPG signal monitoring system. The experiments with PPG signal have been carried out.
Mayrhofer, Severine; Weber, Jan M.; Pöggeler, Stefanie
2006-01-01
The homothallic, filamentous ascomycete Sordaria macrospora is self-fertile and produces sexual fruiting bodies (perithecia) without a mating partner. Even so, S. macrospora transcriptionally expresses two pheromone-precursor genes (ppg1 and ppg2) and two pheromone-receptor genes (pre1 and pre2). The proteins encoded by these genes are similar to α-factor-like and a-factor-like pheromones and to G-protein-coupled pheromone receptors of the yeast Saccharomyces cerevisiae. It has been suggested that in S. macrospora, PPG1/PRE2 and PPG2/PRE1 form two cognate pheromone–receptor pairs. To investigate their function, we deleted (Δ) pheromone-precursor genes (Δppg1, Δppg2) and receptor genes (Δpre1, Δpre2) and generated single- as well as double-knockout strains. No effect on vegetative growth, fruiting-body, and ascospore development was seen in the single pheromone-mutant and receptor-mutant strains, respectively. However, double-knockout strains lacking any compatible pheromone-receptor pair (Δpre2/Δppg2, Δpre1/Δppg1) and the double-pheromone mutant (Δppg1/Δppg2) displayed a drastically reduced number of perithecia and sexual spores, whereas deletion of both receptor genes (Δpre1/Δpre2) completely eliminated fruiting-body and ascospore formation. The results suggest that pheromones and pheromone receptors are required for optimal sexual reproduction of the homothallic S. macrospora. PMID:16387884
Mayrhofer, Severine; Weber, Jan M; Pöggeler, Stefanie
2006-03-01
The homothallic, filamentous ascomycete Sordaria macrospora is self-fertile and produces sexual fruiting bodies (perithecia) without a mating partner. Even so, S. macrospora transcriptionally expresses two pheromone-precursor genes (ppg1 and ppg2) and two pheromone-receptor genes (pre1 and pre2). The proteins encoded by these genes are similar to alpha-factor-like and a-factor-like pheromones and to G-protein-coupled pheromone receptors of the yeast Saccharomyces cerevisiae. It has been suggested that in S. macrospora, PPG1/PRE2 and PPG2/PRE1 form two cognate pheromone-receptor pairs. To investigate their function, we deleted (delta) pheromone-precursor genes (delta ppg1, delta ppg2) and receptor genes (delta pre1, delta pre2) and generated single- as well as double-knockout strains. No effect on vegetative growth, fruiting-body, and ascospore development was seen in the single pheromone-mutant and receptor-mutant strains, respectively. However, double-knockout strains lacking any compatible pheromone-receptor pair (delta pre2/delta ppg2, delta pre1/delta ppg1) and the double-pheromone mutant (delta ppg1/delta ppg2) displayed a drastically reduced number of perithecia and sexual spores, whereas deletion of both receptor genes (delta pre1/delta pre2) completely eliminated fruiting-body and ascospore formation. The results suggest that pheromones and pheromone receptors are required for optimal sexual reproduction of the homothallic S. macrospora.
Li, Yan; Gao, He; Ma, Yan
2017-01-01
Abstract High prevalence of obstructive sleep apnea (OSA) has increased the demands for more convenient and accessible diagnostic devices other than standard in-lab polysomnography (PSG). Despite the increasing utility of photoplethysmograph (PPG), it remains understudied in underserved populations. This study aimed to evaluate the reliability of a standard pulse oximeter system with an automated analysis based on the PPG signal for the diagnosis of OSA, as compared with PSG derived measures. Consecutive out-patients with suspect OSA completed a PPG monitoring simultaneous with an overnight in-lab standard PSG. Forty-nine OSA patients (38 males, age 43.5 ± 16.9 years, BMI 26.9 ± 0.5 kg/m2) were included in this study. Automated analyses were based on PPG and oximetry signals only. The PPG calculated measures were compared with PSG derived measures for agreement tests. Respiratory events index derived from PPG significantly correlated with PSG-derived apnea–hypopnea index (r = 0.935, P < .001). The calculation of total sleep time and oxygen desaturation index from PPG and PSG also significantly correlated (r = 0.418, P = .003; r = 0.933, P < .001, respectively). Bland–Altman plots showed good agreement between the PPG and the PSG measures. The overall sensitivity and specificity of PPG are good, especially in moderate and severe OSA groups. The tested PPG approach yielded acceptable results compared to the gold standard PSG among moderate to severe OSA patients. A pulse oximeter system with PPG recording can be used for the diagnosis or screening of OSA in high risk population. PMID:28471970
Spinally projecting preproglucagon axons preferentially innervate sympathetic preganglionic neurons
Llewellyn-Smith, I.J.; Marina, N.; Manton, R.N.; Reimann, F.; Gribble, F.M.; Trapp, S.
2015-01-01
Glucagon-like peptide-1 (GLP-1) affects central autonomic neurons, including those controlling the cardiovascular system, thermogenesis, and energy balance. Preproglucagon (PPG) neurons, located mainly in the nucleus tractus solitarius (NTS) and medullary reticular formation, produce GLP-1. In transgenic mice expressing glucagon promoter-driven yellow fluorescent protein (YFP), these brainstem PPG neurons project to many central autonomic regions where GLP-1 receptors are expressed. The spinal cord also contains GLP-1 receptor mRNA but the distribution of spinal PPG axons is unknown. Here, we used two-color immunoperoxidase labeling to examine PPG innervation of spinal segments T1–S4 in YFP-PPG mice. Immunoreactivity for YFP identified spinal PPG axons and perikarya. We classified spinal neurons receiving PPG input by immunoreactivity for choline acetyltransferase (ChAT), nitric oxide synthase (NOS) and/or Fluorogold (FG) retrogradely transported from the peritoneal cavity. FG microinjected at T9 defined cell bodies that supplied spinal PPG innervation. The deep dorsal horn of lower lumbar cord contained YFP-immunoreactive neurons. Non-varicose, YFP-immunoreactive axons were prominent in the lateral funiculus, ventral white commissure and around the ventral median fissure. In T1–L2, varicose, YFP-containing axons closely apposed many ChAT-immunoreactive sympathetic preganglionic neurons (SPN) in the intermediolateral cell column (IML) and dorsal lamina X. In the sacral parasympathetic nucleus, about 10% of ChAT-immunoreactive preganglionic neurons received YFP appositions, as did occasional ChAT-positive motor neurons throughout the rostrocaudal extent of the ventral horn. YFP appositions also occurred on NOS-immunoreactive spinal interneurons and on spinal YFP-immunoreactive neurons. Injecting FG at T9 retrogradely labeled many YFP-PPG cell bodies in the medulla but none of the spinal YFP-immunoreactive neurons. These results show that brainstem PPG neurons innervate spinal autonomic and somatic motor neurons. The distributions of spinal PPG axons and spinal GLP-1 receptors correlate well. SPN receive the densest PPG innervation. Brainstem PPG neurons could directly modulate sympathetic outflow through their spinal inputs to SPN or interneurons. PMID:25450967
Heart Rate Detection Using Microsoft Kinect: Validation and Comparison to Wearable Devices.
Gambi, Ennio; Agostinelli, Angela; Belli, Alberto; Burattini, Laura; Cippitelli, Enea; Fioretti, Sandro; Pierleoni, Paola; Ricciuti, Manola; Sbrollini, Agnese; Spinsante, Susanna
2017-08-02
Contactless detection is one of the new frontiers of technological innovation in the field of healthcare, enabling unobtrusive measurements of biomedical parameters. Compared to conventional methods for Heart Rate (HR) detection that employ expensive and/or uncomfortable devices, such as the Electrocardiograph (ECG) or pulse oximeter, contactless HR detection offers fast and continuous monitoring of heart activities and provides support for clinical analysis without the need for the user to wear a device. This paper presents a validation study for a contactless HR estimation method exploiting RGB (Red, Green, Blue) data from a Microsoft Kinect v2 device. This method, based on Eulerian Video Magnification (EVM), Photoplethysmography (PPG) and Videoplethysmography (VPG), can achieve performance comparable to classical approaches exploiting wearable systems, under specific test conditions. The output given by a Holter, which represents the gold-standard device used in the test for ECG extraction, is considered as the ground-truth, while a comparison with a commercial smartwatch is also included. The validation process is conducted with two modalities that differ for the availability of a priori knowledge about the subjects' normal HR. The two test modalities provide different results. In particular, the HR estimation differs from the ground-truth by 2% when the knowledge about the subject's lifestyle and his/her HR is considered and by 3.4% if no information about the person is taken into account.
Dehkordi, Parastoo; Garde, Ainara; Karlen, Walter; Wensley, David; Ansermino, J Mark; Dumont, Guy A
2013-01-01
Heart Rate Variability (HRV), the variation of time intervals between heartbeats, is one of the most promising and widely used quantitative markers of autonomic activity. Traditionally, HRV is measured as the series of instantaneous cycle intervals obtained from the electrocardiogram (ECG). In this study, we investigated the estimation of variation in heart rate from a photoplethysmography (PPG) signal, called pulse rate variability (PRV), and assessed its accuracy as an estimate of HRV in children with and without sleep disordered breathing (SDB). We recorded raw PPGs from 72 children using the Phone Oximeter, an oximeter connected to a mobile phone. Full polysomnography including ECG was simultaneously recorded for each subject. We used correlation and Bland-Altman analysis for comparing the parameters of HRV and PRV between two groups of children. Significant correlation (r > 0.90, p < 0.05) and close agreement were found between HRV and PRV for mean intervals, standard deviation of intervals (SDNN) and the root-mean square of the difference of successive intervals (RMSSD). However Bland-Altman analysis showed a large divergence for LF/HF ratio parameter. In addition, children with SDB had depressed SDNN and RMSSD and elevated LF/HF in comparison to children without SDB. In conclusion, PRV provides the accurate estimate of HRV in time domain analysis but does not reflect precise estimation for parameters in frequency domain.
Heart Rate Detection Using Microsoft Kinect: Validation and Comparison to Wearable Devices
Agostinelli, Angela; Belli, Alberto; Cippitelli, Enea; Fioretti, Sandro; Pierleoni, Paola; Ricciuti, Manola
2017-01-01
Contactless detection is one of the new frontiers of technological innovation in the field of healthcare, enabling unobtrusive measurements of biomedical parameters. Compared to conventional methods for Heart Rate (HR) detection that employ expensive and/or uncomfortable devices, such as the Electrocardiograph (ECG) or pulse oximeter, contactless HR detection offers fast and continuous monitoring of heart activities and provides support for clinical analysis without the need for the user to wear a device. This paper presents a validation study for a contactless HR estimation method exploiting RGB (Red, Green, Blue) data from a Microsoft Kinect v2 device. This method, based on Eulerian Video Magnification (EVM), Photoplethysmography (PPG) and Videoplethysmography (VPG), can achieve performance comparable to classical approaches exploiting wearable systems, under specific test conditions. The output given by a Holter, which represents the gold-standard device used in the test for ECG extraction, is considered as the ground-truth, while a comparison with a commercial smartwatch is also included. The validation process is conducted with two modalities that differ for the availability of a priori knowledge about the subjects’ normal HR. The two test modalities provide different results. In particular, the HR estimation differs from the ground-truth by 2% when the knowledge about the subject’s lifestyle and his/her HR is considered and by 3.4% if no information about the person is taken into account. PMID:28767091
A Continuous Identity Authentication Scheme Based on Physiological and Behavioral Characteristics.
Wu, Guannan; Wang, Jian; Zhang, Yongrong; Jiang, Shuai
2018-01-10
Wearable devices have flourished over the past ten years providing great advantages to people and, recently, they have also been used for identity authentication. Most of the authentication methods adopt a one-time authentication manner which cannot provide continuous certification. To address this issue, we present a two-step authentication method based on an own-built fingertip sensor device which can capture motion data (e.g., acceleration and angular velocity) and physiological data (e.g., a photoplethysmography (PPG) signal) simultaneously. When the device is worn on the user's fingertip, it will automatically recognize whether the wearer is a legitimate user or not. More specifically, multisensor data is collected and analyzed to extract representative and intensive features. Then, human activity recognition is applied as the first step to enhance the practicability of the authentication system. After correctly discriminating the motion state, a one-class machine learning algorithm is applied for identity authentication as the second step. When a user wears the device, the authentication process is carried on automatically at set intervals. Analyses were conducted using data from 40 individuals across various operational scenarios. Extensive experiments were executed to examine the effectiveness of the proposed approach, which achieved an average accuracy rate of 98.5% and an F1-score of 86.67%. Our results suggest that the proposed scheme provides a feasible and practical solution for authentication.
NASA Astrophysics Data System (ADS)
Cosoli, G.; Casacanditella, L.; Tomasini, E. P.; Scalise, L.
2016-06-01
The assessment of the heart rate variability (HRV) is of utmost importance, being one of the most promising markers of the activity of the autonomic nervous system and associated to cardiovascular mortality. Different signals can be used to perform HRV, primarily electrocardiography (ECG), photoplethysmography (PPG), phonocardiography (PCG) or vibrocardiography (VCG), since the fundamental aspect is the individuation of a periodic feature strictly correlated with cardiac activity (i.e. R-peak in ECG or the first sound in PCG). In this work, the authors demonstrate that the VCG performances in HRV analysis are sufficiently accurate if compared to the ones measured by ECG (i.e. standard methodology); moreover, the authors want to prove the feasibility of such measurement in correspondence of different measurement points (i.e. carotid artery—which is the typical VCG measurement point—and the radial artery on the wrist)1. Results show that VCG has a mean deviation of <1 bpm with respect to ECG in heart rate (HR) measurement; carotid artery is the most accurate site for the assessment, but also the radial artery is a valid site, even if with a reduced SNR. With regards to HRV parameters, the mean percentage deviation is <10% in correspondence of carotid artery, and ≈16% for the radial artery. So, VCG allows for non-contact monitoring of the cardiac activity.
Adam, Garret; Wang, Kevin; Demaree, Christopher J.; Jiang, Jenny S.; Cheung, Mathew; Bechara, Carlos F.
2018-01-01
Thoracic outlet syndrome (TOS) is a neurovascular condition involving the upper extremity, which is known to occur in individuals who perform chronic repetitive upper extremity activities. We prospectively evaluate the incidence of TOS in high-performance musicians who played bowed string musicians. Sixty-four high-performance string instrument musicians from orchestras and professional musical bands were included in the study. Fifty-two healthy volunteers formed an age-matched control group. Bilateral upper extremity duplex scanning for subclavian vessel compression was performed in all subjects. Provocative maneuvers including Elevated Arm Stress Test (EAST) and Upper Limb Tension Test (ULTT) were performed. Abnormal ultrasound finding is defined by greater than 50% subclavian vessel compression with arm abduction, diminished venous waveforms, or arterial photoplethysmography (PPG) tracing with arm abduction. Bowed string instruments performed by musicians in our study included violin (41%), viola (33%), and cello (27%). Positive EAST or ULTT test in the musician group and control group were 44%, and 3%, respectively (p = 0.03). Abnormal ultrasound scan with vascular compression was detected in 69% of musicians, in contrast to 15% of control subjects (p = 0.03). TOS is a common phenomenon among high-performance bowed string instrumentalists. Musicians who perform bowed string instruments should be aware of this condition and its associated musculoskeletal symptoms. PMID:29370085
A Continuous Identity Authentication Scheme Based on Physiological and Behavioral Characteristics
Wu, Guannan; Wang, Jian; Zhang, Yongrong; Jiang, Shuai
2018-01-01
Wearable devices have flourished over the past ten years providing great advantages to people and, recently, they have also been used for identity authentication. Most of the authentication methods adopt a one-time authentication manner which cannot provide continuous certification. To address this issue, we present a two-step authentication method based on an own-built fingertip sensor device which can capture motion data (e.g., acceleration and angular velocity) and physiological data (e.g., a photoplethysmography (PPG) signal) simultaneously. When the device is worn on the user’s fingertip, it will automatically recognize whether the wearer is a legitimate user or not. More specifically, multisensor data is collected and analyzed to extract representative and intensive features. Then, human activity recognition is applied as the first step to enhance the practicability of the authentication system. After correctly discriminating the motion state, a one-class machine learning algorithm is applied for identity authentication as the second step. When a user wears the device, the authentication process is carried on automatically at set intervals. Analyses were conducted using data from 40 individuals across various operational scenarios. Extensive experiments were executed to examine the effectiveness of the proposed approach, which achieved an average accuracy rate of 98.5% and an F1-score of 86.67%. Our results suggest that the proposed scheme provides a feasible and practical solution for authentication. PMID:29320463
Properties of Organic Matrix Short Fiber Composites
1982-02-01
reinforced SMC composites ( Owens Corning Fiberglas System) ............... ........................ ... 37 4 Schematic of process used to manufacture XMC...71 Vi F, viii. TLST OF TABLES TABLEPAE 1 Material formulations and densitius of SMC materials (PPG-PPG Industries, OFC- Owens Corning Fiberglas) (refs...Composite Materials, 14 (April 1980) , 142-154. 16 ,. Table 1. Material formulations and densities of SMC materials. (PPG-PPG Industries, OFC- Owens
Elgendi, Mohamed; Norton, Ian; Brearley, Matt; Fletcher, Richard R.; Abbott, Derek; Lovell, Nigel H.; Schuurmans, Dale
2015-01-01
Recent clinical studies show that the contour of the photoplethysmogram (PPG) wave contains valuable information for characterizing cardiovascular activity. However, analyzing the PPG wave contour is difficult; therefore, researchers have applied first or higher order derivatives to emphasize and conveniently quantify subtle changes in the filtered PPG contour. Our hypothesis is that analyzing the whole PPG recording rather than each PPG wave contour or on a beat-by-beat basis can detect heat-stressed subjects and that, consequently, we will be able to investigate the impact of global warming on human health. Here, we explore the most suitable derivative order for heat stress assessment based on the energy and entropy of the whole PPG recording. The results of our study indicate that the use of the entropy of the seventh derivative of the filtered PPG signal shows promising results in detecting heat stress using 20-second recordings, with an overall accuracy of 71.6%. Moreover, the combination of the entropy of the seventh derivative of the filtered PPG signal with the root mean square of successive differences, or RMSSD (a traditional heart rate variability index of heat stress), improved the detection of heat stress to 88.9% accuracy. PMID:26473907
An optimal filter for short photoplethysmogram signals
Liang, Yongbo; Elgendi, Mohamed; Chen, Zhencheng; Ward, Rabab
2018-01-01
A photoplethysmogram (PPG) contains a wealth of cardiovascular system information, and with the development of wearable technology, it has become the basic technique for evaluating cardiovascular health and detecting diseases. However, due to the varying environments in which wearable devices are used and, consequently, their varying susceptibility to noise interference, effective processing of PPG signals is challenging. Thus, the aim of this study was to determine the optimal filter and filter order to be used for PPG signal processing to make the systolic and diastolic waves more salient in the filtered PPG signal using the skewness quality index. Nine types of filters with 10 different orders were used to filter 219 (2.1s) short PPG signals. The signals were divided into three categories by PPG experts according to their noise levels: excellent, acceptable, or unfit. Results show that the Chebyshev II filter can improve the PPG signal quality more effectively than other types of filters and that the optimal order for the Chebyshev II filter is the 4th order. PMID:29714722
NASA Astrophysics Data System (ADS)
Manap, Siti Munirah; Ahmad, Azizan; Anuar, Farah Hannan
2016-11-01
A polyurethane films consisting of PLLA, PPG and PLLA-PPG were prepared using solution casting method. Three types of polyurethane were prepared: PPLA:PMDI, PPG:PMDI and PLLA-PPG:PMDI in the presence of polymeric diphenylmethane diisocyanate (PMDI) as the coupling agent and catalyst, Sn(Oct)2. The aim of this research was to improve the physicals properties of PLLA and PPG homopolymers through copolymerization between the two polymers. The homopolymers and polyurethane films were characterized using ATR-FTIR spectroscopy. Chemical reaction between PLLA, PPG and PMDI before and after the reaction were confirmed by observing the shifting of wavenumber for the carbonyl and ether group. Other than that, the additional band for N-H after the reaction indicated that the reaction was successful.
Orphanidou, Christina
2017-02-01
A new method for extracting the respiratory rate from ECG and PPG obtained via wearable sensors is presented. The proposed technique employs Ensemble Empirical Mode Decomposition in order to identify the respiration "mode" from the noise-corrupted Heart Rate Variability/Pulse Rate Variability and Amplitude Modulation signals extracted from ECG and PPG signals. The technique was validated with respect to a Respiratory Impedance Pneumography (RIP) signal using the mean absolute and the average relative errors for a group ambulatory hospital patients. We compared approaches using single respiration-induced modulations on the ECG and PPG signals with approaches fusing the different modulations. Additionally, we investigated whether the presence of both the simultaneously recorded ECG and PPG signals provided a benefit in the overall system performance. Our method outperformed state-of-the-art ECG- and PPG-based algorithms and gave the best results over the whole database with a mean error of 1.8bpm for 1min estimates when using the fused ECG modulations, which was a relative error of 10.3%. No statistically significant differences were found when comparing the ECG-, PPG- and ECG/PPG-based approaches, indicating that the PPG can be used as a valid alternative to the ECG for applications using wearable sensors. While the presence of both the ECG and PPG signals did not provide an improvement in the estimation error, it increased the proportion of windows for which an estimate was obtained by at least 9%, indicating that the use of two simultaneously recorded signals might be desirable in high-acuity cases where an RR estimate is required more frequently. Copyright © 2016 Elsevier Ltd. All rights reserved.
Heart Rate Monitor for Portable MP3 Player.
Kim, Jaywoo; Lee, Mi-Hee; Lee, Hyoung-Ki; Choi, Kiwan; Bang, Seokwon; Kim, Sangryong
2005-01-01
This paper presents a photoplethysmography sensor based on a heart rate monitor for a portable MP3 player. Two major design issues are addressed: one is to acquire the sensor signal with a proper amplitude despite a wide range of variation and the other is to handle the noise contaminated signal which is caused by a motion artifact. A benchmarking test with a professional medical photoplethysmography sensor shows that our device performs very well in calculating heart rate even though our photoplethysmography sensor module was designed to be cost effective.
Smartphone-based photoplethysmographic imaging for heart rate monitoring.
Alafeef, Maha
2017-07-01
The purpose of this study is to make use of visible light reflected mode photoplethysmographic (PPG) imaging for heart rate (HR) monitoring via smartphones. The system uses the built-in camera feature in mobile phones to capture video from the subject's index fingertip. The video is processed, and then the PPG signal resulting from the video stream processing is used to calculate the subject's heart rate. Records from 19 subjects were used to evaluate the system's performance. The HR values obtained by the proposed method were compared with the actual HR. The obtained results show an accuracy of 99.7% and a maximum absolute error of 0.4 beats/min where most of the absolute errors lay in the range of 0.04-0.3 beats/min. Given the encouraging results, this type of HR measurement can be adopted with great benefit, especially in the conditions of personal use or home-based care. The proposed method represents an efficient portable solution for HR accurate detection and recording.
Elgendi, Mohamed; Norton, Ian; Brearley, Matt; Fletcher, Richard R; Abbott, Derek; Lovell, Nigel H; Schuurmans, Dale
2015-10-14
Recent clinical studies show that the contour of the photoplethysmogram (PPG) wave contains valuable information for characterizing cardiovascular activity. However, analyzing the PPG wave contour is difficult; therefore, researchers have applied first or higher order derivatives to emphasize and conveniently quantify subtle changes in the filtered PPG contour. Our hypothesis is that analyzing the whole PPG recording rather than each PPG wave contour or on a beat-by-beat basis can detect heat-stressed subjects and that, consequently, we will be able to investigate the impact of global warming on human health. Here, we explore the most suitable derivative order for heat stress assessment based on the energy and entropy of the whole PPG recording. The results of our study indicate that the use Int. J. Environ. Res. Public Health 2015, 7 12777 of the entropy of the seventh derivative of the filtered PPG signal shows promising results in detecting heat stress using 20-second recordings, with an overall accuracy of 71.6%. Moreover, the combination of the entropy of the seventh derivative of the filtered PPG signal with the root mean square of successive differences, or RMSSD (a traditional heart rate variability index of heat stress), improved the detection of heat stress to 88.9% accuracy.
Alian, Aymen A; Atteya, Gourg; Gaal, Dorothy; Golembeski, Thomas; Smith, Brian G; Dai, Feng; Silverman, David G; Shelley, Kirk
2016-08-01
Scoliosis surgery is often associated with substantial blood loss, requiring fluid resuscitation and blood transfusions. In adults, dynamic preload indices have been shown to be more reliable for guiding fluid resuscitation, but these indices have not been useful in children undergoing surgery. The aim of this study was to introduce frequency-analyzed photoplethysmogram (PPG) and arterial pressure waveform variables and to study the ability of these parameters to detect early bleeding in children during surgery. We studied 20 children undergoing spinal fusion. Electrocardiogram, arterial pressure, finger pulse oximetry (finger PPG), and airway pressure waveforms were analyzed using time domain and frequency domain methods of analysis. Frequency domain analysis consisted of calculating the amplitude density of PPG and arterial pressure waveforms at the respiratory and cardiac frequencies using Fourier analysis. This generated 2 measurements: The first is related to slow mean arterial pressure modulation induced by ventilation (also known as DC modulation when referring to the PPG), and the second corresponds to pulse pressure modulation (AC modulation or changes in the amplitude of pulse oximeter plethysmograph when referring to the PPG). Both PPG and arterial pressure measurements were divided by their respective cardiac pulse amplitude to generate DC% and AC% (normalized values). Standard hemodynamic data were also recorded. Data at baseline and after bleeding (estimated blood loss about 9% of blood volume) were presented as median and interquartile range and compared using Wilcoxon signed-rank tests; a Bonferroni-corrected P value <0.05 was considered statistically significant. There were significant increases in PPG DC% (median [interquartile range] = 359% [210 to 541], P = 0.002), PPG AC% (160% [87 to 251], P = 0.003), and arterial DC% (44% [19 to 84], P = 0.012) modulations, respectively, whereas arterial AC% modulations showed nonsignificant increase (41% [1 to 85], P = 0.12). The change in PPG DC% was significantly higher than that in PPG AC%, arterial DC%, arterial AC%, and systolic blood pressure with P values of 0.008, 0.002, 0.003, and 0.002, respectively. Only systolic blood pressure showed significant changes (11% [4 to 21], P = 0.003) between bleeding phase and baseline. Finger PPG and arterial waveform parameters (using frequency analysis) can track changes in blood volume during the bleeding phase, suggesting the potential for a noninvasive monitor for tracking changes in blood volume in pediatric patients. PPG waveform baseline modulation (PPG DC%) was more sensitive to changes in venous blood volume when compared with respiration-induced modulation seen in the arterial pressure waveform.
Su, Jian-Bin; Yang, Xiao-Hua; Zhang, Xiu-Lin; Cai, Hong-Li; Huang, Hai-Yan; Zhao, Li-Hua; Xu, Feng; Chen, Tong; Cheng, Xing-Bo; Wang, Xue-Qin; Lu, Yan
2017-01-01
Prolonged heart rate-corrected QT(QTc) interval is related to ventricular arrhythmia and cardiovascular mortality, with considerably high prevalence of type 2 diabetes. Additionally, long-term glycaemic variability could be a significant risk factor for diabetic complications in addition to chronic hyperglycaemia. We compared the associations of long-term glycaemic variability versus sustained chronic hyperglycaemia with the QTc interval among type 2 diabetes patients. In this cross-sectional study, 2904 type 2 diabetes patients were recruited who had undergone at least four fasting plasma glucose (FPG) and 2-hour postprandial plasma glucose (PPG) measurements (at least once for every 3 months, respectively) during the preceding year. Long-term glycaemic variabilities of FPG and 2-hour PPG were assessed by their standard deviations (SD-FPG and SD-PPG, respectively), and chronic fasting and postprandial hyperglycaemia were assessed by their means (M-FPG and M-PPG, respectively). HbA1c was also determined upon enrolment to assess current overall glycaemic control. QTc interval was estimated from resting 12-lead electrocardiograms, and more than 440 ms was considered abnormally prolonged. Patients with prolonged QTc interval (≥440 ms) had greater M-FPG, M-PPG, SD-PPG and HbA1c than those with normal QTc interval but comparable SD-FPG. QTc interval was correlated with M-FPG, M-PPG, SD-PPG and HbA1c (r = 0.133, 0.153, 0.245 and 0.207, respectively, p = 0.000) but not with SD-FPG (r = 0.024, p = 0.189). After adjusting for metabolic risk factors via multiple linear regression analysis, SD-PPG, M-PPG and HbA1c (t = 12.16, 2.69 and 10.16, respectively, p = 0.000) were the major independent contributors to the increased QTc interval. The proportion of prolonged QTc interval increased significantly from 10.9% to 14.2% to 26.6% for the first (T1) to second (T2) to third (T3) tertiles of SD-PPG. After adjusting via multiple logistic regression analysis, the odd ratios of prolonged QTc interval of the T2 and T3 versus the T1 of SD-PPG were 1.15 (95% CI, 0.82-1.60) and 2.62 (1.92-3.57), respectively. Increased long-term variability of PPG is a strong independent risk factor for prolonged QTc interval in type 2 diabetes patients, in addition to long-term postprandial hyperglycaemia and current HbA1c.
Martins, Andréa Bercini; Santana, Ruth Marlene Campomanes
2016-01-01
In this work, polypropylene/thermoplastic starch (PP/TPS) blends were prepared as an alternative material to use in disposable packaging, reducing the negative polymeric environmental impact. Unfortunately, this material displays morphological characteristics typical of immiscible polymer blends and a compatibilizer agent is needed. Three different carboxyl acids: myristic (C14), palmitic (C16) and stearic acids (C18) were used as natural compatibilizer agent (NCA). The effects of NCA on the mechanical, physical, thermal and morphological properties of PP/TPS blends were investigated and compared against PP/TPS with and without PP-grafted maleic anhydride (PPgMA). When compared to PP/TPS, blends with C18, PPgMA and C14 presented an improvement of 25, 22 and 17% in tensile strength at break and of 180, 194 and 259% in elongation at break, respectively. The highest increase, 54%, in the impact strength was achieved with C14 incorporation. Improvements could be seen, through scanning electron microscopy (SEM) images, in the compatibility between the immiscible components by acids incorporation. These results showed that carboxylic acids, specifically C14, could be used as compatibilizer agent and could substitute PPgMA. Copyright © 2015 Elsevier Ltd. All rights reserved.
Fortgang, Rebecca G; Hoff, Rani A; Potenza, Marc N
2018-02-16
High rates of both problem and pathological gambling (PPG) and substance-use disorders (SUDs) have been reported in schizophrenia, and yet PPG frequently goes undetected in clinical practice and unexamined in research. Here, we aimed to examine the relationship between PPG and SUDs in a large sample of patients across several factors related to both gambling and substance use, including poly-substance use. Additionally, delay discounting is a form of impulsivity known to positively associate with both PPG and SUDs and thought to underlie mechanisms of addiction in both contexts. We aimed to investigate the relationship between PPG and delay discounting in schizophrenia. 337 individuals with schizophrenia completed structured face-to-face interviews regarding gambling behaviors, substance use, and delay discounting. PPG in schizophrenia was associated with substance use, in particular with poly-substance use, and with delay discounting among males. Factors related to substance use were strongly linked with gambling in this sample, but not always with PPG more than recreational gambling. Our findings overall support the notions that multiple forms of gambling in schizophrenia are clinically relevant, that gambling may share common substrates with substance use, and that delay discounting represents a potential mechanism of this association in males.
Dual channel photoplethysmography studies of cardio-vascular response to the body position changes
NASA Astrophysics Data System (ADS)
Erts, R.; Kukulis, I.; Spigulis, J.; Kere, L.
2005-08-01
The dual-channel photoplethysmography studies of physiological responses during 3-stage orthostatic test were performed. Clear differences in heartbeat rate, pulse wave transit time and blood pressure variations of healthy volunteers and diabetic patients have been observed.
PPG neurons of the lower brain stem and their role in brain GLP-1 receptor activation
Cork, Simon C.
2015-01-01
Within the brain, glucagon-like peptide-1 (GLP-1) affects central autonomic neurons, including those controlling the cardiovascular system, thermogenesis, and energy balance. Additionally, GLP-1 influences the mesolimbic reward system to modulate the rewarding properties of palatable food. GLP-1 is produced in the gut and by hindbrain preproglucagon (PPG) neurons, located mainly in the nucleus tractus solitarii (NTS) and medullary intermediate reticular nucleus. Transgenic mice expressing glucagon promoter-driven yellow fluorescent protein revealed that PPG neurons not only project to central autonomic control regions and mesolimbic reward centers, but also strongly innervate spinal autonomic neurons. Therefore, these brain stem PPG neurons could directly modulate sympathetic outflow through their spinal inputs to sympathetic preganglionic neurons. Electrical recordings from PPG neurons in vitro have revealed that they receive synaptic inputs from vagal afferents entering via the solitary tract. Vagal afferents convey satiation to the brain from signals like postprandial gastric distention or activation of peripheral GLP-1 receptors. CCK and leptin, short- and long-term satiety peptides, respectively, increased the electrical activity of PPG neurons, while ghrelin, an orexigenic peptide, had no effect. These findings indicate that satiation is a main driver of PPG neuronal activation. They also show that PPG neurons are in a prime position to respond to both immediate and long-term indicators of energy and feeding status, enabling regulation of both energy balance and general autonomic homeostasis. This review discusses the question of whether PPG neurons, rather than gut-derived GLP-1, are providing the physiological substrate for the effects elicited by central nervous system GLP-1 receptor activation. PMID:26290108
PPG neurons of the lower brain stem and their role in brain GLP-1 receptor activation.
Trapp, Stefan; Cork, Simon C
2015-10-15
Within the brain, glucagon-like peptide-1 (GLP-1) affects central autonomic neurons, including those controlling the cardiovascular system, thermogenesis, and energy balance. Additionally, GLP-1 influences the mesolimbic reward system to modulate the rewarding properties of palatable food. GLP-1 is produced in the gut and by hindbrain preproglucagon (PPG) neurons, located mainly in the nucleus tractus solitarii (NTS) and medullary intermediate reticular nucleus. Transgenic mice expressing glucagon promoter-driven yellow fluorescent protein revealed that PPG neurons not only project to central autonomic control regions and mesolimbic reward centers, but also strongly innervate spinal autonomic neurons. Therefore, these brain stem PPG neurons could directly modulate sympathetic outflow through their spinal inputs to sympathetic preganglionic neurons. Electrical recordings from PPG neurons in vitro have revealed that they receive synaptic inputs from vagal afferents entering via the solitary tract. Vagal afferents convey satiation to the brain from signals like postprandial gastric distention or activation of peripheral GLP-1 receptors. CCK and leptin, short- and long-term satiety peptides, respectively, increased the electrical activity of PPG neurons, while ghrelin, an orexigenic peptide, had no effect. These findings indicate that satiation is a main driver of PPG neuronal activation. They also show that PPG neurons are in a prime position to respond to both immediate and long-term indicators of energy and feeding status, enabling regulation of both energy balance and general autonomic homeostasis. This review discusses the question of whether PPG neurons, rather than gut-derived GLP-1, are providing the physiological substrate for the effects elicited by central nervous system GLP-1 receptor activation. Copyright © 2015 the American Physiological Society.
Kim, Hae Jin; Song, Yong Ju; Kim, Young Kook; Jeoung, Jin Wook; Park, Ki Ho
2017-07-01
To evaluate functional progression in preperimetric glaucoma (PPG) with disc hemorrhage (DH) and to determine the time interval between the first-detected DH and development of glaucomatous visual field (VF) defect. A total of 87 patients who had been first diagnosed with PPG were enrolled. The medical records of PPG patients without DH (Group 1) and with DH (Group 2) were reviewed. When glaucomatous VF defect appeared, the time interval from the diagnosis of PPG to the development of VF defect was calculated and compared between the two groups. In group 2, the time intervals from the first-detected DH to VF defect of the single- and recurrent-DH were compared. Of the enrolled patients, 45 had DH in the preperimetric stage. The median time interval from the diagnosis of PPG to the development of VF defect was 73.3 months in Group 1, versus 45.4 months in Group 2 (P = 0.042). The cumulative probability of development of VF defect after diagnosis of PPG was significantly greater in Group 2 than in Group 1. The median time interval from first-detected DH to the development of VF defect was 37.8 months. The median time interval from DH to VF defect and cumulative probability of VF defect after DH did not show a statistical difference between single and recurrent-DH patients. The median time interval between the diagnosis of PPG and the development of VF defect was significantly shorter in PPG with DH. The VF defect appeared 37.8 months after the first-detected DH in PPG.
One Bout of Exercise Alters Free-Living Postprandial Glycemia in Type 2 Diabetes
Oberlin, Douglas J.; Mikus, Catherine R.; Kearney, Monica L.; Hinton, Pamela S.; Manrique, Camila; Leidy, Heather J.; Kanaley, Jill A.; Rector, R. Scott; Thyfault, John P.
2015-01-01
PURPOSE Elevated postprandial glycemic excursions (PPG) are significant risk factors for cardiovascular disease in type 2 diabetes patients. Here we tested if and for how many meals a single bout of exercise would reduce PPG responses to subsequent meals in type 2 diabetes (T2D) patients using continuous glucose monitors (CGMS). METHODS We recruited 9 sedentary (<30 minutes/week of exercise) individuals with T2D (BMI: 36.0 ± 1.1 kg/m2; age 60.3 ± 1.0 years; HbA1c: 6.3 ± 0.2 %). The subjects consumed a eucaloric diet (51% carbohydrate, 31% fat, 18% protein) consisting of 3 meals, identical in composition, over a 2-day period while wearing CGMS in two different conditions (exercise (EX; one 60 minute bout at 60-75% of heart rate reserve performed prior to breakfast) vs. a sedentary (SED) condition). We quantified 24-h average glucose, PPG-AUC (4 h glucose AUC following meals) and PPG-2 h (2 hour post-prandial glucose). RESULTS EX significantly reduced average [glucose] during the first 24 hour period (p=0.03). EX caused a reduction in PPG-AUC (p=0.02) for all of the meals over the two days (main effect between conditions). Comparison between the EX and SED conditions at each meal revealed that EX reduced PPG-AUC following the second meal of day 1 (lunch) (p=0.04). PPG-2 h was not significantly different between EX and SED. CONCLUSION Although a single EX bout does lower 24-h average [glucose], it only significantly lowered PPG-AUC at the second meal following the bout suggesting that daily exercise may be needed to most effectively improve PPG at the advent of exercise training in T2D patients. PMID:23872939
Pöggeler, S
2000-06-01
In order to analyze the involvement of pheromones in cell recognition and mating in a homothallic fungus, two putative pheromone precursor genes, named ppg1 and ppg2, were isolated from a genomic library of Sordaria macrospora. The ppg1 gene is predicted to encode a precursor pheromone that is processed by a Kex2-like protease to yield a pheromone that is structurally similar to the alpha-factor of the yeast Saccharomyces cerevisiae. The ppg2 gene encodes a 24-amino-acid polypeptide that contains a putative farnesylated and carboxy methylated C-terminal cysteine residue. The sequences of the predicted pheromones display strong structural similarity to those encoded by putative pheromones of heterothallic filamentous ascomycetes. Both genes are expressed during the life cycle of S. macrospora. This is the first description of pheromone precursor genes encoded by a homothallic fungus. Southern-hybridization experiments indicated that ppg1 and ppg2 homologues are also present in other homothallic ascomycetes.
Shimizu, Hiroyuki; Uehara, Yutaka; Okada, Shuichi; Mori, Masatomo
2008-08-01
The contribution of fasting and postprandial glucose to hemoglobin A(1c) (HbA(1c)) levels was evaluated in insulin-treated patients. In 57 insulin-treated, diabetic out-patients, fasting glucose (before breakfast (B-FG), lunch (L-FG) and dinner (D-FG)) and postprandial glucose (B-PPG, L-PPG and D-PPG) levels were determined by the patients themselves at home using glucose self-monitoring apparatus over the course of one week. The correlation between HbA(1c) levels and self monitored blood glucose levels were calculated. In the conventionally treated group, there was a significant correlation between HbA(1c) and fasting glucose (FG) levels only before lunch, but at 2 hr after (PPG) all meals. In the intensively treated group, a significant correlation between HbA(1c) levels and FG levels was found before lunch and at 2 hr after breakfast and dinner. In all subjects, only FG levels before lunch correlated significantly with HbA(1c) levels, although PPG levels were significantly correlated with HbA(1c) at all points. The correlation was highest with PPG after breakfast and dinner. The sum of all FG, PPG and FG + PPG levels was significantly correlated with HbA(1c) levels. Postprandial hyperglycemia after breakfast and dinner should be regarded as most important for improving HbA(1c) levels in insulin treated diabetic patients.
Preparation of Polyamide-6 Submicrometer-Sized Spheres by In Situ Polymerization.
Zhao, Xingke; Xia, Housheng; Fu, Xubing; Duan, Jianping; Yang, Guisheng
2015-11-01
Polyamide-6 (PA6) submicron-sized spheres are prepared by two steps: (1) anionic ring-opening polymerization of ε-caprolactam in the presence of poly(ethylene glycol)-block-poly-(propylene glycol)-block-poly(ethylene glycol)(PEG-b-PPG-b-PEG) and (2) separation of PA6 spheres by dissolving PEG-b-PPG-b-PEG from the prepared blends. The PA6 microspheres obtained are regular spherical, with diameter ranging from 200 nm to 2 μm and narrow size distribution, as confirmed by scanning electron microscopy. By comparison with PA6/PS and PA6/PEG systems, it is denominated that the PEG blocks in PEG-b-PPG-b-PEG can effectively reduce the surface tension of PA6 droplets and further decrease the diameter of the PA6 microspheres. The PPG block in PEG-b-PPG-b-PEG can prevent the PA6 droplets coalescing with each other, and isolated spherical particles can be obtained finally. The phase inversion of the PA6/PEG-b-PPG-b-PEG blends occurs at very low PEG-b-PPG-b-PEG content; the PEG-b-PPG-b-PEG phase can be removed by water easily. The whole experiment can be finished in a short time (approximately in half an hour) without using any organic solvents; it is an efficient strategy for the preparation of submicron-sized PA6 microspheres. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Motion-compensated detection of heart rate based on the time registration adaptive filter
NASA Astrophysics Data System (ADS)
Yang, Lei; Zhou, Jinsong; Jing, Juanjuan; Li, Yacan; Wei, Lidong; Feng, Lei; He, Xiaoying; Bu, Meixia; Fu, Xilu
2018-01-01
A non-contact heart rate detection method based on the dual-wavelength technique is proposed and demonstrated experimentally. The heart rate is obtained based on the PhotoPlethysmoGraphy (PPG). Each detection module uses the reflection detection probe which is composed of the LED and the photodiode. It is a well-known fact that the differences in the circuits of two detection modules result in different responses of two modules for motion artifacts. It will cause a time delay between the two signals. This poses a great challenge to compensate the motion artifacts during measurements. In order to solve this problem, we have firstly used the time registration and translated the signals to ensure that the two signals are consistent in time domain. Then the adaptive filter is used to compensate the motion artifacts. Moreover, the data obtained by using this non-contact detection system is compared with those of the conventional finger blood volume pulse (BVP) sensor by simultaneously measuring the heart rate of the subject. During the experiment, the left hand remains stationary and is detected by a conventional finger BVP sensor. Meanwhile, the moving palm of right hand is detected by the proposed system. The data obtained from the proposed non-contact system are consistent and comparable with that of the BVP sensor. This method can effectively suppress the interference caused by the two circuit differences and successfully compensate the motion artifacts. This technology can be used in medical and daily heart rate measurement.
Comparison of Glaucoma Progression Detection by Optical Coherence Tomography and Visual Field.
Zhang, Xinbo; Dastiridou, Anna; Francis, Brian A; Tan, Ou; Varma, Rohit; Greenfield, David S; Schuman, Joel S; Huang, David
2017-12-01
To compare longitudinal glaucoma progression detection using optical coherence tomography (OCT) and visual field (VF). Validity assessment. We analyzed subjects with more than 4 semi-annual follow-up visits (every 6 months) in the multicenter Advanced Imaging for Glaucoma Study. Fourier-domain optical coherence tomography (OCT) was used to map the thickness of the peripapillary retinal nerve fiber layer (NFL) and ganglion cell complex (GCC). OCT-based progression detection was defined as a significant negative trend for either NFL or GCC. VF progression was reached if either the event or trend analysis reached significance. The analysis included 356 glaucoma suspect/preperimetric glaucoma (GS/PPG) eyes and 153 perimetric glaucoma (PG) eyes. Follow-up length was 54.1 ± 16.2 months for GS/PPG eyes and 56.7 ± 16.0 for PG eyes. Progression was detected in 62.1% of PG eyes and 59.8% of GS/PPG eyes by OCT, significantly (P < .001) more than the detection rate of 41.8% and 27.3% by VF. In severity-stratified analysis of PG eyes, OCT had significantly higher detection rate than VF in mild PG (63.1% vs. 38.7%, P < .001), but not in moderate and advanced PG. The rate of NFL thinning slowed dramatically in advanced PG, but GCC thinning rate remained relatively steady and allowed good progression detection even in advanced disease. The Kaplan-Meier time-to-event analyses showed that OCT detected progression earlier than VF in both PG and GS/PPG groups. OCT is more sensitive than VF for the detection of progression in early glaucoma. While the utility of NFL declines in advanced glaucoma, GCC remains a sensitive progression detector from early to advanced stages. Copyright © 2017 Elsevier Inc. All rights reserved.
The Analysis of PPG Morphology: Investigating the Effects of Aging on Arterial Compliance
NASA Astrophysics Data System (ADS)
Yousef, Q.; Reaz, M. B. I.; Ali, M. A. M.
2012-12-01
This study presents the variations of photoplethysmogram (PPG) morphology with age. PPG measurement is done noninvasively at the index finger on both right and left hands for a sample of erectile dysfunction (ED) subjects. Some parameters are derived from the analysis of PPG contour showed in association with age. The age is found to be an important factor that affects the contour of PPG signals which accelerates the disappearance of PPG’s dicrotic notch and PPG’s inflection point as well. Arterial compliance is found to be degraded with age due to the fall of arterial elasticity. This study approaches the establishment of usefulness of PPG’s contour analysis as an investigator to the changes in the elastic properties of the vascular system, and as a detector of early sub-clinical atherosclerosis.
West, Robert J; Davis, John W; Pottenger, Lynn H; Banton, Marcy I; Graham, Cynthia
2007-05-01
Eight propylene glycol substances, ranging from 1,2-propanediol to a poly(propylene glycol) (PPG) having number-average molecular weight (M(n)) of 2,700 (i.e., PPG 2700), were evaluated in the Organization for Economic Cooperation and Development (OECD) ready- and seawater biodegradability tests. Uniformity in test parameters, such as inoculum source/density and test substance concentrations, combined with frequent measurements of O2 consumption and CO2 evolution, revealed unexpected biodegradability trends across this family of substances. Biodegradability in both tests decreased with increased number of oxy-propylene repeating units (n = 1, 2, 3, 4) of the oligomeric propylene glycols (PGs). However, this trend was reversed for the PPG polymers, and increased biodegradability was observed with increases of average n to seven, 17, and 34 (M(n) = 425, 1,000, and 2,000, respectively). This relationship between molecular weight and biodegradability was reversed again when average n was incremented from 34 (PPG 2000) to 46 (PPG 2700). Six of the tested substances (n = 1, 2, 3, 7, 17, and 34) met the OECD-specified criteria for "ready biodegradability," whereas the tetrapropylene glycol (n = 4) and PPG 2700 substances failed to meet these criteria. Biodegradation half-lives for these eight substances ranged from 3.8 d (PPG 2000) to 33.2 d (PPG 2700) in the ready test, and from 13.6 (PG) to 410 d (PPG 2700) in seawater. Biodegradation half-lives in seawater were significantly correlated with half-lives determined in the ready test. However, half-lives in both tests were correlated poorly with molecular weight, water solubility, and log K(ow). It is speculated that the molecular conformation of these substances, perhaps more so than these other physicochemical properties, has an important role in influencing biodegradability of the propylene glycol substances.
Wireless photoplethysmographic device for heart rate variability signal acquisition and analysis.
Reyes, Ivan; Nazeran, Homer; Franco, Mario; Haltiwanger, Emily
2012-01-01
The photoplethysmographic (PPG) signal has the potential to aid in the acquisition and analysis of heart rate variability (HRV) signal: a non-invasive quantitative marker of the autonomic nervous system that could be used to assess cardiac health and other physiologic conditions. A low-power wireless PPG device was custom-developed to monitor, acquire and analyze the arterial pulse in the finger. The system consisted of an optical sensor to detect arterial pulse as variations in reflected light intensity, signal conditioning circuitry to process the reflected light signal, a microcontroller to control PPG signal acquisition, digitization and wireless transmission, a receiver to collect the transmitted digital data and convert them back to their analog representations. A personal computer was used to further process the captured PPG signals and display them. A MATLAB program was then developed to capture the PPG data, detect the RR peaks, perform spectral analysis of the PPG data, and extract the HRV signal. A user-friendly graphical user interface (GUI) was developed in LabView to display the PPG data and their spectra. The performance of each module (sensing unit, signal conditioning, wireless transmission/reception units, and graphical user interface) was assessed individually and the device was then tested as a whole. Consequently, PPG data were obtained from five healthy individuals to test the utility of the wireless system. The device was able to reliably acquire the PPG signals from the volunteers. To validate the accuracy of the MATLAB codes, RR peak information from each subject was fed into Kubios software as a text file. Kubios was able to generate a report sheet with the time domain and frequency domain parameters of the acquired data. These features were then compared against those calculated by MATLAB. The preliminary results demonstrate that the prototype wireless device could be used to perform HRV signal acquisition and analysis.
Roman-Gonzalez, Alejandro; Zhou, Shouhao; Ayala-Ramirez, Montserrat; Shen, Chan; Waguespack, Steven G; Habra, Mouhammed A; Karam, Jose A; Perrier, Nancy; Wood, Christopher G; Jimenez, Camilo
2018-07-01
To determine whether primary tumor resection in patients with metastatic pheochromocytoma or paraganglioma (PPG) is associated with longer overall survival (OS). Patients with metastatic PPG have poor survival outcomes. The impact of surgical resection of the primary tumor on OS is not known. We retrospectively studied patients with metastatic PPG treated at the University of Texas, MD Anderson Cancer Center from January 2000 through January 2015. Kaplan-Meier analysis with log-rank tests was used to compare OS among patients undergoing primary tumor resection and patients not treated surgically. Propensity score method was applied to adjust for selection bias using demographic, clinical, biochemical, genetic, imaging, and pathologic information. A total of 113 patients with metastatic PPG were identified. Eighty-nine (79%) patients had surgery and 24 (21%) patients did not. Median OS was longer in patients who had surgery than in patients who did not [148 months, 95% confidence interval (CI) 112.8-183.2 months vs 36 months, 95% CI 27.2-44.8 months; P < 0.001].Fifty-three (46%) patients had synchronous metastases; of these patients, those who had surgery had longer OS than those who did not (85 months, 95% CI 64.5-105.4 months vs 36 months, 95% CI 29.7-42.3 months; P < 0.001). Patients who had surgery had a similar ECOG performance status to the ones who did not (P = 0.1798, two sample t test; P = 0.2449, Wilcoxon rank sum test). Univariate and propensity score analysis confirmed that patients treated with surgery had longer OS than those not treated surgically irrespective of age, race, primary tumor size and location, number of metastatic sites, and genetic background (log-rank P < 0.001).In patients with hormonally active tumors (70.8%), the symptoms of catecholamine excess improved after surgery. However, the tumor burden was a more important determinant of OS than hormonal secretion. Primary tumor resection in patients with metastatic PPG appeared to be associated with improved OS. In patients with hormonally active tumors, surgical resection led to better blood pressure control.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-07
... does not include any sensitive personal information, like anyone's Social Security number, date of... the agreement or make final the agreement's proposed order. This matter involves PPG's marketing and... prevent PPG from engaging in similar acts and practices in the future. Part I addresses the marketing of...
Risk factors for peristomal pyoderma gangrenosum complicating inflammatory bowel disease.
Wu, Xian-rui; Mukewar, Saurabh; Kiran, Ravi P; Remzi, Feza H; Hammel, Jeffery; Shen, Bo
2013-06-01
Risk factors for peristomal pyoderma gangrenosum (PPG) are not well defined. The aim of this study was to evaluate risk factors associated with development of PPG. Both PPG patients and controls were obtained by searching a database of the Cleveland Clinic using the ICD-9 code from March 2005 to May 2011. The control group was selected by matching for underlying diseases and type of stoma in a ratio of 3:1. Univariate and multivariate analyses were performed. A total of 15 PPG cases and 45 controls were included. The mean age at the time of PPG diagnosis was 46.0 ± 14.4 years. The underlying disease was Crohn's disease in 7 patients (46.7%), ulcerative colitis in 7 (46.7%) and indeterminate colitis in 1 (6.7%). Eleven patients (73.3%) had end ileostomy, 3 (20.0%) had loop ileostomy and 1 (6.7%) had colostomy. Eleven patients (73.3%) had active intestinal disease. In multivariate analysis, female gender, the presence of concurrent autoimmune disorders, and a high body mass index (BMI) were significantly associated with the presence of PPG, with odds ratios of 8.385 (95% confidence interval [CI]: 1.496-46.982, p=0.015), 6.882 (95% CI:1.438-32.941, p=0.016), and 9.895 (95% CI: 1.970-43.704, p=0.005), respectively. After a median follow-up of 12.8 (interquartile range: 7.9-20.1) months with appropriate therapy, PPG healed in 8 patients (53.3%) and improved in 7 (46.7%) patients, after treatment. Female gender, the presence of autoimmune disorders and a high BMI appeared to be associated with an increased risk for the development of PPG in IBD patients. Copyright © 2012 European Crohn's and Colitis Organisation. Published by Elsevier B.V. All rights reserved.
Pittara, Melpo; Theocharides, Theocharis; Orphanidou, Christina
2017-07-01
A new method for deriving pulse rate from PPG obtained from ambulatory patients is presented. The method employs Ensemble Empirical Mode Decomposition to identify the pulsatile component from noise-corrupted PPG, and then uses a set of physiologically-relevant rules followed by adaptive thresholding, in order to estimate the pulse rate in the presence of noise. The method was optimized and validated using 63 hours of data obtained from ambulatory hospital patients. The F1 score obtained with respect to expertly annotated data was 0.857 and the mean absolute errors of estimated pulse rates with respect to heart rates obtained from ECG collected in parallel were 1.72 bpm for "good" quality PPG and 4.49 bpm for "bad" quality PPG. Both errors are within the clinically acceptable margin-of-error for pulse rate/heart rate measurements, showing the promise of the proposed approach for inclusion in next generation wearable sensors.
Houtman, S; Thielen, J J; Binkhorst, R A; Hopman, M T
1999-01-01
The aim of this study was to examine effects of a pulsating pressure anti-gravity suit on the peak values of oxygen uptake (VO2) and power during maximal arm exercise in spinal-cord-injured (SCI) individuals. Five well-trained SCI men (with lesions at levels between T6 and L1) and seven well-trained able-bodied men (ABC) performed two incremental (10 W x min(-1)) arm-cranking tests. During one test the pressure in the anti-G suit pulsated between 4.7 kPa (35 mmHg) and 9.3 kPa (70 mmHg) every 2 s (PPG+), during the other test (PPG-) all the subjects wore the anti-G suit in a deflated state. Tests were performed in a counter-balanced order. Peak VO2 in SCI was 1 ml x kg(-1) x min(-1) lower during PPG+ compared to PPG- (P = 0.05). Peak power and peak heart rate were not significantly different during PPG+ compared to PPG-. These results would suggest that no increase in work capacity can be obtained with a pulsating pressure anti-gravity suit in either SCI or ABC.
NASA Astrophysics Data System (ADS)
Lee, Jun Hyup; Lee, Byungsun; Son, Intae; Kim, Jae Hong; Kim, Chunho; Yoo, Ji Yong; Wu, Jong-Pyo; Kim, Younguk
2015-11-01
We have studied amphiphilic triblock copolymers poly(ethylene glycol)- b-poly(propylene glycol)- b-poly(ethylene glycol) (PEG- b-PPG- b-PEG) and poly(propylene glycol)- b-poly(ethylene glycol)- b-poly(propylene glycol) (PPG- b-PEG- b-PPG) as possible substitutes for sodium dodecyl sulfate as anionic surfactants for the removal of hydrophobic contaminants. The triblock copolymers were compared with sodium dodecyl sulfate in terms of their abilities to remove toluene as hydrophobic contaminant in fuel, and the effects of polymer structure, PEG content, and concentration were studied. The PEG- b-PPG- b-PEG copolymer containing two hydrophilic PEG blocks was more effective for the removal of hydrophobic contaminant at extremely high concentration. We also measured the removal capabilities of the triblock copolymers having various PEG contents and confirmed that removal capability was greatest at 10% PEG content regardless of polymer structure. As with sodium dodecyl sulfate, the removal efficiency of a copolymer has a positive correlation with its concentration. Finally, we proposed the amphiphilic triblock copolymer of PPG- b-PEG- b-PPG bearing 10% PEG content that proved to be the most effective substitute for sodium dodecyl sulfate.
Song, Jiajia; Li, Dan; Ma, Xiaoyuan; Teng, Guowei; Wei, Jianming
2017-01-01
Dynamic accurate heart-rate (HR) estimation using a photoplethysmogram (PPG) during intense physical activities is always challenging due to corruption by motion artifacts (MAs). It is difficult to reconstruct a clean signal and extract HR from contaminated PPG. This paper proposes a robust HR-estimation algorithm framework that uses one-channel PPG and tri-axis acceleration data to reconstruct the PPG and calculate the HR based on features of the PPG and spectral analysis. Firstly, the signal is judged by the presence of MAs. Then, the spectral peaks corresponding to acceleration data are filtered from the periodogram of the PPG when MAs exist. Different signal-processing methods are applied based on the amount of remaining PPG spectral peaks. The main MA-removal algorithm (NFEEMD) includes the repeated single-notch filter and ensemble empirical mode decomposition. Finally, HR calibration is designed to ensure the accuracy of HR tracking. The NFEEMD algorithm was performed on the 23 datasets from the 2015 IEEE Signal Processing Cup Database. The average estimation errors were 1.12 BPM (12 training datasets), 2.63 BPM (10 testing datasets) and 1.87 BPM (all 23 datasets), respectively. The Pearson correlation was 0.992. The experiment results illustrate that the proposed algorithm is not only suitable for HR estimation during continuous activities, like slow running (13 training datasets), but also for intense physical activities with acceleration, like arm exercise (10 testing datasets). PMID:29068403
Acute activation of GLP-1-expressing neurons promotes glucose homeostasis and insulin sensitivity.
Shi, Xuemei; Chacko, Shaji; Li, Feng; Li, Depei; Burrin, Douglas; Chan, Lawrence; Guan, Xinfu
2017-11-01
Glucagon-like peptides are co-released from enteroendocrine L cells in the gut and preproglucagon (PPG) neurons in the brainstem. PPG-derived GLP-1/2 are probably key neuroendocrine signals for the control of energy balance and glucose homeostasis. The objective of this study was to determine whether activation of PPG neurons per se modulates glucose homeostasis and insulin sensitivity in vivo. We generated glucagon (Gcg) promoter-driven Cre transgenic mice and injected excitatory hM3Dq-mCherry AAV into their brainstem NTS. We characterized the metabolic impact of PPG neuron activation on glucose homeostasis and insulin sensitivity using stable isotopic tracers coupled with hyperinsulinemic euglycemic clamp. We showed that after ip injection of clozapine N-oxide, Gcg-Cre lean mice transduced with hM3Dq in the brainstem NTS downregulated basal endogenous glucose production and enhanced glucose tolerance following ip glucose tolerance test. Moreover, acute activation of PPG neurons NTS enhanced whole-body insulin sensitivity as indicated by increased glucose infusion rate as well as augmented insulin-suppression of endogenous glucose production and gluconeogenesis. In contrast, insulin-stimulation of glucose disposal was not altered significantly. We conclude that acute activation of PPG neurons in the brainstem reduces basal glucose production, enhances intraperitoneal glucose tolerance, and augments hepatic insulin sensitivity, suggesting an important physiological role of PPG neurons-mediated circuitry in promoting glycemic control and insulin sensitivity. Copyright © 2017 The Authors. Published by Elsevier GmbH.. All rights reserved.
Kim, Hyungseup; Park, Yunjong; Ko, Youngwoon; Mun, Yeongjin; Lee, Sangmin; Ko, Hyoungho
2018-01-01
Wearable healthcare systems require measurements from electrocardiograms (ECGs) and photoplethysmograms (PPGs), and the blood pressure of the user. The pulse transit time (PTT) can be calculated by measuring the ECG and PPG simultaneously. Continuous-time blood pressure without using an air cuff can be estimated by using the PTT. This paper presents a biosignal acquisition integrated circuit (IC) that can simultaneously measure the ECG and PPG for wearable healthcare applications. Included in this biosignal acquisition circuit are a voltage mode instrumentation amplifier (IA) for ECG acquisition and a current mode transimpedance amplifier for PPG acquisition. The analog outputs from the ECG and PPG channels are muxed and converted to digital signals using 12-bit successive approximation register (SAR) analog-to-digital converter (ADC). The proposed IC is fabricated by using a standard 0.18 μm CMOS process with an active area of 14.44 mm2. The total current consumption for the multichannel IC is 327 μA with a 3.3 V supply. The measured input referred noise of ECG readout channel is 1.3 μVRMS with a bandwidth of 0.5 Hz to 100 Hz. And the measured input referred current noise of the PPG readout channel is 0.122 nA/√Hz with a bandwidth of 0.5 Hz to 100 Hz. The proposed IC, which is implemented using various circuit techniques, can measure ECG and PPG signals simultaneously to calculate the PTT for wearable healthcare applications.
Accuracy of smartphone apps for heart rate measurement.
Coppetti, Thomas; Brauchlin, Andreas; Müggler, Simon; Attinger-Toller, Adrian; Templin, Christian; Schönrath, Felix; Hellermann, Jens; Lüscher, Thomas F; Biaggi, Patric; Wyss, Christophe A
2017-08-01
Background Smartphone manufacturers offer mobile health monitoring technology to their customers, including apps using the built-in camera for heart rate assessment. This study aimed to test the diagnostic accuracy of such heart rate measuring apps in clinical practice. Methods The feasibility and accuracy of measuring heart rate was tested on four commercially available apps using both iPhone 4 and iPhone 5. 'Instant Heart Rate' (IHR) and 'Heart Fitness' (HF) work with contact photoplethysmography (contact of fingertip to built-in camera), while 'Whats My Heart Rate' (WMH) and 'Cardiio Version' (CAR) work with non-contact photoplethysmography. The measurements were compared to electrocardiogram and pulse oximetry-derived heart rate. Results Heart rate measurement using app-based photoplethysmography was performed on 108 randomly selected patients. The electrocardiogram-derived heart rate correlated well with pulse oximetry ( r = 0.92), IHR ( r = 0.83) and HF ( r = 0.96), but somewhat less with WMH ( r = 0.62) and CAR ( r = 0.60). The accuracy of app-measured heart rate as compared to electrocardiogram, reported as mean absolute error (in bpm ± standard error) was 2 ± 0.35 (pulse oximetry), 4.5 ± 1.1 (IHR), 2 ± 0.5 (HF), 7.1 ± 1.4 (WMH) and 8.1 ± 1.4 (CAR). Conclusions We found substantial performance differences between the four studied heart rate measuring apps. The two contact photoplethysmography-based apps had higher feasibility and better accuracy for heart rate measurement than the two non-contact photoplethysmography-based apps.
Safety Assessment of Alkyl PEG/PPG Ethers as Used in Cosmetics.
Fiume, Monice M; Heldreth, Bart; Bergfeld, Wilma F; Belsito, Donald V; Hill, Ronald A; Klaassen, Curtis D; Liebler, Daniel C; Marks, James G; Shank, Ronald C; Slaga, Thomas J; Snyder, Paul W; Andersen, F Alan
2016-07-01
The Cosmetic Ingredient Review (CIR) Expert Panel assessed the safety of 131 alkyl polyethylene glycol (PEG)/polypropylene glycol ethers as used in cosmetics, concluding that these ingredients are safe in the present practices of use and concentration described in this safety assessment when formulated to be nonirritating. Most of the alkyl PEG/PPG ethers included in this review are reported to function in cosmetics as surfactants, skin-conditioning agents, and/or emulsifying agents. The alkyl PEG/PPG ethers share very similar physiochemical properties as the alkyl PEG ethers, which were reviewed previously by the CIR Expert Panel and found safe when formulated to be nonirritating. The alkyl PEG ethers differ by the inclusion of PPG repeat units, which are used to fine-tune the surfactant properties of this group. The Panel relied heavily on data on analogous ingredients, extracted from the alkyl PEG ethers and PPG reports, when making its determination of safety. © The Author(s) 2016.
Statistical approach for the detection of motion/noise artifacts in Photoplethysmogram.
Selvaraj, Nandakumar; Mendelson, Yitzhak; Shelley, Kirk H; Silverman, David G; Chon, Ki H
2011-01-01
Motion and noise artifacts (MNA) have been a serious obstacle in realizing the potential of Photoplethysmogram (PPG) signals for real-time monitoring of vital signs. We present a statistical approach based on the computation of kurtosis and Shannon Entropy (SE) for the accurate detection of MNA in PPG data. The MNA detection algorithm was verified on multi-site PPG data collected from both laboratory and clinical settings. The accuracy of the fusion of kurtosis and SE metrics for the artifact detection was 99.0%, 94.8% and 93.3% in simultaneously recorded ear, finger and forehead PPGs obtained in a clinical setting, respectively. For laboratory PPG data recorded from a finger with contrived artifacts, the accuracy was 88.8%. It was identified that the measurements from the forehead PPG sensor contained the most artifacts followed by finger and ear. The proposed MNA algorithm can be implemented in real-time as the computation time was 0.14 seconds using Matlab®.
Wearable wireless photoplethysmography sensors
NASA Astrophysics Data System (ADS)
Spigulis, Janis; Erts, Renars; Nikiforovs, Vladimirs; Kviesis-Kipge, Edgars
2008-04-01
Wearable health monitoring sensors may support early detection of abnormal conditions and prevention of their consequences. Recent designs of three wireless photoplethysmography monitoring devices embedded in hat, glove and sock, and connected to PC or mobile phone by means of the Bluetooth technology, are described. First results of distant monitoring of heart rate and pulse wave transit time using the newly developed devices are presented.
Running on Empty? The Compensatory Reserve Index
2013-12-01
peripheral perfusion can be displayed by pulse oximeters , with the photoplethysmographic (PPG) signal being derived from the infrared light absorbtion...existing literature on the cor- relation between features of the pulse oximeter PPG waveform and central blood volume,34Y36 led us to hypothesize that...PPG waveforms generated by Masimo and Nonin pulse oximeters , CRI accuracy results have been obtained for 30 high- and low- tolerant LBNP subjects. CRI
Time-varying spectral analysis for comparison of HRV and PPG variability during tilt table test.
Gil, Eduardo; Orini, Michele; Bailon, Raquel; Vergara, Jose Maria; Mainardi, Luca; Laguna, Pablo
2010-01-01
In this work we assessed the possibility of using the pulse rate variability (PRV) extracted from photoplethysmography signal as an alternative measurement of the HRV signal in non-stationary conditions. The study is based on the analysis of the changes observed during tilt table test in the heart rate modulation of 17 young subjects. Time-varying spectral properties of both signals were compared by time-frequency (TF) and TF coherence analysis. In addition, the effect of replacing PRV with HRV in the assessment of the changes of the autonomic modulation of the heart rate was considered. Time-frequency analysis revealed that: the TF spectra of both signals were highly correlated (0.99 ± 0.01); the difference between the instantaneous power, in LF and HF bands, obtained from HRV and PRV was small (, 10(-3) s(-2)) and their temporal patterns were highly correlated (0.98 ± 0.04 and 0.95 ± 0.06 in LF and HF bands respectively); TF coherence in LF and HF bands was high (0.97 ± 0.04 and 0.89 ± 0.08, respectively). Finally, the instantaneous power in LF band was observed to significantly increase during head-up tilt by both HRV and PRV analysis. These results suggest that, although some small differences in the time-varying spectral indices extracted from HRV and PRV exist, mainly in the HF band associated with respiration, PRV could be used as an acceptable surrogate of HRV during non-stationary conditions, at least during tilt table test.
Detection of Low-volume Blood Loss: Compensatory Reserve Versus Traditional Vital Signs
2014-01-01
studies have demonstrated that photoplethysmogram (PPG) wave forms obtained with a pulse oximeter sensor significantly change with volume loss.5 With this...donation, including PPG wave forms (OEM III pulse oximeter , Nonin, Minneapolis, MN), and a noninvasive BPwave form (ccNexfin, Edwards Lifesciences, Irvine...a PPG wave form obtained with a pulse oximeter sensor. CRI is calculated after 30 heart beats and is recalculated beat-to-beat in a continuous
Yongsu Lee; Hyeonwoo Lee; Seunghyup Yoo; Hoi-Jun Yoo
2016-08-01
The sticker-type sensor system is proposed targeting ECG/PPG concurrent monitoring for cardiovascular diseases. The stickers are composed of two types: Hub and Sensor-node (SN) sticker. Low-power CMOS SoC for measuring ECG and PPG signal is hybrid integrated with organic light emitting diodes (OLEDs) and organic photo detector (OPD). The sticker has only 2g weight and only consumes 141μW. The optical calibration loop is adopted for maintaining SNR of PPG signal higher than 30dB. The pulse arrival time (PAT) and SpO2 value can be extracted from various body parts and verified comparing with the reference device from 20 people in-vivo experiments.
Ghamari, M; Soltanpur, C; Cabrera, S; Romero, R; Martinek, R; Nazeran, H
2016-08-01
Heart Rate Variability (HRV) signal analysis provides a quantitative marker of the Autonomic Nervous System (ANS) function. A wristband-type wireless photoplethysmographic (PPG) device was custom-designed to collect and analyze the arterial pulse in the wrist. The proposed device is comprised of an optical sensor to monitor arterial pulse, a signal conditioning unit to filter and amplify the analog PPG signal, a microcontroller to digitize the analog PPG signal, and a Bluetooth module to transfer the data to a smart device. This paper proposes a novel model to represent the PPG signal as the summation of two Gaussian functions. The paper concludes with a verification procedure for HRV signal analysis during sedentary activities.
Hu, Junfeng; Shao, Qinshu; Sun, Yuanshui; Xu, Xiaodong; Xu, Ji
2015-04-14
To evaluate the long-term outcomes of pylorus-vagus-preserving partial gastrectomy for early gastric cancer in middle third of stomach. Between January 2004 and June 2009, 46 patients with early gastric cancer in middle third of stomach underwent pylorus-vagus-preserving partial gastrectomy (PPG) while another 85 patients had conventional distal gastrectomy (DG). Clinicopathologic data and follow-up results of two groups were analyzed retrospectively, including the results of subjective nutritional assessments, laboratory blood biochemical data, endoscopic findings of remnant stomach and total 5-year survival rates. Postprandial dumping syndrome occurred in 7 patients (8.2%) in DG group while no syndrome occurred in PPG group. The incidence of gallbladder stones at 18 months after operation in DG group was higher than that in PPG group. Significant difference existed between two groups (P<0.05). Even though no significant difference existed in laboratory blood biochemical data and endoscopic findings, PPG group recovered better and regurgitation was frequently found in DG group. Food residue in gastric remnant was frequently observed in PPG (31.1%) than in DG (10.8%, P<0.05) by endoscopic findings. At 2 years post-operation, the postoperative 5-year recurrence rate was 6.5% (2/46) in PPG group versus 8.2% (7/85) in DG group. However no significant difference existed between 2 groups (P=0.724). No significant difference existed between PPG group (91.3%) and DG group (90.6%) in overall 5-year survival rate. For early gastric cancer in middle third of stomach, pylorus-vagus-preserving partial gastrectomy is effective in maintaining postoperative function. And it has the same postoperative survival rate as conventional distal gastrectomy.
Clinical features and treatment of peristomal pyoderma gangrenosum.
Hughes, A P; Jackson, J M; Callen, J P
2000-09-27
Peristomal pyoderma gangrenosum (PPG), an unusual variant of pyoderma gangrenosum, has been reported almost exclusively in patients with inflammatory bowel disease (IBD) and is frequently misdiagnosed. To better characterize the clinical manifestations, diagnosis, and management of PPG. Retrospective analysis of 7 patients with PPG observed in a university-affiliated community setting between 1988 and December 1999. Clinical and histopathologic features, associated disorders, and microbiologic findings. Two patients had Crohn disease, 2 had ulcerative colitis, and 3 had abdominal cancer. Five patients had at least 1 relapse of PPG after initial healing. Although 3 of 4 patients with IBD had active bowel disease, a parallel course with PPG occurred in only 1 patient. Both patients whose stoma was relocated developed an ulcer at the new site. Effective therapies included topical superpotent corticosteroids; intralesional injection of triamcinolone acetonide at the ulcer margin; topical cromolyn sodium; oral dapsone, prednisone, cyclosporine, mycophenolate mofetil; and intravenous infliximab. Our experiences demonstrate that although PPG has been most often reported in patients with IBD, it may occur in the absence of IBD. Biopsy of the skin lesion is not diagnostic but excludes other causes. Relocation of the stoma may be associated with a new ulceration and should be avoided. Trauma to the skin of a predisposed patient may elicit the pustules or ulcerations associated with pathergy. JAMA. 2000;284:1546-1548.
Diagnostic capability of Pulsar perimetry in pre-perimetric and early glaucoma.
Hirasawa, Kazunori; Takahashi, Natsumi; Matsumura, Kazuhiro; Kasahara, Masayuki; Shoji, Nobuyuki
2017-06-12
This study aimed to compare the diagnostic capability of Pulsar perimetry (Pulsar) in pre-perimetric glaucoma (PPG) and early glaucoma (EG) with that of Flicker perimetry (Flicker) and spectral-domain optical conference tomography (SD-OCT). This prospective cross-sectional study included 25 eyes of 25 PPG patients, 35 eyes of 35 EG patients, and 42 eyes of 42 healthy participants. The diagnostic capability using the area under the curve (AUC) of the best parameter and agreement of detectability between structural and functional measurements were compared. For PPG patients, the AUC of Pulsar, Flicker, OCT-disc, and OCT-macular was 0.733, 0.663, 0.842, and 0.780, respectively. The AUC of Flicker was significantly lower than that of OCT-disc (p = 0.016). For EG patients, the AUC of Pulsar, Flicker, OCT-disc, and OCT-macular were 0.851, 0.869, 0.907, and 0.861, respectively. There was no significant difference in AUC among these methods. The agreement between structural and functional measurements expressed by kappa value ranged from -0.16 to 0.07 for PPG and from 0.01 to 0.25 for EG. Although the diagnostic capability of Pulsar in the PPG and EG groups was equal to that of Flicker and SD-OCT, the agreements between structural and functional measurements for both PPG and EG were poor.
A clip-free eyeglasses-based wearable monitoring device for measuring photoplethysmograhic signals.
Zheng, Yali; Leung, Billy; Sy, Stanley; Zhang, Yuanting; Poon, Carmen C Y
2012-01-01
An eyeglasses-based device has been developed in this work to acquire photoplethysmogram (PPG) from the nose bridge. This device is aimed to provide wearable physiological monitoring without uncomfortable clips frequently used in PPG measurement from finger and ear. Switching control is applied on the LED and photo detector for power saving. An experiment involving postural change and treadmill jogging among 10 healthy young subjects was carried out to evaluate the performance of the device. Electrocardiogram (ECG) and PPG from finger, ear and nose were simultaneously recorded, from which heart rate (HR) and pulse transit time (PTT) were calculated. The results show that PPG measured from nose and ear are more resistant to motion than signal from finger during exercise. In addition, the difference between PTT measured from ear and nose indicates that local vasomotor activities may exist on ear and/or nose channel, and suggests that PPG from different sites should be used for cuff-less PTT-based BP estimation. We conclude that this wearable device has great potential to be used in the healthcare management in the future.
Roles of Poly(propylene Glycol) During Solvent-Based Lamination of Ceramic Green Tapes
NASA Technical Reports Server (NTRS)
Suppakarn, Nitinat; Ishida, Hatsuo; Cawley, James D.; Levine, Stanley R. (Technical Monitor)
2000-01-01
Solvent lamination for alumina green tapes is readily accomplished using a mixture of ethanol, toluene and poly(propylene glycol). After lamination, the PPG is clearly present as a discrete film at the interface between the laminated tapes. This condition, however, does not generate delamination during firing. Systematic sets of experiments are undertaken to determine the role of PPG in the lamination process and, specifically, the mechanism by which it is redistributed during subsequent processing. PPG slowly diffuses through the organic binder film at room temperature. The PPG diffusion rapidly increases as temperature is increased to 80 C. The key to the efficiency of adhesives during green-tape lamination is mutual solubility of the nonvolatile component of the glue and the base polymeric binder.
CURRENT SITUATION OF MEDICINE III AND CHALLENGES.
Ferreira, Lydia Masako
2015-01-01
Describe the current situation of the area Medicine III of CAPES and detect challenges for the next four years of evaluation. The area's documents and reports of meetings were read from 2004 to 2013 Medicine III Capes as well as reports and evaluation form of each Postgraduate Program (PPG) of the area and the sub-page of the area from the Capes website. The data relating to the evaluation process, the assessment form and faculty, student and scientific production data of all of Post-Graduate Programs of Medicine III were computed and analyzed. From these data were detected the challenges of the area for the next four years (2013-2016). Among the 3,806 PPG, Medicine III had 41 PPG during last triennial evaluation and progressed from 18% to 43% of PPG very good or more concept (triennium 2001-2003 and 2010-2012). Most PPG were located in the South-East region (32), three in the South and two in the North-East. There was no PPG in North or Central-West regions. In 2013 and 2014 there were four approved Professional Master Degree Programs and one Master (M) and Doctorate (PhD). The average of permanent professors was 558 teachers with about three students/professor. The number of PhD graduates has increased as well as the reason PhD/MD. The proportion of in high impact periodicals (A1, A2, B1 and B2) jumped from 30% to 50% demonstrating positive community response to the policy area. The challenges identified were: decrease regional asymmetry, increase the number of masters and doctors of excellence, reassessment of Brazilian journals, stimulate and set internationalization indicators, including post-doctors and definition of its indicators, the PPG nucleation analysis, PPG 3x3, include primary and secondary education, professional master and indicators of technological scientific production and solidarity. Medicine III has been scientifically consolidated and their scientific researchers demonstrated maturity reaching a high level and matched to areas of greatest tradition and history. For the maintenance and advancement of the area some challenges and goals were established to be developed in the period from 2013 to 2016. Descrever a situação atual da área Medicina III da Capes e detectar os desafios para o próximo quadriênio de avaliação. Os documentos e relatórios de reuniões de área a partir de 2004 até 2013 da Medicina III da Capes foram lidos assim como os relatórios e as fichas de avaliação de cada Programa de Pós Graduação (PPG) da área e a subpágina da área no site da Capes. Os dados referentes ao Processo de Avaliação, à Ficha de Avaliação e aos dados do Corpo Docente, Discente e Produção científica de todos os PPG da Medicina III foram computados e analisados. A partir desses dados foram detectados os desafios da área para o próximo quadriênio (2013-2016). Dentre os 3.806 PPG, a Medicina III apresentava 41 PPG durante última avaliação trienal e evoluiu de 18% para 43% de PPG > conceito muito bom (Triênios 2001-2003 e 2010-2012). A maioria dos PPG se localizavam na Região Sudeste (32), três no Sul e dois no Nordeste. Não havia nenhum PPG no Norte ou Centro-Oeste. Em 2013 e 2014 foram aprovadas quatro mestrados profissionais e um mestrado e doutorado acadêmico. A média de docente permanente no triênio foi de 558 docentes com cerca de três alunos titulados/docente. O número de doutores titulados tem aumentado assim como a razão Doutorado/Mestrado. A proporção de publicações em periódicos de maior impacto (A1, A2, B1 e B2) saltou de 30% para 50% demonstrando resposta positiva da comunidade à política da área. Os desafios detectados foram: diminuir assimetria regional, elevar o número de mestres e doutores de excelência, reavaliação das revistas nacionais, estimular e definir indicadores de internacionalização, inclusão de pós-doutores e definição de seus indicadores, análise da nucleação do PPG, PPG 3x3, inclusão ensino médio e fundamental, mestrado profissional e indicadores da produção científico-tecnológica e solidariedade. A Medicina III tem se consolidado cientificamente e seus pesquisadores demonstraram maturidade científica chegando a um patamar elevado e igualado às áreas de maior tradição e história. Para a manutenção e avanço da área alguns desafios e metas foram traçadas para serem desenvolvidas no quadriênio 2013-2016.
Grants Policy Issuance (GPI) 15-01: Performance Partnership Grants for States
This policy increases awareness of the administrative and programmatic flexibility available through Performance Partnership Grants (PPGs), encourages PPG use and ensures consistent PPG implementation and management.
1994-12-01
PPG1160-BP, PPG1290-BP, and PPG1290-BPE were examined by x - ray diffraction.12 The plain ionenes and their simple TCNQ salts were amorphous. The...iodine. X - ray and infrared data supported the concept that 42-13 polycrystalline PA existed within amorphous PB. The PA in the blend, depending on...assessed by in situ Auger Spectroscopy or X - ray Photoelectron Spectroscopy. The typical values of surface concentration enhancement of a diluted
Simultaneous Monitoring of Ballistocardiogram and Photoplethysmogram Using Camera
Shao, Dangdang; Tsow, Francis; Liu, Chenbin; Yang, Yuting; Tao, Nongjian
2017-01-01
We present a noncontact method to measure Ballistocardiogram (BCG) and Photoplethysmogram (PPG) simultaneously using a single camera. The method tracks the motion of facial features to determine displacement BCG, and extracts the corresponding velocity and acceleration BCGs by taking first and second temporal derivatives from the displacement BCG, respectively. The measured BCG waveforms are consistent with those reported in literature and also with those recorded with an accelerometer-based reference method. The method also tracks PPG based on the reflected light from the same facial region, which makes it possible to track both BCG and PPG with the same optics. We verify the robustness and reproducibility of the noncontact method with a small pilot study with 23 subjects. The presented method is the first demonstration of simultaneous BCG and PPG monitoring without wearing any extra equipment or marker by the subject. PMID:27362754
Accurate Heart Rate Monitoring During Physical Exercises Using PPG.
Temko, Andriy
2017-09-01
The challenging task of heart rate (HR) estimation from the photoplethysmographic (PPG) signal, during intensive physical exercises, is tackled in this paper. The study presents a detailed analysis of a novel algorithm (WFPV) that exploits a Wiener filter to attenuate the motion artifacts, a phase vocoder to refine the HR estimate and user-adaptive post-processing to track the subject physiology. Additionally, an offline version of the HR estimation algorithm that uses Viterbi decoding is designed for scenarios that do not require online HR monitoring (WFPV+VD). The performance of the HR estimation systems is rigorously compared with existing algorithms on the publically available database of 23 PPG recordings. On the whole dataset of 23 PPG recordings, the algorithms result in average absolute errors of 1.97 and 1.37 BPM in the online and offline modes, respectively. On the test dataset of 10 PPG recordings which were most corrupted with motion artifacts, WFPV has an error of 2.95 BPM on its own and 2.32 BPM in an ensemble with two existing algorithms. The error rate is significantly reduced when compared with the state-of-the art PPG-based HR estimation methods. The proposed system is shown to be accurate in the presence of strong motion artifacts and in contrast to existing alternatives has very few free parameters to tune. The algorithm has a low computational cost and can be used for fitness tracking and health monitoring in wearable devices. The MATLAB implementation of the algorithm is provided online.
Spatial and temporal distribution of Pu in the Northwest Pacific Ocean using modern coral archives.
Lindahl, Patric; Andersen, Morten B; Keith-Roach, Miranda; Worsfold, Paul; Hyeong, Kiseong; Choi, Min-Seok; Lee, Sang-Hoon
2012-04-01
Historical (239)Pu activity concentrations and (240)Pu/(239)Pu atom ratios were determined in skeletons of dated modern corals collected from three locations (Chuuk Lagoon, Ishigaki Island and Iki Island) to identify spatial and temporal variations in Pu inputs to the Northwest Pacific Ocean. The main Pu source in the Northwest Pacific is fallout from atmospheric nuclear weapons testing which consists of global fallout and close-in fallout from the former US Pacific Proving Grounds (PPG) in the Marshall Islands. PPG close-in fallout dominated the Pu input in the 1950s, as was observed with higher (240)Pu/(239)Pu atom ratios (>0.30) at the Ishigaki site. Specific fallout Pu contamination from the Nagasaki atomic bomb and the Ivy Mike thermonuclear detonation at the PPG were identified at Ishigaki Island from the (240)Pu/(239)Pu atom ratios of 0.07 and 0.46, respectively. During the 1960s and 1970s, global fallout was the major Pu source to the Northwest Pacific with over 60% contribution to the total Pu. After the cessation of the atmospheric nuclear tests, the PPG again dominated the Pu input due to the continuous transport of remobilised Pu from the Marshall Islands along the North Equatorial Current and the subsequent Kuroshio Current. The Pu contributions from the PPG in recent coral bands (1984 onwards) varied over time with average estimated PPG contributions between 54% and 72% depending on location. Copyright © 2011 Elsevier Ltd. All rights reserved.
Jing Liu; Yuan-Ting Zhang; Xiao-Rong Ding; Wen-Xuan Dai; Ni Zhao
2016-08-01
Pulse transit time (PTT) has been widely studied as an index of blood pressure (BP) changes. In recent years, some prototypes of PTT-based wearable BP measurement devices have been developed, which can relieve users from the discomfort caused by the inflating cuff used in auscultatory and oscillometric BP measurement techniques. However, in the common practice for PTT detection, multi-site sensor implementation on human body is required, making it difficult for the integration of wearable devices. Since multi-wavelength (MW) photoplethysmogram (PPG) signals carry blood pulsation information of different blood vessels embedded in different skin depths, the time difference between different wavelength PPG signals collected at the same body site can be treated as a special PTT on a short length of blood vessels beneath the skin. In this work, the time difference between MW PPG, denoted as PTT_MW, was explored to track BP changes as a substitute of infrared (IR) PTT_EP. (PTT_EP is the time interval between electrocardiogram (ECG) and IR PPG.) Ten healthy adult subjects participated in the experiment, and their continuous BP, ECG and fingertip MW PPG signals generated from blue, green, yellow and IR light were recorded after 2-minute static handgrip exercise at 33% maximal voluntary contraction. The results showed that the correlation between Systolic BP (SBP) and IR-Blue PTT_MW (|r|= 0.52) was comparable to the correlation between SBP and IR PTT_EP (|r|= 0.59). Moreover, we optimized the wavelength combination of PTT_MWs for each subject and found the average value of optimal correlation between SBP and PTT_MW reached 0.76, which was significantly (p<;0.01) higher than the correlation between IR PTT_EP and SBP. This study reveals that the time difference between MW PPG can be potentially used as PTT for cuffless BP measurement with its unique advantage in simple sensor implementation at only one body site.
Optimal spacing between transmitting and receiving optical fibres in reflectance pulse oximetry
NASA Astrophysics Data System (ADS)
Hickey, M.; Kyriacou, P. A.
2007-10-01
Splanchnic ischaemia can ultimately lead to cellular hypoxia and necrosis, and may well contribute to the development of multiple organ failures and increased mortality. Therefore, it is of utmost importance to monitor abdominal organ blood oxygen saturation (SpO2). Pulse oximetry has been widely accepted as a reliable method for monitoring oxygen saturation of arterial blood. Animal studies have also shown it to be effective in the monitoring of blood oxygen saturation in the splanchnic region. However, commercially available pulse oximeter probes are not suitable for the continuous assessment of SpO2 in the splanchnic region. Therefore, there is a need for a new sensor technology that will allow the continuous measurement of SpO2 in the splanchnic area pre-operatively, operatively and post-operatively. For this purpose, a new fibre optic sensor and processing system utilising the principle of reflectance pulse oximetry has been developed. The accuracy in the estimation of SpO2 in pulse oximetry depends on the quality and amplitude of the photoplethysmographic (PPG) signal and for this reason an experimental procedure was carried out to examine the effect of the source-detector separation distance on the acquired PPG signals, and to ultimately select an optimal separation for the final design of the fibre-optic probe. PPG signals were obtained from the finger for different separation distances between the emitting and detecting fibres. Good quality PPG signals with large amplitudes and high signal-to-noise ratio were detected in the range of 3mm to 6mm. At separation distances between 1mm and 2mm, PPG signals were erratic with no resemblance to a conventional PPG signal. At separation distances greater than 6mm, the amplitudes of PPG signals were very small and not appropriate for processing. This investigation indicates the suitability of optical fibres as a new pulse oximetry sensor for estimating blood oxygen saturation (SpO2) in the splanchnic region.
NASA Astrophysics Data System (ADS)
Cheng, Chih-Chia; Chang, Feng-Chih; Wang, Jui-Hsu; Chen, Jem-Kun; Yen, Ying-Chieh; Lee, Duu-Jong
2015-12-01
A novel urea-cytosine end-capped polypropylene glycol (UrCy-PPG) can self-assemble into a long-range ordered lamellar microstructure on the surface of graphene, due to the strong specific interactions between UrCy-PPG and graphene. In addition, the graphene composite produced exhibits a high conductivity (~1093 S m-1) with a dramatic thermo-responsive ON/OFF resistance-switching behavior (10 consecutive cycles).A novel urea-cytosine end-capped polypropylene glycol (UrCy-PPG) can self-assemble into a long-range ordered lamellar microstructure on the surface of graphene, due to the strong specific interactions between UrCy-PPG and graphene. In addition, the graphene composite produced exhibits a high conductivity (~1093 S m-1) with a dramatic thermo-responsive ON/OFF resistance-switching behavior (10 consecutive cycles). Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr07076g
Lee, Won June; Kim, Young Kook; Jeoung, Jin Wook; Park, Ki Ho
2017-12-01
To determine the usefulness of swept-source optical coherence tomography (SS-OCT) probability maps in detecting locations with significant reduction in visual field (VF) sensitivity or predicting future VF changes, in patients with classically defined preperimetric glaucoma (PPG). Of 43 PPG patients, 43 eyes were followed-up on every 6 months for at least 2 years were analyzed in this longitudinal study. The patients underwent wide-field SS-OCT scanning and standard automated perimetry (SAP) at the time of enrollment. With this wide-scan protocol, probability maps originating from the corresponding thickness map and overlapped with SAP VF test points could be generated. We evaluated the vulnerable VF points with SS-OCT probability maps as well as the prevalence of locations with significant VF reduction or subsequent VF changes observed in the corresponding damaged areas of the probability maps. The vulnerable VF points were shown in superior and inferior arcuate patterns near the central fixation. In 19 of 43 PPG eyes (44.2%), significant reduction in baseline VF was detected within the areas of structural change on the SS-OCT probability maps. In 16 of 43 PPG eyes (37.2%), subsequent VF changes within the areas of SS-OCT probability map change were observed over the course of the follow-up. Structural changes on SS-OCT probability maps could detect or predict VF changes using SAP, in a considerable number of PPG eyes. Careful comparison of probability maps with SAP results could be useful in diagnosing and monitoring PPG patients in the clinical setting.
Herzner, Gudrun; Ruther, Joachim; Goller, Stephan; Schulz, Stefan; Goettler, Wolfgang; Strohm, Erhard
2011-02-01
The postpharyngeal gland (PPG) plays a major role in the social integration of ant colonies. It had been thought to be restricted to ants but was recently also described for a solitary wasp, the European beewolf (Philanthus triangulum). This finding posed the question whether the gland has evolved independently in the two taxa or has been inherited from a common ancestor and is hence homologous. The latter alternative would be supported if a PPG was found in more basal taxa. Therefore, we examined a species at the base of the Apoidea, the solitary ampulicid wasp Ampulex compressa, for the existence of a PPG. Both sexes of this species possess a cephalic gland that branches off the posterior part of the pharynx, is lined by a cuticular intima and surrounded by a monolayered epithelium with the epithelial cells bearing long hairs. Most of these morphological characteristics conform to those of the PPG of ants and beewolves. Chemical analysis of the gland content revealed that it contains mainly hydrocarbons and that there is a congruence of the pattern of hydrocarbons in the gland, on the cuticle, and in the hemolymph, as has also been reported for both ants and beewolves. Based on these morphological and chemical results we propose that the newly described cephalic gland is a PPG and discuss its possible function in A. compressa. The present study supports the view of a homologous origin of the PPG in the aculeate Hymenoptera. Copyright © 2010 Elsevier GmbH. All rights reserved.
Charlton, Peter H; Bonnici, Timothy; Tarassenko, Lionel; Alastruey, Jordi; Clifton, David A; Beale, Richard; Watkinson, Peter J
2017-05-01
Breathing rate (BR) can be estimated by extracting respiratory signals from the electrocardiogram (ECG) or photoplethysmogram (PPG). The extracted respiratory signals may be influenced by several technical and physiological factors. In this study, our aim was to determine how technical and physiological factors influence the quality of respiratory signals. Using a variety of techniques 15 respiratory signals were extracted from the ECG, and 11 from PPG signals collected from 57 healthy subjects. The quality of each respiratory signal was assessed by calculating its correlation with a reference oral-nasal pressure respiratory signal using Pearson's correlation coefficient. Relevant results informing device design and clinical application were obtained. The results informing device design were: (i) seven out of 11 respiratory signals were of higher quality when extracted from finger PPG compared to ear PPG; (ii) laboratory equipment did not provide higher quality of respiratory signals than a clinical monitor; (iii) the ECG provided higher quality respiratory signals than the PPG; (iv) during downsampling of the ECG and PPG significant reductions in quality were first observed at sampling frequencies of <250 Hz and <16 Hz respectively. The results informing clinical application were: (i) frequency modulation-based respiratory signals were generally of lower quality in elderly subjects compared to young subjects; (ii) the qualities of 23 out of 26 respiratory signals were reduced at elevated BRs; (iii) there were no differences associated with gender. Recommendations based on the results are provided regarding device designs for BR estimation, and clinical applications. The dataset and code used in this study are publicly available.
NASA Astrophysics Data System (ADS)
Alharbi, Samah; Hu, Sijung; Mulvaney, David; Blanos, Panagiotis
2018-02-01
The ability to gather physiological parameters such as heart rate (HR) and oxygen saturation (SpO2%) during physical movement allows to continuously monitor personal health status without disrupt their normal daily activities. Photoplethysmography (PPG) based pulse oximetry and similar principle devices are unable to extract the HR and SpO2% reliably during physical movement due to interference in the signals that arise from motion artefacts (MAs). In this research, a flexible reflectance multi-wavelength optoelectronic patch sensor (OEPS) has been developed to overcome the susceptibility of conventional pulse oximetry readings to MAs. The OEPS incorporates light embittered diodes as illumination sources with four different wavelengths, e.g. green, orange, red, and infrared unlike the conventional pulse oximetry devices that normally measure the skin absorption of only two wavelengths (red and infrared). The additional green and orange wavelengths were found to be distinguish to the absorption of deoxyhemoglobin (RHb) and oxyhemoglobin (HbO2). The reliability of extracting physiological parameters from the green and orange wavelengths is due to absorbed near to the surface of the skin, thereby shortening the optical path and so effectively reducing the influence of physical movements. To compensate of MAs, a three-axis accelerometer was used as a reference with help of adaptive filter to reduce MAs. The experiments were performed using 15 healthy subjects aged 20 to 30. The primary results show that there are no significant difference of heart rate and oxygen saturation measurements between commercial devices and OEPS Green (r=0.992), Orange(r=0.984), Red(r=0.952) and IR(r=0.97) and SpO2% (r = 0.982, p = 0.894).
Measurement of splanchnic photoplethysmographic signals using a new reflectance fiber optic sensor
NASA Astrophysics Data System (ADS)
Hickey, Michelle; Samuels, Neal; Randive, Nilesh; Langford, Richard M.; Kyriacou, Panayiotis A.
2010-03-01
Splanchnic organs are particularly vulnerable to hypoperfusion. Currently, there is no technique that allows for the continuous estimation of splanchnic blood oxygen saturation (SpO2). As a preliminary to developing a suitable splanchnic SpO2 sensor, a new reflectance fiber optic photoplethysmographic (PPG) sensor and processing system are developed. An experimental procedure to examine the effect of fiber source detector separation distance on acquired PPG signals is carried out before finalizing the sensor design. PPG signals are acquired from four volunteers for separation distances of 1 to 8 mm. The separation range of 3 to 6 mm provides the best quality PPG signals with large amplitudes and the highest signal-to-noise ratios (SNRs). Preliminary calculation of SpO2 shows that distances of 3 and 4 mm provide the most realistic values. Therefore, it is suggested that the separation distance in the design of a fiber optic reflectance pulse oximeter be in the range of 3 to 4 mm. Preliminary PPG signals from various splanchnic organs and the periphery are obtained from six anaesthetized patients. The normalized amplitudes of the splanchnic PPGs are, on average, approximately the same as those obtained simultaneously from the periphery. These observations suggest that fiber optic pulse oximetry may be a valid monitoring technique for splanchnic organs.
Li, Baotong; Wu, Hengchao; Sun, Hansong; Xu, Jianping; Song, Yunhu; Wang, Wei; Wang, Shuiyun
2018-03-07
Although it has been realized that restrictive mitral valve annuloplasty (MVA) may result in clinically significant functional mitral stenosis (MS), it still cannot be predicted. The purpose of this study was to identify risk factors for clinically significant functional MS following restrictive MVA surgery for chronic ischemic mitral regurgitation (CIMR). 114 patients who underwent restrictive MVA with coronary artery bypass grafting (CABG) for treatment of CIMR were retrospectively reviewed. Clinically significant functional MS was defined as resting transmitral peak pressure gradient (PPG) ≥ 13 mmHg. During the follow-up period (range 6-12 months), 28 (24.56%) patients developed clinically significant functional MS. The PPG at follow-up was significantly higher than that measured in the early postoperative stage (3-5 days after surgery). Moreover, there was a linear correlation between the two measurements (r = 0.398, p < 0.001). Annuloplasty size ≤ 27 mm and early postoperative PPG ≥ 7.4 mmHg could predict clinically significant functional MS at 6-12 months postoperatively. Chronic ischemic mitral regurgitation patients treated with restrictive MVA and CABG have significant increases in PPG postoperatively. Annuloplasty size ≤ 27 mm and early postoperative PPG ≥ 7.4 mmHg can predict clinically significant functional MS at 6-12 months after surgery.
Improved bioactivity of G-rich triplex-forming oligonucleotides containing modified guanine bases
Rogers, Faye A; Lloyd, Janice A; Tiwari, Meetu Kaushik
2014-01-01
Triplex structures generated by sequence-specific triplex-forming oligonucleotides (TFOs) have proven to be promising tools for gene targeting strategies. In addition, triplex technology has been highly utilized to study the molecular mechanisms of DNA repair, recombination and mutagenesis. However, triplex formation utilizing guanine-rich oligonucleotides as third strands can be inhibited by potassium-induced self-association resulting in G-quadruplex formation. We report here that guanine-rich TFOs partially substituted with 8-aza-7-deaza-guanine (PPG) have improved target site binding in potassium compared with TFOs containing the natural guanine base. We designed PPG-substituted TFOs to bind to a polypurine sequence in the supFG1 reporter gene. The binding efficiency of PPG-substituted TFOs to the target sequence was analyzed using electrophoresis mobility gel shift assays. We have determined that in the presence of potassium, the non-substituted TFO, AG30 did not bind to its target sequence, however binding was observed with the PPG-substituted AG30 under conditions with up to 140 mM KCl. The PPG-TFOs were able to maintain their ability to induce genomic modifications as measured by an assay for gene-targeted mutagenesis. In addition, these compounds were capable of triplex-induced DNA double strand breaks, which resulted in activation of apoptosis. PMID:25483840
Biometric Authentication Using the PPG: A Long-Term Feasibility Study
Alesanco, Álvaro
2018-01-01
The photoplethysmogram (PPG) is a biomedical signal that can be used to estimate volumetric blood flow changes in the peripheral circulation. During the past few years, several works have been published in order to assess the potential for PPGs to be used in biometric authentication systems, but results are inconclusive. In this paper we perform an analysis of the feasibility of using the PPG as a realistic biometric alternative in the long term. Several feature extractors (based on the time domain and the Karhunen–Loève transform) and matching metrics (Manhattan and Euclidean distances) have been tested using four different PPG databases (PRRB, MIMIC-II, Berry, and Nonin). We show that the false match rate (FMR) and false non-match rate (FNMR) values remain constant in different time instances for a selected threshold, which is essential for using the PPG for biometric authentication purposes. On the other hand, obtained equal error rate (EER) values for signals recorded during the same session range from 1.0% for high-quality signals recorded in controlled conditions to 8% for those recorded in conditions closer to real-world scenarios. Moreover, in certain scenarios, EER values rise up to 23.2% for signals recorded over different days, signaling that performance degradation could take place with time. PMID:29751681
Biometric Authentication Using the PPG: A Long-Term Feasibility Study.
Sancho, Jorge; Alesanco, Álvaro; García, José
2018-05-11
The photoplethysmogram (PPG) is a biomedical signal that can be used to estimate volumetric blood flow changes in the peripheral circulation. During the past few years, several works have been published in order to assess the potential for PPGs to be used in biometric authentication systems, but results are inconclusive. In this paper we perform an analysis of the feasibility of using the PPG as a realistic biometric alternative in the long term. Several feature extractors (based on the time domain and the Karhunen⁻Loève transform) and matching metrics (Manhattan and Euclidean distances) have been tested using four different PPG databases (PRRB, MIMIC-II, Berry, and Nonin). We show that the false match rate ( FMR ) and false non-match rate ( FNMR ) values remain constant in different time instances for a selected threshold, which is essential for using the PPG for biometric authentication purposes. On the other hand, obtained equal error rate (EER) values for signals recorded during the same session range from 1.0% for high-quality signals recorded in controlled conditions to 8% for those recorded in conditions closer to real-world scenarios. Moreover, in certain scenarios, EER values rise up to 23.2% for signals recorded over different days, signaling that performance degradation could take place with time.
Dao, Duy; Salehizadeh, S M A; Noh, Yeonsik; Chong, Jo Woon; Cho, Chae Ho; McManus, Dave; Darling, Chad E; Mendelson, Yitzhak; Chon, Ki H
2017-09-01
Motion and noise artifacts (MNAs) impose limits on the usability of the photoplethysmogram (PPG), particularly in the context of ambulatory monitoring. MNAs can distort PPG, causing erroneous estimation of physiological parameters such as heart rate (HR) and arterial oxygen saturation (SpO2). In this study, we present a novel approach, "TifMA," based on using the time-frequency spectrum of PPG to first detect the MNA-corrupted data and next discard the nonusable part of the corrupted data. The term "nonusable" refers to segments of PPG data from which the HR signal cannot be recovered accurately. Two sequential classification procedures were included in the TifMA algorithm. The first classifier distinguishes between MNA-corrupted and MNA-free PPG data. Once a segment of data is deemed MNA-corrupted, the next classifier determines whether the HR can be recovered from the corrupted segment or not. A support vector machine (SVM) classifier was used to build a decision boundary for the first classification task using data segments from a training dataset. Features from time-frequency spectra of PPG were extracted to build the detection model. Five datasets were considered for evaluating TifMA performance: (1) and (2) were laboratory-controlled PPG recordings from forehead and finger pulse oximeter sensors with subjects making random movements, (3) and (4) were actual patient PPG recordings from UMass Memorial Medical Center with random free movements and (5) was a laboratory-controlled PPG recording dataset measured at the forehead while the subjects ran on a treadmill. The first dataset was used to analyze the noise sensitivity of the algorithm. Datasets 2-4 were used to evaluate the MNA detection phase of the algorithm. The results from the first phase of the algorithm (MNA detection) were compared to results from three existing MNA detection algorithms: the Hjorth, kurtosis-Shannon entropy, and time-domain variability-SVM approaches. This last is an approach recently developed in our laboratory. The proposed TifMA algorithm consistently provided higher detection rates than the other three methods, with accuracies greater than 95% for all data. Moreover, our algorithm was able to pinpoint the start and end times of the MNA with an error of less than 1 s in duration, whereas the next-best algorithm had a detection error of more than 2.2 s. The final, most challenging, dataset was collected to verify the performance of the algorithm in discriminating between corrupted data that were usable for accurate HR estimations and data that were nonusable. It was found that on average 48% of the data segments were found to have MNA, and of these, 38% could be used to provide reliable HR estimation.
Lee, Won June; Na, Kyeong Ik; Kim, Young Kook; Jeoung, Jin Wook; Park, Ki Ho
2017-06-01
To evaluate the diagnostic ability of wide-field retinal nerve fiber layer (RNFL) maps with swept-source optical coherence tomography (SS-OCT) for detection of preperimetric (PPG) and early perimetric glaucoma (EG). One hundred eighty-four eyes, including 67 healthy eyes, 43 eyes with PPG, and 74 eyes with EG, were analyzed. Patients underwent a comprehensive ocular examination including red-free RNFL photography, visual field testing and wide-field SS-OCT scanning (DRI-OCT-1 Atlantis; Topcon, Tokyo, Japan). SS-OCT provides a wide-field RNFL thickness map and a SuperPixel map, which are composed of the RNFL deviation map of the peripapillary area and the deviation map of the composition of the ganglion cell layer with the inner plexiform layer and RNFL (GC-IPL+RNFL) in the macular area. The ability to discriminate PPG and EG from healthy eyes was assessed using sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) for all parameters and criteria provided by the wide-field SS-OCT scan. The wide-field RNFL thickness map using SS-OCT showed the highest sensitivity of PPG-diagnostic and EG-diagnostic performance compared with the other SS-OCT criteria based on the internal normative base (93.0 and 97.3%, respectively). Among the SS-OCT continuous parameters, the RFNL thickness of the 7 clock-hour, inferior and inferotemporal macular ganglion cell analyses showed the largest AUC of PPG-diagnostic and EG-diagnostic performance (AUC=0.809 to 0.865). The wide-field RNFL thickness map using SS-OCT performed well in distinguishing eyes with PPG and EG from healthy eyes. In the clinical setting, wide-field RNFL maps of SS-OCT can be useful tools for detection of early-stage glaucoma.
Valenza, Gaetano; Iozzia, Luca; Cerina, Luca; Mainardi, Luca; Barbieri, Riccardo
2018-05-01
There is a fast growing interest in the use of non-contact devices for health and performance assessment in humans. In particular, the use of non-contact videophotoplethysmography (vPPG) has been recently demonstrated as a feasible way to extract cardiovascular information. Nevertheless, proper validation of vPPG-derived heartbeat dynamics is still missing. We aim to an in-depth validation of time-varying, linear and nonlinear/complex dynamics of the pulse rate variability extracted from vPPG. We apply inhomogeneous pointprocess nonlinear models to assess instantaneous measures defined in the time, frequency, and bispectral domains as estimated through vPPG and standard ECG. Instantaneous complexity measures, such as the instantaneous Lyapunov exponents and the recently defined inhomogeneous point-process approximate and sample entropy, were estimated as well. Video recordings were processed using our recently proposed method based on zerophase principal component analysis. Experimental data were gathered from 60 young healthy subjects (age: 24±3 years) undergoing postural changes (rest-to-stand maneuver). Group averaged results show that there is an overall agreement between linear and nonlinear/complexity indices computed from ECG and vPPG during resting state conditions. However, important differences are found, particularly in the bispectral and complexity domains, in recordings where the subjects has been instructed to stand up. Although significant differences exist between cardiovascular estimates from vPPG and ECG, it is very promising that instantaneous sympathovagal changes, as well as time-varying complex dynamics, were correctly identified, especially during resting state. In addition to a further improvement of the video signal quality, more research is advocated towards a more precise estimation of cardiovascular dynamics by a comprehensive nonlinear/complex paradigm specifically tailored to the non-contact quantification. Schattauer GmbH.
Couceiro, R; Carvalho, P; Paiva, R P; Henriques, J; Muehlsteff, J
2014-12-01
The presence of motion artifacts in photoplethysmographic (PPG) signals is one of the major obstacles in the extraction of reliable cardiovascular parameters in continuous monitoring applications. In the current paper we present an algorithm for motion artifact detection based on the analysis of the variations in the time and the period domain characteristics of the PPG signal. The extracted features are ranked using a normalized mutual information feature selection algorithm and the best features are used in a support vector machine classification model to distinguish between clean and corrupted sections of the PPG signal. The proposed method has been tested in healthy and cardiovascular diseased volunteers, considering 11 different motion artifact sources. The results achieved by the current algorithm (sensitivity--SE: 84.3%, specificity--SP: 91.5% and accuracy--ACC: 88.5%) show that the current methodology is able to identify both corrupted and clean PPG sections with high accuracy in both healthy (ACC: 87.5%) and cardiovascular diseases (ACC: 89.5%) context.
Chong, Jo Woon; Dao, Duy K; Salehizadeh, S M A; McManus, David D; Darling, Chad E; Chon, Ki H; Mendelson, Yitzhak
2014-11-01
Motion and noise artifacts (MNA) are a serious obstacle in utilizing photoplethysmogram (PPG) signals for real-time monitoring of vital signs. We present a MNA detection method which can provide a clean vs. corrupted decision on each successive PPG segment. For motion artifact detection, we compute four time-domain parameters: (1) standard deviation of peak-to-peak intervals (2) standard deviation of peak-to-peak amplitudes (3) standard deviation of systolic and diastolic interval ratios, and (4) mean standard deviation of pulse shape. We have adopted a support vector machine (SVM) which takes these parameters from clean and corrupted PPG signals and builds a decision boundary to classify them. We apply several distinct features of the PPG data to enhance classification performance. The algorithm we developed was verified on PPG data segments recorded by simulation, laboratory-controlled and walking/stair-climbing experiments, respectively, and we compared several well-established MNA detection methods to our proposed algorithm. All compared detection algorithms were evaluated in terms of motion artifact detection accuracy, heart rate (HR) error, and oxygen saturation (SpO2) error. For laboratory controlled finger, forehead recorded PPG data and daily-activity movement data, our proposed algorithm gives 94.4, 93.4, and 93.7% accuracies, respectively. Significant reductions in HR and SpO2 errors (2.3 bpm and 2.7%) were noted when the artifacts that were identified by SVM-MNA were removed from the original signal than without (17.3 bpm and 5.4%). The accuracy and error values of our proposed method were significantly higher and lower, respectively, than all other detection methods. Another advantage of our method is its ability to provide highly accurate onset and offset detection times of MNAs. This capability is important for an automated approach to signal reconstruction of only those data points that need to be reconstructed, which is the subject of the companion paper to this article. Finally, our MNA detection algorithm is real-time realizable as the computational speed on the 7-s PPG data segment was found to be only 7 ms with a Matlab code.
Yang, Chenxi; Tavassolian, Negar
2018-05-01
This work proposes a novel method of pulse transit time (PTT) measurement. The proximal arterial location data are collected from seismocardiogram (SCG) recordings by placing a micro-electromechanical accelerometer on the chest wall. The distal arterial location data are recorded using an acoustic sensor placed inside the ear. The performance of distal location recordings is evaluated by comparing SCG-acoustic and SCG-photoplethysmogram (PPG) measurements. PPG and acoustic performances under motion noise are also compared. Experimental results suggest comparable performances for the acoustic-based and PPG-based devices. The feasibility of each PTT measurement method is validated for blood pressure evaluations and its limitations are analyzed.
Salehizadeh, Seyed M. A.; Dao, Duy; Bolkhovsky, Jeffrey; Cho, Chae; Mendelson, Yitzhak; Chon, Ki H.
2015-01-01
Accurate estimation of heart rates from photoplethysmogram (PPG) signals during intense physical activity is a very challenging problem. This is because strenuous and high intensity exercise can result in severe motion artifacts in PPG signals, making accurate heart rate (HR) estimation difficult. In this study we investigated a novel technique to accurately reconstruct motion-corrupted PPG signals and HR based on time-varying spectral analysis. The algorithm is called Spectral filter algorithm for Motion Artifacts and heart rate reconstruction (SpaMA). The idea is to calculate the power spectral density of both PPG and accelerometer signals for each time shift of a windowed data segment. By comparing time-varying spectra of PPG and accelerometer data, those frequency peaks resulting from motion artifacts can be distinguished from the PPG spectrum. The SpaMA approach was applied to three different datasets and four types of activities: (1) training datasets from the 2015 IEEE Signal Process. Cup Database recorded from 12 subjects while performing treadmill exercise from 1 km/h to 15 km/h; (2) test datasets from the 2015 IEEE Signal Process. Cup Database recorded from 11 subjects while performing forearm and upper arm exercise. (3) Chon Lab dataset including 10 min recordings from 10 subjects during treadmill exercise. The ECG signals from all three datasets provided the reference HRs which were used to determine the accuracy of our SpaMA algorithm. The performance of the SpaMA approach was calculated by computing the mean absolute error between the estimated HR from the PPG and the reference HR from the ECG. The average estimation errors using our method on the first, second and third datasets are 0.89, 1.93 and 1.38 beats/min respectively, while the overall error on all 33 subjects is 1.86 beats/min and the performance on only treadmill experiment datasets (22 subjects) is 1.11 beats/min. Moreover, it was found that dynamics of heart rate variability can be accurately captured using the algorithm where the mean Pearson’s correlation coefficient between the power spectral densities of the reference and the reconstructed heart rate time series was found to be 0.98. These results show that the SpaMA method has a potential for PPG-based HR monitoring in wearable devices for fitness tracking and health monitoring during intense physical activities. PMID:26703618
Salehizadeh, Seyed M A; Dao, Duy; Bolkhovsky, Jeffrey; Cho, Chae; Mendelson, Yitzhak; Chon, Ki H
2015-12-23
Accurate estimation of heart rates from photoplethysmogram (PPG) signals during intense physical activity is a very challenging problem. This is because strenuous and high intensity exercise can result in severe motion artifacts in PPG signals, making accurate heart rate (HR) estimation difficult. In this study we investigated a novel technique to accurately reconstruct motion-corrupted PPG signals and HR based on time-varying spectral analysis. The algorithm is called Spectral filter algorithm for Motion Artifacts and heart rate reconstruction (SpaMA). The idea is to calculate the power spectral density of both PPG and accelerometer signals for each time shift of a windowed data segment. By comparing time-varying spectra of PPG and accelerometer data, those frequency peaks resulting from motion artifacts can be distinguished from the PPG spectrum. The SpaMA approach was applied to three different datasets and four types of activities: (1) training datasets from the 2015 IEEE Signal Process. Cup Database recorded from 12 subjects while performing treadmill exercise from 1 km/h to 15 km/h; (2) test datasets from the 2015 IEEE Signal Process. Cup Database recorded from 11 subjects while performing forearm and upper arm exercise. (3) Chon Lab dataset including 10 min recordings from 10 subjects during treadmill exercise. The ECG signals from all three datasets provided the reference HRs which were used to determine the accuracy of our SpaMA algorithm. The performance of the SpaMA approach was calculated by computing the mean absolute error between the estimated HR from the PPG and the reference HR from the ECG. The average estimation errors using our method on the first, second and third datasets are 0.89, 1.93 and 1.38 beats/min respectively, while the overall error on all 33 subjects is 1.86 beats/min and the performance on only treadmill experiment datasets (22 subjects) is 1.11 beats/min. Moreover, it was found that dynamics of heart rate variability can be accurately captured using the algorithm where the mean Pearson's correlation coefficient between the power spectral densities of the reference and the reconstructed heart rate time series was found to be 0.98. These results show that the SpaMA method has a potential for PPG-based HR monitoring in wearable devices for fitness tracking and health monitoring during intense physical activities.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-06
... DEPARTMENT OF TRANSPORTATION Surface Transportation Board [Docket No. NOR 42129; Docket No. FD 35517] American Chemistry Council, The Chlorine Institute, Inc., the Fertilizer Institute, and PPG... both cases. \\1\\ In Docket No. NOR 42129, the complainants are American Chemistry Council, The Chlorine...
Heating Efficiency of Beat Wave Excitation in a Density Gradient,
1988-02-01
and Technology, January 1988. PPG-1124 Research Highlights in The Pisces Program," R.V. Conn, et al, January 1988. PPG-1125 "Magnetic Fusion ... Energy , vol. 5. Technical Assessement of Critical Issues in the Steady State Operation of Fusion Confinement Devices," D. M. Goebel, Assessment Chairman
Multispectral, Fluorescent and Photoplethysmographic Imaging for Remote Skin Assessment
Spigulis, Janis
2017-01-01
Optical tissue imaging has several advantages over the routine clinical imaging methods, including non-invasiveness (it does not change the structure of tissues), remote operation (it avoids infections) and the ability to quantify the tissue condition by means of specific image parameters. Dermatologists and other skin experts need compact (preferably pocket-size), self-sustaining and easy-to-use imaging devices. The operational principles and designs of ten portable in-vivo skin imaging prototypes developed at the Biophotonics Laboratory of Institute of Atomic Physics and Spectroscopy, University of Latvia during the recent five years are presented in this paper. Four groups of imaging devices are considered. Multi-spectral imagers offer possibilities for distant mapping of specific skin parameters, thus facilitating better diagnostics of skin malformations. Autofluorescence intensity and photobleaching rate imagers show a promising potential for skin tumor identification and margin delineation. Photoplethysmography video-imagers ensure remote detection of cutaneous blood pulsations and can provide real-time information on cardiovascular parameters and anesthesia efficiency. Multimodal skin imagers perform several of the abovementioned functions by taking a number of spectral and video images with the same image sensor. Design details of the developed prototypes and results of clinical tests illustrating their functionality are presented and discussed. PMID:28534815
Behm, Kevin; Larson, David W.; Colibaseanu, Dorin
2015-01-01
Peristomal pyoderma gangrenosum (PPG) is a rare subtype of pyoderma gangrenosum that is characterized by painful, necrotic ulcerations occurring in the area surrounding an abdominal stoma. PPG is typically seen in younger patients with active inflammatory bowel disease. The etiology and pathogenesis is largely unknown and risk factors are not well defined. Therapy typically involves a combination of aggressive local wound care and systemic medications. Diagnosis and management of PPG can be difficult and data on treatment are limited. We present a case of severe postoperative peristomal recalcitrant to conventional therapy successfully treated with intravenous immune globulin. PMID:25802252
Design of an Oximeter Based on LED-LED Configuration and FPGA Technology
Stojanovic, Radovan; Karadaglic, Dejan
2013-01-01
A fully digital photoplethysmographic (PPG) sensor and actuator has been developed. The sensing circuit uses one Light Emitting Diode (LED) for emitting light into human tissue and one LED for detecting the reflectance light from human tissue. A Field Programmable Gate Array (FPGA) is used to control the LEDs and determine the PPG and Blood Oxygen Saturation (SpO2). The configurations with two LEDs and four LEDs are developed for measuring PPG signal and Blood Oxygen Saturation (SpO2). N-LEDs configuration is proposed for multichannel SpO2 measurements. The approach resulted in better spectral sensitivity, increased and adjustable resolution, reduced noise, small size, low cost and low power consumption. PMID:23291575
Poh, Ming-Zher; Poh, Yukkee C
2017-08-01
The aim of this study was to determine the accuracy of a freely available smartphone application, Cardiio app (Cardiio, Inc., Cambridge, MA), to measure heart rate from the finger or face using imaging photoplethysmography, by comparing against an FDA-cleared pulse oximeter at rest, and after moderate to vigorous exercise. A total of 40 healthy adults participated in this study. Participants engaged in a period of rest, followed by 3 min of moderate to vigorous intensity cycling on a stationary bicycle. Heart rate measurements were obtained from both the finger and face of participants using the Cardiio app at rest, immediately after exercise, 1-2 min after exercise, and 2-3 min after exercise. Concurrent heart rate readings using an FDA-cleared finger pulse oximeter served as the reference measurement. There was a very strong agreement between heart rate measurements obtained using the Cardiio app and the pulse oximeter, both at rest (r = 0.99 for finger, r = 0.97 for face) and after exercise (r = 0.99 for finger, r = 0.97 for face). At rest, the accuracy of the Cardiio app was ±1.58 beats per minute (bpm) (or ±2.27%) using the finger mode and ±2.28 bpm (or ±3.17%) for the face mode, compared to the pulse oximeter. After moderate to vigorous exercise, the accuracy of the Cardiio app was ±2.97 bpm (or ±2.79%) using the finger mode and ±5.31 bpm (or ±4.50%) for the face mode, compared to the pulse oximeter. The Cardiio app provided accurate heart rate measurements from the finger and face, both at rest and after exercise.
Marschall-Lévesque, Shawn; Rouleau, Joanne-Lucine; Renaud, Patrice
2018-02-01
Penile plethysmography (PPG) is a measure of sexual interests that relies heavily on the stimuli it uses to generate valid results. Ethical considerations surrounding the use of real images in PPG have further limited the content admissible for these stimuli. To palliate this limitation, the current study aimed to combine audio and visual stimuli by incorporating computer-generated characters to create new stimuli capable of accurately classifying sex offenders with child victims, while also increasing the number of valid profiles. Three modalities (audio, visual, and audiovisual) were compared using two groups (15 sex offenders with child victims and 15 non-offenders). Both the new visual and audiovisual stimuli resulted in a 13% increase in the number of valid profiles at 2.5 mm, when compared to the standard audio stimuli. Furthermore, the new audiovisual stimuli generated a 34% increase in penile responses. All three modalities were able to discriminate between the two groups by their responses to the adult and child stimuli. Lastly, sexual interest indices for all three modalities could accurately classify participants in their appropriate groups, as demonstrated by ROC curve analysis (i.e., audio AUC = .81, 95% CI [.60, 1.00]; visual AUC = .84, 95% CI [.66, 1.00], and audiovisual AUC = .83, 95% CI [.63, 1.00]). Results suggest that computer-generated characters allow accurate discrimination of sex offenders with child victims and can be added to already validated stimuli to increase the number of valid profiles. The implications of audiovisual stimuli using computer-generated characters and their possible use in PPG evaluations are also discussed.
Hazardous Waste Cleanup: PPG Industries Caribe in Guayanilla, Puerto Rico
The PPG Industries Caribe Site is located on the south coast of Puerto Rico at the mouth of the Macaná River at the northeast coast of Guayanilla Bay. The village of La Playa de Guanilla lies about 0.5 mile south and southwest of the Site. The Site occupie
Acute activation of GLP-1-expressing neurons promotes glucose homeostasis and insulin sensitivity
USDA-ARS?s Scientific Manuscript database
Glucagon-like peptides are co-released from enteroendocrine L cells in the gut and preproglucagon (PPG) neurons in the Brainstem. PPG-derived GLP-1/2 are probably key neuroendocrine signals for the control of energy balance and glucose Homeostasis. The objective of this study was to determine whethe...
On Time Domain Analysis of Photoplethysmogram Signals for Monitoring Heat Stress
Elgendi, Mohamed; Fletcher, Rich; Norton, Ian; Brearley, Matt; Abbott, Derek; Lovell, Nigel H.; Schuurmans, Dale
2015-01-01
There are a limited number of studies on heat stress dynamics during exercise using the photoplethysmogram (PPG) and its second derivative (APG). However, we investigate the most suitable index from short PPG signal recordings for heat stress assessment. The APG waveform consists of a, b, c and d waves in systole and an e wave in diastole. Our preliminary results indicate that the use of the energy of aa area, derived from PPG signals measured from emergency responders in tropical conditions, is promising in determining the heat stress level using 20-s recordings. After examining 14 time domain features using leave-one-out cross-validation, we found that the aa energy extracted from PPG signals is the most informative feature for classifying heat-stressed subjects, with an overall accuracy of 79%. Moreover, the combination of the aa energy with the traditional heart rate variability index of heat stress (i.e., the square root of the mean of the squares of the successive aa intervals) improved the heat stress detection to an overall accuracy of 83%. PMID:26404271
On Time Domain Analysis of Photoplethysmogram Signals for Monitoring Heat Stress.
Elgendi, Mohamed; Fletcher, Rich; Norton, Ian; Brearley, Matt; Abbott, Derek; Lovell, Nigel H; Schuurmans, Dale
2015-09-25
There are a limited number of studies on heat stress dynamics during exercise using the photoplethysmogram (PPG) and its second derivative (APG). However, we investigate the most suitable index from short PPG signal recordings for heat stress assessment. The APG waveform consists of a, b, c and d waves in systole and an e wave in diastole. Our preliminary results indicate that the use of the energy of aa area, derived from PPG signals measured from emergency responders in tropical conditions, is promising in determining the heat stress level using 20-s recordings. After examining 14 time domain features using leave-one-out cross-validation, we found that the aa energy extracted from PPG signals is the most informative feature for classifying heat-stressed subjects, with an overall accuracy of 79%. Moreover, the combination of the aa energy with the traditional Sensors 2015, 15 24717 heart rate variability index of heat stress (i.e., the square root of the mean of the squares of the successive aa intervals) improved the heat stress detection to an overall accuracy of 83%.
Neural network for photoplethysmographic respiratory rate monitoring
NASA Astrophysics Data System (ADS)
Johansson, Anders
2001-10-01
The photoplethysmographic signal (PPG) includes respiratory components seen as frequency modulation of the heart rate (respiratory sinus arrhythmia, RSA), amplitude modulation of the cardiac pulse, and respiratory induced intensity variations (RIIV) in the PPG baseline. The aim of this study was to evaluate the accuracy of these components in determining respiratory rate, and to combine the components in a neural network for improved accuracy. The primary goal is to design a PPG ventilation monitoring system. PPG signals were recorded from 15 healthy subjects. From these signals, the systolic waveform, diastolic waveform, respiratory sinus arrhythmia, pulse amplitude and RIIV were extracted. By using simple algorithms, the rates of false positive and false negative detection of breaths were calculated for each of the five components in a separate analysis. Furthermore, a simple neural network (NN) was tried out in a combined pattern recognition approach. In the separate analysis, the error rates (sum of false positives and false negatives) ranged from 9.7% (pulse amplitude) to 14.5% (systolic waveform). The corresponding value of the NN analysis was 9.5-9.6%.
2014-10-01
a period of time by electrodes attached to the surface of the skin, are used in almost every clinical environment. Pulse oximeters , which measure the...medical devices, for example, pulse oximeters , vascular diagnostics, and digital beat-to-beat blood pressure measurement systems (Allen 2007). PPG is...principle is pulse oximetry. 1.2 Pulse Oximetry A pulse oximeter monitors the blood-oxygen saturation level and pulse rate in the human blood by using
Accidents and injuries related to powered paragliding: a cross-sectional study
Feletti, Francesco; Goin, Jeff
2014-01-01
Objectives Powered paragliding (PPG) and paragliding are two totally different sports, mainly because of the use of an engine in powered paragliding. As a consequence, the pattern of injuries caused by each of these two sports may be different. Setting To test this hypothesis, we analysed 384 incident reports gathered by the US Powered Paragliding Association from 1995 to 2012. The majority of the incidents occurred in the USA, while 26 incidents occurred elsewhere: Canada (8), Mexico (5), Panama (1), China (1), Japan (1), Malaysia (1), Indonesia (Java) (1), Europe (8): of which Spain (1), Belgium (1), UK (3), Italy (1), Romania (1), unknown (1). Outcome To identify the most affected body area and the most common type of injury sustained in PPG, and to highlight any differences from paragliding. Results The most affected body areas in PPG were the upper limbs (44.5%), followed by the lower limbs (32%), the back (9.8%), the head (7%), the pelvis (3.1), the chest (2.7%) and the abdomen (0.7%) (p<0.001). The engine caused 43 accidents (11.2%) in our study and was responsible for the majority of injuries to the upper limbs. The number of fatal accidents in PPG is not lower than in paragliding and hang-gliding. Conclusions To help prevent the specific injuries of PPG, the most appropriate equipment should be identified. The results of this study also suggest that, in the future, this sport should be analysed separately from paragliding. PMID:25168039
Respiratory rate estimation during triage of children in hospitals.
Shah, Syed Ahmar; Fleming, Susannah; Thompson, Matthew; Tarassenko, Lionel
2015-01-01
Accurate assessment of a child's health is critical for appropriate allocation of medical resources and timely delivery of healthcare in Emergency Departments. The accurate measurement of vital signs is a key step in the determination of the severity of illness and respiratory rate is currently the most difficult vital sign to measure accurately. Several previous studies have attempted to extract respiratory rate from photoplethysmogram (PPG) recordings. However, the majority have been conducted in controlled settings using PPG recordings from healthy subjects. In many studies, manual selection of clean sections of PPG recordings was undertaken before assessing the accuracy of the signal processing algorithms developed. Such selection procedures are not appropriate in clinical settings. A major limitation of AR modelling, previously applied to respiratory rate estimation, is an appropriate selection of model order. This study developed a novel algorithm that automatically estimates respiratory rate from a median spectrum constructed applying multiple AR models to processed PPG segments acquired with pulse oximetry using a finger probe. Good-quality sections were identified using a dynamic template-matching technique to assess PPG signal quality. The algorithm was validated on 205 children presenting to the Emergency Department at the John Radcliffe Hospital, Oxford, UK, with reference respiratory rates up to 50 breaths per minute estimated by paediatric nurses. At the time of writing, the authors are not aware of any other study that has validated respiratory rate estimation using data collected from over 200 children in hospitals during routine triage.
Little, Jonathan P; Jung, Mary E; Wright, Amy E; Wright, Wendi; Manders, Ralph J F
2014-07-01
The purpose of this study was to examine the impact of acute high-intensity interval training (HIIT) compared with continuous moderate-intensity (CMI) exercise on postprandial hyperglycemia in overweight or obese adults. Ten inactive, overweight or obese adults (41 ± 11 yrs, BMI = 36 ± 7 kg/m(2)) performed an acute bout of HIIT (10 × 1 min at approximately 90% peak heart rate (HRpeak) with 1-min recovery periods) or matched work CMI (30 min at approximately 65% HRpeak) in a randomized, counterbalanced fashion. Exercise was performed 2 h after breakfast, and glucose control was assessed by continuous glucose monitoring under standardized dietary conditions over 24 h. Postprandial glucose (PPG) responses to lunch, dinner, and the following day's breakfast were analyzed and compared with a no-exercise control day. Exercise did not affect the PPG responses to lunch, but performing both HIIT and CMI in the morning significantly reduced the PPG incremental area under the curve (AUC) following dinner when compared with control (HIIT = 110 ± 35, CMI = 125 ± 34, control = 162 ± 46 mmol/L × 2 h, p < 0.05). The PPG AUC (HIIT = 125 ± 53, CMI = 186 ± 55, control = 194 ± 96 mmol/L × 2 h) and the PPG spike (HIIT = Δ2.1 ± 0.9, CMI = Δ3.0 ± 0.9, control = Δ3.0 ± 1.5 mmol/l) following breakfast on the following day were significantly lower following HIIT compared with both CMI and control (p < 0.05). Absolute AUC and absolute glucose spikes were not different between HIIT, CMI, or control for any meal (p > 0.05 for all). We conclude that a single session of HIIT has greater and more lasting effects on reducing incremental PPG when compared with CMI.
Charlton, Peter H; Bonnici, Timothy; Tarassenko, Lionel; Clifton, David A; Beale, Richard; Watkinson, Peter J
2016-04-01
Over 100 algorithms have been proposed to estimate respiratory rate (RR) from the electrocardiogram (ECG) and photoplethysmogram (PPG). As they have never been compared systematically it is unclear which algorithm performs the best. Our primary aim was to determine how closely algorithms agreed with a gold standard RR measure when operating under ideal conditions. Secondary aims were: (i) to compare algorithm performance with IP, the clinical standard for continuous respiratory rate measurement in spontaneously breathing patients; (ii) to compare algorithm performance when using ECG and PPG; and (iii) to provide a toolbox of algorithms and data to allow future researchers to conduct reproducible comparisons of algorithms. Algorithms were divided into three stages: extraction of respiratory signals, estimation of RR, and fusion of estimates. Several interchangeable techniques were implemented for each stage. Algorithms were assembled using all possible combinations of techniques, many of which were novel. After verification on simulated data, algorithms were tested on data from healthy participants. RRs derived from ECG, PPG and IP were compared to reference RRs obtained using a nasal-oral pressure sensor using the limits of agreement (LOA) technique. 314 algorithms were assessed. Of these, 270 could operate on either ECG or PPG, and 44 on only ECG. The best algorithm had 95% LOAs of -4.7 to 4.7 bpm and a bias of 0.0 bpm when using the ECG, and -5.1 to 7.2 bpm and 1.0 bpm when using PPG. IP had 95% LOAs of -5.6 to 5.2 bpm and a bias of -0.2 bpm. Four algorithms operating on ECG performed better than IP. All high-performing algorithms consisted of novel combinations of time domain RR estimation and modulation fusion techniques. Algorithms performed better when using ECG than PPG. The toolbox of algorithms and data used in this study are publicly available.
Charlton, Peter H; Bonnici, Timothy; Tarassenko, Lionel; Clifton, David A; Beale, Richard; Watkinson, Peter J
2016-01-01
Abstract Over 100 algorithms have been proposed to estimate respiratory rate (RR) from the electrocardiogram (ECG) and photoplethysmogram (PPG). As they have never been compared systematically it is unclear which algorithm performs the best. Our primary aim was to determine how closely algorithms agreed with a gold standard RR measure when operating under ideal conditions. Secondary aims were: (i) to compare algorithm performance with IP, the clinical standard for continuous respiratory rate measurement in spontaneously breathing patients; (ii) to compare algorithm performance when using ECG and PPG; and (iii) to provide a toolbox of algorithms and data to allow future researchers to conduct reproducible comparisons of algorithms. Algorithms were divided into three stages: extraction of respiratory signals, estimation of RR, and fusion of estimates. Several interchangeable techniques were implemented for each stage. Algorithms were assembled using all possible combinations of techniques, many of which were novel. After verification on simulated data, algorithms were tested on data from healthy participants. RRs derived from ECG, PPG and IP were compared to reference RRs obtained using a nasal-oral pressure sensor using the limits of agreement (LOA) technique. 314 algorithms were assessed. Of these, 270 could operate on either ECG or PPG, and 44 on only ECG. The best algorithm had 95% LOAs of −4.7 to 4.7 bpm and a bias of 0.0 bpm when using the ECG, and −5.1 to 7.2 bpm and 1.0 bpm when using PPG. IP had 95% LOAs of −5.6 to 5.2 bpm and a bias of −0.2 bpm. Four algorithms operating on ECG performed better than IP. All high-performing algorithms consisted of novel combinations of time domain RR estimation and modulation fusion techniques. Algorithms performed better when using ECG than PPG. The toolbox of algorithms and data used in this study are publicly available. PMID:27027672
Gao, Jing; Zheng, Xiao; Zheng, Yuan-Yi; Zuo, Guo-Qing; Ran, Hai-Tao; Auh, Yong Ho; Waldron, Levi; Chan, Tiffany; Wang, Zhi-Gang
2016-05-01
To assess the feasibility of splenic shear wave elastography in monitoring transjugular intrahepatic portosystemic shunt (TIPS) function. We measured splenic shear wave velocity (SWV), main portal vein velocity (PVV), and splenic vein velocity (SVV) in 33 patients 1 day before and 3 days to 12 months after TIPS placement. We also measured PVV, SVV, and SWV in 10 of 33 patients with TIPS dysfunction 1 day before and 3 to 6 days after TIPS revision. Analyses included differences in portosystemic pressure gradient (PPG), PVV, SVV, and mean SWV before and after TIPS procedures; comparison of median SWV before and after TIPS procedures; differences in PVV, SVV, and SWV before and at different times up to 12 months after TIPS placement; accuracy of PVV, SVV, and SWV in determining TIPS dysfunction; and correlation between PPG and SWV. During 12 months of follow-up, 23 of 33 patients had functioning TIPS, and 10 had TIPS dysfunction. The median SWV was significantly different before and after primary TIPS placement (3.60 versus 3.05 m/s; P = .005), as well as before and after revision (3.73 versus 3.06 m/s; P = .003). The PPG, PVV, and SVV were also significantly different before and after TIPS placement and revision (P < .001). The PPG and SWV decreased, whereas PVV and SVV increased, after successful TIPS procedures. A positive correlation was observed between PPG and SWV (r = 0.70; P < .001), and a negative correlation was observed between PPG and PVV and SVV (r = -0.65; P < .001). The areas under the receiver operating characteristic curve for PVV, SVV, and SWV in determining TIPS dysfunction were 0.82, 0.84, and 0.81, respectively. Splenic SWV is compatible with splenoportal venous velocity in quantitatively monitoring TIPS function and determining TIPS dysfunction. © 2016 by the American Institute of Ultrasound in Medicine.
Sheu, Wayne H-H; Brunell, Steven C; Blase, Erich
2016-04-01
The efficacy and safety of exenatide twice daily (BID) and once weekly (QW) were assessed in Asian versus White patients with type 2 diabetes mellitus (T2DM). This post-hoc pooled analysis evaluated patients receiving 10μg exenatide BID for 12-30 weeks or 2mg exenatide QW for 24-30 weeks in exenatide clinical development program trials. Race was self-identified. A total of 4625 patients were included (exenatide BID: Asian, n=787; White, n=2223; exenatide QW: Asian, n=511; White, n=1104). At study end, glycated hemoglobin (HbA1c), fasting glucose (FG), body weight, post-prandial glucose (PPG), and PPG excursions were significantly reduced (all P<0.0001 vs baseline). For exenatide BID, HbA1c reduction was greater in Asians (P<0.0001 vs Whites), whereas HbA1c reduction did not differ by race for exenatide QW. FG reduction did not differ by race for either exenatide formulation. Weight reduction was significantly greater in Whites (P<0.0001 vs Asians), regardless of exenatide formulation. PPG reduction was greater in Asians (P<0.0001 vs Whites) for exenatide BID but did not differ by race for exenatide QW. For exenatide BID, reductions in PPG excursions for all meals were significantly greater in Asians (P<0.0001 vs Whites), whereas only post-breakfast and post-lunch excursions were significantly greater in Asians for exenatide QW (P=0.0009 and P=0.0189 vs Whites, respectively). Common adverse events included nausea, headache, and diarrhea. Exenatide BID and QW improved glycemic control, including PPG, in Asian and White patients with T2DM. With exenatide BID, Asian patients exhibited significantly greater reductions in HbA1c and PPG than White patients. Both exenatide formulations were well tolerated in both groups. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
Peter, R; Dunseath, G; Luzio, S D; Owens, D R
2013-09-01
To re-examine the relative and absolute contributions of fasting/pre-prandial glucose (FPG) and post-prandial glucose (PPG) to 24-h hyperglycaemia and HbA1c respectively in non-insulin treated subjects with type 2 diabetes (T2DM). A total of 52 T2DM subjects (37 men) had daytime 12h plasma glucose (PG) profiles determined in response to three serial identical test meals commencing at 08 00h with pre-prandial and frequent post-prandial blood samples collected. The overnight PG profile was derived by projecting the 20 00h glucose concentration to the pre-breakfast value at 08 00h. PPG exposure was calculated above fasting/pre-prandial value for each meal. Excess hyperglycaemia was calculated based on a PG>5.5mmol/L with fasting hyperglycaemia being the difference between the two measurements. The subjects were divided into five groups according to the HbA1c (Group 1<7.0%; Group 2: 7.0-<7.5; Group 3: 7.5-<8.0%; Group 4: 8.0-<9.0%; Group 5:≥9.0%). The 24h relative contribution of PPG exposure and fasting hyperglycaemia to excess hyperglycaemia and the absolute contribution of PPG and fasting hyperglycaemia to excess HbA1c (HbA1c - 5.1%) was calculated. With deteriorating glycaemia, the relative contribution of PPG exposure decreased across the groups from 43.5% (HbA1c<7.0%) to 17.8% (HbA1c≥9.0%), whilst the contributions of fasting hyperglycaemia increased from 56.5% to 82.2% (P=0.004), respectively. The absolute contributions of PPG to excess HbA1c was 0.7%, which remained relatively stable across the spectrum of HbA1c, whilst fasting hyperglycaemia increased significantly from groups 1 to 5 (P<0.001). Fasting hyperglycaemia contributes substantially in all groups, increasing as HbA1c deteriorates. The absolute contribution of PPG to excess HbA1c did not vary across the range of HbA1c, representing a significant relative contribution even in well-controlled subjects with a HbA1c<7.0%. Copyright © 2013. Published by Elsevier Masson SAS.
Investigation on micro-patterned gold-plated polymer substrate for a micro hydraulic actuator
NASA Astrophysics Data System (ADS)
Sundaresan, Vishnu Baba; Akle, Barbar; Leo, Donald J.
2006-03-01
Plants have the ability to develop large mechanical force from chemical energy available with bio-fuels. The energy released by the cleavage of a terminal phosphate ion during the hydrolysis of a bio-fuel assists the transport of ions and fluids in cellular homeostasis. Materials that develop pressure and hence strain similar to the response of plants to an external stimuli are classified as nastic materials. This new class of actuators use protein transporters as functional units to move species and result in deformation [Leo et al 2005 (Proceedings of IMECE - 06)]. The ion transporters are hydrocarbons which are formed across the cellular membranes. The membranes that house the ion transporters are aggregates of phospholipids rigidized by cytoskeleton. Reconstituting these nano-machines on a harder matrix is quintessential to build a functional device. Artificial phospholipid membranes or Biliayer lipid membranes (BLM) have poor structural integrity and do not adhere to most surfaces. Patterned arrays of pores made on Poly-propylene glycol-diacrylate (PPG-DA) substrate, a photo curable polymer was made available to us for initial design iterations for an actuator. Hydrophobicity of PPG-DA posed initial problems to support a BLM. We modified the surface of micropatterned PPG-DA membrane by gold plating it. The surface of the porous PPG-DA membranes was plated with gold (Au). A 10nm seeding layer of Au was sputtered on the surface of the membrane. Further gold was reduced onto the sputtered gold surface [Supriya et al(Langmuir 2004, 20, 8870-8876)] by suspending the samples in a solution of hydroxylamine and Hydrogen tetrachloroaurate(III) trihydrate [HAuCl4.3H2O]. This reduction process increased the thickness of the gold, enhanced its adhesion to the PPG-DA substrate and improved the shapes of the pores. This surface modification of PPG-DA helped us form stable BLM with 1-Palmitoyl-2-Oleoyl-sn-Glycero-3- [Phospho-L-Serine] (Sodium Salt) (POPS), 1-Palmitoyl-2-Oleoyl-sn-Glycero- 3-Phosphoethanolamine (POPE) lipids. The observed ionic resistance of the BLM remained stable and sustained 4 mm water column for the the four hours observation period. This article describes the procedure we adopted to modify the PPG-DA substrate, form a BLM and the procedure to quantify the stability of the BLM formed with -amine and -thiol head groups in the lipids.
Optimal wavelength selection for noncontact reflection photoplethysmography
NASA Astrophysics Data System (ADS)
Corral Martinez, Luis F.; Paez, Gonzalo; Strojnik, Marija
2011-08-01
In this work, we obtain backscattered signals from human forehead for wavelengths from 380 to 980 nm. The results reveal bands with strong pulsatile signals that carry useful information. We describe those bands as the most suitable wavelengths in the visible and NIR regions from which heart and respiratory rate parameters can be derived using long distance non-contact reflection photoplethysmography analysis. The latter results show the feasibility of a novel technique for remotely detection of vital signs in humans. This technique, which may include morphological analysis or maps of tissue oxygenation, is a further step to real non-invasive remote monitoring of patients.
Using the Item Response Theory (IRT) for Educational Evaluation through Games
ERIC Educational Resources Information Center
Euzébio Batista, Marcelo Henrique; Victória Barbosa, Jorge Luis; da Rosa Tavares, João Elison; Hackenhaar, Jonathan Luis
2013-01-01
This article shows the application of Item Response Theory (IRT) for educational evaluation using games. The article proposes a computational model to create user profiles, called Psychometric Profile Generator (PPG). PPG uses the IRT mathematical model for exploring the levels of skills and behaviors in the form of items and/or stimuli. The model…
Modeling of Nonlinear Dynamics of a Powered Paraglider
NASA Astrophysics Data System (ADS)
Watanabe, Masahito; Ochi, Yoshimasa
This paper presents a nonlinear dynamic model of a powered paraglider (PPG). The PPG is composed of a canopy and a payload with a propelling unit. The canopy is connected with the payload at two points. The model has been derived as a state vector equation under the assumption that the canopy has six degrees of freedom (DOF) and the payload has two DOF of pitching and yawing motions relative to the canopy. Friction at the connecting points between the canopy and the payload is taken into account. Time responses of the PPG without thrust have been computed using the model and the results are compared with flight experiment data. Simulation of a level flight with thrust has also been conducted.
Ye, Jing-Jhao; Lee, Kuan-Ting; Lin, Jing-Siang; Chuang, Chiung-Cheng
2017-01-01
Continuously monitoring and efficiently managing pain has become an important issue. However, no study has investigated a change in physiological parameters during the process of pain production/relief. This study modeled the process of pain production/relief using ramped thermal stimulation (no pain: 37°C water, process of pain production: a heating rate of 1°C/min, and subject feels pain: water kept at the painful temperature for each subject, with each segment lasting 10 min). In this duration, the variation of the heat rate variability and photoplethysmography-derived parameters was observed. A total of 40 healthy individuals participated: 30 in the trial group (14 males and 16 females with a mean age of 22.5±1.9 years) and 10 in the control group (7 males and 3 females with a mean age of 22.5±1.3 years). The results showed that the numeric rating scale value was 5.03±1.99 when the subjects felt pain, with a temperature of 43.54±1.70°C. Heart rate, R-R interval, low frequency, high frequency, photoplethysmography amplitude, baseline, and autonomic nervous system state showed significant changes during the pain production process, but these changes differed during the period Segment D (painful temperature 10: min). In summary, the study observed that physiological parameters changed qualitatively during the process of pain production and relief and found that the high frequency, low frequency, and photoplethysmography parameters seemed to have different responses in four situations (no pain, pain production, pain experienced, and pain relief). The trends of these variations may be used as references in the clinical setting for continuously observing pain intensity.
Inra, Jennifer A; Nayor, Jennifer; Rosenblatt, Margery; Mutinga, Muthoka; Reddy, Sarathchandra I; Syngal, Sapna; Kastrinos, Fay
2017-04-01
Quality performance measures for screening colonoscopy vary among endoscopists. The impact of practice setting is unknown. We aimed to (1) compare screening colonoscopy performance measures among three different US practice settings; (2) evaluate factors associated with adenoma detection; and (3) assess a scorecard intervention on performance metrics. This multi-center prospective study compared patient, endoscopist, and colonoscopy characteristics performed at a tertiary care hospital (TCH), community-based hospital (CBH), and private practice group (PPG). Withdrawal times (WT), cecal intubation, and adenoma detection rates (ADR) were compared by site at baseline and 12 weeks following scorecard distribution. Generalized linear mixed models identified factors associated with adenoma detection. Twenty-eight endoscopists performed colonoscopies on 1987 asymptomatic, average-risk individuals ≥50 years. Endoscopist and patient characteristics were similar across sites. The PPG screened more men (TCH: 42.8%, CBH: 45.0%, PPG: 54.2%; p < 0.0001). Preparation quality varied with good/excellent results in 70.6, 88.3, and 92% of TCH, CBH, and PPG cases, respectively (p < 0.0001). Male ADRs, cecal intubation, and WT exceeded recommended benchmarks despite variable results at each site; female ADRs were <15% at the PPG which screened the fewest females. Performance remained unchanged following scorecard distribution. Adenoma detection was associated with increasing patient age, male gender, WT, adequate preparation, but not practice setting. Each practice performed high-quality screening colonoscopy. Scorecards did not improve performance metrics. Preparation quality varies among practice settings and can be modified to improve adenoma detection.
Boers, Hanny M; MacAulay, Katrina; Murray, Peter; Dobriyal, Rajendra; Mela, David J; Spreeuwenberg, Maria A M
2017-02-01
The incidence of type 2 diabetes mellitus (T2DM) is increasing worldwide, including in developing countries, particularly in South Asia. Intakes of foods generating a high postprandial glucose (PPG) response have been positively associated with T2DM. As part of efforts to identify effective and feasible strategies to reduce the glycaemic impact of carbohydrate-rich staples, we previously found that addition of guar gum (GG) and chickpea flour (CPF) to wheat flour could significantly reduce the PPG response to flatbread products. On the basis of the results of an exploratory study with Caucasian subjects, we have now tested the effect of additions of specific combinations of CPF with low doses of GG to a flatbread flour mix for their impacts on PPG and postprandial insulin (PPI) responses in a South-Asian population. In a randomised, placebo-controlled full-cross-over design, fifty-six healthy Indian adults consumed flatbreads made with a commercial flatbread mix (100 % wheat flour) with no further additions (control) or incorporating 15 % CPF in combination with 2, 3 or 4 % GG. The flatbreads with CPF and 3 or 4 % GG significantly reduced PPG (both ≥15 % reduction in positive incremental AUC, P<0·01) and PPI (both ≥28 % reduction in total AUC, P<0·0001) compared with flatbreads made from control flour. These results confirm the efficacy and feasibility of the addition of CPF with GG to flatbread flour mixes to achieve significant reductions in both PPG and PPI in Indian subjects.
NASA Astrophysics Data System (ADS)
Qian, Zhengyang; Takezawa, Yoshiki; Shimokawa, Kenji; Kino, Hisashi; Fukushima, Takafumi; Kiyoyama, Koji; Tanaka, Tetsu
2018-04-01
Health monitoring and self-management have become increasingly more important because of health awareness improvement, the aging of population, and other reasons. In general, pulse waves are among the most useful physiological signals that can be used to calculate several parameters such as heart rate and blood pressure for health monitoring and self-management. To realize an automatic and real-time pulse-wave monitoring system that can be used in daily life, we have proposed a trans-nail pulse-wave monitoring system that was placed on the fingernail to detect photoplethysmographic (PPG) signals as pulse waves. In this study, we designed a PPG recording circuit that was composed of a 600 × 600 µm2 photodiode (PD), an LED driver with pulse wave modulation (PWM) and a low-frequency ring oscillator (RING), and a PPG signal readout circuit. The proposed circuit had a very small area of 2.2 × 1.1 mm2 designed with 0.18 µm CMOS technology. The proposed circuit was used to detect pulse waves on the human fingernail in both the reflection and transmission modes. Electrical characteristics of the prototype system were evaluated precisely and PPG waveforms were obtained successfully.
Using eye tracking to identify faking attempts during penile plethysmography assessment.
Trottier, Dominique; Rouleau, Joanne-Lucine; Renaud, Patrice; Goyette, Mathieu
2014-01-01
Penile plethysmography (PPG) is considered the most rigorous method for sexual interest assessment. Nevertheless, it is subject to faking attempts by participants, which compromises the internal validity of the instrument. To date, various attempts have been made to limit voluntary control of sexual response during PPG assessments, without satisfactory results. This exploratory research examined eye-tracking technologies' ability to identify the presence of cognitive strategies responsible for erectile inhibition during PPG assessment. Eye movements and penile responses for 20 subjects were recorded while exploring animated human-like computer-generated stimuli in a virtual environment under three distinct viewing conditions: (a) the free visual exploration of a preferred sexual stimulus without erectile inhibition; (b) the viewing of a preferred sexual stimulus with erectile inhibition; and (c) the free visual exploration of a non-preferred sexual stimulus. Results suggest that attempts to control erectile responses generate specific eye-movement variations, characterized by a general deceleration of the exploration process and limited exploration of the erogenous zone. Findings indicate that recording eye movements can provide significant information on the presence of competing covert processes responsible for erectile inhibition. The use of eye-tracking technologies during PPG could therefore lead to improved internal validity of the plethysmographic procedure.
Effect of exercise timing on elevated postprandial glucose levels.
Hatamoto, Yoichi; Goya, Ryoma; Yamada, Yosuke; Yoshimura, Eichi; Nishimura, Sena; Higaki, Yasuki; Tanaka, Hiroaki
2017-08-01
There is no consensus regarding optimal exercise timing for reducing postprandial glucose (PPG). The purpose of the present study was to determine the most effective exercise timing. Eleven participants completed four different exercise patterns 1 ) no exercise; 2 ) preprandial exercise (jogging); 3 ) postprandial exercise; and 4 ) brief periodic exercise intervention (three sets of 1-min jogging + 30 s of rest, every 30 min, 20 times total) in a random order separated by a minimum of 5 days. Preprandial and postprandial exercise consisted of 20 sets of intermittent exercise (1 min of jogging + 30 s rest per set) repeated 3 times per day. Total daily exercise volume was identical for all three exercise patterns. Exercise intensities were 62.4 ± 12.9% V̇o 2peak Blood glucose concentrations were measured continuously throughout each trial for 24 h. After breakfast, peak blood glucose concentrations were lower with brief periodic exercise (99 ± 6 mg/dl) than those with preprandial and postprandial exercise (109 ± 10 and 115 ± 14 mg/dl, respectively, P < 0.05, effect size = 0.517). After lunch, peak glucose concentrations were lower with brief periodic exercise than those with postprandial exercise (97 ± 5 and 108 ± 8 mg/dl, P < 0.05, effect size = 0.484). After dinner, peak glucose concentrations did not significantly differ among exercise patterns. Areas under the curve over 24 h and 2 h postprandially did not differ among exercise patterns. These findings suggest that brief periodic exercise may be more effective than preprandial and postprandial exercise at attenuating PPG in young active individuals. NEW & NOTEWORTHY This was the first study to investigate the effect of different exercise timing (brief periodic vs. preprandial vs. postprandial exercise) on postprandial glucose (PPG) attenuation in active healthy men. We demonstrated that brief periodic exercise attenuated peak PPG levels more than preprandial and postprandial exercise, particularly in the morning. Additionally, PPG rebounded soon after discontinuing postprandial exercise. Thus, brief periodic exercise may be better than preprandial and postprandial exercise at attenuating PPG levels. Copyright © 2017 the American Physiological Society.
CFA-aware features for steganalysis of color images
NASA Astrophysics Data System (ADS)
Goljan, Miroslav; Fridrich, Jessica
2015-03-01
Color interpolation is a form of upsampling, which introduces constraints on the relationship between neighboring pixels in a color image. These constraints can be utilized to substantially boost the accuracy of steganography detectors. In this paper, we introduce a rich model formed by 3D co-occurrences of color noise residuals split according to the structure of the Bayer color filter array to further improve detection. Some color interpolation algorithms, AHD and PPG, impose pixel constraints so tight that extremely accurate detection becomes possible with merely eight features eliminating the need for model richification. We carry out experiments on non-adaptive LSB matching and the content-adaptive algorithm WOW on five different color interpolation algorithms. In contrast to grayscale images, in color images that exhibit traces of color interpolation the security of WOW is significantly lower and, depending on the interpolation algorithm, may even be lower than non-adaptive LSB matching.
Yacoub, Tamer
2017-11-01
Worldwide, many people with type 2 diabetes are not at recommended glycemic targets and remain at increased risk of microvascular and macrovascular complications. Reaching recommended glycemic targets requires normalizing both fasting and postprandial glucose (PPG). For some patients, this will require addition of a prandial insulin delivered by injection to control PPG excursions. Evidence from epidemiological studies suggests an association between postprandial hyperglycemia and cardiovascular disease, and thus, expert guidelines recommend that treatment for elevated PPG not be delayed. Indeed, studies have demonstrated that PPG makes the greatest contribution to HbA 1c in patients who are approaching, but have not yet reached HbA 1c <7.0%. Appropriately timed exposure of the liver to insulin is critical in suppressing hepatic glucose output (and therefore PPG levels) after a meal. Rapid-acting insulin analogs, with their faster onset and shorter duration of action, offer advantages over regular human insulin. Unfortunately, even with improved pharmacokinetic/pharmacodynamic characteristics, rapid-acting insulin analogs are still unable to fully reproduce the rapid release of insulin into the portal circulation and suppression of hepatic glucose output that occurs in the individual without diabetes after starting a meal. The next generation of rapid-acting insulin analogs will have an even more favorable pharmacokinetic profile that should allow patients to further improve glycemic control. Continuous subcutaneous insulin infusion (CSII) represents another option for intensifying therapy and improving postprandial control in some patients, and studies have shown that the benefits are sustainable long-term. However, it is currently unclear which patients stand to benefit the most from the extra expense and complexity of a CSII regimen, and further studies are needed.
Boers, Hanny M; MacAulay, Katrina; Murray, Peter; Seijen Ten Hoorn, Jack; Hoogenraad, Anne-Roos; Peters, Harry P F; Vente-Spreeuwenberg, Maria A M; Mela, David J
2017-09-01
Type 2 diabetes (T2DM) is increasing, particularly in South-East Asia. Intake of high-glycaemic foods has been positively associated with T2DM, and feasible routes to reduce the glycaemic response to carbohydrate-rich staple foods are needed. The research question was whether different fibre and legume flour mixes in flatbreads lower postprandial glucose (PPG) responses. Using a balanced incomplete block design, we tested the inclusion of guar gum (GG), konjac mannan (KM) and chickpea flour (CPF) in 10 combinations (2/4/6 g GG; 2/4 g KM; 15 g CPF, and 10 or 15 g CPF plus 2 or 4 g GG) in 100 g total of a control commercial high-fibre flatbread flour mix ("atta") on PPG in 38 normal-weight adults. Self-reported appetite was an additional exploratory outcome. An in vitro digestion assay was adapted for flatbreads and assessed for prediction of in vivo PPG. Flatbreads with 6 g GG, 4 g KM, and 15 g CPF plus 2 or 4 g GG reduced PPG ≥30 % (p < 0.01), while no other combinations differed significantly from the control. A statistical model with four in vitro parameters (rate of digestion, %RDS, AUC, carbohydrate level) was highly predictive of PPG results (adjusted R 2 = 0.89). Test products were similar to the control for appetite-related measures. The results confirm the efficacy of specific additions to flatbread flour mixes for reducing PPG and the value of the in vitro model as a predictive tool with these ingredients and product format. This trial is registered at ClinicalTrials.gov with identifier NCT02671214.
Mayrhofer, Severine; Pöggeler, Stefanie
2005-04-01
The homothallic filamentous ascomycete Sordaria macrospora possesses genes which are thought to encode two pheromone precursors and two seven-transmembrane pheromone receptors. The pheromone precursor genes are termed ppg1 and ppg2. The putative products derived from the gene sequence show structural similarity to the alpha-factor precursors and a-factor precursors of the yeast Saccharomyces cerevisiae. Likewise, sequence similarity has been found between the putative products of the pheromone receptor genes pre2 and pre1 and the S. cerevisiae Ste2p alpha-factor receptor and Ste3p a-factor receptor, respectively. To investigate whether the alpha-factor-like pheromone-receptor pair of S. macrospora is functional, a heterologous yeast assay was used. Our results show that the S. macrospora alpha-factor-like pheromone precursor PPG1 is processed into an active pheromone by yeast MATalpha cells. The S. macrospora PRE2 protein was demonstrated to be a peptide pheromone receptor. In yeast MATa cells lacking the endogenous Ste2p receptor, the S. macrospora PRE2 receptor facilitated all aspects of the pheromone response. Using a synthetic peptide, we can now predict the sequence of one active form of the S. macrospora peptide pheromone. We proved that S. macrospora wild-type strains secrete an active pheromone into the culture medium and that disruption of the ppg1 gene in S. macrospora prevents pheromone production. However, loss of the ppg1 gene does not affect vegetative growth or fertility. Finally, we established the yeast assay as an easy and useful system for analyzing pheromone production in developmental mutants of S. macrospora.
Glass, Leslie L; Calero-Nieto, Fernando J; Jawaid, Wajid; Larraufie, Pierre; Kay, Richard G; Göttgens, Berthold; Reimann, Frank; Gribble, Fiona M
2017-10-01
To identify sub-populations of intestinal preproglucagon-expressing (PPG) cells producing Glucagon-like Peptide-1, and their associated expression profiles of sensory receptors, thereby enabling the discovery of therapeutic strategies that target these cell populations for the treatment of diabetes and obesity. We performed single cell RNA sequencing of PPG-cells purified by flow cytometry from the upper small intestine of 3 GLU-Venus mice. Cells from 2 mice were sequenced at low depth, and from the third mouse at high depth. High quality sequencing data from 234 PPG-cells were used to identify clusters by tSNE analysis. qPCR was performed to compare the longitudinal and crypt/villus locations of cluster-specific genes. Immunofluorescence and mass spectrometry were used to confirm protein expression. PPG-cells formed 3 major clusters: a group with typical characteristics of classical L-cells, including high expression of Gcg and Pyy (comprising 51% of all PPG-cells); a cell type overlapping with Gip-expressing K-cells (14%); and a unique cluster expressing Tph1 and Pzp that was predominantly located in proximal small intestine villi and co-produced 5-HT (35%). Expression of G-protein coupled receptors differed between clusters, suggesting the cell types are differentially regulated and would be differentially targetable. Our findings support the emerging concept that many enteroendocrine cell populations are highly overlapping, with individual cells producing a range of peptides previously assigned to distinct cell types. Different receptor expression profiles across the clusters highlight potential drug targets to increase gut hormone secretion for the treatment of diabetes and obesity. Copyright © 2017 The Authors. Published by Elsevier GmbH.. All rights reserved.
Garlic intake lowers fasting blood glucose: meta-analysis of randomized controlled trials.
Hou, Li-qiong; Liu, Yun-hui; Zhang, Yi-yi
2015-01-01
Garlic is a common spicy flavouring agent also used for certain therapeutic purposes. Garlic's effects on blood glucose have been the subject of many clinical and animal studies, however, studies reporting hypoglycemic effects of garlic in humans are conflicting. A comprehensive literature search was conducted to identify relevant trials of garlic or garlic extracts on markers of glycemic control [fasting blood glucose (FBG), postprandial glucose (PPG), glycosylated haemoglobin (HbA1c)]. A meta-analysis of the effect of garlic intake on human was done to assess garlic's effectiveness in lowering glucose levels. Two reviewers extracted data from each of the identified studies. Seven eligible randomized controlled trials with 513 subjects were identified. Pooled analyses showed that garlic intake results in a statistically significant lowering in FBG [SMD=-1.67; 95% CI (-2.80, -0.55), p=0.004]. Our pooled analyses did not include PPG control and HbA1c outcomes. Because only 1 study included in the meta-analysis reported PPG variables and only 2 studies reported HbA1c variables. In conclusion, the current meta-analysis showed that the administration of garlic resulted in a significant reduction in FBG concentrations. More trials are needed to investigate the effectiveness of garlic on HbA1c and PPG.
Bone microvascular flow differs from skin microvascular flow in response to head-down tilt.
Howden, Michelle; Siamwala, Jamila H; Hargens, Alan R
2017-10-01
Loss of hydrostatic pressures in microgravity may alter skin and bone microvascular flows in the lower extremities and potentially reduce wound healing and bone fracture repair. The purpose of this study was to determine the rate at which skin and bone microvascular flows respond to head-down tilt (HDT). We hypothesized that microvascular flows in tibial bone and overlying skin would increase at different rates during HDT. Tibial bone and skin microvascular flows were measured simultaneously using photoplethysmography (PPG) in a total of 17 subjects during sitting (control posture), supine, 6° HDT, 15° HDT, and 30° HDT postures in random order. With greater angles of HDT, bone microvascular flow increased significantly, but skin microvascular flow did not change. Tibial bone microvascular flow increased from the sitting control posture (0.77 ± 0.41 V) to supine (1.95 ± 1.01 V, P = 0.001) and from supine posture to 15° HDT (3.74 ± 2.43 V, P = 0.004) and 30° HDT (3.91 ± 2.68 V, P = 0.006). Skin microvascular flow increased from sitting (0.703 ± 0.75 V) to supine (2.19 ± 1.72 V, P = 0.02) but did not change from supine posture to HDT ( P = 1.0). We show for the first time that microcirculatory flows in skin and bone of the leg respond to simulated microgravity at different rates. These altered levels of blood perfusion may affect rates of wound and bone fracture healing in spaceflight. NEW & NOTEWORTHY Our data show that bone microvascular flow increases more than cutaneous blood flow with greater degrees of head-down tilt. A higher level of perfusion in bone may give insight into the bone mineral density loss in lower extremities of astronauts and why similar tissue degradation is not observed in the skin of the same areas. Copyright © 2017 the American Physiological Society.
Polyfibroblast: A Self-Healing and Galvanic Protection Additive
2012-11-26
MICROCAPSULES 3 3.3 FILTER, DRY, AND REDISPERSE 3 4. NEXT STEPS 4.1 FIELD TEST PREPARATIONS Polyfibroblast Progress Report -2 - 11/26/12 The Johns...Park Research Center to inspect the microcapsules . Despite the challenges of synthesizing them in larger quantities, the PPG microcapsules looked at...least as good as the equivalent APL microcapsules . PPG is now making the 5 gallons of paint for the January field test. 2 Project Goals and
Zahedi, Edmond; Sohani, Vahid; Ali, M A Mohd; Chellappan, Kalaivani; Beng, Gan Kok
2015-01-01
The feasibility of a novel system to reliably estimate the normalized central blood pressure (CBPN) from the radial photoplethysmogram (PPG) is investigated. Right-wrist radial blood pressure and left-wrist PPG were simultaneously recorded in five different days. An industry-standard applanation tonometer was employed for recording radial blood pressure. The CBP waveform was amplitude-normalized to determine CBPN. A total of fifteen second-order autoregressive models with exogenous input were investigated using system identification techniques. Among these 15 models, the model producing the lowest coefficient of variation (CV) of the fitness during the five days was selected as the reference model. Results show that the proposed model is able to faithfully reproduce CBPN (mean fitness = 85.2% ± 2.5%) from the radial PPG for all 15 segments during the five recording days. The low CV value of 3.35% suggests a stable model valid for different recording days.
Zhao, Li; Guo, Zhihou; Liu, Jiali; Wang, Zi; Wang, Ruichong; Li, Yijing; Wang, Li; Xu, Yigang; Tang, Lijie; Qiao, Xinyuan
2017-07-13
The present study used Lactobacillus casei ATCC 393 as antigen delivery system to express C. perfringens toxoids α-β2-ε-β1 to construct the recombination Lactobacillus casei pPG-2-α-β2-ε-β1/L. casei 393. After being induced by 1% xylose, the specificity and integrity of recombinant strain were determined by Western-blotting. Rabbits as native animal model were immunized orally with pPG-2-α-β2-ε-β1/L. casei 393 and the titers of specific IgG and sIgA were determined by ELISA. The result showed that oral administration with the recombinants could elicit both local mucosal and systemic immune responses. The proliferation of spleen lymphocytes in rabbits immunized with pPG-2-α-β2-ε-β1/L. casei 393 was observed. Levels of IL-4 and IFN-γ produced were significantly higher in lymphocytes isolated from the vaccine group than those from the control groups. Flow cytometry assay showed that both the percentages of CD4+T cells and CD8+T cells from the vaccine group were significantly increased than the control groups. All these results showed that immunizing with recombinants can elicit both humoral immunity and cellular immunity. Besides, in order to determine the effectiveness of oral immunization with pPG-2-α-β2-ε-β1/L. casei 393, rabbits of vaccine group and control groups were challenged with 1×LD 100 unit of culture filtrate of C. perfringens type C and type D toxins respectively. After challenge, 100% of the immunized rabbits survived, while the rabbits of the control group were killed within 48h. Observation on histopathology showed that histopathological changes were obviously found in heart, liver, spleen, lung, kidney, intestine and brain of rabbits from the control groups, while no apparent histopathological change was observed in the vaccine group. All the results show that pPG-2-α-β2-ε-β1/L. casei 393 can eliciteffective immunoprotection against C. perfringens. All of these suggest that the use of pPG-2-α-β2-ε-β1/L. casei 393 can be regarded as candidate for the development of a vaccine against C. perfringens. Copyright © 2017 Elsevier Ltd. All rights reserved.
Warren, Kristen M; Harvey, Joshua R; Chon, Ki H; Mendelson, Yitzhak
2016-03-07
Photoplethysmographic (PPG) waveforms are used to acquire pulse rate (PR) measurements from pulsatile arterial blood volume. PPG waveforms are highly susceptible to motion artifacts (MA), limiting the implementation of PR measurements in mobile physiological monitoring devices. Previous studies have shown that multichannel photoplethysmograms can successfully acquire diverse signal information during simple, repetitive motion, leading to differences in motion tolerance across channels. In this paper, we investigate the performance of a custom-built multichannel forehead-mounted photoplethysmographic sensor under a variety of intense motion artifacts. We introduce an advanced multichannel template-matching algorithm that chooses the channel with the least motion artifact to calculate PR for each time instant. We show that for a wide variety of random motion, channels respond differently to motion artifacts, and the multichannel estimate outperforms single-channel estimates in terms of motion tolerance, signal quality, and PR errors. We have acquired 31 data sets consisting of PPG waveforms corrupted by random motion and show that the accuracy of PR measurements achieved was increased by up to 2.7 bpm when the multichannel-switching algorithm was compared to individual channels. The percentage of PR measurements with error ≤ 5 bpm during motion increased by 18.9% when the multichannel switching algorithm was compared to the mean PR from all channels. Moreover, our algorithm enables automatic selection of the best signal fidelity channel at each time point among the multichannel PPG data.
NASA Astrophysics Data System (ADS)
Hickey, Michelle; Phillips, Justin P.; Kyriacou, Panayiotis
2015-03-01
The aim of the current work is to investigate the possibility of augmenting pulse oximetry algorithms to enable the estimation of venous parameters in peripheral tissues. In order to further understand the contribution of venous blood to the photoplethysmographic (PPG) signal, recordings were made from six healthy volunteer subjects during an exercise in which the right hand was placed in various positions above and below heart level. The left hand was kept at heart level as a control while the right hand was moved. A custom-made two-channel dual wavelength PPG instrumentation system was used to obtain the red and infrared plethysmographic signals from both the right and left index fingers simultaneously using identical sensors. Laser Doppler flowmetry signals were also recorded from an adjacent fingertip on the right hand. Analysis of all acquired PPG signals indicated changes in both ac and dc amplitude of the right hand when the position was changed, while those obtained from the left (control) hand remained relatively constant. Most clearly, in the change from heart level to 50cm below heart level there is a substantial decrease in both dc and ac amplitudes. This decrease in dc amplitude most likely corresponds to increased venous pooling, and hence increased absorption of light. It is speculated that the decrease in ac PPG amplitude is due to reduced arterial emptying during diastole due to increased downstream resistance due to venous pooling.
Enhancing the estimation of blood pressure using pulse arrival time and two confounding factors.
Baek, Hyun Jae; Kim, Ko Keun; Kim, Jung Soo; Lee, Boreom; Park, Kwang Suk
2010-02-01
A new method of blood pressure (BP) estimation using multiple regression with pulse arrival time (PAT) and two confounding factors was evaluated in clinical and unconstrained monitoring situations. For the first analysis with clinical data, electrocardiogram (ECG), photoplethysmogram (PPG) and invasive BP signals were obtained by a conventional patient monitoring device during surgery. In the second analysis, ECG, PPG and non-invasive BP were measured using systems developed to obtain data under conditions in which the subject was not constrained. To enhance the performance of BP estimation methods, heart rate (HR) and arterial stiffness were considered as confounding factors in regression analysis. The PAT and HR were easily extracted from ECG and PPG signals. For arterial stiffness, the duration from the maximum derivative point to the maximum of the dicrotic notch in the PPG signal, a parameter called TDB, was employed. In two experiments that normally cause BP variation, the correlation between measured BP and the estimated BP was investigated. Multiple-regression analysis with the two confounding factors improved correlation coefficients for diastolic blood pressure and systolic blood pressure to acceptable confidence levels, compared to existing methods that consider PAT only. In addition, reproducibility for the proposed method was determined using constructed test sets. Our results demonstrate that non-invasive, non-intrusive BP estimation can be obtained using methods that can be applied in both clinical and daily healthcare situations.
Not Waiting for Godot: The Evolution of Health Promotion at PPG Industries.
Colombi, Alberto M; Pringle, Janice L; Welsh, George T
2008-04-01
PPG Industries is a manufacturer of coatings, chemicals, optical products, specialty materials, glass, and fiberglass. The company's approach to healthcare combines perhaps 2 disparate concepts. The first is that employee health and behavior change relies to a large degree on employee awareness and ownership of their own health and second that "what gets measured gets done." It is widely acknowledged that one of the best tools for employee awareness is the health risk appraisal tool. Additional components of employee awareness include knowing key individual health metrics and effectively engaging with healthcare providers. As a leading global manufacturer, PPG well understands the critical importance of cost accounting and financial metrics to drive business decisions. PPG's perhaps unique approach comes from the strong marriage of individual health/wellness promotion and frequent, timely, and informative financial metrics on health and the cost of care. Combining capacity building through the mobilization of volunteer wellness teams with expert interventions and financial discipline is a feature of the experience here described. This approach has resulted in both management and employee engagement in the issue and has allowed PPG to bend the curve of ever-increasing healthcare costs and achieve cost increases per employee at one half the reported national average for companies of comparable size. Because this journal is dedicated to health and drug benefits, we gathered an appropriately representative team composed of a physician, an epidemiologist who resides in a pharmacy school, and a benefits manager. The team evolved from a common vision to identify ways of improving employee health and well-being. The team presented both as keynote speakers and as contributors to a breakout session at the National Symposium on Work-Life organized in 2007 by the National Institute for Occupational Safety and Health, a federal agency of the Centers for Disease Control and Prevention in the Department of Health and Human Services. This article is an account of why and how such a unique team was formed.
Zhang, Jin-Ping; Wang, Na; Xing, Xiao-Yan; Yang, Zhao-Jun; Wang, Xin; Yang, Wen-Ying
2016-07-01
The aim of the present study was to investigate whether the therapeutic efficacy of acarbose and metformin is correlated with baseline HbA1c levels in Chinese patients with newly diagnosed type 2 diabetes mellitus (T2DM). Data for 711 subjects were retrieved from the MARCH (Metformin and AcaRbose in Chinese as initial Hypoglycemic treatment) trial database and reviewed retrospectively. Patients were grouped according to baseline HbA1c levels (<7%, 7%-8%, and >8%) and the results for these three groups were compared between acarbose and metformin treatments. Acarbose and metformin treatment significantly improved T2DM-associated parameters (weight, fasting plasma glucose [FPG], postprandial glucose [PPG], glucagon-like peptide-1 [GLP-1], HOMA-IR, and total cholesterol) across all HbA1c levels. Acarbose decreased PPG and HOMA-β significantly more than metformin, but only in subjects with lower baseline HbA1c (PPG in the <7% and 7%-8%, HOMA-β in the <7% groups; all P < 0.05). Acarbose decreased triglyceride (TG) levels, and the areas under the curve (AUC) for insulin and glucagon more than metformin at all HbA1c levels (P < 0.05). After 24 weeks treatment, metformin decreased FPG levels significantly more than acarbose for all baseline HbA1c groups (all P < 0.001). With the exception of FPG, PPG, and TG levels, differences between the two treatment groups observed at 24 weeks were not detected at 48 weeks. Acarbose decreased PPG and TG and spared the AUC for insulin more effectively in patients with low-to-moderate baseline HbA1c levels, whereas metformin induced greater reductions in FPG. These results may help guide selection of initial therapy based on baseline HbA1c. © 2015 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.
Not Waiting for Godot: The Evolution of Health Promotion at PPG Industries
Colombi, Alberto M.; Pringle, Janice L.; Welsh, George T.
2008-01-01
PPG Industries is a manufacturer of coatings, chemicals, optical products, specialty materials, glass, and fiberglass. The company's approach to healthcare combines perhaps 2 disparate concepts. The first is that employee health and behavior change relies to a large degree on employee awareness and ownership of their own health and second that “what gets measured gets done.” It is widely acknowledged that one of the best tools for employee awareness is the health risk appraisal tool. Additional components of employee awareness include knowing key individual health metrics and effectively engaging with healthcare providers. As a leading global manufacturer, PPG well understands the critical importance of cost accounting and financial metrics to drive business decisions. PPG's perhaps unique approach comes from the strong marriage of individual health/wellness promotion and frequent, timely, and informative financial metrics on health and the cost of care. Combining capacity building through the mobilization of volunteer wellness teams with expert interventions and financial discipline is a feature of the experience here described. This approach has resulted in both management and employee engagement in the issue and has allowed PPG to bend the curve of ever-increasing healthcare costs and achieve cost increases per employee at one half the reported national average for companies of comparable size. Because this journal is dedicated to health and drug benefits, we gathered an appropriately representative team composed of a physician, an epidemiologist who resides in a pharmacy school, and a benefits manager. The team evolved from a common vision to identify ways of improving employee health and well-being. The team presented both as keynote speakers and as contributors to a breakout session at the National Symposium on Work-Life organized in 2007 by the National Institute for Occupational Safety and Health, a federal agency of the Centers for Disease Control and Prevention in the Department of Health and Human Services. This article is an account of why and how such a unique team was formed. PMID:25126222
Weiss, Katharina; Strohm, Erhard; Kaltenpoth, Martin; Herzner, Gudrun
2015-12-21
Hymenoptera that mass-provision their offspring have evolved elaborate antimicrobial strategies to ward off fungal infestation of the highly nutritive larval food. Females of the Afro-European Philanthus triangulum and the South American Trachypus elongatus (Crabronidae, Philanthinae) embalm their prey, paralyzed bees, with a secretion from a complex postpharyngeal gland (PPG). This coating consists of mainly unsaturated hydrocarbons and reduces water accumulation on the prey's surface, thus rendering it unfavorable for fungal growth. Here we (1) investigated whether a North American Philanthus species also employs prey embalming and (2) assessed the occurrence and morphology of a PPG among females of the subfamily Philanthinae in order to elucidate the evolution of prey embalming as an antimicrobial strategy. We provide clear evidence that females of the North American Philanthus gibbosus possess large PPGs and embalm their prey. The comparative analyses of 26 species from six genera of the Philanthinae, using histological methods and 3D-reconstructions, revealed pronounced differences in gland morphology within the subfamily. A formal statistical analysis based on defined characters of the glands confirmed that while all members of the derived tribe Philanthini have large and complex PPGs, species of the two more basal tribes, Cercerini and Aphilanthopsini, possess simple and comparatively small glands. According to an ancestral state reconstruction, the complex PPG most likely evolved in the last common ancestor of the Philanthini, thus representing an autapomorphy of this tribe. Prey embalming, as described for P. triangulum and T. elongatus, and now also for P. gibbosus, most probably requires a complex PPG. Hence, the morphology and size of the PPG may allow for inferences about the origin and distribution of the prey embalming behavior within the Philanthinae. Based on our results, we suggest that prey embalming has evolved as an antimicrobial strategy in and is restricted to the tribe Philanthini, which seems to face exceptional threats with regard to fungal infestations of their larval provisions.
Li, Y; Xu, D B; Wang, H J
2016-07-20
To analyze the effects of exogenous hydrogen sulfide on the secretion of growth factors basic fibroblast growth factor (bFGF) and transforming growth factor β1 (TGF-β1), as well as inflammatory mediators tumor necrosis factor α (TNF-α) and interleukin 1β (IL-1β) in macrophages of deep partial-thickness burn wound in rats. Seventy-eight SD rats were divided into normal control group (n=6), pure burn group, sodium hydrosulfide group, propargylglycine (PPG) group, and sodium hydrosulfide+ PPG group according to the random number table, with 18 rats in each of the latter four groups. Rats in normal control group did not receive any treatment, while rats in the other four groups were inflicted with 5% total burn surface area deep partial-thickness scald (hereinafter referred to as burn) on the back. Immediately after burn, rats in pure burn group, sodium hydrosulfide group, and group PPG were intraperitoneally injected with saline 2 mL/kg, sodium hydrosulfide 56 μmol/kg, and PPG 45 mg/kg respectively, while those in sodium hydrosulfide+ PPG group were intraperitoneally injected with sodium hydrosulfide 56 μmol/kg and PPG 45 mg/kg, once a day till the day before harvesting specimen. Six rats of normal control group fed for one week, and 6 rats from each of the rest four groups on post injury day (PID) 3, 7, 14 were collected respectively. Normal skin on the back of rats in normal control group and tissue in the base of wound of rats in the other four groups were harvested to isolate macrophages, and then the content of bFGF, TGF-β1, TNF-α, and IL-1β in culture supernatant of macrophages was detected with enzyme-linked immunosorbent assay. Data were processed with one-way analysis of variance, analysis of variance of factorial design, and LSD test. Compared with that of normal control group [(42.6±2.5) and (18±4) pg/mL], the content of bFGF and TGF-β1 in culture supernatant of macrophages of rats in pure burn group was obviously increased at each time point (with P values below 0.01), peaking on PID 14 at (141.6±7.7) and (580±16) pg/mL respectively. Compared with that of pure burn group, the content of bFGF and TGF-β1 in culture supernatant of macrophages of rats in sodium hydrosulfide group was obviously increased at each time point (with P values below 0.01), peaking on PID 14 at (193.7±10.9) and (793±12) pg/mL respectively, while the content of bFGF and TGF-β1 in culture supernatant of macrophages of rats in group PPG was obviously decreased at each time point (with P values below 0.01), reaching the nadir on PID 3 at (62.0±7.1) and (170±10) pg/mL respectively. The content of bFGF and TGF-β1 in culture supernatant of macrophages of rats in sodium hydrosulfide+ PPG group was obviously lower than that of sodium hydrosulfide group but obviously higher than that of group PPG at each time point (with P values below 0.01), peaking on PID 14 at (151.3±9.0) and (579±9) pg/mL respectively. Compared with that of normal control group [(97±6) and (31±6) pg/mL], the content of TNF-α and IL-1β in culture supernatant of macrophages of rats in pure burn group was obviously increased at each time point (with P values below 0.01), peaking on PID 3 at (924±8) and (290±10) pg/mL respectively. Compared with that of pure burn group, the content of TNF-α and IL-1β in culture supernatant of macrophages of rats in sodium hydrosulfide group was obviously decreased at each time point (with P values below 0.01), reaching the nadir on PID 14 at (346±10) and (120±5) pg/mL respectively, while the content of TNF-α and IL-1β in culture supernatant of macrophages of rats in group PPG was obviously increased at each time point (with P values below 0.01), peaking on PID 3 at (1 232±13) and (410±10) pg/mL respectively. The content of TNF-α and IL-1β in culture supernatant of macrophages of rats in sodium hydrosulfide+ PPG group was obviously higher than that of sodium hydrosulfide group but obviously lower than that of group PPG at each time point (with P values below 0.01), reaching the nadir on PID 14 at (488±16) and (144±6) pg/mL respectively. Supplementation of exogenous hydrogen sulfide in small dosage can increase the secretion of growth factors bFGF and TGF-β1 in macrophages of wound in rats with deep partial-thickness burn in the early stage and reduce the release of inflammatory mediators TNF-α and IL-1β in the meantime, thus affecting the healing of wound.
Toe pressure determination by audiophotoplethysmography.
Fronek, A; Blazek, V; Curran, B
1994-08-01
The purpose of this study was to evaluate the performance of audiophotoplethysmography as a modality to measure toe pressure without the requirement of a recorder. A portable photoplethysmograph with an audio output was used to determine toe pressures, and the results were compared with those obtained by a commercial photoplethysmograph with a recorder. Thirty-one measurements in control subjects and 62 measurements in patients with arterial occlusive disease were performed. The average toe pressure recorded with oscillography with standard photoplethysmography was 103.5 mm Hg +/- 14.7 SD and 95.9 mm Hg +/- 13.4 SD with audio-photoplethysmography. In the patient group the pressure recorded with a commercial photoplethysmograph was 65.3 mm Hg +/- 34.9 SD compared with 61.6 mm Hg +/- 34.8 SD obtained with audio-photoplethysmography. The difference in both groups was insignificant, and the correlation between both methods was very good. A portable hand-held photoplethysmograph equipped with an audio output was used to measure toe pressure in control subjects and in patients with arterial occlusive disease. The results have been compared with the oscillometric method by a standard commercial photoplethysmograph connected to a recorder. The correlation was very good in the control and patient groups, and the difference between both methods was below the level of statistical significance. The fact that no recorder is needed may help in introducing toe pressure measurement into everyday office diagnostic practice.
Lee, Jihyoung; Matsumura, Kenta; Yamakoshi, Takehiro; Rolfe, Peter; Tanaka, Naoto; Kim, Kyungho; Yamakoshi, Ken-ichi
2013-03-01
Normalized pulse volume (NPV) derived from the ear has the potential to be a practical index for monitoring daily life stress. However, ear NPV has not yet been validated. Therefore, we compared NPV derived from an index finger using transmission photoplethysmography as a reference, with NPV derived from a middle finger and four sites of the ear using reflection photoplethysmography during baseline and while performing cold and warm water immersion in ten young and six middle-aged subjects. The results showed that logarithmically-transformed NPV (lnNPV) during cold water immersion as compared with baseline values was significantly lower, only at the index finger, the middle finger and the bottom of the ear-canal. Furthermore, lnNPV reactivities (ΔlnNPV; the difference between baseline and test values) from an index finger were significantly related to ΔlnNPV from the middle finger and the bottom of the ear-canal (young: r = 0.90 and 0.62, middle-aged: r = 0.80 and 0.58, respectively). In conclusion, these findings show that reflection and transmission photoplethysmography are comparable methods to derive NPV in accordance with our theoretical prediction. NPV derived from the bottom of the ear-canal is a valid approach, which could be useful for evaluating daily life stress.
Evaluation of Advanced Polymers for Additive Manufacturing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rios, Orlando; Carter, William G.; Kutchko, Cindy
The goal of this Manufacturing Demonstration Facility (MDF) technical collaboration project between Oak Ridge National Laboratory (ORNL) and PPG Industries, Inc. (PPG) was to evaluate the feasibility of using conventional coatings chemistry and technology to build up material layer-by-layer. The PPG-ORNL study successfully demonstrated that polymeric coatings formulations may overcome many limitations of common thermoplastics used in additive manufacturing (AM), allow lightweight nozzle design for material deposition, and increase build rate. The materials effort focused on layer-by-layer deposition of coatings with each layer fusing together. The combination of materials and deposition results in an additively manufactured build that has sufficientmore » mechanical properties to bear the load of additional layers, yet is capable of bonding across the z-layers to improve build direction strength. The formulation properties were tuned to enable a novel, high-throughput deposition method that is highly scalable, compatible with high loading of reinforcing fillers, and inherently low-cost.« less
[Research on the modification of Kevlar fiber by polypropylene glycol and cis-2-butene-1,4-diol].
Zheng, Yu-ying; Wang, Can-yao; Fu, Ming-lian; Cai, Wei-long; Wang, Liang-en
2005-03-01
The mechanism of the modification of Kevlar fiber by polypropylene glycol(PPG) and cis-2-butene-1, 4-diol was studied in the paper, the authors learned the esterification of toluene-2, 4-diisocyanate (TDI) onto Kevlar fiber by infrared spectrum. In the mean time, the infrared spectrograms of the productions which steadily disposed by PPG and butendiol were analysed respectively, the result showed that the intensity of the bands was reinforced at about 1700-1720 cm(-1) after the samples were steadily disposed, that is to say, the group of --NCO has been stabilized into --NHCO group, the effect of steady disposal was obvious; but the disposal effect of butendiol was apparently better than PPG's at the same condition. Finally, the authors compared the influence of different mol rates between TDI and butendiol on the productions. Based onthe consequence, excessive butendiol would prevent the Kevlar fiber from farther reaction, therefore, the mol rate between TDI and butendiol should approach 1:1.
Watanabe, Nobumoto; Sekine, Tomomi; Takagi, Masatoshi; Iwasaki, Jun-ichi; Imamoto, Naoko; Kawasaki, Hisashi; Osada, Hiroyuki
2009-01-23
Polo-like kinase 1 (Plk1) is one of the key regulators of mitotic cell division. In addition to an N-terminal protein kinase catalytic domain, Plk1 possesses a phosphopeptide binding domain named polo box domain (PBD) at its C terminus. PBD is postulated to be essential for Plk1 localization and substrate targeting. Here, we developed a high-throughput screening system to identify inhibitors of PBD-dependent binding and screened a chemical library. We isolated a benzotropolone-containing natural compound derived from nutgalls (purpurogallin (PPG)) that inhibited PBD-dependent binding in vitro and in vivo. PPG not only delayed the onset of mitosis but also prolonged the progression of mitosis in HeLa cells. Although apparently normal bipolar spindles were formed even in the presence of PPG, the perturbation of chromosome alignment at metaphase plates activated the spindle assembly checkpoint pathway. These results demonstrate the predominant role of PBD-dependent binding on smooth chromosome congression at metaphase.
NASA Astrophysics Data System (ADS)
Choi, Hwa-Jeong; Song, Young-Min; Chung, Ildoo; Ryu, Kwang-Sun; Jo, Nam-Ju
2009-02-01
Conducting polymers (CPs), such as polypyrrole, polythiophene, and polyaniline, are unique in that they have switchable properties due to their two or more mechanically stable oxidation states. Thus, their films or coatings can be easily switched by the application of a small voltage and current to change their volume during electrochemical redox processes. In particular, polypyrrole (PPy) has been studied most extensively because of its high electrical conductivity and good environmental stability under ambient conditions. In this work, we have studied a new CP actuator, fully polymeric, assembled with two PPy film electrodes and a solid polymer electrolyte (SPE), polyurethane/Mg(ClO4)2. Polyurethanes (PUs) were synthesized from 4,4'-diphenylmethane diisocyanate (MDI), 1,4-butanediol (1,4-BD) and three types of polyol: poly(ethylene glycol) (PEG), poly(propylene glycol) (PPG), and PPG-block-PEG-block-PPG (PPG-co-PEG). The chemical polymerization of PPy by immersion in Py monomer aqueous solution and oxidant aqueous solution is an adequate method to prepare PU/PPy composite film as an actuator. To find the proper thickness of the PPy coating layer for actuation, we measured the displacements of the actuators according to the thickness of the PPy coating layer. The displacement of all actuators is discussed in connection with the properties of the SPE and PPy. All the results obtained in this work show the feasibility of electrochemomechanical devices based on PPy and SPE film being able to work in air.
Li, Kejia; Warren, Steve; Natarajan, Balasubramaniam
2012-02-01
Onboard assessment of photoplethysmogram (PPG) quality could reduce unnecessary data transmission on battery-powered wireless pulse oximeters and improve the viability of the electronic patient records to which these data are stored. These algorithms show promise to increase the intelligence level of former "dumb" medical devices: devices that acquire and forward data but leave data interpretation to the clinician or host system. To this end, the authors have developed a unique onboard feature detection algorithm to assess the quality of PPGs acquired with a custom reflectance mode, wireless pulse oximeter. The algorithm uses a Bayesian hypothesis testing method to analyze four features extracted from raw and decimated PPG data in order to determine whether the original data comprise valid PPG waveforms or whether they are corrupted by motion or other environmental influences. Based on these results, the algorithm further calculates heart rate and blood oxygen saturation from a "compact representation" structure. PPG data were collected from 47 subjects to train the feature detection algorithm and to gauge their performance. A MATLAB interface was also developed to visualize the features extracted, the algorithm flow, and the decision results, where all algorithm-related parameters and decisions were ascertained on the wireless unit prior to transmission. For the data sets acquired here, the algorithm was 99% effective in identifying clean, usable PPGs versus nonsaturated data that did not demonstrate meaningful pulsatile waveshapes, PPGs corrupted by motion artifact, and data affected by signal saturation.
Shin, Il-Hyung; Cha, Jaepyeong; Cheon, Gyeong Woo; Lee, Choonghee; Lee, Seung Yup; Yoon, Hyung-Jin; Kim, Hee Chan
2014-01-01
This paper presents an automatic stress-relieving music recommendation system (ASMRS) for individual music listeners. The ASMRS uses a portable, wireless photoplethysmography module with a finger-type sensor, and a program that translates heartbeat signals from the sensor to the stress index. The sympathovagal balance index (SVI) was calculated from heart rate variability to assess the user's stress levels while listening to music. Twenty-two healthy volunteers participated in the experiment. The results have shown that the participants' SVI values are highly correlated with their prespecified music preferences. The sensitivity and specificity of the favorable music classification also improved as the number of music repetitions increased to 20 times. Based on the SVI values, the system automatically recommends favorable music lists to relieve stress for individuals.
Recovery Act: Low Cost Integrated Substrate for OLED Lighting Development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Benton, Scott; Bhandari, Abhinav
2012-12-26
PPG pursued the development of an integrated substrate, including the anode, external, and internal extraction layers. The objective of PPG's program was to achieve cost reductions by displacing the existing expensive borosilicate or double-side polished float glass substrates and developing alternative electrodes and scalable light extraction layer technologies through focused and short-term applied research. One of the key highlights of the project was proving the feasibility of using PPG's high transmission Solarphire® float glass as a substrate to consistently achieve organic lightemitting diode (OLED) devices with good performance and high yields. Under this program, four low-cost alternatives to the Indiummore » Tin Oxide (ITO) anode were investigated using pilot-scale magnetron sputtered vacuum deposition (MSVD) and chemical vapor deposition (CVD) technologies. The anodes were evaluated by fabricating small and large phosphorescent organic lightemitting diode (PHOLED) devices at Universal Display Corporation (UDC). The device performance and life-times comparable to commercially available ITO anodes were demonstrated. A cost-benefit analysis was performed to down-select two anodes for further low-cost process development. Additionally, PPG developed and evaluated a number of scalable and compatible internal and external extraction layer concepts such as scattering layers on the outside of the glass substrate or between the transparent anode and the glass interface. In one external extraction layer (EEL) approach, sol-gel sprayed pyrolytic coatings were deposited using lab scale equipment by hand or automated spraying of sol-gel solutions on hot glass, followed by optimizing of scattering with minimal absorption. In another EEL approach, PPG tested large-area glass texturing by scratching a glass surface with an abrasive roller and acid etching. Efficacy enhancements of 1.27x were demonstrated using white PHOLED devices for 2.0mm substrates which are at par with the standard diffuser sheets used by OLED manufacturers. For an internal extraction layer (IEL), PPG tested two concepts combining nanoparticles either in a solgel coating inserted between the anode and OLED or anode and glass interface, or incorporated into the internal surface of the glass. Efficacy enhancements of 1.31x were demonstrated using white PHOLED devices for the IEL by itself and factors of 1.73x were attained for an IEL in combination of thick acrylic block as an EEL. Recent offline measurements indicate that, with further optimization, factors over 2.0x could be achieved through an IEL alone.« less
Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion
NASA Astrophysics Data System (ADS)
Kyriacou, P. A.; Shafqat, K.; Pal, S. K.
2007-10-01
Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO2) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO2) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO2 sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures. Both pulse oximeters showed gradual decrease of saturations during induced hypoperfusion which demonstrate the direct relation between blood volumes (PPG amplitudes), arterial vessel stenosis and blood oxygen saturation. The custom made pulse oximeter was found to be more sensitive to SpO2 changes than the commercial pulse oximeter especially at high occluding pressures.
Weiss, Katharina; Herzner, Gudrun; Strohm, Erhard
2017-06-06
Sexual selection is thought to promote evolutionary changes and diversification. However, the impact of sexual selection in relation to other selective forces is difficult to evaluate. Male digger wasps of the tribe Philanthini (Hymenoptera, Philanthinae) scent mark territories to attract receptive females. Consequently, the organs for production and storage of the marking secretion, the mandibular gland (MG) and the postpharyngeal gland (PPG), are subject to sexual selection. In female Philanthini, these glands are most likely solely subject to natural selection and show very little morphological diversity. According to the hypothesis that sexual selection drives interspecific diversity, we predicted that the MG and PPG show higher interspecific variation in males than in females. Using histological methods, 3D-reconstructions, and multivariate statistical analysis of morphological characters, we conducted a comparative analysis of the MG and the PPG in males of 30 species of Philanthini and three species of the Cercerini and Aphilanthopsini, two related tribes within the Philanthinae. We found substantial interspecific diversity in gland morphology with regard to gland incidence, size, shape and the type of associated secretory cells. Overall there was a phylogenetic trend: Ensuing from the large MGs and small PPGs of male Cercerini and Aphilanthopsini, the size and complexity of the MG was reduced in male Philanthini, while their PPG became considerably enlarged, substantially more complex, and associated with an apparently novel type of secretory cells. In some clades of the Philanthini the MG was even lost and entirely replaced by the PPG. However, several species showed reversals of and exceptions from this trend. Head gland morphology was significantly more diverse among male than among female Philanthinae. Our results show considerable variation in male head glands including the loss of an entire gland system and the evolution of a novel kind of secretory cells, confirming the prediction that interspecific diversity in head gland morphology is higher in male than in female Philanthini. We discuss possible causes for the remarkable evolutionary changes in males and we conclude that this high diversity has been caused by sexual selection.
Sex differences in patterns of genital sexual arousal: measurement artifacts or true phenomena?
Suschinsky, Kelly D; Lalumière, Martin L; Chivers, Meredith L
2009-08-01
Sex differences in patterns of sexual arousal have been reported recently. Men's genital arousal is typically more category-specific than women's, such that men experience their greatest genital arousal to stimuli depicting their preferred sex partners whereas women experience significant genital arousal to stimuli depicting both their preferred and non-preferred sex partners. In addition, men's genital and subjective sexual arousal patterns are more concordant than women's: The correlation between genital and subjective sexual arousal is much larger in men than in women. These sex differences could be due to low response-specificity in the measurement of genital arousal in women. The most commonly used measure of female sexual arousal, vaginal photoplethysmography, has not been fully validated and may not measure sexual arousal specifically. A total of 20 men and 20 women were presented with various sexual and non-sexual emotionally laden short film clips while their genital and subjective sexual arousal were measured. Results suggest that vaginal photoplethysmography is a measure of sexual arousal exclusively. Women's genital responses were highest during sexual stimuli and absent during all non-sexual stimuli. Sex differences in degree of category-specificity and concordance were replicated: Men's genital responses were more category-specific than women's and men's genital and subjective sexual arousal were more strongly correlated than women's. The results from the current study support the continued use of vaginal photoplethysmography in investigating sex differences in patterns of sexual arousal.
Aydogan, Tuğba; Akçay, BetÜl İlkay Sezgin; Kardeş, Esra; Ergin, Ahmet
2017-11-01
The objective of this study is to evaluate the diagnostic ability of retinal nerve fiber layer (RNFL), macular, optic nerve head (ONH) parameters in healthy subjects, ocular hypertension (OHT), preperimetric glaucoma (PPG), and early glaucoma (EG) patients, to reveal factors affecting the diagnostic ability of spectral domain-optical coherence tomography (SD-OCT) parameters and risk factors for glaucoma. Three hundred and twenty-six eyes (89 healthy, 77 OHT, 94 PPG, and 66 EG eyes) were analyzed. RNFL, macular, and ONH parameters were measured with SD-OCT. The area under the receiver operating characteristic curve (AUC) and sensitivity at 95% specificity was calculated. Logistic regression analysis was used to determine the glaucoma risk factors. Receiver operating characteristic regression analysis was used to evaluate the influence of covariates on the diagnostic ability of parameters. In PPG patients, parameters that had the largest AUC value were average RNFL thickness (0.83) and rim volume (0.83). In EG patients, parameter that had the largest AUC value was average RNFL thickness (0.98). The logistic regression analysis showed average RNFL thickness was a risk factor for both PPG and EG. Diagnostic ability of average RNFL and average ganglion cell complex thickness increased as disease severity increased. Signal strength index did not affect diagnostic abilities. Diagnostic ability of average RNFL and rim area increased as disc area increased. When evaluating patients with glaucoma, patients at risk for glaucoma, and healthy controls RNFL parameters deserve more attention in clinical practice. Further studies are needed to fully understand the influence of covariates on the diagnostic ability of OCT parameters.
Yang, Bufan; Posada-Quintero, Hugo F.; Siu, Kin L.; Rolle, Marsha; Brink, Peter; Birzgalis, Aija; Moore, Leon C.
2014-01-01
In this work, we used a sensitive and noninvasive computational method to assess diabetic cardiovascular autonomic neuropathy (DCAN) from pulse oximeter (photoplethysmographic; PPG) recordings from mice. The method, which could be easily applied to humans, is based on principal dynamic mode (PDM) analysis of heart rate variability (HRV). Unlike the power spectral density, PDM has been shown to be able to separately identify the activities of the parasympathetic and sympathetic nervous systems without pharmacological intervention. HRV parameters were measured by processing PPG signals from conscious 1.5- to 5-month-old C57/BL6 control mice and in Akita mice, a model of insulin-dependent type 1 diabetes, and compared with the gold-standard Western blot and immunohistochemical analyses. The PDM results indicate significant cardiac autonomic impairment in the diabetic mice in comparison to the controls. When tail-cuff PPG recordings were collected and analyzed starting from 1.5 months of age in both C57/Bl6 controls and Akita mice, onset of DCAN was seen at 3 months in the Akita mice, which persisted up to the termination of the recording at 5 months. Western blot and immunohistochemical analyses also showed a reduction in nerve density in Akita mice at 3 and 4 months as compared to the control mice, thus, corroborating our PDM data analysis of HRV records. Western blot analysis of autonomic nerve proteins corroborated the PPG-based HRV analysis via the PDM approach. In contrast, traditional HRV analysis (based on either the power spectral density or time-domain measures) failed to detect the nerve rarefaction. PMID:25097056
Single source photoplethysmograph transducer for local pulse wave velocity measurement.
Nabeel, P M; Joseph, Jayaraj; Awasthi, Vartika; Sivaprakasam, Mohanasankar
2016-08-01
Cuffless evaluation of arterial blood pressure (BP) using pulse wave velocity (PWV) has received attraction over the years. Local PWV based techniques for cuffless BP measurement has more potential in accurate estimation of BP parameters. In this work, we present the design and experimental validation of a novel single-source Photoplethysmograph (PPG) transducer for arterial blood pulse detection and cycle-to-cycle local PWV measurement. The ability of the transducer to continuously measure local PWV was verified using arterial flow phantom as well as by conducting an in-vivo study on 17 volunteers. The single-source PPG transducer could reliably acquire dual blood pulse waveforms, along small artery sections of length less than 28 mm. The transducer was able to perform repeatable measurements of carotid local PWV on multiple subjects with maximum beat-to-beat variation less than 12%. The correlation between measured carotid local PWV and brachial BP parameters were also investigated during the in-vivo study. Study results prove the potential use of newly proposed single-source PPG transducers in continuous cuffless BP measurement systems.
Chen, Zhihao; Yang, Xiufeng; Teo, Ju Teng; Ng, Soon Huat
2013-01-01
A new all optical method for long term and continuous blood pressure measurement and monitoring without using cuffs is proposed by using Ballistocardiography (BCG) and Photoplethysmograph (PPG). Based on BCG signal and PPG signal, a time delay between these two signals is obtained to calculate both systolic blood pressure and diastolic blood pressure via linear regression analysis. The fabricated noninvasive blood pressure monitoring device consists of a fiber sensor mat to measure BCG signal and a SpO2 sensor to measure PPG signal. A commercial digital oscillometric blood pressure meter is used to obtain reference values and for calibration. It has been found that by comparing with the reference device, our prototype has typical means and standard deviations of 9+/-5.6 mmHg for systolic blood pressure, 1.8+/-1.3 mmHg for diastolic blood pressure and 0.6+/-0.9 bpm for pulse rate, respectively. If the fiber optic SpO2 probe is used, this new all fiber cuffless noninvasive blood pressure monitoring device will truly be a MRI safe blood pressure measurement and monitoring device.
SCIENTIFIC LEADERS FOR THE FUTURE: PRIMARY AND SECONDARY EDUCATION.
Nascimento, Fernanda Amorim de Morais; Gregório, Bianca Martins; Souza, Diogo Benchimol de; Sampaio, Francisco José Barcellos; Ferreira, Lydia Masako
2015-01-01
To present a high school insertion pilot project in post graduate programs (PPG) and discuss the mechanisms for the formation of leaders in science. This study presents a review and pilot project. Bibliographic search occurred in sites of CAPES, MEC, SciELO and library of virtual books from January/ 2014 to February/2015. The pilot is in PPG-Medicine III Translational Surgery/UNIFESP and Pathophysiology and Surgical Sciences / UERJ. The junior undergraduate students (ICj) came from public school and develop scientific activities: scientific meetings, graduation and inclusion in research projects. The evaluation will occur at the end of one year, with the results essays, reports and participation in scientific events. In Brazil, one of the main challenges of education is the high average years of study. The PNPG (2011-2020) shows the insertion of basic education in all PPG. In the Pathophysiology and Surgical Sciences/UERJ there are currently 11 high school students who have followed the scientific meetings and are being prepared for the inclusion in research projects. There was 30% of absence, owing to the high school hours. This result and the experience allow creating future alternatives to enhance the integration project. The leadership in science is formed from a complex relationship between basic education and investment in research. PPG-Medicine III courses follow the vanguard with initiatives focused on scientific and technological development. Thus, projects involving basic education students represent promoter model and environment leaders. Apresentar um projeto piloto de inserção do ensino médio em programas de pós-graduação (PPG) e discutir os mecanismos para a formação de líderes em ciência. Realizou-se um estudo de revisão e apresentação de piloto. A busca bibliográfica ocorreu nos sites da CAPES, MEC, Scielo e biblioteca de livros virtuais, de janeiro/2014 a fevereiro/2015. O piloto ocorre nos PPG-Medicina III em Cirurgia Translacional/UNIFESP e Fisiopatologia e Ciências Cirúrgicas/UERJ. Os alunos de iniciação científica júnior (ICj) são oriundos de escola pública e desenvolvem atividades científicas: participação em reuniões científicas, graduação e inserção nos projetos de pesquisa. A avaliação ocorrerá ao final de um ano, com redações dos resultados, relatórios e participações em eventos científicos. No Brasil, um dos principais desafios da educação é a alta média de anos de estudo. O PNPG (2011-2020) apresenta a inserção da educação básica em todos os PPG. Na Fisiopatologia e Ciências Cirúrgicas/UERJ há atualmente 11 alunos do ensino médio, que já acompanharam as reuniões científicas e preparam-se para a inserção em projetos de pesquisa. Houve 30% de desistência, devido à alta carga horária escolar. Esse resultado e a experiência vivenciada permite criar alternativas futuras para aprimorar o projeto de inserção. A liderança em ciências é formada a partir de uma complexa relação entre educação básica e investimentos na pesquisa. Cursos de PPG-Medicina III seguem na vanguarda com iniciativas focadas no desenvolvimento científico e tecnológico. Assim, projetos envolvendo alunos da educação básica representam modelo e ambiente promotor de líderes.
Postoperative pyoderma gangrenosum: A rare complication after appendectomy
Faghihi, G; Abtahi-Naeini, B; Nikyar, Z; Jamshidi, K; Bahrami, A
2015-01-01
Pyoderma gangrenosum (PG) is an uncommon inflammatory ulcerative skin disease. It is characterized by painful progressive necrosis of the wound margins. Rarely, postoperative pyoderma gangrenosum (PPG) manifests as a severe disturbance of wound healing following surgical interventions. Only rare cases of this complication have been reported after appendectomy. We report a case of PPG in a 29-year-old female after appendectomy. She was successfully treated with oral prednisolone. Postoperative pyoderma gangrenosum should be kept in mind in the differential diagnosis of any postoperative delayed wound healing, because this disease is simply distinguished from a postoperative wound. PMID:25511218
Non-invasive multiwavelength photoplethysmography under low partial pressure of oxygen.
Fang, Yung Chieh; Tai, Cheng-Chi
2016-08-01
A reduction in partial pressure of oxygen in the environment may be caused by a gain in altitude, which reduces the atmospheric pressure; it may also be caused by the carbon dioxide generated from breathing in an enclosed space. Does inhaling oxygen of lower partial pressure affect the oxygen-carrying function of haemoglobin in vivo? This study uses non-invasive multiwavelength photoplethysmography to measure the effects that inhaling this type of oxygen can have on the plethysmography of the appendages of the body (fingertips). The results indicate that under low partial pressure of oxygen, be it the result of a gain in carbon dioxide concentration or altitude, the change in visible light absorption is the biggest for short wavelengths (approximately 620 or 640 nm) near deoxyhaemoglobin, which has higher absorption coefficient. Moreover, increasing carbon dioxide concentration from 5000 to 10,000 ppm doubly reduces the absorption rate of these short wavelengths.
Knights, Marlon; Ramgattie, Reeza; Siew, Narendra; Singh-Knights, Doolarie; Bourne, Gregory
2011-06-01
The efficacy of using a low cost system for delivering progesterone as part of an estrous synchronization protocol in sheep was evaluated. In experiment 1, Barbados Black Belly ewes (n=34) and ewe lambs (n=35; 37.5±0.9 kg) were assigned to be untreated, control animals (C), or to receive PGF(2α) on d0 (PG), or receive two injections of progesterone (200mg, i.m. each) on D -5 and on D -2.5, prior to PGF(2α), on D 0 (2PPG). Treatment with 2PPG increased the proportion of animals lambing to the first service (P<0.05), an effect that was greater in ewe lambs than ewes (treatment × parity; P<0.05). The interval from ram introduction to lambing and the mean lambing day was less (P=0.04) in the 2PPG-treated animals compared to control animals. In Experiment 2, lactating ewes from experiment 1 (n=61) 60-85 days postpartum were assigned within parity and number of lambs reared to remain nursing (S; n=29) or weaned (W; n=32) 3 weeks prior to treatment with the 2PPG protocol. There was no effect of treatment on the proportion of animals lambing to the first service or overall, interval from ram introduction to lambing and lambing interval. An 8-month lambing interval was observed in ewes in which estrus was synchronized regardless of physiological state. In conclusion, the two-progesterone injection synchronization protocol may be used as a practical low cost and efficient method of synchronizing estrus to reduce the lambing interval and maximize productivity in tropical breeds of sheep. Copyright © 2011 Elsevier B.V. All rights reserved.
Aydoğan, Tuğba; Akçay, Betül İlkay Sezgin; Kardeş, Esra; Ergin, Ahmet
2017-01-01
Purpose: The objective of this study is to evaluate the diagnostic ability of retinal nerve fiber layer (RNFL), macular, optic nerve head (ONH) parameters in healthy subjects, ocular hypertension (OHT), preperimetric glaucoma (PPG), and early glaucoma (EG) patients, to reveal factors affecting the diagnostic ability of spectral domain-optical coherence tomography (SD-OCT) parameters and risk factors for glaucoma. Methods: Three hundred and twenty-six eyes (89 healthy, 77 OHT, 94 PPG, and 66 EG eyes) were analyzed. RNFL, macular, and ONH parameters were measured with SD-OCT. The area under the receiver operating characteristic curve (AUC) and sensitivity at 95% specificity was calculated. Logistic regression analysis was used to determine the glaucoma risk factors. Receiver operating characteristic regression analysis was used to evaluate the influence of covariates on the diagnostic ability of parameters. Results: In PPG patients, parameters that had the largest AUC value were average RNFL thickness (0.83) and rim volume (0.83). In EG patients, parameter that had the largest AUC value was average RNFL thickness (0.98). The logistic regression analysis showed average RNFL thickness was a risk factor for both PPG and EG. Diagnostic ability of average RNFL and average ganglion cell complex thickness increased as disease severity increased. Signal strength index did not affect diagnostic abilities. Diagnostic ability of average RNFL and rim area increased as disc area increased. Conclusion: When evaluating patients with glaucoma, patients at risk for glaucoma, and healthy controls RNFL parameters deserve more attention in clinical practice. Further studies are needed to fully understand the influence of covariates on the diagnostic ability of OCT parameters. PMID:29133640
Cuff-less PPG based continuous blood pressure monitoring: a smartphone based approach.
Gaurav, Aman; Maheedhar, Maram; Tiwari, Vijay N; Narayanan, Rangavittal
2016-08-01
Cuff-less estimation of systolic (SBP) and diastolic (DBP) blood pressure is an efficient approach for non-invasive and continuous monitoring of an individual's vitals. Although pulse transit time (PTT) based approaches have been successful in estimating the systolic and diastolic blood pressures to a reasonable degree of accuracy, there is still scope for improvement in terms of accuracies. Moreover, PTT approach requires data from sensors placed at two different locations along with individual calibration of physiological parameters for deriving correct estimation of systolic and diastolic blood pressure (BP) and hence is not suitable for smartphone deployment. Heart Rate Variability is one of the extensively used non-invasive parameters to assess cardiovascular autonomic nervous system and is known to be associated with SBP and DBP indirectly. In this work, we propose a novel method to extract a comprehensive set of features by combining PPG signal based and Heart Rate Variability (HRV) related features using a single PPG sensor. Further, these features are fed into a DBP feedback based combinatorial neural network model to arrive at a common weighted average output of DBP and subsequently SBP. Our results show that using this current approach, an accuracy of ±6.8 mmHg for SBP and ±4.7 mmHg for DBP is achievable on 1,750,000 pulses extracted from a public database (comprising 3000 people). Since most of the smartphones are now equipped with PPG sensor, a mobile based cuff-less BP estimation will enable the user to monitor their BP as a vital parameter on demand. This will open new avenues towards development of pervasive and continuous BP monitoring systems leading to an early detection and prevention of cardiovascular diseases.
Andersen, Grit; Meiffren, Grégory; Lamers, Daniela; DeVries, J Hans; Ranson, Aymeric; Seroussi, Cyril; Alluis, Bertrand; Gaudier, Martin; Soula, Olivier; Heise, Tim
2018-06-19
To investigate safety and efficacy of BioChaperone insulin lispro (BCLIS), an ultra-rapid formulation of insulin lispro (LIS) in patients with type 1 diabetes. In this randomized, double-blind study, patients self-administered individualized bolus doses of BCLIS or LIS during two 14-day periods in a crossover fashion. Postprandial blood glucose (PPG) was assessed following individualized solid mixed meal tests (MMT) (50% carbs, 29% fat, 21% proteins) with additional randomization for the sequence of timing of insulin administration, immediately (t0), 15 minutes before (t-15) and 15 minutes after (t+15) meal start on days 1, 2 and 3 and with t0 administration on day 14. Pharmacokinetics (PK) were assessed for t0 MMTs. Patients also used individualized BCLIS or LIS doses immediately before meals during two 10-day outpatient periods with unchanged basal insulin regimen. Overall, 35 patients completed both treatment periods. In MMTs with t0 administration, the higher early postprandial PK exposure of BCLIS led to significant reductions in 1-2 hr PPG excursions by 30-40% vs LIS and the accelerated absorption and action of BCLIS persisted over 14 days. There was no difference in glucose excursion over the full 360 min postprandial period. PPG control was similar between BCLIS injected at t+15 and LIS at t0. BCLIS demonstrated safety and tolerability comparable to LIS. No injection site reactions occurred with BCLIS. BCLIS was well-tolerated and safe over 14 days of treatment and significantly improved PPG versus LIS when administered at mealtime. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Topical tacrolimus for parastomal pyoderma gangrenosum: a report of two cases.
Altieri, Maria; Vaziri, Khashayar; Orkin, Bruce A
2010-09-01
Pyoderma gangrenosum (PG) is an idiopathic, ulcerative, inflammatory dermatologic condition that occurs in patients with systemic diseases such as inflammatory bowel disease (IBD). This inflammatory skin disorder is presumably caused by an autoimmune mechanism and the diagnosis is one of exclusion. PG is not a common condition but it is thought to account for approximately 50% of chronic parastomal ulcers. Refractory parastomal PG (PPG) occurs in patients with inactive disease or after bowel resection. Multiple medical treatments, ranging from topical agents for mild disease to systemic immunosuppressive therapy for severe disease, have been used with varying rates of success. Using topical tacrolimus, an immunosuppressant that inhibits T-lymphocyte proliferation, and meticulous stoma care can result in successful treatment. Two women (ages 59 and 62 years) with a history of ulcerative colitis and colon resection presented with parastomal ulcers consistent with PPG. The 59-year patient presented with a painful 2 cm x 2 cm parastomal ulcer that improved following daily application of topical tacrolimus 0.1%. The 62-year old woman first was prescribed daily appliance changes and application of topical triamcinolone 0.5% to her 3-cm ulcer. The ulcer increased in size and treatment was changed to daily application of tacrolimus 0.1%. After 2 months and a reduction in ulcer size and severity, the dosage was changed to daily application of tacrolimus 0.03%. Both patients reported resolution of pain and itching, the most common symptoms of PPG, and no adverse effects were observed. The encouraging results observed in these two cases confirm that tacrolimus helps resolve PPG lesions even at concentrations previously thought to be ineffective. Additional studies to help clinicians optimize care of these painful lesions are needed.
Quantifying Dynamic Changes in Plantar Pressure Gradient in Diabetics with Peripheral Neuropathy.
Lung, Chi-Wen; Hsiao-Wecksler, Elizabeth T; Burns, Stephanie; Lin, Fang; Jan, Yih-Kuen
2016-01-01
Diabetic foot ulcers remain one of the most serious complications of diabetes. Peak plantar pressure (PPP) and peak pressure gradient (PPG) during walking have been shown to be associated with the development of diabetic foot ulcers. To gain further insight into the mechanical etiology of diabetic foot ulcers, examination of the pressure gradient angle (PGA) has been recently proposed. The PGA quantifies directional variation or orientation of the pressure gradient during walking and provides a measure of whether pressure gradient patterns are concentrated or dispersed along the plantar surface. We hypothesized that diabetics at risk of foot ulceration would have smaller PGA in key plantar regions, suggesting less movement of the pressure gradient over time. A total of 27 participants were studied, including 19 diabetics with peripheral neuropathy and 8 non-diabetic control subjects. A foot pressure measurement system was used to measure plantar pressures during walking. PPP, PPG, and PGA were calculated for four foot regions - first toe (T1), first metatarsal head (M1), second metatarsal head (M2), and heel (HL). Consistent with prior studies, PPP and PPG were significantly larger in the diabetic group compared with non-diabetic controls in the T1 and M1 regions, but not M2 or HL. For example, PPP was 165% (P = 0.02) and PPG was 214% (P < 0.001) larger in T1. PGA was found to be significantly smaller in the diabetic group in T1 (46%, P = 0.04), suggesting a more concentrated pressure gradient pattern under the toe. The proposed PGA may improve our understanding of the role of pressure gradient on the risk of diabetic foot ulcers.
Chan, Pak-Hei; Wong, Chun-Ka; Poh, Yukkee C; Pun, Louise; Leung, Wangie Wan-Chiu; Wong, Yu-Fai; Wong, Michelle Man-Ying; Poh, Ming-Zher; Chu, Daniel Wai-Sing; Siu, Chung-Wah
2016-07-21
Diagnosing atrial fibrillation (AF) before ischemic stroke occurs is a priority for stroke prevention in AF. Smartphone camera-based photoplethysmographic (PPG) pulse waveform measurement discriminates between different heart rhythms, but its ability to diagnose AF in real-world situations has not been adequately investigated. We sought to assess the diagnostic performance of a standalone smartphone PPG application, Cardiio Rhythm, for AF screening in primary care setting. Patients with hypertension, with diabetes mellitus, and/or aged ≥65 years were recruited. A single-lead ECG was recorded by using the AliveCor heart monitor with tracings reviewed subsequently by 2 cardiologists to provide the reference standard. PPG measurements were performed by using the Cardiio Rhythm smartphone application. AF was diagnosed in 28 (2.76%) of 1013 participants. The diagnostic sensitivity of the Cardiio Rhythm for AF detection was 92.9% (95% CI] 77-99%) and was higher than that of the AliveCor automated algorithm (71.4% [95% CI 51-87%]). The specificities of Cardiio Rhythm and the AliveCor automated algorithm were comparable (97.7% [95% CI: 97-99%] versus 99.4% [95% CI 99-100%]). The positive predictive value of the Cardiio Rhythm was lower than that of the AliveCor automated algorithm (53.1% [95% CI 38-67%] versus 76.9% [95% CI 56-91%]); both had a very high negative predictive value (99.8% [95% CI 99-100%] versus 99.2% [95% CI 98-100%]). The Cardiio Rhythm smartphone PPG application provides an accurate and reliable means to detect AF in patients at risk of developing AF and has the potential to enable population-based screening for AF. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Law, Marron; Huot, Pedro S P; Lee, Ying Ti; Vien, Shirley; Luhovyy, Bohdan L; Anderson, G Harvey
2017-11-01
The objective was to compare the effect of dairy and nondairy beverages when consumed with carbohydrate at breakfast on subjective appetite, food intake (FI), and postprandial glycemia (PPG) in healthy young adults. Twenty-six healthy males and females (13 males and 13 females; 23.0 ± 2.6 years; BMI: 22.3 ± 1.5 kg/m 2 ) participated in a randomized crossover study. They consumed nonisocaloric amounts (250 mL) of almond beverage, soy beverage, 1% fat milk, yogurt beverage, and water (control) with cereal and 120 min later, an ad libitum meal. Subjective appetite, PPG, and insulin were measured at baseline and at intervals before and after the meal at which FI was measured. Post-treatment blood glucose was lowest following soy beverage compared with all treatments but was not different from milk (p = 0.0002). There were no differences between any other treatments. However, over the first hour, PPG for all treatments was 27% lower compared with water (p < 0.0001). Milk and yogurt beverage led to the highest insulin concentrations post-treatment (p < 0.0001) but there were no differences between treatments postmeal. All treatments reduced appetite and led to lower FI at the meal compared with water, but FI was lower after milk compared with all treatments except yogurt beverage (p < 0.0001). Both dairy and nondairy beverages consumed with a high glycemic cereal at breakfast increased satiety and decreased FI compared with water with cereal. Despite higher carbohydrate content, all beverages led to similar or lower PPG than the water breakfast, but dairy beverages increased insulin more than nondairy beverages.
Boers, Hanny M; van Dijk, Theo H; Hiemstra, Harry; Hoogenraad, Anne-Roos; Mela, David J; Peters, Harry P F; Vonk, Roel J; Priebe, Marion G
2017-11-01
We previously found that guar gum (GG) and chickpea flour (CPF) added to flatbread wheat flour lowered postprandial blood glucose (PPG) and insulin responses dose dependently. However, rates of glucose influx cannot be determined from PPG, which integrates rates of influx, tissue disposal and hepatic glucose production. The objective was to quantify rates of glucose influx and related fluxes as contributors to changes in PPG with GG and CPF additions to wheat-based flatbreads. In a randomised cross-over design, twelve healthy males consumed each of three different 13C-enriched meals: control flatbreads (C), or C incorporating 15 % CPF with either 2 % (GG2) or 4 % (GG4) GG. A dual isotope technique was used to determine the time to reach 50 % absorption of exogenous glucose (T 50 %abs, primary objective), rate of appearance of exogenous glucose (RaE), rate of appearance of total glucose (RaT), endogenous glucose production (EGP) and rate of disappearance of total glucose (RdT). Additional exploratory outcomes included PPG, insulin, glucose-dependent insulinotropic peptide and glucagon-like peptide 1, which were additionally measured over 4 h. Compared with C, GG2 and GG4 had no significant effect on T 50 %abs. However, GG4 significantly reduced 4-h AUC values for RaE, RaT, RdT and EGP, by 11, 14, 14 and 64 %, respectively, whereas GG2 showed minor effects. Effect sizes over 2 and 4 h were similar except for significantly greater reduction in EGP for GG4 at 2 h. In conclusion, a soluble fibre mix added to flatbreads only slightly reduced rates of glucose influx, but more substantially affected rates of postprandial disposal and hepatic glucose production.
Using the morphology of photoplethysmogram peaks to detect changes in posture.
Linder, Stephen P; Wendelken, Suzanne M; Wei, Edward; McGrath, Susan P
2006-06-01
The morphology of the pulsatile component of the photoplethysmogram (PPG) has been shown to vary with physiology, but changes in the morphology caused by the baroreflex response to orthostatic stress have not been investigated. Using two FDA approved Nonin pulse oximeters placed on the finger and ear, we monitored 11 subjects, for three trials each, as they stood from a supine position. Each cardiac cycle was automatically extracted from the PPG waveform and characterized using statistics corresponding to normalized peak width, instantaneous heart rate, and amplitude of the pulsatile component of the ear PPG. A nonparametric Wilcoxon rank sum test was then used to detect in real-time changes in these features with p < 0.01. In all 33 trials, the standing event was detected as an abrupt change in at least two of these features, with only one false alarm. In 26 trials, an abrupt change was detected in all three features, with no false alarms. An increase in the normalize peak width was detected before an increase in heart rate, and in 21 trials a peak in the feature was detected before or as standing commenced. During standing, the pulse rate always increases, and then amplitude of the ear PPG constricts by a factor of two or more. We hypothesis that the baroreflex first reduces the percentage of time blood flow is stagnant during the cardiac cycle, then increases the hear rate, and finally vasoconstricts the peripheral tissue in order to reestablishing a nominal blood pressure. These three features therefore can be used as a detector of the baroreflex response to changes in posture or other forms of blood volume sequestration.
The Postpharyngeal Gland: Specialized Organ for Lipid Nutrition in Leaf-Cutting Ants
Decio, Pâmela; Vieira, Alexsandro Santana; Dias, Nathalia Baptista; Palma, Mario Sergio; Bueno, Odair Correa
2016-01-01
There are several hypotheses about the possible functions of the postpharyngeal gland (PPG) in ants. The proposed functions include roles as cephalic or gastric caeca and diverticulum of the digestive tract, mixing of hydrocarbons, nestmate recognition, feeding larvae, and the accumulation of lipids inside this gland, whose origin is contradictory. The current study aimed to investigate the functions of these glands by examining the protein expression profile of the PPGs of Atta sexdens rubropilosa (Hymenoptera, Formicidae). Mated females received lipid supplementation and their glands were extracted and analyzed using a proteomic approach. The protocol used combined two-dimensional electrophoresis and shotgun strategies, followed by mass spectrometry. We also detected lipid β-oxidation by immunofluorescent marking of acyl-CoA dehydrogenase. Supplying ants with lipids elicited responses in the glandular cells of the PPG; these included increased expression of proteins related to defense mechanisms and signal transduction and reorganization of the cytoskeleton due to cell expansion. In addition, some proteins in PPG were overexpressed, especially those involved in lipid and energy metabolism. Part of the lipids may be reduced, used for the synthesis of fatty alcohol, transported to the hemolymph, or may be used as substrate for the synthesis of acetyl-CoA, which is oxidized to form molecules that drive oxidative phosphorylation and produce energy for cellular metabolic processes. These findings suggest that this organ is specialized for lipid nutrition of adult leaf-cutting ants and characterized like a of diverticulum foregut, with the ability to absorb, store, metabolize, and mobilize lipids to the hemolymph. However, we do not rule out that the PPG may have other functions in other species of ants. PMID:27149618
The Postpharyngeal Gland: Specialized Organ for Lipid Nutrition in Leaf-Cutting Ants.
Decio, Pâmela; Vieira, Alexsandro Santana; Dias, Nathalia Baptista; Palma, Mario Sergio; Bueno, Odair Correa
2016-01-01
There are several hypotheses about the possible functions of the postpharyngeal gland (PPG) in ants. The proposed functions include roles as cephalic or gastric caeca and diverticulum of the digestive tract, mixing of hydrocarbons, nestmate recognition, feeding larvae, and the accumulation of lipids inside this gland, whose origin is contradictory. The current study aimed to investigate the functions of these glands by examining the protein expression profile of the PPGs of Atta sexdens rubropilosa (Hymenoptera, Formicidae). Mated females received lipid supplementation and their glands were extracted and analyzed using a proteomic approach. The protocol used combined two-dimensional electrophoresis and shotgun strategies, followed by mass spectrometry. We also detected lipid β-oxidation by immunofluorescent marking of acyl-CoA dehydrogenase. Supplying ants with lipids elicited responses in the glandular cells of the PPG; these included increased expression of proteins related to defense mechanisms and signal transduction and reorganization of the cytoskeleton due to cell expansion. In addition, some proteins in PPG were overexpressed, especially those involved in lipid and energy metabolism. Part of the lipids may be reduced, used for the synthesis of fatty alcohol, transported to the hemolymph, or may be used as substrate for the synthesis of acetyl-CoA, which is oxidized to form molecules that drive oxidative phosphorylation and produce energy for cellular metabolic processes. These findings suggest that this organ is specialized for lipid nutrition of adult leaf-cutting ants and characterized like a of diverticulum foregut, with the ability to absorb, store, metabolize, and mobilize lipids to the hemolymph. However, we do not rule out that the PPG may have other functions in other species of ants.
Chen, Liangyou; Reisner, Andrew T; Gribok, Andrei; Reifman, Jaques
2010-11-01
It has been widely accepted that metrics related to respiration-induced waveform variation (RIWV) of the photoplethysmogram (PPG) have been associated with hypovolemia in mechanically ventilated patients and in controlled laboratory environments. In this retrospective study, we investigated if PPG RIWV metrics have diagnostic value for patients with acute hemorrhagic hypovolemia in the prehospital environment. Photoplethysmogram waveforms and basic vital signs were recorded in trauma patients during prehospital transport. Retrospectively, we used automated algorithms to select patient records with all five basic vital signs and 45 s or longer continuous, clean PPG segments. From these segments, we identified the onset and peak of individual heartbeats and computed waveform variations in the beats' peaks and amplitudes: (1) as the range between the maximum and the minimum (max-min) values and (2) as their interquartile range (IQR). We evaluated their receiver operating characteristic (ROC) curves for major hemorrhage. Separately, we tested whether RIWV metrics have potential independent information beyond basic vital signs by applying multivariate regression. In 344 patients, RIWV max-min yielded areas under the ROC curves (AUCs) not significantly better than a random AUC of 0.50. Respiration-induced waveform variation computed as IQR yielded ROC AUCs of 0.65 (95% confidence interval, 0.54-0.76) and of 0.64 (0.51-0.75), for peak and amplitude measures, respectively. The IQR metrics added independent information to basic vital signs (P < 0.05), but only moderately improved the overall AUC. Photoplethysmogram RIWV measured as IQR is preferable over max-min, and using PPG RIWV may enhance physiologic monitoring of spontaneously breathing patients outside strictly controlled laboratory environments.
Weir, Christopher J.; Rubio, Noah; Rabinovich, Roberto; Pinnock, Hilary; Hanley, Janet; McCloughan, Lucy; Drost, Ellen M.; Mantoani, Leandro C.; MacNee, William; McKinstry, Brian
2016-01-01
Introduction The Bland-Altman limits of agreement method is widely used to assess how well the measurements produced by two raters, devices or systems agree with each other. However, mixed effects versions of the method which take into account multiple sources of variability are less well described in the literature. We address the practical challenges of applying mixed effects limits of agreement to the comparison of several devices to measure respiratory rate in patients with chronic obstructive pulmonary disease (COPD). Methods Respiratory rate was measured in 21 people with a range of severity of COPD. Participants were asked to perform eleven different activities representative of daily life during a laboratory-based standardised protocol of 57 minutes. A mixed effects limits of agreement method was used to assess the agreement of five commercially available monitors (Camera, Photoplethysmography (PPG), Impedance, Accelerometer, and Chest-band) with the current gold standard device for measuring respiratory rate. Results Results produced using mixed effects limits of agreement were compared to results from a fixed effects method based on analysis of variance (ANOVA) and were found to be similar. The Accelerometer and Chest-band devices produced the narrowest limits of agreement (-8.63 to 4.27 and -9.99 to 6.80 respectively) with mean bias -2.18 and -1.60 breaths per minute. These devices also had the lowest within-participant and overall standard deviations (3.23 and 3.29 for Accelerometer and 4.17 and 4.28 for Chest-band respectively). Conclusions The mixed effects limits of agreement analysis enabled us to answer the question of which devices showed the strongest agreement with the gold standard device with respect to measuring respiratory rates. In particular, the estimated within-participant and overall standard deviations of the differences, which are easily obtainable from the mixed effects model results, gave a clear indication that the Accelerometer and Chest-band devices performed best. PMID:27973556
Cho, Dongrae; Ham, Jinsil; Oh, Jooyoung; Park, Jeanho; Kim, Sayup; Lee, Nak-Kyu; Lee, Boreom
2017-10-24
Virtual reality (VR) is a computer technique that creates an artificial environment composed of realistic images, sounds, and other sensations. Many researchers have used VR devices to generate various stimuli, and have utilized them to perform experiments or to provide treatment. In this study, the participants performed mental tasks using a VR device while physiological signals were measured: a photoplethysmogram (PPG), electrodermal activity (EDA), and skin temperature (SKT). In general, stress is an important factor that can influence the autonomic nervous system (ANS). Heart-rate variability (HRV) is known to be related to ANS activity, so we used an HRV derived from the PPG peak interval. In addition, the peak characteristics of the skin conductance (SC) from EDA and SKT variation can also reflect ANS activity; we utilized them as well. Then, we applied a kernel-based extreme-learning machine (K-ELM) to correctly classify the stress levels induced by the VR task to reflect five different levels of stress situations: baseline, mild stress, moderate stress, severe stress, and recovery. Twelve healthy subjects voluntarily participated in the study. Three physiological signals were measured in stress environment generated by VR device. As a result, the average classification accuracy was over 95% using K-ELM and the integrated feature (IT = HRV + SC + SKT). In addition, the proposed algorithm can embed a microcontroller chip since K-ELM algorithm have very short computation time. Therefore, a compact wearable device classifying stress levels using physiological signals can be developed.
Elgendi, Mohamed; Norton, Ian; Brearley, Matt; Abbott, Derek; Schuurmans, Dale
2013-01-01
Photoplethysmogram (PPG) monitoring is not only essential for critically ill patients in hospitals or at home, but also for those undergoing exercise testing. However, processing PPG signals measured after exercise is challenging, especially if the environment is hot and humid. In this paper, we propose a novel algorithm that can detect systolic peaks under challenging conditions, as in the case of emergency responders in tropical conditions. Accurate systolic-peak detection is an important first step for the analysis of heart rate variability. Algorithms based on local maxima-minima, first-derivative, and slope sum are evaluated, and a new algorithm is introduced to improve the detection rate. With 40 healthy subjects, the new algorithm demonstrates the highest overall detection accuracy (99.84% sensitivity, 99.89% positive predictivity). Existing algorithms, such as Billauer's, Li's and Zong's, have comparable although lower accuracy. However, the proposed algorithm presents an advantage for real-time applications by avoiding human intervention in threshold determination. For best performance, we show that a combination of two event-related moving averages with an offset threshold has an advantage in detecting systolic peaks, even in heat-stressed PPG signals.
Hickey, M; Samuels, N; Randive, N; Langford, R; Kyriacou, P A
2012-12-01
A new, continuous method of monitoring splanchnic organ oxygen saturation (SpO(2)) would make the early detection of inadequate tissue oxygenation feasible, reducing the risk of hypoperfusion, severe ischaemia, and, ultimately, death. In an attempt to provide such a device, a new fibre optic based reflectance pulse oximeter probe and processing system were developed followed by an in vivo evaluation of the technology on seventeen patients undergoing elective laparotomy. Photoplethysmographic (PPG) signals of good quality and high signal-to-noise ratio were obtained from the small bowel, large bowel, liver and stomach. Simultaneous peripheral PPG signals from the finger were also obtained for comparison purposes. Analysis of the amplitudes of all acquired PPG signals indicated much larger amplitudes for those signals obtained from splanchnic organs than those obtained from the finger. Estimated SpO(2) values for splanchnic organs showed good agreement with those obtained from the finger fibre optic probe and those obtained from a commercial device. These preliminary results suggest that a miniaturized 'indwelling' fibre optic sensor may be a suitable method for pre-operative and post-operative evaluation of splanchnic organ SpO(2) and their health. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Endogenous Hydrogen Sulfide Enhances Cell Proliferation of Human Gastric Cancer AGS Cells.
Sekiguchi, Fumiko; Sekimoto, Teruki; Ogura, Ayaka; Kawabata, Atsufumi
2016-01-01
Hydrogen sulfide (H2S), the third gasotransmitter, is endogenously generated by certain H2S synthesizing enzymes, including cystathionine-γ-lyase (CSE) and cystathionine-β-synthase (CBS) from L-cysteine in the mammalian body. Several studies have shown that endogenous and exogenous H2S affects the proliferation of cancer cells, although the effects of H2S appear to vary with cell type, being either promotive or suppressive. In the present study, we determined whether endogenously formed H2S regulates proliferation in human gastric cancer AGS cells. CSE, but not CBS, was expressed in AGS cells. CSE inhibitors, DL-propargylglycine (PPG) and β-cyano-L-alanine (BCA), significantly suppressed the proliferation of AGS cells in a concentration-dependent manner. CSE inhibitors did not increase lactate dehydrogenase (LDH) release in the same concentration range. The inhibitory effects of PPG and BCA on cell proliferation were reversed by repetitive application of NaHS, a donor of H2S. Interestingly, nuclear condensation and fragmentation were detected in AGS cells treated with PPG or BCA. These results suggest that endogenous H2S produced by CSE may contribute to the proliferation of gastric cancer AGS cells, most probably through anti-apoptotic actions.
Song, Hongjun; Wang, Yi; Pant, Kapil
2013-01-01
This paper presents an analytical study of the cross-stream diffusion of an analyte in a rectangular microchannel under combined electroosmotic flow (EOF) and pressure driven flow to investigate the heterogeneous transport behavior and spatially-dependent diffusion scaling law. An analytical model capable of accurately describing 3D steady-state convection-diffusion in microchannels with arbitrary aspect ratios is developed based on the assumption of the thin Electric Double Layer (EDL). The model is verified against high-fidelity numerical simulation in terms of flow velocity and analyte concentration profiles with excellent agreement (<0.5% relative error). An extensive parametric analysis is then undertaken to interrogate the effect of the combined flow velocity field on the transport behavior in both the positive pressure gradient (PPG) and negative pressure gradient (NPG) cases. For the first time, the evolution from the spindle-shaped concentration profile in the PPG case, via the stripe-shaped profile (pure EOF), and finally to the butterfly-shaped profile in the PPG case is obtained using the analytical model along with a quantitative depiction of the spatially-dependent diffusion layer thickness and scaling law across a wide range of the parameter space.
Song, Hongjun; Wang, Yi; Pant, Kapil
2012-01-01
This paper presents an analytical study of the cross-stream diffusion of an analyte in a rectangular microchannel under combined electroosmotic flow (EOF) and pressure driven flow to investigate the heterogeneous transport behavior and spatially-dependent diffusion scaling law. An analytical model capable of accurately describing 3D steady-state convection-diffusion in microchannels with arbitrary aspect ratios is developed based on the assumption of the thin Electric Double Layer (EDL). The model is verified against high-fidelity numerical simulation in terms of flow velocity and analyte concentration profiles with excellent agreement (<0.5% relative error). An extensive parametric analysis is then undertaken to interrogate the effect of the combined flow velocity field on the transport behavior in both the positive pressure gradient (PPG) and negative pressure gradient (NPG) cases. For the first time, the evolution from the spindle-shaped concentration profile in the PPG case, via the stripe-shaped profile (pure EOF), and finally to the butterfly-shaped profile in the PPG case is obtained using the analytical model along with a quantitative depiction of the spatially-dependent diffusion layer thickness and scaling law across a wide range of the parameter space. PMID:23554584
Nabeel, P M; Karthik, Srinivasa; Joseph, Jayaraj; Sivaprakasam, Mohanasankar
2017-07-01
We present a prototype design of dual element photoplethysmograph (PPG) probe along with associated measurement system for carotid local pulse wave velocity (PWV) evaluation in a non-invasive and continuous manner. The PPG probe consists of two identical sensing modules placed 23 mm apart. Simultaneously measured blood pulse waveforms from these arterial sites were processed and the pulse transit time delay was resolved using the developed application-specific software. The ability of developed PPG probe and associated measurement system to detect acute changes in carotid local PWV due to blood pressure (BP) variations was experimentally validated by an in-vivo study. Intra-subject carotid BP elevation was achieved by an upper arm cuff based occlusion, which offered a controlled way of local PWV escalation. The elevated carotid BP values were also recorded by a calibrated pressure tonometer prior to the study, and was used as a reference. A significant increment (1.0 - 2.6 m/s) in local PWV was observed and was proportional to the BP increment induced by the occlusive reactive hyperemia. Study results demonstrated the feasibility of real-time signal acquisition and reliable local PWV evaluation under normal and elevated BP conditions using the developed measurement system.
Jenkins, Nicholas T; Peña, Gustavo; Risco, Carlos; Barbosa, Carolina C; Vieira-Neto, Achilles; Galvão, Klibs N
2015-08-01
The objective was to identify a fat-to-protein ratio (FPR) cut-off to diagnose subclinical ketosis (SCK) and to evaluate the effect of propylene glycol (PPG) treatment of cows with high FPR. The optimized cut-off was > 1.42; sensitivity (Se) = 92%; specificity (Sp) = 65%. A cut-off > 1.5 was selected for the PPG trial for balanced Se-Sp. Fat-to-protein ratio cut-offs > 1.25, 1.35, 1.50, 1.60, and 1.70 resulted in Se-Sp of 100% to 49%, 96% to 59%, 75% to 78%, 33% to 90%, and 8% to 96%, respectively. The proportions of cows with FPR > 1.25, 1.35, 1.42, 1.50, 1.60, and 1.70 were 60%, 50%, 44%, 30%, 14%, and 6%, respectively. Incidences of clinical ketosis and milk yield were similar between cows that received 400 mL of PPG (n = 34) and control cows (n = 38). Prevalence of SCK at enrollment was 29.2%; therefore, FPR > 1.5 is not indicated for treatment. Lower cut-offs should be used for screening.
Jenkins, Nicholas T.; Peña, Gustavo; Risco, Carlos; Barbosa, Carolina C.; Vieira-Neto, Achilles; Galvão, Klibs N.
2015-01-01
The objective was to identify a fat-to-protein ratio (FPR) cut-off to diagnose subclinical ketosis (SCK) and to evaluate the effect of propylene glycol (PPG) treatment of cows with high FPR. The optimized cut-off was > 1.42; sensitivity (Se) = 92%; specificity (Sp) = 65%. A cut-off > 1.5 was selected for the PPG trial for balanced Se-Sp. Fat-to-protein ratio cut-offs > 1.25, 1.35, 1.50, 1.60, and 1.70 resulted in Se-Sp of 100% to 49%, 96% to 59%, 75% to 78%, 33% to 90%, and 8% to 96%, respectively. The proportions of cows with FPR > 1.25, 1.35, 1.42, 1.50, 1.60, and 1.70 were 60%, 50%, 44%, 30%, 14%, and 6%, respectively. Incidences of clinical ketosis and milk yield were similar between cows that received 400 mL of PPG (n = 34) and control cows (n = 38). Prevalence of SCK at enrollment was 29.2%; therefore, FPR > 1.5 is not indicated for treatment. Lower cut-offs should be used for screening. PMID:26246632
Broadband terahertz dynamics of propylene glycol monomer and oligomers
NASA Astrophysics Data System (ADS)
Koda, Shota; Mori, Tatsuya; Kojima, Seiji
2016-12-01
We investigated the broadband terahertz spectra (0.1-5.0 THz) of glass-forming liquids, propylene glycol (PG), its oligomers poly (propylene glycol)s (PPGs), and poly (propylene glycol) diglycidyl ether (PPG-de) using broadband terahertz time-domain spectroscopy and low-frequency Raman scattering. The numerical value of the dielectric loss at around 1.5 THz, which is the peak position of broad peaks in all samples, decreased as the molecular weight increased. Furthermore, the peak at around 1.5 THz is insensitive to the molecular weight. For PPGs, the side chain effect of the oligomer was observed in the terahertz region. Based on the experimental and calculation results for the PPGs and PPG-de, whose end groups are epoxy groups, the beginnings of the increases in the observed dielectric loss above 3.5 THz of the PPGs are assigned to the OH bending vibration. The higher value of the dielectric loss in the terahertz region for the PPG-de can be the tail of a broad peak located in the MHz region. The difference between the Raman susceptibility and dielectric loss reflects the difference in the observable molecular dynamics between the infrared and Raman spectroscopies.
Li, Zibiao; Zhang, Zhongxing; Liu, Kerh Li; Ni, Xiping; Li, Jun
2012-12-10
This paper reports the synthesis and characterization of new hyperbranched amphiphilic polyurethane multiblock copolymers consisting of poly(propylene glycol) (PPG), poly(ethylene glycol) (PEG), and polycaprolactone (PCL) segments as in situ thermogels. The hyperbranched poly(PPG/PEG/PCL urethane)s, termed as HBPEC copolymers, were synthesized from PPG-diol, PEG-diol, and PCL-triol by using 1,6-hexamethylene diisocyanate (HMDI) as a coupling agent. The compositions and structures of HBPEC copolymers were determined by GPC and 1H NMR spectroscopy. We carried out comparative studies of the new hyperbranched copolymers with their linear counterparts, the linear poly(PPG/PEG/PCL urethane) (LPEC) copolymer and Pluronic F127 PEG-PPG-PEG block copolymer, in terms of their self-assembly and aggregation behaviors and thermoresponsive properties. HBPEC copolymers were found to show thermoresponsive micelle formation and aggregation behaviors. Particularly, the lower critical solution temperature (LCST) of the copolymers was significantly affected by the copolymer architecture. HBPEC copolymers showed much lower LCST than LPEC, the linear counterpart. Our studies revealed that the effect of hyperbranch architecture was more prominent in the gelation of the copolymers. The aqueous solutions of HBPEC copolymers exhibited thermogelling behaviors at critical gelation concentrations (CGCs) ranging from 4.3 to 7.4 wt %. These values are much lower than those reported on other PCL-contained linear thermogelling copolymers and Pluronic F127 copolymer. In addition, the CGC of HBPEC copolymers is much lower than the control LPEC copolymer. More interestingly, at high temperatures, while LPEC and other linear thermogelling copolymers formed turbid sol, HBPEC formed a dehydrated gel. Our data suggest that these phenomena are caused by the hyperbranched structure of HBPEC copolymers, which could increase the interaction of copolymer branches and enhance the chain association through synergetic hydrogen bonding effect. The thermogelling behavior of HBPEC block copolymers was further evidenced by the 1H NMR molecular dynamic study and rheological study, which further support the above hypothesis. The hydrolytic degradation study showed that the HBPEC copolymer hydrogels are biodegradable under physiological conditions. Together with the good cell biocompatibility demonstrated by the cytotoxicity study, the new thermogelling copolymers reported in this paper could potentially be used as in situ-forming hydrogels for biomedical applications.
Scully, Christopher G; Selvaraj, Nandakumar; Romberg, Frederick W; Wardhan, Richa; Ryan, John; Florian, John P; Silverman, David G; Shelley, Kirk H; Chon, Ki H
2012-07-01
We designed this study to determine if 900 mL of blood withdrawal during spontaneous breathing in healthy volunteers could be detected by examining the time-varying spectral amplitude of the photoplethysmographic (PPG) waveform in the heart rate frequency band and/or in the breathing rate frequency band before significant changes occurred in heart rate or arterial blood pressure. We also identified the best PPG probe site for early detection of blood volume loss by testing ear, finger, and forehead sites. Eight subjects had 900 mL of blood withdrawn followed by reinfusion of 900 mL of blood. Physiological monitoring included PPG waveforms from ear, finger, and forehead probe sites, standard electrocardiogram, and standard blood pressure cuff measurements. The time-varying amplitude sequences in the heart rate frequency band and breathing rate frequency band present in the PPG waveform were extracted from high-resolution time-frequency spectra. These amplitudes were used as a parameter for blood loss detection. Heart rate and arterial blood pressure did not significantly change during the protocol. Using time-frequency analysis of the PPG waveform from ear, finger, and forehead probe sites, the amplitude signal extracted at the frequency corresponding to the heart rate significantly decreased when 900 mL of blood was withdrawn, relative to baseline (all P < 0.05); for the ear, the corresponding signal decreased when only 300 mL of blood was withdrawn. The mean percent decrease in the amplitude of the heart rate component at 900 mL blood loss relative to baseline was 45.2% (38.2%), 42.0% (29.2%), and 42.3% (30.5%) for ear, finger, and forehead probe sites, respectively, with the lower 95% confidence limit shown in parentheses. After 900 mL blood reinfusion, the amplitude signal at the heart rate frequency showed a recovery towards baseline. There was a clear separation of amplitude values at the heart rate frequency between baseline and 900 mL blood withdrawal. Specificity and sensitivity were both found to be 87.5% with 95% confidence intervals (47.4%, 99.7%) for ear PPG signals for a chosen threshold value that was optimized to separate the 2 clusters of amplitude values (baseline and blood loss) at the heart rate frequency. Meanwhile, no significant changes in the spectral amplitude in the frequency band corresponding to respiration were found. A time-frequency spectral method detected blood loss in spontaneously breathing subjects before the onset of significant changes in heart rate or blood pressure. Spectral amplitudes at the heart rate frequency band were found to significantly decrease during blood loss in spontaneously breathing subjects, whereas those at the breathing rate frequency band did not significantly change. This technique may serve as a valuable tool in intraoperative and trauma settings to detect and monitor hemorrhage.
The effects of optical sensor-tissue separation in endocavitary photoplethysmography.
Patel, Zaibaa; Thaha, Mohamed A; Kyriacou, Panayiotis A
2018-06-12
<i>Objective:</i> Intestinal anastomotic failure that occurs mainly due to ischaemia is a serious risk in colorectal cancer patients undergoing surgery. Surgeons continue to rely on subjective methods such as visual inspection to assess intestinal viability during surgery and there are no clinical tools to directly monitor viability postoperatively. A dual wavelength, reflectance optical sensor has been developed for continuous and dynamic monitoring of intestinal viability via the intestinal lumen. Maintaining direct contact between the sensor and the inner intestinal wall can be difficult in an intraluminal design, therefore impacting on signal acquisition and quality. This paper investigates the effect of direct contact versus variable distances between the sensor and the tissue surface of the buccal mucosa as a surrogate. <i>Approach:</i> The <i>in-vivo</i> study involved 20 healthy volunteers to measure the effect of optical sensor-tissue distances on the ability to acquire photoplethysmography signals and their quality. Signals were acquired from the buccal mucosa at five optical sensor-tissue distances. <i>Main results:</i> Distances between 0 mm (contact) to 5 mm were the most optimal, producing signals of high quality and signal-to-noise ratio, resulting in reliable estimations of the blood oxygen saturation. Distances exceeding 5 mm compromised the acquired signals, and were of poor quality, thereby unreliably estimating the blood oxygen saturation. <i>Significance:</i> The developed optical sensor proved to be reliable for acquiring photoplethysmography signals for cases where distances between the optical sensor-tissue may arise during the assessment of intraluminal intestinal viability. © 2018 Institute of Physics and Engineering in Medicine.
Picture Wall (Glass Structures)
NASA Technical Reports Server (NTRS)
1978-01-01
Photo shows a subway station in Toronto, Ontario, which is entirely glass-enclosed. The all-glass structure was made possible by a unique glazing concept developed by PPG Industries, Pittsburgh, Pennsylvania, one of the largest U.S. manufacturers of flat glass. In the TVS glazing system, transparent glass "fins" replace conventional vertical support members used to provide support for wind load resistance. For stiffening, silicone sealant bonds the fins to adjacent glass panels. At its glass research center near Pittsburgh, PPG Industries uses the NASTRAN computer program to analyze the stability of enclosures made entirely of glass. The company also uses NASTRAN to simulate stresses on large containers of molten glass and to analyze stress effects of solar heating on flat glass.
Feederism: an exaggeration of a normative mate selection preference?
Terry, Lesley L; Suschinsky, Kelly D; Lalumière, Martin L; Vasey, Paul L
2012-02-01
Quinsey and Lalumière (1995) suggested that some, if not most, paraphilias are exaggerated manifestations of more normative and functional mate selection preferences. The present study tested whether Feederism, a fat fetish focused on erotic eating, feeding, and gaining weight, is an exaggeration of a sexual arousal pattern commonly seen in the general population. Thirty participants (15 men and 15 women) recruited from the general population were assessed using penile plethysmography and vaginal photoplethysmography, respectively. None of the participants were self-identified Feeders or Feedees. Participants were shown sexual, neutral, and feeding still images while listening to audio recordings of sexual, neutral, and feeding stories. Participants did not genitally respond to feeding stimuli. However, both men and women subjectively rated feeding stimuli as more sexually arousing than neutral stimuli. We discuss the discordance between physiological and self-reported sexual arousal in the context of sex differences in sexual concordance and implications for future research.
A case of surgically treated peristomal pyoderma gangrenosum in a patient with rheumatoid arthritis
Khajehnoori, Masoomeh; O'Brien, Tim
2016-01-01
Peristomal pyoderma gangrenosum (PPG) is a rare subtype of pyoderma gangrenosum that is difficult to diagnose and treat. It is characterized by the rapid progression of painful necrotic ulcer surrounding an area of abdominal stoma. It is almost exclusively associated with inflammatory bowel disease even after bowel surgery and is associated with significant morbidity. Diagnosis of pyoderma gangrenosum is based on exclusion of other disorders replicating some of its clinical features and histopathological evidence. This is a case report of a 56-year-old lady with rheumatoid arthritis who presented with rapidly progressing abdominal ulcer 8 months after a Hartmanns procedure for perforated diverticulitis. The ulcer had formed a large cavity causing faecal filling in the dependent defect. The other causes of ulcer were excluded with negative histopathology, negative polymerase chain reaction for Mycobacterium ulcerans and negative acid fast bacillus (AFB) test. She was diagnosed with PPG which is routinely treated medically due to risk of setting off a second focus of pyoderma if surgically intervened. However due to increased risk of faecal peritonitis, it was decided to proceed with surgical debridement. This article will discuss the case in more detail and briefly discuss diagnosis and treatment options for PPG. PMID:27302499
Fukuda, Chihiro; Yahata, Chie; Kinoshita, Takuya; Watanabe, Takafumi; Tsukamoto, Hideo; Mochizuki, Akira
2017-10-01
It is well known that polyether-based copolymers have good blood compatibility, although many mechanisms have been proposed to explain their favorable performance. Our objective in carrying out the present study was to obtain a better understanding of the effect of the (poly)ether segment on blood compatibility. Therefore, we synthesized poly(propylene glycol) (PPG)-based initiators for atom transfer polymerization, where the number of propylene glycol (PG) units in the PPG (Pn(PG) was varied from 1 to 94. Methyl methacrylate (MMA) was polymerized using the initiators, resulting in the formation of polyMMAs with a PG-based ether part at the polymer terminal. We mainly investigated the effects of Pn(PG) on the surface properties and platelet compatibility of the PPG-polyMMA. X-ray photoelectron spectroscopy and surface contact angle (CA) analysis revealed the exposure of the PG units at the surface of the polymer. The platelet compatibility of the polymers was improved compared with a commercial polyMMA, even when Pn(PG) = 1. These results suggest that PG units have an important influence on favorable blood compatibility, regardless of the Pn(PG) value. We also investigated protein adsorption behavior in terms of the amount and deformation of fibrinogen adsorbed on the polymer surface.
Solar powered wrist worn acquisition system for continuous photoplethysmogram monitoring.
Dieffenderfer, James P; Beppler, Eric; Novak, Tristan; Whitmire, Eric; Jayakumar, Rochana; Randall, Clive; Qu, Weiguo; Rajagopalan, Ramakrishnan; Bozkurt, Alper
2014-01-01
We present a solar-powered, wireless, wrist-worn platform for continuous monitoring of physiological and environmental parameters during the activities of daily life. In this study, we demonstrate the capability to produce photoplethysmogram (PPG) signals using this platform. To adhere to a low power budget for solar-powering, a 574 nm green light source is used where the PPG from the radial artery would be obtained with minimal signal conditioning. The system incorporates two monocrystalline solar cells to charge the onboard 20 mAh lithium polymer battery. Bluetooth Low Energy (BLE) is used to tether the device to a smartphone that makes the phone an access point to a dedicated server for long term continuous storage of data. Two power management schemes have been proposed depending on the availability of solar energy. In low light situations, if the battery is low, the device obtains a 5-second PPG waveform every minute to consume an average power of 0.57 mW. In scenarios where the battery is at a sustainable voltage, the device is set to enter its normal 30 Hz acquisition mode, consuming around 13.7 mW. We also present our efforts towards improving the charge storage capacity of our on-board super-capacitor.
Abe, Masanori; Higuchi, Terumi; Moriuchi, Masari; Okamura, Masahiro; Tei, Ritsukou; Nagura, Chinami; Takashima, Hiroyuki; Kikuchi, Fumito; Tomita, Hyoe; Okada, Kazuyoshi
2016-06-01
Saxagliptin is a dipeptidyl peptidase-4 inhibitor that was approved in Japan for the treatment of type 2 diabetes in 2013. We examined its efficacy and safety in Japanese hemodialysis patients with diabetic nephropathy. In this prospective, open-label, parallel-group study, Japanese hemodialysis patients were randomized to receive either oral saxagliptin (2.5mg/day) or usual care (control group) for 24weeks. Before randomization, patients received fixed doses of conventional antidiabetic drugs (oral drugs and/or insulin) for 8weeks; these drugs were continued during the study. Endpoints included changes in glycated albumin (GA), hemoglobin A1c (HbA1c), postprandial plasma glucose (PPG), and adverse events. Both groups included 41 patients. Mean GA, HbA1c, and PPG decreased significantly in the saxagliptin group (-3.4%, -0.6% [-7mmol/mol], and -38.3mg/dL, respectively; all P<0.0001) but not in the control group (0%, -0.1% [-1mmol/mol], and -3.7mg/dL, respectively) (P<0.0001, P<0.001, and P<0.0001, respectively). In saxagliptin-treated patients, the reduction in GA was significantly greater when saxagliptin was administered as monotherapy than in combination therapy (-4.2% vs. -3.0%, P=0.012) despite similar baseline values (24.5% vs. 23.3%). Reductions in GA, HbA1c, and PPG were greater in patients whose baseline values exceeded the median (23.8% for GA, 6.6% for HbA1c, and 180mg/dL for PPG). There were no adverse events associated with saxagliptin. Saxagliptin (2.5mg/day) was effective and well tolerated when used as monotherapy or combined with other antidiabetic drugs in Japanese hemodialysis patients with type 2 diabetes. UMIN000018445. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
De Souza, Leanne R; Jenkins, Alexandra L; Jovanovski, Elena; Rahelić, Dario; Vuksan, Vladimir
2015-01-15
Ginsenosides are the proposed bioactive constituent of ginseng, especially for the attenuation of postprandial glycemia (PPG). The efficacious proportion of total and specific ginsenosides, remains unknown. Alcohol extraction of whole ginseng root can be used to selectively manipulate the ginsenoside profile with increasing alcohol concentrations producing high yields of total ginsenosides and varying their individual proportions. We aimed to compare the acute efficacy of different ethanol-extraction preparations of American ginseng (AG) and Korean red ginseng (KRG), with their whole-root origins, on PPG and insulin parameters in healthy adults. Following an overnight fast, 13 healthy individuals (Gender: 5M:8F, with mean ± SD, age: 28.9 ± 9.2 years, BMI: 26.3 ± 2.7 kg/m(2) and fasting plasma glucose: 4.21 ± 0.04 mmol/L) randomly received 3g of each of the following 10 different ginseng treatments on separate visits: whole root KRG and AG; 30%, 50% or 70% ethanol extracts of KRG and AG and 2 cornstarch placebos. Treatments were consumed 40 min prior to a 50 g oral glucose challenge test with capillary blood samples collected at baseline, 15, 30, 45, 60, 90 and 120 min. Insulin samples were collected at 0, 30, 60 and 120 min. There was no difference in attenuation of PPG among the tested ginseng preparations. Measures of Insulin Sensitivity Index (ISI) showed increased insulin sensitivity (IS) with KRG-30% and AG-50% extracts compared to placebo (p<0.05). The insulin sensitizing effects of KRG-30% and AG-50% extracts suggest that other root parts, including other ginsenosides not typically measured, may influence PPG and insulin parameters. There is potential for AG and KRG extracts to modulate IS, an independent predictor of type 2 diabetes. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Guo, Tao; Cao, Zhengtao; Zhang, Zhengbo; Li, Deyu; Yu, Mengsun
2015-08-05
Pulse oxygen saturation (SpO2) is an important parameter for healthcare, and wearable sensors and systems for SpO2 monitoring have become increasingly popular. The aim of this paper is to develop a novel SpO2 monitoring system, which detects photoplethysmographic (PPG) signals at hypothenar with a reflection-mode sensor embedded into a glove. A special photo-detector section was designed with two photodiodes arranged symmetrically to the red and infrared light-emitting diodes (LED) to enhance the signal quality. The reflective sensor was placed in a soft silicon substrate sewn in a glove to fit the surface of the hypothenar. To lower the power consumption, the LED driving current was reduced and energy-efficient electronic components were applied. The performance for PPG signal detection and SpO2 monitoring was evaluated by human hypoxia experiments. Accelerometer-based adaptive noise cancellation (ANC) methods applying the least mean squares (LMS) and recursive least squares (RLS) algorithms were studied to suppress motion artifact. A total of 20 subjects participated in the hypoxia experiment. The degree of comfort for wearing this system was accepted by them. The PPG signals were detected effectively at SpO2 levels from about 100-70%. The experiment validated the accuracy of the system was 2.34%, compared to the invasive measurements. Both the LMS and RLS algorithms improved the performance during motion. The total current consumed by the system was only 8 mA. It is feasible to detect PPG signal and monitor SpO2 at the location of hypothenar. This novel system can achieve reliable SpO2 measurements at different SpO2 levels and on different individuals. The system is light-weighted, easy to wear and power-saving. It has the potential to be a solution for wearable monitoring, although more work should be conducted to improve the motion-resistant performance significantly.
Fysekidis, Marinos; Cosson, Emmanuel; Banu, Isabela; Duteil, Régine; Cyrille, Chantal; Valensi, Paul
2014-12-01
The contribution of postprandial glycemia (PPG) to hyperglycemia has been shown to decrease as HbA1c increased in type 2 diabetic patients. This study aimed at examining, in a series of overweight/obese patients without known glycemic disorder, the contribution of PPG to a "relative" hyperglycemia (glucose values≥5.5 mmol/L) and the presence of glycemic variability according to HbA1c levels. Seventy overweight/obese inpatients (body mass index 35.2±6.8 kg/m2) without known glycemic disorder were included. Participants were classified according to an oral glucose tolerance test (according to the American Diabetes Association criteria) as patients with normoglycemia (n=33), with intermediate hyperglycemia (n=24) or diabetes (n=13). They were separated into HbA1c quartiles (Q1 to Q4). A 24 hour continuous glucose monitoring was used under a 1800 kcal diet and minimal physical activity. We assessed PPG contribution (3 hour period after each meal) to the "relative" 24 hour hyperglycemia (glucose values ≥5.5 mmol/L); the remaining time was considered as the fasting/post-absorptive period. HbA1c range was from 5.1% to 7.4% (32 to 57 mmol/mmol). From the lowest to the highest HbA1c quartile, the area under the curve (AUC) for the "relative" hyperglycemia presented a 17-fold increase for the fasting/post-absorptive (p<0.001) period and a 7-fold increase postprandially (p<0.001). The percent of PPG contribution to the "relative" hyperglycemia was calculated with the following formula [100×(postprandial 3 hour AUC-3 h AUC for a constant 5.5 mmol/L glycemia)/(total 24 h AUC-24 h AUC for constant 5. 5 mmol/L glycemia)] and decreased from Q1 to Q4 of HbA1c (81.2%, 66%, 65.8%, 57%; p<0.001). Increasing HbA1c quartiles were associated with higher daily mean blood glucose level (p<0.001) and higher levels of daily glucose variability indices, including mean amplitude of glycemic excursions (p<0.01). In overweight/obese patients, HbA1c was associated with lower PPG contribution to "relative" hyperglycemia and greater glycemic variability. The present findings support the importance of postprandial period in glycemic exposure even before the appearance of diabetes. Copyright © 2014 Elsevier Inc. All rights reserved.
Transitions in pregnancy planning in women recruited for a large prospective cohort study.
Luderer, U; Li, T; Fine, J P; Hamman, R F; Stanford, J B; Baker, D
2017-06-01
Do the rates at which women transition among different intensities of pregnancy planning vary with age, marital status and race/ethnicity? Rates of transition from low or moderate pregnancy probability groups (PPGs) to higher PPGs vary by age, marital status and race/ethnicity. The design of prospective studies of the effects of pre- and peri-conception exposures on fecundity, pregnancy and children's health is challenging because at any specific time only a small percentage of reproductive age women is attempting to conceive. To our knowledge, there has been no population-based, prospective study that repeatedly assessed pregnancy planning, which included women who were not already planning pregnancy at enrollment and whose ages spanned the female reproductive age range. A longitudinal study was carried out that repeatedly assessed pregnancy probability in 12 916 women for up to 21 months from January 2009 to September 2010. We analyzed data from the National Children's Study Vanguard Study, a pilot study for a large-scale epidemiological birth cohort study of children and their parents. During the Vanguard Study, investigators followed population-based samples of reproductive age women in each of seven geographically dispersed and diverse study locations over time to identify when they sought to become pregnant, providing a unique opportunity to prospectively assess changes in pregnancy planning in a large sample of US women. At study entry and each follow-up contact, which occurred at 1, 3 or 6 month intervals depending on PPG, a questionnaire was used to assess behavior dimensions of pregnancy planning to assign women to low, moderate, high non-tryer and high tryer PPGs. Crude rates of pregnancy increased with higher assigned PPG, validating the utility of the instrument. The initial PPG and probabilities of transitioning from low or moderate PPG to higher PPG or pregnancy varied with age, marital status and race/ethnicity. Women aged 25 to <35 years had shorter times to transition to higher PPGs or to pregnant compared with women <25 years. Women who were not currently married had longer times to transition from any initial PPG to pregnant, high tryer or high non-tryer status than currently married women. Non-Hispanic Black (NHB) and Hispanic women had shorter time to transition from low or moderate to high non-tryer than non-Hispanic White (NHW) women. NHB women also had shorter time to transition from low to high tryer than NHW women. High tryers are more likely to be aged 25 to <30 years, to be married, and to be Hispanic, NHB or other race/ethnicity than women in the low PPG. Loss to follow-up varied by age, marital status and race/ethnicity. Although weights were not developed for the Vanguard study, the self-weighting design minimizes the bias of unweighted analysis. Nonetheless, the SEs for some estimates may be under-estimated. Our results show that demographic characteristics are strong predictors of women's behaviors toward pregnancy. The results further show that frequent follow-up assessments of pregnancy planning behavior in large numbers of women are required to recruit an unbiased sample of preconception women. These findings will be useful to investigators designing prospective studies of fecundability, pregnancy outcomes and children's health. National Institutes of Health (contracts N01-HD53414, N01-HD63416, N01-HD53410, N01-HD53415, N01-HD53396, N01-HD53413 and N01-HD-53411; grant R21 ES016846) and by the University of California Irvine Center for Occupational and Environmental Health. No competing interests. None. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com
Full scattering profile for detecting physiological tissue properties
NASA Astrophysics Data System (ADS)
Duadi, Hamootal; Fixler, Dror
2017-02-01
Light reflectance and transmission from soft tissue has been utilized in noninvasive clinical measurement devices such as the photoplethysmograph (PPG) and reflectance pulse oximeter. Most methods of near infrared (NIR) spectroscopy focus on the volume reflectance from a semi-infinite sample, while very few measure transmission. We have previously shown that examining the full scattering profile (FSP), which is the angular distribution of exiting photons, provides more comprehensive information when measuring from a cylindrical tissue, such as earlobe, fingertip and pinched tissue. Our hypothesis is that the change in blood vessel diameter is more significant than the change in optical properties. The findings of this work demonstrate a realistic model for optical tissue measurements such as NIR spectroscopy, PPG and pulse oximetery.
New Aqueous Binders for Lithium-ion Batteries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jansen, Andrew N.; Krumdick, Gregory K.; Trask, Stephen E.
2016-12-22
This final report summarizes the research effort of the CRADA between PPG Industries and Argonne National Laboratory (CRADA # C1400501 and Amendment 1 - ACK 85C11, Rev. 1), and completes the requirements of Task #5 in the CRADA. The results from Argonne represent a combined effort between the MERF and CAMP Facility (Materials Engineering Research Facility and the Cell Analysis, Modeling and Prototyping Facility). The key points of this report can be briefly summarized as: The multicomponent aqueous binder for NCM cathodes developed by PPG shows promising results when used on the CAMP Facility’s pilot-scale coater; NCM523 cathode electrodes exposedmore » to water exhibit a voltage anomaly in the first two formation cycles that appears to have little effect on the material capacity, but needs to be explored further; the experimental LFP electrode produced by PPG does cycle electrochemically, but with reduced capacity and an uncharacteristic voltage profile; there is no obvious correlation between the pH and zeta-potential of materials that are commonly used in the lithium-ion battery; lithium ions are more readily dissolved out of NCM523 by water than the transition metals (by two orders of magnitude), and suggests that the plating bath may need to be spiked with a lithium salt; the approach of creating sub-micron size NCM523 particles via ball milling results in a cathode material with poor electrochemical performance.« less
Lixisenatide plus basal insulin in patients with type 2 diabetes mellitus: a meta-analysis.
Charbonnel, Bernard; Bertolini, Monica; Tinahones, Francisco J; Domingo, Manuel Puig; Davies, Melanie
2014-01-01
The efficacy of the once-daily prandial GLP-1 receptor agonist lixisenatide plus basal insulin in T2DM was assessed by pooling results of phase III trials. A meta-analysis was performed of results from three trials in the GetGoal clinical program concerning lixisenatide or placebo plus basal insulin with/without OADs. The primary endpoint was change in HbA1c from baseline to week 24. Secondary endpoints were change in PPG, FPG, insulin dose, and weight from baseline to week 24. Hypoglycemia rates and several composite endpoints were assessed. Lixisenatide plus basal insulin was significantly more effective than basal insulin alone at reducing HbA1c at 24 weeks. Composite and secondary endpoints were improved significantly with lixisenatide plus basal insulin, with the exception of FPG, which showed no significant difference between the groups. Lixisenatide plus basal insulin was associated with an increased incidence of hypoglycemia versus basal insulin alone. Lixisenatide plus basal insulin resulted in significant improvement in glycemic control versus basal insulin alone, particularly in terms of controlling PPG. Prandial lixisenatide in combination with basal insulin is a suitable option for treatment intensification in patients with T2DM insufficiently controlled with basal insulin, as these agents have complementary effects on PPG and FPG, respectively. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.
Full scattering profile of tissues with elliptical cross sections
NASA Astrophysics Data System (ADS)
Duadi, H.; Feder, I.; Fixler, D.
2018-02-01
Light reflectance and transmission from soft tissue has been utilized in noninvasive clinical measurement devices such as the photoplethysmograph (PPG) and reflectance pulse oximeter. Most methods of near infrared (NIR) spectroscopy focus on the volume reflectance from a semi-infinite sample, while very few measure transmission. However, since PPG and pulse oximetry are usually measured on tissue such as earlobe, fingertip, lip and pinched tissue, we propose examining the full scattering profile (FSP), which is the angular distribution of exiting photons. The FSP provides more comprehensive information when measuring from a cylindrical tissue. In our work we discovered a unique point, that we named the iso-pathlength (IPL) point, which is not dependent on changes in the reduced scattering coefficient (µs'). This IPL point was observed both in Monte Carlo (MC) simulation and in experimental tissue mimicking phantoms. The angle corresponding to this IPL point depends only on the tissue geometry. In the case of cylindrical tissues this point linearly depends on the tissue diameter. Since the target tissues for clinically physiological measuring are not a perfect cylinder, in this work we will examine how the change in the tissue cross section geometry influences the FSP and the IPL point. We used a MC simulation to compare a circular to an elliptic tissue cross section. The IPL point can serve as a self-calibration point for optical tissue measurements such as NIR spectroscopy, PPG and pulse oximetery.
Islam, Mohammad Tariqul; Tanvir Ahmed, Sk.; Zabir, Ishmam; Shahnaz, Celia
2018-01-01
Photoplethysmographic (PPG) signal is getting popularity for monitoring heart rate in wearable devices because of simplicity of construction and low cost of the sensor. The task becomes very difficult due to the presence of various motion artefacts. In this study, an algorithm based on cascade and parallel combination (CPC) of adaptive filters is proposed in order to reduce the effect of motion artefacts. First, preliminary noise reduction is performed by averaging two channel PPG signals. Next in order to reduce the effect of motion artefacts, a cascaded filter structure consisting of three cascaded adaptive filter blocks is developed where three-channel accelerometer signals are used as references to motion artefacts. To further reduce the affect of noise, a scheme based on convex combination of two such cascaded adaptive noise cancelers is introduced, where two widely used adaptive filters namely recursive least squares and least mean squares filters are employed. Heart rates are estimated from the noise reduced PPG signal in spectral domain. Finally, an efficient heart rate tracking algorithm is designed based on the nature of the heart rate variability. The performance of the proposed CPC method is tested on a widely used public database. It is found that the proposed method offers very low estimation error and a smooth heart rate tracking with simple algorithmic approach. PMID:29515812
NASA Astrophysics Data System (ADS)
Poutsma, John C.; Martens, Jonathan; Oomens, Jos; Maitre, Phillipe; Steinmetz, Vincent; Bernier, Matthew; Jia, Mengxuan; Wysocki, Vicki
2017-07-01
Infrared multiple-photon dissociation (IRMPD) action spectroscopy was performed on the b2 + fragment ion from the protonated PPG tripeptide. Comparison of the experimental infrared spectrum with computed spectra for both oxazolone and diketopiperazine structures indicates that the majority of the fragment ion population has an oxazolone structure with the remainder having a diketopiperazine structure. This result is in contrast with a recent study of the IRMPD action spectrum of the PP b2 + fragment ion from PPP, which was found to be nearly 100% diketopiperazine (Martens et al. Int. J. Mass Spectrom. 2015, 377, 179). The diketopiperazine b2 + ion is thermodynamically more stable than the oxazolone but normally requires a trans/cis peptide bond isomerization in the dissociating peptide. Martens et al. showed through IRMPD action spectroscopy that the PPP precursor ion was in a conformation in which the first peptide bond is already in the cis conformation and thus it was energetically favorable to form the thermodynamically-favored diketopiperazine b2 + ion. In the present case, solution-phase NMR spectroscopy and gas-phase IRMPD action spectroscopy show that the PPG precursor ion has its first amide bond in a trans configuration suggesting that the third residue is playing an important role in both the structure of the peptide and the associated ring-closure barriers for oxazolone and diketopiperazine formation.
Dynamic time warping and machine learning for signal quality assessment of pulsatile signals.
Li, Q; Clifford, G D
2012-09-01
In this work, we describe a beat-by-beat method for assessing the clinical utility of pulsatile waveforms, primarily recorded from cardiovascular blood volume or pressure changes, concentrating on the photoplethysmogram (PPG). Physiological blood flow is nonstationary, with pulses changing in height, width and morphology due to changes in heart rate, cardiac output, sensor type and hardware or software pre-processing requirements. Moreover, considerable inter-individual and sensor-location variability exists. Simple template matching methods are therefore inappropriate, and a patient-specific adaptive initialization is therefore required. We introduce dynamic time warping to stretch each beat to match a running template and combine it with several other features related to signal quality, including correlation and the percentage of the beat that appeared to be clipped. The features were then presented to a multi-layer perceptron neural network to learn the relationships between the parameters in the presence of good- and bad-quality pulses. An expert-labeled database of 1055 segments of PPG, each 6 s long, recorded from 104 separate critical care admissions during both normal and verified arrhythmic events, was used to train and test our algorithms. An accuracy of 97.5% on the training set and 95.2% on test set was found. The algorithm could be deployed as a stand-alone signal quality assessment algorithm for vetting the clinical utility of PPG traces or any similar quasi-periodic signal.
Barrera, Jason G; Jones, Kenneth R; Herman, James P; D'Alessio, David A; Woods, Stephen C; Seeley, Randy J
2011-03-09
Central administration of glucagon-like peptide-1 (GLP-1) causes a dose-dependent reduction in food intake, but the role of endogenous CNS GLP-1 in the regulation of energy balance remains unclear. Here, we tested the hypothesis that CNS GLP-1 activity is required for normal energy balance by using two independent methods to achieve chronic CNS GLP-1 loss of function in rats. Specifically, lentiviral-mediated expression of RNA interference was used to knock down nucleus of the solitary tract (NTS) preproglucagon (PPG), and chronic intracerebroventricular (ICV) infusion of the GLP-1 receptor (GLP-1r) antagonist exendin (9-39) (Ex9) was used to block CNS GLP-1r. NTS PPG knockdown caused hyperphagia and exacerbated high-fat diet (HFD)-induced fat accumulation and glucose intolerance. Moreover, in control virus-treated rats fed the HFD, NTS PPG expression levels correlated positively with fat mass. Chronic ICV Ex9 also caused hyperphagia; however, increased fat accumulation and glucose intolerance occurred regardless of diet. Collectively, these data provide the strongest evidence to date that CNS GLP-1 plays a physiologic role in the long-term regulation of energy balance. Moreover, they suggest that this role is distinct from that of circulating GLP-1 as a short-term satiation signal. Therefore, it may be possible to tailor GLP-1-based therapies for the prevention and/or treatment of obesity.
A Gaussian Model-Based Probabilistic Approach for Pulse Transit Time Estimation.
Jang, Dae-Geun; Park, Seung-Hun; Hahn, Minsoo
2016-01-01
In this paper, we propose a new probabilistic approach to pulse transit time (PTT) estimation using a Gaussian distribution model. It is motivated basically by the hypothesis that PTTs normalized by RR intervals follow the Gaussian distribution. To verify the hypothesis, we demonstrate the effects of arterial compliance on the normalized PTTs using the Moens-Korteweg equation. Furthermore, we observe a Gaussian distribution of the normalized PTTs on real data. In order to estimate the PTT using the hypothesis, we first assumed that R-waves in the electrocardiogram (ECG) can be correctly identified. The R-waves limit searching ranges to detect pulse peaks in the photoplethysmogram (PPG) and to synchronize the results with cardiac beats--i.e., the peaks of the PPG are extracted within the corresponding RR interval of the ECG as pulse peak candidates. Their probabilities of being the actual pulse peak are then calculated using a Gaussian probability function. The parameters of the Gaussian function are automatically updated when a new pulse peak is identified. This update makes the probability function adaptive to variations of cardiac cycles. Finally, the pulse peak is identified as the candidate with the highest probability. The proposed approach is tested on a database where ECG and PPG waveforms are collected simultaneously during the submaximal bicycle ergometer exercise test. The results are promising, suggesting that the method provides a simple but more accurate PTT estimation in real applications.
NASA Astrophysics Data System (ADS)
Yang, Fenglei; Hu, Sijung; Ma, Xiaoyun; Hassan, Harnani; Wei, Dongqing
2015-03-01
Spontaneous expression is associated with physiological states, i.e., heart rate, respiration, oxygen saturation (SpO2%), and heart rate variability (HRV). There have yet not sufficient efforts to explore correlation of physiological change and spontaneous expression. This study aims to study how spontaneous expression is associated with physiological changes with an approved protocol or through the videos provided from Denver Intensity of Spontaneous Facial Action Database. Not like a posed expression, motion artefact in spontaneous expression is one of evitable challenges to be overcome in the study. To obtain a physiological signs from a region of interest (ROI), a new engineering approach is being developed with an artefact-reduction method consolidated 3D active appearance model (AAM) based track, affine transformation based alignment with opto-physiological mode based imaging photoplethysmography. Also, a statistical association spaces is being used to interpret correlation of spontaneous expressions and physiological states including their probability densities by means of Gaussian Mixture Model. The present work is revealing a new avenue of study associations of spontaneous expressions and physiological states with its prospect of applications on physiological and psychological assessment.
Kim, Jongpal; Kim, Jihoon; Ko, Hyoungho
2015-12-31
To overcome light interference, including a large DC offset and ambient light variation, a robust photoplethysmogram (PPG) readout chip is fabricated using a 0.13-μm complementary metal-oxide-semiconductor (CMOS) process. Against the large DC offset, a saturation detection and current feedback circuit is proposed to compensate for an offset current of up to 30 μA. For robustness against optical path variation, an automatic emitted light compensation method is adopted. To prevent ambient light interference, an alternating sampling and charge redistribution technique is also proposed. In the proposed technique, no additional power is consumed, and only three differential switches and one capacitor are required. The PPG readout channel consumes 26.4 μW and has an input referred current noise of 260 pArms.
Kim, Jongpal; Kim, Jihoon; Ko, Hyoungho
2015-01-01
To overcome light interference, including a large DC offset and ambient light variation, a robust photoplethysmogram (PPG) readout chip is fabricated using a 0.13-μm complementary metal–oxide–semiconductor (CMOS) process. Against the large DC offset, a saturation detection and current feedback circuit is proposed to compensate for an offset current of up to 30 μA. For robustness against optical path variation, an automatic emitted light compensation method is adopted. To prevent ambient light interference, an alternating sampling and charge redistribution technique is also proposed. In the proposed technique, no additional power is consumed, and only three differential switches and one capacitor are required. The PPG readout channel consumes 26.4 μW and has an input referred current noise of 260 pArms. PMID:26729122
NASA Astrophysics Data System (ADS)
Alizadeh, Azar; Ashe, Jeffrey; Misner, Matthew; Yang, Yanzhe; Zhong, Sheng; Yin, Ming; Brewer, Joleyn; Karp, Jason
2013-03-01
Many previous efforts to modify patient monitors for remote or wearable use have suffered from high cost, poor performance, and low medical acceptance. A new technology approach is needed to enable these clinical benefits and to satisfy challenging economic, clinical, and user-acceptance criteria. Here, we present results on our initial efforts aimed at designing and building a prototype multi-wavelength arrayed photoplethysmograph (PPG) by using magnetically directed self-assembly (MDSA). We will discuss novel approaches in magnetic nanomaterial design, synthesis and deposition to enable MDSA based manufacturing. We will also demonstrate that multiple devices can be deposited through heterogeneous MDSA. The novel MDSA technology could make such PPG sensors a reality. This effort is sponsored by the Department of the Army under award W81XWH1110833
Derosa, Giuseppe; Salvadeo, Sibilla A T; D'Angelo, Angela; Ferrari, Ilaria; Mereu, Roberto; Palumbo, Ilaria; Maffioli, Pamela; Randazzo, Sabrina; Cicero, Arrigo F G
2009-03-01
To compare the metabolic effects of acarbose and repaglinide in type 2 diabetic patients who are being treated with a sulphonylurea-metformin combination therapy. The primary endpoint of the study was to evaluate which add-on treatment between acarbose and repaglinide is more efficacious in reducing PPG. The second endpoint was to evaluate which of these two treatment is more efficacious in the global management of glucose homeostasis in the enrolled patients. After a 4-week run-in period with a sulphonylurea-metformin combination, 103 patients were randomised to receive in addition either repaglinide, up to 6 mg/day (2 mg three times a day) or acarbose, up to 300 mg/day (100 mg three times a day) with forced titration (independently of their glycaemic control, unless side-effects developed due to the drug dosage) for 15 weeks. The treatment was then crossed-over for further 12 weeks until the 27th week. We assessed body mass index (BMI), glycosylated haemoglobin (HbA(1c)), fasting plasma glucose (FPG), postprandial plasma glucose (PPG), fasting plasma insulin (FPI), postprandial plasma insulin (PPI), homeostatic model assessment (HOMA) index, systolic blood pressure (SBP), diastolic blood pressure (DBP), total cholesterol (TC), low-density lipoprotein cholesterol (LDL-C), high-density lipoprotein cholesterol (HDL-C) and triglycerides (Tg), at baseline and at 1, 2, 15 and 27 weeks of treatment. Seven patients did not complete the study, comprising one patient who was lost to follow-up and a further six through side-effects (two in week 1, one in week 15 and three after cross-over) Side-effects were classified as nausea (one in acarbose group), gastrointestinal events (four in acarbose group), and hypoglycaemia (one in repaglinide group). After 15 weeks of therapy, the repaglinide-treated patients experienced a significant decrease in HbA(1c) (-1.1%, p < 0.05), FPG (-9.5%, p < 0.05), and PPG (-14.9%, p < 0.05), when compared to the baseline values. However, the same treatment was associated with a significant increase in body weight (+2.3%, p < 0.05), BMI (+3.3%, p < 0.05) and FPI (+22.5%, p < 0.05); The increase was reversed during the cross-over phase. After 15 weeks of therapy, the acarbose-treated patients experienced a significant decrease in body weight (-1.9%, p < 0.05), BMI (-4.1%, p < 0.05), HbA(1c) (-1.4%, p < 0.05), FPG (-10.7%, p < 0.05), PPG (-16.2%, p < 0.05), FPI (-16.1%, p < 0.05), PPI (-26.9%, p < 0.05), HOMA index (-30.1%, p < 0.05), when compared to the baseline values. All these changes were reversed during the cross-over study phase, except those relating to HbA(1c), FPG and PPG. The only changes that significantly differed when directly comparing acarbose- and repaglinide-treated patients were those relating to FPI (-16.1% vs. +22.5%, respectively, p < 0.05) and HOMA index (-30.1% vs. +2.7%, p < 0.05). In addition from having a similar effect to repaglinide on PPG, acarbose appeared to have a more comprehensive positive effect on glucose metabolism compared to repaglinide in this relatively small sample of type 2 diabetic patients when used as add-on therapy to sulphonylureas and metformin.
Clinical Validation of Heart Rate Apps: Mixed-Methods Evaluation Study
Stans, Jelle; Mortelmans, Christophe; Van Haelst, Ruth; Van Schelvergem, Gertjan; Pelckmans, Caroline; Smeets, Christophe JP; Lanssens, Dorien; De Cannière, Hélène; Storms, Valerie; Thijs, Inge M; Vaes, Bert; Vandervoort, Pieter M
2017-01-01
Background Photoplethysmography (PPG) is a proven way to measure heart rate (HR). This technology is already available in smartphones, which allows measuring HR only by using the smartphone. Given the widespread availability of smartphones, this creates a scalable way to enable mobile HR monitoring. An essential precondition is that these technologies are as reliable and accurate as the current clinical (gold) standards. At this moment, there is no consensus on a gold standard method for the validation of HR apps. This results in different validation processes that do not always reflect the veracious outcome of comparison. Objective The aim of this paper was to investigate and describe the necessary elements in validating and comparing HR apps versus standard technology. Methods The FibriCheck (Qompium) app was used in two separate prospective nonrandomized studies. In the first study, the HR of the FibriCheck app was consecutively compared with 2 different Food and Drug Administration (FDA)-cleared HR devices: the Nonin oximeter and the AliveCor Mobile ECG. In the second study, a next step in validation was performed by comparing the beat-to-beat intervals of the FibriCheck app to a synchronized ECG recording. Results In the first study, the HR (BPM, beats per minute) of 88 random subjects consecutively measured with the 3 devices showed a correlation coefficient of .834 between FibriCheck and Nonin, .88 between FibriCheck and AliveCor, and .897 between Nonin and AliveCor. A single way analysis of variance (ANOVA; P=.61 was executed to test the hypothesis that there were no significant differences between the HRs as measured by the 3 devices. In the second study, 20,298 (ms) R-R intervals (RRI)–peak-to-peak intervals (PPI) from 229 subjects were analyzed. This resulted in a positive correlation (rs=.993, root mean square deviation [RMSE]=23.04 ms, and normalized root mean square error [NRMSE]=0.012) between the PPI from FibriCheck and the RRI from the wearable ECG. There was no significant difference (P=.92) between these intervals. Conclusions Our findings suggest that the most suitable method for the validation of an HR app is a simultaneous measurement of the HR by the smartphone app and an ECG system, compared on the basis of beat-to-beat analysis. This approach could lead to more correct assessments of the accuracy of HR apps. PMID:28842392
[Phalloplethysmography findings in pedophilia and exhibitionism offenders].
Tichý, P
1996-08-21
Exhibitionist behaviour focused on children (usually girls) is one of the most frequent forms of sexual child abuse. Exposure in the presence of children signalizes possible pedophil inclinations of the offender. The present paper presents the results of PPG examinations of these offenders with special attention to assessment how often these men have an objective phallographic pedophil orientation. The results of PPG examinations in this group of sexual delinquents are also compared with the findings in a control group of men who report a heterosexual orientation and preference of objects of suitable age. Using an electrocapacitance phalloplythysmographic apparatus the authors examined 50 men (mean age 36.3 years, range 17-67 years) who committed exhibitionist activities in the presence of girls under 12 years. The PPG examination was made under standard conditions; all examined subjects were shown sets of coloured slides with adult and child objects of hetero and homosexual character. In the same way a control group was examined formed by 50 male volunteers of similar age and social background. The men in the control group responded more frequently and more merkedly by positive vasomotor reactions to adult heterosexual objects than subjects who committed pedophil exhibitionist offences. The latter reacted significantly more often to child objects of both sexes. In more than half the delinquent group (in 26 men) there was an undefined differentiation of age as regards objects of female sex and 6 (12%) men of this group had preference for heterosexual child objects, i.e. an obvious pedophil orientation. In men of the control group only in one case there was an indication of an ill defined differentiation of age, in all the others an unequivocal or clearly indicated preference of heterosexual objects was found. PPG examinations confirmed that only a minor part of subjects committing pedophil exhibitionist offences have a deviant orientation. It was revealed that the most frequent phallographic finding in this group of sexual delinquents is an ill defined differentiation of age in objects of female sex. The investigation confirmed the importance of phalloplethysmography in elucidating sexually motivated structures of offenders of pedophil sexual activities.
Presidential Green Chemistry Challenge: 2001 Designing Greener Chemicals Award
Presidential Green Chemistry Challenge 2001 award winner, PPG Industries, developed cationic electrodeposition coatings with yttrium that resist corrosion in automobiles. Yttrium is a safe replacement for lead in this use.
Continuous transport of Pacific-derived anthropogenic radionuclides towards the Indian Ocean
Pittauer, Daniela; Tims, Stephen G.; Froehlich, Michaela B.; Fifield, L. Keith; Wallner, Anton; McNeil, Steven D.; Fischer, Helmut W.
2017-01-01
Unusually high concentrations of americium and plutonium have been observed in a sediment core collected from the eastern Lombok Basin between Sumba and Sumbawa Islands in the Indonesian Archipelago. Gamma spectrometry and accelerator mass spectrometry data together with radiometric dating of the core provide a high-resolution record of ongoing deposition of anthropogenic radionuclides. A plutonium signature characteristic of the Pacific Proving Grounds (PPG) dominates in the first two decades after the start of the high yield atmospheric tests in 1950’s. Approximately 40–70% of plutonium at this site in the post 1970 period originates from the PPG. This sediment record of transuranic isotopes deposition over the last 55 years provides evidence for the continuous long-distance transport of particle-reactive radionuclides from the Pacific Ocean towards the Indian Ocean. PMID:28304374
A novel algorithm for reducing false arrhythmia alarms in intensive care units.
Srivastava, Chandan; Sharma, Sonal; Jalali, Ali
2016-08-01
Alarm fatigue in intensive care units (ICU) is one of the top healthcare issues in the US. False alarms in ICU will decrease the quality of care and staff response time over the alarms. Normally, false alarm will cause desensitization of the clinical staff which leads to warnings and misleading, if the triggered alarm is true. In this study, we have proposed a multi-model ensemble approach to reduce the false alarm rate in monitoring systems. We have used 750 patient records from PhysioNet database. At First arrhythmia based features from electrocardiogram (ECG), arterial blood pressure (ABP) and photoplethysmogram (PPG) features were extracted from the records. Next, the dataset has been separated into two subsets on the basis of available features information. The first dataset (DS1) is the combination of ECG physiological, ABP and PPG features. Their correlation coefficient and p-values criteria have been applied for relevant alarm-wise feature-set selection, and random forest classifier was used for model development and validation. The threshold based approach was used on second dataset (DS2) which is the combination of arrhythmia, ABP and PPG features. The developed ensemble model is able to achieve sensitivity 83.33-100 % (average 95.56 %) being true alarms and suppress false alarms rate 66.67-89% (average 77.25%). The predictability of classifier shows the advantage to deal with unbalanced set of information, therefore overall model performance has reached to 83.96% accuracy.
Jones, Kenneth R.; Herman, James P.; D'Alessio, David A.; Woods, Stephen C.; Seeley, Randy J.
2011-01-01
Central administration of glucagon-like peptide-1 (GLP-1) causes a dose-dependent reduction in food intake, but the role of endogenous CNS GLP-1 in the regulation of energy balance remains unclear. Here, we tested the hypothesis that CNS GLP-1 activity is required for normal energy balance by using two independent methods to achieve chronic CNS GLP-1 loss of function in rats. Specifically, lentiviral-mediated expression of RNA interference was used to knock down nucleus of the solitary tract (NTS) preproglucagon (PPG), and chronic intracerebroventricular (ICV) infusion of the GLP-1 receptor (GLP-1r) antagonist exendin (9-39) (Ex9) was used to block CNS GLP-1r. NTS PPG knockdown caused hyperphagia and exacerbated high-fat diet (HFD)-induced fat accumulation and glucose intolerance. Moreover, in control virus-treated rats fed the HFD, NTS PPG expression levels correlated positively with fat mass. Chronic ICV Ex9 also caused hyperphagia; however, increased fat accumulation and glucose intolerance occurred regardless of diet. Collectively, these data provide the strongest evidence to date that CNS GLP-1 plays a physiologic role in the long-term regulation of energy balance. Moreover, they suggest that this role is distinct from that of circulating GLP-1 as a short-term satiation signal. Therefore, it may be possible to tailor GLP-1-based therapies for the prevention and/or treatment of obesity. PMID:21389245
Multimodal Neurodiagnostic Tool for Exploration Missions
NASA Technical Reports Server (NTRS)
Lee, Yong Jin
2015-01-01
Linea Research Corporation has developed a neurodiagnostic tool that detects behavioral stress markers for astronauts on long-duration space missions. Lightweight and compact, the device is unobtrusive and requires minimal time and effort for the crew to use. The system provides a real-time functional imaging of cortical activity during normal activities. In Phase I of the project, Linea Research successfully monitored cortical activity using multiparameter sensor modules. Using electroencephalography (EEG) and functional near-infrared spectroscopy signals, the company obtained photoplethysmography and electrooculography signals to compute the heart rate and frequency of eye movement. The company also demonstrated the functionality of an algorithm that automatically classifies the varying degrees of cognitive loading based on physiological parameters. In Phase II, Linea Research developed the flight-capable neurodiagnostic device. Worn unobtrusively on the head, the device detects and classifies neurophysiological markers associated with decrements in behavior state and cognition. An automated algorithm identifies key decrements and provides meaningful and actionable feedback to the crew and ground-based medical staff.
NASA Astrophysics Data System (ADS)
Pavlov, Volodymyr S.; Bezsmernyi, Yurii O.; Zlepko, Sergey M.; Bezsmertna, Halyna V.
2017-08-01
The given paper analyzes principles of interaction and analysis of the reflected optical radiation from biotissue in the process of assessment of regional hemodynamics state in patients with local hypertensive- ischemic pain syndrome of amputation stumps of lower extremities, applying the method of photoplethysmography. The purpose is the evaluation of Laser photoplethysmography (LPPG) diagnostic value in examination of patients with chronic ischemia of lower extremities. Photonic device is developed to determine the level of the peripheral blood circulation, which determines the basic parameters of peripheral blood circulation and saturation level. Device consists of two sensors: infrared sensor, which contains the infrared laser radiation source and photodetector, and red sensor, which contains the red radiation source and photodetector. LPPG method allows to determined pulsatility of blood flow in different areas of the foot and lower leg, the degree of compensation and conservation perspectives limb. Surgical treatment of local hypertensive -ischemic pain syndrome of amputation stumps of lower extremities by means of semiclosed fasciotomy in combination with revasculating osteotrepanation enabled to improve considerably regional hemodynamics in the tissues of the stump and decrease pain and hypostatic disorders.
Kruger, Tillmann H C; Deiter, Frank; Zhang, Yuanyuan; Jung, Stefanie; Schippert, Cordula; Kahl, Kai G; Heinrichs, Markus; Schedlowski, Manfred; Hartmann, Uwe
2018-06-01
The neuropeptide oxytocin (OXT) has a variety of physiological functions in maternal behavior and attachment including sexual behavior. Based on animal research and our previous human studies, we set out to investigate intranasal administration of OXT and hypothesized that OXT should be able to modulate sexual function in women. In a double-blind, placebo-controlled, crossover laboratory setting, the acute effects of intranasal administered OXT (24 international units) on sexual drive, arousal, orgasm, and refractory aspects of sexual behavior were analyzed in 27 healthy females (mean age ± SD, 27.52 ± 8.04) together with physiological parameters using vaginal photoplethysmography. Oxytocin administration showed no effect on subjective sexual parameters (eg, postorgasmic tension; P = 0.051). Physiological parameters (vaginal photoplethysmography amplitude and vaginal blood volume) showed a response pattern towards sexual arousal but were not affected by OXT. Using a well-established laboratory paradigm, we did not find that intranasal OXT influences female sexual parameters. Also, sexual drive and other functions were not affected by OXT. These findings indicate that OXT is not able to significantly increase subjective and objective parameters of sexual function in a setting with high internal validity; however, this might be different in a more naturalistic setting.
Projects procedure guide : sampling frequencies for materials testing and inspection
DOT National Transportation Integrated Search
2002-02-01
The Bureau of Materials and Physical Research's Project Procedures Guide (PPG) is used as a resource for determining reasonable inspection procedures and sampling frequencies for materials used in highway construction. This Manual seeks to establish ...
Comparison of biodegradation of poly(ethylene glycol)s and poly(propylene glycol)s.
Zgoła-Grześkowiak, Agnieszka; Grześkowiak, Tomasz; Zembrzuska, Joanna; Łukaszewski, Zenon
2006-07-01
The biodegradation of poly(ethylene glycol)s (PEGs) and poly(propylene glycol)s (PPGs), both being major by-products of non-ionic surfactants biodegradation, was studied under the conditions of the River Water Die-Away Test. PEGs were isolated from a water matrix using solid-phase extraction with graphitized carbon black sorbent, then derivatized with phenyl isocyanate and determined by HPLC with UV detection. PPGs were isolated from a water matrix by liquid-liquid extraction with chloroform, then derivatized with naphthyl isocyanate and determined by HPLC with fluorescence detection. The primary biodegradation of both PEGs and PPGs reached approximately 99% during the test. The tests show different biodegradation pathways of PEG and PPG. During PEG biodegradation, their chains are shortened leading to the formation of ethylene glycol and diethylene glycol. During PPG biodegradation, no short-chained biodegradation products were found.
NASA Astrophysics Data System (ADS)
Sciascia, Luciana; Lombardo, Renato; Turco Liveri, Maria Liria
2006-10-01
The dynamic evolution of the oscillatory Belousov-Zhabotinsky reaction upon addition of increasing amount of the non-ionic polymer polypropylene glycol with molecular weight 425 g mol -1 (PPG-425) was investigated in a stirred-batch reactor by monitoring the Ce(IV) absorbance changes. The oscillatory parameters are significantly altered by the presence of the polymer. The findings obtained in the present work revealed that the PPG-425 is not only more effective, than other polymer previously [R. Lombardo, C. Sbriziolo, M.L. Turco Liveri, K. Pelle, M. Wittmann, Z. Noszticzius, in: J.A. Pojman, Q. Tran-Cong-Miyata (Eds.), Nonlinear Dynamics in Polymeric Systems, American Chemical Society, Washington, DC, 869 (2004) 292] studied, in perturbing the BZ systems but also more capable of producing key radical species, which in turn can be exploited for the preparation of new polymeric materials.
Localised photoplethysmography imaging for heart rate estimation of pre-term infants in the clinic
NASA Astrophysics Data System (ADS)
Chaichulee, Sitthichok; Villarroel, Mauricio; Jorge, João.; Arteta, Carlos; Green, Gabrielle; McCormick, Kenny; Zisserman, Andrew; Tarassenko, Lionel
2018-02-01
Non-contact vital-sign estimation allows the monitoring of physiological parameters (such as heart rate, respiratory rate, and peripheral oxygen saturation) without contact electrodes or sensors. Our recent work has demonstrated that a convolutional neural network (CNN) can be used to detect the presence of a patient and segment the patient's skin area for vital-sign estimation, thus enabling the automatic continuous monitoring of vital signs in a hospital environment. In a study approved by the local Research Ethical Committee, we made video recordings of pre-term infants nursed in a Neonatal Intensive Care Unit (NICU) at the John Radcliffe Hospital in Oxford, UK. We extended the CNN model to detect the head, torso and diaper of the infants. We extracted multiple photoplethysmographic imaging (PPGi) signals from each body part, analysed their signal quality, and compared them with the PPGi signal derived from the entire skin area. Our results demonstrated the benefits of estimating heart rate combined from multiple regions of interest using data fusion. In the test dataset, we achieved a mean absolute error of 2.4 beats per minute for 80% (31.1 hours) from a total recording time of 38.5 hours for which both reference heart rate and video data were valid.
Comparison of lung sound transducers using a bioacoustic transducer testing system.
Kraman, Steve S; Wodicka, George R; Pressler, Gary A; Pasterkamp, Hans
2006-08-01
Sensors used for lung sound research are generally designed by the investigators or adapted from devices used in related fields. Their relative characteristics have never been defined. We employed an artificial chest wall with a viscoelastic surface and a white noise signal generator as a stable source of sound to compare the frequency response and pulse waveform reproduction of a selection of devices used for lung sound research. We used spectral estimation techniques to determine frequency response and cross-correlation of pulses to determine pulse shape fidelity. The sensors evaluated were the Siemens EMT 25 C accelerometer (Siemens); PPG 201 accelerometer (PPG); Sony ECM-T150 electret condenser microphone with air coupler (air coupler; with cylindrical air chambers of 5-, 10-, and 15-mm diameter and conical air chamber of 10-mm diameter); Littman classic stethoscope head (Littman) connected to an electret condenser microphone; and the Andries Tek (Andries) electronic stethoscope. We found that the size and shape of the air coupler chamber to have no important effect on the detected sound. The Siemens, air coupler, and Littman performed similarly with relatively flat frequency responses from 200 to 1,200 Hz. The PPG had the broadest frequency response, with useful sensitivity extending to 4,000 Hz. The Andries' frequency response was the poorest above 1,000 Hz. Accuracy in reproducing pulses roughly corresponded with the high-frequency sensitivity of the sensors. We conclude that there are important differences among commonly used lung sound sensors that have to be defined to allow the comparison of data from different laboratories.
Pareek, Anil; Chandurkar, Nitin; Thomas, Nihal; Viswanathan, Vijay; Deshpande, Alaka; Gupta, O P; Shah, Asha; Kakrani, Arjun; Bhandari, Sudhir; Thulasidharan, N K; Saboo, Banshi; Devaramani, Shashidhar; Vijaykumar, N B; Sharma, Shrikant; Agrawal, Navneet; Mahesh, M; Kothari, Kunal
2014-07-01
To compare efficacy and safety of hydroxychloroquine with pioglitazone in type 2 diabetes mellitus (T2DM). This double-blind study randomized 267 uncontrolled type 2 diabetes patients (HbA1c ≥7.5% and ≤11.5%), post 3 months' treatment with glimepiride/gliclazide and metformin, to additionally receive hydroxychloroquine 400 mg/day (n = 135) or pioglitazone 15 mg/day (n = 132) for 24 weeks. Efficacy was assessed by changes in HbA1c, fasting (FBG) and post-prandial (PPG) blood glucose at Week 12 and Week 24. At Week 12 and Week 24, HbA1c, FBG and PPG significantly reduced from baseline in both groups. Mean reduction in glycemic parameters at Week 12 (HbA1c: -0.56% vs -0.72%, p = 0.394; FBG: -0.99 mmol/L vs -1.05 mmol/L, p = 0.878; PPG: -1.93 mmol/L vs -1.52 mmol/L, p = 0.423) and Week 24 (HbA1c: -0.87% vs -0.90%, p = 0.909; FBG: -0.79 mmol/L vs -1.02 mmol/L, p = 0.648; PPG: -1.77 mmol/L vs -1.36 mmol/L, p = 0.415) was not significantly different between the hydroxychloroquine and pioglitazone groups. Change in total cholesterol (TC) and LDL-C was significant in favor of hydroxychloroquine (TC: -0.37 mmol/L vs 0.03 mmol/L, p = 0.002; LDL-C: -0.23 mmol/L vs 0.09 mmol/L, p = 0.003). Triglycerides significantly reduced in both groups at Week 24. Mean HDL-C remained unchanged. Study treatments were well tolerated. With favorable effects on glycemic parameters and lipids, hydroxychloroquine may emerge as well tolerated therapeutic option for T2DM. The sample size for this study was small. However, based on the encouraging results of this proof-of-concept study, longer duration studies in larger population can be conducted to further confirm these findings. TRIAL REGISTRATION DETAILS: Clinical Trial Registry-India URL: http://ctri.nic.in, Registration Number: CTRI/2009/091/001036.
Barbosa Pereira, Carina; Czaplik, Michael; Blazek, Vladimir; Leonhardt, Steffen; Teichmann, Daniel
2018-05-13
Heart rate (HR) and respiratory rate (RR) are important parameters for patient assessment. However, current measurement techniques require attachment of sensors to the patient’s body, often leading to discomfort, stress and even pain. A new algorithm is presented for monitoring both HR and RR using thermal imaging. The cyclical ejection of blood flow from the heart to the head (through carotid arteries and thoracic aorta) leads to periodic movements of the head; these vertical movements are used to assess HR. Respiratory rate is estimated by using temperature fluctuations under the nose during the respiratory cycle. To test the viability and feasibility of this approach, a pilot study was conducted with 20 healthy subjects (aged 18⁻36 and 1 aged 50 years). The study consisted of two phases: phase A (frontal view acquisitions) and phase B (side view acquisitions). To validate the results, photoplethysmography and thoracic effort (piezoplethysmography) were simultaneously recorded. High agreement between infrared thermography and ground truth/gold standard was achieved. For HR, the root-mean-square errors (RMSE) for phases A and B were 3.53 ± 1.53 and 3.43 ± 1.61 beats per minute, respectively. For RR, the RMSE between thermal imaging and piezoplethysmography stayed around 0.71 ± 0.30 breaths per minute (phase A). This study demonstrates that infrared thermography may be a promising, clinically relevant alternative for the assessment of HR and RR.
1,1,2-Trichloroethane (TCE); Final Enforceable Consent Agreement and Testing Consent Order
EPA has issued an enforceable consent agreement (ECA) with The Dow Chemical Company; Vulcan Materials Company; Occidental Chemical Corp; Oxy Vinyls, LP; Georgia Gulf Corp; Westlake Chemical Corp; PPG, Borden Chemicals & Plastics, and Formosa Plastics.
1,2-Ethylene Dichloride; Final Enforceable Consent Agreement and Testing Consent Order
This document announces that EPA has signed an enforceable testing Consent Order with the Dow Chemical Co, Vulcan Materials Co, Occidental Chemical Corp, Oxy Vinyls, LP, Georgia Gulf Corp, Westlake Chemical Corp, PPG Industries, Inc., and Formosa Plastics.
Quantification of vascular function changes under different emotion states: A pilot study.
Xia, Yirong; Yang, Licai; Mao, Xueqin; Zheng, Dingchang; Liu, Chengyu
2017-01-01
Recent studies have indicated that physiological parameters change with different emotion states. This study aimed to quantify the changes of vascular function at different emotion and sub-emotion states. Twenty young subjects were studied with their finger photoplethysmographic (PPG) pulses recorded at three distinct emotion states: natural (1 minute), happiness and sadness (10 minutes for each). Within the period of happiness and sadness emotion states, two sub-emotion states (calmness and outburst) were identified with the synchronously recorded videos. Reflection index (RI) and stiffness index (SI), two widely used indices of vascular function, were derived from the PPG pulses to quantify their differences between three emotion states, as well as between two sub-emotion states. The results showed that, when compared with the natural emotion, RI and SI decreased in both happiness and sadness emotions. The decreases in RI were significant for both happiness and sadness emotions (both P< 0.01), but the decreases in SI was only significant for sadness emotion (P< 0.01). Moreover, for comparing happiness and sadness emotions, there was significant difference in RI (P< 0.01), but not in SI (P= 0.9). In addition, significant larger RI values were observed with the outburst sub-emotion in comparison with the calmness one for both happiness and sadness emotions (both P< 0.01) whereas significant larger SI values were observed with the outburst sub-emotion only in sadness emotion (P< 0.05). Moreover, gender factor hardly influence the RI and SI results for all three emotion measurements. This pilot study confirmed that vascular function changes with diffenrt emotion states could be quantified by the simple PPG measurement.
Reduction of motion artifact in pulse oximetry by smoothed pseudo Wigner-Ville distribution
Yan, Yong-sheng; Poon, Carmen CY; Zhang, Yuan-ting
2005-01-01
Background The pulse oximeter, a medical device capable of measuring blood oxygen saturation (SpO2), has been shown to be a valuable device for monitoring patients in critical conditions. In order to incorporate the technique into a wearable device which can be used in ambulatory settings, the influence of motion artifacts on the estimated SpO2 must be reduced. This study investigates the use of the smoothed psuedo Wigner-Ville distribution (SPWVD) for the reduction of motion artifacts affecting pulse oximetry. Methods The SPWVD approach is compared with two techniques currently used in this field, i.e. the weighted moving average (WMA) and the fast Fourier transform (FFT) approaches. SpO2 and pulse rate were estimated from a photoplethysmographic (PPG) signal recorded when subject is in a resting position as well as in the act of performing four types of motions: horizontal and vertical movements of the hand, and bending and pressing motions of the finger. For each condition, 24 sets of PPG signals collected from 6 subjects, each of 30 seconds, were studied with reference to the PPG signal recorded simultaneously from the subject's other hand, which was stationary at all times. Results and Discussion The SPWVD approach shows significant improvement (p < 0.05), as compared to traditional approaches, when subjects bend their finger or press their finger against the sensor. In addition, the SPWVD approach also reduces the mean absolute pulse rate error significantly (p < 0.05) from 16.4 bpm and 11.2 bpm for the WMA and FFT approaches, respectively, to 5.62 bpm. Conclusion The results suggested that the SPWVD approach could potentially be used to reduce motion artifact on wearable pulse oximeters. PMID:15737241
Wan, Yue-Meng; Li, Yu-Hua; Xu, Ying; Wu, Hua-Mei; Li, Ying-Chun; Wu, Xi-Nan; Yang, Jin-Hui
2018-01-16
Transjugular intrahepatic portosystemic shunt (TIPS) is an established method for portal hypertension. This study was to investigate the long-term safety, technical success, and patency of TIPS, and to determine the risk factors and clinical impacts of shunt dysfunction. A total of 154 consecutive patients undergoing embolotherapy of gastric coronary vein and/or short gastric vein and TIPS creation were prospectively studied. Follow-up data included technical success, patency and revision of TIPS, and overall survival of patients. During the study, the primary and secondary technical success rates were 98.7% and 100%, respectively. Sixty-three patients developed shunt dysfunction, 30 with shunt stenosis and 33 with shunt occlusion. The cumulative 60-month primary, primary assisted, and secondary patency rates were 19.6%, 43.0%, and 93.4%, respectively. The cumulative 60-month overall survival rates were similar between the TIPS dysfunction group and the TIPS non-dysfunction group (68.6% vs. 58.6%, P = .096). Baseline portal vein thrombosis (P < .001), use of bare stents (P = .018), and portal pressure gradient (PPG) (P = .020) were independent predictors for shunt dysfunction, hepatocellular carcinoma (P < .001), and ascites (P = .003) for overall survival. The accuracy of PPG for shunt dysfunction was statistically significant (P < .001), and a cutoff value of 8.5 had 77.8% sensitivity and 64.8% specificity. The long-term safety, technical success, and patency of TIPS were good; baseline portal vein thrombosis, use of bare stents, and PPG were significantly associated with shunt dysfunction; shunt dysfunction has little impact on patients' long-term survival because of high secondary patency rates. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Parker, Grace A; Sumners, Lindsay H; Zhao, Xiaoling; Honaker, Christa F; Siegel, Paul B; Cline, Mark A; Gilbert, Elizabeth R
2015-11-01
Chickens selected for low (LWS) and high (HWS) juvenile body weight (BW) for 55 generations differ in BW by 10-fold at selection age. High (HWR) and low (LWR) body weight-relaxed lines have been random-bred since the 46th generation. Our objective was to evaluate the developmental and nutritional regulation of pancreatic mRNA abundance of pancreatic and duodenal homeobox 1 (PDX1), preproinsulin (PPI), preproglucagon (PPG), and glucose transporter 2 (GLUT2). At day of hatch (DOH) and days 1, 3, 7, and 15 (D1, 3, 7 and 15, respectively), pancreas was collected and real time PCR was performed in Experiment 1. In Experiment 2, HWS and LWS were fed or delayed access to food for 72 h post-hatch, and pancreas collected at D15. There was an interaction of line and age for GLUT2 (P=0.001), PPI (P<0.0001), PPG (P=0.034), and PDX1 (P<0.0001). Expression was greater in chicks from LWR and LWS than HWR and HWS. There was an interaction of line and nutrition on PPG (P<0.0001) and GLUT2 (P=0.001) mRNA, where expression was similar among chicks that were fed but greater in LWS than HWS when chicks were delayed access to food. Thus, the first two weeks is important for maturation of pancreatic endocrine function. Long-term selection for BW is associated with differences in pancreas development, and delaying access to food at hatch may have persisting effects on glucose regulatory function. Copyright © 2015 Elsevier Inc. All rights reserved.
Beat-to-Beat Blood Pressure Monitor
NASA Technical Reports Server (NTRS)
Lee, Yong Jin
2012-01-01
This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.
Sardina, Paloma D; Martin, Jeffrey S; Avery, Joseph C; Braith, Randy W
2016-10-01
The purpose of the present study was to evaluate the potential clinical benefits of EECP on glycemic parameters [fasting plasma glucose (FPG), postprandial glucose (PPG120), glycosylated hemoglobin (HbA1c)] in patients with a clinical diagnosis of type II diabetes mellitus (T2DM). Thirty subjects (60.7 ± 1.9 years) with T2DM were randomly assigned (2:1 ratio) to receive either 35 1-h sessions of EECP (n = 20) or time-matched control of standard care (n = 10). FPG, PPG120, and HbA1c were evaluated before and at 48 h, 2 weeks, 3 and 6 months following EECP treatment or time-matched control. EECP significantly decreased FPG (-14.6 and -12.0 %), PPG120 (-14.6 and -13.5 %), and HbA1c (-11.5 and -19.6 %) 48 h following EECP and 2 weeks following EECP, respectively. HbA1c remained significantly reduced at 3 months following EECP (-14.3 %). The homeostasis model assessment of insulin resistance (-31.1 %) and whole-body composite insulin sensitivity index (+54.2 %) were significantly improved 48 h following EECP. Nitrite/nitrate (NO x ) was significantly increased 48 h following EECP (+48.4 %) and 2 weeks (+51.9 %) following EECP treatment. Our findings provide novel evidence that EECP improves glycemic control in patients with T2DM that persist for up to 3 months following treatment.
Zheng, Yu; Wang, Anping; Pan, Changyu; Lu, Juming; Dou, Jingtao; Lu, Zhaohui; Ba, Jianming; Wang, Baoan; Mu, Yiming
2015-01-01
The aim of the present study was to assess the relationship between night sleep duration and glycemic and triglyceride (TG) levels among people with different glycemic status. In all, 18,121 subjects aged ≥40 years were enrolled in this cross-sectional study, including 4318 with impaired glucose regulation (IGR), 4225 with diabetes, and 9578 with normal glucose regulation (NGR). The IGR + diabetes and NGR groups were divided into three subgroups according to self-reported night sleep duration as follows: (i) <6 h; (ii) 6-9 h; and (iii) >9 h. The associations of sleep duration with HbA1c, fasting plasma glucose (FPG), 2-h post-load plasma glucose (PPG), and TG levels were examined. Long night sleep duration (>9 h) was associated with higher HbA1c, FPG, PPG, and TG levels compared with sleep duration of 6-9 h (P < 0.01 for all) in the IGR + diabetes group, but not in the NGR group. This association was adjusted for potential confounders, including body mass index and depressive symptoms, and remained significant even after adjusting for snoring. A significant interaction between sleep duration and TG or snoring was observed for HbA1c levels, which attenuated the sleep-HbA1c association in the IGR + diabetes group. However, no significant association was observed between short night sleep duration and HbA1c levels. Long night sleep duration is associated with higher HbA1c, FPG, PPG, and TG levels in IGR and diabetes patients, independent of potential confounders. This may be important in clinical management of IGR and diabetes patients. © 2014 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.
Paris, F; Gaspari, L; Mbou, F; Philibert, P; Audran, F; Morel, Y; Biason-Lauber, A; Sultan, C
2016-03-01
Pubertal gynecomastia is a common condition observed in up to 65% of adolescent males. It is usually idiopathic and tends to regress within 1-2 years. In this descriptive cross-sectional study, we investigated 25 adolescent males with prominent (>B3) and/or persistent (>2 years) pubertal gynecomastia (P/PPG) to determine whether a hormonal/genetic defect might underline this condition. Endocrine investigation revealed the absence of hormonal disturbance for 18 boys (72%). Three patients presented Klinefelter syndrome and three a partial androgen insensitivity syndrome (PAIS) as a result of p.Ala646Asp and p.Ala45Gly mutations of the androgen receptor gene. The last patient showed a 17α-hydroxylase/17,20-lyase deficiency as a result of a compound heterozygous mutation of the CYP17A1 gene leading to p.Pro35Thr(P35T) and p.Arg239Stop(R239X) in the P450c17 protein. Enzymatic activity was analyzed: the mutant protein bearing the premature stop codon R239X showed a complete loss of 17α-hydroxylase and 17,20-lyase activity. The mutant P35T seemed to retain 15-20% of 17α-hydroxylase and about 8-10% of 17,20-lyase activity. This work demonstrates that P/PPG had an endocrine/genetic cause in 28% of our cases. PAIS may be expressed only by isolated gynecomastia as well as by 17α-hydroxylase/17,20-lyase deficiency. Isolated P/PPG is not always a 'physiological' condition and should thus be investigated through adequate endocrine and genetic investigations, even though larger studies are needed to better determine the real prevalence of genetic defects in such patients. © 2016 American Society of Andrology and European Academy of Andrology.
2012-01-01
Background During sexual development, filamentous ascomycetes form complex, three-dimensional fruiting bodies for the protection and dispersal of sexual spores. Fruiting bodies contain a number of cell types not found in vegetative mycelium, and these morphological differences are thought to be mediated by changes in gene expression. However, little is known about the spatial distribution of gene expression in fungal development. Here, we used laser microdissection (LM) and RNA-seq to determine gene expression patterns in young fruiting bodies (protoperithecia) and non-reproductive mycelia of the ascomycete Sordaria macrospora. Results Quantitative analysis showed major differences in the gene expression patterns between protoperithecia and total mycelium. Among the genes strongly up-regulated in protoperithecia were the pheromone precursor genes ppg1 and ppg2. The up-regulation was confirmed by fluorescence microscopy of egfp expression under the control of ppg1 regulatory sequences. RNA-seq analysis of protoperithecia from the sterile mutant pro1 showed that many genes that are differentially regulated in these structures are under the genetic control of transcription factor PRO1. Conclusions We have generated transcriptional profiles of young fungal sexual structures using a combination of LM and RNA-seq. This allowed a high spatial resolution and sensitivity, and yielded a detailed picture of gene expression during development. Our data revealed significant differences in gene expression between protoperithecia and non-reproductive mycelia, and showed that the transcription factor PRO1 is involved in the regulation of many genes expressed specifically in sexual structures. The LM/RNA-seq approach will also be relevant to other eukaryotic systems in which multicellular development is investigated. PMID:23016559
Umapathi, Reddicherla; Venkatesu, Pannuru
2017-01-01
Different biophysical techniques such as fluorescence spectroscopy, dynamic light scattering (DLS), viscosity (η) and Fourier transform infrared (FTIR) spectroscopy have been carried out to characterize the effect of imidazolium-based ionic liquids (ILs) on the thermo-responsive triblock copolymer, poly(ethylene glycol)-block-poly(propylene glycol)-block-poly-(ethylene glycol) (PEG-PPG-PEG). In addition, to demonstrate the distinct morphological changes of various self-assembled morphologies, we further employed field emission scanning electron microscope (FESEM). To investigate the effect of alkyl chain length of the cation, concentration of the ILs and the related Hofmeister series on the phase behaviour of PEG-PPG-PEG, we used a series of ILs possessing same Cl - anion and a set of cation [C n mim] + with increasing alkyl chain length of cation such as 1-ethyl-3-methylimidazolium chloride ([Emim][Cl]), 1-butyl-3-methylimidazolium chloride ([Bmim][Cl]), 1-hexyl-3-methylimidazolium chloride ([Hmim][Cl]) and 1-decyl-3-methylimidazolium chloride ([Dmim][Cl]). The critical micellization temperature (CMT) of the copolymer in the presence of well hydrated cations is directly correlated to their hydration. The overall specific ranking of ILs in decreasing the CMT of PEG-PPG-PEG in aqueous solution was [Emim][Cl]>[Bmim][Cl]>[Hmim][Cl]>[Dmim][Cl]. The trend of these ILs followed the well-known Hofmeister series of cations of ILs. The present study provides important information about the solution properties that can be helpful to tune the IL or temperature-sensitive copolymer CMT and micelle shapes which are crucial for understanding the drug delivery mechanisms. Copyright © 2016 Elsevier Inc. All rights reserved.
Respiratory rate extraction from pulse oximeter and electrocardiographic recordings.
Lee, Jinseok; Florian, John P; Chon, Ki H
2011-11-01
We present an algorithm of respiratory rate extraction using particle filter (PF), which is applicable to both photoplethysmogram (PPG) and electrocardiogram (ECG) signals. For the respiratory rate estimation, 1 min data are analyzed with combination of a PF method and an autoregressive model where among the resultant coefficients, the corresponding pole angle with the highest magnitude is searched since this reflects the closest approximation of the true breathing rate. The PPG data were collected from 15 subjects with the metronome breathing rate ranging from 24 to 36 breaths per minute in the supine and upright positions. The ECG data were collected from 11 subjects with spontaneous breathing ranging from 36 to 60 breaths per minute during treadmill exercises. Our method was able to accurately extract respiratory rates for both metronome and spontaneous breathing even during strenuous exercises. More importantly, despite slow increases in breathing rates concomitant with greater exercise vigor with time, our method was able to accurately track these progressive increases in respiratory rates. We quantified the accuracy of our method by using the mean, standard deviation and interquartile range of the error rates which all reflected high accuracy in estimating the true breathing rates. We are not aware of any other algorithms that are able to provide accurate respiratory rates directly from either ECG signals or PPG signals with spontaneous breathing during strenuous exercises. Our method is near real-time realizable because the computational time on 1 min data segment takes only 10 ms on a 2.66 GHz Intel Core2 microprocessor; the data are subsequently shifted every 10 s to obtain near-continuous breathing rates. This is an attractive feature since most other techniques require offline data analyses to estimate breathing rates.
De Souza, Aglecio Luiz; Batista, Gisele Almeida; Alegre, Sarah Monte
2017-01-01
We compare spectral analysis of photoplethysmography (PTG) with insulin resistance measured by the hyperinsulinemic euglycemic clamp (HEC) technique. A total of 100 nondiabetic subjects, 43 men and 57 women aged 20-63years, 30 lean, 42 overweight and 28 obese were enrolled in the study. These patients underwent an examination with HEC, and an examination with the PTG spectral analysis and calculation of the PTG Total Power (PTG-TP). Receiver-operating characteristic (ROC) curves were constructed to determine the specificity and sensitivity of PTG-TP in the assessment of insulin resistance. There is a moderate correlation between insulin sensitivity (M-value) and PTG-TP (r=- 0.64, p<0.0001). The ROC curves showed that the most relevant cutoff to the whole study group was a PTG-TP>406.2. This cut-off had a sensitivity=95.7%, specificity =84,4% and the area under the ROC curve (AUC)=0.929 for identifying insulin resistance. All AUC ROC curve analysis were significant (p<0.0001). The use of the PTG-TP marker measured from the PTG spectral analysis is a useful tool in screening and follow up of IR, especially in large-scale studies. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Transmission of cutaneous leishmaniasis by sand flies is enhanced by regurgitation of fPPG.
Rogers, Matthew E; Ilg, Thomas; Nikolaev, Andrei V; Ferguson, Michael A J; Bates, Paul A
2004-07-22
Sand flies are the exclusive vectors of the protozoan parasite Leishmania, but the mechanism of transmission by fly bite has not been determined nor incorporated into experimental models of infection. In sand flies with mature Leishmania infections the anterior midgut is blocked by a gel of parasite origin, the promastigote secretory gel. Here we analyse the inocula from Leishmania mexicana-infected Lutzomyia longipalpis sand flies. Analysis revealed the size of the infectious dose, the underlying mechanism of parasite delivery by regurgitation, and the novel contribution made to infection by filamentous proteophosphoglycan (fPPG), a component of promastigote secretory gel found to accompany the parasites during transmission. Collectively these results have important implications for understanding the relationship between the parasite and its vector, the pathology of cutaneous leishmaniasis in humans and also the development of effective vaccines and drugs. These findings emphasize that to fully understand transmission of vector-borne diseases the interaction between the parasite, its vector and the mammalian host must be considered together.
Supercritical CO2/Co-solvents Extraction of Porogen and Surfactant to Obtain
NASA Astrophysics Data System (ADS)
Lubguban, Jorge
2005-03-01
A method of pore generation by supercritical CO2 (SCCO2)/co-solvents extraction for the preparation of nanoporous organosilicate thin films for ultralow dielectric constant materials is investigated. A nanohybrid film was prepared from poly (propylene glycol) (PPG) and poly(methylsilsesquioxane) (PMSSQ) whereby the PPG porogen are entrapped within the crosslinked PMSSQ matrix. Another set of thin films was produced by liquid crystal templating whereby non-ionic (polyoxyethylene 10 stearyl ether) (Brij76) and ionic (cetyltrimethylammonium bromide) (CTAB) surfactant were used as sacrificial templates in a tetraethoxy silane (TEOS) and methyltrimethoxy silane (MTMS) based matrix. These two types of films were treated with SCCO2/co-solvents to remove porogen and surfactant templates. As a comparison, porous structures generated by thermal decomposition were also evaluated. It is found that SCCO2/co-solvents treatment produced closely comparable results with thermal decomposition. The results were evident from Fourier Transform Infrared (FT- IR) spectroscopy and optical constants data obtained from variable angle spectroscopic ellipsometry (VASE).
Safety Evaluation of Polyethylene Glycol (PEG) Compounds for Cosmetic Use
Shin, Chan Young; Kim, Kyu-Bong
2015-01-01
Polyethylene glycols (PEGs) are products of condensed ethylene oxide and water that can have various derivatives and functions. Since many PEG types are hydrophilic, they are favorably used as penetration enhancers, especially in topical dermatological preparations. PEGs, together with their typically nonionic derivatives, are broadly utilized in cosmetic products as surfactants, emulsifiers, cleansing agents, humectants, and skin conditioners. The compounds studied in this review include PEG/PPG-17/6 copolymer, PEG-20 glyceryl triisostearate, PEG-40 hydrogenated castor oil, and PEG-60 hydrogenated castor oil. Overall, much of the data available in this review are on PEGylated oils (PEG-40 and PEG-60 hydrogenated castor oils), which were recommended as safe for use in cosmetics up to 100% concentration. Currently, PEG-20 glyceryl triisostearate and PEGylated oils are considered safe for cosmetic use according to the results of relevant studies. Additionally, PEG/PPG-17/6 copolymer should be further studied to ensure its safety as a cosmetic ingredient. PMID:26191379
[A Case of Intestinal Obstruction Caused by a Bezoar after Pylous-Preserving Gastrectomy].
Yamazato, Yuzo; Kosuga, Toshiyuki; Ichikawa, Daisuke; Kubota, Takeshi; Okamoto, Kazuma; Konishi, Hirotaka; Shiozaki, Atsushi; Fujiwara, Hitoshi; Arita, Tomohiro; Morimura, Ryo; Murayama, Yasutoshi; Kuriu, Yoshiaki; Ikoma, Hisashi; Nakanishi, Masayoshi; Otsuji, Eigo
2017-11-01
A 65-year-old woman with a history of pylorus-preserving gastrectomy(PPG)for early gastric cancer visited our hospital because of vomiting. Gastrointestinal endoscopy revealed a large bezoar in the anastomotic site of the stomach. Because the bezoar was too large to be collected orally, the dissolution therapy with taking Coca-Cola®was continued. On the 3rd day after hospitalization, she felt acute abdominal pain with vomiting. Computed tomography revealed intestinal obstruction by a mass with air bubbles inside in the ileum. Emergency operation was performed under a diagnosis of intestinal obstruction due to the bezoar. The black brown bezoar sized 80×35×30mm was extracted through an ileotomy. The delayed gastric empty is considered to involve in the bezoar formation. Therefore, the appropriate education of diet and periodic endoscopic screening are necessary for patients with large amounts of gastric residues especially after PPG. In the dissolution therapy, physicians need to be careful of intestinal obstruction by a bezoar.
Bounded Kalman filter method for motion-robust, non-contact heart rate estimation
Prakash, Sakthi Kumar Arul; Tucker, Conrad S.
2018-01-01
The authors of this work present a real-time measurement of heart rate across different lighting conditions and motion categories. This is an advancement over existing remote Photo Plethysmography (rPPG) methods that require a static, controlled environment for heart rate detection, making them impractical for real-world scenarios wherein a patient may be in motion, or remotely connected to a healthcare provider through telehealth technologies. The algorithm aims to minimize motion artifacts such as blurring and noise due to head movements (uniform, random) by employing i) a blur identification and denoising algorithm for each frame and ii) a bounded Kalman filter technique for motion estimation and feature tracking. A case study is presented that demonstrates the feasibility of the algorithm in non-contact estimation of the pulse rate of subjects performing everyday head and body movements. The method in this paper outperforms state of the art rPPG methods in heart rate detection, as revealed by the benchmarked results. PMID:29552419
Clinical measurements analysis of multi-spectral photoplethysmograph biosensors
NASA Astrophysics Data System (ADS)
Asare, Lasma; Kviesis-Kipge, Edgars; Spigulis, Janis
2014-05-01
The developed portable multi-spectral photoplethysmograph (MS-PPG) optical biosensor device, intended for analysis of peripheral blood volume pulsations at different vascular depths, has been clinically verified. Multi-spectral monitoring was performed by means of a four - wavelengths (454 nm, 519 nm, 632 nm and 888 nm) light emitted diodes and photodiode with multi-channel signal output processing. Two such sensors can be operated in parallel and imposed on the patient's skin. The clinical measurements confirmed ability to detect PPG signals at four wavelengths simultaneously and to record temporal differences in the signal shapes (corresponding to different penetration depths) in normal and pathological skin. This study analyzed wavelengths relations between systole and diastole peak difference at various tissue depths in normal and pathological skin. The difference between parameters of healthy and pathological skin at various skin depths could be explain by oxy- and deoxyhemoglobin dominance at different wavelengths operated in sensor. The proposed methodology and potential clinical applications in dermatology for skin assessment are discussed.
ERIC Educational Resources Information Center
Rosenberg, Steve; McKeon, Loren Marie
1998-01-01
Describes the activities and benefits of Positive Peer Groups (PPG), a Cleveland-based diocese program involving 40 schools. Designed for students with behavioral or academic problems, it focuses on school service projects that teach students to develop and implement valuable social skills. Describes the positive social and academic effects PPG…
Zhang, Qingxue; Zhou, Dian; Zeng, Xuan
2017-02-06
Long-term continuous systolic blood pressure (SBP) and heart rate (HR) monitors are of tremendous value to medical (cardiovascular, circulatory and cerebrovascular management), wellness (emotional and stress tracking) and fitness (performance monitoring) applications, but face several major impediments, such as poor wearability, lack of widely accepted robust SBP models and insufficient proofing of the generalization ability of calibrated models. This paper proposes a wearable cuff-less electrocardiography (ECG) and photoplethysmogram (PPG)-based SBP and HR monitoring system and many efforts are made focusing on above challenges. Firstly, both ECG/PPG sensors are integrated into a single-arm band to provide a super wearability. A highly convenient but challenging single-lead configuration is proposed for weak single-arm-ECG acquisition, instead of placing the electrodes on the chest, or two wrists. Secondly, to identify heartbeats and estimate HR from the motion artifacts-sensitive weak arm-ECG, a machine learning-enabled framework is applied. Then ECG-PPG heartbeat pairs are determined for pulse transit time (PTT) measurement. Thirdly, a PTT&HR-SBP model is applied for SBP estimation, which is also compared with many PTT-SBP models to demonstrate the necessity to introduce HR information in model establishment. Fourthly, the fitted SBP models are further evaluated on the unseen data to illustrate the generalization ability. A customized hardware prototype was established and a dataset collected from ten volunteers was acquired to evaluate the proof-of-concept system. The semi-customized prototype successfully acquired from the left upper arm the PPG signal, and the weak ECG signal, the amplitude of which is only around 10% of that of the chest-ECG. The HR estimation has a mean absolute error (MAE) and a root mean square error (RMSE) of only 0.21 and 1.20 beats per min, respectively. Through the comparative analysis, the PTT&HR-SBP models significantly outperform the PTT-SBP models. The testing performance is 1.63 ± 4.44, 3.68, 4.71 mmHg in terms of mean error ± standard deviation, MAE and RMSE, respectively, indicating a good generalization ability on the unseen fresh data. The proposed proof-of-concept system is highly wearable, and its robustness is thoroughly evaluated on different modeling strategies and also the unseen data, which are expected to contribute to long-term pervasive hypertension, heart health and fitness management.
76 FR 63625 - National Heart, Lung, and Blood Institute; Notice of Closed Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-13
... Heart, Lung, and Blood Institute Special Emphasis Panel, Blood Pressure Regulations PPG. Date: November... Blood Institute; Notice of Closed Meetings Pursuant to section 10(d) of the Federal Advisory Committee... Blood Institute Special Emphasis Panel, NHLBI Conference Grant Review. Date: November 1-2, 2011. Time: 8...
This cost-review approach applies to all program and PPG awards made under 40 CFR Part 35, Subpart A, where the recipient has an established, on-going grant relationship with EPA and has adequate internal controls in its personnel.
Annual Report to Congress on Foreign Economic Collection and Industrial Espionage: 1998
1998-01-01
representatives of Owens - Corning Corporation, a primary PPG competitor. Both subjects were charged under Title 18 U.S.C., Section 1832 (Theft of Trade...information to an FBI undercover agent posing as a representative of Owens - Corning . Steven Davis stole and disclosed Gillette Company trade secrets to
A vigorous approach to customer service.
Pollock, E K
1993-01-01
PPG Industries, Inc. is the world's largest supplier of automotive original coatings. Its business-to-business customers require individualized service based on specific requirements. The company has solidified these relationships by establishing satellite supply facilities, applying the quality process to problem solving, and providing a variety of outlets for customer feedback.
ERIC Educational Resources Information Center
Ustati, Rusmanizah; Hassan, Sharifah Sariah Syed
2013-01-01
This study draws on the experience from a focus group interviews under the distance learning programme known as "Program Pensiswazahan Guru" (PPG) organized by the Malaysian Ministry of Education in collaboration with local universities and institutes of education. Its purpose is to uncover students' perception about the platform used by…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-06
... Institute of Diabetes and Digestive and Kidney Diseases Special Emphasis Panel, Liver PPG Application. Date... Diabetes and Digestive and Kidney Diseases; Notice of Closed Meetings Pursuant to section 10(d) of the...: National Institute of Diabetes and Digestive and Kidney Diseases Special Emphasis Panel, Nutrition Obesity...
An affordable cuff-less blood pressure estimation solution.
Jain, Monika; Kumar, Niranjan; Deb, Sujay
2016-08-01
This paper presents a cuff-less hypertension pre-screening device that non-invasively monitors the Blood Pressure (BP) and Heart Rate (HR) continuously. The proposed device simultaneously records two clinically significant and highly correlated biomedical signals, viz., Electrocardiogram (ECG) and Photoplethysmogram (PPG). The device provides a common data acquisition platform that can interface with PC/laptop, Smart phone/tablet and Raspberry-pi etc. The hardware stores and processes the recorded ECG and PPG in order to extract the real-time BP and HR using kernel regression approach. The BP and HR estimation error is measured in terms of normalized mean square error, Error Standard Deviation (ESD) and Mean Absolute Error (MAE), with respect to a clinically proven digital BP monitor (OMRON HBP1300). The computed error falls under the maximum standard allowable error mentioned by Association for the Advancement of Medical Instrumentation; MAE <; 5 mmHg and ESD <; 8mmHg. The results are validated using two-tailed dependent sample t-test also. The proposed device is a portable low-cost home and clinic bases solution for continuous health monitoring.
Jiang, Wen Jun; Wittek, Peter; Zhao, Li; Gao, Shi Chao
2014-01-01
Photoplethysmogram (PPG) signals acquired by smartphone cameras are weaker than those acquired by dedicated pulse oximeters. Furthermore, the signals have lower sampling rates, have notches in the waveform and are more severely affected by baseline drift, leading to specific morphological characteristics. This paper introduces a new feature, the inverted triangular area, to address these specific characteristics. The new feature enables real-time adaptive waveform detection using an algorithm of linear time complexity. It can also recognize notches in the waveform and it is inherently robust to baseline drift. An implementation of the algorithm on Android is available for free download. We collected data from 24 volunteers and compared our algorithm in peak detection with two competing algorithms designed for PPG signals, Incremental-Merge Segmentation (IMS) and Adaptive Thresholding (ADT). A sensitivity of 98.0% and a positive predictive value of 98.8% were obtained, which were 7.7% higher than the IMS algorithm in sensitivity, and 8.3% higher than the ADT algorithm in positive predictive value. The experimental results confirmed the applicability of the proposed method.
Electronic nicotine delivery systems: regulatory and safety challenges: Singapore perspective.
Cheah, Nuan Ping; Chong, Norman Wee Lin; Tan, Jing; Morsed, Faridatul Akmam; Yee, Shen Kuan
2014-03-01
Many electronic nicotine delivery systems (ENDS) are marketed as safer tobacco alternative products or effective cessation therapies. ENDS samples were evaluated for design features, including nicotine and glycols content. This could be useful in developing a legal framework to handle ENDS. Identification of the nicotine, glycerol and propylene glycol (PPG) contents was conducted using gas chromatography mass spectrometry with quantification performed using flame ionisation techniques. Varying nicotine amounts were found in ENDS cartridges which were labelled with the same concentration. Chemicals such as PPG and glycerol were found to be present in the nicotine-containing liquid of the cartridges. ENDS varied in their contents and packaging information. Limited information was available on the contents of nicotine and other chemicals present in a variety of ENDS sampled. Based on samples tested in this study, many contain misleading information on product ingredients. The results show poor consistency between actual nicotine content analysed on ENDS cartridges and the amount labelled. These findings raise safety and efficacy concerns for current and would-be recreational users or those trying to quit smoking.
Yigang, X U; Yijing, L I
2008-05-01
Lactobacillus casei ATCC 393 was selected as a bacterial carrier for the development of mucosal vaccine against porcine parvovirus (PPV) infection. The PPV major structural polypeptide VP2 was used as the model parvovirus antigen. Two inducible expression systems, namely pPG611.1 of the cell-surface expression system and pPG612.1 of the secretion expression system based on the xylose operon promoter were used to express the VP2 protein. The immunogenicity of recombinant strains producing VP2 protein in two cellular locations, cell-surface exposed and secreted, was compared to each other by immunizing mice through the intragastric administration. The two types of constructs were able to induce strong specific immune responses against VP2 via intragastric administration and maximum titres of IgA and IgG were attained on days 46 post oral immunization, while the highest antibody levels were obtained with the strain producing the VP2 protein in extracellular milieu. The induced antibodies demonstrated neutralizing effects on PPV infection.
Comtois, Gary; Mendelson, Yitzhak; Ramuka, Piyush
2007-01-01
Wearable physiological monitoring using a pulse oximeter would enable field medics to monitor multiple injuries simultaneously, thereby prioritizing medical intervention when resources are limited. However, a primary factor limiting the accuracy of pulse oximetry is poor signal-to-noise ratio since photoplethysmographic (PPG) signals, from which arterial oxygen saturation (SpO2) and heart rate (HR) measurements are derived, are compromised by movement artifacts. This study was undertaken to quantify SpO2 and HR errors induced by certain motion artifacts utilizing accelerometry-based adaptive noise cancellation (ANC). Since the fingers are generally more vulnerable to motion artifacts, measurements were performed using a custom forehead-mounted wearable pulse oximeter developed for real-time remote physiological monitoring and triage applications. This study revealed that processing motion-corrupted PPG signals by least mean squares (LMS) and recursive least squares (RLS) algorithms can be effective to reduce SpO2 and HR errors during jogging, but the degree of improvement depends on filter order. Although both algorithms produced similar improvements, implementing the adaptive LMS algorithm is advantageous since it requires significantly less operations.
Sjöstrand, Mikaela; Iqbal, Nayyar; Lu, Jane; Hirshberg, Boaz
2014-08-01
Saxagliptin reduced glycated hemoglobin (HbA1c), fasting plasma glucose (FPG), and postprandial glucose (PPG) in Asian patients with type 2 diabetes mellitus (T2DM). To understand the physiology of this effect, indices of α- and β-cell function were measured in a subpopulation of Chinese patients following a noodle mixed-meal tolerance test. Data from Chinese patients were pooled from two phase 3, 24-week studies of saxagliptin 5mg/d as monotherapy in drug-naive patients and as add-on to metformin in patients inadequately controlled with metformin alone. The end points for β- and α-cell function were change from baseline in C-peptide, insulin, and glucagon areas under the curve from 0 to 180 min (AUC0-180), insulinogenic index, and insulin sensitivity from Matsuda index after a mixed meal. Also glycemic variables, HbA1c, FPG, and PPG (AUC0-180), and homeostasis model assessment (HOMA) 2β were measured. At 24 weeks, greater improvements in adjusted mean change from baseline HbA1c (difference vs placebo [95% CI], -0.33% [-0.50%, -0.17%], [-4 (-5.5, -1.9) mmol/mol], P<0.0001), FPG (-0.41 [-0.78, -0.03] mmol/L, P=0.03), PPG AUC0-180 (-168 [-245, -91.8] mmol min/L, P<0.0001), C-peptide AUC0-180 (19.7 [5.2, 34.2] nmol min/L, P=0.008), insulinogenic index (0.06% [0.02%, 0.09%], P=0.002), and greater suppression of glucagon secretion (glucagon AUC0-180, -322 [-493.6, -150.7] pmol min/L, P=0.0003) were observed with saxagliptin versus placebo. In Chinese patients with T2DM, saxagliptin as monotherapy or as add-on to metformin improved glycemic control by modulating α- and β-cell function. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Zhang, Hongmei; Wang, Yuzhi; Zhou, Yigang; Chen, Jing; Wei, Xiaoxiao; Xu, Panli
2018-05-01
Deep eutectic solvent (DES) composed of polypropylene glycol 400 (PPG 400) and tetrabutylammonium bromide (TBAB) was combined with a series of new-type salts such as quaternary ammonium salts, amino acid and polyols to form Aqueous Biphasic Systems (ABSs). Phase-forming ability of the salts was investigated firstly. The results showed that polyols had a relatively weak power to produce phases within studied scopes. And the shorter of carbon chain length of salts, the easier to obtain phase-splitting. Then partitioning of three pigments in PPG 400/betaine-based ABSs was addressed to investigate the effect of pigments' hydrophobicity on extraction efficiency. It was found that an increase in hydrophobicity contributed to the migration of pigments in the DES-rich phase. On the other hand, with a decline in phase-forming ability of salts, the extraction efficiency of the whole systems started to go down gradually. Based on the results, selective separation experiment was conducted successfully in the PPG 400/betaine-based systems, including more than 93.00% Sudan Ⅲ in the top phase and about 80.00% sunset yellow FCF/amaranth in the bottom phase. Additionally, ABSs constructed by DES/betaine for partitioning amaranth were further utilized to explore the performances of influence factors and back extraction. It can be concluded that after the optimization above 98.00% amaranth was transferred into the top phase. And 67.98% amaranth can be transferred into the bottom phase in back-extraction experiment. At last, dynamic light scattering (DLS) and transmission electron microscope (TEM) were applied to probe into extraction mechanism. The results demonstrated that hydrophobicity played an important role in the separation process of pigments. Through combining with new-type DES, this work was devoted to introducing plentiful salts as novel compositions of ABSs and providing an eco-friendly extraction way for partitioning pigments, which boosted development of ABSs in the monitoring food safety field. Copyright © 2018 Elsevier B.V. All rights reserved.
Qi, Qi Ying Chun; Chen, Wen; Li, Xiao Ling; Wang, Yu Wei; Xie, Xiao Hua
2014-06-01
To investigate the effect of H₂S on lower limb ischemia-reperfusion (LIR) induced lung injury and explore the underlying mechanism. Wistar rats were randomly divided into control group, IR group, IR+ Sodium Hydrosulphide (NaHS) group and IR+ DL-propargylglycine (PPG) group. IR group as lung injury model induced by LIR were given 4 h reperfusion following 4 h ischemia of bilateral hindlimbs with rubber bands. NaHS (0.78 mg/kg) as exogenous H₂S donor and PPG (60 mg/kg) which can suppress endogenous H₂S production were administrated before LIR, respectively. The lungs were removed for histologic analysis, the determination of wet-to-dry weight ratios and the measurement of mRNA and protein levels of aquaporin-1 (AQP₁), aquaporin-5 (AQP₅) as indexes of water transport abnormality, and mRNA and protein levels of Toll-like receptor 4 (TLR₄), myeloid differentiation primary-response gene 88 (MyD88) and p-NF-κB as indexes of inflammation. LIR induced lung injury was accompanied with upregulation of TLR₄-Myd88-NF-κB pathway and downregulation of AQP1/AQP₅. NaHS pre-treatment reduced lung injury with increasing AQP₁/AQP₅ expression and inhibition of TLR₄-Myd88-NF-κB pathway, but PPG adjusted AQP₁/AQP₅ and TLR4 pathway to the opposite side and exacerbated lung injury. Endogenous H₂S, TLR₄-Myd88-NF-κB pathway and AQP₁/AQP₅ were involved in LIR induced lung injury. Increased H₂S would alleviate lung injury and the effect is at least partially depend on the adjustment of TLR₄-Myd88-NF-κB pathway and AQP₁/AQP₅ expression to reduce inflammatory reaction and lessen pulmonary edema. Copyright © 2014 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.
Effect of hydrogen sulfide on inflammatory cytokines in acute myocardial ischemia injury in rats
LIU, FANG; LIU, GUANG-JIE; LIU, NA; ZHANG, GANG; ZHANG, JIAN-XIN; LI, LAN-FANG
2015-01-01
Hydrogen sulfide (H2S) is believed to be involved in numerous physiological and pathophysiological processes, and now it is recognized as the third endogenous signaling gasotransmitter, following nitric oxide and carbon monoxide; however, the effects of H2S on inflammatory factors in acute myocardial ischemia injury in rats have not been clarified. In the present study, sodium hydrosulfide (NaHS) was used as the H2S donor. Thirty-six male Sprague Dawley rats were randomly divided into five groups: Sham, ischemia, ischemia + low-dose (0.78 mg/kg) NaHS, ischemia + medium-dose (1.56 mg/kg) NaHS, ischemia + high-dose (3.12 mg/kg) NaHS and ischemia + propargylglycine (PPG) (30 mg/kg). The rats in each group were sacrificed 6 h after the surgery for sample collection. Compared with the ischemia group, the cardiac damage in the rats in the ischemia + NaHS groups was significantly reduced, particularly in the high-dose group; in the ischemia + PPG group, the myocardial injury was aggravated compared with that in the ischemia group. Compared with the ischemia group, the levels of interleukin (IL)-1β, IL-6 and tumor necrosis factor-α (TNF-α) in the serum of rats in the ischemia + medium- and high-dose NaHS groups were significantly reduced, and the expression of intercellular adhesion molecule-1 (ICAM-1) mRNA and nuclear factor κ-light-chain-enhancer of activated B cells (NF-κB) protein in the myocardial tissues of rats was significantly reduced. In the ischemia + PPG group, the TNF-α, IL-1β and IL-6 levels in the serum were significantly increased, the expression of ICAM-1 mRNA was increased, although without a significant difference, and the expression of NF-κB was increased. The findings of the present study provide novel evidence for the dual effects of H2S on acute myocardial ischemia injury via the modulation of inflammatory factors. PMID:25667680
NASA Technical Reports Server (NTRS)
Rich, D. B.; Lautenberger, C. W.; Yuan, Z.; Fernandez-Pello, A. C.
2004-01-01
Experimental work on the effects of heat flux, oxygen concentration and glass fiber volume fraction on pyrolysate mass flux from samples of polypropylene/glass fiber composite (PP/G) is underway. The research is conducted as part of a larger project to develop a test methodology for flammability of materials, particularly composites, in the microgravity and variable oxygen concentration environment of spacecraft and space structures. Samples of PP/G sized at 30 x 30 x 10 mm are flush mounted in a flow tunnel, which provides a flow of oxidizer over the surface of the samples at a fixed value of 1 m/s and oxygen concentrations varying between 18 and 30%. Each sample is exposed to a constant external radiant heat flux at a given value, which varies between tests from 10 to 24 kW/sq m. Continuous sample mass loss and surface temperature measurements are recorded for each test. Some tests are conducted with an igniter and some are not. In the former case, the research goal is to quantify the critical mass flux at ignition for the various environmental and material conditions described above. The later case generates a wider range of mass flux rates than those seen prior to ignition, providing an opportunity to examine the protective effects of blowing on oxidative pyrolysis and heating of the surface. Graphs of surface temperature and sample mass loss vs. time for samples of 30% PPG at oxygen concentrations of 18 and 21% are presented in the figures below. These figures give a clear indication of the lower pyrolysis rate and extended time to ignition that accompany a lower oxygen concentration. Analysis of the mass flux rate at the time of ignition gives good repeatability but requires further work to provide a clear indication of mass flux trends accompanying changes in environmental and material properties.
NASA Technical Reports Server (NTRS)
Rich, D. B.; Lautenberger, C. W.; Yuan, Z.; Fernandez-Pello, A. C.
2004-01-01
Experimental work on the effects of heat flux, oxygen concentration and glass fiber volume fraction on pyrolysate mass flux from samples of polypropylene/glass fiber composite (PP/G) is underway. The research is conducted as part of a larger project to develop a test methodology for flammability of materials, particularly composites, in the microgravity and variable oxygen concentration environment of spacecraft and space structures. Samples of PP/G sized at 30x30x10 mm are flush mounted in a flow tunnel, which provides a flow of oxidizer over the surface of the samples at a fixed value of 1 m/s and oxygen concentrations varying between 18 and 30%. Each sample is exposed to a constant external radiant heat flux at a given value, which varies between tests from 10 to 24 kW/m2. Continuous sample mass loss and surface temperature measurements are recorded for each test. Some tests are conducted with an igniter and some are not. In the former case, the research goal is to quantify the critical mass flux at ignition for the various environmental and material conditions described above. The later case generates a wider range of mass flux rates than those seen prior to ignition, providing an opportunity to examine the protective effects of blowing on oxidative pyrolysis and heating of the surface. Graphs of surface temperature and sample mass loss vs. time for samples of 30% PPG at oxygen concentrations of 18 and 21% are presented in the figures below. These figures give a clear indication of the lower pyrolysis rate and extended time to ignition that accompany a lower oxygen concentration. Analysis of the mass flux rate at the time of ignition gives good repeatability but requires further work to provide a clear indication of mass flux trends accompanying changes in environmental and material properties.
Monte-Moreno, Enric
2011-10-01
This work presents a system for a simultaneous non-invasive estimate of the blood glucose level (BGL) and the systolic (SBP) and diastolic (DBP) blood pressure, using a photoplethysmograph (PPG) and machine learning techniques. The method is independent of the person whose values are being measured and does not need calibration over time or subjects. The architecture of the system consists of a photoplethysmograph sensor, an activity detection module, a signal processing module that extracts features from the PPG waveform, and a machine learning algorithm that estimates the SBP, DBP and BGL values. The idea that underlies the system is that there is functional relationship between the shape of the PPG waveform and the blood pressure and glucose levels. As described in this paper we tested this method on 410 individuals without performing any personalized calibration. The results were computed after cross validation. The machine learning techniques tested were: ridge linear regression, a multilayer perceptron neural network, support vector machines and random forests. The best results were obtained with the random forest technique. In the case of blood pressure, the resulting coefficients of determination for reference vs. prediction were R(SBP)(2)=0.91, R(DBP)(2)=0.89, and R(BGL)(2)=0.90. For the glucose estimation, distribution of the points on a Clarke error grid placed 87.7% of points in zone A, 10.3% in zone B, and 1.9% in zone D. Blood pressure values complied with the grade B protocol of the British Hypertension society. An effective system for estimate of blood glucose and blood pressure from a photoplethysmograph is presented. The main advantage of the system is that for clinical use it complies with the grade B protocol of the British Hypertension society for the blood pressure and only in 1.9% of the cases did not detect hypoglycemia or hyperglycemia. Copyright © 2011 Elsevier B.V. All rights reserved.
Herzner, Gudrun; Kaltenpoth, Martin; Poettinger, Theodor; Weiss, Katharina; Koedam, Dirk; Kroiss, Johannes; Strohm, Erhard
2013-01-01
Microbes pose severe threats to animals as competitors or pathogens and strongly affect the evolution of life history traits like parental care. Females of the European beewolf Philanthus triangulum, a solitary digger wasp, provision their offspring with paralyzed honeybees and embalm them with the secretion from large postpharyngeal glands (PPG) that contain mainly unsaturated hydrocarbons. This coating changes the physico-chemical properties of the prey surface, causes a reduction of water condensation and retards growth of mold fungi. Here we examined the closely related South American genus Trachypus, which shows a life-history similar to Philanthus. We investigated whether Trachypus spp. also possess PPGs and embalm larval provisions. Using histological methods and 3D reconstructions we show that Trachypus boharti and T. elongatus possess PPGs that are similar to P. triangulum but somewhat smaller. The ultrastructure of the gland epithelium suggests that the gland content is at least partly sequestered from the hemolymph. Chemical analyses using gas chromatography / mass spectrometry revealed that both the cuticle and PPGs of Trachypus contain mainly unsaturated long-chain hydrocarbons. The gland of T. boharti additionally contains long-chain ketones. The hydrocarbons from the PPG of T. elongatus occurred on prey bees excavated from nests in the field but not on conspecific control bees. While the embalming only slightly elevated the amount of hydrocarbons on prey bees, the proportion of unsaturated hydrocarbons, which is crucial for the antifungal effect, was significantly increased. The Trachypus species under study possess PPGs that are very similar to the PPG of P. triangulum with regard to morphology, ultrastructure and chemistry. Moreover, we provide clear evidence that T. elongatus females embalm their prey, presumably as a means of prey preservation. The observed differences among Trachypus and Philanthus in gland size and prey embalming may have evolved in response to divergent ecological conditions. PMID:24324830
2013-08-01
in central blood volume similar to hemorrhage in humans. Lower-body negative- pressure (LBNP) is a unique physiologic model that has been adopted to...relatively high tolerance (HT) to reduced blood volume, while 30% to 35% display low toler- ance (LT), with earlier onset of cardiovascular instability (i.e... pressure were recorded by infrared finger photoplethysmography (Finometer Blood Pressure Mon- itor, TNO-TPD Biomedical Instrumentation, Amsterdam
Noncontact measurement of emotional and physiological changes in heart rate from a webcam.
Madan, Christopher R; Harrison, Tyler; Mathewson, Kyle E
2018-04-01
Heart rate, measured in beats per minute, can be used as an index of an individual's physiological state. Each time the heart beats, blood is expelled and travels through the body. This blood flow can be detected in the face using a standard webcam that is able to pick up subtle changes in color that cannot be seen by the naked eye. Due to the light absorption spectrum of blood, we are able to detect differences in the amount of light absorbed by the blood traveling just below the skin (i.e., photoplethysmography). By modulating emotional and physiological stress-that is, viewing arousing images and sitting versus standing, respectively-to elicit changes in heart rate, we explored the feasibility of using a webcam as a psychophysiological measurement of autonomic activity. We found a high level of agreement between established physiological measures, electrocardiogram, and blood pulse oximetry, and heart rate estimates obtained from the webcam. We thus suggest webcams can be used as a noninvasive and readily available method for measuring psychophysiological changes, easily integrated into existing stimulus presentation software and hardware setups. © 2017 Society for Psychophysiological Research.
Bouchard, Katrina N; Chivers, Meredith L; Pukall, Caroline F
2017-01-01
Investigations of sexual concordance suggest that, on average, women exhibit a low, positive correlation between their subjective sexual arousal and genital response. However, this relationship appears to be stronger, on average, when genital response is measured via the external tissues of the vulva than within the vagina walls. Given the methodological variations, such as stimulus content and duration, in studies of vulvar and vaginal concordance, direct comparisons between individual studies are limited. In the current study, sexual concordance was examined using concurrent measures of vulvar blood flow (using laser Doppler imaging) and vaginal vasocongestion (using vaginal photoplethysmography) to investigate potential differences in vulvar and vaginal concordance. Twenty-five women viewed two erotic films that differed in sexual activity content (foreplay and intercourse) while their subjective sexual arousal and genital response was measured. In support of previous meta-analytic findings, results suggest that subjective sexual arousal is more strongly correlated with vulvar blood flow than with vaginal vasocongestion. Likewise, perceived genital response and actual vulvar blood flow are more strongly related than are vaginal vasocongestion and self-reported genital sensations. Practical implications for the study of women's sexual concordance as well as broader implications for the understanding of female sexuality are considered.
77 FR 75696 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-21
....'s Pine Street Yard in Orrville, OH, on the Wheeling and Lake Erie Railway. There are two end windows... eight windows each. No Type I or Type II FRA-certified glazing is currently installed in the car. However, all side windows are \\1/4\\-inch panes of Duplate ASI PPG Safety Glass. Some of these side windows...
Disgust versus Lust: Exploring the Interactions of Disgust and Fear with Sexual Arousal in Women.
Fleischman, Diana S; Hamilton, Lisa Dawn; Fessler, Daniel M T; Meston, Cindy M
2015-01-01
Sexual arousal is a motivational state that moves humans toward situations that inherently pose a risk of disease transmission. Disgust is an emotion that adaptively moves humans away from such situations. Incongruent is the fact that sexual activity is elementary to human fitness yet involves strong disgust elicitors. Using an experimental paradigm, we investigated how these two states interact. Women (final N=76) were assigned to one of four conditions: rate disgust stimuli then watch a pornographic clip; watch a pornographic clip then rate disgust stimuli; rate fear stimuli then watch a pornographic clip; or watch a pornographic clip then rate fear stimuli. Women's genital sexual arousal was measured with vaginal photoplethysmography and their disgust and fear reactions were measured via self-report. We did not find that baseline disgust propensity predicted sexual arousal in women who were exposed to neutral stimuli before erotic content. In the Erotic-before-Disgust condition we did not find that sexual arousal straightforwardly predicted decreased image disgust ratings. However, we did find some evidence that sexual arousal increased self-reported disgust in women with high trait disgust and sexual arousal decreased self-reported disgust in women with low trait disgust. Women who were exposed to disgusting images before erotic content showed significantly less sexual arousal than women in the control condition or women exposed to fear-inducing images before erotic content. In the Disgust-before-Erotic condition the degree of self-reported disgust was negatively correlated with genital sexual arousal. Hence, in the conflict between the ultimate goals of reproduction and disease avoidance, cues of the presence of pathogens significantly reduce the motivation to engage in mating behaviors that, by their nature, entail a risk of pathogen transmission.
Disgust versus Lust: Exploring the Interactions of Disgust and Fear with Sexual Arousal in Women
Fleischman, Diana S.; Hamilton, Lisa Dawn; Fessler, Daniel M. T.; Meston, Cindy M.
2015-01-01
Sexual arousal is a motivational state that moves humans toward situations that inherently pose a risk of disease transmission. Disgust is an emotion that adaptively moves humans away from such situations. Incongruent is the fact that sexual activity is elementary to human fitness yet involves strong disgust elicitors. Using an experimental paradigm, we investigated how these two states interact. Women (final N=76) were assigned to one of four conditions: rate disgust stimuli then watch a pornographic clip; watch a pornographic clip then rate disgust stimuli; rate fear stimuli then watch a pornographic clip; or watch a pornographic clip then rate fear stimuli. Women’s genital sexual arousal was measured with vaginal photoplethysmography and their disgust and fear reactions were measured via self-report. We did not find that baseline disgust propensity predicted sexual arousal in women who were exposed to neutral stimuli before erotic content. In the Erotic-before-Disgust condition we did not find that sexual arousal straightforwardly predicted decreased image disgust ratings. However, we did find some evidence that sexual arousal increased self-reported disgust in women with high trait disgust and sexual arousal decreased self-reported disgust in women with low trait disgust. Women who were exposed to disgusting images before erotic content showed significantly less sexual arousal than women in the control condition or women exposed to fear-inducing images before erotic content. In the Disgust-before-Erotic condition the degree of self-reported disgust was negatively correlated with genital sexual arousal. Hence, in the conflict between the ultimate goals of reproduction and disease avoidance, cues of the presence of pathogens significantly reduce the motivation to engage in mating behaviors that, by their nature, entail a risk of pathogen transmission. PMID:26106894
USDA-ARS?s Scientific Manuscript database
A preliminary study was conducted in a greenhouse (15 ± 1oC, with supplemental lights for 12 h/day) to determine the role of AMF on onion growth and for reducing the severity of onion stunting, using a commercial AMF inoculant, BioTerra Plus, that contains 104 propagules/g (ppg) of Glomus intraradic...
Aspergillus korhogoensis, a novel aflatoxin producing species from the Côte d’Ivoire
USDA-ARS?s Scientific Manuscript database
Based on examination of four isolates, this new species is described using a polyphasic approach. A concatenated alignment comprised of nine genes (ITS, benA, cmdA, mcm7, amdS, rpb1, preB, ppgA, preA) was subjected to phylogenetic analysis, and resulted in all four strains being inferred as a distin...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greener, J.M.; Trimble, G.E.; Singer, G.M.
This paper describes the Opon Gas Field development drilling case history in the Middle Magdalena Basin of north-central Colombia, South America. World class levels of drilling fluid and cementing densities in excess of 22.0 ppg were required to control the extreme pressures encountered. A continuous improvement process is detailed in regard to casing, drilling fluid, cement and related drilling mechanics programs in a severely pressured and environmentally sensitive operation.
Fabricate-On-Demand Vacuum Insulating Glazings
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCamy, James W.
PPG proposed to design a fabricate-on-demand manufacturing process to overcome the cost and supply chain issues preventing widespread adoption of vacuum insulated glazing (VIG) units. To do so, we focused on improving three areas of VIG manufacturing that drive high costs and limit the ability for smaller manufacturers to enter the market: edge sealing, pillar design/placement, and evacuating the VIG.
Li, DeXia; Guo, Gang; Deng, Xin; Fan, RangRang; Guo, QingFa; Fan, Min; Liang, Jian; Luo, Feng; Qian, ZhiYong
2013-01-01
Hot-melt extrusion (HME) plays an important role in preparing implants as local drug delivery systems in pharmaceutical fields. Here, a new PLA/PEG-PPG-PEG/Dexamethasone (PLA/F68/Dex) implant prepared by HME has been developed. Importantly, the implant was successfully achieved to control release of immunosuppressive drug to an implanted device. In particular, this implant has not been reported previously in pharmaceutical fields. FTIR and XRD were adopted to investigate the properties of the samples. The in vivo release study showed that the maximum value of Dex release from the implants was approximately 50% at 1 month. The in vivo degradation behavior was determined by UV spectrophotometer and scanning electron microscopy studies, and the weight loss rate of the implants were up to 25% at 1 month. Furthermore, complete blood count (CBC) test, serum chemistry and major organs were performed, and there is no significant lesion and side effects observed in these results. Therefore, the results elucidated that the new PLA/F68/Dex implant prepared by HME could deliver an immunosuppressive drug to control the inflammatory reaction at the implant site.
A meta-analysis of efficacy of Morus alba Linn. to improve blood glucose and lipid profile.
Phimarn, Wiraphol; Wichaiyo, Kittisak; Silpsavikul, Khuntawan; Sungthong, Bunleu; Saramunee, Kritsanee
2017-06-01
The previous studies have reported the Morus alba may improve blood glucose and lipid profile. The evidence from these studies is not consistent. This meta-analysis was to evaluate efficacy of products derived from M. alba on blood glucose and lipid levels. Literature was reviewed via international database (PubMed, PubMed Central, ScienceDirect, and SciSearch) and Thai databases. Thirteen RCTs with high quality, assessed by Jadad score, were included. M. alba expressed a significant reduction in postprandial glucose (PPG) at 30 min (MD -1.04, 95 % CI -1.36, -0.73), 60 min (MD -0.87, 95 % CI -1.27, -0.48) and 90 min (MD -0.55, 95 % CI -0.87, -0.22). The difference was not found in the levels of other glycaemic (FBS, HbA1C, or HOMA-IR) and lipidaemic (TC, TG, LDL, or HDL) markers. Serious adverse effects were found neither in the control nor in the group received M. alba. Products derived from M. alba can effectively contribute to the reduction in PPG levels, but large-scale RCTs would be informative.
Bhattacharya, Tinish; Gupta, Ankesh; Singh, Salam ThoiThoi; Roy, Sitikantha; Prasad, Anamika
2017-07-01
Cuff-less and non-invasive methods of Blood Pressure (BP) monitoring have faced a lot of challenges like stability, noise, motion artefact and requirement for calibration. These factors are the major reasons why such devices do not get approval from the medical community easily. One such method is calculating Blood Pressure indirectly from pulse transit time (PTT) obtained from electrocardiogram (ECG) and Photoplethysmogram (PPG). In this paper we have proposed two novel analog signal conditioning circuits for ECG and PPG that increase stability, remove motion artefacts, remove the sinusoidal wavering of the ECG baseline due to respiration and provide consistent digital pulses corresponding to blood pulses/heart-beat. We have combined these two systems to obtain the PTT and then correlated it with the Mean Arterial Pressure (MAP). The aim was to perform major part of the processing in analog domain to decrease processing load over microcontroller so as to reduce cost and make it simple and robust. We have found from our experiments that the proposed circuits can calculate the Heart Rate (HR) with a maximum error of ~3.0% and MAP with a maximum error of ~2.4% at rest and ~4.6% in motion.
Dias, Tania Cristina de Sá; Baby, André Rolim; Kaneko, Telma Mary; Velasco, Maria Valéria Robles
2008-06-01
Straightening is a chemical process by which excessively curly hair is straightened in an irreversible way. Generally, products are formulated as emulsions with high pH value (9.0-12.0), which, after applied on hair, cause considerable damage, making it dry and fragile. This research work evaluated the protective effect of lauryl PEG/PPG-18/18 methicone, cyclopentasiloxane (and) PEG-12 dimethicone cross-polymer, jojoba oil, and aqua (and) cystine bis-PG propyl silanetriol, as conditioning agents, on Afro-ethnic hair locks treated with thioglycolate-based straightening emulsions by protein loss, combability, and traction to rupture. Standard Afro-ethnic hair locks were prepared following a protocol for straightening emulsion application. Considering the assays performed, the addition of conditioning agents to the straightening emulsion with ammonium thioglycolate benefited the hair fiber, thus diminishing protein loss, protecting the hair thread, and improving resistance to breakage. Jojoba oil and lauryl PEG/PPG-18/18 methicone were the conditioning agents that presented the best results. Straightening emulsions with ammonium thioglycolate containing aqua (and) cystine bis-PG propyl silanetriol and cyclopentasiloxane (and) PEG-12 dimethicone cross-polymer were the ones that provided higher breakage resistance of the thread.
Park, Jong-Uk; Lee, Hyo-Ki; Lee, Junghun; Urtnasan, Erdenebayar; Kim, Hojoong; Lee, Kyoung-Joung
2015-09-01
This study proposes a method of automatically classifying sleep apnea/hypopnea events based on sleep states and the severity of sleep-disordered breathing (SDB) using photoplethysmogram (PPG) and oxygen saturation (SpO2) signals acquired from a pulse oximeter. The PPG was used to classify sleep state, while the severity of SDB was estimated by detecting events of SpO2 oxygen desaturation. Furthermore, we classified sleep apnea/hypopnea events by applying different categorisations according to the severity of SDB based on a support vector machine. The classification results showed sensitivity performances and positivity predictive values of 74.2% and 87.5% for apnea, 87.5% and 63.4% for hypopnea, and 92.4% and 92.8% for apnea + hypopnea, respectively. These results represent better or comparable outcomes compared to those of previous studies. In addition, our classification method reliably detected sleep apnea/hypopnea events in all patient groups without bias in particular patient groups when our algorithm was applied to a variety of patient groups. Therefore, this method has the potential to diagnose SDB more reliably and conveniently using a pulse oximeter.
Consistency of Continuous Ambulatory Interstitial Glucose Monitoring Sensors.
Wu, Pei T; Segovia, David E; Lee, Cathy C; Nguyen, Kim-Lien
2018-05-16
The abdominal region is the most common location for continuous glucose monitor (CGM) sensor insertion. However, a paucity of post-marketing data is available to demonstrate intra-individual consistency of CGM readings at different abdominal insertion sites. Healthy adults (fasting glucose (FG) < 5.5 mmol/L; BMI < 30 kg/m²) were recruited and a CGM sensor was placed on each side of the abdomen. Postprandial and continuous 48-h interstitial glucose levels were analyzed. There was no significant difference in the 3-h postprandial glucose (PPG) level derived from the left versus right CGM, which remained non-significant after adjusting for waist circumference or FG. Among the glucose levels recorded over 48-h, values on the left site were greater in 3.6% of the data points ( p < 0.05). After adjusting for waist circumference, only 0.5% of the glucose values remained significantly greater on the left ( p < 0.05). When adjusted for FG, similar results were observed. For both PPG and 48-h readings, the mean absolute relative difference was not significant between the two abdominal sites. CGM-derived glucose measures were highly consistent between the left and right abdomen during both the postprandial and post-absorptive periods.
NASA Astrophysics Data System (ADS)
Kim, Min Chan
2014-11-01
To simulate a CO2 sequestration process, some researchers employed a water/propylene glycol (PPG) system which shows a non-monotonic density profile. Motivated by this fact, the stability of the diffusion layer of two miscible fluids saturated in a porous medium is analyzed. For a non-monotonic density profile system, linear stability equations are derived in a global domain, and then transformed into a system of ordinary differential equations in an infinite domain. Initial growth rate analysis is conducted without the quasi-steady state approximation (QSSA) and shows that initially the system is unconditionally stable for the least stable disturbance. For the time evolving case, the ordinary differential equations are solved applying the eigen-analysis and numerical shooting scheme with and without the QSSA. To support these theoretical results, direct numerical simulations are conducted using the Fourier spectral method. The results of theoretical linear stability analyses and numerical simulations validate one another. The present linear and nonlinear analyses show that the water/PPG system is more unstable than the CO2/brine one, and the flow characteristics of these two systems are quite different from each other.
Clinical Validation of Heart Rate Apps: Mixed-Methods Evaluation Study.
Vandenberk, Thijs; Stans, Jelle; Mortelmans, Christophe; Van Haelst, Ruth; Van Schelvergem, Gertjan; Pelckmans, Caroline; Smeets, Christophe Jp; Lanssens, Dorien; De Cannière, Hélène; Storms, Valerie; Thijs, Inge M; Vaes, Bert; Vandervoort, Pieter M
2017-08-25
Photoplethysmography (PPG) is a proven way to measure heart rate (HR). This technology is already available in smartphones, which allows measuring HR only by using the smartphone. Given the widespread availability of smartphones, this creates a scalable way to enable mobile HR monitoring. An essential precondition is that these technologies are as reliable and accurate as the current clinical (gold) standards. At this moment, there is no consensus on a gold standard method for the validation of HR apps. This results in different validation processes that do not always reflect the veracious outcome of comparison. The aim of this paper was to investigate and describe the necessary elements in validating and comparing HR apps versus standard technology. The FibriCheck (Qompium) app was used in two separate prospective nonrandomized studies. In the first study, the HR of the FibriCheck app was consecutively compared with 2 different Food and Drug Administration (FDA)-cleared HR devices: the Nonin oximeter and the AliveCor Mobile ECG. In the second study, a next step in validation was performed by comparing the beat-to-beat intervals of the FibriCheck app to a synchronized ECG recording. In the first study, the HR (BPM, beats per minute) of 88 random subjects consecutively measured with the 3 devices showed a correlation coefficient of .834 between FibriCheck and Nonin, .88 between FibriCheck and AliveCor, and .897 between Nonin and AliveCor. A single way analysis of variance (ANOVA; P=.61 was executed to test the hypothesis that there were no significant differences between the HRs as measured by the 3 devices. In the second study, 20,298 (ms) R-R intervals (RRI)-peak-to-peak intervals (PPI) from 229 subjects were analyzed. This resulted in a positive correlation (rs=.993, root mean square deviation [RMSE]=23.04 ms, and normalized root mean square error [NRMSE]=0.012) between the PPI from FibriCheck and the RRI from the wearable ECG. There was no significant difference (P=.92) between these intervals. Our findings suggest that the most suitable method for the validation of an HR app is a simultaneous measurement of the HR by the smartphone app and an ECG system, compared on the basis of beat-to-beat analysis. This approach could lead to more correct assessments of the accuracy of HR apps. ©Thijs Vandenberk, Jelle Stans, Gertjan Van Schelvergem, Caroline Pelckmans, Christophe JP Smeets, Dorien Lanssens, Hélène De Cannière, Valerie Storms, Inge M Thijs, Pieter M Vandervoort. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 25.08.2017.
1994-04-01
focus of this thesis. The Supreme Court articulated an analytical framework for Title VII disparate treatment cases principally in McDonald Douglas Corp...a footnote. Roush v. KFC National Management Co., 10 F.3d 392, 396 n.5 (6th Cir. 1993). 276. Bodenheimer v. PPG Industries, Inc., 5 F.3d 955, 957
Stress Wave and Damage Propagation in Transparent Laminates at Elevated Temperatures
2010-03-01
materials like Starphire (a registered trademark of PPG Industries, Pittsburgh, PA) soda - lime glass , borosilicate glass , fused silica , and the...in transparent armor materials like Starphire soda - lime glass , borosilicate glass , fused silica , and the transparent ceramic AlON.1 Since...transparent ceramic AlON. Since transparent armor consists of glass laminates with polymer interlayer and backing, the influence of interlayer type and
Optimal defense theory explains deviations from latitudinal herbivory defense hypothesis.
Kooyers, Nicholas J; Blackman, Benjamin K; Holeski, Liza M
2017-04-01
The latitudinal herbivory defense hypothesis (LHDH) postulates that the prevalence of species interactions, including herbivory, is greater at lower latitudes, leading to selection for increased levels of plant defense. While latitudinal defense clines may be caused by spatial variation in herbivore pressure, optimal defense theory predicts that clines could also be caused by ecogeographic variation in the cost of defense. For instance, allocation of resources to defense may not increase plant fitness when growing seasons are short and plants must reproduce quickly. Here we use a common garden experiment to survey genetic variation for constitutive and induced phenylpropanoid glycoside (PPG) concentrations across 35 Mimulus guttatus populations over a ~13° latitudinal transect. Our sampling regime is unique among studies of the LHDH in that it allows us to disentangle the effects of growing season length from those of latitude, temperature, and elevation. For five of the seven PPGs surveyed, we find associations between latitude and plant defense that are robust to population structure. However, contrary to the LHDH, only two PPGs were found at higher levels in low latitude populations, and total PPG concentrations were higher at higher latitudes. PPG levels are strongly correlated with growing season length, with higher levels of PPGs in plants from areas with longer growing seasons. Further, flowering time is positively correlated with the concentration of nearly all PPGs, suggesting that there may be a strong trade-off between development time and defense production. Our results reveal that ecogeographic patterns in plant defense may reflect variation in the cost of producing defense compounds in addition to variation in herbivore pressure. Thus, the biogeographic pattern predicted by the LHDH may not be accurate because the underlying factors driving variation in defense, in this case, growing season length, are not always associated with latitude in the same manner. Given these results, we conclude that LHDH cannot be interpreted without considering life history, and we recommend that future work on the LHDH move beyond solely testing the core LHDH prediction and place greater emphasis on isolating agents of selection that generate spatial variation in defense and herbivore pressure. © 2017 by the Ecological Society of America.
Yang, Liyu; Amad, Ma'an; Winnik, Witold M; Schoen, Alan E; Schweingruber, Hans; Mylchreest, Iain; Rudewicz, Patrick J
2002-01-01
Triple quadrupole mass spectrometers, when operated in multiple reaction monitoring (MRM) mode, offer a unique combination of sensitivity, specificity, and dynamic range. Consequently, the triple quadrupole is the workhorse for high-throughput quantitation within the pharmaceutical industry. However, in the past, the unit mass resolution of quadrupole instruments has been a limitation when interference from matrix or metabolites cannot be eliminated. With recent advances in instrument design, triple quadrupole instruments now afford mass resolution of less than 0.1 Dalton (Da) full width at half maximum (FWHM). This paper describes the evaluation of an enhanced resolution triple quadrupole mass spectrometer for high-throughput bioanalysis with emphasis on comparison of selectivity, sensitivity, dynamic range, precision, accuracy, and stability under both unit mass (1 Da FWHM) and enhanced (
Zhang, Jinping; Wang, Na; Xing, Xiaoyan; Yang, Zhaojun; Wang, Xin; Yang, Wenying
2016-01-01
To conduct a subanalysis of the randomized MARCH (Metformin and AcaRbose in Chinese as the initial Hypoglycemic treatment) trial to investigate whether specific characteristics are associated with the efficacy of either acarbose or metformin as initial therapy. A total of 657 type 2 diabetes patients who were randomly assigned to 48 weeks of therapy with either acarbose or metformin in the MARCH trial were divided into two groups based upon their hemoglobin A1c (HbA1c) levels at the end of follow-up: HbA1c <7% (<53 mmol/mol) and ≥7% (≥53 mmol/mol). Univariate, multivariate, and stepwise linear regression analyses were applied to identify the factors associated with treatment efficacy. Because this was a subanalysis, no measurement was performed. Univariate analysis showed that the efficacy of acarbose and metformin was influenced by HbA1c, fasting blood glucose (FBG), and 2 hour postprandial venous blood glucose (2hPPG) levels, as well as by changes in body mass index (BMI) (p ≤ 0.006). Multivariate analysis and stepwise linear regression analyses indicated that lower baseline 2hPPG values and greater changes in BMI were factors that positively influenced efficacy in both treatment groups (p ≤ 0.05). Stepwise regression model analysis also revealed that a lower baseline homeostasis model assessment-estimated insulin resistance (HOMA-IR) and higher serum insulin area under the curve (AUC) were factors positively influencing HbA1c normalization in all patients (p ≤ 0.032). Newly diagnosed type 2 diabetes patients with lower baseline 2hPPG and HOMA-IR values are more likely to achieve glucose control with acarbose or metformin treatment. Furthermore, the change in BMI after acarbose or metformin treatment is also a factor influencing HbA1c normalization. A prospective study with a larger sample size is necessary to confirm our results as well as measure β cell function and examine the influence of the patients' dietary habits.
A novel multivariate STeady-state index during general ANesthesia (STAN).
Castro, Ana; de Almeida, Fernando Gomes; Amorim, Pedro; Nunes, Catarina S
2017-08-01
The assessment of the adequacy of general anesthesia for surgery, namely the nociception/anti-nociception balance, has received wide attention from the scientific community. Monitoring systems based on the frontal EEG/EMG, or autonomic state reactions (e.g. heart rate and blood pressure) have been developed aiming to objectively assess this balance. In this study a new multivariate indicator of patients' steady-state during anesthesia (STAN) is proposed, based on wavelet analysis of signals linked to noxious activation. A clinical protocol was designed to analyze precise noxious stimuli (laryngoscopy/intubation, tetanic, and incision), under three different analgesic doses; patients were randomized to receive either remifentanil 2.0, 3.0 or 4.0 ng/ml. ECG, PPG, BP, BIS, EMG and [Formula: see text] were continuously recorded. ECG, PPG and BP were processed to extract beat-to-beat information, and [Formula: see text] curve used to estimate the respiration rate. A combined steady-state index based on wavelet analysis of these variables, was applied and compared between the three study groups and stimuli (Wilcoxon signed ranks, Kruskal-Wallis and Mann-Whitney tests). Following institutional approval and signing the informed consent thirty four patients were enrolled in this study (3 excluded due to signal loss during data collection). The BIS index of the EEG, frontal EMG, heart rate, BP, and PPG wave amplitude changed in response to different noxious stimuli. Laryngoscopy/intubation was the stimulus with the more pronounced response [Formula: see text]. These variables were used in the construction of the combined index STAN; STAN responded adequately to noxious stimuli, with a more pronounced response to laryngoscopy/intubation (18.5-43.1 %, [Formula: see text]), and the attenuation provided by the analgesic, detecting steady-state periods in the different physiological signals analyzed (approximately 50 % of the total study time). A new multivariate approach for the assessment of the patient steady-state during general anesthesia was developed. The proposed wavelet based multivariate index responds adequately to different noxious stimuli, and attenuation provided by the analgesic in a dose-dependent manner for each stimulus analyzed in this study.
Detection of low-volume blood loss: compensatory reserve versus traditional vital signs.
Stewart, Camille L; Mulligan, Jane; Grudic, Greg Z; Convertino, Victor A; Moulton, Steven L
2014-12-01
Humans are able to compensate for low-volume blood loss with minimal change in traditional vital signs. We hypothesized that a novel algorithm, which analyzes photoplethysmogram (PPG) wave forms to continuously estimate compensatory reserve would provide greater sensitivity and specificity to detect low-volume blood loss compared with traditional vital signs. The compensatory reserve index (CRI) is a measure of the reserve remaining to compensate for reduced central blood volume, where a CRI of 1 represents supine normovolemia and 0 represents the circulating blood volume at which hemodynamic decompensation occurs; values between 1 and 0 indicate the proportion of reserve remaining. Subjects underwent voluntary donation of 1 U (approximately 450 mL) of blood. Demographic and continuous noninvasive vital sign wave form data were collected, including PPG, heart rate, systolic blood pressure, cardiac output, and stroke volume. PPG wave forms were later processed by the algorithm to estimate CRI values. Data were collected from 244 healthy subjects (79 males and 165 females), with a mean (SD) age of 40.1 (14.2) years and mean (SD) body mass index of 25.6 (4.7). After blood donation, CRI significantly decreased in 92% (α = 0.05; 95% confidence interval [CI], 88-95%) of the subjects. With the use of a threshold decrease in CRI of 0.05 or greater for the detection of 1 U of blood loss, the receiver operating characteristic area under the curve was 0.90, with a sensitivity of 0.84 and specificity of 0.86. In comparison, systolic blood pressure (52%; 95% CI, 45-59%), heart rate (65%; 95% CI, 58-72%), cardiac output (47%; 95% CI, 40-54%), and stroke volume (74%; 95% CI, 67-80%) changed in fewer subjects, had significantly lower receiver operating characteristic area under the curve values, and significantly lower specificities for detecting the same volume of blood loss. Consistent with our hypothesis, CRI detected low-volume blood loss with significantly greater specificity than other traditional physiologic measures. These findings warrant further evaluation of the CRI algorithm in actual trauma settings. Diagnostic study, level II.
Pulverman, Carey S; Hixon, J Gregory; Meston, Cindy M
2015-10-01
Based on analytic techniques that collapse data into a single average value, it has been reported that women lack category specificity and show genital sexual arousal to a large range of sexual stimuli including those that both match and do not match their self-reported sexual interests. These findings may be a methodological artifact of the way in which data are analyzed. This study examined whether using an analytic technique that models data over time would yield different results. Across two studies, heterosexual (N = 19) and lesbian (N = 14) women viewed erotic films featuring heterosexual, lesbian, and gay male couples, respectively, as their physiological sexual arousal was assessed with vaginal photoplethysmography. Data analysis with traditional methods comparing average genital arousal between films failed to detect specificity of genital arousal for either group. When data were analyzed with smoothing regression splines and a within-subjects approach, both heterosexual and lesbian women demonstrated different patterns of genital sexual arousal to the different types of erotic films, suggesting that sophisticated statistical techniques may be necessary to more fully understand women's genital sexual arousal response. Heterosexual women showed category-specific genital sexual arousal. Lesbian women showed higher arousal to the heterosexual film than the other films. However, within subjects, lesbian women showed significantly different arousal responses suggesting that lesbian women's genital arousal discriminates between different categories of stimuli at the individual level. Implications for the future use of vaginal photoplethysmography as a diagnostic tool of sexual preferences in clinical and forensic settings are discussed. © 2015 Society for Psychophysiological Research.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akl, Tony; Wilson, Mark A.; Ericson, Milton Nance
2014-01-01
Photoplethysmography is a widely used technique in monitoring perfusion and blood oxygen saturation by using the amplitude of the pulsatile signal on one or multiple wavelengths. However, the pulsatile signal carries in its waveform a substantial amount of information about the mechanical properties of the tissue and vasculature under investigation that is still yet to be utilized to its full potential. In this work, we present the feasibility of pulse wave analysis for the application of monitoring hepatic implants and diagnosing graft complications. In particular, we show the possibility of computing the slope of the pulse during the diastole phasemore » to assess the location of vascular complications when they take place. This hypothesis was tested in a series of in vitro experiments using a PDMS based phantom mimicking the optical and mechanical properties of the portal vein. The emptying time of the vessel increased from 305 ms to 515 ms when an occlusion was induced downstream from the phantom. However, in the case of upstream occlusions, the emptying time remained constant. In both cases, a decrease in the amplitude of the pulse was recorded indicating the drop in flow levels. In addition, we show that quantifying the emptying time of the vasculature under investigation can be used to assess its compliance. The emptying time decreased from 305 ms for phantoms with compliance of 15 KPa to 195 ms for phantoms with compliance of 100 KPa. These compliance levels mimic those seen for normal and fibrotic hepatic tissue respectively.« less
Dieffenderfer, James; Goodell, Henry; Mills, Steven; McKnight, Michael; Yao, Shanshan; Lin, Feiyan; Beppler, Eric; Bent, Brinnae; Lee, Bongmook; Misra, Veena; Zhu, Yong; Oralkan, Omer; Strohmaier, Jason; Muth, John; Peden, David; Bozkurt, Alper
2016-01-01
We present our efforts towards enabling a wearable sensor system that allows for the correlation of individual environmental exposures to physiologic and subsequent adverse health responses. This system will permit a better understanding of the impact of increased ozone levels and other pollutants on chronic asthma conditions. We discuss the inefficiency of existing commercial off-the-shelf components to achieve continuous monitoring and our system-level and nano-enabled efforts towards improving the wearability and power consumption. Our system consists of a wristband, a chest patch, and a handheld spirometer. We describe our preliminary efforts to achieve a sub-milliwatt system ultimately powered by the energy harvested from thermal radiation and motion of the body with the primary contributions being an ultra-low power ozone sensor, an volatile organic compounds sensor, spirometer, and the integration of these and other sensors in a multimodal sensing platform. The measured environmental parameters include ambient ozone concentration, temperature, and relative humidity. Our array of sensors also assesses heart rate via photoplethysmography and electrocardiography, respiratory rate via photoplethysmography, skin impedance, three-axis acceleration, wheezing via a microphone, and expiratory airflow. The sensors on the wristband, chest patch, and spirometer consume 0.83, 0.96, and 0.01 milliwatts respectively. The data from each sensor is continually streamed to a peripheral data aggregation device and is subsequently transferred to a dedicated server for cloud storage. Future work includes reducing the power consumption of the system-on-chip including radio to reduce the entirety of each described system in the sub-milliwatt range. PMID:27249840
Dieffenderfer, James; Goodell, Henry; Mills, Steven; McKnight, Michael; Yao, Shanshan; Lin, Feiyan; Beppler, Eric; Bent, Brinnae; Lee, Bongmook; Misra, Veena; Zhu, Yong; Oralkan, Omer; Strohmaier, Jason; Muth, John; Peden, David; Bozkurt, Alper
2016-09-01
We present our efforts toward enabling a wearable sensor system that allows for the correlation of individual environmental exposures with physiologic and subsequent adverse health responses. This system will permit a better understanding of the impact of increased ozone levels and other pollutants on chronic asthma conditions. We discuss the inefficiency of existing commercial off-the-shelf components to achieve continuous monitoring and our system-level and nano-enabled efforts toward improving the wearability and power consumption. Our system consists of a wristband, a chest patch, and a handheld spirometer. We describe our preliminary efforts to achieve a submilliwatt system ultimately powered by the energy harvested from thermal radiation and motion of the body with the primary contributions being an ultralow-power ozone sensor, an volatile organic compounds sensor, spirometer, and the integration of these and other sensors in a multimodal sensing platform. The measured environmental parameters include ambient ozone concentration, temperature, and relative humidity. Our array of sensors also assesses heart rate via photoplethysmography and electrocardiography, respiratory rate via photoplethysmography, skin impedance, three-axis acceleration, wheezing via a microphone, and expiratory airflow. The sensors on the wristband, chest patch, and spirometer consume 0.83, 0.96, and 0.01 mW, respectively. The data from each sensor are continually streamed to a peripheral data aggregation device and are subsequently transferred to a dedicated server for cloud storage. Future work includes reducing the power consumption of the system-on-chip including radio to reduce the entirety of each described system in the submilliwatt range.
[Design of a pulse oximeter used to low perfusion and low oxygen saturation].
Tan, Shuangping; Ai, Zhiguang; Yang, Yuxing; Xie, Qingguo
2013-05-01
This paper presents a new pulse oximeter used to low perfusion at 0.125% and wide oxygen saturation range from 35% to 100%. In order to acquire the best PPG signals, the variable gain amplifier(VGA) is adopted in hardware. The self-developed auto-correlation modeling method is adopted in software and it can extract pulse wave from low perfusion signals and remove motion artifacts partly.
Physiological Strain During Load Carrying: Effects of Mass and Type of Backpack
2001-05-01
load did not significantly increase the EMG signal of the trapezius shoulder muscle (pars descenders). While walking, load carrying significantly...descending part of the right trapezius muscle was measured with two surface silver-silver chloride electrodes (PPG, Hellige), positioned on the distal...values using a previously determined RMS versus force relationship. This calibration curve between RMS of the EMG of the trapezius muscle and the force
Javed, Faizan; Middleton, Paul M; Malouf, Philip; Chan, Gregory S H; Savkin, Andrey V; Lovell, Nigel H; Steel, Elizabeth; Mackie, James
2010-09-01
This study investigates the peripheral circulatory and autonomic response to volume withdrawal in haemodialysis based on spectral analysis of photoplethysmographic waveform variability (PPGV). Frequency spectrum analysis was performed on the baseline and pulse amplitude variabilities of the finger infrared photoplethysmographic (PPG) waveform and on heart rate variability extracted from the ECG signal collected from 18 kidney failure patients undergoing haemodialysis. Spectral powers were calculated from the low frequency (LF, 0.04-0.145 Hz) and high frequency (HF, 0.145-0.45 Hz) bands. In eight stable fluid overloaded patients (fluid removal of >2 L) not on alpha blockers, progressive reduction in relative blood volume during haemodialysis resulted in significant increase in LF and HF powers of PPG baseline and amplitude variability (P < 0.01), when expressed in mean-scaled units. The augmentation of LF powers in PPGV during haemodialysis may indicate the recovery and possibly further enhancement of peripheral sympathetic vascular modulation subsequent to volume unloading, whilst the increase in respiratory HF power in PPGV is most likely a sign of preload reduction. Spectral analysis of finger PPGV may provide valuable information on the autonomic vascular response to blood volume reduction in haemodialysis, and can be potentially utilized as a non-invasive tool for assessing peripheral circulatory control during routine dialysis procedure.
Designing and Constructing an Optical Monitoring System of Blood Supply to Tissues under Pressure.
Hadi, Akbari; Amin, Younessi Heravi Mohammad
2012-04-01
Reduced blood flow due to obstruction is in most cases a primary factor in pressure ulcer formation and creation of bedsores. The aim of this study is to design and manufacture a care system for tissue under pressure, based on variations in blood flow at different depths of tissue. In the manufacture of the system two infrared light transmitters and receivers were located between 5 and 10 mm depth to measure the flow of blood at different in the under- pressure heel tissue. In addition, blood flow was evaluated in an unloaded and loaded condition, with 30 mmHg and 60.0 mmHg. A total of 15 people participated with a mean age of 50. Of these 15; 9 (60%) were men and 6 (40%) were women. Primary measurement results showed different individual differences in variation of blood flow in the tissue. To study signal amplitude changes significantly influenced by external pressure the PPG, P-value was measured. It was noted that there were significant changes in PPG signal amplitude during loading both pressures of 30 and 60 mmHg. Further development of this system would be possible with the use of a more flexible probe and by using a stronger optical receiver and transmitter to access more depth.
Sheppard, Justine Joan; Malandraki, Georgia A; Pifer, Paula; Cuff, Jill; Troche, Michelle; Hemsley, Bronwyn; Balandin, Susan; Mishra, Avinash; Hochman, Roberta
2017-10-01
Risk assessments are needed to identify adults with intellectual and developmental disability (IDD) at high risk of choking and pneumonia. To describe the development and validation of the Choking Risk Assessment (CRA) and the Pneumonia Risk Assessment (PRA) for adults with IDD. Test items were identified through literature review and focus groups. Five-year retrospective chart reviews identified a positive choking group (PCG), a negative choking group (NCG), a positive pneumonia group (PPG), and a negative pneumonia group (NPG). Participants were tested with the CRA and PRA by clinicians blind to these testing conditions. The CRA and PRA differentiated the PCG (n=93) from the NCG (n=526) and the PPG (n=63) from the NPG (n=209) with high specificity (0.91 and 0.92 respectively) and moderate to average sensitivity (0.53 and 0.62 respectively). Further analyses revealed associations between clinical diagnoses of dysphagia and choking (p=0.043), and pneumonia (p<0.001). The CRA and PRA are reliable, valid risk indicators for choking and pneumonia in adults with IDD. Precautions for mitigating choking and pneumonia risks can be applied selectively thus avoiding undue impacts on quality of life and unnecessary interventions for low risk individuals. Copyright © 2017 Elsevier Ltd. All rights reserved.
Dehkordi, Parastoo; Garde, Ainara; Karlen, Walter; Petersen, Christian L; Wensley, David; Dumont, Guy A; Mark Ansermino, J
2016-02-01
Individuals with sleep disordered breathing (SDB) can experience changes in automatic cardiac regulation as a result of frequent sleep fragmentation and disturbance in normal respiration and oxygenation that accompany most apnea/hypopnea events. In adults, these changes are reflected in enhanced sympathetic and reduced parasympathetic activity. In this study, we examined the autonomic cardiac regulation in children with and without SDB, through spectral and detrended fluctuation analysis (DFA) of pulse rate variability (PRV). PRV was measured from pulse-to-pulse intervals (PPIs) of the photoplethysmogram (PPG) recorded from 160 children using the Phone Oximeter(™) in the standard setting of overnight polysomnography. Spectral analysis of PRV showed the cardiac parasympathetic index (high frequency, HF) was lower (p < 0.01) and cardiac sympathetic indices (low frequency, LF and LF/HF ratio) were higher (p < 0.01) during apnea/hypopnea events for more than 95% of children with SDB. DFA showed the short- and long-range fluctuations of heart rate were more strongly correlated in children with SDB compared to children without SDB. These findings confirm that the analysis of the PPG recorded using the Phone Oximeter(™) could be the basis for a new screening tool for assessing PRV in non-clinical environment.
Bacterial chemotaxis along vapor-phase gradients of naphthalene.
Hanzel, Joanna; Harms, Hauke; Wick, Lukas Y
2010-12-15
The role of bacterial growth and translocation for the bioremediation of organic contaminants in the vadose zone is poorly understood. Whereas air-filled pores restrict the mobility of bacteria, diffusion of volatile organic compounds in air is more efficient than in water. Past research, however, has focused on chemotactic swimming of bacteria along gradients of water-dissolved chemicals. In this study we tested if and to what extent Pseudomonas putida PpG7 (NAH7) chemotactically reacts to vapor-phase gradients forming above their swimming medium by the volatilization from a spot source of solid naphthalene. The development of an aqueous naphthalene gradient by air-water partitioning was largely suppressed by means of activated carbon in the agar. Surprisingly, strain PpG7 was repelled by vapor-phase naphthalene although the steady state gaseous concentrations were 50-100 times lower than the aqueous concentrations that result in positive chemotaxis of the same strain. It is thus assumed that the efficient gas-phase diffusion resulting in a steady, and possibly toxic, naphthalene flux to the cells controlled the chemotactic reaction rather than the concentration to which the cells were exposed. To our knowledge this is the first demonstration of apparent chemotactic behavior of bacteria in response to vapor-phase effector gradients.
NASA Astrophysics Data System (ADS)
Rita, Novia; Mursyidah, Syahindra, Michael
2018-03-01
When drilling, if the hydrostatic pressure is higher than formation pressure (fracture pressure) it will cause lost circulation during cementing process. To solve this problem, hydrostatic pressure of slurry can be decreased by lowering the slurry density by using some additives. Ceramic Hollow Spheres (CHS) is lightweight additive. This additive comes with low specific gravity so it can lowered the slurry density. When the low-density slurry used in cementing process, it can prevent low circulation and fractured formation caused by cement itself. Class G cement is used in this experiment with the standard density of this slurry is 15.8 ppg. With the addition of CHS, slurry density lowered to 12.5 ppg. CHS not only used to lower the slurry density, it also used to make the same properties with the standard slurry even the density has been lowered. Both thickening time and compressive strength have not change if the CHS added to the slurry. With addition of CHS, thickening time at 70 Bc reached in 03 hours 12 minutes. For the compressive strength, 2000 psi reached in 07 hours 07 minutes. Addition of CHS can save more time in cementing process of X formation.
De Sarro, Giovambattista; Chimirri, Alba; Meldrum, Brian S
2002-09-06
We report the anticonvulsant action in DBA/2 mice of two mGlu Group III receptor agonists: (R,S)-4-phosphonophenylglycine, (R,S)-PPG, a compound with moderate mGlu8 selectivity, and of (1S,3R,4S)-1-aminocyclopentane-1,2,4-tricarboxylic acid, ACPT-1, a selective agonist for mGlu4alpha receptors. Both compounds, given intracerebroventricularly at doses which did not show marked anticonvulsant activity, produced a consistent shift to the left of the dose-response curves (i.e. enhanced the anticonvulsant properties) of 1-(4'-aminophenyl)-3,5-dihydro-7,8-dimethoxy-4H-2,3-benzodiazepin-4-one hydrochloride, CFM-2, a noncompetitive AMPA receptor antagonist, and 3-((+/-)-2-carboxypiperazin-4-yl)-1-phosphonic acid, CPPene, a competitive NMDA receptor antagonist, in DBA/2 mice. In addition, (R,S)-PPG and ACPT-1 administered intracerebroventricularly prolonged the time course of the anticonvulsant properties of CFM-2 (33 micromol/kg, i.p.) and CPPene (3.3 micromol/kg, i.p.) administered intraperitoneally. We conclude that modest reduction of synaptic glutamate release by activation of Group III metabotropic receptors potentiates the anticonvulsant effect of AMPA and NMDA receptor blockade. Copyright 2002 Elsevier Science B.V.
Mya, Khine Y; Lin, Esther M J; Gudipati, Chakravarthy S; Gose, Halima B A S; He, Chaobin
2010-07-22
Poly(hexafluorobutyl methacrylate) (PHFBMA) homopolymer was synthesized by reversible addition-fragmentation chain transfer (RAFT)-mediated living radical polymerization in the presence of cyano-2-propyl dithiobenzoate (CPDB) RAFT agent. A block copolymer of PHFBMA-poly(propylene glycol acrylate) (PHFBMA-b-PPGA) with dangling poly(propylene glycol) (PPG) side chains was then synthesized by using CPDB-terminated PHFBMA as a macro-RAFT agent. The amphiphilic properties and self-assembly of PHFBMA-b-PPGA block copolymer in aqueous solution were investigated by dynamic and static light scattering (DLS and SLS) studies, in combination with fluorescence spectroscopy and transmission electron microscopy (TEM). Although PPG shows moderately hydrophilic character, the formation of nanosize polymeric micelles was confirmed by fluorescence and TEM studies. The low value of the critical aggregation concentration exhibited that the tendency for the formation of copolymer aggregates in aqueous solution was very high due to the strong hydrophobicity of the PHFBMA(145)-b-PPGA(33) block copolymer. The combination of DLS and SLS measurements revealed the existence of micellar aggregates in aqueous solution with an association number of approximately 40 +/- 7 for block copolymer micelles. It was also found in TEM observation that there are 40-50 micelles accumulated into one aggregate and these micelles are loosely packed inside the aggregate.
2010-11-01
hypovolemia in the prehospital environment. Photoplethysmogram waveforms and basic vital signs were recorded in trauma patients during prehospital...transport. Retrospectively, we used automated algorithms to select patient records with all five basic vital signs and 45 s or longer continuous, clean PPG... basic vital signs by applying multivariate regression. In 344 patients, RIWV max-min yielded areas under the ROC curves (AUCs) not significantly better
1996-02-01
participating companies: Reichhold Chemicals, Clark-Schwebel, PPG Industries, Interplastic Corp., Owens - Corning , and TPI, Inc .. Tagging Materials Five...cellophane film (# 95080906). The eddy current testing of samples with MnZn ferrite tagging from Owens - Corning showed that the response of the sample...example, consider the specimen obtained from Owens - Corning sample A (MnZn ferrite tagging) shown in the sixth row of Table 3. The naturaI frequency
2011-02-01
Methods of Measurement All subjects were instrumented with 3 Nonin pulse oximeter sensors ( Nonin Medical, Plymouth, MN; OEM III module, 16-bit data...ring finger of the left hand. Unlike standard pulse oximeters that have autocalibration capability, the Nonin pulse oximeter did not alter the raw...stroke volume and are therefore presented as percentage change from baseline levels. The PPG and Spo2 values from the Nonin pulse oxime- ter sensors were
Di Santo, Pietro; Harnett, David T.; Simard, Trevor; Ramirez, F. Daniel; Pourdjabbar, Ali; Yousef, Altayyeb; Moreland, Robert; Bernick, Jordan; Wells, George; Dick, Alexander; Le May, Michel; Labinaz, Marino; So, Derek; Motazedian, Pouya; Jung, Richard G.; Chandrasekhar, Jaya; Mehran, Roxana; Chong, Aun-Yeong
2018-01-01
BACKGROUND: Radial artery access is commonly performed for coronary angiography and invasive hemodynamic monitoring. Despite limitations in diagnostic accuracy, the modified Allen test (manual occlusion of radial and ulnar arteries followed by release of the latter and assessment of palmar blush) is used routinely to evaluate the collateral circulation to the hand and, therefore, to determine patient eligibility for radial artery access. We sought to evaluate whether a smartphone application may provide a superior alternative to the modified Allen test. METHODS: We compared the modified Allen test with a smartphone heart rate–monitoring application (photoplethysmography readings detected using a smartphone camera lens placed on the patient’s index finger) in patients undergoing a planned cardiac catheterization. Test order was randomly assigned in a 1:1 fashion. All patients then underwent conventional plethysmography of the index finger, followed by Doppler ultrasonography of the radial and ulnar arteries (the diagnostic standard). The primary outcome was diagnostic accuracy of the heart rate–monitoring application. RESULTS: Among 438 patients who were included in the study, we found that the heart rate–monitoring application had a superior diagnostic accuracy compared with the modified Allen test (91.8% v. 81.7%, p = 0.002), attributable to its greater specificity (93.0% v. 82.8%, p = 0.001). We also found that this application had greater diagnostic accuracy for assessment of radial or ulnar artery patency in the ipsilateral and contralateral wrist (94.0% v. 84.0%, p < 0.001). INTERPRETATION: A smartphone application used at the bedside was diagnostically superior to traditional physical examination for confirming ulnar patency before radial artery access. This study highlights the potential for smartphone-based diagnostics to aid in clinical decision-making at the patient’s bedside. Trial registration: Clinicaltrials.gov, no. NCT02519491. PMID:29615421
Høyer, Christian; Nielsen, Nikolaj Schandorph; Jordansen, Malene Kragh Overvad; Zacho, Helle Damgaard
2017-12-01
To examine the interchangeability of two methods for distal pressure measurement based on photoplethysmography using a truncated or full display of the arterial inflow curve, respectively. Toe and ankle pressures were obtained from 69 patients suspected of peripheral arterial disease (PAD). Observer reproducibility of the curve readings was examined by blinded reassessment of the pressure curves in a randomly selected subgroup (60 limbs). There were no significant differences in mean pressures between the two methods (p for all > .455). The limits of agreement for the differences were -15.0-15.4 mmHg for right toe pressures, -16.3-16.2 mmHg for left toe pressures, -14.2-15.7 mmHg for right ankle pressures, and -18.3-17.7 mmHg for left ankle pressures. Correlation analysis revealed intraclass correlation coefficients ≥0.960 for all measuring sites. Cohen's Kappa showed excellent agreement in diagnostic classification, with κ = 0.930 for the diagnosis of PAD and perfect agreement in the diagnosis of critical limb ischemia (κ = 1.000). The analysis of intra-observer variation for curve reading showed limits of agreement of -3.9-4.0 for toe pressures and -7.6-7.7 for ankle pressures for the method involving truncated display and -3.1-3.2 for toe pressures and -6.3-8.6 for ankle pressures for the method involving full display of the signal. The present study shows minimal differences in diagnostic classification, as well as in ankle and toe pressures, between the full display and the truncated display of the photoplethysmographic pulse signal. Furthermore, the inter-observer variation was low for both of the photoplethysmographic methods investigated.
The effect of pre-dive ingestion of dark chocolate on endothelial function after a scuba dive.
Theunissen, Sigrid; Balestra, Costantino; Boutros, Antoine; De Bels, David; Guerrero, François; Germonpré, Peter
2015-03-01
The aim of the study was to observe the effects of dark chocolate on endothelial function after scuba diving. Forty-two male scuba divers were divided into two groups: a control (n=21) and a chocolate group (n=21). They performed a 33-metres deep scuba-air dive for 20 minutes in a diving pool (Nemo 33, Brussels). Water temperature was 33⁰C. The chocolate group ingested 30 g of dark chocolate (86% cocoa) 90 minutes before the dive. Flow-mediated dilatation (FMD), digital photoplethysmography and nitric oxide (NO) and peroxynitrites (ONOO-) levels were measured before and after the scuba dive in both groups. A significant decrease in FMD was observed in the control group after the dive (91±7% (mean±95% confidence interval) of pre-dive values; P<0.001) while it was increased in the chocolate group (105±5% of pre-dive values; P<0.001). No difference in digital photoplethysmography was observed between before and after the dives. No variation of circulating NO level was observed in the control group whereas an increase was shown in the chocolate group (154±73% of pre-dive values; P=0.04). A significant reduction in ONOO- was observed in the control group (84±12% of pre-dive values; P=0.003) whereas no variation was shown after the dive with chocolate intake (100±28% of pre-dive values; ns). Ingestion of 30 g of dark chocolate 90 minutes before scuba diving prevented post-dive endothelial dysfunction, as the antioxidants contained in dark chocolate probably scavenge free radicals.
Dark chocolate reduces endothelial dysfunction after successive breath-hold dives in cool water.
Theunissen, Sigrid; Schumacker, Julie; Guerrero, François; Tillmans, Frauke; Boutros, Antoine; Lambrechts, Kate; Mazur, Aleksandra; Pieri, Massimo; Germonpré, Peter; Balestra, Costantino
2013-12-01
The aim of this study is to observe the effects of dark chocolate on endothelial function after a series of successive apnea dives in non-thermoneutral water. Twenty breath-hold divers were divided into two groups: a control group (8 males and 2 females) and a chocolate group (9 males and 1 female). The control group was asked to perform a series of dives to 20 m adding up to 20 min in the quiet diving pool of Conflans-Ste-Honorine (Paris, France), water temperature was 27 °C. The chocolate group performed the dives 1 h after ingestion of 30 g of dark chocolate. Flow-mediated dilatation (FMD), digital photoplethysmography, nitric oxide (NO), and peroxynitrite ONOO−) levels were measured before and after each series of breath-hold dives. A significant decrease in FMD was observed in the control group after the dives (95.28 ± 2.9 % of pre-dive values, p < 0.001) while it was increased in the chocolate group (104.1 ± 2.9 % of pre-dive values, p < 0.01). A decrease in the NO level was observed in the control group (86.76 ± 15.57 %, p < 0.05) whereas no difference was shown in the chocolate group (98.44 ± 31.86 %, p > 0.05). No differences in digital photoplethysmography and peroxynitrites were observed between before and after the dives. Antioxidants contained in dark chocolate scavenge free radicals produced during breath-hold diving. Ingestion of 30 g of dark chocolate 1 h before the dive can thus prevent endothelial dysfunction which can be observed after a series of breath-hold dives.
Di Santo, Pietro; Harnett, David T; Simard, Trevor; Ramirez, F Daniel; Pourdjabbar, Ali; Yousef, Altayyeb; Moreland, Robert; Bernick, Jordan; Wells, George; Dick, Alexander; Le May, Michel; Labinaz, Marino; So, Derek; Motazedian, Pouya; Jung, Richard G; Chandrasekhar, Jaya; Mehran, Roxana; Chong, Aun-Yeong; Hibbert, Benjamin
2018-04-03
Radial artery access is commonly performed for coronary angiography and invasive hemodynamic monitoring. Despite limitations in diagnostic accuracy, the modified Allen test (manual occlusion of radial and ulnar arteries followed by release of the latter and assessment of palmar blush) is used routinely to evaluate the collateral circulation to the hand and, therefore, to determine patient eligibility for radial artery access. We sought to evaluate whether a smartphone application may provide a superior alternative to the modified Allen test. We compared the modified Allen test with a smartphone heart rate-monitoring application (photoplethysmography readings detected using a smartphone camera lens placed on the patient's index finger) in patients undergoing a planned cardiac catheterization. Test order was randomly assigned in a 1:1 fashion. All patients then underwent conventional plethysmography of the index finger, followed by Doppler ultrasonography of the radial and ulnar arteries (the diagnostic standard). The primary outcome was diagnostic accuracy of the heart rate-monitoring application. Among 438 patients who were included in the study, we found that the heart rate-monitoring application had a superior diagnostic accuracy compared with the modified Allen test (91.8% v. 81.7%, p = 0.002), attributable to its greater specificity (93.0% v. 82.8%, p = 0.001). We also found that this application had greater diagnostic accuracy for assessment of radial or ulnar artery patency in the ipsilateral and contralateral wrist (94.0% v. 84.0%, p < 0.001). A smartphone application used at the bedside was diagnostically superior to traditional physical examination for confirming ulnar patency before radial artery access. This study highlights the potential for smartphone-based diagnostics to aid in clinical decision-making at the patient's bedside. Trial registration: Clinicaltrials.gov, no. NCT02519491. © 2018 Joule Inc. or its licensors.
NASA Astrophysics Data System (ADS)
Deglint, Jason; Chung, Audrey G.; Chwyl, Brendan; Amelard, Robert; Kazemzadeh, Farnoud; Wang, Xiao Yu; Clausi, David A.; Wong, Alexander
2016-03-01
Traditional photoplethysmographic imaging (PPGI) systems use the red, green, and blue (RGB) broadband measurements of a consumer digital camera to remotely estimate a patients heart rate; however, these broadband RGB signals are often corrupted by ambient noise, making the extraction of subtle fluctuations indicative of heart rate difficult. Therefore, the use of narrow-band spectral measurements can significantly improve the accuracy. We propose a novel digital spectral demultiplexing (DSD) method to infer narrow-band spectral information from acquired broadband RGB measurements in order to estimate heart rate via the computation of motion- compensated skin erythema fluctuation. Using high-resolution video recordings of human participants, multiple measurement locations are automatically identified on the cheeks of an individual, and motion-compensated broadband reflectance measurements are acquired at each measurement location over time via measurement location tracking. The motion-compensated broadband reflectance measurements are spectrally demultiplexed using a non-linear inverse model based on the spectral sensitivity of the camera's detector. A PPG signal is then computed from the demultiplexed narrow-band spectral information via skin erythema fluctuation analysis, with improved signal-to-noise ratio allowing for reliable remote heart rate measurements. To assess the effectiveness of the proposed system, a set of experiments involving human motion in a front-facing position were performed under ambient lighting conditions. Experimental results indicate that the proposed system achieves robust and accurate heart rate measurements and can provide additional information about the participant beyond the capabilities of traditional PPGI methods.
Yamada, Masatoshi; Zheng, Jian
2012-07-15
The (239+240)Pu concentrations and (240)Pu/(239)Pu atom ratios were determined by alpha spectrometry and inductively coupled plasma mass spectrometry for seawater samples from two stations, one at the equator and the other in the equatorial South Pacific. To better understand the fate of Pu isotopes, this study dealt with the contribution of the close-in fallout Pu from the Pacific Proving Grounds (PPG) in water columns of the Pacific Ocean. The (239)Pu, (240)Pu and (239+240)Pu inventories over the depth interval 0-3000 m at the equator station were 10.4, 8.9 and 19.3 Bq m(-2), respectively. Further, no noticeable difference was observed in (239)Pu, (240)Pu and (239+240)Pu inventories over the depth interval 0-3000 m between the two stations. The total (239+240)Pu inventories were significantly higher than the expected cumulative deposition density of global fallout. Water column (239+240)Pu inventories measured in this study were lower than those reported for comparable stations in the Geochemical Ocean Sections Study, indicating that these inventories have been decreasing at average rates of 0.89 ± 0.07 and 0.16 ± 0.07 Bq m(-2)yr(-1) at the equator and equatorial South Pacific stations, respectively, from 1973 to 1990. The obtained (240)Pu/(239)Pu atom ratios were higher than the mean global fallout ratio of 0.18. These high atom ratios proved the existence of close-in tropospheric fallout Pu from the PPG in the Marshall Islands. The (239+240)Pu inventories originating from the close-in fallout in the entire water column were estimated to be 11.1 Bq m(-2) at the equator station and 7.1 Bq m(-2) at the equatorial South Pacific Ocean station, and the relative percentages of close-in fallout Pu were 40% at the former and 34% at the latter. A significant amount of close-in fallout Pu originating from the PPG has been transported to deep layers below the 1000 m depth in the equatorial Pacific Ocean. Copyright © 2012 Elsevier B.V. All rights reserved.
2014-12-01
dengue hemorrhagic fever. In future work we will continue to evaluate the use of pulse wave forms to predict shock and will assess other...Index Three laboratory Phase I clinical trials have been completed to support a 510(k) application for FDA approval of the first prototype Pulse ... Oximeter with the CRI algorithm and capability for real-time continuous collection of photoplethymographic (PPG) analog signals. An FDA-cleared
Status of NC Primer Demonstration & Transition
2014-11-20
Camo Paint Scheme H-53 • Six a/c selected for demonstration of Hentzen 17176KEP FRCE • Full non-chromate coating stack-up demo – Hentzen...CCC • BUNO #: #163076 #163080 #164859 11 NC Primer Demos: Camo Paint Scheme F/A-18A-D • 13 a/c selected for demonstration of PPG-Deft 02-GN... Strippability 5. Dry Time (-23377) 6. Fluid Resistance (Skydrol) 7. Solvent Resistance 8. Thickness Tolerance 9. Application Method 10. Packaging (1K
Investigations on the influence of breathing on brain activity using optical sensors
NASA Astrophysics Data System (ADS)
Rao, Mandavilli M.; Blazek, Vladimir; Schmitt, Hans J.
1997-05-01
In recent years investigation and understanding of the brain activity is receiving much attention. Such investigations are generally confined to few select premier research institutions where expensive and sophisticated facilities like EEG, PET, FMRI, etc. are available. Of late optical sensors are receiving much attention for biomedical applications because they are relatively simple in construction, easy to use and comparatively inexpensive. Among the biomedical optical sensors, photophlethysmographic (PPG) measuring systems have a unique position. They function as transcutaneous registration of blood volume changes in the near skin blood vessels. By recording the signals from the supply to the left and right lobes of the brain in the cerebral cortex. The oxygen content in the arterary blood flow to the brain will naturally have an important role to play in the activity of the brain. It is suggested that by positioning sensitive temperature sensors in the nostrils of a subject, one could monitor his breathing activity. By recording the outputs rom these temperature sensor for several hours, it has been noticed that the breathing activity of a subject will change from one nostril to another periodically. Besides, it has also been observed that any sudden fluctuations in the breathing pattern is accompanied by changes in the blood flow to the brain as monitored by PPG optical sensors mounted on the temples of a subject. An attempt is made to understand such events.
Keikhosravi, Adib; Aghajani, Haleh; Zahedi, Edmond
2013-05-01
Endothelial dysfunction assessment has received considerable attention due to its potential in early screening of cardiovascular diseases. Since the seminal work by Celermajer in flow-mediated dilation (FMD) based on B-mode ultrasound measurement of the brachial artery dilation following limb ischemia, many attempts have been made toward applying this method to clinical, non-invasive endothelial dysfunction assessment. One major obstacle toward achieving this objective has been the relative high cost of the required setup and skilled manpower. Such limitations have prompted the investigation of other non-invasively accessible signals such as the photoplethysmogram (PPG) in relation to FMD. It is in the above context that this paper proposes to use a modified version of an existing differential model of the human upper vasculature in order to discriminate between healthy and diabetic subjects. PPG from 46 subjects (23 healthy and 23 diabetic) were utilized to identify the model parameters. Once the model parameters were identified, singular value decomposition was applied to reduce the number of features and increase the separability. Finally, a naive Bayes classifier resulted in an overall accuracy of 93.5% (Spec. 87.0% and Sens. 100%). Taking into account subjects' gender further improved the overall accuracy. It is thought that the application of the proposed method to endothelial dysfunction assessment may positively impact the deployment of FMD in clinical settings.
NASA Astrophysics Data System (ADS)
Duadi, Hamootal; Fixler, Dror
2015-05-01
Light reflectance and transmission from soft tissue has been utilized in noninvasive clinical measurement devices such as the photoplethysmograph (PPG) and reflectance pulse oximeter. Incident light on the skin travels into the underlying layers and is in part reflected back to the surface, in part transferred and in part absorbed. Most methods of near infrared (NIR) spectroscopy focus on the volume reflectance from a semi-infinite sample, while very few measure transmission. We have previously shown that examining the full scattering profile (angular distribution of exiting photons) provides more comprehensive information when measuring from a cylindrical tissue. Furthermore, an isobaric point was found which is not dependent on changes in the reduced scattering coefficient. The angle corresponding to this isobaric point depends on the tissue diameter. We investigated the role of multiple scattering and absorption on the full scattering profile of a cylindrical tissue. First, we define the range in which multiple scattering occurs for different tissue diameters. Next, we examine the role of the absorption coefficient in the attenuation of the full scattering profile. We demonstrate that the absorption linearly influences the intensity at each angle of the full scattering profile and, more importantly, the absorption does not change the position of the isobaric point. The findings of this work demonstrate a realistic model for optical tissue measurements such as NIR spectroscopy, PPG, and pulse oximetery.
Kavakcıoğlu, Berna; Tongul, Burcu; Tarhan, Leman
2017-03-01
In the present work, the partitioning behavior of menadione-induced superoxide dismutase (SOD; EC 1.15.1.1), an antioxidant enzyme that has various applications in the medical and cosmetic industries, from the white rot fungus Phanerochaete chrysosporium has been characterized on different types of aqueous two-phase systems (ATPSs) (poly(ethylene glycol)/polypropylene glycol (PEG/PPG)-dextran, PEG-salt and PPG-salt). PEG-salt combinations were found most optimal systems for the purification of SOD. The best partition conditions were found using the PEG-3350 24% and K 2 HPO 4 5% (w/w) with pH 7.0 at 25 °C. The partition coefficient of total SOD activity and total protein concentration observed in this system were 0.17 and 6.65, respectively, with the recovery percentage as 78.90% in the bottom phase and 13.17% in the top phase. The highest purification fold for SOD from P. chrysosporium was found as 6.04 in the bottom phase of PEG 3350%24 - K 2 HPO 4 %5 (w/w) system with pH 7.0. SOD purified from P. chrysosporium was determined to be a homodimer in its native state with a molecular weight of 60 ± 4 kDa. Consequently, simple and only one step PEG-salt ATPS system was developed for SOD purification from P. chrysosporium.
Effects of hydrogen sulfide on high glucose-induced glomerular podocyte injury in mice
Liu, Ye; Zhao, Huichen; Qiang, Ye; Qian, Guanfang; Lu, Shengxia; Chen, Jicui; Wang, Xiangdong; Guan, Qingbo; Liu, Yuantao; Fu, Yuqin
2015-01-01
The aim of this study was to assess the effects of hydrogen sulfide on high glucose-induced mouse podocyte (MPC) injury and the underlying mechanisms. Mouse podocytes were randomly divided into 4 groups, including high glucose (HG), normal glucose (NG), normal glucose + DL-propargylglycine (PPG), and high glucose + NaHS (HG + NaHS) groups for treatment. Then, ZO-2, nephrin, β-catenin, and cystathionine γ-lyase (CSE) protein expression levels were determined by western blot. We found that high glucose significantly reduced nephrin, ZO-2, and CSE expression levels (P<0.05), and overtly elevated β-catenin amounts (P<0.05), in a time-dependent manner. Likewise, PPG at different concentrations in normal glucose resulted in significantly lower CSE, ZO-2, and nephrin levels (P<0.05), and increased β-catenin amounts (P<0.05). Interestingly, significantly increased ZO-2 and nephrin levels, and overtly reduced β-catenin amounts were observed in the HG + NaHS group compared with HG treated cells (P<0.01). Compared with NG treated cells, decreased ZO-2 and nephrin levels and higher β-catenin amounts were obtained in the HG + NaHS group. In conclusion,CSE downregulation contributes to hyperglycemia induced podocyte injury, which is alleviated by exogenous H2S possibly through ZO-2 upregulation and the subsequent suppression of Wnt/β-catenin pathway. PMID:26261567
Dickson, Sylvia; Gallagher, Julie; McIntyre, Lorna; Suter, Andy; Tan, Jen
2004-01-01
An open study was carried out to assess, primarily, the safety and tolerability of Aesculus hippocastanum in the treatment of CVI. Patients underwent 8 consecutive weeks of treatment and were asked to take one 50 mg Aesculus hippocastanum tablet, twice daily. In total, 91 adverse events were reported, of which only 4 were rated as probably related to the study drug. Patients judged the tolerability of the study medication in the majority of the cases at visits 2 and 3 (90 and 95%, respectively) to be "good" or "fairly good." Only 2 patients rated tolerability as poor at visit 3. For each of the symptoms investigated the difference in the median value between baseline and visit 3 was found to be statistically significant and both the ankle and lower leg circumference decreased. The PPG measurements were rejected after analysis since validation measurements carried out after the trial showed that the PPG technique had an internal error of around 30%. Nevertheless, the majority of patients rated efficacy to be "very good" or "good," with only 10 patients reporting no effect by the end of the study. The results of this study indicate that Aesculaforce 50 mg tablets are a safe, well-tolerated and efficacious treatment for Widmer stage I and II CVI.
Fixed combination of repaglinide and metformin in the management of type 2 diabetes
Moses, Robert
2009-01-01
Treatment to target fasting blood glucose (FBG), postprandial glucose (PPG) and HbA1c are essential in the management of type 2 diabetes to reduce the risk of vascular complications. Early combination therapy with oral agents is increasingly being seen as important to achieve this. Repaglinide, a rapid-acting insulin secretagogue, targets PPG, and metformin, an insulin sensitizer, targets FBG. Because of their complementary modes of action these therapies are frequently given as combination therapy in separate tablets. To overcome the issues with adherence to multiple tablets, repaglinide and metformin are now available in a fixed-dose combination (FDC). Repaglinide/metformin FDC is bioequivalent to each tablet given separately, suggesting that the efficacy and safety profile is similar. There is no effect of food on repaglinide when in the FDC. Repaglinide/metformin FDC is as effective in reducing HbA1c and FBG whether given twice or three times daily, with a similar safety profile. Repaglinide/metformin FDC twice daily is as effective in reducing HbA1c and FBG as rosiglitazone/metformin FDC with a similar safety profile, but unlike the rosiglitazone/metformin FDC, repaglinide/metformin FDC improves the lipid profile. Repaglinide/metformin FDC represents a new option in the pursuit of achieving glucose targets and reducing vascular risk in type 2 diabetes, with the advantage of improving adherence. PMID:21437123
Li, Xu; Mao, Xiao-Bo; Hei, Ren-Yi; Zhang, Zhi-Bin; Wen, Li-Ting; Zhang, Peng-Zhi; Qiu, Jian-Hua; Qiao, Li
2011-01-01
A reduction in cochlear blood flow plays an essential role in noise-induced hearing loss (NIHL). The timely regulation of cochlear perfusion determines the progression and prognosis of NIHL. Hydrogen sulfide (H(2)S) has attracted increasing interest as a vasodilator in cardiovascular systems. This study identified the role of H(2)S in cochlear blood flow regulation and noise protection. The gene and protein expression of the H(2)S synthetase cystathionine-γ-lyase (CSE) in the rat cochlea was examined using immunofluorescence and real-time PCR. Cochlear CSE mRNA levels varied according to the duration of noise exposure. A chronic intracochlear infusion model was built and artificial perilymph (AP), NaHS or DL-propargylglycine (PPG) were locally administered. Local sodium hydrosulfide (NaHS) significantly increased cochlear perfusion post-noise exposure. Cochlear morphological damage and hearing loss were alleviated in the NaHS group as measured by conventional auditory brainstem response (ABR), cochlear scanning electron microscope (SEM) and outer hair cell (OHC) count. The highest percentage of OHC loss occurred in the PPG group. Our results suggest that H(2)S plays an important role in the regulation of cochlear blood flow and the protection against noise. Further studies may identify a new preventive and therapeutic perspective on NIHL and other blood supply-related inner ear diseases.
Fixed combination of repaglinide and metformin in the management of type 2 diabetes.
Moses, Robert
2009-06-24
Treatment to target fasting blood glucose (FBG), postprandial glucose (PPG) and HbA(1c) are essential in the management of type 2 diabetes to reduce the risk of vascular complications. Early combination therapy with oral agents is increasingly being seen as important to achieve this. Repaglinide, a rapid-acting insulin secretagogue, targets PPG, and metformin, an insulin sensitizer, targets FBG. Because of their complementary modes of action these therapies are frequently given as combination therapy in separate tablets. To overcome the issues with adherence to multiple tablets, repaglinide and metformin are now available in a fixed-dose combination (FDC). Repaglinide/metformin FDC is bioequivalent to each tablet given separately, suggesting that the efficacy and safety profile is similar. There is no effect of food on repaglinide when in the FDC. Repaglinide/metformin FDC is as effective in reducing HbA(1c) and FBG whether given twice or three times daily, with a similar safety profile. Repaglinide/metformin FDC twice daily is as effective in reducing HbA(1c) and FBG as rosiglitazone/metformin FDC with a similar safety profile, but unlike the rosiglitazone/metformin FDC, repaglinide/metformin FDC improves the lipid profile. Repaglinide/metformin FDC represents a new option in the pursuit of achieving glucose targets and reducing vascular risk in type 2 diabetes, with the advantage of improving adherence.
Real time reconstruction of quasiperiodic multi parameter physiological signals
NASA Astrophysics Data System (ADS)
Ganeshapillai, Gartheeban; Guttag, John
2012-12-01
A modern intensive care unit (ICU) has automated analysis systems that depend on continuous uninterrupted real time monitoring of physiological signals such as electrocardiogram (ECG), arterial blood pressure (ABP), and photo-plethysmogram (PPG). These signals are often corrupted by noise, artifacts, and missing data. We present an automated learning framework for real time reconstruction of corrupted multi-parameter nonstationary quasiperiodic physiological signals. The key idea is to learn a patient-specific model of the relationships between signals, and then reconstruct corrupted segments using the information available in correlated signals. We evaluated our method on MIT-BIH arrhythmia data, a two-channel ECG dataset with many clinically significant arrhythmias, and on the CinC challenge 2010 data, a multi-parameter dataset containing ECG, ABP, and PPG. For each, we evaluated both the residual distance between the original signals and the reconstructed signals, and the performance of a heartbeat classifier on a reconstructed ECG signal. At an SNR of 0 dB, the average residual distance on the CinC data was roughly 3% of the energy in the signal, and on the arrhythmia database it was roughly 16%. The difference is attributable to the large amount of diversity in the arrhythmia database. Remarkably, despite the relatively high residual difference, the classification accuracy on the arrhythmia database was still 98%, indicating that our method restored the physiologically important aspects of the signal.