Immediate loading of subcrestally placed dental implants in anterior and premolar sites.
Henningsen, Anders; Smeets, Ralf; Köppen, Kai; Sehner, Susanne; Kornmann, Frank; Gröbe, Alexander; Heiland, Max; Gerlach, Till
2017-11-01
Immediate loading of dental implants has been evolving into an appropriate procedure for the treatment of partially edentulous jaws. The purpose of this study was to evaluate the clinical success and radiological outcome of immediately and delayed loaded dental implants in anterior and premolar sites. In this retrospective study, data of 163 individuals requiring tooth removal with subsequent implant placement in anterior and premolar sites were analyzed. Implants were immediately loaded by provisional acrylic resin bridges or loaded with delay. Implants were followed up annually for up to 9 years including intraoral radiographs. A total of 285 implants in 163 patients were placed. 218 implants were immediately loaded and 67 implants with delay. Fifteen implants failed during the follow-up period resulting in survival rates of 94.5% for immediate loading and 95.5% for delayed loading. After an initial decrease of 0.3 mm in the first 12 months the marginal bone level remained stable. No statistically significant differences were found in marginal bone loss between immediately and delayed loaded implants (P = 0.518, 95% CI). Within the limits of this study, immediate loading of immediately subcrestally placed dental implants in anterior and premolar sites is a reliable treatment option for dental rehabilitation. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Effect of healing time on bone-implant contact of orthodontic micro-implants: a histologic study.
Ramazanzadeh, Barat Ali; Fatemi, Kazem; Dehghani, Mahboobe; Mohtasham, Nooshin; Jahanbin, Arezoo; Sadeghian, Hamed
2014-01-01
Objectives. This study aimed to evaluate the effect of immediate and delayed loading of orthodontic micro-implants on bone-implant contact. Materials and Methods. Sixty four micro-implants were implanted in dog's jaw bone. The micro-implants were divided into loaded and unloaded (control) groups. The control group had two subgroups: four and eight weeks being implanted. The loaded group had two subgroups of immediate loading and delayed (after four weeks healing) loading. Loaded samples were subjected to 200g load for four weeks. After sacrificing the animals micro-implants and surrounding tissues were observed histologically. Bone-implant contact ratios (BIC) were calculated and different groups' results were compared by three-way ANOVA. Results. Mean survival rate was 96.7% in general. Survival rates were 96.7%, 94.4% and 100% for control, immediate and delayed loaded groups, respectively. BIC values were not significantly different in loaded and control groups, immediate and delayed loading groups, and pressure and tension sides. Mandibular micro-implants had significantly higher BIC than maxillary ones in immediate loading, 4-weeks control, and 8-weeks control groups (P = 0.021, P = 0.009, P = 0.003, resp.). Conclusion Immediate or delayed loading of micro-implants in dog did not cause significant difference in Bone-implant contact which could be concluded that healing time had not significant effect on micro-implant stability.
Effect of Healing Time on Bone-Implant Contact of Orthodontic Micro-Implants: A Histologic Study
Ramazanzadeh, Barat Ali; Fatemi, Kazem; Dehghani, Mahboobe; Mohtasham, Nooshin; Jahanbin, Arezoo; Sadeghian, Hamed
2014-01-01
Objectives. This study aimed to evaluate the effect of immediate and delayed loading of orthodontic micro-implants on bone-implant contact. Materials and Methods. Sixty four micro-implants were implanted in dog's jaw bone. The micro-implants were divided into loaded and unloaded (control) groups. The control group had two subgroups: four and eight weeks being implanted. The loaded group had two subgroups of immediate loading and delayed (after four weeks healing) loading. Loaded samples were subjected to 200g load for four weeks. After sacrificing the animals micro-implants and surrounding tissues were observed histologically. Bone-implant contact ratios (BIC) were calculated and different groups' results were compared by three-way ANOVA. Results. Mean survival rate was 96.7% in general. Survival rates were 96.7%, 94.4% and 100% for control, immediate and delayed loaded groups, respectively. BIC values were not significantly different in loaded and control groups, immediate and delayed loading groups, and pressure and tension sides. Mandibular micro-implants had significantly higher BIC than maxillary ones in immediate loading, 4-weeks control, and 8-weeks control groups (P = 0.021, P = 0.009, P = 0.003, resp.). Conclusion Immediate or delayed loading of micro-implants in dog did not cause significant difference in Bone-implant contact which could be concluded that healing time had not significant effect on micro-implant stability. PMID:25006463
Zygogiannis, Kostas; Aartman, Irene Ha; Parsa, Azin; Tahmaseb, Ali; Wismeijer, Daniel
The aim of this 1-year randomized trial was to evaluate and compare the clinical and radiographic performance of four immediately loaded mini dental implants (MDIs) and two immediately loaded standard-sized tissue-level (STL) implants, placed in the interforaminal region of the mandible and used to retain mandibular overdentures (IODs) in completely edentulous patients. A total of 50 completely edentulous patients wearing conventional maxillary dentures and complaining about insufficient retention of their mandibular dentures were divided into two groups; 25 patients received four MDIs and 25 patients received two STL implants. The marginal bone loss (MBL) at the mesial and distal sides of each implant was assessed by means of standardized intraoral radiographs after a period of 1 year. Implant success and survival rates were also calculated. Immediate loading was possible for all patients in the first group. In the second group, an immediate loading protocol could not be applied for 10 patients. These patients were treated with a delayed loading protocol. A mean MBL of 0.42 ± 0.56 mm for the MDIs and 0.54 ± 0.49 mm for the immediately loaded STL implants was recorded at the end of the evaluation period. There was no statistically significant difference between the MDIs and the immediately loaded STL implants. Two MDIs failed, resulting in a survival rate of 98%. The success rate was 91%. For the immediately loaded conventional implants, the survival rate was 100% and the success rate 96.7% after 1 year of function. However, in 10 patients, the immediate loading protocol could not be followed. Considering the limitations of this short-term clinical study, immediate loading of four unsplinted MDIs or two splinted STL implants to retain mandibular overdentures seems to be a feasible treatment option. The marginal bone level changes around the MDIs were well within the clinically acceptable range.
Influence of immediate loading on provisional restoration in dental implant stability
NASA Astrophysics Data System (ADS)
Ikbal, M.; Odang, R. W.; Indrasari, M.; Dewi, R. S.
2017-08-01
The success of dental implant treatment is determined by the primary stability at placement. One factor that could influence this stability is occlusal loading through provisional restoration. Two types of loading protocols are usually used: immediate and delayed loading. However, some controversies remain about the influence of occlusal loading on implant stability. Therefore, the influence of immediate loading on implant stability must be studied. An animal study was conducted by placing nine dental implants in the mandibular jaw of three Macaca fascicularis. Provisional restorations with various occlusal contacts (no, light, and normal contact) were placed on the implant. The implant stability was measured using the Ostell ISQ three times: immediately (baseline) and at the first and second months after implant placement. The implant stability between implants with no and normal occlusal contact as well as light and normal occlusal contact showed significant differences (p < 0.05) at the first and second months after implant placement. However, no significant increase (p > 0.05) in implant stability was seen at the baseline and the first and second months after implant placement for all occlusal contact groups. Immediate loading influenced the implant stability, and provisional restoration of implant without occlusal contact showed the highest implant stability.
Romanos, Georgios E
2014-01-01
There are benefits to be derived from the use of advanced surgical protocols in conjunction with immediate functional loading using various dental implant designs and implant-abutment connections. Clinical protocols with simultaneous bone grafting, immediate implant placement, and/or sinus augmentations when a shortened treatment period is needed are included in this report, with the aim of providing understanding of the main protocol characteristics and prerequisites for long-term success in implant dentistry. This article presents three clinical cases that illustrate possibilities for advanced immediate loading using different implant designs. It demonstrates treatment of severe bone defects and the facilitation of placing implants in regenerated bone that can be immediately loaded.
Akca, Kivanc; Eser, Atilim; Eckert, Steven; Cavusoglu, Yeliz; Cehreli, Murat Cavit
2013-01-01
To compare biomechanical outcomes of immediately and conventionally loaded bar-retained implant-supported maxillary overdentures using finite element stress analysis. Finite element models were created to replicate the spatial positioning of four 4.1 × 12-mm implants in the completely edentulous maxillae of four cadavers to support bar-retained overdentures with 7-mm distal extension cantilevers. To simulate the bone-implant interface of immediately loaded implants, a contact situation was defined at the interface; conventional loading was simulated by "bonding" the implants to the surrounding bone. The prostheses were loaded with 100 N in the projected molar regions bilaterally, and strain magnitudes were measured at the buccal aspect of bone. The amplitude of axial and lateral strains, the overall strain magnitudes, and the strain magnitudes around anterior and posterior implants in the immediate loading group were comparable to those seen in the conventional loading group, suggesting that the loading regimens created similar stress/strain fields (P > .05). Conventional and immediate loading of maxillary implants supporting bar-retained overdentures resulted in similar bone strains.
Peñarrocha-Oltra, David; Serra-Pastor, Blanca; Balaguer-Martí, José-Carlos; Peñarrocha-Diago, Miguel; Agustín-Panadero, Rubén
2017-12-01
Immediate loading protocols for the rehabilitation of edentulous or partially edentulous patients have become very popular, due to the conveniences they afford in comparison with conventional loading techniques. A preliminary study was carried out with 8 patients subjected to dental implant treatment with an immediate loading protocol involving a novel system of abutments with flexible screws. Implant survival was analyzed, together with marginal bone loss and patient and dentist satisfaction. A total of 35 implants were subjected to immediate loading using the abutments with flexible screws. The mean patient and dentist satisfaction score was 9.1 and 8.5, respectively. After 12 months the dental implant survival rate was 95.8%, with a mean marginal bone loss of 0.51 ± 0.12 mm. The novel system of abutments with flexible screws offers a good alternative to conventional immediate loading, since it allows rapid and simple manufacture of a reliable passive fit, fixed interim prosthesis after surgery. Key words: Dental implants, Flexafit®, Immediate loading, Immediate prosthesis.
Chidagam, Prudhvi Raj Lakshmi Venkata; Gande, Vijaya Chandra; Yadlapalli, Sravanthi; Venkata, Ramani Yarlagadda; Kondaka, Sudheer; Chedalawada, Sravya
2017-04-01
Emergence of dental implants made the replacement of missing tooth easy. During the early days of introduction, implants were loaded three to six months after implant insertion, but understanding of healing cascade and improved production technology has changed the phase of restoration from delayed to immediate loading. To evaluate and compare the clinical outcome of immediate and delayed loaded implant supported prosthesis for missing mandibular first molar. The objectives were bleeding on probing, probing depth, implant mobility, marginal bone level and peri-implant radiolucency were evaluated during follow up period. Twenty patients were included in this study who were in the need of fixed implant supported prosthesis for missing mandibular first molar. Single tooth implant with immediate loading done within two days of implant insertion in one group and another group were loaded after three months of implant insertion. These groups were evaluated clinically and radiographically over a period of 72 months after loading using Wilcoxon matched pairs test and Mann-Whitney U test. The study consists of 14 male and six female patients with the age range of 19 to 31 years. There was no bleeding on probing and probing depth remained well within the normal range even after 72 months of loading among both the groups. Minimal marginal bone loss observed with no mobility and peri-implant radiolucency. Implant supported prosthesis for missing mandibular first molar with immediate loading can be used as a successful treatment modality. It reduces treatment time, provides early function and prevents undue migration of adjacent tooth. Immediate loading showed similar clinical and radiographic results as that of delayed loading, indicating it as an equally efficient technique for implant supported prosthesis.
Immediate loading of titanium hexed screw-type implants in the edentulous patient: case report.
Calvo, M P; Muller, E; Garg, A K
2000-01-01
Histologic and histomorphometric studies in both animals and humans have shown that more rapid and greater bone-to-implant contact can be achieved with implants that incorporate certain surface characteristics compared with the original machined-surface implants. Such findings are significant because various implant designs may allow the fixtures to sufficiently resist functional loading sooner than originally thought. The case report presented here indicates that immediate loading of hexed titanium screw-type implants in the anterior mandible can lead to successful osseointegration and clinical outcome. The number of implants placed, their distribution, and the type of rigid connection are critical considerations for immediate loading. A bone height that can accommodate dental implants > or = 10 mm long is recommended. Biomechanically, the implants to be immediately loaded must be stable and resistant to macromovement to ensure good osseointegration.
Stokholm, Rie; Isidor, Flemming; Nyengaard, Jens R
2014-11-01
The primary aim of this study was to compare the bone reaction around immediate-loaded non-splinted single implants vs. delayed loaded non-splinted single implants placed in healed ridges in the posterior mandible. Six adult Macaca Fascicularis monkeys were used in this study. The first and second premolars and the first molar were extracted in both sides of the mandible. After 3 months of healing, four implants (Replace Select Tapered; Nobel Biocare, Gothenburg, Sweden) with a moderately rough surface (TiUnite, Nobel Biocare) were placed in the edentulous areas of each monkey, two in each side. The implants had a length of 10 mm and a diameter of 3.5 mm. Four groups of varying time and occlusal loading aspects were created: (i) control group: implant placed non-loaded for 3 months; (ii) immediate loaded: implant placed and loaded immediately for 3 months; (iii) immediate loaded: implant placed and loaded immediately for 6 months; and (iv) delayed loaded: implant placed submerged for 3 months and then loaded for 3 months. At the loaded implants, after a second stage surgery, a composite crown was made directly on an abutment mounted on the implant reinsuring simultaneous occlusal contact on the implant crown and the neighboring teeth. After euthanization of the animals, histologic specimens were quantified in the light microscope. All implants were clinically, radiographically, and histologically osseointegrated at the time of euthanization and with only mild signs of inflammation in the peri-implant mucosa. The histologic marginal bone level was located on average 1.14-1.74 mm apical to the margin of the implants in the various groups. The average bone-to-implant contact (BIC) varied between 55% and 65% and the average bone density (i.e., the proportion of mineralized bone tissue from the implant surface and to a distance of 1 mm lateral to the implant) varied between 30.6% and 34.2%. No statistical significant differences between groups were observed in the above-stated histomorphometric parameters. Similar histologic and histomorphometric findings were observed in immediately and delayed loaded non-splinted implants placed in the posterior mandible of macaque monkeys. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Prasant, M C; Thukral, Rishi; Kumar, Sachin; Sadrani, Sannishth M; Baxi, Harsh; Shah, Aditi
2016-10-01
Ever since its introduction in 1977, a minimum of few months of period is required for osseointegration to take place after dental implant surgery. With the passage of time and advancements in the fields of dental implant, this healing period is getting smaller and smaller. Immediate loading of dental implants is becoming a very popular procedure in the recent time. Hence, we retrospectively analyzed the various risk factors for the failure of delayed and immediate loaded dental implants. In the present study, retrospective analysis of all the patients was done who underwent dental implant surgeries either by immediate loading procedure or by delayed loading procedures. All the patients were divided broadly into two groups with one group containing patients in which delayed loaded dental implants were placed while other consisted of patients in whom immediate loaded dental implants were placed. All the patients in whom follow-up records were missing and who had past medical history of any systemic diseases were excluded from the present study. Evaluation of associated possible risk factors was done by classifying the predictable factors as primary and secondary factors. All the results were analyzed by Statistical Package for the Social Sciences (SPSS) software. Kaplan-Meier survival analyses and chi-square test were used for assessment of level of significance. In delayed and immediate group of dental implants, mean age of the patients was 54.2 and 54.8 years respectively. Statistically significant results were obtained while comparing the clinical parameters of the dental implants in both the groups while demographic parameters showed nonsignificant correlation. Significant higher risk of dental implant failure is associated with immediate loaded dental implants. Tobacco smoking, shorter implant size, and other risk factors play a significant role in predicting the success and failure of dental implants. Delayed loaded dental implant placement should be preferred as they are associated with decreased risk of implant failure.
Cannizzaro, Gioacchino; Leone, Michele; Esposito, Marco
2008-01-01
To evaluate the efficacy of immediate loading versus early loading at 6 weeks of bar-retained mandibular overdentures supported by two implants placed with a flapless technique. Sixty patients were randomised: 30 to the immediately loaded group and 30 to the early loaded group. To be immediately loaded, implants had to be inserted with a minimum torque > 48 Ncm. Outcome measures were prosthesis and implant failures, biological and biomechanical complications, patient satisfaction, and Implant Stability Quotient (ISQ) assessed with a resonance frequency analysis instrument. Sixty implants were placed in each group. Flaps had to be raised in nine patients to check drill direction or to better visualise the area after multiple teeth extraction. Two implants in two patients did not reach the planned insertion torque and were immediately replaced by larger diameters ones. After 1 year no drop out occurred and two early loaded implants failed in two patients. There were no statistically significant differences between groups for prosthesis failures, implant losses, complications, and mean ISQ values; however, patients in the immediately loaded group were significantly more satisfied than those loaded early. When comparing mean ISQ values taken 6 weeks after placement with 1-year data within each group, values decreased significantly. Mandibular overdentures can be successfully loaded the same day of implant placement with a minimally invasive surgery, increasing patient satisfaction while decreasing treatment time and patient discomfort. No apparent advantages were seen when loading the overdentures at 6 weeks.
Cannizzaro, Gioacchino; Felice, Pietro; Loi, Ignazio; Viola, Paolo; Ferri, Vittorio; Leone, Michele; Lazzarini, Matteo; Trullenque-Eriksson, Anna; Esposito, Marco
To compare the outcome of immediately loaded single implants with a machined or a roughened surface. Fifty patients had two implant sites randomly allocated to receive flaplessplaced single Syra implants (Sweden & Martina), one with a machined and one with a roughened surface (sand-blasted with zirconia powder and acid etched), according to a split-mouth design. To be loaded immediately, implants had to be inserted with a torque superior to 50 Ncm. Implants were restored with definitive crowns in direct occlusal contact within 48 h. Patients were followed for 6 months after loading. Outcome measures were prosthetic and implant failures and complications. Two machined implants and four roughened implants were not loaded immediately. Six months after loading no dropout occurred. One implant loaded late, which had a rough implant surface, failed 20 days after loading (P (McNemar test) = 0.625; difference in proportions = -0.04; 95% CI: -0.15 to 0.07). Three crowns had to be remade on machined implants and four on roughened implants (P (McNemar test) = 1.000; difference in proportions = -0.02; 95% CI: -0.12 to 0.08). Three machined and five roughened implants experienced complications (P (McNemar test) = 0.625; difference in proportions = -0.04; 95% CI: -0.15 to 0.07). There were no statistically significant differences between groups for crown and implant losses as well as complications. Up to 6 months after loading both machined and roughened flapless-placed and immediately loaded single implants provided good and similar results, however, longer follow-ups are needed to evaluate the long-term prognosis of implants with different surfaces.
Peñarrocha-Oltra, David; Serra-Pastor, Blanca; Balaguer-Martí, José-Carlos; Agustín-Panadero, Rubén
2017-01-01
Background Immediate loading protocols for the rehabilitation of edentulous or partially edentulous patients have become very popular, due to the conveniences they afford in comparison with conventional loading techniques. Material and Methods A preliminary study was carried out with 8 patients subjected to dental implant treatment with an immediate loading protocol involving a novel system of abutments with flexible screws. Implant survival was analyzed, together with marginal bone loss and patient and dentist satisfaction. Results A total of 35 implants were subjected to immediate loading using the abutments with flexible screws. The mean patient and dentist satisfaction score was 9.1 and 8.5, respectively. After 12 months the dental implant survival rate was 95.8%, with a mean marginal bone loss of 0.51 ± 0.12 mm. Conclusions The novel system of abutments with flexible screws offers a good alternative to conventional immediate loading, since it allows rapid and simple manufacture of a reliable passive fit, fixed interim prosthesis after surgery. Key words:Dental implants, Flexafit®, Immediate loading, Immediate prosthesis. PMID:29410752
Kopp, Sigmar; Behrend, Detlef; Kundt, Günther; Ottl, Peter; Frerich, Bernhard; Warkentin, Mareike
2013-06-01
To examine the influence of bone-substitute application during implantation on the success of immediately placed and loaded dental implants. A total of 147 consecutive patients (age, 16.5-80.4 years) were provided with 696 immediately loaded implants. The mean follow-up time was 34.1 months. Of these implants, 50.4% (n=351) were immediately placed into extraction sockets. A total of 119 implants were added by simultaneous bone-substitute application (NanoBone, Artoss GmbH, Rostock Germany), whereas the other implants were placed in healed bone. Univariate and multivariate analysis was performed using IBM SPSS V.20. The overall implant success rate was 96.1%. Implants with simultaneous bone replacement had a hazard ratio of 0.877 (p=0.837); 95% CI, 0.253-3.04). Factors found to be statistically significant modifiers of success on multivariate analysis (p<0.05) included type of superstructure (p<0.001), implant-abutment connection (p<0.001), membrane use (p=0.010), and jaw (p=0.026). None of the other factors investigated were significant modifiers. The present study demonstrates high success rates for immediately loaded implants and their superstructures independent of the simultaneous application of bone substitute. The declared aim of socket preservation, the prevention avoiding bone loss, is achieved in the immediate implant placement scenario under immediate-loading conditions.
Neugarten, Jay; Tuminelli, Frank J; Walter, Leora
To report on the outcome of placement of two bilateral zygomatic implants with an immediately loaded prosthesis. A retrospective chart review was conducted of all patients treated with zygomatic implants between August 1, 2011 and June 6, 2016. All patients had at least two zygomatic implants placed bilaterally and immediately loaded with a provisional prosthesis the same day of implant placement. The implants were Nobel Biocare TiUnite or machined surface with lengths of 30 to 52.5 mm. All patients were treated by a team consisting of one surgeon, a restorative dentist or prosthodontist, an anesthesiologist, and a laboratory technician. Implant success was defined as successful integration of the implant; prosthetic success was defined as retention of the prosthesis under normal function. One hundred five zygomatic implants were placed and immediately loaded in 28 patients over a period of 1 to 60 months. Ages ranged from 46 to 81 years, with 26 female and 2 male patients. All the implants were placed by one surgeon. The immediate load on the day of implant placement was completed by either one of 2 prosthodontists or 11 restorative dentists. Implant success was 96% (101/105). All four failed implants were in one patient and were TiUnite surface coated. This study demonstrated that two zygomatic implants bilaterally placed and immediately loaded with a full-arch splinted prosthesis will provide a predictable outcome.
He, Yun; Hasan, Istabrak; Keilig, Ludger; Fischer, Dominik; Ziegler, Luisa; Abboud, Marcus; Wahl, Gerhard; Bourauel, Christoph
2018-03-01
This study combines finite element method and animal studies, aiming to investigate tissue remodelling processes around dental implants inserted into sika deer antler and to develop an alternative animal consuming model for studying bone remodelling around implants. Implants were inserted in the antlers and loaded immediately via a self-developed loading device. After 3, 4, 5 and 6 weeks, implants and surrounding tissue were taken out. Specimens were scanned by μCT scanner and finite element models were generated. Immediate loading and osseointegration conditions were simulated at the implant-tissue interface. A vertical force of 10 N was applied on the implant. During the healing time, density and Young's modulus of antler tissue around the implant increased significantly. For each time point, the values of displacement, stresses and strains in the osseointegration model were lower than those of the immediate loading model. As the healing time increased, the displacement of implants was reduced. The 3-week immediate loading model (9878 ± 1965 μstrain) illustrated the highest strains in the antler tissue. Antler tissue showed similar biomechanical properties as human bone in investigating the bone remodelling around implants, therefore the use of sika deer antler model is a promising alternative in implant biomechanical studies.
Immediate loading with fixed full-arch prostheses in the maxilla: Review of the literature
Peñarrocha-Oltra, David; Covani, Ugo; Peñarrocha-Diago, Miguel
2014-01-01
Objectives: To critically review the evidence-based literature on immediate loading of implants with fixed full-arch prostheses in the maxilla to determine 1) currently recommended performance criteria and 2) the outcomes that can be expected with this procedure. Study Desing: Studies from 2001 to 2011 on immediate loading with fixed full-arch maxillary prostheses were reviewed. Clinical series with at least 5 patients and 12 months of follow-up were included. Case reports, studies with missing data and repeatedly published studies were excluded. In each study the following was assessed: type of study, implant type, number of patients, number of implants, number of implants per patient, use of post-extraction implants, minimum implant length and diameter, type of prosthesis, time until loading, implant survival rate, prosthesis survival rate, marginal bone loss, complications andmean follow-up time. Criteria for patient selection, implant primary stability and bone regeneration were also studied. Results: Thirteen studies were included, reporting a total of 2484 immediately loaded implants in 365 patients. Currently accepted performance criteria regarding patient and implant selection, and surgical and prosthetic procedures were deduced from the reviewed articles. Implant survival rates went from 87.5% to 100%, prosthesis survival rates from 93.8% to 100% and radiographic marginal bone loss from 0.8 mm to 1.6 mm.No intraoperative complications and only minor prosthetic complications were reported. Conclusions: The literature on immediate loading with fixed full-arch prostheses in the maxilla shows that a successful outcome can be expected if adequate criteria are used to evaluate the patient, choose the implant and perform the surgical and prosthetic treatment. Lack of homogeneity within studies limits the relevance of the conclusions that can be drawn, and more controlled randomized studies are necessary to enable comparison between the immediate and the conventional loading procedures. Key words:Immediate loading, full-arch, dental implants, loading protocols. PMID:24880445
Primo, Bruno Tochetto; Mezzari, Leonardo Marcos; da Fontoura Frasca, Luís Carlos; Linderman, Raquel; Rivaldo, Elken Gomes
To evaluate and compare the clinical and radiographic outcomes of mandibular rehabilitation with fixed prostheses on three implants with immediate versus delayed loading. The sample comprised 21 patients who underwent treatment with immediate loading and 23 who received delayed loading. All had worn their prostheses for at least 18 months. Radiographic evaluation of bone loss was carried out in Adobe Photoshop CS5 by a single calibrated examiner using digitized panoramic radiographs. Clinical examination of the technical conditions of the prosthetic device assessed the condition of the acrylic resin base, dental occlusion, metal framework, presence of cover screws, screw fixation of the prosthesis and abutments, length of cantilever (effort) and resistance arms, presence of plaque on prosthetic abutments, and hygiene of the prosthesis. One implant failed in each group, resulting in a 95.23% treatment success rate with immediate loading and 95.65% with delayed loading (no statistically significant between-group difference). In the immediate-loading group, the mean bone loss was 1.96 ± 0.73 mm around central implants and 1.64 ± 0.84 mm at distal implants. In the delayed-loading group, the mean bone loss was 1.85 ± 0.67 mm around central implants and 1.70 ± 0.77 mm at distal implants. According to Student t test, there was no significant within-group difference in bone loss and no difference between the immediate-loading and delayed-loading groups. The only prosthesis-related complications that differed significantly between groups were "condition of the acrylic base," "occlusion," and "presence of right cover screw." There was no statistically significant association of lever arm ratio with peri-implant bone loss or bone loss on the mesial surfaces compared to the distal surfaces of the distal implants. The three-implant-supported fixed prosthesis protocol tested in this study proved to be a viable therapeutic strategy for mandibular edentulous patients with maxillary complete dentures, regardless of whether loading was immediate or delayed, with no difference in peri-implant bone loss.
Mundt, T; Passia, N; Att, W; Heydecke, G; Freitag-Wolf, S; Luthardt, R G; Kappel, S; Konstantinidis, I K; Stiesch, M; Wolfart, S; Kern, M
2017-03-01
This randomized clinical trial compares immediate and delayed loading of single implants to support mandibular overdentures. The aim of this preliminary analysis is to test the hypothesis whether patients with immediate loading will experience less pain and discomfort through the intervention than patients with delayed loading. Edentulous patients in nine German dental schools received a midline implant with a length of 11 mm. Implants with a minimum insertion torque of 30 Ncm and an implant stability quotient of ≥60 were randomly allocated to group A for immediate loading using ball attachments or to group B for delayed loading after 3 months. Patients completed questionnaires with 100-mm visual analogue scales about the items pain, pain during chewing, swelling, bleeding, and perception of the intervention at the day of surgery and 1, 2, 3, and 7 days, thereafter. Groups were compared by Wilcoxon-Mann-Whitney tests (P ≤ 0.05). The questionnaires of 81 patients in group A and 74 patients in group B were completed. The medians for pain and discomfort were moderate (<30). Participants of group A felt significantly more pain from the first day and more swelling from the third day after implantation than participants of group B. The individual perception of interventions showed no significant differences between groups. Immediate loading evoked more postoperative pain and swelling than the two stages of delayed loading. Immediate loading of a single mandibular midline implant supporting overdentures should be carefully considered.
Peter, Burghard
Immediate loading has proven to be a predictable modality for restorations with titanium dental implants. An increasing number of articles indicate that zirconia implants might osseointegrate to a similar extent in this context. This 5-year case report describes an outpatient maxillary restoration with eight immediately loaded zirconia implants. Implantation followed extensive bone augmentation. At the 5-year follow-up, all implants were still well osseointegrated clinically and radiologically. No major bone loss or peri-implantitis had occurred in spite of temporary insufficient patient compliance. More research and studies are needed to confirm these results.
Altinci, Pinar; Can, Gulsen; Gunes, Onur; Ozturk, Caner; Eren, Hakan
2016-12-01
Immediately-loaded, narrow-diameter implants can be a less invasive alternative for the implant-supported fixed rehabilitation of narrow, posterior crests. To determine the stability and marginal bone level (MBL) changes of narrow-diameter, titanium-zirconium (TiZr) implants placed with flapless surgery and loaded immediately in the posterior region. Thirty-eight TiZr implants (3.3 mm diameter, 10 mm length, Roxolid, Straumann AG) were placed in the posterior crests of 14 patients with computer-guided flapless surgery as a support of 3-unit posterior bridges. Eighteen implants were loaded immediately, and 20 implants were loaded conventionally. The implant stability quotients were determined at the 1, 2, 4, and 8. weeks of healing before conventional loading, and at the 3, 6, and 12. months after loading by resonance frequency analysis. The MBL changes were measured by digital radiography. The surgical protocols were accomplished without any biological complications. There was no significant difference in the stability changes of TiZr implants between the loading groups (p > .05). The MBL changes were -0.18 ± 0.27 mm and -0.24 ± 0.27 mm at the 12. month of immediate and conventional loading, respectively, which was not statistically significant (p > .05). The stability and MBL changes of TiZr implants supporting posterior 3-unit bridges were clinically acceptable at the first year of loading. © 2016 Wiley Periodicals, Inc.
Merli, Mauro; Moscatelli, Marco; Mariotti, Giorgia; Piemontese, Matteo; Nieri, Michele
2012-02-01
To compare immediate versus early non-occlusal loading of dental implants placed flapless in a 3-year, parallel group, randomized clinical trial. The study was conducted in a private dental clinic between July 2005 and July 2010. Patients 18 years or older were randomized to receive implants for fixed partial dentures in cases of partial edentulism. The test group was represented by immediate non-occlusal implant loading, whereas the control group was represented by early non-occlusal implant loading. The outcome variables were implant failure, complications and radiographic bone level at implant sites 3 years after loading, measured from the implant-abutment junction to the most coronal point of bone-to-implant contact. Randomization was computer-generated with allocation concealment by opaque sequentially numbered sealed envelopes, and the measurer was blinded to group assignment. Sixty patients were randomized: 30 to the immediately loaded group and 30 to the early loaded group. Four patients dropped out; however, the data of all patients were included in the analysis. No implant failure occurred. Two complications occurred in the control group and one in the test group. The mean bone level at 3 years was 1.91 mm for test group and 1.59 mm for control group. The adjusted difference in bone level was 0.26 mm (CI 95% -0.08 to 0.59, p = 0.1232). The null hypothesis of no difference in failure rates, complications and bone level between implants that were loaded immediately or early at 3 years cannot be rejected in this randomized clinical trial. © 2011 John Wiley & Sons A/S.
Instant loading with intraoral welding technique and PRAMA implants: a new prosthetic approach.
Celletti, R; Fanali, S; Laici, C U; Santori, C; Pignatelli, P; Sinjari, B
2017-01-01
When splinting multiple implants passive fit of the framework should be achieved to avoid excessive force distribution on the implants. Recently, a protocol was suggested for immediate loading of multiple implants by welding a titanium bar to implant abutments directly in the oral cavity so as to create a customized, precise and passive metal-reinforced provisional restoration. The intraoral welding technique subsequently proves to be a successful option in the full-arch immediate restorations of the mandible and maxilla. The aim of this article is to present a case report in which a new prosthetic approach, using trans-mucosal implants, is described. Dental implants are instantly loaded with a provisional prosthesis supported by an intraoral welded titanium framework to obtain a precise passive fit of the immediate loaded prosthesis.
Immediate Loading of Tapered Implants Placed in Postextraction Sockets and Healed Sites.
Han, Chang-Hun; Mangano, Francesco; Mortellaro, Carmen; Park, Kwang-Bum
2016-07-01
The aim of the present study was to compare the survival, stability, and complications of immediately loaded implants placed in postextraction sockets and healed sites. Over a 2-year period, all patients presenting with partial or complete edentulism of the maxilla and/or mandible (healed site group, at least 4 months of healing after tooth extraction) or in need of replacement of nonrecoverable failing teeth (postextraction group) were considered for inclusion in this study. Tapered implants featuring a nanostructured calcium-incorporated surface were placed and loaded immediately. The prosthetic restorations comprised single crowns, fixed partial dentures, and fixed full arches. Primary outcomes were implant survival, stability, and complications. Implant stability was assessed at placement and at each follow-up evaluation (1 week, 3 months, and 1 year after placement): implants with an insertion torque (IT) <45 N·cm and/or with an implant stability quotient (ISQ) <70 were considered failed for immediate loading. A statistical analysis was performed. Thirty implants were placed in postextraction sockets of 17 patients, and 32 implants were placed in healed sites of 22 patients. There were no statistically significant differences in ISQ values between the 2 groups, at each assessment. In total, 60 implants (96.8%) had an IT ≥45 and an ISQ ≥70 at placement and at each follow-up control: all these implants were successfully loaded. Only 2 implants (1 in a postextraction socket and 1 in a healed site, 3.2%) could not achieve an IT ≥45 N·cm and/or an ISQ ≥70 at placement or over time: accordingly, these were considered failed for stability, as they could not be subjected to immediate loading. One of these 2 implants, in a healed site of a posterior maxilla, had to be removed, yielding an overall 1-year implant survival rate of 98.4%. No complications were reported. No significant differences were reported between the 2 groups with respect to implant failures and complications. Immediately loaded implants placed in postextraction sockets and healed sites had similar high survival and stability, with no reported complications. Further long-term studies on larger samples of patients are needed to confirm these results.
Redesign of a fixture mount to be used as an impression coping and a provisional abutment as well
Chang, Glenn Hsuan-Chen; Tian, Chen; Hung, Yuen-Siang
2011-01-01
Purpose: An integrated fixture mount/impression coping/ temporary abutment can provide many advantages for immediate loading of dental implants, such as simpler procedure, less chair time, cost reduction, and comfort for the patients. Materials and Methods: A newly designed dental implant fixture mount (DIFMA) can be used as an impression coping for taking an immediate impression. An immediate load provisional prosthesis can then be fabricated shortly after implant placement to immediately load the implants. This fixture mount can also serve as a temporary abutment for immediate chair-side fabrication of provisional prosthesis. Two clinical cases are presented. Results: A clinical case utilizing the fixture mount abutment (DIFMA)/implant assembly is presented. The precision of fitting between the impression copings and implants is secured with this system. The chair time for taking an immediate impression is greatly reduced. Less cost for the restoration is provided and patient comfort is delivered. Conclusions: More patient satisfaction can be conferred by employing the fixture mount in the process of immediate impression taking and as an immediate provisional abutment. PMID:22090763
Šćepanović, Miodrag; Todorović, Aleksandar; Marković, Aleksa; Patrnogić, Vesna; Miličić, Biljana; Moufti, Adel M; Mišić, Tijana
2015-05-01
This 1-year cohort study investigated stability and peri-implant marginal bone level of immediately loaded mini dental implants used to retain overdentures. Each of 30 edentulous patients received 4 mini dental implants (1.8 mm × 13 mm) in the interforaminal mandibular region. The implants were immediately loaded with pre-made overdentures. Outcome measures included implant stability and bone resorption. Implant stability was measured using the Periotest Classic(®) device immediately after placement and on the 3rd and 6th weeks and the 4th, 6th and 12th months postoperatively. The peri-implant marginal bone level (PIBL) was evaluated at the implant's mesial and distal sides from the polished platform to the marginal crest. Radiographs were taken using a tailored film holder to reproducibly position the X-ray tube at the 6th week, 4th and 12th months postoperatively. The primary stability (Periotest value, PTV) measured -0.27 ± 3.41 on a scale of -8 to + 50 (lower PTV reflects higher stability). The secondary stability decreased significantly until week 6 (mean PTV = 7.61 ± 7.05) then increased significantly reaching (PTV = 6.17 ± 6.15) at 12 months. The mean PIBL measured -0.40 mm after 1 year of functional loading, with no statistically significant differences at the various follow-ups (p = 0.218). Mini dental implants placed into the interforaminal region could achieve a favorable primary stability for immediate loading. The follow-up Periotest values fluctuated, apparently reflecting the dynamics of bone remodeling, with the implants remaining clinically stable (98.3%) after 1 year of function. The 1-year bone resorption around immediately loaded MDIs is within the clinically acceptable range for standard implants. Copyright © 2014 Elsevier GmbH. All rights reserved.
Ibañez, Juan C; Tahhan, Marcelo J; Zamar, Juan A; Menendez, Alicia B; Juaneda, Agustina M; Zamar, Nicolas J; Monqaut, Jose L
2005-11-01
The high success rate of dental implants has changed the quality of life for many patients. Immediate loading finds its application in some clinical cases and certainly adds another modality of treatment for the implant patient. Starting with a few implants immediately loaded with a bar overdenture in the mandible, the concept of immediate loading evolved to loading multiple implants in both the maxilla and mandible. In this investigation, 41 consecutive patients who needed full-arch restorations were treated with 343 double acid-etched surface implants between May 1998 and March 2004. The sample included smokers and bruxers. Twenty-three mandibular and 26 maxillary cases were treated, loading the implants within 48 hours, by using resin provisional prostheses, metal-reinforced provisional prostheses, or definitive prostheses (metal-acrylic or metal-ceramic). All implants were followed for 12 to 74 months. Follow-up consisted of clinical as well as radiographic examination. Furthermore, resonance frequency analysis was done in most of the implants during the last 2 years. The success rate obtained was 99.42% (only two mandibular implants that are still surviving were considered failures). The bone level was measured every year. The average radiographic bone level change was 0.56 mm at 12, 0.76 mm at 24, 0.84 mm at 36, 0.82 mm at 48, 0.83 mm at 60, and 0.94 mm at 72 months. A high success rate can be achieved when double acid-etched surface implants are immediately loaded with fixed full-arch restorations in the maxilla and mandible.
Huang, Yan; Van Dessel, Jeroen; Liang, Xin; Depypere, Maarten; Zhong, Weijian; Ma, Guowu; Lambrichts, Ivo; Maes, Frederik; Jacobs, Reinhilde
2014-12-01
To develop a method for characterizing trabecular bone microarchitecture using cone beam computed tomography (CBCT) and to evaluate trabecular bone changes after rehabilitation using immediate versus delayed implant protocols. Six mongrel dogs randomly received 27 titanium implants in the maxillary incisor or mandibular premolar areas, following one of four protocols: (1) normal extraction socket healing; (2) immediate implant placement and immediate loading; (3) delayed implant placement and delayed loading; (4) delayed implant placement and immediate loading. The animals were euthanized at 8 weeks, and block biopsies were scanned using high resolution CBCT. Standard bone structural variables were assessed in coronal, middle, and apical levels. Coronal and middle regions had more compact, more platelike, and thicker trabeculae. Protocols (2), (3), and (4) had significantly higher values (p < 0.001) than protocol (1) for bone surface density, bone surface volume ratio, and connectivity density, while significantly lower values (p < 0.001) were found for trabecular separation and fractal dimension. However, protocols (2), (3), and (4) did not show significantly different bone remodeling. Compared with normal extraction healing, the implant protocols have an improved bone structural integration. Results do not suggest a different bone remodeling pattern when a delayed versus an immediate implant protocol is used. © 2013 Wiley Periodicals, Inc.
Kong, Liang; Gu, Zexu; Li, Tao; Wu, Junjie; Hu, Kaijin; Liu, Yanpu; Zhou, Hongzhi; Liu, Baolin
2009-01-01
A nonlinear finite element method was applied to examine the effects of implant diameter and length on the maximum von Mises stresses in the jaw, and to evaluate the maximum displacement of the implant-abutment complex in immediate-loading models. The implant diameter (D) ranged from 3.0 to 5.0 mm and implant length (L) ranged from 6.0 to 16.0 mm. The results showed that the maximum von Mises stress in cortical bone was decreased by 65.8% under a buccolingual load with an increase in D. In cancellous bone, it was decreased by 71.5% under an axial load with an increase in L. The maximum displacement in the implant-abutment complex decreased by 64.8% under a buccolingual load with an increase in D. The implant was found to be more sensitive to L than to D under axial loads, while D played a more important role in enhancing its stability under buccolingual loads. When D exceeded 4.0 mm and L exceeded 11.0 mm, both minimum stress and displacement were obtained. Therefore, these dimensions were the optimal biomechanical selections for immediate-loading implants in type B/2 bone.
Wojtovicz, Eduardo; España-Lopez, Antonio; Jimenez-Guerra, Alvaro; Monsalve-Guil, Loreto; Ortiz-Garcia, Ivan; Serrera-Figallo, Maria-Angeles
2018-01-01
Background The aim of this prospective study was to report the outcome of treatment with implants inserted after tooth extraction and immediately loaded. Material and Methods Fifty-six patients with single tooth loss were treated with 116 IPX Galimplant® implants with internal connections and a sandblasted, acid-etched surface. All implants were placed after tooth extraction using a flapless approach without bone regeneration, and they were then immediately loaded with cemented acrylic prostheses. After a period of three months, definitive cemented ceramic prostheses were placed. Patients were examined throughout a total of 4 years of follow-up. Marginal bone loss and survival rates were evaluated using digital periapical radiographs, taking into account clinical variables such as age, gender, smoking, history of periodontitis, etiology of extraction, placement site, diameter, and implant length. The Mann-Whitney U and Kruskal-Wallis non-parametric tests were used to compare differences between subgroups created based on the different clinical variables identified. Results Clinical results indicate an implant survival and success rate of 97.4%. Three implants were lost. Of the 116 immediate acrylic single crowns initially placed, 113 were replaced with definitive ceramic crowns after 3 months. A total of 77.8% of implants were inserted in the maxilla, while 22.2% were inserted in the mandible. No further complications were reported after the follow-up period (4 years). The mean marginal bone loss was 0.67 mm ± 0.40 mm. No differences were found among the subgroups of study patients. Conclusions This study indicates that dental implants that are inserted after tooth extraction and immediately loaded may constitute a successful and predictable alternative implant treatment. Key words:Dental implants, post-extraction implants, fresh sockets, immediate loading, immediate prostheses, implant dentistry. PMID:29476669
Omura, Yuri; Kanazawa, Manabu; Sato, Daisuke; Kasugai, Shohei; Minakuchi, Shunsuke
2016-07-01
The aim of this preliminary study is to compare patient-reported outcomes between immediately and conventionally loaded mandibular two-implant overdentures retained by magnetic attachments. Nineteen participants with edentulous mandibles were randomly assigned into either an immediate loading group (immediate group) or a conventional loading group (conventional group). Each participant received 2 implants in the inter-foraminal region by means of flapless surgery. Prostheses in the immediate and conventional groups were loaded using magnetic attachments on the same day as implant placement or 3 months after surgery, respectively. All participants completed questionnaires (the Japanese version of the Oral Health Impact Profile for edentulous [OHIP-EDENT-J], the patient's denture assessment [PDA], and general satisfaction) before implant placement (baseline) and 1, 2, 3, 4, 5, 6, and 12 months after surgery. The median differences between baseline and each monthly score were compared using the Mann-Whitney U test. The differences in median and 95% confidence interval between two groups were analyzed. The immediate group showed slightly lower OHIP-EDENT-J summary score at 1 and 3 months than the conventional group (P=0.09). In the lower denture domain of PDA, the immediate group showed a statistically higher score at 3 months (P=0.04). There was no statistically significant difference in general satisfaction between the two groups. Based on this preliminary study, immediate loading of mandibular two-implant overdentures with magnetic attachments tends to improve oral health-related quality of life and patient assessment earlier than observed with a conventional loading protocol. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Acocella, Alessandro; Ercoli, Carlo; Geminiani, Alessandro; Feng, Changyong; Billi, Mauro; Acocella, Gabriele; Giannini, Domenico; Sacco, Roberto
2012-05-01
Immediate occlusal loading of dental implants in the edentulous mandible has proven to be an effective, reliable, and predictable treatment protocol. However, there is limited long-term data available in the literature, when an electroeroded definitive cast-titanium fixed prosthesis is used for this treatment protocol. The aim of this study was to evaluate the clinical effectiveness of dental implants (Astra Tech Dental, Mölndal, Sweden) in the edentulous mandible immediately loaded with an electroeroded cast-titanium screw-retained fixed prosthesis. Forty-five patients received five implants each in the interforaminal area. All the implants were inserted with torque up to 40 Ncm and the distal implants were distally tilted approximately 20 to 30 degrees to minimize the length of posterior cantilevers. Implants were loaded within 48 hours of placement with an acrylic resin-titanium screw-retained prosthesis fabricated by electroerosion. Two of the 225 inserted implants failed after 3 and 16 months of healing, respectively, with a cumulative survival rate of 99.1% and a prosthetic survival rate of 97.8%. Immediate loading of tilted dental implants inserted in the edentulous mandible with a screw-retained titanium definitive prosthesis fabricated with electrical discharge machining provide reliable and predictable results. © 2011 Wiley Periodicals, Inc.
Berberi, Antoine N; Tehini, Georges E; Noujeim, Ziad F; Khairallah, Alexandre A; Abousehlib, Moustafa N; Salameh, Ziad A
2014-10-01
Delayed placement of implant abutments has been associated with peri-implant marginal bone loss; however, long-term results obtained by modifying surgical and prosthetic techniques after implant placement are still lacking. This study aimed to evaluate the marginal bone loss around titanium implants placed in fresh extraction sockets using two loading protocols after a 5-year follow-up period. A total of 36 patients received 40 titanium implants (Astra Tech) intended for single-tooth replacement. Implants were immediately placed into fresh extraction sockets using either a one-stage (immediate loading by placing an interim prosthesis into functional occlusion) or a two-stage prosthetic loading protocol (insertion of abutments after 8 weeks of healing time). Marginal bone levels relative to the implant reference point were evaluated at four time intervals using intraoral radiographs: at time of implant placement, and 1, 3, and 5 years after implant placement. Measurements were obtained from mesial and distal surfaces of each implant (α = 0.05). One-stage immediate implant placement into fresh extraction sockets resulted in a significant reduction in marginal bone loss (p < 0.002) compared to the traditional two-stage technique. Whereas mesial surfaces remained stable for the 5-year observation period, significant marginal bone loss was observed on distal surfaces of implants after cementation of interim prostheses (p < 0.007) and after 12 months (p < 0.034). Within the limitations of this study, immediate loading of implants placed into fresh extraction sockets reduced marginal bone loss and did not compromise the success rate of the restorations. © 2014 by the American College of Prosthodontists.
Romanos, Georgios E
2009-06-01
Immediate loading of oral implants has been extensively described in the international literature and the requirements for long-term success are evaluated. The author presents here the critical aspects of the criteria for success as well as describes the characteristics of an implant macro- and microdesign for immediate loading to control the periimplant crestal bone loss and secure the long-term stability. Information from the literature and the clinical experience will be presented.
Success and High Predictability of Intraorally Welded Titanium Bar in the Immediate Loading Implants
Fogli, Vaniel; Camerini, Michele; Carinci, Francesco
2014-01-01
The implants failure may be caused by micromotion and stress exerted on implants during the phase of bone healing. This concept is especially true in case of implants placed in atrophic ridges. So the primary stabilization and fixation of implants are an important goal that can also allow immediate loading and oral rehabilitation on the same day of surgery. This goal may be achieved thanks to the technique of welding titanium bars on implant abutments. In fact, the procedure can be performed directly in the mouth eliminating possibility of errors or distortions due to impression. This paper describes a case report and the most recent data about long-term success and high predictability of intraorally welded titanium bar in immediate loading implants. PMID:24963419
Mangano, Francesco G; Caprioglio, Alberto; Levrini, Luca; Farronato, Davide; Zecca, Piero A; Mangano, Carlo
2015-02-01
Only a few studies have dealt with immediately loaded, unsplinted mini-implants supporting ball attachment-retained mandibular overdentures (ODs). The aim of this study is to evaluate treatment outcomes of ball attachment-retained mandibular ODs supported by one-piece, unsplinted, immediately loaded, direct metal laser sintering (DMLS) mini-implants. Over a 4-year period (2009 to 2012), all patients referred to the Dental Clinic, University of Varese, and to a private practice for treatment with mandibular ODs were considered for inclusion in this study. Each patient received three or four DMLS mini-implants. Immediately after implant placement, a mandibular OD was connected to the implants. At each annual follow-up session, clinical and radiographic parameters were assessed, including the following outcome measures: 1) implant failures; 2) peri-implant marginal bone loss; and 3) complications. Statistical analysis was conducted using a life-table analysis. A total of 231 one-piece DMLS mini-implants were inserted in 62 patients. After 4 years of loading, six implants failed, giving an overall cumulative survival rate of 96.9%. The mean distance between the implant shoulder and the first visible bone-to-implant contact was 0.38 ± 0.25 and 0.62 ± 0.20 mm at the 1- and 4-year follow-up examinations, respectively. An incidence of 6.0% of biologic complications was reported; prosthetic complications were more frequent (12.9%). Within the limits of this study, it can be concluded that the immediate loading of one-piece, unsplinted, DMLS titanium mini-implants by means of ball attachment-supported mandibular ODs is a successful treatment procedure. Long-term follow-up studies are needed to confirm these results.
Wentaschek, Stefan; Scheller, Herbert; Schmidtmann, Irene; Hartmann, Sinsa; Weyhrauch, Michael; Weibrich, Gernot; Lehmann, Karl Martin
2015-10-01
To assess the suitability of dental implants for immediate loading, primary stability is usually evaluated intraoperatively. This retrospective study aimed to assess the suitability of three stability parameters - namely, insertion torque (IT), implant stability quotient (ISQ; measured by resonance frequency analysis), and Periotest (PT) values - as potential predictors for the risk of nonosseointegration of immediately loaded splinted implants. The stability parameters were routinely collected under immediate loading. Nineteen patients with 11 edentulous and 8 partially edentulous maxillae were treated with 105 dental implants, which were immediately loaded using temporary fixed dentures. The IT results, PT values, and ISQ results were recorded. Receiver operating characteristic analysis was performed to assess the quality of each parameter as a diagnostic test. After a 3-month observation period, 11 implants in four patients were not osseointegrated. The IT and ISQ (IT 25.0 ± 12.5 Ncm and 8.4 ± 2.3 Ncm; PT -1.5 ± 3.0 and +2.7 ± 3.0; and ISQ 62.6 ± 6.7 and 54.7 ± 6.2) differed significantly between the osseointegrated and failed implants (p < .005). The IT showed the greatest specificity at a sensitivity of 1 and the greatest area under the curve (AUC; 0.929), followed by the PT value (AUC = 0.836) and ISQ (AUC = 0.811). Among the intraoperative parameters analyzed, IT showed the highest specificity at a high sensitivity of 1. Therefore, the IT can be considered the most valid prognostic factor for osseointegration of immediately loaded splinted dental implants. © 2014 Wiley Periodicals, Inc.
Clinical evaluation of immediate loading of titanium orthodontic implants
Chopra, S.S.; Chakranarayan, A.
2015-01-01
Background Skeletal anchorage using dental implants, miniplates, miniscrews and microscrews provides an absolute anchorage for tooth movement. Miniscrew and microscrew implants have many benefits such as ease of placement and removal and immediate orthodontic force application. Methods Fifteen subjects in the permanent dentition with an overjet ≥6 mm received treatment with the 0.018-inch pre-adjusted edgewise appliance system (Roth prescription) and extraction of all first premolars. Titanium orthodontic implants were placed in both the upper quadrants and were immediately loaded with elastic chain from the implant head to the sectional arch wire. Result The overall success rate of immediate loaded titanium orthodontic micro implants (OMI) in the present study was 83.33%, with a mean chairside time of 15.33 min of placing two implants in each patient. Peri-implant inflammation was the only complication observed. Most failures were in the initial part of the study. There was no significant difference in the success rate of implants based on sex, side of placement (right or left) and type of malocclusion. Conclusion The OMIs used in the present study proved to be effective and well tolerated in producing immediate orthodontic anchorage for the retraction. PMID:25859080
Immediate functional loading of single implants: a multicenter study with 4 years of follow-up
Raes, Filiep; Eccellente, Tammaro; Lenzi, Carolina; Ortolani, Michele; Luongo, Giuseppe; Mangano, Carlo; Mangano, Francesco
2018-01-01
Background. In the current scientific literature there are only few studies on the immediate functional loading of single implants. The aim of the present present study was to evaluate the 4-year survival rate, complication rate and peri-implant marginal bone loss (PIMBL) of immediately loaded single implants inserted in healed ridges and fresh post-extraction sites. Methods. Six centers were involved in this prospective study. The surgical and prosthetic protocol was defined in detail, before the start of recruiting patients. Recruitment of patients and performance of surgeries took place between February 2012 and February 2013. Criteria for inclusion were single-tooth gaps in healed ridges and fresh post-extraction sockets. All the fixtures (Anyridge®, Megagen Corporation, Gyeongbuk, South Korea) were functionally loaded immediately after insertion and followed for a period of 4 years. Outcome measures were implant survival, complications and PIMBL. Results. Forty-six patients (18‒73 years of age) were selected. In total, 57 fixtures were placed (10 in fresh post-extraction sockets). After 4 years of functional loading, only one fixture was lost; therefore, high survival rates (97.6% patient-based; 98.1% implant-based) were reported. In addition, a limited incidence of biologic (4.8% patient-based; 3.8% implant-based) and prosthetic (9.7% patient-based; 7.6% implant-based) complications was reported. The overall 4-year PIMBL amounted to 0.38±0.21 mm (healed ridges: 0.4±0.21 mm; fresh post-extraction sockets: 0.33±0.20 mm). Conclusion. Loading single implants immediately seems to be a highly successful treatment modality. However, long-term data are needed to confirm these positive outcomes. PMID:29732018
Berberi, Antoine N; Sabbagh, Joseph M; Aboushelib, Moustafa N; Noujeim, Ziad F; Salameh, Ziad A
2014-01-01
The aim of present investigation was to evaluate marginal bone level after 5-year follow-up of implants placed in healed ridges and fresh extraction sockets in maxilla with immediate loading protocol. Thirty-six patients in need of a single-tooth replacement in the anterior maxilla received 42 Astra Tech implants (Astra Tech Implant system™, Dentsply Implants, Mölndal, Sweden). Implants were placed either in healed ridges (group I) or immediately into fresh extraction sockets (group II). Implants were restored and placed into functional loading immediately by using a prefabricated abutment. Marginal bone level relative to the implant reference point was recorded at implant placement, crown cementation, 12, 36, and 60 months following loading using intra-oral radiographs. Measurements were made on the mesial and distal sides of each implant. Overall, two implants were lost from the group II, before final crown cementation: they were excluded from the study. The mean change in marginal bone loss (MBL) after implant placement was 0.26 ± 0.161 mm for 1 year, and 0.26 ± 0.171 mm for 3 years, and 0.21 ± 0.185 mm for 5 years in extraction sockets and was 0.26 ± 0.176 mm for 1 year and 0.21 ± 0.175 mm for 3 years, and 0.19 ± 0.172 mm for 5 years in healed ridges group. Significant reduction of marginal bone was more pronounced in implants inserted in healed ridges (P < 0.041) compared to fresh surgical extraction sockets (P < 0.540). Significant MBL was observed on the mesial side of the implant after cementation of the provisional (P < 0.007) and after 12 months (P < 0.034) compared to the distal side which remained stable for 3 and 5 years observation period. Within the limitations of this study, responses of local bone to immediately loaded implants placed either in extraction sockets or healed ridges were similar. Functional loading technique by using prefabricated abutment placed during the surgery time seems to maintain marginal bone around implant in both healed and fresh extraction sites.
Influence of controlled immediate loading and implant design on peri-implant bone formation.
Vandamme, Katleen; Naert, Ignace; Geris, Liesbet; Vander Sloten, Jozef; Puers, Robert; Duyck, Joke
2007-02-01
Tissue formation at the implant interface is known to be sensitive to mechanical stimuli. The aim of the study was to compare the bone formation around immediately loaded versus unloaded implants in two different implant macro-designs. A repeated sampling bone chamber with a central implant was installed in the tibia of 10 rabbits. Highly controlled loading experiments were designed for a cylindrical (CL) and screw-shaped (SL) implant, while the unloaded screw-shaped (SU) implant served as a control. An F-statistic model with alpha=5% determined statistical significance. A significantly higher bone area fraction was observed for SL compared with SU (p<0.0001). The mineralized bone fraction was the highest for SL and significantly different from SU (p<0.0001). The chance that osteoid- and bone-to-implant contact occurred was the highest for SL and significantly different from SU (p<0.0001), but not from CL. When bone-to-implant contact was observed, a loading (SL versus SU: p=0.0049) as well as an implant geometry effect (SL versus CL: p=0.01) was found, in favour of the SL condition. Well-controlled immediate implant loading accelerates tissue mineralization at the interface. Adequate bone stimulation via mechanical coupling may account for the larger bone response around the screw-type implant compared with the cylindrical implant.
Effects of Immediate and Delayed Loading on the Outcomes of All-on-4 Treatment: A Prospective Study
Najafi, Hossein; Siadat, Hakimeh; Rokn, Amirreza
2016-01-01
Objectives: The purpose of this study was to compare the outcomes of immediate and delayed rehabilitation of edentulous jaws by means of two straight and two tilted implants after one year of function. Materials and Methods: Thirty consecutive patients (16 males, 14 females) were enrolled in this study. Two anterior straight and two posterior tilted implants were placed in each patient. According to the implant insertion torque and the need for bone grafting, implants were loaded immediately (at 72 hours) or delayed (after four months) using a fixed metal resin prosthesis. Results: One axial implant failed in the delayed group after one year of loading, resulting in cumulative implant survival rate of 99.3%. The mean marginal bone loss was 0.84mm. No significant difference was found between axial and tilted implants in the two groups (P>0.05) Conclusions: Based on the results, immediate or delayed fabrication of final prosthesis on two tilted and two axial implants did not result in significant differences in survival rates or marginal bone loss. PMID:28243303
Sennerby, L; Gottlow, J
2008-06-01
Two previous reviews have evaluated the clinical outcomes of immediate/early loading of dental implants based on studies published until 2005.(1,2) The aim of the present paper was to review controlled clinical studies on the subject published since 2005 including at least 10 patients in each group followed for at least one year in function. Six comparative studies were found and none of these showed any differences in survival rates or marginal bone loss after one to five years. Most authors used specified inclusion criteria to avoid known risk factors such as soft bone, short implants and bruxism. Data from one randomized study in the edentulous maxilla showed no differences between early and delayed loading in consecutive clinical routine cases including short implants and soft bone. Three additional studies comparing different surfaces or implant designs under immediate loading were reviewed. No differences between implants with a moderately rough or smooth surface topography were observed. The data add to the previous bulk of evidence that various designs of implants can be loaded shortly after their placement in both the mandible and the maxilla. However, one study reported on marginal bone loss around a novel one-piece implant design leading to implant failure which was not seen for control two-piece implants.(3).
Shaarawy, Mohammed A; Aboelross, Ehab M
2013-06-01
This study was carried out to evaluate the effect of varying implant position in immediately loaded implant-supported mandibular overdentures on peri-implant bone density, muscle activity, and patient satisfaction. Fourteen completely edentulous patients were selected for the study. After complete denture construction, patients were divided into 2 equal groups. Four dental implants were installed bilaterally in the interforaminal region in the first group, while in the second group, 4 dental implants were inserted bilaterally: 2 in the interforaminal region and 2 in the first molar area. Immediately after suturing, telescopic abutments were screwed to the implants, and the retaining caps were picked up into the fitting surface of the lower denture, which was delivered to the patient. Patients were recalled for radiographic bone density evaluation just after denture delivery and then at 3, 6, and 12 months thereafter. Muscle activities of masseter and temporalis muscles as well as patient satisfaction were also evaluated. The results of the study showed a high success rate approximating 98.2% of the immediately loaded implants. The electromyographic (EMG) records of both muscles in group 1 were significantly higher during chewing hard food after 3 months compared with group 2 (P < .05). Bone density changes were comparable in the 2 groups except at the end of the follow-up period, when group 2 showed a significant increase in peri-implant bone density values of the posteriorly placed implants compared with group 1 (P < .05). From the results of this study, it may be concluded that wide distribution of immediately loaded implants used for supporting mandibular overdentures through posterior placement beyond the interforaminal area results in a favorable response in terms of increased peri-implant bone density as well as decreased EMG activity of masseter and temporalis muscles.
Imburgia, Mario; Del Fabbro, Massimo
2015-10-01
Studies are needed to evaluate long-term performance of immediately loaded implants with moderately rough surface. This retrospective study evaluated long-term survival and periimplant soft and hard tissue conditions in patients treated with TiUnite implants. Forty-one consecutive patients (mean age, 52.6 years) received 205 Brånemark System Mk III TiUnite implants (145 maxillary, 60 mandibular). The indication was single tooth (n = 7 implants), partial (n = 94), or full arches (n = 104). One hundred thirteen implants were immediately loaded. Cumulative survival rate (CSR) of implants was assessed. Long-term marginal bone remodeling, probing pocket depth (PPD), and periimplant mucosa conditions were assessed. Follow-up averaged 8.8 years (range, 6.6-10.6 years). Eight implants in 5 patients failed. CSR was 96.1% (implant basis) and 87.8% (patient basis) up to 10 years. At the longest follow-up, bone loss averaged 0.43 ± 1.15 mm (n = 173), PPD averaged 3.64 ± 0.74 mm, and periimplant mucosa was healthy in 74.6% of cases. Furthermore, 50.3% and 35.5% of implants scored negative for plaque and bleeding, respectively. No significant difference in CSR and hard and soft tissue conditions was found in the long term between immediately and delayed loaded implants. Implants with TiUnite surface demonstrated excellent long-term survival, marginal bone response, and soft tissue conditions, despite a nonoptimal level of oral hygiene.
Oxby, Gert; Oxby, Fredrik; Oxby, Johan; Saltvik, Tomas; Nilsson, Peter
2015-10-01
Immediate placement of implants in extraction sockets for early loading is an attractive treatment modality due to reduced treatment time. However, the outcome of fluoridated implants in this situation with regard to bone levels and health of soft tissues is not well documented. To evaluate the outcome of early loading of OsseoSpeed(™) dental implants placed into fresh extraction sockets and healed bone in consecutive patients treated in a private clinic. A total of 182 OsseoSpeed(™) implants (Astra Tech Implant System, DENTSPLY Implants, Mölndal, Sweden), 72 in immediate extraction sockets and 110 in healed sites, were placed in 39 consecutive patients. The implants were loaded with permanent restorations within 60 days (average 31 days). Clinical and radiographic follow-up examinations were performed annually for at least 3 years (mean 55 months). An aesthetic index was used to evaluate the soft tissues adjacent to the prosthetic restorations. No implant was lost during the observation period, giving a survival rate of 100%. Bone level changes during the observation period were minimal, with a mean marginal bone loss of 0.3 ± 0.9 mm around the delayed implants and a mean marginal bone gain of 0.3 ± 1.4 mm around the immediate implants (p = .0036). The frequency distribution of bone level revealed that 85% of implants placed in fresh extraction sockets and 84% of implants in healed bone did not show any loss of bone level during follow-up (p = NS). Soft tissue complications were observed at two immediate implant sites in one patient. The remaining 180 implants received the highest aesthetic score. Moreover, no signs of peri-implant purulent infection or aggressive bone loss were found during the follow-up period. Early loading of fluoridated implants with permanent constructions appears to be a viable therapy for implants placed immediately in extraction sites and in healed bone. © 2014 Wiley Periodicals, Inc.
Muelas-Jiménez, M Isabel; Olmedo-Gaya, Maria Victoria; Manzano-Moreno, Francisco J; Reyes-Botella, Candela; Vallecillo-Capilla, Manuel
2017-02-01
To compare survival rates among dental implants restored with immediate, early, and conventional loading protocols, also comparing between maxillary and mandibular implants, and to evaluate the influence of implant length and diameter and the type of prosthesis on treatment outcomes. This retrospective cohort study initially included all 52 patients receiving dental implants between July 2006 and February 2008 at a private oral surgery clinic in Granada (Southern Spain). Clinical and radiographic examinations were performed, including periapical or panoramic radiographs, and incidences during completion of the restoration were recorded at 1 week, 3 months, 6 months, and at 1, 2, 3, 4, and 5 years. After a 5-year follow-up, 1 patient had died, 3 were lost to follow-up, and 6 required grafting before implant placement; therefore, the final study sample comprised 42 patients with 164 implants. Variables associated with the survival/failure of the restoration were: number of implants (higher failure rate with fewer implants), bone type (higher failure rate in type III or IV bone), and type of prosthesis (higher failure rate with single crowns). No significant association was found in univariate or multivariate analyses between survival rate and the loading protocol, implant length or diameter, or maxillary/mandibular location. Immediate occlusal loading, immediate provisionalization without occlusal loading, and early loading are viable treatment options with similar survival rates to those obtained with conventional loading. Bone quality and number of implants per patient were the most influential factors. © 2015 by the American College of Prosthodontists.
When is an implant ready for a tooth?
Tupac, Robert G
2003-12-01
The capability of placing an osseointegrated implant at the time of tooth extraction and immediately placing a restoration on the implant depends upon a number of factors. This paper describes the traditional Brånemark protocol, the evolution of single-stage surgery, the guidelines for immediate placement, the measurement of implant stability, and the considerations critical to immediately loading.
MILILLO, L.; FIANDACA, C.; GIANNOULIS, F.; OTTRIA, L.; LUCCHESE, A.; SILVESTRE, F.; PETRUZZI, M.
2016-01-01
SUMMARY Purpose This study aims to evaluate differences in implant stability between post-extractive implants vs immediately placed post-extractive implants by resonance frequency analysis (RFA). Materials and methods Patients were grouped into two different categories. In Group A 10 patients had an immediate post-extractive implant, then a provisional, acrylic resin crown was placed (immediate loading). In Group B (control group) 10 patients only had an immediate post-extractive implant. Both upper and lower premolars were chosen as post-extractive sites. Implant Stability Quotient (ISQ) was measured thanks to RFA measurements (Osstell®). Five intervals were considered: immediately after surgery (T0) and every four weeks, until five months after implant placement (T1, T2, T3, T4,T5). A statistical analysis by means of Student’s T-test (significance set at p<0.05) for independent sample was carried out in order to compare Groups A and B. Results The ISQ value between the two groups showed a statistically significant difference (p<0.02) at T1. No statistically significant difference in ISQ was assessed at T0, T2, T3, T4 and T5. Conclusions After clinical assessment it is possible to confirm that provisional and immediate prosthetic surgery in post-extraction sites with cone-shaped implants, platform-switching abutment and bioactive surface can facilitate osseointegration, reducing healing time. PMID:28042440
Todorovic, Vladimir S; Vasovic, Miroslav; Beetge, Mia-Michaela; van Zyl, Andre W; Kokovic, Vladimir
2017-02-01
The objective of the present study was to elucidate stability development of immediately loaded hybrid self-tapping implants inserted in the posterior maxilla. Forty-eight hybrid self-tapping implants with a chemically modified surface (∅4.1; length: 8 mm) were inserted bilaterally in the maxillary first and second premolar and first molar sites of 8 patients. In each patient, both sides of the maxilla were assigned randomly to either immediate (IL) or early (EL) loading group. Implant stability was evaluated by means of resonance frequency analysis immediately after implant placement and after 1, 2, 3, 4, 5, 6, 12, 26, and 52 weeks. High values of primary stability were found in both groups (71.91 ± 6.52 implant stability quotient [ISQ] in IL group; 73.87 ± 6.5 ISQ in EL group), with significant differences between the groups at the different time points. Initial decrease in stability was observed between the first and fifth weeks in the IL group and between the first and third weeks for the EL group. In the IL group 1 implant was removed after 3 weeks due to lack of stability. Early results of this study showed the ability of hybrid self-tapping dental implants with a chemically modified surface to achieve sufficient primary stability and to maintain high values of secondary implant stability in bone type 3 and 4, even when loaded immediately. Minimal alterations in stability were observed for both investigated groups, but the EL group showed faster recovery after an initial drop in stability.
Vanden Bogaerde, Leonardo; Sennerby, Lars
2016-01-01
Background. Hydrophilic and moderately rough implant surfaces have been proposed to enhance the osseointegration response. Aim. The aim of this study was to compare early changes of stability for two implants with identical macrodesign but with different surface topographies. Materials and Methods. In 11 patients, a total of 22 implants (11 bimodal (minimally rough, control) and 11 proactive (moderately rough and hydrophilic, test), Neoss Ltd., Harrogate, UK) were immediately placed into fresh extraction sockets and immediately loaded. The peak insertion torque (IT) was measured in Ncm at placement. Resonance Frequency Analysis (RFA) measurements were made at baseline and 2, 4, 6, and 12 weeks after surgery. Results. The two implant types showed similar IT and RFA values at placement (NS). A dip of RFA values after 2 weeks followed by an increase was observed, where the test implant showed a less pronounced decrease and a more rapid recovery than the control implant. The test implants were significantly more stable than the control ones after 12 weeks. Conclusions. The results from the present study indicated that the hydrophilic and rougher test implant was more resistant to immediate loading and showed a significantly higher stability than the smoother control implant after 12 weeks. PMID:27042180
Immediate loading of unsplinted implants in the anterior mandible for overdentures: 3-year results.
Roe, Phillip; Kan, Joseph Y K; Rungcharassaeng, Kitichai; Lozada, Jaime L
2011-01-01
This 3-year study evaluated the implant survival rate, peri-implant tissue response, prosthetic maintenance, and prosthetic complications in a series of patients who received two immediately loaded unsplinted threaded implants to retain a mandibular overdenture. Eight completely edentulous patients were evaluated clinically and radiographically immediately after implant placement, at 3 months, and at 1, 2, and 3 years after implant placement. Data were analyzed using repeated-measures one-way analysis of variance and the Wilcoxon signed rank test at a significance level of α = .05. At 3 years, all implants remained osseointegrated (16/16), with an overall mean marginal bone change of -0.58 ± 0.39 mm and a mean Periotest value of -7.19 ± 0.54. The modified Plaque Index scores showed marked improvement in oral hygiene during the first year, but some relapse was observed thereafter. Prosthetic maintenance and complications included replacement of the attachment inserts, abutment loosening, dislodgement of the attachment housing, overdenture reline, denture tooth fracture, and overdenture base fracture. This 3-year study suggests that, despite less than ideal oral hygiene and a high incidence of complete/partial fracture of overdentures, favorable implant survival rate and peri-implant tissue responses can be achieved in mandibular overdentures retained with two immediately loaded unsplinted threaded implants.
Critical review of immediate implant loading.
Gapski, Ricardo; Wang, Hom-Lay; Mascarenhas, Paulo; Lang, Niklaus P
2003-10-01
Implant dentistry has become successful with the discovery of the biological properties of titanium. In the original protocol, studies have advocated a 2-stage surgical protocol for load-free and submerged healing to ensure predictable osseointegration. However, the discomfort, inconvenience, and anxiety associated with waiting period remains a challenge to both patients and clinicians. Hence, loading implant right after placement was attempted and has gained popularity among clinicians. Issues/questions related to this approach remain unanswered. Therefore, it is the purpose of this review article to (1). review and analyze critically the current available literature in the field of immediate implant loading and (2). discuss, based on scientific evidence, factors that may influence this treatment modality. Literature published over the past 20 years was selected and reviewed. Findings from these studies were discussed and summarized in the tables. The advantages and disadvantages associated with immediate implant loading were analyzed. Factors that may influence the success of immediate implant loading, including patient selection, type of bone quality, required implant length, micro- and macrostructure of the implant, surgical skill, need for achieving primary stability/control of occlusal force, and prosthesis guidelines, were thoroughly reviewed and discussed. Various studies have demonstrated the feasibility and predictability of this technique. However, most of these articles are based on retrospective data or uncontrolled cases. Randomized, prospective, parallel-armed longitudinal human trials are primarily based on short-term results and long-term follow-ups are still scarce in this field. Nonetheless, from available literature, it may be concluded that anatomic locations, implant designs, and restricted prosthetic guidelines are key to ensure successful outcomes. Future studies, preferably randomized, prospective longitudinal studies, are certainly needed before this approach can be widely used.
Berberi, Antoine N.; Sabbagh, Joseph M.; Aboushelib, Moustafa N.; Noujeim, Ziad F.; Salameh, Ziad A.
2014-01-01
Purpose: The aim of present investigation was to evaluate marginal bone level after 5-year follow-up of implants placed in healed ridges and fresh extraction sockets in maxilla with immediate loading protocol. Materials and Methods: Thirty-six patients in need of a single-tooth replacement in the anterior maxilla received 42 Astra Tech implants (Astra Tech Implant system™, Dentsply Implants, Mölndal, Sweden). Implants were placed either in healed ridges (group I) or immediately into fresh extraction sockets (group II). Implants were restored and placed into functional loading immediately by using a prefabricated abutment. Marginal bone level relative to the implant reference point was recorded at implant placement, crown cementation, 12, 36, and 60 months following loading using intra-oral radiographs. Measurements were made on the mesial and distal sides of each implant. Results: Overall, two implants were lost from the group II, before final crown cementation: they were excluded from the study. The mean change in marginal bone loss (MBL) after implant placement was 0.26 ± 0.161 mm for 1 year, and 0.26 ± 0.171 mm for 3 years, and 0.21 ± 0.185 mm for 5 years in extraction sockets and was 0.26 ± 0.176 mm for 1 year and 0.21 ± 0.175 mm for 3 years, and 0.19 ± 0.172 mm for 5 years in healed ridges group. Significant reduction of marginal bone was more pronounced in implants inserted in healed ridges (P < 0.041) compared to fresh surgical extraction sockets (P < 0.540). Significant MBL was observed on the mesial side of the implant after cementation of the provisional (P < 0.007) and after 12 months (P < 0.034) compared to the distal side which remained stable for 3 and 5 years observation period. Conclusions: Within the limitations of this study, responses of local bone to immediately loaded implants placed either in extraction sockets or healed ridges were similar. Functional loading technique by using prefabricated abutment placed during the surgery time seems to maintain marginal bone around implant in both healed and fresh extraction sites. PMID:24550840
Mijiritsky, Eitan; Mortellaro, Carmen; Rudberg, Omri; Fahn, Miri; Basegmez, Cansu; Levin, Liran
2016-05-01
The aim of the present report was to describe the use of Botulinum toxin type A as preoperative treatment for immediately loaded dental implants placed in fresh extraction sockets for full-arch restoration of patients with bruxism. Patients with bruxism who were scheduled to receive immediately loaded full-arch implant supported fixed restorations were included in this retrospective clinical report. To reduce the occlusal forces applied in patients with bruxism, Botulinum toxin type A was introduced prior to the implant placement procedure. Patients were followed and implant survival as well as peri-implant bone level was assessed in each periodic follow-up visit. Adverse effects were also recorded. A control group with no use of Botulinum toxin was evaluated as well. A total of 26 patients (13 test and 13 control), with bruxism, aged 59.15 ± 11.43 years on average were included in this retrospective report and received immediately loaded dental implants placed in fresh extraction sockets for full-arch restoration. The test group treatment preceded by Botulinum toxin type A injection. Maxillary arches were supported by 8 to 10 implants while the mandibular arch was supported by 6 implants. All surgeries went uneventfully and no adverse effects were observed. The average follow-up time was 32.5 ± 10.4 months (range, 18-51). In the test group, no implant failures were recorded. One patient presented with 1 to 2 mm bone loss around 4 of the implants; the other implants presented with stable bone level. In the control group 1 patient lost 2 implants and another demonstrated 2 mm bone loss around 3 of the implants. The preoperative use of Botulinum toxin in patients with bruxism undergoing full-arch rehabilitation using immediately loaded dental implants placed in fresh extraction sockets seems to be a technique that deserves attention. Further long-term, large-scale randomized clinical trials will help to determine the additional benefit of this suggested treatment modality.
Mura, Priamo
2012-08-01
The use of immediate implant loading protocols delivers obvious benefits to the patient. When applied in healed sites, this has not only been well documented in the totally edentolous mandible but has also been documented and reported to be predictable in the upper jaw, and in cases of partial edentoulism, as well. A further application of immediate loading protocol, although still controversial, especially when replacing single maxillary teeth in the anterior zone, is the immediate implant placement and provisionalization in postextractive sockets. In consideration of the oxidized surface promoting bone healing and the tapered shape of the implant body, the Replace Select Tapered TiUnite implants have been used for many years in our clinic when facing these clinical situations. This article will report about our long-term clinical experience with such implants and the relevant role of a correct surgical and prosthetic treatment planning. The aim of this retrospective study was to report on the 5-year clinical and radiologic outcome of patients treated with Replace Select Tapered TiUnite implants when used according to an immediate loading protocol in postextraction sites. In routine practice, 56 consecutive patients were treated with 79 implants. The patients, 23 males and 33 females, had a mean age of 50.9 years, range 21-76 years, at implant placement. Forty-seven implants were placed in the maxilla and 32 implants were placed in the mandible. All implants were placed in postextraction sites and were immediately loaded. Provisional restorations were delivered within 2 hours from surgery and all were in occlusion. Forty-three patients received a single implant while in the remaining 13 patients the implants were splinted. Definitive prosthetic restoration was delivered within 1 to 4 months following implant placement. Evaluations of soft tissue health and marginal bone remodeling were conducted. An independent radiologist performed the radiographic evaluation using the top of the implant as the reference point with negative values indicating a level below the reference point. Forty-eight patients, accounting for 66 implants, have passed the 5-year follow-up. No implants have failed resulting in a 5-year cumulative implant survival rate of 100%. Three patients, with six implants, withdrew during the course of the follow-up; one patient passed away and two patients moved. Five patients with seven implants did not show up at 5 years recall. At the 5-year follow-up, majority of the implants that were followed demonstrated normal periimplant mucosa and no visible plaque. The mean bone level at 5-year follow-up was -2.45mm (SD 1.29, n=63) demonstrating a level in line with the first thread. Mean marginal bone loss from implant inserting to 5 years was 0.56 mm (SD 1.98, n=63). In regard with complications, a fracture of the ceramic crown was reported 5 years after implant insertion in a patient who developed bruxism. No other biologic nor mechanical complications were reported. This retrospective 5-year follow-up study of 56 patients treated with implants immediately placed in postextraction sockets and immediately loaded demonstrates good treatment outcome with regard to implant survival, soft tissue condition, and marginal bone response. © 2010 Wiley Periodicals, Inc.
Levin, Barry P; Wilk, Brian L
2013-05-01
This prospective study evaluates immediately placed and immediately provisionalized implants in the esthetic zone. All implants were TiO2-blasted, fluoride-modified, grade 4 titanium, with a coronal microthread design. Bone grafting and guided bone regeneration (GBR) was performed at all sites, and screw-retained temporary restorations were delivered on the day of surgery. All of the provisional crown(s) were out of occlusal function and remained in place for at least 8 weeks prior to initiation of definitive restorative therapy. Bone maintenance (BM) was considered successful if radiographs demonstrated proximal bone levels even or coronal to the implant platform. Of the 29 implants placed, 25 (86 percent) achieved bone maintenance at least 12 months post-loading with the final restorations. This study was considered successful, with 100 percent implant survival after at least 1 year loading of the final restoration, and 100 percent of patients were satisfied with the esthetics of their implant treatment.
Zygogiannis, Kostas; Wismeijer, Daniel; Aartman, Irene Ha; Osman, Reham B
2016-01-01
Different treatment protocols in terms of number, diameter, and suprastructure design have been proposed for immediately loaded implants that are used to support mandibular overdentures opposed by maxillary conventional dentures. The aim of this study was to investigate the influence of these protocols on survival rates as well as clinical and prosthodontic outcomes. Several electronic databases were searched for all relevant articles published from 1966 to June 2014. Only randomized controlled trials and prospective studies with a minimum follow-up of 12 months were selected. The primary outcomes of interest were the success and survival rates of the implants. Prosthodontic complications were also evaluated. Fourteen studies fulfilled the inclusion criteria. Of the studies identified, nine were randomized controlled trials and five were prospective studies. The mean follow-up period was 3 years or less for the vast majority of the studies. The reported survival and success rates were comparable to that of conventional loading for most of the included studies. No specific immediate loading protocol seemed to perform better in terms of clinical and prosthodontic outcomes. Immediate loading protocols of mandibular overdentures seem to be a viable alternative to conventional loading. It was not possible to recommend a specific treatment protocol related to the number, diameter of the implants, and attachment system used. Long-term, well-designed studies comparing different immediate loading modalities could help to establish a protocol that delivers the most clinically predictable, efficient, and cost-effective outcome for edentulous patients in need of implant overdentures.
Desai, Shrikar R; Singh, Rika; Karthikeyan, I
2013-09-01
The aim of the study is to evaluate the influence implant length on stress distribution at bone implant interface in single immediately loaded implants when placed in D4 bone quality. A 2-dimensional finite element models were developed to simulate two types of implant designs, standard 3.75 mm-diameter tapered body implants of 6 and 10 mm lengths. The implants were placed in D4 bone quality with a cortical bone thickness of 0.5 mm. The implant design incorporated microthreads at the crestal part and the rest of the implant body incorporated Acme threads. The Acme thread form has a 29° thread angle with a thread height half of the pitch; the apex and valley are flat. A 100 N of force was applied vertically and in the oblique direction (at an angle of 45°) to the long axis of the implants. The respective material properties were assigned. Micro-movements and stresses at the bone implant interface were evaluated. The results of total deformation (micro-movement) and Von mises stress were found to be lower for tapered long implant (10 mm) than short implant (6 mm) while using both vertical as well as oblique loading. Short implants can be successfully placed in poor bone quality under immediate loading protocol. The novel approach of the combination of microthreads at the crestal portion and acme threads for body portion of implant fixture gave promising results.
Kaneko, Takahiro; Yamagishi, Kiyoshi; Horie, Norio; Shimoyama, Tetsuo
2013-01-01
To evaluate the clinical outcome of a novel open-tray impression technique for fabrication of a provisional prosthesis supported by immediately loaded implants in a completely edentulous arch. An open-tray impression technique was evaluated in this retrospective study that included patients treated between March 2006 and October 2009. Preoperatively, a diagnostic prosthesis was delivered, and a novel open tray was fabricated based on this prosthesis. After implant placement, the impression and interocclusal record were taken simultaneously using the novel open tray. Laboratory-fabricated, screw-retained, all-acrylic resin provisional restorations were delivered on the same day of surgery. The prosthesis was assessed from the day of surgery until replacement with a definitive prosthesis. The study included 21 patients (mean age, 64.5 years) and a total of 125 implants. Of these, 104 implants were immediately loaded. In all patients, well-fitting provisional restorations supported by a minimum of four implants were delivered. Fracture of the first molar cusp was observed in one case after 30 days. However, there was no extensive fracture in the framework or functional disorder of the prosthesis. No implant failed during the follow-up after implant surgery. This protocol enabled fabrication of a well-fitting acrylic resin provisional prosthesis supported by immediately loaded implants because the impression was taken while in centric occlusion and an occlusion identical to the diagnostic prosthesis could be reconstructed.
2014-01-01
Background Over the years, there has been a strong consensus in dentistry that at least two implants are required to retain a complete mandibular denture. It has been shown in several clinical trials that one single median implant can retain a mandibular overdenture sufficiently well for up to 5 years without implant failures, when delayed loading was used. However, other trials have reported conflicting results with in part considerable failure rates when immediate loading was applied. Therefore it is the purpose of the current randomized clinical trial to test the hypothesis that immediate loading of a single mandibular midline implant with an overdenture will result in a comparable clinical outcome as using the standard protocol of delayed loading. Methods/design This prospective nine-center randomized controlled clinical trial is still ongoing. The final patient will complete the trial in 2016. In total, 180 edentulous patients between 60 and 89 years with sufficient complete dentures will receive one median implant in the edentulous mandible, which will retain the existing complete denture using a ball attachment. Loading of the median implant is either immediately after implant placement (experimental group) or delayed by 3 months of submerged healing at second-stage surgery (control group). Follow-up of patients will be performed for 24 months after implant loading. The primary outcome measure is non-inferiority of implant success rate of the experimental group compared to the control group. The secondary outcome measures encompass clinical, technical and subjective variables. The study was funded by the Deutsche Forschungsgemeinschaft (German research foundation, KE 477/8-1). Discussion This multi-center clinical trial will give information on the ability of a single median implant to retain a complete mandibular denture when immediately loaded. If viable, this treatment option will strongly improve everyday dental practice. Trial registration The trial has been registered at Deutsches Register Klinischer Studien (German register of clinical trials) under DRKS-ID: DRKS00003730 since 23 August 2012. (http://www.germanctr.de). PMID:24884848
Immediate loading of implants in the aesthetic zone: comparison between two placement timings.
Carini, Fabrizio; Longoni, Salvatore; Pisapia, Valeria; Francesconi, Manuel; Saggese, Vito; Porcaro, Gianluca
2014-01-01
Implant rehabilitation delivered in accordance with the traditional protocol has proven to be highly predictable and acceptable (1). Nevertheless, the application of immediate loading on post-extraction implants, especially for aesthetic zones, has now considerably increased (2). The aim of this work is to illustrate the immediate loading of implants placed in the aesthetic zone through tapered design fixtures with microgeometry of a high degree of porosity inserted at the same time or 4-8 weeks from dental avulsion (TSA® Advance, Phibo®). A total of 15 implant fixtures of which 8 at an interval of 4-8 weeks from extraction (type 2) and the remaining according to the immediate post-extraction technique (type 1) were positioned. All implants were prosthesized within 24 hours from the placement. Definitive crowns replaced provisional restorations after 20-24 weeks. After 4 and 12 months from implant insertion, the following parameters were assessed: X-ray image, pain, mobility or suppuration, soft tissue condition and aesthetic appearance. Percentage of osseointegration was 93.75%, and 53.5% of the osseointegrated fixtures was type 2. No statistically significant difference between the mean ISQ values for implants of type 1 and 2 both in the post-operative period and after 12 months was evident, indicating that the timing of insertion did not affect the achievement of stability for the implant fixtures tested in our study. Immediate post-extraction implants showed a greater propensity for gingival recession and a peri-implant radiolucency greater than those placed at an interval of 4-8 weeks. The values obtained for the PES/WES and the subjective evaluation of the analyzed sample showed the considerable aesthetic value and the high level of satisfaction guaranteed by the implant technique illustrated. Although well-designed, high quality, randomized clinical trials are still needed as well as the requirement to establish a common, complete, and reproducible index for the evaluation of aesthetic outcome, immediate/early placement and loading of a single TSA® Advance, Phibo® may be considered a valuable and predictable option in terms of implant success as well as hard and soft tissue stability.
Fazel, Akbar; Aalai, Shima; Rismanchian, Mansour
2009-08-01
Macro-design influences the initial stability of implant and reduces micromotions. The aim of this study was to determine and compare micromotions and stress distribution in the bone around immediately loaded Maestro and Xive implants using finite element analysis. In this experimental study, accurate, clear photos were prepared of Xive and Maestro implants 12 and 13 mm long and 4 and 3.8 mm in diameter, respectively, using a Nikon Digital Camera with a resolution 5.24-megapixels with 8x Optical Zoom and 4x Digital Zoom. After accurate measurements, 3-D models of the implants inside the lower mandible (D2) were processed in Solidworks Version 2003 environment and transferred into Ansys for finite element analysis. After loading of 500 N angled at 70 degrees from the horizontal plane, the micromotion of the implant and Von Misses stresses around the bone were measured. The measured micromotion in Maestro implant was 148 mum and that in Xive was 284 mum. Stress distribution in the bone surrounding Maestro implant was better than Xive, but maximum stress surrounding Xive implants (30 MPa) was lower than Maestro (33 MPa). Based on the results obtained in the present study, maximum micromotion in maestro was less than that in Xive implants. This finding can guarantee the application of maestro implants for immediate loading.
Ding, Xi; Zhu, Xing-Hao; Liao, Sheng-Hui; Zhang, Xiu-Hua; Chen, Hong
2009-07-01
To establish a 3D finite element model of a mandible with dental implants for immediate loading and to analyze stress distribution in bone around implants of different diameters. Three mandible models, embedded with thread implants (ITI, Straumann, Switzerland) with diameters of 3.3, 4.1, and 4.8 mm, respectively, were developed using CT scanning and self-developed Universal Surgical Integration System software. The von Mises stress and strain of the implant-bone interface were calculated with the ANSYS software when implants were loaded with 150 N vertical or buccolingual forces. When the implants were loaded with vertical force, the von Mises stress concentrated on the mesial and distal surfaces of cortical bone around the neck of implants, with peak values of 25.0, 17.6 and 11.6 MPa for 3.3, 4.1, and 4.8 mm diameters, respectively, while the maximum strains (5854, 4903, 4344 muepsilon) were located on the buccal cancellous bone around the implant bottom and threads of implants. The stress and strain were significantly lower (p < 0.05) with the increased diameter of implant. When the implants were loaded with buccolingual force, the peak von Mises stress values occurred on the buccal surface of cortical bone around the implant neck, with values of 131.1, 78.7, and 68.1 MPa for 3.3, 4.1, and 4.8 mm diameters, respectively, while the maximum strains occurred on the buccal surface of cancellous bone adjacent to the implant neck, with peak values of 14,218, 12,706, and 11,504 microm, respectively. The stress of the 4.1-mm diameter implants was significantly lower (p < 0.05) than those of 3.3-mm diameter implants, but not statistically different from that of the 4.8 mm implant. With an increase of implant diameter, stress and strain on the implant-bone interfaces significantly decreased, especially when the diameter increased from 3.3 to 4.1 mm. It appears that dental implants of 10 mm in length for immediate loading should be at least 4.1 mm in diameter, and uniaxial loading to dental implants should be avoided or minimized.
Lombardo, Giorgio; Corrocher, Giovanni; Pighi, Jacopo; Mascellaro, Anna; Marincola, Mauro; Nocini, Per Francesco
2016-06-01
The purpose of this study was to evaluate the esthetic outcome of single-tooth locking taper connection implants placed in the anterior maxilla following a postextractive nonfunctional loading protocol. This preliminary clinical study involving 16 patients evaluated the results of 21 implants placed in areas with high esthetic value. For each implant the pink esthetic score, white esthetic score, cumulative survival rate, and health status of peri-implant tissues were evaluated. The cumulative survival rate was 100% 2 years after prosthetic loading, and the mean total pink esthetic score/white esthetic score was 16.9 ± 1.14 on a maximum value of 20. There was excellent plaque control in all patients, and inflammation indices were within the norm. Within the limits of this study, this immediate nonfunctional loading protocol seems to be a successful procedure esthetically and for the maintenance of peri-implant soft tissues.
Desai, Shrikar R.; Singh, Rika; Karthikeyan, I.
2013-01-01
Aim: The aim of the study is to evaluate the influence implant length on stress distribution at bone implant interface in single immediately loaded implants when placed in D4 bone quality. Materials and Methods: A 2-dimensional finite element models were developed to simulate two types of implant designs, standard 3.75 mm–diameter tapered body implants of 6 and 10 mm lengths. The implants were placed in D4 bone quality with a cortical bone thickness of 0.5 mm. The implant design incorporated microthreads at the crestal part and the rest of the implant body incorporated Acme threads. The Acme thread form has a 29° thread angle with a thread height half of the pitch; the apex and valley are flat. A 100 N of force was applied vertically and in the oblique direction (at an angle of 45°) to the long axis of the implants. The respective material properties were assigned. Micro-movements and stresses at the bone implant interface were evaluated. Results: The results of total deformation (micro-movement) and Von mises stress were found to be lower for tapered long implant (10 mm) than short implant (6 mm) while using both vertical as well as oblique loading. Conclusion: Short implants can be successfully placed in poor bone quality under immediate loading protocol. The novel approach of the combination of microthreads at the crestal portion and acme threads for body portion of implant fixture gave promising results. PMID:24174759
Pellicer-Chover, Hilario; Peñarrocha-Oltra, David; Bagán, Leticia; Fichy-Fernandez, Antonio J.; Canullo, Luigi
2014-01-01
Purpose: To evaluate and compare peri-implant health, marginal bone loss and success of immediate and delayed implant placement for rehabilitation with full-arch fixed prostheses. Material and Methods: The present study was a prospective, randomized, single-blind, clinical preliminary trial. Patients were randomized into two treatment groups. In Group A implants were placed immediately post-extraction and in Group B six months after extraction. The following control time-points were established: one week, six months and twelve months after loading. Measurements were taken of peri-implant crevicular fluid volume, plaque index, gingival retraction, keratinized mucosa, probing depth, modified gingival index and presence of mucositis. Implant success rates were evaluated for the two groups. The study sample included fifteen patients (nine women and six men) with a mean average age of 63.7 years. One hundred and forty-four implants were placed: 76 placed in healed sites and 68 placed immediately. Results: At the moment of prosthetic loading, keratinized mucosa width and probing depth were higher in immediate implants than delayed implants, with statistically significant differences. However, after six and twelve months, differences between groups had disappeared. Bone loss was 0.54 ± 0.39 mm for immediate implants and 0.66 ± 0.25 mm for delayed implants (p=0.201). No implants failed in either group. Conclusions: The present study with a short follow-up and a small sample yielded no statistically significant differences in implant success and peri-implant marginal bone loss between immediate and delayed implants with fixed full-arch prostheses. Peri-implant health showed no statistically significant differences for any of the studied parameters (crevicular fluid volume, plaque index, gingival retraction, keratinized mucosa, probing depth, modified gingival index and presence of mucositis) at the twelve-month follow-up. Key words:Immediate implants, delayed implants, peri-implant health, success rate. PMID:24316712
Hasan, Istabrak; Heinemann, Friedhelm; Schwegmann, Monika; Keilig, Ludger; Stark, Helmut; Bourauel, Christoph
2017-02-01
Small diameter (mini) dental implants have become more popular in recent years as alternatives to classical implant treatment in clinical cases with critical bony situations. However, an in-depth scientific analysis of the mechanical and biomechanical effects of small diameter implants has not yet been published. The aim of the present study was to investigate experimentally different commercial mini implants by measuring their displacements under immediate loading. Twelve commercially available mini implants were measured. Implants were inserted into porcine mandibular segments and loaded by means of a predefined displacement of 0.5 mm of the loading system. The implants were loaded at an angle of 30° to the implant long axis using the self-developed biomechanical hexapod measurement system. Implant displacements were registered. The experimental results were compared to the numerical ones from a previous study. Measured implant displacements were within the range of 39-194 μm. A large variation in the displacements was obtained among the different implant systems due to the different designs and thread profiles. Comparing experimental and numerical results, the displacements that were obtained numerically were within the range of 79-347 μm. The different commercial mini implants showed acceptable primary stability and could be loaded immediately after their insertion.
Yan, Xu; Zhang, Xinwen; Chi, Weichao; Ai, Hongjun; Wu, Lin
2015-05-01
This study aimed to compare the influence of alveolar ridge cortical bone and sinus floor cortical bone in sinus areabi-cortical dental implantation by means of 3D finite element analysis. Three-dimensional finite element (FE) models in a posterior maxillary region with sinus membrane and the same height of alveolar ridge of 10 mm were generated according to the anatomical data of the sinus area. They were either with fixed thickness of crestal cortical bone and variable thickness of sinus floor cortical bone or vice versa. Ten models were assumed to be under immediate loading or conventional loading. The standard implant model based on the Nobel Biocare implant system was created via computer-aided design software. All materials were assumed to be isotropic and linearly elastic. An inclined force of 129 N was applied. Von Mises stress mainly concentrated on the surface of crestal cortical bone around the implant neck. For all the models, both the axial and buccolingual resonance frequencies of conventional loading were higher than those of immediate loading; however, the difference is less than 5%. The results showed that bi-cortical implant in sinus area increased the stability of the implant, especially for immediately loading implantation. The thickness of both crestal cortical bone and sinus floor cortical bone influenced implant micromotion and stress distribution; however, crestal cortical bone may be more important than sinus floor cortical bone.
Albiero, Alberto Maria; Benato, Renato
2016-09-01
Complications are frequently reported when combining computer assisted flapless surgery with an immediate loaded prefabricated prosthesis. The authors have combined computer-assisted surgery with the intraoral welding technique to obtain a precise passive fit of the immediate loading prosthesis. An edentulous maxilla was rehabilitated with four computer assisted implants welded together intraorally and immediately loaded with a provisional restoration. A perfect passive fit of the metal framework was obtained that enabled proper osseointegration of implants. Computer assisted preoperative planning has been shown to be effective in reducing the intraoperative time of the intraoral welding technique. No complications were observed at 1 year follow-up. This guided-welded approach is useful to achieve a passive fit of the provisional prosthesis on the inserted implants the same day as the surgery, reducing intraoperative time with respect to the traditional intraoral welding technique. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Stress on external hexagon and Morse taper implants submitted to immediate loading
Odo, Caroline H.; Pimentel, Marcele J.; Consani, Rafael L.X.; Mesquita, Marcelo F.; Nóbilo, Mauro A.A.
2015-01-01
Background/Aims This study aimed to evaluate the stress distribution around external hexagon (EH) and Morse taper (MT) implants with different prosthetic systems of immediate loading (distal bar (DB), casting technique (CT), and laser welding (LW)) by using photoelastic method. Methods Three infrastructures were manufactured on a model simulating an edentulous lower jaw. All models were composed by five implants (4.1 mm × 13.0 mm) simulating a conventional lower protocol. The samples were divided into six groups. G1: EH implants with DB and acrylic resin; G2: EH implants with titanium infrastructure CT; G3: EH implants with titanium infrastructure attached using LW; G4: MT implants with DB and acrylic resin; G5: MT implants with titanium infrastructure CT; G6: MT implants with titanium infrastructure attached using LW. After the infrastructures construction, the photoelastic models were manufactured and a loading of 4.9 N was applied in the cantilever. Five pre-determined points were analyzed by Fringes software. Results Data showed significant differences between the connection types (p < 0.0001), and there was no significant difference among the techniques used for infrastructure. Conclusion The reduction of the stress levels was more influenced by MT connection (except for CT). Different bar types submitted to immediate loading not influenced stress concentration. PMID:26605142
García-Roncero, Herminio; Caballé-Serrano, Jordi; Cano-Batalla, Jordi; Cabratosa-Termes, Josep; Figueras-Álvarez, Oscar
2015-04-01
In this study, a temporal abutment fixation screw, designed to fracture in a controlled way upon application of an occlusal force sufficient to produce critical micromotion was developed. The purpose of the screw was to protect the osseointegration of immediate loaded single implants. Seven different screw prototypes were examined by fixing titanium abutments to 112 Mozo-Grau external hexagon implants (MG Osseous®; Mozo-Grau, S.A., Valladolid, Spain). Fracture strength was tested at 30° in two subgroups per screw: one under dynamic loading and the other without prior dynamic loading. Dynamic loading was performed in a single-axis chewing simulator using 150,000 load cycles at 50 N. After normal distribution of obtained data was verified by Kolmogorov-Smirnov test, fracture resistance between samples submitted and not submitted to dynamic loading was compared by the use of Student's t-test. Comparison of fracture resistance among different screw designs was performed by the use of one-way analysis of variance. Confidence interval was set at 95%. Fractures occurred in all screws, allowing easy retrieval. Screw Prototypes 2, 5 and 6 failed during dynamic loading and exhibited statistically significant differences from the other prototypes. Prototypes 2, 5 and 6 may offer a useful protective mechanism during occlusal overload in immediate loaded implants.
Scala, Rudy; Cucchi, Alessandro; Ghensi, Paolo; Vartolo, Francesco
2012-01-01
The purpose of this controlled prospective study was to compare the satisfaction of patients rehabilitated with an immediately loaded implant-supported prosthesis and patients rehabilitated with a conventional denture in the mandible. Selected mandibular partially or totally edentulous patients were included in this prospective study. Patients' mandibles were completely rehabilitated with immediately loaded implants supporting a screw-retained full-arch prosthesis (test group) or with a conventional denture (control group). The Satisfaction Profile (SAT-P), which investigates a number of psychologic aspects related to the function and esthetics of the stomatognathic apparatus, was administered to each patient 1 month before and 3 months after provisional prosthetic rehabilitation. The questionnaire comprised four different SAT-P items: quality of eating, eating behavior, mood, and self-confidence. A visual analog scale was used to elicit patient responses. SAT-P item scores were analyzed statistically by means of the Student t test and the chi-square test (or the Mann-Whitney nonparametric test), with P < .05 considered significant. Forty-one patients were consecutively treated with 205 immediately loaded implants supporting a screw-retained full-arch prosthesis (test group); 38 patients were consecutively treated with a conventional denture (control group). Statistically significant differences were observed between the test and control groups for all four SAT-P items. The test group reported greater satisfaction for all items versus the control group. In both groups, the differences between pre- and postrehabilitation values were statistically significant. Each patient was satisfied with their treatment outcomes, but patients who received an implant-supported prosthesis were more satisfied than the patients who received a conventional denture. The results suggest that a screw-retained full-arch prosthesis on immediately loaded implants is a predictable means of enhancing patient satisfaction.
Maló, Paulo; Nobre, Miguel de Araújo; Lopes, Armando; Ferro, Ana; Gravito, Inês
2014-01-01
To report the 5-year outcome of immediately loaded dental implants in patients with untreated periodontal disease. This prospective cohort study included 103 consecutive patients (51 females and 52 males) with an average age of 52 years (range: 22 to 80 years) who were rehabilitated with 380 implants supporting 145 prostheses in both jaws (40 single; 33 partial and 72 complete rehabilitations). The implants were inserted in patients with active and untreated periodontitis. The patients did not receive any previous periodontal treatment before implant surgery, except for an oral hygiene session immediately before the implant surgery. In maintenance (every 6 months) patients received periodontal treatment as needed. Outcome measures were: prostheses failures; implant failures; complications; and marginal bone level changes. Fifteen patients dropped out of the study (14.6%). Two patients lost two implants (FDI positions nos.12 and 42), rendering a cumulative survival rate of 97.9% and 99.4% at 5 years of followup using the patient and implant as unit of analysis, respectively. The average (standard deviation) marginal bone resorption was 0.71 mm (0.42 mm) at 5 years. Mechanical complications occurred in 14 patients, consisting of prostheses fractures (10 provisional prostheses and 4 definitive prostheses). Thirteen implants (3.9%) in 13 patients (14.8%) presented peri-implant pathology. Within the limitations of this study, it is possible to conclude that the rehabilitation of patients with untreated periodontitis using immediately loaded dental implants is feasible in the medium-term, when periodontal therapy is provided after rehabilitation and the patients are regularly maintained.
Cercadillo-Ibarguren, Iñaki; Sánchez-Torres, Alba; Figueiredo, Rui; Valmaseda-Castellón, Eduard
To describe the clinical outcomes and complications related to provisional prostheses after full-arch implant-supported rehabilitation by means of an immediate loading protocol. This retrospective cohort study included patients who were consecutively treated with full-arch implant-supported restorations with a minimum of four implants (Replace Select Tapered TiUnite, Nobel Biocare AB) per arch and conical abutments (multi-unit, Nobel Biocare AB) by means of an immediate loading protocol. The surgical procedures were performed between May 2006 and June 2014 by a single oral surgeon. Demographic, surgical, and prosthetic variables were collected, and biologic and mechanical complications were registered. A total of 61 maxillae (57%) and 46 mandibles (43%) were treated in 88 patients (40 men and 48 women) with a mean age of 62.4 years. A total of 558 implants were placed, 295 in postextraction sockets. A total of 331 implants (59.3%) were placed in the maxilla and 227 (40.7%) in the mandible. Within a 9-month period, 18 prostheses (16.8%) fractured (15 maxillary and 3 mandibular); in nine of these patients the opposing dentition was a full-arch, implant-supported restoration, and in the remaining nine patients, it was natural dentition. Six (1.1%) maxillary and three (0.5%) mandibular implants failed. A high implant survival rate is expected in the short term following this immediate loading protocol. Fracture of the provisional prosthesis is a common finding, affecting 17% of patients, and is significantly more prevalent in patients with bruxism and in maxillary prostheses.
Mundt, Torsten; Al Jaghsi, Ahmad; Schwahn, Bernd; Hilgert, Janina; Lucas, Christian; Biffar, Reiner; Schwahn, Christian; Heinemann, Friedhelm
2016-07-30
Acceptable short-term survival rates (>90 %) of mini-implants (diameter < 3.0 mm) are only documented for mandibular overdentures. Sound data for mini-implants as strategic abutments for a better retention of partial removable dental prosthesis (PRDP) are not available. The purpose of this study is to test the hypothesis that immediately loaded mini-implants show more bone loss and less success than strategic mini-implants with delayed loading. In this four-center (one university hospital, three dental practices in Germany), parallel-group, controlled clinical trial, which is cluster randomized on patient level, a total of 80 partially edentulous patients with unfavourable number and distribution of remaining abutment teeth in at least one jaw will receive supplementary min-implants to stabilize their PRDP. The mini-implant are either immediately loaded after implant placement (test group) or delayed after four months (control group). Follow-up of the patients will be performed for 36 months. The primary outcome is the radiographic bone level changes at implants. The secondary outcome is the implant success as a composite variable. Tertiary outcomes include clinical, subjective (quality of life, satisfaction, chewing ability) and dental or technical complications. Strategic implants under an existing PRDP are only documented for standard-diameter implants. Mini-implants could be a minimal invasive and low cost solution for this treatment modality. The trial is registered at Deutsches Register Klinischer Studien (German register of clinical trials) under DRKS-ID: DRKS00007589 ( www.germanctr.de ) on January 13(th), 2015.
Fuh, Lih-Jyh; Hsu, Jui-Ting; Huang, Heng-Li; Chen, Michael Y C; Shen, Yen-Wen
2013-01-01
Bone stress and interfacial sliding at the bone-implant interface (BII) were analyzed in zirconia and titanium implants with various thread designs and interface conditions (bonded BII and contact BIIs with different frictional coefficients) for both conventional and immediately loaded treatments. A total of 18 finite element models comprising two implant materials (zirconia and titanium), three thread designs (different shapes and pitches), and three interface conditions (bonded and contact BIIs) were analyzed to assess the effects on bone stresses and on sliding at the BII. The material properties of the bone model were anisotropic, and a lateral force of 130 N was applied as the loading condition. In the immediately loaded implant, the stress was highly concentrated at one site of the peri-implant bone. The peak bone stress was more than 20% lower in zirconia implants than in titanium implants for a bonded BII and 14% to 20% lower for a contact BII. The bone stresses did not differ significantly between implants with V-shaped threads and square threads. However, sliding at the BII was more than 25% lower with square-thread implants than with V-shaped-thread implants for titanium implants and 36% lower for zirconia implants. Reducing the thread size and pitch in cortical bone (via two V-shaped threads with different pitches) decreased the bone stress by 13%. Increasing the frictional coefficient reduced sliding at the BII in both zirconia and titanium implants. As an implant material, zirconia can reduce the bone stress in the crestal cortical region. Bone stress and sliding at the BII are heavily dependent on the thread design and the frictional coefficient at the BII of immediately loaded implants.
Ostman, Pär-Olov; Wennerberg, Ann; Albrektsson, Tomas
2010-03-01
Recently, a new implant surface texture, featuring application of nanometer-scale calcium phosphate has been shown to enhance early bone fixation and formation in preclinical studies and in human histomorphometric studies, which may be beneficial in immediate loading situations. The purpose of the present prospective clinical study was to, during 1 year, clinically and radiographically evaluate a nanometer scale surface modified implant placed for immediate loading of fixed prostheses in both maxillary and mandibular regions. Thirty-five out of 38 patients who needed implant treatment and met inclusion criteria agreed to participate in the study and were consecutively enrolled. Surgical implant placement requirements consisted of a final torque of a least 25 Ncm prior to final seating and an implant stability quotient above 55. A total of 102 NanoTite PREVAIL (NTP) implants (BIOMET 3i, Palm Beach Gardens, FL, USA) (66 maxillary and 36 mandibular) were placed by one investigator, and the majority of these were placed in posterior regions (65%) and in soft bone (69%). A total of 44 prosthetic constructions were evaluated consisting of 14 single-tooth restorations, 26 fixed partial dentures, and four complete fixed restorations. All provisional constructions were delivered within 1 hour, and the final constructions placed after 4 months. Implants were monitored for clinical and radiographic outcomes at follow-up examinations scheduled for 3, 6, and 12 months. Of the 102 study implants, one implant failed. The simple cumulative survival rate value at 1 year was 99.2%. The average marginal bone resorption was 0.37 mm (SD 0.39) during the first year in function. According to the success criteria of Albrektsson and Zarb, success grade 1 was found with 93% of the implants. Although limited to the short follow-up, immediate loading of NanoTite Prevail implants seems to be a viable option in implant rehabilitation, at least when a good initial fixation is achieved.
Błaszczyszyn, Artur; Kubasiewicz-Ross, Paweł; Gedrange, Tomasz; Dominiak, Marzena
2013-01-01
The paper presents clinical-radiological research on the impact of the new semi-cement luting agent in the immediately loaded implant-supported restoration on alveolar ridge resorption. 25 patients with a partially edentulous alveolar ridge in the anterior section of the maxilla or mandible were included in the study. The implants were inserted with the application of traditional burs or with a Piezosurgery device supplied by Mectron. Taking into account the method of implant bed preparation, the scientific material was divided into two groups. The implants were loaded immediately with single crown restorations cemented with the Implantlink semi cement application. The following indices were taken into consideration: pocket depth around implant calculated at four measuring points, marginal alveolar bone loss measured using radio-visiography, the 3-degree Wachtel scale of healing of the soft tissue. In addition, the presence and possible width or height of any recession around the implants was measured. The success of the implant treatment was assessed according to the Albrektsson success criteria. The research results were subjected to statistical analysis. The results of our study revealed no influence of the Implant-link semi cement on the crestal bone level, regardless of the bone bed preparation technique.
2015-01-01
PURPOSE In this study, a temporal abutment fixation screw, designed to fracture in a controlled way upon application of an occlusal force sufficient to produce critical micromotion was developed. The purpose of the screw was to protect the osseointegration of immediate loaded single implants. MATERIALS AND METHODS Seven different screw prototypes were examined by fixing titanium abutments to 112 Mozo-Grau external hexagon implants (MG Osseous®; Mozo-Grau, S.A., Valladolid, Spain). Fracture strength was tested at 30° in two subgroups per screw: one under dynamic loading and the other without prior dynamic loading. Dynamic loading was performed in a single-axis chewing simulator using 150,000 load cycles at 50 N. After normal distribution of obtained data was verified by Kolmogorov-Smirnov test, fracture resistance between samples submitted and not submitted to dynamic loading was compared by the use of Student's t-test. Comparison of fracture resistance among different screw designs was performed by the use of one-way analysis of variance. Confidence interval was set at 95%. RESULTS Fractures occurred in all screws, allowing easy retrieval. Screw Prototypes 2, 5 and 6 failed during dynamic loading and exhibited statistically significant differences from the other prototypes. CONCLUSION Prototypes 2, 5 and 6 may offer a useful protective mechanism during occlusal overload in immediate loaded implants. PMID:25932315
Gherlone, Enrico F.; Rapanelli, Andrea; Crespi, Roberto; Gastaldi, Giorgio
2018-01-01
Objectives The aim of this clinical study was to evaluate a new type of prefabricated bar system, supported by axial and tilted implants at 5-year follow-up. Materials and Methods Twenty-nine consecutive participants (19 females, 10 males) (mean age 61.4 years), edentulous in one or both jaws, with severe atrophy of the posterior regions, were treated according to the All-on-four® protocol with immediately loaded axial (64) and tilted (64) implants supporting complete-arch screw-retained prostheses (12 maxillary, 20 mandibular) featuring a prefabricated bar as framework. Follow-up visits were performed at 3, 6, 12, 24, 48, and 60 months after implant insertion. Radiographic assessments were made using panoramic radiographs obtained immediately after surgery and at each follow-up visit. Bone level measurements around the axial and tilted implants were compared by means of the Student's t-test. Results One axial implant failed in the lower jaw and did not compromise prosthetic function. The 60-month overall implant survival rate was 100% for axially positioned implants and 98.44% for tilted implants. The implant survival rates were 100% in the maxilla and 98.75% in the mandible. None of the 32 fixed prostheses were lost during the observation period, representing a prosthetic survival rate of 100%. No statistically significant differences (P > 0.05) in marginal bone loss between tilted and axial implants were detected in either jaw over time. Conclusions The use of the evaluated prefabricated bar for immediately loaded implants placed according to the All-on-four concept may significantly reduce implant failures; however, more long-term prospective clinical trials are needed to affirm the effectiveness of the surgical-prosthetic protocol. PMID:29682552
Soliman, Mahitab M.; Zaki, Azza Abdulrahman; El Gazaerly, Hanaa Mohamed; Shemmrani, Ammar Al; Sorour, Abd El Latif
2014-01-01
Objective This study was conducted to evaluate clinically and radiographically the use of a cellular dermal matrix allograft (Alloderm) in combination with PLA/PGA (Fisiograft) around immediate implants. Materials and Methods Fourteen patients were included in this study, three patients received two implants, total of seventeen implants were placed. Periapical radiographs and orthopantomographs were taken. The selected teeth were extracted atraumatically after the reflection of full thickness flaps. One-piece Zimmer implants were placed immediately into the sockets. Weeks from implantation, radiographic evaluation was made at 6 Fisiograft in powder form was placed in the osseous defects around the implants. The implants were immediately restored with provisional crowns free from occlusion. Patients were clinically evaluated at 3, 6, and 14 months after loading which was done after 6 weeks from implantation. Radiographic evaluation was made at 6 and 14 months from implant placement. Results showed that immediate implantation was successful in sixteen out of seventeen implants, clinical parameters regarding plaque index, gingival index, there was a slight decrease through the follow-up periods from 3 to 14 months but it was non-significant, while there was a significant decrease in the probing depth. Radiographically there was a significant increase in the bone density from 6 to 14 months post loading, while the vertical bone defect was significantly decreased. The fisiograft functioned well as space maker and scaffolding material. The Alloderm performed well as a membrane to be used in association with immediate implants and it has a good potentiality for increasing the width of the keratinized gingiva, which is an important feature for implant esthetics. Conclusion the combination technique between the bone graft and the membrane proved to be successful to overcome dehiscence and osseous defects around immediate implants. PMID:25780357
Zygomatic implant-retained fixed complete denture for an elderly patient.
Baig, Mirza Rustum; Rajan, Gunaseelan; Yunus, Norsiah
2012-06-01
Dental rehabilitation of a completely edentulous geriatric patient has always been a challenge to the clinician, especially in treating those with higher expectations and demands. Treatment duration and the amount of residual alveolar bone available are often important considerations when planning for dental implant-based fixed treatment for these patients. With the introduction of zygomatic implants, a graftless alternative solution has emerged for deficient maxillary bone with provision for immediate loading. This article describes the treatment of a completely edentulous elderly patient using zygomatic implants in conjunction with conventional implants. The implants were immediately loaded using a definitive acrylic resin fixed denture reinforced with a cast metal framework, to provide function and aesthetics. © 2011 The Gerodontology Society and John Wiley & Sons A/S.
2017-01-01
Purpose The possibility of immediate or early loading has become popular in implant dentistry. A prerequisite for the immediate or early loading of an implant prosthesis is the achievement of initial stability in the implant. Moreover, in response to clinicians' interest in verifying clinical stability to determine the optimal time point for functional loading, a non-invasive method to assess implant stability has been developed on the basis of resonance frequency analysis (RFA). The primary objective of this study was to monitor the stability of sandblasted, large-grit, and acid-etched (SLA) implants with different diameters during the early phases of healing by RFA. The secondary objective was to evaluate how the initial stability of implants varied depending on different surface modifications and other contributing factors. Methods Thirty-five implants (25 SLA implants and 10 resorbable blasting media [RBM] implants) placed in 20 subjects were included. To measure implant stability, RFA was performed at baseline and at 1, 2, 3, 4, 6, and 10 weeks after surgery. Results The longitudinal changes in the implant stability quotient (ISQ) values were similar for the SLA implants with different diameters and for the RBM implants. During the initial healing period, the ISQ decreased after installation and reached its lowest values at 1 week and 2 weeks, respectively. The mean ISQ values in the SLA implants were significantly higher in Ø 5.0 mm implants than in Ø 4.0 mm implants. Men showed a higher ISQ than women. Mandibular sites showed a higher ISQ than maxillary sites. Conclusions All implants used in this study are suitable for immediate or early loading under appropriate indications. A wider diameter and SLA surface treatment of implants could improve the stability, if the implant is fixed with at least 30 Ncm of insertion torque. PMID:28462009
Trisi, Paolo; De Benedittis, Simona; Perfetti, Giorgio; Berardi, Davide
2011-05-01
Protocols of immediate loading have been reported in several studies. It has also been demonstrated that the cause of failure of immediate loaded implants is due to the micromotion on the bone-implant interface induced by immediate loading. There should be a minimum gap between the implant and the peri-implant bone, without micromotions occurring above a definite threshold risk as they induce bone resorption and fibrosis around the implant. Measurement of the torque necessary to insert an implant in the bone is a parameter for measuring initial stability. The higher the implant insertion torque, the higher the initial stability attained. The aim of this study was to evaluate in vitro the correlation between the micromotion of cylindric screw implants ad modum Branemark and the insertion torque in bone of different densities. The test was carried out on 2 × 2 cm samples of fresh bovine bone of three different densities: hard (H), medium (M) and soft (S). One hundred and fifty hexa implants ad modum Branemark were used, 3.75 mm in diameter and 9 mm long. To screw in the implants, a customized manual key was used, controlled digitally to evaluate the peak insertion torques. Ten implants were prepared for each torque (20, 35, 45, 70 and 100 N/cm). The bone sample was then fixed on a loading device, which allowed evaluating the micromotion. On each sample, we applied a 25 N horizontal force. The results indicate that the peak insertion torque and the implant micromotion are statistically correlated, and statistically significant differences in H and M bone were found compared with S bone. In S bone, we noted a micromotion significantly higher than the risk threshold, and it was not possible to reach peak insertion torque above 35 N/cm. In H and M bone, the micromotion is below the threshold of all insertion torques. Increasing the peak insertion torque, we can reduce the extent of the micromotion between the implant and the bone when submitted to lateral forces in vitro. In soft bone, the micromotion was always high; hence, immediate loading of implants in low-density bone should be evaluated with care. © 2010 John Wiley & Sons A/S.
Biomechanics and strain mapping in bone as related to immediately-loaded dental implants
Du, Jing; Lee, Jihyun; Jang, Andrew; Gu, Allen; Hossaini-Zadeh, Mehran; Prevost, Richard; Curtis, Don; Ho, Sunita
2015-01-01
The effects of alveolar bone socket geometry and bone-implant contact on implant biomechanics, and resulting strain distributions in bone were investigated. Following extraction of lateral incisors on a cadaver mandible, immediate implants were placed and bone-implant contact area, stability and bone strain were measured. In situ biomechanical testing coupled with micro X-ray microscope (μ-XRM) illustrated less stiff bone-implant complexes (701-822 N/mm) compared with bone-periodontal ligament (PDL)-tooth complexes (791-913 N/mm). X-ray tomograms illustrated that the cause of reduced stiffness was due to reduced and limited bone-implant contact. Heterogeneous elemental composition of bone was identified by using energy dispersive X-ray spectroscopy (EDS). The novel aspect of this study was the application of a new experimental mechanics method, that is, digital volume correlation, which allowed mapping of strains in volumes of alveolar bone in contact with a loaded implant. The identified surface and subsurface strain concentrations were a manifestation of load transferred to bone through bone-implant contact based on bone-implant geometry, quality of bone, implant placement, and implant design. 3D strain mapping indicated that strain concentrations are not exclusive to the bone-implant contact regions, but also extend into bone not directly in contact with the implant. The implications of the observed strain concentrations are discussed in the context of mechanobiology. Although a plausible explanation of surgical complications for immediate implant treatment is provided, extrapolation of results is only warranted by future systematic studies on more cadaver specimens and/or in vivo small scale animal models. PMID:26162549
Ostman, Pär-Olov; Hellman, Mats; Sennerby, Lars; Wennerberg, Ann
2008-05-01
During the last years, focus has been paid to implant treatment using immediate function protocols, and different approaches to provide patients with temporary constructions have been presented. Most of these techniques involve dental technicians producing the temporary construction, for example, rebuilding existing dentures, acrylic bridges, etc. The purpose of this prospective clinical study was to evaluate the clinical outcome of a chair-side technique of a cost-effective temporary prosthesis. Fixture survival rate and risk of temporary bridge failure were analyzed. Thirty-seven partially or totally edentate patients (18 female and 19 male; mean age: 66.7 years) treated with chair-side manufactured temporary restorations (QuickBridge, BIOMET 3i, Palm Beach, Fl, USA) for immediate loading have been evaluated. The prostheses extended from two unit bridges supported by two implants to full-arch construction supported by six implants. The temporary prostheses were monitored from the day of surgery and delivery to the time of replacement with a permanent prosthetic construction 3 to 6 months later. No implants were lost during the observation time. One (3%) temporary prosthesis fractured and additional two (6%) loosened during the follow-up time. The study indicated that the tested chair-side concept for manufacturing of temporary prosthesis for immediate loading of dental implants is a viable approach.
Chambrone, Leandro; Shibli, Jamil Awad; Mercúrio, Carlos Eduardo; Cardoso, Bruna; Preshaw, Philip M
2015-04-01
To assess the survival percentage, clinical and radiographic outcomes of sandblasted and acid-etched (SLA) dental implants and its modified surface (SLActive) in protocols involving immediate and early occlusal loading. MEDLINE, EMBASE and the Cochrane Oral Health Group's Trials Register CENTRAL were searched in duplicate up to, and including, June 2013 to include randomised controlled trials (RCTs) and prospective observational studies of at least 6-month duration published in all languages. Studies limited to patients treated with SLA and/or SLActive implants involving a treatment protocol describing immediate and early loading of these implants were eligible for inclusion. Data on clinical and/or radiographic outcomes following implant placement were considered for inclusion. Of the 447 potentially eligible publications identified by the search strategy, seven RCTs comprising a total of 853 implants (8% titanium plasma-sprayed, 41.5% SLA and 50.5% SLActive) and 12 prospective observational studies including 1394 SLA and 145 SLActive implants were included in this review. According to the Cochrane Collaboration's tool for assessing risk of bias, one of the studies was considered to be at a low risk of bias, whereas the remaining studies were considered to be at an unclear risk. Regarding the observational studies, all of them presented a medium methodological quality based on the Modified Newcastle-Ottawa scale. There were no significant differences reported in the studies in relation to implant loss or clinical parameters between the immediate/early loading and delayed loading protocols. Overall, 95% of SLA and 97% of SLActive implants still survive at the end of follow-up. Despite of the positive findings achieved by the included studies, few RCTs were available for analysis for SLActive implants. Study heterogeneity, scarcity of data and the lack of pooled estimates represent a limitation between studies' comparisons and should be considered when interpreting the present findings. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Dolz, Javier; Silvestre, Francisco J; Montero, Javier
2014-01-01
To evaluate changes in the general and oral health-related quality of life (using the European Quality of Life indicator and the Oral Health Impact Profile-49 [OHIP-49], respectively) of patients treated with conventionally or immediately loaded implants. This clinical trial consisted of a clinical oral examination and a questionnaire-based interview carried out before and after both surgery and definitive prosthetic rehabilitation in a consecutive sample of patients requiring dental implants. According to the clinical diagnosis and patient preference, patients were assigned to the immediate loading group (IL group; n = 29) or the conventional loading group (CL group; n = 75). The change summary scores and effect sizes were calculated in the intermediate stage and at the final follow-up, taking baseline scores as reference. The oral health-related quality of life and oral satisfaction after implant therapy were significantly better than at baseline, with an even greater benefit when the implants were loaded immediately than when prosthetic rehabilitation was delayed. However, there were no significant differences in between-group comparisons in the ratings of general health status. The effect size for the OHIP-49 exceeded the threshold value of 0.8 for the domains functional limitation, pain/discomfort, and psychological discomfort in both groups and also for physical disability and psychological disability in the IL group. A gradual improvement in oral well-being scores, but not in those of general well-being, were observed for both groups from the intermediate stage to the final evaluation. This benefit was markedly greater for the IL group.
Villa, Max M; Wang, Liping; Rowe, David W; Wei, Mei
2014-01-01
Cell-based tissue engineering can be used to replace missing or damaged bone, but the optimal methods for delivering therapeutic cells to a bony defect have not yet been established. Using transgenic reporter cells as a donor source, two different collagen-hydroxyapatite (HA) scaffolds, and a critical-size calvarial defect model, we investigated the effect of a cell-attachment period prior to implantation, with or without an extracellular matrix-based seeding suspension, on cell engraftment and osteogenesis. When quantitatively compared, the in-house scaffold implanted immediately had a higher mean radiopacity than in-house scaffolds incubated overnight. Both scaffold types implanted immediately had significantly higher area fractions of donor cells, while the in-house collagen-HA scaffolds implanted immediately had higher area fractions of the mineralization label compared with groups incubated overnight. When the cell loading was compared in vitro for each delivery method using the in-house scaffold, immediate loading led to higher numbers of delivered cells. Immediate loading may be preferable in order to ensure robust bone formation in vivo. The use of a secondary ECM carrier improved the distribution of donor cells only when a pre-attachment period was applied. These results have improved our understanding of cell delivery to bony defects in the context of in vivo outcomes.
Jayme, Sérgio J; Muglia, Valdir A; de Oliveira, Rafael R; Novaes, Arthur B Júnior
2008-01-01
Immediate loading of dental implants shortens the treatment time and makes it possible to give the patient an esthetic appearance throughout the treatment period. Placement of dental implants requires precise planning that accounts for anatomic limitations and restorative goals. Diagnosis can be made with the assistance of computerized tomographic scanning, but transfer of planning to the surgical field is limited. Recently, novel CAD/CAM techniques such as stereolithographic rapid prototyping have been developed to build surgical guides in an attempt to improve precision of implant placement. The aim of this case report was to show a modified surgical template used throughout implant placement as an alternative to a conventional surgical guide.
Kronstrom, Mats; Davis, Ben; Loney, Robert; Gerrow, Jack; Hollender, Lars
The purpose of this study was to evaluate patient satisfaction and clinical outcomes among subjects with mandibular overdentures supported by one or two immediately placed dental implants 5 years after loading. Thirty-six subjects (16 men and 20 women) received one or two dental implants in the anterior mandible, and all implants were loaded the day of surgery. Subjects were scheduled for follow-up 3-, 6-, and 12 months after implant placement and thereafter annually for 4 more years. Patient satisfaction scores were measured with the Oral Health Impact Profile-EDENT (OHIPEDENT) questionnaire. Seventeen subjects (7 male and 10 female) with a mean age of 59.4 years (range, 44 to 74 years) were available for the 5-year follow-up examination. Nine subjects with 10 failing implants were excluded during the first year and nine subjects were lost to follow-up. No implants failed between the 12- and 60-month follow-up examinations, and the need for denture maintenance was low. Mean peri-implant bone change was 0.92 mm, and the Spearman test failed to show correlation between the insertion torque value and implant stability quotient. Patient satisfaction scores increased significantly when compared with baseline values and continued to be high for both groups, with no significant differences. Ten implants in nine subjects failed early, but no failures were observed after the 12-month examination. No significant differences were found between subjects in the two groups with respect to implant survival rates and peri-implant bone loss, and patient satisfaction scores continued to be high. Although patient satisfaction and implant success were high during the 12- to 60-month period, the results should be interpreted with caution because of the high number of failing implants and patients lost to follow-up. More research is needed to study outcomes of treatment with immediately loaded mandibular implant overdentures.
Mondani intraoral welding: historical process and main practical applications.
Dal Carlo, L; Pasqualini, M E; Mondani, P M; Rossi, F; Moglioni, E; Shulman, M
2017-01-01
The intraoral welder was invented by Dr. Pierluigi Mondani during the early 70s to weld titanium needle implants to a titanium bar in patients mouth and to load them immediately by means of resin prosthesis. The clinical use documented dates back to 1972. Over the years, many practical applications have been added to the initial one, which have expanded the use of this device. In this scientific work, main applications are described. The aim of the work was to trace the historical process of intra-oral welding according to Mondani and describe the main practical applications. Intra-oral welding is a process introduced by dr. Pier Luigi Mondani of Genova (Italy) which allows to firmly conjoin titanium implants of any shape by means of a titanium bar or also directly between them in the mouth during surgery. The immediate stabilization achieved by intraoral welding increases implants success rate, allows immediate loading even in situations of bone atrophy, saves implants that are running into failure, re-evaluates fractured implants, allows to stabilize submerged implants postponing prosthesis management, allows to achieve efficient rehabilitation protocols to deal with difficult cases. The 40-years experience with intra-oral welding described in this article, confirms the ease of use and efficiency in providing immediate stabilization of titanium implants of all types.
Cehreli, Secil; Yilmaz, Alev; Arman-Ozcirpici, Ayca
2013-04-01
To measure strains around orthodontic implants upon torque tightening and loading and to assess correlations between factors influencing primary stability. Self-drilling implants were placed into bovine iliac crest blocks after CT assessments. Upon bonding of strain gauges on bone adjacent to the implants, strain measurements were performed using a data acquisition system during torque tightening and 250 g orthodontic force application by elastic chains. The torque required to place straight implants (12.16 N.cm) was higher than 30- to 40-degree angulated implants (9.31 N.cm) (P < 0.05). Cortical bone strain amplitudes of both implant placements were comparable (P > 0.05). Strains during torque tightening of straight (196 με) and tilted (114 με) implants were higher than those obtained during orthodontic loading (20-30 με). Despite the positive and direct relationship found between torque and torque strain output, strong correlations between other parameters could not be detected. Vertically aligned and 30- to 40-degree angulated immediate orthodontic microimplants are associated with low amplitude strains upon torque tightening and orthodontic loading.
Chen, Jianyu; Zhang, Zhiguang; Chen, Xianshuai; Zhang, Xiao
2017-05-01
Due to the increasing adoption of immediate implantation strategies and the rapid development of the computer aided design/computer aided manufacturing technology, a therapeutic concept based on patient-specific implant dentistry has recently been reintroduced by many researchers. However, little information is available on the designs of custom-made dental implant systems, especially their biomechanical behavior. The influence of the custom-made implant designs on the biomechanical performance for both an immediate and a delayed loading protocol in the maxillary esthetic zone was evaluated by means of the finite element (FE) method. FE models of three dental implants were considered: a state of the art cylindrical implant and two custom-made implants designed by reverse engineering technology, namely a root-analogue implant and a root-analogue threaded implant. The von Mises stress distributions and micro-motions around the bone-implant interfaces were calculated using ANSYS software. In a comparison of the three implant designs for both loading protocols, a favorable biomechanical performance was observed for the use of root-analogue threaded implant which approximated the geometry of natural anterior tooth and maintained the original long-axis. The results indicated that bone-implant interfacial micro-motion was reduced and a favorable stress distribution after osseointegration was achieved.
Hasturk, Hatice; Kantarci, Alpdogan; Ghattas, Mazen; Schmidt, Marcella; Giordano, Russell A.; Ashman, Arthur; Diekwisch, Thomas G.; Van Dyke, Thomas
2015-01-01
Background The present study is designed as a proof-of-concept study to evaluate light/chemical hardening technology and a newly formulated polymethylmethacrylate, polyhydroxyethylmethacrylate, and calcium hydroxide (PPCH) plus polyanhydride (PA) (PPCH-PA) composite graft material as a bone substitute compared to positive and negative controls in a minipig model. Methods PPCH-PA (composite graft); PPCH alone (positive control), PA alone (positive control), and no graft (negative control) were compared. Four mandibular premolar teeth per quadrant were extracted; a total of 48 implants were placed into sockets in three minipigs. Abutments were placed protruding into the oral cavity 4 mm in height for immediate loading. Crestal areas and intrabony spaces were filled with PPCH-PA, PPCH, or PA using a three-phase delivery system in which all graft materials were hardened by a light cure. In the negative control group, implant sites were left untreated. At 12 weeks, block sections containing implants were obtained. Evaluations included periodontal probing, pullout-force load, and stability measurements to determine implant stability, radiographs to examine bone levels, and scanning electron microscopy (SEM)–energy-dispersed spectroscopy to determine bone-to-implant contact. Results Probing measurements did not reveal any pathologic pocket formation or bone loss. Radiographs revealed that immediate implant placement and loading resulted in bone at or slightly apical to the first thread of the implant in all groups at 12 weeks. Stability test values showed a relative clinical stability for all implants (range: −7 to +1); however, implants augmented with PPCH-PA exhibited a statistically significantly greater stability compared to all other groups (P <0.05). The newly formed bone in PPCH-PA–treated sites was well organized with less marrow spaces and well-distributed osteocytes. SEM revealed a tighter implant–socket interface in the PPCH-PA group compared to other groups with reduced microfissures and implant–bone interface fractures during pullout testing, whereas implants treated with PA or no graft showed ≈10-μm microfissures between the implant and bone with fractures of the intrathread bone. Conclusions The newly formulated chemically hardened graft material PPCH-PA was useful in immediate implant placement after tooth extraction and resulted in greater stability and a well-organized implant–bone interface with immediate loading, especially in those areas where cancellous bone was present. The results of this proof-of-concept study warranted further research investigating different healing times and longer durations. PMID:21342001
Zuffetti, Francesco; Esposito, Marco; Capelli, Matteo; Galli, Fabio; Testori, Tiziano; Del Fabbro, Massimo
2013-01-01
To evaluate whether grafting with additional anorganic bovine bone to augment horizontally the buccal plate (internal and external grafting [IEG]) at single post-extractive implants preserves the alveolar ridge, improving aesthetics, better than internal socket grafting alone (ISGA). A total of 78 patients, treated in four Italian private practices, requiring a single immediate post-extractive implant, having at least 1 mm of implant-to-buccal bone gap after implant insertion and a preserved buccal bone, had the residual bone-to-implant gap filled with anorganic bovine bone. Thirty-nine randomly allocated patients received additional buccal horizontal augmentation of about 2 mm thickness with the same bone substitute (IEG group) covered with collagen resorbable membranes. Implants were submerged for 4 months before being loaded with provisional acrylic crowns. Definitive crowns were delivered after 6 months. Outcome measures were crown/implant failures, complications and aesthetics recorded by blinded assessors 6 months after initial loading, at delivery of definitive crowns. Six months after initial loading, 8 patients dropped out, did not complete the treatment or were treated twice and therefore had to be excluded (4 from each group). There were no statistically significant differences for implant failures and complications between the two groups. Two implants failed in the IEG group versus 1 in the ISGA group. Four complications occurred, 2 in each group. The mean implant aesthetic score (IAS) was 7.8 at ISGA sites and 8.0 at IEG sites. There were no statistically significant differences between the two groups (P = 0.492; difference 0.2 mm; 95% CI -0.769, 0.369) for IAS score. There were no statistically significant differences in the outcomes between the centres. The use of adjunctive anorganic bovine bone placed buccally at preserved buccal sites of immediate post-extractive implants may not improve the aesthetic outcome, however additional research is needed to confirm or reject these preliminary findings.
Micromotion and stress distribution of immediate loaded implants: a finite element analysis.
Fazel, A; Aalai, S; Rismanchian, M; Sadr-Eshkevari, P
2009-12-01
Primary stability and micromotion of the implant fixture is mostly influenced by its macrodesign. To assess and compare the peri-implant stress distribution and micromotion of two types of immediate loading implants, immediate loaded screw (ILS) Nisastan and Xive (DENTSPLY/Friadent, Monnheim, Germany), and to determine the best macrodesign of these two implants by finite element analysis. In this experimental study, the accurate pictures of two fixtures (ILS: height = 13, diameter = 4 mm and Xive: height = 13, diameter = 3.8 mm) were taken by a new digital camera (Nikon Coolpix 5700 [Nikon, Japan], resolution = 5.24 megapixel, lens = 8x optical, 4x digital zoom). Following accurate measurements, the three-dimensional finite element computer model was simulated and inserted in simulated mandibular bone (D(2)) in SolidWorks 2003 (SolidWork Corp., MA, USA) and Ansys 7.1 (Ansys, Inc., Canonsburg, PA, USA). After loading (500 N, 75 degrees above horizon), the displacement was displayed and von Mises stress was recorded. It was found that the primary stability of ILS was greater (152 microm) than Xive (284 microm). ILS exhibited more favorable stress distribution. Maximum stress concentration found in periapical bone around Xive ( approximately 30 MPa) was lesser than Nisastan ( approximately 37 MPa). Macrodesign of ILS leads to better primary stability and stress distribution. Maximum stress around Xive was less.
Osseous adaptation to continuous loading of rigid endosseous implants
NASA Technical Reports Server (NTRS)
Roberts, W. E.; Smith, R. K.; Mozsary, P. G.; Zilberman, Y.; Smith, R. S.
1984-01-01
The effect of loading on etched Ti implants in the femurs of young (3 mo) and adult (6 mo) rabbits is investigated experimentally. The results are presented in photographs, fluorescence and polarization micrographs, radiographs, and drawings and discussed. Implantation is followed by formation of coarse woven bone within 3 d and mature lamellar bone by 6 wks, with nonspecific subperiosteal bony hypertrophy in the young rabbits only. Spring loading at 100 g produces spontaneous spiral-type fractures when applied immediately, but the implants remain rigid when loads are applied after 6-12 wks of healing. The mechanisms of bone formation involved are examined, and the potential of endosseous implants as anchors in orthodontics or dentofacial-orthopedics is confirmed.
Pera, F; Pesce, P; Solimano, F; Tealdo, T; Pera, P; Menini, M
2017-05-01
Frameworks made of carbon fibre-reinforced composites (CFRC) seem to be a viable alternative to traditional metal frameworks in implant prosthodontics. CFRC provide stiffness, rigidity and optimal biocompatibility. The aim of the present prospective study was to compare carbon fibre frameworks versus metal frameworks used to rigidly splint implants in full-arch immediate loading rehabilitations. Forty-two patients (test group) were rehabilitated with full-arch immediate loading rehabilitations of the upper jaw (total: 170 implants) following the Columbus Bridge Protocol with four to six implants with distal tilted implants. All patients were treated with resin screw-retained full-arch prostheses endowed with carbon fibre frameworks. The mean follow-up was 22 months (range: 18-24). Differences in the absolute change of bone resorption over time between the two implant sides (mesial and distal) were assessed performing a Mann-Whitney U-test. The outcomes were statistically compared with those of patients rehabilitated following the same protocol but using metal frameworks (control group: 34 patients with 163 implants - data reported in Tealdo, Menini, Bevilacqua, Pera, Pesce, Signori, Pera, Int J Prosthodont, 27, 2014, 207). Ten implants failed in the control group (6·1%); none failed in the test group (P = 0·002). A statistically significant difference in the absolute change of bone resorption around the implants was found between the two groups (P = 0·004), with greater mean peri-implant bone resorption in the control group (1 mm) compared to the test group (0·8 mm). Carbon fibre frameworks may be considered as a viable alternative to the metal ones and showed less marginal bone loss around implants and a greater implant survival rate during the observation period. © 2017 John Wiley & Sons Ltd.
Immediate esthetic crown with a facet of the extracted element
Di Giacomo, Giovanni de Almeida Prado; Magalhães, Amanda; Ajzen, Sergio
2014-01-01
The present report describes a case of implant loading with an immediate temporary crown. The buccal crown surface was removed from the extracted tooth to obtain an aesthetically satisfactory result. After periodontal treatment, tooth 21 appeared proclined and showed Grade 3 mobility, indicating the need for its extraction. The remaining bone was imaged using computed tomography, and virtual surgical planning was performed using these results. The implant was immediately loaded postextraction into the fresh alveolus without a graft and flap procedure. The temporary tooth, which was manufactured using the extracted buccal surface, was a simple, fast, and low cost procedure that produced an excellent esthetic outcome. PMID:25202225
SPINELLI, D.; DE VICO, G.; SCHIAVETTI, R.; BONINO, M.; POZZI, A.; BOLLERO, P.; BARLATTANI, A.
2010-01-01
SUMMARY The severe atrophy of the jaws are a challenging therapeutic problem, since the increase in bone is necessary to allow the placement of a sufficient number of implants. Combining immediate functionalization with the concept of guided surgery they combine the advantages offered by the innovative surgical and prosthetic implant technique (All-on-Four®) with those of computer-assisted planning in cases of severe bone atrophy. The method used in this case report, combines these two concepts in a surgical and prosthetic protocol safe and effective for the immediate function of 4 implants to support a fixed prosthesis in completely edentulous subjects. The integration of technology with immediate function with the concept of computer-guided surgery for implant placement and rehabilitation of completely edentulous jaws is now a predictable treatment modality with implant survival comparable to the traditional protocols. PMID:23285381
The role of single immediate loading implant in long Class IV Kennedy mandibular partial denture.
Mohamed, Gehan F; El Sawy, Amal A
2012-10-01
The treatment of long-span Kennedy class IV considers a prosthodontic challenge. This study evaluated the integrity of principle abutments in long Kennedy class IV clinically and radiographically, when rehabilitated with conventional metallic partial denture as a control group and mandibular partial overdentures supported with single immediately loaded implant in symphyseal as a study group. Twelve male patients were divided randomly allotted into two equal groups. First group patients received removable metallic partial denture, whereas in the second group, patients received partial overdentures supported with single immediately loaded implant in symphyseal region. The partial dentures design in both groups was the same. Long-cone paralleling technique and transmission densitometer were used at the time of denture insertion, 3, 6, and 12 months. Gingival index, bone loss, and optical density were measured for principle abutments during the follow-up. A significant reduction in bone loss and density were detected in group II comparing with group I. Gingival index had no significant change (p-value < 0.05). A single symphyseal implant in long span class IV Kennedy can play a pivotal role to improve the integrity of the principle abutments and alveolar bone support. © 2010 Wiley Periodicals, Inc.
De Santis, Daniele; Canton, Luciano Claudio; Cucchi, Alessandro; Zanotti, Guglielmo; Pistoia, Enrico; Nocini, Pier Francesco
2010-01-01
Computer-assisted surgery is based on computerized tomography (CT) scan technology to plan the placement of dental implants and a computer-aided design/computer-aided manufacturing (CAD-CAM) technology to create a custom surgical template. It provides guidance for insertion implants after analysis of existing alveolar bone and planning of implant position, which can be immediately loaded, therefore achieving esthetic and functional results in a surgical stage. The absence of guidelines to treat dentulous areas is often due to a lack of computer-assisted surgery. The authors have attempted to use this surgical methodology to replace residual teeth with an immediate implantoprosthetic restoration. The aim of this case report is to show the possibility of treating a dentulous patient by applying a computer-assisted surgical protocol associated with the use of a double surgical template: one before extraction and a second one after extraction of selected teeth.
Osseointegration of dental implants in Macaca fascicularis
NASA Astrophysics Data System (ADS)
Dewi, R. S.; Odang, R. W.; Odelia, L.
2017-08-01
Osseointegration is an important factor in determining the success of a dental implant. It can be assessed from the osseointegration that occurs between the implant and the bone. The implant stability is determined by the osseous support at the implant-bone interface, which is commonly evaluated by histomorphometric analysis. This study aimed to evaluate whether the osseointegration level measured by a Low Resonance Frequency Analyzer (LRFA) gave results as good as those obtained by histomorphometric examination. Six male Macaca fascicularis were used in this study. In each animal, two types of loading were performed: immediate and delayed loading. Clinical examination and LRFA measurement were performed to determine osseointegration at the first and second weeks and at the first, second, third, and fourth months. After four months, histomorphometric examination was performed. The relationship between the histomorphometric examination and LRFA measurement was compared using the Pearson correlation coefficient. There was no significant difference in the osseointegration between immediate loading and delayed loading (p > 0.05) The bone-implant contact percentage in the first group did not differ significantly from that in the second group. Statistical analysis showed that there was a strong correlation between LRFA measurement and histomorphometric examination. Osseointegration could be evaluated through LRFA measurement as well as through histomorphometric examination.
Yan, Qi; Xiao, Li-Qun; Su, Mei-Ying; Mei, Yan; Shi, Bin
This systematic review aimed to compare immediate protocols with conventional protocols of single-tooth implants in terms of changes in the surrounding hard and soft tissue in the esthetic area. Electronic and manual searches were performed in PubMed, EMBASE, Cochrane, and other data systems for research articles published between January 2001 and December 2014. Only randomized controlled trials (RCTs) reporting on hard and or soft tissue characteristics following a single-tooth implant were included. Based on the protocol used in each study, the included studies were categorized into three groups to assess the relationships between the factors and related esthetic indexes. Variables such as marginal bone level changes (mesial, distal, and mean bone level), peri-implant soft tissue changes (papilla level, midbuccal mucosa, and probing depth), and other esthetic indices were taken into consideration. The data were analyzed using RevMan version 5.3, Stata 12, and GRADEpro 3.6.1 software. A total of 13 RCTs met the inclusion criteria. Four studies examined immediate implant placement, five studies examined immediate implant restoration, and four studies examined immediate loading. Comparing the bone level changes following immediate and conventional restoration, no significant differences were found in the bone level of the mesial site (standard mean difference [SMD] = -0.04 mm; 95% confidence interval [CI]: -0.25 to 0.17 mm), the distal site (SMD = -0.15 mm; 95% CI: -0.38 to 0.09 mm), and the mean bone level changes (SMD = 0.05 mm; 95% CI: -0.18 to 0.27 mm). The difference in the marginal bone level changes between immediate and conventional loading was also not statistically significant (SMD = -0.05 mm; 95% CI: -0.15 to 0.06 mm for the mesial site and SMD = -0.02 mm; 95% CI: -0.09 to 0.05 mm for the distal site). Soft tissue changes following immediate and conventional restoration reported no significant differences in the papillae level of the mesial site (SMD = 0.18 mm; 95% CI: -0.00 to 0.37 mm), the papillae level of the distal site (SMD = -0.12 mm; 95% CI: -0.34 to 0.09 mm), and the midbuccal mucosa (SMD = -0.22 mm; 95% CI: -1.29 to 0.85 mm). Within the limitations, it can be concluded that immediately placed, restored, or loaded single-tooth implants in the esthetic zone result in similar hard and soft tissue changes compared with conventional protocols.
Bahrami, Babak; Shahrbaf, Shirin; Mirzakouchaki, Behnam; Ghalichi, Farzan; Ashtiani, Mohammed; Martin, Nicolas
2014-04-01
To investigate, by means of FE analysis, the effect of surface roughness treatments on the distribution of stresses at the bone-implant interface in immediately loaded mandibular implants. An accurate, high resolution, digital replica model of bone structure (cortical and trabecular components) supporting an implant was created using CT scan data and image processing software (Mimics 13.1; Materialize, Leuven, Belgium). An anatomically accurate 3D model of a mandibular-implant complex was created using a professional 3D-CAD modeller (SolidWorks, DassaultSystèmes Solid Works Corp; 2011). Finite element models were created with one of the four roughness treatments on the implant fixture surface. Of these, three were surface treated to create a uniform coating determined by the coefficient of friction (μ); these were either (1) plasma sprayed or porous-beaded (μ=1.0), (2) sandblasted (μ=0.68) or (3) polished (μ=0.4). The fourth implant had a novel two-part surface roughness consisting of a coronal polished component (μ=0.4) interfacing with the cortical bone, and a body plasma treated surface component (μ=1) interfacing with the trabecular bone. Finite element stress analysis was carried out under vertical and lateral forces. This investigation showed that the type of surface treatment on the implant fixture affects the stress at the bone-implant interface of an immediately loaded implant complex. Von Mises stress data showed that the two-part surface treatment created the better stress distribution at the implant-bone interface. The results from this FE computational analysis suggest that the proposed two-part surface treatment for IL implants creates lower stresses than single uniform treatments at the bone-implant interface, which might decrease peri-implant bone loss. Future investigations should focus on mechanical and clinical validation of these FE results. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Elsyad, Moustafa Abdou; Khirallah, Ahmed Samir
2016-11-01
Circumferential marginal bone around 2 splinted and nonsplinted immediately loaded implants in the edentulous mandible has not been previously investigated. The purpose of this randomized controlled clinical trial was to assess circumferential bone loss around splinted and nonsplinted immediately loaded implants retaining mandibular overdentures, using cone beam computed tomography (CBCT). Thirty participants with complete edentulism were allocated to 2 groups and received 2 implants in the canine region of the mandible. Implants were either left nonsplinted (with ball attachment [BA]) or splinted (with bar attachment [RA]). Mandibular overdentures were connected to the implants 1 week later. CBCT was used to evaluate vertical bone loss (VBL) and horizontal bone loss (HBLo) bone loss at the distal (D), buccal (B), mesial (M), and lingual (L) sites of each implant upon overdenture insertion (baseline, T0), 1 year (T1) and 3 years (T3) after insertion. Repeated measures ANOVA was used for statistical analysis (α=.05). No significant difference in the survival rate (93.3% for BA and 100% for RA) was found between groups (P=.156). VBL and HBLo increased significantly at T3 compared with T1 for both groups (P<.005). After 3 years, VBL were 1.36 ±0.57 mm and 1.0 ±0.44 mm and HBLo were 0.88 ±0.48 mm for BA and 0.77 ±0.53 mm for RA. At T1 and T3, BA had more significant VBL than RA (P<.001), while HBLo did not differ significantly between groups. For both groups, a significant difference was found in VBL and HBLo between implant sites (P<.001). The B site recorded the highest VBL, and the L site recorded the lowest VBL. The M and D sites recorded the highest HBLo, and the B and L sites recorded the lowest HBLo. Two nonsplinted immediately loaded implants retaining mandibular overdentures were associated with significantly higher vertical and horizontal circumferential bone loss than those associated with splinted implants after a follow-up of 3 years. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Xiao, Jian-rui; Li, Yong-Qi; Guan, Su-Min; Kong, Liang; Liu, Baolin; Li, Dehua
2012-03-01
Our aim was to evaluate the effects of lateral cortical anchorage on the primary stability of implants subjected to immediate loading. Implants were placed into bovine bones with monocortical anchorage (implant placed through the cortical bone of the crest) and bicortical anchorage (the crest cortical bone plus one cortical bone on the lateral side). Loads of 25N and 50N were applied to the implants in different cycles. The implant stability quotient (ISQ) was measured before and after the cyclic loadings. Under 25N load there was no difference in ISQ between 1800 cyclic loading and preloading, but the values decreased significantly after 3600 cyclic loading in both groups (p<0.05). Under a 50N load the ISQ value after 1800 and 3600 cyclic loading decreased in the monocortical group (p<0.05), but there was no difference between 1800 cyclic loading and preloading in the bicortical group, and the ISQ in the bicortical group was higher than in the monocortical group after 1800 cyclic loading (p<0.05). Our results suggest that the stability of implants with bicortical anchorage decreased more slowly under higher loads. Copyright © 2011 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Implant Insertion Torque: Its Role in Achieving Primary Stability of Restorable Dental Implants.
Greenstein, Gary; Cavallaro, John
2017-02-01
A literature review was conducted to determine the role of insertion torque in attaining primary stability of dental implants. The review is comprised of articles that discussed the amount of torque needed to achieve primary implant stability in healed ridges and fresh extraction sockets prior to immediate implant loading. Studies were appraised that addressed the effects of minimum and maximum forces that can be used to successfully place implants. The minimum torque that can be employed to attain primary stability is undefined. Forces ≥30 Ncm are routinely used to place implants into healed ridges and fresh extraction sockets prior to immediate loading of implants. Increased insertion torque (≥50 Ncm) reduces micromotion and does not appear to damage bone. In general, the healing process after implant insertion provides a degree of biologic stability that is similar whether implants are placed with high or low initial insertion torque. Primary stability is desirable when placing implants, but the absence of micromotion is what facilitates predictable implant osseointegration. Increased insertion torque helps achieve primary stability by reducing implant micromotion. Furthermore, tactile information provided by the first surgical twist drill can aid in selecting the initial insertion torque to achieve predictable stability of inserted dental implants.
Luongo, Giuseppe; Oteri, Giacomo
2010-01-01
A new chemically modified titanium surface, SLActive, has recently been developed. The results obtained in controlled clinical trials indicate that this implant can be safely used and that it offers predictable results. The goal of this noninterventional study was to verify that the success rates of implants used in daily dental practice are comparable to those reported in controlled clinical trials. This study was a prospective, noninterventional study using implants with a chemically modified surface according to the daily dental practice procedures applied by private practitioners. The choice of the implantation procedure and the loading protocol were the responsibility of the investigator and were chosen according to the patient's needs. Thirty clinical centers actively participated in this study, and 226 patients were treated, of which, 8 patients were lost to follow-up. Because of the noninterventional design of the study, the patients were not selected according to strictly defined inclusion/exclusion criteria. Thus, the study included individuals with risk factors such as smoking (24%), untreated gingivitis or periodontitis (9%), and bruxism (6%). The implants were equally distributed between mandible (46%) and maxilla (54%). A bone augmentation procedure was done in 31% of the cases. Early loading (functional loading between 48 hours and 3 months after implant insertion) was applied most frequently (48%), followed by the conventional loading protocol (3 to 6 months after implant placement, 34%). Immediate restoration and immediate loading were rare (7% and 2%, respectively). Of 276 implants inserted and documented, 5 implants failures were reported, all of which were associated with a sinus floor augmentation procedure. The survival rate was 98.2% at the 1-year follow-up visit. The results showed that implants with a chemically modified surface can be successfully restored with success rates similar to those reported in formal clinical trials under more controlled conditions.
Álvarez-Camino, Juan C.; Valmaseda-Castellón, Eduard
2013-01-01
Objetives: The development of treated implant surfaces, added to the increase of the aesthetic requirements by the patients has led to a change in the treatment protocols as well as the development of techniques such as the one-fase implants and the immediate prosthetic loading. One of the usual contraindications of the implant treatment is the presence of periapical disease associated to the tooth to be replaced. The aim of this paper is to review the published literature on immediate implant placement in extraction sockets of teeth with periapical pathology, considering the level of scientific evidence, and following the principles of medicine and evidence-based Dentistry. Material and Methods: A search of articles published between 1982 and 2012 was conducted. The search terms immediate, dental implant, extraction, infected, periapical pathology were used. Search was limited to studies in animals and humans, published in english language. Results: 16 articles were selected from a total of 438, which were stratified according to their level of scientific evidence using the SORT criteria (Strength of Recommendation Taxonomy). Studies in both animals and humans presented high rates of implant survival, but human studies are limited to a small number of cases. Discussion and Conclusions: There is a limited evidence regarding implant placement immediately to the extraction of teeth affected by chronic periapical pathology. Following analysis of the articles, and in function of their scientific quality, a type B recommendation is given in favor of the immediate implant placement in fresh sockets associated to periapical infectious processes. Key words:Immediate implant, periapical pathology. PMID:23722139
Simulation of peri-implant bone healing due to immediate loading in dental implant treatments.
Chou, Hsuan-Yu; Müftü, Sinan
2013-03-15
The goal of this work was to investigate the role of immediate loading on the peri-implant bone healing in dental implant treatments. A mechano-regulatory tissue differentiation model that takes into account the stimuli through the solid and the fluid components of the healing tissue, and the diffusion of pluripotent stem cells into the healing callus was used. A two-dimensional axisymmetric model consisting of a dental implant, the healing callus tissue and the host bone tissue was constructed for the finite element analysis. Poroelastic material properties were assigned to the healing callus and the bone tissue. The effects of micro-motion, healing callus size, and implant thread design on the length of the bone-to-implant contact (BIC) and the bone volume (BV) formed in the healing callus were investigated. In general, the analysis predicted formation of a continuous layer of soft tissue along the faces of the implant which are parallel to the loading direction. This was predicted to be correlated with the high levels of distortional strain transferred through the solid component of the stimulus. It was also predicted that the external threads on the implant, redistribute the interfacial load, thus help reduce the high distortional stimulus and also help the cells to differentiate to bone tissue. In addition, the region underneath the implant apex was predicted to experience high fluid stimulus that results in the development of soft tissue. The relationship between the variables considered in this study and the outcome measures, BV and BIC, was found to be highly nonlinear. A three-way analysis of variance (ANOVA) of the results was conducted and it showed that micro-motion presents the largest hindrance to bone formation during healing. Copyright © 2013 Elsevier Ltd. All rights reserved.
Lin, Thomas H S; Chen, Leon; Cha, Jennifer; Jeffcoat, Marjorie; Kao, Daniel W K; Nevins, Myron; Fiorellini, Joseph P
2012-06-01
The purpose of this study was to determine the effect of cigarette smoking and residual native bone height on the survival of dental implants placed immediately in grafted sinuses. In this retrospective study, 334 subject records were screened, and 75 subjects (155 implants) were included. Data collection based on treatment notes and radiographs included age, sex, smoking status, sinus floor bone height, dental implant information, and implant survival. The survival rates of implants for nonsmokers and smokers at stage-two surgery were 93% and 84%, respectively. After 12 months of functional loading, the survival rates of implants for nonsmokers and smokers were 87% (81 of 93) and 79% (49 of 62), respectively (P < .000). Analysis revealed that the effect of smoking on implant survival is significant when the preoperative bone height is less than 4 mm, with an 82.4% implant survival rate in nonsmokers compared to 60% in smokers (P < .05). Smoking should be considered as a high risk factor when implants are placed immediately in grafted sinuses, particularly in areas of limited bone height.
Hasan, I; Röger, B; Heinemann, F; Keilig, L; Bourauel, C
2012-09-01
The aim of the present study was to investigate experimentally and numerically the influence of a fine threaded- against a roughened-cervical region of immediately loaded dental implants in combination with straight and 20°-angled abutments on the implant primary stability. A total of 30 implants were inserted in bovine rib-segments, 14 cervically roughened implants and 16 implants with fine cervical threads. Each implant system received two abutments, straight and 20°-angled. Implant displacements and rotations were measured using a biomechanical measurement system. Subsequently, eight samples were selected for geometrical reconstruction and numerical investigation of stress and strain distributions in the bone by means of the finite element method. Experimentally, both implant systems showed similar behaviour with the straight abutments concerning displacements and rotations. However, fine threaded implants showed much less displacement and rotation against roughened implants when angled abutments were considered. Numerically, stresses were within 35-45 MPa in the cortical bone for both implant systems. The strains showed highest values within the spongious bone with the roughened implants connected to angled abutments. The results indicate that implants with fine cervical threads could be recommended in particular with angled abutments. The outcomes of this study are currently confirmed by long-term clinical investigations. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.
Stability of tapered and parallel-walled dental implants: A systematic review and meta-analysis.
Atieh, Momen A; Alsabeeha, Nabeel; Duncan, Warwick J
2018-05-15
Clinical trials have suggested that dental implants with a tapered configuration have improved stability at placement, allowing immediate placement and/or loading. The aim of this systematic review and meta-analysis was to evaluate the implant stability of tapered dental implants compared to standard parallel-walled dental implants. Applying the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) statement, randomized controlled trials (RCTs) were searched for in electronic databases and complemented by hand searching. The risk of bias was assessed using the Cochrane Collaboration's Risk of Bias tool and data were analyzed using statistical software. A total of 1199 studies were identified, of which, five trials were included with 336 dental implants in 303 participants. Overall meta-analysis showed that tapered dental implants had higher implant stability values than parallel-walled dental implants at insertion and 8 weeks but the difference was not statistically significant. Tapered dental implants had significantly less marginal bone loss compared to parallel-walled dental implants. No significant differences in implant failure rate were found between tapered and parallel-walled dental implants. There is limited evidence to demonstrate the effectiveness of tapered dental implants in achieving greater implant stability compared to parallel-walled dental implants. Superior short-term results in maintaining peri-implant marginal bone with tapered dental implants are possible. Further properly designed RCTs are required to endorse the supposed advantages of tapered dental implants in immediate loading protocol and other complex clinical scenarios. © 2018 Wiley Periodicals, Inc.
Daas, M.; Assaf, A.; Dada, K.; Makzoumé, J.
2015-01-01
Statement of Problem. Low scientific evidence is identified in the literature for combining implant placement in fresh extraction sockets with immediate function. Moreover, the few studies available on immediate implants in postextraction sites supporting immediate full-arch rehabilitation clearly lack comprehensive protocols. Purpose. The purpose of this study is to report outcomes of a comprehensive protocol using CAD-CAM technology for surgical planning and fabrication of a surgical template and to demonstrate that immediate function can be easily performed with immediate implants in postextraction sites supporting full-arch rehabilitation. Material and Methods. 14 subjects were consecutively rehabilitated (13 maxillae and 1 mandible) with 99 implants supporting full-arch fixed prostheses followed between 6 and 24 months (mean of 16 months). Outcome measures were prosthesis and implant success, biologic and prosthetic complications, pain, oedema evaluation, and radiographic marginal bone levels at surgery and then at 6, 12, 18, and 24 months. Data were analyzed with descriptive statistics. Results. The overall cumulative implant survival rate at mean follow-up time of 16 months was 97.97%. The average marginal bone loss was 0,9 mm. Conclusions. Within the limitations of this study, the results validate this treatment modality for full-arch rehabilitations with predictable outcomes and high survival rate after 2 years. PMID:26064119
Gritsch, Kerstin; Laroche, Norbert; Bonnet, Jeanne-Marie; Exbrayat, Patrick; Morgon, Laurent; Rabilloud, Muriel; Grosgogeat, Brigitte
2013-01-01
The present work intends to evaluate the use of immediate loaded orthodontic screws in a growing model, and to study the specific bone response. Thirty-two screws (half of stainless steel and half of titanium) were inserted in the alveolar bone of 8 growing pigs. The devices were immediately loaded with a 100 g orthodontic force. Two loading periods were assessed: 4 and 12 weeks. Both systems of screws were clinically assessed. Histological observations and histomorphometric analysis evaluated the percent of “bone-to-implant contact” and static and dynamic bone parameters in the vicinity of the devices (test zone) and in a bone area located 1.5 cm posterior to the devices (control zone). Both systems exhibit similar responses for the survival rate; 87.5% and 81.3% for stainless steel and titanium respectively (p = 0.64; 4-week period), and 62.5% and 50.0% for stainless steel and titanium respectively (p = 0.09; 12-week period). No significant differences between the devices were found regarding the percent of “bone-to-implant contact” (p = 0.1) or the static and dynamic bone parameters. However, the 5% threshold of “bone-to-implant contact” was obtained after 4 weeks with the stainless steel devices, leading to increased survival rate values. Bone in the vicinity of the miniscrew implants showed evidence of a significant increase in bone trabecular thickness when compared to bone in the control zone (p = 0.05). In our study, it is likely that increased trabecular thickness is a way for low density bone to respond to the stress induced by loading. PMID:24124540
Hita-Iglesias, Cristina; Sánchez-Sánchez, Francisco J; Montero, Javier; Galindo-Moreno, Pablo; Mesa, Francisco; Martínez-Lara, Ildefonso; Sánchez-Fernández, Elena
2016-12-01
To compare the immediate implant success rates between sites with chronic apical lesions and healthy sites in the same patients 1 year postdelayed loading. One hundred sixty-eight immediate implants were placed in sixty patients at upper incisor, canine, and premolar sites. A split-mouth design was used, placing a minimum of two implants, one in a fresh socket associated with chronic periapical disease, the average lesion size was larger than 4 mm and less than 8 mm (test group), and the other(s) in a healthy fresh socket (control group). Implant survival rate at 1 year postloading delayed was compared between the groups. The implant survival rate was 98.2% for the total sample (n = 168); out of the three implants lost, two were from the test group, and one was from the control group (in the same patient as one of the former). Among the surviving implants, five were also considered failures due to excessive bone loss (n = 3) and also because of the recurrence of the periapical lesions (n = 2). Survival rates were significantly lower in the test than control sites at 12 months postloading. Implant survival rates were significantly lower after the immediate implantation in postextraction sockets associated with chronic periapical disease (90.8%) than in healthy postextraction sockets (98.1%). © 2015 Wiley Periodicals, Inc.
ArRejaie, Aws; Al-Harbi, Fahad; Alagl, Adel S; Hassan, Khalid S
2016-01-01
This study clinically and radiographically investigated the potential of platelet-rich plasma (PRP) gel combined with bovine-derived xenograft to treat dehiscence defects around immediate dental implants. This study was performed on 32 sites from 16 patients who each received an immediate implant for a single tooth replacement at a maxillary anterior or premolar site. Patients were divided into two groups according to the augmented materials used. One group received an immediate implant and filling of defects using a PRP gel plus bovine-derived xenograft. The other group received an immediate implant and filling of defects with a bovine-derived xenograft without PRP gel. Cone beam computed tomography (CBCT) was taken before placement, and at 6 and 12 months postsurgery. Both treatment procedures resulted in significant improvements for the primary outcome regarding bone fill, as well as the marginal bone level. In addition, statistically significant differences were found in the bone density for the combined therapy compared with sites treated with bovine-derived xenografts alone (P ≤ .01). Autogenous PRP gel combined with bovine-derived xenograft demonstrated superiority to the bovine-derived xenograft alone, which suggested that it could be successfully applicable for the treatment of dehiscence around an immediate dental implant. Moreover, CBCT can be used to measure dehiscence and to assess bone thickness along the implant.
An Intraoperative Site-specific Bone Density Device: A Pilot Test Case.
Arosio, Paolo; Moschioni, Monica; Banfi, Luca Maria; Di Stefano, Anilo Alessio
2015-08-01
This paper reports a case of all-on-four rehabilitation where bone density at implant sites was assessed both through preoperative computed tomographic (CT) scans and using a micromotor working as an intraoperative bone density measurement device. Implant-supported rehabilitation is a predictable treatment option for tooth replacement whose success depends on the clinician's experience, the implant characteristics and location and patient-related factors. Among the latter, bone density is a determinant for the achievement of primary implant stability and, eventually, for implant success. The ability to measure bone density at the placement site before implant insertion could be important in the clinical setting. A patient complaining of masticatory impairment was presented with a plan calling for extraction of all her compromised teeth, followed by implant rehabilitation. A week before surgery, she underwent CT examination, and the bone density on the CT scans was measured. When the implant osteotomies were created, the bone density was again measured with a micromotor endowed with an instantaneous torque-measuring system. The implant placement protocols were adapted for each implant, according to the intraoperative measurements, and the patient was rehabilitated following an all-on-four immediate loading protocol. The bone density device provided valuable information beyond that obtained from CT scans, allowing for site-specific, intraoperative assessment of bone density immediately before implant placement and an estimation of primary stability just after implant insertion. Measuring jaw-bone density could help clinicians to select implant-placement protocols and loading strategies based on site-specific bone features.
Cooper, Lyndon F; Reside, Glenn J; Raes, Filiep; Garriga, Joan Soliva; Tarrida, Luis Giner; Wiltfang, Jörg; Kern, Matthias; De Bruyn, Hugo
2014-01-01
This 5-year prospective multicenter study compared implant survival and success, peri-implant health and soft tissue responses, crestal bone level stability, and complication rates following immediate loading of single OsseoSpeed implants placed in anterior maxillary healed ridges or extraction sockets. Individuals requiring anterior tooth replacement with single implants were treated and immediately provisionalized. Definitive all-ceramic crowns were placed at 12 weeks. Implant survival, bone levels, soft tissue levels, and peri-implant health were monitored for 5 years. One hundred thirteen patients received implants in fresh sockets (55) and healed ridges (58). After 5 years, 45 and 49 patients remained for evaluation, respectively. During the first year, three implants failed in the extraction socket group (94.6% survival) and one implant failed in the healed ridge group (98.3% survival); this difference was not significant. No further implant failures were recorded. After 5 years, the interproximal crestal bone levels were located a mean of 0.43 ± 0.63 mm and 0.38 ± 0.62 mm from the reference points of implants in sockets and healed ridges (not a significant difference). In both groups, papillae increased over time and peri-implant mucosal zenith positions were stable from the time of definitive crown placement in sockets and healed ridges. Compared to flap surgery for implants in healed ridges, flapless surgery resulted in increased peri-implant mucosal tissue dimension (average, 0.78 ± 1.34 mm vs 0.19 ± 0.79 mm). After 5 years, the bone and soft tissue parameters that characterize implant success and contribute to dental implant esthetics were similar following the immediate provisionalization of implants in sockets and healed ridges. The overall tissue responses and reported implant survival support the immediate provisionalization of dental implants in situations involving healed ridges and, under ideal circumstances, extraction sockets.
Bressan, Eriberto; Grusovin, Maria Gabriella; D'Avenia, Ferdinando; Neumann, Konrad; Sbricoli, Luca; Luongo, Giuseppe; Esposito, Marco
To evaluate the influence of at least three abutment disconnections in conventional loaded implants against placement of a definitive abutment in immediately non-occlusal loaded implants on hard and soft tissue changes. A secondary aim was to evaluate whether the presence of less than 2 mm of keratinised mucosa is associated with increased peri-implant marginal bone loss and soft tissue recessions. Eighty patients requiring one single crown or one fixed partial prosthesis supported by a maximum of three implants were randomised, after implants were placed with more than 35 Ncm, according to a parallel group design to receive definitive abutments that were loaded immediately (definitive abutment or immediate loading group) or transmucosal abutments, which were delayed loaded after 3 months and removed at least three times: 1. At impression taking (3 months after implant placement); 2. When checking the zirconium core on titanium abutments at single crowns or the fitting the metal structure at prostheses supported by multiple implants; 3. At delivery of the definitive prostheses (repeated disconnection or conventional loading group). Patients were treated at four centres and each patient contributed to the study, with only one prosthesis followed for 3 years after initial loading. Outcome measures were: prosthesis failures, implant failures, complications, pink aesthetic score (PES), buccal recessions, patient satisfaction, peri-implant marginal bone level changes and height of the keratinised mucosa. Forty patients were randomly allocated to each group according to a parallel group design. Six patients from the definitive abutment group dropped out or died, and one left from the repeated disconnection group. One implant, from the repeated disconnection group, fractured (difference = 3%; CI 95%: -2%, 8%; P = 1). Four provisional crowns and one definitive single crown had to be remade because of poor fitting, and one definitive crown and one definitive prosthesis because of ceramic and implant fracture, respectively, in the repeated disconnection group vs one provisional prosthesis from the definitive abutment group due to frequent debondings (difference = 15%; CI 95%: 2%, 28%; P = 0.060). Five patients from the definitive abutment group and four patients from the repeated disconnection group were affected by complications (difference = 4%; CI 95%: -11%, 20%; P = 0.725). PES scores assessed at 3 years post-loading were 11.7 (standard deviation = 1.8) mm for the definitive abutment group and 11.3 (1.5) mm for the repeated abutment changes group (difference = 0.4; CI 95%: -0.4, 1.2; P = 0.315). However, there was a difference of 0.26 out of a maximum score of 2 in favour of the definitive abutment group for soft tissue contour only. Buccal recessions at 3 years post-loading amounted to -0.1 (0.8) mm for the definitive abutment group and -0.1 (1.2) mm for the repeated abutment changes group (it was actually a soft tissue gain; difference = 0.01 mm CI 95%: -0.48, 0.50; P = 0.965). All patients declared being very satisfied or satisfied with the function and aesthetics of the prostheses and said they would undergo the same procedure again, with the exception of one patient from the repeated disconnection group who was uncertain regarding function. Mean peri-implant marginal bone loss 3 years after loading was 0.07 (0.18) mm for the definitive abutment group and 0.50 (0.93) mm for the repeated abutment changes group (difference = 0.43 mm; CI 95%: 0.13, 0.74; P = 0.007). The height of keratinised mucosa at 3 years post-loading was 2.8 (1.3) mm for the definitive abutment group and 2.8 (1.6) mm for the repeated abutment changes group (difference = 0.03; CI 95%: -0.67, 0.73; P = .926). Up to 3 years after initial loading there were no statistically significant differences between the two procedures, with the exception of 0.4 mm more marginal bone loss at implants subjected to three abutment disconnections. There were no significantly increased marginal bone loss (difference = 0.1 mm, CI 95%: -0.3, 0.5, P = 0.590) or buccal recessions (difference = 0.1 mm, CI 95%: -0.4, 0.7, P = 0.674) at implants with less than 2 mm of keratinised mucosa at loading. Three-year post-loading data showed that repeated abutment disconnections significantly increased bone loss of 0.43 mm, but this difference may not be considered clinically relevant; therefore clinicians can use the procedure they find more convenient for each specific patient. Immediately non-occlusally loaded dental implants are a viable alternative to conventional loading and no increased bone loss or buccal recessions were noticed at implants with less than 2 mm of keratinised mucosa. Conflict of interest statement: This trial was partially funded by Dentsply Sirona Implants, the manufacturer of the implants and other products evaluated in this investigation. However, data belonged to the authors and by no means did the manufacturer interfere with the conduct of the trial or the publication of the results, with the exception of rejecting a proposal to change the protocol, after the trial was started, allowing the use of indexed abutments.
Evaluation of the success and complication rates of self-drilling orthodontic mini-implants.
Gurdan, Z; Szalma, J
2018-05-01
Orthodontic mini-implants are important devices for successful anchorage management in orthodontics; however, the survival of these devices depends on several clinical factors. The aim of our study was to calculate the success and complication rates of orthodontic mini-implants. In this retrospective study, patients of our orthodontic department were enrolled, getting overall 59 orthodontic mini-implants during their orthodontic treatment in a 2-year period. Every patient had one or more of the 1.6 mm × 8 mm in size self-drilling mini-implants (Jeil Dual Top Anchor System, Jeil Medical Corp., Seoul, Korea). Screw loading was performed immediately after insertions, keeping tension forces under 150 g. Soft tissue and bone infections, implant mobility and screw loss, implant fracture, and neighboring tooth injury were registered. Relationships between variables were tested using the Chi-square test for statistical significance. The success rate of the orthodontic mini-implants was 89.8% in this study while the average loading period was 8.1 months. Soft-tissue infections varied between 6.3% and 33.3% of the cases while screw mobility varied between 3.1% and 20.8% of the cases regarding the anatomic localization. Screw mobility was significantly more frequent in the buccal fold than in the palate (P = 0.034). Screw mobility was significantly more frequent in the buccal fold than in the palate (P = 0.034) and screw mobility was found more frequently in case of intrusions than by extrusions (P = 0.036). The overall success rate of mini-implants was found acceptable in this study, however, screw mobility in the buccal fold showed a high incidence, suggesting the thorough consideration of the immediate loading by buccal mini-implants.
Piano, Sergio; Romeo, Eugenio; Sbricoli, Luca; Pisoni, Gianluca; Cea, Niccoló; Lops, Diego
2016-12-01
The aim of this study was to verify the reliability of a system for the fixed retention of complete maxillary prostheses supported by four implants with a follow-up of 2 years. Patients were treated between September 2009 and December 2010 with four Straumann Bone Level SLActive implants supporting a complete prosthesis (CPs). The two distal implants were positioned mesially to the maxillary sinus and with a mesio-distal inclination ≤ 30° in order to reduce the distal prosthesis cantilever. An immediate loading surgical protocol was used. The CPs were planned to be fixed to multibase abutments to test their retention for a fixed rehabilitation. Clinical and radiographic parameters as probing pocket depth (PPD), bleeding score (mBI), plaque index (PI), and marginal bone loss (MBL) were assessed at a 1- and 2-year follow-up visits. Moreover, any biological and prosthodontic maintenance events were recorded. Clinical and radiographic parameters changes were analyzed. Twenty-one patients treated with a total of 84 implants completed the 2-year examination period. Four patients were lost to follow up. No technical complication was recorded. Also, no implant, reconstruction, or abutment failures were observed. Therefore, an implant and prosthetic survival rate of 100% were achieved after 2 years. The mean periodontal parameter scores after 2 years of function were 2.6 mm for PPD (SD 0.8 mm), 0.3 for mBI (SD 0.5 mm), and 1.2 for PI (SD 0.4 mm) indexes, respectively. In addition, the mean MBL score measured at the 2-year follow-up visit was -0.34 mm (SD of -0.45 mm). Furthermore, no peri-implant soft tissue inflammation or peri-implant infection was observed. It has been shown that immediate loading of four implants positioned anteriorly to the maxillary sinus could be a reliable treatment procedure to support fixed complete restorations. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Migliorati, Marco; Amorfini, Leonardo; Signori, Alessio; Biavati, Armando Silvestrini; Benedicenti, Stefano
2015-10-01
The aesthetic outcome of an implant-supported restoration is first of all dependent on the soft tissue volume. Because the labial bone plate resorbs in every direction after tooth extraction, even when an implant is placed immediately, most patients end up with compromised aesthetics. In this parallel-designed, randomized clinical trial, participants were randomly assigned to the test group (immediate load post-extractive implant treated with subepithelial connective tissue graft placed using the tunnel technique in the labial area) and control group (immediate load post-extractive implant treated without raising a flap) with an allocation ratio of 1:1. Both groups received deproteinized bovine bone mineral. Patients were observed at baseline, crown insertion, 1-year follow-up, and 2-year follow-up. Clinical, radiological and aesthetic parameters were recorded to assess primary treatment outcomes. A random permuted block system was blindly generated ensuring uniformity of the patient allocation during the trial by randomly distributing three participants to the test and three participants to the control group every six treated patients. At the 2-year examination, all 47 implants were successfully integrated, demonstrating stability and healthy peri-implant soft tissues as documented by standard clinical parameters. The results showed a soft tissue remodeling of -10% in thickness and -18% in highness in the non-grafted group, whereas in the grafted group there was a gain of 35% in thickness and a slight reduction of -11% in highness. Test group reported an increase of aesthetic result (mean pink aesthetic score [PES] 8) compared with control group (mean PES 6.65). This prospective study demonstrates the effectiveness of placing a soft tissue graft at the time of immediate implant placement in the aesthetic zone. At the 2-year follow-up, test group revealed a better aesthetic outcomes and stable facial soft tissues compared with control group. © 2013 Wiley Periodicals, Inc.
Quaranta, Alessandro; Perrotti, Vittoria; Putignano, Angelo; Malchiodi, Luciano; Vozza, Iole; Calvo Guirado, José Luis
2016-04-01
The anatomical remodeling technique (ART) was proposed to place postextraction implants with the aid of specific osteotomes. This study is a clinical and radiographic evaluation with 10-year follow-up of anterior postextraction single implants placed with the ART and immediately restored. Thirty-five patients, with a hopeless tooth in the anterior maxilla, were included in the study and 35 implants were inserted according to the ART. Clinical and radiographic evaluations were performed at baseline (T0), after 6 (T1) and 14 months (T2), 4 years after surgery (T3) and every other year up to the 10-year follow-up (T4, T5, and T6). Implant success, survival, and failure rates were evaluated according to the International Congress of Oral Implantologists Pisa Consensus Conference criteria. Twenty-nine patients and 29 implants were available for the 10-year data analysis. After 10 years, the accumulated mean marginal bone loss was 2.69 ± 0.42 mm. The cumulative survival rate of the implants was 100%. Immediately loaded postextractive implants, placed according to the ART, have been proved to be a predictable method to rehabilitate single tooth in the anterior maxilla.
2016-01-01
PURPOSE Early loading of implant can be determined by excellent primary stability and characteristic of implant surface. The implant system with recently improved surface can have load application 4-6 weeks after installing in maxilla and mandible. This study evaluated the effect of healing period to the stability of hydrophilic tapered-type implant at maxillary posterior area. MATERIALS AND METHODS This study included 30 patients treated by hydrophilic tapered-type implants (total 41 implants at maxilla) and classified by two groups depending on healing period. Group 1 (11 patients, 15 implants) was a control group and the healing period was 12 weeks, and Group 2 (19 patients, 26 implants) was test group and the healing period was 6 weeks. Immediately after implant placement, at the first impression taking, implant stability was measured using Osstell Mentor. The patients also took periapical radiographs after restoration delivery, 12 months after restoration and final followup period. The marginal bone loss around the implants was measured using the periapical radiographs. RESULTS All implants were survived and success rate was 97.56%. The marginal bone loss was less than 1mm after 1 year postoperatively except the one implant. The stabilities of the implants were not correlated with age, healing period until loading, insertion torque (IT), the diameter of fixture and the location of implant. Only the quality of bone in group 2 (6 week) was correlated with the stability of implant. CONCLUSION Healing period of 6 weeks can make the similar clinical prognosis of implants to that of healing period of 12 weeks if bone quality is carefully considered in case of early loading. PMID:27826390
Marra, Roberto; Acocella, Alessandro; Rispoli, Alessandra; Sacco, Roberto; Ganz, Scott D; Blasi, Andrea
2013-10-01
The purpose of this report is to present the clinical outcomes and patients' satisfaction of full-mouth rehabilitation using computer-aided flapless implant placement and immediate loading of a prefabricated prosthesis. The study included 30 consecutive fully edentulous patients who received 312 implants. Mandible and maxilla were treated in the same surgical session with computer-guided flapless approach using the NobelGuide protocol. Prefabricated screw-retained fixed prostheses were inserted at the end of surgery. Clinical and radiographic evaluations were assessed at 6, 12, and 36 months. At baseline and 6 months after surgery, patients answered Oral Health Impact Profile in Edentulous Adults questionnaire to assess satisfaction. The implant survival rate was 97.9%, whereas the average marginal bone loss was 1.9 ± 1.3 mm after 3 years. At 6 months, patients showed significantly greater satisfaction with their fixed rehabilitation when compared with conventional dentures. The results of this study confirm that rehabilitation with a prefabricated fixed prosthesis supported by implants placed with NobelGuide protocol is a viable and predictable treatment and increases patients' satisfaction and improves oral health-related quality of life.
Yin, Lihua; Yu, Zhanhai; Chen, Zhuofan; Huang, Baoxin; Zhang, Kailiang; Zhou, Ailing; Li, Xiangxin
2016-08-01
To retrospectively assess the changes of the vertical height of the maxillary sinus floor after augmentation with simultaneous and delayed placement of implants. In total, 38 patients with 76 implants were involved; vertical bone height of the sinus floor was radiographically measured at different stages including preoperation, immediately postsurgery, 6 and 12 months postsurgery, and 6 and 24 months postfunctional loading. Sinus augmentation significantly increased vertical bone height of the sinus floor for both the simultaneous and delayed groups. The survival rate was 100% in the simultaneous group and 95.46% in the delayed group. For simultaneous placement, the vertical bone height of the sinus floor at 6 and 12 months postsurgery was significantly less than that immediately postsurgery. For both groups, augmented bone height of the sinus floor showed significant decrease from 6 months to 24 months postfunctional loading. The mean value of final bone augmentation was 5.85 mm for simultaneous placement and 5.80 mm for delayed placements. Sinus augmentation with simultaneous and delayed placement of implants led to similar survival rates and bone augmentation. Resorption of augmentative bone was evident at 24 months postfunctional loading in both cases. © 2015 by the American College of Prosthodontists.
Nik, Shahram Namjoy; Nejatian, Touraj
2016-12-01
Clinical efficiency of one-piece screw-type implants with telescopic were attachments evaluated in this study. Twenty-four patients received a mandibular implant-supported overdenture and maxillary complete denture. Ninety-six one-piece implants were inserted in the inter-foraminal area. Implants were immediately loaded with an implant-retained overdenture and telescopic attachments which had frictional retention elements. There was 0.25±0.24 mm, 0.32±0.25 mm, 0.43±0.30 mm, 0.61±0.30 mm and of bone resorption after 3, 6, 12 and 24 months, respectively. The need to activate the frictional retention was the most common complication. Treatment outcomes for prefabricated telescopic retained overdentures on one-piece implants are similar to that obtained in cases of delayed loading. Copyright© 2016 Dennis Barber Ltd.
Immediate Implant Placement in Sockets with Asymptomatic Apical Periodontitis.
Crespi, Roberto; Capparé, Paolo; Crespi, Giovanni; Lo Giudice, Giuseppe; Gastaldi, Giorgio; Gherlone, Enrico
2017-02-01
The purpose of the present study was to evaluate if the presence of granulation tissue in asymptomatic apical periodontitis compromised immediate implant placement. Patients requiring extraction of one tooth (maxillary and mandibular incisive, canine or premolar) with asymptomatic apical periodontitis, were recruited for this prospective study. They were randomly scheduled into two groups: in first group (A) including 30 teeth, reactive soft tissue was debrided before implant placement, and in second group (B) including 30 teeth, reactive soft tissue was left in the apical lesion. Implants were positioned immediately after tooth extraction, and were loaded after 3 months in both groups. Cone beam computed tomography was performed before tooth extraction and at 1-year follow-up to evaluate the radiolucency around the root apex and the implant, bucco-lingual bone levels were also checked. Sixty patients were included in this study. Sixty implants were placed immediately after tooth extraction and, at 1-year follow-up, a survival rate of 100% was reported. After one year both groups showed absence of radiolucent zone at the apical region of implants. All fresh sockets presented a buccal-palatal bone reduction in both groups after one year, even if not statistically significant differences were found between baseline bone levels and within groups. Within the limitations of the present study, the immediate placement of implants into the extraction sockets with asymptomatic apical periodontitis, in presence of primary stability, did not lead to an increased rate of complications and rendered an equally favorable type of tissue integration. © 2016 Wiley Periodicals, Inc.
Drago, Carl
2016-08-01
The purpose of this report was to retrospectively evaluate implant and immediate full-arch prosthesis survival rates over a 24-month period; patients were consecutively treated with immediate occlusal loading. Dental arch, gender, and implant orientation (vertical vs. tilted) were also noted. All Brånemark System implants (Nobel Active) and interim, all-acrylic resin prostheses placed in patients following an All-on-Four™ protocol, in a single private practice were assessed by retrospective patient chart review. The amount of space provided surgically for implant restorative components and prostheses was determined from measurements of the vertical heights of the interim prostheses in the right/left anterior and posterior segments. These measurements were made in the laboratory. Interim prosthetic repairs (type, frequency, length of time from insertion) were analyzed by type, arch, gender, and implant orientation. Implant survival and insertion torque values were also measured. Inclusion criteria consisted of all Brånemark System implants placed with the All-on-Four protocol from September 1, 2011, until August 31, 2013. Specific dietary instructions were given for the first 7 days immediately postoperatively and for the weeks prior to insertion of the definitive prostheses. One hundred twenty-nine patients, comprising 191 arches (766 implants) from September 1, 2011, until August 31, 2013, were included in the study. One patient experienced implant failure yielding an overall implant survival rate (SR) of 99.5% (762 of 766). Four hundred twenty-six of 430 maxillary implants and 336 of 336 mandibular implants survived for SRs of 99.1% and 100%, respectively. Regarding implant orientation, 415 of 417 tilted implants (SR 99.5%) and 343 of 345 (CSR 95.6%) vertical implants were noted to be clinically stable. Interim, all-acrylic resin prostheses were in place for a mean of 199.2 days; mandibular prostheses were in place for an average of 195.4 days; maxillary prostheses were in place for an average of 202.0 days. Thirty four of the 191 interim prostheses (17.8%) warranted at least one repair during the treatment period. The average overall implant insertion torque value was 60.74 Ncm; mandibular torque values averaged 63.08 Ncm; maxillary torque values averaged 59.00 Ncm. The results from this study suggest that dental arch, gender, and implant orientation for implants placed and immediately restored with interim, all-acrylic resin, full-arch prostheses per the All-on-Four protocol did not have significant statistical or clinical effects on prosthetic complications of the interim prostheses or implant survival. Only one of the 129 patients experienced implant failures, indicating that the All-on-Four treatment protocol used in this study is a viable alternative to other protocols for rehabilitating edentulous patients. © 2015 by the American College of Prosthodontists.
Comparative analysis of anchorage systems for micro implant orthodontics.
Favero, Lorenzo; Giagnorio, Costantino; Cocilovo, Francesco
2010-01-01
The study analysed twelve anchorage systems based on micro implants in terms of their bio-mechanical properties and appraised their actual clinical effectiveness. The analysed micro implants had data provided by the manufacturers or extracted from articles published in specialised journals. The parameters taken into account were: material, surface treatment, head type, length, diameter, neck length, filleted self drilling or self tapping surface, applicable orthodontic forces, possibility of immediate loading, and device removal. Material Grade 5 titanium, titanium alloy (TiAl6V4), surgical steel; surfaces: smooth, sand-blasted and acid etched; head type: bracket, conic with button, round, hexagonal, button with cross cuts, double melted sphere; lengths: between 8.0 to 14 mm; diameters: between 1.2 to 2.0 mms; neck lengths: inferior to 1.5mm and superior to 2.0mm; filleted portion: self tapping and/or self drilling; applicable orthodontic forces: up to 500 g, possibility of immediate loading, device removal, possibility to use in growing patients. The most widely used material was TiAl6V4; most of the surfaces were smooth; the most commonly used head type was the bracket; the most often produced length was the "short" one (8.0-9.9 mm), the most demanded diameter the "smaller" one (1.2-1.4 mms); six systems out of eleven had micro implants with "extra" and "standard" necks; only 3 systems out of eleven produced "non self drilling"devices; all the micro implants analysed were able to withstand orthodontic forces between 150 g and 350 g; all devices were suitable for "immediate loading"; all micro implants had to be removed; all micro implants could be used in growing patients. The comparative analysis showed that micro implants could be used as valid anchorage systems, if dental anchorage was insufficient either in qualitative terms (i.e. parodontal problems) or in quantitative terms (i.e. few dental elements remaining), and in all those situations of limited patient compliance. Copyright © 2010 Società Italiana di Ortodonzia SIDO. Published by Elsevier Srl. All rights reserved.
Mangano, Francesco; Raspanti, Mario; Maghaireh, Hassan; Mangano, Carlo
2017-12-17
Purpose . The aim of this scanning electron microscope (SEM) study was to investigate the interface between the bone and a novel nanostructured calcium-incorporated dental implant surface in humans. Methods . A dental implant (Anyridge ® , Megagen Implant Co., Gyeongbuk, South Korea) with a nanostructured calcium-incorporated surface (Xpeed ® , Megagen Implant Co., Gyeongbuk, South Korea), which had been placed a month earlier in a fully healed site of the posterior maxilla (#14) of a 48-year-old female patient, and which had been subjected to immediate functional loading, was removed after a traumatic injury. Despite the violent trauma that caused mobilization of the fixture, its surface appeared to be covered by a firmly attached, intact tissue; therefore, it was subjected to SEM examination. The implant surface of an unused nanostructured calcium-incorporated implant was also observed under SEM, as control. Results . The surface of the unused implant showed a highly-structured texture, carved by irregular, multi-scale hollows reminiscent of a fractal structure. It appeared perfectly clean and devoid of any contamination. The human specimen showed trabecular bone firmly anchored to the implant surface, bridging the screw threads and filling the spaces among them. Conclusions . Within the limits of this human histological report, the sample analyzed showed that the nanostructured calcium-incorporated surface was covered by new bone, one month after placement in the posterior maxilla, under an immediate functional loading protocol.
Longoni, Salvatore; Sartori, Matteo; Davide, Roberto
2004-06-01
An important aim of implant-supported prostheses is to achieve a passive fit of the framework with the abutments to limit the amount of stress transfer to the bone-implant interface. An efficient and standardized technique is proposed. A definitive screw-retained, implant-supported complete denture was fabricated for an immediately loaded provisional screw-retained implant-supported complete denture. Precise fit was achieved by the use of industrial titanium components and the passivity, by an intraoral luting sequence and laser welding.
MEYNARDI, F.; PASQUALINI, M.E.; ROSSI, F.; DAL CARLO, L.; NARDONE, M.; BAGGI, L.
2016-01-01
SUMMARY Purpose To assess the changes in bacterial profile along the transmucosal path of healing screws placed immediately after insertion of two-piece endosseus implants during the 4-month osseointegration phase, in absence of functional load. Materials and methods Two site-specific samples were collected at the peri-implant mucosa of the healing screws of 80 two-piece implants, for a total of 640 samples. Implants placement was performed following a single protocol with flapless technique, in order to limit bacterial contamination of the surgical site. Identical healing screws (5 mm diameter/4 mm height) were used for each of the 80 implants. During the 4 months of the study, the patients followed a standard oral care regimen with no special hygiene maneuvers at the collection sites. Results The present research documents that during the 4-month period prior to application of function load the bacterial profile of all sites exhibited a clear prevalence of cocci at the interface between implant neck and osteoalveolar crest margin. Conclusions A potentially pathogenic bacterial flora developed only along the peri-implant transmucosal path. PMID:28280528
Kolinski, Martin; Hess, Pablo; Leziy, Sonia; Friberg, Bertil; Bellucci, Gionata; Trisciuoglio, Davide; Wagner, Wilfried; Moergel, Maximilian; Pozzi, Alessandro; Wiltfang, Jörg; Behrens, Eleonore; Zechner, Werner; Vasak, Christoph; Weigl, Paul
2018-07-01
The aim of this interim analysis of a 5-year prospective multicenter study is to evaluate clinical and radiological performance of immediately provisionalized 3.0-mm-diameter tapered implants. Patients needing implant rehabilitation of maxillary lateral incisors or mandibular lateral and central incisors were treated with 3.0-mm-diameter implants placed in extraction or healed sites and immediately provisionalized. Clinical and radiographic examinations were performed at implant insertion, 6 months thereafter, and are ongoing. Marginal bone levels and changes, complications, the papilla, plaque, and bleeding indices, and the pink esthetic score (PES) were evaluated at each follow-up visit. Of 112 enrolled patients, 77 patients (91 implants) met the inclusion criteria. Seventy-one patients with 82 implants completed the 1-year follow-up. Three implants failed yielding a CSR of 96.7%. All failures occurred within the first 3 months after implant insertion. Marginal bone level changes from insertion to 6 months was - 0.57 ± 1.30 mm (n = 75) and from insertion to 12 months - 0.25 ± 1.38 mm (n = 72). Fifteen non-serious complications were recorded. Papilla index score and PES improved at the 1-year follow-up. Plaque formation and bleeding-on-probing showed no statistically significant differences between the 6-month and the 1-year visit. This 1-year analysis demonstrated high survival, stable bone levels, and healthy soft tissue with 3.0-mm-diameter implants. Narrow diameter implants are a safe and predictable treatment option in patients with limited bone volume and/or limited interdental space and eligible for immediate loading protocols.
Tetè, Stefano; Zizzari, Vincenzo; De Carlo, Alessandro; Sinjari, Bruna; Gherlone, Enrico
2012-01-01
Summary The purpose of this study is to evaluate macroscopic and microscopic appearance of a new implant design, with particular emphasis given to the type of prosthesis connection. Two dental implants of the same type (Torque Type®, WinSix®, BioSAFin. S.r.l. - Ancona, Italy), with sandblasted and acid etched surfaces (Micro Rough Surface®), but differing from each other for the prosthesis connection system, were examined by scanning electron microscope (SEM) analysis at different magnifications: TTI implant, with a hexagonal internal connection, and TTX implant, with a hexagonal external connection. SEM analysis showed that the Torque Type® implant is characterized by a truncated cone shape with tapered tips. The implant body showed a double loop thread and double pitch with blunt tips. For both types of connection, the implant neck was 0.7 mm in height with a 3% taper. This implant design may be able to guarantee osteotomic properties at the time of insertion in a surgical site suitably prepared, a facilitated screwing, thanks to the thread pitch and to the broad and deep draining grooves, thereby ensuring a good primary stability. The different connection design appears defined and precise, in order to ensure a good interface between the fixture and the prosthetic components. Therefore, this design appears to be particularly suitable in cases where a good primary stability is necessary and a precise coupling between endosseous and prosthetic components, as it allows an easy insertion of the fixture even in conditions of reduced bone availability, and in cases of immediately loaded full-arch rehabilitations. PMID:23087785
Tetè, Stefano; Zizzari, Vincenzo; De Carlo, Alessandro; Sinjari, Bruna; Gherlone, Enrico
2012-04-01
The purpose of this study is to evaluate macroscopic and microscopic appearance of a new implant design, with particular emphasis given to the type of prosthesis connection. Two dental implants of the same type (Torque Type(®), WinSix(®), BioSAFin. S.r.l. - Ancona, Italy), with sandblasted and acid etched surfaces (Micro Rough Surface(®)), but differing from each other for the prosthesis connection system, were examined by scanning electron microscope (SEM) analysis at different magnifications: TTI implant, with a hexagonal internal connection, and TTX implant, with a hexagonal external connection. SEM analysis showed that the Torque Type(®) implant is characterized by a truncated cone shape with tapered tips. The implant body showed a double loop thread and double pitch with blunt tips. For both types of connection, the implant neck was 0.7 mm in height with a 3% taper. This implant design may be able to guarantee osteotomic properties at the time of insertion in a surgical site suitably prepared, a facilitated screwing, thanks to the thread pitch and to the broad and deep draining grooves, thereby ensuring a good primary stability. The different connection design appears defined and precise, in order to ensure a good interface between the fixture and the prosthetic components. Therefore, this design appears to be particularly suitable in cases where a good primary stability is necessary and a precise coupling between endosseous and prosthetic components, as it allows an easy insertion of the fixture even in conditions of reduced bone availability, and in cases of immediately loaded full-arch rehabilitations.
[Design on tester of pull-out force for orthodontic micro implant].
Su, He; Wu, Pei; Wang, Huiyuan; Chen, Yan; Bao, Xuemei
2013-09-01
A special device for measuring the pull-out force of orthodontic micro implant was designed, which has the characteristics of simple construction and easy operation, and can be used to detect the pull-out-force of orthodontic micro implant. The tested data was stored and analyzed by a computer, and as the results, the pull-out-force curve, maximum pull-out force as well as average pull-out force were outputted, which was applied in analyzing or investigating the initial stability and immediate loading property of orthodontic micro implant.
Li, Haoyan; Liang, Yongqiang; Zheng, Qiang
2015-01-01
To evaluate correlations between marginal bone resorption and high insertion torque value (> 50 Ncm) of dental implants and to assess the significance of immediate and early/conventional loading of implants under a certain range torque value. Specific inclusion and exclusion criteria were used to retrieve eligible articles from Ovid, PubMed, and EBSCO up to December 2013. Screening of eligible studies, quality assessment, and data extraction were conducted in duplicate. The results were expressed as random/fixed-effects models using weighted mean differences for continuous outcomes with 95% confidence intervals. Initially, 154 articles were selected (11 from Ovid, 112 from PubMed, and 31 from EBSCO). After exclusion of duplicate articles and articles that did not meet the inclusion criteria, six clinical studies were selected. Assessment of P values revealed that correlations between marginal bone resorption and high insertion torque were not statistically significant and that there was no difference between immediately versus early/conventionally loaded implants under a certain range of torque. None of the meta-analyses revealed any statistically significant differences between high insertion torque and conventional insertion torque in terms of effects on marginal bone resorption.
Matin, Khalrul; Senpuku, Hidenobu; Hanada, Nobuhiro; Ozawa, Hidehiro; Ejiri, Sadakazu
2003-01-01
Difficulties relating to bone regeneration that complicate immediate implant placement include buccal and/or lingual fenestrations, primary anchorage of the implants, and the need for protection from functional loading during the osseointegration period. The objective of this pilot study was to evaluate bone regeneration by recombinant human bone morphogenetic protein-2 (rhBMP-2) around immediate implants placed in maxillary sockets in rats. A total of 16 cylindric 0.8 x 1.8-mm commercially pure, solid titanium Implants were placed immediately after gentle extraction of the maxillary first molar teeth of 8 male Wistar rats. The sockets were randomly divided into 3 groups: group 1 (n = 6) received rhBMP-2 with polylactic acid/polyglycolic acid copolymer-coated gelatin sponge carrier; group 2 (n = 5) received only the carrier; and group 3 (n = 5) received no grafting materials following placement The rats were euthanized at 90 days postsurgery for microscopic analysis. In group 1, the implant body remained submerged completely, including the coronal part, which was fully covered by a significant amount (30% of total height) of regenerated cortical bone, even though the implant could easily be pulled out by a tweezer at the time of placement. Close approximation between the implant surface and regenerated bone could also be detected, indicating good bone-to-implant contact. In contrast, only peri-implant bone regeneration occurred in group 2, and an approximate 0.3-mm coronal part of the implant remained exposed. When no grafting materials were used (group 3), almost one third of the total length of the implant was exfoliated out of the socket when no grafting materials were used. Based on previous study and data from 16 sockets of the present study, it could be concluded that rhBMP-2 facilitated the regeneration of bone around immediate implants. In particular, the bone covering the coronal part could have been regenerated shortly after surgery, which helped to maintain the implant body inside the socket during the integration period in rats.
Esposito, Marco; Trullenque-Eriksson, Anna; Blasone, Rodolfo; Malaguti, Giuliano; Gaffuri, Cristiano; Caneva, Marco; Minciarelli, Armando; Luongo, Giuseppe
To evaluate the safety and clinical effectiveness of a novel dental implant system (GENESIS Implant System, Keystone Dental, Massachusetts, USA) using another dental implant system by the same manufacturer as a control (PRIMA Implant System, Keystone Dental). A total of 53 patients requiring at least two single crowns had their sites randomised according to a split-mouth design to receive both implant systems at six centres. If implants could be placed with a torque superior to 40 Ncm they were to be loaded immediately with provisional crowns, otherwise after 3 months of submerged healing. Provisional crowns were replaced by definitive crowns 4 months after initial loading, when the follow-up period for the initial part of this study was completed. Outcome measures were crown/implant failures, complications, pink esthetic score (PES), peri-implant marginal bone level changes, plaque score, marginal bleeding, patients and preference of the clinician. In total 53 PRIMA and 53 GENESIS implants were placed. Three patients dropped out but all of the remaining patients were followed up to 4-months post-loading. No PRIMA implant failed whereas four GENESIS implants failed. Only two complications were reported for PRIMA implants. There were no statistically significant differences for crown/implant failures (difference in proportions = 0.080; P (McNemar test) = 0.125) and complications (difference in proportions = -0.04; P (McNemar test) = 0.500) between the implant systems. There were no differences at 4-months post-loading for plaque (difference = -0.54, 95% CI: -3.01 to 1.93; P (Paired t-test) = 0.660), marginal bleeding (difference = -3.8, 95% CI: -7.63 to 0.019; P (Paired t-test) = 0.051), PES (difference = 0.47, 95% CI: -0.56 to 1.50; P (Paired t-test) = 0.365) and marginal bone level changes (difference in mm = -0.04, 95% CI: -0.33 to 0.26; P (Paired t-test) = 0.795). The majority of the patients (46) had no preference regarding the two implant systems evaluated. Three operators preferred GENESIS implants, two had no preference and one preferred GENESIS in medium and soft bone and PRIMA in hard bone. No statistically significant differences were observed between the systems' implant types, although four GENESIS implants failed versus none of the PRIMA type. Longer follow-ups of wider patient populations are needed to better understand whether there is an effective advantage with one of the two implant designs. Conflict-of-interest statement: This research project was originally funded by Keystone Italia, Dental spa (Verona, Italy), the manufacturer of the implants evaluated in this investigation. However, when Keystone Italia received the data of the present manuscript, they refused to honour the financial agreement for the present publication. Therefore, no further follow-ups of this trial will be considered. A legal action was initiated against Keystone Italia. The data belonged to the authors and by no means was the manufacturer allowed to interfere with the conduct of the trial or the publication of the results.
Determination of the frictional coefficient of the implant-antler interface: experimental approach.
Hasan, Istabrak; Keilig, Ludger; Staat, Manfred; Wahl, Gerhard; Bourauel, Christoph
2012-10-01
The similar bone structure of reindeer antler to human bone permits studying the osseointegration of dental implants in the jawbone. As the friction is one of the major factors that have a significant influence on the initial stability of immediately loaded dental implants, it is essential to define the frictional coefficient of the implant-antler interface. In this study, the kinetic frictional forces at the implant-antler interface were measured experimentally using an optomechanical setup and a stepping motor controller under different axial loads and sliding velocities. The corresponding mean values of the static and kinetic frictional coefficients were within the range of 0.5-0.7 and 0.3-0.5, respectively. An increase in the frictional forces with increasing applied axial loads was registered. The measurements showed an evidence of a decrease in the magnitude of the frictional coefficient with increasing sliding velocity. The results of this study provide a considerable assessment to clarify the suitable frictional coefficient to be used in the finite element contact analysis of antler specimens.
Functional adaptation of the masticatory system to implant-supported mandibular overdentures.
Giannakopoulos, Nikolaos Nikitas; Corteville, Frédéric; Kappel, Stefanie; Rammelsberg, Peter; Schindler, Hans Jürgen; Eberhard, Lydia
2017-05-01
The purpose of this study was to investigate the adaptation behavior of the stomatognathic system after immediate loading (24 to 72 h after surgery) of two implants supporting mandibular overdentures, assessed on insertion and three months later. The study hypothesis was that insertion of the overdentures would significantly change masticatory performance and muscle activity at both times. Thirty subjects (nine female, mean age 69.64 ± 11.81 years; 21 male, mean age 68.67 ± 7.41 years) who participated in a randomized clinical trial were included in the study. Each patient was examined three times: (i) at baseline, after already having worn new dentures for three months (T1); (ii) immediately after insertion of the overdentures on the implants (T2); and (iii) after an adaptation period of three months (T3). Examination comprised assessment of masticatory performance with artificial test food (Optocal), and simultaneous bilateral surface EMG recording of the masseter and anterior temporalis muscles. Particle-size distribution (representative value X 50 ), maximum muscle contraction (MVC), and total muscle work (TMW; area under the curve) were compared by use of repeated-measures analysis of variance (ANOVA). At T3, all measured variables (i.e., masticatory performance and muscle activity) were significantly different from those at T1. At T2, no significant changes were observed. The study hypothesis had to be rejected for T2 but accepted for T3. Functional rehabilitation (in terms of masticatory performance and masticatory muscle activity) does not occur immediately after immediate loading of two implants with mandibular overdentures, but requires a significant time for functional improvement. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Penarrocha-Diago, María; Zaragozí-Alonso, Regino; Soto-Penaloza, David; on behalf of the Ticare Consensus, Meeting
2017-01-01
Objectives The present consensus report critically evaluates the scientific evidence based on a comprehensive systematic review of the All-On-4 treatment concept, focusing primarily on the treatment indications, surgical procedures and prosthetic protocols, and secondarily on the mechanical and biological complications involved. Material and Methods A systematic review was made in advance of the meeting. Consensus statements, treatment guidelines and recommendations for future research were based on within-group as well as plenary debates and discussions of the systematic review. Results The main indication of All-On-4 standard care is an atrophic maxilla or mandible, with or without remnant hopeless tooth. in ASA I or II patients. This surgical-prosthetic protocol seems efficient, safe and effective in the case of Cawood & Howell class IV, V and VI. It is necessary for the implant to have had an insertion torque of over 35 Ncm for immediate loading. The provisional prosthesis should provide rigidity, being non-flexible in order to avoid micro-movements, and should be strong enough to not fracture. Balanced occlusion without interferences is required, ensuring very gentle dynamic movements. The design of the definitive prosthesis must be cleanable and biomechanically adjusted to the implant position and individual characteristics of each patient. A non-concave acrylic base resting over soft tissue is recommended, facilitating hygiene. Regarding occlusion, a group guide should be made, taking into account whether the antagonist is not a removable complete denture. In that case, bi-balanced occlusion should be assessed. Prosthetic complications occur as a result of fractures of the provisional acrylic prostheses. These problems in turn can be resolved by repair through relining or fixing. The most frequent biological complication is the loss of at least one implant, while the second most frequent complication is the development of peri-implantitis and mucositis. Conclusions In the treatment of atrophy for full-arch implant supported restorations it is considered that four implants suffice for immediate loading and the final prosthesis, even when there is available bone between the mental foramina or maxillary sinuses. The weakness of the quality of the available evidence indicates that further studies are needed, involving an appropriate design and with adequate follow-up in All-On-4 standard care to confirm the present results mainly in relation to survival rates and complications. Key words:Atrophic jaw, All-on-4, immediate implant loading, edentulous mandible, edentulous maxilla, tilted implant, implant failure, dental implants. PMID:28512551
Penarrocha-Diago, Miguel; Penarrocha-Diago, María; Zaragozí-Alonso, Regino; Soto-Penaloza, David; On Behalf Of The Ticare Consensus, Meeting
2017-05-01
The present consensus report critically evaluates the scientific evidence based on a comprehensive systematic review of the All-On-4 treatment concept, focusing primarily on the treatment indications, surgical procedures and prosthetic protocols, and secondarily on the mechanical and biological complications involved. A systematic review was made in advance of the meeting. Consensus statements, treatment guidelines and recommendations for future research were based on within-group as well as plenary debates and discussions of the systematic review. The main indication of All-On-4 standard care is an atrophic maxilla or mandible, with or without remnant hopeless tooth. in ASA I or II patients. This surgical-prosthetic protocol seems efficient, safe and effective in the case of Cawood & Howell class IV, V and VI. It is necessary for the implant to have had an insertion torque of over 35 Ncm for immediate loading. The provisional prosthesis should provide rigidity, being non-flexible in order to avoid micro-movements, and should be strong enough to not fracture. Balanced occlusion without interferences is required, ensuring very gentle dynamic movements. The design of the definitive prosthesis must be cleanable and biomechanically adjusted to the implant position and individual characteristics of each patient. A non-concave acrylic base resting over soft tissue is recommended, facilitating hygiene. Regarding occlusion, a group guide should be made, taking into account whether the antagonist is not a removable complete denture. In that case, bi-balanced occlusion should be assessed. Prosthetic complications occur as a result of fractures of the provisional acrylic prostheses. These problems in turn can be resolved by repair through relining or fixing. The most frequent biological complication is the loss of at least one implant, while the second most frequent complication is the development of peri-implantitis and mucositis. In the treatment of atrophy for full-arch implant supported restorations it is considered that four implants suffice for immediate loading and the final prosthesis, even when there is available bone between the mental foramina or maxillary sinuses. The weakness of the quality of the available evidence indicates that further studies are needed, involving an appropriate design and with adequate follow-up in All-On-4 standard care to confirm the present results mainly in relation to survival rates and complications. Key words: Atrophic jaw, All-on-4, immediate implant loading, edentulous mandible, edentulous maxilla, tilted implant, implant failure, dental implants.
Capelli, Matteo; Testori, Tiziano; Galli, Fabio; Zuffetti, Francesco; Motroni, Alessandro; Weinstein, Roberto; Del Fabbro, Massimo
2013-12-01
The aim of this study is to investigate contour changes around immediate implants in fresh extraction sockets when different grafting procedures are performed, based on the distance between the external implant collar and the bony surface on the buccal plate (I-BP). A secondary aim is to assess the esthetic outcome via the implant esthetic score (IAS). This prospective cohort study was performed in three centers. Suitable patients to undergo implant placement in fresh extraction sockets were selected. Periodontal biotype, horizontal and vertical peri-implant bone defects, and dehiscences were assessed. Depending on I-BP, two types of grafting procedures were performed. In group A (I-BP <4 mm), only the peri-implant gap was grafted during the surgical phase (internal grafting [IG]), whereas group B (I-BP ≥ 4 mm) received both internal and external grafting (IEG). Master casts of the sites, made before implant placement and after 1 year of loading, were optically scanned. A computerized analysis of the contour changes at the involved sites was performed by superimposing the scanned models. A total of 20 patients (eight males and 12 females) were recruited, and 20 non-submerged implants were placed in fresh extraction sockets. No implant failed during the observation period. The mean follow-up was 25 months (range: 12 to 37 months). After 1 year of loading, group A showed a slight decrease in mean buccal volume, whereas group B had an increase in volume (P = 0.02). IAS was higher for group B than group A. When implants are placed immediately after tooth extraction, I-BP may represent a useful diagnostic parameter in choosing the most appropriate grafting procedure (IG versus IEG). In clinical cases in which the distance between implant surface and the buccal plate is <4 mm, the combination of internal and external grafting (IEG) is recommended to maintain the volume and the contour of the ridge and achieve a successful esthetic outcome.
Kronstrom, Mats; Davis, Ben; Loney, Robert; Gerrow, Jack; Hollender, Lars
2014-06-01
The objective of the study was to evaluate and compare treatments with mandibular overdentures supported by one or two immediately placed implants 3 years after loading. Thirty-six edentulous subjects were eligible for inclusion. Using a random sampling system, one or two implants were placed in the mandible. Separate ball attachments were connected to the implants, and the denture was relined and delivered the day of surgery with the retentive components incorporated in the denture base. At the follow-up examinations peri-implant bone levels, implant and denture stability/retention, and need for maintenance and adjustments were evaluated. Moreover, the OHIP-EDENT questionnaire was used to measure patient satisfaction. Nineteen subjects (10 men and 9 women) with a mean age of 56 years were available for the 3-year follow-up examination. The group with 1 implant (Group 1) consisted of 11 subjects (5 women and 6 men) while the remaining 8 (5 women and 3 men) belonged to Group2. Nine subjects had been excluded during the first year due to failing implants, 6 had moved, 1 had died, and 1 reported severe illness. No implant failures between the 12-and 36 month follow-up were observed. The mean peri-implant bone change was.86 mm and the Implant Stability Quotient showed only minor changes with no significant difference between the groups when compared with the 12-month follow-up. Patient satisfaction scores increased significantly when compared with the baseline values and continued to be high for both groups and need for denture maintenance was low. No significant differences were found between subjects in the two groups with respect to implant survival and peri implant bone loss, and patient satisfaction scores continued to be high for both groups. Need for denture maintenance was low in both groups. © 2012 Wiley Periodicals, Inc.
Aunmeungtong, Weerapan; Kumchai, Thongnard; Strietzel, Frank P; Reichart, Peter A; Khongkhunthian, Pathawee
2017-04-01
Dental implant-retained overdentures have been chosen as the treatment of choice for complete mandibular removable dentures. Dental implants, such as mini dental implants, and components for retaining overdentures, are commercially available. However, comparative clinical studies comparing mini dental implants and conventional dental implants using different attachment for implant-retained overdentures have not been well documented. To compare the clinical outcomes of using two mini dental implants with Equator ® attachments, four mini dental implants with Equator attachments, or two conventional dental implants with ball attachments, by means of a randomized clinical trial. Sixty patients received implant-retained mandibular overdentures in the interforaminal region. The patients were divided into three groups. In Groups 1 and 2, two and four mini dental implants, respectively, were placed and immediately loaded by overdentures, using Equator ® attachments. In Group 3, conventional implants were placed. After osseointegration, the implants were loaded by overdentures, using ball attachments. The study distribution was randomized and double-blinded. Outcome measures included changes in radiological peri-implant bone level from surgery to 12 months postinsertion, prosthodontic complications and patient satisfaction. The cumulative survival rate in the three clinical groups after one year was 100%. There was no significant difference (p < 0.05) in clinical results regarding the number (two or four) of mini dental implants with Equator attachments. However, there was a significant difference in marginal bone loss and patient satisfaction between those receiving mini dental implants with Equator attachments and conventional dental implants with ball attachments. The marginal bone resorption in Group 3 was significantly higher than in Groups 1 and 2 (p < 0.05); there were no significant differences between Groups 1 and 2. There was no significant difference in patient satisfaction between Groups 1 and 2 but it was significantly higher than that in Group3 (p < 0.05). Two and four mini dental implants can be immediately used successfully for retaining lower complete dentures, as shown after a 1-year follow up. © 2016 Wiley Periodicals, Inc.
Zirconia-implant-supported all-ceramic crowns withstand long-term load: a pilot investigation.
Kohal, Ralf-J; Klaus, Gerold; Strub, Jörg R
2006-10-01
The purpose of this pilot investigation was to test whether zirconia implants restored with different all-ceramic crowns would fulfill the biomechanical requirements for clinical use. Therefore, all-ceramic Empress-1 and Procera crowns were cemented on zirconia implants and exposed to the artificial mouth. Afterwards, the fracture strength of the all-ceramic implant-crown systems was evaluated. Conventional titanium implants restored with porcelain-fused-to-metal (PFM) crowns served as controls. Sixteen titanium implants with 16 PFM crowns and 32 zirconia implants with 16 Empress-1 crowns and 16 Procera crowns each--i.e., three implant-crown groups--were used in this investigation. The titanium implants were fabricated using the ReImplant system and the zirconia implants using the Celay system. The upper left central incisor served as a model for the fabrication of the implants and the crowns. Eight samples of each group were submitted to a long-term load test in the artificial mouth (1.2 million chewing cycles). Subsequently, a fracture strength test was performed with seven of the eight crowns. The remaining eight samples of each group were not submitted to the long-term load in the artificial mouth but were fracture-tested immediately. One loaded and one unloaded sample of each group were evaluated regarding the marginal fit of the crowns. All test samples survived the exposure to the artificial mouth. Three Empress-1 crowns showed cracks in the area of the loading steatite ball. The values for the fracture load in the titanium implant-PFM crown group without artificial loading ranged between 420 and 610 N (mean: 531.4 N), between 460 and 570 N (mean: 512.9 N) in the Empress-1 crown group, and in the Procera crown group the values were between 475 and 700 N (mean: 575.7 N) when not loaded artificially. The results when the specimens were loaded artificially with 1.2 million cycles were as follows: the titanium implant-PFM crowns fractured between 440 and 950 N (mean: 668.6 N), the Empress-1 crowns between 290 and 550 N (mean: 410.7 N), and the Procera crowns between 450 and 725 N (mean: 555.5 N). No statistically significant differences could be found among the groups without artificial load. The fracture values for the PFM and the Procera crowns after artificial loading were statistically significantly higher than that for the loaded Empress-1 crowns. There was no significant difference between the PFM crown group and the Procera group. Within the limits of this pilot investigation, it seems that zirconia implants restored with the Procera crowns possibly fulfill the biomechanical requirements for anterior teeth. However, further investigations with larger sample sizes have to confirm these preliminary results. As three Empress-1 crowns showed crack development in the loading area of the steatite balls in the artificial mouth, their clinical use on zirconia implants has to be questioned.
Effects of Percutaneous LVAD Support on Right Ventricular Load and Adaptation.
Yourshaw, Jeffrey P; Mishra, Prabodh; Armstrong, M Christopher; Ramu, Bhavadharini; Craig, Michael L; Van Bakel, Adrian B; Steinberg, Daniel H; DiSalvo, Thomas G; Tedford, Ryan J; Houston, Brian A
2018-04-30
Both operative and hemodynamic mechanisms have been implicated in right heart failure (RHF) following surgical left ventricular assist device (LVAD) implantation. We investigated the effects of percutaneous LVAD (pLVAD; Impella®, Abiomed) support on right ventricular (RV) load and adaptation. We reviewed all patients receiving a pLVAD for cardiogenic shock at our institution between July 2014 and April 2017, including only those with pre- and post-pLVAD invasive hemodynamic measurements. Hemodynamic data was recorded immediately prior to pLVAD implantation and up to 96 h post-implantation. Twenty-five patients were included. Cardiac output increased progressively during pLVAD support. PAWP improved early post-pLVAD but did not further improve during continued support. Markers of RV adaptation (right ventricular stroke work index, right atrial pressure (RAP), and RAP to pulmonary artery wedge pressure ratio (RAP:PAWP)) were unchanged acutely implant but progressively improved during continued pLVAD support. Total RV load (pulmonary effective arterial elastance; E A ) and resistive RV load (pulmonary vascular resistance; PVR) both declined progressively. The relationship between RV load and RV adaptation (E A /RAP and E A /RAP:PAWP) was constant throughout. Median vasoactive-inotrope score declined after pLVAD placement and continued to decline throughout support. Percutaneous LVAD support in patients with cardiogenic shock did not acutely worsen RV adaptation, in contrast to previously described hemodynamic effects of surgically implanted durable LVADs. Further, RV load progressively declined during support, and the noted RV adaptation improvement was load-dependent as depicted by constant E A /RA and E A /RAP:PAWP relationships. These findings further implicate the operative changes associated with surgical LVAD implantation in early RHF following durable LVAD.
2017-01-01
Purpose To retrospectively evaluate the relationship between the vertical position of the implant-abutment interface and marginal bone loss over 3 years using radiological analysis. Methods In total, 286 implant surfaces of 143 implants from 61 patients were analyzed. Panoramic radiographic images were taken immediately after implant installation and at 6, 12, and 36 months after loading. The implants were classified into 3 groups based on the vertical position of the implant-abutment interface: group A (above bone level), group B (at bone level), and group C (below bone level). The radiographs were analyzed by a single examiner. Results Changes in marginal bone levels of 0.99±1.45, 1.13±0.91, and 1.76±0.78 mm were observed at 36 months after loading in groups A, B, and C, respectively, and bone loss was significantly greater in group C than in groups A and B. Conclusions The vertical position of the implant-abutment interface may affect marginal bone level change. Marginal bone loss was significantly greater in cases where the implant-abutment interface was positioned below the marginal bone. Further long-term study is required to validate our results. PMID:28861287
Cosola, Saverio; Marconcini, Simone; Giammarinaro, Enrica; Poli, Gian L; Covani, Ugo; Barone, Antonio
2018-04-16
Patient-centred outcomes are being given great attention by the dental scientific community. The Oral Health Impact Profile -14 questionnaire (OHIP-14) has been introduced to address patients' success criteria when describing the impact of oral rehabilitations on quality of life (OHrQoL). Thirty-five patients wearing a full-arch implant-prosthesis being in place between 4 and 6 years before this analysis were considered eligible and then enrolled in the present retrospective study. According to their prosthetic anamnesis, two groups were defined: delayed loading group (IL-group) and immediate loading group (IL-group). At the moment of analysis, clinical and radiographic parameters were collected, and patients were asked to complete the Oral Health Impact Profile -14 questionnaire (OHIP-14) in order to measure their OHrQoL. Independent t-test showed total OHIP-14 scores to be not significantly different between groups; however, the domains "Functional limitation" and "physical disability" resulted significantly higher in patients within the DL-group. On the contrary, social disability was higher in the IL-group. When the comparison was performed taking sex into account, no significant differences between groups were highlighted. Instead, the stratification for years of follow-up led to significant evidences. When the follow-up was shorter (less-than-5 years), the functional limitation reported scores were higher. Within the limitations of this study, the analysis supports the absence of significant differences between immediate loading and delayed loading full-arch protocol in term of clinical, radiological parameters and OHrQoL.
Raes, Stefanie; Raes, Filiep; Cooper, Lyndon; Giner Tarrida, Luis; Vervaeke, Stijn; Cosyn, Jan; De Bruyn, Hugo
2017-06-01
The impact of single implants on oral health-related quality of life (OHRQoL) is scarcely investigated, especially when combined with immediate placement and loading in extraction sockets. The aim was to describe prospectively the changes of OHRQoL with single implants placed in the esthetic zone in healed ridges or in extraction sockets after 5 years. Ninety-six patients, enrolled at three clinical centers, received 102 single implants placed in a healed ridge (n = 54 implants/50 patients) or in extraction sockets (n = 48 implants/46 patients). Implants were immediately provisionalized, and permanent crowns were cemented after 12 weeks. Oral health impact profile questionnaires (OHIP-14) were completed before surgery, after 1 (provisional crown), 6 (permanent crown), 12 and 60 months, respectively. The overall OHIP-14 score pertains to seven domains with two items each and was assessed on a Likert scale of 0-4 (0 = never and 4 = very often). The evolution of the total OHIP-14 score and changes within all OHIP domains over time and between groups were assessed with a linear mixed-effect model analysis. After 5 years, overall implant survival was 98%. The total OHIP-14 score for both groups combined decreased from 0.50 at baseline to 0.17 at 6 months (P < 0.001), indicative of improvement. For both groups, this remained stable up to 5 years (P = 0.41). However, after 5 years, the total OHIP-14 score revealed a statistically significantly higher improvement in the healed group compared with the extraction group (P = 0.027). Missing a single tooth in the maxillary esthetic zone leads to limited OHRQoL problems as reflected by a low overall OHIP score. However, OHRQoL improves less in the extraction group, reflecting that replacing a missing tooth is perceived as more beneficial than replacing a present tooth. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Balshi, Thomas J; Wolfinger, Glenn J; Alfano, Stephen G; Croce, J Neil Della; Balshi, Stephen F
2015-04-01
The purpose of this patient report is to accurately portray the clinical experience of treating an active bulimic patient by employing an immediately loaded dental implant protocol to provide the patient with an expedited esthetic and functional result. Implementation of a psychometric component statistically quantifies the psychological effects of the oral rehabilitation. A 34-year-old woman presented with severe dental perimolysis (erosion) resulting from a 28-year history of bulimic behaviors. Clinical and radiographic evaluation of the existing dentition indicated advanced dental erosion and previous restoration attempts in a state of failure. The patient's existing teeth were extracted and treated with full maxillary and mandibular implant-supported prostheses, following the Teeth in a Day® (TIAD) immediate functional loading protocol. Psychometric assessment was conducted through administration of a 20-item questionnaire, as seen in previous literature. Radiographic and clinical analysis suggested all implant fixtures to be viable and accompanied by normal levels of alveolar bone 7 months into treatment. Questionnaire results at the new-patient presentation (T1) resulted in a composite score of 4.0 (SD = 2.9; P = 0.004), indicating severe body-image dysphoria. At 3 months postoperative (T2), the questionnaire score was 0.4 (SD = -1.7; P = 0.09). The final psychometric questionnaire at 7 months (T3) resulted in a score of 0.5 (SD = -1.5; P = 0.12). The patient was followed for a total of 7 years following implant placement. In this patient report, oral rehabilitation using the TIAD protocol provided an expedited and predictable alternative method for restoring functional abilities, esthetics, and self-esteem to a severely depressed bulimic patient. Psychometrically, at the postoperative (T2) and final testing period (T3), the patient's body image profile was no longer considered to be significantly different from established normative values.
Atluri, Pavan; Fairman, Alexander S.; MacArthur, John W.; Goldstone, Andrew B.; Cohen, Jeffrey E.; Howard, Jessica L.; Zalewski, Christyna M.; Shudo, Yasuhiro; Woo, Y. Joseph
2014-01-01
Background Continuous flow left ventricular assist devices (CF LVAD) are being implanted with increasing frequency for end-stage heart failure. At the time of LVAD implant, a large proportion of patients have pulmonary hypertension, right ventricular (RV) dysfunction, and tricuspid regurgitation (TR). RV dysfunction and TR can exacerbate renal dysfunction, hepatic dysfunction, coagulopathy, edema, and even prohibit isolated LVAD implant. Repairing TR mandates increased cardiopulmonary bypass time and bicaval cannulation, which should be reserved for the time of orthotopic heart transplantation. We hypothesized that CF LVAD implant would improve pulmonary artery pressures, enhance RV function, and minimize TR, obviating need for surgical tricuspid repair. Methods One hundred fourteen continuous flow LVADs implanted from 2005 through 2011 at a single center, with medical management of functional TR, were retrospectively analyzed. Pulmonary artery pressures were measured immediately prior to and following LVAD implant. RV function and TR were graded according to standard echocardiographic criteria, prior to, immediately following, and long-term following LVAD. Results There was a significant improvement in post-VAD mean pulmonary arterial pressures (26.6 ± 4.9 vs. 30.2 ± 7.4 mmHg, p = 0.008) with equivalent loading pressures (CVP = 12.0 ± 4.0 vs. 12.1 ± 5.1 p = NS). RV function significantly improved, as noted by right ventricular stroke work index (7.04 ± 2.60 vs. 6.05 ± 2.54, p = 0.02). There was an immediate improvement in TR grade and RV function following LVAD implant, which was sustained long term. Conclusion Continuous flow LVAD implant improves pulmonary hypertension, RV function, and tricuspid regurgitation. TR may be managed nonoperatively during CF LVAD implant. PMID:24118109
Accelerated treatment protocols: full arch treatment with interim and definitive prostheses.
Drago, Carl
2012-01-01
With the advent of titanium, root form implants and osseointegration, dental treatment has undergone a metamorphosis in recent years. These new techniques enable dentists to provide anchorage for various kinds of prostheses that improve masticatory function, esthetics, and comfort for patients. Implant treatment protocols have been improved relative to implant macro- and micro-geometries, surgical and prosthetic components, and treatment times. Over the past 20 years, immediate occlusal function (also known as loading) has been established as a predictable treatment modality, provided certain specific criteria are met. In many cases, edentulous patients, crippled by the loss of their teeth, can undergo outpatient surgical and prosthetic procedures and return to a masticatory function that is near normal--sometimes after only one day of surgical and prosthetic treatment. This treatment option is also available for patients with advanced, generalized periodontal disease. Computer-assisted design/Computer-assisted manufacturing (CAD/CAM) has transformed how dental prostheses are made, offering improved accuracy, longevity, and biocompatibility; along with reduced labor costs and fewer complications than casting technologies. This article reviews the principles associated with immediate occlusal loading and illustrates one specific accelerated prosthodontic treatment protocol used to treat edentulous and partially edentulous patients with interim and definitive prostheses.
Babbush, Charles A
2012-06-01
Patient well-being is always the goal of rehabilitation of edentulism; however, evaluations of treatment success often overlook the patient's subjective feelings about comfort, function, speech, social image, social inhibitions, psychological discomfort, and/or disabilities. The purpose of this study was to assess these patient responses using an oral health questionnaire. To assess such feelings, a self-administered 20-question multiple-choice patient-reported Edentulous Patient Impact Questionnaire was developed, based upon the previously validated Oral Health Impact Profile patient-assessment tool. Responses were solicited from randomly selected patients treated with an implant-supported, fixed, immediately loaded full arch prosthesis. The questionnaires were completed by 250 patients. Of the respondents, 95% described themselves as being either extremely satisfied (74%) or satisfied (21%) with their new teeth, and 98% said they would definitely recommend similar treatment (88%) or consider recommending it (10%) to a friend or colleague. Based upon an oral health impact survey completed by 250 patients treated with full-arch implant-supported, immediately loaded fixed dental prostheses, it appears that patient satisfaction is high and that treated patients would generally be willing to recommend this treatment to others.
Mazaro, José Vitor Quinelli; Filho, Humberto Gennari; Vedovatto, Eduardo; Pellizzer, Eduardo Piza; Rezende, Maria Cristina Rosifini Alves; Zavanelli, Adriana Cristina
2011-11-01
The purposes of this study were to photoelastically measure the biomechanical behavior of 4 implants retaining different cantilevered bar mandibular overdenture designs and to compare a fixed partial denture (FPD). A photoelastic model of a human edentulous mandible was fabricated, which contained 4 screw-type implants (3.75 × 10 mm) embedded in the parasymphyseal area. An FPD and 3 overdenture designs with the following attachments were evaluated: 3 plastic Hader clips, 1 Hader clip with 2 posterior resilient cap attachments, and 3 ball/O-ring attachments. Vertical occlusal forces of 100 N were applied between the central incisor and unilaterally to the right and left second premolars and second molars. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. The results showed that the anterior loading, the overdenture with 3 plastic Hader clips, displayed the largest stress concentration at the medium implant. With premolar loading, the FPD and overdenture with 3 plastic Hader clips displayed the highest stresses to the ipsilateral terminal implant. With molar loading, the overdenture with 3 ball/O-ring attachments displayed the most uniform stress distribution in the posterior edentulous ridge, with less overloading in the terminal implant. It was concluded that vertical forces applied to the bar-clip overdenture and FPD created immediate stress patterns of greater magnitude and concentration on the ipsilateral implants, whereas the ball/O-ring attachments transferred minimal stress to the implants. The increased cantilever in the FPD caused the highest stresses to the terminal implant.
Trisi, Paolo; Berardi, Davide; Paolantonio, Michele; Spoto, Giuseppe; D'Addona, Antonio; Perfetti, Giorgio
2013-05-01
Between implants and peri-implant bone, there should be a minimum gap, without micromotions over a threshold, which could cause resorption and fibrosis. The higher the implant insertion torque, the higher will be the initial stability. The aim was to evaluate in vitro the correlation between micromotions and insertion torque of implants in bone of different densities. The test was performed on bovine bone of hard, medium, and soft density: 150 implants were used, 10 for each torque (20, 35, 45, 70, and 100 N/cm). Samples were fixed on a loading device. On each sample, we applied a 25-N horizontal force. Insertion torque and micromotions are statistically correlated. In soft bone with an insertion force of 20 and 35 N/cm, the micromotion resulted significantly over the risk threshold, which was not found with an insertion force of 45 and 70 N/cm and in hard and medium bones with any insertion torque. The increase in insertion torque reduces the amount of micromotions between implant and bone. Therefore, the immediate loading may be considered a valid therapeutic choice, even in low-density bone, as long as at least 45 N/cm of insertion torque is reached.
Bramanti, Ennio; Norcia, Antonio; Cicciù, Marco; Matacena, Giada; Cervino, Gabriele; Troiano, Giuseppe; Zhurakivska, Khrystyna; Laino, Luigi
2018-06-01
The aim of this randomized controlled trial was to evaluate the survival rate, the marginal bone level, and the aesthetic outcome; at 3 years' follow-up, of dental implants placed into a high-esthetic aesthetic zone by comparing 2 techniques of postextraction implant with immediate loading: the socket shied technique and the conventional insertion technique.Several clinical studies suggested that the avulsion of a dental element causes dimensional alterations of both soft and hard tissues at the postextractive site. To increase the aesthetic outcomes, the "socket-shield technique" has been proposed. This method involves maintaining the vestibular root portion and immediate insertion of the dental implant in close proximity to the root.Patients enrolled in this study were randomized to receive a postextraction implant in the aesthetic zone, either with the socket shied technique or with the conventional insertion technique. Implant survival, marginal bone level, and the pink aesthetic score were the outcomes evaluated.Implant survival rate was 100% in both the groups at 3 years. Implants inserted with the socket shield technique showed better values of both marginal bone level and pink aesthetic score (P < 0.05).Although such preliminary results need to be further confirmed, the socket shield technique seems to be a safe surgical technique that allows an implant rehabilitation characterized by better aesthetic outcomes.
Maló, Paulo; Friberg, Bertil; Polizzi, Giovanni; Gualini, Federico; Vighagen, Torbjörn; Rangert, Bo
2003-01-01
Immediate/early implant function means great benefits for patients and therapists because treatment time and cost can be substantially reduced. This concept has become an accepted alternative for complete arch fixed restorations in the mandible, and clinical documentation is emerging for other indications. The purpose of this prospective clinical multicenter study was to evaluate the outcome of implants placed in incisor, canine, and premolar regions in maxillas or mandibles. Implants were loaded with provisional crowns and bridges on the same day or within a few days and were followed up for 1 year during function. Four centers treated 76 patients each in need of an implant-retained prosthesis in the anterior and premolar regions in the maxilla or mandible. A total of 116 titanium implants with machined surfaces (Brånemark System , Nobel Biocare AB, Gothenburg, Sweden) were placed: 74 in maxillas and 42 in mandibles. Eighty-seven prostheses were made, of which 63 were single crowns and 24 were bridges (supported by 53 splinted implants). Twenty-two implants in 14 patients were placed in fresh extraction sites. The goal with the preparation and insertion technique was to achieve good primary implant stability and a minimum implant insertion torque of 30 Ncm before the implant was completely seated. The occlusion was adjusted to eliminate direct contact with the provisional prostheses. After 6 months, the patients received their permanent prostheses. Sixty-seven patients were followed for 1 year. Five implants were lost in five patients, three in the maxilla and two in the mandible. Four of the lost implants were single-tooth replacements and one was splinted. The cumulative survival rate (CSR) was 95.7% for all implants after 1 year and 93.7% and 98.1% for single-tooth and splinted implants, respectively. There were no implant losses in the extraction sites. The CSR of 96% at 1 year indicates that immediate function of Brånemark System implants placed in incisor to premolar regions in both jaws is a viable concept. More failures occurred with single-tooth replacements (6.3%) than with splinted implants (1.9%).
Gehrke, Sergio Alexandre; da Silva, Ulisses Tavares; Del Fabbro, Massimo
2015-12-01
The purpose of this study was to assess implant stability in relation to implant design (conical vs. semiconical and wide-pitch vs narrow-pitch) using resonance frequency analysis. Twenty patients with bilateral edentulous maxillary premolar region were selected. In one hemiarch, conical implants with wide pitch (group 1) were installed; in the other hemiarch, semiconical implants with narrow pitch were installed (group 2). The implant allocation was randomized. The implant stability quotient (ISQ) was measured by resonance frequency analysis immediately following implant placement to assess primary stability (time 1) and at 90 days after placement (time 2). In group 1, the mean and standard deviation ISQ for time 1 was 65.8 ± 6.22 (95% confidence interval [CI], 55 to 80), and for time 2, it was 68.0 ± 5.52 (95% CI, 57 to 77). In group 2, the mean and standard deviation ISQ was 63.6 ± 5.95 (95% CI, 52 to 78) for time 1 and 67.0 ± 5.71 (95% CI, 58 to 78) for time 2. The statistical analysis demonstrated significant difference in the ISQ values between groups at time 1 (P = .007) and no statistical difference at time 2 (P = .54). The greater primary stability of conical implants with wide pitch compared with semiconical implants with narrow pitch might suggest a preference for the former in case of the adoption of immediate or early loading protocols.
Advances in surfaces and osseointegration in implantology. Biomimetic surfaces
Albertini, Matteo; Fernandez-Yague, Marc; Lázaro, Pedro; Herrero-Climent, Mariano; Bullon, Pedro; Gil, Francisco-Javier
2015-01-01
The present work is a revision of the processes occurring in osseointegration of titanium dental implants according to different types of surfaces -namely, polished surfaces, rough surfaces obtained from subtraction methods, as well as the new hydroxyapatite biomimetic surfaces obtained from thermochemical processes. Hydroxyapatite’s high plasma-projection temperatures have proven to prevent the formation of crystalline apatite on the titanium dental implant, but lead to the formation of amorphous calcium phosphate (i.e., with no crystal structure) instead. This layer produce some osseointegration yet the calcium phosphate layer will eventually dissolve and leave a gap between the bone and the dental implant, thus leading to osseointegration failure due to bacterial colonization. A new surface -recently obtained by thermochemical processes- produces, by crystallization, a layer of apatite with the same mineral content as human bone that is chemically bonded to the titanium surface. Osseointegration speed was tested by means of minipigs, showing bone formation after 3 to 4 weeks, with the security that a dental implant can be loaded. This surface can be an excellent candidate for immediate or early loading procedures. Key words:Dental implants, implants surfaces, osseointegration, biomimetics surfaces. PMID:25662555
Changes in soft tissues around immediate full-arch rehabilitations: a prospective study.
Covani, U; Ricci, M; D'Ambrosio, N; Quaranta, A; Barone, A
2013-08-01
Nowadays, aesthetic appearance is receiving more and more attention from clinicians and patients. Therefore, it is of paramount importance for the surgeon to maintain or to improve the quality and the stability of the soft tissue-implant interface. The scientific literature supports the idea that the immediate placement and provisionalization of endosseus implants and abutments can indeed offer additional clinical control over the peri-implant tissue architecture. On this basis, this prospective study aims to evaluate the changes in soft tissues around immediately loaded dental implants in full-arch rehabilitations, over a period of 3 months. Fifteen subjects were treated for immediate full-arch rehabilitations. Following implant placement, provisional rehabilitations made of bisphenol-A-glycidyldimethacrylate (BIS-GMA) and resin were placed. All records were made using a periodontal probe. The facial soft-tissue level was measured evaluating the distance between the soft-tissue margin and the incisal edge of the crown. Moreover, papilla levels were measured at the mesial and distal sites from a reference line connecting the occlusal edge of the crowns. The average value at the mesial site was -0.035 mm (±1, median 0 mm), while at the midfacial site, it was 0 mm (±0.76, median 0 mm) and at the distal site, -0.05 mm (±0.92, median 0 mm). The plaque score index showed a reduction during the follow-up period. Our data indicate that no differences at the midfacial point were detectable over the observation period. This is in agreement with several studies; it is plausible that these results are linked to a correct position of the implant in the alveolar socket. Moreover, comparing our results with what has been reported by other authors, it is surprising that while other studies highlight that papilla loss at the mesial and distal aspect is an expected consequence of immediate implant restorations, our data do not show any changes. The explanation of these results remains unclear. Further studies are needed to support our data and to clarify what mechanisms are involved in the maintenance of soft tissue. © 2012 John Wiley & Sons A/S.
Sun, Cong; Zhao, Jinxiu; Jianghao, Chen; Hong, Tao
2016-12-01
The objective of this study was to evaluate the implant stability and peri-implant tissue response in heavy smokers receiving dental implants due to partially edentulous posterior mandibles. Forty-five ITI Straumann dental implants were placed into the partially edentulous posterior mandibles of 16 heavy smokers and 16 nonsmokers. One implant in each patient was evaluated for implant stability after surgery and before loading, and for the modified plaque index (mPLI), modified sulcus bleeding index (mSBI), probing depth (PD), and marginal bone loss (MBL) after loading. Meanwhile, the osteogenic capability of jaw marrow samples collected from patients was evaluated via an in vitro mineralization test. For both groups, the implant stability quotient (ISQ) initially decreased from the initial ISQ achieved immediately after surgery and then increased starting from 2 weeks postsurgery. However, at 3, 4, 6, and 8 weeks postsurgery, the ISQ differed significantly between nonsmokers and heavy smokers. All implants achieved osseointegration without complications at least by the end of the 12th week postsurgery. At 6 or 12 months postloading, the MBL and PD were significantly higher in heavy smokers than in nonsmokers, whereas the mSBI and mPLI did not differ significantly between the 2 groups. The 1-year cumulative success rate of implants was 100% for both groups. Within the limitations of the present clinical study (such as small sample size and short study duration), which applied the loading at 3 months postoperation, heavy smoking did not affect the cumulative survival rate of dental implants placed at the posterior mandible in male patients, but heavy smoking did negatively affect bone healing around dental implants by decreasing the healing speed. These results implied that it might be of importance to select the right time point to apply the implant loading for heavy smokers. In addition, heavy smoking promoted the loss of marginal bone and the further development of dental pockets. Further clinical studies with larger patient populations are warranted to confirm our findings over a longer study duration.
French, David; Noroozi, Mehdi; Shariati, Batoul; Larjava, Hannu
2016-01-01
The aim of this retrospective study was to investigate whether self-reported allergy to penicillin may contribute to a higher rate of postsurgical infection and implant failure. This retrospective, non-interventional, open cohort study reports on implant survival and infection complications of 5,576 implants placed in private practice by one periodontist, and includes 4,132 implants that were followed for at least 1 year. Logistic regression was applied to examine the relationship between self-reported allergy to penicillin and implant survival, while controlling for potential confounders such as smoking, implant site, bone augmentation, loading protocol, immediate implantation, and bone level at baseline. The cumulative survival rate (CSR) was calculated according to the life table method and the Cox proportional hazard model was fitted to data. Out of 5,106 implants placed in patients taking penicillin it was found that 0.8% failed, while 2.1% failed of the 470 implants placed for patients with self-reported allergy to penicillin (P = .002). Odds of failure for implants placed in penicillin-allergic patients were 3.1 times higher than in non-allergic patients. For immediate implant placement, penicillin-allergic patients had a failure rate 10-times higher than the non-allergic cohort. Timing of implant failure occurring within 6 months following implantation was 80% in the penicillin-allergic group versus 54% in the non-allergic group. From the 48 implant sites showing postoperative infection: penicillin-allergic patients had an infection rate of 3.4% (n = 16/470) versus 0.6% in the non-allergic group (n = 32/5,106) (P < .05). Self-reported penicillin allergy was associated with a higher rate of infection, and primarily affected early implant failure.
El Hage, Marc; Abi Najm, Semaan; Bischof, Mvark; Nedir, Rabah; Carrel, Jean-Pierre; Bernard, Jean-Pierre
2012-06-01
The aims of this study were (1) to evaluate the vertical shrinkage percentage of nanocrystalline hydroxyapatite embedded in silica gel used for maxillary sinus floor elevation (SFE) and (2) to determine the survival rate of the implants 1 year after placement in the healed grafted sinuses. Eleven maxillary sinuses were augmented in eight patients with NanoBone. After a healing period averaging 14.42 months, 19 implants were placed and followed up with clinical and radiographic evaluation. Panoramic radiographs were taken immediately after SFE and at 12 months after grafting. Measurements of changes in height were made by a computerized measuring technique using an image editing software. The mean graft height shrinkage percentage at 12 months after surgery was 8.84% (±5.32). One implant was lost before loading. All the 18 remaining osseointegrated implants received the prosthetic rehabilitation and were controlled after 3 months of functional loading. The implant survival rate at the 1-year interval was 94.74%. A 100% NanoBone alloplastic graft used in lateral SFE procedures presented limited height shrinkage. Implants placed in these grafted sinuses showed survival rates similar to those found in published data. These results should be interpreted cautiously considering the study's reduced sample size.
Miniscrew implants as temporary anchorage devices in orthodontics: a comprehensive review.
Jasoria, Gaurav; Shamim, Wamiq; Rathore, Saurabh; Kalra, Amit; Manchanda, Mona; Jaggi, Nitin
2013-09-01
In recent times, the use of miniscrew implants to obtain absolute anchorage has gained momentum in clinical orthodontics as rigid anchorage modality. Miniscrew implants offers many advantages when used as temporary anchorage devices like, easy placement and removal, immediate loading, can be used in a variety of locations, provide absolute anchorage, economic and requires less patient cooperation. This makes them as a necessary treatment option in cases with critical anchorage that would have otherwise resulted in anchorage loss if treated with conventional means of anchorage. The aim of this comprehensive review is to highlight the gradual evolution, clinical use, advantages and disadvantages of the miniscrew implants when used to obtain a temporary but absolute skeletal anchorage for orthodontic applications.
10-year prospective cohort follow-up of immediately restored XiVE implants.
Degidi, Marco; Nardi, Diego; Piattelli, Adriano
2016-06-01
The aim of this prospective cohort study was to assess the ten-year performance of the condensing thread, self-tapping apex and internal hexagonal connection XiVE implant supporting partial fixed prostheses placed with an immediate restoration approach. All patients received a fixed two- to four-unit partial provisional restoration supported by immediately loaded implants. The final gold alloy/ceramic restorations were cemented approximately 28 weeks after implant insertion. Marginal bone level, pocket probing depth and percentage of bleeding on probing, biological or technical complications and any other adverse events were measured annually up to ten years after surgery. The overall success and survival rates at implant level were evaluated following the International Congress of Oral Implantologists (ICOI) Pisa Consensus Conference criteria. Implant placement in post-extractive or healed sites, smoking and a history of periodontal treatment were evaluated to assess whether they had an influence on bone resorption or on implant survival. Of 114 patients, for a total of 284 implants, fulfilled all the inclusion criteria and were enrolled in the study. 78 (27.5%) implants placed in 30 (26.3%) patients were lost to follow-up. Eight of 284 (2.8%) implants failed in 8 of 114 (7.0%) patients: one (12.5% of losses) due to failure to achieve osseointegration and seven (87.5% of losses) due to peri-implantitis. No cluster implant failures were assessed. The failure of the implant caused the failure of the prosthesis due to the strategic position of the implant in four patients. At the final ten-year follow-up, 121 (61.4%) implants exhibited a "full success" status with an optimal health condition, 21 (10.9%) implants scored a "satisfactory survival" condition, while 49 (25.49%) of the implants were classified as "compromised survival" status (Misch et al. 2008). Smoking was found to be statistically associated with "implant failure" (P = 0.010), while no association was found for patients treated for periodontal disease (P = 0.679) and post-extractive surgical sites (P = 0.664). Statistically significant more marginal bone loss was found in patients treated for periodontal disease (P < 0.0001). An increased bone loss was also observed in smokers, but the difference with the non-smokers was not statistically significant (P = 0.06). The XiVE implants can be successfully used to support immediate prosthesis. Patients with a history of periodontitis show increased bone loss and risk to develop peri-implant disease. Smoking seems to jeopardize the long-term implant survival. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Bechara, Soheil; Lukosiunas, Algirdas; Kubilius, Ricardas
2017-01-01
Purpose. To evaluate implant survival, peri-implant bone loss, and complications affecting fixed full-arch (FFA) restorations supported by implants with a knife-edge thread design and nanostructured, calcium-incorporated surface. Methods. Between January 2013 and December 2015, all patients referred for implant-supported FFA restorations were considered for enrollment in this study. All patients received implants with a knife-edge thread design and nanostructured calcium-incorporated surface (Anyridge®, Megagen, South Korea) were restored with FFA restorations and enrolled in a recall program. The final outcomes were implant survival, peri-implant bone loss, biologic/prosthetic complications, and “complication-free” survival of restorations. Results. Twenty-four patients were selected. Overall, 215 implants were inserted (130 maxilla, 85 mandible), 144 in extraction sockets and 71 in healed ridges. Thirty-six FFAs were delivered (21 maxilla, 15 mandible): 27 were immediately loaded and 9 were conventionally loaded. The follow-up ranged from 1 to 3 years. Two fixtures failed, yielding an implant survival rate of 95.9% (patient-based). A few complications were registered, for a “complication-free” survival of restorations of 88.9%. Conclusions. FFA restorations supported by implants with a knife-edge thread design and nanostructured, calcium-incorporated surface are successful in the short term, with high survival and low complication rates; long-term studies are needed to confirm these outcomes. PMID:28246595
Slotte, Christer; Lennerås, Maria; Göthberg, Catharina; Suska, Felicia; Zoric, Neven; Thomsen, Peter; Nannmark, Ulf
2012-10-01
Early detection of healing complications after placement of dental implants is a pressing but elusive goal. This paper proposes a non-invasive diagnostic tool for monitoring healing- and peri-implant disease specific genes, complementary to clinical evaluations. Eighteen partially edentulous patients were recruited to this pilot study. Three Brånemark TiUnite® implants/patient (Nobel Biocare) were placed in a one-stage procedure. Abutments with smooth or rough (TiUnite®) surface were placed. The test group (n = 9) received fixed bridges (immediate loading), whereas the control group (n = 9) implants were loaded 3 months after surgery. In addition to clinical measurements, crevicular fluid was collected using paper strips at the implant abutments 2, 14, 28, and 90 days postoperative. mRNA was extracted, purified, and converted to cDNA. Quantitative PCR assays for IL-1β, TNF-α, Osteocalcin (OC), Alkaline Phosphatase (ALP), Cathepsin K, Tartrate Resistant Acid Phosphatase, and 18S ribosomal RNA were designed and validated. Relative gene expression levels were calculated. One implant was lost in the control group and three in the test group. In one test patient, one implant showed lowered stability after 2 to 4 weeks and was unloaded. Later implant stability improved which allowed for loading after 3 to 4 months. TNF-α and ALP most commonly showed correlation with clinical parameters followed by IL-1β and OC. The strongest correlation was found for TNF-α with clinical complications at 2 and 14 days (p = .01/r = -048, and p = .0004/r = -0.56, respectively; test and control groups together). In some cases, gene expression predicted clinical complications (TNF-α, ALP, CK). This study is based on samples from few individuals; still, some genes showed correlation with clinical findings. Further studies are needed to refine and optimize the sampling process, to find the appropriate panel, and to validate gene expression for monitoring implant healing. © 2010 Wiley Periodicals, Inc.
Mainetti, Tomaso; Lang, Niklaus P; Bengazi, Franco; Favero, Vittorio; Soto Cantero, Luis; Botticelli, Daniele
2016-01-01
To compare the sequential healing at implants installed in a healed alveolar bony ridge or immediately after tooth extraction without functional load. In the mandible of 12 dogs, the mesial roots of the first molars were endodontically treated, the tooth hemisected, and the distal roots extracted. After 3 months, the mesial roots of the fourth premolars were endodontically treated, the tooth hemisected, and the distal roots extracted in one side of the mandible. Implants were placed immediately into extraction sockets (IPIES) of the fourth premolar and in the healed sites in the molar regions. Healing abutments were placed, and the flaps were sutured to allow a non-submerged healing. The time of surgery and of sacrifices were planned in such a way to obtain biopsies representing the healing after 1 and 2 weeks and 1 and 3 months, respectively. Ground sections were prepared for histological evaluation of tissues components on the implant surface and the coronal termination level of osseointegration (M-B). New bone apposition on the implant surface was slightly higher at the healed compared to the IPIES sites, being 7.4% and 4.1% after 1 week, and 67.3% and 65.3% after 3 months, respectively. Old bone was progressively resorbed, from 27.0% and 21.9% after 1 week, to 2.5% and 2.0% after 3 months, at healed and IPIES sites, respectively. M-B was 1.4 mm and 2.6 mm after 1 week, 1.2 mm and 1.2 mm after 3 months, at healed and IPIES sites, respectively. Similar patterns of sequential osseointegration were found at implants installed in healed alveolar bone or in alveolar sockets immediately after tooth extraction. The coronal termination level of osseointegration, that was different after 1 week, was found similar at the 3-month observation. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Clinical evaluation of the stability of implants placed at different supracrestal levels.
Gultekin, B Alper; Sirali, Ali; Gultekin, Pinar; Ersanli, Selim
2016-01-01
The aim of this study was to evaluate the stability during healing and before loading of implants placed at two different supracrestal levels according to their collar texture. This retrospective study included patients who received posterior implants with the same macro design. Implants with a machined collar were placed 0.3 mm above the crestal bone (M group), while those with a laser-microtextured collar were placed 1 mm above the crestal bone (L group). All implants healed in a single stage with healing abutments. Implant stability quotient (ISQ) values were determined using resonance frequency analysis immediately after implant placement during surgery and after 1, 4, 8, and 12 weeks after surgery. Other evaluated factors for stability included the implant diameter and length and the site of placement (maxilla or mandible). In total, 103 implants (47 L, 56 M) were evaluated. The median ISQ values at baseline and 1 week after placement were significantly higher for the M group than for the L group (p=0.006 and p=0.031, respectively). There were no differences at the subsequent observation points. The ISQ value was higher for wide-diameter than regular diameter (p=0.001) and mandibular implants than maxillary implants (p=0.001 at 0-8. weeks; p=0.012 at 12 weeks) at all observation points. When diameter data were neglected, the implant length did not influence the ISQ value at all observation points. Our results suggest that submerging implant more inside bone may only influence primary stability. Moreover, the implant diameter and site of placement influence primary and secondary stability before loading, whereas the implant length does not when its diameter is not accounted for.
Oliveira, Leandro Benetti de; Gabrielli, Marisa Aparecida Cabrini; Gabrielli, Mario Francisco Real; Pereira-Filho, Valfrido Antonio Pereira
2015-12-01
The objective of this article is to present options of rehabilitation with dental implants in two cases of severely atrophic mandibles (<10 mm) after rigid internal fixation of fractures. Two patients who sustained fractures in severely atrophic mandibles with less than 10 mm of bone height were treated by open reduction and internal fixation through a transcervical access. Internal fixation was obtained with 2.4-mm locking reconstruction plates. The first patient presented satisfactory bone height at the area between the mental foramens and after 2 years, received flapless guided implants in the anterior mandible and an immediate protocol prosthesis. The second patient received a tent pole iliac crest autogenous graft after 2 years of fracture treatment and immediate implants. After 5 months, a protocol prosthesis was installed in the second patient. In both cases, the internal fixation followed AO principles for load-bearing osteosynthesis. Both prosthetic devices were Branemark protocol prosthesis. The mandibular reconstruction plates were not removed. Both patients are rehabilitated without complications and satisfied with esthetic and functional results. With the current techniques of internal fixation, grafting, and guided implants, the treatment of atrophic mandible fractures can achieve very good results, which were previously not possible.
Soft-Tissue Grafting Techniques Associated With Immediate Implant Placement.
Bishara, Mark; Kurtzman, Gregori M; Khan, Waji; Choukroun, Joseph; Miron, Richard J
2018-02-01
Immediate implant placement often presents challenges in terms of predictably obtaining soft-tissue coverage over the implant site. While delayed implant placement offers the ability for soft tissues to grow and invade the extraction socket making their attachment around implants more predictable, immediate implant placement poses a significant risk of bacterial invasion towards the implant surface as a result of insignificant soft-tissue volume. Soft-tissue grafting techniques have often been proposed for use during immediate implant placement to augment soft-tissue deficiencies, including the use of either palatal connective tissue grafts (CTGs) or collagen-derived scaffolds. However, both of these approaches have significant drawbacks in that CTGs are harvested with high patient morbidity and collagen scaffolds remain avascular and acelluar posing a risk of infection/implant contamination. More recently, platelet-rich fibrin (PRF) has been proposed as an economical and biological means to speed soft-tissue wound healing. In combination with immediate implant placement, PRF offers an easily procurable low-cost regenerative modality that offers an efficient way to improve soft-tissue attachment around implants. Furthermore, the supra-physiological concentration of defense-fighting leukocytes in PRF, combined with a dense fibrin meshwork, is known to prevent early bacterial contamination of implant surfaces, and the biological concentrations of autologous growth factors in PRF is known to increase tissue regeneration. This article discusses soft-tissue grafting techniques associated with immediate implant placement, presents several cases demonstrating the use of PRF in routine immediate implant placement, and further discusses the biological and economic advantages of PRF for the management of soft-tissue grafting during immediate implant placement.
Immediate placement of endosseous implants into the extraction sockets.
Ebenezer, Vijay; Balakrishnan, K; Asir, R Vigil Dev; Sragunar, Banu
2015-04-01
Implant by definition "means any object or material, such as an alloplastic substance or other tissue, which is partial or completely inserted into the body for therapeutic, diagnostic, prosthetic, or experimental purpose." The placement of a dental implant in an extraction socket at the time of extraction or explantation is known as immediate implant placement whereas delayed placement of implant signifies the implant placement in edentulous areas where healing has completed with new bone formation after the loss of tooth/teeth. Recent idea goes by "why late when it can be done immediately." There are several advantages of immediate placement of implants, and lots of studies have been done. In this article, the advantages and disadvantages of immediate versus delayed placement of implants have been reviewed.
Immediate Implants: Clinical Guidelines for Esthetic Outcomes
Javaid, Mohammad A.; Khurshid, Zohaib; Zafar, Muhammad S.; Najeeb, Shariq
2016-01-01
Research has shown that tooth loss results in morphological changes in alveolar ridge that may influence the subsequent implant placement. Immediate implant placement was introduced as a possible means to limit bone resorption and reduce the number of surgical procedures following tooth extraction. Histological and clinical evidence from human clinical studies showing efficacy of immediate implants has come to light over the last decade or so. However, immediate implant placement is a challenging surgical procedure and requires proper case selection and surgical technique. Furthermore, there appears to be a lack of clinical guidelines for immediate implant placement case selection. Therefore, the aim of this mini-review is to analyze critical evidence from human studies in order to establish clinical guidelines which may help clinicians in case selection when considering immediate implant placement protocol. PMID:29563463
Ben Amara, Heithem; Lee, Jung-Won; Kim, Jung-Ju; Kang, Yun-Mi; Kang, Eun-Jung; Koo, Ki-Tae
Evidence on the outcomes of functional loading placed in recombinant human bone morphogenetic protein 2 (rhBMP-2)/acellular collagen sponge (ACS)-induced bone is lacking. The aim of this study was to verify whether guided bone regeneration (GBR) with rhBMP-2/ACS enhances regeneration of missing bone and osseointegration of dental implants subject to functional loading. Two bilateral standardized large saddle-type defects (≈10 × 10 × 6 mm) were surgically created in each mandible of seven beagle dogs 2 months after tooth extraction. Defects were immediately reconstructed randomly using rhBMP-2 (O-BMP or InFuse) soaked in ACS, deproteinized bovine bone mineral (DBBM) granules, or ACS alone as surgical control and subsequently covered with collagen membrane. Screw-type sand-blasted, acid-etched dental implants were placed 3 months later into the reconstructed defects and into adjacent bone. Osseointegration was allowed to progress for 3 months before functional loading of 3 months until sacrifice. Significantly more bone fill was radiographically observed for GBR with rhBMP-2/ACS (O-BMP: 92.5%, InFuse: 79%) in comparison to the DBBM (52%) and ACS alone groups (56.6%). Osseointegration was achieved and maintained in all experimental defects challenged by prostheses-driven functional load. The bone density ranged from 37.49% in the ACS group to 64.9% in the rhBMP-2/ACS (InFuse) group with no significance. The highest mean percentage of BIC was found in rhBMP-2/ACS (InFuse: 52.98%) with no statistical difference. Crestal bone resorption was observed around implants placed in reconstructed areas without any significant difference. GBR with rhBMP-2/ACS provided the greatest bone fill among the three treatment procedures. GBR with rhBMP-2/ACS showed efficacy for placement, osseointegration, and functional loading of titanium implants in alveolar ridge defects.
Characterization of retrieved orthodontic miniscrew implants.
Eliades, Theodore; Zinelis, Spiros; Papadopoulos, Moschos A; Eliades, George
2009-01-01
The purposes of this study were to characterize the morphologic, structural, and compositional alterations and to assess any hardness changes in used orthodontic miniscrew implants. Eleven miniscrew implants (Aarhus Anchorage System, Medicon eG, Tuttlingen, Germany) placed in 5 patients were retrieved after successful service of 3.5 to 17.5 months; none showed signs of mobility or failure. These implants, and brand-, type-, and size-matched specimens as controls, were subjected to multi-technique characterization. Optical microscopy indicated loss of gloss with variable discoloration. Scanning electron microscopy and x-ray microanalysis showed morphologic alteration of the miniscrew implant surfaces with integuments formed on the surface. The materials precipitated on the surfaces were sodium, potassium, chlorine, iron, calcium, and phosphorus from the contact of the implant with biologic fluids such as blood and exudates, forming sodium chloride, potassium chloride, and calcium-phosphorus precipitates. The composition of the implant was similar to that of a titanium alloy. X-ray microtomography analysis showed no bulk structure alterations. Vickers microhardness testing showed no increased bulk or surface hardness of the retrieved specimens compared with the controls, excluding the possibility of strain-hardening phenomena as a result of self-tapping and self-drilling placement and related loading conditions. Used titanium-alloy miniscrew implants have morphologic and surface structural alterations including adsorption of an integument that is calcified as a result of contact of the implants with biologic fluids. Randomly organized osseointegration islets on these smooth titanium-alloy miniscrew surfaces might be enhanced by the extended period of retention in alveolar bone in spite of the smooth surface and immediate loading pattern of these implants.
[Esthetic analysis on immediate single-tooth implant restoration in anterior maxilla].
Li, Shao-wei; Wang, Guo-shi; Sha, Yan-zhi
2015-10-01
To evaluate the esthetic outcomes of immediate single-tooth implant restoration in anterior maxilla with the pink esthetic score (PES). Nine patients were treated with 9 Straumann implants by immediate single-tooth implant restoration in anterior maxilla. Assessment of PES after crown placement at 1 week (baseline) and 6 months after implantation was conducted. Statistical analysis was performed using SPSS 16.0 software package. Nine implants achieved a retention rate of 100%. PES for single-tooth implant was 10.33 ± 1.50 at 1 week and 11.44 ± 0.88 at 6 months after crown placement. The difference was significant(P=0.021). This study indicates that immediate single-tooth implant restoration in anterior maxilla is predictable. Immediate single-tooth implantation can result in good clinical esthetic results in most patients with single-tooth missing in anterior maxilla.
Immediate placement of endosseous implants into the extraction sockets
Ebenezer, Vijay; Balakrishnan, K.; Asir, R. Vigil Dev; Sragunar, Banu
2015-01-01
Implant by definition “means any object or material, such as an alloplastic substance or other tissue, which is partial or completely inserted into the body for therapeutic, diagnostic, prosthetic, or experimental purpose.” The placement of a dental implant in an extraction socket at the time of extraction or explantation is known as immediate implant placement whereas delayed placement of implant signifies the implant placement in edentulous areas where healing has completed with new bone formation after the loss of tooth/teeth. Recent idea goes by “why late when it can be done immediately.” There are several advantages of immediate placement of implants, and lots of studies have been done. In this article, the advantages and disadvantages of immediate versus delayed placement of implants have been reviewed. PMID:26015721
Effects of a cochlear implant simulation on immediate memory in normal-hearing adults
Burkholder, Rose A.; Pisoni, David B.; Svirsky, Mario A.
2012-01-01
This study assessed the effects of stimulus misidentification and memory processing errors on immediate memory span in 25 normal-hearing adults exposed to degraded auditory input simulating signals provided by a cochlear implant. The identification accuracy of degraded digits in isolation was measured before digit span testing. Forward and backward digit spans were shorter when digits were degraded than when they were normal. Participants’ normal digit spans and their accuracy in identifying isolated digits were used to predict digit spans in the degraded speech condition. The observed digit spans in degraded conditions did not differ significantly from predicted digit spans. This suggests that the decrease in memory span is related primarily to misidentification of digits rather than memory processing errors related to cognitive load. These findings provide complementary information to earlier research on auditory memory span of listeners exposed to degraded speech either experimentally or as a consequence of a hearing-impairment. PMID:16317807
A 5-year prospective study on single immediate implants in the aesthetic zone.
Cosyn, Jan; Eghbali, Aryan; Hermans, Alexander; Vervaeke, Stijn; De Bruyn, Hugo; Cleymaet, Roberto
2016-08-01
There is a paucity of long-term data on soft tissue aesthetics of single immediate implants. The objective of this study was to evaluate the 5-year clinical and aesthetic outcome of this treatment concept. Twenty-two periodontally healthy patients (12 men, 10 women; mean age 50) with low risk for aesthetic complications (thick gingival biotype, intact buccal bone wall, both neighbouring teeth present) were consecutively treated with a single immediate implant in the aesthetic zone (15-25). Flapless surgery was performed and the gap between the implant and buccal bone wall was systematically filled with bovine bone particles. Implants were immediately non-functionally loaded with a screw-retained provisional crown. Cases demonstrating major alveolar process changes and/or advanced mid-facial recession (>1 mm) at 3 months were additionally treated with a connective tissue graft (CTG). Permanent crowns were installed at 6 months. The clinical and aesthetic results at 5 years were compared to those obtained at 1 year. Seventeen patients attended the 5-year re-assessment, of whom five had been treated with a CTG for early aesthetic complications. There was one early implant failure and one complication after 1 year (porcelain chipping). Mean marginal bone loss was 0.12 mm at 1 year and 0.19 mm at 5 years (p = 0.595) with the moment of implant installation as baseline. Papilla height increased between 1 and 5 years (p ≤ 0.007), whereas mid-facial contour (p = 0.005) and alveolar process deficiency (p = 0.008) deteriorated. Mean mid-facial recession was on average 0.28 mm (SD 0.48) at 1 year and 0.53 mm (SD 0.53) at 5 years (p = 0.072) with the preoperative status as baseline. Three implants demonstrated advanced mid-facial recession (>1 mm) at 5 years. All three were in a central incisor position and none had been treated with a CTG. Thus, 8/17 implants showed aesthetic complications (five early and three late aesthetic complications). Implants in a lateral incisor position showed stable soft tissue levels. The pink aesthetic score was on average 12.15 at 1 year and 11.18 at 5 years (p = 0.030). Single immediate implants showed high implant survival and limited marginal bone loss in the long term. However, mid-facial recession, mid-facial contour and alveolar process deficiency deteriorated after 1 year. With an aesthetic complication rate of 8/17 in well-selected patients who had been treated by experienced clinicians, type I placement may not be recommended for daily practice. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Waki, Tomonori; Kan, Joseph Y K
2016-01-01
Immediate implant placement and provisionalization in the esthetic zone have been documented with success. The benefit of immediate implant placement and provisionalization is the preservation of papillary mucosa. However, in cases with osseous defects presenting on the facial bony plate, immediate implant placement procedures have resulted in facial gingival recession. Subepithelial connective tissue grafts for immediate implant placement and provisionalization procedures have been reported with a good esthetic outcome. Biotype conversion around implants with subepithelial connective tissue grafts have been advocated, and the resulting tissues appear to be more resistant to recession. The dimensions of peri-implant mucosa in a thick biotype were significantly greater than in a thin biotype. Connective tissue graft with coronally positioned flap procedures on natural teeth has also been documented with success. This article describes a technique combining immediate implant placement, provisionalization, guided bone regeneration (GBR), connective tissue graft, and a coronally positioned flap in order to achieve more stable peri-implant tissue in facial osseous defect situations.
Sendi, Pedram; Bertschinger, Nadine; Brand, Christina; Marinello, Carlo P; Bucher, Heiner C; Bornstein, Michael M
2017-01-01
Two interforaminal dental implants in is a common treatment option for denture retention in edentulous patients. Economic methods to assess the patient's quality of life include the willingness to pay (WTP) for implant treatment and willingness to accept (WTA) to forgo implant treatment. The purpose of this study was to assess the monetary value of implant retained complete dentures using WTP and WTA. We included a convenience sample of 16 patients from a previously published cohort study on the survival of immediately loaded implants in edentulous patients to assess WTP and WTA for this treatment option. The average maximum WTP for implant treatment was 4606 (95% CI: 2991-6222) Swiss Francs. Out of the 16 patients, only 5 were willing to trade their implants for money, with a mean WTA of CHF 33'500 (range: 3000-100'000).All patients would agree to undergo the implant surgery procedure again. The results of the present study show that most patients are not willing to trade the increase in quality of life after implant surgery against money, suggesting that WTA exceeds by large WTP for the same health condition.
Cavalli, Nicolò; Barbaro, Bruno; Spasari, Davide; Azzola, Francesco; Ciatti, Alberto; Francetti, Luca
2012-01-01
Purpose. The aims of this study were to assess the treatment outcome of immediately loaded full-arch fixed bridges anchored to both tilted and axially placed implants in the edentulous maxilla and to evaluate the incidence of biological and prosthetic complications. Materials and Methods. Thirty-four patients (18 women and 16 men) were included in the study. Each patient received a maxillary full-arch fixed bridge supported by two axial implants and two distal tilted implants. A total of 136 implants were inserted. Loading was applied within 48 hours of surgery and definitive restorations were placed 4 to 6 months later. Patients were scheduled for followup at 6, 12, 18, and 24 months and annually up to 5 years. At each followup plaque level and bleeding scores were assessed and every complication was recorded. Results. The overall follow-up range was 12 to 73 months (mean 38.8 months). No implant failures were recorded to date, leading to a cumulative implant survival rate of 100%. Biological complications were recorded such as alveolar mucositis (11.8% patients), peri-implantitis (5.9% patients), and temporomandibular joint pain (5.9% patients). The most common prosthetic complications were the fracture or detachment of one or multiple acrylic teeth in both the temporary (20.6% patients) and definitive (17.7% patients) prosthesis and the minor acrylic fractures in the temporary (14.7% patients) and definitive (2.9% patients) prosthesis. Hygienic complications occurred in 38.2% patients. No patients' dissatisfactions were recorded. Conclusions. The high cumulative implant survival rate indicates that this technique could be considered a viable treatment option. An effective recall program is important to early intercept and correct prosthetic and biologic complications in order to avoid implant and prosthetic failures. PMID:23133453
Kumar, Vinay V; Jacob, P C; Kuriakose, Moni A
2016-12-01
In patients with reconstructed mandibles using free fibula flaps, management of soft tissues around implants supporting dental rehabilitation, is often a clinical problem. The aim of this paper is to describe a new technique, namely "Sub-periosteal dissection and denture-guided epithelial regeneration (SD-DGER)", as a method of peri-implant soft tissue management in these patients. The technique consists of performing a subperiosteal dissection with creation of buccal and lingual flaps. These flaps form the buccal and lingual vestibule. Implants are placed and an interim denture is immediately loaded onto the implants to guide the regenerated epithelium. A keratinized mucosal layer is formed on the bare fibula bone in six months time. This technique was successful in producing fixed keratinized epithelial tissue around implants in patients with mandibles reconstructed using the free fibula flap in patients who did not undergo radiotherapy. The sub-periosteal dissection with denture guided epithelial regeneration is a predictable form of peri-implant soft tissue management in selected patients with reconstructed jaws.
Teaching mandibular implant-Supported overdentures in dental schools in North America - a survey.
Ben-Gal, G; Ziv, Y; Weiss, E I; Zabrovsky, A
2017-05-01
Mandibular two-implant overdentures are considered the minimum standard of care for edentulous patients and provide an excellent performance, as well as satisfaction to the patients. Dental schools are required to promote the teaching of current treatment options in order to enable students to master state-of-the-art procedures. The purpose of this study was to examine how the theoretical and practical aspects of mandibular two-implant overdentures are taught in dental schools in North America. Data were collected via an online questionnaire that included questions regarding the theoretical and clinical courses, surgical procedure and imaging method. Of 75 schools, 36 responded to the survey. Almost all the schools teach the subject theoretically, but it is not mandatory for students to perform in most of the schools. Only a minority (23%) of the mandibular dentures made by students are implant-supported. Almost all of the schools (94%) use two implants to support overdentures, and Locator abutment is used almost exclusively. The prevalent imaging for the surgical procedure is CT scans, although 30% of the schools use panoramic radiograph. None of the schools loads the implants immediately after surgery. Some clear trends are apparent in the current survey: the use of two implants, no use of bar connectors and delayed loading of the implants. It is likely that graduates will not have sufficient clinical skills and will need continuing education to be familiar with the required procedures, both surgical and prosthetic. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Fracture of Reduced-Diameter Zirconia Dental Implants Following Repeated Insertion.
Karl, Matthias; Scherg, Stefan; Grobecker-Karl, Tanja
Achievement of high insertion torque values indicating good primary stability is a goal during dental implant placement. The objective of this study was to evaluate whether or not two-piece implants made from zirconia ceramic may be damaged as a result of torque application. A total of 10 two-piece zirconia implants were repeatedly inserted into polyurethane foam material with increasing density and decreasing osteotomy size. The insertion torque applied was measured, and implants were checked for fractures by applying the fluorescent penetrant method. Weibull probability of failure was calculated based on the recorded insertion torque values. Catastrophic failures could be seen in five of the implants from two different batches at insertion torques ranging from 46.0 to 70.5 Ncm, while the remaining implants (all belonging to one batch) survived. Weibull probability of failure seems to be low at the manufacturer-recommended maximum insertion torque of 35 Ncm. Chipping fractures at the thread tips as well as tool marks were the only otherwise observed irregularities. While high insertion torques may be desirable for immediate loading protocols, zirconia implants may fracture when manufacturer-recommended insertion torques are exceeded. Evaluating bone quality prior to implant insertion may be useful.
Survival of Implants in Immediate Extraction Sockets of Anterior Teeth: Early Clinical Results.
Sabir, Mohammad; Alam, Mohammad Nazish
2015-06-01
The aims and objectives of this study were placement of implants in freshly extracted sockets of anterior teeth and to evaluate the implant stability, peri-implant radiolucency and gingival inflammation around implant over a short period of 30 months. A total of 12 patients (8 male and 4 female), ranging in the age from 20 to 50 years, from March 2007 to June 2007, were evaluated for immediate implant placement into 22 fresh extraction sockets. Only maxillary and mandibular anterior teeth/roots (central incisors, lateral incisors and canines) were considered for replacement with implants. One piece implant with integrated abutment and integrated surface, non-submerged, threaded and tapered at apical 5 mm, sand-blasted and acid etched surfaced implants (HI-TEC TRX-OP Implants of Life Care Company) were used. The mobility was not present in any of the implants at all the follow up visits. There were 2 implants at 6 month, 1 implant at 12 month, 1 implant at 18 month visits, showing peri-implant radiolucency at some sites at bone to implant contact site. Severe gingival inflammation was not observed in any of the implant site. At every follow-up visit, every implant met the criteria of success and none was found to be failed over a 30 months duration i.e. 100% success rate was achieved by implants in immediate extraction socket. The success rate of implant survival in this study was found 100%. These implants have fulfilled all the criteria of implant success and based on the defined criteria, the success rate of implants placed in immediate extraction sockets of anterior teeth compared favorably with the conventional implants. The early results of the present study showed that high survival rates with the implants in immediate extraction sockets can be achieved.
Alvarez-Arenal, Angel; Gonzalez-Gonzalez, Ignacio; deLlanos-Lanchares, Hector; Brizuela-Velasco, Aritza; Dds, Elena Martin-Fernandez; Ellacuria-Echebarria, Joseba
2017-12-01
The aim of this study was to evaluate and compare the bone stress around implants in mandibular 2-implant overdentures depending on the implant location and different loading conditions. Four 3-dimensional finite element models simulating a mandibular 2-implant overdenture and a Locator attachment system were designed. The implants were located at the lateral incisor, canine, second premolar, and crossed-implant levels. A 150 N unilateral and bilateral vertical load of different location was applied, as was 40 N when combined with midline load. Data for von Mises stress were produced numerically, color coded, and compared between the models for peri-implant bone and loading conditions. With unilateral loading, in all 4 models much higher peri-implant bone stress values were recorded on the load side compared with the no-load side, while with bilateral occlusal loading, the stress distribution was similar on both sides. In all models, the posterior unilateral load showed the highest stress, which decreased as the load was applied more mesially. In general, the best biomechanical environment in the peri-implant bone was found in the model with implants at premolar level. In the crossed-implant model, the load side greatly altered the biomechanical environment. Overall, the overdenture with implants at second premolar level should be the chosen design, regardless of where the load is applied. The occlusal loading application site influences the bone stress around the implant. Bilateral occlusal loading distributes the peri-implant bone stress symmetrically, while unilateral loading increases it greatly on the load side, no matter where the implants are located.
Bacchiocchi, Danilo
2017-01-01
Purpose To present a new intraoral welding technique, which can be used to manufacture screw-retained, mandibular fixed full-arch prostheses. Methods Over a 4-year period, all patients with complete mandibular edentulism or irreparably compromised mandibular dentition, who will restore the masticatory function with a fixed mandibular prosthesis, were considered for inclusion in this study. The “Ball Welding Bar” (BWB) technique is characterised by smooth prosthetic cylinders, interconnected by means of titanium bars which are adjustable in terms of distance from ball terminals and are inserted in the rotating rings of the cylinders. All the components are welded and self-posing. Results Forty-two patients (18 males; 24 females; mean age 64.2 ± 6.7 years) were enrolled and 210 fixtures were inserted to support 42 mandibular screw-retained, fixed full-arch prostheses. After two years of loading, 2 fixtures were lost, for an implant survival rate of 97.7%. Five implants suffered from peri-implant mucositis and 3 implants for peri-implantitis. Three of the prostheses (3/42) required repair for fracture (7.1%): the prosthetic success was 92.9%. Conclusions The BWB technique seems to represent a reliable technique for the fabrication of screw-retained mandibular fixed full-arch prostheses. This study was registered in the ISRCTN register with number ISRCTN71229338. PMID:28835752
Noelken, Robert; Neffe, Bettina Anna; Kunkel, Martin; Wagner, Wilfried
2014-02-01
Placement of implants into extraction sockets targets the maintenance of peri-implant hard and soft tissue structures and the support of a natural and esthetic contour. The main advantages of immediate implant insertion in comparison with delayed implant placement protocols are as follows: a reduced treatment time, less number of sessions, and, thus, the less invasive procedure. This study examines the clinical performance (survival rate, marginal bone levels and Pink Esthetic Score [PES]) of OsseoSpeed implants placed into extraction sockets with immediate provisionalization in the anterior maxilla after a follow-up of at least 12 months. Twenty patients received a total number of 37 OsseoSpeed implants which were immediately inserted into extraction sockets with or without facial bone deficiencies of various dimensions. A flapless procedure was applied, and the implants were immediately provisionalized with temporary crowns without occlusal contacts. Facial gaps between implant surface and facial bone or the previous contour of the alveolar process were grafted with autogenous bone chips. Implants in diameters 3.5, 4.0, 4.5, and 5.0 with lengths of 11-17 mm were used in the study. During the course of the study, interproximal marginal bone levels, the thickness of the facial bony wall, implant success rate according to the criteria established by Buser, and the PES were assessed per implant. One patient with three implants did not continue the study after prosthesis delivery, the remaining 34 implants were still in function at the final follow-up (survival rate: 100%). The mean follow-up period was 27 months (range, 12-40 months). Marginal bone height at the level of the implant shoulder averaged -0.1 ± 0.55 mm (range, -1.25 to 1.47 mm) at the final follow-up. The mean PES ratings were 11.3 ± 1.8 (range, 6-14) at the final follow-up. In 78% of the patients, the PES was preserved or even improved. Success rates, marginal bone levels, and esthetic results suggest proof of principle for the preservation of marginal bone height at immediately placed and provisionalized OsseoSpeed implants after a follow-up of at least 12 months. Even implant sites with facial bony deficiencies can be successfully treated with a favorable esthetic outcome using the immediate implant insertion, immediate reconstruction, and immediate provisionalization technique. © 2013 John Wiley & Sons A/S.
Aw, Moom Sinn; Losic, Dusan
2013-02-25
A non-invasive and external stimulus-driven local drug delivery system (DDS) based on titania nanotube (TNT) arrays loaded with drug encapsulated polymeric micelles as drug carriers and ultrasound generator is described. Ultrasound waves (USW) generated by a pulsating sonication probe (Sonotrode) in phosphate buffered saline (PBS) at pH 7.2 as the medium for transmitting pressure waves, were used to release drug-loaded nano-carriers from the TNT arrays. It was demonstrated that a very rapid release in pulsatile mode can be achieved, controlled by several parameters on the ultrasonic generator. This includes pulse length, time, amplitude and power intensity. By optimization of these parameters, an immediate drug-micelles release of 100% that spans a desirable time of 5-50 min was achieved. It was shown that stimulated release can be generated and reproduced at any time throughout the TNT-Ti implant life, suggesting considerable potential of this approach as a feasible and tunable ultrasound-mediated drug delivery system in situ via drug-releasing implants. It is expected that this concept can be translated from an in vitro to in vivo regime for therapeutic applications using drug-releasing implants in orthopedic and coronary stents. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.
Microbiota in experimental periodontitis and peri-implantitis in dogs.
Charalampakis, Georgios; Abrahamsson, Ingemar; Carcuac, Olivier; Dahlén, Gunnar; Berglundh, Tord
2014-09-01
To analyze the microbial profile around teeth and implants following ligature removal in experimental periodontitis and peri-implantitis in dogs. Four implants with similar geometry and with two different surface characteristics (implant A: turned/implant B: TiUnite; NobelBiocare AB) were placed pairwise in the right side of the mandible 3 months after tooth extraction in five dogs. Experimental periodontitis and peri-implantitis were initiated 3 months later by ligature placement around implants and mandibular premolars and plaque formation. The ligatures were removed after 10 weeks. Microbial samples were obtained using paper points immediately after ligature removal, at 10 and 25 weeks after ligature removal. The microbiological analysis was performed by "checkerboard" DNA-DNA hybridization, including a panel of 16 bacterial species. The amount of bone loss that occurred during the period following ligature removal was significantly larger at implants with a modified surface than at implants with a turned surface and at teeth. The microbiological analysis revealed that the total bacterial load increased during the period following ligature removal and established an anaerobic Gram-negative microflora. It is suggested that the large variation in regard to the microbial profiles makes interpretation of a correlation between disease progression and microbial profiles difficult. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Tomotake, Yoritoki; Ishida, Osamu; Kanitani, Hideo; Ichikawa, Tetsuo
2002-01-01
This article describes a new procedure for immediate implant-supported oral rehabilitation using a photocurable resin skull model and a laser-welding apparatus. Preoperatively, the framework was fabricated on a photocurable resin skull model produced from a CT scan and individually designed guide template. The implants were immediately placed using the guide template; laser welding connected the components of framework. Despite the custom-made prosthesis, the total treatment from implant placement to superstructure placement can be completed within only 1 day. This procedure for immediate implant-supported oral rehabilitation using a photocurable resin skull model and a laser-welding apparatus may be useful for any implant system and patient.
Cardaropoli, Daniele; Tamagnone, Lorenzo; Roffredo, Alessandro; Gaveglio, Lorena
2015-01-01
In the maxillary arch from premolar to premolar, 26 single dental implants were inserted in fresh extraction sockets and immediately provisionalized. The bone-to-implant gap was grafted with a bovine bone mineral. After 3 months, definitive ceramic crowns were placed. At baseline and after 1 year, the soft tissue horizontal width, mesiodistal papillary level, midfacial gingival level, and pink esthetic score were evaluated. No statistical differences were found between baseline and 1 year for all parameters. Immediate single-tooth implants, with immediate restoration, are capable of maintaining the soft tissue contour and esthetics compared to the pretreatment status.
Development of implant loading device for animal study about various loading protocol: a pilot study
Yoon, Joon-Ho; Park, Young-Bum; Cho, Yuna; Kim, Chang-Sung; Choi, Seong-Ho; Moon, Hong-Seok; Lee, Keun-Woo
2012-01-01
PURPOSE The aims of this pilot study were to introduce implant loading devices designed for animal study and to evaluate the validity of the load transmission ability of the loading devices. MATERIALS AND METHODS Implant loading devices were specially designed and fabricated with two implant abutments and cast metal bars, and orthodontic expansion screw. In six Beagles, all premolars were extracted and two implants were placed in each side of the mandibles. The loading device was inserted two weeks after the implant placement. According to the loading protocol, the load was applied to the implants with different time and method,simulating early, progressive, and delayed loading. The implants were clinically evaluated and the loading devices were removed and replaced to the master cast, followed by stress-strain analysis. Descriptive statistics of remained strain (µε) was evaluated after repeating three cycles of the loading device activation. Statistic analysis was performed using nonparametric, independent t-test with 5% significance level and Friedman's test was also used for verification. RESULTS The loading devices were in good action. However, four implants in three Beagles showed loss of osseointegration. In stress-strain analysis, loading devices showed similar amount of increase in the remained strain after applying 1-unit load for three times. CONCLUSION Specialized design of the implant loading device was introduced. The loading device applied similar amount of loads near the implant after each 1-unit loading. However, the direction of the loads was not parallel to the long axis of the implants as predicted before the study. PMID:23236575
Survival of Implants in Immediate Extraction Sockets of Anterior Teeth: Early Clinical Results
Sabir, Mohammad
2015-01-01
Background The aims and objectives of this study were placement of implants in freshly extracted sockets of anterior teeth and to evaluate the implant stability, peri-implant radiolucency and gingival inflammation around implant over a short period of 30 months. Materials and Methods A total of 12 patients (8 male and 4 female), ranging in the age from 20 to 50 years, from March 2007 to June 2007, were evaluated for immediate implant placement into 22 fresh extraction sockets. Only maxillary and mandibular anterior teeth/roots (central incisors, lateral incisors and canines) were considered for replacement with implants. One piece implant with integrated abutment and integrated surface, non-submerged, threaded and tapered at apical 5 mm, sand-blasted and acid etched surfaced implants (HI-TEC TRX-OP Implants of Life Care Company) were used. Results The mobility was not present in any of the implants at all the follow up visits. There were 2 implants at 6 month, 1 implant at 12 month, 1 implant at 18 month visits, showing peri-implant radiolucency at some sites at bone to implant contact site. Severe gingival inflammation was not observed in any of the implant site. At every follow-up visit, every implant met the criteria of success and none was found to be failed over a 30 months duration i.e. 100% success rate was achieved by implants in immediate extraction socket. Conclusion The success rate of implant survival in this study was found 100%. These implants have fulfilled all the criteria of implant success and based on the defined criteria, the success rate of implants placed in immediate extraction sockets of anterior teeth compared favorably with the conventional implants. The early results of the present study showed that high survival rates with the implants in immediate extraction sockets can be achieved. PMID:26266220
Akça, Kıvanç; Eser, Atılım; Çavuşoğlu, Yeliz; Sağırkaya, Elçin; Çehreli, Murat Cavit
2015-05-01
The aim of this study was to investigate conventionally and early loaded titanium and titanium-zirconium alloy implants by three-dimensional finite element stress analysis. Three-dimensional model of a dental implant was created and a thread area was established as a region of interest in trabecular bone to study a localized part of the global model with a refined mesh. The peri-implant tissues around conventionally loaded (model 1) and early loaded (model 2) implants were implemented and were used to explore principal stresses, displacement values, and equivalent strains in the peri-implant region of titanium and titanium-zirconium implants under static load of 300 N with or without 30° inclination applied on top of the abutment surface. Under axial loading, principal stresses in both models were comparable for both implants and models. Under oblique loading, principal stresses around titanium-zirconium implants were slightly higher in both models. Comparable stress magnitudes were observed in both models. The displacement values and equivalent strain amplitudes around both implants and models were similar. Peri-implant bone around titanium and titanium-zirconium implants experiences similar stress magnitudes coupled with intraosseous implant displacement values under conventional loading and early loading simulations. Titanium-zirconium implants have biomechanical outcome comparable to conventional titanium implants under conventional loading and early loading.
Fu, Qian; Bellare, Anuj; Cui, Yajun; Cheng, Bingkun; Xu, Shanshan; Kong, Liang
2017-06-01
Owing to simplify the operation and shorten the overall duration of treatment, immediate implantation earned much satisfactory from patients and dentists. The results of immediate implantation determined by osseointegration, we fabricated a micro/nanotextured titanium implants to improve osseointegration immediately after tooth extraction. The aim of this study was to investigate the effect of hierarchical micro/nanotextured titanium implant on osseointegration immediately after tooth extraction. The micro/nanotextured titanium implants were fabricated by etching with 0.5 wt% hydrofluoric (HF) acid followed by anodization in HF electrolytes. Implants with a machined surface as well as implants a microtextured surface prepared by 0.5 wt% HF etching served as control groups. The machined, microtextured, and micro/nanotextured implants were inserted into fresh sockets immediately after tooth extraction in beagle dogs. Twelve weeks after implantation, the animals were sacrificed for micro-CT scanning, histological analysis and biomechanical test. The micro-CT imaging revealed that the bone volume/total volume (BV/TV) and trabecular thickness (Tb.Th) in the micro/nanotextured group was significantly higher than that in the machined group and microtextured group, and the trabecular separation (Tb.Sp) in the micro/nanotextured group was significantly lower than that in the other groups. For the histological analysis, the bone-to-implant contact in the machined, micro and micro/nanotextured groups were 47.13 ± 6.2%, 54.29 ± 4.18%, and 63.38 ± 7.63%, respectively, and the differences significant. The maximum pull-out force in the machined, micro, and micro/nanotextured groups were 216.58 ± 38.71 N, 259.42 ± 28.93 N, and 284.73 ± 47.09 N, respectively. The results indicated that implants with a hierarchical micro/nanotextured can promote osseointegration immediately after tooth extraction. © 2016 Wiley Periodicals, Inc.
Averbach, Sarah; Kakaire, Othman; Kayiga, Herbert; Lester, Felicia; Sokoloff, Abby; Byamugisha, Josaphat; Dehlendorf, Christine; Steinauer, Jody
2017-11-01
Use of long-acting, highly effective contraception has the potential to improve women's ability to avoid short interpregnancy intervals, which are associated with an increased risk of maternal morbidity and mortality, and preterm delivery. In Uganda, contraceptive implants are not routinely available during the immediate postpartum period. The purpose of this study was to compare the proportion of women using levonorgestrel contraceptive implants at 6 months after delivery in women randomized to immediate or delayed insertion. This was a randomized controlled trial among women in Kampala, Uganda. Women who desired contraceptive implants were randomly assigned to insertion of a 2-rod contraceptive implant system containing 75 mg of levonorgestrel immediately following delivery (within 5 days of delivery and before discharge from the hospital) or delayed insertion (6 weeks postpartum). The primary outcome was implant utilization at 6 months postpartum. From June to October 2015, 205 women were randomized, 103 to the immediate group and 102 to the delayed group. Ninety-three percent completed the 6 month follow-up visit. At 6 months, implant use was higher in the immediate group compared with the delayed group (97% vs 68%; P < .001), as was the use of any highly effective contraceptive (98% vs 81%; P = .001). Women in the immediate group were more satisfied with the timing of implant placement. If given the choice, 81% of women in the immediate group and 63% of women in the delayed group would choose the same timing of placement again (P = .01). There were no serious adverse events in either group. Offering women the option of initiating contraceptive implants in the immediate postpartum period has the potential to increase contraceptive utilization, decrease unwanted pregnancies, prevent short interpregnancy intervals, and help women achieve their reproductive goals. Copyright © 2017 Elsevier Inc. All rights reserved.
[Intramedullary stabilisation of clavicula fractures].
Prokop, A; Schiffer, G; Jubel, A; Chmielnicki, M
2013-10-01
With an incidence of 64/100,000, clavicular shaft fractures are one of the most common fractures. Intramedullary fixation with Prevot nails was initially reported in the late 1990s. This procedure offers minimally invasive stabilization of the fracture, thus enabling immediate mobilization and rapid loading capacity. Using a case study, the positioning and procedure are demonstrated on video. The intramedullary implant accommodates the varying tension loading of the clavicle. This treatment is ideal for clavicular fractures with 2-3 fragments. Compared to patients treated conservatively, operated patients achieve more rapid and improved mobility. Employment disability is shorter, and malunion occurs less frequently. Georg Thieme Verlag KG Stuttgart · New York.
A Numeric Analysis of Bone Density in the Edentulous Interforaminal Region.
Tavitian, Patrick; Ruquet, Michel; Mensé, Chloe; Nicolas, Emmanuel; Hue, Olivier
The purpose of this study was to assess the density of interforaminal bone using quantitative computed tomography (QCT) in simulated case histories to be prescribed an All-on-Five fixed implant treatment protocol. QCT scans from 30 edentulous patients (15 men and 15 women; mean age 63.33 ± 9.3 years) were analyzed using the Nobel Clinician software. Densities (in Hounsfield units [HU]) were recorded at the neck, middle part of the body, and apex of the lingual and buccal parts of proposed implant sites. The highest bone densities were measured at the neck of the implant (1,187 ± 382 HU), with lower densities at the apex (774 ± 571 HU) (P < .01). Bone densities decreased on the lingual interforaminal portion of the implant, especially on the two intermediate implants. Bone density was lower in women (917 ± 510 HU) than in men (1,095 ± 601 HU) (P < .01). The interforaminal measured bone densities are lower on the paramedian region of the symphysis and in women. However, these levels are in accordance with immediate loading with a fixed partial denture.
Effect of cyclic loading and retightening on reverse torque value in external and internal implants.
Cho, Woong-Rae; Huh, Yoon-Hyuk; Park, Chan-Jin; Cho, Lee-Ra
2015-08-01
The aim of this study was to evaluate the effect of cyclic loading and screw retightening on reverse torque value (RTV) in external and internal type implants. Cement-retained abutments were connected with 30 Ncm torque to external and internal type implants. Experimental groups were classified according to implant connection type and retightening/loading protocol. In groups with no retightening, RTV was evaluated after cyclic loading for 100,000 cycles. In groups with retightening, RTV was measured after 3, 10, 100 cycles as well as every 20,000 cycles until 100,000 cycles of loading. Every group showed decreased RTV after cyclic loading. Before and after cyclic loading, external type implants had significantly higher RTVs than internal type implants. In external type implants, retightening did not affect the decrease in RTV. In contrast, retightening 5 times and retightening after 10 cycles of dynamic loading was effective for maintaining RTV in internal type implants. Retightening of screws is more effective in internal type implants than external type implants. Retightening of screws is recommended in the early stage of functional loading.
Changes in passive tactile sensibility associated with dental implants following their placement.
El-Sheikh, Ali M; Hobkirk, John A; Howell, Peter G T; Gilthorpe, Mark S
2003-01-01
This study investigated the changes that might occur in passive tactile sensibility during a period of 3 months following Implant placement in a group of edentulous subjects treated with dental implants. The effect of changing the velocity of force application on passive tactile sensibility was also investigated. Five edentulous subjects who had been treated (as a part of an immediate loading study) with 2 or more Nobel Biocare dental implants in the anterior mandible were studied. Pushing forces were applied directly and perpendicular to the long axes of the abutments until the subjects felt the first sensation of pressure, using a computer-controlled, custom-made device. The force was measured with an integral transducer. The applied force had a ramped staircase pattern, which was used at 2 different tip velocities. The measurements were taken on 4 occasions: 1, 2, 4, and 12 weeks after fitting the abutments. Statistical analysis, using multilevel modeling, demonstrated that there was a significant decrease In the tactile threshold over successive weeks following implant placement. It also demonstrated that high velocity exhibited a higher threshold than low velocity. It could be concluded that there was a significant increase In passive tactile sensibility during the healing phase following implant placement.
Arora, Himanshu; Khzam, Nabil; Roberts, David; Bruce, William L; Ivanovski, Saso
2017-08-01
Immediate implant placement followed by an immediate restoration has proven to be a viable technique in the anterior maxillary region. This prospective study evaluated the mid-long term (2-5 years) tissue changes around immediately placed and restored implants in the anterior maxilla using flapless surgery and simultaneous hard tissue augmentation. Thirty AstraTech implants were immediately placed in 30 patients, followed by the delivery of an immediate provisional restoration on the same day. All participating 30 patients underwent the same treatment strategy that involved flapless removal of a failing maxillary anterior tooth, immediate implant placement, simultaneous augmentation with a deproteinized particulate xenograft, followed by the connection of a screw-retained provisional restoration. Radiographs and photographs were used to measure hard and soft tissue changes. Aesthetic evaluation was performed using the Pink Esthetic Score (PES). All implants remained osseointegrated during the follow up period of 2-5 years (mean 47 ± 15 months). Twelve of the thirty patients completed the 5 year follow up. Radiographic evaluation revealed average gains in bone levels of 0.18 and 0.34 mm mesially and distally, respectively. Soft tissue evaluation showed a mean tissue loss of 0.05 ± 0.64 mm and 0.16 ± 0.63 mm at the mesial and distal papillae, respectively, while mid-facial mucosal recession was 0.29 ± 0.74 mm. A significant improvement in the Pink Esthetic Scores was seen at the final follow-up (mean PES 11.50), as compared to the baseline (mean PES 10.27) (P = .001). In addition to a favorable implant success rate and peri-implant bony response, the soft tissue levels and overall aesthetics around single immediately placed and restored implants can also be maintained in the mid-long term. © 2017 Wiley Periodicals, Inc.
Immediate placement and restoration of dental implants in the esthetic region: clinical case series.
Khzam, Nabil; Mattheos, Nikos; Roberts, David; Bruce, William L; Ivanovski, Saso
2014-01-01
The objective of this study was to assess the hard and soft tissue changes following immediate placement and provisional restoration of single-tooth implants in the aesthetic zone. Thirteen patients with immediately placed and restored implants were included in this study. All participating patients underwent the same treatment strategy that involved removal of the failed tooth, flapless surgery, immediate implant placement, and connection of a screw-retained provisional restoration. Three months following implant placement, the temporary crowns were replaced by the definitive restorations. Implant survival rates, and hard and soft tissue changes were measured using periapical X-rays and photographs. The range of the observation period was between 12 and 37 months with a mean period of 23.2 ± 7.6 months. At the time of follow-up, all implants were present with no complications. Radiographic evaluation revealed a mean mesial bone gain of 1.20 ± 1.01 mm and a mean distal bone gain of 0.80 ± 1.14 mm, which reached statistical significance. The mean mid-buccal recession was 0.20 ± 0.78 mm, whereas the mesial and distal papillae height loss was 0.50 ± 1.26 mm and 0.30 ± 0.82 mm, respectively. The changes in the soft tissues did not reach statistical significance. Notwithstanding the limitation of a small sample size, this study shows that immediate implant placement and provisional restoration in the maxillary aesthetic zone can result in favorable treatment outcomes with regards to soft and hard tissues changes over a follow-up period of 23.2 ± 7.6 months. Most clinical trials investigating immediate implant placement and immediate restoration in the maxillary anterior zone have focused on implant survival and implant success, with particular emphasis on radiographically assessed hard tissues changes. However, this study assesses the soft tissue changes associated with this procedure, which is an important area of study given the esthetic demands of implant therapy in the maxillary anterior region. © 2013 Wiley Periodicals, Inc.
[Stress distribution in press-fit orthodontic microimplant bone interface].
Wu, Jian-chao; Huang, Ji-na; Zhao, Shi-fang; Xu, Xue-jun
2006-12-01
The goal of this study is to analyse the stress distribution in the press-fit microimplant-bone interface and its indications for immediate loading of orthodontic microimplant. Three-dimensional finite element models were created of a 20 mm section of posterior mandible simplified in isosceles trapezoid shape, 30 mm in height, 10mm in upper side width, 14 mm in lower side width,with a single microimplant, 1.2 mm in diameter, 6 mm in length embedded in the bone. The cortical bone thickness was assumed as 1.6 mm. Cortical and cancellous bone were modeled as transversely isotropic and linearly elastic materials. Titanium was modeled as isotropic and linearly elastic material. Perfect bonding was assumed at microimplant- bone interfaces. ANSYS 9.0 finite element analysis software was used to generate the simplified finite element models of the local mandible-implant complex. 0 mm, 0.05 mm and 0.1 mm press-fit were arbitrarily set to the implant-bone interface to mimic the situation of immediate placement of microimplant. Stresses in the microimplant-bone interface were calculated under these "press-fit". Stresses distributed mainly in the cortical bone interface. At Omm press-fit, the stress was 0 MPa. For 0.05mm press-fit, the stress was 1648 MPa in mesio-distal direction, 1782MPa in occluso-gingival direction;and for 0.1 mm, it reached 2012MPa in mesio-distal direction, 2110MPa in occluso-gingival direction. As the "press-fit" increased, the stresses increased accordingly. Values of initial stress in the microimplant-bone interface due to press-fit generated by immediately placed microimplant were very high in these limited and simplified three dimensional finite element models. It reminded us that the initial stress be taken into consideration when immediate loading of the microimplant is planned. Supported by Research Fund of Health Bureau of Zhejiang Province (2005B104).
Effect of cyclic loading and retightening on reverse torque value in external and internal implants
Cho, Woong-Rae; Huh, Yoon-Hyuk; Park, Chan-Jin
2015-01-01
PURPOSE The aim of this study was to evaluate the effect of cyclic loading and screw retightening on reverse torque value (RTV) in external and internal type implants. MATERIALS AND METHODS Cement-retained abutments were connected with 30 Ncm torque to external and internal type implants. Experimental groups were classified according to implant connection type and retightening/loading protocol. In groups with no retightening, RTV was evaluated after cyclic loading for 100,000 cycles. In groups with retightening, RTV was measured after 3, 10, 100 cycles as well as every 20,000 cycles until 100,000 cycles of loading. RESULTS Every group showed decreased RTV after cyclic loading. Before and after cyclic loading, external type implants had significantly higher RTVs than internal type implants. In external type implants, retightening did not affect the decrease in RTV. In contrast, retightening 5 times and retightening after 10 cycles of dynamic loading was effective for maintaining RTV in internal type implants. CONCLUSION Retightening of screws is more effective in internal type implants than external type implants. Retightening of screws is recommended in the early stage of functional loading. PMID:26330975
Platform switching: biomechanical evaluation using three-dimensional finite element analysis.
Tabata, Lucas Fernando; Rocha, Eduardo Passos; Barão, Valentim Adelino Ricardo; Assunção, Wirley Goncalves
2011-01-01
The objective of this study was to evaluate, using three-dimensional finite element analysis (3D FEA), the stress distribution in peri-implant bone tissue, implants, and prosthetic components of implant-supported single crowns with the use of the platform-switching concept. Three 3D finite element models were created to replicate an external-hexagonal implant system with peri-implant bone tissue in which three different implant-abutment configurations were represented. In the regular platform (RP) group, a regular 4.1-mm-diameter abutment (UCLA) was connected to regular 4.1-mm-diameter implant. The platform-switching (PS) group was simulated by the connection of a wide implant (5.0 mm diameter) to a regular 4.1-mm-diameter UCLA abutment. In the wide-platform (WP) group, a 5.0-mm-diameter UCLA abutment was connected to a 5.0-mm-diameter implant. An occlusal load of 100 N was applied either axially or obliquely on the models using ANSYS software. Both the increase in implant diameter and the use of platform switching played roles in stress reduction. The PS group presented lower stress values than the RP and WP groups for bone and implant. In the peri-implant area, cortical bone exhibited a higher stress concentration than the trabecular bone in all models and both loading situations. Under oblique loading, higher intensity and greater distribution of stress were observed than under axial loading. Platform switching reduced von Mises (17.5% and 9.3% for axial and oblique loads, respectively), minimum (compressive) (19.4% for axial load and 21.9% for oblique load), and maximum (tensile) principal stress values (46.6% for axial load and 26.7% for oblique load) in the peri-implant bone tissue. Platform switching led to improved biomechanical stress distribution in peri-implant bone tissue. Oblique loads resulted in higher stress concentrations than axial loads for all models. Wide-diameter implants had a large influence in reducing stress values in the implant system.
Immediate provisional restoration of a single-tooth implant in the esthetic zone: a case report.
Fu, Po-Sung; Wu, Yi-Min; Tsai, Ching-Fang; Huang, Ta-Ko; Chen, Wen-Cheng; Hung, Chun-Cheng
2011-02-01
Immediate implant restoration of single implants may demonstrate a positive effect on peri-implant soft tissue. Placement of a provisional restoration following implant surgery can create soft tissue contours that resemble normal gingival topography before placement of the definitive prosthesis. This article describes a staged approach of the mandibular permanent right central incisor, which was congenital missing. The proper space for restoration of the missing incisor was created through orthodontic treatment. The scheduled implant site was reconstructed using autogenous bone harvested from the chin region. After a healing period of four months, an implant was installed with the connection of a fixed provisional crown to a prefabricated temporary abutment. The soft tissue around the implant healed according to the contours of the provisional restoration and the emergence profile was used to duplicate the definitive restoration. Peri-implant esthetics was achieved through the staged approach and immediate restoration of the implant. Copyright © 2011. Published by Elsevier B.V.
de Barros E Lima Bueno, Renan; Dias, Ana Paula; Ponce, Katia J; Wazen, Rima; Brunski, John B; Nanci, Antonio
2018-05-31
When bone implants are loaded, they are inevitably subjected to displacement relative to bone. Such micromotion generates stress/strain states at the interface that can cause beneficial or detrimental sequels. The objective of this study is to better understand the mechanobiology of bone healing at the tissue-implant interface during repeated loading. Machined screw shaped Ti implants were placed in rat tibiae in a hole slightly bigger than the implant diameter. Implants were held stable by a specially-designed bone plate that permits controlled loading. Three loading regimens were applied, (a) zero loading, (b) one daily loading session of 60 cycles with an axial force of 1.5 N/cycle for 7 days, and (c) two such daily sessions with the same axial force also for 7 days. Finite element analysis was used to characterize the mechanobiological conditions produced by the loading sessions. After 7 days, the implants with surrounding interfacial tissue were harvested and processed for histological, histomorphometric and DNA microarray analyses. Histomorphometric analyses revealed that the group subjected to repeated loading sessions exhibited a significant decrease in bone-implant contact and increase in bone-implant distance, as compared to unloaded implants and those subjected to only one loading session. Gene expression profiles differed during osseointegration between all groups mainly with respect to inflammatory and unidentified gene categories. The results indicate that increasing the daily cyclic loading of implants induces deleterious changes in the bone healing response, most likely due to the accumulation of tissue damage and associated inflammatory reaction at the bone-implant interface. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
Lorenz, Jonas; Korzinskas, Tadas; Chia, Poju; Maawi, Sarah Al; Eichler, Katrin; Sader, Robert A; Ghanaati, Shahram
2018-02-01
The present prospective randomized split-mouth trial reports on the 3-year clinical and radiological follow-up investigation of implants placed 7 months after sinus augmentation with 2 different bone substitute materials. The aim of the study was to complete the histologic observation of cellular reactions by analyses of the implants and the volumetric changes of the augmented bone substitute materials. A sinus augmentation split-mouth trial was performed in 14 patients with the synthetic bone substitute material Nanobone (NB) and the xenogeneic Bio-Oss (BO). Changes in volume and density of the augmented biomaterials were investigated by analysis of computed tomography scans, taken immediately after augmentation and after 7 months. Clinical implant parameters were assessed after 3 years of loading. Both bone substitute materials underwent nonsignificant volume reduction and significant increase in bone density over an integration period of 7 months. No significant differences concerning volume and bone density were observed between the groups. Three years after loading, 51 of 53 implants were in situ with no peri-implant infections, and only a few soft-tissue variations were present. The present prospective randomized study showed that no differences could be observed clinically and radiologically. Accordingly, it seems that both biomaterials, independent of their physicochemical composition, enable clinical success and long-time stability for dental implants. Interestingly, the histological results showed distinct differences in cellular reactions: While the xenogeneic BO induced a mild tissue reaction with only few multinucleated giant cells and comparably low vascularization, the synthetic NB induced a multinucleated giant cell-triggered tissue reaction with an increase of vascularization. Thus, the present study showed that a combination analysis-histological, clinical, and radiological-is necessary for a detailed assessment of a biomaterial's quality for clinical application.
Block, Jonathan; Matalon, Shlomo; Tanase, Gabriela; Ormianer, Zeev
2017-08-01
This study investigated strain levels during and after implant insertion, and during and after simulated mastication, in splinted and nonsplinted restorations with different occlusal schemes. Fresh bovine bone resembling type I jawbone was collected. Strain gauges were placed at each implant's neck, one horizontally and one vertically. Strains at and after implant insertion were recorded. The restoration was loaded with cyclic load simulating mastication. Loading and residual strains were recorded for 6 experimental loading types. At and after implant insertion, high horizontal strains were measured. Full splint loading presented higher vertical compared with horizontal strains (P < 0.05). Segmented cross-arch splint showed higher horizontal strains (P < 0.05). Premolar loading guidance presented the most favorable loading and residual strain results (P < 0.05). Splinting implant restorations may reduce strain levels at implant neck area and provide preferable strain distribution during cyclic loading.
Rohlmann, Antonius; Gabel, Udo; Graichen, Friedmar; Bender, Alwina; Bergmann, Georg
2007-06-01
Realistic loads on a spinal implant are required among others for optimization of implant design and preclinical testing. In addition, such data may help to choose the optimal physiotherapy program for patients with such an implant and to evaluate the efficacy of aids like braces or crutches. Presently, no implant is available that can measure loads in the anterior spinal column during activities of daily life. Therefore, an implant instrumented for in vivo load measurement was developed for vertebral body replacement. The aim of this paper is to describe in detail a telemeterized implant that measures forces and moments acting on it. Six load sensors, a nine-channel telemetry unit and a coil for inductive power supply of the electronic circuits were integrated into a modified vertebral body replacement (Synex). The instrumented part of the implant is hermetically sealed. Patients are videotaped during measurements, and implant loads are displayed on and off line. The average accuracy of load measurement is better than 2% for force and 5% for moment components with reference to the maximum value of 3000 N and 20 Nm, respectively. The measuring implant described here will provide additional information on spinal loads.
Cafiero, Carlo; Marenzi, Gaetano; Blasi, Andrea; Siciliano, Vincenzo Iorio; Nicolò, Michele; Sammartino, Gilberto
2013-10-01
To assess soft and hard tissues healing at immediate transmucosal implants placed into maxillary molar region with collagen membranes uncovered. Twenty subjects received 20 immediate transmucosal implants placed in maxillary molar extraction sockets. Periimplant marginal defects were treated according to the principles of guided bone regeneration by means of deproteinized bovine bone mineral particles in conjunction with collagen membrane. Flaps were repositioned and sutured, allowing nonsubmerged, transmucosal soft tissues healing. The collagen membranes adapted around implant neck were uncovered. No implants were lost during the 1-year observation period yielding a survival rate of 100%. No postsurgical wound healing complications were observed. No degranulation of grafting material was reported. The results of this 12-month prospective study showed that the exposure of collagen membrane at time of the flap suturing does not represent a limitation for the soft and hard tissues healing at immediate transmucosal implants placed into maxillary molar extraction sites.
Lee, Ji-Hye; Huh, Yoon-Hyuk; Park, Chan-Jin; Cho, Lee-Ra
2016-01-01
To evaluate the effect of implant coronal wall thickness on load-bearing capacity and screw joint stability. Experimental implants were customized after investigation of the thinnest coronal wall thickness of commercially available implant systems with a regular platform diameter. Implants with four coronal wall thicknesses (0.2, 0.3, 0.4, and 0.5 mm) were fabricated. Three sets of tests were performed. The first set was a failure test to evaluate load-bearing capacity and elastic limit. The second and third sets were cyclic and static loading tests. After abutment screw tightening of each implant, vertical cyclic loading of 250 N or static loading from 250 to 800 N was applied. Coronal diameter expansion, axial displacement, and removal torque values of the implants were compared. Repeated measures analysis of variance (ANOVA) was used for statistical analysis (α = .05). Implants with 0.2-mm coronal wall thickness demonstrated significantly low load-bearing capacity and elastic limit (both P < .05). These implants also showed significantly large coronal diameter expansion and axial displacement after screw tightening (both P < .05). Greater vertical load and thinner coronal wall thickness significantly increased coronal diameter expansion of the implant, axial displacement of the abutment, and removal torque loss of the abutment screw (all P < .05). Implant coronal wall thickness of 0.2 mm produces significantly inferior load-bearing capacity and screw joint stability.
Huang, Hairong; Wismeijer, Daniel; Shao, Xianhong; Wu, Gang
2016-01-01
Objectives The objective of this study is to mathematically evaluate the influence of multiple factors on implant stability quotient values in clinical practice. Patients and methods Resonance frequency analysis was performed at T1 (measured immediately at the time of implant placement) and at T2 (measured before dental restoration) in 177 patients (329 implants). Using a multivariate linear regression model, we analyzed the influence of the following eleven candidate factors: sex, age, maxillary/mandibular location, bone type, immediate/delayed implantation, bone grafting (presence or absence), insertion torque, I-/II-stage healing pattern, implant diameter, implant length, and T1–T2 time interval. Results The following factors were identified to significantly influence the implant stability quotient (ISQ) values at T1: insertion torque, bone grafting, I-/II-stage healing pattern, immediate/delayed implantation, maxillary/mandibular location, implant diameter, and sex. In contrast, the ISQ values at T2 were significantly influenced only by three factors: implant diameter, T1–T2 time interval, and insertion torque. Conclusion Among the eleven candidate factors, seven key factors were found to influence the T1-ISQ values, while only three key factors influenced the T2-ISQ values. Both T1 and T2-ISQ values were found to be influenced by implant diameter and insertion torque. T1 was influenced specifically by the sex of the patient, the location (maxillary or mandibular), the implantation mode (immediate/delayed implantation), the healing stage, and the absence or presence of bone graft materials. PMID:27785040
Can Time of Implant Placement influence Bone Remodeling?
Rafael, Caroline F; Passoni, Bernardo; Araúio, Carlos; de Araúio, Maria A; Benfatti, César; Volpato, Claudia
2016-04-01
Since the alveolar process is tissue "dental dependent," after the extraction of the dental element, this process suffers some degree of atrophy during the healing process, which can be reduced with the installation of immediate implants, aiming to maintain the original bone architecture. The aim of this study was to investigate the influence of the time of implant placement on bone formation around them. Seven dogs were selected and randomly divided into two groups: Group 1, where implants were placed immediately after extraction of two lower premolars without flap elevation, and group 2, where implants were delayed by 4 months after extractions. Each group received 14 implants, and 4 months after the second surgery, the samples were processed and analyzed histomorphometrically. A mean average analysis and the Kruskal-Wallis test (p < 0.05) were performed. The buccal bone-implant contact (BIC) mean average was found larger in immediate implants (42.61%) compared with delayed implants (37.69%). Group 1 had statistically higher outcomes in bone formation and BIC on the buccal bone wall. It was concluded that performing immediate implants with the palatal approach technique and leaving a buccal GAP enables a higher or at least equal rate to BIC and bone area around them, when compared with delayed implants. Actually, the patients and dentists want to do a shorter treatment with satisfactory results, but it is necessary to understand whether different times of implant placement can influence the results and longevity of the treatment.
Cortes, Arthur Rodriguez Gonzalez; Eimar, Hazem; Barbosa, Jorge de Sá; Costa, Claudio; Arita, Emiko Saito; Tamimi, Faleh
2015-05-01
Subjective radiographic classifications of alveolar bone have been proposed and correlated with implant insertion torque (IT). The present diagnostic study aims to identify quantitative bone features influencing IT and to use these findings to develop an objective radiographic classification for predicting IT. Demographics, panoramic radiographs (taken at the beginning of dental treatment), and cone-beam computed tomographic scans (taken for implant surgical planning) of 25 patients receiving 31 implants were analyzed. Bone samples retrieved from implant sites were assessed with dual x-ray absorptiometry, microcomputed tomography, and histology. Odds ratio, sensitivity, and specificity of all variables to predict high peak IT were assessed. A ridge cortical thickness >0.75 mm and a normal appearance of the inferior mandibular cortex were the most sensitive variables for predicting high peak IT (87.5% and 75%, respectively). A classification based on the combination of both variables presented high sensitivity (90.9%) and specificity (100%) for predicting IT. Within the limitations of this study, the results suggest that it is possible to predict IT accurately based on radiographic findings of the patient. This could be useful in the treatment plan of immediate loading cases.
Bell, Christopher Lincoln; Diehl, David; Bell, Brian Michael; Bell, Robert E
2011-06-01
The purpose of this study was to evaluate the success of dental implants placed immediately into extraction sites in the presence of chronic periapical pathology. The charts of 655 patients who had implants immediately placed into fresh extraction sites were reviewed for the presence or absence of periapical radiolucencies. A total of 922 implants were included. Of the 922 implants, 285 were immediately placed into sockets that had chronic periapical infections. The remaining 637 implants, without signs of periapical pathology, were used as the control group. Success of the implants was defined as successful osseointegration, successful restoration, and absence of evidence of bone loss or peri-implantitis. Other variables such as age, gender, smoking, diabetes, bisphosphonate use, lucencies of adjacent teeth, and implant stability at the time of placement were also evaluated. Of the 922 implants, 285 were placed into sockets with periapical radiolucencies. The success rate of implants placed in the study group was 97.5%, whereas the success rate of the control group was 98.7%. The difference was not found to be statistically significant. The mean follow-up was 19.75 months, with a maximum of 93 months and a minimum of 3 months. A statistically higher failure rate was found for implants placed adjacent to retained teeth with periapical pathology. The placement of implants in sockets affected by chronic periapical pathology can be considered a safe and viable treatment option. There is a risk of implant failure when placing implants adjacent to teeth with periapical radiolucencies. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Park, Youngsoo; Choi, Kyoung Wook; Chung, Kyu-Jin; Kim, Tae Gon; Kim, Yong-Ha
2016-01-01
Background The use of acellular dermal matrix (ADM) in implant-based immediate breast reconstruction has been increasing. The current ADMs available for breast reconstruction are offered as aseptic or sterile. No published studies have compared aseptic and sterile ADM in implant-based immediate breast reconstruction. The authors performed a retrospective study to evaluate the outcomes of aseptic versus sterile ADM in implant-based immediate breast reconstruction. Methods Implant-based immediate breast reconstructions with ADM conducted between April 2013 and January 2016 were included. The patients were divided into 2 groups: the aseptic ADM (AlloDerm) group and the sterile ADM (MegaDerm) group. Archived records were reviewed for demographic data and postoperative complication types and frequencies. The complications included were infection, flap necrosis, capsular contracture, seroma, hematoma, and explantation for any cause. Results Twenty patients were reconstructed with aseptic ADM, and 68 patients with sterile ADM. Rates of infection (15.0% vs. 10.3%), flap necrosis (5.0% vs. 7.4%), capsular contracture (20.0% vs. 14.7%), seroma (10.0% vs. 14.7%), hematoma (0% vs. 1.5%), and explantation (10.0% vs. 8.8%) were not significantly different in the 2 groups. Conclusions Sterile ADM did not provide better results regarding infectious complications than aseptic ADM in implant-based immediate breast reconstruction. PMID:27896182
The effect of platelet-rich fibrin on implant stability.
Öncü, Elif; Alaaddinoğlu, E Emine
2015-01-01
Achieving accelerated implant osseointegration could make immediate or early loading of implants more predictable. Platelet-rich fibrin (PRF) is frequently used to accelerate soft and hard tissue healing. The activated platelets in PRF release growth factors, resulting in cellular proliferation, collagen synthesis, and osteoid production. The aim of this study was to compare the stability of dental implants inserted in a one-stage surgical protocol with or without PRF application. Twenty healthy patients with adequate alveolar bone and two or more adjacent missing teeth extracted at least 6 months previously were included in this study. A minimum of two tapered implants (Ankylos, Dentsply/Friadent) were placed in each patient. After surgical preparation of the implant sockets, PRF that had been prepared preoperatively was placed randomly into one of the sockets (PRF+). The acellular plasma portion of PRF was used to wet the implant placed into the PRF-coated socket. Resonance frequency measurements were made after implant placement and at 1 week and 1 month postoperatively. Mean implant stability quotients (ISQs) of the PRF+ implants was 69.3 ± 10.5, and mean ISQs for the PRF- implants was 64.5 ± 12.2 at the end of the first week. The mean ISQs at 4 weeks postoperatively were 77.1 ± 7.1 for the PRF+ group and 70.5 ± 7.7 for the PRF- group. In this study, PRF application increased implant stability during the early healing period, as evidenced by higher ISQ values. Simple application of this material seems to provide faster osseointegration.
Liu, Jingyin; Pan, Shaoxia; Dong, Jing; Mo, Zhongjun; Fan, Yubo; Feng, Hailan
2013-03-01
The aim of this study was to evaluate strain distribution in peri-implant bone, stress in the abutments and denture stability of mandibular overdentures anchored by different numbers of implants under different loading conditions, through three-dimensional finite element analysis (3D FEA). Four 3D finite element models of mandibular overdentures were established, using between one and four Straumann implants with Locator attachments. Three types of load were applied to the overdenture in each model: 100N vertical and inclined loads on the left first molar and a 100N vertical load on the lower incisors. The biomechanical behaviours of peri-implant bone, implants, abutments and overdentures were recorded. Under vertical load on the lower incisors, the single-implant overdenture rotated over the implant from side to side, and no obvious increase of strain was found in peri-implant bone. Under the same loading conditions, the two-implant-retained overdenture showed more apparent rotation around the fulcrum line passing through the two implants, and the maximum equivalent stress in the abutments was higher than in the other models. In the three-implant-supported overdenture, no strain concentration was found in cortical bone around the middle implant under three loading conditions. Single-implant-retained mandibular overdentures do not show damaging strain concentration in the bone around the only implant and may be a cost-effective treatment option for edentulous patients. A third implant can be placed between the original two when patients rehabilitated by two-implant overdentures report constant and obvious denture rotation around the fulcrum line. Copyright © 2012 Elsevier Ltd. All rights reserved.
Quek, H C; Tan, Keson B; Nicholls, Jack I
2008-01-01
Biomechanical load-fatigue performance data on single-tooth implant systems with different implant-abutment interface designs is lacking in the literature. This study evaluated the load fatigue performance of 4 implant-abutment interface designs (Brånemark-CeraOne; 3i Osseotite-STA abutment; Replace Select-Easy abutment; and Lifecore Stage-1-COC abutment system). The number of load cycles to fatigue failure of 4 implant-abutment designs was tested with a custom rotational load fatigue machine. The effect of increasing and decreasing the tightening torque by 20% respectively on the load fatigue performance was also investigated. Three different tightening torque levels (recommended torque, -20% recommended torque, +20% recommended torque) were applied to the 4 implant systems. There were 12 test groups with 5 samples in each group. The rotational load fatigue machine subjected specimens to a sinusoidally applied 35 Ncm bending moment at a test frequency of 14 Hz. The number of cycles to failure was recorded. A cutoff of 5 x 10(6) cycles was applied as an upper limit. There were 2 implant failures and 1 abutment screw failure in the Brånemark group. Five abutment screw failures and 4 implant failures was recorded for the 3i system. The Replace Select system had 1 implant failure. Five cone screw failures were noted for the Lifecore system. Analysis of variance revealed no statistically significant difference in load cycles to failure for the 4 different implant-abutment systems torqued at recommended torque level. A statistically significant difference was found between the -20% torque group and the +20% torque group (P < .05) for the 3i system. Load fatigue performance and failure location is system specific and related to the design characteristics of the implant-abutment combination. It appeared that if the implant-abutment interface was maintained, load fatigue failure would occur at the weakest point of the implant. It is important to use the torque level recommended by the manufacturer.
Fürhauser, Rudolf; Mailath-Pokorny, Georg; Haas, Robert; Busenlechner, Dieter; Watzek, Georg; Pommer, Bernhard
2017-02-01
Implant esthetics may benefit from individualized zirconia abutments copying the emergence profile of the natural tooth and delivered within days after immediate implant insertion. To investigate the esthetic outcome of the Copy-Abutment technique using the Pink Esthetic Score (PES). A total of 77 patients with single-tooth implants in the anterior maxilla restored at the day of immediate implant placement using Copy-Abutments and provisional crowns were followed-up after 1 week, 1 month, 4 months, 6 months, 1, 2, 3, 4, and 5 years to assess implant esthetics. PES ranged between 7 and 14 (median: 13) and improved significantly between the 6 month and 1 year follow-up (p < .001), then remained stable up to the fifth year. Significant improvement was seen for the variables PES-6 soft tissue color (p = .002) and PES-7 soft tissue texture (p < .001) up to the 1 year follow-up, while PES-5 alveolar process deficiency deteriorated (p = .016). Mean mucosal recession was 0.26 ± 0.86 mm (range: 0-1.6) after 5 years and not related to gingival biotype. Copy-Abutments for immediate restoration of implants in the esthetic zone show satisfactory long-term esthetic outcomes. © 2016 Wiley Periodicals, Inc.
Cowett, Allison A; Ali, Rose; Cooper, Mary A; Evans, Mark; Conzuelo, Gabriel; Cremer, Miriam
2018-05-01
To compare the 6-month use rate of the etonogestrel implant placed immediately after dilation and evacuation (D&E) with placement 2-4 weeks postprocedure. This is a randomized controlled trial of women seeking abortion between 14 0/7 and 23 5/7 weeks of gestation and desiring the etonogestrel contraceptive implant at an urban family planning clinic. Participants were randomized to device insertion immediately after the D&E compared with delayed insertion in 2-4 weeks. The primary outcome was implant use rate at 6 months after insertion and was determined by follow-up phone interviews. Secondary outcomes included repeat pregnancy rates and method satisfaction. The sample size of 120 participants was calculated based on a power of 0.80 to demonstrate a 20% difference in implant use rates between groups assuming 40% of women overall are not using the device 6 months after the procedure. Between November 2015 and October 2016, 148 participants were enrolled. Seventy-three participants (49.3%) were randomized to and underwent immediate implant insertion after D&E. The remaining 75 (50.6%) were randomized to delayed insertion. There were no significant differences in sociodemographic characteristics between the groups. Placement rate was 100% in the immediate group compared with 42.7% in the delayed group (P<.01). At 6 months, 40 of 43 (93%) women from the immediate group who completed follow-up continued use of the implant, whereas 19 of 30 (63.3%) women from the delayed group who completed follow-up were using the device (P=.002). Follow-up rates were low at 58.9% in the immediate group compared with 40.0% in the delayed group. Women were more likely to be using the etonogestrel implant at 6 months after D&E if they underwent immediate compared with delayed insertion. The very high loss to follow-up rate makes it difficult to draw conclusions about acceptability of the device and pregnancy rates. ClinicalTrials.gov, 02037919.
Deliberador, Tatiana Miranda; Begnini, Gilmar José; Tomazinho, Flávia; Rezende, Carlos Eduardo Edwards; Florez, Fernando Luis Esteban; Leonardi, Denise Piotto
2018-03-01
Immediate placement and provisionalization of implants in fresh sockets has been previously demonstrated to be a predictable treatment in the restoration of non-recoverable teeth in the anterior regions of the maxilla. This article reports a clinical case in which an immediate implant placement protocol was used in combination with two distinct and sequential grafts (bovine bone and connective tissue, respectively) followed by immediate implant provisionalization using the patient's crown of an extracted tooth. Physical, clinical, and image examinations of the patient (female, 23 years old) revealed a maxillary central incisor (tooth No. 8) with slight mobility due the presence of extensive cervical resorption. The treatment proposed was the atraumatic extraction of the tooth followed by immediate implant placement and provisionalization. Two grafts (bovine bone and connective tissue) were used due to the presence of a very thin maxillary bone plate associated with a thin gingival biotype. The use of the extracted crown as a temporary crown after immediate implant placement resulted in immediate attainment of an esthetically pleasing outcome and long-term favorable results. The treatment protocol proposed can be efficiently used to immediately restore the patient's esthetics and function while maintaining the health, volume, and contours of gingival tissues over a 12-month follow-up period. Anterior teeth extractions typically require the execution of single-unit prostheses using dental materials of synthetic origin (such as polymers), which often are incapable of achieving the esthetic and physiological results patients expect. The use of the patient's own crown was demonstrated, which allowed good clinical results to be achieved and the natural shape and function of tissues to be maintained.
Raes, Stefanie; Cosyn, Jan; Noyelle, Anabel; Raes, Filiep; De Bruyn, Hugo
Recent systematic reviews point to the scarcity of single implants followed up longer than 5 years, and the incidence of biologic/technical complications is underreported. This prospective follow-up study documents 8- to 10-year clinical outcomes of immediately restored single implants in extraction sockets (immediate implant treatment [IIT]) and healed bone (conventional implant treatment [CIT]). Patients received a single, chemically modified, moderately rough titanium implant and a provisional crown on the day of surgery in the anterior maxilla (second premolar to second premolar). Provisional crowns were replaced by permanent crowns after 10 weeks. Implant survival, complications, crestal bone changes, plaque score, probing depth, and bleeding on probing were regularly recorded up to 10 years of follow-up. Of 16 patients who underwent IIT, 11 could be evaluated after 8 years. Of the 23 patients who received an implant in healed bone, 18 were finally evaluated. One implant failed in the IIT group at 12 weeks; all implants survived in the CIT group; 38% of the patients experienced at least one complication; 10% had one or more biologic complications, whereas 31% experienced one or more technical complications. There were no significant changes in crestal bone level from 1 to ≥ 8 years of follow-up for either group or between IIT and CIT at any time point (P ≥ .129). Only 6.9% (2 of 29) implants demonstrated progressive bone loss > 2 mm combined with pockets ≥ 6 mm. Immediately restored single implants in extraction sockets and healed ridges demonstrate good long-term outcomes in terms of implant survival, crestal bone loss, and peri-implant health. However, biologic and especially technical complications are common.
Effects of Untreated Periodontitis on Osseointegration of Dental Implants in a Beagle Dog Model.
Lee, Daehyun; Sohn, Byungjin; Kim, Kyoung Hwa; Kim, Sungtae; Koo, Ki-Tae; Kim, Tae-Il; Seol, Yang-Jo; Lee, Yong-Moo; Rhyu, In-Chul; Ku, Young
2016-10-01
There have been previous studies on the relationship between periodontitis and peri-implantitis, but limited information is available on how periodontitis affects osseointegration and wound healing of newly placed dental implants adjacent to natural teeth. The objective of the present experiment is to evaluate healing around dental implants adjacent to teeth with untreated experimental periodontitis. The study included six male beagle dogs. Scaling and plaque control procedures were performed on three dogs (control group). In the other three dogs (experimental group), retraction cords and ligature wires were placed subgingivally around all premolars and the first molars. Induced experimental periodontitis was confirmed after 3 months. Each control or experimental group was divided into two subgroups depending on the timing of implant placement (immediate/delayed). Twelve dental implants (two implants for each dog) were placed immediately, and the other 12 dental implants (two implants for each dog) were placed 2 months after extraction. The animals were sacrificed 2 months after implant placement. Histologic and histometric analyses were performed. Four implants (three from the immediate placement group and one from the delayed placement group) failed in the experimental group. There were significant differences in the percentage of bone-to-implant contact and marginal bone volume density between the control and experimental groups. Both parameters were significantly lower in the experimental group than in the control group (P <0.05). There was a tendency toward more marginal bone loss in the experimental group than the control group. Immediate placement of implants is associated with a higher failure rate compared with delayed placement. Untreated experimental periodontitis was correlated with compromised osseointegration in the implants with delayed placement.
Mounir, M; Atef, M; Abou-Elfetouh, A; Hakam, M M
2018-05-01
The aim of this study was to assess two new protocols for single-stage rehabilitation of the severely atrophic maxillary ridge using customized porous titanium or polyether ether ketone (PEEK) sub-periosteal implants. Ten patients with a severely atrophic anterior maxillary alveolar ridge were divided randomly into two groups (five patients in each) to receive customized sub-periosteal implants fabricated via CAD/CAM technology: group 1, porous titanium implants; group 2, PEEK implants. Prosthetic loading with fixed acrylic bridges was performed 1 month postoperative. The implants were followed-up for 12 months and evaluated for the presence of any sign of radiographic bone resorption, mobility, infection, prosthetic fracture, or implant exposure. The immediate postoperative period was uneventful except for one case complicated by wound dehiscence in group 1. At 12 months, all implants were functionally stable and the patients were comfortable with the prostheses. No signs of radiographic bone resorption, mobility, infection, or prosthetic fracture were observed. Within the limitations of this study, the application of customized porous titanium and PEEK sub-periosteal implants produced through CAD/CAM technology appears to be an acceptable method for single-stage prosthetic rehabilitation of the severely atrophic edentulous anterior maxilla. This study was awarded the best case study at the academy of osseintegration annual meeting 2017, Orlando, Florida. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Esposito, Marco; Cardaropoli, Daniele; Gobbato, Luca; Scutellà, Fabio; Fabianelli, Andrea; Mascellani, Saverio; Delli Ficorelli, Gianluca; Mazzocco, Fabio; Sbricoli, Luca; Trullenque-Eriksson, Anna
To evaluate whether there are aesthetic and clinical benefits to using a newly designed abutment (Curvomax), over a conventional control abutment (GingiHue). A total of 49 patients, who required at least two implants, had two sites randomised according to a split-mouth design to receive one abutment of each type at seven different centres. The time of loading (immediate, early or delayed) and of prosthesis (provisional crowns of fixed prosthesis) was decided by the clinicians, but they had to restore both implants in a similar way. Provisional prostheses were replaced by definitive ones 3 months after initial loading, when the follow-up for the initial part of this study was completed. Outcome measures were: prosthesis failures, implant failures, complications, pink esthetic score (PES), peri-implant marginal bone level changes, and patient preference. In total, 49 Curvomax and 49 GingiHue abutments were delivered. Two patients dropped out. No implant failure, prosthesis failure or complication was reported. There were no differences at 3 months post-loading for PES (difference = -0.15, 95% CI -0.55 to 0.25; P (paired t test) = 0.443) and marginal bone level changes (difference = -0.02 mm, 95% CI -0.20 to 0.16; P (paired t test) = 0.817). The majority of the patients (30) had no preference regarding the two abutment designs; 11 patients preferred the Curvomax, while five patients preferred the GingiHue abutments (P (McNemar test) = 0.210). The preliminary results of the comparison between two different abutment designs did not disclose any statistically significant differences between the evaluated abutments. However the large number of missing radiographs and clinical pictures casts doubt on the reliability of the results. Longer follow-ups of wider patient populations are needed to better understand whether there is an effective advantage with one of the two abutment designs. Conflict of interest statement: This research project was originally partially funded by Biomax (Andover, MA, USA), the manufacturer of the Curvomax abutments evaluated in this investigation. Biomax, under pressure from some investigators, asked to modify the original agreed protocol. In a following phase, Zimmer-Biomet (Palm Beach Gardens, Florida, USA), the manufacturer of the implants and the GingiHue abutments, took over the funding of this project. Data belonged to the authors and the sponsors did not interfere with the publication of results.
Tomaszewski, P K; Verdonschot, N; Bulstra, S K; Rietman, J S; Verkerke, G J
2012-11-01
Direct attachment of an upper leg prosthesis to the skeletal system by a percutaneous implant is an alternative solution to the traditional socket fixation. In this study, we investigated long-term periprosthetic bone changes around two types of fixation implants using two different initial conditions, namely immediate post-amputation implantation and the conventional implantation after considerable time of socket prosthesis use. We questioned the difference in bone modeling response the implants provoked and if it could lead to premature bone fracture. Generic CT-based finite element models of an intact femoral bone and amputated bone implanted with models of two existing direct-fixation implants, the OPRA system (Integrum AB) and the ISP Endo/Exo prosthesis (ESKA Implants AG) were created for this study. Adaptive bone-remodeling simulations used the heel-strike and toe-off loads from a normal walking cycle. The bone loss caused by prolonged use of socket prosthesis had more severe effects on the ultimate bone quality than adaptation induced by the direct-fixation implants. Both implants showed considerable bone remodeling; the titanium screw implant (OPRA system) provoked more bone loss than the porous coated CoCrMo stem (ISP implant). The chance of the peri-prosthetic bone fracture remained higher for the post-socket case as compared to the direct amputation cases. In conclusion, both direct-fixation implants lead to considerable bone loss and bone loss is more severe after a prolonged period of post-socket use. Hence, from a biomechanical perspective it is better to limit the post-socket time and to re-design direct fixation devices to reduce bone loss and the probability of peri-prosthetic bone fractures. Copyright © 2012 Elsevier Ltd. All rights reserved.
de Waal, Yvonne C M; Raghoebar, Gerry M; Huddleston Slater, James J R; Meijer, Henny J A; Winkel, Edwin G; van Winkelhoff, Arie Jan
2013-02-01
The objective of this randomized, double-blind, placebo-controlled trial was to study the effect of implant surface decontamination with chlorhexidine (CHX)/cetylpyridinium chloride (CPC) on microbiological and clinical parameters. Thirty patients (79 implants) with peri-implantitis were treated with resective surgical treatment consisting of apically re-positioned flap, bone re-contouring and surface debridement and decontamination. Patients were randomly allocated to decontamination with 0.12% CHX + 0.05% CPC (test-group) or a placebo-solution (without CHX/CPC, placebo-group). Microbiological parameters were recorded during surgery; clinical and radiographical parameters were recorded before (pre-) treatment (baseline), and at 3, 6 and 12 months after treatment. Nine implants in two patients in the placebo-group were lost due to severe persisting peri-implantitis. Both decontamination procedures resulted in significant reductions of bacterial load on the implant surface, but the test-group showed a significantly greater reduction than the placebo-group (log 4.21 ± 1.89 versus log 2.77 ± 2.12, p = 0.006). Multilevel analysis showed no differences between both groups in the effect of the intervention on bleeding, suppuration, probing pocket depth and radiographical bone loss over time. Implant surface decontamination with 0.12% CHX + 0.05% CPC in resective surgical treatment of peri-implantitis leads to a greater immediate suppression of anaerobic bacteria on the implant surface than a placebo-solution, but does not lead to superior clinical results. The long-term microbiological effect remains unknown. © 2012 John Wiley & Sons A/S.
Shabiby, Mufida M; Karanja, Joseph G; Odawa, Francis; Kosgei, Rose; Kibore, Minnie W; Kiarie, James N; Kinuthia, John
2015-08-19
Family planning is a cost effective strategy for prevention of mother to child transmission of HIV and reduction of maternal/infant morbidity and mortality. Contraceptive implants are a safe, effective, long term and reversible family planning method whose use remains low in Kenya. We therefore set out to determine and compare the uptake, and factors influencing uptake of immediate postpartum contraceptive implants among HIV infected and uninfected women at two hospitals in Kenya. This cross sectional study targeted postpartum mothers at two Kenyan district hospitals (one urban and one rural). All participants received general family planning and method specific (Implant) counseling followed by immediate insertion of contraceptive implants to those who consented. The data was analyzed by descriptive analysis, T-test, Chi square tests and logistic regression. One hundred eighty-five participants were enrolled (91 HIV positive and 94 HIV negative) with a mean age of 26 years. HIV positive mothers were significantly older (27.5 years) than their HIV negative counterparts (24.5 years), P = 0.001. The two groups were comparable in education, employment, marital status and religious affiliation. Overall, the uptake of contraceptive implants in the immediate postpartum period was 50.3% and higher among HIV negative than HIV positive participants (57% vs. 43%, P = 0.046). Multivariate analysis revealed that a negative HIV status (P = 0.017) and prior knowledge of contraceptive implants (P = 0.001) were independently associated with increased uptake of contraceptive implants. There was a high uptake of immediate postpartum contraceptive implants among both HIV infected and un-infected women; efforts therefore need to be made in promoting this method of family planning in Kenya and providing this method to women in the immediate postpartum period so as to utilize this critical opportunity to increase uptake and reduce the high unmet need for family planning.
Immediate Implant-based Prepectoral Breast Reconstruction Using a Vertical Incision
Lind, Jeffrey G.; Hopkins, Elizabeth G.
2015-01-01
Background: Ideally, breast reconstruction is performed at the time of mastectomy in a single stage with minimal scarring. However, postoperative complications with direct-to-implant subpectoral reconstruction remain significant. These include asymmetry, flap necrosis, animation deformity, and discomfort. We report on a series of patients who have undergone immediate single-stage prepectoral, implant-based breast reconstruction with a smooth, adjustable saline implant covered with mesh/acellular dermal matrix for support using a vertical mastectomy incision. This technique, when combined with an adjustable implant, addresses the complications related to subpectoral implant placement of traditional expanders. Our follow-up time, 4.6 years (55 months), shows a low risk of implant loss and elimination of animation deformity while also providing patients with a safe and aesthetically pleasing result. Methods: All patients who underwent immediate implant-based prepectoral breast reconstruction using a vertical mastectomy incision as a single-staged procedure were included. Charts were reviewed retrospectively. Adjustable smooth round saline implants and mesh/acellular dermal matrix were used for fixation in all cases. Results: Thirty-one patients (62 breasts) underwent single-staged implant-based prepectoral breast reconstruction using a vertical mastectomy incision. Postoperative complications occurred in 9 patients, 6 of which were resolved with postoperative intervention while only 2 cases resulted in implant loss. Conclusions: There can be significant morbidity associated with traditional subpectoral implant-based breast reconstruction. As an alternative, the results of this study show that an immediate single-stage prepectoral breast reconstruction with a smooth saline adjustable implant, using a vertical incision, in conjunction with mesh/matrix support can be performed with excellent aesthetic outcomes and minimal complications. PMID:26180713
Pozzi, Alessandro; Arcuri, Lorenzo; Moy, Peter K
2018-03-01
The growing interest in minimally invasive implant placement and delivery of a prefabricated provisional prosthesis immediately, thus minimizing "time to teeth," has led to the development of numerous 3-dimensional (3D) planning software programs. Given the enhancements associated with fully digital workflows, such as better 3D soft-tissue visualization and virtual tooth rendering, computer-guided implant surgery and immediate function has become an effective and reliable procedure. This article describes how modern implant planning software programs provide a comprehensive digital platform that enables efficient interplay between the surgical and restorative aspects of implant treatment. These new technologies that streamline the overall digital workflow allow transformation of the digital wax-up into a personalized, CAD/CAM-milled provisional restoration. Thus, collaborative digital workflows provide a novel approach for time-efficient delivery of a customized, screw-retained provisional restoration on the day of implant surgery, resulting in improved predictability for immediate function in the partially edentate patient.
[A PhD completed 1. Immediate dental implant placement in the aesthetic zone].
Slagter, K W
2016-05-01
When aesthetics play a role in an extraction, the tendency is to place an implant in the extraction socket immediately, preferably in combination with a temporary crown. This tendency is probably related to evolving social factors: demanding patients who want an instant and attactive result. In 2 randomised clinical trials (total 80 patients) the results of clinical treatment involving immediate implants in the aesthetic zone are investigated. Depending on the size of the bone defect (< 5 or ≥ 5 mm) the number of surgical interventions was reduced from 2 to 1 or from 3 to 2. The treatment result was measured by the following outcome variables: survival rate, changes in hard and soft -peri-implant tissues, aesthetic indecees and patient-satisfaction. The most important conclusion is that immediate placements of implants in the aesthetic zone, results in -outstanding short-term (1-year) results with respect to the outcome variables. If this also leads to good long-term results has yet to be investigated.
Yoda, Nobuhiro; Ogawa, Toru; Gunji, Yoshinori; Vanegas, Juan R; Kawata, Tetsuo; Sasaki, Keiichi
2016-08-01
The mechanisms by which the loads exerted on implants that support prostheses are modulated during mastication remain unclear. The purpose of this study was to evaluate the effects of food texture on 3-dimensional loads measured at a single implant using a piezoelectric transducer. Two subjects participated in this study. The transducer and the experimental superstructure, which had been adjusted to the subject's occlusal scheme, were attached to the implant with a titanium screw. The foods tested were chewing gum and peanuts. The mean maximum load on the implant in each chewing cycle was significantly higher during peanut chewing than during gum chewing. The direction of maximum load was significantly more widely dispersed during peanut chewing than during gum chewing. The range of changes in load direction during the force-increasing phase of each chewing cycle was significantly wider during peanut chewing than during gum chewing. The load on the implant was affected by food texture in both subjects. This measurement method can be useful to investigate the mechanisms of load modulation on implants during mastication.
Amato, Francesco; Polara, Giorgio
The aim of this study was to investigate the survival rate of implants immediately placed in fresh extraction sockets of molars in the maxilla and mandible with a single-stage procedure. A total of 102 patients were treated, and 107 implants (53 in the maxilla and 54 in the mandible) were placed in a fresh molar extraction socket and connected to a healing abutment. After a mean follow-up of 3 years (range: 1 to 6 years) 1 implant failed, for a cumulative success rate of 99.06% (98.11% for the mandible and 100% for the maxilla). The results of this study support placement of an implant immediately after the extraction of a molar, applying a single-stage procedure.
Sexson, Matthew G.; Mulcahy, Daniel M.; Spriggs, Maria; Myers, Gwen E.
2014-01-01
Surgically implanted transmitters are a common method for tracking animal movements. Immediately following surgical implantation, animals pass through a critical recovery phase when behaviors may deviate from normal and the likelihood of individual survival may be reduced. Therefore, data collected during this period may be censored to minimize bias introduced by surgery-related behaviors or mortality. However, immediate post-release mortalities negate a sampling effort and reduce the amount of data potentially collected after the censoring period. Wildlife biologists should employ methods to support an animal’s survival through this period, but factors contributing to immediate post-release survival have not been formally assessed. We evaluated factors that potentially influenced the immediate post-release survival of 56 spectacled eiders (Somateria fischeri) marked with coelomically implanted satellite transmitters with percutaneous antennae in northern Alaska in 2010 and 2011. We modeled survival through the first 14 days following release and assessed the relative importance and effect of 15 covariates hypothesized to influence survival during this immediate post-release period. Estimated daily survival rate increased over the duration of the immediate post-release period; the probability of mortality was greatest within the first 5 days following release. Our top-ranking model included the effect of 2 blood analytes, pH and hematocrit, measured prior to surgical implantation of a transmitter. We found a positive response to pH; eiders exhibiting acidemia (low pH) prior to surgery were less likely to survive the immediate post-release period. We found a curvilinear response to hematocrit; eiders exhibiting extremely low or high pre-surgery hematocrit were also less likely to survive the immediate post-release period. In the interest of maximizing the survival of marked birds following release, hematological data obtained prior to surgical implantation of telemetry equipment may be useful when screening for optimal surgical candidates or informing appropriate response to mitigate potentially deleterious disorders such as acidemia.
Van Weehaeghe, Manú; De Bruyn, Hugo; Vandeweghe, Stefan
2017-12-01
An angulation of the implant connection could overcome the problems related to angulated abutments. This study compares conventional implants with angulated abutment to tilted implants with an angulated connection. Twenty patients were treated in the edentulous mandible. In the posterior jaw locations, one conventional tilted implant with angulated abutment and one angulated implant without abutment were placed. In the anterior jaw, two conventional implants were placed, one with and one without abutment. Implants were immediately loaded and 3 months later, the final bridge (PFM or monolithic zirconia) was placed. After a follow-up of 48 months, 17 patients were available for clinical examination. The mean overall marginal bone loss (MBL) was 1.26 mm. No significant differences in implant survival, MBL, periodontal indices, patients' satisfaction, or complications was found between implants restored on abutment or implant level, between the posteriorly located angulated implant nor angulated abutment, and between both anterior implants with or without abutment. The posterior implants demonstrated less MBL compared to the anterior implants (P < .001). There was no significant difference in MBL between the implants restored with zirconia or PFM bridges (P = .294). Overall mean pocket depth was 2.83 mm. More plaque was found in the PFM group compared to the full-zirconia group, at the bridge (P = .042) and the implants (P = .029). There was no difference between both materials in pocket depth (P = .635) or bleeding (P = .821). One zirconia bridge fractured, two angulated abutment were replaced and four loose bridge screws connected to the angulated abutments had to be tightened. Patients were overall satisfied (4.74/5). An implant with angulated connection may results in a stronger connection but does not affect the marginal bone loss. No difference in MBL was seen between implants restored on abutment or implant level. Zirconia seems to reduce the amount of plaque. © 2017 Wiley Periodicals, Inc.
Ghoveizi, Rahab; Alikhasi, Marzieh; Siadat, Mohammad-Reza; Siadat, Hakimeh; Sorouri, Majid
2013-01-01
Objective: Crestal bone loss is a biological complication in implant dentistry. The aim of this study was to compare the effect of progressive and conventional loading on crestal bone height and bone density around single osseointegrated implants in the posterior maxilla by a longitudinal radiographic assessment technique. Materials and Methods: Twenty micro thread implants were placed in 10 patients (two implants per patient). One of the two implants in each patient was assigned to progressive and the other to conventional loading groups. Eight weeks after surgery, conventional implants were restored with a metal ceramic crown and the progressive group underwent a progressive loading protocol. The progressive loading group took different temporary acrylic crowns at 2, 4 and 6 months. After eight months, acrylic crowns were replaced with a metal ceramic crown. Computer radiography of both progressive and conventional implants was taken at 2, 4, 6, and 12 months. Image analysis was performed to measure the height of crestal bone loss and bone density. Results: The mean values of crestal bone loss at month 12 were 0.11 (0.19) mm for progressively and 0.36 (0.36) mm for conventionally loaded implants, with a statistically significant difference (P < 0.05) using Wilcoxon sign rank. Progressively loaded group showed a trend for higher bone density gain compared to the conventionally loaded group, but when tested with repeated measure ANOVA, the differences were not statistically significant (P > 0.05). Conclusion: The progressive group showed less crestal bone loss in single osseointegrated implant than the conventional group. Bone density around progressively loaded implants showed increase in crestal, middle and apical areas. PMID:23724215
Jörn, Daniela; Kohorst, Philipp; Besdo, Silke; Borchers, Lothar; Stiesch, Meike
2016-01-01
Since bacterial leakage along the implant-abutment interface may be responsible for peri-implant infections, a realistic estimation of the interface gap width during function is important for risk assessment. The purpose of this study was to compare two methods for investigating microgap formation in a loaded dental implant, namely, microcomputed tomography (micro-CT) and three-dimensional (3D) nonlinear finite element analysis (FEA); additionally, stresses to be expected during loading were also evaluated by FEA. An implant-abutment complex was inspected for microgaps between the abutment and implant in a micro-CT scanner under an oblique load of 200 N. A numerical model of the situation was constructed; boundary conditions and external load were defined according to the experiment. The model was refined stepwise until its load-displacement behavior corresponded sufficiently to data from previous load experiments. FEA of the final, validated model was used to determine microgap widths. These were compared with the widths as measured in micro-CT inspection. Finally, stress distributions were evaluated in selected regions. No microgaps wider than 13 μm could be detected by micro-CT for the loaded implant. FEA revealed gap widths up to 10 μm between the implant and abutment at the side of load application. Furthermore, FEA predicted plastic deformation in a limited area at the implant collar. FEA proved to be an adequate method for studying microgap formation in dental implant-abutment complexes. FEA is not limited in gap width resolution as are radiologic techniques and can also provide insight into stress distributions within the loaded complex.
Gluckman, Howard; Salama, Maurice; Du Toit, Jonathan
2018-04-01
Tooth loss results in an inevitable alveolar ridge reduction. This has established a cautionary approach to extract, wait, augment, and insert the implant, in lieu of immediate placement. However, saving the tooth or part of it whenever possible is more conservative and supports the vital periodontal tissue buccofacial to an implant. The purpose of this cases series was to report on implant survival using this technique in a large cohort of patients at mid-term follow-up. A private practice patient database was searched for all patients having received socket-shield treatment in conjunction with immediate implant placement. Of the results returned, 128 met the inclusion criteria of ≥12 months from date of restoration, or failing prior to definitive restoration. These patients were recalled for evaluation of the restored implants up to 4 years post-treatment. Seventy immediate implants with socket-shields were placed in female patients and 58 in males, age range 24-71 (mean 39 years). The distribution of sites treated were: maxillary incisors (64%), premolars (22%), canines (14%); maxilla (89.9%), mandible (10.1%). 123/128 implants osseointegrated and survived 1-4 years following restoration (survival rate 96.1%). A combined complication rate of 25/128 implants occurred (19.5%). Five implants failed to osseointegrate and were removed. The remaining 20 complications were all managed or observed without management, with implants surviving at mid-term follow-up. Notwithstanding technique sensitivity and the need for randomized control studies, this case series demonstrates that the socket-shield performs competitively when compared to implant survival rates in both conventional immediate and delayed implant placement. © 2017 Wiley Periodicals, Inc.
Slagter, Kirsten W; Meijer, Henny J A; Bakker, Nicolaas A; Vissink, Arjan; Raghoebar, Gerry M
2016-06-01
This study aims to assess, with regard to marginal bone level (MBL), whether the outcome of immediate implant placement in bony defects in the esthetic zone was non-inferior to delayed implant placement after 1 year. Forty patients with a failing tooth in the esthetic zone and a labial bony defect of ≥5 mm after removal of a tooth were randomly assigned for immediate (n = 20) or delayed (n = 20) implant placement. Second-stage surgery and provisionalization occurred after 3 months of healing. Follow-up was at 1 month and 1 year after definitive crown placement. The study was powered to detect a difference in MBL of >0.9 mm. Buccal bone thickness, soft tissue peri-implant parameters, esthetic indices, and patient satisfaction were also assessed. One year after definitive crown placement, MBL loss was 0.56 ± 0.39 mm mesially and 0.74 ± 0.51 mm distally for the immediate placement group and 0.51 ± 0.43 mesially and 0.54 ± 0.45 distally mm for the delayed placement group, respectively (not significant). Regarding differences in means, non-inferiority was observed after 1 year (difference in mean for immediate versus delayed: mesially 0.04 mm [95% confidence interval (CI) = -0.22 to 0.30 mm, P = 0.40]; distally 0.21 mm [95% CI = -0.10 to 0.51 mm, P = 0.58]). No significant differences in the other outcome variables were observed. Immediate implant placement with delayed provisionalization was non-inferior to delayed implant placement with delayed provisionalization in labial bony defects of ≥5 mm regarding change in MBL. Although not powered for other outcome variables, no clinically relevant differences were observed in these variables.
Alharbi, Hend M; Babay, Nadir; Alzoman, Hamad; Basudan, Sumaya; Anil, Sukumaran; Jansen, John A
2015-09-01
Minimizing crestal bone loss following immediate implant placement is considered the most challenging aspect in implant therapy. Implant surface topography and chemical modifications have been shown to influence the success of Osseointegration. The Straumann Bone Level implant, featuring SLActive surface, has been introduced with the aim of enhancing bone apposition. Similarly, the OsseoSpeed implants from Astra Tech claim to have an enhanced osseointegration. Because of the specific features in the implant design, both companies claim that crestal resorption is minimal with these implants. To evaluate the osseointegration and crestal bone level following immediate placement of Straumann Bone Level implant and OsseoSpeed implants in fresh extraction sockets in Beagle dogs. The distal roots of the second, third and fourth premolars were extracted in both sides of the mandible. The distal roots were removed using a dental elevator. A total of 60 fixtures were installed in 10 Beagle dogs. Two types of implants were used: Straumann Bone-Level implants, which were 8 × 3.3 mm in size, and Astra Tech OsseoSpeed 3.5 S MicroThread implants, which were 8 × 3.5 mm in size. The histomorphometrical evaluation was performed at the end of 4- and 12-week healing. The implant-bone contact and bone volume percentage were assessed. The bone-to-implant contact (BIC) and the bone volume did not show any significant changes for both types of implants. The OsseoSpeed™ implants showed 67.4% and 65.3% BIC, respectively, at 4 and 12 weeks compared with 71.7 and 73.1 for the Straumann Bone-Level implants. The bone volume around both types of implants did not differ significantly at both time periods. The crestal bone resorption was observed for both types of implants. The first BIC at buccal side and lingual side of the implants also did not differ significantly for both implant systems. This study showed that Straumann Bone Level and OsseoSpeed implants induced similar bone response after immediate implantation at 4 and 12 weeks. The immediate implant placement resulted in peri-implant crestal bone-level changes for both types of implants. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Hattingh, André C; De Bruyn, Hugo; Ackermann, Andrew; Vandeweghe, Stefan
Immediate implant placement is performed less frequently in molar extraction sockets than in single root sockets. This is mainly due to the tripodal anatomical configuration of molar roots, which is perceived as complex and therefore unsuitable. The mechanical burden of molar sites, combined with much larger socket dimensions, make it amenable to the use of ultrawide-diameter dental implants. This article describes a practical, sequenced technique that can be used predictably for immediate implant placement in maxillary and mandibular first molar sockets, using a dry skull model for clarification. This detailed description is based on the experience of more than 580 clinical cases over a 10-year period.
Accelerated and enhanced bone formation on novel simvastatin-loaded porous titanium oxide surfaces.
Nyan, Myat; Hao, Jia; Miyahara, Takayuki; Noritake, Kanako; Rodriguez, Reena; Kasugai, Shohei
2014-10-01
With increasing application of dental implants in poor-quality bones, the need for implant surfaces ensuring accelerated osseointegration and enhanced peri-implant bone regeneration is increased. A study was performed to evaluate the osseointegration and bone formation on novel simvastatin-loaded porous titanium oxide surface. Titanium screws were treated by micro-arc oxidation to form porous oxide surface and 25 or 50 μg of simvastatin was loaded. The nontreated control, micro-arc oxidized, and simvastatin-loaded titanium screws were surgically implanted into the proximal tibia of 16-week-old male Wistar rats (n = 36). Peri-implant bone volume, bone-implant contact, and mineral apposition rates were measured at 2 and 4 weeks. Data were analyzed by one-way analysis of variance followed by Tukey's post hoc test. New bone was formed directly on the implant surface in the bone marrow cavity in simvastatin-loaded groups since 2 weeks. Bone-implant contact values were significantly higher in simvastatin-loaded groups than control and micro-arc oxidized groups at both time points (p < .05). Peri-implant bone volume and mineral apposition rate of simvastatin-loaded groups were significantly higher than control and micro-arc oxidized groups at 2 weeks (p < .05). These data suggested that simvastatin-loaded porous titanium oxide surface provides faster osseointegration and peri-implant bone formation and it would be potentially applicable in poor-quality bones. © 2013 Wiley Periodicals, Inc.
Antetomaso, Jordan; Kumar, Satish
2018-03-01
Immediate implant placement into fresh extraction sockets versus delayed implants into healed sockets: a systematic review and meta-analysis. Mello CC, Lemos CAA, Verri FR, Dos Santos DM, Goiato MC, Pellizzer EP. Int J Oral Maxillofac Surg 2017; 46(9):1162-77. None TYPE OF STUDY/DESIGN: Systematic review with meta-analysis of data. Copyright © 2017 Elsevier Inc. All rights reserved.
Immediate implants placed into infected sockets: a case report with 3-year follow-up.
Naves, Marina de Melo; Horbylon, Bruna Zacharias; Gomes, Camila de Freitas; Menezes, Helder Henrique Machado de; Bataglion, César; Magalhães, Denildo de
2009-01-01
The esthetics and functional integrity of the periodontal tissue may be compromised by dental loss. Immediate implants became a viable option to maintain the periodontal architecture because of their anatomic compatibility with the dental socket and the possibility of eliminating local contamination. This article describes the procedure of immediate implant placement in the anterior maxilla replacing teeth with chronic periapical lesions, which were condemned due to endodontic lesions persisting after failed endodontic treatment and endodontic surgery, and discusses the relationship between the procedure and periapical lesions. Surgical removal of hopeless teeth 11, 12 and 21 was performed conservatively in such a way to preserve the anatomy and gingival esthetics. A second surgical access was gained at the apical level, allowing the debridement of the surgical chamber for elimination of the periapical lesion, visual orientation for setting of the implants and filling of the surgical chamber with xenogenous bovine bone graft. After this procedure, the bone chamber was covered with an absorbent membrane and the healing screws were positioned on the implants. Later, a provisional partial removable denture was installed and the implants were inserted after 6 months. After 3 years of rehabilitation, the implants present satisfactory functional and esthetic conditions, suggesting that immediate implant placement combined with guided bone regeneration may be indicated for replacing teeth lost due to chronic periapical lesions with endodontic failure history in the anterior maxilla.
Arafa, Khalid A.
2016-01-01
Objectives: To examine the effects on bone tissues of immediate implant-supported mandibular overdentures with cusped or cuspless teeth. Methods: A randomized controlled trial was conducted at the Dental Clinic, Faculty of Dentistry, Al-Azhar University, Assiut Branch, Egypt, over a 12-month period from September 2013 to September 2014. Twenty patients were treated with immediate implant-supported overdentures: one group received overdentures with cusped teeth, and the other group received overdentures with cuspless teeth. The rate of implant success was assessed clinically and radiographically at 3, 6, 9, and 12 months. The data were collected by a questionnaire, an observation checklist, and radiography. The data were then analyzed using computerized methods. Results: Overdentures with cusped teeth showed a significant improvement in the clinical criteria, including the absence of clinical implant mobility, pain, and bone resorption, while the clinical criteria for the absence of peri-implant radiolucency were insignificantly different between the 2 groups (p>0.05). There were no significant differences in the clinical evaluations for bone levels at the time of insertion or 3 months after insertions, while significant differences were found at 6, 9, and 12 months after insertion. Conclusion: Overdentures with cusped teeth supported by immediate implants were found superior regarding many clinical criteria than those cuspless counterparts. PMID:26739979
Arafa, Khalid A
2016-01-01
To examine the effects on bone tissues of immediate implant-supported mandibular overdentures with cusped or cuspless teeth. A randomized controlled trial was conducted at the Dental Clinic, Faculty of Dentistry, Al-Azhar University, Assiut Branch, Egypt, over a 12-month period from September 2013 to September 2014. Twenty patients were treated with immediate implant-supported overdentures: one group received overdentures with cusped teeth, and the other group received overdentures with cuspless teeth. The rate of implant success was assessed clinically and radiographically at 3, 6, 9, and 12 months. The data were collected by a questionnaire, an observation checklist, and radiography. The data were then analyzed using computerized methods. Overdentures with cusped teeth showed a significant improvement in the clinical criteria, including the absence of clinical implant mobility, pain, and bone resorption, while the clinical criteria for the absence of peri-implant radiolucency were insignificantly different between the 2 groups (p more than 0.05). There were no significant differences in the clinical evaluations for bone levels at the time of insertion or 3 months after insertions, while significant differences were found at 6, 9, and 12 months after insertion. Overdentures with cusped teeth supported by immediate implants were found superior regarding many clinical criteria than those cuspless counterparts.
Outcomes of Dental Implant Therapy in Patients With Down Syndrome: A Systematic Review.
Najeeb, Shariq; Khurshid, Zohaib; Siddiqui, Fahad; Zohaib, Sana; Zafar, Muhammad Sohail
2017-12-01
Patients with Down syndrome (DS) require an earlier and more frequent tooth replacement than rest of the population. The objective of this systematic review is to critically analyze and summarize studies to ascertain the outcomes and survival of dental implants placed in jaws of DS patients. Using the key words "dental implants," "Down syndrome," and "prosthodontics," an electronic search was conducted via PubMed/MEDLINE, ISI Web of Science, Google Scholar, Embase, and Central Register of Controlled Trials (CENTRAL) databases by 2 authors, S.N. and Z.K., independently. Retrieved studies were screened against the predefined exclusion and inclusion criteria. To estimate the risk of bias, quality assessment of included studies was carried using the 'Case Reports (CARE) guidelines'. Primary search resulted in 156 studies. Eight studies met the inclusion criteria and reporting a total of 81 dental implants placed in 36 DS patients. The type of implant loading ranged from immediate to a delay of 1 year after placement of the implant. Implant diameter ranged from 3.3 to 4.5 mm, and height ranged from 8.5 to 18 mm. The follow-up ranged from 1 to 6 years. Of 81 implants placed, 21 implants (26%) were reported as failed. Patients with DS have a higher risk of implant failure. However, the reason for the failure is not very well understood. Although case reports and case series suggest that implant survival is diminished in DS patients, large-scale randomized controlled trials are required to determine the exact mechanism associated with risks of implant failure. Copyright © 2017 Elsevier Inc. All rights reserved.
Trisi, Paolo; Berardini, Marco; Falco, Antonello; Podaliri Vulpiani, Michele
2016-11-01
The osseointegration process replaces the surgically damaged bone with newly formed bone in contact to the implant surface. This involves some loss of primary stability, which will continue until new bone is formed providing a new stability, known as "secondary stability." A direct measurement of secondary implant stability appears fundamental to determine the period and modalities for implant loading. The aim of this study was to validate the measurement of the implant micromotion to test secondary implant stability. Twenty-four 3.8 × 11.5 mm implants (Dynamix, Cortex, Shlomi, Israel) were inserted in sheep iliac crests. The animals were sacrificed after 2 months, and the freshly retrieved bone blocks were immediately fixed on a customized device to calculate the value of actual micromotion (VAM) according to a previously described technique. Implant stability quotient (ISQ) values, reverse torque value (RTV), %bone-to-implant contact (%BIC), bone volume percentage (%BV) and crestal bone loss (CBL) were also calculated for each implant. Statistical correlations between VAM and the other parameters were calculated. Data correlation analysis between the examined parameters showed that VAM significantly correlates (P < 0.05) to RTV, %BIC, ISQ and CBL. As VAM showed to be statistical correlated to the other parameters of osseointegration, it may be used to clinically check the amount of implant osseointegration, secondary stability and CBL. Future studies are needed to confirm these results moreover. An instrument to measure VAM in the oral cavity still needs to be developed. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Mello, C C; Lemos, C A A; Verri, F R; Dos Santos, D M; Goiato, M C; Pellizzer, E P
2017-09-01
The aim of this systematic review and meta-analysis was to compare the survival rate of the implants and the peri-implant tissue changes associated with implants inserted in fresh extraction sockets and those inserted in healed sockets. This review has been registered at PROSPERO under the number CRD42016043309. A systematic search was conducted by two reviewers independently in the databases PubMed/MEDLINE, Embase, and the Cochrane Library using different search terms; articles published until November 2016 were searched for. The searches identified 30 eligible studies. A total of 3,049 implants were installed in a total of 1,435 patients with a mean age of 46.68 years and a minimum of 6 months of follow-up. The survival rate of delayed implants (98.38%) was significantly greater than immediate implants (95.21%) (p=.001). For the marginal bone loss (p=.32), implant stability quotients values (p=.44), and pocket probing depth (p=.94) there was no significant difference between the analysed groups. The immediate implants placed in fresh sockets should be performed with caution because of the significantly lower survival rates than delayed implants inserted in healed sockets. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Lee, Jungwon; Park, Dueun; Koo, Ki-Tae; Seol, Yang-Jo; Lee, Yong-Moo
2018-04-03
This review aimed to investigate the feasibility of immediate implant placement in infected extraction sockets. We performed electronic and manual searches up to March 2017 to obtain data from randomized controlled trials (RCTs) and nonrandomized controlled clinical trials (CCTs). Using a fixed-effects model to assess the difference in survival rate (primary outcome), we evaluated the risk difference for immediate implant placement in infected and non-infected sites. We estimated the weighted mean differences (WMDs) of the change in marginal bone loss (MBL), probing depth (PD), modified bleeding index (mBI), marginal gingival level (MGL) and width of keratinized gingiva (WKG) at baseline and latest follow-up. In total, five studies (0 RCT, five CCTs) were included in the systematic review and three studies were included in the meta-analysis. The risk difference for immediate implant placement in an infected extraction socket compared with that in a non-infected socket was -0.02. WMDs for MBL, PD, mBI, MGL and WKG between the two groups were 0.32, 0.12, 0.07, -0.06, 0.20 and 0.51, respectively. No statistical differences were observed between the two groups, except for the change in WKG. Implants can be placed in infected extraction sockets after thorough socket debridement. For aesthetics, WKG should be considered when performing immediate implant placement in infected sites.
Micolini, Carolina; Holness, Frederick Benjamin; Johnson, James A.
2017-01-01
Load transfer through orthopaedic joint implants is poorly understood. The longer-term outcomes of these implants are just starting to be studied, making it imperative to monitor contact loads across the entire joint implant interface to elucidate the force transmission and distribution mechanisms exhibited by these implants in service. This study proposes and demonstrates the design, implementation, and characterization of a 3D-printed smart polymer sensor array using conductive polyaniline (PANI) structures embedded within a polymeric parent phase. The piezoresistive characteristics of PANI were investigated to characterize the sensing behaviour inherent to these embedded pressure sensor arrays, including the experimental determination of the stable response of PANI to continuous loading, stability throughout the course of loading and unloading cycles, and finally sensor repeatability and linearity in response to incremental loading cycles. This specially developed multi-material additive manufacturing process for PANI is shown be an attractive approach for the fabrication of implant components having embedded smart-polymer sensors, which could ultimately be employed for the measurement and analysis of joint loads in orthopaedic implants for in vitro testing. PMID:29186079
Brozović, Juraj; Demoli, Nazif; Farkaš, Nina; Sušić, Mato; Alar, Zeljko; Gabrić Pandurić, Dragana
2014-03-01
The aim of this study was to (i) obtain the force-related interferometric patterns of loaded dental implant-abutment assemblies differing in diameter and brand using digital holographic interferometry (DHI) and (ii) determine the influence of implant diameter on the extent of load-induced implant deformation by quantifying and comparing the obtained interferometric data. Experiments included five implant brands (Ankylos, Astra Tech, blueSKY, MIS and Straumann), each represented by a narrow and a wide diameter implant connected to a corresponding abutment. A quasi-Fourier setup with a 25mW helium-neon laser was used for interferometric measurements in the cervical 5mm of the implants. Holograms were recorded in two conditions per measurement: a 10N preloaded and a measuring-force loaded assembly, resulting with an interferogram. This procedure was repeated throughout the whole process of incremental axial loading, from 20N to 120N. Each measurement series was repeated three times for each assembly, with complete dismantling of the implant-loading device in between. Additional software analyses calculated deformation data. Deformations were presented as mean values±standard deviations. Statistical analysis was performed using linear mixed effects modeling in R's lme4 package. Implants exhibited linear deformation patterns. The wide diameter group had lower mean deformation values than the narrow diameter group. The diameter significantly affected the deformation throughout loading sessions. This study gained in vitro implant performance data, compared the deformations in implant bodies and numerically stated the biomechanical benefits of wider diameter implants. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Stability of smooth and rough mini-implants: clinical and biomechanical evaluation - an in vivostudy
Vilani, Giselle Naback Lemes; Ruellas, Antônio Carlos de Oliveira; Elias, Carlos Nelson; Mattos, Cláudia Trindade
2015-01-01
Objective: To compare in vivo orthodontic mini-implants (MI) of smooth (machined) and rough (acid etched) surfaces, assessing primary and secondary stability. Methods: Thirty-six (36) MI were inserted in the mandibles of six (6) dogs. Each animal received six (6) MI. In the right hemiarch, three (3) MI without surface treatment (smooth) were inserted, whereas in the left hemiarch, another three (3) MI with acid etched surfaces (rough) were inserted. The two distal MI in each hemiarch received an immediate load of 1.0 N for 16 weeks, whereas the MI in the mesial extremity was not subject to loading. Stability was measured by insertion and removal torque, initial and final mobility and by inter mini-implant distance. Results: There was no statistical behavioral difference between smooth and rough MI. High insertion torque and reduced initial mobility were observed in all groups, as well as a reduction in removal torques in comparison with insertion torque. Rough MI presented higher removal torque and lower final mobility in comparison to smooth MI. MI did not remain static, with displacement of rough MI being smaller in comparison with smooth MI, but with no statistical difference. Conclusions: MI primary stability was greater than stability measured at removal. There was no difference in stability between smooth and rough MI when assessing mobility, displacement and insertion as well as removal torques. PMID:26560819
Kolerman, Roni; Nissan, Joseph; Mijiritsky, Eitan; Hamoudi, Nasreen; Mangano, Carlo; Tal, Haim
2016-11-01
Esthetic assessment of immediately restored implants combined with GBR and free connective tissue (CT) graft METHODS: A case-control, retrospective study involving 34 patients treated with maxillary anterior single implants, immediately placed and restored. Clinical and esthetic results were analyzed using standard clinical examination and a comprehensive index, comprising pink esthetic and white esthetic scores (PES/WES). The height of the implant crown and the corresponding height of the contralateral tooth crown were measured to identify mucosal recessions. The distance from the mucosal margin to the implant shoulder (DIM) was measured on the master model. Thirty of 34 implants fulfilled the strict success criteria set for dental implants with regard to osseointegration. Success was defined as implants with bone loss not exceeding 1.5 mm during the first year and loosing not more than 0.2 for each successive year. The other four implants were stable but did not meet the bone loss criteria mentioned above and defined as survived implants. Mean PES/WES was 14.44 ± 2.34 (range: 9-20). Mean PES was 7.12 ± 1.89 (range: 1-10). The highest mean values were achieved for the variable of root convexity/soft tissue color and texture (1.71 ± 0.46) whereas the mesial papilla (1.09 ± 0.62) proved to be the least pleasing. The mean WES was 7.32 ± 1.25 (range: 5-10). The difference between IC and contralateral TC was 0.54 mm. The mean value for the facial DIM was 3.82 ± 0.87 mm. An evaluation of soft and hard tissue augmentation in immediately restored immediate implant procedures was employed to obtain stable hard and soft tissues. The combined GBR and CT graft procedure achieved favorable peri-implant soft tissue condition and esthetic results. However, recession and incomplete papillas were frequently observed. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Siciliano, V Iorio; Salvi, G E; Matarasso, S; Cafiero, C; Blasi, A; Lang, N P
2009-05-01
To assess soft tissues healing at immediate transmucosal implants placed into molar extraction sites with buccal self-contained dehiscences. For this 12-month controlled clinical trial, 15 subjects received immediate transmucosal tapered-effect (TE) implants placed in molar extraction sockets displaying a buccal bone dehiscence (test sites) with a height and a width of > or =3 mm, respectively. Peri-implant marginal defects were treated according to the principles of Guided Bone Regeneration (GBR) by means of deproteinized bovine bone mineral particles in conjunction with a bioresorbable collagen membrane. Fifteen subjects received implants in healed molar sites (control sites) with intact buccal alveolar walls following tooth extraction. In total, 30 TE implants with an endosseous diameter of 4.8 mm and a shoulder diameter of 6.5 mm were used. Flaps were repositioned and sutured, allowing non-submerged, transmucosal soft tissues healing. At the 12-month follow-up, pocket probing depths (PPD) and clinical attachment levels (CAL) were compared between implants placed in the test and the control sites, respectively. All subjects completed the 12-month follow-up period. All implants healed uneventfully, yielding a survival rate of 100%. After 12 months, statistically significantly higher (P<0.05) PPD and CAL values were recorded around implants placed in the test sites compared with those placed in the control sites. The findings of this controlled clinical trial showed that healing following immediate transmucosal implant installation in molar extraction sites with wide and shallow buccal dehiscences yielded less favorable outcomes compared with those of implants placed in healed sites, and resulted in lack of 'complete' osseointegration.
Guarnieri, Renzo; Belleggia, Fabrizio; Grande, Maurizio
2016-02-01
To compare peri-implant marginal bone loss, soft tissue response, and esthetics following single immediate implant treatment (IIT) and delayed implant treatment (DIT) in the esthetic zone of the maxilla in well-selected patients. Adequate bone volume and ideal soft tissue level/contour were considered requirements for implant therapy, with additional prerequisites for IIT of residual alveolar bone wall integrity and a thick gingival biotype. IIT included immediate placement and provisionalization, while DIT included extraction socket preservation followed by implant placement and provisionalization 4 months later. Cortical bone levels and peri-implant mucosal conditions were evaluated at regular intervals. The esthetic outcome was objectively rated after 3 years using the pink esthetic score (PES) and white esthetic score (WES). Twelve patients received an immediate Laser-Lok® implant, and 13 patients received a delayed Laser-Lok® implant. No significant differences were found between the study groups regarding survival rate (100%). The mean bone level from the implant/abutment interface was 0.35 ± 0.18 mm for IIT and 0.42 ± 0.21 mm for DIT after 3 years (p > 0.05). Mesial and distal papillae remained stable over time in DIT. A tendency for regrowth of mesial and distal papillae was found following IIT (p < 0.05). Midfacial soft tissues remained stable over time following DIT and IIT. Within the limitations of this study (e.g., small sample size, short follow-up duration), the results suggest that regarding success rate, hard/soft tissue responses, and esthetics, DIT and IIT with single Laser-Lok® implants in the anterior maxilla are comparable and predictable options for well-selected patients. © 2015 by the American College of Prosthodontists.
Constant strain rate and peri-implant bone modeling: an in vivo longitudinal micro-CT analysis.
De Smet, Els; Jaecques, Siegfried V N; Wevers, Martine; Sloten, Jos Vander; Naert, Ignace E
2013-06-01
Strain, frequency, loading time, and strain rate, among others, determine mechanical parameters in osteogenic loading. We showed a significant osteogenic effect on bone mass (BM) by daily peri-implant loading at 1.600µε.s(-1) after 4 weeks. To study the peri-implant osteogenic effect of frequency and strain in the guinea pig tibia by in vivo longitudinal micro-computed tomography (CT) analysis. One week after implant installation in both hind limb tibiae, one implant was loaded daily for 10' during 4 weeks, while the other served as control. Frequencies (3, 10, and 30Hz) and strains varied alike in the three series to keep the strain rate constant at 1.600µε.s(-1) . In vivo micro-CT scans were taken of both tibiae: 1 week after implantation but before loading (v1) and after 2 (v2) and 4 weeks (v3) of loading as well as postmortem (pm). BM (BM (%) bone-occupied area fraction) was calculated as well as the difference between test and control sides (delta BM) RESULTS: All implants (n=78) were clinically stable at 4 weeks. Significant increase in BM was measured between v1 and v2 (p<.0001) and between v1 and v3 (p<.0001). A significant positive effect of loading on delta BM was observed in the distal peri-implant marrow 500 Region of Interest already 2 weeks after loading (p=.01) and was significantly larger (11%) in series 1 compared with series 2 (p=.006) and 3 (p=.016). Within the constraints of constant loading time and strain rate, the effect of early implant loading on the peri-implant bone is strongly dependent on strain and frequency. This cortical bone model has shown to be most sensitive for high force loading at low frequency. © 2011 Wiley Periodicals, Inc.
Wu, Shiyu; Wu, Xiayi; Shrestha, Rachana; Lin, Jinying; Feng, Zhicai; Liu, Yudong; Shi, Yunlin; Huang, Baoxin; Li, Zhipeng; Liu, Quan; Zhang, Xiaocong; Hu, Mingxuan; Chen, Zhuofan
2018-02-01
To evaluate the 5-year clinical and radiologic outcome of immediate implantation using submerged and nonsubmerged techniques with bone-level implants and internal hexagonal connections and the effects of potential influencing factors. A total of 114 bone-level implants (XiVE S plus) with internal hexagonal connections inserted into 72 patients were included. Patients were followed up for 5 years. A t-test was used to statistically evaluate the marginal bone loss between the submerged and nonsubmerged groups. The cumulative survival rate (CSR) was calculated according to the life table method and illustrated with Kaplan-Meier survival curves. Comparisons of the CSR between healing protocols, guided bone regeneration, implants with different sites, lengths, and diameters were performed using log-rank tests. The 5-year cumulative implant survival rates with submerged and nonsubmerged healing were 94% and 96%, respectively. No statistically significant differences in terms of marginal bone loss, healing protocol, application of guided bone regeneration, implant site, or length were observed. High CSRs and good marginal bone levels were achieved 5 years after immediate implantation of bone-level implants with internal hexagonal connections using both the submerged and nonsubmerged techniques. Factors such as implant length, site, and application of guided bone regeneration did not have an impact on the long-term success of the implants. © 2017 by the American College of Prosthodontists.
Shemtov-Yona, K; Rittel, D
2016-09-01
The fatigue performance of dental implants is usually assessed on the basis of cyclic S/N curves. This neither provides information on the anticipated service performance of the implant, nor does it allow for detailed comparisons between implants unless a thorough statistical analysis is performed, of the kind not currently required by certification standards. The notion of endurance limit is deemed to be of limited applicability, given unavoidable stress concentrations and random load excursions, that all characterize dental implants and their service conditions. We propose a completely different approach, based on random spectrum loading, as long used in aeronautical design. The implant is randomly loaded by a sequence of loads encompassing all load levels it would endure during its service life. This approach provides a quantitative and comparable estimate of its performance in terms of lifetime, based on the very fact that the implant will fracture sooner or later, instead of defining a fatigue endurance limit of limited practical application. Five commercial monolithic Ti-6Al-4V implants were tested under cyclic, and another 5 under spectrum loading conditions, at room temperature and dry air. The failure modes and fracture planes were identical for all implants. The approach is discussed, including its potential applications, for systematic, straightforward and reliable comparisons of various implant designs and environments, without the need for cumbersome statistical analyses. It is believed that spectrum loading can be considered for the generation of new standardization procedures and design applications. Copyright © 2016 Elsevier Ltd. All rights reserved.
Basha, Asim Ghouse; Shantaraj, Ravi; Mogegowda, Shivalinga B
2010-04-01
The purpose of this study was to measure and compare the difference between rate of en-masse retraction with mini-implant and molar anchorage. A comparative study consisting of 14 patients (all females) randomized into 2 groups. Seven in group I (nonimplant) molar was used as anchor for en-masse retraction of anterior teeth (mean age 16 years SD +/- 1.41). In group II (implant), mini-implant was used as anchorage to retract the anterior teeth (mean age 17.36 SD +/- 1.35). In both groups, all first premolars were extracted. After leveling and aligning, surgical steel mini-implant of 1.3 mm in diameter and 8 mm in length were placed between the roots of second premolar and first molar in the maxilla in the implant group. Implants were immediately loaded with 2 N of force. In nonimplant group molar was used as anchorage. The retraction and postretraction lateral cephalograms were taken. Rate of retraction and anchor loss were measured by using pterygoid vertical in maxilla. Four implants became loose during the treatment, which were subsequently replaced. The stability of surgical steel in this study was 71.4%. Student t test were used to analyze the treatment charges in 2 groups. Mean anchor loss in maxilla in nonimplant group. No differences in the mean rate of retraction time were noted in both groups. Mini-implants provided absolute anchorage in patients requiring maximum anterior retraction. No differences in the mean retraction time were noted between 2 groups.
Time Course of Peri-Implant Bone Regeneration around Loaded and Unloaded Implants in a Rat Model
Jariwala, Shailly H.; Wee, Hwabok; Roush, Evan P.; Whitcomb, Tiffany L.; Murter, Christopher; Kozlansky, Gery; Lakhtakia, Akhlesh; Kunselman, Allen R.; Donahue, Henry J.; Armstrong, April D.; Lewis, Gregory S.
2018-01-01
The time-course of cancellous bone regeneration surrounding mechanically loaded implants affects implant fixation, and is relevant to determining optimal rehabilitation protocols following orthopaedic surgeries. We investigated the influence of controlled mechanical loading of titanium-coated polyether-ether ketone (PEEK) implants on osseointegration using time-lapsed, non-invasive, in vivo micro-computed tomography (micro-CT) scans. Implants were inserted into proximal tibial metaphyses of both limbs of eight female Sprague-Dawley rats. External cyclic loading (60 μm or 100 μm displacement, 1 Hz, 60 seconds) was applied every other day for 14 days to one implant in each rat, while implants in contralateral limbs served as the unloaded controls. Hind limbs were imaged with high-resolution micro-CT (12.5 μm voxel size) at 2, 5, 9, and 12 days post-surgery. Trabecular changes over time were detected by 3D image registration allowing for measurements of bone-formation rate (BFR) and bone-resorption rate (BRR). At day 9, mean %BV/TV for loaded and unloaded limbs were 35.5 ± 10.0 % and 37.2 ± 10.0 %, respectively, and demonstrated significant increases in bone volume compared to day 2. BRR increased significantly after day 9. No significant differences between bone volumes, BFR, and BRR were detected due to implant loading. Although not reaching significance (p = 0.16), an average 119 % increase in pull-out strength was measured in the loaded implants. PMID:27381807
Gehrke, Sergio Alexandre; Delgado-Ruiz, Rafael Arcesio; Prados Frutos, Juan Carlos; Prados-Privado, María; Dedavid, Berenice Anina; Granero Marín, Jose Manuel; Calvo Guirado, José Luiz
This study aimed to evaluate the misfit of three different implant-abutment connections before and after cycling load. One hundred twenty dental implants and correspondent prefabricated titanium abutments were used. Three different implant-abutment connections were evaluated: Morse taper (MT group), external hexagon (EH group), and internal hexagon (IH group). Forty implants and 40 abutments were used per group. The parameters for the mechanical evaluation were set as: 360,000 cycles, load of 150 N, and frequency of 4 Hz. Samples were sectioned in their longitudinal and transversal axes, and the misfit of the implant-abutment connection was evaluated by scanning electron microscopy analysis. One-way analyses of variance, Tukey post hoc analyses (α = .05), and t test (P < .05) were used to determine differences between groups. At the longitudinal direction, all the groups showed the presence of microgaps before cycling load; after cycling load, microgaps were reduced in all groups (P > .05). Transversally, only the MT group showed full fitting after cycling load compared with the other groups (EH and IH) (P < .0001). The application of cycling load produces an accommodation of the implant-abutment connection in internal, external, and Morse taper connections. In the longitudinal direction, the accommodation decreases and/or eliminates the gap observed initially (before load). In the horizontal direction, Morse cone implant-abutment connections experience a complete accommodation with the elimination of the gap.
Dynamic fatigue performance of implant-abutment assemblies with different tightening torque values.
Xia, Dandan; Lin, Hong; Yuan, Shenpo; Bai, Wei; Zheng, Gang
2014-01-01
Implant-abutment assemblies are usually subject to long-term cyclic loading. To evaluate the dynamic fatigue performance of implant-abutment assemblies with different tightening torque values, thirty implant-abutment assemblies (Zimmer Dental, Carlsbad, CA, USA) were randomly assigned to three tightening groups (24 Ncm; 30 Ncm; 36 Ncm), each consisted of 10 implants. Five specimens from each group were unscrewed, and their reverse torque values recorded. The remaining specimens were subjected to a load between 30 N~300 N at a loading frequency of 15 Hz for 5 × 10(6) cycles. After fatigue tests, residual reverse torque values were recorded if available. In the 24 Ncm tightening group, all the implants fractured at the first outer thread of the implant after fatigue loading, with fatigue crack propagation at the fractured surface showed by SEM observation. For the 30 Ncm and 36 Ncm tightening groups, a statistical significant difference (p<0.05) between the unloaded and loaded groups was revealed. Compared with the unloaded specimens, the specimens went through fatigue loading had decreased reverse torque values. It was demonstrated that insufficient torque will lead to poor fatigue performance of dental implant-abutment assemblies and abutment screws should be tightened to the torque recommended by the manufacturer. It was also concluded that fatigue loading would lead to preload loss.
Kuroda, Flavia; Urban, Cicero; Zucca-Matthes, Gustavo; de Oliveira, Vilmar Marques; Arana, Gabriel Hubner; Iera, Marco; Rietjens, Mario; Santos, Gabriela; Spagnol, Caroline; de Lima, Rubens Silveira
2016-02-01
Although there are many reports on different techniques in breast reconstruction, there are few data regarding immediate breast reconstruction with definitive form-stable anatomical implants in terms of aesthetics and quality-of-life outcomes. Ninety-four patients underwent mastectomy with immediate breast reconstruction using anatomical implants and contralateral symmetrization. Aesthetic results were evaluated by three different methods: the patient's self-report, the assessment of four independent specialists (two breast surgeons and two plastic surgeons from different institutions), and the BCCT.core software. Quality of life was evaluated by means of the BREAST-Q instrument. Average age ± SD was 52.1 ± 11.6 years. Most of patients had medium size breasts and T1 tumors. Patients had evaluated their aesthetic results better than did software and specialists. There was no significant difference in the comparison between software and specialist's evaluation. Multifactorial analysis showed that age older than 70 years and radiotherapy were significant risk factors for poor aesthetic outcomes after immediate breast reconstruction with implants. Considering quality of life, most of the patients were satisfied with their outcome and psychosocial and sexual well-being. Immediate breast reconstruction with implants and contralateral symmetrization had a positive impact on the quality of life and showed satisfactory outcomes when evaluated by subjective and objective methods.
Chrcanovic, Bruno Ramos; Albrektsson, Tomas; Wennerberg, Ann
2015-01-01
To test the null hypothesis of no difference in the implant failure rates, postoperative infection and marginal bone loss for the insertion of dental implants in fresh extraction sockets compared to the insertion in healed sites, against the alternative hypothesis of a difference. Main search terms used in combination: dental implant, oral implant, resh extraction socket, immediate placement, immediate insertion, immediate implant. An electronic search was undertaken in July/2014, in PubMed, Web of Science, Cochrane Oral Health Group Trials Register plus hand-searching. Eligibility criteria included clinical human studies, either randomized or not. The search strategy resulted in 73 publications, with 8,241 implants inserted in sockets (330 failures, 4.00%), and 19,410 in healed sites (599 failures, 3.09%). It is suggested that the insertion of implants in fresh extraction sockets affects the failure rates (RR 1.58, 95% CI 1.27-1.95, P<0.0001). The difference was not statistically significant when studies evaluating implants inserted in maxillae or in mandibles were pooled, or when the studies using implants to rehabilitate patients with full-arch prostheses were pooled; however, it was significant for the studies that rehabilitated patients with implant-supported single crowns and for the controlled studies. There was no apparent significant effect on the occurrence of postoperative infection or on the magnitude of marginal bone loss. The results should be interpreted with caution due to the potential for biases and to the presence of uncontrolled confounding factors in the included studies, most of them not randomized. The question whether immediate implants are more at risk for failure than implants placed in mature bone has received increasing attention in the last years. As the philosophies of treatment alter over time, a periodic review of the different concepts is necessary to refine techniques and eliminate unnecessary procedures. This would form a basis for optimum treatment. Copyright © 2014 Elsevier Ltd. All rights reserved.
Immediate, non-submerged, root-analogue zirconia implant in single tooth replacement.
Pirker, W; Kocher, A
2008-03-01
This report demonstrates the successful clinical use of a modified root-analogue zirconia implant for immediate single tooth replacement. A right maxillary premolar was removed and a custom-made, root-analogue, roughened zirconia implant with macro-retentions in the interdental space was fabricated and placed into the extraction socket 4 days later. Four months after root implantation a composite crown was cemented. No complications occurred during the healing period. An excellent esthetic and functional result was achieved with the composite crown. No clinically noticeable bone resorption or soft-tissue recession was observed at 26 months follow up. Significant modifications such as macro-retentions seem to indicate that primary stability and excellent osseointegration of immediate root-analogue zirconia implants can be achieved, while preventing unesthetic bone resorption. The macro-retentions must be limited to the interdental space to avoid fracture of the thin buccal cortex. This successful case warrants further clinical research in well controlled trials.
Laser welding and syncristallization techniques comparison: “Ex vivo” study
Meleti, Marco; Vescovi, Paolo; Merigo, Elisabetta; Rocca, Jean-Paul
2013-01-01
Background and aims: Stabilization of implant abutments through electric impulses at high voltage for a very short time (electrowelding) was developed in the Eighties. In 2009, the same procedure was performed through the use of laser (laser welding) The aim of this study is to compare electrowelding and laser welding for intra-oral implant abutments stabilization on “ex vivo models” (pig jaws). Materials and methods: Six bars were welded with two different devices (Nd:YAG laser and Electrowelder) to eighteen titanium implant abutment inserted in three pig jaws. During the welding process, thermal increase was recorded, through the use of k-thermocouples, in the bone close to the implants. The strength of the welded joints was evaluated by a traction test after the removal of the implants. For temperature measurements a descriptive analysis and for traction test “values unpaired t test with Welch's correction” were performed: the significance level was set at P<0.05. Results: Laser welding gives a lower thermal increase than Electrowelding at the bone close to implants (Mean: 1.97 and 5.27); the strength of laser welded joints was higher than that of Electrowelding even if nor statistically significant. (Mean: 184.75 and 168.29) Conclusion: Electrowelding seems to have no advantages, in term of thermal elevation and strength, while laser welding may be employed to connect titanium implants for immediate load without risks of thermal damage at surrounding tissues. PMID:24511205
Jun, Sang Ho; Park, Chang-Joo; Hwang, Suk-Hyun; Lee, Youn Ki; Zhou, Cong; Jang, Hyon-Seok; Ryu, Jae-Jun
2018-12-01
This study was to evaluate the effect of bone graft procedure on the primary stability of implants installed in fresh sockets and assess the vertical alteration of peri-implant bone radiographically. Twenty-three implants were inserted in 18 patients immediately after tooth extraction. The horizontal gap between the implant and bony walls of the extraction socket was grafted with xenografts. The implant stability before and after graft procedure was measured by Osstell Mentor as implant stability quotient before bone graft (ISQ bbg) and implant stability quotient after bone graft (ISQ abg). Peri-apical radiographs were taken to measure peri-implant bone change immediately after implant surgery and 12 months after implant placement. Data were analyzed by independent t test; the relationships between stability parameters (insertion torque value (ITV), ISQ abg, and ISQ bbg) and peri-implant bone changes were analyzed according to Pearson correlation coefficients. The increase of ISQ in low primary stability group (LPSG) was 6.87 ± 3.62, which was significantly higher than the increase in high primary stability group (HPSG). A significant correlation between ITV and ISQ bbg ( R = 0.606, P = 0.002) was found; however, age and peri-implant bone change were not found significantly related to implant stability parameters. It was presented that there were no significant peri-implant bone changes at 1 year after bone graft surgery. Bone graft procedure is beneficial for increasing the primary stability of immediately placed implants, especially when the ISQ of implants is below 65 and that bone grafts have some effects on peri-implant bone maintenance.
Parabkaharan, Sangeetha; Melody, Megan; Trotta, Rose; Lleshi, Amina; Sun, Weihong; Smith, Paul D; Khakpour, Nazanin; Dayicioglu, Deniz
2016-06-01
Women who have undergone prior augmentation mammoplasty represent a unique subset of breast cancer patients with several options available for breast reconstruction. We performed a single institution review of surgical outcomes of breast reconstruction performed in patients with breast cancer with prior history of subpectoral breast augmentation. Institutional review board-approved retrospective review was conducted among patients with previously mentioned criteria treated at our institution between 2000 and 2014. Reconstructions were grouped into 2 categories as follows: (1) removal of preexisting subpectoral implant during mastectomy with immediate tissue expander placement and (2) implant-sparing mastectomy followed by delayed exchange to a larger implant. We reviewed demographics, tumor features, and reconstruction outcomes of these groups. Fifty-three patients had preexisting subpectoral implants. Of the 63 breast reconstructions performed, 18 (28.6%) had immediate tissue expander placed and 45 (71.4%) had implant-sparing mastectomy followed by delayed implant exchange. The groups were comparable based on age, body mass index, cancer type, tumor grade, TNM stage at presentation, and hormonal receptor status. No significant difference was noted between tumor margins or subsequent recurrence, mastectomy specimen weight, removed implant volume, volume of implant placed during reconstruction, or time from mastectomy to final implant placement. Rates of complications were significantly higher in the tissue expander group compared to the implant-sparing mastectomy group 7 (38.9%) versus 4 (8.9%) (P = 0.005). Implant-sparing mastectomy with delayed implant exchange in patients with preexisting subpectoral implants is safe and has fewer complications compared to tissue expander placement. There was no difference noted in the final volume of implant placed, time interval for final implant placement, or tumor margins.
Lee, Ji-Hye; Lee, Won; Huh, Yoon-Hyuk; Park, Chan-Jin; Cho, Lee-Ra
2017-09-05
To evaluate the axial displacement of the implant-abutment assembly of different implant diameter after static and cyclic loading of overload condition. An internal conical connection system with three diameters (Ø 4.0, 4.5, and 5.0) applying identical abutment dimension and the same abutment screw was evaluated. Axial displacement of abutment and reverse torque loss of abutment screw were evaluated under static and cyclic loading conditions. Static loading test groups were subjected to vertical static loading of 250, 400, 500, 600, 700, and 800 N consecutively. Cyclic loading test groups were subjected to 500 N cyclic loading to evaluate the effect of excessive masticatory loading. After abutment screw tightening for 30 Ncm, axial displacement was measured upon 1, 3, 10, and 1,000,000 cyclic loadings of 500 N. Repeated-measure ANOVA and 2-way ANOVA were used for statistical analysis (α = 0.05). The increasing magnitude of vertical load and thinner wall thickness of implant increased axial displacement of abutment and reverse torque loss of abutment screw (p < 0.05). Implants in the Ø 5.0 diameter group demonstrated significantly low axial displacement, and reverse torque loss after static loading than Ø 4.0 and Ø 4.5 diameter groups (p < 0.05). In the cyclic loading test, all diameter groups of implant showed significant axial displacement after 1 cycle of loading of 500 N (p < 0.05). There was no significant axial displacement after 3, 10, or 1,000,000 cycles of loading (p = 0.603). Implants with Ø 5.0 diameter demonstrated significantly low axial displacement and reverse torque loss after the cyclic and static loading of overload condition. © 2017 by the American College of Prosthodontists.
Braga, Giordana Campos; Ferriolli, Eduardo; Quintana, Silvana Maria; Ferriani, Rui Alberto; Pfrimer, Karina; Vieira, Carolina Sales
2015-12-01
Breast milk volume has never been evaluated when the etonogestrel (ENG) implant was inserted immediately postpartum. Thus, this study evaluated if the immediate postpartum insertion of the ENG implant alters breast milk volume. Twenty-four postpartum women and their newborns (NBs) were randomized into two groups: Implant group (ENG implant inserted within 48 h after delivery) and Control group (absence of contraceptive method). The primary outcome was the amount of breast milk intake by the NBs in the first 6 weeks after delivery. Five and ten grams of deuterium (D(2)O) were orally administered to the postpartum women on the day of randomization (day 0) and on the 29th study day, respectively. Saliva samples were collected from the mother-NB pairs prior to each D(2)O dose administration and after D(2)O ingestion (periodic collection). The amount of breast milk ingested by the NBs was estimated by the amount of deuterium (D(2)O) ingested by the NBs through breastfeeding, using mass spectrometry in the saliva samples. Twenty-four postpartum women and their NB were randomized (12 per group). The median of breast milk intake by NBs following the two D(2)O doses were similar between groups {first D(2)O dose [Implant: 340 mL/day (240-420 mL/day) vs. 330 mL/day (300-530 mL/day), p=.54]; second D(2)O dose [Implant: 845 mL/day (770-980 mL/day) vs. 785 mL/day (680-980 mL/day), p=.63]}. The exclusive breastfeeding rate and NB weight were similar between groups in the first 6 weeks postpartum. ENG implant insertion immediately postpartum does not alter the volume of breast milk intake by NBs. Considering the benefits of immediate postpartum initiation of ENG implant on reducing unintended pregnancy and pregnancy recurrence, especially in vulnerable populations, our study adds safety data on breastfeeding effect of this practice. Copyright © 2015 Elsevier Inc. All rights reserved.
Lee, Jaebum; Decker, John F; Polimeni, Giuseppe; Cortella, Carlo Alberto; Rohrer, Michael D; Wozney, John M; Hall, Jan; Susin, Cristiano; Wikesjö, Ulf M E
2010-06-01
Implants coated with recombinant human bone morphogenetic protein-2 (rhBMP-2) induce relevant bone formation but also resident bone remodelling. To compare the effect of implants fully or partially coated with rhBMP-2 on new bone formation and resident bone remodelling. Twelve, male, adult, Hound Labrador mongrel dogs were used. Critical-size, supraalveolar, peri-implant defects received titanium porous oxide surface implants coated in their most coronal aspect with rhBMP-2 (coronal-load/six animals) or by immersion of the entire implant in an rhBMP-2 solution (soak-load/six animals) for a total of 30 mug rhBMP-2/implant. All implants were air-dried. The animals were euthanized at 8 weeks for histometric evaluation. Clinical healing was uneventful. Supraalveolar bone formation was not significantly affected by the rhBMP-2 application protocol. New bone height and area averaged (+/- SE) 3.4 +/- 0.2 versus 3.5 +/- 0.4 mm and 2.6 +/- 0.4 versus 2.5 +/- 0.7 mm(2) for coronal-load and soak-load implants, respectively (p>0.05). The corresponding bone density and bone-implant contact (BIC) recordings averaged 38.0 +/- 3.8%versus 34.4 +/- 5.6% and 25.0 +/- 3.8%versus 31.2 +/- 3.3% (p>0.05). In contrast, resident bone remodelling was significantly influenced by the rhBMP-2 application protocol. Bone density outside the implants threads averaged 74.7 +/- 3.8% and 50.8 +/- 4.1% for coronal-load and soak-load implants, respectively (p<0.05); bone density within the thread area averaged 51.8 +/- 1.2% and 37.8 +/- 2.9%, and BIC 70.1 +/- 6.7% and 43.3 +/- 3.9% (p<0.05). Local application of rhBMP-2 appears to be a viable technology to support local bone formation and osseointegration. Coronal-load implants obviate resident bone remodelling without compromising new bone formation.
The Failure Envelope Concept Applied To The Bone-Dental Implant System.
Korabi, R; Shemtov-Yona, K; Dorogoy, A; Rittel, D
2017-05-17
Dental implants interact with the jawbone through their common interface. While the implant is an inert structure, the jawbone is a living one that reacts to mechanical stimuli. Setting aside mechanical failure considerations of the implant, the bone is the main component to be addressed. With most failure criteria being expressed in terms of stress or strain values, their fulfillment can mean structural flow or fracture. However, in addition to those effects, the bony structure is likely to react biologically to the applied loads by dissolution or remodeling, so that additional (strain-based) criteria must be taken into account. While the literature abounds in studies of particular loading configurations, e.g. angle and value of the applied load to the implant, a general study of the admissible implant loads is still missing. This paper introduces the concept of failure envelopes for the dental implant-jawbone system, thereby defining admissible combinations of vertical and lateral loads for various failure criteria of the jawbone. Those envelopes are compared in terms of conservatism, thereby providing a systematic comparison of the various failure criteria and their determination of the admissible loads.
Decker, John F; Lee, Jaebum; Cortella, Carlo Alberto; Polimeni, Giuseppe; Rohrer, Michael D; Wozney, John M; Hall, Jan; Susin, Cristiano; Wikesjö, Ulf M E
2010-12-01
Endosseous implants coated with recombinant human bone morphogenetic protein-2 (rhBMP-2) in a laboratory bench setting and air-dried induce relevant bone formation but also resident bone remodeling. Thus, the objective of this study is to evaluate the effect of implants fully or partially coated with rhBMP-2 and vacuum-dried using an industrial process on local bone formation and resident bone remodeling. Twelve male adult Hound Labrador mongrel dogs were used. Critical-size, supraalveolar, peri-implant defects received titanium porous oxide surface implants coated in their most coronal aspect with rhBMP-2 (coronal-load, six animals), or by immersion of the entire implant in a rhBMP-2 solution (soak-load, six animals) for a total of 30 μg rhBMP-2 per implant. All implants were vacuum-dried. The animals were sacrificed at 8 weeks for histometric evaluation. Clinical healing was unremarkable. Bone formation was not significantly affected by the rhBMP-2 application protocol. New bone height and area averaged (± SE) 3.2 ± 0.5 versus 3.6 ± 0.3 mm, and 2.3 ± 0.5 versus 2.6 ± 0.8 mm(2) for coronal-load and soak-load implants, respectively (P >0.05). The corresponding bone density and bone-implant contact registrations averaged 46.7% ± 5.8% versus 31.6% ± 4.4%, and 28% ± 5.6% versus 36.9% ± 3.4% (P >0.05). In contrast, resident bone remodeling was significantly influenced by the rhBMP-2 application protocol. Peri-implant bone density averaged 72.2% ± 2.1% for coronal-load versus 60.6% ± 4.7% for soak-load implants (P <0.05); the corresponding bone-implant contact averaged 70.7% ± 6.1% versus 47.2% ± 6.0% (P <0.05). Local application of rhBMP-2 and vacuum-drying using industrial process seems to be a viable technology to manufacture implants that support local bone formation and osseointegration. Coronal-load implants obviate resident bone remodeling without compromising local bone formation.
Cafiero, C; Annibali, S; Gherlone, E; Grassi, F R; Gualini, F; Magliano, A; Romeo, E; Tonelli, P; Lang, N P; Salvi, G E
2008-05-01
To assess the clinical and radiographic outcomes of immediate transmucosal placement of implants into molar extraction sockets. Twelve-month multicenter prospective cohort study. Following molar extraction, tapered implants with an endosseous diameter of 4.8 mm and a shoulder diameter of 6.5 mm were immediately placed into the sockets. Molars with evidence of acute periapical pathology were excluded. After implant placement and achievement of primary stability, flaps were repositioned and sutured allowing a non-submerged, transmucosal healing. Peri-implant marginal defects were treated according to the principles of guided bone regeneration (GBR) by means of deproteinized bovine bone mineral particles in conjunction with a bioresrobable collagen membrane. Standardized radiographs were obtained at baseline and 12 months thereafter. Changes in depth and width of the distance from the implant shoulder (IS) and from the alveolar crest (AC) to the bottom of the defect (BD) were assessed. Eighty-two patients (42 males and 40 females) were enrolled and followed for 12 months. They contributed with 82 tapered implants. Extraction sites displayed sufficient residual bone volume to allow primary stability of all implants. Sixty-four percent of the implants were placed in the areas of 36 and 46. GBR was used in conjunction with the placement of all implants. No post-surgical complications were observed. All implants healed uneventfully yielding a survival rate of 100% and healthy soft tissue conditions after 12 months. Radiographically, statistically significant changes (P<0.0001) in mesial and distal crestal bone levels were observed from baseline to the 12-month follow-up. The findings of this 12-month prospective cohort study showed that immediate transmucosal implant placement represented a predictable treatment option for the replacement of mandibular and maxillary molars lost due to reasons other than periodontitis including vertical root fractures, endodontic failures and caries.
In-vivo orthopedic implant diagnostic device for sensing load, wear, and infection
Evans, III, Boyd McCutchen; Thundat, Thomas G.; Komistek, Richard D.; Dennis, Douglas A.; Mahfouz, Mohamed
2006-08-29
A device for providing in vivo diagnostics of loads, wear, and infection in orthopedic implants having at least one load sensor associated with the implant, at least one temperature sensor associated with the implant, at least one vibration sensor associated with the implant, and at least one signal processing device operatively coupled with the sensors. The signal processing device is operable to receive the output signal from the sensors and transmit a signal corresponding with the output signal.
Scott, C E H; Eaton, M J; Nutton, R W; Wade, F A; Pankaj, P; Evans, S L
2013-10-01
As many as 25% to 40% of unicompartmental knee replacement (UKR) revisions are performed for pain, a possible cause of which is proximal tibial strain. The aim of this study was to examine the effect of UKR implant design and material on cortical and cancellous proximal tibial strain in a synthetic bone model. Composite Sawbone tibiae were implanted with cemented UKR components of different designs, either all-polyethylene or metal-backed. The tibiae were subsequently loaded in 500 N increments to 2500 N, unloading between increments. Cortical surface strain was measured using a digital image correlation technique. Cancellous damage was measured using acoustic emission, an engineering technique that detects sonic waves ('hits') produced when damage occurs in material. Anteromedial cortical surface strain showed significant differences between implants at 1500 N and 2500 N in the proximal 10 mm only (p < 0.001), with relative strain shielding in metal-backed implants. Acoustic emission showed significant differences in cancellous bone damage between implants at all loads (p = 0.001). All-polyethylene implants displayed 16.6 times the total number of cumulative acoustic emission hits as controls. All-polyethylene implants also displayed more hits than controls at all loads (p < 0.001), more than metal-backed implants at loads ≥ 1500 N (p < 0.001), and greater acoustic emission activity on unloading than controls (p = 0.01), reflecting a lack of implant stiffness. All-polyethylene implants were associated with a significant increase in damage at the microscopic level compared with metal-backed implants, even at low loads. All-polyethylene implants should be used with caution in patients who are likely to impose large loads across their knee joint.
Design and biomechanical evaluation of a cementable endosteal blade implant.
Pugh, J; Weiss, C; Weiss, F; Malkin, D
1976-07-01
A cementable endosteal blade implant has been developed and evaluated. Inherent in the design are the following factors: minimization of stress concentrators, ease of implantation, and high resistance to loosening. Other potential advantages of this design as compared with conventional endosteal blade implants include reduced hazards of postoperative infection and reduced likelihood of metallic corrosion. Six conventional endosteal implants and six cementable implants were installed in steer mandibles using standard dental surgical techniques and Simplex-brand methyl methacrylate bone cement. They were loaded in uniaxial compresstion at a loading rate of 0.0122 in./min. the stiffness (S), deformation at 900-lb load (D900), proportional limil (PL), and load at 0.04 in. deformation (L0.04) were calculated for each test. The cementable design showed a twofold increase in stiffness, only 17% of the deformation at 900lb, more than twice the proportional limit, and at least twice the load at 0.04 in. deformation when compared with similar values for the conventional endosteal implants. This study reveals that, in addition to being unstable in bone, conventional endosteal implants are also unstable when used with acrylic bone cement. The new design should eliminate most of the problems associated with endosteal blade implantation.
Kim, Ki-Tack; Lee, Sang-Hun; Suk, Kyung-Soo; Lee, Jung-Hee; Jeong, Bi-O
2010-06-01
The purpose of this study was to analyze the biomechanical effects of three different constrained types of an artificial disc on the implanted and adjacent segments in the lumbar spine using a finite element model (FEM). The created intact model was validated by comparing the flexion-extension response without pre-load with the corresponding results obtained from the published experimental studies. The validated intact lumbar model was tested after implantation of three artificial discs at L4-5. Each implanted model was subjected to a combination of 400 N follower load and 5 Nm of flexion/extension moments. ABAQUS version 6.5 (ABAQUS Inc., Providence, RI, USA) and FEMAP version 8.20 (Electronic Data Systems Corp., Plano, TX, USA) were used for meshing and analysis of geometry of the intact and implanted models. Under the flexion load, the intersegmental rotation angles of all the implanted models were similar to that of the intact model, but under the extension load, the values were greater than that of the intact model. The facet contact loads of three implanted models were greater than the loads observed with the intact model. Under the flexion load, three types of the implanted model at the L4-5 level showed the intersegmental rotation angle similar to the one measured with the intact model. Under the extension load, all of the artificial disc implanted models demonstrated an increased extension rotational angle at the operated level (L4-5), resulting in an increase under the facet contact load when compared with the adjacent segments. The increased facet load may lead to facet degeneration.
Lee, Jae-In; Lee, Yoon; Kim, Yu-Lee; Cho, Hye-Won
2016-02-01
The 4-, 3- or even 2-implant-supported partial fixed dental prosthesis (PFDP) designs have been used to rehabilitate the anterior edentulous maxilla. The purpose of this in vitro study was to compare the stress distribution in the supporting tissues surrounding implants placed in the anterior maxilla with 5 PFDP designs. A photoelastic model of the human maxilla with an anterior edentulous region was made with photoelastic resin (PL-2; Vishay Micro-Measurements), and 6 straight implants (OsseoSpeed; Astra Tech AB) were placed in the 6 anterior tooth positions. The 5 design concepts based on implant location were as follows: model 6I: 6 implants; model 2C2CI: 4 implants (2 canines and 2 central incisors); model 2C2LI: 4 implants (2 canines and 2 lateral incisors); model 2C1CI: 3 implants (2 canines and 1 central incisor); and model 2C: 2 canines. A load of 127.4 N was applied on the cingulum of 3 teeth at a 30-degree angle to the long axis of the implant. Stresses that developed in the supporting structure were recorded photographically. The 6-implant-supported PFDP exhibited the most even and lowest distribution of stresses in all loading conditions. When the canine was loaded, the 2- or 3-implant-supported PFDP showed higher stresses around the implant at the canine position than did the 4- or 6-implant-supported PFDP. When the central incisor or lateral incisor was loaded, the two 4-implant-supported PFDPs exhibited similar levels of stresses around the implants and showed lower stresses than did the 2- or 3-implant-supported PFDP. Implant number and distribution influenced stress distribution around the implants in the anterior maxilla. With a decrease in implant number, the stresses around the implants increased. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Fatigue induced changes in conical implant-abutment connections.
Blum, Kai; Wiest, Wolfram; Fella, Christian; Balles, Andreas; Dittmann, Jonas; Rack, Alexander; Maier, Dominik; Thomann, Ralf; Spies, Benedikt Christopher; Kohal, Ralf Joachim; Zabler, Simon; Nelson, Katja
2015-11-01
Based on the current lack of data and understanding of the wear behavior of dental two-piece implants, this study aims for evaluating the microgap formation and wear pattern of different implants in the course of cyclic loading. Several implant systems with different conical implant-abutment interfaces were purchased. The implants were first evaluated using synchrotron X-ray high-resolution radiography (SRX) and scanning electron microscopy (SEM). The implant-abutment assemblies were then subjected to cyclic loading at 98N and their microgap was evaluated after 100,000, 200,000 and 1 million cycles using SRX, synchrotron micro-tomography (μCT). Wear mechanisms of the implant-abutment connection (IAC) after 200,000 cycles and 1 million cycles were further characterized using SEM. All implants exhibit a microgap between the implant and abutment prior to loading. The gap size increased with cyclic loading with its changes being significantly higher within the first 200,000 cycles. Wear was seen in all implants regardless of their interface design. The wear pattern comprised adhesive wear and fretting. Wear behavior changed when a different mounting medium was used (brass vs. polymer). A micromotion of the abutment during cyclic loading can induce wear and wear particles in conical dental implant systems. This feature accompanied with the formation of a microgap at the IAC is highly relevant for the longevity of the implants. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Effect of cyclic load on vertical misfit of prefabricated and cast implant single abutment
DE JESUS TAVAREZ, Rudys Rodolfo; BONACHELA, Wellington Cardoso; XIBLE, Anuar Antônio
2011-01-01
Objective The purpose of this in vitro study was to evaluate misfit alterations at the implant/abutment interface of external and internal connection implant systems when subjected to cyclic loading. Material and Methods Standard metal crowns were fabricated for 5 groups (n=10) of implant/abutment assemblies: Group 1, external hexagon implant and UCLA cast-on premachined abutment; Group 2, internal hexagon implant and premachined abutment; Group 3, internal octagon implant and prefabricated abutment; Group 4, external hexagon implant and UCLA cast-on premachined abutment; and Group 5, external hexagon implant and Ceraone abutment. For groups 1, 2, 3 and 5, the crowns were cemented on the abutments and in group 4 crowns were screwed directly on the implant. The specimens were subjected to 500,000 cycles at 19.1 Hz of frequency and non-axial load of 133 N in a MTS 810 machine. The vertical misfit (μm) at the implant/abutment interface was evaluated before (B) and after (A) application of the cyclic loading. Data were analyzed statistically by using two-away ANOVA and Tukey’s post-hoc test (p<0.05). Results Before loading values showed no difference among groups 2 (4.33±3.13), 3 (4.79±3.43) and 5 (3.86±4.60); between groups 1 (12.88±6.43) and 4 (9.67±3.08), and among groups 2, 3 and 4. However, groups 1 and 4 were significantly different from groups 2, 3 and 5. After loading values of groups 1 (17.28±8.77) and 4 (17.78±10.99) were significantly different from those of groups 2 (4.83±4.50), 3 (8.07±4.31) and 5 (3.81±4.84). There was a significant increase in misfit values of groups 1, 3 and 4 after cyclic loading, but not for groups 2 and 5. Conclusion The cyclic loading and type of implant/abutment connection may develop a role on the vertical misfit at the implant/abutment interface. PMID:21437464
Stress Distribution Around Single Short Dental Implants: A Finite Element Study.
Vidya Bhat, S; Premkumar, Priyanka; Kamalakanth Shenoy, K
2014-12-01
Bone height restrictions are more common in the posterior regions of the mandible, because of either bone resorption resulting from tooth loss or even anatomic limitations, such as the position of the inferior alveolar nerve. In situations where adequate bone height is not available in the posterior mandible region, smaller lengths of implants may have to be used but it has been reported that the use of long implants (length ≥10 mm) is a positive factor in osseointegration and authors have reported failures with short implants. Hence knowledge about the stress generated on the bone with different lengths of implants needs scientific evaluation. The purpose of this study was to compare and evaluate the influence of different lengths of implants on stress upon bone in mandibular posterior area. A 3 D finite element model was made of the posterior mandible using the details from a CT scan, using computer software (ANSYS 12). Four simulated implants with lengths 6 mm, 8 mm, 10 mm and 13 mm were placed in the centre of the bone. A static vertical force of 250 N and a static horizontal force of 100 N were applied. The stress generated in the cortical and cancellous bone around the implant were recorded and evaluated with the help of ANSYS. In this study, Von Mises stress on a 6 mm implant under a static vertical load of 250 N appeared to be almost in the same range of 8 and 10 mm implant which were more as compared to 13 mm implant. Von Mises stress on a 6mm implant under a static horizontal load of 100 N appeared to be less when compared to 8, 10 and 13 mm implants. From the results obtained it may be inferred that under static horizontal loading conditions, shorter implants receive lesser load and thus may tend to transfer more stresses to the surrounding bone. While under static vertical loading the shorter implants bear more loads and comparatively transmit lesser load to the surrounding bone.
Graiff, Lorenzo; Vigolo, Paolo
2012-04-01
Placement of a dental implant and an interim restoration in the esthetic zone immediately following tooth extraction is now a common procedure. However, in such clinical situations, the fabrication of an appropriate interim restoration may be challenging. The aim of this article is to present a technique for modifying the extracted tooth so it can be used as an implant-supported interim restoration.
Sanz, Mariano; Lindhe, Jan; Alcaraz, Jaime; Sanz-Sanchez, Ignacio; Cecchinato, Denis
2017-08-01
To assess the added value of using a bone replacement graft in combination with immediate implants in reducing the bone dimensional changes occurring in the residual ridge. Randomized parallel controlled clinical trial to study the efficacy of grafting with demineralized bovine bone mineral with 10% collagen (DBBM-C) in the gap between the implant surface and the inner bone walls when the implants were immediately placed in the anterior maxilla. The changes between implant placement and 16 weeks later in the horizontal and vertical crestal bone changes in relation to the implant were evaluated through direct bone measurements using a periodontal probe. Mean changes were compared between the experimental and control sites using parametric statistics. A total of 86 implant sites in 86 subjects were included in the analysis (43 in the test group and 43 in the control group). The horizontal crest dimension underwent marked changes during healing mainly at the buccal aspect of the alveolar crest where this reduction amounted to 1.1 (29%) in the test group and 1.6 mm (38%) in the control group, being these statistically significant (P = 0.02). This outcome was even more pronounced at sites in the anterior maxilla and with thinner buccal bone plates. In conclusion, the results from this clinical trial demonstrated that placing a DBBM-C bone replacement graft significantly reduced the horizontal bone resorptive changes occurring in the buccal bone after the immediate implantation in fresh extraction sockets. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Sinking and fit of abutment of locking taper implant system
Moon, Seung-Jin; Kim, Hee-Jung; Son, Mee-Kyoung
2009-01-01
STATEMENT OF PROBLEM Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE In this study, Bicon® Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measured. MATERIAL AND METHODS 10 Bicon® implant fixtures were used. First, the abutment was connected to the fixture with finger force. Then it was tapped with a mallet for 3 times and loads of 20 kg corresponding to masticatory force using loading application instrument were applied successively. The abutment state, slightly connected to the fixture without pressure was considered as a reference length, and every new abutment length was measured after each load's step was added. The amount of abutment sinking (mm) was gained by subtracting the length of abutment-fixture under each loading condition from reference length. RESULTS It was evident, that the amount of abutment sinking in Bicon® Implant System increased as loads were added. When loads of 20 kg were applied more than 5 - 7 times, sinking stopped at 0.45 ± 0.09 mm. CONCLUSION Even though locking taper connection type implant shows good adaption to occlusal force, it has potential for abutment sinking as loads are given. When locking taper connection type implant is used, satisfactory loads are recommended for precise abutment location. PMID:21165262
Spinato, Sergio; Galindo-Moreno, Pablo; Bernardello, Fabio; Zaffe, Davide
This retrospective study quantitatively analyzed the minimum prosthetic abutment height to eliminate bone loss after 4.7-mm-diameter implant placement in maxillary bone and how grafting techniques can affect the marginal bone loss in implants placed in maxillary areas. Two different implant types with a similar neck design were singularly placed in two groups of patients: the test group, with platform-switched implants, and the control group, with conventional (non-platform-switched) implants. Patients requiring bone augmentation underwent unilateral sinus augmentation using a transcrestal technique with mineralized xenograft. Radiographs were taken immediately after implant placement, after delivery of the prosthetic restoration, and after 12 months of loading. The average mesial and distal marginal bone loss of the control group (25 patients) was significantly more than twice that of the test group (26 patients), while their average abutment height was similar. Linear regression analysis highlighted a statistically significant inverse relationship between marginal bone loss and abutment height in both groups; however, the intercept of the regression line, both mesially and distally, was 50% lower for the test group than for the control group. The marginal bone loss was annulled with an abutment height of 2.5 mm for the test group and 3.0 mm for the control group. No statistically significant differences were found regarding marginal bone loss of implants placed in native maxillary bone compared with those placed in the grafted areas. The results suggest that the shorter the abutment height, the greater the marginal bone loss in cement-retained prostheses. Abutment height showed a greater influence in platform-switched than in non-platform-switched implants on the limitation of marginal bone loss.
Comparison of load distribution for implant overdenture attachments.
Porter, Joseph A; Petropoulos, Vicki C; Brunski, John B
2002-01-01
The aim of this study was to compare the force and moment distributions that develop on different implant overdenture attachments when vertical compressive forces are applied to an implant-retained overdenture. The following attachments were examined: Nobel Biocare bar and clip (NBC), Nobel Biocare standard ball (NSB), Nobel Biocare 2.25-mm-diameter ball (NB2), Zest Anchor Advanced Generation (ZAAG), Sterngold ERA white (SEW), Sterngold ERA orange (SEO), Compliant Keeper System with titanium shims (CK-Ti), Compliant Keeper System with black nitrile 2SR90 sleeve rings (CK-70), and Compliant Keeper System with clear silicone 2SR90 sleeve rings (CK-90). The attachments were tested using custom strain-gauged abutments and 2 Brånemark System implants placed in a test model. Each attachment type had one part embedded in a denture-like housing and the other part (the abutment) screwed into the implants. Compressive static loads of 100 N were applied (1) bilaterally, over the distal midline (DM); (2) unilaterally, over the right implant (RI); (3) unilaterally, over the left implant (LI); and (4) between implants in the mid-anterior region (MA). Both the force and bending moment on each implant were recorded for each loading location and attachment type. Results were analyzed using 2-way analysis of variance and the Duncan multiple-range test. Both loading location and attachment type were statistically significant factors (P < .05). In general, the force and moment on an implant were greater when the load was applied directly over the implant or at MA. While not significant at every loading location, the largest implant forces tended to occur with ZAAG attachments; the smallest were found with the SEW, the SEO, the NSB, the CK-70, and the CK-90. Typically, higher moments existed for NBC and ZAAG, while lower moments existed for SEW, SEO, NSB, CK-90, and CK-70. For different loading locations, significant differences were found among the different overdenture attachment systems.
Micro finite element analysis of dental implants under different loading conditions.
Marcián, Petr; Wolff, Jan; Horáčková, Ladislava; Kaiser, Jozef; Zikmund, Tomáš; Borák, Libor
2018-05-01
Osseointegration is paramount for the longevity of dental implants and is significantly influenced by biomechanical stimuli. The aim of the present study was to assess the micro-strain and displacement induced by loaded dental implants at different stages of osseointegration using finite element analysis (FEA). Computational models of two mandible segments with different trabecular densities were constructed using microCT data. Three different implant loading directions and two osseointegration stages were considered in the stress-strain analysis of the bone-implant assembly. The bony segments were analyzed using two approaches. The first approach was based on Mechanostat strain intervals and the second approach was based on tensile/compression yield strains. The results of this study revealed that bone surrounding dental implants is critically strained in cases when only a partial osseointegration is present and when an implant is loaded by buccolingual forces. In such cases, implants also encounter high stresses. Displacements of partially-osseointegrated implant are significantly larger than those of fully-osseointegrated implants. It can be concluded that the partial osseointegration is a potential risk in terms of implant longevity. Copyright © 2018 Elsevier Ltd. All rights reserved.
Kelly, Andrew; Flanagan, Dennis
2013-02-01
Endosseous dental implants may require bone augmentation before implant placement. Herein is described an approach to edentulous ridge expansion with the use of piezosurgery and immediate placement of implants. This may allow for a shortened treatment time and the elimination of donor-site morbidity. Two cases are reported. This technique uses a piezoelectric device to cut the crestal and proximal facial cortices. Space is then created with motorized osteotomes to widen the split ridge. This technique allows for expansion of narrow, anatomically limiting, atrophic ridges, creating space for immediate implant placement. The facial and lingual cortices provide support with vital osteocytes for osteogenesis. The 2 patients presented had adequate bone height for implant placement but narrow edentulous ridges. In patient 1 at site #11, the ridge crest was 3.12 mm thick and was expanded to accept a 4.3 mm × 13 mm implant. The resulting ridge width was 8.88 mm, which was verified using cone beam computerized tomography (CBCT). In patient 2 at site #8 and site #9, the narrow ridge was expanded using the same technique to accept 2 adjacent 3.5 mm × 14 mm implants. The implants were restored to a functional and esthetic outcome.
Effect of Cyclic Loading on Micromotion at the Implant-Abutment Interface.
Karl, Matthias; Taylor, Thomas D
2016-01-01
Cyclic loading may cause settling of abutments mounted on dental implants, potentially affecting screw joint stability and implant-abutment micromotion. It was the goal of this in vitro study to compare micromotion of implant-abutment assemblies before and after masticatory simulation. Six groups of abutments (n = 5) for a specific tissue-level implant system with an internal octagon were subject to micromotion measurements. The implant-abutment assemblies were loaded in a universal testing machine, and an apparatus and extensometers were used to record displacement. This was done twice, in the condition in which they were received from the abutment manufacturer and after simulated loading (100,000 cycles; 100 N). Statistical analysis was based on analysis of variance, two-sample t tests (Welch tests), and Pearson product moment correlation (α = .05). The mean values for micromotion ranged from 33.15 to 63.41 μm and from 30.03 to 42.40 μm before and after load cycling. The general trend toward reduced micromotion following load cycling was statistically significant only for CAD/CAM zirconia abutments (P = .036) and for one type of clone abutment (P = .012), with no significant correlation between values measured before and after cyclic loading (Pearson product moment correlation; P = .104). While significant differences in micromotion were found prior to load cycling, no significant difference among any of the abutment types tested could be observed afterward (P > .05 in all cases). A quantifiable settling effect at the implant-abutment interface seems to result from cyclic loading, leading to a decrease in micromotion. This effect seems to be more pronounced in low-quality abutments. For the implant system tested in this study, retightening of abutment screws is recommended after an initial period of clinical use.
Pettoello-Mantovani, M; Kollmann, T R; Raker, C; Kim, A; Yurasov, S; Tudor, R; Wiltshire, H; Goldstein, H
1997-01-01
Treatment with protease inhibitors alone or in combination with inhibitors of reverse transcriptase potently suppresses levels of human immunodeficiency virus (HIV) RNA in plasma and thereby may significantly delay the progression of HIV-mediated disease. To investigate the effect of treatment with the protease inhibitor saquinavir on HIV replication in the lymphoid tissues, we used a SCID-hu mouse model that we developed, in which human thymic and liver tissues (hu-thy/liv) were implanted under both kidney capsules in SCID mice (thy/liv-SCID-hu mice). These mice are populated in the periphery with large numbers of human T cells and develop disseminated HIV infection after intraimplant injection. thy/liv-SCID-hu mice with established HIV infection that were treated for 1 month with saquinavir had a significantly lower viral load present in the implanted hu-thy/liv and mouse spleen than did the untreated HIV-infected thy/liv-SCID-hu mice. To examine the capacity of acute treatment with saquinavir to prevent HIV infection, some thy/liv-SCID-hu mice were inoculated with HIV and then immediately started on saquinavir. Although treated mice had markedly lower viral loads in the thy/liv implants and spleens, HIV infection was not completely prevented. Thus, the effect of antiviral therapy on HIV infection in the major site of HIV replication, the lymphoid tissues, can be readily evaluated in our thy/liv-SCID-hu mice. These mice should prove to be a useful model for determining the in vivo effectiveness of different therapeutic interventions on acute and chronic HIV infection. PMID:9303378
Kuroshima, Shinichiro; Nakano, Takayoshi; Ishimoto, Takuya; Sasaki, Muneteru; Inoue, Maaya; Yasutake, Munenori; Sawase, Takashi
2017-01-15
The aim was to investigate the effect of groove designs on bone quality under controlled-repetitive load conditions for optimizing dental implant design. Anodized Ti-6Al-4V alloy implants with -60° and +60° grooves around the neck were placed in the proximal tibial metaphysis of rabbits. The application of a repetitive mechanical load was initiated via the implants (50N, 3Hz, 1800 cycles, 2days/week) at 12weeks after surgery for 8weeks. Bone quality, defined as osteocyte density and degree of biological apatite (BAp) c-axis/collagen fibers, was then evaluated. Groove designs did not affect bone quality without mechanical loading; however, repetitive mechanical loading significantly increased bone-to-implant contact, bone mass, and bone mineral density (BMD). In +60° grooves, the BAp c-axis/collagen fibers preferentially aligned along the groove direction with mechanical loading. Moreover, osteocyte density was significantly higher both inside and in the adjacent region of the +60° grooves, but not -60° grooves. These results suggest that the +60° grooves successfully transmitted the load to the bone tissues surrounding implants through the grooves. An optimally oriented groove structure on the implant surface was shown to be a promising way for achieving bone tissue with appropriate bone quality. This is the first report to propose the optimal design of grooves on the necks of dental implants for improving bone quality parameters as well as BMD. The findings suggest that not only BMD, but also bone quality, could be a useful clinical parameter in implant dentistry. Although the paradigm of bone quality has shifted from density-based assessments to structural evaluations of bone, clarifying bone quality based on structural bone evaluations remains challenging in implant dentistry. In this study, we firstly demonstrated that the optimal design of dental implant necks improved bone quality defined as osteocytes and the preferential alignment degree of biological apatite c-axis/collagen fibers using light microscopy, polarized light microscopy, and a microbeam X-ray diffractometer system, after application of controlled mechanical load. Our new findings suggest that bone quality around dental implants could become a new clinical parameter as well as bone mineral density in order to completely account for bone strength in implant dentistry. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Topkaya, Tolga; Solmaz, Murat Yavuz
2015-07-16
The present study evaluated the effects of ball anchor abutment attached to implants with a 4.30 mm diameter and 11 mm insert length on stress distribution in a patient without any remaining teeth in the lower jaw. In the study, the stress analysis was performed for five different configurations (2 with 4 implant-supported and 3 with 2 implant-supported) and three different loading types using ANSYS Workbench software. The stresses measured in the 4 implant-supported models were lower compared to the stresses measured in the 2 implant-supported models. The stresses on the implants intensified on the cervical region of the implants. When the effects of the loading sites on the stress were examined, the loading on the first molar tooth produced the highest stresses on the implants. Copyright © 2015 Elsevier Ltd. All rights reserved.
Capitena, Cara E; Gamett, Kevin; Pantcheva, Mina B
2016-10-01
To report a case of delayed presentation of a severed acrylic single-piece intraocular lens (IOL) haptic fragment causing corneal edema after uneventful phacoemulsification surgery. An 85-year-old male presented with inferior corneal decompensation six months after a reportedly uneventful phacoemulsification in his left eye. A distal haptic fragment of an acrylic single-piece posterior chamber intraocular lens was found in the inferior anterior chamber angle. Intraoperative examination revealed that the dislocated fragment originated from the temporal haptic, the remainder of which was adherent to the anterior surface of the capsular bag. The clipped edge of the haptic fragment showed a clean, flat surface, suggesting it was severed by a sharp object. The findings were considered consistent with cutting of the fragment during implantation presumably from improper lens loading, improper implantation technique, or defective implantation devices. This is the first case report of a foldable acrylic intraocular lens severed during routine uncomplicated cataract surgery that was not noted at the time of the surgery or in the immediate postoperative period. Delayed presentation of severed IOL fragments should be considered in cases of late onset corneal edema post-operatively, when other causes have been ruled out. Careful implantation technique and thorough examination of the intraocular lens after implantation to assess for lens damage intraoperatively is essential to avoid such rare complications.
Neiva, Rodrigo F.; Gil, Luiz Fernando; Tovar, Nick; Janal, Malvin N.; Marao, Heloisa Fonseca; Pinto, Nelson; Coelho, Paulo G.
2016-01-01
Aims. This study evaluated the effects of L-PRF presence and implant surface texture on bone healing around immediately placed implants. Methods. The first mandibular molars of 8 beagle dogs were bilaterally extracted, and implants (Blossom™, Intra-Lock International, Boca Raton, FL) were placed in the mesial or distal extraction sockets in an interpolated fashion per animal. Two implant surfaces were distributed per sockets: (1) dual acid-etched (DAE, micrometer scale textured) and (2) micrometer/nanometer scale textured (Ossean™ surface). L-PRF (Intraspin system, Intra-Lock International) was placed in a split-mouth design to fill the macrogap between implant and socket walls on one side of the mandible. The contralateral side received implants without L-PRF. A mixed-model ANOVA (at α = 0.05) evaluated the effect of implant surface, presence of L-PRF, and socket position (mesial or distal), individually or in combination on bone area fraction occupancy (BAFO). Results. BAFO values were significantly higher for the Ossean relative to the DAE surface on the larger mesial socket. The presence of L-PRF resulted in higher BAFO. The Ossean surface and L-PRF presence resulted in significantly higher BAFO. Conclusion. L-PRF and the micro-/nanometer scale textured surface resulted in increased bone formation around immediately placed implants. PMID:28042577
Mangano, Francesco Guido; De Franco, Michele; Caprioglio, Alberto; Macchi, Aldo; Piattelli, Adriano; Mangano, Carlo
2014-07-01
This study evaluated the 1-year survival and success rate of root-analogue direct laser metal sintering (DLMS) implants, placed into the extraction sockets of 15 patients. DLMS is a technology which allows solids with complex geometry to be fabricated by annealing metal powder microparticles in a focused laser beam, according to a computer-generated three-dimensional (3D) model; the fabrication process involves the laser-induced fusion of titanium microparticles, in order to build, layer-by-layer, the desired object. Cone-beam computed tomography (CBCT) acquisition and 3D image conversion, combined with the DLMS process, allow the fabrication of custom-made, root-analogue implants (RAIs). CBCT images of 15 non-restorable premolars (eight maxilla; seven mandible) were acquired and transformed into 3D models: from these, custom-made, root-analogue DLMS implants with integral abutment were fabricated. Immediately after tooth extraction, the RAIs were placed in the sockets and restored with a single crown. One year after implant placement, clinical and radiographic parameters were assessed: success criteria included absence of pain, suppuration, and exudation; absence of implant mobility and absence of continuous peri-implant radiolucency; distance between the implant shoulder and the first visible bone-to-implant contact <1.5 mm from initial surgery; and absence of prosthetic complications. At the 1-year follow-up, no implants were lost, for a survival rate of 100 %. All implants were stable, with no signs of infection. The good conditions of the peri-implant tissues were confirmed by the radiographic examination, with a mean DIB of 0.7 mm (±0.2). The possibility of fabricating custom-made, RAI DLMS implants opens new interesting horizons for immediate placement of dental implants.
Long, Jason P.; Hollister, Scott J.; Goldstein, Steven A.
2012-01-01
While contemporary prosthetic devices restore some function to individuals who have lost a limb, there are efforts to develop bio-integrated prostheses to improve functionality. A critical step in advancing this technology will be to securely attach the device to remnant bone. To investigate mechanisms for establishing robust implant fixation in bone while undergoing loading, we previously used a topology optimization scheme to develop optimized orthopaedic implants and then fabricated selected designs from titanium (Ti)-alloy with selective laser sintering (SLS) technology. In the present study, we examined how implant architecture and mechanical stimulation influence osseointegration within an in vivo environment. To do this, we evaluated three implant designs (two optimized and one non-optimized) using a unique in vivo model that applied cyclic, tension/ compression loads to the implants. Eighteen (six per implant design) adult male canines had implants surgically placed in their proximal, tibial metaphyses. Experimental duration was 12 weeks; daily loading (peak load of ±22N for 1000 cycles) was applied to one of each animal’s bilateral implants for the latter six weeks. Following harvest, osseointegration was assessed by non-destructive mechanical testing, micro-computed tomography (microCT) and back-scatter scanning electron microscopy (SEM). Data revealed that implant loading enhanced osseointegration by significantly increasing construct stiffness, peri-implant trabecular morphology, and percentages of interface connectivity and bone ingrowth. While this experiment did not demonstrate a clear advantage associated with the optimized implant designs, osseointegration was found to be significantly influenced by aspects of implant architecture. PMID:22951278
Long, Jason P; Hollister, Scott J; Goldstein, Steven A
2012-10-11
While contemporary prosthetic devices restore some function to individuals who have lost a limb, there are efforts to develop bio-integrated prostheses to improve functionality. A critical step in advancing this technology will be to securely attach the device to remnant bone. To investigate mechanisms for establishing robust implant fixation in bone while undergoing loading, we previously used a topology optimization scheme to develop optimized orthopedic implants and then fabricated selected designs from titanium (Ti)-alloy with selective laser sintering (SLS) technology. In the present study, we examined how implant architecture and mechanical stimulation influence osseointegration within an in vivo environment. To do this, we evaluated three implant designs (two optimized and one non-optimized) using a unique in vivo model that applied cyclic, tension/compression loads to the implants. Eighteen (six per implant design) adult male canines had implants surgically placed in their proximal, tibial metaphyses. Experimental duration was 12 weeks; daily loading (peak load of ±22 N for 1000 cycles) was applied to one of each animal's bilateral implants for the latter six weeks. Following harvest, osseointegration was assessed by non-destructive mechanical testing, micro-computed tomography (microCT) and back-scatter scanning electron microscopy (SEM). Data revealed that implant loading enhanced osseointegration by significantly increasing construct stiffness, peri-implant trabecular morphology, and percentages of interface connectivity and bone ingrowth. While this experiment did not demonstrate a clear advantage associated with the optimized implant designs, osseointegration was found to be significantly influenced by aspects of implant architecture. Copyright © 2012 Elsevier Ltd. All rights reserved.
Delgado-Ruiz, Rafael Arcesio; Marković, Aleksa; Calvo-Guirado, José Luís; Lazić, Zoran; Piattelli, Adriano; Boticelli, Daniele; Maté-Sánchez, José Eduardo; Negri, Bruno; Ramírez-Fernández, María Piedad; Mišić, Tijana
2014-05-01
The modification of implant surfaces could affect mechanical implant stability as well as dynamics and quality of peri-implant bone healing. The aim of this 3-month experimental study in dogs was to investigate implant stability, marginal bone levels and bone tissue response to zirconia dental implants with two laser-micro-grooved intraosseous surfaces in comparison with nongrooved sandblasted zirconia and sandblasted, high-temperature etched titanium implants. Implant surface characterization was performed using optical interferometric profilometty and energy dispersive X-ray spectroscopy. A total of 96 implants (4 mm in diameter and 10 mm in length) were inserted randomly in both sides of the lower jaw of 12 Fox Hound dogs divided into groups of 24 each: the control (titanium), the group A (sandblasted zirconia), the group B (sandolasted zirconia plus microgrooved neck) and the group C (sandblasted zirconia plus all microgrooved). All the implants were immediately loaded. Insertion torque, periotest values, radiographic crestal bone level and removal torque were recorded during the 3-month follow-up. Qualitative scanning electon microscope (SEM) analysis of the bone-implant interfaces of each group was performed. Insertion torque values were higher in the group C and control implants (p < 0.05). Periotest values increased in all the periods in proportion to the extent of microgrooving as follows: the group C > the control > the group B > the group A (p < 0.05). Radiographic measurements showed minimal crestal bone loss at 3 months for microgrooved zirconia implants (groups C and B) and control implants compared with the group A implants (p < 0.05). The removal torque values increased with time for all the groups as follows: the group C > the control > the group B > the group A (p < 0.05). SEM showed that implant surfaces of the groups B and C had an extra bone growth inside the microgrooves that corresponded to the shape and direction of the microgrooves. The addition of microgrooves to the entire intraosseous surface of zirconia dental implants enhances primary and secondary implant stability, promotes bone tissue ingrowth and preserves crestal bone levels.
Nothdurft, Frank P; Doppler, Klaus E; Erdelt, Kurt J; Knauber, Andreas W; Pospiech, Peter R
2010-01-01
The aim of the study was to evaluate the influence of artificial aging on the fracture behavior of straight and angulated zirconia implant abutments used in ZirDesign (Astra Tech) implant/tooth-supported fixed partial dentures (FPDs) in the maxilla. Four different test groups (n = 8) representing anterior implant/tooth-supported FPDs were prepared. Groups 1 and 2 simulated a clinical situation with an ideal implant position (maxillary left central incisor) from a prosthetic point of view, which allowed for the use of a straight, prefabricated zirconia abutment. Groups 3 and 4 simulated a situation with a compromised implant position that required an angulated (20-degree) abutment. OsseoSpeed implants (4.5 3 13 mm, Astra Tech) as well as metal tooth analogs (maxillary right lateral incisor) with simulated periodontal mobility were mounted in polymethyl methacrylate. The FPDs (chromium-cobalt alloy) were cemented with glass ionomer. Groups 2 and 4 were thermomechanically loaded and subjected to static loading until failure. Statistical analysis of force data at the fracture site was performed using nonparametric tests. All samples survived thermomechanical loading. Artificial aging did not lead to a significant decrease in load-bearing capacity in either the straight abutments or the angulated abutments. The restorations that used angulated abutments exhibited higher fracture loads than the restorations with straight abutments (group 1: 209.13 ± 39.11 N; group 2: 233.63 ± 30.68 N; group 3: 324.62 ± 108.07 N; group 4: 361.75 ± 73.82 N). This difference in load-bearing performance was statistically significant, both with and without artificial aging. All abutment fractures occurred below the implant shoulder. Compensation for angulated implant positions with an angulated zirconia abutment is possible without reducing the load-bearing capacity of implant/tooth-supported anterior FPDs.
Short Implants Versus Standard Implants: Midterm Outcomes of a Clinical Study.
Benlidayi, M Emre; Ucar, Yurdanur; Tatli, Ufuk; Ekren, Orhun; Evlice, Burcu; Kisa, Halil Ibrahim; Baksi, Uygar
2018-02-01
The aim of this study was to evaluate the midterm survival rate, marginal bone resorption (MBR), and stability of short implants and to compare the results with standard length implants. A total of 38 patients were included. In total, 147 implants (Nucleoss Implants, Izmir, Turkey) were placed (86 short implants and 61 standard implants). Cement-retained metal-ceramic prostheses were fabricated. MBR was evaluated on periapical radiographs taken at implant placement, at the time of crown insertion and annually thereafter. The stability of the implants was evaluated by resonance frequency analysis. The 3- and 5-year cumulative survival rates for standard implants was 98.4% and for short implants was 96.5% (P = 0.644). The MBR of the short implants was significantly lower than that of the standard implants after 1, 2, and 3 years of loading (P < 0.05). No significant differences were found between 2 groups after 6 and 12 months of loading in terms of implant stability (implant stability quotient values) (P > 0.05). Within the limits of this study, it is concluded that short implants achieved similar results as standard implants after 3 to 5 years of loading.
Loading capacity of zirconia implant supported hybrid ceramic crowns.
Rohr, Nadja; Coldea, Andrea; Zitzmann, Nicola U; Fischer, Jens
2015-12-01
Recently a polymer infiltrated hybrid ceramic was developed, which is characterized by a low elastic modulus and therefore may be considered as potential material for implant supported single crowns. The purpose of the study was to evaluate the loading capacity of hybrid ceramic single crowns on one-piece zirconia implants with respect to the cement type. Fracture load tests were performed on standardized molar crowns milled from hybrid ceramic or feldspar ceramic, cemented to zirconia implants with either machined or etched intaglio surface using four different resin composite cements. Flexure strength, elastic modulus, indirect tensile strength and compressive strength of the cements were measured. Statistical analysis was performed using two-way ANOVA (p=0.05). The hybrid ceramic exhibited statistically significant higher fracture load values than the feldspar ceramic. Fracture load values and compressive strength values of the respective cements were correlated. Highest fracture load values were achieved with an adhesive cement (1253±148N). Etching of the intaglio surface did not improve the fracture load. Loading capacity of hybrid ceramic single crowns on one-piece zirconia implants is superior to that of feldspar ceramic. To achieve maximal loading capacity for permanent cementation of full-ceramic restorations on zirconia implants, self-adhesive or adhesive cements with a high compressive strength should be used. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Moraes, Sandra Lúcia Dantas de; Verri, Fellippo Ramos; Santiago, Joel Ferreira; Almeida, Daniel Augusto de Faria; Lemos, Cleidiel Aparecido Araujo; Gomes, Jéssica Marcela de Luna; Pellizzer, Eduardo Piza
2018-01-01
The aim of this study was to evaluate the effect of varying the diameter, connection type and loading on stress distribution in the cortical bone for implants with a high crown-implant ratio. Six 3D models were simulated with the InVesalius, Rhinoceros 3D 4.0 and SolidWorks 2011 software programs. Models were composed of bone from the posterior mandibular region; they included an implant of 8.5 mm length, diameter Ø 3.75 mm or Ø 5.00 mm and connection types such as external hexagon (EH), internal hexagon (IH) and Morse taper (MT). Models were processed using the Femap 11.2 and NeiNastran 11.0 programs and by using an axial force of 200 N and oblique force of 100 N. Results were recorded in terms of the maximum principal stress. Oblique loading showed high stress in the cortical bone compared to that shown by axial loading. The results showed that implants with a wide diameter showed more favorable stress distribution in the cortical bone region than regular diameter, regardless of the connection type. Morse taper implants showed better stress distribution compared to other connection types, especially in the oblique loading. Thus, oblique loading showed higher stress concentration in cortical bone tissue when compared with axial loading. Wide diameter implant was favorable for improved stress distribution in the cortical bone region, while Morse taper implants showed lower stress concentration than other connections.
Effect of placement angle on the stability of loaded titanium microscrews in beagle jaws.
Xu, Zhenrui; Wu, Yeke; Zhao, Lixing; Zhou, Yuqiao; Wei, Xing; Tang, Na; Feng, Xiaoxia; Tang, Tian; Zhao, Zhihe
2013-07-01
To evaluate the effect of insertion angle on stability of loaded titanium microscrews in beagle jaws. Forty-eight microscrews were inserted at four different angles (30°, 50°, 70°, and 90°) into the intraradicular zones of the mandibular first molars and third premolars of 12 beagles and immediately loaded with a force of 2 N for 8 weeks. Microcomputed tomography (micro-CT) and biomechanical pull-out tests were used to assess osseointegration of the interface. All micro-CT parameters and maximum pull-out force (FMAX) of the microscrews were affected by insertion angles of microscrews. Higher micro-CT parameters and FMAX were seen for implants inserted at angles between 50° and 70° (P < .05). Excessive oblique and vertical insertion angles resulted in reduced stability (P < .05). An insertion angle of 50° to 70° is more favorable than excessive oblique or vertical angles to achieve stability of microscrews.
Microleakage at the Different Implant Abutment Interface: A Systematic Review
Chowdhary, Ramesh; Kumari, Shail
2017-01-01
Introduction Presence of gap at the implant-abutment interface, leads to microleakage and accumulation of bacteria which can affect the success of dental implants. Aim To evaluate the sealing capability of different implant connections against microleakage. Materials and Methods In January 2017 an electronic search of literature was performed, in Medline, EBSCO host and Pubmed data base. The search was focused on ability of different implant connections in preventing microleakage. The related titles and abstracts available in English were screened, and the articles that fulfilled the inclusion criteria were selected for full text reading. Results In this systematic review, literature search initially resulted in 78 articles among which 30 articles only fulfilled the criteria for inclusion and were finally included in the review. Almost all the studies showed that there was some amount of microleakage at abutment implant interface. Microleakage was very less in Morse taper implants in comparison to other implant connections. Majority of studies showed less microleakage in static loading conditions and microleakage increases in dynamic loading conditions. Conclusion In this systematic review maximum studies showed that there was some amount of microleakage at abutment implant interface. External hexagon implants failed completely to prevent microleakage in both static and dynamic loading conditions of implants. Internal hexagon implants mainly internal conical (Morse taper) implants are very promising in case of static loading and also showed less microleakage in dynamic loading conditions. Torque recommended by manufacturer should be followed strictly to get a better seal at abutment implant interface. Zirconia abutments are more to microleakage than Titanium abutments and there use should be discouraged. Zirconia abutments should be only restricted to cases where there was very high demand of aesthetics. PMID:28764310
Dinato, Thiago R; Grossi, Márcio L; Teixeira, Eduardo R; Dinato, José C; Sczepanik, Fábio S C; Gehrke, Sergio A
2016-08-01
Sinus elevation is a reliable and often-used technique. Success of implants placed in such situations, even with bone substitutes alone, prompted the authors of this study to strive for bone loss close to zero and research variables that cause higher or lower rates of resorption. The objective of this study is to evaluate survival rates and marginal bone loss (MBL) around implants placed in sites treated with maxillary sinus augmentation using anorganic bovine bone (ABB), and identify surgical and prosthetic prognostic variables. Fifty-five implants were placed in 30 grafted maxillary sinuses in 24 patients. Periapical radiographs were evaluated immediately after implant placement (baseline), 6 months, and at the most recent follow-up. MBL was calculated from the difference between initial and final measurements, taking into account a distortion rate for each radiograph compared with original implant measurements. Survival rate was 98.2%, with only one implant lost (100% survival rate after loading) over a mean follow-up time of 2.0 ± 0.9 years. MBL ranged from 0 to 2.85 mm: 75.9% of mesial sites and 83.4% of distal sites showed <1 mm of MBL, whereas 35.2% of mesial sites and 37% of distal sites exhibited no bone loss. MBL was significantly (P <0.05) greater in open-flap compared with flapless surgery. Within the limitations of the present study, it was concluded that maxillary sinus elevation with 100% ABB gives predictable results, and that flapless surgery results in less MBL compared with traditional open-flap surgery.
Tilted orthodontic micro implants: a photoelastic stress analysis.
Çehreli, Seçil; Özçırpıcı, Ayça Arman; Yılmaz, Alev
2013-10-01
The aim of this study was to examine peri-implant stresses around orthodontic micro implants upon torque-tightening and static load application by quasi-three-dimensional photoelastic stress analysis. Self-tapping orthodontic micro implants were progressively inserted into photoelastic models at 30, 45, 70, and 90 degrees and insertion torques were measured. Stress patterns (isochromatic fringe orders) were recorded by the quasi-three-dimensional photoelastic method using a circular polariscope after insertion and 250 g static force application. Torque-tightening of implants generated peri-implant stresses. Upon insertion, 90 degree placed implants displayed the lowest and homogeneous stress distribution followed by 30, 70, and 45 degree tilted implants. Static loading did not dramatically alter stress fields around the implants tested. The highest alteration in stress distribution was observed for the 90 degree placed implant, while 70 degree tilted implant had the lowest stresses among tilted implants. Torque-tightening of orthodontic micro implants creates a stress field that is not dramatically altered after application of static lateral moderate orthodontic loads, particularly at the cervical region of tilted implants.
Torcato, Leonardo Bueno; Pellizzer, Eduardo Piza; Verri, Fellippo Ramos; Falcón-Antenucci, Rosse Mary; Santiago Júnior, Joel Ferreira; de Faria Almeida, Daniel Augusto
2015-11-01
Clinicians should consider parafunctional occlusal load when planning treatment. Prosthetic connections can reduce the stress distribution on an implant-supported prosthesis. The purpose of this 3-dimensional finite element study was to assess the influence of parafunctional loading and prosthetic connections on stress distribution. Computer-aided design software was used to construct 3 models. Each model was composed of a bone and an implant (external hexagon, internal hexagon, or Morse taper) with a crown. Finite element analysis software was used to generate the finite element mesh and establish the loading and boundary conditions. A normal force (200-N axial load and 100-N oblique load) and parafunctional force (1000-N axial and 500-N oblique load) were applied. Results were visualized as the maximum principal stress. Three-way analysis of variance and Tukey test were performed, and the percentage of contribution of each variable to the stress concentration was calculated from sum-of squares-analysis. Stress was concentrated around the implant at the cortical bone, and models with the external hexagonal implant showed the highest stresses (P<.001). Oblique loads produced high tensile stress concentrations on the site opposite the load direction. Internal connection implants presented the most favorable biomechanical situation, whereas the least favorable situation was the biomechanical behavior of external connection implants. Parafunctional loading increased the magnitude of stress by 3 to 4 times. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Paepoemsin, T; Reichart, P A; Chaijareenont, P; Strietzel, F P; Khongkhunthian, P
2016-01-01
The aim of this study was to evaluate the removal torque of three different abutment screws and pull out strength of implant-abutment connection for single implant restorations after mechanical cyclic loading. The study was performed in accordance with ISO 14801:2007. Three implant groups (n=15) were used: group A, PW Plus® with flat head screw; group B, PW Plus® with tapered screw; and group C, Conelog® with flat head screw. All groups had the same implant-abutment connection feature: cone with mandatory index. All screws were tightened with manufacturer's recommended torque. Ten specimens in each group underwent cyclic loading (1×106 cycles, 10 Hz, and 250 N). Then, all specimens were un-tightened, measured for the removal torque, and underwent a tensile test. The force that dislodged abutment from implant fixture was recorded. The data were analysed using independent sample t-test, ANOVA and Tukey HSD test. Before cyclic loading, removal torque in groups A, B and C were significantly different (B> A> C, P<.05). After cyclic loading, removal torque in all groups decreased significantly (P<.05). Group C revealed significantly less removal torque than groups A and B (P<.005). Tensile force in all groups significantly increased after cyclic loading (P<.05), group A had significantly less tensile force than groups B and C (P<.005). Removal torque reduced significantly after cyclic loading. Before cyclic loading, tapered screws maintained more preload than did flat head screws. After cyclic loading, tapered and flat head screws maintained even amounts of preload. The tensile force that dislodged abutment from implant fixture increased immensely after cyclic loading.
PAEPOEMSIN, T.; REICHART, P. A.; CHAIJAREENONT, P.; STRIETZEL, F. P.; KHONGKHUNTHIAN, P.
2016-01-01
SUMMARY Purpose The aim of this study was to evaluate the removal torque of three different abutment screws and pull out strength of implant-abutment connection for single implant restorations after mechanical cyclic loading. Methods The study was performed in accordance with ISO 14801:2007. Three implant groups (n=15) were used: group A, PW Plus® with flat head screw; group B, PW Plus® with tapered screw; and group C, Conelog® with flat head screw. All groups had the same implant-abutment connection feature: cone with mandatory index. All screws were tightened with manufacturer’s recommended torque. Ten specimens in each group underwent cyclic loading (1×106 cycles, 10 Hz, and 250 N). Then, all specimens were un-tightened, measured for the removal torque, and underwent a tensile test. The force that dislodged abutment from implant fixture was recorded. The data were analysed using independent sample t-test, ANOVA and Tukey HSD test. Results Before cyclic loading, removal torque in groups A, B and C were significantly different (B> A> C, P<.05). After cyclic loading, removal torque in all groups decreased significantly (P<.05). Group C revealed significantly less removal torque than groups A and B (P<.005). Tensile force in all groups significantly increased after cyclic loading (P<.05), group A had significantly less tensile force than groups B and C (P<.005). Conclusions Removal torque reduced significantly after cyclic loading. Before cyclic loading, tapered screws maintained more preload than did flat head screws. After cyclic loading, tapered and flat head screws maintained even amounts of preload. The tensile force that dislodged abutment from implant fixture increased immensely after cyclic loading. PMID:28042450
Enkling, Norbert; Saftig, Marcus; Worni, Andreas; Mericske-Stern, Regina; Schimmel, Martin
2017-04-01
This prospective study aimed to investigate the evolution of chewing efficiency, maximum voluntary bite force (MBF) and oral health-related quality of life (OHRQoL) in edentulous patients treated with narrow diameter implants (NDIs) over the course of 1 year. Four NDIs (MDI ® , 3M ESPE, diameter 1.8 mm) were placed interforaminally in 20 edentulous patients. They were immediately loaded by converting the existing prosthesis into an implant overdenture. Participants were examined six times pre- and postoperatively [baseline (BL) to week 52 (w52)]. Chewing efficiency was evaluated with a colour-mixing ability test by evaluation of the standard deviation of hue (VOH, ViewGum©). MBF was measured using a digital force gauge. OHRQoL was determined with the Oral Health Impact Profile (OHIPG49). Nonparametric Brunner-Langer models were applied for statistical testing. The study failed to demonstrate an effect on chewing efficiency. MBF increased continuously during the observation period (medians: MBF[N]@BL = 46.6 [iqr 50.1]; MBF[N]@w52 = 103.9 [iqr 76.0]; P = 0.002). OHRQoL increased steeply after implant loading and continued improving (medians: BL ∑OHIPG49 = 31 [iqr 40.0]; w4 ∑OHIPG49 = 11.5 [iqr 19.5]; w52 ∑OHIPG49 = 6 [iqr 13.0], P < 0.001). The stabilisation of a lower complete prosthesis with four NDIs is a feasible minimally invasive and economical approach to improve oral function and OHRQoL, especially in elderly patients with limited bone support. Functional benefits might be more evident if patients receive chewing instructions. Larger studies need to confirm a positive effect on chewing efficiency and develop long-term maintenance solutions if patients become frail because no easy downgrading approaches of one-piece titanium implants exist. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Zipprich, Holger; Miatke, Sven; Hmaidouch, Rim; Lauer, Hans-Christoph
2016-01-01
This study aimed to test bacterial microleakage at the implant-abutment interface (IAI) before and after dynamic loading using a new chewing simulation. Fourteen implant systems (n = 5 samples of each) were divided into two groups: (1) systems with conical implant-abutment connections (IACs), and (2) systems with flat IACs. For collecting samples without abutment disconnection, channels (Ø = 0.3 mm) were drilled into implants perpendicularly to their axes, and stainless-steel cannulas were adhesively glued inside these channels to allow a sterilized rinsing solution to enter the implant interior and to exit with potential contaminants for testing. Implants were embedded in epoxy resin matrices, which were supported by titanium cylinders with lateral openings for inward and outward cannulas. Abutments were tightened and then provided with vertically adjustable, threaded titanium balls, which were cemented using composite cement. Specimens were immersed in a bacterial liquid and after a contact time of 15 minutes, the implant interior was rinsed prior to chewing simulation (0 N ≘ static seal testing). Specimens were exposed to a Frankfurt chewing simulator. Two hundred twenty force cycles per power level (110 in ± X-axis) were applied to simulate a daily masticatory load of 660 chewing cycles (equivalent to 1,200,000 cycles/5 years). The applied load was gradually increased from 0 N to a maximum load of 200 N in 25-N increments. The implant interior was rinsed to obtain samples before each new power level. All samples were tested using fluorescence microscopy; invading microorganisms could be counted and evaluated. No bacterial contamination was detected under static loading conditions in both groups. After loading, bacterial contamination was detected in one sample from one specimen in group 1 and in two samples from two specimens in group 2. Controlled dynamic loading applied in this study simulated a clinical situation and enabled time-dependent analysis regarding the bacterial seal of different implant systems. Conical IACs offer a better bacterial seal compared with flat IACs, which showed increased microleakage after dynamic loading. IAC design plays a crucial role in terms of bacterial colonization. Taking samples of the implant interior without abutment disconnection eliminates an error source.
Kim, Ki-Seong; Han, Jung-Suk; Lim, Young-Jun
2014-01-01
The aim of this study was to evaluate and compare the settling of abutments into implants and the removal torque values (RTVs) before and after cyclic loading. Five different implant-abutment connections were tested: Ext = external butt joint + two-piece abutment; Int-H2 = internal hexagon + two-piece abutment; Int-H1 = internal hexagon + one-piece abutment; Int-O2 = internal octagon + two-piece abutment; and Int-O1 = internal octagon + one-piece abutment. Ten abutments from each group were secured to their corresponding implants (total n = 50). All samples were tested in a universal testing machine with a vertical load of 250 N for 100,000 cycles of 14 Hz. The amount of settling of the abutment into the implant was calculated from the change in the total length of the implant-abutment sample before and after loading, as measured with an electronic digital micrometer. The RTV after cyclic loading was compared to the initial RTV with a digital torque gauge. Statistical analysis was performed at a 5% significance level. A multiple-comparison test showed specific significant differences in settling values in each group after 250 N cyclic loading (Int-H1, Ext < Int-H2 < Int-O2 < Int-O1). There were statistically significant decreases in RTVs after loading compared to the initial RTVs in the Int-H2 and Int-O2 groups. No statistically significant differences were found in the Ext, Int-H1, and Int-O1 groups. The results of this study demonstrated that the settling amount and RTV (loss of preload) after cyclic loading were specific to the abutment type and related to the design characteristics of the implant-abutment connection.
Romanos, Georgios; Grizas, Eleftherios; Laukart, Elena; Nentwig, Georg-Hubertus
2016-04-01
This retrospective investigation aimed to evaluate the effect of early moderate loading (EML) on implant stability. Following 6 weeks of conventional healing, 634 dental implants (Ankylos®, Dentsply Implants, Mannheim, Germany) inserted in 247 patients were uncovered. Provisional restorations were placed in infra-occlusion in partially edentulous patients and in full occlusion in edentulous patients. Patients were instructed to consume a soft/liquid diet until final restorations were delivered after approximately 6 weeks. Periotest values (PTVs) at the time of uncovering and after EML were assessed in order to calculate the change in PTV (ΔPTV). Improvement of the PTV was analyzed to account for dependencies between measurements on multiple implants of a single patient, along with other factors. No implant was lost during the EML. After a mean loading time of 3 years (± 1.7 years), the implant survival rate was 98.74%. The PTV of 556 implants decreased (improved) over the course of the study. The ΔPTV was statistically significant (p = .0001), and none of the factors analyzed appeared to influence it. The EML of implants does not impair the implants' stability, as determined by Periotest. On the contrary, early moderate loading seems to be beneficial at compromised bone qualities. © 2015 Wiley Periodicals, Inc.
Matys, Jacek; Świder, Katarzyna; Flieger, Rafał; Dominiak, Marzena
2017-08-01
The implant primary stability is a fundamental prerequisite for a success of osseointegration process which determines the prosthetic reconstruction time. The aim of the present study was to assess the quality and precision of modern conical bone computer tomography (CBCT) software in preparing root analog zirconia implants (RAZIs) by measuring its primary stability by means of the Periotest device. Thirteen pig jaws with proper erupted first premolar (P1) teeth were used in the study. The CBCT examination was conducted in the area of the P1 tooth in each mandible. The 3-dimensional (3D) view of each tooth was designed from CBCT scan. The created 3D images were used to prepare root analog zirconia implants milled from a medical-grade zirconia block by means of laboratory milling. The RAZIs and titanium implants were placed into an alveolar socket after the tooth had been removed. The primary stability of the teeth before their extraction (G1), RAZIs (G2) and titanium implants (G3) were checked by Periotest devices. The mean results in PTV were: 15.9, 3.35, 12.7 for G1, G2 and G3 group, respectively. RAZIs during immediate loading achieved a significantly higher primary stability (lower Periotest value) as compared to the teeth and implants. The modern CBCT device allows us to design a precise image of an extracted tooth for the purpose of manufacturing a root analog implant. The additional feature of the surgical protocol using RAZI is the possibility of avoiding the augmentation procedure, which reduces the whole cost of the treatment.
Iraqui, O; Lakhssassi, N; Berrada, S; Merzouk, N
2016-06-01
The durability of dental implants depends on the presence of a 1mm coating bone sheath all around the fixture. Therefore, bone resorption represents a challenge for the practitioner. Bone expansion is a surgical technique that allows the management of horizontal bone atrophy. Cortical bone splitting allows for an enlargement of the residual crest by displacement of the vestibular bone flap. The immediate placement of implants secures the widening and allows for a 97% survival rate. However, bone expansion is hard to undertake in sites with high bone density. Furthermore, the use of traditional instruments increases patient's stress and the risk for an interruptive fracture during bone displacement. Non-traumatic bone expansion is one solution to this problem. The combination of piezo-surgery and conical expanders allows for a secured displacement of the selected bone flap as well as an immediate implant placement, avoiding the risk of slipping, overheating, or fracture, all within an undeniable operative comfort. Non-traumatic bone expansion is a reliable, reproducible, conservative, and economical in time and cost procedure. We describe our atraumatic bone expension and immediate implant placement technique in high bone density sites and illustrate it by a clinical case. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Influence of occlusal loading on peri-implant clinical parameters. A pilot study
Pellicer-Chover, Hilario; Viña-Almunia, José; Romero-Millán, Javier; Peñarrocha-Oltra, David; Peñarrocha-Diago, María
2014-01-01
Objectives: To investigate the relation between occlusal loading and peri-implant clinical parameters (probing depth, bleeding on probing, gingival retraction, width of keratinized mucosa, and crevicular fluid volume) in patients with implant-supported complete fixed prostheses in both arches. Material and Methods: This clinical study took place at the University of Valencia (Spain) dental clinic. It included patients attending the clinic for regular check-ups during at least 12 months after rehabilitation of both arches with implant-supported complete fixed ceramo-metallic prostheses. One study implant and one control implant were established for each patient using the T-Scan®III computerized system (Tesco, South Boston, USA). The maxillary implant closest to the point of maximum occlusal loading was taken as the study implant and the farthest (with least loading) as the control. Occlusal forces were registered with the T-Scan® III and then occlusal adjustment was performed to distribute occlusal forces correctly. Peri-implant clinical parameters were analyzed in both implants before and two and twelve months after occlusal adjustment. Results: Before occlusal adjustment, study group implants presented a higher mean volume of crevicular fluid (51.3±7.4 UP) than the control group (25.8±5.5 UP), with statistically significant difference. Two months after occlusal adjustment, there were no significant differences between groups (24.6±3.8 UP and 26±4.5 UP respectively) (p=0.977). After twelve months, no significant differences were found between groups (24.4±11.1 UP and 22.5±8.9 UP respectively) (p=0.323). For the other clinical parameters, no significant differences were identified between study and control implants at any of the study times (p>0.05). Conclusions: Study group implants receiving higher occlusal loading presented significantly higher volumes of crevicular fluid than control implants. Crevicular fluid volumes were similar in both groups two and twelve months after occlusal adjustment. Key words:Occlusal loading, crevicular fluid, peri-implant clinical parameters, T-Scan®. PMID:24316708
Hu, Chen; Gong, Ting; Lin, Weimin; Yuan, Quan; Man, Yi
2017-10-01
To evaluate bone reconstruction and soft tissue reactions at immediate implants placed into intact sockets and those with buccal bone dehiscence defects. Fifty-nine internal connection implants from four different manufacturers were immediately placed in intact sockets(non-dehiscence group, n=40), and in alveoli with buccal bone dehiscence defects: 1) Group 1(n= N10), the defect depth measured 3-5 mm from the gingival margin. 2) Group 2(n=9), the depth ranged from 5mm to 7mm. The surrounding bony voids were grafted with deproteinized bovine bone mineral (DBBM) particles. Cone beam computed tomography(CBCT) was performed immediately after surgery (T1), and at 6 months later(T2). Radiographs were taken at prosthesis placement and one year postloading(T3). Soft tissue parameters were measured at baseline (T0), prosthesis placement and T3. No implants were lost during the observation period. For the dehiscence groups, the buccal bone plates were radiographically reconstructed to comparable horizontal and vertical bone volumes compared with the non-dehiscence group. Marginal bone loss occurred between the time of final restoration and 1-year postloading was not statistically different(P=0.732) between groups. Soft tissue parameters did not reveal inferior results for the dehiscence groups. Within the limitations of this study, flapless implant placement into compromised sockets in combination with DBBM grafting may be a viable technique to reconstitute the defected buccal bone plates due to space maintenance and primary socket closure provided by healing abutments and bone grafts. Immediate implants and DBBM grafting without using membranes may be indicated for sockets with buccal bone defects. Copyright © 2017 Elsevier Ltd. All rights reserved.
Aunmeungtong, W; Khongkhunthian, P; Rungsiyakull, P
2016-01-01
Finite Element Analysis (FEA) has been used for prediction of stress and strain between dental implant components and bone in the implant design process. Purpose of this study was to characterize and analyze stress and strain distribution occurring in bone and implants and to compare stress and strain of three different implant designs. Three different mini dental implant designs were included in this study: 1. a mini dental implant with an internal implant-abutment connection (MDIi); 2. a mini dental implant with an external implant-abutment connection (MDIe); 3. a single piece mini dental implant (MDIs). All implant designs were scanned using micro-CT scans. The imaging details of the implants were used to simulate models for FEA. An artificial bone volume of 9×9 mm in size was constructed and each implant was placed separately at the center of each bone model. All bone-implant models were simulatively loaded under an axial compressive force of 100 N and a 45-degree force of 100 N loading at the top of the implants using computer software to evaluate stress and strain distribution. There was no difference in stress or strain between the three implant designs. The stress and strain occurring in all three mini dental implant designs were mainly localized at the cortical bone around the bone-implant interface. Oblique 45° loading caused increased deformation, magnitude and distribution of stress and strain in all implant models. Within the limits of this study, the average stress and strain in bone and implant models with MDIi were similar to those with MDIe and MDIs. The oblique 45° load played an important role in dramatically increased average stress and strain in all bone-implant models. Mini dental implants with external or internal connections have similar stress distribution to single piece mini dental implants. In clinical situations, the three types of mini dental implant should exhibit the same behavior to chewing force.
Vignoletti, Fabio; Discepoli, Nicola; Müller, Anna; de Sanctis, Massimo; Muñoz, Fernando; Sanz, Mariano
2012-01-01
The purpose of this investigation is to describe histologically the undisturbed healing of fresh extraction sockets when compared to immediate implant placement. In eight beagle dogs, after extraction of the 3P3 and 4P4, implants were inserted into the distal sockets of the premolars, while the mesial sockets were left to heal spontaneously. Each animal provided four socket sites (control) and four implant sites (test). After 6 weeks, animals were sacrificed and tissue blocks were dissected, prepared for ground sectioning. The relative vertical buccal bone resorption in relation to the lingual bone was similar in both test and control groups. At immediate implant sites, however, the absolute buccal bone loss observed was 2.32 (SD 0.36) mm, what may indicate that while an apical shift of both the buccal and lingual bone crest occurred at the implant sites, this may not happen in naturally healing sockets. The results from this investigation showed that after tooth extraction the buccal socket wall underwent bone resorption at both test and control sites. This resorption appeared to be more pronounced at the implant sites, although the limitations of the histological evaluation method utilized preclude a definite conclusion. © 2011 John Wiley & Sons A/S.
Osman, Reham B; Elkhadem, Amr H; Ma, Sunyoung; Swain, Michael V
2013-01-01
The purpose of this study was to compare the stress and strain occurring in peri-implant bone and implants used to support maxillary overdentures. Three-dimensional finite element analysis (3D FEA) was used to compare one-piece zirconia and titanium implants. Two types of implants were simulated using a 3D FEA model: one-piece zirconia and titanium implants (diameter, 3.8 × 11.5 mm) with 2.25-mm diameter ball abutments. In each simulation four implants were placed bilaterally in the canine/premolar region of an edentulous maxillary model. Static loads were applied axially and 20 degrees buccolingually on the buccal slope of the lingual cusps of posterior teeth of the first quadrant. Von Mises stresses and equivalent strains generated in peri-implant bone and first principal stresses in the implants were calculated. Comparable stress and strain values were shown in the peri-implant bone for both types of implants. The maximum equivalent strain produced in the peri-implant region was mostly within the range for bone augmentation. Under oblique loading, maximum von Mises stresses and equivalent strain were more evident at the neck of the most distal implant on the loaded side. Under axial load, the stress and strain were transferred to the peri-implant bone around the apex of the implant. Maximum tensile stresses that developed for either material were well below their fracture strength. The highest stresses were mainly located at the distobuccal region of the neck for the two implant materials under both loading conditions. From a biomechanical point of view, ceramic implants made from yttrium-stabilized tetragonal polycrystalline zirconia may be a potential alternative to conventional titanium implants for the support of overdentures. This is particularly relevant for a select group of patients with a proven allergy to titanium. Prospective clinical studies are still required to confirm these in vitro results. Different simulations presenting various cortical bone thicknesses and implant designs are required to provide a better understanding of the biomechanics of zirconia implants.
Drago, Lorenzo; Boot, Willemijn; Dimas, Kostantinos; Malizos, Kostantinos; Hänsch, Gertrud M; Stuyck, Jos; Gawlitta, Debby; Romanò, Carlo L
2014-11-01
Implant-related infections represent one of the most severe complications in orthopaedics. A fast-resorbable, antibacterial-loaded hydrogel may reduce or prevent bacterial colonization and biofilm formation of implanted biomaterials. We asked: (1) Is a fast-resorbable hydrogel able to deliver antibacterial compounds in vitro? (2) Can a hydrogel (alone or antibacterial-loaded) coating on implants reduce bacterial colonization? And (3) is intraoperative coating feasible and resistant to press-fit implant insertion? We tested the ability of Disposable Antibacterial Coating (DAC) hydrogel (Novagenit Srl, Mezzolombardo, Italy) to deliver antibacterial agents using spectrophotometry and a microbiologic assay. Antibacterial and antibiofilm activity were determined by broth microdilution and a crystal violet assay, respectively. Coating resistance to press-fit insertion was tested in rabbit tibias and human femurs. Complete release of all tested antibacterial compounds was observed in less than 96 hours. Bactericidal and antibiofilm effect of DAC hydrogel in combination with various antibacterials was shown in vitro. Approximately 80% of the hydrogel coating was retrieved on the implant after press-fit insertion. Implant coating with an antibacterial-loaded hydrogel reduces bacterial colonization and biofilm formation in vitro. A fast-resorbable, antibacterial-loaded hydrogel coating may help prevent implant-related infections in orthopaedics. However, further validation in animal models and properly controlled human studies is required.
Displacement of dental implants in trabecular bone under a static lateral load in fresh bovine bone.
Engelke, Wilfried; Müller, Alois; Decco, Oscar A; Rau, María J; Cura, Andrea C; Ruscio, Mara L; Knösel, Michael
2013-04-01
The study aims to provide objective data for the displacement of titanium screw implants in trabecular bone specimens. One hundred Semados implants (Bego, Bremen, Germany) were inserted in bovine type IV bone specimens. All implants had a diameter of 3.75 mm; 50 implants had a length of 8.5 mm and 50 implants had a length of 15 mm. Insertion torque was determined at intervals of 10, 20, and 30 Ncm. Implants were loaded horizontally with 10, 20, and 30 N for 2 seconds. An indicator strip was attached to the implant abutment to allow direct observation of implant movement relative to the bone surface. Horizontal displacement was assessed with an accuracy of measurement of 10 µm. Seven implants got lost by visible loosening. Degree of displacement was subject to evaluation with all others. Those implants showed a mean displacement of 59 µm for 10 N (n = 100), 173 µm for 20 N (n = 99), and 211 µm for 30 N (n = 93). The mean displacement of 15-mm implants (16, 37, 51 µm) was significantly lower compared with 8.5-mm implants (103, 311, 396 µm) corresponding to 10, 20, and 30 N as lateral loads. Displacement of screw implants in trabecular bone can be detected and visualized using commercially available endoscopes with a high magnification. A lateral load of 20 N indicates a mean displacement of over 100 µm and therefore results in a critical displacement. © 2011 Wiley Periodicals, Inc.
Maxillary "All-On-Four" treatment using zygomatic implants. A mechanical analysis.
de Moraes, P H; Olate, S; Nóbilo, M de Arruda; Asprino, L; de Moraes, M; Barbosa, J de Albergaría
2016-04-01
Zygomatic implants may be used for dental rehabilitation in atrophic maxillae. The aim of this study was to establish experimentally the areas of stress distribution using 2 kinds of "All-On-Four" maxillary procedures. The best position to insert the implants was selected using polyurethane craniomaxillary models and surgical guides were made. Group 1 was designed with two posterior zygomatic implants and two conventional anterior implants, and group 2 with two posterior zygomatic implants and two anterior zygomatic implants. A titanium bar was built to link the 4 implants in both groups. Photoelastic replicas of these models were made and the implants were inserted using the surgical guides. An Instrom 4411 testing machine was used to perform a unilateral compressive loading at the level of the right first molar until 2mm of displacement was obtained. Group 1 showed a high strain concentration in the right lateral orbital region at the level of the apex of the zygomatic implant. Less strain was noticed at the apical levels of the conventional implants in the anterior sector and of the contralateral zygomatic implant. Group 2 showed high strains in the lateral inferior orbital area. The load was low in the alveolar bone sector. Zygomatic bone and paranasal structures are loaded at high levels when zygomatic implants are used to stabilize a full maxillary prosthodontic rehabilitation on 4 implants. The use of 4 zygomatic implants loads the alveolar bone to a lower extent and seems better suited from a mechanical point of view than the use of 2 zygomatic implants. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Experimental and numeric stress analysis of titanium and zirconia one-piece dental implants.
Mobilio, Nicola; Stefanoni, Filippo; Contiero, Paolo; Mollica, Francesco; Catapano, Santo
2013-01-01
To compare the stress in bone around zirconia and titanium implants under loading. A one-piece zirconia implant and a replica of the same implant made of commercially pure titanium were embedded in two self-curing acrylic resin blocks. To measure strain, a strain gauge was applied on the surface of the two samples. Loads of 50, 100, and 150 N, with orientations of 30, 45, and 60 degrees with respect to the implant axis were applied on the implant. Strain under all loading conditions on both samples was measured. Three-dimensional virtual replicas of both the implants were reproduced using the finite element method and inserted into a virtual acrylic resin block. All the materials were considered isotropic, linear, and elastic. The same geometry and loading conditions of the experimental setup were used to realize two new models, with the implants embedded within a virtual bone block. Very close values of strain in the two implants embedded in acrylic resin were obtained both experimentally and numerically. The stress states generated by the implants embedded in virtual bone were also very similar, even if the two implants moved differently. Moreover, the stress levels were higher on cortical bone than on trabecular bone. The stress levels in bone, generated by the two implants, appeared to be very similar. From a mechanical point of view, zirconia is a feasible substitute for titanium.
Effects of mechanical repetitive load on bone quality around implants in rat maxillae
Uto, Yusuke; Nakano, Takayoshi; Ishimoto, Takuya; Inaba, Nao; Uchida, Yusuke; Sawase, Takashi
2017-01-01
Greater understanding and acceptance of the new concept “bone quality”, which was proposed by the National Institutes of Health and is based on bone cells and collagen fibers, are required. The novel protein Semaphorin3A (Sema3A) is associated with osteoprotection by regulating bone cells. The aims of this study were to investigate the effects of mechanical loads on Sema3A production and bone quality based on bone cells and collagen fibers around implants in rat maxillae. Grade IV-titanium threaded implants were placed at 4 weeks post-extraction in maxillary first molars. Implants received mechanical loads (10 N, 3 Hz for 1800 cycles, 2 days/week) for 5 weeks from 3 weeks post-implant placement to minimize the effects of wound healing processes by implant placement. Bone structures, bone mineral density (BMD), Sema3A production and bone quality based on bone cells and collagen fibers were analyzed using microcomputed tomography, histomorphometry, immunohistomorphometry, polarized light microscopy and birefringence measurement system inside of the first and second thread (designated as thread A and B, respectively), as mechanical stresses are concentrated and differently distributed on the first two threads from the implant neck. Mechanical load significantly increased BMD, but not bone volume around implants. Inside thread B, but not thread A, mechanical load significantly accelerated Sema3A production with increased number of osteoblasts and osteocytes, and enhanced production of both type I and III collagen. Moreover, mechanical load also significantly induced preferential alignment of collagen fibers in the lower flank of thread B. These data demonstrate that mechanical load has different effects on Sema3A production and bone quality based on bone cells and collagen fibers between the inside threads of A and B. Mechanical load-induced Sema3A production may be differentially regulated by the type of bone structure or distinct stress distribution, resulting in control of bone quality around implants in jaw bones. PMID:29244883
Effects of mechanical repetitive load on bone quality around implants in rat maxillae.
Uto, Yusuke; Kuroshima, Shinichiro; Nakano, Takayoshi; Ishimoto, Takuya; Inaba, Nao; Uchida, Yusuke; Sawase, Takashi
2017-01-01
Greater understanding and acceptance of the new concept "bone quality", which was proposed by the National Institutes of Health and is based on bone cells and collagen fibers, are required. The novel protein Semaphorin3A (Sema3A) is associated with osteoprotection by regulating bone cells. The aims of this study were to investigate the effects of mechanical loads on Sema3A production and bone quality based on bone cells and collagen fibers around implants in rat maxillae. Grade IV-titanium threaded implants were placed at 4 weeks post-extraction in maxillary first molars. Implants received mechanical loads (10 N, 3 Hz for 1800 cycles, 2 days/week) for 5 weeks from 3 weeks post-implant placement to minimize the effects of wound healing processes by implant placement. Bone structures, bone mineral density (BMD), Sema3A production and bone quality based on bone cells and collagen fibers were analyzed using microcomputed tomography, histomorphometry, immunohistomorphometry, polarized light microscopy and birefringence measurement system inside of the first and second thread (designated as thread A and B, respectively), as mechanical stresses are concentrated and differently distributed on the first two threads from the implant neck. Mechanical load significantly increased BMD, but not bone volume around implants. Inside thread B, but not thread A, mechanical load significantly accelerated Sema3A production with increased number of osteoblasts and osteocytes, and enhanced production of both type I and III collagen. Moreover, mechanical load also significantly induced preferential alignment of collagen fibers in the lower flank of thread B. These data demonstrate that mechanical load has different effects on Sema3A production and bone quality based on bone cells and collagen fibers between the inside threads of A and B. Mechanical load-induced Sema3A production may be differentially regulated by the type of bone structure or distinct stress distribution, resulting in control of bone quality around implants in jaw bones.
Pre-load on oral implants after screw tightening fixed full prostheses: an in vivo study.
Duyck, J; Van Oosterwyck, H; Vander Sloten, J; De Cooman, M; Puers, R; Naert, I
2001-03-01
The fit of implant supported fixed prostheses is said to be of clinical concern because of the rigid fixation of an oral implant in its surrounding bone. The influence of the torque sequence of the set screws during fixation of implant supported fixed full prostheses on the final pre-load was investigated in vitro. No significant effect of the torque sequence of the set screws on the final pre-load was observed. The main objective of this study was to quantify and qualify the pre-load in vivo on implants supporting a fixed full prosthesis. This was performed when the prostheses were supported by all five or six implants and was repeated when the prostheses were supported by only four and three implants. A total of 13 patients with a fixed full implant supported prosthesis were selected. The existing abutments were changed for strain gauged abutments. After tightening the set screws with a torque of 10 N cm, the pre-load conditions were registered. The average (SEM) axial forces and bending moments in case of five or six, four and three supporting implants were 323 N (43 N), 346 N (59 N), 307 N (60 N) 21 N cm (3 N cm) and 21 N cm (2 N cm), 23 N cm (5 N cm), respectively. In addition, the pre-load was registered after fixation of a machined gold cylinder, as delivered by the manufacturer, on each of the supporting implants, representing the 'optimal fit' situation. The corresponding average (SEM) axial forces and bending moments in case of five or six, four and three supporting implants were 426 N (36 N), 405 N (40 N), 413 N (46 N) and 8 N cm (1 N cm), 8 N cm (1 N cm), 8 N cm (1 N cm), respectively. The induced axial forces after tightening the prostheses were significantly lower then after tightening the gold cylinder in case of five or six supporting implants (P < 0.02). The induced bending moments after tightening the prostheses were statistically significantly higher (P < 0.0001) then after tightening the gold cylinder in all test conditions (five or six, four or three supporting implants). This study underlines the static load present after screw tightening implant supported fixed full prostheses.
Tallarico, Marco; Meloni, Silvio Mario
To report survival rate, early surgical template-related complications, and prevalence of peri-implantitis of dental implants placed in private practices using computer-guided, template-assisted surgery and followed between 1 and 10 years. The present retrospective multicenter study evaluated data collected from fully or partially edentulous patients, with anodized-surface implants placed using computer-guided, template-assisted surgery between January 2006 and December 2015. The outcome measures were implant cumulative survival rate (CSR), early surgical complications involving the surgical template, and prevalence of peri-implantitis. A total of 694 implants were placed in 141 patients. Ten patients (7.1%) with 48 implants (6.9%) dropped out during the study period. One hundred seventeen patients, who received 121 surgical and prosthetic procedures, were treated according to a double-scan protocol, while the remaining 24 patients were treated by using the integrated treatment workflow. Most of the implants were immediately loaded (528 implants, 76.1%; 112 patients, 79.4%). Overall, 107 complete full-arch restorations (supported by four to eight implants each) were delivered in 103 patients (73%) with 595 implants (85.7%), while 13 single and 30 partial restorations (two to five implants each) were delivered in 38 patients (27%) with 99 implants (14.3%). Patients were followed for up to 10 years (mean: 58.2 months, range: 12 to 120 months). Implant- and patient-level CSR (Kaplan-Meier estimation) at the 10-year follow-up was 97.4% (95% CI: 1.0309 to 0.9161) and 92.1% (95% CI: 1.1575 to 0.6836), respectively. All failed implants were lost before definitive prosthesis delivery (early failure). Ten (7.1%) minor template-related complications were experienced and resolved chairside. Over the entire follow-up period, four patients (2.8%) with 12 implants (1.7%) showed signs of peri-implantitis at the 1- (four implants), 2- (four implants), and 4-year (four implants) visits. High long-term survival rates and low complications and prevalence of peri-implantitis were observed for a large cohort of anodized-surface implants placed in private practices. Further studies are needed to confirm these preliminary results.
The dynamic natures of implant loading.
Wang, Rui-Feng; Kang, Byungsik; Lang, Lisa A; Razzoog, Michael E
2009-06-01
A fundamental problem in fully understanding the dynamic nature of implant loading is the confusion that exists regarding the torque load delivered to the implant complex, the initial force transformation/stress/strain developed within the system during the implant complex assembly, and how the clamping forces at the interfaces and the preload stress impact the implant prior to any external loading. The purpose of this study was to create an accurately dimensioned finite element model with spiral threads and threaded bores included in the implant complex, positioned in a bone model, and to determine the magnitude and distribution of the force transformation/stress/strain patterns developed in the modeled implant system and bone and, thus, provide the foundational data for the study of the dynamic loading of dental implants prior to any external loading. An implant (Brånemark Mark III), abutment (CeraOne), abutment screw (Unigrip), and the bone surrounding the implant were modeled using HyperMesh software. The threaded interfaces between screw/implant and implant/bone were designed as a spiral thread helix assigned with specific coefficient of friction values. Assembly simulation using ABAQUS and LS-DYNA was accomplished by applying a 32-Ncm horizontal torque load on the abutment screw (Step 1), then decreasing the torque load to 0 Ncm to simulate the wrench removal (Step 2). The postscript data were collected and reviewed by HyperMesh. A regression analysis was used to depict the relationships between the torque load and the mechanical parameters. During the 32-Ncm tightening sequence, the abutment screw elongated 13.3 mum. The tightening torque generated a 554-N clamping force at the abutment/implant interface and a 522-N preload. The von Mises stress values were 248 MPa in the abutment at the abutment-implant interface, 765 MPa at the top of the screw shaft, 694 MPa at the bottom of the screw shaft, 1365 MPa in the top screw thread, and 21 MPa in the bone at the top of the implant-bone interface. This study also identified various characteristic isosurface stress patterns. The maximum stress magnitude to complete the von Mises stress joint pattern in the present model was 107 MPa during screw tightening, and was reduced to 104 MPa with removal of the wrench. Various specific stress patterns were identified within all elements of the implant complex during the assembly simulation. During the torque moment application, the abutment screw was elongated, and every 1.0-mum elongation of the screw was equivalent to a 47.9-N increase of the preload in the implant complex. The ideal index to determine the preload amount was the contact force at the interface between the screw threads and the threaded screw bore. The isosurface mode identified various characteristic stress patterns developed within the implant complex at the various interfaces during the assembly simulation. These patterns are the (1) spiral and ying-yang pattern of the XY stress, (2) spring, cap, clamping, and preload pattern of the ZZ stress, and (3) bone holding and joint pattern of the von Mises stress.
Sarnachiaro, Guido O; Chu, Stephen J; Sarnachiaro, Evangelina; Gotta, Sergio Luis; Tarnow, Dennis P
2016-08-01
To measure the buccal plate reconstruction of extraction sockets with labial plate dehiscence defects using a bone allograft in combination with an absorbable collagen membrane and a custom-healing abutment at the time of tooth removal. Ten patients underwent immediate implant placement and reconstruction of the buccal plate. Cone beam computed tomography (CBCT) was performed preextraction, immediately after bone grafting and implant placement (day 0), and between 6 and 9 months following implant surgery. Measurements were taken at three levels: coronal (L1), middle (L2), and apical (L3) level. Implants placed into sockets with labial plate dehiscence defects demonstrated radiographic reformation of the labial plate dehiscence defect at 6 to 9 months posttreatment. The net gain in labial plate on cone beam computerized tomography (CBCT) in L1 and L2 was 3.0 mm, where 0 mm existed at pretreatment. The minimum amount of labial plate thickness of 2.0 mm was achieved in all treated sites, evaluated radiographically at 6 to 9 months postoperatively, in a single procedure, without flap elevation and maintaining the gingival architecture and satisfactory esthetics. Placing an absorbable membrane, bone graft, and custom-healing abutment at the time of flapless anterior tooth extraction and immediate implant placement into a socket with a labial osseous dehiscence is a viable clinical technique to reconstitute the absence of the labial bone plate. © 2015 Wiley Periodicals, Inc.
Gil, Francisco Javier; Aparicio, Conrado; Manero, Jose M; Padros, Alejandro
2009-01-01
This study evaluated the effect of external hexagon height and commonly applied surface treatments on the fatigue life of titanium dental implants. Electropolished commercially pure titanium dental implants (seven implants per group) with three different external hexagon heights (0.6, 1.2, and 1.8 mm) and implants with the highest external hexagon height (1.8 mm) and different surface treatments (electropolishing, grit blasting with aluminium oxide, and acid etching with sulfuric acid) were tested to evaluate their mechanical fatigue life. To do so, 10-Hz triangular flexural load cycles were applied at 37 degrees C in artificial saliva, and the number of load cycles until implant fracture was determined. Tolerances of the hexagon/abutment fit and implant surface roughness were analyzed by scanning electron microscopy and light interferometry. Transmission electron microscopy and electron diffraction analyses of titanium hydrides were performed. First, the fatigue life of implants with the highest hexagon (8,683 +/- 978 load cycles) was more than double that of the implants with the shortest hexagons (3,654 +/- 789 load cycles) (P < .02). Second, the grit-blasted implants had the longest fatigue life of the tested materials (21,393 +/- 2,356 load cycles), which was significantly greater than that of the other surfaces (P < .001). The compressive surface residual stresses induced when blasting titanium are responsible for this superior mechanical response. Third, precipitation of titanium hydrides in grain boundaries of titanium caused by hydrogen adsorption from the acid solution deteriorates the fatigue life of acid-etched titanium dental implants. These implants had the shortest fatigue life (P < .05). The fatigue life of threaded root-form dental implants varies with the height of the external hexagon and/or the surface treatment of the implant. An external hexagon height of 1.8 mm and/or a blasting treatment appear to significantly increase fatigue life of dental implants.
Fracture toughness of titanium-cement interfaces: effects of fibers and loading angles.
Khandaker, Morshed; Utsaha, Khatri Chhetri; Morris, Tracy
2014-01-01
Ideal implant-cement or implant-bone interfaces are required for implant fixation and the filling of tissue defects created by disease. Micron- to nanosize osseointegrated features, such as surface roughness, fibers, porosity, and particles, have been fused with implants for improving the osseointegration of an implant with the host tissue in orthopedics and dentistry. The effects of fibers and loading angles on the interface fracture toughness of implant-cement specimens with and without fibers at the interface are not yet known. Such studies are important for the design of a long-lasting implant for orthopedic applications. The goal of this study was to improve the fracture toughness of an implant-cement interface by deposition of micron- to nanosize fibers on an implant surface. There were two objectives in the study: 1) to evaluate the influence of fibers on the fracture toughness of implant-cement interfaces with and without fibers at the interfaces, and 2) to evaluate the influence of loading angles on implant-cement interfaces with and without fibers at the interfaces. This study used titanium as the implant, poly(methyl methacrylate) (PMMA) as cement, and polycaprolactone (PCL) as fiber materials. An electrospinning unit was fabricated for the deposition of PCL unidirectional fibers on titanium (Ti) plates. The Evex tensile test stage was used to determine the interface fracture toughness (KC) of Ti-PMMA with and without PCL fibers at 0°, 45°, and 90° loading angles, referred to in this article as tension, mixed, and shear tests. The study did not find any significant interaction between fiber and loading angles (P>0.05), although there was a significant difference in the KC means of Ti-PMMA samples for the loading angles (P<0.05). The study also found a significant difference in the KC means of Ti-PMMA samples with and without fibers (P<0.05). The results showed that the addition of the micron- to nanosize PCL fibers on Ti improved the quality of the Ti-PMMA union. The results of the study are essential for fatigue testing and finite-element analysis of implant-cement interfaces to evaluate the performance of orthopedic and orthodontic implants.
Borges Radaelli, Manuel Tomás; Idogava, Henrique Takashi; Spazzin, Aloisio Oro; Noritomi, Pedro Yoshito; Boscato, Noéli
2018-04-30
An occlusal device is frequently recommended for patients with bruxism to protect implant-supported restorations and prevent marginal bone loss. Scientific evidence to support this treatment is lacking. The purpose of this 3-dimensional (3D) finite element study was to evaluate the influence of an acrylic resin occlusal device, implant length, and insertion depth on stress distribution with functional and parafunctional loadings. Computer-aided design software was used to construct 8 models. The models were composed of a mandibular bone section including the second premolar and first and second molars. Insertion depths (bone level and 2 mm subcrestal) were simulated at the first molar. Three natural antagonist maxillary teeth and the placement or not of an occlusal device were simulated. Functional (200-N axial and 10-N oblique) and parafunctional (1000-N axial and 25-N oblique) forces were applied. Finite element analysis (FEA) was used to determine the maximum principal stress for the cortical and trabecular bone and von Mises for implant and prosthetic abutment. Stress concentration was observed at the abutment-implant and the implant-bone interfaces. Occlusal device placement changed the pattern of stress distribution and reduced stress levels from parafunctional loading in all structures, except in the trabecular bone. Implants with subcrestal insertion depths had reduced stress at the implant-abutment interface and cortical bone around the implant abutment, while the stress increased in the bone in contact with the implant. Parafunctional loading increased the stress levels in all structures when compared with functional loading. An occlusal device resulted in the lowest stress levels at the abutment and implant and the most favorable stress distribution between the cortical and trabecular bone. Under parafunctional loading, an occlusal device was more effective in reducing stress distribution for longer implants inserted at bone level. Subcrestally, implant insertion yielded the most favorable biomechanical conditions at the abutment-implant interface and at the coronal surface of the cortical bone, mainly when there was no occlusal device. Copyright © 2018 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Mehdi, Ghalem; Belarbi, Abderrahmane; Mansouri, Bensmaine; Azari, Zitouni
2015-01-01
This paper focused on optimal stress distribution in the mandibular bone surrounding a dental implant and is devoted to the development of a modified Osteoplant® implant type in order to minimize stress concentration in the bone-implant interface. This study investigated 0.4 mm thick layers of two elastomeric stress barriers incorporated into the dental implant using 3-D finite element analysis. Overall, this proposed implant provoked lower load transfer in bone-implant interface due to the effect of the elastomers as stress absorbers. The stress level in the bone was reduced between 28% and 42% for three load cases: 75 N, 60 N and 27 N in corono-apical, linguo-buccal and disto-mesial direction, respectively. The proposed model provided an acceptable solution for load transfer reduction to the mandible. This investigation also permitted to choose how to incorporate two elastomers into the Osteoplant® implant system.
Shah, Farhan Khalid; Gebreel, Ashraf; Elshokouki, Ali hamed; Habib, Ahmed Ali
2012-01-01
PURPOSE To compare the changes in the occlusal vertical dimension, activity of masseter muscles and biting force after insertion of immediate denture constructed with conventional, tooth-supported and Implant-supported immediate mandibular complete denture. MATERIALS AND METHODS Patients were selected and treatment was carried out with all the three different concepts i.e, immediate denture constructed with conventional (Group A), tooth-supported (Group B) and Implant-supported (Group C) immediate mandibular complete dentures. Parameters of evaluation and comparison were occlusal vertical dimension measured by radiograph (at three different time intervals), Masseter muscle electromyographic (EMG) measurement by EMG analysis (at three different positions of jaws) and bite force measured by force transducer (at two different time intervals). The obtained data were statistically analyzed by using ANOVA-F test at 5% level of significance. If the F test was significant, Least Significant Difference test was performed to test further significant differences between variables. RESULTS Comparison between mean differences in occlusal vertical dimension for tested groups showed that it was only statistically significant at 1 year after immediate dentures insertion. Comparison between mean differences in wavelet packet coefficients of the electromyographic signals of masseter muscles for tested groups was not significant at rest position, but significant at initial contact position and maximum voluntary clench position. Comparison between mean differences in maximum biting force for tested groups was not statistically significant at 5% level of significance. CONCLUSION Immediate complete overdentures whether tooth or implant supported prosthesis is recommended than totally mucosal supported prosthesis. PMID:22737309
Gao, Li; Xia, Lunyang; Zhang, Ruhui; Duan, Dandan; Liu, Xiuxiu; Xu, Jianjian; Luo, Lan
2017-01-01
Purpose Methotrexate is widely used in chemotherapy for a variety of malignancies. However, severe toxicity, poor pharmacokinetics, and narrow safety margin of methotrexate limit its clinical application. The aim of this study was to develop sustained-release methotrexate-loaded implants and evaluate antitumor activity of the implants after intratumoral implantation. Materials and methods We prepared the implants containing methotrexate, poly(D,L-lactide-co-glycolide), and polyethylene glycol 4000 with the melt-molding technique. The implants were characterized with regards to drug content, morphology, in vitro, and in vivo release profiles. Differential scanning calorimetry (DSC) and Fourier transform infrared spectroscopy (FTIR) were carried out to investigate the physicochemical properties of the implants. Furthermore, the antitumor activity of the implants was tested in a sarcoma 180 mouse model. Results The implants were prepared as solid rods. Scanning electron microscopy images showed a smooth surface of the implant, suggesting that methotrexate was homogeneously dispersed in the polymeric matrix. The results of DSC and FTIR indicated that no significant interaction between methotrexate and the polymer was observed in the implants. Both in vitro and in vivo release profiles of the implants were characterized by burst release followed by sustained release of methotrexate. Intratumoral implantation of methotrexate-loaded implants could efficiently delay tumor growth. Moreover, an increase in the dose of implants led to a higher tumor suppression rate without additional systemic toxicity. Conclusion These results demonstrate that methotrexate-loaded implants had significant antitumor efficacy in a sarcoma 180 mouse model without dose-limiting side effects, and suggest that the implants could be potentially applied as an intratumoral delivery system to treat cancer. PMID:29118572
Palepu, Vivek; Peck, Jonathan H; Simon, David D; Helgeson, Melvin D; Nagaraja, Srinidhi
2017-04-01
OBJECTIVE Lumbar cages with integrated fixation screws offer a low-profile alternative to a standard cage with anterior supplemental fixation. However, the mechanical stability of integrated fixation cages (IFCs) compared with a cage with anterior plate fixation under fatigue loading has not been investigated. The purpose of this study was to compare the biomechanical stability of a screw-based IFC with a standard cage coupled with that of an anterior plate under fatigue loading. METHODS Eighteen functional spinal units were implanted with either a 4-screw IFC or an anterior plate and cage (AP+C) without integrated fixation. Flexibility testing was conducted in flexion-extension (FE), lateral bending (LB), and axial rotation (AR) on intact spines, immediately after device implantation, and post-fatigue up to 20,000 cycles of FE loading. Stability parameters such as range of motion (ROM) and lax zone (LZ) for each loading mode were compared between the 2 constructs at multiple stages of testing. In addition, construct loosening was quantified by subtracting post-instrumentation ROM from post-fatigue ROM. RESULTS IFC and AP+C configurations exhibited similar stability (ROM and LZ) at every stage of testing in FE (p ≥ 0.33) and LB (p ≥ 0.23) motions. In AR, however, IFCs had decreased ROM compared with AP+C constructs at pre-fatigue (p = 0.07) and at all post-fatigue time points (p ≤ 0.05). LZ followed a trend similar to that of ROM in AR. ROM increased toward intact motion during fatigue cycling for AP+C and IFC implants. IFC specimens remained significantly (p < 0.01) more rigid than specimens in the intact condition during fatigue for each loading mode, whereas AP+C construct motion did not differ significantly (p ≥ 0.37) in FE and LB and was significantly greater (p < 0.01) in AR motion compared with intact specimens after fatigue. Weak to moderate correlations (R 2 ≤ 56%) were observed between T-scores and construct loosening, with lower T-scores leading to decreased stability after fatigue testing. CONCLUSIONS These data indicate that a 4-screw IFC design provides fixation similar to that provided by an AP+C construct in FE and LB during fatigue testing and better stability in AR motion.
Szajek, Krzysztof; Wierszycki, Marcin
2016-01-01
Dental implant designing is a complex process which considers many limitations both biological and mechanical in nature. In earlier studies, a complete procedure for improvement of two-component dental implant was proposed. However, the optimization tasks carried out required assumption on representative load case, which raised doubts on optimality for the other load cases. This paper deals with verification of the optimal design in context of fatigue life and its main goal is to answer the question if the assumed load scenario (solely horizontal occlusal load) leads to the design which is also "safe" for oblique occlussal loads regardless the angle from an implant axis. The verification is carried out with series of finite element analyses for wide spectrum of physiologically justified loads. The design of experiment methodology with full factorial technique is utilized. All computations are done in Abaqus suite. The maximal Mises stress and normalized effective stress amplitude for various load cases are discussed and compared with the assumed "safe" limit (equivalent of fatigue life for 5e6 cycles). The obtained results proof that coronial-appical load component should be taken into consideration in the two component dental implant when fatigue life is optimized. However, its influence in the analyzed case is small and does not change the fact that the fatigue life improvement is observed for all components within whole range of analyzed loads.
Early versus delayed loading of mandibular implant-supported overdentures: 5-year results.
Turkyilmaz, Ilser; Tözüm, Tolga F; Tumer, Celal
2010-05-01
Because of poor retention of complete removable dentures for edentulous patients, implant-supported mandibular overdentures have lately become a popular alternative for them. The aims of this prospective study were to evaluate treatment outcomes of mandibular overdentures supported by two unsplinted early-loaded implants and compare these results with those for delayed-loaded implants. A total of 26 edentulous patients were treated with two unsplinted implants supporting a mandibular overdenture. All implants were placed in the canine regions of each mandible according to the one-stage surgical protocol. There were two groups: test group, in which the overdenture was connected 1 week after surgery, and control group, in which the overdenture was connected 3 months after surgery. Standardized clinical and radiographic parameters were recorded at surgery, and after 3, 6, 12, and 18 months, and 2, 3, 4, and 5 years. No implants were lost, and 0.93 +/- 0.3 mm marginal bone resorption was noted for all implants after 5 years. Clinical implant stability measurements, clinical peri-implant parameters, and marginal bone resorptions showed no statistically significant differences between the two groups over 5 years. The results of this prospective clinical study suggest that there is no significant difference in the clinical and radiographic state of patients treated with implant supported mandibular overdentures loaded either 1 week or 3 months after surgery.
Merli, Mauro; Lombardini, Francesco; Esposito, Marco
2010-01-01
To compare the efficacy of two different techniques for vertical bone regeneration at implant placement with particulated autogenous bone at 3 years after loading: resorbable collagen barriers supported by osteosynthesis plates and nonresorbable titanium-reinforced expanded polytetrafluoroethylene barriers. Twenty-two partially edentulous patients requiring vertical bone augmentation were randomly allocated to two treatment groups, each composed of 11 patients. Prosthetic and implant failures, complications, the amount of vertically regenerated bone, and peri-implant marginal bone levels were recorded by independent and blinded assessors. The implant site requiring the most vertical bone regeneration was selected in each patient for bone level assessment. The follow-up time ranged from provisional loading to 3 years after loading. Analysis of covariance and paired t tests were conducted to compare means at the .05 level of significance. No patient dropped out or was excluded at the 3-year follow-up. No prosthetic failures and no implant failures or complications occurred after loading. There was no statistically significant difference in bone loss between the two groups at either 1 year or 3 years. Both groups had gradually lost a statistically significant amount of peri-implant bone at 1 and 3 years (P < .05). After 3 years, patients treated with resorbable barriers had lost a mean of 0.55 mm of bone; patients who had received nonresorbable barriers showed a mean of 0.53 mm of bone loss. Up to 3 years after implant loading, no failures or complications occurred and peri-implant marginal bone loss was minimal. Vertically regenerated bone can be successfully maintained after functional loading.
Ebadian, Behnaz; Farzin, Mahmoud; Talebi, Saeid; Khodaeian, Niloufar
2012-01-01
Background: Available restorative space and bar height is an important factor in stress distribution of implant-supported overdentures. The purpose of this study was to evaluate the effect of different vertical restorative spaces and different bar heights on the stress distribution around implants by 3D finite element analysis. Materials and Methods: 3D finite element models were developed from mandibular overdentures with two implants in the interforaminal region. In these models, four different bar heights from gingival crest (0.5, 1, 1.5, 2 mm) with 15 mm occlusal plane height and three different occlusal plane heights from gingival crest (9, 12, 15 mm) with 2 mm bar height were analyzed. A vertical unilateral and a bilateral load of 150 N were applied to the central occlusal fossa of the first molar and the stress of bone around implant was analyzed by finite element analysis. Results: By increasing vertical restorative space, the maximum stress values around implants were found to be decreased in unilateral loading models but slightly increased in bilateral loading cases. By increasing bar height from gingival crest, the maximum stress values around implants were found to be increased in unilateral loading models but slightly decreased in bilateral loading cases. In unilateral loading models, maximum stress was found in a model with 9 mm occlusal plane height and 1.5 mm bar height (6.254 MPa), but in bilateral loading cases, maximum stress was found in a model with 15 mm occlusal plane height and 0.5 mm bar height (3.482 MPa). Conclusion: The reduction of bar height and increase in the thickness of acrylic resin base in implant-supported overdentures are biomechanically favorable and may result in less stress in periimplant bone. PMID:23559952
Tuzuner, T; Sencan, I; Ozdemir, D; Alper, M; Duman, S; Yavuz, T; Yildirim, M
2006-12-01
The objective of this study was to evaluate the efficacy of teicoplanin- and calcium sulphate-loaded polymethylmethacrylate (PMMA) bone cements in preventing experimental implant-related osteomyelitis in rats. Four groups of antibiotic-loaded rods were prepared and were implanted into the lateral condylus of the rat femur after inoculation of Staphylococcus aureus. The effectiveness of these were assessed microbiologically, radiographically, and histopathologically. Radiographic evaluation revealed a significant reduction of periostal reaction and osteolysis in rats that received calcium sulphate- and teicoplanin-loaded rods. Histopathological evaluation confirmed these results. Acute infection and bone necrosis were found to be significantly lower in rats that had received calcium sulphate- and teicoplanin-loaded rods. The addition of calcium sulfate to teicoplanin-loaded PMMA bone cement appeared satisfactory as an antibiotic-carrying system for prophylaxis of experimental implant-related osteomyelitis, but further investigations are needed to reach definitive statements for clinical applications.
Patel, K; Mardas, N; Donos, N
2013-06-01
The aim of this clinical study was to evaluate the interproximal radiographic bone levels and the survival/success rate of dental implants placed in alveolar ridges previously preserved with a synthetic bone substitute or a bovine xenograft. Alveolar ridge preservation was performed in 27 patients who were randomly assigned in two groups. In the test group (n = 14), the extraction socket was treated with a synthetic bone graft Straumann Bone Ceramic; SBC and a collagen barrier, whereas in the control group (n = 13) a deproteinized bovine bone mineral (DBBM) and the same collagen barrier were used. After 8 months of healing, titanium dental implants with a hydrophilic surface were placed in the preserved ridges. During surgery, 9/13 implants in the SBC group and 8/12 implants in the DBBM group presented with either dehiscence or fenestration defects and required additional bone augmentation. The implants were loaded at 4 months following placement and were followed up for 1 year post-loading. Interproximal radiographic bone levels were evaluated in standardized periapical radiographs at loading and 1 year post-loading. Probing pocket depth, gingival recession and bleeding upon probing were recorded at implants and neighbouring teeth. The success rate of the implants was evaluated according to criteria set by Albrektsson et al. (1986). The survival rate of the implants in both groups was 100% at 1-year post-loading. No statistically significant differences in any of the clinical and radiographic measurements were detected between the two groups (P < 0.05). The success rate of the implants was 84.6% (11/13) in the SBC group and 83.3% (10/12) in the DBBM group. Equivalent success and survival rates (as well as similar radiographic changes) of dental implants placed in alveolar ridges previously preserved with SBC or DBBM should be anticipated. © 2012 John Wiley & Sons A/S.
Khurana, Pardeep; Sharma, Arun; Sodhi, Kiranmeet Kaur
2013-12-01
The aims of this study were to investigate the effect of implant fine threads on crestal bone stress compared to a standard smooth implant collar and to analyze how different abutment diameters influenced the crestal bone stress level. Three-dimensional finite element imaging was used to create a cross-sectional model in SolidWorks 2007 software of an implant (5-mm platform and 10 mm in length) placed in the premolar region of the mandible. The implant model was created to resemble a commercially available fine thread implant. Abutments of different diameters (5.0 mm: standard, 4.5 mm, 4.0 mm, and 3.5 mm) were loaded with a force of 100 N at 90° vertical and 40° oblique angles. Finite element analysis was done in COSMOSWorks software, which was used to analyze the stress patterns in bone, especially in the crestal region. Upon loading, the fine thread implant model had greater stress at the crestal bone adjacent to the implant than the smooth neck implant in both vertical and oblique loading. When the abutment diameter decreased progressively from 5.0 mm to 4.5 mm to 4 mm and to 3.5 mm the thread model showed a reduction of stress at the crestal bone level from 23.2 MPa to 15.02 MPa for fine thread and from 22.7 to 13.5 MPa for smooth collar implant group after vertical loading and from 43.7 MPa to 33.1 MPa in fine thread model and from 36.9 to 20.5 MPa in smooth collar implant model after oblique loading. Fine threads increase crestal stress upon loading. Reduced abutment diameter that is platform switching resulted in less stress translated to the crestal bone in the fine thread and smooth neck.
Finelle, Gary; Lee, Sang J
Digital technology has been widely used in the field of implant dentistry. From a surgical standpoint, computer-guided surgery can be utilized to enhance primary implant stability and to improve the precision of implant placement. From a prosthetic standpoint, computer-aided design/computer-assisted manufacture (CAD/CAM) technology has brought about various restorative options, including the fabrication of customized abutments through a virtual design based on computer-guided surgical planning. This case report describes a novel technique combining the use of a three-dimensional (3D) printed surgical template for the immediate placement of an implant, with CAD/CAM technology to optimize hard and soft tissue healing after bone grafting with the use of a socket sealing abutment.
van Huizum, Martine A; Hage, J Joris; Rutgers, Emiel J; Hoornweg, Marije J
2016-08-01
Local relapse after breast-conserving therapy including whole breast irradiation is typically treated by salvage mastectomy. Immediate reconstruction by pedicled transfer of a latissimus dorsi flap in combination with implantation of a definitive prosthesis or temporary tissue expander following skin sparing salvage mastectomy has been shown to be feasible. However, it has never been shown to be justifiable. The aim of the study was to compare the outcome of this procedure to the widely accepted secondary breast reconstruction by combined latissimus dorsi flap and implant after mastectomy and adjuvant radiotherapy. The surgical outcome of 93 immediate latissimus dorsi and implant reconstructions after skin-sparing salvage mastectomy performed from 2007 to 2011 after radiotherapy was compared to that of 83 secondary reconstructions with the latissimus dorsi and an implant. The follow-up duration was 3.5 years in both groups. Complications were categorized as minor (conservative treatment sufficed) or major (flap loss, mammary skin loss, implant loss, seroma or haematoma indicating repeat surgery). The salvage group scored significantly less on half of the patient-related and procedure-related risk factors. Nevertheless, we observed 27% of short-term major surgical complications and an ultimate success rate of 94% in the salvage group compared to those observed in our series of secondary reconstruction in post-radiation women (27% and 93%, respectively). Skin-sparing salvage mastectomy combined with immediate reconstruction by transfer of a latissimus dorsi flap with an implant is a justifiable reconstructive option for women with a recurrence after irradiation as part of breast-conserving therapy. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Cohen, Omer; Ormianer, Zeev; Tal, Haim; Rothamel, Daniel; Weinreb, Miron; Moses, Ofer
2016-12-01
The objective of this study is to compare bone-to-implant contact (BIC) between implants inserted at high torque due to under-drilling of the crestal bone to those inserted at low torque due to over-drilling of the crestal bone. Forty implants with diameters of 3.75 mm (group A) or 3.55 mm (group B) were inserted in the proximal tibiae of NZW rabbits in two separate surgeries on day 0 or 21. Osteotomy of the crestal bone was finalized with a 3.65-mm drill. In group A, implants were inserted at torque ≥35 Ncm (under-drilling) and in group B with torque <10 Ncm (over-drilling). Implants and their surrounding bone were retrieved on day 42, thus creating 3- and 6-week observation periods, processed for non-decalcified histology and stained with toluidine blue. Crestal BIC (c-BIC) and total BIC (t-BIC) were measured. Wilcoxon test was used to evaluate differences between groups. Three weeks post-surgery, the mean c-BIC in group A was 16.3 ± 3.3 vs 31.5 ± 3.4 % in group B (P < 0.05). At 6 weeks, a similar trend was observed (group A: 28.7 ± 3.6 %; group B: 38.4 ± 4.9 %) (P > 0.05). No differences in t-BIC were noted at 3 weeks and at 6 weeks between the groups. Insertion of implants with an over-drilling protocol of the crestal aspect of the osteotomy resulted in increased short-term crestal bone-to-implant contact. Insertion of implants with a high torque following an under-drilling protocol, commonly used for immediate loading, may reduce crestal bone-to-implant contact at early healing stages.
Choi, Jae-Won; Choi, Kyung-Hee; Chae, Hee-Jin; Chae, Sung-Ki; Bae, Eun-Bin; Lee, Jin-Ju; Lee, So-Hyoun; Jeong, Chang-Mo; Huh, Jung-Bo
2018-04-06
The aim of this study was to introduce the newly developed micro-locking implant prosthetic system and to evaluate the resulting its characteristics. To evaluate load-bearing capacity, 25 implants were divided into five groups: external-hexagon connection (EH), internal-octagon connection (IO), internal-hexagon connection (IH), one-body implant (OB), micro-locking implant system (ML). The maximum compressive load was measured using a universal testing machine (UTM) according to the ISO 14801. Retention was evaluated in two experiments: (1) a tensile test of the structure modifications of the components (attachment and implant) and (2) a tensile test after cyclic loading (total 5,000,000 cycles, 100 N, 2 Hz). The load-bearing capacity of the ML group was not significantly different from the other groups ( p > 0.05). The number of balls in the attachment and the presence of a hexagonal receptacle did not show a significant correlation with retention ( p > 0.05), but the shape of the retentive groove in the implant post had a statistically significant effect on retention ( p < 0.05). On the other hand, the retention loss was observed during the initial 1,000,000 cycles, but an overall constant retention was maintained afterward. Various preclinical studies on this novel micro-locking implant prosthetic system should continue so that it can be applied in clinical practice.
Choi, Kyung-Hee; Chae, Hee-Jin; Chae, Sung-Ki; Bae, Eun-Bin; Lee, Jin-Ju; Lee, So-Hyoun; Jeong, Chang-Mo; Huh, Jung-Bo
2018-01-01
The aim of this study was to introduce the newly developed micro-locking implant prosthetic system and to evaluate the resulting its characteristics. To evaluate load-bearing capacity, 25 implants were divided into five groups: external-hexagon connection (EH), internal-octagon connection (IO), internal-hexagon connection (IH), one-body implant (OB), micro-locking implant system (ML). The maximum compressive load was measured using a universal testing machine (UTM) according to the ISO 14801. Retention was evaluated in two experiments: (1) a tensile test of the structure modifications of the components (attachment and implant) and (2) a tensile test after cyclic loading (total 5,000,000 cycles, 100 N, 2 Hz). The load-bearing capacity of the ML group was not significantly different from the other groups (p > 0.05). The number of balls in the attachment and the presence of a hexagonal receptacle did not show a significant correlation with retention (p > 0.05), but the shape of the retentive groove in the implant post had a statistically significant effect on retention (p < 0.05). On the other hand, the retention loss was observed during the initial 1,000,000 cycles, but an overall constant retention was maintained afterward. Various preclinical studies on this novel micro-locking implant prosthetic system should continue so that it can be applied in clinical practice. PMID:29642407
Open flap versus flapless placement of dental implants. A randomized controlled pilot trial.
Jané-Salas, Enric; Roselló-LLabrés, Xavier; Jané-Pallí, Enric; Mishra, Siddharth; Ayuso-Montero, Raúl; López-López, José
2018-02-20
The aim of this study was to compare the immediate postoperative period of participants rehabilitated with dental implants placed with a conventional technique or with a minimally invasive technique, without a mucoperiosteal flap elevation (flapless). Participants who needed implant placement were divided into two groups: one group was operated using a mucoperiosteal flap elevation (G_A), and the other with a flapless surgical technique (G_B). Objective clinical parameters including oral hygiene, mouth opening, inflammation (facial perimeter), surgical time and analgesic consumption, as well as subjective parameters of pain and degree of satisfaction with the procedure, were evaluated. 48 implants were placed in 30 participants (15 participants per group). Oral hygiene index, maximum interincisal opening, pain and analgesic consumption values had a significant difference between groups favoring the flapless technique at 24 h and 7 days but at the 15 days' follow-up the differences were only significant for oral hygiene and pain (P < 0.05); there were no statistically significant differences between groups in terms of facial perimeter values and surgical time (P > 0.05). Average on the degree of satisfaction was of 2.6 (SD 0.8) for G_A and 3.6 (SD 1.02) for G_B (P = 0.06). One implant placed in G_A (2.0%) failed before prosthetic loading due to mobility and pain at 3 months' follow-up. Participants operated for implant placement with flapless surgical technique go through less postoperative discomfort. Both techniques show high success rates, but to perform a flapless technique patients must be properly selected.
Influence of abutment screw preload on stress distribution in marginal bone.
Khraisat, Ameen
2012-01-01
Changes in an implant assembly after abutment connection might possibly cause deformation in the implant/abutment joint and even in the marginal bone. The aim of this study was to evaluate the influence of abutment screw preload through the implant collar on marginal bone stress without external load application. Models of three implant parts made of titanium (implant, abutment, and abutment screw) and cortical bone were built and positioned with computer-aided design software. Meshing and generation of boundary conditions, loads, and interactions were performed. Each part was meshed independently. The sole load applied to the model was a torque of 32 Ncm on the abutment screw about its axis of rotation. The implant collar was deformed axially after the screw was tightened (3 μm). This deformation resulted in 60 MPa of stress in the marginal bone. Moreover, pressure on the marginal bone in a radial direction was observed. It can be concluded that, without any external load application, abutment screw preload exerts stresses on the implant collar and the marginal bone. These findings should help guide the development of new implant/abutment joint designs that exert less stress on the marginal bone.
Mulcahy, Daniel M.; Esler, Daniel N.
1999-01-01
Radiotelemetry is an essential tool in the study of free-ranging bird populations, and a variety of transmitter-attachment methods have been developed. A promising new method is abdominal implantation of a transmitter with a percutaneous antenna. Researchers using this technique should be concerned about and aware of mortality during surgery and during the immediate postrelease period (the 14-day period following surgery). Of 307 radio-implant surgeries performed between 1995 and 1997 in harlequin ducks (Histrionicus histrionicus), 7 (2.3%) deaths were documented during surgery or anesthetic recovery. Of 295 birds released with implanted radios, 10 (3.4%) died during the immediate postrelease period. Modifications to anesthetic procedures used in the 204 surgeries performed in 1996 and 1997 reduced mortality to 1.5% during surgery and 1.5% during the immediate postrelease period. Anesthetic modifications included intubation of all birds, placement of birds on an elevated platform that allowed the head to rest at a level lower than the body during surgery, placement of a heated water blanket under the birds during surgery, monitoring of body temperature, and use of electrocardiogram and Doppler ultrasound to monitor heart rates and arrhythmias. Low levels of mortality associated with abdominal implantation of radio transmitters may be unavoidable, but mortality can be minimized with adjustments to anesthetic technique.
Precision and Accuracy of a Digital Impression Scanner in Full-Arch Implant Rehabilitation.
Pesce, Paolo; Pera, Francesco; Setti, Paolo; Menini, Maria
To evaluate the accuracy and precision of a digital scanner used to scan four implants positioned according to an immediate loading implant protocol and to assess the accuracy of an aluminum framework fabricated from a digital impression. Five master casts reproducing different edentulous maxillae with four tilted implants were used. Four scan bodies were screwed onto the low-profile abutments, and a digital intraoral scanner was used to perform five digital impressions of each master cast. To assess trueness, a metal framework of the best digital impression was produced with computer-aided design/computer-assisted manufacture (CAD/CAM) technology and passive fit was assessed with the Sheffield test. Gaps between the frameworks and the implant analogs were measured with a stereomicroscope. To assess precision, three-dimensional (3D) point cloud processing software was used to measure the deviations between the five digital impressions of each cast by producing a color map. The deviation values were grouped in three classes, and differences were assessed between class 2 (representing lower discrepancies) and the assembled classes 1 and 3 (representing the higher negative and positive discrepancies, respectively). The frameworks showed a mean gap of < 30 μm (range: 2 to 47 μm). A statistically significant difference was found between the two groups by the 3D point cloud software, with higher frequencies of points in class 2 than in grouped classes 1 and 3 (P < .001). Within the limits of this in vitro study, it appears that a digital impression may represent a reliable method for fabricating full-arch implant frameworks with good passive fit when tilted implants are present.
In vivo and in vitro investigations of a nanostructured coating material – a preclinical study
Adam, Martin; Ganz, Cornelia; Xu, Weiguo; Sarajian, Hamid-Reza; Götz, Werner; Gerber, Thomas
2014-01-01
Immediate loading of dental implants is only possible if a firm bone-implant anchorage at early stages is developed. This implies early and high bone apposition onto the implant surface. A nanostructured coating material based on an osseoinductive bone grafting is investigated in relation to the osseointegration at early stages. The goal is to transmit the structure (silica matrix with embedded hydroxyapatite) and the properties of the bone grafting into a coating material. The bone grafting substitute offers an osseoinductive potential caused by an exchange of the silica matrix in vivo accompanied by vascularization. X-ray diffraction and transmission electron microscopy analysis show that the coating material consists of a high porous silica matrix with embedded nanocrystalline hydroxyapatite with the same morphology as human hydroxyapatite. An in vitro investigation shows the early interaction between coating and human blood. Energy-dispersive X-ray analysis showed that the silica matrix was replaced by an organic matrix within a few minutes. Uncoated and coated titanium implants were inserted into the femora of New Zealand White rabbits. The bone-to-implant contact (BIC) was measured after 2, 4, and 6 weeks. The BIC of the coated implants was increased significantly at 2 and 4 weeks. After 6 weeks, the BIC was decreased to the level of the control group. A histological analysis revealed high bone apposition on the coated implant surface after 2 and 4 weeks. Osteoblastic and osteoclastic activities on the coating material indicated that the coating participates in the bone-remodeling process. The nanostructure of the coating material led to an exchange of the silica matrix by an autologous, organic matrix without delamination of the coating. This is the key issue in understanding initial bone formation on a coated surface. PMID:24627631
Peak insertion torque values of five mini-implant systems under different insertion loads.
Quraishi, Erma; Sherriff, Martyn; Bister, Dirk
2014-06-01
To assess the effect of 1 and 3 kg insertion load on five makes of self-drilling mini-implants on peak insertion torque values to establish risk factors involved in the fracture of mini-implants. Two different loads were applied during insertion of 40 mini-implants from five different manufacturers (Dual Top(™) (1·6×8 mm), Infinitas(™) (1·5×9 mm), Ortho Easy(™) (1·7×8 mm), Spider Screw(™) (1·5×8 mm) and Vector TAS(™) (1·4×8 mm)) into acrylic blocks at 8 rev/min utilizing a Motorized Torque Measurement Stand. Peak insertion torque values for both loads were highest for Vector TAS followed by Ortho Easy and Dual Top and were nearly three times higher than Infinitas (original version) and Spider Screws(TM). The log-rank test showed statistically significant differences for both loads for Vector TAS, Ortho Easy and Spider Screws. Unlike other designs tested, both tapered mini-implant designs (Spider Screw and Infinitas) showed a tendency to buckle in the middle of the body but fractured at the tip. Non-tapered mini-implants fractured at significantly higher torque values compared to tapered designs under both loads. Increased pressure resulted in slightly higher maximum torque values at fracture for some of the mini-implant designs, although this is unlikely to be of clinical relevance. Tripling insertion pressure from 1 to 3 kg increased the risk of bending tapered mini-implants before fracture. © 2014 British Orthodontic Society.
AUNMEUNGTONG, W.; KHONGKHUNTHIAN, P.; RUNGSIYAKULL, P.
2016-01-01
SUMMARY Finite Element Analysis (FEA) has been used for prediction of stress and strain between dental implant components and bone in the implant design process. Purpose Purpose of this study was to characterize and analyze stress and strain distribution occurring in bone and implants and to compare stress and strain of three different implant designs. Materials and methods Three different mini dental implant designs were included in this study: 1. a mini dental implant with an internal implant-abutment connection (MDIi); 2. a mini dental implant with an external implant-abutment connection (MDIe); 3. a single piece mini dental implant (MDIs). All implant designs were scanned using micro-CT scans. The imaging details of the implants were used to simulate models for FEA. An artificial bone volume of 9×9 mm in size was constructed and each implant was placed separately at the center of each bone model. All bone-implant models were simulatively loaded under an axial compressive force of 100 N and a 45-degree force of 100 N loading at the top of the implants using computer software to evaluate stress and strain distribution. Results There was no difference in stress or strain between the three implant designs. The stress and strain occurring in all three mini dental implant designs were mainly localized at the cortical bone around the bone-implant interface. Oblique 45° loading caused increased deformation, magnitude and distribution of stress and strain in all implant models. Conclusions Within the limits of this study, the average stress and strain in bone and implant models with MDIi were similar to those with MDIe and MDIs. The oblique 45° load played an important role in dramatically increased average stress and strain in all bone-implant models. Clinical implications Mini dental implants with external or internal connections have similar stress distribution to single piece mini dental implants. In clinical situations, the three types of mini dental implant should exhibit the same behavior to chewing force. PMID:28042449
Boix, Damien; Gauthier, Olivier; Guicheux, Jérôme; Pilet, Paul; Weiss, Pierre; Grimandi, Gaël; Daculsi, Guy
2004-05-01
The aim of the present study was to assess the efficacy of a ready-to-use injectable bone substitute for bone regeneration around dental implants placed into fresh extraction sockets. Third and fourth mandibular premolars were extracted from three beagle dogs and the interradicular septa were surgically reduced to induce a mesial bone defect. Thereafter, titanium implants were immediately placed. On the left side of the jaw, mesial bone defects were filled with an injectable bone substitute (IBS), obtained by combining a polymer and biphasic calcium phosphate ceramic granules. The right defects were left unfilled as controls. After 3 months of healing, specimens were prepared for histological and histomorphometric evaluations. No post-surgical complications were observed during the healing period. In all experimental conditions, histological observations revealed a lamellar bone formation in contact with the implant. Histomorphometric analysis showed that IBS triggers a significant (P<0.05) increase in terms of the number of threads in contact with bone, bone-to-implant contact, and peri-implant bone density of approximately 8.6%, 11.0%, and 14.7%, respectively. In addition, no significant difference was observed when number of threads, bone-to-implant contact, and bone density in the filled defects were compared to the no-defect sites. It is concluded that an injectable bone substitute composed of a polymeric carrier and calcium phosphate significantly increases bone regeneration around immediately placed implants.
Kohal, Ralf-Joachim; Finke, Hans Christian; Klaus, Gerold
2009-12-01
Zirconia oral implants are a new topic in implant dentistry. So far, no data are available on the biomechanical behavior of two-piece zirconia implants. Therefore, the purpose of this pilot investigation was to test in vitro the fracture strength of two-piece cylindrical zirconia implants after aging in a chewing simulator. This laboratory in vitro investigation comprised three different treatment groups. Each group consisted of 16 specimens. In group 1, two-piece zirconia implants were restored with zirconia crowns (zirconia copings veneered with Triceram; Esprident, Ispringen, Germany), and in group 2 zirconia implants received Empress 2 single crowns (Ivoclar Vivadent AG, Schaan, Liechtenstein). The implants, including the abutments, in the two zirconia groups were identical. In group 3, similar titanium implants were reconstructed with porcelain-fused-to-metal crowns. Eight samples of each group were submitted to artificial aging with a long-term load test in the artificial mouth (chewing simulator). Subsequently, all not artificially aged samples and all artificially aged samples that survived the long-term loading of each group were submitted to a fracture strength test in a universal testing machine. For the pairwise comparisons in the different test groups with or without artificial loading and between the different groups at a given artificial loading condition, the Wilcoxon rank-sum test for independent samples was used. The significance level was set at 5%. One sample of group 1 (veneer fracture), none of group 2, and six samples of group 3 (implant abutment screw fractures) failed while exposed to the artificial mouth. The values for the fracture strength after artificial loading with 1.2 million cycles for group 1 were between 45 and 377 N (mean: 275.7 N), in group 2 between 240 and 314 N (mean: 280.7 N), and in the titanium group between 45 and 582 N (mean: 165.7 N). The fracture strength results without artificial load for group 1 amounted to between 270 and 393 N (mean: 325.1 N), for group 2 between 235 and 321 N (mean: 281.8 N), and between 474 and 765 N (mean: 595.2 N) for the titanium group. The failure mode during the fracture testing in the zirconia implant groups was a fracture of the implant head and a bending/fracture of the abutment screw in the titanium group. Within the limits of this pilot investigation, the biomechanical stability of all tested prototype implant groups seems to be - compared with the possibly exerted occlusal forces - borderline for clinical use. A high number of failures occurred already during the artificial loading in the titanium group at the abutment screw level. The zirconia implant groups showed irreparable implant head fractures at relatively low fracture loads. Therefore, the clinical use of the presented prototype implants has to be questioned.
NASA Astrophysics Data System (ADS)
Moutos, Franklin T.; Freed, Lisa E.; Guilak, Farshid
2007-02-01
Tissue engineering seeks to repair or regenerate tissues through combinations of implanted cells, biomaterial scaffolds and biologically active molecules. The rapid restoration of tissue biomechanical function remains an important challenge, emphasizing the need to replicate structural and mechanical properties using novel scaffold designs. Here we present a microscale 3D weaving technique to generate anisotropic 3D woven structures as the basis for novel composite scaffolds that are consolidated with a chondrocyte-hydrogel mixture into cartilage tissue constructs. Composite scaffolds show mechanical properties of the same order of magnitude as values for native articular cartilage, as measured by compressive, tensile and shear testing. Moreover, our findings showed that porous composite scaffolds could be engineered with initial properties that reproduce the anisotropy, viscoelasticity and tension-compression nonlinearity of native articular cartilage. Such scaffolds uniquely combine the potential for load-bearing immediately after implantation in vivo with biological support for cell-based tissue regeneration without requiring cultivation in vitro.
Merıç, Gökçe; Erkmen, Erkan; Kurt, Ahmet; Eser, Atilim; özden, Ahmet Utku
2011-11-01
The purpose of the study was to compare the effects of two distinct collar geometries of implants on stress distribution in the bone around the implants supporting cantilever fixed partial dentures (CFPDs) as well as in the implant-abutment complex and superstructures. The three-dimensional finite element method was selected to evaluate the stress distribution. CFPDs which was supported by microthread collar structured (MCS) and non-microthread collar structured (NMCS) implants was modeled; 300 N vertical, 150 N oblique and 60 N horizontal forces were applied to the models separately. The stress values in the bone, implant-abutment complex and superstructures were calculated. In the MCS model, higher stresses were located in the cortical bone and implant-abutment complex in the case of vertical load while decreased stresses in cortical bone and implant-abutment complex were noted within horizontal and oblique loading. In the case of vertical load, decreased stresses have been noted in cancellous bone and framework. Upon horizontal and oblique loading, a MCS model had higher stress in cancellous bone and framework than the NMCS model. Higher von Mises stresses have been noted in veneering material for NMCS models. It has been concluded that stress distribution in implant-supported CFPDs correlated with the macro design of the implant collar and the direction of applied force.
Goto, Takaharu; Nagao, Kan; Ishida, Yuichi; Tomotake, Yoritoki; Ichikawa, Tetsuo
2015-02-01
This in vitro study investigated the effect of attachment installation conditions on the load transfer and denture movements of implant overdentures, and aims to clarify the differences among the three types of attachments, namely ball, Locator, and magnet attachments. Three types of attachments, namely ball, Locator, and magnetic attachments were used. An acrylic resin mandibular edentulous model with two implants placed in the bilateral canine regions and removable overdenture were prepared. The two implants and bilateral molar ridges were connected to three-axis load-cell transducers, and a universal testing machine was used to apply a 50 N vertical force to each site of the occlusal table in the first molar region. The denture movement was measured using a G(2) motion sensor. Three installation conditions, namely, the application of 0, 50, and 100 N loads were used to install each attachment on the denture base. The load transfer and denture movement were then evaluated. The resultant force decreased with increasing installation load for all attachments. In particular, the resultant force on implants on the loading side of the Locator attachment significantly decreased when the installation load was increased from 0 to 50 N, and that for magnetic attachment significantly decreased when the installation load was increased from 50 to 100 N. For the residual ridges on the loading side, the direction of the forces for all attachments changed to downward with increasing installation load. Furthermore, the yaw Euler angle increased with increasing installation load for the magnetic attachment. Subject to the limitations of this study, the use of any installation load greater than 0 N is recommended for the installation of ball and Locator attachments on a denture base. Regarding magnetic attachments, our results also recommend installation on a denture base using any installation load greater than 0 N, and suggest that the resultant force acting on the implant can be decreased by increasing the installation load; however, a large installation load of 100 N should be avoided when installing the attachment on the denture base to avoid increasing the denture movement. © 2014 by the American College of Prosthodontists.
Mechanical Properties of Abutments: Resin-Bonded Glass Fiber-Reinforced Versus Titanium.
Bassi, Mirko Andreasi; Bedini, Rosells; Pecci, Raffaela; Ioppolo, Pietro; Laritano, Dorina; Carinci, Francesco
2016-01-01
The clinical success and longevity of endosseous implants, after their prosthetic finalization, mainly depends on mechanical factors. Excessive mechanical stress has been shown to cause initial bone loss around implants in the presence of a rigid implant-prosthetic connection. The implant abutments are manufactured with high elastic modulus materials such as titanium, steel, precious alloys, or esthetic ceramics. These materials do not absorb any type of shock from the chewing loads or ensure protection of the bone-implant interface, especially when the esthetic restorative material is ceramic rather than composite resin. The mechanical resistance to cyclical load was evaluated in a tooth-colored fiber-reinforced abutment prototype (TCFRA) and compared to that of a similarly shaped titanium abutment (TA). Eight TCFRAs and eight TAs were adhesively cemented on as many titanium implants. The swinging the two types of abutments showed during the application of sinusoidal load was also analyzed. In the TA group, fracture and deformation occurred in 12.5% of samples, while debonding occurred in 62.5%. In the TCFRA group, only debonding was present, in 37.5% of samples. In comparison to the TAs, the TCFRAs exhibited greater swinging during the application of sinusoidal load. In the TA group extrusion prevailed, whereas in the TCFRA group intrusion was more frequent. TCFRA demonstrated a greater elasticity than did TAs to the flexural load, absorbing part of the transversal load applied on the fixture during the chewing function and thus reducing the stress on the bone-implant interface.
Thompson, D E; Agrawal, C M; Athanasiou, K
1996-01-01
Biodegradable implants that release growth factors or other bioactive agents in a controlled manner are investigated to enhance the repair of musculoskeletal tissues. In this study, the in vitro release characteristics and mechanical properties of a 50:50 polylactic acid/polyglycolic acid two phase implant were examined over a 6-week period under no-load conditions or under a cyclic compressive load, such as that experienced when walking slowly during rehabilitation. The results demonstrated that a cyclic compressive load significantly slows the decrease of molecular chain size during the first week, significantly increases protein release for the first 2-3 weeks, and significantly stiffens the implant for the first 3 weeks. It was also shown that protein release is initially high and steadily decreases with time until the molecular weight declines to about 20% of its original value (approximately 4 weeks). Once this threshold is reached, increased protein release, surface deformation, and mass loss occurs. This study also showed that dynamic loading and the environment in which an implant is placed affect its biodegradation. Therefore, it may be essential that in vitro degradation studies of these or similar implants include a dynamic functional environment.
Numerical optimization of composite hip endoprostheses under different loading conditions
NASA Technical Reports Server (NTRS)
Blake, T. A.; Davy, D. T.; Saravanos, D. A.; Hopkins, D. A.
1992-01-01
The optimization of composite hip implants was investigated. Emphasis was placed on the effect of shape and material tailoring of the implant to improve the implant-bone interaction. A variety of loading conditions were investigated to better understand the relationship between loading and optimization outcome. Comparisons of the initial and optimal models with more complex 3D finite element models were performed. The results indicate that design improvements made using this method result in similar improvements in the 3D models. Although the optimization outcomes were significantly affected by the choice of loading conditions, certain trends were observed that were independent of the applied loading.
Schouman, T; Schmitt, M; Adam, C; Dubois, G; Rouch, P
2016-06-01
The aim of this work was to assess the influence of reduction of the apparent mechanical properties of fully load-bearing porous titanium implants used in mandibular bone defects. Segmental 18mm long bone defects were created bilaterally in the lower jaws of adult ewes. One group of 6 ewes (group A) was treated with load-bearing 'rigid' (high stiffness) porous implants on the right side, and with control on the left side. A second group of 6 ewes (group B) was treated with 'flexible' porous and control implants exhibiting apparent mechanical properties ten times lower than the rigid implants. The mechanical behavior of the reconstructed hemi-mandibles was assessed by cantilever testing and bone ingrowth into the segmental defects was assessed by BV/TV measurement within the implant using micro-CT 12 weeks after implantation. A significantly higher rigidity was identified for porous implants compared with control implants at the anterior interface in group B. BV/TV of porous implants was significantly higher than that of control implants in group A. BV/TV differences were significant between porous and control implants in group B and were homogeneous along the main axis. Significantly higher BV/TV was identified in most sub-volumes of group B porous implants compared with group A. This work highlights the critical importance of the tuning of scaffolds to promote bone ingrowth with reference to the local strains occurring within the porous scaffold, which in this application was achieved using fully load-bearing low-stiffness porous titanium implants. Copyright © 2016 Elsevier Ltd. All rights reserved.
Pellicer-Chover, Hilario; Peñarrocha-Diago, María; Peñarrocha-Oltra, David; Gomar-Vercher, Sonia; Agustín-Panadero, Rubén
2016-01-01
Background To assess the influence of the crestal or subcrestal placement of implants upon peri-implant bone loss over 12 months of follow-up. Material and Methods Twenty-six patients with a single hopeless tooth were recruited in the Oral Surgery Unit (Valencia University, Valencia, Spain). The patients were randomized into two treatment groups: group A (implants placed at crestal level) or group B (implants placed at subcrestal level). Control visits were conducted by a trained clinician at the time of implant placement and 12 months after loading. A previously established standard protocol was used to compile general data on all patients (sex and age, implant length and diameter, and brushing frequency). Implant success rate, peri-implant bone loss and the treatment of the exposed implant surface were studied. The level of statistical significance was defined as 5% (α=0.05). Results Twenty-three patients (8 males and 15 females, mean age 49.8±11.6 years, range 28-75 years) were included in the final data analyses, while three were excluded. All the included subjects were nonsmokers with a brushing frequency of up to twice a day in 85.7% of the cases. The 23 implants comprised 10 crestal implants and 13 subcrestal implants. After implant placement, the mean bone position with respect to the implant platform in group A was 0.0 mm versus 2.16±0.88 mm in group B. After 12 months of follow-up, the mean bone positions were -0.06±1.11 mm and 0.95±1.50 mm, respectively - this representing a bone loss of 0.06±1.11 mm in the case of the crestal implants and of 1.22±1.06 mm in the case of the subcrestal implants (p=0.014). Four crestal implants and 5 subcrestal implants presented peri-implant bone levels below the platform, leaving a mean exposed treated surface of 1.13 mm and 0.57 mm, respectively. The implant osseointegration success rate at 12 months was 100% in both groups. Conclusions Within the limitations of this study, bone loss was found to be greater in the case of the subcrestal implants, though from the clinical perspective these implants presented bone levels above the implant platform after 12 months of follow-up. Key words:Immediate implants, tooth extraction, dental implants, single-tooth, crestal bone, placement level. PMID:26615504
Bone microstrain values of 1-piece and 2-piece implants subjected to mechanical loading.
Harel, Noga; Eshkol-Yogev, Inbar; Piek, Dana; Livne, Shiri; Lavi, David; Ormianer, Zeev
2013-06-01
The purpose of this study was to measure and compare the strain levels in peri-implant bone as generated by 1-piece (1P) and 2-piece (2P) implant systems. The implants (1P and 2P) were placed into bovine bone according to the manufacturer's protocol. Four linear strain gauges were placed around each implant neck and apex. Each model was loaded in static loading by a material testing machine in ascending forces ranging from 20 to 120 N. Microstrains (μ[Latin Small Letter Open E]) generated in the surrounding bone were measured by a strain gauge and recorded. Recorded microstrains were significantly higher for 1P implants than for 2P implants. Average recorded microstrain values were significantly lower in the neck (71.6 and 17.3 µs) compared with the apical (132 and 60 µs) regions of 1P and 2P implants, respectively (P < 0.0001). Within the limitations of this study, highest microstrains were generated in apical regions regardless of implant design, but the 2P implant ap-peared to provide a stress-damping effect in both the cervical and apical regions compared with the 1P implant.
Imunohistological aspects of the tissue around dental implants
NASA Astrophysics Data System (ADS)
Nimigean, Victor; Nimigean, Vanda R.; Sǎlǎvǎstru, Dan I.; Moraru, Simona; BuÅ£incu, Lavinia; Ivaşcu, Roxana V.; Poll, Alexandru
2016-03-01
Objectives: study of soft and hard tissues around implants. Material and methods: For the immunohistochemical and histological study of the implant/soft tissue interface, we examined pieces of peri-implant mucosa harvested from 35 patients. The implant/bone interface was assessed using histologic and histomorphometric examination of hard tissues around unloaded, early loaded or delayed loaded dental implants with pre-established design, with a sandblasted and acid-etched surface, placed both in extraction sockets, or after bone healing following tooth removal. This study was performed on 9 common race dogs. Results: The histological study of the implant/soft tissue interface showed regenerative modifications and moderate chronic subepithelial inflammatory reactions. Immunohistochemical evaluation of the soft tissue biopsies revealed the presence of specific immunocompetent cells and proteins of the matrix metalloproteinase (MMP) expression. Bone-implants contacts were more obvious in the apical half of the implants and at the edges of the threads, than between them. A mature, lamelliform bone containing lacunae with osteocytes and lack of connective tissue were noticed around implants that were late placed and loaded. The new-formed bone was also abundant in the crestal zone, not only in the apical part of the implants. Conclusions: A thorough understanding of the microstructure of dental implant/soft and hard tissue interface will improve the longevity of osseointegrated implants.
Divac, Marija; Stawarczyk, Bogna; Sahrmann, Philipp; Attin, Thomas; Schmidlin, Patrick R
2013-01-01
To assess the primary stability of a hybrid self-tapping implant and a cylindric non-self-tapping implant in an in vitro test model using polyurethane foam. Eighty standardized blocks of cellular rigid polyurethane foam, 2 cm long and 1 cm wide, with different thicknesses of 2, 4, 6, and 9 mm (n = 10 per group) were cut. Two implant systems--a hybrid self-tapping (Tapered Effect [TE], Straumann) and a cylindric non-self-tapping (Standard Plus [SP] Wide Neck, Straumann) were placed in the block specimens. Subsequently, resonance frequency analysis (RFA) was performed. The RFA measurements were made in triplicate on four aspects of each implant (mesial, distal, buccal, and oral), and the mean RFA value was calculated. Subsequently, the tensile load of the implants was determined by pull-out tests. The data were analyzed using one-way and two-way analysis of variance followed by a post hoc Scheffe test and a t test (α = .05). Additionally, the simple linear correlation between the RFA and tensile load values was evaluated. No statistically significant differences were found between TE and SP in terms of RFA at different bone thicknesses. Starting from a bone thickness of 4 mm, TE implants showed significantly higher tensile load compared to SP implants (P = .016 to .040). A correlation was found between the RFA measurements and tensile load. Mechanically stable placement is possible with TE and SP implants in a trabecular bone model. RFA and tensile load increased with greater bone thickness.
Bulaqi, Haddad Arabi; Mousavi Mashhadi, Mahmoud; Safari, Hamed; Samandari, Mohammad Mahdi; Geramipanah, Farideh
2015-06-01
Implants in posterior regions of the jaw require short dental implants with long crown heights, leading to increased crown-to-implant ratios and mechanical stress. This can lead to fracture and screw loosening. The purpose of this study was to investigate the dynamic nature and behavior of prosthetic components and preimplant bone and evaluate the effect of increased crown height space (CHS) and crown-to-implant ratio on stress concentrations under external oblique forces. The severely resorbed bone of a posterior mandible site was modeled with Mimics and Catia software. A second mandibular premolar tooth was modeled with CHS values of 8.8, 11.2, 13.6, and 16 mm. A Straumann implant (4.1×8 mm), a directly attached crown, and an abutment screw were modeled with geometric data and designed by using SolidWorks software. Abaqus software was used for the dynamic simulation of screw tightening and the application of an external load to the buccal cusp at a 75.8-degree angle with the occlusal plane. The distribution of screw load and member load at each step was compared, and the stress values were calculated within the dental implant complex and surrounding bone. During tightening, the magnitude and distribution of the preload and clamp load were uniform and equal at the cross section of all CHSs. Under an external load, the screw load decreased and member load increased. An increase in the CHS caused the corresponding distribution to become more nonuniform and increased the maximum compressive and tensile stresses in the preimplant bone. Additionally, the von Mises stress decreased at the abutment screw and increased at the abutment and fixture. Under nonaxial forces, increased CHS does not influence the decrease in screw load or increase in member load. However, it contributes to screw loosening and fatigue fracture by skewing the stress distribution to the transverse section of the implant. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Effect of plastic-covered ultrasonic scalers on titanium implant surfaces.
Mann, M; Parmar, D; Walmsley, A D; Lea, S C
2012-01-01
Maintaining oral health around titanium implants is essential. The formation of a biofilm on the titanium surface will influence the continuing success of the implant. These concerns have led to modified ultrasonic scaler instruments that look to reduce implant damage while maximising the cleaning effect. This study aimed to assess the effect of instrumentation, with traditional and modified ultrasonic scalers, on titanium implant surfaces and to correlate this with the oscillations of the instruments. Two ultrasonic insert designs (metallic TFI-10 and a plastic-tipped implant insert) were selected. Each scaler probe was scanned using a scanning laser vibrometer, under loaded and unloaded conditions, to determine their oscillation characteristics. Loads were applied against a titanium implant (100g and 200 g) for 10 s. The resulting implant surfaces were then scanned using laser profilometry and scanning electron microscopy (SEM). Insert probes oscillated with an elliptical motion with the maximum amplitude at the probe tip. Laser profilometry detected defects in the titanium surface only for the metallic scaler insert. Defect widths at 200 g high power were significantly larger than all other load/power conditions (P<0.02). Using SEM, it was observed that modifications to the implant surface had occurred following instrumentation with the plastic-tipped insert. Debris was also visible around the defects. Metal scalers produce defects in titanium implant surfaces and load and power are important factors in the damage caused. Plastic-coated scaler probes cause minimal damage to implant surfaces and have a polishing action but can leave plastic deposits behind on the implant surface. © 2011 John Wiley & Sons A/S.
Kato, Hatsumi; Kuroshima, Shinichiro; Inaba, Nao; Uto, Yusuke; Sawase, Takashi
2018-02-01
The aim of this study was to clarify whether marginal grooves on dental implants affect osseointegration, bone structure, and the alignment of collagen fibers to determine bone quality under loaded conditions. Anodized Ti-6Al-4V alloy dental implants, with and without marginal grooves (test and control implants, respectively), were used (3.7 × 8.0 mm). Fourth premolars and first molars of 6 beagle mandibles were extracted. Two control and test implants were placed in randomly selected healed sites at 12 weeks after tooth extraction. Screw-retained single crowns for first molars were fabricated. Euthanasia was performed at 8 weeks after the application of occlusal forces. Implant marginal bone level, bone to implant contact (BIC), bone structure around dental implants, and the alignment of collagen fibers determining bone quality were analyzed. The marginal bone level in test implants was significantly higher than that in control implants. Occlusal forces significantly increased BIC in test implants ( P = .007), whereas BIC did not change in control implants, irrespective of occlusal forces ( P = .303). Moreover, occlusal forces significantly increased BIC in test implants compared with control implants ( P = .032). Additionally, occlusal forces preferentially aligned collagen fibers in test implants, but not control implants. Hence, marginal grooves on dental implants have positive effects on increased osseointegration and adapted bone quality based on the preferential alignment of collagen fibers around dental implants under loaded conditions.
Yoon, Kyung-Ho; Kim, Su-Gwan; Lee, Jeong-Hoon; Suh, Seung-Woo
2011-10-01
The effect of stress levels and distributions around the internal nonsubmerged type implants after vertical bone resorption was investigated in this study. An HSII implant was placed in 4 cylindrical alveolar bone models with differing degrees of thread exposures. The load applied to each implant was von Mises stress and principal stress, 250 N in axial direction and 30 degrees lateral pressure. The difference in the load between the bone and the connective portion of the implant was obtained using ANSYS analysis. Bone loss in the cervical area of the implant was more obvious under lateral pressure. When more threads were exposed, bone level decreased and the maximum load applied on the fixture increased. It was concluded that higher bone level has a biomechanical advantage with respect to stress concentration.
Sanz-Martín, Ignacio; Sanz-Sánchez, Ignacio; Noguerol, Fernando; Cok, Susy; Ortiz-Vigón, Alberto; Sanz, Mariano
2017-06-01
Peri-implant bone levels can vary according to the implant neck macro-design and the implant-abutment interface. To compare the changes in soft and hard tissues when using a one-piece implant with a machined collar (TG) versus a two-piece implant with a progressive platform widening and a platform switching connection (SP). Partially edentulous patients willing to receive one or two implants in the posterior maxilla or mandible were randomized to the control (TG) or to the test group (SP). Final prostheses were delivered after 12 months. Radiographic measurements of interproximal bone levels (primary outcome) were assessed at implant loading and 1-year postloading. Clinical, patient related outcomes and adverse events were assessed at loading and after 6 and 12 months. Sixty-one implants were placed in 47 patients, 37 patients (18 in the TG group and 19 in the SP group), and 47 implants (23 TG and 24 SP) completed the 24-months follow up. At the patient level, a significantly greater bone resorption from baseline to implant loading was observed in the SP group (-0.42 ± 0.45 vs -0.07 ± 0.45; P = .001*), while from loading to the final visit, the TG group had significantly greater bone loss than the SP group (-0.26 ± 0.22 vs -0.11 ± 0.2; P = .020*). At 24 months after surgery, there were no significant differences between both groups (control: 0.33 ± 0.49 vs test: 0.53 ± 0.53; P = .230). Similarly, no significant differences were observed for the secondary outcomes. Both types of implant reported high survival rates and similar bone level changes, clinical parameters, and patient related outcomes after 12 months of loading. © 2017 Wiley Periodicals, Inc.
The Dermal Apron Technique for Immediate Implant Socket Management: A Novel Technique.
Levin, Barry P
2016-01-01
With immediate implant placement and provisionalization (IIP) in the esthetic zone, measures to counter hard and soft tissue loss are frequently necessary. To reduce the morbidity associated with bone and connective tissue procurement, various exogenous materials are utilized. The "Dermal Apron Technique" presented in this article demonstrates the use of a composite bone particulate (allograft/xenograft) plus a dermal allograft, adapted around screw-retained temporary crowns and secured within a subperiosteal pouch. The purpose is to augment the thickness of peri-implant mucosa for the purpose of preserving ridge dimensions and preventing mucosal recession. Controlled studies are required to further support its use. Clinical significance: Soft tissue health and harmony are critical for successful implant therapy in the esthetic regions of the dentition. Often, autogenous soft tissue grafts are used to augment peri-implant soft tissues. The Dermal Apron Technique is a method, that in specific situations, obviates the need for autogenous grafting. This reduces treatment time and morbidity associated with procurement of these grafts. The Dermal Apron Technique is used simultaneous with immediate placement and provisionalization and can improve long-term esthetic outcomes for patients. © 2016 Wiley Periodicals, Inc.
Solberg, K; Heinemann, F; Pellikaan, P; Keilig, L; Stark, H; Bourauel, C; Hasan, I
2017-05-01
The effect of implants' number on overdenture stability and stress distribution in edentulous mandible, implants and overdenture was numerically investigated for implant-supported overdentures. Three models were constructed. Overdentures were connected to implants by means of ball head abutments and rubber ring. In model 1, the overdenture was retained by two conventional implants; in model 2, by four conventional implants; and in model 3, by five mini implants. The overdenture was subjected to a symmetrical load at an angle of 20 degrees to the overdenture at the canine regions and vertically at the first molars. Four different loading conditions with two total forces (120, 300 N) were considered for the numerical analysis. The overdenture displacement was about 2.2 times higher when five mini implants were used rather than four conventional implants. The lowest stress in bone bed was observed with four conventional implants. Stresses in bone were reduced by 61% in model 2 and by 6% in model 3 in comparison to model 1. The highest stress was observed with five mini implants. Stresses in implants were reduced by 76% in model 2 and 89% increased in model 3 compared to model 1. The highest implant displacement was observed with five mini implants. Implant displacements were reduced by 29% in model 2, and increased by 273% in model 3 compared to model 1. Conventional implants proved better stability for overdenture than mini implants. Regardless the type and number of implants, the stress within the bone and implants are below the critical limits.
Effect of a freeze-dried CMC/PLGA microsphere matrix of rhBMP-2 on bone healing.
Schrier, J A; Fink, B F; Rodgers, J B; Vasconez, H C; DeLuca, P P
2001-10-07
The hypothesis of this research was that implants of poly(lactide-co-glycolide) (PLGA) microspheres loaded with bone morphogenetic protein-2 (rhBMP-2) and distributed in a freeze-dried carboxymethylcellulose (CMC) matrix would produce more new bone than would matrix implants of non-protein-loaded microspheres or matrix implants of only CMC. To test this hypothesis it was necessary to fashion microsphere-loaded CMC implants that were simple to insert, fit precisely into a defect, and would not elicit swelling. Microspheres were produced via a water-in-oil-in-water double-emulsion system and were loaded with rhBMP-2 by soaking them in a buffered solution of the protein at a concentration of 5.4 mg protein per gram of PLGA. Following recovery of the loaded microspheres by lyophilization, matrices for implantation were prepared by lyophilizing a suspension of the microspheres in 2% CMC in flat-bottom tissue culture plates. Similar matrices were made with 2% CMC and with 2% CMC containing blank microspheres. A full-thickness calvarial defect model in New Zealand white rabbits was used to assess bone growth. Implants fit the defect well, allowing for direct application. Six weeks postsurgery, defects were collected and processed for undecalcified histology. In vitro, 60% of the loaded rhBMP-2 released from devices or microspheres in 5 to 7 days, with the unembedded microspheres releasing faster than those embedded in CMC. In vivo, the rhBMP-2 microspheres greatly enhanced bone healing, whereas nonloaded PLGA microspheres in the CMC implants had little effect. The results showed that a lyophilized device of rhBMP-2/PLGA microspheres in CMC was an effective implantable protein-delivery system for use in bone repair.
Setia, Gaurav; Yousef, Hoda; Ehrenberg, David; Luke, Allyn; Weiner, Saul
2013-08-01
The purpose of this study was to use an in vitro model system to compare the effects on the screw torque and screw dimensions within 2 commercially available implant systems from occlusal loading on a cantilevered-fixed partial denture. Cantilevered implant-supported 3-unit prostheses with 2 premolar abutments and 1 premolar pontic (7.3 mm in length) were made on resin casts containing 2 implant analogs for 2 implant systems: BioLok Silhouette Tapered Implant System (Birmingham, AL) and Zimmer Tapered Screw-Vent Implant System (Carlsbad, CA) with 10 samples in each group. Each sample was loaded with either of 2 protocols: (1) a load of 50 N on the cantilevered pontic unit and (2) a loading of 150 N on all 3 units. The outcome measures were (1) changes in residual torque of the abutment screws and (2) changes in screw dimension. The BioLok Silhouette Tapered Implant group demonstrated slight but statistically significant torque loss 18.8% to 28.5% in both abutment screws for both protocols, P ≤ 0.05, without any changes in screw dimension. In the Zimmer Tapered Screw-Vent Implant group, there was a significant elongation of the abutment screws and a markedly significant 44.4%, (P ≤ 0.01) loss in torque in the mesial screw and a 28.5%, (P ≤ 0.05) loss in torque in the distal screw when the cantilever alone was loaded. Differences in screw design influence the maintenance of preload and distortion of the shank. The influence of the interface design, namely an internal hex of 1 mm versus an external hex did not influence the preload. Cantilevered prostheses can cause loss of torque and dimensional changes in abutment screws.
Tomaszewski, P. K.; Verdonschot, N.; Bulstra, S. K.
2010-01-01
An alternative solution to conventional stump–socket prosthetic limb attachment is offered by direct skeletal fixation. This study aimed to assess two percutaneous trans-femoral implants, the OPRA system (Integrum AB, Göteborg, Sweden), and the ISP Endo/Exo prosthesis (ESKA Implants AG, Lübeck, Germany) on bone failure and stem–bone interface mechanics both early post-operative (before bony ingrowth) and after full bone ingrowth. Moreover, mechanical consequences of implantation of those implants in terms of changed loading pattern within the bone and potential consequences on long-term bone remodeling were studied using finite-element models that represent the intact femur and implants fitted in amputated femora. Two experimentally measured loads from the normal walking cycle were applied. The analyses revealed that implantation of percutaneous prostheses had considerable effects on stress and strain energy density levels in bone. This was not only caused by the implant itself, but also by changed loading conditions in the amputated leg. The ISP design promoted slightly more physiological strain energy distribution (favoring long-term bone maintenance), but the OPRA design generated lower bone stresses (reducing bone fracture risk). The safety factor against mechanical failure of the two percutaneous designs was relatively low, which could be improved by design optimization of the implants. PMID:20309731
Does Ferrule Effect Affect Implant-Abutment Stability?
Mohajerfar, Maryam; Beyabanaki, Elaheh; Geramy, Allahyar; Siadat, Hakimeh; Alikhasi, Marzieh
2016-12-01
This study investigated the influence of placing implant-supported crowns on the torque loss of the abutment screw before and after loading. Twenty implant-abutment assemblies were randomly assigned to two groups. The first group was consisted of abutments with abutment-level finishing line (abutment-level), and in the second group the crown margin was placed on the implant shoulder (implant-level). Initial torque loss was recorded for all specimens. After 500000 cyclic load of 75 N and frequency of 2 Hz, post loading torque loss was recorded. Finite element model of each group was also modeled and screw energy, and stress were analyzed and compared between two groups. ANOVA for repeated measurements showed that the torque loss did not change significantly after cyclic loading (P=0.73). Crown margin also had no significant effect on the torque loss (P=0.56). However, the energy and stress of screw in abutment-level model (4.49 mJ and 22.74 MPa) was higher than implant-level model (3.52 mJ and 20.81 MPa). Although embracing the implant with crown produced less stress and energy in the abutment-implant screw, it did not have any significant influence on the torque loss of the screw. Copyright© 2016 Dennis Barber Ltd
In situ microradioscopy and microtomography of fatigue-loaded dental two-piece implants.
Wiest, Wolfram; Zabler, Simon; Rack, Alexander; Fella, Christian; Balles, Andreas; Nelson, Katja; Schmelzeisen, Rainer; Hanke, Randolf
2015-11-01
Synchrotron real-time radioscopy and in situ microtomography are the only techniques providing direct visible information on a micrometre scale of local deformation in the implant-abutment connection (IAC) during and after cyclic loading. The microgap formation at the IAC has been subject to a number of studies as it has been proposed to be associated with long-term implant success. The next step in this scientific development is to focus on the in situ fatigue procedure of two-component dental implants. Therefore, an apparatus has been developed which is optimized for the in situ fatigue analysis of dental implants. This report demonstrates both the capability of in situ radioscopy and microtomography at the ID19 beamline for the study of cyclic deformation in dental implants. The first results show that it is possible to visualize fatigue loading of dental implants in real-time radioscopy in addition to the in situ fatigue tomography. For the latter, in situ microtomography is applied during the cyclic loading cycles in order to visualize the opening of the IAC microgap. These results concur with previous ex situ studies on similar systems. The setup allows for easily increasing the bending force, to simulate different chewing situations, and is, therefore, a versatile tool for examining the fatigue processes of dental implants and possibly other specimens.
The long term effect of an iris-supported lens on the endothelium.
Galin, M A; Dotson, R S; Obstbaum, S A; Tuberville, A W
1982-01-01
A retrospective study of 104 eyes that had iris-supported Sputnik intraocular lenses implanted and no surgery in the fellow eye and a separate series of 30 implanted eyes whose second eyes underwent surgery but did not receive implants disclosed that endothelial cell densities in the eyes with implants decreased immediately after surgery and then continued to decrease at the same rate as those of the control eyes. There was no sudden decrease in the endothelial cell counts during follow-up periods ranging from three to seven years. The main cause of large cell losses immediately after surgery, and possibly long-term corneal decompensation, was surgical manipulation rather than the presence of this style of intraocular lens.
COMMUNICATION: Drug loading of nanoporous TiO2 films
NASA Astrophysics Data System (ADS)
Ayon, Arturo A.; Cantu, Michael; Chava, Kalpana; Mauli Agrawal, C.; Feldman, Marc D.; Johnson, Dave; Patel, Devang; Marton, Denes; Shi, Emily
2006-12-01
The loading of therapeutic amounts of drug on a nanoporous TiO2 surface is described. This novel drug-loading scheme on a biocompatible surface, when employed on medical implants, will benefit patients who require the deployment of drug-eluting implants. Anticoagulants, analgesics and antibiotics can be considered on the associated implants for drug delivery during the time of maximal pain or risk for patients undergoing orthopedic procedures. Therefore, this scheme will maximize the chances of patient recovery.
Holst, Alexandra Ioana; Karl, Matthias; Karolczak, Marek; Goellner, Matthias; Holst, Stefan
2010-01-01
Primary stability and micromovement of orthodontic mini-implants depends on a number of factors and influences clinical success or failure. The purpose of this study was to assess the behavior of orthodontic mini-implants upon initial load application. Orthodontic mini-implants (n = 39) were inserted in the alveolar process of maxillary human cadaver specimens (n = 10). Increasing horizontal forces (up to 2.5 N) were applied, and triggered images were taken in 0.5-N load intervals. Additionally, peri-implant parameters based on micro-CT volume data were recorded. Data were subjected to a two-sided nonparametric Wilcoxon signed rank test, and between-group comparisons were assessed with a Mann-Whitney test (alpha = .05). Initial load application led to displacement beyond elastic recovery of the surrounding bone after force release (P < .001). Cortical thickness and insertion depth, despite numeric differences, did not reveal any statistical differences, while displacement of mini-implants was significantly affected by contact to neighboring teeth (P < .001). Insertion technique and initial load application on orthodontic mini-implants may be regarded as two crucial factors for success, while repeated application of orthodontic force does not seem to increase screw mobility.
Gelb, David; McAllister, Bradley; Nummikoski, Pirkka; Del Fabbro, Massimo
2013-01-01
The aim of this study was to evaluate the clinical and radiographic long-term outcomes of dental implants with an anodized TiUnite surface, placed in routine clinical practice. Two clinical centers participated in the study. One hundred and seven implants (80 in the maxilla and 27 in the mandible) in 52 patients were followed in the long term. Both one- and two-stage techniques were used for 38 and 69 implants, respectively. Thirty-eight single tooth restorations and 22 fixed partial prostheses were delivered, according to a delayed loading protocol, within 4 to 12 months since implant placement. All implants were stable at insertion and at the long-term follow-up visit, which occurred between 7 and 8 years of functional loading. The mean followup was 7.33 ± 0.47 years. The mean marginal bone level change at the long-term followup as compared to baseline was 1.49 ± 1.03 mm. No implant failure occurred. Healthy peri-implant mucosa was found around 95% of implants, whereas 91% of implants showed no visible plaque at the implant surfaces at the long-term followup. The study showed that dental implants with the TiUnite anodized surface demonstrate excellent long-term clinical and radiographic outcomes. PMID:23533412
Arinc, Hakan
2018-06-01
To evaluate the effects of prosthetic material on the degree of stress to the cortical bone, trabecular bone, framework, and implants using finite element analysis (FEA). A mandibular implant-supported fixed prosthesis was designed. Different prosthetic materials [cobalt-chromium-supported ceramic, zirconia-supported ceramic, and zirconia-reinforced polymethyl methacrylate (ZRPMMA)-supported resin] were used. FEA was used to evaluate stress under different loading conditions. Maximum principal (σmax), minimum principal (σmin), and von Mises (σvM) stress values were obtained. Similar σmax, σmin, and σvM values were observed in the cortical and trabecular bones and in implants under both loading conditions, with the exception of the ZRPMMA model, which showed the highest σmax, σmin, and σvM values in oblique loading. The ZRPMMA model had the lowest σvM value in the framework under both loading conditions. ZRPMMA had the lowest stress values in the framework, with increased stress values in the implants and bone tissue. Framework and veneering materials may influence stress values under different loading conditions.
Effect of Magnetic Field on Bone Healing around Endosseous Implants – An In-vivo Study
Anam, Chandrasekar; Mamidi, Praveen; Chiluka, Radha; Kumar, A. Gautam; Bibinagar, Ragini
2016-01-01
Introduction After implant placement, a stress-free healing period of 3-6 months is a pre-requisite to achieve good osseointegration. If this duration could be reduced, the patients would feel happier. Eventhough, immediate loading of implants is a clinically feasible concept; it is not possible in certain situations. Few studies have shown that Static magnetic field is useful to promote bone formation faster after the bone is wounded. Aim This pilot study was intended to evaluate the tissue response after implant placement under the influence of magnetic field. Materials and Methods Twenty Tidal Spiral implants were used for this study. Two implants were placed in each patient in the anterior mandible corresponding to the B and D regions and the implant on the D region was exposed to magnetic field using safer magnet (Neodymium Boron Iron) and the implant on the B region served as a control. Both the implants were compared for stability using Resonance Frequency Analyzer (RFA) at Days 0, 30, 60 and 90. Mean Implant Stability Quotient (ISQ) values were compared on both sides using student’s paired t-test and repeated measures ANOVA (analysis of variance). There was a significant difference in the mean ISQ values, hence, a post-hoc test was done to evaluate whether there is any difference between the follow-ups. Results The average ISQ value for implants at 0 day in the B and D regions was 68.6 and 68.7 respectively. The average ISQ value at 30th day, 60th day and 90th day was 73.25, 76.05 and 78.95 respectively on the magnetic side (D region). Whereas on the non-magnetic side (B region) at 30th day, 60th day and 90th day was 68.45, 72.05 and 74.45 respectively. Conclusion The implant stability quotient values obtained on the magnetic side were significantly greater than on the non-magnetic side. Positive correlation exists between the magnetic field and osseointegration. PMID:27891492
Thoma, Daniel S; Benic, Goran I; Muñoz, Fernando; Kohal, Ralf; Sanz Martin, Ignacio; Cantalapiedra, Antonio G; Hämmerle, Christoph H F; Jung, Ronald E
2016-04-01
The aim was to test whether or not the marginal bone-level alterations of loaded zirconia implants are similar to the bone-level alterations of a grade 4 titanium one-piece dental implant. In six dogs, all premolars and the first molars were extracted in the mandible. Four months later, three zirconia implants (BPI, VC, ZD) and a control titanium one-piece (STM) implant were randomly placed in each hemimandible and left for transmucosal healing (baseline). Six months later, CAD/CAM crowns were cemented. Sacrifice was scheduled at 6-month postloading. Digital X-rays were taken at implant placement, crowns insertion, and sacrifice. Marginal bone-level alterations were calculated, and intra- and intergroup comparisons performed adjusted by confounding factors. Implants were successfully placed. Until crown insertion, two implants were fractured (one VC, one ZD). At sacrifice, 5 more implants were (partly) fractured (one BPI, four ZD), and one lost osseointegration (VC). No decementation of crowns occurred. All implant systems demonstrated a statistically significant (except VC) loss of marginal bone between baseline and crown insertion ranging from 0.29 mm (VC; P = 0.116) to 0.80 mm (ZD; P = 0.013). The estimated marginal bone loss between baseline and 6 months of loading ranged between 0.19 mm (BPI) and 1.11 mm (VC), being statistically significant for STM and VC only (P < 0.05). The changes in marginal bone levels were statistically significantly different between zirconia implants and control implants (STM vs. BPI P = 0.007; vs. VC P = 0.001; vs. ZD P = 0.011). Zirconia implants were more prone to fracture prior to and after loading with implant-supported crowns compared to titanium implants. Individual differences and variability in the extent of the bone-level changes during the 12-month study period were found between the different implant types and materials. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
ELsyad, Moustafa Abdou; Errabti, Hatem Mokhtar; Mustafa, Aisha Zakaria
2016-12-01
The aim of this in vitro study was to evaluate and compare mandibular denture base deformation between ball and Locator attachments of implant-retained overdentures. An experimental acrylic model covered with resilient silicone mucosal simulation was constructed. Two laboratory implants were placed in the canine areas of the model. Two duplicate experimental overdentures were constructed and connected to the implants with either ball (GI) or Locator (GII) attachments. To measure overdenture strain around the attachments, 3 strain gauges were attached to the lingual polished surface of the overdentures opposite to the right implant (loading side) 2 mm above the attachment level (Ch1), at the attachment level (Ch2), and 2 mm below the attachment level (Ch3). Another 3 gauges were bonded opposite to the left implant (non-loading side) in the same manner (Ch6, Ch7, and Ch8). To measure strain at the midline of the overdentures, two strain gauges were attached in the midline at 5 mm intervals (Ch4 and Ch5). A universal testing device was used to deliver vertical static load of 50 N unilaterally and bilaterally to the first molar area to measure strain using a multi-channel digital strain meter. During bilateral load application, GII recorded higher compressive strains than GI at the majority of channels. During unilateral load application, GI recorded higher tensile strains at Ch1, Ch2, and Ch3, and GII recorded higher strains than GI at Ch6, Ch7, and Ch8. During bilateral loading the highest strain was concentrated at Ch5 for both groups. During unilateral loading, the highest strain was concentrated at Ch2 for GI, and at Ch5 for GII. Ball attachments for implant-retained overdentures were associated with significant mandibular denture base deformation over the implants compared to Locator attachments. Therefore, denture base reinforcement may be recommended with ball attachmentz to increase fracture resistance of the base. © 2015 by the American College of Prosthodontists.
Aihara, Leandro Jun; Nanni, Rafael Augusto; Carvalho, Marina Sousa; Zamboni, Caio; Durigan, Jorge R; Hungria Neto, José S; Mercadante, Marcelo T; Christian, Ralph W; Hungria, José O S
2017-10-01
This study measured the tip-apex distance (TAD) values in the immediate postoperative period and following weight-bearing and fracture impaction in patients undergoing osteosynthesis with dynamic hip screw and cephalomedullary nail. To correlate the Baumgaertner index in the immediate postoperative period with values obtained after impaction of the fracture with the accommodation of the cephalic implant in the femoral head. Radiographic TAD measurements were taken with AGFA-VIEW ® of 82 patients with a mean age of 72 years with pertrochanteric fractures who were operated on and the fracture fixed with DHS- Synthes ® , TFN-Synthes ® , or Gamma Nail III-Stryker ® in the immediate postoperative period, and following weight-bearing and fracture impaction (mean 3-8 weeks after surgery). The overall average TAD decreased from 20.3mm to 18.2mm. Regardless of the instability of the fracture, the age of the patient or the implant used, TAD decreased between the immediate postoperative period and following fracture impaction. The osteosynthesis of pertrochanteric fractures was associated with important accommodation of the cephalic implant in the femoral head with decreased TAD values after weight-bearing. © 2017 Elsevier Ltd. All rights reserved.
Jagsi, Reshma; Jiang, Jing; Momoh, Adeyiza O.; Alderman, Amy; Giordano, Sharon H.; Buchholz, Thomas A.; Pierce, Lori J.; Kronowitz, Steven J.; Smith, Benjamin D.
2016-01-01
Objective To evaluate complications after post-mastectomy breast reconstruction, particularly in the setting of adjuvant radiotherapy. Summary-Background Data Most studies of complications after breast reconstruction have been conducted at centers of excellence; relatively little is known about complication rates in radiated patients treated in the broader community. This information is relevant for breast cancer patients' decision-making. Methods Using the claims-based MarketScan database, we described complications in 14,894 women undergoing mastectomy for breast cancer from 1998-2007 who received immediate autologous reconstruction (n=2637), immediate implant-based reconstruction (n=3007), or no reconstruction within the first two postoperative years (n=9250). We used a generalized estimating equation to evaluate associations between complications and radiotherapy over time. Results Wound complications were diagnosed within the first two postoperative years in 2.3% of patients without reconstruction, 4.4% with implants, and 9.5% with autologous reconstruction (p<0.001). Infection was diagnosed within the first two postoperative years in 12.7% of patients without reconstruction, 20.5% with implants, and 20.7% with autologous reconstruction (p<0.001). 5219 (35%) women received radiation. Radiation was not associated with infection in any surgical group within the first six months but was associated with an increased risk of infection in months 7-24 in all three groups (each p<0.001). In months 7-24, radiation was associated with higher odds of implant removal in patients with implant reconstruction (OR 1.48, p<0.001) and fat necrosis in those with autologous reconstruction (OR=1.55; P=0.01). Conclusions Complication risks after immediate breast reconstruction differ by approach. Radiation therapy appears to modestly increase certain risks, including infection and implant removal. PMID:25876011
[Mechanical studies of lumbar interbody fusion implants].
Bader, R J; Steinhauser, E; Rechl, H; Mittelmeier, W; Bertagnoli, R; Gradinger, R
2002-05-01
In addition to autogenous or allogeneic bone grafts, fusion cages composed of metal or plastic are being used increasingly as spacers for interbody fusion of spinal segments. The goal of this study was the mechanical testing of carbon fiber reinforced plastic (CFRP) fusion cages used for anterior lumbar interbody fusion. With a special testing device according to American Society for Testing and Materials (ASTM) standards, the mechanical properties of the implants were determined under four different loading conditions. The implants (UNION cages, Medtronic Sofamor Danek) provide sufficient axial compression, shear, and torsional strength of the implant body. Ultimate axial compression load of the fins is less than the physiological compression loads at the lumbar spine. Therefore by means of an appropriate surgical technique parallel grooves have to be reamed into the endplates of the vertebral bodies according to the fin geometry. Thereby axial compression forces affect the implants body and the fins are protected from damaging loading. Using a supplementary anterior or posterior instrumentation, in vivo failure of the fins as a result of physiological shear and torsional spinal loads is unlikely. Due to specific complications related to autogenous or allogeneic bone grafts, fusion cages made of metal or carbon fiber reinforced plastic are an important alternative implant in interbody fusion.
Favero, Giacomo; Botticelli, Daniele; Favero, Giovanni; García, Brismayda; Mainetti, Tomaso; Lang, Niklaus P
2013-01-01
To evaluate the influence of deproteinized bovine bone mineral in conjunction with a collagen membrane, at implants installed into sockets in a lingual position immediately after tooth extraction, and presenting initial horizontal residual buccal defects <2 mm. The pulp tissue of the mesial roots of (4)P(4) was removed in six Labrador dogs, and the root canals were filled with gutta-percha and cement. Flaps were elevated, and the buccal and lingual alveolar bony plates were exposed. The premolars were hemi-sectioned, and the distal roots were removed. Implants were installed in a lingual position and with the margin flush with the buccal bony crest. After installation, defects resulted at about 1.7 mm in width at the buccal aspects, both at the test and control sites. Only in the left site (test), deproteinized bovine bone mineral (DBBM) particles were placed into the defect concomitantly with the placement of a collagen membrane. A non-submerged healing was allowed. After 3 months of healing, one implant was found not integrated and was excluded from the analysis together with the contralateral control implant. All remaining implants were integrated into mature bone. The bony crest was located at the same level of the implant shoulder, both at the test and control sites. At the buccal aspect, the most coronal bone-to-implant contact was located at a similar distance from the implant margin at the test (1.7 ± 1.0 mm) and control (1.6 ± 0.8 mm) sites, respectively. Only small residual DBBM particles were found at the test sites. The placement of an implant in a lingual position into a socket immediately after tooth extraction may favor a low exposure of the buccal implant surface. The use of DBBM particles, concomitantly with a collagen membrane, did not additionally improve the outcome obtained at the control sites. © 2011 John Wiley & Sons A/S.
Vallejo-Heligon, Suzana G; Brown, Nga L; Reichert, William M; Klitzman, Bruce
2016-01-01
Continuous glucose sensors offer the promise of tight glycemic control for insulin dependent diabetics; however, utilization of such systems has been hindered by issues of tissue compatibility. Here we report on the in vivo performance of implanted glucose sensors coated with Dexamethasone-loaded (Dex-loaded) porous coatings employed to mediate the tissue-sensor interface. Two animal studies were conducted to (1) characterize the tissue modifying effects of the porous Dex-loaded coatings deployed on sensor surrogate implants and (2) investigate the effects of the same coatings on the in vivo performance of Medtronic MiniMed SOF-SENSOR™ glucose sensors. The tissue response to implants was evaluated by quantifying macrophage infiltration, blood vessel formation, and collagen density around implants. Sensor function was assessed by measuring changes in sensor sensitivity and time lag, calculating the Mean Absolute Relative Difference (MARD) for each sensor treatment, and performing functional glucose challenge test at relevant time points. Implants treated with porous Dex-loaded coatings diminished inflammation and enhanced vascularization of the tissue surrounding the implants. Functional sensors with Dex-loaded porous coatings showed enhanced sensor sensitivity over a 21-day period when compared to controls. Enhanced sensor sensitivity was accompanied with an increase in sensor signal lag and MARD score. These results indicate that Dex-loaded porous coatings were able to elicit an attenuated tissue response, and that such tissue microenvironment could be conducive towards extending the performance window of glucose sensors in vivo. In the present article, a coating to extend the functionality of implantable glucose sensors in vivo was developed. Our study showed that the delivery of an anti-inflammatory agent with the presentation of micro-sized topographical cues from coatings may lead to improved long-term glucose sensor function in vivo. We believe that improved function of sensors treated with the novel coatings was a result of the observed decreases in inflammatory cell density and increases in vessel density of the tissue adjacent to the devices. Furthermore, extending the in vivo functionality of implantable glucose sensors may lead to greater adoption of these devices by diabetic patients. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
2016-01-01
This prospective 3-year follow-up clinical study evaluated the survival and success rates of 3DP/AM titanium dental implants to support single implant-supported restorations. After 3 years of loading, clinical, radiographic, and prosthetic parameters were assessed; the implant survival and the implant-crown success were evaluated. Eighty-two patients (44 males, 38 females; age range 26–67 years) were enrolled in the present study. A total of 110 3DP/AM titanium dental implants (65 maxilla, 45 mandible) were installed: 75 in healed alveolar ridges and 35 in postextraction sockets. The prosthetic restorations included 110 single crowns (SCs). After 3 years of loading, six implants failed, for an overall implant survival rate of 94.5%; among the 104 surviving implant-supported restorations, 6 showed complications and were therefore considered unsuccessful, for an implant-crown success of 94.3%. The mean distance between the implant shoulder and the first visible bone-implant contact was 0.75 mm (±0.32) and 0.89 (±0.45) after 1 and 3 years of loading, respectively. 3DP/AM titanium dental implants seem to represent a successful clinical option for the rehabilitation of single-tooth gaps in both jaws, at least until 3-year period. Further, long-term clinical studies are needed to confirm the present results. PMID:27313616
Tunchel, Samy; Blay, Alberto; Kolerman, Roni; Mijiritsky, Eitan; Shibli, Jamil Awad
2016-01-01
This prospective 3-year follow-up clinical study evaluated the survival and success rates of 3DP/AM titanium dental implants to support single implant-supported restorations. After 3 years of loading, clinical, radiographic, and prosthetic parameters were assessed; the implant survival and the implant-crown success were evaluated. Eighty-two patients (44 males, 38 females; age range 26-67 years) were enrolled in the present study. A total of 110 3DP/AM titanium dental implants (65 maxilla, 45 mandible) were installed: 75 in healed alveolar ridges and 35 in postextraction sockets. The prosthetic restorations included 110 single crowns (SCs). After 3 years of loading, six implants failed, for an overall implant survival rate of 94.5%; among the 104 surviving implant-supported restorations, 6 showed complications and were therefore considered unsuccessful, for an implant-crown success of 94.3%. The mean distance between the implant shoulder and the first visible bone-implant contact was 0.75 mm (±0.32) and 0.89 (±0.45) after 1 and 3 years of loading, respectively. 3DP/AM titanium dental implants seem to represent a successful clinical option for the rehabilitation of single-tooth gaps in both jaws, at least until 3-year period. Further, long-term clinical studies are needed to confirm the present results.
Retention of cast crown copings cemented to implant abutments.
Dudley, J E; Richards, L C; Abbott, J R
2008-12-01
The cementation of crowns to dental implant abutments is an accepted form of crown retention that requires consideration of the properties of available cements within the applied clinical context. Dental luting agents are exposed to a number of stressors that may reduce crown retention in vivo, not the least of which is occlusal loading. This study investigated the influence of compressive cyclic loading on the physical retention of cast crown copings cemented to implant abutments. Cast crown copings were cemented to Straumann synOcta titanium implant abutments with three different readily used and available cements. Specimens were placed in a humidifier, thermocycled and subjected to one of four quantities of compressive cyclic loading. The uniaxial tensile force required to remove the cast crown copings was then recorded. The mean retention values for crown copings cemented with Panavia-F cement were statistically significantly greater than both KetacCem and TempBond non-eugenol cements at each compressive cyclic loading quantity. KetacCem and TempBond non-eugenol cements produced relatively low mean retention values that were not statistically significantly different at each quantity of compressive cyclic loading. Compressive cyclic loading had a statistically significant effect on Panavia-F specimens alone, but increased loading quantities produced no further statistically significant difference in mean retention. Within the limitations of the current in vitro conditions employed in this study, the retention of cast crown copings cemented to Straumann synOcta implant abutments with a resin, glass ionomer and temporary cement was significantly affected by cement type but not compressive cyclic loading. Resin cement is the cement of choice for the definitive non-retrievable cementation of cast crown copings to Straumann synOcta implant abutments out of the three cements tested.
Mohammed, Hnd Hadi; Lee, Jin-Han; Bae, Ji-Myung; Cho, Hye-Won
2016-02-01
The purpose of this study was to evaluate the effects of abutment screw length and cyclic loading on the removal torque (RTV) in external hex (EH) and internal hex (IH) implants. Forty screw-retained single crowns were connected to external and internal hex implants. The prepared titanium abutment screws were classified into 8 groups based on the number of threads (n = 5 per group): EH 12.5, 6.5, 3.5, 2.5 and IH 6.5, 5, 3.5, 2.5 threads. The abutment screws were tightened with 20 Ncm torque twice with 10-minute intervals. After 5 minutes, the initial RTVs of the abutment screws were measured with a digital torque gauge (MGT12). A customized jig was constructed to apply a load along the implant long axis at the central fossa of the maxillary first molar. The post-loading RTVs were measured after 16,000 cycles of mechanical loading with 50 N at a 1-Hz frequency. Statistical analysis included one-way analysis of variance and paired t-tests. The post-loading RTVs were significantly lower than the initial RTVs in the EH 2.5 thread and IH 2.5 thread groups (P<.05). The initial RTVs exhibited no significant differences among the 8 groups, whereas the post-loading RTVs of the EH 6.5 and EH 3.5 thread groups were higher than those of the IH 3.5 thread group (P<.05). Within the limitations of this study, the external hex implants with short screw lengths were more advantageous than internal hex implants with short screw lengths in torque maintenance after cyclic loading.
Mohammed, Hnd Hadi; Lee, Jin-Han; Bae, Ji-Myung
2016-01-01
PURPOSE The purpose of this study was to evaluate the effects of abutment screw length and cyclic loading on the removal torque (RTV) in external hex (EH) and internal hex (IH) implants. MATERIALS AND METHODS Forty screw-retained single crowns were connected to external and internal hex implants. The prepared titanium abutment screws were classified into 8 groups based on the number of threads (n = 5 per group): EH 12.5, 6.5, 3.5, 2.5 and IH 6.5, 5, 3.5, 2.5 threads. The abutment screws were tightened with 20 Ncm torque twice with 10-minute intervals. After 5 minutes, the initial RTVs of the abutment screws were measured with a digital torque gauge (MGT12). A customized jig was constructed to apply a load along the implant long axis at the central fossa of the maxillary first molar. The post-loading RTVs were measured after 16,000 cycles of mechanical loading with 50 N at a 1-Hz frequency. Statistical analysis included one-way analysis of variance and paired t-tests. RESULTS The post-loading RTVs were significantly lower than the initial RTVs in the EH 2.5 thread and IH 2.5 thread groups (P<.05). The initial RTVs exhibited no significant differences among the 8 groups, whereas the post-loading RTVs of the EH 6.5 and EH 3.5 thread groups were higher than those of the IH 3.5 thread group (P<.05). CONCLUSION Within the limitations of this study, the external hex implants with short screw lengths were more advantageous than internal hex implants with short screw lengths in torque maintenance after cyclic loading. PMID:26949489
Cehreli, Murat Cavit; Uysal, Serdar; Akca, Kivanc
2010-06-01
Documentation of early loading of mandibular overdentures supported by different implant systems is scarce. This study aimed to compare the biologic and prosthetic outcome of mandibular overdentures supported by unsplinted early-loaded one- and two-stage oral implants after 5 years of function. Twenty-eight consecutive patients were screened following an inclusion and exclusion criteria, and randomly allocated to treatment groups. Ball-retained mandibular overdentures were fabricated on two unsplinted Straumann (Institut Straumann AG, Basel, Switzerland) and Brånemark (Nobel Biocare AB, Göteborg, Sweden) dental implants and subjected to an early-loading protocol. During the 5-year period, prosthetic complications were recorded. At 5-years of function, plaque, peri-implant inflammation, bleeding, and calculus index scores were recorded, and standard periapical radiographs were obtained from each implant for measurement of marginal bone loss. All implants survived during the observation period. The peri-implant inflammation, bleeding, and calculus index scores around Straumann and Brånemark implants were similar (p > .05). The marginal bone loss around Brånemark implants (1.21 +/- 0.1) was higher than Straumann implants (0.73 +/- 0.06) at 5 years of function (p = .002). Kaplan-Meier tests revealed that 1- and 5-year survival of overdentures on Straumann and Brånemark implants were similar (p = .85). Wear of the ball abutment in the Brånemark group was higher than in the Straumann group (p < .05). Complications regarding the retainer and the need for occlusal adjustments were higher in the Straumann group (p < .05). Chi-square test revealed that the frequency of retightening of the retainer was higher in the Straumann group than in the Brånemark group (p < .05). Mandibular overdentures supported by unsplinted early-loaded Straumann and Brånemark implants lead to similar peri-implant soft tissue and prosthetic outcomes, although higher marginal bone loss could be observed around Brånemark implants after 5 years.
Huang, Hairong; Xu, Zanzan; Shao, Xianhong; Wismeijer, Daniel; Sun, Ping; Wang, Jingxiao
2017-01-01
Objectives This study identified potential general influencing factors for a mathematical prediction of implant stability quotient (ISQ) values in clinical practice. Methods We collected the ISQ values of 557 implants from 2 different brands (SICace and Osstem) placed by 2 surgeons in 336 patients. Surgeon 1 placed 329 SICace implants, and surgeon 2 placed 113 SICace implants and 115 Osstem implants. ISQ measurements were taken at T1 (immediately after implant placement) and T2 (before dental restoration). A multivariate linear regression model was used to analyze the influence of the following 11 candidate factors for stability prediction: sex, age, maxillary/mandibular location, bone type, immediate/delayed implantation, bone grafting, insertion torque, I-stage or II-stage healing pattern, implant diameter, implant length and T1-T2 time interval. Results The need for bone grafting as a predictor significantly influenced ISQ values in all three groups at T1 (weight coefficients ranging from -4 to -5). In contrast, implant diameter consistently influenced the ISQ values in all three groups at T2 (weight coefficients ranging from 3.4 to 4.2). Other factors, such as sex, age, I/II-stage implantation and bone type, did not significantly influence ISQ values at T2, and implant length did not significantly influence ISQ values at T1 or T2. Conclusions These findings provide a rational basis for mathematical models to quantitatively predict the ISQ values of implants in clinical practice. PMID:29084260
Rose, Sally B; Garrett, Susan M; Stanley, James
2015-07-01
The aims of this study were to compare immediate postabortion uptake of recently subsidized (no-cost) levonorgestrel-releasing implants with already available intrauterine and shorter-acting methods and to compare the incidence of subsequent pregnancies (ending in birth or abortion) within 2 years. Retrospective chart review of 4698 women attending a New Zealand public hospital abortion clinic over 2 years (2010-2012) to describe postabortion contraceptive choice, with follow-up via clinic and national births records to assess subsequent pregnancies at 12, 24, 36, and 48 months. Twenty percent of the cohort (934/4698) received an implant, 26% an intrauterine method (927 copper intrauterine device, 301 levonorgestrel-releasing intrauterine system [LNG-IUS]), and 54% chose other shorter-acting methods (2536/4698). Method choice was significantly associated with age, ethnicity, and pregnancy history (p < .001). At 24 months, the unadjusted incidence of subsequent abortion for implant users was 3.8% (95% confidence interval [CI] = 2.5-5.0) and 11.6% (95% CI = 10.3-12.8) for those choosing other short-acting methods. By 48 months, 6.6% of implant users had a subsequent abortion (compared with 18.3% for short-acting methods). The incidence of continued pregnancy at 24 months was 6.3% (95% CI = 4.4-8.1) for implant users and 15.7% (95% CI = 14-17.2) for those choosing other short-acting methods. Adjusted hazard ratios (HRs) for subsequent abortion were lowest for women initiating an implant (HR = 0.26, 95% CI = 0.20-0.35) or LNG-IUS (HR = 0.26, 0.16-0.44, reference group: short-acting methods). Immediate postabortion insertion of an implant significantly reduced rates of subsequent pregnancy for at least 2 years. Abortion service providers should ensure women have barrier-free access to all long-acting reversible contraceptions to delay or prevent pregnancy. Initiation of an levonorgestrel implant immediately postabortion was associated with a 74% reduction in subsequent abortion over the next 4 years compared with use of short-acting methods. Implants were popular among adolescents-a group at high-risk of subsequent pregnancy, and who have not historically been considered appropriate candidates for intrauterine contraceptive methods. Copyright © 2015 Elsevier Inc. All rights reserved.
Brizuela-Velasco, Aritza; Álvarez-Arenal, Ángel; Gil-Mur, Francisco Javier; Herrero-Climent, Mariano; Chávarri-Prado, David; Chento-Valiente, Yelko; Dieguez-Pereira, Markel
2015-10-01
To evaluate the micromobility of dental implants under occlusal loading in relation to stability measurements of resonance frequency analysis and insertion torque. The sample comprised of 24 implants inserted in 12 fresh cow ribs. Insertion torque and Osstell implant stability quotient (ISQ) measurements were recorded. An "ad hoc" acrylic premolar was made on a temporary abutment and screwed to each implant, and a force of 100 N was subsequently applied at an angle of 6 degrees. Implant micromotion was measured using a Questar microscope with a resolution of 2 μm and an image analysis program. Data show a statistically significant inverse correlation between the ISQ values and implant micromotion under a load of 100 N (R = 0.86, P < 0.0001). The same relationship is found between insertion torque and implant micromotion, although the relationship is linear up to 34 N·cm and becomes exponential for higher values (R = 0.78, P < 0.0001). A direct correlation is established between insertion torque and ISQ values. There is an inverse relationship between both ISQ and insertion torque values and implant micromotion under a load of 100 N.
Load Transfer Characteristics of Various Designs of Three-Implant-Retained Mandibular Overdentures.
Tokar, Emre; Uludag, Bulent
2015-01-01
Many different attachment systems (eg, bars, studs, magnets, telescopic copings) have been used to retain overdentures. The current study aimed to investigate the load transfer characteristics and to compare the stress levels of four attachment designs for mandibular overdentures retained by one central implant and two inclined distal implants. Photoelastic mandibular models fabricated with three screw-type implants (Tapered Screw-Vent, 3.75 × 13 mm) were placed in the parasymphyseal area. The center implant was vertically oriented to the midline, and the other implants were embedded in the canine areas with a 20-degree angulation relative to the center implant. Four overdentures with different attachment designs (bar, bar/ball, bar/distally placed Rk-1s, and Locators) were studied in the context of this model. Vertical loads (100 N) were applied to the central fossa of the right first molar area of each overdenture. Stress levels that developed in the denture-bearing areas and around the implants were observed photoelastically and evaluated visually. The studied attachment designs showed low and moderate stress levels. The greatest stress was found with the bar/ball design, while the lowest stress levels were observed with the Locator attachment design. Stresses were concentrated on the loaded side for each design. All tested designs experienced moderate stress around the posterior edentulous area. None of the designs experienced more than moderate stress. The lowest stress was noted with the Locator attachments, which transmitted little discernible stress around the implants.
SUEDAM, Valdey; MORETTI, Rafael Tobias; SOUSA, Edson Antonio Capello; RUBO, José Henrique
2016-01-01
ABSTRACT Because many mechanical variables are present in the oral cavity, the proper load transfer between the prosthesis and the bone is important for treatment planning and for the longevity of the implant-supported fixed partial denture. Objectives To verify the stress generated on the peri-implant area of cantilevered implant-supported fixed partial dentures and the potential effects of such variable. Material and Methods A U-shaped polyurethane model simulating the mandibular bone containing two implants (Ø 3.75 mm) was used. Six groups were formed according to the alloy’s framework (CoCr or PdAg) and the point of load application (5 mm, 10 mm and 15 mm of cantilever arm). A 300 N load was applied in pre-determined reference points. The tension generated on the mesial, lingual, distal and buccal sides of the peri-implant regions was assessed using strain gauges. Results Two-way ANOVA and Tukey statistical tests were applied showing significant differences (p<0.05) between the groups. Pearson correlation test (p<0.05) was applied showing positive correlations between the increase of the cantilever arm and the deformation of the peri-implant area. Conclusions This report demonstrated the CoCr alloy shows larger compression values compared to the PdAg alloy for the same distances of cantilever. The point of load application influences the deformation on the peri-implant area, increasing in accordance with the increase of the lever arm. PMID:27119758
Troedhan, Angelo; Schlichting, Izabela; Kurrek, Andreas; Wainwright, Marcel
2014-01-01
Implant-Insertion-Torque-Value (ITV) proved to be a significant clinical parameter to predict long term implant success-rates and to decide upon immediate loading. The study evaluated ITVs, when four different and commonly used biomaterials were used in sinuslift-procedures compared to natural subantral bone in two-stage-implant-procedures. The tHUCSL-INTRALIFT-method was chosen for sinuslifting in 155 sinuslift-sites for its minimal invasive transcrestal approach and scalable augmentation volume. Four different biomaterials were inserted randomly (easy-graft CRYSTAL n = 38, easy-graft CLASSIC n = 41, NanoBone n = 42, BioOss n = 34), 2 ccm in each case. After a mean healing period of 8,92 months uniform tapered screw Q2-implants were inserted and Drill-Torque-Values (DTV) and ITV were recorded and compared to a group of 36 subantral sites without need of sinuslifting. DTV/ITV were processed for statistics by ANOVA-tests. Mean DTV/ITV obtained in Ncm were: Control Group 10,2/22,2, Bio-Oss 12,7/26,2, NanoBone 17,5/33,3, easy-graft CLASSIC 20,3/45,9, easy-graft CRYSTAL 23,8/56,6 Ncm, significance-level of differences throughout p < 0,05. Within the limits of this study the results suggest self-hardening solid-block-like bone-graft-materials to achieve significantly better DTV/ITV than loose granulate biomaterials for its suspected improvement of vascularization and mineralization of the subantral scaffold by full immobilization of the augmentation site towards pressure changes in the human sinus at normal breathing. PMID:25073446
Kang, He-Kyong; Chu, Tien-Min; Dechow, Paul; Stewart, Kelton; Kyung, Hee-Moon
2016-01-01
Summary Background/Objectives: This study investigated the biomechanical properties and bone-implant intersurface response of machined and laser surface-treated stainless steel (SS) mini-screw implants (MSIs). Material and Methods: Forty-eight 1.3mm in diameter and 6mm long SS MSIs were divided into two groups. The control (machined surface) group received no surface treatment; the laser-treated group received Nd-YAG laser surface treatment. Half in each group was used for examining surface roughness (Sa and Sq), surface texture, and facture resistance. The remaining MSIs were placed in the maxilla of six skeletally mature male beagle dogs in a randomized split-mouth design. A pair with the same surface treatment was placed on the same side and immediately loaded with 200g nickel–titanium coil springs for 8 weeks. After killing, the bone-implant contact (BIC) for each MSI was calculated using micro computed tomography. Analysis of variance model and two-sample t test were used for statistical analysis with a significance level of P <0.05. Results: The mean values of Sa and Sq were significantly higher in the laser-treated group compared with the machined group (P <0.05). There were no significant differences in fracture resistance and BIC between the two groups. Limitation: animal study Conclusions/Implications: Laser treatment increased surface roughness without compromising fracture resistance. Despite increasing surface roughness, laser treatment did not improve BIC. Overall, it appears that medical grade SS has the potential to be substituted for titanium alloy MSIs. PMID:25908868
Troedhan, Angelo; Schlichting, Izabela; Kurrek, Andreas; Wainwright, Marcel
2014-07-30
Implant-Insertion-Torque-Value (ITV) proved to be a significant clinical parameter to predict long term implant success-rates and to decide upon immediate loading. The study evaluated ITVs, when four different and commonly used biomaterials were used in sinuslift-procedures compared to natural subantral bone in two-stage-implant-procedures. The tHUCSL-INTRALIFT-method was chosen for sinuslifting in 155 sinuslift-sites for its minimal invasive transcrestal approach and scalable augmentation volume. Four different biomaterials were inserted randomly (easy-graft CRYSTAL n = 38, easy-graft CLASSIC n = 41, NanoBone n = 42, BioOss n = 34), 2 ccm in each case. After a mean healing period of 8,92 months uniform tapered screw Q2-implants were inserted and Drill-Torque-Values (DTV) and ITV were recorded and compared to a group of 36 subantral sites without need of sinuslifting. DTV/ITV were processed for statistics by ANOVA-tests. Mean DTV/ITV obtained in Ncm were: Control Group 10,2/22,2, Bio-Oss 12,7/26,2, NanoBone 17,5/33,3, easy-graft CLASSIC 20,3/45,9, easy-graft CRYSTAL 23,8/56,6 Ncm, significance-level of differences throughout p < 0,05. Within the limits of this study the results suggest self-hardening solid-block-like bone-graft-materials to achieve significantly better DTV/ITV than loose granulate biomaterials for its suspected improvement of vascularization and mineralization of the subantral scaffold by full immobilization of the augmentation site towards pressure changes in the human sinus at normal breathing.
Spinal loads as influenced by external loads: a combined in vivo and in silico investigation.
Zander, Thomas; Dreischarf, Marcel; Schmidt, Hendrik; Bergmann, Georg; Rohlmann, Antonius
2015-02-26
Knowledge of in vivo spinal loads and muscle forces remains limited but is necessary for spinal biomechanical research. To assess the in vivo spinal loads, measurements with telemeterised vertebral body replacements were performed in four patients. The following postures were investigated: (a) standing with arms hanging down on sides, (b) holding dumbbells to subject the patient to a vertical load, and (c) the forward elevation of arms for creating an additional flexion moment. The same postures were simulated by an inverse static model for validation purposes, to predict muscle forces, and to assess the spinal loads in subjects without implants. Holding dumbbells on sides increased implant forces by the magnitude of the weight of the dumbbells. In contrast, elevating the arms yielded considerable implant forces with a high correlation between the external flexion moment and the implant force. Predictions agreed well with experimental findings, especially for forward elevation of arms. Flexion moments were mainly compensated by erector spinae muscles. The implant altered the kinematics and, thus, the spinal loads. Elevation of both arms in vivo increased spinal axial forces by approximately 100N; each additional kg of dumbbell weight held in the hands increased the spinal axial forces by 60N. Model predictions suggest that in the intact situation, the force increase is one-third greater for these loads. In vivo measurements are essential for the validation of analytical models, and the combination of both methods can reveal unquantifiable data such as the spinal loads in the intact non-instrumented situation. Copyright © 2015 Elsevier Ltd. All rights reserved.
Verri, Fellippo Ramos; Cruz, Ronaldo Silva; Lemos, Cleidiel Aparecido Araújo; de Souza Batista, Victor Eduardo; Almeida, Daniel Augusto Faria; Verri, Ana Caroline Gonçales; Pellizzer, Eduardo Piza
2017-02-01
The aim of study was to evaluate the stress distribution in implant-supported prostheses and peri-implant bone using internal hexagon (IH) implants in the premaxillary area, varying surgical techniques (conventional, bicortical and bicortical in association with nasal floor elevation), and loading directions (0°, 30° and 60°) by three-dimensional (3D) finite element analysis. Three models were designed with Invesalius, Rhinoceros 3D and Solidworks software. Each model contained a bone block of the premaxillary area including an implant (IH, Ø4 × 10 mm) supporting a metal-ceramic crown. 178 N was applied in different inclinations (0°, 30°, 60°). The results were analyzed by von Mises, maximum principal stress, microstrain and displacement maps including ANOVA statistical test for some situations. Von Mises maps of implant, screws and abutment showed increase of stress concentration as increased loading inclination. Bicortical techniques showed reduction in implant apical area and in the head of fixation screws. Bicortical techniques showed slight increase stress in cortical bone in the maximum principal stress and microstrain maps under 60° loading. No differences in bone tissue regarding surgical techniques were observed. As conclusion, non-axial loads increased stress concentration in all maps. Bicortical techniques showed lower stress for implant and screw; however, there was slightly higher stress on cortical bone only under loads of higher inclinations (60°).
Babunashvili, A M; Navtsishvili, Z G; Konstantinov, B A
2016-02-01
The authors present immediate and long term results of the first in Russia implantation in coronary artery of Palmaz-Shatz metal stent. Indications for stenting were urgent after complicated dissection as a result of balloon dilation of discrete bifurcational stenosis of anterior interventricular artery (IVA). Immediate angiographic and clinical result was good. At control angiography after 13 years their was no restenosis in stented IVA. However novel narrowing was found in left main coronary artery (LMCA) in which drug eluting stent was implanted. Coronary angiography carried out after 7.5 years after stenting of LMCA and in 20 years after stent implantation in IVA revealed good patency of both stented segments without signs of restenosis. This case report demonstrates possibility of long term preservation of angiographic and clinical effect of staged endovascular treatment of coronary atherosclerosis.
Al-Nawas, B; Groetz, K A; Goetz, H; Duschner, H; Wagner, W
2008-01-01
Test of favourable conditions for osseointegration with respect to optimum bone-implant contact (BIC) in a loaded animal model. The varied parameters were surface roughness and surface topography of commercially available dental implants. Thirty-two implants of six types of macro and microstructure were included in the study (total 196). The different types were: minimally rough control: Branemark machined Mk III; oxidized surface: TiUnite MkIII and MkIV; ZL Ticer; blasted and etched surface: Straumann SLA; rough control: titanium plasma sprayed (TPS). Sixteen beagle dogs were implanted with the whole set of the above implants. After a healing period of 8 weeks, implants were loaded for 3 months. For the evaluation of the BIC areas, adequately sectioned biopsies were visualized by subsurface scans with confocal laser scanning microscopy (CLSM). The primary statistical analysis testing BIC of the moderately rough implants (mean 56.1+/-13.0%) vs. the minimally rough and the rough controls (mean 53.9+/-11.2%) does not reveal a significant difference (P=0.57). Mean values of 50-70% BIC were found for all implant types. Moderately rough oxidized implants show a median BIC, which is 8% higher than their minimally rough turned counterpart. The intraindividual difference between the TPS and the blasted and etched counterparts revealed no significant difference. The turned and the oxidized implants show median values of the resonance frequency [implant stability quotients (ISQ)] over 60; the nonself-tapping blasted and etched and TPS implants show median values below 60. In conclusion, the benefit of rough surfaces relative to minimally rough ones in this loaded animal model was confirmed histologically. The comparison of different surface treatment modalities revealed no significant differences between the modern moderately rough surfaces. Resonance frequency analysis seems to be influenced in a major part by the transducer used, thus prohibiting the comparison of different implant systems.
Finite element analysis of a novel implant distribution to support maxillary overdentures.
Osman, Reham B; Elkhadem, Amr H; Ma, Sunyoung; Swain, Michael V
2013-01-01
To evaluate the biomechanics of a novel implant placement distribution and compare it with that of conventional maxillary overdenture support using three-dimensional finite element analysis (FEA). The application of zirconia implants in the context of this novel design was also evaluated. Detailed FEA models were created to analyze the loading responses of two different distributions of implants to support maxillary overdentures. The two implant distributions were as follows: the conventional design (D1) included four unsplinted implants in the premolar regions, whereas the novel design (D2) included one midpalatal implant, bilateral canine/premolar implants, and one anterior off-center crestal implant. Anatomical models were created with computed tomographic data and static loads were applied axially and obliquely. Von Mises stresses and equivalent strains generated in peri-implant bone and first principal stresses in the implants were calculated, including any denture displacement. Comparable stress and strain values were seen in the peri-implant bone for both designs. A significant decrease in the first principal stresses of D2 implants was observed with oblique loads. The maximum equivalent strain produced in the peri-implant region was mostly within the range for bone augmentation. D2 displayed lower maximum displacement values than D1. Maximum tensile stresses in the zirconia implants for either design were well below their fracture strength. A novel four-implant distribution involving midpalatal and crestal implants may be an alternative to the conventional design used for maxillary overdentures. This is particularly relevant when anatomical considerations prevent the placement of four anterior crestal implants. Zirconia implants may also be a valid option for a selected group of patients or for those requesting metal-free restorations. Prospective clinical studies are required to confirm these in vitro results.
Revival of pure titanium for dynamically loaded porous implants using additive manufacturing.
Wauthle, Ruben; Ahmadi, Seyed Mohammad; Amin Yavari, Saber; Mulier, Michiel; Zadpoor, Amir Abbas; Weinans, Harrie; Van Humbeeck, Jan; Kruth, Jean-Pierre; Schrooten, Jan
2015-09-01
Additive manufacturing techniques are getting more and more established as reliable methods for producing porous metal implants thanks to the almost full geometrical and mechanical control of the designed porous biomaterial. Today, Ti6Al4V ELI is still the most widely used material for porous implants, and none or little interest goes to pure titanium for use in orthopedic or load-bearing implants. Given the special mechanical behavior of cellular structures and the material properties inherent to the additive manufacturing of metals, the aim of this study is to investigate the properties of selective laser melted pure unalloyed titanium porous structures. Therefore, the static and dynamic compressive properties of pure titanium structures are determined and compared to previously reported results for identical structures made from Ti6Al4V ELI and tantalum. The results show that porous Ti6Al4V ELI still remains the strongest material for statically loaded applications, whereas pure titanium has a mechanical behavior similar to tantalum and is the material of choice for cyclically loaded porous implants. These findings are considered to be important for future implant developments since it announces a potential revival of the use of pure titanium for additively manufactured porous implants. Copyright © 2015 Elsevier B.V. All rights reserved.
Shahmiri, Reza; Aarts, John M.; Bennani, Vincent; Swain, Michael V.
2013-01-01
Purpose. This in vitro study investigates how unilateral and bilateral occlusal loads are transferred to an implant assisted removable partial denture (IARPD). Materials and Methods. A duplicate model of a Kennedy class I edentulous mandibular arch was made and then a conventional removable partial denture (RPD) fabricated. Two Straumann implants were placed in the second molar region, and the prosthesis was modified to accommodate implant retained ball attachments. Strain gages were incorporated into the fitting surface of both the framework and acrylic to measure microstrain (μStrain). The IARPD was loaded to 120Ns unilaterally and bilaterally in three different loading positions. Statistical analysis was carried out using SPSS version 18.0 (SPSS, Inc., Chicago, IL, USA) with an alpha level of 0.05 to compare the maximum μStrain values of the different loading conditions. Results. During unilateral and bilateral loading the maximum μStrain was predominantly observed in a buccal direction. As the load was moved anteriorly the μStrain increased in the mesial area. Unilateral loading resulted in a twisting of the structure and generated a strain mismatch between the metal and acrylic surfaces. Conclusions. Unilateral loading created lateral and vertical displacement of the IARPD. The curvature of the dental arch resulted in a twisting action which intensified as the unilateral load was moved anteriorly. PMID:23737788
Immediate direct-to-implant breast reconstruction using anatomical implants.
Kim, Sung-Eun; Jung, Dong-Woo; Chung, Kyu-Jin; Lee, Jun Ho; Kim, Tae Gon; Kim, Yong-Ha; Lee, Soo Jung; Kang, Su Hwan; Choi, Jung Eun
2014-09-01
In 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience. From November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction. The mean breast resection volume was 240 mL (range, 83-540 mL). The mean size of the breast implants was 217 mL (range, 125-395 mL). Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen. By using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.
Coppedê, Abílio Ricciardi; Bersani, Edmilson; de Mattos, Maria da Gloria Chiarello; Rodrigues, Renata Cristina Silveira; Sartori, Ivete Aparecida de Mattias; Ribeiro, Ricardo Faria
2009-01-01
The objective of this study was to verify if differences in the design of internal hex (IH) and internal conical (IC) connection implant systems influence fracture resistance under oblique compressive forces. Twenty implant-abutment assemblies were utilized: 10 with IH connections and 10 with IC connections. Maximum deformation force for IC implants (90.58 +/- 6.72 kgf) was statistically higher than that for IH implants (83.73 +/- 4.94 kgf) (P = .0182). Fracture force for the IH implants was 79.86 +/- 4.77 kgf. None of the IC implants fractured. The friction-locking mechanics and the solid design of the IC abutments provided greater resistance to deformation and fracture under oblique compressive loading when compared to the IH abutments.
Dental implants typically help retain peri-implant vertical bone height: evidence-based analysis.
Greenstein, Gary; Cavallaro, John
2013-01-01
The dental literature is assessed regarding the ability of dental implants to maintain vertical bone height after various implant placement scenarios: immediate, delayed, insertion into partially and fully edentate healed ridges, and under overdentures. Studies are also reviewed to determine if bone loss after implant insertion is continuous. Numerous investigations that support the concept that implants preserve bone height are identified. In addition, the data indicate that a minuscule amount of annual bone loss usually persists after implant placement, but it is often clinically imperceptible.
Prosthetic breast reconstruction: indications and update
Quinn, Tam T.; Miller, George S.; Rostek, Marie; Cabalag, Miguel S.; Rozen, Warren M.
2016-01-01
Background Despite 82% of patients reporting psychosocial improvement following breast reconstruction, only 33% patients choose to undergo surgery. Implant reconstruction outnumbers autologous reconstruction in many centres. Methods A systematic review of the literature was undertaken. Inclusion required: (I) Meta-analyses or review articles; (II) adult patients aged 18 years or over undergoing alloplastic breast reconstruction; (III) studies including outcome measures; (IV) case series with more than 10 patients; (V) English language; and (VI) publication after 1st January, 2000. Results After full text review, analysis and data extraction was conducted for a total of 63 articles. Definitive reconstruction with an implant can be immediate or delayed. Older patients have similar or even lower complication rates to younger patients. Complications include capsular contracture, hematoma and infection. Obesity, smoking, large breasts, diabetes and higher grade tumors are associated with increased risk of wound problems and reconstructive failure. Silicone implant patients have higher capsular contracture rates but have higher physical and psychosocial function. There were no associations made between silicone implants and cancer or systemic disease. There were no differences in outcomes or complications between round and shaped implants. Textured implants have a lower risk of capsular contracture than smooth implants. Smooth implants are more likely to be displaced as well as having higher rates of infection. Immediate breast reconstruction (IBR) gives the best aesthetic outcome if radiotherapy is not required but has a higher rate of capsular contracture and implant failure. Delayed-immediate reconstruction patients can achieve similar aesthetic results to IBR whilst preserving the breast skin if radiotherapy is required. Delayed breast reconstruction (DBR) patients have fewer complications than IBR patients. Conclusions Implant reconstruction is a safe and popular mode of post-mastectomy reconstruction. Evidence exists for the settings in which complications are more likely, and we can now more reliably predict outcomes of reconstruction on an individual basis and assess patient suitability. PMID:27047785
Zafiropoulos, Gregor-Georg; John, Gordon
2017-05-01
The aim of this study was to determine the treatment outcome of the use of a porcine monolayer collagen matrix (mCM) to augment peri-implant soft tissue in conjunction with immediate implant placement as an alternative to patient's own connective tissue. A total of 27 implants were placed immediately in 27 patients (14 males and 13 females, with a mean age of 52.2 years) with simultaneous augmentation of the soft tissue by the use of a mCM. The patients were randomly divided into two groups: Group I: An envelope flap was created and mCM was left coronally uncovered, and group II: A coronally repositioned flap was created and the mCM was covered by the mucosa. Soft-tissue thickness (STTh) was measured at the time of surgery (T0) and 6 months postoperatively (T1) using a customized stent. Cone beam computed tomographies (CBCTs) were taken from 12 representative cases at T1. A stringent plaque control regimen was enforced in all the patients during the 6-month observation period. Mean STTh change was similar in both groups (0.7 ± 0.2 and 0.7 ± 0.1 mm in groups I and II respectively). The comparison of STTh between T0 and T1 showed a statistically significant increase of soft tissue in both groups I and II as well as in the total examined population (p < 0.001). The STTh change as well as matrix thickness loss were comparable in both groups (p > 0.05). The evaluation of the CBCTs did not show any signs of resorption of the buccal bone plate. Within the limitations of this study, it could be concluded that the collagen matrix used in conjunction with immediate implant placement leads to an increased thickness of peri-implant soft tissue independent of the flap creation technique and could be an alternative to connective tissue graft. The collagen matrix used seems to be a good alternative to patient's own connective tissue and could be used for the soft tissue augmentation around dental implants.
Walsh, W R; Svehla, M J; Russell, J; Saito, M; Nakashima, T; Gillies, R M; Bruce, W; Hori, R
2004-09-01
Implant surface roughness is an important parameter governing the overall mechanical properties at the implant-cement interface. This study investigated the influence of surface roughness using polymethylmethcrylate (PMMA) and a Bisphenol-a-glycidylmethacyrlate resin-hydroxyapatite cement (CAP). Mechanical fixation at the implant-cement interface was evaluated in vitro using static shear and fatigue loading with cobalt chrome alloy (CoCr) dowels with different surface roughness preparations. Increasing surface roughness improved the mechanical properties at the implant-cement interface for both types of cement. CAP cement fixation was superior to PMMA under static and dynamic loading.
McCullough, Jeffrey J; Klokkevold, Perry R
2017-10-01
Available literature suggests there is a transient drop in implant stability from approximately week 0 to week 3-4 as a result of peri-implant bone remodeling as it transitions from a primary, mechanical stability to a secondary, biological stability. Research investigating the influence of macro-thread design on this process is scant. The specific aim of this study was to evaluate the role of macro-thread design on implant stability in the early post-operative healing period using resonance frequency analysis (RFA). Seven patients, each missing at least two posterior teeth in the same arch, were included in the study. Three patients qualified for four implants resulting in a total of 10 matched pairs. All sites were healed (>6 months), non-grafted sites with sufficient bone to place implants. Each site in a matched pair was randomly assigned to receive either a control (Megagen EZ Plus Internal; EZ) or test (Megagen AnyRidge; AR) implant. The test implant incorporates a novel thread design with a wide thread depth and increased thread pitch. RFA was used to determine implant stability quotient (ISQ) values for each implant at the time of placement and weekly for the first 8 weeks. Implants consistently achieved a relatively high insertion torque (30-45 N/cm) and high initial ISQ value (79.8 ± 1.49). Baseline ISQ values for test (AR; 79.55 ± 1.61) and control (EZ; 80.05 ± 1.37) implants were similar. A general pattern of stability from baseline through all eight follow-up evaluations was observed for the test implants. A pattern of decreasing ISQ values was observed for the control implants across the early follow-up evaluations up to week four, where the value plateaued. There was a statistically significant main effect due to implant type (P < 0.01) and a statistically significant interaction between implant type and time (P < 0.01), indicating that the test and control implants performed differently at certain time points. Within the limitations of this study, macro-thread design appears to play a role in implant stability in the early post-operative healing period as assessed by RFA. These findings may have important implications related to immediate or early loading protocols. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Joda, Tim; Voumard, Benjamin; Zysset, Philippe K; Brägger, Urs; Ferrari, Marco
2018-04-01
The aims were to analyze stiffness, ultimate force, and failure modes of a 2-piece zirconium dioxide (ZrO 2 ) implant system. Eleven 2-piece ZrO 2 implants, each mounted with ZrO 2 abutments plus bonded monolithic lithium disilicate (LS 2 ) restorations, were grouped for 3.3mm (A) and 4.1mm (B) diameter samples. Quasi-static load was monotonically applied under a standardized test set-up (loading configuration according to DIN ISO 14801). The ultimate force was defined as the maximum force that implants are able to carry out until fracture; stiffness was measured as the maximum slope during loading. An unpaired t-test was performed between group A and B for ultimate force and stiffness (p<0.05). Force-displacement curves revealed statistically homogenous inner-group results for all samples. Failure modes showed characteristic fractures at the neck configuration of the implants independent of the diameter. Mean stiffness was 1099N/mm (±192) for group A, and significantly lower compared to group B with 1630N/mm (±274) (p<0.01); whereas mean ultimate force was 348N (±53) for group A, and significantly increased for group B with 684N (±29) (p<0.0001). The examined 2-piece ZrO 2 implant system mounted to LS 2 -restorations seems to be a stable unit under in-vitro conditions with mechanical properties compared to loading capacity of physiological force. The metal-free implant reconstructions demonstrated high stiffness and ultimate force under quasi-static load for single tooth replacement under consideration of the dental indication of narrow and standard diameter implants. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Clinical Management of Implant Prostheses in Patients with Bruxism
Komiyama, Osamu; Lobbezoo, Frank; De Laat, Antoon; Iida, Takashi; Kitagawa, Tsuyoshi; Murakami, Hiroshi; Kato, Takao; Kawara, Misao
2012-01-01
There is general agreement that excessive stress to the bone-implant interface may result in implant overload and failure. Early failure of the implant due to excessive loading occurs shortly after uncovering the implant. Excess load on a final restoration after successful implant integration can result in physical failure of the implant structure. Many clinicians believe that overload of dental implants is a risk factor for vertical peri-implant bone loss and/or may be detrimental for the suprastructure in implant prostheses. It has been documented that occlusal parafunction, such as, bruxism (tooth grinding and clenching) affects the outcome of implant prostheses, but there is no evidence for a causal relation between the failures and overload of dental implants. In spite of this lack of evidence, often metal restorations are preferred instead of porcelain for patients in whom bruxism is presumed on the basis of tooth wear. The purpose of this paper is to discuss the importance of the occlusal scheme used in implant restorations for implant longevity and to suggest a clinical approach and occlusal materials for implant prostheses in order to prevent complications related to bruxism. PMID:22701484
Maminskas, Julius; Puisys, Algirdas; Kuoppala, Ritva; Raustia, Aune; Juodzbalys, Gintaras
2016-01-01
To systematically review risks of mechanical impact on peri-implant strain and prosthetic influence on stability across finite element studies. An online literature search was performed on MEDLINE and EMBASE databases published between 2011 and 2016. Following keywords tiered screening and selection of the title, abstract and full-text were performed. Studies of finite element analysis (FEA) were considered for inclusion that were written in English and revealed stress concentrations or strain at peri-implant bone level. There were included 20 FEA studies in total. Data were organized according to the following topics: bone layers, type of bone, osseointegration level, bone level, design of implant, diameter and length of implant, implant-abutment connection, type of supra-construction, loading axis, measurement units. The stress or strain at implant-bone contact was measured over all studies and numerical values estimated. Risks of overloading were accented as non-axial loading, misfits, cantilevers and the stability of peri-implant bone was related with the usage of platform switch connection of abutment. Peri-implant area could be affected by non-axial loading, cantilever prosthetic elements, crown/implant ratio, type of implant-abutment connection, misfits, properties of restoration materials and antagonistic tooth. The heterogeneity of finite element analysis studies limits systematization of data. Results of these studies are comparable with other findings of in vitro , in vivo , prospective and retrospective studies.
A novel dynamic mechanical testing technique for reverse shoulder replacements.
Dabirrahmani, Danè; Bokor, Desmond; Appleyard, Richard
2014-04-01
In vitro mechanical testing of orthopedic implants provides information regarding their mechanical performance under simulated biomechanical conditions. Current in vitro component stability testing methods for reverse shoulder implants are based on anatomical shoulder designs, which do not capture the dynamic nature of these loads. With glenoid component loosening as one of the most prevalent modes of failure in reverse shoulder replacements, it is important to establish a testing protocol with a more realistic loading regime. This paper introduces a novel method of mechanically testing reverse shoulder implants, using more realistic load magnitudes and vectors, than is currently practiced. Using a custom made jig setup within an Instron mechanical testing system, it is possible to simulate the change in magnitude and direction of the joint load during arm abduction. This method is a step towards a more realistic testing protocol for measuring reverse shoulder implant stability.
Kempin, Wiebke; Franz, Christian; Koster, Lynn-Christine; Schneider, Felix; Bogdahn, Malte; Weitschies, Werner; Seidlitz, Anne
2017-06-01
The 3D printing technique of fused deposition modeling® (FDM) has lately come into focus as a potential fabrication technique for pharmaceutical dosage forms and medical devices that allows the preparation of delivery systems with nearly any shape. This is particular promising for implants administered at application sites with a high anatomical variability where an individual shape adaption appears reasonable. In this work different polymers (Eudragit®RS, polycaprolactone (PCL), poly(l-lactide) (PLLA) and ethyl cellulose (EC)) were evaluated with respect to their suitability for FDM of drug loaded implants and their drug release behaviour was evaluated. The fluorescent dye quinine was used as a model drug to visualize drug distribution in filaments and implants. Quinine loaded filaments were produced by solvent casting and subsequent hot melt extrusion (HME) and model implants were printed as hollow cylinders using a standard FDM printer. Parameters were found at which model implants (hollow cylinders, outer diameter 4-5mm, height 3mm) could be produced from all tested polymers. The drug release which was examined by incubation of the printed implants in phosphate buffered saline solution (PBS) pH 7.4 was highly dependent on the used polymer. The fastest relative drug release of approximately 76% in 51days was observed for PCL and the lowest for Eudragit®RS and EC with less than 5% of quinine release in 78 and 100days, respectively. For PCL further filaments were prepared with different quinine loads ranging from 2.5% to 25% and thermal analysis proved the presence of a solid dispersion of quinine in the polymer for all tested concentrations. Increasing the drug load also increased the overall percentage of drug released to the medium since nearly the same absolute amount of quinine remained trapped in PCL at the end of drug release studies. This knowledge is valuable for future developments of printed implants with a desired drug release profile that might be controlled by the choice of the polymer and the drug load. Copyright © 2017 Elsevier B.V. All rights reserved.
Park, Ji-Man; Baek, Chang-Hyun; Heo, Seong-Joo; Kim, Seong-Kyun; Koak, Jai-Young; Kim, Shin-Koo; Belser, Urs C
The aim of this study was to compare the loosening of interchangeable one-piece abutments connected to internal-connection-type implants after cyclic loading. Four implant abutment groups (n = 7 in each group) with Straumann tissue-level implants were assessed: Straumann solid abutment (group S), Southern Implants solid abutment (group SI), Implant Direct straight abutment (group ID), and Blue Sky Bio regular platform abutment (group BSB). The implant was firmly held in a special jig to ensure fixation. Abutment screws were tightened to manufacturers' recommended torque with a digital torque gauge. The hemispherical loading members were fabricated for the load cell of a universal testing machine to evenly distribute the force on the specimens and to fulfill the ISO 14801:2007 standard. A cyclic loading of 25 N at 30 degrees to the implant's long axis was applied for a duty of a half million cycles. Tightening torques were measured prior to the loading. Removal torques were measured after cyclic loading. The data were analyzed with one-way analysis of variance (ANOVA), and the significance level was set at P < .05. The mean removal torques after cyclic loading were 34.0 ± 1.1 Ncm (group S), 25.0 ± 1.5 Ncm (group SI), 23.9 ± 2.1 Ncm (group ID), and 27.9 ± 1.3 Ncm (group BSB). Removal torques of each group were statistically different in the order of group S > group BSB > groups SI and ID (P < .05). The mean reduction rates were -2.9% ± 3.2% (group S), -21.9% ± 4.8% (group SI), -20.2% ± 7.2% (group ID), and -6.9% ± 4.3% (group BSB) after a half million cycles, respectively. Reduction rates of groups S and BSB were statistically lower than those of groups SI and ID (P < .01). The standard deviation of group S was lower than group BSB. The removal torque of the original Straumann abutment was significantly higher than those of the copy abutments. The reduction rate of the groups S and BSB abutments was lower than those of the other copy abutments.
Dittmer, Marc Philipp; Nensa, Moritz; Stiesch, Meike; Kohorst, Philipp
2013-01-01
Implant-supported screw-retained fixed dental prostheses (FDPs) produced by CAD/ CAM have been introduced in recent years for the rehabilitation of partial or total endentulous jaws. However, there is a lack of data about the long-term mechanical characteristics. The aim of this study was to investigate the failure mode and the influence of extended cyclic mechanical loading on the load-bearing capacity of these frameworks. Ten five-unit FDP frameworks simulating a free-end situation in the mandibular jaw were manufactured according to the I-Bridge®2-concept (I-Bridge®2, Biomain AB, Helsingborg, Sweden) and each was screw-retained on three differently angulated Astra Tech implants (30º buccal angulation/0º angulation/30º lingual angulation). One half of the specimens was tested for static load-bearing capacity without any further treatment (control), whereas the other half underwent five million cycles of mechanical loading with 100 N as the upper load limit (test). All specimens were loaded until failure in a universal testing machine with an occlusal force applied at the pontics. Load-displacement curves were recorded and the failure mode was macro- and microscopically analyzed. The statistical analysis was performed using a t-test (p=0.05). All the specimens survived cyclic mechanical loading and no obvious failure could be observed. Due to the cyclic mechanical loading, the load-bearing capacity decreased from 8,496 N±196 N (control) to 7,592 N±901 N (test). The cyclic mechanical loading did not significantly influence the load-bearing capacity (p=0.060). The failure mode was almost identical in all specimens: large deformations of the framework at the implant connection area were obvious. The load-bearing capacity of the I-Bridge®2 frameworks is much higher than the clinically relevant occlusal forces, even with considerably angulated implants. However, the performance under functional loading in vivo depends on additional aspects. Further studies are needed to address these aspects.
DITTMER, Marc Philipp; NENSA, Moritz; STIESCH, Meike; KOHORST, Philipp
2013-01-01
Implant-supported screw-retained fixed dental prostheses (FDPs) produced by CAD/ CAM have been introduced in recent years for the rehabilitation of partial or total endentulous jaws. However, there is a lack of data about the long-term mechanical characteristics. Objective The aim of this study was to investigate the failure mode and the influence of extended cyclic mechanical loading on the load-bearing capacity of these frameworks. Material and Methods Ten five-unit FDP frameworks simulating a free-end situation in the mandibular jaw were manufactured according to the I-Bridge®2-concept (I-Bridge®2, Biomain AB, Helsingborg, Sweden) and each was screw-retained on three differently angulated Astra Tech implants (30º buccal angulation/0º angulation/30º lingual angulation). One half of the specimens was tested for static load-bearing capacity without any further treatment (control), whereas the other half underwent five million cycles of mechanical loading with 100 N as the upper load limit (test). All specimens were loaded until failure in a universal testing machine with an occlusal force applied at the pontics. Load-displacement curves were recorded and the failure mode was macro- and microscopically analyzed. The statistical analysis was performed using a t-test (p=0.05). Results All the specimens survived cyclic mechanical loading and no obvious failure could be observed. Due to the cyclic mechanical loading, the load-bearing capacity decreased from 8,496 N±196 N (control) to 7,592 N±901 N (test). The cyclic mechanical loading did not significantly influence the load-bearing capacity (p=0.060). The failure mode was almost identical in all specimens: large deformations of the framework at the implant connection area were obvious. Conclusion The load-bearing capacity of the I-Bridge®2 frameworks is much higher than the clinically relevant occlusal forces, even with considerably angulated implants. However, the performance under functional loading in vivo depends on additional aspects. Further studies are needed to address these aspects. PMID:24037068
Marković, Aleksa; Calvo-Guirado, José Luís; Lazić, Zoran; Gómez-Moreno, Gerardo; Ćalasan, Dejan; Guardia, Javier; Čolic, Snježana; Aguilar-Salvatierra, Antonio; Gačić, Bojan; Delgado-Ruiz, Rafael; Janjić, Bojan; Mišić, Tijana
2013-06-01
The aim of this study was to investigate the relationship between surgical techniques and implant macro-design (self-tapping/non-self-tapping) for the optimization of implant stability in the low-density bone present in the posterior maxilla using resonance frequency analysis (RFA). A total of 102 implants were studied. Fifty-six self-tapping BlueSkyBredent® (Bredent GmbH&Co.Kg®, Senden, Germany) and 56 non-self-tapping Standard Plus Straumann® (Institut Straumann AG®, Waldenburg, Switzerland) were placed in the posterior segment of the maxilla. Implants of both types were placed in sites prepared with either lateral bone-condensing or with bone-drilling techniques. Implant stability measurements were performed using RFA immediately after implant placement and weekly during a 12-week follow-up period. Both types of implants placed after bone condensing achieved significantly higher stability immediately after surgery, as well as during the entire 12-week observation period compared with those placed following bone drilling. After bone condensation, there were no significant differences in primary stability or in implant stability after the first week between both implant types. From 2 to 12 postoperative weeks, significantly higher stability was shown by self-tapping implants. After bone drilling, self-tapping implants achieved significantly higher stability than non-self-tapping implants during the entire follow-up period. The outcomes of the present study indicate that bone drilling is not an effective technique for improving implant stability and, following this technique, the use of self-tapping implants is highly recommended. Implant stability optimization in the soft bone can be achieved by lateral bone-condensing technique, regardless of implant macro-design. © 2011 Wiley Periodicals, Inc.
Modular adaptive implant based on smart materials.
Bîzdoacă, N; Tarniţă, Daniela; Tarniţă, D N
2008-01-01
Applications of biological methods and systems found in nature to the study and design of engineering systems and modern technology are defined as Bionics. The present paper describes a bionics application of shape memory alloy in construction of orthopedic implant. The main idea of this paper is related to design modular adaptive implants for fractured bones. In order to target the efficiency of medical treatment, the implant has to protect the fractured bone, for the healing period, undertaking much as is possible from the daily usual load of the healthy bones. After a particular stage of healing period is passed, using implant modularity, the load is gradually transferred to bone, assuring in this manner a gradually recover of bone function. The adaptability of this design is related to medical possibility of the physician to made the implant to correspond to patient specifically anatomy. Using a CT realistic numerical bone models, the mechanical simulation of different types of loading of the fractured bones treated with conventional method are presented. The results are commented and conclusions are formulated.
Carbon and metal-carbon implantations into tool steels for improved tribological performance
NASA Astrophysics Data System (ADS)
Hirvonen, J.-P.; Harskamp, F.; Torri, P.; Willers, H.; Fusari, A.; Gibson, N.; Haupt, J.
1997-05-01
The high-fluence implantation of carbon and dual implantations of metal-metalloid pairs into steels with different microstructures are briefly reviewed. A previously unexamined system, the implantation of Si and C into two kinds of tool steels, M3 and D2, have been studied in terms of microstructure and tribological performance. In both cases ion implantation transfers a surface into an amorphous layer. However, the tribological behavior of these two materials differs remarkably: in the case of ion-implanted M3 a reduction of wear in a steel pin is observed even at high pin loads, whereas in the case of ion-implanted D2 the beneficial effects of ion implantation were limited to the lowest pin load. The importance of an initial phase at the onset of sliding is emphasized and a number of peculiarities observed in ion-implanted M3 steel are discussed.
Termeie, Deborah; Klokkevold, Perry R; Caputo, Angelo A
2015-10-01
The long-term clinical success of a dental implant is dependent upon maintaining sufficient osseointegration to resist forces of occlusion. The purpose of this study was to investigate the effect of implant diameter on stress distribution around screw-type dental implants in mandibular first molar sites using photoelastic models. The design included models with different buccal-lingual dimension. Twelve composite photoelastic models were assembled using 2 different resins to simulate trabecular and cortical bone. Half of the models were fabricated with average dimensions for ridge width and the other half with narrower buccal-lingual dimensions. One internal connection implant (13 mm length) with either a standard (4 mm), wide (5 mm), or narrow (3.3 mm) diameter was embedded in the first molar position of each photoelastic model. Half the implants were tapered and the other half were straight. Full gold crowns in the shape of a mandibular first molar were fabricated and attached to the implants. Vertical and angled loads of 15 and 30 pounds were applied to specific points on the crown. Wide-diameter implants produced the least stress in all ridges while narrow-diameter implants generated the highest stress, especially in narrow ridges. It may be that the volume and quality of bone surrounding implants influences stress distribution with a greater ratio of cortical to trabecular bone, thus providing better support. Models with wide-diameter implants loaded axially had a more symmetrical stress distribution compared to standard and narrow diameter implants. A more asymmetrical stress pattern developed along the entire implant length with angled loads. Implant diameter and ridge width had considerable influence on stress distribution. Narrow-diameter implants produced more stress than wide diameter implants in all conditions tested.
Effect of radial head implant shape on joint contact area and location during static loading.
Shannon, Hannah L; Deluce, Simon R; Lalone, Emily A; Willing, Ryan; King, Graham J W; Johnson, James A
2015-04-01
To examine the effect of implant shape on radiocapitellar joint contact area and location in vitro. We used 8 fresh-frozen cadaveric upper extremities. An elbow loading simulator examined joint contact in pronation, neutral rotation, and supination with the elbow at 90° flexion. Muscle tendons were attached to pneumatic actuators to allow for computer-controlled loading to achieve the desired forearm rotation. We performed testing with the native radial head, an axisymmetric implant, a reverse-engineered patient-specific implant, and a population-based quasi-anatomic implant. Implants were inserted using computer navigation. Contact area and location were quantified using a casting technique. We found no significant difference between contact locations for the native radial head and the 3 implants. All of the implants had a contact area lower than the native radial head; however, only the axisymmetric implant was significantly different. There was no significant difference in contact area between implant shapes. The similar contact areas and locations of the 3 implant designs suggest that the shape of the implant may not be important with respect to radiocapitellar joint contact mechanics when placed optimally using computer navigation. Further work is needed to explore the sensitivity of radial head implant malpositioning on articular contact. The lower contact area of the radial head implants relative to the native radial head is similar to previous benchtop studies and is likely the result of the greater stiffness of the implant. Radial head implant shape does not appear to have a pronounced influence on articular contact, and both axisymmetric and anatomic metal designs result in elevated cartilage stress relative to the intact state. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Farrell, Brad J; Prilutsky, Boris I; Kistenberg, Robert S; Dalton, John F; Pitkin, Mark
2014-01-01
Background Despite the number of advantages of bone-anchored prostheses, their use in patients is limited due to the lack of complete skin-implant integration. The objective of the present study was to develop an animal model that would permit both detailed investigations of gait with a bone-anchored limb prosthesis and histological analysis of the skin-implant-bone interface after physiological loading of the implant during standing and walking. Methods Full-body mechanics of walking in two cats was recorded and analyzed before and after implantation of a percutaneous porous titanium pylon into the right tibia and attachment of a prosthesis. The rehabilitation procedures included initial limb casting, progressively increasing loading of implant, and standing and locomotor training. Detailed histological analysis of bone and skin ingrowth into implant was performed at the end of the study. Findings The two animals adopted the bone-anchored prosthesis for standing and locomotion, although loads on the prosthetic limb during walking decreased by 22% and 62%, respectively, 4 months after implantation. The animals shifted body weight to the contralateral side and increased propulsion forces by the contralateral hindlimb. Histological analysis of the limb implants demonstrated bone and skin ingrowth. Interpretation The developed animal model to study prosthetic gait and tissue integration with the implant demonstrated that porous titanium implants may permit bone and skin integration and prosthetic gait with a prosthesis. Future studies with this model will help optimize the implant and prosthesis properties. PMID:24405567
Şener-Yamaner, Işil Damla; Yamaner, Gökhan; Sertgöz, Atilla; Çanakçi, Cenk Fatih; Özcan, Mutlu
2017-08-01
The aim of this study was to compare marginal bone loss around early-loaded SLA and SLActive tissue-level implants (Straumann Dental Implants; Institut Straumann AG, Basel, Switzerland) after a mean of 81-month follow-up period. One hundred seven SLA and 68 SLActive implants were placed in 55 patients and loaded with final restoration after 8 and 3 weeks of healing time, respectively. Marginal bone loss around implants was determined radiographically at initial and after a mean observation time ranging between 20 and 81 months. The effect of location (mandible vs maxilla), smoking habit, sex, implant length and diameter, and the type of prosthesis on the marginal bone loss was evaluated. The overall cumulative survival rate was 98.2% being 99% for SLA implants and 97% for SLActive implants. After 20-month follow-up period, mean marginal bone loss values for the SLA and SLActive implants were 0.24 and 0.17 mm, respectively. After 81 months, mean marginal bone loss for the SLA and SLActive implants reached 0.71 and 0.53 mm, respectively. Marginal bone loss was affected by the length and type of implant and patients' smoking habit after a mean observation time of 20 months. However, none of the parameters had any significant effect on the marginal bone loss after a follow-up period of 81 months. With both SLA and SLActive implants, successful clinical results could be achieved up to 6.5 years of follow-up period.
R&D on dental implants breakage
NASA Astrophysics Data System (ADS)
Croitoru, Sorin Mihai; Popovici, Ion Alexandru
2017-09-01
Most used dental implants for human dental prostheses are of two steps type: first step means implantation and, after several months healing and osseointegration, second step is prosthesis fixture. For sure, dental implants and prostheses are meant to last for a lifetime. Still, there are unfortunate cases when dental implants break. This paper studies two steps dental implants breakage and proposes a set of instruments for replacement and restoration of the broken implant. First part of the paper sets the input data of the study: structure of the studied two steps dental implants based on two Romanian patents and values of the loading forces found in practice and specialty papers. In the second part of the paper, using DEFORM 2D™ FEM simulation software, worst case scenarios of loading dental implants are studied in order to determine which zones and components of the dental implant set are affected (broken). Last part of the paper is dedicated to design and presentation of a set for extracting and cutting tools used to restore the broken implant set.
Nishioka, Renato Sussumu; Rodrigues, Vinicius Anéas; De Santis, Leandro Ruivo; Nishioka, Gabriela Nogueira De Melo; Santos, Vivian Mayumi Miyazaki; Souza, Francisley Ávila
2016-02-01
To quantify microstrain development during axial loading using strain gauge analysis for short implants, varying the type of fixture-abutment joint and thread design. An internal hexagon implant (4 × 8 mm) and a plateau design implant (4 × 8 mm) were embedded on the center of 10 polyurethane blocks with dimensions of 190 × 30 × 12 mm. The respective abutments were screwed onto the implants. Four strain gauges (SGs) were bonded onto the surface of each block, and 4 vertical SGs were bonded onto the side of each block. Axial load of 30 kgf was applied for 10 seconds in the center of each implant. The data were analyzed statistically by analysis of variance for repeated measures and Tukey test (P < 0.05). The interaction between implant and region factors have been statistically significant (P = 0.0259). Tukey test revealed a difference on plateau's horizontal region. The cervical region presented higher microstrain values, when compared with the medium and apical regions of the implants. Within the purpose of the study, the type of fixture-abutment joint is a relevant factor to affect the amount of stress/strain in bone simulation. The microstrain development was concentrated on the cervical region of the implant.
Schormans, Matthew; Valente, Virgilio; Demosthenous, Andreas
2016-08-04
Inductive powering for implanted medical devices, such as implantable biosensors, is a safe and effective technique that allows power to be delivered to implants wirelessly, avoiding the use of transcutaneous wires or implanted batteries. Wireless powering is very sensitive to a number of link parameters, including coil distance, alignment, shape, and load conditions. The optimum drive frequency of an inductive link varies depending on the coil spacing and load. This paper presents an optimum frequency tracking (OFT) method, in which an inductive power link is driven at a frequency that is maintained at an optimum value to ensure that the link is working at resonance, and the output voltage is maximised. The method is shown to provide significant improvements in maintained secondary voltage and system efficiency for a range of loads when the link is overcoupled. The OFT method does not require the use of variable capacitors or inductors. When tested at frequencies around a nominal frequency of 5 MHz, the OFT method provides up to a twofold efficiency improvement compared to a fixed frequency drive. The system can be readily interfaced with passive implants or implantable biosensors, and lends itself to interfacing with designs such as distributed implanted sensor networks, where each implant is operating at a different frequency.
Echazarreta-Gallego, Estíbaliz; Pola-Bandrés, Guillermo; Arribas-Del Amo, María Dolores; Gil-Romea, Ismael; Sousa-Domínguez, Ramón; Güemes-Sánchez, Antonio
2017-10-01
Breast prostheses exposure is probably the most devastating complication after a skin sparing mastectomy (SSM) and implant-based, one-stage, breast reconstruction. This complication may occur in the immediate post-operative period or in the weeks and even months after the procedure. In most cases, the cause is poor skin coverage of the implant due to skin necrosis. Eight consecutive cases of implant exposure (or risk of exposure) due to skin necrosis in SSM patients over a period of 5 years, all patients were treated using a random epigastric rotation flap, executed by the same medical team. A random epigastric flap (island or conventional rotation flap) was used to cover the skin defect. All the patients completed the procedure and all prostheses were saved; there were no cases of flap necrosis or infection. Cases of skin necrosis after SSM and immediate implant reconstruction, in which the implant is at risk of exposure, can be successfully treated with a random epigastric rotation flap.
Okumoto, T; Koike, G; Yoshimura, Y
2014-03-01
A mobile eye socket is generally reconstructed by inserting an implant into the scleral pocket immediately after bulbar exenteration, or by attaching the extra-ocular muscles to the implanted artificial eyeball immediately after enucleation. However, exposure of the implanted material and other problems can occur. We achieved satisfactory reconstruction of a mobile eye socket by using an autogenous cartilage graft and a pericranial flap in a patient with long-standing anophthalmia due to enucleation. This case is presented with a review of the relevant literature. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Immediate breast reconstruction using autologous skin graft associated with breast implant.
Dutra, A K; Andrade, W P; Carvalho, S M T; Makdissi, F B A; Yoshimatsu, E K; Domingues, M C; Maciel, M S
2012-02-01
Immediate breast reconstruction with skin graft is still little mentioned in the literature. Follow-up studies regarding the technique aspects are particularly scarce. The objective was to detail immediate breast reconstruction using autologous skin graft. Patients (n = 49) who underwent mastectomies and autologous immediate breast reconstruction with skin graft associated with a breast implant at A. C. Camargo Hospital (São Paulo, Brazil) between January 2007 and July 2010 were included. Information on clinical data, technique details and clinical outcome were prospectively collected. Following mastectomy, the autologous full-thickness skin graft was obtained through an inframammary fold incision along the contralateral breast in most patients. The skin graft was placed on the surface of the pectoralis major muscle after adjustments to conform to the mastectomy defect. A minimum of 10-month follow-up period was established. Patients' age ranged from 35 to 55 years and all received a silicone gel textured surface implant to obtain the necessary breast mound. The mean surgical time was 45 min, and the mean amount of skin resection was 4.5 cm in the largest diameter. Follow-up ranged from 10 to 35 months (median 23). All patients had silicone-gel textured surface implants to perform the breast mound reconstruction. No complications were observed in 87.8% of reconstructions. Forty-six patients (94%) had no complaints about the donor-site aesthetics. The result was a breast mound with a central ellipse of healed skin graft. Three (6%) poor results were observed. Thirty-six patients (67%) reported the results as good or very good. Our results lead us to conclude that autologous skin graft provided a reliable option in immediate breast reconstruction to skin-sparing mastectomy defects. The technique accomplished a single-stage implant breast reconstruction when there is inadequate skin coverage. Copyright © 2011 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Petsinis, Vassilis; Kamperos, Georgios; Alexandridi, Foteini; Alexandridis, Konstantinos
2017-08-01
To evaluate the impact of glucocorticosteroids, administered for the treatment of systemic diseases, on the osseointegration and survival of dental implants placed without bone grafting. A retrospective study was conducted in search of patients treated with dental implants while receiving glucocorticosteroid therapy for various systemic diseases. In these cases, a conventional two-stage surgical protocol was used, without bone regeneration procedures. The osseointegration was clinically and radiographically tested at the uncovering of the implants. The follow-up after loading was set at a minimum of 3 years. A total of 31 patients were included in the study. Of the 105 dental implants placed, 104 were osseointegrated (99%). No bone absorption was radiographically noted at the uncovering of the osseointegrated implants. All of the osseointegrated implants were successfully loaded for the prosthetic restoration. The mean follow-up period after loading was 71 months, with an implant survival rate of 99%. Glucocorticosteroid intake for systemic diseases does not have a significant impact on the osseointegration and the 3-year survival of dental implants placed with a conventional two-stage surgical protocol and without bone grafting. Therefore, it should not be considered a contraindication for dental implant placement. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Clinical application of micro-implant anchorage in initial orthodontic retraction.
Wahabuddin, Shaji; Mascarenhas, Rohan; Iqbal, Mahamad; Husain, Akhter
2015-02-01
Micro-implant is a device that is temporarily fixed to bone for the purpose of enhancing orthodontic anchorage either by supporting the teeth of the reactive unit or by obviating the need for the reactive unit altogether, and which is subsequently removed after use. The purpose of this study was to evaluate the clinical efficiency of micro-implants in reinforcing anchorage during the initial retraction of anterior teeth, check the rate of initial retraction for 8 weeks, and assess the stability of micro-implants during this period. Eighteen micro-implants were placed (10 in the maxilla and 8 in the mandible) and immediately loaded with 200-250 g of force using 9-mm closed coil Nitinol springs. The amount of space closure was measured every 2 weeks until the eighth week. Cephalometric measurements were made at the end of the study to evaluate anchor loss, if any. Micro-implant stability was also assessed. The rate of initial retraction in the maxilla at the end of 8 weeks was 1.65 mm/quadrant and 1.51 mm/quadrant in the mandible. The amount of retraction on the left side of the arches was 1.66 mm/quadrant and 1.49 mm/quadrant on the right side. The average initial retraction for both arches per month was 0.78 mm. An anchor loss of 0.1 mm (0.06%) was observed in the maxilla while no mandibular anchor loss was recorded. The rate of initial retraction observed in the maxilla was more than that achieved in the mandible. Initial retraction was also more on the left side of the arches. There was no anchor loss in the mandible. The micro-implant-reinforced anchorage was helpful in minimizing anchor loss and accepted heavy traction forces but did not bring about a faster rate of retraction.
Stimmelmayr, Michael; Edelhoff, Daniel; Güth, Jan-Frederik; Erdelt, Kurt; Happe, Arndt; Beuer, Florian
2012-12-01
The purpose of this study was to determine and measure the wear of the interface between titanium implants and one-piece zirconia abutments in comparison to titanium abutments. 6 implants were secured into epoxy resin blocks. The implant interface of these implants and 6 corresponding abutments (group Zr: three one-piece zirconia abutments; group Ti: three titanium abutments) were examined by a microscope and scanning electron micrograph (SEM). Also the implants and the abutments were scanned by 3D-Micro Computer Tomography (CT). The abutments were connected to the implants and cyclically loaded with 1,200,000 cycles at 100N in a two-axis fatigue testing machine. Afterwards, all specimens were unscrewed and the implants and abutments again were scanned by microscope, SEM and CT. The microscope and SEM images were compared, the CT data were superimposed and the wear was calculated by inspection software. The statistical analysis was carried out with an unpaired t-test. Abutment fracture or screw loosening was not observed during cyclical loading. Comparing the microscope and SEM images more wear was observed on the implants connected to zirconia abutments. The maximum wear on the implant shoulder calculated by the inspection software was 10.2μm for group Zr, and 0.7μm for group Ti. The influence of the abutment material on the measured wear was statistically significant (p≤0.001; Levene-test). Titanium implants showed higher wear at the implant interface following cyclic loading when connected to one-piece zirconia implant abutments compared to titanium abutments. The clinical relevance is not clear; hence damage of the internal implant connection could result in prosthetic failures up to the need of implant removal. Copyright © 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Finite element analysis of stress-breaking attachments on maxillary implant-retained overdentures.
Tanino, Fuminori; Hayakawa, Iwao; Hirano, Shigezo; Minakuchi, Shunsuke
2007-01-01
The purpose of this study was to examine the effect of stress-breaking attachments at the connections between maxillary palateless overdentures and implants. Three-dimensional finite element models were used to reproduce an edentulous human maxilla with an implant-retained overdenture. Two-implant models (in the canine tooth positions on both sides) and four-implant models (in the canine and second premolar tooth positions on both sides) were examined. Stress-breaking material connecting the implants and denture was included around each abutment. Axial loads of 100 N were applied to the occlusal surface at the left first molar tooth positions. In each model, the influence of the stress-breaking attachments was compared by changing the elastic modulus from 1 to 3,000 MPa and the thickness of the stress-breaking material from 1 to 3 mm. Maximum stress at the implant-bone interface and stress at the cortical bone surface just under the loading point were calculated. In all models, maximum stress at the implant-bone interface with implants located in the canine tooth position was generated at the peri-implant bone on the loading side. As the elastic modulus of the stress-breaking materials increased, the stress increased at the implant-bone interface and decreased at the cortical bone surface. Moreover, stress at the implant-bone interface with 3-mm-thick stress-breaking material was smaller than that with 1-mm-thick material. Within the limitations of this experiment, stress generated at the implant-bone interface could be controlled by altering the elastic modulus and thickness of the stress-breaking materials.
Soğancı, Gökçe; Yazıcıoğlu, Hüseyin
2016-01-01
Mini dental implants could be an alternative treatment method for prosthetic treatment of edentulous cleft palate. The aim of this study was to analyze stress distribution around the cortical bone and different plans using a varied number of mini dental implants in edentulous unilateral complete cleft palates. Three edentulous maxillary models were modified to create unilateral complete cleft palates. Mini dental implants (2.4 × 15 mm) were located as two mini implants at the premolar region, four mini implants at the premolar and molar region, and six mini implants at the first premolar, second premolar, and first molar regions in the models, respectively. Mucosa, o-ring/ball attachments, and overdentures were simulated. Vertical and horizontal loads of 100 N were applied on both the right and left molar teeth of the overdenture for each model. Maximum and minimum principal stress values and the distribution at cortical bone around the implants and cleft palates were evaluated by finite element analysis. Stress values under vertical loads were lower than values under horizontal loadings for all models. Stress values were found to be lower in the first model than in the second and third models. The highest stress values were found around implants in the second model. The unilateral feature of a complete cleft pattern affected the stress distribution. Stresses occured mostly around implants when the overdenture was supported by six implants; however, the stress distribution around implants was low with two implants because of tissue support.
Conductive polymer sensor arrays for smart orthopaedic implants
NASA Astrophysics Data System (ADS)
Micolini, Carolina; Holness, F. B.; Johnson, James A.; Price, Aaron D.
2017-04-01
This study proposes and demonstrates the design, implementation, and characterization of a 3D-printed smartpolymer sensor array using conductive polyaniline (PANI) structures embedded in a polymeric substrate. The piezoresistive characteristics of PANI were studied to evaluate the efficacy of the manufacturing of an embedded pressure sensor. PANI's stability throughout loading and unloading cycles together with the response to incremental loading cycles was investigated. It is demonstrated that this specially developed multi-material additive manufacturing process for polyaniline is a good candidate for the manufacture of implant components with smart-polymer sensors embedded for the analysis of joint loads in orthopaedic implants.
Microleakage Evaluation at Implant-Abutment Interface Using Radiotracer Technique
Siadat, Hakimeh; Arshad, Mahnaz; Mahgoli, Hossein-Ali; Fallahi, Babak
2016-01-01
Objectives: Microbial leakage through the implant-abutment (I-A) interface results in bacterial colonization in two-piece implants. The aim of this study was to compare microleakage rates in three types of Replace abutments namely Snappy, GoldAdapt, and customized ceramic using radiotracing. Materials and Methods: Three groups, one for each abutment type, of five implants and one positive and one negative control were considered (a total of 17 regular body implants). A torque of 35 N/cm was applied to the abutments. The samples were immersed in thallium 201 radioisotope solution for 24 hours to let the radiotracers leak through the I-A interface. Then, gamma photons received from the radiotracers were counted using a gamma counter device. In the next phase, cyclic fatigue loading process was applied followed by the same steps of immersion in the radioactive solution and photon counting. Results: Rate of microleakage significantly increased (P≤0.05) in all three types of abutments (i.e. Snappy, GoldAdapt, and ceramic) after cyclic loading. No statistically significant differences were observed between abutment types after cyclic loading. Conclusions: Microleakage significantly increases after cyclic loading in all three Replace abutments (GoldAdapt, Snappy, ceramic). Lowest microleakage before and after cyclic loading was observed in GoldAdapt followed by Snappy and ceramic. PMID:28392814
Tazin, I D; Sysoliatin, P G; Panov, L A; Giunter, V E
2000-01-01
Use of titanium nickelide based porous permeable implants for repair of postosteomyelitis mandibular defects is discussed. Five patients with mandibular defects of different location and extent were operated on. Surgical methods are described. A clinical example of using a porous permeable implant is offered. The implant designed as a mandible was used for repair of an extensive mandibular defect. Good immediate and remote results of operations indicate good prospects of using such implants.
Kohal, Ralf-Joachim; Kilian, Jolanta Bernadette; Stampf, Susanne; Spies, Benedikt Christopher
2015-01-01
The aim of the current investigation was to evaluate the fracture resistance of one-piece zirconia oral implants with and without all-ceramic incisor crowns after long-term thermomechanical cycling. A total of 48 implants were evaluated. The groups with crowns (C, 24 samples) and without crowns (N, 24 samples) were subdivided according to the loading protocol, resulting in three groups of 8 samples each: Group “0” was not exposed to cyclic loading, whereas groups “5” and “10” were loaded with 5 and 10 million chewing cycles, respectively. This resulted in 6 different groups: C0/N0, C5/N5 and C10/N10. Subsequently, all 48 implants were statically loaded to fracture and bending moments were calculated. All implants survived the artificial aging. For the static loading the following average bending moments were calculated: C0: 326 Ncm; C5: 339 Ncm; C10: 369 Ncm; N0: 339 Ncm; N5: 398 Ncm and N10: 355 Ncm. To a certain extent, thermomechanical cycling resulted in an increase of fracture resistance which did not prove to be statistically significant. Regarding its fracture resistance, the evaluated ceramic implant system made of Y-TZP seems to be able to resist physiological chewing forces long-term. Restauration with all-ceramic single crowns showed no negative influence on fracture resistance. PMID:28788018
Tokar, Emre; Uludag, Bulent; Karacaer, Ozgul
Implant-retained overdentures are the first choice of rehabilitation for edentulous mandibles. Bone morphology and anatomical landmarks may be influenced by the location and angulation of implants and distances between the implants. The purpose of this study was to investigate stress distribution characteristics and to compare stress levels of three different attachment designs of three-implant-retained mandibular overdentures with three different interimplant distances. Three photoelastic mandibular models with three implants were fabricated using an edentulous mandible cast with moderate residual ridge resorption. The center implants were embedded parallel to the midline, and the distal implants were aligned at a 20-degree angulation corresponding to the center implants. Distances between the center and distal implants were set at 11, 18, and 25 mm at the photoelastic models. Bar, bar-ball, and Locator attachment-retained overdentures were prepared for the models. Vertical loads were applied to the overdentures, and stress levels and distribution were evaluated by a circular polariscope. The greatest observed stress level was moderate for the tested overdenture designs. The Locator attachment system showed the lowest stress level for the 11-mm and 25-mm photoelastic models. The bar attachment design transmitted less stress compared with the other tested designs for the 18-mm photoelastic model. Stresses were observed on the loaded side of the photoelastic models. The lowest stress was found with the Locator and bar attachments for the 11-mm photoelastic model, which transmitted little or no discernible stress around the implants.
Groenendijk, E; Staas, T A; Graauwmans, F E J; Bronkhorst, E; Verhamme, L; Maal, T; Meijer, G J
2017-12-01
This retrospective study aimed to analyse the fate of the buccal crest after immediate implant placement (IIP) through the use of cone beam computed tomography (CBCT). In 16 consecutive patients, an implant was placed in a more palatal position after extraction, thereby creating a gap of at least 2mm between the implant and the buccal crest. Subsequently, this gap was filled with a bone substitute. Preoperatively, immediate postoperatively, and late postoperatively, a CBCT was made to measure the thickness of the buccal crest. After application of the bone substitute, the buccal crest increased in thickness from 0.9mm to 2.4mm (mean). At a mean of 103 weeks after IIP, late postoperative CBCT scans showed that the thickness of the buccal crest was compacted to 1.8mm. In the same period, the height of the buccal crest increased by 1.6mm (mean) to, on average, 1.2mm above the implant shoulder. The aesthetic outcome was analysed using the White and Pink Esthetic Score (WES and PES). Both scored high: 8.4 and 11.8, respectively. Within the limitations of this study, the results of this IIP protocol are promising. Long-term prospective research on this topic on a large number of patients is necessary. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Esposito, Marco; Pellegrino, Gerardo; Pistilli, Roberto; Felice, Pietro
2011-01-01
To evaluate whether 5 mm short dental implants could be an alternative to augmentation with anorganic bovine bone and placement of at least 10 mm long implants in posterior atrophic jaws. Fifteen patients with bilateral atrophic mandibles (5-7 mm bone height above the mandibular canal), and 15 patients with bilateral atrophic maxillae (4-6 mm bone height below the maxillary sinus) and bone thickness of at least 8 mm, were randomised according to a splitmouth design to receive one to three 5 mm short implants or at least 10 mm long implants in augmented bone. Mandibles were vertically augmented with interpositional bone blocks and maxillary sinuses with particulated bone via a lateral window. Implants were placed after 4 months, submerged and loaded, after 4 months, with provisional prostheses. Four months later, definitive provisionally cemented prostheses were delivered. Outcome measures were: prosthesis and implant failures, any complication and peri-implant marginal bone level changes. In 5 augmented mandibles, the planned 10 mm long implants could not be placed and shorter implants (7 and 8.5 mm) had to be used instead. One year after loading no patient dropped out. Two long (8.5 mm in the mandible and 13 mm in the maxilla) implants and one 5 mm short maxillary implant failed. There were no statistically significant differences in failures or complications. Patients with short implants lost on average 1 mm of peri-implant bone and patients with longer implants lost 1.2 mm. This difference was statistically significant. This pilot study suggests that 1 year after loading, 5 mm short implants achieve similar if not better results than longer implants placed in augmented bone. Short implants might be a preferable choice to bone augmentation since the treatment is faster, cheaper and associated with less morbidity, however their long-term prognosis is unknown.
Alsabeeha, Nabeel H M; Payne, Alan G T; De Silva, Rohana K; Thomson, W Murray
2011-03-01
To determine surgical and prosthodontic outcomes of mandibular single-implant overdentures, opposing complete maxillary dentures, using a wide diameter implant and large ball attachment system compared with different regular diameter implants with standard attachment systems. Thirty-six edentulous participants (mean age 68 years, SD 9.2) were randomly assigned into three treatment groups (n=12). A single implant was placed in the mandibular midline of participants to support an overdenture using a 6-week loading protocol. The control group received Southern regular implants and standard ball attachments. One group received Southern 8-mm-wide implants and large ball attachments. Another group received Neoss regular implants and Locator attachments. Parametric and non-parametric tests of a statistical software package (SPSS) were used to determine between groups differences in marginal bone loss, implant stability, implant, and prosthodontic success (P<0.05). Implant success after 1 year was 75% for Southern regular implant (control) group; and 100% for the Southern wide and Neoss regular implant groups (P=0.038). Mean marginal bone loss at 1 year was 0.19 mm (SD 0.39) without significant differences observed. Implant stability quotient (ISQ) at baseline was significantly lower for the Southern regular (control) group than the other two groups (P=0.001; P=0.009). At 1 year, no significant difference in implant stability was observed (mean ISQ 74.6, SD 6.1). The change in implant stability from baseline to 1 year was significant for the control group (P=0.025). Prosthodontic success was comparable between the groups but the maintenance (41 events overall, mean 1.2) was greater for the Locator and the standard ball attachments. Mandibular single-implant overdentures are a successful treatment option for older edentulous adults with early loading protocol using implants of different diameters and with different attachment systems. © 2010 John Wiley & Sons A/S.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ben-David, Merav, E-mail: Merav.ben-david@sheba.health.gov.il; Sackler School of Medicine, Tel Aviv University, Tel Aviv; Granot, Hila
2016-07-01
Immediate implant-based breast reconstruction followed by postmastectomy radiation therapy (PMRT) is controversial because of the risk of compromised treatment plans and concerns regarding cosmetic outcomes. We evaluated the effects of immediate direct-to-implant breast reconstruction with anatomical implants on the quality of PMRT delivered by 3-dimensional conformal radiotherapy (3D-CRT). In this retrospective, single-institution study, patients who had undergone reconstruction with direct anatomic implant, performed by a single surgeon, received 3D-CRT between 2008 and 2013. For each patient, 2 plans (including or excluding internal mammary nodes [IMN]) were created and calculated. The primary end point was the dose distribution among reconstructed breasts,more » heart, lungs, and IMNs, and between right and left breasts. Of 29 consecutive patients, 11 received right-sided and 18 received left-sided PMRT to a total dose of 50 Gy. For plans excluding IMN coverage, mean D{sub mean} for right and left reconstructed breasts was 49.09 Gy (98.2% of the prescribed dose) and 48.51 Gy (97.0%), respectively. For plans including IMNs, mean D{sub mean} was 49.15 Gy (98.3%) for right and 48.46 Gy (96.9%) for left reconstructed breasts; the mean IMN D{sub mean} was 47.27 Gy (right) and 47.89 Gy (left). Heart D{sub mean} was below 1.56 Gy for all plans. Mean total lung volume receiving a dose of ≥ 20 Gy was 13.80% to 19.47%. PMRT can be delivered effectively and safely by 3D-CRT after direct-to-implant breast reconstruction with anatomical implants, even if patients require IMN treatment.« less
Krishnan, Naveen M; Chatterjee, Abhishek; Rosenkranz, Kari M; Powell, Stephen G; Nigriny, John F; Vidal, Dale C
2014-04-01
Expander-implant breast reconstruction is often supplemented with acellular dermal matrix (ADM). The use of acellular dermal matrix has allowed for faster, less painful expansions and improved aesthetics, but with increased cost. Our goal was to provide the first cost utility analysis of using acellular dermal matrix in two-stage, expander-implant immediate breast reconstruction following mastectomy. A comprehensive literature review was conducted to identify complication rates for two-stage, expander-implant immediate breast reconstruction with and without acellular dermal matrix. The probabilities of the most common complications were combined with Medicare Current Procedural Terminology reimbursement codes and expert utility estimates to fit into a decision model. The decision model evaluated the cost effectiveness of acellular dermal matrix relative to reconstructions without it. Retail costs for ADM were derived from the LifeCell 2012 company catalogue for Alloderm. The overall complication rates were 30% and 34.5% with and without ADM. The decision model revealed a baseline cost increase of $361.96 when acellular dermal matrix is used. The increase in Quality-Adjusted Life Years (QALYs) is 1.37 in the population with acellular dermal matrix. This yields a cost effective incremental cost-utility ratio (ICUR) of $264.20/QALY. Univariate sensitivity analysis confirmed that using acellular dermal matrix is cost effective even when using retail costs for unilateral and bilateral reconstructions. Our study shows that, despite an increased cost, acellular dermal matrix is a cost effective technology for patients undergoing two-stage, expander-implant immediate breast reconstruction due to its increased utility in successful procedures. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.
Khzam, Nabil; Arora, Himanshu; Kim, Paul; Fisher, Anthony; Mattheos, Nikos; Ivanovski, Saso
2015-12-01
The aim of this review is to assess the outcome of single-tooth immediate implant placement and restoration (IPR) in the maxillary anterior region, with a particular emphasis on soft tissue and esthetic outcomes. An electronic search in Medline, EBSCOhost, and Ovid (PubMed) was performed to identify studies that reported on soft tissue outcomes following immediate placement and restoration of implants in the maxillary esthetic region with a mean follow-up of ≥1 year. Nineteen studies on single implants inserted immediately into fresh extraction sockets and provisionally restored in the maxillary esthetic region were included. Soft tissue changes were found to be acceptable, with most studies reporting mean gingival recession of 0.27 ± 0.38 mm and mean papillary height loss of 0.23 ± 0.27 mm after follow-up of ≥1 year. Advanced buccal recession (>1 mm) occurred in 11% of cases. Long-term follow-up studies (>2 years) reported that the interdental papillae, in particular, showed a tendency to rebound over time. The few studies that reported on patient-centered outcomes showed a high level of patient satisfaction with the outcomes of IPR treatment. The IPR protocol resulted in generally acceptable soft tissue and esthetic outcomes, with suboptimal results reported in ≈11% of low-risk cases. Factors such as preoperative tissue biotype or use of a flap or connective tissue graft did not significantly influence soft tissue and esthetic outcomes. Long-term prospective controlled clinical trials are necessary to identify factors that may influence the esthetic outcomes associated with IPR.
Influence of the implant abutment types and the dynamic loading on initial screw loosening
Kim, Eun-Sook
2013-01-01
PURPOSE This study examined the effects of the abutment types and dynamic loading on the stability of implant prostheses with three types of implant abutments prepared using different fabrication methods by measuring removal torque both before and after dynamic loading. MATERIALS AND METHODS Three groups of abutments were produced using different types of fabrication methods; stock abutment, gold cast abutment, and CAD/CAM custom abutment. A customized jig was fabricated to apply the load at 30° to the long axis. The implant fixtures were fixed to the jig, and connected to the abutments with a 30 Ncm tightening torque. A sine curved dynamic load was applied for 105 cycles between 25 and 250 N at 14 Hz. Removal torque before loading and after loading were evaluated. The SPSS was used for statistical analysis of the results. A Kruskal-Wallis test was performed to compare screw loosening between the abutment systems. A Wilcoxon signed-rank test was performed to compare screw loosening between before and after loading in each group (α=0.05). RESULTS Removal torque value before loading and after loading was the highest in stock abutment, which was then followed by gold cast abutment and CAD/CAM custom abutment, but there were no significant differences. CONCLUSION The abutment types did not have a significant influence on short term screw loosening. On the other hand, after 105 cycles dynamic loading, CAD/CAM custom abutment affected the initial screw loosening, but stock abutment and gold cast abutment did not. PMID:23509006
A novel root analogue dental implant using CT scan and CAD/CAM: selective laser melting technology.
Figliuzzi, M; Mangano, F; Mangano, C
2012-07-01
Direct laser metal forming (DLMF) is a new technique which allows solids with complex geometry to be produced by annealing metal powder microparticles in a focused laser beam, according to a computer-generated three-dimensional (3D) model. For dental implants, the fabrication process involves the laser-induced fusion of titanium microparticles, in order to build, layer by layer, the desired object. Modern computed tomography (CT) acquisition and 3D image conversion, combined with the DLMF process, allows the fabrication of custom-made, root-analogue implants (RAI), perfect copies of the radicular units that need replacing. This report demonstrates the successful clinical use of a custom-made, root-analogue DLMF implant. CT images of the residual non-restorable root of a right maxillary premolar were acquired and modified with specific software into a 3D model. From this model, a custom-made, root-analogue, DLMF implant was fabricated. Immediately after tooth extraction, the root-analogue implant was placed in the extraction socket and restored with a single crown. At the 1-year follow-up examination, the custom-made implant showed almost perfect functional and aesthetic integration. The possibility of fabricating custom-made, root-analogue DLMF implants opens new interesting perspectives for immediate placement of dental implants. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Maló, Paulo; de Araújo Nobre, Miguel; Lopes, Armando; Ferro, Ana; Gravito, Inês
2015-10-01
Studies are needed to evaluate long-term outcomes of the All-on-4® treatment concept (Nobel Biocare AB) for rehabilitation of edentulous mandibles by assessing marginal bone levels and risk indicators for implant failure. To evaluate 7-year clinical outcomes and 5-year radiographic outcomes of the All-on-4 treatment concept. This retrospective case series included patients admitted for implant rehabilitations in the mandible, who were followed for 7 years clinically and 5 years radiographically. Primary outcome measures were cumulative prosthetic and implant survival using patient as the unit of analysis (Kaplan-Meier product limit estimator). Secondary outcome measure was marginal bone level (MBL) at 5 years. Variables associated with implant failure were analyzed using the Cox proportional hazards regression model to calculate hazard ratios (HRs) with 95% confidence intervals (CIs). Binary logistic regression was used to compute odds ratio (OR) with 95% CIs for variables associated with MBL ≥2.8 mm at 5 years. A total of 324 patients (194 women, 130 men, average age = 58.9 years) were rehabilitated with 1,296 implants supporting 324 full-arch fixed immediately loaded mandibular prostheses. Sixty-four patients (19.8%) were lost to follow-up. Prosthetic survival was 323/324 (99.7%), and 14 patients lost 18 implants, with an estimated cumulative survival rate of 95.4% at 7 years. Variables associated with implant failure were smoking (HR = 5.28; 95% CI: 1.33, 20.91]) and the learning curve effect (0.69 < HR < 0.33 for more experienced levels). Mean MBL at 5 years was 1.81 mm (95% CI: 1.70, 1.92), and smoking was associated with MBL ≥2.8 mm (OR = 2.4; 95% CI: 1.02, 5.62). The high implant and prosthetic survival rates and excellent MBL outcome confirm the predictability and safety of the All-on-4 treatment concept over a longer term than previously reported. © 2014 Wiley Periodicals, Inc.
Falke, Lucas L; van Vuuren, Stefan H; Kazazi-Hyseni, Filis; Ramazani, Farshad; Nguyen, Tri Q; Veldhuis, Gert J; Maarseveen, Erik M; Zandstra, Jurjen; Zuidema, Johan; Duque, Luisa F; Steendam, Rob; Popa, Eliane R; Kok, Robbert Jan; Goldschmeding, Roel
2015-02-01
Kidney injury triggers fibrosis, the final common pathway of chronic kidney disease (CKD). The increase of CKD prevalence worldwide urgently calls for new therapies. Available systemic treatment such as rapamycin are associated with serious side effects. To study the potential of local antifibrotic therapy, we administered rapamycin-loaded microspheres under the kidney capsule of ureter-obstructed rats and assessed the local antifibrotic effects and systemic side effects of rapamycin. After 7 days, microsphere depots were easily identifiable under the kidney capsule. Both systemic and local rapamycin treatment reduced intrarenal mTOR activity, myofibroblast accumulation, expression of fibrotic genes, and T-lymphocyte infiltration. Upon local treatment, inhibition of mTOR activity and reduction of myofibroblast accumulation were limited to the immediate vicinity of the subcapsular pocket, while reduction of T-cell infiltration was widespread. In contrast to systemically administered rapamycin, local treatment did not induce off target effects such as weight loss. Thus subcapsular delivery of rapamycin-loaded microspheres successfully inhibited local fibrotic response in UUO with less systemic effects. Therapeutic effect of released rapamycin was most prominent in close vicinity to the implanted microspheres. Copyright © 2014 Elsevier Ltd. All rights reserved.
Immediate outcomes of eptifibatide therapy during intracoronary stent implantation.
Shariati, Hooman; Sanei, Hamid; Pourmoghadas, Ali; Salehizadeh, Leila; Amirpour, Afshin
2016-01-01
The objective of the present study was to assess the major immediate outcomes of eptifibatide therapy during intracoronary stent implantation. In an interventional study, patients undergoing percutaneous coronary intervention (PCI) were randomized into either the eptifibatide ( n = 100) or the control ( n = 107) group. In each group, demographic and clinical characteristics such as cardiac death, stent thrombosis (ST), myocardial infarction (MI), rates of target lesion and vessel revascularization, cerebral vascular accident (CVA), and emergency coronary artery bypass grafting (CABG) were recorded. The overall rates of major adverse events such as mortality, Stent thrombosis (ST), Myocardial Infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), CVA, and emergency CABG within 24 h after stent implantation were low and comparable between the two groups; P > 0.05 considered significant for all comparisons. There were no statistical differences between the clinical outcomes of groups administered with single-dose intracoronary eptifibatide and control groups among patients undergoing PCI during stent implantation.
Shen, Wan-Ling; Chen, Chen-Sheng; Hsu, Ming-Lun
2010-01-01
To evaluate the influence of implant collar geometry on the distribution of stress and strain in the crestal compact bone contiguous to an implant collar for four types of bone under axial and oblique loads. Finite element models of threaded implants with three kinds of implant collar designs (divergent, straight, and convergent) with their corresponding suprastructures embedded in the posterior mandible were created with ANSYS software. Eight different test conditions incorporating four types of bone (orthotropic and effectively isotropic in part 1 and high and low densities in part 2) under separate 100-N axial and 35.6-degree oblique forces were created to investigate the stress and strain distributions in the crestal compact bone around the implant collars. In all eight conditions, the divergent collar demonstrated the lowest maximum von Mises and principal stresses and strains in the crestal compact bone contiguous to the implant collar, followed by the straight and convergent collars. The oblique load induced higher peak values than the axial load. The orthotropic design amplified and increased the pathologic microstrains and tensile stresses in the crestal compact bone compared to the effectively isotropic design, especially in models with a convergent collar design. In part 2 of the study, the maximum von Mises stresses and strains increased with a decrease in the cancellous bone density. Under oblique loading, the convergent and straight collars showed pathologic microstrain values as well as excessive ultimate tensile stresses in the orthotropic bone model with low-density cancellous bone. Within the limitations, it was concluded that stress and strain distributions in the adjacent compact bone are influenced by the implant collar design. The divergent implant collar design was associated with the lowest stress and strain concentrations in the crestal compact bone.
de Ruiter, Lennert; Janssen, Dennis; Briscoe, Adam; Verdonschot, Nico
2017-12-01
The current study was designed to investigate the mechanical response of a polyetheretherketone-on-polyethylene total knee replacement device during a deep squat. Application of this high-demand loading condition can identify weaknesses of the polyetheretherketone relative to cobalt-chromium. This study investigated whether the implant is strong enough for this type of loading, whether cement stresses are considerably changed and whether a polyetheretherketone femoral component is likely to lead to reduced periprosthetic bone loss as compared to a cobalt-chromium component. A finite element model of a total knee arthroplasty subjected to a deep squat loading condition, which was previously published, was adapted with an alternative total knee arthroplasty design made of either polyetheretherketone or cobalt-chromium. The maximum tensile and compressive stresses within the implant and cement mantle were analysed against their yield and fatigue stress levels. The amount of stress shielding within the bone was compared between the polyetheretherketone and cobalt-chromium cases. Relative to its material strength, tensile peak stresses were higher in the cobalt-chromium implant; compressive peak stresses were higher in the polyetheretherketone implant. The stress patterns differed substantially between polyetheretherketone and cobalt-chromium. The tensile stresses in the cement mantle supporting the polyetheretherketone implant were up to 33% lower than with the cobalt-chromium component, but twice as high for compression. Stress shielding was reduced to a median of 1% for the polyetheretherketone implant versus 56% for the cobalt-chromium implant. Both the polyetheretherketone implant and the underlying cement mantle should be able to cope with the stress levels present during a deep squat. Relative to the cobalt-chromium component, stress shielding of the periprosthetic femur was substantially less with a polyetheretherketone femoral component.
Jaw In A Day™ – State of the Art in Maxillary Reconstruction
Runyan, Christopher M.; Sharma, Vishal; Staffenberg, David A.; Levine, Jamie P.; Brecht, Lawrence E.; Wexler, Leonard H.; Hirsch, David L.
2017-01-01
Background Reconstruction of maxillary defects following tumor extirpation is challenging because of combined aesthetic and functional roles of the maxilla. One-stage reconstruction combining osseous free flaps with immediate osseointegrated implants are becoming the standard for mandibular defects, and have similar potential for maxillary reconstruction. Methods A woman with maxillary Ewing’s sarcoma successfully treated at age nine with neoadjuvant chemotherapy, right hemi-maxillectomy and obturator prosthetic reconstruction presented for definitive reconstruction, complaining of poor obturator fit and hypernasality. Her reconstruction was computer-simulated by a multi-disciplinary team, consisting of left hemi-Lefort I advancement and right maxillary reconstruction with a free fibula flap with immediate osseointegrated implants and dental prosthesis. Results Full dental restoration, midface projection and oral fistula corrections were achieved in one operative stage using this approach. Conclusions This case demonstrates a successful approach for maxillary reconstruction using computer-planned orthognathic surgery with free fibula reconstruction and immediate osseointegrated implants with dental prosthesis. PMID:28005762
Molina, Ana; Sanz-Sánchez, Ignacio; Martín, Conchita; Blanco, Juan; Sanz, Mariano
2017-04-01
To compare the effect of placing the definitive abutment at the time of implant placement versus at a later stage, on the soft and hard tissue changes around dental implants. Platform-switched implants were placed in the posterior maxilla or mandible of partial edentulous patients and they were randomized to receive the definitive abutment at the moment of implant placement, or 6-12 weeks later. Final prostheses were delivered 2-4 weeks later. Radiographic assessment of vertical bone level changes (primary outcome), clinical status of peri-implant tissues, changes in soft tissues margin, papilla filling, patient-related outcomes and adverse events were assessed 6 and 12 months after loading. 60 implants were placed in 40 patients, replacing single or multiple absent teeth. One implant was lost 1 week after insertion (overall survival rate: 98.3%). A statistically significant greater bone resorption from surgery to 6 months post-loading was observed for those implants subjected to abutment change (control group: -1.24 ± 0.79 mm; test group: -0.61 ± 0.40 mm; P = 0.028). Periodontal clinical parameters and patient-related outcomes, however, did not demonstrate significant differences between groups at any time point. A significant increase in papilla height was observed from loading to 12 months in all implants (control group: 1.17 ± 1.47 mm; test group: 0.98 ± 0.89 mm) and a slight but not significant coronal migration of the gingival margin. The connection and disconnection of healing abutments is associated with significantly increased bone loss during the healing period between implant placement and 6 months post-loading, when compared to one-time abutment placement. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
The effect of in situ augmentation on implant anchorage in proximal humeral head fractures.
Unger, Stefan; Erhart, Stefanie; Kralinger, Franz; Blauth, Michael; Schmoelz, Werner
2012-10-01
Fracture fixation in patients suffering from osteoporosis is difficult as sufficient implant anchorage is not always possible. One method to enhance implant anchorage is implant/screw augmentation with PMMA-cement. The present study investigated the feasibility of implant augmentation with PMMA-cement to enhance implant anchorage in the proximal humerus. A simulated three part humeral head fracture was stabilised with an angular stable plating system in 12 pairs of humeri using six head screws. In the augmentation group the proximal four screws were treated with four cannulated screws, each augmented with 0.5ml of PMMA-cement, whereas the contra lateral side served as a non-augmented control. Specimens were loaded in varus-bending or axial-rotation using a cyclic loading protocol with increasing load magnitude until failure of the osteosynthesis occurred. Augmented specimens showed a significant higher number of load cycles until failure than non-augment specimens (varus-bending: 8516 (SD 951.6) vs. 5583 (SD 2273.6), P=0.014; axial-rotation: 3316 (SD 348.8) vs. 2050 (SD 656.5), P=0.003). Non-augmented specimens showed a positive correlation of load cycles until failure and measured bone mineral density (varus-bending: r=0.893, P=0.016; axial-rotation: r=0.753, P=0.084), whereas no correlation was present in augmented specimens (varus-bending: r=0,258, P=0.621; axial-rotation r=0.127, P=0.810). These findings suggest that augmentation of cannulated screws is a feasible method to enhance implant/screw anchorage in the humeral head. The improvement of screw purchase is increasing with decreasing bone mineral density. Copyright © 2012 Elsevier Ltd. All rights reserved.
Lemos, Cleidiel Aparecido Araujo; Verri, Fellippo Ramos; Santiago, Joel Ferreira; Almeida, Daniel Augusto de Faria; Batista, Victor Eduardo de Souza; Noritomi, Pedro Yoshito; Pellizzer, Duardo Piza
2018-01-01
The purpose of this study was to evaluate different retention systems (cement- or screw-retained) and crown designs (non-splinted or splinted) of fixed implant-supported restorations, in terms of stress distributions in implants/components and bone tissue, by 3-dimensional (3D) finite element analysis. Four 3D models were simulated with the InVesalius, Rhinoceros 3D, and SolidWorks programs. Models were made of type III bone from the posterior maxillary area. Models included three 4.0-mm-diameter Morse taper (MT) implants with different lengths, which supported metal-ceramic crowns. Models were processed by the Femap and NeiNastran programs, using an axial force of 400 N and oblique force of 200 N. Results were visualized as the von Mises stress and maximum principal stress (σmax). Under axial loading, there was no difference in the distribution of stress in implants/components between retention systems and splinted crowns; however, in oblique loading, cemented prostheses showed better stress distribution than screwed prostheses, whereas splinted crowns tended to reduce stress in the implant of the first molar. In the bone tissue cemented prostheses showed better stress distribution in bone tissue than screwed prostheses under axial and oblique loading. The splinted design only had an effect in the screwed prosthesis, with no influence in the cemented prosthesis. Cemented prostheses on MT implants showed more favorable stress distributions in implants/components and bone tissue. Splinting was favorable for stress distribution only for screwed prostheses under oblique loading.
Costantini, Oren; Choi, Daniel S; Kontaxis, Andreas; Gulotta, Lawrence V
2015-07-01
There has been a renewed interest in lateralizing the center of rotation (CoR) in implants used in reverse shoulder arthroplasty. The aim of this study was to determine the sensitivity of lateralization of the CoR on the glenohumeral joint contact forces, muscle moment arms, torque across the bone-implant interface, and the stability of the implant. A 3-dimensional virtual model was used to investigate how lateralization affects deltoid muscle moment arm and glenohumeral joint contact forces. This model was virtually implanted with 5 progressively lateralized reverse shoulder prostheses. The joint contact loads and deltoid moment arms were calculated for each lateralization over the course of 3 simulated standard humerothoracic motions. Lateralization of the CoR leads to an increase in the overall joint contact forces across the glenosphere. Most of this increased loading occurred through compression, although increases in anterior/posterior and superior/inferior shear were also observed. Moment arms of the deltoid consistently decreased with lateralization. Bending moments at the implant interface increased with lateralization. Progressive lateralization resulted in improved stability ratios. Lateralization results in increased joint loading. Most of that loading occurs through compression, although there were also increases in shear forces. Anterior/posterior shear is currently not accounted for in implant fixation studies, leaving its effect on implant fixation unknown. Future studies should incorporate shear forces into their models to more accurately assess fixation methods. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Protopapadaki, Maria; Monaco, Edward A; Kim, Hyeong-Il; Davis, Elaine L
2013-11-01
The predictable nature of the hot pressing ceramic technique has several applications, but no study was identified that evaluated its application to the fabrication of custom implant abutments. The purpose of this study was to compare the fracture resistance of an experimentally designed pressable metal ceramic custom implant abutment (PR) with that of a duplicate zirconia abutment (ZR). Two groups of narrow platform (NP) (Nobel Replace) implant abutment specimens were fabricated (n=10). The experimental abutment (PR) had a metal substructure cast with ceramic alloy (Lodestar) and veneered with leucite pressable glass ceramic (InLine PoM). Each PR abutment was individually scanned and 10 duplicate CAD/CAM ZR abutments were fabricated for the control group. Ceramic crowns (n=20) with the average dimensions of a human lateral incisor were pressed with lithium disilicate glass ceramic (IPS e.max Press) and bonded on the abutments with a resin luting agent (Multilink Automix). The specimens were subjected to thermocycling, cyclic loading, and finally static loading to failure with a computer-controlled Universal Testing Machine. An independent t test (1 sided) determined whether the mean values of the fracture load differed significantly (α=.05) between the 2 groups. No specimen failed during cyclic loading. Upon static loading, the mean (SD) load to failure was significantly higher for the PR group (525.89 [143.547] N) than for the ZR group (413.70 [35.515] N) for internal connection narrow platform bone-level implants (P=.025). Failure was initiated at the screw and internal connection level for both groups. It is possible to fabricate PR abutments that are stronger than ZR abutments for Nobel Biocare internal connection NP bone-level implants. The screw and the internal connection are the weak links for both groups. Copyright © 2013 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Fracture analysis of randomized implant-supported fixed dental prostheses
Esquivel-Upshaw, Josephine F.; Mehler, Alex; Clark, Arthur E.; Neal, Dan; Anusavice, Kenneth J.
2014-01-01
Objective Fractures of posterior fixed dental all-ceramic prostheses can be caused by one or more factors including prosthesis design, flaw distribution, direction and magnitude of occlusal loading, and nature of supporting infrastructure (tooth root/implant), and presence of adjacent teeth. This clinical study of implant-supported, all-ceramic fixed dental prostheses, determined the effects of (1) presence of a tooth distal to the most distal retainer; (2) prosthesis loading either along the non-load bearing or load bearing areas; (3) presence of excursive contacts or maximum intercuspation contacts in the prosthesis; and (4) magnitude of bite force on the occurrence of veneer ceramic fracture. Methods 89 implant-supported FDPs were randomized as either a three-unit posterior metal-ceramic (Au-Pd-Ag alloy and InLine POM, Ivoclar, Vivadent) FDP or a ceramic-ceramic (ZirCAD and ZirPress, Ivoclar, Vivadent) FDP. Two implants (Osseospeed, Dentsply) and custom abutments (Atlantis, Dentsply) supported these FDPs, which were cemented with resin cement (RelyX Universal Cement). Baseline photographs were made with markings of teeth from maximum intercuspation (MI) and excursive function. Patients were recalled at 6 months and 1 to 3 years. Fractures were observed, their locations recorded, and images compared with baseline photographs of occlusal contacts. Conclusion No significant relationship exists between the occurrence of fracture and: (1) the magnitude of bite force; (2) a tooth distal to the most distal retainer; and (3) contacts in load-bearing or non-load-bearing areas. However, there was a significantly higher likelihood of fracture in areas with MI contacts only. Clinical Significance This clinical study demonstrates that there is a need to evaluate occlusion differently with implant-supported prostheses than with natural tooth supported prostheses because of the absence of a periodontal ligament. Implant supported prostheses should have minimal occlusion and lighter contacts than ones supported by natural dentition. PMID:25016139
Resonance Frequency Analysis for Osseointegration in Four Surgical Conditions of Dental Implants
2001-10-25
Osseointegration has been defined as “a process whereby a clinically asymptomatic rigid fixation of alloplastic materials is achieved and maintained...as the immediate implantation technique. In IIT model, the cervical third of dental implants are contacted to bone grafting materials, and apical ...Council, NSC- 89-2213-E-038-007. REFERENCES [1] Albrektsson T, Sennerby L. State of the art in oral implant. J. Clin. Periodontal . vol.18, pp. 474
Berahmani, Sanaz; Hendriks, Maartje; Wolfson, David; Wright, Abraham; Janssen, Dennis; Verdonschot, Nico
2017-11-01
To achieve long-lasting fixation of cementless implants, an adequate primary stability is required. We aimed to compare primary stability of a new cementless femoral knee component (Attune®) against a conventional implant (LCS®) under different loading conditions. Six pairs of femora were prepared following the normal surgical procedure. Calibrated CT-scans and 3D-optical scans of the bones were obtained to measure bone mineral density (BMD) and cut accuracy, respectively. Micromotions were measured in nine regions of interest at the bone-implant interface using digital image correlation. The reconstructions were subjected to the implant-specific's peak tibiofemoral load of gait and a deep knee bend loading profiles. Afterwards, the implants were pushed-off at a flexion angle of 150°. Micromotions of Attune were significantly lower than LCS under both loading conditions (P ≤ 0.001). Cut accuracy did not affect micromotions, and BMD was only a significant factor affecting the micromotions under simplified gait loading. No significant difference was found in high-flex push-off force, but Attune required a significantly higher load to generate excessive micromotions during push-off. Parallel anterior and posterior bone cuts in the LCS versus the tapered bone cuts of the Attune may explain the difference between the two designs. Additionally, the rims at the borders of the LCS likely reduced the area of contact with the bone for the LCS, which may have affected the initial fixation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Makowiecki, Arkadiusz; Botzenhart, Ute; Seeliger, Julia; Heinemann, Friedhelm; Biocev, Peter; Dominiak, Marzena
2017-07-01
The objective of the present study was to compare the primary and secondary stability of tissue-level short dental titanium implants with polished necks and hydrophilic surfaces of two different designs and manufacturers. The first implant system used (SPI ® ELEMENT RC INICELL titanium implants, Thommen Medical AG, Grenchen, Switzerland), allowed functional loading 6 weeks after its placement, whereas the second implant system (RN SLActiv ® tissue-level titanium implants, Straumann GmbH, Fribourg, Germany), was loaded after 15 weeks. The degree of primary and secondary stability was determined using an Osstell ISQ measuring device. Marginal bone loss (MBL) was evaluated radiographically 12 and 24 weeks after implantation and the Wachtel's healing index as well as the patient's satisfaction with the treatment was registered on a VAS scale. The intergroup comparison revealed significant differences in terms of primary stability as well as differences in MBL 3 months after the procedure, but no significant differences could be found after 6 months and for secondary stability. The primary stability was significantly higher for Thommen ® compared to Straumann ® implants. Insertion of short dental implants with a hydrophilic conditioned surface significantly shortens patient treatment time. Copyright © 2017 Elsevier GmbH. All rights reserved.
Matys, Jacek; Flieger, Rafał; Tenore, Gianluca; Grzech-Leśniak, Kinga; Romeo, Umberto; Dominiak, Marzena
2018-04-01
It is important to identify factors that affect primary stability of orthodontic mini-implants because it determines the success of treatment. We assessed mini-implant primary stability (initial mechanical engagement with the bone) placed in pig jaws. We also assessed mini-implant insertion failure rate (mini-implant fracture, mini-implants to root contact). A total of 80 taper-shaped mini-implants (Absoanchor® Model SH1312-6; Dentos Inc., Daegu, Korea) 6 mm long with a diameter of 1.1 mm were used. Bone decortication was made before mini-implant insertion by means of three different methods: Group G1: Er:YAG laser (LiteTouch®, Light Instruments, Yokneam, Israel) at energy of 300 mJ, frequency 25 Hz, fluence 38.2 J/cm2, cooling 14 ml/min, tip 1.0 × 17 mm, distance 1 mm, time of irradiation 6 s; Group G2: drill (Hager & Meisinger GmbH, Hansemannstr, Germany); Group G3: piezosurgery (Piezotom Solo, Acteon, NJ, USA). In G4 group (control), mini-implants were driven by a self-drilling method. The primary stability of mini-implants was assessed by measuring damping characteristics between the implant and the tapping head of Periotest device (Gulden-Medizinteknik, Eschenweg, Modautal, Germany). The results in range between - 8 to + 9 allowed immediate loading. Significantly lower Periotest value was found in the control group (mean 0.59 ± 1.57, 95% CI 0.7, 2.4) as compared with Er:YAG laser (mean 4.44 ± 1.64, 95% CI 3.6, 5.3), piezosurgery (mean 17.92 ± 2.73, 95% CI 16.5, 19.3), and a drill (mean 5.91 ± 1.52, 95% CI 5.2, 6.6) (p < 0.05). The highest failure rate (33.3%) during mini-implant insertion was noted for self-drilling method (G4) as compared with G1, G2, and G3 groups (p < 0.05). The small diameter decortication by Er:YAG laser appeared to provide better primary stability as compared to drill and piezosurgery. Decortication of the cortical bone before mini-implant insertion resulted in reduced risk of implant fracture or injury of adjacent teeth. The high initial stability with a smaller diameter of the mini-implant resulted in increased risk of fracture, especially for a self-drilling method.
Pérez, M A
2012-12-01
Probabilistic analyses allow the effect of uncertainty in system parameters to be determined. In the literature, many researchers have investigated static loading effects on dental implants. However, the intrinsic variability and uncertainty of most of the main problem parameters are not accounted for. The objective of this research was to apply a probabilistic computational approach to predict the fatigue life of three different commercial dental implants considering the variability and uncertainty in their fatigue material properties and loading conditions. For one of the commercial dental implants, the influence of its diameter in the fatigue life performance was also studied. This stochastic technique was based on the combination of a probabilistic finite element method (PFEM) and a cumulative damage approach known as B-model. After 6 million of loading cycles, local failure probabilities of 0.3, 0.4 and 0.91 were predicted for the Lifecore, Avinent and GMI implants, respectively (diameter of 3.75mm). The influence of the diameter for the GMI implant was studied and the results predicted a local failure probability of 0.91 and 0.1 for the 3.75mm and 5mm, respectively. In all cases the highest failure probability was located at the upper screw-threads. Therefore, the probabilistic methodology proposed herein may be a useful tool for performing a qualitative comparison between different commercial dental implants. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Suhm, Norbert; Hengg, Clemens; Schwyn, Ronald; Windolf, Markus; Quarz, Volker; Hänni, Markus
2007-08-01
Bone strength plays an important role in implant anchorage. Bone mineral density (BMD) is used as surrogate parameter to quantify bone strength and to predict implant anchorage. BMD can be measured by means of quantitative computer tomography (QCT) or dual energy X-ray absorptiometry (DXA). These noninvasive methods for BMD measurement are not available pre- or intra-operatively. Instead, the surgeon could determine bone strength by direct mechanical measurement. We have evaluated mechanical torque measurement for (A) its capability to quantify local bone strength and (B) its predictive value towards load at implant cut-out. Our experimental study was performed using sixteen paired human cadaver proximal femurs. BMD was determined for all specimens by QCT. The torque to breakaway of the cancellous bone structure (peak torque) was measured by means of a mechanical probe at the exact position of subsequent DHS placement. The fixation strength of the DHS achieved was assessed by cyclic loading in a stepwise protocol beginning with 1,500 N increasing 500 N every 5,000 cycles until 4,000 N. A highly significant correlation of peak torque with BMD (QCT) was found (r = 0.902, r (2) = 0.814, P < 0.001). Peak torque correlated highly significant with the load at implant cut-out (r = 0.795, P < 0.001). All specimens with a measured peak torque below 6.79 Nm failed at the first load level of 1,500 N. The specimens with a peak torque above 8.63 Nm survived until the last load level of 4,000 N. Mechanical peak torque measurement is able to quantify bone strength. In an experimental setup, peak torque identifies those specimens that are likely to fail at low load. In clinical routine, implant migration and cut-out depend on several parameters, which are difficult to control, such as fracture type, fracture reduction achieved, and implant position. The predictive value of peak torque towards cut-out in a clinical set-up therefore has to be carefully validated.
Peñarrocha, Miguel; Carrillo, Celia; Boronat, Araceli; Peñarrocha, Maria
2009-01-01
The aim of this study was to evaluate the success rate of implants placed in the pterygomaxillary region using drills and osteotomes with a minimum of 12 months' follow-up. Bone loss after 1 year of loading and patient satisfaction with the prosthesis were evaluated. A retrospective case study was made. The sample was composed of patients rehabilitated with pterygoid implants between January 2000 and January 2006. The inclusion criteria were patients in good general health with severe atrophy of the posterior maxilla who had been rehabilitated with one or two pterygoid implants inserted using drills and osteotomes and had been followed for 12 months after implant loading. Implant success was defined according to the criteria of Albrektsson et al. Bone loss was measured on panoramic radiographs on the mesial and distal of each implant, and the largest value (whether mesial or distal) was selected as the bone loss for the implant in question. Subjects indicated satisfaction with the new prosthesis on a visual analogue scale. Forty-five patients were treated with 268 implants (200 anterior and 68 pterygoid). The success rate of pterygoid implants was 97.05%. The mean bone loss around implants in the pterygomaxillary region after 1 year of loading was 0.71 mm (range, 0 to 3.20). All prostheses were stable at the end of the observation period. Patients were satisfied with comfort and stability, ability to speak, ease of cleaning, and esthetics and functionality of the prosthesis. Placement of implants in the posterior pterygomaxillary region using drills and osteotomes is a viable alternative treatment modality for rehabilitation of atrophic posterior maxilla. Patients were satisfied with a prosthesis supported by pterygoid implants.
Li, Dan; Li, Litao; Ma, Yunlong; Zhuang, Yaping; Li, Dawei; Shen, Hong; Wang, Xing; Yang, Fei; Ma, Yuanzheng; Wu, Decheng
2017-03-28
Currently, the major issues in the treatment of osteoarticular tuberculosis (TB) after implant placement are low drug concentration at the infected focus and drug resistance resulting from the long-term chemotherapy. The application of drug-loaded polymeric multilayers on implantable devices offers a promising solution to the problems. Herein, a poly(ethylene glycol)-based hydrogel film embedded with isoniazid (INH)-loaded alginate microparticles was fixed to Ti implants via adhesive polydopamine, subsequently capped by poly(lactic-co-glycolic acid) membranes for the sustained and localized delivery of the anti-TB drug. The antibacterial efficacy of the released INH was confirmed by a 4.5 ± 0.8 cm inhibition zone formed in the fourth week after inoculation of Mycobacterium tuberculosis. The INH-loaded Ti implants showed no toxicity to the osteoblast cell and provided a consistent drug release for nearly one week in vitro. The release profile in vivo showed a high local concentration and low systemic exposure. The local INH concentration could be kept higher than its minimum inhibitory concentration over a period of 8 weeks, which proves that it is a promising strategy to improve the severe osteoarticular TB treatment.
Perelli, Michele; Abundo, Roberto; Corrente, Giuseppe; Saccone, Carlo
2017-01-01
Tooth extraction is usually followed by bone reduction. In the maxillary posterior region, this remodelling combined with sinus pneumatisation and periodontal defects may lead to a reduced basal bone height available for implant placement. Sinus floor elevation can be performed with different surgical techniques. Crestal approach has demonstrated to be effective, less invasive, and associated with a reduced morbidity. This article reports a modified sinus floor elevation by means of rotary, noncutting instruments, addition of xenograft, and 2 short-threaded implant placements. The aim of the study was to evaluate the implant's success and intrasinus radiographical bone gain after 4 years of functional loading. The premolar implant site presented a starting basal bone height of 6 mm, while the molar site was of 2 mm. In the first surgical step, sinus floor elevation was performed mesially and the implant was inserted, and distally only sinus floor elevation was performed. After 6 months, the mesial implant was uncovered and the second implant was inserted; 4 months later, the second fixture was uncovered, and both fixtures were loaded with single provisional screw-retained crowns and later with single screw-retained porcelain fused to metal crowns. Implants integrated successfully, and crestal bone remodelling did not exceed the smooth collar. Bone gain was 3 mm for the mesial implant and more than 5 mm for the distal one. PMID:29403665
Perelli, Michele; Abundo, Roberto; Corrente, Giuseppe; Saccone, Carlo; Arduino, Paolo G
2017-01-01
Tooth extraction is usually followed by bone reduction. In the maxillary posterior region, this remodelling combined with sinus pneumatisation and periodontal defects may lead to a reduced basal bone height available for implant placement. Sinus floor elevation can be performed with different surgical techniques. Crestal approach has demonstrated to be effective, less invasive, and associated with a reduced morbidity. This article reports a modified sinus floor elevation by means of rotary, noncutting instruments, addition of xenograft, and 2 short-threaded implant placements. The aim of the study was to evaluate the implant's success and intrasinus radiographical bone gain after 4 years of functional loading. The premolar implant site presented a starting basal bone height of 6 mm, while the molar site was of 2 mm. In the first surgical step, sinus floor elevation was performed mesially and the implant was inserted, and distally only sinus floor elevation was performed. After 6 months, the mesial implant was uncovered and the second implant was inserted; 4 months later, the second fixture was uncovered, and both fixtures were loaded with single provisional screw-retained crowns and later with single screw-retained porcelain fused to metal crowns. Implants integrated successfully, and crestal bone remodelling did not exceed the smooth collar. Bone gain was 3 mm for the mesial implant and more than 5 mm for the distal one.
Comparative analysis of stress in a new proposal of dental implants.
Valente, Mariana Lima da Costa; de Castro, Denise Tornavoi; Macedo, Ana Paula; Shimano, Antonio Carlos; Dos Reis, Andréa Cândido
2017-08-01
The purpose of this study was to compare, through photoelastic analysis, the stress distribution around conventional and modified external hexagon (EH) and morse taper (MT) dental implant connections. Four photoelastic models were prepared (n=1): Model 1 - conventional EH cylindrical implant (Ø 4.0mm×11mm - Neodent®), Model 2 - modified EH cylindrical implant, Model 3 - conventional MT Conical implant (Ø 4.3mm×10mm - Neodent®) and Model 4 - modified MT conical implant. 100 and 150N axial and oblique loads (30° tilt) were applied in the devices coupled to the implants. A plane transmission polariscope was used in the analysis of fringes and each position of interest was recorded by a digital camera. The Tardy method was used to quantify the fringe order (n), that calculates the maximum shear stress (τ) value in each selected point. The results showed lower stress concentration in the modified cylindrical implant (EH) compared to the conventional model, with application of 150N axial and 100N oblique loads. Lower stress was observed for the modified conical (MT) implant with the application of 100 and 150N oblique loads, which was not observed for the conventional implant model. The comparative analysis of the models showed that the new design proposal generates good stress distribution, especially in the cervical third, suggesting the preservation of bone tissue in the bone crest region. Copyright © 2017 Elsevier B.V. All rights reserved.
Halliday, Amy J; Campbell, Toni E; Nelson, Timothy S; McLean, Karen J; Wallace, Gordon G; Cook, Mark J
2013-01-01
Approximately one-third of people with epilepsy receive insufficient benefit from currently available anticonvulsant medication, and some evidence suggests that this may be due to a lack of effective penetration into brain parenchyma. The current study investigated the ability of biodegradable polymer implants loaded with levetiracetam to ameliorate seizures following implantation above the motor cortex in the tetanus toxin model of temporal lobe epilepsy in rats. The implants led to significantly shorter seizures and a trend towards fewer seizures for up to 1 week. The results of this study indicate that drug-eluting polymer implants represent a promising evolving treatment option for intractable epilepsy. Future research is warranted to investigate issues of device longevity and implantation site. Copyright © 2012 Elsevier Ltd. All rights reserved.