Yang, Guo Liang; Aziz, Aamer; Narayanaswami, Banukumar; Anand, Ananthasubramaniam; Lim, C C Tchoyoson; Nowinski, Wieslaw Lucjan
2005-01-01
A new method has been developed for multimedia enhancement of electronic teaching files created by using the standard protocols and formats offered by the Medical Imaging Resource Center (MIRC) project of the Radiological Society of North America. The typical MIRC electronic teaching file consists of static pages only; with the new method, audio and visual content may be added to the MIRC electronic teaching file so that the entire image interpretation process can be recorded for teaching purposes. With an efficient system for encoding the audiovisual record of on-screen manipulation of radiologic images, the multimedia teaching files generated are small enough to be transmitted via the Internet with acceptable resolution. Students may respond with the addition of new audio and visual content and thereby participate in a discussion about a particular case. MIRC electronic teaching files with multimedia enhancement have the potential to augment the effectiveness of diagnostic radiology teaching. RSNA, 2005.
Migration of the digital interactive breast-imaging teaching file
NASA Astrophysics Data System (ADS)
Cao, Fei; Sickles, Edward A.; Huang, H. K.; Zhou, Xiaoqiang
1998-06-01
The digital breast imaging teaching file developed during the last two years in our laboratory has been used successfully at UCSF (University of California, San Francisco) as a routine teaching tool for training radiology residents and fellows in mammography. Building on this success, we have ported the teaching file from an old Pixar imaging/Sun SPARC 470 display system to our newly designed telemammography display workstation (Ultra SPARC 2 platform with two DOME Md5/SBX display boards). The old Pixar/Sun 470 system, although adequate for fast and high-resolution image display, is 4- year-old technology, expensive to maintain and difficult to upgrade. The new display workstation is more cost-effective and is also compatible with the digital image format from a full-field direct digital mammography system. The digital teaching file is built on a sophisticated computer-aided instruction (CAI) model, which simulates the management sequences used in imaging interpretation and work-up. Each user can be prompted to respond by making his/her own observations, assessments, and work-up decisions as well as the marking of image abnormalities. This effectively replaces the traditional 'show-and-tell' teaching file experience with an interactive, response-driven type of instruction.
Casimage project: a digital teaching files authoring environment.
Rosset, Antoine; Muller, Henning; Martins, Martina; Dfouni, Natalia; Vallée, Jean-Paul; Ratib, Osman
2004-04-01
The goal of the Casimage project is to offer an authoring and editing environment integrated with the Picture Archiving and Communication Systems (PACS) for creating image-based electronic teaching files. This software is based on a client/server architecture allowing remote access of users to a central database. This authoring environment allows radiologists to create reference databases and collection of digital images for teaching and research directly from clinical cases being reviewed on PACS diagnostic workstations. The environment includes all tools to create teaching files, including textual description, annotations, and image manipulation. The software also allows users to generate stand-alone CD-ROMs and web-based teaching files to easily share their collections. The system includes a web server compatible with the Medical Imaging Resource Center standard (MIRC, http://mirc.rsna.org) to easily integrate collections in the RSNA web network dedicated to teaching files. This software could be installed on any PACS workstation to allow users to add new cases at any time and anywhere during clinical operations. Several images collections were created with this tool, including thoracic imaging that was subsequently made available on a CD-Rom and on our web site and through the MIRC network for public access.
Yang, Guo-Liang; Lim, C C Tchoyoson
2006-08-01
Radiology education is heavily dependent on visual images, and case-based teaching files comprising medical images can be an important tool for teaching diagnostic radiology. Currently, hardcopy film is being rapidly replaced by digital radiological images in teaching hospitals, and an electronic teaching file (ETF) library would be desirable. Furthermore, a repository of ETFs deployed on the World Wide Web has the potential for e-learning applications to benefit a larger community of learners. In this paper, we describe a Singapore National Medical Image Resource Centre (SN.MIRC) that can serve as a World Wide Web resource for teaching diagnostic radiology. On SN.MIRC, ETFs can be created using a variety of mechanisms including file upload and online form-filling, and users can search for cases using the Medical Image Resource Center (MIRC) query schema developed by the Radiological Society of North America (RSNA). The system can be improved with future enhancements, including multimedia interactive teaching files and distance learning for continuing professional development. However, significant challenges exist when exploring the potential of using the World Wide Web for radiology education.
Using compressed images in multimedia education
NASA Astrophysics Data System (ADS)
Guy, William L.; Hefner, Lance V.
1996-04-01
The classic radiologic teaching file consists of hundreds, if not thousands, of films of various ages, housed in paper jackets with brief descriptions written on the jackets. The development of a good teaching file has been both time consuming and voluminous. Also, any radiograph to be copied was unavailable during the reproduction interval, inconveniencing other medical professionals needing to view the images at that time. These factors hinder motivation to copy films of interest. If a busy radiologist already has an adequate example of a radiological manifestation, it is unlikely that he or she will exert the effort to make a copy of another similar image even if a better example comes along. Digitized radiographs stored on CD-ROM offer marked improvement over the copied film teaching files. Our institution has several laser digitizers which are used to rapidly scan radiographs and produce high quality digital images which can then be converted into standard microcomputer (IBM, Mac, etc.) image format. These images can be stored on floppy disks, hard drives, rewritable optical disks, recordable CD-ROM disks, or removable cartridge media. Most hospital computer information systems include radiology reports in their database. We demonstrate that the reports for the images included in the users teaching file can be copied and stored on the same storage media as the images. The radiographic or sonographic image and the corresponding dictated report can then be 'linked' together. The description of the finding or findings of interest on the digitized image is thus electronically tethered to the image. This obviates the need to write much additional detail concerning the radiograph, saving time. In addition, the text on this disk can be indexed such that all files with user specified features can be instantly retrieve and combined in a single report, if desired. With the use of newer image compression techniques, hundreds of cases may be stored on a single CD-ROM depending on the quality of image required for the finding in question. This reduces the weight of a teaching file from that of a baby elephant to that of a single CD-ROM disc. Thus, with this method of teaching file preparation and storage the following advantages are realized: (1) Technically easier and less time consuming image reproduction. (2) Considerably less unwieldy and substantially more portable teaching files. (3) Novel ability to index files and then retrieve specific cases of choice based on descriptive text.
dos-Santos, M; Fujino, A
2012-01-01
Radiology teaching usually employs a systematic and comprehensive set of medical images and related information. Databases with representative radiological images and documents are highly desirable and widely used in Radiology teaching programs. Currently, computer-based teaching file systems are widely used in Medicine and Radiology teaching as an educational resource. This work addresses a user-centered radiology electronic teaching file system as an instance of MIRC compliant medical image database. Such as a digital library, the clinical cases are available to access by using a web browser. The system has offered great opportunities to some Radiology residents interact with experts. This has been done by applying user-centered techniques and creating usage context-based tools in order to make available an interactive system.
Development of an indexed integrated neuroradiology reports for teaching file creation
NASA Astrophysics Data System (ADS)
Tameem, Hussain Z.; Morioka, Craig; Bennett, David; El-Saden, Suzie; Sinha, Usha; Taira, Ricky; Bui, Alex; Kangarloo, Hooshang
2007-03-01
The decrease in reimbursement rates for radiology procedures has placed even more pressure on radiology departments to increase their clinical productivity. Clinical faculties have less time for teaching residents, but with the advent and prevalence of an electronic environment that includes PACS, RIS, and HIS, there is an opportunity to create electronic teaching files for fellows, residents, and medical students. Experienced clinicians, who select the most appropriate radiographic image, and clinical information relevant to that patient, create these teaching files. Important cases are selected based on the difficulty in determining the diagnosis or the manifestation of rare diseases. This manual process of teaching file creation is time consuming and may not be practical under the pressure of increased demands on the radiologist. It is the goal of this research to automate the process of teaching file creation by manually selecting key images and automatically extracting key sections from clinical reports and laboratories. The text report is then processed for indexing to two standard nomenclatures UMLS and RADLEX. Interesting teaching files can then be queried based on specific anatomy and findings found within the clinical reports.
Developing a radiology-based teaching approach for gross anatomy in the digital era.
Marker, David R; Bansal, Anshuman K; Juluru, Krishna; Magid, Donna
2010-08-01
The purpose of this study was to assess the implementation of a digital anatomy lecture series based largely on annotated, radiographic images and the utility of the Radiological Society of North America-developed Medical Imaging Resource Center (MIRC) for providing an online educational resource. A series of digital teaching images were collected and organized to correspond to lecture and dissection topics. MIRC was used to provide the images in a Web-based educational format for incorporation into anatomy lectures and as a review resource. A survey assessed the impressions of the medical students regarding this educational format. MIRC teaching files were successfully used in our teaching approach. The lectures were interactive with questions to and from the medical student audience regarding the labeled images used in the presentation. Eighty-five of 120 students completed the survey. The majority of students (87%) indicated that the MIRC teaching files were "somewhat useful" to "very useful" when incorporated into the lecture. The students who used the MIRC files were most likely to access the material from home (82%) on an occasional basis (76%). With regard to areas for improvement, 63% of the students reported that they would have benefited from more teaching files, and only 9% of the students indicated that the online files were not user friendly. The combination of electronic radiology resources available in lecture format and on the Internet can provide multiple opportunities for medical students to learn and revisit first-year anatomy. MIRC provides a user-friendly format for presenting radiology education files for medical students. 2010 AUR. Published by Elsevier Inc. All rights reserved.
Kamauu, Aaron W C; DuVall, Scott L; Robison, Reid J; Liimatta, Andrew P; Wiggins, Richard H; Avrin, David E
2006-01-01
Although digital teaching files are important to radiology education, there are no current satisfactory solutions for export of Digital Imaging and Communications in Medicine (DICOM) images from picture archiving and communication systems (PACS) in desktop publishing format. A vendor-neutral digital teaching file, the Radiology Interesting Case Server (RadICS), offers an efficient tool for harvesting interesting cases from PACS without requiring modifications of the PACS configurations. Radiologists push imaging studies from PACS to RadICS via the standard DICOM Send process, and the RadICS server automatically converts the DICOM images into the Joint Photographic Experts Group format, a common desktop publishing format. They can then select key images and create an interesting case series at the PACS workstation. RadICS was tested successfully against multiple unmodified commercial PACS. Using RadICS, radiologists are able to harvest and author interesting cases at the point of clinical interpretation with minimal disruption in clinical work flow. RSNA, 2006
Loehfelm, Thomas W; Prater, Adam B; Debebe, Tequam; Sekhar, Aarti K
2017-02-01
We digitized the radiography teaching file at Black Lion Hospital (Addis Ababa, Ethiopia) during a recent trip, using a standard digital camera and a fluorescent light box. Our goal was to photograph every radiograph in the existing library while optimizing the final image size to the maximum resolution of a high quality tablet computer, preserving the contrast resolution of the radiographs, and minimizing total library file size. A secondary important goal was to minimize the cost and time required to take and process the images. Three workers were able to efficiently remove the radiographs from their storage folders, hang them on the light box, operate the camera, catalog the image, and repack the radiographs back to the storage folder. Zoom, focal length, and film speed were fixed, while aperture and shutter speed were manually adjusted for each image, allowing for efficiency and flexibility in image acquisition. Keeping zoom and focal length fixed, which kept the view box at the same relative position in all of the images acquired during a single photography session, allowed unused space to be batch-cropped, saving considerable time in post-processing, at the expense of final image resolution. We present an analysis of the trade-offs in workflow efficiency and final image quality, and demonstrate that a few people with minimal equipment can efficiently digitize a teaching file library.
Do, Bao H; Wu, Andrew; Biswal, Sandip; Kamaya, Aya; Rubin, Daniel L
2010-11-01
Storing and retrieving radiology cases is an important activity for education and clinical research, but this process can be time-consuming. In the process of structuring reports and images into organized teaching files, incidental pathologic conditions not pertinent to the primary teaching point can be omitted, as when a user saves images of an aortic dissection case but disregards the incidental osteoid osteoma. An alternate strategy for identifying teaching cases is text search of reports in radiology information systems (RIS), but retrieved reports are unstructured, teaching-related content is not highlighted, and patient identifying information is not removed. Furthermore, searching unstructured reports requires sophisticated retrieval methods to achieve useful results. An open-source, RadLex(®)-compatible teaching file solution called RADTF, which uses natural language processing (NLP) methods to process radiology reports, was developed to create a searchable teaching resource from the RIS and the picture archiving and communication system (PACS). The NLP system extracts and de-identifies teaching-relevant statements from full reports to generate a stand-alone database, thus converting existing RIS archives into an on-demand source of teaching material. Using RADTF, the authors generated a semantic search-enabled, Web-based radiology archive containing over 700,000 cases with millions of images. RADTF combines a compact representation of the teaching-relevant content in radiology reports and a versatile search engine with the scale of the entire RIS-PACS collection of case material. ©RSNA, 2010
Radiology teaching file cases on the World Wide Web.
Scalzetti, E M
1997-08-01
The presentation of a radiographic teaching file on the World Wide Web can be enhanced by attending to principles of web design. Chief among these are appropriate control of page layout, minimization of the time required to download a page from the remote server, and provision for navigation within and among the web pages that constitute the site. Page layout is easily accomplished by the use of tables; column widths can be fixed to maintain an acceptable line length for text. Downloading time is minimized by rigorous editing and by optimal compression of image files; beyond this, techniques like preloading of images and specification of image width and height are also helpful. Navigation controls should be clear, consistent, and readily available.
Development and evaluation of oral reporting system for PACS.
Umeda, T; Inamura, K; Inamoto, K; Ikezoe, J; Kozuka, T; Kawase, I; Fujii, Y; Karasawa, H
1994-05-01
Experimental workstations for oral reporting and synchronized image filing have been developed and evaluated by radiologists and referring physicians. The file media is a 5.25-inch rewritable magneto-optical disk of 600-Mb capacity whose file format is in accordance with the IS&C specification. The results of evaluation tell that this system is superior to other existing methods of the same kind such as transcribing, dictating, handwriting, typewriting and key selections. The most significant advantage of the system is that images and their interpretation are never separated. The first practical application to the teaching file and the teaching conference is contemplated in the Osaka University Hospital. This system is a complete digital system in terms of images, voices and demographic data, so that on-line transmission, off-line communication or filing to any database will be easily realized in a PACS environment. We are developing an integrated system of a speech recognizer connected to this digitized oral system.
Kamauu, Aaron W C; DuVall, Scott L; Wiggins, Richard H; Avrin, David E
2008-09-01
In the creation of interesting radiological cases in a digital teaching file, it is necessary to adjust the window and level settings of an image to effectively display the educational focus. The web-based applet described in this paper presents an effective solution for real-time window and level adjustments without leaving the picture archiving and communications system workstation. Optimized images are created, as user-defined parameters are passed between the applet and a servlet on the Health Insurance Portability and Accountability Act-compliant teaching file server.
Eng, J
1997-01-01
Java is a programming language that runs on a "virtual machine" built into World Wide Web (WWW)-browsing programs on multiple hardware platforms. Web pages were developed with Java to enable Web-browsing programs to overlay transparent graphics and text on displayed images so that the user could control the display of labels and annotations on the images, a key feature not available with standard Web pages. This feature was extended to include the presentation of normal radiologic anatomy. Java programming was also used to make Web browsers compatible with the Digital Imaging and Communications in Medicine (DICOM) file format. By enhancing the functionality of Web pages, Java technology should provide greater incentive for using a Web-based approach in the development of radiology teaching material.
A new approach to learning how to teach: medical students as instructional designers.
Novak, Sean H; Quinn, Molly; Canan, Timothy; Metten, Shaleen; Wisco, Jonathan J; Wimmers, Paul F; Uijtdehaage, Sebastian
2011-01-01
As students at the David Geffen School of Medicine at UCLA, the student authors were given the opportunity to develop their own creative projects which would be used to teach future medical students. They chose their own topics, planned and researched their projects, and then implemented the projects in interactive digital Adobe Flash files. In the first project they created interactive case-based radiology teaching files. In the second project they integrated photographic images into the existing illustrative anatomy files. Students in subsequent years have learned from these files on computers both at home and in the school's anatomy lab. The experience of creating the files served as an opportunity for hands-on learning for the student authors, both of the material and of the practice of teaching. In this paper they describe why they undertook these projects, what exactly they did, and the impact their creation had on them. The projects demonstrate that student-driven educational materials are both possible and beneficial. Furthermore, their experience has allowed them to conclude that faculty at other medical schools should consider providing students with opportunities to develop their own creative projects that contribute to the curriculum.
A cloud-based multimodality case file for mobile devices.
Balkman, Jason D; Loehfelm, Thomas W
2014-01-01
Recent improvements in Web and mobile technology, along with the widespread use of handheld devices in radiology education, provide unique opportunities for creating scalable, universally accessible, portable image-rich radiology case files. A cloud database and a Web-based application for radiologic images were developed to create a mobile case file with reasonable usability, download performance, and image quality for teaching purposes. A total of 75 radiology cases related to breast, thoracic, gastrointestinal, musculoskeletal, and neuroimaging subspecialties were included in the database. Breast imaging cases are the focus of this article, as they best demonstrate handheld display capabilities across a wide variety of modalities. This case subset also illustrates methods for adapting radiologic content to cloud platforms and mobile devices. Readers will gain practical knowledge about storage and retrieval of cloud-based imaging data, an awareness of techniques used to adapt scrollable and high-resolution imaging content for the Web, and an appreciation for optimizing images for handheld devices. The evaluation of this software demonstrates the feasibility of adapting images from most imaging modalities to mobile devices, even in cases of full-field digital mammograms, where high resolution is required to represent subtle pathologic features. The cloud platform allows cases to be added and modified in real time by using only a standard Web browser with no application-specific software. Challenges remain in developing efficient ways to generate, modify, and upload radiologic and supplementary teaching content to this cloud-based platform. Online supplemental material is available for this article. ©RSNA, 2014.
Rowe, Steven P; Siddiqui, Adeel; Bonekamp, David
2014-07-01
To create novel radiology key image software that is easy to use for novice users, incorporates elements adapted from social networking Web sites, facilitates resident and fellow education, and can serve as the engine for departmental sharing of interesting cases and follow-up studies. Using open-source programming languages and software, radiology key image software (the key image and case log application, KICLA) was developed. This system uses a lightweight interface with the institutional picture archiving and communications systems and enables the storage of key images, image series, and cine clips. It was designed to operate with minimal disruption to the radiologists' daily workflow. Many features of the user interface have been inspired by social networking Web sites, including image organization into private or public folders, flexible sharing with other users, and integration of departmental teaching files into the system. We also review the performance, usage, and acceptance of this novel system. KICLA was implemented at our institution and achieved widespread popularity among radiologists. A large number of key images have been transmitted to the system since it became available. After this early experience period, the most commonly encountered radiologic modalities are represented. A survey distributed to users revealed that most of the respondents found the system easy to use (89%) and fast at allowing them to record interesting cases (100%). Hundred percent of respondents also stated that they would recommend a system such as KICLA to their colleagues. The system described herein represents a significant upgrade to the Digital Imaging and Communications in Medicine teaching file paradigm with efforts made to maximize its ease of use and inclusion of characteristics inspired by social networking Web sites that allow the system additional functionality such as individual case logging. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.
Historic Methods for Capturing Magnetic Field Images
ERIC Educational Resources Information Center
Kwan, Alistair
2016-01-01
I investigated two late 19th-century methods for capturing magnetic field images from iron filings for historical insight into the pedagogy of hands-on physics education methods, and to flesh out teaching and learning practicalities tacit in the historical record. Both methods offer opportunities for close sensory engagement in data-collection…
Pereira, Andre; Atri, Mostafa; Rogalla, Patrik; Huynh, Thien; O'Malley, Martin E
2015-11-01
The value of a teaching case repository in radiology training programs is immense. The allocation of resources for putting one together is a complex issue, given the factors that have to be coordinated: hardware, software, infrastructure, administration, and ethics. Costs may be significant and cost-effective solutions are desirable. We chose Medical Imaging Resource Center (MIRC) to build our teaching file. It is offered by RSNA for free. For the hardware, we chose the Raspberry Pi, developed by the Raspberry Foundation: a small control board developed as a low cost computer for schools also used in alternative projects such as robotics and environmental data collection. Its performance and reliability as a file server were unknown to us. For the operational system, we chose Raspbian, a variant of Debian Linux, along with Apache (web server), MySql (database server) and PHP, which enhance the functionality of the server. A USB hub and an external hard drive completed the setup. Installation of software was smooth. The Raspberry Pi was able to handle very well the task of hosting the teaching file repository for our division. Uptime was logged at 100 %, and loading times were similar to other MIRC sites available online. We setup two servers (one for backup), each costing just below $200.00 including external storage and USB hub. It is feasible to run RSNA's MIRC off a low-cost control board (Raspberry Pi). Performance and reliability are comparable to full-size servers for the intended purpose of hosting a teaching file within an intranet environment.
1995 Joseph E. Whitley, MD, Award. A World Wide Web gateway to the radiologic learning file.
Channin, D S
1995-12-01
Computer networks in general, and the Internet specifically, are changing the way information is manipulated in the world at large and in radiology. The goal of this project was to develop a computer system in which images from the Radiologic Learning File, available previously only via a single-user laser disc, are made available over a generic, high-availability computer network to many potential users simultaneously. Using a networked workstation in our laboratory and freely available distributed hypertext software, we established a World Wide Web (WWW) information server for radiology. Images from the Radiologic Learning File are requested through the WWW client software, digitized from a single laser disc containing the entire teaching file and then transmitted over the network to the client. The text accompanying each image is incorporated into the transmitted document. The Radiologic Learning File is now on-line, and requests to view the cases result in the delivery of the text and images. Image digitization via a frame grabber takes 1/30th of a second. Conversion of the image to a standard computer graphic format takes 45-60 sec. Text and image transmission speed on a local area network varies between 200 and 400 kilobytes (KB) per second depending on the network load. We have made images from a laser disc of the Radiologic Learning File available through an Internet-based hypertext server. The images previously available through a single-user system located in a remote section of our department are now ubiquitously available throughout our department via the department's computer network. We have thus converted a single-user, limited functionality system into a multiuser, widely available resource.
Functional evaluation of telemedicine with super high definition images and B-ISDN.
Takeda, H; Matsumura, Y; Okada, T; Kuwata, S; Komori, M; Takahashi, T; Minatom, K; Hashimoto, T; Wada, M; Fujio, Y
1998-01-01
In order to determine whether a super high definition (SHD) image running at a series of 2048 resolution x 2048 line x 60 frame/sec was capable of telemedicine, we established a filing system for medical images and two experiments for transmission of high quality images were performed. All images of various types, produced from one case of ischemic heart disease were digitized and registered into the filing system. Images consisted of plain chest x-ray, electrocardiogram, ultrasound cardiogram, cardiac scintigram, coronary angiogram, left ventriculogram and so on. All images were animated and totaled a number of 243. We prepared a graphic user interface (GUI) for image retrieval based on the medical events and modalities. Twenty one cardiac specialists evaluated quality of the SHD images to be somewhat poor compared to the original pictures but sufficient for making diagnoses, and effective as a tool for teaching and case study purposes. The system capability of simultaneously displaying several animated images was especially deemed effective in grasping comprehension of diagnosis. Efficient input methods and creating capacity of filing all produced images are future issue. Using B-ISDN network, the SHD file was prefetched to the servers at Kyoto University Hospital and BBCC (Bradband ISDN Business chance & Culture Creation) laboratory as an telemedicine experiment. Simultaneous video conference system, the control of image retrieval and pointing function made the teleconference successful in terms of high quality of medical images, quick response time and interactive data exchange.
[Digital teaching archive. Concept, implementation, and experiences in a university setting].
Trumm, C; Dugas, M; Wirth, S; Treitl, M; Lucke, A; Küttner, B; Pander, E; Clevert, D-A; Glaser, C; Reiser, M
2005-08-01
Film-based teaching files require a substantial investment in human, logistic, and financial resources. The combination of computer and network technology facilitates the workflow integration of distributing radiologic teaching cases within an institution (intranet) or via the World Wide Web (Internet). A digital teaching file (DTF) should include the following basic functions: image import from different sources and of different formats, editing of imported images, uniform case classification, quality control (peer review), a controlled access of different user groups (in-house and external), and an efficient retrieval strategy. The portable network graphics image format (PNG) is especially suitable for DTFs because of several features: pixel support, 2D-interlacing, gamma correction, and lossless compression. The American College of Radiology (ACR) "Index for Radiological Diagnoses" is hierarchically organized and thus an ideal classification system for a DTF. Computer-based training (CBT) in radiology is described in numerous publications, from supplementing traditional learning methods to certified education via the Internet. Attractiveness of a CBT application can be increased by integration of graphical and interactive elements but makes workflow integration of daily case input more difficult. Our DTF was built with established Internet instruments and integrated into a heterogeneous PACS/RIS environment. It facilitates a quick transfer (DICOM_Send) of selected images at the time of interpretation to the DTF and access to the DTF application at any time anywhere within the university hospital intranet employing a standard web browser. A DTF is a small but important building block in an institutional strategy of knowledge management.
The virtual microscopy database-sharing digital microscope images for research and education.
Lee, Lisa M J; Goldman, Haviva M; Hortsch, Michael
2018-02-14
Over the last 20 years, virtual microscopy has become the predominant modus of teaching the structural organization of cells, tissues, and organs, replacing the use of optical microscopes and glass slides in a traditional histology or pathology laboratory setting. Although virtual microscopy image files can easily be duplicated, creating them requires not only quality histological glass slides but also an expensive whole slide microscopic scanner and massive data storage devices. These resources are not available to all educators and researchers, especially at new institutions in developing countries. This leaves many schools without access to virtual microscopy resources. The Virtual Microscopy Database (VMD) is a new resource established to address this problem. It is a virtual image file-sharing website that allows researchers and educators easy access to a large repository of virtual histology and pathology image files. With the support from the American Association of Anatomists (Bethesda, MD) and MBF Bioscience Inc. (Williston, VT), registration and use of the VMD are currently free of charge. However, the VMD site is restricted to faculty and staff of research and educational institutions. Virtual Microscopy Database users can upload their own collection of virtual slide files, as well as view and download image files for their own non-profit educational and research purposes that have been deposited by other VMD clients. Anat Sci Educ. © 2018 American Association of Anatomists. © 2018 American Association of Anatomists.
Development of a user-centered radiology teaching file system
NASA Astrophysics Data System (ADS)
dos Santos, Marcelo; Fujino, Asa
2011-03-01
Learning radiology requires systematic and comprehensive study of a large knowledge base of medical images. In this work is presented the development of a digital radiology teaching file system. The proposed system has been created in order to offer a set of customized services regarding to users' contexts and their informational needs. This has been done by means of an electronic infrastructure that provides easy and integrated access to all relevant patient data at the time of image interpretation, so that radiologists and researchers can examine all available data to reach well-informed conclusions, while protecting patient data privacy and security. The system is presented such as an environment which implements a distributed clinical database, including medical images, authoring tools, repository for multimedia documents, and also a peer-reviewed model which assures dataset quality. The current implementation has shown that creating clinical data repositories on networked computer environments points to be a good solution in terms of providing means to review information management practices in electronic environments and to create customized and contextbased tools for users connected to the system throughout electronic interfaces.
Construction of the radiation oncology teaching files system for charged particle radiotherapy.
Masami, Mukai; Yutaka, Ando; Yasuo, Okuda; Naoto, Takahashi; Yoshihisa, Yoda; Hiroshi, Tsuji; Tadashi, Kamada
2013-01-01
Our hospital started the charged particle therapy since 1996. New institutions for charged particle therapy are planned in the world. Our hospital are accepting many visitors from those newly planned medical institutions and having many opportunities to provide with the training to them. Based upon our experiences, we have developed the radiation oncology teaching files system for charged particle therapy. We adopted the PowerPoint of Microsoft as a basic framework of our teaching files system. By using our export function of the viewer any physician can create teaching files easily and effectively. Now our teaching file system has 33 cases for clinical and physics contents. We expect that we can improve the safety and accuracy of charged particle therapy by using our teaching files system substantially.
Khushi, Matloob; Edwards, Georgina; de Marcos, Diego Alonso; Carpenter, Jane E; Graham, J Dinny; Clarke, Christine L
2013-02-12
Virtual microscopy includes digitisation of histology slides and the use of computer technologies for complex investigation of diseases such as cancer. However, automated image analysis, or website publishing of such digital images, is hampered by their large file sizes. We have developed two Java based open source tools: Snapshot Creator and NDPI-Splitter. Snapshot Creator converts a portion of a large digital slide into a desired quality JPEG image. The image is linked to the patient's clinical and treatment information in a customised open source cancer data management software (Caisis) in use at the Australian Breast Cancer Tissue Bank (ABCTB) and then published on the ABCTB website (http://www.abctb.org.au) using Deep Zoom open source technology. Using the ABCTB online search engine, digital images can be searched by defining various criteria such as cancer type, or biomarkers expressed. NDPI-Splitter splits a large image file into smaller sections of TIFF images so that they can be easily analysed by image analysis software such as Metamorph or Matlab. NDPI-Splitter also has the capacity to filter out empty images. Snapshot Creator and NDPI-Splitter are novel open source Java tools. They convert digital slides into files of smaller size for further processing. In conjunction with other open source tools such as Deep Zoom and Caisis, this suite of tools is used for the management and archiving of digital microscopy images, enabling digitised images to be explored and zoomed online. Our online image repository also has the capacity to be used as a teaching resource. These tools also enable large files to be sectioned for image analysis. The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/5330903258483934.
Katzman, G L
2001-03-01
The goal of the project was to create a method by which an in-house digital teaching file could be constructed that was simple, inexpensive, independent of hypertext markup language (HTML) restrictions, and appears identical on multiple platforms. To accomplish this, Microsoft PowerPoint and Adobe Acrobat were used in succession to assemble digital teaching files in the Acrobat portable document file format. They were then verified to appear identically on computers running Windows, Macintosh Operating Systems (OS), and the Silicon Graphics Unix-based OS as either a free-standing file using Acrobat Reader software or from within a browser window using the Acrobat browser plug-in. This latter display method yields a file viewed through a browser window, yet remains independent of underlying HTML restrictions, which may confer an advantage over simple HTML teaching file construction. Thus, a hybrid of HTML-distributed Adobe Acrobat generated WWW documents may be a viable alternative for digital teaching file construction and distribution.
A step-by-step solution for embedding user-controlled cines into educational Web pages.
Cornfeld, Daniel
2008-03-01
The objective of this article is to introduce a simple method for embedding user-controlled cines into a Web page using a simple JavaScript. Step-by-step instructions are included and the source code is made available. This technique allows the creation of portable Web pages that allow the user to scroll through cases as if seated at a PACS workstation. A simple JavaScript allows scrollable image stacks to be included on Web pages. With this technique, you can quickly and easily incorporate entire stacks of CT or MR images into online teaching files. This technique has the potential for use in case presentations, online didactics, teaching archives, and resident testing.
The Full Monty: Locating Resources, Creating, and Presenting a Web Enhanced History Course.
ERIC Educational Resources Information Center
Bazillion, Richard J.; Braun, Connie L.
2001-01-01
Discusses how to develop a history course using the World Wide Web; course development software; full text digitized articles, electronic books, primary documents, images, and audio files; and computer equipment such as LCD projectors and interactive whiteboards. Addresses the importance of support for faculty using technology in teaching. (PAL)
Implementing desktop image access of GI images
NASA Astrophysics Data System (ADS)
Grevera, George J.; Feingold, Eric R.; Horii, Steven C.; Laufer, Igor
1996-05-01
In this paper we present a specific example of the current state-of-the-art in desktop image access in the GI section of the Department of Radiology at the Hospital of the University of Pennsylvania. We describe a system which allows physicians to view and manipulate images from a Philips digital fluoroscopy system at the workstations in their offices. Typically they manipulate and view these images on their desktop Macs and then submit the results for slide making or save the images in digital teaching files. In addition to a discussion of the current state-of-the-art here at HUP, we also discuss some future directions that we are pursuing.
2013-01-01
Background Virtual microscopy includes digitisation of histology slides and the use of computer technologies for complex investigation of diseases such as cancer. However, automated image analysis, or website publishing of such digital images, is hampered by their large file sizes. Results We have developed two Java based open source tools: Snapshot Creator and NDPI-Splitter. Snapshot Creator converts a portion of a large digital slide into a desired quality JPEG image. The image is linked to the patient’s clinical and treatment information in a customised open source cancer data management software (Caisis) in use at the Australian Breast Cancer Tissue Bank (ABCTB) and then published on the ABCTB website (http://www.abctb.org.au) using Deep Zoom open source technology. Using the ABCTB online search engine, digital images can be searched by defining various criteria such as cancer type, or biomarkers expressed. NDPI-Splitter splits a large image file into smaller sections of TIFF images so that they can be easily analysed by image analysis software such as Metamorph or Matlab. NDPI-Splitter also has the capacity to filter out empty images. Conclusions Snapshot Creator and NDPI-Splitter are novel open source Java tools. They convert digital slides into files of smaller size for further processing. In conjunction with other open source tools such as Deep Zoom and Caisis, this suite of tools is used for the management and archiving of digital microscopy images, enabling digitised images to be explored and zoomed online. Our online image repository also has the capacity to be used as a teaching resource. These tools also enable large files to be sectioned for image analysis. Virtual Slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/5330903258483934 PMID:23402499
ERIC Educational Resources Information Center
National Center for Education Statistics (ED), Washington, DC.
The National Longitudinal Survey of the High School Class of 1972 (NLS-72) Teaching Supplement Data File (TSDF) is presented. Data for the machine-readable data file (MDRF) were collected via a mail questionnaire that was sent to all respondents (N=1,517) to the fifth follow-up survey who indicated that they had a teaching background or training…
Informatics in radiology (infoRAD): HTML and Web site design for the radiologist: a primer.
Ryan, Anthony G; Louis, Luck J; Yee, William C
2005-01-01
A Web site has enormous potential as a medium for the radiologist to store, present, and share information in the form of text, images, and video clips. With a modest amount of tutoring and effort, designing a site can be as painless as preparing a Microsoft PowerPoint presentation. The site can then be used as a hub for the development of further offshoots (eg, Web-based tutorials, storage for a teaching library, publication of information about one's practice, and information gathering from a wide variety of sources). By learning the basics of hypertext markup language (HTML), the reader will be able to produce a simple and effective Web page that permits display of text, images, and multimedia files. The process of constructing a Web page can be divided into five steps: (a) creating a basic template with formatted text, (b) adding color, (c) importing images and multimedia files, (d) creating hyperlinks, and (e) uploading one's page to the Internet. This Web page may be used as the basis for a Web-based tutorial comprising text documents and image files already in one's possession. Finally, there are many commercially available packages for Web page design that require no knowledge of HTML.
Expanding the PACS archive to support clinical review, research, and education missions
NASA Astrophysics Data System (ADS)
Honeyman-Buck, Janice C.; Frost, Meryll M.; Drane, Walter E.
1999-07-01
Designing an image archive and retrieval system that supports multiple users with many different requirements and patterns of use without compromising the performance and functionality required by diagnostic radiology is an intellectual and technical challenge. A diagnostic archive, optimized for performance when retrieving diagnostic images for radiologists needed to be expanded to support a growing clinical review network, the University of Florida Brain Institute's demands for neuro-imaging, Biomedical Engineering's imaging sciences, and an electronic teaching file. Each of the groups presented a different set of problems for the designers of the system. In addition, the radiologists did not want to see nay loss of performance as new users were added.
Web Tools for Distributed Clinical Case Conferencing
Lober, WB; Li, H; Trigg, LJ; Stewart, BK; Chou, D
2001-01-01
We have developed an information system to support distributed clinical case conferences held via video conferencing. The system has been designed by studying physicians of several specialties presenting hematology-oncology patients at Tumor Board. However, the principles of clinical case presentation are similar across many medical specialties, and we believe our approach has general applicability for presenting image and other clinical information, and organizing it for subsequent re-use in teaching files.
Strategies for Keeping Papers Organized.
ERIC Educational Resources Information Center
Dwyer, Edward J.
1989-01-01
The amount of paperwork in teaching often seems overwhelming. This being the case, organization is essential for effective teaching. Several ideas for dealing with paper flow are useful. Box file folders or durable plastic file cases, plus an ample supply of file folders, are excellent for storing papers. Papers used in a particular class can be…
Radiology Teacher: a free, Internet-based radiology teaching file server.
Talanow, Roland
2009-12-01
Teaching files are an essential ingredient in residency education. The online program Radiology Teacher was developed to allow the creation of interactive and customized teaching files in real time. Online access makes it available anytime and anywhere, and it is free of charge, user tailored, and easy to use. No programming skills, additional plug-ins, or installations are needed, allowing its use even on protected intranets. Special effects for enhancing the learning experience as well as the linking and the source code are created automatically by the program. It may be used in different modes by individuals and institutions to share cases from multiple authors in a single database. Radiology Teacher is an easy-to-use automatic teaching file program that may enhance users' learning experiences by offering different modes of user-defined presentations.
Extracting the Data From the LCM vk4 Formatted Output File
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wendelberger, James G.
These are slides about extracting the data from the LCM vk4 formatted output file. The following is covered: vk4 file produced by Keyence VK Software, custom analysis, no off the shelf way to read the file, reading the binary data in a vk4 file, various offsets in decimal lines, finding the height image data, directly in MATLAB, binary output beginning of height image data, color image information, color image binary data, color image decimal and binary data, MATLAB code to read vk4 file (choose a file, read the file, compute offsets, read optical image, laser optical image, read and computemore » laser intensity image, read height image, timing, display height image, display laser intensity image, display RGB laser optical images, display RGB optical images, display beginning data and save images to workspace, gamma correction subroutine), reading intensity form the vk4 file, linear in the low range, linear in the high range, gamma correction for vk4 files, computing the gamma intensity correction, observations.« less
Alrahabi, Mothanna
2015-01-01
We evaluated the use of NiTi rotary and stainless steel endodontic instruments for canal shaping by undergraduate students. We also assessed the quality of root canal preparation as well as the occurrence of iatrogenic events during instrumentation. In total, 30 third-year dental students attending Taibah University Dental College prepared 180 simulated canals in resin blocks with NiTi rotary instruments and stainless steel hand files. Superimposed images were prepared to measure the removal of material at different levels from apical termination using the GSA image analysis software. Preparation time, procedural accidents, and canal shape after preparation were analyzed using χ 2 and t-tests. The statistical significance level was set at P < 0.05. There were significant differences in preparation time between NiTi instruments and stainless steel files; the former was associated with shorter preparation time, less ledge formation (1.1% vs. 14.4%), and greater instrument fracture (5.56% vs. 1.1%). These results indicate that NiTi rotary instruments result in better canal geometry and cause less canal transportation. Manual instrumentation using stainless steel files is safer than rotary instrumentation for inexperienced students. Intensive preclinical training is a prerequisite for using NiTi rotary instruments. These results prompted us to reconsider theoretical and practical coursework when teaching endodontics.
Teaching "Filing Rules"--Via Computer-Aided Instruction.
ERIC Educational Resources Information Center
Agneberg, Craig
A computer software package has been developed to teach and test students on the Rules for Alphabetical Filing of the Association of Records Managers and Administrators (ARMA). The following computer assisted instruction principles were used in developing the program: gaining attention, stating objectives, providing direction, reviewing…
Teaching Reprint File Management: Basic Principles and Software Programs.
ERIC Educational Resources Information Center
Wood, Elizabeth H.
1989-01-01
Describes a workshop for teaching library users how to manage reprint files which was developed at the University of Southern California Norris Medical Library. Software programs designed for this purpose are suggested, and a sidebar lists software features to consider. (eight references) (MES)
Wahlgren, Carl-Fredrik; Edelbring, Samuel; Fors, Uno; Hindbeck, Hans; Ståhle, Mona
2006-01-01
Background Most of the many computer resources used in clinical teaching of dermatology and venereology for medical undergraduates are information-oriented and focus mostly on finding a "correct" multiple-choice alternative or free-text answer. We wanted to create an interactive computer program, which facilitates not only factual recall but also clinical reasoning. Methods Through continuous interaction with students, a new computerised interactive case simulation system, NUDOV, was developed. It is based on authentic cases and contains images of real patients, actors and healthcare providers. The student selects a patient and proposes questions for medical history, examines the skin, and suggests investigations, diagnosis, differential diagnoses and further management. Feedback is given by comparing the user's own suggestions with those of a specialist. In addition, a log file of the student's actions is recorded. The program includes a large number of images, video clips and Internet links. It was evaluated with a student questionnaire and by randomising medical students to conventional teaching (n = 85) or conventional teaching plus NUDOV (n = 31) and comparing the results of the two groups in a final written examination. Results The questionnaire showed that 90% of the NUDOV students stated that the program facilitated their learning to a large/very large extent, and 71% reported that extensive working with authentic computerised cases made it easier to understand and learn about diseases and their management. The layout, user-friendliness and feedback concept were judged as good/very good by 87%, 97%, and 100%, respectively. Log files revealed that the students, in general, worked with each case for 60–90 min. However, the intervention group did not score significantly better than the control group in the written examination. Conclusion We created a computerised case simulation program allowing students to manage patients in a non-linear format supporting the clinical reasoning process. The student gets feedback through comparison with a specialist, eliminating the need for external scoring or correction. The model also permits discussion of case processing, since all transactions are stored in a log file. The program was highly appreciated by the students, but did not significantly improve their performance in the written final examination. PMID:16907972
Innovation in the imaging perianal fistula: a step towards personalised medicine
Sahnan, Kapil; Adegbola, Samuel O.; Tozer, Philip J.; Patel, Uday; Ilangovan, Rajpandian; Warusavitarne, Janindra; Faiz, Omar D.; Hart, Ailsa L.; Phillips, Robin K. S.; Lung, Phillip F. C.
2018-01-01
Background: Perianal fistula is a topic both hard to understand and to teach. The key to understanding the treatment options and the likely success is deciphering the exact morphology of the tract(s) and the amount of sphincter involved. Our aim was to explore alternative platforms better to understand complex perianal fistulas through three-dimensional (3D) imaging and reconstruction. Methods: Digital imaging and communications in medicine images of spectral attenuated inversion recovery magnetic resonance imaging (MRI) sequences were imported onto validated open-source segmentation software. A specialist consultant gastrointestinal radiologist performed segmentation of the fistula, internal and external sphincter. Segmented files were exported as stereolithography files. Cura (Ultimaker Cura 3.0.4) was used to prepare the files for printing on an Ultimaker 3 Extended 3D printer. Animations were created in collaboration with Touch Surgery™. Results: Three examples of 3D printed models demonstrating complex perianal fistula were created. The anatomical components are displayed in different colours: red: fistula tract; green: external anal sphincter and levator plate; blue: internal anal sphincter and rectum. One of the models was created to be split in half, to display the internal opening and allow complexity in the intersphincteric space to better evaluated. An animation of MRI fistulography of a trans-sphincteric fistula tract with a cephalad extension in the intersphincteric space was also created. Conclusion: MRI is the reference standard for assessment of perianal fistula, defining anatomy and guiding surgery. However, communication of findings between radiologist and surgeon remains challenging. Feasibility of 3D reconstructions of complex perianal fistula is realized, with the potential to improve surgical planning, communication with patients, and augment training. PMID:29854001
Distributed file management for remote clinical image-viewing stations
NASA Astrophysics Data System (ADS)
Ligier, Yves; Ratib, Osman M.; Girard, Christian; Logean, Marianne; Trayser, Gerhard
1996-05-01
The Geneva PACS is based on a distributed architecture, with different archive servers used to store all the image files produced by digital imaging modalities. Images can then be visualized on different display stations with the Osiris software. Image visualization require to have the image file physically present on the local station. Thus, images must be transferred from archive servers to local display stations in an acceptable way, which means fast and user friendly where the notion of file must be hidden to users. The transfer of image files is done according to different schemes including prefetching and direct image selection. Prefetching allows the retrieval of previous studies of a patient in advance. A direct image selection is also provided in order to retrieve images on request. When images are transferred locally on the display station, they are stored in Papyrus files, each file containing a set of images. File names are used by the Osiris viewing software to open image sequences. But file names alone are not explicit enough to properly describe the content of the file. A specific utility has been developed to present a list of patients, and for each patient a list of exams which can be selected and automatically displayed. The system has been successfully tested in different clinical environments. It will be soon extended on a hospital wide basis.
Impact of ultrasound video transfer on the practice of ultrasound
NASA Astrophysics Data System (ADS)
Duerinckx, Andre J.; Hayrapetian, Alek S.; Grant, Edward G.; Valentino, Daniel J.; Rahbar, Darius; Kiszonas, Mike; Franco, Ricky; Melany, Michelle; Narin, Sherelle L.; Ragavendra, Nagesh
1996-05-01
Sonography can be highly dependent on real-time imaging and as such is highly physician intensive. Such situations arise mostly during complicated ultrasound radiology studies or echocardiology examinations. Under those circumstances it would be of benefit to transmit real-time images beyond the immediate area of the ultrasound laboratory when a physician is not on location. We undertook this study to determine if both static and dynamic image transfer to remote locations might be accomplished using an ultrafast ATM network and PACS. Image management of the local image files was performed by a commercial PACS from AGFA corporation. The local network was Ethernet based, and the global network was based on Asynchronous Transfer Mode (ATM, rates up to 100 Mbits/sec). Real-time image transfer involved two teaching hospitals, one of which had 2 separate ultrasound facilities. Radiologists consulted with technologists via telephone while the examinations were being performed. The applications of ATM network providing real time video for ultrasound imaging in a clinical environment and its potential impact on health delivery and clinical teaching. This technology increased technologist and physician productivity due to the elimination of commute time for physicians and waiting time for technologists and patients. Physician confidence in diagnosis increased compared to reviewing static images alone. This system provided instant access for radiologists to real-time scans from remote sites. Image quality and frame rate were equivalent to the original. The system increased productivity by allowing physicians to monitor studies at multiple sites simultaneously.
Stern, E J; Westenberg, L
1995-05-01
Desktop computer hardware and software provide many new and accessible avenues for increased academic productivity, but some activities may have legal implications. The advent of technologies such as scanners, the ever-increasing number of electronic bulletin boards, and the development of the "information superhighway" affect the concept of copyright and require authors and publishers to reconsider their legal rights and obligations when they create or publish new works or modify existing ones. For example, with desktop scanners, almost any image, published or otherwise, can be copied, enhanced, and manipulated. Moreover, many radiologists have access to copyrighted digital radiologic teaching file images, such as those from the University of Iowa or the University of Washington, which are available (and "downloadable") on the Internet. Because "downloading" (or "uploading") a document or image is essentially making a copy of that document or image, copyright laws and the rights that they afford authors are involved.
77 FR 59692 - 2014 Diversity Immigrant Visa Program
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-28
... the E-DV system. The entry will not be accepted and must be resubmitted. Group or family photographs... must be in the Joint Photographic Experts Group (JPEG) format. Image File Size: The maximum file size...). Image File Format: The image must be in the Joint Photographic Experts Group (JPEG) format. Image File...
Digital processing of radiographic images from PACS to publishing.
Christian, M E; Davidson, H C; Wiggins, R H; Berges, G; Cannon, G; Jackson, G; Chapman, B; Harnsberger, H R
2001-03-01
Several studies have addressed the implications of filmless radiologic imaging on telemedicine, diagnostic ability, and electronic teaching files. However, many publishers still require authors to submit hard-copy images for publication of articles and textbooks. This study compares the quality digital images directly exported from picture archive and communications systems (PACS) to images digitized from radiographic film. The authors evaluated the quality of publication-grade glossy photographs produced from digital radiographic images using 3 different methods: (1) film images digitized using a desktop scanner and then printed, (2) digital images obtained directly from PACS then printed, and (3) digital images obtained from PACS and processed to improve sharpness prior to printing. Twenty images were printed using each of the 3 different methods and rated for quality by 7 radiologists. The results were analyzed for statistically significant differences among the image sets. Subjective evaluations of the filmless images found them to be of equal or better quality than the digitized images. Direct electronic transfer of PACS images reduces the number of steps involved in creating publication-quality images as well as providing the means to produce high-quality radiographic images in a digital environment.
Digital camera with apparatus for authentication of images produced from an image file
NASA Technical Reports Server (NTRS)
Friedman, Gary L. (Inventor)
1993-01-01
A digital camera equipped with a processor for authentication of images produced from an image file taken by the digital camera is provided. The digital camera processor has embedded therein a private key unique to it, and the camera housing has a public key that is so uniquely based upon the private key that digital data encrypted with the private key by the processor may be decrypted using the public key. The digital camera processor comprises means for calculating a hash of the image file using a predetermined algorithm, and second means for encrypting the image hash with the private key, thereby producing a digital signature. The image file and the digital signature are stored in suitable recording means so they will be available together. Apparatus for authenticating at any time the image file as being free of any alteration uses the public key for decrypting the digital signature, thereby deriving a secure image hash identical to the image hash produced by the digital camera and used to produce the digital signature. The apparatus calculates from the image file an image hash using the same algorithm as before. By comparing this last image hash with the secure image hash, authenticity of the image file is determined if they match, since even one bit change in the image hash will cause the image hash to be totally different from the secure hash.
How to Make a Virtual Landscape with Outcrops for Use in Geoscience Teaching
NASA Astrophysics Data System (ADS)
Houghton, J.; Gordon, C.; Craven, B.; Robinson, A.; Lloyd, G. E. E.; Morgan, D. J.
2016-12-01
We are using screen-based virtual reality landscapes to augment the teaching of basic geological field skills and to enhance 3D visualisation skills. Here we focus on the processes of creating these landscapes, both imagined and real, in the Unity 3D game engine. The virtual landscapes are terrains with embedded data for mapping exercises, or draped geological maps for understanding the 3D interaction of the geology with the topography. The nature of the landscapes built depends on the learning outcomes of the intended teaching exercise. For example, a simple model of two hills and a valley over which to drape a series of different geological maps can be used to enhance the understanding of the 3D interaction of the geology with the topography. A more complex topography reflecting the underlying geology can be used for geological mapping exercises. The process starts with a contour image or DEM, which needs to be converted into RAW files to be imported into Unity. Within Unity itself, there are a series of steps needed to create a world around the terrain (the setting of cameras, lighting, skyboxes etc) before the terrain can be painted with vegetation and populated with assets or before a splatmap of the geology can be added. We discuss how additional features such as a GPS unit or compass can be included. We are also working to create landscapes based on real localities, both in response to the demand for greater realism and to support students unable to access the field due to health or mobility issues. This includes adding 3D photogrammetric images of outcrops into the worlds. This process uses the open source/freeware tools VisualSFM and MeshLab to create files suitable to be imported into Unity. This project is a collaboration between the University of Leeds and Leeds College of Art, UK, and all our virtual landscapes are freely available online at www.see.leeds.ac.uk/virtual-landscapes/.
Digital Camera with Apparatus for Authentication of Images Produced from an Image File
NASA Technical Reports Server (NTRS)
Friedman, Gary L. (Inventor)
1996-01-01
A digital camera equipped with a processor for authentication of images produced from an image file taken by the digital camera is provided. The digital camera processor has embedded therein a private key unique to it, and the camera housing has a public key that is so uniquely related to the private key that digital data encrypted with the private key may be decrypted using the public key. The digital camera processor comprises means for calculating a hash of the image file using a predetermined algorithm, and second means for encrypting the image hash with the private key, thereby producing a digital signature. The image file and the digital signature are stored in suitable recording means so they will be available together. Apparatus for authenticating the image file as being free of any alteration uses the public key for decrypting the digital signature, thereby deriving a secure image hash identical to the image hash produced by the digital camera and used to produce the digital signature. The authenticating apparatus calculates from the image file an image hash using the same algorithm as before. By comparing this last image hash with the secure image hash, authenticity of the image file is determined if they match. Other techniques to address time-honored methods of deception, such as attaching false captions or inducing forced perspectives, are included.
Growth plate injury at the base of the coracoid: MRI features.
Alaia, Erin FitzGerald; Rosenberg, Zehava Sadka; Rossi, Ignacio; Zember, Jonathan; Roedl, Johannes B; Pinkney, Lynne; Steinbach, Lynne S
2017-11-01
To assess the MRI features of growth plate injury at the base of the coracoid process. Subjects were identified through retrospective search of our department imaging database and teaching files and the teaching files of two outside academic institutions. The coracoid base growth plate was examined with attention to widening, irregularity, abnormal signal intensity of the growth plate, and the presence of adjacent soft tissue edema. The apposing coracoid and scapular bony surfaces were examined for signal intensity and morphology. Shoulder MRIs in eight patients with coracoid base growth plate disturbances were retrospectively reviewed (7 males, 1 female, mean age 15 years). Growth plate injury manifested as widening, irregularity and increased signal, apposing bony marrow edema and hypertrophy, and surrounding soft tissue edema. Five subjects were athletes (football, archery, basketball, swimming, rugby), two had a history of neuromuscular disorders, and one subject presented after a fall. Clinical indications included: rule out labral tear (n = 3), rule out rotator cuff tear or fracture after fall (n = 1), nonspecific pain (n = 1), shoulder subluxation, rule out glenoid pathology (n = 1, patient with underlying neuromuscular disorder), muscular dystrophy with shoulder pain (n = 1), and impingement (n = 1). Coracoid growth plate injury was not suspected clinically in any of the patients. Awareness of the imaging appearance of coracoid base growth plate injury can aid in a more accurate diagnosis of shoulder MRI studies in young pediatric athletes. While uncommon, coracoid growth plate injury should be considered when assessing children with shoulder symptomatology.
Cosmic sculpture: a new way to visualise the cosmic microwave background
NASA Astrophysics Data System (ADS)
Clements, D. L.; Sato, S.; Portela Fonseca, A.
2017-01-01
3D printing presents an attractive alternative to visual representation of physical datasets such as astronomical images that can be used for research, outreach or teaching purposes, and is especially relevant to people with a visual disability. We here report the use of 3D printing technology to produce a representation of the all-sky cosmic microwave background (CMB) intensity anisotropy maps produced by the Planck mission. The success of this work in representing key features of the CMB is discussed as is the potential of this approach for representing other astrophysical data sets. 3D printing such datasets represents a highly complementary approach to the usual 2D projections used in teaching and outreach work, and can also form the basis of undergraduate projects. The CAD files used to produce the models discussed in this paper are made available.
Image Size Variation Influence on Corrupted and Non-viewable BMP Image
NASA Astrophysics Data System (ADS)
Azmi, Tengku Norsuhaila T.; Azma Abdullah, Nurul; Rahman, Nurul Hidayah Ab; Hamid, Isredza Rahmi A.; Chai Wen, Chuah
2017-08-01
Image is one of the evidence component seek in digital forensics. Joint Photographic Experts Group (JPEG) format is most popular used in the Internet because JPEG files are very lossy and easy to compress that can speed up Internet transmitting processes. However, corrupted JPEG images are hard to recover due to the complexities of determining corruption point. Nowadays Bitmap (BMP) images are preferred in image processing compared to another formats because BMP image contain all the image information in a simple format. Therefore, in order to investigate the corruption point in JPEG, the file is required to be converted into BMP format. Nevertheless, there are many things that can influence the corrupting of BMP image such as the changes of image size that make the file non-viewable. In this paper, the experiment indicates that the size of BMP file influences the changes in the image itself through three conditions, deleting, replacing and insertion. From the experiment, we learnt by correcting the file size, it can able to produce a viewable file though partially. Then, it can be investigated further to identify the corruption point.
Representation of thermal infrared imaging data in the DICOM using XML configuration files.
Ruminski, Jacek
2007-01-01
The DICOM standard has become a widely accepted and implemented format for the exchange and storage of medical imaging data. Different imaging modalities are supported however there is not a dedicated solution for thermal infrared imaging in medicine. In this article we propose new ideas and improvements to final proposal of the new DICOM Thermal Infrared Imaging structures and services. Additionally, we designed, implemented and tested software packages for universal conversion of existing thermal imaging files to the DICOM format using XML configuration files. The proposed solution works fast and requires minimal number of user interactions. The XML configuration file enables to compose a set of attributes for any source file format of thermal imaging camera.
[Whole slide imaging technology: from digitization to online applications].
Ameisen, David; Le Naour, Gilles; Daniel, Christel
2012-11-01
As e-health becomes essential to modern care, whole slide images (virtual slides) are now an important clinical, teaching and research tool in pathology. Virtual microscopy consists of digitizing a glass slide by acquiring hundreds of tiles of regions of interest at different zoom levels and assembling them into a structured file. This gigapixel image can then be remotely viewed over a terminal, exactly the way pathologists use a microscope. In this article, we will first describe the key elements of this technology, from the acquisition, using a scanner or a motorized microscope, to the broadcasting of virtual slides through a local or distant viewer over an intranet or Internet connection. As virtual slides are now commonly used in virtual classrooms, clinical data and research databases, we will highlight the main issues regarding its uses in modern pathology. Emphasis will be made on quality assurance policies, standardization and scaling. © 2012 médecine/sciences – Inserm / SRMS.
The use of digital images in pathology.
Furness, P N
1997-11-01
Digital images are routinely used by the publishing industry, but most diagnostic pathologists are unfamiliar with the technology and its possibilities. This review aims to explain the basic principles of digital image acquisition, storage, manipulation and use, and the possibilities provided not only in research, but also in teaching and in routine diagnostic pathology. Images of natural objects are usually expressed digitally as 'bitmaps'--rectilinear arrays of small dots. The size of each dot can vary, but so can its information content in terms, for example, of colour, greyscale or opacity. Various file formats and compression algorithms are available. Video cameras connected to microscopes are familiar to most pathologists; video images can be converted directly to a digital form by a suitably equipped computer. Digital cameras and scanners are alternative acquisition tools of relevance to pathologists. Once acquired, a digital image can easily be subjected to the digital equivalent of any conventional darkroom manipulation and modern software allows much more flexibility, to such an extent that a new tool for scientific fraud has been created. For research, image enhancement and analysis is an increasingly powerful and affordable tool. Morphometric measurements are, after many predictions, at last beginning to be part of the toolkit of the diagnostic pathologist. In teaching, the potential to create dramatic yet informative presentations is demonstrated daily by the publishing industry; such methods are readily applicable to the classroom. The combination of digital images and the Internet raises many possibilities; for example, instead of seeking one expert diagnostic opinion, one could simultaneously seek the opinion of many, all around the globe. It is inevitable that in the coming years the use of digital images will spread from the laboratory to the medical curriculum and to the whole of diagnostic pathology.
Soft tissue rapid prototyping in neurosurgery.
Vloeberghs, M; Hatfield, F; Daemi, F; Dickens, P
1998-01-01
As part of our research into the fluid hydrodynamics of the human ventricular system, a fused deposition model of the human ventricular system was made using magnetic resonance imaging (MRI) data. This article describes the manufacturing of a positive cast of the ventricles as a first step in the construction of a hollow model. After decryption of the original MRI file (ACR-Nema format), the MRI slices were reassembled semiautomatically and a rapid prototyping station produced a resin model. Because of its ease and speed, this method harbors great potential for teaching purposes, research, and preoperative planning in complex three-dimensional soft tissue targets.
Nakamura, R; Sasaki, M; Oikawa, H; Harada, S; Tamakawa, Y
2000-03-01
To use an intranet technique to develop an information system that simultaneously supports both diagnostic reports and radiotherapy planning images. Using a file server as the gateway a radiation oncology LAN was connected to an already operative RIS LAN. Dose-distribution images were saved in tagged-image-file format by way of a screen dump to the file server. X-ray simulator images and portal images were saved in encapsulated postscript format in the file server and automatically converted to portable document format. The files on the file server were automatically registered to the Web server by the search engine and were available for searching and browsing using the Web browser. It took less than a minute to register planning images. For clients, searching and browsing the file took less than 3 seconds. Over 150,000 reports and 4,000 images from a six-month period were accessible. Because the intranet technique was used, construction and maintenance was completed without specialty. Prompt access to essential information about radiotherapy has been made possible by this system. It promotes public access to radiotherapy planning that may improve the quality of treatment.
40 CFR 264.71 - Use of manifest system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... revising paragraph (a)(2), and by adding paragraphs (f), (g), (h), (i), (j), and (k) to read as follows... image file of Page 1 of the manifest, or both a data string file and the image file corresponding to Page 1 of the manifest. Any data or image files transmitted to EPA under this paragraph must be...
Web-based radiology: a future to be created.
Canadè, Adolfo; Palladino, Francesco; Pitzalis, Gianluca; Campioni, Paolo; Marano, Pasquale
2003-01-01
The impact of Internet on Medicine and Surgery is certainly remarkable, however the influence it had on Diagnostic Imaging was even stronger. The standardization of digital images acquired by the different medical imaging equipment has further facilitated the diffusion, transmission and communication in radiology within hospitals as well as on WEB. Radiology departments are bound to become "filmless" and with the present "tablet PC" radiological images will be directly transferred to the patient's bed in the relative electronic patient report. For radiology, interactive education could be envisaged with a tutor who guides the student(s) through the network. The Internet is an inexhaustible source of radiologic educational and information material with a number of sites of clinical cases, tutorial and teaching files, journals and magisterial lectures on-line. In a near future, the Internet could be applied in the simulation of clinicoradiologic cases or in applications of artificial intelligence with expert systems to support the solution of most complex cases.
Pancreatic Cancer Detection Consortium (PCDC) | Division of Cancer Prevention
[[{"fid":"2256","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"A 3-dimensional image of a human torso highlighting the pancreas.","field_file_image_title_text[und][0][value]":false},"type":"media","field_deltas":{"1":{"format":"default","field_file_image_alt_text[und][0][value]":"A 3-dimensional image of a human torso
Interactive visualization tools for the structural biologist.
Porebski, Benjamin T; Ho, Bosco K; Buckle, Ashley M
2013-10-01
In structural biology, management of a large number of Protein Data Bank (PDB) files and raw X-ray diffraction images often presents a major organizational problem. Existing software packages that manipulate these file types were not designed for these kinds of file-management tasks. This is typically encountered when browsing through a folder of hundreds of X-ray images, with the aim of rapidly inspecting the diffraction quality of a data set. To solve this problem, a useful functionality of the Macintosh operating system (OSX) has been exploited that allows custom visualization plugins to be attached to certain file types. Software plugins have been developed for diffraction images and PDB files, which in many scenarios can save considerable time and effort. The direct visualization of diffraction images and PDB structures in the file browser can be used to identify key files of interest simply by scrolling through a list of files.
A pathologist-designed imaging system for anatomic pathology signout, teaching, and research.
Schubert, E; Gross, W; Siderits, R H; Deckenbaugh, L; He, F; Becich, M J
1994-11-01
Pathology images are derived from gross surgical specimens, light microscopy, immunofluorescence, electron microscopy, molecular diagnostic gels, flow cytometry, image analysis data, and clinical laboratory data in graphic form. We have implemented a network of desktop personal computers (PCs) that allow us to easily capture, store, and retrieve gross and microscopic, anatomic, and research pathology images. System architecture involves multiple image acquisition and retrieval sites and a central file server for storage. The digitized images are conveyed via a local area network to and from image capture or display stations. Acquisition sites consist of a high-resolution camera connected to a frame grabber card in a 486-type personal computer, equipped with 16 MB (Table 1) RAM, a 1.05-gigabyte hard drive, and a 32-bit ethernet card for access to our anatomic pathology reporting system. We have designed a push-button workstation for acquiring and indexing images that does not significantly interfere with surgical pathology sign-out. Advantages of the system include the following: (1) Improving patient care: the availability of gross images at time of microscopic sign-out, verification of recurrence of malignancy from archived images, monitoring of bone marrow engraftment and immunosuppressive intervention after bone marrow/solid organ transplantation on repeat biopsies, and ability to seek instantaneous consultation with any pathologist on the network; (2) enhancing the teaching environment: building a digital surgical pathology atlas, improving the availability of images for conference support, and sharing cases across the network; (3) enhancing research: case study compilation, metastudy analysis, and availability of digitized images for quantitative analysis and permanent/reusable image records for archival study; and (4) other practical and economic considerations: storing case requisition images and hand-drawn diagrams deters the spread of gross room contaminants and results in considerable cost savings in photographic media for conferences, improved quality assurance by porting control stains across the network, and a multiplicity of other advantages that enhance image and information management in pathology.
An analysis of image storage systems for scalable training of deep neural networks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lim, Seung-Hwan; Young, Steven R; Patton, Robert M
This study presents a principled empirical evaluation of image storage systems for training deep neural networks. We employ the Caffe deep learning framework to train neural network models for three different data sets, MNIST, CIFAR-10, and ImageNet. While training the models, we evaluate five different options to retrieve training image data: (1) PNG-formatted image files on local file system; (2) pushing pixel arrays from image files into a single HDF5 file on local file system; (3) in-memory arrays to hold the pixel arrays in Python and C++; (4) loading the training data into LevelDB, a log-structured merge tree based key-valuemore » storage; and (5) loading the training data into LMDB, a B+tree based key-value storage. The experimental results quantitatively highlight the disadvantage of using normal image files on local file systems to train deep neural networks and demonstrate reliable performance with key-value storage based storage systems. When training a model on the ImageNet dataset, the image file option was more than 17 times slower than the key-value storage option. Along with measurements on training time, this study provides in-depth analysis on the cause of performance advantages/disadvantages of each back-end to train deep neural networks. We envision the provided measurements and analysis will shed light on the optimal way to architect systems for training neural networks in a scalable manner.« less
ERIC Educational Resources Information Center
Sutirman; Muhyadi; Surjono, Herman Dwi
2017-01-01
This study aims to investigate the learning implementation of electronic filing and problems faced by teachers in learning implementing of electronic filing. This study is a descriptive research with qualitative approach. Collecting data used interview and documentation techniques. The research subjects consisted of 29 teachers who teach Filing…
Single mimivirus particles intercepted and imaged with an X-ray laser (CXIDB ID 1)
Seibert, M. Marvin; Ekeberg, Tomas; Maia, Filipe R.N.C.
2011-02-02
These are the files used to reconstruct the images in the paper "Single Mimivirus particles intercepted and imaged with an X-ray laser". Besides the diffracted intensities, the Hawk configuration files used for the reconstructions are also provided. The files from CXIDB ID 1 are the pattern and configuration files for the pattern showed in Figure 2a in the paper.
Single mimivirus particles intercepted and imaged with an X-ray laser (CXIDB ID 2)
Seibert, M. Marvin; Ekeberg, Tomas
2011-02-02
These are the files used to reconstruct the images in the paper "Single Mimivirus particles intercepted and imaged with an X-ray laser". Besides the diffracted intensities, the Hawk configuration files used for the reconstructions are also provided. The files from CXIDB ID 2 are the pattern and configuration files for the pattern showed in Figure 2b in the paper.
Arkansas and Louisiana Aeromagnetic and Gravity Maps and Data - A Website for Distribution of Data
Bankey, Viki; Daniels, David L.
2008-01-01
This report contains digital data, image files, and text files describing data formats for aeromagnetic and gravity data used to compile the State aeromagnetic and gravity maps of Arkansas and Louisiana. The digital files include grids, images, ArcInfo, and Geosoft compatible files. In some of the data folders, ASCII files with the extension 'txt' describe the format and contents of the data files. Read the 'txt' files before using the data files.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-27
... already a U.S. citizen or a Lawful Permanent Resident, but you will not be penalized if you do. Group... specifications: Image File Format: The miage must be in the Joint Photographic Experts Group (JPEG) format. Image... in the Joint Photographic Experts Group (JPEG) format. Image File Size: The maximum image file size...
Effect of combined digital imaging parameters on endodontic file measurements.
de Oliveira, Matheus Lima; Pinto, Geraldo Camilo de Souza; Ambrosano, Glaucia Maria Bovi; Tosoni, Guilherme Monteiro
2012-10-01
This study assessed the effect of the combination of a dedicated endodontic filter, spatial resolution, and contrast resolution on the determination of endodontic file lengths. Forty extracted single-rooted teeth were x-rayed with K-files (ISO size 10 and 15) in the root canals. Images were acquired using the VistaScan system (Dürr Dental, Beitigheim-Bissingen, Germany) under different combining parameters of spatial resolution (10 and 25 line pairs per millimeter [lp/mm]) and contrast resolution (8- and 16-bit depths). Subsequently, a dedicated endodontic filter was applied on the 16-bit images, creating 2 additional parameters. Six observers measured the length of the endodontic files in the root canals using the software that accompanies the system. The mean values of the actual file lengths and the measurements of the radiographic images were submitted to 1-way analysis of variance and the Tukey test at a level of significance of 5%. The intraobserver reproducibility was assessed by the intraclass correlation coefficient. All combined image parameters showed excellent intraobserver agreement with intraclass correlation coefficient means higher than 0.98. The imaging parameter of 25 lp/mm and 16 bit associated with the use of the endodontic filter did not differ significantly from the actual file lengths when both file sizes were analyzed together or separately (P > .05). When the size 15 file was evaluated separately, only 8-bit images differed significantly from the actual file lengths (P ≤ .05). The combination of an endodontic filter with high spatial resolution and high contrast resolution is recommended for the determination of file lengths when using storage phosphor plates. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Teaching Using Cabri--With a Little Help from Prepared Files.
ERIC Educational Resources Information Center
Mackrell, Kate
2002-01-01
Describes lessons with year 7 and year 9 classes that used the ATM Active Geometry package. Presents the main activities and how to use prepared files in the geometry package for mathematics instruction. (KHR)
Electronic Photography at the NASA Langley Research Center
NASA Technical Reports Server (NTRS)
Holm, Jack; Judge, Nancianne
1995-01-01
An electronic photography facility has been established in the Imaging & Photographic Technology Section, Visual Imaging Branch, at the NASA Langley Research Center (LaRC). The purpose of this facility is to provide the LaRC community with access to digital imaging technology. In particular, capabilities have been established for image scanning, direct image capture, optimized image processing for storage, image enhancement, and optimized device dependent image processing for output. Unique approaches include: evaluation and extraction of the entire film information content through scanning; standardization of image file tone reproduction characteristics for optimal bit utilization and viewing; education of digital imaging personnel on the effects of sampling and quantization to minimize image processing related information loss; investigation of the use of small kernel optimal filters for image restoration; characterization of a large array of output devices and development of image processing protocols for standardized output. Currently, the laboratory has a large collection of digital image files which contain essentially all the information present on the original films. These files are stored at 8-bits per color, but the initial image processing was done at higher bit depths and/or resolutions so that the full 8-bits are used in the stored files. The tone reproduction of these files has also been optimized so the available levels are distributed according to visual perceptibility. Look up tables are available which modify these files for standardized output on various devices, although color reproduction has been allowed to float to some extent to allow for full utilization of output device gamut.
Images are added via the Drupal WebCMS Editor. Once an image is uploaded onto a page, it is available via the Library and your files. You can edit the metadata, delete the image permanently, and/or replace images on the Files tab.
Early Detection | Division of Cancer Prevention
[[{"fid":"171","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"Early Detection Research Group Homepage Logo","field_file_image_title_text[und][0][value]":"Early Detection Research Group Homepage Logo","field_folder[und]":"15"},"type":"media","field_deltas":{"1":{"format":"default","field_file_image_alt_text[und][0][value]":"Early
Developing Database Files for Student Use.
ERIC Educational Resources Information Center
Warner, Michael
1988-01-01
Presents guidelines for creating student database files that supplement classroom teaching. Highlights include determining educational objectives, planning the database with computer specialists and subject area specialists, data entry, and creating student worksheets. Specific examples concerning elements of the periodic table and…
Main image file tape description
Warriner, Howard W.
1980-01-01
This Main Image File Tape document defines the data content and file structure of the Main Image File Tape (MIFT) produced by the EROS Data Center (EDC). This document also defines an INQUIRY tape, which is just a subset of the MIFT. The format of the INQUIRY tape is identical to the MIFT except for two records; therefore, with the exception of these two records (described elsewhere in this document), every remark made about the MIFT is true for the INQUIRY tape.
Kal, Betül Ilhan; Baksi, B Güniz; Dündar, Nesrin; Sen, Bilge Hakan
2007-02-01
The aim of this study was to compare the accuracy of endodontic file lengths after application of various image enhancement modalities. Endodontic files of three different ISO sizes were inserted in 20 single-rooted extracted permanent mandibular premolar teeth and standardized images were obtained. Original digital images were then enhanced using five processing algorithms. Six evaluators measured the length of each file on each image. The measurements from each processing algorithm and each file size were compared using repeated measures ANOVA and Bonferroni tests (P = 0.05). Paired t test was performed to compare the measurements with the true lengths of the files (P = 0.05). All of the processing algorithms provided significantly shorter measurements than the true length of each file size (P < 0.05). The threshold enhancement modality produced significantly higher mean error values (P < 0.05), while there was no significant difference among the other enhancement modalities (P > 0.05). Decrease in mean error value was observed with increasing file size (P < 0.05). Invert, contrast/brightness and edge enhancement algorithms may be recommended for accurate file length measurements when utilizing storage phosphor plates.
Data Science Bowl Launched to Improve Lung Cancer Screening | Division of Cancer Prevention
[[{"fid":"2078","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"Data Science Bowl Logo","field_file_image_title_text[und][0][value]":"Data Science Bowl Logo","field_folder[und]":"76"},"type":"media","field_deltas":{"1":{"format":"default","field_file_image_alt_text[und][0][value]":"Data Science Bowl
BOREAS RSS-14 Level-1a GOES-8 Visible, IR and Water Vapor Images
NASA Technical Reports Server (NTRS)
Hall, Forrest G. (Editor); Newcomer, Jeffrey A.; Faysash, David; Cooper, Harry J.; Smith, Eric A.
2000-01-01
The BOREAS RSS-14 team collected and processed several GOES-7 and GOES-8 image data sets that covered the BOREAS study region. The level-1a GOES-8 images were created by BORIS personnel from the level-1 images delivered by FSU personnel. The data cover 14-Jul-1995 to 21-Sep-1995 and 12-Feb-1996 to 03-Oct-1996. The data start out as three bands with 8-bit pixel values and end up as five bands with 10-bit pixel values. No major problems with the data have been identified. The differences between the level-1 and level-1a GOES-8 data are the formatting and packaging of the data. The images missing from the temporal series of level-1 GOES-8 images were zero-filled by BORIS staff to create files consistent in size and format. In addition, BORIS staff packaged all the images of a given type from a given day into a single file, removed the header information from the individual level-1 files, and placed it into a single descriptive ASCII header file. The data are contained in binary image format files. Due to the large size of the images, the level-1a GOES-8 data are not contained on the BOREAS CD-ROM set. An inventory listing file is supplied on the CD-ROM to inform users of what data were collected. The level-1a GOES-8 image data are available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC). See sections 15 and 16 for more information. The data files are available on a CD-ROM (see document number 20010000884).
Integration of DICOM and openEHR standards
NASA Astrophysics Data System (ADS)
Wang, Ying; Yao, Zhihong; Liu, Lei
2011-03-01
The standard format for medical imaging storage and transmission is DICOM. openEHR is an open standard specification in health informatics that describes the management and storage, retrieval and exchange of health data in electronic health records. Considering that the integration of DICOM and openEHR is beneficial to information sharing, on the basis of XML-based DICOM format, we developed a method of creating a DICOM Imaging Archetype in openEHR to enable the integration of DICOM and openEHR. Each DICOM file contains abundant imaging information. However, because reading a DICOM involves looking up the DICOM Data Dictionary, the readability of a DICOM file has been limited. openEHR has innovatively adopted two level modeling method, making clinical information divided into lower level, the information model, and upper level, archetypes and templates. But one critical challenge posed to the development of openEHR is the information sharing problem, especially in imaging information sharing. For example, some important imaging information cannot be displayed in an openEHR file. In this paper, to enhance the readability of a DICOM file and semantic interoperability of an openEHR file, we developed a method of mapping a DICOM file to an openEHR file by adopting the form of archetype defined in openEHR. Because an archetype has a tree structure, after mapping a DICOM file to an openEHR file, the converted information is structuralized in conformance with openEHR format. This method enables the integration of DICOM and openEHR and data exchange without losing imaging information between two standards.
Accessible and informative sectioned images, color-coded images, and surface models of the ear.
Park, Hyo Seok; Chung, Min Suk; Shin, Dong Sun; Jung, Yong Wook; Park, Jin Seo
2013-08-01
In our previous research, we created state-of-the-art sectioned images, color-coded images, and surface models of the human ear. Our ear data would be more beneficial and informative if they were more easily accessible. Therefore, the purpose of this study was to distribute the browsing software and the PDF file in which ear images are to be readily obtainable and freely explored. Another goal was to inform other researchers of our methods for establishing the browsing software and the PDF file. To achieve this, sectioned images and color-coded images of ear were prepared (voxel size 0.1 mm). In the color-coded images, structures related to hearing, equilibrium, and structures originated from the first and second pharyngeal arches were segmented supplementarily. The sectioned and color-coded images of right ear were added to the browsing software, which displayed the images serially along with structure names. The surface models were reconstructed to be combined into the PDF file where they could be freely manipulated. Using the browsing software and PDF file, sectional and three-dimensional shapes of ear structures could be comprehended in detail. Furthermore, using the PDF file, clinical knowledge could be identified through virtual otoscopy. Therefore, the presented educational tools will be helpful to medical students and otologists by improving their knowledge of ear anatomy. The browsing software and PDF file can be downloaded without charge and registration at our homepage (http://anatomy.dongguk.ac.kr/ear/). Copyright © 2013 Wiley Periodicals, Inc.
Zmijan, Robert; Jonnalagadda, Umesh S.; Carugo, Dario; Kochi, Yu; Lemm, Elizabeth; Packham, Graham; Hill, Martyn
2015-01-01
We demonstrate an imaging flow cytometer that uses acoustic levitation to assemble cells and other particles into a sheet structure. This technique enables a high resolution, low noise CMOS camera to capture images of thousands of cells with each frame. While ultrasonic focussing has previously been demonstrated for 1D cytometry systems, extending the technology to a planar, much higher throughput format and integrating imaging is non-trivial, and represents a significant jump forward in capability, leading to diagnostic possibilities not achievable with current systems. A galvo mirror is used to track the images of the moving cells permitting exposure times of 10 ms at frame rates of 50 fps with motion blur of only a few pixels. At 80 fps, we demonstrate a throughput of 208 000 beads per second. We investigate the factors affecting motion blur and throughput, and demonstrate the system with fluorescent beads, leukaemia cells and a chondrocyte cell line. Cells require more time to reach the acoustic focus than beads, resulting in lower throughputs; however a longer device would remove this constraint. PMID:29456838
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-01
... need to submit a photo for a child who is already a U.S. citizen or a Legal Permanent Resident. Group... Joint Photographic Experts Group (JPEG) format; it must have a maximum image file size of two hundred... (dpi); the image file format in Joint Photographic Experts Group (JPEG) format; the maximum image file...
NIH Seeks Input on In-patient Clinical Research Areas | Division of Cancer Prevention
[[{"fid":"2476","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"Aerial view of the National Institutes of Health Clinical Center (Building 10) in Bethesda, Maryland.","field_file_image_title_text[und][0][value]":false},"type":"media","field_deltas":{"1":{"format":"default","field_file_image_alt_text[und][0][value]":"Aerial view of
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-23
... application image files and most registration image files. The USPTO is nearing completion of a multi-year... images are stored in TICRS. To date in Fiscal Year 2011, almost 99% of applications were filed...: September 19, 2011. David J. Kappos, Under Secretary of Commerce for Intellectual Property and Director of...
Cardio-PACs: a new opportunity
NASA Astrophysics Data System (ADS)
Heupler, Frederick A., Jr.; Thomas, James D.; Blume, Hartwig R.; Cecil, Robert A.; Heisler, Mary
2000-05-01
It is now possible to replace film-based image management in the cardiac catheterization laboratory with a Cardiology Picture Archiving and Communication System (Cardio-PACS) based on digital imaging technology. The first step in the conversion process is installation of a digital image acquisition system that is capable of generating high-quality DICOM-compatible images. The next three steps, which are the subject of this presentation, involve image display, distribution, and storage. Clinical requirements and associated cost considerations for these three steps are listed below: Image display: (1) Image quality equal to film, with DICOM format, lossless compression, image processing, desktop PC-based with color monitor, and physician-friendly imaging software; (2) Performance specifications include: acquire 30 frames/sec; replay 15 frames/sec; access to file server 5 seconds, and to archive 5 minutes; (3) Compatibility of image file, transmission, and processing formats; (4) Image manipulation: brightness, contrast, gray scale, zoom, biplane display, and quantification; (5) User-friendly control of image review. Image distribution: (1) Standard IP-based network between cardiac catheterization laboratories, file server, long-term archive, review stations, and remote sites; (2) Non-proprietary formats; (3) Bidirectional distribution. Image storage: (1) CD-ROM vs disk vs tape; (2) Verification of data integrity; (3) User-designated storage capacity for catheterization laboratory, file server, long-term archive. Costs: (1) Image acquisition equipment, file server, long-term archive; (2) Network infrastructure; (3) Review stations and software; (4) Maintenance and administration; (5) Future upgrades and expansion; (6) Personnel.
Innovative methods for knowledge transfer
NASA Astrophysics Data System (ADS)
Goanta, A. M.
2015-11-01
At this time, learning takes place, either with classic books on paper support or using books scanned or drawn and further converted into PDF or PPT files that are printed on type support CD / DVD. The latter modern means of learning, the study adds live on the Internet using search engines and not least e-learning method, which allows the study of bibliographic related materials in PDF or PPT, stacked and grouped on the basis of a curriculum imposed which can be accessed on a website via a user name and password. Innovative methods come to successfully use other file types than those mentioned above. The graphics in teaching technical subjects such as descriptive geometry can be achieved using animated PowerPoint files, allowing for visualization of steps to be taken, in the case of solving by drawing a descriptive geometry. Another innovative method relies on the use of HTML files, inspired by related sites help design software packages that can be used when teaching descriptive geometry that the technical design. Through this work, the author has proposed to present a new innovative method, which is inspired by the methods listed above, but involves using AVI files to teaching of computer-assisted type graphics or info graphics. In general this new author's method lends itself particularly well to the teaching of the use of software packages because the student actually see the place from where the delivered command is accessed and contextual options of right button of the mouse. These laboratory courses or mentoring can be freestanding cards support CD / DVD or can be posted on websites with restricted access based on user name and password. Practically paper presents the methodology of creating courses and tutorials in AVI format, and how to monitor the degree of accessing the website, on which there were posted mentioned teaching materials, using the tools offered by Google Analytics. The results consist of graphical work, about the degree of access to educational materials, made on the basis of various criteria, such as the: time of access, access location, age of those who accessed, chapters accessed, etc. Finally the author presents his findings on the benefits of this method.
Maryam, Ehsani; Farida, Abesi; Farhad, Akbarzade; Soraya, Khafri
2013-11-01
Obtaining the proper working length in endodontic treatment is essential. The aim of this study was to compare the working length (WL) assessment of small diameter K-files using the two different digital imaging methods. The samples for this in-vitro experimental study consisted of 40 extracted single-rooted premolars. After access cavity preparation, the ISO files no. 6, 8, and 10 stainless steel K-files were inserted in the canals in the three different lengths to evaluate the results in a blinded manner: At the level of apical foramen(actual)1 mm short of apical foramen2 mm short of apical foramen A digital caliper was used to measure the length of the files which was considered as the Gold Standard. Five observers (two oral and maxillofacial radiologists and three endodontists) observed the digital radiographs which were obtained using PSP and CCD digital imaging sensors. The collected data were analyzed by SPSS 17 and Repeated Measures Paired T-test. In WL assessment of small diameter K-files, a significant statistical relationship was seen among the observers of two digital imaging techniques (P<0.001). However, no significant difference was observed between the two digital techniques in WL assessment of small diameter K-files (P<0.05). PSP and CCD digital imaging techniques were similar in WL assessment of canals using no. 6, 8, and 10 K-files.
DICOM to print, 35-mm slides, web, and video projector: tutorial using Adobe Photoshop.
Gurney, Jud W
2002-10-01
Preparing images for publication has dealt with film and the photographic process. With picture archiving and communications systems, many departments will no longer produce film. This will change how images are produced for publication. DICOM, the file format for radiographic images, has to be converted and then prepared for traditional publication, 35-mm slides, the newest techniques of video projection, and the World Wide Web. Tagged image file format is the common format for traditional print publication, whereas joint photographic expert group is the current file format for the World Wide Web. Each medium has specific requirements that can be met with a common image-editing program such as Adobe Photoshop (Adobe Systems, San Jose, CA). High-resolution images are required for print, a process that requires interpolation. However, the Internet requires images with a small file size for rapid transmission. The resolution of each output differs and the image resolution must be optimized to match the output of the publishing medium.
Hybrid cryptosystem for image file using elgamal and double playfair cipher algorithm
NASA Astrophysics Data System (ADS)
Hardi, S. M.; Tarigan, J. T.; Safrina, N.
2018-03-01
In this paper, we present an implementation of an image file encryption using hybrid cryptography. We chose ElGamal algorithm to perform asymmetric encryption and Double Playfair for the symmetric encryption. Our objective is to show that these algorithms are capable to encrypt an image file with an acceptable running time and encrypted file size while maintaining the level of security. The application was built using C# programming language and ran as a stand alone desktop application under Windows Operating System. Our test shows that the system is capable to encrypt an image with a resolution of 500×500 to a size of 976 kilobytes with an acceptable running time.
Community Oncology and Prevention Trials | Division of Cancer Prevention
[[{"fid":"168","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"Early Detection Research Group Homepage Image","field_file_image_title_text[und][0][value]":"Early Detection Research Group Homepage Image","field_folder[und]":"15"},"type":"media","attributes":{"alt":"Early Detection Research Group Homepage Image","title":"Early
Transforming Dermatologic Imaging for the Digital Era: Metadata and Standards.
Caffery, Liam J; Clunie, David; Curiel-Lewandrowski, Clara; Malvehy, Josep; Soyer, H Peter; Halpern, Allan C
2018-01-17
Imaging is increasingly being used in dermatology for documentation, diagnosis, and management of cutaneous disease. The lack of standards for dermatologic imaging is an impediment to clinical uptake. Standardization can occur in image acquisition, terminology, interoperability, and metadata. This paper presents the International Skin Imaging Collaboration position on standardization of metadata for dermatologic imaging. Metadata is essential to ensure that dermatologic images are properly managed and interpreted. There are two standards-based approaches to recording and storing metadata in dermatologic imaging. The first uses standard consumer image file formats, and the second is the file format and metadata model developed for the Digital Imaging and Communication in Medicine (DICOM) standard. DICOM would appear to provide an advantage over using consumer image file formats for metadata as it includes all the patient, study, and technical metadata necessary to use images clinically. Whereas, consumer image file formats only include technical metadata and need to be used in conjunction with another actor-for example, an electronic medical record-to supply the patient and study metadata. The use of DICOM may have some ancillary benefits in dermatologic imaging including leveraging DICOM network and workflow services, interoperability of images and metadata, leveraging existing enterprise imaging infrastructure, greater patient safety, and better compliance to legislative requirements for image retention.
Image processing tool for automatic feature recognition and quantification
Chen, Xing; Stoddard, Ryan J.
2017-05-02
A system for defining structures within an image is described. The system includes reading of an input file, preprocessing the input file while preserving metadata such as scale information and then detecting features of the input file. In one version the detection first uses an edge detector followed by identification of features using a Hough transform. The output of the process is identified elements within the image.
Creating and indexing teaching files from free-text patient reports.
Johnson, D. B.; Chu, W. W.; Dionisio, J. D.; Taira, R. K.; Kangarloo, H.
1999-01-01
Teaching files based on real patient data can enhance the education of students, staff and other colleagues. Although information retrieval system can index free-text documents using keywords, these systems do not work well where content bearing terms (e.g., anatomy descriptions) frequently appears. This paper describes a system that uses multi-word indexing terms to provide access to free-text patient reports. The utilization of multi-word indexing allows better modeling of the content of medical reports, thus improving retrieval performance. The method used to select indexing terms as well as early evaluation of retrieval performance is discussed. PMID:10566473
Determining the Completeness of the Nimbus Meteorological Data Archive
NASA Technical Reports Server (NTRS)
Johnson, James; Moses, John; Kempler, Steven; Zamkoff, Emily; Al-Jazrawi, Atheer; Gerasimov, Irina; Trivedi, Bhagirath
2011-01-01
NASA launched the Nimbus series of meteorological satellites in the 1960s and 70s. These satellites carried instruments for making observations of the Earth in the visible, infrared, ultraviolet, and microwave wavelengths. The original data archive consisted of a combination of digital data written to 7-track computer tapes and on various film media. Many of these data sets are now being migrated from the old media to the GES DISC modern online archive. The process involves recovering the digital data files from tape as well as scanning images of the data from film strips. Some of the challenges of archiving the Nimbus data include the lack of any metadata from these old data sets. Metadata standards and self-describing data files did not exist at that time, and files were written on now obsolete hardware systems and outdated file formats. This requires creating metadata by reading the contents of the old data files. Some digital data files were corrupted over time, or were possibly improperly copied at the time of creation. Thus there are data gaps in the collections. The film strips were stored in boxes and are now being scanned as JPEG-2000 images. The only information describing these images is what was written on them when they were originally created, and sometimes this information is incomplete or missing. We have the ability to cross-reference the scanned images against the digital data files to determine which of these best represents the data set from the various missions, or to see how complete the data sets are. In this presentation we compared data files and scanned images from the Nimbus-2 High-Resolution Infrared Radiometer (HRIR) for September 1966 to determine whether the data and images are properly archived with correct metadata.
TM digital image products for applications. [computer compatible tapes
NASA Technical Reports Server (NTRS)
Barker, J. L.; Gunther, F. J.; Abrams, R. B.; Ball, D.
1984-01-01
The image characteristics of digital data generated by LANDSAT 4 thematic mapper (TM) are discussed. Digital data from the TM resides in tape files at various stages of image processing. Within each image data file, the image lines are blocked by a factor of either 5 for a computer compatible tape CCT-BT, or 4 for a CCT-AT and CCT-PT; in each format, the image file has a different format. Nominal geometric corrections which provide proper geodetic relationships between different parts of the image are available only for the CCT-PT. It is concluded that detector 3 of band 5 on the TM does not respond; this channel of data needs replacement. The empty bin phenomenon in CCT-AT images results from integer truncations of mixed-mode arithmetric operations.
Learning to File: Reconfiguring Information and Information Work in the Early Twentieth Century.
Robertson, Craig
2017-01-01
This article uses textbooks and advertisements to explore the formal and informal ways in which people were introduced to vertical filing in the early twentieth century. Through the privileging of "system" an ideal mode of paperwork emerged in which a clerk could "grasp" information simply by hand without having to understand or comprehend its content. A file clerk's hands and fingers became central to the representation and teaching of filing. In this way, filing offered an example of a distinctly modern form of information work. Filing textbooks sought to enhance dexterity as the rapid handling of paper came to represent information as something that existed in discrete units, in bits that could be easily extracted. Advertisements represented this mode of information work in its ideal form when they frequently erased the worker or reduced him or her to hands, as "instant" filing became "automatic" filing, with the filing cabinet presented as a machine.
Galileo SSI/Ida Radiometrically Calibrated Images V1.0
NASA Astrophysics Data System (ADS)
Domingue, D. L.
2016-05-01
This data set includes Galileo Orbiter SSI radiometrically calibrated images of the asteroid 243 Ida, created using ISIS software and assuming nadir pointing. This is an original delivery of radiometrically calibrated files, not an update to existing files. All images archived include the asteroid within the image frame. Calibration was performed in 2013-2014.
NASA Astrophysics Data System (ADS)
Fletcher, Alex; Yoo, Terry S.
2004-04-01
Public databases today can be constructed with a wide variety of authoring and management structures. The widespread appeal of Internet search engines suggests that public information be made open and available to common search strategies, making accessible information that would otherwise be hidden by the infrastructure and software interfaces of a traditional database management system. We present the construction and organizational details for managing NOVA, the National Online Volumetric Archive. As an archival effort of the Visible Human Project for supporting medical visualization research, archiving 3D multimodal radiological teaching files, and enhancing medical education with volumetric data, our overall database structure is simplified; archives grow by accruing information, but seldom have to modify, delete, or overwrite stored records. NOVA is being constructed and populated so that it is transparent to the Internet; that is, much of its internal structure is mirrored in HTML allowing internet search engines to investigate, catalog, and link directly to the deep relational structure of the collection index. The key organizational concept for NOVA is the Image Content Group (ICG), an indexing strategy for cataloging incoming data as a set structure rather than by keyword management. These groups are managed through a series of XML files and authoring scripts. We cover the motivation for Image Content Groups, their overall construction, authorship, and management in XML, and the pilot results for creating public data repositories using this strategy.
Römpp, Andreas; Schramm, Thorsten; Hester, Alfons; Klinkert, Ivo; Both, Jean-Pierre; Heeren, Ron M A; Stöckli, Markus; Spengler, Bernhard
2011-01-01
Imaging mass spectrometry is the method of scanning a sample of interest and generating an "image" of the intensity distribution of a specific analyte. The data sets consist of a large number of mass spectra which are usually acquired with identical settings. Existing data formats are not sufficient to describe an MS imaging experiment completely. The data format imzML was developed to allow the flexible and efficient exchange of MS imaging data between different instruments and data analysis software.For this purpose, the MS imaging data is divided in two separate files. The mass spectral data is stored in a binary file to ensure efficient storage. All metadata (e.g., instrumental parameters, sample details) are stored in an XML file which is based on the standard data format mzML developed by HUPO-PSI. The original mzML controlled vocabulary was extended to include specific parameters of imaging mass spectrometry (such as x/y position and spatial resolution). The two files (XML and binary) are connected by offset values in the XML file and are unambiguously linked by a universally unique identifier. The resulting datasets are comparable in size to the raw data and the separate metadata file allows flexible handling of large datasets.Several imaging MS software tools already support imzML. This allows choosing from a (growing) number of processing tools. One is no longer limited to proprietary software, but is able to use the processing software which is best suited for a specific question or application. On the other hand, measurements from different instruments can be compared within one software application using identical settings for data processing. All necessary information for evaluating and implementing imzML can be found at http://www.imzML.org .
Koch, Jon D; Smith, Nicholas A; Garces, Daniel; Gao, Luyang; Olsen, F Kris
2014-03-01
Root canal irrigation is vital to thorough debridement and disinfection, but the mechanisms that contribute to its effectiveness are complex and uncertain. Traditionally, studies in this area have relied on before-and-after static comparisons to assess effectiveness, but new in situ tools are being developed to provide real-time assessments of irrigation. The aim in this work was to measure a cross section of the velocity field in the fluid flow around a polymer rotary finishing file in a model root canal. Fluorescent microparticles were seeded into an optically accessible acrylic root canal model. A polymer rotary finishing file was activated in a static position. After laser excitation, fluorescence from the microparticles was imaged onto a frame-transfer camera. Two consecutive images were cross-correlated to provide a measurement of a projected, 2-dimensional velocity field. The method reveals that fluid velocities can be much higher than the velocity of the file because of the shape of the file. Furthermore, these high velocities are in the axial direction of the canal rather than only in the direct of motion of the file. Particle image velocimetry indicates that fluid velocities induced by the rotating file can be much larger than the speed of the file. Particle image velocimetry can provide qualitative insight and quantitative measurements that may be useful for validating computational fluid dynamic models and connecting clinical observations to physical explanations in dental research. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Syllabus for a Course in File Management. Curriculum for the Information Sciences, Report No. 9.
ERIC Educational Resources Information Center
Carroll, John M.
The course treats the organization and structure of files including relationships between information representation and processing techniques, transformations between storage media, and the referencing of information as related to the structure of its representation. The intent of the course is fourfold: (a) To teach the underlying principles of…
Code of Federal Regulations, 2013 CFR
2013-07-01
... will be given for each course. (5) A description of the teaching methods and the course materials which...; information required; time for approval; method for disapproval; commencement of training; approval of....3 Training plans; time of submission; where filed; information required; time for approval; method...
Code of Federal Regulations, 2011 CFR
2011-07-01
... will be given for each course. (5) A description of the teaching methods and the course materials which...; information required; time for approval; method for disapproval; commencement of training; approval of....3 Training plans; time of submission; where filed; information required; time for approval; method...
Code of Federal Regulations, 2012 CFR
2012-07-01
... will be given for each course. (5) A description of the teaching methods and the course materials which...; information required; time for approval; method for disapproval; commencement of training; approval of....3 Training plans; time of submission; where filed; information required; time for approval; method...
Code of Federal Regulations, 2010 CFR
2010-07-01
... will be given for each course. (5) A description of the teaching methods and the course materials which...; information required; time for approval; method for disapproval; commencement of training; approval of....3 Training plans; time of submission; where filed; information required; time for approval; method...
Code of Federal Regulations, 2014 CFR
2014-07-01
... will be given for each course. (5) A description of the teaching methods and the course materials which...; information required; time for approval; method for disapproval; commencement of training; approval of....3 Training plans; time of submission; where filed; information required; time for approval; method...
Image editing with Adobe Photoshop 6.0.
Caruso, Ronald D; Postel, Gregory C
2002-01-01
The authors introduce Photoshop 6.0 for radiologists and demonstrate basic techniques of editing gray-scale cross-sectional images intended for publication and for incorporation into computerized presentations. For basic editing of gray-scale cross-sectional images, the Tools palette and the History/Actions palette pair should be displayed. The History palette may be used to undo a step or series of steps. The Actions palette is a menu of user-defined macros that save time by automating an action or series of actions. Converting an image to 8-bit gray scale is the first editing function. Cropping is the next action. Both decrease file size. Use of the smallest file size necessary for the purpose at hand is recommended. Final file size for gray-scale cross-sectional neuroradiologic images (8-bit, single-layer TIFF [tagged image file format] at 300 pixels per inch) intended for publication varies from about 700 Kbytes to 3 Mbytes. Final file size for incorporation into computerized presentations is about 10-100 Kbytes (8-bit, single-layer, gray-scale, high-quality JPEG [Joint Photographic Experts Group]), depending on source and intended use. Editing and annotating images before they are inserted into presentation software is highly recommended, both for convenience and flexibility. Radiologists should find that image editing can be carried out very rapidly once the basic steps are learned and automated. Copyright RSNA, 2002
76 FR 24467 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-02
... Schedule A Image to be effective 12/20/2010. Filed Date: 04/25/2011. Accession Number: 20110425-5169... per Order in ER11-2750-000 to resubmit the Schedule A Image to be effective 12/28/2010. Filed Date: 04... (toll free). For TTY, call (202) 502-8659. Dated: April 26, 2011. Nathaniel J. Davis, Sr., Deputy...
Yoshihiro, Akiko; Nakata, Norio; Harada, Junta; Tada, Shimpei
2002-01-01
Although local area networks (LANs) are commonplace in hospital-based radiology departments today, wireless LANs are still relatively unknown and untried. A linked wireless reporting system was developed to improve work throughput and efficiency. It allows radiologists, physicians, and technologists to review current radiology reports and images and instantly compare them with reports and images from previous examinations. This reporting system also facilitates creation of teaching files quickly, easily, and accurately. It consists of a Digital Imaging and Communications in Medicine 3.0-based picture archiving and communication system (PACS), a diagnostic report server, and portable laptop computers. The PACS interfaces with magnetic resonance imagers, computed tomographic scanners, and computed radiography equipment. The same kind of functionality is achievable with a wireless LAN as with a wired LAN, with comparable bandwidth but with less cabling infrastructure required. This wireless system is presently incorporated into the operations of the emergency and radiology departments, with future plans calling for applications in operating rooms, outpatient departments, all hospital wards, and intensive care units. No major problems have been encountered with the system, which is in constant use and appears to be quite successful. Copyright RSNA, 2002
Why can't I manage my digital images like MP3s? The evolution and intent of multimedia metadata
NASA Astrophysics Data System (ADS)
Goodrum, Abby; Howison, James
2005-01-01
This paper considers the deceptively simple question: Why can't digital images be managed in the simple and effective manner in which digital music files are managed? We make the case that the answer is different treatments of metadata in different domains with different goals. A central difference between the two formats stems from the fact that digital music metadata lookup services are collaborative and automate the movement from a digital file to the appropriate metadata, while image metadata services do not. To understand why this difference exists we examine the divergent evolution of metadata standards for digital music and digital images and observed that the processes differ in interesting ways according to their intent. Specifically music metadata was developed primarily for personal file management and community resource sharing, while the focus of image metadata has largely been on information retrieval. We argue that lessons from MP3 metadata can assist individuals facing their growing personal image management challenges. Our focus therefore is not on metadata for cultural heritage institutions or the publishing industry, it is limited to the personal libraries growing on our hard-drives. This bottom-up approach to file management combined with p2p distribution radically altered the music landscape. Might such an approach have a similar impact on image publishing? This paper outlines plans for improving the personal management of digital images-doing image metadata and file management the MP3 way-and considers the likelihood of success.
Why can't I manage my digital images like MP3s? The evolution and intent of multimedia metadata
NASA Astrophysics Data System (ADS)
Goodrum, Abby; Howison, James
2004-12-01
This paper considers the deceptively simple question: Why can"t digital images be managed in the simple and effective manner in which digital music files are managed? We make the case that the answer is different treatments of metadata in different domains with different goals. A central difference between the two formats stems from the fact that digital music metadata lookup services are collaborative and automate the movement from a digital file to the appropriate metadata, while image metadata services do not. To understand why this difference exists we examine the divergent evolution of metadata standards for digital music and digital images and observed that the processes differ in interesting ways according to their intent. Specifically music metadata was developed primarily for personal file management and community resource sharing, while the focus of image metadata has largely been on information retrieval. We argue that lessons from MP3 metadata can assist individuals facing their growing personal image management challenges. Our focus therefore is not on metadata for cultural heritage institutions or the publishing industry, it is limited to the personal libraries growing on our hard-drives. This bottom-up approach to file management combined with p2p distribution radically altered the music landscape. Might such an approach have a similar impact on image publishing? This paper outlines plans for improving the personal management of digital images-doing image metadata and file management the MP3 way-and considers the likelihood of success.
Tsukamoto, Takafumi; Yasunaga, Takuo
2014-11-01
Eos (Extensible object-oriented system) is one of the powerful applications for image processing of electron micrographs. In usual cases, Eos works with only character user interfaces (CUI) under the operating systems (OS) such as OS-X or Linux, not user-friendly. Thus, users of Eos need to be expert at image processing of electron micrographs, and have a little knowledge of computer science, as well. However, all the persons who require Eos does not an expert for CUI. Thus we extended Eos to a web system independent of OS with graphical user interfaces (GUI) by integrating web browser.Advantage to use web browser is not only to extend Eos with GUI, but also extend Eos to work under distributed computational environment. Using Ajax (Asynchronous JavaScript and XML) technology, we implemented more comfortable user-interface on web browser. Eos has more than 400 commands related to image processing for electron microscopy, and the usage of each command is different from each other. Since the beginning of development, Eos has managed their user-interface by using the interface definition file of "OptionControlFile" written in CSV (Comma-Separated Value) format, i.e., Each command has "OptionControlFile", which notes information for interface and its usage generation. Developed GUI system called "Zephyr" (Zone for Easy Processing of HYpermedia Resources) also accessed "OptionControlFIle" and produced a web user-interface automatically, because its mechanism is mature and convenient,The basic actions of client side system was implemented properly and can supply auto-generation of web-form, which has functions of execution, image preview, file-uploading to a web server. Thus the system can execute Eos commands with unique options for each commands, and process image analysis. There remain problems of image file format for visualization and workspace for analysis: The image file format information is useful to check whether the input/output file is correct and we also need to provide common workspace for analysis because the client is physically separated from a server. We solved the file format problem by extension of rules of OptionControlFile of Eos. Furthermore, to solve workspace problems, we have developed two type of system. The first system is to use only local environments. The user runs a web server provided by Eos, access to a web client through a web browser, and manipulate the local files with GUI on the web browser. The second system is employing PIONE (Process-rule for Input/Output Negotiation Environment), which is our developing platform that works under heterogenic distributed environment. The users can put their resources, such as microscopic images, text files and so on, into the server-side environment supported by PIONE, and so experts can write PIONE rule definition, which defines a workflow of image processing. PIONE run each image processing on suitable computers, following the defined rule. PIONE has the ability of interactive manipulation, and user is able to try a command with various setting values. In this situation, we contribute to auto-generation of GUI for a PIONE workflow.As advanced functions, we have developed a module to log user actions. The logs include information such as setting values in image processing, procedure of commands and so on. If we use the logs effectively, we can get a lot of advantages. For example, when an expert may discover some know-how of image processing, other users can also share logs including his know-hows and so we may obtain recommendation workflow of image analysis, if we analyze logs. To implement social platform of image processing for electron microscopists, we have developed system infrastructure, as well. © The Author 2014. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
42 CFR 37.44 - Approval of radiographic facilities that use digital radiography systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... image acquisition, digitization, processing, compression, transmission, display, archiving, and... quality digital chest radiographs by submitting to NIOSH digital radiographic image files of a test object... digital radiographic image files from six or more sample chest radiographs that are of acceptable quality...
42 CFR 37.44 - Approval of radiographic facilities that use digital radiography systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... image acquisition, digitization, processing, compression, transmission, display, archiving, and... quality digital chest radiographs by submitting to NIOSH digital radiographic image files of a test object... digital radiographic image files from six or more sample chest radiographs that are of acceptable quality...
BOREAS RSS-14 Level-2 GOES-7 Shortwave and Longwave Radiation Images
NASA Technical Reports Server (NTRS)
Hall, Forrest G. (Editor); Nickeson, Jaime (Editor); Gu, Jiujing; Smith, Eric A.
2000-01-01
The BOREAS RSS-14 team collected and processed several GOES-7 and GOES-8 image data sets that covered the BOREAS study region. This data set contains images of shortwave and longwave radiation at the surface and top of the atmosphere derived from collected GOES-7 data. The data cover the time period of 05-Feb-1994 to 20-Sep-1994. The images missing from the temporal series were zero-filled to create a consistent sequence of files. The data are stored in binary image format files. Due to the large size of the images, the level-1a GOES-7 data are not contained on the BOREAS CD-ROM set. An inventory listing file is supplied on the CD-ROM to inform users of what data were collected. The level-1a GOES-7 image data are available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC). See sections 15 and 16 for more information. The data files are available on a CD-ROM (see document number 20010000884).
Do Academically Able Teachers Leave Education? The North Carolina Case.
ERIC Educational Resources Information Center
Schlechty, Phillip C.; Vance, Victor S.
1981-01-01
To determine whether academically able teachers are more likely than others to leave the classroom, a study was conducted of the data file of all certified regular classroom teachers who entered teaching in North Carolina from 1973 to 1980 and had no prior teaching experience. (Author/WD)
Mass-storage management for distributed image/video archives
NASA Astrophysics Data System (ADS)
Franchi, Santina; Guarda, Roberto; Prampolini, Franco
1993-04-01
The realization of image/video database requires a specific design for both database structures and mass storage management. This issue has addressed the project of the digital image/video database system that has been designed at IBM SEMEA Scientific & Technical Solution Center. Proper database structures have been defined to catalog image/video coding technique with the related parameters, and the description of image/video contents. User workstations and servers are distributed along a local area network. Image/video files are not managed directly by the DBMS server. Because of their wide size, they are stored outside the database on network devices. The database contains the pointers to the image/video files and the description of the storage devices. The system can use different kinds of storage media, organized in a hierarchical structure. Three levels of functions are available to manage the storage resources. The functions of the lower level provide media management. They allow it to catalog devices and to modify device status and device network location. The medium level manages image/video files on a physical basis. It manages file migration between high capacity media and low access time media. The functions of the upper level work on image/video file on a logical basis, as they archive, move and copy image/video data selected by user defined queries. These functions are used to support the implementation of a storage management strategy. The database information about characteristics of both storage devices and coding techniques are used by the third level functions to fit delivery/visualization requirements and to reduce archiving costs.
Automatic Detection of Steganographic Content
2005-06-30
Practically, it is mostly embedded into the media files, especially the image files. Consequently, a lot of the anti- steganography algorithms work with raw...1: not enough memory * -2: error running the removal algorithm EXPORT IMAGE *StegRemove( IMAGE * image , int *error); 2.8 Steganography Extraction API...researcher just invented a reliable algorithm that can detect the existence of a steganography if it is embedded anywhere in any uncompressed image . The
Graphics-Printing Program For The HP Paintjet Printer
NASA Technical Reports Server (NTRS)
Atkins, Victor R.
1993-01-01
IMPRINT utility computer program developed to print graphics specified in raster files by use of Hewlett-Packard Paintjet(TM) color printer. Reads bit-mapped images from files on UNIX-based graphics workstation and prints out three different types of images: wire-frame images, solid-color images, and gray-scale images. Wire-frame images are in continuous tone or, in case of low resolution, in random gray scale. In case of color images, IMPRINT also prints by use of default palette of solid colors. Written in C language.
40 CFR 265.71 - Use of manifest system.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., § 265.71 was amended by revising paragraph (a)(2), and by adding paragraphs (f), (g), (h), (i), (j), and... operator, the owner or operator may transmit to the system operator an image file of Page 1 of the manifest, or both a data string file and the image file corresponding to Page 1 of the manifest. Any data or...
Software for browsing sectioned images of a dog body and generating a 3D model.
Park, Jin Seo; Jung, Yong Wook
2016-01-01
The goals of this study were (1) to provide accessible and instructive browsing software for sectioned images and a portable document format (PDF) file that includes three-dimensional (3D) models of an entire dog body and (2) to develop techniques for segmentation and 3D modeling that would enable an investigator to perform these tasks without the aid of a computer engineer. To achieve these goals, relatively important or large structures in the sectioned images were outlined to generate segmented images. The sectioned and segmented images were then packaged into browsing software. In this software, structures in the sectioned images are shown in detail and in real color. After 3D models were made from the segmented images, the 3D models were exported into a PDF file. In this format, the 3D models could be manipulated freely. The browsing software and PDF file are available for study by students, for lecture for teachers, and for training for clinicians. These files will be helpful for anatomical study by and clinical training of veterinary students and clinicians. Furthermore, these techniques will be useful for researchers who study two-dimensional images and 3D models. © 2015 Wiley Periodicals, Inc.
Enhancing Web applications in radiology with Java: estimating MR imaging relaxation times.
Dagher, A P; Fitzpatrick, M; Flanders, A E; Eng, J
1998-01-01
Java is a relatively new programming language that has been used to develop a World Wide Web-based tool for estimating magnetic resonance (MR) imaging relaxation times, thereby demonstrating how Java may be used for Web-based radiology applications beyond improving the user interface of teaching files. A standard processing algorithm coded with Java is downloaded along with the hypertext markup language (HTML) document. The user (client) selects the desired pulse sequence and inputs data obtained from a region of interest on the MR images. The algorithm is used to modify selected MR imaging parameters in an equation that models the phenomenon being evaluated. MR imaging relaxation times are estimated, and confidence intervals and a P value expressing the accuracy of the final results are calculated. Design features such as simplicity, object-oriented programming, and security restrictions allow Java to expand the capabilities of HTML by offering a more versatile user interface that includes dynamic annotations and graphics. Java also allows the client to perform more sophisticated information processing and computation than is usually associated with Web applications. Java is likely to become a standard programming option, and the development of stand-alone Java applications may become more common as Java is integrated into future versions of computer operating systems.
NASA Technical Reports Server (NTRS)
Malin, Michael; Revine, Michael; Boyce, Joseph M. (Technical Monitor)
1998-01-01
This compact disk (CD) is part of the Malin Space Science Systems (MSSS) effort to mosaic Clementine I high resolution (HiRes) camera lunar images. These mosaics were developed through calibration and semi-automated registration against the recently released geometrically and photometrically controlled Ultraviolet/Visible (UV/Vis) Basemap Mosaic, which is available through the PDS, as CD-ROM volumes CL_3001-3015. The HiRes mosaics are compiled from non-uniformity corrected, 750 nanometer ("D") filter high resolution observations from the HiRes imaging system onboard the Clementine Spacecraft. These mosaics are spatially warped using the sinusoidal equal-area projection at a scale of 20 m/pixel. The geometric control is provided by the 100 m/pixel U.S. Geological Survey (USGS) Clementine Basemap Mosaic compiled from the 750 nm Ultraviolet/Visible Clementine imaging system. Calibration was achieved by removing the image nonuniformity largely caused by the HiRes system's light intensifier. Also provided are offset and scale factors, achieved by a fit of the HiRes data to the corresponding photometrically calibrated UV/Vis basemap that approximately transform the 8-bit HiRes data to photometric units. The mosaics on this CD were compiled from sub-polar data (latitudes 80 degrees South to 80 degrees North; -80 to +80) within the longitude range 0-30 deg E. The mosaics are divided into tiles that cover approximately 1.75 degrees of latitude and span the longitude range of the mosaicked frames. Images from a given orbit are map projected using the orbit's nominal central latitude. This CD contains ancillary data files that support the HiRes mosaic. These files include browse images with UV/Vis context stored in a Joint Photographic Experts Group (JPEG) format, index files ('imgindx.tab' and 'srcindx.tab') that tabulate the contents of the CD, and documentation files. For more information on the contents and organization of the CD volume set refer to the "FILES, DIRECTORIES AND DISK CONTENTS" section of this document. The image files are organized according to NASA's Planetary Data System (PDS) standards. An image file (tile) is organized as a PDS labeled file containing an "image object".
NASA Technical Reports Server (NTRS)
Malin, Michael; Revine, Michael; Boyce, Joseph M. (Technical Monitor)
1998-01-01
This compact disk (CD) is part of the Malin Space Science Systems (MSSS) effort to mosaic Clementine I high resolution (HiRes) camera lunar images. These mosaics were developed through calibration and semi-automated registration against the recently released geometrically and photometrically controlled Ultraviolet/Visible (UV/Vis) Basemap Mosaic, which is available through the PDS, as CD-ROM volumes CL_3001-3015. The HiRes mosaics are compiled from non-uniformity corrected, 750 nanometer ("D") filter high resolution observations from the HiRes imaging system onboard the Clementine Spacecraft. These mosaics are spatially warped using the sinusoidal equal-area projection at a scale of 20 m/pixel. The geometric control is provided by the 100 m/pixel U.S. Geological Survey (USGS) Clementine Basemap Mosaic compiled from the 750 nm Ultraviolet/Visible Clementine imaging system. Calibration was achieved by removing the image nonuniformity largely caused by the HiRes system's light intensifier. Also provided are offset and scale factors, achieved by a fit of the HiRes data to the corresponding photometrically calibrated UV/Vis basemap that approximately transform the 8-bit HiRes data to photometric units. The mosaics on this CD were compiled from sub-polar data (latitudes 80 degrees South to 80 degrees North; -80 to +80) within the longitude range 0-30 deg E. The mosaics are divided into tiles that cover approximately 1.75 degrees of latitude and span the longitude range of the mosaicked frames. Images from a given orbit are map projected using the orbit's nominal central latitude. This CD contains ancillary data files that support the HiRes mosaic. These files include browse images with UV/Vis context stored in a Joint Photographic Experts Group (JPEG) format, index files ('imgindx.tab' and 'srcindx.tab') that tabulate the contents of the CD, and documentation files. For more information on the contents and organization of the CD volume set refer to the "FILES, DIRECTORIES AND DISK CONTENTS" section of this document. The image files are organized according to NASA's Planetary Data System (PDS) standards. An image file (tile) is organized as a PDS labeled file containing an "image object".
NASA Technical Reports Server (NTRS)
Malin, Michael; Revine, Michael; Boyce, Joseph M. (Technical Monitor)
1998-01-01
This compact disk (CD) is part of the Malin Space Science Systems (MSSS) effort to mosaic Clementine I high resolution (HiRes) camera lunar images. These mosaics were developed through calibration and semi-automated registration against the recently released geometrically and photometrically controlled Ultraviolet/Visible (UV/Vis) Basemap Mosaic, which is available through the PDS, as CD-ROM volumes CL_3001-3015. The HiRes mosaics are compiled from non-uniformity corrected, 750 nanometer ("D") filter high resolution observations from the HiRes imaging system onboard the Clementine Spacecraft. These mosaics are spatially warped using the sinusoidal equal-area projection at a scale of 20 m/pixel. The geometric control is provided by the 100 m/pixel U. S. Geological Survey (USGS) Clementine Basemap Mosaic compiled from the 750 nm Ultraviolet/Visible Clementine imaging system. Calibration was achieved by removing the image nonuniformity largely caused by the HiRes system's light intensifier. Also provided are offset and scale factors, achieved by a fit of the HiRes data to the corresponding photometrically calibrated UV/Vis basemap that approximately transform the 8-bit HiRes data to photometric units. The mosaics on this CD were compiled from sub-polar data (latitudes 80 degrees South to 80 degrees North; -80 to +80) within the longitude range 0-30 deg E. The mosaics are divided into tiles that cover approximately 1.75 degrees of latitude and span the longitude range of the mosaicked frames. Images from a given orbit are map projected using the orbit's nominal central latitude. This CD contains ancillary data files that support the HiRes mosaic. These files include browse images with UV/Vis context stored in a Joint Photographic Experts Group (JPEG) format, index files ('imgindx.tab' and 'srcindx.tab') that tabulate the contents of the CD, and documentation files. For more information on the contents and organization of the CD volume set refer to the "FILES, DIRECTORIES AND DISK CONTENTS" section of this document. The image files are organized according to NASA's Planetary Data System (PDS) standards. An image file (tile) is organized as a PDS labeled file containing an "image object".
NASA Technical Reports Server (NTRS)
Malin, Michael; Revine, Michael; Boyce, Joseph M. (Technical Monitor)
1998-01-01
This compact disk (CD) is part of the Malin Space Science Systems (MSSS) effort to mosaic Clementine I high resolution (HiRes) camera lunar images. These mosaics were developed through calibration and semi-automated registration against the recently released geometrically and photometrically controlled Ultraviolet/Visible (UV/Vis) Basemap Mosaic, which is available through the PDS, as CD-ROM volumes CL_3001-3015. The HiRes mosaics are compiled from non-uniformity corrected, 750 nanometer ("D") filter high resolution observations from the HiRes imaging system onboard the Clementine Spacecraft. These mosaics are spatially warped using the sinusoidal equal-area projection at a scale of 20 m/pixel. The geometric control is provided by the 100 m/pixel U.S. Geological Survey (USGS) Clementine Basemap Mosaic compiled from the 750 nm Ultraviolet/Visible Clementine imaging system. Calibration was achieved by removing the image nonuniformity largely caused by the HiRes system's light intensifier. Also provided are offset and scale factors, achieved by a fit of the HiRes data to the corresponding photometrically calibrated UV/Vis basemap that approximately transform the 8-bit HiRes data to photometric units. The mosaics on this CD were compiled from sub-polar data (latitudes 80 degrees South to 80 degrees North; -80 to +80) within the longitude range 0-30 deg E. The mosaics are divided into tiles that cover approximately 1.75 degrees of latitude and span the longitude range of the mosaicked frames. Images from a given orbit are map projected using the orbit's nominal central latitude. This CD contains ancillary data files that support the HiRes mosaic. These files include browse images with UV/Vis context stored in a Joint Photographic Experts Group (JPEG) format, index files ('imgindx.tab' and 'srcindx.tab') that tabulate the contents of the CD, and documentation files. For more information on the contents and organization of the CD volume set refer to the "FILES, DIRECTORIES AND DISK CONTENTS" section of this document. The image files are organized according to NASA's Planetary Data System (PDS) standards. An image file (tile) is organized as a PDS labeled file containing an "image object".
NASA Technical Reports Server (NTRS)
Malin, Michael; Revine, Michael; Boyce, Joseph M. (Technical Monitor)
1998-01-01
This compact disk (CD) is part of the Malin Space Science Systems (MSSS) effort to mosaic Clementine I high resolution (HiRes) camera lunar images. These mosaics were developed through calibration and semi-automated registration against the recently released geometrically and photometrically controlled Ultraviolet/Visible (UV/Vis) Basemap Mosaic, which is available through the PDS, as CD-ROM volumes CL_3001-3015. The HiRes mosaics are compiled from non-uniformity corrected, 750 nanometer ("D") filter high resolution observations from the HiRes imaging system onboard the Clementine Spacecraft. These mosaics are spatially warped using the sinusoidal equal-area projection at a scale of 20 m/pixel. The geometric control is provided by the 100 m/pixel U. S. Geological Survey (USGS) Clementine Basemap Mosaic compiled from the 750 nm Ultraviolet/Visible Clementine imaging system. Calibration was achieved by removing the image nonuniformity largely caused by the HiRes system's light intensifier. Also provided are offset and scale factors, achieved by a fit of the HiRes data to the corresponding photometrically calibrated UV/Vis basemap that approximately transform the 8-bit HiRes data to photometric units. The mosaics on this CD were compiled from sub-polar data (latitudes 80 degrees South to 80 degrees North; -80 to +80) within the longitude range 0-30 deg E. The mosaics are divided into tiles that cover approximately 1.75 degrees of latitude and span the longitude range of the mosaicked frames. Images from a given orbit are map projected using the orbit's nominal central latitude. This CD contains ancillary data files that support the HiRes mosaic. These files include browse images with UV/Vis context stored in a Joint Photographic Experts Group (JPEG) format, index files ('imgindx.tab' and 'srcindx.tab') that tabulate the contents of the CD, and documentation files. For more information on the contents and organization of the CD volume set refer to the "FILES, DIRECTORIES AND DISK CONTENTS" section of this document. The image files are organized according to NASA's Planetary Data System (PDS) standards. An image file (tile) is organized as a PDS labeled file containing an "image object".
NASA Technical Reports Server (NTRS)
Malin, Michael; Revine, Michael; Boyce, Joseph M. (Technical Monitor)
1998-01-01
This compact disk (CD) is part of the Malin Space Science Systems (MSSS) effort to mosaic Clementine I high resolution (HiRes) camera lunar images. These mosaics were developed through calibration and semi-automated registration against the recently released geometrically and photometrically controlled Ultraviolet/Visible (UV/Vis) Basemap Mosaic, which is available through the PDS, as CD-ROM volumes CL_3001-3015. The HiRes mosaics are compiled from non-uniformity corrected, 750 nanometer ("D") filter high resolution observations from the HiRes imaging system onboard the Clementine Spacecraft. These mosaics are spatially warped using the sinusoidal equal-area projection at a scale of 20 m/pixel. The geometric control is provided by the 100 m/pixel U.S. Geological Survey (USGS) Clementine Basemap Mosaic compiled from the 750 nm Ultraviolet/Visible Clementine imaging system. Calibration was achieved by removing the image nonuniformity largely caused by the HiRes system's light intensifier. Also provided are offset and scale factors, achieved by a fit of the HiRes data to the corresponding photometrically calibrated UV/Vis basemap that approximately transform the 8-bit HiRes data to photometric units. The mosaics on this CD were compiled from sub-polar data (latitudes 80 degrees South to 80 degrees North; -80 to +80) within the longitude range 0-30 deg E. The mosaics are divided into tiles that cover approximately 1.75 degrees of latitude and span the longitude range of the mosaicked frames. Images from a given orbit are map projected using the orbit's nominal central latitude. This CD contains ancillary data files that support the HiRes mosaic. These files include browse images with UV/Vis context stored in a Joint Photographic Experts Group (JPEG) format, index files ('imgindx.tab' and 'srcindx.tab') that tabulate the contents of the CD, and documentation files. For more information on the contents and organization of the CD volume set refer to the "FILES, DIRECTORIES AND DISK CONTENTS" section of this document. The image files are organized according to NASA's Planetary Data System (PDS) standards. An image file (tile) is organized as a PDS labeled file containing an "image object".
NASA Technical Reports Server (NTRS)
Malin, Michael; Revine, Michael; Boyce, Joseph M. (Technical Monitor)
1998-01-01
This compact disk (CD) is part of the Malin Space Science Systems (MSSS) effort to mosaic Clementine I high resolution (HiRes) camera lunar images. These mosaics were developed through calibration and semi-automated registration against the recently released geometrically and photometrically controlled Ultraviolet/Visible (UV/Vis) Basemap Mosaic, which is available through the PDS, as CD-ROM volumes CL_3001-3015. The HiRes mosaics are compiled from non-uniformity corrected, 750 nanometer ("D") filter high resolution observations from the HiRes imaging system onboard the Clementine Spacecraft. These mosaics are spatially warped using the sinusoidal equal-area projection at a scale of 20 m/pixel. The geometric control is provided by the 100 m/pixel U.S. Geological Survey (USGS) Clementine Basemap Mosaic compiled from the 750 nm Ultraviolet/Visible Clementine imaging system. Calibration was achieved by removing the image nonuniformity largely caused by the HiRes system's light intensifier. Also provided are offset and scale factors, achieved by a fit of the HiRes data to the corresponding photometrically calibrated UV/Vis basemap that approximately transform the 8-bit HiRes data to photometric units. The mosaics on this CD were compiled from sub-polar data (latitudes 80 degrees South to 80 degrees North; -80 to +80) within the longitude range 0-30 deg E. The mosaics are divided into tiles that cover approximately 1.75 degrees of latitude and span the longitude range of the mosaicked frames. Images from a given orbit are map projected using the orbit's nominal central latitude. This CD contains ancillary data files that support the HiRes mosaic. These files include browse images with UV/Vis context stored in a Joint Photographic Experts Group (JPEG) format, index files ('imgindx.tab' and 'srcindx.tab') that tabulate the contents of the CD, and documentation files. For more information on the contents and organization of the CD volume set refer to the "FILES, DIRECTORIES AND DISK CONTENTS" section of this document. The image files are organized according to NASA's Planetary Data System (PDS) standards. An image file (tile) is organized as a PDS labeled file containing an "image object".
NASA Technical Reports Server (NTRS)
Malin, Michael; Revine, Michael; Boyce, Joseph M. (Technical Monitor)
1998-01-01
This compact disk (CD) is part of the Malin Space Science Systems (MSSS) effort to mosaic Clementine I high resolution (HiRes) camera lunar images. These mosaics were developed through calibration and semi-automated registration against the recently released geometrically and photometrically controlled Ultraviolet/Visible (UV/Vis) Basemap Mosaic, which is available through the PDS, as CD-ROM volumes CL_3001-3015. The HiRes mosaics are compiled from non-uniformity corrected, 750 nanometer ("D") filter high resolution observations from the HiRes imaging system onboard the Clementine Spacecraft. These mosaics are spatially warped using the sinusoidal equal-area projection at a scale of 20 m/pixel. The geometric control is provided by the 100 m/pixel U.S. Geological Survey (USGS) Clementine Basemap Mosaic compiled from the 750 nm Ultraviolet/Visible Clementine imaging system. Calibration was achieved by removing the image nonuniformity largely caused by the HiRes system's light intensifier. Also provided are offset and scale factors, achieved by a fit of the HiRes data to the corresponding photometrically calibrated UV/Vis basemap that approximately transform the 8-bit HiRes data to photometric units. The mosaics on this CD were compiled from sub-polar data (latitudes 80 degrees South to 80 degrees North; -80 to +80) within the longitude range 0-30 deg E. The mosaics are divided into tiles that cover approximately 1.75 degrees of latitude and span the longitude range of the mosaicked frames. Images from a given orbit are map projected using the orbit's nominal central latitude. This CD contains ancillary data files that support the HiRes mosaic. These files include browse images with UV/Vis context stored in a Joint Photographic Experts Group (JPEG) format, index files ('imgindx.tab' and 'srcindx.tab') that tabulate the contents of the CD, and documentation files. For more information on the contents and organization of the CD volume set refer to the "FILES, DIRECTORIES AND DISK CONTENTS" section of this document. The image files are organized according to NASA's Planetary Data System (PDS) standards. An image file (tile) is organized as a PDS labeled file containing an "image object".
Efficient image data distribution and management with application to web caching architectures
NASA Astrophysics Data System (ADS)
Han, Keesook J.; Suter, Bruce W.
2003-03-01
We present compact image data structures and associated packet delivery techniques for effective Web caching architectures. Presently, images on a web page are inefficiently stored, using a single image per file. Our approach is to use clustering to merge similar images into a single file in order to exploit the redundancy between images. Our studies indicate that a 30-50% image data size reduction can be achieved by eliminating the redundancies of color indexes. Attached to this file is new metadata to permit an easy extraction of images. This approach will permit a more efficient use of the cache, since a shorter list of cache references will be required. Packet and transmission delays can be reduced by 50% eliminating redundant TCP/IP headers and connection time. Thus, this innovative paradigm for the elimination of redundancy may provide valuable benefits for optimizing packet delivery in IP networks by reducing latency and minimizing the bandwidth requirements.
Barbier, Paolo; Alimento, Marina; Berna, Giovanni; Celeste, Fabrizio; Gentile, Francesco; Mantero, Antonio; Montericcio, Vincenzo; Muratori, Manuela
2007-05-01
Large files produced by standard compression algorithms slow down spread of digital and tele-echocardiography. We validated echocardiographic video high-grade compression with the new Motion Pictures Expert Groups (MPEG)-4 algorithms with a multicenter study. Seven expert cardiologists blindly scored (5-point scale) 165 uncompressed and compressed 2-dimensional and color Doppler video clips, based on combined diagnostic content and image quality (uncompressed files as references). One digital video and 3 MPEG-4 algorithms (WM9, MV2, and DivX) were used, the latter at 3 compression levels (0%, 35%, and 60%). Compressed file sizes decreased from 12 to 83 MB to 0.03 to 2.3 MB (1:1051-1:26 reduction ratios). Mean SD of differences was 0.81 for intraobserver variability (uncompressed and digital video files). Compared with uncompressed files, only the DivX mean score at 35% (P = .04) and 60% (P = .001) compression was significantly reduced. At subcategory analysis, these differences were still significant for gray-scale and fundamental imaging but not for color or second harmonic tissue imaging. Original image quality, session sequence, compression grade, and bitrate were all independent determinants of mean score. Our study supports use of MPEG-4 algorithms to greatly reduce echocardiographic file sizes, thus facilitating archiving and transmission. Quality evaluation studies should account for the many independent variables that affect image quality grading.
5 CFR 1201.14 - Electronic filing procedures.
Code of Federal Regulations, 2010 CFR
2010-01-01
... (PDF), and image files (files created by scanning). A list of formats allowed can be found at e-Appeal..., or by uploading the supporting documents in the form of one or more PDF files in which each...
Service mix in the hospital outpatient department: implications for Medicare payment reform.
Miller, M E; Sulvetta, M B; Englert, E
1995-01-01
OBJECTIVE. To determine if implementation of a PPS for Medicare hospital outpatient department (HOPD) services will have distributional consequences across hospital types and regions, this analysis assesses variation in service mix and the provision of high-technology services in the HOPD. DATA. HCFA's 1990 claims file for a 5 percent random sample of Medicare beneficiaries using the HOPD was merged, by hospital provider number, with various HCFA hospital characteristic files. STUDY DESIGN. Hospital characteristics examined are urban/rural location, teaching status, disproportionate-share status, and bed size. Two analyses of HOPD services are presented: mix of services provided and the provision of high-technology services. The mix of services is measured by the percentage of services in each of 14 type-of-service categories (e.g., medical visits, advanced imaging services, diagnostic testing services). Technology provision is measured by the percentage of hospitals providing selected high-technology services. FINDINGS/CONCLUSIONS. The findings suggest that the role hospital types play in providing HOPD services warrants consideration in establishing a PPS. HOPDs in major teaching hospitals and hospitals serving a disproportionate share of the poor play an important role in providing routine visits. HOPDs in both major and minor teaching hospitals are important providers of high-technology services. Other findings have implications for the structure of an HOPD PPS as well. First, over half of the services provided in the HOPD are laboratory tests and HOPDs may have limited control over these services since they are often for patients referred from local physician offices. Second, service mix and technology provision vary markedly among regions, suggesting the need for a transition to prospective payment. Third, the organization of service supply in a region may affect service provision in the HOPD suggesting that an HOPD PPS needs to be coordinated with payment policies in competing sites of care (e.g., ambulatory surgical centers). PMID:7721585
Selective document image data compression technique
Fu, C.Y.; Petrich, L.I.
1998-05-19
A method of storing information from filled-in form-documents comprises extracting the unique user information in the foreground from the document form information in the background. The contrast of the pixels is enhanced by a gamma correction on an image array, and then the color value of each of pixel is enhanced. The color pixels lying on edges of an image are converted to black and an adjacent pixel is converted to white. The distance between black pixels and other pixels in the array is determined, and a filled-edge array of pixels is created. User information is then converted to a two-color format by creating a first two-color image of the scanned image by converting all pixels darker than a threshold color value to black. All the pixels that are lighter than the threshold color value to white. Then a second two-color image of the filled-edge file is generated by converting all pixels darker than a second threshold value to black and all pixels lighter than the second threshold color value to white. The first two-color image and the second two-color image are then combined and filtered to smooth the edges of the image. The image may be compressed with a unique Huffman coding table for that image. The image file is also decimated to create a decimated-image file which can later be interpolated back to produce a reconstructed image file using a bilinear interpolation kernel. 10 figs.
Selective document image data compression technique
Fu, Chi-Yung; Petrich, Loren I.
1998-01-01
A method of storing information from filled-in form-documents comprises extracting the unique user information in the foreground from the document form information in the background. The contrast of the pixels is enhanced by a gamma correction on an image array, and then the color value of each of pixel is enhanced. The color pixels lying on edges of an image are converted to black and an adjacent pixel is converted to white. The distance between black pixels and other pixels in the array is determined, and a filled-edge array of pixels is created. User information is then converted to a two-color format by creating a first two-color image of the scanned image by converting all pixels darker than a threshold color value to black. All the pixels that are lighter than the threshold color value to white. Then a second two-color image of the filled-edge file is generated by converting all pixels darker than a second threshold value to black and all pixels lighter than the second threshold color value to white. The first two-color image and the second two-color image are then combined and filtered to smooth the edges of the image. The image may be compressed with a unique Huffman coding table for that image. The image file is also decimated to create a decimated-image file which can later be interpolated back to produce a reconstructed image file using a bilinear interpolation kernel.--(235 words)
Escott, Edward J; Rubinstein, David
2004-01-01
It is often necessary for radiologists to use digital images in presentations and conferences. Most imaging modalities produce images in the Digital Imaging and Communications in Medicine (DICOM) format. The image files tend to be large and thus cannot be directly imported into most presentation software, such as Microsoft PowerPoint; the large files also consume storage space. There are many free programs that allow viewing and processing of these files on a personal computer, including conversion to more common file formats such as the Joint Photographic Experts Group (JPEG) format. Free DICOM image viewing and processing software for computers running on the Microsoft Windows operating system has already been evaluated. However, many people use the Macintosh (Apple Computer) platform, and a number of programs are available for these users. The World Wide Web was searched for free DICOM image viewing or processing software that was designed for the Macintosh platform or is written in Java and is therefore platform independent. The features of these programs and their usability were evaluated. There are many free programs for the Macintosh platform that enable viewing and processing of DICOM images. (c) RSNA, 2004.
42 CFR 37.44 - Approval of radiographic facilities that use digital radiography systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... effective management, safety, and proper performance of chest image acquisition, digitization, processing... digital chest radiographs by submitting to NIOSH digital radiographic image files of a test object (e.g... radiographic image files from six or more sample chest radiographs that are of acceptable quality to one or...
Radel, Robert T; Goodell, Gary G; McClanahan, Scott B; Cohen, Mark E
2006-06-01
Previous studies suggest that digital and film-based radiography are similar for endodontic measurements. This study compared the accuracy and acceptability of measured distances from the tips of size #10 and #15 files to molar root apices in cadaver jaw sections using the newly developed Kodak RVG 6000, and the Schick CDR digital systems to digitized Kodak film. Standardized images were taken of files placed 0.5 to 1.5 mm short of true radiographic lengths. Images were imported into Adobe PhotoShop 7.0, thereby blinding observers who measured distances from files to root apices and assessed images for clarity (acceptability). Repeated measures ANOVA and Tukey-Kramer post hoc tests demonstrated that Kodak RVG 6000 images with enhanced contrast produced significantly less measurement error than unenhanced contrast Schick CDR images (p < 0.05) and significantly higher acceptability ratings than all other systems (all p < 0.002). Among these conditions, the newly developed Kodak RVG 6000 system provided the best overall images.
Creating a classification of image types in the medical literature for visual categorization
NASA Astrophysics Data System (ADS)
Müller, Henning; Kalpathy-Cramer, Jayashree; Demner-Fushman, Dina; Antani, Sameer
2012-02-01
Content-based image retrieval (CBIR) from specialized collections has often been proposed for use in such areas as diagnostic aid, clinical decision support, and teaching. The visual retrieval from broad image collections such as teaching files, the medical literature or web images, by contrast, has not yet reached a high maturity level compared to textual information retrieval. Visual image classification into a relatively small number of classes (20-100) on the other hand, has shown to deliver good results in several benchmarks. It is, however, currently underused as a basic technology for retrieval tasks, for example, to limit the search space. Most classification schemes for medical images are focused on specific areas and consider mainly the medical image types (modalities), imaged anatomy, and view, and merge them into a single descriptor or classification hierarchy. Furthermore, they often ignore other important image types such as biological images, statistical figures, flowcharts, and diagrams that frequently occur in the biomedical literature. Most of the current classifications have also been created for radiology images, which are not the only types to be taken into account. With Open Access becoming increasingly widespread particularly in medicine, images from the biomedical literature are more easily available for use. Visual information from these images and knowledge that an image is of a specific type or medical modality could enrich retrieval. This enrichment is hampered by the lack of a commonly agreed image classification scheme. This paper presents a hierarchy for classification of biomedical illustrations with the goal of using it for visual classification and thus as a basis for retrieval. The proposed hierarchy is based on relevant parts of existing terminologies, such as the IRMA-code (Image Retrieval in Medical Applications), ad hoc classifications and hierarchies used in imageCLEF (Image retrieval task at the Cross-Language Evaluation Forum) and NLM's (National Library of Medicine) OpenI. Furtheron, mappings to NLM's MeSH (Medical Subject Headings), RSNA's RadLex (Radiological Society of North America, Radiology Lexicon), and the IRMA code are also attempted for relevant image types. Advantages derived from such hierarchical classification for medical image retrieval are being evaluated through benchmarks such as imageCLEF, and R&D systems such as NLM's OpenI. The goal is to extend this hierarchy progressively and (through adding image types occurring in the biomedical literature) to have a terminology for visual image classification based on image types distinguishable by visual means and occurring in the medical open access literature.
High-throughput imaging of heterogeneous cell organelles with an X-ray laser (CXIDB ID 25)
Hantke, Max, F.
2014-11-17
Preprocessed detector images that were used for the paper "High-throughput imaging of heterogeneous cell organelles with an X-ray laser". The CXI file contains the entire recorded data - including both hits and blanks. It also includes down-sampled images and LCLS machine parameters. Additionally, the Cheetah configuration file is attached that was used to create the pre-processed data.
A Flipped Writing Classroom: Effects on EFL Learners' Argumentative Essays
ERIC Educational Resources Information Center
Soltanpour, Fatemeh; Valizadeh, Mohammadreza
2018-01-01
According to the literature, flipped teaching is a relatively new pedagogical approach in which the typical activities of classroom lectures followed by homework in common teaching practice are reversed in order, and most often integrated or supplemented with some types of instructional materials, such as instructional videos or PowerPoint files.…
Exploring Podcasting in Heredity and Evolution Teaching
ERIC Educational Resources Information Center
Almeida-Aguiar, Cristina; Carvalho, Ana Amélia
2016-01-01
Podcasts are digital files very popular in several and very distinct areas. In higher education, they have been explored in a multitude of ways mainly to support teaching and learning processes. The study here described focuses the integration of podcasts in Heredity and Evolution, a course from the Biology and Geology Degree Program at University…
Soni, Dileep; Raisingani, Deepak; Mathur, Rachit; Madan, Nidha; Visnoi, Suchita
2016-01-01
To evaluate the incidence of apical crack initiation during canal preparation with stainless steel K-files and hand protaper files (in vitro study). Sixty extracted mandibular premo-lar teeth are randomly selected and embedded in an acrylic tube filled with autopolymerizing resin. A baseline image of the apical surface of each specimen was recorded under a digital microscope (80×). The cervical and middle thirds of all samples were flared with #2 and #1 Gates-Glidden (GG) drills, and a second image was recorded. The teeth were randomly divided into four groups of 15 teeth each according to the file type (hand K-file and hand-protaper) and working length (WL) (instrumented at WL and 1 mm less than WL). Final image after dye penetration and photomicrograph of the apical root surface were digitally recorded. Maximum numbers of cracks were observed with hand protaper files compared with hand K-file at the WL and 1 mm short of WL. Chi-square testing revealed a highly significant effect of WL on crack formation at WL and 1 mm short of WL (p = 0.000). Minimum numbers of cracks at WL and 1 mm short of WL were observed with hand K-file and maximum with hand protaper files. Soni D, Raisingani D, Mathur R, Madan N, Visnoi S. Incidence of Apical Crack Initiation during Canal Preparation using Hand Stainless Steel (K-File) and Hand NiTi (Protaper) Files. Int J Clin Pediatr Dent 2016;9(4):303-307.
Katzman, G L; Morris, D; Lauman, J; Cochella, C; Goede, P; Harnsberger, H R
2001-06-01
To foster a community supported evaluation processes for open-source digital teaching file (DTF) development and maintenance. The mechanisms used to support this process will include standard web browsers, web servers, forum software, and custom additions to the forum software to potentially enable a mediated voting protocol. The web server will also serve as a focal point for beta and release software distribution, which is the desired end-goal of this process. We foresee that www.mdtf.org will provide for widespread distribution of open source DTF software that will include function and interface design decisions from community participation on the website forums.
Bruellmann, Dan; Sander, Steven; Schmidtmann, Irene
2016-05-01
The endodontic working length is commonly determined by electronic apex locators and intraoral periapical radiographs. No algorithms for the automatic detection of endodontic files in dental radiographs have been described in the recent literature. Teeth from the mandibles of pig cadavers were accessed, and digital radiographs of these specimens were obtained using an optical bench. The specimens were then recorded in identical positions and settings after the insertion of endodontic files of known sizes (ISO sizes 10-15). The frequency bands generated by the endodontic files were determined using fast Fourier transforms (FFTs) to convert the resulting images into frequency spectra. The detected frequencies were used to design a pre-segmentation filter, which was programmed using Delphi XE RAD Studio software (Embarcadero Technologies, San Francisco, USA) and tested on 20 radiographs. For performance evaluation purposes, the gauged lengths (measured with a caliper) of visible endodontic files were measured in the native and filtered images. The software was able to segment the endodontic files in both the samples and similar dental radiographs. We observed median length differences of 0.52 mm (SD: 2.76 mm) and 0.46 mm (SD: 2.33 mm) in the native and post-segmentation images, respectively. Pearson's correlation test revealed a significant correlation of 0.915 between the true length and the measured length in the native images; the corresponding correlation for the filtered images was 0.97 (p=0.0001). The algorithm can be used to automatically detect and measure the lengths of endodontic files in digital dental radiographs. Copyright © 2016 Elsevier Ltd. All rights reserved.
Chemopreventive Agent Development | Division of Cancer Prevention
[[{"fid":"174","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"Chemoprevenentive Agent Development Research Group Homepage Logo","field_file_image_title_text[und][0][value]":"Chemoprevenentive Agent Development Research Group Homepage
Cloud Engineering Principles and Technology Enablers for Medical Image Processing-as-a-Service.
Bao, Shunxing; Plassard, Andrew J; Landman, Bennett A; Gokhale, Aniruddha
2017-04-01
Traditional in-house, laboratory-based medical imaging studies use hierarchical data structures (e.g., NFS file stores) or databases (e.g., COINS, XNAT) for storage and retrieval. The resulting performance from these approaches is, however, impeded by standard network switches since they can saturate network bandwidth during transfer from storage to processing nodes for even moderate-sized studies. To that end, a cloud-based "medical image processing-as-a-service" offers promise in utilizing the ecosystem of Apache Hadoop, which is a flexible framework providing distributed, scalable, fault tolerant storage and parallel computational modules, and HBase, which is a NoSQL database built atop Hadoop's distributed file system. Despite this promise, HBase's load distribution strategy of region split and merge is detrimental to the hierarchical organization of imaging data (e.g., project, subject, session, scan, slice). This paper makes two contributions to address these concerns by describing key cloud engineering principles and technology enhancements we made to the Apache Hadoop ecosystem for medical imaging applications. First, we propose a row-key design for HBase, which is a necessary step that is driven by the hierarchical organization of imaging data. Second, we propose a novel data allocation policy within HBase to strongly enforce collocation of hierarchically related imaging data. The proposed enhancements accelerate data processing by minimizing network usage and localizing processing to machines where the data already exist. Moreover, our approach is amenable to the traditional scan, subject, and project-level analysis procedures, and is compatible with standard command line/scriptable image processing software. Experimental results for an illustrative sample of imaging data reveals that our new HBase policy results in a three-fold time improvement in conversion of classic DICOM to NiFTI file formats when compared with the default HBase region split policy, and nearly a six-fold improvement over a commonly available network file system (NFS) approach even for relatively small file sets. Moreover, file access latency is lower than network attached storage.
SU-E-T-327: The Update of a XML Composing Tool for TrueBeam Developer Mode
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yan, Y; Mao, W; Jiang, S
2014-06-01
Purpose: To introduce a major upgrade of a novel XML beam composing tool to scientists and engineers who strive to translate certain capabilities of TrueBeam Developer Mode to future clinical benefits of radiation therapy. Methods: TrueBeam Developer Mode provides the users with a test bed for unconventional plans utilizing certain unique features not accessible at the clinical mode. To access the full set of capabilities, a XML beam definition file accommodating all parameters including kV/MV imaging triggers in the plan can be locally loaded at this mode, however it is difficult and laborious to compose one in a text editor.more » In this study, a stand-along interactive XML beam composing application, TrueBeam TeachMod, was developed on Windows platforms to assist users in making their unique plans in a WYSWYG manner. A conventional plan can be imported in a DICOM RT object as the start of the beam editing process in which trajectories of all axes of a TrueBeam machine can be modified to the intended values at any control point. TeachMod also includes libraries of predefined imaging and treatment procedures to further expedite the process. Results: The TeachMod application is a major of the TeachMod module within DICOManTX. It fully supports TrueBeam 2.0. Trajectories of all axes including all MLC leaves can be graphically rendered and edited as needed. The time for XML beam composing has been reduced to a negligible amount regardless the complexity of the plan. A good understanding of XML language and TrueBeam schema is not required though preferred. Conclusion: Creating XML beams manually in a text editor will be a lengthy error-prone process for sophisticated plans. A XML beam composing tool is highly desirable for R and D activities. It will bridge the gap between scopes of TrueBeam capabilities and their clinical application potentials.« less
Incorporating the APS Catalog of the POSS I and Image Archive in ADS
NASA Technical Reports Server (NTRS)
Humphreys, Roberta M.
1998-01-01
The primary purpose of this contract was to develop the software to both create and access an on-line database of images from digital scans of the Palomar Sky Survey. This required modifying our DBMS (called Star Base) to create an image database from the actual raw pixel data from the scans. The digitized images are processed into a set of coordinate-reference index and pixel files that are stored in run-length files, thus achieving an efficient lossless compression. For efficiency and ease of referencing, each digitized POSS I plate is then divided into 900 subplates. Our custom DBMS maps each query into the corresponding POSS plate(s) and subplate(s). All images from the appropriate subplates are retrieved from disk with byte-offsets taken from the index files. These are assembled on-the-fly into a GIF image file for browser display, and a FITS format image file for retrieval. The FITS images have a pixel size of 0.33 arcseconds. The FITS header contains astrometric and photometric information. This method keeps the disk requirements manageable while allowing for future improvements. When complete, the APS Image Database will contain over 130 Gb of data. A set of web pages query forms are available on-line, as well as an on-line tutorial and documentation. The database is distributed to the Internet by a high-speed SGI server and a high-bandwidth disk system. URL is http://aps.umn.edu/IDB/. The image database software is written in perl and C and has been compiled on SGI computers with MIX5.3. A copy of the written documentation is included and the software is on the accompanying exabyte tape.
The Open Microscopy Environment: open image informatics for the biological sciences
NASA Astrophysics Data System (ADS)
Blackburn, Colin; Allan, Chris; Besson, Sébastien; Burel, Jean-Marie; Carroll, Mark; Ferguson, Richard K.; Flynn, Helen; Gault, David; Gillen, Kenneth; Leigh, Roger; Leo, Simone; Li, Simon; Lindner, Dominik; Linkert, Melissa; Moore, Josh; Moore, William J.; Ramalingam, Balaji; Rozbicki, Emil; Rustici, Gabriella; Tarkowska, Aleksandra; Walczysko, Petr; Williams, Eleanor; Swedlow, Jason R.
2016-07-01
Despite significant advances in biological imaging and analysis, major informatics challenges remain unsolved: file formats are proprietary, storage and analysis facilities are lacking, as are standards for sharing image data and results. While the open FITS file format is ubiquitous in astronomy, astronomical imaging shares many challenges with biological imaging, including the need to share large image sets using secure, cross-platform APIs, and the need for scalable applications for processing and visualization. The Open Microscopy Environment (OME) is an open-source software framework developed to address these challenges. OME tools include: an open data model for multidimensional imaging (OME Data Model); an open file format (OME-TIFF) and library (Bio-Formats) enabling free access to images (5D+) written in more than 145 formats from many imaging domains, including FITS; and a data management server (OMERO). The Java-based OMERO client-server platform comprises an image metadata store, an image repository, visualization and analysis by remote access, allowing sharing and publishing of image data. OMERO provides a means to manage the data through a multi-platform API. OMERO's model-based architecture has enabled its extension into a range of imaging domains, including light and electron microscopy, high content screening, digital pathology and recently into applications using non-image data from clinical and genomic studies. This is made possible using the Bio-Formats library. The current release includes a single mechanism for accessing image data of all types, regardless of original file format, via Java, C/C++ and Python and a variety of applications and environments (e.g. ImageJ, Matlab and R).
ERIC Educational Resources Information Center
Aaron, Lynn S.; Roche, Catherine M.
2012-01-01
"Cloud computing" refers to the use of computing resources on the Internet instead of on individual personal computers. The field is expanding and has significant potential value for educators. This is discussed with a focus on four main functions: file storage, file synchronization, document creation, and collaboration--each of which has…
Building a Steganography Program Including How to Load, Process, and Save JPEG and PNG Files in Java
ERIC Educational Resources Information Center
Courtney, Mary F.; Stix, Allen
2006-01-01
Instructors teaching beginning programming classes are often interested in exercises that involve processing photographs (i.e., files stored as .jpeg). They may wish to offer activities such as color inversion, the color manipulation effects archived with pixel thresholding, or steganography, all of which Stevenson et al. [4] assert are sought by…
ERIC Educational Resources Information Center
Mobbs, Robin
2016-01-01
While on the International Space Station, Tim Peake undertook and recorded video files of experiments suitable for physics teaching coordinated by the National Space Academy. This article describes how the video of these experiments was prepared for use with tracking software. The tracking files of the videos are suitable for use by teachers or…
Prostate and Urologic Cancer | Division of Cancer Prevention
[[{"fid":"183","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"Prostate and Urologic Cancer Research Group Homepage Logo","field_file_image_title_text[und][0][value]":"Prostate and Urologic Cancer Research Group Homepage
Surmounting the Effects of Lossy Compression on Steganography
1996-10-01
and can be exploited to export sensitive information. Since images are fre- quently compressed for storage or transmission, effective steganography ... steganography is that which is stored with an accuracy far greater than necessary for the data’s use and display. Image , Postscript, and audio files are...information can be concealed in bitmapped image files with little or no visible degradation of the image [4.]. This process, called steganography , is
Secure Display of Space-Exploration Images
NASA Technical Reports Server (NTRS)
Cheng, Cecilia; Thornhill, Gillian; McAuley, Michael
2006-01-01
Java EDR Display Interface (JEDI) is software for either local display or secure Internet distribution, to authorized clients, of image data acquired from cameras aboard spacecraft engaged in exploration of remote planets. ( EDR signifies experimental data record, which, in effect, signifies image data.) Processed at NASA s Multimission Image Processing Laboratory (MIPL), the data can be from either near-realtime processing streams or stored files. JEDI uses the Java Advanced Imaging application program interface, plus input/output packages that are parts of the Video Image Communication and Retrieval software of the MIPL, to display images. JEDI can be run as either a standalone application program or within a Web browser as a servlet with an applet front end. In either operating mode, JEDI communicates using the HTTP(s) protocol(s). In the Web-browser case, the user must provide a password to gain access. For each user and/or image data type, there is a configuration file, called a "personality file," containing parameters that control the layout of the displays and the information to be included in them. Once JEDI has accepted the user s password, it processes the requested EDR (provided that user is authorized to receive the specific EDR) to create a display according to the user s personality file.
VizieR Online Data Catalog: HD61005 SPHERE H and Ks images (Olofsson+, 2016)
NASA Astrophysics Data System (ADS)
Olofsson, J.; Samland, M.; Avenhaus, H.; Caceres, C.; Henning, T.; Moor, A.; Milli, J.; Canovas, H.; Quanz, S. P.; Schreiber, M. R.; Augereau, J.-C.; Bayo, A.; Bazzon, A.; Beuzit, J.-L.; Boccaletti, A.; Buenzli, E.; Casassus, S.; Chauvin, G.; Dominik, C.; Desidera, S.; Feldt, M.; Gratton, R.; Janson, M.; Lagrange, A.-M.; Langlois, M.; Lannier, J.; Maire, A.-L.; Mesa, D.; Pinte, C.; Rouan, D.; Salter, G.; Thalmann, C.; Vigan, A.
2016-05-01
The fits files contains the reduced ADI and DPI SPHERE observations used to produce Fig. 1 of the paper. Besides the primary card, the files consists of 6 additional ImageHDU. The first and second one contain the SPHERE IRDIS ADI H band observations and the noise map. The third and fourth contain the SPHERE IRDIS ADI Ks band observations and the corresponding noise map. Finally, the fifth and sixth ImageHDU contain the SPHERE IRDIS DPI H band data as well as the noise map. Each ADI image has 1024x1024 pixels, while the DPI images have 1800x1800 pixels. The header of the primary card contains the pixel sizes for each datasets and the wavelengths of the H and K band observations. (2 data files).
A model for a PC-based, universal-format, multimedia digitization system: moving beyond the scanner.
McEachen, James C; Cusack, Thomas J; McEachen, John C
2003-08-01
Digitizing images for use in case presentations based on hardcopy films, slides, photographs, negatives, books, and videos can present a challenging task. Scanners and digital cameras have become standard tools of the trade. Unfortunately, use of these devices to digitize multiple images in many different media formats can be a time-consuming and in some cases unachievable process. The authors' goal was to create a PC-based solution for digitizing multiple media formats in a timely fashion while maintaining adequate image presentation quality. The authors' PC-based solution makes use of off-the-shelf hardware applications to include a digital document camera (DDC), VHS video player, and video-editing kit. With the assistance of five staff radiologists, the authors examined the quality of multiple image types digitized with this equipment. The authors also quantified the speed of digitization of various types of media using the DDC and video-editing kit. With regard to image quality, the five staff radiologists rated the digitized angiography, CT, and MR images as adequate to excellent for use in teaching files and case presentations. With regard to digitized plain films, the average rating was adequate. As for performance, the authors recognized a 68% improvement in the time required to digitize hardcopy films using the DDC instead of a professional quality scanner. The PC-based solution provides a means for digitizing multiple images from many different types of media in a timely fashion while maintaining adequate image presentation quality.
Morgan, Karen L. M.; Krohn, M. Dennis
2016-02-17
Table 1 provides detailed information about the GPS location, image name, date, and time for each of the 2,688 photographs that were taken along with links to each photograph.In addition to the photographs, a Google Earth Keyhole Markup Language (KML) file is provided and can be used to view the images by clicking on the marker and then clicking on either the thumbnail or the link above the thumbnail. The KML also shows the track of Hurricane Irene. The KML files were created using the photographic navigation files. These KML file(s) can be found in the kml folder.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perl, J; Villagomez-Bernabe, B; Currell, F
2015-06-15
Purpose: The stochastic nature of the subatomic world presents a challenge for physics education. Even experienced physicists can be amazed at the varied behavior of electrons, x-rays, protons, neutrons, ions and the any short-lived particles that make up the overall behavior of our accelerators, brachytherapy sources and medical imaging systems. The all-particle Monte Carlo particle transport tool, TOPAS Tool for Particle Simulation, originally developed for proton therapy research, has been repurposed into a physics teaching tool, TOPAS-edu. Methods: TOPAS-edu students set up simulated particle sources, collimators, scatterers, imagers and scoring setups by writing simple ASCII files (in the TOPAS Parametermore » Control System format). Students visualize geometry setups and particle trajectories in a variety of modes from OpenGL graphics to VRML 3D viewers to gif and PostScript image files. Results written to simple comma separated values files are imported by the student into their preferred data analysis tool. Students can vary random seeds or adjust parameters of physics processes to better understand the stochastic nature of subatomic physics. Results: TOPAS-edu has been successfully deployed as the centerpiece of a physics course for master’s students at Queen’s University Belfast. Tutorials developed there takes students through a step by step course on the basics of particle transport and interaction, scattering, Bremsstrahlung, etc. At each step in the course, students build simulated experimental setups and then analyze the simulated results. Lessons build one upon another so that a student might end up with a full simulation of a medical accelerator, a water-phantom or an imager. Conclusion: TOPAS-edu was well received by students. A second application of TOPAS-edu is currently in development at Zurich University of Applied Sciences, Switzerland. It is our eventual goal to make TOPAS-edu available free of charge to any non-profit organization, along with associated tutorial materials developed by the TOPAS-edu community. Work supported in part by the U.S. Department of Energy under contract number DE-AC02-76SF00515. B. Villagomez-Bernabe is supported by CONACyT (Mexican Council for Science and Technology) project 231844.« less
Raisingani, Deepak; Mathur, Rachit; Madan, Nidha; Visnoi, Suchita
2016-01-01
Aim To evaluate the incidence of apical crack initiation during canal preparation with stainless steel K-files and hand protaper files (in vitro study). Materials and methods Sixty extracted mandibular premo-lar teeth are randomly selected and embedded in an acrylic tube filled with autopolymerizing resin. A baseline image of the apical surface of each specimen was recorded under a digital microscope (80×). The cervical and middle thirds of all samples were flared with #2 and #1 Gates-Glidden (GG) drills, and a second image was recorded. The teeth were randomly divided into four groups of 15 teeth each according to the file type (hand K-file and hand-protaper) and working length (WL) (instrumented at WL and 1 mm less than WL). Final image after dye penetration and photomicrograph of the apical root surface were digitally recorded. Results Maximum numbers of cracks were observed with hand protaper files compared with hand K-file at the WL and 1 mm short of WL. Chi-square testing revealed a highly significant effect of WL on crack formation at WL and 1 mm short of WL (p = 0.000). Conclusion Minimum numbers of cracks at WL and 1 mm short of WL were observed with hand K-file and maximum with hand protaper files. How to cite this article Soni D, Raisingani D, Mathur R, Madan N, Visnoi S. Incidence of Apical Crack Initiation during Canal Preparation using Hand Stainless Steel (K-File) and Hand NiTi (Protaper) Files. Int J Clin Pediatr Dent 2016;9(4):303-307. PMID:28127160
ERIC Educational Resources Information Center
Treleven, Mark D.; Penlesky, Richard J.; Callarman, Thomas E.; Watts, Charles A.; Bragg, Daniel J.
2012-01-01
This paper presents the innovation of sharing animated PowerPoint presentations used in teaching operations and supply chain management techniques and concepts through an international electronic exchange. The plan for the exchange is presented and discussed. The potential benefits to faculty and students of using PowerPoint animations in…
Attu: North American Battleground of World War II. Teaching with Historic Places.
ERIC Educational Resources Information Center
Metcalf, Fay
This lesson from the "Teaching with Historic Places" series is based closely on the National Register of Historic Places nomination file on Attu Battlefield and U.S. Army and Navy Airfields on Attu, a National Historic landmark. Materials for students include: (1) a reading outlining the Japanese occupation and U.S. recapture of Attu;…
Writing Across the Curriculum: Writing Assignments. TWI Resource File.
ERIC Educational Resources Information Center
Rish, Shirley; Lapidus-Saltz, Wendy
1982-01-01
THE FOLLOWING IS THE FULL TEXT OF THIS DOCUMENT: If you teach a composition class which is affiliated with a subject-matter course, one of the following assignments may be appropriate for your students. If, on the other hand, you teach a traditionallly constituted composition class, you might give your students the entire list with instructions to…
Toward a standard reference database for computer-aided mammography
NASA Astrophysics Data System (ADS)
Oliveira, Júlia E. E.; Gueld, Mark O.; de A. Araújo, Arnaldo; Ott, Bastian; Deserno, Thomas M.
2008-03-01
Because of the lack of mammography databases with a large amount of codified images and identified characteristics like pathology, type of breast tissue, and abnormality, there is a problem for the development of robust systems for computer-aided diagnosis. Integrated to the Image Retrieval in Medical Applications (IRMA) project, we present an available mammography database developed from the union of: The Mammographic Image Analysis Society Digital Mammogram Database (MIAS), The Digital Database for Screening Mammography (DDSM), the Lawrence Livermore National Laboratory (LLNL), and routine images from the Rheinisch-Westfälische Technische Hochschule (RWTH) Aachen. Using the IRMA code, standardized coding of tissue type, tumor staging, and lesion description was developed according to the American College of Radiology (ACR) tissue codes and the ACR breast imaging reporting and data system (BI-RADS). The import was done automatically using scripts for image download, file format conversion, file name, web page and information file browsing. Disregarding the resolution, this resulted in a total of 10,509 reference images, and 6,767 images are associated with an IRMA contour information feature file. In accordance to the respective license agreements, the database will be made freely available for research purposes, and may be used for image based evaluation campaigns such as the Cross Language Evaluation Forum (CLEF). We have also shown that it can be extended easily with further cases imported from a picture archiving and communication system (PACS).
Teresa E. Jordan
2015-09-30
This submission contains information used to compute the risk factors for the GPFA-AB project (DE-EE0006726). The risk factors are natural reservoir quality, thermal resource quality, potential for induced seismicity, and utilization. The methods used to combine the risk factors included taking the product, sum, and minimum of the four risk factors. The files are divided into images, rasters, shapefiles, and supporting information. The image files show what the raster and shapefiles should look like. The raster files contain the input risk factors, calculation of the scaled risk factors, and calculation of the combined risk factors. The shapefiles include definition of the fairways, definition of the US Census Places, the center of the raster cells, and locations of industries. Supporting information contains details of the calculations or processing used in generating the files. An image of the raster will have the same name except *.png as the file ending instead of *.tif. Images with “fairways” or “industries” added to the name are composed of a raster with the relevant shapefile added. The file About_GPFA-AB_Phase1RiskAnalysisTask5DataUpload.pdf contains information the citation, special use considerations, authorship, etc. More details on each file are given in the spreadsheet “list_of_contents.csv” in the folder “SupportingInfo”. Code used to calculate values is available at https://github.com/calvinwhealton/geothermal_pfa under the folder “combining_metrics”.
GPFA-AB_Phase1RiskAnalysisTask5DataUpload
Teresa E. Jordan
2015-09-30
This submission contains information used to compute the risk factors for the GPFA-AB project (DE-EE0006726). The risk factors are natural reservoir quality, thermal resource quality, potential for induced seismicity, and utilization. The methods used to combine the risk factors included taking the product, sum, and minimum of the four risk factors. The files are divided into images, rasters, shapefiles, and supporting information. The image files show what the raster and shapefiles should look like. The raster files contain the input risk factors, calculation of the scaled risk factors, and calculation of the combined risk factors. The shapefiles include definition of the fairways, definition of the US Census Places, the center of the raster cells, and locations of industries. Supporting information contains details of the calculations or processing used in generating the files. An image of the raster will have the same name except *.png as the file ending instead of *.tif. Images with “fairways” or “industries” added to the name are composed of a raster with the relevant shapefile added. The file About_GPFA-AB_Phase1RiskAnalysisTask5DataUpload.pdf contains information the citation, special use considerations, authorship, etc. More details on each file are given in the spreadsheet “list_of_contents.csv” in the folder “SupportingInfo”. Code used to calculate values is available at https://github.com/calvinwhealton/geothermal_pfa under the folder “combining_metrics”.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garlick, J.
2007-08-23
The nfsroot RPM is installed into a root image which is served to clientsread-only. When the client boots, the union file systme (aufs) is sued to combine this read-only NFS root file systme with a tmpfs file system, yielding a read-write file systme where changes go to the tmpfs.
Developing students’ ideas about lens imaging: teaching experiments with an image-based approach
NASA Astrophysics Data System (ADS)
Grusche, Sascha
2017-07-01
Lens imaging is a classic topic in physics education. To guide students from their holistic viewpoint to the scientists’ analytic viewpoint, an image-based approach to lens imaging has recently been proposed. To study the effect of the image-based approach on undergraduate students’ ideas, teaching experiments are performed and evaluated using qualitative content analysis. Some of the students’ ideas have not been reported before, namely those related to blurry lens images, and those developed by the proposed teaching approach. To describe learning pathways systematically, a conception-versus-time coordinate system is introduced, specifying how teaching actions help students advance toward a scientific understanding.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-20
... SECURITIES AND EXCHANGE COMMISSION [File No. 500-1] In the Matter of the Enlightened Gourmet, Inc., Eternal Image, Inc., NMT Medical, Inc., and Wits Basin Precious Minerals, Inc.; Order of Suspension of... securities of Eternal Image, Inc. because it has not filed any periodic reports since the period ended...
ERIC Educational Resources Information Center
Rossi, Sergio; Benaglia, Maurizio; Brenna, Davide; Porta, Riccardo; Orlandi, Manuel
2015-01-01
A simple procedure to convert protein data bank files (.pdb) into a stereolithography file (.stl) using VMD software (Virtual Molecular Dynamic) is reported. This tutorial allows generating, with a very simple protocol, three-dimensional customized structures that can be printed by a low-cost 3D-printer, and used for teaching chemical education…
Getting Started with AppleWorks Data Base. First Edition.
ERIC Educational Resources Information Center
Schlenker, Richard M.
This manual is a hands-on teaching tool for beginning users of the AppleWorks database software. It was developed to allow Apple IIGS users who are generally familiar with their machine and its peripherals to build a simple AppleWorks database file using version 2.0 or 2.1 of the program, and to store, print, and manipulate the file. The materials…
Educational Aspects of the CONCAM Sky Monitoring Project
NASA Astrophysics Data System (ADS)
Nemiroff, R. J.; Rafert, J. B.; Ftaclas, C.; Pereira, W. E.; Perez-Ramirez, D.
2000-12-01
We have built a prototype CONtinuous CAMera (CONCAM) that mates a fisheye lens to a CCD camera run by a laptop computer. Presently, one CONCAM is deployed at Kitt Peak National Observatory and another is being set up on Mauna Kea in Hawaii. CONCAMs can detect stars of visual magnitude 6 near the image center in a two-minute exposure. CONCAMs are weather-proof, take continuous data from 2 π steradians on the sky, are programmable over the internet, create data files downloadable over the internet, are small enough to fit inside a briefcase, and cost under \\$10 K. . Images archived at http://concam.net can be used to teach many introductory concepts. These include: the rotation of the Earth, the relative location and phase of the Moon, the location and relative motion of planets, the location of the Galactic plane, the motion of Earth satellites, the location and motion of comets, the motion of meteors, the radiant of a meteor shower, the relative locations of interesting stars, and the relative brightness changes of highly variable stars. Concam.net is not meant to replace first hand student observations of the sky, but rather to complement them with classroom-accessible actual-sky-image examples.
Klett, T.R.; Le, P.A.
2007-01-01
This chapter describes data used in support of the process being applied by the U.S. Geological Survey (USGS) National Oil and Gas Assessment (NOGA) project. Digital tabular data used in this report and archival data that permit the user to perform further analyses are available elsewhere on this CD-ROM. Computers and software may import the data without transcription from the Portable Document Format files (.pdf files) of the text by the reader. Graphical images are provided as .pdf files and tabular data are provided in a raw form as tab-delimited text files (.tab files) because of the number and variety of platforms and software available.
Mapping DICOM to OpenDocument format
NASA Astrophysics Data System (ADS)
Yu, Cong; Yao, Zhihong
2009-02-01
In order to enhance the readability, extensibility and sharing of DICOM files, we have introduced XML into DICOM file system (SPIE Volume 5748)[1] and the multilayer tree structure into DICOM (SPIE Volume 6145)[2]. In this paper, we proposed mapping DICOM to ODF(OpenDocument Format), for it is also based on XML. As a result, the new format realizes the separation of content(including text content and image) and display style. Meanwhile, since OpenDocument files take the format of a ZIP compressed archive, the new kind of DICOM files can benefit from ZIP's lossless compression to reduce file size. Moreover, this open format can also guarantee long-term access to data without legal or technical barriers, making medical images accessible to various fields.
Liu, Rui; Kaiwar, Anjali; Shemesh, Hagay; Wesselink, Paul R; Hou, Benxiang; Wu, Min-Kai
2013-01-01
The aim of this study was to compare the incidence of apical root cracks and dentinal detachments after canal preparation with hand and rotary files at different instrumentation lengths. Two hundred forty mandibular incisors were mounted in resin blocks with simulated periodontal ligaments, and the apex was exposed. The root canals were instrumented with rotary and hand files, namely K3, ProTaper, and nickel-titanium Flex K files to the major apical foramen (AF), short AF, or beyond AF. Digital images of the apical surface of every tooth were taken during the apical enlargement at each file change. Development of dentinal defects was determined by comparing these images with the baseline image. Multinomial logistic regression test was performed to identify influencing factors. Apical crack developed in 1 of 80 teeth (1.3%) with hand files and 31 of 160 teeth (19.4%) with rotary files. Apical dentinal detachment developed in 2 of 80 teeth (2.5%) with hand files and 35 of 160 teeth (21.9%) with rotary files. Instrumentation with rotary files terminated 2 mm short of AF and did not cause any cracks. Significantly less cracks and detachments occurred when instrumentation with rotary files was terminated short of AF, as compared with that terminated at or beyond AF (P < .05). The AF deviated from the anatomic apex in 128 of 240 teeth (53%). Significantly more apical dentinal detachments appeared in teeth with a deviated AF (P = .033). Rotary instruments caused more dentinal defects than hand instruments; instrumentation short of AF reduced the risk of dentinal defects. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Cloud Engineering Principles and Technology Enablers for Medical Image Processing-as-a-Service
Bao, Shunxing; Plassard, Andrew J.; Landman, Bennett A.; Gokhale, Aniruddha
2017-01-01
Traditional in-house, laboratory-based medical imaging studies use hierarchical data structures (e.g., NFS file stores) or databases (e.g., COINS, XNAT) for storage and retrieval. The resulting performance from these approaches is, however, impeded by standard network switches since they can saturate network bandwidth during transfer from storage to processing nodes for even moderate-sized studies. To that end, a cloud-based “medical image processing-as-a-service” offers promise in utilizing the ecosystem of Apache Hadoop, which is a flexible framework providing distributed, scalable, fault tolerant storage and parallel computational modules, and HBase, which is a NoSQL database built atop Hadoop’s distributed file system. Despite this promise, HBase’s load distribution strategy of region split and merge is detrimental to the hierarchical organization of imaging data (e.g., project, subject, session, scan, slice). This paper makes two contributions to address these concerns by describing key cloud engineering principles and technology enhancements we made to the Apache Hadoop ecosystem for medical imaging applications. First, we propose a row-key design for HBase, which is a necessary step that is driven by the hierarchical organization of imaging data. Second, we propose a novel data allocation policy within HBase to strongly enforce collocation of hierarchically related imaging data. The proposed enhancements accelerate data processing by minimizing network usage and localizing processing to machines where the data already exist. Moreover, our approach is amenable to the traditional scan, subject, and project-level analysis procedures, and is compatible with standard command line/scriptable image processing software. Experimental results for an illustrative sample of imaging data reveals that our new HBase policy results in a three-fold time improvement in conversion of classic DICOM to NiFTI file formats when compared with the default HBase region split policy, and nearly a six-fold improvement over a commonly available network file system (NFS) approach even for relatively small file sets. Moreover, file access latency is lower than network attached storage. PMID:28884169
Annotated Bibliography of Research in the Teaching of English
ERIC Educational Resources Information Center
Beach, Richard; Brendler, Beth; Dillon, Deborah; Dockter, Jessie; Ernst, Stacy; Frederick, Amy; Galda, Lee; Helman, Lori; Kapoor, Richa; Ngo, Bic; O'Brien, David; Scharber, Cassie; Jorgensen, Karen; Liang, Lauren; Braaksma, Martine; Janssen, Tanja
2010-01-01
This article presents an annotated bibliography of "Research in the Teaching of English" (RTE). The 2010 version of the bibliography involves a major change--the bibliography is available solely as a downloadable pdf file at http://www.ncte.org/journals/rte/issues/v45-2. As the length of the bibliography has grown from 15 pages in 2003 to 88 pages…
Flying across Galaxy Clusters with Google Earth: additional imagery from SDSS co-added data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hao, Jiangang; Annis, James; /Fermilab
2010-10-01
Galaxy clusters are spectacular. We provide a Google Earth compatible imagery for the deep co-added images from the Sloan Digital Sky Survey and make it a tool for examing galaxy clusters. Google Earth (in sky mode) provides a highly interactive environment for visualizing the sky. By encoding the galaxy cluster information into a kml/kmz file, one can use Google Earth as a tool for examining galaxy clusters and fly across them freely. However, the resolution of the images provided by Google Earth is not very high. This is partially because the major imagery google earth used is from Sloan Digitalmore » Sky Survey (SDSS) (SDSS collaboration 2000) and the resolutions have been reduced to speed up the web transferring. To have higher resolution images, you need to add your own images in a way that Google Earth can understand. The SDSS co-added data are the co-addition of {approx}100 scans of images from SDSS stripe 82 (Annis et al. 2010). It provides the deepest images based on SDSS and reach as deep as about redshift 1.0. Based on the co-added images, we created color images in a way as described by Lupton et al. (2004) and convert the color images to Google Earth compatible images using wcs2kml (Brewer et al. 2007). The images are stored at a public server at Fermi National Accelerator Laboratory and can be accessed by the public. To view those images in Google Earth, you need to download a kmz file, which contains the links to the color images, and then open the kmz file with your Google Earth. To meet different needs for resolutions, we provide three kmz files corresponding to low, medium and high resolution images. We recommend the high resolution one as long as you have a broadband Internet connection, though you should choose to download any of them, depending on your own needs and Internet speed. After you open the downloaded kmz file with Google Earth (in sky mode), it takes about 5 minutes (depending on your Internet connection and the resolution of images you want) to get some initial images loaded. Then, additional images corresponding to the region you are browsing will be loaded automatically. So far, you have access to all the co-added images. But you still do not have the galaxy cluster position information to look at. In order to see the galaxy clusters, you need to download another kmz file that tell Google Earth where to find the galaxy clusters in the co-added data region. We provide a kmz file for a few galaxy clusters in the stripe 82 region and you can download and open it with Google Earth. In the SDSS co-added region (stripe 82 region), the imagery from Google Earth itself is from the Digitized Sky Survey (2007), which is in very poor quality. In Figure1 and Figure2, we show screenshots of a cluster with and without the new co-added imagery in Google Earth. Much more details have been revealed with the deep images.« less
SEGY to ASCII Conversion and Plotting Program 2.0
Goldman, Mark R.
2005-01-01
INTRODUCTION SEGY has long been a standard format for storing seismic data and header information. Almost every seismic processing package can read and write seismic data in SEGY format. In the data processing world, however, ASCII format is the 'universal' standard format. Very few general-purpose plotting or computation programs will accept data in SEGY format. The software presented in this report, referred to as SEGY to ASCII (SAC), converts seismic data written in SEGY format (Barry et al., 1975) to an ASCII data file, and then creates a postscript file of the seismic data using a general plotting package (GMT, Wessel and Smith, 1995). The resulting postscript file may be plotted by any standard postscript plotting program. There are two versions of SAC: one version for plotting a SEGY file that contains a single gather, such as a stacked CDP or migrated section, and a second version for plotting multiple gathers from a SEGY file containing more than one gather, such as a collection of shot gathers. Note that if a SEGY file has multiple gathers, then each gather must have the same number of traces per gather, and each trace must have the same sample interval and number of samples per trace. SAC will read several common standards of SEGY data, including SEGY files with sample values written in either IBM or IEEE floating-point format. In addition, utility programs are present to convert non-standard Seismic Unix (.sux) SEGY files and PASSCAL (.rsy) SEGY files to standard SEGY files. SAC allows complete user control over all plotting parameters including label size and font, tick mark intervals, trace scaling, and the inclusion of a title and descriptive text. SAC shell scripts create a postscript image of the seismic data in vector rather than bitmap format, using GMT's pswiggle command. Although this can produce a very large postscript file, the image quality is generally superior to that of a bitmap image, and commercial programs such as Adobe Illustrator? can manipulate the image more efficiently.
36 CFR 1237.28 - What special concerns apply to digital photographs?
Code of Federal Regulations, 2012 CFR
2012-07-01
... defects, evaluate the accuracy of finding aids, and verify file header information and file name integrity... sampling methods or more comprehensive verification systems (e.g., checksum programs), to evaluate image.... For permanent or unscheduled images descriptive elements must include: (1) An identification number...
36 CFR § 1237.28 - What special concerns apply to digital photographs?
Code of Federal Regulations, 2013 CFR
2013-07-01
... defects, evaluate the accuracy of finding aids, and verify file header information and file name integrity... sampling methods or more comprehensive verification systems (e.g., checksum programs), to evaluate image.... For permanent or unscheduled images descriptive elements must include: (1) An identification number...
36 CFR 1237.28 - What special concerns apply to digital photographs?
Code of Federal Regulations, 2014 CFR
2014-07-01
... defects, evaluate the accuracy of finding aids, and verify file header information and file name integrity... sampling methods or more comprehensive verification systems (e.g., checksum programs), to evaluate image.... For permanent or unscheduled images descriptive elements must include: (1) An identification number...
36 CFR 1237.28 - What special concerns apply to digital photographs?
Code of Federal Regulations, 2010 CFR
2010-07-01
... defects, evaluate the accuracy of finding aids, and verify file header information and file name integrity... sampling methods or more comprehensive verification systems (e.g., checksum programs), to evaluate image.... For permanent or unscheduled images descriptive elements must include: (1) An identification number...
36 CFR 1237.28 - What special concerns apply to digital photographs?
Code of Federal Regulations, 2011 CFR
2011-07-01
... defects, evaluate the accuracy of finding aids, and verify file header information and file name integrity... sampling methods or more comprehensive verification systems (e.g., checksum programs), to evaluate image.... For permanent or unscheduled images descriptive elements must include: (1) An identification number...
Knowledge representation for fuzzy inference aided medical image interpretation.
Gal, Norbert; Stoicu-Tivadar, Vasile
2012-01-01
Knowledge defines how an automated system transforms data into information. This paper suggests a representation method of medical imaging knowledge using fuzzy inference systems coded in XML files. The imaging knowledge incorporates features of the investigated objects in linguistic form and inference rules that can transform the linguistic data into information about a possible diagnosis. A fuzzy inference system is used to model the vagueness of the linguistic medical imaging terms. XML files are used to facilitate easy manipulation and deployment of the knowledge into the imaging software. Preliminary results are presented.
Application of whole slide image markup and annotation for pathologist knowledge capture.
Campbell, Walter S; Foster, Kirk W; Hinrichs, Steven H
2013-01-01
The ability to transfer image markup and annotation data from one scanned image of a slide to a newly acquired image of the same slide within a single vendor platform was investigated. The goal was to study the ability to use image markup and annotation data files as a mechanism to capture and retain pathologist knowledge without retaining the entire whole slide image (WSI) file. Accepted mathematical principles were investigated as a method to overcome variations in scans of the same glass slide and to accurately associate image markup and annotation data across different WSI of the same glass slide. Trilateration was used to link fixed points within the image and slide to the placement of markups and annotations of the image in a metadata file. Variation in markup and annotation placement between WSI of the same glass slide was reduced from over 80 μ to less than 4 μ in the x-axis and from 17 μ to 6 μ in the y-axis (P < 0.025). This methodology allows for the creation of a highly reproducible image library of histopathology images and interpretations for educational and research use.
Application of whole slide image markup and annotation for pathologist knowledge capture
Campbell, Walter S.; Foster, Kirk W.; Hinrichs, Steven H.
2013-01-01
Objective: The ability to transfer image markup and annotation data from one scanned image of a slide to a newly acquired image of the same slide within a single vendor platform was investigated. The goal was to study the ability to use image markup and annotation data files as a mechanism to capture and retain pathologist knowledge without retaining the entire whole slide image (WSI) file. Methods: Accepted mathematical principles were investigated as a method to overcome variations in scans of the same glass slide and to accurately associate image markup and annotation data across different WSI of the same glass slide. Trilateration was used to link fixed points within the image and slide to the placement of markups and annotations of the image in a metadata file. Results: Variation in markup and annotation placement between WSI of the same glass slide was reduced from over 80 μ to less than 4 μ in the x-axis and from 17 μ to 6 μ in the y-axis (P < 0.025). Conclusion: This methodology allows for the creation of a highly reproducible image library of histopathology images and interpretations for educational and research use. PMID:23599902
The Development and Preliminary Application Ofplant Quarantine Remote Teaching System Inchina
NASA Astrophysics Data System (ADS)
Wu, Zhigang; Li, Zhihong; Yang, Ding; Zhang, Guozhen
With the development of modern information technology, the traditional teaching mode becomes more deficient for the requirement of modern education. Plant Quarantine has been accepted as the common course for the universities of agriculture in China after the entry of WTO. But the teaching resources of this course are not enough especially for most universities with lack base. The characteristic of e-learning is regarded as one way to solve the problem of short teaching resource. PQRTS (Plant Quarantine Remote Teaching System) was designed and developed with JSP (Java Sever Pages), MySQL and Tomcat in this study. The system included many kinds of plant quarantine teaching resources, such as international glossary, regulations and standards, multimedia information of quarantine process and pests, ppt files of teaching, and training exercise. The system prototype implemented the functions of remote learning, querying, management, examination and remote discussion. It could be a tool for teaching, teaching assistance and learning online.
Cartography of irregularly shaped satellites
NASA Technical Reports Server (NTRS)
Batson, R. M.; Edwards, Kathleen
1987-01-01
Irregularly shaped satellites, such as Phobos and Amalthea, do not lend themselves to mapping by conventional methods because mathematical projections of their surfaces fail to convey an accurate visual impression of the landforms, and because large and irregular scale changes make their features difficult to measure on maps. A digital mapping technique has therefore been developed by which maps are compiled from digital topographic and spacecraft image files. The digital file is geometrically transformed as desired for human viewing, either on video screens or on hard copy. Digital files of this kind consist of digital images superimposed on another digital file representing the three-dimensional form of a body.
A Patient Record-Filing System for Family Practice
Levitt, Cheryl
1988-01-01
The efficient storage and easy retrieval of quality records are a central concern of good family practice. Many physicians starting out in practice have difficulty choosing a practical and lasting system for storing their records. Some who have established practices are installing computers in their offices and finding that their filing systems are worn, outdated, and incompatible with computerized systems. This article describes a new filing system installed simultaneously with a new computer system in a family-practice teaching centre. The approach adopted solved all identifiable problems and is applicable in family practices of all sizes.
Likelihood Ratio Test Polarimetric SAR Ship Detection Application
2005-12-01
menu. Under the Matlab menu, the user can export an area of an image to the MatlabTM MAT file format, as well as call RGB image and Pauli...must specify various parameters such as the area of the image to analyze. Export Image Area to MatlabTM (PoIGASP & COASP) Generates a MatlabTM file...represented by the Minister of National Defence, 2005 (0 Sa majest6 la reine, repr(sent(e par le ministre de la Defense nationale, 2005 Abstract This
Cancer Biomarkers | Division of Cancer Prevention
[[{"fid":"175","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"Cancer Biomarkers Research Group Homepage Logo","field_file_image_title_text[und][0][value]":"Cancer Biomarkers Research Group Homepage Logo","field_folder[und]":"15"},"type":"media","attributes":{"alt":"Cancer Biomarkers Research Group Homepage Logo","title":"Cancer
Gastrointestinal and Other Cancers | Division of Cancer Prevention
[[{"fid":"181","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"Gastrointestinal and Other Cancers Research Group Homepage Logo","field_file_image_title_text[und][0][value]":"Gastrointestinal and Other Cancers Research Group Homepage Logo","field_folder[und]":"15"},"type":"media","attributes":{"alt":"Gastrointestinal and Other
Biometry | Division of Cancer Prevention
[[{"fid":"66","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"Biometry Research Group Homepage Logo","field_file_image_title_text[und][0][value]":"Biometry Research Group Homepage Logo","field_folder[und]":"15"},"type":"media","attributes":{"alt":"Biometry Research Group Homepage Logo","title":"Biometry Research Group Homepage
5 CFR 1201.14 - Electronic filing procedures.
Code of Federal Regulations, 2014 CFR
2014-01-01
...-Appeal Online, in which case service is governed by paragraph (j) of this section, or by non-electronic... (PDF), and image files (files created by scanning). A list of formats allowed can be found at e-Appeal... representatives of the appeals in which they were filed. (j) Service of electronic pleadings and MSPB documents...
5 CFR 1201.14 - Electronic filing procedures.
Code of Federal Regulations, 2013 CFR
2013-01-01
...-Appeal Online, in which case service is governed by paragraph (j) of this section, or by non-electronic... (PDF), and image files (files created by scanning). A list of formats allowed can be found at e-Appeal... representatives of the appeals in which they were filed. (j) Service of electronic pleadings and MSPB documents...
5 CFR 1201.14 - Electronic filing procedures.
Code of Federal Regulations, 2011 CFR
2011-01-01
...-Appeal Online, in which case service is governed by paragraph (j) of this section, or by non-electronic... (PDF), and image files (files created by scanning). A list of formats allowed can be found at e-Appeal... representatives of the appeals in which they were filed. (j) Service of electronic pleadings and MSPB documents...
5 CFR 1201.14 - Electronic filing procedures.
Code of Federal Regulations, 2012 CFR
2012-01-01
...-Appeal Online, in which case service is governed by paragraph (j) of this section, or by non-electronic... (PDF), and image files (files created by scanning). A list of formats allowed can be found at e-Appeal... representatives of the appeals in which they were filed. (j) Service of electronic pleadings and MSPB documents...
Klett, T.R.; Le, P.A.
2006-01-01
This chapter describes data used in support of the process being applied by the U.S. Geological Survey (USGS) National Oil and Gas Assessment (NOGA) project. Digital tabular data used in this report and archival data that permit the user to perform further analyses are available elsewhere on this CD-ROM. Computers and software may import the data without transcription from the Portable Document Format files (.pdf files) of the text by the reader. Because of the number and variety of platforms and software available, graphical images are provided as .pdf files and tabular data are provided in a raw form as tab-delimited text files (.tab files).
Java Library for Input and Output of Image Data and Metadata
NASA Technical Reports Server (NTRS)
Deen, Robert; Levoe, Steven
2003-01-01
A Java-language library supports input and output (I/O) of image data and metadata (label data) in the format of the Video Image Communication and Retrieval (VICAR) image-processing software and in several similar formats, including a subset of the Planetary Data System (PDS) image file format. The library does the following: It provides low-level, direct access layer, enabling an application subprogram to read and write specific image files, lines, or pixels, and manipulate metadata directly. Two coding/decoding subprograms ("codecs" for short) based on the Java Advanced Imaging (JAI) software provide access to VICAR and PDS images in a file-format-independent manner. The VICAR and PDS codecs enable any program that conforms to the specification of the JAI codec to use VICAR or PDS images automatically, without specific knowledge of the VICAR or PDS format. The library also includes Image I/O plugin subprograms for VICAR and PDS formats. Application programs that conform to the Image I/O specification of Java version 1.4 can utilize any image format for which such a plug-in subprogram exists, without specific knowledge of the format itself. Like the aforementioned codecs, the VICAR and PDS Image I/O plug-in subprograms support reading and writing of metadata.
An image-processing software package: UU and Fig for optical metrology applications
NASA Astrophysics Data System (ADS)
Chen, Lujie
2013-06-01
Modern optical metrology applications are largely supported by computational methods, such as phase shifting [1], Fourier Transform [2], digital image correlation [3], camera calibration [4], etc, in which image processing is a critical and indispensable component. While it is not too difficult to obtain a wide variety of image-processing programs from the internet; few are catered for the relatively special area of optical metrology. This paper introduces an image-processing software package: UU (data processing) and Fig (data rendering) that incorporates many useful functions to process optical metrological data. The cross-platform programs UU and Fig are developed based on wxWidgets. At the time of writing, it has been tested on Windows, Linux and Mac OS. The userinterface is designed to offer precise control of the underline processing procedures in a scientific manner. The data input/output mechanism is designed to accommodate diverse file formats and to facilitate the interaction with other independent programs. In terms of robustness, although the software was initially developed for personal use, it is comparably stable and accurate to most of the commercial software of similar nature. In addition to functions for optical metrology, the software package has a rich collection of useful tools in the following areas: real-time image streaming from USB and GigE cameras, computational geometry, computer vision, fitting of data, 3D image processing, vector image processing, precision device control (rotary stage, PZT stage, etc), point cloud to surface reconstruction, volume rendering, batch processing, etc. The software package is currently used in a number of universities for teaching and research.
Brabb, Earl E.; Roberts, Sebastian; Cotton, William R.; Kropp, Alan L.; Wright, Robert H.; Zinn, Erik N.; Digital database by Roberts, Sebastian; Mills, Suzanne K.; Barnes, Jason B.; Marsolek, Joanna E.
2000-01-01
This publication consists of a digital map database on a geohazards web site, http://kaibab.wr.usgs.gov/geohazweb/intro.htm, this text, and 43 digital map images available for downloading at this site. The report is stored as several digital files, in ARC export (uncompressed) format for the database, and Postscript and PDF formats for the map images. Several of the source data layers for the images have already been released in other publications by the USGS and are available for downloading on the Internet. These source layers are not included in this digital database, but rather a reference is given for the web site where the data can be found in digital format. The exported ARC coverages and grids lie in UTM zone 10 projection. The pamphlet, which only describes the content and character of the digital map database, is included as Postscript, PDF, and ASCII text files and is also available on paper as USGS Open-File Report 00-127. The full versatility of the spatial database is realized by importing the ARC export files into ARC/INFO or an equivalent GIS. Other GIS packages, including MapInfo and ARCVIEW, can also use the ARC export files. The Postscript map image can be used for viewing or plotting in computer systems with sufficient capacity, and the considerably smaller PDF image files can be viewed or plotted in full or in part from Adobe ACROBAT software running on Macintosh, PC, or UNIX platforms.
RadSearch: a RIS/PACS integrated query tool
NASA Astrophysics Data System (ADS)
Tsao, Sinchai; Documet, Jorge; Moin, Paymann; Wang, Kevin; Liu, Brent J.
2008-03-01
Radiology Information Systems (RIS) contain a wealth of information that can be used for research, education, and practice management. However, the sheer amount of information available makes querying specific data difficult and time consuming. Previous work has shown that a clinical RIS database and its RIS text reports can be extracted, duplicated and indexed for searches while complying with HIPAA and IRB requirements. This project's intent is to provide a software tool, the RadSearch Toolkit, to allow intelligent indexing and parsing of RIS reports for easy yet powerful searches. In addition, the project aims to seamlessly query and retrieve associated images from the Picture Archiving and Communication System (PACS) in situations where an integrated RIS/PACS is in place - even subselecting individual series, such as in an MRI study. RadSearch's application of simple text parsing techniques to index text-based radiology reports will allow the search engine to quickly return relevant results. This powerful combination will be useful in both private practice and academic settings; administrators can easily obtain complex practice management information such as referral patterns; researchers can conduct retrospective studies with specific, multiple criteria; teaching institutions can quickly and effectively create thorough teaching files.
Breast and Gynecologic Cancer | Division of Cancer Prevention
[[{"fid":"184","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"Breast and Gynecologic Cancer Research Group Homepage Logo","field_file_image_title_text[und][0][value]":"Breast and Gynecologic Cancer Research Group Homepage Logo","field_folder[und]":"15"},"type":"media","attributes":{"alt":"Breast and Gynecologic Cancer Research
Lung and Upper Aerodigestive Cancer | Division of Cancer Prevention
[[{"fid":"180","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"Lung and Upper Aerodigestive Cancer Research Group Homepage Logo","field_file_image_title_text[und][0][value]":"Lung and Upper Aerodigestive Cancer Research Group Homepage Logo","field_folder[und]":"15"},"type":"media","attributes":{"alt":"Lung and Upper Aerodigestive
Visualization and manipulating the image of a formal data structure (FDS)-based database
NASA Astrophysics Data System (ADS)
Verdiesen, Franc; de Hoop, Sylvia; Molenaar, Martien
1994-08-01
A vector map is a terrain representation with a vector-structured geometry. Molenaar formulated an object-oriented formal data structure for 3D single valued vector maps. This FDS is implemented in a database (Oracle). In this study we describe a methodology for visualizing a FDS-based database and manipulating the image. A data set retrieved by querying the database is converted into an import file for a drawing application. An objective of this study is that an end-user can alter and add terrain objects in the image. The drawing application creates an export file, that is compared with the import file. Differences between these files result in updating the database which involves checks on consistency. In this study Autocad is used for visualizing and manipulating the image of the data set. A computer program has been written for the data exchange and conversion between Oracle and Autocad. The data structure of the FDS is compared to the data structure of Autocad and the data of the FDS is converted into the structure of Autocad equal to the FDS.
Image Viewer using Digital Imaging and Communications in Medicine (DICOM)
NASA Astrophysics Data System (ADS)
Baraskar, Trupti N.
2010-11-01
Digital Imaging and Communications in Medicine is a standard for handling, storing, printing, and transmitting information in medical imaging. The National Electrical Manufacturers Association holds the copyright to this standard. It was developed by the DICOM Standards committee. The other image viewers cannot collectively store the image details as well as the patient's information. So the image may get separated from the details, but DICOM file format stores the patient's information and the image details. Main objective is to develop a DICOM image viewer. The image viewer will open .dcm i.e. DICOM image file and also will have additional features such as zoom in, zoom out, black and white inverter, magnifier, blur, B/W inverter, horizontal and vertical flipping, sharpening, contrast, brightness and .gif converter are incorporated.
The PDS-based Data Processing, Archiving and Management Procedures in Chang'e Mission
NASA Astrophysics Data System (ADS)
Zhang, Z. B.; Li, C.; Zhang, H.; Zhang, P.; Chen, W.
2017-12-01
PDS is adopted as standard format of scientific data and foundation of all data-related procedures in Chang'e mission. Unlike the geographically distributed nature of the planetary data system, all procedures of data processing, archiving, management and distribution are proceeded in the headquarter of Ground Research and Application System of Chang'e mission in a centralized manner. The RAW data acquired by the ground stations is transmitted to and processed by data preprocessing subsystem (DPS) for the production of PDS-compliant Level 0 Level 2 data products using established algorithms, with each product file being well described using an attached label, then all products with the same orbit number are put together into a scheduled task for archiving along with a XML archive list file recoding all product files' properties such as file name, file size etc. After receiving the archive request from DPS, data management subsystem (DMS) is provoked to parse the XML list file to validate all the claimed files and their compliance to PDS using a prebuilt data dictionary, then to exact metadata of each data product file from its PDS label and the fields of its normalized filename. Various requirements of data management, retrieving, distribution and application can be well met using the flexible combination of the rich metadata empowered by the PDS. In the forthcoming CE-5 mission, all the design of data structure and procedures will be updated from PDS version 3 used in previous CE-1, CE-2 and CE-3 missions to the new version 4, the main changes would be: 1) a dedicated detached XML label will be used to describe the corresponding scientific data acquired by the 4 instruments carried, the XML parsing framework used in archive list validation will be reused for the label after some necessary adjustments; 2) all the image data acquired by the panorama camera, landing camera and lunar mineralogical spectrometer should use an Array_2D_Image/Array_3D_Image object to store image data, and use a Table_Character object to store image frame header; the tabulated data acquired by the lunar regolith penetrating radar should use a Table_Binary object to store measurements.
Analysis towards VMEM File of a Suspended Virtual Machine
NASA Astrophysics Data System (ADS)
Song, Zheng; Jin, Bo; Sun, Yongqing
With the popularity of virtual machines, forensic investigators are challenged with more complicated situations, among which discovering the evidences in virtualized environment is of significant importance. This paper mainly analyzes the file suffixed with .vmem in VMware Workstation, which stores all pseudo-physical memory into an image. The internal file structure of .vmem file is studied and disclosed. Key information about processes and threads of a suspended virtual machine is revealed. Further investigation into the Windows XP SP3 heap contents is conducted and a proof-of-concept tool is provided. Different methods to obtain forensic memory images are introduced, with both advantages and limits analyzed. We conclude with an outlook.
User's manual for SEDCALC, a computer program for computation of suspended-sediment discharge
Koltun, G.F.; Gray, John R.; McElhone, T.J.
1994-01-01
Sediment-Record Calculations (SEDCALC), a menu-driven set of interactive computer programs, was developed to facilitate computation of suspended-sediment records. The programs comprising SEDCALC were developed independently in several District offices of the U.S. Geological Survey (USGS) to minimize the intensive labor associated with various aspects of sediment-record computations. SEDCALC operates on suspended-sediment-concentration data stored in American Standard Code for Information Interchange (ASCII) files in a predefined card-image format. Program options within SEDCALC can be used to assist in creating and editing the card-image files, as well as to reformat card-image files to and from formats used by the USGS Water-Quality System. SEDCALC provides options for creating card-image files containing time series of equal-interval suspended-sediment concentrations from 1. digitized suspended-sediment-concentration traces, 2. linear interpolation between log-transformed instantaneous suspended-sediment-concentration data stored at unequal time intervals, and 3. nonlinear interpolation between log-transformed instantaneous suspended-sediment-concentration data stored at unequal time intervals. Suspended-sediment discharge can be computed from the streamflow and suspended-sediment-concentration data or by application of transport relations derived by regressing log-transformed instantaneous streamflows on log-transformed instantaneous suspended-sediment concentrations or discharges. The computed suspended-sediment discharge data are stored in card-image files that can be either directly imported to the USGS Automated Data Processing System or used to generate plots by means of other SEDCALC options.
,
2006-01-01
This chapter describes data used in support of the process being applied by the U.S. Geological Survey (USGS) National Oil and Gas Assessment (NOGA) project. Digital tabular data used in this report and archival data that permit the user to perform further analyses are available elsewhere on the CD-ROM. Computers and software may import the data without transcription from the Portable Document Format files (.pdf files) of the text by the reader. Because of the number and variety of platforms and software available, graphical images are provided as .pdf files and tabular data are provided in a raw form as tab-delimited text files (.tab files).
Klett, T.R.; Le, P.A.
2006-01-01
This chapter describes data used in support of the process being applied by the U.S. Geological Survey (USGS) National Oil and Gas Assessment (NOGA) project. Digital tabular data used in this report and archival data that permit the user to perform further analyses are available elsewhere on the CD-ROM. Computers and software may import the data without transcription from the Portable Document Format files (.pdf files) of the text by the reader. Because of the number and variety of platforms and software available, graphical images are provided as .pdf files and tabular data are provided in a raw form as tab-delimited text files (.tab files).
Evaluation of Pre-Service Teachers' Images of Science Teaching in Turkey
ERIC Educational Resources Information Center
Yilmaz, Hulya; Turkmen, Hakan; Pedersen, Jon E.; Huyuguzel Cavas, Pinar
2007-01-01
The purpose of this study is to investigate elementary pre-service teachers' image of science teaching, analyze the gender differences in image of science teaching, and evaluate restructured 2004 education reform by using a Draw-A-Science-Teacher-Test Checklist (DASTT-C). Two hundred thirteen (213) pre-service elementary teachers from three…
NASA Technical Reports Server (NTRS)
Kwok, John H.; Call, Jared A.; Khanampornpan, Teerapat
2012-01-01
This software automatically processes Sally Ride Science (SRS) delivered MoonKAM camera control files (ccf) into uplink products for the GRAIL-A and GRAIL-B spacecraft as part of an education and public outreach (EPO) extension to the Grail Mission. Once properly validated and deemed safe for execution onboard the spacecraft, MoonKommand generates the command products via the Automated Sequence Processor (ASP) and generates uplink (.scmf) files for radiation to the Grail-A and/or Grail-B spacecraft. Any errors detected along the way are reported back to SRS via email. With Moon Kommand, SRS can control their EPO instrument as part of a fully automated process. Inputs are received from SRS as either image capture files (.ccficd) for new image requests, or downlink/delete files (.ccfdl) for requesting image downlink from the instrument and on-board memory management. The Moon - Kommand outputs are command and file-load (.scmf) files that will be uplinked by the Deep Space Network (DSN). Without MoonKommand software, uplink product generation for the MoonKAM instrument would be a manual process. The software is specific to the Moon - KAM instrument on the GRAIL mission. At the time of this writing, the GRAIL mission was making final preparations to begin the science phase, which was scheduled to continue until June 2012.
Jordan, Teresa E.
2015-09-30
This submission of Utilization Analysis data to the Geothermal Data Repository (GDR) node of the National Geothermal Data System (NGDS) is in support of Phase 1 Low Temperature Geothermal Play Fairway Analysis for the Appalachian Basin (project DE-EE0006726). The submission includes data pertinent to the methods and results of an analysis of the Surface Levelized Cost of Heat (SLCOH) for US Census Bureau Places within the study area. This was calculated using a modification of a program called GEOPHIRES, available at http://koenraadbeckers.net/geophires/index.php. The MATLAB modules used in conjunction with GEOPHIRES, the MATLAB data input file, the GEOPHIRES output data file, and an explanation of the software components have been provided. Results of the SLCOH analysis appear on 4 .png image files as mapped risk of heat utilization. For each of the 4 image (.png) files, there is an accompanying georeferenced TIF (.tif) file by the same name. In addition to calculating SLCOH, this Task 4 also identified many sites that may be prospects for use of a geothermal district heating system, based on their size and industry, rather than on the SLCOH. An industry sorted listing of the sites (.xlsx) and a map of these sites plotted as a layer onto different iterations of maps combining the three geological risk factors (Thermal Quality, Natural Reservoir Quality, and Risk of Seismicity) has been provided. In addition to the 6 image (.png) files of the maps in this series, a shape (.shp) file and 7 associated files are included as well. Finally, supporting files (.pdf) describing the utilization analysis methodology and summarizing the anticipated permitting for a deep district heating system are supplied. UPDATE: Newer version of the Utilization Analysis has been added here: https://gdr.openei.org/submissions/878
GPFA-AB_Phase1UtilizationTask4DataUpload
Teresa E. Jordan
2015-09-30
This submission of Utilization Analysis data to the Geothermal Data Repository (GDR) node of the National Geothermal Data System (NGDS) is in support of Phase 1 Low Temperature Geothermal Play Fairway Analysis for the Appalachian Basin (project DE-EE0006726). The submission includes data pertinent to the methods and results of an analysis of the Surface Levelized Cost of Heat (SLCOH) for US Census Bureau ‘Places’ within the study area. This was calculated using a modification of a program called GEOPHIRES, available at http://koenraadbeckers.net/geophires/index.php. The MATLAB modules used in conjunction with GEOPHIRES, the MATLAB data input file, the GEOPHIRES output data file, and an explanation of the software components have been provided. Results of the SLCOH analysis appear on 4 .png image files as mapped ‘risk’ of heat utilization. For each of the 4 image (.png) files, there is an accompanying georeferenced TIF (.tif) file by the same name. In addition to calculating SLCOH, this Task 4 also identified many sites that may be prospects for use of a geothermal district heating system, based on their size and industry, rather than on the SLCOH. An industry sorted listing of the sites (.xlsx) and a map of these sites plotted as a layer onto different iterations of maps combining the three geological risk factors (Thermal Quality, Natural Reservoir Quality, and Risk of Seismicity) has been provided. In addition to the 6 image (.png) files of the maps in this series, a shape (.shp) file and 7 associated files are included as well. Finally, supporting files (.pdf) describing the utilization analysis methodology and summarizing the anticipated permitting for a deep district heating system are supplied.
Short-Term File Reference Patterns in a UNIX Environment,
1986-03-01
accounts mentioned ahose. This includes major administrative and status files (for example, /etc/ passwd ), system libraries, system include files and so on...34 files are those appearing in / and /etc. Examples are /vmunix (the bootable kernel image) and /etc/ passwd (passwords and other information on accounts...as /etc/ passwd ). The small size of opened files (55% are under 1024 bytes, a common block transfer size, and 75% are under 4096 bytes) suggests that
Reprocessing of multi-channel seismic-reflection data collected in the Beaufort Sea
Agena, W.F.; Lee, Myung W.; Hart, P.E.
2000-01-01
Contained on this set of two CD-ROMs are stacked and migrated multi-channel seismic-reflection data for 65 lines recorded in the Beaufort Sea by the United States Geological Survey in 1977. All data were reprocessed by the USGS using updated processing methods resulting in improved interpretability. Each of the two CD-ROMs contains the following files: 1) 65 files containing the digital seismic data in standard, SEG-Y format; 2) 1 file containing navigation data for the 65 lines in standard SEG-P1 format; 3) an ASCII text file with cross-reference information for relating the sequential trace numbers on each line to cdp numbers and shotpoint numbers; 4) 2 small scale graphic images (stacked and migrated) of a segment of line 722 in Adobe Acrobat (R) PDF format; 5) a graphic image of the location map, generated from the navigation file; 6) PlotSeis, an MS-DOS Application that allows PC users to interactively view the SEG-Y files; 7) a PlotSeis documentation file; and 8) an explanation of the processing used to create the final seismic sections (this document).
Processing digital images and calculation of beam emittance (pepper-pot method for the Krion source)
NASA Astrophysics Data System (ADS)
Alexandrov, V. S.; Donets, E. E.; Nyukhalova, E. V.; Kaminsky, A. K.; Sedykh, S. N.; Tuzikov, A. V.; Philippov, A. V.
2016-12-01
Programs for the pre-processing of photographs of beam images on the mask based on Wolfram Mathematica and Origin software are described. Angles of rotation around the axis and in the vertical plane are taken into account in the generation of the file with image coordinates. Results of the emittance calculation by the Pep_emit program written in Visual Basic using the generated file in the test mode are presented.
2009-03-01
Department of Defense, Washington Headquarters Services , Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite... discovery (teaching by problem solving), and exploratory (teaching by exploration). Research suggests while guided discovery and exploratory training...34 College Student Journal 38 (2004): 482-493. MasterFILE Premier. EBSCO . 4 June 2008. - This study was conducted to determine whether an introductory
Mahesh, MC; Bhandary, Shreetha
2017-01-01
Introduction Stresses generated during root canal instrumentation have been reported to cause apical cracks. The smaller, less pronounced defects like cracks can later propagate into vertical root fracture, when the tooth is subjected to repeated stresses from endodontic or restorative procedures. Aim This study evaluated occurrence of apical cracks with stainless steel hand files, rotary NiTi RaCe and K3 files at two different instrumentation lengths. Materials and Methods In the present in vitro study, 60 mandibular premolars were mounted in resin blocks with simulated periodontal ligament. Apical 3 mm of the root surfaces were exposed and stained using India ink. Preoperative images of root apices were obtained at 100x using stereomicroscope. The teeth were divided into six groups of 10 each. First two groups were instrumented with stainless steel files, next two groups with rotary NiTi RaCe files and the last two groups with rotary NiTi K3 files. The instrumentation was carried out till the apical foramen (Working Length-WL) and 1 mm short of the apical foramen (WL-1) with each file system. After root canal instrumentation, postoperative images of root apices were obtained. Preoperative and postoperative images were compared and the occurrence of cracks was recorded. Descriptive statistical analysis and Chi-square tests were used to analyze the results. Results Apical root cracks were seen in 30%, 35% and 20% of teeth instrumented with K-files, RaCe files and K3 files respectively. There was no statistical significance among three instrumentation systems in the formation of apical cracks (p=0.563). Apical cracks were seen in 40% and 20% of teeth instrumented with K-files; 60% and 10% of teeth with RaCe files and 40% and 0% of teeth with K3 files at WL and WL-1 respectively. For groups instrumented with hand files there was no statistical significance in number of cracks at WL and WL-1 (p=0.628). But for teeth instrumented with RaCe files and K3 files significantly more number of cracks were seen at WL than WL-1 (p=0.057 for RaCe files and p=0.087 for K3 files). Conclusion There was no statistical significance between stainless steel hand files and rotary files in terms of crack formation. Instrumentation length had a significant effect on the formation of cracks when rotary files were used. Using rotary instruments 1 mm short of apical foramen caused lesser crack formation. But, there was no statistically significant difference in number of cracks formed with hand files at two instrumentation levels. PMID:28274036
Devale, Madhuri R; Mahesh, M C; Bhandary, Shreetha
2017-01-01
Stresses generated during root canal instrumentation have been reported to cause apical cracks. The smaller, less pronounced defects like cracks can later propagate into vertical root fracture, when the tooth is subjected to repeated stresses from endodontic or restorative procedures. This study evaluated occurrence of apical cracks with stainless steel hand files, rotary NiTi RaCe and K3 files at two different instrumentation lengths. In the present in vitro study, 60 mandibular premolars were mounted in resin blocks with simulated periodontal ligament. Apical 3 mm of the root surfaces were exposed and stained using India ink. Preoperative images of root apices were obtained at 100x using stereomicroscope. The teeth were divided into six groups of 10 each. First two groups were instrumented with stainless steel files, next two groups with rotary NiTi RaCe files and the last two groups with rotary NiTi K3 files. The instrumentation was carried out till the apical foramen (Working Length-WL) and 1 mm short of the apical foramen (WL-1) with each file system. After root canal instrumentation, postoperative images of root apices were obtained. Preoperative and postoperative images were compared and the occurrence of cracks was recorded. Descriptive statistical analysis and Chi-square tests were used to analyze the results. Apical root cracks were seen in 30%, 35% and 20% of teeth instrumented with K-files, RaCe files and K3 files respectively. There was no statistical significance among three instrumentation systems in the formation of apical cracks (p=0.563). Apical cracks were seen in 40% and 20% of teeth instrumented with K-files; 60% and 10% of teeth with RaCe files and 40% and 0% of teeth with K3 files at WL and WL-1 respectively. For groups instrumented with hand files there was no statistical significance in number of cracks at WL and WL-1 (p=0.628). But for teeth instrumented with RaCe files and K3 files significantly more number of cracks were seen at WL than WL-1 (p=0.057 for RaCe files and p=0.087 for K3 files). There was no statistical significance between stainless steel hand files and rotary files in terms of crack formation. Instrumentation length had a significant effect on the formation of cracks when rotary files were used. Using rotary instruments 1 mm short of apical foramen caused lesser crack formation. But, there was no statistically significant difference in number of cracks formed with hand files at two instrumentation levels.
Is the bang worth the buck? A RAID performance study
NASA Technical Reports Server (NTRS)
Hauser, Susan E.; Berman, Lewis E.; Thoma, George R.
1996-01-01
Expecting a high data delivery rate as well as data protection, the Lister Hill National Center for Biomedical Communications procured a RAID system to house image files for image delivery applications. A study was undertaken to determine the configuration of the RAID system that would provide for the fastest retrieval of image files. Average retrieval times with single and with concurrent users were measured for several stripe widths and several numbers of disks for RAID levels 0, 0+1 and 5. These are compared to each other and to average retrieval times for non-RAID configurations of the same hardware. Although the study in ongoing, a few conclusions have emerged regarding the tradeoffs among the different configurations with respect to file retrieval speed and cost.
Distributed PACS using distributed file system with hierarchical meta data servers.
Hiroyasu, Tomoyuki; Minamitani, Yoshiyuki; Miki, Mitsunori; Yokouchi, Hisatake; Yoshimi, Masato
2012-01-01
In this research, we propose a new distributed PACS (Picture Archiving and Communication Systems) which is available to integrate several PACSs that exist in each medical institution. The conventional PACS controls DICOM file into one data-base. On the other hand, in the proposed system, DICOM file is separated into meta data and image data and those are stored individually. Using this mechanism, since file is not always accessed the entire data, some operations such as finding files, changing titles, and so on can be performed in high-speed. At the same time, as distributed file system is utilized, accessing image files can also achieve high-speed access and high fault tolerant. The introduced system has a more significant point. That is the simplicity to integrate several PACSs. In the proposed system, only the meta data servers are integrated and integrated system can be constructed. This system also has the scalability of file access with along to the number of file numbers and file sizes. On the other hand, because meta-data server is integrated, the meta data server is the weakness of this system. To solve this defect, hieratical meta data servers are introduced. Because of this mechanism, not only fault--tolerant ability is increased but scalability of file access is also increased. To discuss the proposed system, the prototype system using Gfarm was implemented. For evaluating the implemented system, file search operating time of Gfarm and NFS were compared.
VizieR Online Data Catalog: C/2012 F6 (Lemmon) and C/2012 S1 (ISON) maps (Cordiner+, 2014)
NASA Astrophysics Data System (ADS)
Cordiner, M. A.; Remijan, A. J.; Boissier, J.; Milam, S. N.; Mumma, M. J.; Charnley, S. B.; Paganini, L.; Villanueva, G.; Bockelee-Morvan, D.; Kuan, Y.-J.; Chuang, Y.-L.; Lis, D. C.; Biver, N.; Crovisier, J.; Minniti, D.; Coulson, I. M.
2017-04-01
WCS-calibrated fits image files of the molecular flux maps shown in Figure 1 for HCN, HNC and H2CO observed in comets C/2012 F6 (Lemmon) and C/2012 S1 (ISON) using ALMA. The files are labeled with the corresponding comet and molecule names. The files are standard two-dimensional fits images, which can be opened in fits image viewers such as SAOimage DS9, CASA viewer, or Starlink Gaia. GIMP and Adobe Photoshop can also be used, provided the appropriate plugins are present. The images contain flux values (in units of Jansky km/s per beam), as a function of celestial coordinate in the J2000 equatorial system. Due to the cometary motions, the absolute coordinate systems are accurate only at the start of the observations (dates and times are given in Table 1). These images are the result of integrating the (3D) ALMA data cubes over the full widths of the observed spectral lines (equivalent to collapsing the data cubes along their respective spectral/velocity axes). The beam dimensions (BMAJ and BMIN), corresponding to the angular resolution of the images, are given in the image headers in units of degrees. object.dat : -------------------------------------------------------------------------------- Code Name Elem q e i H1 d AU deg mag -------------------------------------------------------------------------------- C/2012 F6 Lemmon 2456375.5 0.7312461 0.9985125 82.607966 7.96 C/2012 S1 Ison 2456624.5 0.0124515 0.9998921 64.401571 6.11 (2 data files).
NASA Astrophysics Data System (ADS)
Shiinoki, Takehiro; Hanazawa, Hideki; Yuasa, Yuki; Fujimoto, Koya; Uehara, Takuya; Shibuya, Keiko
2017-02-01
A combined system comprising the TrueBeam linear accelerator and a new real-time tumour-tracking radiotherapy system, SyncTraX, was installed at our institution. The objectives of this study are to develop a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine electronic portal image device (EPID) images and a log file and to verify this treatment in clinical cases. Respiratory-gated radiotherapy was performed using TrueBeam and the SyncTraX system. Cine EPID images and a log file were acquired for a phantom and three patients during the course of the treatment. Digitally reconstructed radiographs (DRRs) were created for each treatment beam using a planning CT set. The cine EPID images, log file, and DRRs were analysed using a developed software. For the phantom case, the accuracy of the proposed method was evaluated to verify the respiratory-gated radiotherapy. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker used as an internal surrogate were calculated to evaluate the gating accuracy and set-up uncertainty in the superior-inferior (SI), anterior-posterior (AP), and left-right (LR) directions. The proposed method achieved high accuracy for the phantom verification. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker were ⩽3 mm and ±3 mm in the SI, AP, and LR directions. We proposed a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine EPID images and a log file and showed that this treatment is performed with high accuracy in clinical cases. This work was partly presented at the 58th Annual meeting of American Association of Physicists in Medicine.
Shiinoki, Takehiro; Hanazawa, Hideki; Yuasa, Yuki; Fujimoto, Koya; Uehara, Takuya; Shibuya, Keiko
2017-02-21
A combined system comprising the TrueBeam linear accelerator and a new real-time tumour-tracking radiotherapy system, SyncTraX, was installed at our institution. The objectives of this study are to develop a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine electronic portal image device (EPID) images and a log file and to verify this treatment in clinical cases. Respiratory-gated radiotherapy was performed using TrueBeam and the SyncTraX system. Cine EPID images and a log file were acquired for a phantom and three patients during the course of the treatment. Digitally reconstructed radiographs (DRRs) were created for each treatment beam using a planning CT set. The cine EPID images, log file, and DRRs were analysed using a developed software. For the phantom case, the accuracy of the proposed method was evaluated to verify the respiratory-gated radiotherapy. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker used as an internal surrogate were calculated to evaluate the gating accuracy and set-up uncertainty in the superior-inferior (SI), anterior-posterior (AP), and left-right (LR) directions. The proposed method achieved high accuracy for the phantom verification. For the clinical cases, the intra- and inter-fractional variations of the fiducial marker were ⩽3 mm and ±3 mm in the SI, AP, and LR directions. We proposed a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine EPID images and a log file and showed that this treatment is performed with high accuracy in clinical cases.
SU-F-T-469: A Clinically Observed Discrepancy Between Image-Based and Log- Based MLC Position
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neal, B; Ahmed, M; Siebers, J
2016-06-15
Purpose: To present a clinical case which challenges the base assumption of log-file based QA, by showing that the actual position of a MLC leaf can suddenly deviate from its programmed and logged position by >1 mm as observed with real-time imaging. Methods: An EPID-based exit-fluence dosimetry system designed to prevent gross delivery errors was used in cine mode to capture portal images during treatment. Visual monitoring identified an anomalous MLC leaf pair gap not otherwise detected by the automatic position verification. The position of the erred leaf was measured on EPID images and log files were analyzed for themore » treatment in question, the prior day’s treatment, and for daily MLC test patterns acquired on those treatment days. Additional standard test patterns were used to quantify the leaf position. Results: Whereas the log file reported no difference between planned and recorded positions, image-based measurements showed the leaf to be 1.3±0.1 mm medial from the planned position. This offset was confirmed with the test pattern irradiations. Conclusion: It has been clinically observed that log-file derived leaf positions can differ from their actual positions by >1 mm, and therefore cannot be considered to be the actual leaf positions. This cautions the use of log-based methods for MLC or patient quality assurance without independent confirmation of log integrity. Frequent verification of MLC positions through independent means is a necessary precondition to trusting log file records. Intra-treatment EPID imaging provides a method to capture departures from MLC planned positions. Work was supported in part by Varian Medical Systems.« less
Robichaud, Guillaume; Garrard, Kenneth P; Barry, Jeremy A; Muddiman, David C
2013-05-01
During the past decade, the field of mass spectrometry imaging (MSI) has greatly evolved, to a point where it has now been fully integrated by most vendors as an optional or dedicated platform that can be purchased with their instruments. However, the technology is not mature and multiple research groups in both academia and industry are still very actively studying the fundamentals of imaging techniques, adapting the technology to new ionization sources, and developing new applications. As a result, there important varieties of data file formats used to store mass spectrometry imaging data and, concurrent to the development of MSi, collaborative efforts have been undertaken to introduce common imaging data file formats. However, few free software packages to read and analyze files of these different formats are readily available. We introduce here MSiReader, a free open source application to read and analyze high resolution MSI data from the most common MSi data formats. The application is built on the Matlab platform (Mathworks, Natick, MA, USA) and includes a large selection of data analysis tools and features. People who are unfamiliar with the Matlab language will have little difficult navigating the user-friendly interface, and users with Matlab programming experience can adapt and customize MSiReader for their own needs.
NASA Astrophysics Data System (ADS)
Robichaud, Guillaume; Garrard, Kenneth P.; Barry, Jeremy A.; Muddiman, David C.
2013-05-01
During the past decade, the field of mass spectrometry imaging (MSI) has greatly evolved, to a point where it has now been fully integrated by most vendors as an optional or dedicated platform that can be purchased with their instruments. However, the technology is not mature and multiple research groups in both academia and industry are still very actively studying the fundamentals of imaging techniques, adapting the technology to new ionization sources, and developing new applications. As a result, there important varieties of data file formats used to store mass spectrometry imaging data and, concurrent to the development of MSi, collaborative efforts have been undertaken to introduce common imaging data file formats. However, few free software packages to read and analyze files of these different formats are readily available. We introduce here MSiReader, a free open source application to read and analyze high resolution MSI data from the most common MSi data formats. The application is built on the Matlab platform (Mathworks, Natick, MA, USA) and includes a large selection of data analysis tools and features. People who are unfamiliar with the Matlab language will have little difficult navigating the user-friendly interface, and users with Matlab programming experience can adapt and customize MSiReader for their own needs.
Detection and segmentation of multiple touching product inspection items
NASA Astrophysics Data System (ADS)
Casasent, David P.; Talukder, Ashit; Cox, Westley; Chang, Hsuan-Ting; Weber, David
1996-12-01
X-ray images of pistachio nuts on conveyor trays for product inspection are considered. The first step in such a processor is to locate each individual item and place it in a separate file for input to a classifier to determine the quality of each nut. This paper considers new techniques to: detect each item (each nut can be in any orientation, we employ new rotation-invariant filters to locate each item independent of its orientation), produce separate image files for each item [a new blob coloring algorithm provides this for isolated (non-touching) input items], segmentation to provide separate image files for touching or overlapping input items (we use a morphological watershed transform to achieve this), and morphological processing to remove the shell and produce an image of only the nutmeat. Each of these operations and algorithms are detailed and quantitative data for each are presented for the x-ray image nut inspection problem noted. These techniques are of general use in many different product inspection problems in agriculture and other areas.
Alton Ochsner's Card File: A Profile of Medical History
Trotter, Michael C.
2010-01-01
Alton Ochsner was a giant of American surgery. His career encompassed patient care, teaching, and research as symbolized on the original seal of the Ochsner Clinic. His ideas were innovative and groundbreaking on many fronts, making him and the Ochsner Clinic nationally and internationally known. Examination of his card file, a simple metal box with 3 × 5 index cards and subject dividers, gives extraordinary insight into the professional interests of this remarkable physician and surgeon. PMID:21603382
Legato: Personal Computer Software for Analyzing Pressure-Sensitive Paint Data
NASA Technical Reports Server (NTRS)
Schairer, Edward T.
2001-01-01
'Legato' is personal computer software for analyzing radiometric pressure-sensitive paint (PSP) data. The software is written in the C programming language and executes under Windows 95/98/NT operating systems. It includes all operations normally required to convert pressure-paint image intensities to normalized pressure distributions mapped to physical coordinates of the test article. The program can analyze data from both single- and bi-luminophore paints and provides for both in situ and a priori paint calibration. In addition, there are functions for determining paint calibration coefficients from calibration-chamber data. The software is designed as a self-contained, interactive research tool that requires as input only the bare minimum of information needed to accomplish each function, e.g., images, model geometry, and paint calibration coefficients (for a priori calibration) or pressure-tap data (for in situ calibration). The program includes functions that can be used to generate needed model geometry files for simple model geometries (e.g., airfoils, trapezoidal wings, rotor blades) based on the model planform and airfoil section. All data files except images are in ASCII format and thus are easily created, read, and edited. The program does not use database files. This simplifies setup but makes the program inappropriate for analyzing massive amounts of data from production wind tunnels. Program output consists of Cartesian plots, false-colored real and virtual images, pressure distributions mapped to the surface of the model, assorted ASCII data files, and a text file of tabulated results. Graphical output is displayed on the computer screen and can be saved as publication-quality (PostScript) files.
NASA Technical Reports Server (NTRS)
Norikane, L.; Freeman, A.; Way, J.; Okonek, S.; Casey, R.
1992-01-01
Recent updates to a geographical information system (GIS) called VICAR (Video Image Communication and Retrieval)/IBIS are described. The system is designed to handle data from many different formats (vector, raster, tabular) and many different sources (models, radar images, ground truth surveys, optical images). All the data are referenced to a single georeference plane, and average or typical values for parameters defined within a polygonal region are stored in a tabular file, called an info file. The info file format allows tracking of data in time, maintenance of links between component data sets and the georeference image, conversion of pixel values to `actual' values (e.g., radar cross-section, luminance, temperature), graph plotting, data manipulation, generation of training vectors for classification algorithms, and comparison between actual measurements and model predictions (with ground truth data as input).
VizieR Online Data Catalog: Jekyll & Hyde galaxies ALMA cube & spectrum (Schreiber+, 2018)
NASA Astrophysics Data System (ADS)
Schreiber, C.; Labbe, I.; Glazebrook, K.; Bekiaris, G.; Papovich, C.; Costa, T.; Elbaz, D.; Kacprzak, G. G.; Nanayakkara, T.; Oesch, P.; Pannella, M.; Spitler, L.; Straatman, C.; Tran, K.-V.; Wang, T.
2017-11-01
These files consist of the full ALMA data cube for the galaxies Jekyll and Hyde, together with the extracted continuum image and the spectrum of Hyde. The data cube was produced by CASA (v4.7.0), the continuum image was constructed as the weighted average in line-free channels, and the spectrum was extracted at the peak flux position of Hyde. The data cube and spectrum files contain two extensions, one for the flux, and another for the uncertainty. This uncertainty was determined from the RMS of the cube data between 2 and 8" away from the center. All fluxes are in units of Jansky, and the spectral axis is given in observed frequency (GHz). The images were not CLEANed, therefore the dirty beam (which is also provided here) is the correct point-spread function to use when analyzing these images. (2 data files).
Klett, T.R.; Le, P.A.
2007-01-01
This chapter describes data used in support of the assessment process. Digital tabular data used in this report and archival data that permit the user to perform further analyses are available elsewhere on this CD–ROM. Computers and software may import the data without transcription from the portable document format (.pdf) files of the text by the reader. Because of the number and variety of platforms and software available, graphical images are provided as .pdf files and tabular data are provided in a raw form as tab-delimited text files (.tab files).
WE-G-213CD-03: A Dual Complementary Verification Method for Dynamic Tumor Tracking on Vero SBRT.
Poels, K; Depuydt, T; Verellen, D; De Ridder, M
2012-06-01
to use complementary cine EPID and gimbals log file analysis for in-vivo tracking accuracy monitoring. A clinical prototype of dynamic tracking (DT) was installed on the Vero SBRT system. This prototype version allowed tumor tracking by gimballed linac rotations using an internal-external correspondence model. The DT prototype software allowed the detailed logging of all applied gimbals rotations during tracking. The integration of an EPID on the vero system allowed the acquisition of cine EPID images during DT. We quantified the tracking error on cine EPID (E-EPID) by subtracting the target center (fiducial marker detection) and the field centroid. Dynamic gimbals log file information was combined with orthogonal x-ray verification images to calculate the in-vivo tracking error (E-kVLog). The correlation between E-kVLog and E-EPID was calculated for validation of the gimbals log file. Further, we investigated the sensitivity of the log file tracking error by introducing predefined systematic tracking errors. As an application we calculate gimbals log file tracking error for dynamic hidden target tests to investigate gravity effects and decoupled gimbals rotation from gantry rotation. Finally, calculating complementary cine EPID and log file tracking errors evaluated the clinical accuracy of dynamic tracking. A strong correlation was found between log file and cine EPID tracking error distribution during concurrent measurements (R=0.98). We found sensitivity in the gimbals log files to detect a systematic tracking error up to 0.5 mm. Dynamic hidden target tests showed no gravity influence on tracking performance and high degree of decoupled gimbals and gantry rotation during dynamic arc dynamic tracking. A submillimetric agreement between clinical complementary tracking error measurements was found. Redundancy of the internal gimbals log file with x-ray verification images with complementary independent cine EPID images was implemented to monitor the accuracy of gimballed tumor tracking on Vero SBRT. Research was financially supported by the Flemish government (FWO), Hercules Foundation and BrainLAB AG. © 2012 American Association of Physicists in Medicine.
TOPPE: A framework for rapid prototyping of MR pulse sequences.
Nielsen, Jon-Fredrik; Noll, Douglas C
2018-06-01
To introduce a framework for rapid prototyping of MR pulse sequences. We propose a simple file format, called "TOPPE", for specifying all details of an MR imaging experiment, such as gradient and radiofrequency waveforms and the complete scan loop. In addition, we provide a TOPPE file "interpreter" for GE scanners, which is a binary executable that loads TOPPE files and executes the sequence on the scanner. We also provide MATLAB scripts for reading and writing TOPPE files and previewing the sequence prior to hardware execution. With this setup, the task of the pulse sequence programmer is reduced to creating TOPPE files, eliminating the need for hardware-specific programming. No sequence-specific compilation is necessary; the interpreter only needs to be compiled once (for every scanner software upgrade). We demonstrate TOPPE in three different applications: k-space mapping, non-Cartesian PRESTO whole-brain dynamic imaging, and myelin mapping in the brain using inhomogeneous magnetization transfer. We successfully implemented and executed the three example sequences. By simply changing the various TOPPE sequence files, a single binary executable (interpreter) was used to execute several different sequences. The TOPPE file format is a complete specification of an MR imaging experiment, based on arbitrary sequences of a (typically small) number of unique modules. Along with the GE interpreter, TOPPE comprises a modular and flexible platform for rapid prototyping of new pulse sequences. Magn Reson Med 79:3128-3134, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Shaping ability of 4 different single-file systems in simulated S-shaped canals.
Saleh, Abdulrahman Mohammed; Vakili Gilani, Pouyan; Tavanafar, Saeid; Schäfer, Edgar
2015-04-01
The aim of this study was to compare the shaping ability of 4 different single-file systems in simulated S-shaped canals. Sixty-four S-shaped canals in resin blocks were prepared to an apical size of 25 using Reciproc (VDW, Munich, Germany), WaveOne (Dentsply Maillefer, Ballaigues, Switzerland), OneShape (Micro Méga, Besançon, France), and F360 (Komet Brasseler, Lemgo, Germany) (n = 16 canals/group) systems. Composite images were made from the superimposition of pre- and postinstrumentation images. The amount of resin removed by each system was measured by using a digital template and image analysis software. Canal aberrations and the preparation time were also recorded. The data were statistically analyzed by using analysis of variance, Tukey, and chi-square tests. Canals prepared with the F360 and OneShape systems were better centered compared with the Reciproc and WaveOne systems. Reciproc and WaveOne files removed significantly greater amounts of resin from the inner side of both curvatures (P < .05). Instrumentation with OneShape and Reciproc files was significantly faster compared with WaveOne and F360 files (P < .05). No instrument fractured during canal preparation. Under the conditions of this study, all single-file instruments were safe to use and were able to prepare the canals efficiently. However, single-file systems that are less tapered seem to be more favorable when preparing S-shaped canals. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Campbell-Washburn, Adrienne E; Xue, Hui; Lederman, Robert J; Faranesh, Anthony Z; Hansen, Michael S
2016-06-01
MRI-guided interventions demand high frame rate imaging, making fast imaging techniques such as spiral imaging and echo planar imaging (EPI) appealing. In this study, we implemented a real-time distortion correction framework to enable the use of these fast acquisitions for interventional MRI. Distortions caused by gradient waveform inaccuracies were corrected using the gradient impulse response function (GIRF), which was measured by standard equipment and saved as a calibration file on the host computer. This file was used at runtime to calculate the predicted k-space trajectories for image reconstruction. Additionally, the off-resonance reconstruction frequency was modified in real time to interactively deblur spiral images. Real-time distortion correction for arbitrary image orientations was achieved in phantoms and healthy human volunteers. The GIRF-predicted k-space trajectories matched measured k-space trajectories closely for spiral imaging. Spiral and EPI image distortion was visibly improved using the GIRF-predicted trajectories. The GIRF calibration file showed no systematic drift in 4 months and was demonstrated to correct distortions after 30 min of continuous scanning despite gradient heating. Interactive off-resonance reconstruction was used to sharpen anatomical boundaries during continuous imaging. This real-time distortion correction framework will enable the use of these high frame rate imaging methods for MRI-guided interventions. Magn Reson Med 75:2278-2285, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Campbell-Washburn, Adrienne E; Xue, Hui; Lederman, Robert J; Faranesh, Anthony Z; Hansen, Michael S
2015-01-01
Purpose MRI-guided interventions demand high frame-rate imaging, making fast imaging techniques such as spiral imaging and echo planar imaging (EPI) appealing. In this study, we implemented a real-time distortion correction framework to enable the use of these fast acquisitions for interventional MRI. Methods Distortions caused by gradient waveform inaccuracies were corrected using the gradient impulse response function (GIRF), which was measured by standard equipment and saved as a calibration file on the host computer. This file was used at runtime to calculate the predicted k-space trajectories for image reconstruction. Additionally, the off-resonance reconstruction frequency was modified in real-time to interactively de-blur spiral images. Results Real-time distortion correction for arbitrary image orientations was achieved in phantoms and healthy human volunteers. The GIRF predicted k-space trajectories matched measured k-space trajectories closely for spiral imaging. Spiral and EPI image distortion was visibly improved using the GIRF predicted trajectories. The GIRF calibration file showed no systematic drift in 4 months and was demonstrated to correct distortions after 30 minutes of continuous scanning despite gradient heating. Interactive off-resonance reconstruction was used to sharpen anatomical boundaries during continuous imaging. Conclusions This real-time distortion correction framework will enable the use of these high frame-rate imaging methods for MRI-guided interventions. PMID:26114951
Some utilities to help produce Rich Text Files from Stata.
Gillman, Matthew S
Producing RTF files from Stata can be difficult and somewhat cryptic. Utilities are introduced to simplify this process; one builds up a table row-by-row, another inserts a PNG image file into an RTF document, and the others start and finish the RTF document.
Klett, T.R.; Le, P.A.
2013-01-01
This chapter describes data used in support of the process being applied by the U.S. Geological Survey (USGS) National Oil and Gas Assessment (NOGA) project. Digital tabular data used in this report and archival data that permit the user to perform further analyses are available elsewhere on this CD–ROM. Computers and software may import the data without transcription from the Portable Document Format files (.pdf files) of the text by the reader. Because of the number and variety of platforms and software available, graphical images are provided as .pdf files and tabular data are provided in a raw form as tab-delimited text files (.tab files).
Caruso, Ronald D
2004-01-01
Proper configuration of software security settings and proper file management are necessary and important elements of safe computer use. Unfortunately, the configuration of software security options is often not user friendly. Safe file management requires the use of several utilities, most of which are already installed on the computer or available as freeware. Among these file operations are setting passwords, defragmentation, deletion, wiping, removal of personal information, and encryption. For example, Digital Imaging and Communications in Medicine medical images need to be anonymized, or "scrubbed," to remove patient identifying information in the header section prior to their use in a public educational or research environment. The choices made with respect to computer security may affect the convenience of the computing process. Ultimately, the degree of inconvenience accepted will depend on the sensitivity of the files and communications to be protected and the tolerance of the user. Copyright RSNA, 2004
Students' ideas about prismatic images: teaching experiments for an image-based approach
NASA Astrophysics Data System (ADS)
Grusche, Sascha
2017-05-01
Prismatic refraction is a classic topic in science education. To investigate how undergraduate students think about prismatic dispersion, and to see how they change their thinking when observing dispersed images, five teaching experiments were done and analysed according to the Model of Educational Reconstruction. For projection through a prism, the students used a 'split image projection' conceptualisation. For the view through a prism, this conceptualisation was not fruitful. Based on the observed images, six of seven students changed to a 'diverted image projection' conceptualisation. From a comparison between students' and scientists' ideas, teaching implications are derived for an image-based approach.
SU-E-T-473: A Patient-Specific QC Paradigm Based On Trajectory Log Files and DICOM Plan Files
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeMarco, J; McCloskey, S; Low, D
Purpose: To evaluate a remote QC tool for monitoring treatment machine parameters and treatment workflow. Methods: The Varian TrueBeamTM linear accelerator is a digital machine that records machine axis parameters and MLC leaf positions as a function of delivered monitor unit or control point. This information is saved to a binary trajectory log file for every treatment or imaging field in the patient treatment session. A MATLAB analysis routine was developed to parse the trajectory log files for a given patient, compare the expected versus actual machine and MLC positions as well as perform a cross-comparison with the DICOM-RT planmore » file exported from the treatment planning system. The parsing routine sorts the trajectory log files based on the time and date stamp and generates a sequential report file listing treatment parameters and provides a match relative to the DICOM-RT plan file. Results: The trajectory log parsing-routine was compared against a standard record and verify listing for patients undergoing initial IMRT dosimetry verification and weekly and final chart QC. The complete treatment course was independently verified for 10 patients of varying treatment site and a total of 1267 treatment fields were evaluated including pre-treatment imaging fields where applicable. In the context of IMRT plan verification, eight prostate SBRT plans with 4-arcs per plan were evaluated based on expected versus actual machine axis parameters. The average value for the maximum RMS MLC error was 0.067±0.001mm and 0.066±0.002mm for leaf bank A and B respectively. Conclusion: A real-time QC analysis program was tested using trajectory log files and DICOM-RT plan files. The parsing routine is efficient and able to evaluate all relevant machine axis parameters during a patient treatment course including MLC leaf positions and table positions at time of image acquisition and during treatment.« less
Using Image Modelling to Teach Newton's Laws with the Ollie Trick
ERIC Educational Resources Information Center
Dias, Marco Adriano; Carvalho, Paulo Simeão; Vianna, Deise Miranda
2016-01-01
Image modelling is a video-based teaching tool that is a combination of strobe images and video analysis. This tool can enable a qualitative and a quantitative approach to the teaching of physics, in a much more engaging and appealling way than the traditional expositive practice. In a specific scenario shown in this paper, the Ollie trick, we…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phillion, D.
This code enables one to display, take line-outs on, and perform various transformations on an image created by an array of integer*2 data. Uncompressed eight-bit TIFF files created on either the Macintosh or the IBM PC may also be read in and converted to a 16 bit signed integer image. This code is designed to handle all the formats used for PDS (photo-densitometer) files at the Lawrence Livermore National Laboratory. These formats are all explained by the application code. The image may be zoomed infinitely and the gray scale mapping can be easily changed. Line-outs may be horizontal or verticalmore » with arbitrary width, angled with arbitrary end points, or taken along any path. This code is usually used to examine spectrograph data. Spectral lines may be identified and a polynomial fit from position to wavelength may be found. The image array can be remapped so that the pixels all have the same change of lambda width. It is not necessary to do this, however. Lineouts may be printed, saved as Cricket tab-delimited files, or saved as PICT2 files. The plots may be linear, semilog, or logarithmic with nice values and proper scientific notation. Typically, spectral lines are curved.« less
Computer vs. Typewriter: Changes in Teaching Methods.
ERIC Educational Resources Information Center
Frankeberger, Lynda
1990-01-01
Factors to consider in making a decision whether to convert traditional typewriting classrooms to microcomputer classrooms include effects on oral instruction, ethical issues in file transfer, and use of keyboarding software and timed writing software. (JOW)
Developing Students' Ideas about Lens Imaging: Teaching Experiments with an Image-Based Approach
ERIC Educational Resources Information Center
Grusche, Sascha
2017-01-01
Lens imaging is a classic topic in physics education. To guide students from their holistic viewpoint to the scientists' analytic viewpoint, an image-based approach to lens imaging has recently been proposed. To study the effect of the image-based approach on undergraduate students' ideas, teaching experiments are performed and evaluated using…
Some utilities to help produce Rich Text Files from Stata
Gillman, Matthew S.
2018-01-01
Producing RTF files from Stata can be difficult and somewhat cryptic. Utilities are introduced to simplify this process; one builds up a table row-by-row, another inserts a PNG image file into an RTF document, and the others start and finish the RTF document. PMID:29731697
Dependency Tree Annotation Software
2015-11-01
formats, and it provides numerous options for customizing how dependency trees are displayed. Built entirely in Java , it can run on a wide range of...tree can be saved as an image, .mxe (a mxGraph editing file), a .conll file, and several other file formats. DTE uses the open source Java version
Fu, Chi-Yung; Petrich, Loren I.
1997-01-01
An image is compressed by identifying edge pixels of the image; creating a filled edge array of pixels each of the pixels in the filled edge array which corresponds to an edge pixel having a value equal to the value of a pixel of the image array selected in response to the edge pixel, and each of the pixels in the filled edge array which does not correspond to an edge pixel having a value which is a weighted average of the values of surrounding pixels in the filled edge array which do correspond to edge pixels; and subtracting the filled edge array from the image array to create a difference array. The edge file and the difference array are then separately compressed and transmitted or stored. The original image is later reconstructed by creating a preliminary array in response to the received edge file, and adding the preliminary array to the received difference array. Filling is accomplished by solving Laplace's equation using a multi-grid technique. Contour and difference file coding techniques also are described. The techniques can be used in a method for processing a plurality of images by selecting a respective compression approach for each image, compressing each of the images according to the compression approach selected, and transmitting each of the images as compressed, in correspondence with an indication of the approach selected for the image.
Fu, C.Y.; Petrich, L.I.
1997-03-25
An image is compressed by identifying edge pixels of the image; creating a filled edge array of pixels each of the pixels in the filled edge array which corresponds to an edge pixel having a value equal to the value of a pixel of the image array selected in response to the edge pixel, and each of the pixels in the filled edge array which does not correspond to an edge pixel having a value which is a weighted average of the values of surrounding pixels in the filled edge array which do correspond to edge pixels; and subtracting the filled edge array from the image array to create a difference array. The edge file and the difference array are then separately compressed and transmitted or stored. The original image is later reconstructed by creating a preliminary array in response to the received edge file, and adding the preliminary array to the received difference array. Filling is accomplished by solving Laplace`s equation using a multi-grid technique. Contour and difference file coding techniques also are described. The techniques can be used in a method for processing a plurality of images by selecting a respective compression approach for each image, compressing each of the images according to the compression approach selected, and transmitting each of the images as compressed, in correspondence with an indication of the approach selected for the image. 16 figs.
Optimal Compression Methods for Floating-point Format Images
NASA Technical Reports Server (NTRS)
Pence, W. D.; White, R. L.; Seaman, R.
2009-01-01
We report on the results of a comparison study of different techniques for compressing FITS images that have floating-point (real*4) pixel values. Standard file compression methods like GZIP are generally ineffective in this case (with compression ratios only in the range 1.2 - 1.6), so instead we use a technique of converting the floating-point values into quantized scaled integers which are compressed using the Rice algorithm. The compressed data stream is stored in FITS format using the tiled-image compression convention. This is technically a lossy compression method, since the pixel values are not exactly reproduced, however all the significant photometric and astrometric information content of the image can be preserved while still achieving file compression ratios in the range of 4 to 8. We also show that introducing dithering, or randomization, when assigning the quantized pixel-values can significantly improve the photometric and astrometric precision in the stellar images in the compressed file without adding additional noise. We quantify our results by comparing the stellar magnitudes and positions as measured in the original uncompressed image to those derived from the same image after applying successively greater amounts of compression.
Kavitha, Swaminathan; Thomas, Eapen; Anadhan, Vasanthakumari; Vijayakumar, Rajendran
2016-01-01
Introduction The intention of root canal preparation is to reduce infected content and create a root canal shape allowing for a well condensed root filling. Therefore, it is not necessary to remove excessive dentine for successful root canal preparation and concern must be taken not to over instrument as perforations can occur in the thin dentinal walls of primary molars. Aim This study was done to evaluate the time preparation, the risk of lateral perforation and dentine removal of the stainless steel K file and K3 rotary instrumentation in primary teeth. Materials and Methods Seventy-five primary molars were selected and divided into three groups. Using spiral computed tomography the teeth were scanned before instrumentation. Teeth were prepared using a stainless steel K file for manual technique. All the canals were prepared up to file size 35. In K3 rotary files (.02 taper) instrumentation was done up to 35 size file. In K3 rotary files (.04 taper) the instrumentation was done up to 25 size file and simultaneously the instrumentation time was recorded. The instrumented teeth were once again scanned and the images were compared with the images of the uninstrumented canals. Statistical Analysis Data was statistically analysed using Kruskal Wallis One-way ANOVA, Mann-Whitney U-Test and Pearson’s Chi-square Test. Results K3 rotary files (.02 taper) removed a significantly less amount of dentine, required less instrumentation time than a stainless steel K file. Conclusion K3 files (.02 taper) generated less dentine removal than the stainless steel K file and K3 files (.04 taper). K3 rotary files (.02 taper) were more effective for root canal instrumentation in primary teeth. PMID:26894166
Evaluation of a new filing system's ability to maintain canal morphology.
Thompson, Matthew; Sidow, Stephanie J; Lindsey, Kimberly; Chuang, Augustine; McPherson, James C
2014-06-01
The manufacturer of the Hyflex CM endodontic files claims the files remain centered within the canal, and if unwound during treatment, they will regain their original shape after sterilization. The purpose of this study was to evaluate and compare the canal centering ability of the Hyflex CM and the ProFile ISO filing systems after repeated uses in simulated canals, followed by autoclaving. Sixty acrylic blocks with a canal curvature of 45° were stained with methylene blue, photographed, and divided into 2 groups, H (Hyflex CM) and P (ProFile ISO). The groups were further subdivided into 3 subgroups: H1, H2, H3; P1, P2, P3 (n = 10). Groups H1 and P1 were instrumented to 40 (.04) with the respective file system. Used files were autoclaved for 26 minutes at 126°C. After sterilization, the files were used to instrument groups H2 and P2. The same sterilization and instrumentation procedure was repeated for groups H3 and P3. Post-instrumentation digital images were taken and superimposed over the pre-instrumentation images. Changes in the location of the center of the canal at predetermined reference points were recorded and compared within subgroups and between filing systems. Statistical differences in intergroup and intragroup transportation measures were analyzed by using the Kruskal-Wallis analysis of variance of ranks with the Bonferroni post hoc test. There was a difference between Hyflex CM and ProFile ISO groups, although it was not statistically significant. Intragroup differences for both Hyflex CM and ProFile ISO groups were not significant (P < .05). The Hyflex CM and ProFile ISO files equally maintained the original canal's morphology after 2 sterilization cycles. Published by Elsevier Inc.
Teaching the Dance Class: Strategies to Enhance Skill Acquisition, Mastery and Positive Self-Image
ERIC Educational Resources Information Center
Mainwaring, Lynda M.; Krasnow, Donna H.
2010-01-01
Effective teaching of dance skills is informed by a variety of theoretical frameworks and individual teaching and learning styles. The purpose of this paper is to present practical teaching strategies that enhance the mastery of skills and promote self-esteem, self-efficacy, and positive self-image. The predominant thinking and primary research…
O'Reilly, Michael K; Reese, Sven; Herlihy, Therese; Geoghegan, Tony; Cantwell, Colin P; Feeney, Robin N M; Jones, James F X
2016-01-01
For centuries, cadaveric dissection has been the touchstone of anatomy education. It offers a medical student intimate access to his or her first patient. In contrast to idealized artisan anatomical models, it presents the natural variation of anatomy in fine detail. However, a new teaching construct has appeared recently in which artificial cadavers are manufactured through three-dimensional (3D) printing of patient specific radiological data sets. In this article, a simple powder based printer is made more versatile to manufacture hard bones, silicone muscles and perfusable blood vessels. The approach involves blending modern approaches (3D printing) with more ancient ones (casting and lost-wax techniques). These anatomically accurate models can augment the approach to anatomy teaching from dissection to synthesis of 3D-printed parts held together with embedded rare earth magnets. Vascular simulation is possible through application of pumps and artificial blood. The resulting arteries and veins can be cannulated and imaged with Doppler ultrasound. In some respects, 3D-printed anatomy is superior to older teaching methods because the parts are cheap, scalable, they can cover the entire age span, they can be both dissected and reassembled and the data files can be printed anywhere in the world and mass produced. Anatomical diversity can be collated as a digital repository and reprinted rather than waiting for the rare variant to appear in the dissection room. It is predicted that 3D printing will revolutionize anatomy when poly-material printing is perfected in the early 21st century. © 2015 American Association of Anatomists.
NASA Technical Reports Server (NTRS)
Lawton, Pat
2004-01-01
The objective of this work was to support the design of improved IUE NEWSIPS high dispersion extraction algorithms. The purpose of this work was to evaluate use of the Linearized Image (LIHI) file versus the Re-Sampled Image (SIHI) file, evaluate various extraction, and design algorithms for evaluation of IUE High Dispersion spectra. It was concluded the use of the Re-Sampled Image (SIHI) file was acceptable. Since the Gaussian profile worked well for the core and the Lorentzian profile worked well for the wings, the Voigt profile was chosen for use in the extraction algorithm. It was found that the gamma and sigma parameters varied significantly across the detector, so gamma and sigma masks for the SWP detector were developed. Extraction code was written.
Evaluating the Effectiveness of the 2001-2002 NASA "Why?" Files Program
NASA Technical Reports Server (NTRS)
Pinelli, Thomas E.; Frank, Kari Lou; Lambert, Matthew A.
2002-01-01
This report contains the results of the evaluation conducted for the 2001-2002 NASA 'Why?' Files program that was conducted in March 2002. The analysis is based on the results of 139 surveys collected from educators registered for the program. Respondents indicated that (1) the programs in the series are aligned with the national mathematics, science, and technology standards; (2) the programs are developmentally (grade level) appropriate; and (3) the programs enhance and enrich the teaching and learning of mathematics, science, and technology.
ERIC Educational Resources Information Center
Åkerlund, Andreas
2015-01-01
This article analyses the teaching of Swedish language lecturers active in Germany during the first half of the twentieth century. It shows the centrality of literature and literary constructions and analyses images of Swedishness and the Swedish nation present in the teaching material of that time in relation to the national image present in…
Volcanoes of the Wrangell Mountains and Cook Inlet region, Alaska: selected photographs
Neal, Christina A.; McGimsey, Robert G.; Diggles, Michael F.
2001-01-01
Alaska is home to more than 40 active volcanoes, many of which have erupted violently and repeatedly in the last 200 years. This CD-ROM contains 97 digitized color 35-mm images which represent a small fraction of thousands of photographs taken by Alaska Volcano Observatory scientists, other researchers, and private citizens. The photographs were selected to portray Alaska's volcanoes, to document recent eruptive activity, and to illustrate the range of volcanic phenomena observed in Alaska. These images are for use by the interested public, multimedia producers, desktop publishers, and the high-end printing industry. The digital images are stored in the 'images' folder and can be read across Macintosh, Windows, DOS, OS/2, SGI, and UNIX platforms with applications that can read JPG (JPEG - Joint Photographic Experts Group format) or PCD (Kodak's PhotoCD (YCC) format) files. Throughout this publication, the image numbers match among the file names, figure captions, thumbnail labels, and other references. Also included on this CD-ROM are Windows and Macintosh viewers and engines for keyword searches (Adobe Acrobat Reader with Search). At the time of this publication, Kodak's policy on the distribution of color-management files is still unresolved, and so none is included on this CD-ROM. However, using the Universal Ektachrome or Universal Kodachrome transforms found in your software will provide excellent color. In addition to PhotoCD (PCD) files, this CD-ROM contains large (14.2'x19.5') and small (4'x6') screen-resolution (72 dots per inch; dpi) images in JPEG format. These undergo downsizing and compression relative to the PhotoCD images.
TOASTing Your Images With Montage
NASA Astrophysics Data System (ADS)
Berriman, G. Bruce; Good, John
2017-01-01
The Montage image mosaic engine is a scalable toolkit for creating science-grade mosaics of FITS files, according to the user's specifications of coordinates, projection, sampling, and image rotation. It is written in ANSI-C and runs on all common *nix-based platforms. The code is freely available and is released with a BSD 3-clause license. Version 5 is a major upgrade to Montage, and provides support for creating images that can be consumed by the World Wide Telescope (WWT). Montage treats the TOAST sky tessellation scheme, used by the WWT, as a spherical projection like those in the WCStools library. Thus images in any projection can be converted to the TOAST projection by Montage’s reprojection services. These reprojections can be performed at scale on high-performance platforms and on desktops. WWT consumes PNG or JPEG files, organized according to WWT’s tiling and naming scheme. Montage therefore provides a set of dedicated modules to create the required files from FITS images that contain the TOAST projection. There are two other major features of Version 5. It supports processing of HEALPix files to any projection in the WCS tools library. And it can be built as a library that can be called from other languages, primarily Python. http://montage.ipac.caltech.edu.GitHub download page: https://github.com/Caltech-IPAC/Montage.ASCL record: ascl:1010.036. DOI: dx.doi.org/10.5281/zenodo.49418 Montage is funded by the National Science Foundation under Grant Number ACI-1440620,
A clinically observed discrepancy between image-based and log-based MLC positions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neal, Brian, E-mail: bpn2p@virginia.edu; Ahmed, Mahmoud; Kathuria, Kunal
2016-06-15
Purpose: To present a clinical case in which real-time intratreatment imaging identified an multileaf collimator (MLC) leaf to be consistently deviating from its programmed and logged position by >1 mm. Methods: An EPID-based exit-fluence dosimetry system designed to prevent gross delivery errors was used to capture cine during treatment images. The author serendipitously visually identified a suspected MLC leaf displacement that was not otherwise detected. The leaf position as recorded on the EPID images was measured and log-files were analyzed for the treatment in question, the prior day’s treatment, and for daily MLC test patterns acquired on those treatment days.more » Additional standard test patterns were used to quantify the leaf position. Results: Whereas the log-file reported no difference between planned and recorded positions, image-based measurements showed the leaf to be 1.3 ± 0.1 mm medial from the planned position. This offset was confirmed with the test pattern irradiations. Conclusions: It has been clinically observed that log-file derived leaf positions can differ from their actual position by >1 mm, and therefore cannot be considered to be the actual leaf positions. This cautions the use of log-based methods for MLC or patient quality assurance without independent confirmation of log integrity. Frequent verification of MLC positions through independent means is a necessary precondition to trust log-file records. Intratreatment EPID imaging provides a method to capture departures from MLC planned positions.« less
Evaluating the Effectiveness of the 2002-2003 NASA SCIence Files(TM) Program
NASA Technical Reports Server (NTRS)
Pinelli, Thomas E.; Lambert, Matthew A.; Williams, Amy C.
2004-01-01
NASA SCIence Files (tm) is a research-, inquiry-, and standards-based, integrated mathematics, science, and technology series of 60-minute instructional distance learning (television and web-based) programs for students in grades 3-5. Respondents who evaluated the programs in the 2002-2003 NASA SCIence Files (tm) series reported that (1) they used the programs in the series; (2) the goals and objectives for the series were met; (3) the programs were aligned with the national mathematics, science, and technology standards; (4) the program content was developmentally appropriate for grade level; and (5) the programs in the series enhanced and enriched the teaching of mathematics, science, and technology.
Morgan, Karen L. M.
2016-08-01
In addition to the photographs, a Google Earth Keyhole Markup Language (KML) file is provided and can be used to view the images by clicking on the marker and then the thumbnail or the link below the thumbnail. The KML file was created using the photographic navigation files. This KML file can be found in the kml folder.
Portable document format file showing the surface models of cadaver whole body.
Shin, Dong Sun; Chung, Min Suk; Park, Jin Seo; Park, Hyung Seon; Lee, Sangho; Moon, Young Lae; Jang, Hae Gwon
2012-08-01
In the Visible Korean project, 642 three-dimensional (3D) surface models have been built from the sectioned images of a male cadaver. It was recently discovered that popular PDF file enables users to approach the numerous surface models conveniently on Adobe Reader. Purpose of this study was to present a PDF file including systematized surface models of human body as the beneficial contents. To achieve the purpose, fitting software packages were employed in accordance with the procedures. Two-dimensional (2D) surface models including the original sectioned images were embedded into the 3D surface models. The surface models were categorized into systems and then groups. The adjusted surface models were inserted to a PDF file, where relevant multimedia data were added. The finalized PDF file containing comprehensive data of a whole body could be explored in varying manners. The PDF file, downloadable freely from the homepage (http://anatomy.co.kr), is expected to be used as a satisfactory self-learning tool of anatomy. Raw data of the surface models can be extracted from the PDF file and employed for various simulations for clinical practice. The technique to organize the surface models will be applied to manufacture of other PDF files containing various multimedia contents.
Overview of the ASA24® Researcher Website
The ASA24 Researcher Website allows researchers, clinicians, and teachers to register to use the ASA24 system for research, clinical practice, or teaching; to manage logistics of data collection; and to obtain analytic output files.
BOREAS RSS-20 POLDER Radiance Images From the NASA C-130
NASA Technical Reports Server (NTRS)
Leroy, M.; Hall, Forrest G. (Editor); Nickeson, Jaime (Editor); Smith, David E. (Technical Monitor)
2000-01-01
These Boreal Ecosystem-Atmosphere Study (BOREAS) Remote Sensing Science (RSS)-20 data are a subset of images collected by the Polarization and Directionality of Earth's Reflectance (POLDER) instrument over tower sites in the BOREAS study areas during the intensive field campaigns (IFCs) in 1994. The POLDER images presented here from the NASA ARC C-130 aircraft are made available for illustration purposes only. The data are stored in binary image-format files. The POLDER radiance images are available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC). The data files are available on a CD-ROM (see document number 20010000884).
Zhao, Weizhao; Li, Xiping; Chen, Hairong; Manns, Fabrice
2012-01-01
Medical Imaging is a key training component in Biomedical Engineering programs. Medical imaging education is interdisciplinary training, involving physics, mathematics, chemistry, electrical engineering, computer engineering, and applications in biology and medicine. Seeking an efficient teaching method for instructors and an effective learning environment for students has long been a goal for medical imaging education. By the support of NSF grants, we developed the medical imaging teaching software (MITS) and associated dynamic assessment tracking system (DATS). The MITS/DATS system has been applied to junior and senior medical imaging classes through a hybrid teaching model. The results show that student's learning gain improved, particularly in concept understanding and simulation project completion. The results also indicate disparities in subjective perception between junior and senior classes. Three institutions are collaborating to expand the courseware system and plan to apply it to different class settings.
VizieR Online Data Catalog: Pinpointing the SMBH in NGC1052 (Baczko+, 2016)
NASA Astrophysics Data System (ADS)
Baczko, A.-K.; Schulz, R.; Kadler, M.; Ros, E.; Perucho, M.; Krichbaum, T. P.; Bock, M.; Bremer, M.; Grossberger, C.; Lindqvist, M.; Lobanov, A. P.; Mannheim, K.; Marti-Vidal, I.; Mueller, C.; Wilms, J.; Zensus, J. A.
2016-06-01
The source NGC1052 was observed with the GMVA at 86GHz in Oct. 2004. One naturally weighted and one uniformly weighted CLEAN-image as FITS-files (Fig. 1 and 2) and one tapered map with more weight to short baselines as FITS-file (Fig. 3). (2 data files).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Temple, Brian Allen; Armstrong, Jerawan Chudoung
This document is a mid-year report on a deliverable for the PYTHON Radiography Analysis Tool (PyRAT) for project LANL12-RS-107J in FY15. The deliverable is deliverable number 2 in the work package and is titled “Add the ability to read in more types of image file formats in PyRAT”. Right now PyRAT can only read in uncompressed TIF files (tiff files). It is planned to expand the file formats that can be read by PyRAT, making it easier to use in more situations. A summary of the file formats added include jpeg, jpg, png and formatted ASCII files.
Image Processing for Teaching.
ERIC Educational Resources Information Center
Greenberg, R.; And Others
1993-01-01
The Image Processing for Teaching project provides a powerful medium to excite students about science and mathematics, especially children from minority groups and others whose needs have not been met by traditional teaching. Using professional-quality software on microcomputers, students explore a variety of scientific data sets, including…
Jain, Niharika; Pawar, Ajinkya M.; Ukey, Piyush D.; Jain, Prashant K.; Thakur, Bhagyashree; Gupta, Abhishek
2017-01-01
Objectives: To compare the relative axis modification and canal concentricity after glide path preparation with 20/0.02 hand K-file (NITIFLEX®) and 20/0.04 rotary file (HyFlex™ CM) with subsequent instrumentation with 1.5 mm self-adjusting file (SAF). Materials and Methods: One hundred and twenty ISO 15, 0.02 taper, Endo Training Blocks (Dentsply Maillefer, Ballaigues, Switzerland) were acquired and randomly divided into following two groups (n = 60): group 1, establishing glide path till 20/0.02 hand K-file (NITIFLEX®) followed by instrumentation with 1.5 mm SAF; and Group 2, establishing glide path till 20/0.04 rotary file (HyFlex™ CM) followed by instrumentation with 1.5 mm SAF. Pre- and post-instrumentation digital images were processed with MATLAB R 2013 software to identify the central axis, and then superimposed using digital imaging software (Picasa 3.0 software, Google Inc., California, USA) taking five landmarks as reference points. Student's t-test for pairwise comparisons was applied with the level of significance set at 0.05. Results: Training blocks instrumented with 20/0.04 rotary file and SAF were associated less deviation in canal axis (at all the five marked points), representing better canal concentricity compared to those, in which glide path was established by 20/0.02 hand K-files followed by SAF instrumentation. Conclusion: Canal geometry is better maintained after SAF instrumentation with a prior glide path established with 20/0.04 rotary file. PMID:28855752
[Teamwork in teaching mental health in medical training].
Perrier de Benedetti, Cristina; Beker, Ester; Cimadoro, Ana; Pausa, Cristina; Quintana, Irene
2007-01-01
In this paper we describe the methodology of teaching learning process that permits integration of theory and practice for the transmission of the three fundamental pillars of Mental Health Programme: learning doctor patient relationship, situational diagnosis and team work. The number and diversity of students in each course is a challenge for the teacher, who sustains the idea that the doctor patient relationship is learned starting from the teacher student relationship. Like patients, each student is unique. We describe the method used: to divide students into groups, that throughout the year become working-teams with the intention of practicing Medicine with an interpersonal relationship concept (with the patient, his or her family, his social circle, with colleagues, nursery, assistants and institutions). Each unit is coordinated by a group teacher. They have periodic meetings with the students (in the Balint Junior groups' method). The students have to create the contents and participate in the dynamics of the classes. This methodology changes the traditional vision and the teacher has the function of an organizer and facilitator of learning. It includes: a. Group division, b. Preparation of a file, c. Workshop, d. Teaching and e. Evaluation Teaching learning is conducive to a facilitating atmosphere through different resources like story telling, diagrams, drawings, movies, literature, use of plastic, role playing, elaborating scenes, characters and the file, evidence of all the activities.
LAS - LAND ANALYSIS SYSTEM, VERSION 5.0
NASA Technical Reports Server (NTRS)
Pease, P. B.
1994-01-01
The Land Analysis System (LAS) is an image analysis system designed to manipulate and analyze digital data in raster format and provide the user with a wide spectrum of functions and statistical tools for analysis. LAS offers these features under VMS with optional image display capabilities for IVAS and other display devices as well as the X-Windows environment. LAS provides a flexible framework for algorithm development as well as for the processing and analysis of image data. Users may choose between mouse-driven commands or the traditional command line input mode. LAS functions include supervised and unsupervised image classification, film product generation, geometric registration, image repair, radiometric correction and image statistical analysis. Data files accepted by LAS include formats such as Multi-Spectral Scanner (MSS), Thematic Mapper (TM) and Advanced Very High Resolution Radiometer (AVHRR). The enhanced geometric registration package now includes both image to image and map to map transformations. The over 200 LAS functions fall into image processing scenario categories which include: arithmetic and logical functions, data transformations, fourier transforms, geometric registration, hard copy output, image restoration, intensity transformation, multispectral and statistical analysis, file transfer, tape profiling and file management among others. Internal improvements to the LAS code have eliminated the VAX VMS dependencies and improved overall system performance. The maximum LAS image size has been increased to 20,000 lines by 20,000 samples with a maximum of 256 bands per image. The catalog management system used in earlier versions of LAS has been replaced by a more streamlined and maintenance-free method of file management. This system is not dependent on VAX/VMS and relies on file naming conventions alone to allow the use of identical LAS file names on different operating systems. While the LAS code has been improved, the original capabilities of the system have been preserved. These include maintaining associated image history, session logging, and batch, asynchronous and interactive mode of operation. The LAS application programs are integrated under version 4.1 of an interface called the Transportable Applications Executive (TAE). TAE 4.1 has four modes of user interaction: menu, direct command, tutor (or help), and dynamic tutor. In addition TAE 4.1 allows the operation of LAS functions using mouse-driven commands under the TAE-Facelift environment provided with TAE 4.1. These modes of operation allow users, from the beginner to the expert, to exercise specific application options. LAS is written in C-language and FORTRAN 77 for use with DEC VAX computers running VMS with approximately 16Mb of physical memory. This program runs under TAE 4.1. Since TAE 4.1 is not a current version of TAE, TAE 4.1 is included within the LAS distribution. Approximately 130,000 blocks (65Mb) of disk storage space are necessary to store the source code and files generated by the installation procedure for LAS and 44,000 blocks (22Mb) of disk storage space are necessary for TAE 4.1 installation. The only other dependencies for LAS are the subroutine libraries for the specific display device(s) that will be used with LAS/DMS (e.g. X-Windows and/or IVAS). The standard distribution medium for LAS is a set of two 9track 6250 BPI magnetic tapes in DEC VAX BACKUP format. It is also available on a set of two TK50 tape cartridges in DEC VAX BACKUP format. This program was developed in 1986 and last updated in 1992.
NASA Technical Reports Server (NTRS)
Banks, David C.
1994-01-01
This talk features two simple and useful tools for digital image processing in the UNIX environment. They are xv and pbmplus. The xv image viewer which runs under the X window system reads images in a number of different file formats and writes them out in different formats. The view area supports a pop-up control panel. The 'algorithms' menu lets you blur an image. The xv control panel also activates the color editor which displays the image's color map (if one exists). The xv image viewer is available through the internet. The pbmplus package is a set of tools designed to perform image processing from within a UNIX shell. The acronym 'pbm' stands for portable bit map. Like xv, the pbm plus tool can convert images from and to many different file formats. The source code and manual pages for pbmplus are also available through the internet. This software is in the public domain.
Web-based document and content management with off-the-shelf software
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schuster, J
1999-03-18
This, then, is the current status of the project: Since we made the switch to Intradoc, we are now treating the project as a document and image management system. In reality, it could be considered a document and content management system since we can manage almost any file input to the system such as video or audio. At present, however, we are concentrating on images. As mentioned above, my CRADA funding was only targeted at including thumbnails of images in Intradoc. We still had to modify Intradoc so that it would compress images submitted to the system. All processing ofmore » files submitted to Intradoc is handled in what is called the Document Refinery. Even though MrSID created thumbnails in the process of compressing an image, work needed to be done to somehow build this capability into the Document Refinery. Therefore we made the decision to contract the Intradoc Engineering Team to perform this custom development work. To make Intradoc even more capable of handling images, we have also contracted for customization of the Document Refinery to accept Adobe PhotoShop and Illustrator file in their native format.« less
BOREAS RSS-14 Level-1 GOES-8 Visible, IR and Water Vapor Images
NASA Technical Reports Server (NTRS)
Hall, Forrest G. (Editor); Faysash, David; Cooper, Harry J.; Smith, Eric A.; Newcomer, Jeffrey A.
2000-01-01
The BOREAS RSS-14 team collected and processed several GOES-7 and GOES-8 image data sets that covered the BOREAS study region. The level-1 BOREAS GOES-8 images are raw data values collected by RSS-14 personnel at FSU and delivered to BORIS. The data cover 14-Jul-1995 to 21-Sep-1995 and 01-Jan-1996 to 03-Oct-1996. The data start out containing three 8-bit spectral bands and end up containing five 10-bit spectral bands. No major problems with the data have been identified. The data are contained in binary image format files. Due to the large size of the images, the level-1 GOES-8 data are not contained on the BOREAS CD-ROM set. An inventory listing file is supplied on the CD-ROM to inform users of what data were collected. The level-1 GOES-8 image data are available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC). See sections 15 and 16 for more information. The data files are available on a CD-ROM (see document number 20010000884).
Morgan, Karen L. M.
2015-09-14
In addition to the photographs, a Google Earth Keyhole Markup Language (KML) file is provided and can be used to view the images by clicking on the marker and then clicking on either the thumbnail or the link above the thumbnail. The KML files were created using the photographic navigation files. These KML files can be found in the kml folder.
Morgan, Karen L.M.; Krohn, M. Dennis; Peterson, Russell D.; Thompson, Philip R.; Subino, Janice A.
2015-01-01
Table 1 provides detailed information about the GPS location, image name, date, and time for each of the 3,381 photographs taken, along with links to each photograph. The photographs are organized into segments, also referred to as contact sheets, and represent approximately 5 minutes of flight time. In addition to the photographs, a Google Earth Keyhole Markup Language (KML) file is provided, which can be used to view the images by clicking on the marker and then clicking on either the thumbnail or the link above the thumbnail. The KML files were created using the photographic navigation files.
MINC 2.0: A Flexible Format for Multi-Modal Images.
Vincent, Robert D; Neelin, Peter; Khalili-Mahani, Najmeh; Janke, Andrew L; Fonov, Vladimir S; Robbins, Steven M; Baghdadi, Leila; Lerch, Jason; Sled, John G; Adalat, Reza; MacDonald, David; Zijdenbos, Alex P; Collins, D Louis; Evans, Alan C
2016-01-01
It is often useful that an imaging data format can afford rich metadata, be flexible, scale to very large file sizes, support multi-modal data, and have strong inbuilt mechanisms for data provenance. Beginning in 1992, MINC was developed as a system for flexible, self-documenting representation of neuroscientific imaging data with arbitrary orientation and dimensionality. The MINC system incorporates three broad components: a file format specification, a programming library, and a growing set of tools. In the early 2000's the MINC developers created MINC 2.0, which added support for 64-bit file sizes, internal compression, and a number of other modern features. Because of its extensible design, it has been easy to incorporate details of provenance in the header metadata, including an explicit processing history, unique identifiers, and vendor-specific scanner settings. This makes MINC ideal for use in large scale imaging studies and databases. It also makes it easy to adapt to new scanning sequences and modalities.
Drenth, B.J.; Grauch, V.J.S.; Bankey, Viki; New Sense Geophysics, Ltd.
2009-01-01
This report contains digital data, image files, and text files describing data formats and survey procedures for two high-resolution aeromagnetic surveys in south-central Colorado: one in the eastern San Luis Valley, Alamosa and Saguache Counties, and the other in the southern Upper Arkansas Valley, Chaffee County. In the San Luis Valley, the Great Sand Dunes survey covers a large part of Great Sand Dunes National Park and Preserve and extends south along the mountain front to the foot of Mount Blanca. In the Upper Arkansas Valley, the Poncha Springs survey covers the town of Poncha Springs and vicinity. The digital files include grids, images, and flight-line data. Several derivative products from these data are also presented as grids and images, including two grids of reduced-to-pole aeromagnetic data and data continued to a reference surface. Images are presented in various formats and are intended to be used as input to geographic information systems, standard graphics software, or map plotting packages.
Teaching Bibliometric Analysis and MS/DOS Commands.
ERIC Educational Resources Information Center
Dou, Henri; And Others
1988-01-01
Outlines the steps involved in bibliometric studies, and demonstrates the ability to execute simple studies on microcomputers by downloading files using only the capability of MS/DOS. Detailed illustrations of the MS/DOS commands used are provided. (eight references) (CLB)
Giuliani, Valentina; Cocchetti, Roberto; Pagavino, Gabriella
2008-11-01
The aim of this study was to evaluate the efficacy of the ProTaper Universal System rotary retreatment system and of Profile 0.06 and hand instruments (K-file) in the removal of root filling materials. Forty-two extracted single-rooted anterior teeth were selected. The root canals were enlarged with nickel-titanium (NiTi) rotary files, filled with gutta-percha and sealer, and randomly divided into 3 experimental groups. The filling materials were removed with solvent in conjunction with one of the following devices and techniques: the ProTaper Universal System for retreatment, ProFile 0.06, and hand instruments (K-file). The roots were longitudinally sectioned, and the image of the root surface was photographed. The images were captured in JPEG format; the areas of the remaining filling materials and the time required for removing the gutta-percha and sealer were calculated by using the nonparametric one-way Kruskal-Wallis test and Tukey-Kramer tests, respectively. The group that showed better results for removing filling materials was the ProTaper Universal System for retreatment files, whereas the group of ProFile rotary instruments yielded better root canal cleanliness than the hand instruments, even though there was no statistically significant difference. The ProTaper Universal System for retreatment and ProFile rotary instruments worked significantly faster than the K-file. The ProTaper Universal System for retreatment files left cleaner root canal walls than the K-file hand instruments and the ProFile Rotary instruments, although none of the devices used guaranteed complete removal of the filling materials. The rotary NiTi system proved to be faster than hand instruments in removing root filling materials.
PCDS as a tool in teaching and research at the University of Michigan
NASA Technical Reports Server (NTRS)
Abreu, V.
1986-01-01
The Space Physics Research Laboratory's (SPRL) use of the Pilot Climate Data System (PCDS) is discussed. For this purpose, a computer center was established to provide the hardware and software necessary to fully utilize existing data bases for research and teaching purposes. A schematic of the SPRL network is given. The core of the system consists of two VAX 11/750s and a VAX 8600, networked through ETHERNET to several LSI 11/23 microprocessors. Much of the system is used for external communications with major networks and data centers. A VAX 11/750 provides DECNET services through the SPAN network to the PCDS. A functional diagram of PCDS usage is given. The browsing capabilities of the PCDS are used to generate data files, which are later transferred to the SPRL center for further data manipulation and display. This mode of operation for classroom instruction will be used to effectively use terminals and to simplify usage of the data base. The Atmosphere Explorer data base has been used successfully in a similar manner in courses related to the thermosphere and ionosphere. The main motivation to access the PCDS was to complement research efforts related to the High Resolution Doppler Imager (HRDI), to be flown on the Upper Atmosphere Research Satellite (UARS).
Leonardi, Rosalia; Maiorana, Francesco; Giordano, Daniela
2008-06-01
Many of us use and maintain files on more than 1 computer--a desktop part of the time, and a notebook, a palmtop, or removable devices at other times. It can be easy to forget which device contains the latest version of a particular file, and time-consuming searches often ensue. One way to solve this problem is to use software that synchronizes the files. This allows users to maintain updated versions of the same file in several locations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phillion, D.
This code enables one to display, take line-outs on, and perform various transformations on an image created by an array of integer*2 data. Uncompressed eight-bit TIFF files created on either the Macintosh or the IBM PC may also be read in and converted to a 16 bit signed integer image. This code is designed to handle all the formates used for PDS (photo-densitometer) files at the Lawrence Livermore National Laboratory. These formats are all explained by the application code. The image may be zoomed infinitely and the gray scale mapping can be easily changed. Line-outs may be horizontal or verticalmore » with arbitrary width, angled with arbitrary end points, or taken along any path. This code is usually used to examine spectrograph data. Spectral lines may be identified and a polynomial fit from position to wavelength may be found. The image array can be remapped so that the pixels all have the same change of lambda width. It is not necessary to do this, however. Lineouts may be printed, saved as Cricket tab-delimited files, or saved as PICT2 files. The plots may be linear, semilog, or logarithmic with nice values and proper scientific notation. Typically, spectral lines are curved. By identifying points on these lines and fitting their shapes by polyn.« less
Collecting and Animating Online Satellite Images.
ERIC Educational Resources Information Center
Irons, Ralph
1995-01-01
Describes how to generate automated classroom resources from the Internet. Topics covered include viewing animated satellite weather images using file transfer protocol (FTP); sources of images on the Internet; shareware available for viewing images; software for automating image retrieval; procedures for animating satellite images; and storing…
Integration of Medical Imaging Including Ultrasound into a New Clinical Anatomy Curriculum
ERIC Educational Resources Information Center
Moscova, Michelle; Bryce, Deborah A.; Sindhusake, Doungkamol; Young, Noel
2015-01-01
In 2008 a new clinical anatomy curriculum with integrated medical imaging component was introduced into the University of Sydney Medical Program. Medical imaging used for teaching the new curriculum included normal radiography, MRI, CT scans, and ultrasound imaging. These techniques were incorporated into teaching over the first two years of the…
Upper Elementary Math Lessons: Case Studies of Real Teaching
ERIC Educational Resources Information Center
Graeber, Anna O.; Valli, Linda; Newton, Kristie Jones
2011-01-01
Engaging students in worthwhile learning requires more than a knowledge of underlying principles of good teaching. It demands considerable practice as well as images of what good teaching in particular situations and for particular purposes might look like. This volume provides these images. These cases were written from authentic, unrehearsed…
Developing Mirror Self Awareness in Students with Autism Spectrum Disorder
ERIC Educational Resources Information Center
Duff, Christine K.; Flattery, J. J., Jr.
2014-01-01
A teaching methodology and curriculum was designed to develop and increase positive self-awareness in students diagnosed with autism spectrum disorders (ASD). Joint attention (JA) strategies were first utilized to directly teach students about reflected mirror images, and then subsequently, to indirectly teach students about their reflected image.…
Teaching surgical skills using video internet communication in a resource-limited setting.
Autry, Amy M; Knight, Sharon; Lester, Felicia; Dubowitz, Gerald; Byamugisha, Josaphat; Nsubuga, Yosam; Muyingo, Mark; Korn, Abner
2013-07-01
To study the feasibility and acceptability of using video Internet communication to teach and evaluate surgical skills in a low-resource setting. This case-controlled study used video Internet communication for surgical skills teaching and evaluation. We randomized intern physicians rotating in the Obstetrics and Gynecology Department at Mulago Hospital at Makerere University in Kampala, Uganda, to the control arm (usual practice) or intervention arm (three video teaching sessions with University of California, San Francisco faculty). We made preintervention and postintervention videos of all interns tying knots using a small video camera and uploaded the files to a file hosting service that offers cloud storage. A blinded faculty member graded all of the videos. Both groups completed a survey at the end of the study. We randomized 18 interns with complete data for eight in the intervention group and seven in the control group. We found score improvement of 50% or more in six of eight (75%) interns in the intervention group compared with one of seven (14%) in the control group (P=.04). Scores declined in five of the seven (71%) controls but in none in the intervention group. Both intervention and control groups used attendings, colleagues, and the Internet as sources for learning about knot-tying. The control group was less likely to practice knot-tying than the intervention group. The trainees and the instructors felt this method of training was enjoyable and helpful. Remote teaching in low-resource settings, where faculty time is limited and access to visiting faculty is sporadic, is feasible, effective, and well-accepted by both learner and teacher. II.
76 FR 10405 - Federal Copyright Protection of Sound Recordings Fixed Before February 15, 1972
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-24
... file in either the Adobe Portable Document File (PDF) format that contains searchable, accessible text (not an image); Microsoft Word; WordPerfect; Rich Text Format (RTF); or ASCII text file format (not a..., comments may be delivered in hard copy. If hand delivered by a private party, an original [[Page 10406...
Evaluating the Effectiveness of the 2003-2004 NASA SCIence Files(trademark) Program
NASA Technical Reports Server (NTRS)
Caton, Randall H.; Ricles, Shannon S.; Pinelli, Thomas E.; Legg, Amy C.; Lambert, Matthew A.
2005-01-01
The NASA SCI Files is an Emmy award-winning series of instructional programs for grades 3-5. Produced by the NASA Center for Distance Learning, programs in the series are research-, inquiry-, standards-, teacher- and technology-based. Each NASA SCI Files program (1) integrates mathematics, science, and technology; (2) uses Problem-Based Learning (PBL) to enhance and enrich the teaching and learning of science; (3) emphasizes science as inquiry and the scientific method; (4) motivates students to become critical thinkers and active problem solvers; and (5) uses NASA research, facilities, and personnel to raise student awareness of careers and to exhibit the "real-world" application of mathematics, science, and technology. In April 2004, 1,500 randomly selected registered users of the NASA SCI Files were invited to complete a survey containing a series of questions. A total of 263 surveys were received. This report contains the quantitative and qualitative results of that survey.
Evaluating the Effectiveness of the 2000-2001 NASA "Why?" Files Program
NASA Technical Reports Server (NTRS)
Pinelli, Thomas E.; Frank, Kari Lou; Ashcroft, Scott B.; Williams, Amy C.
2002-01-01
NASA 'Why?' Files, a research and standards-based, Emmy-award winning series of 60-minute instructional programs for grades 3-5, introduces students to NASA; integrates mathematics, science, and technology by using Problem-Based Learning (PBL), scientific inquiry, and the scientific method; and motivates students to become critical thinkers and active problem solvers. All four 2000-2001 NASA 'Why?' Files programs include an instructional broadcast, a lesson guide, an interactive web site, plus numerous instructional resources. In March 2001, 1,000 randomly selected program registrants participated in a survey. Of these surveys, 185 (154 usable) met the established cut-off date. Respondents reported that (1) they used the four programs in the 2000-2001 NASA 'Why?' Files series; (2) series goals and objectives were met; (3) programs met national mathematics, science, and technology standards; (4) program content was developmentally appropriate for grade level; and (5) programs enhanced/enriched the teaching of mathematics, science, and technology.
Astrometrica: Astrometric data reduction of CCD images
NASA Astrophysics Data System (ADS)
Raab, Herbert
2012-03-01
Astrometrica is an interactive software tool for scientific grade astrometric data reduction of CCD images. The current version of the software is for the Windows 32bit operating system family. Astrometrica reads FITS (8, 16 and 32 bit integer files) and SBIG image files. The size of the images is limited only by available memory. It also offers automatic image calibration (Dark Frame and Flat Field correction), automatic reference star identification, automatic moving object detection and identification, and access to new-generation star catalogs (PPMXL, UCAC 3 and CMC-14), in addition to online help and other features. Astrometrica is shareware, available for use for a limited period of time (100 days) for free; special arrangements can be made for educational projects.
A Study of NetCDF as an Approach for High Performance Medical Image Storage
NASA Astrophysics Data System (ADS)
Magnus, Marcone; Coelho Prado, Thiago; von Wangenhein, Aldo; de Macedo, Douglas D. J.; Dantas, M. A. R.
2012-02-01
The spread of telemedicine systems increases every day. The systems and PACS based on DICOM images has become common. This rise reflects the need to develop new storage systems, more efficient and with lower computational costs. With this in mind, this article discusses a study for application in NetCDF data format as the basic platform for storage of DICOM images. The study case comparison adopts an ordinary database, the HDF5 and the NetCDF to storage the medical images. Empirical results, using a real set of images, indicate that the time to retrieve images from the NetCDF for large scale images has a higher latency compared to the other two methods. In addition, the latency is proportional to the file size, which represents a drawback to a telemedicine system that is characterized by a large amount of large image files.
Real and Virtual Images Using a Classroom Hologram.
ERIC Educational Resources Information Center
Olson, Dale W.
1992-01-01
Describes the design and fabrication of a classroom hologram and activities utilizing the hologram to teach the concepts of real and virtual images to high school and introductory college students. Contrasts this method with three other approaches to teach about images. (MDH)
Tu, Ming-Gene; Chen, San-Yue; Huang, Heng-Li; Tsai, Chi-Cheng
2008-05-01
Preparing a continuous tapering conical shape and maintaining the original shape of a canal are obligatory in root canal preparation. The purpose of this study was to compare the shaping performance in simulated curved canal resin blocks of the same novice dental students using hand-prepared and engine-driven nickel-titanium (NiTi) rotary ProTaper instruments in an endodontic laboratory class. Twenty-three fourth-year dental students attending China Medical University Dental School prepared 46 simulated curved canals in resin blocks with two types of NiTi rotary systems: hand and motor ProTaper files. Composite images were prepared for estimation. Material removed, canal width and canal deviation were measured at five levels in the apical 4 mm of the simulated curved canals using AutoCAD 2004 software. Data were analyzed using Wilcoxon's rank-sum test. The hand ProTaper group cut significantly wider than the motor rotary ProTaper group in the outer wall, except for the apical 0 mm point. The total canal width was cut significantly larger in the hand group than in the motor group. There was no significant difference between the two groups in centering canal shape, except at the 3 mm level. These findings show that the novice students prepared the simulated curved canal that deviated more outwardly from apical 1 mm to 4 mm using the hand ProTaper. The ability to maintain the original curvature was better in the motor rotary ProTaper group than in the hand ProTaper group. Undergraduate students, if following the preparation sequence carefully, could successfully perform canal shaping by motor ProTaper files and achieve better root canal geometry than by using hand ProTaper files within the same teaching and practicing sessions.
East Asian Cinema (College Course File).
ERIC Educational Resources Information Center
Ehrlich, Linda; Ma, Ning
1990-01-01
Provides guidelines for instructors who teach entire courses on (or who include) films from Japan and China. Considers issues of concern in contemporary Asian cinema such as conflicts between tradition and modernity, indigenous definitions of cultural identity and artistic form, and internationalization. (KEH)
Miller, John J.; Agena, W.F.; Lee, M.W.; Zihlman, F.N.; Grow, J.A.; Taylor, D.J.; Killgore, Michele; Oliver, H.L.
2000-01-01
This CD-ROM contains stacked, migrated, 2-Dimensional seismic reflection data and associated support information for 22 regional seismic lines (3,470 line-miles) recorded in the National Petroleum Reserve ? Alaska (NPRA) from 1974 through 1981. Together, these lines constitute about one-quarter of the seismic data collected as part of the Federal Government?s program to evaluate the petroleum potential of the Reserve. The regional lines, which form a grid covering the entire NPRA, were created by combining various individual lines recorded in different years using different recording parameters. These data were reprocessed by the USGS using modern, post-stack processing techniques, to create a data set suitable for interpretation on interactive seismic interpretation computer workstations. Reprocessing was done in support of ongoing petroleum resource studies by the USGS Energy Program. The CD-ROM contains the following files: 1) 22 files containing the digital seismic data in standard, SEG-Y format; 2) 1 file containing navigation data for the 22 lines in standard SEG-P1 format; 3) 22 small scale graphic images of each seismic line in Adobe Acrobat? PDF format; 4) a graphic image of the location map, generated from the navigation file, with hyperlinks to the graphic images of the seismic lines; 5) an ASCII text file with cross-reference information for relating the sequential trace numbers on each regional line to the line number and shotpoint number of the original component lines; and 6) an explanation of the processing used to create the final seismic sections (this document). The SEG-Y format seismic files and SEG-P1 format navigation file contain all the information necessary for loading the data onto a seismic interpretation workstation.
Govsa, Figen; Yagdi, Tahir; Ozer, Mehmet Asim; Eraslan, Cenk; Alagoz, Ahmet Kemal
2017-02-01
The purpose of this study is to recreate live patient arterial anomalies using new recent application of three-dimensional (3D) printed anatomical models. Another purpose of building such models is to evaluate the effectiveness of angiographic data. With the help of the DICOM files from computed tomographic angiography (CT-A), we were able to build a printed model of variant course of the internal carotid artery (ICA). Images of coiling of the ICA taken by CT-A, were then converted into 3D images using Google SketchUp free software, and the images were saved in stereolithography format. Imaging helped us conduct the examination in details with reference to geometrical features of ICA, degree of curve, its extension, location and presence of loop. Challenging vascular anatomy was exposed with models of adverse curve of carotid anatomy, including highly angulated necks, conical necks, short necks, tortuous carotid arteries, and narrowed carotid lumens. It assisted us to comprehend spatial anatomy configuration of life-like models. 3D model can be very effective in cases when anatomical difficulties are detected through the CT-A, and therefore, a tactile approach is demanded preoperatively. 3D life-like models serve as an essential office-based tool in vascular surgery as they assist surgeons in preoperative planning, develop intraoperative guidance, teach both the patients and the surgical trainees, and simulate to show patient-specific procedures in medical field.
Insights on WWW-based geoscience teaching: Climbing the first year learning cliff
NASA Astrophysics Data System (ADS)
Lamberson, Michelle N.; Johnson, Mark; Bevier, Mary Lou; Russell, J. Kelly
1997-06-01
In early 1995, The University of British Columbia Department of Geological Sciences (now Earth and Ocean Sciences) initiated a project that explored the effectiveness of the World Wide Web as a teaching and learning medium. Four decisions made at the onset of the project have guided the department's educational technology plan: (1) over 90% of funding recieved from educational technology grants was committed towards personnel; (2) materials developed are modular in design; (3) a data-base approach was taken to resource development; and (4) a strong commitment to student involvement in courseware development. The project comprised development of a web site for an existing core course: Geology 202, Introduction to Petrology. The web site is a gateway to course information, content, resources, exercises, and several searchable data-bases (images, petrologic definitions, and minerals in thin section). Material was developed on either an IBM or UNIX machine, ported to a UNIX platform, and is accessed using the Netscape browser. The resources consist primarily of HTML files or CGI scripts with associated text, images, sound, digital movies, and animations. Students access the web site from the departmental student computer facility, from home or a computer station in the petrology laboratory. Results of a survey of the Geol 202 students indicate that they found the majority of the resources useful, and the site is being expanded. The Geology 202 project had a "trickle-up" effect throughout the department: prior to this project, there was minimal use of Internet resources in lower-level geology courses. By the end of the 1996-1997 academic year, we anticipate that at least 17 Earth and Ocean Science courses will have a WWW site for one or all of the following uses: (1) presenting basic information; (2) accessing lecture images; (3) providing a jumping-off point for exploring related WWW sites; (4) conducting on-line exercises; and/or (5) providing a communications forum for students and faculty via a Hypernews group. Url http://www.science.ubc.ca/
NASA Astrophysics Data System (ADS)
Zhang, Xiaofen; Clements, M. A. (Ken); Ellerton, Nerida F.
2015-06-01
This study investigated how fifth-grade children's concept images of the unit fractions represented by the symbols , , and changed as a result of their participation in an instructional intervention based on multiple embodiments of fraction concepts. The participants' concept images were examined through pre- and post-teaching written questions and pre- and post-teaching one-to-one verbal interview questions. Results showed that at the pre-teaching stage, the student concept images of unit fractions were very narrow and mainly linked to area models. However, after the instructional intervention, the fifth graders were able to select and apply a variety of models in response to unit fraction tasks, and their concept images of unit fractions were enriched and linked to capacity, perimeter, linear and discrete models, as well as to area models. Their performances on tests had improved, and their conceptual understandings of unit fractions had developed.
NASA Technical Reports Server (NTRS)
Malin, Michael; Revine, Michael; Boyce, Joseph M. (Technical Monitor)
1998-01-01
This compact disk (CD) is part of the Clementine I high resolution (HiRes) camera lunar image mosaics developed by Malin Space Science Systems (MSSS). These mosaics were developed through calibration and semi-automated registration against the recently released geometrically and photometrically controlled Ultraviolet/Visible (UV/Vis) Basemap Mosaic, which is available through the PDS, as CD-ROM volumes CL_3001-3015. The HiRes mosaics are compiled from non-uniformity corrected, 750 nanometer ("D") filter high resolution observations from the HiRes imaging system onboard the Clementine Spacecraft. The geometric control is provided by the U. S. Geological Survey (USGS) Clementine Basemap Mosaic compiled from the 750 nm Ultraviolet/Visible Clementine imaging system. Calibration was achieved by removing the image nonuniformity largely caused by the HiRes system's light intensifier. Also provided are offset and scale factors, achieved by a fit of the HiRes data to the corresponding photometrically calibrated UV/Vis basemap that approximately transform the 8-bit HiRes data to photometric units. The mosaics on this CD are compiled from polar data (latitudes greater than 80 degrees), and are presented in the stereographic projection at a scale of 30 m/pixel at the pole, a resolution 5 times greater than that (150 m/pixel) of the corresponding UV/Vis polar basemap. This 5:1 scale ratio is in keeping with the sub-polar mosaic, in which the HiRes and UV/Vis mosaics had scales of 20 m/pixel and 100 m/pixel, respectively. The equal-area property of the stereographic projection made this preferable for the HiRes polar mosaic rather than the basemap's orthographic projection. Thus, a necessary first step in constructing the mosaic was the reprojection of the UV/Vis basemap to the stereographic projection. The HiRes polar data can be naturally grouped according to the orbital periapsis, which was in the south during the first half of the mapping mission and in the north during the second half. Images in each group have generally uniform intrinsic resolution, illumination, exposure and gain. Rather than mingle data from the two periapsis epochs, separate mosaics are provided for each, a total of 4 polar mosaics. The mosaics are divided into 100 square tiles of 2250 pixels (approximately 2.2 deg near the pole) on a side. Not all squares of this grid contain HiRes mosaic data, some inevitably since a square is not a perfect representation of a (latitude) circle, others due to the lack of HiRes data. This CD also contains ancillary data files that support the HiRes mosaic. These files include browse images with UV/Vis context stored in a Joint Photographic Experts Group (JPEG) format, index files ('imgindx.tab' and 'srcindx.tab') that tabulate the contents of the CD, and documentation files. For more information on the contents and organization of the CD volume set refer to the "FILES, DIRECTORIES AND DISK CONTENTS" section of this document. The image files are organized according to NASA's Planetary Data System (PDS) standards. An image file (tile) is organized as a PDS labeled file containing an "image object".
Workflow opportunities using JPEG 2000
NASA Astrophysics Data System (ADS)
Foshee, Scott
2002-11-01
JPEG 2000 is a new image compression standard from ISO/IEC JTC1 SC29 WG1, the Joint Photographic Experts Group (JPEG) committee. Better thought of as a sibling to JPEG rather than descendant, the JPEG 2000 standard offers wavelet based compression as well as companion file formats and related standardized technology. This paper examines the JPEG 2000 standard for features in four specific areas-compression, file formats, client-server, and conformance/compliance that enable image workflows.
PySE: Python Source Extractor for radio astronomical images
NASA Astrophysics Data System (ADS)
Spreeuw, Hanno; Swinbank, John; Molenaar, Gijs; Staley, Tim; Rol, Evert; Sanders, John; Scheers, Bart; Kuiack, Mark
2018-05-01
PySE finds and measures sources in radio telescope images. It is run with several options, such as the detection threshold (a multiple of the local noise), grid size, and the forced clean beam fit, followed by a list of input image files in standard FITS or CASA format. From these, PySe provides a list of found sources; information such as the calculated background image, source list in different formats (e.g. text, region files importable in DS9), and other data may be saved. PySe can be integrated into a pipeline; it was originally written as part of the LOFAR Transient Detection Pipeline (TraP, ascl:1412.011).
EROS main image file - A picture perfect database for Landsat imagery and aerial photography
NASA Technical Reports Server (NTRS)
Jack, R. F.
1984-01-01
The Earth Resources Observation System (EROS) Program was established by the U.S. Department of the Interior in 1966 under the administration of the Geological Survey. It is primarily concerned with the application of remote sensing techniques for the management of natural resources. The retrieval system employed to search the EROS database is called INORAC (Inquiry, Ordering, and Accounting). A description is given of the types of images identified in EROS, taking into account Landsat imagery, Skylab images, Gemini/Apollo photography, and NASA aerial photography. Attention is given to retrieval commands, geographic coordinate searching, refinement techniques, various online functions, and questions regarding the access to the EROS Main Image File.
Morgan, Karen L. M.; Krohn, M. Dennis; Guy, Kristy K.
2015-01-01
In addition to the photographs, a Google Earth Keyhole Markup Language (KML) file is provided and can be used to view the images by clicking on the marker and then clicking on either the thumbnail or the link above the thumbnail. The KML files were created using the photographic navigation files.
Morgan, Karen L. M.
2015-08-31
In addition to the photographs, a Google Earth Keyhole Markup Language (KML) file is provided and can be used to view the images by clicking on the marker and then clicking on either the thumbnail or the link above the thumbnail. The KML files were created using the photographic navigation files.
Indexing and filing of pathological illustrations.
Brown, R A; Fawkes, R S; Beck, J S
1975-01-01
An inexpensive feature card retrieval system has been combined with the Systematised Nomenclature of Pathology (SNOP) to provide simple but efficient means of indexing and filing 2 in. x 2 in. transparencies within a department of pathology. Using this system 2400 transparencies and the associated index cards can be conveniently stored in one drawer of a standard filing cabinet. Images PMID:1123438
ERIC Educational Resources Information Center
Bruley, Karina
1996-01-01
Provides a checklist of considerations for installing document image processing with an electronic document management system. Other topics include scanning; indexing; the image file life cycle; benefits of imaging; document-driven workflow; and planning for workplace changes like postsorting, creating a scanning room, redeveloping job tasks and…
Visualization Tools for Lattice QCD - Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Massimo Di Pierro
2012-03-15
Our research project is about the development of visualization tools for Lattice QCD. We developed various tools by extending existing libraries, adding new algorithms, exposing new APIs, and creating web interfaces (including the new NERSC gauge connection web site). Our tools cover the full stack of operations from automating download of data, to generating VTK files (topological charge, plaquette, Polyakov lines, quark and meson propagators, currents), to turning the VTK files into images, movies, and web pages. Some of the tools have their own web interfaces. Some Lattice QCD visualization have been created in the past but, to our knowledge,more » our tools are the only ones of their kind since they are general purpose, customizable, and relatively easy to use. We believe they will be valuable to physicists working in the field. They can be used to better teach Lattice QCD concepts to new graduate students; they can be used to observe the changes in topological charge density and detect possible sources of bias in computations; they can be used to observe the convergence of the algorithms at a local level and determine possible problems; they can be used to probe heavy-light mesons with currents and determine their spatial distribution; they can be used to detect corrupted gauge configurations. There are some indirect results of this grant that will benefit a broader audience than Lattice QCD physicists.« less
Retrieving high-resolution images over the Internet from an anatomical image database
NASA Astrophysics Data System (ADS)
Strupp-Adams, Annette; Henderson, Earl
1999-12-01
The Visible Human Data set is an important contribution to the national collection of anatomical images. To enhance the availability of these images, the National Library of Medicine has supported the design and development of a prototype object-oriented image database which imports, stores, and distributes high resolution anatomical images in both pixel and voxel formats. One of the key database modules is its client-server Internet interface. This Web interface provides a query engine with retrieval access to high-resolution anatomical images that range in size from 100KB for browser viewable rendered images, to 1GB for anatomical structures in voxel file formats. The Web query and retrieval client-server system is composed of applet GUIs, servlets, and RMI application modules which communicate with each other to allow users to query for specific anatomical structures, and retrieve image data as well as associated anatomical images from the database. Selected images can be downloaded individually as single files via HTTP or downloaded in batch-mode over the Internet to the user's machine through an applet that uses Netscape's Object Signing mechanism. The image database uses ObjectDesign's object-oriented DBMS, ObjectStore that has a Java interface. The query and retrieval systems has been tested with a Java-CDE window system, and on the x86 architecture using Windows NT 4.0. This paper describes the Java applet client search engine that queries the database; the Java client module that enables users to view anatomical images online; the Java application server interface to the database which organizes data returned to the user, and its distribution engine that allow users to download image files individually and/or in batch-mode.
Our path to a filmless future.
Adair, Luther; Ledermann, Eric
2012-02-01
Film-based radiographs are still being used to teach in a conference format, which presents several viewing challenges amongst other problems. In the age of cloud computing, which enables the use of online server storage space, this information could be used more effectively if it were digitized. However, digitizing film-based radiographs and making them available for use in the cloud is not as easy as it seems. In order to address the issue of digitizing the film-based radiograph libraries in our radiology department, we looked at several options. The option that we chose was a consumer-grade scanner, and this decision was based on price, resolution, shades of gray, built-in transparency function, and its physical attributes. Our goal was to digitize the film-based radiograph teaching files so they could be stored in a digital file locker such as Google Picassa for organization and quick access later. These files would constantly be updated in a Google document by residents, and this document would be called the "Living Document" based on its continuous expandability. This method would allow even the smallest radiology department to benefit from the use of modern technology to gain access to valuable information stored in film-based radiographs and give every resident the opportunity to benefit from it.
Teaching Effectively with Visual Effect in an Image-Processing Class.
ERIC Educational Resources Information Center
Ng, G. S.
1997-01-01
Describes a course teaching the use of computers in emulating human visual capability and image processing and proposes an interactive presentation using multimedia technology to capture and sustain student attention. Describes the three phase presentation: introduction of image processing equipment, presentation of lecture material, and…
78 FR 17233 - Notice of Opportunity To File Amicus Briefs
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-20
.... Any commonly-used word processing format or PDF format is acceptable; text formats are preferable to image formats. Briefs may also be filed with the Office of the Clerk of the Board, Merit Systems...
Centralized Accounting and Electronic Filing Provides Efficient Receivables Collection.
ERIC Educational Resources Information Center
School Business Affairs, 1983
1983-01-01
An electronic filing system makes financial control manageable at Bowling Green State University, Ohio. The system enables quick access to computer-stored consolidated account data and microfilm images of charges, statements, and other billing documents. (MLF)
Woodson, Kristina E; Sable, Craig A; Cross, Russell R; Pearson, Gail D; Martin, Gerard R
2004-11-01
Live transmission of echocardiograms over integrated services digital network lines is accurate and has led to improvements in the delivery of pediatric cardiology care. Permanent archiving of the live studies has not previously been reported. Specific obstacles to permanent storage of telemedicine files have included the ability to produce accurate images without a significant increase in storage requirements. We evaluated the accuracy of Motion Pictures Expert Group (MPEG) digitization of incoming video streams and assessed the storage requirements of these files for infants in a real-time pediatric tele-echocardiography program. All major cardiac diagnoses were correctly diagnosed by review of MPEG images. MPEG file size ranged from 11.1 to 182 MB (56.5 +/- 29.9 MB). MPEG digitization during live neonatal telemedicine is accurate and provides an efficient method for storage. This modality has acceptable storage requirements; file sizes are comparable to other digital modalities.
Gutman, David A.; Dunn, William D.; Cobb, Jake; Stoner, Richard M.; Kalpathy-Cramer, Jayashree; Erickson, Bradley
2014-01-01
Advances in web technologies now allow direct visualization of imaging data sets without necessitating the download of large file sets or the installation of software. This allows centralization of file storage and facilitates image review and analysis. XNATView is a light framework recently developed in our lab to visualize DICOM images stored in The Extensible Neuroimaging Archive Toolkit (XNAT). It consists of a PyXNAT-based framework to wrap around the REST application programming interface (API) and query the data in XNAT. XNATView was developed to simplify quality assurance, help organize imaging data, and facilitate data sharing for intra- and inter-laboratory collaborations. Its zero-footprint design allows the user to connect to XNAT from a web browser, navigate through projects, experiments, and subjects, and view DICOM images with accompanying metadata all within a single viewing instance. PMID:24904399
VizieR Online Data Catalog: PN and HII regions of West and East of NGC 3109 (Pena+, 2007)
NASA Astrophysics Data System (ADS)
Pena, M.; Richer, M. G.; Stasińska, G.
2007-03-01
Six files (fits format, 16MB) containing images of the West (W) and East (E) zones of NGC 3109 are presented. The images are a combination of frames obtained with the ESO Very Large Telescope and the Focal Reducer Spectrograph FORS1. All the frames were obtained on 29 November and 1 December 2005, with air masses smaller than 1.16 and seeing better than 0.7 arcsec. They constitute the pre-imaging of the ESO program ID 076.B-0166(A). Central coordinates of images are: West side (images named NGC3109W-xxxx.fits) RA=10:02:54.5, DE=-26:09:22, equinox 2000. East side (images named NGC3109E-xxx.fits) RA=10:03:19.8, DE=-26:09:32, equinox 2000. The image size is 6.8x6.8arcmin2. (3 data files).
NASA Astrophysics Data System (ADS)
Zaborowicz, M.; Przybył, J.; Koszela, K.; Boniecki, P.; Mueller, W.; Raba, B.; Lewicki, A.; Przybył, K.
2014-04-01
The aim of the project was to make the software which on the basis on image of greenhouse tomato allows for the extraction of its characteristics. Data gathered during the image analysis and processing were used to build learning sets of artificial neural networks. Program enables to process pictures in jpeg format, acquisition of statistical information of the picture and export them to an external file. Produced software is intended to batch analyze collected research material and obtained information saved as a csv file. Program allows for analysis of 33 independent parameters implicitly to describe tested image. The application is dedicated to processing and image analysis of greenhouse tomatoes. The program can be used for analysis of other fruits and vegetables of a spherical shape.
Open-loop measurement of data sampling point for SPM
NASA Astrophysics Data System (ADS)
Wang, Yueyu; Zhao, Xuezeng
2006-03-01
SPM (Scanning Probe Microscope) provides "three-dimensional images" with nanometer level resolution, and some of them can be used as metrology tools. However, SPM's images are commonly distorted by non-ideal properties of SPM's piezoelectric scanner, which reduces metrological accuracy and data repeatability. In order to eliminate this limit, an "open-loop sampling" method is presented. In this method, the positional values of sampling points in all three directions on the surface of the sample are measured by the position sensor and recorded in SPM's image file, which is used to replace the image file from a conventional SPM. Because the positions in X and Y directions are measured at the same time of sampling height information in Z direction, the image distortion caused by scanner locating error can be reduced by proper image processing algorithm.
Add Variety of Production Typewriting
ERIC Educational Resources Information Center
Clippinger, Dorinda A.
1974-01-01
To encourage and motivate students and to provide variety in the advanced typewriting class, the following suggestions are offered: have the introduction to production lessons on tape, teach desk organization, have students maintain carbon copy files, dictate instructions, and keep a typewriting reference manual. (AG)
34 CFR 682.509 - Special conditions for filing a claim.
Code of Federal Regulations, 2011 CFR
2011-07-01
... in § 682.511(e)(3), if— (1) In the case of a loan that was not made or originated by the school, the lender learns that while the student was enrolled at the school the school terminated its teaching...
Steno-Clerical Curriculum Guide.
ERIC Educational Resources Information Center
Michigan State Univ., East Lansing. Coll. of Agriculture and Natural Resources Education Inst.
This curriculum guide consists of materials for use in teaching a competency-based course to prepare students for employment in secretarial and clerical occupations. The instructional program prepares students to record and transcribe communications, provide administrative support, and abstract, classify, and file information. The first part of…
Five years of experience teaching pathology to dental students using the WebMicroscope
2011-01-01
Background We describe development and evaluation of the user-friendly web based virtual microscopy - WebMicroscope for teaching and learning dental students basic and oral pathology. Traditional students microscopes were replaced by computer workstations. Methods The transition of the basic and oral pathology courses from light to virtual microscopy has been completed gradually over a five-year period. A pilot study was conducted in academic year 2005/2006 to estimate the feasibility of integrating virtual microscopy into a traditional light microscopy-based pathology course. The entire training set of glass slides was subsequently converted to virtual slides and placed on the WebMicroscope server. Giving access to fully digitized slides on the web with a browser and a viewer plug-in, the computer has become a perfect companion of the student. Results The study material consists now of over 400 fully digitized slides which covering 15 entities in basic and systemic pathology and 15 entities in oral pathology. Digitized slides are linked with still macro- and microscopic images, organized with clinical information into virtual cases and supplemented with text files, syllabus, PowerPoint presentations and animations on the web, serving additionally as material for individual studies. After their examinations, the students rated the use of the software, quality of the images, the ease of handling the images, and the effective use of virtual slides during the laboratory practicals. Responses were evaluated on a standardized scale. Because of the positive opinions and support from the students, the satisfaction surveys had shown a progressive improvement over the past 5 years. The WebMicroscope as a didactic tool for laboratory practicals was rated over 8 on a 1-10 scale for basic and systemic pathology and 9/10 for oral pathology especially as various students’ suggestions were implemented. Overall, the quality of the images was rated as very good. Conclusions An overwhelming majority of our students regarded a possibility of using virtual slides at their convenience as highly desirable. Our students and faculty consider the use of the virtual microscope for the study of basic as well as oral pathology as a significant improvement over the light microscope. PMID:21489183
Imaging Systems: What, When, How.
ERIC Educational Resources Information Center
Lunin, Lois F.; And Others
1992-01-01
The three articles in this special section on document image files discuss intelligent character recognition, including comparison with optical character recognition; selection of displays for document image processing, focusing on paperlike displays; and imaging hardware, software, and vendors, including guidelines for system selection. (MES)
Distributed Storage Algorithm for Geospatial Image Data Based on Data Access Patterns.
Pan, Shaoming; Li, Yongkai; Xu, Zhengquan; Chong, Yanwen
2015-01-01
Declustering techniques are widely used in distributed environments to reduce query response time through parallel I/O by splitting large files into several small blocks and then distributing those blocks among multiple storage nodes. Unfortunately, however, many small geospatial image data files cannot be further split for distributed storage. In this paper, we propose a complete theoretical system for the distributed storage of small geospatial image data files based on mining the access patterns of geospatial image data using their historical access log information. First, an algorithm is developed to construct an access correlation matrix based on the analysis of the log information, which reveals the patterns of access to the geospatial image data. Then, a practical heuristic algorithm is developed to determine a reasonable solution based on the access correlation matrix. Finally, a number of comparative experiments are presented, demonstrating that our algorithm displays a higher total parallel access probability than those of other algorithms by approximately 10-15% and that the performance can be further improved by more than 20% by simultaneously applying a copy storage strategy. These experiments show that the algorithm can be applied in distributed environments to help realize parallel I/O and thereby improve system performance.
ERIC Educational Resources Information Center
Greenberg, Richard
1998-01-01
Describes the Image Processing for Teaching (IPT) project which provides digital image processing to excite students about science and mathematics as they use research-quality software on microcomputers. Provides information on IPT whose components of this dissemination project have been widespread teacher education, curriculum-based materials…
ERIC Educational Resources Information Center
Saputri, Affa Ardhi; Wilujeng, Insih
2017-01-01
This research aims at revealing (1) the suitability of physics e-scaffolding teaching media with mathematical and image/diagrammatic representation, as well as (2) the effectiveness of the e-scaffolding teaching media with mathematical and image/diagrammatic representation to improve students' problem solving ability and scientific attitude. It is…
A Review of Aeromagnetic Anomalies in the Sawatch Range, Central Colorado
Bankey, Viki
2010-01-01
This report contains digital data and image files of aeromagnetic anomalies in the Sawatch Range of central Colorado. The primary product is a data layer of polygons with linked data records that summarize previous interpretations of aeromagnetic anomalies in this region. None of these data files and images are new; rather, they are presented in updated formats that are intended to be used as input to geographic information systems, standard graphics software, or map-plotting packages.
Exploring podcasting in heredity and evolution teaching.
Almeida-Aguiar, Cristina; Carvalho, Ana Amélia
2016-09-10
Podcasts are digital files very popular in several and very distinct areas. In higher education, they have been explored in a multitude of ways mainly to support teaching and learning processes. The study here described focuses the integration of podcasts in Heredity and Evolution, a course from the Biology and Geology Degree Program at University of Minho, Portugal. It aimed to introduce podcasts in the teaching/learning context, to empirically study different dimensions of podcasting, and to evaluate students' acceptance and receptiveness to the pedagogical use of this technology. Five informative podcasts and three with feedback were produced and delivered. All the students listened to the audio files and considered the episodes audible and clear, their preference going to episodes of short or moderate length and containing summaries, study guidelines or syllabus contents. Students judged extremely valuable the integration of this technology in learning and showed receptiveness to podcasting in other courses. Curiously, in spite of owning mobile devices, students clearly favored the use of personal computers to listen to the podcasts. This student acceptance and openness to podcasting has been encouraging its pedagogical application in other teaching courses. The episodes produced often maintain the characteristics identified as the best by the students of this study but the pedagogical approach has been moving to a more student-centered learning situation, with students as podcasts producers. © 2016 by The International Union of Biochemistry and Molecular Biology, 44(5):429-432, 2016. © 2016 The International Union of Biochemistry and Molecular Biology.
Matsuo, Toshihiko; Gochi, Akira; Hirakawa, Tsuyoshi; Ito, Tadashi; Kohno, Yoshihisa
2010-10-01
General electronic medical records systems remain insufficient for ophthalmology outpatient clinics from the viewpoint of dealing with many ophthalmic examinations and images in a large number of patients. Filing systems for documents and images by Yahgee Document View (Yahgee, Inc.) were introduced on the platform of general electronic medical records system (Fujitsu, Inc.). Outpatients flow management system and electronic medical records system for ophthalmology were constructed. All images from ophthalmic appliances were transported to Yahgee Image by the MaxFile gateway system (P4 Medic, Inc.). The flow of outpatients going through examinations such as visual acuity testing were monitored by the list "Ophthalmology Outpatients List" by Yahgee Workflow in addition to the list "Patients Reception List" by Fujitsu. Patients' identification number was scanned with bar code readers attached to ophthalmic appliances. Dual monitors were placed in doctors' rooms to show Fujitsu Medical Records on the left-hand monitor and ophthalmic charts of Yahgee Document on the right-hand monitor. The data of manually-inputted visual acuity, automatically-exported autorefractometry and non-contact tonometry on a new template, MaxFile ED, were again automatically transported to designated boxes on ophthalmic charts of Yahgee Document. Images such as fundus photographs, fluorescein angiograms, optical coherence tomographic and ultrasound scans were viewed by Yahgee Image, and were copy-and-pasted to assigned boxes on the ophthalmic charts. Ordering such as appointments, drug prescription, fees and diagnoses input, central laboratory tests, surgical theater and ward room reservations were placed by functions of the Fujitsu electronic medical records system. The combination of the Fujitsu electronic medical records and Yahgee Document View systems enabled the University Hospital to examine the same number of outpatients as prior to the implementation of the computerized filing system.
Barbier, Paolo; Alimento, Marina; Berna, Giovanni; Cavoretto, Dario; Celeste, Fabrizio; Muratori, Manuela; Guazzi, Maurizio D
2004-01-01
Tele-echocardiography is not widely used because of lengthy transmission times when using standard Motion Pictures Expert Groups (MPEG)-2 lossy compression algorythms, unless expensive high bandwidth lines are used. We sought to validate the newer MPEG-4 algorythms to allow further reduction in echocardiographic motion video file size. Four cardiologists expert in echocardiography read blindly 165 randomized uncompressed and compressed 2D and color Doppler normal and pathologic motion images. One Digital Video and 3 MPEG-4 compression algorythms were tested, the latter at 3 decreasing compression quality levels (100%, 65% and 40%). Mean diagnostic and image quality scores were computed for each file and compared across the 3 compression levels using uncompressed files as controls. File dimensions decreased from a range of uncompressed 12-83 MB to MPEG-4 0.03-2.3 MB. All algorythms showed mean scores that were not significantly different from uncompressed source, except the MPEG-4 DivX algorythm at the highest selected compression (40%, p=.002). These data support the use of MPEG-4 compression to reduce echocardiographic motion image size for transmission purposes, allowing cost reduction through use of low bandwidth lines.
CEDIMS: cloud ethical DICOM image Mojette storage
NASA Astrophysics Data System (ADS)
Guédon, Jeanpierre; Evenou, Pierre; Tervé, Pierre; David, Sylvain; Béranger, Jérome
2012-02-01
Dicom images of patients will necessarily been stored in Clouds. However, ethical constraints must apply. In this paper, a method which provides the two following conditions is presented: 1) the medical information is not readable by the cloud owner since it is distributed along several clouds 2) the medical information can be retrieved from any sufficient subset of clouds In order to obtain this result in a real time processing, the Mojette transform is used. This paper reviews the interesting features of the Mojette transform in terms of information theory. Since only portions of the original Dicom files are stored into each cloud, their contents are not reachable. For instance, we use 4 different public clouds to save 4 different projections of each file, with the additional condition that any 3 over 4 projections are enough to reconstruct the original file. Thus, even if a cloud is unavailable when the user wants to load a Dicom file, the other 3 are giving enough information for real time reconstruction. The paper presents an implementation on 3 actual clouds. For ethical reasons, we use a Dicom image spreaded over 3 public clouds to show the obtained confidentiality and possible real time recovery.
Testing the Forensic Interestingness of Image Files Based on Size and Type
2017-09-01
there were still a lot of uninteresting files that were marked as interesting. Also, the results do not show a correlation between the...interesting, but there were still a lot of uninteresting files that were marked as interesting. Also, the results do not show a correlation between...7 IV. DESCRIPTION OF METHODOLOGY ...........................................................11 A. TEST SETUP
Morgan, Karen L. M.
2015-10-02
In addition to the photographs, a Google Earth Keyhole Markup Language (KML) file is provided and can be used to view the images by clicking on the marker and then clicking on either the thumbnail or the link above the thumbnail. The KML files were created using the photographic navigation files.
Curley, Louise E; Kennedy, Julia; Hinton, Jordan; Mirjalili, Ali; Svirskis, Darren
2017-01-01
Despite pharmaceutical sciences being a core component of pharmacy curricula, few published studies have focussed on innovative methodologies to teach the content. This commentary identifies imaging techniques which can visualise oral dosage forms in-vivo and observe formulation disintegration in order to achieve a better understanding of in-vivo performance. Images formed through these techniques can provide students with a deeper appreciation of the fate of oral formulations in the body compared to standard disintegration and dissolution testing, which is conducted in-vitro. Such images which represent the in-vivo setting can be used in teaching to give context to both theory and experimental work, thereby increasing student understanding and enabling teaching of pharmaceutical sciences supporting students to correlate in-vitro and in-vivo processes.
Electronic hand-drafting and picture management system.
Yang, Tsung-Han; Ku, Cheng-Yuan; Yen, David C; Hsieh, Wen-Huai
2012-08-01
The Department of Health of Executive Yuan in Taiwan (R.O.C.) is implementing a five-stage project entitled Electronic Medical Record (EMR) converting all health records from written to electronic form. Traditionally, physicians record patients' symptoms, related examinations, and suggested treatments on paper medical records. Currently when implementing the EMR, all text files and image files in the Hospital Information System (HIS) and Picture Archiving and Communication Systems (PACS) are kept separate. The current medical system environment is unable to combine text files, hand-drafted files, and photographs in the same system, so it is difficult to support physicians with the recording of medical data. Furthermore, in surgical and other related departments, physicians need immediate access to medical records in order to understand the details of a patient's condition. In order to address these problems, the Department of Health has implemented an EMR project, with the primary goal of building an electronic hand-drafting and picture management system (HDP system) that can be used by medical personnel to record medical information in a convenient way. This system can simultaneously edit text files, hand-drafted files, and image files and then integrate these data into Portable Document Format (PDF) files. In addition, the output is designed to fit a variety of formats in order to meet various laws and regulations. By combining the HDP system with HIS and PACS, the applicability can be enhanced to fit various scenarios and can assist the medical industry in moving into the final phase of EMR.
Computer Page: Computer Studies for All--A Wider Approach
ERIC Educational Resources Information Center
Edens, A. J.
1975-01-01
An approach to teaching children aged 12 through 14 a substantial course about computers is described. Topics covered include simple algorithms, information and communication, man-machine communication, the concept of a system, the definition of a system, and the use of files. (SD)
Division File of Extension Research Materials; Additions During 1968.
ERIC Educational Resources Information Center
Byrn, Darcie, Comp.
In this annotated bibliography of acquisitions during 1968 appear 265 Extension studies on administrative organization and management; training and staff development; mobilizing participation in Extension work; local leadership; program content and planning procedures; general effectiveness and progress in Extension; teaching methods, techniques,…
NASA Astrophysics Data System (ADS)
Walker, Justin A.
The introduction of complex treatment modalities such as IMRT and VMAT has led to the development of many devices for plan verification. One such innovation in this field is the repurposing of the portal imager to not only be used for tumor localization but for recording dose distributions as well. Several advantages make portal imagers attractive options for this purpose. Very high spatial resolution allows for better verification of small field plans than may be possible with commercially available devices. Because the portal imager is attached to the gantry set up is simpler than any other method available, requiring no additional accessories, and often can be accomplished from outside the treatment room. Dose images capture by the portal imager are in digital format make permanent records that can be analyzed immediately. Portal imaging suffers from a few limitations however that must be overcome. Images captured contain dose information and a calibration must be maintained for image to dose conversion. Dose images can only be taken perpendicular to the treatment beam allowing only for planar dose comparison. Planar dose files are themself difficult to obtain for VMAT treatments and an in-house script had to be developed to create such a file before analysis could be performed. Using the methods described in this study, excellent agreement between planar dose files generated and dose images taken were found. The average agreement for IMRT field analyzed being greater than 97% for non-normalized images at 3mm and 3%. Comparable agreement for VAMT plans was found as well with the average agreement being greater than 98%.
Martin, G. T.; Yoon, S. S.; Mott, K. E.
1991-01-01
Schistosomiasis, a group of parasitic diseases caused by Schistosoma parasites, is associated with water resources development and affects more than 200 million people in 76 countries. Depending on the species of parasite involved, disease of the liver, spleen, gastrointestinal or urinary tract, or kidneys may result. A computer-assisted teaching package has been developed by WHO for use in the training of public health workers involved in schistosomiasis control. The package consists of the software, ZOOM, and a schistosomiasis information file, Dr Schisto, and uses hypermedia technology to link pictures and text. ZOOM runs on the IBM-PC and IBM-compatible computers, is user-friendly, requires a minimal hardware configuration, and can interact with the user in English, French, Spanish or Portuguese. The information files for ZOOM can be created or modified by the instructor using a word processor, and thus can be designed to suit the need of students. No programming knowledge is required to create the stacks. PMID:1786618
NASA Astrophysics Data System (ADS)
Komo, Darmadi; Garra, Brian S.; Freedman, Matthew T.; Mun, Seong K.
1997-05-01
The Home Teleradiology Server system has been developed and installed at the Department of Radiology, Georgetown University Medical Center. The main purpose of the system is to provide a service for on-call physicians to view patients' medical images at home during off-hours. This service will reduce the overhead time required by on-call physicians to travel to the hospital, thereby increasing the efficiency of patient care and improving the total quality of the health care. Typically when a new case is conducted, the medical images generated from CT, US, and/or MRI modalities are transferred to a central server at the hospital via DICOM messages over an existing hospital network. The server has a DICOM network agent that listens to DICOM messages sent by CT, US, and MRI modalities and stores them into separate DICOM files for sending purposes. The server also has a general purpose, flexible scheduling software that can be configured to send image files to specific user(s) at certain times on any day(s) of the week. The server will then distribute the medical images to on- call physicians' homes via a high-speed modem. All file transmissions occur in the background without human interaction after the scheduling software is pre-configured accordingly. At the receiving end, the physicians' computers consist of high-end workstations that have high-speed modems to receive the medical images sent by the central server from the hospital, and DICOM compatible viewer software to view the transmitted medical images in DICOM format. A technician from the hospital, and DICOM compatible viewer software to view the transmitted medical images in DICOM format. A technician from the hospital will notify the physician(s) after all the image files have been completely sent. The physician(s) will then examine the medical images and decide if it is necessary to travel to the hospital for further examination on the patients. Overall, the Home Teleradiology system provides the on-call physicians with a cost-effective and convenient environment for viewing patients' medical images at home.
Delisser, Peter J; Carwardine, Darren
2017-11-29
Diagnostic imaging technology is becoming more advanced and widely available to veterinary patients with the growing popularity of veterinary-specific computed tomography (CT) and magnetic resonance imaging (MRI). Veterinary students must, therefore, be familiar with these technologies and understand the importance of sound anatomic knowledge for interpretation of the resultant images. Anatomy teaching relies heavily on visual perception of structures and their function. In addition, visual spatial ability (VSA) positively correlates with anatomy test scores. We sought to assess the impact of including more diagnostic imaging, particularly CT/MRI, in the teaching of veterinary anatomy on the students' perceived level of usefulness and ease of understanding content. Finally, we investigated survey answers' relationship to the students' inherent baseline VSA, measured by a standard Mental Rotations Test. Students viewed diagnostic imaging as a useful inclusion that provided clear links to clinical relevance, thus improving the students' perceived benefits in its use. Use of CT and MRI images was not viewed as more beneficial, more relevant, or more useful than the use of radiographs. Furthermore, students felt that the usefulness of CT/MRI inclusion was mitigated by the lack of prior formal instruction on the basics of CT/MRI image generation and interpretation. To be of significantly greater use, addition of learning resources labeling relevant anatomy in tomographical images would improve utility of this novel teaching resource. The present study failed to find any correlation between student perceptions of diagnostic imaging in anatomy teaching and their VSA.
Teaching Radiology Physics Interactively with Scientific Notebook Software.
Richardson, Michael L; Amini, Behrang
2018-06-01
The goal of this study is to demonstrate how the teaching of radiology physics can be enhanced with the use of interactive scientific notebook software. We used the scientific notebook software known as Project Jupyter, which is free, open-source, and available for the Macintosh, Windows, and Linux operating systems. We have created a scientific notebook that demonstrates multiple interactive teaching modules we have written for our residents using the Jupyter notebook system. Scientific notebook software allows educators to create teaching modules in a form that combines text, graphics, images, data, interactive calculations, and image analysis within a single document. These notebooks can be used to build interactive teaching modules, which can help explain complex topics in imaging physics to residents. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
TU-CD-304-11: Veritas 2.0: A Cloud-Based Tool to Facilitate Research and Innovation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mishra, P; Patankar, A; Etmektzoglou, A
Purpose: We introduce Veritas 2.0, a cloud-based, non-clinical research portal, to facilitate translation of radiotherapy research ideas to new delivery techniques. The ecosystem of research tools includes web apps for a research beam builder for TrueBeam Developer Mode, an image reader for compressed and uncompressed XIM files, and a trajectory log file based QA/beam delivery analyzer. Methods: The research beam builder can generate TrueBeam readable XML file either from scratch or from pre-existing DICOM-RT plans. DICOM-RT plan is first converted to XML format and then researcher can interactively modify or add control points to them. Delivered beam can be verifiedmore » via reading generated images and analyzing trajectory log files. Image reader can read both uncompressed and HND-compressed XIM images. The trajectory log analyzer lets researchers plot expected vs. actual values and deviations among 30 mechanical axes. The analyzer gives an animated view of MLC patterns for the beam delivery. Veritas 2.0 is freely available and its advantages versus standalone software are i) No software installation or maintenance needed, ii) easy accessibility across all devices iii) seamless upgrades and iv) OS independence. Veritas is written using open-source tools like twitter bootstrap, jQuery, flask, and Python-based modules. Results: In the first experiment, an anonymized 7-beam DICOM-RT IMRT plan was converted to XML beam containing 1400 control points. kV and MV imaging points were inserted into this XML beam. In another experiment, a binary log file was analyzed to compare actual vs expected values and deviations among axes. Conclusions: Veritas 2.0 is a public cloud-based web app that hosts a pool of research tools for facilitating research from conceptualization to verification. It is aimed at providing a platform for facilitating research and collaboration. I am full time employee at Varian Medical systems, Palo Alto.« less
OpenMSI: A High-Performance Web-Based Platform for Mass Spectrometry Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rubel, Oliver; Greiner, Annette; Cholia, Shreyas
Mass spectrometry imaging (MSI) enables researchers to directly probe endogenous molecules directly within the architecture of the biological matrix. Unfortunately, efficient access, management, and analysis of the data generated by MSI approaches remain major challenges to this rapidly developing field. Despite the availability of numerous dedicated file formats and software packages, it is a widely held viewpoint that the biggest challenge is simply opening, sharing, and analyzing a file without loss of information. Here we present OpenMSI, a software framework and platform that addresses these challenges via an advanced, high-performance, extensible file format and Web API for remote data accessmore » (http://openmsi.nersc.gov). The OpenMSI file format supports storage of raw MSI data, metadata, and derived analyses in a single, self-describing format based on HDF5 and is supported by a large range of analysis software (e.g., Matlab and R) and programming languages (e.g., C++, Fortran, and Python). Careful optimization of the storage layout of MSI data sets using chunking, compression, and data replication accelerates common, selective data access operations while minimizing data storage requirements and are critical enablers of rapid data I/O. The OpenMSI file format has shown to provide >2000-fold improvement for image access operations, enabling spectrum and image retrieval in less than 0.3 s across the Internet even for 50 GB MSI data sets. To make remote high-performance compute resources accessible for analysis and to facilitate data sharing and collaboration, we describe an easy-to-use yet powerful Web API, enabling fast and convenient access to MSI data, metadata, and derived analysis results stored remotely to facilitate high-performance data analysis and enable implementation of Web based data sharing, visualization, and analysis.« less
Construction of image database for newspapaer articles using CTS
NASA Astrophysics Data System (ADS)
Kamio, Tatsuo
Nihon Keizai Shimbun, Inc. developed a system of making articles' image database automatically by use of CTS (Computer Typesetting System). Besides the articles and the headlines inputted in CTS, it reproduces the image of elements of such as photography and graphs by article in accordance with information of position on the paper. So to speak, computer itself clips the articles out of the newspaper. Image database is accumulated in magnetic file and optical file and is output to the facsimile of users. With diffusion of CTS, newspaper companies which start to have structure of articles database are increased rapidly, the said system is the first attempt to make database automatically. This paper describes the device of CTS which supports this system and outline.
Infrared Imaging for Inquiry-Based Learning
ERIC Educational Resources Information Center
Xie, Charles; Hazzard, Edmund
2011-01-01
Based on detecting long-wavelength infrared (IR) radiation emitted by the subject, IR imaging shows temperature distribution instantaneously and heat flow dynamically. As a picture is worth a thousand words, an IR camera has great potential in teaching heat transfer, which is otherwise invisible. The idea of using IR imaging in teaching was first…
Students' Ideas about Prismatic Images: Teaching Experiments for an Image-Based Approach
ERIC Educational Resources Information Center
Grusche, Sascha
2017-01-01
Prismatic refraction is a classic topic in science education. To investigate how undergraduate students think about prismatic dispersion, and to see how they change their thinking when observing dispersed images, five teaching experiments were done and analysed according to the Model of Educational Reconstruction. For projection through a prism,…
Malpractice claims related to musculoskeletal imaging. Incidence and anatomical location of lesions.
Fileni, Adriano; Fileni, Gaia; Mirk, Paoletta; Magnavita, Giulia; Nicoli, Marzia; Magnavita, Nicola
2013-12-01
Failure to detect lesions of the musculoskeletal system is a frequent cause of malpractice claims against radiologists. We examined all the malpractice claims related to alleged errors in musculoskeletal imaging filed against Italian radiologists over a period of 14 years (1993-2006). During the period considered, a total of 416 claims for alleged diagnostic errors relating to the musculoskeletal system were filed against radiologists; of these, 389 (93.5%) concerned failure to report fractures, and 15 (3.6%) failure to diagnose a tumour. Incorrect interpretation of bone pathology is among the most common causes of litigation against radiologists; alone, it accounts for 36.4% of all malpractice claims filed during the observation period. Awareness of this risk should encourage extreme caution and diligence.
Implementation of a Landscape Lighting System to Display Images
NASA Astrophysics Data System (ADS)
Sun, Gi-Ju; Cho, Sung-Jae; Kim, Chang-Beom; Moon, Cheol-Hong
The system implemented in this study consists of a PC, MASTER, SLAVEs and MODULEs. The PC sets the various landscape lighting displays, and the image files can be sent to the MASTER through a virtual serial port connected to the USB (Universal Serial Bus). The MASTER sends a sync signal to the SLAVE. The SLAVE uses the signal received from the MASTER and the landscape lighting display pattern. The video file is saved in the NAND Flash memory and the R, G, B signals are separated using the self-made display signal and sent to the MODULE so that it can display the image.
Bankey, Viki; Grauch, V.J.S.; ,
2004-01-01
This report contains digital data, image files, and text files describing data formats and survey procedures for aeromagnetic data collected during a helicopter geophysical survey in northern New Mexico during October 2003. The survey covers the Town of Taos, Taos Pueblo, and surrounding communities in Taos County. Several derivative products from these data are also presented, including reduced-to-pole, horizontal gradient magnitude, and downward continued grids and images.
Bankey, Viki; Grauch, V.J.S.; ,
2004-01-01
This CD-ROM contains digital data, image files, and text files describing data formats and survey procedures for aeromagnetic data collected during a helicopter geophysical survey in southern Colorado during October 2003. The survey covers the town of Blanca and surrounding communities in Alamosa and Costilla Counties. Several derivative products from these data are also presented, including reduced-to-pole, horizontal gradient magnitude, and downward continued grids and images.
SU-E-E-06: Teaching About the Gamma Camera and Ultrasound Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lowe, M; Spiro, A; Vogel, R
Purpose: Instructional modules on applications of physics in medicine are being developed. The target audience consists of students who have had an introductory undergraduate physics course. This presentation will concentrate on an active learning approach to teach the principles of the gamma camera. There will also be a description of an apparatus to teach ultrasound imaging. Methods: Since a real gamma camera is not feasible in the undergraduate classroom, we have developed two types of optical apparatus that teach the main principles. To understand the collimator, LEDS mimic gamma emitters in the body, and the photons pass through an arraymore » of tubes. The distance, spacing, diameter, and length of the tubes can be varied to understand the effect upon the resolution of the image. To determine the positions of the gamma emitters, a second apparatus uses a movable green laser, fluorescent plastic in lieu of the scintillation crystal, acrylic rods that mimic the PMTs, and a photodetector to measure the intensity. The position of the laser is calculated with a centroid algorithm.To teach the principles of ultrasound imaging, we are using the sound head and pulser box of an educational product, variable gain amplifier, rotation table, digital oscilloscope, Matlab software, and phantoms. Results: Gamma camera curriculum materials have been implemented in the classroom at Loyola in 2014 and 2015. Written work shows good knowledge retention and a more complete understanding of the material. Preliminary ultrasound imaging materials were run in 2015. Conclusion: Active learning methods add another dimension to descriptions in textbooks and are effective in keeping the students engaged during class time. The teaching apparatus for the gamma camera and ultrasound imaging can be expanded to include more cases, and could potentially improve students’ understanding of artifacts and distortions in the images.« less
Educational Knowledge Generation from Administrative Data
ERIC Educational Resources Information Center
Arevalillo-Herraez, Miguel; Moreno-Clari, Paloma; Cerveron-Lleo, Vicente
2011-01-01
Most universities use Information Systems (IS) to perform their daily administrative activities (student enrollment, data files, accountancy, etc.), and an integrated Learning Management System (LMS) to support teaching and learning. However, although a lot of effort has been put into deploying these computerized systems, the data that they…
Teaching Information Retrieval: Lessons from Cornell.
ERIC Educational Resources Information Center
Stewart, Linda Guyotte; Markiewicz, James
1986-01-01
This article describes two separate workshops offered to college faculty during the spring 1984 semester: one in online bibliographic searching, one in using computers to manage personal files of bibliographic references (examination of existing systems, types of software available). A telephone survey evaluation conducted 3 months after sessions…
New Tools to Prepare ACE Cross-section Files for MCNP Analytic Test Problems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Forrest B.
Monte Carlo calculations using one-group cross sections, multigroup cross sections, or simple continuous energy cross sections are often used to: (1) verify production codes against known analytical solutions, (2) verify new methods and algorithms that do not involve detailed collision physics, (3) compare Monte Carlo calculation methods with deterministic methods, and (4) teach fundamentals to students. In this work we describe 2 new tools for preparing the ACE cross-section files to be used by MCNP ® for these analytic test problems, simple_ace.pl and simple_ace_mg.pl.
77 FR 11483 - Request for Extension of a Currently Approved Information Collection
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-27
... that is a scanned Adobe PDF file, it must be scanned as text and not as an image, thus allowing FCIC to... February 17, 2012. William J. Murphy, Manager, Federal Crop Insurance Corporation. [FR Doc. 2012-4465 Filed...
Three dimensional ultrasound and hdlive technology as possible tools in teaching embryology.
Popovici, Razvan; Pristavu, Anda; Sava, Anca
2017-10-01
Embryology is an important subject in order to gain an understanding of medicine and surgery; however, sometimes students find the subject difficult to grasp and apply to clinical practice. Modern imaging techniques can be useful aids in teaching and understanding embryology. Imaging techniques have very rapidly evolved over the last few years, advancing from two- to three-dimensional (3D) ultrasound. HDlive is an innovative ultrasound technique that generates near-realistic images of the human fetus. In order to evince the capabilities of 3D ultrasound and HDlive technology in teaching embryology, we evaluated using this technique the normal evolution of the embryo and fetus from the fifth to eleventh week of amenorrhea. Our conclusion is that by yielding clear and impressive images, 3D ultrasound and HDlive could be useful tools in teaching embryology to medical students. Clin. Anat. 30:953-957, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Glide path preparation in S-shaped canals with rotary pathfinding nickel-titanium instruments.
Ajuz, Natasha C C; Armada, Luciana; Gonçalves, Lucio S; Debelian, Gilberto; Siqueira, José F
2013-04-01
This study compared the incidence of deviation along S-shaped (double-curved) canals after glide path preparation with 2 nickel-titanium (NiTi) rotary pathfinding instruments and hand K-files. S-shaped canals from 60 training blocks were filled with ink, and preinstrumentation images were obtained by using a stereomicroscope. Glide path preparation was performed by an endodontist who used hand stainless steel K-files (up to size 20), rotary NiTi PathFile instruments (up to size 19), or rotary NiTi Scout RaCe instruments (up to size 20). Postinstrumentation images were taken by using exactly the same conditions as for the preinstrumentation images, and both pictures were superimposed. Differences along the S-shaped canal for the mesial and distal aspects were measured to evaluate the occurrence of deviation. Intragroup analysis showed that all instruments promoted some deviation in virtually all levels. Overall, regardless of the group, deviations were observed in the mesial wall at the canal terminus and at levels 4, 5, 6 and 7 mm and in the distal wall at levels 1, 2, and 3 mm. These levels corresponded to the inner walls of each curvature. Both rotary NiTi instruments performed significantly better than hand K-files at all levels (P < .05), except for PathFiles at the 0-mm level. ScoutRaCe instruments showed significantly better results than PathFiles at levels 0, 2, 3, 5, and 6 mm (P < .05). Findings suggest that rotary NiTi instruments are suitable for adequate glide path preparation because they promoted less deviation from the original canal anatomy when compared with hand-operated instruments. Of the 2 rotary pathfinding instruments, Scout RaCe showed an overall significantly better performance. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
2012-05-01
WE RECOMMEND Scientific American—The Amateur Scientist 3.0 Article collection spans the decades DynaKar DynaKar drives dynamics experiments The Fundamentals of Imaging Author covers whole imaging spectrum Teaching Secondary Physics Effective teaching is all in the approach Novel Materials and Smart Applications/Novel materials sample pack Resources kit samples smart materials WORTH A LOOK Cryptic disk Metal disk spins life into discussions about energy, surfaces and kinetics HANDLE WITH CARE The New Resourceful Physics Teacher Book brings creativity to physics WEB WATCH Apps for tablets and smartphones can aid physics teaching
Interactive publications: creation and usage
NASA Astrophysics Data System (ADS)
Thoma, George R.; Ford, Glenn; Chung, Michael; Vasudevan, Kirankumar; Antani, Sameer
2006-02-01
As envisioned here, an "interactive publication" has similarities to multimedia documents that have been in existence for a decade or more, but possesses specific differentiating characteristics. In common usage, the latter refers to online entities that, in addition to text, consist of files of images and video clips residing separately in databases, rarely providing immediate context to the document text. While an interactive publication has many media objects as does the "traditional" multimedia document, it is a self-contained document, either as a single file with media files embedded within it, or as a "folder" containing tightly linked media files. The main characteristic that differentiates an interactive publication from a traditional multimedia document is that the reader would be able to reuse the media content for analysis and presentation, and to check the underlying data and possibly derive alternative conclusions leading, for example, to more in-depth peer reviews. We have created prototype publications containing paginated text and several media types encountered in the biomedical literature: 3D animations of anatomic structures; graphs, charts and tabular data; cell development images (video sequences); and clinical images such as CT, MRI and ultrasound in the DICOM format. This paper presents developments to date including: a tool to convert static tables or graphs into interactive entities, authoring procedures followed to create prototypes, and advantages and drawbacks of each of these platforms. It also outlines future work including meeting the challenge of network distribution for these large files.
ERIC Educational Resources Information Center
Zhang, Xiaofen; Clements, M. A.; Ellerton, Nerida F.
2015-01-01
This study investigated how fifth-grade children's concept images of the unit fractions represented by the symbols 1/2, 1/3/ and 1/4 changed as a result of their participation in an instructional intervention based on multiple embodiments of fraction concepts. The participants' concept images were examined through pre- and post-teaching written…
NASA Astrophysics Data System (ADS)
Gatlin, Todd Adam
Graduate teaching assistants (GTAs) play a prominent role in chemistry laboratory instruction at research based universities. They teach almost all undergraduate chemistry laboratory courses. However, their role in laboratory instruction has often been overlooked in educational research. Interest in chemistry GTAs has been placed on training and their perceived expectations, but less attention has been paid to their experiences or their potential benefits from teaching. This work was designed to investigate GTAs' experiences in and benefits from laboratory instructional environments. This dissertation includes three related studies on GTAs' experiences teaching in general chemistry laboratories. Qualitative methods were used for each study. First, phenomenological analysis was used to explore GTAs' experiences in an expository laboratory program. Post-teaching interviews were the primary data source. GTAs experiences were described in three dimensions: doing, knowing, and transferring. Gains available to GTAs revolved around general teaching skills. However, no gains specifically related to scientific development were found in this laboratory format. Case-study methods were used to explore and illustrate ways GTAs develop a GTA self-image---the way they see themselves as instructors. Two general chemistry laboratory programs that represent two very different instructional frameworks were chosen for the context of this study. The first program used a cooperative project-based approach. The second program used weekly, verification-type activities. End of the semester interviews were collected and served as the primary data source. A follow-up case study of a new cohort of GTAs in the cooperative problem-based laboratory was undertaken to investigate changes in GTAs' self-images over the course of one semester. Pre-semester and post-semester interviews served as the primary data source. Findings suggest that GTAs' construction of their self-image is shaped through the interaction of 1) prior experiences, 2) training, 3) beliefs about the nature of knowledge, 4) beliefs about the nature of laboratory work, and 5) involvement in the laboratory setting. Further GTAs' self-images are malleable and susceptible to change through their laboratory teaching experiences. Overall, this dissertation contributes to chemistry education by providing a model useful for exploring GTAs' development of a self-image in laboratory teaching. This work may assist laboratory instructors and coordinators in reconsidering, when applicable, GTA training and support. This work also holds considerable implications for how teaching experiences are conceptualized as part of the chemistry graduate education experience. Findings suggest that appropriate teaching experiences may contribute towards better preparing graduate students for their journey in becoming scientists.
Harris, T; Leaven, T; Heidger, P; Kreiter, C; Duncan, J; Dick, F
2001-02-01
Emerging technology now exists to digitize a gigabyte of information from a glass slide, save it in a highly compressed file format, and deliver it over the web. By accessing these images with a standard web browser and viewer plug-in, a computer can emulate a real microscope and glass slide. Using this new technology, the immediate aims of our project were to digitize the glass slides from urinary tract, male genital, and endocrine units and implement them in the Spring 2000 Histology course at the University of Iowa, and to carry out a formative evaluation of the virtual slides of these three units in a side-by-side comparison with the regular microscope laboratory. The methods and results of this paper will describe the technology employed to create the virtual slides, and the formative evaluation carried out in the course. Anat Rec (New Anat) 265:10-14, 2001. Copyright 2001 Wiley-Liss, Inc.
MSL: Facilitating automatic and physical analysis of published scientific literature in PDF format.
Ahmed, Zeeshan; Dandekar, Thomas
2015-01-01
Published scientific literature contains millions of figures, including information about the results obtained from different scientific experiments e.g. PCR-ELISA data, microarray analysis, gel electrophoresis, mass spectrometry data, DNA/RNA sequencing, diagnostic imaging (CT/MRI and ultrasound scans), and medicinal imaging like electroencephalography (EEG), magnetoencephalography (MEG), echocardiography (ECG), positron-emission tomography (PET) images. The importance of biomedical figures has been widely recognized in scientific and medicine communities, as they play a vital role in providing major original data, experimental and computational results in concise form. One major challenge for implementing a system for scientific literature analysis is extracting and analyzing text and figures from published PDF files by physical and logical document analysis. Here we present a product line architecture based bioinformatics tool 'Mining Scientific Literature (MSL)', which supports the extraction of text and images by interpreting all kinds of published PDF files using advanced data mining and image processing techniques. It provides modules for the marginalization of extracted text based on different coordinates and keywords, visualization of extracted figures and extraction of embedded text from all kinds of biological and biomedical figures using applied Optimal Character Recognition (OCR). Moreover, for further analysis and usage, it generates the system's output in different formats including text, PDF, XML and images files. Hence, MSL is an easy to install and use analysis tool to interpret published scientific literature in PDF format.
Joseph, Mercy; Malhotra, Amit; Rao, Murali; Sharma, Abhimanyu; Talwar, Sangeeta
2016-01-01
Background Complete removal of old filling material during root canal retreatment is fundamental for predictable cleaning and shaping of canal anatomy. Most of the retreatment methods tested in earlier studies have shown inability to achieve complete removal of root canal filling. Therefore the aim of this investigation was to assess the efficacy of three different rotary nickel titanium retreatment systems and Hedstrom files in removing filling material from root canals. Material and Methods Sixty extracted mandibular premolars were decoronated to leave 15 mm root. Specimen were hand instrumented and obturated using gutta percha and AH plus root canal sealer. After storage period of two weeks, roots were retreated with three (Protaper retreatment files, Mtwo retreatment files, NRT GPR) rotary retreatment instrument systems and Hedstroem files. Subsequently, samples were sectioned longitudinally and examined under stereomicroscope. Digital images were recorded and evaluated using Digital Image Analysing Software. The retreatment time was recorded for each tooth using a stopwatch. The area of canal and the residual filling material was recorded in mm2 and the percentage of remaining filling material on canal walls was calculated. Data was analysed using ANOVA test. Results Significantly less amount of residual filling material was present in protaper and Mtwo instrumented teeth (p < 0.05) compared to NRT GPR and Hedstrom files group. Protaper instruments also required lesser time during removal of filling material followed by Mtwo instruments, NRT GPR files and Hedstrom files. Conclusions None of the instruments were able to remove the filling material completely from root canal. Protaper universal retreatment system and Mtwo retreatment files were more efficient and faster compared to NRT GPR fles and Hedstrom files. Key words:Gutta-percha removal, nickel titanium, root canal retreatment, rotary instruments. PMID:27703601
Teaching medical students cancer risk reduction nutrition counseling using a multimedia program.
Kolasa, K M; Jobe, A C; Miller, M G; Clay, M C
1999-03-01
There are many barriers to medical students receiving education about the linkage between nutrition and cancer, including the lack of role models and teachers and insufficient curricular time. We tested the use of a multimedia program as a possible solution to teaching diet-risk assessment and counseling skills. Images of Cancer Prevention, The Nutrition Link is a CD-ROM multimedia program that was developed and evaluated by 147 medical students. Pre-use and post-use surveys, computer log files, and recorded response sessions were used to determine the learner's 1) ease in using the program, 2) attitudes about the treatment of the content, 3) knowledge gain, and 4) attitudes about the role of physicians in nutrition assessment and counseling for cancer risk reduction. Students improved their knowledge of dietary guidelines for cancer risk reduction and made positive changes in their attitudes toward the role of physicians in dietary counseling. However, most students reported that they would not use the program unless it was required that they do so. The multimedia program was successful; it affected students' knowledge and attitudes concerning nutrition as a modifiable risk factor for some cancers. In addition, the design and delivery of the multimedia product was positively reviewed by the students for ease of access, message design, individualized instruction, and flexibility. Despite these favorable ratings, it was not clear that students would use the program unless required to do so.
NASA Astrophysics Data System (ADS)
Cao, Binfang; Li, Xiaoqin; Liu, Changqing; Li, Jianqi
2017-08-01
With the further applied transformation of local colleges, teachers are urgently needed to make corresponding changes in the teaching content and methods from different courses. The article discusses practice teaching reform of the Photoelectric Image Processing course in the Optoelectronic Information Science and Engineering major. The Digital Signal Processing (DSP) platform is introduced to the experimental teaching. It will mobilize and inspire students and also enhance their learning motivation and innovation through specific examples. The course via teaching practice process has become the most popular course among students, which will further drive students' enthusiasm and confidence to participate in all kinds of electronic competitions.
NASA Astrophysics Data System (ADS)
Kielkopf, John F.; Carter, B.; Brown, C.; Hart, R.; Hay, J.; Waite, I.
2007-12-01
The Digital Science Partnership, a collaboration of the University of Louisville and the University of Southern Queensland, operates a pair of 0.5-meter telescopes for teaching, research, and informal education. The instruments were installed at sites near Toowoomba, Australia, and Louisville, Kentucky in 2006. The Planewave Instruments optical systems employ a unique Dall-Kirkham design incorporating a two-element corrector that demagnifies the image, flattens the focal plane, and reduces coma. These instruments have a moderately fast f/6.8 focal ratio and maintain image quality with little vignetting over a field 42 mm in diameter (0.7 degree). With a 9-micron pixel CCD such as the KAF-6303E, the image scale of 0.55 seconds of arc per pixel typically yields seeing-limited image quality at our sites. The telescopes and their enclosure are operated in a live remote observing mode through Linux-based software, including a dome-control system that uses RFID tags for absolute rotation encoding. After several months of testing and development we have examples of images and photometry from both sites that illustrate the performance of the system. We will discuss image quality, as well as practical matters such as pointing accuracy and field acquisition, auto-guiding, communication latency in large file transfer, and our experience with remote observing assisted by teleconferencing. Time-delay-integration (TDI) imaging, in which the telescope is stationary while the CCD is clocked to track in right ascension, is under study. The technique offers wide fields of view with very high signal-to-noise ratio, and can be implemented in robotically operated instruments used in monitoring, rapid-response, and educational programs. Results for conventional and TDI imaging from the dark site in Australia compared to the brighter suburban site in Kentucky show the benefits of access to dark sites through international partnerships that remote operation technology offers.
Method for position emission mammography image reconstruction
Smith, Mark Frederick
2004-10-12
An image reconstruction method comprising accepting coincidence datat from either a data file or in real time from a pair of detector heads, culling event data that is outside a desired energy range, optionally saving the desired data for each detector position or for each pair of detector pixels on the two detector heads, and then reconstructing the image either by backprojection image reconstruction or by iterative image reconstruction. In the backprojection image reconstruction mode, rays are traced between centers of lines of response (LOR's), counts are then either allocated by nearest pixel interpolation or allocated by an overlap method and then corrected for geometric effects and attenuation and the data file updated. If the iterative image reconstruction option is selected, one implementation is to compute a grid Siddon retracing, and to perform maximum likelihood expectation maiximization (MLEM) computed by either: a) tracing parallel rays between subpixels on opposite detector heads; or b) tracing rays between randomized endpoint locations on opposite detector heads.
OMERO and Bio-Formats 5: flexible access to large bioimaging datasets at scale
NASA Astrophysics Data System (ADS)
Moore, Josh; Linkert, Melissa; Blackburn, Colin; Carroll, Mark; Ferguson, Richard K.; Flynn, Helen; Gillen, Kenneth; Leigh, Roger; Li, Simon; Lindner, Dominik; Moore, William J.; Patterson, Andrew J.; Pindelski, Blazej; Ramalingam, Balaji; Rozbicki, Emil; Tarkowska, Aleksandra; Walczysko, Petr; Allan, Chris; Burel, Jean-Marie; Swedlow, Jason
2015-03-01
The Open Microscopy Environment (OME) has built and released Bio-Formats, a Java-based proprietary file format conversion tool and OMERO, an enterprise data management platform under open source licenses. In this report, we describe new versions of Bio-Formats and OMERO that are specifically designed to support large, multi-gigabyte or terabyte scale datasets that are routinely collected across most domains of biological and biomedical research. Bio- Formats reads image data directly from native proprietary formats, bypassing the need for conversion into a standard format. It implements the concept of a file set, a container that defines the contents of multi-dimensional data comprised of many files. OMERO uses Bio-Formats to read files natively, and provides a flexible access mechanism that supports several different storage and access strategies. These new capabilities of OMERO and Bio-Formats make them especially useful for use in imaging applications like digital pathology, high content screening and light sheet microscopy that create routinely large datasets that must be managed and analyzed.
The Native American Experience. American Historical Images on File.
ERIC Educational Resources Information Center
Wardwell, Lelia, Ed.
This photo-documentation reference body presents more than 275 images chronicling the experiences of the American Indian from their prehistoric migrations to the present. The volume includes information and images illustrating the life ways of various tribes. The images are accompanied by historical information providing cultural context. The book…
Computer Courseware Evaluations. January 1988 to December 1988. Volume VIII.
ERIC Educational Resources Information Center
Riome, Carol-Anne, Comp.
The eighth in a series, this report reviews microcomputer software authorized by the Alberta (Canada) Department of Education from January 1988 through December 1988. This edition provides detailed evaluations of 40 authorized programs for teaching business education, computer literacy, databases, file management, French, information retrieval,…
A Study of Personal Information Management Strategies for Online Faculty
ERIC Educational Resources Information Center
Kearns, Lorna R.; Frey, Barbara A.; Tomer, Christinger; Alman, Susan
2014-01-01
The literature suggests that personal information management is a serious challenge for many computer users. Online faculty are especially challenged because of the large number of electronic files necessitated by teaching online. Those who have experience in this environment may offer valuable insights regarding information management challenges…
Union Sues over Basis of Appraisal
ERIC Educational Resources Information Center
Sawchuk, Stephen
2013-01-01
The National Education Association, on behalf of three affiliates of its Florida chapter and seven teachers, last week filed suit against the Florida education department. They contend that some teachers are being judged against students or subjects they don't teach, in violation of their constitutional rights. The groups seek a federal court…
77 FR 75606 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-21
..., filing of petitions and applications and agency #0;statements of organization and functions are examples... Scholarship recipients are required to study in the food, and agricultural, and related sciences, as defined by the National Agricultural Research, Extension, and Teaching Policy Act of 1977 (7 U.S.C. 3103(8...
ERIC Educational Resources Information Center
Unal, Hasan
2011-01-01
The purpose of this study was to investigate the preservice secondary mathematics teachers' development of pedagogical understanding in the teaching of modular arithmetic problems. Data sources included, written assignments, interview transcripts and filed notes. Using case study and action research approaches cases of three preservice teachers…
ERIC Educational Resources Information Center
McDonald, James; Dominguez, Lynn
2012-01-01
As children develop misconceptions about animals they believe are dangerous, they also adopt attitudes that are difficult to change. Changing these attitudes is challenging for teachers. One animal that is easy to find but difficult for children to understand is a spider. As with most wild animals, they are difficult to teach about because…
Library Dream Machines: Helping Students Master Super Online Catalogs.
ERIC Educational Resources Information Center
Webb, T. D.
1992-01-01
Describes how automation has transformed the library and how super-catalogs have affected the process of doing research. Explains how faculty and librarians can work together to help students to use the available databases effectively, by teaching them Boolean logic, standard record formats, filing rules, etc. (DMM)
Administrative Leadership and the Development of a Research University.
ERIC Educational Resources Information Center
Bjork, Lars G.
Administrative leadership as a factor associated with the development of the University of New Mexico from an undergraduate teaching institution toward a nationally-ranked graduate research university is discussed. An ethnographic approach was employed for the institutional study, using documents from the university files and informal interviews.…
Practical Materials for Teaching. Resource File: Edition I. Energy Management.
ERIC Educational Resources Information Center
Department of Energy, Washington, DC.
This directory lists energy education programs directed at increasing the energy conservation awareness of scientists, engineers, managers, and technicians working in fields where they are responsible for managing energy consumption. The resource is prepared to help with the process of identifying, selecting, and obtaining materials for promoting…
The Northern Ireland Resource File and Aspire
ERIC Educational Resources Information Center
Ryan, David; Montgomery, Brenda
2016-01-01
The paper begins by identifying issues as to how initial teacher training and in-service training for teachers inadequately prepares them for teaching the pupils with special educational needs (SEN). The paper then provides a brief legislative background to SEN in the Northern Ireland context, before describing two elements of educational reform…
Challenges for data storage in medical imaging research.
Langer, Steve G
2011-04-01
Researchers in medical imaging have multiple challenges for storing, indexing, maintaining viability, and sharing their data. Addressing all these concerns requires a constellation of tools, but not all of them need to be local to the site. In particular, the data storage challenges faced by researchers can begin to require professional information technology skills. With limited human resources and funds, the medical imaging researcher may be better served with an outsourcing strategy for some management aspects. This paper outlines an approach to manage the main objectives faced by medical imaging scientists whose work includes processing and data mining on non-standard file formats, and relating those files to the their DICOM standard descendents. The capacity of the approach scales as the researcher's need grows by leveraging the on-demand provisioning ability of cloud computing.
Parallel object-oriented data mining system
Kamath, Chandrika; Cantu-Paz, Erick
2004-01-06
A data mining system uncovers patterns, associations, anomalies and other statistically significant structures in data. Data files are read and displayed. Objects in the data files are identified. Relevant features for the objects are extracted. Patterns among the objects are recognized based upon the features. Data from the Faint Images of the Radio Sky at Twenty Centimeters (FIRST) sky survey was used to search for bent doubles. This test was conducted on data from the Very Large Array in New Mexico which seeks to locate a special type of quasar (radio-emitting stellar object) called bent doubles. The FIRST survey has generated more than 32,000 images of the sky to date. Each image is 7.1 megabytes, yielding more than 100 gigabytes of image data in the entire data set.
Steganalysis feature improvement using expectation maximization
NASA Astrophysics Data System (ADS)
Rodriguez, Benjamin M.; Peterson, Gilbert L.; Agaian, Sos S.
2007-04-01
Images and data files provide an excellent opportunity for concealing illegal or clandestine material. Currently, there are over 250 different tools which embed data into an image without causing noticeable changes to the image. From a forensics perspective, when a system is confiscated or an image of a system is generated the investigator needs a tool that can scan and accurately identify files suspected of containing malicious information. The identification process is termed the steganalysis problem which focuses on both blind identification, in which only normal images are available for training, and multi-class identification, in which both the clean and stego images at several embedding rates are available for training. In this paper an investigation of a clustering and classification technique (Expectation Maximization with mixture models) is used to determine if a digital image contains hidden information. The steganalysis problem is for both anomaly detection and multi-class detection. The various clusters represent clean images and stego images with between 1% and 10% embedding percentage. Based on the results it is concluded that the EM classification technique is highly suitable for both blind detection and the multi-class problem.
New directions in the CernVM file system
NASA Astrophysics Data System (ADS)
Blomer, Jakob; Buncic, Predrag; Ganis, Gerardo; Hardi, Nikola; Meusel, Rene; Popescu, Radu
2017-10-01
The CernVM File System today is commonly used to host and distribute application software stacks. In addition to this core task, recent developments expand the scope of the file system into two new areas. Firstly, CernVM-FS emerges as a good match for container engines to distribute the container image contents. Compared to native container image distribution (e.g. through the “Docker registry”), CernVM-FS massively reduces the network traffic for image distribution. This has been shown, for instance, by a prototype integration of CernVM-FS into Mesos developed by Mesosphere, Inc. We present a path for a smooth integration of CernVM-FS and Docker. Secondly, CernVM-FS recently raised new interest as an option for the distribution of experiment conditions data. Here, the focus is on improved versioning capabilities of CernVM-FS that allows to link the conditions data of a run period to the state of a CernVM-FS repository. Lastly, CernVM-FS has been extended to provide a name space for physics data for the LIGO and CMS collaborations. Searching through a data namespace is often done by a central, experiment specific database service. A name space on CernVM-FS can particularly benefit from an existing, scalable infrastructure and from the POSIX file system interface.
A new version of Visual tool for estimating the fractal dimension of images
NASA Astrophysics Data System (ADS)
Grossu, I. V.; Felea, D.; Besliu, C.; Jipa, Al.; Bordeianu, C. C.; Stan, E.; Esanu, T.
2010-04-01
This work presents a new version of a Visual Basic 6.0 application for estimating the fractal dimension of images (Grossu et al., 2009 [1]). The earlier version was limited to bi-dimensional sets of points, stored in bitmap files. The application was extended for working also with comma separated values files and three-dimensional images. New version program summaryProgram title: Fractal Analysis v02 Catalogue identifier: AEEG_v2_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEEG_v2_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 9999 No. of bytes in distributed program, including test data, etc.: 4 366 783 Distribution format: tar.gz Programming language: MS Visual Basic 6.0 Computer: PC Operating system: MS Windows 98 or later RAM: 30 M Classification: 14 Catalogue identifier of previous version: AEEG_v1_0 Journal reference of previous version: Comput. Phys. Comm. 180 (2009) 1999 Does the new version supersede the previous version?: Yes Nature of problem: Estimating the fractal dimension of 2D and 3D images. Solution method: Optimized implementation of the box-counting algorithm. Reasons for new version:The previous version was limited to bitmap image files. The new application was extended in order to work with objects stored in comma separated values (csv) files. The main advantages are: Easier integration with other applications (csv is a widely used, simple text file format); Less resources consumed and improved performance (only the information of interest, the "black points", are stored); Higher resolution (the points coordinates are loaded into Visual Basic double variables [2]); Possibility of storing three-dimensional objects (e.g. the 3D Sierpinski gasket). In this version the optimized box-counting algorithm [1] was extended to the three-dimensional case. Summary of revisions:The application interface was changed from SDI (single document interface) to MDI (multi-document interface). One form was added in order to provide a graphical user interface for the new functionalities (fractal analysis of 2D and 3D images stored in csv files). Additional comments: User friendly graphical interface; Easy deployment mechanism. Running time: In the first approximation, the algorithm is linear. References:[1] I.V. Grossu, C. Besliu, M.V. Rusu, Al. Jipa, C.C. Bordeianu, D. Felea, Comput. Phys. Comm. 180 (2009) 1999-2001.[2] F. Balena, Programming Microsoft Visual Basic 6.0, Microsoft Press, US, 1999.
NASA Technical Reports Server (NTRS)
Stanfill, D. F.
1994-01-01
Pixel Pusher is a Macintosh application used for viewing and performing minor enhancements on imagery. It will read image files in JPL's two primary image formats- VICAR and PDS - as well as the Macintosh PICT format. VICAR (NPO-18076) handles an array of image processing capabilities which may be used for a variety of applications including biomedical image processing, cartography, earth resources, and geological exploration. Pixel Pusher can also import VICAR format color lookup tables for viewing images in pseudocolor (256 colors). This program currently supports only eight bit images but will work on monitors with any number of colors. Arbitrarily large image files may be viewed in a normal Macintosh window. Color and contrast enhancement can be performed with a graphical "stretch" editor (as in contrast stretch). In addition, VICAR images may be saved as Macintosh PICT files for exporting into other Macintosh programs, and individual pixels can be queried to determine their locations and actual data values. Pixel Pusher is written in Symantec's Think C and was developed for use on a Macintosh SE30, LC, or II series computer running System Software 6.0.3 or later and 32 bit QuickDraw. Pixel Pusher will only run on a Macintosh which supports color (whether a color monitor is being used or not). The standard distribution medium for this program is a set of three 3.5 inch Macintosh format diskettes. The program price includes documentation. Pixel Pusher was developed in 1991 and is a copyrighted work with all copyright vested in NASA. Think C is a trademark of Symantec Corporation. Macintosh is a registered trademark of Apple Computer, Inc.
Image fusion in craniofacial virtual reality modeling based on CT and 3dMD photogrammetry.
Xin, Pengfei; Yu, Hongbo; Cheng, Huanchong; Shen, Shunyao; Shen, Steve G F
2013-09-01
The aim of this study was to demonstrate the feasibility of building a craniofacial virtual reality model by image fusion of 3-dimensional (3D) CT models and 3 dMD stereophotogrammetric facial surface. A CT scan and stereophotography were performed. The 3D CT models were reconstructed by Materialise Mimics software, and the stereophotogrammetric facial surface was reconstructed by 3 dMD patient software. All 3D CT models were exported as Stereo Lithography file format, and the 3 dMD model was exported as Virtual Reality Modeling Language file format. Image registration and fusion were performed in Mimics software. Genetic algorithm was used for precise image fusion alignment with minimum error. The 3D CT models and the 3 dMD stereophotogrammetric facial surface were finally merged into a single file and displayed using Deep Exploration software. Errors between the CT soft tissue model and 3 dMD facial surface were also analyzed. Virtual model based on CT-3 dMD image fusion clearly showed the photorealistic face and bone structures. Image registration errors in virtual face are mainly located in bilateral cheeks and eyeballs, and the errors are more than 1.5 mm. However, the image fusion of whole point cloud sets of CT and 3 dMD is acceptable with a minimum error that is less than 1 mm. The ease of use and high reliability of CT-3 dMD image fusion allows the 3D virtual head to be an accurate, realistic, and widespread tool, and has a great benefit to virtual face model.
[Design of visualized medical images network and web platform based on MeVisLab].
Xiang, Jun; Ye, Qing; Yuan, Xun
2017-04-01
With the trend of the development of "Internet +", some further requirements for the mobility of medical images have been required in the medical field. In view of this demand, this paper presents a web-based visual medical imaging platform. First, the feasibility of medical imaging is analyzed and technical points. CT (Computed Tomography) or MRI (Magnetic Resonance Imaging) images are reconstructed three-dimensionally by MeVisLab and packaged as X3D (Extensible 3D Graphics) files shown in the present paper. Then, the B/S (Browser/Server) system specially designed for 3D image is designed by using the HTML 5 and WebGL rendering engine library, and the X3D image file is parsed and rendered by the system. The results of this study showed that the platform was suitable for multiple operating systems to realize the platform-crossing and mobilization of medical image data. The development of medical imaging platform is also pointed out in this paper. It notes that web application technology will not only promote the sharing of medical image data, but also facilitate image-based medical remote consultations and distance learning.
ERIC Educational Resources Information Center
Otto, Jane Johnson
2014-01-01
The moving image plays a significant role in teaching and learning; faculty in a variety of disciplines consider it a crucial component of their coursework. Yet little has been written about how faculty identify, obtain, and use these resources and what role the library plays. This study, which engaged teaching faculty in a dialogue with library…
The browse file of NASA/JPL quick-look radar images from the Loch Linnhe 1989 experiment
NASA Technical Reports Server (NTRS)
Brown, Walter E., Jr. (Editor)
1989-01-01
The Jet Propulsion Laboratory (JPL) Aircraft Synthetic Aperture Radar (AIRSAR) was deployed to Scotland to obtain radar imagery of ship wakes generated in Loch Linnhe. These observations were part of a joint US and UK experiment to study the internal waves generated by ships under partially controlled conditions. The AIRSAR was mounted on the NASA-Ames DC-8 aircraft. The data acquisition sequence consisted of 8 flights, each about 6 hours in duration, wherein 24 observations of the instrumented site were made on each flight. This Browse File provides the experimenters with a reference of the real time imagery (approximately 100 images) obtained on the 38-deg track. These radar images are copies of those obtained at the time of observation and show the general geometry of the ship wake features. To speed up processing during this flight, the images were all processed around zero Doppler, and thus azimuth ambiguities often occur when the drift angel (yaw) exceeded a few degrees. However, even with the various shortcomings, it is believed that the experimenter will find the Browse File useful in establishing a basis for further investigations.
NASA Technical Reports Server (NTRS)
Harston, Craig; Schumacher, Chris
1992-01-01
Automated schemes are needed to classify multispectral remotely sensed data. Human intelligence is often required to correctly interpret images from satellites and aircraft. Humans suceed because they use various types of cues about a scene to accurately define the contents of the image. Consequently, it follows that computer techniques that integrate and use different types of information would perform better than single source approaches. This research illustrated that multispectral signatures and topographical information could be used in concert. Significantly, this dual source tactic classified a remotely sensed image better than the multispectral classification alone. These classifications were accomplished by fusing spectral signatures with topographical information using neural network technology. A neural network was trained to classify Landsat mulitspectral signatures. A file of georeferenced ground truth classifications were used as the training criterion. The network was trained to classify urban, agriculture, range, and forest with an accuracy of 65.7 percent. Another neural network was programmed and trained to fuse these multispectral signature results with a file of georeferenced altitude data. This topological file contained 10 levels of elevations. When this nonspectral elevation information was fused with the spectral signatures, the classifications were improved to 73.7 and 75.7 percent.
BOREAS RSS-14 Level -3 Gridded Radiometer and Satellite Surface Radiation Images
NASA Technical Reports Server (NTRS)
Hall, Forrest G. (Editor); Nickeson, Jaime (Editor); Hodges, Gary; Smith, Eric A.
2000-01-01
The BOREAS RSS-14 team collected and processed GOES-7 and -8 images of the BOREAS region as part of its effort to characterize the incoming, reflected, and emitted radiation at regional scales. This data set contains surface radiation parameters, such as net radiation and net solar radiation, that have been interpolated from GOES-7 images and AMS data onto the standard BOREAS mapping grid at a resolution of 5 km N-S and E-W. While some parameters are taken directly from the AMS data set, others have been corrected according to calibrations carried out during IFC-2 in 1994. The corrected values as well as the uncorrected values are included. For example, two values of net radiation are provided: an uncorrected value (Rn), and a value that has been corrected according to the calibrations (Rn-COR). The data are provided in binary image format data files. Some of the data files on the BOREAS CD-ROMs have been compressed using the Gzip program. See section 8.2 for details. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).
DOE Office of Scientific and Technical Information (OSTI.GOV)
2009-09-01
The on cell phone software captures the images from the CMOS camera periodically, stores the pictures, and periodically transmits those images over the cellular network to the server. The cell phone software consists of several modules: CamTest.cpp, CamStarter.cpp, StreamIOHandler .cpp, and covertSmartDevice.cpp. The camera application on the SmartPhone is CamStarter, which is "the" user interface for the camera system. The CamStarter user interface allows a user to start/stop the camera application and transfer files to the server. The CamStarter application interfaces to the CamTest application through registry settings. Both the CamStarter and CamTest applications must be separately deployed on themore » smartphone to run the camera system application. When a user selects the Start button in CamStarter, CamTest is created as a process. The smartphone begins taking small pictures (CAPTURE mode), analyzing those pictures for certain conditions, and saving those pictures on the smartphone. This process will terminate when the user selects the Stop button. The camtest code spins off an asynchronous thread, StreamIOHandler, to check for pictures taken by the camera. The received image is then tested by StreamIOHandler to see if it meets certain conditions. If those conditions are met, the CamTest program is notified through the setting of a registry key value and the image is saved in a designated directory in a custom BMP file which includes a header and the image data. When the user selects the Transfer button in the CamStarter user interface, the covertsmartdevice code is created as a process. Covertsmartdevice gets all of the files in a designated directory, opens a socket connection to the server, sends each file, and then terminates.« less
NASA Astrophysics Data System (ADS)
Parker, Jay; Donnellan, Andrea; Glasscoe, Margaret; Fox, Geoffrey; Wang, Jun; Pierce, Marlon; Ma, Yu
2015-08-01
High-resolution maps of earth surface deformation are available in public archives for scientific interpretation, but are primarily available as bulky downloads on the internet. The NASA uninhabited aerial vehicle synthetic aperture radar (UAVSAR) archive of airborne radar interferograms delivers very high resolution images (approximately seven meter pixels) making remote handling of the files that much more pressing. Data exploration requiring data selection and exploratory analysis has been tedious. QuakeSim has implemented an archive of UAVSAR data in a web service and browser system based on GeoServer (http://geoserver.org). This supports a variety of services that supply consistent maps, raster image data and geographic information systems (GIS) objects including standard earthquake faults. Browsing the database is supported by initially displaying GIS-referenced thumbnail images of the radar displacement maps. Access is also provided to image metadata and links for full file downloads. One of the most widely used features is the QuakeSim line-of-sight profile tool, which calculates the radar-observed displacement (from an unwrapped interferogram product) along a line specified through a web browser. Displacement values along a profile are updated to a plot on the screen as the user interactively redefines the endpoints of the line and the sampling density. The profile and also a plot of the ground height are available as CSV (text) files for further examination, without any need to download the full radar file. Additional tools allow the user to select a polygon overlapping the radar displacement image, specify a downsampling rate and extract a modest sized grid of observations for display or for inversion, for example, the QuakeSim simplex inversion tool which estimates a consistent fault geometry and slip model.
ERIC Educational Resources Information Center
Go, Youngmi; Kang, Jinju
2015-01-01
The purpose of this study is two-fold. First, it investigates the self-images of science teaching held by early childhood pre-service teachers who took constructivism early childhood science education courses. Second, it analyzes what aspects of those courses influenced these images. The participants were eight pre-service teachers who took these…
BOREAS TE-18 Biomass Density Image of the SSA
NASA Technical Reports Server (NTRS)
Hall, Forrest G. (Editor); Knapp, David
2000-01-01
The BOREAS TE-18 team focused its efforts on using remotely sensed data to characterize the successional and disturbance dynamics of the boreal forest for use in carbon modeling. This biomass density image covers almost the entire BOREAS SSA. The pixels for which biomass density is computed include areas, that are in conifer land cover classes only. The biomass density values represent the amount of overstory biomass (i.e., tree biomass only) per unit area. It is derived from a Landsat-5 TM image collected on 02-Sep-1994. The technique that was used to create this image is very similar to the technique that was as used to create the physical classification of the SSA. The data are provided in a binary image file format. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Activity Archive Center (DAAC).
BOREAS Level-2 MAS Surface Reflectance and Temperature Images in BSQ Format
NASA Technical Reports Server (NTRS)
Hall, Forrest G. (Editor); Newcomer, Jeffrey (Editor); Lobitz, Brad; Spanner, Michael; Strub, Richard; Lobitz, Brad
2000-01-01
The BOReal Ecosystem-Atmosphere Study (BOREAS) Staff Science Aircraft Data Acquisition Program focused on providing the research teams with the remotely sensed aircraft data products they needed to compare and spatially extend point results. The MODIS Airborne Simulator (MAS) images, along with other remotely sensed data, were collected to provide spatially extensive information over the primary study areas. This information includes biophysical parameter maps such as surface reflectance and temperature. Collection of the MAS images occurred over the study areas during the 1994 field campaigns. The level-2 MAS data cover the dates of 21-Jul-1994, 24-Jul-1994, 04-Aug-1994, and 08-Aug-1994. The data are not geographically/geometrically corrected; however, files of relative X and Y coordinates for each image pixel were derived by using the C130 navigation data in a MAS scan model. The data are provided in binary image format files.
Secure web-based access to radiology: forms and databases for fast queries
NASA Astrophysics Data System (ADS)
McColl, Roderick W.; Lane, Thomas J.
2002-05-01
Currently, Web-based access to mini-PACS or similar databases commonly utilizes either JavaScript, Java applets or ActiveX controls. Many sites do not permit applets or controls or other binary objects for fear of viruses or worms sent by malicious users. In addition, the typical CGI query mechanism requires several parameters to be sent with the http GET/POST request, which may identify the patient in some way; this in unacceptable for privacy protection. Also unacceptable are pages produced by server-side scripts which can be cached by the browser, since these may also contain sensitive information. We propose a simple mechanism for access to patient information, including images, which guarantees security of information, makes it impossible to bookmark the page, or to return to the page after some defined length of time. In addition, this mechanism is simple, therefore permitting rapid access without the need to initially download an interface such as an applet or control. In addition to image display, the design of the site allows the user to view and save movies of multi-phasic data, or to construct multi-frame datasets from entire series. These capabilities make the site attractive for research purposes such as teaching file preparation.
BOREAS RSS-8 Snow Maps Derived from Landsat TM Imagery
NASA Technical Reports Server (NTRS)
Hall, Dorothy; Chang, Alfred T. C.; Foster, James L.; Chien, Janeet Y. L.; Hall, Forrest G. (Editor); Nickeson, Jaime (Editor); Smith, David E. (Technical Monitor)
2000-01-01
The Boreal Ecosystem-Atmosphere Study (BOREAS) Remote Sensing Science (RSS)-8 team utilized Landsat Thematic Mapper (TM) images to perform mapping of snow extent over the Southern Study Area (SSA). This data set consists of two Landsat TM images that were used to determine the snow-covered pixels over the BOREAS SSA on 18 Jan 1993 and on 06 Feb 1994. The data are stored in binary image format files. The RSS-08 snow map data are available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC). The data files are available on a CD-ROM (see document number 20010000884).
A land-surface Testbed for EOSDIS
NASA Technical Reports Server (NTRS)
Emery, William; Kelley, Tim
1994-01-01
The main objective of the Testbed project was to deliver satellite images via the Internet to scientific and educational users free of charge. The main method of operations was to store satellite images on a low cost tape library system, visually browse the raw satellite data, access the raw data filed, navigate the imagery through 'C' programming and X-Windows interface software, and deliver the finished image to the end user over the Internet by means of file transfer protocol methods. The conclusion is that the distribution of satellite imagery by means of the Internet is feasible, and the archiving of large data sets can be accomplished with low cost storage systems allowing multiple users.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riley, Nathan; Geissel, Matthias; Lewis, Sean M
2015-03-01
The data described in this document consist of image files of shadowgraphs of astrophysically relevant laser driven blast waves. Supporting files include Mathematica notebooks containing design calculations, tabulated experimental data and notes, and relevant publications from the open research literature. The data was obtained on the Z-Beamlet laser from July to September 2014. Selected images and calculations will be published as part of a PhD dissertation and in associated publications in the open research literature, with Sandia credited as appropriate. The authors are not aware of any restrictions that could affect the release of the data.
NASA Technical Reports Server (NTRS)
Guenther, Bruce W.; Godden, Gerald D.; Xiong, Xiao-Xiong; Knight, Edward J.; Qiu, Shi-Yue; Montgomery, Harry; Hopkins, M. M.; Khayat, Mohammad G.; Hao, Zhi-Dong; Smith, David E. (Technical Monitor)
2000-01-01
The Moderate Resolution Imaging Spectroradiometer (MODIS) radiometric calibration product is described for the thermal emissive and the reflective solar bands. Specific sensor design characteristics are identified to assist in understanding how the calibration algorithm software product is designed. The reflected solar band software products of radiance and reflectance factor both are described. The product file format is summarized and the MODIS Characterization Support Team (MCST) Homepage location for the current file format is provided.
BOREAS Level-0 ER-2 Navigation Data
NASA Technical Reports Server (NTRS)
Strub, Richard; Dominguez, Roseanne; Newcomer, Jeffrey A.; Hall, Forrest G. (Editor)
2000-01-01
The BOREAS Staff Science effort covered those activities that were BOREAS community-level activities or required uniform data collection procedures across sites and time. These activities included the acquisition, processing, and archiving of aircraft navigation/attitude data to complement the digital image data. The level-0 ER-2 navigation data files contain aircraft attitude and position information acquired during the digital image and photographic data collection missions. Temporally, the data were acquired from April to September 1994. Data were recorded at intervals of 5 seconds. The data are stored in tabular ASCII files.
SRIM User’s Manual Release 2.0
1986-03-01
scale factor :512 Complex image file : test.ci Complex image maximum magnitude : 0.142081E+01 User scified scaling factor 0.512000E+03 Comands : [F...larger (in space dimensions) blocks being used to represent the image. This is similar to grain size in photographic film . If a fine grain image is
75 FR 4310 - Credit Reforms in Organized Wholesale Electric Markets
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-27
... electricity markets typically use bilateral contracts such as the Western Systems Power Pool (WSPP) standard... scanned image format. Commenters filing electronically do not need to make a paper filing. Commenters that..., Secretary. In consideration of the foregoing, the Commission proposes to amend part 35, Chapter J, Title 18...
Use of OsiriX in developing a digital radiology teaching library.
Shamshuddin, S; Matthews, H R
2014-10-01
Widespread adoption of digital imaging in clinical practice and for the image-based examinations of the Royal College of Radiologists has created a desire to provide a digital radiology teaching library in many hospital departments around the UK. This article describes our experience of using OsiriX software in developing digital radiology teaching libraries. Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Cleaning efficacy of reciprocal and rotary systems in the removal of root canal filling material
Koçak, Mustafa Murat; Koçak, Sibel; Türker, Sevinç Aktemur; Sağlam, Baran Can
2016-01-01
Aim: The aim of this study was to compare the efficacy of hand file, nickel titanium rotary instrument, and two reciprocating instruments for removing gutta-percha and sealer from the root canals. Materials and Methods: Eighty-eight mandibular premolar teeth were used. The root canals were shaped and filled with gutta-percha and a resin-based sealer. The specimens were divided into four groups according to the technique by which the root filling material was removed: Group 1 — Wave One; Group 2 — Reciproc; Group 3 — ProTaper; and Group 4 — Gates-Glidden burs and stainless steel hand file. Then teeth were split longitudinally and photographed. The images were transferred to a computer. The ratio of remaining filling material to the root canal periphery was calculated with the aid of ImageJ software. Statistical analysis was performed using Kruskal–Wallis and Mann–Whitney tests. Results: A significant difference was found among all groups (P < 0.001). The WaveOne group demonstrated significantly less remaining filling material. The greatest amount of filling material was found in specimens where gutta-percha was removed with Gates-Glidden burs and stainless steel hand file. Conclusion: The reciprocating files were found to be significantly more effective in removing the filling material from the canal walls compared to the rotational file and hand file. PMID:27099429
View_SPECPR: Software for Plotting Spectra (Installation Manual and User's Guide, Version 1.2)
Kokaly, Raymond F.
2008-01-01
This document describes procedures for installing and using the 'View_SPECPR' software system to plot spectra stored in SPECPR (SPECtrum Processing Routines) files. The View_SPECPR software is comprised of programs written in IDL (Interactive Data Language) that run within the ENVI (ENvironment for Visualizing Images) image processing system. SPECPR files are used by earth-remote-sensing scientists and planetary scientists for storing spectra collected by laboratory, field, and remote sensing instruments. A widely distributed SPECPR file is the U.S. Geological Survey (USGS) spectral library that contains thousands of spectra of minerals, vegetation, and man-made materials (Clark and others, 2007). SPECPR files contain reflectance data and associated wavelength and spectral resolution data, as well as meta-data on the time and date of collection and spectrometer settings. Furthermore, the SPECPR file automatically tracks changes to data records through its 'history' fields. For more details on the format and content of SPECPR files, see Clark (1993). For more details on ENVI, see ITT (2008). This program has been updated using an ENVI 4.5/IDL7.0 full license operating on a Windows XP operating system and requires the installation of the iTools components of IDL7.0; however, this program should work with full licenses on UNIX/LINUX systems. This software has not been tested with ENVI licenses on Windows Vista or Apple Operating Systems.
ERIC Educational Resources Information Center
Hasper, Eric; Windhorst, Rogier; Hedgpeth, Terri; Van Tuyl, Leanne; Gonzales, Ashleigh; Martinez, Britta; Yu, Hongyu; Farkas, Zolton; Baluch, Debra P.
2015-01-01
Project 3D IMAGINE or 3D Image Arrays to Graphically Implement New Education is a pilot study that researches the effectiveness of incorporating 3D tactile images, which are critical for learning science, technology, engineering, and mathematics, into entry-level lab courses. The focus of this project is to increase the participation and…
Planetary Image Geometry Library
NASA Technical Reports Server (NTRS)
Deen, Robert C.; Pariser, Oleg
2010-01-01
The Planetary Image Geometry (PIG) library is a multi-mission library used for projecting images (EDRs, or Experiment Data Records) and managing their geometry for in-situ missions. A collection of models describes cameras and their articulation, allowing application programs such as mosaickers, terrain generators, and pointing correction tools to be written in a multi-mission manner, without any knowledge of parameters specific to the supported missions. Camera model objects allow transformation of image coordinates to and from view vectors in XYZ space. Pointing models, specific to each mission, describe how to orient the camera models based on telemetry or other information. Surface models describe the surface in general terms. Coordinate system objects manage the various coordinate systems involved in most missions. File objects manage access to metadata (labels, including telemetry information) in the input EDRs and RDRs (Reduced Data Records). Label models manage metadata information in output files. Site objects keep track of different locations where the spacecraft might be at a given time. Radiometry models allow correction of radiometry for an image. Mission objects contain basic mission parameters. Pointing adjustment ("nav") files allow pointing to be corrected. The object-oriented structure (C++) makes it easy to subclass just the pieces of the library that are truly mission-specific. Typically, this involves just the pointing model and coordinate systems, and parts of the file model. Once the library was developed (initially for Mars Polar Lander, MPL), adding new missions ranged from two days to a few months, resulting in significant cost savings as compared to rewriting all the application programs for each mission. Currently supported missions include Mars Pathfinder (MPF), MPL, Mars Exploration Rover (MER), Phoenix, and Mars Science Lab (MSL). Applications based on this library create the majority of operational image RDRs for those missions. A Java wrapper around the library allows parts of it to be used from Java code (via a native JNI interface). Future conversions of all or part of the library to Java are contemplated.
Xia, Ling-yun; Leng, Wei-dong; Mao, Min; Yang, Guo-biao; Xiang, Yong-gang; Chen, Xin-mei
2009-08-01
To observe the formation of canal aberrations in S-shaped root canals prepared by every file of hand-used ProTaper. Fifteen S-shaped simulated resin root canals were selected. Each root canal was prepared by every file of hand-used ProTaper following the manufacturer instruction. The images of canals prepared by S1, S2, F1, F2 and F3 were taken and stored, which were divided into group S1, S2, F1, F2 and F3. One image of canal unprepared was superposed with the images of the same root canal in these five groups respectively to observe the types and number of canal aberrations, which included unprepared area, danger zone, ledge, elbow, zip and perforation. SPSS12.0 software pakage was used for Fisher's exact probabilities in 2x2 table. Unprepared area decreased following preparation by every file of ProTaper, but it still existed when the canal preparation was finished. The incidence of danger zone, elbow and zip in group F1 was 15/15, 11/15, 4/15, respectively, which was significantly higher than that in group S2(2/15,0,0) (P<0.001). Ledge appeared after prepared by F2, and increased sharply in group F3. None perforation was found in all groups. The incidence of canal aberrations begins to increase after prepared by finishing files of ProTaper.The presence of unprepared area suggests that it is essential to rinse canal abundantly during complicated canal preparation and canal antisepsis after preparation.
Designing for Peta-Scale in the LSST Database
NASA Astrophysics Data System (ADS)
Kantor, J.; Axelrod, T.; Becla, J.; Cook, K.; Nikolaev, S.; Gray, J.; Plante, R.; Nieto-Santisteban, M.; Szalay, A.; Thakar, A.
2007-10-01
The Large Synoptic Survey Telescope (LSST), a proposed ground-based 8.4 m telescope with a 10 deg^2 field of view, will generate 15 TB of raw images every observing night. When calibration and processed data are added, the image archive, catalogs, and meta-data will grow 15 PB yr^{-1} on average. The LSST Data Management System (DMS) must capture, process, store, index, replicate, and provide open access to this data. Alerts must be triggered within 30 s of data acquisition. To do this in real-time at these data volumes will require advances in data management, database, and file system techniques. This paper describes the design of the LSST DMS and emphasizes features for peta-scale data. The LSST DMS will employ a combination of distributed database and file systems, with schema, partitioning, and indexing oriented for parallel operations. Image files are stored in a distributed file system with references to, and meta-data from, each file stored in the databases. The schema design supports pipeline processing, rapid ingest, and efficient query. Vertical partitioning reduces disk input/output requirements, horizontal partitioning allows parallel data access using arrays of servers and disks. Indexing is extensive, utilizing both conventional RAM-resident indexes and column-narrow, row-deep tag tables/covering indices that are extracted from tables that contain many more attributes. The DMS Data Access Framework is encapsulated in a middleware framework to provide a uniform service interface to all framework capabilities. This framework will provide the automated work-flow, replication, and data analysis capabilities necessary to make data processing and data quality analysis feasible at this scale.
Low-Speed Fingerprint Image Capture System User`s Guide, June 1, 1993
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whitus, B.R.; Goddard, J.S.; Jatko, W.B.
1993-06-01
The Low-Speed Fingerprint Image Capture System (LS-FICS) uses a Sun workstation controlling a Lenzar ElectroOptics Opacity 1000 imaging system to digitize fingerprint card images to support the Federal Bureau of Investigation`s (FBI`s) Automated Fingerprint Identification System (AFIS) program. The system also supports the operations performed by the Oak Ridge National Laboratory- (ORNL-) developed Image Transmission Network (ITN) prototype card scanning system. The input to the system is a single FBI fingerprint card of the agreed-upon standard format and a user-specified identification number. The output is a file formatted to be compatible with the National Institute of Standards and Technology (NIST)more » draft standard for fingerprint data exchange dated June 10, 1992. These NIST compatible files contain the required print and text images. The LS-FICS is designed to provide the FBI with the capability of scanning fingerprint cards into a digital format. The FBI will replicate the system to generate a data base of test images. The Host Workstation contains the image data paths and the compression algorithm. A local area network interface, disk storage, and tape drive are used for the image storage and retrieval, and the Lenzar Opacity 1000 scanner is used to acquire the image. The scanner is capable of resolving 500 pixels/in. in both x and y directions. The print images are maintained in full 8-bit gray scale and compressed with an FBI-approved wavelet-based compression algorithm. The text fields are downsampled to 250 pixels/in. and 2-bit gray scale. The text images are then compressed using a lossless Huffman coding scheme. The text fields retrieved from the output files are easily interpreted when displayed on the screen. Detailed procedures are provided for system calibration and operation. Software tools are provided to verify proper system operation.« less
Hwang, Young-Hye; Bae, Kwang-Shik; Baek, Seung-Ho; Kum, Kee-Yeon; Lee, WooCheol; Shon, Won-Jun; Chang, Seok Woo
2014-08-01
This study used micro-computed tomographic imaging to compare the shaping ability of Mtwo (VDW, Munich, Germany), a conventional nickel-titanium file system, and Reciproc (VDW), a reciprocating file system morphologically similar to Mtwo. Root canal shaping was performed on the mesiobuccal and distobuccal canals of extracted maxillary molars. In the RR group (n = 15), Reciproc was used in a reciprocating motion (150° counterclockwise/30° clockwise, 300 rpm); in the MR group, Mtwo was used in a reciprocating motion (150° clockwise/30° counterclockwise, 300 rpm); and in the MC group, Mtwo was used in a continuous rotating motion (300 rpm). Micro-computed tomographic images taken before and after canal shaping were used to analyze canal volume change and the degree of transportation at the cervical, middle, and apical levels. The time required for canal shaping was recorded. Afterward, each file was analyzed using scanning electron microscopy. No statistically significant differences were found among the 3 groups in the time for canal shaping or canal volume change (P > .05). Transportation values of the RR and MR groups were not significantly different at any level. However, the transportation value of the MC group was significantly higher than both the RR and MR groups at the cervical and apical levels (P < .05). In the scanning electron microscopic analysis, file deformation was observed for 1 file in group RR (1/15), 3 files in group MR (3/15), and 5 files in group MC (5/15). In terms of shaping ability, Mtwo used in a reciprocating motion was not significantly different from the Reciproc system. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
BOREAS Level-1B MAS Imagery At-sensor Radiance, Relative X and Y Coordinates
NASA Technical Reports Server (NTRS)
Strub, Richard; Strub, Richard; Newcomer, Jeffrey A.; Ungar, Stephen
2000-01-01
For BOReal Ecosystem-Atmosphere Study (BOREAS), the MODIS Airborne Simulator (MAS) images, along with the other remotely sensed data, were collected to provide spatially extensive information over the primary study areas. This information includes detailed land cover and biophysical parameter maps such as fraction of Photosynthetically Active Radiation (fPAR) and Leaf Area Index (LAI). Collection of the MAS images occurred over the study areas during the 1994 field campaigns. The level-1b MAS data cover the dates of 21-Jul-1994, 24-Jul-1994, 04-Aug-1994, and 08-Aug-1994. The data are not geographically/geometrically corrected; however, files of relative X and Y coordinates for each image pixel were derived by using the C-130 INS data in a MAS scan model. The data are provided in binary image format files.
MSL: Facilitating automatic and physical analysis of published scientific literature in PDF format
Ahmed, Zeeshan; Dandekar, Thomas
2018-01-01
Published scientific literature contains millions of figures, including information about the results obtained from different scientific experiments e.g. PCR-ELISA data, microarray analysis, gel electrophoresis, mass spectrometry data, DNA/RNA sequencing, diagnostic imaging (CT/MRI and ultrasound scans), and medicinal imaging like electroencephalography (EEG), magnetoencephalography (MEG), echocardiography (ECG), positron-emission tomography (PET) images. The importance of biomedical figures has been widely recognized in scientific and medicine communities, as they play a vital role in providing major original data, experimental and computational results in concise form. One major challenge for implementing a system for scientific literature analysis is extracting and analyzing text and figures from published PDF files by physical and logical document analysis. Here we present a product line architecture based bioinformatics tool ‘Mining Scientific Literature (MSL)’, which supports the extraction of text and images by interpreting all kinds of published PDF files using advanced data mining and image processing techniques. It provides modules for the marginalization of extracted text based on different coordinates and keywords, visualization of extracted figures and extraction of embedded text from all kinds of biological and biomedical figures using applied Optimal Character Recognition (OCR). Moreover, for further analysis and usage, it generates the system’s output in different formats including text, PDF, XML and images files. Hence, MSL is an easy to install and use analysis tool to interpret published scientific literature in PDF format. PMID:29721305
Cloud Optimized Image Format and Compression
NASA Astrophysics Data System (ADS)
Becker, P.; Plesea, L.; Maurer, T.
2015-04-01
Cloud based image storage and processing requires revaluation of formats and processing methods. For the true value of the massive volumes of earth observation data to be realized, the image data needs to be accessible from the cloud. Traditional file formats such as TIF and NITF were developed in the hay day of the desktop and assumed fast low latency file access. Other formats such as JPEG2000 provide for streaming protocols for pixel data, but still require a server to have file access. These concepts no longer truly hold in cloud based elastic storage and computation environments. This paper will provide details of a newly evolving image storage format (MRF) and compression that is optimized for cloud environments. Although the cost of storage continues to fall for large data volumes, there is still significant value in compression. For imagery data to be used in analysis and exploit the extended dynamic range of the new sensors, lossless or controlled lossy compression is of high value. Compression decreases the data volumes stored and reduces the data transferred, but the reduced data size must be balanced with the CPU required to decompress. The paper also outlines a new compression algorithm (LERC) for imagery and elevation data that optimizes this balance. Advantages of the compression include its simple to implement algorithm that enables it to be efficiently accessed using JavaScript. Combing this new cloud based image storage format and compression will help resolve some of the challenges of big image data on the internet.
Morgan, Karen L. M.; Karen A. Westphal,
2016-04-21
The U.S. Geological Survey (USGS), as part of the National Assessment of Coastal Change Hazards project, conducts baseline and storm-response photography missions to document and understand the changes in vulnerability of the Nation's coasts to extreme storms (Morgan, 2009). On September 2-3, 2012, the USGS conducted an oblique aerial photographic survey along the Alabama, Mississippi, and Louisiana barrier islands aboard a Cessna 172 (aircraft) at an altitude of 500 feet (ft) and approximately 1,000 ft offshore. This mission was flown to collect post-Hurricane Isaac data for assessing incremental changes in the beach and nearshore area since the last survey, flown in September 2008 (central Louisiana barrier islands) and June 2011 (Dauphin Island, Alabama, to Breton Island, Louisiana), and the data can be used in the assessment of future coastal change.The photographs provided in this report are Joint Photographic Experts Group (JPEG) images. ExifTool was used to add the following to the header of each photo: time of collection, Global Positioning System (GPS) latitude, GPS longitude, keywords, credit, artist (photographer), caption, copyright, and contact information. The photograph locations are an estimate of the position of the aircraft at the time the photograph was taken and do not indicate the location of any feature in the images (see the Navigation Data page). These photographs document the state of the barrier islands and other coastal features at the time of the survey. Pages containing thumbnail images of the photographs, referred to as contact sheets, were created in 5-minute segments of flight time. These segments can be found on the Photos and Maps page. Photographs can be opened directly with any JPEG-compatible image viewer by clicking on a thumbnail on the contact sheet.In addition to the photographs, a Google Earth Keyhole Markup Language (KML) file is provided and can be used to view the images by clicking on the marker and then clicking on either the thumbnail or the link above the thumbnail. The KML files were created using the photographic navigation files. These KML file(s) can be found in the kml folder.
Voting with Their Seats: Computer Laboratory Design and the Casual User
ERIC Educational Resources Information Center
Spennemann, Dirk H. R.; Atkinson, John; Cornforth, David
2007-01-01
Student computer laboratories are provided by most teaching institutions around the world; however, what is the most effective layout for such facilities? The log-in data files from computer laboratories at a regional university in Australia were analysed to determine whether there was a pattern in student seating. In particular, it was…
The New Frontier: Conquering the World Wide Web by Mule.
ERIC Educational Resources Information Center
Gresham, Morgan
1999-01-01
Examines effects of teaching hypertext markup language on students' perceptions of class goals in a networked composition classroom. Suggests sending documents via file transfer protocol by command line and viewing the Web with a textual browser shifted emphasis from writing to coding. Argues that helping students identify a balance between…
A Database Training Module for Nassau Community College Staff and Faculty.
ERIC Educational Resources Information Center
Goodman, Harriett Ziskin
A training module developed following the Instructional System Design model was implemented at Nassau Community College (NCC) to teach its administration, faculty, and staff members computer skills that would enable them to use the available computer equipment more efficiently. Using this module, each trainee designed a file to be used for the…
Story to Action: A Conversation about Literacy and Organizing
ERIC Educational Resources Information Center
Goldblatt, Eli
2008-01-01
In the summer of 2006, Open Borders Project/Proyecto Sin Fronteras, a small educational center in the heart of Latino North Philadelphia, sponsored a six-week program to teach teens from Philadelphia public schools how to plan and conduct interviews, edit audio files, and write the necessary preparatory material to produce short pieces about…
ERIC Educational Resources Information Center
Thomas, Victoria
2006-01-01
This article offers some organizational solutions to help teachers better manage their classrooms and their time. To assist with the room arrangement, notebooks, and file cabinets, teachers may find it helpful to use color coding. Most teachers will have more than one class to teach during the course of a day, and, perhaps, more than one course to…
Teaching Organizational Skills to Children with High Functioning Autism and Asperger's Syndrome
ERIC Educational Resources Information Center
Dorminy, Kimberly Powers; Luscre, Deanna; Gast, David L.
2009-01-01
A multiple baseline design across participants was used to evaluate the effectiveness of a file box system plus self-monitoring on the organizational skills of four fourth and fifth grade students with high functioning autism (HFA) and Asperger's Syndrome (AS). Instruction took place in general education classrooms and consisted of teaching…
Java Image I/O for VICAR, PDS, and ISIS
NASA Technical Reports Server (NTRS)
Deen, Robert G.; Levoe, Steven R.
2011-01-01
This library, written in Java, supports input and output of images and metadata (labels) in the VICAR, PDS image, and ISIS-2 and ISIS-3 file formats. Three levels of access exist. The first level comprises the low-level, direct access to the file. This allows an application to read and write specific image tiles, lines, or pixels and to manipulate the label data directly. This layer is analogous to the C-language "VICAR Run-Time Library" (RTL), which is the image I/O library for the (C/C++/Fortran) VICAR image processing system from JPL MIPL (Multimission Image Processing Lab). This low-level library can also be used to read and write labeled, uncompressed images stored in formats similar to VICAR, such as ISIS-2 and -3, and a subset of PDS (image format). The second level of access involves two codecs based on Java Advanced Imaging (JAI) to provide access to VICAR and PDS images in a file-format-independent manner. JAI is supplied by Sun Microsystems as an extension to desktop Java, and has a number of codecs for formats such as GIF, TIFF, JPEG, etc. Although Sun has deprecated the codec mechanism (replaced by IIO), it is still used in many places. The VICAR and PDS codecs allow any program written using the JAI codec spec to use VICAR or PDS images automatically, with no specific knowledge of the VICAR or PDS formats. Support for metadata (labels) is included, but is format-dependent. The PDS codec, when processing PDS images with an embedded VIAR label ("dual-labeled images," such as used for MER), presents the VICAR label in a new way that is compatible with the VICAR codec. The third level of access involves VICAR, PDS, and ISIS Image I/O plugins. The Java core includes an "Image I/O" (IIO) package that is similar in concept to the JAI codec, but is newer and more capable. Applications written to the IIO specification can use any image format for which a plug-in exists, with no specific knowledge of the format itself.
NASA Astrophysics Data System (ADS)
Armitage, D. Bruce
1999-02-01
This simulator was developed to help students beginning the study of gas chromatographic instruments to understand their operation. It is not meant to teach chromatographic theory. The instrument simulator is divided into 5 sections. One is for sample preparation. Another is used to manage carrier gases and choose a detector and column. The third sets the conditions for either isothermal or programmed temperature operation. A fourth section models manual injections, and the fifth is the autosampler. The operator has a choice among 6 columns of differing diameters and packing polarities and a choice of either isothermal or simple one-stage temperature programming. The simulator can be operated in either single-sample mode or as a 10-sample autosampler. The integrator has two modes of operation, a "dumb" mode in which only the retention time, area of the peak, and percentage area are listed and a "smart" mode that also lists the components' identities. The identities are obtained from a list of names and retention times created by the operator. Without this list only the percentages and areas are listed. The percentages are based on the areas obtained from the chromatogram and not on the actual percentages assigned during sample preparation. The data files for the compounds used in the simulator are ASCII files and can be edited easily to add more compounds than the 11 included with the simulator. A maximum of 10 components can be used in any one sample. Sample mixtures can be made on a percent-by-volume basis, but not by mass of sample per volume of solvent. A maximum of 30 compounds can be present in any one file, but the number of files is limited only by the operating system. (I suggest that not more than 20 compounds be used in any one file, as scrolling through large numbers of compounds is annoying to say the least.) File construction and layout are discussed in detail in the User's Manual. Chromatograms are generated by calculating a retention time based on the difference between the boiling point of the component and the temperature of the column. The polarity difference between the column packing and the component is also used to modify the retention time. The retention time decreases as the difference between the boiling point of the component and the temperature of the column increases, and retention time increases as the polarity of the component approaches the polarity of the column. If the temperature of the column is too low, a warning message is given and the chromatogram does not show that component. There is no "carry-over" to the next chromatogram, as might be the case for an actual instrument. Carrier-gas flow rate is fixed and is not part of the retention-time calculation. Because of this latter condition and the method used to determine retention time, this simulator is not useful for gas chromatography method development and is not intended for such use. The purpose of the simulator is to give a beginning student experience in what happens as column temperature is varied, why one might need temperature programming, why an autosampler might be useful, and the pitfalls of "smart" integrators. When students make mistakes in instrument setup with the simulator the consequences are not damaging to the simulator but might cause serious problems with a real instrument. Hardware and Software Requirements Hardware and software requirements for A GC Instrument Simulator are shown in Table 1.

Shown (right to left) are the main instrument control window and the manual injection window from A GC Instrument Simulator.
The Chandra Source Catalog : Google Earth Interface
NASA Astrophysics Data System (ADS)
Glotfelty, Kenny; McLaughlin, W.; Evans, I.; Evans, J.; Anderson, C. S.; Bonaventura, N. R.; Davis, J. E.; Doe, S. M.; Fabbiano, G.; Galle, E. C.; Gibbs, D. G., II; Grier, J. D.; Hain, R.; Hall, D. M.; Harbo, P. N.; He, H.; Houck, J. C.; Karovska, M.; Kashyap, V. L.; Lauer, J.; McCollough, M. L.; McDowell, J. C.; Miller, J. B.; Mitschang, A. W.; Morgan, D. L.; Mossman, A. E.; Nichols, J. S.; Nowak, M. A.; Plummer, D. A.; Primini, F. A.; Refsdal, B. L.; Rots, A. R.; Siemiginowska, A. L.; Sundheim, B. A.; Tibbetts, M. S.; van Stone, D. W.; Winkelman, S. L.; Zografou, P.
2009-09-01
The Chandra Source Catalog (CSC) contains multi-resolution, exposure corrected, background subtracted, full-field images that are stored as individual FITS files and as three-color JPEG files. In this poster we discuss how we took these data and were able to, with relatively minimal effort, convert them for use with the Google Earth application in its ``Sky'' mode. We will highlight some of the challenges which include converting the data to the required Mercator projection, reworking the 3-color algorithm for pipeline processing, and ways to reduce the data volume through re-binning, using color-maps, and special Keyhole Markup Language (kml) tags to only load images on-demand. The result is a collection of some 11,000 3-color images that are available for all the individual observation in the CSC Release 1. We also have made available all ˜4000 Field-of-View outlines (with per-chip regions), which turns out are trivial to produce starting with a simple dmlist command. In the first week of release, approximately 40% of the images have been accessed at least once through some 50,000 individual web hits which have served over 4Gb of data to roughly 750 users in 60+ countries. We will also highlight some future directions we are exploring, including real-time catalog access to individual source properties and eventual access to file based products such as FITS images, spectra, and light-curves.
Programmed database system at the Chang Gung Craniofacial Center: part II--digitizing photographs.
Chuang, Shiow-Shuh; Hung, Kai-Fong; de Villa, Glenda H; Chen, Philip K T; Lo, Lun-Jou; Chang, Sophia C N; Yu, Chung-Chih; Chen, Yu-Ray
2003-07-01
The archival tools used for digital images in advertising are not to fulfill the clinic requisition and are just beginning to develop. The storage of a large amount of conventional photographic slides needs a lot of space and special conditions. In spite of special precautions, degradation of the slides still occurs. The most common degradation is the appearance of fungus flecks. With the recent advances in digital technology, it is now possible to store voluminous numbers of photographs on a computer hard drive and keep them for a long time. A self-programmed interface has been developed to integrate database and image browser system that can build and locate needed files archive in a matter of seconds with the click of a button. This system requires hardware and software were market provided. There are 25,200 patients recorded in the database that involve 24,331 procedures. In the image files, there are 6,384 patients with 88,366 digital pictures files. From 1999 through 2002, NT400,000 dollars have been saved using the new system. Photographs can be managed with the integrating Database and Browse software for database archiving. This allows labeling of the individual photographs with demographic information and browsing. Digitized images are not only more efficient and economical than the conventional slide images, but they also facilitate clinical studies.
ImageJ: Image processing and analysis in Java
NASA Astrophysics Data System (ADS)
Rasband, W. S.
2012-06-01
ImageJ is a public domain Java image processing program inspired by NIH Image. It can display, edit, analyze, process, save and print 8-bit, 16-bit and 32-bit images. It can read many image formats including TIFF, GIF, JPEG, BMP, DICOM, FITS and "raw". It supports "stacks", a series of images that share a single window. It is multithreaded, so time-consuming operations such as image file reading can be performed in parallel with other operations.
Clegg, G; Roebuck, S; Steedman, D
2001-01-01
Objectives—To develop a computer based storage system for clinical images—radiographs, photographs, ECGs, text—for use in teaching, training, reference and research within an accident and emergency (A&E) department. Exploration of methods to access and utilise the data stored in the archive. Methods—Implementation of a digital image archive using flatbed scanner and digital camera as capture devices. A sophisticated coding system based on ICD 10. Storage via an "intelligent" custom interface. Results—A practical solution to the problems of clinical image storage for teaching purposes. Conclusions—We have successfully developed a digital image capture and storage system, which provides an excellent teaching facility for a busy A&E department. We have revolutionised the practice of the "hand-over meeting". PMID:11435357
Aydin, Ugur; Karataslioglu, Emrah
2017-01-01
Canal transportation is a common sequel caused by rotary instruments. The purpose of the present study is to evaluate the degree of transportation after the use of Reciproc single-file instruments with or without glide path files. Thirty resin blocks with L-shaped canals were divided into three groups ( n = 10). Group 1 - canals were prepared with Reciproc-25 file. Group 2 - glide path file-G1 was used before Reciproc. Group 3 - glide path files-G1 and G2 were used before Reciproc. Pre- and post-instrumentation images were superimposed under microscope, and resin removed from the inner and outer surfaces of the root canal was calculated throughout 10 points. Statistical analysis was performed with Kruskal-Wallis test and post hoc Dunn test. For coronal and middle one-thirds, there was no significant difference among groups ( P > 0.05). For apical section, transportation of Group 1 was significantly higher than other groups ( P < 0.05). Using glide path files before Reciproc single-file system reduced the degree of apical canal transportation.
A Framework for Automated Digital Forensic Reporting
2009-03-01
provide a simple way to extract local accounts from a full system image. Unix, Linux and the BSD variants store user accounts in the /etc/ passwd file...with hashes of the user passwords in the /etc/shadow file for linux or /etc/master.passwd for BSD. /etc/ passwd also contains mappings from usernames to... passwd file may not map directly to real-world names, it can be a crucial link in this eventual mapping. Following are two examples where it could prove
Özyürek, Taha; Tek, Vildan; Yılmaz, Koray; Uslu, Gülşah
2017-11-01
To determine the incidence of crack formation and propagation in apical root dentin after retreatment procedures performed using ProTaper Universal Retreatment (PTR), Mtwo-R, ProTaper Next (PTN), and Twisted File Adaptive (TFA) systems. The study consisted of 120 extracted mandibular premolars. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the negative control group. One hundred teeth were prepared, obturated, and then divided into 5 retreatment groups. The retreatment procedures were performed using the following files: PTR, Mtwo-R, PTN, TFA, and hand files. After filling material removal, apical enlargement was done using apical size 0.50 mm ProTaper Universal (PTU), Mtwo, PTN, TFA, and hand files. Digital images of the apical root surfaces were recorded before preparation, after preparation, after obturation, after filling removal, and after apical enlargement using a stereomicroscope. The images were then inspected for the presence of new apical cracks and crack propagation. Data were analyzed with χ 2 tests using SPSS 21.0 software. New cracks and crack propagation occurred in all the experimental groups during the retreatment process. Nickel-titanium rotary file systems caused significantly more apical crack formation and propagation than the hand files. The PTU system caused significantly more apical cracks than the other groups after the apical enlargement stage. This study showed that retreatment procedures and apical enlargement after the use of retreatment files can cause crack formation and propagation in apical dentin.
A software to digital image processing to be used in the voxel phantom development.
Vieira, J W; Lima, F R A
2009-11-15
Anthropomorphic models used in computational dosimetry, also denominated phantoms, are based on digital images recorded from scanning of real people by Computed Tomography (CT) or Magnetic Resonance Imaging (MRI). The voxel phantom construction requests computational processing for transformations of image formats, to compact two-dimensional (2-D) images forming of three-dimensional (3-D) matrices, image sampling and quantization, image enhancement, restoration and segmentation, among others. Hardly the researcher of computational dosimetry will find all these available abilities in single software, and almost always this difficulty presents as a result the decrease of the rhythm of his researches or the use, sometimes inadequate, of alternative tools. The need to integrate the several tasks mentioned above to obtain an image that can be used in an exposure computational model motivated the development of the Digital Image Processing (DIP) software, mainly to solve particular problems in Dissertations and Thesis developed by members of the Grupo de Pesquisa em Dosimetria Numérica (GDN/CNPq). Because of this particular objective, the software uses the Portuguese idiom in their implementations and interfaces. This paper presents the second version of the DIP, whose main changes are the more formal organization on menus and menu items, and menu for digital image segmentation. Currently, the DIP contains the menus Fundamentos, Visualizações, Domínio Espacial, Domínio de Frequências, Segmentações and Estudos. Each menu contains items and sub-items with functionalities that, usually, request an image as input and produce an image or an attribute in the output. The DIP reads edits and writes binary files containing the 3-D matrix corresponding to a stack of axial images from a given geometry that can be a human body or other volume of interest. It also can read any type of computational image and to make conversions. When the task involves only an output image, this is saved as a JPEG file in the Windows default; when it involves an image stack, the output binary file is denominated SGI (Simulações Gráficas Interativas (Interactive Graphic Simulations), an acronym already used in other publications of the GDN/CNPq.
Development of the SOFIA Image Processing Tool
NASA Technical Reports Server (NTRS)
Adams, Alexander N.
2011-01-01
The Stratospheric Observatory for Infrared Astronomy (SOFIA) is a Boeing 747SP carrying a 2.5 meter infrared telescope capable of operating between at altitudes of between twelve and fourteen kilometers, which is above more than 99 percent of the water vapor in the atmosphere. The ability to make observations above most water vapor coupled with the ability to make observations from anywhere, anytime, make SOFIA one of the world s premiere infrared observatories. SOFIA uses three visible light CCD imagers to assist in pointing the telescope. The data from these imagers is stored in archive files as is housekeeping data, which contains information such as boresight and area of interest locations. A tool that could both extract and process data from the archive files was developed.
BOREAS TE-18 Landsat TM Maximum Likelihood Classification Image of the NSA
NASA Technical Reports Server (NTRS)
Hall, Forrest G. (Editor); Knapp, David
2000-01-01
The BOREAS TE-18 team focused its efforts on using remotely sensed data to characterize the successional and disturbance dynamics of the boreal forest for use in carbon modeling. The objective of this classification is to provide the BOREAS investigators with a data product that characterizes the land cover of the NSA. A Landsat-5 TM image from 20-Aug-1988 was used to derive this classification. A standard supervised maximum likelihood classification approach was used to produce this classification. The data are provided in a binary image format file. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Activity Archive Center (DAAC).
37 CFR 2.53 - Requirements for drawings filed through the TEAS.
Code of Federal Regulations, 2013 CFR
2013-07-01
... attach a digitized image of the mark to the TEAS submission that meets the requirements of paragraph (c) of this section. (c) Requirements for digitized image: The image must be in .jpg format and scanned... crowded, and produce a high quality image when copied. [68 FR 55764, Sept. 26, 2003, as amended at 70 FR...
37 CFR 2.53 - Requirements for drawings filed through the TEAS.
Code of Federal Regulations, 2012 CFR
2012-07-01
... attach a digitized image of the mark to the TEAS submission that meets the requirements of paragraph (c) of this section. (c) Requirements for digitized image: The image must be in .jpg format and scanned... crowded, and produce a high quality image when copied. [68 FR 55764, Sept. 26, 2003, as amended at 70 FR...
37 CFR 2.53 - Requirements for drawings filed through the TEAS.
Code of Federal Regulations, 2011 CFR
2011-07-01
... attach a digitized image of the mark to the TEAS submission that meets the requirements of paragraph (c) of this section. (c) Requirements for digitized image: The image must be in .jpg format and scanned... crowded, and produce a high quality image when copied. [68 FR 55764, Sept. 26, 2003, as amended at 70 FR...
37 CFR 2.53 - Requirements for drawings filed through the TEAS.
Code of Federal Regulations, 2014 CFR
2014-07-01
... attach a digitized image of the mark to the TEAS submission that meets the requirements of paragraph (c) of this section. (c) Requirements for digitized image: The image must be in .jpg format and scanned... crowded, and produce a high quality image when copied. [68 FR 55764, Sept. 26, 2003, as amended at 70 FR...
3D image acquisition by fiber-based fringe projection
NASA Astrophysics Data System (ADS)
Pfeifer, Tilo; Driessen, Sascha
2005-02-01
In macroscopic production processes several measuring methods are used to assure the quality of 3D parts. Definitely, one of the most widespread techniques is the fringe projection. It"s a fast and accurate method to receive the topography of a part as a computer file which can be processed in further steps, e.g. to compare the measured part to a given CAD file. In this article it will be shown how the fringe projection method is applied to a fiber-optic system. The fringes generated by a miniaturized fringe projector (MiniRot) are first projected onto the front-end of an image guide using special optics. The image guide serves as a transmitter for the fringes in order to get them onto the surface of a micro part. A second image guide is used to observe the micro part. It"s mounted under an angle relating to the illuminating image guide so that the triangulation condition is fulfilled. With a CCD camera connected to the second image guide the projected fringes are recorded and those data is analyzed by an image processing system.
Virtual Sonography Through the Internet: Volume Compression Issues
Vilarchao-Cavia, Joseba; Troyano-Luque, Juan-Mario; Clavijo, Matilde
2001-01-01
Background Three-dimensional ultrasound images allow virtual sonography even at a distance. However, the size of final 3-D files limits their transmission through slow networks such as the Internet. Objective To analyze compression techniques that transform ultrasound images into small 3-D volumes that can be transmitted through the Internet without loss of relevant medical information. Methods Samples were selected from ultrasound examinations performed during, 1999-2000, in the Obstetrics and Gynecology Department at the University Hospital in La Laguna, Canary Islands, Spain. The conventional ultrasound video output was recorded at 25 fps (frames per second) on a PC, producing 100- to 120-MB files (for from 500 to 550 frames). Processing to obtain 3-D images progressively reduced file size. Results The original frames passed through different compression stages: selecting the region of interest, rendering techniques, and compression for storage. Final 3-D volumes reached 1:25 compression rates (1.5- to 2-MB files). Those volumes need 7 to 8 minutes to be transmitted through the Internet at a mean data throughput of 6.6 Kbytes per second. At the receiving site, virtual sonography is possible using orthogonal projections or oblique cuts. Conclusions Modern volume-rendering techniques allowed distant virtual sonography through the Internet. This is the result of their efficient data compression that maintains its attractiveness as a main criterion for distant diagnosis. PMID:11720963
Teaching Field Biology with Photography
ERIC Educational Resources Information Center
Jenkins, Ronald L.; Howell, W. Mike; Davenport, L. J.; Wood, Linda F.
2003-01-01
Photography makes an easy and excellent tool for teaching field biology courses, allowing students to study nature without harming it. This photographic technique is used in capturing images of vertebrates, invertebrates, and plants during class field trips, then making these images available for students to identify and study from a departmental…
Transmitting Musical Images: Using Music to Teach Public Speaking
ERIC Educational Resources Information Center
Cohen, Steven D.; Wei, Thomas E.
2010-01-01
Oral communication courses traditionally help students identify the proper arrangement of words to convey particular images. Although instructors emphasize the importance of speaking powerfully, they often struggle to find effective ways to teach their students "how" to deliver a message that resonates with the audience. Given the clear importance…
Koyama, Shinzo; Onozawa, Kazutoshi; Tanaka, Keisuke; Saito, Shigeru; Kourkouss, Sahim Mohamed; Kato, Yoshihisa
2016-08-08
We developed multiocular 1/3-inch 2.75-μm-pixel-size 2.1M- pixel image sensors by co-design of both on-chip beam-splitter and 100-nm-width 800-nm-depth patterned inner meta-micro-lens for single-main-lens stereo camera systems. A camera with the multiocular image sensor can capture horizontally one-dimensional light filed by both the on-chip beam-splitter horizontally dividing ray according to incident angle, and the inner meta-micro-lens collecting the divided ray into pixel with small optical loss. Cross-talks between adjacent light field images of a fabricated binocular image sensor and of a quad-ocular image sensor are as low as 6% and 7% respectively. With the selection of two images from one-dimensional light filed images, a selective baseline for stereo vision is realized to view close objects with single-main-lens. In addition, by adding multiple light field images with different ratios, baseline distance can be tuned within an aperture of a main lens. We suggest the electrically selective or tunable baseline stereo vision to reduce 3D fatigue of viewers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yorkey, T.J.
This note describes how to get POSTSCRIPT files into T{sub E}X documents on a Sun computer using psifg. Several applications generating POSTSCRIPT files are used as examples. These applications are: Adobe Illustrator, Mathematica, View, Cricket Graph and MacDraw, and a scanned image. I assume the reader knows nothing about POSTSCRIPT, and does not want to learn anything about it.
NASA Astrophysics Data System (ADS)
Aubele, J. C.; Stanley, J.; Grochowski, A.; Jones, K.; Aragon, J.
2006-12-01
Learning opportunities can be exceptionally successful when linked to national, newsworthy events. Planetary missions are particularly exciting in engaging teachers, and their students, because they combine the human "stories" of scientists and engineers with cutting-edge technology and new science. Planetary suface missions, such as the Mars Exploration Rover (MER) mission, return beautiful and human-scale images that can virtually transport the viewer to another world. The MER mission allows children and adults to participate in the exploration of one of our nearest neighbors in space. New discoveries in the natural history of Mars have been used as the basis of a new integrated curriculum created by Museum and class-room educators designed to serve informal (family learning) and formal (classroom) audiences. The curriculum uses Mars and the MER mission as a "hook" to teach a wide range of topics that relate to all of the sciences, mathematics, social studies (history and exploration), science and society, career readiness, language and literacy, and visual arts. The curriculum, entitled "Making Tracks on Mars: Teacher Resource and Activity Guide," includes the following key features that have contributed to its success and usefulness: (1) basic information about Mars, Mars missions, and the MER mission providing teachers with the knowledge they may lack; (2) activities that follow a standardized format and include necessary information, pre-lesson preparation and post-lesson closure and extensions, and all information and/or images needed; (3) activities that cross the curriculum and can be used to address many different standards; (4) relevant state and national standards listed for each activity; (5) annotated MER image file and PowerPoint presentation for easy classroom use; (6) lists of additional Mars-related resources; (7) emphasis on local connections to the mission to enable teachers and students to feel personally connected; (8) elementary through high school classroom teachers as co-authors and co-developers of the curriculum; (9) evaluation and assessement by "pilot program" teachers; and (10) collaboration and partnership with other local and regional science education providers, such as SCORE, which provided partial funding and dissemination support, and NM MESA, a statewide organization of teachers.
McKnight, Colin D; Kelly, Aine M; Petrou, Myria; Nidecker, Anna E; Lorincz, Matthew T; Altaee, Duaa K; Gebarski, Stephen S; Foerster, Bradley
2017-06-01
Infectious encephalitis is a relatively common cause of morbidity and mortality. Treatment of infectious encephalitis with antiviral medication can be highly effective when administered promptly. Clinical mimics of encephalitis arise from a broad range of pathologic processes, including toxic, metabolic, neoplastic, autoimmune, and cardiovascular etiologies. These mimics need to be rapidly differentiated from infectious encephalitis to appropriately manage the correct etiology; however, the many overlapping signs of these various entities present a challenge to accurate diagnosis. A systematic approach that considers both the clinical manifestations and the imaging findings of infectious encephalitis and its mimics can contribute to more accurate and timely diagnosis. Following an institutional review board approval, a health insurance portability and accountability act (HIPAA)-compliant search of our institutional imaging database (teaching files) was conducted to generate a list of adult and pediatric patients who presented between January 1, 1995 and October 10, 2013 for imaging to evaluate possible cases of encephalitis. Pertinent medical records, including clinical notes as well as surgical and pathology reports, were reviewed and correlated with imaging findings. Clinical and imaging findings were combined to generate useful flowcharts designed to assist in distinguishing infectious encephalitis from its mimics. Key imaging features were reviewed and were placed in the context of the provided flowcharts. Four flowcharts were presented based on the primary anatomic site of imaging abnormality: group 1: temporal lobe; group 2: cerebral cortex; group 3: deep gray matter; and group 4: white matter. An approach that combines features on clinical presentation was then detailed. Imaging examples were used to demonstrate similarities and key differences. Early recognition of infectious encephalitis is critical, but can be quite complex due to diverse pathologies and overlapping features. Synthesis of both the clinical and imaging features of infectious encephalitis and its mimics is critical to a timely and accurate diagnosis. The use of the flowcharts presented in this article can further enable both clinicians and radiologists to more confidently differentiate encephalitis from its mimics and improve patient care. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
10 CFR 2.1011 - Management of electronic information.
Code of Federal Regulations, 2013 CFR
2013-01-01
... participants shall make textual (or, where non-text, image) versions of their documents available on a web... of the following acceptable formats: ASCII, native word processing (Word, WordPerfect), PDF Normal, or HTML. (iv) Image files must be formatted as TIFF CCITT G4 for bi-tonal images or PNG (Portable...
10 CFR 2.1011 - Management of electronic information.
Code of Federal Regulations, 2014 CFR
2014-01-01
... participants shall make textual (or, where non-text, image) versions of their documents available on a web... of the following acceptable formats: ASCII, native word processing (Word, WordPerfect), PDF Normal, or HTML. (iv) Image files must be formatted as TIFF CCITT G4 for bi-tonal images or PNG (Portable...
EROS Main Image File: A Picture Perfect Database for Landsat Imagery and Aerial Photography.
ERIC Educational Resources Information Center
Jack, Robert F.
1984-01-01
Describes Earth Resources Observation System online database, which provides access to computerized images of Earth obtained via satellite. Highlights include retrieval system and commands, types of images, search strategies, other online functions, and interpretation of accessions. Satellite information, sources and samples of accessions, and…
‘Gamma Anna’: a classroom demonstration for teaching the concepts of gamma imaging
NASA Astrophysics Data System (ADS)
Wolff, Nicola; Griffiths, Jennifer; Yerworth, Rebecca
2017-01-01
Gamma imaging is at the interface of medicine and physics and thus its teaching is important in both fields. Pedagogic literature highlights the benefits of interactive demonstrations in teaching: an increase in enjoyment and interest, as well as improvement in academic achievement. However gamma imaging uses radioactive sources, which are potentially dangerous and thus their use is tightly controlled. We have developed a demonstration which uses a localised exothermic reaction within a rag doll as an analogue of radioactivity. This can be safely used in classrooms to demonstrate the principles of gamma imaging. The tool is easy to make, cheap, robust and portable. The supplementary material in this paper gives teacher notes and a description of how to make the rag doll demonstrator. We have tested the tool using six participants, acting as ‘teachers’, who carried out the demonstration and described the doll as easy to use, and the ‘tumour’ clearly identifiable. The teaching tool was separately demonstrated to a group of 12 GCSE physics students and a group of 12 medical students. Feedback showed increased student engagement, enjoyment and understanding of gamma imaging. Previous research has shown that these benefits have an impact on learning and academic outcomes.
Schaap, Bryan D.
2004-01-01
As part of a program to support development of pesticide management plans for Indian Reservations, the U.S. Geological Survey has been working in cooperation with the U.S. Environmental Protection Agency to make selected information available to the Tribes or in a format easier for the Tribes to use.As a result of this program, four digital data sets related to the geology or hydrology of the Standing Rock Indian Reservation were produced as part of this report. The digital data sets are based on maps published in 1982 at the 1:250,000 scale in "Geohydrology of the Standing Rock Indian Reservation, North and South Dakota," U.S. Geological Survey Hydrologic Investigations Atlas HA-644 by L.W. Howells. The digital data sets were created by 1) scanning the appropriate map to create an image file, 2) registering the image file to real-world coordinates, 3) creating a new image file rectified to real-world coordinates, and 4) digitizing of the features of interest using the rectified image as a guide. As digital data sets, the information can be used in a geographic information system in combination with other information to help develop a pesticide management plan.
Topçuoğlu, Hüseyin Sinan; Düzgün, Salih; Kesim, Bertan; Tuncay, Oznur
2014-07-01
The aim of this study was to determine the incidence of crack initiation and propagation in apical root dentin after retreatment procedures performed by using 2 rotary retreatment systems and hand files with additional instrumentation. Eighty extracted mandibular premolars with single canals were selected. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the control group, and no preparation was performed. The remaining 60 teeth were prepared to size 35 with rotary files and filled with gutta-percha and AH Plus sealer. Specimens were then divided into 3 groups (n = 20), and retreatment procedures were performed with the following devices and techniques: ProTaper Universal retreatment files, Mtwo retreatment files, and hand files. After retreatment, the additional instrumentation was performed by using size 40 ProTaper, Mtwo, and hand files. Digital images of the apical root surface were recorded before preparation, after instrumentation, after filling, after retreatment, and after additional instrumentation. The images were then inspected for the presence of any new apical cracks and propagation. Data were analyzed with the logistic regression and Fisher exact tests. All experimental groups caused crack initiation and propagation after use of retreatment instruments. The ProTaper and Mtwo retreatment groups caused greater crack initiation and propagation than the hand instrument group (P < .05) after retreatment. Additional instrumentation with ProTaper and Mtwo instruments after the use of retreatment instruments caused crack initiation and propagation, whereas hand files caused neither crack initiation nor propagation (P < .05). This study showed that retreatment procedures and additional instrumentation after the use of retreatment files may cause crack initiation and propagation in apical dentin. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Using Purpose-Built Functions and Block Hashes to Enable Small Block and Sub-file Forensics
2010-01-01
JPEGs. We tested precarve using the nps-2009-canon2-gen6 (Garfinkel et al., 2009) disk image. The disk image was created with a 32 MB SD card and a...analysis of n-grams in the fragment. Fig. 1 e Usage of a 160 GB iPod reported by iTunes 8.2.1 (6) (top), as reported by the file system (bottom center), and...as computing with random sampling (bottom right). Note that iTunes usage actually in GiB, even though the program displays the “GB” label. Fig. 2 e
BOREAS TE-17 Production Efficiency Model Images
NASA Technical Reports Server (NTRS)
Hall, Forrest G.; Papagno, Andrea (Editor); Goetz, Scott J.; Goward, Samual N.; Prince, Stephen D.; Czajkowski, Kevin; Dubayah, Ralph O.
2000-01-01
A Boreal Ecosystem-Atmospheric Study (BOREAS) version of the Global Production Efficiency Model (http://www.inform.umd.edu/glopem/) was developed by TE-17 (Terrestrial Ecology) to generate maps of gross and net primary production, autotrophic respiration, and light use efficiency for the BOREAS region. This document provides basic information on the model and how the maps were generated. The data generated by the model are stored in binary image-format files. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).
SU-E-T-784: Using MLC Log Files for Daily IMRT Delivery Verification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stathakis, S; Defoor, D; Linden, P
2015-06-15
Purpose: To verify daily intensity modulated radiation therapy (IMRT) treatments using multi-leaf collimator (MLC) log files. Methods: The MLC log files from a NovalisTX Varian linear accelerator were used in this study. The MLC files were recorded daily for all patients undergoing IMRT or volumetric modulated arc therapy (VMAT). The first record of each patient was used as reference and all records for subsequent days were compared against the reference. An in house MATLAB software code was used for the comparisons. Each MLC log file was converted to a fluence map (FM) and a gamma index (γ) analysis was usedmore » for the evaluation of each daily delivery for every patient. The tolerance for the gamma index was set to 2% dose difference and 2mm distance to agreement while points with signal of 10% or lower of the maximum value were excluded from the comparisons. Results: The γ between each of the reference FMs and the consecutive daily fraction FMs had an average value of 99.1% (ranged from 98.2 to 100.0%). The FM images were reconstructed at various resolutions in order to study the effect of the resolution on the γ and at the same time reduce the time for processing the images. We found that the comparison of images with the highest resolution (768×1024) yielded on average a lower γ (99.1%) than the ones with low resolution (192×256) (γ 99.5%). Conclusion: We developed an in-house software that allows us to monitor the quality of daily IMRT and VMAT treatment deliveries using information from the MLC log files of the linear accelerator. The information can be analyzed and evaluated as early as after the completion of each daily treatment. Such tool can be valuable to assess the effect of MLC positioning on plan quality, especially in the context of adaptive radiotherapy.« less
Ranade, Manisha K; Lynch, Bart D; Li, Jonathan G; Dempsey, James F
2006-01-01
We have developed an electronic portal imaging device (EPID) employing a fast scintillator and a high-speed camera. The device is designed to accurately and independently characterize the fluence delivered by a linear accelerator during intensity modulated radiation therapy (IMRT) with either step-and-shoot or dynamic multileaf collimator (MLC) delivery. Our aim is to accurately obtain the beam shape and fluence of all segments delivered during IMRT, in order to study the nature of discrepancies between the plan and the delivered doses. A commercial high-speed camera was combined with a terbium-doped gadolinium-oxy-sulfide (Gd2O2S:Tb) scintillator to form an EPID for the unaliased capture of two-dimensional fluence distributions of each beam in an IMRT delivery. The high speed EPID was synchronized to the accelerator pulse-forming network and gated to capture every possible pulse emitted from the accelerator, with an approximate frame rate of 360 frames-per-second (fps). A 62-segment beam from a head-and-neck IMRT treatment plan requiring 68 s to deliver was recorded with our high speed EPID producing approximately 6 Gbytes of imaging data. The EPID data were compared with the MLC instruction files and the MLC controller log files. The frames were binned to provide a frame rate of 72 fps with a signal-to-noise ratio that was sufficient to resolve leaf positions and segment fluence. The fractional fluence from the log files and EPID data agreed well. An ambiguity in the motion of the MLC during beam on was resolved. The log files reported leaf motions at the end of 33 of the 42 segments, while the EPID observed leaf motions in only 7 of the 42 segments. The static IMRT segment shapes observed by the high speed EPID were in good agreement with the shapes reported in the log files. The leaf motions observed during beam-on for step-and-shoot delivery were not temporally resolved by the log files.
2008-02-15
THIS IMAGE SHOWS THE DEVELOPMENT AND CONSTRUCTION OF THE A3 TEST STAND IN SUPPORT OF THE ARES/CLV UPPER STAGE ENGINE AT STENNIS SPACE CENTER, MISSISSIPPI. THIS IMAGE IS EXTRACTED FROM A HIGH DEFINITION VIDEO FILE AND IS THE HIGHEST RESOLUTION AVAILABLE.
Loh, N. Duane
2012-06-20
This deposition includes the aerosol diffraction images used for phasing, fractal morphology, and time-of-flight mass spectrometry. Files in this deposition are ordered in subdirectories that reflect the specifics.
BOREAS TE-18 Landsat TM Physical Classification Image of the NSA
NASA Technical Reports Server (NTRS)
Hall, Forrest G. (Editor); Knapp, David
2000-01-01
The BOREAS TE-18 team focused its efforts on using remotely sensed data to characterize the successional and disturbance dynamics of the boreal forest for use in carbon modeling. The objective of this classification is to provide the BOREAS investigators with a data product that characterizes the land cover of the NSA. A Landsat-5 TM image from 21-Jun-1995 was used to derive the classification. A technique was implemented that uses reflectances of various land cover types along with a geometric optical canopy model to produce spectral trajectories. These trajectories are used in a way that is similar to training data to classify the image into the different land cover classes. The data are provided in a binary, image file format. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).
BOREAS TE-18 Landsat TM Physical Classification Image of the SSA
NASA Technical Reports Server (NTRS)
Hall, Forrest G. (Editor); Knapp, David
2000-01-01
The BOREAS TE-18 team focused its efforts on using remotely sensed data to characterize the successional and disturbance dynamics of the boreal forest for use in carbon modeling. The objective of this classification is to provide the BOREAS investigators with a data product that characterizes the land cover of the SSA. A Landsat-5 TM image from 02-Sep-1994 was used to derive the classification. A technique was implemented that uses reflectances of various land cover types along with a geometric optical canopy model to produce spectral trajectories. These trajectories are used as training data to classify the image into the different land cover classes. These data are provided in a binary image file format. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Activity Archive Center (DAAC).
BOREAS TE-18 Landsat TM Maximum Likelihood Classification Image of the SSA
NASA Technical Reports Server (NTRS)
Hall, Forrest G. (Editor); Knapp, David
2000-01-01
The BOREAS TE-18 team focused its efforts on using remotely sensed data to characterize the successional and disturbance dynamics of the boreal forest for use in carbon modeling. The objective of this classification is to provide the BOREAS investigators with a data product that characterizes the land cover of the SSA. A Landsat-5 TM image from 02-Sep- 1994 was used to derive the classification. A technique was implemented that uses reflectances of various land cover types along with a geometric optical canopy model to produce spectral trajectories. These trajectories are used as training data to classify the image into the different land cover classes. These data are provided in a binary image file format. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Active Center (DAAC).
BOREAS Level-2 NS001 TMS Imagery: Reflectance and Temperature in BSQ Format
NASA Technical Reports Server (NTRS)
Lobitz, Brad; Spanner, Michael; Hall, Forrest G. (Editor); Newcomer, Jeffrey A. (Editor); Strub, Richard
2000-01-01
For BOREAS, the NS001 TMS images, along with the other remotely sensed data, were collected to provide spatially extensive information over the primary study areas. This information includes detailed land cover and biophysical parameter maps such as fPAR and LAI. Collection of the NS001 images occurred over the study areas during the 1994 field campaigns. The level-2 NS001 data are atmospherically corrected versions of some of the best original NS001 imagery and cover the dates of 19-Apr-1994, 07-Jun-1994, 21-Jul-1994, 08-Aug-1994, and 16-Sep-1994. The data are not geographically/geometrically corrected; however, files of relative X and Y coordinates for each image pixel were derived by using the C130 INS data in an NS001 scan model. The data are provided in binary image format files.
NASA Technical Reports Server (NTRS)
Miller, John; Freemantle, Jim; Nickeson, Jaime (Editor); Hall, Forrest G. (Editor); Smith, David E. (Technical Monitor)
2000-01-01
The Remote Sensing Science (RSS)-19 team collected Compact Airborne Spectrographic Imager (CASI) images from the Chieftain Navaho aircraft in order to observe the seasonal change in the radiometric reflectance properties of the boreal forest landscape. CASI was deployed as a site-specific optical sensor during Boreal Ecosystem-Atmosphere Study (BOREAS) field campaigns. Image data were collected with CASI on 36 days during five field campaigns between February and September 1994, primarily at flux tower sites located at study sites near Thompson, Manitoba, and Prince Albert, Saskatchewan. A variety of CASI data collection strategies were used to meet the following scientific objectives: 1) canopy bidirectional reflectance, 2) canopy biochemistry, 3) spatial variability, and 4) estimates of up and downwelling Photosynthetically Active Radiation (PAR) and spectral albedo, as well as changes along transects across lakes and transects the Northern Study Area (NSA) and Southern Study Area (SSA). The images are stored as binary image files. A subset of the 1994 CASI acquisitions have been compressed and included on the BOREAS CD-ROM set. This subset includes three images for the NSA-OBS (Old Black Spruce) site on 06 Jun 94, 08 Aug 94, and 06 Sep 94, one image for the SSA-OBS site on 24 Jul 94; and one image for the NSA-Fen site on 08 Aug 94. The CASI imagery on the BOREAS CD-ROMs have been compressed using the Gzip program. The rest of the 1994 BOREAS CASI archive are not contained on the BOREAS CD-ROM set. Inventory listing files are supplied on the CD-ROM to inform users of the data that were collected. The RSS-19 1994 CASI images are available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC). The data files are available on a CD-ROM (see document number 20010000884).
Video multiple watermarking technique based on image interlacing using DWT.
Ibrahim, Mohamed M; Abdel Kader, Neamat S; Zorkany, M
2014-01-01
Digital watermarking is one of the important techniques to secure digital media files in the domains of data authentication and copyright protection. In the nonblind watermarking systems, the need of the original host file in the watermark recovery operation makes an overhead over the system resources, doubles memory capacity, and doubles communications bandwidth. In this paper, a robust video multiple watermarking technique is proposed to solve this problem. This technique is based on image interlacing. In this technique, three-level discrete wavelet transform (DWT) is used as a watermark embedding/extracting domain, Arnold transform is used as a watermark encryption/decryption method, and different types of media (gray image, color image, and video) are used as watermarks. The robustness of this technique is tested by applying different types of attacks such as: geometric, noising, format-compression, and image-processing attacks. The simulation results show the effectiveness and good performance of the proposed technique in saving system resources, memory capacity, and communications bandwidth.
Sandia MEMS Visualization Tools v. 3.0
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yarberry, Victor; Jorgensen, Craig R.; Young, Andrew I.
This is a revision to the Sandia MEMS Visualization Tools. It replaces all previous versions. New features in this version: Support for AutoCAD 2014 and 2015 . This CD contains an integrated set of electronic files that: a) Provides a 2D Process Visualizer that generates cross-section images of devices constructed using the SUMMiT V fabrication process. b) Provides a 3D Visualizer that generates 3D images of devices constructed using the SUMMiT V fabrication process. c) Provides a MEMS 3D Model generator that creates 3D solid models of devices constructed using the SUMMiT V fabrication process. While there exists some filesmore » on the CD that are used in conjunction with software package AutoCAD , these files are not intended for use independent of the CD. Note that the customer must purchase his/her own copy of AutoCAD to use with these files.« less
FERMI/GLAST Integrated Trending and Plotting System Release 5.0
NASA Technical Reports Server (NTRS)
Ritter, Sheila; Brumer, Haim; Reitan, Denise
2012-01-01
An Integrated Trending and Plotting System (ITPS) is a trending, analysis, and plotting system used by space missions to determine performance and status of spacecraft and its instruments. ITPS supports several NASA mission operational control centers providing engineers, ground controllers, and scientists with access to the entire spacecraft telemetry data archive for the life of the mission, and includes a secure Web component for remote access. FERMI/GLAST ITPS Release 5.0 features include the option to display dates (yyyy/ddd) instead of orbit numbers along orbital Long-Term Trend (LTT) plot axis, the ability to save statistics from daily production plots as image files, and removal of redundant edit/create Input Definition File (IDF) screens. Other features are a fix to address invalid packet lengths, a change in naming convention of image files in order to use in script, the ability to save all ITPS plot images (from Windows or the Web) as GIF or PNG format, the ability to specify ymin and ymax on plots where previously only the desired range could be specified, Web interface capability to plot IDFs that contain out-oforder page and plot numbers, and a fix to change all default file names to show yyyydddhhmmss time stamps instead of hhmmssdddyyyy. A Web interface capability sorts files based on modification date (with newest one at top), and the statistics block can be displayed via a Web interface. Via the Web, users can graphically view the volume of telemetry data from each day contained in the ITPS archive in the Web digest. The ITPS could be also used in nonspace fields that need to plot data or trend data, including financial and banking systems, aviation and transportation systems, healthcare and educational systems, sales and marketing, and housing and construction.
Gunderman, Richard B; Wilson, Philip K
2005-08-01
For a variety of reasons, new radiological imaging techniques are supplanting traditional cadaver dissection in the teaching of human anatomy. The authors briefly review the historical forces behind this transition, and then explore the advantages and drawbacks of each approach. Cadaver dissection offers an active, hands-on exploration of human structure, provides deep insights into the meaning of human embodiment and mortality, and represents a profound rite of passage into the medical profession. Radiological imaging permits in vivo visualization, offers physiologic as well as anatomic insights, and represents the context in which contemporary practicing physicians most frequently encounter their patients' otherwise hidden internal anatomy. Despite its important strengths, radiology cannot simply substitute for cadaver dissection, and the best models for teaching gross anatomy will incorporate both cadaver dissection and radiological imaging.
Automatic Feature Extraction System.
1982-12-01
exploitation. It was used for * processing of black and white and multispectral reconnaissance photography, side-looking synthetic aperture radar imagery...the image data and different software modules for image queing and formatting, the result of the input process will be images in standard AFES file...timely manner. The FFS configuration provides the environment necessary for integrated testing of image processing functions and design and
Two American Entrepreneurs: Madame C. J. Walker and J. C. Penney. Teaching with Historic Places.
ERIC Educational Resources Information Center
Koman, Rita
2000-01-01
This lesson is based on the National Historic Landmark files, "Madame C. J. Walker Building" and "J. C. Penney Historic District," as well as other relevant sources. The lesson first discusses the Indianapolis (Indiana) site of Madame Walker's cosmetics business. The building is a 4-story brick structure completed in 1927.…
First Battle of Manassas: An End to Innocence. Teaching with Historic Places.
ERIC Educational Resources Information Center
Litterst, Michael
This lesson is based on the National Register of Historic Places registration file, "Manassas National Battlefield Park" and other sources. The lesson could be used in units on the Civil War. Students strengthen their skills of observation and interpretation in the study of history and geography and gain practice in analyzing primary…
ERIC Educational Resources Information Center
Hughes, Mary; Wilson, Sara
This lesson is based on the National Register of Historic Places registration file, "University of Virginia Historic District," and other primary and secondary materials about Thomas Jefferson and the ctreation of the University of Virginia. Thomas Jefferson did not begin the effort of designing the University of Virginia…
ERIC Educational Resources Information Center
Martin, Christopher B.; Vandehoef, Crissie; Cook, Allison
2015-01-01
A hands-on activity appropriate for first-semester general chemistry students is presented that combines traditional VSEPR methods of predicting molecular geometries with introductory use of molecular modeling. Students analyze a series of previously calculated output files consisting of several molecules each in various geometries. Each structure…
CALLing All Foreign Language Teachers: Computer-Assisted Language Learning in the Classroom
ERIC Educational Resources Information Center
Erben, Tony, Ed.; Sarieva, Iona, Ed.
2008-01-01
This book is a comprehensive guide to help foreign language teachers use technology in their classrooms. It offers the best ways to integrate technology into teaching for student-centered learning. CALL Activities include: Email; Building a Web site; Using search engines; Powerpoint; Desktop publishing; Creating sound files; iMovie; Internet chat;…
Interactivity Technologies to Improve the Learning in Classrooms through the Cloud
ERIC Educational Resources Information Center
Fardoun, Habib M.; Alghazzawi, Daniyal M.; Paules, Antonio
2018-01-01
In this paper, the authors present a cloud system that incorporate tools developed in HTML5 and JQuery technologies, which are offered to professors and students in the development of a teaching methodology called flipped classroom, where the theoretical content is usually delivered by video files and self-assessment tools that students can…
Boston's Arnold Arboretum: A Place for Study and Recreation. Teaching with Historic Places.
ERIC Educational Resources Information Center
Banks, Alan
This lesson is based on the National Register of Historic Places registration file for the Arnold Arboretum (Massachusetts) and other source material about the Arboretum and Frederick Law Olmstead. The lesson focuses on the first arboretum in the United States, which was part of Olmstead's plan for Boston's park system, known as the "Emerald…
ERIC Educational Resources Information Center
Decker, Janet R.; Pazey, Barbara L.
2017-01-01
Allegations of improper discipline are commonly the focus of special education litigation filed against school districts. Because ignorance of the law is no defense, administrators and educators must understand special education law. Yet many educators receive little to no legal training. To address the lack of training and prevent future…
Dynamic Modeling for Development and Education: From Concepts to Numbers
ERIC Educational Resources Information Center
Van Geert, Paul
2014-01-01
The general aim of the article is to teach the reader how to transform conceptual models of change, development, and learning into mathematical expressions and how to use these equations to build dynamic models by means of the widely used spreadsheet program Excel. The explanation is supported by a number of Excel files, which the reader can…
Gold Fever! Seattle Outfits the Klondike Gold Rush. Teaching with Historic Places.
ERIC Educational Resources Information Center
Blackburn, Marc K.
This lesson is based on the National Register of Historic Places registration file, "Pioneer Square Historic District," and other sources about Seattle (Washington) and the Klondike Gold Rush. The lesson helps students understand how Seattle exemplified the prosperity of the Klondike Gold Rush after 1897 when news of a gold strike in…
Glen Echo Park: Center for Education and Recreation. Teaching with Historic Places.
ERIC Educational Resources Information Center
Gray, Stephanie
This lesson is based on the National Register of Historic Places registration file "Glen Echo Amusement Park," park planning documents, and newspaper and magazine accounts. The lesson can be used in U.S. history units on the Gilded Age and the Progressive Era to explore religious and educational reform movements (including the Chautauqua…
"The Great Chief Justice" at Home. Teaching with Historic Places. Lesson Plan No. 49.
ERIC Educational Resources Information Center
Patrick, John J.
This lesson emphasizes the virtues underlying John Marshall's commitment to his duties as public official and member of a family. It is based on the National Register of Historic Places registration file "John Marshall House" and information from the John Marshall Foundation of Richmond, Virginia, and the Association for the Preservation…
NASA Astrophysics Data System (ADS)
Battisti, F.; Carli, M.; Neri, A.
2011-03-01
The increasing use of digital image-based applications is resulting in huge databases that are often difficult to use and prone to misuse and privacy concerns. These issues are especially crucial in medical applications. The most commonly adopted solution is the encryption of both the image and the patient data in separate files that are then linked. This practice results to be inefficient since, in order to retrieve patient data or analysis details, it is necessary to decrypt both files. In this contribution, an alternative solution for secure medical image annotation is presented. The proposed framework is based on the joint use of a key-dependent wavelet transform, the Integer Fibonacci-Haar transform, of a secure cryptographic scheme, and of a reversible watermarking scheme. The system allows: i) the insertion of the patient data into the encrypted image without requiring the knowledge of the original image, ii) the encryption of annotated images without causing loss in the embedded information, and iii) due to the complete reversibility of the process, it allows recovering the original image after the mark removal. Experimental results show the effectiveness of the proposed scheme.
A novel fuzzy logic-based image steganography method to ensure medical data security.
Karakış, R; Güler, I; Çapraz, I; Bilir, E
2015-12-01
This study aims to secure medical data by combining them into one file format using steganographic methods. The electroencephalogram (EEG) is selected as hidden data, and magnetic resonance (MR) images are also used as the cover image. In addition to the EEG, the message is composed of the doctor׳s comments and patient information in the file header of images. Two new image steganography methods that are based on fuzzy-logic and similarity are proposed to select the non-sequential least significant bits (LSB) of image pixels. The similarity values of the gray levels in the pixels are used to hide the message. The message is secured to prevent attacks by using lossless compression and symmetric encryption algorithms. The performance of stego image quality is measured by mean square of error (MSE), peak signal-to-noise ratio (PSNR), structural similarity measure (SSIM), universal quality index (UQI), and correlation coefficient (R). According to the obtained result, the proposed method ensures the confidentiality of the patient information, and increases data repository and transmission capacity of both MR images and EEG signals. Copyright © 2015 Elsevier Ltd. All rights reserved.
Providing Internet Access to High-Resolution Lunar Images
NASA Technical Reports Server (NTRS)
Plesea, Lucian
2008-01-01
The OnMoon server is a computer program that provides Internet access to high-resolution Lunar images, maps, and elevation data, all suitable for use in geographical information system (GIS) software for generating images, maps, and computational models of the Moon. The OnMoon server implements the Open Geospatial Consortium (OGC) Web Map Service (WMS) server protocol and supports Moon-specific extensions. Unlike other Internet map servers that provide Lunar data using an Earth coordinate system, the OnMoon server supports encoding of data in Moon-specific coordinate systems. The OnMoon server offers access to most of the available high-resolution Lunar image and elevation data. This server can generate image and map files in the tagged image file format (TIFF) or the Joint Photographic Experts Group (JPEG), 8- or 16-bit Portable Network Graphics (PNG), or Keyhole Markup Language (KML) format. Image control is provided by use of the OGC Style Layer Descriptor (SLD) protocol. Full-precision spectral arithmetic processing is also available, by use of a custom SLD extension. This server can dynamically add shaded relief based on the Lunar elevation to any image layer. This server also implements tiled WMS protocol and super-overlay KML for high-performance client application programs.
Providing Internet Access to High-Resolution Mars Images
NASA Technical Reports Server (NTRS)
Plesea, Lucian
2008-01-01
The OnMars server is a computer program that provides Internet access to high-resolution Mars images, maps, and elevation data, all suitable for use in geographical information system (GIS) software for generating images, maps, and computational models of Mars. The OnMars server is an implementation of the Open Geospatial Consortium (OGC) Web Map Service (WMS) server. Unlike other Mars Internet map servers that provide Martian data using an Earth coordinate system, the OnMars WMS server supports encoding of data in Mars-specific coordinate systems. The OnMars server offers access to most of the available high-resolution Martian image and elevation data, including an 8-meter-per-pixel uncontrolled mosaic of most of the Mars Global Surveyor (MGS) Mars Observer Camera Narrow Angle (MOCNA) image collection, which is not available elsewhere. This server can generate image and map files in the tagged image file format (TIFF), Joint Photographic Experts Group (JPEG), 8- or 16-bit Portable Network Graphics (PNG), or Keyhole Markup Language (KML) format. Image control is provided by use of the OGC Style Layer Descriptor (SLD) protocol. The OnMars server also implements tiled WMS protocol and super-overlay KML for high-performance client application programs.
ERIC Educational Resources Information Center
Jakobi, Patricia
1999-01-01
Analysis of Web site images of aging to identify positive and negative representations can help teach students about social perceptions of older adults. Another learning experience involves consideration of the needs of older adults in Web site design. (SK)