Heist, E Kevin; Herre, John M; Binkley, Philip F; Van Bakel, Adrian B; Porterfield, James G; Porterfield, Linda M; Qu, Fujian; Turkel, Melanie; Pavri, Behzad B
2014-10-15
Detect Fluid Early from Intrathoracic Impedance Monitoring (DEFEAT-PE) is a prospective, multicenter study of multiple intrathoracic impedance vectors to detect pulmonary congestion (PC) events. Changes in intrathoracic impedance between the right ventricular (RV) coil and device can (RVcoil→Can) of implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy ICDs (CRT-Ds) are used clinically for the detection of PC events, but other impedance vectors and algorithms have not been studied prospectively. An initial 75-patient study was used to derive optimal impedance vectors to detect PC events, with 2 vector combinations selected for prospective analysis in DEFEAT-PE (ICD vectors: RVring→Can + RVcoil→Can, detection threshold 13 days; CRT-D vectors: left ventricular ring→Can + RVcoil→Can, detection threshold 14 days). Impedance changes were considered true positive if detected <30 days before an adjudicated PC event. One hundred sixty-two patients were enrolled (80 with ICDs and 82 with CRT-Ds), all with ≥1 previous PC event. One hundred forty-four patients provided study data, with 214 patient-years of follow-up and 139 PC events. Sensitivity for PC events of the prespecified algorithms was as follows: ICD: sensitivity 32.3%, false-positive rate 1.28 per patient-year; CRT-D: sensitivity 32.4%, false-positive rate 1.66 per patient-year. An alternative algorithm, ultimately approved by the US Food and Drug Administration (RVring→Can + RVcoil→Can, detection threshold 14 days), resulted in (for all patients) sensitivity of 21.6% and a false-positive rate of 0.9 per patient-year. The CRT-D thoracic impedance vector algorithm selected in the derivation study was not superior to the ICD algorithm RVring→Can + RVcoil→Can when studied prospectively. In conclusion, to achieve an acceptably low false-positive rate, the intrathoracic impedance algorithms studied in DEFEAT-PE resulted in low sensitivity for the prediction of heart failure events. Copyright © 2014 Elsevier Inc. All rights reserved.
Impedance analysis of acupuncture points and pathways
NASA Astrophysics Data System (ADS)
Teplan, Michal; Kukučka, Marek; Ondrejkovičová, Alena
2011-12-01
Investigation of impedance characteristics of acupuncture points from acoustic to radio frequency range is addressed. Discernment and localization of acupuncture points in initial single subject study was unsuccessfully attempted by impedance map technique. Vector impedance analyses determined possible resonant zones in MHz region.
BIOELECTRICAL IMPEDANCE VECTOR ANALYSIS IDENTIFIES SARCOPENIA IN NURSING HOME RESIDENTS
USDA-ARS?s Scientific Manuscript database
Loss of muscle mass and water shifts between body compartments are contributing factors to frailty in the elderly. The body composition changes are especially pronounced in institutionalized elderly. We investigated the ability of single-frequency bioelectrical impedance analysis (BIA) to identify b...
Bioelectrical impedance vector distribution in the first year of life.
Savino, Francesco; Grasso, Giulia; Cresi, Francesco; Oggero, Roberto; Silvestro, Leandra
2003-06-01
We assessed the bioelectrical impedance vector distribution in a sample of healthy infants in the first year of life, which is not available in literature. The study was conducted as a cross-sectional study in 153 healthy Caucasian infants (90 male and 63 female) younger than 1 y, born at full term, adequate for gestational age, free from chronic diseases or growth problems, and not feverish. Z scores for weight, length, cranial circumference, and body mass index for the study population were within the range of +/-1.5 standard deviations according to the Euro-Growth Study references. Concurrent anthropometrics (weight, length, and cranial circumference), body mass index, and bioelectrical impedance (resistance and reactance) measurements were made by the same operator. Whole-body (hand to foot) tetrapolar measurements were performed with a single-frequency (50 kHz), phase-sensitive impedance analyzer. The study population was subdivided into three classes of age for statistical analysis: 0 to 3.99 mo, 4 to 7.99 mo, and 8 to 11.99 mo. Using the bivariate normal distribution of resistance and reactance components standardized by the infant's length, the bivariate 95% confidence limits for the mean impedance vector separated by sex and age groups were calculated and plotted. Further, the bivariate 95%, 75%, and 50% tolerance intervals for individual vector measurements in the first year of life were plotted. Resistance and reactance values often fluctuated during the first year of life, particularly as raw measurements (without normalization by subject's length). However, 95% confidence ellipses of mean vectors from the three age groups overlapped each other, as did confidence ellipses by sex for each age class, indicating no significant vector migration during the first year of life. We obtained an estimate of mean impedance vector in a sample of healthy infants in the first year of life and calculated the bivariate values for an individual vector (95%, 75%, and 50% tolerance ellipses).
Ambulatory Monitoring of Congestive Heart Failure by Multiple Bioelectric Impedance Vectors
Khoury, Dirar S.; Naware, Mihir; Siou, Jeff; Blomqvist, Andreas; Mathuria, Nilesh S.; Wang, Jianwen; Shih, Hue-Teh; Nagueh, Sherif F.; Panescu, Dorin
2009-01-01
Objectives To investigate properties of multiple bioelectric impedance signals recorded during congestive heart failure (CHF) by utilizing various electrode configurations of an implanted cardiac resynchronization therapy (CRT) system. Background Monitoring of CHF has relied mainly on right-heart sensors. Methods Fifteen normal dogs underwent implantation of CRT systems using standard leads. An additional left atrial (LA) pressure lead-sensor was implanted in 5 dogs. Continuous rapid right ventricular (RV) pacing was applied over several weeks. Left ventricular (LV) catheterization and echocardiography were performed biweekly. Six steady-state impedance signals, utilizing intrathorcaic and intracardiac vectors, were measured via ring (r), coil (c), and device Can electrodes. Results All animals developed CHF after 2–4 weeks of pacing. Impedance diminished gradually during CHF induction, but at varying rates for different vectors. Impedance during CHF decreased significantly in all measured vectors: LVr-Can, −17%; LVr-RVr, −15%; LVr-RAr, −11%; RVr-Can, −12%; RVc-Can, −7%; RAr-Can, −5%. The LVr-Can vector reflected both the fastest and largest change in impedance in comparison to vectors employing only right-heart electrodes, and was highly reflective of changes in LV end-diastolic volume and LA pressure. Conclusions Impedance, acquired via different lead-electrodes, have variable responses to CHF. Impedance vectors employing a LV lead are highly responsive to physiologic changes during CHF. Measuring multiple impedance signals could be useful for optimizing ambulatory monitoring in heart failure patients. PMID:19298923
NASA Astrophysics Data System (ADS)
Thomson, C. J.
2015-08-01
The properties of the overburden transmission response are of particular interest for the analysis of reflectivity illumination or blurring in seismic depth imaging. The first step to showing a transmission-operator reciprocity property is to identify the symmetry of the so-called displacement-to-traction operators. The latter are analogous to Dirichlet-to-Neumann operators and they may also be called impedance operators. Their symmetry is deduced here after development of a formal spectral or modal theory of lateral wavefunctions in a laterally heterogeneous generally anisotropic elastic medium. The elastic lateral modes are displacement-traction 6-vectors and they are built from two auxiliary 3-vector lateral-mode bases. These auxiliary modes arise from Hermitian and anti-Hermitian operators, so they have familiar properties such as orthogonality. There is no assumption of down/up symmetry of the elasticity tensor, but basic assumptions are made about the existence and completeness of the elastic modes. A point-symmetry property appears and plays a central role. The 6-vector elastic modes have a symplectic orthogonality property, which facilitates the development of modal expansions for 6-vector functions of the lateral coordinates when completeness is assumed. While the elastic modal theory is consistent with the laterally homogeneous case, numerical work would provide confidence that it is correct in general. An appendix contains an introductory overview of acoustic lateral modes that were studied by other authors, given from the perspective of this new work. A distinction is drawn between unit normalization of scalar auxiliary modes and a separate energy-flux normalization of 2-vector acoustic modes. Neither is crucial to the form of acoustic pressure-to-velocity or impedance operators. This statement carries over to the elastic case for the 3-vector auxiliary- and 6-vector elastic-mode normalizations. The modal theory is used to construct the kernel of the elastic displacement-to-traction or impedance operator. Symmetry properties of this operator are then deduced, which is the main goal of this paper. The implications of elastic impedance-operator symmetry and the symplectic property for the transmission and reflection responses of finite regions are described in a companion paper.
Feasibility of Bioelectrical Impedance Spectroscopy Measurement before and after Thoracentesis
Weyer, Sören; Pauly, Karolin; Napp, Andreas; Dreher, Michael; Leonhardt, Steffen; Marx, Nikolaus; Schauerte, Patrick; Mischke, Karl
2015-01-01
Background. Bioelectrical impedance spectroscopy is applied to measure changes in tissue composition. The aim of this study was to evaluate its feasibility in measuring the fluid shift after thoracentesis in patients with pleural effusion. Methods. 45 participants (21 with pleural effusion and 24 healthy subjects) were included. Bioelectrical impedance was analyzed for “Transthoracic,” “Foot to Foot,” “Foot to Hand,” and “Hand to Hand” vectors in low and high frequency domain before and after thoracentesis. Healthy subjects were measured at a single time point. Results. The mean volume of removed pleural effusion was 1169 ± 513 mL. The “Foot to Foot,” “Hand to Hand,” and “Foot to Hand” vector indicated a trend for increased bioelectrical impedance after thoracentesis. Values for the low frequency domain in the “Transthoracic” vector increased significantly (P < 0.001). A moderate correlation was observed between the amount of removed fluid and impedance change in the low frequency domain using the “Foot to Hand” vector (r = −0.7). Conclusion. Bioelectrical impedance changes in correlation with the thoracic fluid level. It was feasible to monitor significant fluid shifts and loss after thoracentesis in the “Transthoracic” vector by means of bioelectrical impedance spectroscopy. The trial is registered with Registration Numbers IRB EK206/11 and NCT01778270. PMID:25861647
Fassini, Priscila Giacomo; Nicoletti, Carolina Ferreira; Pfrimer, Karina; Nonino, Carla Barbosa; Marchini, Júlio Sérgio; Ferriolli, Eduardo
2017-08-01
Short bowel syndrome (SBS) represents a serious intestinal absorption disorder. Therefore, patients with SBS may have severe malnutrition and excessive mineral and fluid losses. Once the assessment of nutritional status is important in their follow-up, body composition measurements and especially total body water (TBW) must be repeatedly evaluated for the assessment of changes in hydration and nutritional care. The aim of this study was to investigate if bioelectrical impedance vector analysis (BIVA) is a useful predictor of nutritional and hydration status in SBS patients. In this observational study, 22 participants (12 women), 11 with SBS and 11 gender, age and BMI-matched controls, were evaluated using the bioelectrical impedance measurements (BIA) and BIVA to assess nutritional and hydration status. Participants age was 53 ± 8 y (mean ± SD). Body water, fat mass and lean mass as assessed by BIA did not differ between the two groups. However, BIVA showed important differences between the groups regarding hydration and amount of soft tissue (p < 0.0001 for women and p = 0.0015 for men). The results also evidenced that women's vectors were related to cachexia, while men's vectors were divided into lean and cachexia quadrants. The use of BIVA analysis also evidenced hydration disturbance and losses of soft tissue. BIVA may represent a better predictor of nutritional status for analysis and interpretation of body composition in patients with short bowel syndrome. This trial was registered at ClinicalTrials.gov as NCT02113228. Copyright © 2016 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Bioelectrical Impedance Vector Analysis and Muscular Fitness in Healthy Men
Rodríguez-Rodríguez, Fernando; Cristi-Montero, Carlos; González-Ruíz, Katherine; Correa-Bautista, Jorge Enrique; Ramírez-Vélez, Robinson
2016-01-01
Muscle strength can define the general muscular fitness (MF) measurable through hand-grip strength (HG), which is a factor that relates to the health of people of different ages. In this study we evaluated the muscle strength together with a bioimpedance electric analysis in 223 healthy Colombian adult subjects. The bioelectrical impedance vector analysis (BIVA) was conducted to determine the resistance (R), reactance (Xc) and phase angle (PhA). We classified the subjects into three groups (for tertiles), obtaining lower values of R and Xc in subjects with lower HG, plus a high correlation between PhA and HG. An increase in the level of PhA is associated with a high level of MF in a sample of healthy Latin American adult men. The BIVA’s parameters and PhA are a potentially effective preventive measure to be integrated into routine screening in the clinical setting. PMID:27384579
NASA Astrophysics Data System (ADS)
Chen, Jiangwei; Dai, Yuyao; Yan, Lin; Zhao, Huimin
2018-04-01
In this paper, we shall demonstrate theoretically that steady bound electromagnetic eigenstate can arise in an infinite homogeneous isotropic linear metamaterial with zero-real-part-of-impedance and nonzero-imaginary-part-of-wave-vector, which is partly attributed to that, here, nonzero-imaginary-part-of-wave-vector is not involved with energy losses or gain. Altering value of real-part-of-impedance of the metamaterial, the bound electromagnetic eigenstate may become to be a progressive wave. Our work may be useful to further understand energy conversion and conservation properties of electromagnetic wave in the dispersive and absorptive medium and provides a feasible route to stop, store and release electromagnetic wave (light) conveniently by using metamaterial with near-zero-real-part-of-impedance.
Smart Multi-Frequency Bioelectrical Impedance Spectrometer for BIA and BIVA Applications.
Harder, Rene; Diedrich, Andre; Whitfield, Jonathan S; Buchowski, Macie S; Pietsch, John B; Baudenbacher, Franz J
2016-08-01
Bioelectrical impedance analysis (BIA) is a noninvasive and commonly used method for the assessment of body composition including body water. We designed a small, portable and wireless multi-frequency impedance spectrometer based on the 12 bit impedance network analyzer AD5933 and a precision wide-band constant current source for tetrapolar whole body impedance measurements. The impedance spectrometer communicates via Bluetooth with mobile devices (smart phone or tablet computer) that provide user interface for patient management and data visualization. The export of patient measurement results into a clinical research database facilitates the aggregation of bioelectrical impedance analysis and biolectrical impedance vector analysis (BIVA) data across multiple subjects and/or studies. The performance of the spectrometer was evaluated using a passive tissue equivalent circuit model as well as a comparison of body composition changes assessed with bioelectrical impedance and dual-energy X-ray absorptiometry (DXA) in healthy volunteers. Our results show an absolute error of 1% for resistance and 5% for reactance measurements in the frequency range of 3 kHz to 150 kHz. A linear regression of BIA and DXA fat mass estimations showed a strong correlation (r(2)=0.985) between measures with a maximum absolute error of 6.5%. The simplicity of BIA measurements, a cost effective design and the simple visual representation of impedance data enables patients to compare and determine body composition during the time course of a specific treatment plan in a clinical or home environment.
Nwosu, Amara Callistus; Mayland, Catriona R; Mason, Stephen R; Khodabukus, Andrew F; Varro, Andrea; Ellershaw, John E
2013-09-01
Decisions surrounding the administration of clinically assisted hydration to patients dying of cancer can be challenging because of the limited understanding of hydration in advanced cancer and a lack of evidence to guide health care professionals. Bioelectrical impedance analysis (BIA) has been used to assess hydration in various patient groupings, but evidence for its use in advanced cancer is limited. To critically appraise existing methods of hydration status assessment in advanced cancer and review the potential for BIA to assess hydration in advanced cancer. Searches were carried out in four electronic databases. A hand search of selected peer-reviewed journals and conference abstracts also was conducted. Studies reporting (de)hydration assessment (physical examination, biochemical measures, symptom assessment, and BIA) in patients with advanced cancer were included. The results highlight how clinical examination and biochemical tests are standard methods of assessing hydration, but limitations exist with these methods in advanced cancer. Furthermore, there is disagreement over the evidence for some commonly associated symptoms with dehydration in cancer. Although there are limitations with using BIA alone to assess hydration in advanced cancer, analysis of BIA raw measurements through the method of bioelectrical impedance vector analysis may have a role in this population. The benefits and burdens of providing clinically assisted hydration to patients dying of cancer are unclear. Bioelectrical impedance vector analysis shows promise as a hydration assessment tool but requires further study in advanced cancer. Innovative methodologies for research are required to add to the evidence base and ultimately improve the care for the dying. Copyright © 2013 U.S. Cancer Pain Relief Committee. Published by Elsevier Inc. All rights reserved.
Hise, Ana Cláudia da Rosa; Gonzalez, Maria Cristina
2018-04-01
The state of hyperhydration in critically ill patients with acute kidney injury (AKI) is associated with increased mortality. Bioelectrical impedance vector analysis (BIVA) appears to be a viable method to access the fluid status of critical patients but has never been evaluated in critical patients with AKI. The objective of this study is to evaluate the hydration status measured using BIVA in critical patients under intensive care at the time of AKI diagnosis and to correlate this measurement with mortality. We assessed the fluid status measured using BIVA in 224 critical patients at the time of AKI diagnosis and correlated it with mortality. To interpret the results, BIVA Software 2002 was used to plot the data from the patients studied on the 95% confidence ellipses of the RX c plane for comparisons between groups (non-survivors, survivors). Variables such as mechanical ventilation, vasoactive drug, and sepsis, among others, were collected. The impedance vector analysis conducted using BIVA Software 2002 indicated changes in the body compositions of patients according to the 95% confidence ellipse between the vectors R/H and X c /H of the group of survivors and the group of deceased patients. Hotelling's test (T 2 = 21.2) and the F test (F = 10.6) revealed significant differences (p < 0.001) between the two groups. These results demonstrate that patients who died presented with a greater hydration volume at the time of AKI diagnosis compared with those who survived. In addition to the hydration status measured using BIVA, the following were also correlated with death: diagnosis at hospitalization, APACHE II score, length of hospital stay, RIFLE score, maximum organ failure, sepsis type, hemoglobin, and AF. The fluid status assessment measured using BIVA significantly demonstrated the difference in hydration between survivors and non-survivors among critically ill patients with AKI. Copyright © 2017 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Acute evaluation of transthoracic impedance vectors using ICD leads.
Gottfridsson, Christer; Daum, Douglas; Kennergren, Charles; Ramuzat, Agnès; Willems, Roger; Edvardsson, Nils
2009-06-01
Minute ventilation (MV) has been proven to be very useful in rate responsive pacing. The aim of this study was to evaluate the feasibility of using implantable cardioverter-defibrillator (ICD) leads as part of the MV detection system. At implant in 10 patients, the transthoracic impedance was measured from tripolar ICD, tetrapolar ICD, and atrial lead vectors during normal, deep, and shallow voluntary respiration. MV and respiration rate (RespR) were simultaneously measured through a facemask with a pneumotachometer (Korr), and the correlations with impedance-based measurements were calculated. Air sensitivity was the change in impedance per change in respiratory tidal volume, ohms (Omega)/liter (L), and the signal-to-noise ratio (SNR) was the ratio of the respiratory and cardiac contraction components. The air sensitivity and SNR in tripolar ICD vector were 2.70 +/- 2.73 ohm/L and 2.19 +/- 1.31, respectively, and were not different from tetrapolar. The difference in RespR between tripolar ICD and Korr was 0.2 +/- 1.91 breaths/minute. The regressed correlation coefficient between impedance MV and Korr MV was 0.86 +/- 0.07 in tripolar ICD. The air sensitivity and SNR in tripolar and tetrapolar ICD lead vectors did not differ significantly and were in the range of the values in pacemaker leads currently used as MV sensors. The good correlations between impedance-based and Korr-based RespR and MV measurements imply that ICD leads may be used in MV sensor systems.
Cova, Ilaria; Pomati, Simone; Maggiore, Laura; Forcella, Marica; Cucumo, Valentina; Ghiretti, Roberta; Grande, Giulia; Muzio, Fulvio; Mariani, Claudio
2017-01-01
Analysis of nutritional status and body composition in Alzheimer's disease (AD) and Mild Cognitive Impairment (MCI). A cross-sectional study was performed in a University-Hospital setting, recruiting 59 patients with AD, 34 subjects with MCI and 58 elderly healthy controls (HC). Nutritional status was assessed by anthropometric parameters (body mass index; calf, upper arm and waist circumferences), Mini Nutritional Assessment (MNA) and body composition by bioelectrical impedance vector analysis (BIVA). Variables were analyzed by analysis of variance and subjects were grouped by cognitive status and gender. Sociodemographic variables did not differ among the three groups (AD, MCI and HC), except for females' age, which was therefore used as covariate in a general linear multivariate model. MNA score was significantly lower in AD patients than in HC; MCI subjects achieved intermediate scores. AD patients (both sexes) had significantly (p<0.05) higher height-normalized impedance values and lower phase angles (body cell mass) compared with HC; a higher ratio of impedance to height was found in men with MCI with respect to HC. With BIVA method, MCI subjects showed a significant displacement on the RXc graph on the right side indicating lower soft tissues (Hotelling's T2 test: men = 10.6; women = 7.9;p < 0,05) just like AD patients (Hotelling's T2 test: men = 18.2; women = 16.9; p<0,001). Bioelectrical parameters significantly differ from MCI and AD to HC; MCI showed an intermediate pattern between AD and HC. Longitudinal studies are required to investigate if BIVA could reflect early AD-changes in body composition in subjects with MCI.
Control of Electromagnetic Scattering by Antenna Impedance Loading
1974-07-01
system and whose profile in a plane perpendicular to the z axis is the closed curve c. Let n be an outward unit vector to c and let t be a unit... vector in the tangential direction, such that t, n and z form a right-hand system. Then, on the surface, the impedance boundary con- dition is...and is given by J Mn x z)H* where n is the unit outward normal vector to the surface. Using the GTD solution for the total magnetic field, the
[Bioimpedance vector analysis for body composition in Mexican population].
Espinosa-Cuevas, Maria de los Angeles; Rivas-Rodríguez, Lucía; González-Medina, Enna Cristal; Atilano-Carsi, Ximena; Miranda-Alatriste, Paola; Correa-Rotter, Ricardo
2007-01-01
To construct bivariate tolerance ellipses from impedance values normalized for height, which can be used in Mexican population for the assessment of body composition and compare them with others made in different populations. Body composition was assessed by bioelectrical impedance analysis (BIA) in 439 subjects (204 men and 235 women), 18 to 82 years old, with a BMI between 18-31, using an impedanciometer Quadscan 4000. Resistance, reactance and phase angle were used to calculate bioelectrical impedance vectors and construct bivariate tolerance ellipses. Mean age in men was 47.1 +/- 16 years and 42.4 +/- 13 for women, mean weight (73.4 + 9 vs. 60.1 + 8 kg) and height (1.68 vs. 1.55 m) were significant greater in men than in women (p < 0.002). Women in comparison with men, had greater values of impedance (622.96 +/- 66.16 S2 vs. 523.59 +/- 56.56 D) and resistance (618.96 +/- 66.10 Q 61.97 vs. 521.73 +/- 61.97 2), as well as of resistance and reactance standardized by height (398.24 +/-46.30 S2/m vs. 308.66 +/- 38.44) (44.32 +/- 7.14 i/m vs. 39.75 +/-6.29) respectively, with a significant difference in all of them (p < 0.0001). Similarly, the reactance was greater in females, nevertheless this difference did not reach statistical significance (68.96 +/- 11.17 vs. 67.18 +/- 10.3; p = 0.0861). The phase angle was greater in men than in women, with a statistically significant difference (7.330 +/- 0.88 vs. 6.360 +/- 0.97; p < 0.0001). Bivariate tolerance ellipses (50%, 75% and 95%) derived from Mexican subjects showed a significant upward deviation (p < 0.05) from previously published references from Mexican American and Italian populations. New ellipses of tolerance were therefore constructed for the Mexican population. Bioimpedance vectors in Mexican subjects are significantly different from the existing ones, supporting the need of population specific bivariate tolerance ellipses for the evaluation of body composition.
Carrasco-Marginet, Marta; Castizo-Olier, Jorge; Rodríguez-Zamora, Lara; Iglesias, Xavier; Rodríguez, Ferran A.; Chaverri, Diego; Brotons, Daniel
2017-01-01
Purpose The assessment of body hydration is a complex process, and no measurement is valid for all situations. Bioelectrical impedance vector analysis (BIVA) has emerged as a relatively novel technique for assessing hydration status in sports. We applied BIVA a) to determine hydration changes evoked by an intense synchronized swimming (SS) training session; b) to characterize the sample of young elite swimmers in relation with a nonathletic reference population; and c) to generate its 50%, 75% and 95% percentiles of the bioelectrical variables. Methods Forty-nine elite SS female swimmers of two age categories, comen (Co: 13.9 ± 0.9 years, n = 34) and junior (Jr: 16.3 ± 0.6 years, n = 15), performed a long, high intensity training session. Body mass (BM) and bioelectrical variables (R, resistance; Xc, reactance; PA, phase angle; and Z, impedance module) were assessed pre- and post-training. BIVA was used to characterize 1) the distribution pattern of the bioelectrical vector (BIA vector) for both age groups, and 2) pre- to post-training BIA vector migration. Bioelectrical variables were also correlated with BM change values. Results Most swimmers were mostly located outside the 75% and some beyond the 95% percentile of the bioelectrical tolerance ellipses of the general population. The BIA vector showed statistically significant differences in both Co (T2 = 134.7, p = 0.0001) and Jr (T2 = 126.2, p < 0.001). Both groups were also bioelectrically different (T2 = 17.6, p < 0.001). After the training session, a decrease in BM (p = 0.0001) and an increase in BIA variables (p = 0.01) was observed. BIVA also showed a significant pre-post vector migration both in Co (T2 = 82.1; p < 0.001) and Jr (T2 = 41.8; p < 0.001). No correlations were observed between BM changes and bioelectrical variables. Conclusions BIVA showed specific bioelectrical characteristics in young elite SS athletes. Considering the decrease in BM and the migration of the BIA vector, we conclude that the homeostatic hydration status of these young elite female swimmers was affected by the execution of intense training sessions. From a methodological perspective, BIVA appears to be sensitive enough to detect subtle hydration changes, but further research is needed to ensure its validity and reliability. Moreover, these findings highlight the importance of ensuring adequate fluid intake during training in young SS athletes. PMID:28591135
USDA-ARS?s Scientific Manuscript database
The potential for gut microbiota to impede or enhance pathogen transmission is well-documented but the factors that shape this microbiota in mosquito vectors are poorly understood. We characterized and compared the gut microbiota of adult females of Culex restuans Theobald from different parents. Cu...
Geladi, Paul; Nelson, Andrew; Lindholm-Sethson, Britta
2007-07-09
Electrical impedance gives multivariate complex number data as results. Two examples of multivariate electrical impedance data measured on lipid monolayers in different solutions give rise to matrices (16x50 and 38x50) of complex numbers. Multivariate data analysis by principal component analysis (PCA) or singular value decomposition (SVD) can be used for complex data and the necessary equations are given. The scores and loadings obtained are vectors of complex numbers. It is shown that the complex number PCA and SVD are better at concentrating information in a few components than the naïve juxtaposition method and that Argand diagrams can replace score and loading plots. Different concentrations of Magainin and Gramicidin A give different responses and also the role of the electrolyte medium can be studied. An interaction of Gramicidin A in the solution with the monolayer over time can be observed.
Body fluid volume and nutritional status in hemodialysis: vector bioelectric impedance analysis.
Espinosa Cuevas, M A; Navarrete Rodriguez, G; Villeda Martinez, M E; Atilano Carsi, X; Miranda Alatriste, P; Tostado Gutiérrez, T; Correa-Rotter, R
2010-04-01
Protein-energy malnutrition and hypervolemia are major causes of morbidity and mortality in patients on chronic hemodialysis (CHD). The methods used to evaluate nutritional status and volume status remain controversial. Vector bioelectric impedance analysis (vector- BIA) has recently been developed to assess both nutritional status and tissue hydration. The purpose of the study was to assess the nutritional status and volume status of patients on CHD with conventional nutritional assessment methods and with vector-BIA and then to compare the resulting findings. 76 Mexican patients on CHD were studied. Nutritional status and body composition were assessed with anthropometry, biochemical variables, and the modified Bilbrey nutritional index (mBNI), the results were compared with both conventional BIA and vector-BIA. The BNI was used to determine the number of patients with normal nutritional status (n = 27, 35.5%), and mild (n = 31, 40.8%), moderate (n = 10, 13.2%) and severe malnutrition (n = 8, 10.5%). Patients displayed shorter vectors with smaller phase angles or with an overhydration vectorial pattern before the initiation of their hemodialysis session. There was general improvement to normal hydration status post-dialysis (p < 0.05); however, 28% remained overhydrated as assessed by vector-BIA. The vector-BIA results showed that worse malnutrition status was associated with greater volume overload (p < 0.05). Diabetes mellitus (DM) was associated with shorter vectors with smaller phase angles (a vectorial pattern of overhydration and cachexia) (p < 0.05). Patients with lower serum creatinine presented with shorter vectors and smaller phase angles (vectorial patterns of malnutrition and/or overhydration) (p < 0.05). In women, lower serum albumin (< 3.4 g/dl) correlated with greater overhydration and malnutrition (p < 0.05). In this population, the vector-BIA showed that 28% of the population remained overhydrated after their hemodialysis session. Diabetics and those with moderate or severe malnutrition were more overhydrated, which is a condition that may be associated with increased cardiovascular morbidity. Because nutritional and volume status are important factors associated with morbidity and mortality in CHD patients, we focused on optimizing the use of existing methods. Our studies suggest that vector-BIA offers a comprehensive and reliable reproducible means of assessing both volume and masses at the bedside and can complement the traditional methods.
Ding, Yi S; He, Yang
2017-08-21
An isotropic impedance sheet model is proposed for a loop-type hexagonal periodic metasurface. Both frequency and wave-vector dispersion are considered near the resonance frequency. Therefore both the angle and polarization dependences of the metasurface impedance can be properly and simultaneously described in our model. The constitutive relation of this model is transformed into auxiliary differential equations which are integrated into the finite-difference time-domain algorithm. Finally, a finite large metasurface sample under oblique illumination is used to test the model and the algorithm. Our model and algorithm can significantly increase the accuracy of the homogenization methods for modeling periodic metasurfaces.
Application of Artificial Boundary Conditions in Sensitivity-Based Updating of Finite Element Models
2007-06-01
is known as the impedance matrix[ ]( )Z Ω . [ ] [ ] 1( ) ( )Z H −Ω = Ω (12) where [ ] 2( )Z K M j C ⎡ ⎤Ω = −Ω + Ω⎣ ⎦ (13) A. REDUCED ORDER...D.L. A correlation coefficient for modal vector analysis. Proceedings of 1st International Modal Analysis Conference, 1982, 110-116. Anton , H ... Rorres , C ., (2005). Elementary Linear Algebra. New York: John Wiley and Sons. Avitable, Peter (2001, January) Experimental Modal Analysis, A Simple
Hauschild, Daniela Barbieri; Barbosa, Eliana; Moreira, Emilia Addison Machado; Ludwig Neto, Norberto; Platt, Vanessa Borges; Piacentini Filho, Eduardo; Wazlawik, Elisabeth; Moreno, Yara Maria Franco
2016-06-01
(1) To compare nutrition and hydration status between a group of children/adolescents with cystic fibrosis (CFG; n = 46; median age, 8.5 years) and a control group without cystic fibrosis (CG). (2) To examine the association of nutrition and hydration status with lung function in the CFG. A cross-sectional study. Nutrition screening, anthropometric parameters, and bioelectrical impedance analysis (BIA) were assessed. The z scores for body mass index for age, height for age, mid upper arm circumference, triceps and subscapular skinfold thickness, mid upper arm muscle area, resistance/height, and reactance/height were calculated. Bioelectrical impedance vector analysis was conducted. Forced expiratory volume in 1 second <80% was considered lung function impairment. An adjusted logistic regression was applied (P < .05). In the CFG, lung function impairment was observed in 51.1%. All anthropometric parameters were lower, and the mean z-resistance/height and z-reactance/height were higher in the CFG (P < .05) compared with the CG. In the CFG, 43% were severely/mildly dehydrated, while none were in the CG (P = .007). In the CFG, there was an association between high nutrition risk-via nutrition screening (odds ratio [OR], 22.28; P < .05), lower values of anthropometric parameters, higher z-resistance/height (OR, 2.23; P < .05) and z-reactance/height (OR, 1.81; P < .05), and dehydration (OR, 4.94; P < .05)-and lung function impairment. The CFG exhibited a compromised nutrition status assessed by anthropometric and BIA parameters. Nutrition screening, anthropometric and BIA parameters, and hydration status were associated with lung function. © 2016 American Society for Parenteral and Enteral Nutrition.
Bioimpedance Identifies Body Fluid Loss after Exercise in the Heat: A Pilot Study with Body Cooling
Gatterer, Hannes; Schenk, Kai; Laninschegg, Lisa; Schlemmer, Philipp; Lukaski, Henry; Burtscher, Martin
2014-01-01
Purpose Assessment of post-exercise changes in hydration with bioimpedance (BI) is complicated by physiological adaptations that affect resistance (R) and reactance (Xc) values. This study investigated exercise-induced changes in R and Xc, independently and in bioelectrical impedance vector analysis, when factors such as increased skin temperature and blood flow and surface electrolyte accumulation are eliminated with a cold shower. Methods Healthy males (n = 14, 24.1±1.7 yr; height (H): 182.4±5.6 cm, body mass: 72.3±6.3 kg) exercised for 1 hr at a self-rated intensity (15 BORG) in an environmental chamber (33°C and 50% relative humidity), then had a cold shower (15 min). Before the run BI, body mass, hematocrit and Posm were measured. After the shower body mass was measured; BI measurements were performed continuously every 20 minutes until R reached a stable level, then hematocrit and Posm were measured again. Results Compared to pre-trial measurements body mass decreased after the run and Posm, Hct, R/H and Xc/H increased (p<0.05) with a corresponding lengthening of the impedance vector along the major axis of the tolerance ellipse (p<0.001). Changes in Posm were negatively related to changes in body mass (r = −0.564, p = 0.036) and changes in Xc/H (r = −0.577, p = 0.041). Conclusions Present findings showed that after a bout of exercise-induced dehydration followed by cold shower the impedance vector lengthened that indicates fluid loss. Additionally, BI values might be useful to evaluate fluid shifts between compartments as lower intracellular fluid loss (changed Xc/R) indicated greater Posm increase. PMID:25279660
Detection of needle to nerve contact based on electric bioimpedance and machine learning methods.
Kalvoy, Havard; Tronstad, Christian; Ullensvang, Kyrre; Steinfeldt, Thorsten; Sauter, Axel R
2017-07-01
In an ongoing project for electrical impedance-based needle guidance we have previously showed in an animal model that intraneural needle positions can be detected with bioimpedance measurement. To enhance the power of this method we in this study have investigated whether an early detection of the needle only touching the nerve also is feasible. Measurement of complex impedance during needle to nerve contact was compared with needle positions in surrounding tissues in a volunteer study on 32 subjects. Classification analysis using Support-Vector Machines demonstrated that discrimination is possible, but that the sensitivity and specificity for the nerve touch algorithm not is at the same level of performance as for intra-neuralintraneural detection.
ERIC Educational Resources Information Center
Bureau of Naval Personnel, Washington, DC.
The module covers series circuits which contain both resistive and reactive components and methods of solving these circuits for current, voltage, impedance, and phase angle. The module is divided into six lessons: voltage and impedance in AC (alternating current) series circuits, vector computations, rectangular and polar notation, variational…
PGE(2) activation of apical membrane Cl(-) channels in A6 epithelia: impedance analysis.
Păunescu, T G; Helman, S I
2001-01-01
Measurements of transepithelial electrical impedance of continuously short-circuited A6 epithelia were made at audio frequencies (0.244 Hz to 10.45 kHz) to investigate the time course and extent to which prostaglandin E(2) (PGE(2)) modulates Cl(-) transport and apical membrane capacitance in this cell-cultured model epithelium. Apical and basolateral membrane resistances were determined by nonlinear curve-fitting of the impedance vectors at relatively low frequencies (<50 Hz) to equations (Păunescu, T. G., and S. I. Helman. 2001. Biophys. J. 81:838--851) where depressed Nyquist impedance semicircles were characteristic of the membrane impedances under control Na(+)-transporting and amiloride-inhibited conditions. In all tissues (control, amiloride-blocked, and amiloride-blocked and furosemide-pretreated), PGE(2) caused relatively small (< approximately 3 microA/cm(2)) and rapid (<60 s) maximal increase of chloride current due to activation of a rather large increase of apical membrane conductance that preceded significant activation of Na(+) transport through amiloride-sensitive epithelial Na(+) channels (ENaCs). Apical membrane capacitance was frequency-dependent with a Cole-Cole dielectric dispersion whose relaxation frequency was near 150 Hz. Analysis of the time-dependent changes of the complex frequency-dependent equivalent capacitance of the cells at frequencies >1.5 kHz revealed that the mean 9.8% increase of capacitance caused by PGE(2) was not correlated in time with activation of chloride conductance, but rather correlated with activation of apical membrane Na(+) transport. PMID:11463630
Note: Characterization and test of a high input impedance RF amplifier for series nanowire detector
NASA Astrophysics Data System (ADS)
Wan, Chao; Pei, Yufeng; Jiang, Zhou; Kang, Lin; Wu, Peiheng
2016-09-01
We designed a high input impedance RF amplifier based on Tower Jazz's 0.18 μm SiGe BiCMOS process for series nanowire detector. The characterization of its gain and input impedance with a vector network analyzer is described in detail for its specificity. The actual 15 dB gain should be the measured value subtracts 6 dB, which is easy to be ignored. Its input impedance can be equivalent to 6.7 kΩ ∥ 3.4 pF though fitting the measurement, whose accuracy is verified. The process of measurement provides a good reference to characterize the similar special amplifier with unmatched impedance.
Effect of Influenza-Induced Fever on Human Bioimpedance Values
Marini, Elisabetta; Buffa, Roberto; Contreras, Monica; Magris, Magda; Hidalgo, Glida; Sanchez, Wilmer; Ortiz, Vanessa; Urbaez, Maryluz; Cabras, Stefano; Blaser, Martin J.; Dominguez-Bello, Maria G.
2015-01-01
Background and Aims Bioelectrical impedance analysis (BIA) is a widely used technique to assess body composition and nutritional status. While bioelectrical values are affected by diverse variables, there has been little research on validation of BIA in acute illness, especially to understand prognostic significance. Here we report the use of BIA in acute febrile states induced by influenza. Methods Bioimpedance studies were conducted during an H1N1 influenza A outbreak in Venezuelan Amerindian villages from the Amazonas. Measurements were performed on 52 subjects between 1 and 40 years of age, and 7 children were re-examined after starting Oseltamivir treatment. Bioelectrical Impedance Vector Analysis (BIVA) and permutation tests were applied. Results For the entire sample, febrile individuals showed a tendency toward greater reactance (p=0.058) and phase angle (p=0.037) than afebrile individuals, while resistance and impedance were similar in the two groups. Individuals with repeated measurements showed significant differences in bioimpedance values associated with fever, including increased reactance (p<0.001) and phase angle (p=0.007), and decreased resistance (p=0.007) and impedance (p<0.001). Conclusions There are bioelectrical variations induced by influenza that can be related to dehydration, with lower extracellular to intracellular water ratio in febrile individuals, or a direct thermal effect. Caution is recommended when interpreting bioimpedance results in febrile states. PMID:25915945
MOM3D method of moments code theory manual
NASA Technical Reports Server (NTRS)
Shaeffer, John F.
1992-01-01
MOM3D is a FORTRAN algorithm that solves Maxwell's equations as expressed via the electric field integral equation for the electromagnetic response of open or closed three dimensional surfaces modeled with triangle patches. Two joined triangles (couples) form the vector current unknowns for the surface. Boundary conditions are for perfectly conducting or resistive surfaces. The impedance matrix represents the fundamental electromagnetic interaction of the body with itself. A variety of electromagnetic analysis options are possible once the impedance matrix is computed including backscatter radar cross section (RCS), bistatic RCS, antenna pattern prediction for user specified body voltage excitation ports, RCS image projection showing RCS scattering center locations, surface currents excited on the body as induced by specified plane wave excitation, and near field computation for the electric field on or near the body.
Liu, Xiayi; Yao, Jiafeng; Zhao, Tong; Obara, Hiromichi; Cui, Yahui; Takei, Masahiro
2018-06-01
Contact impedance has an important effect on micro electrical impedance tomography (EIT) sensors compared to conventional macro sensors. In the present work, a complex contact impedance effect ratio ξ is defined to quantitatively evaluate the effect of the contact impedance on the accuracy of the reconstructed images by micro EIT. Quality of the reconstructed image under various ξ is estimated by the phantom simulation to find the optimum algorithm. The generalized vector sampled pattern matching (GVSPM) method reveals the best image quality and the best tolerance to ξ. Moreover, the images of yeast cells sedimentary distribution in a multilayered microchannel are reconstructed by the GVSPM method under various mean magnitudes of contact impedance effect ratio |ξ|. The result shows that the best image quality that has the smallest voltage error U E = 0.581 is achieved with measurement frequency f = 1 MHz and mean magnitude |ξ| = 26. In addition, the reconstructed images of cells distribution become improper while f < 10 kHz and mean value of |ξ| > 2400.
Buffa, R; Mereu, R M; Putzu, P F; Floris, G; Marini, E
2010-12-01
This paper evaluates the nutritional status in patients with mild-moderate and severe Alzheimer's disease (AD) by bioelectrical impedance vector analysis (BIVA). Cross-sectional study. Alzheimer Center, SS. Trinita Hospital, Cagliari, and "Monsignor Angioni" Nursing Home, Quartu Sant'Elena (Cagliari, Italy). 83 free-living patients with mild-moderate Alzheimer's disease (29 men, 54 women), 9 institutionalized women in the severe stage; 468 age-matched controls (202 men, 266 women). Mini Nutritional Assessment (MNA), anthropometric (height, weight, BMI), bioelectrical (R, Xc) and biochemical variables (serum albumin) were assessed. Bioelectrical characteristics were significantly different in the patients with mild-moderate AD with respect to controls, indicating low body cell mass (men, T2= 12.8; women, T2=34.9; p < 0.01). Women with severe AD showed low body cell mass and dehydration with respect to patients with mild-moderate AD (T2=17.1; p < 0.01). The phase angle, R/H and Z/H were significantly correlated (p < 0.05) with MNA (phase: r = 0.31; R/H: r =-0.37; Z/H: r =-0.37) and albumin (phase: r=0.47; R/H: r=-0.36; Z/H: r=-0.36). Alzheimer's disease is characterized by a tendency to malnutrition, present even in the mild-moderate stages, and a tendency to dehydration that appears in the severe stage. The BIVA technique is a promising tool for the screening and monitoring of nutrition and hydration status in Alzheimer's disease.
Dehesa-López, Edgar; Martínez-Felix, Jesús Israel; Ruiz-Ramos, Arturo; Atilano-Carsi, Ximena
2017-04-01
No universally accepted diagnostic criteria for malnutrition are available to date. The aim was to assess the concordance for the diagnosis of hospital malnutrition between the bioelectrical impedance vector analysis (BIVA) and the new definition of malnutrition proposed by the European Society for Clinical Nutrition and Metabolism (ESPEN). A total of 140 adult hospitalized patients were included. The malnutrition risk was assessed by the Nutritional Risk Screening. The ESPEN malnutrition criteria (body mass index (BMI) <18.5 kg/m 2 , weight loss (WL) + low BMI, and WL + low fat free mass index (FFMI) were applied to each patient. The bioelectrical impedance of each patient was measured, and malnutrition was diagnosed using the BIVA method. Diagnostic concordance between the BIVA and the new ESPEN definition was assessed with the Kappa coefficient. The malnutrition prevalence was higher with the BIVA vs ESPEN definition (22.1% vs 13.6%) in the global population and was similar (12.8% vs 12.1%) in the population at risk of malnutrition. The diagnostic performance of the BIVA was acceptable, with higher sensitivity in patients with fluid overload (FO) and more specificity in euvolemic patients. Diagnostic concordance between the BIVA and the ESPEN definition was poor for the global population (kappa = 0.56) and the population at risk of malnutrition (kappa = 0.67) but was acceptable in patients with FO (kappa = 0.78). However, the discordant BIVA+/ESPEN- patients classified as false positives for BIVA showed clinical and body composition data (low FFMI, low phase angle) consistent with malnutrition. According to the clinical and bioelectrical characteristics of the discordant BIVA+/ESPEN- patients, the BIVA could perform better that the new ESPEN definition for the diagnosis of hospital malnutrition, which should be confirmed with other studies. Copyright © 2017 European Society for Clinical Nutrition and Metabolism. Published by Elsevier Ltd. All rights reserved.
Müller, Jakob; Thirion, Christian; Pfaffl, Michael W
2011-01-15
Recombinant viral vectors are widespread tools for transfer of genetic material in various modern biotechnological applications like for example RNA interference (RNAi). However, an accurate and reproducible titer assignment represents the basic step for most downstream applications regarding a precise multiplicity of infection (MOI) adjustment. As necessary scaffold for the studies described in this work we introduce a quantitative real-time PCR (qPCR) based approach for viral particle measurement. Still an implicated problem concerning physiological effects is that the appliance of viral vectors is often attended by toxic effects on the individual target. To determine the critical viral dose leading to cell death we developed an electric cell-substrate impedance sensing (ECIS) based assay. With ECIS technology the impedance change of a current flow through the cell culture medium in an array plate is measured in a non-invasive manner, visualizing effects like cell attachment, cell-cell contacts or proliferation. Here we describe the potential of this online measurement technique in an in vitro model using the porcine ileal epithelial cell line IPI-2I in combination with an adenoviral transfection vector (Ad5-derivate). This approach shows a clear dose-depending toxic effect, as the amount of applied virus highly correlates (p<0.001) with the level of cell death. Thus this assay offers the possibility to discriminate the minimal non-toxic dose of the individual transfection method. In addition this work suggests that the ECIS-device bears the feasibility to transfer this assay to multiple other cytotoxicological questions. Copyright © 2010 Elsevier B.V. All rights reserved.
Modified coaxial wire method for measurement of transfer impedance of beam position monitors
NASA Astrophysics Data System (ADS)
Kumar, Mukesh; Babbar, L. K.; Deo, R. K.; Puntambekar, T. A.; Senecha, V. K.
2018-05-01
The transfer impedance is a very important parameter of a beam position monitor (BPM) which relates its output signal with the beam current. The coaxial wire method is a standard technique to measure transfer impedance of the BPM. The conventional coaxial wire method requires impedance matching between coaxial wire and external circuits (vector network analyzer and associated cables). This paper presents a modified coaxial wire method for bench measurement of the transfer impedance of capacitive pickups like button electrodes and shoe box BPMs. Unlike the conventional coaxial wire method, in the modified coaxial wire method no impedance matching elements have been used between the device under test and the external circuit. The effect of impedance mismatch has been solved mathematically and a new expression of transfer impedance has been derived. The proposed method is verified through simulation of a button electrode BPM using cst studio suite. The new method is also applied to measure transfer impedance of a button electrode BPM developed for insertion devices of Indus-2 and the results are also compared with its simulations. Close agreement between measured and simulation results suggests that the modified coaxial wire setup can be exploited for the measurement of transfer impedance of capacitive BPMs like button electrodes and shoe box BPM.
Comparison of Linear and Nonlinear Processing with Acoustic Vector Sensors
2008-09-01
can write the general form of the time invariant vector sensor planewave response as mik rm mv V e = i , (2.21) where mik rxm xmv V e = i , mik rym...ymv V e = i , and mik rzm zmv V e = i . Using the vector geometry defined, the response of each component is defined by cosxm mV V θ= , sin...velocity values relative to the other by the acoustic impedance, ρc, according to Equation (2.19) , e.g. , mik r mpm pm pm Pv V e V cρ = =i
NASA Astrophysics Data System (ADS)
Alawasa, Khaled Mohammad
Voltage-source converters (VSCs) have gained widespread acceptance in modern power systems. The stability and dynamics of power systems involving these devices have recently become salient issues. In the small-signal sense, the dynamics of VSC-based systems is dictated by its incremental output impedance, which is formed by a combination of 'passive' circuit components and 'active' control elements. Control elements such as control parameters, control loops, and control topologies play a significant role in shaping the impedance profile. Depending on the control schemes and strategies used, VSC-based systems can exhibit different incremental impedance dynamics. As the control elements and dynamics are involved in the impedance structure, the frequency-dependent output impedance might have a negative real-part (i.e., a negative resistance). In the grid-connected mode, the negative resistance degrades the system damping and negatively impacts the stability. In high-voltage networks where high-power VSC-based systems are usually employed and where sub-synchronous dynamics usually exist, integrating large VSC-based systems might reduce the overall damping and results in unstable dynamics. The objectives of this thesis are to (1) investigate and analyze the output impedance properties under different control strategies and control functions, (2) identify and characterize the key contributors to the impedance and sub-synchronous damping profiles, and (3) propose mitigation techniques to minimize and eliminate the negative impact associated with integrating VSC-based systems into power systems. Different VSC configurations are considered in this thesis; in particular, the full-scale and partial-scale topologies (doubly fed-induction generators) are addressed. Additionally, the impedance and system damping profiles are studied under two different control strategies: the standard vector control strategy and the recently-developed power synchronization control strategy. Furthermore, this thesis proposes a simple and robust technique for damping the sub-synchronous resonance in a power system.
Modeling the human body shape in bioimpedance vector measurements.
Kim, Chul-Hyun; Park, Jae-Hyeon; Kim, Hyeoijin; Chung, Sochung; Park, Seung-Hun
2010-01-01
Human body shape, called somatotype, has described physique of humans in health and sports applications, relating anthropometric measurements to fatness, muscularity and linearity in a structured way. Here we propose a new method based on bioelectric impedance vector analysis (BIVA) of R/H and Xc/H to represent the cross-sectional area and the body cell mass in a given surface area (m(2)) respectively. Data from six gymnasts, ten dancers, and five fashion models, groups whose physiques and BMI ranges were distinct from one another, were measured for somatotype and BIVA. The models had highest values of the R/H and gymnasts the lowest. Xc/H was lower in models than in the dancers and gymnasts (p < 0.05). Phase angle was lowest in the models and highest in gymnasts significantly (p < 0.05). Pattern analysis from BIVA corresponded to the calculated anthropometric somatotype supporting the hypothesis that BIA's resistance (R) and reactance (Xc) are meaningful discriminates of body size and function which relate to physique in a purposive way.
Development of Novel Adenoviral Vectors to Overcome Challenges Observed With HAdV-5–based Constructs
Alonso-Padilla, Julio; Papp, Tibor; Kaján, Győző L; Benkő, Mária; Havenga, Menzo; Lemckert, Angelique; Harrach, Balázs; Baker, Andrew H
2016-01-01
Recombinant vectors based on human adenovirus serotype 5 (HAdV-5) have been extensively studied in preclinical models and clinical trials over the past two decades. However, the thorough understanding of the HAdV-5 interaction with human subjects has uncovered major concerns about its product applicability. High vector-associated toxicity and widespread preexisting immunity have been shown to significantly impede the effectiveness of HAdV-5–mediated gene transfer. It is therefore that the in-depth knowledge attained working on HAdV-5 is currently being used to develop alternative vectors. Here, we provide a comprehensive overview of data obtained in recent years disqualifying the HAdV-5 vector for systemic gene delivery as well as novel strategies being pursued to overcome the limitations observed with particular emphasis on the ongoing vectorization efforts to obtain vectors based on alternative serotypes. PMID:26478249
Santillán-Díaz, Cira; Ramírez-Sánchez, Noemi; Espinosa-Morales, Rolando; Orea-Tejeda, Arturo; Llorente, Luis; Rodríguez-Guevara, Gerardo; Castillo-Martínez, Lilia
2018-03-01
Rheumatoid arthritis (RA) patients frequently have changes in their body composition, with a decrease in muscle mass and an increase in fat mass, a syndrome that is termed rheumatoid cachexia (RC). The prevalence of this nutritional alteration is not well known; there is as yet no consensus, seeing as it depends on the methods, techniques, and cutoff points that are used for its diagnosis. The main aim of this study was to identify RC through assessment by bioelectrical impedance vector analysis (BIVA) and its association with metabolic causes, physical function, and the main disease status, among others. The prevalence of RC was identified in those subjects who fell outside the right lower quadrant of the reference curve of RXc graph of BIVA. Clinical, anthropometric, biochemical and physical activity, emotional status, and diet markers were also evaluated. Ninety-four patients were included (92.55% women). The prevalence of RC assessed by BIVA was 21.28%. BIVA-cachexia patients had a lesser value of handgrip strength vs. patients without BIVA-cachexia 10.2 kg (7.2-13.4) vs. 14.7 kg (9.6-19), p = 0.0062. Disability and folic acid with methotrexate consumption are related to BIVA-cachexia ((OR 4.69, 95% CI 1.33, 16.54, p = 0.016) and (OR 0.19, 95%CI 0.058, 0.651, p = 0.008), respectively). BIVA could represent a valuable tool to assess presence of RC. It is important that RA patients have physical therapy to improve their nutritional status.
Optical Vector Near-Field Imaging for the Design of Impedance Matched Optical Antennas and Devices
NASA Astrophysics Data System (ADS)
Olmon, Robert L.
Antennas control and confine electromagnetic energy, transforming free-space propagating modes to localized regions. This is not only true for the traditional classical radio antenna, but also for structures that interact resonantly at frequencies throughout the visible regime, that are on the micro- and nanometer size scales. The investigation of these optical antennas has increased dramatically in recent years. They promise to bring the transformative capabilities of radio antennas to the nanoscale in fields such as plasmonics, photonics, spectroscopy, and microscopy. However, designing optical antennas with desired properties is not straightforward due to different material properties and geometric considerations in the optical regime compared to the RF. New antenna characterization tools and techniques must be developed for the optical frequency range. Here, the optical analogue of the vector network analyzer, based on a scattering-type scanning near-field optical microscope, is described and demonstrated for the investigation of the electric and magnetic properties of optical antennas through their electromagnetic vector near-field. Specifically, bringing this microwave frequency tool to the optical regime enables the study of antenna resonant length scaling, optical frequency electromagnetic parameters including current density and impedance, optical antenna coupling to waveguides and nanoloads, local electric field enhancement, and electromagnetic duality of complementary optical antenna geometries.
Santarelli, Simona; Russo, Veronica; Lalle, Irene; De Berardinis, Benedetta; Navarin, Silvia; Magrini, Laura; Piccoli, Antonio; Codognotto, Marta; Castello, Luigi Maria; Avanzi, Gian Carlo; Villacorta, Humberto; Precht, Bernardo Luiz Campanário; de Araújo Porto, Pilar Barreto; Villacorta, Aline Sterque; Di Somma, Salvatore
2017-06-01
Heart failure is a disease characterized by high prevalence and mortality, and frequent rehospitalizations. The aim of this study is to investigate the prognostic power of combining brain natriuretic peptide (BNP) and congestion status detected by bioelectrical impedance vector analysis (BIVA) in acute heart failure patients. This is an observational, prospective, and a multicentre study. BNP assessment was measured upon hospital arrival, while BIVA analysis was obtained at the time of discharge. Cardiovascular deaths were evaluated at 90 days by a follow up phone call. 292 patients were enrolled. Compared to survivors, BNP was higher in the non-survivors group (mean value 838 vs 515 pg/ml, p < 0.001). At discharge, BIVA shows a statistically significant difference in hydration status between survivors and non-survivors [respectively, hydration index (HI) 85 vs 74, p < 0.001; reactance (Xc) 26.7 vs 37, p < 0.001; resistance (R) 445 vs 503, p < 0.01)]. Discharge BIVA shows a prognostic value in predicting cardiovascular death [HI: area under the curve (AUC) 0.715, 95% confidence interval (95% CI) 0.65-0.76; p < 0.004; Xc: AUC 0.712, 95% CI 0.655-0.76, p < 0.007; R: AUC 0.65, 95% CI 0.29-0.706, p < 0.0247]. The combination of BIVA with BNP gives a greater prognostic power for cardiovascular mortality [combined receiving operating characteristic (ROC): AUC 0.74; 95% CI 0.68-0.79; p < 0.001]. In acute heart failure patients, higher BNP levels upon hospital admission, and congestion detected by BIVA at discharge have a significant predictive value for 90 days cardiovascular mortality. The combined use of admission BNP and BIVA discharge seems to be a useful tool for increasing prognostic power in these patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kopp, Joachim; Liu, Jia; Slatyer, Tracy
Here, we consider dark matter models in which the mass splitting between the dark matter particles and their annihilation products is tiny. Compared to the previously proposed Forbidden Dark Matter scenario, the mass splittings we consider are much smaller, and are allowed to be either positive or negative. To emphasize this modification, we dub our scenario \\Impeded Dark Matter". We also demonstrate that Impeded Dark Matter can be easily realized without requiring tuning of model parameters. For negative mass splitting, we demonstrate that the annihilation cross-section for Impeded Dark Matter depends linearly on the dark matter velocity or may evenmore » be kinematically forbidden, making this scenario almost insensitive to constraints from the cosmic microwave background and from observations of dwarf galaxies. Accordingly, it may be possible for Impeded Dark Matter to yield observable signals in clusters or the Galactic center, with no corresponding signal in dwarfs. Furthermore, for positive mass splitting, we show that the annihilation cross-section is suppressed by the small mass splitting, which helps light dark matter to survive increasingly stringent constraints from indirect searches. As specific realizations for Impeded Dark Matter, we introduce a model of vector dark matter from a hidden SU(2) sector, and a composite dark matter scenario based on a QCD-like dark sector.« less
Kopp, Joachim; Liu, Jia; Slatyer, Tracy; ...
2016-12-12
Here, we consider dark matter models in which the mass splitting between the dark matter particles and their annihilation products is tiny. Compared to the previously proposed Forbidden Dark Matter scenario, the mass splittings we consider are much smaller, and are allowed to be either positive or negative. To emphasize this modification, we dub our scenario \\Impeded Dark Matter". We also demonstrate that Impeded Dark Matter can be easily realized without requiring tuning of model parameters. For negative mass splitting, we demonstrate that the annihilation cross-section for Impeded Dark Matter depends linearly on the dark matter velocity or may evenmore » be kinematically forbidden, making this scenario almost insensitive to constraints from the cosmic microwave background and from observations of dwarf galaxies. Accordingly, it may be possible for Impeded Dark Matter to yield observable signals in clusters or the Galactic center, with no corresponding signal in dwarfs. Furthermore, for positive mass splitting, we show that the annihilation cross-section is suppressed by the small mass splitting, which helps light dark matter to survive increasingly stringent constraints from indirect searches. As specific realizations for Impeded Dark Matter, we introduce a model of vector dark matter from a hidden SU(2) sector, and a composite dark matter scenario based on a QCD-like dark sector.« less
Substructure program for analysis of helicopter vibrations
NASA Technical Reports Server (NTRS)
Sopher, R.
1981-01-01
A substructure vibration analysis which was developed as a design tool for predicting helicopter vibrations is described. The substructure assembly method and the composition of the transformation matrix are analyzed. The procedure for obtaining solutions to the equations of motion is illustrated for the steady-state forced response solution mode, and rotor hub load excitation and impedance are analyzed. Calculation of the mass, damping, and stiffness matrices, as well as the forcing function vectors of physical components resident in the base program code, are discussed in detail. Refinement of the model is achieved by exercising modules which interface with the external program to represent rotor induced variable inflow and fuselage induced variable inflow at the rotor. The calculation of various flow fields is discussed, and base program applications are detailed.
NASA Astrophysics Data System (ADS)
Balleza, M.; Vargas, M.; Kashina, S.; Huerta, M. R.; Delgadillo, I.; Moreno, G.
2017-01-01
Several research groups have proposed the electrical impedance tomography (EIT) in order to analyse lung ventilation. With the use of 16 electrodes, the EIT is capable to obtain a set of transversal section images of thorax. In previous works, we have obtained an alternating signal in terms of impedance corresponding to respiration from EIT images. Then, in order to transform those impedance changes into a measurable volume signal a set of calibration equations has been obtained. However, EIT technique is still expensive to attend outpatients in basics hospitals. For that reason, we propose the use of electrical bioimpedance (EBI) technique to monitor respiration behaviour. The aim of this study was to obtain a set of calibration equations to transform EBI impedance changes determined at 4 different frequencies into a measurable volume signal. In this study a group of 8 healthy males was assessed. From obtained results, a high mathematical adjustment in the group calibrations equations was evidenced. Then, the volume determinations obtained by EBI were compared with those obtained by our gold standard. Therefore, despite EBI does not provide a complete information about impedance vectors of lung compared with EIT, it is possible to monitor the respiration.
Antoni, Giorgia; Marini, Elisabetta; Curreli, Nicoletta; Tuveri, Valerio; Comandini, Ornella; Cabras, Stefano; Gabba, Silvia; Madeddu, Clelia; Crisafulli, Antonio; Rinaldi, Andrea C
2017-01-01
The aim of this study was to determine the energy expenditure of a group of cavers of both genders and different ages and experience during a 10 hour subterranean exploration, using portable metabolimeters. The impact of caving activity on body composition and hydration were also assessed through bioelectrical impedance, and nutritional habits of cavers surveyed. During cave activity, measured total energy expenditure (TEE) was in the range 225-287 kcal/h for women-men (MET = 4.1), respectively; subjects had an energy intake from food in the range 1000-1200 kcal, thus inadequate to restore lost calories. Bayesian statistical analysis estimated the effect of predictive variables on TEE, revealing that experienced subjects had a 5% lower TEE than the less skilled ones and that women required a comparatively larger energy expenditure than men to perform the same task. BIVA (bioelectrical impedance vector analysis) showed that subjects were within the range of normal hydration before and after cave activity, but bioelectrical changes indicated a reduction of extracellular water in men, which might result in hypo-osmolal dehydration in the case of prolonged underground exercise. All these facts should be considered when planning cave explorations, preparing training programs for subjects practising caving, and optimizing a diet for cavers. Further, information gathered through this study could be of value to reduce accidents in caves related to increase in fatigue.
[Bioimpedometry and its utilization in dialysis therapy].
Lopot, František
2016-01-01
Measurement of living tissue impedance - bioimpedometry - started to be used in medicine some 50 years ago, first exclusively for estimation of extracellular and intracellular compartment volumes. Its most simple single frequency (50 kHz) version works directly with the measured impedance vector. Technically more sophisticated versions convert the measured impedance in values of volumes of different compartments of body fluids and calculate also principal markers of nutritional status (lean body mass, adipose tissue mass). The latest version specifically developed for application in dialysis patients includes body composition modelling and provides even absolute value of overhydration (excess fluid). Still in experimental phase is the bioimpedance exploitation for more precise estimation of residual glomerular filtration. Not yet standardized is also segmental bioimpedance measurement which should enable separate assessment of hydration status of the trunk segment and ultrafiltration capacity of peritoneum in peritoneal dialysis patients.Key words: assessment - bioimpedance - excess fluid - fluid status - glomerular filtration - haemodialysis - nutritional status - peritoneal dialysis.
EPG waveforms of blue green sharpshooter: impedance and voltage level effects on stylet probing
USDA-ARS?s Scientific Manuscript database
Blue-green sharpshooter (BGSS), Graphocephala atropunctata, is a native California vector of Xylella fastidiosa (Xf) a foregut-borne bacterium that is the causal agent of Pierce’s disease in grapevines. A 3rd-generation, AC-DC electropenetrograph (EPG) was used to record probing behaviors of adult B...
Park, Andrew W; Cleveland, Christopher A; Dallas, Tad A; Corn, Joseph L
2016-06-01
Although many parasites are transmitted between hosts by a suite of arthropod vectors, the impact of vector biodiversity on parasite transmission is poorly understood. Positive relationships between host infection prevalence and vector species richness (SR) may operate through multiple mechanisms, including (i) increased vector abundance, (ii) a sampling effect in which species of high vectorial capacity are more likely to occur in species-rich communities, and (iii) functional diversity whereby communities comprised species with distinct phenologies may extend the duration of seasonal transmission. Teasing such mechanisms apart is impeded by a lack of appropriate data, yet could highlight a neglected role for functional diversity in parasite transmission. We used statistical modelling of extensive host, vector and microparasite data to test the hypothesis that functional diversity leading to longer seasonal transmission explained variable levels of disease in a wildlife population. We additionally developed a simple transmission model to guide our expectation of how an increased transmission season translates to infection prevalence. Our study demonstrates that vector SR is associated with increased levels of disease reporting, but not via increases in vector abundance or via a sampling effect. Rather, the relationship operates by extending the length of seasonal transmission, in line with theoretical predictions.
Santarelli, Simona; Russo, Veronica; Lalle, Irene; De Berardinis, Benedetta; Vetrone, Francesco; Magrini, Laura; Di Stasio, Enrico; Piccoli, Antonio; Codognotto, Marta; Mion, Monica M; Castello, Luigi M; Avanzi, Gian Carlo; Di Somma, Salvatore
2017-06-01
The objective of this study was to investigate the prognostic role of quantitative reduction of congestion during hospitalization assessed by Bioelectrical Impedance Vector Analysis (BIVA) serial evaluations in patients admitted for acute heart failure (AHF). AHF is a frequent reason for patients to be admitted. Exacerbation of chronic heart failure is linked with a progressive worsening of the disease with increased incidence of death. Fluid overload is the main mechanism underlying acute decompensation in these patients. BIVA is a validated technique able to quantify fluid overload. a prospective, multicentre, observational study in AHF and no AHF patients in three Emergency Departments centres in Italy. Clinical data and BIVA evaluations were performed at admission (t0) and discharge (tdis). A follow-up phone call was carried out at 90 days. Three hundred and thirty-six patients were enrolled (221 AHF and 115 no AHF patients). We found that clinical signs showed the most powerful prognostic relevance. In particular the presence of rales and lower limb oedema at tdis were linked with events relapse at 90 days. At t0, congestion detected by BIVA was observed only in the AHF group, and significantly decreased at tdis. An increase of resistance variation (dR/H) >11 Ω/m during hospitalization was associated with survival. BIVA showed significant results in predicting total events, both at t0 (area under the curve (AUC) 0.56, p<0.04) and at tdis (AUC 0.57, p<0.03). When combined with clinical signs, BIVA showed a very good predictive value for cardiovascular events at 90 days (AUC 0.97, p<0.0001). In AHF patients, an accurate physical examination evaluating the presence of rales and lower limbs oedema remains the cornerstone in the management of patients with AHF. A congestion reduction, obtained as a consequence of therapies and detected through BIVA analysis, with an increase of dR/H >11 Ω/m during hospitalization seems to be associated with increased 90 day survival in patients admitted for AHF.
Demographic effects of deltamethrin resistance in the Chagas disease vector Triatoma infestans.
Germano, M D; Picollo, M I
2016-12-01
Triatoma infestans (Heteroptera: Reduviidae) Klug is the main vector of Chagas disease in Latin America. Resistance to deltamethrin was reported in Argentina and recently associated with reproductive and longevity trade-offs. The objectives of the present study were to describe the demographic consequences of deltamethrin resistance in T. infestans and to establish possible target stages for chemical control in susceptible and resistant colonies. A stage-classified matrix model was constructed based on the average stage length for susceptible, resistant and reciprocal matings' progeny. The differences between colonies were analysed by prospective and retrospective analysis. The life table parameters indicated reduced fecundity, fertility and population growth in resistant insects. The retrospective analysis suggested the latter was associated with lower reproductive output and increased fifth-instar nymph stage length. The prospective analysis suggested that the adult stage should be the main target for insecticide control. Although, fifth-instar nymphs should also be targeted when resistance has been detected. The presented results show demographic effects of deltamethrin resistance in T. infestans. While the older stages could be the main targets for chemical control, this approach is impeded by their higher tolerance to insecticides. It is concluded that the different mode of action insecticides would be more effective than a dose increase for the control of deltamethrin-resistant T. infestans. © 2016 The Royal Entomological Society.
A bioluminescent imaging mouse model for Marburg virus based on a pseudovirus system.
Zhang, Li; Li, Qianqian; Liu, Qiang; Huang, Weijin; Nie, Jianhui; Wang, Youchun
2017-08-03
Marburg virus (MARV) can cause lethal hemorrhagic fever in humans. Handling of MARV is restricted to high-containment biosafety level 4 (BSL-4) facilities, which greatly impedes research into this virus. In this study, a high titer of MARV pseudovirus was generated through optimization of the HIV backbone vectors, the ratio of backbone vector to MARV glycoprotein expression vector, and the transfection reagents. An in vitro neutralization assay and an in vivo bioluminescent imaging mouse model for MARV were developed based on the pseudovirus. Protective serum against MARV was successfully induced in guinea pigs, which showed high neutralization activity in vitro and could also protect Balb/c mice from MARV pseudovirus infection in vivo. This system could be a convenient tool to enable the evaluation of vaccines and therapeutic drugs against MARV in non-BSL-4 laboratories.
Antoni, Giorgia; Marini, Elisabetta; Curreli, Nicoletta; Tuveri, Valerio; Comandini, Ornella; Cabras, Stefano; Gabba, Silvia; Madeddu, Clelia; Crisafulli, Antonio
2017-01-01
The aim of this study was to determine the energy expenditure of a group of cavers of both genders and different ages and experience during a 10 hour subterranean exploration, using portable metabolimeters. The impact of caving activity on body composition and hydration were also assessed through bioelectrical impedance, and nutritional habits of cavers surveyed. During cave activity, measured total energy expenditure (TEE) was in the range 225–287 kcal/h for women-men (MET = 4.1), respectively; subjects had an energy intake from food in the range 1000–1200 kcal, thus inadequate to restore lost calories. Bayesian statistical analysis estimated the effect of predictive variables on TEE, revealing that experienced subjects had a 5% lower TEE than the less skilled ones and that women required a comparatively larger energy expenditure than men to perform the same task. BIVA (bioelectrical impedance vector analysis) showed that subjects were within the range of normal hydration before and after cave activity, but bioelectrical changes indicated a reduction of extracellular water in men, which might result in hypo-osmolal dehydration in the case of prolonged underground exercise. All these facts should be considered when planning cave explorations, preparing training programs for subjects practising caving, and optimizing a diet for cavers. Further, information gathered through this study could be of value to reduce accidents in caves related to increase in fatigue. PMID:28158208
USDA-ARS?s Scientific Manuscript database
Salmonella colonization of food animals is a concern for animal health and public health as a food safety risk. Various obstacles impede the effort to reduce asymptomatic Salmonella carriage in food animals, including the existence of numerous serovars and the ubiquitous nature of Salmonella. To d...
Impedance of curved rectangular spiral coils around a conductive cylinder
NASA Astrophysics Data System (ADS)
Burke, S. K.; Ditchburn, R. J.; Theodoulidis, T. P.
2008-07-01
Eddy-current induction due to a thin conformable coil wrapped around a long conductive cylinder is examined using a second-order vector potential formalism. Compact closed-form expressions are derived for the self- and mutual impedances of curved rectangular spiral coils (i) in free space and (ii) when wrapped around the surface of the cylindrical rod. The validity of these expressions was tested against the results of a systematic series of experiments using a cylindrical Al-alloy rod and conformable coils manufactured using flexible printed-circuit-board technology. The theoretical expressions were in very good agreement with the experimental measurements. The significance of the results for eddy-current nondestructive inspection using flexible coils and flexible coil arrays is discussed.
Korenberg, E I; Nefedova, V V; Kovalevsky, Yu V; Sorokina, Yu V; Gorelova, N B
2015-01-01
Based on the analysis of own and literature data, it is concluded that the following ma- in permanent system of ecologicalarasitological factors prevents the effective vector functions of the tick I. persulcatus in transmission of B. microti: lack of distinct nymphs' anthropophily; small spontaneous invasion of hungry adults; a duration of the parasitic phase in humans is insufficient to complete the sporogonic development, because victims interrupt the phase. Therefore, not excluding the possibility of sporadic babesiosis disea- ses, it can be stated that within the boundaries of a vast territory, where the taiga tick is the only potential source of infection for humans, the B. microti infection has not, and will not reach significant values in infectious pathology.
Heavens, Kristen R; Charkoudian, Nisha; O'Brien, Catherine; Kenefick, Robert W; Cheuvront, Samuel N
2016-03-01
Few dehydration assessment measures provide accurate information; most are based on reference change values and very few are diagnostically accurate from a single observation or measure. Bioelectrical impedance may lack the precision to detect common forms of dehydration in healthy individuals. Limitations in bioimpedance may be addressed by a unique resistance-reactance (RXc)-score graph method, which transforms vector components into z scores for use with any impedance analyzer in any population. We tested whether the RXc-score graph method provides accurate single or serial assessments of dehydration when compared with gold-standard measures of total body water by using stable isotope dilution (deuterium oxide) combined with body-weight changes. We retrospectively analyzed data from a previous study in which 9 healthy young men participated in 3 trials: euhydration (EUH), extracellular dehydration (ED; via a diuretic), and intracellular dehydration (ID; via exercise in the heat). Participants lost 4-5% of their body weight during the dehydration trials; volume loss was similar between trials (ID compared with ED group: 3.5 ± 0.8 compared with 3.0 ± 0.6 L; P > 0.05). Despite significant losses of body water, most RXc vector scores for ED and ID groups were classified as "normal" (within the 75% population tolerance ellipse). However, directional displacement of vectors was consistent with loss of volume in both ED and ID conditions compared with the EUH condition and tended to be longer in ED than in ID conditions (P = 0.054). We conclude that, whereas individual RXc-score graph values do not provide accurate detection of dehydration from single measurements, directional changes in vector values from serial measurements are consistent with fluid loss for both ED and ID conditions. The RXc-score graph method may therefore alert clinicians to changes in hydration state, which may bolster the interpretation of other recognized change measures of hydration. © 2016 American Society for Nutrition.
I-cored Coil Probe Located Above a Conductive Plate with a Surface Hole
NASA Astrophysics Data System (ADS)
Tytko, Grzegorz; Dziczkowski, Leszek
2018-02-01
This work presents an axially symmetric mathematical model of an I-cored coil placed over a two-layered conductive material with a cylindrical surface hole. The problem was divided into regions for which the magnetic vector potential of a filamentary coil was established applying the truncated region eigenfunction expansion method. Then the final formula was developed to calculate impedance changes for a cylindrical coil with reference to both the air and to a material with no hole. The influence of a surface flaw in the conductive material on the components of coil impedance was examined. Calculations were made in Matlab for a hole with various radii and the results thereof were verified with the finite element method in COMSOL Multiphysics package. Very good consistency was achieved in all cases.
Calibration Procedure for Measuring S-Parameters in Balun Applications on 150-ohm High-Speed Cables
NASA Technical Reports Server (NTRS)
Theofylaktos, Onoufrios; Warner, Joseph D.
2012-01-01
In the radiofrequency (RF) world, in order to characterize cables that do not conform to the typical 50-omega impedance, a time domain reflectometer (TDR) would probably be the simplest and quickest tool to attain this goal. In the real world, not every engineer has a TDR at their disposal; however, they most likely have a network analyzer available. Given a generic 50-omega vector network analyzer (VNA), we would like to make S-parameter measurements for non-50-omega devices (DUTs). For that, we utilize RF balanced/unbalanced transformers (called baluns for short), which are primarily used to match the impedance between the two VNA ports and the DUT's input and output ports, for the two-port S-parameter measurements.
Current strategies and successes in engaging women in vector control: a systematic review
Gunn, Jayleen K L; Ernst, Kacey C; Center, Katherine E; Bischoff, Kristi; Nuñez, Annabelle V; Huynh, Megan; Okello, Amanda; Hayden, Mary H
2018-01-01
Introduction Vector-borne diseases (VBDs) cause significant mortality and morbidity in low-income and middle-income countries and present a risk to high-income countries. Vector control programmes may confront social and cultural norms that impede their execution. Anecdotal evidence suggests that incorporating women in the design, delivery and adoption of health interventions increases acceptance and compliance. A better understanding of programmes that have attempted to increase women’s involvement in vector control could help shape best practices. The objective of this systematic review was to assess and critically summarise evidence regarding the effectiveness of women participating in vector control. Methods Seven databases were searched from inception to 21 December 2015. Two investigators independently reviewed all titles and abstracts for relevant articles. Grey literature was searched by assessing websites that focus on international development and vector control. Results In total, 23 articles representing 17 unique studies were included in this review. Studies discussed the involvement of women in the control of vectors for malaria (n=10), dengue (n=8), human African trypanosomiasis (n=3), schistosomiasis (n=1) and a combination (malaria and schistosomiasis, n=1). Seven programmes were found in the grey literature or through personal communications. Available literature indicates that women can be successfully engaged in vector control programmes and, when given the opportunity, they can create and sustain businesses that aim to decrease the burden of VBDs in their communities. Conclusion This systematic review demonstrated that women can be successfully engaged in vector control programmes at the community level. However, rigorous comparative effectiveness studies need to be conducted. PMID:29515913
Rock deformation equations and application to the study on slantingly installed disc cutter
NASA Astrophysics Data System (ADS)
Zhang, Zhao-Huang; Meng, Liang; Sun, Fei
2014-08-01
At present the mechanical model of the interaction between a disc cutter and rock mainly concerns indentation experiment, linear cutting experiment and tunnel boring machine (TBM) on-site data. This is not in line with the actual rock-breaking movement of the disc cutter and impedes to some extent the research on the rock-breaking mechanism, wear mechanism and design theory. Therefore, our study focuses on the interaction between the slantingly installed disc cutter and rock, developing a model in accordance with the actual rock-breaking movement. Displacement equations are established through an analysis of the velocity vector at the rock-breaking point of the disc cutter blade; the functional relationship between the displacement parameters at the rock-breaking point and its rectangular coordinates is established through an analysis of micro-displacement vectors at the rock-breaking point, thus leading to the geometric equations of rock deformation caused by the slantingly installed disc cutter. Considering the basically linear relationship between the cutting force of disc cutters and the rock deformation before and after the leap break of rock, we express the constitutive relations of rock deformation as generalized Hooke's law and analyze the effect of the slanting installation angle of disc cutters on the rock-breaking force. This will, as we hope, make groundbreaking contributions to the development of the design theory and installation practice of TBM.
Single cell array impedance analysis in a microfluidic device
NASA Astrophysics Data System (ADS)
Altinagac, Emre; Taskin, Selen; Kizil, Huseyin
2016-10-01
Impedance analysis of single cells is presented in this paper. Following the separation of a target cell type by dielectrophoresis in our previous work, this paper focuses on capturing the cells as a single array and performing impedance analysis to point out the signature difference between each cell type. Lab-on-a-chip devices having a titanium interdigitated electrode layer on a glass substrate and a PDMS microchannel are fabricated to capture each cell in a single form and perform impedance analysis. HCT116 (homosapiens colon colorectal carcin) and HEK293 (human embryonic kidney) cells are used in our experiments.
Disorders of nutritional status in sepsis – facts and myths
Wachowska, Ewelina; Słotwiński, Robert
2017-01-01
The problem of diagnosing nutritional status disorders in septic patients remains unresolved. This is associated with the necessity of the introduction of newer and newer methods of assessing nutritional status, often requiring precise and expensive equipment as well as employment of professionals in this field in hospital wards, primarily including intensive care units (ICU). Methods that have been applied thus far for assessing nutritional status, also used in severely ill septic patients, have little impact on improving treatment results. This is due to the high dynamics of changes in nutritional status in these patients, healing process variability in individual patients, and the “mismatch” of methods for assessing nutritional status in relation to the patient’s clinical status. The diagnostic value of the traditional methods of assessing nutritional status, i.e. anthropometric analysis and selected laboratory tests, as markers of nutritional status disorders in septic patients, is still debatable. There is still no precise method that could become the “gold standard” allowing for early identification of malnutrition in these group of patients. Phase angle, bioelectrical impedance vector analysis (BIVA), and the “illness marker”, obtained directly from the resistance, reactance, and impedance, can be used as prognostic or nutritional indices in severely ill septic patients, but the intensity of research on this subject needs to be increased. Detailed assessment of nutritional status should include tests of selected inflammation markers (including TLC, HMGB1, IL-6, IL-10, IL-1ra, sTNFRI). PMID:28702094
Disorders of nutritional status in sepsis - facts and myths.
Kosałka, Katarzyna; Wachowska, Ewelina; Słotwiński, Robert
2017-01-01
The problem of diagnosing nutritional status disorders in septic patients remains unresolved. This is associated with the necessity of the introduction of newer and newer methods of assessing nutritional status, often requiring precise and expensive equipment as well as employment of professionals in this field in hospital wards, primarily including intensive care units (ICU). Methods that have been applied thus far for assessing nutritional status, also used in severely ill septic patients, have little impact on improving treatment results. This is due to the high dynamics of changes in nutritional status in these patients, healing process variability in individual patients, and the "mismatch" of methods for assessing nutritional status in relation to the patient's clinical status. The diagnostic value of the traditional methods of assessing nutritional status, i.e. anthropometric analysis and selected laboratory tests, as markers of nutritional status disorders in septic patients, is still debatable. There is still no precise method that could become the "gold standard" allowing for early identification of malnutrition in these group of patients. Phase angle, bioelectrical impedance vector analysis (BIVA), and the "illness marker", obtained directly from the resistance, reactance, and impedance, can be used as prognostic or nutritional indices in severely ill septic patients, but the intensity of research on this subject needs to be increased. Detailed assessment of nutritional status should include tests of selected inflammation markers (including TLC, HMGB1, IL-6, IL-10, IL-1ra, sTNFRI).
Thermal stress characterization using the electro-mechanical impedance method
NASA Astrophysics Data System (ADS)
Zhu, Xuan; Lanza di Scalea, Francesco; Fateh, Mahmood
2017-04-01
This study examines the potential of the Electro-Mechanical Impedance (EMI) method to provide an estimation of the developed thermal stress in constrained bar-like structures. This non-invasive method features the easiness of implementation and interpretation, while it is notoriously known for being vulnerable to environmental variability. A comprehensive analytical model is proposed to relate the measured electric admittance signatures of the PZT element to temperature and uniaxial stress applied to the underlying structure. The model results compare favorably to the experimental ones, where the sensitivities of features extracted from the admittance signatures to the varying stress levels and temperatures are determined. Two temperature compensation frameworks are proposed to characterize the thermal stress states: (a) a regression model is established based on temperature-only tests, and the residuals from the thermal stress tests are then used to isolate the stress measurand; (b) the temperature-only tests are decomposed by Principle Components Analysis (PCA) and the feature vectors of the thermal stress tests are reconstructed after removal of the temperaturesensitive components. For both methods, the features were selected based on their performance in Receiver Operating Characteristic (ROC) curves. Experimental results on the Continuous Welded Rails (CWR) are shown to demonstrate the effectiveness of these temperature compensation methods.
Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review
Bera, Tushar Kanti
2014-01-01
Under the alternating electrical excitation, biological tissues produce a complex electrical impedance which depends on tissue composition, structures, health status, and applied signal frequency, and hence the bioelectrical impedance methods can be utilized for noninvasive tissue characterization. As the impedance responses of these tissue parameters vary with frequencies of the applied signal, the impedance analysis conducted over a wide frequency band provides more information about the tissue interiors which help us to better understand the biological tissues anatomy, physiology, and pathology. Over past few decades, a number of impedance based noninvasive tissue characterization techniques such as bioelectrical impedance analysis (BIA), electrical impedance spectroscopy (EIS), electrical impedance plethysmography (IPG), impedance cardiography (ICG), and electrical impedance tomography (EIT) have been proposed and a lot of research works have been conducted on these methods for noninvasive tissue characterization and disease diagnosis. In this paper BIA, EIS, IPG, ICG, and EIT techniques and their applications in different fields have been reviewed and technical perspective of these impedance methods has been presented. The working principles, applications, merits, and demerits of these methods has been discussed in detail along with their other technical issues followed by present status and future trends. PMID:27006932
One-port portable SAW sensor system
NASA Astrophysics Data System (ADS)
Hoa Nguyen, Vu; Peters, Oliver; Schnakenberg, Uwe
2018-01-01
A portable device using the SAW-based impedance sensor type based on one interdigital transducer simultaneously as SAW generator and sensor element (1-port approach) is introduced. As a novelty, the so far required expensive vector network analyzer (VNA) is replaced by a hand-held device to measure the impedance spectrum of the SAW sensor by RF-gain-phase meters. Hence, some of the best features from the conventional oscillator and VNA approaches are combined to develop a low-cost and self-contained measurement system, including signal in- and output ability for real-time measurements. The pivotal aspect of the portable system is the transfer of the sophisticated high frequency approach into a quasi-static one. This enables the use of simple lumped electronics without the need of impedance matching circuits. Proof-of-concept was carried out by measuring conductivities of phosphate-buffered solutions and viscosities of glycerin. Sensitivities for temperature of 0.3%/°C, viscosity of 10.1% (mPa s)-1 and conductivity of 0.5% (S cm)-1 have been determined, respectively, which are competitive results compared to the benchmark approaches.
Entrance and Exit CSR Impedance for Non-Ultrarelativistic Beam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Rui; Tsai, Cheng Ying
2017-05-01
For a high-brightness electron beam being transported through beamlines involving bending systems, the coherent synchrotron radiation (CSR) and longitudinal space charge (LSC) interaction could often cause microbunching instability. The semi-analytical Vlasov solver for microbunching gain* depends on the impedances for the relevant collective effects. The existing results for CSR impedances are usually obtained for the ultrarelativistic limit. To extend the microbunching analysis to cases of low energies, such as the case of an ERL merger, or to density modulations at extremely small wavelength, it is necessary to extend the impedance analysis to the non-ultrarelativistic regime. In this study, we presentmore » the impedance analysis for the transient CSR interaction in the non-ultrarelativistic regime, for transients including both entrance to and exit from a magnetic dipole. These impedance results will be compared to their ultra-relativistic counterparts**, and the corresponding wakefield obtained from the impedance for low-energy beams will be compared with the existing results of transient CSR wakefield for general beam energies***.« less
García-Sánchez, Tomás; Bragós, Ramon; Mir, Lluis M
2018-06-07
This paper reports the comparative analysis, by means of electric impedance spectroscopy measurements, of three different cell lines subjected to electroporative pulses. The multifrequency information is recorded simultaneously at 21 frequency values in the range between 5 kHz and 1.3 MHz using a multisine based measuring approach. The analysis of the pre-electroporation impedance spectra shows how the system is able to detect differences and similarities between the cell lines under analysis. Particularly, a good agreement is found between the average cell diameter and the characteristic frequency (the frequency corresponding to a maximum in the imaginary part of the impedance). The measurements performed during electroporation at three different electric field intensities show how the impedance spectra changes dynamically between the consecutive pulses of a train of 8,100 µs pulses delivered at 1 Hz repetition rate. There are clear differences between the changes in the impedance measured at low and high frequency. The multifrequency information has been fitted to an electrical equivalent model in order to understand the different contributions in the observed impedance changes (mainly separate between membrane permeabilization and the conductivity changes in the extracellular medium). Finally, a ratio of the low and high frequency impedance information is used to estimate the accumulated impedance decay and to compare it to the internalization of a fluorescent permeabilization reporter. The comparison between both techniques at the three electroporation electric field intensities assayed confirms the ability of impedance measurements to detect in a precise way the level of membrane permeabilization. Additionally, this study demonstrates how the real time information obtained thanks to impedance measurements can provide a more precise quantification of the membrane permeabilization extent. Copyright © 2018 Elsevier B.V. All rights reserved.
Tasharrofi, Nooshin; Kouhkan, Fatemeh; Soleimani, Masoud; Soheili, Zahra-Soheila; Atyabi, Fatemeh; Akbari Javar, Hamid; Abedin Dorkoosh, Farid
2017-02-25
The purpose of this study is designing non-viral gene delivery vectors for transfection of the primary human retinal pigment epithelial cells (RPE). In the design process of gene delivery vectors, considering physicochemical properties of vectors alone does not seem to be enough since they interact with constituents of the surrounding environment and hence gain new characteristics. Moreover, due to these interactions, their cargo can be released untimely or undergo degradation before reaching to the target cells. Further, the characteristics of cells itself can also influence the transfection efficacy. For example, the non-dividing property of RPE cells can impede the transfection efficiency which in most studies was ignored by using immortal cell lines. In this study, vectors with different characteristics differing in mixing orders of pDNA, PEI polymer, and PLGA/PEI or PLGA nanoparticles were prepared and characterized. Then, their characteristics and efficacy in gene delivery to RPE cells in the presence of vitreous or fetal bovine serum (FBS) were evaluated. All formulations showed no cytotoxicity and were able to protect pDNA from premature release and degradation in extracellular media. Also, the adsorption of vitreous or serum proteins onto the surface of vectors changed their properties and hence cellular uptake and transfection efficacy. Copyright © 2016 Elsevier B.V. All rights reserved.
Ecology of Anopheles darlingi Root with respect to vector importance: a review
2011-01-01
Anopheles darlingi is one of the most important malaria vectors in the Americas. In this era of new tools and strategies for malaria and vector control it is essential to have knowledge on the ecology and behavior of vectors in order to evaluate appropriateness and impact of control measures. This paper aims to provide information on the importance, ecology and behavior of An. darlingi. It reviews publications that addressed ecological and behavioral aspects that are important to understand the role and importance of An. darlingi in the transmission of malaria throughout its area of distribution. The results show that Anopheles darlingi is especially important for malaria transmission in the Amazon region. Although numerous studies exist, many aspects determining the vectorial capacity of An. darlingi, i.e. its relation to seasons and environmental conditions, its gonotrophic cycle and longevity, and its feeding behavior and biting preferences, are still unknown. The vector shows a high degree of variability in behavioral traits. This makes it difficult to predict the impact of ongoing changes in the environment on the mosquito populations. Recent studies indicate a good ability of An. darlingi to adapt to environments modified by human development. This allows the vector to establish populations in areas where it previously did not exist or had been controlled to date. The behavioral variability of the vector, its adaptability, and our limited knowledge of these impede the establishment of effective control strategies. Increasing our knowledge of An. darlingi is necessary. PMID:21923902
He, Wen-Bo; Li, Jie; Liu, Shu-Sheng
2015-01-08
Plant viruses interact with their insect vectors directly and indirectly via host plants, and this tripartite interaction may produce fitness benefits to both the vectors and the viruses. Our previous studies show that the Middle East-Asia Minor 1 (MEAM1) species of the whitefly Bemisia tabaci complex improved its performance on tobacco plants infected by the Tomato yellow leaf curl China virus (TYLCCNV), which it transmits, although virus infection of the whitefly per se reduced its performance. Here, we use electrical penetration graph recording to investigate the direct and indirect effects of TYLCCNV on the feeding behaviour of MEAM1. When feeding on either cotton, a non-host of TYLCCNV, or uninfected tobacco, a host of TYLCCNV, virus-infection of the whiteflies impeded their feeding. Interestingly, when viruliferous whiteflies fed on virus-infected tobacco, their feeding activities were no longer negatively affected; instead, the virus promoted whitefly behaviour related to rapid and effective sap ingestion. Our findings show differential profiles of direct and indirect modification of vector feeding behaviour by a plant virus, and help to unravel the behavioural mechanisms underlying a mutualistic relationship between an insect vector and a plant virus that also has features reminiscent of an insect pathogen.
RNA Interference in Infectious Tropical Diseases
Hong, Young S.
2008-01-01
Introduction of double-stranded RNA (dsRNA) into some cells or organisms results in degradation of its homologous mRNA, a process called RNA interference (RNAi). The dsRNAs are processed into short interfering RNAs (siRNAs) that subsequently bind to the RNA-induced silencing complex (RISC), causing degradation of target mRNAs. Because of this sequence-specific ability to silence target genes, RNAi has been extensively used to study gene functions and has the potential to control disease pathogens or vectors. With this promise of RNAi to control pathogens and vectors, this paper reviews the current status of RNAi in protozoans, animal parasitic helminths and disease-transmitting vectors, such as insects. Many pathogens and vectors cause severe parasitic diseases in tropical regions and it is difficult to control once the host has been invaded. Intracellularly, RNAi can be highly effective in impeding parasitic development and proliferation within the host. To fully realize its potential as a means to control tropical diseases, appropriate delivery methods for RNAi should be developed, and possible off-target effects should be minimized for specific gene suppression. RNAi can also be utilized to reduce vector competence to interfere with disease transmission, as genes critical for pathogenesis of tropical diseases are knockdowned via RNAi. PMID:18344671
He, Wen-Bo; Li, Jie; Liu, Shu-Sheng
2015-01-01
Plant viruses interact with their insect vectors directly and indirectly via host plants, and this tripartite interaction may produce fitness benefits to both the vectors and the viruses. Our previous studies show that the Middle East-Asia Minor 1 (MEAM1) species of the whitefly Bemisia tabaci complex improved its performance on tobacco plants infected by the Tomato yellow leaf curl China virus (TYLCCNV), which it transmits, although virus infection of the whitefly per se reduced its performance. Here, we use electrical penetration graph recording to investigate the direct and indirect effects of TYLCCNV on the feeding behaviour of MEAM1. When feeding on either cotton, a non-host of TYLCCNV, or uninfected tobacco, a host of TYLCCNV, virus-infection of the whiteflies impeded their feeding. Interestingly, when viruliferous whiteflies fed on virus-infected tobacco, their feeding activities were no longer negatively affected; instead, the virus promoted whitefly behaviour related to rapid and effective sap ingestion. Our findings show differential profiles of direct and indirect modification of vector feeding behaviour by a plant virus, and help to unravel the behavioural mechanisms underlying a mutualistic relationship between an insect vector and a plant virus that also has features reminiscent of an insect pathogen. PMID:25567524
Skin-electrode circuit model for use in optimizing energy transfer in volume conduction systems.
Hackworth, Steven A; Sun, Mingui; Sclabassi, Robert J
2009-01-01
The X-Delta model for through-skin volume conduction systems is introduced and analyzed. This new model has advantages over our previous X model in that it explicitly represents current pathways in the skin. A vector network analyzer is used to take measurements on pig skin to obtain data for use in finding the model's impedance parameters. An optimization method for obtaining this more complex model's parameters is described. Results show the model to accurately represent the impedance behavior of the skin system with error of generally less than one percent. Uses for the model include optimizing energy transfer across the skin in a volume conduction system with appropriate current exposure constraints, and exploring non-linear behavior of the electrode-skin system at moderate voltages (below ten) and frequencies (kilohertz to megahertz).
Bioelectrical impedance analysis for bovine milk: Preliminary results
NASA Astrophysics Data System (ADS)
Bertemes-Filho, P.; Valicheski, R.; Pereira, R. M.; Paterno, A. S.
2010-04-01
This work reports the investigation and analysis of bovine milk quality by using biological impedance measurements using electrical impedance spectroscopy (EIS). The samples were distinguished by a first chemical analysis using Fourier transform midinfrared spectroscopy (FTIR) and flow citometry. A set of milk samples (100ml each) obtained from 17 different cows in lactation with and without mastitis were analyzed with the proposed technique using EIS. The samples were adulterated by adding distilled water and hydrogen peroxide in a controlled manner. FTIR spectroscopy and flow cytometry were performed, and impedance measurements were made in a frequency range from 500Hz up to 1MHz with an implemented EIS system. The system's phase shift was compensated by measuring saline solutions. It was possible to show that the results obtained with the Bioelectrical Impedance Analysis (BIA) technique may detect changes in the milk caused by mastitis and the presence of water and hydrogen peroxide in the bovine milk.
Păunescu, T G; Helman, S I
2001-01-01
Transepithelial electrical impedance analysis provides a sensitive method to evaluate the conductances and capacitances of apical and basolateral plasma membranes of epithelial cells. Impedance analysis is complicated, due not only to the anatomical arrangement of the cells and their paracellular shunt pathways, but also in particular to the existence of audio frequency-dependent capacitances or dispersions. In this paper we explore implications and consequences of anatomically related Maxwell-Wagner and Cole-Cole dielectric dispersions that impose limitations, approximations, and pitfalls of impedance analysis when tissues are studied under widely ranging spontaneous rates of transport, and in particular when apical membrane sodium and chloride channels are activated by adenosine 3',5'-cyclic monophosphate (cAMP) in A6 epithelia. We develop the thesis that capacitive relaxation processes of any origin lead not only to dependence on frequency of the impedance locus, but also to the appearance of depressed semicircles in Nyquist transepithelial impedance plots, regardless of the tightness or leakiness of the paracellular shunt pathways. Frequency dependence of capacitance precludes analysis of data in traditional ways, where capacitance is assumed constant, and is especially important when apical and/or basolateral membranes exhibit one or more dielectric dispersions. PMID:11463629
Uncertainty Analysis of the Grazing Flow Impedance Tube
NASA Technical Reports Server (NTRS)
Brown, Martha C.; Jones, Michael G.; Watson, Willie R.
2012-01-01
This paper outlines a methodology to identify the measurement uncertainty of NASA Langley s Grazing Flow Impedance Tube (GFIT) over its operating range, and to identify the parameters that most significantly contribute to the acoustic impedance prediction. Two acoustic liners are used for this study. The first is a single-layer, perforate-over-honeycomb liner that is nonlinear with respect to sound pressure level. The second consists of a wire-mesh facesheet and a honeycomb core, and is linear with respect to sound pressure level. These liners allow for evaluation of the effects of measurement uncertainty on impedances educed with linear and nonlinear liners. In general, the measurement uncertainty is observed to be larger for the nonlinear liners, with the largest uncertainty occurring near anti-resonance. A sensitivity analysis of the aerodynamic parameters (Mach number, static temperature, and static pressure) used in the impedance eduction process is also conducted using a Monte-Carlo approach. This sensitivity analysis demonstrates that the impedance eduction process is virtually insensitive to each of these parameters.
High-Resolution Large-Field-of-View Ultrasound Breast Imager
2012-06-01
plane waves all having the same wave vector magnitude 0k but propagating in different directions . This observation forms the mathematical basis of the...origin of the object Fourier space and is oriented opposite the propagation direction of the probing plane wave field. Moreover, the 43 radius of...in water. Each element was electrically tuned to match to the 50-Ohm impedance of an RF Amplifier powered by a 4.0 MHz electrical signal from a
Cationic liposome/DNA complexes: from structure to interactions with cellular membranes.
Caracciolo, Giulio; Amenitsch, Heinz
2012-10-01
Gene-based therapeutic approaches are based upon the concept that, if a disease is caused by a mutation in a gene, then adding back the wild-type gene should restore regular function and attenuate the disease phenotype. To deliver the gene of interest, both viral and nonviral vectors are used. Viruses are efficient, but their application is impeded by detrimental side-effects. Among nonviral vectors, cationic liposomes are the most promising candidates for gene delivery. They form stable complexes with polyanionic DNA (lipoplexes). Despite several advantages over viral vectors, the transfection efficiency (TE) of lipoplexes is too low compared with those of engineered viral vectors. This is due to lack of knowledge about the interactions between complexes and cellular components. Rational design of efficient lipoplexes therefore requires deeper comprehension of the interactions between the vector and the DNA as well as the cellular pathways and mechanisms involved. The importance of the lipoplex structure in biological function is revealed in the application of synchrotron small-angle X-ray scattering in combination with functional TE measurements. According to current understanding, the structure of lipoplexes can change upon interaction with cellular membranes and such changes affect the delivery efficiency. Recently, a correlation between the mechanism of gene release from complexes, the structure, and the physical and chemical parameters of the complexes has been established. Studies aimed at correlating structure and activity of lipoplexes are reviewed herein. This is a fundamental step towards rational design of highly efficient lipid gene vectors.
NASA Astrophysics Data System (ADS)
Sharp, Andy; Heath, Jennifer; Peterson, Janet
2008-05-01
Consumer grade bioelectric impedance analysis (BIA) instruments measure the body's impedance at 50 kHz, and yield a quick estimate of percent body fat. The frequency dependence of the impedance gives more information about the current pathway and the response of different tissues. This study explores the impedance response of human tissue at a range of frequencies from 0.2 - 102 kHz using a four probe method and probe locations standard for segmental BIA research of the arm. The data at 50 kHz, for a 21 year old healthy Caucasian male (resistance of 180φ±10 and reactance of 33φ±2) is in agreement with previously reported values [1]. The frequency dependence is not consistent with simple circuit models commonly used in evaluating BIA data, and repeatability of measurements is problematic. This research will contribute to a better understanding of the inherent difficulties in estimating body fat using consumer grade BIA devices. [1] Chumlea, William C., Richard N. Baumgartner, and Alex F. Roche. ``Specific resistivity used to estimate fat-free mass from segmental body measures of bioelectrical impedance.'' Am J Clin Nutr 48 (1998): 7-15.
Time-domain representation of frequency-dependent foundation impedance functions
Safak, E.
2006-01-01
Foundation impedance functions provide a simple means to account for soil-structure interaction (SSI) when studying seismic response of structures. Impedance functions represent the dynamic stiffness of the soil media surrounding the foundation. The fact that impedance functions are frequency dependent makes it difficult to incorporate SSI in standard time-history analysis software. This paper introduces a simple method to convert frequency-dependent impedance functions into time-domain filters. The method is based on the least-squares approximation of impedance functions by ratios of two complex polynomials. Such ratios are equivalent, in the time-domain, to discrete-time recursive filters, which are simple finite-difference equations giving the relationship between foundation forces and displacements. These filters can easily be incorporated into standard time-history analysis programs. Three examples are presented to show the applications of the method.
Magnetic hyperbolic optical metamaterials
Kruk, Sergey S.; Wong, Zi Jing; Pshenay-Severin, Ekaterina; ...
2016-04-13
Strongly anisotropic media where the principal components of electric permittivity or magnetic permeability tensors have opposite signs are termed as hyperbolic media. Such media support propagating electromagnetic waves with extremely large wave vectors exhibiting unique optical properties. However, in all artificial and natural optical materials studied to date, the hyperbolic dispersion originates solely from the electric response. This then restricts material functionality to one polarization of light and inhibits free-space impedance matching. Such restrictions can be overcome in media having components of opposite signs for both electric and magnetic tensors. Here we present the experimental demonstration of the magnetic hyperbolicmore » dispersion in three-dimensional metamaterials. We also measure metamaterial isofrequency contours and reveal the topological phase transition between the elliptic and hyperbolic dispersion. In the hyperbolic regime, we demonstrate the strong enhancement of thermal emission, which becomes directional, coherent and polarized. These findings show the possibilities for realizing efficient impedance-matched hyperbolic media for unpolarized light.« less
A systematic uncertainty analysis for liner impedance eduction technology
NASA Astrophysics Data System (ADS)
Zhou, Lin; Bodén, Hans
2015-11-01
The so-called impedance eduction technology is widely used for obtaining acoustic properties of liners used in aircraft engines. The measurement uncertainties for this technology are still not well understood though it is essential for data quality assessment and model validation. A systematic framework based on multivariate analysis is presented in this paper to provide 95 percent confidence interval uncertainty estimates in the process of impedance eduction. The analysis is made using a single mode straightforward method based on transmission coefficients involving the classic Ingard-Myers boundary condition. The multivariate technique makes it possible to obtain an uncertainty analysis for the possibly correlated real and imaginary parts of the complex quantities. The results show that the errors in impedance results at low frequency mainly depend on the variability of transmission coefficients, while the mean Mach number accuracy is the most important source of error at high frequencies. The effect of Mach numbers used in the wave dispersion equation and in the Ingard-Myers boundary condition has been separated for comparison of the outcome of impedance eduction. A local Mach number based on friction velocity is suggested as a way to reduce the inconsistencies found when estimating impedance using upstream and downstream acoustic excitation.
NASA Astrophysics Data System (ADS)
Liu, Hai-Tao; Wen, Zhi-Yu; Xu, Yi; Shang, Zheng-Guo; Peng, Jin-Lan; Tian, Peng
2017-09-01
In this paper, an integrated microfluidic analysis microsystems with bacterial capture enrichment and in-situ impedance detection was purposed based on microfluidic chips dielectrophoresis technique and electrochemical impedance detection principle. The microsystems include microfluidic chip, main control module, and drive and control module, and signal detection and processing modulet and result display unit. The main control module produce the work sequence of impedance detection system parts and achieve data communication functions, the drive and control circuit generate AC signal which amplitude and frequency adjustable, and it was applied on the foodborne pathogens impedance analysis microsystems to realize the capture enrichment and impedance detection. The signal detection and processing circuit translate the current signal into impendence of bacteria, and transfer to computer, the last detection result is displayed on the computer. The experiment sample was prepared by adding Escherichia coli standard sample into chicken sample solution, and the samples were tested on the dielectrophoresis chip capture enrichment and in-situ impedance detection microsystems with micro-array electrode microfluidic chips. The experiments show that the Escherichia coli detection limit of microsystems is 5 × 104 CFU/mL and the detection time is within 6 min in the optimization of voltage detection 10 V and detection frequency 500 KHz operating conditions. The integrated microfluidic analysis microsystems laid the solid foundation for rapid real-time in-situ detection of bacteria.
Analysis of photoelectron effect on the antenna impedance via Particle-In-Cell simulation
NASA Astrophysics Data System (ADS)
Miyake, Y.; Usui, H.
2008-08-01
We present photoelectron effects on the impedance of electric field antennas used for plasma wave investigations. To illustrate the photoelectron effects, we applied electromagnetic Particle-In-Cell simulation to the self-consistent antenna impedance analysis. We confirmed the formation of a dense photoelectron region around the sunlit surfaces of the antenna and the spacecraft. The dense photoelectrons enhance the real part, and decrease the absolute value of the imaginary part, of antenna impedance at low frequencies. We also showed that the antenna conductance can be analytically calculated from simulation results of the electron current flowing into or out of the antenna. The antenna impedance in the photoelectron environment is represented by a parallel equivalent circuit consisting of a capacitance and a resistance, which is consistent with empirical knowledge. The results also imply that the impedance varies with the spin of the spacecraft, which causes the variation of the photoelectron density around the antenna.
How to Remedy the η-problem of SUSY GUT hybrid inflation via vector backreaction
NASA Astrophysics Data System (ADS)
Lazarides, George
2012-07-01
It is shown that, in supergravity models of inflation where the gauge kinetic function of a gauge field is modulated by the inflaton, we can obtain a new inflationary attractor solution, in which the roll-over of the inflaton suffers additional impedance due to the vector field backreaction. As a result, directions of the scalar potential which, due to strong Kähler corrections, become too steep and curved to normally support slow-roll inflation can now naturally do so. This solves the infamous η problem of inflation in supergravity and also keeps the spectral index of the curvature perturbation mildly red despite η of order unity. This mechanism is applied to a model of hybrid inflation in supergravity with a generic Kähler potential. The spectral index of the curvature perturbation is found to be 0.97 - 0.98, in excellent agreement with data. The gauge field can act as vector curvaton generating statistical anisotropy in the curvature perturbation. However, this anisotropy could be possibly observable only if the gauge coupling constant is unnaturally small.
Nguyen, N Q; Holloway, R H; Smout, A J; Omari, T I
2013-03-01
Automated integrated analysis of impedance and pressure signals has been reported to identify patients at risk of developing dysphagia post fundoplication. This study aimed to investigate this analysis in the evaluation of patients with non-obstructive dysphagia (NOD) and normal manometry (NOD/NM). Combined impedance-manometry was performed in 42 patients (27F : 15M; 56.2 ± 5.1 years) and compared with that of 24 healthy subjects (8F : 16M; 48.2 ± 2.9 years). Both liquid and viscous boluses were tested. MATLAB-based algorithms defined the median intrabolus pressure (IBP), IBP slope, peak pressure (PP), and timing of bolus flow relative to peak pressure (TNadImp-PP). An index of pressure and flow (PFI) in the distal esophagus was derived from these variables. Diagnoses based on conventional manometric assessment: diffuse spasm (n = 5), non-specific motor disorders (n = 19), and normal (n = 11). Patients with achalasia (n = 7) were excluded from automated impedance-manometry (AIM) analysis. Only 2/11 (18%) patients with NOD/NM had evidence of flow abnormality on conventional impedance analysis. Several variables derived by integrated impedance-pressure analysis were significantly different in patients as compared with healthy: higher PNadImp (P < 0.01), IBP (P < 0.01) and IBP slope (P < 0.05), and shorter TNadImp_PP (P = 0.01). The PFI of NOD/NM patients was significantly higher than that in healthy (liquid: 6.7 vs 1.2, P = 0.02; viscous: 27.1 vs 5.7, P < 0.001) and 9/11 NOD/NM patients had abnormal PFI. Overall, the addition of AIM analysis provided diagnoses and/or a plausible explanation in 95% (40/42) of patients who presented with NOD. Compared with conventional pressure-impedance assessment, integrated analysis is more sensitive in detecting subtle abnormalities in esophageal function in patients with NOD and normal manometry. © 2012 Blackwell Publishing Ltd.
Chen, Jian; Xue, Chengcheng; Zhao, Yang; Chen, Deyong; Wu, Min-Hsien; Wang, Junbo
2015-01-01
This article reviews recent developments in microfluidic impedance flow cytometry for high-throughput electrical property characterization of single cells. Four major perspectives of microfluidic impedance flow cytometry for single-cell characterization are included in this review: (1) early developments of microfluidic impedance flow cytometry for single-cell electrical property characterization; (2) microfluidic impedance flow cytometry with enhanced sensitivity; (3) microfluidic impedance and optical flow cytometry for single-cell analysis and (4) integrated point of care system based on microfluidic impedance flow cytometry. We examine the advantages and limitations of each technique and discuss future research opportunities from the perspectives of both technical innovation and clinical applications. PMID:25938973
A PARAMETRIC STUDY OF BCS RF SURFACE IMPEDANCE WITH MAGNETIC FIELD USING THE XIAO CODE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reece, Charles E.; Xiao, Binping
2013-09-01
A recent new analysis of field-dependent BCS rf surface impedance based on moving Cooper pairs has been presented.[1] Using this analysis coded in Mathematica TM, survey calculations have been completed which examine the sensitivities of this surface impedance to variation of the BCS material parameters and temperature. The results present a refined description of the "best theoretical" performance available to potential applications with corresponding materials.
An efficient signal processing tool for impedance-based structural health monitoring
NASA Astrophysics Data System (ADS)
O'Brien, Megan K.; Taylor, Stuart G.; Farinholt, Kevin M.; Park, Gyuhae; Farrar, Charles R.
2009-03-01
Various experimental studies have demonstrated that an impedance-based approach to structural health monitoring can be an effective means of damage detection. Using the self-sensing and active-sensing capabilities of piezoelectric materials, the electromechanical impedance response can be monitored to provide a qualitative indication of the overall health of a structure. Although impedance analyzers are commonly used to collect such data, they are bulky and impractical for long-term field implementation, so a smaller and more portable device is desired. However, impedance measurements often contain a sizeable number of data points, and a smaller device may not possess enough memory to store the required information, particularly for real-time analysis. Therefore, the amount of data used to assess the integrity of a structure must be significantly reduced. A new type of cross correlation analysis, for which impedance data is instantaneously correlated between different sensor sets and different frequency ranges, as opposed to be correlated to pre-stored baseline data, is proposed to drastically reduce the amount of data to a single correlation coefficient and provide a quantitative means of detecting damage relative to the sensor positions. The proposed analysis is carried out on a 3-story representative structure and its efficiency is demonstrated.
Scattering by a groove in an impedance plane
NASA Technical Reports Server (NTRS)
Bindiganavale, Sunil; Volakis, John L.
1993-01-01
An analysis of two-dimensional scattering from a narrow groove in an impedance plane is presented. The groove is represented by a impedance surface and the problem reduces to that of scattering from an impedance strip in an otherwise uniform impedance plane. On the basis of this model, appropriate integral equations are constructed using a form of the impedance plane Green's functions involving rapidly convergent integrals. The integral equations are solved by introducing a single basis representation of the equivalent current on the narrow impedance insert. Both transverse electric (TE) and transverse magnetic (TM) polarizations are treated. The resulting solution is validated by comparison with results from the standard boundary integral method (BIM) and a high frequency solution. It is found that the presented solution for narrow impedance inserts can be used in conjunction with the high frequency solution for the characterization of impedance inserts of any given width.
Evaluation of a cost-effective loads approach. [shock spectra/impedance method for Viking Orbiter
NASA Technical Reports Server (NTRS)
Garba, J. A.; Wada, B. K.; Bamford, R.; Trubert, M. R.
1976-01-01
A shock spectra/impedance method for loads predictions is used to estimate member loads for the Viking Orbiter, a 7800-lb interplanetary spacecraft that has been designed using transient loads analysis techniques. The transient loads analysis approach leads to a lightweight structure but requires complex and costly analyses. To reduce complexity and cost, a shock spectra/impedance method is currently being used to design the Mariner Jupiter Saturn spacecraft. This method has the advantage of using low-cost in-house loads analysis techniques and typically results in more conservative structural loads. The method is evaluated by comparing the increase in Viking member loads to the loads obtained by the transient loads analysis approach. An estimate of the weight penalty incurred by using this method is presented. The paper also compares the calculated flight loads from the transient loads analyses and the shock spectra/impedance method to measured flight data.
FDTD modeling of thin impedance sheets
NASA Technical Reports Server (NTRS)
Luebbers, Raymond J.; Kunz, Karl S.
1991-01-01
Thin sheets of resistive or dielectric material are commonly encountered in radar cross section calculations. Analysis of such sheets is simplified by using sheet impedances. In this paper it is shown that sheet impedances can be modeled easily and accurately using Finite Difference Time Domain (FDTD) methods.
Stolwijk, Judith A.; Matrougui, Khalid; Renken, Christian W.; Trebak, Mohamed
2014-01-01
The past 20 years have seen significant growth in using impedance-based assays to understand the molecular underpinning of endothelial and epithelial barrier function in response to physiological agonists, pharmacological and toxicological compounds. Most studies on barrier function use G protein coupled receptor (GPCR) agonists which couple to fast and transient changes in barrier properties. The power of impedance based techniques such as Electric Cell-Substrate Impedance Sensing (ECIS) reside in its ability to detect minute changes in cell layer integrity label-free and in real-time ranging from seconds to days. We provide a comprehensive overview of the biophysical principles, applications and recent developments in impedance-based methodologies. Despite extensive application of impedance analysis in endothelial barrier research little attention has been paid to data analysis and critical experimental variables, which are both essential for signal stability and reproducibility. We describe the rationale behind common ECIS data presentation and interpretation and illustrate practical guidelines to improve signal intensity by adapting technical parameters such as electrode layout, monitoring frequency or parameter (resistance versus impedance magnitude). Moreover, we discuss the impact of experimental parameters, including cell source, liquid handling and agonist preparation on signal intensity and kinetics. Our discussions are supported by experimental data obtained from human microvascular endothelial cells challenged with three GPCR agonists, thrombin, histamine and Sphingosine-1-Phosphate. PMID:25537398
Stolwijk, Judith A; Matrougui, Khalid; Renken, Christian W; Trebak, Mohamed
2015-10-01
The past 20 years has seen significant growth in using impedance-based assays to understand the molecular underpinning of endothelial and epithelial barrier function in response to physiological agonists and pharmacological and toxicological compounds. Most studies on barrier function use G protein-coupled receptor (GPCR) agonists which couple to fast and transient changes in barrier properties. The power of impedance-based techniques such as electric cell-substrate impedance sensing (ECIS) resides in its ability to detect minute changes in cell layer integrity label-free and in real-time ranging from seconds to days. We provide a comprehensive overview of the biophysical principles, applications, and recent developments in impedance-based methodologies. Despite extensive application of impedance analysis in endothelial barrier research, little attention has been paid to data analysis and critical experimental variables, which are both essential for signal stability and reproducibility. We describe the rationale behind common ECIS data presentation and interpretation and illustrate practical guidelines to improve signal intensity by adapting technical parameters such as electrode layout, monitoring frequency, or parameter (resistance versus impedance magnitude). Moreover, we discuss the impact of experimental parameters, including cell source, liquid handling, and agonist preparation on signal intensity and kinetics. Our discussions are supported by experimental data obtained from human microvascular endothelial cells challenged with three GPCR agonists, thrombin, histamine, and sphingosine-1-phosphate.
NASA Astrophysics Data System (ADS)
Gur, David; Zheng, Bin; Lederman, Dror; Dhurjaty, Sreeram; Sumkin, Jules; Zuley, Margarita
2010-02-01
A new resonance-frequency based electronic impedance spectroscopy (REIS) system with multi-probes, including one central probe and six external probes that are designed to contact the breast skin in a circular form with a radius of 60 millimeters to the central ("nipple") probe, has been assembled and installed in our breast imaging facility. We are conducting a prospective clinical study to test the performance of this REIS system in identifying younger women (< 50 years old) at higher risk for having or developing breast cancer. In this preliminary analysis, we selected a subset of 100 examinations. Among these, 50 examinations were recommended for a biopsy due to detection of a highly suspicious breast lesion and 50 were determined negative during mammography screening. REIS output signal sweeps that we used to compute an initial feature included both amplitude and phase information representing differences between corresponding (matched) EIS signal values acquired from the left and right breasts. A genetic algorithm was applied to reduce the feature set and optimize a support vector machine (SVM) to classify the REIS examinations into "biopsy recommended" and "non-biopsy" recommended groups. Using the leave-one-case-out testing method, the classification performance as measured by the area under the receiver operating characteristic (ROC) curve was 0.816 +/- 0.042. This pilot analysis suggests that the new multi-probe-based REIS system could potentially be used as a risk stratification tool to identify pre-screened young women who are at higher risk of having or developing breast cancer.
Mendes, Marcílio S; de Moraes, Josué
2014-11-01
In recent years, vector-borne and zoonotic diseases have become a major challenge for public health. Dengue fever and leptospirosis are the most important communicable diseases in Brazil based on their prevalence and the healthy life years lost from disability. The primary strategy for preventing human exposure to these diseases is effective insect and rodent control in and around the home. However, health authorities have difficulties in controlling vector-borne and zoonotic diseases because residents often refuse access to their homes. This study discusses aspects related to the activities performed by Brazilian health authorities to combat vector-borne and zoonotic diseases, particularly difficulties in relation to the legal aspect, which often impede the quick and effective actions of these professionals. How might it be possible to reconcile the need to preserve public health and the rule on the inviolability of the home, especially in the case of abandoned properties or illegal residents and the refusal of residents to allow the health authority access? Do residents have the right to hinder the performance of health workers even in the face of a significant and visible focus of disease transmission? This paper argues that a comprehensive legal plan aimed at the control of invasive vector-borne and zoonotic diseases including synanthropic animals of public health importance should be considered. In addition, this paper aims to bridge the gap between lawyers and public health professionals and to facilitate communication between them. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Bedrosian, Paul A.; Love, Jeffrey J.
2015-12-01
Empirical impedance tensors obtained from EarthScope magnetotelluric data at sites distributed across the midwestern United States are used to examine the feasibility of mapping magnetic storm induction of geoelectric fields. With these tensors, in order to isolate the effects of Earth conductivity structure, we perform a synthetic analysis—calculating geoelectric field variations induced by a geomagnetic field that is geographically uniform but varying sinusoidally with a chosen set of oscillation frequencies that are characteristic of magnetic storm variations. For north-south oriented geomagnetic oscillations at a period of T0=100 s, induced geoelectric field vectors show substantial geographically distributed differences in amplitude (approximately a factor of 100), direction (up to 130∘), and phase (over a quarter wavelength). These differences are the result of three-dimensional Earth conductivity structure, and they highlight a shortcoming of one-dimensional conductivity models (and other synthetic models not derived from direct geophysical measurement) that are used in the evaluation of storm time geoelectric hazards for the electric power grid industry. A hypothetical extremely intense magnetic storm having 500 nT amplitude at T0=100 s would induce geoelectric fields with an average amplitude across the midwestern United States of about 2.71 V/km, but with a representative site-to-site range of 0.15 V/km to 16.77 V/km. Significant improvement in the evaluation of such hazards will require detailed knowledge of the Earth's interior three-dimensional conductivity structure.
Impedance measurement using a two-microphone, random-excitation method
NASA Technical Reports Server (NTRS)
Seybert, A. F.; Parrott, T. L.
1978-01-01
The feasibility of using a two-microphone, random-excitation technique for the measurement of acoustic impedance was studied. Equations were developed, including the effect of mean flow, which show that acoustic impedance is related to the pressure ratio and phase difference between two points in a duct carrying plane waves only. The impedances of a honeycomb ceramic specimen and a Helmholtz resonator were measured and compared with impedances obtained using the conventional standing-wave method. Agreement between the two methods was generally good. A sensitivity analysis was performed to pinpoint possible error sources and recommendations were made for future study. The two-microphone approach evaluated in this study appears to have some advantages over other impedance measuring techniques.
The MUSIC algorithm for impedance tomography of small inclusions from discrete data
NASA Astrophysics Data System (ADS)
Lechleiter, A.
2015-09-01
We consider a point-electrode model for electrical impedance tomography and show that current-to-voltage measurements from finitely many electrodes are sufficient to characterize the positions of a finite number of point-like inclusions. More precisely, we consider an asymptotic expansion with respect to the size of the small inclusions of the relative Neumann-to-Dirichlet operator in the framework of the point electrode model. This operator is naturally finite-dimensional and models difference measurements by finitely many small electrodes of the electric potential with and without the small inclusions. Moreover, its leading-order term explicitly characterizes the centers of the small inclusions if the (finite) number of point electrodes is large enough. This characterization is based on finite-dimensional test vectors and leads naturally to a MUSIC algorithm for imaging the inclusion centers. We show both the feasibility and limitations of this imaging technique via two-dimensional numerical experiments, considering in particular the influence of the number of point electrodes on the algorithm’s images.
NASA Astrophysics Data System (ADS)
Liu, Ying; Zhao, Kun; Drew, Michael G. B.; Liu, Yue
2018-01-01
Reflection loss is usually calculated and reported as a function of the thickness of microwave absorption material. However, misleading results are often obtained since the principles imbedded in the popular methods contradict the fundamental facts that electromagnetic waves cannot be reflected in a uniform material except when there is an interface and that there are important differences between the concepts of characteristic impedance and input impedance. In this paper, these inconsistencies have been analyzed theoretically and corrections provided. The problems with the calculations indicate a gap between the background knowledge of material scientists and microwave engineers and for that reason a concise review of transmission line theory is provided along with the mathematical background needed for a deeper understanding of the theory of reflection loss. The expressions of gradient, divergence, Laplacian, and curl operators in a general orthogonal coordinate system have been presented including the concept of reciprocal vectors. Gauss's and Stokes's theorems have been related to Green's theorem in a novel way.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singh, Lokendra P.; Richert, Ranko, E-mail: ranko@asu.edu; Raihane, Ahmed
2015-01-07
A two-channel impedance technique has been used to study the relaxation behavior of 2-ethyl-1-hexanol with polar and non-polar dopants at the few percent concentration level over a wide temperature and frequency range. The non-polar dopants shift both the Debye and the primary structural relaxation time in the same direction, to shorter times for 3-methylpentane and to longer times for squalane, consistent with the relative glass transition temperatures (T{sub g}) of the components. By contrast, polar dopants such as water or methanol modify the α-process towards slower dynamics and increased amplitude, while the Debye process is accelerated and with a decreasedmore » amplitude. This effect of adding water to alcohol is explained by water promoting more compact structures with reduced Kirkwood correlation factors. This picture is consistent with a shift in the neutron scattering pre-peak to lower scattering vectors and with simulation work on alcohol-water systems.« less
Study of the dopamine effect into cell solutions by impedance analysis
NASA Astrophysics Data System (ADS)
Paivana, G.; Apostolou, T.; Kaltsas, G.; Kintzios, S.
2017-11-01
Electrochemical Impedance Spectroscopy (EIS) has become a technique that is frequently used for biological assays. Impedance is defined as a complex - valued generalization of resistance and varies depending on its use per application field. In health sciences, bioimpedance is widely used as non-invasive and low cost alternative in many medical areas that provides valuable information about health status. This work focuses on assessing the effects of a bioactive substance applied to immobilized cells. Dopamine was used as a stimulant in order to implement impedance analysis with a specific type of cells. Dopamine constitutes one of the most important catecholamine neurotransmitters in both the mammalian central and peripheral nervous systems. The main purpose is to extract calibration curves at different frequencies with known dopamine concentrations in order to describe the behavior of cells applied to dopamine using an impedance measurement device. For comparison purposes, non-immobilized cells were tested for the same dopamine concentrations.
NASA Astrophysics Data System (ADS)
Zheng, Sifa; Liu, Haitao; Dan, Jiabi; Lian, Xiaomin
2015-05-01
Linear time-invariant assumption for the determination of acoustic source characteristics, the source strength and the source impedance in the frequency domain has been proved reasonable in the design of an exhaust system. Different methods have been proposed to its identification and the multi-load method is widely used for its convenience by varying the load number and impedance. Theoretical error analysis has rarely been referred to and previous results have shown an overdetermined set of open pipes can reduce the identification error. This paper contributes a theoretical error analysis for the load selection. The relationships between the error in the identification of source characteristics and the load selection were analysed. A general linear time-invariant model was built based on the four-load method. To analyse the error of the source impedance, an error estimation function was proposed. The dispersion of the source pressure was obtained by an inverse calculation as an indicator to detect the accuracy of the results. It was found that for a certain load length, the load resistance at the frequency points of one-quarter wavelength of odd multiples results in peaks and in the maximum error for source impedance identification. Therefore, the load impedance of frequency range within the one-quarter wavelength of odd multiples should not be used for source impedance identification. If the selected loads have more similar resistance values (i.e., the same order of magnitude), the identification error of the source impedance could be effectively reduced.
Cornish, B H; Ward, L C; Thomas, B J; Jebb, S A; Elia, M
1996-03-01
To assess the application of a Cole-Cole analysis of multiple frequency bioelectrical impedance analysis (MFBIA) measurements to predict total body water (TBW) and extracellular water (ECW) in humans. This technique has previously been shown to produce accurate and reliable estimates in both normal and abnormal animals. The whole body impedance of 60 healthy humans was measured at 496 frequencies (ranging from 4 kHz to 1 MHz) and the impedance at zero frequency, Ro, and at the characteristic frequency, Zc, were determined from the impedance spectrum, (Cole-Cole plot). TBW and ECW were independently determined using deuterium and bromide tracer dilution techniques. At the Dunn Clinical Nutrition Centre and The Department of Biochemistry, University of Queensland. 60 healthy adult volunteers (27 men and 33 women, aged 18-45 years). The results presented suggest that the swept frequency bioimpedance technique estimates total body water, (SEE = 5.2%), and extracellular water, (SEE = 10%), only slightly better in normal, healthy subjects than a method based on single frequency bioimpedance or anthropometric estimates based on weight, height and gender. This study has undertaken the most extensive analysis to date of relationships between TBW (and ECW) and individual impedances obtained at different frequencies ( > 400 frequencies), and has shown marginal advantages of using one frequency over another, even if values predicted from theoretical bioimpedance models are used in the estimations. However in situations where there are disturbances of fluid distribution, values predicted from the Cole-Cole analysis of swept frequency bioimpedance measurements could prove to be more useful.
Frazzoni, M; Conigliaro, R; Mirante, V G; Melotti, G
2012-02-01
By analysis of symptom-reflux association, endoscopy-negative refractory heartburn can be related to acid/non-acid refluxes with impedance-pH monitoring. Unfortunately, patients frequently do not report symptoms during the test. We aimed to assess the contribution of quantitative analysis of impedance-pH parameters added to symptom-reflux association in evaluating patients with endoscopy-negative heartburn refractory to high-dose proton pump inhibitor therapy. The symptom association probability (SAP), the symptom index (SI), the esophageal acid exposure time and the number of distal and proximal refluxes were assessed at on-therapy impedance-pH monitoring. Relationships with hiatal hernia and manometric findings were also evaluated. Eighty patients were prospectively studied. Refractory heartburn was more frequently related to reflux by a positive SAP/SI and/or abnormal impedance-pH parameters (52/80 cases) (65%) than by a positive SAP/SI only (38/80 cases) (47%) (P = 0.038). In patients with refractory non-erosive reflux disease (NERD) defined by a positive SAP/SI and/or abnormal impedance-pH parameters, the prevalence of hiatal hernia was significantly higher (56%vs 21%, P = 0.007) and the mean lower esophageal sphincter tone was significantly lower (18.7 vs 25.8 mmHg, P = 0.005) than in those (35%) with reflux-unrelated, i.e., functional heartburn (FH). On the contrary, no significant difference was observed subdividing patients according to a positive SAP/SI only. Quantitative analysis of impedance-pH parameters added to symptom-reflux association allows a subdivision of refractory-heartburn patients into refractory NERD and FH which is substantiated by pathophysiological findings and which restricts the diagnosis of FH to one third of cases. © 2011 Blackwell Publishing Ltd.
NASA Astrophysics Data System (ADS)
Oz, Alon; Hershkovitz, Shany; Tsur, Yoed
2014-11-01
In this contribution we present a novel approach to analyze impedance spectroscopy measurements of supercapacitors. Transforming the impedance data into frequency-dependent capacitance allows us to use Impedance Spectroscopy Genetic Programming (ISGP) in order to find the distribution function of relaxation times (DFRT) of the processes taking place in the tested device. Synthetic data was generated in order to demonstrate this technique and a model for supercapacitor ageing process has been obtained.
A lumped-circuit model for the radiation impedance of a circular piston in a rigid baffle.
Bozkurt, Ayhan
2008-09-01
The radiation impedance of a piston transducer mounted in a rigid baffle has been widely addressed in the literature. The real and imaginary parts of the impedance are described by the first order Bessel and Struve functions, respectively. Although there are power series expansions for both functions, the analytic formulation of a lumped circuit is not trivial. In this paper, we present an empirical approach to the derivation of a lumped-circuit model for the radiation impedance expression, based on observations on the near-field behavior of stored kinetic and elastic energy. The field analysis is carried out using a finite element method model of the piston and surrounding fluid medium. We show that fluctuations in the real and imaginary components of the impedance can be modeled by series and shunt tank circuits, each of which shape a certain section of the impedance curve. Because the model is composed of lumped-circuit elements, it can be used in circuit simulators. Consequently, the proposed model is useful for the analysis of transducer front-end circuits.
Effects of tissue impedance on heat generation during RF delivery with the Thermage system
NASA Astrophysics Data System (ADS)
Tomkoria, Sara; Pope, Karl
2005-04-01
The Thermage ThermaCool TC system is a non-ablative RF device designed to promote tissue tightening and contouring. The system delivers RF energy to a target area under the skin, with volumetric tissue heating in that area. While the amount of energy delivered to a patient can be controlled by ThermaCool system settings, the distribution of energy to the treatment area and underlying layers is variable from individual to individual due to differences in body composition. The present study investigated how local tissue impedance affects the amount of discomfort experienced by patients during RF energy delivery. Discomfort results from heat generation in the treatment area. By using features of the ThermaCool TC System, local impedance (impedance of the treatment area), bulk impedance (impedance of the underlying tissue layers), and total impedance (the sum of local and bulk impedance) were measured for 35 patients. For each patient, impedance measurements were compared to discomfort levels expressed during treatment. Analysis of whole body, local, and bulk impedance values indicate that the percent of total body impedance in the local treatment area contributes to discomfort levels expressed by patients during treatment.
Humbert, Olivier; Gisch, Don W; Wohlfahrt, Martin E; Adams, Amie B; Greenberg, Phil D; Schmitt, Tom M; Trobridge, Grant D; Kiem, Hans-Peter
2016-08-01
Lentiviral vectors (LVs) pseudotyped with vesicular stomatitis virus envelope glycoprotein (VSV-G) have demonstrated great promise in gene therapy trials employing hematopoietic stem cell and T-cells. The VSV-G envelope confers broad tropism and stability to the vector but is toxic when constitutively expressed, which has impeded efforts to generate stable producer cell lines. We previously showed that cocal pseudotyped LVs offer an excellent alternative to VSV-G vectors because of their broad tropism and resistance to human serum inactivation. In this study, we demonstrate that cocal LVs transduce CD34(+) and CD4(+) T-cells more efficiently than VSV-G LVs and share the same receptor(s) for cell entry. 293T-cells stably expressing the cocal envelope produced significantly higher LV titers than VSV-G expressing cells. We developed cocal pseudotyped, third-generation, self-inactivating LV producer cell lines for a GFP reporter and for a WT1 tumor-specific T-cell receptor, which achieved concentrated titers above 10(8) IU/ml and were successfully adapted for growth in suspension, serum-free culture. The resulting LVs were at least as effective as standard LVs in transducing CD34(+) and CD4(+) T-cells. Our stable cocal LV producer cell lines should facilitate the production of large-scale, high titer clinical grade vectors.
Törer, Nurkan; Aytaç, Özgür
2017-06-01
Conventional 24-h pH monitoring is the gold standard for the diagnosis of non-erosive, non-acidic gastro-esophageal reflux disease. Multichannel Intraluminal Impedance (MII) analysis markedly improves diagnostic accuracy of non-erosive, non-acidic gastro-esophageal reflux disease. However, MII catheters are more expensive than standard catheters. This study aimed to determine the rates of acid or non-acid reflux and by making a retrospective projection, to predict the costs of two algorithms. We retrospectively reviewed the medical data of 102 patients who presented to our hospital with suspected non-erosive GERD and underwent 24 h impedance/pH-monitoring. Demographic characteristics, Demeester scores, number of reflux episodes, and results of impedance analysis were recorded. According to these data, cost was calculated either for the scenario in which impedance measurement was performed solely or following a negative conventional pH monitoring. Thirty-seven of all 102 patients (36.3 %) had a Demeester score greater than 14.7. These patients were assigned as group 1 (acid reflux). The impedance analysis of the remaining 65 patients detected 34 patients (33.3 %) to have more than 50 reflux episodes over a period of 24 h and assigned as Group 2, and 31 patients (30.4 %) had no reflux (group 3). The cost of the single- step algorithm using MII catheter was calculated as $15,300, while the total cost of two-step scenario would have been predicted as $16,890. Our study showed that an initial conventional pH monitoring can make the diagnosis of GERD in only one third of the patients with suspected non-erosive GERD. In nearly two-thirds of patients, however, repeated procedures and use of impedance catheters are needed. It is clear that this algorithm has certain drawbacks with regard to cost, patient comfort, and workforce loss.
Damal, Kavitha; Murrell, Ebony G; Juliano, Steven A; Conn, Jan E; Loew, Sabine S
2013-09-01
The invasive dengue vector Aedes aegypti has persisted for > 200 years in South Florida in the United States. We tested the hypotheses that Florida's landscape creates dispersal barriers and corridors and that long-distance human-aided dispersal structures populations of Ae. aegypti. We evaluated the phylogeography of 362 individuals from Florida's East and West Coasts with a 760-bp (418- and 342-bp fragments of ND5 and ND4, respectively) mitochondrial sequence. Populations from these two coasts were not significantly differentiated, suggesting that limited urbanization in central Florida is not a strong barrier to gene flow. Evidence for long-distance dispersal between Ft. Lauderdale and the West and Ft. Myers and the East indicates the importance of human-aided dispersal. West Coast populations showed no genetic differentiation, indicating that West Coast rivers and bays did not significantly impede gene flow. Phylogeographic analysis of haplotypes showed two distinct matrilines with no geographic patterns, suggesting multiple introductions or balancing selection.
Time-Domain Impedance Boundary Conditions for Computational Aeroacoustics
NASA Technical Reports Server (NTRS)
Tam, Christopher K. W.; Auriault, Laurent
1996-01-01
It is an accepted practice in aeroacoustics to characterize the properties of an acoustically treated surface by a quantity known as impedance. Impedance is a complex quantity. As such, it is designed primarily for frequency-domain analysis. Time-domain boundary conditions that are the equivalent of the frequency-domain impedance boundary condition are proposed. Both single frequency and model broadband time-domain impedance boundary conditions are provided. It is shown that the proposed boundary conditions, together with the linearized Euler equations, form well-posed initial boundary value problems. Unlike ill-posed problems, they are free from spurious instabilities that would render time-marching computational solutions impossible.
NASA Astrophysics Data System (ADS)
Snakowska, Anna; Jurkiewicz, Jerzy; Gorazd, Łukasz
2017-05-01
The paper presents derivation of the impedance matrix based on the rigorous solution of the wave equation obtained by the Wiener-Hopf technique for a semi-infinite unflanged cylindrical duct. The impedance matrix allows, in turn, calculate the acoustic impedance along the duct and, as a special case, the radiation impedance. The analysis is carried out for a multimode incident wave accounting for modes coupling on the duct outlet not only qualitatively but also quantitatively for a selected source operating inside. The quantitative evaluation of the acoustic impedance requires setting of modes amplitudes which has been obtained applying the mode decomposition method to the far-field pressure radiation measurements and theoretical formulae for single mode directivity characteristics for an unflanged duct. Calculation of the acoustic impedance for a non-uniform distribution of the sound pressure and the sound velocity on a duct cross section requires determination of the acoustic power transmitted along/radiated from a duct. In the paper, the impedance matrix, the power, and the acoustic impedance were derived as functions of Helmholtz number and distance from the outlet.
Lewis, George K; Lewis, George K; Olbricht, William
2008-01-01
This paper explains the circuitry and signal processing to perform electrical impedance spectroscopy on piezoelectric materials and ultrasound transducers. Here, we measure and compare the impedance spectra of 2−5 MHz piezoelectrics, but the methodology applies for 700 kHz–20 MHz ultrasonic devices as well. Using a 12 ns wide 5 volt pulsing circuit as an impulse, we determine the electrical impedance curves experimentally using Ohm's law and fast Fourier transform (FFT), and compare results with mathematical models. The method allows for rapid impedance measurement for a range of frequencies using a narrow input pulse, digital oscilloscope and FFT techniques. The technique compares well to current methodologies such as network and impedance analyzers while providing additional versatility in the electrical impedance measurement. The technique is theoretically simple, easy to implement and completed with ordinary laboratory instrumentation for minimal cost. PMID:19081773
Impedance computations and beam-based measurements: A problem of discrepancy
NASA Astrophysics Data System (ADS)
Smaluk, Victor
2018-04-01
High intensity of particle beams is crucial for high-performance operation of modern electron-positron storage rings, both colliders and light sources. The beam intensity is limited by the interaction of the beam with self-induced electromagnetic fields (wake fields) proportional to the vacuum chamber impedance. For a new accelerator project, the total broadband impedance is computed by element-wise wake-field simulations using computer codes. For a machine in operation, the impedance can be measured experimentally using beam-based techniques. In this article, a comparative analysis of impedance computations and beam-based measurements is presented for 15 electron-positron storage rings. The measured data and the predictions based on the computed impedance budgets show a significant discrepancy. Three possible reasons for the discrepancy are discussed: interference of the wake fields excited by a beam in adjacent components of the vacuum chamber, effect of computation mesh size, and effect of insufficient bandwidth of the computed impedance.
An estimation of the electrical characteristics of planetary shallow subsurfaces with TAPIR antennas
NASA Astrophysics Data System (ADS)
Le Gall, A.; Reineix, A.; Ciarletti, V.; Berthelier, J. J.; Ney, R.; Dolon, F.; Corbel, C.
2006-06-01
In the frame of the NETLANDER program, we have developed the Terrestrial And Planetary Investigation by Radar (TAPIR) imaging ground-penetrating radar to explore the Martian subsurface at kilometric depths and search for potential water reservoirs. This instrument which is to operate from a fixed lander is based on a new concept which allows one to image the various underground reflectors by determining the direction of propagation of the reflected waves. The electrical parameters of the shallow subsurface (permittivity and conductivity) need to be known to correctly determine the propagation vector. In addition, these electrical parameters can bring valuable information on the nature of the materials close to the surface. The electric antennas of the radar are 35 m long resistively loaded monopoles that are laid on the ground. Their impedance, measured during a dedicated mode of operation of the radar, depends on the electrical parameters of soil and is used to infer the permittivity and conductivity of the upper layer of the subsurface. This paper presents an experimental and theoretical study of the antenna impedance and shows that the frequency profile of the antenna complex impedance can be used to retrieve the geoelectrical characteristics of the soil. Comparisons between a numerical modeling and in situ measurements have been successfully carried over various soils, showing a very good agreement.
FDTD modeling of thin impedance sheets
NASA Technical Reports Server (NTRS)
Luebbers, Raymond; Kunz, Karl
1991-01-01
Thin sheets of resistive or dielectric material are commonly encountered in radar cross section calculations. Analysis of such sheets is simplified by using sheet impedances. It is shown that sheet impedances can be modeled easily and accurately using Finite Difference Time Domain (FDTD) methods. These sheets are characterized by a discontinuity in the tangential magnetic field on either side of the sheet but no discontinuity in tangential electric field. This continuity, or single valued behavior of the electric field, allows the sheet current to be expressed in terms of an impedance multiplying this electric field.
Forsyth, Colin
2015-11-01
Dressler (2001:456) characterizes medical anthropology as divided between two poles: the constructivist, which focuses on the "meaning and significance that events have for people," and the structuralist, which emphasizes socioeconomic processes and relationships. This study synthesizes structuralist and constructivist perspectives by investigating how structural processes impact explanatory models of Chagas disease in a highly endemic area. The research took place from March-June 2013 through the Centro Medico Humberto Parra, a non-profit clinic servicing low income populations in Palacios, Bolivia and surrounding communities. Semistructured interviews (n = 68) and consensus analysis questionnaires (n = 48) were administered to people dealing with Chagas disease. In the interview narratives, respondents link Chagas disease with experiences of marginalization and rural poverty, and describe multilayered impediments to accessing treatment. They often view the disease as incurable, but this reflects inconsistent messages from the biomedical system. The consensus analysis results show strong agreement on knowledge of the vector, ethnomedical treatment, and structural factors related to Chagas disease. In interpreting Chagas disease, respondents account for the structural factors which place them at risk and impede access to care. Copyright © 2015 Elsevier Ltd. All rights reserved.
Text analysis devices, articles of manufacture, and text analysis methods
Turner, Alan E; Hetzler, Elizabeth G; Nakamura, Grant C
2015-03-31
Text analysis devices, articles of manufacture, and text analysis methods are described according to some aspects. In one aspect, a text analysis device includes a display configured to depict visible images, and processing circuitry coupled with the display and wherein the processing circuitry is configured to access a first vector of a text item and which comprises a plurality of components, to access a second vector of the text item and which comprises a plurality of components, to weight the components of the first vector providing a plurality of weighted values, to weight the components of the second vector providing a plurality of weighted values, and to combine the weighted values of the first vector with the weighted values of the second vector to provide a third vector.
Eliminating the η-problem in SUGRA hybrid inflation with vector backreaction
NASA Astrophysics Data System (ADS)
Dimopoulos, Konstantinos; Lazarides, George; Wagstaff, Jacques M.
2012-02-01
It is shown that, when the inflaton field modulates the gauge kinetic function of the gauge fields in supergravity realisations of inflation, the dynamic backreaction leads to a new inflationary attractor solution, in which the inflaton's variation suffers additional impedance. As a result, slow-roll inflation can naturally occur along directions of the scalar potential which would be too steep and curved to support it otherwise. This provides a generic solution to the infamous eta-problem of inflation in supergravity. Moreover, it is shown that, in the new inflationary attractor, the spectral index of the generated curvature perturbations is kept mildly red despite eta of order unity. The above findings are applied to a model of hybrid inflation in supergravity with a generic Kähler potential. The spectral index of the generated curvature perturbations is found to be 0.97-0.98, in excellent agreement with observations. The gauge field can play the role of the vector curvaton after inflation but observable statistical anisotropy requires substantial tuning of the gauge coupling.
A Practical Approach for Analysis of Input and Output Impedances of Feedback Amplifiers
ERIC Educational Resources Information Center
Abramovitz, A.
2009-01-01
This paper suggests a pedagogical approach to teaching the subject of the analysis of feedback amplifiers for electrical engineering students at the undergraduate level. Special attention is given to derivation of the input and output impedances. In order to make the procedure clear and suitable for classroom presentation an alternative proof of…
Impedance computations and beam-based measurements: A problem of discrepancy
Smaluk, Victor
2018-04-21
High intensity of particle beams is crucial for high-performance operation of modern electron-positron storage rings, both colliders and light sources. The beam intensity is limited by the interaction of the beam with self-induced electromagnetic fields (wake fields) proportional to the vacuum chamber impedance. For a new accelerator project, the total broadband impedance is computed by element-wise wake-field simulations using computer codes. For a machine in operation, the impedance can be measured experimentally using beam-based techniques. In this article, a comparative analysis of impedance computations and beam-based measurements is presented for 15 electron-positron storage rings. The measured data and the predictionsmore » based on the computed impedance budgets show a significant discrepancy. For this article, three possible reasons for the discrepancy are discussed: interference of the wake fields excited by a beam in adjacent components of the vacuum chamber, effect of computation mesh size, and effect of insufficient bandwidth of the computed impedance.« less
Impedance computations and beam-based measurements: A problem of discrepancy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smaluk, Victor
High intensity of particle beams is crucial for high-performance operation of modern electron-positron storage rings, both colliders and light sources. The beam intensity is limited by the interaction of the beam with self-induced electromagnetic fields (wake fields) proportional to the vacuum chamber impedance. For a new accelerator project, the total broadband impedance is computed by element-wise wake-field simulations using computer codes. For a machine in operation, the impedance can be measured experimentally using beam-based techniques. In this article, a comparative analysis of impedance computations and beam-based measurements is presented for 15 electron-positron storage rings. The measured data and the predictionsmore » based on the computed impedance budgets show a significant discrepancy. For this article, three possible reasons for the discrepancy are discussed: interference of the wake fields excited by a beam in adjacent components of the vacuum chamber, effect of computation mesh size, and effect of insufficient bandwidth of the computed impedance.« less
Whole-body impedance--what does it measure?
Foster, K R; Lukaski, H C
1996-09-01
Although the bioelectrical impedance technique is widely used in human nutrition and clinical research, an integrated summary of the biophysical and bioelectrical bases of this approach is lacking. We summarize the pertinent electrical phenomena relevant to the application of the impedance technique in vivo and discuss the relations between electrical measurements and biological conductor volumes. Key terms in the derivation of bioelectrical impedance analysis are described and the relation between the electrical properties of tissues and tissue structure is discussed. The relation between the impedance of an object and its geometry, scale, and intrinsic electrical properties is also discussed. Correlations between whole-body impedance measurements and various bioconductor volumes, such as total body water and fat-free mass, are experimentally well established; however, the reason for the success of the impedence technique is much less clear. The bioengineering basis for the technique is critically presented and considerations are proposed that might help to clarify the method and potentially improve its sensitivity.
Positional dependence of particles in microfludic impedance cytometry.
Spencer, Daniel; Morgan, Hywel
2011-04-07
Single cell impedance cytometry is a label-free electrical analysis method that requires minimal sample preparation and has been used to count and discriminate cells on the basis of their impedance properties. This paper shows experimental and numerically simulated impedance signals for test particles (6 μm diameter polystyrene) flowing through a microfluidic channel. The variation of impedance signal with particle position is mapped using numerical simulation and these results match closely with experimental data. We demonstrate that for a nominal 40 μm × 40 μm channel, the impedance signal is independent of position over the majority of the channel area, but shows large experimentally verifiable variation at extreme positions. The parabolic flow profile in the channel ensures that most of the sample flows through the area of uniform signal. At high flow rates inertial focusing is observed; the particles flow in equal numbers through two equilibrium positions reducing the coefficient of variance (CV) in the impedance signals to negligible values.
Dieng, Hamady; Tan Yusop, Nur Syafiqah Bt; Kamal, Nurafidah Natasyah Bt; Ahmad, Abu Hassan; Ghani, Idris Abd; Abang, Fatimah; Satho, Tomomitsu; Ahmad, Hamdan; Zuharah, Wan Fatma; Majid, Abdul Hafiz Ab; Morales, Ronald E; Morales, Noppawan P; Hipolito, Cirilo N; Noweg, Gabriel Tonga
2016-05-11
Dengue mosquitoes are evolving into a broader global public health menace, with relentless outbreaks and the rise in number of Zika virus disease cases as reminders of the continued hazard associated with Aedes vectors. The use of chemical insecticides-the principal strategy against mosquito vectors-has been greatly impeded due to the development of insecticide resistance and the shrinking spectrum of effective agents. Therefore, there is a pressing need for new chemistries for vector control. Tea contains hundreds of chemicals, and its waste, which has become a growing global environmental problem, is almost as rich in toxicants as green leaves. This paper presents the toxic and sublethal effects of different crude extracts of tea on Aedes albopictus. The survival rates of larvae exposed to tea extracts, especially fresh tea extract (FTE), were markedly lower than those in the control treatment group. In addition to this immediate toxicity against different developmental stages, the extracts tested caused a broad range of sublethal effects. The developmental time was clearly longer in containers with tea, especially in those with young larvae (YL) and FTE. Among the survivors, pupation success was reduced in containers with tea, which also produced low adult emergence rates with increasing tea concentration. The production of eggs tended to be reduced in females derived from the tea treatment groups. These indirect effects of tea extracts on Ae. albopictus exhibited different patterns according to the exposed larval stage. Taken together, these findings indicate that tea and its waste affect most key components of Ae. albopictus vectorial capacity and may be useful for dengue control. Reusing tea waste in vector control could also be a practical solution to the problems associated with its pollution.
Cost-effectiveness of environmental management for vector control in resource development projects.
Bos, R
1991-01-01
Vector control methods are traditionally divided in chemical, biological and environmental management approaches, and this distinction also reflected in certain financial and economic aspects. This is particularly true for environmental modification, usually engineering or other structural works. It is highly capital intensive, as opposed to chemical and biological control which require recurrent expenditures, and discount rates are therefore a prominent consideration in deciding for one or the other approach. Environmental manipulation requires recurrent action, but can often be carried out with the community participation, which raises the issue of opportunity costs. The incorporation of environmental management in resource projects is generally impeded by economic considerations. The Internal Rate of Return continues to be a crucial criterion for funding agencies and development banks to support new projects; at the same time Governments of debt-riden countries in the Third World will do their best to avoid additional loans on such frills as environmental and health safeguards. Two approaches can be recommended to nevertheless ensure the incorporation of environmental management measures in resource projects in an affordable way. First, there are several examples of cases where environmental management measures either have a dual benefit (increasing both agricultural production and reducing vector-borne disease transmission) or can be implemented at zero costs. Second, the additional costs involved in structural modifications can be separated from the project development costs considered in the calculations of the Internal Rate of Return, and financial support can be sought from bilateral technical cooperation agencies particularly interested in environmental and health issues. There is a dearth of information in the cost-effectiveness of alternative vector control strategies in the developing country context. The process of integrating vector control in the general health services will make it even more difficult to gain a clear insight in the matter.
Vibration analysis of rotor systems using reduced subsystem models
NASA Technical Reports Server (NTRS)
Fan, Uei-Jiun; Noah, Sherif T.
1989-01-01
A general impedance method using reduced submodels has been developed for the linear dynamic analysis of rotor systems. Formulated in terms of either modal or physical coordinates of the subsystems, the method enables imbalance responses at specific locations of the rotor systems to be efficiently determined from a small number of 'master' degrees of freedom. To demonstrate the capability of this impedance approach, the Space Shuttle Main Engine high-pressure oxygen turbopump has been investigated to determine the bearing loads due to imbalance. Based on the same formulation, an eigenvalue analysis has been performed to study the system stability. A small 5-DOF model has been utilized to illustrate the application of the method to eigenvalue analysis. Because of its inherent characteristics of allowing formulation of reduced submodels, the impedance method can significantly increase the computational speed.
Improved Estimation of Electron Temperature from Rocket-borne Impedance Probes
NASA Astrophysics Data System (ADS)
Rowland, D. E.; Wolfinger, K.; Stamm, J. D.
2017-12-01
The impedance probe technique is a well known method for determining high accuracy measurements of electron number density in the Earth's ionosphere. We present analysis of impedance probe data from several sounding rockets at low, mid-, and auroral latitudes, including high cadence estimates of the electron temperature, derived from analytical fits to the antenna impedance curves. These estimates compare favorably with independent estimates from Langmuir Probes, but at much higher temporal and spatial resolution, providing a capability to resolve small-scale temperature fluctuations. We also present some considerations for the design of impedance probes, including assessment of the effects of resonance damping due to rocket motion, effects of wake and spin modulation, and aspect angle to the magnetic field.
Ida, Midori; Hirata, Masakazu; Hosoda, Kiminori; Nakao, Kazuwa
2013-02-01
Two novel bioelectrical impedance analysis (BIA) methods have been developed recently for evaluation of intra-abdominal fat accumulation. Both methods use electrodes that are placed on abdominal wall and allow evaluation of intra-abdominal fat area (IAFA) easily without radiation exposure. Of these, "abdominal BIA" method measures impedance distribution along abdominal anterior-posterior axis, and IAFA by BIA method(BIA-IAFA) is calculated from waist circumference and the voltage occurring at the flank. Dual BIA method measures impedance of trunk and body surface at the abdominal level and calculates BIA-IAFA from transverse and antero-posterior diameters of the abdomen and the impedance of trunk and abdominal surface. BIA-IAFA by these two BIA methods correlated well with IAFA measured by abdominal CT (CT-IAFA) with correlatipn coefficient of 0.88 (n = 91, p < 0.0001) for the former, and 0.861 (n = 469, p < 0.01) for the latter. These new BIA methods are useful for evaluating abdominal adiposity in clinical study and routine clinical practice of metabolic syndrome and obesity.
NASA Astrophysics Data System (ADS)
Schulz, Tobias; Weinmüller, Christian; Nabavi, Majid; Poulikakos, Dimos
A single cell micro-direct methanol fuel cell (micro-DMFC) was investigated using electrochemical impedance spectroscopy. The electrodes consisted of thin, flexible polymer (SU8) film microchannel structures fabricated in-house using microfabrication techniques. AC impedance spectroscopy was used to separate contributions to the overall cell polarization from the anode, cathode and membrane. A clear distinction between the different electrochemical phenomena occurring in the micro-DMFC, especially the distinction between double layer charging and Faradaic reactions was shown. The effect of fuel flow rate, temperature, and anode flow channel structure on the impedance of the electrode reactions and membrane/electrode double layer charging were investigated. Analysis of impedance data revealed that the performance of the test cell was largely limited by the presence of intermediate carbon monoxide in the anode reaction. Higher temperatures increase cell performance by enabling intermediate CO to be oxidized at much higher rates. The results also revealed that serpentine anode flow microchannels show a lower tendency to intermediate CO coverage and a more stable cell behavior than parallel microchannels.
Energy absorption as a predictor of leg impedance in highly trained females.
Kulas, Anthony S; Schmitz, Randy J; Schultz, Sandra J; Watson, Mary Allen; Perrin, David H
2006-08-01
Although leg spring stiffness represents active muscular recruitment of the lower extremity during dynamic tasks such as hopping and running, the joint-specific characteristics comprising the damping portion of this measure, leg impedance, are uncertain. The purpose of this investigation was to assess the relationship between leg impedance and energy absorption at the ankle, knee, and hip during early (impact) and late (stabilization) phases of landing. Twenty highly trained female dancers (age = 20.3 +/- 1.4 years, height = 163.7 +/- 6.0 cm, mass = 62.1 +/- 8.1 kg) were instrumented for biomechanical analysis. Subjects performed three sets of double-leg landings from under preferred, stiff, and soft landing conditions. A stepwise linear regression analysis revealed that ankle and knee energy absorption at impact, and knee and hip energy absorption during the stabilization phases of landing explained 75.5% of the variance in leg impedance. The primary predictor of leg impedance was knee energy absorption during the stabilization phase, independently accounting for 55% of the variance. Future validation studies applying this regression model to other groups of individuals are warranted.
Artifacts and power corrections: Reexamining Z{sub {psi}}(p{sup 2}) and Z{sub V} in the momentum-subtraction scheme
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boucaud, Ph.; Leroy, J. P.; Le Yaouanc, A.
2006-08-01
The next-to-leading-order (NLO) term in the operator product expansion (OPE) of the quark propagator vector part Z{sub {psi}} and the vertex function g{sub 1} of the vector current in the Landau gauge should be dominated by the same condensate as in the gluon propagator. On the other hand, the perturbative part has been calculated to a very high precision thanks to Chetyrkin and collaborators. We test this on the lattice, with both clover and overlap fermion actions at {beta}=6.0, 6.4, 6.6, 6.8. Elucidation of discretization artifacts appears to be absolutely crucial. First hypercubic artifacts are eliminated by amore » powerful method, which gives results notably different from the standard democratic method. Then, the presence of unexpected, very large, nonperturbative, O(4) symmetric discretization artifacts, increasing towards small momenta, is demonstrated by considering Z{sub V}{sup MOM}, which should be constant in the absence of such artifacts. They impede in general the analysis of OPE. However, in two special cases with overlap action--(1) for Z{sub {psi}}; (2) for g{sub 1}, but only at large p{sup 2}--we are able to identify the condensate; it agrees with the one resulting from gluonic Green functions. We conclude that the OPE analysis of quark and gluon Green function has reached a quite consistent status, and that the power corrections have been correctly identified. A practical consequence of the whole analysis is that the renormalization constant Z{sub {psi}} (=Z{sub 2}{sup -1} of the momentum-subtraction (MOM) scheme) may differ sizably from the one given by democratic selection methods. More generally, the values of the renormalization constants may be seriously affected by the differences in the treatment of the various types of artifacts, and by the subtraction of power corrections.« less
Graphical Acoustic Liner Design and Analysis Tool
NASA Technical Reports Server (NTRS)
Howerton, Brian M. (Inventor); Jones, Michael G. (Inventor)
2016-01-01
An interactive liner design and impedance modeling tool comprises software utilized to design acoustic liners for use in constrained spaces, both regularly and irregularly shaped. A graphical user interface allows the acoustic channel geometry to be drawn in a liner volume while the surface impedance calculations are updated and displayed in real-time. A one-dimensional transmission line model may be used as the basis for the impedance calculations.
NASA Astrophysics Data System (ADS)
Kapica, Dominik; Warchulińska, Joanna; Jakubiak, Monika; Teter, Mariusz; Mlak, Radosław; Hałabiś, Magdalena; Wójcik, Waldemar; Małecka-Massalska, Teresa
2015-09-01
Introduction: Bioelectrical impedance analysis (BIA) is a useful tool to asses human body composition and nutrition status; multi-frequency BIA has a higher accuracy than single-frequency BIA. In our study a difference of impedance values (Z) at 5, 100 and 200 kHz and Z200/Z5 index between professional athletes and control group were determined. Methods: In this research 105 people were tested, divided into control group (72 people: 35 males and 37 females) and professional athletes (33 people: 16 males and 17 females). Impedance was measured at three frequency values - 5, 100 and 200 kHz; with received values the Z200/Z5 index was calculated. Results: In most compared subgroups impedance values showed significantly lower values in athletes than in control group (5 kHz - males: p=0.136, females: p=0.001, 100 kHz - males: p=0.039, females: p<0.0001, 200 kHz - males: p=0.047, females: p<0.0001) Z200/Z5 index also showed lower value in athletes than in control group (p=0.016 for males, p<0.0001 for females). Conclusion: Lower values of impedance and Z200/Z5 index indicates a better nutrition status and general health condition of athletes than in control group.
Electromagnetic scattering by impedance structures
NASA Technical Reports Server (NTRS)
Balanis, Constantine A.; Griesser, Timothy
1987-01-01
The scattering of electromagnetic waves from impedance structures is investigated, and current work on antenna pattern calculation is presented. A general algorithm for determining radiation patterns from antennas mounted near or on polygonal plates is presented. These plates are assumed to be of a material which satisfies the Leontovich (or surface impedance) boundary condition. Calculated patterns including reflection and diffraction terms are presented for numerious geometries, and refinements are included for antennas mounted directly on impedance surfaces. For the case of a monopole mounted on a surface impedance ground plane, computed patterns are compared with experimental measurements. This work in antenna pattern prediction forms the basis of understanding of the complex scattering mechanisms from impedance surfaces. It provides the foundation for the analysis of backscattering patterns which, in general, are more problematic than calculation of antenna patterns. Further proposed study of related topics, including surface waves, corner diffractions, and multiple diffractions, is outlined.
Method of estimating pulse response using an impedance spectrum
Morrison, John L; Morrison, William H; Christophersen, Jon P; Motloch, Chester G
2014-10-21
Electrochemical Impedance Spectrum data are used to predict pulse performance of an energy storage device. The impedance spectrum may be obtained in-situ. A simulation waveform includes a pulse wave with a period greater than or equal to the lowest frequency used in the impedance measurement. Fourier series coefficients of the pulse train can be obtained. The number of harmonic constituents in the Fourier series are selected so as to appropriately resolve the response, but the maximum frequency should be less than or equal to the highest frequency used in the impedance measurement. Using a current pulse as an example, the Fourier coefficients of the pulse are multiplied by the impedance spectrum at corresponding frequencies to obtain Fourier coefficients of the voltage response to the desired pulse. The Fourier coefficients of the response are then summed and reassembled to obtain the overall time domain estimate of the voltage using the Fourier series analysis.
Point source moving above a finite impedance reflecting plane - Experiment and theory
NASA Technical Reports Server (NTRS)
Norum, T. D.; Liu, C. H.
1978-01-01
A widely used experimental version of the acoustic monopole consists of an acoustic driver of restricted opening forced by a discrete frequency oscillator. To investigate the effects of forward motion on this source, it was mounted above an automobile and driven over an asphalt surface at constant speed past a microphone array. The shapes of the received signal were compared to results computed from an analysis of a fluctuating-mass-type point source moving above a finite impedance reflecting plane. Good agreement was found between experiment and theory when a complex normal impedance representative of a fairly hard acoustic surface was used in the analysis.
Dielectric relaxation study of Pb(Yb0.5Ta0.5)O3 near ferroelectric phase transition
NASA Astrophysics Data System (ADS)
Praharaj, S.; Biswas, P.; Rout, D.
2018-05-01
The dielectric relaxation study of Pb(Yb0.5Ta0.5)O3 was investigated by dielectric and impedance measurements. A weak relaxor behavior was observed in the specimen near to the antiferroelectric to ferroelectric phase transition. The frequency dependence of Tm analysis confirms the existence of polar nano regions and the interaction between them as well. The depressed semicircles in the impedance plot suggest poly dispersive (non Debye type) nature of the dielectric phenomena in the sample. The dielectric relaxation was further investigated through the analysis of frequency dependence imaginary part of impedance and modulus data.
Wavelet analysis of the impedance cardiogram waveforms
NASA Astrophysics Data System (ADS)
Podtaev, S.; Stepanov, R.; Dumler, A.; Chugainov, S.; Tziberkin, K.
2012-12-01
Impedance cardiography has been used for diagnosing atrial and ventricular dysfunctions, valve disorders, aortic stenosis, and vascular diseases. Almost all the applications of impedance cardiography require determination of some of the characteristic points of the ICG waveform. The ICG waveform has a set of characteristic points known as A, B, E ((dZ/dt)max) X, Y, O and Z. These points are related to distinct physiological events in the cardiac cycle. Objective of this work is an approbation of a new method of processing and interpretation of the impedance cardiogram waveforms using wavelet analysis. A method of computer thoracic tetrapolar polyrheocardiography is used for hemodynamic registrations. Use of original wavelet differentiation algorithm allows combining filtration and calculation of the derivatives of rheocardiogram. The proposed approach can be used in clinical practice for early diagnostics of cardiovascular system remodelling in the course of different pathologies.
Antibody biosensors for spoilage yeast detection based on impedance spectroscopy.
Tubía, I; Paredes, J; Pérez-Lorenzo, E; Arana, S
2018-04-15
Brettanomyces is a yeast species responsible for wine and cider spoilage, producing volatile phenols that result in off-odors and loss of fruity sensorial qualities. Current commercial detection methods for these spoilage species are liable to frequent false positives, long culture times and fungal contamination. In this work, an interdigitated (IDE) biosensor was created to detect Brettanomyces using immunological reactions and impedance spectroscopy analysis. To promote efficient antibody immobilization on the electrodes' surface and to decrease non-specific adsorption, a Self-Assembled Monolayer (SAM) was developed. An impedance spectroscopy analysis, over four yeast strains, confirmed our device's increased efficacy. Compared to label-free sensors, antibody biosensors showed a higher relative impedance. The results also suggested that these biosensors could be a promising method to monitor some spoilage yeasts, offering an efficient alternative to the laborious and expensive traditional methods. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Miyake, Y.; Usui, H.; Kojima, H.; Omura, Y.; Matsumoto, H.
2008-06-01
We have newly developed a numerical tool for the analysis of antenna impedance in plasma environment by making use of electromagnetic Particle-In-Cell (PIC) plasma simulations. To validate the developed tool, we first examined the antenna impedance in a homogeneous kinetic plasma and confirmed that the obtained results basically agree with the conventional theories. We next applied the tool to examine an ion-sheathed dipole antenna. The results confirmed that the inclusion of the ion-sheath effects reduces the capacitance below the electron plasma frequency. The results also revealed that the signature of impedance resonance observed at the plasma frequency is modified by the presence of the sheath. Since the sheath dynamics can be solved by the PIC scheme throughout the antenna analysis in a self-consistent manner, the developed tool has feasibility to perform more practical and complicated antenna analyses that will be necessary in real space missions.
ERIC Educational Resources Information Center
Company, Joe; Ball, Stephen
2010-01-01
The primary purpose of this study was to investigate the accuracy of the DF50 (ImpediMed Ltd, Eight Mile Plains, Queensland, Australia) bioelectrical impedance analysis device using dual-energy x-ray absorptiometry as the criterion in two groups: endurance athletes and power athletes. The secondary purpose was to develop accurate body fat…
Smartphone-Based Bioelectrical Impedance Analysis Devices for Daily Obesity Management
Choi, Ahyoung; Kim, Justin Younghyun; Jo, Seongwook; Jee, Jae Hwan; Heymsfield, Steven B.; Bhagat, Yusuf A.; Kim, Insoo; Cho, Jaegeol
2015-01-01
Current bioelectric impedance analysis (BIA) systems are often large, cumbersome devices which require strict electrode placement on the user, thus inhibiting mobile capabilities. In this work, we developed a handheld BIA device that measures impedance from multiple frequencies (5 kHz~200 kHz) with four contact electrodes and evaluated the BIA device against standard body composition analysis systems: a dual-energy X-ray absorptiometry (DXA) system (GE Lunar Prodigy, GE Healthcare, Buckinghamshire, UK) and a whole-body BIA system (InBody S10, InBody, Co. Ltd, Seoul, Korea). In the study, 568 healthy participants, varying widely in body mass index, age, and gender, were recruited at two research centers: the Samsung Medical Center (SMC) in South Korea and the Pennington Biomedical Research Center (PBRC) in the United States. From the measured impedance data, we analyzed individual body fat and skeletal muscle mass by applying linear regression analysis against target reference data. Results indicated strong correlations of impedance measurements between the prototype pathways and corresponding InBody S10 electrical pathways (R = 0.93, p < 0.0001). Additionally, body fat estimates from DXA did not yield significant differences (p > 0.728 (paired t-test), DXA mean body fat 29.45 ± 10.77 kg, estimated body fat 29.52 ± 12.53 kg). Thus, this portable BIA system shows a promising ability to estimate an individual’s body composition that is comparable to large stationary BIA systems. PMID:26364636
NASA Astrophysics Data System (ADS)
Zhu, J. G.; Sun, Z. C.; Wei, X. Z.; Dai, H. F.
2015-01-01
The power battery thermal management problem in EV (electric vehicle) and HEV (hybrid electric vehicle) has been widely discussed, and EIS (electrochemical impedance spectroscopy) is an effective experimental method to test and estimate the status of the battery. Firstly, an electrochemical-based impedance matrix analysis for lithium-ion battery is developed to describe the impedance response of electrochemical impedance spectroscopy. Then a method, based on electrochemical impedance spectroscopy measurement, has been proposed to estimate the internal temperature of power lithium-ion battery by analyzing the phase shift and magnitude of impedance at different ambient temperatures. Respectively, the SoC (state of charge) and temperature have different effects on the impedance characteristics of battery at various frequency ranges in the electrochemical impedance spectroscopy experimental study. Also the impedance spectrum affected by SoH (state of health) is discussed in the paper preliminary. Therefore, the excitation frequency selected to estimate the inner temperature is in the frequency range which is significantly influenced by temperature without the SoC and SoH. The intrinsic relationship between the phase shift and temperature is established under the chosen excitation frequency. And the magnitude of impedance related to temperature is studied in the paper. In practical applications, through obtaining the phase shift and magnitude of impedance, the inner temperature estimation could be achieved. Then the verification experiments are conduced to validate the estimate method. Finally, an estimate strategy and an on-line estimation system implementation scheme utilizing battery management system are presented to describe the engineering value.
Ravi, K; Geno, D M; Vela, M F; Crowell, M D; Katzka, D A
2017-05-01
Baseline impedance measured with ambulatory impedance pH monitoring (MII-pH) and a mucosal impedance catheter detects gastroesophageal reflux disease (GERD). However, these tools are limited by cost or patient tolerance. We investigated whether baseline impedance measured during high-resolution impedance manometry (HRIM) distinguishes GERD patients from controls. Consecutive patients with clinical HRIM and MII-pH testing were identified. Gastroesophageal reflux disease was defined by esophageal pH <4 for ≥5% of both the supine and total study time, whereas controls had an esophageal pH <4 for ≤3% of the study performed off PPI. Baseline impedance was measured over 15 seconds during the landmark period of HRIM and over three 10 minute intervals during the overnight period of MII-pH. Among 29 GERD patients and 26 controls, GERD patients had a mean esophageal acid exposure time of 22.7% compared to 1.2% in controls (P<.0001). Mean baseline impedance during HRIM was lower in GERD (1061 Ω) than controls (2814 Ω) (P<.0001). Baseline mucosal impedance measured during HRIM and MII-pH correlated (r=0.59, P<.0001). High-resolution esophageal manometry baseline impedance had high diagnostic accuracy for GERD, with an area under the curve (AUC) of 0.931 on receiver operating characteristics (ROC) analysis. A HRIM baseline impedance threshold of 1582 Ω had a sensitivity of 86.2% and specificity of 88.5% for GERD, with a positive predictive value of 89.3% and negative predictive value of 85.2%. Baseline impedance measured during HRIM can reliably discriminate GERD patients with at least moderate esophageal acid exposure from controls. This diagnostic tool may represent an accurate, cost-effective, and less invasive test for GERD. © 2016 John Wiley & Sons Ltd.
Rababah, A S; Walsh, S J; Manoharan, G; Walsh, P R; Escalona, O J
2016-07-01
Intracardiac impedance (ICI) is a major determinant of success during internal cardioversion of atrial fibrillation (AF). However, there have been few studies that have examined the dynamic behaviour of atrial impedance during internal cardioversion in relation to clinical outcome. In this study, voltage and current waveforms captured during internal cardioversion of acute AF in ovine models using novel radiofrequency (RF) generated low-tilt rectilinear and conventional capacitor-discharge based shock waveforms were retrospectively analysed using a digital signal processing algorithm to investigate the dynamic behaviour of atrial impedance during cardioversion. The algorithm was specifically designed to facilitate the simultaneous analysis of multiple impedance parameters, including: mean intracardiac impedance (Z M), intracardiac impedance variance (ICIV) and impedance amplitude spectrum area (IAMSA) for each cardioversion event. A significant reduction in ICI was observed when comparing two successive shocks of increasing energy where cardioversion outcome was successful. In addition, ICIV and IAMSA variables were found to inversely correlate to the magnitude of energy delivered; with a stronger correlation found to the former parameter. In conclusion, ICIV and IAMSA have been evidenced as two key dynamic intracardiac impedance variables that may prove useful in better understanding of the cardioversion process and that could potentially act as prognostic markers with respect to clinical outcome.
NASA Astrophysics Data System (ADS)
Yu, Zhang; Xiaohui, Song; Jianfang, Li; Fei, Gao
2017-05-01
Cable overheating will lead to the cable insulation level reducing, speed up the cable insulation aging, even easy to cause short circuit faults. Cable overheating risk identification and warning is nessesary for distribution network operators. Cable overheating risk warning method based on impedance parameter estimation is proposed in the paper to improve the safty and reliability operation of distribution network. Firstly, cable impedance estimation model is established by using least square method based on the data from distribiton SCADA system to improve the impedance parameter estimation accuracy. Secondly, calculate the threshold value of cable impedance based on the historical data and the forecast value of cable impedance based on the forecasting data in future from distribiton SCADA system. Thirdly, establish risks warning rules library of cable overheating, calculate the cable impedance forecast value and analysis the change rate of impedance, and then warn the overheating risk of cable line based on the overheating risk warning rules library according to the variation relationship between impedance and line temperature rise. Overheating risk warning method is simulated in the paper. The simulation results shows that the method can identify the imedance and forecast the temperature rise of cable line in distribution network accurately. The result of overheating risk warning can provide decision basis for operation maintenance and repair.
Climate change and health in Earth's future
NASA Astrophysics Data System (ADS)
Bowles, Devin C.; Butler, Colin D.; Friel, Sharon
2014-02-01
Threats to health from climate change are increasingly recognized, yet little research into the effects upon health systems is published. However, additional demands on health systems are increasingly documented. Pathways include direct weather impacts, such as amplified heat stress, and altered ecological relationships, including alterations to the distribution and activity of pathogens and vectors. The greatest driver of demand on future health systems from climate change may be the alterations to socioeconomic systems; however, these "tertiary effects" have received less attention in the health literature. Increasing demands on health systems from climate change will impede health system capacity. Changing weather patterns and sea-level rise will reduce food production in many developing countries, thus fostering undernutrition and concomitant disease susceptibility. Associated poverty will impede people's ability to access and support health systems. Climate change will increase migration, potentially exposing migrants to endemic diseases for which they have limited resistance, transporting diseases and fostering conditions conducive to disease transmission. Specific predictions of timing and locations of migration remain elusive, hampering planning and misaligning needs and infrastructure. Food shortages, migration, falling economic activity, and failing government legitimacy following climate change are also "risk multipliers" for conflict. Injuries to combatants, undernutrition, and increased infectious disease will result. Modern conflict often sees health personnel and infrastructure deliberately targeted and disease surveillance and eradication programs obstructed. Climate change will substantially impede economic growth, reducing health system funding and limiting health system adaptation. Modern medical care may be snatched away from millions who recently obtained it.
Theoretical interpretation of Warburg's impedance in unsupported electrolytic cells.
Barbero, G
2017-12-13
We discuss the origin of Warburg's impedance in unsupported electrolytic cells containing only one group of positive and one group of negative ions. Our analysis is based on the Poisson-Nernst-Planck model, where the generation-recombination phenomenon is neglected. We show that to observe Warburg-like impedance the diffusion coefficient of the positive ions has to differ from that of the negative ones, and furthermore the electrodes have to be not blocking. We assume that the non-blocking properties of the electrodes can be described by means of an Ohmic model, where the charge exchange between the cell and the external circuit is described by means of an electrode conductivity. For simplicity we consider a symmetric cell. However, our analysis can be easily generalized to more complicated situations, where the cell is not symmetric and the charge exchange is described by the Chang-Jaffe model, or by a linearized version of the Butler-Volmer equation. Our analysis allows justification of the expression for Warburg's impedance proposed previously by several groups, based on wrong assumptions.
Evaluation of a cost-effective loads approach. [for Viking Orbiter light weight structural design
NASA Technical Reports Server (NTRS)
Garba, J. A.; Wada, B. K.; Bamford, R.; Trubert, M. R.
1976-01-01
A shock spectra/impedance method for loads prediction is used to estimate member loads for the Viking Orbiter, a 7800-lb interplanetary spacecraft that has been designed using transient loads analysis techniques. The transient loads analysis approach leads to a lightweight structure but requires complex and costly analyses. To reduce complexity and cost a shock spectra/impedance method is currently being used to design the Mariner Jupiter Saturn spacecraft. This method has the advantage of using low-cost in-house loads analysis techniques and typically results in more conservative structural loads. The method is evaluated by comparing the increase in Viking member loads to the loads obtained by the transient loads analysis approach. An estimate of the weight penalty incurred by using this method is presented. The paper also compares the calculated flight loads from the transient loads analyses and the shock spectra/impedance method to measured flight data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, L.; Li, Y.
2015-02-03
This paper analyzes the longitudinal space charge impedances of a round uniform beam inside a rectangular and parallel plate chambers using the image charge method. This analysis is valid for arbitrary wavelengths, and the calculations converge rapidly. The research shows that only a few of the image beams are needed to obtain a relative error less than 0.1%. The beam offset effect is also discussed in the analysis.
NASA Astrophysics Data System (ADS)
Kalanov, Temur Z.
2014-03-01
A critical analysis of the foundations of standard vector calculus is proposed. The methodological basis of the analysis is the unity of formal logic and of rational dialectics. It is proved that the vector calculus is incorrect theory because: (a) it is not based on a correct methodological basis - the unity of formal logic and of rational dialectics; (b) it does not contain the correct definitions of ``movement,'' ``direction'' and ``vector'' (c) it does not take into consideration the dimensions of physical quantities (i.e., number names, denominate numbers, concrete numbers), characterizing the concept of ''physical vector,'' and, therefore, it has no natural-scientific meaning; (d) operations on ``physical vectors'' and the vector calculus propositions relating to the ''physical vectors'' are contrary to formal logic.
ERIC Educational Resources Information Center
Andreacci, Joseph L.; Dixon, Curt B.; Rompolski, Krista; VanGorden, Kelly M.
2008-01-01
Bioelectrical impedance analysis (BIA) is a fast, easy to administer, and relatively inexpensive method of evaluating body composition. Due to the ease of operation, interest in using BIA to estimate percentage of body fat (%BF) has grown, especially in settings where body composition assessments are often performed without the benefit of…
Reducing Uncertainties in Hydrocarbon Prediction through Application of Elastic Domain
NASA Astrophysics Data System (ADS)
Shamsuddin, S. Z.; Hermana, M.; Ghosh, D. P.; Salim, A. M. A.
2017-10-01
The application of lithology and fluid indicators has helped the geophysicists to discriminate reservoirs to non-reservoirs from a field. This analysis is conducted to select the most suitable lithology and fluid indicator for the Malaysian basins that could lead to better eliminate pitfalls of amplitude. This paper uses different rock physics analysis such as elastic impedance, Lambda-Mu-Rho, and SQp-SQs attribute. Litho-elastic impedance log is generated by correlating the gamma ray log with extended elastic impedance log. The same application is used for fluid-elastic impedance by correlation of EEI log with water saturation or resistivity. The work is done on several well logging data collected from different fields in Malay basin and its neighbouring basin. There's an excellent separation between hydrocarbon sand and background shale for Well-1 from different cross-plot analysis. Meanwhile, the Well-2 shows good separation in LMR plot. The similar method is done on the Well-3 shows fair separation of silty sand and gas sand using SQp-SQs attribute which can be correlated with well log. Based on the point distribution histogram plot, different lithology and fluid can be separated clearly. Simultaneous seismic inversion results in acoustic impedance, Vp/Vs, SQp, and SQs volumes. There are many attributes available in the industry used to separate the lithology and fluid, however some of the methods are not suitable for the application to the basins in Malaysia.
Automated analysis of plethysmograms for functional studies of hemodynamics
NASA Astrophysics Data System (ADS)
Zatrudina, R. Sh.; Isupov, I. B.; Gribkov, V. Yu.
2018-04-01
The most promising method for the quantitative determination of cardiovascular tone indicators and of cerebral hemodynamics indicators is the method of impedance plethysmography. The accurate determination of these indicators requires the correct identification of the characteristic points in the thoracic impedance plethysmogram and the cranial impedance plethysmogram respectively. An algorithm for automatic analysis of these plethysmogram is presented. The algorithm is based on the hard temporal relationships between the phases of the cardiac cycle and the characteristic points of the plethysmogram. The proposed algorithm does not require estimation of initial data and selection of processing parameters. Use of the method on healthy subjects showed a very low detection error of characteristic points.
NASA Astrophysics Data System (ADS)
Choi, Jongwan; Kim, Felix Sunjoo
2018-03-01
We studied the influence of photoanode thickness on the photovoltaic characteristics and impedance responses of the dye-sensitized solar cells based on a ruthenium dye containing a hexyloxyl-substituted carbazole unit (Ru-HCz). As the thickness of photoanode increases from 4.2 μm to 14.8 μm, the dye-loading amount and the efficiency increase. The device with thicker photoanode shows a decrease in the efficiency due to the higher probability of recombination of electron-hole pairs before charge extraction. We also analyzed the electron-transfer and recombination characteristics as a function of photoanode thickness through detailed electrochemical impedance spectroscopy analysis.
NASA Astrophysics Data System (ADS)
Schultz, A.; Bonner, L. R., IV
2017-12-01
Current efforts to assess risk to the power grid from geomagnetic disturbances (GMDs) that result in geomagnetically induced currents (GICs) seek to identify potential "hotspots," based on statistical models of GMD storm scenarios and power distribution grounding models that assume that the electrical conductivity of the Earth's crust and mantle varies only with depth. The NSF-supported EarthScope Magnetotelluric (MT) Program operated by Oregon State University has mapped 3-D ground electrical conductivity structure across more than half of the continental US. MT data, the naturally occurring time variations in the Earth's vector electric and magnetic fields at ground level, are used to determine the MT impedance tensor for each site (the ratio of horizontal vector electric and magnetic fields at ground level expressed as a complex-valued frequency domain quantity). The impedance provides information on the 3-D electrical conductivity structure of the Earth's crust and mantle. We demonstrate that use of 3-D ground conductivity information significantly improves the fidelity of GIC predictions over existing 1-D approaches. We project real-time magnetic field data streams from US Geological Survey magnetic observatories into a set of linear filters that employ the impedance data and that generate estimates of ground level electric fields at the locations of MT stations. The resulting ground electric fields are projected to and integrated along the path of power transmission lines. This serves as inputs to power flow models that represent the power transmission grid, yielding a time-varying set of quasi-real-time estimates of reactive power loss at the power transformers that are critical infrastructure for power distribution. We demonstrate that peak reactive power loss and hence peak risk for transformer damage from GICs does not necessarily occur during peak GMD storm times, but rather depends on the time-evolution of the polarization of the GMD's inducing fields and the complex ground (3-D) electric field response, and the resulting alignment of the ground electric fields with the power transmission line paths. This is informing our efforts to provide a set of real-time tools for power grid operators to use in mitigating damage from space weather events.
Susloparova, A; Koppenhöfer, D; Vu, X T; Weil, M; Ingebrandt, S
2013-02-15
In this study, impedance spectroscopy measurements of silicon-based open-gate field-effect transistor (FET) devices were utilized to study the adhesion status of cancer cells at a single cell level. We developed a trans-impedance amplifier circuit for the FETs with a higher bandwidth compared to a previously described system. The new system was characterized with a fast lock-in amplifier, which enabled measuring of impedance spectra up to 50 MHz. We studied cellular activities, including cell adhesion and anti-cancer drug induced apoptosis of human embryonic kidney (HEK293) and human lung adenocarcinoma epithelial (H441) cells. A well-known chemotherapeutic drug, topotecan hydrochloride, was used to investigate the effect of this drug to tumor cells cultured on the FET devices. The presence of the drug resulted in a 20% change in the amplitude of the impedance spectra at 200 kHz as a result of the induced apoptosis process. Real-time impedance measurements were performed inside an incubator at a constant frequency. The experimental results can be interpreted with an equivalent electronic circuit to resolve the influence of the system parameters. The developed method could be applied for the analysis of the specificity and efficacy of novel anti-cancer drugs in cancer therapy research on a single cell level in parallelized measurements. Copyright © 2012 Elsevier B.V. All rights reserved.
Ehrensberger, Mark T; Gilbert, Jeremy L
2010-05-01
The measurement of electrochemical impedance is a valuable tool to assess the electrochemical environment that exists at the surface of metallic biomaterials. This article describes the development and validation of a new technique, potential step impedance analysis (PSIA), to assess the electrochemical impedance of materials whose interface with solution can be modeled as a simplified Randles circuit that is modified with a constant phase element. PSIA is based upon applying a step change in voltage to a working electrode and analyzing the subsequent current transient response in a combined time and frequency domain technique. The solution resistance, polarization resistance, and interfacial capacitance are found directly in the time domain. The experimental current transient is numerically transformed to the frequency domain to determine the constant phase exponent, alpha. This combined time and frequency approach was tested using current transients generated from computer simulations, from resistor-capacitor breadboard circuits, and from commercially pure titanium samples immersed in phosphate buffered saline and polarized at -800 mV or +1000 mV versus Ag/AgCl. It was shown that PSIA calculates equivalent admittance and impedance behavior over this range of potentials when compared to standard electrochemical impedance spectroscopy. This current transient approach characterizes the frequency response of the system without the need for expensive frequency response analyzers or software. Copyright 2009 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Castaneda-Lopez, Homero
A methodology for detecting and locating defects or discontinuities on the outside covering of coated metal underground pipelines subjected to cathodic protection has been addressed. On the basis of wide range AC impedance signals for various frequencies applied to a steel-coated pipeline system and by measuring its corresponding transfer function under several laboratory simulation scenarios, a physical laboratory setup of an underground cathodic-protected, coated pipeline was built. This model included different variables and elements that exist under real conditions, such as soil resistivity, soil chemical composition, defect (holiday) location in the pipeline covering, defect area and geometry, and level of cathodic protection. The AC impedance data obtained under different working conditions were used to fit an electrical transmission line model. This model was then used as a tool to fit the impedance signal for different experimental conditions and to establish trends in the impedance behavior without the necessity of further experimental work. However, due to the chaotic nature of the transfer function response of this system under several conditions, it is believed that non-deterministic models based on pattern recognition algorithms are suitable for field condition analysis. A non-deterministic approach was used for experimental analysis by applying an artificial neural network (ANN) algorithm based on classification analysis capable of studying the pipeline system and differentiating the variables that can change impedance conditions. These variables include level of cathodic protection, location of discontinuities (holidays), and severity of corrosion. This work demonstrated a proof-of-concept for a well-known technique and a novel algorithm capable of classifying impedance data for experimental results to predict the exact location of the active holidays and defects on the buried pipelines. Laboratory findings from this procedure are promising, and efforts to develop it for field conditions should continue.
NASA Astrophysics Data System (ADS)
Kang, Yoon-Tae; Kim, Min-Ji; Cho, Young-Ho
2018-04-01
We present a cell impedance measurement chip capable of characterizing the toxic response of cells depending on the velocity of the supplied toxic fluid. Previous impedance-based devices using a single open-top chamber have been limited to maintaining a constant supply velocity, and devices with a single closed-top chamber present difficulties in simultaneous cytotoxicity assay for varying levels of supply velocities. The present device, capable of generating constant and multiple levels of toxic fluid velocity simultaneously within a single stepwise microchannel, performs a cytotoxicity assay dependent on toxic fluid velocity, in order to find the effective velocity of toxic fluid to cells for maximizing the cytotoxic effect. We analyze the cellular toxic response of 5% ethanol media supplied to cancer cells within a toxic fluid velocity range of 0-8.3 mm s-1. We observe the velocity-dependent cell detachment rate, impedance, and death rate. We find that the cell detachment rate decreased suddenly to 2.4% at a velocity of 4.4 mm s-1, and that the change rates of cell resistance and cell capacitance showed steep decreases to 8% and 41%, respectively, at a velocity of 5.7 mm s-1. The cell death rate and impedance fell steeply to 32% at a velocity of 5.7 mm s-1. We conclude that: (1) the present device is useful in deciding on the toxic fluid velocity effective to cytotoxicity assay, since the cellular toxic response is dependent on the velocity of toxic fluid, and; (2) the cell impedance analysis facilitates a finer cellular response analysis, showing better correlation with the cell death rate, compared to conventional visual observation. The present device, capable of performing the combinational analysis of toxic fluid velocity and cell impedance, has potential for application to the fine cellular toxicity assay of drugs with proper toxic fluid velocity.
Järverud, K; Ollmar, S; Brodin, L A
2002-09-01
Modern pacemakers (implantable devices used for maintaining an appropriate heart rate in patients) can use an intracardiac ventricular impedance signal for physiological cardiac stimulation control. Intracardiac ventricular impedance from nine animal subjects is analysed and presented (seven sheep: 49.0 +/- 6.5 kg, sinus rhythm 100.3 +/- 16.5 beats min(-1), average impedance 629.8 +/- 72.6 ohms; and two dogs: 30 kg each, sinus rhythm 86.0 beats min(-1), 862.1 ohms and 134.0 beats min(-1), 1114.6 ohms, respectively). The averaged curve and standard deviation curve of the impedance in sinus rhythm were analysed in MATLAB to clarify and study consistent impedance shape over one heart cycle. In eight of nine (89%) animal subjects, a consistent impedance slope change (notch) was observed in the early stage of the cardiac filling phase. This result was reproduced in an additional subject with simultaneous echocardiographical measurements of mitral valve blood flow. The notch occured soon after rapid early filling (E-wave in mitral flow) but prior to ventricular filling caused by atrial contraction, indicating that the impedance notch was caused by rapid ventricular filling and that it might be a sensed feature of diagnostic value. The intracardiac impedance notch in the present study had similar features to the non-invasive transthoracic impedance O-wave reported by others, and it is shown here that an O-wave is found in intracardiac impedance signals, strongly suggesting that the non-invasive O-wave is caused by cardiac events.
Triatominae-Trypanosoma cruzi/T. rangeli: Vector-parasite interactions.
Vallejo, G A; Guhl, F; Schaub, G A
2009-01-01
Of the currently known 140 species in the family Reduviidae, subfamily Triatominae, those which are most important as vectors of the aetiologic agent of Chagas disease, Trypanosoma cruzi, belong to the tribes Triatomini and Rhodniini. The latter not only transmit T. cruzi but also Trypanosoma rangeli, which is considered apathogenic for the mammalian host but can be pathogenic for the vectors. Using different molecular methods, two main lineages of T. cruzi have been classified, T. cruzi I and T. cruzi II. Within T. cruzi II, five subdivisions are recognized, T. cruzi IIa-IIe, according to the variability of the ribosomal subunits 24Salpha rRNA and 18S rRNA. In T. rangeli, differences in the organization of the kinetoplast DNA separate two forms denoted T. rangeli KP1+ and KP1-, although differences in the intergenic mini-exon gene and of the small subunit rRNA (SSU rRNA) suggest four subpopulations denoted T. rangeli A, B, C and D. The interactions of these subpopulations of the trypanosomes with different species and populations of Triatominae determine the epidemiology of the human-infecting trypanosomes in Latin America. Often, specific subpopulations of the trypanosomes are transmitted by specific vectors in a particular geographic area. Studies centered on trypanosome-triatomine interaction may allow identification of co-evolutionary processes, which, in turn, could consolidate hypotheses of the evolution and the distribution of T. cruzi/T. rangeli-vectors in America, and they may help to identify the mechanisms that either facilitate or impede the transmission of the parasites in different vector species. Such mechanisms seem to involve intestinal bacteria, especially the symbionts which are needed by the triatomines to complete nymphal development and to produce eggs. Development of the symbionts is regulated by the vector. T. cruzi and T. rangeli interfere with this system and induce the production of antibacterial substances. Whereas T. cruzi is only subpathogenic for the insect host, T. rangeli strongly affects species of the genus Rhodnius and this pathogenicity seems based on a reduction of the number of symbionts.
Hocum, Jonah D; Battrell, Logan R; Maynard, Ryan; Adair, Jennifer E; Beard, Brian C; Rawlings, David J; Kiem, Hans-Peter; Miller, Daniel G; Trobridge, Grant D
2015-07-07
Analyzing the integration profile of retroviral vectors is a vital step in determining their potential genotoxic effects and developing safer vectors for therapeutic use. Identifying retroviral vector integration sites is also important for retroviral mutagenesis screens. We developed VISA, a vector integration site analysis server, to analyze next-generation sequencing data for retroviral vector integration sites. Sequence reads that contain a provirus are mapped to the human genome, sequence reads that cannot be localized to a unique location in the genome are filtered out, and then unique retroviral vector integration sites are determined based on the alignment scores of the remaining sequence reads. VISA offers a simple web interface to upload sequence files and results are returned in a concise tabular format to allow rapid analysis of retroviral vector integration sites.
Using impedance cardiography with postural change to stratify patients with hypertension.
DeMarzo, Arthur P
2011-06-01
Early detection of cardiovascular disease in patients with hypertension could initiate appropriate treatment to control blood pressure and prevent the progression of cardiovascular disease. The goal of this study was to show how impedance cardiography waveform analysis with postural change can be used to detect subclinical cardiovascular disease in patients with high blood pressure. Patients with high blood pressure had impedance cardiography data obtained in two positions, standing upright and supine. In 50 adults, impedance cardiography indicated that all patients had abnormal data, with 44 (88%) having multiple abnormalities. Impedance cardiography showed 32 (64%) had ventricular dysfunction, 48 (96%) had vascular load abnormalities, 34 (68%) had hemodynamic abnormalities, 2 (4%) had hypovolemia, and 3 (6%) had hypervolemia. Hypertensive patients have diverse cardiovascular abnormalities that can be quantified by impedance cardiography. By stratifying patients with ventricular, vascular, and hemodynamic abnormalities, treatment could be customized based on the abnormal underlying mechanisms with the potential to rapidly control blood pressure, prevent progression of cardiovascular disease, and possibly reverse remodeling.
Finite difference time domain implementation of surface impedance boundary conditions
NASA Technical Reports Server (NTRS)
Beggs, John H.; Luebbers, Raymond J.; Yee, Kane S.; Kunz, Karl S.
1991-01-01
Surface impedance boundary conditions are employed to reduce the solution volume during the analysis of scattering from lossy dielectric objects. In the finite difference solution, they also can be utilized to avoid using small cells, made necessary by shorter wavelengths in conducting media throughout the solution volume. The standard approach is to approximate the surface impedance over a very small bandwidth by its value at the center frequency, and then use that result in the boundary condition. Here, two implementations of the surface impedance boundary condition are presented. One implementation is a constant surface impedance boundary condition and the other is a dispersive surface impedance boundary condition that is applicable over a very large frequency bandwidth and over a large range of conductivities. Frequency domain results are presented in one dimension for two conductivity values and are compared with exact results. Scattering width results from an infinite square cylinder are presented as a two dimensional demonstration. Extensions to three dimensions should be straightforward.
Finite difference time domain implementation of surface impedance boundary conditions
NASA Technical Reports Server (NTRS)
Beggs, John H.; Luebbers, Raymond J.; Yee, Kane S.; Kunz, Karl S.
1991-01-01
Surface impedance boundary conditions are employed to reduce the solution volume during the analysis of scattering from lossy dielectric objects. In a finite difference solution, they also can be utilized to avoid using small cells, made necessary by shorter wavelengths in conducting media throughout the solution volume. The standard approach is to approximate the surface impedance over a very small bandwidth by its value at the center frequency, and then use that result in the boundary condition. Two implementations of the surface impedance boundary condition are presented. One implementation is a constant surface impedance boundary condition and the other is a dispersive surface impedance boundary condition that is applicable over a very large frequency bandwidth and over a large range of conductivities. Frequency domain results are presented in one dimension for two conductivity values and are compared with exact results. Scattering width results from an infinite square cylinder are presented as a 2-D demonstration. Extensions to 3-D should be straightforward.
Aufderheide, Tom P; Pirrallo, Ronald G; Provo, Terry A; Lurie, Keith G
2005-04-01
To determine whether an impedance threshold device, designed to enhance circulation, would increase acute resuscitation rates for patients in cardiac arrest receiving conventional manual cardiopulmonary resuscitation. Prospective, randomized, double-blind, intention-to-treat. Out-of-hospital trial conducted in the Milwaukee, WI, emergency medical services system. Adults in cardiac arrest of presumed cardiac etiology. On arrival of advanced life support, patients were treated with standard cardiopulmonary resuscitation combined with either an active or a sham impedance threshold device. We measured safety and efficacy of the impedance threshold device; the primary end point was intensive care unit admission. Statistical analyses performed included the chi-square test and multivariate regression analysis. One hundred sixteen patients were treated with a sham impedance threshold device, and 114 patients were treated with an active impedance threshold device. Overall intensive care unit admission rates were 17% with the sham device vs. 25% in the active impedance threshold device (p = .13; odds ratio, 1.64; 95% confidence interval, 0.87, 3.10). Patients in the subgroup presenting with pulseless electrical activity had intensive care unit admission and 24-hr survival rates of 20% and 12% in sham (n = 25) vs. 52% and 30% in active impedance threshold device groups (n = 27) (p = .018, odds ratio, 4.31; 95% confidence interval, 1.28, 14.5, and p = .12, odds ratio, 3.09; 95% confidence interval, 0.74, 13.0, respectively). A post hoc analysis of patients with pulseless electrical activity at any time during the cardiac arrest revealed that intensive care unit and 24-hr survival rates were 20% and 11% in the sham (n = 56) vs. 41% and 27% in the active impedance threshold device groups (n = 49) (p = .018, odds ratio, 2.82; 95% confidence interval, 1.19, 6.67, and p = .037, odds ratio, 3.01; 95% confidence interval, 1.07, 8.96, respectively). There were no statistically significant differences in outcomes for patients presenting in ventricular fibrillation and asystole. Adverse event and complication rates were also similar. During this first clinical trial of the impedance threshold device during standard cardiopulmonary resuscitation, use of the new device more than doubled short-term survival rates in patients presenting with pulseless electrical activity. A larger clinical trial is underway to determine the potential longer term benefits of the impedance threshold device in cardiac arrest.
Impedance analysis of a disk-type SOFC using doped lanthanum gallate under power generation
NASA Astrophysics Data System (ADS)
Kato, Tohru; Nozaki, Ken; Negishi, Akira; Kato, Ken; Monma, Akihiko; Kaga, Yasuo; Nagata, Susumu; Takano, Kiyonami; Inagaki, Toru; Yoshida, Hiroyuki; Hosoi, Kei; Hoshino, Koji; Akbay, Taner; Akikusa, Jun
Impedance measurements were carried out under practical power generation conditions in a disk-type SOFC, which may be utilized as a small-scale power generator. The tested cell was composed of doped lanthanum gallate (La 0.8Sr 0.2Ga 0.8Mg 0.15Co 0.05O 3- δ) as the electrolyte, Sm 0.5Sr 0.5CoO 3 as the cathode electrode and Ni/Ce 0.8Sm 0.2O 2 cermet as the anode electrode. The cell impedance was measured between 10 mHz and 10 kHz by varying the fuel utilization and gas flow rate and plotted in complex impedance diagrams. The observed impedance shows a large semi-circular pattern on the low frequency side. The semi-circular impedance, having a noticeably low characteristic frequency between 0.13 and 0.4 Hz, comes from the change in gas composition, originally caused by the cell reaction. The change in impedance with the fuel utilization (load current) and the gas flow rate agreed qualitatively well with the theoretical predictions from a simulation. This impedance was dominant under high fuel-utilization power-generation conditions. The impedance, which described the activation polarizations in the electrode reactions, was comparatively small and scarcely changed with the change in fuel utilization (load current) and gas flow rate.
Angelov, Svilen D; Koenen, Sven; Jakobi, Jurij; Heissler, Hans E; Alam, Mesbah; Schwabe, Kerstin; Barcikowski, Stephan; Krauss, Joachim K
2016-01-12
Electrodes for neural stimulation and recording are used for the treatment of neurological disorders. Their features critically depend on impedance and interaction with brain tissue. The effect of surface modification on electrode impedance was examined in vitro and in vivo after intracranial implantation in rats. Electrodes coated by electrophoretic deposition with platinum nanoparticles (NP; <10 and 50 nm) as well as uncoated references were implanted into the rat's subthalamic nucleus. After postoperative recovery, rats were electrostimulated for 3 weeks. Impedance was measured before implantation, after recovery and then weekly during stimulation. Finally, local field potential was recorded and tissue-to-implant reaction was immunohistochemically studied. Coating with NP significantly increased electrode's impedance in vitro. Postoperatively, the impedance of all electrodes was temporarily further increased. This effect was lowest for the electrodes coated with particles <10 nm, which also showed the most stable impedance dynamics during stimulation for 3 weeks and the lowest total power of local field potential during neuronal activity recording. Histological analysis revealed that NP-coating did not affect glial reactions or neural cell-count. Coating with NP <10 nm may improve electrode's impedance stability without affecting biocompatibility. Increased impedance after NP-coating may improve neural recording due to better signal-to-noise ratio.
Cheng, M-F; Chen, Y-Y; Jang, T-R; Lin, W-L; Chen, J; Hsieh, K-C
2016-12-01
Standing-posture 8-electrode bioelectrical impedance analysis is a fast and practical method for evaluating body composition in clinical settings, which can be used to estimate percentage body fat (BF%) and skeletal muscle mass in a subject's total body and body segments. In this study, dual-energy X-ray absorptiometry (DXA) was used as a reference method for validating the standing 8-electrode bioelectrical impedance analysis device BC-418 (BIA 8 , Tanita Corp., Tokyo, Japan). Forty-eight Taiwanese male wrestlers aged from 17.9 to 22.3 years volunteered to participate in this study. The lean soft tissue (LST) and BF% in the total body and body segments were measured in each subject by the BIA 8 and DXA. The correlation coefficients between total body, arm, leg segments impedance index (BI, ht 2 /Z) and lean soft tissue mass measured from DXA were r = 0.902, 0.453, 0.885, respectively (p < 0.01). In addition, the total body and segmental LST estimated by the BIA 8 were highly correlated with the DXA data (r = 0.936, 0.466, 0.886, p < 0.01). The estimation of total body and segmental BF% measured by BIA 8 and DXA also showed a significant correlation (r > 0.820, p < 0.01). The estimated LST and BF% from BIA 8 in the total body and body segments were highly correlated with the DXA results, which indicated that the standing-posture 8-electrode bioelectrical impedance analysis may be used to derive reference measures of LST and BF% in Taiwanese male wrestlers.
Wideband Fully-Programmable Dual-Mode CMOS Analogue Front-End for Electrical Impedance Spectroscopy
Valente, Virgilio; Demosthenous, Andreas
2016-01-01
This paper presents a multi-channel dual-mode CMOS analogue front-end (AFE) for electrochemical and bioimpedance analysis. Current-mode and voltage-mode readouts, integrated on the same chip, can provide an adaptable platform to correlate single-cell biosensor studies with large-scale tissue or organ analysis for real-time cancer detection, imaging and characterization. The chip, implemented in a 180-nm CMOS technology, combines two current-readout (CR) channels and four voltage-readout (VR) channels suitable for both bipolar and tetrapolar electrical impedance spectroscopy (EIS) analysis. Each VR channel occupies an area of 0.48 mm2, is capable of an operational bandwidth of 8 MHz and a linear gain in the range between −6 dB and 42 dB. The gain of the CR channel can be set to 10 kΩ, 50 kΩ or 100 kΩ and is capable of 80-dB dynamic range, with a very linear response for input currents between 10 nA and 100 μA. Each CR channel occupies an area of 0.21 mm2. The chip consumes between 530 μA and 690 μA per channel and operates from a 1.8-V supply. The chip was used to measure the impedance of capacitive interdigitated electrodes in saline solution. Measurements show close matching with results obtained using a commercial impedance analyser. The chip will be part of a fully flexible and configurable fully-integrated dual-mode EIS system for impedance sensors and bioimpedance analysis. PMID:27463721
Cheng, M-F; Chen, Y-Y; Jang, T-R; Lin, W-L; Chen, J
2015-01-01
Standing-posture 8-electrode bioelectrical impedance analysis is a fast and practical method for evaluating body composition in clinical settings, which can be used to estimate percentage body fat (BF%) and skeletal muscle mass in a subject’s total body and body segments. In this study, dual-energy X-ray absorptiometry (DXA) was used as a reference method for validating the standing 8-electrode bioelectrical impedance analysis device BC-418 (BIA8, Tanita Corp., Tokyo, Japan). Forty-eight Taiwanese male wrestlers aged from 17.9 to 22.3 years volunteered to participate in this study. The lean soft tissue (LST) and BF% in the total body and body segments were measured in each subject by the BIA8 and DXA. The correlation coefficients between total body, arm, leg segments impedance index (BI, ht2/Z) and lean soft tissue mass measured from DXA were r = 0.902, 0.453, 0.885, respectively (p < 0.01). In addition, the total body and segmental LST estimated by the BIA8 were highly correlated with the DXA data (r = 0.936, 0.466, 0.886, p < 0.01). The estimation of total body and segmental BF% measured by BIA8 and DXA also showed a significant correlation (r > 0.820, p < 0.01). The estimated LST and BF% from BIA8 in the total body and body segments were highly correlated with the DXA results, which indicated that the standing-posture 8-electrode bioelectrical impedance analysis may be used to derive reference measures of LST and BF% in Taiwanese male wrestlers. PMID:28090145
Shiffman, Carl
2017-11-30
To define and elucidate the properties of reduced-variable Nyquist plots. Non-invasive measurements of the electrical impedance of the human thigh. A retrospective analysis of the electrical impedances of 154 normal subjects measured over the past decade shows that 'scaling' of the Nyquist plots for human thigh muscles is a property shared by healthy thigh musculature, irrespective of subject and the length of muscle segment. Here the term scaling signifies the near and sometimes 'perfect' coalescence of the separate X versus R plots into one 'reduced' Nyquist plot by the simple expedient of dividing R and X by X m , the value of X at the reactance maximum. To the extent allowed by noise levels one can say that there is one 'universal' reduced Nyquist plot for the thigh musculature of healthy subjects. There is one feature of the Nyquist curves which is not 'universal', however, namely the frequency f m at which the maximum in X is observed. That is found to vary from 10 to 100 kHz. depending on subject and segment length. Analysis shows, however, that the mean value of 1/f m is an accurately linear function of segment length, though there is a small subject-to-subject random element as well. Also, following the recovery of an otherwise healthy victim of ankle fracture demonstrates the clear superiority of measurements above about 800 kHz, where scaling is not observed, in contrast to measurements below about 400 kHz, where scaling is accurately obeyed. The ubiquity of 'scaling' casts new light on the interpretation of impedance results as they are used in electrical impedance myography and bioelectric impedance analysis.
Analysis of a disk-type piezoelectric ultrasonic motor using impedance matrices.
Kim, Young H; Ha, Sung K
2003-12-01
The dynamic behavior and the performance characteristics of the disk-type traveling wave piezoelectric ultrasonic motors (USM) are analyzed using impedance matrices. The stator is divided into three coupled subsystems: an inner metal disk, a piezoelectric annular actuator with segmented electrodes, and an outer metal disk with teeth. The effects of both shear deformation and rotary inertia are taken into account in deriving an impedance matrix for the piezoelectric actuator. The impedance matrices for each subsystem then are combined into a global impedance matrix using continuity conditions at the interfaces. A comparison is made between the impedance matrix model and the three-dimensional finite element model of the piezoelectric stator, obtaining the resonance and antiresonance frequencies and the effective electromechanical coupling factors versus circumferential mode numbers. Using the calculated resonance frequency and the vibration modes for the stator and a brush model with the Coulomb friction for the stator and rotor contact, stall torque, and no-load speed versus excitation frequencies are calculated at different preloads. Performance characteristics such as speed-torque curve and the output efficiency of the USM also are estimated using the current impedance matrix and the contact model. The present impedance model can be shown to be very effective in the design of the USM.
NASA Astrophysics Data System (ADS)
Kanti Bera, Tushar
2018-03-01
Biological tissues are developed with biological cells which exhibit complex electrical impedance called electrical bioimpedance. Under an alternating electrical excitation the bioimpedance varies with the tissue anatomy, composition and the signal frequency. The current penetration and conduction paths vary with frequency of the applied signal. Bioimpedance spectroscopy is used to study the frequency response of the electrical impedance of biological materials noninvasively. In bioimpedance spectroscopy, a low amplitude electrical signal is injected to the tissue sample or body parts to characterization the sample in terms of its bioimpedance. The electrical current conduction phenomena, which is highly influenced by the tissue impedance and the signal frequency, is an important phenomena which should be studied to understand the bioimpedance techniques like bioelectrical impedance analysis (BIA), EIS, or else. In this paper the origin of bioelectrical impedance and current conduction phenomena has been reviewed to present a brief summary of bioelectrical impedance and the frequency dependent current conduction through biological tissues. Simulation studies are conducted with alternation current injection through a two dimensional model of biological tissues containing finite number of biological cells suspended in extracellular fluid. The paper demonstrates the simulation of alternating current conduction through biological tissues conducted by COMSOL Multiphysics. Simulation studies also show the frequency response of the tissue impedance for different tissue compositions.
An impedance analysis of double-stream interaction in semiconductors
NASA Technical Reports Server (NTRS)
Chen, P. W.; Durney, C. H.
1972-01-01
The electromagnetic waves propagating through a drifting semiconductor plasma are studied from a macroscopic point of view in terms of double-stream interaction. The possible existing waves (helicon waves, longitudinal waves, ordinary waves, and pseudolongitudinal waves) which depend upon the orientation of the dc external magnetic field are derived. A powerful impedance concept is introduced to investigate the wave behavior of longitudinal (space charge) waves or pseudolongitudinal waves in a semiconductor plasma. The impedances due to one- and two-carrier stream interactions were calculated theoretically.
The concept of coupling impedance in the self-consistent plasma wake field excitation
NASA Astrophysics Data System (ADS)
Fedele, R.; Akhter, T.; De Nicola, S.; Migliorati, M.; Marocchino, A.; Massimo, F.; Palumbo, L.
2016-09-01
Within the framework of the Vlasov-Maxwell system of equations, we describe the self-consistent interaction of a relativistic charged-particle beam with the surroundings while propagating through a plasma-based acceleration device. This is done in terms of the concept of coupling (longitudinal) impedance in full analogy with the conventional accelerators. It is shown that also here the coupling impedance is a very useful tool for the Nyquist-type stability analysis. Examples of specific physical situations are finally illustrated.
Electrochemical impedance analysis of perovskite–electrolyte interfaces
Li, Zhen; Mercado, Candy C.; Yang, Mengjin; ...
2017-01-31
Here, the flat band potentials and carrier densities of spin coated and sprayed MAPbI 3, FA 0.85Cs 0.15PbI 3, and MAPbBr 3 perovskite films were determined using the Mott-Schottky relation. The films developed a space charge layer and exhibited p-type conduction with carrier concentration ~ 10 16 cm -3 for spin coated films. Electrochemical impedance spectra showed typical space charge impedance at frequencies > 1 kHz with increasing capacitance < 1 kHz owing to an ion diffusion component.
Random vectors and spatial analysis by geostatistics for geotechnical applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Young, D.S.
1987-08-01
Geostatistics is extended to the spatial analysis of vector variables by defining the estimation variance and vector variogram in terms of the magnitude of difference vectors. Many random variables in geotechnology are in vectorial terms rather than scalars, and its structural analysis requires those sample variable interpolations to construct and characterize structural models. A better local estimator will result in greater quality of input models; geostatistics can provide such estimators; kriging estimators. The efficiency of geostatistics for vector variables is demonstrated in a case study of rock joint orientations in geological formations. The positive cross-validation encourages application of geostatistics tomore » spatial analysis of random vectors in geoscience as well as various geotechnical fields including optimum site characterization, rock mechanics for mining and civil structures, cavability analysis of block cavings, petroleum engineering, and hydrologic and hydraulic modelings.« less
Das, Debanjan; Shiladitya, Kumar; Biswas, Karabi; Dutta, Pranab Kumar; Parekh, Aditya; Mandal, Mahitosh; Das, Soumen
2015-12-01
The paper presents a study to differentiate normal and cancerous cells using label-free bioimpedance signal measured by electric cell-substrate impedance sensing. The real-time-measured bioimpedance data of human breast cancer cells and human epithelial normal cells employs fluctuations of impedance value due to cellular micromotions resulting from dynamic structural rearrangement of membrane protrusions under nonagitated condition. Here, a wavelet-based multiscale quantitative analysis technique has been applied to analyze the fluctuations in bioimpedance. The study demonstrates a method to classify cancerous and normal cells from the signature of their impedance fluctuations. The fluctuations associated with cellular micromotion are quantified in terms of cellular energy, cellular power dissipation, and cellular moments. The cellular energy and power dissipation are found higher for cancerous cells associated with higher micromotions in cancer cells. The initial study suggests that proposed wavelet-based quantitative technique promises to be an effective method to analyze real-time bioimpedance signal for distinguishing cancer and normal cells.
Rong, Y; Padron, A V; Hagerty, K J; Nelson, N; Chi, S; Keyhani, N O; Katz, J; Datta, S P A; Gomes, C; McLamore, E S
2018-04-30
Impedimetric biosensors for measuring small molecules based on weak/transient interactions between bioreceptors and target analytes are a challenge for detection electronics, particularly in field studies or in the analysis of complex matrices. Protein-ligand binding sensors have enormous potential for biosensing, but achieving accuracy in complex solutions is a major challenge. There is a need for simple post hoc analytical tools that are not computationally expensive, yet provide near real time feedback on data derived from impedance spectra. Here, we show the use of a simple, open source support vector machine learning algorithm for analyzing impedimetric data in lieu of using equivalent circuit analysis. We demonstrate two different protein-based biosensors to show that the tool can be used for various applications. We conclude with a mobile phone-based demonstration focused on the measurement of acetone, an important biomarker related to the onset of diabetic ketoacidosis. In all conditions tested, the open source classifier was capable of performing as well as, or better, than the equivalent circuit analysis for characterizing weak/transient interactions between a model ligand (acetone) and a small chemosensory protein derived from the tsetse fly. In addition, the tool has a low computational requirement, facilitating use for mobile acquisition systems such as mobile phones. The protocol is deployed through Jupyter notebook (an open source computing environment available for mobile phone, tablet or computer use) and the code was written in Python. For each of the applications, we provide step-by-step instructions in English, Spanish, Mandarin and Portuguese to facilitate widespread use. All codes were based on scikit-learn, an open source software machine learning library in the Python language, and were processed in Jupyter notebook, an open-source web application for Python. The tool can easily be integrated with the mobile biosensor equipment for rapid detection, facilitating use by a broad range of impedimetric biosensor users. This post hoc analysis tool can serve as a launchpad for the convergence of nanobiosensors in planetary health monitoring applications based on mobile phone hardware.
Maioli, Mauro; Toso, Anna; Leoncini, Mario; Musilli, Nicola; Bellandi, Francesco; Rosner, Mitchell H; McCullough, Peter A; Ronco, Claudio
2014-04-15
The aim of this study was to evaluate the relationship between pre-procedural fluid status assessed by bioimpedance vector analysis (BIVA) and development of contrast-induced acute kidney injury (CI-AKI). Accurate fluid management in patients undergoing angiographic procedures is of critical importance in limiting the risk of CI-AKI. Therefore, establishing peri-procedural fluid volume related to increased risk of CI-AKI development is essential. We evaluated the fluid status by BIVA of 900 consecutive patients with stable coronary artery disease (CAD) immediately before coronary angiography, measuring the resistance/height (R/H) ratio and impedance/height (Z/H) vector. CI-AKI was defined as an increase in serum creatinine ≥0.5 mg/dl above baseline within 3 days after contrast administration (iodixanol). CI-AKI occurred in 54 patients (6.0%). Pre-procedural R/H ratios were significantly higher in patients with CI-AKI than without CI-AKI (395 ± 71 Ohm/m vs. 352 ± 58 Ohm/m, p = 0.001 for women; 303 ± 59 Ohm/m vs. 279 ± 45 Ohm/m, p = 0.009 for men), indicating lower fluid volume in the patients with CI-AKI. When patients were stratified according to R/H ratio, there was an almost 3-fold higher risk in patients with higher values (odds ratio [OR]: 2.9; 95% confidence interval [CI]: 1.5 to 5.5; p = 0.002). The optimal receiver-operating characteristic curve analysis threshold values of R/H ratio for predicting CI-AKI were 380 Ohm/m for women and 315 Ohm/m for men. R/H ratio above these thresholds was found to be a significant and independent predictor of CI-AKI (OR: 3.1; 95% CI: 1.8 to 5.5; p = 0.001). Lower fluid status evaluated by BIVA immediately before contrast medium administration resulted in a significant and independent predictor of CI-AKI in patients with stable CAD. This simple noninvasive analysis should be tested in guiding tailored volume repletion. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
de Freitas Junior, Wilson Rodrigues; Ilias, Elias Jirjoss; Kassab, Paulo; Cordts, Roberto; Porto, Paulo Gustavo; Martins Rodrigues, Francisco Cesar; Ali Taha, Mohamed Ibrahim; Carrara, Paulo; de Carvalho Aguiar, Isabella; de Oliveira, Luis Vicente Franco; Malheiros, Carlos Alberto
2014-01-01
Background. Bariatric surgery is considered an effective option for the management of morbid obesity. The incidence of obesity has been gradually increasing all over the world reaching epidemic proportions in some regions of the world. Obesity can cause a reduction of up to 22% in the life expectancy of morbidly obese patients. Objective. The objective of this paper is to assess the weight loss associated with the first 6 months after bariatric surgery using bioelectric impedance analysis (BIA) for the evaluation of fat mass and fat-free mass. Method. A total of 36 morbidly obese patients were subjected to open gastric bypass surgery. The patients weight was monitored before and after the procedure using the bioelectric impedance analysis. Results. Bariatric surgery resulted in an average percentage of weight loss of 28.6% (40 kg) as determined 6 months after the procedure was performed. Analysis of the different components of body weight indicated an undesirable loss of fat-free mass along with the reduction of total body weight. Conclusion. Open gastric bypass induced a significant loss of total weight and loss of fat-free mass in patients six months after the surgery. The use of bioelectric impedance analysis resulted in an appropriate estimation of the total weight components in individuals subjected to bariatric surgery allowing a more real analysis of the variation of weight after the surgery. PMID:24523649
Lovelady, Douglas C.; Friedman, Jennifer; Patel, Sonali; Rabson, David A.; Lo, Chun-Min
2009-01-01
We performed micromotion experiments using electric cell-substrate impedance sensing (ECIS) on a confluent layer of 3T3 fibroblasts exposed to different low levels of the toxin cytochalasin B. This toxin is know to affect actin polymerization and to disrupt cytoskeletal structure and function in cells, changing the morphology of confluent cell cultures and altering the nature of the cellular micromotion, which is measured by ECIS as changes in impedance. By looking at several measures to characterize the long- and short-term correlations in the noise of the impedance time series, we are able to detect the effects of the toxin at concentrations down to 1 μM; there are intriguing hints that the effects may be discernible at levels as low as 0.1 μM. These measures include the power spectrum, the Hurst and detrended-fluctuation-analysis exponents, and the first zero and first 1/e crossings of the autocorrelation function. While most published work with ECIS uses only average impedance values, we demonstrate that noise analysis provides a more sensitive probe. PMID:19026529
Self-healing bolted joint employing a shape memory actuator
NASA Astrophysics Data System (ADS)
Muntges, Daniel E.; Park, Gyuhae; Inman, Daniel J.
2001-08-01
This paper is a report of an initial investigation into the active control of preload in the joint using a shape memory actuator around the axis of the bolt shaft. Specifically, the actuator is a cylindrical Nitinol washer that expands axially when heated, according to the shape memory effect. The washer is actuated in response to an artificial decrease in torque. Upon actuation, the stress generated by its axial strain compresses the bolted members and creates a frictional force that has the effect of generating a preload and restoring lost torque. In addition to torque wrenches, the system in question was monitored in all stages of testing using piezoelectric impedance analysis. Impedance analysis drew upon research techniques developed at Center for Intelligent Material Systems and Structures, in which phase changes in the impedance of a self-sensing piezoceramic actuator correspond to changes in joint stiffness. Through experimentation, we have documented a successful actuation of the shape memory element. Due to complexity of constitutive modeling, qualitative analysis by the impedance method is used to illustrate the success. Additional considerations encountered in this initial investigation are made to guide further thorough research required for the successful commercial application of this promising technique.
Cho, Y K; Choi, M-G; Oh, S N; Baik, C N; Park, J M; Lee, I S; Kim, S W; Choi, K Y; Chung, I-S
2012-01-01
Bolus transit through the esophagus has not been validated by videoesophagram in patients with dysphagia and changes in impedance with abnormal barium transit have not been described in those patients. The aim of this study was to compare esophageal impedance findings with barium esophagram measurements in patients with dysphagia. The consecutive patients with dysphagia underwent conventional multichannel esophageal impedance manometry, after which a barium videoesophagram was performed simultaneously with multichannel esophageal impedance manometry using a mean of three swallows of barium. Esophageal emptying patterns shown in the esophagogram were classified by the degree of intraesophageal stasis and presence of intraesophageal reflux. Bolus transit patterns in impedance were classified as complete and incomplete transit. Sixteen patients (M : F = 8 : 8, mean age, 47 years) were enrolled. Their manometric diagnosis were normal (n= 6), ineffective esophageal motility (n= 1), diffuse esophageal spasm (DES; n= 2), and achalasia (n= 7). Sixty-three swallows were analyzed. According to impedance analysis, 21/22 swallows with normal barium emptying showed complete transit (96%) and 31/32 swallows with severe stasis showed incomplete transit (97%). Nine swallows with mild stasis showed either complete or incomplete transit patterns in impedance. Swallows with mild barium stasis and complete transit in impedance were observed in patients who had received treatment (two patients with achalasia with history of esophageal balloonplasty and a patient with DES after nifedipine administration). Impedance reflected severe stasis with retrograde barium movement and described typical bolus transit patterns in patients with achalasia and DES. In conclusion, impedance-barium esophagram concordance is high for swallows with normal esophageal emptying and for severe barium stasis in patients with dysphagia. © 2011 Copyright the Authors. Journal compilation © 2011, Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.
Step voltage analysis for the catenoid lightning protection system
NASA Technical Reports Server (NTRS)
Chai, J. C.; Briet, R.; Barker, D. L.; Eley, H. E.
1991-01-01
The main objective of the proposed overhead Catenoid Lightning Protection System (CLPS) is personnel safety. To ensure working personnel's safety in lightning situations, it is necessary that the potential difference developed across a distance equal to a person's pace (step voltage) does not exceed a separately established safe voltage in order to avoid electrocution (ventricular fibrillation) of humans. Therefore, the first stage of the analytical effort is to calculate the open circuit step voltage. An impedance model is developed for this purpose. It takes into consideration the earth's complex impedance behavior and the transient nature of the lightning phenomenon. In the low frequency limit, this impedance model is shown to reduce to results similar to those predicted by the conventional resistor model in a DC analysis.
NASA Technical Reports Server (NTRS)
Rick, R. C.; Lushbaugh, C. C.; Mcdow, E.; Frome, E.
1972-01-01
Changes in respiratory variance revealed by power spectral analysis of the pulmonary impedance pneumogram can be used to detect and measure stresses directly or indirectly affecting human respiratory function. When gastrointestinal distress occurred during a series of 5 total-body exposures of 30 R at a rate of 1.5 R/min, it was accompanied by typical shifts in pulmonary impedance power spectra. These changes did not occur after protracted exposure of 250 R (30 R daily) at 1.5 R/hr that failed to cause radiation sickness. This system for quantitating respiratory effort can also be used to detect alterations in one's ability to perform under controlled exercise conditions.
Development and Validation of an Interactive Liner Design and Impedance Modeling Tool
NASA Technical Reports Server (NTRS)
Howerton, Brian M.; Jones, Michael G.; Buckley, James L.
2012-01-01
The Interactive Liner Impedance Analysis and Design (ILIAD) tool is a LabVIEW-based software package used to design the composite surface impedance of a series of small-diameter quarter-wavelength resonators incorporating variable depth and sharp bends. Such structures are useful for packaging broadband acoustic liners into constrained spaces for turbofan engine noise control applications. ILIAD s graphical user interface allows the acoustic channel geometry to be drawn in the liner volume while the surface impedance and absorption coefficient calculations are updated in real-time. A one-dimensional transmission line model serves as the basis for the impedance calculation and can be applied to many liner configurations. Experimentally, tonal and broadband acoustic data were acquired in the NASA Langley Normal Incidence Tube over the frequency range of 500 to 3000 Hz at 120 and 140 dB SPL. Normalized impedance spectra were measured using the Two-Microphone Method for the various combinations of channel configurations. Comparisons between the computed and measured impedances show excellent agreement for broadband liners comprised of multiple, variable-depth channels. The software can be used to design arrays of resonators that can be packaged into complex geometries heretofore unsuitable for effective acoustic treatment.
Acoustic Absorption Characteristics of an Orifice With a Mean Bias Flow
NASA Technical Reports Server (NTRS)
Ahuja, K. K.; Gaeta, R. J., Jr.; DAgostino, M.; Jones, Mike (Technical Monitor)
2000-01-01
The objective of the study reported here was to acquire acoustic and flow data for numerical validation of impedance models that simulate bias flow through perforates. The impedance model is being developed by researchers at High Technology Corporation. This report documents normal incidence impedance measurements a singular circular orifice with mean flow passing through it. All measurements are made within a 1.12 inch (28.5 mm) diameter impedance tube. The mean flow is introduced upstream of the orifice (with the flow and incident sound wave travelling in the same direction) with an anechoic termination downstream of the orifice. Velocity profiles are obtained upstream of the orifice to characterize the inflow boundary conditions. Velocity in the center of the orifice is also obtained. All velocity measurements are made with a hot wire anemometer and subsequent checked with mass flow measurements made concurrently. All impedance measurements are made using the Two-Microphone Method. Although we have left the analysis of the data to the developers of the impedance models that simulate bias flow through perforate, our initial examination indicates that our results follow the trends consistent with published theory on impedance of perforates with a steady bias flow.
Bioelectrical Impedance and Body Composition Assessment
ERIC Educational Resources Information Center
Martino, Mike
2006-01-01
This article discusses field tests that can be used in physical education programs. The most common field tests are anthropometric measurements, which include body mass index (BMI), girth measurements, and skinfold testing. Another field test that is gaining popularity is bioelectrical impedance analysis (BIA). Each method has particular strengths…
Eliminating the η-problem in SUGRA hybrid inflation with vector backreaction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dimopoulos, Konstantinos; Wagstaff, Jacques M.; Lazarides, George, E-mail: k.dimopoulos1@lancaster.ac.uk, E-mail: lazaride@eng.auth.gr, E-mail: j.wagstaff@lancaster.ac.uk
2012-02-01
It is shown that, when the inflaton field modulates the gauge kinetic function of the gauge fields in supergravity realisations of inflation, the dynamic backreaction leads to a new inflationary attractor solution, in which the inflaton's variation suffers additional impedance. As a result, slow-roll inflation can naturally occur along directions of the scalar potential which would be too steep and curved to support it otherwise. This provides a generic solution to the infamous eta-problem of inflation in supergravity. Moreover, it is shown that, in the new inflationary attractor, the spectral index of the generated curvature perturbations is kept mildly redmore » despite eta of order unity. The above findings are applied to a model of hybrid inflation in supergravity with a generic Kähler potential. The spectral index of the generated curvature perturbations is found to be 0.97–0.98, in excellent agreement with observations. The gauge field can play the role of the vector curvaton after inflation but observable statistical anisotropy requires substantial tuning of the gauge coupling.« less
NASA Technical Reports Server (NTRS)
Dean, P. D.
1978-01-01
A systems concept procedure is described for the optimization of acoustic duct liner design for both uniform and multisegment types. The concept was implemented by the use of a double reverberant chamber flow duct facility coupled with sophisticated computer control and acoustic analysis systems. The optimization procedure for liner insertion loss was based on the concept of variable liner impedance produced by bias air flow through a multilayer, resonant cavity liner. A multiple microphone technique for in situ wall impedance measurements was used and successfully adapted to produce automated measurements for all liner configurations tested. The complete validation of the systems concept was prevented by the inability to optimize the insertion loss using bias flow induced wall impedance changes. This inability appeared to be a direct function of the presence of a higher order energy carrying modes which were not influenced significantly by the wall impedance changes.
Ehmler, Hartmut; Köppen, Matthias
2007-10-01
The impedance spectrum test was employed for detection of short circuits within Wendelstein 7-X (W7-X) superconducting magnetic field coils. This test is based on measuring the complex impedance over several decades of frequency. The results are compared to predictions of appropriate electrical equivalent circuits of coils in different production states or during cold test. When the equivalent circuit is not too complicated the impedance can be represented by an analytic function. A more detailed analysis is performed with a network simulation code. The overall agreement of measured and calculated or simulated spectra is good. Two types of short circuits which appeared are presented and analyzed. The detection limit of the method is discussed. It is concluded that combined high-voltage ac and low-voltage impedance spectrum tests are ideal means to rule out short circuits in the W7-X coils.
Power dissipation in fractal AC circuits
NASA Astrophysics Data System (ADS)
Chen, Joe P.; Rogers, Luke G.; Anderson, Loren; Andrews, Ulysses; Brzoska, Antoni; Coffey, Aubrey; Davis, Hannah; Fisher, Lee; Hansalik, Madeline; Loew, Stephen; Teplyaev, Alexander
2017-08-01
We extend Feynman’s analysis of an infinite ladder circuit to fractal circuits, providing examples in which fractal circuits constructed with purely imaginary impedances can have characteristic impedances with positive real part. Using (weak) self-similarity of our fractal structures, we provide algorithms for studying the equilibrium distribution of energy on these circuits. This extends the analysis of self-similar resistance networks introduced by Fukushima, Kigami, Kusuoka, and more recently studied by Strichartz et al.
NASA Astrophysics Data System (ADS)
Velraj, S.; Zhu, J. H.; Painter, A. S.; Du, S. W.; Li, Y. T.
2014-02-01
Impedance spectroscopy was used to evaluate the oxide films formed on cobalt-coated Crofer 22 APU ferritic stainless steel after thermal oxidation at 800 °C in air for different times (i.e. 2, 50, 100 and 500 h). Impedance spectra of the oxide films exhibited two or three semicircles depending on the oxidation time, which correspond to the presence of two or three individual oxide layers. Coupled with scanning electron microscopy/energy-dispersive spectroscopy (SEM/EDS) and X-ray diffraction (XRD), the individual oxide layer corresponding to each semicircle was determined unambiguously. Impedance spectrum analysis of the oxide films formed on the sample after thermal exposure at 800 °C in air for 2 h led to the identification of the low-frequency and high-frequency semicircles as being from Cr2O3 and Co3O4, respectively. SEM/EDS and XRD analysis of the 500-h sample clearly revealed the presence of three oxide layers, analyzed to be Co3-xCrxO4, CoCr2O4, and Cr2O3. Although the SEM images of the 50-h and 100-h samples did not clearly show the CoCr2O4 layer, impedance plots implied their presence. The oxide scales were assigned to their respective semicircles and the electrical properties of Co3-xCrxO4, CoCr2O4 and Cr2O3 were determined from the impedance data.
Analysis of the Impedance Resonance of Piezoelectric Multi-Fiber Composite Stacks
NASA Technical Reports Server (NTRS)
Sherrit, S.; Djrbashian, A.; Bradford, S C
2013-01-01
Multi-Fiber CompositesTM (MFC's) produced by Smart Materials Corp behave essentially like thin planar stacks where each piezoelectric layer is composed of a multitude of fibers. We investigate the suitability of using previously published inversion techniques for the impedance resonances of monolithic co-fired piezoelectric stacks to the MFCTM to determine the complex material constants from the impedance data. The impedance equations examined in this paper are those based on the derivation. The utility of resonance techniques to invert the impedance data to determine the small signal complex material constants are presented for a series of MFC's. The technique was applied to actuators with different geometries and the real coefficients were determined to be similar within changes of the boundary conditions due to change of geometry. The scatter in the imaginary coefficient was found to be larger. The technique was also applied to the same actuator type but manufactured in different batches with some design changes in the non active portion of the actuator and differences in the dielectric and the electromechanical coupling between the two batches were easily measureable. It is interesting to note that strain predicted by small signal impedance analysis is much lower than high field stains. Since the model is based on material properties rather than circuit constants, it could be used for the direct evaluation of specific aging or degradation mechanisms in the actuator as well as batch sorting and adjustment of manufacturing processes.
Desjardin, Marie; Roman, Sabine; des Varannes, Stanislas Bruley; Gourcerol, Guillaume; Coffin, Benoit; Ropert, Alain; Mion, François
2013-01-01
Background Pharyngeal pH probes and pH-impedance catheters have been developed for the diagnosis of laryngo-pharyngeal reflux. Objective To determine the reliability of pharyngeal pH alone for the detection of pharyngeal reflux events. Methods 24-h pH-impedance recordings performed in 45 healthy subjects with a bifurcated probe for detection of pharyngeal and oesophageal reflux events were reviewed. Pharyngeal pH drops to below 4 and 5 were analysed for the simultaneous occurrence of pharyngeal reflux, gastro-oesophageal reflux, and swallows, according to impedance patterns. Results Only 7.0% of pharyngeal pH drops to below 5 identified with impedance corresponded to pharyngeal reflux, while 92.6% were related to swallows and 10.2 and 13.3% were associated with proximal and distal gastro-oesophageal reflux events, respectively. Of pharyngeal pH drops to below 4, 13.2% were related to pharyngeal reflux, 87.5% were related to swallows, and 18.1 and 21.5% were associated with proximal and distal gastro-oesophageal reflux events, respectively. Conclusions This study demonstrates that pharyngeal pH alone is not reliable for the detection of pharyngeal reflux and that adding distal oesophageal pH analysis is not helpful. The only reliable analysis should take into account impedance patterns demonstrating the presence of pharyngeal reflux event preceded by a distal and proximal reflux event within the oesophagus. PMID:24917995
ac-driven vortices and the Hall effect in a superconductor with a tilted washboard pinning potential
NASA Astrophysics Data System (ADS)
Shklovskij, Valerij A.; Dobrovolskiy, Oleksandr V.
2008-09-01
The Langevin equation for a two-dimensional (2D) nonlinear guided vortex motion in a tilted cosine pinning potential in the presence of an ac is exactly solved in terms of a matrix continued fraction at arbitrary value of the Hall effect. The influence of an ac of arbitrary amplitude and frequency on the dc and ac magnetoresistivity tensors is analyzed. The ac density and frequency dependence of the overall shape and the number and position of the Shapiro steps on the anisotropic current-voltage characteristics are considered. The influence of a subcritical or overcritical dc on the time-dependent stationary ac longitudinal and transverse resistive vortex responses (on the frequency of an ac drive Ω ) in terms of the nonlinear impedance tensor Ẑ and the nonlinear ac response at Ω harmonics are studied. Analytical formulas for 2D temperature-dependent linear impedance tensor ẐL in the presence of a dc which depend on the angle α between the current-density vector and the guiding direction of the washboard planar pinning potential are derived and analyzed. Influence of α anisotropy and the Hall effect on the nonlinear power absorption by vortices is discussed.
Inverse solutions for electrical impedance tomography based on conjugate gradients methods
NASA Astrophysics Data System (ADS)
Wang, M.
2002-01-01
A multistep inverse solution for two-dimensional electric field distribution is developed to deal with the nonlinear inverse problem of electric field distribution in relation to its boundary condition and the problem of divergence due to errors introduced by the ill-conditioned sensitivity matrix and the noise produced by electrode modelling and instruments. This solution is based on a normalized linear approximation method where the change in mutual impedance is derived from the sensitivity theorem and a method of error vector decomposition. This paper presents an algebraic solution of the linear equations at each inverse step, using a generalized conjugate gradients method. Limiting the number of iterations in the generalized conjugate gradients method controls the artificial errors introduced by the assumption of linearity and the ill-conditioned sensitivity matrix. The solution of the nonlinear problem is approached using a multistep inversion. This paper also reviews the mathematical and physical definitions of the sensitivity back-projection algorithm based on the sensitivity theorem. Simulations and discussion based on the multistep algorithm, the sensitivity coefficient back-projection method and the Newton-Raphson method are given. Examples of imaging gas-liquid mixing and a human hand in brine are presented.
Jang, Hae-Won; Ih, Jeong-Guon
2012-04-01
The time domain boundary element method (BEM) is associated with numerical instability that typically stems from the time marching scheme. In this work, a formulation of time domain BEM is derived to deal with all types of boundary conditions adopting a multi-input, multi-output, infinite impulse response structure. The fitted frequency domain impedance data are converted into a time domain expression as a form of an infinite impulse response filter, which can also invoke a modeling error. In the calculation, the response at each time step is projected onto the wave vector space of natural radiation modes, which can be obtained from the eigensolutions of the single iterative matrix. To stabilize the computation, unstable oscillatory modes are nullified, and the same decay rate is used for two nonoscillatory modes. As a test example, a transient sound field within a partially lined, parallelepiped box is used, within which a point source is excited by an octave band impulse. In comparison with the results of the inverse Fourier transform of a frequency domain BEM, the average of relative difference norm in the stabilized time response is found to be 4.4%.
EIT image reconstruction with four dimensional regularization.
Dai, Tao; Soleimani, Manuchehr; Adler, Andy
2008-09-01
Electrical impedance tomography (EIT) reconstructs internal impedance images of the body from electrical measurements on body surface. The temporal resolution of EIT data can be very high, although the spatial resolution of the images is relatively low. Most EIT reconstruction algorithms calculate images from data frames independently, although data are actually highly correlated especially in high speed EIT systems. This paper proposes a 4-D EIT image reconstruction for functional EIT. The new approach is developed to directly use prior models of the temporal correlations among images and 3-D spatial correlations among image elements. A fast algorithm is also developed to reconstruct the regularized images. Image reconstruction is posed in terms of an augmented image and measurement vector which are concatenated from a specific number of previous and future frames. The reconstruction is then based on an augmented regularization matrix which reflects the a priori constraints on temporal and 3-D spatial correlations of image elements. A temporal factor reflecting the relative strength of the image correlation is objectively calculated from measurement data. Results show that image reconstruction models which account for inter-element correlations, in both space and time, show improved resolution and noise performance, in comparison to simpler image models.
NASA Astrophysics Data System (ADS)
Gopal Madhav Annamdas, Venu; Kiong Soh, Chee
2017-01-01
Continuous structural health monitoring (SHM) and delayed SHM techniques can be contact/ contactless, surface bonded/embedded, wired/wireless and active/passive actuator-sensor systems which transfer the recorded condition of the structure to the base station almost instantaneously or with time delay respectively. The time between fatal crack initiation and its propagation leading to the collapse of key infrastructures such as aerospace, nuclear facilities, oil and gas is mostly short. Timely discovery of structural problem depends heavily on the scanning period in well-established techniques like piezoelectric (PZT) based electromechanical impedance (EMI) technique. This often takes much scanning time due to the acquisition of resonant structural peaks at all frequencies in the considered bandwidth; thus poses a challenge for its implementation in practice. On the other hand, recently developed strain sensors based on metamaterials and their breeds such as nested split-ring resonators, localized surface plasmons (LSP), etc, employ measurement of reflected or transmitted signal, with super-fast scanning in the order of at most 1/100th of the time taken by the EMI technique. This paper articulates faster measurements by reducing unnecessary resonant structural peaks and focusing on rapid monitoring using PZT and metamaterial plasmons. Our research adopted wired PZT and wireless LSP communications with impedance analyser and vector network analyser respectively. We present integrated and complementary nature of these techniques, which can be processed rapidly for key infrastructures with great effectiveness. This integration can result in both continuous and delayed SHM techniques based on time or frequency or both domains.
Galluzzo, M; Talamonti, M; Perino, F; Servoli, S; Giordano, D; Chimenti, S; De Simone, C; Peris, K
2017-06-01
There is strong evidence that obesity is closely associated with psoriasis. However, data on body composition are lacking in psoriasis. The purpose of this study were to investigate the body composition in psoriasis patients using bioelectrical impedance analysis and to correlate the bioelectrical impedance data with disease severity and laboratory parameters. Anthropometric measurements and bioelectrical impedance analyses were performed on patients with psoriasis, naïve to any systemic treatment, who attended the outpatient clinics of two University centers. Data of 164 adult patients were analyzed. Compared to men, women had several significantly higher bioelectrical impedance parameters including reactance, fat mass% and adipose tissue%. The values of adipose tissue were positively correlated only with patients age (p = .021) and age at disease onset (p = .0006), but not with disease severity. In addition, we observed that the use of BMI cutoffs allowed to categorize 36.7% of women and 19.2% of men as obese, while fat mass% showed that 53.3% of women and 48.1% of men were obese. In our study, psoriasis is been associated with a high fat mass%. We suggest that screening for body fat distribution in psoriatic patients might be useful to identify early obesity-related disease.
Diagnostic criteria for mass lesions differentiating in electrical impedance mammography
NASA Astrophysics Data System (ADS)
A, Karpov; M, Korotkova
2013-04-01
The purpose of this research was to determine the diagnostic criteria for differentiating volumetric lesions in the mammary gland in electrical impedance mammography. The research was carried out utilizing the electrical impedance computer mammograph llMEIK v.5.6gg®, which enables to acquire images of 3-D conductivity distribution layers within mamma's tissues up to 5 cm depth. The weighted reciprocal projection method was employed to reconstruct the 3-D electric conductivity distribution of the examined organ. The results of 3,710 electrical impedance examinations were analyzed. The analysis of a volumetric lesion included assessment of its shape, contour, internal electrical structure and changes of the surrounding tissues. Moreover, mammary gland status was evaluated with the help of comparative and age-related electrical conductivity curves. The diagnostic chart is provided. Each criterion is measured in points. Using the numerical score for evaluation of mass and non-volumetric lesions within the mammary gland in electrical impedance mammography allowed comparing this information to BI-RADS categories developed by American College of Radiology experts. The article is illustrated with electrical impedance mammograms and tables.
New equivalent-electrical circuit model and a practical measurement method for human body impedance.
Chinen, Koyu; Kinjo, Ichiko; Zamami, Aki; Irei, Kotoyo; Nagayama, Kanako
2015-01-01
Human body impedance analysis is an effective tool to extract electrical information from tissues in the human body. This paper presents a new measurement method of impedance using armpit electrode and a new equivalent circuit model for the human body. The lowest impedance was measured by using an LCR meter and six electrodes including armpit electrodes. The electrical equivalent circuit model for the cell consists of resistance R and capacitance C. The R represents electrical resistance of the liquid of the inside and outside of the cell, and the C represents high frequency conductance of the cell membrane. We propose an equivalent circuit model which consists of five parallel high frequency-passing CR circuits. The proposed equivalent circuit represents alpha distribution in the impedance measured at a lower frequency range due to ion current of the outside of the cell, and beta distribution at a high frequency range due to the cell membrane and the liquid inside cell. The calculated values by using the proposed equivalent circuit model were consistent with the measured values for the human body impedance.
NASA Astrophysics Data System (ADS)
Li, Hui; Hong, Lu-Yao; Zhou, Qing; Yu, Hai-Jie
2015-08-01
The business failure of numerous companies results in financial crises. The high social costs associated with such crises have made people to search for effective tools for business risk prediction, among which, support vector machine is very effective. Several modelling means, including single-technique modelling, hybrid modelling, and ensemble modelling, have been suggested in forecasting business risk with support vector machine. However, existing literature seldom focuses on the general modelling frame for business risk prediction, and seldom investigates performance differences among different modelling means. We reviewed researches on forecasting business risk with support vector machine, proposed the general assisted prediction modelling frame with hybridisation and ensemble (APMF-WHAE), and finally, investigated the use of principal components analysis, support vector machine, random sampling, and group decision, under the general frame in forecasting business risk. Under the APMF-WHAE frame with support vector machine as the base predictive model, four specific predictive models were produced, namely, pure support vector machine, a hybrid support vector machine involved with principal components analysis, a support vector machine ensemble involved with random sampling and group decision, and an ensemble of hybrid support vector machine using group decision to integrate various hybrid support vector machines on variables produced from principle components analysis and samples from random sampling. The experimental results indicate that hybrid support vector machine and ensemble of hybrid support vector machines were able to produce dominating performance than pure support vector machine and support vector machine ensemble.
Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators.
Kim, Pil-Jong; Kim, Hong-Gee; Cho, Byeong-Hoon
2015-05-01
The aim of this paper was evaluating the ratios of electrical impedance measurements reported in previous studies through a correlation analysis in order to explicit it as the contributing factor to the accuracy of electronic apex locator (EAL). The literature regarding electrical property measurements of EALs was screened using Medline and Embase. All data acquired were plotted to identify correlations between impedance and log-scaled frequency. The accuracy of the impedance ratio method used to detect the apical constriction (APC) in most EALs was evaluated using linear ramp function fitting. Changes of impedance ratios for various frequencies were evaluated for a variety of file positions. Among the ten papers selected in the search process, the first-order equations between log-scaled frequency and impedance were in the negative direction. When the model for the ratios was assumed to be a linear ramp function, the ratio values decreased if the file went deeper and the average ratio values of the left and right horizontal zones were significantly different in 8 out of 9 studies. The APC was located within the interval of linear relation between the left and right horizontal zones of the linear ramp model. Using the ratio method, the APC was located within a linear interval. Therefore, using the impedance ratio between electrical impedance measurements at different frequencies was a robust method for detection of the APC.
NASA Technical Reports Server (NTRS)
Nguyen, D. T.; Al-Nasra, M.; Zhang, Y.; Baddourah, M. A.; Agarwal, T. K.; Storaasli, O. O.; Carmona, E. A.
1991-01-01
Several parallel-vector computational improvements to the unconstrained optimization procedure are described which speed up the structural analysis-synthesis process. A fast parallel-vector Choleski-based equation solver, pvsolve, is incorporated into the well-known SAP-4 general-purpose finite-element code. The new code, denoted PV-SAP, is tested for static structural analysis. Initial results on a four processor CRAY 2 show that using pvsolve reduces the equation solution time by a factor of 14-16 over the original SAP-4 code. In addition, parallel-vector procedures for the Golden Block Search technique and the BFGS method are developed and tested for nonlinear unconstrained optimization. A parallel version of an iterative solver and the pvsolve direct solver are incorporated into the BFGS method. Preliminary results on nonlinear unconstrained optimization test problems, using pvsolve in the analysis, show excellent parallel-vector performance indicating that these parallel-vector algorithms can be used in a new generation of finite-element based structural design/analysis-synthesis codes.
NASA Astrophysics Data System (ADS)
Buettel, G.; Joppich, J.; Hartmann, U.
2017-12-01
Giant magnetoimpedance (GMI) measurements in the high-frequency regime utilizing a coplanar waveguide with an integrated Permalloy multilayer and micromachined on a silicon cantilever are reported. The fabrication process is described in detail. The aspect ratio of the magnetic multilayer in the magnetoresistive and magnetostrictive device was varied. Tensile strain and compressive strain were applied. Vector network analyzer measurements in the range from the skin effect to ferromagnetic resonance confirm the technological potential of GMI-based micro-electro-mechanical devices for strain and magnetic field sensing applications. The strain-impedance gauge factor was quantified by finite element strain calculations and reaches a maximum value of almost 200.
Frazzoni, Marzio; Savarino, Edoardo; de Bortoli, Nicola; Martinucci, Irene; Furnari, Manuele; Frazzoni, Leonardo; Mirante, Vincenzo Giorgio; Bertani, Helga; Marchi, Santino; Conigliaro, Rita; Savarino, Vincenzo
2016-01-01
Analyses of impedance parameters such as the post-reflux swallow-induced peristaltic wave (PSPW) index and the mean nocturnal baseline impedance (MNBI) have been proposed to increase the accuracy of diagnosis of reflux disease. We assessed whether these improve the diagnostic yield of impedance pH monitoring of reflux disease. We performed a prospective study of consecutive patients with proton pump inhibitor-responsive heartburn who underwent 24-hour impedance pH monitoring at hospitals in Italy from January 2011 through December 2013. Reviewers blindly analyzed off-therapy impedance pH tracings from 289 patients with proton pump inhibitor-responsive heartburn, 68 with erosive reflux disease and 221 with non-erosive reflux disease (NERD), along with 50 healthy individuals (controls). The PSPW index, the MNBI, the esophageal acid exposure time, the number of total refluxes, and the bolus exposure were calculated, as well as the symptom association probability (SAP) and the symptom index (SI). In receiver operating characteristic analysis, the area under curve of the PSPW index (0.977; 95% confidence interval, 0.961-0.993) was significantly greater than that of the other impedance pH parameters in identifying patients with reflux disease (P < .001). The PSPW index and the MNBI identified patients with erosive reflux disease with the highest level of sensitivity (100% and 91%, respectively), as well as the 118 pH-positive (99% and 86%) and 103 pH-negative (77% and 56%) cases of NERD. The PSPW index and the MNBI identified pH-negative NERD with the highest level of sensitivity; values were 82% and 52% for the 65 SAP-positive and/or SI-positive cases and 68% and 63% for the 38 SAP-negative and SI-negative cases. Diagnoses of NERD were confirmed by pH-only criteria, including those that were positive on the basis of the SAP or SI, for 165 of 221 cases (75%) and by impedance pH criteria for 216 of 221 cases (98%) (P = .001). The PSPW index and the MNBI increase the diagnostic yield of impedance pH monitoring of patients with reflux disease. Analysis of impedance pH data by calculating the PSPW index and the MNBI can increase the accuracy of diagnosis of patients with reflux disease, compared with pH-only data. Copyright © 2016 AGA Institute. Published by Elsevier Inc. All rights reserved.
Gastric Emptying Assessment in Frequency and Time Domain Using Bio-impedance: Preliminary Results
NASA Astrophysics Data System (ADS)
Huerta-Franco, R.; Vargas-Luna, M.; Hernández, E.; Córdova, T.; Sosa, M.; Gutiérrez, G.; Reyes, P.; Mendiola, C.
2006-09-01
The impedance assessment to measure gastric emptying and in general gastric activity has been reported since 1985. The physiological interpretation of these measurements, is still under research. This technique usually uses a single frequency, and the conductivity parameter. The frequency domain and the Fourier analysis of the time domain behavior of the gastric impedance in different gastric conditions (fasting state, and after food administration) has not been explored in detail. This work presents some insights of the potentiality of these alternative methodologies to measure gastric activity.
NASA Technical Reports Server (NTRS)
Adams, D. F.; Hartmann, U. G.; Lazarow, L. L.; Maloy, J. O.; Mohler, G. W.
1976-01-01
The design of the vector magnetometer selected for analysis is capable of exceeding the required accuracy of 5 gamma per vector field component. The principal elements that assure this performance level are very low power dissipation triaxial feedback coils surrounding ring core flux-gates and temperature control of the critical components of two-loop feedback electronics. An analysis of the calibration problem points to the need for improved test facilities.
Model Parameterization and P-wave AVA Direct Inversion for Young's Impedance
NASA Astrophysics Data System (ADS)
Zong, Zhaoyun; Yin, Xingyao
2017-05-01
AVA inversion is an important tool for elastic parameters estimation to guide the lithology prediction and "sweet spot" identification of hydrocarbon reservoirs. The product of the Young's modulus and density (named as Young's impedance in this study) is known as an effective lithology and brittleness indicator of unconventional hydrocarbon reservoirs. Density is difficult to predict from seismic data, which renders the estimation of the Young's impedance inaccurate in conventional approaches. In this study, a pragmatic seismic AVA inversion approach with only P-wave pre-stack seismic data is proposed to estimate the Young's impedance to avoid the uncertainty brought by density. First, based on the linearized P-wave approximate reflectivity equation in terms of P-wave and S-wave moduli, the P-wave approximate reflectivity equation in terms of the Young's impedance is derived according to the relationship between P-wave modulus, S-wave modulus, Young's modulus and Poisson ratio. This equation is further compared to the exact Zoeppritz equation and the linearized P-wave approximate reflectivity equation in terms of P- and S-wave velocities and density, which illustrates that this equation is accurate enough to be used for AVA inversion when the incident angle is within the critical angle. Parameter sensitivity analysis illustrates that the high correlation between the Young's impedance and density render the estimation of the Young's impedance difficult. Therefore, a de-correlation scheme is used in the pragmatic AVA inversion with Bayesian inference to estimate Young's impedance only with pre-stack P-wave seismic data. Synthetic examples demonstrate that the proposed approach is able to predict the Young's impedance stably even with moderate noise and the field data examples verify the effectiveness of the proposed approach in Young's impedance estimation and "sweet spots" evaluation.
Dieng, Hamady; Satho, Tomomitsu; Suradi, Nur Farrahana Binti; Hakim, Hafijah; Abang, Fatimah; Aliasan, Nur Ezzati; Miake, Fumio; Zuharah, Wan Fatma; Kassim, Nur Faeza A; Majid, Abdul Hafiz A; Fadzly, Nik; Vargas, Ronald E Morales; Morales, Noppawan P; Noweg, Gabriel Tonga
2017-12-01
In dengue vector control, attempts to minimize or replace the use of pesticides have mostly involved use of predators, but success has been severely impeded by difficulties associated with financial and environmental costs, predator mass production, and persistence in target habitats. Visual deterrents have been used successfully to control animal pests, in some cases in an effort to replace pesticide use. Despite evidence that visual signals are crucial in site choice for egg deposition by dengue vectors, and that female mosquitoes respond to artificial predation, the role of predator intimidation as it affects the oviposition behavior of dengue vectors remains largely unexplored. Here, we examined the oviposition responses of Aedes aegypti exposed to various mosquito predator pictures. Gravid females were presented with equal opportunities to oviposit in two cups with predator images [Toxorhynchites splendens-TXI, Goldfish (Carassius auratus)-small (SFI) and large (LFI) and Tx. splendens+Goldfish-TXFI] and two others without pictures. Differences in egg deposition were examined between sites with and without these images. When given a chance to oviposit in cups with and without TXI, Ae. aegypti females were similarly attracted to both sites. When provided an opportunity to oviposit in cups displaying pictures of fish (SFI or LFI) and blank cups, egg deposition rates were much lower in the fish picture sites. Females showed a preference for blank cups over TXFI for egg deposition. They also equally avoided cups with pictures of fish, regardless of the size of the picture. Our results indicate that the presence of images of goldfish and their association with Tx. larvae significantly reduced egg deposition by Ae. aegypti, and this was not the case with the predatory larvae alone. The observations that the images of natural predators can repel gravid females of a dengue vector provide novel possibilities to develop effective and inexpensive alternative tools to harmful insecticides. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Filho, J. M. S.; Rodrigues Junior, C. A.; Sousa, D. G.; Oliveira, R. G. M.; Costa, M. M.; Barroso, G. C.; Sombra, A. S. B.
2017-07-01
The complex impedance spectroscopy study of magnesium niobate Mg4Nb2O9 (MN) ceramics with different additions of V2O5 (0%, 2%, 5%) was performed in this present paper. The preparation of MN samples were carried out by using the solid-state reaction method with a high-energy milling machine. Frequency and temperature dependence of the complex impedance, complex modulus analysis, and conductivity were measured and calculated at different temperatures by using a network impedance analyzer. A non-Debye type relaxation was observed showing a decentralization of the semicircles. Cole-Cole formalism was adopted here with the help of a computer program used to fit the experimental data. A typical universal dielectric response in the frequency-dependent conductivity at different temperatures was found. The frequency dependent ac conductivity at different temperatures indicates that the conduction process is thermally activated. The activation energy was obtained from the Arrhenius fitting by using conductivity and electrical modules data. The results would help to understand deeply the relaxation process in these types of materials.
Rae, L S; Vankan, D M; Rand, J S; Flickinger, E A; Ward, L C
2016-06-01
Thirty-five healthy, neutered, mixed breed dogs were used to determine the ability of multifrequency bioelectrical impedance analysis (MFBIA) to predict accurately fat-free mass (FFM) in dogs using dual energy X-ray absorptiometry (DXA)-measured FFM as reference. A second aim was to compare MFBIA predictions with morphometric predictions. MFBIA-based predictors provided an accurate measure of FFM, within 1.5% when compared to DXA-derived FFM, in normal weight dogs. FFM estimates were most highly correlated with DXA-measured FFM when the prediction equation included resistance quotient, bodyweight, and body condition score. At the population level, the inclusion of impedance as a predictor variable did not add substantially to the predictive power achieved with morphometric variables alone; in individual dogs, impedance predictors were more valuable than morphometric predictors. These results indicate that, following further validation, MFBIA could provide a useful tool in clinical practice to objectively measure FFM in canine patients and help improve compliance with prevention and treatment programs for obesity in dogs. Copyright © 2016. Published by Elsevier Ltd.
Development of Bio-impedance Analyzer (BIA) for Body Fat Calculation
NASA Astrophysics Data System (ADS)
Riyadi, Munawar A.; Nugraha, A.; Santoso, M. B.; Septaditya, D.; Prakoso, T.
2017-04-01
Common weight scales cannot assess body composition or determine fat mass and fat-fress mass that make up the body weight. This research propose bio-impedance analysis (BIA) tool capable to body composition assessment. This tool uses four electrodes, two of which are used for 50 kHz sine wave current flow to the body and the rest are used to measure the voltage produced by the body for impedance analysis. Parameters such as height, weight, age, and gender are provided individually. These parameters together with impedance measurements are then in the process to produce a body fat percentage. The experimental result shows impressive repeatability for successive measurements (stdev ≤ 0.25% fat mass). Moreover, result on the hand to hand node scheme reveals average absolute difference of total subjects between two analyzer tools of 0.48% (fat mass) with maximum absolute discrepancy of 1.22% (fat mass). On the other hand, the relative error normalized to Omron’s HBF-306 as comparison tool reveals less than 2% relative error. As a result, the system performance offers good evaluation tool for fat mass in the body.
Lutchen, K R
1990-08-01
A sensitivity analysis based on weighted least-squares regression is presented to evaluate alternative methods for fitting lumped-parameter models to respiratory impedance data. The goal is to maintain parameter accuracy simultaneously with practical experiment design. The analysis focuses on predicting parameter uncertainties using a linearized approximation for joint confidence regions. Applications are with four-element parallel and viscoelastic models for 0.125- to 4-Hz data and a six-element model with separate tissue and airway properties for input and transfer impedance data from 2-64 Hz. The criterion function form was evaluated by comparing parameter uncertainties when data are fit as magnitude and phase, dynamic resistance and compliance, or real and imaginary parts of input impedance. The proper choice of weighting can make all three criterion variables comparable. For the six-element model, parameter uncertainties were predicted when both input impedance and transfer impedance are acquired and fit simultaneously. A fit to both data sets from 4 to 64 Hz could reduce parameter estimate uncertainties considerably from those achievable by fitting either alone. For the four-element models, use of an independent, but noisy, measure of static compliance was assessed as a constraint on model parameters. This may allow acceptable parameter uncertainties for a minimum frequency of 0.275-0.375 Hz rather than 0.125 Hz. This reduces data acquisition requirements from a 16- to a 5.33- to 8-s breath holding period. These results are approximations, and the impact of using the linearized approximation for the confidence regions is discussed.
Omari, Taher I; Dejaeger, Eddy; Tack, Jan; Van Beckevoort, Dirk; Rommel, Nathalie
2013-06-01
Automated impedance manometry (AIM) analysis measures swallow variables defining bolus timing, pressure, contractile vigour, and bolus presence, which are combined to derive a swallow risk index (SRI) correlating with aspiration. In a heterogeneous cohort of dysphagia patients, we assessed the impact of bolus volume and viscosity on AIM variables. We studied 40 patients (average age = 46 years). Swallowing of boluses was recorded with manometry, impedance, and videofluoroscopy. AIMplot software was used to derive functional variables: peak pressure (PeakP), pressure at nadir impedance (PNadImp), time from nadir impedance to peak pressure (TNadImp-PeakP), the interval of impedance drop in the distal pharynx (flow interval, FI), upper oesophageal sphincter (UES) relaxation interval (UES RI), nadir UES pressure (Nad UESP), UES intrabolus pressure (UES IBP), and UES resistance. The SRI was derived using the formula SRI = (FI * PNadImp)/(PeakP * (TNadImp-PeakP + 1)) * 100. A total of 173 liquid, 44 semisolid, and 33 solid boluses were analysed. The SRI was elevated in relation to aspiration. PeakP increased with volume. SRI was not significantly altered by bolus volume. PNadImp, UES IBP, and UES resistance increased with viscosity. SRI was lower with increased viscosity. In patients with dysphagia, the SRI is elevated in relation to aspiration, reduced by bolus viscosity, and not affected by bolus volume. These data provide evidence that pharyngeal AIM analysis may have clinical utility for assessing deglutitive aspiration risk to liquid boluses.
Berg, E P; Neary, M K; Forrest, J C; Thomas, D L; Kauffman, R G
1996-11-01
Market weight lambs, average weight 52.5 kg (+/-6.1), were used to evaluate nontraditional live animal measurements as predictors of carcass composition. The sample population (n = 106) represented U.S. market lambs and transcended geographic location, breed, carcass weight, yield grade, and production system. Realtime ultrasonic (RU) measurements and bioelectrical impedance analysis (BIA) were used for development and evaluation of prediction equations for % boneless, closely trimmed primal cuts (BCTPC), weight or % of dissected lean tissue (TDL), and chemically derived weight or % fat-free lean (FFL). Longitudinal ultrasonic images were obtained parallel to the longissimus thoracis et lumborum (LTL), positioning the last costae in the center of the transducer head. Images were saved and fat and LTL depths were derived from printed images of the ultrasonic scans. Bioelectrical impedance analysis was administered via a four-terminal impedance plethysmograph operating at 800 microA at 50 kHz. Impedance measurements of whole-body resistance and reactance were recorded. Prediction equations including common linear measurements of live weight, heart girth, hindsaddle length, and shoulder height were also evaluated. All measurements were taken just before slaughter. Bioelectrical impedance measurements (as compared to RU and linear measurements) provided equations for %BCTPC, TDL, %TDL, FFL and %FFL with the highest R2 and lowest root mean square error. Even though BIA provided the best equations of the three methodologies tested, prediction of proportional yield (%BCTPC, %TDL, and %FFL) was marginal (R2 = .296, .551, and .551, respectively). Equations combining BIA, RU, and linear measurements greatly improved equations for prediction of proportional lean yield.
Analysis of asymmetric property with DC bias current on thin-film magnetoimpedance element
NASA Astrophysics Data System (ADS)
Kikuchi, Hiroaki; Sumida, Chihiro
2018-05-01
We theoretically analyzed the magnetoimpedance profile of a thin-film element with a DC bias current using the bias susceptibility theory and Maxwell's equations. Although the analysis model predicts that an element with a rectangular cross section shows symmetric impedance property with respect to the Z-axis with DC bias current, the experimental results showed asymmetric properties. Taking the shape imbalance and trapezoidal cross section of the element into account, we explained the asymmetric impedance properties qualitatively.
A new parallel-vector finite element analysis software on distributed-memory computers
NASA Technical Reports Server (NTRS)
Qin, Jiangning; Nguyen, Duc T.
1993-01-01
A new parallel-vector finite element analysis software package MPFEA (Massively Parallel-vector Finite Element Analysis) is developed for large-scale structural analysis on massively parallel computers with distributed-memory. MPFEA is designed for parallel generation and assembly of the global finite element stiffness matrices as well as parallel solution of the simultaneous linear equations, since these are often the major time-consuming parts of a finite element analysis. Block-skyline storage scheme along with vector-unrolling techniques are used to enhance the vector performance. Communications among processors are carried out concurrently with arithmetic operations to reduce the total execution time. Numerical results on the Intel iPSC/860 computers (such as the Intel Gamma with 128 processors and the Intel Touchstone Delta with 512 processors) are presented, including an aircraft structure and some very large truss structures, to demonstrate the efficiency and accuracy of MPFEA.
Impedance spectroscopy and electric modulus behavior of Molybdenum doped Cobalt-Zinc ferrite
NASA Astrophysics Data System (ADS)
Pradhan, A. K.; Nath, T. K.; Saha, S.
2017-07-01
The complex impedance spectroscopy and the electric modulus of Mo doped Cobalt-Zinc inverse spinel ferrite has been investigated in detail. The conventional ceramic technique has been used to prepare the CZMO. The HRXRD technique has been used to study the structural analysis which confirms the inverse spinel structure of the material and also suggest the material have Fd3m space group. The complex impedance spectroscopic data and the electric modulus formalism have been used to understand the dielectric relaxation and conduction process. The contribution of grain and grain boundary in the electrical conduction process of CZMO has been confirmed from the Cole-Cole plot. The activation energy is calculated from both the IS (Impedance Spectroscopy) and electric modulus formalism and found to be nearly same for the materials.
New power sharing control for inverter-dominated microgrid based on impedance match concept.
Gu, Herong; Wang, Deyu; Shen, Hong; Zhao, Wei; Guo, Xiaoqiang
2013-01-01
Power flow control is one of the most important issues for operating the inverter-dominated autonomous microgrid. A technical challenge is how to achieve the accurate active/reactive power sharing of inverters. P-F and Q-V droop control schemes have been widely used for power sharing in the past decades. But they suffer from the poor power sharing in the presence of unequal line impedance. In order to solve the problem, a comprehensive analysis of the power droop control is presented, and a new droop control based on the impedance match concept is proposed in this paper. In addition, the design guidelines of control coefficients and virtual impedance are provided. Finally, the performance evaluation is carried out, and the evaluation results verify the effectiveness of the proposed method.
Toxicity of graphene nanoflakes evaluated by cell-based electrochemical impedance biosensing.
Yoon, Ok Ja; Kim, Insu; Sohn, Il Yung; Kieu, Truong Thuy; Lee, Nae-Eung
2014-07-01
Graphene nanoflake toxicity was analyzed using cell-based electrochemical impedance biosensing with interdigitated indium tin oxide (ITO) electrodes installed in a custom-built mini-incubator positioned on an inverted optical microscope. Sensing with electrochemical measurements from interdigitated ITO electrodes was highly linear (R(2) = 0.93 and 0.96 for anodic peak current (Ipa) and cathodic peak current (Ipc), respectively). Size-dependent analysis of Graphene nanoflake toxicity was carried out in a mini-incubator system with cultured HeLa cells treated with Graphene nanoflakes having an average size of 80 or 30 nm for one day. Biological assays of cell proliferation and viability complemented electrochemical impedance measurements. The increased toxicity of smaller Graphene nanoflakes (30 nm) as measured by electrochemical impedance sensing and optical monitoring of treated cells was consistent with the biological assay results. Cell-based electrochemical impedance biosensing can be used to assess the toxicity of nanomaterials with different biomedical and environmental applications. © 2013 Wiley Periodicals, Inc.
On the use of The Bio-Impedance technique for Body Composition Measurements
NASA Astrophysics Data System (ADS)
Huerta-Franco, R.; Vargas-Luna, M.; González-Solís, J. L.; Gutiérrez-Juárez, G.
2003-09-01
Reviewing the methods and physical principles used in body composition measurements (BCM), it is evident that more accurate, reliable, and easily handled methods are required. The use of bio-impedance analysis (BIA) has been very useful in BCM. This technique, in the single frequency mode, has some commercial versions to perform BCM. However these apparatus have significant variability in the BCM values. The multi-frequency option of the bio-impedance technique has still a lot of challenges to overcome. We studied the variability of the body impedance spectrum (from 1 Hz to 1 MHz) in a group of subjects compared to the values obtained from commercial apparatus. We compared different anatomical body regions, some of them with less subcutaneous body fat (frontal, anterior tibial, knee, and frontal regions); others with more subcutaneous body fat (pectoral, abdominal, and internal calf regions). In order to model the bio-impedance spectrum, we analyzed layered samples with different thickness and material composition.
Vectorized Monte Carlo methods for reactor lattice analysis
NASA Technical Reports Server (NTRS)
Brown, F. B.
1984-01-01
Some of the new computational methods and equivalent mathematical representations of physics models used in the MCV code, a vectorized continuous-enery Monte Carlo code for use on the CYBER-205 computer are discussed. While the principal application of MCV is the neutronics analysis of repeating reactor lattices, the new methods used in MCV should be generally useful for vectorizing Monte Carlo for other applications. For background, a brief overview of the vector processing features of the CYBER-205 is included, followed by a discussion of the fundamentals of Monte Carlo vectorization. The physics models used in the MCV vectorized Monte Carlo code are then summarized. The new methods used in scattering analysis are presented along with details of several key, highly specialized computational routines. Finally, speedups relative to CDC-7600 scalar Monte Carlo are discussed.
Investigation of piezoelectric impedance-based health monitoring of structure interface debonding
NASA Astrophysics Data System (ADS)
Xiao, Li; Chen, Guofeng; Chen, Xiaoming; Qu, Wenzhong
2016-04-01
Various damages might occur during the solid rocket motor (SRM) manufacturing/operational phase, and the debonding of propellant/insulator/composite case interfaces is one of damage types which determine the life of a motor. The detection of such interface debonding damage will be beneficial for developing techniques for reliable nondestructive evaluation (NDE) and structural health monitoring (SHM). Piezoelectric sensors are widely used for structural health monitoring technique. In particular, electromechanical impedance (EMI) techniques give simple and low-cost solutions for detecting damage in various structures. In this work, piezoelectric EMI structural health monitoring technique is applied to identify the debonding condition of propellant/insulator interface structure using finite element method and experimental investigation. A three-dimensional coupled field finite element model is developed using the software ANSYS and the harmonic analysis is conducted for high-frequency impedance analysis procedure. In the experimental study, the impedance signals were measured from PZT and MFC sensors outside attached to composite case monitoring the different debonding conditions between the propellant and insulator. Root mean square deviation (RMSD) based damage index is conducted to quantify the changes i n impedance for different de bonding conditions and frequency range. Simulation and experimental results confirmed that the EMI technique can be used effectively for detecting the debonding damage in SRM and is expected to be useful for future application of real SRM's SHM.
[Activities of the Department of Electrical Engineering, Howard University
NASA Technical Reports Server (NTRS)
Yalamanchili, Raj C.
1997-01-01
Theoretical derivations, computer analysis and test data are provided to demonstrate that the cavity model is a feasible one to analyze thin-substrate, rectangular-patch microstrip antennas. Seven separate antennas were tested. Most of the antennas were designed to resonate at L-band frequencies (1-2 GHz). One antenna was designed to resonate at an S-band (2-4 GHz) frequency of 2.025 GHz. All dielectric substrates were made of Duroid, and were of varying thicknesses and relative dielectric constant values. Theoretical derivations to calculate radiated free space electromagnetic fields and antenna input impedance were performed. MATHEMATICA 2.2 software was used to generate Smith Chart input impedance plots, normalized relative power radiation plots and to perform other numerical manipulations. Network Analyzer tests were used to verify the data from the computer programming (such as input impedance and VSWR). Finally, tests were performed in an anechoic chamber to measure receive-mode polar power patterns in the E and H planes. Agreement between computer analysis and test data is presented. The antenna with the thickest substrate (e(sub r) = 2.33,62 mils thick) showed the worst match to theoretical impedance data. This is anticipated due to the fact that the cavity model generally loses accuracy when the dielectric substrate thickness exceeds 5% of the antenna's free space wavelength. A method of reducing computer execution time for impedance calculations is also presented.
Correlation between polar values and vector analysis.
Naeser, K; Behrens, J K
1997-01-01
To evaluate the possible correlation between polar value and vector analysis assessment of surgically induced astigmatism. Department of Ophthalmology, Aalborg Sygehus Syd, Denmark. The correlation between polar values and vector analysis was evaluated by simple mathematical and optical methods using accepted principles of trigonometry and first-order optics. Vector analysis and polar values report different aspects of surgically induced astigmatism. Vector analysis describes the total astigmatic change, characterized by both astigmatic magnitude and direction, while the polar value method produces a single, reduced figure that reports flattening or steepening in preselected directions, usually the plane of the surgical meridian. There is a simple Pythagorean correlation between vector analysis and two polar values separated by an arch of 45 degrees. The polar value calculated in the surgical meridian indicates the power or the efficacy of the surgical procedure. The polar value calculated in a plane inclined 45 degrees to the surgical meridian indicates the degree of cylinder rotation induced by surgery. These two polar values can be used to obtain other relevant data such as magnitude, direction, and sphere of an induced cylinder. Consistent use of these methods will enable surgeons to control and in many cases reduce preoperative astigmatism.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chin, Yong Ho; Chao, Alexander Wu; Blaskiewicz, Michael M.
Effects of the chromaticity on head-tail instabilities for broadband impedances are comprehensively studied, using the two particle model, the Vlasov analysis and computer simulations. We show both in the two particle model and the Vlasov analysis with the trapezoidal (semiconstant) wake model that we can derive universal contour plots for the growth factor as a function of the two dimensionless parameters: the wakefield strength, Υ, and the difference of the betatron phase advances between the head and the tail, χ. They reveal how the chromaticity affects strong head-tail instabilities and excites head-tail instabilities. We also apply the LEP (Large Electron-Positronmore » Collider) broadband resonator model to the Vlasov approach and find that the results are in very good agreement with those of the trapezoidal wake model. The theoretical findings are also reinforced by the simulation results. In conclusion, the trapezoidal wake model turns out to be a very useful tool since it significantly simplifies the time domain analysis and provides well-behaved impedance at the same time.« less
Chin, Yong Ho; Chao, Alexander Wu; Blaskiewicz, Michael M.; ...
2017-07-28
Effects of the chromaticity on head-tail instabilities for broadband impedances are comprehensively studied, using the two particle model, the Vlasov analysis and computer simulations. We show both in the two particle model and the Vlasov analysis with the trapezoidal (semiconstant) wake model that we can derive universal contour plots for the growth factor as a function of the two dimensionless parameters: the wakefield strength, Υ, and the difference of the betatron phase advances between the head and the tail, χ. They reveal how the chromaticity affects strong head-tail instabilities and excites head-tail instabilities. We also apply the LEP (Large Electron-Positronmore » Collider) broadband resonator model to the Vlasov approach and find that the results are in very good agreement with those of the trapezoidal wake model. The theoretical findings are also reinforced by the simulation results. In conclusion, the trapezoidal wake model turns out to be a very useful tool since it significantly simplifies the time domain analysis and provides well-behaved impedance at the same time.« less
Qualitative human body composition analysis assessed with bioelectrical impedance.
Talluri, T
1998-12-01
Body composition is generally aiming at quantitative estimates of fat mass, inadequate to assess nutritional states that on the other hand are well defined by the intra/extra cellular masses proportion (ECM/BCM). Direct measures performed with phase sensitive bioelectrical impedance analyzers can be used to define the current distribution in normal and abnormal populations. Phase angle and reactance nomogram is directly reflecting the ECM/BCM pathways proportions and body impedance analysis (BIA) is also validated to estimate the individual content of body cell mass (BCM). A new body cell mass index (BCMI) obtained dividing the weight of BCM in kilograms by the body surface in square meters is confronted to the scatterplot distribution of phase angle and reactance values obtained from controls and patients, and proposed as a qualitative approach to identify abnormal ECM/BCM ratios and nutritional states.
NASA Astrophysics Data System (ADS)
Omar, N. M.; Ahmad, A. Hanom
2009-06-01
The coating resistance of the Dammar-based paint system was determined by using Electrochemical Impedance Spectroscopy (EIS), whereas, the corrosion potential analysis was determined by using potential time measurement (PTM) method. Carotenoid pigment obtained from Capsicum Annum (dried chili pepper) was added into the mixture of dammar and acrylic polyol resin and the paint systems were proofed on Aluminium steel Q-panels as a substrate. Result shows that the paint system with a composition of 35% dammar (CD35%) possessed the higher corrosion resistance after 30 days of exposure in 3% NaCl solution for electrochemical impedance spectroscopy and also can withstand the longest time for delimitation protection in PTM analysis. The results prove that the developed organic paint system can improve the electrochemical and corrosion protection properties of a paint system.
Dielectric and impedance studies of Ba0.50(Na0.25Bi0.25)(Fe0.25Nb0.25)Ti0.50O3 ceramic
NASA Astrophysics Data System (ADS)
Yadav, Anjana; Chandra, K. P.; Kulkarni, A. R.; Prasad, K.
2018-05-01
Lead-free perovskite Ba0.50(Na0.25Bi0.25)(Fe0.25Nb0.25)Ti0.50O3 was prepared using conventional ceramic technique at 1130°C/4h in air atmosphere and characterized by X-ray diffraction, scanning electron microscopy, dielectric and impedance studies. XRD analysis of the compound indicated the formation of a single-phase cubic structure. SEM study was carried out to study the quality and purity of the compound. Compound showed very high dielectric constant (33700). Impedance analysis indicated the negative temperature coefficient of resistance character of the compound. Ac conductivity data followed Jonscher's law and correlated barrier hopping successfully explained the charge carrier transport mechanism in the system.
Analysis of the electromagnetic scattering from an inlet geometry with lossy walls
NASA Technical Reports Server (NTRS)
Myung, N. H.; Pathak, P. H.; Chunang, C. D.
1985-01-01
One of the primary goals is to develop an approximate but sufficiently accurate analysis for the problem of electromagnetic (EM) plane wave scattering by an open ended, perfectly-conducting, semi-infinite hollow circular waveguide (or duct) with a thin, uniform layer of lossy or absorbing material on its inner wall, and with a simple termination inside. The less difficult but useful problem of the EM scattering by a two-dimensional (2-D), semi-infinite parallel plate waveguide with an impedance boundary condition on the inner walls was chosen initially for analysis. The impedance boundary condition in this problem serves to model a thin layer of lossy dielectric/ferrite coating on the otherwise perfectly-conducting interior waveguide walls. An approximate but efficient and accurate ray solution was obtained recently. That solution is presently being extended to the case of a moderately thick dielectric/ferrite coating on the walls so as to be valid for situations where the impedance boundary condition may not remain sufficiently accurate.
Urdapilleta, E; Bellotti, M; Bonetto, F J
2006-10-01
In this paper we present a model to describe the electrical properties of a confluent cell monolayer cultured on gold microelectrodes to be used with electric cell-substrate impedance sensing technique. This model was developed from microscopic considerations (distributed effects), and by assuming that the monolayer is an element with mean electrical characteristics (specific lumped parameters). No assumptions were made about cell morphology. The model has only three adjustable parameters. This model and other models currently used for data analysis are compared with data we obtained from electrical measurements of confluent monolayers of Madin-Darby Canine Kidney cells. One important parameter is the cell-substrate height and we found that estimates of this magnitude strongly differ depending on the model used for the analysis. We analyze the origin of the discrepancies, concluding that the estimates from the different models can be considered as limits for the true value of the cell-substrate height.
Sakin, Yusuf S; Vardar, Rukiye; Sezgin, Baha; Cetin, Zeynep Erdogan; Alev, Yasemin; Yildirim, Esra; Kirazli, Tayfun; Bor, Serhat
2017-08-01
The diagnosis of laryngopharyngeal reflux is currently based on a combination of the patient history of multichannel intraluminal impedance and ambulatory pH (MII-pH); however, none of these findings alone is specific for the diagnosis of laryngopharyngeal reflux. We aimed to compare the baseline characteristics and esophageal baseline impedance values between patients with and without laryngopharyngeal reflux symptoms. We retrospectively analyzed data from two groups of patients with laryngopharyngeal reflux according to their reflux finding score (RFS) as scored by ENTs. Control patients were nonerosive reflux disease patients without laryngopharyngeal reflux. All MII-pH parameters and baseline impedance were analyzed from six levels and the proximal and distal baseline impedance and the ratio of the proximal to distal baseline impedance levels was calculated. Altogether 123 patients with laryngopharyngeal reflux and 49 control patients were included. A total of 81 of 123 patients had RFS ≥ 7, and 42 of 123 patients had RFS < 7. Baseline impedance analysis showed that patients with laryngopharyngeal reflux symptoms had significantly lower proximal baseline impedance values (1997 ± 51 vs 2245 ± 109, p < 0.05) than the control group. Additionally, patients with laryngopharyngeal reflux symptoms had a significantly lower proximal-to-distal ratio (1.28 ± 0.05 vs 1.53 ± 0.09, p < 0.05). In the subgroup analysis, patients with RFS < 7 were found to have a significantly lower acid exposure time than either the patients with RFS ≥ 7 (3.85 ± 0.65 vs 8.2 ± 1.52, p < 0.05) or the control group (3.85 ± 0.65 vs 6.1 ± 0.81, p < 0.05). Additionally, patients with RFS ≥ 7 had significantly lower proximal baseline impedance levels than the control group (1970 ± 63 vs 2245 ± 109, p < 0.05). Patients with pathologic laryngopharyngeal reflux symptom scores had lower proximal baseline impedance levels and lower proximal-to-distal ratios, which may reflect the proximal mucosal noxious effect of the refluxate. These results may indicate that laryngopharyngeal reflux symptoms may be due to chronic acid exposure in the proximal segments of the esophagus, and the proximal-to-distal ratio may be used as a new metric for diagnosis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Yanlin; Wang, Mi; Yao, Jun
2014-04-11
Electrical impedance tomography (EIT) is one of the process tomography techniques to provide an on-line non-invasive imaging for multiphase flow measurement. With EIT measurements, the images of impedance real part, impedance imaginary part, phase angle, and magnitude can be obtained. However, most of the applications of EIT in the process industries rely on the conductivity difference between two phases in fluids to obtain the concentration profiles. It is not common to use the imaginary part or phase angle due to the dominant change in conductivity or complication in the use of other impedance information. In a solid-liquid two phases systemmore » involving nano- or submicro-particles, characterisation of particles (e.g. particle size and concentration) have to rely on the measurement of impedance phase angle or imaginary part. Particles in a solution usually have an electrical double layer associated with their surfaces and can form an induced electrical dipole moment due to the polarization of the electrical double layer under the influence of an alternating electric field. Similar to EIT, electrical impedance spectroscopy (EIS) measurement can record the electrical impedance data, including impedance real part, imaginary part and phase angle (θ), which are caused by the polarization of the electrical double layer. These impedance data are related to the particle characteristics e.g. particle size, particle and ionic concentrations in the aqueous medium, therefore EIS method provides a capability for characterising the particles in suspensions. Electrical impedance tomography based on EIS measurement or namely, electrical impedance tomography spectroscopy (EITS) could image the spatial distribution of particle characteristics. In this paper, a new method, including test set-up and data analysis, for characterisation of particles in suspensions are developed through the experimental approach. The experimental results on tomographic imaging of colloidal particles based on EIS measurement using a sensor of 8 electrodes are reported. Results have demonstrated the potential as well as revealed the challenge in the use of EIS and EITS for characterisation of particle in suspension.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirby, R. Jason
2016-08-15
Cardiac safety assays incorporating label-free detection of human stem-cell derived cardiomyocyte contractility provide human relevance and medium throughput screening to assess compound-induced cardiotoxicity. In an effort to provide quantitative analysis of the large kinetic datasets resulting from these real-time studies, we applied bioinformatic approaches based on nonlinear dynamical system analysis, including limit cycle analysis and autocorrelation function, to systematically assess beat irregularity. The algorithms were integrated into a software program to seamlessly generate results for 96-well impedance-based data. Our approach was validated by analyzing dose- and time-dependent changes in beat patterns induced by known proarrhythmic compounds and screening a cardiotoxicitymore » library to rank order compounds based on their proarrhythmic potential. We demonstrate a strong correlation for dose-dependent beat irregularity monitored by electrical impedance and quantified by autocorrelation analysis to traditional manual patch clamp potency values for hERG blockers. In addition, our platform identifies non-hERG blockers known to cause clinical arrhythmia. Our method provides a novel suite of medium-throughput quantitative tools for assessing compound effects on cardiac contractility and predicting compounds with potential proarrhythmia and may be applied to in vitro paradigms for pre-clinical cardiac safety evaluation. - Highlights: • Impedance-based monitoring of human iPSC-derived cardiomyocyte contractility • Limit cycle analysis of impedance data identifies aberrant oscillation patterns. • Nonlinear autocorrelation function quantifies beat irregularity. • Identification of hERG and non-hERG inhibitors with known risk of arrhythmia • Automated software processes limit cycle and autocorrelation analyses of 96w data.« less
Andrade, N J; Bridgeman, T A; Zottola, E A
1998-07-01
Enterococcus faecium attached to stainless steel chips (100 mm2) was treated with the following sanitizers: sodium hypochlorite, peracetic acid (PA), peracetic acid plus an organic acid (PAS), quaternary ammonium, organic acid, and anionic acid. The effectiveness of sanitizer solutions on planktonic cells (not attached) was evaluated by the Association of Official Analytical Chemists (AOAC) suspension test. The number of attached cells was determined by impedance measurement and plate count method after vortexing. The decimal reduction (DR) in numbers of the E. faecium population was determined for the three methods and was analyzed by analysis of variance (P < 0.05) using Statview software. The adhered cells were more resistant (P < 0.05) than nonadherent cells. The DR averages for all of the sanitizers for 30 s of exposure were 6.4, 2.2, and 2.5 for the AOAC suspension test, plate count method after vortexing, and impedance measurement, respectively. Plate count and impedance methods showed a difference (P < 0.05) after 30 s of sanitizer exposure but not after 2 min. The impedance measurement was the best method to measure adherent cells. Impedance measurement required the development of a quadratic regression. The equation developed from 82 samples is as follows: log CFU/chip = 0.2385T2-0.96T + 9.35, r2 = 0.92, P < 0.05, T = impedance detection time in hours. This method showed that the sanitizers PAS and PA were more effective against E. faecium than the other sanitizers. At 30 s, the impedance method recovered about 25 times more cells than the plate count method after vortexing. These data suggest that impedance measurement is the method of choice when evaluating the number of bacterial cells adhered to a surface.
Visceral fat estimation method by bioelectrical impedance analysis and causal analysis
NASA Astrophysics Data System (ADS)
Nakajima, Hiroshi; Tasaki, Hiroshi; Tsuchiya, Naoki; Hamaguchi, Takehiro; Shiga, Toshikazu
2011-06-01
It has been clarified that abdominal visceral fat accumulation is closely associated to the lifestyle disease and metabolic syndrome. The gold standard in medical fields is visceral fat area measured by an X-ray computer tomography (CT) scan or magnetic resonance imaging. However, their measurements are high invasive and high cost; especially a CT scan causes X-ray exposure. They are the reasons why medical fields need an instrument for viscera fat measurement with low invasive, ease of use, and low cost. The article proposes a simple and practical method of visceral fat estimation by employing bioelectrical impedance analysis and causal analysis. In the method, abdominal shape and dual impedances of abdominal surface and body total are measured to estimate a visceral fat area based on the cause-effect structure. The structure is designed according to the nature of abdominal body composition to be fine-tuned by statistical analysis. The experiments were conducted to investigate the proposed model. 180 subjects were hired to be measured by both a CT scan and the proposed method. The acquired model explained the measurement principle well and the correlation coefficient is 0.88 with the CT scan measurements.
Arii, Jun; Hushur, Orkash; Kato, Kentaro; Kawaguchi, Yasushi; Tohya, Yukinobu; Akashi, Hiroomi
2006-04-01
Canine herpesvirus (CHV) is an attractive candidate not only for use as a recombinant vaccine to protect dogs from a variety of canine pathogens but also as a viral vector for gene therapy in domestic animals. However, developments in this area have been impeded by the complicated techniques used for eukaryotic homologous recombination. To overcome these problems, we used bacterial artificial chromosomes (BACs) to generate infectious BACs. Our findings may be summarized as follows: (i) the CHV genome (pCHV/BAC), in which a BAC flanked by loxP sites was inserted into the thymidine kinase gene, was maintained in Escherichia coli; (ii) transfection of pCHV/BAC into A-72 cells resulted in the production of infectious virus; (iii) the BAC vector sequence was almost perfectly excisable from the genome of the reconstituted virus CHV/BAC by co-infection with CHV/BAC and a recombinant adenovirus that expressed the Cre recombinase; and (iv) a recombinant virus in which the glycoprotein C gene was deleted was generated by lambda recombination followed by Flp recombination, which resulted in a reduction in viral titer compared with that of the wild-type virus. The infectious clone pCHV/BAC is useful for the modification of the CHV genome using bacterial genetics, and CHV/BAC should have multiple applications in the rapid generation of genetically engineered CHV recombinants and the development of CHV vectors for vaccination and gene therapy in domestic animals.
Sharma, Nandita; Gedeon, Tom
2012-12-01
Stress is a major growing concern in our day and age adversely impacting both individuals and society. Stress research has a wide range of benefits from improving personal operations, learning, and increasing work productivity to benefiting society - making it an interesting and socially beneficial area of research. This survey reviews sensors that have been used to measure stress and investigates techniques for modelling stress. It discusses non-invasive and unobtrusive sensors for measuring computed stress, a term we coin in the paper. Sensors that do not impede everyday activities that could be used by those who would like to monitor stress levels on a regular basis (e.g. vehicle drivers, patients with illnesses linked to stress) is the focus of the discussion. Computational techniques have the capacity to determine optimal sensor fusion and automate data analysis for stress recognition and classification. Several computational techniques have been developed to model stress based on techniques such as Bayesian networks, artificial neural networks, and support vector machines, which this survey investigates. The survey concludes with a summary and provides possible directions for further computational stress research. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Wang, Lucy L; Ahad, Mohammad; McEwan, Alistair; Li, Jia; Jafarpoor, Mina; Rutkove, Seward B
2011-06-01
The surface measurement of electrical impedance of muscle, incorporated as the technique of electrical impedance myography (EIM), provides a noninvasive approach for evaluating neuromuscular diseases, including amyotrophic lateral sclerosis. However, the relationship between alterations in surface impedance and the electrical properties of muscle remains uncertain. In order to investigate this further, a group of healthy adult rats, a group of rats two weeks postsciatic crush, and a group of animals six months postcrush underwent EIM of the gastrocnemius-soleus complex. The animals were then killed and the conductivity and permittivity of the extracted muscle measured. Finite-element models based on MRI data were then constructed for each group. The characteristic EIM parameter, 50 kHz phase (±standard error), obtained with surface impedance measurements was 17.3° ± 0.3° for normal animals, 13.8° ± 0.7° for acutely injured animals, and 16.1° ± 0.5° for chronically injured animals. The models predicted parallel changes with phase values of 24.3°, 18.8°, and 21.2° for the normal, acute, and chronic groups, respectively. Other multifrequency impedance parameters showed similar alterations. These results confirm that surface impedance measurements taken in conjunction with anatomical data and finite-element models may offer a noninvasive approach for assessing biophysical alterations in muscle in neuromuscular disease states.
Two-port network analysis and modeling of a balanced armature receiver.
Kim, Noori; Allen, Jont B
2013-07-01
Models for acoustic transducers, such as loudspeakers, mastoid bone-drivers, hearing-aid receivers, etc., are critical elements in many acoustic applications. Acoustic transducers employ two-port models to convert between acoustic and electromagnetic signals. This study analyzes a widely-used commercial hearing-aid receiver ED series, manufactured by Knowles Electronics, Inc. Electromagnetic transducer modeling must consider two key elements: a semi-inductor and a gyrator. The semi-inductor accounts for electromagnetic eddy-currents, the 'skin effect' of a conductor (Vanderkooy, 1989), while the gyrator (McMillan, 1946; Tellegen, 1948) accounts for the anti-reciprocity characteristic [Lenz's law (Hunt, 1954, p. 113)]. Aside from Hunt (1954), no publications we know of have included the gyrator element in their electromagnetic transducer models. The most prevalent method of transducer modeling evokes the mobility method, an ideal transformer instead of a gyrator followed by the dual of the mechanical circuit (Beranek, 1954). The mobility approach greatly complicates the analysis. The present study proposes a novel, simplified and rigorous receiver model. Hunt's two-port parameters, the electrical impedance Ze(s), acoustic impedance Za(s) and electro-acoustic transduction coefficient Ta(s), are calculated using ABCD and impedance matrix methods (Van Valkenburg, 1964). The results from electrical input impedance measurements Zin(s), which vary with given acoustical loads, are used in the calculation (Weece and Allen, 2010). The hearing-aid receiver transducer model is designed based on energy transformation flow [electric→ mechanic→ acoustic]. The model has been verified with electrical input impedance, diaphragm velocity in vacuo, and output pressure measurements. This receiver model is suitable for designing most electromagnetic transducers and it can ultimately improve the design of hearing-aid devices by providing a simplified yet accurate, physically motivated analysis. This article is part of a special issue entitled "MEMRO 2012". Published by Elsevier B.V.
TRANSVERSE ELECTRIC IMPEDANCE OF THE SQUID GIANT AXON
Curtis, Howard J.; Cole, Kenneth S.
1938-01-01
The impedance of the excised giant axon from hindmost stellar nerve of Loligo pealii has been measured over the frequency range from 1 to 2500 kilocycles per second. The measurements have been made with the current flow perpendicular to the axis of the axon to permit a relatively simple analysis of the data. It has been found that the axon membrane has a polarization impedance with an average phase angle of 76° and an average capacity of 1.1µf./cm2 at 1 kilocycle. The direct current resistance of the membrane could not be measured, but was greater than 3 ohm cm.2 and the average internal specific resistance was four times that of sea water. There was no detectable change in the membrane impedance when the axon lost excitability, but some time later it decreased to zero. PMID:19873081
New Power Sharing Control for Inverter-Dominated Microgrid Based on Impedance Match Concept
Gu, Herong; Wang, Deyu; Shen, Hong; Zhao, Wei; Guo, Xiaoqiang
2013-01-01
Power flow control is one of the most important issues for operating the inverter-dominated autonomous microgrid. A technical challenge is how to achieve the accurate active/reactive power sharing of inverters. P-F and Q-V droop control schemes have been widely used for power sharing in the past decades. But they suffer from the poor power sharing in the presence of unequal line impedance. In order to solve the problem, a comprehensive analysis of the power droop control is presented, and a new droop control based on the impedance match concept is proposed in this paper. In addition, the design guidelines of control coefficients and virtual impedance are provided. Finally, the performance evaluation is carried out, and the evaluation results verify the effectiveness of the proposed method. PMID:24453910
NASA Technical Reports Server (NTRS)
Montogomery, Leslie D.; Ku, Yu-Tsuan E.; Webbon, Bruce W. (Technical Monitor)
1995-01-01
We have prepared a computer program (RHEOSYS:RHEOencephalographic impedance trace scanning SyStem) that can be used to automate the analysis of segmental impedance blood flow waveforms. This program was developed to assist in the post test analysis of recorded impedance traces from multiple segments of the body. It incorporates many of the blood flow, segmental volume, and vascular state indices reported in the world literature. As it is currently programmed, seven points are selected from each blood flow pulse and associated ECG waveforrn: 1. peak of the first ECG QRS complex, 2. start of systolic slope on the blood flow trace, 3. maximum amplitude of the impedance pulse, 4. position of the dicrotic notch, 5. maximum amplitude of the postdicrotic segment, 6. peak of the second ECG QRS complex, and 7. start of the next blood flow pulse. These points we used to calculate various geometric, area, and time-related values associated with the impedance pulse morphology. RHEOSYS then calculates a series of 34 impedance and cardiac cycle parameters which include pulse amplitudes; areas; pulse propagation times; cardiac cycle times; and various measures of arterial and various tone, contractility, and pulse volume. We used this program to calculate the scalp and intracranial blood flow responses to head and neck cooling as it may be applied to lower the body temperatures of multiple sclerosis patients. Twelve women and twelve men were tested using a commercially available head and neck cooling system operated at its maximum cooling capacity for a period of 30 minutes. Head and neck cooling produced a transient change in scalp blood flow and a significant, (P<0.05) decrease of approx. 30% in intracranial blood flow. Results of this experiment will illustrate how REG and RHEOSYS can be used in biomedical applications.
Gunawan, Agus Indra; Hozumi, Naohiro; Takahashi, Kenta; Yoshida, Sachiko; Saijo, Yoshifumi; Kobayashi, Kazuto; Yamamoto, Seiji
2015-12-01
A new technique is proposed for non-contact quantitative cell observation using focused ultrasonic waves. This technique interprets acoustic reflection intensity into the characteristic acoustic impedance of the biological cell. The cells are cultured on a plastic film substrate. A focused acoustic beam is transmitted through the substrate to its interface with the cell. A two-dimensional (2-D) reflection intensity profile is obtained by scanning the focal point along the interface. A reference substance is observed under the same conditions. These two reflections are compared and interpreted into the characteristic acoustic impedance of the cell based on a calibration curve that was created prior to the observation. To create the calibration curve, a numerical analysis of the sound field is performed using Fourier Transforms and is verified using several saline solutions. Because the cells are suspended by two plastic films, no contamination is introduced during the observation. In a practical observation, a sapphire lens transducer with a center frequency of 300 MHz was employed using ZnO thin film. The objects studied were co-cultured rat-derived glial (astrocyte) cells and glioma cells. The result was the clear observation of the internal structure of the cells. The acoustic impedance of the cells was spreading between 1.62 and 1.72 MNs/m(3). Cytoskeleton was indicated by high acoustic impedance. The introduction of cytochalasin-B led to a significant reduction in the acoustic impedance of the glioma cells; its effect on the glial cells was less significant. It is believed that this non-contact observation method will be useful for continuous cell inspections. Copyright © 2015 Elsevier B.V. All rights reserved.
Kriščiukaitis, Algimantas; Šimoliūnienė, Renata; Macas, Andrius; Petrolis, Robertas; Drėgūnas, Kęstutis; Bakšytė, Giedrė; Pieteris, Linas; Bertašienė, Zita; Žaliūnas, Remigijus
2014-01-01
Beat-to-beat alteration in ventricles repolarization reflected by alternans of amplitude and/or shape of ECG S-T,T segment (TWA) is known as phenomena related with risk of severe arrhythmias leading to sudden cardiac death. Technical difficulties have caused limited its usage in clinical diagnostics. Possibilities to register and analyze multimodal signals reflecting heart activity inspired search for new technical solutions. First objective of this study was to test whether thoracic impedance signal and beat-to-beat heart rate reflect repolarization alternans detected as TWA. The second objective was revelation of multimodal signal features more comprehensively representing the phenomena and increasing its prognostic usefulness. ECG, and thoracic impedance signal recordings made during 24h follow-up of the patients hospitalized in acute phase of myocardial infarction were used for investigation. Signal morphology variations reflecting estimates were obtained by the principal component analysis-based method. Clinical outcomes of patients (survival and/or rehospitalization in 6 and 12 months) were compared to repolarization alternans and heart rate variability estimates. Repolarization alternans detected as TWA was also reflected in estimates of thoracic impedance signal shape and variation in beat-to-beat heart rate. All these parameters showed correlation with clinical outcomes of patients. The strongest significant correlation showed magnitude of alternans in estimates of thoracic impedance signal shape. The features of ECG, thoracic impedance signal and beat-to-beat variability of heart rate, give comprehensive estimates of repolarization alternans, which correlate, with clinical outcomes of the patients and we recommend using them to improve diagnostic reliability. Copyright © 2014 Lithuanian University of Health Sciences. Production and hosting by Elsevier Urban & Partner Sp. z o.o. All rights reserved.
RTEMIS: Real-time Tumoroid and Environment Monitoring Using Impedance Spectroscopy and pH Sensing
NASA Astrophysics Data System (ADS)
Alexander, Frank A., Jr.
This research utilizes Electrical Impedance Spectroscopy, a technique classically used for electrochemical analysis and material characterization, as the basis for a non-destructive, label-free assay platform for three dimensional (3D) cellular spheroids. In this work, a linear array of microelectrodes is optimized to rapidly respond to changes located within a 3D multicellular model. In addition, this technique is coupled with an on chip micro-pH sensor for monitoring the environment around the cells. Finally, the responses of both impedance and pH are correlated with physical changes within the cellular model. The impedance analysis system realized through this work provides a foundation for the development of high-throughput drug screening systems that utilize multiple parallel sensing modalities including pH and impedance sensing in order to quickly assess the efficacy of specific drug candidates. The slow development of new drugs is mainly attributed to poor predictability of current chemosensitivity and resistivity assays, as well as genetic differences between the animal models used for tests and humans. In addition, monolayer cultures used in early experimentation are fundamentally different from the complex structure of organs in vivo. This requires the study of smaller 3D models (spheroids) that more efficiently replicate the conditions within the body. The main objective of this research was to develop a microfluidic system on a chip that is capable of deducing viability and morphology of 3D tumor spheroids by monitoring both the impedance of the cellular model and the pH of their local environment. This would provide a fast and reliable method for screening pharmaceutical compounds in a high-throughput system.
Guidi, Giada; Savarino, Edoardo V.; Frazzoni, Marzio; Tolone, Salvatore; Frazzoni, Leonardo; Fuccio, Lorenzo; Bertani, Lorenzo; Bodini, Giorgia; Ceccarelli, Linda; Marchi, Santino; de Bortoli, Nicola
2018-01-01
Background and Aims By means of 24 h impedance-pH monitoring, we aimed to evaluate the effect of two different meals with a bromatological balanced composition: one with a prevailing component of animal proteins and the other with vegetable proteins. Patients and Methods We enrolled 165 patients with heartburn and negative endoscopy, who underwent impedance-pH monitoring off therapy. Patients were allocated to receive a Mediterranean diet with a total caloric intake of about 1694 kcal, divided into two meals: one with a prevailing component of animal proteins and the other with vegetable proteins. We evaluated the total reflux number, acid exposure time (AET), and symptom-reflux association with impedance-pH analysis. Moreover, during the first postprandial hour (at lunch and dinner), we evaluated the total reflux number, number of acid and weakly acidic refluxes, AET, and presence of symptoms. Results The male/female ratio was 80/85. Mean age was 51.9 ± 12.1 years. Impedance-pH analysis showed that 55/165 patients had pathological AET or a number of refluxes (nonerosive reflux disease (NERD)), 49/165 had normal AET and a number of refluxes but positive symptom-reflux association (hypersensitive esophagus (HE)), and 61/165 had normal AET and a number of refluxes with negative symptom-reflux association (functional heartburn (FH)). The overall first postprandial hour analysis showed a higher total reflux number, acid reflux number, and AET after the animal protein meal than after the vegetable protein meal. Moreover, more symptoms were reported after the animal protein meal. Similar results have been observed in the three different subcategories of patients (NERD, HE, and FH). Conclusions Vegetable proteins are associated with a lower number of refluxes, particularly acid refluxes, and with a reduced number of symptoms during the first postprandial hour. This is a pilot study and future investigations are warranted to confirm these results. PMID:29849599
System-Level Biochip for Impedance Sensing and Programmable Manipulation of Bladder Cancer Cells
Chuang, Cheng-Hsin; Huang, Yao-Wei; Wu, Yao-Tung
2011-01-01
This paper develops a dielectrophoretic (DEP) chip with multi-layer electrodes and a micro-cavity array for programmable manipulations of cells and impedance measurement. The DEP chip consists of an ITO top electrode, flow chamber, middle electrode on an SU-8 surface, micro-cavity arrays of SU-8 and distributed electrodes at the bottom of the micro-cavity. Impedance sensing of single cells could be performed as follows: firstly, cells were trapped in a micro-cavity array by negative DEP force provided by top and middle electrodes; then, the impedance measurement for discrimination of different stage of bladder cancer cells was accomplished by the middle and bottom electrodes. After impedance sensing, the individual releasing of trapped cells was achieved by negative DEP force using the top and bottom electrodes in order to collect the identified cells once more. Both cell manipulations and impedance measurement had been integrated within a system controlled by a PC-based LabVIEW program. In the experiments, two different stages of bladder cancer cell lines (grade III: T24 and grade II: TSGH8301) were utilized for the demonstration of programmable manipulation and impedance sensing; as the results show, the lower-grade bladder cancer cells (TSGH8301) possess higher impedance than the higher-grade ones (T24). In general, the multi-step manipulations of cells can be easily programmed by controlling the electrical signal in our design, which provides an excellent platform technology for lab-on-a-chip (LOC) or a micro-total-analysis-system (Micro TAS). PMID:22346685
Conversion loss and noise of microwave and millimeter-wave mixers. I - Theory. II - Experiment
NASA Technical Reports Server (NTRS)
Held, D. N.; Kerr, A. R.
1978-01-01
The conversion loss and noise of microwave and millimeter-wave mixers are analyzed. Nonlinear capacitance, arbitrary embedding impedances, as well as shot, thermal and scattering noise arising in the diode, figure in the analysis. The anomalous mixer noise noted in millimeter-wave mixers by Kerr (1975) is shown to be explainable in terms of the correlation of down-converted components of the time-varying shot noise. A digital computer analysis of the conversion loss, noise, and output impedance of an 80-120-GHz mixer is also conducted.
ERIC Educational Resources Information Center
Rutherford, W. J.; Diemer, Gary A.; Scott, Eric D.
2011-01-01
Bioelectrical impedance analysis (BIA) is a widely used method for estimating body composition, yet issues concerning its validity persist in the literature. The purpose of this study was to validate percentage of body fat (BF) values estimated from BIA and skinfold (SF) with those obtained from hydrodensitometry (HD). Percent BF values measured…
Bedogni, Giorgio; Grugni, Graziano; Tringali, Gabriella; Agosti, Fiorenza; Sartorio, Alessandro
2015-01-01
Fat-free mass (FFM) is lower in obese subjects with Prader-Willi syndrome (PWS) than in obese subjects without PWS. FFM prediction equations developed in non-PWS subjects may, thus, not work in PWS subjects. To test whether the estimation of FFM from bioelectrical impedance analysis (BIA) in PWS subjects requires population-specific equations. Using dual-energy X-ray absorptiometry, this study measured FFM in 27 PWS and 56 non-PWS obese women and evaluated its association with the impedance index at 50 kHz (ZI50), i.e. the ratio between squared height and whole-body impedance at 50 kHz. At the same level of ZI50, PWS women had a lower FFM than non-PWS women. However, when PWS-specific equations were used, FFM was accurately estimated at the population level. An equation employing a dummy variable coding for PWS status was able to explain 85% of the variance of FFM with a root mean squared error of 3.3 kg in the pooled sample (n = 83). Population-specific equations are needed to estimate FFM from BIA in obese PWS women.
Pressure transfer function of a JT15D nozzle due to acoustic and convected entropy fluctuations
NASA Astrophysics Data System (ADS)
Miles, J. H.
An acoustic transmission matrix analysis of sound propagation in a variable area duct with and without flow is extended to include convected entropy fluctuations. The boundary conditions used in the analysis are a transfer function relating entropy and pressure at the nozzle inlet and the nozzle exit impedance. The nozzle pressure transfer function calculated is compared with JT15D turbofan engine nozzle data. The one dimensional theory for sound propagation in a variable area nozzle with flow but without convected entropy is good at the low engine speeds where the nozzle exit Mach number is low (M=0.2) and the duct exit impedance model is good. The effect of convected entropy appears to be so negligible that it is obscured by the inaccuracy of the nozzle exit impedance model, the lack of information on the magnitude of the convected entropy and its phase relationship with the pressure, and the scatter in the data. An improved duct exit impedance model is required at the higher engine speeds where the nozzle exit Mach number is high (M=0.56) and at low frequencies (below 120 Hz).
NASA Astrophysics Data System (ADS)
Glenneberg, Jens; Bardenhagen, Ingo; Langer, Frederieke; Busse, Matthias; Kun, Robert
2017-08-01
In this paper we present investigations on the morphological and electrochemical changes of lithium phosphorous oxynitride (LiPON) under mechanically bent conditions. Therefore, two types of electrochemical cells with LiPON thin films were prepared by physical vapor deposition. First, symmetrical cells with two blocking electrodes (Cu/LiPON/Cu) were fabricated. Second, to simulate a more application-related scenario cells with one blocking and one non-blocking electrode (Cu/LiPON/Li/Cu) were analyzed. In order to investigate mechanical distortion induced transport property changes in LiPON layers the cells were deposited on a flexible polyimide substrate. Morphology of the as-prepared samples and deviations from the initial state after applying external stress by bending the cells over different radii were investigated by Focused Ion Beam- Scanning Electron Microscopy (FIB-SEM) cross-section and surface images. Mechanical stress induced changes in the impedance were evaluated by time-resolved electrochemical impedance spectroscopy (EIS). Due to the formation of a stable, ion-conducting solid electrolyte interphase (SEI), cells with lithium show decreased impedance values. Furthermore, applying mechanical stress to the cells results in a further reduction of the electrolyte resistance. These results are supported by finite element analysis (FEA) simulations.
Langley, Robin S; Cotoni, Vincent
2010-04-01
Large sections of many types of engineering construction can be considered to constitute a two-dimensional periodic structure, with examples ranging from an orthogonally stiffened shell to a honeycomb sandwich panel. In this paper, a method is presented for computing the boundary (or edge) impedance of a semi-infinite two-dimensional periodic structure, a quantity which is referred to as the direct field boundary impedance matrix. This terminology arises from the fact that none of the waves generated at the boundary (the direct field) are reflected back to the boundary in a semi-infinite system. The direct field impedance matrix can be used to calculate elastic wave transmission coefficients, and also to calculate the coupling loss factors (CLFs), which are required by the statistical energy analysis (SEA) approach to predicting high frequency vibration levels in built-up systems. The calculation of the relevant CLFs enables a two-dimensional periodic region of a structure to be modeled very efficiently as a single subsystem within SEA, and also within related methods, such as a recently developed hybrid approach, which couples the finite element method with SEA. The analysis is illustrated by various numerical examples involving stiffened plate structures.
Quantitative evaluation method for differentiation of C2C12 myoblasts by ultrasonic microscopy
NASA Astrophysics Data System (ADS)
Takanashi, Kyoichi; Washiya, Mamoru; Ota, Kazuki; Yoshida, Sachiko; Hozumi, Naohiro; Kobayashi, Kazuto
2017-07-01
Cell differentiation was evaluated by ultrasonic microscopy. However, there were some regions that showed a lower acoustic impedance than the culture liquid. It was considered that, in such regions, the cells were not perfectly in contact with the film substrate. Hence, a waveform analysis was performed, and compensated acoustic impedances in such regions were in a reasonable range of values. By the same analysis, the displacements of partially floated cells were also successfully calculated. The elapsed day transitions of the compensated acoustic impedances and displacements were successfully evaluated. In the process of differentiation, actin fibers comprising the cytoskeleton are supposed to loosen in order to induce cellular fusion. In addition, the progress in cell differentiation accompanied by a change into a three-dimensional structure can partially be assessed by the displacement between a cell and a cultured film. Hence, we believe that cell differentiation can be evaluated using an ultrasonic microscope.
NASA Astrophysics Data System (ADS)
Koenig, T. W.; Olson, D. L.; Mishra, B.; King, J. C.; Fletcher, J.; Gerstenberger, L.; Lawrence, S.; Martin, A.; Mejia, C.; Meyer, M. K.; Kennedy, R.; Hu, L.; Kohse, G.; Terry, J.
2011-06-01
To create an in-situ, real-time method of monitoring neutron damage within a nuclear reactor core, irradiated silicon carbide samples are examined to correlate measurable variations in the material properties with neutron fluence levels experienced by the silicon carbide (SiC) during the irradiation process. The reaction by which phosphorus doping via thermal neutrons occurs in the silicon carbide samples is known to increase electron carrier density. A number of techniques are used to probe the properties of the SiC, including ultrasonic and Hall coefficient measurements, as well as high frequency impedance analysis. Gamma spectroscopy is also used to examine residual radioactivity resulting from irradiation activation of elements in the samples. Hall coefficient measurements produce the expected trend of increasing carrier concentration with higher fluence levels, while high frequency impedance analysis shows an increase in sample impedance with increasing fluence.
Process for structural geologic analysis of topography and point data
Eliason, Jay R.; Eliason, Valerie L. C.
1987-01-01
A quantitative method of geologic structural analysis of digital terrain data is described for implementation on a computer. Assuming selected valley segments are controlled by the underlying geologic structure, topographic lows in the terrain data, defining valley bottoms, are detected, filtered and accumulated into a series line segments defining contiguous valleys. The line segments are then vectorized to produce vector segments, defining valley segments, which may be indicative of the underlying geologic structure. Coplanar analysis is performed on vector segment pairs to determine which vectors produce planes which represent underlying geologic structure. Point data such as fracture phenomena which can be related to fracture planes in 3-dimensional space can be analyzed to define common plane orientation and locations. The vectors, points, and planes are displayed in various formats for interpretation.
Vector analysis of postcardiotomy behavioral phenomena.
Caston, J C; Miller, W C; Felber, W J
1975-04-01
The classification of postcardiotomy behavioral phenomena in Figure 1 is proposed for use as a clinical instrument to analyze etiological determinants. The utilization of a vector analysis analogy inherently denies absolutism. Classifications A-P are presented as prototypes of certain ratio imbalances of the metabolic, hemodynamic, environmental, and psychic vectors. Such a system allows for change from one type to another according to the individuality of the patient and the highly specific changes in his clinical presentation. A vector analysis also allows for infinite intermediary ratio imbalances between classification types as a function of time. Thus, postcardiotomy behavioral phenomena could be viewed as the vector summation of hemodynamic, metabolic, environmental, and psychic processes at a given point in time. Elaboration of unknown determinants in this complex syndrome appears to be task for the future.
Managing the resilience space of the German energy system - A vector analysis.
Schlör, Holger; Venghaus, Sandra; Märker, Carolin; Hake, Jürgen-Friedrich
2018-07-15
The UN Sustainable Development Goals formulated in 2016 confirmed the sustainability concept of the Earth Summit of 1992 and supported UNEP's green economy transition concept. The transformation of the energy system (Energiewende) is the keystone of Germany's sustainability strategy and of the German green economy concept. We use ten updated energy-related indicators of the German sustainability strategy to analyse the German energy system. The development of the sustainable indicators is examined in the monitoring process by a vector analysis performed in two-dimensional Euclidean space (Euclidean plane). The aim of the novel vector analysis is to measure the current status of the Energiewende in Germany and thereby provide decision makers with information about the strains for the specific remaining pathway of the single indicators and of the total system in order to meet the sustainability targets of the Energiewende. Within this vector model, three vectors (the normative sustainable development vector, the real development vector, and the green economy vector) define the resilience space of our analysis. The resilience space encloses a number of vectors representing different pathways with different technological and socio-economic strains to achieve a sustainable development of the green economy. In this space, the decision will be made as to whether the government measures will lead to a resilient energy system or whether a readjustment of indicator targets or political measures is necessary. The vector analysis enables us to analyse both the government's ambitiousness, which is expressed in the sustainability target for the indicators at the start of the sustainability strategy representing the starting preference order of the German government (SPO) and, secondly, the current preference order of German society in order to bridge the remaining distance to reach the specific sustainability goals of the strategy summarized in the current preference order (CPO). Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Stupakov, Gennady; Zhou, Demin
2016-04-01
We develop a general model of coherent synchrotron radiation (CSR) impedance with shielding provided by two parallel conducting plates. This model allows us to easily reproduce all previously known analytical CSR wakes and to expand the analysis to situations not explored before. It reduces calculations of the impedance to taking integrals along the trajectory of the beam. New analytical results are derived for the radiation impedance with shielding for the following orbits: a kink, a bending magnet, a wiggler of finite length, and an infinitely long wiggler. All our formulas are benchmarked against numerical simulations with the CSRZ computer code.
Electrochemical Impedance Analysis of β-TITANIUM Alloys as Implants in Ringers Lactate Solution
NASA Astrophysics Data System (ADS)
Bhola, Rahul; Bhola, Shaily M.; Mishra, Brajendra; Olson, David L.
2010-02-01
Commercially pure titanium and two β-titanium alloys, TNZT and TMZF, have been characterized using various electrochemical techniques for their corrosion behavior in Ringers lactate solution. The variation of corrosion potential and solution pH with time has been discussed. Electrochemical Impedance Spectroscopy has been used to fit the results into a circuit model. The stability of the oxides formed on the surface of these alloys has been correlated with impedance phase angles. Cyclic Potentiodynamic Polarization has been used to compute the corrosion parameters for the alloys. TMZF is found to be a better β-alloy as compared to TNZT.
Protein Aggregation Measurement through Electrical Impedance Spectroscopy
NASA Astrophysics Data System (ADS)
Affanni, A.; Corazza, A.; Esposito, G.; Fogolari, F.; Polano, M.
2013-09-01
The paper presents a novel methodology to measure the fibril formation in protein solutions. We designed a bench consisting of a sensor having interdigitated electrodes, a PDMS hermetic reservoir and an impedance meter automatically driven by calculator. The impedance data are interpolated with a lumped elements model and their change over time can provide information on the aggregation process. Encouraging results have been obtained by testing the methodology on K-casein, a protein of milk, with and without the addition of a drug inhibiting the aggregation. The amount of sample needed to perform this measurement is by far lower than the amount needed by fluorescence analysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stupakov, Gennady; Zhou, Demin
2016-04-21
We develop a general model of coherent synchrotron radiation (CSR) impedance with shielding provided by two parallel conducting plates. This model allows us to easily reproduce all previously known analytical CSR wakes and to expand the analysis to situations not explored before. It reduces calculations of the impedance to taking integrals along the trajectory of the beam. New analytical results are derived for the radiation impedance with shielding for the following orbits: a kink, a bending magnet, a wiggler of finite length, and an infinitely long wiggler. All our formulas are benchmarked against numerical simulations with the CSRZ computer code.
Fore, Joe; Wiechers, Ilse R; Cook-Deegan, Robert
2006-01-01
Introduction Polymerase chain reaction (PCR) was a seminal genomic technology discovered, developed, and patented in an industry setting. Since the first of its core patents expired in March, 2005, we are in a position to view the entire lifespan of the patent, examining how the intellectual property rights have impacted its use in the biomedical community. Given its essential role in the world of molecular biology and its commercial success, the technology can serve as a case study for evaluating the effects of patenting biological research tools on biomedical research. Case description Following its discovery, the technique was subjected to two years of in-house development, during which issues of inventorship and publishing/patenting strategies caused friction between members of the development team. Some have feared that this delay impeded subsequent research and may have been due to trade secrecy or the desire for obtaining lucrative intellectual property rights. However, our analysis of the history indicates that the main reasons for the delay were benign and were primarily due to difficulties in perfecting the PCR technique. Following this initial development period, the technology was made widely available, but was subject to strict licensing terms and patent protection, leading to an extensive litigation history. Discussion and evaluation PCR has earned approximately $2 billion in royalties for the various rights-holders while also becoming an essential research tool. However, using citation trend analysis, we are able to see that PCR's patented status did not preclude it from being adopted in a similar manner as other non-patented genomic research tools (specifically, pBR322 cloning vector and Maxam-Gilbert sequencing). Conclusion Despite the heavy patent protection and rigid licensing schemes, PCR seems to have disseminated so widely because of the practices of the corporate entities which have controlled these patents, namely through the use of business partnerships and broad corporate licensing, adaptive licensing strategies, and a "rational forbearance" from suing researchers for patent infringement. While far from definitive, our analysis seems to suggest that, at least in the case of PCR, patenting of genomic research tools need not impede their dissemination, if the technology is made available through appropriate business practices. PMID:16817955
Recent Selected Papers of Northwestern Polytechnical University in Two Parts, Part II.
1981-08-28
OF CONTENTS Page Dual Properties of Elastic Structures 1 Matrix Analysis of Wings 76 On a Method for the Determination of Plane Stress Fracture...I= Ea]{(x, v,z) j l~i l’m mini The equation above means that the cisplacement function vector determines the strain function vector. (Assumption II...means that the distributed load function vector is determined by the stress function vector. In Section 1, there was an analysis of a three
ERIC Educational Resources Information Center
Elk, Seymour B.
1997-01-01
Suggests that the cross product of two vectors can be more easily and accurately explained by starting from the perspective of dyadics because then the concept of vector multiplication has a simple geometrical picture that encompasses both the dot and cross products in any number of dimensions in terms of orthogonal unit vector components. (AIM)
Dielectric, Impedance and Conduction Behavior of Double Perovskite Pr2CuTiO6 Ceramics
NASA Astrophysics Data System (ADS)
Mahato, Dev K.; Sinha, T. P.
2017-01-01
Polycrystalline Pr2CuTiO6 (PCT) ceramics exhibits dielectric, impedance and modulus characteristics as a possible material for microelectronic devices. PCT was synthesized through the standard solid-state reaction method. The dielectric permittivity, impedance and electric modulus of PCT have been studied in a wide frequency (100 Hz-1 MHz) and temperature (303-593 K) range. Structural analysis of the compound revealed a monoclinic phase at room temperature. Complex impedance Cole-Cole plots are used to interpret the relaxation mechanism, and grain boundary contributions towards conductivity have been estimated. From electrical modulus formalism polarization and conductivity relaxation behavior in PCT have been discussed. Normalization of the imaginary part of impedance ( Z″) and the normalized imaginary part of modulus ( M″) indicates contributions from both long-range and localized relaxation effects. The grain boundary resistance along with their relaxation frequencies are plotted in the form of an Arrhenius plot with activation energy 0.45 eV and 0.46 eV, respectively. The ac conductivity mechanism has been discussed.
Broadband spectroscopy of dynamic impedances with short chirp pulses.
Min, M; Land, R; Paavle, T; Parve, T; Annus, P; Trebbels, D
2011-07-01
An impedance spectrum of dynamic systems is time dependent. Fast impedance changes take place, for example, in high throughput microfluidic devices and in operating cardiovascular systems. Measurements must be as short as possible to avoid significant impedance changes during the spectrum analysis, and as long as possible for enlarging the excitation energy and obtaining a better signal-to-noise ratio (SNR). The authors propose to use specific short chirp pulses for excitation. Thanks to the specific properties of the chirp function, it is possible to meet the needs for a spectrum bandwidth, measurement time and SNR so that the most accurate impedance spectrogram can be obtained. The chirp wave excitation can include thousands of cycles when the impedance changes slowly, but in the case of very high speed changes it can be shorter than a single cycle, preserving the same excitation bandwidth. For example, a 100 kHz bandwidth can be covered by the chirp pulse with durations from 10 µs to 1 s; only its excitation energy differs also 10(5) times. After discussing theoretical short chirp properties in detail, the authors show how to generate short chirps in the microsecond range with a bandwidth up to a few MHz by using digital synthesis architectures developed inside a low-cost standard field programmable gate array.
NASA Astrophysics Data System (ADS)
Ahad, M. A.; Rutkove, S. B.
2010-04-01
Tetrapolar surface electrical impedance methods are sensitive to changes in muscle status and can therefore provide a means for studying neuromuscular disease noninvasively. In order to better understand the relationship between surface impedance measurements and the actual muscle electrical properties, we performed measurements on 20 adult Wistar rats, 8 of which underwent sciatic nerve crush. Surface impedance measurements were performed on the left hind limb both before injury and out to 2 weeks after injury. In addition, both normal and sciatic crush animals were sacrificed and the dielectric properties of the extracted gastrocnemius muscle measured. We found that 50 kHz conductivities were greater in the animals that underwent crush than in the animals that did not. The permittivities in both directions, however, showed non-significant differences. In order to analyze the effect of these changes as well as the accompanying reduction in muscle volume, a finite element model of the hind limb was developed based on computerized tomographic imaging. The model successfully predicted the surface impedance values in the animals after crush injury and, by its inverse application, may be used to help determine the underlying electrical properties of muscle in various neuromuscular diseases based on surface impedance data.
Impedance dispersion analysis of drug-membrane interactions
NASA Astrophysics Data System (ADS)
Tacheva, Bilyana; Paarvanova, Boyana; Ivanov, Ivan T.; Karabaliev, Miroslav
2017-11-01
Thin lipid films modified glassy carbon electrodes (GCE) were used in this work as model system for studying the interactions between two antipsychotic phenothiazine drugs, chlorpromazine and thioridazine, and the lipid fraction of the biomembranes. The lipid films on the electrode surface were obtained through the thinning of film-forming lipid solution deposited between an electrolyte phase and the working GC electrode. The effects of the drugs on the lipid film structure were investigated by electrochemical impedance spectroscopy (EIS). To characterize the electric properties of the lipid film the impedance of the working GCE is modeled with an equivalent circuit consisting of parallel capacitance Cp and resistance Rp. These capacitance and resistance are not frequency independent but could be calculated as equivalent Cp and Rp for each measured frequency of the impedance spectrum and presented as functions of the frequency f, Cp = Cp(f) and Rp= Rp(f). For the lipid films used in this work, it is demonstrated that both Cp(f) and Rp(f) are well approximated with power-law functions. This behavior implies that the impedance Z of the films could be analysed in terms of the well-known constant-phase angle element (CPE), which is often used to describe the interfacial impedance of solid working electrodes.
NASA Astrophysics Data System (ADS)
Pavlov, L'uboš; Skurčák, L'uboš; Chovanec, Juraj; Altus, Juraj
2017-11-01
This article is devoted to the analysis of the possible influence of impedance asymmetry on the efficiency of electricity transmission and distribution in the electricity system in Slovakia, at a voltage level of 110 kV - 400 kV, using synchronic phasor monitoring results. For simplicity of calculations, in practice, the impedance imbalance from mutual interfacial inductive capacitances bonds is neglected. In this way, the 3-phase network is interpreted as symmetrical in the calculations. In this case, it is possible to determine only some components of losses (ohmic losses, corona loss, leakages, etc). The influence of impedance asymmetry can be quantified by calculation using the results of the monitoring of the synchronous phasors of selected electricity system elements (OHL, transformer, choke) or by 3-phase modelling of real system elements. frequency to test the transformer for induced over voltage test, and its characteristics is analysed.
A Wireless Multi-Sensor Dielectric Impedance Spectroscopy Platform
Ghaffari, Seyed Alireza; Caron, William-O.; Loubier, Mathilde; Rioux, Maxime; Viens, Jeff; Gosselin, Benoit; Messaddeq, Younes
2015-01-01
This paper describes the development of a low-cost, miniaturized, multiplexed, and connected platform for dielectric impedance spectroscopy (DIS), designed for in situ measurements and adapted to wireless network architectures. The platform has been tested and used as a DIS sensor node on ZigBee mesh and was able to interface up to three DIS sensors at the same time and relay the information through the network for data analysis and storage. The system is built from low-cost commercial microelectronics components, performs dielectric spectroscopy ranging from 5 kHz to 100 kHz, and benefits from an on-the-fly calibration system that makes sensor calibration easy. The paper describes the microelectronics design, the Nyquist impedance response, the measurement sensitivity and accuracy, and the testing of the platform for in situ dielectric impedance spectroscopy applications pertaining to fertilizer sensing, water quality sensing, and touch sensing. PMID:26393587
NASA Astrophysics Data System (ADS)
Gerngross, M.-D.; Carstensen, J.; Föll, H.; Adelung, R.
2016-01-01
This paper reports on the characterization of the electrochemical growth process of magnetic nanowires in ultra-high-aspect ratio InP membranes via in situ fast Fourier transform impedance spectroscopy in a typical frequency range from 75 Hz to 18.5 kHz. The measured impedance data from the Ni, Co, and FeCo can be very well fitted using the same electric equivalent circuit consisting of a series resistance in serial connection to an RC-element and a Maxwell element. The impedance data clearly indicate the similarities in the growth behavior of Ni, Co and FeCo nanowires in ultra-high aspect ratio InP membranes—the beneficial impact of boric acid on the metal deposition in ultra-high aspect ratio membranes and the diffusion limitation of boric acid, as well as differences such as passivation or side reactions.
NASA Astrophysics Data System (ADS)
Aleksanyan, Grayr; Shcherbakov, Ivan; Kucher, Artem; Sulyz, Andrew
2018-04-01
Continuous monitoring of the patient's breathing by the method of multi-angle electric impedance tomography allows to obtain images of conduction change in the chest cavity during the monitoring. Direct analysis of images is difficult due to the large amount of information and low resolution images obtained by multi-angle electrical impedance tomography. This work presents a method for obtaining a graph of respiratory activity of the lungs based on the results of continuous lung monitoring using the multi-angle electrical impedance tomography method. The method makes it possible to obtain a graph of the respiratory activity of the left and right lungs separately, as well as a summary graph, to which it is possible to apply methods of processing the results of spirography.
Huguel, Benjamin; Vaugrenard, Thibaud; Saby, Ludivine; Benhamou, Lionel; Arméro, Sébastien; Camilleri, Élise; Langar, Aida; Alitta, Quentin; Grino, Michel; Retornaz, Frédérique
2018-06-01
Chronic heart failure (CHF) is a major public health matter. Mainly affecting the elderly, it is responsible for a high rate of hospitalization due to the frequency of acute heart failure (ADHF). This represents a disabling pathology for the patient and very costly for the health care system. Our study is designed to assess a connected and portable bioelectrical impedance analysis (BIA) that could reduce these hospitalizations by preventing early ADHF. This prospective study included patients hospitalized in cardiology for ADHF. Patients achieved 3 self-measurements using the BIA during their hospitalization and answered a questionnaire evaluating the acceptability of this self-measurement. The results of these measures were compared with the clinical, biological and echocardiographic criteria of patients at the same time. Twenty-three patients were included, the self-measurement during the overall duration of the hospitalization was conducted autonomously by more than 80% of the patients. The acceptability (90%) for the use of the portable BIA was excellent. Some correlations were statistically significant, such as the total water difference to the weight difference (p=0.001). There were common trends between the variation of impedance analysis measures and other evaluation criteria. The feasibility and acceptability of a self-measurement of bioelectrical impedance analysis by the patient in AHF opens up major prospects in the management of monitoring patients in CHF. The interest of this tool is the prevention of ADHF leading to hospitalization or re-hospitalizations now requires to be presented by new studies.
Ohta, Megumi; Midorikawa, Taishi; Hikihara, Yuki; Masuo, Yoshihisa; Sakamoto, Shizuo; Torii, Suguru; Kawakami, Yasuo; Fukunaga, Tetsuo; Kanehisa, Hiroaki
2017-02-01
This study examined the validity of segmental bioelectrical impedance (BI) analysis for predicting the fat-free masses (FFMs) of whole-body and body segments in children including overweight individuals. The FFM and impedance (Z) values of arms, trunk, legs, and whole body were determined using a dual-energy X-ray absorptiometry and segmental BI analyses, respectively, in 149 boys and girls aged 6 to 12 years, who were divided into model-development (n = 74), cross-validation (n = 35), and overweight (n = 40) groups. Simple regression analysis was applied to (length) 2 /Z (BI index) for each of the whole-body and 3 segments to develop the prediction equations of the measured FFM of the related body part. In the model-development group, the BI index of each of the 3 segments and whole body was significantly correlated to the measured FFM (R 2 = 0.867-0.932, standard error of estimation = 0.18-1.44 kg (5.9%-8.7%)). There was no significant difference between the measured and predicted FFM values without systematic error. The application of each equation derived in the model-development group to the cross-validation and overweight groups did not produce significant differences between the measured and predicted FFM values and systematic errors, with an exception that the arm FFM in the overweight group was overestimated. Segmental bioelectrical impedance analysis is useful for predicting the FFM of each of whole-body and body segments in children including overweight individuals, although the application for estimating arm FFM in overweight individuals requires a certain modification.
NASA Astrophysics Data System (ADS)
Cao, Pei; Qi, Shuai; Tang, J.
2018-03-01
The impedance/admittance measurements of a piezoelectric transducer bonded to or embedded in a host structure can be used as damage indicator. When a credible model of the healthy structure, such as the finite element model, is available, using the impedance/admittance change information as input, it is possible to identify both the location and severity of damage. The inverse analysis, however, may be under-determined as the number of unknowns in high-frequency analysis is usually large while available input information is limited. The fundamental challenge thus is how to find a small set of solutions that cover the true damage scenario. In this research we cast the damage identification problem into a multi-objective optimization framework to tackle this challenge. With damage locations and severities as unknown variables, one of the objective functions is the difference between impedance-based model prediction in the parametric space and the actual measurements. Considering that damage occurrence generally affects only a small number of elements, we choose the sparsity of the unknown variables as another objective function, deliberately, the l 0 norm. Subsequently, a multi-objective Dividing RECTangles (DIRECT) algorithm is developed to facilitate the inverse analysis where the sparsity is further emphasized by sigmoid transformation. As a deterministic technique, this approach yields results that are repeatable and conclusive. In addition, only one algorithmic parameter, the number of function evaluations, is needed. Numerical and experimental case studies demonstrate that the proposed framework is capable of obtaining high-quality damage identification solutions with limited measurement information.
NASA Astrophysics Data System (ADS)
Lakshminarayanan, Abirami; Reddy, B. Uma; Raghav, Nallani; Ravi, Vijay Kumar; Kumar, Anuj; Maiti, Prabal K.; Sood, A. K.; Jayaraman, N.; Das, Saumitra
2015-10-01
A RNAi based antiviral strategy holds the promise to impede hepatitis C viral (HCV) infection overcoming the problem of emergence of drug resistant variants, usually encountered in the interferon free direct-acting antiviral therapy. Targeted delivery of siRNA helps minimize adverse `off-target' effects and maximize the efficacy of therapeutic response. Herein, we report the delivery of siRNA against the conserved 5'-untranslated region (UTR) of HCV RNA using a liver-targeted dendritic nano-vector functionalized with a galactopyranoside ligand (DG). Physico-chemical characterization revealed finer details of complexation of DG with siRNA, whereas molecular dynamic simulations demonstrated sugar moieties projecting ``out'' in the complex. Preferential delivery of siRNA to the liver was achieved through a highly specific ligand-receptor interaction between dendritic galactose and the asialoglycoprotein receptor. The siRNA-DG complex exhibited perinuclear localization in liver cells and co-localization with viral proteins. The histopathological studies showed the systemic tolerance and biocompatibility of DG. Further, whole body imaging and immunohistochemistry studies confirmed the preferential delivery of the nucleic acid to mice liver. Significant decrease in HCV RNA levels (up to 75%) was achieved in HCV subgenomic replicon and full length HCV-JFH1 infectious cell culture systems. The multidisciplinary approach provides the `proof of concept' for restricted delivery of therapeutic siRNAs using a target oriented dendritic nano-vector.A RNAi based antiviral strategy holds the promise to impede hepatitis C viral (HCV) infection overcoming the problem of emergence of drug resistant variants, usually encountered in the interferon free direct-acting antiviral therapy. Targeted delivery of siRNA helps minimize adverse `off-target' effects and maximize the efficacy of therapeutic response. Herein, we report the delivery of siRNA against the conserved 5'-untranslated region (UTR) of HCV RNA using a liver-targeted dendritic nano-vector functionalized with a galactopyranoside ligand (DG). Physico-chemical characterization revealed finer details of complexation of DG with siRNA, whereas molecular dynamic simulations demonstrated sugar moieties projecting ``out'' in the complex. Preferential delivery of siRNA to the liver was achieved through a highly specific ligand-receptor interaction between dendritic galactose and the asialoglycoprotein receptor. The siRNA-DG complex exhibited perinuclear localization in liver cells and co-localization with viral proteins. The histopathological studies showed the systemic tolerance and biocompatibility of DG. Further, whole body imaging and immunohistochemistry studies confirmed the preferential delivery of the nucleic acid to mice liver. Significant decrease in HCV RNA levels (up to 75%) was achieved in HCV subgenomic replicon and full length HCV-JFH1 infectious cell culture systems. The multidisciplinary approach provides the `proof of concept' for restricted delivery of therapeutic siRNAs using a target oriented dendritic nano-vector. Electronic supplementary information (ESI) available: Spectral data and experimental details. See DOI: 10.1039/c5nr02898a
Challenging assumptions of notational transparency: the case of vectors in engineering mathematics
NASA Astrophysics Data System (ADS)
Craig, Tracy S.
2017-11-01
The notation for vector analysis has a contentious nineteenth century history, with many different notations describing the same or similar concepts competing for use. While the twentieth century has seen a great deal of unification in vector analysis notation, variation still remains. In this paper, the two primary notations used for expressing the components of a vector are discussed in historical and current context. Popular mathematical texts use the two notations as if they are transparent and interchangeable. In this research project, engineering students' proficiency at vector analysis was assessed and the data were analyzed using the Rasch measurement method. Results indicate that the students found items expressed in unit vector notation more difficult than those expressed in parenthesis notation. The expert experience of notation as transparent and unproblematically symbolic of underlying processes independent of notation is shown to contrast with the student experience where the less familiar notation is experienced as harder to work with.
NASA Technical Reports Server (NTRS)
Hagyard, Mona J.; Stark, B. A.; Venkatakrishnan, P.
1998-01-01
A careful analysis of a 6-hour time sequence of vector magnetograms of AR 6659, observed on 1991 June 10 with the MSFC vector magnetograph, has revealed only minor changes in the vector magnetic field azimuths in the vicinity of two M-class flares, and the association of these changes with the flares is not unambiguous. In this paper we present our analysis of the data which includes comparison of vector magnetograms prior to and during the flares, calculation of distributions of the rms variation of the azimuth at each pixel in the field of view of the active region, and examination of the variation with time of the azimuths at every pixel covered by the main flare emissions as observed with the H-alpha telescope coaligned with the vector magnetograph. We also present results of an analysis of evolutionary changes in the azimuth over the field of view of the active region.
ERIC Educational Resources Information Center
Mooney, Angela; Kelsey, Laurel; Fellingham, Gilbert W.; George, James D.; Hager, Ron L.; Myrer, J. William; Vehrs, Pat R.
2011-01-01
To determine the validity and reliability of percent body fat estimates in 177 boys and 154 girls between 12-17 years of age, percent body fat was assessed once using dual-energy X-ray absorptiometry and twice using the sum of two skinfolds and three bioelectrical impedance analysis devices. The assessments were repeated on 79 participants on a…
ERIC Educational Resources Information Center
Andreacci, Joseph L.; Nagle, Trisha; Fitzgerald, Elise; Rawson, Eric S.; Dixon, Curt B.
2013-01-01
Purpose: We examined the impact that cycle ergometry exercise had on percent body fat (%BF) estimates when assessed using either leg-to-leg or segmental bioelectrical impedance analysis (LBIA; SBIA) and whether the intensity of the exercise bout impacts the %BF magnitude of change. Method: Seventy-four college-aged adults participated in this…
Chang, Kuo-Chu; Hsu, Kwan-Lih; Tseng, Yung-Zu
2003-01-01
We determined the effects of diabetes and gender on the physical properties of the vasculature in streptozotocin (STZ)-treated rats based on the aortic input impedance analysis. Rats given STZ 65 mg/kg i.v. were compared with untreated age-matched controls. Pulsatile aortic pressure and flow signals were measured and were then subjected to Fourier transformation for the analysis of aortic input impedance. Wave transit time was determined using the impulse response function of the filtered aortic input impedance spectra. Male but not female diabetic rats exhibited an increase in cardiac output in the absence of any significant changes in arterial blood pressure, resulting in a decline in total peripheral resistance. However, in each gender group, diabetes contributed to an increase in wave reflection factor, from 0.47 +/- 0.04 to 0.84 +/- 0.03 in males and from 0.46 +/- 0.03 to 0.81 +/- 0.03 in females. Diabetic rats had reduced wave transit time, at 18.82 +/- 0.60 vs 21.34 +/- 0.51 msec in males and at 19.63 +/- 0.37 vs 22.74 +/- 0.57 msec in females. Changes in wave transit time and reflection factor indicate that diabetes can modify the timing and magnitude of the wave reflection in the rat arterial system. Meanwhile, diabetes produced a fall in aortic characteristic impedance from 0.023 +/- 0.002 to 0.009 +/- 0.001 mmHg/min/kg/ml in males and from 0.028 +/- 0.002 to 0.014 +/- 0.001 mmHg/min/kg/ml in females. With unaltered aortic pressure, both the diminished aortic characteristic impedance and wave transit time suggest that the muscle inactivation in diabetes may occur in aortas and large arteries and may cause a detriment to the aortic distensibility in rats with either sex. We conclude that only rats with male gender diabetes produce a detriment to the physical properties of the resistance arterioles. In spite of male or female gender, diabetes decreases the aortic distensibility and impairs the wave reflection phenomenon in the rat arterial system.
Reilly, Carolyn Miller; Higgins, Melinda; Smith, Andrew; Culler, Steven D; Dunbar, Sandra B
2015-11-01
This paper presents a secondary in-depth analysis of five persons with heart failure randomized to receive an education and behavioral intervention on fluid restriction as part of a larger study. Using a single subject analysis design, time series analyses models were constructed for each of the five patients for a period of 180 days to determine correlations between daily measures of patient reported fluid intake, thoracic impedance, and weights, and relationships between patient reported outcomes of symptom burden and health related quality of life over time. Negative relationships were observed between fluid intake and thoracic impedance, and between impedance and weight, while positive correlations were observed between daily fluid intake and weight. By constructing time series analyses of daily measures of fluid congestion, trends and patterns of fluid congestion emerged which could be used to guide individualized patient care or future research endeavors. Employment of such a specialized analysis technique allows for the elucidation of clinically relevant findings potentially disguised when only evaluating aggregate outcomes of larger studies. Copyright © 2015 Elsevier Inc. All rights reserved.
Yılmaz, Dilek; Sönmez, Ferah; Karakaş, Sacide; Yavaşcan, Önder; Aksu, Nejat; Ömürlü, İmran Kurt; Yenisey, Çiğdem
2016-06-01
Malnutrition is one of the major causes of morbidity and mortality in children with chronic kidney disease (CKD). The objective of this study was to evaluate nutritional status of children with stage 3-4 CKD and treated by peritoneal dialysis or hemodialysis using anthropometric measurements, biochemical parameters and bioelectrical impedance analysis. The study included a total of 52 patients and 46 healthy children. In anthropometric evaluation, the children with CKD had lower values for standard deviation score for weight, height, body mass index, skinfold thickness and mid-arm circumference than those of healthy children (p < 0.05). The fat mass (%) and the body cell mass (%) measurements performed by bioelectrical impedance analysis were lower compared with the control group (p < 0.05). It is considered that bioelectrical impedance analysis measurement should be used with anthropometric measurements, which are easy to perform, to achieve more accurate nutritional evaluation in children. © The Author [2016]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Investigations on structural and giant magneto impedance properties of Zn3(VO4)2 nanorods
NASA Astrophysics Data System (ADS)
Malaidurai, M.; Bulusu, Venkat; De, Sourodeep; Thangavel, R.
2018-05-01
In this paper, we successfully synthesized Zn3(VO4)2 novel nanorods by hydrothermal method. As mixed phase of Zn3(VO4)2 structural and phase transformations were monitored in crystal lattice with different ionic strength by X-ray diffraction(XRD). The Zn3(VO4)2 thin film formation validated through qualitative and quantitative analysis by FESEM and it is clearly depicted the formation of the Zn3(VO4)2 nanorods varied from ˜100nm in lengths and ˜30 nm in widths. The Zn precursor's anions directly influence the composition and shape of the resultant hydrated Zn3(VO4)2. Impedance analysis were closely studied with Impedance-Frequency characterization, which was then followed by a dielectric measurement. The analysis of GMI effect was carried out with the help of the model equivalent circuit at low frequencies, constant phase element (CPE). GMI effect and the sensitivity are calculated for the sample by appling magnetic field and driving frequency in order to analyze the giant magnetoimpedance resistance of grain boundaries for spintronics applications.
Portfolio Analysis for Vector Calculus
ERIC Educational Resources Information Center
Kaplan, Samuel R.
2015-01-01
Classic stock portfolio analysis provides an applied context for Lagrange multipliers that undergraduate students appreciate. Although modern methods of portfolio analysis are beyond the scope of vector calculus, classic methods reinforce the utility of this material. This paper discusses how to introduce classic stock portfolio analysis in a…
Ferreira, J; Seoane, F; Lindecrantz, K
2013-01-01
Personalised Health Systems (PHS) that could benefit the life quality of the patients as well as decreasing the health care costs for society among other factors are arisen. The purpose of this paper is to study the capabilities of the System-on-Chip Impedance Network Analyser AD5933 performing high speed single frequency continuous bioimpedance measurements. From a theoretical analysis, the minimum continuous impedance estimation time was determined, and the AD5933 with a custom 4-Electrode Analog Front-End (AFE) was used to experimentally determine the maximum continuous impedance estimation frequency as well as the system impedance estimation error when measuring a 2R1C electrical circuit model. Transthoracic Electrical Bioimpedance (TEB) measurements in a healthy subject were obtained using 3M gel electrodes in a tetrapolar lateral spot electrode configuration. The obtained TEB raw signal was filtered in MATLAB to obtain the respiration and cardiogenic signals, and from the cardiogenic signal the impedance derivative signal (dZ/dt) was also calculated. The results have shown that the maximum continuous impedance estimation rate was approximately 550 measurements per second with a magnitude estimation error below 1% on 2R1C-parallel bridge measurements. The displayed respiration and cardiac signals exhibited good performance, and they could be used to obtain valuable information in some plethysmography monitoring applications. The obtained results suggest that the AD5933-based monitor could be used for the implementation of a portable and wearable Bioimpedance plethysmograph that could be used in applications such as Impedance Cardiography. These results combined with the research done in functional garments and textile electrodes might enable the implementation of PHS applications in a relatively short time from now.
Chang, Yau-Zen; Liu, Mou-Chuan; Pai, Che-An; Lin, Chun-Li; Yen, Kuang-I
2011-06-01
This study investigates the application of non-destructive testing based on the impedance theory in the cyclic fatigue evaluation of endodontic Ni-Ti rotary instruments. Fifty Ni-Ti ProTaper instruments were divided into five groups (n=10 in Groups A to E). Groups A to D were subjected to cyclic fatigue within an artificial canal (Group E was the control group). The mean value of the total life limit (TLL), defined as the instrument being rotated until fracture occurred was found to be 104 s in Group A. Each rotary instrument in Groups B, C and D were rotated until the tested instruments reached 80% (84 s), 60% (62 s) and 40% (42 s) of the TLL. After fatigue testing, each rotary instrument was mounted onto a custom-developed non-destructive testing device to give the tip of the instrument a progressive sideways bend in four mutually perpendicular directions to measure the corresponding impedance value (including the resistance and the reactance). The results indicated that the impedance value showed the same trend as the resistance, implying that the impedance was primarily affected by the resistance. The impedance value for the instruments in the 80% and 60% TLL groups increased by about 6 mΩ (about 7.5%) more than that of the instruments in the intact and 40% TLL groups. The SEM analysis result showed that crack striations were only found at the tip of the thread on the cracked surface of the instrument, consistent with the impedance measurements that found the impedance value of the cracked surface to be significantly different from those in other surfaces. These findings indicate that the impedance value may represent an effective parameter for evaluating the micro-structural status of Ni-Ti rotary instruments subjected to fatigue loading. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.
van der Burg, Pauline S; Miedema, Martijn; de Jongh, Frans H; Frerichs, Inez; van Kaam, Anton H
2014-06-01
Electrical impedance tomography measures lung volume in a cross-sectional slice of the lung. Whether these cross-sectional volume changes are representative of the whole lung has only been investigated in adults, showing conflicting results. This study aimed to compare cross-sectional and whole lung volume changes using electrical impedance tomography and respiratory inductive plethysmography. A prospective, single-center, observational, nonrandomized study. The study was conducted in a neonatal ICU in the Netherlands. High-frequency ventilated preterm infants with respiratory distress syndrome. Cross-sectional and whole lung volume changes were continuously and simultaneously measured by, respectively, electrical impedance tomography and respiratory inductive plethysmography during a stepwise recruitment procedure. End-expiratory lung volume changes were assessed by mapping the inflation and deflation limbs using both the pressure/impedance and pressure/inductance pairs and characterized by calculating the inflection points. In addition, oscillatory tidal volume changes were assessed at each pressure step. Twenty-three infants were included in the study. Of these, eight infants had to be excluded because the quality of the registration was insufficient for analysis (two electrical impedance tomography and six respiratory inductive plethysmography). In the remaining 15 infants (gestational age 28.0 ± 2.6 wk; birth weight 1,027 ± 514 g), end-expiratory lung volume changes measured by electrical impedance tomography were significantly correlated to respiratory inductive plethysmography measurements in 12 patients (mean r = 0.93 ± 0.05). This was also true for the upper inflection point on the inflation (r = 0.91, p < 0.01) and deflation limb (r = 0.83, p < 0.01). In 13 patients, impedance and inductance data also correlated significantly on oscillatory tidal volume/pressure relationships (mean r = 0.81 ± 0.18). This study shows that cross-sectional lung volume changes measured by electrical impedance tomography are representative for the whole lung and that this concept also applies to newborn infants.
Poynting vector measurements of electromagnetic ion cyclotron waves in the plasmasphere
NASA Technical Reports Server (NTRS)
Labelle, J.; Treumann, R. A.
1992-01-01
Results are presented from an analysis of the June 6, 1985 Pc 2 measurements for which E, B, and delta-N were all analyzed. The event occurred in the duskside overlap region between the plasmaspheric bulge and the ion ring current. Results of the Poynting vector analysis of the R and L mode components show both of them to be characterized by northward Poynting vector, indicating energy flux away from the equator. The value of the Poynting vector was found to be about 3 microW/sq m.
Ward, L; Cornish, B H; Paton, N I; Thomas, B J
1999-11-01
It has been proposed that multiple frequency bioelectrical impedance models of the human body should include an inductive property for the circulatory system, the inductor circuit model (ICM), and that such a model, when coupled with a new method of data analysis, can improve the predictive power of multiple frequency bioelectrical impedance analysis (MFBIA). This hypothesis was tested using MFBIA measurements and gold standard measures of total body and extracellular water volumes in a cross-validation study in two subject groups (viz. controls and HIV). The MFBIA measurements were analysed using the current, widely accepted Cole model and the alternative ICM model which includes an inductive component. Correlations in the range 0.75 to 0.92 (for TBW) and 0.46 to 0.79 (for ECW) for impedance quotients versus gold standard measures within the subject groups were observed. These decreased, to as low as r = 0.50 for TBW and r = 0.29 for ECW, when the derived algorithms were applied to the alternative subject group. These results suggest that lack of portability of MFBIA algorithms between subject groups is not due to an inadequacy of the analogue circuit model per se but is possibly due more to fundamental flaws in the principles associated with its application. These include assuming a constant proportionality of body segment geometries and tissue fluid resistivities. This study has also demonstrated that this inadequacy cannot be overcome by simply introducing an inductive component into the analogue electrical circuit.
Antenna-load interactions at optical frequencies: impedance matching to quantum systems.
Olmon, R L; Raschke, M B
2012-11-09
The goal of antenna design at optical frequencies is to deliver optical electromagnetic energy to loads in the form of, e.g., atoms, molecules or nanostructures, or to enhance the radiative emission from such structures, or both. A true optical antenna would, on a qualitatively new level, control the light-matter interaction on the nanoscale for controlled optical signal transduction, radiative decay engineering, quantum coherent control, and super-resolution microscopy, and provide unprecedented sensitivity in spectroscopy. Resonant metallic structures have successfully been designed to approach these goals. They are called optical antennas in analogy to radiofrequency (RF) antennas due to their capability to collect and control electromagnetic fields at optical frequencies. However, in contrast to the RF, where exact design rules for antennas, waveguides, and antenna-load matching in terms of their impedances are well established, substantial physical differences limit the simple extension of the RF concepts into the optical regime. Key distinctions include, for one, intrinsic material resonances including quantum state excitations (metals, metal oxides, semiconductor homo- and heterostructures) and extrinsic resonances (surface plasmon/phonon polaritons) at optical frequencies. Second, in the absence of discrete inductors, capacitors, and resistors, new design strategies must be developed to impedance match the antenna to the load, ultimately in the form of a vibrational, electronic, or spin excitation on the quantum level. Third, there is as yet a lack of standard performance metrics for characterizing, comparing and quantifying optical antenna performance. Therefore, optical antenna development is currently challenged at all the levels of design, fabrication, and characterization. Here we generalize the ideal antenna-load interaction at optical frequencies, characterized by three main steps: (i) far-field reception of a propagating mode exciting an antenna resonance, (ii) subsequent transformation of that mode into a nanoscale spatial localization, and (iii) near-field coupling via an enhanced local density of states to a quantum load. These three steps define the goal of efficient transformation of incident radiation into a quantum excitation in an impedance-matched fashion. We review the physical basis of the light-matter interaction at the transition from the RF to optical regime, discuss the extension of antenna theory as needed for the design of impedance-matched optical antenna-load coupled systems, and provide several examples of the state of the art in design strategies and suggest future extensions. We furthermore suggest new performance metrics based on the combination of electric vector field, field enhancement and capture cross section measurement to aid in comparison between different antenna designs and optimization of optical antenna performance within the physical parameter space.
NASA Astrophysics Data System (ADS)
Mushlihuddin, R.; Nurafifah; Irvan
2018-01-01
The student’s low ability in mathematics problem solving proved to the less effective of a learning process in the classroom. Effective learning was a learning that affects student’s math skills, one of which is problem-solving abilities. Problem-solving capability consisted of several stages: understanding the problem, planning the settlement, solving the problem as planned, re-examining the procedure and the outcome. The purpose of this research was to know: (1) was there any influence of PBL model in improving ability Problem solving of student math in a subject of vector analysis?; (2) was the PBL model effective in improving students’ mathematical problem-solving skills in vector analysis courses? This research was a quasi-experiment research. The data analysis techniques performed from the test stages of data description, a prerequisite test is the normality test, and hypothesis test using the ANCOVA test and Gain test. The results showed that: (1) there was an influence of PBL model in improving students’ math problem-solving abilities in vector analysis courses; (2) the PBL model was effective in improving students’ problem-solving skills in vector analysis courses with a medium category.
Experimental study of Bloch vector analysis in nonlinear, finite, dissipative systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
D'Aguanno, G.; Mattiucci, N.; C. M. Bowden Facility, Building 7804, RDECOM, Redstone Arsenal, Alabama 35898
2010-01-15
We have investigated and experimentally demonstrated the applicability of the Bloch vector for one-dimensional, nonlinear, finite, dissipative systems. The case studied is the second harmonic generation from metallodielectric multilayer filters. In particular, we have applied the Bloch vector analysis to Ag/Ta{sub 2}O{sub 5} thin-film multilayer samples and shown the importance of the phase matching calculated through the Bloch vector. The nonlinear coefficients extracted from experimental results are consistent with previous studies. Nowadays, metal-based nanostructures play a fundamental role in nonlinear nanophotonics and nanoplasmonics. Our results clearly suggest that even in these forefront fields the Bloch vector continues to play anmore » essential role.« less
Yata, Teerapong; Lee, Eugene L Q; Suwan, Keittisak; Syed, Nelofer; Asavarut, Paladd; Hajitou, Amin
2015-06-03
Gene therapy has been an attractive paradigm for cancer treatment. However, cancer gene therapy has been challenged by the inherent limitation of vectors that are able to deliver therapeutic genes to tumors specifically and efficiently following systemic administration. Bacteriophage (phage) are viruses that have shown promise for targeted systemic gene delivery. Yet, they are considered poor vectors for gene transfer. Recently, we generated a tumor-targeted phage named adeno-associated virus/phage (AAVP), which is a filamentous phage particle whose genome contains the adeno-associated virus genome. Its effectiveness in delivering therapeutic genes to tumors specifically both in vitro and in vivo has been shown in numerous studies. Despite being a clinically useful vector, a multitude of barriers impede gene transduction to tumor cells. We hypothesized that one such factor is the tumor extracellular matrix (ECM). We used a number of tumor cell lines from different species and histological types in 2D monolayers or 3D multicellular tumor spheroid (MCTS) models. To assess whether the ECM is a barrier to tumor cell targeting by AAVP, we depleted the ECM using collagenase, hyaluronidase, or combination of both. We employed multiple techniques to investigate and quantify the effect of ECM depletion on ECM composition (including collagen type I, hyaluronic acid, fibronectin and laminin), and how AAVP adsorption, internalisation, gene expression and therapeutic efficacy are subsequently affected. Data were analyzed using a student's t test when comparing two groups or one-way ANOVA and post hoc Tukey tests when using more than two groups. We demonstrate that collagenase and hyaluronidase-mediated degradation of tumor ECM affects the composition of collagen, hyaluronic acid and fibronectin. Consequently, AAVP diffusion, internalisation, gene expression and tumor cell killing were enhanced after enzymatic treatment. Our data suggest that enhancement of gene transfer by the AAVP is solely attributed to ECM depletion. We provide substantial evidence that ECM modulation is relevant in clinically applicable settings by using 3D MCTS, which simulates in vivo environments more accurately. Our findings suggest that ECM depletion is an effective strategy to enhance the efficiency of viral vector-guided gene therapy.
NASA Astrophysics Data System (ADS)
Sekiguchi, Atsushi
2013-03-01
The QCM method allows measurements of impedance, an index of swelling layer viscosity in a photoresist during development. While impedance is sometimes used as a qualitative index of change in the viscosity of the swelling layer, it has to date not been used quantitatively, for data analysis. We explored a method for converting impedance values to elastic modulus (Pa), a coefficient expressing viscosity. Applying this method, we compared changes in the viscosity of the swelling layer in an ArF resist generated during development in a TMAH developing solution and in a TBAH developing solution. This paper reports the results of this comparative study.
High-acoustic-impedance tantalum oxide layers for insulating acoustic reflectors.
Capilla, Jose; Olivares, Jimena; Clement, Marta; Sangrador, Jesús; Iborra, Enrique; Devos, Arnaud
2012-03-01
This work describes the assessment of the acoustic properties of sputtered tantalum oxide films intended for use as high-impedance films of acoustic reflectors for solidly mounted resonators operating in the gigahertz frequency range. The films are grown by sputtering a metallic tantalum target under different oxygen and argon gas mixtures, total pressures, pulsed dc powers, and substrate biases. The structural properties of the films are assessed through infrared absorption spectroscopy and X-ray diffraction measurements. Their acoustic impedance is assessed by deriving the mass density from X-ray reflectometry measurements and the acoustic velocity from picosecond acoustic spectroscopy and the analysis of the frequency response of the test resonators.
On the long range propagation of sound over irregular terrain
NASA Technical Reports Server (NTRS)
Howe, M. S.
1984-01-01
The theory of sound propagation over randomly irregular, nominally plane terrain of finite impedance is discussed. The analysis is an extension of the theory of coherent scatter originally proposed by Biot for an irregular rigid surface. It combines Biot's approach, wherein the surface irregularities are modeled by a homogeneous distribution of hemispherical bosses, with more conventional analyses in which the ground is modeled as a smooth plane of finite impedance. At sufficiently low frequencies the interaction of the surface irregularities with the nearfield of a ground-based source leads to the production of surface waves, which are effective in penetrating the ground shadow zone predicted for a smooth surface of the same impedance.
Sputtered SiO2 as low acoustic impedance material for Bragg mirror fabrication in BAW resonators.
Olivares, Jimena; Wegmann, Enrique; Capilla, José; Iborra, Enrique; Clement, Marta; Vergara, Lucía; Aigner, Robert
2010-01-01
In this paper we describe the procedure to sputter low acoustic impedance SiO(2) films to be used as a low acoustic impedance layer in Bragg mirrors for BAW resonators. The composition and structure of the material are assessed through infrared absorption spectroscopy. The acoustic properties of the films (mass density and sound velocity) are assessed through X-ray reflectometry and picosecond acoustic spectroscopy. A second measurement of the sound velocity is achieved through the analysis of the longitudinal lambda/2 resonance that appears in these silicon oxide films when used as uppermost layer of an acoustic reflector placed under an AlN-based resonator.
Lee, Mi-Ri; Na, Seong-Hun; Park, Hwa-Sun; Suh, Su-Jeong
2014-12-01
The effect of thiourea on the electrochemical nucleation of tin on a copper substrate from a sulfate bath was studied using voltammetry, chronoamperometry, electrochemical impedance spectroscopy, and scanning electron microscopy. Without thiourea, electrodeposition of tin showed very poor surface coverage. However, re-nucleation and growth of tin occurred after the addition of thiourea. In particular, very rapid re-nucleation and growth behavior of tin were observed when up to 6 g/L of thiourea was added. Furthermore, impedance analysis allowed the estimation of the change in the growth behavior of tin when up to 6 g/L of thiourea was added.
Eddy current inspection of weld defects in tubing
NASA Technical Reports Server (NTRS)
Katragadda, G.; Lord, W.
1992-01-01
An approach using differential probes for the inspection of weld defects in tubing is studied. Finite element analysis is used to model the weld regions and defects. Impedance plane signals are predicted for different weld defect types and compared wherever possible with signals from actual welds in tubing. Results show that detection and sizing of defects in tubing is possible using differential eddy current techniques. The phase angle of the impedance plane trajectory gives a good indication of the sizing of the crack. Data on the type of defect can be obtained from the shape of the impedance plane trajectory and the phase. Depending on the skin depth, detection of outer wall, inner wall, and subsurface defects is possible.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stupakov, Gennady; Zhou, Demin
2016-04-21
We develop a general model of coherent synchrotron radiation (CSR) impedance with shielding provided by two parallel conducting plates. This model allows us to easily reproduce all previously known analytical CSR wakes and to expand the analysis to situations not explored before. It reduces calculations of the impedance to taking integrals along the trajectory of the beam. New analytical results are derived for the radiation impedance with shielding for the following orbits: a kink, a bending magnet, a wiggler of finite length, and an infinitely long wiggler. Furthermore, all our formulas are benchmarked against numerical simulations with the CSRZ computermore » code.« less
The practical operational-amplifier gyrator circuit for inductorless filter synthesis
NASA Technical Reports Server (NTRS)
Sutherland, W. C.
1976-01-01
A literature is reported for gyrator circuits utilizing operational amplifiers as the active device. A gyrator is a two port nonreciprocal device with the property that the input impedance is proportional to the reciprocal of the load impedance. Following an experimental study, the gyrator circuit with optimum properties was selected for additional testing. A theoretical analysis was performed and compared to the experimental results for excellent agreement.
Developing a stability assessment method for power electronics-based microgrids
NASA Astrophysics Data System (ADS)
Austin, Peter M.
Modern microgrids with microsources and energy storage are dependent on power electronics for control and regulation. Under certain circumstances power electronics can be destabilizing to the system due to an effect called negative incremental impedance. A careful review of the theory and literature on the subject is presented. This includes stability criteria for both AC and DC systems, as well as a discussion on the limitations posed by the analysis. A method to integrate stability assessment with higher-level microgrid architectural design is proposed. Crucial to this is impedance characterization of individual components, which was accomplished through simulation. DC and AC impedance measurement blocks were created in Matlab simulink to automate the process. A detailed switching-level model of a DC microgrid was implemented in simulink, including wind turbine microsource, battery storage, and three phase inverter. Maximum power point tracking (MPPT) was included to maximize the efficiency of the turbine and was implemented through three rectifier alternatives and control schemes. The stability characteristics of each was compared in the final analysis. Impedance data was collected individually from the components and used to assess stability in the system as a whole. The results included the assessment of stability, margin, and unstable operating points to demonstrate the feasibility of the proposed approach.
A multi-frequency impedance analysing instrument for eddy current testing
NASA Astrophysics Data System (ADS)
Yin, W.; Dickinson, S. J.; Peyton, A. J.
2006-02-01
This paper presents the design of a high-performance multi-frequency impedance analysing instrument (MFIA) for eddy current testing which has been developed primarily for monitoring a steel production process using an inductive sensor. The system consists of a flexible multi-frequency waveform generator and a voltage/current measurement unit. The impedance of the sensor is obtained by cross-spectral analysis of the current and voltage signals. The system contains high-speed digital-to-analogue, analogue-to-digital converters and dual DSPs with one for control and interface and one dedicated to frequency-spectra analysis using fast Fourier transformation (FFT). The frequency span of the signal that can be analysed ranges from 1 kHz to 8 MHz. The system also employs a high-speed serial port interface (USB) to communicate with a personal computer (PC) and to allow for fast transmission of data and control commands. Overall, the system is capable of delivering over 250 impedance spectra per second. Although the instrument has been developed mainly for use with an inductive sensor, the system is not restricted to inductive measurement. The flexibility of the design architecture is demonstrated with capacitive and resistive measurements by using appropriate input circuitry. Issues relating to optimizing the phase of the spectra components in the excitation waveform are also discussed.
NASA Astrophysics Data System (ADS)
Li, Xishuang; Liu, Baohua; Liu, Lejun; Zheng, Jiewen; Zhou, Songwang; Zhou, Qingjie
2017-12-01
The Liwan (Lw) gas field located in the northern slope of the South China Sea (SCS) is extremely complex for its sea-floor topograghy, which is a huge challenge for the safety of subsea facilities. It is economically impractical to obtain parameters for risk assessment of slope stability through a large amount of sampling over the whole field. The linkage between soil shear strength and seabed peak amplitude derived from 2D/3D seismic data is helpful for understanding the regional slope-instability risk. In this paper, the relationships among seabed peak, acoustic impedance and shear strength of shallow soil in the study area were discussed based on statistical analysis results. We obtained a similar relationship to that obtained in other deep-water areas. There is a positive correlation between seabed peak amplitude and acoustic impedance and an exponential relationship between acoustic impedance and shear strength of sediment. The acoustic impedance is the key factor linking the seismic amplitude and shear strength. Infinite slope stability analysis results indicate the areas have a high potential of shallow landslide on slopes exceeding 15° when the thickness of loose sediments exceeds 8 m in the Lw gas field. Our prediction shows that they are mainly located in the heads and walls of submarine canyons.
Aksoy, Emre; Weiss, Brian L.; Zhao, Xin; Awuoche, Erick O.; Wu, Yineng; Aksoy, Serap
2018-01-01
Arthropod vectors have multiple physical and immunological barriers that impede the development and transmission of parasites to new vertebrate hosts. These barriers include the peritrophic matrix (PM), a chitinous barrier that separates the blood bolus from the midgut epithelia and modulates vector-pathogens interactions. In tsetse flies, a sleeve-like PM is continuously produced by the cardia organ located at the fore- and midgut junction. African trypanosomes, Trypanosoma brucei, must bypass the PM twice; first to colonize the midgut and secondly to reach the salivary glands (SG), to complete their transmission cycle in tsetse. However, not all flies with midgut infections develop mammalian transmissible SG infections—the reasons for which are unclear. Here, we used transcriptomics, microscopy and functional genomics analyses to understand the factors that regulate parasite migration from midgut to SG. In flies with midgut infections only, parasites fail to cross the PM as they are eliminated from the cardia by reactive oxygen intermediates (ROIs)—albeit at the expense of collateral cytotoxic damage to the cardia. In flies with midgut and SG infections, expression of genes encoding components of the PM is reduced in the cardia, and structural integrity of the PM barrier is compromised. Under these circumstances trypanosomes traverse through the newly secreted and compromised PM. The process of PM attrition that enables the parasites to re-enter into the midgut lumen is apparently mediated by components of the parasites residing in the cardia. Thus, a fine-tuned dialogue between tsetse and trypanosomes at the cardia determines the outcome of PM integrity and trypanosome transmission success. PMID:29614112
Impedance microflow cytometry for viability studies of microorganisms
NASA Astrophysics Data System (ADS)
Di Berardino, Marco; Hebeisen, Monika; Hessler, Thomas; Ziswiler, Adrian; Largiadèr, Stephanie; Schade, Grit
2011-02-01
Impedance-based Coulter counters and its derivatives are widely used cell analysis tools in many laboratories and use normally DC or low frequency AC to perform these electrical analyses. The emergence of micro-fabrication technologies in the last decade, however, provides a new means of measuring electrical properties of cells. Microfluidic approaches combined with impedance spectroscopy measurements in the radio frequency (RF) range increase sensitivity and information content and thus push single cell analyses beyond simple cell counting and sizing applications towards multiparametric cell characterization. Promising results have been shown already in the fields of cell differentiation and blood analysis. Here we emphasize the potential of this technology by presenting new data obtained from viability studies on microorganisms. Impedance measurements of several yeast and bacteria strains performed at frequencies around 10 MHz enable an easy discrimination between dead and viable cells. Moreover, cytotoxic effects of antibiotics and other reagents, as well as cell starvation can also be monitored easily. Control analyses performed with conventional flow cytometers using various fluorescent dyes (propidium iodide, oxonol) indicate a good correlation and further highlight the capability of this device. The label-free approach makes on the one hand the use of usually expensive fluorochromes obsolete, on the other hand practically eliminates laborious sample preparation procedures. Until now, online cell monitoring was limited to the determination of viable biomass, which provides rather poor information of a cell culture. Impedance microflow cytometry, besides other aspects, proposes a simple solution to these limitations and might become an important tool for bioprocess monitoring applications in the biotech industry.
Nishii, Nobuhiro; Miyoshi, Akihito; Kubo, Motoki; Miyamoto, Masakazu; Morimoto, Yoshimasa; Kawada, Satoshi; Nakagawa, Koji; Watanabe, Atsuyuki; Nakamura, Kazufumi; Morita, Hiroshi; Ito, Hiroshi
2018-03-01
Remote monitoring (RM) has been advocated as the new standard of care for patients with cardiovascular implantable electronic devices (CIEDs). RM has allowed the early detection of adverse clinical events, such as arrhythmia, lead failure, and battery depletion. However, lead failure was often identified only by arrhythmic events, but not impedance abnormalities. To compare the usefulness of arrhythmic events with conventional impedance abnormalities for identifying lead failure in CIED patients followed by RM. CIED patients in 12 hospitals have been followed by the RM center in Okayama University Hospital. All transmitted data have been analyzed and summarized. From April 2009 to March 2016, 1,873 patients have been followed by the RM center. During the mean follow-up period of 775 days, 42 lead failure events (atrial lead 22, right ventricular pacemaker lead 5, implantable cardioverter defibrillator [ICD] lead 15) were detected. The proportion of lead failures detected only by arrhythmic events, which were not detected by conventional impedance abnormalities, was significantly higher than that detected by impedance abnormalities (arrhythmic event 76.2%, 95% CI: 60.5-87.9%; impedance abnormalities 23.8%, 95% CI: 12.1-39.5%). Twenty-seven events (64.7%) were detected without any alert. Of 15 patients with ICD lead failure, none has experienced inappropriate therapy. RM can detect lead failure earlier, before clinical adverse events. However, CIEDs often diagnose lead failure as just arrhythmic events without any warning. Thus, to detect lead failure earlier, careful human analysis of arrhythmic events is useful. © 2017 Wiley Periodicals, Inc.
Gudra, Tadeusz; Opieliński, Krzysztof J
2002-05-01
In different solutions of ultrasonic transducers radiating acoustic energy into the air there occurs the problem of the proper selection of the acoustic impedance of one or more matching layers. The goal of this work was a computer analysis of the influence of acoustic impedance on the transfer function of piezoceramic transducers equipped with matching layers. Cases of resonance and non-resonance matching impedance in relation to the transfer function and the energy transmission coefficient for solid state-air systems were analysed. With stable thickness of matching layers the required shape of the transfer function can be obtained through proper choice of acoustic impedance were built (e.g. maximal flat function). The proper choice of acoustic impedance requires an elaboration of precise methods of synthesis of matching systems. Using the known matching criteria (Chebyshev's, DeSilets', Souquet's), the transfer function characteristics of transducers equipped with one, two, and three matching layers as well as the optimisation methods of the energy transmission coefficient were presented. The influence of the backside load of the transducer on the shape of transfer function was also analysed. The calculation results of this function for different loads of the transducer backside without and with the different matching layers were presented. The proper load selection allows us to obtain the desired shape of the transfer function, which determines the pulse shape generated by the transducer.
Discriminating movements of liquid and gas in the rabbit colon with impedance manometry.
Mohd Rosli, R; Leibbrandt, R E; Wiklendt, L; Costa, M; Wattchow, D A; Spencer, N J; Brookes, S J; Omari, T I; Dinning, P G
2018-05-01
High-resolution impedance manometry is a technique that is well established in esophageal motility studies for relating motor patterns to bolus flow. The use of this technique in the colon has not been established. In isolated segments of rabbit proximal colon, we recorded motor patterns and the movement of liquid or gas boluses with a high-resolution impedance manometry catheter. These detected movements were compared to video recorded changes in gut diameter. Using the characteristic shapes of the admittance (inverse of impedance) and pressure signals associated with gas or liquid flow we developed a computational algorithm for the automated detection of these events. Propagating contractions detected by video were also recorded by manometry and impedance. Neither pressure nor admittance signals alone could distinguish between liquid and gas transit, however the precise relationship between admittance and pressure signals during bolus flow could. Training our computational algorithm upon these characteristic shapes yielded a detection accuracy of 87.7% when compared to gas or liquid bolus events detected by manual analysis. Characterizing the relationship between both admittance and pressure recorded with high-resolution impedance manometry can not only help in detecting luminal transit in real time, but also distinguishes between liquid and gaseous content. This technique holds promise for determining the propulsive nature of human colonic motor patterns. © 2017 John Wiley & Sons Ltd.
Hu, Shi-Jie; Li, Xia; Xu, Can-Hua; Wang, Bing; Yang, Bin; Tang, Meng-Xing; Dong, Xiu-Zhen; Fei, Zhou; Shi, Xue-Tao
2014-01-01
Objective Variations of conductive fluid content in brain tissue (e.g. cerebral edema) change tissue impedance and can potentially be measured by Electrical Impedance Tomography (EIT), an emerging medical imaging technique. The objective of this work is to establish the feasibility of using EIT as an imaging tool for monitoring brain fluid content. Design a prospective study. Setting In this study EIT was used, for the first time, to monitor variations in cerebral fluid content in a clinical model with patients undergoing clinical dehydration treatment. The EIT system was developed in house and its imaging sensitivity and spatial resolution were evaluated on a saline-filled tank. Patients 23 patients with brain edema. Interventions The patients were continuously imaged by EIT for two hours after initiation of dehydration treatment using 0.5 g/kg intravenous infusion of mannitol for 20 minutes. Measurement and Main Results Overall impedance across the brain increased significantly before and after mannitol dehydration treatment (p = 0.0027). Of the all 23 patients, 14 showed high-level impedance increase and maintained this around 4 hours after the dehydration treatment whereas the other 9 also showed great impedance gain during the treatment but it gradually decreased after the treatment. Further analysis of the regions of interest in the EIT images revealed that diseased regions, identified on corresponding CT images, showed significantly less impedance changes than normal regions during the monitoring period, indicating variations in different patients' responses to such treatment. Conclusions EIT shows potential promise as an imaging tool for real-time and non-invasive monitoring of brain edema patients. PMID:25474474
Design of current source for multi-frequency simultaneous electrical impedance tomography
NASA Astrophysics Data System (ADS)
Han, Bing; Xu, Yanbin; Dong, Feng
2017-09-01
Multi-frequency electrical impedance tomography has been evolving from the frequency-sweep approach to the multi-frequency simultaneous measurement technique which can reduce measuring time and will be increasingly attractive for time-varying biological applications. The accuracy and stability of the current source are the key factors determining the quality of the image reconstruction. This article presents a field programmable gate array-based current source for a multi-frequency simultaneous electrical impedance tomography system. A novel current source circuit was realized by combining the classic current mirror based on the feedback amplifier AD844 with a differential topology. The optimal phase offsets of harmonic sinusoids were obtained through the crest factor analysis. The output characteristics of this current source were evaluated by simulation and actual measurement. The results include the following: (1) the output impedance was compared with one of the Howland pump circuit in simulation, showing comparable performance at low frequencies. However, the proposed current source makes lower demands for resistor tolerance but performs even better at high frequencies. (2) The output impedance in actual measurement below 200 kHz is above 1.3 MΩ and can reach 250 KΩ up to 1 MHz. (3) An experiment based on a biological RC model has been implemented. The mean error for the demodulated impedance amplitude and phase are 0.192% and 0.139°, respectively. Therefore, the proposed current source is wideband, biocompatible, and high precision, which demonstrates great potential to work as a sub-system in the multi-frequency electrical impedance tomography system.
NASA Technical Reports Server (NTRS)
Bielawa, R. L.
1984-01-01
The mathematical development for the expanded capabilities of the G400 rotor aeroelastic analysis was examined. The G400PA expanded analysis simulates the dynamics of all conventional rotors, blade pendulum vibration absorbers, and the higher harmonic excitations resulting from prescribed vibratory hub motions and higher harmonic blade pitch control. The methodology for modeling the unsteady stalled airloads of two dimensional airfoils is discussed. Formulations for calculating the rotor impedance matrix appropriate to the higher harmonic blade excitations are outlined. This impedance matrix, and the associated vibratory hub loads, are the rotor dynamic characteristic elements for use in the simplified coupled rotor/fuselage vibration analysis (SIMVIB). Updates to the development of the original G400 theory, program documentation, user instructions and information are presented.
Everson, Elizabeth M; Hocum, Jonah D; Trobridge, Grant D
2018-06-23
Previous studies have shown that foamy viral (FV) vectors are a promising alternative to gammaretroviral and lentiviral vectors and insulators can improve FV vector safety. However, in a previous analysis of insulator effects on FV vector safety, strong viral promoters were used to elicit genotoxic events. Here we developed and analyzed the efficacy and safety of a high-titer, clinically relevant FV vector driven by the housekeeping promoter elongation factor-1α and insulated with an enhancer blocking A1 insulator (FV-EGW-A1). Human CD34 + cord blood cells were exposed to an enhanced green fluorescent protein expressing vector, FV-EGW-A1, at a multiplicity of infection of 10 and then maintained in vitro or transplanted into immunodeficient mice. Flow cytometry was used to measure engraftment and marking in vivo. FV vector integration sites were analyzed to assess safety. FV-EGW-A1 resulted in high-marking, multi-lineage engraftment of human repopulating cells with no evidence of silencing. Engraftment was highly polyclonal with no clonal dominance and a promising safety profile based on integration site analysis. An FV vector with an elongation factor-1α promoter and an A1 insulator is a promising vector design for use in the clinic. This article is protected by copyright. All rights reserved.
The evolution of plant virus transmission pathways.
Hamelin, Frédéric M; Allen, Linda J S; Prendeville, Holly R; Hajimorad, M Reza; Jeger, Michael J
2016-05-07
The evolution of plant virus transmission pathways is studied through transmission via seed, pollen, or a vector. We address the questions: under what circumstances does vector transmission make pollen transmission redundant? Can evolution lead to the coexistence of multiple virus transmission pathways? We restrict the analysis to an annual plant population in which reproduction through seed is obligatory. A semi-discrete model with pollen, seed, and vector transmission is formulated to investigate these questions. We assume vector and pollen transmission rates are frequency-dependent and density-dependent, respectively. An ecological stability analysis is performed for the semi-discrete model and used to inform an evolutionary study of trade-offs between pollen and seed versus vector transmission. Evolutionary dynamics critically depend on the shape of the trade-off functions. Assuming a trade-off between pollen and vector transmission, evolution either leads to an evolutionarily stable mix of pollen and vector transmission (concave trade-off) or there is evolutionary bi-stability (convex trade-off); the presence of pollen transmission may prevent evolution of vector transmission. Considering a trade-off between seed and vector transmission, evolutionary branching and the subsequent coexistence of pollen-borne and vector-borne strains is possible. This study contributes to the theory behind the diversity of plant-virus transmission patterns observed in nature. Copyright © 2016 Elsevier Ltd. All rights reserved.
Structural Analysis of Biodiversity
Sirovich, Lawrence; Stoeckle, Mark Y.; Zhang, Yu
2010-01-01
Large, recently-available genomic databases cover a wide range of life forms, suggesting opportunity for insights into genetic structure of biodiversity. In this study we refine our recently-described technique using indicator vectors to analyze and visualize nucleotide sequences. The indicator vector approach generates correlation matrices, dubbed Klee diagrams, which represent a novel way of assembling and viewing large genomic datasets. To explore its potential utility, here we apply the improved algorithm to a collection of almost 17000 DNA barcode sequences covering 12 widely-separated animal taxa, demonstrating that indicator vectors for classification gave correct assignment in all 11000 test cases. Indicator vector analysis revealed discontinuities corresponding to species- and higher-level taxonomic divisions, suggesting an efficient approach to classification of organisms from poorly-studied groups. As compared to standard distance metrics, indicator vectors preserve diagnostic character probabilities, enable automated classification of test sequences, and generate high-information density single-page displays. These results support application of indicator vectors for comparative analysis of large nucleotide data sets and raise prospect of gaining insight into broad-scale patterns in the genetic structure of biodiversity. PMID:20195371
Sensorless battery temperature measurements based on electrochemical impedance spectroscopy
NASA Astrophysics Data System (ADS)
Raijmakers, L. H. J.; Danilov, D. L.; van Lammeren, J. P. M.; Lammers, M. J. G.; Notten, P. H. L.
2014-02-01
A new method is proposed to measure the internal temperature of (Li-ion) batteries. Based on electrochemical impedance spectroscopy measurements, an intercept frequency (f0) can be determined which is exclusively related to the internal battery temperature. The intercept frequency is defined as the frequency at which the imaginary part of the impedance is zero (Zim = 0), i.e. where the phase shift between the battery current and voltage is absent. The advantage of the proposed method is twofold: (i) no hardware temperature sensors are required anymore to monitor the battery temperature and (ii) the method does not suffer from heat transfer delays. Mathematical analysis of the equivalent electrical-circuit, representing the battery performance, confirms that the intercept frequency decreases with rising temperatures. Impedance measurements on rechargeable Li-ion cells of various chemistries were conducted to verify the proposed method. These experiments reveal that the intercept frequency is clearly dependent on the temperature and does not depend on State-of-Charge (SoC) and aging. These impedance-based sensorless temperature measurements are therefore simple and convenient for application in a wide range of stationary, mobile and high-power devices, such as hybrid- and full electric vehicles.
Non-Contact EDDY Current Hole Eccentricity and Diameter Measurement
NASA Technical Reports Server (NTRS)
Chern, E. James
1998-01-01
Precision holes are among the most critical features of a mechanical component. Deviations from permissible tolerances can impede operation and result in unexpected failure. We have developed an automated non-contact eddy current hole diameter and eccentricity measuring system. The operating principle is based on the eddy current lift-off effect, which is the coil impedance as a function of the distance between the coil and the test object. An absolute eddy current probe rotates in the hole. The impedance of each angular position is acquired and input to the computer for integration and analysis. The eccentricity of the hole is the profile of the impedance as a function of angular position as compared to a straight line, an ideal hole. The diameter of the hole is the sum of the diameter of the probe and twice the distance-calibrated impedance. An eddy current image is generated by integrating angular scans for a plurality of depths between the top and bottom to display the eccentricity profile. This system can also detect and image defects in the hole. The method for non-contact eddy current hole diameter and eccentricity measurement has been granted a patent by the U.S. Patent and Trademark Office.
NASA Astrophysics Data System (ADS)
Chang, Fu-Yu; Chen, Ming-Kun; Wang, Min-Haw; Jang, Ling-Sheng
2016-02-01
Cell impedance analysis is widely used for monitoring biological and medical reactions. In this study, a highly sensitive three-dimensional (3D) interdigitated microelectrode (IME) with a high aspect ratio on a polyimide (PI) flexible substrate was fabricated for microparticle detection (e.g. cell quantity detection) using electroforming and lithography technology. 3D finite element simulations were performed to compare the performance of the 3D IME (in terms of sensitivity and signal-to-noise ratio) to that of a planar IME for particles in the sensing area. Various quantities of particles were captured in Dulbecco’s modified Eagle medium and their impedances were measured. With the 3D IME, the particles were arranged in the gap, not on the electrode, avoiding the noise due to particle position. For the maximum particle quantities, the results show that the 3D IME has at least 5-fold higher sensitivity than that of the planar IME. The trends of impedance magnitude and phase due to particle quantity were verified using the equivalent circuit model. The impedance (1269 Ω) of 69 particles was used to estimate the particle quantity (68 particles) with 98.6% accuracy using a parabolic regression curve at 500 kHz.
Grimaldi, E; Del Vecchio, L; Scopacasa, F; Lo Pardo, C; Capone, F; Pariante, S; Scalia, G; De Caterina, M
2009-04-01
The Abbot Cell-Dyn Sapphire is a new generation haematology analyser. The system uses optical/fluorescence flow cytometry in combination with electronic impedance to produce a full blood count. Optical and impedance are the default methods for platelet counting while automated CD61-immunoplatelet analysis can be run as selectable test. The aim of this study was to determine the platelet count performance of the three counting methods available on the instrument and to compare the results with those provided by Becton Dickinson FACSCalibur flow cytometer used as reference method. A lipid interference experiment was also performed. Linearity, carryover and precision were good, and satisfactory agreement with reference method was found for the impedance, optical and CD61-immunoplatelet analysis, although this latter provided the closest results in comparison with flow cytometry. In the lipid interference experiment, a moderate inaccuracy of optical and immunoplatelet counts was observed starting from a very high lipid value.
Zhang, Hai-Long; Fu, Qiang; Li, Wen-Hui; Liu, Su-Wei; Zhong, Hua; Duoji, Bai-Ma; Zhang, Mei-Zhi; Lv, Po; Xi, Huan-Jiu
2015-01-01
We aimed to obtain the fat base value and the fat distribution characteristics of Tibetan children and teenagers by estimating their body fat content with the bioelectrical impedance method. We recruited 1427 healthy children and teenagers by a stratified cluster sampling method. By using bioelectrical impedance analysis, we obtained various values relevant to fat. We found that total body fat mass and the fat mass of various body parts increased with age in boys and girls. Yet there were no differences between age groups until 11 years. However, fat mass increased quickly between 11 and 18 years, and significant differences were seen between adolescent boys and girls; all fat indices were higher in girls than in boys (p<0.05). The characteristics of fat in Tibetan children and teenagers in Tibet is related to age and gender related hormone secretion, which reflects the physiological characteristics in different developmental stages.
NASA Technical Reports Server (NTRS)
Ricks, R. C. (Compiler); Lushbaugh, C. C. (Compiler)
1975-01-01
The radiobiologic studies carried out with joint (AEC) ERDA and NASA support during the years 1964 to 1974 at the Medical Division of Oak Ridge Associated Universities are presented. The physiologic data generated were similar in many ways to those previously observed in other medical radiobiologic experiences. They differed, however, in the methods of data acquisition and analysis. Instead of more conventional analytical methods, pulmonary impedance was recorded and quantitated as a measure of radiation-induced gastrointestinal distress and fatiguability. While refinements in dose response related to gastrointestinal distress were accomplished, it was also found that through the use of Fourier analysis of pulmonary impedance waveform GI distress could easily be recognized and quantified even when the initial stages of nausea were below the subjects subjective level of recognition. The results demonstrate that change in pulmonary impedance waveform closely parallel well-defined stages of GI distress, i.e., initial nausea, a progressive increase in nausea, and finally vomiting episodes.
Ehsani, A; Mahjani, M G; Hosseini, M; Safari, R; Moshrefi, R; Mohammad Shiri, H
2017-03-15
Inhibition performance of Thymus vulgaris plant leaves extract (thyme) as environmentally friendly (green) inhibitor for the corrosion protection of stainless steel (SS) type 304 in 1.0molL -1 HCl solution was studied by potentiodynamic polarization, electrochemical impedance (EIS) and electrochemical noise measurements (EN) techniques. The EN data were analyzed with FFT technique to make the spectral power density plots. The calculations were performed by MATLAB 2014a software. Geometry optimization and calculation of the structural and electronic properties of the molecular system of inhibitor have been carried out using UB3LYP/6-311++G ∗∗ level. Moreover, the results obtained from electrochemical noise analysis were compared with potentiodynamic polarization and electrochemical impedance spectroscopy. All of the used techniques showed positive effect of green inhibitor with increasing inhibitor concentration. Copyright © 2016 Elsevier Inc. All rights reserved.
Preventing malaria in the Peruvian Amazon: a qualitative study in Iquitos, Peru.
Newell, Ian; Wiskin, Connie; Anthoney, James; Meza, Graciela; de Wildt, Gilles
2018-01-16
In Peru, despite decades of concerted control efforts, malaria remains a significant public health burden. Peru has recently exhibited a dramatic rise in malaria incidence, impeding South America's progress towards malaria elimination. The Amazon basin, in particular the Loreto region of Peru, has been identified as a target for the implementation of intensified control strategies, aiming for elimination. No research has addressed why vector control strategies in Loreto have had limited impact in the past, despite vector control elsewhere being highly effective in reducing malaria transmission. This study employed qualitative methods to explore factors limiting the success of vector control strategies in the region. Twenty semi-structured interviews were conducted among adults attending a primary care centre in Iquitos, Peru, together with 3 interviews with key informants (health care professionals). The interviews focussed on how local knowledge, together with social and cultural attitudes, determined the use of vector control methods. Five themes emerged. (a) Participants believed malaria to be embedded within their culture, and commonly blamed this for a lack of regard for prevention. (b) They perceived a shift in mosquito biting times to early evening, rendering night-time use of bed nets less effective. (c) Poor preventive practices were compounded by a consensus that malaria prevention was the government's responsibility, and that this reduced motivation for personal prevention. (d) Participants confused the purpose of space-spraying. (e) Participants' responses also exposed persisting misconceptions, mainly concerning the cause of malaria and best practices for its prevention. To eliminate malaria from the Americas, region-specific strategies need to be developed that take into account the local social and cultural contexts. In Loreto, further research is needed to explore the potential shift in biting behaviour of Anopheles darlingi, and how this interacts with the population's social behaviours and current use of preventive measures. Attitudes concerning personal responsibility for malaria prevention and long-standing misconceptions as to the cause of malaria and best preventive practices also need to be addressed.
Reference geometry-based detection of (4D-)CT motion artifacts: a feasibility study
NASA Astrophysics Data System (ADS)
Werner, René; Gauer, Tobias
2015-03-01
Respiration-correlated computed tomography (4D or 3D+t CT) can be considered as standard of care in radiation therapy treatment planning for lung and liver lesions. The decision about an application of motion management devices and the estimation of patient-specific motion effects on the dose distribution relies on precise motion assessment in the planning 4D CT data { which is impeded in case of CT motion artifacts. The development of image-based/post-processing approaches to reduce motion artifacts would benefit from precise detection and localization of the artifacts. Simple slice-by-slice comparison of intensity values and threshold-based analysis of related metrics suffer from- depending on the threshold- high false-positive or -negative rates. In this work, we propose exploiting prior knowledge about `ideal' (= artifact free) reference geometries to stabilize metric-based artifact detection by transferring (multi-)atlas-based concepts to this specific task. Two variants are introduced and evaluated: (S1) analysis and comparison of warped atlas data obtained by repeated non-linear atlas-to-patient registration with different levels of regularization; (S2) direct analysis of vector field properties (divergence, curl magnitude) of the atlas-to-patient transformation. Feasibility of approaches (S1) and (S2) is evaluated by motion-phantom data and intra-subject experiments (four patients) as well as - adopting a multi-atlas strategy- inter-subject investigations (twelve patients involved). It is demonstrated that especially sorting/double structure artifacts can be precisely detected and localized by (S1). In contrast, (S2) suffers from high false positive rates.
Definition of Contravariant Velocity Components
NASA Technical Reports Server (NTRS)
Hung, Ching-moa; Kwak, Dochan (Technical Monitor)
2002-01-01
In this paper we have reviewed the basics of tensor analysis in an attempt to clarify some misconceptions regarding contravariant and covariant vector components as used in fluid dynamics. We have indicated that contravariant components are components of a given vector expressed as a unique combination of the covariant base vector system and, vice versa, that the covariant components are components of a vector expressed with the contravariant base vector system. Mathematically, expressing a vector with a combination of base vector is a decomposition process for a specific base vector system. Hence, the contravariant velocity components are decomposed components of velocity vector along the directions of coordinate lines, with respect to the covariant base vector system. However, the contravariant (and covariant) components are not physical quantities. Their magnitudes and dimensions are controlled by their corresponding covariant (and contravariant) base vectors.
Method for predicting peptide detection in mass spectrometry
Kangas, Lars [West Richland, WA; Smith, Richard D [Richland, WA; Petritis, Konstantinos [Richland, WA
2010-07-13
A method of predicting whether a peptide present in a biological sample will be detected by analysis with a mass spectrometer. The method uses at least one mass spectrometer to perform repeated analysis of a sample containing peptides from proteins with known amino acids. The method then generates a data set of peptides identified as contained within the sample by the repeated analysis. The method then calculates the probability that a specific peptide in the data set was detected in the repeated analysis. The method then creates a plurality of vectors, where each vector has a plurality of dimensions, and each dimension represents a property of one or more of the amino acids present in each peptide and adjacent peptides in the data set. Using these vectors, the method then generates an algorithm from the plurality of vectors and the calculated probabilities that specific peptides in the data set were detected in the repeated analysis. The algorithm is thus capable of calculating the probability that a hypothetical peptide represented as a vector will be detected by a mass spectrometry based proteomic platform, given that the peptide is present in a sample introduced into a mass spectrometer.
Zeier, Zane; Aguilar, J Santiago; Lopez, Cecilia M; Devi-Rao, G B; Watson, Zachary L; Baker, Henry V; Wagner, Edward K; Bloom, David C
2010-01-01
Herpes simplex virus type 1 (HSV-1)–based vectors readily transduce neurons and have a large payload capacity, making them particularly amenable to gene therapy applications within the central nervous system (CNS). Because aspects of the host responses to HSV-1 vectors in the CNS are largely unknown, we compared the host response of a nonreplicating HSV-1 vector to that of a replication-competent HSV-1 virus using microarray analysis. In parallel, HSV-1 gene expression was tracked using HSV-specific oligonucleotide-based arrays in order to correlate viral gene expression with observed changes in host response. Microarray analysis was performed following stereotactic injection into the right hippocampal formation of mice with either a replication-competent HSV-1 or a nonreplicating recombinant of HSV-1, lacking the ICP4 gene (ICP4−). Genes that demonstrated a significant change (P < .001) in expression in response to the replicating HSV-1 outnumbered those that changed in response to mock or nonreplicating vector by approximately 3-fold. Pathway analysis revealed that both the replicating and nonreplicating vectors induced robust antigen presentation but only mild interferon, chemokine, and cytokine signaling responses. The ICP4− vector was restricted in several of the Toll-like receptor-signaling pathways, indicating reduced stimulation of the innate immune response. These array analyses suggest that although the nonreplicating vector induces detectable activation of immune response pathways, the number and magnitude of the induced response is dramatically restricted compared to the replicating vector, and with the exception of antigen presentation, host gene expression induced by the non-replicating vector largely resembles mock infection. PMID:20095947
INTERIM ANALYSIS OF THE CONTRIBUTION OF HIGH-LEVEL EVIDENCE FOR DENGUE VECTOR CONTROL.
Horstick, Olaf; Ranzinger, Silvia Runge
2015-01-01
This interim analysis reviews the available systematic literature for dengue vector control on three levels: 1) single and combined vector control methods, with existing work on peridomestic space spraying and on Bacillus thuringiensis israelensis; further work is available soon on the use of Temephos, Copepods and larvivorous fish; 2) or for a specific purpose, like outbreak control, and 3) on a strategic level, as for example decentralization vs centralization, with a systematic review on vector control organization. Clear best practice guidelines for methodology of entomological studies are needed. There is a need to include measuring dengue transmission data. The following recommendations emerge: Although vector control can be effective, implementation remains an issue; Single interventions are probably not useful; Combinations of interventions have mixed results; Careful implementation of vector control measures may be most important; Outbreak interventions are often applied with questionable effectiveness.
Electric dipole radiation at VLF in a uniform warm magneto-plasma.
NASA Technical Reports Server (NTRS)
Wang, T. N. C.; Bell, T. F.
1972-01-01
Use of a linear full electromagnetic wave theory to calculate the input impedance of an electric antenna embedded in a uniform, lossless, unbounded warm magnetoplasma, which is assumed to consist of warm electrons and cold ions. In calculating the dipole radiation resistance for the thermal modes and the thermally modified whistler mode the analysis includes the finite temperature only for the electrons. In deriving the formal solution of the warm plasma dipole input impedance a full-wave analysis is used and two antenna orientations are considered, parallel and perpendicular to the static magnetic field. A general dispersion equation governing the modes of propagation is derived and a detailed analysis is made of the propagation characteristics of these modes.
Monteghetti, Florian; Matignon, Denis; Piot, Estelle; Pascal, Lucas
2016-09-01
A methodology to design broadband time-domain impedance boundary conditions (TDIBCs) from the analysis of acoustical models is presented. The derived TDIBCs are recast exclusively as first-order differential equations, well-suited for high-order numerical simulations. Broadband approximations are yielded from an elementary linear least squares optimization that is, for most models, independent of the absorbing material geometry. This methodology relies on a mathematical technique referred to as the oscillatory-diffusive (or poles and cuts) representation, and is applied to a wide range of acoustical models, drawn from duct acoustics and outdoor sound propagation, which covers perforates, semi-infinite ground layers, as well as cavities filled with a porous medium. It is shown that each of these impedance models leads to a different TDIBC. Comparison with existing numerical models, such as multi-pole or extended Helmholtz resonator, provides insights into their suitability. Additionally, the broadly-applicable fractional polynomial impedance models are analyzed using fractional calculus.
Little, Charles A E; Orloff, Nathan D; Hanemann, Isaac E; Long, Christian J; Bright, Victor M; Booth, James C
2017-07-25
Broadband microfluidic-based impedance spectroscopy can be used to characterize complex fluids, with applications in medical diagnostics and in chemical and pharmacological manufacturing. Many relevant fluids are ionic; during impedance measurements ions migrate to the electrodes, forming an electrical double-layer. Effects from the electrical double-layer dominate over, and reduce sensitivity to, the intrinsic impedance of the fluid below a characteristic frequency. Here we use calibrated measurements of saline solution in microfluidic coplanar waveguide devices at frequencies between 100 kHz and 110 GHz to directly measure the double-layer admittance for solutions of varying ionic conductivity. We successfully model the double-layer admittance using a combination of a Cole-Cole response with a constant phase element contribution. Our analysis yields a double-layer relaxation time that decreases linearly with solution conductivity, and allows for double-layer effects to be separated from the intrinsic fluid response and quantified for a wide range of conducting fluids.
Imaging fast electrical activity in the brain with electrical impedance tomography
Aristovich, Kirill Y.; Packham, Brett C.; Koo, Hwan; Santos, Gustavo Sato dos; McEvoy, Andy; Holder, David S.
2016-01-01
Imaging of neuronal depolarization in the brain is a major goal in neuroscience, but no technique currently exists that could image neural activity over milliseconds throughout the whole brain. Electrical impedance tomography (EIT) is an emerging medical imaging technique which can produce tomographic images of impedance changes with non-invasive surface electrodes. We report EIT imaging of impedance changes in rat somatosensory cerebral cortex with a resolution of 2 ms and < 200 μm during evoked potentials using epicortical arrays with 30 electrodes. Images were validated with local field potential recordings and current source-sink density analysis. Our results demonstrate that EIT can image neural activity in a volume 7 × 5 × 2 mm in somatosensory cerebral cortex with reduced invasiveness, greater resolution and imaging volume than other methods. Modeling indicates similar resolutions are feasible throughout the entire brain so this technique, uniquely, has the potential to image functional connectivity of cortical and subcortical structures. PMID:26348559
Bioelectrical impedance analysis of bovine milk fat
NASA Astrophysics Data System (ADS)
Veiga, E. A.; Bertemes-Filho, P.
2012-12-01
Three samples of 250ml at home temperature of 20°C were obtained from whole, low fat and fat free bovine UHT milk. They were analysed by measuring both impedance spectra and dc conductivity in order to establish the relationship between samples related to fat content. An impedance measuring system was developed, which is based on digital oscilloscope, a current source and a FPGA. Data was measured by the oscilloscope in the frequency 1 kHz to 100 kHz. It was showed that there is approximately 7.9% difference in the conductivity between whole and low fat milk whereas 15.9% between low fat and free fat one. The change of fatness in the milk can be significantly sensed by both impedance spectra measurements and dc conductivity. This result might be useful for detecting fat content of milk in a very simple way and also may help the development of sensors for measuring milk quality, as for example the detection of mastitis.
Lin, Tzu-Hsuan; Lu, Yung-Chi; Hung, Shih-Lin
2014-01-01
This study developed an integrated global-local approach for locating damage on building structures. A damage detection approach with a novel embedded frequency response function damage index (NEFDI) was proposed and embedded in the Imote2.NET-based wireless structural health monitoring (SHM) system to locate global damage. Local damage is then identified using an electromechanical impedance- (EMI-) based damage detection method. The electromechanical impedance was measured using a single-chip impedance measurement device which has the advantages of small size, low cost, and portability. The feasibility of the proposed damage detection scheme was studied with reference to a numerical example of a six-storey shear plane frame structure and a small-scale experimental steel frame. Numerical and experimental analysis using the integrated global-local SHM approach reveals that, after NEFDI indicates the approximate location of a damaged area, the EMI-based damage detection approach can then identify the detailed damage location in the structure of the building.
Antenna pattern control using impedance surfaces
NASA Technical Reports Server (NTRS)
Balanis, Constantine A.; Liu, Kefeng
1992-01-01
During this research period, we have effectively transferred existing computer codes from CRAY supercomputer to work station based systems. The work station based version of our code preserved the accuracy of the numerical computations while giving a much better turn-around time than the CRAY supercomputer. Such a task relieved us of the heavy dependence of the supercomputer account budget and made codes developed in this research project more feasible for applications. The analysis of pyramidal horns with impedance surfaces was our major focus during this research period. Three different modeling algorithms in analyzing lossy impedance surfaces were investigated and compared with measured data. Through this investigation, we discovered that a hybrid Fourier transform technique, which uses the eigen mode in the stepped waveguide section and the Fourier transformed field distributions across the stepped discontinuities for lossy impedances coating, gives a better accuracy in analyzing lossy coatings. After a further refinement of the present technique, we will perform an accurate radiation pattern synthesis in the coming reporting period.
Wavelet transformation to determine impedance spectra of lithium-ion rechargeable battery
NASA Astrophysics Data System (ADS)
Hoshi, Yoshinao; Yakabe, Natsuki; Isobe, Koichiro; Saito, Toshiki; Shitanda, Isao; Itagaki, Masayuki
2016-05-01
A new analytical method is proposed to determine the electrochemical impedance of lithium-ion rechargeable batteries (LIRB) from time domain data by wavelet transformation (WT). The WT is a waveform analysis method that can transform data in the time domain to the frequency domain while retaining time information. In this transformation, the frequency domain data are obtained by the convolution integral of a mother wavelet and original time domain data. A complex Morlet mother wavelet (CMMW) is used to obtain the complex number data in the frequency domain. The CMMW is expressed by combining a Gaussian function and sinusoidal term. The theory to select a set of suitable conditions for variables and constants related to the CMMW, i.e., band, scale, and time parameters, is established by determining impedance spectra from wavelet coefficients using input voltage to the equivalent circuit and the output current. The impedance spectrum of LIRB determined by WT agrees well with that measured using a frequency response analyzer.
Visualizing vector field topology in fluid flows
NASA Technical Reports Server (NTRS)
Helman, James L.; Hesselink, Lambertus
1991-01-01
Methods of automating the analysis and display of vector field topology in general and flow topology in particular are discussed. Two-dimensional vector field topology is reviewed as the basis for the examination of topology in three-dimensional separated flows. The use of tangent surfaces and clipping in visualizing vector field topology in fluid flows is addressed.
ERIC Educational Resources Information Center
Kwon, Oh Hoon
2012-01-01
This dissertation documents a new way of conceptualizing vectors in college mathematics, especially in geometry. First, I will introduce three problems to show the complexity and subtlety of the construct of vectors with the classical vector representations. These highlight the need for a new framework that: (1) differentiates abstraction from a…
A unified development of several techniques for the representation of random vectors and data sets
NASA Technical Reports Server (NTRS)
Bundick, W. T.
1973-01-01
Linear vector space theory is used to develop a general representation of a set of data vectors or random vectors by linear combinations of orthonormal vectors such that the mean squared error of the representation is minimized. The orthonormal vectors are shown to be the eigenvectors of an operator. The general representation is applied to several specific problems involving the use of the Karhunen-Loeve expansion, principal component analysis, and empirical orthogonal functions; and the common properties of these representations are developed.
NASA Astrophysics Data System (ADS)
Ansari, Hamid Reza
2014-09-01
In this paper we propose a new method for predicting rock porosity based on a combination of several artificial intelligence systems. The method focuses on one of the Iranian carbonate fields in the Persian Gulf. Because there is strong heterogeneity in carbonate formations, estimation of rock properties experiences more challenge than sandstone. For this purpose, seismic colored inversion (SCI) and a new approach of committee machine are used in order to improve porosity estimation. The study comprises three major steps. First, a series of sample-based attributes is calculated from 3D seismic volume. Acoustic impedance is an important attribute that is obtained by the SCI method in this study. Second, porosity log is predicted from seismic attributes using common intelligent computation systems including: probabilistic neural network (PNN), radial basis function network (RBFN), multi-layer feed forward network (MLFN), ε-support vector regression (ε-SVR) and adaptive neuro-fuzzy inference system (ANFIS). Finally, a power law committee machine (PLCM) is constructed based on imperial competitive algorithm (ICA) to combine the results of all previous predictions in a single solution. This technique is called PLCM-ICA in this paper. The results show that PLCM-ICA model improved the results of neural networks, support vector machine and neuro-fuzzy system.
Increased expression of the WNT antagonist sFRP-1 in glaucoma elevates intraocular pressure
Wang, Wan-Heng; McNatt, Loretta G.; Pang, Iok-Hou; Millar, J. Cameron; Hellberg, Peggy E.; Hellberg, Mark H.; Steely, H. Thomas; Rubin, Jeffrey S.; Fingert, John H.; Sheffield, Val C.; Stone, Edwin M.; Clark, Abbot F.
2008-01-01
Elevated intraocular pressure (IOP) is the principal risk factor for glaucoma and results from excessive impedance of the fluid outflow from the eye. This abnormality likely originates from outflow pathway tissues such as the trabecular meshwork (TM), but the associated molecular etiology is poorly understood. We discovered what we believe to be a novel role for secreted frizzled-related protein-1 (sFRP-1), an antagonist of Wnt signaling, in regulating IOP. sFRP1 was overexpressed in human glaucomatous TM cells. Genes involved in the Wnt signaling pathway were expressed in cultured TM cells and human TM tissues. Addition of recombinant sFRP-1 to ex vivo perfusion-cultured human eyes decreased outflow facility, concomitant with reduced levels of β-catenin, the Wnt signaling mediator, in the TM. Intravitreal injection of an adenoviral vector encoding sFRP1 in mice produced a titer-dependent increase in IOP. Five days after vector injection, IOP increased 2 fold, which was significantly reduced by topical ocular administration of an inhibitor of a downstream suppressor of Wnt signaling. Thus, these data indicate that increased expression of sFRP1 in the TM appears to be responsible for elevated IOP in glaucoma and restoring Wnt signaling in the TM may be a novel disease intervention strategy for treating glaucoma. PMID:18274669
Scavuzzo-Duggan, Tess R.; Chaves, Arielle M.; Roberts, Alison W.
2015-07-14
Here, a method for rapid in vivo functional analysis of engineered proteins was developed using Physcomitrella patens. A complementation assay was designed for testing structure/function relationships in cellulose synthase (CESA) proteins. The components of the assay include (1) construction of test vectors that drive expression of epitope-tagged PpCESA5 carrying engineered mutations, (2) transformation of a ppcesa5 knockout line that fails to produce gametophores with test and control vectors, (3) scoring the stable transformants for gametophore production, (4) statistical analysis comparing complementation rates for test vectors to positive and negative control vectors, and (5) analysis of transgenic protein expression by Westernmore » blotting. The assay distinguished mutations that generate fully functional, nonfunctional, and partially functional proteins. In conclusion, compared with existing methods for in vivo testing of protein function, this complementation assay provides a rapid method for investigating protein structure/function relationships in plants.« less
Emerging Vector-Borne Diseases – Incidence through Vectors
Savić, Sara; Vidić, Branka; Grgić, Zivoslav; Potkonjak, Aleksandar; Spasojevic, Ljubica
2014-01-01
Vector-borne diseases use to be a major public health concern only in tropical and subtropical areas, but today they are an emerging threat for the continental and developed countries also. Nowadays, in intercontinental countries, there is a struggle with emerging diseases, which have found their way to appear through vectors. Vector-borne zoonotic diseases occur when vectors, animal hosts, climate conditions, pathogens, and susceptible human population exist at the same time, at the same place. Global climate change is predicted to lead to an increase in vector-borne infectious diseases and disease outbreaks. It could affect the range and population of pathogens, host and vectors, transmission season, etc. Reliable surveillance for diseases that are most likely to emerge is required. Canine vector-borne diseases represent a complex group of diseases including anaplasmosis, babesiosis, bartonellosis, borreliosis, dirofilariosis, ehrlichiosis, and leishmaniosis. Some of these diseases cause serious clinical symptoms in dogs and some of them have a zoonotic potential with an effect to public health. It is expected from veterinarians in coordination with medical doctors to play a fundamental role at primarily prevention and then treatment of vector-borne diseases in dogs. The One Health concept has to be integrated into the struggle against emerging diseases. During a 4-year period, from 2009 to 2013, a total number of 551 dog samples were analyzed for vector-borne diseases (borreliosis, babesiosis, ehrlichiosis, anaplasmosis, dirofilariosis, and leishmaniasis) in routine laboratory work. The analysis was done by serological tests – ELISA for borreliosis, dirofilariosis, and leishmaniasis, modified Knott test for dirofilariosis, and blood smear for babesiosis, ehrlichiosis, and anaplasmosis. This number of samples represented 75% of total number of samples that were sent for analysis for different diseases in dogs. Annually, on average more then half of the samples brought to the laboratory to analysis for different infectious diseases are analyzed for vector-borne diseases. In the region of Vojvodina (northern part of Serbia), the following vector-borne infectious diseases have been found in dogs so far borreliosis, babesiosis, dirofilariosis, leishmaniasis, and anaplasmosis. PMID:25520951
Emerging Vector-Borne Diseases - Incidence through Vectors.
Savić, Sara; Vidić, Branka; Grgić, Zivoslav; Potkonjak, Aleksandar; Spasojevic, Ljubica
2014-01-01
Vector-borne diseases use to be a major public health concern only in tropical and subtropical areas, but today they are an emerging threat for the continental and developed countries also. Nowadays, in intercontinental countries, there is a struggle with emerging diseases, which have found their way to appear through vectors. Vector-borne zoonotic diseases occur when vectors, animal hosts, climate conditions, pathogens, and susceptible human population exist at the same time, at the same place. Global climate change is predicted to lead to an increase in vector-borne infectious diseases and disease outbreaks. It could affect the range and population of pathogens, host and vectors, transmission season, etc. Reliable surveillance for diseases that are most likely to emerge is required. Canine vector-borne diseases represent a complex group of diseases including anaplasmosis, babesiosis, bartonellosis, borreliosis, dirofilariosis, ehrlichiosis, and leishmaniosis. Some of these diseases cause serious clinical symptoms in dogs and some of them have a zoonotic potential with an effect to public health. It is expected from veterinarians in coordination with medical doctors to play a fundamental role at primarily prevention and then treatment of vector-borne diseases in dogs. The One Health concept has to be integrated into the struggle against emerging diseases. During a 4-year period, from 2009 to 2013, a total number of 551 dog samples were analyzed for vector-borne diseases (borreliosis, babesiosis, ehrlichiosis, anaplasmosis, dirofilariosis, and leishmaniasis) in routine laboratory work. The analysis was done by serological tests - ELISA for borreliosis, dirofilariosis, and leishmaniasis, modified Knott test for dirofilariosis, and blood smear for babesiosis, ehrlichiosis, and anaplasmosis. This number of samples represented 75% of total number of samples that were sent for analysis for different diseases in dogs. Annually, on average more then half of the samples brought to the laboratory to analysis for different infectious diseases are analyzed for vector-borne diseases. In the region of Vojvodina (northern part of Serbia), the following vector-borne infectious diseases have been found in dogs so far borreliosis, babesiosis, dirofilariosis, leishmaniasis, and anaplasmosis.
NASA Astrophysics Data System (ADS)
Othman, Arsalan A.; Gloaguen, Richard
2017-09-01
Lithological mapping in mountainous regions is often impeded by limited accessibility due to relief. This study aims to evaluate (1) the performance of different supervised classification approaches using remote sensing data and (2) the use of additional information such as geomorphology. We exemplify the methodology in the Bardi-Zard area in NE Iraq, a part of the Zagros Fold - Thrust Belt, known for its chromite deposits. We highlighted the improvement of remote sensing geological classification by integrating geomorphic features and spatial information in the classification scheme. We performed a Maximum Likelihood (ML) classification method besides two Machine Learning Algorithms (MLA): Support Vector Machine (SVM) and Random Forest (RF) to allow the joint use of geomorphic features, Band Ratio (BR), Principal Component Analysis (PCA), spatial information (spatial coordinates) and multispectral data of the Advanced Space-borne Thermal Emission and Reflection radiometer (ASTER) satellite. The RF algorithm showed reliable results and discriminated serpentinite, talus and terrace deposits, red argillites with conglomerates and limestone, limy conglomerates and limestone conglomerates, tuffites interbedded with basic lavas, limestone and Metamorphosed limestone and reddish green shales. The best overall accuracy (∼80%) was achieved by Random Forest (RF) algorithms in the majority of the sixteen tested combination datasets.
Gori, Jennifer L.; Butler, Jason M.; Kunar, Balvir; Poulos, Michael G.; Ginsberg, Michael; Nolan, Daniel J.; Norgaard, Zachary K.; Adair, Jennifer E.; Rafii, Shahin
2016-01-01
Abstract Successful expansion of bone marrow (BM) hematopoietic stem and progenitor cells (HSPCs) would benefit many HSPC transplantation and gene therapy/editing applications. However, current expansion technologies have been limited by a loss of multipotency and self‐renewal properties ex vivo. We hypothesized that an ex vivo vascular niche would provide prohematopoietic signals to expand HSPCs while maintaining multipotency and self‐renewal. To test this hypothesis, BM autologous CD34+ cells were expanded in endothelial cell (EC) coculture and transplanted in nonhuman primates. CD34+C38− HSPCs cocultured with ECs expanded up to 17‐fold, with a significant increase in hematopoietic colony‐forming activity compared with cells cultured with cytokines alone (colony‐forming unit‐granulocyte‐erythroid‐macrophage‐monocyte; p < .005). BM CD34+ cells that were transduced with green fluorescent protein lentivirus vector and expanded on ECs engrafted long term with multilineage polyclonal reconstitution. Gene marking was observed in granulocytes, lymphocytes, platelets, and erythrocytes. Whole transcriptome analysis indicated that EC coculture altered the expression profile of 75 genes in the BM CD34+ cells without impeding the long‐term engraftment potential. These findings show that an ex vivo vascular niche is an effective platform for expansion of adult BM HSPCs. Stem Cells Translational Medicine 2017;6:864–876 PMID:28297579
NASA Astrophysics Data System (ADS)
Bedra, Sami; Bedra, Randa; Benkouda, Siham; Fortaki, Tarek
2017-12-01
In this paper, the effects of both anisotropies in the substrate and superstrate loading on the resonant frequency and bandwidth of high-Tc superconducting circular microstrip patch in a substrate-superstrate configuration are investigated. A rigorous analysis is performed using a dyadic Galerkin's method in the vector Hankel transform domain. Galerkin's procedure is employed in the spectral domain where the TM and TE modes of the cylindrical cavity with magnetic side walls are used in the expansion of the disk current. The effect of the superconductivity of the patch is taken into account using the concept of the complex resistive boundary condition. London's equations and the two-fluid model of Gorter and Casimir are used in the calculation of the complex surface impedance of the superconducting circular disc. The accuracy of the analysis is tested by comparing the computed results with previously published data for several anisotropic substrate-superstrate materials. Good agreement is found among all sets of results. The numerical results obtained show that important errors can be made in the computation of the resonant frequencies and bandwidths of the superconducting resonators when substrate dielectric anisotropy, and/or superstrate anisotropy are ignored. Other theoretical results obtained show that the superconducting circular microstrip patch on anisotropic substrate-superstrate with properly selected permittivity values along the optical and the non-optical axes combined with optimally chosen structural parameters is more advantageous than the one on isotropic substrate-superstrate by exhibiting wider bandwidth characteristic.
ERIC Educational Resources Information Center
Yiu, Chang-li; Wilde, Carroll O.
Vector analysis is viewed to play a key role in many branches of engineering and the physical sciences. This unit is geared towards deriving identities and establishing "machinery" to make derivations a routine task. It is noted that the module is not an applications unit, but has as its primary objective the goal of providing science,…
Current Advances and Future Challenges in Adenoviral Vector Biology and Targeting
Campos, Samuel K.; Barry, Michael A.
2008-01-01
Gene delivery vectors based on Adenoviral (Ad) vectors have enormous potential for the treatment of both hereditary and acquired disease. Detailed structural analysis of the Ad virion, combined with functional studies has broadened our knowledge of the structure/function relationships between Ad vectors and host cells/tissues and substantial achievement has been made towards a thorough understanding of the biology of Ad vectors. The widespread use of Ad vectors for clinical gene therapy is compromised by their inherent immunogenicity. The generation of safer and more effective Ad vectors, targeted to the site of disease, has therefore become a great ambition in the field of Ad vector development. This review provides a synopsis of the structure/function relationships between Ad vectors and host systems and summarizes the many innovative approaches towards achieving Ad vector targeting. PMID:17584037
VISMapper: ultra-fast exhaustive cartography of viral insertion sites for gene therapy.
Juanes, José M; Gallego, Asunción; Tárraga, Joaquín; Chaves, Felipe J; Marín-Garcia, Pablo; Medina, Ignacio; Arnau, Vicente; Dopazo, Joaquín
2017-09-20
The possibility of integrating viral vectors to become a persistent part of the host genome makes them a crucial element of clinical gene therapy. However, viral integration has associated risks, such as the unintentional activation of oncogenes that can result in cancer. Therefore, the analysis of integration sites of retroviral vectors is a crucial step in developing safer vectors for therapeutic use. Here we present VISMapper, a vector integration site analysis web server, to analyze next-generation sequencing data for retroviral vector integration sites. VISMapper can be found at: http://vismapper.babelomics.org . Because it uses novel mapping algorithms VISMapper is remarkably faster than previous available programs. It also provides a useful graphical interface to analyze the integration sites found in the genomic context.
Vectorization and parallelization of the finite strip method for dynamic Mindlin plate problems
NASA Technical Reports Server (NTRS)
Chen, Hsin-Chu; He, Ai-Fang
1993-01-01
The finite strip method is a semi-analytical finite element process which allows for a discrete analysis of certain types of physical problems by discretizing the domain of the problem into finite strips. This method decomposes a single large problem into m smaller independent subproblems when m harmonic functions are employed, thus yielding natural parallelism at a very high level. In this paper we address vectorization and parallelization strategies for the dynamic analysis of simply-supported Mindlin plate bending problems and show how to prevent potential conflicts in memory access during the assemblage process. The vector and parallel implementations of this method and the performance results of a test problem under scalar, vector, and vector-concurrent execution modes on the Alliant FX/80 are also presented.
Colwill, Karen; Wells, Clark D; Elder, Kelly; Goudreault, Marilyn; Hersi, Kadija; Kulkarni, Sarang; Hardy, W Rod; Pawson, Tony; Morin, Gregg B
2006-03-06
Recombinational systems have been developed to rapidly shuttle Open Reading Frames (ORFs) into multiple expression vectors in order to analyze the large number of cDNAs available in the post-genomic era. In the Creator system, an ORF introduced into a donor vector can be transferred with Cre recombinase to a library of acceptor vectors optimized for different applications. Usability of the Creator system is impacted by the ability to easily manipulate DNA, the number of acceptor vectors for downstream applications, and the level of protein expression from Creator vectors. To date, we have developed over 20 novel acceptor vectors that employ a variety of promoters and epitope tags commonly employed for proteomics applications and gene function analysis. We also made several enhancements to the donor vectors including addition of different multiple cloning sites to allow shuttling from pre-existing vectors and introduction of the lacZ alpha reporter gene to allow for selection. Importantly, in order to ameliorate any effects on protein expression of the loxP site between a 5' tag and ORF, we introduced a splicing event into our expression vectors. The message produced from the resulting 'Creator Splice' vector undergoes splicing in mammalian systems to remove the loxP site. Upon analysis of our Creator Splice constructs, we discovered that protein expression levels were also significantly increased. The development of new donor and acceptor vectors has increased versatility during the cloning process and made this system compatible with a wider variety of downstream applications. The modifications introduced in our Creator Splice system were designed to remove extraneous sequences due to recombination but also aided in downstream analysis by increasing protein expression levels. As a result, we can now employ epitope tags that are detected less efficiently and reduce our assay scale to allow for higher throughput. The Creator Splice system appears to be an extremely useful tool for proteomics.
Colwill, Karen; Wells, Clark D; Elder, Kelly; Goudreault, Marilyn; Hersi, Kadija; Kulkarni, Sarang; Hardy, W Rod; Pawson, Tony; Morin, Gregg B
2006-01-01
Background Recombinational systems have been developed to rapidly shuttle Open Reading Frames (ORFs) into multiple expression vectors in order to analyze the large number of cDNAs available in the post-genomic era. In the Creator system, an ORF introduced into a donor vector can be transferred with Cre recombinase to a library of acceptor vectors optimized for different applications. Usability of the Creator system is impacted by the ability to easily manipulate DNA, the number of acceptor vectors for downstream applications, and the level of protein expression from Creator vectors. Results To date, we have developed over 20 novel acceptor vectors that employ a variety of promoters and epitope tags commonly employed for proteomics applications and gene function analysis. We also made several enhancements to the donor vectors including addition of different multiple cloning sites to allow shuttling from pre-existing vectors and introduction of the lacZ alpha reporter gene to allow for selection. Importantly, in order to ameliorate any effects on protein expression of the loxP site between a 5' tag and ORF, we introduced a splicing event into our expression vectors. The message produced from the resulting 'Creator Splice' vector undergoes splicing in mammalian systems to remove the loxP site. Upon analysis of our Creator Splice constructs, we discovered that protein expression levels were also significantly increased. Conclusion The development of new donor and acceptor vectors has increased versatility during the cloning process and made this system compatible with a wider variety of downstream applications. The modifications introduced in our Creator Splice system were designed to remove extraneous sequences due to recombination but also aided in downstream analysis by increasing protein expression levels. As a result, we can now employ epitope tags that are detected less efficiently and reduce our assay scale to allow for higher throughput. The Creator Splice system appears to be an extremely useful tool for proteomics. PMID:16519801
Some Nonlinear Reconstruction Algorithms for Electrical Impedance Tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berryman, J G
2001-03-09
An impedance camera [Henderson and Webster, 1978; Dines and Lytle, 1981]--or what is now more commonly called electrical impedance tomography--attempts to image the electrical impedance (or just the conductivity) distribution inside a body using electrical measurements on its boundary. The method has been used successfully in both biomedical [Brown, 1983; Barber and Brown, 1986; J. C. Newell, D. G. Gisser, and D. Isaacson, 1988; Webster, 1990] and geophysical applications [Wexler, Fry, and Neurnan, 1985; Daily, Lin, and Buscheck, 1987], but the analysis of optimal reconstruction algorithms is still progressing [Murai and Kagawa, 1985; Wexler, Fry, and Neurnan, 1985; Kohn andmore » Vogelius, 1987; Yorkey and Webster, 1987; Yorkey, Webster, and Tompkins, 1987; Berryman and Kohn, 1990; Kohn and McKenney, 1990; Santosa and Vogelius, 1990; Yorkey, 1990]. The most common application is monitoring the influx or efflux of a highly conducting fluid (such as brine in a porous rock or blood in the human body) through the volume being imaged. For biomedical applications, this met hod does not have the resolution of radiological methods, but it is comparatively safe and inexpensive and therefore provides a valuable alternative when continuous monitoring of a patient or process is desired. The following discussion is intended first t o summarize the physics of electrical impedance tomography, then to provide a few details of the data analysis and forward modeling requirements, and finally to outline some of the reconstruction algorithms that have proven to be most useful in practice. Pointers to the literature are provided throughout this brief narrative and the reader is encouraged to explore the references for more complete discussions of the various issues raised here.« less
Chen, Qi; Wang, Dan; Cai, Gaozhe; Xiong, Yonghua; Li, Yuntao; Wang, Maohua; Huo, Huiling; Lin, Jianhan
2016-12-15
Early screening of pathogenic bacteria is a key to prevent and control of foodborne diseases. In this study, we developed a fast and sensitive bacteria detection method integrating electrochemical impedance analysis, urease catalysis with microfluidics and using Listeria as model. The Listeria cells, the anti-Listeria monoclonal antibodies modified magnetic nanoparticles (MNPs), and the anti-Listeria polyclonal antibodies and urease modified gold nanoparticles (AuNPs) were incubated in a fluidic separation chip with active mixing to form the MNP-Listeria-AuNP-urease sandwich complexes. The complexes were captured in the separation chip by applying a high gradient magnetic field, and the urea was injected to resuspend the complexes and hydrolyzed under the catalysis of the urease on the complexes into ammonium ions and carbonate ions, which were transported into a microfluidic detection chip with an interdigitated microelectrode for impedance measurement to determine the amount of the Listeria cells. The capture efficiency of the Listeria cells in the separation chip was ∼93% with a shorter time of 30min due to the faster immuno-reaction using the active magnetic mixing. The changes on both impedance magnitude and phase angle were demonstrated to be able to detect the Listeria cells as low as 1.6×10(2)CFU/mL. The detection time was reduced from original ∼2h to current ∼1h. The recoveries of the spiked lettuce samples ranged from 82.1% to 89.6%, indicating the applicability of this proposed biosensor. This microfluidic impedance biosensor has shown the potential for online, automatic and sensitive bacteria separation and detection. Copyright © 2016 Elsevier B.V. All rights reserved.
Piervirgili, G; Petracca, F; Merletti, R
2014-10-01
A model-based new procedure for measuring the single electrode-gel-skin impedance (ZEGS) is presented. The method is suitable for monitoring the contact impedance of the electrodes of a large array with limited modifications of the hardware and without removing or disconnecting the array from the amplifier. The procedure is based on multiple measurements between electrode pairs and is particularly suitable for electrode arrays. It has been applied to study the effectiveness of three skin treatments, with respect to no treatment, for reducing the electrode-gel-skin impedance (ZEGS) and noise: (i) rubbing with alcohol; (ii) rubbing with abrasive conductive paste; (iii) stripping with adhesive tape. The complex impedances ZEGS of the individual electrodes were measured by applying this procedure to disposable commercial Ag-AgCl gelled electrode arrays (4 × 1) with a 5 mm(2) contact area. The impedance unbalance ΔZ = ZEGS1 - ZEGS2 and the RMS noise (VRMS) were measured between pairs of electrodes. The tissue impedance ZT was also obtained, as a collateral result. Measurements were repeated at t0 = 0 min and at t30 = 30 min from the electrode application. Mixed linear models and linear regression analysis applied to ZEGS, ΔZ and noise VRMS for the skin treatment factor demonstrated (a) that skin rubbing with abrasive conductive paste is more effective in lowering ZEGS, ΔZ and VRMS (p < 0.01) than the other treatments or no treatment, and (b) a statistically significant decrement (p < 0.01), between t0 and t30, of magnitude and phase of ZEGS.Rubbing with abrasive conductive paste significantly decreased the noise VRMS with respect to other treatments or no treatment.
Savarino, Edoardo; Marabotto, Elisa; Zentilin, Patrizia; Frazzoni, Marzio; Sammito, Giorgio; Bonfanti, Daria; Sconfienza, Luca; Assandri, Lorenzo; Gemignani, Lorenzo; Malesci, Alberto; Savarino, Vincenzo
2011-07-01
Functional heartburn is defined by Rome III criteria as an endoscopy-negative condition with normal oesophageal acid exposure time, negative symptom association to acid reflux and unsatisfactory response to proton pump inhibitors. These criteria underestimated the role of non-acid reflux. To assess the contribution of impedance-pH with symptom association probability (SAP) analysis in identifying endoscopy-negative patients with reflux disease and separating them from functional heartburn. Consecutive endoscopy-negative patients treated with proton pump inhibitors (n=219) undergoing impedance-pH monitoring off-therapy were analysed. Distal acid exposure time, reflux episodes, SAP and symptomatic response to proton pump inhibitors were measured. Based on impedance-pH/SAP, 67 (31%) patients were pH+/SAP+, 6 (2%) pH+/SAP-, 83 (38%) hypersensitive oesophagus and 63 (29%) functional heartburn. According to pH-metry alone/response to proton pump inhibitors, 62 (28%) were pH+/SAP+, 11 (5%) pH+/SAP-, 61 (28%) hypersensitive oesophagus and 85 (39%) functional heartburn. In the normal-acid exposure population the contribution of impedance-pH/SAP compared to pH-metry alone/response to proton pump inhibitors in identifying patients with reflux disease and functional heartburn resulted to be 10%. In patients with abnormal-acid exposure, the contribution of impedance-pH/SAP increased by 3%. Comparing impedance-pH testing with pH-metry alone plus the response to proton pump inhibitor therapy demonstrated that the latter ones cause underestimation of reflux disease patients and overestimation of functional heartburn patients. Copyright © 2011 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Rutkove, Seward B; Geisbush, Tom R; Mijailovic, Aleksandar; Shklyar, Irina; Pasternak, Amy; Visyak, Nicole; Wu, Jim S; Zaidman, Craig; Darras, Basil T
2014-07-01
Electrical impedance myography and quantitative ultrasound are two noninvasive, painless, and effort-independent approaches for assessing neuromuscular disease. Both techniques have potential to serve as useful biomarkers in clinical trials in Duchenne muscular dystrophy. However, their comparative sensitivity to disease status and how they relate to one another are unknown. We performed a cross-sectional analysis of electrical impedance myography and quantitative ultrasound in 24 healthy boys and 24 with Duchenne muscular dystrophy, aged 2 to 14 years with trained research assistants performing all measurements. Three upper and three lower extremity muscles were studied unilaterally in each child, and the data averaged for each individual. Both electrical impedance myography and quantitative ultrasound differentiated healthy boys from those with Duchenne muscular dystrophy (P < 0.001 for both). Quantitative ultrasound values correlated with age in Duchenne muscular dystrophy boys (rho = 0.45; P = 0.029), whereas electrical impedance myography did not (rho = -0.31; P = 0.14). However, electrical impedance myography phase correlated with age in healthy boys (rho = 0.51; P = 0.012), whereas quantitative ultrasound did not (rho = -0.021; P = 0.92). In Duchenne muscular dystrophy boys, electrical impedance myography phase correlated with the North Star Ambulatory Assessment (rho = 0.65; P = 0.022); quantitative ultrasound revealed a near-significant association (rho = -0.56; P = 0.060). The two technologies trended toward a moderate correlation with one another in the Duchenne muscular dystrophy cohort but not in the healthy group (rho = -0.40; P = 0.054 and rho = -0.32; P = 0.13, respectively). Electrical impedance myography and quantitative ultrasound are complementary modalities for the assessment of boys with Duchenne muscular dystrophy; further study and application of these two modalities alone or in combination in a longitudinal fashion are warranted. Copyright © 2014 Elsevier Inc. All rights reserved.
Equivalent circuit models for interpreting impedance perturbation spectroscopy data
NASA Astrophysics Data System (ADS)
Smith, R. Lowell
2004-07-01
As in-situ structural integrity monitoring disciplines mature, there is a growing need to process sensor/actuator data efficiently in real time. Although smaller, faster embedded processors will contribute to this, it is also important to develop straightforward, robust methods to reduce the overall computational burden for practical applications of interest. This paper addresses the use of equivalent circuit modeling techniques for inferring structure attributes monitored using impedance perturbation spectroscopy. In pioneering work about ten years ago significant progress was associated with the development of simple impedance models derived from the piezoelectric equations. Using mathematical modeling tools currently available from research in ultrasonics and impedance spectroscopy is expected to provide additional synergistic benefits. For purposes of structural health monitoring the objective is to use impedance spectroscopy data to infer the physical condition of structures to which small piezoelectric actuators are bonded. Features of interest include stiffness changes, mass loading, and damping or mechanical losses. Equivalent circuit models are typically simple enough to facilitate the development of practical analytical models of the actuator-structure interaction. This type of parametric structure model allows raw impedance/admittance data to be interpreted optimally using standard multiple, nonlinear regression analysis. One potential long-term outcome is the possibility of cataloging measured viscoelastic properties of the mechanical subsystems of interest as simple lists of attributes and their statistical uncertainties, whose evolution can be followed in time. Equivalent circuit models are well suited for addressing calibration and self-consistency issues such as temperature corrections, Poisson mode coupling, and distributed relaxation processes.
Assessing the immediate impact of botulinum toxin injection on impedance of spastic muscle.
Li, Xiaoyan; Shin, Henry; Li, Le; Magat, Elaine; Li, Sheng; Zhou, Ping
2017-05-01
This study aimed to investigate the immediate impacts of Botulinum Toxin A (BoNT-A) injections on the inherent electrical properties of spastic muscles using a newly developed electrical impedance myography (EIM) technique. Impedance measures were performed before and after a BoNT-A injection in biceps brachii muscles of 14 subjects with spasticity. Three major impedance variables, resistance (R), reactance (X) and phase angle (θ) were obtained from three different configurations, and were evaluated using the conventional EIM frequency at 50kHz as well as multiple frequency analysis. Statistical analysis demonstrated a significant decrease of resistance in the injected muscles (Multiple-frequency: R pre =25.17±1.94Ohm, R post =23.65±1.63Ohm, p<0.05; 50kHz: R pre =29.06±2.16Ohm, R post =27.7±1.89Ohm, p<0.05). Despite this decrease, there were no substantial changes in the reactance, phase angle, or anisotropy features after a BoNT-A injection. The significant changes of muscle resistance were most likely associated with the liquid injection of the BoNT-A-saline solution rather than the immediate toxin effects on the muscle. This study demonstrated high sensitivity of the EIM technique in the detection of alterations to muscle composition. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Rouse, Elliott J; Hargrove, Levi J; Perreault, Eric J; Peshkin, Michael A; Kuiken, Todd A
2013-08-01
The mechanical properties of human joints (i.e., impedance) are constantly modulated to precisely govern human interaction with the environment. The estimation of these properties requires the displacement of the joint from its intended motion and a subsequent analysis to determine the relationship between the imposed perturbation and the resultant joint torque. There has been much investigation into the estimation of upper-extremity joint impedance during dynamic activities, yet the estimation of ankle impedance during walking has remained a challenge. This estimation is important for understanding how the mechanical properties of the human ankle are modulated during locomotion, and how those properties can be replicated in artificial prostheses designed to restore natural movement control. Here, we introduce a mechatronic platform designed to address the challenge of estimating the stiffness component of ankle impedance during walking, where stiffness denotes the static component of impedance. The system consists of a single degree of freedom mechatronic platform that is capable of perturbing the ankle during the stance phase of walking and measuring the response torque. Additionally, we estimate the platform's intrinsic inertial impedance using parallel linear filters and present a set of methods for estimating the impedance of the ankle from walking data. The methods were validated by comparing the experimentally determined estimates for the stiffness of a prosthetic foot to those measured from an independent testing machine. The parallel filters accurately estimated the mechatronic platform's inertial impedance, accounting for 96% of the variance, when averaged across channels and trials. Furthermore, our measurement system was found to yield reliable estimates of stiffness, which had an average error of only 5.4% (standard deviation: 0.7%) when measured at three time points within the stance phase of locomotion, and compared to the independently determined stiffness values of the prosthetic foot. The mechatronic system and methods proposed in this study are capable of accurately estimating ankle stiffness during the foot-flat region of stance phase. Future work will focus on the implementation of this validated system in estimating human ankle impedance during the stance phase of walking.
Sheela, A M; Sarun, S; Justus, J; Vineetha, P; Sheeja, R V
2015-04-01
Vector borne diseases are a threat to human health. Little attention has been paid to the prevention of these diseases. We attempted to identify the significant wetland characteristics associated with the spread of chikungunya, dengue fever and malaria in Kerala, a tropical region of South West India using multivariate analyses (hierarchical cluster analysis, factor analysis and multiple regression). High/medium turbid coastal lagoons and inland water-logged wetlands with aquatic vegetation have significant effect on the incidence of chikungunya while dengue influenced by high turbid coastal beaches and malaria by medium turbid coastal beaches. The high turbidity in water is due to the urban waste discharge namely sewage, sullage and garbage from the densely populated cities and towns. The large extent of wetland is low land area favours the occurrence of vector borne diseases. Hence the provision of pollution control measures at source including soil erosion control measures is vital. The identification of vulnerable zones favouring the vector borne diseases will help the authorities to control pollution especially from urban areas and prevent these vector borne diseases. Future research should cover land use cover changes, climatic factors, seasonal variations in weather and pollution factors favouring the occurrence of vector borne diseases.
A multicolor panel of novel lentiviral "gene ontology" (LeGO) vectors for functional gene analysis.
Weber, Kristoffer; Bartsch, Udo; Stocking, Carol; Fehse, Boris
2008-04-01
Functional gene analysis requires the possibility of overexpression, as well as downregulation of one, or ideally several, potentially interacting genes. Lentiviral vectors are well suited for this purpose as they ensure stable expression of complementary DNAs (cDNAs), as well as short-hairpin RNAs (shRNAs), and can efficiently transduce a wide spectrum of cell targets when packaged within the coat proteins of other viruses. Here we introduce a multicolor panel of novel lentiviral "gene ontology" (LeGO) vectors designed according to the "building blocks" principle. Using a wide spectrum of different fluorescent markers, including drug-selectable enhanced green fluorescent protein (eGFP)- and dTomato-blasticidin-S resistance fusion proteins, LeGO vectors allow simultaneous analysis of multiple genes and shRNAs of interest within single, easily identifiable cells. Furthermore, each functional module is flanked by unique cloning sites, ensuring flexibility and individual optimization. The efficacy of these vectors for analyzing multiple genes in a single cell was demonstrated in several different cell types, including hematopoietic, endothelial, and neural stem and progenitor cells, as well as hepatocytes. LeGO vectors thus represent a valuable tool for investigating gene networks using conditional ectopic expression and knock-down approaches simultaneously.
Statistical analysis of dispersion relations in turbulent solar wind fluctuations using Cluster data
NASA Astrophysics Data System (ADS)
Perschke, C.; Narita, Y.
2012-12-01
Multi-spacecraft measurements enable us to resolve three-dimensional spatial structures without assuming Taylor's frozen-in-flow hypothesis. This is very useful to study frequency-wave vector diagram in solar wind turbulence through direct determination of three-dimensional wave vectors. The existence and evolution of dispersion relation and its role in fully-developed plasma turbulence have been drawing attention of physicists, in particular, if solar wind turbulence represents kinetic Alfvén or whistler mode as the carrier of spectral energy among different scales through wave-wave interactions. We investigate solar wind intervals of Cluster data for various flow velocities with a high-resolution wave vector analysis method, Multi-point Signal Resonator technique, at the tetrahedral separation about 100 km. Magnetic field data and ion data are used to determine the frequency- wave vector diagrams in the co-moving frame of the solar wind. We find primarily perpendicular wave vectors in solar wind turbulence which justify the earlier discussions about kinetic Alfvén or whistler wave. The frequency- wave vector diagrams confirm (a) wave vector anisotropy and (b) scattering in frequencies.
Vector adaptive predictive coder for speech and audio
NASA Technical Reports Server (NTRS)
Chen, Juin-Hwey (Inventor); Gersho, Allen (Inventor)
1990-01-01
A real-time vector adaptive predictive coder which approximates each vector of K speech samples by using each of M fixed vectors in a first codebook to excite a time-varying synthesis filter and picking the vector that minimizes distortion. Predictive analysis for each frame determines parameters used for computing from vectors in the first codebook zero-state response vectors that are stored at the same address (index) in a second codebook. Encoding of input speech vectors s.sub.n is then carried out using the second codebook. When the vector that minimizes distortion is found, its index is transmitted to a decoder which has a codebook identical to the first codebook of the decoder. There the index is used to read out a vector that is used to synthesize an output speech vector s.sub.n. The parameters used in the encoder are quantized, for example by using a table, and the indices are transmitted to the decoder where they are decoded to specify transfer characteristics of filters used in producing the vector s.sub.n from the receiver codebook vector selected by the vector index transmitted.
Kesari, Shreekant; Bhunia, Gouri Sankar; Kumar, Vijay; Jeyaram, Algarswamy; Ranjan, Alok; Das, Pradeep
2011-08-01
In visceral leishmaniasis, phlebotomine vectors are targets for control measures. Understanding the ecosystem of the vectors is a prerequisite for creating these control measures. This study endeavours to delineate the suitable locations of Phlebotomus argentipes with relation to environmental characteristics between endemic and non-endemic districts in India. A cross-sectional survey was conducted on 25 villages in each district. Environmental data were obtained through remote sensing images and vector density was measured using a CDC light trap. Simple linear regression analysis was used to measure the association between climatic parameters and vector density. Using factor analysis, the relationship between land cover classes and P. argentipes density among the villages in both districts was investigated. The results of the regression analysis indicated that indoor temperature and relative humidity are the best predictors for P. argentipes distribution. Factor analysis confirmed breeding preferences for P. argentipes by landscape element. Minimum Normalised Difference Vegetation Index, marshy land and orchard/settlement produced high loading in an endemic region, whereas water bodies and dense forest were preferred in non-endemic sites. Soil properties between the two districts were studied and indicated that soil pH and moisture content is higher in endemic sites compared to non-endemic sites. The present study should be utilised to make critical decisions for vector surveillance and controlling Kala-azar disease vectors.
Impedance Changes Indicate Proximal Ventriculoperitoneal Shunt Obstruction In Vitro.
Basati, Sukhraaj; Tangen, Kevin; Hsu, Ying; Lin, Hanna; Frim, David; Linninger, Andreas
2015-12-01
Extracranial cerebrospinal fluid (CSF) shunt obstruction is one of the most important problems in hydrocephalus patient management. Despite ongoing research into better shunt design, robust and reliable detection of shunt malfunction remains elusive. The authors present a novel method of correlating degree of tissue ingrowth into ventricular CSF drainage catheters with internal electrical impedance. The impedance based sensor is able to continuously monitor shunt patency using intraluminal electrodes. Prototype obstruction sensors were fabricated for in-vitro analysis of cellular ingrowth into a shunt under static and dynamic flow conditions. Primary astrocyte cell lines and C6 glioma cells were allowed to proliferate up to 7 days within a shunt catheter and the impedance waveform was observed. During cell ingrowth a significant change in the peak-to-peak voltage signal as well as the root-mean-square voltage level was observed, allowing the impedance sensor to potentially anticipate shunt malfunction long before it affects fluid drainage. Finite element modeling was employed to demonstrate that the electrical signal used to monitor tissue ingrowth is contained inside the catheter lumen and does not endanger tissue surrounding the shunt. These results may herald the development of "next generation" shunt technology that allows prediction of malfunction before it affects patient outcome.
Ortega, José Marcos; Sánchez, Isidro; Climent, Miguel Ángel
2017-09-25
Today, the characterisation of the microstructure of cement-based materials using non-destructive techniques has become an important topic of study, and among them, the impedance spectroscopy has recently experienced great progress. In this research, mortars with two different contents of fly ash were exposed to four different constant temperature and relative humidity environments during a 180-day period. The evolution of their microstructure was studied using impedance spectroscopy, whose results were contrasted with mercury intrusion porosimetry. The hardening environment has an influence on the microstructure of fly ash cement mortars. On one hand, the impedance resistances R₁ and R₂ are more influenced by the drying of the materials than by microstructure development, so they are not suitable for following the evolution of the porous network under non-optimum conditions. On the other hand, the impedance spectroscopy capacitances C₁ and C₂ allow studying the microstructure development of fly ash cement mortars exposed to those conditions, and their results are in accordance with mercury intrusion porosimetry ones. Finally, it has been observed that the combined analysis of the abovementioned capacitances could be very useful for studying shrinkage processes in cement-based materials kept in low relative humidity environments.
NASA Astrophysics Data System (ADS)
Gordon, Isabel Jiménez; Genies, Sylvie; Si Larbi, Gregory; Boulineau, Adrien; Daniel, Lise; Alias, Mélanie
2016-03-01
Understanding ageing mechanisms of Li-ion batteries is essential for further optimizations. To determine performance loss causes, post-mortem analyses are commonly applied. For each type of post-mortem test, different sample preparation protocols are adopted. However, reports on the reliability of these protocols are rare. Herein, Li-ion pouch cells with LiNi1/3Mn1/3Co1/3O2 - polyvinylidene fluoride positive electrode, graphite-carboxymethyl cellulose-styrene rubber negative electrode and LiPF6 - carbonate solvents mixture electrolyte, are opened and electrodes are recovered following a specified protocol. Negative and positive symmetric cells are assembled and their impedances are recorded. A signal analysis is applied to reconstruct the Li-ion pouch cell impedance from the symmetric cells, then comparison against the pouch cell true impedance allows the evaluation of the sample preparation protocols. The results are endorsed by Transmission Electronic Microscopy (TEM) and Gas Chromatography - Mass Spectrometry (GC-MS) analyses. Carbonate solvents used to remove the salt impacts slightly the surface properties of both electrodes. Drying electrodes under vacuum at 25 °C produces an impedance increase, particularly very marked for the positive electrode. Drying at 50 °C under vacuum or/and exposition to the anhydrous room atmosphere is very detrimental.
Sensing of NO2 with Zirconium Hydroxide via Electrical Impedance Spectroscopy
NASA Astrophysics Data System (ADS)
Harris, Coleman; Soliz, Jennifer; Klevitch, Andrew; Rossin, Joseph; Fountain, Augustus, III; Peterson, Gregory; Hauser, Adam
Nitrogen Dioxide (NO2) is a brown gas mainly produced as a byproduct of burning fossil fuels, such as automobiles and power plants. Nitrogen oxides can form acid rain and smog by reacting with air, can form toxic organic nitrates by reacting with soil, and can react with oxygen in water, destroying marine life due to a lack of breathable oxygen. Any concentration beyond 53 ppb (air quality standard) can cause irritation to the lungs and respiratory infections, and higher dosages can be fatal. As such, research in NO2 detection is incredibly important to human welfare. Zirconium hydroxide (Zr(OH)4) has been investigated as a candidate NO2 dielectric sensor using impedance spectroscopy analysis. Impedance changes of several orders of magnitude are seen down to our dosage minimum of 50 ppmhr. Changes in impedance correlate with nitrogen and oxygen atomic ratio increases observed via X-ray photoelectron spectroscopy (XPS). The results indicate that Zr(OH)4 may be a strong candidate for use in impedance-based NO2 detection devices. A.J.H., J.R.S., A.W.F. and G.W. P. acknowledge funding under Army Research Office STIR Award #W911F-15-1-0104. J.R.S. acknowledges funding under a NRC fellowship and is advised by Dr. Christopher Karwacki, ECBC.
2012-01-01
Background Analysis is lacking on the management of vector control systems in disease-endemic countries with respect to the efficiency and sustainability of operations. Methods Three locations were selected, at the scale of province, municipality and barangay (i.e. village). Data on disease incidence, programme activities, and programme management were collected on-site through meetings and focus group discussions. Results Adaptation of disease control strategies to the epidemiological situation per barangay, through micro-stratification, brings gains in efficiency, but should be accompanied by further capacity building on local situational analysis for better selection and targeting of vector control interventions within the barangay. An integrated approach to vector control, aiming to improve the rational use of resources, was evident with a multi-disease strategy for detection and response, and by the use of combinations of vector control methods. Collaboration within the health sector was apparent from the involvement of barangay health workers, re-orientation of job descriptions and the creation of a disease surveillance unit. The engagement of barangay leaders and use of existing community structures helped mobilize local resources and voluntary services for vector control. In one location, local authorities and the community were involved in the planning, implementation and evaluation of malaria control, which triggered local programme ownership. Conclusions Strategies that contributed to an improved efficiency and sustainability of vector control operations were: micro-stratification, integration of vector control within the health sector, a multi-disease approach, involvement of local authorities, and empowerment of communities. Capacity building on situational analysis and vector surveillance should be addressed through national policy and guidelines. PMID:22873707
DOT National Transportation Integrated Search
1996-06-01
Risk analysis plays a key role in the implementation of an architecture. Early definition of the situations, processes, or events that have the potential for impeding the implementation of key elements of the ITS National Architecture is a critical e...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhatia, Harsh
This dissertation presents research on addressing some of the contemporary challenges in the analysis of vector fields—an important type of scientific data useful for representing a multitude of physical phenomena, such as wind flow and ocean currents. In particular, new theories and computational frameworks to enable consistent feature extraction from vector fields are presented. One of the most fundamental challenges in the analysis of vector fields is that their features are defined with respect to reference frames. Unfortunately, there is no single “correct” reference frame for analysis, and an unsuitable frame may cause features of interest to remain undetected, thusmore » creating serious physical consequences. This work develops new reference frames that enable extraction of localized features that other techniques and frames fail to detect. As a result, these reference frames objectify the notion of “correctness” of features for certain goals by revealing the phenomena of importance from the underlying data. An important consequence of using these local frames is that the analysis of unsteady (time-varying) vector fields can be reduced to the analysis of sequences of steady (timeindependent) vector fields, which can be performed using simpler and scalable techniques that allow better data management by accessing the data on a per-time-step basis. Nevertheless, the state-of-the-art analysis of steady vector fields is not robust, as most techniques are numerical in nature. The residing numerical errors can violate consistency with the underlying theory by breaching important fundamental laws, which may lead to serious physical consequences. This dissertation considers consistency as the most fundamental characteristic of computational analysis that must always be preserved, and presents a new discrete theory that uses combinatorial representations and algorithms to provide consistency guarantees during vector field analysis along with the uncertainty visualization of unavoidable discretization errors. Together, the two main contributions of this dissertation address two important concerns regarding feature extraction from scientific data: correctness and precision. The work presented here also opens new avenues for further research by exploring more-general reference frames and more-sophisticated domain discretizations.« less
Modeling and analysis on ring-type piezoelectric transformers.
Ho, Shine-Tzong
2007-11-01
This paper presents an electromechanical model for a ring-type piezoelectric transformer (PT). To establish this model, vibration characteristics of the piezoelectric ring with free boundary conditions are analyzed in advance. Based on the vibration analysis of the piezoelectric ring, the operating frequency and vibration mode of the PT are chosen. Then, electromechanical equations of motion for the PT are derived based on Hamilton's principle, which can be used to simulate the coupled electromechanical system for the transformer. Such as voltage stepup ratio, input impedance, output impedance, input power, output power, and efficiency are calculated by the equations. The optimal load resistance and the maximum efficiency for the PT will be presented in this paper. Experiments also were conducted to verify the theoretical analysis, and a good agreement was obtained.
The numerical simulation of a high-speed axial flow compressor
NASA Technical Reports Server (NTRS)
Mulac, Richard A.; Adamczyk, John J.
1991-01-01
The advancement of high-speed axial-flow multistage compressors is impeded by a lack of detailed flow-field information. Recent development in compressor flow modeling and numerical simulation have the potential to provide needed information in a timely manner. The development of a computer program is described to solve the viscous form of the average-passage equation system for multistage turbomachinery. Programming issues such as in-core versus out-of-core data storage and CPU utilization (parallelization, vectorization, and chaining) are addressed. Code performance is evaluated through the simulation of the first four stages of a five-stage, high-speed, axial-flow compressor. The second part addresses the flow physics which can be obtained from the numerical simulation. In particular, an examination of the endwall flow structure is made, and its impact on blockage distribution assessed.
Dynamics modeling for parallel haptic interfaces with force sensing and control.
Bernstein, Nicholas; Lawrence, Dale; Pao, Lucy
2013-01-01
Closed-loop force control can be used on haptic interfaces (HIs) to mitigate the effects of mechanism dynamics. A single multidimensional force-torque sensor is often employed to measure the interaction force between the haptic device and the user's hand. The parallel haptic interface at the University of Colorado (CU) instead employs smaller 1D force sensors oriented along each of the five actuating rods to build up a 5D force vector. This paper shows that a particular manipulandum/hand partition in the system dynamics is induced by the placement and type of force sensing, and discusses the implications on force and impedance control for parallel haptic interfaces. The details of a "squaring down" process are also discussed, showing how to obtain reduced degree-of-freedom models from the general six degree-of-freedom dynamics formulation.
NASA Astrophysics Data System (ADS)
Gambina, Federico
In this study, the corrosion protection provided by of a number of chromate and chromate-free coatings systems was characterized in detail. High-solids SrCrO4-pigmented epoxy primers applied to 2024 and 7075 substrates were subject to salt spray exposure testing for 30 days. Samples were removed periodically and an electrochemical impedance measurement (EIS) was made. Although none of the coatings tested showed visual evidence of corrosion, the total impedance of the samples decreased by as much as two orders of magnitude. An analysis of capacitance showed that the primer coatings rapidly took up water from the exposure environment, but the coating-metal remained passive despite the fact that it was wet. These results support the idea that chromate coatings protect by creating a chromate-rich electrolyte within the coating that is passivating to the underlying metal substrate. They also suggest that indications of metal substrate passivity found in the low-frequency capacitive reactance of the impedance spectra are a better indicator of corrosion protection than the total impedance. The low-frequency capacitive reactance from EIS measurements is also good at assessing the protectiveness of chromate-free coatings systems. Fifteen different coatings systems comprising high-solids, chromate-free primers and chromate-free conversion coatings were applied to 2024 and 7075 substrates. These coatings were subject to salt spray exposure and EIS measurements. All coatings were inferior to coating systems containing chromate, but changes in the capacitive reactance measured in EIS was shown to anticipate visual indications of coating failure. A predictive model based on neural networks was trained to recognize the pattern in the capacitive reactance in impedance spectra measured after 48 hours of exposure and make an estimate of remaining coating life. A sensitivity analysis was performed to prune the impedance inputs. As a result of this analysis, a very simple but highly predictive model was constructed that used low-frequency phase angle information extracted directly from EIS measurements to predict time to failure in salt spray up to 30 days of exposure. The exposure and EIS characterization of the chromate-free coatings systems enabled a ranking of the coatings systems in terms of corrosion protection provided. Coating systems were ranked according to several different methods described in the literature. Among the coatings evaluated, Deft 02GN084, a high solids, solvent-borne and Pr-containing primer coating showed best protection when used in conjunction with a number of different conversion coatings and surface pretreatments. Several different trivalent chromium conversion coatings and pretreatment were used. This general type of conversion coating appeared to provide better corrosion protection than other pretreatments whose functions were primarily surface cleaning or adhesion promotion.
Short-stack modeling of degradation in solid oxide fuel cells. Part I. Contact degradation
NASA Astrophysics Data System (ADS)
Gazzarri, J. I.; Kesler, O.
As the first part of a two paper series, we present a two-dimensional impedance model of a working solid oxide fuel cell (SOFC) to study the effect of contact degradation on the impedance spectrum for the purpose of non-invasive diagnosis. The two dimensional modeled geometry includes the ribbed interconnect, and is adequate to represent co- and counter-flow configurations. Simulated degradation modes include: cathode delamination, interconnect oxidation, and interconnect-cathode detachment. The simulations show differences in the way each degradation mode impacts the impedance spectrum shape, suggesting that identification is possible. In Part II, we present a sensitivity analysis of the results to input parameter variability that reveals strengths and limitations of the method, as well as describing possible interactions between input parameters and concurrent degradation modes.
Stability testing and analysis of a PMAD dc test bed for the Space Station Freedom
NASA Technical Reports Server (NTRS)
Button, Robert M.; Brush, Andrew S.
1992-01-01
The Power Management and Distribution (PMAD) dc Test Bed at the NASA Lewis Research Center is introduced. Its usefulness to the Space Station Freedom Electrical Power (EPS) development and design are discussed in context of verifying system stability. Stability criteria developed by Middlebrook and Cuk are discussed as they apply to constant power dc to dc converters exhibiting negative input impedance at low frequencies. The utility-type Secondary Subsystem is presented and each component is described. The instrumentation used to measure input and output impedance under load is defined. Test results obtained from input and output impedance measurements of test bed components are presented. It is shown that the PMAD dc Test Bed Secondary Subsystem meets the Middlebrook stability criterion for certain loading conditions.
Stability Testing and Analysis of a PMAD DC Test Bed for the Space Station Freedom
NASA Technical Reports Server (NTRS)
Button, Robert M.; Brush, Andrew S.
1992-01-01
The Power Management and Distribution (PMAD) DC Test Bed at the NASA Lewis Research Center is introduced. Its usefulness to the Space Station Freedom Electrical Power (EPS) development and design are discussed in context of verifying system stability. Stability criteria developed by Middlebrook and Cuk are discussed as they apply to constant power DC to DC converters exhibiting negative input impedance at low frequencies. The utility-type Secondary Subsystem is presented and each component is described. The instrumentation used to measure input and output impedance under load is defined. Test results obtained from input and output impedance measurements of test bed components are presented. It is shown that the PMAD DC Test Bed Secondary Subsystem meets the Middlebrook stability criterion for certain loading conditions.
Rate limiting mechanisms in lithium-molybdenum disulfide batteries
NASA Astrophysics Data System (ADS)
Laman, F. C.; Stiles, J. A. R.; Brandt, K.; Shank, R. J.
1985-03-01
One limitation of secondary lithium batteries using intercalation cathodes is generally related to relatively low power densities. Significant advances towards overcoming this limitation have been made in cells based on a utilization of lithium-molybdenum disulfide technology. Rate limiting mechanisms in cells of the lithium-molybdenum disulfide system have been studied with the aid of a frequency response analysis. It was found that diffusion-related contributions to cell impedance, and interfacial and resistive contributions to cell impedance, can be readily segregated by virtue of the fact that the diffusion-controlled mechanisms dominate the low frequency end of the impedance spectra, while the other mechanisms dominate the high frequency end. The present investigation is concerned with rate limitations at the high end of the frequency spectrum in lithium-molybdenum disulfide cathodes.
Frequency response of electrochemical cells
NASA Technical Reports Server (NTRS)
Thomas, Daniel L.
1989-01-01
Impedance concepts can be applied to the analysis of battery electrodes, yielding information about the structure of the electrode and the processes occurring in the electrode. Structural parameters such as the specific area (surface area per gram of electrode) can be estimated. Electrode variables such as surface overpotential, ohmic losses, and diffusion limitations may be studied. Nickel and cadmium electrodes were studied by measuring the ac impedance as a function of frequency, and the specific areas that were determined were well within the range of specific areas determined from BET measurements. Impedance spectra were measured for the nickel and cadmium electrodes, and for a 20 A-hr NiCd battery as functions of the state of charge. More work is needed to determine the feasibility of using frequency response as a nondestructive testing technique for batteries.
Robust Magnetotelluric Impedance Estimation
NASA Astrophysics Data System (ADS)
Sutarno, D.
2010-12-01
Robust magnetotelluric (MT) response function estimators are now in standard use by the induction community. Properly devised and applied, these have ability to reduce the influence of unusual data (outliers). The estimators always yield impedance estimates which are better than the conventional least square (LS) estimation because the `real' MT data almost never satisfy the statistical assumptions of Gaussian distribution and stationary upon which normal spectral analysis is based. This paper discuses the development and application of robust estimation procedures which can be classified as M-estimators to MT data. Starting with the description of the estimators, special attention is addressed to the recent development of a bounded-influence robust estimation, including utilization of the Hilbert Transform (HT) operation on causal MT impedance functions. The resulting robust performances are illustrated using synthetic as well as real MT data.
Least-cost transportation networks predict spatial interaction of invasion vectors.
Drake, D Andrew R; Mandrak, Nicholas E
2010-12-01
Human-mediated dispersal among aquatic ecosystems often results in biotic transfer between drainage basins. Such activities may circumvent biogeographic factors, with considerable ecological, evolutionary, and economic implications. However, the efficacy of predictions concerning community changes following inter-basin movements are limited, often because the dispersal mechanism is poorly understood (e.g., quantified only partially). To date, spatial-interaction models that predict the movement of humans as vectors of biotic transfer have not incorporated patterns of human movement through transportation networks. As a necessary first step to determine the role of anglers as invasion vectors across a land-lake ecosystem, we investigate their movement potential within Ontario, Canada. To determine possible model improvements resulting from inclusion of network travel, spatial-interaction models were constructed using standard Euclidean (e.g., straight-line) distance measures and also with distances derived from least-cost routing of human transportation networks. Model comparisons determined that least-cost routing both provided the most parsimonious model and also excelled at forecasting spatial interactions, with a proportion of 0.477 total movement deviance explained. The distribution of movements was characterized by many relatively short to medium travel distances (median = 292.6 km) with fewer lengthier distances (75th percentile = 484.6 km, 95th percentile = 775.2 km); however, even the shortest movements were sufficient to overcome drainage-basin boundaries. Ranking of variables in order of their contribution within the most parsimonious model determined that distance traveled, origin outflow, lake attractiveness, and sportfish richness significantly influence movement patterns. Model improvements associated with least-cost routing of human transportation networks imply that patterns of human-mediated invasion are fundamentally linked to the spatial configuration and relative impedance of human transportation networks, placing increased importance on understanding their contribution to the invasion process.
Computational mechanics analysis tools for parallel-vector supercomputers
NASA Technical Reports Server (NTRS)
Storaasli, Olaf O.; Nguyen, Duc T.; Baddourah, Majdi; Qin, Jiangning
1993-01-01
Computational algorithms for structural analysis on parallel-vector supercomputers are reviewed. These parallel algorithms, developed by the authors, are for the assembly of structural equations, 'out-of-core' strategies for linear equation solution, massively distributed-memory equation solution, unsymmetric equation solution, general eigensolution, geometrically nonlinear finite element analysis, design sensitivity analysis for structural dynamics, optimization search analysis and domain decomposition. The source code for many of these algorithms is available.
Sound transmission loss of composite sandwich panels
NASA Astrophysics Data System (ADS)
Zhou, Ran
Light composite sandwich panels are increasingly used in automobiles, ships and aircraft, because of the advantages they offer of high strength-to-weight ratios. However, the acoustical properties of these light and stiff structures can be less desirable than those of equivalent metal panels. These undesirable properties can lead to high interior noise levels. A number of researchers have studied the acoustical properties of honeycomb and foam sandwich panels. Not much work, however, has been carried out on foam-filled honeycomb sandwich panels. In this dissertation, governing equations for the forced vibration of asymmetric sandwich panels are developed. An analytical expression for modal densities of symmetric sandwich panels is derived from a sixth-order governing equation. A boundary element analysis model for the sound transmission loss of symmetric sandwich panels is proposed. Measurements of the modal density, total loss factor, radiation loss factor, and sound transmission loss of foam-filled honeycomb sandwich panels with different configurations and thicknesses are presented. Comparisons between the predicted sound transmission loss values obtained from wave impedance analysis, statistical energy analysis, boundary element analysis, and experimental values are presented. The wave impedance analysis model provides accurate predictions of sound transmission loss for the thin foam-filled honeycomb sandwich panels at frequencies above their first resonance frequencies. The predictions from the statistical energy analysis model are in better agreement with the experimental transmission loss values of the sandwich panels when the measured radiation loss factor values near coincidence are used instead of the theoretical values for single-layer panels. The proposed boundary element analysis model provides more accurate predictions of sound transmission loss for the thick foam-filled honeycomb sandwich panels than either the wave impedance analysis model or the statistical energy analysis model.
Richardson, John G [Idaho Falls, ID
2009-11-17
An impedance estimation method includes measuring three or more impedances of an object having a periphery using three or more probes coupled to the periphery. The three or more impedance measurements are made at a first frequency. Three or more additional impedance measurements of the object are made using the three or more probes. The three or more additional impedance measurements are made at a second frequency different from the first frequency. An impedance of the object at a point within the periphery is estimated based on the impedance measurements and the additional impedance measurements.
Vaxvec: The first web-based recombinant vaccine vector database and its data analysis
Deng, Shunzhou; Martin, Carly; Patil, Rasika; Zhu, Felix; Zhao, Bin; Xiang, Zuoshuang; He, Yongqun
2015-01-01
A recombinant vector vaccine uses an attenuated virus, bacterium, or parasite as the carrier to express a heterologous antigen(s). Many recombinant vaccine vectors and related vaccines have been developed and extensively investigated. To compare and better understand recombinant vectors and vaccines, we have generated Vaxvec (http://www.violinet.org/vaxvec), the first web-based database that stores various recombinant vaccine vectors and those experimentally verified vaccines that use these vectors. Vaxvec has now included 59 vaccine vectors that have been used in 196 recombinant vector vaccines against 66 pathogens and cancers. These vectors are classified to 41 viral vectors, 15 bacterial vectors, 1 parasitic vector, and 1 fungal vector. The most commonly used viral vaccine vectors are double-stranded DNA viruses, including herpesviruses, adenoviruses, and poxviruses. For example, Vaxvec includes 63 poxvirus-based recombinant vaccines for over 20 pathogens and cancers. Vaxvec collects 30 recombinant vector influenza vaccines that use 17 recombinant vectors and were experimentally tested in 7 animal models. In addition, over 60 protective antigens used in recombinant vector vaccines are annotated and analyzed. User-friendly web-interfaces are available for querying various data in Vaxvec. To support data exchange, the information of vaccine vectors, vaccines, and related information is stored in the Vaccine Ontology (VO). Vaxvec is a timely and vital source of vaccine vector database and facilitates efficient vaccine vector research and development. PMID:26403370
Intrasystem Analysis Program (IAP) Model Improvement.
1982-02-01
of Loop Antennas 2-117 2.11 Transmission Loss of Yagi-Uda Beam Antennas 2-120 2.12 Impedance Matching Factor of Frequency-Independent Antennas 2-121...2.16.5 Directive Gain Model for a Loop Antenna 2-181 2.16.6 Directive Gain Model for a Planer Log-Spiral Antenna 2-182 2.16.7 Directive Gain Model for...The published specifications for the antenns which meet certain standard requirements are based on measure- ments of the terminal impedance of the total
Input impedance of coaxially fed rectangular microstrip antenna on electrically thick substrate
NASA Technical Reports Server (NTRS)
Chen, Wei; Lee, Kai-Fong; Lee, R. Q.
1993-01-01
A full-wave spectral domain analysis has been used to obtain input-impedance results for a probe-fed rectangular-patch antenna, modeling the source as a magnetic-current frill. Multiple modes are used in the probe surface current to account for axial and azimuthal variations. It is established that maximum resistance is dependent on the substrate loss tangent. The axial variation of the probe current must be taken into account for substrate thicknesses greater than about 0.02 wavelengths.
NASA Astrophysics Data System (ADS)
Ravikiran, Y. T.; Vijaya Kumari, S. C.
2013-06-01
To innovate the properties of Polypyrrole/Titanium dioxide (PPy/TiO2) nanocomposite further, it has been synthesized by chemical polymerization technique. The nanostructure and monoclinic phase of the prepared composite have been confirmed by simulating the X-ray diffraction pattern (XRD). Also, complex plane impedance plot of the composite has been simulated to find equivalent resistance capacitance circuit (RC circuit) and numerical values of R and C have been predicted.
Plane wave diffraction by a finite plate with impedance boundary conditions.
Nawaz, Rab; Ayub, Muhammad; Javaid, Akmal
2014-01-01
In this study we have examined a plane wave diffraction problem by a finite plate having different impedance boundaries. The Fourier transforms were used to reduce the governing problem into simultaneous Wiener-Hopf equations which are then solved using the standard Wiener-Hopf procedure. Afterwards the separated and interacted fields were developed asymptotically by using inverse Fourier transform and the modified stationary phase method. Detailed graphical analysis was also made for various physical parameters we were interested in.
2010-08-02
properties of three gulf-coast species, Thalassia testudinum (turtle grass), Syringodium filiforme (manatee grass), and Halodule wrightii (shoal... Thalassia testudinum (turtle grass) is shown in Fig. 12. The two curves show plant volume fraction Vleaves/Vlot (measured by acoustic and image-based...cross-section image analysis (Fig. 13), was found to be X\\<*t = 0.23. Similar results were found the Thalassia testudinum (turtle grass) rhizomes
NASA Astrophysics Data System (ADS)
Miranda, David A.; Corzo, Sandra P.; González-Correa, Carlos-A.
2012-12-01
Electrical Impedance Spectroscopy (EIS) allows the study of the electrical properties of materials and structures such as biological tissues. EIS can be used as a diagnostic tool for the identification of pathological conditions such as cervical cancer. We used EIS in combination with genetic algorithms to characterize cervical epithelial squamous tissue in a heterogeneous sample of 56 Colombian women. All volunteers had a cytology taken for Papanicolau test and biopsy taken for histopathological analysis from those with a positive result (9 subjects). ROC analysis of the results suggest a sensitivity and specificity in the order of 0.73 and 0.86, respectively.
Electrical properties of Ba(Dy{sub 1/2}Nb{sub 1/2})O{sub 3} ceramic
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nath, K. Amar, E-mail: karn190@gmail.com; Chandra, K. P., E-mail: kpchandra23@gmail.com; Dubey, K., E-mail: kirandubey45@yahoo.com
2016-05-06
Polycrystalline Ba(Dy{sub 1/2}Nb{sub 1/2})O{sub 3} was prepared using a high-temperature solid-state reaction method. X-ray diffraction analysis indicated the formation of a single-phase cubic structure having space group Pm3m. AC impedance plots as a function of frequency at different temperatures were used to analyse the electrical behaviour of the sample, which indicated the negative temperature coefficient of resistance character. Complex impedance analysis targeted non-Debye type dielectric relaxation. Frequency dependent ac conductivity data obeyed Jonscher’s power law. The apparent activation energy was estimated to be 0.97 eV at 1 kHz.
Broadband infrared absorbers with stacked double chromium ring resonators
Deng, Huixu; Stan, Liliana; Czaplewski, David A.; ...
2017-10-31
A broadband absorber in the infrared wavelength range from 1 μm up to 5 μm is designed and demonstrated with stacked double chromium ring resonators on a reflective chromium mirror. The near-perfect broadband absorption is realized by combining the multilayer impedance match in the short wavelength range and the double plasmonic resonances in the long wavelength range, which is illustrated with an equivalent circuit model for the impedance analysis. The broadband absorber is proved to be angle-insensitive and polarization-independent due to the geometrical symmetry. Lastly, the thermal analysis for heat generation and temperature distributions inside the absorber structure is alsomore » investigated.« less
Broadband infrared absorbers with stacked double chromium ring resonators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deng, Huixu; Stan, Liliana; Czaplewski, David A.
A broadband absorber in the infrared wavelength range from 1 μm up to 5 μm is designed and demonstrated with stacked double chromium ring resonators on a reflective chromium mirror. The near-perfect broadband absorption is realized by combining the multilayer impedance match in the short wavelength range and the double plasmonic resonances in the long wavelength range, which is illustrated with an equivalent circuit model for the impedance analysis. The broadband absorber is proved to be angle-insensitive and polarization-independent due to the geometrical symmetry. Lastly, the thermal analysis for heat generation and temperature distributions inside the absorber structure is alsomore » investigated.« less
NASA Astrophysics Data System (ADS)
Wu, Xiaoyu; Hao, Zhenqi; Wu, Di; Zheng, Lu; Jiang, Zhanzhi; Ganesan, Vishal; Wang, Yayu; Lai, Keji
2018-04-01
We report quantitative measurements of nanoscale permittivity and conductivity using tuning-fork (TF) based microwave impedance microscopy (MIM). The system is operated under the driving amplitude modulation mode, which ensures satisfactory feedback stability on samples with rough surfaces. The demodulated MIM signals on a series of bulk dielectrics are in good agreement with results simulated by finite-element analysis. Using the TF-MIM, we have visualized the evolution of nanoscale conductance on back-gated MoS2 field effect transistors, and the results are consistent with the transport data. Our work suggests that quantitative analysis of mesoscopic electrical properties can be achieved by near-field microwave imaging with small distance modulation.
NASA Astrophysics Data System (ADS)
Scott, J. P.; Wentz, F. J.; Hoffman, R. N.; Atlas, R. M.
2016-02-01
Ocean vector wind is a valuable climate data record (CDR) useful in observing and monitoring changes in climate and air-sea interactions. Ocean surface wind stress influences such processes as heat, moisture, and momentum fluxes between the atmosphere and ocean, driving ocean currents and forcing ocean circulation. The Cross-Calibrated Multi-Platform (CCMP) ocean vector wind analysis is a quarter-degree, six-hourly global ocean wind analysis product created using the variational analysis method (VAM) [Atlas et al., 1996; Hoffman et al., 2003]. The CCMP V1.1 wind product is a highly-esteemed, widely-used data set containing the longest gap-free record of satellite-based ocean vector wind data (July 1987 to June 2012). CCMP V1.1 was considered a "first-look" data set that used the most-timely, albeit preliminary, releases of satellite, in situ, and modeled ECMWF-Operational wind background fields. The authors have been working with the original producers of CCMP V1.1 to create an updated, improved, and consistently-reprocessed CCMP V2.0 ocean vector wind analysis data set. With Remote Sensing Systems (RSS) having recently updated all passive microwave satellite instrument calibrations and retrievals to the RSS Version-7 RTM standard, the reprocessing of the CCMP data set into a higher-quality CDR using inter-calibrated satellite inputs became feasible. In addition to the use of SSM/I, SSMIS, TRMM TMI, QuikSCAT, AMSRE, and WindSat instruments, AMSR2, GMI, and ASCAT have been also included in the CCMP V2.0 data set release, which has now been extended to the beginning of 2015. Additionally, the background field has been updated to use six-hourly, quarter-degree ERA-Interim wind vector inputs, and the quality-checks on the in situ data have been carefully reviewed and improved. The goal of the release of the CCMP V2.0 ocean wind vector analysis product is to serve as a merged ocean wind vector data set for climate studies. Diligent effort has been made by the authors to minimize systematic and spurious sources of error. The authors will present a complete discussion of upgrades made to the CCMP V2.0 data set, as well as present validation work that has been completed on the CCMP V2.0 wind analysis product.
CdTe-TiO2 nanocomposite: an impeder of bacterial growth and biofilm
NASA Astrophysics Data System (ADS)
Gholap, Haribhau; Patil, Rajendra; Yadav, Prasad; Banpurkar, Arun; Ogale, Satishchandra; Gade, Wasudeo
2013-05-01
The resurgence of infectious diseases and associated issues related to antibiotic resistance has raised enormous challenges which may possibly be confronted primarily by nanotechnology routes. One key need of critical significance in this context is the development of an agent capable of inhibiting quorum sensing mediated biofilm formation in pathogenic organisms. In this work we examine the possible use of a nanocomposite, CdTe-TiO2, as an impeder of growth and biofilm. In the presence of CdTe-TiO2, scanning electron microscopy (SEM) analysis shows exposed cells without the surrounding matrix. Confocal laser scanning microscopy shows spatially distributed fluorescence, a typical indication of an impeded biofilm, as opposed to the control which shows matrix-covered cells and continuous fluorescence, typical of biofilm formation. Quantitatively, the inhibition of biofilm was ˜57%. CdTe-TiO2 also exhibits good antibacterial properties against Gram positive and Gram negative organisms by virtue of the generation of reactive oxygen species inside the cells, reflected by a ruptured appearance in the SEM analysis.
DIELECTROPHORESIS-BASED MICROFLUIDIC SEPARATION AND DETECTION SYSTEMS
Yang, Jun; Vykoukal, Jody; Noshari, Jamileh; Becker, Frederick; Gascoyne, Peter; Krulevitch, Peter; Fuller, Chris; Ackler, Harold; Hamilton, Julie; Boser, Bernhard; Eldredge, Adam; Hitchens, Duncan; Andrews, Craig
2009-01-01
Diagnosis and treatment of human diseases frequently requires isolation and detection of certain cell types from a complex mixture. Compared with traditional separation and detection techniques, microfluidic approaches promise to yield easy-to-use diagnostic instruments tolerant of a wide range of operating environments and capable of accomplishing automated analyses. These approaches will enable diagnostic advances to be disseminated from sophisticated clinical laboratories to the point-of-care. Applications will include the separation and differential analysis of blood cell subpopulations for host-based detection of blood cell changes caused by disease, infection, or exposure to toxins, and the separation and analysis of surface-sensitized, custom dielectric beads for chemical, biological, and biomolecular targets. Here we report a new particle separation and analysis microsystem that uses dielectrophoretic field-flow fractionation (DEP-FFF). The system consists of a microfluidic chip with integrated sample injector, a DEP-FFF separator, and an AC impedance sensor. We show the design of a miniaturized impedance sensor integrated circuit (IC) with improved sensitivity, a new packaging approach for micro-flumes that features a slide-together compression package and novel microfluidic interconnects, and the design, control, integration and packaging of a fieldable prototype. Illustrative applications will be shown, including the separation of different sized beads and different cell types, blood cell differential analysis, and impedance sensing results for beads, spores and cells. PMID:22025905
NASA Astrophysics Data System (ADS)
Hashim, Mohd.; Raghasudha, M.; Meena, Sher Singh; Shah, Jyoti; Shirsath, Sagar E.; Kumar, Shalendra; Ravinder, D.; Bhatt, Pramod; Alimuddin; Kumar, Ravi; Kotnala, R. K.
2018-03-01
Ce and Dy substituted Cobalt ferrites with the chemical composition CoCexDyxFe2-2xO4 (x = 0, 0.01, 0.02, 0.03, 0.04, 0.05) were synthesized through the chemical route, citrate-gel auto-combustion method. The structural characterization was carried out with the help of XRD Rieveld analysis, SEM and EDAX analysis. Formation of spinel cubic structure of the ferrites was confirmed by XRD analysis. SEM and EDAX results show that the particles are homogeneous with slight agglomeration without any impurity pickup. The effect of RE ion doping (Ce and Dy) on the dielectric, magnetic and impedance studies was systematically investigated by LCR meter, Vibrating Sample Magnetometer and Impedance analyzer respectively at room temperature in the frequency range of 10 Hz-10 MHz. Various dielectric parameters viz., dielectric constant, dielectric loss and ac conductivity were measured. The dielectric constant of all the ferrite compositions shows normal dielectric dispersion of ferrites with frequency. Impedance analysis confirms that the conduction in present ferrites is majorly due to the grain boundary mechanism. Ferrite sample with x = 0.03 show high dielectric constant, low dielectric loss and hence can be utilized in high frequency electromagnetic devices. Magnetization measurements indicate that with increase in Ce and Dy content in cobalt ferrites, the magnetization values decreased and coercivity has increased.
Chromosomal integration of adenoviral vector DNA in vivo.
Stephen, Sam Laurel; Montini, Eugenio; Sivanandam, Vijayshankar Ganesh; Al-Dhalimy, Muhseen; Kestler, Hans A; Finegold, Milton; Grompe, Markus; Kochanek, Stefan
2010-10-01
So far there has been no report of any clinical or preclinical evidence for chromosomal vector integration following adenovirus (Ad) vector-mediated gene transfer in vivo. We used liver gene transfer with high-capacity Ad vectors in the FAH(Deltaexon5) mouse model to analyze homologous and heterologous recombination events between vector and chromosomal DNA. Intravenous injection of Ad vectors either expressing a fumarylacetoacetate hydrolase (FAH) cDNA or carrying part of the FAH genomic locus resulted in liver nodules of FAH-expressing hepatocytes, demonstrating chromosomal vector integration. Analysis of junctions between vector and chromosomal DNA following heterologous recombination indicated integration of the vector genome through its termini. Heterologous recombination occurred with a median frequency of 6.72 x 10(-5) per transduced hepatocyte, while homologous recombination occurred more rarely with a median frequency of 3.88 x 10(-7). This study has established quantitative and qualitative data on recombination of adenoviral vector DNA with genomic DNA in vivo, contributing to a risk-benefit assessment of the biosafety of Ad vector-mediated gene transfer.
Mathematical Methods for Optical Physics and Engineering
NASA Astrophysics Data System (ADS)
Gbur, Gregory J.
2011-01-01
1. Vector algebra; 2. Vector calculus; 3. Vector calculus in curvilinear coordinate systems; 4. Matrices and linear algebra; 5. Advanced matrix techniques and tensors; 6. Distributions; 7. Infinite series; 8. Fourier series; 9. Complex analysis; 10. Advanced complex analysis; 11. Fourier transforms; 12. Other integral transforms; 13. Discrete transforms; 14. Ordinary differential equations; 15. Partial differential equations; 16. Bessel functions; 17. Legendre functions and spherical harmonics; 18. Orthogonal functions; 19. Green's functions; 20. The calculus of variations; 21. Asymptotic techniques; Appendices; References; Index.
Jung, Inuk; Jo, Kyuri; Kang, Hyejin; Ahn, Hongryul; Yu, Youngjae; Kim, Sun
2017-12-01
Identifying biologically meaningful gene expression patterns from time series gene expression data is important to understand the underlying biological mechanisms. To identify significantly perturbed gene sets between different phenotypes, analysis of time series transcriptome data requires consideration of time and sample dimensions. Thus, the analysis of such time series data seeks to search gene sets that exhibit similar or different expression patterns between two or more sample conditions, constituting the three-dimensional data, i.e. gene-time-condition. Computational complexity for analyzing such data is very high, compared to the already difficult NP-hard two dimensional biclustering algorithms. Because of this challenge, traditional time series clustering algorithms are designed to capture co-expressed genes with similar expression pattern in two sample conditions. We present a triclustering algorithm, TimesVector, specifically designed for clustering three-dimensional time series data to capture distinctively similar or different gene expression patterns between two or more sample conditions. TimesVector identifies clusters with distinctive expression patterns in three steps: (i) dimension reduction and clustering of time-condition concatenated vectors, (ii) post-processing clusters for detecting similar and distinct expression patterns and (iii) rescuing genes from unclassified clusters. Using four sets of time series gene expression data, generated by both microarray and high throughput sequencing platforms, we demonstrated that TimesVector successfully detected biologically meaningful clusters of high quality. TimesVector improved the clustering quality compared to existing triclustering tools and only TimesVector detected clusters with differential expression patterns across conditions successfully. The TimesVector software is available at http://biohealth.snu.ac.kr/software/TimesVector/. sunkim.bioinfo@snu.ac.kr. Supplementary data are available at Bioinformatics online. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com
NASA Astrophysics Data System (ADS)
Hus, Jean-Christophe; Bruschweiler, Rafael
2002-07-01
A general method is presented for the reconstruction of interatomic vector orientations from nuclear magnetic resonance (NMR) spectroscopic data of tensor interactions of rank 2, such as dipolar coupling and chemical shielding anisotropy interactions, in solids and partially aligned liquid-state systems. The method, called PRIMA, is based on a principal component analysis of the covariance matrix of the NMR parameters collected for multiple alignments. The five nonzero eigenvalues and their eigenvectors efficiently allow the approximate reconstruction of the vector orientations of the underlying interactions. The method is demonstrated for an isotropic distribution of sample orientations as well as for finite sets of orientations and internuclear vectors encountered in protein systems.
pYEMF, a pUC18-derived XcmI T-vector for efficient cloning of PCR products.
Gu, Jingsong; Ye, Chunjiang
2011-03-01
A 1330-bp DNA sequence with two XcmI cassettes was inserted into pUC18 to construct an efficient XcmI T-vector parent plasmid, pYEMF. The large size of the inserted DNA fragment improved T-vector cleavage efficiency, and guaranteed good separation of the molecular components after restriction digestion. The pYEMF-T-vector generated from parent plasmid pYEMF permits blue/white colony screening; cloning efficiency analysis showed that most white colonies (>75%) were putative transformants which carried the cloning product. The sequence analysis and design approach presented here will facilitate applications in the fields of molecular biology and genetic engineering.
Smart roadside initiative gap analysis : target functionality and gap analysis.
DOT National Transportation Integrated Search
2015-02-01
This document summarizes the target functionality for the Smart Roadside Initiative, as well as the operational, institutional, and technical gaps that currently impede the deployment of three of its operational scenarios (electronic mainline s...
A general numerical analysis program for the superconducting quasiparticle mixer
NASA Technical Reports Server (NTRS)
Hicks, R. G.; Feldman, M. J.; Kerr, A. R.
1986-01-01
A user-oriented computer program SISCAP (SIS Computer Analysis Program) for analyzing SIS mixers is described. The program allows arbitrary impedance terminations to be specified at all LO harmonics and sideband frequencies. It is therefore able to treat a much more general class of SIS mixers than the widely used three-frequency analysis, for which the harmonics are assumed to be short-circuited. An additional program, GETCHI, provides the necessary input data to program SISCAP. The SISCAP program performs a nonlinear analysis to determine the SIS junction voltage waveform produced by the local oscillator. The quantum theory of mixing is used in its most general form, treating the large signal properties of the mixer in the time domain. A small signal linear analysis is then used to find the conversion loss and port impedances. The noise analysis includes thermal noise from the termination resistances and shot noise from the periodic LO current. Quantum noise is not considered. Many aspects of the program have been adequately verified and found accurate.
Kalaiselvi, P; Raj, S Alfred Cecil; Jagannathan, K; Vijayan, N; Bhagavannarayana, G; Kalainathan, S
2014-11-11
Nonlinear optical single crystal of L-Proline trichloroacetate (L-PTCA) was successfully grown by Slow Evaporation Solution Technique (SEST). The grown crystals were subjected to single crystal X-ray diffraction analysis to confirm the structure. From the single crystal XRD data, solid state parameters were determined for the grown crystal. The crystalline perfection has been evaluated using high resolution X-ray diffractometer. The frequencies of various functional groups were identified from FTIR spectral analysis. The percentage of transmittance was obtained from UV Visible spectral analysis. TGA-DSC measurements indicate the thermal stability of the crystal. The dielectric constant, dielectric loss and ac conductivity were measured by the impedance analyzer. The DC conductivity was calculated by the cole-cole plot method. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Bykhovskiy, E. B.; Smirnov, N. V.
1983-01-01
The Hilbert space L2(omega) of vector functions is studied. A breakdown of L2(omega) into orthogonal subspaces is discussed and the properties of the operators for projection onto these subspaces are investigated from the standpoint of preserving the differential properties of the vectors being projected. Finally, the properties of the operators are examined.
Particle-In-Cell Simulations on Electric Field Antenna Characteristics in the Spacecraft Environment
NASA Astrophysics Data System (ADS)
Miyake, Y.; Usui, H.; Kojima, H.; Omura, Y.; Matsumoto, H.
2006-12-01
The Solar Terrestrial Physics (STP) group in Japan has organized a new magnetospheric mission named SCOPE whose objective is to investigate the scale-coupling process of plasma dynamics in the Terrestrial magnetosphere. For the sophisticated electric field measurements planned in the SCOPE mission, we have to investigate the antenna characteristics which are essential for the precise calibration of observed data. Particularly, (1) realistic antenna geometries including spacecraft body and (2) inhomogeneous plasma environment created by plasma-spacecraft interactions should be taken into consideration in the antenna analysis for application to the scientific mission. However, the analysis of the antenna impedance is very complex because the plasma is a dispersive and anisotropic medium, and thus it is too difficult to consider the realistic plasma environment near the spacecraft by the theoretical approaches. In the present study, we apply the Particle-In-Cell simulations to the antenna analysis, which enables us to treat the antenna model including a spacecraft body and analyze the effects of photoelectron emission on antenna characteristics. The present antenna model consists of perfect conducting antennas and spacecraft body, and the photoelectron emission from the sunlit surfaces is also modeled. Using these models, we first performed the electrostatic simulations and examined the photoelectron environment around the spacecraft. Next, the antenna impedance under the obtained photoelectron environment was examined by the electromagnetic simulations. Impedance values obtained in photoelectron environment were much different from those in free space, and they were analogous to the impedance characteristics of an equivalent electric circuit consisting of a resistance and capacitance connected in parallel. The validity of the obtained values has been examined by the comparison with the measurements by the scientific spacecraft.
Development of AC impedance methods for evaluating corroding metal surfaces and coatings
NASA Technical Reports Server (NTRS)
Knockemus, Ward
1986-01-01
In an effort to investigate metal surface corrosion and the breakdown of metal protective coatings the AC Impedance Method was applied to zinc chromate primer coated 2219-T87 aluminum. The model 368-1 AC Impedance Measurement System recently acquired by the MSFC Corrosion Research Branch was used to monitor changing properties of coated aluminum disks immersed in 3.5% NaCl buffered at ph 5.5 over three to four weeks. The DC polarization resistance runs were performed on the same samples. The corrosion system can be represented by an electronic analog called an equivalent circuit that consists of transistors and capacitors in specific arrangements. This equivalent circuit parallels the impedance behavior of the corrosion system during a frequency scan. Values for resistances and capacities that can be assigned in the equivalent circuit following a least squares analysis of the data describe changes that occur on the corroding metal surface and in the protective coating. A suitable equivalent circuit was determined that predicts the correct Bode phase and magnitude for the experimental sample. The DC corrosion current density data are related to equivalent circuit element parameters.
Liang, Weihua; Liu, Yushan; Ge, Baoming; ...
2017-09-08
The battery energy stored quasi-Z-source (BESqZS) based photovoltaic (PV) power generation system combines advantages of the qZS inverter and the battery energy storage system. But, the second harmonic (2ω) power ripple degrades the system’s performance and affects the system’s design. An accurate model to analyze the 2ω ripple is very important. The existing models did not consider the battery, or assumed a symmetric qZS network with L 1=L 2 and C 1=C 2, which limits the design freedom and causes oversized impedance parameters. Our paper proposes a comprehensive model for the single-phase BES-qZS-PV inverter system, where the battery is consideredmore » and there is no restriction of L 1=L 2 and C 1=C 2. Based on the built model, a BES-qZS impedance design method is proposed to mitigate the 2ω ripple with asymmetric qZS network. Simulation and experimental results verify the proposed 2ω ripple model and impedance design method.« less
Electrical and absorption properties of fresh cassava tubers and cassava starch
NASA Astrophysics Data System (ADS)
Harnsoongnoen, S.; Siritaratiwat, A.
2015-09-01
The objective of this study was to analyze the electrical and absorption properties of fresh cassava tubers and cassava starch at various frequencies using electric impedance spectroscopy and near-infrared spectroscopy, as well as determine the classification of the electrical parameters of both materials using the principle component analysis (PCA) method. All samples were measured at room temperature. The electrical and absorption parameters consisted of dielectric constant, dissipation factor, parallel capacitance, resistance, reactance, impedance and absorbance. It was found that the electrical and absorption properties of fresh cassava tubers and cassava starch were a function of frequency, and there were significant differences between the materials. The dielectric constant, parallel capacitance, resistance and impedance of fresh cassava tubers and cassava starch had similar dramatic decreases with increasing frequency. However, the reactance of both materials increased with an increasing frequency. The electrical parameters of both materials could be classified into two groups. Moreover, the dissipation factor and phase of impedance were the parameters that could be used in the separation of both materials. According to the absorbance patterns of the fresh cassava tubers and cassava starch, there were significant differences.
Ito, Kazuyo; Yoshida, Kenji; Maruyama, Hitoshi; Mamou, Jonathan; Yamaguchi, Tadashi
2017-03-01
Acoustic properties of free fatty acids present in the liver were studied as a possible basis for non-invasive ultrasonic diagnosis of non-alcoholic steatohepatitis. Acoustic impedance was measured for the following types of tissue samples: Four pathologic types of mouse liver, five kinds of FFAs in solvent and five kinds of FFAs in cultured Huh-7 cells. A transducer with an 80-MHz center frequency was incorporated into a scanning acoustic microscopy system. Acoustic impedance was calculated from the amplitude of the signal reflected from the specimen surface. The Kruskal-Wallis test revealed statistically significant differences (p < 0.01) in acoustic impedance not only among pathologic types, but also among the FFAs in solvent and in cultured Huh-7 cells. These results suggest that each of the FFAs, especially palmitate, oleate and palmitoleate acid, can be distinguished from each other, regardless of whether they were in solution or absorbed by cells. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Performance analysis of ultrasono-therapy transducer with contact detection.
Moreno, Eduardo; González, Gilberto; Leija, Lorenzo; Rodríguez, Orlando; Castillo, Martha; Fuentes, Martín
2003-06-01
The performance of ultrasono-therapy transducer with contact detection by using the impedance phase change is described. Usually a therapy transducer is designed with a lambda/2 frontal plate glued to a PZT-4 piezoceramic. This plate ensures a good mechanical protection of the piezoceramic with a corresponding high-transmission energy. Normally this transducer is operated at the minimum at the frequency of the impedance module of its input electric impedance, but this operation point is affected by the shift caused by the expected temperature increase. This shift could be higher than the narrow bandwidth presented. As a result we obtain a decrease in the power level for medical treatment. Usually it is designed electronic drivers with automatic control that follow the frequency change, but the relatively narrow bandwidth introduces difficulty in the design. Another frequency operation point is presented here and analyzed using the criteria of the maximum of the impedance phase with a wider bandwidth than in the previous case. Simulation with mechanical losses are presented with experimental results that show the convenience of this criteria for practical application.
Advanced Nacelle Acoustic Lining Concepts Development
NASA Technical Reports Server (NTRS)
Bielak, G.; Gallman, J.; Kunze, R.; Murray, P.; Premo, J.; Kosanchick, M.; Hersh, A.; Celano, J.; Walker, B.; Yu, J.;
2002-01-01
The work reported in this document consisted of six distinct liner technology development subtasks: 1) Analysis of Model Scale ADP Fan Duct Lining Data (Boeing): An evaluation of an AST Milestone experiment to demonstrate 1995 liner technology superiority relative to that of 1992 was performed on 1:5.9 scale model fan rig (Advanced Ducted Propeller) test data acquired in the NASA Glenn 9 x 15 foot wind tunnel. The goal of 50% improvement was deemed satisfied. 2) Bias Flow Liner Investigation (Boeing, VCES): The ability to control liner impedance by low velocity bias flow through liner was demonstrated. An impedance prediction model to include bias flow was developed. 3) Grazing Flow Impedance Testing (Boeing): Grazing flow impedance tests were conducted for comparison with results achieved at four different laboratories. 4) Micro-Perforate Acoustic Liner Technology (BFG, HAE, NG): Proof of concept testing of a "linear liner." 5) Extended Reaction Liners (Boeing, NG): Bandwidth improvements for non-locally reacting liner were investigated with porous honeycomb core test liners. 6) Development of a Hybrid Active/Passive Lining Concept (HAE): Synergism between active and passive attenuation of noise radiated by a model inlet was demonstrated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liang, Weihua; Liu, Yushan; Ge, Baoming
The battery energy stored quasi-Z-source (BESqZS) based photovoltaic (PV) power generation system combines advantages of the qZS inverter and the battery energy storage system. But, the second harmonic (2ω) power ripple degrades the system’s performance and affects the system’s design. An accurate model to analyze the 2ω ripple is very important. The existing models did not consider the battery, or assumed a symmetric qZS network with L 1=L 2 and C 1=C 2, which limits the design freedom and causes oversized impedance parameters. Our paper proposes a comprehensive model for the single-phase BES-qZS-PV inverter system, where the battery is consideredmore » and there is no restriction of L 1=L 2 and C 1=C 2. Based on the built model, a BES-qZS impedance design method is proposed to mitigate the 2ω ripple with asymmetric qZS network. Simulation and experimental results verify the proposed 2ω ripple model and impedance design method.« less
Hu, Ning; Fang, Jiaru; Zou, Ling; Wan, Hao; Pan, Yuxiang; Su, Kaiqi; Zhang, Xi; Wang, Ping
2016-10-01
Cell-based bioassays were effective method to assess the compound toxicity by cell viability, and the traditional label-based methods missed much information of cell growth due to endpoint detection, while the higher throughputs were demanded to obtain dynamic information. Cell-based biosensor methods can dynamically and continuously monitor with cell viability, however, the dynamic information was often ignored or seldom utilized in the toxin and drug assessment. Here, we reported a high-efficient and high-content cytotoxic recording method via dynamic and continuous cell-based impedance biosensor technology. The dynamic cell viability, inhibition ratio and growth rate were derived from the dynamic response curves from the cell-based impedance biosensor. The results showed that the biosensors has the dose-dependent manners to diarrhetic shellfish toxin, okadiac acid based on the analysis of the dynamic cell viability and cell growth status. Moreover, the throughputs of dynamic cytotoxicity were compared between cell-based biosensor methods and label-based endpoint methods. This cell-based impedance biosensor can provide a flexible, cost and label-efficient platform of cell viability assessment in the shellfish toxin screening fields.
[Current status of noninvasive hemodynamics in hypertension].
Waisman, G
Hypertension is a haemodynamic disorder resulting from a persistent mismatch between cardiac output and peripheral resistance. Hypertension undergoes haemodynamic progression during its natural history. Impedance cardiography is a method of evaluating the cardiovascular system that obtains haemodynamic information from beat to beat through the analysis of variations in the impedance of the thorax on the passage of an electric current. Impedance cardiography unmasks the haemodynamic deterioration underlying the increase in blood pressure as age and systolic blood pressure increases. This method may help to improve blood pressure control through individualized treatment with reduction of peripheral resistance, maintenance of cardiac output or its increase, improvement of arterial compliance and preservation of organ-tissue perfusion. It is useful in the management of patients with resistant hypertension, since a greater percentage of patients controlled with changes in the treatment in relation to the haemodynamic measurements are obtained. Impedance cardiography is important and has prognostic utility in relation to a haemodynamic deterioration pattern and increased cardiovascular events. Copyright © 2017 SEH-LELHA. Publicado por Elsevier España, S.L.U. All rights reserved.
The IMPACT shirt: textile integrated and portable impedance cardiography.
Ulbrich, Mark; Mühlsteff, Jens; Sipilä, Auli; Kamppi, Merja; Koskela, Anne; Myry, Manu; Wan, Tingting; Leonhardt, Steffen; Walter, Marian
2014-06-01
Measurement of hemodynamic parameters such as stroke volume (SV) via impedance cardiography (ICG) is an easy, non-invasive and inexpensive way to assess the health status of the heart. We present a possibility to use this technology for monitoring risk patients at home. The IMPACT Shirt (IMPedAnce Cardiography Textile) has been developed with integrated textile electrodes and textile wiring, as well as with portable miniaturized hardware. Several textile materials were characterized in vitro and in vivo to analyze their performance with regard to washability, and electrical characteristics such as skin-electrode impedance, capacitive coupling and subjective tactile feeling. The small lightweight hardware measures ECG and ICG continuously and transmits wireless data via Bluetooth to a mobile phone (Android) or PC for further analysis. A lithium polymer battery supplies the circuit and can be charged via a micro-USB. Results of a proof-of-concept trial show excellent agreement between SV assessed by a commercial device and the developed system. The IMPACT Shirt allows monitoring of SV and ECG on a daily basis at the patient's home.
NASA Astrophysics Data System (ADS)
Min, Jiyoung; Shim, Hyojin; Yun, Chung-Bang
2012-04-01
For a nuclear containment structure, the structural health monitoring is essential because of its high potential risk and grave social impact. In particular, the tendon and anchorage zone are to be monitored because they are under high tensile or compressive stress. In this paper, a method to monitor the tendon force and the condition of the anchorage zone is presented by using the impedance-based health diagnosis system. First, numerical simulations were conducted for cases with various loose tensile forces on the tendon as well as damages on the bearing plate and concrete structure. Then, experimental studies were carried out on a scaled model of the anchorage system. The relationship between the loose tensile force and the impedance-based damage index was analyzed by a regression analysis. When a structure gets damaged, the damage index increases so that the status of damage can be identified. The results of the numerical and experimental studies indicate a big potential of the proposed impedance-based method for monitoring the tendon and anchorage system.
Impedimetric method for measuring ultra-low E. coli concentrations in human urine.
Settu, Kalpana; Chen, Ching-Jung; Liu, Jen-Tsai; Chen, Chien-Lung; Tsai, Jang-Zern
2015-04-15
In this study, we developed an interdigitated gold microelectrode-based impedance sensor to detect Escherichia coli (E. coli) in human urine samples for urinary tract infection (UTI) diagnosis. E. coli growth in human urine samples was successfully monitored during a 12-h culture, and the results showed that the maximum relative changes could be measured at 10Hz. An equivalent electrical circuit model was used for evaluating the variations in impedance characteristics of bacterial growth. The equivalent circuit analysis indicated that the change in impedance values at low frequencies was caused by double layer capacitance due to bacterial attachment and formation of biofilm on electrode surface in urine. A linear relationship between the impedance change and initial E. coli concentration was obtained with the coefficient of determination R(2)>0.90 at various growth times of 1, 3, 5, 7, 9 and 12h in urine. Thus our sensor is capable of detecting a wide range of E. coli concentration, 7×10(0) to 7×10(8) cells/ml, in urine samples with high sensitivity. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Dey, Arka; Dhar, Joydeep; Sil, Sayantan; Jana, Rajkumar; Ray, Partha Pratim
2018-04-01
In this report, bias voltage-dependent dielectric and electron transport properties of ZnS nanoparticles were discussed. ZnS nanoparticles were synthesized by introducing a modified hydrothermal process. The powder XRD pattern indicates the phase purity, and field emission scanning electron microscope image demonstrates the morphology of the synthesized sample. The optical band gap energy (E g = 4.2 eV) from UV measurement explores semiconductor behavior of the synthesized material. The electrical properties were performed at room temperature using complex impedance spectroscopy (CIS) technique as a function of frequency (40 Hz-10 MHz) under different forward dc bias voltages (0-1 V). The CIS analysis demonstrates the contribution of bulk resistance in conduction mechanism and its dependency on forward dc bias voltages. The imaginary part of the impedance versus frequency curve exhibits the existence of relaxation peak which shifts with increasing dc forward bias voltages. The dc bias voltage-dependent ac and dc conductivity of the synthesized ZnS was studied on thin film structure. A possible hopping mechanism for electrical transport processes in the system was investigated. Finally, it is worth to mention that this analysis of bias voltage-dependent dielectric and transport properties of as-synthesized ZnS showed excellent properties for emerging energy applications.
Ayas, Selçuk; Bayraktar, Mesut; Gürbüz, Ayşe; Alkan, Akif; Eren, Sadiye
2012-01-01
Objective: We aimed to evaluate uterine junctional zone thickness, cervical length and bioelectrical impedance analysis of body composition in women with endometriosis. Material and Methods: This is a prospective study conducted in a tertiary teaching hospital. A total of 73 patients were included in the study. Endometriosis was surgically diagnosed in 36 patients (study group). The control group included 37 patients. Main outcome measure(s): Bioelectrical impedance analysis was used to measure body composition. Uterine junctional zone thickness and cervical length were measured by transvaginal ultrasonography. Results: Patients’ characteristics (age, gravida, parity, live baby, age of menarche, lengths of menstrual cycle, percentage of patients with dysmenorrhea, positive family history), body mass index (BMI) (kg/m2), amount of body fat (kg), percentage of body fat were not statistically different between the two groups (p>0.05). The length of menstruation and cervical length were longer in women with endometriosis. Similarly, the inner myometrium was thicker in women with endometriosis than the control group. Conclusion: The relation between endometriosis and demographic features such as age, gravida, parity, gravida, BMI, lengths of the menstrual cycle, age of menarche are controversial. Longer cervical length and thicker inner myometrial layer may be important in the etiopathogenesis of endometriosis. PMID:25207044
The influence of image reconstruction algorithms on linear thorax EIT image analysis of ventilation.
Zhao, Zhanqi; Frerichs, Inéz; Pulletz, Sven; Müller-Lisse, Ullrich; Möller, Knut
2014-06-01
Analysis methods of electrical impedance tomography (EIT) images based on different reconstruction algorithms were examined. EIT measurements were performed on eight mechanically ventilated patients with acute respiratory distress syndrome. A maneuver with step increase of airway pressure was performed. EIT raw data were reconstructed offline with (1) filtered back-projection (BP); (2) the Dräger algorithm based on linearized Newton-Raphson (DR); (3) the GREIT (Graz consensus reconstruction algorithm for EIT) reconstruction algorithm with a circular forward model (GR(C)) and (4) GREIT with individual thorax geometry (GR(T)). Individual thorax contours were automatically determined from the routine computed tomography images. Five indices were calculated on the resulting EIT images respectively: (a) the ratio between tidal and deep inflation impedance changes; (b) tidal impedance changes in the right and left lungs; (c) center of gravity; (d) the global inhomogeneity index and (e) ventilation delay at mid-dorsal regions. No significant differences were found in all examined indices among the four reconstruction algorithms (p > 0.2, Kruskal-Wallis test). The examined algorithms used for EIT image reconstruction do not influence the selected indices derived from the EIT image analysis. Indices that validated for images with one reconstruction algorithm are also valid for other reconstruction algorithms.
Predicting fat-free mass in children using bioimpedance analysis.
Pietrobelli, A; Andreoli, A; Cervelli, V; Carbonelli, M G; Peroni, D G; De Lorenzo, A
2003-10-01
Body composition assessment is a useful procedure for the study of nutritional status and water distribution. In adults, it is a predictor of morbidity and mortality, since body fatness is associated with risk factors for cardiovascular disease. Bioelectric impedance analysis (BIA) is a simple, safe, and inexpensive method for assessment of body composition both in pediatric and adult subjects. The aim of our study was to validate the impedance index, ZI (H(2)/Z, height in cm(2)/impedance), as a predictor factor of fatfree mass (FFM) and fat mass (FM) in a sample ( n=75) of normal children. Dual-energy X-ray absorptiometry (DXA) was chosen as reference method. Despite some minor bias, DXAis considerably less expensive and easier to administer in pediatric subjects than other established gold standard reference methods for assessing body composition. ZI values were highly correlated with FFM measured with DXA. The following equations were obtained from the regression analysis: (a). male subjects, FFM(DXA)=0.6375 (ZI)+5.9913, r(2)=0.897, p<0.0001; (b). female subjects, FFM(DXA)=0.7597 (ZI)+ 3.5853, r(2)=0.903, p<0.0001. These data support the notion that BIA alone can be used as a surrogate to measure FFM in a pediatric sample.
Hermann-Bernoulli-Laplace-Hamilton-Runge-Lenz Vector.
ERIC Educational Resources Information Center
Subramanian, P. R.; And Others
1991-01-01
A way for students to refresh and use their knowledge in both mathematics and physics is presented. By the study of the properties of the "Runge-Lenz" vector the subjects of algebra, analytical geometry, calculus, classical mechanics, differential equations, matrices, quantum mechanics, trigonometry, and vector analysis can be reviewed. (KR)
NASA Technical Reports Server (NTRS)
Anderson, Karl F. (Inventor)
1994-01-01
A constant current loop measuring system is provided for measuring a characteristic of an environment. The system comprises a first impedance positionable in the environment, a second impedance coupled in series with said first impedance and a parasitic impedance electrically coupled to the first and second impedances. A current generating device, electrically coupled in series with the first and second impedances, provides a constant current through the first and second impedances to produce first and second voltages across the first and second impedances, respectively, and a parasitic voltage across the parasitic impedance. A high impedance voltage measuring device measures a voltage difference between the first and second voltages independent of the parasitic voltage to produce a characteristic voltage representative of the characteristic of the environment.
Damage detection of civil infrastructures with piezoelectric oscillator sensors
NASA Astrophysics Data System (ADS)
Roh, Y. R.; Kim, D. Y.; Park, S. H.; Yun, C. B.
2006-03-01
Many researches have been reported on the condition monitoring of civil infrastructures by means of piezoelectric sensors. Most of them made use of the impedance change of the piezoelectric device in relation to the creation of internal damages to the structure. The impedance measurement is a well accepted method in the piezoelectric sensor area, and has been proved by many authors to be useful for civil structure diagnosis. However, the impedance measurement normally requires sophisticated equipment and analysis technology. For more general and wide application of the piezoelectric diagnosis tool, a new methodology is desired to overcome the limitations of the impedance measurement. This paper presents the feasibility of a piezoelectric oscillator sensor to detect the damages in civil infrastructures. The oscillator sensor is composed of an electronic feedback oscillator circuit and a piezoelectric thickness mode vibrator to be attached to the structure of interest. Damage to the structure causes a change in the impedance spectrum of the structure, which results in a corresponding change of the resonant frequency of the structure. The oscillator sensors can instantly detect the frequency change in a very simple manner. Feasibility of the piezoelectric oscillator sensor was verified in this work with a sample aluminum plate where artificial cracks of different depth were imposed in sequence. Validity of the measurement was confirmed through comparison of the experimental data with the results of finite element analyses of the plate with cracks. Performance of the oscillator sensor was also compared with that of its conventional counterpart, i.e. impedance measurement, to manifest the superiority of the oscillator sensor.
Chen, Shing-Jye; Gielo-Perczak, Krystyna
2011-01-01
Arch supports commonly used to alleviate foot pain can impede the normal drop of medial longitudinal arch (MLA) thereby altering its function. The purpose of the study was to examine the effect of using arch supports on vertical ground reaction force (GRF) and center of pressure (COP) during simulated midstance while the foot was statically loaded. Ten healthy young subjects were recruited. Two dimensional (2D) analysis of the MLA was captured for both barefoot (BF) and arch support conditions before and after loading via a custom made weight loading apparatus. The foot was loaded and positioned to simulate the midstance phase of walking. Two-dimensional reflective markers demarcated the MLA and captured with the loaded foot on a force platform. The impeded MLA drop was compared between the unloaded BF, loaded BF and loaded arch support conditions. The vertical GRF, the anterior-posterior and the medial-lateral COP displacements were also measured in response to the impeded MLA by the arch supports. The arch supports impeded the MLA drop (p<0.05) and shifted the COP toward the medial side (p<0.05), specifically for the rearfoot (calcaneal segment region), but no changes were determined for the vertical GRF (p>0.05). The impedance of MLA drop by the arch support altered the pattern of the ML COP shift in the rearfoot region. The use of arch supports may not relieve painful foot conditions that are associated with excessive calcaneal eversion indicated by altering COP shifts in localized foot regions.
Impedance changes during setting of amorphous calcium phosphate composites.
Par, Matej; Šantić, Ana; Gamulin, Ozren; Marovic, Danijela; Moguš-Milanković, Andrea; Tarle, Zrinka
2016-11-01
To investigate the electrical properties of experimental light-curable composite materials based on amorphous calcium phosphate (ACP) with the admixture of silanized barium glass and silica fillers. Short-term setting was investigated by impedance measurements at a frequency of 1kHz, while for the long-term setting the impedance spectra were measured consecutively over a frequency range of 0.05Hz to 1MHz for 24h. The analysis of electrical resistivity changes during curing allowed the extraction of relevant kinetic parameters. The impedance results were correlated to the degree of conversion assessed by Raman spectroscopy, water content determined by gravimetry, light transmittance measured by CCD spectrometer and microstructural features observed by scanning electron microscopy. ACP-based composites have shown higher immediate degree of conversion and less post-cure polymerization than the control composites, but lower polymerization rate. The polymerization rate assessed by impedance measurements correlated well with the light transmittance. The differences in the electrical conductivity values observed among the materials were correlated to the amount of water introduced into composites by the ACP filler. High correlation was found between the degree of conversion and electrical resistivity. Equivalent circuit modeling revealed two electrical contributions for the ACP-based composites and a single contribution for the control composites. The impedance spectroscopy has proven a valuable method for gaining insight into various features of ACP-based composites. Better understanding of the properties of ACP-based composites should further the development of these promising bioactive materials. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Vanderheyden, Yoachim; Cabooter, Deirdre; Desmet, Gert; Broeckhoven, Ken
2013-10-18
The intrinsic kinetic performance of three recently commercialized large size (≥4μm) core-shell particles packed in columns with different lengths has been measured and compared with that of standard fully porous particles of similar and smaller size (5 and 3.5μm, respectively). The kinetic performance is compared in both absolute (plot of t0 versus the plate count N or the peak capacity np for isocratic and gradient elution, respectively) and dimensionless units. The latter is realized by switching to so-called impedance plots, a format which has been previously introduced (as a plot of t0/N(2) or E0 versus Nopt/N) and has in the present study been extended from isocratic to gradient elution (where the impedance plot corresponds to a plot of t0/np(4) versus np,opt(2)/np(2)). Both the isocratic and gradient impedance plot yielded a very similar picture: the clustered impedance plot curves divide into two distinct groups, one for the core-shell particles (lowest values, i.e. best performance) and one for the fully porous particles (highest values), confirming the clear intrinsic kinetic advantage of core-shell particles. If used around their optimal flow rate, the core-shell particles displayed a minimal separation impedance that is about 40% lower than the fully porous particles. Even larger gains in separation speed can be achieved in the C-term regime. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Shinnaka, Shinji
This paper presents a new unified analysis of estimate errors by model-matching extended-back-EMF estimation methods for sensorless drive of permanent-magnet synchronous motors. Analytical solutions about estimate errors, whose validity is confirmed by numerical experiments, are rich in universality and applicability. As an example of universality and applicability, a new trajectory-oriented vector control method is proposed, which can realize directly quasi-optimal strategy minimizing total losses with no additional computational loads by simply orienting one of vector-control coordinates to the associated quasi-optimal trajectory. The coordinate orientation rule, which is analytically derived, is surprisingly simple. Consequently the trajectory-oriented vector control method can be applied to a number of conventional vector control systems using model-matching extended-back-EMF estimation methods.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allen, L.N.; Hanson, R.S.
Four new cloning vectors have been constructed from the broad-host-range cloning vector pRK290. These vectors, pLA2901, pLA2905, pLA2910, and pLA2917, confer resistance to kanamycin and tetracycline. The latter two are cosmid derivatives of pLA2901. The new vectors can be mobilized into, and are stably maintained in, a variety of gram-negative bacteria. A Sau3A genomic bank of Methylobacterium organophilum strain xx DNA has been constructed in pLA2917, and complementation analysis, with a variety of mutants unable to grow on methanol, revealed at least five separate regions necessary for growth on methanol. Complementation analysis and Tn5 mutagenesis data suggest that at leastmore » three genes are responsible for expression of active methanol dehydrogenase.« less
Analysis of structural response data using discrete modal filters. M.S. Thesis
NASA Technical Reports Server (NTRS)
Freudinger, Lawrence C.
1991-01-01
The application of reciprocal modal vectors to the analysis of structural response data is described. Reciprocal modal vectors are constructed using an existing experimental modal model and an existing frequency response matrix of a structure, and can be assembled into a matrix that effectively transforms the data from the physical space to a modal space within a particular frequency range. In other words, the weighting matrix necessary for modal vector orthogonality (typically the mass matrix) is contained within the reciprocal model matrix. The underlying goal of this work is mostly directed toward observing the modal state responses in the presence of unknown, possibly closed loop forcing functions, thus having an impact on both operating data analysis techniques and independent modal space control techniques. This study investigates the behavior of reciprocol modal vectors as modal filters with respect to certain calculation parameters and their performance with perturbed system frequency response data.
Application of optical correlation techniques to particle imaging velocimetry
NASA Technical Reports Server (NTRS)
Wernet, Mark P.; Edwards, Robert V.
1988-01-01
Pulsed laser sheet velocimetry yields nonintrusive measurements of velocity vectors across an extended 2-dimensional region of the flow field. The application of optical correlation techniques to the analysis of multiple exposure laser light sheet photographs can reduce and/or simplify the data reduction time and hardware. Here, Matched Spatial Filters (MSF) are used in a pattern recognition system. Usually MSFs are used to identify the assembly line parts. In this application, the MSFs are used to identify the iso-velocity vector contours in the flow. The patterns to be recognized are the recorded particle images in a pulsed laser light sheet photograph. Measurement of the direction of the partical image displacements between exposures yields the velocity vector. The particle image exposure sequence is designed such that the velocity vector direction is determined unambiguously. A global analysis technique is used in comparison to the more common particle tracking algorithms and Young's fringe analysis technique.
Alphavirus replicon approach to promoterless analysis of IRES elements.
Kamrud, K I; Custer, M; Dudek, J M; Owens, G; Alterson, K D; Lee, J S; Groebner, J L; Smith, J F
2007-04-10
Here we describe a system for promoterless analysis of putative internal ribosome entry site (IRES) elements using an alphavirus (family Togaviridae) replicon vector. The system uses the alphavirus subgenomic promoter to produce transcripts that, when modified to contain a spacer region upstream of an IRES element, allow analysis of cap-independent translation of genes of interest (GOI). If the IRES element is removed, translation of the subgenomic transcript can be reduced >95% compared to the same transcript containing a functional IRES element. Alphavirus replicons, used in this manner, offer an alternative to standard dicistronic DNA vectors or in vitro translation systems currently used to analyze putative IRES elements. In addition, protein expression levels varied depending on the spacer element located upstream of each IRES. The ability to modulate the level of expression from alphavirus vectors should extend the utility of these vectors in vaccine development.
Alphavirus Replicon Approach to Promoterless Analysis of IRES Elements
Kamrud, K.I.; Custer, M.; Dudek, J.M.; Owens, G.; Alterson, K.D.; Lee, J.S.; Groebner, J.L.; Smith, J.F.
2007-01-01
Here we describe a system for promoterless analysis of putative internal ribosome entry site (IRES) elements using an alphavirus (Family Togaviridae) replicon vector. The system uses the alphavirus subgenomic promoter to produce transcripts that, when modified to contain a spacer region upstream of an IRES element, allow analysis of cap-independent translation of genes of interest (GOI). If the IRES element is removed, translation of the subgenomic transcript can be reduced > 95 % compared to the same transcript containing a functional IRES element. Alphavirus replicons, used in this manner, offer an alternative to standard dicistronic DNA vectors or in-vitro translation systems currently used to analyze putative IRES elements. In addition, protein expression levels varied depending on the spacer element located upstream of each IRES. The ability to modulate the level of expression from alphavirus vectors should extend the utility of these vectors in vaccine development. PMID:17156813
Weber, K; Mock, U; Petrowitz, B; Bartsch, U; Fehse, B
2010-04-01
Vector-encoded fluorescent proteins (FPs) facilitate unambiguous identification or sorting of gene-modified cells by fluorescence-activated cell sorting (FACS). Exploiting this feature, we have recently developed lentiviral gene ontology (LeGO) vectors (www.LentiGO-Vectors.de) for multi-gene analysis in different target cells. In this study, we extend the LeGO principle by introducing 10 different drug-selectable FPs created by fusing one of the five selection marker (protecting against blasticidin, hygromycin, neomycin, puromycin and zeocin) and one of the five FP genes (Cerulean, eGFP, Venus, dTomato and mCherry). All tested fusion proteins allowed both fluorescence-mediated detection and drug-mediated selection of LeGO-transduced cells. Newly generated codon-optimized hygromycin- and neomycin-resistance genes showed improved expression as compared with their ancestors. New LeGO constructs were produced at titers >10(6) per ml (for non-concentrated supernatants). We show efficient combinatorial marking and selection of various cells, including mesenchymal stem cells, simultaneously transduced with different LeGO constructs. Inclusion of the cytomegalovirus early enhancer/chicken beta-actin promoter into LeGO vectors facilitated robust transgene expression in and selection of neural stem cells and their differentiated progeny. We suppose that the new drug-selectable markers combining advantages of FACS and drug selection are well suited for numerous applications and vector systems. Their inclusion into LeGO vectors opens new possibilities for (stem) cell tracking and functional multi-gene analysis.
Vaxvec: The first web-based recombinant vaccine vector database and its data analysis.
Deng, Shunzhou; Martin, Carly; Patil, Rasika; Zhu, Felix; Zhao, Bin; Xiang, Zuoshuang; He, Yongqun
2015-11-27
A recombinant vector vaccine uses an attenuated virus, bacterium, or parasite as the carrier to express a heterologous antigen(s). Many recombinant vaccine vectors and related vaccines have been developed and extensively investigated. To compare and better understand recombinant vectors and vaccines, we have generated Vaxvec (http://www.violinet.org/vaxvec), the first web-based database that stores various recombinant vaccine vectors and those experimentally verified vaccines that use these vectors. Vaxvec has now included 59 vaccine vectors that have been used in 196 recombinant vector vaccines against 66 pathogens and cancers. These vectors are classified to 41 viral vectors, 15 bacterial vectors, 1 parasitic vector, and 1 fungal vector. The most commonly used viral vaccine vectors are double-stranded DNA viruses, including herpesviruses, adenoviruses, and poxviruses. For example, Vaxvec includes 63 poxvirus-based recombinant vaccines for over 20 pathogens and cancers. Vaxvec collects 30 recombinant vector influenza vaccines that use 17 recombinant vectors and were experimentally tested in 7 animal models. In addition, over 60 protective antigens used in recombinant vector vaccines are annotated and analyzed. User-friendly web-interfaces are available for querying various data in Vaxvec. To support data exchange, the information of vaccine vectors, vaccines, and related information is stored in the Vaccine Ontology (VO). Vaxvec is a timely and vital source of vaccine vector database and facilitates efficient vaccine vector research and development. Copyright © 2015 Elsevier Ltd. All rights reserved.
Kaldjian, Lauris C; Jones, Elizabeth W; Rosenthal, Gary E; Tripp-Reimer, Toni; Hillis, Stephen L
2006-01-01
BACKGROUND Physician disclosure of medical errors to institutions, patients, and colleagues is important for patient safety, patient care, and professional education. However, the variables that may facilitate or impede disclosure are diverse and lack conceptual organization. OBJECTIVE To develop an empirically derived, comprehensive taxonomy of factors that affects voluntary disclosure of errors by physicians. DESIGN A mixed-methods study using qualitative data collection (structured literature search and exploratory focus groups), quantitative data transformation (sorting and hierarchical cluster analysis), and validation procedures (confirmatory focus groups and expert review). RESULTS Full-text review of 316 articles identified 91 impeding or facilitating factors affecting physicians' willingness to disclose errors. Exploratory focus groups identified an additional 27 factors. Sorting and hierarchical cluster analysis organized factors into 8 domains. Confirmatory focus groups and expert review relocated 6 factors, removed 2 factors, and modified 4 domain names. The final taxonomy contained 4 domains of facilitating factors (responsibility to patient, responsibility to self, responsibility to profession, responsibility to community), and 4 domains of impeding factors (attitudinal barriers, uncertainties, helplessness, fears and anxieties). CONCLUSIONS A taxonomy of facilitating and impeding factors provides a conceptual framework for a complex field of variables that affects physicians' willingness to disclose errors to institutions, patients, and colleagues. This taxonomy can be used to guide the design of studies to measure the impact of different factors on disclosure, to assist in the design of error-reporting systems, and to inform educational interventions to promote the disclosure of errors to patients. PMID:16918739
NASA Astrophysics Data System (ADS)
Bellotti, Mariela I.; Giana, Fabián E.; Bonetto, Fabián J.
2015-08-01
Electrical wound-healing assays are often used as a means to study in vitro cell migration and proliferation. In such analysis, a cell monolayer that sits on a small electrode is electrically wounded and its spectral impedance is then continuously measured in order to monitor the healing process. The relatively slow dynamics of the cell healing have been extensively studied, while those of the much faster wounding phase have not yet been investigated. An analysis of the electrical properties of a particular cell type during this phase could give extra information about the changes in the cell membrane due to the application of the wounding current, and could also be useful to optimize the wounding regime for different cell types. The main issue when trying to register information about these dynamics is that the traditional measurement scheme employed in typical wound-healing assays doesn’t allow the simultaneous application of the wounding signal and measurement of the system’s impedance. In this paper, we overcome this limitation by implementing a measurement strategy consisting of cycles of fast alternating low- and high-voltage signals applied on electrodes covered with mammalian cells. This approach is capable of registering the fast impedance changes during the transient regime corresponding to the cell wounding process. Furthermore, these quasi-simultaneous high- and low-voltage measurements can be compared in order to obtain an empirical correlation between both quantities.
Visualization and Analysis of Geology Word Vectors for Efficient Information Extraction
NASA Astrophysics Data System (ADS)
Floyd, J. S.
2016-12-01
When a scientist begins studying a new geographic region of the Earth, they frequently begin by gathering relevant scientific literature in order to understand what is known, for example, about the region's geologic setting, structure, stratigraphy, and tectonic and environmental history. Experienced scientists typically know what keywords to seek and understand that if a document contains one important keyword, then other words in the document may be important as well. Word relationships in a document give rise to what is known in linguistics as the context-dependent nature of meaning. For example, the meaning of the word `strike' in geology, as in the strike of a fault, is quite different from its popular meaning in baseball. In addition, word order, such as in the phrase `Cretaceous-Tertiary boundary,' often corresponds to the order of sequences in time or space. The context of words and the relevance of words to each other can be derived quantitatively by machine learning vector representations of words. Here we show the results of training a neural network to create word vectors from scientific research papers from selected rift basins and mid-ocean ridges: the Woodlark Basin of Papua New Guinea, the Hess Deep rift, and the Gulf of Mexico basin. The word vectors are statistically defined by surrounding words within a given window, limited by the length of each sentence. The word vectors are analyzed by their cosine distance to related words (e.g., `axial' and `magma'), classified by high dimensional clustering, and visualized by reducing the vector dimensions and plotting the vectors on a two- or three-dimensional graph. Similarity analysis of `Triassic' and `Cretaceous' returns `Jurassic' as the nearest word vector, suggesting that the model is capable of learning the geologic time scale. Similarity analysis of `basalt' and `minerals' automatically returns mineral names such as `chlorite', `plagioclase,' and `olivine.' Word vector analysis and visualization allow one to extract information from hundreds of papers or more and find relationships in less time than it would take to read all of the papers. As machine learning tools become more commonly available, more and more scientists will be able to use and refine these tools for their individual needs.
Higher-order vector beams produced by photonic-crystal lasers.
Iwahashi, Seita; Kurosaka, Yoshitaka; Sakai, Kyosuke; Kitamura, Kyoko; Takayama, Naoki; Noda, Susumu
2011-06-20
We have successfully generated vector beams with higher-order polarization states using photonic-crystal lasers. We have analyzed and designed lattice structures that provide cavity modes with different symmetries. Fabricated devices based on these lattice structures produced doughnut-shaped vector beams, with symmetries corresponding to the cavity modes. Our study enables the systematic analysis of vector beams, which we expect will lead to applications such as high-resolution microscopy, laser processing, and optical trapping.
A simple method of equine limb force vector analysis and its potential applications.
Hobbs, Sarah Jane; Robinson, Mark A; Clayton, Hilary M
2018-01-01
Ground reaction forces (GRF) measured during equine gait analysis are typically evaluated by analyzing discrete values obtained from continuous force-time data for the vertical, longitudinal and transverse GRF components. This paper describes a simple, temporo-spatial method of displaying and analyzing sagittal plane GRF vectors. In addition, the application of statistical parametric mapping (SPM) is introduced to analyse differences between contra-lateral fore and hindlimb force-time curves throughout the stance phase. The overall aim of the study was to demonstrate alternative methods of evaluating functional (a)symmetry within horses. GRF and kinematic data were collected from 10 horses trotting over a series of four force plates (120 Hz). The kinematic data were used to determine clean hoof contacts. The stance phase of each hoof was determined using a 50 N threshold. Vertical and longitudinal GRF for each stance phase were plotted both as force-time curves and as force vector diagrams in which vectors originating at the centre of pressure on the force plate were drawn at intervals of 8.3 ms for the duration of stance. Visual evaluation was facilitated by overlay of the vector diagrams for different limbs. Summary vectors representing the magnitude (VecMag) and direction (VecAng) of the mean force over the entire stance phase were superimposed on the force vector diagram. Typical measurements extracted from the force-time curves (peak forces, impulses) were compared with VecMag and VecAng using partial correlation (controlling for speed). Paired samples t -tests (left v. right diagonal pair comparison and high v. low vertical force diagonal pair comparison) were performed on discrete and vector variables using traditional methods and Hotelling's T 2 tests on normalized stance phase data using SPM. Evidence from traditional statistical tests suggested that VecMag is more influenced by the vertical force and impulse, whereas VecAng is more influenced by the longitudinal force and impulse. When used to evaluate mean data from the group of ten sound horses, SPM did not identify differences between the left and right contralateral limb pairs or between limb pairs classified according to directional asymmetry. When evaluating a single horse, three periods were identified during which differences in the forces between the left and right forelimbs exceeded the critical threshold ( p < .01). Traditional statistical analysis of 2D GRF peak values, summary vector variables and visual evaluation of force vector diagrams gave harmonious results and both methods identified the same inter-limb asymmetries. As alpha was more tightly controlled using SPM, significance was only found in the individual horse although T 2 plots followed the same trends as discrete analysis for the group. The techniques of force vector analysis and SPM hold promise for investigations of sidedness and asymmetry in horses.
NASA Astrophysics Data System (ADS)
Marley, Daniel Edison
A summary of two orthogonal and complementary searches for pair production of heavy vector-like quarks is presented. The first analysis considers final states with 1-lepton and hadronic jets that can be used to reconstruct the vector-like quark system after identifying the boosted decay of W bosons and building the neutrino from the missing transverse momentum. Control and signal regions constrain the uncertainties associated with top quark production that most negatively impact this analysis. The second analysis searches in the fully-hadronic final state where no leptons are considered. An explicit veto on the lepton number ensures orthogonality between the analyses. The analysis uses a deep neural network to reconstruct the decays of heavy objects and a data-driven technique to estimate the dominant multi-jet background. Data were recorded by the ATLAS experiment in sqrt(s)=13 TeV proton-proton collisions delivered by the Large Hadron Collider in 2015 and 2016. No excess above the Standard Model background is observed in either analysis. The results from the 1-lepton analysis are interpreted assuming vector-like quarks decay TT¯ → Wb + X. The 0-lepton analysis assumes both types of pair produced vector-like quarks TT and BB that decay to T → Wb, Ht, Zt and B → Wt, Hb, Zb. The 1-lepton analysis observes a 95% CL lower limit on the T mass of 1090 (810) GeV assuming the scenario BR(T → Wb)=1 (SU(2) singlet). The strongest observed 95% CL lower limits in the 0-lepton analysis are 850 GeV and 903 GeV in the BR(T → Ht) = 1 and BR(B → Hb)=1 decays, respectively.
López-Alvarenga, J C; Sobrino-Cossío, S; Remes-Troche, J M; Chiu-Ugalde, J; Vargas-Romero, J A; Schmulson, M
2013-01-01
Irritable Bowel Syndrome (IBS) is a disorder characterized by abdominal pain or discomfort associated with changes in bowel habit. Currently there are no objective outcome measures for evaluating the effectiveness of treatments for this disorder. To determine the usefulness of a method of analysis that employs polar vectors to evaluate the effectiveness of IBS treatments. Data from a Phase IV clinical study with 1677 active IBS-Rome III patients who received 100mg of pinaverium bromide+300mg of simethicone (PB+S) po bid for a period of four weeks were used for the analysis. Using the Bristol Stool Scale as a reference, the consistency and frequency of each type of bowel movement were recorded weekly in a Bristol Matrix (BM) and the data were expressed as polar vectors. The analysis showed a differential response to the PB+S treatment among the IBS subtypes: in reference to the IBS with constipation subtype, the magnitude of the vector increased from 10.2 to 12.5, reaching maximum improvement at two weeks of treatment (p<0.05, Scheffé). In the IBS with diarrhea and mixed IBS subtypes, the magnitude of the vector decreased from 19 to 14 (p<0.05) and from 16.5 to 13 (p<0.05), respectively, with continuous improvement for a period of four weeks. There was no definable vectorial pattern in the unsubtyped IBS group. Analysis with polar vectors enables treatment response to be measured in different IBS subtypes. All the groups showed improvement with PB+S, but each one had its own characteristic response in relation to vector magnitude and direction. The proposed method can be implemented in clinical studies to evaluate the efficacy of IBS treatments. Copyright © 2012 Asociación Mexicana de Gastroenterología. Published by Masson Doyma México S.A. All rights reserved.
NASA Astrophysics Data System (ADS)
Gang, Zhang; Fansong, Meng; Jianzhong, Wang; Mingtao, Ding
2018-02-01
Determining magnetotelluric impedance precisely and accurately is fundamental to valid inversion and geological interpretation. This study aims to determine the minimum value of signal-to-noise ratio (SNR) which maintains the effectiveness of remote reference technique. Results of standard time series simulation, addition of different Gaussian noises to obtain the different SNR time series, and analysis of the intermediate data, such as polarization direction, correlation coefficient, and impedance tensor, show that when the SNR value is larger than 23.5743, the polarization direction disorder at morphology and a smooth and accurate sounding carve value can be obtained. At this condition, the correlation coefficient value of nearly complete segments between the base and remote station is larger than 0.9, and impedance tensor Zxy presents only one aggregation, which meet the natural magnetotelluric signal characteristic.
Simulated impedance of diffusion in porous media
Cooper, Samuel J.; Bertei, Antonio; Finegan, Donal P.; ...
2017-07-27
This paper describes the use of a frequency domain, finite-difference scheme to simulate the impedance spectra of diffusion in porous microstructures. We investigate both open and closed systems for a range of ideal geometries, as well as some randomly generated synthetic volumes and tomographically derived microstructural data. In many cases, the spectra deviate significantly from the conventional Warburg-type elements typically used to represent diffusion in equivalent circuit analysis. Furthermore, a key finding is that certain microstructures show multiple peaks in the complex plane, which may be misinterpreted as separate electrochemical processes in real impedance data. This is relevant to batterymore » electrode design as the techniques for nano-scale fabrication become more widespread. This simulation tool is provided as an open-source MatLab application and is freely available online as part of the TauFactor platform.« less
NASA Astrophysics Data System (ADS)
Rochmah, D. N.; Syakir, N.; Susilawati, T.; Suryaningsih, S.; Fitrilawati
2017-05-01
The hybrid polymer precursor was synthesized from monomer of 3-(trimethoxysilyl) propyl methacrylate (TMSPMA) using sol-gel method and doped with inhibitor of Cerium Nitrate Hexahydrate with a concentration of 0.2%. The synthesized material was coated on a carbon steel surface by solution casting technique and followed by a photopolymerisation process. Corrosion tests were performed by using Electrochemical Impedance Spectroscopy (EIS) in 3.5% NaCl at the critical temperature of 75°C. Result of EIS data and their fitting analysis using an equivalent circuit model shows that a coating of poly(TMSPMA)-Cerium on the surface of carbon steel form a layer of protection and caused increasing of impedance value significantly. The impedance is higher compared to the carbon steel that coated with poly(TMSPMA) only.
Electrochemical Impedance Sensors for Monitoring Trace Amounts of NO3 in Selected Growing Media.
Ghaffari, Seyed Alireza; Caron, William-O; Loubier, Mathilde; Normandeau, Charles-O; Viens, Jeff; Lamhamedi, Mohammed S; Gosselin, Benoit; Messaddeq, Younes
2015-07-21
With the advent of smart cities and big data, precision agriculture allows the feeding of sensor data into online databases for continuous crop monitoring, production optimization, and data storage. This paper describes a low-cost, compact, and scalable nitrate sensor based on electrochemical impedance spectroscopy for monitoring trace amounts of NO3- in selected growing media. The nitrate sensor can be integrated to conventional microelectronics to perform online nitrate sensing continuously over a wide concentration range from 0.1 ppm to 100 ppm, with a response time of about 1 min, and feed data into a database for storage and analysis. The paper describes the structural design, the Nyquist impedance response, the measurement sensitivity and accuracy, and the field testing of the nitrate sensor performed within tree nursery settings under ISO/IEC 17025 certifications.
Electrochemical Impedance Sensors for Monitoring Trace Amounts of NO3 in Selected Growing Media
Ghaffari, Seyed Alireza; Caron, William-O.; Loubier, Mathilde; Normandeau, Charles-O.; Viens, Jeff; Lamhamedi, Mohammed S.; Gosselin, Benoit; Messaddeq, Younes
2015-01-01
With the advent of smart cities and big data, precision agriculture allows the feeding of sensor data into online databases for continuous crop monitoring, production optimization, and data storage. This paper describes a low-cost, compact, and scalable nitrate sensor based on electrochemical impedance spectroscopy for monitoring trace amounts of NO3− in selected growing media. The nitrate sensor can be integrated to conventional microelectronics to perform online nitrate sensing continuously over a wide concentration range from 0.1 ppm to 100 ppm, with a response time of about 1 min, and feed data into a database for storage and analysis. The paper describes the structural design, the Nyquist impedance response, the measurement sensitivity and accuracy, and the field testing of the nitrate sensor performed within tree nursery settings under ISO/IEC 17025 certifications. PMID:26197322
Impedance matching wireless power transmission system for biomedical devices.
Lum, Kin Yun; Lindén, Maria; Tan, Tian Swee
2015-01-01
For medical application, the efficiency and transmission distance of the wireless power transfer (WPT) are always the main concern. Research has been showing that the impedance matching is one of the critical factors for dealing with the problem. However, there is not much work performed taking both the source and load sides into consideration. Both sides matching is crucial in achieving an optimum overall performance, and the present work proposes a circuit model analysis for design and implementation. The proposed technique was validated against experiment and software simulation. Result was showing an improvement in transmission distance up to 6 times, and efficiency at this transmission distance had been improved up to 7 times as compared to the impedance mismatch system. The system had demonstrated a near-constant transfer efficiency for an operating range of 2cm-12cm.
Changes in impedance of Ni/Cd cells with voltage and cycle life
NASA Technical Reports Server (NTRS)
Reid, Margaret A.
1992-01-01
Impedances of aerospace design Super Ni/Cd cells are being measured as functions of voltage and number of cycles. The cells have been cycled over 4400 cycles to date. Analysis of the impedance data has been made using a number of equivalent circuits. The model giving the best fit over the whole range of voltage has a parallel circuit of a kinetic resistance and a constant phase element in series with the ohmic resistance. The values for the circuit elements have been treated as empirical parameters, and no attempt has been made as yet to correlate them with physical and chemical changes in the electrode. No significant changes have been seen as yet with the exception of a decrease in kinetic resistance at low states of charge in the first 500 cycles.
Zhang, Wenli; Muck-Hausl, Martin; Wang, Jichang; Sun, Chuanbo; Gebbing, Maren; Miskey, Csaba; Ivics, Zoltan; Izsvak, Zsuzsanna; Ehrhardt, Anja
2013-01-01
We recently developed adenovirus/transposase hybrid-vectors utilizing the previously described hyperactive Sleeping Beauty (SB) transposase HSB5 for somatic integration and we could show stabilized transgene expression in mice and a canine model for hemophilia B. However, the safety profile of these hybrid-vectors with respect to vector dose and genotoxicity remains to be investigated. Herein, we evaluated this hybrid-vector system in C57Bl/6 mice with escalating vector dose settings. We found that in all mice which received the hyperactive SB transposase, transgene expression levels were stabilized in a dose-dependent manner and that the highest vector dose was accompanied by fatalities in mice. To analyze potential genotoxic side-effects due to somatic integration into host chromosomes, we performed a genome-wide integration site analysis using linker-mediated PCR (LM-PCR) and linear amplification-mediated PCR (LAM-PCR). Analysis of genomic DNA samples obtained from HSB5 treated female and male mice revealed a total of 1327 unique transposition events. Overall the chromosomal distribution pattern was close-to-random and we observed a random integration profile with respect to integration into gene and non-gene areas. Notably, when using the LM-PCR protocol, 27 extra-chromosomal integration events were identified, most likely caused by transposon excision and subsequent transposition into the delivered adenoviral vector genome. In total, this study provides a careful evaluation of the safety profile of adenovirus/Sleeping Beauty transposase hybrid-vectors. The obtained information will be useful when designing future preclinical studies utilizing hybrid-vectors in small and large animal models. PMID:24124483
Cho, Youngho; Hur, Kyeon; Kang, Yong; ...
2017-09-08
This study investigates the emerging harmonic stability concerns to be addressed by grid planners in generation interconnection studies, owing to the increased adoption of renewable energy resources connected to the grid via power electronic converters. The wideband and high-frequency electromagnetic transient (EMT) characteristics of these converter-interfaced generators (CIGs) and their interaction with the grid impedance are not accurately captured in the typical dynamic studies conducted by grid planners. This paper thus identifies the desired components to be studied and subsequently develops a practical process for integrating a new CIG into a grid with the existing CIGs. The steps of thismore » process are as follows: the impedance equation of a CIG using its control dynamics and an interface filter to the grid, for example, an LCL filter (inductor-capacitor-inductor type), is developed; an equivalent impedance model including the existing CIGs nearby and the grid observed from the point of common coupling are derived; the system stability for credible operating scenarios is assessed. Detailed EMT simulations validate the accuracy of the impedance models and stability assessment for various connection scenarios. Here, by complementing the conventional EMT simulation studies, the proposed analytical approach enables grid planners to identify critical design parameters for seamlessly integrating a new CIG and ensuring the reliability of the grid.« less
Zhao, Lingxi; Zhou, Yu; Song, Chengli; Wang, Zhigang; Cuschieri, Alfred
2017-03-01
The present study investigates the relationship between bio-impedance and burst pressure of colorectal anastomosis created by radiofrequency (RF)-induced tissue fusion. Colorectal anastomosis were created with ex vivo porcine colorectal segments, during which 5 levels of compression pressure were applied by a custom-made bipolar prototype, with 5 replicate experiments at each compression pressure. Instant anastomotic tensile strength was assessed by burst pressure. Bio-impedance of fused tissue was measured by Impedance Analyzer across frequency that 100 Hz to 3 MHz. Statistical analysis shows only a weak correlation between bio-impedance modulus and burst pressures at frequency of 445 kHz ([Formula: see text] = -0.426, P = 0.099 > 0.05). In contrast, results demonstrated a highly significant negative correlation between reactance modulus and burst pressures ([Formula: see text] = -0.812, P = 0.000 < 0.05). The decrease in mean reactance modulus with increasing burst pressures was highly significant (P = 0.019 < 0.05). The observed strong negative correlation between reactance modulus and burst pressures at frequency of 445 kHz indicates that reactance is likely to be a good index for tensile strength of RF-induced colorectal anastomosis, and should be considered for inclusion in a feedback loops in devices design.
NASA Astrophysics Data System (ADS)
Mahajan, Sandeep; Thakur, O P; Bhattacharya, D K; Sreenivas, K
2009-03-01
Bi2O3-doped barium zirconate titanate ceramics, Ba1-xBix(Zr0.05Ti0.95)O3, have been prepared by the conventional solid-state reaction method. The ferroelectric relaxor behaviour and dielectric properties have been investigated in detail. By XRD analysis, it is suggested that up to x = 0.04, Bi3+ substitutes A-site ion, and thereafter with higher Bi3+ content, it enters the B-site sub lattice. Substitution of Bi3+ ions induces ferroelectric relaxor behaviour and the degree of relaxation behaviour increases with bismuth concentration. The remanent polarization and strain behaviour show a slight increase with the substitution level. The degree of hysteresis (strain versus electric field) also reduces from 21.4% to 4.6% with bismuth substitution. Impedance measurements were made on the prepared sample over a wide range of temperatures (300-723 K) and frequencies (40 Hz-1 MHz), which show the presence of both bulk and grain boundary effects in the material. The bulk and grain boundary conductivities determined from impedance study indicate the Arrhenius-type thermally activated process. Impedance spectroscopy is shown to be an efficient method capable of detecting the contributions of the resistances of grains and grain boundaries to the complex impedance of a ceramic system, accurately estimating its electrical conductivity as well as its corresponding activation energies and drawing conclusions on its structural properties.
Wave impedance selection for passivity-based bilateral teleoperation
NASA Astrophysics Data System (ADS)
D'Amore, Nicholas John
When a task must be executed in a remote or dangerous environment, teleoperation systems may be employed to extend the influence of the human operator. In the case of manipulation tasks, haptic feedback of the forces experienced by the remote (slave) system is often highly useful in improving an operator's ability to perform effectively. In many of these cases (especially teleoperation over the internet and ground-to-space teleoperation), substantial communication latency exists in the control loop and has the strong tendency to cause instability of the system. The first viable solution to this problem in the literature was based on a scattering/wave transformation from transmission line theory. This wave transformation requires the designer to select a wave impedance parameter appropriate to the teleoperation system. It is widely recognized that a small value of wave impedance is well suited to free motion and a large value is preferable for contact tasks. Beyond this basic observation, however, very little guidance exists in the literature regarding the selection of an appropriate value. Moreover, prior research on impedance selection generally fails to account for the fact that in any realistic contact task there will simultaneously exist contact considerations (perpendicular to the surface of contact) and quasi-free-motion considerations (parallel to the surface of contact). The primary contribution of the present work is to introduce an approximate linearized optimum for the choice of wave impedance and to apply this quasi-optimal choice to the Cartesian reality of such a contact task, in which it cannot be expected that a given joint will be either perfectly normal to or perfectly parallel to the motion constraint. The proposed scheme selects a wave impedance matrix that is appropriate to the conditions encountered by the manipulator. This choice may be implemented as a static wave impedance value or as a time-varying choice updated according to the instantaneous conditions encountered. A Lyapunov-like analysis is presented demonstrating that time variation in wave impedance will not violate the passivity of the system. Experimental trials, both in simulation and on a haptic feedback device, are presented validating the technique. Consideration is also given to the case of an uncertain environment, in which an a priori impedance choice may not be possible.
Foliar nutrient analysis of sugar maple decline: retrospective vector diagnosis
Victor R. Timmer; Yuanxin Teng
1999-01-01
Accuracy of traditional foiiar analysis of nutrient disorders in sugar maple (Acer saccharum Marsh) is limited by lack of validation and confounding by nutrient interactions. Vector nutrient diagnosis is relatively free of these problems. The technique is demonstrated retrospectively on four case studies. Diagnostic interpretations consistently...
Analysis of Asymmetry by a Slide-Vector.
ERIC Educational Resources Information Center
Zielman, Berrie; Heiser, Willem J.
1993-01-01
An algorithm based on the majorization theory of J. de Leeuw and W. J. Heiser is presented for fitting the slide-vector model. It views the model as a constrained version of the unfolding model. A three-way variant is proposed, and two examples from market structure analysis are presented. (SLD)
Analysis of vector wind change with respect to time for Vandenberg Air Force Base, California
NASA Technical Reports Server (NTRS)
Adelfang, S. I.
1978-01-01
A statistical analysis of the temporal variability of wind vectors at 1 km altitude intervals from 0 to 27 km altitude taken from a 10-year data sample of twice-daily rawinsode wind measurements over Vandenberg Air Force Base, California is presented.
Thrust vectoring for lateral-directional stability
NASA Technical Reports Server (NTRS)
Peron, Lee R.; Carpenter, Thomas
1992-01-01
The advantages and disadvantages of using thrust vectoring for lateral-directional control and the effects of reducing the tail size of a single-engine aircraft were investigated. The aerodynamic characteristics of the F-16 aircraft were generated by using the Aerodynamic Preliminary Analysis System II panel code. The resulting lateral-directional linear perturbation analysis of a modified F-16 aircraft with various tail sizes and yaw vectoring was performed at several speeds and altitudes to determine the stability and control trends for the aircraft compared to these trends for a baseline aircraft. A study of the paddle-type turning vane thrust vectoring control system as used on the National Aeronautics and Space Administration F/A-18 High Alpha Research Vehicle is also presented.
Superconducting fault current-limiter with variable shunt impedance
Llambes, Juan Carlos H; Xiong, Xuming
2013-11-19
A superconducting fault current-limiter is provided, including a superconducting element configured to resistively or inductively limit a fault current, and one or more variable-impedance shunts electrically coupled in parallel with the superconducting element. The variable-impedance shunt(s) is configured to present a first impedance during a superconducting state of the superconducting element and a second impedance during a normal resistive state of the superconducting element. The superconducting element transitions from the superconducting state to the normal resistive state responsive to the fault current, and responsive thereto, the variable-impedance shunt(s) transitions from the first to the second impedance. The second impedance of the variable-impedance shunt(s) is a lower impedance than the first impedance, which facilitates current flow through the variable-impedance shunt(s) during a recovery transition of the superconducting element from the normal resistive state to the superconducting state, and thus, facilitates recovery of the superconducting element under load.
Mackey, Allison R; Hodgetts, William E; Scott, Dylan; Small, Susan A
2016-01-01
Little is known about the maturational changes in the mechanical properties of the skull and how they might contribute to infant-adult differences in bone conduction hearing sensitivity. The objective of this study was to investigate the mechanical impedance of the skin-covered skull for different skull positions and contact forces for groups of infants, young children, and adults. These findings provide a better understanding of how changes in mechanical impedance might contribute to developmental changes in bone conduction hearing, and might provide insight into how fitting and output verification protocols for bone-anchored hearing systems (BAHS) could be adapted for infants and young children. Seventy-seven individuals participated in the study, including 63 infants and children (ages 1 month to 7 years) and 11 adults. Mechanical impedance magnitude for the forehead and temporal bone was collected for contact forces of 2, 4, and 5.4 N using an impedance head, a BAHS transducer, and a specially designed holding device. Mechanical impedance magnitude was determined across frequency using a stepped sine sweep from 100 to 10,000 Hz, and divided into low- and high-frequency sets for analysis. Mechanical impedance magnitude was lowest for the youngest infants and increased throughout maturation in the low frequencies. For high frequencies, the youngest infants had the highest impedance, but only for a temporal bone placement. Impedance increased with increasing contact force for low frequencies for each age group and for both skull positions. The effect of placement was significant for high frequencies for each contact force and for each age group, except for the youngest infants. Our findings show that mechanical impedance properties change systematically up to 7 years old. The significant age-related differences in mechanical impedance suggest that infant-adult differences in bone conduction thresholds may be related, at least in part, to properties of the immature skull and overlying skin and tissues. These results have important implications for fitting the soft band BAHS on infants and young children. For example, verification of output force form a BAHS on a coupler designed with adult values may not be appropriate for infants. This may also hold true for transducer calibration when assessing bone conduction hearing thresholds in infants for different skull locations. The results have two additional clinical implications for fitting soft band BAHSs. First, parents should be counseled to maintain sufficient and consistent tightness so that the output from the BAHS does not change as the child moves around during everyday activities. Second, placement of a BAHS on the forehead versus the temporal bone results in changes in mechanical impedance which may contribute to a decrease in signal level at the cochlea as it has been previously demonstrated that bone conduction thresholds are poorer at the forehead compared with a temporal placement.
NASA Technical Reports Server (NTRS)
Kory, Carol L.
1999-01-01
The phenomenal growth of commercial communications has created a great demand for traveling-wave tube (TWT) amplifiers. Although the helix slow-wave circuit remains the mainstay of the TWT industry because of its exceptionally wide bandwidth, until recently it has been impossible to accurately analyze a helical TWT using its exact dimensions because of the complexity of its geometrical structure. For the first time, an accurate three-dimensional helical model was developed that allows accurate prediction of TWT cold-test characteristics including operating frequency, interaction impedance, and attenuation. This computational model, which was developed at the NASA Lewis Research Center, allows TWT designers to obtain a more accurate value of interaction impedance than is possible using experimental methods. Obtaining helical slow-wave circuit interaction impedance is an important part of the design process for a TWT because it is related to the gain and efficiency of the tube. This impedance cannot be measured directly; thus, conventional methods involve perturbing a helical circuit with a cylindrical dielectric rod placed on the central axis of the circuit and obtaining the difference in resonant frequency between the perturbed and unperturbed circuits. A mathematical relationship has been derived between this frequency difference and the interaction impedance (ref. 1). However, because of the complex configuration of the helical circuit, deriving this relationship involves several approximations. In addition, this experimental procedure is time-consuming and expensive, but until recently it was widely accepted as the most accurate means of determining interaction impedance. The advent of an accurate three-dimensional helical circuit model (ref. 2) made it possible for Lewis researchers to fully investigate standard approximations made in deriving the relationship between measured perturbation data and interaction impedance. The most prominent approximations made in the analysis were addressed and fully investigated for their accuracy by using the three-dimensional electromagnetic simulation code MAFIA (Solution of Maxwell's Equations by the Finite Integration Algorithm) (refs. 3 and 4). We found that several approximations introduced significant error (ref. 5).
Liang, Zhen; Li, Bin; Huang, Mo; Zheng, Yanqi; Ye, Hui; Xu, Ken; Deng, Fangming
2017-04-19
In this work, a low cost Bluetooth Low Energy (BLE) transceiver for wireless sensor network (WSN) applications, with a receiver (RX)-matching network-reusing power amplifier (PA) load inductor, is presented. In order to decrease the die area, only two inductors were used in this work. Besides the one used in the voltage control oscillator (VCO), the PA load inductor was reused as the RX impedance matching component in the front-end. Proper controls have been applied to achieve high transmitter (TX) input impedance when the transceiver is in the receiving mode, and vice versa. This allows the TRX-switch/matching network integration without significant performance degradation. The RX adopted a low-IF structure and integrated a single-ended low noise amplifier (LNA), a current bleeding mixer, a 4th complex filter and a delta-sigma continuous time (CT) analog-to-digital converter (ADC). The TX employed a two-point PLL-based architecture with a non-linear PA. The RX achieved a sensitivity of -93 dBm and consumes 9.7 mW, while the TX achieved a 2.97% error vector magnitude (EVM) with 9.4 mW at 0 dBm output power. This design was fabricated in a 0.11 μm complementary metal oxide semiconductor (CMOS) technology and the front-end circuit only occupies 0.24 mm². The measurement results verify the effectiveness and applicability of the proposed BLE transceiver for WSN applications.
SSM/I and ECMWF Wind Vector Comparison
NASA Technical Reports Server (NTRS)
Wentz, Frank J.; Ashcroft, Peter D.
1996-01-01
Wentz was the first to convincingly show that satellite microwave radiometers have the potential to measure the oceanic wind vector. The most compelling evidence for this conclusion was the monthly wind vector maps derived solely from a statistical analysis of Special Sensor Microwave Imager (SSM/I) observations. In a qualitative sense, these maps clearly showed the general circulation over the world's oceans. In this report we take a closer look at the SSM/I monthly wind vector maps and compare them to European Center for Medium-Range Weather Forecasts (ECMWF) wind fields. This investigation leads both to an empirical comparison of SSM/I calculated wind vectors with ECMWF wind vectors, and to an examination of possible reasons that the SSM/I calculated wind vector direction would be inherently more reliable at some locations than others.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Xiaoyu; Hao, Zhenqi; Wu, Di
Here, we report quantitative measurements of nanoscale permittivity and conductivity using tuning-fork (TF) based microwave impedance microscopy (MIM). The system is operated under the driving amplitude modulation mode, which ensures satisfactory feedback stability on samples with rough surfaces. The demodulated MIM signals on a series of bulk dielectrics are in good agreement with results simulated by finite-element analysis. Using the TF-MIM, we have visualized the evolution of nanoscale conductance on back-gated MoS 2 field effect transistors, and the results are consistent with the transport data. Our work suggests that quantitative analysis of mesoscopic electrical properties can be achieved by near-fieldmore » microwave imaging with small distance modulation.« less
Wu, Xiaoyu; Hao, Zhenqi; Wu, Di; ...
2018-04-01
Here, we report quantitative measurements of nanoscale permittivity and conductivity using tuning-fork (TF) based microwave impedance microscopy (MIM). The system is operated under the driving amplitude modulation mode, which ensures satisfactory feedback stability on samples with rough surfaces. The demodulated MIM signals on a series of bulk dielectrics are in good agreement with results simulated by finite-element analysis. Using the TF-MIM, we have visualized the evolution of nanoscale conductance on back-gated MoS 2 field effect transistors, and the results are consistent with the transport data. Our work suggests that quantitative analysis of mesoscopic electrical properties can be achieved by near-fieldmore » microwave imaging with small distance modulation.« less
A FEM-based method to determine the complex material properties of piezoelectric disks.
Pérez, N; Carbonari, R C; Andrade, M A B; Buiochi, F; Adamowski, J C
2014-08-01
Numerical simulations allow modeling piezoelectric devices and ultrasonic transducers. However, the accuracy in the results is limited by the precise knowledge of the elastic, dielectric and piezoelectric properties of the piezoelectric material. To introduce the energy losses, these properties can be represented by complex numbers, where the real part of the model essentially determines the resonance frequencies and the imaginary part determines the amplitude of each resonant mode. In this work, a method based on the Finite Element Method (FEM) is modified to obtain the imaginary material properties of piezoelectric disks. The material properties are determined from the electrical impedance curve of the disk, which is measured by an impedance analyzer. The method consists in obtaining the material properties that minimize the error between experimental and numerical impedance curves over a wide range of frequencies. The proposed methodology starts with a sensitivity analysis of each parameter, determining the influence of each parameter over a set of resonant modes. Sensitivity results are used to implement a preliminary algorithm approaching the solution in order to avoid the search to be trapped into a local minimum. The method is applied to determine the material properties of a Pz27 disk sample from Ferroperm. The obtained properties are used to calculate the electrical impedance curve of the disk with a Finite Element algorithm, which is compared with the experimental electrical impedance curve. Additionally, the results were validated by comparing the numerical displacement profile with the displacements measured by a laser Doppler vibrometer. The comparison between the numerical and experimental results shows excellent agreement for both electrical impedance curve and for the displacement profile over the disk surface. The agreement between numerical and experimental displacement profiles shows that, although only the electrical impedance curve is considered in the adjustment procedure, the obtained material properties allow simulating the displacement amplitude accurately. Copyright © 2014 Elsevier B.V. All rights reserved.
Computational mechanics analysis tools for parallel-vector supercomputers
NASA Technical Reports Server (NTRS)
Storaasli, O. O.; Nguyen, D. T.; Baddourah, M. A.; Qin, J.
1993-01-01
Computational algorithms for structural analysis on parallel-vector supercomputers are reviewed. These parallel algorithms, developed by the authors, are for the assembly of structural equations, 'out-of-core' strategies for linear equation solution, massively distributed-memory equation solution, unsymmetric equation solution, general eigen-solution, geometrically nonlinear finite element analysis, design sensitivity analysis for structural dynamics, optimization algorithm and domain decomposition. The source code for many of these algorithms is available from NASA Langley.
NASA Technical Reports Server (NTRS)
Nguyen, Duc T.; Storaasli, Olaf O.; Qin, Jiangning; Qamar, Ramzi
1994-01-01
An automatic differentiation tool (ADIFOR) is incorporated into a finite element based structural analysis program for shape and non-shape design sensitivity analysis of structural systems. The entire analysis and sensitivity procedures are parallelized and vectorized for high performance computation. Small scale examples to verify the accuracy of the proposed program and a medium scale example to demonstrate the parallel vector performance on multiple CRAY C90 processors are included.
Observation of Polarization-Locked Vector Solitons in an Optical Fiber
NASA Astrophysics Data System (ADS)
Cundiff, S. T.; Collings, B. C.; Akhmediev, N. N.; Soto-Crespo, J. M.; Bergman, K.; Knox, W. H.
1999-05-01
We observe polarization-locked vector solitons in a mode-locked fiber laser. Temporal vector solitons have components along both birefringent axes. Despite different phase velocities due to linear birefringence, the relative phase of the components is locked at +/-π/2. The value of +/-π/2 and component magnitudes agree with a simple analysis of the Kerr nonlinearity. These fragile phase-locked vector solitons have been the subject of much theoretical conjecture, but have previously eluded experimental observation.
NASA Astrophysics Data System (ADS)
Ferhat, Ipar
With increasing advancement in material science and computational power of current computers that allows us to analyze high dimensional systems, very light and large structures are being designed and built for aerospace applications. One example is a reflector of a space telescope that is made of membrane structures. These reflectors are light and foldable which makes the shipment easy and cheaper unlike traditional reflectors made of glass or other heavy materials. However, one of the disadvantages of membranes is that they are very sensitive to external changes, such as thermal load or maneuvering of the space telescope. These effects create vibrations that dramatically affect the performance of the reflector. To overcome vibrations in membranes, in this work, piezoelectric actuators are used to develop distributed controllers for membranes. These actuators generate bending effects to suppress the vibration. The actuators attached to a membrane are relatively thick which makes the system heterogeneous; thus, an analytical solution cannot be obtained to solve the partial differential equation of the system. Therefore, the Finite Element Model is applied to obtain an approximate solution for the membrane actuator system. Another difficulty that arises with very flexible large structures is the dimension of the discretized system. To obtain an accurate result, the system needs to be discretized using smaller segments which makes the dimension of the system very high. This issue will persist as long as the improving technology will allow increasingly complex and large systems to be designed and built. To deal with this difficulty, the analysis of the system and controller development to suppress the vibration are carried out using vector second order form as an alternative to vector first order form. In vector second order form, the number of equations that need to be solved are half of the number equations in vector first order form. Analyzing the system for control characteristics such as stability, controllability and observability is a key step that needs to be carried out before developing a controller. This analysis determines what kind of system is being modeled and the appropriate approach for controller development. Therefore, accuracy of the system analysis is very crucial. The results of the system analysis using vector second order form and vector first order form show the computational advantages of using vector second order form. Using similar concepts, LQR and LQG controllers, that are developed to suppress the vibration, are derived using vector second order form. To develop a controller using vector second order form, two different approaches are used. One is reducing the size of the Algebraic Riccati Equation to half by partitioning the solution matrix. The other approach is using the Hamiltonian method directly in vector second order form. Controllers are developed using both approaches and compared to each other. Some simple solutions for special cases are derived for vector second order form using the reduced Algebraic Riccati Equation. The advantages and drawbacks of both approaches are explained through examples. System analysis and controller applications are carried out for a square membrane system with four actuators. Two different systems with different actuator locations are analyzed. One system has the actuators at the corners of the membrane, the other has the actuators away from the corners. The structural and control effect of actuator locations are demonstrated with mode shapes and simulations. The results of the controller applications and the comparison of the vector first order form with the vector second order form demonstrate the efficacy of the controllers.
Symbolic computer vector analysis
NASA Technical Reports Server (NTRS)
Stoutemyer, D. R.
1977-01-01
A MACSYMA program is described which performs symbolic vector algebra and vector calculus. The program can combine and simplify symbolic expressions including dot products and cross products, together with the gradient, divergence, curl, and Laplacian operators. The distribution of these operators over sums or products is under user control, as are various other expansions, including expansion into components in any specific orthogonal coordinate system. There is also a capability for deriving the scalar or vector potential of a vector field. Examples include derivation of the partial differential equations describing fluid flow and magnetohydrodynamics, for 12 different classic orthogonal curvilinear coordinate systems.
Ma, Ning-Qiang; Liu, Li-Li; Min, Jie; Wang, Jun-Wei; Jiang, Wei-Feng; Liu, Yan; Feng, Yan-Guo; Su, Hai-Chuan; Feng, Ying-Ming; Zhang, He-Long
2011-12-01
Bone is the third most common site of cancer metastasis. Over 30 to 40% of lung cancers can develop skeletal metastasis and no effective curative therapy exists in clinic cases. Previously we screened the different expression of proteins between SBC-5 cells and SBC-3 cells by proteomic study methods (MALDI-TOF/TOF-MS) and found that calcineurin (hereafter referred as Cn) overexpresses in SBC-5 which has special priority in metastasis to bone in a multiple-organ metastasis mice model. However the roles of Cn in osteotropism of SCLC remain to be elucidated. At present study, we decrease CnAα expression in SBC-5 by lentiviral vector-mediated RNAi and found that down regulation of CnAα gene expression can decrease the proliferation and colony formation rate, impede the cell cycle progression, reduce the cell migration and invasion, and inhibit cells adhering to bone matrix, but not change the apoptosis rate of SBC-5 in vitro. In vivo down or up regulation of CnAα gene expression can only decrease or increase the bone metastasis rate, but not affect the metastasis rate to the visceral organs. Our research reveals that CnAα is closely related to the osteotropism metastasis of SCLC and a candidate tumor promotor gene for developing bone metastases.
Kagale, Sateesh; Uzuhashi, Shihomi; Wigness, Merek; Bender, Tricia; Yang, Wen; Borhan, M. Hossein; Rozwadowski, Kevin
2012-01-01
Plant viral expression vectors are advantageous for high-throughput functional characterization studies of genes due to their capability for rapid, high-level transient expression of proteins. We have constructed a series of tobacco mosaic virus (TMV) based vectors that are compatible with Gateway technology to enable rapid assembly of expression constructs and exploitation of ORFeome collections. In addition to the potential of producing recombinant protein at grams per kilogram FW of leaf tissue, these vectors facilitate either N- or C-terminal fusions to a broad series of epitope tag(s) and fluorescent proteins. We demonstrate the utility of these vectors in affinity purification, immunodetection and subcellular localisation studies. We also apply the vectors to characterize protein-protein interactions and demonstrate their utility in screening plant pathogen effectors. Given its broad utility in defining protein properties, this vector series will serve as a useful resource to expedite gene characterization efforts. PMID:23166857
Dropulic, Boro
2005-07-01
The recent development of leukemia in three patients following retroviral vector gene transfer in hematopoietic stem cells, resulting in the death of one patient, has raised safety concerns for the use of integrating gene transfer vectors for human gene therapy. This review discusses these serious adverse events from the perspective of whether restrictions on vector design and vector-modified target cells are warranted at this time. A case is made against presently establishing specific restrictions for vector design and transduced cells; rather, their safety should be ascertained by empiric evaluation in appropriate preclinical models on a case-by-case basis. Such preclinical data, coupled with proper informed patient consent and a risk-benefit ratio analysis, provide the best available prospective evaluation of gene transfer vectors prior to their translation into the clinic.
Perturbation-iteration theory for analyzing microwave striplines
NASA Technical Reports Server (NTRS)
Kretch, B. E.
1985-01-01
A perturbation-iteration technique is presented for determining the propagation constant and characteristic impedance of an unshielded microstrip transmission line. The method converges to the correct solution with a few iterations at each frequency and is equivalent to a full wave analysis. The perturbation-iteration method gives a direct solution for the propagation constant without having to find the roots of a transcendental dispersion equation. The theory is presented in detail along with numerical results for the effective dielectric constant and characteristic impedance for a wide range of substrate dielectric constants, stripline dimensions, and frequencies.
Dispersion relation of a surface wave at a rough metal-air interface
Kotelnikov, Igor; Stupakov, Gennady
2016-11-28
Here, we derived a dispersion relation of a surface wave at a rough metal-air interface. In contrast to previous publications, we assumed that an intrinsic surface impedance due to a finite electric conductivity of the metal can be of the same order as the roughness-induced impedance. We then applied our results to the analysis of a long-standing problem of the discrepancy between the experimental data on the propagation of surface waves in the terahertz range of frequencies and the classical Drude theory.
Annual Gaseous Electronics Conference (41st) Held in Minneapolis, Minnesota on 18-21 October 1988
1989-09-01
IMPEDANCE J. W. Butterbaugh, L. D. Baston and H. H. Sawin E-34. TEMPORAL AND SPATIAL PLASMA POTENTIAL MEASUREMENT IN PARALLEL PLATE RF GLOW DISCHARGE C...DISCHARGES P. J. Hargis, Jr. and K. E. Grecr.’ 10:51 - 11:04 LA-4. CHARACTERIZATION OF CF4 PLASMA KINETICS BY MODULATED POWER RELAXATION L. D. Baston and H. H...No. ECS-8704529 5n, E-33 Measurement and Analysis of RF Glow Discharge Electrical Impedance, J.W. BUTTERBAUGH, L.D. BASTON , and H.H. SAWIN