Sample records for imaging technical progress

  1. First results of ground-based LWIR hyperspectral imaging remote gas detection

    NASA Astrophysics Data System (ADS)

    Zheng, Wei-jian; Lei, Zheng-gang; Yu, Chun-chao; Wang, Hai-yang; Fu, Yan-peng; Liao, Ning-fang; Su, Jun-hong

    2014-11-01

    The new progress of ground-based long-wave infrared remote sensing is presented. The LWIR hyperspectral imaging by using the windowing spatial and temporal modulation Fourier spectroscopy, and the results of outdoor ether gas detection, verify the features of LWIR hyperspectral imaging remote sensing and technical approach. It provides a new technical means for ground-based gas remote sensing.

  2. Advanced Thermal Emission Imaging Systems Definition and Development

    NASA Technical Reports Server (NTRS)

    Blasius, Karl; Nava, David (Technical Monitor)

    2002-01-01

    Santa Barbara Remote Sensing (SBRS), Raytheon Company, is pleased to submit this quarterly progress report of the work performed in the third quarter of Year 2 of the Advanced THEMIS Project, July through September 2002. We review here progress in the proposed tasks. During July through September 2002 progress was made in two major tasks, Spectral Response Characterization and Flight Instrument Definition. Because of staffing problems and technical problems earlier in the program we have refocused the remaining time and budget on the key technical tasks. Current technical problems with a central piece of test equipment has lead us to request a 1 quarter extension to the period of performance. This request is being made through a separate letter independent of this report.

  3. The ELISE II Project: A Digital Image Library for Europe.

    ERIC Educational Resources Information Center

    Strunz, Bob; Waters, Mairead

    This paper describes the progress made under the ELISE II electronic image library project from a technical standpoint. The ELISE II project is a European-wide initiative that aims to provide a comprehensive electronic image library service for Europe. It is funded under the European Commission, DG XIII-E, Telematics for Libraries Initiative. The…

  4. Technical parameters for specifying imagery requirements

    NASA Technical Reports Server (NTRS)

    Coan, Paul P.; Dunnette, Sheri J.

    1994-01-01

    Providing visual information acquired from remote events to various operators, researchers, and practitioners has become progressively more important as the application of special skills in alien or hazardous situations increases. To provide an understanding of the technical parameters required to specify imagery, we have identified, defined, and discussed seven salient characteristics of images: spatial resolution, linearity, luminance resolution, spectral discrimination, temporal discrimination, edge definition, and signal-to-noise ratio. We then describe a generalizing imaging system and identified how various parts of the system affect the image data. To emphasize the different applications of imagery, we have constrasted the common television system with the significant parameters of a televisual imaging system for technical applications. Finally, we have established a method by which the required visual information can be specified by describing certain technical parameters which are directly related to the information content of the imagery. This method requires the user to complete a form listing all pertinent data requirements for the imagery.

  5. Nuclear medicine and imaging research. Quantitative studies in radiopharmaceutical science. Comprehensive progress report, January 1, 1983-June 30, 1985

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beck, R.N.; Cooper, M.D.

    1985-09-01

    This comprehensive report outlines the progress made during the past three years in the areas described below. In all instances, initial studies have been carried out and the technical feasibility of carrying through each study has been demonstrated. The studies described include development of cesium-130 and bromine-75 radioisotope generators, the feasibility of using rubidium-82 as a myocardial imaging agent, and radiochemical preparation of C-11 deoxyglucose. 28 refs. (DT)

  6. Symptomatic thoracic spinal cord herniation: case series and technical report.

    PubMed

    Hawasli, Ammar H; Ray, Wilson Z; Wright, Neill M

    2014-09-01

    Idiopathic spinal cord herniation (ISCH) is an uncommon condition located predominantly in the thoracic spine and often associated with a remote history of a major traumatic injury. ISCH has an incompletely described presentation and unknown etiology. There is no consensus on the treatment algorithm and surgical technique, and there are few data on clinical outcomes. In this case series and technical report, we describe the atypical myelopathy presentation, remote history of traumatic injury, radiographic progression, treatment, and outcomes of 5 patients treated at Washington University for symptomatic ISCH. A video showing surgical repair is presented. In contrast to classic compressive myelopathy symptomatology, ISCH patients presented with an atypical myelopathy, characterized by asymmetric motor and sensory deficits and early-onset urinary incontinence. Clinical deterioration correlated with progressive spinal cord displacement and herniation observed on yearly spinal imaging in a patient imaged serially because of multiple sclerosis. Finally, compared with compressive myelopathy in the thoracic spine, surgical treatment of ISCH led to rapid improvement despite a long duration of symptoms. Symptomatic ISCH presents with atypical myelopathy and slow temporal progression and can be successfully managed with surgical repair.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chisum, Brad

    This report summarizes the technical achievements that occurred over the duration of the project. On November 14th, 2014, Lumedyne Technologies Incorporated was acquired. As a result of the acquisition, the work toward seismic imaging applications was suspended indefinitely. This report captures the progress achieved up to that time.

  8. Symptomatic Thoracic Spinal Cord Herniation: Case Series and Technical Report

    PubMed Central

    Hawasli, Ammar H.; Ray, Wilson Z.; Wright, Neill M.

    2014-01-01

    Background and Importance Idiopathic spinal cord herniation (ISCH) is an uncommon condition located predominantly in the thoracic spine and often associated with a remote history of a major traumatic injury. ISCH has an incompletely described presentation and unknown etiology. There is no consensus on treatment algorithm and surgical technique, and there is little data on clinical outcomes. Clinical Presentation In this case series and technical report, we describe the atypical myelopathy presentation, remote history of traumatic injury, radiographic progression, treatment, and outcomes of 5 patients treated at Washington University for symptomatic ISCH. A video showing surgical repair is presented. In contrast to classic compressive myelopathy symptomology, ISCH patients presented with an atypical myelopathy, characterized by asymmetric motor and sensory deficits and early-onset urinary incontinence. Clinical deterioration correlated with progressive spinal cord displacement and herniation observed on yearly spinal imaging in a patient imaged serially due to multiple sclerosis. Finally compared to compressive myelopathy in the thoracic spine, surgical treatment of ISH led to rapid improvement despite long duration of symptoms. Conclusion Symptomatic ISCH presents with atypical myelopathy and slow temporal progression and can be successfully managed with surgical repair. PMID:24871148

  9. Imaging of the peripheral retina

    PubMed Central

    Kernt, Marcus; Kampik, Anselm

    2013-01-01

    The technical progress of the recent years has revolutionized imaging in ophthalmology. Scanning laser ophthalmoscopy (SLO), digital angiography, optical coherence tomography (OCT), and detection of fundus autofluorescence (FAF) have fundamentally changed our understanding of numerous retinal and choroidal diseases. Besides the tremendous advances in macular diagnostics, there is more and more evidence that central pathologies are often directly linked to changes in the peripheral retina. This review provides a brief overview on current posterior segment imaging techniques with a special focus on the peripheral retina. PMID:24391370

  10. Coherent X-Ray Diffraction Imaging and Characterization of Strain in Silicon-on-Insulator Nanostructures

    PubMed Central

    Xiong, Gang; Moutanabbir, Oussama; Reiche, Manfred; Harder, Ross; Robinson, Ian

    2014-01-01

    Coherent X-ray diffraction imaging (CDI) has emerged in the last decade as a promising high resolution lens-less imaging approach for the characterization of various samples. It has made significant technical progress through developments in source, algorithm and imaging methodologies thus enabling important scientific breakthroughs in a broad range of disciplines. In this report, we will introduce the principles of forward scattering CDI and Bragg geometry CDI (BCDI), with an emphasis on the latter. BCDI exploits the ultra-high sensitivity of the diffraction pattern to the distortions of crystalline lattice. Its ability of imaging strain on the nanometer scale in three dimensions is highly novel. We will present the latest progress on the application of BCDI in investigating the strain relaxation behavior in nanoscale patterned strained silicon-on-insulator (sSOI) materials, aiming to understand and engineer strain for the design and implementation of new generation semiconductor devices. PMID:24955950

  11. 48 CFR 2052.211-71 - Technical progress report.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Technical progress report... Technical progress report. As prescribed at 2011.104-70(b), the contracting officer shall insert the... solicitation. Technical Progress Report (JAN 1993) The contractor shall provide a monthly Technical Progress...

  12. 48 CFR 2052.211-71 - Technical progress report.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false Technical progress report... Technical progress report. As prescribed at 2011.104-70(b), the contracting officer shall insert the... solicitation. Technical Progress Report (JAN 1993) The contractor shall provide a monthly Technical Progress...

  13. 48 CFR 2052.211-71 - Technical progress report.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Technical progress report... Technical progress report. As prescribed at 2011.104-70(b), the contracting officer shall insert the... solicitation. Technical Progress Report (JAN 1993) The contractor shall provide a monthly Technical Progress...

  14. 48 CFR 2052.211-71 - Technical progress report.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Technical progress report... Technical progress report. As prescribed at 2011.104-70(b), the contracting officer shall insert the... solicitation. Technical Progress Report (JAN 1993) The contractor shall provide a monthly Technical Progress...

  15. The patient-sensor interface

    PubMed Central

    Crockett, G. S.

    1970-01-01

    During the assessment of monitoring equipment on acute medical cases in a general ward, a quantitative investigation of technical faults revealed that 44% of these occurred at the patient-sensor interface. While the attachment of the equipment was accepted by the patient and was suitable for application by nursing staff, this degree of technical breakdown indicates that more progress is necessary in the design of this aspect of monitoring equipment before it is possible to have a reliable system. ImagesFig. 1 PMID:5476136

  16. Diffusion-weighted imaging and demyelinating diseases: new aspects of an old advanced sequence.

    PubMed

    Rueda-Lopes, Fernanda C; Hygino da Cruz, Luiz C; Doring, Thomas M; Gasparetto, Emerson L

    2014-01-01

    The purpose of this article is to discuss classic applications in diffusion-weighted imaging (DWI) in demyelinating disease and progression of DWI in the near future. DWI is an advanced technique used in the follow-up of demyelinating disease patients, focusing on the diagnosis of a new lesion before contrast enhancement. With technical advances, diffusion-tensor imaging; new postprocessing techniques, such as tract-based spatial statistics; new ways of calculating diffusion, such as kurtosis; and new applications for DWI and its spectrum are about to arise.

  17. Optical Coherence Tomography Updates on Clinical and Technical Developments. Age-Related Macular Degeneration: Drusen and Geographic Atrophy

    NASA Astrophysics Data System (ADS)

    Fleckenstein, Monika; Schmitz-Valckenberg, Steffen; Holz, Frank G.

    Age-related macular degeneration (AMD) is a complex disease with both genetic and environmental factors influencing its development. With the advent of high-resolution OCT imaging, the characterization of drusen in AMD has become possible. The in vivo morphologic characteristics imaged with SD-OCT may represent distinct subclasses of drusen variants, may relate closely to ultrastructural drusen elements identified in donor eyes, and may be useful imaging biomarkers for disease severity or risk of progression [Khanifar et al. Ophthalmology 115(11):1883-1890, 2008].

  18. GEOSTAR-II: A Prototype Water Vapor Imager/Sounder for the Path Mission

    NASA Technical Reports Server (NTRS)

    Gaier, Todd; Lambrigtsen, Bjorn; Kangaslahti, Pekka; Lim, Boon; Tanner, Alan; Harding, Dennis; Owen, Heather; Soria, Mary; ODwyer, Ian; Ruf, Christopher; hide

    2011-01-01

    We describe the development and progress of the GeoSTAR-II risk reduction activity for the NASA Earth Science Decadal Survey PATH Mission. The activity directly addresses areas of technical risk including the system design, low noise receiver production, sub-array development, signal distribution and digital signal processing.

  19. Coherent X-ray diffraction imaging and characterization of strain in silicon-on-insulator nanostructures

    DOE PAGES

    Xiong, Gang; Moutanabbir, Oussama; Reiche, Manfred; ...

    2014-12-06

    Coherent X-ray diffraction imaging (CDI) has emerged in the last decade as a promising high resolution lens-less imaging approach for the characterization of various samples. It has made significant technical progress through developments in source, algorithm and imaging methodologies thus enabling important scientific breakthroughs in a broad range of disciplines. In this report, we will introduce the principles of forward scattering CDI and Bragg geometry CDI (BCDI), with an emphasis on the latter. BCDI exploits the ultra-high sensitivity of the diffraction pattern to the distortions of crystalline lattice. Its ability of imaging strain on the nanometer scale in three dimensionsmore » is highly novel. In this study, we will present the latest progress on the application of BCDI in investigating the strain relaxation behavior in nanoscale patterned strained silicon-on-insulator (sSOI) materials, aiming to understand and engineer strain for the design and implementation of new generation semiconductor devices.« less

  20. Coherent X-ray diffraction imaging and characterization of strain in silicon-on-insulator nanostructures.

    PubMed

    Xiong, Gang; Moutanabbir, Oussama; Reiche, Manfred; Harder, Ross; Robinson, Ian

    2014-12-10

    Coherent X-ray diffraction imaging (CDI) has emerged in the last decade as a promising high resolution lens-less imaging approach for the characterization of various samples. It has made significant technical progress through developments in source, algorithm and imaging methodologies thus enabling important scientific breakthroughs in a broad range of disciplines. In this report, we will introduce the principles of forward scattering CDI and Bragg geometry CDI (BCDI), with an emphasis on the latter. BCDI exploits the ultra-high sensitivity of the diffraction pattern to the distortions of crystalline lattice. Its ability of imaging strain on the nanometer scale in three dimensions is highly novel. We will present the latest progress on the application of BCDI in investigating the strain relaxation behavior in nanoscale patterned strained silicon-on-insulator (sSOI) materials, aiming to understand and engineer strain for the design and implementation of new generation semiconductor devices. © 2014 The Authors. Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Effect of pulsed progressive fluoroscopy on reduction of radiation dose in the cardiac catheterization laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holmes, D.R. Jr.; Wondrow, M.A.; Gray, J.E.

    1990-01-01

    The increased application of therapeutic interventional cardiology procedures is associated with increased radiation exposure to physicians, patients and technical personnel. New advances in imaging techniques have the potential for reducing radiation exposure. A progressive scanning video system with a standard vascular phantom has been shown to decrease entrance radiation exposure. The effect of this system on reducing actual radiation exposure to physicians and technicians was assessed from 1984 through 1987. During this time, progressive fluoroscopy was added sequentially to all four adult catheterization laboratories; no changes in shielding procedures were made. During this time, the case load per physician increasedmore » by 63% and the number of percutaneous transluminal coronary angioplasty procedures (a high radiation procedure) increased by 244%. Despite these increases in both case load and higher radiation procedures, the average radiation exposure per physician declined by 37%. During the same time, the radiation exposure for technicians decreased by 35%. Pulsed progressive fluoroscopy is effective for reducing radiation exposure to catheterization laboratory physicians and technical staff.« less

  2. Technological Innovations in Magnetic Resonance for Early Detection of Cardiovascular Diseases.

    PubMed

    Santarelli, Maria F; Positano, Vincenzo; Martini, Nicola; Valvano, Giuseppe; Landini, Luigi

    2016-01-01

    Most recent technical innovations in cardiovascular MR imaging (CMRI) are presented in this review. They include hardware and software developments, and novelties in parametric mapping. All these recent improvements lead to high spatial and temporal resolution and quantitative information on the heart structure and function. They make it achievable ambitious goals in the field of magnetic resonance, such as the early detection of cardiovascular pathologies. In this review article, we present recent innovations in CMRI, emphasizing the progresses performed and the solutions proposed to some yet opened technical problems.

  3. The linac coherent light source single particle imaging road map

    PubMed Central

    Aquila, A.; Barty, A.; Bostedt, C.; Boutet, S.; Carini, G.; dePonte, D.; Drell, P.; Doniach, S.; Downing, K. H.; Earnest, T.; Elmlund, H.; Elser, V.; Gühr, M.; Hajdu, J.; Hastings, J.; Hau-Riege, S. P.; Huang, Z.; Lattman, E. E.; Maia, F. R. N. C.; Marchesini, S.; Ourmazd, A.; Pellegrini, C.; Santra, R.; Schlichting, I.; Schroer, C.; Spence, J. C. H.; Vartanyants, I. A.; Wakatsuki, S.; Weis, W. I.; Williams, G. J.

    2015-01-01

    Intense femtosecond x-ray pulses from free-electron laser sources allow the imaging of individual particles in a single shot. Early experiments at the Linac Coherent Light Source (LCLS) have led to rapid progress in the field and, so far, coherent diffractive images have been recorded from biological specimens, aerosols, and quantum systems with a few-tens-of-nanometers resolution. In March 2014, LCLS held a workshop to discuss the scientific and technical challenges for reaching the ultimate goal of atomic resolution with single-shot coherent diffractive imaging. This paper summarizes the workshop findings and presents the roadmap toward reaching atomic resolution, 3D imaging at free-electron laser sources. PMID:26798801

  4. The linac coherent light source single particle imaging road map

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aquila, A.; Barty, A.; Bostedt, C.

    Intense femtosecond x-ray pulses from free-electron laser sources allow the imaging of individual particles in a single shot. Early experiments at the Linac Coherent Light Source (LCLS) have led to rapid progress in the field and, so far, coherent diffractive images have been recorded from biological specimens, aerosols, and quantum systems with a few-tens-of-nanometers resolution. In March 2014, LCLS held a workshop to discuss the scientific and technical challenges for reaching the ultimate goal of atomic resolution with single-shot coherent diffractive imaging. This paper summarizes the workshop findings and presents the roadmap toward reaching atomic resolution, 3D imaging at free-electronmore » laser sources.« less

  5. Combined application of imaging techniques for the characterization and authentication of ancient weapons

    NASA Astrophysics Data System (ADS)

    Salvemini, Filomena; Grazzi, Francesco; Kardjilov, Nikolay; Wieder, Frank; Manke, Ingo; Edge, David; Williams, Alan; Zoppi, Marco

    2017-05-01

    Non-invasive experimental methods play an important role in the field of cultural heritage. Benefiting from the technical progress in recent years, neutron imaging has been demonstrated to complement effectively studies based on surface analysis, allowing for a non-invasive characterization of the whole three-dimensional volume. This study focuses on a kris and a kanjar, two weapons from ancient Asia, to show the potential of the combined use of X-ray and neutron imaging techniques for the characterisation of the manufacturing methods and the authentication of objects of cultural and historical interest.

  6. An acoustic charge transport imager for high definition television applications

    NASA Technical Reports Server (NTRS)

    Hunt, W. D.; Brennan, K. F.; Summers, C. J.

    1994-01-01

    The primary goal of this research is to develop a solid-state television (HDTV) imager chip operating at a frame rate of about 170 frames/sec at 2 Megapixels/frame. This imager will offer an order of magnitude improvements in speed over CCD designs and will allow for monolithic imagers operating from the IR to UV. The technical approach of the project focuses on the development of the three basic components of the imager and their subsequent integration. The camera chip can be divided into three distinct functions: (1) image capture via an array of avalanche photodiodes (APD's); (2) charge collection, storage, and overflow control via a charge transfer transistor device (CTD); and (3) charge readout via an array of acoustic charge transport (ACT) channels. The use of APD's allows for front end gain at low noise and low operating voltages while the ACT readout enables concomitant high speed and high charge transfer efficiency. Currently work is progressing towards the optimization of each of these component devices. In addition to the development of each of the three distinct components, work towards their integration and manufacturability is also progressing. The component designs are considered not only to meet individual specifications but to provide overall system level performance suitable for HDTV operation upon integration. The ultimate manufacturability and reliability of the chip constrains the design as well. The progress made during this period is described in detail.

  7. SUSTAINABLE ALLOY DESIGN: SEARCHING FOR RARE EARTH ELEMENT ALTERNATIVES THROUGH CRYSTAL ENGINEERING

    DTIC Science & Technology

    2016-02-26

    Property Maps to Guide Materials Design via Statistical Learning Summer Research Group Meeting – Materials by Design Los Alamos National Laboratory, July...Informatics, Rational design , Quantitative correlative spectroscopy and imaging, DFT, In situ high pressure mechanical property measurements, Superalloy...final, technical, interim, memorandum, master’s thesis, progress, quarterly, research , special, group study, etc. 3. DATES COVERED. Indicate the

  8. Human Systems Center Products and Progress.

    DTIC Science & Technology

    1993-10-01

    and (CASHE:PVS). CASHE:PVS version 1.0 is a CD-ROM- As a precursor to developing collaborative based hypermedia- ergonomic information base design...computer-generated image to determine if the Crew System Ergonomics Information Analysis activity is physically possible. Expert system Center known as...and facility issues relative Federal Drug Administration, and Centers for to dentistry . The scope includes technical Disease Control to establish

  9. DMDs for multi-object near-infrared spectrographs in astronomy

    NASA Astrophysics Data System (ADS)

    Smee, Stephen A.; Barkhouser, Robert; Hope, Stephen; Conley, Devin; Gray, Aidan; Hope, Gavin; Robberto, Massimo

    2018-02-01

    The Digital Micromirror Device (DMD), typically used in projection screen technology, has utility in instrumentation for astronomy as a digitally programmable slit in a spectrograph. When placed at an imaging focal plane the device can be used to selectively direct light from astronomical targets into the optical path of a spectrograph, while at the same time directing the remaining light into an imaging camera, which can be used for slit alignment, science imaging, or both. To date the use of DMDs in astronomy has been limited, especially for instruments that operate in the near infrared (1 - 2.5 μm). This limitation is due in part to a host of technical challenges with respect to DMDs that, to date, have not been thoroughly explored. Those challenges include operation at cryogenic temperature, control electronics that facilitate DMD use at these temperatures, window coatings properly coated for the near infrared bandpass, and scattered light. This paper discusses these technical challenges and presents progress towards understanding and mitigating them.

  10. Printing system perceptual-based gloss and gloss uniformity standard (INCITS W1.1)

    NASA Astrophysics Data System (ADS)

    Ng, Yee S.; Cui, Luke C.; Kuo, Chung-Hui; Maggard, Eric; Mashtare, Dale; Morris, Peter; Viola, Michael

    2003-12-01

    To address the standarization issues of perceptually based image quality for printing systems, ISO/IEC JTC1/SC28, the standarization committee for office equipment charactered the W1.1 project with the responsibiltiy of drafting a proposal for an international standard for the evaluation of printed image quality. One of the W1.1 task teams is charactered to address the issue of 'Gloss and Gloss Uniformity". This paper summarizes the current status and technical progress of this ad hoc team in 2003.

  11. An acoustic charge transport imager for high definition television applications

    NASA Technical Reports Server (NTRS)

    Hunt, W. D.; Brennan, Kevin F.

    1994-01-01

    The primary goal of this research is to develop a solid-state high definition television (HDTV) imager chip operating at a frame rate of about 170 frames/sec at 2 Megapixels per frame. This imager offers an order of magnitude improvement in speed over CCD designs and will allow for monolithic imagers operating from the IR to the UV. The technical approach of the project focuses on the development of the three basic components of the imager and their integration. The imager chip can be divided into three distinct components: (1) image capture via an array of avalanche photodiodes (APD's), (2) charge collection, storage and overflow control via a charge transfer transistor device (CTD), and (3) charge readout via an array of acoustic charge transport (ACT) channels. The use of APD's allows for front end gain at low noise and low operating voltages while the ACT readout enables concomitant high speed and high charge transfer efficiency. Currently work is progressing towards the development of manufacturable designs for each of these component devices. In addition to the development of each of the three distinct components, work towards their integration is also progressing. The component designs are considered not only to meet individual specifications but to provide overall system level performance suitable for HDTV operation upon integration. The ultimate manufacturability and reliability of the chip constrains the design as well. The progress made during this period is described in detail in Sections 2-4.

  12. Mid-IR hyperspectral imaging for label-free histopathology and cytology

    NASA Astrophysics Data System (ADS)

    Hermes, M.; Brandstrup Morrish, R.; Huot, L.; Meng, L.; Junaid, S.; Tomko, J.; Lloyd, G. R.; Masselink, W. T.; Tidemand-Lichtenberg, P.; Pedersen, C.; Palombo, F.; Stone, N.

    2018-02-01

    Mid-infrared (MIR) imaging has emerged as a valuable tool to investigate biological samples, such as tissue histological sections and cell cultures, by providing non-destructive chemical specificity without recourse to labels. While feasibility studies have shown the capabilities of MIR imaging approaches to address key biological and clinical questions, these techniques are still far from being deployable by non-expert users. In this review, we discuss the current state of the art of MIR technologies and give an overview on technical innovations and developments with the potential to make MIR imaging systems more readily available to a larger community. The most promising developments over the last few years are discussed here. They include improvements in MIR light sources with the availability of quantum cascade lasers and supercontinuum IR sources as well as the recently developed upconversion scheme to improve the detection of MIR radiation. These technical advances can substantially speed up data acquisition of multispectral or hyperspectral datasets thus providing the end user with vast amounts of data when imaging whole tissue areas of many mm2. Therefore, effective data analysis is of tremendous importance, and progress in method development is discussed with respect to the specific biomedical context.

  13. Statistical Issues in Testing Conformance with the Quantitative Imaging Biomarker Alliance (QIBA) Profile Claims.

    PubMed

    Obuchowski, Nancy A; Buckler, Andrew; Kinahan, Paul; Chen-Mayer, Heather; Petrick, Nicholas; Barboriak, Daniel P; Bullen, Jennifer; Barnhart, Huiman; Sullivan, Daniel C

    2016-04-01

    A major initiative of the Quantitative Imaging Biomarker Alliance is to develop standards-based documents called "Profiles," which describe one or more technical performance claims for a given imaging modality. The term "actor" denotes any entity (device, software, or person) whose performance must meet certain specifications for the claim to be met. The objective of this paper is to present the statistical issues in testing actors' conformance with the specifications. In particular, we present the general rationale and interpretation of the claims, the minimum requirements for testing whether an actor achieves the performance requirements, the study designs used for testing conformity, and the statistical analysis plan. We use three examples to illustrate the process: apparent diffusion coefficient in solid tumors measured by MRI, change in Perc 15 as a biomarker for the progression of emphysema, and percent change in solid tumor volume by computed tomography as a biomarker for lung cancer progression. Copyright © 2016 The Association of University Radiologists. All rights reserved.

  14. A narrative overview of the current status of MRI of the hip and its relevance for osteoarthritis research - what we know, what has changed and where are we going?

    PubMed

    Crema, M D; Watts, G J; Guermazi, A; Kim, Y-J; Kijowski, R; Roemer, F W

    2017-01-01

    To review and discuss the role of magnetic resonance imaging (MRI) in the context of hip osteoarthritis (OA) research. The content of this narrative review, based on an extensive PubMed database research including English literature only, describes the advances in MRI of the hip joint and its potential usefulness in hip OA research, reviews the relevance of different MRI features in regard to symptomatic and structural progression in hip OA, and gives an outlook regarding future use of MRI in hip OA research endeavors. Recent technical advances have helped to overcome many of the past difficulties related to MRI assessment of hip OA. MRI-based morphologic scoring systems allow for detailed assessment of several hip joint tissues and, in combination with the recent advances in MRI, may increase reproducibility and sensitivity to change. Compositional MRI techniques may add to our understanding of disease onset and progression. Knowledge about imaging pitfalls and anatomical variants is crucial to avoid misinterpretation. In comparison to research on knee OA, the associations between MRI features and the incidence and progression of disease as well as with clinical symptoms have been little explored. Anatomic alterations of the hip joint as seen in femoro-acetabular impingement (FAI) seem to play a role in the onset and progression of structural damage. With the technical advances occurring in recent years, MRI may play a major role in investigating the natural history of hip OA and provide an improved method for assessment of the efficacy of new therapeutic approaches. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  15. Education and career progression of imaging administrators.

    PubMed

    South-Winter, Carole

    2014-01-01

    The advancement into leadership positions for many administrators began as staff technologists moving up via interim management opportunities. New managers must develop supervisory skills while simultaneously assuming responsibility for the operation of the department. Mobility today is based primarily on a formal educational background. A transferable set of skills must be augmented with higher education. Those in the imaging sciences realize that an administrative position requires business and management acumen as well as technical skills. A shortage of imaging administrators is predicted due to an aging population and the rapid advancement of technology in healthcare. Institutes of higher education need to address and support the curricula and programs needed, which includes the CRA credential, for this growing field.

  16. 48 CFR 742.1170-4 - Progress reporting requirements and contract clause.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... progress. (b) Because the cognizant technical officer is the individual most familiar with the contractor's performance, the contractor must submit the progress reports directly to the cognizant technical officer. The cognizant technical officer must review the reports and advise the contracting officer, in writing, of any...

  17. Education, Technical Progress, and Economic Growth: The Case of Taiwan.

    ERIC Educational Resources Information Center

    Lin, T.-C.

    2003-01-01

    Investigates the effect of education and the role of technical progress on economic growth in Taiwan from 1965-2000. Finds that education has a positive and significant effect on growth, but the role of technical progress does not appear to be extraordinarily important. Furthermore, no markedly significant relationships exist between capital and…

  18. A new semiquantitative method for evaluation of metastasis progression.

    PubMed

    Volarevic, A; Ljujic, B; Volarevic, V; Milovanovic, M; Kanjevac, T; Lukic, A; Arsenijevic, N

    2012-01-01

    Although recent technical advancements are directed toward developing novel assays and methods for detection of micro and macro metastasis, there are still no reports of reliable, simple to use imaging software that could be used for the detection and quantification of metastasis in tissue sections. We herein report a new semiquantitative method for evaluation of metastasis progression in a well established 4T1 orthotopic mouse model of breast cancer metastasis. The new semiquantitative method presented here was implemented by using the Autodesk AutoCAD 2012 program, a computer-aided design program used primarily for preparing technical drawings in 2 dimensions. By using the Autodesk AutoCAD 2012 software- aided graphical evaluation we managed to detect each metastatic lesion and we precisely calculated the average percentage of lung and liver tissue parenchyma with metastasis in 4T1 tumor-bearing mice. The data were highly specific and relevant to descriptive histological analysis, confirming reliability and accuracy of the AutoCAD 2012 software as new method for quantification of metastatic lesions. The new semiquantitative method using AutoCAD 2012 software provides a novel approach for the estimation of metastatic progression in histological tissue sections.

  19. Adaptive optics ophthalmoscopy: results and applications.

    PubMed

    Pallikaris, A

    2005-01-01

    The living human eye's optical aberrations set a limit to retinal imaging in the clinical setting. Progress in the field of adaptive optics has offered unique solutions to this problem. The purpose of this review is to summarize the most recent advances in adaptive optics ophthalmoscopy. Adaptive optics technology has been combined with flood illumination imaging, confocal scanning laser ophthalmoscopy, and optical coherence tomography for the high resolution imaging of the retina. The advent of adaptive optics technology has provided the technical platform for the compensation of the eye's aberration and made possible the observation of single cones, small capillaries, nerve fibers, and leukocyte dynamics as well as the ultrastructure of the optic nerve head lamina cribrosa in vivo. Detailed imaging of retinal infrastructure provides valuable information for the study of retinal physiology and pathology.

  20. Webinar May 17: Fuel Cell Electric Bus Progress Toward Meeting Technical

    Science.gov Websites

    Targets | News | NREL Webinar May 17: Fuel Cell Electric Bus Progress toward Meeting Technical Targets Webinar May 17: Fuel Cell Electric Bus Progress toward Meeting Technical Targets May 14, 2018 The U.S. Department of Energy's (DOE's) Fuel Cell Technologies Office will present a live webinar titled

  1. [3D imaging benefits in clinical pratice of orthodontics].

    PubMed

    Frèrejouand, Emmanuel

    2016-12-01

    3D imaging possibilities raised up in the last few years in the orthodontic field. In 2016, it can be used for diagnosis improvement and treatment planning by using digital set up combined to CBCT. It is relevant for orthodontic mechanic updating by creating visible or invisible customised appliances. It forms the basis of numerous scientific researches. The author explains the progress 3D imaging brings to diagnosis and clinics but also highlights the requirements it creates. The daily use of these processes in orthodontic clinical practices needs to be regulated regarding the benefit/risk ratio and the patient satisfaction. The command of the digital work flow created by these technics requires habits modifications from the orthodontist and his staff. © EDP Sciences, SFODF, 2016.

  2. 25 CFR 30.111 - When should the tribal governing body or school board request technical assistance?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... request technical assistance? 30.111 Section 30.111 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR EDUCATION ADEQUATE YEARLY PROGRESS Defining Adequate Yearly Progress Technical Assistance § 30.111 When should the tribal governing body or school board request technical assistance? In order to...

  3. Contrast Media for X-ray and Magnetic Resonance Imaging: Development, Current Status and Future Perspectives.

    PubMed

    Frenzel, Thomas; Lawaczeck, Rüdiger; Taupitz, Matthias; Jost, Gregor; Lohrke, Jessica; Sieber, Martin A; Pietsch, Hubertus

    2015-09-01

    Over the last 120 years, the extensive advances in medical imaging allowed enhanced diagnosis and therapy of many diseases and thereby improved the quality of life of many patient generations. From the beginning, all technical solutions and imaging procedures were combined with dedicated pharmaceutical developments of contrast media, to further enhance the visualization of morphology and physiology. This symbiosis of imaging hardware and contrast media development was of high importance for the development of modern clinical radiology. Today, all available clinically approved contrast media fulfill the highest requirements for clinical safety and efficacy. All new concepts to increase the efficacy of contrast media have also to consider the high clinical safety standards and cost of goods of current marketed contrast media. Nevertheless, diagnostic imaging will contribute significantly to the progresses in medicine, and new contrast media developments are mandatory to address the medical needs of the future.

  4. 25 CFR 30.110 - What is the process for requesting technical assistance to develop an alternative definition of AYP?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., DEPARTMENT OF THE INTERIOR EDUCATION ADEQUATE YEARLY PROGRESS Defining Adequate Yearly Progress Technical Assistance § 30.110 What is the process for requesting technical assistance to develop an alternative... 25 Indians 1 2011-04-01 2011-04-01 false What is the process for requesting technical assistance...

  5. 25 CFR 30.110 - What is the process for requesting technical assistance to develop an alternative definition of AYP?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false What is the process for requesting technical assistance..., DEPARTMENT OF THE INTERIOR EDUCATION ADEQUATE YEARLY PROGRESS Defining Adequate Yearly Progress Technical Assistance § 30.110 What is the process for requesting technical assistance to develop an alternative...

  6. Image Transmission via Spread Spectrum Techniques. Part A

    DTIC Science & Technology

    1976-01-01

    Code 408 DR. EDWIN H. WRENCH (714-225-6871) Code 408 and HARPER J. WHITEHOUSE (714:225-6315), Code 4002 Naval Undersea Center San Diego. California...progress report appears in two parts. Part A is a summary of work done in support of this program at the Naval Undersea Center. Part B contains final...a technical description of the bandwidth compression system developed at the Naval Undersea Center. This paper is an excerpt from the specifications

  7. Technical flaws in multiple-choice questions in the access exam to medical specialties ("examen MIR") in Spain (2009-2013).

    PubMed

    Rodríguez-Díez, María Cristina; Alegre, Manuel; Díez, Nieves; Arbea, Leire; Ferrer, Marta

    2016-02-03

    The main factor that determines the selection of a medical specialty in Spain after obtaining a medical degree is the MIR ("médico interno residente", internal medical resident) exam. This exam consists of 235 multiple-choice questions with five options, some of which include images provided in a separate booklet. The aim of this study was to analyze the technical quality of the multiple-choice questions included in the MIR exam over the last five years. All the questions included in the exams from 2009 to 2013 were analyzed. We studied the proportion of questions including clinical vignettes, the number of items related to an image and the presence of technical flaws in the questions. For the analysis of technical flaws, we adapted the National Board of Medical Examiners (NBME) guidelines. We looked for 18 different issues included in the manual, grouped into two categories: issues related to testwiseness and issues related to irrelevant difficulties. The final number of questions analyzed was 1,143. The percentage of items based on clinical vignettes increased from 50% in 2009 to 56-58% in the following years (2010-2013). The percentage of items based on an image increased progressively from 10% in 2009 to 15% in 2012 and 2013. The percentage of items with at least one technical flaw varied between 68 and 72%. We observed a decrease in the percentage of items with flaws related to testwiseness, from 30% in 2009 to 20% in 2012 and 2013. While most of these issues decreased dramatically or even disappeared (such as the imbalance in the correct option numbers), the presence of non-plausible options remained frequent. With regard to technical flaws related to irrelevant difficulties, no improvement was observed; this is especially true with respect to negative stem questions and "hinged" questions. The formal quality of the MIR exam items has improved over the last five years with regard to testwiseness. A more detailed revision of the items submitted, checking systematically for the presence of technical flaws, could improve the validity and discriminatory power of the exam, without increasing its difficulty.

  8. 14 CFR 1274.701 - Suspension or termination.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Agreement if the recipient is not making anticipated technical progress, if the recipient materially changes...) Similarly, the recipient may terminate the agreement if, for example, technical progress is not being made, if the commercial recipient shifts its technical emphasis, or if other technological advances have...

  9. 14 CFR 1274.701 - Suspension or termination.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Agreement if the recipient is not making anticipated technical progress, if the recipient materially changes...) Similarly, the recipient may terminate the agreement if, for example, technical progress is not being made, if the commercial recipient shifts its technical emphasis, or if other technological advances have...

  10. Real-time magnetic resonance imaging of cardiac function and flow—recent progress

    PubMed Central

    Zhang, Shuo; Joseph, Arun A.; Voit, Dirk; Schaetz, Sebastian; Merboldt, Klaus-Dietmar; Unterberg-Buchwald, Christina; Hennemuth, Anja; Lotz, Joachim

    2014-01-01

    Cardiac structure, function and flow are most commonly studied by ultrasound, X-ray and magnetic resonance imaging (MRI) techniques. However, cardiovascular MRI is hitherto limited to electrocardiogram (ECG)-synchronized acquisitions and therefore often results in compromised quality for patients with arrhythmias or inabilities to comply with requested protocols—especially with breath-holding. Recent advances in the development of novel real-time MRI techniques now offer dynamic imaging of the heart and major vessels with high spatial and temporal resolution, so that examinations may be performed without the need for ECG synchronization and during free breathing. This article provides an overview of technical achievements, physiological validations, preliminary patient studies and translational aspects for a future clinical scenario of cardiovascular MRI in real time. PMID:25392819

  11. Progress in Scientific and Technical Communications, 1968 Annual Report.

    ERIC Educational Resources Information Center

    Federal Council for Science and Technology, Washington, DC. Committee on Scientific and Technical Information.

    This sixth annual report describes progress achieved by the Federal Government in improving the communication of scientific and technical information to support and enhance national science and technology. Included in the report are details regarding the scientific and technical activities of individual Federal Agencies, such as the Atomic Energy…

  12. Applications of nanopipettes in bionanotechnology.

    PubMed

    Ying, Liming

    2009-08-01

    At present, technical hurdles remain in probing biochemical processes in living cells and organisms at nanometre spatial resolution, millisecond time resolution and with high specificity and single-molecule sensitivity. Owing to its unique shape, size and electrical properties, the nanopipette has been used to obtain high-resolution topographic images of live cells under physiological conditions, and to create nanoscale features by controlled delivery of biomolecules. In the present paper, I discuss recent progress in the development of a family of new methods for nanosensing and nanomanipulation using nanopipettes.

  13. W(h)ither human cardiac and body magnetic resonance at ultrahigh fields? technical advances, practical considerations, applications, and clinical opportunities.

    PubMed

    Niendorf, Thoralf; Paul, Katharina; Oezerdem, Celal; Graessl, Andreas; Klix, Sabrina; Huelnhagen, Till; Hezel, Fabian; Rieger, Jan; Waiczies, Helmar; Frahm, Jens; Nagel, Armin M; Oberacker, Eva; Winter, Lukas

    2016-09-01

    The objective of this study was to document and review advances and groundbreaking progress in cardiac and body MR at ultrahigh fields (UHF, B0 ≥ 7.0 T) with the goal to attract talent, clinical adopters, collaborations and resources to the biomedical and diagnostic imaging communities. This review surveys traits, advantages and challenges of cardiac and body MR at 7.0 T. The considerations run the gamut from technical advances to clinical opportunities. Key concepts, emerging technologies, practical considerations, frontier applications and future directions of UHF body and cardiac MR are provided. Examples of UHF cardiac and body imaging strategies are demonstrated. Their added value over the kindred counterparts at lower fields is explored along with an outline of research promises. The achievements of cardiac and body UHF-MR are powerful motivators and enablers, since extra speed, signal and imaging capabilities may be invested to overcome the fundamental constraints that continue to hamper traditional cardiac and body MR applications. If practical obstacles, concomitant physics effects and technical impediments can be overcome in equal measure, sophisticated cardiac and body UHF-MR will help to open the door to new MRI and MRS approaches for basic research and clinical science, with the lessons learned at 7.0 T being transferred into broad clinical use including diagnostics and therapy guiding at lower fields. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  14. The Quickest, Lowest-cost Lunar Resource Assessment Program: Integrated High-tech Earth-based Astronomy

    NASA Technical Reports Server (NTRS)

    Pieters, Carle M.

    1992-01-01

    Science and technology applications for the Moon have not fully kept pace with technical advancements in sensor development and analytical information extraction capabilities. Appropriate unanswered questions for the Moon abound, but until recently there has been little motivation to link sophisticated technical capabilities with specific measurement and analysis projects. Over the last decade enormous technical progress has been made in the development of (1) CCD photometric array detectors; (2) visible to near-infrared imaging spectrometers; (3)infrared spectroscopy; (4) high-resolution dual-polarization radar imaging at 3.5, 12, and 70 cm; and equally important (5) data analysis and information extraction techniques using compact powerful computers. Parts of each of these have been tested separately, but there has been no programmatic effort to develop and optimize instruments to meet lunar science and resource assessment needs (e.g., specific wavelength range, resolution, etc.) nor to coordinate activities so that the symbiotic relation between different kinds of data can be fully realized. No single type of remotely acquired data completely characterizes the lunar environment, but there has been little opportunity for integration of diverse advanced sensor data for the Moon. Two examples of technology concepts for lunar measurements are given. Using VIS/near-IR spectroscopy, the mineral composition of surface material can be derived from visible and near-infrared radiation reflected from the surface. The surface and subsurface scattering properties of the Moon can be analyzed using radar backscattering imaging.

  15. 48 CFR 2452.242-71 - Contract management system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., concise summary of technical progress made and the costs incurred for each task during the reporting... technical progress made for each task during the reporting period; and (B) Identifies problems, or potential... and progress reporting as described herein. (b) The contract management system shall consist of two...

  16. Progress in video immersion using Panospheric imaging

    NASA Astrophysics Data System (ADS)

    Bogner, Stephen L.; Southwell, David T.; Penzes, Steven G.; Brosinsky, Chris A.; Anderson, Ron; Hanna, Doug M.

    1998-09-01

    Having demonstrated significant technical and marketplace advantages over other modalities for video immersion, PanosphericTM Imaging (PI) continues to evolve rapidly. This paper reports on progress achieved since AeroSense 97. The first practical field deployment of the technology occurred in June-August 1997 during the NASA-CMU 'Atacama Desert Trek' activity, where the Nomad mobile robot was teleoperated via immersive PanosphericTM imagery from a distance of several thousand kilometers. Research using teleoperated vehicles at DRES has also verified the exceptional utility of the PI technology for achieving high levels of situational awareness, operator confidence, and mission effectiveness. Important performance enhancements have been achieved with the completion of the 4th Generation PI DSP-based array processor system. The system is now able to provide dynamic full video-rate generation of spatial and computational transformations, resulting in a programmable and fully interactive immersive video telepresence. A new multi- CCD camera architecture has been created to exploit the bandwidth of this processor, yielding a well-matched PI system with greatly improved resolution. While the initial commercial application for this technology is expected to be video tele- conferencing, it also appears to have excellent potential for application in the 'Immersive Cockpit' concept. Additional progress is reported in the areas of Long Wave Infrared PI Imaging, Stereo PI concepts, PI based Video-Servoing concepts, PI based Video Navigation concepts, and Foveation concepts (to merge localized high-resolution views with immersive views).

  17. Clinical Neuropathology Views - 2/2016: Digital networking in European neuropathology: An initiative to facilitate truly interactive consultations.

    PubMed

    Idoate, Miguel A; García-Rojo, Marcial

    2016-01-01

    Digital technology is progressively changing our vision of the practice of neuropathology. There are a number of facts that support the introduction of digital neuropathology. With the development of wholeslide imaging (WSI) systems the difficulties involved in implementing a neuropathology network have been solved. A relevant difficulty has been image standardization, but an open digital image communication protocol defined by the Digital Imaging and Communications in Medicine (DICOM) standard is already a reality. The neuropathology network should be established in Europe because it is the expected geographic context for relationships among European neuropathologists. There are several limitations in the implementation of a digital neuropathology consultancy network such as financial support, operational costs, legal issues, and technical assistance of clients. All of these items have been considered and should be solved before implementing the proposal. Finally, the authors conclude that a European digital neuropathology network should be created for patients' benefit.

  18. ANNUAL REPORT, JULY 1, 1957

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1958-10-31

    The progress and trends of research are presented along with a description of operational, service, end administrative activities. Some scientific and technical details are given on research programs in the physical sciences, life sciences, and engineering, however, more complete technical information is available in quarterly progress reports, BNL technical reports, and scientific and technical periodicals. A bibliography of these publications is appended. (For preceding period see BNL-426.) (D.E.B.)

  19. 20 CFR 411.180 - What is timely progress toward self-supporting employment?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... certificate or vocational or technical training that will enhance your ability to return to work. In addition...-secondary education requirement or vocational or technical training requirement in the applicable progress... this 12-month period; or (iv) You must have been enrolled in a vocational or technical training program...

  20. Comparison of fluorescence probes for intracellular sodium imaging in prostate cancer cell lines.

    PubMed

    Iamshanova, Oksana; Mariot, Pascal; Lehen'kyi, V'yacheslav; Prevarskaya, Natalia

    2016-10-01

    Sodium (Na + ) ions are known to regulate many signaling pathways involved in both physiological and pathological conditions. In particular, alterations in intracellular concentrations of Na + and corresponding changes in membrane potential are known to be major actors of cancer progression to metastatic phenotype. Though the functionality of Na + channels and the corresponding Na + currents can be investigated using the patch-clamp technique, the latter is rather invasive and a technically difficult method to study intracellular Na + transients compared to Na + fluorescence imaging. Despite the fact that Na + signaling is considered an important controller of cancer progression, only few data using Na + imaging approaches are available so far, suggesting the persisting challenge within the scientific community. In this study, we describe in detail the approach for application of Na + imaging technique to measure intracellular Na + variations in human prostate cancer cells. Accordingly, we used three Na + -specific fluorescent dyes-Na + -binding benzofuran isophthalate (SBFI), CoroNa™ Green (Corona) and Asante NaTRIUM Green-2 (ANG-2). These dyes have been assessed for optimal loading conditions, dissociation constant and working range after different calibration methods, and intracellular Na + sensitivity, in order to determine which probe can be considered as the most reliable to visualize Na + fluctuations in vitro.

  1. Digital information management: a progress report on the National Digital Mammography Archive

    NASA Astrophysics Data System (ADS)

    Beckerman, Barbara G.; Schnall, Mitchell D.

    2002-05-01

    Digital mammography creates very large images, which require new approaches to storage, retrieval, management, and security. The National Digital Mammography Archive (NDMA) project, funded by the National Library of Medicine (NLM), is developing a limited testbed that demonstrates the feasibility of a national breast imaging archive, with access to prior exams; patient information; computer aids for image processing, teaching, and testing tools; and security components to ensure confidentiality of patient information. There will be significant benefits to patients and clinicians in terms of accessible data with which to make a diagnosis and to researchers performing studies on breast cancer. Mammography was chosen for the project, because standards were already available for digital images, report formats, and structures. New standards have been created for communications protocols between devices, front- end portal and archive. NDMA is a distributed computing concept that provides for sharing and access across corporate entities. Privacy, auditing, and patient consent are all integrated into the system. Five sites, Universities of Pennsylvania, Chicago, North Carolina and Toronto, and BWXT Y12, are connected through high-speed networks to demonstrate functionality. We will review progress, including technical challenges, innovative research and development activities, standards and protocols being implemented, and potential benefits to healthcare systems.

  2. Blood oxygenation level-dependent MRI for assessment of renal oxygenation

    PubMed Central

    Neugarten, Joel; Golestaneh, Ladan

    2014-01-01

    Blood oxygen level-dependent magnetic resonance imaging (BOLD MRI) has recently emerged as an important noninvasive technique to assess intrarenal oxygenation under physiologic and pathophysiologic conditions. Although this tool represents a major addition to our armamentarium of methodologies to investigate the role of hypoxia in the pathogenesis of acute kidney injury and progressive chronic kidney disease, numerous technical limitations confound interpretation of data derived from this approach. BOLD MRI has been utilized to assess intrarenal oxygenation in numerous experimental models of kidney disease and in human subjects with diabetic and nondiabetic chronic kidney disease, acute kidney injury, renal allograft rejection, contrast-associated nephropathy, and obstructive uropathy. However, confidence in conclusions based on data derived from BOLD MRI measurements will require continuing advances and technical refinements in the use of this technique. PMID:25473304

  3. DNA nanomapping using CRISPR-Cas9 as a programmable nanoparticle.

    PubMed

    Mikheikin, Andrey; Olsen, Anita; Leslie, Kevin; Russell-Pavier, Freddie; Yacoot, Andrew; Picco, Loren; Payton, Oliver; Toor, Amir; Chesney, Alden; Gimzewski, James K; Mishra, Bud; Reed, Jason

    2017-11-21

    Progress in whole-genome sequencing using short-read (e.g., <150 bp), next-generation sequencing technologies has reinvigorated interest in high-resolution physical mapping to fill technical gaps that are not well addressed by sequencing. Here, we report two technical advances in DNA nanotechnology and single-molecule genomics: (1) we describe a labeling technique (CRISPR-Cas9 nanoparticles) for high-speed AFM-based physical mapping of DNA and (2) the first successful demonstration of using DVD optics to image DNA molecules with high-speed AFM. As a proof of principle, we used this new "nanomapping" method to detect and map precisely BCL2-IGH translocations present in lymph node biopsies of follicular lymphoma patents. This HS-AFM "nanomapping" technique can be complementary to both sequencing and other physical mapping approaches.

  4. [Low-field magnetic resonance imaging for rheumatoid arthritis].

    PubMed

    Ostendorf, B; Edelmann, E; Kellner, H; Scherer, A

    2010-02-01

    Magnetic resonance imaging (MRI) as a cross-sectional imaging procedure allows a three-dimensional representation of musculature, ligaments, tendons, capsules, synovial membranes, bones and cartilage with high resolution quality. An activity assessment is further possible by application of a contrast medium (gadolinium-DTPA) to differentiate between active and chronic inflammatory processes. Evidence of a bone marrow edema detected by MRI in patients with rheumatoid arthritis (RA) can be interpreted as a prognostic and predictive factor for the development of bone erosions. On the basis of these advantages MRI is being employed more and more in the early diagnosis of inflammatory joint diseases. Semi-quantitative scores for analysis and grading of findings have already been developed and are in clinical use. Because MRI technical performances are invariably reproducible they can be practically retrieved in the course of examination which is particularly relevant in rheumatology. Therapy response or progression can thus be adequately displayed. Open, dedicated low-field MRI with a low signal strength of 0.2 Tesla (T) has been known since the 90s and now represents new MRI examination options in rheumatology. Smaller devices with lower acquisition and maintenance expenses as well as considerably more convenience due to the device itself result in a higher subjective acceptability by the patients as well as objectively more data records of low-field MRI scans of RA, which underline the significance of this new technical method. The German Society for Rheumatology (DGRh), represented by the Committee for "Diagnostic Imaging", meets this development with the release of recommendations and standards for the procedures of low-field MRI and their scoring and summarizes the most important technical data and information on clinical indications.

  5. Instrumentation progress at the Giant Magellan Telescope project

    NASA Astrophysics Data System (ADS)

    Jacoby, George H.; Bernstein, R.; Bouchez, A.; Colless, M.; Crane, Jeff; DePoy, D.; Espeland, B.; Hare, Tyson; Jaffe, D.; Lawrence, J.; Marshall, J.; McGregor, P.; Shectman, Stephen; Sharp, R.; Szentgyorgyi, A.; Uomoto, Alan; Walls, B.

    2016-08-01

    Instrument development for the 24m Giant Magellan Telescope (GMT) is described: current activities, progress, status, and schedule. One instrument team has completed its preliminary design and is currently beginning its final design (GCLEF, an optical 350-950 nm, high-resolution and precision radial velocity echelle spectrograph). A second instrument team is in its conceptual design phase (GMACS, an optical 350-950 nm, medium resolution, 6-10 arcmin field, multi-object spectrograph). A third instrument team is midway through its preliminary design phase (GMTIFS, a near-IR YJHK diffraction-limited imager/integral-field-spectrograph), focused on risk reduction prototyping and design optimization. A fourth instrument team is currently fabricating the 5 silicon immersion gratings needed to begin its preliminary design phase (GMTNIRS, a simultaneous JHKLM high-resolution, AO-fed, echelle spectrograph). And, another instrument team is focusing on technical development and prototyping (MANIFEST, a facility robotic, multifiber feed, with a 20 arcmin field of view). In addition, a medium-field (6 arcmin, 0.06 arcsec/pix) optical imager will support telescope and AO commissioning activities, and will excel at narrow-band imaging. In the spirit of advancing synergies with other groups, the challenges of running an ELT instrument program and opportunities for cross-ELT collaborations are discussed.

  6. Current status of x-ray mask manufacturing at the Microlithographic Mask Development Center

    NASA Astrophysics Data System (ADS)

    Kimmel, Kurt R.; Hughes, Patrick J.

    1996-07-01

    The Microlithographic Mask Development Center (MMD) has been the focal point of X-ray mask development efforts in the United States since its inception in 1993. Funded by the Advanced Research Projects Agency (ARPA), and with technical support from the Proximity X-ray Lithography Association (AT&T, IBM, Loral Federal Systems, and Motorola) the MMD has recently made dramatic advances in mask fabrication. Numerous defect-free 64Mb and 256Mb DRAM masks have been made on both boron-doped silicon and silicon carbide substrates. Image-placement error of less than 35nm 3 sigma is achieved with high yield. Image-size (critical dimension) control of 25nm 3 sigma on 250nm nominal images is representative performance. This progress is being made in a manufacturing environment with significant volumes, multiple customers, multiple substrate configurations, and fast turnaround-time (TAT) requirements. The MMD state-of-the-art equipment infrastructure has made much of this progress possible. This year the MMD qualified the EL-4, an IBM-designed-and-built variable-shaped-spot e-beam system. The fundamental performance parameters of this system will be described. Operational techniques of multiple partial exposure writing and product specific emulation (PSE) have been implemented to improve image-placement accuracy with remarkable success. Image-size control was studied in detail with contributory components separated. Defect density was systematically reduced to yield defect-free masks while simultaneously tightening inspection criteria. Information about these and other recent engineering highlights will be reported. An outline of the primary engineering challenges and goals for 1996 and status of progress toward 100 nm design rule capability will also be given.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluationmore » of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have selected the key areas which demand awareness and attention in order to make SPECT operational in clinical practice. These include selection of equipment, details of uniformity correction, utilization of phantoms for equipment acceptance and quality assurance, the major aspect of algorithms, an understanding of filtered back projection and appropriate choice of filters and an awareness of the most commonly generated artifacts and how to recognize them. With respect to the acquisition and interpretation of organ images, the faculty will present information on the major aspects of hepatic, brain, cardiac, skeletal, and immunologic imaging techniques. Individual papers are processed separately for the data base. (TEM)« less

  8. Evaporation by mechanical vapor recompression. Technical progress report, September 1-December 31, 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iverson, C.H.; Coury, G.E.

    1979-01-01

    Progress to date in the development of a study of the application of the technologies of mechanical vapor recompression and falling film evaporators as applied to the beet sugar industry is reported. Progress is reported in the following areas: technical literature search and plant visitations of existing applications of VR/FFE.

  9. 25 CFR 30.109 - Will the Secretary provide assistance in developing an alternative AYP definition?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... EDUCATION ADEQUATE YEARLY PROGRESS Defining Adequate Yearly Progress Technical Assistance § 30.109 Will the... Bureau, shall provide technical assistance either directly or through contract to the tribal governing...

  10. 25 CFR 30.109 - Will the Secretary provide assistance in developing an alternative AYP definition?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... EDUCATION ADEQUATE YEARLY PROGRESS Defining Adequate Yearly Progress Technical Assistance § 30.109 Will the... Bureau, shall provide technical assistance either directly or through contract to the tribal governing...

  11. Intraoperative Magnetic Resonance Imaging-Guided Biopsy in the Diagnosis of Suprasellar Langerhans Cell Histiocytosis.

    PubMed

    Carroll, Kate T; Lochte, Bryson C; Chen, James Y; Snyder, Vivian S; Carter, Bob S; Chen, Clark C

    2018-04-01

    Magnetic resonance imaging (MRI)-guided biopsy is an emerging diagnostic technique that holds great promise for otherwise difficult to access neuroanatomy. Here we describe MRI-guided biopsy of a suprasellar lesion located posterior and superior to the pituitary stalk. The approach was implemented successfully in a 38-year-old woman who had developed progressive visual deterioration. Intraoperative MRI revealed the need for trajectory adjustment due to an unintended, minor deviation in the burr hole entry point, demonstrating the benefit of an MRI-guided approach. Langerhans cell histiocytosis was diagnosed after biopsy, and the lesion regressed after cladribine treatment. Technical nuances of the case are reviewed in the context of the available literature. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Magnetic resonance-compatible robotic and mechatronics systems for image-guided interventions and rehabilitation: a review study.

    PubMed

    Tsekos, Nikolaos V; Khanicheh, Azadeh; Christoforou, Eftychios; Mavroidis, Constantinos

    2007-01-01

    The continuous technological progress of magnetic resonance imaging (MRI), as well as its widespread clinical use as a highly sensitive tool in diagnostics and advanced brain research, has brought a high demand for the development of magnetic resonance (MR)-compatible robotic/mechatronic systems. Revolutionary robots guided by real-time three-dimensional (3-D)-MRI allow reliable and precise minimally invasive interventions with relatively short recovery times. Dedicated robotic interfaces used in conjunction with fMRI allow neuroscientists to investigate the brain mechanisms of manipulation and motor learning, as well as to improve rehabilitation therapies. This paper gives an overview of the motivation, advantages, technical challenges, and existing prototypes for MR-compatible robotic/mechatronic devices.

  13. Radioisotopes for research on and control of mosquitos

    PubMed Central

    Bruce-Chwatt, Leonard J.

    1956-01-01

    Practical applications of radioactive isotopes in medicine, science, and industry have multiplied enormously during the past five years. In this paper, the author attempts to gather what is known about the use of radioactive isotopes in the research on malaria control. The development of the uranium pile for large-scale production of radioisotopes and technical progress in the making of reliable electronic equipment have greatly contributed to the application of radioactive tracers in biological research. The present knowledge of radioisotopes in mosquito and in insecticide research is discussed. ImagesFIG. 1 PMID:13404435

  14. Monitoring the Durability Performance of Concrete in Nuclear Waste Containment. Technical Progress Report No. 3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ulm, Franz-Josef

    2000-03-31

    OAK-B135 Monitoring the Durability Performance of Concrete in Nuclear Waste Containment. Technical Progress Report No. 3(NOTE: Part II A item 1 indicates ''PAPER'', but a report is attached electronically)

  15. Crosscutting Technology Development at the Center for Advanced Separation Technologies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christopher E. Hull

    2006-09-30

    This Technical Progress Report describes progress made on the twenty nine subprojects awarded in the second year of Cooperative Agreement DE-FC26-02NT41607: Crosscutting Technology Development at the Center for Advanced Separation Technologies. This work is summarized in the body of the main report: the individual sub-project Technical Progress Reports are attached as Appendices.

  16. CROSSCUTTING TECHNOLOGY DEVELOPMENT AT THE CENTER FOR ADVANCED SEPARATION TECHNOLOGIES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christopher E. Hull

    2006-05-15

    This Technical Progress Report describes progress made on the twenty nine subprojects awarded in the second year of Cooperative Agreement DE-FC26-02NT41607: Crosscutting Technology Development at the Center for Advanced Separation Technologies. This work is summarized in the body of the main report: the individual sub-project Technical Progress Reports are attached as Appendices.

  17. The Development and Technical Adequacy of Seventh-Grade Reading Comprehension Measures in a Progress Monitoring Assessment System. Technical Report #1102

    ERIC Educational Resources Information Center

    Park, Bitnara Jasmine; Alonzo, Julie; Tindal, Gerald

    2011-01-01

    This technical report describes the process of development and piloting of reading comprehension measures that are appropriate for seventh-grade students as part of an online progress screening and monitoring assessment system, http://easycbm.com. Each measure consists of an original fictional story of approximately 1,600 to 1,900 words with 20…

  18. Generation and focusing of pulsed intense ion beams. Technical progress report, 1 October 1982 - 30 September, 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hammer, D.A.; Kusse, B.R.; Sudan, R.N.

    1983-07-01

    The progress on this contract is described in three parts. The first deals with the technical operation of the LION accelerator. The second and third parts are concerned with the experimental results.

  19. Liver CT image processing: a short introduction of the technical elements.

    PubMed

    Masutani, Y; Uozumi, K; Akahane, Masaaki; Ohtomo, Kuni

    2006-05-01

    In this paper, we describe the technical aspects of image analysis for liver diagnosis and treatment, including the state-of-the-art of liver image analysis and its applications. After discussion on modalities for liver image analysis, various technical elements for liver image analysis such as registration, segmentation, modeling, and computer-assisted detection are covered with examples performed with clinical data sets. Perspective in the imaging technologies is also reviewed and discussed.

  20. Progress in digestive endoscopy: Flexible Spectral Imaging Colour Enhancement (FICE)-technical review.

    PubMed

    Negreanu, L; Preda, C M; Ionescu, D; Ferechide, D

    2015-01-01

    Background. A substantial advance in digestive endoscopy that has been made during the last decade is represented by digital chromoendoscopy, which was developed as a quicker and sometimes better alternative to the gold standard of dye spraying. Fujifilm developed a virtual coloration technique called Flexible spectral Imaging Color Enhancement (FICE). FICE provides a better detection of lesions of "minimal" esophagitis, of dysplasia in Barrett's esophagus and of squamous cell esophageal cancer. The use of FICE resulted in an improvement in the visualization of the early gastric cancer, being less invasive, and time consuming than the classic dye methods. Current evidence does not support FICE for screening purposes in colon cancer but it definitely improves characterization of colonic lesions. Its use in inflammatory bowel disease is still controversial and in video capsule endoscopy is considered a substantial progress. Conclusions. The use of FICE endoscopy in routine clinical practice can increase the diagnostic yield and can provide a better characterization of lesions. Future studies to validate its use, the good choice of channels, and the "perfect indications" and to provide common definitions and classifications are necessary.

  1. The Development of K-8 Progress Monitoring Measures in Mathematics for Use with the 2% and General Education Populations: Kindergarten. Technical Report # 0921

    ERIC Educational Resources Information Center

    Alonzo, Julie; Tindal, Gerald

    2009-01-01

    In this technical report, we describe the development and piloting of a series of mathematics progress monitoring measures intended for use with students in kindergarten. These measures, available as part of easyCBM[TM], an online progress monitoring assessment system, were developed in 2008 and administered to approximately 2800 students from…

  2. Assessment Program Technical Progress Report, 1996-1997.

    ERIC Educational Resources Information Center

    McCown, Laurie; Fanning, Erin; Eickmeyer, Barbara

    Coconino Community College (CCC) annually assesses its institutional effectiveness to demonstrate its commitment to improving programs and services to students. The 1996-97 Assessment Program Technical Progress Report records the assessment and institutional activities enacted during the academic year, detailing the assessment model, timelines,…

  3. The Development of K-8 Progress Monitoring Measures in Mathematics for Use with the 2% and General Education Populations: Grade 1. Technical Report # 0919

    ERIC Educational Resources Information Center

    Alonzo, Julie; Tindal, Gerald

    2009-01-01

    In this technical report, we describe the development and piloting of a series of mathematics progress monitoring measures intended for use with students in grade 1. These measures, available as part of easyCBM [TM], an online progress monitoring assessment system, were developed in 2008 and administered to approximately 2800 students from schools…

  4. The Development of K-8 Progress Monitoring Measures in Mathematics for Use with the 2% and General Education Populations: Grade 3. Technical Report # 09-02

    ERIC Educational Resources Information Center

    Alonzo, Julie; Lai, Cheng Fei; Tindal, Gerald

    2009-01-01

    In this technical report, we describe the development and piloting of a series of mathematics progress monitoring measures intended for use with students in grades kindergarten through eighth grade. These measures, available as part of easyCBM[TM], an online progress monitoring assessment system, were developed in 2007 and 2008 and administered to…

  5. The Development of K-8 Progress Monitoring Measures in Mathematics for Use with the 2% and General Education Populations: Grade 2. Technical Report # 0920

    ERIC Educational Resources Information Center

    Alonzo, Julie; Lai, Cheng Fei; Tindal, Gerald

    2009-01-01

    In this technical report, we describe the development and piloting of a series of mathematics progress monitoring measures intended for use with students in grades kindergarten through eighth grade. These measures, available as part of easyCBM[TM], an online progress monitoring assessment system, were developed in 2007 and 2008 and administered to…

  6. The Development of K-8 Progress Monitoring Measures in Mathematics for Use with the 2% and General Education Populations: Grade 5. Technical Report # 09-01

    ERIC Educational Resources Information Center

    Lai, Cheng Fei; Alonzo, Julie; Tindal, Gerald

    2009-01-01

    In this technical report, we describe the development and piloting of a series of mathematics progress monitoring measures intended for use with students in grades kindergarten through eighth grade. These measures, available as part of easyCBM[TM], an online progress monitoring assessment system, were developed in 2007 and 2008 and administered to…

  7. The Development of K-8 Progress Monitoring Measures in Mathematics for Use with the 2% and General Education Populations: Grade 4. Technical Report # 09-03

    ERIC Educational Resources Information Center

    Alonzo, Julie; Lai, Cheng Fei; Tindal, Gerald

    2009-01-01

    In this technical report, we describe the development and piloting of a series of mathematics progress monitoring measures intended for use with students in grades kindergarten through eighth grade. These measures, available as part of easyCBM[TM], an online progress monitoring assessment system, were developed in 2007 and 2008 and administered to…

  8. The Development of K-8 Progress Monitoring Measures in Mathematics for Use with the 2% and General Education Populations: Grade 7. Technical Report 0908

    ERIC Educational Resources Information Center

    Lai, Cheng Fei; Alonzo, Julie; Tindal, Gerald

    2009-01-01

    In this technical report, we describe the development and piloting of a series of mathematics progress monitoring measures intended for use with students in grades kindergarten through eighth grade. These measures, available as part of easyCBM[TM], an online progress monitoring assessment system, were developed in 2007 and 2008 and administered to…

  9. The Development of K-8 Progress Monitoring Measures in Mathematics for Use with the 2% and General Education Populations: Grade 8. Technical Report # 09-04

    ERIC Educational Resources Information Center

    Lai, Cheng Fei; Alonzo, Julie; Tindal, Gerald

    2009-01-01

    In this technical report, we describe the development and piloting of a series of mathematics progress monitoring measures intended for use with students in grades kindergarten through eighth grade. These measures, available as part of easyCBM[TM], an online progress monitoring assessment system, were developed in 2007 and 2008 and administered to…

  10. 47 CFR 15.513 - Technical requirements for medical imaging systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Technical requirements for medical imaging systems. 15.513 Section 15.513 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES Ultra-Wideband Operation § 15.513 Technical requirements for medical imaging systems. (a) The UWB...

  11. [Concepts of development of the neurosurgical operative environment in the 21st century].

    PubMed

    Apuzzo, M; Liu, C

    2002-01-01

    The operative environment has to a large extent defines the "state of the art and science" of neurosurgery, which is now undergoing rapid reinvention. In order to remain current, each neurosurgeon should periodically reconsider their personal operative environment and its functional design with reference to modernity of practice as currently defined. Historical trends and their analysis offer predictive guides for development of such settings with an eye toward the future. Examination of technical developments in decade timeframes defines the progress in capability and need. Progressive minimalism of manipulation and the presence of operative definition with increasing precision are evident, with concurrent miniaturization of attendant computerized support systems, sensors, robotic interfaces, and imaging devices. These trends and developments offer the opportunity for simplificity of setting design with higher functionality as the desired endpoint.

  12. Visible rodent brain-wide networks at single-neuron resolution

    PubMed Central

    Yuan, Jing; Gong, Hui; Li, Anan; Li, Xiangning; Chen, Shangbin; Zeng, Shaoqun; Luo, Qingming

    2015-01-01

    There are some unsolvable fundamental questions, such as cell type classification, neural circuit tracing and neurovascular coupling, though great progresses are being made in neuroscience. Because of the structural features of neurons and neural circuits, the solution of these questions needs us to break through the current technology of neuroanatomy for acquiring the exactly fine morphology of neuron and vessels and tracing long-distant circuit at axonal resolution in the whole brain of mammals. Combined with fast-developing labeling techniques, efficient whole-brain optical imaging technology emerging at the right moment presents a huge potential in the structure and function research of specific-function neuron and neural circuit. In this review, we summarize brain-wide optical tomography techniques, review the progress on visible brain neuronal/vascular networks benefit from these novel techniques, and prospect the future technical development. PMID:26074784

  13. Development and Validation of a Novel Scoring System for Predicting Technical Success of Chronic Total Occlusion Percutaneous Coronary Interventions: The PROGRESS CTO (Prospective Global Registry for the Study of Chronic Total Occlusion Intervention) Score.

    PubMed

    Christopoulos, Georgios; Kandzari, David E; Yeh, Robert W; Jaffer, Farouc A; Karmpaliotis, Dimitri; Wyman, Michael R; Alaswad, Khaldoon; Lombardi, William; Grantham, J Aaron; Moses, Jeffrey; Christakopoulos, Georgios; Tarar, Muhammad Nauman J; Rangan, Bavana V; Lembo, Nicholas; Garcia, Santiago; Cipher, Daisha; Thompson, Craig A; Banerjee, Subhash; Brilakis, Emmanouil S

    2016-01-11

    This study sought to develop a novel parsimonious score for predicting technical success of chronic total occlusion (CTO) percutaneous coronary intervention (PCI) performed using the hybrid approach. Predicting technical success of CTO PCI can facilitate clinical decision making and procedural planning. We analyzed clinical and angiographic parameters from 781 CTO PCIs included in PROGRESS CTO (Prospective Global Registry for the Study of Chronic Total Occlusion Intervention) using a derivation and validation cohort (2:1 sampling ratio). Variables with strong association with technical success in multivariable analysis were assigned 1 point, and a 4-point score was developed from summing all points. The PROGRESS CTO score was subsequently compared with the J-CTO (Multicenter Chronic Total Occlusion Registry in Japan) score in the validation cohort. Technical success was 92.9%. On multivariable analysis, factors associated with technical success included proximal cap ambiguity (beta coefficient [b] = 0.88), moderate/severe tortuosity (b = 1.18), circumflex artery CTO (b = 0.99), and absence of "interventional" collaterals (b = 0.88). The resulting score demonstrated good calibration and discriminatory capacity in the derivation (Hosmer-Lemeshow chi-square = 2.633; p = 0.268, and receiver-operator characteristic [ROC] area = 0.778) and validation (Hosmer-Lemeshow chi-square = 5.333; p = 0.070, and ROC area = 0.720) subset. In the validation cohort, the PROGRESS CTO and J-CTO scores performed similarly in predicting technical success (ROC area 0.720 vs. 0.746, area under the curve difference = 0.026, 95% confidence interval = -0.093 to 0.144). The PROGRESS CTO score is a novel useful tool for estimating technical success in CTO PCI performed using the hybrid approach. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. 47 CFR 15.510 - Technical requirements for through D-wall imaging systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Technical requirements for through D-wall imaging systems. 15.510 Section 15.510 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES Ultra-Wideband Operation § 15.510 Technical requirements for through D-wall imaging...

  15. Reproducibility and variability of quantitative magnetic resonance imaging markers in cerebral small vessel disease

    PubMed Central

    De Guio, François; Jouvent, Eric; Biessels, Geert Jan; Black, Sandra E; Brayne, Carol; Chen, Christopher; Cordonnier, Charlotte; De Leeuw, Frank-Eric; Dichgans, Martin; Doubal, Fergus; Duering, Marco; Dufouil, Carole; Duzel, Emrah; Fazekas, Franz; Hachinski, Vladimir; Ikram, M Arfan; Linn, Jennifer; Matthews, Paul M; Mazoyer, Bernard; Mok, Vincent; Norrving, Bo; O’Brien, John T; Pantoni, Leonardo; Ropele, Stefan; Sachdev, Perminder; Schmidt, Reinhold; Seshadri, Sudha; Smith, Eric E; Sposato, Luciano A; Stephan, Blossom; Swartz, Richard H; Tzourio, Christophe; van Buchem, Mark; van der Lugt, Aad; van Oostenbrugge, Robert; Vernooij, Meike W; Viswanathan, Anand; Werring, David; Wollenweber, Frank; Wardlaw, Joanna M

    2016-01-01

    Brain imaging is essential for the diagnosis and characterization of cerebral small vessel disease. Several magnetic resonance imaging markers have therefore emerged, providing new information on the diagnosis, progression, and mechanisms of small vessel disease. Yet, the reproducibility of these small vessel disease markers has received little attention despite being widely used in cross-sectional and longitudinal studies. This review focuses on the main small vessel disease-related markers on magnetic resonance imaging including: white matter hyperintensities, lacunes, dilated perivascular spaces, microbleeds, and brain volume. The aim is to summarize, for each marker, what is currently known about: (1) its reproducibility in studies with a scan–rescan procedure either in single or multicenter settings; (2) the acquisition-related sources of variability; and, (3) the techniques used to minimize this variability. Based on the results, we discuss technical and other challenges that need to be overcome in order for these markers to be reliably used as outcome measures in future clinical trials. We also highlight the key points that need to be considered when designing multicenter magnetic resonance imaging studies of small vessel disease. PMID:27170700

  16. Visual Prostheses: The Enabling Technology to Give Sight to the Blind

    PubMed Central

    Maghami, Mohammad Hossein; Sodagar, Amir Masoud; Lashay, Alireza; Riazi-Esfahani, Hamid; Riazi-Esfahani, Mohammad

    2014-01-01

    Millions of patients are either slowly losing their vision or are already blind due to retinal degenerative diseases such as retinitis pigmentosa (RP) and age-related macular degeneration (AMD) or because of accidents or injuries. Employment of artificial means to treat extreme vision impairment has come closer to reality during the past few decades. Currently, many research groups work towards effective solutions to restore a rudimentary sense of vision to the blind. Aside from the efforts being put on replacing damaged parts of the retina by engineered living tissues or microfabricated photoreceptor arrays, implantable electronic microsystems, referred to as visual prostheses, are also sought as promising solutions to restore vision. From a functional point of view, visual prostheses receive image information from the outside world and deliver them to the natural visual system, enabling the subject to receive a meaningful perception of the image. This paper provides an overview of technical design aspects and clinical test results of visual prostheses, highlights past and recent progress in realizing chronic high-resolution visual implants as well as some technical challenges confronted when trying to enhance the functional quality of such devices. PMID:25709777

  17. Final report : for the period of December 1999 through November 30, 2000 : Florida Transit Training Program (1999/2000) : Florida Technical Assistance Program (1999/2000)

    DOT National Transportation Integrated Search

    2000-01-01

    The following progress report is intended to highlight the significant activities of the Florida Transit Training Program and Florida Technical Assistant Program. The following progress report is intended to highlight the significant activities of th...

  18. Annual progress report : for the period of January 2001 through December 2001 : Florida Transit Training Program (2001) : Florida Technical Assistance Program (2001)

    DOT National Transportation Integrated Search

    2001-01-01

    The following progress report is intended to highlight the significant activities of the Florida Transit Training Program and Florida Technical Assistant Program for the 2001 year. Activities of the Florida Statewide Transit Training Program are pres...

  19. Multispectral Filter Arrays: Recent Advances and Practical Implementation

    PubMed Central

    Lapray, Pierre-Jean; Wang, Xingbo; Thomas, Jean-Baptiste; Gouton, Pierre

    2014-01-01

    Thanks to some technical progress in interferencefilter design based on different technologies, we can finally successfully implement the concept of multispectral filter array-based sensors. This article provides the relevant state-of-the-art for multispectral imaging systems and presents the characteristics of the elements of our multispectral sensor as a case study. The spectral characteristics are based on two different spatial arrangements that distribute eight different bandpass filters in the visible and near-infrared area of the spectrum. We demonstrate that the system is viable and evaluate its performance through sensor spectral simulation. PMID:25407904

  20. 76 FR 64083 - Reliability Technical Conference; Notice of Technical Conference

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-17

    ... Technical Conference; Notice of Technical Conference Take notice that the Federal Energy Regulatory Commission will hold a Technical Conference on Tuesday, November 29, 2011, from 1 p.m. to 5 p.m. and... System. The conference will explore the progress made on the priorities for addressing risks to...

  1. 48 CFR 2052.211-70 - Preparation of technical reports.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....211-70 Preparation of technical reports. As prescribed at 2011.104-70(a), the contracting officer... Reports (JAN 1993) All technical reports required by Section C and all Technical Progress Reports required... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Preparation of technical...

  2. 48 CFR 2052.211-70 - Preparation of technical reports.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....211-70 Preparation of technical reports. As prescribed at 2011.104-70(a), the contracting officer... Reports (JAN 1993) All technical reports required by Section C and all Technical Progress Reports required... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Preparation of technical...

  3. 48 CFR 2052.211-70 - Preparation of technical reports.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ....211-70 Preparation of technical reports. As prescribed at 2011.104-70(a), the contracting officer... Reports (JAN 1993) All technical reports required by Section C and all Technical Progress Reports required... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Preparation of technical...

  4. 48 CFR 2052.211-70 - Preparation of technical reports.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....211-70 Preparation of technical reports. As prescribed at 2011.104-70(a), the contracting officer... Reports (JAN 1993) All technical reports required by Section C and all Technical Progress Reports required... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false Preparation of technical...

  5. 48 CFR 2052.211-70 - Preparation of technical reports.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....211-70 Preparation of technical reports. As prescribed at 2011.104-70(a), the contracting officer... Reports (JAN 1993) All technical reports required by Section C and all Technical Progress Reports required... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Preparation of technical...

  6. Resource Planning Model | Energy Analysis | NREL

    Science.gov Websites

    balancing authority. An image of a overlapping circles labelled Resource, Technical, Economic, and Market competing electricity technologies. An image of a overlapping circles labelled Resource, Technical, Economic ; Federal Resource Planning. Volume 1: Sectoral, Technical, and Economic Trends, NREL Technical Report (2016

  7. Neuroprotective "agents" in surgery. Secret "agent" man, or common "agent" machine?

    NASA Technical Reports Server (NTRS)

    Andrews, R. J.

    1999-01-01

    The search for clinically-effective neuroprotective agents has received enormous support in recent years--an estimated $200 million by pharmaceutical companies on clinical trials for traumatic brain injury alone. At the same time, the pathophysiology of brain injury has proved increasingly complex, rendering the likelihood of a single agent "magic bullet" even more remote. On the other hand, great progress continues with technology that makes surgery less invasive and less risky. One example is the application of endovascular techniques to treat coronary artery stenosis, where both the invasiveness of sternotomy and the significant neurological complication rate (due to microemboli showering the cerebral vasculature) can be eliminated. In this paper we review aspects of intraoperative neuroprotection both present and future. Explanations for the slow progress on pharmacologic neuroprotection during surgery are presented. Examples of technical advances that have had great impact on neuroprotection during surgery are given both from coronary artery stenosis surgery and from surgery for Parkinson's disease. To date, the progress in neuroprotection resulting from such technical advances is an order of magnitude greater than that resulting from pharmacologic agents used during surgery. The progress over the last 20 years in guidance during surgery (CT and MRI image-guidance) and in surgical access (endoscopic and endovascular techniques) will soon be complemented by advances in our ability to evaluate biological tissue intraoperatively in real-time. As an example of such technology, the NASA Smart Probe project is considered. In the long run (i.e., in 10 years or more), pharmacologic "agents" aimed at the complex pathophysiology of nervous system injury in man will be the key to true intraoperative neuroprotection. In the near term, however, it is more likely that mundane "agents" based on computers, microsensors, and microeffectors will be the major impetus to improved intraoperative neuroprotection.

  8. Technical aspects of cardiac PET/MRI.

    PubMed

    Masuda, Atsuro; Nemoto, Ayaka; Takeishi, Yasuchika

    2018-06-01

    PET/MRI is a novel modality that enables to combine PET and MR images, and has significant potential to evaluate various cardiac diseases through the combination of PET molecular imaging and MRI functional imaging. Precise management of technical issues, however, is necessary for cardiac PET/MRI. This article describes several technical points, including patient preparation, MR attenuation correction, parallel acquisition of PET with MRI, clinical aspects, and image quality control.

  9. REACTOR PHYSICS QUARTERLY REPORT JANUARY, FEBRUARY, MARCH 1970

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmid, L. C.; Clayton, E. D.; Heineman, R. E.

    1970-05-01

    The objective of the Reactor Physics Quarterly Report is to inform the scientific community in a timely manner of the technical progress made on the many phases of reactor physics work within the laboratory. The report contains brief technical discussions of accomplishments in all areas where significant progress has been made during the quarter.

  10. George A. Olah, Carbocation and Hydrocarbon Chemistry

    Science.gov Websites

    . Final Technical Report. [HF:BF{sub 2}/H{sub 2}] , DOE Technical Report, 1980 Superacid Catalyzed Coal Conversion Chemistry. 1st and 2nd Quarterly Technical Progress Reports, September 1, 1983-March 30, 1984 , DOE Technical Report, 1984 Superacid Catalyzed Coal Conversion Chemistry. Final Technical Report

  11. HKHC Community Dashboard: design, development, and function of a Web-based performance monitoring system.

    PubMed

    Bors, Philip A; Kemner, Allison; Fulton, John; Stachecki, Jessica; Brennan, Laura K

    2015-01-01

    As part of Robert Wood Johnson Foundation's Healthy Kids, Healthy Communities (HKHC) national grant program, a technical assistance team designed the HKHC Community Dashboard, an online progress documentation and networking system. The Dashboard was central to HKHC's multimethod program evaluation and became a communication interface for grantees and technical assistance providers. The Dashboard was designed through an iterative process of identifying needs and priorities; designing the user experience, technical development, and usability testing; and applying visual design. The system was created with an open-source content management system and support for building an online community of users. The site developer trained technical assistance providers at the national program office and evaluators, who subsequently trained all 49 grantees. Evaluators provided support for Dashboard users and populated the site with the bulk of its uploaded tools and resource documents. The system tracked progress through an interactive work plan template, regular documentation by local staff and partners, and data coding and analysis by the evaluation team. Other features included the ability to broadcast information to Dashboard users via e-mail, event calendars, discussion forums, private messaging, a resource clearinghouse, a technical assistance diary, and real-time progress reports. The average number of Dashboard posts was 694 per grantee during the grant period. Technical assistance providers and grantees uploaded a total of 1304 resource documents. The Dashboard functions with the highest grantee satisfaction were its interfaces for sharing and progress documentation. A majority of Dashboard users (69%) indicated a preference for continued access to the Dashboard's uploaded resource documents. The Dashboard was a useful and innovative tool for participatory evaluation of a large national grant program. While progress documentation added some burden to local project staff, the system proved to be a useful resource-sharing technology.

  12. Modeling the impacts of climate change and technical progress on the wheat yield in inland China: An autoregressive distributed lag approach.

    PubMed

    Zhai, Shiyan; Song, Genxin; Qin, Yaochen; Ye, Xinyue; Lee, Jay

    2017-01-01

    This study aims to evaluate the impacts of climate change and technical progress on the wheat yield per unit area from 1970 to 2014 in Henan, the largest agricultural province in China, using an autoregressive distributed lag approach. The bounded F-test for cointegration among the model variables yielded evidence of a long-run relationship among climate change, technical progress, and the wheat yield per unit area. In the long run, agricultural machinery and fertilizer use both had significantly positive impacts on the per unit area wheat yield. A 1% increase in the aggregate quantity of fertilizer use increased the wheat yield by 0.19%. Additionally, a 1% increase in machine use increased the wheat yield by 0.21%. In contrast, precipitation during the wheat growth period (from emergence to maturity, consisting of the period from last October to June) led to a decrease in the wheat yield per unit area. In the short run, the coefficient of the aggregate quantity of fertilizer used was negative. Land size had a significantly positive impact on the per unit area wheat yield in the short run. There was no significant short-run or long-run impact of temperature on the wheat yield per unit area in Henan Province. The results of our analysis suggest that climate change had a weak impact on the wheat yield, while technical progress played an important role in increasing the wheat yield per unit area. The results of this study have implications for national and local agriculture policies under climate change. To design well-targeted agriculture adaptation policies for the future and to reduce the adverse effects of climate change on the wheat yield, climate change and technical progress factors should be considered simultaneously. In addition, adaptive measures associated with technical progress should be given more attention.

  13. Modeling the impacts of climate change and technical progress on the wheat yield in inland China: An autoregressive distributed lag approach

    PubMed Central

    Qin, Yaochen; Lee, Jay

    2017-01-01

    This study aims to evaluate the impacts of climate change and technical progress on the wheat yield per unit area from 1970 to 2014 in Henan, the largest agricultural province in China, using an autoregressive distributed lag approach. The bounded F-test for cointegration among the model variables yielded evidence of a long-run relationship among climate change, technical progress, and the wheat yield per unit area. In the long run, agricultural machinery and fertilizer use both had significantly positive impacts on the per unit area wheat yield. A 1% increase in the aggregate quantity of fertilizer use increased the wheat yield by 0.19%. Additionally, a 1% increase in machine use increased the wheat yield by 0.21%. In contrast, precipitation during the wheat growth period (from emergence to maturity, consisting of the period from last October to June) led to a decrease in the wheat yield per unit area. In the short run, the coefficient of the aggregate quantity of fertilizer used was negative. Land size had a significantly positive impact on the per unit area wheat yield in the short run. There was no significant short-run or long-run impact of temperature on the wheat yield per unit area in Henan Province. The results of our analysis suggest that climate change had a weak impact on the wheat yield, while technical progress played an important role in increasing the wheat yield per unit area. The results of this study have implications for national and local agriculture policies under climate change. To design well-targeted agriculture adaptation policies for the future and to reduce the adverse effects of climate change on the wheat yield, climate change and technical progress factors should be considered simultaneously. In addition, adaptive measures associated with technical progress should be given more attention. PMID:28950027

  14. Supply Chain Sustainability Analysis of Whole Algae Hydrothermal Liquefaction and Upgrading

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pegallapati, Ambica Koushik; Dunn, Jennifer B.; Frank, Edward D.

    2015-04-01

    The Department of Energy's Bioenergy Technology Office (BETO) collaborates with a wide range of institutions towards the development and deployment of biofuels and bioproducts. To facilitate this effort, BETO and its partner national laboratories develop detailed techno-economic assessments (TEA) of biofuel production technologies as part of the development of design cases and state of technology (SOT) analyses. A design case is a TEA that outlines a target case for a particular biofuel pathway. It enables preliminary identification of data gaps and research and development needs and provides goals and targets against which technology progress is assessed. On the other hand,more » an SOT analysis assesses progress within and across relevant technology areas based on actual experimental results relative to technical targets and cost goals from design cases and includes technical, economic, and environmental criteria as available. (SOT) analyses. A design case is a TEA that outlines a target case for a particular biofuel pathway. It enables preliminary identification of data gaps and research and development needs and provides goals and targets against which technology progress is assessed. On the other hand, an SOT analysis assesses progress within and across relevant technology areas based on actual experimental results relative to technical targets and cost goals from design cases and includes technical, economic, and environmental criteria as available. (SOT) analyses. A design case is a TEA that outlines a target case for a particular biofuel pathway. It enables preliminary identification of data gaps and research and development needs and provides goals and targets against which technology progress is assessed. On the other hand, an SOT analysis assesses progress within and across relevant technology areas based on actual experimental results relative to technical targets and cost goals from design cases and includes technical, economic, and environmental criteria as available.« less

  15. [Digital imaging and robotics in endoscopic surgery].

    PubMed

    Go, P M

    1998-05-23

    The introduction of endoscopical surgery has among other things influenced technical developments in surgery. Owing to digitalisation, major progress will be made in imaging and in the sophisticated technology sometimes called robotics. Digital storage makes the results of imaging diagnostics (e.g. the results of radiological examination) suitable for transmission via video conference systems for telediagnostic purposes. The availability of digital video technique renders possible the processing, storage and retrieval of moving images as well. During endoscopical operations use may be made of a robot arm which replaces the camera man. The arm does not grow tired and provides a stable image. The surgeon himself can operate or address the arm and it can remember fixed image positions to which it can return if ordered to do so. The next step is to carry out surgical manipulations via a robot arm. This may make operations more patient-friendly. A robot arm can also have remote control: telerobotics. At the Internet site of this journal a number of supplements to this article can be found, for instance three-dimensional (3D) illustrations (which is the purpose of the 3D spectacles enclosed with this issue) and a quiz (http:@appendix.niwi. knaw.nl).

  16. Research into the usage of integrated jamming of IR weakening and smoke-screen resisting the IR imaging guided missiles

    NASA Astrophysics Data System (ADS)

    Wang, Long-tao; Jiang, Ning; Lv, Ming-shan

    2015-10-01

    With the emergence of the anti-ship missle with the capability of infrared imaging guidance, the traditional single jamming measures, because of the jamming mechanism and technical flaws or unsuitable use, greatly reduced the survival probability of the war-ship in the future naval battle. Intergrated jamming of IR weakening + smoke-screen Can not only make jamming to the search and tracking of IR imaging guidance system , but also has feasibility in conjunction, besides , which also make the best jamming effect. The research conclusion has important realistic meaning for raising the antimissile ability of surface ships. With the development of guidance technology, infrared guidance system has expanded by ir point-source homing guidance to infrared imaging guidance, Infrared imaging guidance has made breakthrough progress, Infrared imaging guidance system can use two-dimensional infrared image information of the target, achieve the precise tracking. Which has Higher guidance precision, better concealment, stronger anti-interference ability and could Target the key parts. The traditional single infrared smoke screen jamming or infrared decoy flare interference cannot be imposed effective interference. So, Research how to effectively fight against infrared imaging guided weapons threat measures and means, improving the surface ship antimissile ability is an urgent need to solve.

  17. Infrared Thermal Testing Of Mechanical Assemblies At The Military Depot And Field Level: A Progress Report

    NASA Astrophysics Data System (ADS)

    Kaplan, Herbert

    1988-01-01

    Based on encouraging results on the Army's programs for infrared mass screening of printed circuit boards at the depot level, the US Army CECOM (Communication-Electronics Command) undertook a one-year investigation of the applicability of similar techniques to screening and diagnostics of mechanical assemblies. These included tanks, helicopters, transport vehicles and their major subassemblies (transmissions, engines, axles, etc.) at field and depot levels. Honeyhill Technical Company was tasked to classify candidate assemblies and perform preliminary measurements using Army-owned general-purpose thermal imaging equipment. The investigations yielded positive results, and it was decided to pursue a comprehensive measurements program using field-mobile equipment specifically procured for the program. This paper summarizes the results of the investigations, outlines the measurements techniques utilized, describes the classification and selection of candidate assemblies, and reports on progress toward the goals of the program.

  18. The OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging (MRI) Scoring System: Updated Recommendations by the OMERACT MRI in Arthritis Working Group.

    PubMed

    Østergaard, Mikkel; Peterfy, Charles G; Bird, Paul; Gandjbakhch, Frédérique; Glinatsi, Daniel; Eshed, Iris; Haavardsholm, Espen A; Lillegraven, Siri; Bøyesen, Pernille; Ejbjerg, Bo; Foltz, Violaine; Emery, Paul; Genant, Harry K; Conaghan, Philip G

    2017-11-01

    The Outcome Measures in Rheumatology (OMERACT) Rheumatoid Arthritis (RA) Magnetic Resonance Imaging (MRI) scoring system (RAMRIS), evaluating bone erosion, bone marrow edema/osteitis, and synovitis, was introduced in 2002, and is now the standard method of objectively quantifying inflammation and damage by MRI in RA trials. The objective of this paper was to identify subsequent advances and based on them, to provide updated recommendations for the RAMRIS. MRI studies relevant for RAMRIS and technical and scientific advances were analyzed by the OMERACT MRI in Arthritis Working Group, which used these data to provide updated considerations on image acquisition, RAMRIS definitions, and scoring systems for the original and new RA pathologies. Further, a research agenda was outlined. Since 2002, longitudinal studies and clinical trials have documented RAMRIS variables to have face, construct, and criterion validity; high reliability and sensitivity to change; and the ability to discriminate between therapies. This has enabled RAMRIS to demonstrate inhibition of structural damage progression with fewer patients and shorter followup times than has been possible with conventional radiography. Technical improvements, including higher field strengths and improved pulse sequences, allow higher image resolution and contrast-to-noise ratio. These have facilitated development and validation of scoring methods of new pathologies: joint space narrowing and tenosynovitis. These have high reproducibility and moderate sensitivity to change, and can be added to RAMRIS. Combined scores of inflammation or joint damage may increase sensitivity to change and discriminative power. However, this requires further research. Updated 2016 RAMRIS recommendations and a research agenda were developed.

  19. Technical Adequacy of Growth Estimates from a Computer Adaptive Test: Implications for Progress Monitoring

    ERIC Educational Resources Information Center

    Van Norman, Ethan R.; Nelson, Peter M.; Parker, David C.

    2017-01-01

    Computer adaptive tests (CATs) hold promise to monitor student progress within multitiered systems of support. However, the relationship between how long and how often data are collected and the technical adequacy of growth estimates from CATs has not been explored. Given CAT administration times, it is important to identify optimal data…

  20. Education, Industrialization and Technical Progress in Mexico. IIEP Research Report No. 6.

    ERIC Educational Resources Information Center

    Padua, Jorge

    This report attempts to analyze the contributions of the educational system and job training programs to industrialization and technical progress in the Conubal zone of the Lower Balsas River of Mexico. The first of the study's three sections consists of two chapters that provide general background. Chapter 1, "Theories of Development and the…

  1. Technical Adequacy and Acceptability of Curriculum-Based Measurement and the Measures of Academic Progress

    ERIC Educational Resources Information Center

    January, Stacy-Ann A.; Ardoin, Scott P.

    2015-01-01

    Curriculum-based measurement in reading (CBM-R) and the Measures of Academic Progress (MAP) are assessment tools widely employed for universal screening in schools. Although a large body of research supports the validity of CBM-R, limited empirical evidence exists supporting the technical adequacy of MAP or the acceptability of either measure for…

  2. Annual Technical Progress Report for Emergency School Assistance Program, Title 45, 1970-71.

    ERIC Educational Resources Information Center

    Lindsey, Randall B.

    This paper presents a technical progress report of two programs conducted with funds provided under the Emergency School Assistance Program. One, the Mobile Learning Unit, said to have been designed to measure changes in fourth and fifth grade students' self-concept in a reorganized desegregated school environment, focuses on whether a positive…

  3. Third Progress and Information Report of the Vocational-Technical Education Consortium of States.

    ERIC Educational Resources Information Center

    Lee, Connie W.; And Others

    This description of major activities and accomplishments of the Vocational-Technical Education Consortium of the States (V-TECS) since the second progress report of May, 1975, is designed to provide the reader with a basic understanding of the processes and procedures used by the consortium in achieving its major goal: The production of catalogs…

  4. A PSFI-based analysis on the energy efficiency potential of China’s domestic passenger vehicles

    NASA Astrophysics Data System (ADS)

    Chen, Chuan; Ren, Huanhuan; Zhao, Dongchang

    2017-01-01

    In this article, China’s domestic passenger vehicles (excluding new energy vehicles) are categorized into two groups: local brand vehicles and vehicles manufactured by joint ventures. Performance-Size-Fuel economy Index (PSFI) will be applied to analyse the speed of technical progress and the future trends of these vehicles. In addition, a forecast on energy efficiency potential of domestic passenger vehicles from 2016 to 2020 will be made based on different Emphasis on Reducing Fuel Consumption (ERFC) scenarios. According to the study, if the process of technical progress continues at its current speed, domestic ICE passenger vehicles will hardly meet Phase IV requirements by 2020 even though companies contribute as much technical progress to fuel consumption reduction as possible.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stout, D.K.

    Flaws are noted in equilibrium growth models which ignore the facts that labor is no longer homogeneous, national governments can no longer guarantee a managed demand, and technical progress is not an independent force. The pace of technical progress is the major variable and increases with competition and certainty in the growth of demand. The outlook for technical progress is examined in the context of productivity, using microprocessor development for illustration. The author takes an optimistic view of new developments in that they do not bring the self-destructive possibility of overpopulation, irreversible damage to the environment, or nuclear war anymore » closer, while having a positive chance to promote a more rewarding relationship between education, work, and life style. The opportunities for positive humanistic changes through microprocessing are confirmed. (DCK)« less

  6. Design of the 2D electron cyclotron emission imaging instrument for the J-TEXT tokamak.

    PubMed

    Pan, X M; Yang, Z J; Ma, X D; Zhu, Y L; Luhmann, N C; Domier, C W; Ruan, B W; Zhuang, G

    2016-11-01

    A new 2D Electron Cyclotron Emission Imaging (ECEI) diagnostic is being developed for the J-TEXT tokamak. It will provide the 2D electron temperature information with high spatial, temporal, and temperature resolution. The new ECEI instrument is being designed to support fundamental physics investigations on J-TEXT including MHD, disruption prediction, and energy transport. The diagnostic contains two dual dipole antenna arrays corresponding to F band (90-140 GHz) and W band (75-110 GHz), respectively, and comprises a total of 256 channels. The system can observe the same magnetic surface at both the high field side and low field side simultaneously. An advanced optical system has been designed which permits the two arrays to focus on a wide continuous region or two radially separate regions with high imaging spatial resolution. It also incorporates excellent field curvature correction with field curvature adjustment lenses. An overview of the diagnostic and the technical progress including the new remote control technique are presented.

  7. Design of the 2D electron cyclotron emission imaging instrument for the J-TEXT tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pan, X. M.; Yang, Z. J., E-mail: yangzj@hust.edu.cn; Ma, X. D.

    2016-11-15

    A new 2D Electron Cyclotron Emission Imaging (ECEI) diagnostic is being developed for the J-TEXT tokamak. It will provide the 2D electron temperature information with high spatial, temporal, and temperature resolution. The new ECEI instrument is being designed to support fundamental physics investigations on J-TEXT including MHD, disruption prediction, and energy transport. The diagnostic contains two dual dipole antenna arrays corresponding to F band (90-140 GHz) and W band (75-110 GHz), respectively, and comprises a total of 256 channels. The system can observe the same magnetic surface at both the high field side and low field side simultaneously. An advancedmore » optical system has been designed which permits the two arrays to focus on a wide continuous region or two radially separate regions with high imaging spatial resolution. It also incorporates excellent field curvature correction with field curvature adjustment lenses. An overview of the diagnostic and the technical progress including the new remote control technique are presented.« less

  8. Genetically Encoded Voltage Indicators: Opportunities and Challenges

    PubMed Central

    Yang, Helen H.

    2016-01-01

    A longstanding goal in neuroscience is to understand how spatiotemporal patterns of neuronal electrical activity underlie brain function, from sensory representations to decision making. An emerging technology for monitoring electrical dynamics, voltage imaging using genetically encoded voltage indicators (GEVIs), couples the power of genetics with the advantages of light. Here, we review the properties that determine indicator performance and applicability, discussing both recent progress and technical limitations. We then consider GEVI applications, highlighting studies that have already deployed GEVIs for biological discovery. We also examine which classes of biological questions GEVIs are primed to address and which ones are beyond their current capabilities. As GEVIs are further developed, we anticipate that they will become more broadly used by the neuroscience community to eavesdrop on brain activity with unprecedented spatiotemporal resolution. SIGNIFICANCE STATEMENT Genetically encoded voltage indicators are engineered light-emitting protein sensors that typically report neuronal voltage dynamics as changes in brightness. In this review, we systematically discuss the current state of this emerging method, considering both its advantages and limitations for imaging neural activity. We also present recent applications of this technology and discuss what is feasible now and what we anticipate will become possible with future indicator development. This review will inform neuroscientists of recent progress in the field and help potential users critically evaluate the suitability of genetically encoded voltage indicator imaging to answer their specific biological questions. PMID:27683896

  9. Index to Nuclear Safety. A technical progress review by chronology, permuted title, and author. Vol. 11, No. 1--Vol. 17, No. 6

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cottrell, W.B.; Klein, A.

    1977-02-23

    This index to Nuclear Safety covers articles in Nuclear Safety Vol. 11, No. 1 (Jan.-Feb. 1970), through Vol. 17, No. 6 (Nov.-Dec. 1976). The index includes a chronological list of articles (including abstract) followed by KWIC and Author Indexes. Nuclear Safety, a bimonthly technical progress review prepared by the Nuclear Safety Information Center, covers all safety aspects of nuclear power reactors and associated facilities. The index lists over 350 technical articles in the last six years of publication.

  10. [Address Given at the Regional Junior College Recreation Education Institute, American River College, September 25, 1969.

    ERIC Educational Resources Information Center

    Lutzin, Sidney G.

    The United States has made striking technical advances in recent years, but there has not been comparable progress in social services. Greater affluence and leisure for some have been one result of technical progress, but problems of poverty and urban development are more pressing. New developments to improve the condition of society can be…

  11. THE DEVELOPMENT OF PRE-VOCATIONAL EDUCATION LITERACY COURSES FOR USE WITH COMPUTER ASSISTED INSTRUCTION OF DISADVANTAGED YOUTH AND ADULTS. TECHNICAL PROGRESS REPORT.

    ERIC Educational Resources Information Center

    HANKIN, EDWARD K.; AND OTHERS

    THIS TECHNICAL PROGRESS REPORT COVERS THE FIRST THREE MONTHS OF A PROJECT TO DEVELOP COMPUTER ASSISTED PREVOCATIONAL READING AND ARITHMETIC COURSES FOR DISADVANTAGED YOUTHS AND ADULTS. DURING THE FIRST MONTH OF OPERATION, PROJECT PERSONNEL CONCENTRATED ON SUCH ADMINISTRATIVE MATTERS AS TRAINING STAFF AND PREPARING FACILITIES. AN ARITHMETIC PROGRAM…

  12. Generation and focusing of pulsed intense ion beams. Technical progress report, 20 August 1981-30 September 1982

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hammer, D.A.; Kusse, B.R.; Sudan, R.N.

    1983-07-01

    The progress on this contract is described in two parts. The first deals with the technical operation of the LION accelerator which is the exact equivalent to one line of PBFA-I. The second part is concerned with the experimental results on the ion diode mounted at the front end of the LION accelerator.

  13. Project LIFE--Language Improvement to Facilitate Education. (Technical Progress Report; Third Quarter; March 1, 1974-May 31, 1974).

    ERIC Educational Resources Information Center

    National Foundation for the Improvement of Education, Washington, DC.

    Reported is the third quarter, fiscal year 1974 (March 1, 1974-May 31, 1974) technical progress of Project LIFE (Language Improvement to Facilitate Education), toward developing an instructional system in which filmstrips in the areas of perceptual training, perceptual thinking, and language/reading are used to assist hearing impaired children in…

  14. 47 CFR 15.509 - Technical requirements for ground penetrating radars and wall imaging systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Technical requirements for ground penetrating radars and wall imaging systems. 15.509 Section 15.509 Telecommunication FEDERAL COMMUNICATIONS... ground penetrating radars and wall imaging systems. (a) The UWB bandwidth of an imaging system operating...

  15. 47 CFR 15.509 - Technical requirements for ground penetrating radars and wall imaging systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Technical requirements for ground penetrating radars and wall imaging systems. 15.509 Section 15.509 Telecommunication FEDERAL COMMUNICATIONS... ground penetrating radars and wall imaging systems. (a) The UWB bandwidth of an imaging system operating...

  16. 47 CFR 15.509 - Technical requirements for ground penetrating radars and wall imaging systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Technical requirements for ground penetrating radars and wall imaging systems. 15.509 Section 15.509 Telecommunication FEDERAL COMMUNICATIONS... ground penetrating radars and wall imaging systems. (a) The UWB bandwidth of an imaging system operating...

  17. 47 CFR 15.509 - Technical requirements for ground penetrating radars and wall imaging systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Technical requirements for ground penetrating radars and wall imaging systems. 15.509 Section 15.509 Telecommunication FEDERAL COMMUNICATIONS... ground penetrating radars and wall imaging systems. (a) The UWB bandwidth of an imaging system operating...

  18. 47 CFR 15.509 - Technical requirements for ground penetrating radars and wall imaging systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Technical requirements for ground penetrating radars and wall imaging systems. 15.509 Section 15.509 Telecommunication FEDERAL COMMUNICATIONS... ground penetrating radars and wall imaging systems. (a) The UWB bandwidth of an imaging system operating...

  19. Valorisation of urban elements through 3D models generated from image matching point clouds and augmented reality visualization based in mobile platforms

    NASA Astrophysics Data System (ADS)

    Marques, Luís.; Roca Cladera, Josep; Tenedório, José António

    2017-10-01

    The use of multiple sets of images with high level of overlapping to extract 3D point clouds has increased progressively in recent years. There are two main fundamental factors in the origin of this progress. In first, the image matching algorithms has been optimised and the software available that supports the progress of these techniques has been constantly developed. In second, because of the emergent paradigm of smart cities which has been promoting the virtualization of urban spaces and their elements. The creation of 3D models for urban elements is extremely relevant for urbanists to constitute digital archives of urban elements and being especially useful for enrich maps and databases or reconstruct and analyse objects/areas through time, building and recreating scenarios and implementing intuitive methods of interaction. These characteristics assist, for example, higher public participation creating a completely collaborative solution system, envisioning processes, simulations and results. This paper is organized in two main topics. The first deals with technical data modelling obtained by terrestrial photographs: planning criteria for obtaining photographs, approving or rejecting photos based on their quality, editing photos, creating masks, aligning photos, generating tie points, extracting point clouds, generating meshes, building textures and exporting results. The application of these procedures results in 3D models for the visualization of urban elements of the city of Barcelona. The second concerns the use of Augmented Reality through mobile platforms allowing to understand the city origins and the relation with the actual city morphology, (en)visioning solutions, processes and simulations, making possible for the agents in several domains, to fundament their decisions (and understand them) achieving a faster and wider consensus.

  20. Monitoring the Durability Performance of Concrete in Nuclear Waste Containment. Technical Progress Report No. 4

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ulm, Franz-Josef

    2000-06-30

    OAK-B135 Monitoring the Durability Performance of Concrete in Nuclear Waste Containment. Technical Progress Report No. 4. The analysis of the effect of cracks on the acceleration of the calcium leaching process of cement-based materials has been pursued. During the last period (Technical Progress Report No 3), we have introduced a modeling accounting for the high diffusivity of fractures in comparison with the weak solid material diffusivity. It has been shown through dimensional and asymptotic analysis that small fractures do not significantly accelerate the material aging process. This important result for the overall structural aging kinetics of containment structure has beenmore » developed in a paper submitted to the international journal ''Transport in Porous Media''.« less

  1. Technical aspects of CT imaging of the spine.

    PubMed

    Tins, Bernhard

    2010-11-01

    This review article discusses technical aspects of computed tomography (CT) imaging of the spine. Patient positioning, and its influence on image quality and movement artefact, is discussed. Particular emphasis is placed on the choice of scan parameters and their relation to image quality and radiation burden to the patient. Strategies to reduce radiation burden and artefact from metal implants are outlined. Data acquisition, processing, image display and steps to reduce artefact are reviewed. CT imaging of the spine is put into context with other imaging modalities for specific clinical indications or problems. This review aims to review underlying principles for image acquisition and to provide a rough guide for clinical problems without being prescriptive. Individual practice will always vary and reflect differences in local experience, technical provisions and clinical requirements.

  2. Department of Clinical Investigation Annual Research Progress Report, Fiscal Year 1984. Volume 1,

    DTIC Science & Technology

    1984-10-01

    on a low dosage of medication . Technical Approach: None. Progress: The placebo has not been received from the company. Since the drug company...determine the effect of high dose Ar-C intensification therapy on the -. incidence of CNS relapse. - Technical Approach: All patients with a new...Enrolled to Date: 7 Date of Periodic Review Results Objective(s): To determine the incidence of

  3. Effect of Tumor Complexity and Technique on Efficacy and Complications after Percutaneous Microwave Ablation of Stage T1a Renal Cell Carcinoma: A Single-Center, Retrospective Study.

    PubMed

    Klapperich, Marki E; Abel, E Jason; Ziemlewicz, Timothy J; Best, Sara; Lubner, Meghan G; Nakada, Stephen Y; Hinshaw, J Louis; Brace, Christopher L; Lee, Fred T; Wells, Shane A

    2017-07-01

    Purpose To evaluate the effects of tumor complexity and technique on early and midterm oncologic efficacy and rate of complications for 100 consecutive biopsy-proved stage T1a renal cell carcinomas (RCCs) treated with percutaneous microwave ablation. Materials and Methods This HIPAA-compliant, single-center retrospective study was approved by the institutional review board. The requirement to obtain informed consent was waived. Ninety-six consecutive patients (68 men, 28 women; mean age, 66 years ± 9.4) with 100 stage T1a N0M0 biopsy-proved RCCs (median diameter, 2.6 cm ± 0.8) underwent percutaneous microwave ablation between March 2011 and June 2015. Patient and procedural data were collected, including body mass index, comorbidities, tumor histologic characteristics and grade, RENAL nephrometry score, number of antennas, generator power, and duration of ablation. Technical success, local tumor progression, and presence of complications were assessed at immediate and follow-up imaging. The Kaplan-Meier method was used for survival analyses. Results Technical success was achieved for all 100 tumors (100%), including 47 moderately and five highly complex RCCs. Median clinical and imaging follow-up was 17 months (range, 0-48 months) and 15 months (range, 0-44 months), respectively. No change in estimated glomerular filtration rate was noted after the procedure (P = .49). There were three (3%) procedure-related complications and six (6%) delayed complications, all urinomas. One case of local tumor progression (1%) was identified 25 months after the procedure. Three-year local progression-free survival, cancer-specific survival, and overall survival were 88% (95% confidence interval: 0.52%, 0.97%), 100% (95% confidence interval: 1.0%, 1.0%), and 91% (95% confidence interval: 0.51%, 0.99%), respectively. Conclusion Percutaneous microwave ablation is an effective and safe treatment option for stage T1a RCC, regardless of tumor complexity. Long-term follow-up is needed to establish durable oncologic efficacy and survival relative to competing ablation modalities and surgery. © RSNA, 2017.

  4. Traumatic cervical internal carotid artery pseudoaneurysm in a child refractory to initial endovascular treatment: case report and technical considerations.

    PubMed

    Wang, Arthur; Santarelli, Justin G; Stiefel, Michael F

    2016-12-01

    Optimal management of extracranial carotid artery dissections (eCAD) in pediatric patients is not well documented, and endovascular interventions are rarely reported. A 10-year-old girl sustained multiple systemic injuries in a motor vehicle accident, including an eCAD with pseudoaneurysm. She initially failed both aspirin and endovascular stenting with progressive enlargement of a traumatic cervical carotid pseudoaneurysm and stenosis. Second-stage endovascular stent placement with coiling resulted in successful occlusion of the pseudoaneurysm. At 30-month imaging follow-up, the parent vessel remained patent with no evidence of the pseudoaneurysm. In the setting of poly-trauma, management of eCAD can be complex especially in the pediatric population. There is little data on the endovascular treatment of eCAD in children. Failed endovascular therapies are extremely rare. Our report supports surveillance imaging as repeat endovascular treatment may be necessary.

  5. Recent advances in parametric neuroreceptor mapping with dynamic PET: basic concepts and graphical analyses.

    PubMed

    Seo, Seongho; Kim, Su Jin; Lee, Dong Soo; Lee, Jae Sung

    2014-10-01

    Tracer kinetic modeling in dynamic positron emission tomography (PET) has been widely used to investigate the characteristic distribution patterns or dysfunctions of neuroreceptors in brain diseases. Its practical goal has progressed from regional data quantification to parametric mapping that produces images of kinetic-model parameters by fully exploiting the spatiotemporal information in dynamic PET data. Graphical analysis (GA) is a major parametric mapping technique that is independent on any compartmental model configuration, robust to noise, and computationally efficient. In this paper, we provide an overview of recent advances in the parametric mapping of neuroreceptor binding based on GA methods. The associated basic concepts in tracer kinetic modeling are presented, including commonly-used compartment models and major parameters of interest. Technical details of GA approaches for reversible and irreversible radioligands are described, considering both plasma input and reference tissue input models. Their statistical properties are discussed in view of parametric imaging.

  6. Technical advances power neuroscience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barinaga, M.

    New techniques are helping researchers study the development of nerve cells in cell cultures and in vivo. These new methods are offering insights into the brain that were not available even a couple of years ago. Among the new advances discussed are imaging technology for evaluating the thinking human brain. One area in which researchers have made recent progress is the quest for ways to create immortal cell lines from specific types of nerve cells. Other projects using genetically engineered retroviruses and tumor-inducing genes, as well as gene regulation are discussed. Recent advances in neuroscience techniques apply not only tomore » neurons, but also to whole brains as well. One example is a high-resulution electroencephalogram (EEG). Although the EEG cannot pin down the actual sites of activity as precisely as static brain imaging methods, it complements them with real-time recording that can keep up with the very rapid pace of brain activity.« less

  7. Progress in the Correlative Atomic Force Microscopy and Optical Microscopy

    PubMed Central

    Zhou, Lulu; Cai, Mingjun; Tong, Ti; Wang, Hongda

    2017-01-01

    Atomic force microscopy (AFM) has evolved from the originally morphological imaging technique to a powerful and multifunctional technique for manipulating and detecting the interactions between molecules at nanometer resolution. However, AFM cannot provide the precise information of synchronized molecular groups and has many shortcomings in the aspects of determining the mechanism of the interactions and the elaborate structure due to the limitations of the technology, itself, such as non-specificity and low imaging speed. To overcome the technical limitations, it is necessary to combine AFM with other complementary techniques, such as fluorescence microscopy. The combination of several complementary techniques in one instrument has increasingly become a vital approach to investigate the details of the interactions among molecules and molecular dynamics. In this review, we reported the principles of AFM and optical microscopy, such as confocal microscopy and single-molecule localization microscopy, and focused on the development and use of correlative AFM and optical microscopy. PMID:28441775

  8. Imaging and quantitative measurement of corrosion in painted automotive and aircraft structures

    NASA Astrophysics Data System (ADS)

    Sun, G.; Wang, Xun; Feng, Z. J.; Jin, Huijia; Sui, Hua; Ouyang, Zhong; Han, Xiaoyan; Favro, L. D.; Thomas, R. L.; Bomback, J. L.

    2000-05-01

    Some of the authors have shown that it is possible to image and make rapid, quantitative measurements of metal thickness loss due to corrosion on the rear surface of a single layer structure, with an accuracy better than one percent. These measurements are complicated by the presence of thick and/or uneven layers of paint on either the front surface, the back surface, or both. We will discuss progress in overcoming these complications. Examples from both automotive and aircraft structures will be presented.—This material is based in part upon work performed at the FAA Center for Aviation Systems Reliability operated at Iowa State University and supported by the Federal Aviation Administration Technical Center, Atlantic City, New Jersey, under Grant number 95-G-025, and is also supported in part by the Institute for Manufacturing Research, Wayne State University, and by Ford Motor Company. Supported by a Grant from Ford Motor Company.

  9. Total Factor Productivity Growth, Technical Progress & Efficiency Change in Vietnam Coal Industry - Nonparametric Approach

    NASA Astrophysics Data System (ADS)

    Phuong, Vu Hung

    2018-03-01

    This research applies Data Envelopment Analysis (DEA) approach to analyze Total Factor Productivity (TFP) and efficiency changes in Vietnam coal mining industry from 2007 to 2013. The TFP of Vietnam coal mining companies decreased due to slow technological progress and unimproved efficiency. The decadence of technical efficiency in many enterprises proved that the coal mining industry has a large potential to increase productivity through technical efficiency improvement. Enhancing human resource training, technology and research & development investment could help the industry to improve efficiency and productivity in Vietnam coal mining industry.

  10. The Richard C. Schneider Lecture. New dimensions of neurosurgery in the realm of high technology: possibilities, practicalities, realities.

    PubMed

    Apuzzo, M L

    1996-04-01

    Fueled by a buoyant economy, popular attitudes and demands, and parallel progress in transferable technical and biological areas, neurosurgery has enjoyed a remarkable quarter of a century of progress. Developmental trends in the discipline have included the following: 1) a refinement of preoperative definition of the structural substrate, 2) miniaturization of operative corridors, 3) reduction of operative trauma, 4) increased effectiveness at the target site, and 5) incorporation of improved technical adjuvants and physical operative tools into treatment protocols. In particular, the computer has become a formidable ally in diagnostic and surgical events. Trends in technical development indicate that we are entering an exciting era of advanced surgery of the human cerebrum, which is heralded by the following: 1) current developments in areas of imaging, sensors, and visualization; 2) new devices for localization and navigation; 3) new capabilities for action at the target point; and 4) innovative concepts related to advanced operative venues. Imaging has provided structurally based surgical maps, which now are being given the new dimension of function in complex and integrated formats for preoperative planning and intraoperative tactical direction. Cerebral localization and navigation based on these advances promise to provide further refinement to the field of stereotactic neurosurgery, as linked systems are superseded by more flexible nonlinked methodologies in functionally defined volume-oriented navigational databases. Target point action now includes not only ablative capabilities through micro-operative methods and the use of stereotactically directed high-energy forms but also the emergence of restorative capabilities through applications of principles of genetic engineering in the areas of molecular and cellular neurosurgery. Complex, dedicated, and self-contained operative venues will be required to optimize the emergence and development of these computer-oriented micro/stereotactic capabilities, which appear to be unavoidably required as locales for the practice and development of virtual reality-based stations for operative rehearsal, simulation, training, and, ultimately, enhancement of operative events through robotic interfaces. Primary impetus for progress has relied upon new combinations of technologies, disciplines, and industries. Philosophical and practical problems include the spectrum of availability of these methods to the population at large, the training of individuals to properly administer these methods, defining the acceptable envelope of expertise, and maintaining suitable delivery and progress while containing spiraling costs. Advanced neurological surgery and the use and development of high-technology adjuvants require a robust economy that has a populace willing to invest in the luxury of such developments. The current socioeconomic situation is fragile from the standpoint of both economics and attitudes of the patients and health care providers, with diversion of economic resources, redistribution of funding bases, modification of patient referrals, practice styles, and service attitudes undermining progress. Economic pressures have brought high-technology methods under great scrutiny regarding their effectiveness and cost-effectiveness. Reform proposals have specifically targeted technology-oriented services, and the Office of Technology Assessment has recommended increasing the use of managed care providers who look to information on cost-effectiveness and clinical practice guidelines to establish efficient management strategies and issue "report cards." Although the premise is laudable and "gimmickry" needs to be identified, it might be argued that such scrutiny and control might be overbearing and overused, impeding appropriate delivery and progress.

  11. Quantitative Medical Image Analysis for Clinical Development of Therapeutics

    NASA Astrophysics Data System (ADS)

    Analoui, Mostafa

    There has been significant progress in development of therapeutics for prevention and management of several disease areas in recent years, leading to increased average life expectancy, as well as of quality of life, globally. However, due to complexity of addressing a number of medical needs and financial burden of development of new class of therapeutics, there is a need for better tools for decision making and validation of efficacy and safety of new compounds. Numerous biological markers (biomarkers) have been proposed either as adjunct to current clinical endpoints or as surrogates. Imaging biomarkers are among rapidly increasing biomarkers, being examined to expedite effective and rational drug development. Clinical imaging often involves a complex set of multi-modality data sets that require rapid and objective analysis, independent of reviewer's bias and training. In this chapter, an overview of imaging biomarkers for drug development is offered, along with challenges that necessitate quantitative and objective image analysis. Examples of automated and semi-automated analysis approaches are provided, along with technical review of such methods. These examples include the use of 3D MRI for osteoarthritis, ultrasound vascular imaging, and dynamic contrast enhanced MRI for oncology. Additionally, a brief overview of regulatory requirements is discussed. In conclusion, this chapter highlights key challenges and future directions in this area.

  12. Parallel Algorithms for Image Analysis.

    DTIC Science & Technology

    1982-06-01

    8217 _ _ _ _ _ _ _ 4. TITLE (aid Subtitle) S. TYPE OF REPORT & PERIOD COVERED PARALLEL ALGORITHMS FOR IMAGE ANALYSIS TECHNICAL 6. PERFORMING O4G. REPORT NUMBER TR-1180...Continue on reverse side it neceesary aid Identlfy by block number) Image processing; image analysis ; parallel processing; cellular computers. 20... IMAGE ANALYSIS TECHNICAL 6. PERFORMING ONG. REPORT NUMBER TR-1180 - 7. AUTHOR(&) S. CONTRACT OR GRANT NUMBER(s) Azriel Rosenfeld AFOSR-77-3271 9

  13. Image formation in diffusion MRI: A review of recent technical developments

    PubMed Central

    Miller, Karla L.

    2017-01-01

    Diffusion magnetic resonance imaging (MRI) is a standard imaging tool in clinical neurology, and is becoming increasingly important for neuroscience studies due to its ability to depict complex neuroanatomy (eg, white matter connectivity). Single‐shot echo‐planar imaging is currently the predominant formation method for diffusion MRI, but suffers from blurring, distortion, and low spatial resolution. A number of methods have been proposed to address these limitations and improve diffusion MRI acquisition. Here, the recent technical developments for image formation in diffusion MRI are reviewed. We discuss three areas of advance in diffusion MRI: improving image fidelity, accelerating acquisition, and increasing the signal‐to‐noise ratio. Level of Evidence: 5 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:646–662 PMID:28194821

  14. 48 CFR 2011.104-70 - NRC Clauses.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Technical Reports, when deliverables include a technical report. (b) The contracting officer shall insert the clause at 2052.211-71 Technical Progress Report, in all solicitations and contracts except— (1...) The contracting officer shall insert the clause at 2052.211-72 Financial Status Report, in applicable...

  15. 48 CFR 2011.104-70 - NRC Clauses.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Technical Reports, when deliverables include a technical report. (b) The contracting officer shall insert the clause at 2052.211-71 Technical Progress Report, in all solicitations and contracts except— (1...) The contracting officer shall insert the clause at 2052.211-72 Financial Status Report, in applicable...

  16. 48 CFR 2011.104-70 - NRC Clauses.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Technical Reports, when deliverables include a technical report. (b) The contracting officer shall insert the clause at 2052.211-71 Technical Progress Report, in all solicitations and contracts except— (1...) The contracting officer shall insert the clause at 2052.211-72 Financial Status Report, in applicable...

  17. 48 CFR 2011.104-70 - NRC Clauses.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Technical Reports, when deliverables include a technical report. (b) The contracting officer shall insert the clause at 2052.211-71 Technical Progress Report, in all solicitations and contracts except— (1...) The contracting officer shall insert the clause at 2052.211-72 Financial Status Report, in applicable...

  18. 48 CFR 2011.104-70 - NRC Clauses.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Technical Reports, when deliverables include a technical report. (b) The contracting officer shall insert the clause at 2052.211-71 Technical Progress Report, in all solicitations and contracts except— (1...) The contracting officer shall insert the clause at 2052.211-72 Financial Status Report, in applicable...

  19. 32 CFR 203.17 - Technical assistance provider reporting requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 2 2010-07-01 2010-07-01 false Technical assistance provider reporting requirements. 203.17 Section 203.17 National Defense Department of Defense (Continued) OFFICE OF THE SECRETARY... technical assistance provider shall submit progress reports, financial status reports, materials prepared...

  20. 32 CFR 203.17 - Technical assistance provider reporting requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 2 2014-07-01 2014-07-01 false Technical assistance provider reporting requirements. 203.17 Section 203.17 National Defense Department of Defense (Continued) OFFICE OF THE SECRETARY... technical assistance provider shall submit progress reports, financial status reports, materials prepared...

  1. 32 CFR 203.17 - Technical assistance provider reporting requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 2 2013-07-01 2013-07-01 false Technical assistance provider reporting requirements. 203.17 Section 203.17 National Defense Department of Defense (Continued) OFFICE OF THE SECRETARY... technical assistance provider shall submit progress reports, financial status reports, materials prepared...

  2. 32 CFR 203.17 - Technical assistance provider reporting requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 2 2011-07-01 2011-07-01 false Technical assistance provider reporting requirements. 203.17 Section 203.17 National Defense Department of Defense (Continued) OFFICE OF THE SECRETARY... technical assistance provider shall submit progress reports, financial status reports, materials prepared...

  3. 32 CFR 203.17 - Technical assistance provider reporting requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 2 2012-07-01 2012-07-01 false Technical assistance provider reporting requirements. 203.17 Section 203.17 National Defense Department of Defense (Continued) OFFICE OF THE SECRETARY... technical assistance provider shall submit progress reports, financial status reports, materials prepared...

  4. Recent developments in spectroscopic imaging techniques for historical paintings - A review

    NASA Astrophysics Data System (ADS)

    Alfeld, M.; de Viguerie, L.

    2017-10-01

    This paper provides an overview over the application of scanning macro-XRF with mobile instruments for the investigation of historical paintings. The method is compared to synchrotron based macro-XRF imaging and Neutron Activation Auto-Radiography. Full-Field XRF imaging instruments, a potential future alternative to scanning macro-XRF, and confocal XRF, providing complementary depth profiles and developing into a 3D imaging technique itself, are described with the focus on investigations of historical paintings. Recent developments of X-ray radiography are presented and the investigation of cultural heritage objects other than paintings by MA-XRF is summarized. In parallel to XRF, hyperspectral imaging in the visible and range has developed into a technique with comparable capabilities, providing insight in chemical compounds, where XRF imaging identifies the distribution of elements. Due to the complementary nature of these techniques the latter is summarized. Further, progress and state of the art in data evaluation for spectroscopic imaging is discussed. In general it could be observed that technical capabilities in MA-XRF and hyperspectral imaging have reached a plateau and that with the availability of commercial instruments the focus of recent studies has shifted from the development of methods to applications of the instruments. Further, that while simple instruments are easily available with medium budgets only few groups have high-end instrumentation available, bought or in-house built.

  5. ISABELLE: a progress report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hahn, H

    This paper discusses the ISABELLE project, which has the objective of constructing a high-energy proton colliding beam facility at Brookhaven National Laboratory. The major technical features of the intersecting storage accelerators with their projected performance are described. Application of over 1000 superconducting magnets in the two rings represents the salient characteristic of the machine. The status of the entire project, the technical progress made so far, and difficulties encountered are reviewed.

  6. Final Technical Progress Report: Development of Low-Cost Suspension Heliostat; December 7, 2011 - December 6, 2012

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bender, W.

    2013-01-01

    Final technical progress report of SunShot Incubator Solaflect Energy. The project succeeded in demonstrating that the Solaflect Suspension Heliostat design is viable for large-scale CSP installations. Canting accuracy is acceptable and is continually improving as Solaflect improves its understanding of this design. Cost reduction initiatives were successful, and there are still many opportunities for further development and further cost reduction.

  7. Measurement of solids motion in gas-fluidized beds. Technical progress report, 1 October 1982-31 December 1982

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, M.M.; Chao, B.T.

    This technical progress report covers the progress made during the fifth quarter of the project entitled Measurements of Solids Motion in Gas Fluidized Beds under Grant No. DOE-F22-81PC40804 during the period 1 October through 31 December 1982. The research concerns the measurement of solids particle velocity distribution and residence time distribution using the Computer-Aided Particle Tracking Facility (CAPTF) at the University of Illinois at Urbana-Champaign. The experimental equipment and measuring methods used to determine particle size distribution and particle motion and the results obtained are presented.

  8. The 1996 NAEP Technical Report.

    ERIC Educational Resources Information Center

    Allen, Nancy L.; Carlson, James E.; Zelenak, Christine A.

    This report documents the design, administration, and data analysis procedure of the National Assessment of Education Progress (NAEP) for 1996. It indicates the technical decisions that were made and the rationale behind them. Detailed substantive findings are not presented in this report. These chapters provide technical information about the…

  9. Using Satellite Images for Wireless Network Planing in Baku City

    NASA Astrophysics Data System (ADS)

    Gojamanov, M.; Ismayilov, J.

    2013-04-01

    It is a well known fact that the Information-Telecommunication and Space research technologies are the fields getting much more benefits from the achievements of the scientific and technical progress. In many cases, these areas supporting each other have improved the conditions for their further development. For instance, the intensive development in the field of the mobile communication has caused the rapid progress of the Space research technologies and vice versa.Today it is impossible to solve one of the most important tasks of the mobile communication as Radio Frecance planning without the 2D and 3D digital maps. The compiling of such maps is much more efficient by means of the space images. Because the quality of the space images has been improved and developed, especially at the both spectral and spatial resolution points. It has been possible to to use 8 Band images with the spatial resolution of 50 sm. At present, in relation to the function 3G of mobile communications one of the main issues facing mobile operator companies is a high-precision 3D digital maps. It should be noted that the number of mobile phone users in the Republic of Azerbaijan went forward other Community of Independent States Countries. Of course, using of aerial images for 3D mapping would be optimal. However, depending on a number of technical and administrative problems aerial photography cannot be used. Therefore, the experience of many countries shows that it will be more effective to use the space images with the higher resolution for these issues. Concerning the fact that the mobile communication within the city of Baku has included 3G function there were ordered stereo images wih the spatial resolution of 50 cm for the 150 sq.km territory occupying the central part of the city in order to compile 3D digital maps. The images collected from the WorldView-2 satellite are 4-Band Bundle(Pan+MS1) stereo images. Such kind of imagery enable to automatically classificate some required clutter classes.Meanwhile, there were created 12 GPS points in the territory and there have been held some appropriate observations in these points for the geodesic reference of the space images in the territory. Moreover, it would like to mention that there have been constructed 37 permanently acting GPS stations in the territory of Azerbaijan at present. It significantly facilitates the process of the geodesic reference of the space images in order to accomplish such kind of mentioned projects. The processing of the collected space images was accomplished by means of Erdas LPS 10 program. In the first stage there was created the main component of the 3D maps- Digital Elevevation Model. In this model the following clutter classes are presented: Open; Open areas in urban; Airport, Sea, Inland water; Forest; Parks in urban; Semi Open Area; Open Wet Area; Urban/Urban Mean; Dense urban, Villages, Industrial/Commercial, Residential/Suburban; Dense residential/Suburban; Block of BUILDINGS; Dense Urban High; Buildings, Urban Mixed, Mixed dense urban

  10. Genetically Encoded Voltage Indicators: Opportunities and Challenges.

    PubMed

    Yang, Helen H; St-Pierre, François

    2016-09-28

    A longstanding goal in neuroscience is to understand how spatiotemporal patterns of neuronal electrical activity underlie brain function, from sensory representations to decision making. An emerging technology for monitoring electrical dynamics, voltage imaging using genetically encoded voltage indicators (GEVIs), couples the power of genetics with the advantages of light. Here, we review the properties that determine indicator performance and applicability, discussing both recent progress and technical limitations. We then consider GEVI applications, highlighting studies that have already deployed GEVIs for biological discovery. We also examine which classes of biological questions GEVIs are primed to address and which ones are beyond their current capabilities. As GEVIs are further developed, we anticipate that they will become more broadly used by the neuroscience community to eavesdrop on brain activity with unprecedented spatiotemporal resolution. Genetically encoded voltage indicators are engineered light-emitting protein sensors that typically report neuronal voltage dynamics as changes in brightness. In this review, we systematically discuss the current state of this emerging method, considering both its advantages and limitations for imaging neural activity. We also present recent applications of this technology and discuss what is feasible now and what we anticipate will become possible with future indicator development. This review will inform neuroscientists of recent progress in the field and help potential users critically evaluate the suitability of genetically encoded voltage indicator imaging to answer their specific biological questions. Copyright © 2016 the authors 0270-6474/16/369977-13$15.00/0.

  11. Use magnetic resonance imaging to assess articular cartilage

    PubMed Central

    Wang, Yuanyuan; Wluka, Anita E.; Jones, Graeme; Ding, Changhai

    2012-01-01

    Magnetic resonance imaging (MRI) enables a noninvasive, three-dimensional assessment of the entire joint, simultaneously allowing the direct visualization of articular cartilage. Thus, MRI has become the imaging modality of choice in both clinical and research settings of musculoskeletal diseases, particular for osteoarthritis (OA). Although radiography, the current gold standard for the assessment of OA, has had recent significant technical advances, radiographic methods have significant limitations when used to measure disease progression. MRI allows accurate and reliable assessment of articular cartilage which is sensitive to change, providing the opportunity to better examine and understand preclinical and very subtle early abnormalities in articular cartilage, prior to the onset of radiographic disease. MRI enables quantitative (cartilage volume and thickness) and semiquantitative assessment of articular cartilage morphology, and quantitative assessment of cartilage matrix composition. Cartilage volume and defects have demonstrated adequate validity, accuracy, reliability and sensitivity to change. They are correlated to radiographic changes and clinical outcomes such as pain and joint replacement. Measures of cartilage matrix composition show promise as they seem to relate to cartilage morphology and symptoms. MRI-derived cartilage measurements provide a useful tool for exploring the effect of modifiable factors on articular cartilage prior to clinical disease and identifying the potential preventive strategies. MRI represents a useful approach to monitoring the natural history of OA and evaluating the effect of therapeutic agents. MRI assessment of articular cartilage has tremendous potential for large-scale epidemiological studies of OA progression, and for clinical trials of treatment response to disease-modifying OA drugs. PMID:22870497

  12. Lincoln County nuclear waste project. Quarterly progress report, October 1, 1991--December 31, 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-03-01

    This document included the following three progress reports to the Yucca Mountain Project Office on radioactive waste storage in Lincoln County, Nevada: financial status report; federal cash transactions report; and technical progress report.

  13. Lincoln County nuclear waste project. Quarterly progress report, January 1, 1992--March 31, 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-03-01

    This document included the following three progress reports to the Yucca Mountain Project Office on radioactive waste storage in Lincoln County, Nevada: financial status report; federal cash transactions report; and technical progress report.

  14. Lincoln County nuclear waste project quarterly progress report, April 1, 1992--June 30, 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-03-01

    This document included the following three progress reports to the Yucca Mountain Project Office on radioactive waste storage in Lincoln County, Nevada: financial status report; federal cash transactions report; and technical progress report.

  15. Functional neuroimaging: technical, logical, and social perspectives.

    PubMed

    Aguirre, Geoffrey K

    2014-01-01

    Neuroscientists have long sought to study the dynamic activity of the human brain-what's happening in the brain, that is, while people are thinking, feeling, and acting. Ideally, an inside look at brain function would simultaneously and continuously measure the biochemical state of every cell in the central nervous system. While such a miraculous method is science fiction, a century of progress in neuroimaging technologies has made such simultaneous and continuous measurement a plausible fiction. Despite this progress, practitioners of modern neuroimaging struggle with two kinds of limitations: those that attend the particular neuroimaging methods we have today and those that would limit any method of imaging neural activity, no matter how powerful. In this essay, I consider the liabilities and potential of techniques that measure human brain activity. I am concerned here only with methods that measure relevant physiologic states of the central nervous system and relate those measures to particular mental states. I will consider in particular the preeminent method of functional neuroimaging: BOLD fMRI. While there are several practical limits on the biological information that current technologies can measure, these limits-as important as they are-are minor in comparison to the fundamental logical restraints on the conclusions that can be drawn from brain imaging studies. © 2014 by The Hastings Center.

  16. First Year of WFIRST/AFTA Coronagraph Technology Development: Testbed Progress Update

    NASA Astrophysics Data System (ADS)

    Poberezhskiy, Ilya; Poberezhskiy, Ilya; Zhao, Feng; An, Xin; Balasubramanian, Kunjithapatham; Belikov, Rus; Cady, Eric; Diaz, Rosemary; Gordon, Brian; Guyon, Olivier; Kasdin, N. Jeremy; Kern, Brian; Kuhnert, Andreas; Moody, Dwight; Muller, Richard; Nemati, Bijan; Patterson, Keith; Riggs, A. J.; Ryan, Daniel; Seo, Byoung-Joon; Sidick, Erkin; Shi, Fang; Tang, Hong; Trauger, John; Wallace, Kent; Wang, Xu; Wilson, Daniel; White, Victor; Yee, Karl; Zhou, Hanying; Zimmerman, Neil

    2015-01-01

    NASA's WFIRST/AFTA mission study includes the first high-contrast stellar coronagraph in space. This coronagraph will be capable of imaging and spectrally characterizing giant exoplanets similar to Neptune and Jupiter and possibly super-Earths, as well as circumstellar disks. After a transparent and rigorous downselect process, NASA chose in December of 2013 a primary design called an Occulting Mask Coronagraph (OMC) that combines two technical approaches, Shaped Pupil and Hybrid Lyot, in one instrument. The Phase-Induced Amplitude Apodization Complex Mask Coronagraph was selected as the backup design.The OMC coronagraph technologies were assessed to have the highest likelihood of passing the WFIRST/AFTA flight readiness gates and the ability to produce compelling science by working with the existing 2.4-meter telescope 'as is,' including its central obscuration, expected thermal drift, and the observatory pointing jitter. NASA set us the objective of maturing the WFIRST/AFTA coronagraph to Technology Readiness Level (TRL) 5 by October 1, 2016. A set of technical milestones was agreed upon to track the progress toward achieving TRL 5.Substantial advances in WFIRST/AFTA coronagraph technology have been made during 2014, and the OMC progress is currently running ahead of the schedule laid out by the milestones. Our poster will present some of these key recent results to the community, including:(1) Fabrication and characterization of WFIRST/AFTA coronagraph pupil plane and focal plane masks designed to work with the existing 2.4 telescope.(2) Experimental results demonstrating high contrast achieved on a coronagraph testbed in narrowband and broadband light - first such results obtained with an obscured pupil.(3) Progress in the development of the low-order wavefront sensing and control subsystem that will use rejected starlight to sense and correct both high frequency pointing jitter and slow varying low order aberrations. This subsystem will be integrated with the OMC coronagraph in mid-2015 for the next phase of starlight suppression experiments with dynamic input wavefront.

  17. Index to Nuclear Safety: a technical progress review by chronology, permuted title, and author, Volume 18 (1) through Volume 22 (6)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cottrell, W.B.; Passiakos, M.

    This index to Nuclear Safety covers articles published in Nuclear Safety, Volume 18, Number 1 (January-February 1977) through Volume 22, Number 6 (November-December 1981). The index is divided into three section: a chronological list of articles (including abstracts), a permuted-title (KWIC) index, and an author index. Nuclear Safety, a bimonthly technical progress review prepared by the Nuclear Safety Information Center, covers all safety aspects of nuclear power reactors and associated facilities. Over 300 technical articles published in Nuclear Safety in the last 5 years are listed in this index.

  18. 77 FR 16250 - Notice of Proposed Information Collection for Public Comment; Office of Native American Programs...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-20

    ... Information Collection for Public Comment; Office of Native American Programs (ONAP) Training and Technical... subject proposal. The data required by Office of Native American Programs Training and Technical... progress. The data identifies needs, outputs and outcomes of the training and technical assistance. DATES...

  19. Fluorescent carbon dots from mono- and polysaccharides: synthesis, properties and applications

    PubMed Central

    Hill, Stephen

    2017-01-01

    Fluorescent carbon dots (FCDs) are an emerging class of nanomaterials made from carbon sources that have been hailed as potential non-toxic replacements to traditional semiconductor quantum dots (QDs). Particularly in the areas of live imaging and drug delivery, due to their water solubility, low toxicity and photo- and chemical stability. Carbohydrates are readily available chiral biomolecules in nature which offer an attractive and cheap starting material from which to synthesise FCDs with distinct features and interesting applications. This mini-review article will cover the progress in the development of FCDs prepared from carbohydrate sources with an emphasis on their synthesis, functionalization and technical applications, including discussions on current challenges. PMID:28503203

  20. Social inequalities in the face of scientific and technological development: an antinomy or an historic problem?

    PubMed

    Delgado, Guilherme Costa

    2017-07-01

    This paper aims to conduct a conceptual analysis of the relationship between scientific and technical progress and social equality, or the reduction of inequalities. We examine this relationship by drawing on three theoretical perspectives: 1) ethical economics, championed by classical economic thinkers and centered on utilitarian self-interest, 2) Mainstream theories of economic development espousing the endogenous link between labor productivity growth and technical progress, 3) the critique of theories of economic development that emerged in the second half of the twentieth century, including Celso Furtado's critique of the theory of underdevelopment, emphasizing the prevalence of egalitarian tendencies, and ecological economics, which suggest alternative paths to those set by "classical" theories of development. The fundamental antinomy posed by the title of this article, characterized by an intrinsic contradiction between technical progress and social equality, strictly presupposes the ethical economics perspective, dominated by the social relations that constitute the "social order".

  1. Spectroscopic scanning tunneling microscopy insights into Fe-based superconductors

    NASA Astrophysics Data System (ADS)

    Hoffman, Jennifer E.

    2011-12-01

    In the first three years since the discovery of Fe-based high Tc superconductors, scanning tunneling microscopy (STM) and spectroscopy have shed light on three important questions. First, STM has demonstrated the complexity of the pairing symmetry in Fe-based materials. Phase-sensitive quasiparticle interference (QPI) imaging and low temperature spectroscopy have shown that the pairing order parameter varies from nodal to nodeless s± within a single family, FeTe1-xSex. Second, STM has imaged C4 → C2 symmetry breaking in the electronic states of both parent and superconducting materials. As a local probe, STM is in a strong position to understand the interactions between these broken symmetry states and superconductivity. Finally, STM has been used to image the vortex state, giving insights into the technical problem of vortex pinning, and the fundamental problem of the competing states introduced when superconductivity is locally quenched by a magnetic field. Here we give a pedagogical introduction to STM and QPI imaging, discuss the specific challenges associated with extracting bulk properties from the study of surfaces, and report on progress made in understanding Fe-based superconductors using STM techniques.

  2. 3-D segmentation of articular cartilages by graph cuts using knee MR images from osteoarthritis initiative

    NASA Astrophysics Data System (ADS)

    Shim, Hackjoon; Lee, Soochan; Kim, Bohyeong; Tao, Cheng; Chang, Samuel; Yun, Il Dong; Lee, Sang Uk; Kwoh, Kent; Bae, Kyongtae

    2008-03-01

    Knee osteoarthritis is the most common debilitating health condition affecting elderly population. MR imaging of the knee is highly sensitive for diagnosis and evaluation of the extent of knee osteoarthritis. Quantitative analysis of the progression of osteoarthritis is commonly based on segmentation and measurement of articular cartilage from knee MR images. Segmentation of the knee articular cartilage, however, is extremely laborious and technically demanding, because the cartilage is of complex geometry and thin and small in size. To improve precision and efficiency of the segmentation of the cartilage, we have applied a semi-automated segmentation method that is based on an s/t graph cut algorithm. The cost function was defined integrating regional and boundary cues. While regional cues can encode any intensity distributions of two regions, "object" (cartilage) and "background" (the rest), boundary cues are based on the intensity differences between neighboring pixels. For three-dimensional (3-D) segmentation, hard constraints are also specified in 3-D way facilitating user interaction. When our proposed semi-automated method was tested on clinical patients' MR images (160 slices, 0.7 mm slice thickness), a considerable amount of segmentation time was saved with improved efficiency, compared to a manual segmentation approach.

  3. Brain tumor classification using AFM in combination with data mining techniques.

    PubMed

    Huml, Marlene; Silye, René; Zauner, Gerald; Hutterer, Stephan; Schilcher, Kurt

    2013-01-01

    Although classification of astrocytic tumors is standardized by the WHO grading system, which is mainly based on microscopy-derived, histomorphological features, there is great interobserver variability. The main causes are thought to be the complexity of morphological details varying from tumor to tumor and from patient to patient, variations in the technical histopathological procedures like staining protocols, and finally the individual experience of the diagnosing pathologist. Thus, to raise astrocytoma grading to a more objective standard, this paper proposes a methodology based on atomic force microscopy (AFM) derived images made from histopathological samples in combination with data mining techniques. By comparing AFM images with corresponding light microscopy images of the same area, the progressive formation of cavities due to cell necrosis was identified as a typical morphological marker for a computer-assisted analysis. Using genetic programming as a tool for feature analysis, a best model was created that achieved 94.74% classification accuracy in distinguishing grade II tumors from grade IV ones. While utilizing modern image analysis techniques, AFM may become an important tool in astrocytic tumor diagnosis. By this way patients suffering from grade II tumors are identified unambiguously, having a less risk for malignant transformation. They would benefit from early adjuvant therapies.

  4. Biomedical Applications of Carbon Nanotubes: A Critical Review.

    PubMed

    Sharma, Priyanka; Mehra, Neelesh Kumar; Jain, Keerti; Jain, N K

    2016-08-01

    The convergence of nano and biotechnology is enabling scientific and technical knowledge for improving human well being. Carbon nanotubes have become most fascinating material to be studied and unveil new avenues in the field of nanobiotechnology. The nanometer size and high aspect ratio of the CNTs are the two distinct features, which have contributed to diverse biomedical applications. They have captured the attention as nanoscale materials due to their nanometric structure and remarkable list of superlative and extravagant properties that encouraged their exploitation for promising applications. Significant progress has been made in order to overcome some of the major hurdles towards biomedical application of nanomaterials, especially on issues regarding the aqueous solubility/dispersion and safety of CNTs. Functionalized CNTs have been used in drug targeting, imaging, and in the efficient delivery of gene and nucleic acids. CNTs have also demonstrated great potential in diverse biomedical uses like drug targeting, imaging, cancer treatment, tissue regeneration, diagnostics, biosensing, genetic engineering and so forth. The present review highlights the possible potential of CNTs in diagnostics, imaging and targeted delivery of bioactives and also outlines the future opportunities for biomedical applications.

  5. Gold nanoparticle contrast agents in advanced X-ray imaging technologies.

    PubMed

    Ahn, Sungsook; Jung, Sung Yong; Lee, Sang Joon

    2013-05-17

    Recently, there has been significant progress in the field of soft- and hard-X-ray imaging for a wide range of applications, both technically and scientifically, via developments in sources, optics and imaging methodologies. While one community is pursuing extensive applications of available X-ray tools, others are investigating improvements in techniques, including new optics, higher spatial resolutions and brighter compact sources. For increased image quality and more exquisite investigation on characteristic biological phenomena, contrast agents have been employed extensively in imaging technologies. Heavy metal nanoparticles are excellent absorbers of X-rays and can offer excellent improvements in medical diagnosis and X-ray imaging. In this context, the role of gold (Au) is important for advanced X-ray imaging applications. Au has a long-history in a wide range of medical applications and exhibits characteristic interactions with X-rays. Therefore, Au can offer a particular advantage as a tracer and a contrast enhancer in X-ray imaging technologies by sensing the variation in X-ray attenuation in a given sample volume. This review summarizes basic understanding on X-ray imaging from device set-up to technologies. Then this review covers recent studies in the development of X-ray imaging techniques utilizing gold nanoparticles (AuNPs) and their relevant applications, including two- and three-dimensional biological imaging, dynamical processes in a living system, single cell-based imaging and quantitative analysis of circulatory systems and so on. In addition to conventional medical applications, various novel research areas have been developed and are expected to be further developed through AuNP-based X-ray imaging technologies.

  6. Systematic literature review of digital three-dimensional superimposition techniques to create virtual dental patients.

    PubMed

    Joda, Tim; Brägger, Urs; Gallucci, German

    2015-01-01

    Digital developments have led to the opportunity to compose simulated patient models based on three-dimensional (3D) skeletal, facial, and dental imaging. The aim of this systematic review is to provide an update on the current knowledge, to report on the technical progress in the field of 3D virtual patient science, and to identify further research needs to accomplish clinical translation. Searches were performed electronically (MEDLINE and OVID) and manually up to March 2014 for studies of 3D fusion imaging to create a virtual dental patient. Inclusion criteria were limited to human studies reporting on the technical protocol for superimposition of at least two different 3D data sets and medical field of interest. Of the 403 titles originally retrieved, 51 abstracts and, subsequently, 21 full texts were selected for review. Of the 21 full texts, 18 studies were included in the systematic review. Most of the investigations were designed as feasibility studies. Three different types of 3D data were identified for simulation: facial skeleton, extraoral soft tissue, and dentition. A total of 112 patients were investigated in the development of 3D virtual models. Superimposition of data on the facial skeleton, soft tissue, and/or dentition is a feasible technique to create a virtual patient under static conditions. Three-dimensional image fusion is of interest and importance in all fields of dental medicine. Future research should focus on the real-time replication of a human head, including dynamic movements, capturing data in a single step.

  7. Metrology Standards for Quantitative Imaging Biomarkers

    PubMed Central

    Obuchowski, Nancy A.; Kessler, Larry G.; Raunig, David L.; Gatsonis, Constantine; Huang, Erich P.; Kondratovich, Marina; McShane, Lisa M.; Reeves, Anthony P.; Barboriak, Daniel P.; Guimaraes, Alexander R.; Wahl, Richard L.

    2015-01-01

    Although investigators in the imaging community have been active in developing and evaluating quantitative imaging biomarkers (QIBs), the development and implementation of QIBs have been hampered by the inconsistent or incorrect use of terminology or methods for technical performance and statistical concepts. Technical performance is an assessment of how a test performs in reference objects or subjects under controlled conditions. In this article, some of the relevant statistical concepts are reviewed, methods that can be used for evaluating and comparing QIBs are described, and some of the technical performance issues related to imaging biomarkers are discussed. More consistent and correct use of terminology and study design principles will improve clinical research, advance regulatory science, and foster better care for patients who undergo imaging studies. © RSNA, 2015 PMID:26267831

  8. Cardiovascular Optical Coherence Tomography

    NASA Astrophysics Data System (ADS)

    Yonetsu, Taishi; Villiger, Martin; Bouma, Brett E.; Jang, Ik-Kyung

    The potential of optical coherence tomography (OCT) for intravascular imaging and assessing the microstructure of atherosclerosis was suggested already by Huang et al. at the very beginning of OCT [1]. For ophthalmology, the eye provides a natural window for OCT to image the retinal microstructure, and OCT has rapidly become the standard imaging modality to diagnose retinal disease and assess disease progression and response to therapy [1, 2]. Intravascular imaging is more invasive by nature and requires imaging through a catheter probe. This has triggered the development of advanced fiber-optic OCT systems with compact, rotating fiber probes, to image the vessel by circumferentially scanning the luminal wall [3, 4]. In 1998, we established the first cardiac OCT research group at the Massachusetts General Hospital to explore the clinical applications of OCT. The first imaging of rabbit aorta was reported by Fujimoto et al. [5], followed by the first swine measurements in vivo by Tearney et al. [6], and finally the first assessment of coronary arteries in patients by Jang et al. [7]. The scope of this chapter is to highlight the steps taken to bring intravascular OCT from bench to bedside over the last 15 years. We will give a general description of atherosclerosis and its pathophysiology and the specific technical implementation of OCT for intravascular imaging through a fiber-optic probe. The motivation is to provide sufficient medical details to provide a basic introduction to the terminology, principles, and challenges of intracoronary imaging.

  9. Principles of PET/MR Imaging.

    PubMed

    Disselhorst, Jonathan A; Bezrukov, Ilja; Kolb, Armin; Parl, Christoph; Pichler, Bernd J

    2014-06-01

    Hybrid PET/MR systems have rapidly progressed from the prototype stage to systems that are increasingly being used in the clinics. This review provides an overview of developments in hybrid PET/MR systems and summarizes the current state of the art in PET/MR instrumentation, correction techniques, and data analysis. The strong magnetic field requires considerable changes in the manner by which PET images are acquired and has led, among others, to the development of new PET detectors, such as silicon photomultipliers. During more than a decade of active PET/MR development, several system designs have been described. The technical background of combined PET/MR systems is explained and related challenges are discussed. The necessity for PET attenuation correction required new methods based on MR data. Therefore, an overview of recent developments in this field is provided. Furthermore, MR-based motion correction techniques for PET are discussed, as integrated PET/MR systems provide a platform for measuring motion with high temporal resolution without additional instrumentation. The MR component in PET/MR systems can provide functional information about disease processes or brain function alongside anatomic images. Against this background, we point out new opportunities for data analysis in this new field of multimodal molecular imaging. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  10. Developments in Technical Education in the British Caribbean, 1940-60.

    ERIC Educational Resources Information Center

    Pemberton, S. Macpherson

    The paper discusses developments in technical education in the British West Indies from 1940-1960 emphasizing the relation between education and economic development. The objective is to analyze the economic basis of progress in technical education. The document is presented in four chapters. Chapter I summarizes historical background prior to…

  11. Programs of Study: Year 2 Joint Technical Report. Research Snapshot

    ERIC Educational Resources Information Center

    National Research Center for Career and Technical Education, 2010

    2010-01-01

    In January 2010, the National Research Center for Career and Technical Education (NRCCTE) issued a progress report on three studies being conducted by the Center that examine the implementation and outcomes of Programs of Study (POS), which were required in the 2006 reauthorization of the federal legislation for career and technical education…

  12. Terminology and reporting criteria for radiofrequency ablation of tumors in the scientific literature: systematic review of compliance with reporting standards.

    PubMed

    Kang, Tae Wook; Rhim, Hyunchul; Lee, Min Woo; Kim, Young-sun; Choi, Dongil; Lim, Hyo Keun

    2014-01-01

    To perform a systematic review of compliance with standardized terminology and reporting criteria for radiofrequency (RF) tumor ablation, proposed by the International Working Group on Image-Guided Tumor Ablation in 2003, in the published reports. Literature search in the PubMed database was performed using index keywords, PubMed limit system, and eligibility criteria. The entire content of each article was reviewed to assess the terminology used for procedure terms, imaging findings, therapeutic efficacy, follow-up, and complications. Accuracy of the terminology and the use of alternative terms instead of standard terminology were analyzed. In addition, disparities in accuracy of terminology in articles according to the medical specialty and the type of radiology journal were evaluated. Among the articles (n = 308) included in this study, the accuracy of the terms 'procedure or session', 'treatment', 'index tumor', 'ablation zone', 'technical success', 'primary technique effectiveness rate', 'secondary technique effectiveness rate', 'local tumor progression', 'major complication', and 'minor complication' was 97% (298/307), 97% (291/300), 8% (25/307), 65% (103/159), 55% (52/94), 33% (42/129), 94% (17/18), 45% (88/195), 99% (79/80), and 100% (77/77), respectively. The overall accuracy of each term showed a tendency to improve over the years. The most commonly used alternative terms for 'technical success' and 'local tumor progression' were 'complete ablation' and 'local (tumor) recurrence', respectively. The accuracy of terminology in articles published in radiology journals was significantly greater than that of terminology in articles published in non-radiology journals, especially in Radiology and The Journal of Vascular and Interventional Radiology. The proposal for standardization of terminology and reporting criteria for RF tumor ablation has been gaining support according to the recently published scientific reports, especially in the field of radiology. However, more work is still needed for the complete standardization of terminology.

  13. Terminology and Reporting Criteria for Radiofrequency Ablation of Tumors in the Scientific Literature: Systematic Review of Compliance with Reporting Standards

    PubMed Central

    Kang, Tae Wook; Lee, Min Woo; Kim, Young-sun; Choi, Dongil; Lim, Hyo Keun

    2014-01-01

    Objective To perform a systematic review of compliance with standardized terminology and reporting criteria for radiofrequency (RF) tumor ablation, proposed by the International Working Group on Image-Guided Tumor Ablation in 2003, in the published reports. Materials and Methods Literature search in the PubMed database was performed using index keywords, PubMed limit system, and eligibility criteria. The entire content of each article was reviewed to assess the terminology used for procedure terms, imaging findings, therapeutic efficacy, follow-up, and complications. Accuracy of the terminology and the use of alternative terms instead of standard terminology were analyzed. In addition, disparities in accuracy of terminology in articles according to the medical specialty and the type of radiology journal were evaluated. Results Among the articles (n = 308) included in this study, the accuracy of the terms 'procedure or session', 'treatment', 'index tumor', 'ablation zone', 'technical success', 'primary technique effectiveness rate', 'secondary technique effectiveness rate', 'local tumor progression', 'major complication', and 'minor complication' was 97% (298/307), 97% (291/300), 8% (25/307), 65% (103/159), 55% (52/94), 33% (42/129), 94% (17/18), 45% (88/195), 99% (79/80), and 100% (77/77), respectively. The overall accuracy of each term showed a tendency to improve over the years. The most commonly used alternative terms for 'technical success' and 'local tumor progression' were 'complete ablation' and 'local (tumor) recurrence', respectively. The accuracy of terminology in articles published in radiology journals was significantly greater than that of terminology in articles published in non-radiology journals, especially in Radiology and The Journal of Vascular and Interventional Radiology. Conclusion The proposal for standardization of terminology and reporting criteria for RF tumor ablation has been gaining support according to the recently published scientific reports, especially in the field of radiology. However, more work is still needed for the complete standardization of terminology. PMID:24497798

  14. Inexpensive, Near-Infrared Imaging of Artwork Using a Night-Vision Webcam for Chemistry-of-Art Courses

    ERIC Educational Resources Information Center

    Smith, Gregory D.; Nunan, Elizabeth; Walker, Claire; Kushel, Dan

    2009-01-01

    Imaging of artwork is an important aspect of art conservation, technical art history, and art authentication. Many forms of near-infrared (NIR) imaging are used by conservators, archaeologists, forensic scientists, and technical art historians to examine the underdrawings of paintings, to detect damages and restorations, to enhance faded or…

  15. Proceedings: Computer Science and Data Systems Technical Symposium, volume 1

    NASA Technical Reports Server (NTRS)

    Larsen, Ronald L.; Wallgren, Kenneth

    1985-01-01

    Progress reports and technical updates of programs being performed by NASA centers are covered. Presentations in viewgraph form are included for topics in three categories: computer science, data systems and space station applications.

  16. The value of digital imaging in diabetic retinopathy.

    PubMed

    Sharp, P F; Olson, J; Strachan, F; Hipwell, J; Ludbrook, A; O'Donnell, M; Wallace, S; Goatman, K; Grant, A; Waugh, N; McHardy, K; Forrester, J V

    2003-01-01

    To assess the performance of digital imaging, compared with other modalities, in screening for and monitoring the development of diabetic retinopathy. All imaging was acquired at a hospital assessment clinic. Subsequently, study optometrists examined the patients in their own premises. A subset of patients also had fluorescein angiography performed every 6 months. Research clinic at the hospital eye clinic and optometrists' own premises. Study comprised 103 patients who had type 1 diabetes mellitus, 481 had type 2 diabetes mellitus and two had secondary diabetes mellitus; 157 (26.8%) had some form of retinopathy ('any') and 58 (9.9%) had referable retinopathy. A repeat assessment was carried out of all patients 1 year after their initial assessment. Patients who had more severe forms of retinopathy were monitored more frequently for evidence of progression. Detection of retinopathy, progression of retinopathy and determination of when treatment is required. Manual grading of 35-mm colour slides produced the highest sensitivity and specificity figures, with optometrist examination recording most false negatives. Manual and automated analysis of digital images had intermediate sensitivity. Both manual grading of 35-mm colour slides and digital images gave sensitivities of over 90% with few false positives. Digital imaging produced 50% fewer ungradable images than colour slides. This part of the study was limited as patients with the more severe levels of retinopathy opted for treatment. There was an increase in the number of microaneurysms in those patients who developed from mild to moderate. There was no difference between the turnover rate of either new or regressed microaneurysms for patients with mild or with sight-threatening retinopathy. It was not possible in this study to ascertain whether digital imaging systems determine when treatment is warranted. In the context of a national screening programme for referable retinopathy, digital imaging is an effective method. In addition, technical failure rates are lower with digital imaging than conventional photography. Digital imaging is also a more sensitive technique than slit-lamp examination by optometrists. Automated grading can improve efficiency by correctly identifying just under half the population as having no retinopathy. Recommendations for future research include: investigating whether the nasal field is required for grading; a large screening programme is required to ascertain if automated grading can safely perform as a first-level grader; if colour improves the performance of grading digital images; investigating methods to ensure effective uptake in a diabetic retinopathy screening programme.

  17. An image, looking east into Room 112A, filled with technical ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    An image, looking east into Room 112A, filled with technical equipment pertinent to the building's recent use - Department of Energy, Mound Facility, Electronics Laboratory Building (E Building), One Mound Road, Miamisburg, Montgomery County, OH

  18. Technical progress in silicon sheet growth under DOE/JPL FSA program, 1975-1986

    NASA Technical Reports Server (NTRS)

    Kalejs, J. P.

    1986-01-01

    The technical progress made in the Silicon Sheet Growth Program during its 11 years was reviewed. At present, in 1986, only two of the original 9 techniques have survived to the start-up, pilot-plant stage in industry. These two techniques are the edge-defined, film-fed growth (EFG) technique that produces closed shape polygons, and the WEB dendritic technique that produces single ribbons. Both the status and future concerns of the EFG and WEB techniques were discussed.

  19. Annual Progress Report (17th) and 1992-97 Renewal Proposal Interactive Graphics for Molecular Studies

    DTIC Science & Technology

    1991-01-24

    Molecular Graphics, vol. 6, No. 4 (Dec. 1988), p. 223. Turk, Greg, "Interactive Collision Detection for Molecular Graphics," M.S. thesis , UNC-Chapel Hill...Problem," Master’s thesis , UNC Department of Computer Science Technical Report #TR87-013, May 1987. Pique, ME., "Technical Trends in Molecular Graphics...AD-A236 598 Seventeenth Annual Progress Report and 1992-97 Renewal Proposal Interactive Graphics for Molecular Studies TR91-020 January 24, 1991 red

  20. Enhanced oil recovery utilizing high-angle wells in the Frontier Formation, Badger Basin Field, Park County, Wyoming. Quarterly technical progress report, 1 March 1993--30 June 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fortmann, R.G.; Walker, J.P.

    1993-07-10

    Sierra Energy Company`s targeted goals during the third quarter of this Cooperative Agreement included the following objectives from the Statement of Work: in Phase 2A, completion of subtask 2.1.2--acquire best possible field data in the 3-D seismic program; and initiation of Subtask 2.1.3--process acquired 3-D seismic data. Technical progress is described for these tasks.

  1. 10 CFR 603.1100 - Contracting officer's post-award responsibilities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... technical progress, financial status, and future program plans. (b) Tracking and processing of reports... progress reports, and patent reports. (c) Handling payment requests and related matters. For a TIA using advance payments, that includes reviews of progress to verify that there is continued justification for...

  2. 7 CFR 3402.23 - Documentation of progress on funded projects.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... the academic program due to unsatisfactory academic progress; or voluntarily withdraws from the Fellowship or the academic program. If a Fellow has not completed all degree requirements at the end of the... database contains narrative project information, progress/impact statements, and final technical reports...

  3. 7 CFR 3402.23 - Documentation of progress on funded projects.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the academic program due to unsatisfactory academic progress; or voluntarily withdraws from the Fellowship or the academic program. If a Fellow has not completed all degree requirements at the end of the... database contains narrative project information, progress/impact statements, and final technical reports...

  4. 7 CFR 3402.23 - Documentation of progress on funded projects.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... the academic program due to unsatisfactory academic progress; or voluntarily withdraws from the Fellowship or the academic program. If a Fellow has not completed all degree requirements at the end of the... database contains narrative project information, progress/impact statements, and final technical reports...

  5. 7 CFR 3402.23 - Documentation of progress on funded projects.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... the academic program due to unsatisfactory academic progress; or voluntarily withdraws from the Fellowship or the academic program. If a Fellow has not completed all degree requirements at the end of the... database contains narrative project information, progress/impact statements, and final technical reports...

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baere, Thierry de, E-mail: thierry.debaere@gustaveroussy.fr; Arai, Yasuaki, E-mail: arai-y3111@mvh.biglobe.ne.jp; Lencioni, Riccardo, E-mail: riccardo.lencioni@med.unipi.it

    Transarterial chemoembolization with Lipiodol (Lipiodol TACE), also called conventional TACE, was developed in the early 1980s and widely adopted worldwide after randomized control trials and meta-analysis demonstrated superiority of Lipiodol TACE to best supportive care. Presently, there is no level one evidence that other TACE techniques are superior to Lipiodol TACE for intermediate stage hepatocellular carcinoma (HCC), which includes patients with preserved liver function and nonsurgical large or multinodular HCC without distant metastases. In addition, TACE is part of the treatment for progressive or symptomatic liver metastases from gastroenteropancreatic neuroendocrine tumors. When injected into the hepatic artery, Lipiodol has themore » unique property of selective uptake and retention in hyperarterialyzed liver tumors. Lipiodol/drug emulsion followed by particle embolization has been demonstrated to improve the pharmacokinetic of the drug and tumor response. Radio opacity of Lipiodol helps to monitor treatment delivery, with retention of Lipiodol serving as an imaging biomarker for tumor response. For 30 years, Lipiodol TACE has been inconsistently referenced in many publications with various levels of details for the method of preparation and administration, with reported progressive outcomes following improvements in the technique and the devices used to deliver the treatment and better patient selection. Consequently, there is no consensus on the standard method of TACE regarding the use of anticancer agents, embolic material, technical details, and the treatment schedule. In order to develop an internationally validated technical recommendation to standardize the Lipiodol TACE procedure, a worldwide panel of experts participated in a consensus meeting held on May 10, 2014.« less

  7. NAEP 1999 Long-Term Trend Technical Analysis Report: Three Decades of Student Performance. NCES 2005-484

    ERIC Educational Resources Information Center

    Allen, Nancy L.; McClellan, Catherine A.; Stoeckel, Joan J.

    2005-01-01

    This report provides an update to the technical analysis procedures documenting the 1996 National Assessment of Educational Progress (NAEP) as presented in "The NAEP 1996 Technical Report" (Allen, Carlson, and Zelenak, 1999). It describes how the 1999 long-term trend data were incorporated into the trend analyses. Since no national main…

  8. Combining image-processing and image compression schemes

    NASA Technical Reports Server (NTRS)

    Greenspan, H.; Lee, M.-C.

    1995-01-01

    An investigation into the combining of image-processing schemes, specifically an image enhancement scheme, with existing compression schemes is discussed. Results are presented on the pyramid coding scheme, the subband coding scheme, and progressive transmission. Encouraging results are demonstrated for the combination of image enhancement and pyramid image coding schemes, especially at low bit rates. Adding the enhancement scheme to progressive image transmission allows enhanced visual perception at low resolutions. In addition, further progressing of the transmitted images, such as edge detection schemes, can gain from the added image resolution via the enhancement.

  9. Technologies for diagnosis and treatment of acute stroke

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fitch, J.P.

    1998-02-09

    From October 1994 to June 1997, a multidisciplinary team of scientists and engineers at Lawrence Livermore National Laboratory were funded through LDRD to develop and integrate technologies for diagnosis and treatment of acute stroke. The project was summarized in a Science and Technology Review article `Brain Attack` that appeared in June 1997 and again in the Center for Healthcare Technologies Report (UCRL-LR-124761). This article is the best overview of the project, epidemiology of stroke and technical progress. Most of the technical progress has been documented in conference papers and presentations and refereed journal articles. Additional technical publication can be expectedmore » as our remaining patent applications progress through the US Patent and Trademark Office. The purpose of this report is to provide an appropriate introduction and organization to the numerous publications so that interested readers can quickly find information. Because there is no documentation for the history of this project, this report provides a summary. It also provides the final status report for the LDRD funding.« less

  10. A CAD Approach to Integrating NDE With Finite Element

    NASA Technical Reports Server (NTRS)

    Abdul-Aziz, Ali; Downey, James; Ghosn, Louis J.; Baaklini, George Y.

    2004-01-01

    Nondestructive evaluation (NDE) is one of several technologies applied at NASA Glenn Research Center to determine atypical deformities, cracks, and other anomalies experienced by structural components. NDE consists of applying high-quality imaging techniques (such as x-ray imaging and computed tomography (CT)) to discover hidden manufactured flaws in a structure. Efforts are in progress to integrate NDE with the finite element (FE) computational method to perform detailed structural analysis of a given component. This report presents the core outlines for an in-house technical procedure that incorporates this combined NDE-FE interrelation. An example is presented to demonstrate the applicability of this analytical procedure. FE analysis of a test specimen is performed, and the resulting von Mises stresses and the stress concentrations near the anomalies are observed, which indicates the fidelity of the procedure. Additional information elaborating on the steps needed to perform such an analysis is clearly presented in the form of mini step-by-step guidelines.

  11. Foetal images: the power of visual technology in antenatal care and the implications for women's reproductive freedom.

    PubMed

    Zechmeister, I

    2001-01-01

    Continuing medico-technical progress has led to an increasing medicalisation of pregnancy and childbirth. One of the most common technologies in this context is ultrasound. Based on some identified 'pro-technology feminist theories', notably the postmodernist feminist discourse, the technology of ultrasound is analysed focusing mainly on social and political rather than clinical issues. As empirical research suggests, ultrasound is welcomed by the majority of women. The analysis, however, shows that attitudes and decisions of women are influenced by broader social aspects. Furthermore, it demonstrates how the visual technology of ultrasound, in addition to other reproductive technology in maternity care, is linked to the 'personification' of the foetus and has therefore contributed to a new image of the foetus. The exploration of these issues challenges some arguments of feminist discourse. It draws attention to possible adverse implications of the technology for women's reproductive freedom and indicates the importance of the topic for political discussions.

  12. Scientific, technological, and economic aspects of rapid tooling by electric arc spray forming

    NASA Astrophysics Data System (ADS)

    Grant, P. S.; Duncan, S. R.; Roche, A.; Johnson, C. F.

    2006-12-01

    For the last seven years, Oxford University and Ford Motor Company personnel have been researching jointly the development of the large-scale spray forming of steel tooling capable for use in mass production, particularly for the pressing of sheet metal in automotive applications. These investigations have involved: the comprehensive microstructure and property studies, modeling of shape evolution and heat flow, realtime feedback control of tool temperature to eliminate tool distortion, high-speed imaging and particle image velocimetry of droplet deposition on three-dimensional (3D) shapes, testing of full-scale tools for different applications in the production environment, and detailed studies of the cost and time savings realized for different tooling applications. This paper provides an overview of the scientific and technical progress to date, presents the latest results, and describes the current state-of-the-art. Many of the insights described have relevance and applicability across the family of thermal spray processes and applications.

  13. Technical aspects of contrast-enhanced ultrasound (CEUS) examinations: tips and tricks.

    PubMed

    Greis, C

    2014-01-01

    Ultrasound contrast agents have substantially extended the clinical value of ultrasound, allowing the assessment of blood flow and distribution in real-time down to microcapillary level. Selective imaging of contrast agent signals requires a contrast-specific imaging mode on the ultrasound scanner, allowing real-time separation of tissue and contrast agent signals. The creation of a contrast image requires a specific interaction between the insonated ultrasound wave and the contrast agent microbubbles, leading to persistent oscillation of the bubbles. Several technical and procedural parameters have a significant influence on the quality of CEUS images and should be controlled carefully to obtain good image quality and a reliable diagnosis. Achieving the proper balance between the respective parameters is a matter of technical knowledge and experience. Appropriate training and education should be mandatory for every investigator performing CEUS examinations.

  14. Investigation related to multispectral imaging systems

    NASA Technical Reports Server (NTRS)

    Nalepka, R. F.; Erickson, J. D.

    1974-01-01

    A summary of technical progress made during a five year research program directed toward the development of operational information systems based on multispectral sensing and the use of these systems in earth-resource survey applications is presented. Efforts were undertaken during this program to: (1) improve the basic understanding of the many facets of multispectral remote sensing, (2) develop methods for improving the accuracy of information generated by remote sensing systems, (3) improve the efficiency of data processing and information extraction techniques to enhance the cost-effectiveness of remote sensing systems, (4) investigate additional problems having potential remote sensing solutions, and (5) apply the existing and developing technology for specific users and document and transfer that technology to the remote sensing community.

  15. The role of fMRI in drug development

    PubMed Central

    Carmichael, Owen; Schwarz, Adam J.; Chatham, Christopher H.; Scott, David; Turner, Jessica A.; Upadhyay, Jaymin; Coimbra, Alexandre; Goodman, James A.; Baumgartner, Richard; English, Brett A.; Apolzan, John W.; Shankapal, Preetham; Hawkins, Keely R.

    2017-01-01

    Functional magnetic resonance imaging (fMRI) has been known for over a decade to have the potential to greatly enhance the process of developing novel therapeutic drugs for prevalent health conditions. However, the use of fMRI in drug development continues to be relatively limited because of a variety of technical, biological, and strategic barriers that continue to limit progress. Here, we briefly review the roles that fMRI can have in the drug development process and the requirements it must meet to be useful in this setting. We then provide an update on our current understanding of the strengths and limitations of fMRI as a tool for drug developers and recommend activities to enhance its utility. PMID:29154758

  16. Taking the ruler to the jungle: single-molecule FRET for understanding biomolecular structure and dynamics in live cells.

    PubMed

    Sustarsic, Marko; Kapanidis, Achillefs N

    2015-10-01

    Single-molecule Förster resonance energy transfer (smFRET) serves as a molecular ruler that is ideally posed to study static and dynamic heterogeneity in living cells. Observing smFRET in cells requires appropriately integrated labeling, internalization and imaging strategies, and significant progress has been made towards that goal. Pioneering studies have demonstrated smFRET detection in both prokaryotic and eukaryotic systems, using both wide-field and confocal microscopies, and have started to answer exciting biological questions. We anticipate that future technical developments will open the door to smFRET for the study of structure, conformational changes and kinetics of biomolecules in living cells. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Proceedings: Computer Science and Data Systems Technical Symposium, volume 2

    NASA Technical Reports Server (NTRS)

    Larsen, Ronald L.; Wallgren, Kenneth

    1985-01-01

    Progress reports and technical updates of programs being performed by NASA centers are covered. Presentations in viewgraph form, along with abstracts, are included for topics in three catagories: computer science, data systems, and space station applications.

  18. A study on operation efficiency evaluation based on firm's financial index and benchmark selection: take China Unicom as an example

    NASA Astrophysics Data System (ADS)

    Wu, Zu-guang; Tian, Zhan-jun; Liu, Hui; Huang, Rui; Zhu, Guo-hua

    2009-07-01

    Being the only listed telecom operators of A share market, China Unicom has always been attracted many institutional investors under the concept of 3G recent years,which itself is a great technical progress expectation.Do the institutional investors or the concept of technical progress have signficant effect on the improving of firm's operating efficiency?Though reviewing the documentary about operating efficiency we find that schoolars study this problem useing the regress analyzing based on traditional production function and data envelopment analysis(DEA) and financial index anayzing and marginal function and capital labor ratio coefficient etc. All the methods mainly based on macrodata. This paper we use the micro-data of company to evaluate the operating efficiency.Using factor analyzing based on financial index and comparing the factor score of three years from 2005 to 2007, we find that China Unicom's operating efficiency is under the averge level of benchmark corporates and has't improved under the concept of 3G from 2005 to 2007.In other words,institutional investor or the conception of technical progress expectation have faint effect on the changes of China Unicom's operating efficiency. Selecting benchmark corporates as post to evaluate the operating efficiency is a characteristic of this method ,which is basicallly sipmly and direct.This method is suit for the operation efficiency evaluation of agriculture listed companies because agriculture listed also face technical progress and marketing concept such as tax-free etc.

  19. Decontamination Systems Information and Research Program. Quarterly technical progress report, January 1--March 31, 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-05-01

    West Virginia University (WVU) and the US DOE Morgantown Energy Technology Center (METC) entered into a Cooperative Agreement on August 29, 1992 entitled ``Decontamination Systems Information and Research Programs.`` Stipulated within the Agreement is the requirement that WVU submit to METC a series of Technical Progress Reports on a quarterly basis. This report comprises the first Quarterly Technical Progress Report for Year 2 of the Agreement. This report reflects the progress and/or efforts performed on the sixteen (16) technical projects encompassed by the Year 2 Agreement for the period of January 1 through March 31, 1994. In situ bioremediation ofmore » chlorinated organic solvents; Microbial enrichment for enhancing in-situ biodegradation of hazardous organic wastes; Treatment of volatile organic compounds (VOCs) using biofilters; Drain-enhanced soil flushing (DESF) for organic contaminants removal; Chemical destruction of chlorinated organic compounds; Remediation of hazardous sites with steam reforming; Soil decontamination with a packed flotation column; Use of granular activated carbon columns for the simultaneous removal of organics, heavy metals, and radionuclides; Monolayer and multilayer self-assembled polyion films for gas-phase chemical sensors; Compact mercuric iodide detector technology development; Evaluation of IR and mass spectrometric techniques for on-site monitoring of volatile organic compounds; A systematic database of the state of hazardous waste clean-up technologies; Dust control methods for insitu nuclear and hazardous waste handling; Winfield Lock and Dam remediation; and Socio-economic assessment of alternative environmental restoration technologies.« less

  20. Technical note: DIRART--A software suite for deformable image registration and adaptive radiotherapy research.

    PubMed

    Yang, Deshan; Brame, Scott; El Naqa, Issam; Aditya, Apte; Wu, Yu; Goddu, S Murty; Mutic, Sasa; Deasy, Joseph O; Low, Daniel A

    2011-01-01

    Recent years have witnessed tremendous progress in image guide radiotherapy technology and a growing interest in the possibilities for adapting treatment planning and delivery over the course of treatment. One obstacle faced by the research community has been the lack of a comprehensive open-source software toolkit dedicated for adaptive radiotherapy (ART). To address this need, the authors have developed a software suite called the Deformable Image Registration and Adaptive Radiotherapy Toolkit (DIRART). DIRART is an open-source toolkit developed in MATLAB. It is designed in an object-oriented style with focus on user-friendliness, features, and flexibility. It contains four classes of DIR algorithms, including the newer inverse consistency algorithms to provide consistent displacement vector field in both directions. It also contains common ART functions, an integrated graphical user interface, a variety of visualization and image-processing features, dose metric analysis functions, and interface routines. These interface routines make DIRART a powerful complement to the Computational Environment for Radiotherapy Research (CERR) and popular image-processing toolkits such as ITK. DIRART provides a set of image processing/registration algorithms and postprocessing functions to facilitate the development and testing of DIR algorithms. It also offers a good amount of options for DIR results visualization, evaluation, and validation. By exchanging data with treatment planning systems via DICOM-RT files and CERR, and by bringing image registration algorithms closer to radiotherapy applications, DIRART is potentially a convenient and flexible platform that may facilitate ART and DIR research. 0 2011 Ameri-

  1. Conceptual transitions in methods of skull-photo superimposition that impact the reliability of identification: a review.

    PubMed

    Jayaprakash, Paul T

    2015-01-01

    Establishing identification during skull-photo superimposition relies on correlating the salient morphological features of an unidentified skull with those of a face-image of a suspected dead individual using image overlay processes. Technical progression in the process of overlay has included the incorporation of video cameras, image-mixing devices and software that enables real-time vision-mixing. Conceptual transitions occur in the superimposition methods that involve 'life-size' images, that achieve orientation of the skull to the posture of the face in the photograph and that assess the extent of match. A recent report on the reliability of identification using the superimposition method adopted the currently prevalent methods and suggested an increased rate of failures when skulls were compared with related and unrelated face images. The reported reduction in the reliability of the superimposition method prompted a review of the transition in the concepts that are involved in skull-photo superimposition. The prevalent popular methods for visualizing the superimposed images at less than 'life-size', overlaying skull-face images by relying on the cranial and facial landmarks in the frontal plane when orienting the skull for matching and evaluating the match on a morphological basis by relying on mix-mode alone are the major departures in the methodology that may have reduced the identification reliability. The need to reassess the reliability of the method that incorporates the concepts which have been considered appropriate by the practitioners is stressed. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  2. Non-invasive three-dimensional imaging of Escherichia coli K1 infection using diffuse light imaging tomography combined with micro-computed tomography.

    PubMed

    Witcomb, Luci A; Czupryna, Julie; Francis, Kevin P; Frankel, Gad; Taylor, Peter W

    2017-08-15

    In contrast to two-dimensional bioluminescence imaging, three dimensional diffuse light imaging tomography with integrated micro-computed tomography (DLIT-μCT) has the potential to realise spatial variations in infection patterns when imaging experimental animals dosed with derivatives of virulent bacteria carrying bioluminescent reporter genes such as the lux operon from the bacterium Photorhabdus luminescens. The method provides an opportunity to precisely localise the bacterial infection sites within the animal and enables the generation of four-dimensional movies of the infection cycle. Here, we describe the use of the PerkinElmer IVIS SpectrumCT in vivo imaging system to investigate progression of lethal systemic infection in neonatal rats following colonisation of the gastrointestinal tract with the neonatal pathogen Escherichia coli K1. We confirm previous observations that these bacteria stably colonize the colon and small intestine following feeding of the infectious dose from a micropipette; invading bacteria migrate across the gut epithelium into the blood circulation and establish foci of infection in major organs, including the brain. DLIT-μCT revealed novel multiple sites of colonisation within the alimentary canal, including the tongue, oesophagus and stomach, with penetration of the non-keratinised oesophageal epithelial surface, providing strong evidence of a further major site for bacterial dissemination. We highlight technical issues associated with imaging of infections in new born rat pups and show that the whole-body and organ bioburden correlates with disease severity. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Seizing the Future: How Ohio's Career-Technical Education Programs Fuse Academic Rigor and Real-World Experiences to Prepare Students for College and Careers

    ERIC Educational Resources Information Center

    Guarino, Heidi; Yoder, Shaun

    2015-01-01

    "Seizing the Future: How Ohio's Career and Technical Education Programs Fuse Academic Rigor and Real-World Experiences to Prepare Students for College and Work," demonstrates Ohio's progress in developing strong policies for career and technical education (CTE) programs to promote rigor, including college- and career-ready graduation…

  4. Case Study on Technical and Vocational Education in Japan. Case Studies on Technical and Vocational Education in Asia and the Pacific.

    ERIC Educational Resources Information Center

    Iwamoto, Muneharu

    In the course of Japan's economic progress, remarkable changes have occurred in the structure of industry and employment. Workers are in extremely short supply in such occupations as mining, manufacturing and construction, services, transportation and communication, sales, and professional and technical. On the basis of recommendations of the…

  5. 25 CFR 30.104 - What is the Secretary's definition of AYP?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... PROGRESS Defining Adequate Yearly Progress § 30.104 What is the Secretary's definition of AYP? The... accepted by the Department of Education. The Secretary is committed to providing technical assistance to a...

  6. 25 CFR 30.104 - What is the Secretary's definition of AYP?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... PROGRESS Defining Adequate Yearly Progress § 30.104 What is the Secretary's definition of AYP? The... accepted by the Department of Education. The Secretary is committed to providing technical assistance to a...

  7. SU-E-CAMPUS-J-04: Image Guided Radiation Therapy (IGRT): Review of Technical Standards and Credentialing in Radiotherapy Clinical Trials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giaddui, T; Chen, W; Yu, J

    2014-06-15

    Purpose: To review IGRT credentialing experience and unexpected technical issues encountered in connection with advanced radiotherapy technologies as implemented in RTOG clinical trials. To update IGRT credentialing procedures with the aim of improving the quality of the process, and to increase the proportion of IGRT credentialing compliance. To develop a living disease site-specific IGRT encyclopedia. Methods: Numerous technical issues were encountered during the IGRT credentialing process. The criteria used for credentialing review were based on: image quality; anatomy included in fused data sets and shift results. Credentialing requirements have been updated according to the AAPM task group reports for IGRTmore » to ensure that all required technical items are included in the quality review process. Implementation instructions have been updated and expanded for recent protocols. Results: Technical issues observed during the credentialing review process include, but are not limited to: poor quality images; inadequate image acquisition region; poor data quality; shifts larger than acceptable; no soft tissue surrogate. The updated IGRT credentialing process will address these issues and will also include the technical items required from AAPM: TG 104; TG 142 and TG 179 reports. An instruction manual has been developed describing a remote credentialing method for reviewers. Submission requirements are updated, including images/documents as well as facility questionnaire. The review report now includes summary of the review process and the parameters that reviewers check. We have reached consensus on the minimum IGRT technical requirement for a number of disease sites. RTOG 1311(NRG-BR002A Phase 1 Study of Stereotactic Body Radiotherapy (SBRT) for the Treatment of Multiple Metastases) is an example, here; the protocol specified the minimum requirement for each anatomical sites (with/without fiducials). Conclusion: Technical issues are identified and reported. IGRT guidelines are updated, with the corresponding credentialing requirements. An IGRT encyclopedia describing site-specific implementation issues is currently in development.« less

  8. A Novel Passive Millimeter Imager for Broad-Area Search - Final Report on Project PL09-NPMI-PD07 (PNNL-55180)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tedeschi, Jonathan R.; Bernacki, Bruce E.; Kelly, James F.

    2011-12-31

    This report describes research and development efforts toward a novel passive millimeter-wave (mm-wave) electromagnetic imaging device for broad-area search. It addresses the technical challenge of detecting anomalies that occupy a small fraction of a pixel. The purpose of the imager is to pinpoint suspicious locations for cuing subsequent higher-resolution imaging. The technical basis for the approach is to exploit thermal and polarization anomalies that distinguish man-made features from natural features.

  9. Recognizing 3 D Objects from 2D Images Using Structural Knowledge Base of Genetic Views

    DTIC Science & Technology

    1988-08-31

    technical report. [BIE85] I. Biederman , "Human image understanding: Recent research and a theory", Computer Vision, Graphics, and Image Processing, vol...model bases", Technical Report 87-85, COINS Dept, University of Massachusetts, Amherst, MA 01003, August 1987 . [BUR87b) Burns, J. B. and L. J. Kitchen...34Recognition in 2D images of 3D objects from large model bases using prediction hierarchies", Proc. IJCAI-10, 1987 . [BUR891 J. B. Burns, forthcoming

  10. Gloss uniformity measurement update for ISO/IEC 19751

    NASA Astrophysics Data System (ADS)

    Ng, Yee S.; Cui, Chengwu; Kuo, Chunghui; Maggard, Eric; Mashtare, Dale; Morris, Peter

    2005-01-01

    To address the standardization issues of perceptually based image quality for printing systems, ISO/IEC JTC1/SC28, the standardization committee for office equipment chartered the W1.1 project with the responsibility of drafting a proposal for an international standard for the evaluation of printed image quality1. An ISO draft Standard2, ISO/WD 19751-1, Office Equipment - Appearance-based image quality standards for printers - Part 1: Overview, Procedure and Common Methods, 2004 describes the overview of this multi-part appearance-based image quality standard. One of the ISO 19751 multi-part Standard"s tasks is to address the appearance-based gloss and gloss uniformity issues (in ISO 19751-2). This paper summarizes the current status and technical progress since the last two updates3, 4. In particular, we will be discussion our attempt to include 75 degree gloss (G75) objective measurement5 in differential gloss and within-page gloss uniformity. The result for a round-robin experiment involving objective measurement of differential gloss using G60 and G75 gloss measurement geometry is described. The results for two perceptual-based round-robin experiments relating to haze effect on the perception of gloss, and gloss artifacts (gloss streaks/bands, gloss graininess/mottle) are discussed.

  11. Gloss uniformity measurement update for ISO/IEC 19751

    NASA Astrophysics Data System (ADS)

    Ng, Yee S.; Cui, Chengwu; Kuo, Chunghui; Maggard, Eric; Mashtare, Dale; Morris, Peter

    2004-10-01

    To address the standardization issues of perceptually based image quality for printing systems, ISO/IEC JTC1/SC28, the standardization committee for office equipment chartered the W1.1 project with the responsibility of drafting a proposal for an international standard for the evaluation of printed image quality1. An ISO draft Standard2, ISO/WD 19751-1, Office Equipment - Appearance-based image quality standards for printers - Part 1: Overview, Procedure and Common Methods, 2004 describes the overview of this multi-part appearance-based image quality standard. One of the ISO 19751 multi-part Standard"s tasks is to address the appearance-based gloss and gloss uniformity issues (in ISO 19751-2). This paper summarizes the current status and technical progress since the last two updates3, 4. In particular, we will be discussion our attempt to include 75 degree gloss (G75) objective measurement5 in differential gloss and within-page gloss uniformity. The result for a round-robin experiment involving objective measurement of differential gloss using G60 and G75 gloss measurement geometry is described. The results for two perceptual-based round-robin experiments relating to haze effect on the perception of gloss, and gloss artifacts (gloss streaks/bands, gloss graininess/mottle) are discussed.

  12. Fabrication of FORTIS

    NASA Astrophysics Data System (ADS)

    McCandliss, Stephan R.; Fleming, Brian; Kaiser, Mary Elizabeth; Kruk, Jeffrey; Feldman, Paul D.; Kutyrev, Alexander S.; Li, Mary J.; Goodwin, Phillip A.; Rapchun, David; Lyness, Eric; Brown, Ari D.; Moseley, Harvey; Siegmund, Oswald; Vallerga, John

    2010-07-01

    The Johns Hopkins University sounding rocket group is building the Far-ultraviolet Off Rowland-circle Telescope for Imaging and Spectroscopy (FORTIS), which is a Gregorian telescope with rulings on the secondary mirror. FORTIS will be launched on a sounding rocket from White Sand Missile Range to study the relationship between Lyman alpha escape and the local gas-to-dust ratio in star forming galaxies with non-zero redshifts. It is designed to acquire images of a 30' x 30' field and provide fully redundant "on-the-fly" spectral acquisition of 43 separate targets in the field with a bandpass of 900 - 1800 Angstroms. FORTIS is an enabling scientific and technical activity for future cutting edge far- and near-uv survey missions seeking to: search for Lyman continuum radiation leaking from star forming galaxies, determine the epoch of He II reionization and characterize baryon acoustic oscillations using the Lyman forest. In addition to the high efficiency "two bounce" dual-order spectro-telescope design, FORTIS incorporates a number of innovative technologies including: an image dissecting microshutter array developed by GSFC; a large area (~ 45 mm x 170 mm) microchannel plate detector with central imaging and "outrigger" spectral channels provided by Sensor Sciences; and an autonomous targeting microprocessor incorporating commercially available field programable gate arrays. We discuss progress to date in developing our pathfinder instrument.

  13. ANNUAL REPORT, JULY 1, 1958

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1959-02-01

    This annual report of Brookhaven National Laboratory describes its program and activities for the fiscal year 1958. The progress and trends of the research program are presented along with a description of the operational, service, and administrative activities of the Laboratory. The scientific and technical details of the many research and development activities are covered more fully in scientific and technical periodicals and in the quarterly scientific progress reports and other scientiflc reports of the Laboratory. A list of all publications for July 1, 1957 to June 30, 1958, is given. Status and progress are given in fields of physics,more » accelerator development, instrumentation, applied mathematics, chemistry, nuclear engineering, biology, and medical research. (For preceding period see BNL-462.) (W.D.M.)« less

  14. Cardiac CT for myocardial ischaemia detection and characterization--comparative analysis.

    PubMed

    Bucher, A M; De Cecco, C N; Schoepf, U J; Wang, R; Meinel, F G; Binukrishnan, S R; Spearman, J V; Vogl, T J; Ruzsics, B

    2014-11-01

    The assessment of patients presenting with symptoms of myocardial ischaemia remains one of the most common and challenging clinical scenarios faced by physicians. Current imaging modalities are capable of three-dimensional, functional and anatomical views of the heart and as such offer a unique contribution to understanding and managing the pathology involved. Evidence has accumulated that visual anatomical coronary evaluation does not adequately predict haemodynamic relevance and should be complemented by physiological evaluation, highlighting the importance of functional assessment. Technical advances in CT technology over the past decade have progressively moved cardiac CT imaging into the clinical workflow. In addition to anatomical evaluation, cardiac CT is capable of providing myocardial perfusion parameters. A variety of CT techniques can be used to assess the myocardial perfusion. The single energy first-pass CT and dual energy first-pass CT allow static assessment of myocardial blood pool. Dynamic cardiac CT imaging allows quantification of myocardial perfusion through time-resolved attenuation data. CT-based myocardial perfusion imaging (MPI) is showing promising diagnostic accuracy compared with the current reference modalities. The aim of this review is to present currently available myocardial perfusion techniques with a focus on CT imaging in light of recent clinical investigations. This article provides a comprehensive overview of currently available CT approaches of static and dynamic MPI and presents the results of corresponding clinical trials.

  15. Automated fluorescent miscroscopic image analysis of PTBP1 expression in glioma

    PubMed Central

    Becker, Aline; Elder, Brad; Puduvalli, Vinay; Winter, Jessica; Gurcan, Metin

    2017-01-01

    Multiplexed immunofluorescent testing has not entered into diagnostic neuropathology due to the presence of several technical barriers, amongst which includes autofluorescence. This study presents the implementation of a methodology capable of overcoming the visual challenges of fluorescent microscopy for diagnostic neuropathology by using automated digital image analysis, with long term goal of providing unbiased quantitative analyses of multiplexed biomarkers for solid tissue neuropathology. In this study, we validated PTBP1, a putative biomarker for glioma, and tested the extent to which immunofluorescent microscopy combined with automated and unbiased image analysis would permit the utility of PTBP1 as a biomarker to distinguish diagnostically challenging surgical biopsies. As a paradigm, we utilized second resections from patients diagnosed either with reactive brain changes (pseudoprogression) and recurrent glioblastoma (true progression). Our image analysis workflow was capable of removing background autofluorescence and permitted quantification of DAPI-PTBP1 positive cells. PTBP1-positive nuclei, and the mean intensity value of PTBP1 signal in cells. Traditional pathological interpretation was unable to distinguish between groups due to unacceptably high discordance rates amongst expert neuropathologists. Our data demonstrated that recurrent glioblastoma showed more DAPI-PTBP1 positive cells and a higher mean intensity value of PTBP1 signal compared to resections from second surgeries that showed only reactive gliosis. Our work demonstrates the potential of utilizing automated image analysis to overcome the challenges of implementing fluorescent microscopy in diagnostic neuropathology. PMID:28282372

  16. Towards a space-borne quantum gravity gradiometer: progress in laboratory demonstration

    NASA Technical Reports Server (NTRS)

    Yu, Nan; Kohel, James M.; Kellogg, James R.; Maleki, Lute

    2005-01-01

    This paper describes the working principles and technical benefits of atom-wave interferometer-based inertial sensors, and gives a progress report on the development of a quantum gravity gradiometer for space applications at JPL.

  17. Technical Progress of the New Worlds Observer Mission

    NASA Astrophysics Data System (ADS)

    Lo, Amy; Noecker, C.; Cash, W.; NWO Study Team

    2009-01-01

    We report on the technical progress of the New Worlds Observer (NWO) mission concept. NWO is a two spacecraft mission that is capable of detecting and characterizing extra-solar, terrestrial planets and planetary systems. NWO consists of an external starshade and an UV-optical space telescope, flying in tandem. The starshade is a petal-shaped, opaque screen that creates an extremely dark shadow large enough to shade the telescope aperture from the target star. The NWO team has been addressing the top technology challenges of the concept, and report here our progress. We will present the current mission configuration best suited to address Terrestrial Planet Finding requirements, and highlight the technological breakthroughs that we have achieved this year. In particular, we will report on progress made in precision deployables for the large starshade, and the trajectory & alignment control system for NWO. We will also briefly highlight advances in understanding the starshade optical performance.

  18. Interventional Oncology in Hepatocellular Carcinoma: Progress Through Innovation.

    PubMed

    Mu, Lin; Chapiro, Julius; Stringam, Jeremiah; Geschwind, Jean-François

    The clinical management of hepatocellular carcinoma has evolved greatly in the last decade mostly through recent technical innovations. In particular, the application of cutting-edge image guidance has led to minimally invasive solutions for complex clinical problems and rapid advances in the field of interventional oncology. Many image-guided therapies, such as transarterial chemoembolization and radiofrequency ablation, have meanwhile been fully integrated into interdisciplinary clinical practice, whereas others are currently being investigated. This review summarizes and evaluates the most relevant completed and ongoing clinical trials, provides a synopsis of recent innovations in the field of intraprocedural imaging and tumor response assessment, and offers an outlook on new technologies, such as radiopaque embolic materials. In addition, combination therapies consisting of locoregional therapies and systemic molecular targeted agents (e.g., sorafenib) remain of major interest to the field and are also discussed. Finally, we address the many substantial advances in immune response pathways that have been related to the systemic effects of locoregional therapies. Knowledge of these new developments is crucial as they continue to shape the future of cancer treatment, further establishing interventional oncology along with surgical, medical, and radiation oncology as the fourth pillar of cancer care.

  19. Methods and algorithms for optical coherence tomography-based angiography: a review and comparison

    NASA Astrophysics Data System (ADS)

    Zhang, Anqi; Zhang, Qinqin; Chen, Chieh-Li; Wang, Ruikang K.

    2015-10-01

    Optical coherence tomography (OCT)-based angiography is increasingly becoming a clinically useful and important imaging technique due to its ability to provide volumetric microvascular networks innervating tissue beds in vivo without a need for exogenous contrast agent. Numerous OCT angiography algorithms have recently been proposed for the purpose of contrasting microvascular networks. A general literature review is provided on the recent progress of OCT angiography methods and algorithms. The basic physics and mathematics behind each method together with its contrast mechanism are described. Potential directions for future technical development of OCT based angiography is then briefly discussed. Finally, by the use of clinical data captured from normal and pathological subjects, the imaging performance of vascular networks delivered by the most recently reported algorithms is evaluated and compared, including optical microangiography, speckle variance, phase variance, split-spectrum amplitude decorrelation angiography, and correlation mapping. It is found that the method that utilizes complex OCT signal to contrast retinal blood flow delivers the best performance among all the algorithms in terms of image contrast and vessel connectivity. The purpose of this review is to help readers understand and select appropriate OCT angiography algorithm for use in specific applications.

  20. Using multidimensional topological data analysis to identify traits of hip osteoarthritis.

    PubMed

    Rossi-deVries, Jasmine; Pedoia, Valentina; Samaan, Michael A; Ferguson, Adam R; Souza, Richard B; Majumdar, Sharmila

    2018-05-07

    Osteoarthritis (OA) is a multifaceted disease with many variables affecting diagnosis and progression. Topological data analysis (TDA) is a state-of-the-art big data analytics tool that can combine all variables into multidimensional space. TDA is used to simultaneously analyze imaging and gait analysis techniques. To identify biochemical and biomechanical biomarkers able to classify different disease progression phenotypes in subjects with and without radiographic signs of hip OA. Longitudinal study for comparison of progressive and nonprogressive subjects. In all, 102 subjects with and without radiographic signs of hip osteoarthritis. 3T, SPGR 3D MAPSS T 1ρ /T 2 , intermediate-weighted fat-suppressed fast spin-echo (FSE). Multidimensional data analysis including cartilage composition, bone shape, Kellgren-Lawrence (KL) classification of osteoarthritis, scoring hip osteoarthritis with MRI (SHOMRI), hip disability and osteoarthritis outcome score (HOOS). Analysis done using TDA, Kolmogorov-Smirnov (KS) testing, and Benjamini-Hochberg to rank P-value results to correct for multiple comparisons. Subjects in the later stages of the disease had an increased SHOMRI score (P < 0.0001), increased KL (P = 0.0012), and older age (P < 0.0001). Subjects in the healthier group showed intact cartilage and less pain. Subjects found between these two groups had a range of symptoms. Analysis of this subgroup identified knee biomechanics (P < 0.0001) as an initial marker of the disease that is noticeable before the morphological progression and degeneration. Further analysis of an OA subgroup with femoroacetabular impingement (FAI) showed anterior labral tears to be the most significant marker (P = 0.0017) between those FAI subjects with and without OA symptoms. The data-driven analysis obtained with TDA proposes new phenotypes of these subjects that partially overlap with the radiographic-based classical disease status classification and also shows the potential for further examination of an early onset biomechanical intervention. 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  1. Effects of Company Visits on Dutch Primary School Children's Attitudes toward Technical Professions

    ERIC Educational Resources Information Center

    Post, Tim; Walma van der Molen, Juliette H.

    2014-01-01

    Technology-oriented company visits could potentially provide children with a stimulating "real-world" setting to develop more broad and positive images of and attitudes toward technology and technical professions. The present study was the first to explore whether children's images of and attitudes toward technology, technical…

  2. Current progress and technical challenges of flexible liquid crystal displays

    NASA Astrophysics Data System (ADS)

    Fujikake, Hideo; Sato, Hiroto

    2009-02-01

    We focused on several technical approaches to flexible liquid crystal (LC) display in this report. We have been developing flexible displays using plastic film substrates based on polymer-dispersed LC technology with molecular alignment control. In our representative devices, molecular-aligned polymer walls keep plastic-substrate gap constant without LC alignment disorder, and aligned polymer networks create monostable switching of fast-response ferroelectric LC (FLC) for grayscale capability. In the fabrication process, a high-viscosity FLC/monomer solution was printed, sandwiched and pressed between plastic substrates. Then the polymer walls and networks were sequentially formed based on photo-polymerization-induced phase separation in the nematic phase by two exposure processes of patterned and uniform ultraviolet light. The two flexible backlight films of direct illumination and light-guide methods using small three-primary-color light-emitting diodes were fabricated to obtain high-visibility display images. The fabricated flexible FLC panels were driven by external transistor arrays, internal organic thin film transistor (TFT) arrays, and poly-Si TFT arrays. We achieved full-color moving-image displays using the flexible FLC panel and the flexible backlight film based on field-sequential-color driving technique. Otherwise, for backlight-free flexible LC displays, flexible reflective devices of twisted guest-host nematic LC and cholesteric LC were discussed with molecular-aligned polymer walls. Singlesubstrate device structure and fabrication method using self-standing polymer-stabilized nematic LC film and polymer ceiling layer were also proposed for obtaining LC devices with excellent flexibility.

  3. A Review of Adaptive Optics Optical Coherence Tomography: Technical Advances, Scientific Applications, and the Future.

    PubMed

    Jonnal, Ravi S; Kocaoglu, Omer P; Zawadzki, Robert J; Liu, Zhuolin; Miller, Donald T; Werner, John S

    2016-07-01

    Optical coherence tomography (OCT) has enabled "virtual biopsy" of the living human retina, revolutionizing both basic retina research and clinical practice over the past 25 years. For most of those years, in parallel, adaptive optics (AO) has been used to improve the transverse resolution of ophthalmoscopes to foster in vivo study of the retina at the microscopic level. Here, we review work done over the last 15 years to combine the microscopic transverse resolution of AO with the microscopic axial resolution of OCT, building AO-OCT systems with the highest three-dimensional resolution of any existing retinal imaging modality. We surveyed the literature to identify the most influential antecedent work, important milestones in the development of AO-OCT technology, its applications that have yielded new knowledge, research areas into which it may productively expand, and nascent applications that have the potential to grow. Initial efforts focused on demonstrating three-dimensional resolution. Since then, many improvements have been made in resolution and speed, as well as other enhancements of acquisition and postprocessing techniques. Progress on these fronts has produced numerous discoveries about the anatomy, function, and optical properties of the retina. Adaptive optics OCT continues to evolve technically and to contribute to our basic and clinical knowledge of the retina. Due to its capacity to reveal cellular and microscopic detail invisible to clinical OCT systems, it is an ideal companion to those instruments and has the demonstrable potential to produce images that can guide the interpretation of clinical findings.

  4. Percutaneous Dual-Switching Monopolar Radiofrequency Ablation Using a Separable Clustered Electrode: A Preliminary Study

    PubMed Central

    Choi, Tae Won; Lee, Dong Ho; Lee, Jeong-Hoon; Yu, Su Jong; Kim, Yoon Jun; Yoon, Jung-Hwan; Han, Joon Koo

    2017-01-01

    Objective To prospectively evaluate the safety and therapeutic effectiveness of dual-switching monopolar (DSM) radiofrequency ablation (RFA) for the treatment of hepatocellular carcinoma (HCC), and to retrospectively compare the results with those of single-switching monopolar (SSM) RFA in a historical control group. Materials and Methods This study was approved by the Institutional Review Board, with informed consent obtained from all patients. Fifty-two HCC patients who underwent DSM-RFA using a separable clustered electrode and dual-generators were prospectively enrolled. Technical parameters, complications, technical success, technical effectiveness, and local tumor progression (LTP) rates were evaluated by means of post-procedural and follow-up imaging. Thereafter, the outcome of DSM-RFA was compared with those of 249 retrospectively included HCC patients treated with SSM-RFA. Results There were two major complications (3.8%, 2/52) including pleural and pericardial effusion in the DSM-RFA group. The DSM-RFA yielded a 100% technical success rate, a 98.1% technical effectiveness rate, and a 4.3% 2-year LTP rate. In a retrospective comparison between the two groups, DSM-RFA created significantly larger ablation volume (4.20 ± 2.07 cm3/min vs. 3.03 ± 1.99 cm3/min, p < 0.01), and delivered higher energy (1.43 ± 0.37 kcal/min vs. 1.25 ± 0.50 kcal/min, p < 0.01) per given time, than SSM-RFA. There was no significant difference in major procedure-related complications (3.8% vs. 4.4%) and technical effectiveness rate (98.1% vs. 96.4%) between the two groups (p = 1.00). In addition, the 2-year LTP rate of DSM-RFA and SSM-RFA were 4.3% and 10.1%, respectively (p = 0.15). Conclusion DSM-RFA using a separable clustered electrode is safe and provides high local tumor control and good preliminary clinical outcome for small HCCs, which are at least comparable to those of SSM-RFA. PMID:28860897

  5. Technical aspects of dental CBCT: state of the art

    PubMed Central

    Araki, K; Siewerdsen, J H; Thongvigitmanee, S S

    2015-01-01

    As CBCT is widely used in dental and maxillofacial imaging, it is important for users as well as referring practitioners to understand the basic concepts of this imaging modality. This review covers the technical aspects of each part of the CBCT imaging chain. First, an overview is given of the hardware of a CBCT device. The principles of cone beam image acquisition and image reconstruction are described. Optimization of imaging protocols in CBCT is briefly discussed. Finally, basic and advanced visualization methods are illustrated. Certain topics in these review are applicable to all types of radiographic imaging (e.g. the principle and properties of an X-ray tube), others are specific for dental CBCT imaging (e.g. advanced visualization techniques). PMID:25263643

  6. Amarillo National Resource Center for Plutonium. Quarterly technical progress report, May 1, 1997--July 31, 1997

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Progress summaries are provided from the Amarillo National Center for Plutonium. Programs include the plutonium information resource center, environment, public health, and safety, education and training, nuclear and other material studies.

  7. Urology technical and non-technical skills development: the emerging role of simulation.

    PubMed

    Rashid, Prem; Gianduzzo, Troy R J

    2016-04-01

    To review the emerging role of technical and non-technical simulation in urological education and training. A review was conducted to examine the current role of simulation in urology training. A PUBMED search of the terms 'urology training', 'urology simulation' and 'urology education' revealed 11,504 titles. Three hundred and fifty-seven abstracts were identified as English language, peer reviewed papers pertaining to the role of simulation in urology and related topics. Key papers were used to explore themes. Some cross-referenced papers were also included. There is an ongoing need to ensure that training time is efficiently utilised while ensuring that optimal technical and non-technical skills are achieved. Changing working conditions and the need to minimise patient harm by inadvertent errors must be taken into account. Simulation models for specific technical aspects have been the mainstay of graduated step-wise low and high fidelity training. Whole scenario environments as well as non-technical aspects can be slowly incorporated into the curriculum. Doing so should also help define what have been challenging competencies to teach and evaluate. Dedicated time, resources and trainer up-skilling are important. Concurrent studies are needed to help evaluate the effectiveness of introducing step-wise simulation for technical and non-technical competencies. Simulation based learning remains the best avenue of progressing surgical education. Technical and non-technical simulation could be used in the selection process. There are good economic, logistic and safety reasons to pursue the process of ongoing development of simulation co-curricula. While the role of simulation is assured, its progress will depend on a structured program that takes advantage of what can be delivered via this medium. Overall, simulation can be developed further for urological training programs to encompass technical and non-technical skill development at all stages, including recertification. © 2015 The Authors BJU International © 2015 BJU International Published by John Wiley & Sons Ltd.

  8. A Portfolio Analysis Tool for Measuring NASAs Aeronautics Research Progress toward Planned Strategic Outcomes

    NASA Technical Reports Server (NTRS)

    Tahmasebi, Farhad; Pearce, Robert

    2016-01-01

    Description of a tool for portfolio analysis of NASA's Aeronautics research progress toward planned community strategic Outcomes is presented. The strategic planning process for determining the community Outcomes is also briefly described. Stakeholder buy-in, partnership performance, progress of supporting Technical Challenges, and enablement forecast are used as the criteria for evaluating progress toward Outcomes. A few illustrative examples are also presented.

  9. An approach to knowledge structuring for advanced phases of the Technical and Management Information System (TMIS)

    NASA Technical Reports Server (NTRS)

    Goranson, H. T.

    1986-01-01

    The Technical and Management Information System (TMIS) must employ on enlightened approach to its object structure, but basic issues in conceptual structuring remain to be resolved. Sirius outlines the necessary agenda and reports on progress toward solutions.

  10. 48 CFR 752.7035 - Public notices.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... notices. The following clause is for use when the cognizant technical office determines that the contract... to time, to announce progress and accomplishments. Press releases or other public notices should... cognizant technical officer and to USAID's Legislative and Public Affairs (LPA) as far in advance of release...

  11. 14 CFR 1260.71 - Supplements and renewals.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., continued research relevance, and progress made by the recipient. (2) To insure uninterrupted programs, the technical office should forward to the grant office a completed award package, including a funded procurement request, technical evaluation of the proposed budget, and other support documentation, at least 29...

  12. [A technical modification of the use of Dwyer's equipment].

    PubMed

    Carlioz, H; Damsin, J P

    1991-01-01

    Dwyer's technique for correction and anterior fusion of the spine was improved by using lockers at the level of each screw. So, like with the Zielke's technic this procedure allowed a global progressive and controllable correction and a real derotation of the spine.

  13. A systematic assessment of the state of hazardous waste clean-up technologies. Quarterly technical progress report, April 1--June 30, 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berg, M.T.; Reed, B.E.; Gabr, M.

    1993-07-01

    West Virginia University (WVU) and the US DOE Morgantown Energy Technology Center (METC) entered into a Cooperative Agreement on August 29, 1992 entitled ``Decontamination Systems Information and Research Programs.`` Stipulated within the Agreement is the requirement that WVU submit to METC a series of Technical Progress Report for Year 1 of the Agreement. This report reflects the progress and/or efforts performed on the following nine technical projects encompassed by the Year 1 Agreement for the period of April 1 through June 30, 1993: Systematic assessment of the state of hazardous waste clean-up technologies; site remediation technologies -- drain-enhanced soil flushingmore » (DESF) for organic contaminants removal; site remediation technologies -- in situ bioremediation of organic contaminants; excavation systems for hazardous waste sites; chemical destruction of polychlorinated biphenyls; development of organic sensors -- monolayer and multilayer self-assembled films for chemical sensors; Winfield lock and dam remediation; Assessments of Technologies for hazardous waste site remediation -- non-treatment technologies and pilot scale test facility implementation; and remediation of hazardous sites with stream reforming.« less

  14. The Use of Virtual Reality Simulation to Improve Technical Skill in the Undergraduate Medical Imaging Student

    ERIC Educational Resources Information Center

    Gunn, Therese; Jones, Lee; Bridge, Pete; Rowntree, Pam; Nissen, Lisa

    2018-01-01

    In recent years, simulation has increasingly underpinned the acquisition of pre-clinical skills by undergraduate medical imaging (diagnostic radiography) students. This project aimed to evaluate the impact of an innovative virtual reality (VR) learning environment on the development of technical proficiency by students. The study assessed the…

  15. Technical Communication Competence and Projected Teacher Success.

    ERIC Educational Resources Information Center

    Powers, William G.; Lowry, David N.

    Technical Communication Competence (TCC)is the competence involved in communicating mental images to others in such a manner as to result in their constructing comparable mental images, a process similar to the primary task demanded of teachers at all levels. In a study designed to discover the extent to which a positive relationship existed…

  16. A Digital Approach to Learning Petrology

    NASA Astrophysics Data System (ADS)

    Reid, M. R.

    2011-12-01

    In the undergraduate igneous and metamorphic petrology course at Northern Arizona University, we are employing petrographic microscopes equipped with relatively inexpensive ( $200) digital cameras that are linked to pen-tablet computers. The camera-tablet systems can assist student learning in a variety of ways. Images provided by the tablet computers can be used for helping students filter the visually complex specimens they examine. Instructors and students can simultaneously view the same petrographic features captured by the cameras and exchange information about them by pointing to salient features using the tablet pen. These images can become part of a virtual mineral/rock/texture portfolio tailored to individual student's needs. Captured digital illustrations can be annotated with digital ink or computer graphics tools; this activity emulates essential features of more traditional line drawings (visualizing an appropriate feature and selecting a representative image of it, internalizing the feature through studying and annotating it) while minimizing the frustration that many students feel about drawing. In these ways, we aim to help a student progress more efficiently from novice to expert. A number of our petrology laboratory exercises involve use of the camera-tablet systems for collaborative learning. Observational responsibilities are distributed among individual members of teams in order to increase interdependence and accountability, and to encourage efficiency. Annotated digital images are used to share students' findings and arrive at an understanding of an entire rock suite. This interdependence increases the individual's sense of responsibility for their work, and reporting out encourages students to practice use of technical vocabulary and to defend their observations. Pre- and post-course student interest in the camera-tablet systems has been assessed. In a post-course survey, the majority of students reported that, if available, they would use camera-tablet systems to capture microscope images (77%) and to make notes on images (71%). An informal focus group recommended introducing the cameras as soon as possible and having them available for making personal mineralogy/petrology portfolios. Because the stakes are perceived as high, use of the camera-tablet systems for peer-peer learning has been progressively modified to bolster student confidence in their collaborative efforts.

  17. Progress, innovation and regulatory science in drug development: the politics of international standard-setting.

    PubMed

    Abraham, John; Reed, Tim

    2002-06-01

    This paper examines international standard-setting in the toxicology of pharmaceuticals during the 1990s, which has involved both the pharmaceutical industry and regulatory agencies in an organization known as the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH). The analysis shows that the relationships between innovation, regulatory science and 'progress' may be more complex and controversial than is often assumed. An assessment of the ICH's claims about the implications of 'technical' harmonization of drug-testing standards for the maintenance of drug safety, via toxicological testing, and the delivery of therapeutic progress, via innovation, is presented. By demonstrating that there is not a technoscientific validity for these claims, it is argued that, within the ICH, a discourse of technological innovation and scientific progress has been used by regulatory agencies and prominent parts of the transnational pharmaceutical industry to legitimize the lowering and loosening of toxicological standards for drug testing. The mobilization and acceptance of this discourse are shown to be pivotal to the ICH's transformation of reductions in safety standards, which are apparently against the interests of patients and public health, into supposed therapeutic benefits derived from promises of greater access to more innovative drug products. The evidence suggests that it is highly implausible that these reductions in the standards of regulatory toxicology are consistent with therapeutic progress for patients, and highlights a worrying aspect embedded in the 'technical trajectories' of regulatory science.

  18. 7 CFR 1944.541 - Reporting requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) PROGRAM REGULATIONS (CONTINUED) HOUSING Technical and Supervisory Assistance Grants § 1944.541 Reporting... District Director to determine satisfactory progress. The District Director will work with the grantee to... five working days of receipt. (1) If the reports indicate satisfactory progress, the State Director...

  19. The magnetohydrodynamics coal-fired flow facility

    NASA Astrophysics Data System (ADS)

    1995-01-01

    In this quarterly technical progress report, UTSI reports on the status of a multitask contract to develop the technology for the steam bottoming portion of a MHD Steam Combined Cycle Power Plant. The report describes the facility maintenance and environmental work completed, status of completing technical reports and certain key administrative actions occurring during the quarter. With program resources at a minimum to closeout the MHD program, no further testing occurred during the quarter, but the DOE CFFF facility was maintained in a standby status with winterization, preventive maintenance and repairs accomplished as needed. Plans and preparations progressed for environmental actions needed at the site to investigate and characterize the groundwater and for removal/disposal of asbestos in the cooling tower. Work continued to progress on archiving the results of the MHD program.

  20. Performance analysis of algorithms for retrieval of magnetic resonance images for interactive teleradiology

    NASA Astrophysics Data System (ADS)

    Atkins, M. Stella; Hwang, Robert; Tang, Simon

    2001-05-01

    We have implemented a prototype system consisting of a Java- based image viewer and a web server extension component for transmitting Magnetic Resonance Images (MRI) to an image viewer, to test the performance of different image retrieval techniques. We used full-resolution images, and images compressed/decompressed using the Set Partitioning in Hierarchical Trees (SPIHT) image compression algorithm. We examined the SPIHT decompression algorithm using both non- progressive and progressive transmission, focusing on the running times of the algorithm, client memory usage and garbage collection. We also compared the Java implementation with a native C++ implementation of the non- progressive SPIHT decompression variant. Our performance measurements showed that for uncompressed image retrieval using a 10Mbps Ethernet, a film of 16 MR images can be retrieved and displayed almost within interactive times. The native C++ code implementation of the client-side decoder is twice as fast as the Java decoder. If the network bandwidth is low, the high communication time for retrieving uncompressed images may be reduced by use of SPIHT-compressed images, although the image quality is then degraded. To provide diagnostic quality images, we also investigated the retrieval of up to 3 images on a MR film at full-resolution, using progressive SPIHT decompression. The Java-based implementation of progressive decompression performed badly, mainly due to the memory requirements for maintaining the image states, and the high cost of execution of the Java garbage collector. Hence, in systems where the bandwidth is high, such as found in a hospital intranet, SPIHT image compression does not provide advantages for image retrieval performance.

  1. Stent-assisted coiling of wide-neck bifurcation aneurysms with a branch incorporated in the aneurysm base: long-term follow-up in 49 patients with 53 aneurysms.

    PubMed

    Lubicz, Boris; Morais, Ricardo; Bruyère, Pierre-Julien; Ligot, Noémie; Mine, Benjamin

    2017-06-01

    Wide-neck bifurcation intracranial aneurysms (WNBA) with a branch incorporated in the aneurysm base remain difficult to treat by embolization. We aim to report our long-term follow-up of stent-assisted coiling (SAC) in this subgroup of patients. This study was approved by our local ethical committee. A retrospective review of our prospectively maintained database identified all patients treated in our institution by SAC for a WNBA with a branch incorporated in the aneurysm base. Technical issues, immediate, long-term outcomes were evaluated. Between 2007 and 2015, 49 patients with 53 intracranial aneurysms (IAs) (52 unruptured, 1 ruptured) were identified and successfully treated. No morbidity/mortality occurred. The incorporated branch was preserved in all patients but one who was treated during a vasospasm phase. At the first 6-month imaging control, the branch was patent. Immediate occlusion was near-complete in 11/53 aneurysms (20.8%), neck remnant in 20/53 aneurysms (37.7%), and incomplete in 22/53 aneurysms (41.5%). Available imaging follow-up of 47 IAs, ranging from 3 to 84 months (mean 26 months ± 19.6 months), showed 27 progressive thrombosis (57.4%), 17 stable occlusions (36.2%), 1 minor recanalization (2.1%), and 2 significant recanalizations that were retreated (4.3%). The latest imaging control showed 30 near-complete occlusions (63.8%), 13 neck remnants (27.7%), and 4 incomplete occlusions (8.5%). Stent-assisted coiling is safe and effective for the treatment of WNBA with a branch incorporated in the aneurysm base. Despite poor immediate anatomical results, long-term follow-up shows a high rate of progressive thrombosis achieving adequate and stable occlusion in most patients.

  2. Dynamic Contrast-Enhanced Magnetic Resonance Imaging as a Pharmacodynamic Biomarker for Pazopanib in Metastatic Renal Carcinoma.

    PubMed

    Sweis, Randy F; Medved, Milica; Towey, Shannon; Karczmar, Gregory S; Oto, Aytekin; Szmulewitz, Russell Z; O'Donnell, Peter H; Fishkin, Paul; Karrison, Theodore; Stadler, Walter M

    2017-04-01

    Traditional imaging assessment criteria might not correlate well with clinical benefit from vascular endothelial growth factor pathway-directed therapy in metastatic renal cancer. Preclinical data suggest tumor growth is preceded by a rise in K trans level, a parameter derived from dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) that reflects vascular permeability. We thus hypothesized that K trans might be a predictive biomarker for pazopanib. Patients with metastatic renal cancer were treated with pazopanib at 800 mg oral daily until disease progression. MRI of the abdomen and pelvis with a DCE-MRI sequence was obtained at baseline and every 8 weeks. Seventy-three DCE-MRI scans were completed and 66 were technically assessable. Of the 17 patients with at least 1 DCE-MRI scan after the baseline scan, 16 (94%) had a decline in K trans level. Changes in K trans compared with baseline after 1, 8, 16, and 24 weeks were -49%, -65%, -63%, and -53%, respectively (P = .0052, repeated measures analysis of variance). The median K trans nadir occurred at 8 weeks. The median progression-free survival (PFS) was 32.1 weeks. PFS was longer in patients with higher baseline K trans values (P = .036, log rank). Baseline K trans did not reach significance in a Cox proportional hazard model including clinical prognostic index and previous treatments (P = .083). We show that K trans is a pharmacodynamic biomarker for pazopanib therapy in metastatic renal cancer. Because of the small sample size, the predictive capacity of K trans recovery could not be assessed, but baseline K trans correlated with PFS. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. GPHS-RTGs in support of the Cassini RTG Program

    NASA Astrophysics Data System (ADS)

    1995-04-01

    The technical progress achieved during the period 26 Sep. 1994 - 2 Apr. 1995 on Contract DE-AC03-91SF-18852 Radioisotope Thermoelectric Generators and Ancillary Activities is described herein. Monthly technical activity for the period 27 Feb. - 2 Apr. 1995 is included in this progress report. The report addresses tasks, including: spacecraft integration and liaison; engineering support; safety; qualified unicouple production; ETG fabrication, assembly, and test; ground support equipment; RTG shipping and launch support; designs, reviews, and mission applications; project management, quality assurance, reliability, contract changes, CAGO acquisition (operating funds), and CAGO maintenance and repair; and CAGO acquisition (capital funds).

  4. Meta-analysis of the technical performance of an imaging procedure: guidelines and statistical methodology.

    PubMed

    Huang, Erich P; Wang, Xiao-Feng; Choudhury, Kingshuk Roy; McShane, Lisa M; Gönen, Mithat; Ye, Jingjing; Buckler, Andrew J; Kinahan, Paul E; Reeves, Anthony P; Jackson, Edward F; Guimaraes, Alexander R; Zahlmann, Gudrun

    2015-02-01

    Medical imaging serves many roles in patient care and the drug approval process, including assessing treatment response and guiding treatment decisions. These roles often involve a quantitative imaging biomarker, an objectively measured characteristic of the underlying anatomic structure or biochemical process derived from medical images. Before a quantitative imaging biomarker is accepted for use in such roles, the imaging procedure to acquire it must undergo evaluation of its technical performance, which entails assessment of performance metrics such as repeatability and reproducibility of the quantitative imaging biomarker. Ideally, this evaluation will involve quantitative summaries of results from multiple studies to overcome limitations due to the typically small sample sizes of technical performance studies and/or to include a broader range of clinical settings and patient populations. This paper is a review of meta-analysis procedures for such an evaluation, including identification of suitable studies, statistical methodology to evaluate and summarize the performance metrics, and complete and transparent reporting of the results. This review addresses challenges typical of meta-analyses of technical performance, particularly small study sizes, which often causes violations of assumptions underlying standard meta-analysis techniques. Alternative approaches to address these difficulties are also presented; simulation studies indicate that they outperform standard techniques when some studies are small. The meta-analysis procedures presented are also applied to actual [18F]-fluorodeoxyglucose positron emission tomography (FDG-PET) test-retest repeatability data for illustrative purposes. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  5. Meta-analysis of the technical performance of an imaging procedure: Guidelines and statistical methodology

    PubMed Central

    Huang, Erich P; Wang, Xiao-Feng; Choudhury, Kingshuk Roy; McShane, Lisa M; Gönen, Mithat; Ye, Jingjing; Buckler, Andrew J; Kinahan, Paul E; Reeves, Anthony P; Jackson, Edward F; Guimaraes, Alexander R; Zahlmann, Gudrun

    2017-01-01

    Medical imaging serves many roles in patient care and the drug approval process, including assessing treatment response and guiding treatment decisions. These roles often involve a quantitative imaging biomarker, an objectively measured characteristic of the underlying anatomic structure or biochemical process derived from medical images. Before a quantitative imaging biomarker is accepted for use in such roles, the imaging procedure to acquire it must undergo evaluation of its technical performance, which entails assessment of performance metrics such as repeatability and reproducibility of the quantitative imaging biomarker. Ideally, this evaluation will involve quantitative summaries of results from multiple studies to overcome limitations due to the typically small sample sizes of technical performance studies and/or to include a broader range of clinical settings and patient populations. This paper is a review of meta-analysis procedures for such an evaluation, including identification of suitable studies, statistical methodology to evaluate and summarize the performance metrics, and complete and transparent reporting of the results. This review addresses challenges typical of meta-analyses of technical performance, particularly small study sizes, which often causes violations of assumptions underlying standard meta-analysis techniques. Alternative approaches to address these difficulties are also presented; simulation studies indicate that they outperform standard techniques when some studies are small. The meta-analysis procedures presented are also applied to actual [18F]-fluorodeoxyglucose positron emission tomography (FDG-PET) test–retest repeatability data for illustrative purposes. PMID:24872353

  6. Technical Note: DIRART – A software suite for deformable image registration and adaptive radiotherapy research

    PubMed Central

    Yang, Deshan; Brame, Scott; El Naqa, Issam; Aditya, Apte; Wu, Yu; Murty Goddu, S.; Mutic, Sasa; Deasy, Joseph O.; Low, Daniel A.

    2011-01-01

    Purpose: Recent years have witnessed tremendous progress in image guide radiotherapy technology and a growing interest in the possibilities for adapting treatment planning and delivery over the course of treatment. One obstacle faced by the research community has been the lack of a comprehensive open-source software toolkit dedicated for adaptive radiotherapy (ART). To address this need, the authors have developed a software suite called the Deformable Image Registration and Adaptive Radiotherapy Toolkit (DIRART). Methods:DIRART is an open-source toolkit developed in MATLAB. It is designed in an object-oriented style with focus on user-friendliness, features, and flexibility. It contains four classes of DIR algorithms, including the newer inverse consistency algorithms to provide consistent displacement vector field in both directions. It also contains common ART functions, an integrated graphical user interface, a variety of visualization and image-processing features, dose metric analysis functions, and interface routines. These interface routines make DIRART a powerful complement to the Computational Environment for Radiotherapy Research (CERR) and popular image-processing toolkits such as ITK. Results: DIRART provides a set of image processing∕registration algorithms and postprocessing functions to facilitate the development and testing of DIR algorithms. It also offers a good amount of options for DIR results visualization, evaluation, and validation. Conclusions: By exchanging data with treatment planning systems via DICOM-RT files and CERR, and by bringing image registration algorithms closer to radiotherapy applications, DIRART is potentially a convenient and flexible platform that may facilitate ART and DIR research. PMID:21361176

  7. Image, imagination, and reality: on effectiveness of introductory work with vocalists.

    PubMed

    Gullaer, Irene; Walker, Robert; Badin, Pierre; Lamalle, Laurent

    2006-01-01

    Fifty-four sung tokens, each consisting of eight images were generated with the help of magnetic resonance imaging (MRI) technique to demonstrate the work of intrapharyngeal muscles when singing and speaking, and to help the educational process. The MRI images can be used as a part of a visualization feed-back method in vocal education and contribute to creation of proper mental images. The use of visualization (pictures, drafts, graphs, spectra, MRI images, etc.), along with mental images, facilitates simplification and acceleration of the process of understanding and learning how to master the basics of vocal technique, especially in the initial period of study. It is shown that work on muscle development and use of imagination should progress with close interaction between the two. For higher effectiveness and tangible results, mental images used by a vocal pedagogue should correspond to the technical and emotional level of a student. Therefore, mental images have to undertake the same evolution as articulation technique-from simplified and comprehensible to complex and abstract. Our integrated approach suggests continuing the work on muscle development and use of imagination in singing classes, employing the experience of voice-speech teachers. Their exercises are modified using the empirical method and other techniques developed creatively by singing teachers. In this method, sensitivity towards the state of the tissues becomes increasingly refined; students acquire a conscious control over the muscle work, students gain full awareness of both sensation and muscle activity. As a result, a complex of professional conditioned reflexes is being developed. A case study of the New Zealand experience was conducted with groups of Maori and European students. Unique properties and trends in the voices of Maori people are discussed.

  8. The Gap That Can't Go Away: The Catch-22 of Reclassification in Monitoring the Progress of English Learners

    ERIC Educational Resources Information Center

    Saunders, William M.; Marcelletti, David J.

    2013-01-01

    When English Learners (ELs) demonstrate English language proficiency, they are reclassified as Fluent English Proficient (RFEP). Subsequently they are often left out of the analysis of EL progress because they are, technically, no longer ELs. This article examines the effects of including and excluding RFEPs from the analysis of EL progress. Based…

  9. Bone Conduction Communication: Research Progress and Directions

    DTIC Science & Technology

    2017-08-16

    ARL-TR-8096 ● AUG 2017 US Army Research Laboratory Bone Conduction Communication: Research Progress and Directions by Maranda...this report when it is no longer needed. Do not return it to the originator. ARL-TR-8096 ● AUG 2017 US Army Research Laboratory...Bone Conduction Communication: Research Progress and Directions by Maranda McBride North Carolina Agricultural and Technical State University

  10. 25 CFR 30.123 - What is the Bureau's role in assisting Bureau-funded schools to make AYP?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... EDUCATION ADEQUATE YEARLY PROGRESS Failure To Make Adequate Yearly Progress § 30.123 What is the Bureau's...-funded schools to assist them in achieving AYP. This includes technical assistance and other forms of...

  11. 25 CFR 30.123 - What is the Bureau's role in assisting Bureau-funded schools to make AYP?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... EDUCATION ADEQUATE YEARLY PROGRESS Failure To Make Adequate Yearly Progress § 30.123 What is the Bureau's...-funded schools to assist them in achieving AYP. This includes technical assistance and other forms of...

  12. The impact of age on the art of mammography and how to adapt accordingly.

    PubMed

    Lake, B; Cielecki, L; Williams, S; Worrall, C; Metelko, M

    2017-11-01

    Breast cancer is increasingly a disease of the elderly, and combined with the NHS Breast Screening Extension means that more elderly patients are having mammography. Increasing age can make mammography more technically difficult. This is a technical note detailing the results of a local audit which may be of interest due to potential service implications. A retrospective audit of the first year of screening extension of The Shropshire Breast Screening Programme. Aims to collect data on patient demographics and describe the technical adaptations developed in Shropshire. Breast screening extension has increased by 2.5 times the number of women aged 70-74 screened, and doubled the overall numbers of women over 70 screened. Significantly more older patients are being screened to present technical challenges to a screening programme. Data was obtained from a month of screening showed that 29% of patients over 70 needed extra time for positioning. Reasons included 22% difficulty in obtaining adequate positioning and 15% needed a relative to aid with consent. In the Shropshire screening programme different technical adaptations have been developed and are key to ensuring adequate images. These include double appointments, two radiographers, thorough assessment, steeper angles, seated examinations, from-below imaging and pre-planning for subsequent screen. Significantly more older women are having breast screening due to the increasing incidence of breast cancer and the Breast Screening Programme extension. Increasing age can significantly increase time taken for adequate imaging and present technical challenges. Development of technical adaptations to art of mammography is key to achieve adequate images. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  13. Black River Technical College, Exploring America's Communities. Progress Report.

    ERIC Educational Resources Information Center

    Black River Vocational-Technical School, Pocahontas, AR.

    In 1996, Arkansas's Black River Technical College (BRTC) participated in the American Association of Community Colleges' Exploring America's Communities project, which worked to strengthen the teaching and learning of American history, literature, and culture at U.S. community colleges. The proposed centerpiece of BRTC's program is called the…

  14. 40 CFR 40.150 - Evaluation of applications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... Relevancy, coupled with the results of technical review, will provide the basis for funding recommendations... will be reviewed for technical merit by at least one reviewer within EPA and at least two reviewers.... Recommendations for continuation of funding will be based on progress toward the accomplishment of the goals set...

  15. 40 CFR 35.4235 - Are there specific provisions my group's contract(s) must contain?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PROTECTION AGENCY GRANTS AND OTHER FEDERAL ASSISTANCE STATE AND LOCAL ASSISTANCE Grants for Technical Assistance Procuring A Technical Advisor Or Other Contractor with Tag Funds § 35.4235 Are there specific... progress reports; (3) Expenditures; and (4) Commitments indicating their relationship to established costs...

  16. Missouri local technical assistance program at Missouri University of Science and Technology (formerly University of Missouri--Rolla) : annual progress report January-December 2007.

    DOT National Transportation Integrated Search

    2009-02-01

    This annual report is a summary of the activities during 2007 for the Missouri Local Technical Assistance Program (Missouri LTAP), which is located at Missouri University of Science and Technology. The report highlights Missouri LTAPs performance ...

  17. Global Issues in Career and Technical Fields: Internationalizing the Community College Curriculum.

    ERIC Educational Resources Information Center

    Peck, Shirley S.

    1991-01-01

    Presents a rationale for incorporating international content in both general education and career/technical fields, providing a status report on progress to date. Describes four modules prepared by Catonsville Community College (Maryland) instructors for inclusion in criminal justice, air transportation, automotive service, and electronics…

  18. Technical and Vocational Education in Cameroon and Critical Avenues for Development

    ERIC Educational Resources Information Center

    Che, S. Megan

    2007-01-01

    Technical and vocational education (TVE) can influence development and economic progress for post-colonial societies. Some newly independent sub-Saharan African countries attempted curricular transformation that might produce a skilled workforce through widespread access to versions of TVE. In Cameroon, no such post-colonial curricular revolution…

  19. Blurred digital mammography images: an analysis of technical recall and observer detection performance.

    PubMed

    Ma, Wang Kei; Borgen, Rita; Kelly, Judith; Millington, Sara; Hilton, Beverley; Aspin, Rob; Lança, Carla; Hogg, Peter

    2017-03-01

    Blurred images in full-field digital mammography are a problem in the UK Breast Screening Programme. Technical recalls may be due to blurring not being seen on lower resolution monitors used for review. This study assesses the visual detection of blurring on a 2.3-MP monitor and a 5-MP report grade monitor and proposes an observer standard for the visual detection of blurring on a 5-MP reporting grade monitor. 28 observers assessed 120 images for blurring; 20 images had no blurring present, whereas 100 images had blurring imposed through mathematical simulation at 0.2, 0.4, 0.6, 0.8 and 1.0 mm levels of motion. Technical recall rate for both monitors and angular size at each level of motion were calculated. χ 2 tests were used to test whether significant differences in blurring detection existed between 2.3- and 5-MP monitors. The technical recall rate for 2.3- and 5-MP monitors are 20.3% and 9.1%, respectively. The angular size for 0.2- to 1-mm motion varied from 55 to 275 arc s. The minimum amount of motion for visual detection of blurring in this study is 0.4 mm. For 0.2-mm simulated motion, there was no significant difference [χ 2 (1, N = 1095) = 1.61, p = 0.20] in blurring detection between the 2.3- and 5-MP monitors. According to this study, monitors ≤2.3 MP are not suitable for technical review of full-field digital mammography images for the detection of blur. Advances in knowledge: This research proposes the first observer standard for the visual detection of blurring.

  20. Blurred digital mammography images: an analysis of technical recall and observer detection performance

    PubMed Central

    Borgen, Rita; Kelly, Judith; Millington, Sara; Hilton, Beverley; Aspin, Rob; Lança, Carla; Hogg, Peter

    2017-01-01

    Objective: Blurred images in full-field digital mammography are a problem in the UK Breast Screening Programme. Technical recalls may be due to blurring not being seen on lower resolution monitors used for review. This study assesses the visual detection of blurring on a 2.3-MP monitor and a 5-MP report grade monitor and proposes an observer standard for the visual detection of blurring on a 5-MP reporting grade monitor. Methods: 28 observers assessed 120 images for blurring; 20 images had no blurring present, whereas 100 images had blurring imposed through mathematical simulation at 0.2, 0.4, 0.6, 0.8 and 1.0 mm levels of motion. Technical recall rate for both monitors and angular size at each level of motion were calculated. χ2 tests were used to test whether significant differences in blurring detection existed between 2.3- and 5-MP monitors. Results: The technical recall rate for 2.3- and 5-MP monitors are 20.3% and 9.1%, respectively. The angular size for 0.2- to 1-mm motion varied from 55 to 275 arc s. The minimum amount of motion for visual detection of blurring in this study is 0.4 mm. For 0.2-mm simulated motion, there was no significant difference [χ2 (1, N = 1095) = 1.61, p = 0.20] in blurring detection between the 2.3- and 5-MP monitors. Conclusion: According to this study, monitors ≤2.3 MP are not suitable for technical review of full-field digital mammography images for the detection of blur. Advances in knowledge: This research proposes the first observer standard for the visual detection of blurring. PMID:28134567

  1. A multi-institutional survey of interventional radiology for type II endoleaks after endovascular aortic repair: questionnaire results from the Japanese Society of Endoluminal Metallic Stents and Grafts in Japan.

    PubMed

    Ogawa, Yukihisa; Nishimaki, Hiroshi; Osuga, Keigo; Ikeda, Osamu; Hongo, Norio; Iwakoshi, Shinichi; Kawasaki, Ryota; Woodhams, Reiko; Yamaguchi, Masato; Kamiya, Mika; Kanematsu, Masayuki; Honda, Masanori; Kaminou, Toshio; Koizumi, Jun; Kichikawa, Kimihiko

    2016-08-01

    To investigate the current status of interventional radiology (IR) procedures for a type II endoleak (T2EL) in Japan, and to identify the technical aspects that affect treatment results. A retrospective survey was conducted by distributing questionnaires to 25 institutions. The eligibility criteria were endovascular aortic repair (EVAR) performed using commercial stent grafts and IR performed for T2EL between January 2007 and December 2013. Technical success was defined as disappearance of the EL on digital subtraction angiography immediately after embolization, and imaging success was defined as no EL on contrast-enhanced computed tomography within 6 months. Statistical comparisons of the number of involved branches, embolization level, embolic material, and changes in aneurysm size were made between the imaging success and imaging failure groups. The technical and imaging success rates were also compared between the initial therapy and repeat groups. A total of 166 cases were investigated. Initial therapy was performed in 147 cases (88.6 %), with repeat therapy in 19 cases (11.4 %). Transcatheter arterial embolization (TAE) was used most frequently, in 161 cases (97 %), with direct puncture (DP) used in 5 cases (3 %). Both coil embolization for the branches and NBCA embolization for the sac were frequently chosen. The technical success rate was 83.2 % (TAE group), and the imaging success rate was 46.5 % (TAE + DP groups). Branch + sac embolization was performed more frequently in the imaging success group. There was no significant difference in the number of involved branches or embolic material between the imaging success and imaging failure groups. Enlargement of the aneurysm was more frequently seen in the imaging failure group. There were no significant differences in the technical success and imaging success rates between the initial therapy and repeat groups. This is the first report of a multi-institutional questionnaire survey of IR procedures for T2EL after EVAR in Japan that was conducted to determine the current status. Enlargement of aneurysm size after embolization was more frequently seen in the imaging failure group. It is important to embolize both branch and sac to achieve imaging success, regardless of embolic material. Long-term outcomes need to be investigated.

  2. The Image of Career and Technical Education. Practice Application Brief.

    ERIC Educational Resources Information Center

    Brown, Bettina Lankard

    Career and technical education (CTE) instructors can use four strategies to present a new image of CTE as a viable strategy for education and work. Strategy 1 is to give students something to brag about. Three ways to help students see their vocational studies as unique and special opportunities for satisfying and rich experiences are to provide…

  3. Publications of the Jet Propulsion Laboratory, January through December 1974. [deep space network, Apollo project, information theory, and space exploration

    NASA Technical Reports Server (NTRS)

    1975-01-01

    Formalized technical reporting is described and indexed, which resulted from scientific and engineering work performed, or managed, by the Jet Propulsion Laboratory. The five classes of publications included are technical reports, technical memorandums, articles from the bimonthly Deep Space Network Progress Report, special publications, and articles published in the open literature. The publications are indexed by author, subject, and publication type and number.

  4. Impact of Nuclear Laboratory Personnel Credentials & Continuing Education on Nuclear Cardiology Laboratory Quality Operations.

    PubMed

    Malhotra, Saurabh; Sobieraj, Diana M; Mann, April; Parker, Matthew W

    2017-12-22

    Background/Objectives: The specific credentials and continuing education (CME/CE) of nuclear cardiology laboratory medical and technical staff are important factors in the delivery of quality imaging services that have not been systematically evaluated. Methods: Nuclear cardiology accreditation application data from the Intersocietal Accreditation Commission (IAC) was used to characterize facilities performing myocardial perfusion imaging by setting, size, previous accreditation and credentials of the medical and technical staff. Credentials and CME/CE were compared against initial accreditation decisions (grant or delay) using multivariable logistic regression. Results: Complete data were available for 1913 nuclear cardiology laboratories from 2011-2014. Laboratories with initial positive accreditation decisions had a greater prevalence of Certification Board in Nuclear Cardiology (CBNC) certified medical directors and specialty credentialed technical directors. Certification and credentials of the medical and technical directors, respectively, staff CME/CE compliance, and assistance of a consultant with the application were positively associated with accreditation decisions. Conclusion: Nuclear cardiology laboratories directed by CBNC-certified physicians and NCT- or PET-credentialed technologists were less likely to receive delay decisions for MPI. CME/CE compliance of both the medical and technical directors was associated with accreditation decision. Medical and technical directors' years of experience were not associated with accreditation decision. Copyright © 2017 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  5. Validating new diagnostic imaging criteria for primary progressive aphasia via anatomical likelihood estimation meta-analyses.

    PubMed

    Bisenius, S; Neumann, J; Schroeter, M L

    2016-04-01

    Recently, diagnostic clinical and imaging criteria for primary progressive aphasia (PPA) have been revised by an international consortium (Gorno-Tempini et al. Neurology 2011;76:1006-14). The aim of this study was to validate the specificity of the new imaging criteria and investigate whether different imaging modalities [magnetic resonance imaging (MRI) and fluorodeoxyglucose positron emission tomography (FDG-PET)] require different diagnostic subtype-specific imaging criteria. Anatomical likelihood estimation meta-analyses were conducted for PPA subtypes across a large cohort of 396 patients: firstly, across MRI studies for each of the three PPA subtypes followed by conjunction and subtraction analyses to investigate the specificity, and, secondly, by comparing results across MRI vs. FDG-PET studies in semantic dementia and progressive nonfluent aphasia. Semantic dementia showed atrophy in temporal, fusiform, parahippocampal gyri, hippocampus, and amygdala, progressive nonfluent aphasia in left putamen, insula, middle/superior temporal, precentral, and frontal gyri, logopenic progressive aphasia in middle/superior temporal, supramarginal, and dorsal posterior cingulate gyri. Results of the disease-specific meta-analyses across MRI studies were disjunct. Similarly, atrophic and hypometabolic brain networks were regionally dissociated in both semantic dementia and progressive nonfluent aphasia. In conclusion, meta-analyses support the specificity of new diagnostic imaging criteria for PPA and suggest that they should be specified for each imaging modality separately. © 2016 EAN.

  6. The use of near-infrared fluorescence imaging in endocrine surgical procedures.

    PubMed

    Kahramangil, Bora; Berber, Eren

    2017-06-01

    Near-infrared fluorescence imaging in endocrine surgery is a new, yet highly investigated area. It involves indocyanine green use as well as parathyroid autofluorescence. Several groups have described their technique and reported on the observed utility. However, there is no consensus on technical details. Furthermore, the correlation between intraoperative findings and postoperative outcomes is unclear. With this study, we aim to review the current literature on fluorescence imaging and share our insights on technical details. © 2017 Wiley Periodicals, Inc.

  7. Evaluation of a Delay-Doppler Imaging Algorithm Based on the Wigner-Ville Distribution

    DTIC Science & Technology

    1989-10-18

    exchanging the frequency and time variables. 2.3 PROPERTIES OF THE WIGNER - VILLE DISTRIBUTION A partial list of the properties of the WVD is provided...ESD-TH-89-163 N Technical Report (N R55 00 Lfl Evaluation of a Delay-Doppler Imaging Algorithm Based on the Wigner - Ville Distribution K.I. Schultz 18...DOPPLER IMAGING ALGORITHM BASED ON THE WIGNER - VILLE DISTRIBUTION K.I. SCHULTZ Group 52 TECHNICAL REPORT 855 18 OCTOBER 1989 Approved for public release

  8. Technical adequacy of growth estimates from a computer adaptive test: Implications for progress monitoring.

    PubMed

    Van Norman, Ethan R; Nelson, Peter M; Parker, David C

    2017-09-01

    Computer adaptive tests (CATs) hold promise to monitor student progress within multitiered systems of support. However, the relationship between how long and how often data are collected and the technical adequacy of growth estimates from CATs has not been explored. Given CAT administration times, it is important to identify optimal data collection schedules to minimize missed instructional time. We used simulation methodology to investigate how the duration and frequency of data collection influenced the reliability, validity, and precision of growth estimates from a math CAT. A progress monitoring dataset of 746 Grade 4, 664 Grade 5, and 400 Grade 6 students from 40 schools in the upper Midwest was used to generate model parameters. Across grades, 53% of students were female and 53% were White. Grade level was not as influential as the duration and frequency of data collection on the technical adequacy of growth estimates. Low-stakes decisions were possible after 14-18 weeks when data were collected weekly (420-540 min of assessment), 20-24 weeks when collected every other week (300-360 min of assessment), and 20-28 weeks (150-210 min of assessment) when data were collected once a month, depending on student grade level. The validity and precision of growth estimates improved when the duration and frequency of progress monitoring increased. Given the amount of time required to obtain technically adequate growth estimates in the present study, results highlight the importance of weighing the potential costs of missed instructional time relative to other types of assessments, such as curriculum-based measures. Implications for practice, research, as well as future directions are also discussed. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  9. 24 CFR 1006.430 - Corrective and remedial action.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... plan; (3) Made substantial progress in carrying out its program and achieving its quantifiable goals as... to submit progress schedules for completing activities or complying with the requirements of the Act... appropriate technical assistance using existing grant funds or other available resources to overcome the...

  10. Technical Pitfall in 68Ga-Prostate Specific Membrane Antigen Imaging: Altered Biodistribution Caused by Free 68Ga-Citrate Due to Radiolysis Showing Increased Vascular Activity.

    PubMed

    Hod, Nir; Anconina, Reut; Levin, Daniel; Ezroh Kazap, Dina; Lantsberg, Sophie

    2018-06-01

    As with any new molecular imaging modality, accurate characterization of abnormalities on Ga-PSMA PET/CT imaging can be accomplished only if one is aware of the normal distribution pattern, physiological variants, and potential sources of false imaging findings. Altered biodistribution can have a significant impact on scan interpretation. Presented here is a rare case in which radiopharmaceutical radiolysis occurred causing excessive free Ga-citrate showing as an increased vascular activity. As Ga-PSMA PET/CT imaging is a relatively new imaging technique, it is important to be aware of such a potential technical pitfall in clinical practice in order to prevent scan misinterpretation.

  11. Synchrotron topography project. Progress report, January 20, 1982-October 20, 1982

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bilello, J.C.; Chen, H.; Hmelo, A.B.

    1982-01-01

    The collaborators have participated in the Synchrotron Topography Project (STP) which has designed and developed instrumentation for an x-ray topography station at the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory (BNL). The two principle instruments constructed consist of a White Beam Camera (WBC) and a Multiple Crystal Camera (MCC) with high planar collimation and wide area image coverage. It is possible to perform in-situ studies in a versatile environmental chamber equipped with a miniature mechanical testing stage for both the WBC and MCC systems. Real-time video imaging plus a rapid feed cassette holder for high resolution photographic platesmore » are available for recording topographs. Provisions are made for other types of photon detection as well as spectroscopy. The facilities for the entire station have been designed for remote operation using a LSI-11/23 plus suitable interfacing. These instruments will be described briefly and the current status of the program will be reviewed. The Appendix of this report presents titles, authors and abstracts of other technical work associated with this project during the current period.« less

  12. Imaging Transcriptional Regulation of Eukaryotic mRNA Genes: Advances and Outlook.

    PubMed

    Yao, Jie

    2017-01-06

    Regulation of eukaryotic transcription in vivo occurs at distinct stages. Previous research has identified many active or repressive transcription factors (TFs) and core transcription components and studied their functions in vitro and in vivo. Nonetheless, how individual TFs act in concert to regulate mRNA gene expression in a single cell remains poorly understood. Direct observation of TF assembly and disassembly and various biochemical reactions during transcription of a single-copy gene in vivo is the ideal approach to study this problem. Research in this area requires developing novel techniques for single-cell transcription imaging and integrating imaging studies into understanding the molecular biology of transcription. In the past decade, advanced cell imaging has enabled unprecedented capabilities to visualize individual TF molecules, to track single transcription sites, and to detect individual mRNA in fixed and living cells. These studies have raised several novel insights on transcriptional regulation such as the "hit-and-run" model and transcription bursting that could not be obtained by in vitro biochemistry analysis. At this point, the key question is how to achieve deeper understandings or discover novel mechanisms of eukaryotic transcriptional regulation by imaging transcription in single cells. Meanwhile, further technical advancements are likely required for visualizing distinct kinetic steps of transcription on a single-copy gene in vivo. This review article summarizes recent progress in the field and describes the challenges and opportunities ahead. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Progress and Prospect: A Report Submitted to the Governing Board of the Maricopa County Community College District.

    ERIC Educational Resources Information Center

    Maricopa Technical Community Coll., Phoenix, AZ.

    This two-part report seeks to outline the progress made to date by Maricopa Technical Community College (MTCC) through its first eight years of operation, and to recommend specific actions which might be taken in the future by the college to insure its continued progress and response to community needs in light of constraints on funding and…

  14. An efficient system for reliably transmitting image and video data over low bit rate noisy channels

    NASA Technical Reports Server (NTRS)

    Costello, Daniel J., Jr.; Huang, Y. F.; Stevenson, Robert L.

    1994-01-01

    This research project is intended to develop an efficient system for reliably transmitting image and video data over low bit rate noisy channels. The basic ideas behind the proposed approach are the following: employ statistical-based image modeling to facilitate pre- and post-processing and error detection, use spare redundancy that the source compression did not remove to add robustness, and implement coded modulation to improve bandwidth efficiency and noise rejection. Over the last six months, progress has been made on various aspects of the project. Through our studies of the integrated system, a list-based iterative Trellis decoder has been developed. The decoder accepts feedback from a post-processor which can detect channel errors in the reconstructed image. The error detection is based on the Huber Markov random field image model for the compressed image. The compression scheme used here is that of JPEG (Joint Photographic Experts Group). Experiments were performed and the results are quite encouraging. The principal ideas here are extendable to other compression techniques. In addition, research was also performed on unequal error protection channel coding, subband vector quantization as a means of source coding, and post processing for reducing coding artifacts. Our studies on unequal error protection (UEP) coding for image transmission focused on examining the properties of the UEP capabilities of convolutional codes. The investigation of subband vector quantization employed a wavelet transform with special emphasis on exploiting interband redundancy. The outcome of this investigation included the development of three algorithms for subband vector quantization. The reduction of transform coding artifacts was studied with the aid of a non-Gaussian Markov random field model. This results in improved image decompression. These studies are summarized and the technical papers included in the appendices.

  15. Imaging windows for long-term intravital imaging: General overview and technical insights.

    PubMed

    Alieva, Maria; Ritsma, Laila; Giedt, Randy J; Weissleder, Ralph; van Rheenen, Jacco

    2014-01-01

    Intravital microscopy is increasingly used to visualize and quantitate dynamic biological processes at the (sub)cellular level in live animals. By visualizing tissues through imaging windows, individual cells (e.g., cancer, host, or stem cells) can be tracked and studied over a time-span of days to months. Several imaging windows have been developed to access tissues including the brain, superficial fascia, mammary glands, liver, kidney, pancreas, and small intestine among others. Here, we review the development of imaging windows and compare the most commonly used long-term imaging windows for cancer biology: the cranial imaging window, the dorsal skin fold chamber, the mammary imaging window, and the abdominal imaging window. Moreover, we provide technical details, considerations, and trouble-shooting tips on the surgical procedures and microscopy setups for each imaging window and explain different strategies to assure imaging of the same area over multiple imaging sessions. This review aims to be a useful resource for establishing the long-term intravital imaging procedure.

  16. Optical fiber sensors for materials and structures characterization

    NASA Technical Reports Server (NTRS)

    Lindner, D. K.; Claus, R. O.

    1991-01-01

    The final technical report on Optical Fiber Sensors for Materials and Structures Characterization, covering the period August 1990 through August 1991 is presented. Research programs in the following technical areas are described; sapphire optical fiber sensors; vibration analysis using two-mode elliptical core fibers and sensors; extrinsic Fabry-Perot interferometer development; and coatings for fluorescent-based sensor. Research progress in each of these areas was substantial, as evidenced by the technical publications which are included as appendices.

  17. 44 CFR 206.437 - State administrative plan.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... requests for advances of funds and reimbursement; (vii) Monitor and evaluate the progress and completion of... technical assistance as required to subgrantee(s); (xi) Comply with the administrative and audit requirements of 44 CFR parts 13 and 206; (xii) Provide quarterly progress reports to the Regional Administrator...

  18. 25 CFR 30.122 - Must the Bureau assist a school it identified for school improvement, corrective action, or...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., DEPARTMENT OF THE INTERIOR EDUCATION ADEQUATE YEARLY PROGRESS Failure To Make Adequate Yearly Progress § 30... restructuring, the Bureau must provide technical or other assistance described in 20 U.S.C. 6316(b)(4) and 20 U...

  19. 44 CFR 206.437 - State administrative plan.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... requests for advances of funds and reimbursement; (vii) Monitor and evaluate the progress and completion of... technical assistance as required to subgrantee(s); (xi) Comply with the administrative and audit requirements of 44 CFR parts 13 and 206; (xii) Provide quarterly progress reports to the Regional Administrator...

  20. 25 CFR 30.122 - Must the Bureau assist a school it identified for school improvement, corrective action, or...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., DEPARTMENT OF THE INTERIOR EDUCATION ADEQUATE YEARLY PROGRESS Failure To Make Adequate Yearly Progress § 30... restructuring, the Bureau must provide technical or other assistance described in 20 U.S.C. 6316(b)(4) and 20 U...

  1. Assessment Program Technical Progress Report, 1997-1998.

    ERIC Educational Resources Information Center

    Eickmeyer, Barbara; Hill, Stephen

    This Assessment Program Progress Report (APPR) records the institutional activities that have taken place at Coconino Community College (CCC) during the 1997-98 academic year. It presents models, timelines, accomplishments, and opportunities for improvement in the assessment practices at CCC. Implementation and outcomes information is included for…

  2. Diagnostic Efficiency of easyCBM[R] Math: Oregon. Technical Report #1009

    ERIC Educational Resources Information Center

    Anderson, Daniel; Alonzo, Julie; Tindal, Gerald

    2010-01-01

    The easyCBM[R] assessment system is an online benchmark and progress monitoring assessment system designed for use within a response to intervention framework. Educators using easyCBM[R] are often interested in using the results to predict students' state test performance. In the following technical document, we report diagnostic efficiency…

  3. Longitudinal Surveys of Australian Youth (LSAY) 2009 Cohort: Wave 2 (2010)-- Questionnaire. Technical Report 71A

    ERIC Educational Resources Information Center

    National Centre for Vocational Education Research (NCVER), 2012

    2012-01-01

    The Longitudinal Surveys of Australian Youth (LSAY) program studies the progress of several groups of young Australians as they move from school into post-secondary education and work. This technical paper contains the questionnaire for the LSAY 2009 cohort Wave 2 (2010) data set.

  4. Longitudinal Surveys of Australian Youth (LSAY) 2009 Cohort: Wave 3 (2011)--Questionnaire. Technical Report 72A

    ERIC Educational Resources Information Center

    National Centre for Vocational Education Research (NCVER), 2012

    2012-01-01

    The Longitudinal Surveys of Australian Youth (LSAY) program studies the progress of several groups of young Australians as they move from school into post-secondary education and work. This technical paper contains the questionnaire for the LSAY 2009 cohort Wave 3 (2011) data set.

  5. Educational Reform and the World of Work: Italy

    ERIC Educational Resources Information Center

    von Blumenthal, Viktor

    1977-01-01

    One of a four-issue series on educational reform and the world of work in Europe, this issue discusses educational planning and secondary school reform in Italy. Topics discussed include planning and research in vocational-technical education, and the relation between acquisition of specific skills and scientific and technical progress. (Author/DB)

  6. Longitudinal Surveys of Australian Youth (LSAY) 2009 Cohort: Wave 2 (2010)--Frequency Tables. Technical Report 71B

    ERIC Educational Resources Information Center

    National Centre for Vocational Education Research (NCVER), 2012

    2012-01-01

    The Longitudinal Surveys of Australian Youth (LSAY) program studies the progress of several groups of young Australians as they move from school into post-secondary education and work. This technical paper contains the frequency tables for the LSAY 2009 cohort Wave 2 (2010) data set.

  7. Higher Education in Kazakhstan and the Bologna Process

    ERIC Educational Resources Information Center

    Piven, G.; Pak, I.U.

    2006-01-01

    The constantly rising role of higher education in the twenty-first century goes hand in hand with scientific and technical progress and the global technologization of the developed countries of the world. A country's level of technical and technological development determines its economic condition, its national security, and its role in the world…

  8. A State Response to Indian Vocational Education.

    ERIC Educational Resources Information Center

    McConnell, Bruce

    In 1977 more than 500 Native Americans attended Wisconsin's vocational, technical and adult schools located in the state's 16 vocational-technical districts. While many problems still lack a clear identification and many new programs are needed to meet the needs of Native Americans, a great deal of progress has been made. A group of four Indians…

  9. Analytical Chemistry Division. Annual progress report for period ending December 31, 1980

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lyon, W.S.

    1981-05-01

    This report is divided into: analytical methodology; mass and emission spectrometry; technical support; bio/organic analysis; nuclear and radiochemical analysis; quality assurance, safety, and tabulation of analyses; supplementary activities; and presentation of research results. Separate abstracts were prepared for the technical support, bio/organic analysis, and nuclear and radiochemical analysis. (DLC)

  10. Scientific and Technical Information Transfer for Education (STITE). Research Report No. 2.

    ERIC Educational Resources Information Center

    Zunde, Pranas

    STITE (Scientific and Technical Information Transfer for Education) is basically a system to interface between science information and the science learner. As such STITE acts as a link between STIC (Science and Technology Infromation Centers) and LIS (Learning Information Systems). In this second progress report the internal knowledge of STITE is…

  11. Mathematics Technical Report: Exercise Volume. National Assessment of Educational Progress. Report No. 04-MA-20.

    ERIC Educational Resources Information Center

    Education Commission of the States, Denver, CO. National Assessment of Educational Progress.

    Included in Chapter 1 of this report are background information on the 1972-73 mathematics assessment; details of the computational formulas used in reporting results; and explanations of the technical documentation, exercise presentation, documentation pages, scoring guides, and data tables for released and unreleased exercises. The remainder of…

  12. Experimentation with Computer-Assisted Instruction in Technical Education. Semi-Annual Progress Report.

    ERIC Educational Resources Information Center

    Mitzel, Harold E.; Brandon, George L.

    A series of five reports is presented which describes the activities carried out by the Pennsylvania State University group engaged in research in computer-assisted instruction (CAI) in vocational-technical education. The reports cover the period January 1968-June 1968 and deal with: 1) prior knowledge and individualized instruction; 2) numerical…

  13. Do failures in non-technical skills contribute to fatal medical accidents in Japan? A review of the 2010–2013 national accident reports

    PubMed Central

    Uramatsu, Masashi; Fujisawa, Yoshikazu; Mizuno, Shinya; Souma, Takahiro; Komatsubara, Akinori; Miki, Tamotsu

    2017-01-01

    Objectives We sought to clarify how large a proportion of fatal medical accidents can be considered to be caused by poor non-technical skills, and to support development of a policy to reduce number of such accidents by making recommendations about possible training requirements. Design Summaries of reports of fatal medical accidents, published by the Japan Medical Safety Research Organization, were reviewed individually. Three experienced clinicians and one patient safety expert conducted the reviews to determine the cause of death. Views of the patient safety expert were given additional weight in the overall determination. Setting A total of 73 summary reports of fatal medical accidents were reviewed. These reports had been submitted by healthcare organisations across Japan to the Japan Medical Safety Research Organization between April 2010 and March 2013. Primary and secondary outcome measures The cause of death in fatal medical accidents, categorised into technical skills, non-technical skills and inevitable progress of disease were evaluated. Non-technical skills were further subdivided into situation awareness, decision making, communication, team working, leadership, managing stress and coping with fatigue. Results Overall, the cause of death was identified as non-technical skills in 34 cases (46.6%), disease progression in 33 cases (45.2%) and technical skills in two cases (5.5%). In two cases, no consensual determination could be achieved. Further categorisation of cases of non-technical skills were identified as 14 cases (41.2%) of problems with situation awareness, eight (23.5%) with team working and three (8.8%) with decision making. These three subcategories, or combinations of them, were identified as the cause of death in 33 cases (97.1%). Conclusions Poor non-technical skills were considered to be a significant cause of adverse events in nearly half of the fatal medical accidents examined. Improving non-technical skills may be effective for reducing accidents, and training in particular subcategories of non-technical skills may be especially relevant. PMID:28209605

  14. Geospatial Analysis | Energy Analysis | NREL

    Science.gov Websites

    products and tools. Image of a triangle divided into sections called Market, Economic, Technical, and Featured Study U.S. Renewable Energy Technical Potentials: A GIS-Based Analysis summarizes the achievable energy generation, or technical potential, of specific renewable energy technologies given system

  15. A Review of Adaptive Optics Optical Coherence Tomography: Technical Advances, Scientific Applications, and the Future

    PubMed Central

    Jonnal, Ravi S.; Kocaoglu, Omer P.; Zawadzki, Robert J.; Liu, Zhuolin; Miller, Donald T.; Werner, John S.

    2016-01-01

    Purpose Optical coherence tomography (OCT) has enabled “virtual biopsy” of the living human retina, revolutionizing both basic retina research and clinical practice over the past 25 years. For most of those years, in parallel, adaptive optics (AO) has been used to improve the transverse resolution of ophthalmoscopes to foster in vivo study of the retina at the microscopic level. Here, we review work done over the last 15 years to combine the microscopic transverse resolution of AO with the microscopic axial resolution of OCT, building AO-OCT systems with the highest three-dimensional resolution of any existing retinal imaging modality. Methods We surveyed the literature to identify the most influential antecedent work, important milestones in the development of AO-OCT technology, its applications that have yielded new knowledge, research areas into which it may productively expand, and nascent applications that have the potential to grow. Results Initial efforts focused on demonstrating three-dimensional resolution. Since then, many improvements have been made in resolution and speed, as well as other enhancements of acquisition and postprocessing techniques. Progress on these fronts has produced numerous discoveries about the anatomy, function, and optical properties of the retina. Conclusions Adaptive optics OCT continues to evolve technically and to contribute to our basic and clinical knowledge of the retina. Due to its capacity to reveal cellular and microscopic detail invisible to clinical OCT systems, it is an ideal companion to those instruments and has the demonstrable potential to produce images that can guide the interpretation of clinical findings. PMID:27409507

  16. A progressive data compression scheme based upon adaptive transform coding: Mixture block coding of natural images

    NASA Technical Reports Server (NTRS)

    Rost, Martin C.; Sayood, Khalid

    1991-01-01

    A method for efficiently coding natural images using a vector-quantized variable-blocksized transform source coder is presented. The method, mixture block coding (MBC), incorporates variable-rate coding by using a mixture of discrete cosine transform (DCT) source coders. Which coders are selected to code any given image region is made through a threshold driven distortion criterion. In this paper, MBC is used in two different applications. The base method is concerned with single-pass low-rate image data compression. The second is a natural extension of the base method which allows for low-rate progressive transmission (PT). Since the base method adapts easily to progressive coding, it offers the aesthetic advantage of progressive coding without incorporating extensive channel overhead. Image compression rates of approximately 0.5 bit/pel are demonstrated for both monochrome and color images.

  17. An illustrative overview of semi-quantitative MRI scoring of knee osteoarthritis: lessons learned from longitudinal observational studies.

    PubMed

    Roemer, F W; Hunter, D J; Crema, M D; Kwoh, C K; Ochoa-Albiztegui, E; Guermazi, A

    2016-02-01

    To introduce the most popular magnetic resonance imaging (MRI) osteoarthritis (OA) semi-quantitative (SQ) scoring systems to a broader audience with a focus on the most commonly applied scores, i.e., the MOAKS and WORMS system and illustrate similarities and differences. While the main structure and methodology of each scoring system are publicly available, the core of this overview will be an illustrative imaging atlas section including image examples from multiple OA studies applying MRI in regard to different features assessed, show specific examples of different grades and point out pitfalls and specifics of SQ assessment including artifacts, blinding to time point of acquisition and within-grade evaluation. Similarities and differences between different scoring systems are presented. Technical considerations are followed by a brief description of the most commonly utilized SQ scoring systems including their responsiveness and reliability. The second part is comprised of the atlas section presenting illustrative image examples. Evidence suggests that SQ assessment of OA by expert MRI readers is valid, reliable and responsive, which helps investigators to understand the natural history of this complex disease and to evaluate potential new drugs in OA clinical trials. Researchers have to be aware of the differences and specifics of the different systems to be able to engage in imaging assessment and interpretation of imaging-based data. SQ scoring has enabled us to explain associations of structural tissue damage with clinical manifestations of the disease and with morphological alterations thought to represent disease progression. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  18. An illustrative overview of semi-quantitative MRI scoring of knee osteoarthritis: Lessons learned from longitudinal observational studies

    PubMed Central

    Roemer, Frank W.; Hunter, David J.; Crema, Michel D.; Kwoh, C. Kent; Ochoa-Albiztegui, Elena; Guermazi, Ali

    2015-01-01

    Objective To introduce the most popular magnetic resonance imaging (MRI) osteoarthritis (OA) semi-quantitative (SQ) scoring systems to a broader audience with a focus on the most commonly applied scores, i.e. the MOAKS and WORMS system and illustrate similarities and differences. Design While the main structure and methodology of each scoring system are publicly available, the core of this overview will be an illustrative imaging atlas section including image examples from multiple osteoarthritis studies applying MRI in regard to different features assessed, show specific examples of different grades and point out pitfalls and specifics of SQ assessment including artifacts, blinding to time point of acquisition and within-grade evaluation. Results Similarities and differences between different scoring systems are presented. Technical considerations are followed by a brief description of the most commonly utilized SQ scoring systems including their responsiveness and reliability. The second part is comprised of the atlas section presenting illustrative image examples. Conclusions Evidence suggests that SQ assessment of OA by expert MRI readers is valid, reliable and responsive, which helps investigators to understand the natural history of this complex disease and to evaluate potential new drugs in OA clinical trials. Researchers have to be aware of the differences and specifics of the different systems to be able to engage in imaging assessment and interpretation of imaging-based data. SQ scoring has enabled us to explain associations of structural tissue damage with clinical manifestations of the disease and with morphological alterations thought to represent disease progression. PMID:26318656

  19. Towards local estimation of emphysema progression using image registration

    NASA Astrophysics Data System (ADS)

    Staring, M.; Bakker, M. E.; Shamonin, D. P.; Stolk, J.; Reiber, J. H. C.; Stoel, B. C.

    2009-02-01

    Progression measurement of emphysema is required to evaluate the health condition of a patient and the effect of drugs. To locally estimate progression we use image registration, which allows for volume correction using the determinant of the Jacobian of the transformation. We introduce an adaptation of the so-called sponge model that circumvents its constant-mass assumption. Preliminary results from CT scans of a lung phantom and from CT data sets of three patients suggest that image registration may be a suitable method to locally estimate emphysema progression.

  20. An accessible, scalable ecosystem for enabling and sharing diverse mass spectrometry imaging analyses

    DOE PAGES

    Fischer, Curt R.; Ruebel, Oliver; Bowen, Benjamin P.

    2015-09-11

    Mass spectrometry imaging (MSI) is used in an increasing number of biological applications. Typical MSI datasets contain unique, high-resolution mass spectra from tens of thousands of spatial locations, resulting in raw data sizes of tens of gigabytes per sample. In this paper, we review technical progress that is enabling new biological applications and that is driving an increase in the complexity and size of MSI data. Handling such data often requires specialized computational infrastructure, software, and expertise. OpenMSI, our recently described platform, makes it easy to explore and share MSI datasets via the web – even when larger than 50more » GB. Here we describe the integration of OpenMSI with IPython notebooks for transparent, sharable, and replicable MSI research. An advantage of this approach is that users do not have to share raw data along with analyses; instead, data is retrieved via OpenMSI's web API. The IPython notebook interface provides a low-barrier entry point for data manipulation that is accessible for scientists without extensive computational training. Via these notebooks, analyses can be easily shared without requiring any data movement. We provide example notebooks for several common MSI analysis types including data normalization, plotting, clustering, and classification, and image registration.« less

  1. Imaging in multiple sclerosis: A new spin on lesions.

    PubMed

    Bou Fakhredin, Rayan; Saade, Charbel; Kerek, Racha; El-Jamal, Lara; Khoury, Samia J; El-Merhi, Fadi

    2016-10-01

    This article evaluates the most relevant state-of-the-art magnetic resonance (MR) techniques that are clinically available to investigate multiple sclerosis (MS). The presence of hypo- and hyperintense lesions on T1- and T2-weighted magnetic resonance imaging (MRI) sequences in white matter (WM) is a common finding that is occasionally a diagnostic challenge for the radiologist. The technical requirements and how they may help to understand, classify or follow-up these pathologies are briefly summarized. The gold standard for MS diagnosis is pathological correlation. Yet due to limited availability of biopsy and autopsy material, there is a high demand for imaging as a diagnostic as well as prognostic indicator. With the progress in MRI during the last decade, MRI now plays a leading role in the diagnosis and follow-up of MS. A number of correlative pathological and MR studies have helped to define pathological substrates of MS in focal lesions and normal appearing white matter (NAWM). Vascular spaces mimicking MS lesions have been minimized by the enhanced differentiation of WM and grey (GM) matter parenchyma. The aim of this article is to enhance the current understanding of histopathology and radiological characteristics of MS lesions in space and time. © 2016 The Royal Australian and New Zealand College of Radiologists.

  2. Utility of double-contrast multi-detector CT scans to assess cartilage thickness after tibial plafond fracture

    PubMed Central

    Thomas, Thaddeus P.; Van Hofwegen, Christopher J.; Anderson, Donald D.; Brown, Thomas D.; Marsh, J. Lawrence

    2010-01-01

    The pathophysiology of post-traumatic osteoarthritis (PTOA) after intra-articular fractures is poorly understood. Pursuit of a better understanding of this disease is complicated by inability to accurately monitor its onset, progression and severity. Common radiographic methods used to assess PTOA do not provide sufficient image quality for precise cartilage measurements. Double-contrast MDCT is an alternative method that may be useful, since it produces high-quality images in normal ankles. The purpose of this study was to assess this technique’s performance in assessing cartilage maintenance in ankles with an intra-articular fracture. Thirty-six tibial plafond fractures were followed over two years, with thirty-one MDCTs being obtained four months after injury, and twenty-two MDCTs after two years. Unfortunately, clinical results with this technique were unreliable due to pathology (presumed arthrofibrosis) and technical problems (pooling of contrast). The arthrofibrosis that developed in many patients inhibited proper joint access and contrast infiltration, although high-quality images were obtained in eleven patients. In this patient subset, in which focal regions of cartilage degeneration could be visualized, thickness could be measured with a high degree of fidelity. While thus useful in selected instances, double-contrast MDCT was too unreliable to be recommended to assess these particular types of injuries. PMID:20634971

  3. An accessible, scalable ecosystem for enabling and sharing diverse mass spectrometry imaging analyses.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fischer, CR; Ruebel, O; Bowen, BP

    Mass spectrometry imaging (MSI) is used in an increasing number of biological applications. Typical MSI datasets contain unique, high-resolution mass spectra from tens of thousands of spatial locations, resulting in raw data sizes of tens of gigabytes per sample. In this paper, we review technical progress that is enabling new biological applications and that is driving an increase in the complexity and size of MSI data. Handling such data often requires specialized computational infrastructure, software, and expertise. OpenMSI, our recently described platform, makes it easy to explore and share MSI datasets via the web - even when larger than 50 GB.more » Here we describe the integration of OpenMSI with IPython notebooks for transparent, sharable, and replicable MSI research. An advantage of this approach is that users do not have to share raw data along with analyses; instead, data is retrieved via OpenMSI's web API. The IPython notebook interface provides a low-barrier entry point for data manipulation that is accessible for scientists without extensive computational training. Via these notebooks, analyses can be easily shared without requiring any data movement. We provide example notebooks for several common MSI analysis types including data normalization, plotting, clustering, and classification, and image registration.« less

  4. An accessible, scalable ecosystem for enabling and sharing diverse mass spectrometry imaging analyses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fischer, Curt R.; Ruebel, Oliver; Bowen, Benjamin P.

    Mass spectrometry imaging (MSI) is used in an increasing number of biological applications. Typical MSI datasets contain unique, high-resolution mass spectra from tens of thousands of spatial locations, resulting in raw data sizes of tens of gigabytes per sample. In this paper, we review technical progress that is enabling new biological applications and that is driving an increase in the complexity and size of MSI data. Handling such data often requires specialized computational infrastructure, software, and expertise. OpenMSI, our recently described platform, makes it easy to explore and share MSI datasets via the web – even when larger than 50more » GB. Here we describe the integration of OpenMSI with IPython notebooks for transparent, sharable, and replicable MSI research. An advantage of this approach is that users do not have to share raw data along with analyses; instead, data is retrieved via OpenMSI's web API. The IPython notebook interface provides a low-barrier entry point for data manipulation that is accessible for scientists without extensive computational training. Via these notebooks, analyses can be easily shared without requiring any data movement. We provide example notebooks for several common MSI analysis types including data normalization, plotting, clustering, and classification, and image registration.« less

  5. Therapy response assessment after radioembolization of patients with hepatocellular carcinoma--comparison of MR imaging with gadolinium ethoxybenzyl diethylenetriamine penta-acetic acid and gadobutrol.

    PubMed

    Schelhorn, Juliane; Best, Jan; Reinboldt, Marcus P; Gerken, Guido; Ruhlmann, Marcus; Lauenstein, Thomas C; Antoch, Gerald; Kinner, Sonja

    2015-07-01

    To compare the utility of gadolinium ethoxybenzyl diethylenetriamine penta-acetic acid (Gd-EOB-DTPA), a liver-specific magnetic resonance (MR) imaging contrast agent, versus gadobutrol for treatment response evaluation of hepatocellular carcinoma (HCC) after radioembolization. This prospective study included 50 patients with HCC undergoing radioembolization. All patients underwent contrast-enhanced computed tomography (CT) and MR imaging with gadobutrol and Gd-EOB-DTPA on 2 consecutive days before radioembolization and 30 days, 90 days, 180 days, and 270 days after radioembolization. The standard of reference indicating tumor progression was CT combined with either α-fetoprotein or γ-glutamyltransferase. Gadobutrol-enhanced MR imaging, Gd-EOB-DTPA-enhanced MR imaging without late phase imaging (Gd-EOB-DTPA-), and Gd-EOB-DTPA-enhanced MR imaging with late phase imaging (Gd-EOB-DTPA+) were evaluated by 2 radiologists in consensus using a 4-point scale: 1 = definitely no tumor progression; 2 = probably no tumor progression; 3 = probably tumor progression; 4 = definitely tumor progression. Diagnostic accuracy was assessed with receiver operating characteristic analysis. Tumor progression was detected in 14 of 82 study visits according to the reference standard. Pairwise comparison of the area under the curve showed a tendency toward a larger area under the curve for Gd-EOB-DTPA+ compared with gadobutrol (P = .056). Sensitivity and specificity were higher in Gd-EOB-DTPA+ (0.929 and 0.971) than in Gd-EOB-DTPA- (0.786 and 0.941) or gadobutrol (0.643 and 0.956). In 2 cases, tumor progression was detected by Gd-EOB-DTPA+ and by an increase in α-fetoprotein, but not by CT, gadobutrol, or Gd-EOB-DTPA-. Gd-EOB-DTPA+ MR imaging was not inferior to gadobutrol-enhanced MR imaging in therapy response evaluation after radioembolization and may allow a more accurate detection of early HCC recurrence in single cases. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.

  6. Long-Range Trends in the Development of Higher Education in Mining

    ERIC Educational Resources Information Center

    Pzhevskii, V. V.

    1978-01-01

    Reviews the relationship between scientific and technological progress, needs of the Soviet economy, and capacities of higher education institutions in terms of the future of the mining industry. Mining specialists will have to prepare for technical progress in the extracting industries, growth in production, complex mechanization, and automation…

  7. Progress Monitoring in Middle School Mathematics: Options and Issues

    ERIC Educational Resources Information Center

    Foegen, Anne

    2008-01-01

    This study investigated the technical features of six potential progress-monitoring measures in mathematics appropriate for use at the middle school level, including two commercially available measures for sixth-grade mathematics, two measures used in previous middle school studies, and two new measures of numeracy concepts. Five hundred…

  8. 10 CFR 600.341 - Monitoring and reporting program and financial performance.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... will be taken to address the deviations. (2) A final technical report if the award is for research and... dates for reports. At a minimum, requirements must include: (1) Periodic progress reports (at least... follows: (i) The program portions of the reports must address progress toward achieving program...

  9. 10 CFR 600.341 - Monitoring and reporting program and financial performance.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... will be taken to address the deviations. (2) A final technical report if the award is for research and... dates for reports. At a minimum, requirements must include: (1) Periodic progress reports (at least... follows: (i) The program portions of the reports must address progress toward achieving program...

  10. 10 CFR 600.341 - Monitoring and reporting program and financial performance.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... will be taken to address the deviations. (2) A final technical report if the award is for research and... dates for reports. At a minimum, requirements must include: (1) Periodic progress reports (at least... follows: (i) The program portions of the reports must address progress toward achieving program...

  11. 10 CFR 600.341 - Monitoring and reporting program and financial performance.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... will be taken to address the deviations. (2) A final technical report if the award is for research and... dates for reports. At a minimum, requirements must include: (1) Periodic progress reports (at least... follows: (i) The program portions of the reports must address progress toward achieving program...

  12. Nuclear waste management. Semiannual progress report, October 1982-March 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chikalla, T.D.; Powell, J.A.

    1983-06-01

    This document is one of a series of technical progress reports designed to report radioactive waste management programs at the Pacific Northwest Laboratory. Accomplishments in the following programs are reported: waste stabilization; Materials Characterization Center; waste isolation; low-level waste management; remedial action; and supporting studies.

  13. Advancing Stage 2 Research on Measures for Monitoring Kindergarten Reading Progress

    ERIC Educational Resources Information Center

    Clemens, Nathan H.; Soohoo, Michelle M.; Wiley, Colby P.; Hsiao, Yu-Yu; Estrella, Ivonne; Allee-Smith, Paula J.; Yoon, Myeongsun

    2018-01-01

    Although several measures exist for frequently monitoring early reading progress, little research has specifically investigated their technical properties when administered on a frequent basis with kindergarten students. In this study, kindergarten students (N = 137) of whom the majority was receiving supplemental intervention for reading skills…

  14. Membrane Signaling Induced by High Doses of Ionizing Radiation in the Endothelial Compartment. Relevance in Radiation Toxicity

    PubMed Central

    Corre, Isabelle; Guillonneau, Maëva; Paris, François

    2013-01-01

    Tumor areas can now be very precisely delimited thanks to technical progress in imaging and ballistics. This has also led to the development of novel radiotherapy protocols, delivering higher doses of ionizing radiation directly to cancer cells. Despite this, radiation toxicity in healthy tissue remains a major issue, particularly with dose-escalation in these new protocols. Acute and late tissue damage following irradiation have both been linked to the endothelium irrigating normal tissues. The molecular mechanisms involved in the endothelial response to high doses of radiation are associated with signaling from the plasma membrane, mainly via the acid sphingomyelinase/ceramide pathway. This review describes this signaling pathway and discusses the relevance of targeting endothelial signaling to protect healthy tissues from the deleterious effects of high doses of radiation. PMID:24252908

  15. Neurotrophin Signaling via Long-Distance Axonal Transport

    NASA Astrophysics Data System (ADS)

    Chowdary, Praveen D.; Che, Dung L.; Cui, Bianxiao

    2012-05-01

    Neurotrophins are a family of target-derived growth factors that support survival, development, and maintenance of innervating neurons. Owing to the unique architecture of neurons, neurotrophins that act locally on the axonal terminals must convey their signals across the entire axon for subsequent regulation of gene transcription in the cell nucleus. This long-distance retrograde signaling, a motor-driven process that can take hours or days, has been a subject of intense interest. In the last decade, live-cell imaging with high sensitivity has significantly increased our capability to track the transport of neurotrophins, their receptors, and subsequent signals in real time. This review summarizes recent research progress in understanding neurotrophin-receptor interactions at the axonal terminal and their transport dynamics along the axon. We emphasize high-resolution studies at the single-molecule level and also discuss recent technical advances in the field.

  16. Linking and integrating computers for maternity care.

    PubMed

    Lumb, M; Fawdry, R

    1990-12-01

    Functionally separate computer systems have been developed for many different areas relevant to maternity care, e.g. maternity data collection, pathology and imaging reports, staff rostering, personnel, accounting, audit, primary care etc. Using land lines, modems and network gateways, many such quite distinct computer programs or databases can be made accessible from a single terminal. If computer systems are to attain their full potential for the improvement of the maternity care, there will be a need not only for terminal emulation but also for more complex integration. Major obstacles must be overcome before such integration is widely achieved. Technical and conceptual progress towards overcoming these problems is discussed, with particular reference to the OSI (open systems interconnection) initiative, to the Read clinical classification and to the MUMMIES CBS (Common Basic Specification) Maternity Care Project. The issue of confidentiality is also briefly explored.

  17. The Navy Precision Optical Interferometer: an update

    NASA Astrophysics Data System (ADS)

    Armstrong, J. T.; Baines, Ellyn K.; Schmitt, Henrique R.; Restaino, Sergio R.; Clark, James H.; Benson, James A.; Hutter, Donald J.; Zavala, Robert T.; van Belle, Gerard T.

    2016-08-01

    We describe the current status of the Navy Precision Optical Interferometer (NPOI), including developments since the last SPIE meeting. The NPOI group has added stations as far as 250m from the array center and added numerous infrastructure improvements. Science programs include stellar diameters and limb darkening, binary orbits, Be star disks, exoplanet host stars, and progress toward high-resolution stellar surface imaging. Technical and infrastructure projects include on-sky demonstrations of baseline bootstrapping with six array elements and of the VISION beam combiner, control system updates, integration of the long delay lines, and updated firmware for the Classic beam combiner. Our plans to add up to four 1.8 m telescopes are no longer viable, but we have recently acquired separate funding for adding three 1 m AO-equipped telescopes and an infrared beam combiner to the array.

  18. [Artificial sight: recent developments].

    PubMed

    Zeitz, O; Keserü, M; Hornig, R; Richard, G

    2009-03-01

    The implantation of electronic retina stimulators appears to be a future possibility to restore vision, at least partially in patients with retinal degeneration. The idea of such visual prostheses is not new but due to the general technical progress it has become more likely that a functioning implant will be on the market soon. Visual prosthesis may be integrated in the visual system in various places. Thus there are subretinal and epiretinal implants, as well as implants that are connected directly to the optic nerve or the visual cortex. The epiretinal approach is the most promising at the moment, but the problem of appropriate modulation of the image information is unsolved so far. This will be necessary to provide a interpretable visual information to the brain. The present article summarises the concepts and includes some latest information from recent conferences.

  19. Technical guidance for the development of a solid state image sensor for human low vision image warping

    NASA Technical Reports Server (NTRS)

    Vanderspiegel, Jan

    1994-01-01

    This report surveys different technologies and approaches to realize sensors for image warping. The goal is to study the feasibility, technical aspects, and limitations of making an electronic camera with special geometries which implements certain transformations for image warping. This work was inspired by the research done by Dr. Juday at NASA Johnson Space Center on image warping. The study has looked into different solid-state technologies to fabricate image sensors. It is found that among the available technologies, CMOS is preferred over CCD technology. CMOS provides more flexibility to design different functions into the sensor, is more widely available, and is a lower cost solution. By using an architecture with row and column decoders one has the added flexibility of addressing the pixels at random, or read out only part of the image.

  20. High-Resolution X-Ray Telescopes

    NASA Technical Reports Server (NTRS)

    ODell, Stephen L.; Brissenden, Roger J.; Davis, William; Elsner, Ronald F.; Elvis, Martin; Freeman, Mark; Gaetz, Terry; Gorenstein, Paul; Gubarev, Mikhail V.

    2010-01-01

    Fundamental needs for future x-ray telescopes: a) Sharp images => excellent angular resolution. b) High throughput => large aperture areas. Generation-X optics technical challenges: a) High resolution => precision mirrors & alignment. b) Large apertures => lots of lightweight mirrors. Innovation needed for technical readiness: a) 4 top-level error terms contribute to image size. b) There are approaches to controlling those errors. Innovation needed for manufacturing readiness. Programmatic issues are comparably challenging.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This report summarizes geothermal technical assistance, R&D, and technology transfer activities of the Geo-Heat Center. It describes 95 contacts with parties during this period related to technical assistance with goethermal direct heat projects. Areas dealt with include geothermal heat pumps, space heating, greenhouses, aquaculture, equipment, economics, and resources. Research activities are summarized on geothermal district heating system cost evaluation and silica waste utilization project. Outreach activities include publication of a geothermal direct use Bulletin, dissemination of information, goethermal library, technical papers and seminars, and progress monitor reports on geothermal resources and utilization.

  2. Quantitative imaging biomarkers: a review of statistical methods for technical performance assessment.

    PubMed

    Raunig, David L; McShane, Lisa M; Pennello, Gene; Gatsonis, Constantine; Carson, Paul L; Voyvodic, James T; Wahl, Richard L; Kurland, Brenda F; Schwarz, Adam J; Gönen, Mithat; Zahlmann, Gudrun; Kondratovich, Marina V; O'Donnell, Kevin; Petrick, Nicholas; Cole, Patricia E; Garra, Brian; Sullivan, Daniel C

    2015-02-01

    Technological developments and greater rigor in the quantitative measurement of biological features in medical images have given rise to an increased interest in using quantitative imaging biomarkers to measure changes in these features. Critical to the performance of a quantitative imaging biomarker in preclinical or clinical settings are three primary metrology areas of interest: measurement linearity and bias, repeatability, and the ability to consistently reproduce equivalent results when conditions change, as would be expected in any clinical trial. Unfortunately, performance studies to date differ greatly in designs, analysis method, and metrics used to assess a quantitative imaging biomarker for clinical use. It is therefore difficult or not possible to integrate results from different studies or to use reported results to design studies. The Radiological Society of North America and the Quantitative Imaging Biomarker Alliance with technical, radiological, and statistical experts developed a set of technical performance analysis methods, metrics, and study designs that provide terminology, metrics, and methods consistent with widely accepted metrological standards. This document provides a consistent framework for the conduct and evaluation of quantitative imaging biomarker performance studies so that results from multiple studies can be compared, contrasted, or combined. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  3. Interventional articular and para-articular knee procedures

    PubMed Central

    Lalam, Radhesh K; Winn, Naomi

    2016-01-01

    The knee is a common area of the body to undergo interventional procedures. This article discusses image-guided interventional issues specific to the knee area. The soft tissues in and around the knee are frequently affected by sport-related injuries and often need image-guided intervention. This article details the specific technical issues related to intervention in these soft tissues, including the iliotibial tract, fat pads, patellar tendon and other tendons, bursae and the meniscus. Most often, simple procedures such as injection and aspiration are performed without image guidance. Rarely image-guided diagnostic arthrography and therapeutic joint injections are necessary. The technique, indications and diagnostic considerations for arthrography are discussed in this article. Primary bone and soft-tissue tumours may involve the knee and adjacent soft tissues. Image-guided biopsies are frequently necessary for these lesions; this article details the technical issues related to image-guided biopsy around the knee. A number of newer ablation treatments are now available, including cryoablation, high-frequency ultrasound and microwave ablation. Radiofrequency ablation, however, still remains the most commonly employed ablation technique. The indications, technical and therapeutic considerations related to the application of this technique around the knee are discussed here. Finally, we briefly discuss some newer, but as of yet, unproven image-guided interventions for osteochondral lesions and Brodie's abscess. PMID:26682669

  4. The evolution of endovascular electroencephalography: historical perspective and future applications.

    PubMed

    Sefcik, Roberta K; Opie, Nicholas L; John, Sam E; Kellner, Christopher P; Mocco, J; Oxley, Thomas J

    2016-05-01

    Current standard practice requires an invasive approach to the recording of electroencephalography (EEG) for epilepsy surgery, deep brain stimulation (DBS), and brain-machine interfaces (BMIs). The development of endovascular techniques offers a minimally invasive route to recording EEG from deep brain structures. This historical perspective aims to describe the technical progress in endovascular EEG by reviewing the first endovascular recordings made using a wire electrode, which was followed by the development of nanowire and catheter recordings and, finally, the most recent progress in stent-electrode recordings. The technical progress in device technology over time and the development of the ability to record chronic intravenous EEG from electrode arrays is described. Future applications for the use of endovascular EEG in the preoperative and operative management of epilepsy surgery are then discussed, followed by the possibility of the technique's future application in minimally invasive operative approaches to DBS and BMI.

  5. Direct imaging of explosives.

    PubMed

    Knapp, E A; Moler, R B; Saunders, A W; Trower, W P

    2000-01-01

    Any technique that can detect nitrogen concentrations can screen for concealed explosives. However, such a technique would have to be insensitive to metal, both encasing and incidental. If images of the nitrogen concentrations could be captured, then, since form follows function, a robust screening technology could be developed. However these images would have to be sensitive to the surface densities at or below that of the nitrogen contained in buried anti-personnel mines or of the SEMTEX that brought down Pan Am 103, approximately 200 g. Although the ability to image in three-dimensions would somewhat reduce false positives, capturing collateral images of carbon and oxygen would virtually assure that nitrogenous non-explosive material like fertilizer, Melmac dinnerware, and salami could be eliminated. We are developing such an instrument, the Nitrogen Camera, which has met experimentally these criteria with the exception of providing oxygen images, which awaits the availability of a sufficiently energetic light source. Our Nitrogen Camera technique uses an electron accelerator to produce photonuclear reactions whose unique decays it registers. Clearly if our Nitrogen Camera is made mobile, it could be effective in detecting buried mines, either in an active battlefield situation or in the clearing of abandoned military munitions. Combat operations require that a swathe the width of an armored vehicle, 5 miles deep, be screened in an hour, which is within our camera's scanning speed. Detecting abandoned munitions is technically easier as it is free from the onerous speed requirement. We describe here our Nitrogen Camera and show its 180 pixel intensity images of elemental nitrogen in a 200 g mine simulant and in a 125 g stick of SEMTEX. We also report on our progress in creating a lorry transportable 70 MeV electron racetrack microtron, the principal enabling technology that will allow our Nitrogen Camera to be deployed in the field.

  6. Technical success, technique efficacy and complications of minimally-invasive imaging-guided percutaneous ablation procedures of breast cancer: A systematic review and meta-analysis.

    PubMed

    Mauri, Giovanni; Sconfienza, Luca Maria; Pescatori, Lorenzo Carlo; Fedeli, Maria Paola; Alì, Marco; Di Leo, Giovanni; Sardanelli, Francesco

    2017-08-01

    To systematically review studies concerning imaging-guided minimally-invasive breast cancer treatments. An online database search was performed for English-language articles evaluating percutaneous breast cancer ablation. Pooled data and 95% confidence intervals (CIs) were calculated. Technical success, technique efficacy, minor and major complications were analysed, including ablation technique subgroup analysis and effect of tumour size on outcome. Forty-five studies were analysed, including 1,156 patients and 1,168 lesions. Radiofrequency (n=577; 50%), microwaves (n=78; 7%), laser (n=227; 19%), cryoablation (n=156; 13%) and high-intensity focused ultrasound (HIFU, n=129; 11%) were used. Pooled technical success was 96% (95%CI 94-97%) [laser=98% (95-99%); HIFU=96% (90-98%); radiofrequency=96% (93-97%); cryoablation=95% (90-98%); microwave=93% (81-98%)]. Pooled technique efficacy was 75% (67-81%) [radiofrequency=82% (74-88); cryoablation=75% (51-90); laser=59% (35-79); HIFU=49% (26-74)]. Major complications pooled rate was 6% (4-8). Minor complications pooled rate was 8% (5-13%). Differences between techniques were not significant for technical success (p=0.449), major complications (p=0.181) or minor complications (p=0.762), but significant for technique efficacy (p=0.009). Tumour size did not impact on variables (p>0.142). Imaging-guided percutaneous ablation techniques of breast cancer have a high rate of technical success, while technique efficacy remains suboptimal. Complication rates are relatively low. • Imaging-guided ablation techniques for breast cancer are 96% technically successful. • Overall technique efficacy rate is 75% but largely inhomogeneous among studies. • Overall major and minor complication rates are low (6-8%).

  7. THE DEVELOPMENT OF ACHIEVEMENT MEASURES FOR TRADE AND TECHNICAL EDUCATION. PROGRESS REPORT NUMBER THREE.

    ERIC Educational Resources Information Center

    BALDWIN, THOMAS S.

    DURING THIS PERIOD FROM SEPTEMBER 1 THROUGH NOVEMBER 30, 1966, 35 FIELD CONSULTANTS COMPLETED ANALYSIS OF THEIR INDIVIDUAL TRADE AND TECHNICAL CURRICULUMS. THESE ANALYSES WERE DEVELOPED INTO AN OUTLINE TO SERVE AS A GUIDE FOR DEVELOPING ACHIEVEMENT TESTS. THE FINAL OUTLINE WAS DIVIDED INTO AS MANY DIFFERENT AREAS AS THE CONSULTANTS FELT NECESSARY…

  8. 25 CFR 547.7 - What are the minimum technical hardware standards applicable to Class II gaming systems?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... OF CLASS II GAMES § 547.7 What are the minimum technical hardware standards applicable to Class II... the game, and are specially manufactured or proprietary and not off-the-shelf, shall display a unique... outcome or integrity of any game, progressive award, financial instrument, cashless transaction, voucher...

  9. 25 CFR 547.7 - What are the minimum technical hardware standards applicable to Class II gaming systems?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... OF CLASS II GAMES § 547.7 What are the minimum technical hardware standards applicable to Class II... the game, and are specially manufactured or proprietary and not off-the-shelf, shall display a unique... outcome or integrity of any game, progressive award, financial instrument, cashless transaction, voucher...

  10. 25 CFR 547.7 - What are the minimum technical hardware standards applicable to Class II gaming systems?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... OF CLASS II GAMES § 547.7 What are the minimum technical hardware standards applicable to Class II... the game, and are specially manufactured or proprietary and not off-the-shelf, shall display a unique... outcome or integrity of any game, progressive award, financial instrument, cashless transaction, voucher...

  11. Diagnostic Efficiency of easyCBM[R] Math: Washington State. Technical Report #1008

    ERIC Educational Resources Information Center

    Anderson, Daniel; Alonzo, Julie; Tindal, Gerald

    2010-01-01

    easyCBM[R] is an online benchmark and progress monitoring assessment system designed for use within a response to intervention framework. Educators using easyCBM[R] are often interested in using the results to predict students' state test performance. In the following technical document, we report diagnostic efficiency statistics using a sample…

  12. U.S. TIMSS and PIRLS 2011 Technical Report and User's Guide. NCES 2013-046

    ERIC Educational Resources Information Center

    Kastberg, David; Roey, Stephen; Ferraro, David; Lemanski, Nita; Erberber, Ebru

    2013-01-01

    The "U.S. TIMSS and PIRLS 2011 Technical Report and User's Guide" provides an overview of the design and implementation of the Trends in International Mathematics and Science Study (TIMSS) 2011 and the Progress in International Reading Literacy Study (PIRLS) 2011 in the United States and the nine participating benchmarking states:…

  13. Longitudinal Surveys of Australian Youth (LSAY) 1998 Cohort: Wave 12 (2009)--Questionnaire. Technical Report 58A

    ERIC Educational Resources Information Center

    National Centre for Vocational Education Research (NCVER), 2010

    2010-01-01

    The Longitudinal Surveys of Australian Youth (LSAY) program studies the progress of several groups of young Australians as they move from school into post-secondary education and work. This technical paper contains the questionnaire for the LSAY 1998 cohort Wave 12 (2009) data set. [For the accompanying frequency tables, "Longitudinal Surveys…

  14. The Development of the easyCBM CCSS Reading Assessments: Grade 3. Technical Report #1221

    ERIC Educational Resources Information Center

    Alonzo, Julie; Park, Bitnara Jasmine; Tindal, Gerald

    2012-01-01

    In this technical report, we document the development and piloting of easyCBM reading measures aligned to the Common Core State Standards, designed for use in screening students at risk for reading difficulty and monitoring their progress as they develop reading skills. The measures, which assess students' ability to respond to…

  15. Developing Technical Writing Skills in the Physical Chemistry Laboratory: A Progressive Approach Employing Peer Review

    ERIC Educational Resources Information Center

    Gragson, Derek E.; Hagen, John P.

    2010-01-01

    Writing formal "journal-style" lab reports is often one of the requirements chemistry and biochemistry students encounter in the physical chemistry laboratory. Helping students improve their technical writing skills is the primary reason this type of writing is a requirement in the physical chemistry laboratory. Developing these skills is an…

  16. Quality and Quality Assurance in Technical and Vocational Education and Training. Thematic Studies

    ERIC Educational Resources Information Center

    Seyfried, Erwin

    2008-01-01

    In many countries in both the Mediterranean region and the European Union (EU), interest in the quality of, and improvements to, technical and vocational education and training (TVET) systems has increased progressively in recent years. The main reason underlying this interest is a growing awareness of the key role played by education and training…

  17. The Development of CBM Vocabulary Measures: Grade 4. Technical Report #1211

    ERIC Educational Resources Information Center

    Alonzo, Julie; Anderson, Daniel; Park, Bitnara Jasmine; Tindal, Gerald

    2012-01-01

    In this technical report, we describe the development and piloting of a series of vocabulary assessments intended for use with students in grades two through eight. These measures, available as part of easyCBM[TM], an online progress monitoring and benchmark/screening assessment system, were developed in 2010 and administered to approximately 1200…

  18. The Development of CBM Vocabulary Measures: Grade 7. Technical Report #1214

    ERIC Educational Resources Information Center

    Alonzo, Julie; Anderson, Daniel; Park, Bitnara Jasmine; Tindal, Gerald

    2012-01-01

    In this technical report, we describe the development and piloting of a series of vocabulary assessments intended for use with students in grades two through eight. These measures, available as part of easyCBM[TM], an online progress monitoring and benchmark/screening assessment system, were developed in 2010 and administered to approximately 1200…

  19. The Development of CBM Vocabulary Measures: Grade 5. Technical Report #1212

    ERIC Educational Resources Information Center

    Alonzo, Julie; Anderson, Daniel; Park, Bitnara Jasmine; Tindal, Gerald

    2012-01-01

    In this technical report, we describe the development and piloting of a series of vocabulary assessments intended for use with students in grades two through eight. These measures, available as part of easyCBM[TM], an online progress monitoring and benchmark/screening assessment system, were developed in 2010 and administered to approximately 1200…

  20. The Development of CBM Vocabulary Measures: Grade 8. Technical Report #1215

    ERIC Educational Resources Information Center

    Alonzo, Julie; Anderson, Daniel; Park, Bitnara Jasmine; Tindal, Gerald

    2012-01-01

    In this technical report, we describe the development and piloting of a series of vocabulary assessments intended for use with students in grades two through eight. These measures, available as part of easyCBM[TM], an online progress monitoring and benchmark/screening assessment system, were developed in 2010 and administered to approximately 1200…

  1. The Development of CBM Vocabulary Measures: Grade 2. Technical Report #1209

    ERIC Educational Resources Information Center

    Alonzo, Julie; Anderson, Daniel; Park, Bitnara Jasmine; Tindal, Gerald

    2012-01-01

    In this technical report, we describe the development and piloting of a series of vocabulary assessments intended for use with students in grades two through eight. These measures, available as part of easyCBM[TM], an online progress monitoring and benchmark/screening assessment system, were developed in 2010 and administered to approximately 1200…

  2. The Development of CBM Vocabulary Measures: Grade 3. Technical Report #1210

    ERIC Educational Resources Information Center

    Alonzo, Julie; Anderson, Daniel; Park, Bitnara Jasmine; Tindal, Gerald

    2012-01-01

    In this technical report, we describe the development and piloting of a series of vocabulary assessments intended for use with students in grades two through eight. These measures, available as part of easyCBM[TM], an online progress monitoring and benchmark/screening assessment system, were developed in 2010 and administered to approximately 1200…

  3. The Development of CBM Vocabulary Measures: Grade 6. Technical Report # 1213

    ERIC Educational Resources Information Center

    Alonzo, Julie; Anderson, Daniel; Park, Bitnara Jasmine; Tindal, Gerald

    2012-01-01

    In this technical report, we describe the development and piloting of a series of vocabulary assessments intended for use with students in grades two through eight. These measures, available as part of easyCBM[TM], an online progress monitoring and benchmark/screening assessment system, were developed in 2010 and administered to approximately 1200…

  4. Application of Communications Satellites to Educational Development. Final Technical Report, September 1, 1969-August 31, 1975.

    ERIC Educational Resources Information Center

    Morgan, Robert P.

    Research is summarized in a brief final report built around a four-section bibliography. The first section lists periodic progress reports and articles which provide an overview of the program, including articles which pertain primarily to educational rather than technical aspects of satellite utilization. Theses carried out in the fields of…

  5. Review of dynamic contrast-enhanced MRI: Technical aspects and applications in the musculoskeletal system.

    PubMed

    Sujlana, Parvinder; Skrok, Jan; Fayad, Laura M

    2018-04-01

    Although postcontrast imaging has been used for many years in musculoskeletal imaging, dynamic contrast enhanced (DCE) MRI is not routinely used in many centers around the world. Unlike conventional contrast-enhanced sequences, DCE-MRI allows the evaluation of the temporal pattern of enhancement in the musculoskeletal system, perhaps best known for its use in oncologic applications (such as differentiating benign from malignant tumors, evaluating for treatment response after neoadjuvant chemotherapy, and differentiating postsurgical changes from residual tumor). However, DCE-MRI can also be used to evaluate inflammatory processes such as Charcot foot and synovitis, and evaluate bone perfusion in entities like Legg Calve Perthes disease and arthritis. Finally, vascular abnormalities and associated complications may be better characterized with DCE-MRI than conventional imaging. The goal of this article is to review the applications and technical aspects of DCE-MRI in the musculoskeletal system. 5 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;47:875-890. © 2017 International Society for Magnetic Resonance in Medicine.

  6. Technical efficiency and productivity of Chinese county hospitals: an exploratory study in Henan province, China.

    PubMed

    Cheng, Zhaohui; Tao, Hongbing; Cai, Miao; Lin, Haifeng; Lin, Xiaojun; Shu, Qin; Zhang, Ru-Ning

    2015-09-09

    Chinese county hospitals have been excessively enlarging their scale during the healthcare reform since 2009. The purpose of this paper is to examine the technical efficiency and productivity of county hospitals during the reform process, and to determine whether, and how, efficiency is affected by various factors. 114 sample county hospitals were selected from Henan province, China, from 2010 to 2012. Data envelopment analysis was employed to estimate the technical and scale efficiency of sample hospitals. The Malmquist index was used to calculate productivity changes over time. Tobit regression was used to regress against 4 environmental factors and 5 institutional factors that affected the technical efficiency. (1) 112 (98.2%), 112 (98.2%) and 104 (91.2%) of the 114 sample hospitals ran inefficiently in 2010, 2011 and 2012, with average technical efficiency of 0.697, 0.748 and 0.790, respectively. (2) On average, during 2010-2012, productivity of sample county hospitals increased by 7.8%, which was produced by the progress in technical efficiency changes and technological changes of 0.9% and 6.8%, respectively. (3) Tobit regression analysis indicated that government subsidy, hospital size with above 618 beds and average length of stay assumed a negative sign with technical efficiency; bed occupancy rate, ratio of beds to nurses and ratio of nurses to physicians assumed a positive sign with technical efficiency. There was considerable space for technical efficiency improvement in Henan county hospitals. During 2010-2012, sample hospitals experienced productivity progress; however, the adverse change in pure technical efficiency should be emphasised. Moreover, according to the Tobit results, policy interventions that strictly supervise hospital bed scale, shorten the average length of stay and coordinate the proportion among physicians, nurses and beds, would benefit hospital efficiency. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  7. Technical efficiency and productivity of Chinese county hospitals: an exploratory study in Henan province, China

    PubMed Central

    Cheng, Zhaohui; Tao, Hongbing; Cai, Miao; Lin, Haifeng; Lin, Xiaojun; Shu, Qin; Zhang, Ru-ning

    2015-01-01

    Objectives Chinese county hospitals have been excessively enlarging their scale during the healthcare reform since 2009. The purpose of this paper is to examine the technical efficiency and productivity of county hospitals during the reform process, and to determine whether, and how, efficiency is affected by various factors. Setting and participants 114 sample county hospitals were selected from Henan province, China, from 2010 to 2012. Outcome measures Data envelopment analysis was employed to estimate the technical and scale efficiency of sample hospitals. The Malmquist index was used to calculate productivity changes over time. Tobit regression was used to regress against 4 environmental factors and 5 institutional factors that affected the technical efficiency. Results (1) 112 (98.2%), 112 (98.2%) and 104 (91.2%) of the 114 sample hospitals ran inefficiently in 2010, 2011 and 2012, with average technical efficiency of 0.697, 0.748 and 0.790, respectively. (2) On average, during 2010–2012, productivity of sample county hospitals increased by 7.8%, which was produced by the progress in technical efficiency changes and technological changes of 0.9% and 6.8%, respectively. (3) Tobit regression analysis indicated that government subsidy, hospital size with above 618 beds and average length of stay assumed a negative sign with technical efficiency; bed occupancy rate, ratio of beds to nurses and ratio of nurses to physicians assumed a positive sign with technical efficiency. Conclusions There was considerable space for technical efficiency improvement in Henan county hospitals. During 2010–2012, sample hospitals experienced productivity progress; however, the adverse change in pure technical efficiency should be emphasised. Moreover, according to the Tobit results, policy interventions that strictly supervise hospital bed scale, shorten the average length of stay and coordinate the proportion among physicians, nurses and beds, would benefit hospital efficiency. PMID:26353864

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gauglitz, Phillip A.; Bontha, Jagannadha R.; Daniel, Richard C.

    The Hanford Waste Treatment and Immobilization Plant (WTP) is currently being designed and constructed to pretreat and vitrify a large portion of the waste in the 177 underground waste storage tanks at the Hanford Site. A number of technical issues related to the design of the pretreatment facility (PTF) of the WTP have been identified. These issues must be resolved prior to the U.S. Department of Energy (DOE) Office of River Protection (ORP) reaching a decision to proceed with engineering, procurement, and construction activities for the PTF. One of the issues is Technical Issue T1 - Hydrogen Gas Release frommore » Vessels (hereafter referred to as T1). The focus of T1 is identifying controls for hydrogen release and completing any testing required to close the technical issue. In advance of selecting specific controls for hydrogen gas safety, a number of preliminary technical studies were initiated to support anticipated future testing and to improve the understanding of hydrogen gas generation, retention, and release within PTF vessels. These activities supported the development of a plan defining an overall strategy and approach for addressing T1 and achieving technical endpoints identified for T1. Preliminary studies also supported the development of a test plan for conducting testing and analysis to support closing T1. Both of these plans were developed in advance of selecting specific controls, and in the course of working on T1 it was decided that the testing and analysis identified in the test plan were not immediately needed. However, planning activities and preliminary studies led to significant technical progress in a number of areas. This report summarizes the progress to date from the preliminary technical studies. The technical results in this report should not be used for WTP design or safety and hazards analyses and technical results are marked with the following statement: “Preliminary Technical Results for Planning – Not to be used for WTP Design or Safety Analyses.”« less

  9. Various MRS application tools for Alzheimer disease and mild cognitive impairment.

    PubMed

    Gao, F; Barker, P B

    2014-06-01

    MR spectroscopy is a noninvasive technique that allows the detection of several naturally occurring compounds (metabolites) from well-defined regions of interest within the human brain. Alzheimer disease, a progressive neurodegenerative disorder, is the most common cause of dementia in the elderly. During the past 20 years, multiple studies have been performed on MR spectroscopy in patients with both mild cognitive impairment and Alzheimer disease. Generally, MR spectroscopy studies have found decreased N-acetylaspartate and increased myo-inositol in both patients with mild cognitive impairment and Alzheimer disease, with greater changes in Alzheimer disease than in mild cognitive impairment. This review summarizes the information content of proton brain MR spectroscopy and its related technical aspects, as well as applications of MR spectroscopy to mild cognitive impairment and Alzheimer disease. While MR spectroscopy may have some value in the differential diagnosis of dementias and assessing prognosis, more likely its role in the near future will be predominantly as a tool for monitoring disease response or progression in treatment trials. More work is needed to evaluate the role of MR spectroscopy as a biomarker in Alzheimer disease and its relationship to other imaging modalities. © 2014 by American Journal of Neuroradiology.

  10. Fetal transesophageal echocardiography: clinical introduction as a monitoring tool during cardiac intervention in a human fetus.

    PubMed

    Kohl, T; Müller, A; Tchatcheva, K; Achenbach, S; Gembruch, U

    2005-12-01

    Because of insufficient imaging by maternal transabdominal fetal echocardiography (TAE) in a human fetus with aortic atresia, imperforate atrial septum and progressive cardiac failure, we assessed the feasibility of fetal transesophageal echocardiography (TEE) as a monitoring tool during fetal cardiac intervention at 24 + 6 weeks of gestation. Percutaneous fetoscopic intraesophageal deployment of the ultrasound catheter was achieved and did not result in any maternal or fetal complications. Fetal TEE permitted substantially clearer definition of fetal cardiac anatomy and intracardiac device manipulations than conventional maternal TAE. Despite the employment of various devices, no sufficiently large opening could be achieved within the atrial septum. Although the fetus tolerated the procedure remarkably well and satisfactory fetoplacental flow could be documented at the end of the procedure, the fetus died from progressive cardiac failure 3 days after the intervention. Fetoscopic TEE is feasible in the human fetus and permits substantially clearer definition of fetal cardiac anatomy and intracardiac manipulations than conventional maternal TAE. Based on the observation of spontaneous closure of multiple iatrogenic perforations of the atrial septum, specialized devices are required in order to improve the technical success rate of septoplasty methods and hence the survival odds of these high-risk patients.

  11. Cancer nanotechnology research in the United States and China: cooperation to promote innovation.

    PubMed

    Schneider, Julie A; Grodzinski, Piotr; Liang, Xing-Jie

    2011-01-01

    The application of nanotechnology to cancer research is a promising area for US-China cooperation. Cancer is a major public health burden in both countries, and progress in cancer nanotechnology research is increasing in several fields, including imaging, biomarker detection, and targeted drug delivery. The United States and China are international leaders in nanotechnology research, and have both launched national programs to support nanotechnology efforts in the recent past. The accelerating trend of co-authorship among US and Chinese nanotechnology researchers demonstrates that individual scientists already recognize the potential for cooperation, providing a strong platform for creating additional partnerships in pre-competitive research areas. Mechanisms that could help to enhance US-China cancer nanotechnology partnerships include: developing new programs for bi-directional training and exchange; convening workshops focused on specific scientific topics of high priority to both countries; and joint support of collaborative research projects by US and Chinese funders. In addition to the accelerating scientific progress, expanded cooperation will stimulate important dialog on regulatory, policy, and technical issues needed to lay the groundwork for US and Chinese scientists to move greater numbers of cancer nanotechnology applications into the clinic. Copyright © 2011 John Wiley & Sons, Inc.

  12. Adaptive optics for in-vivo exploration of human retinal structures

    NASA Astrophysics Data System (ADS)

    Paques, Michel; Meimon, Serge; Grieve, Kate; Rossant, Florence

    2017-06-01

    Adaptive optics (AO)-enhanced imaging of the retina is now reaching a level of technical maturity which fosters its expanding use in research and clinical centers in the world. By achieving wavelength-limited resolution it did not only allow a better observation of retinal substructures already visible by other means, it also broke anatomical frontiers such as individual photoreceptors or vessel walls. The clinical applications of AO-enhanced imaging has been slower than that of optical coherence tomography because of the combination of technical complexity, costs and the paucity of interpretative scheme of complex data. In several diseases, AO-enhanced imaging has already proven to provide added clinical value and quantitative biomarkers. Here, we will review some of the clinical applications of AO-enhanced en face imaging, and trace perspectives to improve its clinical pertinence in these applications. An interesting perspective is to document cell motion through time-lapse imaging such as during agerelated macular degeneration. In arterial hypertension, the possibility to measure parietal thickness and perform fine morphometric analysis is of interest for monitoring patients. In the near future, implementation of novel approaches and multimodal imaging, including in particular optical coherence tomography, will undoubtedly expand our imaging capabilities. Tackling the technical, scientific and medical challenges offered by high resolution imaging are likely to contribute to our rethinking of many retinal diseases, and, most importantly, may find applications in other areas of medicine.

  13. A methodology to event reconstruction from trace images.

    PubMed

    Milliet, Quentin; Delémont, Olivier; Sapin, Eric; Margot, Pierre

    2015-03-01

    The widespread use of digital imaging devices for surveillance (CCTV) and entertainment (e.g., mobile phones, compact cameras) has increased the number of images recorded and opportunities to consider the images as traces or documentation of criminal activity. The forensic science literature focuses almost exclusively on technical issues and evidence assessment [1]. Earlier steps in the investigation phase have been neglected and must be considered. This article is the first comprehensive description of a methodology to event reconstruction using images. This formal methodology was conceptualised from practical experiences and applied to different contexts and case studies to test and refine it. Based on this practical analysis, we propose a systematic approach that includes a preliminary analysis followed by four main steps. These steps form a sequence for which the results from each step rely on the previous step. However, the methodology is not linear, but it is a cyclic, iterative progression for obtaining knowledge about an event. The preliminary analysis is a pre-evaluation phase, wherein potential relevance of images is assessed. In the first step, images are detected and collected as pertinent trace material; the second step involves organising and assessing their quality and informative potential. The third step includes reconstruction using clues about space, time and actions. Finally, in the fourth step, the images are evaluated and selected as evidence. These steps are described and illustrated using practical examples. The paper outlines how images elicit information about persons, objects, space, time and actions throughout the investigation process to reconstruct an event step by step. We emphasise the hypothetico-deductive reasoning framework, which demonstrates the contribution of images to generating, refining or eliminating propositions or hypotheses. This methodology provides a sound basis for extending image use as evidence and, more generally, as clues in investigation and crime reconstruction processes. Copyright © 2015 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  14. Home | Oregon State University Extension Service

    Science.gov Websites

    "How To" Communities OSU Open Campus Oregon's Agricultural Progress Magazine Emerging Issues Oregon's Agricultural Progress cover image Oregon's Agricultural Progress, the research magazine for the Oregon State University Agricultural Experiment Station. Read current OAP issue » Bridges logo image

  15. Scientific and Technical Information. Handbook for Technical Report Preparation

    DTIC Science & Technology

    1991-05-31

    31................. 16 Typography .......................................... 32.... ... ........ 16 Section Vill--REQUIREMENTS...marks. 16 AFDTCP 83-2 31 May 1991 SECTION VII ERRATA/ TYPOGRAPHY 31. ERRATA. Errors are normally corrected during proofing. If an error does-become... TYPOGRAPHY : a. Paper Size and Image Area. Paper size will be 8 1/2 by irc.• .,,.;od quality 50-pound white bond stock. The image area should be 6 1/2- by 8 3/4

  16. Technical assessment of a cone-beam CT scanner for otolaryngology imaging: image quality, dose, and technique protocols.

    PubMed

    Xu, J; Reh, D D; Carey, J P; Mahesh, M; Siewerdsen, J H

    2012-08-01

    As cone-beam CT (CBCT) systems dedicated to various imaging specialties proliferate, technical assessment grounded in imaging physics is important to ensuring that image quality and radiation dose are quantified, understood, and justified. This paper involves technical assessment of a new CBCT scanner (CS 9300, Carestream Health, Rochester, NY) dedicated to imaging of the ear and sinuses for applications in otolaryngology-head and neck surgery (OHNS). The results guided evaluation of technique protocols to minimize radiation dose in a manner sufficient for OHNS imaging tasks. The technical assessment focused on the imaging performance and radiation dose for each of seven technique protocols recommended by the manufacturer: three sinus protocols and four ear (temporal bone) protocols. Absolute dose was measured using techniques adapted from AAPM Task Group Report No. 111, involving three stacked 16 cm diameter acrylic cylinders (CTDI phantoms) and a 0.6 cm(3) Farmer ionization chamber to measure central and peripheral dose. The central dose (D(o)) was also measured as a function of longitudinal position (z) within and beyond the primary radiation field to assess, for example, out-of-field dose to the neck. Signal-difference-to-noise ratio (SDNR) and Hounsfield unit (HU) accuracy were assessed in a commercially available quality assurance phantom (CATPHAN module CTP404, The Phantom Laboratory, Greenwich, NY) and a custom phantom with soft-tissue-simulating plastic inserts (Gammex RMI, Madison, WI). Spatial resolution was assessed both qualitatively (a line-pair pattern, CATPHAN module CTP528) and quantitatively (modulation transfer function, MTF, measured with a wire phantom). Imaging performance pertinent to various OHNS imaging tasks was qualitatively assessed using an anthropomorphic phantom as evaluated by two experienced OHNS specialists. The technical assessment motivated a variety of modifications to the manufacturer-specified protocols to provide reduced radiation dose without compromising pertinent task-based imaging performance. The revised protocols yielded D(o) ranging 2.9-5.7 mGy, representing a ∼30% reduction in dose from the original technique chart. Out-of-field dose was ∼10% of D(o) at a distance of ∼8 cm from the field edge. Soft-tissue contrast resolution was fairly limited (water-brain SDNR ∼0.4-0.7) while high-contrast performance was reasonably good (SDNR ∼2-4 for a polystyrene insert in the CATPHAN). The scanner does not demonstrate (or claim to provide) accurate HU and exhibits a systematic error in CT number that could potentially be addressed by further calibration. The spatial resolution is ∼10-16 lp∕cm as assessed in a line-pair phantom, with MTF exceeding 10% out to ∼20 lp∕cm. Qualitative assessment by expert readers suggested limited soft-tissue visibility but excellent high-contrast (bone) visualization with isotropic spatial resolution suitable to a broad spectrum of pertinent sinus and temporal bone imaging tasks. The CBCT scanner provided spatial and contrast resolution suitable to visualization of high-contrast morphology in sinus, maxillofacial, and otologic imaging applications. Rigorous technical assessment guided revision of technique protocols to reduce radiation dose while maintaining image quality sufficient for pertinent imaging tasks. The scanner appears well suited to high-contrast sinus and temporal bone imaging at doses comparable to or less than that reported for conventional diagnostic CT of the head.

  17. Automotive Stirling engine development program

    NASA Technical Reports Server (NTRS)

    Ernst, W.; Richey, A.; Farrell, R.; Riecke, G.; Smith, G.; Howarth, R.; Cronin, M.; Simetkosky, M.; Meacher, J.

    1986-01-01

    This is the ninth Semiannual Technical Progress Report prepared under the Automotive Stirling Engine Development Program. It covers the twenty-eighth and twenty-ninth quarters of activity after award of the contract. Quarterly Technical Progress Reports related program activities from the first through the thirteenth quarters; thereafter, reporting was changed to a Semiannual format. This report summarizes the study of higher-power kinematic Stirling engines for transportation use, development testing of Mod I Stirling engines, and component development activities. Component development testing included successful conical fuel nozzle testing and functional checkout of Mod II controls and auxiliaries on Mod I engine test beds. Overall program philosophy is outlined and data and test results are presented.

  18. Publications of the Jet Propulsion Laboratory, 1981

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Over 500 externally distributed technical reports released during 1981 that resulted from scientific and engineering work performed, or managed by Jet Propulsion Laboratory are listed by primary author. Of the total number of entries, 311 are from the bimonthly Deep Space Network Progress Report, and its successor, the Telecommunications and Data Acquisition Progress Report.

  19. 40 CFR 35.4170 - What kinds of reporting does EPA require?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... OTHER FEDERAL ASSISTANCE STATE AND LOCAL ASSISTANCE Grants for Technical Assistance Managing Your Tag... period which ends June 30 and December 31 of each year. (b) [Reserved] (c) Progress Report Full description in chart or narrative format of the progress your group made in relation to your approved schedule...

  20. 77 FR 75441 - Healthy Home and Lead Hazard Control Grant Programs Data Collection; Progress Reporting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-20

    ... DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT [Docket No. FR-5603-N-93] Healthy Home and Lead Hazard... collection is designed to provide HUD timely information on progress of Healthy Homes Demonstration Program, Healthy Homes Technical Studies Program, Lead Base paint Hazard Control program, Lead Hazard Reduction...

  1. Measuring Student Progress in the Classroom: A Guide to Testing and Evaluating Progress of Students with Disabilities.

    ERIC Educational Resources Information Center

    Hartman, Rhona C.; Redden, Martha Ross

    This fact sheet provides guidelines on adapting testing situations for disabled postsecondary students. Discussed in the first section are considerations in determining when testing adaptations are needed including disability verification procedures, policy consistency, and maintenance of academic and technical standards. Facts about disabilities…

  2. Progress in the First Five Years: An Evaluation of Achieving the Dream Colleges in Washington State

    ERIC Educational Resources Information Center

    Jenkins, Davis; Wachen, John; Kerrigan, Monica Reid; Mayer, Alexander K.

    2012-01-01

    In 2006, six community and technical colleges in Washington State joined the innovative national reform initiative called Achieving the Dream (ATD). This report describes the progress each college made in implementing ATD's "culture of evidence" principles for institutional improvement, examines strategies implemented by the colleges to…

  3. Technical Considerations on Scanning and Image Analysis for Amyloid PET in Dementia.

    PubMed

    Akamatsu, Go; Ohnishi, Akihito; Aita, Kazuki; Ikari, Yasuhiko; Yamamoto, Yasuji; Senda, Michio

    2017-01-01

    Brain imaging techniques, such as computed tomography (CT), magnetic resonance imaging (MRI), single photon emission computed tomography (SPECT), and positron emission tomography (PET), can provide essential and objective information for the early and differential diagnosis of dementia. Amyloid PET is especially useful to evaluate the amyloid-β pathological process as a biomarker of Alzheimer's disease. This article reviews critical points about technical considerations on the scanning and image analysis methods for amyloid PET. Each amyloid PET agent has its own proper administration instructions and recommended uptake time, scan duration, and the method of image display and interpretation. In addition, we have introduced general scanning information, including subject positioning, reconstruction parameters, and quantitative and statistical image analysis. We believe that this article could make amyloid PET a more reliable tool in clinical study and practice.

  4. Hybrid PET/MR imaging: physics and technical considerations.

    PubMed

    Shah, Shetal N; Huang, Steve S

    2015-08-01

    In just over a decade, hybrid imaging with FDG PET/CT has become a standard bearer in the management of cancer patients. An exquisitely sensitive whole-body imaging modality, it combines the ability to detect subtle biologic changes with FDG PET and the anatomic information offered by CT scans. With advances in MR technology and advent of novel targeted PET radiotracers, hybrid PET/MRI is an evolutionary technique that is poised to revolutionize hybrid imaging. It offers unparalleled spatial resolution and functional multi-parametric data combined with biologic information in the non-invasive detection and characterization of diseases, without the deleterious effects of ionizing radiation. This article reviews the basic principles of FDG PET and MR imaging, discusses the salient technical developments of hybrid PET/MR systems, and provides an introduction to FDG PET/MR image acquisition.

  5. [Research Progress of Multi-Model Medical Image Fusion at Feature Level].

    PubMed

    Zhang, Junjie; Zhou, Tao; Lu, Huiling; Wang, Huiqun

    2016-04-01

    Medical image fusion realizes advantage integration of functional images and anatomical images.This article discusses the research progress of multi-model medical image fusion at feature level.We firstly describe the principle of medical image fusion at feature level.Then we analyze and summarize fuzzy sets,rough sets,D-S evidence theory,artificial neural network,principal component analysis and other fusion methods’ applications in medical image fusion and get summery.Lastly,we in this article indicate present problems and the research direction of multi-model medical images in the future.

  6. A Tool for Measuring NASA's Aeronautics Research Progress Toward Planned Strategic Community Outcomes

    NASA Technical Reports Server (NTRS)

    Tahmasebi, Farhad; Pearce, Robert

    2016-01-01

    Description of a tool for portfolio analysis of NASA's Aeronautics research progress toward planned community strategic Outcomes is presented. For efficiency and speed, the tool takes advantage of a function developed in Excels Visual Basic for Applications. The strategic planning process for determining the community Outcomes is also briefly discussed. Stakeholder buy-in, partnership performance, progress of supporting Technical Challenges, and enablement forecast are used as the criteria for evaluating progress toward Outcomes. A few illustrative examples of using the tool are also presented.

  7. Intravital imaging reveals new ancillary mechanisms co-opted by cancer cells to drive tumor progression

    PubMed Central

    Lucas, Morghan C.; Timpson, Paul

    2016-01-01

    Intravital imaging is providing new insights into the dynamics of tumor progression in native tissues and has started to reveal the layers of complexity found in cancer. Recent advances in intravital imaging have allowed us to look deeper into cancer behavior and to dissect the interactions between tumor cells and the ancillary host niche that promote cancer development. In this review, we provide an insight into the latest advances in cancer biology achieved by intravital imaging, focusing on recently discovered mechanisms by which tumor cells manipulate normal tissue to facilitate disease progression. PMID:27239290

  8. Imaging Virus-Associated Cancer

    PubMed Central

    Fu, De-Xue; Foss, Catherine A.; Nimmagadda, Sridhar; Ambinder, Richard F.; Pomper, Martin G.

    2012-01-01

    Cancer remains an important and growing health problem. Researchers have made great progress in defining genetic and molecular alterations that contribute to cancer formation and progression. Molecular imaging can identify appropriate patients for targeted cancer therapy and may detect early biochemical changes in tumors during therapy, some of which may have important prognostic implications. Progress in this field continues largely due to a union between molecular genetics and advanced imaging technology. This review details uses of molecular-genetic imaging in the context of tumor-associated viruses. Under certain conditions, and particularly during pharmacologic stimulation, gammaherpesviruses will express genes that enable imaging and therapy in vivo. The techniques discussed are readily translatable to the clinic. PMID:18991718

  9. Imaging outcome measures for progressive multiple sclerosis trials

    PubMed Central

    Moccia, Marcello; de Stefano, Nicola; Barkhof, Frederik

    2017-01-01

    Imaging markers that are reliable, reproducible and sensitive to neurodegenerative changes in progressive multiple sclerosis (MS) can enhance the development of new medications with a neuroprotective mode-of-action. Accordingly, in recent years, a considerable number of imaging biomarkers have been included in phase 2 and 3 clinical trials in primary and secondary progressive MS. Brain lesion count and volume are markers of inflammation and demyelination and are important outcomes even in progressive MS trials. Brain and, more recently, spinal cord atrophy are gaining relevance, considering their strong association with disability accrual; ongoing improvements in analysis methods will enhance their applicability in clinical trials, especially for cord atrophy. Advanced magnetic resonance imaging (MRI) techniques (e.g. magnetization transfer ratio (MTR), diffusion tensor imaging (DTI), spectroscopy) have been included in few trials so far and hold promise for the future, as they can reflect specific pathological changes targeted by neuroprotective treatments. Position emission tomography (PET) and optical coherence tomography have yet to be included. Applications, limitations and future perspectives of these techniques in clinical trials in progressive MS are discussed, with emphasis on measurement sensitivity, reliability and sample size calculation. PMID:29041865

  10. Career and Technical Education and Academic Progress at the End of High School: Evidence from the Education Longitudinal Study of 2002

    ERIC Educational Resources Information Center

    Bozick, Robert; Dalton, Ben

    2013-01-01

    This report examines the role of career and technical education (CTE) for assessing students in learning mathematics and preventing students from dropping out of high school. CTE is a wide field of educational practice that includes occupational training and career preparation offered in formats ranging from individual courses to comprehensive…

  11. easyCBM[R] Mathematics Criterion Related Validity Evidence: Oregon State Test. Technical Report #1011

    ERIC Educational Resources Information Center

    Anderson, Daniel; Alonzo, Julie; Tindal, Gerald

    2010-01-01

    In this technical report, we present the results of a study examining the relation between the math measures available on the easyCBM[R] online benchmark and progress monitoring assessment system and the Oregon statewide assessment of mathematics. Designed for use within a response to intervention (RTI) framework, easyCBM[R] is intended to help…

  12. New York City School Survey 2008-2010: Assessing the Reliability and Validity of a Progress Report Measure. Technical Appendices

    ERIC Educational Resources Information Center

    Nathanson, Lori; Cole, Rachel; Kemple, James J.; Lent, Jessica; McCormick, Meghan; Segeritz, Micha

    2013-01-01

    The Research Alliance for New York City Schools examined Department of Education (DOE) School Survey data from 2008-2010 to better understand the richness and complexities of the information elicited by the Survey from parents, students, and teachers. This document provides the appendices to the technical report "New York City School Survey…

  13. The 1992 Research/Technology report

    NASA Technical Reports Server (NTRS)

    1992-01-01

    The 1992 Research & Technology report is organized so that a broad cross section of the community can readily use it. A short introductory paragraph begins each article and will prove to be an invaluable reference tool for the layperson. The approximately 200 articles summarize the progress made during the year in various technical areas and portray the technical and administrative support associated with Lewis technology programs.

  14. Trends in Articulation Arrangements for Technical and Vocational Education in the South East Asian Region.

    ERIC Educational Resources Information Center

    Haas, Adrian R.

    Trends in articulation arrangements for technical and vocational education (TVE) in the South East Asia region were studied. A key feature of articulation is the existence of pathways that allow graduates of one course of study to progress to other courses. Effective articulation opens up advancement for individuals and helps to create a flexible…

  15. Longitudinal Surveys of Australian Youth (LSAY) 1998 Cohort: Wave 12 (2009)--Frequency Tables. Technical Report 58B

    ERIC Educational Resources Information Center

    National Centre for Vocational Education Research (NCVER), 2010

    2010-01-01

    The Longitudinal Surveys of Australian Youth (LSAY) program studies the progress of several groups of young Australians as they move from school into post-secondary education and work. This technical paper contains the frequency tables for the LSAY 1998 cohort Wave 12 (2009) data set. [For the accompanying questionnaire, "Longitudinal Surveys…

  16. Longitudinal Surveys of Australian Youth (LSAY): 2003 Cohort Wave 7 (2009)--Frequency Tables. Technical Report 57B

    ERIC Educational Resources Information Center

    National Centre for Vocational Education Research (NCVER), 2010

    2010-01-01

    The Longitudinal Surveys of Australian Youth (LSAY) program studies the progress of several groups of young Australians as they move from school into post-secondary education and work. This technical paper contains the frequency tables for the LSAY 2003 cohort Wave 7 (2009) data set. [For the related questionnaire, see ED512164.

  17. Longitudinal Surveys of Australian Youth (LSAY) 2009 Cohort: Wave 3 (2011)--Frequency Tables. Technical Report 72B

    ERIC Educational Resources Information Center

    National Centre for Vocational Education Research (NCVER), 2012

    2012-01-01

    The Longitudinal Surveys of Australian Youth (LSAY) program studies the progress of several groups of young Australians as they move from school into post-secondary education and work. This technical paper contains the frequency tables for the LSAY 2009 cohort Wave 3 (2011) data set. [For the related questionnaire, see ED536306.

  18. Longitudinal Surveys of Australian Youth (LSAY) 2003 Cohort: Wave 7 (2009)--Questionnaire. Technical Report 57A

    ERIC Educational Resources Information Center

    National Centre for Vocational Education Research (NCVER), 2010

    2010-01-01

    The Longitudinal Surveys of Australian Youth (LSAY) program studies the progress of several groups of young Australians as they move from school into post-secondary education and work. This technical paper contains the questionnaire for the LSAY 2003 cohort Wave 7 (2009) data set. [For the related frequency tables, see ED512163.

  19. Making the Good Even Better: Feedback from easyCBM Focus Groups, School Year 2009/2010. Technical Report # 1001

    ERIC Educational Resources Information Center

    Alonzo, Julie; Tindal, Gerald; Lai, Cheng-Fei

    2010-01-01

    This technical report provides a summary of feedback from teachers, administrators, and support personnel who used the easyCBM progress monitoring and benchmark assessment system during school year 2009/2010. Data were gathered from semi-structured focus groups conducted during the 2010 easyCBM August Institute at the University of Oregon. Results…

  20. Longitudinal Surveys of Australian Youth (LSAY): 2006 Cohort Wave 4 (2009)--Frequency Tables. Technical Report 56B

    ERIC Educational Resources Information Center

    National Centre for Vocational Education Research (NCVER), 2010

    2010-01-01

    The Longitudinal Surveys of Australian Youth (LSAY) program studies the progress of several groups of young Australians as they move from school into post-secondary education and work. This technical paper contains the frequency tables for the LSAY 2006 cohort Wave 4 (2009) data set. [For the "Longitudinal Surveys of Australian Youth (LSAY):…

  1. Longitudinal Surveys of Australian Youth (LSAY): 2006 Cohort Wave 4 (2009)--Questionnaire. Technical Report 56A

    ERIC Educational Resources Information Center

    National Centre for Vocational Education Research (NCVER), 2010

    2010-01-01

    The Longitudinal Surveys of Australian Youth (LSAY) program studies the progress of several groups of young Australians as they move from school into post-secondary education and work. This technical paper contains the questionnaire for the LSAY 2006 cohort Wave 4 (2009) data set. [For the "Longitudinal Surveys of Australian Youth (LSAY):…

  2. Establishment of the Center for Advanced Separation Technologies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christopher E. Hull

    2006-09-30

    This Final Technical Report covers the eight sub-projects awarded in the first year and the five projects awarded in the second year of Cooperative Agreement DE-FC26-01NT41091: Establishment of the Center for Advanced Separation Technologies. This work is summarized in the body of the main report: the individual sub-project Technical Progress Reports are attached as Appendices.

  3. A Historical Introduction to Library Education: Problems and Progress to 1951.

    ERIC Educational Resources Information Center

    White, Carl M.

    The growth of libraries and of technical education in the middle of the 19th century led to the organization of Melvil Dewey's School of Library Economy in 1887. The School offered a technical course to replace the apprenticeships then in favor. Its curriculum persisted as the model for library education through 1920. A break with the early form…

  4. Progress Report on Reactivity Analyses (October-December Test Data). Beginning Teacher Evaluation Study. Technical Note Series. Technical Note III-5.

    ERIC Educational Resources Information Center

    Filby, Nikola N.

    The development and refinement of the measures of student achievement in reading and mathematics for the Beginning Teacher Evaluation Study are described. The concept of reactivity to instruction is introduced: the tests used to evaluate instructional processes must be sensitive indicators of classroom learning overtime. Data collection activities…

  5. Review of Web-Based Technical Documentation Processes. FY07 NAEP-QA Special Study Report. TR-08-17

    ERIC Educational Resources Information Center

    Gribben, Monica; Wise, Lauress; Becker, D. E.

    2008-01-01

    Beginning with the 2000 and 2001 National Assessment of Educational Progress (NAEP) assessments, the National Center for Education Statistics (NCES) has made technical documentation available on the worldwide web at http://nces.ed.gov/nationsreportcard/tdw/. The web-based documentation is designed to be less dense and more accessible than prior…

  6. Millimeter-wave passive ultra-compact imaging technology for synthetic vision & mobile platforms

    NASA Technical Reports Server (NTRS)

    Olsen, Randall

    1996-01-01

    Substantial technical progress was made on all of the three high-risk subsystems of this program. The subsystems include dielectric antenna, G-band receiver, and electro-optic image processor. Progress is approximately on-schedule for both the receiver and the electro-optic processor development, while greater than anticipated challenges have been discovered in the dielectric antenna development. Much of the information in this report was covered in greater detail in the One-Year Review Meeting held at TTC on 22 February 1996. The performance goals of the dielectric antenna project are: Scan Angle -- 20 deg. desired; Loss -- 6 dB end to end (3 dB average); Frequency -- 206-218 GHz (6% bandwidth); Beam width -- 0.25 deg.; and Length -- 12 inches. The scan angle requirement was chosen to satisfy the needs of aircraft pilots. This requirement, coupled with the presently limited bandwidth processors (1 GHz state-of-the-art and 12 GHz in development in this program) forces the antenna to be dielectric (high scan angle air-filled waveguide-based antennas would be too lossy and their performance would vary too much as a function of frequency). A high dielectric constant (e.g., 10) was initially chosen for the dielectric material. This choice lead to the following fabrication challenges: total thickness variation (TTV) tolerance is 1 micrometer; coupler spacing tolerance is 1 micrometer; width tolerance is larger, but unknown, and the surfaces must have mirror finish. Also of importance is the difficulty in obtaining raw materials that satisfy the overall length requirement of 12 inches while simultaneously satisfying the above specifications.

  7. Recurrence and Survival Outcomes After Percutaneous Thermal Ablation of Oligometastatic Melanoma.

    PubMed

    White, Mariah L; Atwell, Thomas D; Kurup, A Nicholas; Schmit, Grant D; Carter, Rickey E; Geske, Jennifer R; Kottschade, Lisa A; Pulido, Jose S; Block, Matthew S; Jakub, James W; Callstrom, Matthew R; Markovic, Svetomir N

    2016-03-01

    To evaluate focal treatment of melanoma metastases and to explore whether any potential extended survival benefit exists in a select patient population. All patients who underwent image-guided local thermal ablation of metastatic melanoma over an 11-year period (January 1, 2002, to December 31, 2013) were retrospectively identified using an internally maintained clinical registry. Only patients with oligometastatic stage IV disease amenable to complete ablation of all clinical disease at the time of ablation were included in the analysis. Overall survival and median progression-free survival periods were calculated. Thirty-three patients with primary ocular or nonocular melanoma had 66 metastases treated in the lungs, liver, bones, or soft tissues. Eleven (33%) patients were on systemic medical therapy at the time of the procedure. The median survival time was 3.8 years (range, 0.5-10.5 years), with a 4-year estimated survival of 44.1% (95% CI, 28%-68%). Local recurrence at the ablation site developed in 15.1% (5 of 33) of the patients and 13.6% of the tumors (9 of 66). The median progression-free survival time was 4.4 months (95% CI, 1.4 months to 10.5 years), with an estimated 1-year progression-free survival of 30.3% (95% CI, 18%-51%). A subgroup analysis identified 11 patients with primary ocular melanoma and 22 with nonocular melanoma, with a median survival time of 3.9 years (range, 0.9-4.7 years) and 3.8 years (range, 0.5-10.5 years), respectively (P=.58). There were no major complications and no deaths within 30 days of the procedure. Selective use of image-guided thermal ablation of oligometastatic melanoma may provide results similar to surgical resection in terms of technical effectiveness and oncologic outcomes with minimal risk. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  8. Professional technical standards in colleges and schools of pharmacy.

    PubMed

    Berry, Tricia M; Chichester, Clinton O; Lundquist, Lisa M; Sanoski, Cynthia A; Woodward, Donald A; Worley, Marcia M; Early, Johnnie L

    2011-04-11

    To determine the prevalence, characteristics, and use of professional technical standards among colleges and schools of pharmacy accredited by the Accreditation Council for Pharmacy Education (ACPE). The Web site of every college and school of pharmacy accredited by ACPE was searched to identify information regarding the availability, content, and use of technical standards and to obtain demographic information. Information was obtained from all of the 114 colleges and schools of pharmacy and 67 (59%) had technical standards in place. Common themes for technical standards were: observation; communication; motor; intellectual, conceptual, integrative and quantitative abilities; and behavioral and social attributes. Of those colleges and schools with technical standards, 61 (91%) had standards that addressed all 5 of these themes and 34 (51%) specified that the technical standards were used in their admission, progression, and graduation procedures. More than half of the colleges and schools of pharmacy examined in this study have technical standards; however, 41% have yet to develop and implement them. Colleges and schools of pharmacy looking for guidance in technical standards development could use the technical standards themes identified in this study.

  9. Professional Technical Standards in Colleges and Schools of Pharmacy

    PubMed Central

    Berry, Tricia M.; Chichester, Clinton O.; Sanoski, Cynthia A.; Woodward, Donald A.; Worley, Marcia M.; Early, Johnnie L.

    2011-01-01

    Objective To determine the prevalence, characteristics, and use of professional technical standards among colleges and schools of pharmacy accredited by the Accreditation Council for Pharmacy Education (ACPE). Methods The Web site of every college and school of pharmacy accredited by ACPE was searched to identify information regarding the availability, content, and use of technical standards and to obtain demographic information. Results Information was obtained from all of the 114 colleges and schools of pharmacy and 67 (59%) had technical standards in place. Common themes for technical standards were: observation; communication; motor; intellectual, conceptual, integrative and quantitative abilities; and behavioral and social attributes. Of those colleges and schools with technical standards, 61 (91%) had standards that addressed all 5 of these themes and 34 (51%) specified that the technical standards were used in their admission, progression, and graduation procedures. Conclusion More than half of the colleges and schools of pharmacy examined in this study have technical standards; however, 41% have yet to develop and implement them. Colleges and schools of pharmacy looking for guidance in technical standards development could use the technical standards themes identified in this study. PMID:21655404

  10. Economic growth and decline in mortality in developing countries: an analysis of the World Bank development datasets.

    PubMed

    Renton, A; Wall, M; Lintott, J

    2012-07-01

    The 1999 World Bank report claimed that growth in gross domestic product (GDP) between 1960 and 1990 only accounted for 15% of concomitant growth in life expectancy in developing countries. These findings were used repeatedly by the World Health Organization (WHO) to support a policy shift away from promoting social and economic development, towards vertical technology-driven programmes. This paper updates the 1999 World Bank report using the World Bank's 2005 dataset, providing a new assessment of the relative contribution of economic growth. Time-series analysis. Cross-sectional time-series regression analysis using a random effect model of associations between GDP, education and technical progress and improved health outcomes. The proportion of improvement in health indicators between 1970 and 2000 associated with changes in GDP, education and technical progress was estimated. In 1970, a 1% difference in GDP between countries was associated with 6% difference in female (LEBF) and 5% male (LEBM) life expectancy at birth. By 2000, these values had increased to 14% and 12%, explaining most of the observed health gain. Excluding Europe and Central Asia, the proportion of the increase in LEBF and LEBM attributable to increased GDP was 31% and 33% in the present analysis, vs. 17% and 14%, respectively, estimated by the World Bank. In the poorest countries, higher GDPs were required in 2000 than in 1970 to achieve the same health outcomes. In the poorest countries, socio-economic change is likely to be a more important source of health improvement than technical progress. Technical progress, operating by increasing the size of the effect of a unit of GDP on health, is likely to benefit richer countries more than poorer countries, thereby increasing global health inequalities. Copyright © 2012 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  11. APS 6BM-B Large Volume High Pressure Beamline: A Workhorse for Rock and Mineral Physics

    NASA Astrophysics Data System (ADS)

    Chen, H.; Whitaker, M. L.; Baldwin, K. J.; Huebsch, W. R.; Vaughan, M. T.; Weidner, D. J.

    2017-12-01

    With the inheritance of decades of technical innovations at the NSLS X17B2 Beamline, APS 6BM-B Beamline was established in 2015 and is a dedicated beamline for synchrotron-based large volume high pressure research in earth sciences, especially rock and mineral physics. Currently a 250-ton hydraulic press equipped with a D-DIA module is installed and a Rotational Drickamer Apparatus from Yale University is hosted every cycle, covering a pressure range from crust to lower mantle. 6BM-B operates in white beam mode with an effective energy range of 20-100 keV. Energy dispersive X-ray diffraction data is collected using a 10-element solid state Ge array detector arranged in a circular geometry to allow for the real time assessment of stress. Direct radiographic imaging using Prosillica CCD camera and scintillating YAG crystals yields sample strain and strain rate. In addition to applications in phase transitions, equation of states measurements, sound velocity measurements, this setup is ideal for studies of steady state and dynamic deformation process. In this presentation, technical features and strengths of 6BM-B will be discussed. Most recent progress and science highlights of our user community will be showcased.

  12. Porous silicon for drug delivery applications and theranostics: recent advances, critical review and perspectives.

    PubMed

    Kumeria, Tushar; McInnes, Steven J P; Maher, Shaheer; Santos, Abel

    2017-12-01

    Porous silicon (pSi) engineered by electrochemical etching has been used as a drug delivery vehicle to address the intrinsic limitations of traditional therapeutics. Biodegradability, biocompatibility, and optoelectronic properties make pSi a unique candidate for developing biomaterials for theranostics and photodynamic therapies. This review presents an updated overview about the recent therapeutic systems based on pSi, with a critical analysis on the problems and opportunities that this technology faces as well as highlighting pSi's growing potential. Areas covered: Recent progress in pSi-based research includes drug delivery systems, including biocompatibility studies, drug delivery, theranostics, and clinical trials with the most relevant examples of pSi-based systems presented here. A critical analysis about the technical advantages and disadvantages of these systems is provided along with an assessment on the challenges that this technology faces, including clinical trials and investors' support. Expert opinion: pSi is an outstanding material that could improve existing drug delivery and photodynamic therapies in different areas, paving the way for developing advanced theranostic nanomedicines and incorporating payloads of therapeutics with imaging capabilities. However, more extensive in-vivo studies are needed to assess the feasibility and reliability of this technology for clinical practice. The technical and commercial challenges that this technology face are still uncertain.

  13. Quantitative imaging biomarkers: Effect of sample size and bias on confidence interval coverage.

    PubMed

    Obuchowski, Nancy A; Bullen, Jennifer

    2017-01-01

    Introduction Quantitative imaging biomarkers (QIBs) are being increasingly used in medical practice and clinical trials. An essential first step in the adoption of a quantitative imaging biomarker is the characterization of its technical performance, i.e. precision and bias, through one or more performance studies. Then, given the technical performance, a confidence interval for a new patient's true biomarker value can be constructed. Estimating bias and precision can be problematic because rarely are both estimated in the same study, precision studies are usually quite small, and bias cannot be measured when there is no reference standard. Methods A Monte Carlo simulation study was conducted to assess factors affecting nominal coverage of confidence intervals for a new patient's quantitative imaging biomarker measurement and for change in the quantitative imaging biomarker over time. Factors considered include sample size for estimating bias and precision, effect of fixed and non-proportional bias, clustered data, and absence of a reference standard. Results Technical performance studies of a quantitative imaging biomarker should include at least 35 test-retest subjects to estimate precision and 65 cases to estimate bias. Confidence intervals for a new patient's quantitative imaging biomarker measurement constructed under the no-bias assumption provide nominal coverage as long as the fixed bias is <12%. For confidence intervals of the true change over time, linearity must hold and the slope of the regression of the measurements vs. true values should be between 0.95 and 1.05. The regression slope can be assessed adequately as long as fixed multiples of the measurand can be generated. Even small non-proportional bias greatly reduces confidence interval coverage. Multiple lesions in the same subject can be treated as independent when estimating precision. Conclusion Technical performance studies of quantitative imaging biomarkers require moderate sample sizes in order to provide robust estimates of bias and precision for constructing confidence intervals for new patients. Assumptions of linearity and non-proportional bias should be assessed thoroughly.

  14. Overview about the localization of nanoparticles in tissue and cellular context by different imaging techniques

    PubMed Central

    Ostrowski, Anja; Nordmeyer, Daniel; Boreham, Alexander; Holzhausen, Cornelia; Mundhenk, Lars; Graf, Christina; Meinke, Martina C; Vogt, Annika; Hadam, Sabrina; Lademann, Jürgen; Rühl, Eckart; Alexiev, Ulrike

    2015-01-01

    Summary The increasing interest and recent developments in nanotechnology pose previously unparalleled challenges in understanding the effects of nanoparticles on living tissues. Despite significant progress in in vitro cell and tissue culture technologies, observations on particle distribution and tissue responses in whole organisms are still indispensable. In addition to a thorough understanding of complex tissue responses which is the domain of expert pathologists, the localization of particles at their sites of interaction with living structures is essential to complete the picture. In this review we will describe and compare different imaging techniques for localizing inorganic as well as organic nanoparticles in tissues, cells and subcellular compartments. The visualization techniques include well-established methods, such as standard light, fluorescence, transmission electron and scanning electron microscopy as well as more recent developments, such as light and electron microscopic autoradiography, fluorescence lifetime imaging, spectral imaging and linear unmixing, superresolution structured illumination, Raman microspectroscopy and X-ray microscopy. Importantly, all methodologies described allow for the simultaneous visualization of nanoparticles and evaluation of cell and tissue changes that are of prime interest for toxicopathologic studies. However, the different approaches vary in terms of applicability for specific particles, sensitivity, optical resolution, technical requirements and thus availability, and effects of labeling on particle properties. Specific bottle necks of each technology are discussed in detail. Interpretation of particle localization data from any of these techniques should therefore respect their specific merits and limitations as no single approach combines all desired properties. PMID:25671170

  15. Radiology's Achilles' heel: error and variation in the interpretation of the Röntgen image.

    PubMed

    Robinson, P J

    1997-11-01

    The performance of the human eye and brain has failed to keep pace with the enormous technical progress in the first full century of radiology. Errors and variations in interpretation now represent the weakest aspect of clinical imaging. Those interpretations which differ from the consensus view of a panel of "experts" may be regarded as errors; where experts fail to achieve consensus, differing reports are regarded as "observer variation". Errors arise from poor technique, failures of perception, lack of knowledge and misjudgments. Observer variation is substantial and should be taken into account when different diagnostic methods are compared; in many cases the difference between observers outweighs the difference between techniques. Strategies for reducing error include attention to viewing conditions, training of the observers, availability of previous films and relevant clinical data, dual or multiple reporting, standardization of terminology and report format, and assistance from computers. Digital acquisition and display will probably not affect observer variation but the performance of radiologists, as measured by receiver operating characteristic (ROC) analysis, may be improved by computer-directed search for specific image features. Other current developments show that where image features can be comprehensively described, computer analysis can replace the perception function of the observer, whilst the function of interpretation can in some cases be performed better by artificial neural networks. However, computer-assisted diagnosis is still in its infancy and complete replacement of the human observer is as yet a remote possibility.

  16. Characterization of PET/CT images using texture analysis: the past, the present… any future?

    PubMed

    Hatt, Mathieu; Tixier, Florent; Pierce, Larry; Kinahan, Paul E; Le Rest, Catherine Cheze; Visvikis, Dimitris

    2017-01-01

    After seminal papers over the period 2009 - 2011, the use of texture analysis of PET/CT images for quantification of intratumour uptake heterogeneity has received increasing attention in the last 4 years. Results are difficult to compare due to the heterogeneity of studies and lack of standardization. There are also numerous challenges to address. In this review we provide critical insights into the recent development of texture analysis for quantifying the heterogeneity in PET/CT images, identify issues and challenges, and offer recommendations for the use of texture analysis in clinical research. Numerous potentially confounding issues have been identified, related to the complex workflow for the calculation of textural features, and the dependency of features on various factors such as acquisition, image reconstruction, preprocessing, functional volume segmentation, and methods of establishing and quantifying correspondences with genomic and clinical metrics of interest. A lack of understanding of what the features may represent in terms of the underlying pathophysiological processes and the variability of technical implementation practices makes comparing results in the literature challenging, if not impossible. Since progress as a field requires pooling results, there is an urgent need for standardization and recommendations/guidelines to enable the field to move forward. We provide a list of correct formulae for usual features and recommendations regarding implementation. Studies on larger cohorts with robust statistical analysis and machine learning approaches are promising directions to evaluate the potential of this approach.

  17. Critical Review of Technical Questions Facing Low Impact Development and Green Infrastructure: A Perspective from the Great Plains.

    PubMed

    Vogel, Jason R; Moore, Trisha L; Coffman, Reid R; Rodie, Steven N; Hutchinson, Stacy L; McDonough, Kelsey R; McLemore, Alex J; McMaine, John T

    2015-09-01

    Since its inception, Low Impact Development (LID) has become part of urban stormwater management across the United States, marking progress in the gradual transition from centralized to distributed runoff management infrastructure. The ultimate goal of LID is full, cost-effective implementation to maximize watershed-scale ecosystem services and enhance resilience. To reach that goal in the Great Plains, the multi-disciplinary author team presents this critical review based on thirteen technical questions within the context of regional climate and socioeconomics across increasing complexities in scale and function. Although some progress has been made, much remains to be done including continued basic and applied research, development of local LID design specifications, local demonstrations, and identifying funding mechanisms for these solutions. Within the Great Plains and beyond, by addressing these technical questions within a local context, the goal of widespread acceptance of LID can be achieved, resulting in more effective and resilient stormwater management.

  18. Do failures in non-technical skills contribute to fatal medical accidents in Japan? A review of the 2010-2013 national accident reports.

    PubMed

    Uramatsu, Masashi; Fujisawa, Yoshikazu; Mizuno, Shinya; Souma, Takahiro; Komatsubara, Akinori; Miki, Tamotsu

    2017-02-16

    We sought to clarify how large a proportion of fatal medical accidents can be considered to be caused by poor non-technical skills, and to support development of a policy to reduce number of such accidents by making recommendations about possible training requirements. Summaries of reports of fatal medical accidents, published by the Japan Medical Safety Research Organization, were reviewed individually. Three experienced clinicians and one patient safety expert conducted the reviews to determine the cause of death. Views of the patient safety expert were given additional weight in the overall determination. A total of 73 summary reports of fatal medical accidents were reviewed. These reports had been submitted by healthcare organisations across Japan to the Japan Medical Safety Research Organization between April 2010 and March 2013. The cause of death in fatal medical accidents, categorised into technical skills, non-technical skills and inevitable progress of disease were evaluated. Non-technical skills were further subdivided into situation awareness, decision making, communication, team working, leadership, managing stress and coping with fatigue. Overall, the cause of death was identified as non-technical skills in 34 cases (46.6%), disease progression in 33 cases (45.2%) and technical skills in two cases (5.5%). In two cases, no consensual determination could be achieved. Further categorisation of cases of non-technical skills were identified as 14 cases (41.2%) of problems with situation awareness, eight (23.5%) with team working and three (8.8%) with decision making. These three subcategories, or combinations of them, were identified as the cause of death in 33 cases (97.1%). Poor non-technical skills were considered to be a significant cause of adverse events in nearly half of the fatal medical accidents examined. Improving non-technical skills may be effective for reducing accidents, and training in particular subcategories of non-technical skills may be especially relevant. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  19. Next Generation Attenuation Relationships for the Eastern United States (NGA-East)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mahin, Stephen; Bozorgnia, Yousef

    2016-04-11

    This is a progress report to DOE for project Next Generation Attenuation for Central & Eastern US (NGA-East).This progress report consists of numerous monthly progress segments starting June 1, 2010 until December 31, 2015. Please note: the December 2015 progress report was issued in January 2016 due to the final university financial reporting at the end of this project. For each month, there is a technical progress list, and an update on the financial progress of the project. As you know, this project is jointly funded by the DOE, US Nuclear Regulatory Commission (NRC) and Electric Power Research Institute (EPRI).more » Thus, each segment includes financial progress for these three funding agencies.« less

  20. Technical Feasibility Aspects of the Geothermal Resource Reporting Methodology (GRRM)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Badgett, Alex; Young, Katherine R; Dobson, Patrick F.

    This paper reviews the technical assessment of the Geothermal Research Reporting Methodology (GRRM, http://en.openei.org/wiki/GRRM) being developed for reporting geothermal resources and project progress. The goal of the methodology is to provide the U.S. Department of Energy's Geothermal Technologies Office (GTO) with a consistent and comprehensible means of evaluating the impacts of its funding programs. The GRRM is designed to provide uniform assessment criteria for geothermal resource grades and developmental phases of geothermal resource exploration and development. This resource grade system provides information on twelve attributes of geothermal resource locations (e.g., temperature, permeability, land access) to indicate potential for geothermal development.more » The GTO plans to use these Protocols to help quantitatively identify the greatest barriers to geothermal development, develop measureable program goals that will have the greatest impact to geothermal deployment, objectively evaluate proposals based (in part) on a project's ability to contribute to program goals, monitor project progress, and report on GTO portfolio performance. The GRRM assesses three areas of geothermal potential: geological, socio-economic, and technical. Previous work and publications have discussed the work done on the geological aspects of this methodology (Young et al. 2015c); this paper details the development of the technical assessment of the GRRM. Technical development attributes considered include: reservoir management, drilling, logistics, and power conversion.« less

  1. Novel Developments in Instrumentation for PET Imaging

    NASA Astrophysics Data System (ADS)

    Karp, Joel

    2013-04-01

    Advances in medical imaging, in particular positron emission tomography (PET), have been based on technical developments in physics and instrumentation that have common foundations with detection systems used in other fields of physics. New detector materials are used in PET systems that maximize efficiency, timing characteristics and robustness, and which lead to improved image quality and quantitative accuracy for clinical imaging. Time of flight (TOF) techniques are now routinely used in commercial PET scanners that combine physiological imaging with anatomical imaging provided by x-ray computed tomography. Using new solid-state photo-sensors instead of traditional photo-multiplier tubes makes it possible to combine PET with magnetic resonance imaging which is a significant technical challenge, but one that is creating new opportunities for both research and clinical applications. An overview of recent advances in instrumentation, such as TOF and PET/MR will be presented, along with examples of imaging studies to demonstrate the impact on patient care and basic research of diseases.

  2. Humeral stress edema: an injury in overhead athletes quarterback with humeral "shin" splints-a case report.

    PubMed

    Alpert, Justin; Flannery, Robert; Epstein, Robert; Monaco, Robert; Prendergast, Nancy

    2014-09-01

    Stress injury to the distal humerus has been reported as a cause of chronic arm pain among competitive tennis players. As the serve is technically similar to an overhead throwing motion, it is conceivable that this injury could occur in other overhead athletes. Overuse injuries, including rotator cuff tears, ulnar collateral ligament injuries, and joint sprains have routinely been reported in quarterbacks, but there are few reported cases of upper extremity bony stress injuries in these athletes. Magnetic resonance imaging aids in the diagnostic evaluation of an upper extremity injury as it can identify numerous structural injuries and early stress changes within bone. Accurately diagnosing stress reactions helps prevent progression toward stress fracture, which is possible if conservative measures are initiated early in the rehabilitation period. In this article, we report the case of an elite college quarterback who presented with localized elbow pain while throwing.

  3. Cerebral blood flow measured by arterial spin labeling MRI at resting state in normal aging and Alzheimer's disease.

    PubMed

    Zhang, Nan; Gordon, Marc L; Goldberg, Terry E

    2017-01-01

    Arterial spin labeling (ASL) magnetic resonance imaging uses arterial blood water as an endogenous tracer to measure cerebral blood flow (CBF). In this review, based on ASL studies in the resting state, we discuss state-of-the-art technical and data processing improvements in ASL, and ASL CBF changes in normal aging, mild cognitive impairment (MCI), Alzheimer's disease (AD), and other types of dementia. We propose that vascular and AD risk factors should be considered when evaluating CBF changes in aging, and that other validated biomarkers should be used as inclusion criteria or covariates when evaluating CBF changes in MCI and AD. With improvements in hardware and experimental design, ASL is proving to be an increasingly promising tool for exploring pathogenetic mechanisms, early detection, monitoring disease progression and pharmacological response, and differential diagnosis of AD. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Understanding of Leaf Development-the Science of Complexity.

    PubMed

    Malinowski, Robert

    2013-06-25

    The leaf is the major organ involved in light perception and conversion of solar energy into organic carbon. In order to adapt to different natural habitats, plants have developed a variety of leaf forms, ranging from simple to compound, with various forms of dissection. Due to the enormous cellular complexity of leaves, understanding the mechanisms regulating development of these organs is difficult. In recent years there has been a dramatic increase in the use of technically advanced imaging techniques and computational modeling in studies of leaf development. Additionally, molecular tools for manipulation of morphogenesis were successfully used for in planta verification of developmental models. Results of these interdisciplinary studies show that global growth patterns influencing final leaf form are generated by cooperative action of genetic, biochemical, and biomechanical inputs. This review summarizes recent progress in integrative studies on leaf development and illustrates how intrinsic features of leaves (including their cellular complexity) influence the choice of experimental approach.

  5. Understanding of Leaf Development—the Science of Complexity

    PubMed Central

    Malinowski, Robert

    2013-01-01

    The leaf is the major organ involved in light perception and conversion of solar energy into organic carbon. In order to adapt to different natural habitats, plants have developed a variety of leaf forms, ranging from simple to compound, with various forms of dissection. Due to the enormous cellular complexity of leaves, understanding the mechanisms regulating development of these organs is difficult. In recent years there has been a dramatic increase in the use of technically advanced imaging techniques and computational modeling in studies of leaf development. Additionally, molecular tools for manipulation of morphogenesis were successfully used for in planta verification of developmental models. Results of these interdisciplinary studies show that global growth patterns influencing final leaf form are generated by cooperative action of genetic, biochemical, and biomechanical inputs. This review summarizes recent progress in integrative studies on leaf development and illustrates how intrinsic features of leaves (including their cellular complexity) influence the choice of experimental approach. PMID:27137383

  6. [The use of the "cine-technic" in the MRT diagnosis of the temporomandibular joint].

    PubMed

    Vogl, T J; Eberhard, D; Weigl, P; Assal, J; Randzio, J

    1992-03-01

    A new cine-technique in a prospective study using rapid gradient echo sequences was evaluated for the MRT investigation of the temporo-mandibular joint. A newly developed hydraulic apparatus was used to produce progressive opening of the jaw and MRT appearances were recorded during predetermined points of mandibular movement. The investigation included 16 normals and 34 patients. A modified gradient echo sequence was combined with an optimised surface coil or a special double coil and this provided good spatial resolution of the articular disc and of the muscular and bony structure. Amongst the abnormal findings were luxation of the disc (15 cases), tears in the disc (5 cases), late effects of internal derangements (12 cases) and condylar hypermotility (7 cases). The new cine-technique provides specific images in any chosen position of the mandible depending on the clinical disability of the patient.

  7. Preliminary Investigations of the Application of the Early Communication Indicator (ECI) for Infants and Toddlers

    ERIC Educational Resources Information Center

    Greenwood, Charles R.; Carta, Judith J.; Walker, Dale; Hughes, Kere; Weathers, Mary

    2006-01-01

    Early interventionists are accountable for the progress of children receiving their services. Technically adequate measures of the progress of individual children are needed. While the Early Communication Indicator (ECI) for infants and toddlers is one such measure, data to support its use are limited to a single research report. In this…

  8. Curriculum-Based Measurement in Science Learning: Vocabulary-Matching as an Indicator of Performance and Progress

    ERIC Educational Resources Information Center

    Espin, Christine A.; Busch, Todd W.; Lembke, Erica S.; Hampton, David D.; Seo, Kyounghee; Zukowski, Beth A.

    2013-01-01

    The technical adequacy of curriculum-based measures in the form of short and simple vocabulary-matching probes to predict students' performance and progress in science at the secondary level was investigated. Participants were 198 seventh-grade students from 10 science classrooms. Curriculum-based measurements (CBM) were 5-min vocabulary-matching…

  9. Technical Adequacy of Early Numeracy Curriculum-Based Progress Monitoring Measures for Kindergarten and First-Grade Students

    ERIC Educational Resources Information Center

    Hampton, David D.; Lembke, Erica S.; Lee, Young-Sun; Pappas, Sandra; Chiong, Cynthia; Ginsburg, Herbert P.

    2012-01-01

    The purpose of this study was to examine six early numeracy measures used to monitor the mathematics progress of kindergarten and first-grade students. Seventy-one kindergarten students and 75 first-grade students were administered the measures each week. Delayed-alternate form reliability was adequate for instructional decision making on some…

  10. Jet Crackle

    DTIC Science & Technology

    2015-06-23

    DISTRIBUTION/AVAILABILITY STATEMENT DISTRIBUTION A 13. SUPPLEMENTARY NOTES 14. ABSTRACT Fighter jets and other aircraft with high specific thrust engines...interim, memorandum, master’s thesis , progress, quarterly, research, special, group study, etc. 3. DATES COVERED. Indicate the time during which the...State the type of report, such as final, technical, interim, memorandum, master’s thesis , progress, quarterly, research, special, group study, etc

  11. Reading Achievement in Disadvantaged Children as a Consequence of Non Verbal Perceptual Training. Final Technical Progress Report.

    ERIC Educational Resources Information Center

    Elkind, David; Deblinger, Jo Ann

    The theoretical orientation based on perceptual development, proposed by Piaget in 1961, is the starting point of this investigation. According to Piaget, the perception of the young child is "centered" on dominant aspects of the field. With maturity, perception becomes "decentered" and progressively freed from the field. The…

  12. Curriculum-Based Measurement of Reading Progress Monitoring: The Importance of Growth Magnitude and Goal Setting in Decision Making

    ERIC Educational Resources Information Center

    Van Norman, Ethan R.; Christ, Theodore J.; Newell, Kirsten W.

    2017-01-01

    Research regarding the technical adequacy of growth estimates from curriculum-based measurement of reading progress monitoring data suggests that current decision-making frameworks are likely to yield inaccurate recommendations unless data are collected for extensive periods of time. Instances where data may not need to be collected for long…

  13. Monitoring Student Progress and Publicising the Results. Information Bank Number 1270.

    ERIC Educational Resources Information Center

    Jones, D. T. L.

    Arguing that assessments of student progress describe the consequences of the interaction of the multitude of elements that make up the educational system, this paper examines the three-tiered assessment system used at Redhill Technical College (RTC), in Surrey, England, to fulfill diagnostic and motivational functions for the college as a whole.…

  14. Career and Technical Education in the Crossroads of Change

    ERIC Educational Resources Information Center

    Quailey, Janice

    2012-01-01

    Career and technical education (CTE) is faced with numerous forces that may impact its future. A variety of forces directly or indirectly affect CTE, ranging from the persisting stigma or negative image of career and technical education, the schools' curricular structure and requirements, along with federal laws such as No Child Left Behind (NCLB)…

  15. Treatment of lung tumours with high-energy microwave ablation: a single-centre experience.

    PubMed

    Ierardi, Anna Maria; Coppola, Andrea; Lucchina, Natalie; Carrafiello, Gianpaolo

    2017-01-01

    The purpose of our study is to report safety, technical success, effectiveness, local progression-free survival (LPFS) and overall survival of percutaneous microwave ablation (MWA) to treat lung tumours unsuitable for surgery. Nineteen patients with thirty-one tumours (mean diameter 2.4 cm) underwent percutaneous MWA in 28 sessions. Microwave ablation was carried out using a 2450-MHz generator (Emprint/Covidien, Boulder, CO, USA). Procedures were performed under cone-beam CT (CBCT) and under fluoro-CT (one session) guidance. Safety, technical success, effectiveness, LPFS and overall survival (OS) were evaluated. Safety was defined as the frequency of major and minor complications. The efficacy was evaluated on the basis of imaging characteristics, using RECIST criteria. CT follow-up was performed at 1, 3 and 6 months and yearly. LPFS was defined as the interval between MWA treatment and evidence of local recurrence, if there was any. OS was defined as the percentage of patients who were still alive. We registered one major complication (purulent hydro-pneumothorax). Minor complications were spontaneously resolved (pneumothorax and perilesional haemorrhagic effusion). Technical success was 100%. Residual disease was registered in two cases, one of whom was retreated. Complete ablation was obtained in the remaining cases (90.3%). During available follow-up (mean 9.6 months), 9/31 tumours demonstrated local recurrence. Five tumours were retreated, and none of them presented residual disease during follow-up (LPFS 22.6%). Overall survival was 93.8%. Percutaneous high-energy MWA is a safe, effective and confident technique to treat lung tumours not suitable for surgery.

  16. Competency Testing for Pediatric Cardiology Fellows Learning Transthoracic Echocardiography: Implementation, Fellow Experience, and Lessons Learned.

    PubMed

    Levine, Jami C; Geva, Tal; Brown, David W

    2015-12-01

    There is currently great interest in measuring trainee competency at all levels of medical education. In 2007, we implemented a system for assessing cardiology fellows' progress in attaining imaging skills. This paradigm could be adapted for use by other cardiology programs. Evaluation consisted of a two-part exercise performed after years 1 and 2 of pediatric cardiology training. Part 1: a directly observed evaluation of technical skills as fellows imaged a normal subject (year 1) and a patient with complex heart disease (year 2). Part 2: fellows interpreted and wrote reports for two echocardiograms illustrating congenital heart disease. These were graded for accuracy and facility with communicating pertinent data. After 5 years of testing, fellows were surveyed about their experience. In 5 years, 40 fellows were tested at least once. Testing identified four fellows who underperformed on the technical portion and four on the interpretive portion. Surveys were completed by 33 fellows (83 %). Most (67 %) felt that intermittent observation by faculty was inadequate for assessing skills and that procedural volume was a poor surrogate for competency (58 %). Posttest feedback was constructive and valuable for 90, and 70 % felt the process helped them set goals for skill improvement. Overall, fellows felt this testing was fair and should continue. Fellow performance and responses identified programmatic issues that were creating barriers to learning. We describe a practical test to assess competency for cardiology fellows learning echocardiography. This paradigm is feasible, has excellent acceptance among trainees, and identifies trainees who need support. Materials developed could be easily adapted to help track upcoming ACGME-mandated metrics.

  17. Molecular imaging of malignant tumor metabolism: whole-body image fusion of DWI/CT vs. PET/CT.

    PubMed

    Reiner, Caecilia S; Fischer, Michael A; Hany, Thomas; Stolzmann, Paul; Nanz, Daniel; Donati, Olivio F; Weishaupt, Dominik; von Schulthess, Gustav K; Scheffel, Hans

    2011-08-01

    To prospectively investigate the technical feasibility and performance of image fusion for whole-body diffusion-weighted imaging (wbDWI) and computed tomography (CT) to detect metastases using hybrid positron emission tomography/computed tomography (PET/CT) as reference standard. Fifty-two patients (60 ± 14 years; 18 women) with different malignant tumor disease examined by PET/CT for clinical reasons consented to undergo additional wbDWI at 1.5 Tesla. WbDWI was performed using a diffusion-weighted single-shot echo-planar imaging during free breathing. Images at b = 0 s/mm(2) and b = 700 s/mm(2) were acquired and apparent diffusion coefficient (ADC) maps were generated. Image fusion of wbDWI and CT (from PET/CT scan) was performed yielding for wbDWI/CT fused image data. One radiologist rated the success of image fusion and diagnostic image quality. The presence or absence of metastases on wbDWI/CT fused images was evaluated together with the separate wbDWI and CT images by two different, independent radiologists blinded to results from PET/CT. Detection rate and positive predictive values for diagnosing metastases was calculated. PET/CT examinations were used as reference standard. PET/CT identified 305 malignant lesions in 39 of 52 (75%) patients. WbDWI/CT image fusion was technically successful and yielded diagnostic image quality in 73% and 92% of patients, respectively. Interobserver agreement for the evaluation of wbDWI/CT images was κ = 0.78. WbDWI/CT identified 270 metastases in 43 of 52 (83%) patients. Overall detection rate and positive predictive value of wbDWI/CT was 89% (95% CI, 0.85-0.92) and 94% (95% CI, 0.92-0.97), respectively. WbDWI/CT image fusion is technically feasible in a clinical setting and allows the diagnostic assessment of metastatic tumor disease detecting nine of 10 lesions as compared with PET/CT. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  18. Novel Applications of Radionuclide Imaging in Peripheral Vascular Disease

    PubMed Central

    Stacy, Mitchel R.; Sinusas, Albert J.

    2015-01-01

    Peripheral vascular disease (PVD) is a progressive atherosclerotic disease that leads to stenosis or occlusion of blood vessels supplying the lower extremities. Current diagnostic imaging techniques commonly focus on evaluation of anatomy or blood flow at the macrovascular level and do not permit assessment of the underlying pathophysiology associated with disease progression or treatment response. Molecular imaging with radionuclide-based approaches, such as PET and SPECT, can offer novel insight into PVD by providing non-invasive assessment of biological processes such as angiogenesis and atherosclerosis. This review discusses emerging radionuclide-based imaging approaches that have potential clinical applications in the evaluation of PVD progression and treatment. PMID:26590787

  19. Definitions for a common standard for 2D speckle tracking echocardiography: consensus document of the EACVI/ASE/Industry Task Force to standardize deformation imaging.

    PubMed

    Voigt, Jens-Uwe; Pedrizzetti, Gianni; Lysyansky, Peter; Marwick, Tom H; Houle, Hélène; Baumann, Rolf; Pedri, Stefano; Ito, Yasuhiro; Abe, Yasuhiko; Metz, Stephen; Song, Joo Hyun; Hamilton, Jamie; Sengupta, Partho P; Kolias, Theodore J; d'Hooge, Jan; Aurigemma, Gerard P; Thomas, James D; Badano, Luigi Paolo

    2015-02-01

    Recognizing the critical need for standardization in strain imaging, in 2010, the European Association of Echocardiography (now the European Association of Cardiovascular Imaging, EACVI) and the American Society of Echocardiography (ASE) invited technical representatives from all interested vendors to participate in a concerted effort to reduce intervendor variability of strain measurement. As an initial product of the work of the EACVI/ASE/Industry initiative to standardize deformation imaging, we prepared this technical document which is intended to provide definitions, names, abbreviations, formulas, and procedures for calculation of physical quantities derived from speckle tracking echocardiography and thus create a common standard. Copyright © 2015 American Society of Echocardiography. All rights reserved.

  20. Digital radiography: optimization of image quality and dose using multi-frequency software.

    PubMed

    Precht, H; Gerke, O; Rosendahl, K; Tingberg, A; Waaler, D

    2012-09-01

    New developments in processing of digital radiographs (DR), including multi-frequency processing (MFP), allow optimization of image quality and radiation dose. This is particularly promising in children as they are believed to be more sensitive to ionizing radiation than adults. To examine whether the use of MFP software reduces the radiation dose without compromising quality at DR of the femur in 5-year-old-equivalent anthropomorphic and technical phantoms. A total of 110 images of an anthropomorphic phantom were imaged on a DR system (Canon DR with CXDI-50 C detector and MLT[S] software) and analyzed by three pediatric radiologists using Visual Grading Analysis. In addition, 3,500 images taken of a technical contrast-detail phantom (CDRAD 2.0) provide an objective image-quality assessment. Optimal image-quality was maintained at a dose reduction of 61% with MLT(S) optimized images. Even for images of diagnostic quality, MLT(S) provided a dose reduction of 88% as compared to the reference image. Software impact on image quality was found significant for dose (mAs), dynamic range dark region and frequency band. By optimizing image processing parameters, a significant dose reduction is possible without significant loss of image quality.

  1. Magnetic Earth Ionosphere Resonant Frequencies

    NASA Technical Reports Server (NTRS)

    Spaniol, Craig

    1994-01-01

    The Community College Division is pleased to report progress of NASA funded research at West Virginia State College. During this reporting period, the project research group has continued with activities to develop instrumentation capability designed to monitor resonant cavity frequencies in the atmospheric region between the Earth's surface and the ionosphere. In addition, the project's principal investigator, Dr. Craig Spaniol, and NASA technical officer, Dr. John Sutton, have written and published technical papers intended to expand the scientific and technical framework needed for project research. This research continues to provide an excellent example of government and education working together to provide significant research in the college environment. This cooperative effort has provided many students with technical project work which compliments their education.

  2. 48 CFR 742.1170-1 - General.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... MANAGEMENT CONTRACT ADMINISTRATION Production, Surveillance, and Reporting 742.1170-1 General. Performance... cognizant technical officer, to maintain adequate knowledge of the contractor's activities and progress in...

  3. 48 CFR 742.1170-1 - General.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... MANAGEMENT CONTRACT ADMINISTRATION Production, Surveillance, and Reporting 742.1170-1 General. Performance... cognizant technical officer, to maintain adequate knowledge of the contractor's activities and progress in...

  4. 48 CFR 742.1170-1 - General.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... MANAGEMENT CONTRACT ADMINISTRATION Production, Surveillance, and Reporting 742.1170-1 General. Performance... cognizant technical officer, to maintain adequate knowledge of the contractor's activities and progress in...

  5. 48 CFR 742.1170-1 - General.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... MANAGEMENT CONTRACT ADMINISTRATION Production, Surveillance, and Reporting 742.1170-1 General. Performance... cognizant technical officer, to maintain adequate knowledge of the contractor's activities and progress in...

  6. Access and Success for System Goals for People of Color in Washington Community and Technical Colleges: Progress Report. Research Report No. 05-3

    ERIC Educational Resources Information Center

    Washington State Board for Community and Technical Colleges, 2005

    2005-01-01

    This report is designed to provide information for readers, promote discussion, and set the stage for future initiatives to address outcomes for people of color. The data provided speaks to the success that Washington's community and technical colleges have achieved in increasing higher education access and participation for students of color. It…

  7. Internal Consistency of General Outcome Measures in Grades 1-8. Technical Report # 0915

    ERIC Educational Resources Information Center

    Anderson, Daniel; Tindal, Gerald; Alonzo, Julie

    2009-01-01

    We developed alternate forms of a math test for use in both screening students at risk of failure and monitoring their progress over time. In this technical report, we present results of the screener, used in the fall of 2009. The 48-item test was aligned to the National Council of Teachers of Mathematics (NCTM) Curriculum Focal Point Standards…

  8. Career and Technical Education: States Aligning Programs to Meet Workforce Needs. The Progress of Education Reform. Volume 15, Number 2

    ERIC Educational Resources Information Center

    Zinth, Jennifer Dounay

    2014-01-01

    Across the 50 states, career and technical education (CTE) programs at the K-12 and postsecondary levels have seen enormous policy action - 2013 alone saw at least 78 substantive policy changes via legislation, state board rules and executive orders specific to CTE and workforce development. What are the drivers behind this sudden policymaker…

  9. Viewing Golgi structure and function from a different perspective--insights from electron tomography.

    PubMed

    Marsh, Brad J; Pavelka, Margit

    2013-01-01

    Historically, ultrastructural investigations, which have focused on elucidating the biological idiosyncrasies of the Golgi apparatus, have tended towards oversimplified or fallacious hypotheses when postulating how the Golgi apparatus reorganizes itself both structurally and functionally to fulfill the plethora of cellular processes underpinned by this complex organelle. Key questions are still unanswered with regard to how changes in Golgi architecture correlate so reproducibly to changes in its functional priorities under different physiological conditions or experimental perturbations. This fact alone serves to highlight how the technical limitations associated with conventional two-dimensional imaging approaches employed in the past failed to adequately capture the extraordinary complexity of the Golgi's three-dimensional (3D) structure-now a hallmark of this challenging organelle. Consequently, this has hampered progress towards developing a clear understanding of how changes in its structure and function typically occur in parallel. In this chapter, we highlight but a few of the significant new insights regarding variations in the Golgi's structure-function relationships that have been afforded over recent years through advanced electron microscopic techniques for 3D image reconstruction, commonly referred to as electron tomography. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Artificial grammar learning meets formal language theory: an overview

    PubMed Central

    Fitch, W. Tecumseh; Friederici, Angela D.

    2012-01-01

    Formal language theory (FLT), part of the broader mathematical theory of computation, provides a systematic terminology and set of conventions for describing rules and the structures they generate, along with a rich body of discoveries and theorems concerning generative rule systems. Despite its name, FLT is not limited to human language, but is equally applicable to computer programs, music, visual patterns, animal vocalizations, RNA structure and even dance. In the last decade, this theory has been profitably used to frame hypotheses and to design brain imaging and animal-learning experiments, mostly using the ‘artificial grammar-learning’ paradigm. We offer a brief, non-technical introduction to FLT and then a more detailed analysis of empirical research based on this theory. We suggest that progress has been hampered by a pervasive conflation of distinct issues, including hierarchy, dependency, complexity and recursion. We offer clarifications of several relevant hypotheses and the experimental designs necessary to test them. We finally review the recent brain imaging literature, using formal languages, identifying areas of convergence and outstanding debates. We conclude that FLT has much to offer scientists who are interested in rigorous empirical investigations of human cognition from a neuroscientific and comparative perspective. PMID:22688631

  11. New 50-M-Class Single Dish Telescope: Large Submillimeter Telescope (LST)

    NASA Astrophysics Data System (ADS)

    Kawabe, Ryohei

    2018-01-01

    We report on the plan to construct a 50 m class millimeter (mm) and sub-mm single dish telescope, the Large Submillimeter Telescope (LST). The telescope is optimized for wide-area imaging and spectroscopic surveys in the 70 to 420 GHz main frequency range, which just covers main atmospheric windows at millimeter and submillimeter wavelengths for good observing sites such as the ALMA site in Chile. We also target observations at higher frequencies of up to 1 THz, using an inner part high-precision surface. Active surface control is required in order to correct gravitational and thermal deformations of the surface. The LST will facilitate new discovery spaces such as wide-field imaging with both continuum and spectral lines, along with new developments for time domain science. With exploiting synergy with ALMA and other telescopes, LST can contribute to a wide range of topics in astronomy and astrophysics, e.g., astrochemistry, star formation in the Galaxy and galaxies, evolution of galaxy clusters via SZ effect. We also report the recent progress on the technical study, e.g., the tentative study of the surface error budget and challenges to correction for the wind-load effect.

  12. [Role of sentinel lymph nodes and lymphatic mapping of colorectal cancer].

    PubMed

    Ivanov, K; Kolev, N; Ignatov, V; Temelkov, T; Madzhov, R

    2005-01-01

    The accuracy of staging of colorectal cancer is dependable of number of lymph nodes, colected and investegated from the pathologist. Moreover 50% of newfounded cases with colorectal cancer are diagnosed as I or II stage of the desease. Between 15% and 20% of these patients develop regional or distant metastases around 5 years after the examination, despite of the radical surgery. This may be due to pathological "understaging" (decrease of the stage), becouse of missed micrometastases, which size often is smaller than 5 mm. High accurate and specific pathologoanatomical methods for "ultrastaging" are cost-expensive, therefore their selective application to labeled sentinel lymph nodes has a economical benefit and saves a time. Moreover it is decreasing the understaging effect, assosiated with convectional pathologoanatomical investigaton. In the future, the technical progress will develop the intensive competiton between the sentinel lymph node mapping and the improved imaging diagnostic techniques as flurodeoxyglucose (18FDG), positron emision tomography (PET), or the other molecular imaging techniques. Unfortunately, the limited spatial resolution of these techniques, do not allow to be used for tumor staging as sentinel lymph node techniques. Therefore the sentinel lymphnode mapping become the choice of the lymphnode staging technique.

  13. [Ultrasonography of the prostate gland : From B‑image through multiparametric ultrasound to targeted biopsy].

    PubMed

    Steinkohl, F; Luger, A; Bektic, J; Aigner, F

    2017-08-01

    Prostate cancer is the most frequent cancer in men. The diagnosis is normally achieved by a systematic prostate biopsy; however, this is a randomized approach by which a substantial number of significant carcinomas go undetected. For this reason, in recent years imaging techniques have been continuously developed, which enable visualization and therefore targeted biopsies. The use of systematic biopsies is a standard procedure for the detection of prostate cancer. The quality of biopsies can be increased if the prostate is examined for the presence of suspected cancerous alterations during the biopsy. This can be carried out using multiparametric transrectral ultrasound. Multiparametric ultrasound within the framework of a targeted biopsy increases the detection rate of significant prostate carcinomas with a simultaneous decrease in detection of insignificant carcinomas; however, the diagnostic reliability and the evidence level of multiparametric transrectal ultrasound are not yet sufficiently high to be able to replace a systematic biopsy. In the hands of a well-trained examiner multiparametric transrectal ultrasound represents a good method for detection of prostate carcinomas. With the progression in technical developments of ultrasound technology, the detection rate will presumably be further increased.

  14. Applications and limitations of radiomics

    NASA Astrophysics Data System (ADS)

    Yip, Stephen S. F.; Aerts, Hugo J. W. L.

    2016-07-01

    Radiomics is an emerging field in quantitative imaging that uses advanced imaging features to objectively and quantitatively describe tumour phenotypes. Radiomic features have recently drawn considerable interest due to its potential predictive power for treatment outcomes and cancer genetics, which may have important applications in personalized medicine. In this technical review, we describe applications and challenges of the radiomic field. We will review radiomic application areas and technical issues, as well as proper practices for the designs of radiomic studies.

  15. Structural Imaging and Parkinson's Disease: Moving Toward Quantitative Markers of Disease Progression.

    PubMed

    Sterling, N W; Lewis, M M; Du, G; Huang, X

    2016-05-27

    Parkinson's disease (PD) is a progressive age-related neurodegenerative disorder. Although the pathological hallmark of PD is dopaminergic cell death in the substantia nigra pars compacta, widespread neurodegenerative changes occur throughout the brain as disease progresses. Postmortem studies, for example, have demonstrated the presence of Lewy pathology, apoptosis, and loss of neurotransmitters and interneurons in both cortical and subcortical regions of PD patients. Many in vivo structural imaging studies have attempted to gauge PD-related pathology, particularly in gray matter, with the hope of identifying an imaging biomarker. Reports of brain atrophy in PD, however, have been inconsistent, most likely due to differences in the studied populations (i.e. different disease stages and/or clinical subtypes), experimental designs (i.e. cross-sectional vs. longitudinal), and image analysis methodologies (i.e. automatic vs. manual segmentation). This review attempts to summarize the current state of gray matter structural imaging research in PD in relationship to disease progression, reconciling some of the differences in reported results, and to identify challenges and future avenues.

  16. Transforming Dermatologic Imaging for the Digital Era: Metadata and Standards.

    PubMed

    Caffery, Liam J; Clunie, David; Curiel-Lewandrowski, Clara; Malvehy, Josep; Soyer, H Peter; Halpern, Allan C

    2018-01-17

    Imaging is increasingly being used in dermatology for documentation, diagnosis, and management of cutaneous disease. The lack of standards for dermatologic imaging is an impediment to clinical uptake. Standardization can occur in image acquisition, terminology, interoperability, and metadata. This paper presents the International Skin Imaging Collaboration position on standardization of metadata for dermatologic imaging. Metadata is essential to ensure that dermatologic images are properly managed and interpreted. There are two standards-based approaches to recording and storing metadata in dermatologic imaging. The first uses standard consumer image file formats, and the second is the file format and metadata model developed for the Digital Imaging and Communication in Medicine (DICOM) standard. DICOM would appear to provide an advantage over using consumer image file formats for metadata as it includes all the patient, study, and technical metadata necessary to use images clinically. Whereas, consumer image file formats only include technical metadata and need to be used in conjunction with another actor-for example, an electronic medical record-to supply the patient and study metadata. The use of DICOM may have some ancillary benefits in dermatologic imaging including leveraging DICOM network and workflow services, interoperability of images and metadata, leveraging existing enterprise imaging infrastructure, greater patient safety, and better compliance to legislative requirements for image retention.

  17. Nuclear Technology Division annual progress report for period ending June 30, 1972

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1972-10-01

    This document is a report of progress on technical programs of the Nuclear Technology,Division of Aerojet Nuclear Company for FY 72 ending June 30, 1972. It contains abstracts or expansions of abstracts of papers which have been published within the year. In these cases, preprints or reprints of the articles available. Results of work in progress are also reported; since this work is of a preliminary nature, the authors should be contacted before including any reference to these works in other publications.

  18. Region of interest and windowing-based progressive medical image delivery using JPEG2000

    NASA Astrophysics Data System (ADS)

    Nagaraj, Nithin; Mukhopadhyay, Sudipta; Wheeler, Frederick W.; Avila, Ricardo S.

    2003-05-01

    An important telemedicine application is the perusal of CT scans (digital format) from a central server housed in a healthcare enterprise across a bandwidth constrained network by radiologists situated at remote locations for medical diagnostic purposes. It is generally expected that a viewing station respond to an image request by displaying the image within 1-2 seconds. Owing to limited bandwidth, it may not be possible to deliver the complete image in such a short period of time with traditional techniques. In this paper, we investigate progressive image delivery solutions by using JPEG 2000. An estimate of the time taken in different network bandwidths is performed to compare their relative merits. We further make use of the fact that most medical images are 12-16 bits, but would ultimately be converted to an 8-bit image via windowing for display on the monitor. We propose a windowing progressive RoI technique to exploit this and investigate JPEG 2000 RoI based compression after applying a favorite or a default window setting on the original image. Subsequent requests for different RoIs and window settings would then be processed at the server. For the windowing progressive RoI mode, we report a 50% reduction in transmission time.

  19. Update on Modern Management of Pheochromocytoma and Paraganglioma.

    PubMed

    Lenders, Jacques W M; Eisenhofer, Graeme

    2017-06-01

    Despite all technical progress in modern diagnostic methods and treatment modalities of pheochromocytoma/paraganglioma, early consideration of the presence of these tumors remains the pivotal link towards the best possible outcome for patients. A timely diagnosis and proper treatment can prevent the wide variety of potentially catastrophic cardiovascular complications. Modern biochemical testing should include tests that offer the best available diagnostic performance, measurements of metanephrines and 3-methoxytyramine in plasma or urine. To minimize false-positive test results particular attention should be paid to pre-analytical sampling conditions. In addition to anatomical imaging by computed tomography (CT) or magnetic resonance imaging, new promising functional imaging modalities of photon emission tomography/CT using with somatostatin analogues such as ⁶⁸Ga-DOTATATE (⁶⁸Ga-labeled DOTA(0)-Tyr(3)-octreotide) will probably replace ¹²³I-MIBG (iodine-123-metaiodobenzylguanidine) in the near future. As nearly half of all pheochromocytoma patients harbor a mutation in one of the 14 tumor susceptibility genes, genetic testing and counseling should at least be considered in all patients with a proven tumor. Post-surgical annual follow-up of patients by measurements of plasma or urinary metanephrines should last for at least 10 years for timely detection of recurrent or metastatic disease. Patients with a high risk for recurrence or metastatic disease (paraganglioma, young age, multiple or large tumors, genetic background) should be followed up lifelong. Copyright © 2017 Korean Endocrine Society.

  20. A framework for activity detection in wide-area motion imagery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Porter, Reid B; Ruggiero, Christy E; Morrison, Jack D

    2009-01-01

    Wide-area persistent imaging systems are becoming increasingly cost effective and now large areas of the earth can be imaged at relatively high frame rates (1-2 fps). The efficient exploitation of the large geo-spatial-temporal datasets produced by these systems poses significant technical challenges for image and video analysis and data mining. In recent years there has been significant progress made on stabilization, moving object detection and tracking and automated systems now generate hundreds to thousands of vehicle tracks from raw data, with little human intervention. However, the tracking performance at this scale, is unreliable and average track length is much smallermore » than the average vehicle route. This is a limiting factor for applications which depend heavily on track identity, i.e. tracking vehicles from their points of origin to their final destination. In this paper we propose and investigate a framework for wide-area motion imagery (W AMI) exploitation that minimizes the dependence on track identity. In its current form this framework takes noisy, incomplete moving object detection tracks as input, and produces a small set of activities (e.g. multi-vehicle meetings) as output. The framework can be used to focus and direct human users and additional computation, and suggests a path towards high-level content extraction by learning from the human-in-the-loop.« less

  1. PET/MRI – Technical Review

    PubMed Central

    Muzic, Raymond F.; DiFilippo, Frank P.

    2015-01-01

    PET/MR is a hybrid imaging technology with the potential to combine the molecular and functional information of PET with the soft-tissue contrast of MR. Herein we review the technical features and challenges of putting these different technologies together. We emphasize the conceptual to make the material accessible to a wide audience. We begin by reviewing PET/CT, a more mature multi-modality imaging technology, to provide a basis for comparison to the history of PET/MR development. We discuss the motivation and challenges of PET/MR and different approaches that have been used to meet the challenges. We conclude with a speculation about the future of this exciting imaging method. PMID:25497909

  2. Report on International Spaceborne Imaging Spectroscopy Technical Committee Calibration and Validation Workshop, National Environment Research Council Field Spectroscopy Facility, University of Edinburgh

    NASA Technical Reports Server (NTRS)

    Ong, C,; Mueller, A.; Thome, K.; Bachmann, M.; Czapla-Myers, J.; Holzwarth, S.; Khalsa, S. J.; Maclellan, C.; Malthus, T.; Nightingale, J.; hide

    2016-01-01

    Calibration and validation are fundamental for obtaining quantitative information from Earth Observation (EO) sensor data. Recognising this and the impending launch of at least five sensors in the next five years, the International Spaceborne Imaging Spectroscopy Technical Committee instigated a calibration and validation initiative. A workshop was conducted recently as part of this initiative with the objective of establishing a good practice framework for radiometric and spectral calibration and validation in support of spaceborne imaging spectroscopy missions. This paper presents the outcomes and recommendations for future work arising from the workshop.

  3. 28 CFR 33.12 - Establishment of State Office.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... received from the Bureau of Justice Assistance, including receipt, review, processing, monitoring, progress and financial report review, technical assistance, grant adjustments, accounting, auditing, and fund...

  4. 28 CFR 33.12 - Establishment of State Office.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... received from the Bureau of Justice Assistance, including receipt, review, processing, monitoring, progress and financial report review, technical assistance, grant adjustments, accounting, auditing, and fund...

  5. Follow-up of negative MRI-targeted prostate biopsies: when are we missing cancer?

    PubMed

    Gold, Samuel A; Hale, Graham R; Bloom, Jonathan B; Smith, Clayton P; Rayn, Kareem N; Valera, Vladimir; Wood, Bradford J; Choyke, Peter L; Turkbey, Baris; Pinto, Peter A

    2018-05-21

    Multiparametric magnetic resonance imaging (mpMRI) has improved clinicians' ability to detect clinically significant prostate cancer (csPCa). Combining or fusing these images with the real-time imaging of transrectal ultrasound (TRUS) allows urologists to better sample lesions with a targeted biopsy (Tbx) leading to the detection of greater rates of csPCa and decreased rates of low-risk PCa. In this review, we evaluate the technical aspects of the mpMRI-guided Tbx procedure to identify possible sources of error and provide clinical context to a negative Tbx. A literature search was conducted of possible reasons for false-negative TBx. This includes discussion on false-positive mpMRI findings, termed "PCa mimics," that may incorrectly suggest high likelihood of csPCa as well as errors during Tbx resulting in inexact image fusion or biopsy needle placement. Despite the strong negative predictive value associated with Tbx, concerns of missed disease often remain, especially with MR-visible lesions. This raises questions about what to do next after a negative Tbx result. Potential sources of error can arise from each step in the targeted biopsy process ranging from "PCa mimics" or technical errors during mpMRI acquisition to failure to properly register MRI and TRUS images on a fusion biopsy platform to technical or anatomic limits on needle placement accuracy. A better understanding of these potential pitfalls in the mpMRI-guided Tbx procedure will aid interpretation of a negative Tbx, identify areas for improving technical proficiency, and improve both physician understanding of negative Tbx and patient-management options.

  6. Progressive Vector Quantization on a massively parallel SIMD machine with application to multispectral image data

    NASA Technical Reports Server (NTRS)

    Manohar, Mareboyana; Tilton, James C.

    1994-01-01

    A progressive vector quantization (VQ) compression approach is discussed which decomposes image data into a number of levels using full search VQ. The final level is losslessly compressed, enabling lossless reconstruction. The computational difficulties are addressed by implementation on a massively parallel SIMD machine. We demonstrate progressive VQ on multispectral imagery obtained from the Advanced Very High Resolution Radiometer instrument and other Earth observation image data, and investigate the trade-offs in selecting the number of decomposition levels and codebook training method.

  7. Functional cardiac magnetic resonance microscopy

    NASA Astrophysics Data System (ADS)

    Brau, Anja Christina Sophie

    2003-07-01

    The study of small animal models of human cardiovascular disease is critical to our understanding of the origin, progression, and treatment of this pervasive disease. Complete analysis of disease pathophysiology in these animal models requires measuring structural and functional changes at the level of the whole heart---a task for which an appropriate non-invasive imaging method is needed. The purpose of this work was thus to develop an imaging technique to support in vivo characterization of cardiac structure and function in rat and mouse models of cardiovascular disease. Whereas clinical cardiac magnetic resonance imaging (MRI) provides accurate assessment of the human heart, the extension of cardiac MRI from humans to rodents presents several formidable scaling challenges. Acquiring images of the mouse heart with organ definition and fluidity of contraction comparable to that achieved in humans requires an increase in spatial resolution by a factor of 3000 and an increase in temporal resolution by a factor of ten. No single technical innovation can meet the demanding imaging requirements imposed by the small animal. A functional cardiac magnetic resonance microscopy technique was developed by integrating improvements in physiological control, imaging hardware, biological synchronization of imaging, and pulse sequence design to achieve high-quality images of the murine heart with high spatial and temporal resolution. The specific methods and results from three different sets of imaging experiments are presented: (1) 2D functional imaging in the rat with spatial resolution of 175 mum2 x 1 mm and temporal resolution of 10 ms; (2) 3D functional imaging in the rat with spatial resolution of 100 mum 2 x 500 mum and temporal resolution of 30 ms; and (3) 2D functional imaging in the mouse with spatial resolution down to 100 mum2 x 1 mm and temporal resolution of 10 ms. The cardiac microscopy technique presented here represents a novel collection of technologies capable of acquiring routine high-quality images of murine cardiac structure and function with minimal artifacts and markedly higher spatial resolution compared to conventional techniques. This work is poised to serve a valuable role in the evaluation of cardiovascular disease and should find broad application in studies ranging from basic pathophysiology to drug discovery.

  8. Routine Computer Tomography Imaging for the Detection of Recurrences in High-Risk Melanoma Patients.

    PubMed

    Park, Tristen S; Phan, Giao Q; Yang, James C; Kammula, Udai; Hughes, Marybeth S; Trebska-McGowan, Kasia; Morton, Kathleen E; White, Donald E; Rosenberg, Steven A; Sherry, Richard M

    2017-04-01

    The use of routine CT imaging for surveillance in asymptomatic patients with cutaneous melanoma is controversial. We report our experience using a surveillance strategy that included CT imaging for a cohort of patients with high-risk melanoma. A total of 466 patients with high-risk cutaneous melanoma enrolled in adjuvant immunotherapy trials were followed for tumor progression by physical examination, labs, and CT imaging as defined by protocol. Evaluations were obtained at least every 6 months for year 1, every 6 months for year 2, and then annually for the remainder of the 5-year study. Time to tumor progression, sites of recurrence, and the method of relapse detection were identified. The patient cohort consisted of 115 stage II patients, 328 stage III patients, and 23 patients with resected stage IV melanoma. The medium time to progression for the 225 patients who developed tumor progression was 7 months. Tumor progression was detected by patients, physician examination or routine labs, or by CT imaging alone in 27, 14, and 59% of cases respectively. Melanoma recurrences were noted to be locoregional in 36% of cases and systemic in 64% of cases. Thirty percent of patients with locoregional relapse and 75% of patients with systemic relapse were detected solely by CT imaging. CT imaging alone detected the majority of sites of disease progression in our patients with high-risk cutaneous melanoma. This disease was not heralded by symptoms, physical examination, or blood work. Although the benefit of the early detection of advanced melanoma is unknown, this experience is relevant because of the rapid development and availability of potentially curative immunotherapies.

  9. Internet Color Imaging

    DTIC Science & Technology

    2000-07-01

    UNCLASSIFIED Defense Technical Information Center Compilation Part Notice ADPO1 1348 TITLE: Internet Color Imaging DISTRIBUTION: Approved for public...Paper Internet Color Imaging Hsien-Che Lee Imaging Science and Technology Laboratory Eastman Kodak Company, Rochester, New York 14650-1816 USA...ABSTRACT The sharing and exchange of color images over the Internet pose very challenging problems to color science and technology . Emerging color standards

  10. 41. Photocopy of progress photograph ca. 1974, photographer unknown. Original ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    41. Photocopy of progress photograph ca. 1974, photographer unknown. Original photograph Property of United States Air Force, 21" Space Command. This is the source for views 41 to 47. CAPE COD AIR STATION PAVE PAWS FACILITY - SHOWING BUILDING "RED IRON" STEEL STRUCTURE NEARING COMPLETION. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA

  11. Center for Information Services Fourth Quarterly Progress Report, Phase IIB; Detailed Design and Prototype Development, 1 October 1971 to 31 December 1971.

    ERIC Educational Resources Information Center

    Kehl, W. B.; And Others

    The administrative activity, including organization, staff, budget and external contacts, and the technical progress of IPS development, experimental service, workshops, documentation and related activities of the Center for Information Services (at the University of California, Los Angeles) are reported upon in this document. Pages 9 and 10 may…

  12. Curriculum-Based Measurement: Developing a Computer-Based Assessment Instrument for Monitoring Student Reading Progress on Multiple Indicators

    ERIC Educational Resources Information Center

    Forster, Natalie; Souvignier, Elmar

    2011-01-01

    The purpose of this study was to examine the technical adequacy of a computer-based assessment instrument which is based on hierarchical models of text comprehension for monitoring student reading progress following the Curriculum-Based Measurement (CBM) approach. At intervals of two weeks, 120 third-grade students finished eight CBM tests. To…

  13. Progressive transmission of secured images with authentication using decompositions into monovariate functions

    NASA Astrophysics Data System (ADS)

    Leni, Pierre-Emmanuel; Fougerolle, Yohan D.; Truchetet, Frédéric

    2014-05-01

    We propose a progressive transmission approach of an image authenticated using an overlapping subimage that can be removed to restore the original image. Our approach is different from most visible watermarking approaches that allow one to later remove the watermark, because the mark is not directly introduced in the two-dimensional image space. Instead, it is rather applied to an equivalent monovariate representation of the image. Precisely, the approach is based on our progressive transmission approach that relies on a modified Kolmogorov spline network, and therefore inherits its advantages: resilience to packet losses during transmission and support of heterogeneous display environments. The marked image can be accessed at any intermediate resolution, and a key is needed to remove the mark to fully recover the original image without loss. Moreover, the key can be different for every resolution, and the images can be globally restored in case of packet losses during the transmission. Our contributions lie in the proposition of decomposing a mark (an overlapping image) and an image into monovariate functions following the Kolmogorov superposition theorem; and in the combination of these monovariate functions to provide a removable visible "watermarking" of images with the ability to restore the original image using a key.

  14. Quantitative T2 mapping of recurrent glioblastoma under bevacizumab improves monitoring for non-enhancing tumor progression and predicts overall survival

    PubMed Central

    Hattingen, Elke; Jurcoane, Alina; Daneshvar, Keivan; Pilatus, Ulrich; Mittelbronn, Michel; Steinbach, Joachim P.; Bähr, Oliver

    2013-01-01

    Background Anti-angiogenic treatment in recurrent glioblastoma patients suppresses contrast enhancement and reduces vasogenic edema while non-enhancing tumor progression is common. Thus, the importance of T2-weighted imaging is increasing. We therefore quantified T2 relaxation times, which are the basis for the image contrast on T2-weighted images. Methods Conventional and quantitative MRI procedures were performed on 18 patients with recurrent glioblastoma before treatment with bevacizumab and every 8 weeks thereafter until further tumor progression. We segmented the tumor on conventional MRI into 3 subvolumes: enhancing tumor, non-enhancing tumor, and edema. Using coregistered quantitative maps, we followed changes in T2 relaxation time in each subvolume. Moreover, we generated differential T2 maps by a voxelwise subtraction using the first T2 map under bevacizumab as reference. Results Visually segmented areas of tumor and edema did not differ in T2 relaxation times. Non-enhancing tumor volume did not decrease after commencement of bevacizumab treatment but strikingly increased at progression. Differential T2 maps clearly showed non-enhancing tumor progression in previously normal brain. T2 relaxation times decreased under bevacizumab without re-increasing at tumor progression. A decrease of <26 ms in the enhancing tumor following exposure to bevacizumab was associated with longer overall survival. Conclusions Combining quantitative MRI and tumor segmentation improves monitoring of glioblastoma patients under bevacizumab. The degree of change in T2 relaxation time under bevacizumab may be an early response parameter predictive of overall survival. The sustained decrease in T2 relaxation times toward values of healthy tissue masks progressive tumor on conventional T2-weighted images. Therefore, quantitative T2 relaxation times may detect non-enhancing progression better than conventional T2-weighted imaging. PMID:23925453

  15. Renewal of radiological equipment.

    PubMed

    2014-10-01

    In this century, medical imaging is at the heart of medical practice. Besides providing fast and accurate diagnosis, advances in radiology equipment offer new and previously non-existing options for treatment guidance with quite low morbidity, resulting in the improvement of health outcomes and quality of life for the patients. Although rapid technological development created new medical imaging modalities and methods, the same progress speed resulted in accelerated technical and functional obsolescence of the same medical imaging equipment, consequently creating a need for renewal. Older equipment has a high risk of failures and breakdowns, which might cause delays in diagnosis and treatment of the patient, and safety problems both for the patient and the medical staff. The European Society of Radiology is promoting the use of up-to-date equipment, especially in the context of the EuroSafe Imaging Campaign, as the use of up-to-date equipment will improve quality and safety in medical imaging. Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or renewal. This plan should look forward a minimum of 5 years, with annual updates. Teaching points • Radiological equipment has a definite life cycle span, resulting in unavoidable breakdown and decrease or loss of image quality which renders equipment useless after a certain time period.• Equipment older than 10 years is no longer state-of-the art equipment and replacement is essential. Operating costs of older equipment will be high when compared with new equipment, and sometimes maintenance will be impossible if no spare parts are available.• Older equipment has a high risk of failure and breakdown, causing delays in diagnosis and treatment of the patient and safety problems both for the patient and the medical staff.• Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or replacement. This plan should look forward a minimum of 5 years, with annual updating.

  16. Preliminary technical results review of FY81 experiments. Volume 1: Fiscal year 1981/82 spring small grains pilot experiment. [Canada and the United States

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Technical progress made in the foreign commodity production forecasting for the advancement of spring small grains (SSG) area estimation is reported with emphasis on results achieved since the last AgRISTARS level semiannual review. Major objectives and accomplishments are reviewed and the experiment is described. The technical approach data assessment, and data systems used are considered. Results of the group approach comparison study are presented along with preliminary aggregation results for SSG processing procedures. The outlook for the future is assessed.

  17. Hybrid imaging worldwide-challenges and opportunities for the developing world: a report of a Technical Meeting organized by IAEA.

    PubMed

    Kashyap, Ravi; Dondi, Maurizio; Paez, Diana; Mariani, Guliano

    2013-05-01

    The growth in nuclear medicine, in the past decade, is largely due to hybrid imaging, specifically single-photon emission tomography-computed tomography (SPECT-CT) and positron emission tomography-computed tomography (PET-CT). Introduction and use of hybrid imaging has been growing at a fast pace. This has led to many challenges and opportunities to the personnel dealing with it. The International Atomic Energy Agency (IAEA) keeps a close watch on the trends in applications of nuclear techniques in health by many ways, including obtaining inputs from member states and professional societies. In 2012, a Technical Meeting on trends in hybrid imaging was organized by IAEA to understand the current status and trends of hybrid imaging using nuclear techniques, its role in clinical practice, and associated educational needs and challenges. Perspective of scientific societies and professionals from all the regions of the world was obtained. Heterogeneity in value, educational needs, and access was noted and the drivers of this heterogeneity were discussed. This article presents the key points shared during the technical meeting, focusing primarily on SPECT-CT and PET-CT, and shares the action plan for IAEA to deal with heterogeneity as suggested by the participants. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Is screening with digital imaging using one retinal view adequate?

    PubMed

    Herbert, H M; Jordan, K; Flanagan, D W

    2003-05-01

    To compare the detection of diabetic retinopathy from digital images with slit-lamp biomicroscopy, and to determine whether British Diabetic Association (BDA) screening criteria are attained (>80% sensitivity, >95% specificity, &<5% technical failure). Diabetics referred for screening were studied in a prospective fashion. A single 45 degrees fundus image was obtained using the nonmydriatic digital camera. Each patient subsequently underwent slit-lamp biomicroscopy and diabetic retinopathy grading by a consultant ophthalmologist. Diabetic retinopathy and maculopathy was graded according to the Early Treatment of Diabetic Retinopathy Study. A total of 145 patients (288 eyes) were identified for screening. Of these, 26% of eyes had diabetic retinopathy, and eight eyes (3%) had sight-threatening diabetic retinopathy requiring treatment. The sensitivity for detection of any diabetic retinopathy was 38% and the specificity 95%. There was a 4% technical failure rate. There were 42/288 false negatives and 10/288 false positives. Of the 42 false negatives, 18 represented diabetic maculopathy, 20 represented peripheral diabetic retinopathy and four eyes had both macular and peripheral changes. Three eyes in the false-negative group (1% of total eyes) had sight-threatening retinopathy. There was good concordance between the two consultants (79% agreement on slit-lamp biomicroscopy and 84% on digital image interpretation). The specificity value and technical failure rate compare favourably with BDA guidelines. The low sensitivity for detection of any retinopathy reflects failure to detect minimal maculopathy and retinopathy outside the 45 degrees image. This could be improved by an additional nasal image and careful evaluation of macular images with a low threshold for slit-lamp biomicroscopy if image quality is poor.

  19. New Researches and Application Progress of Commonly Used Optical Molecular Imaging Technology

    PubMed Central

    Chen, Zhi-Yi; Yang, Feng; Lin, Yan; Zhou, Qiu-Lan; Liao, Yang-Ying

    2014-01-01

    Optical molecular imaging, a new medical imaging technique, is developed based on genomics, proteomics and modern optical imaging technique, characterized by non-invasiveness, non-radiativity, high cost-effectiveness, high resolution, high sensitivity and simple operation in comparison with conventional imaging modalities. Currently, it has become one of the most widely used molecular imaging techniques and has been applied in gene expression regulation and activity detection, biological development and cytological detection, drug research and development, pathogenesis research, pharmaceutical effect evaluation and therapeutic effect evaluation, and so forth, This paper will review the latest researches and application progresses of commonly used optical molecular imaging techniques such as bioluminescence imaging and fluorescence molecular imaging. PMID:24696850

  20. JPRS Report, Science & Technology, USSR: Science & Technology Policy.

    DTIC Science & Technology

    1987-07-07

    fully reflect the end results of scientific and technical progress. The formation of the unified fund for the development of science and technology ...209058 JPRS-UST-87-009 7 JULY 1987 /ffifr FOREIGN BROADCAST INFORMATION SERVICE JPRS Repor Science & Technology USSR: Science... Technology Policy 19980715 121 REPRODUCED BY U.S. DEPARTMENTOF COMMERCE NATIONAL TECHNICAL •^ INFORMATIONSERVICE A rf *r*lQ ürjA T Tw» SPRINGFIELD, VA

  1. Advances in optimal routing through computer networks

    NASA Technical Reports Server (NTRS)

    Paz, I. M.

    1977-01-01

    The optimal routing problem is defined. Progress in solving the problem during the previous decade is reviewed, with special emphasis on technical developments made during the last few years. The relationships between the routing, the throughput, and the switching technology used are discussed and their future trends are reviewed. Economic aspects are also briefly considered. Modern technical approaches for handling the routing problems and, more generally, the flow control problems are reviewed.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rhinefrank, Kenneth; Lamb, Bradford; Prudell, Joseph

    This Project aims to satisfy objectives of the DOE’s Water Power Program by completing a system detailed design (SDD) and other important activities in the first phase of a utility-scale grid-connected ocean wave energy demonstration. In early 2012, Columbia Power (CPwr) had determined that further cost and performance optimization was necessary in order to commercialize its StingRAY wave energy converter (WEC). CPwr’s progress toward commercialization, and the requisite technology development path, were focused on transitioning toward a commercial-scale demonstration. This path required significant investment to be successful, and the justification for this investment required improved annual energy production (AEP) andmore » lower capital costs. Engineering solutions were developed to address these technical and cost challenges, incorporated into a proposal to the US Department of Energy (DOE), and then adapted to form the technical content and statement of project objectives of the resulting Project (DE-EE0005930). Through Project cost-sharing and technical collaboration between DOE and CPwr, and technical collaboration with Oregon State University (OSU), National Renewable Energy Lab (NREL) and other Project partners, we have demonstrated experimentally that these conceptual improvements have merit and made significant progress towards a certified WEC system design at a selected and contracted deployment site at the Wave Energy Test Site (WETS) at the Marine Corps Base in Oahu, HI (MCBH).« less

  3. Laparoscopic partial nephrectomy: Technical considerations and an update

    PubMed Central

    Dominguez-Escrig, Jose L; Vasdev, Nikhil; O’Riordon, Anna; Soomro, Naeem

    2011-01-01

    The widespread use of radiological imaging (ultrasound, computed tomography and magnetic resonance imaging) has resulted in a steady increase in the incidental diagnosis of small renal masses. While open partial nephrectomy (OPN) remains the reference standard for the management of small renal masses, laparoscopic partial nephrectomy (LPN) continues to evolve. LPN is currently advocated to be at par with OPN oncologically. The steep learning curve and technical demand of LPN make it challenging to establish this as a new procedure. We present a detailed up-to-date review on the previous, current and planned technical considerations for the use of LPN, highlighting important surgical techniques, including single-port and robotic surgery, techniques on improving intra-operative haemostasis and the management of complications specific to LPN. PMID:22022109

  4. Nuclear medicine and imaging research (quantitative studies in radiopharmaceutical science). Progress report, January 1, 1984-December 31, 1984

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beck, R.N.; Cooper, M.D.

    1984-09-01

    This report presents progress in the areas of cardiac nuclear medicine, other imaging studies, investigations with biomolecules, and assessment of risks associated with the clinical use of radiopharmaceuticals. (ACR)

  5. ATM experiment S-056 image processing requirements definition

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A plan is presented for satisfying the image data processing needs of the S-056 Apollo Telescope Mount experiment. The report is based on information gathered from related technical publications, consultation with numerous image processing experts, and on the experience that was in working on related image processing tasks over a two-year period.

  6. Dual-Energy CT: Basic Principles, Technical Approaches, and Applications in Musculoskeletal Imaging (Part 1).

    PubMed

    Omoumi, Patrick; Becce, Fabio; Racine, Damien; Ott, Julien G; Andreisek, Gustav; Verdun, Francis R

    2015-12-01

    In recent years, technological advances have allowed manufacturers to implement dual-energy computed tomography (DECT) on clinical scanners. With its unique ability to differentiate basis materials by their atomic number, DECT has opened new perspectives in imaging. DECT has been used successfully in musculoskeletal imaging with applications ranging from detection, characterization, and quantification of crystal and iron deposits; to simulation of noncalcium (improving the visualization of bone marrow lesions) or noniodine images. Furthermore, the data acquired with DECT can be postprocessed to generate monoenergetic images of varying kiloelectron volts, providing new methods for image contrast optimization as well as metal artifact reduction. The first part of this article reviews the basic principles and technical aspects of DECT including radiation dose considerations. The second part focuses on applications of DECT to musculoskeletal imaging including gout and other crystal-induced arthropathies, virtual noncalcium images for the study of bone marrow lesions, the study of collagenous structures, applications in computed tomography arthrography, as well as the detection of hemosiderin and metal particles. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  7. Dual-Energy CT: Basic Principles, Technical Approaches, and Applications in Musculoskeletal Imaging (Part 2).

    PubMed

    Omoumi, Patrick; Verdun, Francis R; Guggenberger, Roman; Andreisek, Gustav; Becce, Fabio

    2015-12-01

    In recent years, technological advances have allowed manufacturers to implement dual-energy computed tomography (DECT) on clinical scanners. With its unique ability to differentiate basis materials by their atomic number, DECT has opened new perspectives in imaging. DECT has been successfully used in musculoskeletal imaging with applications ranging from detection, characterization, and quantification of crystal and iron deposits, to simulation of noncalcium (improving the visualization of bone marrow lesions) or noniodine images. Furthermore, the data acquired with DECT can be postprocessed to generate monoenergetic images of varying kiloelectron volts, providing new methods for image contrast optimization as well as metal artifact reduction. The first part of this article reviews the basic principles and technical aspects of DECT including radiation dose considerations. The second part focuses on applications of DECT to musculoskeletal imaging including gout and other crystal-induced arthropathies, virtual noncalcium images for the study of bone marrow lesions, the study of collagenous structures, applications in computed tomography arthrography, as well as the detection of hemosiderin and metal particles. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  8. MR-guided microwave ablation in hepatic tumours: initial results in clinical routine.

    PubMed

    Hoffmann, Rüdiger; Rempp, Hansjörg; Keßler, David-Emanuel; Weiß, Jakob; Pereira, Philippe L; Nikolaou, Konstantin; Clasen, Stephan

    2017-04-01

    Evaluation of the technical success, patient safety and technical effectiveness of magnetic resonance (MR)-guided microwave ablation of hepatic malignancies. Institutional review board approval and informed patient consent were obtained. Fifteen patients (59.8 years ± 9.5) with 18 hepatic malignancies (7 hepatocellular carcinomas, 11 metastases) underwent MR-guided microwave ablation using a 1.5-T MR system. Mean tumour size was 15.4 mm ± 7.7 (7-37 mm). Technical success and ablation zone diameters were assessed by post-ablative MR imaging. Technique effectiveness was assessed after 1 month. Complications were classified according to the Common Terminology Criteria for Adverse Events (CTCAE). Mean follow-up was 5.8 months ± 2.6 (1-10 months). Technical success and technique effectiveness were achieved in all lesions. Lesions were treated using 2.5 ± 1.2 applicator positions. Mean energy and ablation duration per tumour were 37.6 kJ ± 21.7 (9-87 kJ) and 24.7 min ± 11.1 (7-49 min), respectively. Coagulation zone short- and long-axis diameters were 31.5 mm ± 10.5 (16-65 mm) and 52.7 mm ± 15.4 (27-94 mm), respectively. Two CTCAE-2-complications occurred (pneumothorax, pleural effusion). Seven patients developed new tumour manifestations in the untreated liver. Local tumour progression was not observed. Microwave ablation is feasible under near real-time MR guidance and provides effective treatment of hepatic malignancies in one session. • Planning, applicator placement and therapy monitoring are possible without using contrast enhancement • Energy transmission from the generator to the scanner room is safely possible • MR-guided microwave ablation provides effective treatment of hepatic malignancies in one session • Therapy monitoring is possible without applicator retraction from the ablation site.

  9. A multiresolution halftoning algorithm for progressive display

    NASA Astrophysics Data System (ADS)

    Mukherjee, Mithun; Sharma, Gaurav

    2005-01-01

    We describe and implement an algorithmic framework for memory efficient, 'on-the-fly' halftoning in a progressive transmission environment. Instead of a conventional approach which repeatedly recalls the continuous tone image from memory and subsequently halftones it for display, the proposed method achieves significant memory efficiency by storing only the halftoned image and updating it in response to additional information received through progressive transmission. Thus the method requires only a single frame-buffer of bits for storage of the displayed binary image and no additional storage is required for the contone data. The additional image data received through progressive transmission is accommodated through in-place updates of the buffer. The method is thus particularly advantageous for high resolution bi-level displays where it can result in significant savings in memory. The proposed framework is implemented using a suitable multi-resolution, multi-level modification of error diffusion that is motivated by the presence of a single binary frame-buffer. Aggregates of individual display bits constitute the multiple output levels at a given resolution. This creates a natural progression of increasing resolution with decreasing bit-depth.

  10. History and future technical innovation in positron emission tomography

    PubMed Central

    Jones, Terry; Townsend, David

    2017-01-01

    Abstract. Instrumentation for positron emission tomography (PET) imaging has experienced tremendous improvements in performance over the past 60 years since it was first conceived as a medical imaging modality. Spatial resolution has improved by a factor of 10 and sensitivity by a factor of 40 from the early designs in the 1970s to the high-performance scanners of today. Multimodality configurations have emerged that combine PET with computed tomography (CT) and, more recently, with MR. Whole-body scans for clinical purposes can now be acquired in under 10 min on a state-of-the-art PET/CT. This paper will review the history of these technical developments over 40 years and summarize the important clinical research and healthcare applications that have been made possible by these technical advances. Some perspectives for the future of this technology will also be presented that promise to bring about new applications of this imaging modality in clinical research and healthcare. PMID:28401173

  11. A Review of Significant Advances in Neutron Imaging from Conception to the Present

    NASA Astrophysics Data System (ADS)

    Brenizer, J. S.

    This review summarizes the history of neutron imaging with a focus on the significant events and technical advancements in neutron imaging methods, from the first radiograph to more recent imaging methods. A timeline is presented to illustrate the key accomplishments that advanced the neutron imaging technique. Only three years after the discovery of the neutron by English physicist James Chadwick in 1932, neutron imaging began with the work of Hartmut Kallmann and Ernst Kuhn in Berlin, Germany, from 1935-1944. Kallmann and Kuhn were awarded a joint US Patent issued in January 1940. Little progress was made until the mid-1950's when Thewlis utilized a neutron beam from the BEPO reactor at Harwell, marking the beginning of the application of neutron imaging to practical applications. As the film method was improved, imaging moved from a qualitative to a quantitative technique, with applications in industry and in nuclear fuels. Standards were developed to aid in the quantification of the neutron images and the facility's capabilities. The introduction of dynamic neutron imaging (initially called real-time neutron radiography and neutron television) in the late 1970's opened the door to new opportunities and new challenges. As the electronic imaging matured, the introduction of the CCD imaging devices and solid-state light intensifiers helped address some of these challenges. Development of improved imaging devices for the medical community has had a major impact on neutron imaging. Additionally, amorphous silicon sensors provided improvements in temporal resolution, while providing a reasonably large imaging area. The development of new neutron imaging sensors and the development of new neutron imaging techniques in the past decade has advanced the technique's ability to provide insight and understanding of problems that other non-destructive techniques could not provide. This rapid increase in capability and application would not have been possible without the advances in computer processing speed and increased memory storage. For example, images with enhanced contrast are created by using the reflection, refraction, diffraction and ultra small angle scattering interactions. It is somewhat ironic that, like the first development of neutron images, the technique remains limited by the availability of high-intensity neutron sources, both in the facility cost and portability.

  12. 40 CFR 57.605 - Consent.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... such agency determines are needed to evaluate the technical or economic merits of the program; (c... discussions of progress, interpretation of data and results, and any other similar purposes as deemed...

  13. 78 FR 14361 - Proposal Review; Notice of Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-05

    ... awards. The review and evaluation may also include assessment of the progress of awarded proposals. The... confidential nature, including technical information; financial data, such as salaries; and personal...

  14. 78 FR 54686 - Proposal Review; Notice of Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-05

    ... awards. The review and evaluation may also include assessment of the progress of awarded proposals. The... confidential nature, including technical information; financial data, such as salaries; and personal...

  15. Personal Background Interview of Jim McBarron

    NASA Technical Reports Server (NTRS)

    McBarron, Jim; Wright, Rebecca

    2012-01-01

    Jim McBarron exhibits a wealth of knowledge gathered from more than 40 years of experience with NASA, EVA, and spacesuits. His biography, progression of work at NASA, impact on EVA and the U.S. spacesuit, and career accomplishments are of interest to many. Wright, from the JSC History Office, conducted a personal background interview with McBarron. This interview highlighted the influences and decision-making methods that impacted McBarron's technical and management contributions to the space program. Attendees gained insight on the external and internal NASA influences on career progression within the EVA and spacesuit, and the type of accomplishments and technical advances that committed individuals can make. He concluded the presentation with a question and answer period that included a brief discussion about close calls and Russian spacesuits.

  16. Moses Lake Fishery Restoration Project; Factors Affecting the Recreational Fishery in Moses Lake Washington, Annual Report 2002-2003.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burgess, Dave

    2003-11-01

    This annual report is a precursor to the final technical report we will be writing the next contract period. Consequently, this report, covering the period between September 27, 2002, and September 26, 2003, represents a progress report towards the final technical report we anticipate completing by September 26, 2004. Sample analysis and field work have progressed well and we anticipate no further delays. There are 4 objectives: (1) To quantify secondary production Moses Lake; (2) To quantify the influence of predation on target fishes in Moses Lake; (3) To quantify mortality of selected fished in Moses Lake; and (4) Tomore » assess effects of habitat changes from shoreline development and carp on the fish community in Moses Lake.« less

  17. Progressive multiple sclerosis: from pathogenic mechanisms to treatment.

    PubMed

    Correale, Jorge; Gaitán, María I; Ysrraelit, María C; Fiol, Marcela P

    2017-03-01

    During the past decades, better understanding of relapsing-remitting multiple sclerosis disease mechanisms have led to the development of several disease-modifying therapies, reducing relapse rates and severity, through immune system modulation or suppression. In contrast, current therapeutic options for progressive multiple sclerosis remain comparatively disappointing and challenging. One possible explanation is a lack of understanding of pathogenic mechanisms driving progressive multiple sclerosis. Furthermore, diagnosis is usually retrospective, based on history of gradual neurological worsening with or without occasional relapses, minor remissions or plateaus. In addition, imaging methods as well as biomarkers are not well established. Magnetic resonance imaging studies in progressive multiple sclerosis show decreased blood-brain barrier permeability, probably reflecting compartmentalization of inflammation behind a relatively intact blood-brain barrier. Interestingly, a spectrum of inflammatory cell types infiltrates the leptomeninges during subpial cortical demyelination. Indeed, recent magnetic resonance imaging studies show leptomeningeal contrast enhancement in subjects with progressive multiple sclerosis, possibly representing an in vivo marker of inflammation associated to subpial demyelination. Treatments for progressive disease depend on underlying mechanisms causing central nervous system damage. Immunity sheltered behind an intact blood-brain barrier, energy failure, and membrane channel dysfunction may be key processes in progressive disease. Interfering with these mechanisms may provide neuroprotection and prevent disability progression, while potentially restoring activity and conduction along damaged axons by repairing myelin. Although most previous clinical trials in progressive multiple sclerosis have yielded disappointing results, important lessons have been learnt, improving the design of novel ones. This review discusses mechanisms involved in progressive multiple sclerosis, correlations between histopathology and magnetic resonance imaging studies, along with possible new therapeutic approaches. © The Author (2016). Published by Oxford University Press on behalf of the Guarantors of Brain. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Features and limitations of mobile tablet devices for viewing radiological images.

    PubMed

    Grunert, J H

    2015-03-01

    Mobile radiological image display systems are becoming increasingly common, necessitating a comparison of the features of these systems, specifically the operating system employed, connection to stationary PACS, data security and rang of image display and image analysis functions. In the fall of 2013, a total of 17 PACS suppliers were surveyed regarding the technical features of 18 mobile radiological image display systems using a standardized questionnaire. The study also examined to what extent the technical specifications of the mobile image display systems satisfy the provisions of the Germany Medical Devices Act as well as the provisions of the German X-ray ordinance (RöV). There are clear differences in terms of how the mobile systems connected to the stationary PACS. Web-based solutions allow the mobile image display systems to function independently of their operating systems. The examined systems differed very little in terms of image display and image analysis functions. Mobile image display systems complement stationary PACS and can be used to view images. The impacts of the new quality assurance guidelines (QS-RL) as well as the upcoming new standard DIN 6868 - 157 on the acceptance testing of mobile image display units for the purpose of image evaluation are discussed. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Microvascular distribution in the ocular conjunctiva and digestive tract in an experimental setting.

    PubMed

    Pranskūnas, Andrius; Pilvinis, Vidas; Dambrauskas, Žilvinas; Rasimavičiūtė, Renata; Milieškaitė, Eglė; Bubulis, Algimantas; Veikutis, Vincentas; Vaitkaitis, Dinas; Boerma, E Christiaan

    2012-01-01

    Recently improved microcirculatory imaging techniques, such as orthogonal polarization spectral (OPS) and its technical successor sidestream dark field (SDF) imaging, in handheld devices have allowed a direct observation of the microcirculation at the bedside. Usually a cut-off of 20 µm in diameter is used to differentiate small vessels (mainly capillaries) from large vessels (mainly venules) during this technique. We hypothesized that it was possible to measure the small vessels with a considerably smaller inner diameter. Images of the sublingual, conjunctival, jejunal, and rectal mucosa microcirculation were obtained with SDF videomicroscopy (Microscan®, Microvision Medical, Amsterdam, the Netherlands). Using the validated software, the length and diameter of microvessels were manually traced with a computer-generated line. All vessels were divided into the groups according to the inner diameter. A total of 156 SDF images of the sublingual, ocular conjunctival, jejunal, and rectal mucosa were taken in 13 pigs. The length of microscopic vessels progressively increased with a decrease in the vessel diameter less than 8 mm in all the lodges, such as sublingual (80.6% of total vessel length), ocular conjunctival (76.5% of total vessel length), jejunal (99.8% of total vessel length), and rectal (97.8% of total vessel length), due to capillary network formation. There was no significant difference in the distribution of vessels from 0 to 10 µm in diameter comparing sublingual and eye conjunctival as well as jejunal and rectal mucosa. In pigs, small-diameter microscopic vessels (<10 µm) dominated in all the studied lodges (sublingual, ocular conjunctival, jejunal, and rectal mucosa), and this is evidence to establish a new cut-off for capillaries in microcirculatory analysis of SDF imaging in experimental and clinical studies.

  20. Metal plasmon-coupled fluorescence imaging and label free coenzyme detection in cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Jian, E-mail: jian@cfs.bioment.umaryland.edu; Fu, Yi; Li, Ge

    2012-08-31

    Highlights: Black-Right-Pointing-Pointer Metal nanoparticle for fluorescence cell imaging. Black-Right-Pointing-Pointer Non-invasive emission detection of coenzyme in cell on time-resolved confocal microscope. Black-Right-Pointing-Pointer Near-field interaction of flavin adenine dinucleotide with silver substrate. Black-Right-Pointing-Pointer Isolation of emissions by coenzymes from cellular autofluorescence on fluorescence cell imaging. -- Abstract: Flavin adenine dinucleotide (FAD) is a key metabolite in cellular energy conversion. Flavin can also bind with some enzymes in the metabolic pathway and the binding sites may be changed due to the disease progression. Thus, there is interest on studying its expression level, distribution, and redox state within the cells. FAD is naturally fluorescent,more » but it has a modest extinction coefficient and quantum yield. Hence the intrinsic emission from FAD is generally too weak to be isolated distinctly from the cellular backgrounds in fluorescence cell imaging. In this article, the metal nanostructures on the glass coverslips were used as substrates to measure FAD in cells. Particulate silver films were fabricated with an optical resonance near the absorption and the emission wavelengths of FAD which can lead to efficient coupling interactions. As a result, the emission intensity and quantum yield by FAD were greatly increased and the lifetime was dramatically shortened resulting in less interference from the longer lived cellular background. This feature may overcome the technical limits that hinder the direct observation of intrinsically fluorescent coenzymes in the cells by fluorescence microscopy. Fluorescence cell imaging on the metallic particle substrates may provide a non-invasive strategy for collecting the information of coenzymes in cells.« less

Top