NASA Astrophysics Data System (ADS)
Oz, Alon; Hershkovitz, Shany; Tsur, Yoed
2014-11-01
In this contribution we present a novel approach to analyze impedance spectroscopy measurements of supercapacitors. Transforming the impedance data into frequency-dependent capacitance allows us to use Impedance Spectroscopy Genetic Programming (ISGP) in order to find the distribution function of relaxation times (DFRT) of the processes taking place in the tested device. Synthetic data was generated in order to demonstrate this technique and a model for supercapacitor ageing process has been obtained.
A mixed-mode traffic assignment model with new time-flow impedance function
NASA Astrophysics Data System (ADS)
Lin, Gui-Hua; Hu, Yu; Zou, Yuan-Yang
2018-01-01
Recently, with the wide adoption of electric vehicles, transportation network has shown different characteristics and been further developed. In this paper, we present a new time-flow impedance function, which may be more realistic than the existing time-flow impedance functions. Based on this new impedance function, we present an optimization model for a mixed-mode traffic network in which battery electric vehicles (BEVs) and gasoline vehicles (GVs) are chosen. We suggest two approaches to handle the model: One is to use the interior point (IP) algorithm and the other is to employ the sequential quadratic programming (SQP) algorithm. Three numerical examples are presented to illustrate the efficiency of these approaches. In particular, our numerical results show that more travelers prefer to choosing BEVs when the distance limit of BEVs is long enough and the unit operating cost of GVs is higher than that of BEVs, and the SQP algorithm is faster than the IP algorithm.
Lin, Tzu-Hsuan; Lu, Yung-Chi; Hung, Shih-Lin
2014-01-01
This study developed an integrated global-local approach for locating damage on building structures. A damage detection approach with a novel embedded frequency response function damage index (NEFDI) was proposed and embedded in the Imote2.NET-based wireless structural health monitoring (SHM) system to locate global damage. Local damage is then identified using an electromechanical impedance- (EMI-) based damage detection method. The electromechanical impedance was measured using a single-chip impedance measurement device which has the advantages of small size, low cost, and portability. The feasibility of the proposed damage detection scheme was studied with reference to a numerical example of a six-storey shear plane frame structure and a small-scale experimental steel frame. Numerical and experimental analysis using the integrated global-local SHM approach reveals that, after NEFDI indicates the approximate location of a damaged area, the EMI-based damage detection approach can then identify the detailed damage location in the structure of the building.
Development on electromagnetic impedance function modeling and its estimation
NASA Astrophysics Data System (ADS)
Sutarno, D.
2015-09-01
Today the Electromagnetic methods such as magnetotellurics (MT) and controlled sources audio MT (CSAMT) is used in a broad variety of applications. Its usefulness in poor seismic areas and its negligible environmental impact are integral parts of effective exploration at minimum cost. As exploration was forced into more difficult areas, the importance of MT and CSAMT, in conjunction with other techniques, has tended to grow continuously. However, there are obviously important and difficult problems remaining to be solved concerning our ability to collect process and interpret MT as well as CSAMT in complex 3D structural environments. This talk aim at reviewing and discussing the recent development on MT as well as CSAMT impedance functions modeling, and also some improvements on estimation procedures for the corresponding impedance functions. In MT impedance modeling, research efforts focus on developing numerical method for computing the impedance functions of three dimensionally (3-D) earth resistivity models. On that reason, 3-D finite elements numerical modeling for the impedances is developed based on edge element method. Whereas, in the CSAMT case, the efforts were focused to accomplish the non-plane wave problem in the corresponding impedance functions. Concerning estimation of MT and CSAMT impedance functions, researches were focused on improving quality of the estimates. On that objective, non-linear regression approach based on the robust M-estimators and the Hilbert transform operating on the causal transfer functions, were used to dealing with outliers (abnormal data) which are frequently superimposed on a normal ambient MT as well as CSAMT noise fields. As validated, the proposed MT impedance modeling method gives acceptable results for standard three dimensional resistivity models. Whilst, the full solution based modeling that accommodate the non-plane wave effect for CSAMT impedances is applied for all measurement zones, including near-, transition-as well as the far-field zones, and consequently the plane wave correction is no longer needed for the impedances. In the resulting robust impedance estimates, outlier contamination is removed and the self consistency between the real and imaginary parts of the impedance estimates is guaranteed. Using synthetic and real MT data, it is shown that the proposed robust estimation methods always yield impedance estimates which are better than the conventional least square (LS) estimation, even under condition of severe noise contamination. A recent development on the constrained robust CSAMT impedance estimation is also discussed. By using synthetic CSAMT data it is demonstrated that the proposed methods can produce usable CSAMT transfer functions for all measurement zones.
Development on electromagnetic impedance function modeling and its estimation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sutarno, D., E-mail: Sutarno@fi.itb.ac.id
2015-09-30
Today the Electromagnetic methods such as magnetotellurics (MT) and controlled sources audio MT (CSAMT) is used in a broad variety of applications. Its usefulness in poor seismic areas and its negligible environmental impact are integral parts of effective exploration at minimum cost. As exploration was forced into more difficult areas, the importance of MT and CSAMT, in conjunction with other techniques, has tended to grow continuously. However, there are obviously important and difficult problems remaining to be solved concerning our ability to collect process and interpret MT as well as CSAMT in complex 3D structural environments. This talk aim atmore » reviewing and discussing the recent development on MT as well as CSAMT impedance functions modeling, and also some improvements on estimation procedures for the corresponding impedance functions. In MT impedance modeling, research efforts focus on developing numerical method for computing the impedance functions of three dimensionally (3-D) earth resistivity models. On that reason, 3-D finite elements numerical modeling for the impedances is developed based on edge element method. Whereas, in the CSAMT case, the efforts were focused to accomplish the non-plane wave problem in the corresponding impedance functions. Concerning estimation of MT and CSAMT impedance functions, researches were focused on improving quality of the estimates. On that objective, non-linear regression approach based on the robust M-estimators and the Hilbert transform operating on the causal transfer functions, were used to dealing with outliers (abnormal data) which are frequently superimposed on a normal ambient MT as well as CSAMT noise fields. As validated, the proposed MT impedance modeling method gives acceptable results for standard three dimensional resistivity models. Whilst, the full solution based modeling that accommodate the non-plane wave effect for CSAMT impedances is applied for all measurement zones, including near-, transition-as well as the far-field zones, and consequently the plane wave correction is no longer needed for the impedances. In the resulting robust impedance estimates, outlier contamination is removed and the self consistency between the real and imaginary parts of the impedance estimates is guaranteed. Using synthetic and real MT data, it is shown that the proposed robust estimation methods always yield impedance estimates which are better than the conventional least square (LS) estimation, even under condition of severe noise contamination. A recent development on the constrained robust CSAMT impedance estimation is also discussed. By using synthetic CSAMT data it is demonstrated that the proposed methods can produce usable CSAMT transfer functions for all measurement zones.« less
A Quasi-3-D Theory for Impedance Eduction in Uniform Grazing Flow
NASA Technical Reports Server (NTRS)
Watson, W. R.; Jones, M. G.; Parrott, T. L.
2005-01-01
A 2-D impedance eduction methodology is extended to quasi-3-D sound fields in uniform or shearing mean flow. We introduce a nonlocal, nonreflecting boundary condition to terminate the duct and then educe the impedance by minimizing an objective function. The introduction of a parallel, sparse, equation solver significantly reduces the wall clock time for educing the impedance when compared to that of the sequential band solver used in the 2-D methodology. The accuracy, efficiency, and robustness of the methodology is demonstrated using two examples. In the first example, we show that the method reproduces the known impedance of a ceramic tubular test liner. In the second example, we illustrate that the approach educes the impedance of a four-segment liner where the first, second, and fourth segments consist of a perforated face sheet bonded to honeycomb, and the third segment is a cut from the ceramic tubular test liner. The ability of the method to educe the impedances of multisegmented liners has the potential to significantly reduce the amount of time and cost required to determine the impedance of several uniform liners by allowing them to be placed in series in the test section and to educe the impedance of each segment using a single numerical experiment. Finally, we probe the objective function in great detail and show that it contains a single minimum. Thus, our objective function is ideal for use with local, inexpensive, gradient-based optimizers.
Axisymmetric Wave Transfer Functions of Flexible Tubes
NASA Astrophysics Data System (ADS)
Pinnington, R. J.
1997-07-01
The input and transfer impedances of fluid-filled pipes are calculated by using a wave approach. The pipe walls can have orthotropic elastic properties associated with braided rubber hose. The input and transfer impedances of a water-filled plain rubber hose are plotted for zero pressurization and positive and negative pressure. It is found that the pressure for this case does not greatly affect the stiffness. Input and transfer impedances are also plotted for a braided rubber hose which demonstrates the significant pressure stiffening effects found in practice.
A lumped-circuit model for the radiation impedance of a circular piston in a rigid baffle.
Bozkurt, Ayhan
2008-09-01
The radiation impedance of a piston transducer mounted in a rigid baffle has been widely addressed in the literature. The real and imaginary parts of the impedance are described by the first order Bessel and Struve functions, respectively. Although there are power series expansions for both functions, the analytic formulation of a lumped circuit is not trivial. In this paper, we present an empirical approach to the derivation of a lumped-circuit model for the radiation impedance expression, based on observations on the near-field behavior of stored kinetic and elastic energy. The field analysis is carried out using a finite element method model of the piston and surrounding fluid medium. We show that fluctuations in the real and imaginary components of the impedance can be modeled by series and shunt tank circuits, each of which shape a certain section of the impedance curve. Because the model is composed of lumped-circuit elements, it can be used in circuit simulators. Consequently, the proposed model is useful for the analysis of transducer front-end circuits.
Impedance Eduction in Sound Fields With Peripherally Varying Liners and Flow
NASA Technical Reports Server (NTRS)
Watson, W. R.; Jones, M. G.
2015-01-01
A two-dimensional impedance eduction theory is extended to three-dimensional sound fields and peripherally varying duct liners. The approach is to first measure the acoustic pressure field at a series of flush-mounted wall microphones located around the periphery of the flow duct. The numerical solution for the acoustic pressure field at these microphones is also obtained by solving the three-dimensional convected Helmholtz equation using the finite element method. A quadratic objective function based on the difference between the measured and finite element solution is constructed and the unknown impedance function is obtained by minimizing this objective function. Impedance spectra educed for two uniform-structure liners (a wire-mesh and a conventional liner) and a hard-soft-hard peripherally varying liner (for which the soft segment is that of the conventional liner) are presented. Results are presented at three mean flow Mach numbers and fourteen sound source frequencies. The impedance spectra of the uniform-structure liners are also computed using a two-dimensional impedance eduction theory. The primary conclusions of the study are: 1) when measured data is used with the uniform-structure liners, the three-dimensional theory reproduces the same impedance spectra as the two-dimensional theory except for frequencies corresponding to very low or very high liner attenuation; and 2) good agreement between the educed impedance spectra of the uniform structure conventional liner and the soft segment of the peripherally varying liner is obtained.
Bayesian identification of acoustic impedance in treated ducts.
Buot de l'Épine, Y; Chazot, J-D; Ville, J-M
2015-07-01
The noise reduction of a liner placed in the nacelle of a turbofan engine is still difficult to predict due to the lack of knowledge of its acoustic impedance that depends on grazing flow profile, mode order, and sound pressure level. An eduction method, based on a Bayesian approach, is presented here to adjust an impedance model of the liner from sound pressures measured in a rectangular treated duct under multimodal propagation and flow. The cost function is regularized with prior information provided by Guess's [J. Sound Vib. 40, 119-137 (1975)] impedance of a perforated plate. The multi-parameter optimization is achieved with an Evolutionary-Markov-Chain-Monte-Carlo algorithm.
NASA Astrophysics Data System (ADS)
Wang, Chun; Brunton, Emma; Haghgooie, Saman; Cassells, Kahli; Lowery, Arthur; Rajan, Ramesh
2013-08-01
Objective. Cortical neural prostheses with implanted electrode arrays have been used to restore compromised brain functions but concerns remain regarding their long-term stability and functional performance. Approach. Here we report changes in electrode impedance and stimulation thresholds for a custom-designed electrode array implanted in rat motor cortex for up to three months. Main Results. The array comprises four 2000 µm long electrodes with a large annular stimulating surface (7860-15700 µm2) displaced from the penetrating insulated tip. Compared to pre-implantation in vitro values there were three phases of impedance change: (1) an immediate large increase of impedance by an average of two-fold on implantation; (2) a period of continued impedance increase, albeit with considerable variability, which reached a peak at approximately four weeks post-implantation and remained high over the next two weeks; (3) finally, a period of 5-6 weeks when impedance stabilized at levels close to those seen immediately post-implantation. Impedance could often be temporarily decreased by applying brief trains of current stimulation, used to evoke motor output. The stimulation threshold to induce observable motor behaviour was generally between 75-100 µA, with charge density varying from 48-128 µC cm-2, consistent with the lower current density generated by electrodes with larger stimulating surface area. No systematic change in thresholds occurred over time, suggesting that device functionality was not compromised by the factors that caused changes in electrode impedance. Significance. The present results provide support for the use of annulus electrodes in future applications in cortical neural prostheses.
Electrical characteristics of mammalian cells on porous supports
NASA Astrophysics Data System (ADS)
Chen, Guo
2003-10-01
The quantification of epithelial barrier functions by measuring the trans-epithelial electrical resistance (TER) and using the Electric Cell-substrate Impedance Sensing (ECIS) has been complicated by the current flowing inside the narrow space underneath cells. This thesis work, by examining the electrical characteristics of epithelial cells on porous supports, is aimed to tackle this problem. A mathematical model has been constructed to quantify the impedance from the various sources within a cell/electrode system. This model presents three cell-related parameters, alpha, Rb and Cm: alpha stands for the impedance contribution from the above-mentioned current underneath cells, Rb is an equivalent representation of epithelial barrier functions and Cm denotes the capacitive impedance of cell membranes. Analysis of the three parameters as well as the electrode impedance (Z e) has revealed two experimental approaches to reduce or eliminate the complication of alpha to the deduction of Rb: lowering alpha down to zero or lowering both Ze and alpha. The experimental realization of the first approach has been studied by examining the electrical characteristics of the African green monkey kidney (BS-C-1) and Madin-Darby canine kidney (MDCK-II) cells on porous filters of mixed esters of cellulose or nitrocellulose. A unique setup featuring a plastic/filter/plastic triple-layer structure was constructed to measure the impedance of cells on filters. With the extremely low alpha, all the electrical characteristics can be explained by using an equivalent circuit and Rb can be directly obtained from the resistance difference in the low frequency range. The second approach has been experimentally investigated by examining the electrical characteristics of BS-C-1 cells on porous/rough electrodes, i.e. the gold ECIS electrodes electrochemically coated with conducting polypyrrole/heparin composites or platinum black. Ze and alpha, especially the former, were found to be significantly lowered, which greatly reduces the effect of alpha and yields many new impedance features. Rb can be also directly obtained in a different way from that for the solely lowered alpha on the non-conducting porous filters.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This report was prepared at the request of the Lawrence Livermore Laboratory (LLL) to provide background information for analyzing soil-structure interaction by the frequency-independent impedance function approach. LLL is conducting such analyses as part of its seismic review of selected operating plants under the Systematic Evaluation Program for the US Nuclear Regulatory Commission. The analytical background and basic assumptionsof the impedance function theory are briefly reviewed, and the role of radiation damping in soil-structure interaction analysis is discussed. The validity of modeling soil-structure interaction by using frequency-independent functions is evaluated based on data from several field tests. Finally, the recommendedmore » procedures for performing soil-structure interaction analyses are discussed with emphasis on the modal superposition method.« less
NASA Technical Reports Server (NTRS)
Hahne, G. E.
1991-01-01
A formal theory of the scattering of time-harmonic acoustic scalar waves from impenetrable, immobile obstacles is established. The time-independent formal scattering theory of nonrelativistic quantum mechanics, in particular the theory of the complete Green's function and the transition (T) operator, provides the model. The quantum-mechanical approach is modified to allow the treatment of acoustic-wave scattering with imposed boundary conditions of impedance type on the surface (delta-Omega) of an impenetrable obstacle. With k0 as the free-space wavenumber of the signal, a simplified expression is obtained for the k0-dependent T operator for a general case of homogeneous impedance boundary conditions for the acoustic wave on delta-Omega. All the nonelementary operators entering the expression for the T operator are formally simple rational algebraic functions of a certain invertible linear radiation impedance operator which maps any sufficiently well-behaved complex-valued function on delta-Omega into another such function on delta-Omega. In the subsequent study, the short-wavelength and the long-wavelength behavior of the radiation impedance operator and its inverse (the 'radiation admittance' operator) as two-point kernels on a smooth delta-Omega are studied for pairs of points that are close together.
NASA Astrophysics Data System (ADS)
Avitabile, P.; O'Callahan, J.
2003-07-01
Inclusion of rotational effects is critical for the accuracy of the predicted system characteristics, in almost all system modelling studies. However, experimentally derived information for the description of one or more of the components for the system will generally not have any rotational effects included in the description of the component. The lack of rotational effects has long affected the results from any system model development whether using a modal-based approach or an impedance-based approach. Several new expansion processes are described herein for the development of FRFs needed for impedance-based system models. These techniques expand experimentally derived mode shapes, residual modes from the modal parameter estimation process and FRFs directly to allow for the inclusion of the necessary rotational dof. The FRFs involving translational to rotational dofs are developed as well as the rotational to rotational dof. Examples are provided to show the use of these techniques.
Energy absorption due to spatial resonance of Alfven waves at continuum tip
NASA Astrophysics Data System (ADS)
Chen, Eugene; Berk, Herb; Breizman, Boris; Zheng, Linjin
2011-10-01
We investigate the response of tokamak plasma to an external driving source. An impedance-like function depending on the driving frequency that is growing at a small rate, is calculated and interpreted with different source profiles. Special attention is devoted to the case where driving frequency approaches that of the TAE continuum tip. The calculation can be applied to the estimation of TAE damping rate by analytically continuing the inverse of the impedance function to the lower half plane. The root of the analytic continuation corresponds to the existence of a quasi-mode, from which the damping rate can be found.
How pleasant sounds promote and annoying sounds impede health: a cognitive approach.
Andringa, Tjeerd C; Lanser, J Jolie L
2013-04-08
This theoretical paper addresses the cognitive functions via which quiet and in general pleasurable sounds promote and annoying sounds impede health. The article comprises a literature analysis and an interpretation of how the bidirectional influence of appraising the environment and the feelings of the perceiver can be understood in terms of core affect and motivation. This conceptual basis allows the formulation of a detailed cognitive model describing how sonic content, related to indicators of safety and danger, either allows full freedom over mind-states or forces the activation of a vigilance function with associated arousal. The model leads to a number of detailed predictions that can be used to provide existing soundscape approaches with a solid cognitive science foundation that may lead to novel approaches to soundscape design. These will take into account that louder sounds typically contribute to distal situational awareness while subtle environmental sounds provide proximal situational awareness. The role of safety indicators, mediated by proximal situational awareness and subtle sounds, should become more important in future soundscape research.
A Different Approach to Studying the Charge and Discharge of a Capacitor without an Oscilloscope
ERIC Educational Resources Information Center
Ladino, L. A.
2013-01-01
A different method to study the charging and discharging processes of a capacitor is presented. The method only requires a high impedance voltmeter. The charging and discharging processes of a capacitor are usually studied experimentally using an oscilloscope and, therefore, both processes are studied as a function of time. The approach presented…
Time-domain representation of frequency-dependent foundation impedance functions
Safak, E.
2006-01-01
Foundation impedance functions provide a simple means to account for soil-structure interaction (SSI) when studying seismic response of structures. Impedance functions represent the dynamic stiffness of the soil media surrounding the foundation. The fact that impedance functions are frequency dependent makes it difficult to incorporate SSI in standard time-history analysis software. This paper introduces a simple method to convert frequency-dependent impedance functions into time-domain filters. The method is based on the least-squares approximation of impedance functions by ratios of two complex polynomials. Such ratios are equivalent, in the time-domain, to discrete-time recursive filters, which are simple finite-difference equations giving the relationship between foundation forces and displacements. These filters can easily be incorporated into standard time-history analysis programs. Three examples are presented to show the applications of the method.
Acoustic metamaterials with broadband and wide-angle impedance matching
NASA Astrophysics Data System (ADS)
Liu, Chenkai; Luo, Jie; Lai, Yun
2018-04-01
We propose a general approach to design broadband and wide-angle impedance-matched acoustic metamaterials. Such an unusual acoustic impedance matching characteristic can be well explained by using a spatially dispersive effective medium theory. For demonstrations, we used silicone rubber, which has a huge impedance contrast with water, to design one- and two-dimensional acoustic structures which are almost perfectly impedance matched to water for a wide range of incident angles and in a broad frequency band. Our work opens up an approach to realize extraordinary acoustic impedance matching properties via metamaterial-design techniques.
NASA Astrophysics Data System (ADS)
Lucas, G.; Love, J. J.; Kelbert, A.; Bedrosian, P.; Rigler, E. J.
2017-12-01
Space weather induces significant geoelectric fields within Earth's subsurface that can adversely affect electric power grids. The complex interaction between space weather and the solid Earth has traditionally been approached with the use of simple 1-D impedance functions relating the inducing magnetic field to the induced geoelectric field. Ongoing data collection through the NSF EarthScope program has produced measured impedance data across much of the continental US. In this work, impedance data are convolved with magnetic field variations, obtained from USGS magnetic observatories, during a geomagnetic storm. This convolution produces geoelectric fields within the earth. These geoelectric fields are then integrated across power transmission lines to determine the voltage generated within each power line as a function of time during a geomagnetic storm. The voltages generated within the electric power grid will be shown for several historic geomagnetic storms. The estimated voltages calculated from 1-D and 3-D impedances differ by more than 100 V across some transmission lines. In combination with grounding resistance data and network topology, these voltage estimates can be utilized by power companies to estimate geomagnetically-induced currents throughout the network. These voltage estimates can provide information on which power lines are most vulnerable to geomagnetic storms, and assist power grid companies investigating where to install additional protections within their grid.
How Pleasant Sounds Promote and Annoying Sounds Impede Health: A Cognitive Approach
Andringa, Tjeerd C.; Lanser, J. Jolie L.
2013-01-01
This theoretical paper addresses the cognitive functions via which quiet and in general pleasurable sounds promote and annoying sounds impede health. The article comprises a literature analysis and an interpretation of how the bidirectional influence of appraising the environment and the feelings of the perceiver can be understood in terms of core affect and motivation. This conceptual basis allows the formulation of a detailed cognitive model describing how sonic content, related to indicators of safety and danger, either allows full freedom over mind-states or forces the activation of a vigilance function with associated arousal. The model leads to a number of detailed predictions that can be used to provide existing soundscape approaches with a solid cognitive science foundation that may lead to novel approaches to soundscape design. These will take into account that louder sounds typically contribute to distal situational awareness while subtle environmental sounds provide proximal situational awareness. The role of safety indicators, mediated by proximal situational awareness and subtle sounds, should become more important in future soundscape research. PMID:23567255
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirby, R. Jason
2016-08-15
Cardiac safety assays incorporating label-free detection of human stem-cell derived cardiomyocyte contractility provide human relevance and medium throughput screening to assess compound-induced cardiotoxicity. In an effort to provide quantitative analysis of the large kinetic datasets resulting from these real-time studies, we applied bioinformatic approaches based on nonlinear dynamical system analysis, including limit cycle analysis and autocorrelation function, to systematically assess beat irregularity. The algorithms were integrated into a software program to seamlessly generate results for 96-well impedance-based data. Our approach was validated by analyzing dose- and time-dependent changes in beat patterns induced by known proarrhythmic compounds and screening a cardiotoxicitymore » library to rank order compounds based on their proarrhythmic potential. We demonstrate a strong correlation for dose-dependent beat irregularity monitored by electrical impedance and quantified by autocorrelation analysis to traditional manual patch clamp potency values for hERG blockers. In addition, our platform identifies non-hERG blockers known to cause clinical arrhythmia. Our method provides a novel suite of medium-throughput quantitative tools for assessing compound effects on cardiac contractility and predicting compounds with potential proarrhythmia and may be applied to in vitro paradigms for pre-clinical cardiac safety evaluation. - Highlights: • Impedance-based monitoring of human iPSC-derived cardiomyocyte contractility • Limit cycle analysis of impedance data identifies aberrant oscillation patterns. • Nonlinear autocorrelation function quantifies beat irregularity. • Identification of hERG and non-hERG inhibitors with known risk of arrhythmia • Automated software processes limit cycle and autocorrelation analyses of 96w data.« less
NASA Astrophysics Data System (ADS)
Abele, John E.
1989-08-01
Electrical impedance has been one of the many "tools of great promise" that physicians have employed in their quest to measure and/or monitor body function or physiologic events. So far, the expectations for its success have always exceeded its performance. In simplistic terms, physiologic impedance is a measure of the resistance in the volume between electrodes which changes as a function of changes in that volume, the relative impedance of that volume, or a combination of these two. The history and principles of electrical impedance are very nicely reviewed by Geddes and Baker in their textbook "Principles of Applied Biomedical Instrumentation". It is humbling, however, to note that Cremer recorded variations in electrical impedance in frog hearts as early as 1907. The list of potential applications includes the measurement of thyroid function, estrogen activity, galvanic skin reflex, respiration, blood flow by conductivity dilution, nervous activity and eye movement. Commercial devices employing impedance have been and are being used to measure respiration (pneumographs and apneamonitors), pulse volume (impedance phlebographs) and even noninvasive cardiac output.
A Rayleighian approach for modeling kinetics of ionic transport in polymeric media
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumar, Rajeev
2017-02-14
Here, we report a theoretical approach for analyzing impedance of ionic liquids (ILs) and charged polymers such as polymerized ionic liquids (PolyILs) within linear response. The approach is based on the Rayleigh dissipation function formalism, which provides a computational framework for a systematic study of various factors, including polymer dynamics, in affecting the impedance. We present an analytical expression for the impedance within linear response by constructing a one-dimensional model for ionic transport in ILs/PolyILs. This expression is used to extract mutual diffusion constants, the length scale of mutual diffusion, and thicknesses of a low-dielectric layer on the electrodes frommore » the broadband dielectric spectroscopy (BDS) measurements done for an IL and three PolyILs. Also, static dielectric permittivities of the IL and the PolyILs are determined. The extracted mutual diffusion constants are compared with the self diffusion constants of ions measured using pulse field gradient (PFG) fluorine nuclear magnetic resonance (NMR). For the first time, excellent agreements between the diffusivities extracted from the Electrode Polarization spectra (EPS) of IL/PolyILs and those measured using the PFG-NMR are found, which allows the use of the EPS and the PFG-NMR techniques in a complimentary manner for a general understanding of the ionic transport.« less
Model Parameterization and P-wave AVA Direct Inversion for Young's Impedance
NASA Astrophysics Data System (ADS)
Zong, Zhaoyun; Yin, Xingyao
2017-05-01
AVA inversion is an important tool for elastic parameters estimation to guide the lithology prediction and "sweet spot" identification of hydrocarbon reservoirs. The product of the Young's modulus and density (named as Young's impedance in this study) is known as an effective lithology and brittleness indicator of unconventional hydrocarbon reservoirs. Density is difficult to predict from seismic data, which renders the estimation of the Young's impedance inaccurate in conventional approaches. In this study, a pragmatic seismic AVA inversion approach with only P-wave pre-stack seismic data is proposed to estimate the Young's impedance to avoid the uncertainty brought by density. First, based on the linearized P-wave approximate reflectivity equation in terms of P-wave and S-wave moduli, the P-wave approximate reflectivity equation in terms of the Young's impedance is derived according to the relationship between P-wave modulus, S-wave modulus, Young's modulus and Poisson ratio. This equation is further compared to the exact Zoeppritz equation and the linearized P-wave approximate reflectivity equation in terms of P- and S-wave velocities and density, which illustrates that this equation is accurate enough to be used for AVA inversion when the incident angle is within the critical angle. Parameter sensitivity analysis illustrates that the high correlation between the Young's impedance and density render the estimation of the Young's impedance difficult. Therefore, a de-correlation scheme is used in the pragmatic AVA inversion with Bayesian inference to estimate Young's impedance only with pre-stack P-wave seismic data. Synthetic examples demonstrate that the proposed approach is able to predict the Young's impedance stably even with moderate noise and the field data examples verify the effectiveness of the proposed approach in Young's impedance estimation and "sweet spots" evaluation.
NASA Astrophysics Data System (ADS)
Castaneda-Lopez, Homero
A methodology for detecting and locating defects or discontinuities on the outside covering of coated metal underground pipelines subjected to cathodic protection has been addressed. On the basis of wide range AC impedance signals for various frequencies applied to a steel-coated pipeline system and by measuring its corresponding transfer function under several laboratory simulation scenarios, a physical laboratory setup of an underground cathodic-protected, coated pipeline was built. This model included different variables and elements that exist under real conditions, such as soil resistivity, soil chemical composition, defect (holiday) location in the pipeline covering, defect area and geometry, and level of cathodic protection. The AC impedance data obtained under different working conditions were used to fit an electrical transmission line model. This model was then used as a tool to fit the impedance signal for different experimental conditions and to establish trends in the impedance behavior without the necessity of further experimental work. However, due to the chaotic nature of the transfer function response of this system under several conditions, it is believed that non-deterministic models based on pattern recognition algorithms are suitable for field condition analysis. A non-deterministic approach was used for experimental analysis by applying an artificial neural network (ANN) algorithm based on classification analysis capable of studying the pipeline system and differentiating the variables that can change impedance conditions. These variables include level of cathodic protection, location of discontinuities (holidays), and severity of corrosion. This work demonstrated a proof-of-concept for a well-known technique and a novel algorithm capable of classifying impedance data for experimental results to predict the exact location of the active holidays and defects on the buried pipelines. Laboratory findings from this procedure are promising, and efforts to develop it for field conditions should continue.
Development of a Multifidelity Approach to Acoustic Liner Impedance Eduction
NASA Technical Reports Server (NTRS)
Nark, Douglas M.; Jones, Michael G.
2017-01-01
The use of acoustic liners has proven to be extremely effective in reducing aircraft engine fan noise transmission/radiation. However, the introduction of advanced fan designs and shorter engine nacelles has highlighted a need for novel acoustic liner designs that provide increased fan noise reduction over a broader frequency range. To achieve aggressive noise reduction goals, advanced broadband liner designs, such as zone liners and variable impedance liners, will likely depart from conventional uniform impedance configurations. Therefore, educing the impedance of these axial- and/or spanwise-variable impedance liners will require models that account for three-dimensional effects, thereby increasing computational expense. Thus, it would seem advantageous to investigate the use of multifidelity modeling approaches to impedance eduction for these advanced designs. This paper describes an extension of the use of the CDUCT-LaRC code to acoustic liner impedance eduction. The proposed approach is applied to a hardwall insert and conventional liner using simulated data. Educed values compare well with those educed using two extensively tested and validated approaches. The results are very promising and provide justification to further pursue the complementary use of CDUCT-LaRC with the currently used finite element codes to increase the efficiency of the eduction process for configurations involving three-dimensional effects.
Delayed changes in auditory status in cochlear implant users with preserved acoustic hearing.
Scheperle, Rachel A; Tejani, Viral D; Omtvedt, Julia K; Brown, Carolyn J; Abbas, Paul J; Hansen, Marlan R; Gantz, Bruce J; Oleson, Jacob J; Ozanne, Marie V
2017-07-01
This retrospective review explores delayed-onset hearing loss in 85 individuals receiving cochlear implants designed to preserve acoustic hearing at the University of Iowa Hospitals and Clinics between 2001 and 2015. Repeated measures of unaided behavioral audiometric thresholds, electrode impedance, and electrically evoked compound action potential (ECAP) amplitude growth functions were used to characterize longitudinal changes in auditory status. Participants were grouped into two primary categories according to changes in unaided behavioral thresholds: (1) stable hearing or symmetrical hearing loss and (2) delayed loss of hearing in the implanted ear. Thirty-eight percent of this sample presented with delayed-onset hearing loss of various degrees and rates of change. Neither array type nor insertion approach (round window or cochleostomy) had a significant effect on prevalence. Electrode impedance increased abruptly for many individuals exhibiting precipitous hearing loss; the increase was often transient. The impedance increases were significantly larger than the impedance changes observed for individuals with stable or symmetrical hearing loss. Moreover, the impedance changes were associated with changes in behavioral thresholds for individuals with a precipitous drop in behavioral thresholds. These findings suggest a change in the electrode environment coincident with the change in auditory status. Changes in ECAP thresholds, growth function slopes, and suprathreshold amplitudes were not correlated with changes in behavioral thresholds, suggesting that neural responsiveness in the region excited by the implant is relatively stable. Further exploration into etiology of delayed-onset hearing loss post implantation is needed, with particular interest in mechanisms associated with changes in the intracochlear environment. Copyright © 2017 Elsevier B.V. All rights reserved.
Quality factor concept in piezoceramic transformer performance description.
Mezheritsky, Alex V
2006-02-01
A new general approach based on the quality factor concept to piezoceramic transformer (PT) performance description is proposed. The system's quality factor, material elastic anisotropy, and coupling factors of the input and output sections of an electrically excited and electrically loaded PT fully characterize its resonance and near-resonance behavior. The PT efficiency, transformation ratio, and input and output power were analytically analyzed and simulated as functions of the load and frequency for the simplest classical Langevin-type and Rosen-type PT designs. A new formulation of the electrical input impedance allows one to separate the power consumed by PT from the power transferred into the load. The system's PT quality factor takes into account losses in each PT "input-output-load" functional components. The loading process is changing PT input electrical impedance on the way that under loading the minimum series impedance is increasing and the maximum parallel impedance is decreasing coincidentally. The quality-factors ratio, between the states of fully loaded and nonloaded PT, is one of the best measures of PTs dynamic performance--practically, the lower the ratio is, the better PT efficiency. A simple and effective method for the loaded PT quality factor determination is proposed. As was found, a piezoceramic with low piezoelectric anisotropy is required to provide maximum PT efficiency and higher corresponding voltage gain. Limitations on the PT output voltage and power, caused by nonlinear effects in piezoceramics, were established.
Gudra, Tadeusz; Opieliński, Krzysztof J
2002-05-01
In different solutions of ultrasonic transducers radiating acoustic energy into the air there occurs the problem of the proper selection of the acoustic impedance of one or more matching layers. The goal of this work was a computer analysis of the influence of acoustic impedance on the transfer function of piezoceramic transducers equipped with matching layers. Cases of resonance and non-resonance matching impedance in relation to the transfer function and the energy transmission coefficient for solid state-air systems were analysed. With stable thickness of matching layers the required shape of the transfer function can be obtained through proper choice of acoustic impedance were built (e.g. maximal flat function). The proper choice of acoustic impedance requires an elaboration of precise methods of synthesis of matching systems. Using the known matching criteria (Chebyshev's, DeSilets', Souquet's), the transfer function characteristics of transducers equipped with one, two, and three matching layers as well as the optimisation methods of the energy transmission coefficient were presented. The influence of the backside load of the transducer on the shape of transfer function was also analysed. The calculation results of this function for different loads of the transducer backside without and with the different matching layers were presented. The proper load selection allows us to obtain the desired shape of the transfer function, which determines the pulse shape generated by the transducer.
Frazzoni, Leonardo; Frazzoni, Marzio; de Bortoli, Nicola; Tolone, Salvatore; Martinucci, Irene; Fuccio, Lorenzo; Savarino, Vincenzo; Savarino, Edoardo
2018-01-01
The Rome IV Committee introduced a major change in the classification of functional gastrointestinal disorders, proposing a more restrictive definition of gastroesophageal reflux disease (GERD). It was suggested that hypersensitive esophagus (HE) may sit more firmly within the functional realm. It was suggested that GERD diagnosis should be based upon abnormal acid exposure time (AET) only, implying no advantage of impedance-pH over pH monitoring. Symptom association probability (SAP), symptom index (SI) and heartburn relief with proton pump inhibitor (PPI) therapy were regarded as unreliable, whereas a lack of response to PPI was considered as evidence of functional heartburn. These assumptions are contradicted by numerous studies showing the clinical relevance of weakly acidic refluxes and the diagnostic utility of SAP, SI and new impedance parameters, namely the post-reflux swallow-induced peristaltic wave (PSPW) index and the mean nocturnal baseline impedance (MNBI). The PSPW index and MNBI provide significant diagnostic advantage, particularly in patients with normal AET who can be classified as HE when both parameters are abnormal, even though SAP and SI are negative. Visceral pain modulators are recommended by the Rome IV Committee despite scanty evidence of efficacy, but a positive outcome with medical or surgical anti-reflux treatment has been reported by several studies of HE patients. Therefore, we believe that patients with endoscopy-negative heartburn should be investigated by means of impedance-pH monitoring with analysis of PSPW index and MNBI: such an approach provides accurate identification of HE cases, who remain, in our opinion, within the realm of GERD and should be treated accordingly. PMID:29333061
NASA Astrophysics Data System (ADS)
Cao, Pei; Qi, Shuai; Tang, J.
2018-03-01
The impedance/admittance measurements of a piezoelectric transducer bonded to or embedded in a host structure can be used as damage indicator. When a credible model of the healthy structure, such as the finite element model, is available, using the impedance/admittance change information as input, it is possible to identify both the location and severity of damage. The inverse analysis, however, may be under-determined as the number of unknowns in high-frequency analysis is usually large while available input information is limited. The fundamental challenge thus is how to find a small set of solutions that cover the true damage scenario. In this research we cast the damage identification problem into a multi-objective optimization framework to tackle this challenge. With damage locations and severities as unknown variables, one of the objective functions is the difference between impedance-based model prediction in the parametric space and the actual measurements. Considering that damage occurrence generally affects only a small number of elements, we choose the sparsity of the unknown variables as another objective function, deliberately, the l 0 norm. Subsequently, a multi-objective Dividing RECTangles (DIRECT) algorithm is developed to facilitate the inverse analysis where the sparsity is further emphasized by sigmoid transformation. As a deterministic technique, this approach yields results that are repeatable and conclusive. In addition, only one algorithmic parameter, the number of function evaluations, is needed. Numerical and experimental case studies demonstrate that the proposed framework is capable of obtaining high-quality damage identification solutions with limited measurement information.
NASA Astrophysics Data System (ADS)
Debenjak, Andrej; Boškoski, Pavle; Musizza, Bojan; Petrovčič, Janko; Juričić, Đani
2014-05-01
This paper proposes an approach to the estimation of PEM fuel cell impedance by utilizing pseudo-random binary sequence as a perturbation signal and continuous wavelet transform with Morlet mother wavelet. With the approach, the impedance characteristic in the frequency band from 0.1 Hz to 500 Hz is identified in 60 seconds, approximately five times faster compared to the conventional single-sine approach. The proposed approach was experimentally evaluated on a single PEM fuel cell of a larger fuel cell stack. The quality of the results remains at the same level compared to the single-sine approach.
NASA Technical Reports Server (NTRS)
Gordy, R. S.
1972-01-01
An improved broadband impedance matching technique was developed. The technique is capable of resolving points in the waveguide which generate reflected energy. A version of the comparison reflectometer was developed and fabricated to determine the mean amplitude of the reflection coefficient excited at points in the guide as a function of distance, and the complex reflection coefficient of a specific discontinuity in the guide as a function of frequency. An impedance matching computer program was developed which is capable of impedance matching the characteristics of each disturbance independent of other reflections in the guide. The characteristics of four standard matching elements were compiled, and their associated curves of reflection coefficient and shunt susceptance as a function of frequency are presented. It is concluded that an economical, fast, and reliable impedance matching technique has been established which can provide broadband impedance matches.
Oscillation mechanics of the respiratory system.
Bates, Jason H T; Irvin, Charles G; Farré, Ramon; Hantos, Zoltán
2011-07-01
The mechanical impedance of the respiratory system defines the pressure profile required to drive a unit of oscillatory flow into the lungs. Impedance is a function of oscillation frequency, and is measured using the forced oscillation technique. Digital signal processing methods, most notably the Fourier transform, are used to calculate impedance from measured oscillatory pressures and flows. Impedance is a complex function of frequency, having both real and imaginary parts that vary with frequency in ways that can be used empirically to distinguish normal lung function from a variety of different pathologies. The most useful diagnostic information is gained when anatomically based mathematical models are fit to measurements of impedance. The simplest such model consists of a single flow-resistive conduit connecting to a single elastic compartment. Models of greater complexity may have two or more compartments, and provide more accurate fits to impedance measurements over a variety of different frequency ranges. The model that currently enjoys the widest application in studies of animal models of lung disease consists of a single airway serving an alveolar compartment comprising tissue with a constant-phase impedance. This model has been shown to fit very accurately to a wide range of impedance data, yet contains only four free parameters, and as such is highly parsimonious. The measurement of impedance in human patients is also now rapidly gaining acceptance, and promises to provide a more comprehensible assessment of lung function than parameters derived from conventional spirometry. © 2011 American Physiological Society.
NASA Astrophysics Data System (ADS)
Arslanagic, S.; Hansen, T. V.; Mortensen, N. A.; Gregersen, A. H.; Sigmund, O.; Ziolkowski, R. W.; Breinbjerg, O.
2013-04-01
The scattering parameter extraction method of metamaterial homogenization is reviewed to show that the only ambiguity is the one related to the choice of the branch of the complex logarithmic function (or the complex inverse cosine function), whereas it has no ambiguity for the sign of the wave number and intrinsic impedance. While the method indeed yields two signs of the intrinsic impedance, and thus the wave number, the signs are dependent, and moreover, both sign combinations lead to the same permittivity and permeability, and are thus permissible. This observation is in distinct contrast to a number of statements in the literature where the correct sign of the intrinsic impedance and wave number, resulting from the scattering parameter method, is chosen by imposing additional physical requirements such as passivity. The scattering parameter method is reviewed through an investigation of a uniform plane wave normally incident on a planar slab in free-space, and the severity of the branch ambiguity is illustrated through simulations of a known metamaterial realization. Several approaches for proper branch selection are reviewed and their suitability to metamaterial samples is discussed.
Bioimpedance imaging: an overview of potential clinical applications.
Bayford, Richard; Tizzard, Andrew
2012-10-21
Electrical Impedance Tomography (EIT) is an imaging technique based on multiple bio impedance measurements to produce a map (image) of impedance or changes in impedance across a region. Its origins lay in geophysics where it is still used to today. This review highlights potential clinical applications of EIT. Beginning with a brief overview of the underlying principles behind the modality, it describes the background research leading towards the development of the application of EIT for monitoring pulmonary function, detecting and localising tumours and monitoring brain function.
Savarino, Edoardo; Marabotto, Elisa; Zentilin, Patrizia; Frazzoni, Marzio; Sammito, Giorgio; Bonfanti, Daria; Sconfienza, Luca; Assandri, Lorenzo; Gemignani, Lorenzo; Malesci, Alberto; Savarino, Vincenzo
2011-07-01
Functional heartburn is defined by Rome III criteria as an endoscopy-negative condition with normal oesophageal acid exposure time, negative symptom association to acid reflux and unsatisfactory response to proton pump inhibitors. These criteria underestimated the role of non-acid reflux. To assess the contribution of impedance-pH with symptom association probability (SAP) analysis in identifying endoscopy-negative patients with reflux disease and separating them from functional heartburn. Consecutive endoscopy-negative patients treated with proton pump inhibitors (n=219) undergoing impedance-pH monitoring off-therapy were analysed. Distal acid exposure time, reflux episodes, SAP and symptomatic response to proton pump inhibitors were measured. Based on impedance-pH/SAP, 67 (31%) patients were pH+/SAP+, 6 (2%) pH+/SAP-, 83 (38%) hypersensitive oesophagus and 63 (29%) functional heartburn. According to pH-metry alone/response to proton pump inhibitors, 62 (28%) were pH+/SAP+, 11 (5%) pH+/SAP-, 61 (28%) hypersensitive oesophagus and 85 (39%) functional heartburn. In the normal-acid exposure population the contribution of impedance-pH/SAP compared to pH-metry alone/response to proton pump inhibitors in identifying patients with reflux disease and functional heartburn resulted to be 10%. In patients with abnormal-acid exposure, the contribution of impedance-pH/SAP increased by 3%. Comparing impedance-pH testing with pH-metry alone plus the response to proton pump inhibitor therapy demonstrated that the latter ones cause underestimation of reflux disease patients and overestimation of functional heartburn patients. Copyright © 2011 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
DISTRIBUTED RC NETWORKS WITH RATIONAL TRANSFER FUNCTIONS,
A distributed RC circuit analogous to a continuously tapped transmission line can be made to have a rational short-circuit transfer admittance and...one rational shortcircuit driving-point admittance. A subcircuit of the same structure has a rational open circuit transfer impedance and one rational ...open circuit driving-point impedance. Hence, rational transfer functions may be obtained while considering either generator impedance or load
NASA Astrophysics Data System (ADS)
Kalscheuer, Thomas; Juhojuntti, Niklas; Vaittinen, Katri
2017-12-01
A combination of magnetotelluric (MT) measurements on the surface and in boreholes (without metal casing) can be expected to enhance resolution and reduce the ambiguity in models of electrical resistivity derived from MT surface measurements alone. In order to quantify potential improvement in inversion models and to aid design of electromagnetic (EM) borehole sensors, we considered two synthetic 2D models containing ore bodies down to 3000 m depth (the first with two dipping conductors in resistive crystalline host rock and the second with three mineralisation zones in a sedimentary succession exhibiting only moderate resistivity contrasts). We computed 2D inversion models from the forward responses based on combinations of surface impedance measurements and borehole measurements such as (1) skin-effect transfer functions relating horizontal magnetic fields at depth to those on the surface, (2) vertical magnetic transfer functions relating vertical magnetic fields at depth to horizontal magnetic fields on the surface and (3) vertical electric transfer functions relating vertical electric fields at depth to horizontal magnetic fields on the surface. Whereas skin-effect transfer functions are sensitive to the resistivity of the background medium and 2D anomalies, the vertical magnetic and electric field transfer functions have the disadvantage that they are comparatively insensitive to the resistivity of the layered background medium. This insensitivity introduces convergence problems in the inversion of data from structures with strong 2D resistivity contrasts. Hence, we adjusted the inversion approach to a three-step procedure, where (1) an initial inversion model is computed from surface impedance measurements, (2) this inversion model from surface impedances is used as the initial model for a joint inversion of surface impedances and skin-effect transfer functions and (3) the joint inversion model derived from the surface impedances and skin-effect transfer functions is used as the initial model for the inversion of the surface impedances, skin-effect transfer functions and vertical magnetic and electric transfer functions. For both synthetic examples, the inversion models resulting from surface and borehole measurements have higher similarity to the true models than models computed exclusively from surface measurements. However, the most prominent improvements were obtained for the first example, in which a deep small-sized ore body is more easily distinguished from a shallow main ore body penetrated by a borehole and the extent of the shadow zone (a conductive artefact) underneath the main conductor is strongly reduced. Formal model error and resolution analysis demonstrated that predominantly the skin-effect transfer functions improve model resolution at depth below the sensors and at distance of ˜ 300-1000 m laterally off a borehole, whereas the vertical electric and magnetic transfer functions improve resolution along the borehole and in its immediate vicinity. Furthermore, we studied the signal levels at depth and provided specifications of borehole magnetic and electric field sensors to be developed in a future project. Our results suggest that three-component SQUID and fluxgate magnetometers should be developed to facilitate borehole MT measurements at signal frequencies above and below 1 Hz, respectively.
Khor, Joo Moy; Tizzard, Andrew; Demosthenous, Andreas; Bayford, Richard
2014-06-01
Electrical impedance tomography (EIT) could be significantly advantageous to continuous monitoring of lung development in newborn and, in particular, preterm infants as it is non-invasive and safe to use within the intensive care unit. It has been demonstrated that accurate boundary form of the forward model is important to minimize artefacts in reconstructed electrical impedance images. This paper presents the outcomes of initial investigations for acquiring patient-specific thorax boundary information using a network of flexible sensors that imposes no restrictions on the patient's normal breathing and movements. The investigations include: (1) description of the basis of the reconstruction algorithms, (2) tests to determine a minimum number of bend sensors, (3) validation of two approaches to reconstruction and (4) an example of a commercially available bend sensor and its performance. Simulation results using ideal sensors show that, in the worst case, a total shape error of less than 6% with respect to its total perimeter can be achieved.
Bockman, Alexander; Fackler, Cameron; Xiang, Ning
2015-04-01
Acoustic performance for an interior requires an accurate description of the boundary materials' surface acoustic impedance. Analytical methods may be applied to a small class of test geometries, but inverse numerical methods provide greater flexibility. The parameter estimation problem requires minimizing prediction vice observed acoustic field pressure. The Bayesian-network sampling approach presented here mitigates other methods' susceptibility to noise inherent to the experiment, model, and numerics. A geometry agnostic method is developed here and its parameter estimation performance is demonstrated for an air-backed micro-perforated panel in an impedance tube. Good agreement is found with predictions from the ISO standard two-microphone, impedance-tube method, and a theoretical model for the material. Data by-products exclusive to a Bayesian approach are analyzed to assess sensitivity of the method to nuisance parameters.
Prediction and reduction of aircraft noise in outdoor environments
NASA Astrophysics Data System (ADS)
Tong, Bao N.
This dissertation investigates the noise due to an en-route aircraft cruising at high altitudes. It offers an improved understanding into the combined effects of atmospheric propagation, ground reflection, and source motion on the impact of en-route aircraft noise. A numerical model has been developed to compute pressure time-histories due to a uniformly moving source above a flat ground surface in the presence of a horizontally stratified atmosphere. For a moving source at high elevations, contributions from a direct and specularly reflected wave are sufficient in predicting the sound field close to the ground. In the absence of wind effects, the predicted sound field from a single overhead flight trajectory can be used to interpolate pressure time histories at all other receiver locations via a simplified ray model for the incoherent sound field. This approach provides an efficient method for generating pressure time histories in a three-dimensional space for noise impact studies. A variety of different noise propagation methods are adapted to a uniformly moving source to evaluate the accuracy and efficiency of their predictions. The techniques include: analytical methods, the Fast Field Program (FFP), and asymptotic analysis methods (e.g., ray tracing and more advanced formulations). Source motion effects are introduced via either a retarded time analysis or a Lorentz transform approach depending on the complexity of the problem. The noise spectrum from a single emission frequency, moving source has broadband characteristics. This is a consequence of the Doppler shift which continuously modifies the perceived frequency of the source as it moves relative to a stationary observer on the ground. Thus, the instantaneous wavefronts must be considered in both the frequency dependent ground impedance model and the atmospheric absorption model. It can be shown that the Doppler factor is invariant along each ray path. This gives rise to a path dependent atmospheric absorption mechanism due to the source's motion. To help mitigate the noise that propagates to the ground, multi-layered acoustic treatments can be applied to provide good performance over a wide range of frequencies. An accurate representation of material properties for each of the constituent layers is needed in the design of such treatments. The parameter of interest is the specific acoustic impedance, which can be obtained via inversion of acoustic transfer function measurements. However, several different impedance values can correspond to the same sound field predictions. The boundary loss factor F (associated with spherical wave reflection) is the source of this ambiguity. A method for identifying the family of solutions and selecting the physically meaningful branch is proposed to resolve this non-uniqueness issue. Accurate deduction of the acoustic impedance depends on precise measurements of the acoustic transfer function. However, measurement uncertainties exists in both the magnitude and the phase of the acoustic transfer function. The ASA/ANSI S1.18 standard impedance deduction method uses phase information, which can be unreliable in many outdoor environments. An improved technique which only relies on magnitude information is developed in this dissertation. A selection of optimal geometries become necessary to reduce the sensitivity of the deduced impedance to small variations in the measured data. A graphical approach is provided which offers greater insight into the optimization problem. A downhill simplex algorithm has been implemented to automate the impedance deduction procedure. Physical constraints are applied to limit the search region and to eliminate rogue solutions. Several case studies consisting of both indoor and outdoor acoustical measurements are presented to validate the proposed technique. The current analysis is limited to locally reacting materials where the acoustic impedance does not depend on the incidence angle of the reflected wave.
Dynamic modeling and parameter estimation of a radial and loop type distribution system network
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jun Qui; Heng Chen; Girgis, A.A.
1993-05-01
This paper presents a new identification approach to three-phase power system modeling and model reduction taking power system network as multi-input, multi-output (MIMO) processes. The model estimate can be obtained in discrete-time input-output form, discrete- or continuous-time state-space variable form, or frequency-domain impedance transfer function matrix form. An algorithm for determining the model structure of this MIMO process is described. The effect of measurement noise on the approach is also discussed. This approach has been applied on a sample system and simulation results are also presented in this paper.
Mudraia, I S; Kirpatovskiĭ, V I
1993-01-01
The paper describes impedance methods of investigating upper urinary tracts (UUT) which may serve adjuvants in the diagnosis of the urinary tract wall disturbances due to diseases caused by impaired urine evacuation from the kidney and which may prove helpful in the choice of therapeutic policy, evaluation of the postoperative period and outcomes prognosis. UUT impedance tests can be performed during endoscopic manipulations or under open operative interventions. Two-frequency impedancemetry allows rapid detection of non-functioning UUT parts or sclerosal sites of the UUT wall, relevant criteria being the ratio of basic impedances of the site under low and high scanning current. This value is computed by an urological two-frequency impedancemeter IDU-M. To assess the UUT wall functionally, use should be made of 6-channel urological rheograph REUR-6 providing multichannel registration of immediate impedance ureterograms. In this manner one can obtain qualitative and quantitative assessment of the ureteral peristalsis through its all length, the criteria being the amplitude of impedance ureterographic complexes, their shape, duration, frequency, rhythm, sequence and rate of distribution. Loading tests increase the accuracy of UUT impedance measurements, are able to define compensatory reserves of the wall contractility. The introduction of rheological methods in urological practice makes broader the armory of diagnostic techniques in urology, upgrade pathogenetic validity of surgical and therapeutic measures.
[System analytical approach of lung function and hemodynamics].
Naszlady, Attila; Kiss, Lajos
2009-02-15
The authors critically analyse the traditional views in physiology and complete them with new statements based on computer model simulations of lung function and of hemodynamics. Conclusions are derived for the clinical practice as follows: the four-dimensional function curves are similar in both systems; there is a "waterfall" zone in the pulmonary blood perfusion; the various time constants of pulmonary regions can modify the blood gas values; pulmonary capillary pressure is equal to pulmonary arterial diastole pressure; heart is not a pressure pump, but a flow source; ventricles are loaded by the input impedance of the arterial systems and not by the total vascular (ohmlike) resistance; optimum heart rate in rest depends on the length of the aorta; this law of heart rate, based on the principle of resonance is valid along the mammalian allometric line; tachycardia decreases the input impedance; using positive end expiratory pressure respirators the blood gas of pulmonary artery should be followed; coronary circulation should be assessed in beat per milliliter, the milliliter per minute may be false. These statements are compared to related references.
Evaluation of a cost-effective loads approach. [shock spectra/impedance method for Viking Orbiter
NASA Technical Reports Server (NTRS)
Garba, J. A.; Wada, B. K.; Bamford, R.; Trubert, M. R.
1976-01-01
A shock spectra/impedance method for loads predictions is used to estimate member loads for the Viking Orbiter, a 7800-lb interplanetary spacecraft that has been designed using transient loads analysis techniques. The transient loads analysis approach leads to a lightweight structure but requires complex and costly analyses. To reduce complexity and cost, a shock spectra/impedance method is currently being used to design the Mariner Jupiter Saturn spacecraft. This method has the advantage of using low-cost in-house loads analysis techniques and typically results in more conservative structural loads. The method is evaluated by comparing the increase in Viking member loads to the loads obtained by the transient loads analysis approach. An estimate of the weight penalty incurred by using this method is presented. The paper also compares the calculated flight loads from the transient loads analyses and the shock spectra/impedance method to measured flight data.
Macridin, Alexandru; Spentzouris, Panagiotis; Amundson, James; ...
2011-06-28
We calculate the impedance and wake functions for laminated structures with parallel-plane and circular geometries. We critically examine the approximations used in the literature for the coupling impedance in laminated chambers and find that most of them are not justified because the wall surface impedance is large. A comparison between flat and circular geometry impedances is presented. We apply our calculation in a state-of-the-art beam dynamics simulation of the Fermilab Booster which includes nonlinear optics, laminated wakefields, and space charge impedance. The latter can have a significant effect away from the ultrarelativistic limit. Even though the simulations and the comparisonmore » with the experiment are done at the Booster injection energy, where the relativistic factor γ = 1.42, we find good agreement between our calculation of the coherent tune shift and recent experimental measurements.« less
Broadband electrical impedance matching for piezoelectric ultrasound transducers.
Huang, Haiying; Paramo, Daniel
2011-12-01
This paper presents a systematic method for designing broadband electrical impedance matching networks for piezoelectric ultrasound transducers. The design process involves three steps: 1) determine the equivalent circuit of the unmatched piezoelectric transducer based on its measured admittance; 2) design a set of impedance matching networks using a computerized Smith chart; and 3) establish the simulation model of the matched transducer to evaluate the gain and bandwidth of the impedance matching networks. The effectiveness of the presented approach is demonstrated through the design, implementation, and characterization of impedance matching networks for a broadband acoustic emission sensor. The impedance matching network improved the power of the acquired signal by 9 times.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singleton, John; Earley, Lawrence M.; Krawczyk, Frank L.
A superluminal antenna element integrates a balun element to better impedance match an input cable or waveguide to a dielectric radiator element, thus preventing stray reflections and consequent undesirable radiation. For example, a dielectric housing material can be used that has a cutout area. A cable can extend into the cutout area. A triangular conductor can function as an impedance transition. An additional cylindrical element functions as a sleeve balun to better impedance match the radiator element to the cable.
Singleton, John; Earley, Lawrence M.; Krawczyk, Frank L.; Potter, James M.; Romero, William P.; Wang, Zhi-Fu
2018-04-17
A superluminal antenna element integrates a balun element to better impedance match an input cable or waveguide to a dielectric radiator element, thus preventing stray reflections and consequent undesirable radiation. For example, a dielectric housing material can be used that has a cutout area. A cable can extend into the cutout area. A triangular conductor can function as an impedance transition. An additional cylindrical element functions as a sleeve balun to better impedance match the radiator element to the cable.
Protection of Renewable-dominated Microgrids: Challenges and Potential Solutions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elkhatib, Mohamed; Ellis, Abraham; Milan Biswal
keywords : Microgrid Protection, Impedance Relay, Signal Processing-based Fault Detec- tion, Networked Microgrids, Communication-Assisted Protection In this report we address the challenge of designing efficient protection system for inverter- dominated microgrids. These microgrids are characterised with limited fault current capacity as a result of current-limiting protection functions of inverters. Typically, inverters limit their fault contribution in sub-cycle time frame to as low as 1.1 per unit. As a result, overcurrent protection could fail completely to detect faults in inverter-dominated microgrids. As part of this project a detailed literature survey of existing and proposed microgrid protection schemes were conducted. The surveymore » concluded that there is a gap in the available microgrid protection methods. The only credible protection solution available in literature for low- fault inverter-dominated microgrids is the differential protection scheme which represents a robust transmission-grade protection solution but at a very high cost. Two non-overcurrent protection schemes were investigated as part of this project; impedance-based protection and transient-based protection. Impedance-based protection depends on monitoring impedance trajectories at feeder relays to detect faults. Two communication-based impedance-based protection schemes were developed. the first scheme utilizes directional elements and pilot signals to locate the fault. The second scheme depends on a Central Protection Unit that communicates with all feeder relays to locate the fault based on directional flags received from feeder relays. The later approach could potentially be adapted to protect networked microgrids and dynamic topology microgrids. Transient-based protection relies on analyzing high frequency transients to detect and locate faults. This approach is very promising but its implementation in the filed faces several challenges. For example, high frequency transients due to faults can be confused with transients due to other events such as capacitor switching. Additionally, while detecting faults by analyzing transients could be doable, locating faults based on analyzing transients is still an open question.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sudhir, Dass; Bandyopadhyay, M., E-mail: mainak@ter-india.org; Chakraborty, A.
2014-01-15
Impedance matching circuit between radio frequency (RF) generator and the plasma load, placed between them, determines the RF power transfer from RF generator to the plasma load. The impedance of plasma load depends on the plasma parameters through skin depth and plasma conductivity or resistivity. Therefore, for long pulse operation of inductively coupled plasmas, particularly for high power (∼100 kW or more) where plasma load condition may vary due to different reasons (e.g., pressure, power, and thermal), online tuning of impedance matching circuit is necessary through feedback. In fusion grade ion source operation, such online methodology through feedback is notmore » present but offline remote tuning by adjusting the matching circuit capacitors and tuning the driving frequency of the RF generator between the ion source operation pulses is envisaged. The present model is an approach for remote impedance tuning methodology for long pulse operation and corresponding online impedance matching algorithm based on RF coil antenna current measurement or coil antenna calorimetric measurement may be useful in this regard.« less
A High Performance Impedance-based Platform for Evaporation Rate Detection.
Chou, Wei-Lung; Lee, Pee-Yew; Chen, Cheng-You; Lin, Yu-Hsin; Lin, Yung-Sheng
2016-10-17
This paper describes the method of a novel impedance-based platform for the detection of the evaporation rate. The model compound hyaluronic acid was employed here for demonstration purposes. Multiple evaporation tests on the model compound as a humectant with various concentrations in solutions were conducted for comparison purposes. A conventional weight loss approach is known as the most straightforward, but time-consuming, measurement technique for evaporation rate detection. Yet, a clear disadvantage is that a large volume of sample is required and multiple sample tests cannot be conducted at the same time. For the first time in literature, an electrical impedance sensing chip is successfully applied to a real-time evaporation investigation in a time sharing, continuous and automatic manner. Moreover, as little as 0.5 ml of test samples is required in this impedance-based apparatus, and a large impedance variation is demonstrated among various dilute solutions. The proposed high-sensitivity and fast-response impedance sensing system is found to outperform a conventional weight loss approach in terms of evaporation rate detection.
NASA Astrophysics Data System (ADS)
Rutkove, S. B.; Darras, B. T.
2013-04-01
Electrical impedance myography (EIM) provides a non-invasive approach for quantifying the severity of neuromuscular disease. Here we determine how well EIM data correlates to functional and ultrasound (US) measures of disease in children with Duchenne muscular dystrophy (DMD) and healthy subjects. Thirteen healthy boys, aged 2-12 years and 14 boys with DMD aged 4-12 years underwent both EIM and US measurements of deltoid, biceps, wrist flexors, quadriceps, tibialis anterior, and medial gastrocnemius. EIM measurements were performed with a custom-designed probe using a commercial multifrequency bioimpedance device. US luminosity data were quantified using a gray-scale analysis approach. Children also underwent the 6-minute walk test, timed tests and strength measurements. EIM and US data were combined across muscles. EIM 50 kHz phase was able to discriminate DMD children from healthy subjects with 98% accuracy. In the DMD patients, average EIM phase measurements also correlated well with standard functional measures. For example the 50 kHz phase correlated with the Northstar Ambulatory Assessment test (R = 0.83, p = 0.02). EIM 50 kHz phase and US correlated as well, with R = -0.79 (p < 0.001). These results show that EIM provides valuable objective measures Duchenne muscular dystrophy severity.
A shape-based quality evaluation and reconstruction method for electrical impedance tomography.
Antink, Christoph Hoog; Pikkemaat, Robert; Malmivuo, Jaakko; Leonhardt, Steffen
2015-06-01
Linear methods of reconstruction play an important role in medical electrical impedance tomography (EIT) and there is a wide variety of algorithms based on several assumptions. With the Graz consensus reconstruction algorithm for EIT (GREIT), a novel linear reconstruction algorithm as well as a standardized framework for evaluating and comparing methods of reconstruction were introduced that found widespread acceptance in the community. In this paper, we propose a two-sided extension of this concept by first introducing a novel method of evaluation. Instead of being based on point-shaped resistivity distributions, we use 2759 pairs of real lung shapes for evaluation that were automatically segmented from human CT data. Necessarily, the figures of merit defined in GREIT were adjusted. Second, a linear method of reconstruction that uses orthonormal eigenimages as training data and a tunable desired point spread function are proposed. Using our novel method of evaluation, this approach is compared to the classical point-shaped approach. Results show that most figures of merit improve with the use of eigenimages as training data. Moreover, the possibility of tuning the reconstruction by modifying the desired point spread function is shown. Finally, the reconstruction of real EIT data shows that higher contrasts and fewer artifacts can be achieved in ventilation- and perfusion-related images.
Two-dimensional vocal tracts with three-dimensional behavior in the numerical generation of vowels.
Arnela, Marc; Guasch, Oriol
2014-01-01
Two-dimensional (2D) numerical simulations of vocal tract acoustics may provide a good balance between the high quality of three-dimensional (3D) finite element approaches and the low computational cost of one-dimensional (1D) techniques. However, 2D models are usually generated by considering the 2D vocal tract as a midsagittal cut of a 3D version, i.e., using the same radius function, wall impedance, glottal flow, and radiation losses as in 3D, which leads to strong discrepancies in the resulting vocal tract transfer functions. In this work, a four step methodology is proposed to match the behavior of 2D simulations with that of 3D vocal tracts with circular cross-sections. First, the 2D vocal tract profile becomes modified to tune the formant locations. Second, the 2D wall impedance is adjusted to fit the formant bandwidths. Third, the 2D glottal flow gets scaled to recover 3D pressure levels. Fourth and last, the 2D radiation model is tuned to match the 3D model following an optimization process. The procedure is tested for vowels /a/, /i/, and /u/ and the obtained results are compared with those of a full 3D simulation, a conventional 2D approach, and a 1D chain matrix model.
NASA Astrophysics Data System (ADS)
Goit, Chandra Shekhar; Saitoh, Masato
2013-03-01
Horizontal impedance functions of inclined single piles are measured experimentally for model soil-pile systems with both the effects of local soil nonlinearity and resonant characteristics. Two practical pile inclinations of 5° and 10° in addition to a vertical pile embedded in cohesionless soil and subjected to lateral harmonic pile head loadings for a wide range of frequencies are considered. Results obtained with low-to-high amplitude of lateral loadings on model soil-pile systems encased in a laminar shear box show that the local nonlinearities have a profound impact on the horizontal impedance functions of piles. Horizontal impedance functions of inclined piles are found to be smaller than the vertical pile and the values decrease as the angle of pile inclination increases. Distinct values of horizontal impedance functions are obtained for the `positive' and `negative' cycles of harmonic loadings, leading to asymmetric force-displacement relationships for the inclined piles. Validation of these experimental results is carried out through three-dimensional nonlinear finite element analyses, and the results from the numerical models are in good agreement with the experimental data. Sensitivity analyses conducted on the numerical models suggest that the consideration of local nonlinearity at the vicinity of the soil-pile interface influence the response of the soil-pile systems.
Stolwijk, Judith A.; Matrougui, Khalid; Renken, Christian W.; Trebak, Mohamed
2014-01-01
The past 20 years have seen significant growth in using impedance-based assays to understand the molecular underpinning of endothelial and epithelial barrier function in response to physiological agonists, pharmacological and toxicological compounds. Most studies on barrier function use G protein coupled receptor (GPCR) agonists which couple to fast and transient changes in barrier properties. The power of impedance based techniques such as Electric Cell-Substrate Impedance Sensing (ECIS) reside in its ability to detect minute changes in cell layer integrity label-free and in real-time ranging from seconds to days. We provide a comprehensive overview of the biophysical principles, applications and recent developments in impedance-based methodologies. Despite extensive application of impedance analysis in endothelial barrier research little attention has been paid to data analysis and critical experimental variables, which are both essential for signal stability and reproducibility. We describe the rationale behind common ECIS data presentation and interpretation and illustrate practical guidelines to improve signal intensity by adapting technical parameters such as electrode layout, monitoring frequency or parameter (resistance versus impedance magnitude). Moreover, we discuss the impact of experimental parameters, including cell source, liquid handling and agonist preparation on signal intensity and kinetics. Our discussions are supported by experimental data obtained from human microvascular endothelial cells challenged with three GPCR agonists, thrombin, histamine and Sphingosine-1-Phosphate. PMID:25537398
Stolwijk, Judith A; Matrougui, Khalid; Renken, Christian W; Trebak, Mohamed
2015-10-01
The past 20 years has seen significant growth in using impedance-based assays to understand the molecular underpinning of endothelial and epithelial barrier function in response to physiological agonists and pharmacological and toxicological compounds. Most studies on barrier function use G protein-coupled receptor (GPCR) agonists which couple to fast and transient changes in barrier properties. The power of impedance-based techniques such as electric cell-substrate impedance sensing (ECIS) resides in its ability to detect minute changes in cell layer integrity label-free and in real-time ranging from seconds to days. We provide a comprehensive overview of the biophysical principles, applications, and recent developments in impedance-based methodologies. Despite extensive application of impedance analysis in endothelial barrier research, little attention has been paid to data analysis and critical experimental variables, which are both essential for signal stability and reproducibility. We describe the rationale behind common ECIS data presentation and interpretation and illustrate practical guidelines to improve signal intensity by adapting technical parameters such as electrode layout, monitoring frequency, or parameter (resistance versus impedance magnitude). Moreover, we discuss the impact of experimental parameters, including cell source, liquid handling, and agonist preparation on signal intensity and kinetics. Our discussions are supported by experimental data obtained from human microvascular endothelial cells challenged with three GPCR agonists, thrombin, histamine, and sphingosine-1-phosphate.
Fluid mechanical model of the Helmholtz resonator
NASA Technical Reports Server (NTRS)
Hersh, A. S.; Walker, B.
1977-01-01
A semi-empirical fluid mechanical model of the acoustic behavior of Helmholtz resonators is presented which predicts impedance as a function of the amplitude and frequency of the incident sound pressure field and resonator geometry. The model assumes that the particle velocity approaches the orifice in a spherical manner. The incident and cavity sound fields are connected by solving the governing oscillating mass and momentum conservation equations. The model is in agreement with the Rayleigh slug-mass model at low values of incident sound pressure level. At high values, resistance is predicted to be independent of frequency, proportional to the square root of the amplitude of the incident sound pressure field, and virtually independent of resonator geometry. Reactance is predicted to depend in a very complicated way upon resonator geometry, incident sound pressure level, and frequency. Nondimensional parameters are defined that divide resonator impedance into three categories corresponding to low, moderately low, and intense incident sound pressure amplitudes. The two-microphone method was used to measure the impedance of a variety of resonators. The data were used to refine and verify the model.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chin, Yong Ho; Chao, Alexander Wu; Blaskiewicz, Michael M.
Effects of the chromaticity on head-tail instabilities for broadband impedances are comprehensively studied, using the two particle model, the Vlasov analysis and computer simulations. We show both in the two particle model and the Vlasov analysis with the trapezoidal (semiconstant) wake model that we can derive universal contour plots for the growth factor as a function of the two dimensionless parameters: the wakefield strength, Υ, and the difference of the betatron phase advances between the head and the tail, χ. They reveal how the chromaticity affects strong head-tail instabilities and excites head-tail instabilities. We also apply the LEP (Large Electron-Positronmore » Collider) broadband resonator model to the Vlasov approach and find that the results are in very good agreement with those of the trapezoidal wake model. The theoretical findings are also reinforced by the simulation results. In conclusion, the trapezoidal wake model turns out to be a very useful tool since it significantly simplifies the time domain analysis and provides well-behaved impedance at the same time.« less
Chin, Yong Ho; Chao, Alexander Wu; Blaskiewicz, Michael M.; ...
2017-07-28
Effects of the chromaticity on head-tail instabilities for broadband impedances are comprehensively studied, using the two particle model, the Vlasov analysis and computer simulations. We show both in the two particle model and the Vlasov analysis with the trapezoidal (semiconstant) wake model that we can derive universal contour plots for the growth factor as a function of the two dimensionless parameters: the wakefield strength, Υ, and the difference of the betatron phase advances between the head and the tail, χ. They reveal how the chromaticity affects strong head-tail instabilities and excites head-tail instabilities. We also apply the LEP (Large Electron-Positronmore » Collider) broadband resonator model to the Vlasov approach and find that the results are in very good agreement with those of the trapezoidal wake model. The theoretical findings are also reinforced by the simulation results. In conclusion, the trapezoidal wake model turns out to be a very useful tool since it significantly simplifies the time domain analysis and provides well-behaved impedance at the same time.« less
NASA Astrophysics Data System (ADS)
Chen, Huaizhen; Pan, Xinpeng; Ji, Yuxin; Zhang, Guangzhi
2017-08-01
A system of aligned vertical fractures and fine horizontal shale layers combine to form equivalent orthorhombic media. Weak anisotropy parameters and fracture weaknesses play an important role in the description of orthorhombic anisotropy (OA). We propose a novel approach of utilizing seismic reflection amplitudes to estimate weak anisotropy parameters and fracture weaknesses from observed seismic data, based on azimuthal elastic impedance (EI). We first propose perturbation in stiffness matrix in terms of weak anisotropy parameters and fracture weaknesses, and using the perturbation and scattering function, we derive PP-wave reflection coefficient and azimuthal EI for the case of an interface separating two OA media. Then we demonstrate an approach to first use a model constrained damped least-squares algorithm to estimate azimuthal EI from partially incidence-phase-angle-stack seismic reflection data at different azimuths, and then extract weak anisotropy parameters and fracture weaknesses from the estimated azimuthal EI using a Bayesian Markov Chain Monte Carlo inversion method. In addition, a new procedure to construct rock physics effective model is presented to estimate weak anisotropy parameters and fracture weaknesses from well log interpretation results (minerals and their volumes, porosity, saturation, fracture density, etc.). Tests on synthetic and real data indicate that unknown parameters including elastic properties (P- and S-wave impedances and density), weak anisotropy parameters and fracture weaknesses can be estimated stably in the case of seismic data containing a moderate noise, and our approach can make a reasonable estimation of anisotropy in a fractured shale reservoir.
NASA Astrophysics Data System (ADS)
Gallasch, Eugen; Kozlovskaya, Inessa
2007-02-01
Long term space flights induce atrophy and contractile changes on postural muscles such effecting tonic motor control. Functional testing of tonic motor control structures is a challenge because of the difficulties to deliver appropriate test forces on crew members. In this paper we propose two approaches for functional testing by using limb attached loading devices. The first approach is based on a frequency and amplitude controllable moving magnet exciter to deliver sinusoidal test forces during limb postures. The responding limb deflection is recorded by an embedded accelerometer to obtain limb impedance. The second approach is based on elastic limb loading to evoke self-excited oscillations during arm extensions. Here the contraction force at the oscillation onset provides information about limb stiffness. The rationale for both testing approaches is based on Feldman's λ-model. An arm expander based on the second approach was probed in a 6-month MIR space flight. The results obtained from the load oscillations, confirmed that this device is well suited to capture space flight induced neuromuscular changes.
Impedance measurement using a two-microphone, random-excitation method
NASA Technical Reports Server (NTRS)
Seybert, A. F.; Parrott, T. L.
1978-01-01
The feasibility of using a two-microphone, random-excitation technique for the measurement of acoustic impedance was studied. Equations were developed, including the effect of mean flow, which show that acoustic impedance is related to the pressure ratio and phase difference between two points in a duct carrying plane waves only. The impedances of a honeycomb ceramic specimen and a Helmholtz resonator were measured and compared with impedances obtained using the conventional standing-wave method. Agreement between the two methods was generally good. A sensitivity analysis was performed to pinpoint possible error sources and recommendations were made for future study. The two-microphone approach evaluated in this study appears to have some advantages over other impedance measuring techniques.
NASA Technical Reports Server (NTRS)
Laskowski, Edward L. (Inventor)
1995-01-01
An apparatus for sensing a target characteristic, such as relative distance between the apparatus and target, target thickness, target material, or lateral position between the apparatus and the target, includes a coil for directing an electro-magnetic field at the target. A voltage controlled oscillator energizes the coil at a resonant frequency which is functionally related to the target characteristic. The coil has an effective impedance value at resonance functionally related to the target characteristic. A frequency monitor measures the resonant frequency. An impedance monitor determines the impedance value when the drive frequency is at the resonant value. A PROM or controller determines the target characteristic in response to the measured resonant frequency and the determined impedance value. The PROM or controller provides a signal responsive to the determined target characteristic.
Thermal behaviors of Ni-MH batteries using a novel impedance spectroscopy
NASA Astrophysics Data System (ADS)
Xiao, Pu; Gao, Wenying; Qiu, Xinping; Zhu, Wentao; Sun, Jie; Chen, Liquan
In this paper, a novel impedance spectroscopy was used to describe the thermal behaviors of Ni-MH batteries. The impedance functions were derived similarly to electric impedance functions. The square of current was treated as a current equivalent and heat-flow as a voltage equivalent. The impedance spectra of batteries during charge showed that the combination of hydrogen and oxygen increased rapidly when charge rate was higher than 0.5 C. Thermal runaway might happen when battery was charged at temperature above 348 K even at a low charge rate. The cycling test showed that the charge efficiency of battery was the highest after cycling at high-rate for 10-100 cycles and decreased after more cycles. Different batteries showed different thermal behaviors which may be caused by the different structures of batteries.
NASA Technical Reports Server (NTRS)
Reid, Margaret A.
1989-01-01
Impedances of fifteen electrodes form each of the four U.S. manufactures were measured at 0.200 V vs. the Hg/HgO reference electrode. This corresponds to a voltage of 1.145 for a Ni/H2 cell. Measurements were also made of a representative sample of these at 0.44 V. At the higher voltage, the impedances were small and very similar, but at the lower voltage there were major differences between manufacturers. Electrodes from the same manufacturers showed only small differences. The impedances of electrodes from two manufacturers were considerably different in 26 percent KOH from those in 31 percent KOH. These preliminary results seen to correlate with the limited data from earlier life testing of cells from these manufacturers. The impedances of cells being tested for Space Station Freedom are being followed, and more impendance measurements of electrodes are being performed as functions of manufacturer, voltage, electrolyte concentration, and cycle history in hopes of finding better correlations of impedance with life.
Nicholls, David P
2018-04-01
The faithful modelling of the propagation of linear waves in a layered, periodic structure is of paramount importance in many branches of the applied sciences. In this paper, we present a novel numerical algorithm for the simulation of such problems which is free of the artificial singularities present in related approaches. We advocate for a surface integral formulation which is phrased in terms of impedance-impedance operators that are immune to the Dirichlet eigenvalues which plague the Dirichlet-Neumann operators that appear in classical formulations. We demonstrate a high-order spectral algorithm to simulate these latter operators based upon a high-order perturbation of surfaces methodology which is rapid, robust and highly accurate. We demonstrate the validity and utility of our approach with a sequence of numerical simulations.
NASA Astrophysics Data System (ADS)
Nicholls, David P.
2018-04-01
The faithful modelling of the propagation of linear waves in a layered, periodic structure is of paramount importance in many branches of the applied sciences. In this paper, we present a novel numerical algorithm for the simulation of such problems which is free of the artificial singularities present in related approaches. We advocate for a surface integral formulation which is phrased in terms of impedance-impedance operators that are immune to the Dirichlet eigenvalues which plague the Dirichlet-Neumann operators that appear in classical formulations. We demonstrate a high-order spectral algorithm to simulate these latter operators based upon a high-order perturbation of surfaces methodology which is rapid, robust and highly accurate. We demonstrate the validity and utility of our approach with a sequence of numerical simulations.
NASA Astrophysics Data System (ADS)
Li, J.; Fogerson, P. M.; Rutkove, S. B.
2010-04-01
Electrical impedance methods can be used to evaluate and monitor neuromuscular disease states. Recently, we have applied tetrapolar surface electrical impedance methods to the gastrocnemius muscle of the rat for this purpose and substantial changes in the impedance parameters after sciatic nerve crush can be identified. In order to be able to study additional animal models of nerve and muscle disease, however, it would highly desirable to be able to perform such impedance measurements in the mouse. Yet the small size of the mouse presents a substantial technical challenge. In this study, we evaluate a basic approach for performing such measurements. A series of thin, stainless steel strip electrodes affixed to the gastrocnemius and interfaced via a separate connector to the Imp SFB7® (Impedimed, Inc), provided an effective means for obtaining impedance data in the 20-500 kHz range. After two weeks, test-retest reproducibility was good, with intra-class correlation coefficients as high 0.84 and variability as low as 12.86 ± 6.18% in the 15 mice studied. Using this approach, it may now be possible to study impedance changes in a variety of mouse models of neuromuscular disease, including amyotrophic lateral sclerosis, spinal muscular atrophy, muscular dystrophy and Charcot-Marie-Tooth disease.
A Practical Approach for Analysis of Input and Output Impedances of Feedback Amplifiers
ERIC Educational Resources Information Center
Abramovitz, A.
2009-01-01
This paper suggests a pedagogical approach to teaching the subject of the analysis of feedback amplifiers for electrical engineering students at the undergraduate level. Special attention is given to derivation of the input and output impedances. In order to make the procedure clear and suitable for classroom presentation an alternative proof of…
Ultra-wideband impedance sensor
McEwan, Thomas E.
1999-01-01
The ultra-wideband impedance sensor (UWBZ sensor, or Z-sensor) is implemented in differential and single-ended configurations. The differential UWBZ sensor employs a sub-nanosecond impulse to determine the balance of an impedance bridge. The bridge is configured as a differential sample-and-hold circuit that has a reference impedance side and an unknown impedance side. The unknown impedance side includes a short transmission line whose impedance is a function of the near proximity of objects. The single-ended UWBZ sensor eliminates the reference side of the bridge and is formed of a sample and hold circuit having a transmission line whose impedance is a function of the near proximity of objects. The sensing range of the transmission line is bounded by the two-way travel time of the impulse, thereby eliminating spurious Doppler modes from large distant objects that would occur in a microwave CW impedance bridge. Thus, the UWBZ sensor is a range-gated proximity sensor. The Z-sensor senses the near proximity of various materials such as metal, plastic, wood, petroleum products, and living tissue. It is much like a capacitance sensor, yet it is impervious to moisture. One broad application area is the general replacement of magnetic sensors, particularly where nonferrous materials need to be sensed. Another broad application area is sensing full/empty levels in tanks, vats and silos, e.g., a full/empty switch in water or petroleum tanks.
Ultra-wideband impedance sensor
McEwan, T.E.
1999-03-16
The ultra-wideband impedance sensor (UWBZ sensor, or Z-sensor) is implemented in differential and single-ended configurations. The differential UWBZ sensor employs a sub-nanosecond impulse to determine the balance of an impedance bridge. The bridge is configured as a differential sample-and-hold circuit that has a reference impedance side and an unknown impedance side. The unknown impedance side includes a short transmission line whose impedance is a function of the near proximity of objects. The single-ended UWBZ sensor eliminates the reference side of the bridge and is formed of a sample and hold circuit having a transmission line whose impedance is a function of the near proximity of objects. The sensing range of the transmission line is bounded by the two-way travel time of the impulse, thereby eliminating spurious Doppler modes from large distant objects that would occur in a microwave CW impedance bridge. Thus, the UWBZ sensor is a range-gated proximity sensor. The Z-sensor senses the near proximity of various materials such as metal, plastic, wood, petroleum products, and living tissue. It is much like a capacitance sensor, yet it is impervious to moisture. One broad application area is the general replacement of magnetic sensors, particularly where nonferrous materials need to be sensed. Another broad application area is sensing full/empty levels in tanks, vats and silos, e.g., a full/empty switch in water or petroleum tanks. 2 figs.
NASA Astrophysics Data System (ADS)
Aleksanyan, Grayr; Shcherbakov, Ivan; Kucher, Artem; Sulyz, Andrew
2018-04-01
With continuous monitoring of the lungs using multi-angle electric impedance tomography method, a large array of images of impedance changes in the patient's chest cavity is accumulated. This article proposes a method for evaluating the regional ventilation function of lungs based on the results of continuous monitoring using the multi-angle electric impedance tomography method, which allows one image of the thoracic cavity to be formed on the basis of a large array of images of the impedance change in the patient's chest cavity. In the presence of pathologies in the lungs (neoplasms, fluid, pneumothorax, etc.) in these areas, air filling will be disrupted, which will be displayed on the generated image. When conducting continuous monitoring in several sections, a three-dimensional pattern of air filling of the thoracic cavity is possible.
Scattering by a groove in an impedance plane
NASA Technical Reports Server (NTRS)
Bindiganavale, Sunil; Volakis, John L.
1993-01-01
An analysis of two-dimensional scattering from a narrow groove in an impedance plane is presented. The groove is represented by a impedance surface and the problem reduces to that of scattering from an impedance strip in an otherwise uniform impedance plane. On the basis of this model, appropriate integral equations are constructed using a form of the impedance plane Green's functions involving rapidly convergent integrals. The integral equations are solved by introducing a single basis representation of the equivalent current on the narrow impedance insert. Both transverse electric (TE) and transverse magnetic (TM) polarizations are treated. The resulting solution is validated by comparison with results from the standard boundary integral method (BIM) and a high frequency solution. It is found that the presented solution for narrow impedance inserts can be used in conjunction with the high frequency solution for the characterization of impedance inserts of any given width.
Takmakov, Pavel; Ruda, Kiersten; Phillips, K Scott; Isayeva, Irada S; Krauthamer, Victor; Welle, Cristin G
2017-01-01
Objective A challenge for implementing high bandwidth cortical brain–machine interface devices in patients is the limited functional lifespan of implanted recording electrodes. Development of implant technology currently requires extensive non-clinical testing to demonstrate device performance. However, testing the durability of the implants in vivo is time-consuming and expensive. Validated in vitro methodologies may reduce the need for extensive testing in animal models. Approach Here we describe an in vitro platform for rapid evaluation of implant stability. We designed a reactive accelerated aging (RAA) protocol that employs elevated temperature and reactive oxygen species (ROS) to create a harsh aging environment. Commercially available microelectrode arrays (MEAs) were placed in a solution of hydrogen peroxide at 87 °C for a period of 7 days. We monitored changes to the implants with scanning electron microscopy and broad spectrum electrochemical impedance spectroscopy (1 Hz–1 MHz) and correlated the physical changes with impedance data to identify markers associated with implant failure. Main results RAA produced a diverse range of effects on the structural integrity and electrochemical properties of electrodes. Temperature and ROS appeared to have different effects on structural elements, with increased temperature causing insulation loss from the electrode microwires, and ROS concentration correlating with tungsten metal dissolution. All array types experienced impedance declines, consistent with published literature showing chronic (>30 days) declines in array impedance in vivo. Impedance change was greatest at frequencies <10 Hz, and smallest at frequencies 1 kHz and above. Though electrode performance is traditionally characterized by impedance at 1 kHz, our results indicate that an impedance change at 1 kHz is not a reliable predictive marker of implant degradation or failure. Significance ROS, which are known to be present in vivo, can create structural damage and change electrical properties of MEAs. Broad-spectrum electrical impedance spectroscopy demonstrates increased sensitivity to electrode damage compared with single-frequency measurements. RAA can be a useful tool to simulate worst-case in vivo damage resulting from chronic electrode implantation, simplifying the device development lifecycle. PMID:25627426
Method to tune electrical impedance of LSMO/PMN-PT by nanocontact
NASA Astrophysics Data System (ADS)
Zhou, Hao; Pei, Yongmao; Wang, Yaobing; Lei, Hongshuai
2018-01-01
Electromagnetic composites have wide application in the functional devices. For the best performance of devices, the regulation of the electrical impedance has been being desired for the impedance matching in service. However, the keeping of impedance matching in service is quite challenging. In the present work, a mechanical method for tuning the electrical impedance of La0.7Sr0.3MnO3/0.72Pb(Mg1/3Nb2/3)O3-0.28PbTiO3 (LSMO/PMN-PT) based on the nanocontact technique is proposed. It is found that the electrical impedance reduces with the increase of the nanocontact load. A linear relationship is found between the square of impedance magnitude and the inverse of nanocontact depth. Furthermore, a method for predicting the contact-depth-dependent impedance magnitude of LSMO/PMN-PT is proposed.
Estimating an Impedance-to-Flow Parameter for Flood Peak Prediction in Semi-Arid Watersheds 1997
USDA-ARS?s Scientific Manuscript database
The time of concentration equation used in Pima County, Arizona, includes a hydrologic parameter representing the impedance to flow for peak discharge estimation on small (<10 mi2) semiarid watersheds. The impedance-to-flow parameter is similar in function to the hydraulic Manning’s n roughness coef...
Wang, Lucy L; Ahad, Mohammad; McEwan, Alistair; Li, Jia; Jafarpoor, Mina; Rutkove, Seward B
2011-06-01
The surface measurement of electrical impedance of muscle, incorporated as the technique of electrical impedance myography (EIM), provides a noninvasive approach for evaluating neuromuscular diseases, including amyotrophic lateral sclerosis. However, the relationship between alterations in surface impedance and the electrical properties of muscle remains uncertain. In order to investigate this further, a group of healthy adult rats, a group of rats two weeks postsciatic crush, and a group of animals six months postcrush underwent EIM of the gastrocnemius-soleus complex. The animals were then killed and the conductivity and permittivity of the extracted muscle measured. Finite-element models based on MRI data were then constructed for each group. The characteristic EIM parameter, 50 kHz phase (±standard error), obtained with surface impedance measurements was 17.3° ± 0.3° for normal animals, 13.8° ± 0.7° for acutely injured animals, and 16.1° ± 0.5° for chronically injured animals. The models predicted parallel changes with phase values of 24.3°, 18.8°, and 21.2° for the normal, acute, and chronic groups, respectively. Other multifrequency impedance parameters showed similar alterations. These results confirm that surface impedance measurements taken in conjunction with anatomical data and finite-element models may offer a noninvasive approach for assessing biophysical alterations in muscle in neuromuscular disease states.
Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators.
Kim, Pil-Jong; Kim, Hong-Gee; Cho, Byeong-Hoon
2015-05-01
The aim of this paper was evaluating the ratios of electrical impedance measurements reported in previous studies through a correlation analysis in order to explicit it as the contributing factor to the accuracy of electronic apex locator (EAL). The literature regarding electrical property measurements of EALs was screened using Medline and Embase. All data acquired were plotted to identify correlations between impedance and log-scaled frequency. The accuracy of the impedance ratio method used to detect the apical constriction (APC) in most EALs was evaluated using linear ramp function fitting. Changes of impedance ratios for various frequencies were evaluated for a variety of file positions. Among the ten papers selected in the search process, the first-order equations between log-scaled frequency and impedance were in the negative direction. When the model for the ratios was assumed to be a linear ramp function, the ratio values decreased if the file went deeper and the average ratio values of the left and right horizontal zones were significantly different in 8 out of 9 studies. The APC was located within the interval of linear relation between the left and right horizontal zones of the linear ramp model. Using the ratio method, the APC was located within a linear interval. Therefore, using the impedance ratio between electrical impedance measurements at different frequencies was a robust method for detection of the APC.
Zong, Xianli; Zhu, Rong; Guo, Xiaoliang
2015-01-01
In this paper, a fine gold nanostructure synthesized on selective planar microelectrodes in micro-chip is realized by using an advanced hybrid fabrication approach incorporating growth of nanorods (NRs) with gold electroplating. By this developed nanostructure, integration of in-situ surface-enhanced Raman spectroscopy (SERS) detection with electrochemical impedance spectroscopy (EIS) measurement for label-free, nondestructive, real-time and rapid monitoring on a single cell has been achieved. Moreover, parameters of Au nanostructures such as size of nanoholes/nanogaps can be controllably adjusted in the fabrication. We have demonstrated a SERS enhancement factor of up to ~2.24 × 106 and double-layer impedance decrease ratio of 90% ~ 95% at low frequency range below 200 kHz by using nanostructured microelectrodes. SERS detection and in-situ EIS measurement of a trapped single cell by using planar microelectrodes are realized to demonstrate the compatibility, multi-functions, high-sensitivity and simplicity of the micro-chip system. This dual function platform integrating SERS and EIS is of great significance in biological, biochemical and biomedical applications. PMID:26558325
Deurenberg, P; Andreoli, A; de Lorenzo, A
1996-01-01
Total body water and extracellular water were measured by deuterium oxide and bromide dilution respectively in 23 healthy males and 25 healthy females. In addition, total body impedance was measured at 17 frequencies, ranging from 1 kHz to 1350 kHz. Modelling programs were used to extrapolate impedance values to frequency zero (extracellular resistance) and frequency infinity (total body water resistance). Impedance indexes (height2/Zf) were computed at all 17 frequencies. The estimation errors of extracellular resistance and total body water resistance were 1% and 3%, respectively. Impedance and impedance index at low frequency were correlated with extracellular water, independent of the amount of total body water. Total body water showed the greatest correlation with impedance and impedance index at high frequencies. Extrapolated impedance values did not show a higher correlation compared to measured values. Prediction formulas from the literature applied to fixed frequencies showed the best mean and individual predictions for both extracellular water and total body water. It is concluded that, at least in healthy individuals with normal body water distribution, modelling impedance data has no advantage over impedance values measured at fixed frequencies, probably due to estimation errors in the modelled data.
Ultra-low output impedance RF power amplifier for parallel excitation.
Chu, Xu; Yang, Xing; Liu, Yunfeng; Sabate, Juan; Zhu, Yudong
2009-04-01
Inductive coupling between coil elements of a transmit array is one of the key challenges faced by parallel RF transmission. An ultra-low output impedance RF power amplifier (PA) concept was introduced to address this challenge. In an example implementation, an output-matching network was designed to transform the drain-source impedance of the metallic oxide semiconductor field effect transistor (MOSFET) into a very low value for suppressing interelement coupling effect, and meanwhile, to match the input impedance of the coil to the optimum load of the MOSFET for maximizing the available output power. Two prototype amplifiers with 500-W output rating were developed accordingly, and were further evaluated with a transmit array in phantom experiments. Compared to the conventional 50-Omega sources, the new approach exhibited considerable effectiveness suppressing the effects of interelement coupling. The experiments further indicated that the isolation performance was comparable to that achieved by optimized overlap decoupling. The new approach, benefiting from a distinctive current-source characteristic, also exhibited a superior robustness against load variation. Feasibility of the new approach in high-field MR was demonstrated on a 3T clinical scanner.
NASA Technical Reports Server (NTRS)
Hambric, Stephen A.; Hanford, Amanda D.; Shepherd, Micah R.; Campbell, Robert L.; Smith, Edward C.
2010-01-01
A computational approach for simulating the effects of rolling element and journal bearings on the vibration and sound transmission through gearboxes has been demonstrated. The approach, using ARL/Penn State s CHAMP methodology, uses Component Mode Synthesis of housing and shafting modes computed using Finite Element (FE) models to allow for rapid adjustment of bearing impedances in gearbox models. The approach has been demonstrated on NASA GRC s test gearbox with three different bearing configurations: in the first condition, traditional rolling element (ball and roller) bearings were installed, and in the second and third conditions, the traditional bearings were replaced with journal and wave bearings (wave bearings are journal bearings with a multi-lobed wave pattern on the bearing surface). A methodology for computing the stiffnesses and damping in journal and wave bearings has been presented, and demonstrated for the journal and wave bearings used in the NASA GRC test gearbox. The FE model of the gearbox, along with the rolling element bearing coupling impedances, was analyzed to compute dynamic transfer functions between forces applied to the meshing gears and accelerations on the gearbox housing, including several locations near the bearings. A Boundary Element (BE) acoustic model was used to compute the sound radiated by the gearbox. Measurements of the Gear Mesh Frequency (GMF) tones were made by NASA GRC at several operational speeds for the rolling element and journal bearing gearbox configurations. Both the measurements and the CHAMP numerical model indicate that the journal bearings reduce vibration and noise for the second harmonic of the gear meshing tones, but show no clear benefit to using journal bearings to reduce the amplitudes of the fundamental gear meshing tones. Also, the numerical model shows that the gearbox vibrations and radiated sound are similar for journal and wave bearing configurations.
The general 2-D moments via integral transform method for acoustic radiation and scattering
NASA Astrophysics Data System (ADS)
Smith, Jerry R.; Mirotznik, Mark S.
2004-05-01
The moments via integral transform method (MITM) is a technique to analytically reduce the 2-D method of moments (MoM) impedance double integrals into single integrals. By using a special integral representation of the Green's function, the impedance integral can be analytically simplified to a single integral in terms of transformed shape and weight functions. The reduced expression requires fewer computations and reduces the fill times of the MoM impedance matrix. Furthermore, the resulting integral is analytic for nearly arbitrary shape and weight function sets. The MITM technique is developed for mixed boundary conditions and predictions with basic shape and weight function sets are presented. Comparisons of accuracy and speed between MITM and brute force are presented. [Work sponsored by ONR and NSWCCD ILIR Board.
Quantum optics in a high impedance environment
NASA Astrophysics Data System (ADS)
Puertas, Javier; Gheeraert, Nicolas; Krupko, Yuriy; Dassonneville, Remy; Planat, Luca; Foroughui, Farshad; Naud, Cecile; Guichard, Wiebke; Buisson, Olivier; Florens, Serge; Roch, Nicolas; Snyman, Izak
Understanding light matter interaction remains a key topic in fundamental physics. Its strength is imposed by the fine structure constant, α. For most atomic and molecular systems α =e2/ℏc 4 πɛo = 1 / 137 << 1 , giving weak interactions. When dealing with superconducting artificial atoms, α is either proportional to 1 /Zc (magnetic coupling) or Zc (electric coupling), where Zc is the characteristic impedance of the environment. Recent experiments followed the first approach, coupling a flux qubit to a low impedance environment, demonstrating strong interaction (α 1). In our work, we reached the large α regime, following a complementary approach: we couple electrically a transmon qubit to an array of 5000 SQUIDs. This metamaterial provides high characteristic impedance ( 3 kΩ), in-situ flux tunability and full control over its dispersion relation. In this new regime, all usual approximations break down and new phenomena such as frequency conversion at the single photon level are expected.
Improving Outcomes of Behavioral Intervention Plans
ERIC Educational Resources Information Center
Walker, Jennifer D.; Barry, Colleen
2017-01-01
According to federal mandates, if a student's behavior impedes their learning or the learning of others, the individualized education program team is required to address this with a functional behavioral assessment (FBA). The intent of the FBA is to determine the function, or reason, of the impeding behavior for the development of a behavioral…
An investigation of soil-structure interaction effects observed at the MIT Green Building
Taciroglu, Ertugrul; Çelebi, Mehmet; Ghahari, S. Farid; Abazarsa, Fariba
2016-01-01
The soil-foundation impedance function of the MIT Green Building is identified from its response signals recorded during an earthquake. Estimation of foundation impedance functions from seismic response signals is a challenging task, because: (1) the foundation input motions (FIMs) are not directly measurable, (2) the as-built properties of the super-structure are only approximately known, and (3) the soil-foundation impedance functions are inherently frequency-dependent. In the present study, aforementioned difficulties are circumvented by using, in succession, a blind modal identification (BMID) method, a simplified Timoshenko beam model (TBM), and a parametric updating of transfer functions (TFs). First, the flexible-base modal properties of the building are identified from response signals using the BMID method. Then, a flexible-base TBM is updated using the identified modal data. Finally, the frequency-dependent soil-foundation impedance function is estimated by minimizing the discrepancy between TFs (of pairs instrumented floors) that are (1) obtained experimentally from earthquake data and (2) analytically from the updated TBM. Using the fully identified flexible-base TBM, the FIMs as well as building responses at locations without instruments can be predicted, as demonstrated in the present study.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Passos de Figueiredo, Leandro, E-mail: leandrop.fgr@gmail.com; Grana, Dario; Santos, Marcio
We propose a Bayesian approach for seismic inversion to estimate acoustic impedance, porosity and lithofacies within the reservoir conditioned to post-stack seismic and well data. The link between elastic and petrophysical properties is given by a joint prior distribution for the logarithm of impedance and porosity, based on a rock-physics model. The well conditioning is performed through a background model obtained by well log interpolation. Two different approaches are presented: in the first approach, the prior is defined by a single Gaussian distribution, whereas in the second approach it is defined by a Gaussian mixture to represent the well datamore » multimodal distribution and link the Gaussian components to different geological lithofacies. The forward model is based on a linearized convolutional model. For the single Gaussian case, we obtain an analytical expression for the posterior distribution, resulting in a fast algorithm to compute the solution of the inverse problem, i.e. the posterior distribution of acoustic impedance and porosity as well as the facies probability given the observed data. For the Gaussian mixture prior, it is not possible to obtain the distributions analytically, hence we propose a Gibbs algorithm to perform the posterior sampling and obtain several reservoir model realizations, allowing an uncertainty analysis of the estimated properties and lithofacies. Both methodologies are applied to a real seismic dataset with three wells to obtain 3D models of acoustic impedance, porosity and lithofacies. The methodologies are validated through a blind well test and compared to a standard Bayesian inversion approach. Using the probability of the reservoir lithofacies, we also compute a 3D isosurface probability model of the main oil reservoir in the studied field.« less
Transition metal oxide as anode interface buffer for impedance spectroscopy
NASA Astrophysics Data System (ADS)
Xu, Hui; Tang, Chao; Wang, Xu-Liang; Zhai, Wen-Juan; Liu, Rui-Lan; Rong, Zhou; Pang, Zong-Qiang; Jiang, Bing; Fan, Qu-Li; Huang, Wei
2015-12-01
Impedance spectroscopy is a strong method in electric measurement, which also shows powerful function in research of carrier dynamics in organic semiconductors when suitable mathematical physical models are used. Apart from this, another requirement is that the contact interface between the electrode and materials should at least be quasi-ohmic contact. So in this report, three different transitional metal oxides, V2O5, MoO3 and WO3 were used as hole injection buffer for interface of ITO/NPB. Through the impedance spectroscopy and PSO algorithm, the carrier mobilities and I-V characteristics of the NPB in different devices were measured. Then the data curves were compared with the single layer device without the interface layer in order to investigate the influence of transitional metal oxides on the carrier mobility. The careful research showed that when the work function (WF) of the buffer material was just between the work function of anode and the HOMO of the organic material, such interface material could work as a good bridge for carrier injection. Under such condition, the carrier mobility measured through impedance spectroscopy should be close to the intrinsic value. Considering that the HOMO (or LUMO) of most organic semiconductors did not match with the work function of the electrode, this report also provides a method for wide application of impedance spectroscopy to the research of carrier dynamics.
Statistically Based Approach to Broadband Liner Design and Assessment
NASA Technical Reports Server (NTRS)
Jones, Michael G. (Inventor); Nark, Douglas M. (Inventor)
2016-01-01
A broadband liner design optimization includes utilizing in-duct attenuation predictions with a statistical fan source model to obtain optimum impedance spectra over a number of flow conditions for one or more liner locations in a bypass duct. The predicted optimum impedance information is then used with acoustic liner modeling tools to design liners having impedance spectra that most closely match the predicted optimum values. Design selection is based on an acceptance criterion that provides the ability to apply increasing weighting to specific frequencies and/or operating conditions. One or more broadband design approaches are utilized to produce a broadband liner that targets a full range of frequencies and operating conditions.
Electrical impedance spectroscopy of neutron-irradiated nanocrystalline silicon carbide (3C-SiC)
NASA Astrophysics Data System (ADS)
Huseynov, Elchin M.
2018-01-01
It the present work, impedance spectra of nanocrystalline 3C-SiC particles have been comparatively analyzed before and after neutron irradiation. Resonance states and shifts were observed at the impedance spectra of nanocrystalline 3C-SiC particles after neutron irradiation. Relaxation time has been calculated from interdependence of real and imaginary parts of impedance of nanocrystalline 3C-SiC particles. Calculated relaxation times have been investigated as a function of neutron irradiation period. Neutron transmutation (31P isotopes production) effects on the impedance spectra and relaxation times have been studied. Moreover, influence of agglomeration and amorphous transformation to the impedance spectra and relaxation times of nanocrystalline 3C-SiC particles have been investigated.
Characterizing fiber-reinforced composite structures using AC-impedance spectroscopy (AC-IS)
NASA Astrophysics Data System (ADS)
Woo, Leta Y.
Property enhancement in composites depends largely on the reinforcement. For fiber-reinforced composites, the distribution of fibers is crucial in determining the electrical and mechanical performance. Image analysis methods for characterization can be time-consuming and/or destructive. This work explores the capability of AC-impedance spectroscopy (AC-IS), an electrical measurement technique, to serve as a rapid, non-destructive tool for characterizing composite microstructure. The composite requirements include a filler that is electrically conducting or semi-conducting with higher conductivity than the matrix, and a high-impedance interface or coating between the filler and the matrix. To establish an AC-IS characterization method, cement-matrix composites with steel reinforcement were employed as both a technologically important and a model system to investigate how fibers affect the electrical response. Beginning with spherical particulates and then fibers, composites were examined using composite theory and an "intrinsic conductivity" approach. The intrinsic conductivity approach applies to composites with low volume fractions of fibers (i.e., in the dilute regime) and relates how the composite conductivity varies relative to the matrix as a function of volume fraction. A universal equivalent circuit model was created to understand the AC-IS response of composites based on the geometry and volume fraction of the filler. Deviation from predicted behavior was assessed using a developed f-function, which quantifies how fibers contribute to the overall electrical response of the composite. Using the f-function, an AC-IS method for investigating fiber dispersion was established to characterize alignment, settling/segregation, and aggregation. Alignment was investigated using measurements made in three directions. A point-probe technique characterized settling and/or large-scale inhomogeneous mixing in samples. Aggregation was quantified using a "dispersion factor" that compared theoretical with measured values and served as an upper limit for how well the fibers were dispersed. The AC-IS method was then extended to two different cement-matrix composite systems, low resistivity fresh-paste cement composites (confirmed by time domain reflectometry) and high resistivity cement composites, both of which required additional analysis to apply the AC-IS characterization method.
Alvarez, P. E.; Vallejo, A. E.
2008-01-01
Kinetics of facilitated ion transport through planar bilayer membranes are normally analyzed by electrical conductance methods. The additional use of electrical relaxation techniques, such as voltage jump, is necessary to evaluate individual rate constants. Although electrochemical impedance spectroscopy is recognized as the most powerful of the available electric relaxation techniques, it has rarely been used in connection with these kinetic studies. According to the new approach presented in this work, three steps were followed. First, a kinetic model was proposed that has the distinct quality of being general, i.e., it properly describes both carrier and channel mechanisms of ion transport. Second, the state equations for steady-state and for impedance experiments were derived, exhibiting the input–output representation pertaining to the model’s structure. With the application of a method based on the similarity transformation approach, it was possible to check that the proposed mechanism is distinguishable, i.e., no other model with a different structure exhibits the same input–output behavior for any input as the original. Additionally, the method allowed us to check whether the proposed model is globally identifiable (i.e., whether there is a single set of fit parameters for the model) when analyzed in terms of its impedance response. Thus, our model does not represent a theoretical interpretation of the experimental impedance but rather constitutes the prerequisite to select this type of experiment in order to obtain optimal kinetic identification of the system. Finally, impedance measurements were performed and the results were fitted to the proposed theoretical model in order to obtain the kinetic parameters of the system. The successful application of this approach is exemplified with results obtained for valinomycin–K+ in lipid bilayers supported onto gold substrates, i.e., an arrangement capable of emulating biological membranes. PMID:19669528
Whole-body impedance--what does it measure?
Foster, K R; Lukaski, H C
1996-09-01
Although the bioelectrical impedance technique is widely used in human nutrition and clinical research, an integrated summary of the biophysical and bioelectrical bases of this approach is lacking. We summarize the pertinent electrical phenomena relevant to the application of the impedance technique in vivo and discuss the relations between electrical measurements and biological conductor volumes. Key terms in the derivation of bioelectrical impedance analysis are described and the relation between the electrical properties of tissues and tissue structure is discussed. The relation between the impedance of an object and its geometry, scale, and intrinsic electrical properties is also discussed. Correlations between whole-body impedance measurements and various bioconductor volumes, such as total body water and fat-free mass, are experimentally well established; however, the reason for the success of the impedence technique is much less clear. The bioengineering basis for the technique is critically presented and considerations are proposed that might help to clarify the method and potentially improve its sensitivity.
Design and construction of the artificial patient module for testing bioimpedance measuring devices
NASA Astrophysics Data System (ADS)
Młyńczak, Marcel; Pariaszewska, Katarzyna; Niewiadomski, Wiktor; Cybulski, Gerard
2013-10-01
The purpose of this study was to describe the design of the electronic module for testing bioimpedance measuring devices, for example impedance cardiographs or impedance pneumographs. Artificial Patient was conceived as an electronic equivalent of the impedance of skin-electrode interface and the impedance between electrodes - measured one. Different approaches in imitating a resistance of skin and an impedance of electrode-skin connection were presented. The module was adapted for frequently applied tetrapolar electrode configuration. Therefore the design do not enclose the elements simulating impedance between skin and receiver electrodes due to negligible effect of this impedance on the current flow through the receiver. The Artificial Patient enables testing either application generators, or receiver parts, particularly the level of noise and distortions of the signal. Use of digitally controlled potentiometer allows simulating different tissue resistances changes such as constant values, very-low-frequency and low-frequency changes corresponding to those caused by breathing or heart activity. Also it allows distorting signals in order to test algorithms of artifacts attenuation.
Evaluation of a cost-effective loads approach. [for Viking Orbiter light weight structural design
NASA Technical Reports Server (NTRS)
Garba, J. A.; Wada, B. K.; Bamford, R.; Trubert, M. R.
1976-01-01
A shock spectra/impedance method for loads prediction is used to estimate member loads for the Viking Orbiter, a 7800-lb interplanetary spacecraft that has been designed using transient loads analysis techniques. The transient loads analysis approach leads to a lightweight structure but requires complex and costly analyses. To reduce complexity and cost a shock spectra/impedance method is currently being used to design the Mariner Jupiter Saturn spacecraft. This method has the advantage of using low-cost in-house loads analysis techniques and typically results in more conservative structural loads. The method is evaluated by comparing the increase in Viking member loads to the loads obtained by the transient loads analysis approach. An estimate of the weight penalty incurred by using this method is presented. The paper also compares the calculated flight loads from the transient loads analyses and the shock spectra/impedance method to measured flight data.
Protection of Renewable-dominated Microgrids: Challenges and Potential Solutions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elkhatib, Mohamed; Ellis, Abraham; Biswal, Milan
In this report we address the challenge of designing efficient protection system for inverter- dominated microgrids. These microgrids are characterised with limited fault current capacity as a result of current-limiting protection functions of inverters. Typically, inverters limit their fault contribution in sub-cycle time frame to as low as 1.1 per unit. As a result, overcurrent protection could fail completely to detect faults in inverter-dominated microgrids. As part of this project a detailed literature survey of existing and proposed microgrid protection schemes were conducted. The survey concluded that there is a gap in the available microgrid protection methods. The only crediblemore » protection solution available in literature for low- fault inverter-dominated microgrids is the differential protection scheme which represents a robust transmission-grade protection solution but at a very high cost. Two non-overcurrent protection schemes were investigated as part of this project; impedance-based protection and transient-based protection. Impedance-based protection depends on monitoring impedance trajectories at feeder relays to detect faults. Two communication-based impedance-based protection schemes were developed. the first scheme utilizes directional elements and pilot signals to locate the fault. The second scheme depends on a Central Protection Unit that communicates with all feeder relays to locate the fault based on directional flags received from feeder relays. The later approach could potentially be adapted to protect networked microgrids and dynamic topology microgrids. Transient-based protection relies on analyzing high frequency transients to detect and locate faults. This approach is very promising but its implementation in the filed faces several challenges. For example, high frequency transients due to faults can be confused with transients due to other events such as capacitor switching. Additionally, while detecting faults by analyzing transients could be doable, locating faults based on analyzing transients is still an open question.« less
Phase division multiplexed EIT for enhanced temporal resolution.
Dowrick, T; Holder, D
2018-03-29
The most commonly used EIT paradigm (time division multiplexing) limits the temporal resolution of impedance images due to the need to switch between injection electrodes. Advances have previously been made using frequency division multiplexing (FDM) to increase temporal resolution, but in cases where a fixed range of frequencies is available, such as imaging fast neural activity, an upper limit is placed on the total number of simultaneous injections. The use of phase division multiplexing (PDM) where multiple out of phase signals can be injected at each frequency is investigated to increase temporal resolution. TDM, FDM and PDM were compared in head tank experiments, to compare transfer impedance measurements and spatial resolution between the three techniques. A resistor phantom paradigm was established to investigate the imaging of one-off impedance changes, of magnitude 1% and with durations as low as 500 µs (similar to those seen in nerve bundles), using both PDM and TDM approaches. In head tank experiments, a strong correlation (r > 0.85 and p < 0.001) was present between the three sets of measured transfer impedances, and no statistically significant difference was found in reconstructed image quality. PDM was able to image impedance changes down to 500 µs in the phantom experiments, while the minimum duration imaged using TDM was 5 ms. PDM offers a possible solution to the imaging of fast moving impedance changes (such as in nerves), where the use of triggering or coherent averaging is not possible. The temporal resolution presents an order of magnitude improvement of the TDM approach, and the approach addresses the limited spatial resolution of FDM by increasing the number of simultaneous EIT injections.
Acoustic Impedance Inversion of Seismic Data Using Genetic Algorithm
NASA Astrophysics Data System (ADS)
Eladj, Said; Djarfour, Noureddine; Ferahtia, Djalal; Ouadfeul, Sid-Ali
2013-04-01
The inversion of seismic data can be used to constrain estimates of the Earth's acoustic impedance structure. This kind of problem is usually known to be non-linear, high-dimensional, with a complex search space which may be riddled with many local minima, and results in irregular objective functions. We investigate here the performance and the application of a genetic algorithm, in the inversion of seismic data. The proposed algorithm has the advantage of being easily implemented without getting stuck in local minima. The effects of population size, Elitism strategy, uniform cross-over and lower mutation are examined. The optimum solution parameters and performance were decided as a function of the testing error convergence with respect to the generation number. To calculate the fitness function, we used L2 norm of the sample-to-sample difference between the reference and the inverted trace. The cross-over probability is of 0.9-0.95 and mutation has been tested at 0.01 probability. The application of such a genetic algorithm to synthetic data shows that the inverted acoustic impedance section was efficient. Keywords: Seismic, Inversion, acoustic impedance, genetic algorithm, fitness functions, cross-over, mutation.
NASA Astrophysics Data System (ADS)
Snakowska, Anna; Jurkiewicz, Jerzy; Gorazd, Łukasz
2017-05-01
The paper presents derivation of the impedance matrix based on the rigorous solution of the wave equation obtained by the Wiener-Hopf technique for a semi-infinite unflanged cylindrical duct. The impedance matrix allows, in turn, calculate the acoustic impedance along the duct and, as a special case, the radiation impedance. The analysis is carried out for a multimode incident wave accounting for modes coupling on the duct outlet not only qualitatively but also quantitatively for a selected source operating inside. The quantitative evaluation of the acoustic impedance requires setting of modes amplitudes which has been obtained applying the mode decomposition method to the far-field pressure radiation measurements and theoretical formulae for single mode directivity characteristics for an unflanged duct. Calculation of the acoustic impedance for a non-uniform distribution of the sound pressure and the sound velocity on a duct cross section requires determination of the acoustic power transmitted along/radiated from a duct. In the paper, the impedance matrix, the power, and the acoustic impedance were derived as functions of Helmholtz number and distance from the outlet.
The use of the Kalman filter in the automated segmentation of EIT lung images.
Zifan, A; Liatsis, P; Chapman, B E
2013-06-01
In this paper, we present a new pipeline for the fast and accurate segmentation of impedance images of the lungs using electrical impedance tomography (EIT). EIT is an emerging, promising, non-invasive imaging modality that produces real-time, low spatial but high temporal resolution images of impedance inside a body. Recovering impedance itself constitutes a nonlinear ill-posed inverse problem, therefore the problem is usually linearized, which produces impedance-change images, rather than static impedance ones. Such images are highly blurry and fuzzy along object boundaries. We provide a mathematical reasoning behind the high suitability of the Kalman filter when it comes to segmenting and tracking conductivity changes in EIT lung images. Next, we use a two-fold approach to tackle the segmentation problem. First, we construct a global lung shape to restrict the search region of the Kalman filter. Next, we proceed with augmenting the Kalman filter by incorporating an adaptive foreground detection system to provide the boundary contours for the Kalman filter to carry out the tracking of the conductivity changes as the lungs undergo deformation in a respiratory cycle. The proposed method has been validated by using performance statistics such as misclassified area, and false positive rate, and compared to previous approaches. The results show that the proposed automated method can be a fast and reliable segmentation tool for EIT imaging.
Ehrensberger, Mark T; Gilbert, Jeremy L
2010-05-01
The measurement of electrochemical impedance is a valuable tool to assess the electrochemical environment that exists at the surface of metallic biomaterials. This article describes the development and validation of a new technique, potential step impedance analysis (PSIA), to assess the electrochemical impedance of materials whose interface with solution can be modeled as a simplified Randles circuit that is modified with a constant phase element. PSIA is based upon applying a step change in voltage to a working electrode and analyzing the subsequent current transient response in a combined time and frequency domain technique. The solution resistance, polarization resistance, and interfacial capacitance are found directly in the time domain. The experimental current transient is numerically transformed to the frequency domain to determine the constant phase exponent, alpha. This combined time and frequency approach was tested using current transients generated from computer simulations, from resistor-capacitor breadboard circuits, and from commercially pure titanium samples immersed in phosphate buffered saline and polarized at -800 mV or +1000 mV versus Ag/AgCl. It was shown that PSIA calculates equivalent admittance and impedance behavior over this range of potentials when compared to standard electrochemical impedance spectroscopy. This current transient approach characterizes the frequency response of the system without the need for expensive frequency response analyzers or software. Copyright 2009 Wiley Periodicals, Inc.
Copper detection in the Asiatic clam Corbicula fluminea: optimum valve closure response.
Tran, Damien; Fournier, Elodie; Durrieu, Gilles; Massabuau, Jean-Charles
2004-02-25
When exposed to a contaminant, bivalves close their shell as a protective strategy. The aim of the present study was to estimate the maximum expected dissolved copper sensitivity in the freshwater bivalve Corbicula fluminea using a new approach to determine their potential and limit to detect contaminants. To take into account the rate of spontaneous closures, we integrated stress problems associated with fixation by a valve in usual valvometers and the spontaneous rhythm associated with nycthemeral activity, to optimize the response in conditions where the probability of spontaneous closing was lowest. Moreover, we used an original system with impedance valvometry, using lightweight impedance electrodes, to study free-ranging animals in low stress conditions combined with an analytical approach describing dose-response curves by logistic regression, with valve closure reaction as a function of response time and concentration of contaminant. In C. fluminea, we estimated that copper concentrations > 4 microg/l (95% confidence interval (CI95%), 2.3-8.8 microg/l) must be detected within 5 h after Cu addition. Lower values could not be distinguished from background noise. The threshold values were 2.5 times lower than the values reported in the literature.
Copper detection in the Asiatic clam Corbicula fluminea: optimum valve closure response.
Tran, Damien; Fournier, Elodie; Durrieu, Gilles; Massabuau, Jean Charles
2003-11-19
When exposed to a contaminant, bivalves close their shell as a protective strategy. The aim of the present study was to estimate the maximum expected dissolved copper sensitivity in the freshwater bivalve Corbicula fluminea using a new approach to determine their potential and limit to detect contaminants. To take into account the rate of spontaneous closures, we integrated stress problems associated with fixation by a valve in usual valvometers and the spontaneous rhythm associated with nycthemeral activity, to optimize the response in conditions where the probability of spontaneous closing was lowest. Moreover, we used an original system with impedance valvometry, using lightweight impedance electrodes, to study free-ranging animals in low stress conditions combined with an analytical approach describing dose-response curves by logistic regression, with valve closure reaction as a function of response time and concentration of contaminant. In C. fluminea, we estimated that copper concentrations >4 microg/l (95% confidence interval (CI(95%)), 2.3-8.8 microg/l) must be detected within 5 h after Cu addition. Lower values could not be distinguished from background noise. The threshold values were 2.5 times higher than the values reported in the literature.
Inverse solution of ear-canal area function from reflectance
Rasetshwane, Daniel M.; Neely, Stephen T.
2011-01-01
A number of acoustical applications require the transformation of acoustical quantities, such as impedance and pressure that are measured at the entrance of the ear canal, to quantities at the eardrum. This transformation often requires knowledge of the shape of the ear canal. Previous attempts to measure ear-canal area functions were either invasive, non-reproducible, or could only measure the area function up to a point mid-way along the canal. A method to determine the area function of the ear canal from measurements of acoustic impedance at the entrance of the ear canal is described. The method is based on a solution to the inverse problem in which measurements of impedance are used to calculate reflectance, which is then used to determine the area function of the canal. The mean ear-canal area function determined using this method is similar to mean ear-canal area functions measured by other researchers using different techniques. The advantage of the proposed method over previous methods is that it is non- invasive, fast, and reproducible. PMID:22225043
Update on Functional Heartburn
Yamasaki, Takahisa; O’Neil, Jessica
2017-01-01
The definition of functional heartburn has been refined over the years. It is currently described, based upon Rome IV criteria, as typical heartburn symptoms in the presence of normal upper endoscopy findings (including normal biopsies), normal esophageal pH testing, and a negative association between symptoms and reflux events. Functional heartburn is very common, affecting women more than men, and with reflux hypersensitivity makes up the majority of heartburn patients who fail twice-daily proton pump inhibitor therapy. These disorders overlap with other functional gastrointestinal disorders and are often accompanied by psychological comorbidities. Diagnosis is made by using endoscopy with esophageal biopsies, wireless pH capsule, pH-impedance monitoring, and high-resolution esophageal manometry. Additional diagnostic tools that may be of value include magnification endoscopy, chromoendoscopy, narrow-band imaging, autofluorescence imaging, mucosal impedance, impedance baseline values, and histopathology scores. Functional heartburn is primarily treated with neuromodulators. Psychological intervention and complementary and alternative medicine may also play important roles in the treatment of these patients. PMID:29339948
Broadband Impedance Microscopy for Research on Complex Quantum Materials
2016-02-08
function in various materials. Figure 2. Sensitivity limit of the broadband impedance microscope (BIM). Figure 3. Preliminary BIM data on YMnO3...2 Statement of the Problem The objective of this DURIP award is to construct a broadband impedance microscope (BIM) for frequency-dependent...platforms and specialized cantilever probes [1] in the PI’s lab, the BIM can now simultaneously obtain microscopic (10 – 100 nm) and quasi- spectroscopic
Impedance dispersion analysis of drug-membrane interactions
NASA Astrophysics Data System (ADS)
Tacheva, Bilyana; Paarvanova, Boyana; Ivanov, Ivan T.; Karabaliev, Miroslav
2017-11-01
Thin lipid films modified glassy carbon electrodes (GCE) were used in this work as model system for studying the interactions between two antipsychotic phenothiazine drugs, chlorpromazine and thioridazine, and the lipid fraction of the biomembranes. The lipid films on the electrode surface were obtained through the thinning of film-forming lipid solution deposited between an electrolyte phase and the working GC electrode. The effects of the drugs on the lipid film structure were investigated by electrochemical impedance spectroscopy (EIS). To characterize the electric properties of the lipid film the impedance of the working GCE is modeled with an equivalent circuit consisting of parallel capacitance Cp and resistance Rp. These capacitance and resistance are not frequency independent but could be calculated as equivalent Cp and Rp for each measured frequency of the impedance spectrum and presented as functions of the frequency f, Cp = Cp(f) and Rp= Rp(f). For the lipid films used in this work, it is demonstrated that both Cp(f) and Rp(f) are well approximated with power-law functions. This behavior implies that the impedance Z of the films could be analysed in terms of the well-known constant-phase angle element (CPE), which is often used to describe the interfacial impedance of solid working electrodes.
An improved multimodal method for sound propagation in nonuniform lined ducts.
Bi, WenPing; Pagneux, Vincent; Lafarge, Denis; Aurégan, Yves
2007-07-01
An efficient method is proposed for modeling time harmonic acoustic propagation in a nonuniform lined duct without flow. The lining impedance is axially segmented uniform, but varies circumferentially. The sound pressure is expanded in term of rigid duct modes and an additional function that carries the information about the impedance boundary. The rigid duct modes and the additional function are known a priori so that calculations of the true liner modes, which are difficult, are avoided. By matching the pressure and axial velocity at the interface between different uniform segments, scattering matrices are obtained for each individual segment; these are then combined to construct a global scattering matrix for multiple segments. The present method is an improvement of the multimodal propagation method, developed in a previous paper [Bi et al., J. Sound Vib. 289, 1091-1111 (2006)]. The radial rate of convergence is improved from O(n(-2)), where n is the radial mode indices, to O(n(-4)). It is numerically shown that using the present method, acoustic propagation in the nonuniform lined intake of an aeroengine can be calculated by a personal computer for dimensionless frequency K up to 80, approaching the third blade passing frequency of turbofan noise.
Accurate position estimation methods based on electrical impedance tomography measurements
NASA Astrophysics Data System (ADS)
Vergara, Samuel; Sbarbaro, Daniel; Johansen, T. A.
2017-08-01
Electrical impedance tomography (EIT) is a technology that estimates the electrical properties of a body or a cross section. Its main advantages are its non-invasiveness, low cost and operation free of radiation. The estimation of the conductivity field leads to low resolution images compared with other technologies, and high computational cost. However, in many applications the target information lies in a low intrinsic dimensionality of the conductivity field. The estimation of this low-dimensional information is addressed in this work. It proposes optimization-based and data-driven approaches for estimating this low-dimensional information. The accuracy of the results obtained with these approaches depends on modelling and experimental conditions. Optimization approaches are sensitive to model discretization, type of cost function and searching algorithms. Data-driven methods are sensitive to the assumed model structure and the data set used for parameter estimation. The system configuration and experimental conditions, such as number of electrodes and signal-to-noise ratio (SNR), also have an impact on the results. In order to illustrate the effects of all these factors, the position estimation of a circular anomaly is addressed. Optimization methods based on weighted error cost functions and derivate-free optimization algorithms provided the best results. Data-driven approaches based on linear models provided, in this case, good estimates, but the use of nonlinear models enhanced the estimation accuracy. The results obtained by optimization-based algorithms were less sensitive to experimental conditions, such as number of electrodes and SNR, than data-driven approaches. Position estimation mean squared errors for simulation and experimental conditions were more than twice for the optimization-based approaches compared with the data-driven ones. The experimental position estimation mean squared error of the data-driven models using a 16-electrode setup was less than 0.05% of the tomograph radius value. These results demonstrate that the proposed approaches can estimate an object’s position accurately based on EIT measurements if enough process information is available for training or modelling. Since they do not require complex calculations it is possible to use them in real-time applications without requiring high-performance computers.
Haines, Jillian M; Thomason, John M; Seage, Eileen C; Wills, Robert W; Bulla, Camilo; Lunsford, Kari V; Mackin, Andrew J
2016-02-01
To assess the in vitro and in vivo platelet function of healthy dogs during administration of a low-dose aspirin regimen. 16 dogs. Dogs received aspirin (1 mg/kg, PO, q 24 h) for 7 days. Blood and urine samples were collected before (day 1; baseline) and on days 3 and 7 of the low-dose aspirin regimen. Platelet function was evaluated by use of turbidimetric and conventional impedance aggregometry, multiple-electrode impedance aggregometry, a platelet function analyzer (PFA), and determination of urine 11-dehydro-thromboxane B2 concentration. Turbidimetric aggregometry results were compared with the results obtained by the other 4 methods. Fourteen days after cessation of aspirin, platelet-rich plasma was incubated with acetylsalicylic acid and platelet function was assessed by turbidimetric aggregometry to determine whether this technique could accurately identify dogs that responded to the low-dose aspirin regimen. Of the 16 dogs, 13 had turbidimetric and conventional impedance aggregometry results that were decreased by > 25% from baseline on days 3 and 7, and 4 and 7 dogs had PFA closure times > 300 seconds on days 3 and 7, respectively. The median urine 11-dehydro-thromboxane B2 concentration-to-creatinine concentration ratio decreased by 49% between days 1 and 7. Turbidimetric aggregometry results were correlated with conventional impedance aggregometry results. There was poor agreement between the turbidimetric aggregometry and PFA results. The multiple-electrode impedance aggregometry protocol failed to reliably detect aspirin-induced platelet dysfunction. In vitro incubation of platelet-rich plasma with acetylsalicylic acid followed by turbidimetric aggregometry did not predict whether dogs responded to the low-dose aspirin regimen. Results indicated that the response to a low-dose aspirin regimen varied among healthy dogs.
Noncontact Measurement Of Sizes And Eccentricities Of Holes
NASA Technical Reports Server (NTRS)
Chern, Engmin J.
1993-01-01
Semiautomatic eddy-current-probe apparatus makes noncontact measurements of nominally round holes in electrically conductive specimens and processes measurement data into diameters and eccentricities of holes. Includes x-y translation platform, which holds specimen and moves it horizontally. Probe mounted on probe scanner, positioning probe along vertical (z) direction and rotates probe about vertical axis at preset low speed. Eddy-current sensing coil mounted in side of probe near tip. As probe rotates, impedance analyzer measures electrical impedance (Z) of coil as function of instantaneous rotation angle. Translation and rotation mechanisms and impedance analyzer controlled by computer, which also processes impedance-measurement data.
An improved water-filled impedance tube.
Wilson, Preston S; Roy, Ronald A; Carey, William M
2003-06-01
A water-filled impedance tube capable of improved measurement accuracy and precision is reported. The measurement instrument employs a variation of the standardized two-sensor transfer function technique. Performance improvements were achieved through minimization of elastic waveguide effects and through the use of sound-hard wall-mounted acoustic pressure sensors. Acoustic propagation inside the water-filled impedance tube was found to be well described by a plane wave model, which is a necessary condition for the technique. Measurements of the impedance of a pressure-release terminated transmission line, and the reflection coefficient from a water/air interface, were used to verify the system.
Tracking of electrochemical impedance of batteries
NASA Astrophysics Data System (ADS)
Piret, H.; Granjon, P.; Guillet, N.; Cattin, V.
2016-04-01
This paper presents an evolutionary battery impedance estimation method, which can be easily embedded in vehicles or nomad devices. The proposed method not only allows an accurate frequency impedance estimation, but also a tracking of its temporal evolution contrary to classical electrochemical impedance spectroscopy methods. Taking into account constraints of cost and complexity, we propose to use the existing electronics of current control to perform a frequency evolutionary estimation of the electrochemical impedance. The developed method uses a simple wideband input signal, and relies on a recursive local average of Fourier transforms. The averaging is controlled by a single parameter, managing a trade-off between tracking and estimation performance. This normalized parameter allows to correctly adapt the behavior of the proposed estimator to the variations of the impedance. The advantage of the proposed method is twofold: the method is easy to embed into a simple electronic circuit, and the battery impedance estimator is evolutionary. The ability of the method to monitor the impedance over time is demonstrated on a simulator, and on a real Lithium ion battery, on which a repeatability study is carried out. The experiments reveal good tracking results, and estimation performance as accurate as the usual laboratory approaches.
NASA Technical Reports Server (NTRS)
Mehling, Joshua S.; Holley, James; O'Malley, Marcia K.
2015-01-01
The fidelity with which series elastic actuators (SEAs) render desired impedances is important. Numerous approaches to SEA impedance control have been developed under the premise that high-precision actuator torque control is a prerequisite. Indeed, the design of an inner torque compensator has a significant impact on actuator impedance rendering. The disturbance observer (DOB) based torque control implemented in NASA's Valkyrie robot is considered here and a mathematical model of this torque control, cascaded with an outer impedance compensator, is constructed. While previous work has examined the impact a disturbance observer has on torque control performance, little has been done regarding DOBs and impedance rendering accuracy. Both simulation and a series of experiments are used to demonstrate the significant improvements possible in an SEA's ability to render desired dynamic behaviors when utilizing a DOB. Actuator transparency at low impedances is improved, closed loop hysteresis is reduced, and the actuator's dynamic response to both commands and interaction torques more faithfully matches that of the desired model. All of this is achieved by leveraging DOB based control rather than increasing compensator gains, thus making improved SEA impedance control easier to achieve in practice.
Chang, Pyung Hun; Kang, Sang Hoon
2010-05-30
The basic assumption of stochastic human arm impedance estimation methods is that the human arm and robot behave linearly for small perturbations. In the present work, we have identified the degree of influence of nonlinear friction in robot joints to the stochastic human arm impedance estimation. Internal model based impedance control (IMBIC) is then proposed as a means to make the estimation accurate by compensating for the nonlinear friction. From simulations with a nonlinear Lugre friction model, it is observed that the reliability and accuracy of the estimation are severely degraded with nonlinear friction: below 2 Hz, multiple and partial coherence functions are far less than unity; estimated magnitudes and phases are severely deviated from that of a real human arm throughout the frequency range of interest; and the accuracy is not enhanced with an increase of magnitude of the force perturbations. In contrast, the combined use of stochastic estimation and IMBIC provides with accurate estimation results even with large friction: the multiple coherence functions are larger than 0.9 throughout the frequency range of interest and the estimated magnitudes and phases are well matched with that of a real human arm. Furthermore, the performance of suggested method is independent of human arm and robot posture, and human arm impedance. Therefore, the IMBIC will be useful in measuring human arm impedance with conventional robot, as well as in designing a spatial impedance measuring robot, which requires gearing. (c) 2010 Elsevier B.V. All rights reserved.
A dual marker label free electrochemical assay for Flavivirus dengue diagnosis.
Santos, Adriano; Bueno, Paulo R; Davis, Jason J
2018-02-15
Dengue is a RNA viral illness of the genus Flavivirus which can cause, depending on the pervasiveness of the infection, hemorrhagic dengue fever or dengue shock syndrome. Herein we present an electrochemical label free approach enabling the rapid sensitive quantification of NS1 and IgG (supporting an ability to distinguish primary and secondary infections). Using a bifunctional SAM containing PEG moieties and a tethered redox thiol, both markers are detectable across clinically relevant levels by label free impedance derived redox capacitance. A subsequent frequency specific immittance function approach enables assaying (within seconds) with no impairment of analytical quality (linearity, sensitivity and variance). Copyright © 2017 Elsevier B.V. All rights reserved.
Manipulating Acoustic Wavefront by Inhomogeneous Impedance and Steerable Extraordinary Reflection
Zhao, Jiajun; Li, Baowen; Chen, Zhining; Qiu, Cheng-Wei
2013-01-01
We unveil the connection between the acoustic impedance along a flat surface and the reflected acoustic wavefront, in order to empower a wide wariety of novel applications in acoustic community. Our designed flat surface can generate double reflections: the ordinary reflection and the extraordinary one whose wavefront is manipulated by the proposed impedance-governed generalized Snell's law of reflection (IGSL). IGSL is based on Green's function and integral equation, instead of Fermat's principle for optical wavefront manipulation. Remarkably, via the adjustment of the designed specific acoustic impedance, extraordinary reflection can be steered for unprecedented acoustic wavefront while that ordinary reflection can be surprisingly switched on or off. The realization of the complex discontinuity of the impedance surface has been proposed using Helmholtz resonators. PMID:23985717
Earth impedance model for through-the-earth communication applications with electrodes
NASA Astrophysics Data System (ADS)
Bataller, Vanessa; MuñOz, Antonio; Gaudó, Pilar Molina; Mediano, Arturo; Cuchí, José A.; Villarroel, José L.
2010-12-01
Through-the-earth (TTE) communications are relevant in applications such as caving, tunnel and cave rescue, mining, and subsurface radiolocation. The majority of the TTE communication systems use ground electrodes as load antenna. Wires, electrode contact, and earth impedances are the major contributors to the impedance observed by the transmitter. In this paper, state-of-art models found in the literature are reviewed, and an improved method to measure the earth impedance is presented. The paper also proposes an optimal circuit model for earth impedance between electrodes as a function of frequency, as a consequence of the particular conditions of the application. The model is validated with measurements for different soil conditions, showing a good agreement between empirical data and the simulation results.
One-port portable SAW sensor system
NASA Astrophysics Data System (ADS)
Hoa Nguyen, Vu; Peters, Oliver; Schnakenberg, Uwe
2018-01-01
A portable device using the SAW-based impedance sensor type based on one interdigital transducer simultaneously as SAW generator and sensor element (1-port approach) is introduced. As a novelty, the so far required expensive vector network analyzer (VNA) is replaced by a hand-held device to measure the impedance spectrum of the SAW sensor by RF-gain-phase meters. Hence, some of the best features from the conventional oscillator and VNA approaches are combined to develop a low-cost and self-contained measurement system, including signal in- and output ability for real-time measurements. The pivotal aspect of the portable system is the transfer of the sophisticated high frequency approach into a quasi-static one. This enables the use of simple lumped electronics without the need of impedance matching circuits. Proof-of-concept was carried out by measuring conductivities of phosphate-buffered solutions and viscosities of glycerin. Sensitivities for temperature of 0.3%/°C, viscosity of 10.1% (mPa s)-1 and conductivity of 0.5% (S cm)-1 have been determined, respectively, which are competitive results compared to the benchmark approaches.
Bourlier, Christophe; Kubické, Gildas; Déchamps, Nicolas
2008-04-01
A fast, exact numerical method based on the method of moments (MM) is developed to calculate the scattering from an object below a randomly rough surface. Déchamps et al. [J. Opt. Soc. Am. A23, 359 (2006)] have recently developed the PILE (propagation-inside-layer expansion) method for a stack of two one-dimensional rough interfaces separating homogeneous media. From the inversion of the impedance matrix by block (in which two impedance matrices of each interface and two coupling matrices are involved), this method allows one to calculate separately and exactly the multiple-scattering contributions inside the layer in which the inverses of the impedance matrices of each interface are involved. Our purpose here is to apply this method for an object below a rough surface. In addition, to invert a matrix of large size, the forward-backward spectral acceleration (FB-SA) approach of complexity O(N) (N is the number of unknowns on the interface) proposed by Chou and Johnson [Radio Sci.33, 1277 (1998)] is applied. The new method, PILE combined with FB-SA, is tested on perfectly conducting circular and elliptic cylinders located below a dielectric rough interface obeying a Gaussian process with Gaussian and exponential height autocorrelation functions.
Yan Hong; Yong Wang; Wang Ling Goh; Yuan Gao; Lei Yao
2015-08-01
This paper presents a mathematic method and a cost-efficient circuit to measure the value of each component of the bio-impedance model at electrode-electrolyte interface. The proposed current excited triple-time-voltage oversampling (TTVO) method deduces the component values by solving triple simultaneous electric equation (TSEE) at different time nodes during a current excitation, which are the voltage functions of time. The proposed triple simultaneous electric equations (TSEEs) allows random selections of the time nodes, hence numerous solutions can be obtained during a single current excitation. Following that, the oversampling approach is engaged by averaging all solutions of multiple TSEEs acquired after a single current excitation, which increases the practical measurement accuracy through the improvement of the signal-to-noise ratio (SNR). In addition, a print circuit board (PCB) that consists a switched current exciter and an analog-to-digital converter (ADC) is designed for signal acquisition. This presents a great cost reduction when compared against other instrument-based measurement data reported [1]. Through testing, the measured values of this work is proven to be in superb agreements on the true component values of the electrode-electrolyte interface model. This work is most suited and also useful for biological and biomedical applications, to perform tasks such as stimulations, recordings, impedance characterizations, etc.
Reduction of turbulent boundary layer induced interior noise through active impedance control.
Remington, Paul J; Curtis, Alan R D; Coleman, Ronald B; Knight, J Scott
2008-03-01
The use of a single actuator tuned to an optimum impedance to control the sound power radiated from a turbulent boundary layer (TBL) excited aircraft panel into the aircraft interior is examined. An approach to calculating the optimum impedance is defined and the limitations on the reduction in radiated power by a single actuator tuned to that impedance are examined. It is shown that there are too many degrees of freedom in the TBL and in the radiation modes of the panel to allow a single actuator to control the radiated power. However, if the panel modes are lightly damped and well separated in frequency, significant reductions are possible. The implementation of a controller that presents a desired impedance to a structure is demonstrated in a laboratory experiment, in which the structure is a mass. The performance of such a controller on an aircraft panel is shown to be effective, if the actuator impedance is similar to but not the same as the desired impedance, provided the panel resonances are well separated in frequency and lightly damped.
Electrical Impedance Spectroscopy Study of Biological Tissues
Dean, D.A.; Ramanathan, T.; Machado, D.; Sundararajan, R.
2008-01-01
The objective of this study was to investigate the electrical impedance properties of rat lung and other tissues ex vivo using Electrical Impedance Spectroscopy. Rat lungs (both electroporated and naïve (untreated)), and mesenteric vessels (naïve) were harvested from male Sprague-Dawley rats; their electrical impedance were measured using a Solartron 1290 impedance analyzer. Mouse lung and heart samples (naïve) were also studied. The resistance (Real Z, ohm) and the reactance (Im Z, negative ohm)) magnitudes and hence the Cole-Cole (Real Z versus Im Z) plots are different for the electroporated lung and the naive lung. The results confirm the close relationship between the structure and the functional characteristic. These also vary for the different biological tissues studied. The impedance values were higher at low frequencies compared to those at high frequencies. This study is of practical interest for biological applications of electrical pulses, such as electroporation, whose efficacy depends on cell type and its electrical impedance characteristics. PMID:19255614
A Numerical Theory for Impedance Education in Three-Dimensional Normal Incidence Tubes
NASA Technical Reports Server (NTRS)
Watson, Willie R.; Jones, Michael G.
2016-01-01
A method for educing the locally-reacting acoustic impedance of a test sample mounted in a 3-D normal incidence impedance tube is presented and validated. The unique feature of the method is that the excitation frequency (or duct geometry) may be such that high-order duct modes may exist. The method educes the impedance, iteratively, by minimizing an objective function consisting of the difference between the measured and numerically computed acoustic pressure at preselected measurement points in the duct. The method is validated on planar and high-order mode sources with data synthesized from exact mode theory. These data are then subjected to random jitter to simulate the effects of measurement uncertainties on the educed impedance spectrum. The primary conclusions of the study are 1) Without random jitter the method is in excellent agreement with that for known impedance samples, and 2) Random jitter that is compatible to that found in a typical experiment has minimal impact on the accuracy of the educed impedance.
Boverman, Gregory; Isaacson, David; Newell, Jonathan C; Saulnier, Gary J; Kao, Tzu-Jen; Amm, Bruce C; Wang, Xin; Davenport, David M; Chong, David H; Sahni, Rakesh; Ashe, Jeffrey M
2017-04-01
In electrical impedance tomography (EIT), we apply patterns of currents on a set of electrodes at the external boundary of an object, measure the resulting potentials at the electrodes, and, given the aggregate dataset, reconstruct the complex conductivity and permittivity within the object. It is possible to maximize sensitivity to internal conductivity changes by simultaneously applying currents and measuring potentials on all electrodes but this approach also maximizes sensitivity to changes in impedance at the interface. We have, therefore, developed algorithms to assess contact impedance changes at the interface as well as to efficiently and simultaneously reconstruct internal conductivity/permittivity changes within the body. We use simple linear algebraic manipulations, the generalized singular value decomposition, and a dual-mesh finite-element-based framework to reconstruct images in real time. We are also able to efficiently compute the linearized reconstruction for a wide range of regularization parameters and to compute both the generalized cross-validation parameter as well as the L-curve, objective approaches to determining the optimal regularization parameter, in a similarly efficient manner. Results are shown using data from a normal subject and from a clinical intensive care unit patient, both acquired with the GE GENESIS prototype EIT system, demonstrating significantly reduced boundary artifacts due to electrode drift and motion artifact.
Uncertainty Analysis of the Grazing Flow Impedance Tube
NASA Technical Reports Server (NTRS)
Brown, Martha C.; Jones, Michael G.; Watson, Willie R.
2012-01-01
This paper outlines a methodology to identify the measurement uncertainty of NASA Langley s Grazing Flow Impedance Tube (GFIT) over its operating range, and to identify the parameters that most significantly contribute to the acoustic impedance prediction. Two acoustic liners are used for this study. The first is a single-layer, perforate-over-honeycomb liner that is nonlinear with respect to sound pressure level. The second consists of a wire-mesh facesheet and a honeycomb core, and is linear with respect to sound pressure level. These liners allow for evaluation of the effects of measurement uncertainty on impedances educed with linear and nonlinear liners. In general, the measurement uncertainty is observed to be larger for the nonlinear liners, with the largest uncertainty occurring near anti-resonance. A sensitivity analysis of the aerodynamic parameters (Mach number, static temperature, and static pressure) used in the impedance eduction process is also conducted using a Monte-Carlo approach. This sensitivity analysis demonstrates that the impedance eduction process is virtually insensitive to each of these parameters.
Finite difference time domain implementation of surface impedance boundary conditions
NASA Technical Reports Server (NTRS)
Beggs, John H.; Luebbers, Raymond J.; Yee, Kane S.; Kunz, Karl S.
1991-01-01
Surface impedance boundary conditions are employed to reduce the solution volume during the analysis of scattering from lossy dielectric objects. In the finite difference solution, they also can be utilized to avoid using small cells, made necessary by shorter wavelengths in conducting media throughout the solution volume. The standard approach is to approximate the surface impedance over a very small bandwidth by its value at the center frequency, and then use that result in the boundary condition. Here, two implementations of the surface impedance boundary condition are presented. One implementation is a constant surface impedance boundary condition and the other is a dispersive surface impedance boundary condition that is applicable over a very large frequency bandwidth and over a large range of conductivities. Frequency domain results are presented in one dimension for two conductivity values and are compared with exact results. Scattering width results from an infinite square cylinder are presented as a two dimensional demonstration. Extensions to three dimensions should be straightforward.
Finite difference time domain implementation of surface impedance boundary conditions
NASA Technical Reports Server (NTRS)
Beggs, John H.; Luebbers, Raymond J.; Yee, Kane S.; Kunz, Karl S.
1991-01-01
Surface impedance boundary conditions are employed to reduce the solution volume during the analysis of scattering from lossy dielectric objects. In a finite difference solution, they also can be utilized to avoid using small cells, made necessary by shorter wavelengths in conducting media throughout the solution volume. The standard approach is to approximate the surface impedance over a very small bandwidth by its value at the center frequency, and then use that result in the boundary condition. Two implementations of the surface impedance boundary condition are presented. One implementation is a constant surface impedance boundary condition and the other is a dispersive surface impedance boundary condition that is applicable over a very large frequency bandwidth and over a large range of conductivities. Frequency domain results are presented in one dimension for two conductivity values and are compared with exact results. Scattering width results from an infinite square cylinder are presented as a 2-D demonstration. Extensions to 3-D should be straightforward.
Active sensors for health monitoring of aging aerospace structures
NASA Astrophysics Data System (ADS)
Giurgiutiu, Victor; Redmond, James M.; Roach, Dennis P.; Rackow, Kirk
2000-06-01
A project to develop non-intrusive active sensors that can be applied on existing aging aerospace structures for monitoring the onset and progress of structural damage (fatigue cracks and corrosion) is presented. The state of the art in active sensors structural health monitoring and damage detection is reviewed. Methods based on (a) elastic wave propagation and (b) electro-mechanical (E/M) impedance technique are cited and briefly discussed. The instrumentation of these specimens with piezoelectric active sensors is illustrated. The main detection strategies (E/M impedance for local area detection and wave propagation for wide area interrogation) are discussed. The signal processing and damage interpretation algorithms are tuned to the specific structural interrogation method used. In the high frequency E/M impedance approach, pattern recognition methods are used to compare impedance signatures taken at various time intervals and to identify damage presence and progression from the change in these signatures. In the wave propagation approach, the acousto- ultrasonic methods identifying additional reflection generated from the damage site and changes in transmission velocity and phase are used. Both approaches benefit from the use of artificial intelligence neural networks algorithms that can extract damage features based on a learning process. Design and fabrication of a set of structural specimens representative of aging aerospace structures is presented. Three built-up specimens, (pristine, with cracks, and with corrosion damage) are used. The specimen instrumentation with active sensors fabricated at the University of South Carolina is illustrated. Preliminary results obtained with the E/M impedance method on pristine and cracked specimens are presented.
Subglottal Impedance-Based Inverse Filtering of Voiced Sounds Using Neck Surface Acceleration
Zañartu, Matías; Ho, Julio C.; Mehta, Daryush D.; Hillman, Robert E.; Wodicka, George R.
2014-01-01
A model-based inverse filtering scheme is proposed for an accurate, non-invasive estimation of the aerodynamic source of voiced sounds at the glottis. The approach, referred to as subglottal impedance-based inverse filtering (IBIF), takes as input the signal from a lightweight accelerometer placed on the skin over the extrathoracic trachea and yields estimates of glottal airflow and its time derivative, offering important advantages over traditional methods that deal with the supraglottal vocal tract. The proposed scheme is based on mechano-acoustic impedance representations from a physiologically-based transmission line model and a lumped skin surface representation. A subject-specific calibration protocol is used to account for individual adjustments of subglottal impedance parameters and mechanical properties of the skin. Preliminary results for sustained vowels with various voice qualities show that the subglottal IBIF scheme yields comparable estimates with respect to current aerodynamics-based methods of clinical vocal assessment. A mean absolute error of less than 10% was observed for two glottal airflow measures –maximum flow declination rate and amplitude of the modulation component– that have been associated with the pathophysiology of some common voice disorders caused by faulty and/or abusive patterns of vocal behavior (i.e., vocal hyperfunction). The proposed method further advances the ambulatory assessment of vocal function based on the neck acceleration signal, that previously have been limited to the estimation of phonation duration, loudness, and pitch. Subglottal IBIF is also suitable for other ambulatory applications in speech communication, in which further evaluation is underway. PMID:25400531
Marincola, Mauro; Lombardo, Giorgio; Pighi, Jacopo; Corrocher, Giovanni; Mascellaro, Anna; Lehrberg, Jeffrey; Nocini, Pier Francesco
2015-01-01
The functional and aesthetic restoration of teeth compromised due to aggressive periodontitis presents numerous challenges for the clinician. Horizontal bone loss and soft tissue destruction resulting from periodontitis can impede implant placement and the regeneration of an aesthetically pleasing gingival smile line, often requiring bone augmentation and mucogingival surgery, respectively. Conservative approaches to the treatment of aggressive periodontitis (i.e., treatments that use minimally invasive tools and techniques) have been purported to yield positive outcomes. Here, we report on the treatment and five-year follow-up of patient suffering from aggressive periodontitis using a minimally invasive surgical technique and implant system. By using the methods described herein, we were able to achieve the immediate aesthetic and functional restoration of the maxillary incisors in a case that would otherwise require bone augmentation and extensive mucogingival surgery. This technique represents a conservative and efficacious alternative to the aesthetic and functional replacement of teeth compromised due to aggressive periodontitis. PMID:26649207
Toward high throughput optical metamaterial assemblies.
Fontana, Jake; Ratna, Banahalli R
2015-11-01
Optical metamaterials have unique engineered optical properties. These properties arise from the careful organization of plasmonic elements. Transitioning these properties from laboratory experiments to functional materials may lead to disruptive technologies for controlling light. A significant issue impeding the realization of optical metamaterial devices is the need for robust and efficient assembly strategies to govern the order of the nanometer-sized elements while enabling macroscopic throughput. This mini-review critically highlights recent approaches and challenges in creating these artificial materials. As the ability to assemble optical metamaterials improves, new unforeseen opportunities may arise for revolutionary optical devices.
Computational Modeling of Piezoelectric Foams
NASA Astrophysics Data System (ADS)
Challagulla, K. S.; Venkatesh, T. A.
2013-02-01
Piezoelectric materials, by virtue of their unique electromechanical characteristics, have been recognized for their potential utility in many applications as sensors and actuators. However, the sensing or actuating functionality of monolithic piezoelectric materials is generally limited. The composite approach to piezoelectric materials provides a unique opportunity to access a new design space with optimal mechanical and coupled characteristics. The properties of monolithic piezoelectric materials can be enhanced via the additive approach by adding two or more constituents to create several types of piezoelectric composites or via the subtractive approach by introducing controlled porosity in the matrix materials to create porous piezoelectric materials. Such porous piezoelectrics can be tailored to demonstrate improved signal-to-noise ratio, impedance matching, and sensitivity, and thus, they can be optimized for applications such as hydrophone devices. This article captures key results from the recent developments in the field of computational modeling of novel piezoelectric foam structures. It is demonstrated that the fundamental elastic, dielectric, and piezoelectric properties of piezoelectric foam are strongly dependent on the internal structure of the foams and the material volume fraction. The highest piezoelectric coupling constants and the highest acoustic impedance are obtained in the [3-3] interconnect-free piezoelectric foam structures, while the corresponding figures of merit for the [3-1] type long-porous structure are marginally higher. Among the [3-3] type foam structures, the sparsely-packed foam structures (with longer and thicker interconnects) display higher coupling constants and acoustic impedance as compared to closepacked foam structures (with shorter and thinner interconnects). The piezoelectric charge coefficients ( d h), the hydrostatic voltage coefficients ( g h), and the hydrostatic figures of merit ( d hgh) are observed to be significantly higher for the [3-3] type piezoelectric foam structures as compared to the [3-1] type long-porous materials, and these can be enhanced significantly by modifying the aspect ratio of the porosity in the foam structures as well.
Evaluation of esophageal motor function in clinical practice.
Gyawali, C P; Bredenoord, A J; Conklin, J L; Fox, M; Pandolfino, J E; Peters, J H; Roman, S; Staiano, A; Vaezi, M F
2013-02-01
Esophageal motor function is highly coordinated between central and enteric nervous systems and the esophageal musculature, which consists of proximal skeletal and distal smooth muscle in three functional regions, the upper and lower esophageal sphincters, and the esophageal body. While upper endoscopy is useful in evaluating for structural disorders of the esophagus, barium esophagography, radionuclide transit studies, and esophageal intraluminal impedance evaluate esophageal transit and partially assess motor function. However, esophageal manometry is the test of choice for the evaluation of esophageal motor function. In recent years, high-resolution manometry (HRM) has streamlined the process of acquisition and display of esophageal pressure data, while uncovering hitherto unrecognized esophageal physiologic mechanisms and pathophysiologic patterns. New algorithms have been devised for analysis and reporting of esophageal pressure topography from HRM. The clinical value of HRM extends to the pediatric population, and complements preoperative evaluation prior to foregut surgery. Provocative maneuvers during HRM may add to the assessment of esophageal motor function. The addition of impedance to HRM provides bolus transit data, but impact on clinical management remains unclear. Emerging techniques such as 3-D HRM and impedance planimetry show promise in the assessment of esophageal sphincter function and esophageal biomechanics. © 2013 Blackwell Publishing Ltd.
NASA Astrophysics Data System (ADS)
Tam, Kai-Chung; Lau, Siu-Kit; Tang, Shiu-Keung
2016-07-01
A microphone array signal processing method for locating a stationary point source over a locally reactive ground and for estimating ground impedance is examined in detail in the present study. A non-linear least square approach using the Levenberg-Marquardt method is proposed to overcome the problem of unknown ground impedance. The multiple signal classification method (MUSIC) is used to give the initial estimation of the source location, while the technique of forward backward spatial smoothing is adopted as a pre-processer of the source localization to minimize the effects of source coherence. The accuracy and robustness of the proposed signal processing method are examined. Results show that source localization in the horizontal direction by MUSIC is satisfactory. However, source coherence reduces drastically the accuracy in estimating the source height. The further application of Levenberg-Marquardt method with the results from MUSIC as the initial inputs improves significantly the accuracy of source height estimation. The present proposed method provides effective and robust estimation of the ground surface impedance.
NASA Astrophysics Data System (ADS)
Ishii, H.; Kojima, H.; Fukuhara, H.; Okada, S.; Yamakawa, H.
2012-04-01
Plasma wave is one of the most essential physical quantities in the solar terrestrial physics. The role of plasma wave receiver onboard satellites is to detect plasma waves in space with a good signal to noise ratio. There are two types of plasma wave receivers, the sweep frequency analyzer and the waveform capture. While the sweep frequency analyzer provides plasma wave spectra, the waveform capture obtains waveforms with phase information that is significant in studying nonlinear phenomena. Antenna sensors to observe electric fields of the plasma waves show different features in plasmas from in vacuum. The antenna impedances have specific characteristics in the frequency domain because of the dispersion of plasmas. These antenna impedances are expressed with complex number. We need to know not only the antenna impedances but also the transfer functions of plasma wave receiver's circuits in order to calibrate observed waveforms precisely. The impedances of the electric field antennas are affected by a state of surrounding plasmas. Since satellites run through various regions with different plasma parameters, we precisely should measure the antenna impedances onboard spacecraft. On the contrary, we can obtain the plasma density and by measuring the antenna impedances. Several formulas of the antenna impedance measurement system were proposed. A synchronous detection method is used on the BepiColombo Mercury Magnetospheric Orbiter (MMO), which will be launched in 2014. The digital data are stored in the onboard memory. They are read out and converted to the analog waveforms by D/A converter. They are fed into the input of the preamplifiers of antenna sensors through a resistor. We can calculate a transfer function of the circuit by applying the synchronous detection method to the output waveform from waveform receivers and digital data as a signal source. The size of this system is same as an A5 board. In recent years, Application Specific Integrated Circuit (ASIC) is in attention which is a technique to integrate large scale and complicated circuits. Lots of ASICs have been applied to high energy astrophysics. In this paper, we show our attempt to miniaturize the antennas impedances measurement system and Waveform Capture using the analogue ASIC. We design 8bits segment D/A converter that is implemented inside the waveform receiver ASIC chip. We improve input logic of the D/A converter to generate very weak signals accurately. The designed chip realizes the measurement of the antenna impedance as well as the waveform observation in the board size of business cards.
Non-Contact EDDY Current Hole Eccentricity and Diameter Measurement
NASA Technical Reports Server (NTRS)
Chern, E. James
1998-01-01
Precision holes are among the most critical features of a mechanical component. Deviations from permissible tolerances can impede operation and result in unexpected failure. We have developed an automated non-contact eddy current hole diameter and eccentricity measuring system. The operating principle is based on the eddy current lift-off effect, which is the coil impedance as a function of the distance between the coil and the test object. An absolute eddy current probe rotates in the hole. The impedance of each angular position is acquired and input to the computer for integration and analysis. The eccentricity of the hole is the profile of the impedance as a function of angular position as compared to a straight line, an ideal hole. The diameter of the hole is the sum of the diameter of the probe and twice the distance-calibrated impedance. An eddy current image is generated by integrating angular scans for a plurality of depths between the top and bottom to display the eccentricity profile. This system can also detect and image defects in the hole. The method for non-contact eddy current hole diameter and eccentricity measurement has been granted a patent by the U.S. Patent and Trademark Office.
A 17 degree of freedom anthropomorphic manipulator
NASA Technical Reports Server (NTRS)
Vold, Havard I.; Karlen, James P.; Thompson, Jack M., Jr.; Farrell, James D.; Eismann, Paul H.
1989-01-01
A 17 axis anthropomorphic manipulator, providing coordinated control of two seven degree of freedom arms mounted on a three degree of freedom torso-waist assembly, is presented. This massively redundant telerobot, designated the Robotics Research K/B-2017 Dexterous Manipulator, employs a modular mechanism design with joint-mounted actuators based on brushless motors and harmonic drive gear reducers. Direct joint torque control at the servo level causes these high-output joint drives to behave like direct-drive actuators, facilitating the implementation of an effective impedance control scheme. The redundant, but conservative motion control system models the manipulator as a spring-loaded linkage with viscous damping and rotary inertia at each joint. This approach allows for real time, sensor-driven control of manipulator pose using a hierarchy of competing rules, or objective functions, to avoid unplanned collisions with objects in the workplace, to produce energy-efficient, graceful motion, to increase leverage, to control effective impedance at the tool or to favor overloaded joints.
Majority of symptoms in esophageal reflux PPI non-responders are not related to reflux
Roman, Sabine; Keefer, Laurie; Imam, Hala; Korrapati, Praneet; Mogni, Benjamin; Eident, Kate; Friesen, Laurel; Kahrilas, Peter J; Martinovich, Zoran; Pandolfino, John
2015-01-01
Background Genesis of persistent gastro-esophageal reflux symptoms despite proton pump inhibitor (PPI) therapy is not fully understood. We aimed at determining reflux patterns on 24-h pH-impedance monitoring performed on PPI and correlating impedance patterns and symptom occurrence in PPI non-responders. Methods 78 PPI non-responder patients underwent 24-h pH-impedance monitoring on PPI. Reflux impedance characterization included gastric and supragastric belches and proximal extent of reflux. Symptoms were considered associated with reflux if occurring within 5 min after a reflux event. Patients were classified into 3 groups: persistent acid reflux (acid esophageal exposure (AET) >5% of time), reflux sensitivity (AET<5%, symptom index (SI) ≥50%), and functional symptoms (AET<5%, SI<50%). Dominant impedance pattern was determined for each patient. Key results 7 patients (9%) had persistent acid reflux, 28 (36%) reflux sensitivity and 43 (55%) functional symptoms. A total of 4,296 reflux events were identified (median per patient 45 (range 4–221)). Although liquid reflux was the most common pattern in all groups, patients with reflux sensitivity and functional symptoms had much more variability in their pattern profile with a large proportion being associated with gastric and supra-gastric belching. Only 417 reflux events (9.7%) were associated with symptoms. Reflux with a supragastric component and proximal extent were more likely to be associated with symptoms. Conclusions & Inferences The impedance reflux profile in PPI non-responders was heterogeneous and the majority of reflux events were not associated with symptoms. Thus, the treatment of PPI non-responders should focus on mechanisms beyond reflux, such as visceral hypersensitivity and hypervigilance. PMID:26337396
Peterson, G W; McEntee, M; Harris, C R; Klevitch, A D; Fountain, A W; Soliz, J R; Balboa, A; Hauser, A J
2016-11-01
Electrical impedance spectroscopy, in conjunction with the metal-organic framework (MOF) UiO-66-NH 2 , is used to detect trace levels of the explosive simulant 2,6-dinitrotoluene. The combination of porosity and functionality of the MOF provides an effective dielectric structure, resulting in changes of impedance magnitude and phase angle. The promising data indicate that MOFs may be used in low-cost, robust explosive detection devices.
Vijay, Viswam; Raziyeh, Bounik; Amir, Shadmani; Jelena, Dragas; Alicia, Boos Julia; Axel, Birchler; Jan, Müller; Yihui, Chen; Andreas, Hierlemann
2017-01-26
A monolithic measurement platform was implemented to enable label-free in-vitro electrical impedance spectroscopy measurements of cells on multi-functional CMOS microelectrode array. The array includes 59,760 platinum microelectrodes, densely packed within a 4.5 mm × 2.5 mm sensing region at a pitch of 13.5 μm. The 32 on-chip lock-in amplifiers can be used to measure the impedance of any arbitrarily chosen electrodes on the array by applying a sinusoidal voltage, generated by an on-chip waveform generator with a frequency range from 1 Hz to 1 MHz, and measuring the respective current. Proof-of-concept measurements of impedance sensing and imaging are shown in this paper. Correlations between cell detection through optical microscopy and electrochemical impedance scanning were established.
Choi, Chang K; English, Anthony E; Kihm, Kenneth D; Margraves, Charles H
2007-01-01
This study quantifies the dynamic attachment and spreading of porcine pulmonary artery endothelial cells (PPAECs) on optically thin, indium tin oxide (ITO) biosensors using simultaneous differential interference contrast microscopy (DICM) and electrical microimpedance spectroscopy. A lock-in amplifier circuit monitored the impedance of PPAECs cultivated on the transparent ITO bioelectrodes as a function of frequency between 10 Hz and 100 kHz and as a function of time, while DICM images were simultaneously acquired. A digital image processing algorithm quantified the cell-covered electrode area as a function of time. The results of this study show that the fraction of the cell-covered electrode area is in qualitative agreement with the electrical impedance during the attachment phase following the cell settling on the electrode surface. The possibility of several distinctly different states of electrode coverage and cellular attachment giving rise to similar impedance signals is discussed.
Pressure transfer function of a JT15D nozzle due to acoustic and convected entropy fluctuations
NASA Astrophysics Data System (ADS)
Miles, J. H.
An acoustic transmission matrix analysis of sound propagation in a variable area duct with and without flow is extended to include convected entropy fluctuations. The boundary conditions used in the analysis are a transfer function relating entropy and pressure at the nozzle inlet and the nozzle exit impedance. The nozzle pressure transfer function calculated is compared with JT15D turbofan engine nozzle data. The one dimensional theory for sound propagation in a variable area nozzle with flow but without convected entropy is good at the low engine speeds where the nozzle exit Mach number is low (M=0.2) and the duct exit impedance model is good. The effect of convected entropy appears to be so negligible that it is obscured by the inaccuracy of the nozzle exit impedance model, the lack of information on the magnitude of the convected entropy and its phase relationship with the pressure, and the scatter in the data. An improved duct exit impedance model is required at the higher engine speeds where the nozzle exit Mach number is high (M=0.56) and at low frequencies (below 120 Hz).
Na, Wongi S.; Baek, Jongdae
2017-01-01
The emergence of composite materials has revolutionized the approach to building engineering structures. With the number of applications for composites increasing every day, maintaining structural integrity is of utmost importance. For composites, adhesive bonding is usually the preferred choice over the mechanical fastening method, and monitoring for delamination is an essential factor in the field of composite materials. In this study, a non-destructive method known as the electromechanical impedance method is used with an approach of monitoring multiple areas by specifying certain frequency ranges to correspond to a certain test specimen. Experiments are conducted using various numbers of stacks created by attaching glass fiber epoxy composite plates onto one another, and two different debonding damage types are introduced to evaluate the performance of the multiple monitoring electromechanical impedance method. PMID:28629194
Comparative Study of Impedance Eduction Methods, Part 2: NASA Tests and Methodology
NASA Technical Reports Server (NTRS)
Jones, Michael G.; Watson, Willie R.; Howerton, Brian M.; Busse-Gerstengarbe, Stefan
2013-01-01
A number of methods have been developed at NASA Langley Research Center for eduction of the acoustic impedance of sound-absorbing liners mounted in the wall of a flow duct. This investigation uses methods based on the Pridmore-Brown and convected Helmholtz equations to study the acoustic behavior of a single-layer, conventional liner fabricated by the German Aerospace Center and tested in the NASA Langley Grazing Flow Impedance Tube. Two key assumptions are explored in this portion of the investigation. First, a comparison of results achieved with uniform-flow and shear-flow impedance eduction methods is considered. Also, an approach based on the Prony method is used to extend these methods from single-mode to multi-mode implementations. Finally, a detailed investigation into the effects of harmonic distortion on the educed impedance is performed, and the results are used to develop guidelines regarding acceptable levels of harmonic distortion
NASA Astrophysics Data System (ADS)
Heimbach, Florian; Arndt, Alexander; Nettelbeck, Heidi; Langner, Frank; Giesen, Ulrich; Rabus, Hans; Sellner, Stefan; Toppari, Jussi; Shen, Boxuan; Baek, Woon Yong
2017-08-01
The ability of DNA to conduct electric current has been the topic of numerous investigations over the past few decades. Those investigations indicate that this ability is dependent on the molecular structure of the DNA. Radiation-induced damages, which lead to an alteration of the molecular structure, should therefore change the electrical impedance of a DNA molecule. In this paper, the damage due to ionising radiation is shown to have a direct effect on the electrical transport properties of DNA. Impedance measurements of DNA samples were carried out by an AC impedance spectrometer before, during and after irradiation. The samples comprised of DNA segments, which were immobilized between gold electrodes with a gap of 12 μm. The impedance of all DNA samples exhibited rising capacitive behaviour with increasing absorbed dose.
Complex Impedance of Fast Optical Transition Edge Sensors up to 30 MHz
NASA Astrophysics Data System (ADS)
Hattori, K.; Kobayashi, R.; Numata, T.; Inoue, S.; Fukuda, D.
2018-03-01
Optical transition edge sensors (TESs) are characterized by a very fast response, of the order of μs, which is 10^3 times faster than TESs for X-ray and gamma-ray. To extract important parameters associated with the optical TES, complex impedances at high frequencies (> 1 MHz) need to be measured, where the parasitic impedance in the circuit and reflections of electrical signals due to discontinuities in the characteristic impedance of the readout circuits become significant. This prevents the measurements of the current sensitivity β , which can be extracted from the complex impedance. In usual setups, it is hard to build a circuit model taking into account the parasitic impedances and reflections. In this study, we present an alternative method to estimate a transfer function without investigating the details of the entire circuit. Based on this method, the complex impedance up to 30 MHz was measured. The parameters were extracted from the impedance and were compared with other measurements. Using these parameters, we calculated the theoretical limit on an energy resolution and compared it with the measured energy resolution. In this paper, the reasons for the deviation of the measured value from theoretically predicted values will be discussed.
Kamada, Takahiro; Kaneko, Masahiro; Tomioka, Hiromi
2017-01-01
Forced oscillation technique (FOT) has been reported to be useful in the evaluation and management of obstructive lung disease, including COPD. To date, no data are available concerning long-term changes in respiratory system impedance measured by FOT. Additionally, although exacerbations have been reported to be associated with excessive lung function decline in COPD, the impact of exacerbations on the results of FOT has not been demonstrated. The aim of this study was to investigate the longitudinal changes in respiratory system impedance and the influence of exacerbations thereon. Between March 2011 and March 2012, outpatients who attended Kobe City Medical Center West Hospital with a diagnosis of COPD were assessed for eligibility. Baseline patient characteristics (age, sex, body mass index, smoking history, current smoking status, COPD stage), lung function (post-bronchodilator forced expiratory volume in 1 second [FEV 1 ]), blood tests (neutrophils and eosinophils), FOT, and COPD assessment test results were collected at enrollment. Lung function and FOT were examined every 6 months until March 2016. Annual changes in FEV 1 and FOT parameters were obtained from the slope of the linear regression curve. The patients were divided into 2 groups based on exacerbation history. Fifty-one of 58 patients with COPD were enrolled in this study. The median follow-up period was 57 (52-59) months. Twenty-five (49%) patients experienced exacerbations. A significant annual decline in FEV 1 and respiratory system impedance were shown. Additionally, annual changes in FEV 1 , respiratory system resistance at 5 Hz, respiratory system reactance at 5 Hz, and resonant frequency were greater in patients with exacerbations than in those without exacerbations. Exacerbations of COPD lead not only to a decline in lung function but also to an increase in respiratory system impedance.
Clinical application of an active electrode using an operational amplifier.
Nishimura, S; Tomita, Y; Horiuchi, T
1992-10-01
An active electrode (d10 mm, t6 mm) is presented, that functions as an impedance transformer (an input impedance > 10 G omega, an output impedance < 1 omega) by means of which we can derive surface EMG without any skin preparation and paste. This electrode was compared with a conventional one, and it was ascertained that the electrode could be replaced with the conventional one, and, moreover, it was preferable because it required less preparation time, and was less affected by environmental noise.
Willens, Scott; Cox, David M; Braue, Ernest H; Myers, Todd M; Wegner, Matthew D
2014-01-01
Telemetric monitoring of physiologic parameters in animal models is a critical component of chemical and biologic agent studies. The long-term collection of neurobehavioral and other physiologic data can require larger telemetry devices. Furthermore, such devices must be implanted in a location that is safe, well-tolerated, and functional. Göttingen minipigs (Sus scrofa domesticus) present an ideal large animal model for chemical agent studies due to their relatively small size, characterized health status, and ease of training and handling. We report an effective approach to implanting a novel device to measure transthoracic impedance to approximate respiratory tidal volume and rate in Suidae. We tested the approach using 24 male Göttingen minipigs. A ventral midline abdominal incision extending from the umbilicus to the prepuce was followed by a paramedian incision of the parietal peritoneum and dorsal blunt dissection to create a retroperitoneal pocket. The device was anchored inside the pocket to the internal abdominal musculature with 3-0 nonabsorbable suture, biopotential leads were routed through the abdominal musculature, and the pocket was closed with 3-0 absorbable suture. Paired biopotential leads were anchored intermuscularly at the level of the seventh rib midway between spine and sternum bilaterally to provide surrogate data for respiratory function. Postoperative recovery and gross pathology findings at necropsy were used to assess safety and refine the surgical procedure. Results demonstrated that this procedure permitted effective monitoring of complex physiologic data, including transthoracic impedance, without negatively affecting the health and behavior of the animals. PMID:25527027
Wu, Xiaoming; Dong, Xiuzhen; Qin, Mingxin; Fu, Feng; Wang, Yuemin; You, Fusheng; Xiang, Haiyan; Liu, Ruigang; Shi, Xuetao
2003-03-01
The in vivo measurements of rabbit brain tissue impedance were taken under both normal and ischemic conditions by using two-electrode measurement method in the frequency range from 0.1 Hz to 1 MHz. The dynamic images about the resistivity of cerebral ischemia were reconstructed based on a 16-electrode system. The results of in vivo measurement showed that the ratio of impedance increased can be as high as 75% at frequencies lower than 10 Hz. In the range from 1 KHz to 1 MHz, the ratio showed a constant value of 15%. The electrical impedance tomography (EIT) images obtained suggested that the regions of impedance changes highly correspond to the position of ischemia. It is confirmed that the brain function changes caused by local deficiency of blood can be detected and imaged by EIT method.
An approach to the diagnosis of metabolic syndrome by the multi-electrode impedance method
NASA Astrophysics Data System (ADS)
Furuya, N.; Sakamoto, K.; Kanai, H.
2010-04-01
It is well known that metabolic syndrome can induce myocardial infarction and cerebral infarction. So, it is very important to measure the visceral fat volume. In the electric impedance method, information in the vicinity of the electrodes is strongly reflected. Therefore, we propose a new multi-electrode arrangement method based on the impedance sensitivity theorem to measure the visceral fat volume. This electrode arrangement is designed to enable high impedance sensitivity in the visceral and subcutaneous fat regions. Currents are simultaneously applied to several current electrodes on the body surface, and one voltage electrode pair is arranged on the body surface near the organ of interest to obtain the visceral fat information and another voltage electrode pair is arranged on the body surface near the current electrodes to obtain the subcutaneous fat information. A simulation study indicates that by weighting the impedance sensitivity distribution, as in our method, a high-sensitivity region in the visceral and the subcutaneous fat regions can be formed. In addition, it was confirmed that the visceral fat volume can be estimated by the measured impedance data.
García-Sánchez, Tomás; Bragós, Ramon; Mir, Lluis M
2018-06-07
This paper reports the comparative analysis, by means of electric impedance spectroscopy measurements, of three different cell lines subjected to electroporative pulses. The multifrequency information is recorded simultaneously at 21 frequency values in the range between 5 kHz and 1.3 MHz using a multisine based measuring approach. The analysis of the pre-electroporation impedance spectra shows how the system is able to detect differences and similarities between the cell lines under analysis. Particularly, a good agreement is found between the average cell diameter and the characteristic frequency (the frequency corresponding to a maximum in the imaginary part of the impedance). The measurements performed during electroporation at three different electric field intensities show how the impedance spectra changes dynamically between the consecutive pulses of a train of 8,100 µs pulses delivered at 1 Hz repetition rate. There are clear differences between the changes in the impedance measured at low and high frequency. The multifrequency information has been fitted to an electrical equivalent model in order to understand the different contributions in the observed impedance changes (mainly separate between membrane permeabilization and the conductivity changes in the extracellular medium). Finally, a ratio of the low and high frequency impedance information is used to estimate the accumulated impedance decay and to compare it to the internalization of a fluorescent permeabilization reporter. The comparison between both techniques at the three electroporation electric field intensities assayed confirms the ability of impedance measurements to detect in a precise way the level of membrane permeabilization. Additionally, this study demonstrates how the real time information obtained thanks to impedance measurements can provide a more precise quantification of the membrane permeabilization extent. Copyright © 2018 Elsevier B.V. All rights reserved.
Mitigation of stress: new treatment alternatives.
Subhani, Ahmad Rauf; Kamel, Nidal; Mohamad Saad, Mohamad Naufal; Nandagopal, Nanda; Kang, Kenneth; Malik, Aamir Saeed
2018-02-01
Complaints of stress are common in modern life. Psychological stress is a major cause of lifestyle-related issues, contributing to poor quality of life. Chronic stress impedes brain function, causing impairment of many executive functions, including working memory, decision making and attentional control. The current study sought to describe newly developed stress mitigation techniques, and their influence on autonomic and endocrine functions. The literature search revealed that the most frequently studied technique for stress mitigation was biofeedback (BFB). However, evidence suggests that neurofeedback (NFB) and noninvasive brain stimulation (NIBS) could potentially provide appropriate approaches. We found that recent studies of BFB methods have typically used measures of heart rate variability, respiration and skin conductance. In contrast, studies of NFB methods have typically utilized neurocomputation techniques employing electroencephalography, functional magnetic resonance imaging and near infrared spectroscopy. NIBS studies have typically utilized transcranial direct current stimulation methods. Mitigation of stress is a challenging but important research target for improving quality of life.
Functional heartburn: definition and management strategies.
Zerbib, Frank; Bruley des Varannes, Stanislas; Simon, Mireille; Galmiche, Jean Paul
2012-06-01
Functional heartburn (FH) is a functional gastro-intestinal disorder characterized by symptoms of heartburn not related to gastro-esophageal reflux. The absence of evidence of reflux-related symptoms relies on absence of esophagitis at endoscopy (including biopsies to exclude eosinophilic esophagitis), a normal esophageal acid exposure during esophageal pH-monitoring together with a negative symptom-reflux association analysis and an unsatisfactory response to proton pump inhibitor therapy. Addition of impedance measurement to pH-monitoring is likely to increase the number of patients with recognized reflux-related symptoms. The pathophysiology of functional heartburn remains largely unknown but involves disturbed esophageal perception and psychological factors such as depression, anxiety and somatization. The treatment of FH remains largely empirical and an individual approach is therefore recommended. The clinician should provide reassurance and refrain from performing too many invasive tests or therapeutic procedures. The use of pain modulators is recommended by most experts despite the lack of appropriate clinical trials to support it.
Frequency response of electrochemical cells
NASA Technical Reports Server (NTRS)
Thomas, Daniel L.
1989-01-01
Impedance concepts can be applied to the analysis of battery electrodes, yielding information about the structure of the electrode and the processes occurring in the electrode. Structural parameters such as the specific area (surface area per gram of electrode) can be estimated. Electrode variables such as surface overpotential, ohmic losses, and diffusion limitations may be studied. Nickel and cadmium electrodes were studied by measuring the ac impedance as a function of frequency, and the specific areas that were determined were well within the range of specific areas determined from BET measurements. Impedance spectra were measured for the nickel and cadmium electrodes, and for a 20 A-hr NiCd battery as functions of the state of charge. More work is needed to determine the feasibility of using frequency response as a nondestructive testing technique for batteries.
Robust Magnetotelluric Impedance Estimation
NASA Astrophysics Data System (ADS)
Sutarno, D.
2010-12-01
Robust magnetotelluric (MT) response function estimators are now in standard use by the induction community. Properly devised and applied, these have ability to reduce the influence of unusual data (outliers). The estimators always yield impedance estimates which are better than the conventional least square (LS) estimation because the `real' MT data almost never satisfy the statistical assumptions of Gaussian distribution and stationary upon which normal spectral analysis is based. This paper discuses the development and application of robust estimation procedures which can be classified as M-estimators to MT data. Starting with the description of the estimators, special attention is addressed to the recent development of a bounded-influence robust estimation, including utilization of the Hilbert Transform (HT) operation on causal MT impedance functions. The resulting robust performances are illustrated using synthetic as well as real MT data.
Frazzoni, M; Conigliaro, R; Mirante, V G; Melotti, G
2012-02-01
By analysis of symptom-reflux association, endoscopy-negative refractory heartburn can be related to acid/non-acid refluxes with impedance-pH monitoring. Unfortunately, patients frequently do not report symptoms during the test. We aimed to assess the contribution of quantitative analysis of impedance-pH parameters added to symptom-reflux association in evaluating patients with endoscopy-negative heartburn refractory to high-dose proton pump inhibitor therapy. The symptom association probability (SAP), the symptom index (SI), the esophageal acid exposure time and the number of distal and proximal refluxes were assessed at on-therapy impedance-pH monitoring. Relationships with hiatal hernia and manometric findings were also evaluated. Eighty patients were prospectively studied. Refractory heartburn was more frequently related to reflux by a positive SAP/SI and/or abnormal impedance-pH parameters (52/80 cases) (65%) than by a positive SAP/SI only (38/80 cases) (47%) (P = 0.038). In patients with refractory non-erosive reflux disease (NERD) defined by a positive SAP/SI and/or abnormal impedance-pH parameters, the prevalence of hiatal hernia was significantly higher (56%vs 21%, P = 0.007) and the mean lower esophageal sphincter tone was significantly lower (18.7 vs 25.8 mmHg, P = 0.005) than in those (35%) with reflux-unrelated, i.e., functional heartburn (FH). On the contrary, no significant difference was observed subdividing patients according to a positive SAP/SI only. Quantitative analysis of impedance-pH parameters added to symptom-reflux association allows a subdivision of refractory-heartburn patients into refractory NERD and FH which is substantiated by pathophysiological findings and which restricts the diagnosis of FH to one third of cases. © 2011 Blackwell Publishing Ltd.
NASA Astrophysics Data System (ADS)
Hao Jiang, Zhi; Werner, Douglas H.
2013-12-01
In this paper, we report an approach for achieving near-perfect low-profile electromagnetic cloaking beyond the quasi-static limit. In contrast to previous works on metasurface cloaks where only the Leontovich surface impedance boundary condition has been considered, we employ a second-order surface impedance boundary condition to account for the radial response of the proposed anisotropic metasurfaces. This radial surface polarizability tensor parameter can be tailored to eliminate the higher order scattering modes. It is shown from analytical expressions that for a moderate-sized perfect electric conducting or dielectric cylinder (∼0.4λ0 in width), near-perfect scattering reduction, i.e. >98%, can be achieved by a single anisotropic metasurface with non-vanishing radial response, which is far superior to the conventional scalar impedance surface. A practical design of the metasurface is also presented and further validated by full-wave simulations. The physical mechanism of the metasurface cloaks is investigated in detail, revealing that the radiation cancellation of the induced surface currents is responsible for the scattering reduction. Importantly, it is shown that in addition to a ‘low-visibility coating’, the metasurface also functions to provide induced current enhancement which would be beneficial for the operation of a ‘cloaked sensor’. These findings will broaden the usage of metasurfaces to applications ranging from scattering reduction to noninvasive probing for objects beyond the quasi-static limit.
Modeling of a carbon nanotube ultracapacitor.
Orphanou, Antonis; Yamada, Toshishige; Yang, Cary Y
2012-03-09
The modeling of carbon nanotube ultracapacitor (CNU) performance based on the simulation of electrolyte ion motion between the cathode and the anode is described. Using a molecular dynamics (MD) approach, the equilibrium positions of the electrode charges interacting through the Coulomb potential are determined, which in turn yield the equipotential surface and electric field associated with the capacitor. With an applied ac voltage, the current is computed based on the nanotube and electrolyte particle distribution and interaction, resulting in the frequency-dependent impedance Z(ω). From the current and impedance profiles, the Nyquist and cyclic voltammetry (CV) plots are then extracted. The results of these calculations compare well with existing experimental data. A lumped-element equivalent circuit for the CNU is proposed and the impedance computed from this circuit correlates well with the simulated and measured impedances.
Guang, Hui; Ji, Linhong; Shi, Yingying; Misgeld, Berno J E
2018-01-01
The robot-assisted therapy has been demonstrated to be effective in the improvements of limb function and even activities of daily living for patients after stroke. This paper presents an interactive upper-limb rehabilitation robot with a parallel mechanism and an isometric screen embedded in the platform to display trajectories. In the dynamic modeling for impedance control, the effects of friction and inertia are reduced by introducing the principle of virtual work and derivative of Jacobian matrix. To achieve the assist-as-needed impedance control for arbitrary trajectories, the strategy based on orthogonal deviations is proposed. Simulations and experiments were performed to validate the dynamic modeling and impedance control. Besides, to investigate the influence of the impedance in practice, a subject participated in experiments and performed two types of movements with the robot, that is, rectilinear and circular movements, under four conditions, that is, with/without resistance or impedance, respectively. The results showed that the impedance and resistance affected both mean absolute error and standard deviation of movements and also demonstrated the significant differences between movements with/without impedance and resistance ( p < 0.001). Furthermore, the error patterns were discussed, which suggested that the impedance environment was capable of alleviating movement deviations by compensating the synergetic inadequacy between the shoulder and elbow joints.
Shi, Yingying; Misgeld, Berno J. E.
2018-01-01
The robot-assisted therapy has been demonstrated to be effective in the improvements of limb function and even activities of daily living for patients after stroke. This paper presents an interactive upper-limb rehabilitation robot with a parallel mechanism and an isometric screen embedded in the platform to display trajectories. In the dynamic modeling for impedance control, the effects of friction and inertia are reduced by introducing the principle of virtual work and derivative of Jacobian matrix. To achieve the assist-as-needed impedance control for arbitrary trajectories, the strategy based on orthogonal deviations is proposed. Simulations and experiments were performed to validate the dynamic modeling and impedance control. Besides, to investigate the influence of the impedance in practice, a subject participated in experiments and performed two types of movements with the robot, that is, rectilinear and circular movements, under four conditions, that is, with/without resistance or impedance, respectively. The results showed that the impedance and resistance affected both mean absolute error and standard deviation of movements and also demonstrated the significant differences between movements with/without impedance and resistance (p < 0.001). Furthermore, the error patterns were discussed, which suggested that the impedance environment was capable of alleviating movement deviations by compensating the synergetic inadequacy between the shoulder and elbow joints. PMID:29850004
Monitoring and Characterizing Crop Root Systems Using Electrical Impedance Tomography (EIT)
NASA Astrophysics Data System (ADS)
Weigand, M.; Kemna, A.
2016-12-01
A better understanding of root-soil interactions and associated processes is essential to achieve progress in crop breeding and management, prompting the need for high-resolution and non-destructive characterization methods. Such methods are still lacking, in particular for characterizing root growth and function in the field. A promising technique in this respect is electrical impedance tomography (EIT), which provides images of the low-frequency electrical conduction and polarization properties and thus can be used to investigate polarization processes occurring within and in the direct vicinity of roots under the influence of an external alternating electric field. This approach takes advantage of the well-known polarization properties associated with electrical double layers forming at membranes of cells and cell clusters. However, upscaling these processes to the scale of an impedance, or complex conductivity, spectrum of the whole root system is not trivial given the lack of electrical root models, the complexity of root systems, and the occurrence of additional larger-scale, ion-selective, and therefore polarizable, structures such as the Casparian strip. We here present results from several EIT laboratory studies on rhizotrons with crop root systems in aqueous solutions. Based on optimized experimental and data analysis procedures, enabling the imaging of the weak signals encountered in our studies, we found systematic spatial and temporal changes of both the magnitude and the shape of the spectral polarization signatures during nutrient deprivation and in response to the decapitation of plants. Consistent, but relatively weak, spectral impedance changes were also observed over diurnal cycles. Our results provide evidence for the capability of EIT to non-invasively image and monitor root systems at the rhizotron scale. They further suggest that EIT is a promising tool for imaging, characterizing, and monitoring crop roots at the field scale.
Measurement of Young’s Modulus and Internal Damping of Pork Muscle in Dynamic Mode
NASA Astrophysics Data System (ADS)
Chakroun, Moez; Ghozlen, Med Hédi Ben
2016-09-01
Automotive shocks involve various tiers’ speed for different human body tissues. Knowing the behavior of these tissues, including muscles, in different vibration frequency is therefore necessary. The muscle has viscoelatic properties. Dynamically, this material has variable mechanical properties depending on the vibration frequency. A novel technique is being employed to examine the variation of the mechanical impedance of pork muscle as a function of frequency. A force is imposed on the lower surface of the sample and acceleration is measured on its upper surface. These two parameters are measured using sensors. The sample is modeled by Kelvin-Voigt model. These measures allow deducing the change in the mechanical impedance modulus (/Zexp/ = /Force: Acceleration/) of pork muscle as a function of vibration frequency. The measured impedance has a resonance of approximately 60Hz. Best-fit parameters of theoretical impedance can be deduced by superposition with the experiment result. The variation of Young’s modulus and internal damping of pig’s muscle as a function of frequency are determined. The results obtained between 5Hz and 30Hz are the same as determined by Aimedieu and al in 2003, therefore validating our technique. The Young’s modulus of muscle increases with the frequency, on the other hand, we note a rating decrease of internal damping.
Stoecklin, S; Volk, T; Yousaf, A; Reindl, L
2015-01-01
In this paper, an enhanced approach of a class E amplifier being insensitive to coil impedance variations is presented. While state of the art class E amplifiers widely being used to supply implanted systems show a strong degradation of efficiency when powering distance, coil orientation or the implant current consumption deviate from the nominal design, the presented concept is able to detect these deviations on-line and to reconfigure the amplifier automatically. The concept is facilitated by a new approach of sensing the load impedance without interruption of the power supply to the implant, while the main components of the class E amplifier are programmable by software. Therefore, the device is able to perform dynamic impedance matching. Besides presenting the operational principle and the design equations, we show an adaptive prototype reader system which achieves a drain efficiency of up to 92% for a wide range of reflected coil impedances from 1 to 40 Ω. The integrated communication concept allows downlink data rates of up to 500 kBit/s, while the load modulation based uplink from implant to reader was verified of providing up to 1.35 MBit/s.
Langley, Robin S; Cotoni, Vincent
2010-04-01
Large sections of many types of engineering construction can be considered to constitute a two-dimensional periodic structure, with examples ranging from an orthogonally stiffened shell to a honeycomb sandwich panel. In this paper, a method is presented for computing the boundary (or edge) impedance of a semi-infinite two-dimensional periodic structure, a quantity which is referred to as the direct field boundary impedance matrix. This terminology arises from the fact that none of the waves generated at the boundary (the direct field) are reflected back to the boundary in a semi-infinite system. The direct field impedance matrix can be used to calculate elastic wave transmission coefficients, and also to calculate the coupling loss factors (CLFs), which are required by the statistical energy analysis (SEA) approach to predicting high frequency vibration levels in built-up systems. The calculation of the relevant CLFs enables a two-dimensional periodic region of a structure to be modeled very efficiently as a single subsystem within SEA, and also within related methods, such as a recently developed hybrid approach, which couples the finite element method with SEA. The analysis is illustrated by various numerical examples involving stiffened plate structures.
NASA Technical Reports Server (NTRS)
Dean, P. D.
1978-01-01
A systems concept procedure is described for the optimization of acoustic duct liner design for both uniform and multisegment types. The concept was implemented by the use of a double reverberant chamber flow duct facility coupled with sophisticated computer control and acoustic analysis systems. The optimization procedure for liner insertion loss was based on the concept of variable liner impedance produced by bias air flow through a multilayer, resonant cavity liner. A multiple microphone technique for in situ wall impedance measurements was used and successfully adapted to produce automated measurements for all liner configurations tested. The complete validation of the systems concept was prevented by the inability to optimize the insertion loss using bias flow induced wall impedance changes. This inability appeared to be a direct function of the presence of a higher order energy carrying modes which were not influenced significantly by the wall impedance changes.
Ion transport restriction in mechanically strained separator membranes
NASA Astrophysics Data System (ADS)
Cannarella, John; Arnold, Craig B.
2013-03-01
We use AC impedance methods to investigate the effect of mechanical deformation on ion transport in commercial separator membranes and lithium-ion cells as a whole. A Bruggeman type power law relationship is found to provide an accurate correlation between porosity and tortuosity of deformed separators, which allows the impedance of a separator membrane to be predicted as a function of deformation. By using mechanical compression to vary the porosity of the separator membranes during impedance measurements it is possible to determine both the α and γ parameters from the modified Bruggeman relation for individual separator membranes. From impedance testing of compressed pouch cells it is found that separator deformation accounts for the majority of the transport restrictions arising from compressive stress in a lithium-ion cell. Finally, a charge state dependent increase in the impedance associated with charge transfer is observed with increasing cell compression.
Ehmler, Hartmut; Köppen, Matthias
2007-10-01
The impedance spectrum test was employed for detection of short circuits within Wendelstein 7-X (W7-X) superconducting magnetic field coils. This test is based on measuring the complex impedance over several decades of frequency. The results are compared to predictions of appropriate electrical equivalent circuits of coils in different production states or during cold test. When the equivalent circuit is not too complicated the impedance can be represented by an analytic function. A more detailed analysis is performed with a network simulation code. The overall agreement of measured and calculated or simulated spectra is good. Two types of short circuits which appeared are presented and analyzed. The detection limit of the method is discussed. It is concluded that combined high-voltage ac and low-voltage impedance spectrum tests are ideal means to rule out short circuits in the W7-X coils.
Kinetic damping in the spectra of the spherical impedance probe
NASA Astrophysics Data System (ADS)
Oberrath, J.
2018-04-01
The impedance probe is a measurement device to measure plasma parameters, such as electron density. It consists of one electrode connected to a network analyzer via a coaxial cable and is immersed into a plasma. A bias potential superposed with an alternating potential is applied to the electrode and the response of the plasma is measured. Its dynamical interaction with the plasma in an electrostatic, kinetic description can be modeled in an abstract notation based on functional analytic methods. These methods provide the opportunity to derive a general solution, which is given as the response function of the probe–plasma system. It is defined by the matrix elements of the resolvent of an appropriate dynamical operator. Based on the general solution, a residual damping for vanishing pressure can be predicted and can only be explained by kinetic effects. In this paper, an explicit response function of the spherical impedance probe is derived. Therefore, the resolvent is determined by its algebraic representation based on an expansion in orthogonal basis functions. This allows one to compute an approximated response function and its corresponding spectra. These spectra show additional damping due to kinetic effects and are in good agreement with former kinetically determined spectra.
Cho, Yu Kyung; Choi, Myung-Gyu; Park, Jae Myung; Oh, Jung Hwan; Paik, Chang Nyol; Lee, Joon Wook; Lee, In Seok; Kim, Sang Woo; Chung, In-Sik
2006-10-21
To evaluate the functional aspect of esophageal motility in healthy subjects and in patients who were referred for esophageal function testing using multichannel intraluminal impedance-esophageal manometry (MII-EM), and to assess the clinical utility of MII-EM. From September 2003 to January 2004, we performed the MII-EM on healthy volunteers and all the patients who were referred for esophageal function testing. Each patient received 10 liquid and 10 viscous swallows. We analyzed the results, the impedance and the manometric findings. Some of the subjects had additional ambulatory 24-h pH study performed to diagnose gastroesophageal reflux disease (GERD). Among 89 studied subjects, the MII-EM findings showed normal esophageal motility in 50 (56.17%), ineffective esophageal motility (IEM) in 17 (19.10%), nutcracker esophagus in 7 (7.86%), achalasia in 4 (4.49%), and scleroderma esophagus in 11 (12.35%) cases. The completeness and the speed of bolus transit were in the order of nutcracker esophagus, normal manometry and IEM. Some of the swallows showing normal manometry and IEM had incomplete transit. In the achalasia and scleroderma esophagus, almost all the swallows had incomplete transit. The body amplitudes were higher for the swallows with complete transit than for the swallows with incomplete transit. There was not a significant difference in the manometric and impedance findings between the subjects with and without GERD. MII-EM is a useful tool in assessing the esophageal function in the patients having esophageal motility abnormality. The primary factors influencing the bolus transit are the amplitude of the esophageal body and normal peristalsis.
LONGITUDINAL IMPEDANCE OF THE SQUID GIANT AXON
Cole, Kenneth S.; Baker, Richard F.
1941-01-01
Longitudinal alternating current impedance measurements have been made on the squid giant axon over the frequency range from 30 cycles per second to 200 kc. per second. Large sea water electrodes were used and the inter-electrode length was immersed in oil. The impedance at high frequency was approximately as predicted theoretically on the basis of the poorly conducting dielectric characteristics of the membrane previously determined. For the large majority of the axons, the impedance reached a maximum at a low frequency and the reactance then vanished at a frequency between 150 and 300 cycles per second. Below this frequency, the reactance was inductive, reaching a maximum and then approaching zero as the frequency was decreased. The inductive reactance is a property of the axon and requires that it contain an inductive structure. The variation of the impedance with interpolar distance indicates that the inductance is in the membrane. The impedance characteristics of the membrane as calculated from the measured longitudinal impedance of the axon may be expressed by an equivalent membrane circuit containing inductance, capacity, and resistance. For a square centimeter of membrane the capacity of 1 µf with dielectric loss is shunted by the series combination of a resistance of 400 ohms and an inductance of one-fifth henry. PMID:19873252
Parametric investigation of enclosed keeper discharge characteristics
NASA Technical Reports Server (NTRS)
Sheheen, T. W.; Finke, R. C.
1973-01-01
Volt-ampere discharge characteristics of an enclosed keeper hollow cathode discharge were measured as a function of the mercury flow rate and external circuit impedance. Discharge currents were varied from 0 to 1 ampere and voltages were 7 to 39 volts. Batteries and a vacuum tube control circuit were used to obtain characteristics curves that were independent of power supply impedance. Variation of the neutral flow results in changes in the discharge which interact with the impedance of the external circuit, and under some conditions, give rise to multiple operating points.
Matching technique yields optimum LNA performance. [Low Noise Amplifiers
NASA Technical Reports Server (NTRS)
Sifri, J. D.
1986-01-01
The present article is concerned with a case in which an optimum noise figure and unconditional stability have been designed into a 2.385-GHz low-noise preamplifier via an unusual method for matching the input with a suspended line. The results obtained with several conventional line-matching techniques were not satisfactory. Attention is given to the minimization of thermal noise, the design procedure, requirements for a high-impedance line, a sampling of four matching networks, the noise figure of the single-line matching network as a function of frequency, and the approaches used to achieve unconditional stability.
Fan, Xu; Wang, Yunguang; Cheng, Haiping; Chong, Xiaochen
2016-02-01
The present circuit was designed to apply to human tissue impedance tuning and matching device in ultra-short wave treatment equipment. In order to judge if the optimum status of circuit parameter between energy emitter circuit and accepter circuit is in well syntony, we designed a high frequency envelope detect circuit to coordinate with automatic adjust device of accepter circuit, which would achieve the function of human tissue impedance matching and tuning. Using the sampling coil to receive the signal of amplitude-modulated wave, we compared the voltage signal of envelope detect circuit with electric current of energy emitter circuit. The result of experimental study was that the signal, which was transformed by the envelope detect circuit, was stable and could be recognized by low speed Analog to Digital Converter (ADC) and was proportional to the electric current signal of energy emitter circuit. It could be concluded that the voltage, transformed by envelope detect circuit can mirror the real circuit state of syntony and realize the function of human tissue impedance collecting.
Impedance properties of circular microstrip antenna
NASA Technical Reports Server (NTRS)
Deshpande, M. D.; Bailey, M. C.
1983-01-01
A moment method solution to the input impedance of a circular microstrip antenna excited by either a microstrip feed or a coaxial probe is presented. Using the exact dyadic Green's function and the Fourier transform the problem is formulated in terms of Richmond's reaction integral equation from which the unknown patch current can be solved for. The patch current is expanded in terms of regular surface patch modes and an attachment mode (for probe excited case) which insures continuity of the current at probe/patch junction, proper polarization and p-dependance of patch current in the vicinity of the probe. The input impedance of a circular microstrip antenna is computed and compared with earlier results. Effect of attachment mode on the input impedance is also discussed.
Woodland, Philip; Al-Zinaty, Mohannad; Yazaki, Etsuro; Sifrim, Daniel
2013-09-01
Patients with non-erosive reflux disease (NERD) have impaired oesophageal mucosal integrity (dilated intercellular spaces). Oesophageal mucosal integrity reflects the balance between repeated reflux damage and mucosal recovery. The relationship between mucosal integrity and acid sensitivity is unclear. Oesophageal impedance may be used for in vivo mucosal integrity measurement. We studied acid-induced changes in oesophageal mucosal integrity and acid perception in patients with heartburn. 50 patients with heartburn whithout oesophagitis underwent impedance monitoring before, during and after 10 min oesophageal perfusion with neutral (pH 6.5) and acid solutions (pH 1). Symptoms and impedance were recorded during perfusion. Impedance recovery was assessed for 2 h post-perfusion in ambulatory conditions followed by 24-h impedance-pH study. Reflux monitoring discriminated 20 NERD and 30 functional heartburn (FH) patients. Neutral perfusion caused impedance fall that recovered within 10 min. Acid perfusion caused impedance fall with slow recovery: 6.5 Ω/min (IQR 3.3-12.0 Ω/min). Patients with slow recovery (< 25th percentile) had lower baseline impedance (1273 Ω ± 208 Ω vs. 3220 Ω ± 275 Ω ±, p < 0.01) and more frequent acid sensitivity (10/12 vs. 4/12, p = 0.04) than those with fast (> 75th percentile) recovery. Patients with NERD had lower baseline impedance (1669 ± 182 Ω vs. 2384 ± 211 Ω, p = 0.02) and slower impedance recovery (6.0 ± 0.9 Ω/min vs. 10.7 ± 1.6 Ω/min, p = 0.03) than patients with FH. Impaired mucosal integrity might be the consequence of repeated reflux episodes with slow recovery. Mucosal integrity, recovery capacity and symptom perception are linked. Low basal impedance and slow recovery after acid challenge are associated with increased acid sensitivity.
NASA Astrophysics Data System (ADS)
Mahara, Aditya; Khan, Shadab; Schned, Alan R.; Hyams, Elias S.; Halter, Ryan J.
2015-03-01
Positive surgical margins (PSMs) found following prostate cancer surgery are a significant risk factor for post-operative disease recurrence. Noxious adjuvant radiation and chemical-based therapies are typically offered to men with PSMs. Unfortunately, no real-time intraoperative technology is currently available to guide surgeons to regions of suspicion during the initial prostatectomy where immediate surgical excisions could be used to reduce the chance of PSMs. A microendoscopic electrical impedance sensing probe was developed with the intention of providing real-time feedback regarding margin status to surgeons during robot-assisted laparoscopic prostatectomy (RALP) procedures. A radially configured 17-electrode microendoscopic probe was designed, constructed, and initially evaluated through use of gelatin-based phantoms and an ex vivo human prostate specimen. Impedance measurements are recorded at 10 frequencies (10 kHz - 100 kHz) using a high-speed FPGA-based electrical impedance tomography (EIT) system. Tetrapolar impedances are recorded from a number of different electrode configurations strategically chosen to sense tissue in a pre-defined sector underlying the probe face. A circular electrical impedance map (EIM) with several color-coded pie-shaped sectors is created to represent the impedance values of the probed tissue. Gelatin phantom experiments show an obvious distinction in the impedance maps between high and low impedance regions. Similarly, the EIM generated from the ex vivo prostate case shows distinguishing features between cancerous and benign regions. Based on successful development of this probe and these promising initial results, EIMs of additional prostate specimens are being collected to further evaluate this approach for intraoperative surgical margin assessment during RALP procedures.
Comparative Study of Impedance Eduction Methods. Part 1; DLR Tests and Methodology
NASA Technical Reports Server (NTRS)
Busse-Gerstengarbe, Stefan; Bake, Friedrich; Enghardt, Lars; Jones, Michael G.
2013-01-01
The absorption efficiency of acoustic liners used in aircraft engines is characterized by the acoustic impedance. World wide, many grazing ow test rigs and eduction methods are available that provide values for that impedance. However, a direct comparison and assessment of the data of the di erent rigs and methods is often not possible because test objects and test conditions are quite di erent. Only a few papers provide a direct comparison. Therefore, this paper together with a companion paper, present data measured with a reference test object under similar conditions in the DLR and NASA grazing ow test rigs. Additionally, by applying the in-house methods Liner Impedance Non-Uniform ow Solving algorithm (LINUS, DLR) and Convected Helmhholtz Equation approach (CHE, NASA) on the data sets, similarities and differences due to underlying theory are identi ed and discussed.
A Powered Prosthetic Intervention for Bilateral Transfemoral Amputees
Lawson, Brian E.; Ruhe, Brian; Shultz, Amanda; Goldfarb, Michael
2014-01-01
This paper presents the design and validation of a control system for a pair of powered knee and ankle prostheses to be used as a prosthetic intervention for bilateral transfemoral amputees. The control system leverages communication between the prostheses for enhanced awareness and stability, along with power generation at the knee and ankle joints to better restore biomechanical functionality in level ground walking. The control methodology employed is a combination of an impedance-based framework for weight-bearing portions of gait and a trajectory-based approach for the non-weight-bearing portions. The control system was implemented on a pair of self-contained powered knee and ankle prostheses, and the ability of the prostheses and control approach to provide walking functionality was assessed in a set of experimental trials with a bilateral transfemoral amputee subject. Specifically, experimental data from these trials indicate that the powered prostheses and bilateral control architecture provide gait kinematics that reproduce healthy gait kinematics to a greater extent than the subject’s daily-use passive prostheses. PMID:25014950
A Multi-Level Decision Fusion Strategy for Condition Based Maintenance of Composite Structures
Sharif Khodaei, Zahra; Aliabadi, M.H.
2016-01-01
In this work, a multi-level decision fusion strategy is proposed which weighs the Value of Information (VoI) against the intended functions of a Structural Health Monitoring (SHM) system. This paper presents a multi-level approach for three different maintenance strategies in which the performance of the SHM systems is evaluated against its intended functions. Level 1 diagnosis results in damage existence with minimum sensors covering a large area by finding the maximum energy difference for the guided waves propagating in pristine structure and the post-impact state; Level 2 diagnosis provides damage detection and approximate localization using an approach based on Electro-Mechanical Impedance (EMI) measures, while Level 3 characterizes damage (exact location and size) in addition to its detection by utilising a Weighted Energy Arrival Method (WEAM). The proposed multi-level strategy is verified and validated experimentally by detection of Barely Visible Impact Damage (BVID) on a curved composite fuselage panel. PMID:28773910
Multivariable Dynamic Ankle Mechanical Impedance With Relaxed Muscles
Lee, Hyunglae; Krebs, Hermano Igo; Hogan, Neville
2015-01-01
Neurological or biomechanical disorders may distort ankle mechanical impedance and thereby impair locomotor function. This paper presents a quantitative characterization of multivariable ankle mechanical impedance of young healthy subjects when their muscles were relaxed, to serve as a baseline to compare with pathophysiological ankle properties of biomechanically and/or neurologically impaired patients. Measurements using a highly backdrivable wearable ankle robot combined with multi-input multi-output stochastic system identification methods enabled reliable characterization of ankle mechanical impedance in two degrees-of-freedom (DOFs) simultaneously, the sagittal and frontal planes. The characterization included important ankle properties unavailable from single DOF studies: coupling between DOFs and anisotropy as a function of frequency. Ankle impedance in joint coordinates showed responses largely consistent with a second-order system consisting of inertia, viscosity, and stiffness in both seated (knee flexed) and standing (knee straightened) postures. Stiffness in the sagittal plane was greater than in the frontal plane and furthermore, was greater when standing than when seated, most likely due to the stretch of bi-articular muscles (medial and lateral gastrocnemius). Very low off-diagonal partial coherences implied negligible coupling between dorsiflexion-plantarflexion and inversion-eversion. The directions of principal axes were tilted slightly counterclockwise from the original joint coordinates. The directional variation (anisotropy) of ankle impedance in the 2-D space formed by rotations in the sagittal and frontal planes exhibited a characteristic “peanut” shape, weak in inversion-eversion over a wide range of frequencies from the stiffness dominated region up to the inertia dominated region. Implications for the assessment of neurological and biomechanical impairments are discussed. PMID:24686292
Multivariable dynamic ankle mechanical impedance with relaxed muscles.
Lee, Hyunglae; Krebs, Hermano Igo; Hogan, Neville
2014-11-01
Neurological or biomechanical disorders may distort ankle mechanical impedance and thereby impair locomotor function. This paper presents a quantitative characterization of multivariable ankle mechanical impedance of young healthy subjects when their muscles were relaxed, to serve as a baseline to compare with pathophysiological ankle properties of biomechanically and/or neurologically impaired patients. Measurements using a highly backdrivable wearable ankle robot combined with multi-input multi-output stochastic system identification methods enabled reliable characterization of ankle mechanical impedance in two degrees-of-freedom (DOFs) simultaneously, the sagittal and frontal planes. The characterization included important ankle properties unavailable from single DOF studies: coupling between DOFs and anisotropy as a function of frequency. Ankle impedance in joint coordinates showed responses largely consistent with a second-order system consisting of inertia, viscosity, and stiffness in both seated (knee flexed) and standing (knee straightened) postures. Stiffness in the sagittal plane was greater than in the frontal plane and furthermore, was greater when standing than when seated, most likely due to the stretch of bi-articular muscles (medial and lateral gastrocnemius). Very low off-diagonal partial coherences implied negligible coupling between dorsiflexion-plantarflexion and inversion-eversion. The directions of principal axes were tilted slightly counterclockwise from the original joint coordinates. The directional variation (anisotropy) of ankle impedance in the 2-D space formed by rotations in the sagittal and frontal planes exhibited a characteristic "peanut" shape, weak in inversion-eversion over a wide range of frequencies from the stiffness dominated region up to the inertia dominated region. Implications for the assessment of neurological and biomechanical impairments are discussed.
Mapping Earth's electromagnetic dimensionality
NASA Astrophysics Data System (ADS)
Love, J. J.; Kelbert, A.; Bedrosian, P.
2017-12-01
The form of a magnetotelluric impedance tensor, obtained for a given geographic site through simultaneous measurement of geomagnetic and geoelectric field variation, is affected by electrical conductivity structure beneath the measurement site. Building on existing methods for characterizing the symmetry of magnetotelluric impedance tensors, a simple scalar measure is developed for measuring the (frequency dependent) proportion of the impedance tensor that is not just a one-dimensional (1D) function of depth ("non-1D-ness"). These measures are applied to nearly 1000 impedance tensors obtained during magnetotelluric surveys, those for the continental United States and obtained principally through the National Science Foundation's EarthScope project. Across geomagnetic/geoelectric variational periods ranging from 30 s to 3,000 s, corresponding to crustal and upper mantle depths, it is shown that local Earth structure is very often not simply 1D-depth-dependent - often less than 50% of magnetotelluric impedance is 1D. For selected variational frequencies, non-1D-ness is mapped and the relationship between electromagnetic dimensionality and known geological and tectonic structures is discussed. The importance of using realistic surface impedances to accurately evaluate magnetic-storm geoelectric hazards is emphasized.
An efficient signal processing tool for impedance-based structural health monitoring
NASA Astrophysics Data System (ADS)
O'Brien, Megan K.; Taylor, Stuart G.; Farinholt, Kevin M.; Park, Gyuhae; Farrar, Charles R.
2009-03-01
Various experimental studies have demonstrated that an impedance-based approach to structural health monitoring can be an effective means of damage detection. Using the self-sensing and active-sensing capabilities of piezoelectric materials, the electromechanical impedance response can be monitored to provide a qualitative indication of the overall health of a structure. Although impedance analyzers are commonly used to collect such data, they are bulky and impractical for long-term field implementation, so a smaller and more portable device is desired. However, impedance measurements often contain a sizeable number of data points, and a smaller device may not possess enough memory to store the required information, particularly for real-time analysis. Therefore, the amount of data used to assess the integrity of a structure must be significantly reduced. A new type of cross correlation analysis, for which impedance data is instantaneously correlated between different sensor sets and different frequency ranges, as opposed to be correlated to pre-stored baseline data, is proposed to drastically reduce the amount of data to a single correlation coefficient and provide a quantitative means of detecting damage relative to the sensor positions. The proposed analysis is carried out on a 3-story representative structure and its efficiency is demonstrated.
Integrated circuits and electrode interfaces for noninvasive physiological monitoring.
Ha, Sohmyung; Kim, Chul; Chi, Yu M; Akinin, Abraham; Maier, Christoph; Ueno, Akinori; Cauwenberghs, Gert
2014-05-01
This paper presents an overview of the fundamentals and state of the-art in noninvasive physiological monitoring instrumentation with a focus on electrode and optrode interfaces to the body, and micropower-integrated circuit design for unobtrusive wearable applications. Since the electrode/optrode-body interface is a performance limiting factor in noninvasive monitoring systems, practical interface configurations are offered for biopotential acquisition, electrode-tissue impedance measurement, and optical biosignal sensing. A systematic approach to instrumentation amplifier (IA) design using CMOS transistors operating in weak inversion is shown to offer high energy and noise efficiency. Practical methodologies to obviate 1/f noise, counteract electrode offset drift, improve common-mode rejection ratio, and obtain subhertz high-pass cutoff are illustrated with a survey of the state-of-the-art IAs. Furthermore, fundamental principles and state-of-the-art technologies for electrode-tissue impedance measurement, photoplethysmography, functional near-infrared spectroscopy, and signal coding and quantization are reviewed, with additional guidelines for overall power management including wireless transmission. Examples are presented of practical dry-contact and noncontact cardiac, respiratory, muscle and brain monitoring systems, and their clinical applications.
Impedance spectroscopy for the detection and identification of unknown toxins
NASA Astrophysics Data System (ADS)
Riggs, B. C.; Plopper, G. E.; Paluh, J. L.; Phamduy, T. B.; Corr, D. T.; Chrisey, D. B.
2012-06-01
Advancements in biological and chemical warfare has allowed for the creation of novel toxins necessitating a universal, real-time sensor. We have used a function-based biosensor employing impedance spectroscopy using a low current density AC signal over a range of frequencies (62.5 Hz-64 kHz) to measure the electrical impedance of a confluent epithelial cell monolayer at 120 sec intervals. Madin Darby canine kidney (MDCK) epithelial cells were grown to confluence on thin film interdigitated gold electrodes. A stable impedance measurement of 2200 Ω was found after 24 hrs of growth. After exposure to cytotoxins anthrax lethal toxin and etoposide, the impedance decreased in a linear fashion resulting in a 50% drop in impedance over 50hrs showing significant difference from the control sample (~20% decrease). Immunofluorescent imaging showed that apoptosis was induced through the addition of toxins. Similarities of the impedance signal shows that the mechanism of cellular death was the same between ALT and etoposide. A revised equivalent circuit model was employed in order to quantify morphological changes in the cell monolayer such as tight junction integrity and cell surface area coverage. This model showed a faster response to cytotoxin (2 hrs) compared to raw measurements (20 hrs). We demonstrate that herein that impedance spectroscopy of epithelial monolayers serves as a real-time non-destructive sensor for unknown pathogens.
Variable Cadence Walking and Ground Adaptive Standing with a Powered Ankle Prosthesis
Shultz, Amanda H.; Lawson, Brian E.; Goldfarb, Michael
2015-01-01
Abstract This paper describes a control approach that provides walking and standing functionality for a powered ankle prosthesis, and demonstrates the efficacy of the approach in experiments in which a unilateral transtibial amputee subject walks with the prosthesis at variable cadences, and stands on various slopes. Both controllers incorporate a finite-state structure that emulates healthy ankle joint behavior via a series of piecewise passive impedance functions. The walking controller incorporates an algorithm to modify impedance parameters based on estimated cadence, while the standing controller incorporates an algorithm to modulate the ankle equilibrium angle in order to adapt to the ground slope and user posture, and the supervisory controller selects between the walking and standing controllers. The system is shown to reproduce several essential biomechanical features of the healthy joint during walking, particularly relative to a passive prosthesis, and is shown to adapt to variable cadences. The system is also shown to adapt to slopes over a range of ± 15 deg and to provide support to the user in a manner that is biomimetic, as validated by quasi-static stiffness measurements recorded by the prosthesis. Data from standing trials indicate that the user places more weight on the powered prosthesis than on his passive prosthesis when standing on sloped surfaces, particularly at angles of 10 deg or greater. The authors also demonstrated that the prosthesis typically began providing support within 1 s of initial contact with the ground. Further, the supervisory controller was shown to be effective in switching between walking and standing, as well as in determining ground slope just prior to the transition from the standing controller to the walking controller, where the estimated ground slope was within 1.25 deg of the actual ground slope for all trials. PMID:25955789
A new approach for low-cost noninvasive detection of asymptomatic heart disease at rest.
DeMarzo, Arthur P; Calvin, James E
2007-01-01
It would be useful to have an inexpensive, noninvasive point-of-care test for early detection of asymptomatic heart disease. This study used impedance cardiography (ICG) in a new way to assess heart function that did not use stroke volume or cardiac output. There is a model of the ICG dZ/dt waveform that may be used as a template to represent normal heart function. The hypothesis was that a dZ/dt waveform which deviates from that template should indicate heart dysfunction and therefore heart disease. The objective was to assess the accuracy of this new ICG approach, using echocardiography as the standard. Thirty-four outpatients undergoing echocardiographic testing were tested by ICG while sitting upright and supine. All patients had no symptoms or history of a structural or functional heart disorder. Echocardiographic testing showed 17 patients with abnormalities and 17 as normal. ICG testing yielded 16 true positives for heart dysfunction with 1 false negative (sensitivity = 94%) and 17 true negatives with no false positives (specificity = 100%). Considering that the cost, technical skill, and time required for this ICG test are comparable to those of an electrocardiograph, this new approach has potential as a point-of-care screening test for asymptomatic heart disease.
A Simulator for the Respiratory Tree in Healthy Subjects Derived from Continued Fractions Expansions
NASA Astrophysics Data System (ADS)
Muntean, Ionuţ; Ionescu, Clara; Naşcu, Ioan
2009-04-01
Taking into account the self-similar recurrent geometrical structure of the human respiratory tree, the total respiratory impedance can be represented using an electrical equivalent of a ladder network model. In this paper, the parameters of the respiratory tree are employed in simulation, based on clinical insight and morphology. Once the transfer function of the total input impedance model is calculated, it is further interpreted in its continued fraction expansion form. The purpose is to compare the ladder network structure with the continuous fraction expansion form of the impedance. The results are supporting the theory of fractional-order impedance appearance (also known as constant-phase behaviour) and help understanding the mathematical and morphological basis for constructing a physiology-based simulator of the human lungs.
Monitoring state-of-charge of Ni-MH and Ni-Cd batteries using impedance spectroscopy
NASA Astrophysics Data System (ADS)
Hammouche, Abderrezak; Karden, Eckhard; De Doncker, Rik W.
This paper reports on laboratory studies into the ac impedance spectra of nickel-metal hydride and nickel-cadmium batteries, aiming at finding out possible correlation between electrical parameters, extracted directly from the high frequency region, and the battery state-of-charge (SoC). Impedance diagrams were recorded immediately after interrupting the dc charge, or discharge, current. The study revealed that the series resonance frequency, at which the dynamic cell behavior switches from an inductive character ( Z″>0) to a capacitive one ( Z″<0), varied monotonously as a function of state-of-charge. This behavior was reproducible after intermittent charge and discharge. Half-cell measurements were also conducted to associate the cell impedance with either processes occurring at the positive or negative plates.
Comparison of candidate solar array maximum power utilization approaches. [for spacecraft propulsion
NASA Technical Reports Server (NTRS)
Costogue, E. N.; Lindena, S.
1976-01-01
A study was made of five potential approaches that can be utilized to detect the maximum power point of a solar array while sustaining operations at or near maximum power and without endangering stability or causing array voltage collapse. The approaches studied included: (1) dynamic impedance comparator, (2) reference array measurement, (3) onset of solar array voltage collapse detection, (4) parallel tracker, and (5) direct measurement. The study analyzed the feasibility and adaptability of these approaches to a future solar electric propulsion (SEP) mission, and, specifically, to a comet rendezvous mission. Such missions presented the most challenging requirements to a spacecraft power subsystem in terms of power management over large solar intensity ranges of 1.0 to 3.5 AU. The dynamic impedance approach was found to have the highest figure of merit, and the reference array approach followed closely behind. The results are applicable to terrestrial solar power systems as well as to other than SEP space missions.
Ho, Kimberly K; Abrams-Ogg, Anthony C G; Wood, R Darren; O'Sullivan, M Lynne; Kirby, Gordon M; Blois, Shauna L
2015-05-01
The objectives of this study were to establish feline references intervals for 3 commercial whole blood platelet function test analyzer systems: Multiplate analyzer (MP; Roche Diagnostics International Ltd., Rotkreuz, Switzerland), Platelet Function Analyzer-100 (PF: Siemens Canada, Mississauga, Ontario, Canada), and Plateletworks Combo-25 kit (PW; Helena Laboratories, Beaumont, TX). Venipuncture was performed on 55 healthy sedated cats, and platelet aggregation in response to adenosine diphosphate (ADP), collagen (COL), and arachidonic acid (AA; MP only) was assessed using citrated blood. For the MP analyzer, median (95% confidence intervals [CIs]) area under curve (Units) for ADP, COL, and AA agonists were 87 (11-176), 81 (32-129), and 91 (59-129), respectively. For the PF analyzer, median (95% CIs) closure time, using COL-ADP cartridges, was 69 (46-89) sec. For the PW assay, median (95% CIs) percent aggregations for ADP and COL agonists were 71 (18-92) and 49 (9-96), respectively, using impedance hematology analyzer platelet counts, and 94 (25-98) and 68 (14-119), respectively, using flow cytometry hematology analyzer platelet counts. There were low correlations between the PF analyzer (COL-ADP cartridge) and MP analyzer (COL agonist; ρ = 0.11), and between the PF analyzer (COL-ADP cartridge) and PW assay (COL agonist using impedance platelet counts; ρ = 0.14). The PW assay percent aggregations using impedance and flow cytometric platelet counts were correlated for both ADP (ρ = 0.64) and COL (ρ = 0.64) agonists. Platelet function testing using these tests are feasible in cats, but 95% CIs are wide, so single results may be difficult to interpret. Platelet counting by impedance or flow cytometry may be used for the PW assay but are not interchangeable. © 2015 The Author(s).
Supported Silver Nanoparticle and Near-Interface Solution Dynamics in a Deep Eutectic Solvent
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hammons, Joshua A.; Ustarroz, Jon; Muselle, Thibault
2016-01-28
Type III deep eutectic solvents (DES) have attracted significant interest as both environmentally friendly and functional solvents that are, in some ways, advantageous to traditional aqueous systems. While these solvents continue to produce remarkable thin films and nanoparticle assemblies, their interactions with metallic surfaces are complex and difficult to manipulate. In this study, the near-surface region (2–600 nm) of a carbon surface is investigated immediately following silver nanoparticle nucleation and growth. This is accomplished, in situ, using a novel grazing transmission small-angle X-ray scattering approach with simultaneous voltammetry and electrochemical impedance spectroscopy. With this physical and electrochemical approach, the timemore » evolution of three distinct surface interaction phenomena is observed: aggregation and coalescence of Ag nanoparticles, multilayer perturbations induced by nonaggregated Ag nanoparticles, and a stepwise transport of dissolved Ag species from the carbon surface. The multilayer perturbations contain charge-separated regions of positively charged choline-ethylene and negatively charged Ag and Cl species. Both aggregation-coalescence and the stepwise decrease in Ag precursor near the surface are observed to be very slow (~2 h) processes, as both ion and particle transport are significantly impeded in a DES as compared to aqueous electrolytes. Finally, altogether, this study shows how the unique chemistry of the DES changes near the surface and in the presence of nanoparticles that adsorb the constituent species.« less
Analytical solutions with Generalized Impedance Boundary Conditions (GIBC)
NASA Technical Reports Server (NTRS)
Syed, H. H.; Volakis, John L.
1991-01-01
Rigorous uniform geometrical theory of diffraction (UTD) diffraction coefficients are presented for a coated convex cylinder simulated with generalized impedance boundary conditions. In particular, ray solutions are obtained which remain valid in the transition region and reduce uniformly to those in the deep lit and shadow regions. These involve new transition functions in place of the usual Fock-type integrals, characteristics to the impedance cylinder. A uniform asymptotic solution is also presented for observations in the close vicinity of the cylinder. The diffraction coefficients for the convex cylinder are obtained via a generalization of the corresponding ones for the circular cylinder.
Optimal critic learning for robot control in time-varying environments.
Wang, Chen; Li, Yanan; Ge, Shuzhi Sam; Lee, Tong Heng
2015-10-01
In this paper, optimal critic learning is developed for robot control in a time-varying environment. The unknown environment is described as a linear system with time-varying parameters, and impedance control is employed for the interaction control. Desired impedance parameters are obtained in the sense of an optimal realization of the composite of trajectory tracking and force regulation. Q -function-based critic learning is developed to determine the optimal impedance parameters without the knowledge of the system dynamics. The simulation results are presented and compared with existing methods, and the efficacy of the proposed method is verified.
Ibrahim, Fatimah; Thio, Tzer Hwai Gilbert; Faisal, Tarig; Neuman, Michael
2015-03-23
This paper reviews a number of biomedical engineering approaches to help aid in the detection and treatment of tropical diseases such as dengue, malaria, cholera, schistosomiasis, lymphatic filariasis, ebola, leprosy, leishmaniasis, and American trypanosomiasis (Chagas). Many different forms of non-invasive approaches such as ultrasound, echocardiography and electrocardiography, bioelectrical impedance, optical detection, simplified and rapid serological tests such as lab-on-chip and micro-/nano-fluidic platforms and medical support systems such as artificial intelligence clinical support systems are discussed. The paper also reviewed the novel clinical diagnosis and management systems using artificial intelligence and bioelectrical impedance techniques for dengue clinical applications.
SFG synthesis of general high-order all-pass and all-pole current transfer functions using CFTAs.
Tangsrirat, Worapong
2014-01-01
An approach of using the signal flow graph (SFG) technique to synthesize general high-order all-pass and all-pole current transfer functions with current follower transconductance amplifiers (CFTAs) and grounded capacitors has been presented. For general nth-order systems, the realized all-pass structure contains at most n + 1 CFTAs and n grounded capacitors, while the all-pole lowpass circuit requires only n CFTAs and n grounded capacitors. The resulting circuits obtained from the synthesis procedure are resistor-less structures and especially suitable for integration. They also exhibit low-input and high-output impedances and also convenient electronic controllability through the g m-value of the CFTA. Simulation results using real transistor model parameters ALA400 are also included to confirm the theory.
SFG Synthesis of General High-Order All-Pass and All-Pole Current Transfer Functions Using CFTAs
Tangsrirat, Worapong
2014-01-01
An approach of using the signal flow graph (SFG) technique to synthesize general high-order all-pass and all-pole current transfer functions with current follower transconductance amplifiers (CFTAs) and grounded capacitors has been presented. For general nth-order systems, the realized all-pass structure contains at most n + 1 CFTAs and n grounded capacitors, while the all-pole lowpass circuit requires only n CFTAs and n grounded capacitors. The resulting circuits obtained from the synthesis procedure are resistor-less structures and especially suitable for integration. They also exhibit low-input and high-output impedances and also convenient electronic controllability through the g m-value of the CFTA. Simulation results using real transistor model parameters ALA400 are also included to confirm the theory. PMID:24688375
Personalized Nanoparticles for Cancer Therapy: A Call for Greater Precision.
Sahakyan, Nare; Haddad, Amir; Richardson, Shye; Forcha-Etieundem, Valery; Christopher, Lee; Alharbi, Hanan; Campbell, Robert
2017-01-01
Nanotechnology has brought about the advent of personalized medicine in the era of targeted therapeutic strategies for cancer therapy. The ability to exploit tumor features for therapeutic gain has made it possible to manufacture more effective nanomedicines for cancer treatment. However, known obstacles, including the inability to overcome pathophysiological barriers of tumors, have impeded disease management. In spite of this, recent efforts have been made to develop more functionalized nanosystems that utilize the active-targeting approach. This article reviews the FDA-approved cancer drug delivery systems in the general framework of personalized nanomedicine. We discuss the latest efforts in the development of functionalized nano-systems, and summarize relevant ongoing preclinical and clinical trials. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
NASA Astrophysics Data System (ADS)
Russo, Luigi; Sorrentino, Marco; Polverino, Pierpaolo; Pianese, Cesare
2017-06-01
This work focuses on the development of a fast PEMFC impedance model, built starting from both physical and geometrical variables. Buckingham's π theorem is proposed to define non-dimensional parameters that allow suitably describing the relationships linking the physical variables involved in the process under-study to the fundamental dimensions. This approach is a useful solution for those problems, whose first principles-based models are not known, difficult to build or computationally unfeasible. The key contributions of the proposed similarity theory-based modelling approach are presented and discussed. The major advantage resides in its straightforward online applicability, thanks to very low computational burden, while preserving good level of accuracy. This makes the model suitable for several purposes, such as design, control, diagnostics, state of health monitoring and prognostics. Experimental data, collected in different operating conditions, have been analysed to demonstrate the capability of the model to reproduce PEMFC impedance at different loads and temperatures. This results in a reduction of the experimental effort for the FCS lab characterization. Moreover, it is highlighted the possibility to use the model with scaling-up purposes to reproduce the full stack impedance from single-cell one, thus supporting FC design and development from lab-to commercial system-scale.
Impedance Eduction in Large Ducts Containing Higher-Order Modes and Grazing Flow
NASA Technical Reports Server (NTRS)
Watson, Willie R.; Jones, Michael G.
2017-01-01
Impedance eduction test data are acquired in ducts with small and large cross-sectional areas at the NASA Langley Research Center. An improved data acquisition system in the large duct has resulted in increased control of the acoustic energy in source modes and more accurate resolution of higher-order duct modes compared to previous tests. Two impedance eduction methods that take advantage of the improved data acquisition to educe the liner impedance in grazing flow are presented. One method measures the axial propagation constant of a dominant mode in the liner test section (by implementing the Kumarsean and Tufts algorithm) and educes the impedance from an exact analytical expression. The second method solves numerically the convected Helmholtz equation and minimizes an objective function to obtain the liner impedance. The two methods are tested first on data synthesized from an exact mode solution and then on measured data. Results show that when the methods are applied to data acquired in the larger duct with a dominant higher-order mode, the same impedance spectra are educed as that obtained in the small duct where only the plane wave mode propagates. This result holds for each higher-order mode in the large duct provided that the higher-order mode is sufficiently attenuated by the liner.
He, W.; Anderson, R.N.
1998-08-25
A method is disclosed for inverting 3-D seismic reflection data obtained from seismic surveys to derive impedance models for a subsurface region, and for inversion of multiple 3-D seismic surveys (i.e., 4-D seismic surveys) of the same subsurface volume, separated in time to allow for dynamic fluid migration, such that small scale structure and regions of fluid and dynamic fluid flow within the subsurface volume being studied can be identified. The method allows for the mapping and quantification of available hydrocarbons within a reservoir and is thus useful for hydrocarbon prospecting and reservoir management. An iterative seismic inversion scheme constrained by actual well log data which uses a time/depth dependent seismic source function is employed to derive impedance models from 3-D and 4-D seismic datasets. The impedance values can be region grown to better isolate the low impedance hydrocarbon bearing regions. Impedance data derived from multiple 3-D seismic surveys of the same volume can be compared to identify regions of dynamic evolution and bypassed pay. Effective Oil Saturation or net oil thickness can also be derived from the impedance data and used for quantitative assessment of prospective drilling targets and reservoir management. 20 figs.
He, Wei; Anderson, Roger N.
1998-01-01
A method is disclosed for inverting 3-D seismic reflection data obtained from seismic surveys to derive impedance models for a subsurface region, and for inversion of multiple 3-D seismic surveys (i.e., 4-D seismic surveys) of the same subsurface volume, separated in time to allow for dynamic fluid migration, such that small scale structure and regions of fluid and dynamic fluid flow within the subsurface volume being studied can be identified. The method allows for the mapping and quantification of available hydrocarbons within a reservoir and is thus useful for hydrocarbon prospecting and reservoir management. An iterative seismic inversion scheme constrained by actual well log data which uses a time/depth dependent seismic source function is employed to derive impedance models from 3-D and 4-D seismic datasets. The impedance values can be region grown to better isolate the low impedance hydrocarbon bearing regions. Impedance data derived from multiple 3-D seismic surveys of the same volume can be compared to identify regions of dynamic evolution and bypassed pay. Effective Oil Saturation or net oil thickness can also be derived from the impedance data and used for quantitative assessment of prospective drilling targets and reservoir management.
NASA Technical Reports Server (NTRS)
Aslam, Shahid; Jones, Hollis H.
2011-01-01
Care must always be taken when performing noise measurements on high-Tc superconducting materials to ensure that the results are not from the measurement system itself. One situation likely to occur is with low noise transformers. One of the least understood devices, it provides voltage gain for low impedance inputs (< 100 ), e.g., YBaCuO and GdBaCuO thin films, with comparatively lower noise levels than other devices for instance field effect and bipolar junction transistors. An essential point made in this paper is that because of the complex relationships between the transformer ports, input impedance variance alters the transformer s transfer function in particular, the low frequency cutoff shift. The transfer of external and intrinsic transformer noise to the output along with optimization and precautions are treated; all the while, we will cohesively connect the transfer function shift, the load impedance, and the actual noise at the transformer output.
NASA Astrophysics Data System (ADS)
Kobayashi, Kiyoshi; Suzuki, Tohru S.
2018-03-01
A new algorithm for the automatic estimation of an equivalent circuit and the subsequent parameter optimization is developed by combining the data-mining concept and complex least-squares method. In this algorithm, the program generates an initial equivalent-circuit model based on the sampling data and then attempts to optimize the parameters. The basic hypothesis is that the measured impedance spectrum can be reproduced by the sum of the partial-impedance spectra presented by the resistor, inductor, resistor connected in parallel to a capacitor, and resistor connected in parallel to an inductor. The adequacy of the model is determined by using a simple artificial-intelligence function, which is applied to the output function of the Levenberg-Marquardt module. From the iteration of model modifications, the program finds an adequate equivalent-circuit model without any user input to the equivalent-circuit model.
Microfluidic platform for assessing pancreatic islet functionality through dielectric spectroscopy
Heileman, K.; Daoud, J.; Hasilo, C.; Gasparrini, M.; Paraskevas, S.; Tabrizian, M.
2015-01-01
Human pancreatic islets are seldom assessed for dynamic responses to external stimuli. Thus, the elucidation of human islet functionality would provide insights into the progression of diabetes mellitus, evaluation of preparations for clinical transplantation, as well as for the development of novel therapeutics. The objective of this study was to develop a microfluidic platform for in vitro islet culture, allowing the multi-parametric investigation of islet response to chemical and biochemical stimuli. This was accomplished through the fabrication and implementation of a microfluidic platform that allowed the perifusion of islet culture while integrating real-time monitoring using impedance spectroscopy, through microfabricated, interdigitated electrodes located along the microchamber arrays. Real-time impedance measurements provide important dielectric parameters, such as cell membrane capacitance and cytoplasmic conductivity, representing proliferation, differentiation, viability, and functionality. The perifusion of varying glucose concentrations and monitoring of the resulting impedance of pancreatic islets were performed as proof-of-concept validation of the lab-on-chip platform. This novel technique to elucidate the underlying mechanisms that dictate islet functionality is presented, providing new information regarding islet function that could improve the evaluation of islet preparations for transplantation. In addition, it will lead to a better understanding of fundamental diabetes-related islet dysfunction and the development of therapeutics through evaluation of potential drug effects. PMID:26339324
Wavelet analysis of the impedance cardiogram waveforms
NASA Astrophysics Data System (ADS)
Podtaev, S.; Stepanov, R.; Dumler, A.; Chugainov, S.; Tziberkin, K.
2012-12-01
Impedance cardiography has been used for diagnosing atrial and ventricular dysfunctions, valve disorders, aortic stenosis, and vascular diseases. Almost all the applications of impedance cardiography require determination of some of the characteristic points of the ICG waveform. The ICG waveform has a set of characteristic points known as A, B, E ((dZ/dt)max) X, Y, O and Z. These points are related to distinct physiological events in the cardiac cycle. Objective of this work is an approbation of a new method of processing and interpretation of the impedance cardiogram waveforms using wavelet analysis. A method of computer thoracic tetrapolar polyrheocardiography is used for hemodynamic registrations. Use of original wavelet differentiation algorithm allows combining filtration and calculation of the derivatives of rheocardiogram. The proposed approach can be used in clinical practice for early diagnostics of cardiovascular system remodelling in the course of different pathologies.
Single Mode Theory for Impedance Eduction in Large-Scale Ducts with Grazing Flow
NASA Technical Reports Server (NTRS)
Watson, Willie R.; Gerhold, Carl H.; Jones, Michael G.; June, Jason C.
2014-01-01
An impedance eduction theory for a rigid wall duct containing an acoustic liner with an unknown impedance and uniform grazing flow is presented. The unique features of the theory are: 1) non-planar waves propagate in the hard wall sections of the duct, 2) input data consist solely of complex acoustic pressures acquired on a wall adjacent to the liner, and 3) multiple higher-order modes may exist in the direction perpendicular to the liner and the opposite rigid wall. The approach is to first measure the axial propagation constant of a dominant higher-order mode in the liner sample section. This axial propagation constant is then used in conjunction with a closed-form solution to a reduced form of the convected Helmholtz equation and the wall impedance boundary condition to educe the liner impedance. The theory is validated on a conventional liner whose impedance spectrum is educed in two flow ducts with different cross sections. For the frequencies and Mach numbers of interest, no higher-order modes propagate in the hard wall sections of the smaller duct. A benchmark method is used to educe the impedance spectrum in this duct. A dominant higher-order vertical mode propagates in the larger duct for similar test conditions, and the current theory is applied to educe the impedance spectrum. Results show that when the theory is applied to data acquired in the larger duct with a dominant higher-order vertical mode, the same impedance spectra is educed as that obtained in the small duct where only the plane wave mode is present and the benchmark method is used. This result holds for each higher-order vertical mode that is considered.
Edelson, Dana P.; Eilevstjønn, Joar; Weidman, Elizabeth K.; Retzer, Elizabeth; Vanden Hoek, Terry L.; Abella, Benjamin S.
2009-01-01
Objective Hyperventilation is both common and detrimental during cardiopulmonary resuscitation (CPR). Chest wall impedance algorithms have been developed to detect ventilations during CPR. However, impedance signals are challenged by noise artifact from multiple sources, including chest compressions. Capnography has been proposed as an alternate method to measure ventilations. We sought to assess and compare the adequacy of these two approaches. Methods Continuous chest wall impedance and capnography were recorded during consecutive in-hospital cardiac arrests. Algorithms utilizing each of these data sources were compared to a manually determined “gold standard” reference ventilation rate. In addition, a combination algorithm, which utilized the highest of the impedance or capnography values in any given minute, was similarly evaluated. Results Data were collected from 37 cardiac arrests, yielding 438 min of data with continuous chest compressions and concurrent recording of impedance and capnography. The manually calculated mean ventilation rate was 13.3±4.3/min. In comparison, the defibrillator’s impedance-based algorithm yielded an average rate of 11.3±4.4/min (p=0.0001) while the capnography rate was 11.7±3.7/min (p=0.0009). There was no significant difference in sensitivity and positive predictive value between the two methods. The combination algorithm rate was 12.4±3.5/min (p=0.02), which yielded the highest fraction of minutes with respiratory rates within 2/min of the reference. The impedance signal was uninterpretable 19.5% of the time, compared with 9.7% for capnography. However, the signals were only simultaneously non-interpretable 0.8% of the time. Conclusions Both the impedance and capnography-based algorithms underestimated the ventilation rate. Reliable ventilation rate determination may require a novel combination of multiple algorithms during resuscitation. PMID:20036047
NASA Astrophysics Data System (ADS)
Anoraga, J. S.; Bramantyo, B.; Bardosono, S.; Simanungkalit, S. H.; Basiruddin, J.
2017-08-01
Impedance audiometry is not yet routinely used in pressure tests, especially in Indonesia. Direct exposure to pressure in a hyperbaric chamber is sometimes without any assessment of the middle ear or the Eustachian tube function (ETF) of ventilation. Impedance audiometry examinations are important to assess ETF ventilation. This study determined the middle ear pressure value changes associated with the ETF (ventilation) of prospective divers. This study included 29 prospective divers aged 20-40 years without conductive hearing loss. All subjects underwent a modified diving impedance audiometry examination both before and after the pressure test in a double-lock hyperbaric chamber. Using the Toynbee maneuver, the values obtained for changes of pressure in the middle ear were significant before and after the pressure test in the right and left ears: p < 0.001 and p = 0.018, respectively. The impedance audiometry examination is necessary for the selection of candidate divers undergoing pressure tests within a hyperbaric chamber.
Electrode immersion depth determination and control in electroslag remelting furnace
Melgaard, David K [Albuquerque, NM; Beaman, Joseph J [Austin, TX; Shelmidine, Gregory J [Tijeras, NM
2007-02-20
An apparatus and method for controlling an electroslag remelting furnace comprising adjusting electrode drive speed by an amount proportional to a difference between a metric of electrode immersion and a set point, monitoring impedance or voltage, and calculating the metric of electrode immersion depth based upon a predetermined characterization of electrode immersion depth as a function of impedance or voltage.
Cell Electrical Impedance as a Novel Approach for Studies on Senescence Not Based on Biomarkers
Cha, Jung-Joon; Park, Yangkyu; Yun, Joho; Kim, Hyeon Woo; Park, Chang-Ju; Kang, Giseok; Jung, Minhyun; Pak, Boryeong; Jin, Suk-Won
2016-01-01
Senescence of cardiac myocytes is frequently associated with heart diseases. To analyze senescence in cardiac myocytes, a number of biomarkers have been isolated. However, due to the complex nature of senescence, multiple markers are required for a single assay to accurately depict complex physiological changes associated with senescence. In single cells, changes in both cytoplasm and cell membrane during senescence can affect the changes in electrical impedance. Based on this phenomenon, we developed MEDoS, a novel microelectrochemical impedance spectroscopy for diagnosis of senescence, which allows us to precisely measure quantitative changes in electrical properties of aging cells. Using cardiac myocytes isolated from 3-, 6-, and 18-month-old isogenic zebrafish, we examined the efficacy of MEDoS and showed that MEDoS can identify discernible changes in electrical impedance. Taken together, our data demonstrated that electrical impedance in cells at different ages is distinct with quantitative values; these results were comparable with previously reported ones. Therefore, we propose that MEDoS be used as a new biomarker-independent methodology to obtain quantitative data on the biological senescence status of individual cells. PMID:27812531
Three-dimensional electrical impedance tomography: a topology optimization approach.
Mello, Luís Augusto Motta; de Lima, Cícero Ribeiro; Amato, Marcelo Britto Passos; Lima, Raul Gonzalez; Silva, Emílio Carlos Nelli
2008-02-01
Electrical impedance tomography is a technique to estimate the impedance distribution within a domain, based on measurements on its boundary. In other words, given the mathematical model of the domain, its geometry and boundary conditions, a nonlinear inverse problem of estimating the electric impedance distribution can be solved. Several impedance estimation algorithms have been proposed to solve this problem. In this paper, we present a three-dimensional algorithm, based on the topology optimization method, as an alternative. A sequence of linear programming problems, allowing for constraints, is solved utilizing this method. In each iteration, the finite element method provides the electric potential field within the model of the domain. An electrode model is also proposed (thus, increasing the accuracy of the finite element results). The algorithm is tested using numerically simulated data and also experimental data, and absolute resistivity values are obtained. These results, corresponding to phantoms with two different conductive materials, exhibit relatively well-defined boundaries between them, and show that this is a practical and potentially useful technique to be applied to monitor lung aeration, including the possibility of imaging a pneumothorax.
Lovelady, Douglas C.; Friedman, Jennifer; Patel, Sonali; Rabson, David A.; Lo, Chun-Min
2009-01-01
We performed micromotion experiments using electric cell-substrate impedance sensing (ECIS) on a confluent layer of 3T3 fibroblasts exposed to different low levels of the toxin cytochalasin B. This toxin is know to affect actin polymerization and to disrupt cytoskeletal structure and function in cells, changing the morphology of confluent cell cultures and altering the nature of the cellular micromotion, which is measured by ECIS as changes in impedance. By looking at several measures to characterize the long- and short-term correlations in the noise of the impedance time series, we are able to detect the effects of the toxin at concentrations down to 1 μM; there are intriguing hints that the effects may be discernible at levels as low as 0.1 μM. These measures include the power spectrum, the Hurst and detrended-fluctuation-analysis exponents, and the first zero and first 1/e crossings of the autocorrelation function. While most published work with ECIS uses only average impedance values, we demonstrate that noise analysis provides a more sensitive probe. PMID:19026529
Functionalized Thick Film Impedance Sensors for Use in In Vitro Cell Culture.
Bartsch, Heike; Baca, Martin; Fernekorn, Uta; Müller, Jens; Schober, Andreas; Witte, Hartmut
2018-04-05
Multi-electrode arrays find application in electrophysiological recordings. The quality of the captured signals depends on the interfacial contact between electrogenic cells and the electronic system. Therefore, it requires reliable low-impedance electrodes. Low-temperature cofired ceramic technology offers a suitable platform for rapid prototyping of biological reactors and can provide both stable fluid supply and integrated bio-hardware interfaces for recordings in electrogenic cell cultures. The 3D assembly of thick film gold electrodes in in vitro bio-reactors has been demonstrated for neuronal recordings. However, especially when dimensions become small, their performance varies strongly. This work investigates the influence of different coatings on thick film gold electrodes with regard to their influence on impedance behavior. PSS layer, titanium oxynitride and laminin coatings are deposited on LTCC gold electrodes using different 2D and 3D MEA chip designs. Their impedance characteristics are compared and discussed. Titanium oxynitride layers emerged as suitable functionalization. Small 86-µm-electrodes have a serial resistance R s of 32 kOhm and serial capacitance C s of 4.1 pF at 1 kHz. Thick film gold electrodes with such coatings are thus qualified for signal recording in 3-dimensional in vitro cell cultures.
Gutiérrez-Zúñiga, Gabriela Guadalupe; Hernández-López, José Luis
2016-01-01
A gold millielectrode (GME) functionalized with a mixed (16-MHA + EG3SH) self-assembled monolayer (SAM) was used to fabricate an indirect enzyme-linked immunosorbent assay (ELISA) immunosensor for the sensitive detection of prostate-specific antigen (PSA), a prostate cancer (PCa) biomarker, in human serum samples. To address and minimize the issue of non-specific protein adsorption, an organic matrix (amine-PEG3-biotin/avidin) was assembled on the previously functionalized electrode surface to build up an ordered and hierarchically organized interfacial supramolecular architecture: Au/16-MHA/EG3SH/amine-PEG3-biotin/avidin. The electrode was then exposed to serum samples at different concentrations of a sandwich-type immunocomplex molecule ((Btn)Ab-AgPSA-(HRP)Ab), and its interfacial properties were characterized using electrochemical impedance spectroscopy (EIS). Calibration curves for polarization resistance (RP) and capacitance (1/C) vs. total and free PSA concentrations were obtained and their analytical quality parameters were determined. This approach was compared with results obtained from a commercially available ELISA immunosensor. The results obtained in this work showed that the proposed immunosensor can be successfully applied to analyze serum samples of patients representative of the Mexican population. Copyright © 2015 Elsevier B.V. All rights reserved.
Efficient Scavenging of Solar and Wind Energies in a Smart City.
Wang, Shuhua; Wang, Xue; Wang, Zhong Lin; Yang, Ya
2016-06-28
To realize the sustainable energy supply in a smart city, it is essential to maximize energy scavenging from the city environments for achieving the self-powered functions of some intelligent devices and sensors. Although the solar energy can be well harvested by using existing technologies, the large amounts of wasted wind energy in the city cannot be effectively utilized since conventional wind turbine generators can only be installed in remote areas due to their large volumes and safety issues. Here, we rationally design a hybridized nanogenerator, including a solar cell (SC) and a triboelectric nanogenerator (TENG), that can individually/simultaneously scavenge solar and wind energies, which can be extensively installed on the roofs of the city buildings. Under the same device area of about 120 mm × 22 mm, the SC can deliver a largest output power of about 8 mW, while the output power of the TENG can be up to 26 mW. Impedance matching between the SC and TENG has been achieved by using a transformer to decrease the impedance of the TENG. The hybridized nanogenerator has a larger output current and a better charging performance than that of the individual SC or TENG. This research presents a feasible approach to maximize solar and wind energies scavenging from the city environments with the aim to realize some self-powered functions in smart city.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Yanlin; Wang, Mi; Yao, Jun
2014-04-11
Electrical impedance tomography (EIT) is one of the process tomography techniques to provide an on-line non-invasive imaging for multiphase flow measurement. With EIT measurements, the images of impedance real part, impedance imaginary part, phase angle, and magnitude can be obtained. However, most of the applications of EIT in the process industries rely on the conductivity difference between two phases in fluids to obtain the concentration profiles. It is not common to use the imaginary part or phase angle due to the dominant change in conductivity or complication in the use of other impedance information. In a solid-liquid two phases systemmore » involving nano- or submicro-particles, characterisation of particles (e.g. particle size and concentration) have to rely on the measurement of impedance phase angle or imaginary part. Particles in a solution usually have an electrical double layer associated with their surfaces and can form an induced electrical dipole moment due to the polarization of the electrical double layer under the influence of an alternating electric field. Similar to EIT, electrical impedance spectroscopy (EIS) measurement can record the electrical impedance data, including impedance real part, imaginary part and phase angle (θ), which are caused by the polarization of the electrical double layer. These impedance data are related to the particle characteristics e.g. particle size, particle and ionic concentrations in the aqueous medium, therefore EIS method provides a capability for characterising the particles in suspensions. Electrical impedance tomography based on EIS measurement or namely, electrical impedance tomography spectroscopy (EITS) could image the spatial distribution of particle characteristics. In this paper, a new method, including test set-up and data analysis, for characterisation of particles in suspensions are developed through the experimental approach. The experimental results on tomographic imaging of colloidal particles based on EIS measurement using a sensor of 8 electrodes are reported. Results have demonstrated the potential as well as revealed the challenge in the use of EIS and EITS for characterisation of particle in suspension.« less
NASA Astrophysics Data System (ADS)
Kim, Raeyoung; Nam, Yoonkey
2015-04-01
Objective. Platinum black (PtBK) has long been used for microelectrode fabrication owing to its high recording performance of neural signals. The porous structure of PtBK enlarges the surface area and lowers the impedance, which results in background noise reduction. However, the brittleness of PtBK has been a problem in practice. In this work, we report mechanically stable PtBK microelectrodes using a bioinspired adhesive film, polydopamine (pDA), while maintaining the low impedance of PtBK. Approach. The pDA layer was incorporated into the PtBK structure through electrochemical layer-by-layer deposition. Varying the number of layers and the order of materials, multi-layered pDA-PtBK hybrids were fabricated and the electrical properties, both impedance and charge injection limit, were evaluated. Main results. Multilayered pDA-PtBK hybrids had electrical impedances as low as PtBK controls and charge injection limit twice larger than controls. For the 30 min-ultrasonication agitation test, impedance levels rarely changed for some of the pDA-PtBK hybrids indicating that the pDA improved the mechanical property of the PtBK structures. The pDA-PtBK hybrid microelectrodes readily recorded neural signals of cultured hippocampal neurons, where background noise levels and signal-to-noise were 2.43 ∼ 3.23 μVrms and 28.4 ∼ 69.1, respectively. Significance. The developed pDA-PtBK hybrid microelectrodes are expected to be applicable to neural sensors for neural prosthetic studies.
Impedance microflow cytometry for viability studies of microorganisms
NASA Astrophysics Data System (ADS)
Di Berardino, Marco; Hebeisen, Monika; Hessler, Thomas; Ziswiler, Adrian; Largiadèr, Stephanie; Schade, Grit
2011-02-01
Impedance-based Coulter counters and its derivatives are widely used cell analysis tools in many laboratories and use normally DC or low frequency AC to perform these electrical analyses. The emergence of micro-fabrication technologies in the last decade, however, provides a new means of measuring electrical properties of cells. Microfluidic approaches combined with impedance spectroscopy measurements in the radio frequency (RF) range increase sensitivity and information content and thus push single cell analyses beyond simple cell counting and sizing applications towards multiparametric cell characterization. Promising results have been shown already in the fields of cell differentiation and blood analysis. Here we emphasize the potential of this technology by presenting new data obtained from viability studies on microorganisms. Impedance measurements of several yeast and bacteria strains performed at frequencies around 10 MHz enable an easy discrimination between dead and viable cells. Moreover, cytotoxic effects of antibiotics and other reagents, as well as cell starvation can also be monitored easily. Control analyses performed with conventional flow cytometers using various fluorescent dyes (propidium iodide, oxonol) indicate a good correlation and further highlight the capability of this device. The label-free approach makes on the one hand the use of usually expensive fluorochromes obsolete, on the other hand practically eliminates laborious sample preparation procedures. Until now, online cell monitoring was limited to the determination of viable biomass, which provides rather poor information of a cell culture. Impedance microflow cytometry, besides other aspects, proposes a simple solution to these limitations and might become an important tool for bioprocess monitoring applications in the biotech industry.
Martinucci, I; de Bortoli, N; Savarino, E; Piaggi, P; Bellini, M; Antonelli, A; Savarino, V; Frazzoni, M; Marchi, S
2014-04-01
Recently, it has been suggested that low esophageal basal impedance may reflect impaired mucosal integrity and increased acid sensitivity. We aimed to compare baseline impedance levels in patients with heartburn and pathophysiological characteristics related to functional heartburn (FH) divided into two groups on the basis of symptom relief after proton pump inhibitors (PPIs). Patients with heartburn and negative endoscopy were treated with esomeprazole or pantoprazole 40 mg daily for 8 weeks. According to MII-pH (off therapy) analysis, patients with normal acid exposure time (AET), normal reflux number, and lack of association between symptoms and refluxes were selected; of whom 30 patients with a symptom relief higher than 50% after PPIs composed Group A, and 30 patients, matched for sex and age, without symptom relief composed Group B. A group of 20 healthy volunteers (HVs) was enrolled. For each patient and HV, we evaluated the baseline impedance levels at channel 3, during the overnight rest, at three different times. Group A (vs Group B) showed an increase in the following parameters: mean AET (1.4 ± 0.8% vs 0.5 ± 0.6%), mean reflux number (30.4 ± 8.7 vs 24 ± 6.9), proximal reflux number (11.1 ± 5.2 vs 8.2 ± 3.6), acid reflux number (17.9 ± 6.1 vs 10.7 ± 6.9). Baseline impedance levels were lower in Group A than in Group B and in HVs (p < 0.001). Evaluating baseline impedance levels in patients with heartburn and normal AET could achieve a better understanding of pathophysiology in reflux disease patients, and could improve the distinction between FH and hypersensitive esophagus. © 2014 John Wiley & Sons Ltd.
On the long range propagation of sound over irregular terrain
NASA Technical Reports Server (NTRS)
Howe, M. S.
1984-01-01
The theory of sound propagation over randomly irregular, nominally plane terrain of finite impedance is discussed. The analysis is an extension of the theory of coherent scatter originally proposed by Biot for an irregular rigid surface. It combines Biot's approach, wherein the surface irregularities are modeled by a homogeneous distribution of hemispherical bosses, with more conventional analyses in which the ground is modeled as a smooth plane of finite impedance. At sufficiently low frequencies the interaction of the surface irregularities with the nearfield of a ground-based source leads to the production of surface waves, which are effective in penetrating the ground shadow zone predicted for a smooth surface of the same impedance.
Impedance approach to designing efficient vibration energy absorbers
NASA Astrophysics Data System (ADS)
Bobrovnitskii, Y. I.; Morozov, K. D.; Tomilina, T. M.
2017-03-01
The concept introduced previously by the authors on the best sound absorber having the maximum allowable efficiency in absorbing the energy of an incident sound field has been extended to arbitrary linear elastic media and structures. Analytic relations have been found for the input impedance characteristics that the best vibrational energy absorber should have. The implementation of these relations is the basis of the proposed impedance method of designing efficient vibration and noise absorbers. We present the results of a laboratory experiment that confirms the validity of the obtained theoretical relations, and we construct the simplest best vibration absorber. We also calculate the parameters and demonstrate the efficiency of a dynamic vibration absorber as the best absorber.
Eddy current inspection of weld defects in tubing
NASA Technical Reports Server (NTRS)
Katragadda, G.; Lord, W.
1992-01-01
An approach using differential probes for the inspection of weld defects in tubing is studied. Finite element analysis is used to model the weld regions and defects. Impedance plane signals are predicted for different weld defect types and compared wherever possible with signals from actual welds in tubing. Results show that detection and sizing of defects in tubing is possible using differential eddy current techniques. The phase angle of the impedance plane trajectory gives a good indication of the sizing of the crack. Data on the type of defect can be obtained from the shape of the impedance plane trajectory and the phase. Depending on the skin depth, detection of outer wall, inner wall, and subsurface defects is possible.
Impaired esophageal motor function in eosinophilic esophagitis.
Santander, Cecilio; Chavarría-Herbozo, Carlos M; Becerro-González, Irene; Burgos-Santamaría, Diego
2015-10-01
Eosinophilic esophagitis is a chronic immunoallergic inflammatory disease of the esophagus that represents a major cause of digestive morbidity among the pediatric and young adult populations. Despite the fact that key symptoms in adults include dysphagia and food impaction, many patients lack structural changes in the esophagus to account for their complaints, which suggests the presence of underlying motor disorders and esophageal distensibility impairment. In the last few years the esophageal motility of these patients has been studied using various approaches, most particularly high-resolution manometry, ambulatory manometry, and impedance planimetry. This review focuses on the most relevant findings and scientific evidence regarding esophageal motor disorders in eosinophilic esophagitis.
Electroencephalographic monitoring of complex mental tasks
NASA Technical Reports Server (NTRS)
Guisado, Raul; Montgomery, Richard; Montgomery, Leslie; Hickey, Chris
1992-01-01
Outlined here is the development of neurophysiological procedures to monitor operators during the performance of cognitive tasks. Our approach included the use of electroencepalographic (EEG) and rheoencephalographic (REG) techniques to determine changes in cortical function associated with cognition in the operator's state. A two channel tetrapolar REG, a single channel forearm impedance plethysmograph, a Lead I electrocardiogram (ECG) and a 21 channel EEG were used to measure subject responses to various visual-motor cognitive tasks. Testing, analytical, and display procedures for EEG and REG monitoring were developed that extend the state of the art and provide a valuable tool for the study of cerebral circulatory and neural activity during cognition.
Van Houdenhove, Boudewijn; Luyten, Patrick
2008-01-01
Syndromes characterized by chronic, medically unexplained fatigue, effort- and stress-intolerance, and widespread pain are highly prevalent in medicine. In chronic fatigue syndrome (CFS) and fibromyalgia (FM), various perpetuating factors may impair patients' quality of life and functioning and impede recovery. Although cognitive-behavioral and graded-exercise therapy are evidence-based treatments, the effectiveness and acceptability of therapeutic interventions in CFS/FM may largely depend on a customized approach taking the heterogeneity of perpetuating factors into account. Further research should clarify the aim and outcome of different treatment strategies in CFS/FM, as well as the underlying mechanisms of change, including those facilitating neurobiological recovery.
NASA Technical Reports Server (NTRS)
Hamley, John A.
1990-01-01
Experiments were conducted to define the interface characteristics and constraints of 1 kW class arcjets run on simulated decomposition products of hydrazine and power processors. The impacts of power supply output current ripple on arcjet performance were assessed by variation of the ripple frequency from 100 Hz to 100 kHz with 10 percent peak-to-peak ripple amplitude at 1.2 kW. Ripple had no significant effects on thrust, specific impulse or efficiency. The impact of output ripple on thruster lifetime was not assessed. The static and dynamic impedances of the arcjet were quantified with two thrusters of nearly identical configuration. Superposition of an AC component on the DC arc current was used to characterize the dynamic impedance as a function of flow rate and DC current level. A mathematical model was formulated from these data. Both the static and dynamic impedance magnitude were found to be dependent on mass flow rate. The amplitude of the AC component was found to have little effect on the dynamic impedance. Reducing the DC level from 10 to 8 amps led to a large change in the magnitude of the dynamic impedance with no observable phase change. The impedance data compared favorably between the two thrusters.
NASA Astrophysics Data System (ADS)
Depernet, Daniel; Ba, Oumar; Berthon, Alain
2012-12-01
This paper presents a contribution to implementation of hybrid power plants in rural areas without electricity in Senegal. Wind and photovoltaic generators coupling is used to benefit from renewable energy resources in this country. Lead acid storage batteries are coupled with the generators to ensure smoothness of the electricity generation. This work is focused in particular on the development of a low cost online impedance spectroscopy method to address the problem of limited lifetime of batteries and the difficulties of their maintenance in isolated areas. Control of static converter associated with the battery is adapted to integrate the functionality of characterization of batteries by impedance spectroscopy. An experimental platform developed in the laboratory has validated the method for online measurement of battery impedance spectrum and to initiate a phase of data monitoring.
Niescierowicz, Katarzyna; Caro, Lydia; Cherezov, Vadim; Vivaudou, Michel; Moreau, Christophe J
2014-01-07
Structural studies of G protein-coupled receptors (GPCRs) extensively use the insertion of globular soluble protein domains to facilitate their crystallization. However, when inserted in the third intracellular loop (i3 loop), the soluble protein domain disrupts their coupling to G proteins and impedes the GPCRs functional characterization by standard G protein-based assays. Therefore, activity tests of crystallization-optimized GPCRs are essentially limited to their ligand binding properties using radioligand binding assays. Functional characterization of additional thermostabilizing mutations requires the insertion of similar mutations in the wild-type receptor to allow G protein-activation tests. We demonstrate that ion channel-coupled receptor technology is a complementary approach for a comprehensive functional characterization of crystallization-optimized GPCRs and potentially of any engineered GPCR. Ligand-induced conformational changes of the GPCRs are translated into electrical signal and detected by simple current recordings, even though binding of G proteins is sterically blocked by the added soluble protein domain. Copyright © 2014 Elsevier Ltd. All rights reserved.
Wang, Fei; Clément, Nicolas; Ducatteau, Damien; Troadec, David; Tanbakuchi, Hassan; Legrand, Bernard; Dambrine, Gilles; Théron, Didier
2014-10-10
We present a method to characterize sub-10 nm capacitors and tunnel junctions by interferometric scanning microwave microscopy (iSMM) at 7.8 GHz. At such device scaling, the small water meniscus surrounding the iSMM tip should be reduced by proper tip tuning. Quantitative impedance characterization of attofarad range capacitors is achieved using an 'on-chip' calibration kit facing thousands of nanodevices. Nanoscale capacitors and tunnel barriers were detected through variations in the amplitude and phase of the reflected microwave signal, respectively. This study promises quantitative impedance characterization of a wide range of emerging functional nanoscale devices.
NASA Technical Reports Server (NTRS)
Syed, Hasnain H.; Volakis, John L.
1991-01-01
Rigorous uniform geometrical theory of diffraction (UGTD) diffraction coefficients are presented for a coated convex cylinder simulated with generalized impedance boundary conditions. In particular, ray solutions are obtained which remain valid in the transition region and reduce uniformly to those in the deep lit and shadow regions. These involve new transition functions in place of the usual Fock-type integrals, characteristic to the impedance cylinder. A uniform asymptotic solution is also presented for observations in the close vicinity of the cylinder. As usual, the diffraction coefficients for the convex cylinder are obtained via a generalization of the corresponding ones for the circular cylinder.
Impedance spectroscopy of water soluble resin modified by zirconium sulphate
NASA Astrophysics Data System (ADS)
Joseph, Anandraj; Joshi, Girish M.
2018-04-01
We successfully modified water soluble resin polyvinyl alcohol (PVA) by loading zirconium sulphate (ZrSO4). We demonstrated the measurement of electrical properties by using impedance analyser across frequency range (10 Hz-1 MHz) and the temperature range of (30°C to 150°C). The impedance spectroscopy demonstrates decrease in bulk resistance as a function of temperature loading of zirconia 2.5 wt. %. Increase in AC (10-5 S/cm and DC conductivity (10- 2 S/m) observed due to ionic contribution of zirconia. However, the electrical properties of PVA/ZrSO4 composite useful to develop battery electrolyte applications.
A surface impedance-based three-channel acoustic metasurface retroreflector
NASA Astrophysics Data System (ADS)
Shen, Chen; Díaz-Rubio, Ana; Li, Junfei; Cummer, Steven A.
2018-04-01
We propose the design and measurement of an acoustic metasurface retroreflector that works at three discrete incident angles. An impedance model is developed such that for acoustic waves impinging at -60°, the reflected wave is defined by the surface impedance of the metasurface, which is realized by a periodic grating. At 0° and 60°, the retroreflection condition can be fulfilled by the diffraction of the surface. The thickness of the metasurface is about half of the operating wavelength and the retroreflector functions without parasitic diffraction associated with conventional gradient-index metasurfaces. Such highly efficient and compact retroreflectors open up possibilities in metamaterial-based acoustic sensing and communications.
Ravicz, M E; Rosowski, J J; Voigt, H F
1992-07-01
This is the first paper of a series dealing with sound-power collection by the auditory periphery of the gerbil. The purpose of the series is to quantify the physiological action of the gerbil's relatively large tympanic membrane and middle-ear air cavities. To this end the middle-ear input impedance ZT was measured at frequencies between 10 Hz and 18 kHz before and after manipulations of the middle-ear cavity. The frequency dependence of ZT is consistent with that of the middle-ear transfer function computed from extant data. Comparison of the impedance and transfer function suggests a middle-ear transformer ratio of 50 at frequencies below 1 kHz, substantially smaller than the anatomical value of 90 [Lay, J. Morph. 138, 41-120 (1972)]. Below 1 kHz the data suggest a low-frequency acoustic stiffness KT for the middle ear of 970 Pa/mm3 and a stiffness of the middle-ear cavity of 720 Pa/mm3 (middle-ear volume V MEC of 195 mm3); thus the middle-ear air spaces contribute about 70% of the acoustic stiffness of the auditory periphery. Manipulations of a middle-ear model suggest that decreases in V MEC lead to proportionate increases in KT but that further increases in middle-ear cavity volume produce only limited decreases in middle-ear stiffness. The data and the model point out that the real part of the middle-ear impedance at frequencies below 100 Hz is determined primarily by losses within the middle-ear cavity. The measured impedance is comparable in magnitude and frequency dependence to the impedance in several larger mammalian species commonly used in auditory research. A comparison of low-frequency stiffness and anatomical dimensions among several species suggests that the large middle-ear cavities in gerbil act to reduce the middle-ear stiffness at low frequencies. A description of sound-power collection by the gerbil ear requires a description of the function of the external ear.
Schmid, Thomas; Bogdan, Martin; Günzel, Dorothee
2013-01-01
Quantifying changes in partial resistances of epithelial barriers in vitro is a challenging and time-consuming task in physiology and pathophysiology. Here, we demonstrate that electrical properties of epithelial barriers can be estimated reliably by combining impedance spectroscopy measurements, mathematical modeling and machine learning algorithms. Conventional impedance spectroscopy is often used to estimate epithelial capacitance as well as epithelial and subepithelial resistance. Based on this, the more refined two-path impedance spectroscopy makes it possible to further distinguish transcellular and paracellular resistances. In a next step, transcellular properties may be further divided into their apical and basolateral components. The accuracy of these derived values, however, strongly depends on the accuracy of the initial estimates. To obtain adequate accuracy in estimating subepithelial and epithelial resistance, artificial neural networks were trained to estimate these parameters from model impedance spectra. Spectra that reflect behavior of either HT-29/B6 or IPEC-J2 cells as well as the data scatter intrinsic to the used experimental setup were created computationally. To prove the proposed approach, reliability of the estimations was assessed with both modeled and measured impedance spectra. Transcellular and paracellular resistances obtained by such neural network-enhanced two-path impedance spectroscopy are shown to be sufficiently reliable to derive the underlying apical and basolateral resistances and capacitances. As an exemplary perturbation of pathophysiological importance, the effect of forskolin on the apical resistance of HT-29/B6 cells was quantified.
Ibrahim, Fatimah; Thio, Tzer Hwai Gilbert; Faisal, Tarig; Neuman, Michael
2015-01-01
This paper reviews a number of biomedical engineering approaches to help aid in the detection and treatment of tropical diseases such as dengue, malaria, cholera, schistosomiasis, lymphatic filariasis, ebola, leprosy, leishmaniasis, and American trypanosomiasis (Chagas). Many different forms of non-invasive approaches such as ultrasound, echocardiography and electrocardiography, bioelectrical impedance, optical detection, simplified and rapid serological tests such as lab-on-chip and micro-/nano-fluidic platforms and medical support systems such as artificial intelligence clinical support systems are discussed. The paper also reviewed the novel clinical diagnosis and management systems using artificial intelligence and bioelectrical impedance techniques for dengue clinical applications. PMID:25806872
NASA Astrophysics Data System (ADS)
Liu, Hai-Tao; Wen, Zhi-Yu; Xu, Yi; Shang, Zheng-Guo; Peng, Jin-Lan; Tian, Peng
2017-09-01
In this paper, an integrated microfluidic analysis microsystems with bacterial capture enrichment and in-situ impedance detection was purposed based on microfluidic chips dielectrophoresis technique and electrochemical impedance detection principle. The microsystems include microfluidic chip, main control module, and drive and control module, and signal detection and processing modulet and result display unit. The main control module produce the work sequence of impedance detection system parts and achieve data communication functions, the drive and control circuit generate AC signal which amplitude and frequency adjustable, and it was applied on the foodborne pathogens impedance analysis microsystems to realize the capture enrichment and impedance detection. The signal detection and processing circuit translate the current signal into impendence of bacteria, and transfer to computer, the last detection result is displayed on the computer. The experiment sample was prepared by adding Escherichia coli standard sample into chicken sample solution, and the samples were tested on the dielectrophoresis chip capture enrichment and in-situ impedance detection microsystems with micro-array electrode microfluidic chips. The experiments show that the Escherichia coli detection limit of microsystems is 5 × 104 CFU/mL and the detection time is within 6 min in the optimization of voltage detection 10 V and detection frequency 500 KHz operating conditions. The integrated microfluidic analysis microsystems laid the solid foundation for rapid real-time in-situ detection of bacteria.
Karayama, M; Inui, N; Mori, K; Kono, M; Hozumi, H; Suzuki, Y; Furuhashi, K; Hashimoto, D; Enomoto, N; Fujisawa, T; Nakamura, Y; Watanabe, H; Suda, T
2018-03-01
Respiratory impedance comprises the resistance and reactance of the respiratory system and can provide detailed information on respiratory function. However, details of the relationship between impedance and morphological airway changes in asthma are unknown. We aimed to evaluate the correlation between imaging-based airway changes and respiratory impedance in patients with asthma. Respiratory impedance and spirometric data were evaluated in 72 patients with asthma and 29 reference subjects. We measured the intraluminal area (Ai) and wall thickness (WT) of third- to sixth-generation bronchi using three-dimensional computed tomographic analyses, and values were adjusted by body surface area (BSA, Ai/BSA, and WT/the square root (√) of BSA). Asthma patients had significantly increased respiratory impedance, decreased Ai/BSA, and increased WT/√BSA, as was the case in those without airflow limitation as assessed by spirometry. Ai/BSA was inversely correlated with respiratory resistance at 5 Hz (R5) and 20 Hz (R20). R20 had a stronger correlation with Ai/BSA than did R5. Ai/BSA was positively correlated with forced expiratory volume in 1 second/forced vital capacity ratio, percentage predicted forced expiratory volume in 1 second, and percentage predicted mid-expiratory flow. WT/√BSA had no significant correlation with spirometry or respiratory impedance. Respiratory resistance is associated with airway narrowing. © 2018 John Wiley & Sons Ltd.
Modal description—A better way of characterizing human vibration behavior
NASA Astrophysics Data System (ADS)
Rützel, Sebastian; Hinz, Barbara; Wölfel, Horst Peter
2006-12-01
Biodynamic responses to whole body vibrations are usually characterized in terms of transfer functions, such as impedance or apparent mass. Data measurements from subjects are averaged and analyzed with respect to certain attributes (anthropometrics, posture, excitation intensity, etc.). Averaging involves the risk of identifying unnatural vibration characteristics. The use of a modal description as an alternative method is presented and its contribution to biodynamic modelling is discussed. Modal description is not limited to just one biodynamic function: The method holds for all transfer functions. This is shown in terms of the apparent mass and the seat-to-head transfer function. The advantages of modal description are illustrated using apparent mass data of six male individuals of the same mass percentile. From experimental data, modal parameters such as natural frequencies, damping ratios and modal masses are identified which can easily be used to set up a mathematical model. Following the phenomenological approach, this model will provide the global vibration behavior relating to the input data. The modal description could be used for the development of hardware vibration dummies. With respect to software models such as finite element models, the validation process for these models can be supported by the modal approach. Modal parameters of computational models and of the experimental data can establish a basis for comparison.
Novel method to form adaptive internal impedance profiles in walkers.
Escudero Morland, Maximilano F; Althoefer, Kaspar; Nanayakkara, Thrishantha
2015-01-01
This paper proposes a novel approach to improve walking in prosthetics, orthotics and robotics without closed loop controllers. The approach requires impedance profiles to be formed in a walker and uses state feedback to update the profiles in real-time via a simple policy. This approach is open loop and inherently copes with the challenge of uncertain environment. In application it could be used either online for a walker to adjust its impedance profiles in real-time to compensate for environmental changes, or offline to learn suitable profiles for specific environments. So far we have conducted simulations and experiments to investigate the transient and steady state gaits obtained using two simple update policies to form damping profiles in a passive dynamic walker known as the rimless wheel (RW). The damping profiles are formed in the motor that moves the RW vertically along a rail, analogous to a knee joint, and the two update equations were designed to a) control the angular velocity profile and b) minimise peak collision forces. Simulation results show that the velocity update equation works within limits and can cope with varying ground conditions. Experiment results show the angular velocity average reaching the target as well as the peak force update equation reducing peak collision forces in real-time.
On the Use of Experimental Methods to Improve Confidence in Educed Impedance
NASA Technical Reports Server (NTRS)
Jones, Michael G.; Watson, Willie R.
2011-01-01
Results from impedance eduction methods developed by NASA Langley Research Center are used throughout the acoustic liner community. In spite of recent enhancements, occasional anomalies persist with these methods, generally at frequencies where the liner produces minimal attenuation. This investigation demonstrates an experimental approach to educe impedance with increased confidence over a desired frequency range, by combining results from successive tests with different cavity depths. A series of tests is conducted with three wire-mesh facesheets, for which the results should be weakly dependent on source sound pressure level and mean grazing flow speed. First, a raylometer is used to measure the DC flow resistance of each facesheet. These facesheets are then mounted onto a frame and a normal incidence tube is used to determine their respective acoustic impedance spectra. A comparison of the acoustic resistance component with the DC flow resistance for each facesheet is used to validate the measurement process. Next, each facesheet is successively mounted onto three frames with different cavity depths, and a grazing flow impedance tube is used to educe their respective acoustic impedance spectra with and without mean flow. The no-flow results are compared with those measured in the normal incidence tube to validate the impedance eduction method. Since the anti-resonance frequency varies with cavity depth, each sample provides robust results over a different frequency range. Hence, a combination of results can be used to determine the facesheet acoustic resistance. When combined with the acoustic reactance, observed to be weakly dependent on the source sound pressure level and grazing flow Mach number, the acoustic impedance can be educed with increased confidence. Representative results of these tests are discussed, and the complete database is available in electronic format upon request.
Impedance Control of the Rehabilitation Robot Based on Sliding Mode Control
NASA Astrophysics Data System (ADS)
Zhou, Jiawang; Zhou, Zude; Ai, Qingsong
As an auxiliary treatment, the 6-DOF parallel robot plays an important role in lower limb rehabilitation. In order to improve the efficiency and flexibility of the lower limb rehabilitation training, this paper studies the impedance controller based on the position control. A nonsingular terminal sliding mode control is developed to ensure the trajectory tracking precision and in contrast to traditional PID control strategy in the inner position loop, the system will be more stable. The stability of the system is proved by Lyapunov function to guarantee the convergence of the control errors. Simulation results validate the effectiveness of the target impedance model and show that the parallel robot can adjust gait trajectory online according to the human-machine interaction force to meet the gait request of patients, and changing the impedance parameters can meet the demands of different stages of rehabilitation training.
Method and apparatus for deflection measurements using eddy current effects
NASA Astrophysics Data System (ADS)
Chern, Engmin J.
1993-05-01
A method and apparatus for inserting and moving a sensing assembly with a mechanical positioning assembly to a desired remote location of a surface of a specimen under test and measuring angle and/or deflection by sensing the change in the impedance of at least one sensor coil located in a base plate which has a rotatable conductive plate pivotally mounted thereon so as to uncover the sensor coil(s) whose impedance changes as a function of deflection away from the center line of the base plate in response to the movement of the rotator plate when contacting the surface of the specimen under test is presented. The apparatus includes the combination of a system controller, a sensing assembly, an eddy current impedance measuring apparatus, and a mechanical positioning assembly driven by the impedance measuring apparatus to position the sensing assembly at a desired location of the specimen.
Method and apparatus for deflection measurements using eddy current effects
NASA Technical Reports Server (NTRS)
Chern, Engmin J. (Inventor)
1993-01-01
A method and apparatus for inserting and moving a sensing assembly with a mechanical positioning assembly to a desired remote location of a surface of a specimen under test and measuring angle and/or deflection by sensing the change in the impedance of at least one sensor coil located in a base plate which has a rotatable conductive plate pivotally mounted thereon so as to uncover the sensor coil(s) whose impedance changes as a function of deflection away from the center line of the base plate in response to the movement of the rotator plate when contacting the surface of the specimen under test is presented. The apparatus includes the combination of a system controller, a sensing assembly, an eddy current impedance measuring apparatus, and a mechanical positioning assembly driven by the impedance measuring apparatus to position the sensing assembly at a desired location of the specimen.
Asymmetric material impact: Achieving free surfaces velocities nearly double that of the projectile
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aslam, Tariq; Dattelbaum, Dana; Gustavsen, Richard
Hypervelocity impact speeds are often limited by practical considerations in guns and explosive driven systems. In particular, for gas guns (both powder driven and light gas guns), there is the general trend that higher projectile speeds often come at the expense of smaller diameters, and thus less time for examining shock phenomena prior to two dimensional release waves affecting the observed quantities of interest. Similarly, explosive driven systems have their own set of limiting conditions due to limitations in explosive energy and size of devices required as engineering dimensions increase. The focus in this study is to present a methodologymore » of obtaining free surface velocities well in excess of the projectile velocity. The key to this approach is in using a high impedance projectile that impacts a series of progressively lower impedance materials. The free surface velocity (if they were separated) of each of the progressively lower impedance materials would increase for each material. The theory behind this approach, as well as experimental results are presented.« less
Asymmetric material impact: Achieving free surfaces velocities nearly double that of the projectile
Aslam, Tariq; Dattelbaum, Dana; Gustavsen, Richard; ...
2015-05-19
Hypervelocity impact speeds are often limited by practical considerations in guns and explosive driven systems. In particular, for gas guns (both powder driven and light gas guns), there is the general trend that higher projectile speeds often come at the expense of smaller diameters, and thus less time for examining shock phenomena prior to two dimensional release waves affecting the observed quantities of interest. Similarly, explosive driven systems have their own set of limiting conditions due to limitations in explosive energy and size of devices required as engineering dimensions increase. The focus in this study is to present a methodologymore » of obtaining free surface velocities well in excess of the projectile velocity. The key to this approach is in using a high impedance projectile that impacts a series of progressively lower impedance materials. The free surface velocity (if they were separated) of each of the progressively lower impedance materials would increase for each material. The theory behind this approach, as well as experimental results are presented.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Bo; Shi, Xiaojie M.; Li, Yalong
Hybrid ac/dc transmission extends the power transfer capacity of existing long ac lines closer to their thermal limit, by superposing the dc current onto three-phase ac lines through a zigzag transformer. However, this transformer could suffer saturation under unbalanced line impedance conditions. This paper introduces the concept of hybrid line impedance conditioner (HLIC) as a cost-effective approach to compensate for the line unbalance and therefore avoid saturation. The topology and operation principle are presented. The two-level control strategy is described, which enables autonomous adaptive regulation without the need of system-level control. Design and implementation are also analyzed, including dc-link capacitancemore » as one of the key line conditioner components, HLIC installation, and protection under fault conditions. The cost study on this HLIC-based hybrid system is also performed to reveal the benefits of the solution. In conclusion, simulation results and experimental results based on a down-scaled prototype are provided to verify the feasibility of the proposed approach.« less
Liu, Bo; Shi, Xiaojie M.; Li, Yalong; ...
2016-09-13
Hybrid ac/dc transmission extends the power transfer capacity of existing long ac lines closer to their thermal limit, by superposing the dc current onto three-phase ac lines through a zigzag transformer. However, this transformer could suffer saturation under unbalanced line impedance conditions. This paper introduces the concept of hybrid line impedance conditioner (HLIC) as a cost-effective approach to compensate for the line unbalance and therefore avoid saturation. The topology and operation principle are presented. The two-level control strategy is described, which enables autonomous adaptive regulation without the need of system-level control. Design and implementation are also analyzed, including dc-link capacitancemore » as one of the key line conditioner components, HLIC installation, and protection under fault conditions. The cost study on this HLIC-based hybrid system is also performed to reveal the benefits of the solution. In conclusion, simulation results and experimental results based on a down-scaled prototype are provided to verify the feasibility of the proposed approach.« less
ONERA-NASA Cooperative Effort on Liner Impedance Eduction
NASA Technical Reports Server (NTRS)
Primus, Julien; Piot, Estelle; Simon, Frank; Jones, Michael G.; Watson, Willie R
2013-01-01
As part of a cooperation between ONERA and NASA, the liner impedance eduction methods developed by the two research centers are compared. The NASA technique relies on an objective function built on acoustic pressure measurements located on the wall opposite the test liner, and the propagation code solves the convected Helmholtz equation in uniform ow using a finite element method that implements a continuous Galerkin discretization. The ONERA method uses an objective function based either on wall acoustic pressure or on acoustic velocity acquired above the liner by Laser Doppler Anemometry, and the propagation code solves the linearized Euler equations by a discontinuous Galerkin discretization. Two acoustic liners are tested in both ONERA and NASA ow ducts and the measured data are treated with the corresponding impedance eduction method. The first liner is a wire mesh facesheet mounted onto a honeycomb core, designed to be linear with respect to incident sound pressure level and to grazing ow velocity. The second one is a conventional, nonlinear, perforate-over-honeycomb single layer liner. Configurations without and with ow are considered. For the nonlinear liner, the comparison of liner impedance educed by NASA and ONERA shows a sensitivity to the experimental conditions, namely to the nature of the source and to the sample width.
Diggikar, Rahul S; Patil, Rajendra H; Kale, Sheetal B; Thombre, Dipalee K; Gade, Wasudeo N; Kulkarni, Milind V; Kale, Bharat B
2013-09-01
Reoccurrence of infectious diseases and ability of pathogens to resist antibacterial action has raised enormous challenges which may possibly be confronted by nanotechnology routes. In the present study, uniformly embedded silver nanoparticles in orthorhombic nanotubes of lithium vanadium oxide (LiV2O5/Ag) were explored as an impeder of bacterial growth and biofilm. The LiV2O5/Ag nanocomposites have impeded growth of Gram-positive Bacillus subtilis NCIM 2063 and Gram-negative Escherichia coli NCIM 2931 at 60 to 120 μg/mL. It also impeded the biofilm in Pseudomonas aeruginosa NCIM 2948 at 12.5 to 25 μg/mL. Impedance in the growth and biofilm occurs primarily by direct action of the nanocomposites on the cell surfaces of test organisms as revealed by surface perturbation in scanning electron microscopy. As the metabolic growth and biofilm formation phenomena of pathogens play a central role in progression of pathogenesis, LiV2O5/Ag nanocomposite-based approach is likely to curb the menace of reoccurrence of infectious diseases. Thus, LiV2O5/Ag nanocomposites can be viewed as a promising candidate in biofabrication of biomedical materials.
Acoustical transmission-line model of the middle-ear cavities and mastoid air cells.
Keefe, Douglas H
2015-04-01
An acoustical transmission line model of the middle-ear cavities and mastoid air cell system (MACS) was constructed for the adult human middle ear with normal function. The air-filled cavities comprised the tympanic cavity, aditus, antrum, and MACS. A binary symmetrical airway branching model of the MACS was constructed using an optimization procedure to match the average total volume and surface area of human temporal bones. The acoustical input impedance of the MACS was calculated using a recursive procedure, and used to predict the input impedance of the middle-ear cavities at the location of the tympanic membrane. The model also calculated the ratio of the acoustical pressure in the antrum to the pressure in the middle-ear cavities at the location of the tympanic membrane. The predicted responses were sensitive to the magnitude of the viscothermal losses within the MACS. These predicted input impedance and pressure ratio functions explained the presence of multiple resonances reported in published data, which were not explained by existing MACS models.
Diagnosis of Swallowing Disorders: How We Interpret Pharyngeal Manometry.
Cock, Charles; Omari, Taher
2017-03-01
We provide an overview of the clinical application of novel pharyngeal high-resolution impedance manometry (HRIM) with pressure flow analysis (PFA) in our hands with example cases. In our Centre, we base our interpretation of HRIM recordings upon a qualitative assessment of pressure-impedance waveforms during individual swallows, as well as a quantitative assessment of averaged PFA swallow function variables. We provide a description of two global swallowing efficacy measures, the swallow risk index (SRI), reflecting global swallowing dysfunction (higher SRI = greater aspiration risk) and the post-swallow impedance ratio (PSIR) detecting significant post-swallow bolus residue. We describe a further eight swallow function variables specific to the hypopharynx and upper esophageal sphincter (UES), assessing hypo-pharyngeal distension pressure, contractility, bolus presence and flow timing, and UES basal tone, relaxation, opening and contractility. Pharyngeal HRIM has now come of age, being applicable for routine clinical practice to assess the biomechanics of oropharyngeal swallowing dysfunction. In the future, it may guide treatment strategies and allow more objective longitudinal follow-up on clinical outcomes.
Flexible Molybdenum Electrodes towards Designing Affinity Based Protein Biosensors.
Kamakoti, Vikramshankar; Panneer Selvam, Anjan; Radha Shanmugam, Nandhinee; Muthukumar, Sriram; Prasad, Shalini
2016-07-18
Molybdenum electrode based flexible biosensor on porous polyamide substrates has been fabricated and tested for its functionality as a protein affinity based biosensor. The biosensor performance was evaluated using a key cardiac biomarker; cardiac Troponin-I (cTnI). Molybdenum is a transition metal and demonstrates electrochemical behavior upon interaction with an electrolyte. We have leveraged this property of molybdenum for designing an affinity based biosensor using electrochemical impedance spectroscopy. We have evaluated the feasibility of detection of cTnI in phosphate-buffered saline (PBS) and human serum (HS) by measuring impedance changes over a frequency window from 100 mHz to 1 MHz. Increasing changes to the measured impedance was correlated to the increased dose of cTnI molecules binding to the cTnI antibody functionalized molybdenum surface. We achieved cTnI detection limit of 10 pg/mL in PBS and 1 ng/mL in HS medium. The use of flexible substrates for designing the biosensor demonstrates promise for integration with a large-scale batch manufacturing process.
Characteristic impedance of a microchannel with two immiscible microfluids
NASA Astrophysics Data System (ADS)
Jaramillo Raquejo, Daniela
2014-05-01
Consider the case of a microcapillary of radius R with two microfluidic immiscible. The micro-capillary region 0 < r < R1 is occupied by the microfluidic less dense and less viscous; while the microcapillary region R1 <0 < R is occupied by the microfluidic more dense and more viscous. Determine the characteristic impedance of the microcapillary in this case when both microfluidics are driven by the same pressure gradient as the boundary condition at the wall of the microcapillary is of the non-Newtonian slip. The Navier Stokes equation is solved for both microfluidic methods using the Laplace transform. The velocity profiles are expressed in terms of Bessel functions. Similarly, the characteristic impedance of the microcapillary is expressed by a complex formula Bessel functions. Obtain the analytical results are important for designing engineering microdevices with applications in pharmaceutical, food engineering, nanotechnology and biotechnology in general in particular. For future research it is interesting to consider the case of boundary conditions with memory effects.
Assessing heat treatment of chicken breast cuts by impedance spectroscopy.
Schmidt, Franciny C; Fuentes, Ana; Masot, Rafael; Alcañiz, Miguel; Laurindo, João B; Barat, José M
2017-03-01
The aim of this work was to develop a new system based on impedance spectroscopy to assess the heat treatment of previously cooked chicken meat by two experiments; in the first, samples were cooked at different temperatures (from 60 to 90 ℃) until core temperature of the meat reached the water bath temperature. In the second approach, temperature was 80 ℃ and the samples were cooked for different times (from 5 to 55 min). Impedance was measured once samples had cooled. The examined processing parameters were the maximum temperature reached in thermal centre of the samples, weight loss, moisture and the integral of the temperature profile during the cooking-cooling process. The correlation between the processing parameters and impedance was studied by partial least square regressions. The models were able to predict the studied parameters. Our results are essential for developing a new system to control the technological, sensory and safety aspects of cooked meat products on the whole meat processing line.
Modeling power flow in the induction cavity with a two dimensional circuit simulation
NASA Astrophysics Data System (ADS)
Guo, Fan; Zou, Wenkang; Gong, Boyi; Jiang, Jihao; Chen, Lin; Wang, Meng; Xie, Weiping
2017-02-01
We have proposed a two dimensional (2D) circuit model of induction cavity. The oil elbow and azimuthal transmission line are modeled with one dimensional transmission line elements, while 2D transmission line elements are employed to represent the regions inward the azimuthal transmission line. The voltage waveforms obtained by 2D circuit simulation and transient electromagnetic simulation are compared, which shows satisfactory agreement. The influence of impedance mismatch on the power flow condition in the induction cavity is investigated with this 2D circuit model. The simulation results indicate that the peak value of load voltage approaches the maximum if the azimuthal transmission line roughly matches the pulse forming section. The amplitude of output transmission line voltage is strongly influenced by its impedance, but the peak value of load voltage is insensitive to the actual output transmission line impedance. When the load impedance raises, the voltage across the dummy load increases, and the pulse duration at the oil elbow inlet and insulator stack regions also slightly increase.
Using FOCUS to determine the radiation impedance for square transducers
NASA Astrophysics Data System (ADS)
Jennings, Matthew R.; McGough, Robert J.
2012-10-01
The power radiated by an ultrasound transducer is calculated with the radiation resistance, which is the real part of the radiation impedance. For circular transducers, an analytical solution for the radiation impedance is known, but an analytical expression for the radiation impedance is not available for rectangular or square transducers. To determine the radiation resistance in FOCUS, the pressure on the surface of a square transducer is computed with the fast nearfield method, and then the force on the transducer face is computed by integrating the pressure. Results using this approach are numerically evaluated for a range of ka values from 0.1 to 16. The pressure on the transducer face is also computed with the Rayleigh-Sommerfeld integral, and the results are compared. The numerical value of the radiation resistance computed with FOCUS and with the Rayleigh-Sommerfeld integral converge to the same value, although FOCUS calculates the same result in about one-quarter of the time.
Giant magneto-impedance and magneto-inductive effects in amorphous alloys
NASA Astrophysics Data System (ADS)
Panina, L. V.; Mohri, K.; Bushida, K.; Noda, M.
1994-11-01
Recent experiments have discovered giant and sensitive magneto-impedance and magneto-inductive effects in FeCoSiB amorphous wires. These effects include a sensitive change in an ac wire voltage with the application of a small dc longitudinal magnetic field. At low frequencies (1-10 kHz) the inductive voltage drops by 50% for a field of 2 Oe (25%/Oe) reflecting a strong field dependence of the circumferential permeability. At higher frequencies (0.1-10 MHz) when the skin effect is essential, the amplitude of the total wire voltage decreases by 40%-60% for fields of 3-10 Oe (about 10%/Oe). These effects exhibit no hysteresis for the variation of an applied field and can be obtained even in wires of 1 mm length and a few micrometer diameter. These characteristics are very useful to constitute a highly sensitive microsensor head to detect local fields of the order of 10(exp -5) Oe. In this paper, we review recently obtained experimental results on magneto-inductive and magneto-impedance effects and present a detailed discussion for their mechanism, developing a general approach in terms of ac complex impedance in a magnetic conductor. In the case of a strong skin effect the total wire impedance depends on the circumferential permeability through the penetration depth, resulting in the giant magneto-impedance effect.
Modeling of electrical impedance tomography to detect breast cancer by finite volume methods
NASA Astrophysics Data System (ADS)
Ain, K.; Wibowo, R. A.; Soelistiono, S.
2017-05-01
The properties of the electrical impedance of tissue are an interesting study, because changes of the electrical impedance of organs are related to physiological and pathological. Both physiological and pathological properties are strongly associated with disease information. Several experiments shown that the breast cancer has a lower impedance than the normal breast tissue. Thus, the imaging based on impedance can be used as an alternative equipment to detect the breast cancer. This research carries out by modelling of Electrical Impedance Tomography to detect the breast cancer by finite volume methods. The research includes development of a mathematical model of the electric potential field by 2D Finite Volume Method, solving the forward problem and inverse problem by linear reconstruction method. The scanning is done by 16 channel electrode with neighbors method to collect data. The scanning is performed at a frequency of 10 kHz and 100 kHz with three objects numeric includes an anomaly at the surface, an anomaly at the depth and an anomaly at the surface and at depth. The simulation has been successfully to reconstruct image of functional anomalies of the breast cancer at the surface position, the depth position or a combination of surface and the depth.
Broadband spectroscopy of dynamic impedances with short chirp pulses.
Min, M; Land, R; Paavle, T; Parve, T; Annus, P; Trebbels, D
2011-07-01
An impedance spectrum of dynamic systems is time dependent. Fast impedance changes take place, for example, in high throughput microfluidic devices and in operating cardiovascular systems. Measurements must be as short as possible to avoid significant impedance changes during the spectrum analysis, and as long as possible for enlarging the excitation energy and obtaining a better signal-to-noise ratio (SNR). The authors propose to use specific short chirp pulses for excitation. Thanks to the specific properties of the chirp function, it is possible to meet the needs for a spectrum bandwidth, measurement time and SNR so that the most accurate impedance spectrogram can be obtained. The chirp wave excitation can include thousands of cycles when the impedance changes slowly, but in the case of very high speed changes it can be shorter than a single cycle, preserving the same excitation bandwidth. For example, a 100 kHz bandwidth can be covered by the chirp pulse with durations from 10 µs to 1 s; only its excitation energy differs also 10(5) times. After discussing theoretical short chirp properties in detail, the authors show how to generate short chirps in the microsecond range with a bandwidth up to a few MHz by using digital synthesis architectures developed inside a low-cost standard field programmable gate array.
Frequency dispersions of human skin dielectrics.
Poon, C S; Choy, T T
1981-01-01
The electrical properties of many biological materials are known to exhibit frequency dispersions. In the human skin, the impedance measured at various frequencies closely describes a circular locus of the Cole-Cole type in the complex impedance plane. In this report, the formative mechanisms responsible for the anomalous circular-arc behavior of skin impedance were investigated, using data from impedance measurements taken after successive strippings of the skin. The data were analyzed with respect to changes in the parameters of the equivalent Cole-Cole model after each stripping. For an exponential resistivity profile (Tregear, 1966, Physical Functions of Skin; Yamamoto and Yamamoto, 1976, Med. Biol. Eng., 14:151--158), the profile of the dielectric constant was shown to be uniform across the epidermis. Based on these results, a structural model has been formulated in terms of the relaxation theory of Maxwell and Wagner for inhomogeneous dielectric materials. The impedance locus obtained from the model approximates a circular are with phase constant alpha = 0.82, which compares favorably with experimental data. At higher frequencies a constant-phase, frequency-dependent component having the same phase constant alpha is also demonstrated. It is suggested that an approximately rectangular distribution of the relaxation time over the epidermal dielectric sheath is adequate to account for the anomalous frequency characteristics of human skin impedance. PMID:7213928
Corrections Regarding the Impedance of Distance Functions for Several g(d) Functions
ERIC Educational Resources Information Center
Beaman, Jay
1976-01-01
Five functions were introduced for modeling travel behavior in the Beaman article "Distance and the 'Reaction' to Distance as a Function of Distance" published in Vol. 6, No. 3 of "Journal of Leisure Research" with the graphs of the functions printed incorrectly. This is a corrected version. (MM)
In Situ STEM-EELS observation of nanoscale interfacial phenomena in all-solid-state batteries
Wang, Ziying; Santhanagopalan, Dhamodaran; Zhang, Wei; ...
2016-05-03
Behaviors of functional interfaces are crucial factors in the performance and safety of energy storage and conversion devices. Indeed, solid electrode–solid electrolyte interfacial impedance is now considered the main limiting factor in all-solid-state batteries rather than low ionic conductivity of the solid electrolyte. In this paper, we present a new approach to conducting in situ scanning transmission electron microscopy (STEM) coupled with electron energy loss spectroscopy (EELS) in order to uncover the unique interfacial phenomena related to lithium ion transport and its corresponding charge transfer. Our approach allowed quantitative spectroscopic characterization of a galvanostatically biased electrochemical system under in situmore » conditions. Using a LiCoO 2/LiPON/Si thin film battery, an unexpected structurally disordered interfacial layer between LiCoO 2 cathode and LiPON electrolyte was discovered to be inherent to this interface without cycling. During in situ charging, spectroscopic characterization revealed that this interfacial layer evolved to form highly oxidized Co ions species along with lithium oxide and lithium peroxide species. These findings suggest that the mechanism of interfacial impedance at the LiCoO 2/LiPON interface is caused by chemical changes rather than space charge effects. Finally, insights gained from this technique will shed light on important challenges of interfaces in all-solid-state energy storage and conversion systems and facilitate improved engineering of devices operated far from equilibrium.« less
NASA Astrophysics Data System (ADS)
Nicgorski, Dana; Avitabile, Peter
2010-07-01
Frequency-based substructuring is a very popular approach for the generation of system models from component measured data. Analytically the approach has been shown to produce accurate results. However, implementation with actual test data can cause difficulties and cause problems with the system response prediction. In order to produce good results, extreme care is needed in the measurement of the drive point and transfer impedances of the structure as well as observe all the conditions for a linear time invariant system. Several studies have been conducted to show the sensitivity of the technique to small variations that often occur during typical testing of structures. These variations have been observed in actual tested configurations and have been substantiated with analytical models to replicate the problems typically encountered. The use of analytically simulated issues helps to clearly see the effects of typical measurement difficulties often observed in test data. This paper presents some of these common problems observed and provides guidance and recommendations for data to be used for this modeling approach.
Varikuti, Deepthi P; Hoffstaedter, Felix; Genon, Sarah; Schwender, Holger; Reid, Andrew T; Eickhoff, Simon B
2017-04-01
Resting-state functional connectivity analysis has become a widely used method for the investigation of human brain connectivity and pathology. The measurement of neuronal activity by functional MRI, however, is impeded by various nuisance signals that reduce the stability of functional connectivity. Several methods exist to address this predicament, but little consensus has yet been reached on the most appropriate approach. Given the crucial importance of reliability for the development of clinical applications, we here investigated the effect of various confound removal approaches on the test-retest reliability of functional-connectivity estimates in two previously defined functional brain networks. Our results showed that gray matter masking improved the reliability of connectivity estimates, whereas denoising based on principal components analysis reduced it. We additionally observed that refraining from using any correction for global signals provided the best test-retest reliability, but failed to reproduce anti-correlations between what have been previously described as antagonistic networks. This suggests that improved reliability can come at the expense of potentially poorer biological validity. Consistent with this, we observed that reliability was proportional to the retained variance, which presumably included structured noise, such as reliable nuisance signals (for instance, noise induced by cardiac processes). We conclude that compromises are necessary between maximizing test-retest reliability and removing variance that may be attributable to non-neuronal sources.
Varikuti, Deepthi P.; Hoffstaedter, Felix; Genon, Sarah; Schwender, Holger; Reid, Andrew T.; Eickhoff, Simon B.
2016-01-01
Resting-state functional connectivity analysis has become a widely used method for the investigation of human brain connectivity and pathology. The measurement of neuronal activity by functional MRI, however, is impeded by various nuisance signals that reduce the stability of functional connectivity. Several methods exist to address this predicament, but little consensus has yet been reached on the most appropriate approach. Given the crucial importance of reliability for the development of clinical applications, we here investigated the effect of various confound removal approaches on the test-retest reliability of functional-connectivity estimates in two previously defined functional brain networks. Our results showed that grey matter masking improved the reliability of connectivity estimates, whereas de-noising based on principal components analysis reduced it. We additionally observed that refraining from using any correction for global signals provided the best test-retest reliability, but failed to reproduce anti-correlations between what have been previously described as antagonistic networks. This suggests that improved reliability can come at the expense of potentially poorer biological validity. Consistent with this, we observed that reliability was proportional to the retained variance, which presumably included structured noise, such as reliable nuisance signals (for instance, noise induced by cardiac processes). We conclude that compromises are necessary between maximizing test-retest reliability and removing variance that may be attributable to non-neuronal sources. PMID:27550015
NASA Technical Reports Server (NTRS)
Dahl, Milo D.; Sutliff, Daniel L.
2007-01-01
A technique is presented for the analysis of measured data obtained from a rotating microphone rake system. The system is designed to measure the interaction modes of ducted fans. A Fourier analysis of the data from the rotating system results in a set of circumferential mode levels at each radial location of a microphone inside the duct. Radial basis functions are then least-squares fit to this data to obtain the radial mode amplitudes. For ducts with soft walls and mean flow, the radial basis functions must be numerically computed. The linear companion matrix method is used to obtain both the eigenvalues of interest, without an initial guess, and the radial basis functions. The governing equations allow for the mean flow to have a boundary layer at the wall. In addition, a nonlinear least-squares method is used to adjust the wall impedance to best fit the data in an attempt to use the rotating system as an in-duct wall impedance measurement tool. Simulated and measured data are used to show the effects of wall impedance and mean flow on the computed results.
Demarzo, Arthur P
2009-01-01
Early detection of cardiovascular disease (CVD) could initiate appropriate treatment and prevent progression. This study used impedance cardiography (ICG) waveform analysis with postural change to detect functional CVD in women older than 40 years with no history of CVD and >or=2 of the following risk factors: cigarette smoking, poor diet, physical inactivity, central adiposity, family history of premature CVD, hypertension, and dyslipidemia. A study group of 32 women underwent ICG in standing and supine positions. An age-matched control group had 20 women with an active lifestyle, no risk factors, and no history of CVD. All women in the control group had normal ICG data. All women in the study group had some abnormal ICG data, with 28 (87.5%) having multiple ICG abnormalities. ICG data indicated that 13 (40.6%) had ventricular dysfunction, 14 (43.8%) had high vascular resistive load, and 30 (93.8%) had elevated vascular pulsatile load. The data suggest that subclinical CVD, detectable by ICG, is prevalent in women older than 40 years with multiple risk factors. Abnormal ICG results could expedite the initiation of customized treatment as part of a preventive approach to CVD. (c) 2009 Wiley Periodicals, Inc.
EIT image reconstruction with four dimensional regularization.
Dai, Tao; Soleimani, Manuchehr; Adler, Andy
2008-09-01
Electrical impedance tomography (EIT) reconstructs internal impedance images of the body from electrical measurements on body surface. The temporal resolution of EIT data can be very high, although the spatial resolution of the images is relatively low. Most EIT reconstruction algorithms calculate images from data frames independently, although data are actually highly correlated especially in high speed EIT systems. This paper proposes a 4-D EIT image reconstruction for functional EIT. The new approach is developed to directly use prior models of the temporal correlations among images and 3-D spatial correlations among image elements. A fast algorithm is also developed to reconstruct the regularized images. Image reconstruction is posed in terms of an augmented image and measurement vector which are concatenated from a specific number of previous and future frames. The reconstruction is then based on an augmented regularization matrix which reflects the a priori constraints on temporal and 3-D spatial correlations of image elements. A temporal factor reflecting the relative strength of the image correlation is objectively calculated from measurement data. Results show that image reconstruction models which account for inter-element correlations, in both space and time, show improved resolution and noise performance, in comparison to simpler image models.
Calculation of the coherent synchrotron radiation impedance from a wiggler
NASA Astrophysics Data System (ADS)
Wu, Juhao; Raubenheimer, Tor O.; Stupakov, Gennady V.
2003-04-01
Most studies of coherent synchrotron radiation (CSR) have considered only the radiation from independent dipole magnets. However, in the damping rings of future linear colliders, a large fraction of the radiation power will be emitted in damping wigglers. In this paper, the longitudinal wakefield and impedance due to CSR in a wiggler are derived in the limit of a large wiggler parameter K. After an appropriate scaling, the results can be expressed in terms of universal functions, which are independent of K. Analytical asymptotic results are obtained for the wakefield in the limit of large and small distances, and for the impedance in the limit of small and high frequencies.
Automated analysis of plethysmograms for functional studies of hemodynamics
NASA Astrophysics Data System (ADS)
Zatrudina, R. Sh.; Isupov, I. B.; Gribkov, V. Yu.
2018-04-01
The most promising method for the quantitative determination of cardiovascular tone indicators and of cerebral hemodynamics indicators is the method of impedance plethysmography. The accurate determination of these indicators requires the correct identification of the characteristic points in the thoracic impedance plethysmogram and the cranial impedance plethysmogram respectively. An algorithm for automatic analysis of these plethysmogram is presented. The algorithm is based on the hard temporal relationships between the phases of the cardiac cycle and the characteristic points of the plethysmogram. The proposed algorithm does not require estimation of initial data and selection of processing parameters. Use of the method on healthy subjects showed a very low detection error of characteristic points.
NASA Astrophysics Data System (ADS)
Choi, Jongwan; Kim, Felix Sunjoo
2018-03-01
We studied the influence of photoanode thickness on the photovoltaic characteristics and impedance responses of the dye-sensitized solar cells based on a ruthenium dye containing a hexyloxyl-substituted carbazole unit (Ru-HCz). As the thickness of photoanode increases from 4.2 μm to 14.8 μm, the dye-loading amount and the efficiency increase. The device with thicker photoanode shows a decrease in the efficiency due to the higher probability of recombination of electron-hole pairs before charge extraction. We also analyzed the electron-transfer and recombination characteristics as a function of photoanode thickness through detailed electrochemical impedance spectroscopy analysis.
Study on the Carbonation Behavior of Cement Mortar by Electrochemical Impedance Spectroscopy
Dong, Biqin; Qiu, Qiwen; Xiang, Jiaqi; Huang, Canjie; Xing, Feng; Han, Ningxu
2014-01-01
A new electrochemical model has been carefully established to explain the carbonation behavior of cement mortar, and the model has been validated by the experimental results. In fact, it is shown by this study that the electrochemical impedance behavior of mortars varies in the process of carbonation. With the cement/sand ratio reduced, the carbonation rate reveals more remarkable. The carbonation process can be quantitatively accessed by a parameter, which can be obtained by means of the electrochemical impedance spectroscopy (EIS)-based electrochemical model. It has been found that the parameter is a function of carbonation depth and of carbonation time. Thereby, prediction of carbonation depth can be achieved. PMID:28788452
Study on the Carbonation Behavior of Cement Mortar by Electrochemical Impedance Spectroscopy.
Dong, Biqin; Qiu, Qiwen; Xiang, Jiaqi; Huang, Canjie; Xing, Feng; Han, Ningxu
2014-01-03
A new electrochemical model has been carefully established to explain the carbonation behavior of cement mortar, and the model has been validated by the experimental results. In fact, it is shown by this study that the electrochemical impedance behavior of mortars varies in the process of carbonation. With the cement/sand ratio reduced, the carbonation rate reveals more remarkable. The carbonation process can be quantitatively accessed by a parameter, which can be obtained by means of the electrochemical impedance spectroscopy (EIS)-based electrochemical model. It has been found that the parameter is a function of carbonation depth and of carbonation time. Thereby, prediction of carbonation depth can be achieved.
Analysis of functional redundancies within the Arabidopsis TCP transcription factor family.
Danisman, Selahattin; van Dijk, Aalt D J; Bimbo, Andrea; van der Wal, Froukje; Hennig, Lars; de Folter, Stefan; Angenent, Gerco C; Immink, Richard G H
2013-12-01
Analyses of the functions of TEOSINTE-LIKE1, CYCLOIDEA, and PROLIFERATING CELL FACTOR1 (TCP) transcription factors have been hampered by functional redundancy between its individual members. In general, putative functionally redundant genes are predicted based on sequence similarity and confirmed by genetic analysis. In the TCP family, however, identification is impeded by relatively low overall sequence similarity. In a search for functionally redundant TCP pairs that control Arabidopsis leaf development, this work performed an integrative bioinformatics analysis, combining protein sequence similarities, gene expression data, and results of pair-wise protein-protein interaction studies for the 24 members of the Arabidopsis TCP transcription factor family. For this, the work completed any lacking gene expression and protein-protein interaction data experimentally and then performed a comprehensive prediction of potential functional redundant TCP pairs. Subsequently, redundant functions could be confirmed for selected predicted TCP pairs by genetic and molecular analyses. It is demonstrated that the previously uncharacterized class I TCP19 gene plays a role in the control of leaf senescence in a redundant fashion with TCP20. Altogether, this work shows the power of combining classical genetic and molecular approaches with bioinformatics predictions to unravel functional redundancies in the TCP transcription factor family.
Analysis of functional redundancies within the Arabidopsis TCP transcription factor family
Danisman, Selahattin; de Folter, Stefan; Immink, Richard G. H.
2013-01-01
Analyses of the functions of TEOSINTE-LIKE1, CYCLOIDEA, and PROLIFERATING CELL FACTOR1 (TCP) transcription factors have been hampered by functional redundancy between its individual members. In general, putative functionally redundant genes are predicted based on sequence similarity and confirmed by genetic analysis. In the TCP family, however, identification is impeded by relatively low overall sequence similarity. In a search for functionally redundant TCP pairs that control Arabidopsis leaf development, this work performed an integrative bioinformatics analysis, combining protein sequence similarities, gene expression data, and results of pair-wise protein–protein interaction studies for the 24 members of the Arabidopsis TCP transcription factor family. For this, the work completed any lacking gene expression and protein–protein interaction data experimentally and then performed a comprehensive prediction of potential functional redundant TCP pairs. Subsequently, redundant functions could be confirmed for selected predicted TCP pairs by genetic and molecular analyses. It is demonstrated that the previously uncharacterized class I TCP19 gene plays a role in the control of leaf senescence in a redundant fashion with TCP20. Altogether, this work shows the power of combining classical genetic and molecular approaches with bioinformatics predictions to unravel functional redundancies in the TCP transcription factor family. PMID:24129704
Lutchen, K R
1990-08-01
A sensitivity analysis based on weighted least-squares regression is presented to evaluate alternative methods for fitting lumped-parameter models to respiratory impedance data. The goal is to maintain parameter accuracy simultaneously with practical experiment design. The analysis focuses on predicting parameter uncertainties using a linearized approximation for joint confidence regions. Applications are with four-element parallel and viscoelastic models for 0.125- to 4-Hz data and a six-element model with separate tissue and airway properties for input and transfer impedance data from 2-64 Hz. The criterion function form was evaluated by comparing parameter uncertainties when data are fit as magnitude and phase, dynamic resistance and compliance, or real and imaginary parts of input impedance. The proper choice of weighting can make all three criterion variables comparable. For the six-element model, parameter uncertainties were predicted when both input impedance and transfer impedance are acquired and fit simultaneously. A fit to both data sets from 4 to 64 Hz could reduce parameter estimate uncertainties considerably from those achievable by fitting either alone. For the four-element models, use of an independent, but noisy, measure of static compliance was assessed as a constraint on model parameters. This may allow acceptable parameter uncertainties for a minimum frequency of 0.275-0.375 Hz rather than 0.125 Hz. This reduces data acquisition requirements from a 16- to a 5.33- to 8-s breath holding period. These results are approximations, and the impact of using the linearized approximation for the confidence regions is discussed.
Systematic errors of EIT systems determined by easily-scalable resistive phantoms.
Hahn, G; Just, A; Dittmar, J; Hellige, G
2008-06-01
We present a simple method to determine systematic errors that will occur in the measurements by EIT systems. The approach is based on very simple scalable resistive phantoms for EIT systems using a 16 electrode adjacent drive pattern. The output voltage of the phantoms is constant for all combinations of current injection and voltage measurements and the trans-impedance of each phantom is determined by only one component. It can be chosen independently from the input and output impedance, which can be set in order to simulate measurements on the human thorax. Additional serial adapters allow investigation of the influence of the contact impedance at the electrodes on resulting errors. Since real errors depend on the dynamic properties of an EIT system, the following parameters are accessible: crosstalk, the absolute error of each driving/sensing channel and the signal to noise ratio in each channel. Measurements were performed on a Goe-MF II EIT system under four different simulated operational conditions. We found that systematic measurement errors always exceeded the error level of stochastic noise since the Goe-MF II system had been optimized for a sufficient signal to noise ratio but not for accuracy. In time difference imaging and functional EIT (f-EIT) systematic errors are reduced to a minimum by dividing the raw data by reference data. This is not the case in absolute EIT (a-EIT) where the resistivity of the examined object is determined on an absolute scale. We conclude that a reduction of systematic errors has to be one major goal in future system design.
Magnetoacoustic tomographic imaging of electrical impedance with magnetic induction
NASA Astrophysics Data System (ADS)
Xia, Rongmin; Li, Xu; He, Bin
2007-08-01
Magnetoacoustic tomography with magnetic induction (MAT-MI) is a recently introduced method for imaging tissue electrical impedance properties by integrating magnetic induction and ultrasound measurements. In the present study, the authors have developed a focused cylindrical scanning mode MAT-MI system and the corresponding reconstruction algorithms. Using this system, they demonstrated a three-dimensional MAT-MI imaging approach in a physical phantom, with cylindrical scanning combined with ultrasound focusing, and the ability of MAT-MI in imaging electrical conductivity properties of biological tissue.
Impedance Matched Absorptive Thermal Blocking Filters
NASA Technical Reports Server (NTRS)
Wollack, E. J.; Chuss, D. T.; U-Yen, K.; Rostem, K.
2014-01-01
We have designed, fabricated and characterized absorptive thermal blocking filters for cryogenic microwave applications. The transmission line filter's input characteristic impedance is designed to match 50 Omega and its response has been validated from 0-to-50GHz. The observed return loss in the 0-to-20GHz design band is greater than 20 dB and shows graceful degradation with frequency. Design considerations and equations are provided that enable this approach to be scaled and modified for use in other applications.
Impedance Matched Absorptive Thermal Blocking Filters
NASA Technical Reports Server (NTRS)
Wollack, E. J.; Chuss, D. T.; Rostem, K.; U-Yen, K.
2014-01-01
We have designed, fabricated and characterized absorptive thermal blocking filters for cryogenic microwave applications. The transmission line filter's input characteristic impedance is designed to match 50O and its response has been validated from 0-to-50GHz. The observed return loss in the 0-to-20GHz design band is greater than 20 dB and shows graceful degradation with frequency. Design considerations and equations are provided that enable this approach to be scaled and modified for use in other applications.
Thriving and Not Just Surviving: New Directions for Tomorrow's Performance-Improvement Managers.
ERIC Educational Resources Information Center
Kaufman, Roger
2000-01-01
Examines popular approaches to performance and organizational improvement to see what flaws they contain and how continued practice will impede progress. Discusses benchmarking; quality management/continuous improvement; needs assessment; training; downsizing; reengineering; system(s) approach; and strategic planning. Describes the Organizational…
Schmid, Thomas; Bogdan, Martin; Günzel, Dorothee
2013-01-01
Quantifying changes in partial resistances of epithelial barriers in vitro is a challenging and time-consuming task in physiology and pathophysiology. Here, we demonstrate that electrical properties of epithelial barriers can be estimated reliably by combining impedance spectroscopy measurements, mathematical modeling and machine learning algorithms. Conventional impedance spectroscopy is often used to estimate epithelial capacitance as well as epithelial and subepithelial resistance. Based on this, the more refined two-path impedance spectroscopy makes it possible to further distinguish transcellular and paracellular resistances. In a next step, transcellular properties may be further divided into their apical and basolateral components. The accuracy of these derived values, however, strongly depends on the accuracy of the initial estimates. To obtain adequate accuracy in estimating subepithelial and epithelial resistance, artificial neural networks were trained to estimate these parameters from model impedance spectra. Spectra that reflect behavior of either HT-29/B6 or IPEC-J2 cells as well as the data scatter intrinsic to the used experimental setup were created computationally. To prove the proposed approach, reliability of the estimations was assessed with both modeled and measured impedance spectra. Transcellular and paracellular resistances obtained by such neural network-enhanced two-path impedance spectroscopy are shown to be sufficiently reliable to derive the underlying apical and basolateral resistances and capacitances. As an exemplary perturbation of pathophysiological importance, the effect of forskolin on the apical resistance of HT-29/B6 cells was quantified. PMID:23840862
Design of current source for multi-frequency simultaneous electrical impedance tomography
NASA Astrophysics Data System (ADS)
Han, Bing; Xu, Yanbin; Dong, Feng
2017-09-01
Multi-frequency electrical impedance tomography has been evolving from the frequency-sweep approach to the multi-frequency simultaneous measurement technique which can reduce measuring time and will be increasingly attractive for time-varying biological applications. The accuracy and stability of the current source are the key factors determining the quality of the image reconstruction. This article presents a field programmable gate array-based current source for a multi-frequency simultaneous electrical impedance tomography system. A novel current source circuit was realized by combining the classic current mirror based on the feedback amplifier AD844 with a differential topology. The optimal phase offsets of harmonic sinusoids were obtained through the crest factor analysis. The output characteristics of this current source were evaluated by simulation and actual measurement. The results include the following: (1) the output impedance was compared with one of the Howland pump circuit in simulation, showing comparable performance at low frequencies. However, the proposed current source makes lower demands for resistor tolerance but performs even better at high frequencies. (2) The output impedance in actual measurement below 200 kHz is above 1.3 MΩ and can reach 250 KΩ up to 1 MHz. (3) An experiment based on a biological RC model has been implemented. The mean error for the demodulated impedance amplitude and phase are 0.192% and 0.139°, respectively. Therefore, the proposed current source is wideband, biocompatible, and high precision, which demonstrates great potential to work as a sub-system in the multi-frequency electrical impedance tomography system.
NASA Astrophysics Data System (ADS)
Rabiei, Masoud; Sheldon, Jeremy; Palmer, Carl
2012-04-01
The applicability of Electro-Mechanical Impedance (EMI) approach to damage detection, localization and quantification in a mobile bridge structure is investigated in this paper. The developments in this paper focus on assessing the health of Armored Vehicle Launched Bridges (AVLBs). Specifically, two key failure mechanisms of the AVLB to be monitored were fatigue crack growth and damaged (loose) rivets (bolts) were identified. It was shown through experiment that bolt damage (defined here as different torque levels applied to bolts) can be detected, quantified and located using a network of lead zirconate titanate (PZT) transducers distributed on the structure. It was also shown that cracks of various sizes can be detected and quantified using the EMI approach. The experiments were performed on smaller laboratory specimens as well as full size bridge-like components that were built as part of this research. The effects of various parameters such as transducer type and size on the performance of the proposed health assessment approach were also investigated.
Impedance matched thin metamaterials make metals absorbing.
Mattiucci, N; Bloemer, M J; Aközbek, N; D'Aguanno, G
2013-11-13
Metals are generally considered good reflectors over the entire electromagnetic spectrum up to their plasma frequency. Here we demonstrate an approach to tailor their absorbing characteristics based on the effective metamaterial properties of thin, periodic metallo-dielectric multilayers by exploiting a broadband, inherently non-resonant, surface impedance matching mechanism. Based on this mechanism, we design, fabricate and test omnidirectional, thin (<1 micron), polarization independent, extremely efficient absorbers (in principle being capable to reach A > 99%) over a frequency range spanning from the UV to the IR. Our approach opens new venues to design cost effective materials for many applications such as thermo-photovoltaic energy conversion devices, light harvesting for solar cells, flat panel display, infrared detectors, stray light reduction, stealth and others.
A new approach of active compliance control via fuzzy logic control for multifingered robot hand
NASA Astrophysics Data System (ADS)
Jamil, M. F. A.; Jalani, J.; Ahmad, A.
2016-07-01
Safety is a vital issue in Human-Robot Interaction (HRI). In order to guarantee safety in HRI, a model reference impedance control can be a very useful approach introducing a compliant control. In particular, this paper establishes a fuzzy logic compliance control (i.e. active compliance control) to reduce impact and forces during physical interaction between humans/objects and robots. Exploiting a virtual mass-spring-damper system allows us to determine a desired compliant level by understanding the behavior of the model reference impedance control. The performance of fuzzy logic compliant control is tested in simulation for a robotic hand known as the RED Hand. The results show that the fuzzy logic is a feasible control approach, particularly to control position and to provide compliant control. In addition, the fuzzy logic control allows us to simplify the controller design process (i.e. avoid complex computation) when dealing with nonlinearities and uncertainties.
NASA Astrophysics Data System (ADS)
Zheng, Sifa; Liu, Haitao; Dan, Jiabi; Lian, Xiaomin
2015-05-01
Linear time-invariant assumption for the determination of acoustic source characteristics, the source strength and the source impedance in the frequency domain has been proved reasonable in the design of an exhaust system. Different methods have been proposed to its identification and the multi-load method is widely used for its convenience by varying the load number and impedance. Theoretical error analysis has rarely been referred to and previous results have shown an overdetermined set of open pipes can reduce the identification error. This paper contributes a theoretical error analysis for the load selection. The relationships between the error in the identification of source characteristics and the load selection were analysed. A general linear time-invariant model was built based on the four-load method. To analyse the error of the source impedance, an error estimation function was proposed. The dispersion of the source pressure was obtained by an inverse calculation as an indicator to detect the accuracy of the results. It was found that for a certain load length, the load resistance at the frequency points of one-quarter wavelength of odd multiples results in peaks and in the maximum error for source impedance identification. Therefore, the load impedance of frequency range within the one-quarter wavelength of odd multiples should not be used for source impedance identification. If the selected loads have more similar resistance values (i.e., the same order of magnitude), the identification error of the source impedance could be effectively reduced.
A Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium
Wen, Tao; Wang, Ronghui; Sotero, America; Li, Yanbin
2017-01-01
Salmonella Typhimurium is one of the most dangerous foodborne pathogens and poses a significant threat to human health. The objective of this study was to develop a portable impedance immunosensing system for rapid and sensitive detection of S. Typhimurium in poultry. The developed portable impedance immunosensing system consisted of a gold interdigitated array microelectrode (IDAM), a signal acquisitive interface and a laptop computer with LabVIEW software. The IDAM was first functionalized with 16-Mercaptohexadecanoic acid, and streptavidin was immobilized onto the electrode surface through covalent bonding. Then, biotin-labelled S. Typhimurium-antibody was immobilized onto the IDAM surface. Samples were dropped on the surface of the IDAM and the S. Typhimurium cells in the samples were captured by the antibody on the IDAM. This resulted in impedance changes that were measured and displayed with the LabVIEW software. An equivalent circuit of the immunosensor demonstrated that the largest change in impedance was due to the electron-transfer resistance. The equivalent circuit showed an increase of 35% for the electron-transfer resistance value compared to the negative control. The calibration result indicated that the portable impedance immunosensing system could be used to measure the standard impedance elements, and it had a maximum error of measurement of approximately 13%. For pure culture detection, the system had a linear relationship between the impedance change and the logarithmic value of S. Typhimurium cells ranging from 76 to 7.6 × 106 CFU (colony-forming unit) (50 μL)−1. The immunosensor also had a correlation coefficient of 0.98, and a high specificity for detection of S. Typhimurium cells with a limit of detection (LOD) of 102 CFU (50 μL)−1. The detection time from the moment a sample was introduced to the display of the results was 1 h. To conclude, the portable impedance immunosensing system for detection of S. Typhimurium achieved an LOD that is comparable with commercial electrochemical impedance instruments. The developed impedance immunosensor has advantages in portability, low cost, rapid detection and label-free features showing a great potential for in-field detection of foodborne pathogens. PMID:28846643
A Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium.
Wen, Tao; Wang, Ronghui; Sotero, America; Li, Yanbin
2017-08-28
Salmonella Typhimurium is one of the most dangerous foodborne pathogens and poses a significant threat to human health. The objective of this study was to develop a portable impedance immunosensing system for rapid and sensitive detection of S . Typhimurium in poultry. The developed portable impedance immunosensing system consisted of a gold interdigitated array microelectrode (IDAM), a signal acquisitive interface and a laptop computer with LabVIEW software. The IDAM was first functionalized with 16-Mercaptohexadecanoic acid, and streptavidin was immobilized onto the electrode surface through covalent bonding. Then, biotin-labelled S . Typhimurium -antibody was immobilized onto the IDAM surface. Samples were dropped on the surface of the IDAM and the S . Typhimurium cells in the samples were captured by the antibody on the IDAM. This resulted in impedance changes that were measured and displayed with the LabVIEW software. An equivalent circuit of the immunosensor demonstrated that the largest change in impedance was due to the electron-transfer resistance. The equivalent circuit showed an increase of 35% for the electron-transfer resistance value compared to the negative control. The calibration result indicated that the portable impedance immunosensing system could be used to measure the standard impedance elements, and it had a maximum error of measurement of approximately 13%. For pure culture detection, the system had a linear relationship between the impedance change and the logarithmic value of S . Typhimurium cells ranging from 76 to 7.6 × 10⁶ CFU (colony-forming unit) (50 μL) -1 . The immunosensor also had a correlation coefficient of 0.98, and a high specificity for detection of S . Typhimurium cells with a limit of detection (LOD) of 10² CFU (50 μL) -1 . The detection time from the moment a sample was introduced to the display of the results was 1 h. To conclude, the portable impedance immunosensing system for detection of S . Typhimurium achieved an LOD that is comparable with commercial electrochemical impedance instruments. The developed impedance immunosensor has advantages in portability, low cost, rapid detection and label-free features showing a great potential for in-field detection of foodborne pathogens.
2004-01-01
nerve stimulation combined with an inspiratory impedance threshold in a pig model of hemorrhagic shock. Crit Care Med 2003; 31:1197–1202 16. Coast JR...training. Because of the po- tential effects on cardiovascular function, sub- jects refrained from exercise and stimulants such as caffeine and other...controlled trial. Setting: Laboratory. Subjects: Ten women and ten men. Interventions: We measured hemodynamic and respiratory re- sponses during two
Electromagnetic properties of thin-film transformer-coupled superconducting tunnel junctions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finnegan, T.F.; Lacquaniti, V.; Vaglio, R.
1981-09-01
Multisection superconducting microstrip transformers with designed output impedances below 0.1 ..cap omega.. have been fabricated via precise photolithographic techniques to investigate the electromagnetic properties of Nb-Nb oxide-Pb tunnel junctions. The low-impedance transformer sections incorporate a rf sputtered thin-film Ta-oxide dielectric, and the reproducible external coupling achievable with this type of geometry makes possible the systematic investigation of electromagnetic device parameters as a function of tunneling oxide thickness.
Dual-band reactively loaded microstrip antenna
NASA Technical Reports Server (NTRS)
Richards, W. F.; Long, S. A.; Davidson, S. E.
1985-01-01
A previously derived theory is applied to a microstrip antenna with a reactive load to produce a dual-band radiator. A model consisting of a rectangular patch radiator loaded with a variable length short-circuited coaxial stub was investigated experimentally. Comparisons of theoretical predictions and experimental data are made for the impedance and resonant frequencies as a function of the position of the load, the length of the stub, and the characteristic impedance of the stub.
The significance of cell-related challenges in the clinical application of tissue engineering.
Almela, Thafar; Brook, Ian M; Moharamzadeh, Keyvan
2016-12-01
Tissue engineering is increasingly being recognized as a new approach that could alleviate the burden of tissue damage currently managed with transplants or synthetic devices. Making this novel approach available in the future for patients who would potentially benefit is largely dependent on understanding and addressing all those factors that impede the translation of this technology to the clinic. Cell-associated factors in particular raise many challenges, including those related to cell sources, up- and downstream techniques, preservation, and the creation of in vitro microenvironments that enable cells to grow and function as far as possible as they would in vivo. This article highlights the main confounding issues associated with cells in tissue engineering and how these issues may hinder the advancement of therapeutic tissue engineering. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 3157-3163, 2016. © 2016 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Negrello, Camille; Gosselet, Pierre; Rey, Christian
2018-05-01
An efficient method for solving large nonlinear problems combines Newton solvers and Domain Decomposition Methods (DDM). In the DDM framework, the boundary conditions can be chosen to be primal, dual or mixed. The mixed approach presents the advantage to be eligible for the research of an optimal interface parameter (often called impedance) which can increase the convergence rate. The optimal value for this parameter is often too expensive to be computed exactly in practice: an approximate version has to be sought for, along with a compromise between efficiency and computational cost. In the context of parallel algorithms for solving nonlinear structural mechanical problems, we propose a new heuristic for the impedance which combines short and long range effects at a low computational cost.
Estimating surface acoustic impedance with the inverse method.
Piechowicz, Janusz
2011-01-01
Sound field parameters are predicted with numerical methods in sound control systems, in acoustic designs of building and in sound field simulations. Those methods define the acoustic properties of surfaces, such as sound absorption coefficients or acoustic impedance, to determine boundary conditions. Several in situ measurement techniques were developed; one of them uses 2 microphones to measure direct and reflected sound over a planar test surface. Another approach is used in the inverse boundary elements method, in which estimating acoustic impedance of a surface is expressed as an inverse boundary problem. The boundary values can be found from multipoint sound pressure measurements in the interior of a room. This method can be applied to arbitrarily-shaped surfaces. This investigation is part of a research programme on using inverse methods in industrial room acoustics.
Smart roadside initiative gap analysis : target functionality and gap analysis.
DOT National Transportation Integrated Search
2015-02-01
This document summarizes the target functionality for the Smart Roadside Initiative, as well as the operational, institutional, and technical gaps that currently impede the deployment of three of its operational scenarios (electronic mainline s...
Ferreira, J; Seoane, F; Lindecrantz, K
2013-01-01
Personalised Health Systems (PHS) that could benefit the life quality of the patients as well as decreasing the health care costs for society among other factors are arisen. The purpose of this paper is to study the capabilities of the System-on-Chip Impedance Network Analyser AD5933 performing high speed single frequency continuous bioimpedance measurements. From a theoretical analysis, the minimum continuous impedance estimation time was determined, and the AD5933 with a custom 4-Electrode Analog Front-End (AFE) was used to experimentally determine the maximum continuous impedance estimation frequency as well as the system impedance estimation error when measuring a 2R1C electrical circuit model. Transthoracic Electrical Bioimpedance (TEB) measurements in a healthy subject were obtained using 3M gel electrodes in a tetrapolar lateral spot electrode configuration. The obtained TEB raw signal was filtered in MATLAB to obtain the respiration and cardiogenic signals, and from the cardiogenic signal the impedance derivative signal (dZ/dt) was also calculated. The results have shown that the maximum continuous impedance estimation rate was approximately 550 measurements per second with a magnitude estimation error below 1% on 2R1C-parallel bridge measurements. The displayed respiration and cardiac signals exhibited good performance, and they could be used to obtain valuable information in some plethysmography monitoring applications. The obtained results suggest that the AD5933-based monitor could be used for the implementation of a portable and wearable Bioimpedance plethysmograph that could be used in applications such as Impedance Cardiography. These results combined with the research done in functional garments and textile electrodes might enable the implementation of PHS applications in a relatively short time from now.
NASA Astrophysics Data System (ADS)
Weigand, Maximilian; Kemna, Andreas
2017-02-01
A better understanding of root-soil interactions and associated processes is essential in achieving progress in crop breeding and management, prompting the need for high-resolution and non-destructive characterization methods. To date, such methods are still lacking or restricted by technical constraints, in particular the charactization and monitoring of root growth and function in the field. A promising technique in this respect is electrical impedance tomography (EIT), which utilizes low-frequency (< 1 kHz)- electrical conduction- and polarization properties in an imaging framework. It is well established that cells and cell clusters exhibit an electrical polarization response in alternating electric-current fields due to electrical double layers which form at cell membranes. This double layer is directly related to the electrical surface properties of the membrane, which in turn are influenced by nutrient dynamics (fluxes and concentrations on both sides of the membranes). Therefore, it can be assumed that the electrical polarization properties of roots are inherently related to ion uptake and translocation processes in the root systems. We hereby propose broadband (mHz to hundreds of Hz) multi-frequency EIT as a non-invasive methodological approach for the monitoring and physiological, i.e., functional, characterization of crop root systems. The approach combines the spatial-resolution capability of an imaging method with the diagnostic potential of electrical-impedance spectroscopy. The capability of multi-frequency EIT to characterize and monitor crop root systems was investigated in a rhizotron laboratory experiment, in which the root system of oilseed plants was monitored in a water-filled rhizotron, that is, in a nutrient-deprived environment. We found a low-frequency polarization response of the root system, which enabled the successful delineation of its spatial extension. The magnitude of the overall polarization response decreased along with the physiological decay of the root system due to the stress situation. Spectral polarization parameters, as derived from a pixel-based Debye decomposition analysis of the multi-frequency imaging results, reveal systematic changes in the spatial and spectral electrical response of the root system. In particular, quantified mean relaxation times (of the order of 10 ms) indicate changes in the length scales on which the polarization processes took place in the root system, as a response to the prolonged induced stress situation. Our results demonstrate that broadband EIT is a capable, non-invasive method to image root system extension as well as to monitor changes associated with the root physiological processes. Given its applicability on both laboratory and field scales, our results suggest an enormous potential of the method for the structural and functional imaging of root systems for various applications. This particularly holds for the field scale, where corresponding methods are highly desired but to date are lacking.
Research Challenges And Opportunities To Enhance Ecological Functions In Forested Wetlands
John A. Stanturf; J. Steven Meadows
1994-01-01
Protecting wetland values and functions are important goals for forest managers. Value and function are easy terms to confuse, but they are not interchangeable. Societal values are directly and indirectly associated with ecological functions. For example, forested wetlands may suppress flooding downstream, which is a value. Floodplain forests store water, impede...
Debaty, Guillaume; Metzger, Anja; Rees, Jennifer; McKnite, Scott; Puertas, Laura; Yannopoulos, Demetris; Lurie, Keith
2016-01-01
Objective To improve the likelihood for survival with favorable neurologic function after cardiac arrest, we assessed a new advanced life support approach using active compression-decompression cardiopulmonary resuscitation plus an intrathoracic pressure regulator. Design Prospective animal investigation. Setting Animal laboratory. Subjects Female farm pigs (n = 25) (39 ± 3 kg). Interventions Protocol A: After 12 minutes of untreated ventricular fibrillation, 18 pigs were randomized to group A—3 minutes of basic life support with standard cardiopulmonary resuscitation, defibrillation, and if needed 2 minutes of advanced life support with standard cardiopulmonary resuscitation; group B—3 minutes of basic life support with standard cardiopulmonary resuscitation, defibrillation, and if needed 2 minutes of advanced life support with active compression-decompression plus intrathoracic pressure regulator; and group C—3 minutes of basic life support with active compression-decompression cardiopulmonary resuscitation plus an impedance threshold device, defibrillation, and if needed 2 minutes of advanced life support with active compression-decompression plus intrathoracic pressure regulator. Advanced life support always included IV epinephrine (0.05 μg/kg). The primary endpoint was the 24-hour Cerebral Performance Category score. Protocol B: Myocardial and cerebral blood flow were measured in seven pigs before ventricular fibrillation and then following 6 minutes of untreated ventricular fibrillation during sequential 5 minutes treatments with active compression-decompression plus impedance threshold device, active compression-decompression plus intrathoracic pressure regulator, and active compression-decompression plus intrathoracic pressure regulator plus epinephrine. Measurements and Main Results Protocol A: One of six pigs survived for 24 hours in group A versus six of six in groups B and C (p = 0.002) and Cerebral Performance Category scores were 4.7 ± 0.8, 1.7 ± 0.8, and 1.0 ± 0, respectively (p = 0.001). Protocol B: Brain blood flow was significantly higher with active compression-decompression plus intrathoracic pressure regulator compared with active compression-decompression plus impedance threshold device (0.39 ± 0.23 vs 0.27 ± 0.14 mL/min/g; p = 0.03), whereas differences in myocardial perfusion were not statistically significant (0.65 ± 0.81 vs 0.42 ± 0.36 mL/min/g; p = 0.23). Brain and myocardial blood flow with active compression-decompression plus intrathoracic pressure regulator plus epinephrine were significantly increased versus active compression-decompression plus impedance threshold device (0.40 ± 0.22 and 0.84 ± 0.60 mL/min/g; p = 0.02 for both). Conclusion Advanced life support with active compression-decompression plus intrathoracic pressure regulator significantly improved cerebral perfusion and 24-hour survival with favorable neurologic function. These findings support further evaluation of this new advanced life support methodology in humans. PMID:25756411
Pathogen identification using peptide nanotube biosensors and impedance AFM
NASA Astrophysics Data System (ADS)
Maccuspie, Robert I.
Pathogen identification at highly sensitive levels is crucial to meet urgent needs in fighting the spread of disease or detecting bioterrorism events. Toward that end, a new method for biosensing utilizing fluorescent antibody nanotubes is proposed. Fundamental studies on the self-assembly of these peptide nanotubes are performed, as are applications of aligning these nanotubes on surfaces. As biosensors, these nanotubes incorporate recognition units with antibodies at their ends and fluorescent signaling units at their sidewalls. When viral pathogens were mixed with these antibody nanotubes in solution, the nanotubes rapidly aggregated around the viruses. The size of the aggregates increased as the concentration of viruses increased, as detected by flow cytometry on the order of attomolar concentrations by changes in fluorescence and light scattering intensities. This enabled determination of the concentrations of viruses at trace levels (102 to 106 pfu/mL) within 30 minutes from the receipt of samples to the final quantitative data analysis, as demonstrated on Adenovirus, Herpes Simplex Virus, Influenza, and Vaccinia virus. As another separate approach, impedance AFM is used to study the electrical properties of individual viruses and nanoparticles used as model systems. The design, development, and implementation of the impedance AFM for an Asylum Research platform is described, as well as its application towards studying the impedance of individual nanoparticles as a model system for understanding the fundamental science of how the life cycle of a virus affects its electrical properties. In combination, these approaches fill a pressing need to quantify viruses both rapidly and sensitively.
A comparative study of radiofrequency antennas for Helicon plasma sources
NASA Astrophysics Data System (ADS)
Melazzi, D.; Lancellotti, V.
2015-04-01
Since Helicon plasma sources can efficiently couple power and generate high-density plasma, they have received interest also as spacecraft propulsive devices, among other applications. In order to maximize the power deposited into the plasma, it is necessary to assess the performance of the radiofrequency (RF) antenna that drives the discharge, as typical plasma parameters (e.g. the density) are varied. For this reason, we have conducted a comparative analysis of three Helicon sources which feature different RF antennas, namely, the single-loop, the Nagoya type-III and the fractional helix. These antennas are compared in terms of input impedance and induced current density; in particular, the real part of the impedance constitutes a measure of the antenna ability to couple power into the plasma. The results presented in this work have been obtained through a full-wave approach which (being hinged on the numerical solution of a system of integral equations) allows computing the antenna current and impedance self-consistently. Our findings indicate that certain combinations of plasma parameters can indeed maximize the real part of the input impedance and, thus, the deposited power, and that one of the three antennas analyzed performs best for a given plasma. Furthermore, unlike other strategies which rely on approximate antenna models, our approach enables us to reveal that the antenna current density is not spatially uniform, and that a correlation exists between the plasma parameters and the spatial distribution of the current density.
Quantitative super-resolution imaging of Bruchpilot distinguishes active zone states
NASA Astrophysics Data System (ADS)
Ehmann, Nadine; van de Linde, Sebastian; Alon, Amit; Ljaschenko, Dmitrij; Keung, Xi Zhen; Holm, Thorge; Rings, Annika; Diantonio, Aaron; Hallermann, Stefan; Ashery, Uri; Heckmann, Manfred; Sauer, Markus; Kittel, Robert J.
2014-08-01
The precise molecular architecture of synaptic active zones (AZs) gives rise to different structural and functional AZ states that fundamentally shape chemical neurotransmission. However, elucidating the nanoscopic protein arrangement at AZs is impeded by the diffraction-limited resolution of conventional light microscopy. Here we introduce new approaches to quantify endogenous protein organization at single-molecule resolution in situ with super-resolution imaging by direct stochastic optical reconstruction microscopy (dSTORM). Focusing on the Drosophila neuromuscular junction (NMJ), we find that the AZ cytomatrix (CAZ) is composed of units containing ~137 Bruchpilot (Brp) proteins, three quarters of which are organized into about 15 heptameric clusters. We test for a quantitative relationship between CAZ ultrastructure and neurotransmitter release properties by engaging Drosophila mutants and electrophysiology. Our results indicate that the precise nanoscopic organization of Brp distinguishes different physiological AZ states and link functional diversification to a heretofore unrecognized neuronal gradient of the CAZ ultrastructure.
NASA Astrophysics Data System (ADS)
Kusak, I.; Lunak, M.
2017-09-01
This paper presents basic electric properties of laboratory prepared alkali-activated composite materials on the basis of finely ground granular high furnace slag to which various quantities of carbon nanotubes (CNT) have been added. Impedance spectroscopy in the frequency range from 40 Hz to 1 MHz was used to measure the specimens. Electric resistivity ρ versus frequency and electric resistivity ρ versus CNT content relationships were examined on our specimens R&S ZNC vector analyser with DAK-12 coaxial probe (made by Speag) was used to carry out the measurements at higher frequencies (from 100 MHz to 3 GHz). Electric conductivity σ as a function of the frequency and as a function of the specimen CNT content was studied in this frequency range. Up-to-date instruments and a unique approach have evidently been employed to carry out non-destructive measurement of mortar materials.
Transcranial direct current stimulation for motor recovery of upper limb function after stroke.
Lüdemann-Podubecká, Jitka; Bösl, Kathrin; Rothhardt, Sandra; Verheyden, Geert; Nowak, Dennis Alexander
2014-11-01
Changes in neural processing after stroke have been postulated to impede recovery from stroke. Transcranial direct current stimulation has the potential to alter cortico-spinal excitability and thereby might be beneficial in stroke recovery. We review the pertinent literature prior to 30/09/2013 on transcranial direct current stimulation in promoting motor recovery of the affected upper limb after stroke. We found overall 23 trials (they included 523 participants). All stimulation protocols pride on interhemispheric imbalance model. In a comparative approach, methodology and effectiveness of (a) facilitation of the affected hemisphere, (b) inhibition of the unaffected hemisphere and (c) combined application of transcranial direct current stimulation over the affected and unaffected hemispheres to treat impaired hand function after stroke are presented. Transcranial direct current stimulation is associated with improvement of the affected upper limb after stroke, but current evidence does not support its routine use. Copyright © 2014 Elsevier Ltd. All rights reserved.
Aging and place in long-term care settings: influences on social relationships.
Bonifas, Robin P; Simons, Kelsey; Biel, Barbara; Kramer, Christie
2014-12-01
This article presents results of a qualitative research study that examined how living in a long-term care (LTC) home influences the quality of residents' relationships with peers, family members, and outside friends. Semistructured interviews using a phenomenological approach were conducted with 23 residents of a LTC home. Thematic analysis was employed to illuminate residents' perspectives on the nature of social relationships in this setting. Four key themes were identified that highlight the role of place in social relationships. Residing in a LTC home influences the context of social interactions, impacts their quality and process, clusters individuals with health and functional declines that hinder socialization, and poses structural and cultural barriers that impede social interactions. Health and functional limitations posed the greatest challenge to socialization relative to characteristics of the facility itself. Residents' insights emphasize how personal characteristics influence community culture and the experience of place. © The Author(s) 2014.
Juvenile Fibromyalgia: A Multidisciplinary Approach to Treatment.
Tesher, Melissa S
2015-06-01
A 14-year-old boy presented with months of severe widespread musculoskeletal pain. He was profoundly fatigued and unable to attend school. Laboratory evaluation, including complete blood count, comprehensive metabolic panel, inflammatory markers, and thyroid function, was unrevealing. Physical examination was also normal except for multiple tender points. The patient was diagnosed with juvenile primary fibromyalgia syndrome and referred for multidisciplinary treatment including physical therapy, exercise, and counseling, and his daily functioning gradually improves. Juvenile fibromyalgia is a complex syndrome that often severely limits patients' activities and can impede normal adolescent development. Effective treatment requires an understanding of the biologic, psychologic, and social factors contributing to the perpetuation of chronic pain. The author reviews the diagnostic criteria, pathophysiology, and treatment of juvenile fibromyalgia. Medications, particularly antidepressants and anticonvulsants, can be useful adjuncts to therapy. However, multimodal pain management including intensive physical therapy, exercise, counseling, and sleep hygiene is most effective in treating fibromyalgia. Copyright 2015, SLACK Incorporated.
Automated real-time structure health monitoring via signature pattern recognition
NASA Astrophysics Data System (ADS)
Sun, Fanping P.; Chaudhry, Zaffir A.; Rogers, Craig A.; Majmundar, M.; Liang, Chen
1995-05-01
Described in this paper are the details of an automated real-time structure health monitoring system. The system is based on structural signature pattern recognition. It uses an array of piezoceramic patches bonded to the structure as integrated sensor-actuators, an electric impedance analyzer for structural frequency response function acquisition and a PC for control and graphic display. An assembled 3-bay truss structure is employed as a test bed. Two issues, the localization of sensing area and the sensor temperature drift, which are critical for the success of this technique are addressed and a novel approach of providing temperature compensation using probability correlation function is presented. Due to the negligible weight and size of the solid-state sensor array and its ability to sense incipient-type damage, the system can eventually be implemented on many types of structures such as aircraft, spacecraft, large-span dome roof and steel bridges requiring multilocation and real-time health monitoring.
DIELECTROPHORESIS-BASED MICROFLUIDIC SEPARATION AND DETECTION SYSTEMS
Yang, Jun; Vykoukal, Jody; Noshari, Jamileh; Becker, Frederick; Gascoyne, Peter; Krulevitch, Peter; Fuller, Chris; Ackler, Harold; Hamilton, Julie; Boser, Bernhard; Eldredge, Adam; Hitchens, Duncan; Andrews, Craig
2009-01-01
Diagnosis and treatment of human diseases frequently requires isolation and detection of certain cell types from a complex mixture. Compared with traditional separation and detection techniques, microfluidic approaches promise to yield easy-to-use diagnostic instruments tolerant of a wide range of operating environments and capable of accomplishing automated analyses. These approaches will enable diagnostic advances to be disseminated from sophisticated clinical laboratories to the point-of-care. Applications will include the separation and differential analysis of blood cell subpopulations for host-based detection of blood cell changes caused by disease, infection, or exposure to toxins, and the separation and analysis of surface-sensitized, custom dielectric beads for chemical, biological, and biomolecular targets. Here we report a new particle separation and analysis microsystem that uses dielectrophoretic field-flow fractionation (DEP-FFF). The system consists of a microfluidic chip with integrated sample injector, a DEP-FFF separator, and an AC impedance sensor. We show the design of a miniaturized impedance sensor integrated circuit (IC) with improved sensitivity, a new packaging approach for micro-flumes that features a slide-together compression package and novel microfluidic interconnects, and the design, control, integration and packaging of a fieldable prototype. Illustrative applications will be shown, including the separation of different sized beads and different cell types, blood cell differential analysis, and impedance sensing results for beads, spores and cells. PMID:22025905
Fleerkotte, Bertine M; Koopman, Bram; Buurke, Jaap H; van Asseldonk, Edwin H F; van der Kooij, Herman; Rietman, Johan S
2014-03-04
There is increasing interest in the use of robotic gait-training devices in walking rehabilitation of incomplete spinal cord injured (iSCI) individuals. These devices provide promising opportunities to increase the intensity of training and reduce physical demands on therapists. Despite these potential benefits, robotic gait-training devices have not yet demonstrated clear advantages over conventional gait-training approaches, in terms of functional outcomes. This might be due to the reduced active participation and step-to-step variability in most robotic gait-training strategies, when compared to manually assisted therapy. Impedance-controlled devices can increase active participation and step-to-step variability. The aim of this study was to assess the effect of impedance-controlled robotic gait training on walking ability and quality in chronic iSCI individuals. A group of 10 individuals with chronic iSCI participated in an explorative clinical trial. Participants trained three times a week for eight weeks using an impedance-controlled robotic gait trainer (LOPES: LOwer extremity Powered ExoSkeleton). Primary outcomes were the 10-meter walking test (10 MWT), the Walking Index for Spinal Cord Injury (WISCI II), the six-meter walking test (6 MWT), the Timed Up and Go test (TUG) and the Lower Extremity Motor Scores (LEMS). Secondary outcomes were spatiotemporal and kinematics measures. All participants were tested before, during, and after training and at 8 weeks follow-up. Participants experienced significant improvements in walking speed (0.06 m/s, p = 0.008), distance (29 m, p = 0.005), TUG (3.4 s, p = 0.012), LEMS (3.4, p = 0.017) and WISCI after eight weeks of training with LOPES. At the eight-week follow-up, participants retained the improvements measured at the end of the training period. Significant improvements were also found in spatiotemporal measures and hip range of motion. Robotic gait training using an impedance-controlled robot is feasible in gait rehabilitation of chronic iSCI individuals. It leads to improvements in walking ability, muscle strength, and quality of walking. Improvements observed at the end of the training period persisted at the eight-week follow-up. Slower walkers benefit the most from the training protocol and achieve the greatest relative improvement in speed and walking distance.
2014-01-01
Background There is increasing interest in the use of robotic gait-training devices in walking rehabilitation of incomplete spinal cord injured (iSCI) individuals. These devices provide promising opportunities to increase the intensity of training and reduce physical demands on therapists. Despite these potential benefits, robotic gait-training devices have not yet demonstrated clear advantages over conventional gait-training approaches, in terms of functional outcomes. This might be due to the reduced active participation and step-to-step variability in most robotic gait-training strategies, when compared to manually assisted therapy. Impedance-controlled devices can increase active participation and step-to-step variability. The aim of this study was to assess the effect of impedance-controlled robotic gait training on walking ability and quality in chronic iSCI individuals. Methods A group of 10 individuals with chronic iSCI participated in an explorative clinical trial. Participants trained three times a week for eight weeks using an impedance-controlled robotic gait trainer (LOPES: LOwer extremity Powered ExoSkeleton). Primary outcomes were the 10-meter walking test (10MWT), the Walking Index for Spinal Cord Injury (WISCI II), the six-meter walking test (6MWT), the Timed Up and Go test (TUG) and the Lower Extremity Motor Scores (LEMS). Secondary outcomes were spatiotemporal and kinematics measures. All participants were tested before, during, and after training and at 8 weeks follow-up. Results Participants experienced significant improvements in walking speed (0.06 m/s, p = 0.008), distance (29 m, p = 0.005), TUG (3.4 s, p = 0.012), LEMS (3.4, p = 0.017) and WISCI after eight weeks of training with LOPES. At the eight-week follow-up, participants retained the improvements measured at the end of the training period. Significant improvements were also found in spatiotemporal measures and hip range of motion. Conclusion Robotic gait training using an impedance-controlled robot is feasible in gait rehabilitation of chronic iSCI individuals. It leads to improvements in walking ability, muscle strength, and quality of walking. Improvements observed at the end of the training period persisted at the eight-week follow-up. Slower walkers benefit the most from the training protocol and achieve the greatest relative improvement in speed and walking distance. PMID:24594284
de Bortoli, Nicola; Martinucci, Irene; Savarino, Edoardo; Tutuian, Radu; Frazzoni, Marzio; Piaggi, Paolo; Bertani, Lorenzo; Furnari, Manuele; Franchi, Riccardo; Russo, Salvatore; Bellini, Massimo; Savarino, Vincenzo; Marchi, Santino
2015-06-01
Esophageal impedance measurements have been proposed to indicate the status of the esophageal mucosa, and might be used to study the roles of the impaired mucosal integrity and increased acid sensitivity in patients with heartburn. We compared baseline impedance levels among patients with heartburn who did and did not respond to proton pump inhibitor (PPI) therapy, along with the pathophysiological characteristics of functional heartburn (FH). In a case-control study, we collected data from January to December 2013 on patients with heartburn and normal findings from endoscopy who were not receiving PPI therapy and underwent impedance pH testing at hospitals in Italy. Patients with negative test results were placed on an 8-week course of PPI therapy (84 patients received esomeprazole and 36 patients received pantoprazole). Patients with more than 50% symptom improvement were classified as FH/PPI responders and patients with less than 50% symptom improvement were classified as FH/PPI nonresponders. Patients with hypersensitive esophagus and healthy volunteers served as controls. In all patients and controls, we measured acid exposure time, number of reflux events, baseline impedance, and swallow-induced peristaltic wave indices. FH/PPI responders had higher acid exposure times, numbers of reflux events, and acid refluxes compared with FH/PPI nonresponders (P < .05). Patients with hypersensitive esophagus had mean acid exposure times and numbers of reflux events similar to those of FH/PPI responders. Baseline impedance levels were lower in FH/PPI responders and patients with hypersensitive esophagus, compared with FH/PPI nonresponders and healthy volunteers (P < .001). Swallow-induced peristaltic wave indices were similar between FH/PPI responders and patients with hypersensitive esophagus. Patients with FH who respond to PPI therapy have impedance pH features similar to those of patients with hypersensitive esophagus. Baseline impedance measurements might allow for identification of patients who respond to PPIs but would be classified as having FH based on conventional impedance-pH measurements. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights reserved.
Dong, Jianchen; Song, Zhongchang; Li, Songhai; Gong, Zining; Li, Kuan; Zhang, Peijun; Zhang, Yu; Zhang, Meng
2017-10-01
Acoustic properties of odontocete head tissues, including sound velocity, density, and acoustic impedance, are important parameters to understand dynamics of its echolocation. In this paper, acoustic properties of head tissues from a freshly dead short-finned pilot whale (Globicephala macrorhynchus) were reconstructed using computed tomography (CT) and ultrasound. The animal's forehead soft tissues were cut into 188 ordered samples. Sound velocity, density, and acoustic impedance of each sample were either directly measured or calculated by formula, and Hounsfield Unit values (HUs) were obtained from CT scanning. According to relationships between HUs and sound velocity, HUs and density, as well as HUs and acoustic impedance, distributions of acoustic properties in the head were reconstructed. The inner core in the melon with low-sound velocity and low-density is an evidence for its potential function of sound focusing. The increase in acoustic impedance of forehead tissues from inner core to outer layer may be important for the acoustic impedance matching between the outer layer tissue and seawater. In addition, temperature dependence of sound velocity in soft tissues was also examined. The results provide a guide to the simulation of the sound emission of the short-finned pilot whale.
NASA Astrophysics Data System (ADS)
Hsini, Mohamed; Hamdaoui, Nejeh; Hcini, Sobhi; Bouazizi, Mohamed Lamjed; Zemni, Sadok; Beji, Lotfi
2018-03-01
The effect of Fe-doping at Mn-site on the structural and electrical properties of Nd0.67Ba0.33Mn1-xFexO3 (0 ≤ x ≤ 0.05) perovskites has been investigated. X-ray diffraction patterns show that the structural parameters change slightly due to the fact that the Fe3+ ions replacing the Mn3+ have similar ionic radius. The electrical properties of these samples have been investigated using complex impedance spectroscopy technique. a function of the frequency at different temperatures. When increasing the Fe-content, a decrease of dc conductivity was observed throughout the whole explored temperature range and the deduced activation energy values are found to increase from 128 meV for x = 0 to 166 meV for x = 0.05. The curves of the imaginary part of impedance (Z″) show the presence of relaxation phenomenon in our samples. The complex impedance spectra show semicircle arcs at different temperatures and an equivalent circuit of the type of Rg + (Rgb//Cgb) has been proposed to explain the impedance results.
NASA Technical Reports Server (NTRS)
Rick, R. C.; Lushbaugh, C. C.; Mcdow, E.; Frome, E.
1972-01-01
Changes in respiratory variance revealed by power spectral analysis of the pulmonary impedance pneumogram can be used to detect and measure stresses directly or indirectly affecting human respiratory function. When gastrointestinal distress occurred during a series of 5 total-body exposures of 30 R at a rate of 1.5 R/min, it was accompanied by typical shifts in pulmonary impedance power spectra. These changes did not occur after protracted exposure of 250 R (30 R daily) at 1.5 R/hr that failed to cause radiation sickness. This system for quantitating respiratory effort can also be used to detect alterations in one's ability to perform under controlled exercise conditions.
Brandão, Eric; Flesch, Rodolfo C C; Lenzi, Arcanjo; Flesch, Carlos A
2011-07-01
The pressure-particle velocity (PU) impedance measurement technique is an experimental method used to measure the surface impedance and the absorption coefficient of acoustic samples in situ or under free-field conditions. In this paper, the measurement uncertainty of the the absorption coefficient determined using the PU technique is explored applying the Monte Carlo method. It is shown that because of the uncertainty, it is particularly difficult to measure samples with low absorption and that difficulties associated with the localization of the acoustic centers of the sound source and the PU sensor affect the quality of the measurement roughly to the same extent as the errors in the transfer function between pressure and particle velocity do. © 2011 Acoustical Society of America
A New First-Principles Calculation of Field-Dependent RF Surface Impedance of BCS Superconductor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiao, Binping; Reece, Charles E.
2014-02-01
There is a need to understand the intrinsic limit of radiofrequency (RF) surface impedance that determines the performance of superconducting RF cavities in particle accelerators. Here we present a field-dependent derivation of Mattis-Bardeen theory of the RF surface impedance of BCS superconductors based on the shifted density of states resulting from coherently moving Cooper pairs. Our theoretical prediction of the effective BCS RF surface resistance (Rs) of niobium as a function of peak surface magnetic field amplitude agrees well with recently reported record low loss resonant cavity measurements from JLab and FNAL with carefully, yet differently, prepared niobium material. Themore » surprising reduction in resistance with increasing field is explained to be an intrinsic effect.« less
Eddy current characterization of magnetic treatment of materials
NASA Technical Reports Server (NTRS)
Chern, E. James
1992-01-01
Eddy current impedance measuring methods have been applied to study the effect that magnetically treated materials have on service life extension. Eddy current impedance measurements have been performed on Nickel 200 specimens that have been subjected to many mechanical and magnetic engineering processes: annealing, applied strain, magnetic field, shot peening, and magnetic field after peening. Experimental results have demonstrated a functional relationship between coil impedance, resistance and reactance, and specimens subjected to various engineering processes. It has shown that magnetic treatment does induce changes in a material's electromagnetic properties and does exhibit evidence of stress relief. However, further fundamental studies are necessary for a thorough understanding of the exact mechanism of the magnetic-field processing effect on machine tool service life.
NASA Astrophysics Data System (ADS)
Novak, A.; Honzik, P.; Bruneau, M.
2017-08-01
Miniaturized vibrating MEMS devices, active (receivers or emitters) or passive devices, and their use for either new applications (hearing, meta-materials, consumer devices,…) or metrological purposes under non-standard conditions, are involved today in several acoustic domains. More in-depth characterisation than the classical ones available until now are needed. In this context, the paper presents analytical and numerical approaches for describing the behaviour of three kinds of planar micro-beams of rectangular shape (suspended rigid or clamped elastic planar beam) loaded by a backing cavity or a fluid-gap, surrounded by very thin slits, and excited by an incident acoustic field. The analytical approach accounts for the coupling between the vibrating structure and the acoustic field in the backing cavity, the thermal and viscous diffusion processes in the boundary layers in the slits and the cavity, the modal behaviour for the vibrating structure, and the non-uniformity of the acoustic field in the backing cavity which is modelled in using an integral formulation with a suitable Green's function. Benchmark solutions are proposed in terms of beam motion (from which the sensitivity, input impedance, and pressure transfer function can be calculated). A numerical implementation (FEM) is handled against which the analytical results are tested.
Wang, Hao; Liu, Kan; Chen, Kuan-Ju; Lu, Yujie; Wang, Shutao; Lin, Wei-Yu; Guo, Feng; Kamei, Ken-ichiro; Chen, Yi-Chun; Ohashi, Minori; Wang, Mingwei; Garcia, Mitch André; Zhao, Xing-Zhong; Shen, Clifton K.-F.; Tseng, Hsian-Rong
2010-01-01
Nanoparticles are regarded as promising transfection reagents for effective and safe delivery of nucleic acids into specific type of cells or tissues providing an alternative manipulation/therapy strategy to viral gene delivery. However, the current process of searching novel delivery materials is limited due to conventional low-throughput and time-consuming multistep synthetic approaches. Additionally, conventional approaches are frequently accompanied with unpredictability and continual optimization refinements, impeding flexible generation of material diversity creating a major obstacle to achieving high transfection performance. Here we have demonstrated a rapid developmental pathway toward highly efficient gene delivery systems by leveraging the powers of a supramolecular synthetic approach and a custom-designed digital microreactor. Using the digital microreactor, broad structural/functional diversity can be programmed into a library of DNA-encapsulated supramolecular nanoparticles (DNA⊂SNPs) by systematically altering the mixing ratios of molecular building blocks and a DNA plasmid. In vitro transfection studies with DNA⊂SNPs library identified the DNA⊂SNPs with the highest gene transfection efficiency, which can be attributed to cooperative effects of structures and surface chemistry of DNA⊂SNPs. We envision such a rapid developmental pathway can be adopted for generating nanoparticle-based vectors for delivery of a variety of loads. PMID:20925389
Measurement of bio-impedance with a smart needle to confirm percutaneous kidney access.
Hernandez, D J; Sinkov, V A; Roberts, W W; Allaf, M E; Patriciu, A; Jarrett, T W; Kavoussi, L R; Stoianovici, D
2001-10-01
The traditional method of percutaneous renal access requires freehand needle placement guided by C-arm fluoroscopy, ultrasonography, or computerized tomography. This approach provides limited objective means for verifying successful access. We developed an impedance based percutaneous Smart Needle system and successfully used it to confirm collecting system access in ex vivo porcine kidneys. The Smart Needle consists of a modified 18 gauge percutaneous access needle with the inner stylet electrically insulated from the outer sheath. Impedance is measured between the exposed stylet tip and sheath using Model 4275 LCR meter (Hewlett-Packard, Sunnyvale, California). An ex vivo porcine kidney was distended by continuous gravity infusion of 100 cm. water saline from a catheter passed through the parenchyma into the collecting system. The Smart Needle was gradually inserted into the kidney to measure depth precisely using a robotic needle placement system, while impedance was measured continuously. The Smart Needle was inserted 4 times in each of 4 kidneys. When the needle penetrated the distended collecting system in 11 of 16 attempts, a characteristic sharp drop in resistivity was noted from 1.9 to 1.1 ohm m. Entry into the collecting system was confirmed by removing the stylet and observing fluid flow from the sheath. This characteristic impedance change was observed only at successful entry into the collecting system. A characteristic sharp drop in impedance signifies successful entry into the collecting system. The Smart Needle system may prove useful for percutaneous kidney access.
Detection of Alzheimer’s disease amyloid-beta plaque deposition by deep brain impedance profiling
NASA Astrophysics Data System (ADS)
Béduer, Amélie; Joris, Pierre; Mosser, Sébastien; Fraering, Patrick C.; Renaud, Philippe
2015-04-01
Objective. Alzheimer disease (AD) is the most common form of neurodegenerative disease in elderly people. Toxic brain amyloid-beta (Aß) aggregates and ensuing cell death are believed to play a central role in the pathogenesis of the disease. In this study, we investigated if we could monitor the presence of these aggregates by performing in situ electrical impedance spectroscopy measurements in AD model mice brains. Approach. In this study, electrical impedance spectroscopy measurements were performed post-mortem in APPPS1 transgenic mice brains. This transgenic model is commonly used to study amyloidogenesis, a pathological hallmark of AD. We used flexible probes with embedded micrometric electrodes array to demonstrate the feasibility of detecting senile plaques composed of Aß peptides by localized impedance measurements. Main results. We particularly focused on deep brain structures, such as the hippocampus. Ex vivo experiments using brains from young and old APPPS1 mice lead us to show that impedance measurements clearly correlate with the percentage of Aβ plaque load in the brain tissues. We could monitor the effects of aging in the AD APPPS1 mice model. Significance. We demonstrated that a localized electrical impedance measurement constitutes a valuable technique to monitor the presence of Aβ-plaques, which is complementary with existing imaging techniques. This method does not require prior Aβ staining, precluding the risk of variations in tissue uptake of dyes or tracers, and consequently ensuring reproducible data collection.
Navy Collaborative Integrated Information Technology Initiative (NAVCIITI)
2004-09-01
We investigated a new type of antenna array consisting of sub- elements that are excited together to form the primary element. All of the sub...elements of the array are excited for the highest operating band. Only the primary elements are excited for the low frequency band. This fractal geometry has...fully active array. The fully active input impedance is the input impedance of an element in an array when all elements are excited . It is a function
NASA Astrophysics Data System (ADS)
Ko, Yee Song; Cuervo-Reyes, Eduardo; Nüesch, Frank A.; Opris, Dorina M.
2016-04-01
The dielectric relaxation processes of polymethyl methacrylates that have been functionalized with Disperse Red 1 (DR1) in the side chain (DR1-co-MMA) were studied with temperature dependent impedance spectroscopy and thermally stimulated depolarization current (TSDC) techniques. Copolymers with dipole contents which varied between 10 mol% and 70 mol% were prepared. All samples showed dipole relaxations above the structural-glass transition temperature (Tg). The β-relaxation of the methyl methacrylate (MMA) repeating unit was most visible in DR1(10%)-co-MMA and rapidly vanishes with higher dipole contents. DSC data reveal an increase of the Tg by 20 °C to 125°C with the inclusion of the dipole into the polymethyl methacrylate (PMMA) as side chain. The impedance data of samples with several DR1 concentrations, taken at several temperatures above Tg, have been fitted with the Havriliak-Negami (HN) function. In all cases, the fits reveal a dielectric response that corresponds to power-law dipolar relaxations. TSDC measurements show that the copolymer can be poled, and that the induced polarization can be frozen by lowering the temperature well below the glass transition. Relaxation strengths ΔƐ estimated by integrating the depolarization current are similar to those obtained from the impedance data, confirming the efficient freezing of the dipoles in the structural glass state.
de Vries, Gabe; Hees, Hiske L; Koeter, Maarten W J; Lagerveld, Suzanne E; Schene, Aart H
2014-01-01
The purpose of the present study was to explore various stakeholder perspectives regarding factors that impede return-to-work (RTW) after long-term sickness absence related to major depressive disorder (MDD). Concept mapping was used to explore employees', supervisors' and occupational physicians' perspectives on these impeding factors. Nine perceived themes, grouped in three meta-clusters were found that might impede RTW: Person, (personality / coping problems, symptoms of depression and comorbid (health) problems, employee feels misunderstood, and resuming work too soon), Work (troublesome work situation, too little support at work, and too little guidance at work) and Healthcare (insufficient mental healthcare and insufficient care from occupational physician). All stakeholders regarded personality/coping problems and symptoms of depression as the most important impeding theme. In addition, supervisors emphasized the importance of mental healthcare underestimating the importance of the work environment, while occupational physicians stressed the importance of the lack of safety and support in the work environment. In addition to the reduction of symptoms, more attention is needed on coping with depressive symptoms and personality problems in the work environment support in the work environment and for RTW in mental healthcare, to prevent long term sickness absence.
NASA Astrophysics Data System (ADS)
Uno, Takanori; Ichikawa, Kouji; Mabuchi, Yuichi; Nakamura, Atsushi; Okazaki, Yuji; Asai, Hideki
In this paper, we studied the use of common-mode noise reduction technique for in-vehicle electronic equipment in an actual instrument design. We have improved the circuit model of the common-mode noise that flows to the wire harness to add the effect of a bypass capacitor located near the LSI. We analyzed the improved circuit model using a circuit simulator and verified the effectiveness of the noise reduction condition derived from the circuit model. It was also confirmed that offsetting the impedance mismatch in the PCB section requires to make a circuit constant larger than that necessary for doing the impedance mismatch in the LSI section. An evaluation circuit board comprising an automotive microcomputer was prototyped to experiment on the common-mode noise reduction effect of the board. The experimental results showed the noise reduction effect of the board. The experimental results also revealed that the degree of impedance mismatch in the LSI section can be estimated by using a PCB having a known impedance. We further inquired into the optimization of impedance parameters, which is difficult for actual products at present. To satisfy the noise reduction condition composed of numerous parameters, we proposed a design method using an optimization algorithm and an electromagnetic field simulator, and confirmed its effectiveness.
NASA Astrophysics Data System (ADS)
Vitarelli, Michael J.; Talaga, David S.
2013-09-01
Single solid-state nanopores find increasing use for electrical detection and/or manipulation of macromolecules. These applications exploit the changes in signals due to the geometry and electrical properties of the molecular species found within the nanopore. The sensitivity and resolution of such measurements are also influenced by the geometric and electrical properties of the nanopore. This paper continues the development of an analytical theory to predict the electrochemical impedance spectra of nanopores by including the influence of the presence of an unfolded protein using the variable topology finite Warburg impedance model previously published by the authors. The local excluded volume of, and charges present on, the segment of protein sampled by the nanopore are shown to influence the shape and peak frequency of the electrochemical impedance spectrum. An analytical theory is used to relate the capacitive response of the electrical double layer at the surface of the protein to both the charge density at the protein surface and the more commonly measured zeta potential. Illustrative examples show how the theory predicts that the varying sequential regions of surface charge density and excluded volume dictated by the protein primary structure may allow for an impedance-based approach to identifying unfolded proteins.
Imaging fast electrical activity in the brain with electrical impedance tomography
Aristovich, Kirill Y.; Packham, Brett C.; Koo, Hwan; Santos, Gustavo Sato dos; McEvoy, Andy; Holder, David S.
2016-01-01
Imaging of neuronal depolarization in the brain is a major goal in neuroscience, but no technique currently exists that could image neural activity over milliseconds throughout the whole brain. Electrical impedance tomography (EIT) is an emerging medical imaging technique which can produce tomographic images of impedance changes with non-invasive surface electrodes. We report EIT imaging of impedance changes in rat somatosensory cerebral cortex with a resolution of 2 ms and < 200 μm during evoked potentials using epicortical arrays with 30 electrodes. Images were validated with local field potential recordings and current source-sink density analysis. Our results demonstrate that EIT can image neural activity in a volume 7 × 5 × 2 mm in somatosensory cerebral cortex with reduced invasiveness, greater resolution and imaging volume than other methods. Modeling indicates similar resolutions are feasible throughout the entire brain so this technique, uniquely, has the potential to image functional connectivity of cortical and subcortical structures. PMID:26348559
Nondestructive evaluation techniques for nickel-cadmium aerospace battery cells
NASA Technical Reports Server (NTRS)
Haak, R.; Tench, D.
1982-01-01
The ac impedance characteristics of Ni-Cd cells as an in-situ, nondestructive means of determining cell lifetime, particularly with respect to the probability of premature failure were evaluated. Emphasis was on evaluating Ni-Cd cell impedance over a wide frequency range (10,000 to 0.0004 Hz) as the cells were subjected to charge/discharge cycle testing. The results indicate that cell degradation is reflected in the low frequency (Warburg) impedance characteristics associated with diffusion processes. The Warburg slope (W) was found to steadily increase as a function of cell aging for completely discharged cells. In addition, based on data for two cells, a high or rapidly increasing value for W signals imminent cell failure by one mechanism. Degradation by another mechanism is apparently reflected in a fall-off (roll-over) of W at lower frequencies. As a secondary result, the frequency dependence of the absolute cell impedance at low frequencies (5 - 500 mHz) was found to be a good indication of the cell state-of-charge.
NASA Technical Reports Server (NTRS)
Dewberry, B.
2000-01-01
Electrical impedance spectrometry involves measurement of the complex resistance of a load at multiple frequencies. With this information in the form of impedance magnitude and phase, or resistance and reactance, basic structure or function of the load can be estimated. The "load" targeted for measurement and estimation in this study consisted of the water-bearing tissues of the human calf. It was proposed and verified that by measuring the electrical impedance of the human calf and fitting this data to a model of fluid compartments, the lumped-model volume of intracellular and extracellular spaces could be estimated, By performing this estimation over time, the volume dynamics during application of stimuli which affect the direction of gravity can be viewed. The resulting data can form a basis for further modeling and verification of cardiovascular and compartmental modeling of fluid reactions to microgravity as well as countermeasures to the headward shift of fluid during head-down tilt or spaceflight.
NASA Technical Reports Server (NTRS)
Cowings, Patricia S.; Naifeh, Karen; Thrasher, Chet
1988-01-01
This report contains the source code and documentation for a computer program used to process impedance cardiography data. The cardiodynamic measures derived from impedance cardiography are ventricular stroke column, cardiac output, cardiac index and Heather index. The program digitizes data collected from the Minnesota Impedance Cardiograph, Electrocardiography (ECG), and respiratory cycles and then stores these data on hard disk. It computes the cardiodynamic functions using interactive graphics and stores the means and standard deviations of each 15-sec data epoch on floppy disk. This software was designed on a Digital PRO380 microcomputer and used version 2.0 of P/OS, with (minimally) a 4-channel 16-bit analog/digital (A/D) converter. Applications software is written in FORTRAN 77, and uses Digital's Pro-Tool Kit Real Time Interface Library, CORE Graphic Library, and laboratory routines. Source code can be readily modified to accommodate alternative detection, A/D conversion and interactive graphics. The object code utilizing overlays and multitasking has a maximum of 50 Kbytes.
Wavelet transformation to determine impedance spectra of lithium-ion rechargeable battery
NASA Astrophysics Data System (ADS)
Hoshi, Yoshinao; Yakabe, Natsuki; Isobe, Koichiro; Saito, Toshiki; Shitanda, Isao; Itagaki, Masayuki
2016-05-01
A new analytical method is proposed to determine the electrochemical impedance of lithium-ion rechargeable batteries (LIRB) from time domain data by wavelet transformation (WT). The WT is a waveform analysis method that can transform data in the time domain to the frequency domain while retaining time information. In this transformation, the frequency domain data are obtained by the convolution integral of a mother wavelet and original time domain data. A complex Morlet mother wavelet (CMMW) is used to obtain the complex number data in the frequency domain. The CMMW is expressed by combining a Gaussian function and sinusoidal term. The theory to select a set of suitable conditions for variables and constants related to the CMMW, i.e., band, scale, and time parameters, is established by determining impedance spectra from wavelet coefficients using input voltage to the equivalent circuit and the output current. The impedance spectrum of LIRB determined by WT agrees well with that measured using a frequency response analyzer.
Buehring, B; Siglinsky, E; Krueger, D; Evans, W; Hellerstein, M; Yamada, Y; Binkley, N
2018-03-01
DXA-measured lean mass is often used to assess muscle mass but has limitations. Thus, we compared DXA lean mass with two novel methods-bioelectric impedance spectroscopy and creatine (methyl-d3) dilution. The examined methodologies did not measure lean mass similarly and the correlation with muscle biomarkers/function varied. Muscle function tests predict adverse health outcomes better than lean mass measurement. This may reflect limitations of current mass measurement methods. Newer approaches, e.g., bioelectric impedance spectroscopy (BIS) and creatine (methyl-d3) dilution (D3-C), may more accurately assess muscle mass. We hypothesized that BIS and D3-C measured muscle mass would better correlate with function and bone/muscle biomarkers than DXA measured lean mass. Evaluations of muscle/lean mass, function, and serum biomarkers were obtained in older community-dwelling adults. Mass was assessed by DXA, BIS, and orally administered D3-C. Grip strength, timed up and go, and jump power were examined. Potential muscle/bone serum biomarkers were measured. Mass measurements were compared with functional and serum data using regression analyses; differences between techniques were determined by paired t tests. Mean (SD) age of the 112 (89F/23M) participants was 80.6 (6.0) years. The lean/muscle mass assessments were correlated (.57-.88) but differed (p < 0.0001) from one another with DXA total body less head being highest at 37.8 (7.3) kg, D3-C muscle mass at 21.1 (4.6) kg, and BIS total body intracellular water at 17.4 (3.5) kg. All mass assessment methods correlated with grip strength and jump power (R = 0.35-0.63, p < 0.0002), but not with gait speed or repeat chair rise. Lean mass measures were unrelated to the serum biomarkers measured. These three methodologies do not similarly measure muscle/lean mass and should not be viewed as being equivalent. Functional tests assessing maximal muscle strength/power (grip strength and jump power) correlated with all mass measures whereas gait speed was not. None of the selected serum measures correlated with mass. Efforts to optimize muscle mass assessment and identify their relationships with health outcomes are needed.
Tissue characterization using electrical impedance spectroscopy data: a linear algebra approach.
Laufer, Shlomi; Solomon, Stephen B; Rubinsky, Boris
2012-06-01
In this study, we use a new linear algebra manipulation on electrical impedance spectroscopy measurements to provide real-time information regarding the nature of the tissue surrounding the needle in minimal invasive procedures. Using a Comsol Multiphysics three-dimensional model, a phantom based on ex vivo animal tissue and in vivo animal data, we demonstrate how tissue inhomogeneity can be characterized without any previous knowledge of the electrical properties of the different tissues, except that they should not be linearly dependent on a certain frequency range. This method may have applications in needle biopsies, radiation seeds, or minimally invasive surgery and can reduce the number of computer tomography or magnetic resonance imaging images. We conclude by demonstrating how this mathematical approach can be useful in other applications.
A unique chromatin complex occupies young α-satellite arrays of human centromeres
Henikoff, Jorja G.; Thakur, Jitendra; Kasinathan, Sivakanthan; Henikoff, Steven
2015-01-01
The intractability of homogeneous α-satellite arrays has impeded understanding of human centromeres. Artificial centromeres are produced from higher-order repeats (HORs) present at centromere edges, although the exact sequences and chromatin conformations of centromere cores remain unknown. We use high-resolution chromatin immunoprecipitation (ChIP) of centromere components followed by clustering of sequence data as an unbiased approach to identify functional centromere sequences. We find that specific dimeric α-satellite units shared by multiple individuals dominate functional human centromeres. We identify two recently homogenized α-satellite dimers that are occupied by precisely positioned CENP-A (cenH3) nucleosomes with two ~100–base pair (bp) DNA wraps in tandem separated by a CENP-B/CENP-C–containing linker, whereas pericentromeric HORs show diffuse positioning. Precise positioning is largely maintained, whereas abundance decreases exponentially with divergence, which suggests that young α-satellite dimers with paired ~100-bp particles mediate evolution of functional human centromeres. Our unbiased strategy for identifying functional centromeric sequences should be generally applicable to tandem repeat arrays that dominate the centromeres of most eukaryotes. PMID:25927077
Rutkove, Seward B; Geisbush, Tom R; Mijailovic, Aleksandar; Shklyar, Irina; Pasternak, Amy; Visyak, Nicole; Wu, Jim S; Zaidman, Craig; Darras, Basil T
2014-07-01
Electrical impedance myography and quantitative ultrasound are two noninvasive, painless, and effort-independent approaches for assessing neuromuscular disease. Both techniques have potential to serve as useful biomarkers in clinical trials in Duchenne muscular dystrophy. However, their comparative sensitivity to disease status and how they relate to one another are unknown. We performed a cross-sectional analysis of electrical impedance myography and quantitative ultrasound in 24 healthy boys and 24 with Duchenne muscular dystrophy, aged 2 to 14 years with trained research assistants performing all measurements. Three upper and three lower extremity muscles were studied unilaterally in each child, and the data averaged for each individual. Both electrical impedance myography and quantitative ultrasound differentiated healthy boys from those with Duchenne muscular dystrophy (P < 0.001 for both). Quantitative ultrasound values correlated with age in Duchenne muscular dystrophy boys (rho = 0.45; P = 0.029), whereas electrical impedance myography did not (rho = -0.31; P = 0.14). However, electrical impedance myography phase correlated with age in healthy boys (rho = 0.51; P = 0.012), whereas quantitative ultrasound did not (rho = -0.021; P = 0.92). In Duchenne muscular dystrophy boys, electrical impedance myography phase correlated with the North Star Ambulatory Assessment (rho = 0.65; P = 0.022); quantitative ultrasound revealed a near-significant association (rho = -0.56; P = 0.060). The two technologies trended toward a moderate correlation with one another in the Duchenne muscular dystrophy cohort but not in the healthy group (rho = -0.40; P = 0.054 and rho = -0.32; P = 0.13, respectively). Electrical impedance myography and quantitative ultrasound are complementary modalities for the assessment of boys with Duchenne muscular dystrophy; further study and application of these two modalities alone or in combination in a longitudinal fashion are warranted. Copyright © 2014 Elsevier Inc. All rights reserved.
Multi-channel electrical impedance tomography for regional tissue hydration monitoring.
Chen, Xiaohui; Kao, Tzu-Jen; Ashe, Jeffrey M; Boverman, Gregory; Sabatini, James E; Davenport, David M
2014-06-01
Poor assessment of hydration status during hemodialysis can lead to under- or over-hydration in patients with consequences of increased morbidity and mortality. In current practice, fluid management is largely based on clinical assessments to estimate dry weight (normal hydration body weight). However, hemodialysis patients usually have co-morbidities that can make the signs of fluid status ambiguous. Therefore, achieving normal hydration status remains a major challenge for hemodialysis therapy. Electrical impedance technology has emerged as a promising method for hydration monitoring due to its non-invasive nature, low cost and ease-of-use. Conventional electrical impedance-based hydration monitoring systems employ single-channel current excitation (either 2-electrode or 4-electrode methods) to perturb and extract averaged impedance from bulk tissue and use generalized models from large populations to derive hydration estimates. In the present study, a prototype, single-frequency electrical impedance tomography (EIT) system with simultaneous multi-channel current excitation was used to enable regional hydration change detection. We demonstrated the capability to detect a difference in daily impedance change between left leg and right leg in healthy human subjects, who wore a compression sock only on one leg to reduce daily gravitational fluid accumulation. The impedance difference corresponded well with the difference of lower leg volume change between left leg and right leg measured by volumetry, which on average is ~35 ml, accounting for 0.7% of the lower leg volume. We have demonstrated the feasibility of using multi-channel EIT to extract hydration information in different tissue layers with minimal skin interference. Our simultaneous, multi-channel current excitation approach provides an effective method to separate electrode contact impedance and skin condition artifacts from hydration signals. The prototype system has the potential to be used in clinical settings for helping optimize patient fluid management during hemodialysis as well as for home monitoring of patients with congestive heart failure, chronic kidney disease, diabetes and other diseases with peripheral edema symptoms.
Fused-data transrectal EIT for prostate cancer imaging.
Murphy, Ethan K; Wu, Xiaotian; Halter, Ryan J
2018-05-25
Prostate cancer is a significant problem affecting 1 in 7 men. Unfortunately, the diagnostic gold-standard of ultrasound-guided biopsy misses 10%-30% of all cancers. The objective of this study was to develop an electrical impedance tomography (EIT) approach that has the potential to image the entire prostate using multiple impedance measurements recorded between electrodes integrated onto an end-fired transrectal ultrasound (TRUS) device and a biopsy probe (BP). Simulations and sensitivity analyses were used to investigate the best combination of electrodes, and measured tank experiments were used to evaluate a fused-data transrectal EIT (fd-TREIT) and BP approach. Simulations and sensitivity analysis revealed that (1) TREIT measurements are not sufficiently sensitive to image the whole prostate, (2) the combination of TREIT + BP measurements increases the sensitive region of TREIT-only measurements by 12×, and (3) the fusion of multiple TREIT + BP measurements collected during a routine or customized 12-core biopsy procedure can cover up to 76.1% or 94.1% of a nominal 50 cm 3 prostate, respectively. Three measured tank experiments of the fd-TREIT + BP approach successfully and accurately recovered the positions of 2-3 metal or plastic inclusions. The measured tank experiments represent important steps in the development of an algorithm that can combine EIT from multiple locations and from multiple probes-data that could be collected during a routine TRUS-guided 12-core biopsy. Overall, this result is a step towards a clinically deployable impedance imaging approach to scanning the entire prostate, which could significantly help to improve prostate cancer diagnosis.
1990-09-01
FORMULATION OF PROBLEM denoted by AZ and is given by With reference to a cylindrical polar coordinate 17-Z-Zs.- P, 1." * ()d. (4a) system (p,O,Z) the...without limit as a approaches zero. This formulation is not actually valid in this limiting case since one terminal of the generator would then be connected...current. APPE.IXx I Formulation of the input impedance. An expression is here for- mulated for the input impedance at the terminals of an antenna
Gynecologic electrical impedance tomograph
NASA Astrophysics Data System (ADS)
Korjenevsky, A.; Cherepenin, V.; Trokhanova, O.; Tuykin, T.
2010-04-01
Electrical impedance tomography extends to the new and new areas of the medical diagnostics: lungs, breast, prostate, etc. The feedback from the doctors who use our breast EIT diagnostic system has induced us to develop the 3D electrical impedance imaging device for diagnostics of the cervix of the uterus - gynecologic impedance tomograph (GIT). The device uses the same measuring approach as the breast imaging system: 2D flat array of the electrodes arranged on the probe with handle is placed against the body. Each of the 32 electrodes of the array is connected in turn to the current source while the rest electrodes acquire the potentials on the surface. The current flows through the electrode of the array and returns through the remote electrode placed on the patient's limb. The voltages are measured relative to another remote electrode. The 3D backprojection along equipotential surfaces is used to reconstruct conductivity distribution up to approximately 1 cm in depth. Small number of electrodes enables us to implement real time imaging with a few frames per sec. rate. The device is under initial testing and evaluation of the imaging capabilities and suitability of usage.
Shkirskiy, Viacheslav; King, Andrew D; Gharbi, Oumaïma; Volovitch, Polina; Scully, John R; Ogle, Kevin; Birbilis, Nick
2015-02-23
The electrochemical impedance of reactive metals such as magnesium is often complicated by an obvious inductive loop with decreasing frequency of the AC polarising signal. The characterisation and ensuing explanation of this phenomenon has been lacking in the literature to date, being either ignored or speculated. Herein, we couple electrochemical impedance spectroscopy (EIS) with online atomic emission spectroelectrochemistry (AESEC) to simultaneously measure Mg-ion concentration and electrochemical impedance spectra during Mg corrosion, in real time. It is revealed that Mg dissolution occurs via Mg(2+) , and that corrosion is activated, as measured by AC frequencies less than approximately 1 Hz approaching DC conditions. The result of this is a higher rate of Mg(2+) dissolution, as the voltage excitation becomes slow enough to enable all Mg(2+) -enabling processes to adjust in real time. The manifestation of this in EIS data is an inductive loop. The rationalisation of such EIS behaviour, as it relates to Mg, is revealed for the first time by using concurrent AESEC. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Sound pressure gain produced by the human middle ear.
Kurokawa, H; Goode, R L
1995-10-01
The acoustic function of the middle ear is to match sound passing from the low impedance of air to the high impedance of cochlear fluid. Little information is available on the actual middle ear pressure gain in human beings. This article describes experiments on middle ear pressure gain in six fresh human temporal bones. Stapes footplate displacement and phase were measured with a laser Doppler vibrometer before and after removal of the tympanic membrane, malleus, and incus. Acoustic insulation of the round window with clay was performed. Umbo displacement was also measured before tympanic membrane removal to assess baseline tympanic membrane function. The middle ear has its major gain in the lower frequencies, with a peak near 0.9 kHz. The mean gain was 23.0 dB below 1.0 kHz, the resonant frequency of the middle ear; the mean peak gain was 26.6 dB. Above 1.0 kHz, the second pressure gain decreased at a rate of -8.6 dB/octave, with a mean gain of 6.5 dB at 4.0 kHz. Only a small amount of gain was present above 7.0 kHz. Significant individual differences in pressure gain were found between ears that appeared related to variations in tympanic membrane function and not to variations in cochlear impedance.
Flexible Molybdenum Electrodes towards Designing Affinity Based Protein Biosensors
Kamakoti, Vikramshankar; Panneer Selvam, Anjan; Radha Shanmugam, Nandhinee; Muthukumar, Sriram; Prasad, Shalini
2016-01-01
Molybdenum electrode based flexible biosensor on porous polyamide substrates has been fabricated and tested for its functionality as a protein affinity based biosensor. The biosensor performance was evaluated using a key cardiac biomarker; cardiac Troponin-I (cTnI). Molybdenum is a transition metal and demonstrates electrochemical behavior upon interaction with an electrolyte. We have leveraged this property of molybdenum for designing an affinity based biosensor using electrochemical impedance spectroscopy. We have evaluated the feasibility of detection of cTnI in phosphate-buffered saline (PBS) and human serum (HS) by measuring impedance changes over a frequency window from 100 mHz to 1 MHz. Increasing changes to the measured impedance was correlated to the increased dose of cTnI molecules binding to the cTnI antibody functionalized molybdenum surface. We achieved cTnI detection limit of 10 pg/mL in PBS and 1 ng/mL in HS medium. The use of flexible substrates for designing the biosensor demonstrates promise for integration with a large-scale batch manufacturing process. PMID:27438863
DOE Office of Scientific and Technical Information (OSTI.GOV)
Al-Odwani, A.; Al-Tabatabaei, M.; Carew, J.
1997-08-01
Electrochemical impedance spectroscopy (EIS) was used to evaluate the corrosion performance of four high chromium stainless steels and Grade 2 titanium in flowing Arabian Gulf natural seawater. The EIS provided information concerning the changes to the interfacial impedance as a function of exposure time for these alloys. The impedance spectra for all the alloys showed slight changes at the low frequency region over the exposure period. The open-circuit potentials (OCP) of these alloys were also monitored as a function of exposure time. The stainless steel alloys exhibited slight fluctuation in potential around the initial exposure potential. However, Grade 2 titaniummore » initial potential was more active and then gradually shifted towards the noble direction. The linear polarization resistance (LPR) method indicated that Grade 2 titanium exhibited the lowest corrosion rate with respect to the stainless steel alloys. The results of the EIS analysis and OCP indicated that Grade 2 titanium performed better than the four high chromium stainless steel alloys.« less
Qualitative human body composition analysis assessed with bioelectrical impedance.
Talluri, T
1998-12-01
Body composition is generally aiming at quantitative estimates of fat mass, inadequate to assess nutritional states that on the other hand are well defined by the intra/extra cellular masses proportion (ECM/BCM). Direct measures performed with phase sensitive bioelectrical impedance analyzers can be used to define the current distribution in normal and abnormal populations. Phase angle and reactance nomogram is directly reflecting the ECM/BCM pathways proportions and body impedance analysis (BIA) is also validated to estimate the individual content of body cell mass (BCM). A new body cell mass index (BCMI) obtained dividing the weight of BCM in kilograms by the body surface in square meters is confronted to the scatterplot distribution of phase angle and reactance values obtained from controls and patients, and proposed as a qualitative approach to identify abnormal ECM/BCM ratios and nutritional states.
Vibration analysis of rotor systems using reduced subsystem models
NASA Technical Reports Server (NTRS)
Fan, Uei-Jiun; Noah, Sherif T.
1989-01-01
A general impedance method using reduced submodels has been developed for the linear dynamic analysis of rotor systems. Formulated in terms of either modal or physical coordinates of the subsystems, the method enables imbalance responses at specific locations of the rotor systems to be efficiently determined from a small number of 'master' degrees of freedom. To demonstrate the capability of this impedance approach, the Space Shuttle Main Engine high-pressure oxygen turbopump has been investigated to determine the bearing loads due to imbalance. Based on the same formulation, an eigenvalue analysis has been performed to study the system stability. A small 5-DOF model has been utilized to illustrate the application of the method to eigenvalue analysis. Because of its inherent characteristics of allowing formulation of reduced submodels, the impedance method can significantly increase the computational speed.
Characterization of DUT impedance in immunity test setups
NASA Astrophysics Data System (ADS)
Hassanpour Razavi, Seyyed Ali; Frei, Stephan
2016-09-01
Several immunity test procedures for narrowband radiated electromagnetic energy are available for automotive components. The ISO 11452 series describes the most commonly used test methods. The absorber line shielded enclosure (ALSE) is often considered as the most reliable method. However, testing with the bulk current injection (BCI) can be done with less efforts and is often preferred. As the test setup in both procedures is quite similar, there were several trials for finding appropriate modifications to the BCI in order to increase the matching to the ALSE. However, the lack of knowledge regarding the impedance of the tested component, makes it impossible to find the equivalent current to be injected by the BCI and a good match cannot be achieved. In this paper, three approaches are proposed to estimate the termination impedance indirectly by using different current probes.
Relations Between Aortic Stiffness and Left Ventricular Mechanical Function in the Community.
Bell, Vanessa; McCabe, Elizabeth L; Larson, Martin G; Rong, Jian; Merz, Allison A; Osypiuk, Ewa; Lehman, Birgitta T; Stantchev, Plamen; Aragam, Jayashri; Benjamin, Emelia J; Hamburg, Naomi M; Vasan, Ramachandran S; Mitchell, Gary F; Cheng, Susan
2017-01-09
Aortic stiffness impairs optimal ventricular-vascular coupling and left ventricular systolic function, particularly in the long axis. Left ventricular global longitudinal strain (GLS) has recently emerged as a sensitive measure of early cardiac dysfunction. In this study, we investigated the relation between aortic stiffness and GLS in a large community-based sample. In 2495 participants (age 39-90 years, 57% women) of the Framingham Offspring and Omni cohorts, free of cardiovascular disease, we performed tonometry to measure arterial hemodynamics and echocardiography to assess cardiac function. Aortic stiffness was evaluated as carotid-femoral pulse wave velocity and as characteristic impedance, and GLS was calculated using speckle tracking-based measurements. In multivariable analyses adjusting for age, sex, height, systolic blood pressure, augmentation index, left ventricular structure, and additional cardiovascular risk factors, increased carotid-femoral pulse wave velocity (B±SE: 0.122±0.030% strain per SD, P<0.0001) and characteristic impedance (0.090±0.029, P=0.002) were both associated with worse GLS. We observed effect modification by sex on the relation between characteristic impedance and GLS (P=0.004); in sex-stratified multivariable analyses, the relation between greater characteristic impedance and worse GLS persisted in women (0.145±0.039, P=0.0003) but not in men (P=0.73). Multiple measures of increased aortic stiffness were cross-sectionally associated with worse GLS after adjusting for hemodynamic variables. Parallel reductions in left ventricular long axis shortening and proximal aortic longitudinal strain in individuals with a stiffened proximal aorta, from direct mechanical ventricular-vascular coupling, offers an alternative explanation for the observed relations. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
NASA Astrophysics Data System (ADS)
Berdnik, S. L.; Katrich, V. A.; Nesterenko, M. V.; Penkin, Yu. M.
2016-09-01
Purpose: A problem of electromagnetic wave diffraction by a longitudinal slot cut in a waveguide wide wall is solved. The slot is cut in a wide wall of a rectangular waveguide and radiates in a half-space above a perfectly conducting plane where two vertical impedance monopoles with arbitrary lengths placed with their bases placed on the plane. The paper is aimed at studying the electrodynamic characteristics of vibratorwaveguide-slot structures which allow to form the emission fields as that in a Clavin element with two identical passive ideally conducting monopoles of a fixed length located on a set distance from a slot center on both sides of a narrow halfwave slot. Design/methodology/approach: The problem is solved by a generalized method of induced electromotive and magnetomotive forces in approximation of electric currents in the vibrators and equivalent magnetic current in the slot by the functions obtained by the asymptotic averaging method. Findings: The influence of geometric parameters of the structure on the directional characteristics of Clavin type element is analyzed on the assumption of simultaneous account for relative level of sidelobes in the E-plane and beamwidth differences at -3 dB level in the main planes. It is shown that the directional characteristics and energy characteristics of the radiators: radiation and reflection coefficients, antenna directivity and gain can be varied within wide limits by changing the electrical length and/or distributed surface impedances of the vibrators, providing at that a low level of radiation within a slot plane. Conclusions: The results obtained can be useful when designing both small-size and multi-element antenna arrays with Clavin elements.
Single Cell "Glucose Nanosensor" Verifies Elevated Glucose Levels in Individual Cancer Cells.
Nascimento, Raphael A S; Özel, Rıfat Emrah; Mak, Wai Han; Mulato, Marcelo; Singaram, Bakthan; Pourmand, Nader
2016-02-10
Because the transition from oxidative phosphorylation to anaerobic glycolytic metabolism is a hallmark of cancer progression, approaches to identify single living cancer cells by their unique glucose metabolic signature would be useful. Here, we present nanopipettes specifically developed to measure glucose levels in single cells with temporal and spatial resolution, and we use this technology to verify the hypothesis that individual cancer cells can indeed display higher intracellular glucose levels. The nanopipettes were functionalized as glucose nanosensors by immobilizing glucose oxidase (GOx) covalently to the tip so that the interaction of glucose with GOx resulted in a catalytic oxidation of β-d-glucose to d-gluconic acid, which was measured as a change in impedance due to drop in pH of the medium at the nanopipette tip. Calibration studies showed a direct relationship between impedance changes at the tip and glucose concentration in solution. The glucose nanosensor quantified single cell intracellular glucose levels in human fibroblasts and the metastatic breast cancer lines MDA-MB-231 and MCF7 and revealed that the cancer cells expressed reproducible and reliable increases in glucose levels compared to the nonmalignant cells. Nanopipettes allow repeated sampling of the same cell, as cells remain viable during and after measurements. Therefore, nanopipette-based glucose sensors provide an approach to compare changes in glucose levels with changes in proliferative or metastatic state. The platform has great promise for mechanistic investigations, as a diagnostic tool to distinguish cancer cells from nonmalignant cells in heterogeneous tissue biopsies, as well as a tool for monitoring cancer progression in situ.
NASA Astrophysics Data System (ADS)
Gupta, Surbhi; Deshpande, S. K.; Sathe, V. G.; Siruguri, V.
2018-04-01
We present dielectric, complex impedance, modulus spectroscopy and AC conductivity studies of the compound BaFe10Sc2O19 as a function of temperature and frequency to understand the conduction mechanism. The variation in complex dielectric constant with frequency and temperature were analyzed on the basis of Maxwell-Wagner-Koop's theory and charge hopping between ferrous and ferric ions. The complex impedance spectroscopy study shows only grain contribution whereas complex modulus plot shows two semicircular arcs which indicate both grain and grain boundary contributions in conduction mechanism. AC conductivity has also been evaluated which follows the Jonscher's law. The activation energy calculated from temperature dependence of DC conductivity comes out to be Ea˜ 0.31eV.
NASA Astrophysics Data System (ADS)
Taylor, Maurice C.; Trumpower, David L.; Purse, Edward R.
2015-12-01
Workplaces are settings where power, knowledge and self are brought together in a complex social environment which includes various forms of struggle related to identity, agency, socio-cultural norms, political structures and functional practices. The purpose of this article is to uncover how formal and informal work-related learning processes influence the identity transformation of workers with low literacy and essential skills. Drawing on two recent Canadian data bases which serve as cases in this study, the position taken by the authors is that the organisational context can both facilitate and impede worker subjectivity. Various conditions, approaches to learning and training pathways are examined as they contribute to social cognitive and transformative learning theories.
NASA Astrophysics Data System (ADS)
Gibson, S. W.
This book is concerned with providing an explanation of the function of an antenna without delving too deeply into the mathematics or theory. The characteristics of an antenna are examined, taking into account aspects of antenna radiation, wave motion on the antenna, resistance in the antenna, impedance, the resonant antenna, the effect of the ground, polarization, radiation patterns, coupling effects between antenna elements, and receiving vs. transmitting. Aspects of propagation are considered along with the types of antennas, transmission lines, matching devices, questions of antenna design, antennas for the lower frequency bands, antennas for more than one band, limited space antennas, VHF antennas, and antennas for 20, 15, and 10 meters. Attention is given to devices for measuring antenna parameters, approaches for evaluating the antenna, questions of safety, and legal aspects.
A behavior-analytic view of psychological health
Follette, William C.; Bach, Patricia A.; Follette, Victoria M.
1993-01-01
This paper argues that a behavioral analysis of psychological health is useful and appropriate. Such an analysis will allow us to better evaluate intervention outcomes without resorting only to the assessment of pathological behavior, thus providing an alternative to the Diagnostic and Statistical Manual system of conceptualizing behavior. The goals of such an analysis are to distinguish between people and outcomes using each term of the three-term contingency as a dimension to consider. A brief review of other efforts to define psychological health is provided. Laboratory approaches to a behavioral analysis of healthy behavior are presented along with shortcomings in our science that impede our analysis. Finally, we present some of the functional characteristics of psychological health that we value. PMID:22478160
Hauschild, Daniela Barbieri; Barbosa, Eliana; Moreira, Emilia Addison Machado; Ludwig Neto, Norberto; Platt, Vanessa Borges; Piacentini Filho, Eduardo; Wazlawik, Elisabeth; Moreno, Yara Maria Franco
2016-06-01
(1) To compare nutrition and hydration status between a group of children/adolescents with cystic fibrosis (CFG; n = 46; median age, 8.5 years) and a control group without cystic fibrosis (CG). (2) To examine the association of nutrition and hydration status with lung function in the CFG. A cross-sectional study. Nutrition screening, anthropometric parameters, and bioelectrical impedance analysis (BIA) were assessed. The z scores for body mass index for age, height for age, mid upper arm circumference, triceps and subscapular skinfold thickness, mid upper arm muscle area, resistance/height, and reactance/height were calculated. Bioelectrical impedance vector analysis was conducted. Forced expiratory volume in 1 second <80% was considered lung function impairment. An adjusted logistic regression was applied (P < .05). In the CFG, lung function impairment was observed in 51.1%. All anthropometric parameters were lower, and the mean z-resistance/height and z-reactance/height were higher in the CFG (P < .05) compared with the CG. In the CFG, 43% were severely/mildly dehydrated, while none were in the CG (P = .007). In the CFG, there was an association between high nutrition risk-via nutrition screening (odds ratio [OR], 22.28; P < .05), lower values of anthropometric parameters, higher z-resistance/height (OR, 2.23; P < .05) and z-reactance/height (OR, 1.81; P < .05), and dehydration (OR, 4.94; P < .05)-and lung function impairment. The CFG exhibited a compromised nutrition status assessed by anthropometric and BIA parameters. Nutrition screening, anthropometric and BIA parameters, and hydration status were associated with lung function. © 2016 American Society for Parenteral and Enteral Nutrition.
NASA Astrophysics Data System (ADS)
Levin, V. L.; Servali, A.; Dunham, B.; Klaser, M.
2015-12-01
A 1200 km long array of seismic observatories from James Bay to the Atlantic coast covers nearly 2 Ga in time, from the Archean Superior Province to the Paleozoic Appalachian Orogen. We use traditional (P-to-SV) receiver function analysis for detailed characterization of the lithospheric mantle along the array, focusing on the 5-15 s delay range where direct conversions from within the lithosphere and crustal multiples are expected.Superior craton sites show exceptionaly clear receiver functions dominated by the first crustal multiple. Also, a negative phase consistent with impedance decrease at the Mid-Lithospheric Discontinuity (~8 s delay) is observed north of 51°N, within the La Grande and Opinaca terranes of the Superior province. In the Opatica terrane further south we see a positive phase at similar delays instead. This implies a downward impedance increase 70-80 km deep within the lithosphere, consistent with the Hales discontinuity. In the Abitibi terrane just north of the Grenville Front we see evidence for two impedance drops in the 60-130 km depth range. Within the Proterozoic Grenvile province receiver functions vary with direction at individual sites, and lack regional consistency. Crustal multiples are noticeably weaker. South of 49°N we once again find negative phases in the 8-10 s delay range. While weak and directionally-dependent in the central Grenville province, these phases are clear near the Appalachian Front (AF), and are followed by positive phases, suggesting thin low-velocity layers in the lower part of the lithosphere. Similarity of receiver function signatures on opposite sides of the AF suggests continuity of the lithosphere beneath it.South of the AF and north of the Norumbega Fault Zone (NFZ) in Maine we find positive phases at ~10 s delays. The implied increase in impedance at ~75 km depth is puzzling. We also find previously-reported weak negative phases in the 6-8 s delay range. South of the NFZ a strong negative phase at ~9 s delay likely marks the bottom of the lithosphere.
[Functional methods of the esophagus examination].
Valitova, E R; Bordin, D S; Ianova, O B; Vasnev, O S; Masharova, A A
2010-01-01
Manometry of the esophagus is the "gold standard" in diagnosing diseases of the esophagus associated with motor disorders. The combination of manometry with impedance gives an indication of violation of bolus transport along the esophagus. High resolution manometry is new method that provides the most accurate information about the functional anatomy of the esophagus and its sphincters, as well as accurately characterizes the esophageal-gastric junction. We can increase the diagnostic value of daily pH-monitoring by analyzing communication with reflux symptoms. The combination of pH and impedance can identify different types of reflux (acid, sour, gas, liquid and mixed) in patients with symptoms of GERD and related Ahil, after gastric resection in children and infants, to evaluate the effectiveness of antireflux therapy.
Futschik, K; Ammann, M; Bachmayer, S; Kenndler, E
1993-08-06
The ionic species that are formed during the microbial growth of Escherichia coli were determined by capillary isotachophoresis as a function of the time of cultivation. This formation was indicated by the change in a sum parameter, the impedance of the nutrient broth, measured by a special electrode system. Based on the determination of the individual ions formed under the given conditions (identified as acetate, lactate, alpha-ketoglutarate, fumarate, ammonium and probably a simple amine), the change in conductivity was calculated and compared with that obtained by the impedance measurement of the bulk medium. From the results it can be concluded that the change in the sum parameter as a function of time is originated by the ions determined.
Pressure-Flow Analysis for the Assessment of Pediatric Oropharyngeal Dysphagia.
Ferris, Lara; Rommel, Nathalie; Doeltgen, Sebastian; Scholten, Ingrid; Kritas, Stamatiki; Abu-Assi, Rammy; McCall, Lisa; Seiboth, Grace; Lowe, Katie; Moore, David; Faulks, Jenny; Omari, Taher
2016-10-01
To determine which objective pressure-impedance measures of pharyngeal swallowing function correlated with clinically assessed severity of oropharyngeal dysphagia (OPD) symptoms. Forty-five children with OPD and 34 control children without OPD were recruited and up to 5 liquid bolus swallows were recorded with a solid-state high-resolution manometry with impedance catheter. Individual measures of pharyngeal and upper esophageal sphincter (UES) function and a swallow risk index composite score were derived for each swallow, and averaged data for patients with OPD were compared with those of control children without OPD. Clinical severity of OPD symptoms and oral feeding competency was based on the validated Dysphagia Disorders Survey and Functional Oral Intake Scale. Those objective measures that were markers of UES relaxation, UES opening, and pharyngeal flow resistance differentiated patients with and without OPD symptoms. Patients demonstrating abnormally high pharyngeal intrabolus pressures and high UES resistance, markers of outflow obstruction, were most likely to have signs and symptoms of overt Dysphagia Disorders Survey (OR 9.24, P = .05, and 9.7, P = .016, respectively). Pharyngeal motor patterns can be recorded in children by the use of HRIM and pharyngeal function can be defined objectively with the use of pressure-impedance measures. Objective measurements suggest that pharyngeal dysfunction is common in children with clinical signs of OPD. A key finding of this study was evidence of markers of restricted UES opening. Copyright © 2016 Elsevier Inc. All rights reserved.
Air swallowing, belching, acid and non-acid reflux in patients with functional dyspepsia.
Conchillo, J M; Selimah, M; Bredenoord, A J; Samsom, M; Smout, A J P M
2007-04-15
Frequent belching is a common symptom in patients with functional dyspepsia with a reported incidence up to 80%. We hypothesized that patients with functional dyspepsia possibly have a higher frequency of belching than healthy subjects secondary to frequent air swallowing. To assess air swallowing, belching, acid and non-acid reflux patterns of patients with functional dyspepsia. Combined 24-h oesophageal impedance and pH monitoring was performed in 10 functional dyspepsia patients and 10 controls. Analysis of the impedance-pH signals included incidence of air swallows, belching, acid and non-acid reflux. The incidence of air swallows in functional dyspepsia patients were significantly higher compared with controls (153 +/- 15 vs. 79 +/- 10, P < 0.001), while the incidence of liquid-only swallows were not significantly increased. The proportions of gas-containing reflux episodes (belches) and non-acid reflux episodes in functional dyspepsia patients were significantly higher when compared with controls (66.4 vs. 44.4%, P = 0.04 and 70.1 vs. 45.9%, P = 0.009, respectively). Patients with functional dyspepsia swallow air more frequently than controls and this is associated with an increased incidence of non-acid gaseous gastro-oesophageal reflux.
A revolutionary concept to improve the efficiency of IC antennas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Milanesio, D.; Maggiora, R.
2014-02-12
The successful design of an Ion Cyclotron (IC) antenna mainly relies on the capability of coupling high power to the plasma (MW), feature that is currently reached by allowing rather high voltages (tens of kV) on the unavoidable unmatched part of the feeding lines. This requirement is often responsible of arcs along the transmission lines and other unwanted phenomena that considerably limit the usage of IC launchers. In this work, we suggest and describe a revolutionary approach based on high impedance surfaces, which allows to increase the antenna radiation efficiency and, hence, to highly reduce the imposed voltages to couplemore » the same level of power to the plasma. High-impedance surfaces are periodic metallic structures (patches) displaced usually on top of a dielectric substrate and grounded by means of vertical posts usually embedded inside a dielectric, in a mushroom-like shape. In terms of working properties, high impedance surfaces are electrically thin in-phase reflectors, i.e. they present a high impedance, within a given frequency band, such that the image currents are in-phase with the currents of the antenna itself, thus determining a significant efficiency increase. While the usual design of a high impedance surface requires the presence of a dielectric layer, some alternative solutions can be realized in vacuum, taking advantage of double layers ofmetallic patches. After an introductory part on the properties of high impedance surfaces, this work documents both their design by means of numerical codes and their implementation on a scaled mock-up.« less
A revolutionary concept to improve the efficiency of ion cyclotron antennas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Milanesio, D., E-mail: daniele.milanesio@polito.it; Maggiora, R., E-mail: riccardo.maggiora@polito.it
2014-06-15
The successful design of an ion cyclotron (IC) antenna mainly relies on the capability of coupling high power to the plasma (MW), feature that is currently reached by allowing rather high voltages (tens of kV) on the unavoidable unmatched part of the feeding lines. This requirement is often responsible of arcs along the transmission lines and other unwanted phenomena, such as rectification discharges or hotspots, that considerably limit the usage of IC launchers. In this work, we suggest and describe a revolutionary approach based on high impedance surfaces, which allows to increase the antenna radiation efficiency and, hence, to highlymore » reduce the imposed voltages to couple the same level of power to the plasma. High-impedance surfaces are periodic metallic structures (patches) displaced usually on top of a dielectric substrate and grounded by means of vertical posts usually embedded inside a dielectric, in a mushroom-like shape. In terms of working properties, high impedance surfaces are electrically thin in-phase reflectors, i.e., they present a high impedance, within a given frequency band, such that the image currents are in-phase with the currents of the antenna itself, thus determining a significant efficiency increase. While the usual design of a high impedance surface requires the presence of a dielectric layer, some alternative solutions can be realised in vacuum, taking advantage of double layers of metallic patches. After an introductory part on the properties of high impedance surfaces, this work documents both their design by means of numerical codes and their implementation on a scaled mock-up.« less
Impedance testing on cochlear implants after electroconvulsive therapy.
McRackan, Theodore R; Rivas, Alejandro; Hedley-Williams, Andrea; Raj, Vidya; Dietrich, Mary S; Clark, Nathaniel K; Labadie, Robert F
2014-12-01
Cochlear implants (CI) are neural prostheses that restore hearing to individuals with profound sensorineural hearing loss. The surgically implanted component consists of an electrode array, which is threaded into the cochlea, and an electronic processor, which is buried under the skin behind the ear. The Food and Drug Administration and CI manufacturers contend that electroconvulsive therapy (ECT) is contraindicated in CI recipients owing to risk of damage to the implant and/or the patient. We hypothesized that ECT does no electrical damage to CIs. Ten functional CIs were implanted in 5 fresh cadaveric human heads. Each head then received a consecutive series of 12 unilateral ECT sessions applying maximum full pulse-width energy settings. Electroconvulsive therapy was delivered contralaterally to 5 CIs and ipsilaterally to 5 CIs. Electrical integrity testing (impedance testing) of the electrode array was performed before and after CI insertion, and after the first, third, fifth, seventh, ninth, and 12th ECT sessions. Electroconvulsive therapy was performed by a staff psychiatrist experienced with the technique. Explanted CIs were sent back to the manufacturer for further integrity testing. No electrical damage was identified during impedance testing. Overall, there were statistically significant decreases in impedances (consistent with no electrical damage) when comparing pre-ECT impedance values to those after 12 sessions. There was no statistically significant difference (P > 0.05) in impedance values comparing ipsilateral to contralateral ECT. Manufacturer testing revealed no other electrical damage to the CIs. Electroconvulsive therapy does not seem to cause any detectable electrical injury to CIs.
NASA Astrophysics Data System (ADS)
Ecker, Madeleine; Gerschler, Jochen B.; Vogel, Jan; Käbitz, Stefan; Hust, Friedrich; Dechent, Philipp; Sauer, Dirk Uwe
2012-10-01
Battery lifetime prognosis is a key requirement for successful market introduction of electric and hybrid vehicles. This work aims at the development of a lifetime prediction approach based on an aging model for lithium-ion batteries. A multivariable analysis of a detailed series of accelerated lifetime experiments representing typical operating conditions in hybrid electric vehicle is presented. The impact of temperature and state of charge on impedance rise and capacity loss is quantified. The investigations are based on a high-power NMC/graphite lithium-ion battery with good cycle lifetime. The resulting mathematical functions are physically motivated by the occurring aging effects and are used for the parameterization of a semi-empirical aging model. An impedance-based electric-thermal model is coupled to the aging model to simulate the dynamic interaction between aging of the battery and the thermal as well as electric behavior. Based on these models different drive cycles and management strategies can be analyzed with regard to their impact on lifetime. It is an important tool for vehicle designers and for the implementation of business models. A key contribution of the paper is the parameterization of the aging model by experimental data, while aging simulation in the literature usually lacks a robust empirical foundation.
Packham, B; Barnes, G; Dos Santos, G Sato; Aristovich, K; Gilad, O; Ghosh, A; Oh, T; Holder, D
2016-06-01
Electrical impedance tomography (EIT) allows for the reconstruction of internal conductivity from surface measurements. A change in conductivity occurs as ion channels open during neural activity, making EIT a potential tool for functional brain imaging. EIT images can have >10 000 voxels, which means statistical analysis of such images presents a substantial multiple testing problem. One way to optimally correct for these issues and still maintain the flexibility of complicated experimental designs is to use random field theory. This parametric method estimates the distribution of peaks one would expect by chance in a smooth random field of a given size. Random field theory has been used in several other neuroimaging techniques but never validated for EIT images of fast neural activity, such validation can be achieved using non-parametric techniques. Both parametric and non-parametric techniques were used to analyze a set of 22 images collected from 8 rats. Significant group activations were detected using both techniques (corrected p < 0.05). Both parametric and non-parametric analyses yielded similar results, although the latter was less conservative. These results demonstrate the first statistical analysis of such an image set and indicate that such an analysis is an approach for EIT images of neural activity.
Hu, Gang; He, Bin
2011-01-01
Magnetoacoustic tomography with magnetic induction (MAT-MI) is an emerging approach for noninvasively imaging electrical impedance properties of biological tissues. The MAT-MI imaging system measures ultrasound waves generated by the Lorentz force, having been induced by magnetic stimulation, which is related to the electrical conductivity distribution in tissue samples. MAT-MI promises to provide fine spatial resolution for biological tissue imaging as compared to ultrasound resolution. In the present study, we first estimated the imaging spatial resolution by calculating the full width at half maximum (FWHM) of the system point spread function (PSF). The actual spatial resolution of our MAT-MI system was experimentally determined to be 1.51 mm by a parallel-line-source phantom with Rayleigh criterion. Reconstructed images made from tissue-mimicking gel phantoms, as well as animal tissue samples, were consistent with the morphological structures of the samples. The electrical conductivity value of the samples was determined directly by a calibrated four-electrode system. It has been demonstrated that MAT-MI is able to image the electrical impedance properties of biological tissues with better than 2 mm spatial resolution. These results suggest the potential of MAT-MI for application to early detection of small-size diseased tissues (e.g. small breast cancer). PMID:21858111
NASA Astrophysics Data System (ADS)
Huang, Yun-Tzu; Chang, Chia-Yu; Chen, Wei; Su, Chien-Hao; Hsu, Guo-Cheng; Chang, Chia-Ching
HER2 (human epidermal growth factor receptor 2) is one of the significant surface antigens of breast cancer Trace amount of HER2 protein in human serum is highly correlated to the tumor progression in breast cancers especially in the cases of recurrence. Therefore, HER2 detection of human serum is significant for early detection of cancer recurrence. Conventional HER2 detection approaches may not be sensitive enough or contain highly false positive rate or time consuming for accurate detection. Therefore, a rapid, highly sensitive and specific sensing is highly desired. By using HER2 specific binding peptide functionalized palladium thin film electrochemical electrode the HER2 protein concentration can be determined at sub-nanogram level by electrochemical impedance spectroscopy (EIS) within 10 mins. The Pd nano-film is sputtered on the flexible plastics substrate and reduces the cost of this electrode. Due to the low cost of the electrode, it is designed as a disposable biosensing probe which may reduce the concern of human sample contamination. The self-management after breast cancer operation may be feasible in the near future. Keywords: Electrochemical impedance spectroscopy(EIS), breast cancer, biosensor Corresponding author: ccchang01@faculty.nctu.edu.tw; Cheeshin Technology Co. Collaboration.
Packham, B; Barnes, G; dos Santos, G Sato; Aristovich, K; Gilad, O; Ghosh, A; Oh, T; Holder, D
2016-01-01
Abstract Electrical impedance tomography (EIT) allows for the reconstruction of internal conductivity from surface measurements. A change in conductivity occurs as ion channels open during neural activity, making EIT a potential tool for functional brain imaging. EIT images can have >10 000 voxels, which means statistical analysis of such images presents a substantial multiple testing problem. One way to optimally correct for these issues and still maintain the flexibility of complicated experimental designs is to use random field theory. This parametric method estimates the distribution of peaks one would expect by chance in a smooth random field of a given size. Random field theory has been used in several other neuroimaging techniques but never validated for EIT images of fast neural activity, such validation can be achieved using non-parametric techniques. Both parametric and non-parametric techniques were used to analyze a set of 22 images collected from 8 rats. Significant group activations were detected using both techniques (corrected p < 0.05). Both parametric and non-parametric analyses yielded similar results, although the latter was less conservative. These results demonstrate the first statistical analysis of such an image set and indicate that such an analysis is an approach for EIT images of neural activity. PMID:27203477
Impedance based time-domain modeling of lithium-ion batteries: Part I
NASA Astrophysics Data System (ADS)
Gantenbein, Sophia; Weiss, Michael; Ivers-Tiffée, Ellen
2018-03-01
This paper presents a novel lithium-ion cell model, which simulates the current voltage characteristic as a function of state of charge (0%-100%) and temperature (0-30 °C). It predicts the cell voltage at each operating point by calculating the total overvoltage from the individual contributions of (i) the ohmic loss η0, (ii) the charge transfer loss of the cathode ηCT,C, (iii) the charge transfer loss and the solid electrolyte interface loss of the anode ηSEI/CT,A, and (iv) the solid state and electrolyte diffusion loss ηDiff,A/C/E. This approach is based on a physically meaningful equivalent circuit model, which is parametrized by electrochemical impedance spectroscopy and time domain measurements, covering a wide frequency range from MHz to μHz. The model is exemplarily parametrized to a commercial, high-power 350 mAh graphite/LiNiCoAlO2-LiCoO2 pouch cell and validated by continuous discharge and charge curves at varying temperature. For the first time, the physical background of the model allows the operator to draw conclusions about the performance-limiting factor at various operating conditions. Not only can the model help to choose application-optimized cell characteristics, but it can also support the battery management system when taking corrective actions during operation.
Respiratory system dynamical mechanical properties: modeling in time and frequency domain.
Carvalho, Alysson Roncally; Zin, Walter Araujo
2011-06-01
The mechanical properties of the respiratory system are important determinants of its function and can be severely compromised in disease. The assessment of respiratory system mechanical properties is thus essential in the management of some disorders as well as in the evaluation of respiratory system adaptations in response to an acute or chronic process. Most often, lungs and chest wall are treated as a linear dynamic system that can be expressed with differential equations, allowing determination of the system's parameters, which will reflect the mechanical properties. However, different models that encompass nonlinear characteristics and also multicompartments have been used in several approaches and most specifically in mechanically ventilated patients with acute lung injury. Additionally, the input impedance over a range of frequencies can be assessed with a convenient excitation method allowing the identification of the mechanical characteristics of the central and peripheral airways as well as lung periphery impedance. With the evolution of computational power, the airway pressure and flow can be recorded and stored for hours, and hence continuous monitoring of the respiratory system mechanical properties is already available in some mechanical ventilators. This review aims to describe some of the most frequently used models for the assessment of the respiratory system mechanical properties in both time and frequency domain.
Tran, Damien; Ciret, Pierre; Ciutat, Aurélie; Durrieu, Gilles; Massabuau, Jean-Charles
2003-04-01
Bivalve closure responses to detect contaminants have often been studied in ecotoxicology as an aquatic pollution biosensor. We present a new laboratory procedure to estimate its potential and limits for various contaminants and animal susceptible to stress. The study was performed in the Asiatic clam Corbicula fluminea and applied to cadmium. To take into account the rate of spontaneous closures, we integrated stress problems associated with fixation by a valve in common apparatus and the spontaneous rhythm associated with circadian activity to focus on conditions with the lowest probability of spontaneous closing. Moreover, we developed an original system by impedance valvometry, using light-weight impedance electrodes, to study free-ranging animals in low-stress conditions and a new analytical approach to describe valve closure behavior as a function of response time and concentration of contaminant. In C. fluminea, we show that cadmium concentrations above 50 microg/L can be detected within less than 1 h, concentrations down to 16 microg/L require 5 h of integration time, and values lower than 16 microg/L cannot be distinguished from background noise. Our procedure improved by a factor of six the cadmium sensitivity threshold reported in the literature. Problems of field applications are discussed.
Compromised careers: the occupational transition of immigration and resettlement.
Suto, Melinda
2009-01-01
Work is a significant occupational transition that occurs with immigration and resettlement. Problems finding work and regaining economic capital are multi-factorial, differentiated by gender and mediated by specific contexts. Surprisingly, past education and work experience are unreliable predictors of successful employment outcomes. Critical theory and ethnographic concepts informed the methodological approach. Data were generated primarily through in-depth interviews, conducted in English, with 14 well-educated women who immigrated to Canada as adults and sought employment in their professions. The thematic findings were analyzed using Bourdieu's [7] concepts of capital, field and habitus. The theme Compromised Careers describes the downward occupational (work) mobility that occurs despite expectations that education, credentials and work experience are transferable to desirable employment. A devaluation of foreign qualifications and no relevant Canadian work experience function with gendered responsibilities, less social support, and time spent in resettlement activities to create negative work trajectories. The role that federal policies and professional organizations play is examined to reveal the tension between individuals' efforts to find employment and institutional barriers that impede these actions. A critical inquiry approach examined the ruling relations to show how power and privilege function in relation to migrants' occupational transitions.
Eddy-current inversion in the thin-skin limit: Determination of depth and opening for a long crack
NASA Astrophysics Data System (ADS)
Burke, S. K.
1994-09-01
A method for crack size determination using eddy-current nondestructive evaluation is presented for the case of a plate containing an infinitely long crack of uniform depth and uniform crack opening. The approach is based on the approximate solution to Maxwell's equations for nonmagnetic conductors in the limit of small skin depth and relies on least-squares polynomial fits to a normalized coil impedance function as a function of skin depth. The method is straightforward to implement and is relatively insensitive to both systematic and random errors. The procedure requires the computation of two functions: a normalizing function, which depends both on the coil parameters and the skin depth, and a crack-depth function which depends only on the coil parameters in addition to the crack depth. The practical perfomance of the method was tested using a set of simulated cracks in the form of electro-discharge machined slots in aluminum alloy plates. The crack depths and crack opening deduced from the eddy-current measurements agree with the actual crack dimensions to within 10% or better. Recommendations concerning the optimum conditions for crack sizing are also made.
Validation of a New Procedure for Impedance Eduction in Flow
NASA Technical Reports Server (NTRS)
Watson, W. R.; Jones, M. G.
2010-01-01
A new impedance eduction procedure is validated by comparing the educed impedance spectrum to that of an older but well-tested eduction procedure. The older procedure requires the installation of a microphone array in the liner test section but the new procedure removes this requirement. A 12.7-mm stainless steel plate and a conventional liner consisting of a perforated plate bonded to a honeycomb core are tested. Test data is acquired from a grazing flow, impedance tube facility for a range of source frequencies and mean flow Mach numbers for which only plane waves are cut on. For the stainless steel plate, the educed admittance spectrum using the new procedure shows an improvement over that of the old procedure. This improvement shows up primarily in the educed conductance spectrum. Both eduction procedures show discrepancies in educed admittance in the mid-frequency range. Indications are that this discrepancy is triggered by an inconsistency between the measured eduction data (that contains boundary layer effects) and the two eduction models (for which the boundary layer is neglected). For the conventional liner, both eduction procedures are in very good agreement with each other. Small discrepancies occur for one or two frequencies in the mid-frequency range and for frequencies beyond the cut on frequency of higher-order duct modes. This discrepancy in the midfrequency range occurs because an automated optimizer is used to educe the impedance and the objective function used by the optimizer is extremely flat and therefore sensitive to initial starting values. The discrepancies at frequencies beyond the cut on frequency of higher order duct modes are due to the assumption of only plane waves in the impedance eduction model, although higher order modes are propagating in the impedance tube facility.
Quantitative impedance measurements for eddy current model validation
NASA Astrophysics Data System (ADS)
Khan, T. A.; Nakagawa, N.
2000-05-01
This paper reports on a series of laboratory-based impedance measurement data, collected by the use of a quantitatively accurate, mechanically controlled measurement station. The purpose of the measurement is to validate a BEM-based eddy current model against experiment. We have therefore selected two "validation probes," which are both split-D differential probes. Their internal structures and dimensions are extracted from x-ray CT scan data, and thus known within the measurement tolerance. A series of measurements was carried out, using the validation probes and two Ti-6Al-4V block specimens, one containing two 1-mm long fatigue cracks, and the other containing six EDM notches of a range of sizes. Motor-controlled XY scanner performed raster scans over the cracks, with the probe riding on the surface with a spring-loaded mechanism to maintain the lift off. Both an impedance analyzer and a commercial EC instrument were used in the measurement. The probes were driven in both differential and single-coil modes for the specific purpose of model validation. The differential measurements were done exclusively by the eddyscope, while the single-coil data were taken with both the impedance analyzer and the eddyscope. From the single-coil measurements, we obtained the transfer function to translate the voltage output of the eddyscope into impedance values, and then used it to translate the differential measurement data into impedance results. The presentation will highlight the schematics of the measurement procedure, a representative of raw data, explanation of the post data-processing procedure, and then a series of resulting 2D flaw impedance results. A noise estimation will be given also, in order to quantify the accuracy of these measurements, and to be used in probability-of-detection estimation.—This work was supported by the NSF Industry/University Cooperative Research Program.
NASA Astrophysics Data System (ADS)
Zhao, Yanlin; Yao, Jun; Wang, Mi
2016-07-01
On-line monitoring of crystal size in the crystallization process is crucial to many pharmaceutical and fine-chemical industrial applications. In this paper, a novel method is proposed for the on-line monitoring of the cooling crystallization process of L-glutamic acid (LGA) using electrical impedance spectroscopy (EIS). The EIS method can be used to monitor the growth of crystal particles relying on the presence of an electrical double layer on the charged particle surface and the polarization of double layer under the excitation of alternating electrical field. The electrical impedance spectra and crystal size were measured on-line simultaneously by an impedance analyzer and focused beam reflectance measurement (FBRM), respectively. The impedance spectra were analyzed using the equivalent circuit model and the equivalent circuit elements in the model can be obtained by fitting the experimental data. Two equivalent circuit elements, including capacitance (C 2) and resistance (R 2) from the dielectric polarization of the LGA solution and crystal particle/solution interface, are in relation with the crystal size. The mathematical relationship between the crystal size and the equivalent circuit elements can be obtained by a non-linear fitting method. The function can be used to predict the change of crystal size during the crystallization process.
Instantaneous Respiratory Estimation from Thoracic Impedance by Empirical Mode Decomposition.
Wang, Fu-Tai; Chan, Hsiao-Lung; Wang, Chun-Li; Jian, Hung-Ming; Lin, Sheng-Hsiung
2015-07-07
Impedance plethysmography provides a way to measure respiratory activity by sensing the change of thoracic impedance caused by inspiration and expiration. This measurement imposes little pressure on the body and uses the human body as the sensor, thereby reducing the need for adjustments as body position changes and making it suitable for long-term or ambulatory monitoring. The empirical mode decomposition (EMD) can decompose a signal into several intrinsic mode functions (IMFs) that disclose nonstationary components as well as stationary components and, similarly, capture respiratory episodes from thoracic impedance. However, upper-body movements usually produce motion artifacts that are not easily removed by digital filtering. Moreover, large motion artifacts disable the EMD to decompose respiratory components. In this paper, motion artifacts are detected and replaced by the data mirrored from the prior and the posterior before EMD processing. A novel intrinsic respiratory reconstruction index that considers both global and local properties of IMFs is proposed to define respiration-related IMFs for respiration reconstruction and instantaneous respiratory estimation. Based on the experiments performing a series of static and dynamic physical activates, our results showed the proposed method had higher cross correlations between respiratory frequencies estimated from thoracic impedance and those from oronasal airflow based on small window size compared to the Fourier transform-based method.
Instantaneous Respiratory Estimation from Thoracic Impedance by Empirical Mode Decomposition
Wang, Fu-Tai; Chan, Hsiao-Lung; Wang, Chun-Li; Jian, Hung-Ming; Lin, Sheng-Hsiung
2015-01-01
Impedance plethysmography provides a way to measure respiratory activity by sensing the change of thoracic impedance caused by inspiration and expiration. This measurement imposes little pressure on the body and uses the human body as the sensor, thereby reducing the need for adjustments as body position changes and making it suitable for long-term or ambulatory monitoring. The empirical mode decomposition (EMD) can decompose a signal into several intrinsic mode functions (IMFs) that disclose nonstationary components as well as stationary components and, similarly, capture respiratory episodes from thoracic impedance. However, upper-body movements usually produce motion artifacts that are not easily removed by digital filtering. Moreover, large motion artifacts disable the EMD to decompose respiratory components. In this paper, motion artifacts are detected and replaced by the data mirrored from the prior and the posterior before EMD processing. A novel intrinsic respiratory reconstruction index that considers both global and local properties of IMFs is proposed to define respiration-related IMFs for respiration reconstruction and instantaneous respiratory estimation. Based on the experiments performing a series of static and dynamic physical activates, our results showed the proposed method had higher cross correlations between respiratory frequencies estimated from thoracic impedance and those from oronasal airflow based on small window size compared to the Fourier transform-based method. PMID:26198231
Frerichs, Inéz; Amato, Marcelo B P; van Kaam, Anton H; Tingay, David G; Zhao, Zhanqi; Grychtol, Bartłomiej; Bodenstein, Marc; Gagnon, Hervé; Böhm, Stephan H; Teschner, Eckhard; Stenqvist, Ola; Mauri, Tommaso; Torsani, Vinicius; Camporota, Luigi; Schibler, Andreas; Wolf, Gerhard K; Gommers, Diederik; Leonhardt, Steffen; Adler, Andy
2017-01-01
Electrical impedance tomography (EIT) has undergone 30 years of development. Functional chest examinations with this technology are considered clinically relevant, especially for monitoring regional lung ventilation in mechanically ventilated patients and for regional pulmonary function testing in patients with chronic lung diseases. As EIT becomes an established medical technology, it requires consensus examination, nomenclature, data analysis and interpretation schemes. Such consensus is needed to compare, understand and reproduce study findings from and among different research groups, to enable large clinical trials and, ultimately, routine clinical use. Recommendations of how EIT findings can be applied to generate diagnoses and impact clinical decision-making and therapy planning are required. This consensus paper was prepared by an international working group, collaborating on the clinical promotion of EIT called TRanslational EIT developmeNt stuDy group. It addresses the stated needs by providing (1) a new classification of core processes involved in chest EIT examinations and data analysis, (2) focus on clinical applications with structured reviews and outlooks (separately for adult and neonatal/paediatric patients), (3) a structured framework to categorise and understand the relationships among analysis approaches and their clinical roles, (4) consensus, unified terminology with clinical user-friendly definitions and explanations, (5) a review of all major work in thoracic EIT and (6) recommendations for future development (193 pages of online supplements systematically linked with the chief sections of the main document). We expect this information to be useful for clinicians and researchers working with EIT, as well as for industry producers of this technology. PMID:27596161
Chen, Peirong; Schönebaum, Simon; Simons, Thomas; Rauch, Dieter; Dietrich, Markus; Moos, Ralf; Simon, Ulrich
2015-01-01
Zeolites have been found to be promising sensor materials for a variety of gas molecules such as NH3, NOx, hydrocarbons, etc. The sensing effect results from the interaction of the adsorbed gas molecules with mobile cations, which are non-covalently bound to the zeolite lattice. The mobility of the cations can be accessed by electrical low-frequency (LF; mHz to MHz) and high-frequency (HF; GHz) impedance measurements. Recent developments allow in situ monitoring of catalytic reactions on proton-conducting zeolites used as catalysts. The combination of such in situ impedance measurements with diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS), which was applied to monitor the selective catalytic reduction of nitrogen oxides (DeNOx-SCR), not only improves our understanding of the sensing properties of zeolite catalysts from integral electric signal to molecular processes, but also bridges the length scales being studied, from centimeters to nanometers. In this work, recent developments of zeolite-based, impedimetric sensors for automotive exhaust gases, in particular NH3, are summarized. The electrical response to NH3 obtained from LF impedance measurements will be compared with that from HF impedance measurements, and correlated with the infrared spectroscopic characteristics obtained from the DRIFTS studies of molecules involved in the catalytic conversion. The future perspectives, which arise from the combination of these methods, will be discussed. PMID:26580627
Cho, Youngho; Hur, Kyeon; Kang, Yong; ...
2017-09-08
This study investigates the emerging harmonic stability concerns to be addressed by grid planners in generation interconnection studies, owing to the increased adoption of renewable energy resources connected to the grid via power electronic converters. The wideband and high-frequency electromagnetic transient (EMT) characteristics of these converter-interfaced generators (CIGs) and their interaction with the grid impedance are not accurately captured in the typical dynamic studies conducted by grid planners. This paper thus identifies the desired components to be studied and subsequently develops a practical process for integrating a new CIG into a grid with the existing CIGs. The steps of thismore » process are as follows: the impedance equation of a CIG using its control dynamics and an interface filter to the grid, for example, an LCL filter (inductor-capacitor-inductor type), is developed; an equivalent impedance model including the existing CIGs nearby and the grid observed from the point of common coupling are derived; the system stability for credible operating scenarios is assessed. Detailed EMT simulations validate the accuracy of the impedance models and stability assessment for various connection scenarios. Here, by complementing the conventional EMT simulation studies, the proposed analytical approach enables grid planners to identify critical design parameters for seamlessly integrating a new CIG and ensuring the reliability of the grid.« less
NASA Astrophysics Data System (ADS)
Alawasa, Khaled Mohammad
Voltage-source converters (VSCs) have gained widespread acceptance in modern power systems. The stability and dynamics of power systems involving these devices have recently become salient issues. In the small-signal sense, the dynamics of VSC-based systems is dictated by its incremental output impedance, which is formed by a combination of 'passive' circuit components and 'active' control elements. Control elements such as control parameters, control loops, and control topologies play a significant role in shaping the impedance profile. Depending on the control schemes and strategies used, VSC-based systems can exhibit different incremental impedance dynamics. As the control elements and dynamics are involved in the impedance structure, the frequency-dependent output impedance might have a negative real-part (i.e., a negative resistance). In the grid-connected mode, the negative resistance degrades the system damping and negatively impacts the stability. In high-voltage networks where high-power VSC-based systems are usually employed and where sub-synchronous dynamics usually exist, integrating large VSC-based systems might reduce the overall damping and results in unstable dynamics. The objectives of this thesis are to (1) investigate and analyze the output impedance properties under different control strategies and control functions, (2) identify and characterize the key contributors to the impedance and sub-synchronous damping profiles, and (3) propose mitigation techniques to minimize and eliminate the negative impact associated with integrating VSC-based systems into power systems. Different VSC configurations are considered in this thesis; in particular, the full-scale and partial-scale topologies (doubly fed-induction generators) are addressed. Additionally, the impedance and system damping profiles are studied under two different control strategies: the standard vector control strategy and the recently-developed power synchronization control strategy. Furthermore, this thesis proposes a simple and robust technique for damping the sub-synchronous resonance in a power system.
Tax, Chantal M. W.; Chamberland, Maxime; van Stralen, Marijn; Viergever, Max A.; Whittingstall, Kevin; Fortin, David; Descoteaux, Maxime; Leemans, Alexander
2015-01-01
Fiber tractography plays an important role in exploring the architectural organization of fiber trajectories, both in fundamental neuroscience and in clinical applications. With the advent of diffusion MRI (dMRI) approaches that can also model “crossing fibers”, the complexity of the fiber network as reconstructed with tractography has increased tremendously. Many pathways interdigitate and overlap, which hampers an unequivocal 3D visualization of the network and impedes an efficient study of its organization. We propose a novel fiber tractography visualization approach that interactively and selectively adapts the transparency rendering of fiber trajectories as a function of their orientation to enhance the visibility of the spatial context. More specifically, pathways that are oriented (locally or globally) along a user-specified opacity axis can be made more transparent or opaque. This substantially improves the 3D visualization of the fiber network and the exploration of tissue configurations that would otherwise be largely covered by other pathways. We present examples of fiber bundle extraction and neurosurgical planning cases where the added benefit of our new visualization scheme is demonstrated over conventional fiber visualization approaches. PMID:26444010
Sagar, Vidya; Atluri, V. S. R.; Tomitaka, A.; Shah, P.; Nagasetti, A.; Pilakka-Kanthikeel, S.; El-Hage, N.; McGoron, A.; Takemura, Y.; Nair, M.
2016-01-01
Combined treatment strategies based on magnetic nanoparticles (MNPs) with near infrared ray (NIR) biophotonic possess tremendous potential for non-invasive therapeutic approach. Nonetheless, investigations in this direction have been limited to peripheral body region and little is known about the potential biomedical application of this approach for brain. Here we report that transient NIR exposure is dissipation-free and has no adverse effect on the viability and plasticity of major brain cells in the presence or absence superparamagnetic nanoparticles. The 808 nm NIR laser module with thermocouple was employed for functional studies upon NIR exposure to brain cells. Magnetic nanoparticles were characterized using transmission electron microscopy (TEM), X-ray diffraction (XRD), dynamic laser scattering (DLS), and vibrating sample magnetometer (VSM). Brain cells viability and plasticity were analyzed using electric cell-substrate impedance sensing system, cytotoxicity evaluation, and confocal microscopy. When efficacious non-invasive photobiomodulation and neuro-therapeutical targeting and monitoring to brain remain a formidable task, the discovery of this dissipation-free, transient NIR photonic approach for brain cells possesses remarkable potential to add new dimension. PMID:27465276
Implications of the Hierarchical Structure of Psychopathology for Psychiatric Neuroimaging.
Zald, David H; Lahey, Benjamin B
2017-05-01
Research into the neurobiological substrates of psychopathology has been impeded by heterogeneity within diagnostic categories, comorbidity among mental disorders, and the presence of symptoms that transcend diagnostic categories. Solutions to these issues increasingly focus neurobiological research on isolated or narrow groupings of symptoms or functional constructs rather than categorical diagnoses. Here we argue for a more integrative approach that also incorporates the broad hierarchical structure of psychopathological symptoms and their etiological mechanisms. This approach places clinical neuroscience research in the context of a hierarchy of empirically defined factors of symptoms such as internalizing disorders, externalizing disorders, and the general factor of psychopathology. Application of this hierarchical approach has the potential to reveal neural substrates that nonspecifically contribute to multiple forms of psychopathology and their comorbidity, and in doing so, facilitate the study of mechanisms that are specific to single dimensions and subsets of symptoms. Neurobiological research on the hierarchy of dimensions of psychopathology is only just beginning to emerge, but has the potential to radically alter our understanding of the neurobiology of abnormal behavior.
The effect of respiratory oscillations in heart rate on detrended fluctuation analysis
NASA Astrophysics Data System (ADS)
Govindan, Rathinaswamy B.; Kota, Srinivas; Al-Shargabi, Tareq; Swisher, Christopher B.; du Plessis, Adre
2017-10-01
Characterization of heart rate using detrended fluctuation analysis (DFA) is impeded by respiratory oscillations. In particular, the short-term exponent measured from 15 to 30 beats is compromised in the DFA. We reconstruct respiratory signal from electrocardiograms and attenuate the respiratory oscillation in the heart rate using a frequency-dependent subtraction approach. We validate this method by applying it to an electrocardiogram signal simulated using a coupled differential equation with the respiratory oscillation modelled using a sine function. The exponent estimated using the proposed approach agreed with the exponent incorporated in the model within a narrow range. In contrast, the exponent obtained from the raw data deviated from the expected value. Furthermore, the exponents obtained for the raw heart rate are smaller than the exponents obtained for the respiration oscillation attenuated heart rate. We apply this approach to heart rate measured from 12 preterm infants that were being treated for prematurity related complications. As observed in the simulated data, we show that compared to the raw heart rate, the respiratory oscillation attenuated heart rate shows higher short-term exponent (p < 0.001).
Sagar, Vidya; Atluri, V S R; Tomitaka, A; Shah, P; Nagasetti, A; Pilakka-Kanthikeel, S; El-Hage, N; McGoron, A; Takemura, Y; Nair, M
2016-07-28
Combined treatment strategies based on magnetic nanoparticles (MNPs) with near infrared ray (NIR) biophotonic possess tremendous potential for non-invasive therapeutic approach. Nonetheless, investigations in this direction have been limited to peripheral body region and little is known about the potential biomedical application of this approach for brain. Here we report that transient NIR exposure is dissipation-free and has no adverse effect on the viability and plasticity of major brain cells in the presence or absence superparamagnetic nanoparticles. The 808 nm NIR laser module with thermocouple was employed for functional studies upon NIR exposure to brain cells. Magnetic nanoparticles were characterized using transmission electron microscopy (TEM), X-ray diffraction (XRD), dynamic laser scattering (DLS), and vibrating sample magnetometer (VSM). Brain cells viability and plasticity were analyzed using electric cell-substrate impedance sensing system, cytotoxicity evaluation, and confocal microscopy. When efficacious non-invasive photobiomodulation and neuro-therapeutical targeting and monitoring to brain remain a formidable task, the discovery of this dissipation-free, transient NIR photonic approach for brain cells possesses remarkable potential to add new dimension.
NASA Astrophysics Data System (ADS)
Sagar, Vidya; Atluri, V. S. R.; Tomitaka, A.; Shah, P.; Nagasetti, A.; Pilakka-Kanthikeel, S.; El-Hage, N.; McGoron, A.; Takemura, Y.; Nair, M.
2016-07-01
Combined treatment strategies based on magnetic nanoparticles (MNPs) with near infrared ray (NIR) biophotonic possess tremendous potential for non-invasive therapeutic approach. Nonetheless, investigations in this direction have been limited to peripheral body region and little is known about the potential biomedical application of this approach for brain. Here we report that transient NIR exposure is dissipation-free and has no adverse effect on the viability and plasticity of major brain cells in the presence or absence superparamagnetic nanoparticles. The 808 nm NIR laser module with thermocouple was employed for functional studies upon NIR exposure to brain cells. Magnetic nanoparticles were characterized using transmission electron microscopy (TEM), X-ray diffraction (XRD), dynamic laser scattering (DLS), and vibrating sample magnetometer (VSM). Brain cells viability and plasticity were analyzed using electric cell-substrate impedance sensing system, cytotoxicity evaluation, and confocal microscopy. When efficacious non-invasive photobiomodulation and neuro-therapeutical targeting and monitoring to brain remain a formidable task, the discovery of this dissipation-free, transient NIR photonic approach for brain cells possesses remarkable potential to add new dimension.
Implications of the Hierarchical Structure of Psychopathology for Psychiatric Neuroimaging
Zald, David H.; Lahey, Benjamin B.
2017-01-01
Research into the neurobiological substrates of psychopathology has been impeded by heterogeneity within diagnostic categories, comorbidity among mental disorders, and the presence of symptoms that transcend diagnostic categories. Solutions to these issues increasingly focus neurobiological research on isolated or narrow groupings of symptoms or functional constructs rather than categorical diagnoses. Here we argue for a more integrative approach that also incorporates the broad hierarchical structure of psychopathological symptoms and their etiological mechanisms. This approach places clinical neuroscience research in the context of a hierarchy of empirically defined factors of symptoms such as internalizing disorders, externalizing disorders, and the general factor of psychopathology. Application of this hierarchical approach has the potential to reveal neural substrates that nonspecifically contribute to multiple forms of psychopathology and their comorbidity, and in doing so, facilitate the study of mechanisms that are specific to single dimensions and subsets of symptoms. Neurobiological research on the hierarchy of dimensions of psychopathology is only just beginning to emerge, but has the potential to radically alter our understanding of the neurobiology of abnormal behavior. PMID:28713866
Tax, Chantal M W; Chamberland, Maxime; van Stralen, Marijn; Viergever, Max A; Whittingstall, Kevin; Fortin, David; Descoteaux, Maxime; Leemans, Alexander
2015-01-01
Fiber tractography plays an important role in exploring the architectural organization of fiber trajectories, both in fundamental neuroscience and in clinical applications. With the advent of diffusion MRI (dMRI) approaches that can also model "crossing fibers", the complexity of the fiber network as reconstructed with tractography has increased tremendously. Many pathways interdigitate and overlap, which hampers an unequivocal 3D visualization of the network and impedes an efficient study of its organization. We propose a novel fiber tractography visualization approach that interactively and selectively adapts the transparency rendering of fiber trajectories as a function of their orientation to enhance the visibility of the spatial context. More specifically, pathways that are oriented (locally or globally) along a user-specified opacity axis can be made more transparent or opaque. This substantially improves the 3D visualization of the fiber network and the exploration of tissue configurations that would otherwise be largely covered by other pathways. We present examples of fiber bundle extraction and neurosurgical planning cases where the added benefit of our new visualization scheme is demonstrated over conventional fiber visualization approaches.
A High Input Impedance Low Noise Integrated Front-End Amplifier for Neural Monitoring.
Zhou, Zhijun; Warr, Paul A
2016-12-01
Within neural monitoring systems, the front-end amplifier forms the critical element for signal detection and pre-processing, which determines not only the fidelity of the biosignal, but also impacts power consumption and detector size. In this paper, a novel combined feedback loop-controlled approach is proposed to compensate for input leakage currents generated by low noise amplifiers when in integrated circuit form alongside signal leakage into the input bias network. This loop topology ensures the Front-End Amplifier (FEA) maintains a high input impedance across all manufacturing and operational variations. Measured results from a prototype manufactured on the AMS 0.35 [Formula: see text] CMOS technology is provided. This FEA consumes 3.1 [Formula: see text] in 0.042 [Formula: see text], achieves input impedance of 42 [Formula: see text], and 18.2 [Formula: see text] input-referred noise.
Zhou, Lian; Zhu, Shanan
2014-01-01
Magnetoacoustic tomography with Magnetic Induction (MAT-MI) is a noninvasive electrical conductivity imaging approach that measures ultrasound wave induced by magnetic stimulation, for reconstructing the distribution of electrical impedance in biological tissue. Existing reconstruction algorithms for MAT-MI are based on the assumption that the acoustic properties in the tissue are homogeneous. However, the tissue in most parts of human body, has heterogeneous acoustic properties, which leads to potential distortion and blurring of small buried objects in the impedance images. In the present study, we proposed a new algorithm for MAT-MI to image the impedance distribution in tissues with inhomogeneous acoustic speed distributions. With a computer head model constructed from MR images of a human subject, a series of numerical simulation experiments were conducted. The present results indicate that the inhomogeneous acoustic properties of tissues in terms of speed variation can be incorporated in MAT-MI imaging. PMID:24845284
NASA Astrophysics Data System (ADS)
Yuan, Wen-Xiang
2012-03-01
The frequency dependence of electric modulus of polycrystalline CaCu3Ti4O12 (CCTO) ceramics has been investigated. The experimental data have also been analyzed in the complex plane of impedance and electric modulus, and a suitable equivalent circuit has been proposed to explain the dielectric response. Four dielectric responses are first distinguished in the impedance and modulus spectroscopies. The results are well interpreted in terms of a triple insulating barrier capacitor model. Using this model, these four dielectric relaxations are attributed to the domain, domain-boundary, grain-boundary, and surface layer effects with three Maxwell-Wagner relaxations. Moreover, the values of the resistance and capacitance of bulk CCTO phase, domain-boundary, grain-boundary and surface layer contributions have been calculated directly from the peak characteristics of spectroscopic plots.
Carminati, Marco; Ferrari, Giorgio; Sampietro, Marco
2009-12-01
We present an instrument that enables electrochemical measurements (cyclic voltammetry, impedance tracking, and impedance spectroscopy) on submicrometric samples. The system features a frequency range from dc to 1 MHz and a current resolution of 10 fA for a measurement time of 1 s, giving a sensitivity of few attofarads in terms of measurable capacitance with an applied voltage of only 100 mV. These performances are obtained using a low-noise wide-bandwidth integrator/differentiator stage to sense the input current and a modular approach to minimize the effect of input stray capacitances. A digitally implemented lock-in filter optimally extracts the impedance of the sample, providing time tracking and spectroscopy operating modes. This computer-based and flexible instrument is well suited for characterizing and tracking the electrical properties of biomolecules kept in the physiological solution down to the nanoscale.
Crosstalk compensation in analysis of energy storage devices
Christophersen, Jon P; Morrison, John L; Morrison, William H; Motloch, Chester G; Rose, David M
2014-06-24
Estimating impedance of energy storage devices includes generating input signals at various frequencies with a frequency step factor therebetween. An excitation time record (ETR) is generated to include a summation of the input signals and a deviation matrix of coefficients is generated relative to the excitation time record to determine crosstalk between the input signals. An energy storage device is stimulated with the ETR and simultaneously a response time record (RTR) is captured that is indicative of a response of the energy storage device to the ETR. The deviation matrix is applied to the RTR to determine an in-phase component and a quadrature component of an impedance of the energy storage device at each of the different frequencies with the crosstalk between the input signals substantially removed. This approach enables rapid impedance spectra measurements that can be completed within one period of the lowest frequency or less.
Design and calibration of a high-frequency oscillatory ventilator.
Simon, B A; Mitzner, W
1991-02-01
High-frequency ventilation (HFV) is a modality of mechanical ventilation which presents difficult technical demands to the clinical or laboratory investigator. The essential features of an ideal HFV system are described, including wide frequency range, control of tidal volume and mean airway pressure, minimal dead space, and high effective internal impedance. The design and performance of a high-frequency oscillatory ventilation system is described which approaches these requirements. The ventilator utilizes a linear motor regulated by a closed loop controller and driving a novel frictionless double-diaphragm piston pump. Finally, the ventilator performance is tested using the impedance model of Venegas [1].
Jaffrin, M Y; Maasrani, M; Le Gourrier, A; Boudailliez, B
1997-05-01
A method is presented for monitoring the relative variation of extracellular and intracellular fluid volumes using a multifrequency impedance meter and the Cole-Cole extrapolation technique. It is found that this extrapolation is necessary to obtain reliable data for the resistance of the intracellular fluid. The extracellular and intracellular resistances can be approached using frequencies of, respectively, 5 kHz and 1000 kHz, but the use of 100 kHz leads to unacceptable errors. In the conventional treatment the overall relative variation of intracellular resistance is found to be relatively small.
New Approaches in Force-Limited Vibration Testing of Flight Hardware
NASA Technical Reports Server (NTRS)
Kolaini, Ali R.; Kern, Dennis L.
2012-01-01
To qualify flight hardware for random vibration environments the following methods are used to limit the loads in the aerospace industry: (1) Response limiting and notching (2) Simple TDOF model (3) Semi-empirical force limits (4) Apparent mass, etc. and (5) Impedance method. In all these methods attempts are made to remove conservatism due to the mismatch in impedances between the test and the flight configurations of the hardware that are being qualified. Assumption is the hardware interfaces have correlated responses. A new method that takes into account the un-correlated hardware interface responses are described in this presentation.
Hébert, Clément; Cottance, Myline; Degardin, Julie; Scorsone, Emmanuel; Rousseau, Lionel; Lissorgues, Gaelle; Bergonzo, Philippe; Picaud, Serge
2016-12-01
Nanocrystalline Boron doped Diamond proved to be a very attractive material for neural interfacing, especially with the retina, where reduce glia growth is observed with respect to other materials, thus facilitating neuro-stimulation over long terms. In the present study, we integrated diamond microelectrodes on a polyimide substrate and investigated their performances for the development of neural prosthesis. A full description of the microfabrication of the implants is provided and their functionalities are assessed using cyclic voltammetry and electrochemical impedance spectroscopy. A porous structure of the electrode surface was thus revealed and showed promising properties for neural recording or stimulation. Using the flexible implant, we showed that is possible to follow in vivo the evolution of the electric contact between the diamond electrodes and the retina over 4months by using electrochemical impedance spectroscopy. The position of the implant was also monitored by optical coherence tomography to corroborate the information given by the impedance measurements. The results suggest that diamond microelectrodes are very good candidates for retinal prosthesis. Copyright © 2016. Published by Elsevier B.V.
Electrical and absorption properties of fresh cassava tubers and cassava starch
NASA Astrophysics Data System (ADS)
Harnsoongnoen, S.; Siritaratiwat, A.
2015-09-01
The objective of this study was to analyze the electrical and absorption properties of fresh cassava tubers and cassava starch at various frequencies using electric impedance spectroscopy and near-infrared spectroscopy, as well as determine the classification of the electrical parameters of both materials using the principle component analysis (PCA) method. All samples were measured at room temperature. The electrical and absorption parameters consisted of dielectric constant, dissipation factor, parallel capacitance, resistance, reactance, impedance and absorbance. It was found that the electrical and absorption properties of fresh cassava tubers and cassava starch were a function of frequency, and there were significant differences between the materials. The dielectric constant, parallel capacitance, resistance and impedance of fresh cassava tubers and cassava starch had similar dramatic decreases with increasing frequency. However, the reactance of both materials increased with an increasing frequency. The electrical parameters of both materials could be classified into two groups. Moreover, the dissipation factor and phase of impedance were the parameters that could be used in the separation of both materials. According to the absorbance patterns of the fresh cassava tubers and cassava starch, there were significant differences.
Hartmann, C J; Wojtecki, L; Vesper, J; Volkmann, J; Groiss, S J; Schnitzler, A; Südmeyer, M
2015-10-01
This study was conducted to better understand the development of clinical efficacy and impedance levels in the long-term course of deep brain stimulation (DBS) of the subthalamic nucleus (STN) in Parkinson's disease (PD). In this retrospective study of twenty PD patients, the motor part of the Unified Parkinson's Disease Rating Scale was periodically assessed i) after withdrawal of medication and inactivated stimulation, ii) after withdrawal of medication with activated stimulation and iii) after challenge with l-Dopa during activated stimulation up to 13 years after surgery. STN-DBS with or without medication significantly improved motor function up to 13 years after surgery. The contribution of axial symptoms increased over time. While the stimulation parameters were kept constant, the therapeutic impedances progressively declined. STN-DBS in PD remains effective in the long-term course of the disease. Constant current stimulation might be preferable over voltage-controlled stimulation, as it would alleviate the impact of impedance changes on the volume of tissue activated. Copyright © 2015 Elsevier Ltd. All rights reserved.
Disc piezoelectric ceramic transformers.
Erhart, Jirií; Půlpán, Petr; Doleček, Roman; Psota, Pavel; Lédl, Vít
2013-08-01
In this contribution, we present our study on disc-shaped and homogeneously poled piezoelectric ceramic transformers working in planar-extensional vibration modes. Transformers are designed with electrodes divided into wedge, axisymmetrical ring-dot, moonie, smile, or yin-yang segments. Transformation ratio, efficiency, and input and output impedances were measured for low-power signals. Transformer efficiency and transformation ratio were measured as a function of frequency and impedance load in the secondary circuit. Optimum impedance for the maximum efficiency has been found. Maximum efficiency and no-load transformation ratio can reach almost 100% and 52 for the fundamental resonance of ring-dot transformers and 98% and 67 for the second resonance of 2-segment wedge transformers. Maximum efficiency was reached at optimum impedance, which is in the range from 500 Ω to 10 kΩ, depending on the electrode pattern and size. Fundamental vibration mode and its overtones were further studied using frequency-modulated digital holographic interferometry and by the finite element method. Complementary information has been obtained by the infrared camera visualization of surface temperature profiles at higher driving power.
Sifrim, Daniel; Tutuian, Radu
2005-03-01
In a subgroup of patients with non-erosive gastroesophageal reflux disease (GORD) or mild oesophagitis, acid clearance is prolonged in spite of favourable gravity and normal or minimally impaired oesophageal peristalsis. Dysphagia is rare in this group but might also be present or develop after anti-reflux surgery. The causal relationship between prolonged clearance or dysphagia and oesophageal body dysmotility in these patients is not completely clear. New techniques are now available to assess oesophageal motility and transit and might help to detect more subtle defects underlying functional impairment in patients with GORD. Combined video-fluoroscopy and intraluminal impedance indicate an excellent correlation between both methods in detecting oesophageal bolus transit. Combined intraluminal impedance and manometry has the capability to evaluate oesophageal contractions and bolus transit without the use of radiation. Subtle bolus transit abnormalities were identified in a small proportion of patients with mild oesophagits and normal oesophageal peristalsis. Outcome data are needed to evaluate the prognostic value of combined manometry-impedance in patients with GORD undergoing anti-reflux surgery.
NASA Astrophysics Data System (ADS)
Qin, F. X.; Peng, H. X.; Popov, V. V.; Phan, M. H.
2011-02-01
Composites consisting of glass-coated amorphous microwire Co 68.59Fe 4.84Si 12.41B 14.16 and 913 E-glass prepregs were designed and fabricated. The influences of tensile stress, annealing and number of composite layers on the giant magneto-impedance (GMI) and giant stress-impedance (GSI) effects in these composites were investigated systematically. It was found that the application of tensile stress along the microwire axis or an increase in the number of composite layers reduced the GMI effect and increased the circular anisotropy field, while the annealing treatment had a reverse effect. The value of matrix-wire interfacial stress calculated via the GMI profiles coincided with the value of the applied effective tensile stress to yield similar GMI profiles. Enhancement of the GSI effect was achieved in the composites relative to their single microwire inclusion. These findings are important for the development of functional microwire-based composites for magnetic- and stress-sensing applications. They also open up a new route for probing the interfacial stress in fibre-reinforced polymer (FRP) composites.
28 CFR 0.111 - General functions.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... (b) The service of all civil and criminal process emanating from the Federal judicial system... psychological well-being and social adjustment of such persons, pursuant to 18 U.S.C. 3521, et seq., and... intimidation impedes the functioning of the Federal judicial process. (f) Provision of assistance in the...
Mendoza, Marco; Bonilla, Isela; González-Galván, Emilio; Reyes, Fernando
2016-01-01
This paper presents an improved wave-based bilateral teleoperation scheme for rehabilitation therapies assisted by robot manipulators. The main feature of this bilateral teleoperator is that both robot manipulators, master and slave, are controlled by impedance. Thus, a pair of motion-based adaptive impedance controllers are integrated into a wave-based configuration, in order to guarantee a stable human-robot interaction and to compensate the position drift, characteristic of the available schemes of bilateral teleoperation. Moreover, the teleoperator stability, in the presence of time delays in the communication channel, is guaranteed because the wave-variable approach is included to encode the force and velocity signals. It should be noted that the proposed structure enables the implementation of several teleoperator schemes, from passive therapies, without the intervention of a human operator on the master side, to fully active therapies where both manipulators interact with humans in a stable manner. The suitable performance of the proposed teleoperator is verified through some results obtained from the simulation of the passive and active-constrained modes, by considering typical tasks in motor-therapy rehabilitation, where an improved behavior is observed when compared to implementations of the classical wave-based approach. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Yang, Yaowen; Divsholi, Bahador Sabet
2010-01-01
The electromechanical (EM) impedance technique using piezoelectric lead zirconate titanate (PZT) transducers for structural health monitoring (SHM) has attracted considerable attention in various engineering fields. In the conventional EM impedance technique, the EM admittance of a PZT transducer is used as a damage indicator. Statistical analysis methods such as root mean square deviation (RMSD) have been employed to associate the damage level with the changes in the EM admittance signatures, but it is difficult to determine the location of damage using such methods. This paper proposes a new approach by dividing the large frequency (30–400 kHz) range into sub-frequency intervals and calculating their respective RMSD values. The RMSD of the sub-frequency intervals (RMSD-S) will be used to study the severity and location of damage. An experiment is carried out on a real size concrete structure subjected to artificial damage. It is observed that damage close to the PZT changes the high frequency range RMSD-S significantly, while the damage far away from the PZT changes the RMSD-S in the low frequency range significantly. The relationship between the frequency range and the PZT sensing region is also presented. Finally, a damage identification scheme is proposed to estimate the location and severity of damage in concrete structures. PMID:22163548
NASA Astrophysics Data System (ADS)
Farmann, Alexander; Waag, Wladislaw; Sauer, Dirk Uwe
2015-12-01
Robust algorithms using reduced order equivalent circuit model (ECM) for an accurate and reliable estimation of battery states in various applications become more popular. In this study, a novel adaptive, self-learning heuristic algorithm for on-board impedance parameters and voltage estimation of lithium-ion batteries (LIBs) in electric vehicles is introduced. The presented approach is verified using LIBs with different composition of chemistries (NMC/C, NMC/LTO, LFP/C) at different aging states. An impedance-based reduced order ECM incorporating ohmic resistance and a combination of a constant phase element and a resistance (so-called ZARC-element) is employed. Existing algorithms in vehicles are much more limited in the complexity of the ECMs. The algorithm is validated using seven day real vehicle data with high temperature variation including very low temperatures (from -20 °C to +30 °C) at different Depth-of-Discharges (DoDs). Two possibilities to approximate both ZARC-elements with finite number of RC-elements on-board are shown and the results of the voltage estimation are compared. Moreover, the current dependence of the charge-transfer resistance is considered by employing Butler-Volmer equation. Achieved results indicate that both models yield almost the same grade of accuracy.
AC-impedance measurements during thermal runaway process in several lithium/polymer batteries
NASA Astrophysics Data System (ADS)
Uchida, I.; Ishikawa, H.; Mohamedi, M.; Umeda, M.
In this work, we present a set of thermal characterization experiments of charged prismatic polymer lithium-ion battery (PLB) comparatively with those of a lithium-ion battery (LIB). These cells at different state of charge (SOC) were tested inside an accelerated rate calorimeter (ARC) to determine the onset-of-thermal runaway (OTR) temperatures. In addition, the thermally activated components of these cells were followed by monitoring the impedance (at 1 kHz) and the open-circuit voltage (OCV) as a function of temperature. An increase in the impedance was observed at around 133 °C corresponding to the polyethylene separator shutdown. Above 140 °C, the OCV dropped to zero indicating an internal short-circuit due the separator meltdown suggesting that the pinholes created in the separator at meltdown are large enough to create an internal short-circuit.
Input impedance of a probe-fed circular microstrip antenna with thick substrate
NASA Technical Reports Server (NTRS)
Davidovitz, M.; Lo, Y. T.
1986-01-01
A method of computing the input impedance for the probe fed circular microstrip antenna with thick dielectric substrate is presented. Utilizing the framework of the cavity model, the fields under the microstrip patch are expanded in a set of modes satisfying the boundary conditions on the eccentrically located probe, as well as on the cavity magnetic wall. A mode-matching technique is used to solve for the electric field at the junction between the cavity and the coaxial feed cable. The reflection coefficient of the transverse electromagnetic (TEM) mode incident in the coaxial cable is determined, from which the input impedance of the antenna is computed. Measured data are presented to verify the theoretical calculations. Results of the computation of various losses for the circular printed antenna as a function of substrate thickness are also included.
Changes in impedance of Ni/Cd cells with voltage and cycle life
NASA Technical Reports Server (NTRS)
Reid, Margaret A.
1992-01-01
Impedances of aerospace design Super Ni/Cd cells are being measured as functions of voltage and number of cycles. The cells have been cycled over 4400 cycles to date. Analysis of the impedance data has been made using a number of equivalent circuits. The model giving the best fit over the whole range of voltage has a parallel circuit of a kinetic resistance and a constant phase element in series with the ohmic resistance. The values for the circuit elements have been treated as empirical parameters, and no attempt has been made as yet to correlate them with physical and chemical changes in the electrode. No significant changes have been seen as yet with the exception of a decrease in kinetic resistance at low states of charge in the first 500 cycles.
Damage Diagnosis in Semiconductive Materials Using Electrical Impedance Measurements
NASA Technical Reports Server (NTRS)
Ross, Richard W.; Hinton, Yolanda L.
2008-01-01
Recent aerospace industry trends have resulted in an increased demand for real-time, effective techniques for in-flight structural health monitoring. A promising technique for damage diagnosis uses electrical impedance measurements of semiconductive materials. By applying a small electrical current into a material specimen and measuring the corresponding voltages at various locations on the specimen, changes in the electrical characteristics due to the presence of damage can be assessed. An artificial neural network uses these changes in electrical properties to provide an inverse solution that estimates the location and magnitude of the damage. The advantage of the electrical impedance method over other damage diagnosis techniques is that it uses the material as the sensor. Simple voltage measurements can be used instead of discrete sensors, resulting in a reduction in weight and system complexity. This research effort extends previous work by employing finite element method models to improve accuracy of complex models with anisotropic conductivities and by enhancing the computational efficiency of the inverse techniques. The paper demonstrates a proof of concept of a damage diagnosis approach using electrical impedance methods and a neural network as an effective tool for in-flight diagnosis of structural damage to aircraft components.
Recent advances in diagnostic testing for gastroesophageal reflux disease.
Naik, Rishi D; Vaezi, Michael F
2017-06-01
Gastroesophageal reflux disease (GERD) has a large economic burden with important complications that include esophagitis, Barrett's esophagus, and adenocarcinoma. Despite endoscopy, validated patient questionnaires, and traditional ambulatory pH monitoring, the diagnosis of GERD continues to be challenging. Areas covered: This review will explore the difficulties in diagnosing GERD with a focus on new developments, ranging from basic fundamental changes (histology and immunohistochemistry) to direct patient care (narrow-band imaging, impedance, and response to anti-reflux surgery). We searched PubMed using the noted keywords. We included data from full-text articles published in English. Further relevant articles were identified from the reference lists of review articles. Expert commentary: Important advances in novel parameters in intraluminal impedance monitoring such as baseline impedance monitoring has created some insight into alternative diagnostic strategies in GERD. Recent advances in endoscopic assessment of esophageal epithelial integrity via mucosal impedance measurement is questioning the paradigm of prolonged ambulatory testing for GERD. The future of reflux diagnosis may very well be without the need for currently employed technologies and could be as simple as assessing changes in epithelia integrity as a surrogate marker for GERD. However, future studies must validate such an approach.
Ovonic type switching in tin selenide thin films
NASA Technical Reports Server (NTRS)
Baxter, C. R.; Mclennan, W. D.
1975-01-01
Amorphous tin selenide thin films which possess Ovonic type switching properties are fabricated using vacuum deposition techniques. The devices are fabricated in a planar configuration and consist of amorphous tin selenide deposited over silver contacts. Results obtained indicate that Ovonic type memory switching does occur in these films with the energy density required for switching from a high impedance to a low impedance state being dependent on the spacing between the electrodes of the device. There is also a strong implication that the switching is a function of the magnitude of the applied voltage pulse.
NASA Technical Reports Server (NTRS)
1996-01-01
Under contract to Johnson Space Center, the University of Minnesota developed the concept of impedance cardiography as an alternative to thermodilution to access astronaut heart function in flight. NASA then contracted Space Labs, Inc. to construct miniature space units based on this technology. Several companies then launched their own impedance cardiography, including Renaissance Technologies, which manufactures the IQ System. The IQ System is 5 to 17 times cheaper than thermodilution, and features the signal processing technology called TFD (Time Frequency Distribution). TFD provides three- dimensional distribution of the blood circulation force signals, allowing visualization of changes in power, frequency and time.
A Two-dimensional Version of the Niblett-Bostick Transformation for Magnetotelluric Interpretations
NASA Astrophysics Data System (ADS)
Esparza, F.
2005-05-01
An imaging technique for two-dimensional magnetotelluric interpretations is developed following the well known Niblett-Bostick transformation for one-dimensional profiles. The algorithm uses a Hopfield artificial neural network to process series and parallel magnetotelluric impedances along with their analytical influence functions. The adaptive, weighted average approximation preserves part of the nonlinearity of the original problem. No initial model in the usual sense is required for the recovery of a functional model. Rather, the built-in relationship between model and data considers automatically, all at the same time, many half spaces whose electrical conductivities vary according to the data. The use of series and parallel impedances, a self-contained pair of invariants of the impedance tensor, avoids the need to decide on best angles of rotation for TE and TM separations. Field data from a given profile can thus be fed directly into the algorithm without much processing. The solutions offered by the Hopfield neural network correspond to spatial averages computed through rectangular windows that can be chosen at will. Applications of the algorithm to simple synthetic models and to the COPROD2 data set illustrate the performance of the approximation.
NASA Astrophysics Data System (ADS)
Malaga, Karlo A.; Schroeder, Karen E.; Patel, Paras R.; Irwin, Zachary T.; Thompson, David E.; Bentley, J. Nicole; Lempka, Scott F.; Chestek, Cynthia A.; Patil, Parag G.
2016-02-01
Objective. We characterized electrode stability over twelve weeks of impedance and neural recording data from four chronically-implanted Utah arrays in two rhesus macaques, and investigated the effects of glial scarring and interface interactions at the electrode recording site on signal quality using a computational model. Approach. A finite-element model of a Utah array microelectrode in neural tissue was coupled with a multi-compartmental model of a neuron to quantify the effects of encapsulation thickness, encapsulation resistivity, and interface resistivity on electrode impedance and waveform amplitude. The coupled model was then reconciled with the in vivo data. Histology was obtained seventeen weeks post-implantation to measure gliosis. Main results. From week 1-3, mean impedance and amplitude increased at rates of 115.8 kΩ/week and 23.1 μV/week, respectively. This initial ramp up in impedance and amplitude was observed across all arrays, and is consistent with biofouling (increasing interface resistivity) and edema clearing (increasing tissue resistivity), respectively, in the model. Beyond week 3, the trends leveled out. Histology showed that thin scars formed around the electrodes. In the model, scarring could not match the in vivo data. However, a thin interface layer at the electrode tip could. Despite having a large effect on impedance, interface resistivity did not have a noticeable effect on amplitude. Significance. This study suggests that scarring does not cause an electrical problem with regard to signal quality since it does not appear to be the main contributor to increasing impedance or significantly affect amplitude unless it displaces neurons. This, in turn, suggests that neural signals can be obtained reliably despite scarring as long as the recording site has sufficiently low impedance after accumulating a thin layer of biofouling. Therefore, advancements in microelectrode technology may be expedited by focusing on improvements to the recording site-tissue interface rather than elimination of the glial scar.
A FEM-based method to determine the complex material properties of piezoelectric disks.
Pérez, N; Carbonari, R C; Andrade, M A B; Buiochi, F; Adamowski, J C
2014-08-01
Numerical simulations allow modeling piezoelectric devices and ultrasonic transducers. However, the accuracy in the results is limited by the precise knowledge of the elastic, dielectric and piezoelectric properties of the piezoelectric material. To introduce the energy losses, these properties can be represented by complex numbers, where the real part of the model essentially determines the resonance frequencies and the imaginary part determines the amplitude of each resonant mode. In this work, a method based on the Finite Element Method (FEM) is modified to obtain the imaginary material properties of piezoelectric disks. The material properties are determined from the electrical impedance curve of the disk, which is measured by an impedance analyzer. The method consists in obtaining the material properties that minimize the error between experimental and numerical impedance curves over a wide range of frequencies. The proposed methodology starts with a sensitivity analysis of each parameter, determining the influence of each parameter over a set of resonant modes. Sensitivity results are used to implement a preliminary algorithm approaching the solution in order to avoid the search to be trapped into a local minimum. The method is applied to determine the material properties of a Pz27 disk sample from Ferroperm. The obtained properties are used to calculate the electrical impedance curve of the disk with a Finite Element algorithm, which is compared with the experimental electrical impedance curve. Additionally, the results were validated by comparing the numerical displacement profile with the displacements measured by a laser Doppler vibrometer. The comparison between the numerical and experimental results shows excellent agreement for both electrical impedance curve and for the displacement profile over the disk surface. The agreement between numerical and experimental displacement profiles shows that, although only the electrical impedance curve is considered in the adjustment procedure, the obtained material properties allow simulating the displacement amplitude accurately. Copyright © 2014 Elsevier B.V. All rights reserved.
Wan, Dong; Yuan, Shaojun; Neoh, K G; Kang, E T
2010-06-01
An environmentally benign approach to surface modification was developed to impart copper surface with enhanced resistance to corrosion, bacterial adhesion and biocorrosion. Oxidative graft polymerization of 2,2'-bithiophene from the copper surface with self-assembled 2,2'-bithiophene monolayer, and subsequent reduction of silver ions to silver nanoparticles (Ag NPs) on the surface, give rise to a homogeneous bithiophene polymer (PBT) film with densely coupled Ag NPs on the copper surface (Cu-g-PBT-Ag NP surface). The immobilized Ag NPs were found to significantly inhibit bacterial adhesion and enhance the antibacterial properties of the PBT modified copper surface. The corrosion inhibition performance of the functionalized copper substrates was evaluated by Tafel polarization curves and electrochemical impedance spectroscopy. Arising from the chemical affinity of thiols for the noble and coinage metals, the copper surface functionalized with both PBT brushes and Ag NPs also exhibits long-term stability, and is thus potentially useful for combating the combined problems of corrosion and biocorrosion in harsh marine and aquatic environments.
Directed evolution can rapidly improve the activity of chimeric assembly-line enzymes
Fischbach, Michael A.; Lai, Jonathan R.; Roche, Eric D.; Walsh, Christopher T.; Liu, David R.
2007-01-01
Nonribosomal peptides (NRPs) are produced by NRP synthetase (NRPS) enzymes that function as molecular assembly lines. The modular architecture of NRPSs suggests that a domain responsible for activating a building block could be replaced with a domain from a foreign NRPS to create a chimeric assembly line that produces a new variant of a natural NRP. However, such chimeric NRPS modules are often heavily impaired, impeding efforts to create novel NRP variants by swapping domains from different modules or organisms. Here we show that impaired chimeric NRPSs can be functionally restored by directed evolution. Using rounds of mutagenesis coupled with in vivo screens for NRP production, we rapidly isolated variants of two different chimeric NRPSs with ≈10-fold improvements in enzyme activity and product yield, including one that produces new derivatives of the potent NRP/polyketide antibiotic andrimid. Because functional restoration in these examples required only modest library sizes (103 to 104 clones) and three or fewer rounds of screening, our approach may be widely applicable even for NRPSs from genetically challenging hosts. PMID:17620609
Effect of Shock Waves on Dielectric Properties of KDP Crystal
NASA Astrophysics Data System (ADS)
Sivakumar, A.; Suresh, S.; Pradeep, J. Anto; Balachandar, S.; Martin Britto Dhas, S. A.
2018-05-01
An alternative non-destructive approach is proposed and demonstrated for modifying electrical properties of crystal using shock-waves. The method alters dielectric properties of a potassium dihydrogen phosphate (KDP) crystal by loading shock-waves generated by a table-top shock tube. The experiment involves launching the shock-waves perpendicular to the (100) plane of the crystal using a pressure driven table-top shock tube with Mach number 1.9. Electrical properties of dielectric constant, dielectric loss, permittivity, impedance, AC conductivity, DC conductivity and capacitance as a function of spectrum of frequency from 1 Hz to 1 MHz are reported for both pre- and post-shock wave loaded conditions of the KDP crystal. The experimental results reveal that dielectric constant of KDP crystal is sensitive to the shock waves such that the value decreases for the shock-loaded KDP sample from 158 to 147. The advantage of the proposed approach is that it is an alternative to the conventional doping process for tailoring dielectric properties of this type of crystal.
Electrical properties of a liquid crystal dispersed in an electrospun cellulose acetate network
Danila, Octavian; Ganea, Constantin Paul
2018-01-01
Electro-optical devices that work in a similar fashion as PDLCs (polymer-dispersed liquid crystals), produced from cellulose acetate (CA) electrospun fibers deposited onto indium tin oxide coated glass and a nematic liquid crystal (E7), were studied. CA and the CA/liquid crystal composite were characterized by multiple investigation techniques, such as polarized optical microscopy, dielectric spectroscopy and impedance measurements. Dielectric constant and electric energy loss were studied as a function of frequency and temperature. The activation energy was evaluated and the relaxation time was obtained by fitting the spectra of the dielectric loss with the Havriliak–Negami functions. To determine the electrical characteristics of the studied samples, impedance measurements results were treated using the Cole–Cole diagram and the three-element equivalent model. PMID:29441261
Electrical properties of a liquid crystal dispersed in an electrospun cellulose acetate network.
Maximean, Doina Manaila; Danila, Octavian; Almeida, Pedro L; Ganea, Constantin Paul
2018-01-01
Electro-optical devices that work in a similar fashion as PDLCs (polymer-dispersed liquid crystals), produced from cellulose acetate (CA) electrospun fibers deposited onto indium tin oxide coated glass and a nematic liquid crystal (E7), were studied. CA and the CA/liquid crystal composite were characterized by multiple investigation techniques, such as polarized optical microscopy, dielectric spectroscopy and impedance measurements. Dielectric constant and electric energy loss were studied as a function of frequency and temperature. The activation energy was evaluated and the relaxation time was obtained by fitting the spectra of the dielectric loss with the Havriliak-Negami functions. To determine the electrical characteristics of the studied samples, impedance measurements results were treated using the Cole-Cole diagram and the three-element equivalent model.
Bancalari, Elena; Bernini, Valentina; Bottari, Benedetta; Neviani, Erasmo; Gatti, Monica
2016-01-01
Impedance microbiology is a method that enables tracing microbial growth by measuring the change in the electrical conductivity. Different systems, able to perform this measurement, are available in commerce and are commonly used for food control analysis by mean of measuring a point of the impedance curve, defined "time of detection." With this work we wanted to find an objective way to interpret the metabolic significance of impedance curves and propose it as a valid approach to evaluate the potential acidifying performances of starter lactic acid bacteria to be employed in milk transformation. To do this it was firstly investigated the possibility to use the Gompertz equation to describe the data coming from the impedance curve obtained by mean of BacTrac 4300®. Lag time (λ), maximum specific M% rate (μmax), and maximum value of M% (Yend) have been calculated and, given the similarity of the impedance fitted curve to the bacterial growth curve, their meaning has been interpreted. Potential acidifying performances of eighty strains belonging to Lactobacillus helveticus, Lactobacillus delbrueckii subsp. bulgaricus, Lactococcus lactis , and Streptococcus thermophilus species have been evaluated by using the kinetics parameters, obtained from Excel add-in DMFit version 2.1. The novelty and importance of our findings, obtained by means of BacTrac 4300®, is that they can also be applied to data obtained from other devices. Moreover, the meaning of λ, μmax, and Yend that we have extrapolated from Modified Gompertz equation and discussed for lactic acid bacteria in milk, can be exploited also to other food environment or other bacteria, assuming that they can give a curve and that curve is properly fitted with Gompertz equation.
Sallah, Kankoé; Giorgi, Roch; Bengtsson, Linus; Lu, Xin; Wetter, Erik; Adrien, Paul; Rebaudet, Stanislas; Piarroux, Renaud; Gaudart, Jean
2017-11-22
Mathematical models of human mobility have demonstrated a great potential for infectious disease epidemiology in contexts of data scarcity. While the commonly used gravity model involves parameter tuning and is thus difficult to implement without reference data, the more recent radiation model based on population densities is parameter-free, but biased. In this study we introduce the new impedance model, by analogy with electricity. Previous research has compared models on the basis of a few specific available spatial patterns. In this study, we use a systematic simulation-based approach to assess the performances. Five hundred spatial patterns were generated using various area sizes and location coordinates. Model performances were evaluated based on these patterns. For simulated data, comparison measures were average root mean square error (aRMSE) and bias criteria. Modeling of the 2010 Haiti cholera epidemic with a basic susceptible-infected-recovered (SIR) framework allowed an empirical evaluation through assessing the goodness-of-fit of the observed epidemic curve. The new, parameter-free impedance model outperformed previous models on simulated data according to average aRMSE and bias criteria. The impedance model achieved better performances with heterogeneous population densities and small destination populations. As a proof of concept, the basic compartmental SIR framework was used to confirm the results obtained with the impedance model in predicting the spread of cholera in Haiti in 2010. The proposed new impedance model provides accurate estimations of human mobility, especially when the population distribution is highly heterogeneous. This model can therefore help to achieve more accurate predictions of disease spread in the context of an epidemic.
Kriščiukaitis, Algimantas; Šimoliūnienė, Renata; Macas, Andrius; Petrolis, Robertas; Drėgūnas, Kęstutis; Bakšytė, Giedrė; Pieteris, Linas; Bertašienė, Zita; Žaliūnas, Remigijus
2014-01-01
Beat-to-beat alteration in ventricles repolarization reflected by alternans of amplitude and/or shape of ECG S-T,T segment (TWA) is known as phenomena related with risk of severe arrhythmias leading to sudden cardiac death. Technical difficulties have caused limited its usage in clinical diagnostics. Possibilities to register and analyze multimodal signals reflecting heart activity inspired search for new technical solutions. First objective of this study was to test whether thoracic impedance signal and beat-to-beat heart rate reflect repolarization alternans detected as TWA. The second objective was revelation of multimodal signal features more comprehensively representing the phenomena and increasing its prognostic usefulness. ECG, and thoracic impedance signal recordings made during 24h follow-up of the patients hospitalized in acute phase of myocardial infarction were used for investigation. Signal morphology variations reflecting estimates were obtained by the principal component analysis-based method. Clinical outcomes of patients (survival and/or rehospitalization in 6 and 12 months) were compared to repolarization alternans and heart rate variability estimates. Repolarization alternans detected as TWA was also reflected in estimates of thoracic impedance signal shape and variation in beat-to-beat heart rate. All these parameters showed correlation with clinical outcomes of patients. The strongest significant correlation showed magnitude of alternans in estimates of thoracic impedance signal shape. The features of ECG, thoracic impedance signal and beat-to-beat variability of heart rate, give comprehensive estimates of repolarization alternans, which correlate, with clinical outcomes of the patients and we recommend using them to improve diagnostic reliability. Copyright © 2014 Lithuanian University of Health Sciences. Production and hosting by Elsevier Urban & Partner Sp. z o.o. All rights reserved.
Bancalari, Elena; Bernini, Valentina; Bottari, Benedetta; Neviani, Erasmo; Gatti, Monica
2016-01-01
Impedance microbiology is a method that enables tracing microbial growth by measuring the change in the electrical conductivity. Different systems, able to perform this measurement, are available in commerce and are commonly used for food control analysis by mean of measuring a point of the impedance curve, defined “time of detection.” With this work we wanted to find an objective way to interpret the metabolic significance of impedance curves and propose it as a valid approach to evaluate the potential acidifying performances of starter lactic acid bacteria to be employed in milk transformation. To do this it was firstly investigated the possibility to use the Gompertz equation to describe the data coming from the impedance curve obtained by mean of BacTrac 4300®. Lag time (λ), maximum specific M% rate (μmax), and maximum value of M% (Yend) have been calculated and, given the similarity of the impedance fitted curve to the bacterial growth curve, their meaning has been interpreted. Potential acidifying performances of eighty strains belonging to Lactobacillus helveticus, Lactobacillus delbrueckii subsp. bulgaricus, Lactococcus lactis, and Streptococcus thermophilus species have been evaluated by using the kinetics parameters, obtained from Excel add-in DMFit version 2.1. The novelty and importance of our findings, obtained by means of BacTrac 4300®, is that they can also be applied to data obtained from other devices. Moreover, the meaning of λ, μmax, and Yend that we have extrapolated from Modified Gompertz equation and discussed for lactic acid bacteria in milk, can be exploited also to other food environment or other bacteria, assuming that they can give a curve and that curve is properly fitted with Gompertz equation. PMID:27799925
Chen, Shing-Jye; Gielo-Perczak, Krystyna
2011-01-01
Arch supports commonly used to alleviate foot pain can impede the normal drop of medial longitudinal arch (MLA) thereby altering its function. The purpose of the study was to examine the effect of using arch supports on vertical ground reaction force (GRF) and center of pressure (COP) during simulated midstance while the foot was statically loaded. Ten healthy young subjects were recruited. Two dimensional (2D) analysis of the MLA was captured for both barefoot (BF) and arch support conditions before and after loading via a custom made weight loading apparatus. The foot was loaded and positioned to simulate the midstance phase of walking. Two-dimensional reflective markers demarcated the MLA and captured with the loaded foot on a force platform. The impeded MLA drop was compared between the unloaded BF, loaded BF and loaded arch support conditions. The vertical GRF, the anterior-posterior and the medial-lateral COP displacements were also measured in response to the impeded MLA by the arch supports. The arch supports impeded the MLA drop (p<0.05) and shifted the COP toward the medial side (p<0.05), specifically for the rearfoot (calcaneal segment region), but no changes were determined for the vertical GRF (p>0.05). The impedance of MLA drop by the arch support altered the pattern of the ML COP shift in the rearfoot region. The use of arch supports may not relieve painful foot conditions that are associated with excessive calcaneal eversion indicated by altering COP shifts in localized foot regions.
Omari, Taher I; Dejaeger, Eddy; Tack, Jan; Van Beckevoort, Dirk; Rommel, Nathalie
2013-06-01
Automated impedance manometry (AIM) analysis measures swallow variables defining bolus timing, pressure, contractile vigour, and bolus presence, which are combined to derive a swallow risk index (SRI) correlating with aspiration. In a heterogeneous cohort of dysphagia patients, we assessed the impact of bolus volume and viscosity on AIM variables. We studied 40 patients (average age = 46 years). Swallowing of boluses was recorded with manometry, impedance, and videofluoroscopy. AIMplot software was used to derive functional variables: peak pressure (PeakP), pressure at nadir impedance (PNadImp), time from nadir impedance to peak pressure (TNadImp-PeakP), the interval of impedance drop in the distal pharynx (flow interval, FI), upper oesophageal sphincter (UES) relaxation interval (UES RI), nadir UES pressure (Nad UESP), UES intrabolus pressure (UES IBP), and UES resistance. The SRI was derived using the formula SRI = (FI * PNadImp)/(PeakP * (TNadImp-PeakP + 1)) * 100. A total of 173 liquid, 44 semisolid, and 33 solid boluses were analysed. The SRI was elevated in relation to aspiration. PeakP increased with volume. SRI was not significantly altered by bolus volume. PNadImp, UES IBP, and UES resistance increased with viscosity. SRI was lower with increased viscosity. In patients with dysphagia, the SRI is elevated in relation to aspiration, reduced by bolus viscosity, and not affected by bolus volume. These data provide evidence that pharyngeal AIM analysis may have clinical utility for assessing deglutitive aspiration risk to liquid boluses.
Input filter compensation for switching regulators
NASA Technical Reports Server (NTRS)
Lee, F. C.; Kelkar, S. S.
1982-01-01
The problems caused by the interaction between the input filter, output filter, and the control loop are discussed. The input filter design is made more complicated because of the need to avoid performance degradation and also stay within the weight and loss limitations. Conventional input filter design techniques are then dicussed. The concept of pole zero cancellation is reviewed; this concept is the basis for an approach to control the peaking of the output impedance of the input filter and thus mitigate some of the problems caused by the input filter. The proposed approach for control of the peaking of the output impedance of the input filter is to use a feedforward loop working in conjunction with feedback loops, thus forming a total state control scheme. The design of the feedforward loop for a buck regulator is described. A possible implementation of the feedforward loop design is suggested.
Ranaldo, Nunzio; Losurdo, Giuseppe; Iannone, Andrea; Principi, Mariabeatrice; Barone, Michele; De Carne, Massimo; Ierardi, Enzo; Di Leo, Alfredo
2017-09-07
A relevant percentage of non-erosive reflux disease (NERD) is refractory to proton pump inhibitors (PPIs) treatment. Multichannel intraluminal impedance pH (MII-pH) monitoring should give useful pathophysiological information about refractoriness. Therefore, our aim was to assess whether this technique could be useful to guide a 'tailored' therapy in refractory NERD. We retrospectively recruited NERD patients undergoing MII-pH monitoring for unsuccessful treatment. All patients had undergone upper endoscopy, and those with erosive esophagitis were excluded. No patient received PPI during MII-pH monitoring. Subjects were subgrouped into three categories: acid reflux, non-acid reflux and functional heartburn. MII-pH-guided therapy was performed for 4 weeks as follows: patients with acid reflux received PPI at double dose, patients with non-acid reflux PPI at full dose plus alginate four times a day and patients with functional heartburn levosulpiride 75 mg per day. A visual analog scale (VAS) ranging from 0 to 100 mm was administered before and after such tailored therapy to evaluate overall symptoms. Responders were defined by VAS improvement of at least 40%. Sixty-nine patients with refractory NERD were selected (female-male ratio 43 : 26, mean age 47.6±15.2 years). Overall effectiveness of tailored therapy was 84% without statistical difference among subgroups (88.5% acid reflux, 92% non-acid reflux, 66.6% functional heartburn; P=0.06). Univariate analysis showed that therapy failure directly correlated with functional heartburn diagnosis (OR=4.60) and suggested a trend toward a negative correlation with smoking and a positive one with nausea. However, at multivariate analysis, these parameters were not significant. Functional heartburn experienced a lower median percent VAS reduction than acid reflux (52.5% versus 66.6%, P<0.01) even if equal to non-acid reflux (66.6%). In conclusion, a tailored approach to refractory NERD, guided by MII-pH monitoring, demonstrated to be effective and should be promising to cure symptom persistence after conventional therapy failure. Nevertheless, standardized guidelines are advisable.
Fault detection techniques for complex cable shield topologies
NASA Astrophysics Data System (ADS)
Coonrod, Kurt H.; Davis, Stuart L.; McLemore, Donald P.
1994-09-01
This document presents the results of a basic principles study which investigated technical approaches for developing fault detection techniques for use on cables with complex shielding topologies. The study was limited to those approaches which could realistically be implemented on a fielded cable, i.e., approaches which would require partial disassembly of a cable were not pursued. The general approach used was to start with present transfer impedance measurement techniques and modify their use to achieve the best possible measurement range. An alternative test approach, similar to a sniffer type test, was also investigated.
Meeting the Mixed Methods Challenge of Integration in a Sociological Study of Structure and Agency
ERIC Educational Resources Information Center
Woolley, Claire M.
2009-01-01
Substantial integration of quantitative and qualitative data and findings in mixed methods studies is seldom seen, although maximizing the potential of the approach depends on this. An absence of exemplars has been identified as among a number of factors that currently impede integration in studies carried out by researchers using the approach.…
ERIC Educational Resources Information Center
Chan, Shirley
2013-01-01
The phenomenon of globalization has a significant impact on higher education, but the lack of a clear roadmap for how senior university officials should create and implement global engagement strategies and for how these approaches support (or impede) an organizational culture that fosters globalization remains a gap in knowledge in higher…
Solid-Binding Peptides in Biomedicine.
Care, Andrew; Bergquist, Peter L; Sunna, Anwar
2017-01-01
Some peptides are able to bind to inorganic materials such as silica and gold. Over the past decade, Solid-binding peptides (SBPs) have been used increasingly as molecular building blocks in nanobiotechnology. These peptides show selectivity and bind with high affinity to a diverse range of inorganic surfaces e.g. metals, metal oxides, metal compounds, magnetic materials, semiconductors, carbon materials, polymers and minerals. They can be used in applications such as protein purification and synthesis, assembly and the functionalization of nanomaterials. They offer simple and versatile bioconjugation methods that can increase biocompatibility and also direct the immobilization and orientation of nanoscale entities onto solid supports without impeding their functionality. SBPs have been employed in numerous nanobiotechnological applications such as the controlled synthesis of nanomaterials and nanostructures, formation of hybrid biomaterials, immobilization of functional proteins and improved nanomaterial biocompatibility. With advances in nanotechnology, a multitude of novel nanomaterials have been designed and synthesized for diagnostic and therapeutic applications. New approaches have been developed recently to exert a greater control over bioconjugation and eventually, over the optimal and functional display of biomolecules on the surfaces of many types of solid materials. In this chapter we describe SBPs and highlight some selected examples of their potential applications in biomedicine.
Kim, Raeyoung; Nam, Yoonkey
2015-04-01
Platinum black (PtBK) has long been used for microelectrode fabrication owing to its high recording performance of neural signals. The porous structure of PtBK enlarges the surface area and lowers the impedance, which results in background noise reduction. However, the brittleness of PtBK has been a problem in practice. In this work, we report mechanically stable PtBK microelectrodes using a bioinspired adhesive film, polydopamine (pDA), while maintaining the low impedance of PtBK. The pDA layer was incorporated into the PtBK structure through electrochemical layer-by-layer deposition. Varying the number of layers and the order of materials, multi-layered pDA-PtBK hybrids were fabricated and the electrical properties, both impedance and charge injection limit, were evaluated. Multilayered pDA-PtBK hybrids had electrical impedances as low as PtBK controls and charge injection limit twice larger than controls. For the 30 min-ultrasonication agitation test, impedance levels rarely changed for some of the pDA-PtBK hybrids indicating that the pDA improved the mechanical property of the PtBK structures. The pDA-PtBK hybrid microelectrodes readily recorded neural signals of cultured hippocampal neurons, where background noise levels and signal-to-noise were 2.43 ∼ 3.23 μVrms and 28.4 ∼ 69.1, respectively. The developed pDA-PtBK hybrid microelectrodes are expected to be applicable to neural sensors for neural prosthetic studies.
Effects of social cognitive impairment on speech disorder in schizophrenia.
Docherty, Nancy M; McCleery, Amanda; Divilbiss, Marielle; Schumann, Emily B; Moe, Aubrey; Shakeel, Mohammed K
2013-05-01
Disordered speech in schizophrenia impairs social functioning because it impedes communication with others. Treatment approaches targeting this symptom have been limited by an incomplete understanding of its causes. This study examined the process underpinnings of speech disorder, assessed in terms of communication failure. Contributions of impairments in 2 social cognitive abilities, emotion perception and theory of mind (ToM), to speech disorder were assessed in 63 patients with schizophrenia or schizoaffective disorder and 21 nonpsychiatric participants, after controlling for the effects of verbal intelligence and impairments in basic language-related neurocognitive abilities. After removal of the effects of the neurocognitive variables, impairments in emotion perception and ToM each explained additional variance in speech disorder in the patients but not the controls. The neurocognitive and social cognitive variables, taken together, explained 51% of the variance in speech disorder in the patients. Schizophrenic disordered speech may be less a concomitant of "positive" psychotic process than of illness-related limitations in neurocognitive and social cognitive functioning.
NASA Astrophysics Data System (ADS)
Qiu, Hanxun; Han, Xuebin; Qiu, Feilong; Yang, Junhe
2016-07-01
A polyaniline/graphene composite with covalently-bond is synthesized by a novel approach. In this way, graphene oxide is functionalized firstly by introducing amine groups onto the surface with the reduction of graphene oxide in the process and then served as the anchor sites for the growth of polyaniline (PANI) via in-situ polymerization. The composite material is characterized by electron microscopy, the resonant Raman spectra, X-ray diffraction, transform infrared spectroscopy and X-ray photoelectron spectroscopy. The electrochemical properties of the composite are measured by cyclic voltammetry, electrochemical impedance spectroscopy and galvanostatic charging/discharging. With the functionalization process, the graphene/polyaniline composite electrode exhibits remarkably enhanced electrochemical performance with specific capacitance of 489 F g-1 at 0.5 A g-1, which is superior to those of its individual components. The outstanding electrochemical performance of the hybrid can be attributed to its covalently synergistic effect between graphene and polyaniline, suggesting promising potentials for supercapacitors.
New perspectives on neuronal development via microfluidic environments
Millet, Larry J.; Gillette, Martha U.
2012-01-01
Understanding the signals that guide neuronal development and direct formation of axons, dendrites, and synapses during wiring of the brain is a fundamental challenge of developmental neuroscience. Discovering how local signals shape developing neurons has been impeded by the inability of conventional culture methods to interrogate micro-environments of complex neuronal cytoarchitectures, where different sub-domains encounter distinct chemical, physical, and fluidic features. Micro-fabrication techniques are enabling the creation of micro-environments tailored to neuronal structures and sub-domains, with unprecedented access and control. The design, fabrication, and properties of microfluidic devices offer significant advantages for addressing unresolved issues of neuronal development. These high-resolution approaches are poised to contribute new insights into mechanisms for restoring neuronal function and connectivity compromised by injury, stress, and neurodegeneration. PMID:23031246
A Cryogenic Waveguide Mount for Microstrip Circuit and Material Characterization
NASA Technical Reports Server (NTRS)
U-yen, Kongpop; Brown, Ari D.; Moseley, Samuel H.; Noroozian, Omid; Wollack, Edward J.
2016-01-01
A waveguide split-block fixture used in the characterization of thin-film superconducting planar circuitry at millimeter wavelengths is described in detail. The test fixture is realized from a pair of mode converters, which transition from rectangular-waveguide to on-chip microstrip-line signal propagation via a stepped ridge-guide impedance transformer. The observed performance of the W-band package at 4.2K has a maximum in-band transmission ripple of 2dB between 1.53 and 1.89 times the waveguide cutoff frequency. This metrology approach enables the characterization of superconducting microstrip test structures as a function temperature and frequency. The limitations of the method are discussed and representative data for superconducting Nb and NbTiN thin film microstrip resonators on single-crystal Si dielectric substrates are presented.
A Unique Instrumental Malfunction during Robotic Prostatectomy
Park, Sung Yul; Ahn, Jenny Jin-Kyung; Jeong, Wooju; Ham, Won Sik
2010-01-01
Over the past decade, the introduction of robotics in the field of medicine has provided a new approach to patients requiring surgery, and both its advantages and disadvantages are currently under study by many groups worldwide. The use of robotics has especially been considered by the urological community as a treatment option in radical prostatectomy. The current case report is one in which the da Vinci Surgical System™, with fourth arm use was employed in radical prostatectomy. This case presents a unique occurrence in which a bolt of the Prograsper forcep became loose during an operation, leading to diminished device functionality and later impedance of its removal. A circumstance such as this has not previously been reported, so we introduce for other robotic surgeons our unique instrumental malfunction case during a robotic prostatectomy. PMID:20046531
Panzacchi, Manuela; Van Moorter, Bram; Strand, Olav; Saerens, Marco; Kivimäki, Ilkka; St Clair, Colleen C; Herfindal, Ivar; Boitani, Luigi
2016-01-01
The loss, fragmentation and degradation of habitat everywhere on Earth prompts increasing attention to identifying landscape features that support animal movement (corridors) or impedes it (barriers). Most algorithms used to predict corridors assume that animals move through preferred habitat either optimally (e.g. least cost path) or as random walkers (e.g. current models), but neither extreme is realistic. We propose that corridors and barriers are two sides of the same coin and that animals experience landscapes as spatiotemporally dynamic corridor-barrier continua connecting (separating) functional areas where individuals fulfil specific ecological processes. Based on this conceptual framework, we propose a novel methodological approach that uses high-resolution individual-based movement data to predict corridor-barrier continua with increased realism. Our approach consists of two innovations. First, we use step selection functions (SSF) to predict friction maps quantifying corridor-barrier continua for tactical steps between consecutive locations. Secondly, we introduce to movement ecology the randomized shortest path algorithm (RSP) which operates on friction maps to predict the corridor-barrier continuum for strategic movements between functional areas. By modulating the parameter Ѳ, which controls the trade-off between exploration and optimal exploitation of the environment, RSP bridges the gap between algorithms assuming optimal movements (when Ѳ approaches infinity, RSP is equivalent to LCP) or random walk (when Ѳ → 0, RSP → current models). Using this approach, we identify migration corridors for GPS-monitored wild reindeer (Rangifer t. tarandus) in Norway. We demonstrate that reindeer movement is best predicted by an intermediate value of Ѳ, indicative of a movement trade-off between optimization and exploration. Model calibration allows identification of a corridor-barrier continuum that closely fits empirical data and demonstrates that RSP outperforms models that assume either optimality or random walk. The proposed approach models the multiscale cognitive maps by which animals likely navigate real landscapes and generalizes the most common algorithms for identifying corridors. Because suboptimal, but non-random, movement strategies are likely widespread, our approach has the potential to predict more realistic corridor-barrier continua for a wide range of species. © 2015 The Authors. Journal of Animal Ecology © 2015 British Ecological Society.
Electrical impedance tomography
Lobo, Beatriz; Hermosa, Cecilia; Abella, Ana
2018-01-01
Continuous assessment of respiratory status is one of the cornerstones of modern intensive care unit (ICU) monitoring systems. Electrical impedance tomography (EIT), although with some constraints, may play the lead as a new diagnostic and guiding tool for an adequate optimization of mechanical ventilation in critically ill patients. EIT may assist in defining mechanical ventilation settings, assess distribution of tidal volume and of end-expiratory lung volume (EELV) and contribute to titrate positive end-expiratory pressure (PEEP)/tidal volume combinations. It may also quantify gains (recruitment) and losses (overdistention or derecruitment), granting a more realistic evaluation of different ventilator modes or recruitment maneuvers, and helping in the identification of responders and non-responders to such maneuvers. Moreover, EIT also contributes to the management of life-threatening lung diseases such as pneumothorax, and aids in guiding fluid management in the critical care setting. Lastly, assessment of cardiac function and lung perfusion through electrical impedance is on the way. PMID:29430443
Development of an Inductively Coupled Thermometer for a Cryogenic Half-Wave Plate
NASA Astrophysics Data System (ADS)
Madurowicz, Alexander; Kusaka, Akito
2017-01-01
The current state of Cosmic Microwave Background (CMB) research has focused much attention on the measurement of polarization. In an effort to modulate the CMB polarization while also minimizing photon noise due to thermal emission, we are developing a sapphire half-wave plate (HWP) cooled to 50 K rotating at 2 Hz on a superconducting magnetic levitating bearing. In order to measure the temperature of the rotor without making physical contact, we designed an inductively coupled cryogenic thermometer. The complex impedance of the circuit has a resonant peak when driven around 1 MHz. The width of this resonance is dependent on the value of the resistor, which varies with temperature and functions as a thermometer once calibrated. In this talk, we will present results from stationary measurements of this impedance and discuss the temperature accuracy of this thermometer, as well as a preliminary circuit design to measure this impedance during the HWP rotation.
The acoustic field of a point source in a uniform boundary layer over an impedance plane
NASA Technical Reports Server (NTRS)
Zorumski, W. E.; Willshire, W. L., Jr.
1986-01-01
The acoustic field of a point source in a boundary layer above an impedance plane is investigated anatytically using Obukhov quasi-potential functions, extending the normal-mode theory of Chunchuzov (1984) to account for the effects of finite ground-plane impedance and source height. The solution is found to be asymptotic to the surface-wave term studies by Wenzel (1974) in the limit of vanishing wind speed, suggesting that normal-mode theory can be used to model the effects of an atmospheric boundary layer on infrasonic sound radiation. Model predictions are derived for noise-generation data obtained by Willshire (1985) at the Medicine Bow wind-turbine facility. Long-range downwind propagation is found to behave as a cylindrical wave, with attention proportional to the wind speed, the boundary-layer displacement thickness, the real part of the ground admittance, and the square of the frequency.
NASA Astrophysics Data System (ADS)
Kumar, Mukesh; Ojha, A.; Garg, A. D.; Puntambekar, T. A.; Senecha, V. K.
2017-02-01
According to the quasi electrostatic model of linear response capacitive beam position monitor (BPM), the position sensitivity of the device depends only on the aperture of the device and it is independent of processing frequency and load impedance. In practice, however, due to the inter-electrode capacitive coupling (cross talk), the actual position sensitivity of the device decreases with increasing frequency and load impedance. We have taken into account the inter-electrode capacitance to derive and propose a new analytical expression for the position sensitivity as a function of frequency and load impedance. The sensitivity of a linear response shoe-box type BPM has been obtained through simulation using CST Studio Suite to verify and confirm the validity of the new analytical equation. Good agreement between the simulation results and the new analytical expression suggest that this method can be exploited for proper designing of BPM.
Resistivity and phase in localized BIA
NASA Astrophysics Data System (ADS)
Shiffman, C. A.; Aaron, R.; Amoss, V.; Therrien, J.; Coomler, K.
1999-10-01
We describe a system for highly reproducible non-invasive rf impedance measurements as a function of position along body segments such as the thigh. Results are reported for mainly healthy male and female subjects ranging in age from 19 to 65 and in body-mass index from 15 to 40. A principal conclusion is that the phase of the impedance falls monotonically with increasing distance from the knee, with average values substantially above what is found using standard, whole-body bioelectrical impedance analysis (BIA). To compensate for thigh shape, the data are further analysed using an anatomical model based on reasonable approximations for the distributions of muscle, fat and bone, yielding values of the effective resistivity for current flow parallel to the muscle fibres. The phase and resistivity results are discussed with reference to the whole-body BIA study of maintenance haemodialysis patients by Chertow et al, and in regard to possible physiological correlations observed in this work.
Method of detecting system function by measuring frequency response
NASA Technical Reports Server (NTRS)
Morrison, John L. (Inventor); Morrison, William H. (Inventor); Christophersen, Jon P. (Inventor)
2012-01-01
Real-time battery impedance spectrum is acquired using a one-time record. Fast Summation Transformation (FST) is a parallel method of acquiring a real-time battery impedance spectrum using a one-time record that enables battery diagnostics. An excitation current to a battery is a sum of equal amplitude sine waves of frequencies that are octave harmonics spread over a range of interest. A sample frequency is also octave and harmonically related to all frequencies in the sum. The time profile of this signal has a duration that is a few periods of the lowest frequency. The voltage response of the battery, average deleted, is the impedance of the battery in the time domain. Since the excitation frequencies are known and octave and harmonically related, a simple algorithm, FST, processes the time record by rectifying relative to the sine and cosine of each frequency. Another algorithm yields real and imaginary components for each frequency.
Method of detecting system function by measuring frequency response
Morrison, John L [Butte, MT; Morrison, William H [Manchester, CT; Christophersen, Jon P [Idaho Falls, ID
2012-04-03
Real-time battery impedance spectrum is acquired using a one-time record. Fast Summation Transformation (FST) is a parallel method of acquiring a real-time battery impedance spectrum using a one-time record that enables battery diagnostics. An excitation current to a battery is a sum of equal amplitude sine waves of frequencies that are octave harmonics spread over a range of interest. A sample frequency is also octave and harmonically related to all frequencies in the sum. The time profile of this signal has a duration that is a few periods of the lowest frequency. The voltage response of the battery, average deleted, is the impedance of the battery in the time domain. Since the excitation frequencies are known and octave and harmonically related, a simple algorithm, FST, processes the time record by rectifying relative to the sine and cosine of each frequency. Another algorithm yields real and imaginary components for each frequency.
Adaptive microwave impedance memory effect in a ferromagnetic insulator.
Lee, Hanju; Friedman, Barry; Lee, Kiejin
2016-12-14
Adaptive electronics, which are often referred to as memristive systems as they often rely on a memristor (memory resistor), are an emerging technology inspired by adaptive biological systems. Dissipative systems may provide a proper platform to implement an adaptive system due to its inherent adaptive property that parameters describing the system are optimized to maximize the entropy production for a given environment. Here, we report that a non-volatile and reversible adaptive microwave impedance memory device can be realized through the adaptive property of the dissipative structure of the driven ferromagnetic system. Like the memristive device, the microwave impedance of the device is modulated as a function of excitation microwave passing through the device. This kind of new device may not only helpful to implement adaptive information processing technologies, but also may be useful to investigate and understand the underlying mechanism of spontaneous formation of complex and ordered structures.
Millimeter-wave integrated-horn antennas. I - Theory. II - Experiment
NASA Technical Reports Server (NTRS)
Eleftheriades, George V.; Ali-Ahmad, Walid Y.; Katehi, Linda P. B.; Rebeiz, Gabriel M.
1991-01-01
Full-wave analysis is employed to determine the far-field pattern and input impedance of a dipole-fed horn antenna in a ground plane, and the theoretical results are compared with mm-wave and microwave data. The theoretical work exploits the Green's function corresponding to the horn structure and the method of moments. It is determined that the horn should have 70 sections/wavelength and 50 secondary modes for optimized accuracy, and certain dipole positions can reduce the resonance to zero. The experimentally derived impedance and radiation patterns agree with the constraints developed theoretically. The 70-degree flare-angle horn with selected dipole positions and horn apertures yields good radiation patterns, cross-polarization levels, and resonant dipole impedances. The conclusions are of interest to the development of the horn antennas etched in Si/GaAs for applications to zero-visibility tracking, radio astronomy, plasma diagnostics, and remote sensing.
Adaptive microwave impedance memory effect in a ferromagnetic insulator
Lee, Hanju; Friedman, Barry; Lee, Kiejin
2016-01-01
Adaptive electronics, which are often referred to as memristive systems as they often rely on a memristor (memory resistor), are an emerging technology inspired by adaptive biological systems. Dissipative systems may provide a proper platform to implement an adaptive system due to its inherent adaptive property that parameters describing the system are optimized to maximize the entropy production for a given environment. Here, we report that a non-volatile and reversible adaptive microwave impedance memory device can be realized through the adaptive property of the dissipative structure of the driven ferromagnetic system. Like the memristive device, the microwave impedance of the device is modulated as a function of excitation microwave passing through the device. This kind of new device may not only helpful to implement adaptive information processing technologies, but also may be useful to investigate and understand the underlying mechanism of spontaneous formation of complex and ordered structures. PMID:27966536
Method of detecting system function by measuring frequency response
Morrison, John L.; Morrison, William H.; Christophersen, Jon P.; Motloch, Chester G.
2013-01-08
Methods of rapidly measuring an impedance spectrum of an energy storage device in-situ over a limited number of logarithmically distributed frequencies are described. An energy storage device is excited with a known input signal, and a response is measured to ascertain the impedance spectrum. An excitation signal is a limited time duration sum-of-sines consisting of a select number of frequencies. In one embodiment, magnitude and phase of each frequency of interest within the sum-of-sines is identified when the selected frequencies and sample rate are logarithmic integer steps greater than two. This technique requires a measurement with a duration of one period of the lowest frequency. In another embodiment, where selected frequencies are distributed in octave steps, the impedance spectrum can be determined using a captured time record that is reduced to a half-period of the lowest frequency.
Saffar, Saber; Abdullah, Amir
2012-01-01
The effective ultrasonic energy radiation into the air of piezoelectric transducers requires using multilayer matching systems with accurately selected acoustic impedances and the thickness of particular layers. One major problem of ultrasonic transducers, radiating acoustic energy into air, is to find the proper acoustic impedances of one or more matching layers. This work aims at developing an original solution to the acoustic impedance mismatch between transducer and air. If the acoustic impedance defences between transducer and air be more, then finding best matching layer(s) is harder. Therefore we consider PZT (lead zirconate titanate piezo electric) transducer and air that has huge acoustic impedance deference. The vibration source energy (PZT), which is used to generate the incident wave, consumes a part of the mechanical energy and converts it to an electrical one in theoretical calculation. After calculating matching layers, we consider the energy source as layer to design a transducer. However, this part of the mechanical energy will be neglected during the mathematical work. This approximation is correct only if the transducer is open-circuit. Since the possibilities of choosing material with required acoustic impedance are limited (the counted values cannot always be realized and applied in practice) it is necessary to correct the differences between theoretical values and the possibilities of practical application of given acoustic impedances. Such a correction can be done by manipulating other parameters of matching layers (e.g. by changing their thickness). The efficiency of the energy transmission from the piezoceramic transducer through different layers with different thickness and different attenuation enabling a compensation of non-ideal real values by changing their thickness was computer analyzed (base on genetic algorithm). Firstly, three theoretical solutions were investigated. Namely, Chebyshev, Desilets and Souquet theories. However, the obtained acoustic impedances do not necessarily correspond to a nowadays available material. Consequently, the values of the acoustic impedances are switched to the nearest values in a large material database. The switched values of the acoustic impedances do not generally give efficient transmission coefficients. Therefore, we proposed, in a second step, the use of a genetic algorithm (GA) to select the best acoustic impedances for matching layers from the material database for a narrow band ultrasonic transducer that work at frequency below the 2.5MHz by considering attenuation. However this bank is rich, the results get better. So the accuracy of the propose method increase by using a lot of materials with exact data for acoustic impedance and their attenuation, especially in high frequency. This yields highly more efficient transmission coefficient. In fact by using increasing number of layer we can increase our chance to find the best sets of materials with valuable both in acoustic impedance and low attenuation. Precisely, the transmission coefficient is almost equal to unity for the all studied cases. Finally the effect of thickness on transmission coefficient is investigated for different layers. The results showed that the transmission coefficient for air media is a function of thickness and sensitive to it even for small variation in thickness. In fact, the sensitivity increases when the differences of acoustic impedances to be high (difference between PZT and air). Copyright © 2011 Elsevier B.V. All rights reserved.
Modeling of electrical capacitance tomography with the use of complete electrode model
NASA Astrophysics Data System (ADS)
Fang, Weifu
2016-10-01
We introduce the complete electrode model in the modeling of electrical capacitance tomography (ECT), which extends the model with the commonly used model for electrodes. We show that the solution of the complete electrode model approaches the solution of the corresponding common electrode model as the impedance effect on the electrodes vanishes. We also derive the nonlinear relation between capacitance and permitivity and the sensitivity maps with respect to both the permittivity and the impedance constants, and present a finite difference scheme in polar coordinates for the case of circular ECT sensors that retains the continuity of displacement current with piecewise-constant permitivities.
Evaluation of an Impedance Threshold Device as a VIIP Countermeasure
NASA Technical Reports Server (NTRS)
Ebert, Douglas; Macias, Brandon; Sargsyan, Ashot; Garcia, Kathleen; Stenger, Michael; Hargens, Alan; Johnston, Smith; Kemp, David; Danielson, Richard
2017-01-01
Visual Impairment/Intracranial Pressure (VIIP) is a top human spaceflight risk for which NASA does not currently have a proven mitigation strategy. Thigh cuffs and lower body negative pressure (LBNP) devices have been or are currently being evaluated as a means to reduce VIIP signs and symptoms, but these methods alone may not provide sufficient relief of cephalic venous congestion and VIIP symptoms. Additionally, current LBNP devices are too large and cumbersome for their systematic use as a countermeasure. Therefore, a novel approach is needed that is easy to implement and provides specific relief of symptoms. This investigation will evaluate an impedance threshold device (ITD) as a VIIP countermeasure.
Electrical Impedance Tomography: a new study method for neonatal Respiratory Distress Syndrome?
Chatziioannidis, I; Samaras, T; Nikolaidis, N
2011-01-01
Treatment of cardiorespiratory system diseases is a procedure that usually demands data collection on terms of the anatomy and the operation of the organs that are under study. Electrical Impedance Tomography (EIT) is an alternative approach, in comparison to existing techniques. With EIT electrodes are placed in the perimeter of the human body and images of the estimated organ are reconstructed, using the measurement of its impendence (or resistance) distribution and determining its alteration through time, while at the same time the patient is not exposed to ionizing radiation. Its clinical use presupposes the correct placement of the electrodes over the perimeter of the human body, the rapid data collection and electrical safety. It is a low cost technique and it is implemented near the patient. It is able to determine the distribution of ventilation, blood supply, diffused or localized lung defects, but it can also estimate therapeutic interventions or alteration to assisted ventilation of the neonate. EIT was developed at the beginning of the 1980s, but it has only recently begun to be implemented on neonates, and especially in the study of their respiratory system function. The low rate of image analysis is considered to be a drawback, but it is offset by the potential offered for the estimation of lungs' function (both under normal and pathological conditions), since ventilation and resistance are two quite similar concepts. In this review the most important studies about EIT are mentioned as a method of estimating respiratory distress syndrome in neonates. In terms of the above mentioned development, it is supposed that this technique will offer a great amount of help to the doctor in his / her estimations of the cardiorespiratory system and to his / her selection of the best intervening strategies. PMID:22435017
Frerichs, Inéz; Amato, Marcelo B P; van Kaam, Anton H; Tingay, David G; Zhao, Zhanqi; Grychtol, Bartłomiej; Bodenstein, Marc; Gagnon, Hervé; Böhm, Stephan H; Teschner, Eckhard; Stenqvist, Ola; Mauri, Tommaso; Torsani, Vinicius; Camporota, Luigi; Schibler, Andreas; Wolf, Gerhard K; Gommers, Diederik; Leonhardt, Steffen; Adler, Andy
2017-01-01
Electrical impedance tomography (EIT) has undergone 30 years of development. Functional chest examinations with this technology are considered clinically relevant, especially for monitoring regional lung ventilation in mechanically ventilated patients and for regional pulmonary function testing in patients with chronic lung diseases. As EIT becomes an established medical technology, it requires consensus examination, nomenclature, data analysis and interpretation schemes. Such consensus is needed to compare, understand and reproduce study findings from and among different research groups, to enable large clinical trials and, ultimately, routine clinical use. Recommendations of how EIT findings can be applied to generate diagnoses and impact clinical decision-making and therapy planning are required. This consensus paper was prepared by an international working group, collaborating on the clinical promotion of EIT called TRanslational EIT developmeNt stuDy group. It addresses the stated needs by providing (1) a new classification of core processes involved in chest EIT examinations and data analysis, (2) focus on clinical applications with structured reviews and outlooks (separately for adult and neonatal/paediatric patients), (3) a structured framework to categorise and understand the relationships among analysis approaches and their clinical roles, (4) consensus, unified terminology with clinical user-friendly definitions and explanations, (5) a review of all major work in thoracic EIT and (6) recommendations for future development (193 pages of online supplements systematically linked with the chief sections of the main document). We expect this information to be useful for clinicians and researchers working with EIT, as well as for industry producers of this technology. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Nguyen, N Q; Holloway, R H; Smout, A J; Omari, T I
2013-03-01
Automated integrated analysis of impedance and pressure signals has been reported to identify patients at risk of developing dysphagia post fundoplication. This study aimed to investigate this analysis in the evaluation of patients with non-obstructive dysphagia (NOD) and normal manometry (NOD/NM). Combined impedance-manometry was performed in 42 patients (27F : 15M; 56.2 ± 5.1 years) and compared with that of 24 healthy subjects (8F : 16M; 48.2 ± 2.9 years). Both liquid and viscous boluses were tested. MATLAB-based algorithms defined the median intrabolus pressure (IBP), IBP slope, peak pressure (PP), and timing of bolus flow relative to peak pressure (TNadImp-PP). An index of pressure and flow (PFI) in the distal esophagus was derived from these variables. Diagnoses based on conventional manometric assessment: diffuse spasm (n = 5), non-specific motor disorders (n = 19), and normal (n = 11). Patients with achalasia (n = 7) were excluded from automated impedance-manometry (AIM) analysis. Only 2/11 (18%) patients with NOD/NM had evidence of flow abnormality on conventional impedance analysis. Several variables derived by integrated impedance-pressure analysis were significantly different in patients as compared with healthy: higher PNadImp (P < 0.01), IBP (P < 0.01) and IBP slope (P < 0.05), and shorter TNadImp_PP (P = 0.01). The PFI of NOD/NM patients was significantly higher than that in healthy (liquid: 6.7 vs 1.2, P = 0.02; viscous: 27.1 vs 5.7, P < 0.001) and 9/11 NOD/NM patients had abnormal PFI. Overall, the addition of AIM analysis provided diagnoses and/or a plausible explanation in 95% (40/42) of patients who presented with NOD. Compared with conventional pressure-impedance assessment, integrated analysis is more sensitive in detecting subtle abnormalities in esophageal function in patients with NOD and normal manometry. © 2012 Blackwell Publishing Ltd.
Real-Time Cytotoxicity Assay for Rapid and Sensitive Detection of Ricin from Complex Matrices
Pauly, Diana; Worbs, Sylvia; Kirchner, Sebastian; Shatohina, Olena; Dorner, Martin B.; Dorner, Brigitte G.
2012-01-01
Background In the context of a potential bioterrorist attack sensitive and fast detection of functionally active toxins such as ricin from complex matrices is necessary to be able to start timely countermeasures. One of the functional detection methods currently available for ricin is the endpoint cytotoxicity assay, which suffers from a number of technical deficits. Methodology/Findings This work describes a novel online cytotoxicity assay for the detection of active ricin and Ricinus communis agglutinin, that is based on a real-time cell electronic sensing system and impedance measurement. Characteristic growth parameters of Vero cells were monitored online and used as standardized viability control. Upon incubation with toxin the cell status and the cytotoxic effect were visualized using a characteristic cell index–time profile. For ricin, tested in concentrations of 0.06 ng/mL or above, a concentration-dependent decrease of cell index correlating with cytotoxicity was recorded between 3.5 h and 60 h. For ricin, sensitive detection was determined after 24 h, with an IC50 of 0.4 ng/mL (for agglutinin, an IC50 of 30 ng/mL was observed). Using functionally blocking antibodies, the specificity for ricin and agglutinin was shown. For detection from complex matrices, ricin was spiked into several food matrices, and an IC50 ranging from 5.6 to 200 ng/mL was observed. Additionally, the assay proved to be useful in detecting active ricin in environmental sample materials, as shown for organic fertilizer containing R. communis material. Conclusions/Significance The cell-electrode impedance measurement provides a sensitive online detection method for biologically active cytotoxins such as ricin. As the cell status is monitored online, the assay can be standardized more efficiently than previous approaches based on endpoint measurement. More importantly, the real-time cytotoxicity assay provides a fast and easy tool to detect active ricin in complex sample matrices. PMID:22532852
Smith, S; Madden, A M
2016-12-01
The accurate and valid assessment of body composition is essential for the diagnostic evaluation of nutritional status, identifying relevant outcome measures, and determining the effectiveness of current and future nutritional interventions. Developments in technology and our understanding of the influences of body composition on risk and outcome will provide practitioners with new opportunities to enhance current practice and to lead future improvements in practice. This is the second of a two-part narrative review that aims to critically evaluate body composition methodology in diverse adult populations, with a primary focus on its use in the assessment and monitoring of under-nutrition. Part one focused on anthropometric variables [Madden and Smith (2016) J Hum Nutr Diet 29: 7-25] and part two focuses on the use of imaging techniques, bioelectrical impedance analysis, markers of muscle strength and functional status, with particular reference to developments relevant to practice. © 2016 The British Dietetic Association Ltd.
2012-07-19
calculation point (z’, w) gives the size of the smallest cubature that provides w SD at the point z’ Figure F.1. The graph of the function f in (F.9...77 Figure F.2. The graph of the function g in (F.10...77 Figure F.3. The graph of the function h in (F.13
Rommel, Nathalie; Omari, Taher I; Selleslagh, Margot; Kritas, Stamatiki; Cock, Charles; Rosan, Rachel; Rodriguez, Leonel; Nurko, Samuel
2015-12-01
Pressure-flow analysis allows assessing esophageal bolus transport in relation to esophageal pressures. This study aimed to characterize pressure-flow metrics in relation to dysphagia in paediatric patients. We analysed esophageal pressure-impedance recordings of 5 ml liquid and viscous swallows from 35 children (17 M, mean 10.5 ± 0.8 years). Primary indication for referral was gastroesophageal reflux disease (GERD) (9), post-fundoplication dysphagia (5), idiopathic dysphagia (16), trachea-esophageal fistula (2) and other (3). Peristaltic function was assessed using the 20 mmHg iso-contour defect and the timing between bolus pressure and flow was assessed using the Pressure Flow Index, a metric elevated in relation to dysphagia. Patients were stratified in relation to dysphagia and to peristaltic defect size. Dysphagia was characterized by a weaker peristalsis for liquids and higher Pressure Flow Index for viscous. When patients were stratified based on weak or normal peristalsis, dysphagia with weak peristalsis related to a larger iso-contour defect size and dysphagia with normal peristalsis related to higher Pressure Flow Index. Pressure-flow analysis enables differentiation of patients with dysphagia due to weak peristalsis (poor bolus clearance) from abnormal bolus flow resistance (esophageal outflow obstruction). This new dichotomous categorization of esophageal function may help guide the selection of optimal treatment such as pharmacological or endoscopic therapy. • Pressure-flow analysis (PFA) can detect abnormalities in esophageal motility using integrated analysis of bolus propulsion and bolus flow during swallowing. • AIM analysis has recently been reported to be useful in identifying subtle pre-operative esophageal dysfunction in adult patients who developed post-fundoplication dysphagia as well as in patients with non-obstructive dysphagia. • Pressure-flow parameters can distinguish the cause of dysphagia in paediatric patients. • Combined high-resolution manometry and impedance measurements with pressure-flow analysis can differentiate paediatric patients with dysphagia symptoms in relation to either weak peristalsis (poor bolus clearance) or over-pressurization (abnormal bolus flow resistance). HOW MIGHT IT IMPACT ON CLINICAL PRACTICE IN THE FUTURE? • This study supports the use of a novel objective analysis method on recordings that are readily used in paediatric clinical practice. • The pressure-flow approach allows discriminating esophageal dysfunction in relation to dysphagia symptoms in children. This has not been achieved in children with current analysis methods. • The new findings of this study allow a dichotomous categorization of esophageal function, which may help to guide the selection of the most optimal treatment such as pharmacological or endoscopic therapy.
NASA Astrophysics Data System (ADS)
Dadami, Sunanda T.; Matteppanvar, Shidaling; Shivaraja, I.; Rayaprol, Sudhindra; Deshpande, S. K.; Angadi, Basavaraj
2018-04-01
The Pb0.7Bi0.3Fe0.65Nb0.35O3 (PBFNO) multiferroic solid solution was synthesized by using single step solid state reaction method. Single phase formation was confirmed through room temperature (RT) X Ray Diffraction (XRD) and Neutron Diffraction (ND). Rietveld refinement was used to perform the structural analysis using FullProf Suite program. RT XRD and ND patterns well fitted with monoclinic structure (Cm space group) and cell parameters from the ND data are found to be a = 5.6474(4) Å, b = 5.6415(3) Å, c = 3.9992(3) Å and β = 89.95(2)°. ND data at RT exhibits G-type antiferromagnetic structure. The electrical properties (impedance and modulus) of PBFNO were studied as a function of frequency (100 Hz - 5 MHz) and temperature (133 K - 293 K) by Impedance spectroscopy technique. Impedance and modulus spectroscopy studies confirm the contribution to the conductivity is from grains only and the relaxation is of non-Debye type. The PBFNO sample exhibits negative temperature coefficient of resistance (NTCR) behaviour. PBFNO is found be a potential candidate for RT applications.
Enhancing phonon flow through one-dimensional interfaces by impedance matching
NASA Astrophysics Data System (ADS)
Polanco, Carlos A.; Ghosh, Avik W.
2014-08-01
We extend concepts from microwave engineering to thermal interfaces and explore the principles of impedance matching in 1D. The extension is based on the generalization of acoustic impedance to nonlinear dispersions using the contact broadening matrix Γ(ω), extracted from the phonon self energy. For a single junction, we find that for coherent and incoherent phonons, the optimal thermal conductance occurs when the matching Γ(ω) equals the Geometric Mean of the contact broadenings. This criterion favors the transmission of both low and high frequency phonons by requiring that (1) the low frequency acoustic impedance of the junction matches that of the two contacts by minimizing the sum of interfacial resistances and (2) the cut-off frequency is near the minimum of the two contacts, thereby reducing the spillage of the states into the tunneling regime. For an ultimately scaled single atom/spring junction, the matching criterion transforms to the arithmetic mean for mass and the harmonic mean for spring constant. The matching can be further improved using a composite graded junction with an exponential varying broadening that functions like a broadband antireflection coating. There is, however, a trade off as the increased length of the interface brings in additional intrinsic sources of scattering.
Liu, Guozhen; Liu, Jingquan; Davis, Thomas P; Gooding, J Justin
2011-04-15
Electrodes modified with passivating organic layers have been shown to, here and previously, to exhibit good Faradaic electrochemistry upon attachment of gold nanoparticles (AuNP). Due to their low background capacitances these constructs have good potential in electrochemical sensing. Herein is reported the application of these electrode constructs for impedance based immunosensing. The immunosensor was constructed by modifying a gold electrode with 4-thiophenol (4-TP) passivating layers by diazonium salt chemistry. Subsequently, the attachment of AuNP and then a biotin derivative as a model epitope to detect anti-biotin IgG were carried out. The interfacial properties of the modified electrodes were evaluated in the presence of Fe(CN)(6)(4-/3-) redox couple as a probe by cyclic voltammetry and electrochemical impedance spectroscopy. The impedance change, due to the specific immuno-interaction at the immunosensor surface was utilized to detect anti-biotin IgG. The increase in charge-transfer resistance (R(ct)) was linearly proportional to the concentration of anti-biotin IgG in the range of 5-500 ng mL(-1), with a detection limit of 5 ng mL(-1). Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Rice, E. J.
1976-01-01
A liner design for noise suppressors with outer wall treatment such as in an engine inlet is presented which potentially circumvents the problems of resolution in modal measurement. The method is based on the fact that the modal optimum impedance and the maximum possible sound power attenuation at this optimum can be expressed as functions of cutoff ratio alone. Modes with similar cutoff ratios propagate similarly in the duct and in addition propagate similarly to the far field. Thus there is no need to determine the acoustic power carried by these modes individually, and they can be grouped together as one entity. With the optimum impedance and maximum attenuation specified as functions of cutoff ratio, the off-optimum liner performance can be estimated using an approximate attenuation equation.
NASA Astrophysics Data System (ADS)
Trautmann, L.; Petrausch, S.; Bauer, M.
2005-09-01
The functional transformation method (FTM) is an established mathematical method for accurate simulation of multidimensional physical systems from various fields of science, including optics, heat and mass transfer, electrical engineering, and acoustics. It is a frequency-domain method based on the decomposition into eigenvectors and eigenfrequencies of the underlying physical problem. In this article, the FTM is applied to real-time simulations of vibrating strings which are ideally fixed at one end while the fixing at the other end is modeled by a frequency-dependent input impedance. Thus, boundary conditions of third kind are applied to the model at the end fixed with the input impedance. It is shown that accurate and stable simulations are achieved with nearly the same computational cost as with strings ideally fixed at both ends.
NOTE: Impedance magnetocardiogram
NASA Astrophysics Data System (ADS)
Kandori, Akihiko; Miyashita, Tsuyoshi; Suzuki, Daisuke; Yokosawa, Koichi; Tsukada, Keiji
2001-02-01
We have developed an impedance magnetocardiogram (IMCG) system to detect the change of magnetic field corresponding to changes in blood volume in the heart. A low magnetic field from the electrical activity of the human heart - the so-called magnetocardiogram (MCG) - can be simultaneously detected by using this system. Because the mechanical and electrical functions in the heart can be monitored by non-invasive and non-contact measurements, it is easy to observe the cardiovascular functions from an accurate sensor position. This system uses a technique to demodulate induced current in a subject. A flux-locked circuit of a superconducting quantum interference device has a wide frequency range (above 1 MHz) because a constant current (40 kHz) is fed through the subject. It is shown for the first time that the system could measure IMCG signals at the same time as MCG signals.
NASA Astrophysics Data System (ADS)
Whalen, John J., III
Implantable electrical neurostimulating devices are being developed for a number of applications, including artificial vision through retinal stimulation. The epiretinal prosthesis will use a two-dimensional array microelectrodes to address individual cells of the retina. MEMS fabrication processes can produce arrays of microelectrodes with these dimensions, but there are two critical issues that they cannot satisfy. One, the stimulating electrodes are the only part of the implanted electrical device that penetrate through the water impermeable package, and must do so without sacrificing hermeticity. Two, As electrode size decreases, the current density (A cm-2 ) increases, due to increased electrochemical impedance. This reduces the amount of charge that can be safely injected into the tissue. To date, MEMS processing method, cannot produce electrode arrays with good, prolonged hermetic properties. Similarly, MEMS approaches do not account for the increased impedance caused by decreased surface area. For these reasons there is a strong motivation for the development of a water-impermeable, substrate-penetrating electrode array with low electrochemical impedance. This thesis presents a stimulating electrode array fabricated from platinum nanowires using a modified electrochemical template synthesis approach. Nanowires are electrochemically deposited from ammonium hexachloroplatinate solution into lithographically patterned nanoporous anodic alumina templates to produce microarrays of platinum nanowires. The platinum nanowires penetrating through the ceramic aluminum oxide template serve as parallel electrical conduits through the water impermeable, electrically insulating substrate. Electrode impedance can be adjusted by either controlling the nanowire hydrous platinum oxide content or by partially etching the alumina template to expose additional surface area. A stepwise approach to this project was taken. First, the electrochemistry of ammonium hexachloroplatinate solution was characterized, and physical properties of electrodeposited thin films were correlated to deposition conditions used. Second, platinum nanowires were fabricated and their properties characterized, using similar deposition conditions. Third, the feasibility of fabricating platinum nanowire stimulating electrode arrays with a variety of surface structures was demonstrated. Fourth, the enhanced charge transfer characteristics of these structures were demonstrated using electrochemical techniques. Finally, retinal cell stimulation was demonstrated using electrodes from platinum nanowire arrays.
Grain size effect on activation energy in spinel CoFe{sub 2}O{sub 4} ceramic
DOE Office of Scientific and Technical Information (OSTI.GOV)
Supriya, Sweety, E-mail: sweety@iitp.ac.in; Kumar, Sunil; Kar, Manoranjan
2016-05-23
Cobalt ferrite of different average crystallites (from nanocrystallite to micro crystallites) has been prepared by the Sol-Gel Method. The X-ray diffraction (XRD) analysis confirms the cubic spinel phase with no trace of impurity phases. The effect of annealing temperature on micro structure and electric transport properties as a function of frequency and temperature has been studied. It is observed that the electric impedance and conductivity are strongly dependent on grain size. The impedance spectroscopic study is employed to understand the electrical transport properties of cobalt ferrite.
Zhang, Diming; Jiang, Jing; Chen, Junye; Zhang, Qian; Lu, Yanli; Yao, Yao; Li, Shuang; Logan Liu, Gang; Liu, Qingjun
2015-08-15
Rapid, sensitive, selective and portable detection of 2,4,6-trinitrotoluene (TNT) is in high demand for public safety and environmental monitoring. In this study, we reported a smartphone-based system using impedance monitoring for TNT detection. The screen-printed electrodes modified with TNT-specific peptides were used as disposable a biosensor to produce impedance responses to TNT. The responses could be monitored by a hand-held device and send out to smartphone through Bluetooth. Then, the smartphone was used to display TNT responses in real time and report concentration finally. In the measurement, the system was demonstrated to detect TNT at concentration as low as 10(-6) M and distinguish TNT versus different chemicals in high specificity. Thus, the smartphone-based biosensing platform provided a convenient and efficient approach to design portable instruments for chemical detections such as TNT recognition. Copyright © 2015 Elsevier B.V. All rights reserved.
Methods for calculating the electrode position Jacobian for impedance imaging.
Boyle, A; Crabb, M G; Jehl, M; Lionheart, W R B; Adler, A
2017-03-01
Electrical impedance tomography (EIT) or electrical resistivity tomography (ERT) current and measure voltages at the boundary of a domain through electrodes. The movement or incorrect placement of electrodes may lead to modelling errors that result in significant reconstructed image artifacts. These errors may be accounted for by allowing for electrode position estimates in the model. Movement may be reconstructed through a first-order approximation, the electrode position Jacobian. A reconstruction that incorporates electrode position estimates and conductivity can significantly reduce image artifacts. Conversely, if electrode position is ignored it can be difficult to distinguish true conductivity changes from reconstruction artifacts which may increase the risk of a flawed interpretation. In this work, we aim to determine the fastest, most accurate approach for estimating the electrode position Jacobian. Four methods of calculating the electrode position Jacobian were evaluated on a homogeneous halfspace. Results show that Fréchet derivative and rank-one update methods are competitive in computational efficiency but achieve different solutions for certain values of contact impedance and mesh density.
Barrett, Caroline; Choksi, Yash; Vaezi, Michael F
2018-06-09
In this review, we discuss current diagnostic testing modalities for both gastroesophageal reflux disease (GERD) and eosinophilic esophagitis (EoE) and then introduce mucosal impedance (MI), a novel technology that measures epithelial integrity in real time during endoscopy. We describe the advantages and disadvantages of MI as compared with traditional diagnostic testing. We review studies that demonstrate that GERD and EoE have distinct MI patterns, and that physicians can accurately diagnose and distinguish the two during endoscopy with minimal time added to the procedure. We also review studies showing that MI has the capability to assess treatment response in both GERD and EoE and that it can be used to diagnose GERD in patients with extraesophageal reflux symptoms. Mucosal impedance testing is a major advancement in the diagnosis of GERD and EoE. Future studies are planned to assess whether MI can be used as a treatment endpoint in EoE and whether it can be used to predict response to anti-reflux surgery.
Coupling two spin qubits with a high-impedance resonator
NASA Astrophysics Data System (ADS)
Harvey, S. P.; Bøttcher, C. G. L.; Orona, L. A.; Bartlett, S. D.; Doherty, A. C.; Yacoby, A.
2018-06-01
Fast, high-fidelity single and two-qubit gates are essential to building a viable quantum information processor, but achieving both in the same system has proved challenging for spin qubits. We propose and analyze an approach to perform a long-distance two-qubit controlled phase (CPHASE) gate between two singlet-triplet qubits using an electromagnetic resonator to mediate their interaction. The qubits couple longitudinally to the resonator, and by driving the qubits near the resonator's frequency, they can be made to acquire a state-dependent geometric phase that leads to a CPHASE gate independent of the initial state of the resonator. Using high impedance resonators enables gate times of order 10 ns while maintaining long coherence times. Simulations show average gate fidelities of over 96% using currently achievable experimental parameters and over 99% using state-of-the-art resonator technology. After optimizing the gate fidelity in terms of parameters tuneable in situ, we find it takes a simple power-law form in terms of the resonator's impedance and quality and the qubits' noise bath.
Wang, Hsiang-Chen; Nguyen, Ngoc-Viet; Lin, Rui-Yi; Jen, Chun-Ping
2017-05-06
Analysis of cancerous cells allows us to provide useful information for the early diagnosis of cancer and to monitor treatment progress. An approach based on electrical principles has recently become an attractive technique. This study presents a microdevice that utilizes a dielectrophoretic impedance measurement method for the identification of cancerous cells. The proposed biochip consists of circle-on-line microelectrodes that are patterned using a standard microfabrication processes. A sample of various cell concentrations was introduced in an open-top microchamber. The target cells were collectively concentrated between the microelectrodes using dielectrophoresis manipulation, and their electrical impedance properties were also measured. Different stages of human esophageal squamous cell carcinoma lines could be distinguished. This result is consistent with findings using hyperspectral imaging technology. Moreover, it was observed that the distinguishing characteristics change in response to the progression of cancer cell invasiveness by Raman spectroscopy. The device enables highly efficient cell collection and provides rapid, sensitive, and label-free electrical measurements of cancerous cells.
On-Command Force and Torque Impeding Devices (OC-FTID) Using ERF
NASA Technical Reports Server (NTRS)
Bar-Cohen, Yoseph; Badescu, Mircea; Sherrit, Stewart
2014-01-01
Various machines have been developed to address the need for countermeasures of bone and muscle deterioration when humans operate over extended time in space. Even though these machines are in use, each of them has many limitations that need to be addressed in an effort to prepare for human missions to distant bodies in the solar system. An exercise exoskeleton was conceived that performs on-demand resistivity by inducing force and torque impedance via ElectroRheological Fluid (ERF). The resistive elements consist of pistons that are moving inside ERF-filled cylinders or a donut-shaped cavity, and the fluid flows through the piston when the piston is moved. Tests of the operation of ERF against load showed the feasibility of this approach. ERF properties of high yield stress, low current density, and fast response (less than one millisecond) offer essential characteristics for the construction of the exoskeleton. ERFs can apply very high electrically controlled resistive forces or torque while their size (weight and geometric parameters) can be very small. Their long life and ability to function in a wide temperature range (from -40 to 200 C) allows for their use in extreme environments. ERFs are also nonabrasive, non-toxic, and nonpolluting (meet health and safety regulations). The technology is applicable as a compact exercise machine for astronauts' countermeasure of microgravity, an exercise machine for sport, or as a device for rehabilitation of patients with limb issues.
Mathematics and Information Retrieval.
ERIC Educational Resources Information Center
Salton, Gerald
1979-01-01
Examines the main mathematical approaches to information retrieval, including both algebraic and probabilistic models, and describes difficulties which impede formalization of information retrieval processes. A number of developments are covered where new theoretical understandings have directly led to improved retrieval techniques and operations.…
Shiffman, Carl
2017-11-30
To define and elucidate the properties of reduced-variable Nyquist plots. Non-invasive measurements of the electrical impedance of the human thigh. A retrospective analysis of the electrical impedances of 154 normal subjects measured over the past decade shows that 'scaling' of the Nyquist plots for human thigh muscles is a property shared by healthy thigh musculature, irrespective of subject and the length of muscle segment. Here the term scaling signifies the near and sometimes 'perfect' coalescence of the separate X versus R plots into one 'reduced' Nyquist plot by the simple expedient of dividing R and X by X m , the value of X at the reactance maximum. To the extent allowed by noise levels one can say that there is one 'universal' reduced Nyquist plot for the thigh musculature of healthy subjects. There is one feature of the Nyquist curves which is not 'universal', however, namely the frequency f m at which the maximum in X is observed. That is found to vary from 10 to 100 kHz. depending on subject and segment length. Analysis shows, however, that the mean value of 1/f m is an accurately linear function of segment length, though there is a small subject-to-subject random element as well. Also, following the recovery of an otherwise healthy victim of ankle fracture demonstrates the clear superiority of measurements above about 800 kHz, where scaling is not observed, in contrast to measurements below about 400 kHz, where scaling is accurately obeyed. The ubiquity of 'scaling' casts new light on the interpretation of impedance results as they are used in electrical impedance myography and bioelectric impedance analysis.
DiffNet: automatic differential functional summarization of dE-MAP networks.
Seah, Boon-Siew; Bhowmick, Sourav S; Dewey, C Forbes
2014-10-01
The study of genetic interaction networks that respond to changing conditions is an emerging research problem. Recently, Bandyopadhyay et al. (2010) proposed a technique to construct a differential network (dE-MAPnetwork) from two static gene interaction networks in order to map the interaction differences between them under environment or condition change (e.g., DNA-damaging agent). This differential network is then manually analyzed to conclude that DNA repair is differentially effected by the condition change. Unfortunately, manual construction of differential functional summary from a dE-MAP network that summarizes all pertinent functional responses is time-consuming, laborious and error-prone, impeding large-scale analysis on it. To this end, we propose DiffNet, a novel data-driven algorithm that leverages Gene Ontology (go) annotations to automatically summarize a dE-MAP network to obtain a high-level map of functional responses due to condition change. We tested DiffNet on the dynamic interaction networks following MMS treatment and demonstrated the superiority of our approach in generating differential functional summaries compared to state-of-the-art graph clustering methods. We studied the effects of parameters in DiffNet in controlling the quality of the summary. We also performed a case study that illustrates its utility. Copyright © 2014 Elsevier Inc. All rights reserved.
A synergy-driven approach to a myoelectric hand.
Godfrey, S B; Ajoudani, A; Catalano, M; Grioli, G; Bicchi, A
2013-06-01
In this paper, we present the Pisa/IIT SoftHand with myoelectric control as a synergy-driven approach for a prosthetic hand. Commercially available myoelectric hands are more expensive, heavier, and less robust than their body-powered counterparts; however, they can offer greater freedom of motion and a more aesthetically pleasing appearance. The Pisa/IIT SoftHand is built on the motor control principle of synergies through which the immense complexity of the hand is simplified into distinct motor patterns. As the SoftHand grasps, it follows a synergistic path with built-in flexibility to allow grasping of a wide variety of objects with a single motor. Here we test, as a proof-of-concept, 4 myoelectric controllers: a standard controller in which the EMG signal is used only as a position reference, an impedance controller that determines both position and stiffness references from the EMG input, a standard controller with vibrotactile force feedback, and finally a combined vibrotactile-impedance (VI) controller. Four healthy subjects tested the control algorithms by grasping various objects. All controllers were sufficient for basic grasping, however the impedance and vibrotactile controllers reduced the physical and cognitive load on the user, while the combined VI mode was the easiest to use of the four. While these results need to be validated with amputees, they suggest a low-cost, robust hand employing hardware-based synergies is a viable alternative to traditional myoelectric prostheses.
NASA Astrophysics Data System (ADS)
Boulandet, R.; Michau, M.; Micheau, P.; Berry, A.
2016-01-01
This paper deals with an active structural acoustic control approach to reduce the transmission of tonal noise in aircraft cabins. The focus is on the practical implementation of the virtual mechanical impedances method by using sensoriactuators instead of conventional control units composed of separate sensors and actuators. The experimental setup includes two sensoriactuators developed from the electrodynamic inertial exciter and distributed over an aircraft trim panel which is subject to a time-harmonic diffuse sound field. The target mechanical impedances are first defined by solving a linear optimization problem from sound power measurements before being applied to the test panel using a complex envelope controller. Measured data are compared to results obtained with sensor-actuator pairs consisting of an accelerometer and an inertial exciter, particularly as regards sound power reduction. It is shown that the two types of control unit provide similar performance, and that here virtual impedance control stands apart from conventional active damping. In particular, it is clear from this study that extra vibrational energy must be provided by the actuators for optimal sound power reduction, mainly due to the high structural damping in the aircraft trim panel. Concluding remarks on the benefits of using these electrodynamic sensoriactuators to control tonal disturbances are also provided.
Developing a stability assessment method for power electronics-based microgrids
NASA Astrophysics Data System (ADS)
Austin, Peter M.
Modern microgrids with microsources and energy storage are dependent on power electronics for control and regulation. Under certain circumstances power electronics can be destabilizing to the system due to an effect called negative incremental impedance. A careful review of the theory and literature on the subject is presented. This includes stability criteria for both AC and DC systems, as well as a discussion on the limitations posed by the analysis. A method to integrate stability assessment with higher-level microgrid architectural design is proposed. Crucial to this is impedance characterization of individual components, which was accomplished through simulation. DC and AC impedance measurement blocks were created in Matlab simulink to automate the process. A detailed switching-level model of a DC microgrid was implemented in simulink, including wind turbine microsource, battery storage, and three phase inverter. Maximum power point tracking (MPPT) was included to maximize the efficiency of the turbine and was implemented through three rectifier alternatives and control schemes. The stability characteristics of each was compared in the final analysis. Impedance data was collected individually from the components and used to assess stability in the system as a whole. The results included the assessment of stability, margin, and unstable operating points to demonstrate the feasibility of the proposed approach.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cho, Youngho; Hur, Kyeon; Kang, Yong
This study investigates the emerging harmonic stability concerns to be addressed by grid planners in generation interconnection studies, owing to the increased adoption of renewable energy resources connected to the grid via power electronic converters. The wideband and high-frequency electromagnetic transient (EMT) characteristics of these converter-interfaced generators (CIGs) and their interaction with the grid impedance are not accurately captured in the typical dynamic studies conducted by grid planners. This paper thus identifies the desired components to be studied and subsequently develops a practical process for integrating a new CIG into a grid with the existing CIGs. The steps of thismore » process are as follows: the impedance equation of a CIG using its control dynamics and an interface filter to the grid, for example, an LCL filter (inductor-capacitor-inductor type), is developed; an equivalent impedance model including the existing CIGs nearby and the grid observed from the point of common coupling are derived; the system stability for credible operating scenarios is assessed. Detailed EMT simulations validate the accuracy of the impedance models and stability assessment for various connection scenarios. Here, by complementing the conventional EMT simulation studies, the proposed analytical approach enables grid planners to identify critical design parameters for seamlessly integrating a new CIG and ensuring the reliability of the grid.« less
Impedance-based cellular assays for regenerative medicine.
Gamal, W; Wu, H; Underwood, I; Jia, J; Smith, S; Bagnaninchi, P O
2018-07-05
Therapies based on regenerative techniques have the potential to radically improve healthcare in the coming years. As a result, there is an emerging need for non-destructive and label-free technologies to assess the quality of engineered tissues and cell-based products prior to their use in the clinic. In parallel, the emerging regenerative medicine industry that aims to produce stem cells and their progeny on a large scale will benefit from moving away from existing destructive biochemical assays towards data-driven automation and control at the industrial scale. Impedance-based cellular assays (IBCA) have emerged as an alternative approach to study stem-cell properties and cumulative studies, reviewed here, have shown their potential to monitor stem-cell renewal, differentiation and maturation. They offer a novel method to non-destructively assess and quality-control stem-cell cultures. In addition, when combined with in vitro disease models they provide complementary insights as label-free phenotypic assays. IBCA provide quantitative and very sensitive results that can easily be automated and up-scaled in multi-well format. When facing the emerging challenge of real-time monitoring of three-dimensional cell culture dielectric spectroscopy and electrical impedance tomography represent viable alternatives to two-dimensional impedance sensing.This article is part of the theme issue 'Designer human tissue: coming to a lab near you'. © 2018 The Author(s).
NASA Astrophysics Data System (ADS)
Polydorides, Nick; Lionheart, William R. B.
2002-12-01
The objective of the Electrical Impedance and Diffuse Optical Reconstruction Software project is to develop freely available software that can be used to reconstruct electrical or optical material properties from boundary measurements. Nonlinear and ill posed problems such as electrical impedance and optical tomography are typically approached using a finite element model for the forward calculations and a regularized nonlinear solver for obtaining a unique and stable inverse solution. Most of the commercially available finite element programs are unsuitable for solving these problems because of their conventional inefficient way of calculating the Jacobian, and their lack of accurate electrode modelling. A complete package for the two-dimensional EIT problem was officially released by Vauhkonen et al at the second half of 2000. However most industrial and medical electrical imaging problems are fundamentally three-dimensional. To assist the development we have developed and released a free toolkit of Matlab routines which can be employed to solve the forward and inverse EIT problems in three dimensions based on the complete electrode model along with some basic visualization utilities, in the hope that it will stimulate further development. We also include a derivation of the formula for the Jacobian (or sensitivity) matrix based on the complete electrode model.
Estimation of fatigue life using electromechanical impedance technique
NASA Astrophysics Data System (ADS)
Lim, Yee Yan; Soh, Chee Kiong
2010-04-01
Fatigue induced damage is often progressive and gradual in nature. Structures subjected to large number of fatigue load cycles will encounter the process of progressive crack initiation, propagation and finally fracture. Monitoring of structural health, especially for the critical components, is therefore essential for early detection of potential harmful crack. Recent advent of smart materials such as piezo-impedance transducer adopting the electromechanical impedance (EMI) technique and wave propagation technique are well proven to be effective in incipient damage detection and characterization. Exceptional advantages such as autonomous, real-time and online, remote monitoring may provide a cost-effective alternative to the conventional structural health monitoring (SHM) techniques. In this study, the main focus is to investigate the feasibility of characterizing a propagating fatigue crack in a structure using the EMI technique as well as estimating its remaining fatigue life using the linear elastic fracture mechanics (LEFM) approach. Uniaxial cyclic tensile load is applied on a lab-sized aluminum beam up to failure. Progressive shift in admittance signatures measured by the piezo-impedance transducer (PZT patch) corresponding to increase of loading cycles reflects effectiveness of the EMI technique in tracing the process of fatigue damage progression. With the use of LEFM, prediction of the remaining life of the structure at different cycles of loading is possible.
Groneberg, David A.
2016-01-01
We integrated recent improvements within the floating catchment area (FCA) method family into an integrated ‘iFCA`method. Within this method we focused on the distance decay function and its parameter. So far only distance decay functions with constant parameters have been applied. Therefore, we developed a variable distance decay function to be used within the FCA method. We were able to replace the impedance coefficient β by readily available distribution parameter (i.e. median and standard deviation (SD)) within a logistic based distance decay function. Hence, the function is shaped individually for every single population location by the median and SD of all population-to-provider distances within a global catchment size. Theoretical application of the variable distance decay function showed conceptually sound results. Furthermore, the existence of effective variable catchment sizes defined by the asymptotic approach to zero of the distance decay function was revealed, satisfying the need for variable catchment sizes. The application of the iFCA method within an urban case study in Berlin (Germany) confirmed the theoretical fit of the suggested method. In summary, we introduced for the first time, a variable distance decay function within an integrated FCA method. This function accounts for individual travel behaviors determined by the distribution of providers. Additionally, the function inherits effective variable catchment sizes and therefore obviates the need for determining variable catchment sizes separately. PMID:27391649
Knight, Alissa; Bryan, Janet; Murphy, Karen
2016-01-01
The rise in the ageing population has resulted in increased incident rates of cognitive impairment and dementia. The subsequent financial and societal burden placed on an already strained public health care system is of increasing concern. Evidence from recent studies has revealed modification of lifestyle and dietary behaviours is, at present, the best means of prevention. Some of the most important findings, in relation to the Mediterranean diet (MedDiet) and the contemporary Western diet, and potential molecular mechanisms underlying the effects of these two diets on age-related cognitive function, are discussed in this review. A major aim of this review was to discuss whether or not a MedDiet intervention would be a feasible preventative approach against cognitive decline for older adults living in Western countries. Critical appraisal of the literature does somewhat support this idea. Demonstrated evidence highlights the MedDiet as a potential strategy to reduce cognitive decline in older age, and suggests the Western diet may play a role in the aetiology of cognitive decline. However, strong intrinsic Western socio-cultural values, traditions and norms may impede on the feasibility of this notion. Copyright © 2015 Elsevier B.V. All rights reserved.
Terry Loghmani, M.; Bayliss, Amy J.; Clayton, Greg; Gundeck, Evelina
2015-01-01
Finger injuries are common and can greatly affect a musician’s quality of life. A 55-year-old man, who had injured the proximal interphalangeal joint of the left index finger 6 months prior to any intervention, was treated with a manual therapy approach incorporating instrument-assisted soft tissue mobilization (IASTM). Initial examination findings included self-reported pain and functional limitations and physical impairments that significantly impeded his ability to play the acoustic guitar. He was treated once a week for 6 weeks with IASTM, joint mobilization, therapeutic exercise, and ice massage. Additionally, a home exercise program and self-care instructions were provided. The patient gained positive outcomes with improvements in pain (Numerical Pain Rating Scale while playing the guitar: initial 5/10, discharge 1/10) and function (Disability Arm Shoulder Hand Sports-Performing Arts Optional Module: initial 75; discharge 6·25), each reaching a minimum clinically important difference. Importantly, he was able to play the guitar with minimal to no pain as desired. Physical measures also improved, including an immediate gain in finger range of motion with IASTM alone. Manual therapy approaches integrating IASTM may provide an effective conservative treatment strategy for patients with finger/hand conditions in the performing arts and other patient populations. PMID:26952165
The insulation performance of reactive parylene films in implantable electronic devices
Seymour, John P.; Elkasabi, Yaseen; Chen, Hsien-yeh; Lahann, Joerg; Kipke, Daryl R.
2009-01-01
Parylene-C (poly-chloro-p-xylylene) is an appropriate material for use in an implantable, microfabricated device. It is hydrophobic, conformally deposited, has a low dielectric constant, and superb biocompatibility. Yet for many bioelectrical applications, its poor wet adhesion may be an impassable shortcoming. This research contrasts parylene-C and poly(p-xylylene) functionalized with reactive group X (PPX-X) layers using long-term electrical soak and adhesion tests. The reactive parylene was made of complementary derivatives having aldehyde and aminomethyl side groups (PPX-CHO and PPX-CH2NH2 respectively). These functional groups have previously been shown to covalently react together after heating. Electrical testing was conducted in saline at 37°C on interdigitated electrodes with either parylene-C or reactive parylene as the metal layer interface. Results showed that reactive parylene devices maintained the highest impedance. Heat-treated PPX-X device impedance was 800% greater at 10 kHz and 70% greater at 1Hz relative to heated parylene-C controls after 60 days. Heat treatment proved to be critical for maintaining high impedance of both parylene-C and the reactive parylene. Adhesion measurements showed improved wet metal adhesion for PPX-X, which corresponds well with its excellent high frequency performance. PMID:19703712
NASA Astrophysics Data System (ADS)
Rocha, Paulo R. F.; Schlett, Paul; Kintzel, Ulrike; Mailänder, Volker; Vandamme, Lode K. J.; Zeck, Gunther; Gomes, Henrique L.; Biscarini, Fabio; de Leeuw, Dago M.
2016-10-01
Microelectrode arrays (MEA) record extracellular local field potentials of cells adhered to the electrodes. A disadvantage is the limited signal-to-noise ratio. The state-of-the-art background noise level is about 10 μVpp. Furthermore, in MEAs low frequency events are filtered out. Here, we quantitatively analyze Au electrode/electrolyte interfaces with impedance spectroscopy and noise measurements. The equivalent circuit is the charge transfer resistance in parallel with a constant phase element that describes the double layer capacitance, in series with a spreading resistance. This equivalent circuit leads to a Maxwell-Wagner relaxation frequency, the value of which is determined as a function of electrode area and molarity of an aqueous KCl electrolyte solution. The electrochemical voltage and current noise is measured as a function of electrode area and frequency and follow unambiguously from the measured impedance. By using large area electrodes the noise floor can be as low as 0.3 μVpp. The resulting high sensitivity is demonstrated by the extracellular detection of C6 glioma cell populations. Their minute electrical activity can be clearly detected at a frequency below about 10 Hz, which shows that the methodology can be used to monitor slow cooperative biological signals in cell populations.