Sample records for implants technical description

  1. Experience in cochlear reimplantation. Descriptive study of a 20-year period.

    PubMed

    Gutiérrez-Salazar, Andrés; Cop, Constanze; Osorio-Acosta, Ángel; Borkoski-Barreiro, Silvia; Falcón-González, Juan C; Ramos-Macías, Ángel

    2015-01-01

    The cochlear implant is a surgical procedure that has increased substantially, because the paediatric population is diagnosed and implanted early and because there are increased potential indications. This device has the inherent risk of failure in performance, as dies any active medical device, which is the most common cause of implant removal. Our goal was to understand what the causes that produced removal in our series were, and confirm if these conformed to reality as reviewed in the literature. This was a retrospective, descriptive, observational study of 859 cochlear implant surgeries carried out between October 1991 and May 2011. The causes of implant removal were classified according to the European Consensus Statement on Cochlear Implant Failures and Explantations. The reimplantation rate was 6.16% (n=51). The most common reason for removal was technical device failure (45.5%), followed by infection/rejection (23.6%) and upgrade (12.7%). Less common causes: there were 3 cases (5.6%) of electrode misplacement, 2 cases (3.6%) of labyrinthine ossification, 2 (3.6%) as a result of head trauma, 2 (3.6%) from need for nuclear magnetic resonance imaging and 1 case (1.8%) from psychiatric illness. Cochlear reimplantation is a safe procedure, with a low complication rate. In our centre, it reaches an overall rate of 6.16%. Technical device failure remains the most common cause of this procedure, although there is a significant percentage of reimplantation for device update. Copyright © 2014 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.

  2. Computer-assisted surgery and intraoral welding technique for immediate implant-supported rehabilitation of the edentulous maxilla: case report and technical description.

    PubMed

    Albiero, Alberto Maria; Benato, Renato

    2016-09-01

    Complications are frequently reported when combining computer assisted flapless surgery with an immediate loaded prefabricated prosthesis. The authors have combined computer-assisted surgery with the intraoral welding technique to obtain a precise passive fit of the immediate loading prosthesis. An edentulous maxilla was rehabilitated with four computer assisted implants welded together intraorally and immediately loaded with a provisional restoration. A perfect passive fit of the metal framework was obtained that enabled proper osseointegration of implants. Computer assisted preoperative planning has been shown to be effective in reducing the intraoperative time of the intraoral welding technique. No complications were observed at 1 year follow-up. This guided-welded approach is useful to achieve a passive fit of the provisional prosthesis on the inserted implants the same day as the surgery, reducing intraoperative time with respect to the traditional intraoral welding technique. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  3. Clinical success of implant-supported and tooth-implant-supported double crown-retained dentures.

    PubMed

    Bernhart, Gunda; Koob, Andreas; Schmitter, Marc; Gabbert, Olaf; Stober, Thomas; Rammelsberg, Peter

    2012-08-01

    The objective of this retrospective study was to compare biological and technical complications of implant-supported and tooth-implant-supported double crown-retained dentures (DCRDs) with those of tooth-supported DCRDs. Sixty-three DCRDs were monitored. One study group included 16 prostheses with a combination of implants and natural teeth as double crowns (ti group), whereas in the second study group, 19 dentures were retained exclusively on implants (ii group); a third study group with 28 exclusively tooth-supported dentures served as controls (tt group). Tooth loss, implant failure, and technical complications (loss of retention of primary crown, abutment screw loosening, loss of facing, fracture of resin denture teeth and fracture of saddle resin) were analysed. During the observation period of 24 months, no implants or teeth were lost in the ti group and three technical complications were recorded. In the ii group, two implants were lost, two cases of peri-implantitis occurred and four technical complications were observed. In the tt group, two cases of tooth loss and seven technical complications were observed. At the time of the last examination, all prostheses of the ti group and the ii group were functional. Patients of these two study groups reported high satisfaction with both function and aesthetics with no significant difference between the two groups. Treatment with DCRDs showed comparable results in the three study groups. The 2-year results indicate that double crowns can be recommended for implant and combined tooth-implant-retained dentures.

  4. Misfit of implant prostheses and its impact on clinical outcomes. Definition, assessment and a systematic review of the literature.

    PubMed

    Katsoulis, Joannis; Takeichi, Takuro; Sol Gaviria, Ana; Peter, Lukas; Katsoulis, Konstantinos

    Compromised fit between the contact surfaces of screw-retained implant-supported fixed dentures (IFDs) is thought to create uncontrolled strains in the prosthetic components and peri-implant tissues, thus evoking biological and technical complications such as bone loss, screw loosening, component fractures and, at worst, loss of implants or prostheses. The aim of this systematic review was to evaluate the impact of marginal misfit on the clinical outcomes of IFDs, and to elucidate definition and assessment methods for passive fit. A systematic review of the literature was conducted with a PICO question: "For partially or complete edentulous subjects with screw-retained IFDs, does the marginal misfit at the implant-prosthesis interfaces have an impact on the clinical outcomes?". A literature search was performed electronically in PubMed (MEDLINE) with the help of Boolean operators to combine key words, and by hand search in relevant journals. English written in vivo studies published before August 31, 2016 that reported on both clinical outcome and related implant prosthesis misfit (gap, strains, torque) were selected using predetermined inclusion criteria. The initial search yielded 2626 records. After screening and a subsequent filtering process, five human and five animal studies were included in the descriptive analysis. The selected studies used different methods to assess misfit (linear distortion, vertical gap, strains, screw torque). While two human studies evaluated the biological response and technical complications prospectively over 6 and 12 months, the animal studies had an observation period < 12 weeks. Four human studies analysed retrospectively the 3 to 32 years' outcomes. Screw-related complications were observed, but biological sequelae could not be confirmed. Although the animal studies had different designs, bone adaptation and implant displacement was found in histological analyses. Due to the small number of studies and the heterogenic designs and misfit assessment methods, no meta-analysis of the data could be performed. The current literature provides insufficient evidence as to the effect of misfit at the prosthesis-implant interface on clinical outcomes of screw-retained implant-supported fixed dentures. Marginal gaps and static strains due to screw tightening were not found to have negative effects on initial osseointegration or peri-implant bone stability over time. Based on two clinical studies, the risk for technical screw-related complications was slightly higher. While the degree of tolerable misfit remains a matter of debate, the present data do not imply that clinicians neglect good fit, but aim to achieve the least misfit possible. Conflict of interest statement: The authors declare no conflict of interest. The review was conducted as part of the 2016 Foundation of Oral Rehabilitation Consensus Conference on "Prosthetic Protocols in Implant-based Oral Rehabilitation".

  5. Biological and technical complications and failures with fixed partial dentures (FPD) on implants and teeth after four to five years of function.

    PubMed

    Brägger, U; Aeschlimann, S; Bürgin, W; Hämmerle, C H; Lang, N P

    2001-02-01

    The aim of this study was to compare the frequency of biological and technical complications with fixed partial dentures (FPDs) on implants, teeth and as mixed tooth-implant supported FPDs over 4 to 5 years of function. All implants belonged to the ITI Dental Implant System. Group I-I (implant FPD) included 33 patients with 40 FPDs, group T-T (tooth FPDs) 40 patients with 58 FPDs, group I-T (mixed tooth-implant FPDs) 15 with 18 FPD. Of the bridge abutments 144 were teeth and 105 were implants. The median number of units replaced by the FPDs was 3 (range 2-14). The mean age of the patients was 55.7 years (range 23-83). Complete failures resulted in the loss of one FPD in each group. Two implants were lost due to fracture secondarily to development of a bone defect. One tooth had a vertical fracture and 1 tooth was lost due to periodontitis. Biological complications (peri-implantitis, PPD > or = 5 mm and BOP+) occurred at 9.6% (10) of the implants. This number was, however, reduced to 5% if the threshold for definition of peri-implantitis was set at PPD > or = 6 mm and BOP+. Biological complications occurred in 11.8% (17) of the abutment teeth (NS compared to implants); 2.8% (4) had secondary caries, 4.9% (7) endodontic problems and 4.1% (6) had periodontitis (PPD > or = 5 mm, BOP+). Ten out of 32 patients with a general health problem indicated a biological complication, whereas 9 out of 53 patients with no general health problem had a biological complication (chi 2: NS). Statistically significantly more technical complications were found in FPDs on implants (chi 2, P < or = 0.05). The technical complications were associated with bruxism. Out of 10 bruxers 6 had a technical complication whereas 13 out of 75 non-bruxers had such a complication (chi 2 < or = 0.01). Extensions were associated with more technical complications (13 out of 35 with extensions versus 9 out of 81 without). In conclusion, favourable clinical conditions were found at tooth and implant abutments after 4-5 years of function. Loss of FPD over 4-5 years occurred at a similar rate with mixed, implant or tooth supported reconstructions. Significantly more porcelain fractures were found in FPDs on implants. Impaired general health status was not significantly associated with more biological failures but bruxism as well as extensions were associated with more technical failures.

  6. Clinical outcome of double crown-retained implant overdentures with zirconia primary crowns

    PubMed Central

    Buergers, Ralf; Ziebolz, Dirk; Roediger, Matthias

    2015-01-01

    PURPOSE This retrospective study aims at the evaluation of implant-supported overdentures (IODs) supported by ceramo-galvanic double crowns (CGDCs: zirconia primary crowns + galvano-formed secondary crown). MATERIALS AND METHODS In a private practice, 14 patients were restored with 18 IODs (mandible: 11, maxilla: 7) retained by CGDCs on 4 - 8 implants and annually evaluated for technical and/or biological failures/complications. RESULTS One of the 86 inserted implants failed during the healing period (cumulative survival rate (CSR) implants: 98.8%). During the prosthetic functional period (mean: 5.9 ± 2.2 years), 1 implant demonstrated an abutment fracture (CSR-abutments: 98.2%), and one case of peri-implantitis was detected. All IODs remained in function (CSR-denture: 100%). A total of 15 technical complications required interventions to maintain function (technical complication rate: 0.178 treatments/patients/year). CONCLUSION Considering the small sample size, the use of CGDCs for the attachment of IODs is possible without an increased risk of technical complications. However, for a final evaluation, results from a larger cohort are required. PMID:26330981

  7. A review of clinical and technical considerations for fixed and removable implant prostheses in the edentulous mandible.

    PubMed

    Zitzmann, Nicola Ursula; Marinello, Carlo Paolo

    2002-01-01

    The aim of the present article is to review some of the technical treatment options for implant prostheses restoring the edentulous mandible, mainly based on the Brånemark system. Clinical and technical aspects are discussed for the three established concepts: (1) implant-supported fixed prosthesis, (2) removable implant-supported overdenture, and (3) combined implant-retained and soft tissue-supported overdenture prosthesis. The framework of an implant-supported fixed screw-retained prosthesis can be processed in gold, Co-Cr alloy, or titanium with casting, laser-welding, or milling techniques. To improve the stability and retention of a conventional complete denture, one to four implants are indicated, and unsplinted (single attachments) or splinted designs (bar systems) can be applied. The design of the overdenture prosthesis must be carefully planned according to the requirements to ensure adequate stability and optimal form, contour, and esthetics, and the patient's best comfort. A large variety of different treatment modalities exist for both the fixed and removable mandibular implant prosthesis. Clinical and technical aspects should be considered at the beginning of the treatment to: (1) select the optimal implant position, (2) establish an adequate number of functional units, (3) select the appropriate retainers, and (4) apply the best technique for framework processing and veneering.

  8. Minimally Invasive Implantable Fetal Micropacemaker: Mechanical Testing and Technical Refinements

    PubMed Central

    Zhou, Li; Vest, Adriana N.; Peck, Raymond A.; Sredl, Jonathan P.; Huang, Xuechen; Bar-Cohen, Yaniv; Silka, Michael J.; Pruetz, Jay D.; Chmait, Ramen H.; Loeb, Gerald E.

    2016-01-01

    This paper discusses the technical and safety requirements for cardiac pacing of a human fetus with heart failure and hydrops fetalis secondary to complete heart block. Engineering strategies to meet specific technical requirements were integrated into a systematic design and implementation consisting of a novel fetal micropacemaker, a percutaneous implantation system, and a sterile package that enables device storage and recharging maintenance in a clinical setting. We further analyzed observed problems on myocardial fixation and pacing lead fatigue previously reported in earlier preclinical trials. This paper describes the technical refinements of the implantable fetal micropacemaker to overcome these challenges. The mechanical performance has been extensively tested to verify the improvement of reliability and safety margins of the implantation system. PMID:27021067

  9. Fabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview.

    PubMed

    Goo, Chui Ling; Tan, Keson Beng Choon

    2017-01-01

    This report describes the clinical and technical aspects in the oral rehabilitation of an edentulous patient with knife-edge ridge at the mandibular anterior edentulous region, using implant-retained overdentures. The application of computer-aided design and computer-aided manufacturing (CAD/CAM) in the fabrication of the overdenture framework simplifies the laboratory process of the implant prostheses. The Nobel Procera CAD/CAM System was utilised to produce a lightweight titanium overdenture bar with locator attachments. It is proposed that the digital workflow of CAD/CAM milled implant overdenture bar allows us to avoid numerous technical steps and possibility of casting errors involved in the conventional casting of such bars.

  10. Technical complications of implant-causes and management: A comprehensive review

    PubMed Central

    Gupta, Swati; Gupta, Hemant; Tandan, Amrit

    2015-01-01

    Given the increasing popularity of dental implants, the number of failures due to late implant fracture is also expected to increase. Hence, the scope for prevention and management needs to be emphasized. The objective of this review article is to analyze the various causes of failure of dental implants due to implant fixture/abutment screw fractures and also to enumerate the management and the preventive options for these failures, thereby aiming to help the clinicians to properly plan the implant-supported prosthesis treatment by considering the important biomechanical aspects of this type of rehabilitation. The present review emphasizes the causes and management of technical complications and not the incidence of such complications. PMID:26668445

  11. Quality of reporting of descriptive studies in implant dentistry. Critical aspects in design, outcome assessment and clinical relevance.

    PubMed

    Meijer, Henny J A; Raghoebar, Gerry M

    2012-02-01

    The aim of this study was to conduct a review on quality of reporting on descriptive studies in implant dentistry using the STROBE Statement and to analyse possible changes in quality of reporting on descriptive studies in implant dentistry over time. A hand search to select descriptive studies was carried out in seven dental journals, which were thought to have interest in the field of dental implants. Issues of the years 1990, 1995, 2000, 2005 and 2010 were screened. The STROBE Statement with 22 criteria to match was used to determine the quality of an article. Totally 4657 titles and abstracts were screened; 260 of them were found to be reporting on a descriptive study. Percentages of properly addressed items were 46% in 1990, 56% in 1995, 54% in 2000, 59% in 2005 and 70% in 2010. From this review can be concluded that quality of reporting on descriptive studies in implant dentistry is low; there is some improvement from 1990 to 2010, but it does not exceed 70% coverage of the possible to address items. © 2012 John Wiley & Sons A/S.

  12. Deep brain stimulation with a pre-existing cochlear implant: Surgical technique and outcome.

    PubMed

    Eddelman, Daniel; Wewel, Joshua; Wiet, R Mark; Metman, Leo V; Sani, Sepehr

    2017-01-01

    Patients with previously implanted cranial devices pose a special challenge in deep brain stimulation (DBS) surgery. We report the implantation of bilateral DBS leads in a patient with a cochlear implant. Technical nuances and long-term interdevice functionality are presented. A 70-year-old patient with advancing Parkinson's disease and a previously placed cochlear implant for sensorineural hearing loss was referred for placement of bilateral DBS in the subthalamic nucleus (STN). Prior to DBS, the patient underwent surgical removal of the subgaleal cochlear magnet, followed by stereotactic MRI, frame placement, stereotactic computed tomography (CT), and merging of imaging studies. This technique allowed for successful computational merging, MRI-guided targeting, and lead implantation with acceptable accuracy. Formal testing and programming of both the devices were successful without electrical interference. Successful DBS implantation with high resolution MRI-guided targeting is technically feasible in patients with previously implanted cochlear implants by following proper precautions.

  13. Creating and parameterizing patient-specific deep brain stimulation pathway-activation models using the hyperdirect pathway as an example.

    PubMed

    Gunalan, Kabilar; Chaturvedi, Ashutosh; Howell, Bryan; Duchin, Yuval; Lempka, Scott F; Patriat, Remi; Sapiro, Guillermo; Harel, Noam; McIntyre, Cameron C

    2017-01-01

    Deep brain stimulation (DBS) is an established clinical therapy and computational models have played an important role in advancing the technology. Patient-specific DBS models are now common tools in both academic and industrial research, as well as clinical software systems. However, the exact methodology for creating patient-specific DBS models can vary substantially and important technical details are often missing from published reports. Provide a detailed description of the assembly workflow and parameterization of a patient-specific DBS pathway-activation model (PAM) and predict the response of the hyperdirect pathway to clinical stimulation. Integration of multiple software tools (e.g. COMSOL, MATLAB, FSL, NEURON, Python) enables the creation and visualization of a DBS PAM. An example DBS PAM was developed using 7T magnetic resonance imaging data from a single unilaterally implanted patient with Parkinson's disease (PD). This detailed description implements our best computational practices and most elaborate parameterization steps, as defined from over a decade of technical evolution. Pathway recruitment curves and strength-duration relationships highlight the non-linear response of axons to changes in the DBS parameter settings. Parameterization of patient-specific DBS models can be highly detailed and constrained, thereby providing confidence in the simulation predictions, but at the expense of time demanding technical implementation steps. DBS PAMs represent new tools for investigating possible correlations between brain pathway activation patterns and clinical symptom modulation.

  14. Silicone Gel-Filled Breast Implants

    MedlinePlus

    ... and Medical Procedures Implants and Prosthetics Breast Implants Silicone Gel-Filled Breast Implants Share Tweet Linkedin Pin ... sharing options Linkedin Pin it Email Print Description: Silicone gel-filled breast implants have a silicone outer ...

  15. Macro-retentive replaceable veneers on crowns and fixed dental prostheses: a new approach in implant-prosthodontics.

    PubMed

    Schweiger, Josef; Neumeier, Peter; Stimmelmayr, Michael; Beuer, Florian; Edelhoff, Daniel

    2013-04-01

    Implant-supported prosthetic restorations with veneered crowns and fixed dental prostheses are a proven, scientifically accepted treatment concept in fixed prosthodontics. However, in this area of indication there is a comparatively high technical complication rate, which occurs mainly in the area of the superstructure in the form of minor or major chipping of the veneering material. Various studies have shown that purely implant-supported restorations are subjected to higher loading than those on natural abutment teeth due to the special biomechanical conditions. A possible approach to prevent technical complications is to create higher stability for the implant superstructure through the use of high-strength materials. This would, however, result in undiminished overloading being transmitted to the implant components and could cause increased technical and biological complications. This article describes a new procedure for the use of replaceable veneers made from high-performance polymer material on modified implant abutments. By storing digital datasets for the veneer section, it can be replaced easily and quickly if it becomes worn or is fractured. A reduction in the stresses for the implant components and biological structures under the polymer is also to be expected due the material properties of polymers.

  16. Clinical Outcome After 8 to 10 Years of Immediately Restored Single Implants Placed in Extraction Sockets and Healed Ridges.

    PubMed

    Raes, Stefanie; Cosyn, Jan; Noyelle, Anabel; Raes, Filiep; De Bruyn, Hugo

    Recent systematic reviews point to the scarcity of single implants followed up longer than 5 years, and the incidence of biologic/technical complications is underreported. This prospective follow-up study documents 8- to 10-year clinical outcomes of immediately restored single implants in extraction sockets (immediate implant treatment [IIT]) and healed bone (conventional implant treatment [CIT]). Patients received a single, chemically modified, moderately rough titanium implant and a provisional crown on the day of surgery in the anterior maxilla (second premolar to second premolar). Provisional crowns were replaced by permanent crowns after 10 weeks. Implant survival, complications, crestal bone changes, plaque score, probing depth, and bleeding on probing were regularly recorded up to 10 years of follow-up. Of 16 patients who underwent IIT, 11 could be evaluated after 8 years. Of the 23 patients who received an implant in healed bone, 18 were finally evaluated. One implant failed in the IIT group at 12 weeks; all implants survived in the CIT group; 38% of the patients experienced at least one complication; 10% had one or more biologic complications, whereas 31% experienced one or more technical complications. There were no significant changes in crestal bone level from 1 to ≥ 8 years of follow-up for either group or between IIT and CIT at any time point (P ≥ .129). Only 6.9% (2 of 29) implants demonstrated progressive bone loss > 2 mm combined with pockets ≥ 6 mm. Immediately restored single implants in extraction sockets and healed ridges demonstrate good long-term outcomes in terms of implant survival, crestal bone loss, and peri-implant health. However, biologic and especially technical complications are common.

  17. Considerations in computer-aided design for inlay cranioplasty: technical note.

    PubMed

    Nout, Erik; Mommaerts, Maurice Y

    2018-03-01

    Cranioplasty is a frequently performed procedure that uses a variety of reconstruction materials and techniques. In this technical note, we present refinements of computer-aided design-computer-aided manufacturing inlay cranioplasty. In an attempt to decrease complications related to polyether-ether-ketone (PEEK) cranioplasty, we gradually made changes to implant design and cranioplasty techniques. These changes include under-contouring of the implant and the use of segmented plates for large defects, microplate fixation for small temporal defects, temporal shell implants to reconstruct the temporalis muscle, and perforations to facilitate the drainage of blood and cerebrospinal fluid and serve as fixation points. From June 2016 to June 2017, 18 patients underwent cranioplasty, and a total of 31 PEEK and titanium implants were inserted. All implants were successful. These changes to implant design and cranioplasty techniques facilitate the insertion and fixation of patient-specific cranial implants and improve esthetic outcomes.

  18. [Technical complications rates and plaque control of fixed dental prostheses in patients treated for periodontal disease].

    PubMed

    Xie, Yesi; Meng, Huanxin; Han, Jie; Pan, Shaoxia; Zhang, Li; Shi, Dong

    2016-02-01

    To compare the incidence of technical complications of implant-supported fixed dental prostheses in Chinese patients with a history of moderate or severe periodontitis and periodontally healthy patients(PHP) and analyze the effects of interproximal papillae patterns on food impaction and efficacy of plaque control. A total of 103 partially edentulous patients treated with implant-supported fixed dental prostheses between December 2009 and December 2012 for a minimum 1-year follow-up period were recruited from Department of Periodontology, Peking University, School and Hospital of Stomatology. Based on the initial periodontal examination, the participants were divided into three groups: 30 PHP, 36 moderate periodontally compromised patients(mPCP) and 37 severe periodontally compromised patients(sPCP). Implant survival/loss, technical complications, plaque index, papilla index, food impaction and degree of proximal contact tightness of each patient were assessed around the implants at follow-up. According to the implant papilla index, the implants were divided into two groups: the "filling" group with the mesial and distal aspects with papilla index=3 and the "no filling" group with at least one aspect with papilla index<3. Data on implant survival, technical complications were analyzed. Comparisons of the incidence of technical complications were performed between the patients with different periodontal conditions with chi-square or Fisher's exact test. The influences of the interproximal papillae loss on food impaction and efficacy of plaque control were estimated with chi-square and Mann-Whitney U tests. The total implant survival rate was 100%(162/162) for all three groups. Technical complications were as following: veneer fractures(1.9%, 3/162), abutment screw loosening(1.9%, 3/162), prosthetic screw loosening(3.1%, 5/162) and decementation(3.1%, 5/162) in all subjects. No implant/screw fracture was noted. The incidence of technical complications in sPCP, mPCP and PHP did not yield statistically significant differences(P>0.05). The proportion of the implant with the mesial and distal papilla index=3 in the sPCP was less than that in the PHP and mPCP. The interproximal papillae loss did not appear to affect the food impaction and the plaque index in all three groups(P>0.05). However, for the PHP, the accumulation of plaque at buccal aspect was more in the "no filling" group compared with the "filling" group (implant plaque index[M(Q)]: 1[1] vs 0[0]), and for the sPCP, the accumulation of plaque at lingual aspect was more in the "filling" group compared with the "no filling" group(implant plaque index[M(Q)]: 1[1] vs 0[1], (P<0.05). The patients with a history of severe periodontitis did not exhibit more technical problems compared with the periodontally healthy patients. The interproximal papillae loss did not show a negative impact on the plaque control and food impaction. However, for the sPCP, changing the morphology and the position of the interproximal contact point to reduce the interdental black triangle may lead to accumulation of plaque at lingual aspect. More attention should be placed on the morphology design of prosthesis, but not the papillae filling up the interproximal space.

  19. Analysis of professional malpractice claims in implant dentistry in Italy from insurance company technical reports, 2006 to 2010.

    PubMed

    Pinchi, Vilma; Varvara, Giuseppe; Pradella, Francesco; Focardi, Martina; Donati, Michele D; Norelli, Gianaristide

    2014-01-01

    The aim of the study was to analyze the characteristics of implant dentistry claims in Italy based on insurance company technical reports for malpractice claims. One hundred twenty-one technical reports of cases of professional malpractice in implant dentistry between 2006 and 2010 were included in the study. Data included the sex and age of the patient and dentist, the kind of negligence claimed, and the damages awarded as a consequence of the alleged misconduct. Of the cases examined in this study, 9.9% went to court. The patients were female in 73.6% of the cases. Most of the technical errors were committed during implant insertion (82.6%). In 50.4% of cases, the technical error involved the surrounding structures, such as damage to the inferior alveolar nerve (32.2%) or the lingual nerve (2.5%), invasion of the maxillary sinus (9.1%), or pulpal dental necrosis in adjacent teeth (6.6%). Incomplete clinical documentation was apparent in 54.5% of cases. In 9.9% of cases, a civil suit had already been filed before a visit, and medicolegal advice from the insurance expert had been procured. The discrepancy between the total number of cases examined and those that went to court indicates that implant malpractice claims in Italy are most often settled out of court. The large number of intraoperative errors seen and the high proportion of injuries to surrounding structures suggest that implant dentists would benefit from further specific training. Also, clinical documentation vital to a defense against any claims relating to professional misconduct was incomplete or absent in more than half of the cases.

  20. Creating and parameterizing patient-specific deep brain stimulation pathway-activation models using the hyperdirect pathway as an example

    PubMed Central

    Gunalan, Kabilar; Chaturvedi, Ashutosh; Howell, Bryan; Duchin, Yuval; Lempka, Scott F.; Patriat, Remi; Sapiro, Guillermo; Harel, Noam; McIntyre, Cameron C.

    2017-01-01

    Background Deep brain stimulation (DBS) is an established clinical therapy and computational models have played an important role in advancing the technology. Patient-specific DBS models are now common tools in both academic and industrial research, as well as clinical software systems. However, the exact methodology for creating patient-specific DBS models can vary substantially and important technical details are often missing from published reports. Objective Provide a detailed description of the assembly workflow and parameterization of a patient-specific DBS pathway-activation model (PAM) and predict the response of the hyperdirect pathway to clinical stimulation. Methods Integration of multiple software tools (e.g. COMSOL, MATLAB, FSL, NEURON, Python) enables the creation and visualization of a DBS PAM. An example DBS PAM was developed using 7T magnetic resonance imaging data from a single unilaterally implanted patient with Parkinson’s disease (PD). This detailed description implements our best computational practices and most elaborate parameterization steps, as defined from over a decade of technical evolution. Results Pathway recruitment curves and strength-duration relationships highlight the non-linear response of axons to changes in the DBS parameter settings. Conclusion Parameterization of patient-specific DBS models can be highly detailed and constrained, thereby providing confidence in the simulation predictions, but at the expense of time demanding technical implementation steps. DBS PAMs represent new tools for investigating possible correlations between brain pathway activation patterns and clinical symptom modulation. PMID:28441410

  1. Transition from Round to Shaped Implants in Immediate Breast Reconstruction: Our Preferred Approach and Clinical Outcomes.

    PubMed

    Imahiyerobo, Thomas A; Small, Kevin H; Sackeyfio, Robyn; Hoffman, Hannah; Talmor, Mia

    2017-04-01

    Smooth, round, silicone implants predominate device-based breast reconstruction in the USA; despite their prevalence, complications can include bottoming out, superior contour deformity, rippling, and/or lateral malposition. This complication profile increases the need for revision surgery and subsequent patient dissatisfaction. With the resurgence of shaped, textured, silicone implants in the USA, we report the senior author's success with these devices and outline a strategy to optimize outcomes in breast reconstruction surgery. A retrospective chart review was conducted on a prospectively collected IRB-approved database of nipple-sparing mastectomies (NSMs) with immediate breast reconstruction with smooth, round, silicone implants (Group A) in 2011 in comparison to textured, shaped, silicone implants (Group B) in 2012. Changes in operative technique were highlighted and extrapolated. Outcomes were reviewed. In Group A, 128 NSMs were performed in 76 patients. In Group B, 109 NSMs were performed in 59 patients. Thirteen percent of patients in Group A had direct to implant reconstruction as compared with 21% in Group B. Patients with textured, shaped implants were more likely to have acellular dermal matrix (61 vs 34%, p < 0.0001) than those with smooth, round implants. Patients who had smooth, round implants were more likely to have postoperative nipple malposition (18 vs 0%, p < 0.0001,) and rippling (29 vs 0%, p < 0.0001.) Patients with textured, shaped implants had fewer operative revision reconstructions as compared with those with smooth, round implants (36.71 vs 12.8%, p < 0.0001) Based on these results, our technique has evolved and has eight key technical modifications. With a few adaptations in surgical technique, the transition to textured, shaped, silicone devices for breast reconstruction can be seamless with superior breast contour and reduced complications/revision rates. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  2. Effect of implantoplasty on fracture resistance and surface roughness of standard diameter dental implants.

    PubMed

    Costa-Berenguer, Xavier; García-García, Marta; Sánchez-Torres, Alba; Sanz-Alonso, Mariano; Figueiredo, Rui; Valmaseda-Castellón, Eduard

    2018-01-01

    To assess the effect of implantoplasty on the fracture resistance, surface roughness, and macroscopic morphology of standard diameter (4.1 mm) external connection dental implants. An in vitro study was conducted in 20 screw-shaped titanium dental implants with an external connection. In 10 implants, the threads and surface were removed and polished with high-speed burs (implantoplasty), while the remaining 10 implants were used as controls. The final implant dimensions were recorded. The newly polished surface quality was assessed by scanning electron microscopy (SEM) and by 3D surface roughness analysis using a confocal laser microscope. Finally, all the implants were subjected to a mechanical pressure resistance test. A descriptive analysis of the data was made. Also, Student's t tests were employed to detect differences regarding the compression tests. Implantoplasty was carried out for a mean time of 10 min and 48 s (standard deviation (SD) of 1 min 22 s). Macroscopically, the resulting surface had a smooth appearance, although small titanium shavings and silicon debris were present. The final surface roughness (S a values 0.1 ± 0.02 μm) was significantly lower than that of the original (0.75 ± 0.08 μm S a ) (p = .005). There was minimal reduction in the implant's inner body diameter (0.19 ± 0.03 mm), and no statistically significant differences were found between the test and control implants regarding the maximum resistance force (896 vs 880 N, respectively). Implantoplasty, although technically demanding and time-consuming, does not seem to significantly alter fracture resistance of standard diameter external connection implants. A smooth surface with S a values below 0.1 μm can be obtained through the use of silicon polishers. A larger sample is required to confirm that implantoplasty does not significantly affect the maximum resistance force of standard diameter external connection implants. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Frequency of technical complications in fixed implant prosthesis: the effect of prosthesis screw emergence correction by CAD-CAM.

    PubMed

    Anitua, Eduardo; Flores, Carlos; Piñas, Laura; Alkhraisat, Mohammad

    2018-06-05

    CAD-CAM technology permits the angular correction of screw emergence into the prosthesis, however there is lack of controlled clinical studies that assess the frequency of technical complications in angled screw channel restorations. This controlled clinical study was designed to assess technical incidences in angled screw channel restorations. Patients having implant prosthesis placed between November, 2014 and December, 2015 were screened. The patients were selected if they received prosthesis with up to 30º correction of the prosthesis screw emergence and had at least one non-angulated prosthesis (screw-retained). All the prostheses were located completely/partially in the posterior region. The frequency of technical complications was the principal variable. A total of 52 patients with a mean age of 62 ± 10 years participated with a total 110 prostheses (55 in the test group and 55 in the control group). A total of 11 technical complications occurred (7 in the test group and 4 in the control group). These differences were not statistically significant. All the prostheses in both groups survived the follow-up. The correction of the screw emergence into the prosthesis has not increased the risk of technical complications in CAD-CAM implant prostheses.

  4. Use of a Dual Mobility Socket to Manage Total Hip Arthroplasty Instability

    PubMed Central

    Pibarot, Vincent; Vaz, Gualter; Chevillotte, Christophe; Béjui-Hugues, Jacques

    2008-01-01

    Unconstrained tripolar hip implants provide an additional bearing using a mobile polyethylene component between the prosthetic head and the outer metal shell. Such a design increases the effective head diameter and therefore is an attractive option in challenging situations of unstable total hip arthroplasties. We report our experience with 54 patients treated using this dual mobility implant in such situations. We ascertained its ability to restore and maintain stability, and examined component loosening and component failure. At a minimum followup of 2.2 years (mean, 4 years; range, 2.2–6.8 years), one hip had redislocated 2 months postoperatively and was managed successfully without reoperation by closed reduction with no additional dislocation. Two patients required revision of the implant because of dislocation at the inner bearing. Technical errors were responsible for these failures. Three patients had reoperations for deep infections. The postoperative radiographs at latest followup showed very satisfactory osseointegration of the acetabular component because no radiolucent line or osteolysis was reported. Use of this unconstrained tripolar design was successful in restoring and maintaining hip stability. We observed encouraging results at short-term followup regarding potential for loosening or mechanical failures. Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18780135

  5. Sacral root neuromodulation in the treatment of various voiding and storage problems.

    PubMed

    Shaker, H; Hassouna, M M

    1999-01-01

    This paper reviews the use of sacral neuromodulation as a treatment modality for patients with bladder dysfunction. The dual functions of the urinary bladder are to act as a reservoir and to evacuate under voluntary control. Bladder dysfunction is a descriptive term describing the loss or the impairment of one or both of these functions. In the first part of the manuscript we describe the different components of sacral neuromodulation: the screening test known as percutaneous nerve evaluation (PNE), which involves screening patients who could potentially benefit from the therapy. Those who show a satisfactory response will have a permanent neuroprosthesis implanted. The technical aspects of both components of neuromodulation are described in detail, as well as the technical difficulties encountered. In the second part we present our long-term results in patients with sacral neuromodulation. Sacral neuromodulation is a safe and efficient therapeutic modality that helps patients with refractory voiding dysfunction restore their bladder function.

  6. Implantation of programmable infusion pumps for insulin delivery in type I diabetic patients.

    PubMed

    Walter, H; Günther, A; Kronski, D; Flaschenträger, T; Mehnert, H

    1989-06-01

    Five type I diabetic patients were followed prospectively during treatment with continuous subcutaneous insulin infusion by externally worn pumps and during the first 12 months after implantation of a remote-controlled insulin infusion device (ID1, Siemens AG). Stabilized insulin (Hoe 21 GH, Hoechst AG) was infused intravenously in two and intraperitoneally in three patients. Total observation time was 47.2 patient-months after implantation. Two devices had to be explanted prematurely, one because of a technical failure after 101 days, one due to a skin necrosis over the implant after 236 days. HbA1, frequency of hypoglycemia, total insulin dose, and basal rate infusion did not change after implantation. There was a reduction in the insulin antibodies 6 months after start of intravenous or intraperitoneal insulin delivery. Fasting plasma free insulin levels could be normalized only by intraperitoneal insulin infusion. Although a technical and a surgical problem was observed, our data show the successful implantation and clinical use of programmable dosing devices and stabilized insulin.

  7. Virtual Preoperative Planning and Intraoperative Navigation in Facial Prosthetic Reconstruction: A Technical Note.

    PubMed

    Verma, Suzanne; Gonzalez, Marianela; Schow, Sterling R; Triplett, R Gilbert

    This technical protocol outlines the use of computer-assisted image-guided technology for the preoperative planning and intraoperative procedures involved in implant-retained facial prosthetic treatment. A contributing factor for a successful prosthetic restoration is accurate preoperative planning to identify prosthetically driven implant locations that maximize bone contact and enhance cosmetic outcomes. Navigational systems virtually transfer precise digital planning into the operative field for placing implants to support prosthetic restorations. In this protocol, there is no need to construct a physical, and sometimes inaccurate, surgical guide. The report addresses treatment workflow, radiologic data specifications, and special considerations in data acquisition, virtual preoperative planning, and intraoperative navigation for the prosthetic reconstruction of unilateral, bilateral, and midface defects. Utilization of this protocol for the planning and surgical placement of craniofacial bone-anchored implants allows positioning of implants to be prosthetically driven, accurate, precise, and efficient, and leads to a more predictable treatment outcome.

  8. In vitro evaluation of a passive radio frequency identification microchip implanted in human molars subjected to compression forces, for forensic purposes of human identification

    PubMed Central

    Moreno, Freddy; Vallejo, Diego; Garzón, Herney; Moreno, Sandra

    2013-01-01

    Objective: To evaluate the in vitro behavior of a passive Radio Frequency Identification (RFID) microchip implanted in human molars subjected to compression forces to determine its technical and clinical viability. Materials and Methods: In vitro experimental study to evaluate the physical behavior of a passive RFID microchip (VeriChip™) implanted in human molars through resin restoration (Filtek P90™ Silorane 3M-ESPE®) to determine the clinical and technical possibilities of the implant and the viability to withstand compression forces exerted by the stomatognathic system during mastication. Results: Through the ANOVA test, it was found that the teeth on which a microchip was implanted show great resistance to compressive forces. It was also evident that teeth with microchips implanted in Class V cavities are more resistant than those implanted in Class I cavities. Conclusions: Although microchip dimensions are big, requiring a sufficiently large cavity, from the biomechanical point of view it is plausible to implant a microchip in a Class V cavity employing restoration material based on resin for forensic purposes of human identification. PMID:24255554

  9. A minimally invasive technique for percutaneous lumbar facet augmentation: Technical description of a novel device

    PubMed Central

    Smith, Zachary A.; Armin, Sean; Raphael, Dan; Khoo, Larry T.

    2011-01-01

    Background: We describe a new posterior dynamic stabilizing system that can be used to augment the mechanics of the degenerating lumbar segment. The mechanism of this system differs from other previously described surgical techniques that have been designed to augment lumbar biomechanics. The implant and technique we describe is an extension-limiting one, and it is designed to support and cushion the facet complex. Furthermore, it is inserted through an entirely percutaneous technique. The purpose of this technical note is to demonstrate a novel posterior surgical approach for the treatment of lumbar degenerative. Methods: This report describes a novel, percutaneously placed, posterior dynamic stabilization system as an alternative option to treat lumbar degenerative disk disease with and without lumbar spinal stenosis. The system does not require a midline soft-tissue dissection, nor subperiosteal dissection, and is a truly minimally invasive means for posterior augmentation of the functional facet complex. This system can be implanted as a stand-alone procedure or in conjunction with decompression procedures. Results: One-year clinical results in nine individual patients, all treated for degenerative disease of the lower lumbar spine, are presented. Conclusions: This novel technique allows for percutaneous posterior dynamic stabilization of the lumbar facet complex. The use of this procedure may allow a less invasive alternative to traditional approaches to the lumbar spine as well as an alternative to other newly developed posterior dynamic stabilization systems. PMID:22145084

  10. Complications with computer-aided designed/computer-assisted manufactured titanium and soldered gold bars for mandibular implant-overdentures: short-term observations.

    PubMed

    Katsoulis, Joannis; Wälchli, Julia; Kobel, Simone; Gholami, Hadi; Mericske-Stern, Regina

    2015-01-01

    Implant-overdentures supported by rigid bars provide stability in the edentulous atrophic mandible. However, fractures of solder joints and matrices, and loosening of screws and matrices were observed with soldered gold bars (G-bars). Computer-aided designed/computer-assisted manufactured (CAD/CAM) titanium bars (Ti-bars) may reduce technical complications due to enhanced material quality. To compare prosthetic-technical maintenance service of mandibular implant-overdentures supported by CAD/CAM Ti-bar and soldered G-bar. Edentulous patients were consecutively admitted for implant-prosthodontic treatment with a maxillary complete denture and a mandibular implant-overdenture connected to a rigid G-bar or Ti-bar. Maintenance service and problems with the implant-retention device complex and the prosthesis were recorded during minimally 3-4 years. Annual peri-implant crestal bone level changes (ΔBIC) were radiographically assessed. Data of 213 edentulous patients (mean age 68 ± 10 years), who had received a total of 477 tapered implants, were available. Ti-bar and G-bar comprised 101 and 112 patients with 231 and 246 implants, respectively. Ti-bar mostly exhibited distal bar extensions (96%) compared to 34% of G-bar (p < .001). Fracture rate of bars extensions (4.7% vs 14.8%, p < .001) and matrices (1% vs 13%, p < .001) was lower for Ti-bar. Matrices activation was required 2.4× less often in Ti-bar. ΔBIC remained stable for both groups. Implant overdentures supported by soldered gold bars or milled CAD/CAM Ti-bars are a successful treatment modality but require regular maintenance service. These short-term observations support the hypothesis that CAD/CAM Ti-bars reduce technical complications. Fracture location indicated that the titanium thickness around the screw-access hole should be increased. © 2013 Wiley Periodicals, Inc.

  11. The Monorail Technique to Overcome Difficult Anatomical Course During Implantation of Central Venous Port via the Left Internal Jugular Vein

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Eu Hyun, E-mail: doorihyun6@gmail.com; Oh, Jung Suk; Chun, Ho Jong

    PurposeThe study aimed to introduce a monorail technique to overcome difficult anatomical course via left internal jugular vein in implantable port insertion.MethodsFrom 2007 to 2016, a total of 9346 patients were referred for implantable port insertion in our interventional unit, among which 79 cases were requested to insert on the left side. Our monorail technique was applied only when the technical challenge of the catheter tip entering the azygos vein instead of the superior vena cava occurred (n = 7). The technique consists of puncturing at the distal tip of the port catheter with a 21-gauge micropuncture needle and advancing a 0.018-in.more » hair-wire to guide and provide support for pre-assembled port.ResultsThe monorail technique was performed in seven patients and all but one case were technically successful, showing a technical success rate of 85.7%. There were no immediate or delayed complications.ConclusionsThe monorail technique is helpful to overcome the difficult anatomical course via left internal jugular vein in implantable port insertion.« less

  12. The Monorail Technique to Overcome Difficult Anatomical Course During Implantation of Central Venous Port via the Left Internal Jugular Vein.

    PubMed

    Kim, Eu Hyun; Oh, Jung Suk; Chun, Ho Jong; Lee, Hae Giu; Choi, Byung Gil

    2017-03-01

    The study aimed to introduce a monorail technique to overcome difficult anatomical course via left internal jugular vein in implantable port insertion. From 2007 to 2016, a total of 9346 patients were referred for implantable port insertion in our interventional unit, among which 79 cases were requested to insert on the left side. Our monorail technique was applied only when the technical challenge of the catheter tip entering the azygos vein instead of the superior vena cava occurred (n = 7). The technique consists of puncturing at the distal tip of the port catheter with a 21-gauge micropuncture needle and advancing a 0.018-in. hair-wire to guide and provide support for pre-assembled port. The monorail technique was performed in seven patients and all but one case were technically successful, showing a technical success rate of 85.7%. There were no immediate or delayed complications. The monorail technique is helpful to overcome the difficult anatomical course via left internal jugular vein in implantable port insertion.

  13. Multifractal spectrum and lacunarity as measures of complexity of osseointegration.

    PubMed

    de Souza Santos, Daniel; Dos Santos, Leonardo Cavalcanti Bezerra; de Albuquerque Tavares Carvalho, Alessandra; Leão, Jair Carneiro; Delrieux, Claudio; Stosic, Tatijana; Stosic, Borko

    2016-07-01

    The goal of this study is to contribute to a better quantitative description of the early stages of osseointegration, by application of fractal, multifractal, and lacunarity analysis. Fractal, multifractal, and lacunarity analysis are performed on scanning electron microscopy (SEM) images of titanium implants that were first subjected to different treatment combinations of i) sand blasting, ii) acid etching, and iii) exposition to calcium phosphate, and were then submersed in a simulated body fluid (SBF) for 30 days. All the three numerical techniques are applied to the implant SEM images before and after SBF immersion, in order to provide a comprehensive set of common quantitative descriptors. It is found that implants subjected to different physicochemical treatments before submersion in SBF exhibit a rather similar level of complexity, while the great variety of crystal forms after SBF submersion reveals rather different quantitative measures (reflecting complexity), for different treatments. In particular, it is found that acid treatment, in most combinations with the other considered treatments, leads to a higher fractal dimension (more uniform distribution of crystals), lower lacunarity (lesser variation in gap sizes), and narrowing of the multifractal spectrum (smaller fluctuations on different scales). The current quantitative description has shown the capacity to capture the main features of complex images of implant surfaces, for several different treatments. Such quantitative description should provide a fundamental tool for future large scale systematic studies, considering the large variety of possible implant treatments and their combinations. Quantitative description of early stages of osseointegration on titanium implants with different treatments should help develop a better understanding of this phenomenon, in general, and provide basis for further systematic experimental studies. Clinical practice should benefit from such studies in the long term, by more ready access to implants of higher quality.

  14. Immediate Placement of Ultrawide-Diameter Implants in Molar Sockets: Description of a Recommended Technique.

    PubMed

    Hattingh, André C; De Bruyn, Hugo; Ackermann, Andrew; Vandeweghe, Stefan

    Immediate implant placement is performed less frequently in molar extraction sockets than in single root sockets. This is mainly due to the tripodal anatomical configuration of molar roots, which is perceived as complex and therefore unsuitable. The mechanical burden of molar sites, combined with much larger socket dimensions, make it amenable to the use of ultrawide-diameter dental implants. This article describes a practical, sequenced technique that can be used predictably for immediate implant placement in maxillary and mandibular first molar sockets, using a dry skull model for clarification. This detailed description is based on the experience of more than 580 clinical cases over a 10-year period.

  15. Transfemoral aortic valve implantation in severe aortic stenosis patients with prior mitral valve prosthesis

    PubMed Central

    Sarı, Cenk; Baştuğ, Serdal; Kasapkara, Hacı Ahmet; Durmaz, Tahir; Keleş, Telat; Akçay, Murat; Aslan, Abdullah Nabi; Bayram, Nihal Akar; Bozkurt, Engin

    2015-01-01

    Introduction Transcatheter aortic valve implantation for severe symptomatic aortic stenosis in patients with a previous mitral valve prosthesis is technically challenging, and pre-procedural comprehensive assessment of these patients before transcatheter aortic valve implantation is vital for an uncomplicated and successful procedure. Aim We want to share our experience with transcatheter aortic valve implantation in patients with a preexisting functional mitral valve prosthesis and describe a series of important technical and pre-procedural details. Material and methods At our center, 135 patients with symptomatic severe aortic stenosis were treated with transcatheter aortic valve implantation. Six of them with a preexisting mitral valve prosthesis received an Edwards SAPIEN XT valve through the transfemoral route. Results Transcatheter aortic valve implantation was performed successfully in all 6 patients without any deformation of the cobalt-chromium/steel stents of the aortic valve bioprosthesis. Also no distortion or malfunction in the mitral valve prosthesis was observed after the procedure. There were no complications during the hospitalization period. Post-procedural echocardiography revealed no or mild aortic paravalvular regurgitation and normal valve function in all the patients. In addition, serial echocardiographic examination demonstrated that both the stability and function of the aortic and mitral prosthetic valves were normal without any deterioration in the gradients and the degree of the regurgitation at long-term follow-ups. Conclusions Our experience confirms that transcatheter aortic valve implantation is technically feasible in patients with previous mitral valve replacement but comprehensive evaluation of patients by multimodal imaging techniques such as transesophageal echocardiography and multislice computed tomography is mandatory for a successful and safe procedure. PMID:26677380

  16. How to treat two adjacent missing teeth with dental implants. A systematic review on single implant-supported two-unit cantilever FDP's and results of a 5-year prospective comparative study in the aesthetic zone.

    PubMed

    Van Nimwegen, W G; Raghoebar, G M; Tymstra, N; Vissink, A; Meijer, H J A

    2017-06-01

    To conduct a systematic review on the clinical outcome of single implant-supported two-unit cantilever FDP's and to conduct a 5-year prospective comparative pilot study of patients with a missing central and lateral upper incisor treated with either a single implant-supported two-unit cantilever FDP or two implants with solitary implant crowns in the aesthetic zone. Medline, Embase and the Cochrane Central Register of Controlled Trials were searched (last search 1 August 2016) for eligible studies. In the comparative pilot study, an implant-cantilever group of five patients with a single implant-supported two-unit cantilever FDP (NobelReplace Groovy Regular Platform) was compared with an implant-implant group of five patients with two adjacent single implant-supported crowns (NobelReplace Groovy Regular Platform) in the aesthetic zone. Implant survival, marginal bone level (MBL) changes, pocket probing depth, papilla index and patient satisfaction were assessed during a 5-year follow-up period. Five of 276 articles were considered eligible for data extraction. Implant survival ranged from 96·6% to 100%. Marginal bone level changes were higher in the anterior region than in the posterior region. Technical complications occurred more often in the posterior than anterior region. In the 5-year comparative pilot study, no clinically significant differences in hard and soft peri-implant tissue levels occurred between both groups. Single implant-supported two-unit cantilever FDP's can be a viable alternative to the placement of two adjacent single implant crowns in the aesthetic zone. Due to technical complications, placement of two-unit cantilever crowns in the posterior region can be considered unwise. © 2017 John Wiley & Sons Ltd.

  17. Women with silicone breast implants and autoimmune inflammatory syndrome induced by adjuvants: description of three patients and a critical review of the literature.

    PubMed

    Pavlov-Dolijanovic, Slavica; Vujasinovic Stupar, Nada

    2017-08-01

    Silicone has been widely used in the manufacture of medical implants. It is well tolerated in most cases. However, in this paper we report the cases of three women who developed autoimmune/inflammatory syndrome induced by adjuvants (ASIA syndrome), namely with silicone breast implants. The symptoms in these cases include arthralgia, arthritis, myalgia, sleep disturbances, the appearance of autoantibodies, miscarriage, Raynaud's phenomenon, and involvement of autoimmune diseases (scleroderma and undifferentiated connective tissue diseases). In one patient, breast implants were removed, but no improvement was seen after the removal. The remaining two patients received the updated information about their condition, and they decided not to remove the implants. In conclusion, earlier reports that silicone is biologically relatively inert have recently been challenged with the description of ASIA syndrome.

  18. Latest technologic and surgical developments in using InterStim Therapy for sacral neuromodulation: impact on treatment success and safety.

    PubMed

    Spinelli, Michele; Sievert, Karl-Dietrich

    2008-12-01

    This article accompanies a "surgery in motion" DVD on sacral neuromodulation (SNM) with InterStim Therapy, which visualizes the implantation of the InterStim II system. The article describes the technical and surgical developments of SNM and their impact on treatment success, safety, and patient's quality of life (QoL). Relevant literature on SNM with regard to technical changes and related clinical outcomes has been reviewed. Since its introduction in the early 1990s, SNM has proven useful in the treatment of several types of chronic urinary (and bowel) dysfunction. Recent technical improvements in devices and, in particular, the introduction of the tined lead 5 yr ago made SNM progress from an elaborate, open-surgery, general anesthesia, one-stage implant procedure to a minimally invasive, local anesthesia, percutaneous technique in two stages. The permanent tined lead implant enables a longer patient testing period (minimum of 14 d recommended) and less lead migration. This has considerably reduced technical failures and improved the success rate of the test phase; the response rate was almost doubled to approximately 80%. These improvements also affected tolerability, resulting in increased QoL for the patient. The use of the recently introduced smaller implantable neurostimulator InterStim II seems to further improve patient comfort and makes the implant procedure for the physician easier and shorter. However, this must be further addressed in clinical studies. SNM with InterStim Therapy using the tined lead offers an efficient treatment modality for patients in whom conservative treatment has failed.

  19. Prospective assessment of CAD/CAM zirconia abutment and lithium disilicate crown restorations: 2.4 year results.

    PubMed

    Cooper, Lyndon F; Stanford, Clark; Feine, Jocelyne; McGuire, Michael

    2016-07-01

    Single-tooth implant restorations are commonly used to replace anterior maxillary teeth. The esthetic, functional, and biologic outcomes are, in part, a function of the abutment and crown. The purpose of this clinical study was to describe the implant, abutment, and crown survival and complication rates for CAD/CAM zirconia abutment and lithium disilicate crown restorations for single-tooth implants. As part of a broader prospective investigation that enrolled and treated 141 participants comparing tissue responses at the conical interface (CI; AstraTech OsseoSpeed), flat-to-flat interface (FI; NobelSpeedy), and platform-switch interface (PS; NanoTite Certain Prevail) of single-tooth implants, computer-aided design and computer-aided manufacturing (CAD/CAM) zirconia abutments (ATLANTIS Abutment) and cemented lithium disilicate (e.max) crowns were used in the restoration of all implants. After 2.4 years in function (3 years after implant placement), the implant, abutment, and crown of 110 participants were evaluated. Technical and biologic complications were recorded. Demographic results were tabulated as percentages with mean values and standard deviations. Abutment survival was calculated with the Kaplan-Meier method. After 2.4 years, no abutments or crowns had been lost. Abutment complications (screw loosening, screw fracture, fracture) were absent for all 3 implant groups. Crown complications were limited to 2 crowns debonding and 1 with excess cement (2.5%). Five biological complications (4.0%) were recorded. The overall complication rate was 6.5%. CAD/CAM zirconia abutments restored with cemented lithium disilicate crowns demonstrated high survival on 3 different implant-abutment interface designs. No abutment or abutment screw fracture occurred. The technical complications observed after 2.4 years were minor and reversible. The use of CAD/CAM zirconia abutments with cemented lithium disilicate crowns is associated with high technical and biologic success at 2.4 years. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. Impact of graft implantation order on graft survival in simultaneous pancreas-kidney transplantation.

    PubMed

    Niclauss, Nadja; Bédat, Benoît; Morel, Philippe; Andres, Axel; Toso, Christian; Berney, Thierry

    2016-05-01

    The optimal order of revascularization for pancreas and kidney grafts in simultaneous pancreas-kidney transplantation has not been established. In this study, we investigate the influence of graft implantation order on graft survival in SPK. 12 700 transplantations from the Scientific Registry of Transplant Recipients were analyzed retrospectively. Graft implantation order was determined based on the reported ischemia times of pancreas and kidney grafts. Pancreas and kidney graft survivals were analyzed depending on graft implantation order at 3 months and 5 years using Kaplan-Meier plots. Significance was tested with log-rank test and Cox regression model. In 8454 transplantations, the pancreas was implanted first (PBK), and in 4246 transplantations, the kidney was implanted first (KBP). The proportion of lost pancreas grafts at 3 months was significantly lower in PBK (9.4% vs. 10.8%, P = 0.011). Increasing time lag (>2 h) between kidney and pancreas graft implantation in KBP accentuated the detrimental impact on pancreas graft survival (12.5% graft loss at 3 months, P = 0.001). Technical failure rates were reduced in PBK (5.6 vs. 6.9%, P = 0.005). Graft implantation order had no impact on kidney graft survival. In summary, although observed differences are small, pancreas graft implantation first increases short-term pancreas graft survival and reduces rates of technical failure. © 2016 Steunstichting ESOT.

  1. Clinical outcome of narrow-diameter (3.3-mm) locking-taper implants: a prospective study with 1 to 10 years of follow-up.

    PubMed

    Mangano, Francesco; Shibli, Jamil A; Sammons, Rachel L; Veronesi, Giovanni; Piattelli, Adriano; Mangano, Carlo

    2014-01-01

    To evaluate the outcome of narrow-diameter (3.3-mm) locking-taper implants used in the rehabilitation of partially and fully edentulous patients over a 10-year period. Between January 2002 and December 2011, all patients referred to a private dental clinic for treatment with narrow-diameter implants were enrolled in this study. At each annual follow-up session, clinical and radiographic parameters were assessed; the outcome measurements were implant failure, peri-implant marginal bone loss (distance between the implant shoulder and the first visible bone-to-implant contact [DIB]), and biologic and technical complications. The cumulative survival rate (CSR) was assessed using the Kaplan-Meier survival estimator; Tarone-Ware and chi-square analyses were used to evaluate correlations between the study variables. The statistical analysis was performed at the patient- and implant-level. A total of 324 narrow-diameter implants were placed in 279 patients (159 men, 120 women; age: 25 to 73 years). Four implants failed, for an overall CSR of 98.5% (patient-based) and 98.7% (implant-based) at the 10-year follow-up. The survival rate did not differ significantly with respect to patients' sex, age, smoking or parafunctional habits, bone type, prosthetic restoration, or implant location, position, or length. Among the surviving implants, a mean DIB of 0.31 ± 0.23 mm, 0.45 ± 0.27 mm, and 0.69 ± 0.28 mm was observed at the 1-, 5-, and 10-year follow-up examinations, respectively. A few biologic (1.2%) and technical complications (7.5%) were reported. Within the limitations of this study, it can be concluded that narrow-diameter locking-taper implants represent a good treatment option for the prosthetic rehabilitation of partially and totally edentulous patients.

  2. The effect of rigid and non-rigid connections between implants and teeth on biological and technical complications: a systematic review and a meta-analysis.

    PubMed

    Tsaousoglou, Phoebus; Michalakis, Konstantinos; Kang, Kiho; Weber, Hans-Peter; Sculean, Anton

    2017-07-01

    To assess survival, as well as technical and biological complication rates of partial fixed dental prostheses (FDPs) supported by implants and teeth. An electronic Medline search was conducted to identify articles, published in dental journals from January 1980 to August 2015, reporting on partial FDPs supported by implants and teeth. The search terms were categorized into four groups comprising the PICO question. Manual searches of published full-text articles and related reviews were also performed. The initial database search produced 3587 relevant titles. Three hundred and eighty-six articles were retrieved for abstract review, while 39 articles were selected for full-text review. A total of 10 studies were selected for inclusion. Overall survival rate for implants ranged between 90% and 100%, after follow-up periods with a mean range of 18-120 months. The survival of the abutment teeth was 94.1-100%, while the prostheses survival was 85-100% for the same time period. The most frequent complications were "periapical lesions" (11.53%). The most frequent technical complication was "porcelain occlusal fracture" (16.6%), followed by "screw loosening" (15%). According to the meta-analysis, no intrusion was noted on the rigid connection group, while five teeth (8.19%) were intruded in the non-rigid connection group [95% CI (0.013-0.151)]. The tooth-implant FDP seems to be a possible alternative to an implant-supported FDP. There is limited evidence that rigid connection between teeth and implants presents better results when compared with the non-rigid one. The major drawback of non-rigidly connected FDPs is tooth intrusion. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goltz, Jan P., E-mail: Goltz@roentgen.uni-wuerzburg.de; Scholl, Anne; Ritter, Christian O.

    The aim of this study is to evaluate the effectiveness and safety of percutaneously placed totally implantable venous-access ports (TIVAPs) of the forearm. Between January 2006 and October 2008, peripheral TIVAPs were implanted in 763 consecutive patients by ultrasound and fluoroscopic guidance. All catheters were implanted under local anesthesia and were tunneled subcutaneously. Indication, technical success, and complications were retrospectively analyzed according to Society of Interventional Radiology (SIR) criteria. Presence of antibiotic prophylaxis, periprocedurally administered drugs (e.g., sedation), and laboratory results at the time of implantation were analyzed. Maintenance during the service interval was evaluated. In total, 327,499 catheter-days weremore » analyzed. Technical success rate was 99.3%. Reasons for initial failure of implantation were either unexpected thrombosis of the subclavian vein, expanding tumor mass of the mediastinum, or failure of peripheral venous access due to fragile vessels. Mean follow-up was 430 days. There were 115 complications observed (15.1%, 0.03 per 100 catheter-days), of which 33 (4.3%) were classified as early (within 30 days from implantation) and 82 (10.7%) as late. Catheter-related venous thrombosis was found in 65 (8.5%) of 763 (0.02 per 100 catheter-days) TIVAPs. Infections were observed in 41 (5.4%) of 763 (0.01 per 100 catheter-days) devices. Other complications observed included dislocation of the catheter tip (0.8%), occlusion (0.1%), or rupture (0.1%) of the port catheter. Dislocated catheters were corrected during a second interventional procedure. In conclusion, implantation of percutaneously placed peripheral TIVAPs shows a high technical success rate and low risk of early complications when ultrasound and fluoroscopic guidance are used. Late complications are observed three times as often as early complications.« less

  4. What Does Music Sound Like for a Cochlear Implant User?

    PubMed

    Jiam, Nicole T; Caldwell, Meredith T; Limb, Charles J

    2017-09-01

    Cochlear implant research and product development over the past 40 years have been heavily focused on speech comprehension with little emphasis on music listening and enjoyment. The relatively little understanding of how music sounds in a cochlear implant user stands in stark contrast to the overall degree of importance the public places on music and quality of life. The purpose of this article is to describe what music sounds like to cochlear implant users, using a combination of existing research studies and listener descriptions. We examined the published literature on music perception in cochlear implant users, particularly postlingual cochlear implant users, with an emphasis on the primary elements of music and recorded music. Additionally, we administered an informal survey to cochlear implant users to gather first-hand descriptions of music listening experience and satisfaction from the cochlear implant population. Limitations in cochlear implant technology lead to a music listening experience that is significantly distorted compared with that of normal hearing listeners. On the basis of many studies and sources, we describe how music is frequently perceived as out-of-tune, dissonant, indistinct, emotionless, and weak in bass frequencies, especially for postlingual cochlear implant users-which may in part explain why music enjoyment and participation levels are lower after implantation. Additionally, cochlear implant users report difficulty in specific musical contexts based on factors including but not limited to genre, presence of lyrics, timbres (woodwinds, brass, instrument families), and complexity of the perceived music. Future research and cochlear implant development should target these areas as parameters for improvement in cochlear implant-mediated music perception.

  5. Height parallelism of implants in the treatment of the edentulous mandible with ball-retained overdentures: a technical note.

    PubMed

    Iglesia-Puig, Miguel A

    2008-01-01

    The objective of this report is to present a device to achieve equal platform height in the vertical axis to allow the spherical abutments to work correctly in mandibular overdentures retained with 2 implants. The device is fabricated over plastic castable abutments, with a plate perpendicular to the implant platforms and located at the top of the platform height. Once implants are inserted, the device is screwed to an implant and allows evaluation of the height of the platforms.

  6. Current requirements for polymeric biomaterials in otolaryngology

    PubMed Central

    Sternberg, Katrin

    2011-01-01

    In recent years otolaryngology was strongly influenced by newly developed implants which are based on both, innovative biomaterials and novel implant technologies. Since the biomaterials are integrated into biological systems they have to fulfill all technical requirements and accommodate biological interactions. Technical functionality relating to implant specific mechanical properties, a sufficiently high stability in terms of physiological conditions, and good biocompatibility are the demands with regard to suitability of biomaterials. The goal in applying biomaterials for implants is to maintain biofunctionality over extended periods of time. These general demands to biomaterials are equally valid for use in otolaryngology. Different classes of materials can be utilized as biomaterials. Metals belong to the oldest biomaterials. In addition, alloys, ceramics, inorganic glasses and composites have been tested successfully. Furthermore, natural and synthetic polymers are widely used materials, which will be in the focus of the current article with regard to their properties and usage as cochlear implants, osteosynthesis implants, stents, and matrices for tissue engineering. Due to their application as permanent or temporary implants materials are differentiated into biostable and biodegradable polymers. The here identified general and up to date requirements for biomaterials and the illustrated applications in otolaryngology emphasize ongoing research efforts in this area and at the same time demonstrate the high significance of interdisciplinary cooperation between natural sciences, engineering, and medical sciences. PMID:22073104

  7. Endovascular stent-based revascularization of malignant superior vena cava syndrome with concomitant implantation of a port device using a dual venous approach.

    PubMed

    Anton, Susanne; Oechtering, T; Stahlberg, E; Jacob, F; Kleemann, M; Barkhausen, J; Goltz, J P

    2018-06-01

    The aim of this paper is to evaluate the safety and efficacy of endovascular revascularization of malignant superior vena cava syndrome (SVCS) and simultaneous implantation of a totally implantable venous access port (TIVAP) using a dual venous approach. Retrospectively, 31 patients (mean age 67 ± 8 years) with malignant CVO who had undergone revascularization by implantation of a self-expanding stent into the superior vena cava (SVC) (Sinus XL®, OptiMed, Germany; n = 11 [Group1] and Protégé ™ EverFlex, Covidien, Ireland; n = 20 [Group 2]) via a transfemoral access were identified. Simultaneously, percutaneous access via a subclavian vein was used to (a) probe the lesion from above, (b) facilitate a through-and-through maneuver, and (c) implant a TIVAP. Primary endpoints with regard to the SVC syndrome were technical (residual stenosis < 30%) and clinical (relief of symptoms) success; with regard to TIVAP implantation technical success was defined as positioning of the functional catheter within the SVC. Secondary endpoints were complications as well as stent and TIVAP patency. Technical and clinical success rate were 100% for revascularization of the SVS and 100% for implantation of the TIVAP. One access site hematoma (minor complication, day 2) and one port-catheter-associated sepsis (major complication, day 18) were identified. Mean catheter days were 313 ± 370 days. Mean imaging follow-up was 184 ± 172 days. Estimated patency rates at 3, 6, and 12 months were 100% in Group 1 and 84, 84, and 56% in Group 2 (p = 0.338). Stent-based revascularization of malignant SVCS with concomitant implantation of a port device using a dual venous approach appears to be safe and effective.

  8. Biofilm on dental implants: a review of the literature.

    PubMed

    Subramani, Karthikeyan; Jung, Ronald E; Molenberg, Aart; Hammerle, Christoph H F

    2009-01-01

    The aim of this article was to review the current literature with regard to biofilm formation on dental implants and the influence of surface characteristics (chemistry, surface free energy, and roughness) of dental implant and abutment materials and their design features on biofilm formation and its sequelae. An electronic MEDLINE literature search was conducted of studies published between 1966 and June 2007. The following search terms were used: biofilm and dental implants, biofilm formation/plaque bacterial adhesion and implants, plaque/biofilm and surface characteristics/roughness/surface free energy of titanium dental implants, implant-abutment interface and plaque/biofilm, biofilm and supragingival/subgingival plaque microbiology, biofilm/plaque and implant infection, antibacterial/bacteriostatic titanium, titanium nanocoating/nanopatterning, antimicrobial drug/titanium implant. Both in vitro and in vivo studies were included in this review. Fifty-three articles were identified in this review process. The articles were categorized with respect to their context on biofilm formation on teeth and dental implant surfaces and with regard to the influence of surface characteristics of implant biomaterials (especially titanium) and design features of implant and abutment components on biofilm formation. The current state of literature is more descriptive, rather than providing strong data that could be analyzed through meta-analysis. Basic research articles on surface modification of titanium were also included in the review to analyze the applications of such studies on the fabrication of implant surfaces that could possibly decrease early bacterial colonization and biofilm formation. Increase in surface roughness and surface free energy facilitates biofilm formation on dental implant and abutment surfaces, although this conclusion is derived from largely descriptive literature. Surface chemistry and the design features of the implant-abutment configuration also play a significant role in biofilm formation.

  9. Reverse-Muscle Sling Reduces Complications in Revisional Mastopexy-Augmentation.

    PubMed

    Valente, Denis Souto

    2018-06-20

    Simultaneous augmentation-mastopexy is a particularly tricky operation with a considerable reoperation rate. The pectoralis muscle sling has proven to be a suitable alternative technique for long-term results in breast parenchyma suspension without silicone implants. This study aims to propose a promising approach to simultaneous augmentation-mastopexy revisional surgery using an inverted dual-plane technique acting as a muscular sling. A 10-year historic cohort was conducted to obtain the following variables from our preexisting database: age, preoperative measurements, operative technicalities, implant details, time from procedure to revision, complications, and outcomes. Twenty-six patients assessed after the initial postoperative year were analyzed. Review of this series of patients revealed a revision rate of 3.8% and overall rate of morbidity of 11.5%. Simultaneous augmentation-mastopexy using an inverted dual-plane technique acting as a muscular sling is a reliable and safe procedure. Review of this series of patients revealed low rates of morbidity and reoperation need. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  10. Music Perception of Cochlear Implant Recipients with Implications for Music Instruction: A Review of Literature

    PubMed Central

    Hsiao, Feilin; Gfeller, Kate

    2013-01-01

    This review of literature presents a systematic analysis of the capabilities and limitations of cochlear implant recipients regarding music perception. Specifically, it a) analyzes individual components of music (e.g., rhythm, timbre, and pitch) as they interface with the technical characteristics of cochlear implants and the perceptual abilities of cochlear implant recipients; and b) describes accommodations for music instruction that support successful participation of children with cochlear implants. This article consolidates research studies from various disciplines (audiology, hearing science, speech-language pathology, cochlear implants, and music therapy) to provide practical recommendations for educators in fostering the musical growth of children with cochlear implants. PMID:23469365

  11. Efficacy Study of a Fully Implanted Neuroprosthesis for Functional Benefit to Individuals with Tetraplegia

    DTIC Science & Technology

    2016-10-01

    platysma muscle (top red) and trapezius muscle (bottom blue). Bottom Clamshell Side View Cooled water flows through tubing Rubber Tubing Plastic...Enclosure Top View Top Clamshell Top View Side View Top View Cooled water flows through tubing Rubber Tubing Plastic Enclosure Figure 3. Descriptive...typical of the uptake of implanted neuromodulation devices [e.g. cochlear implants, bladder implants, hand neuroprosthesis]. This approach maximizes

  12. Improvements in implant dentistry over the last decade: comparison of survival and complication rates in older and newer publications.

    PubMed

    Pjetursson, Bjarni E; Asgeirsson, Asgeir G; Zwahlen, Marcel; Sailer, Irena

    2014-01-01

    The objective of this systematic review was to assess and compare the survival and complication rates of implant-supported prostheses reported in studies published in the year 2000 and before, to those reported in studies published after the year 2000. Three electronic searches complemented by manual searching were conducted to identify 139 prospective and retrospective studies on implant-supported prostheses. The included studies were divided in two groups: a group of 31 older studies published in the year 2000 or before, and a group of 108 newer studies published after the year 2000. Survival and complication rates were calculated using Poisson regression models, and multivariable robust Poisson regression was used to formally compare the outcomes of older and newer studies. The 5-year survival rate of implant-supported prostheses was significantly increased in newer studies compared with older studies. The overall survival rate increased from 93.5% to 97.1%. The survival rate for cemented prostheses increased from 95.2% to 97.9%; for screw-retained reconstruction, from 77.6% to 96.8%; for implant-supported single crowns, from 92.6% to 97.2%; and for implant-supported fixed dental prostheses (FDPs), from 93.5% to 96.4%. The incidence of esthetic complications decreased in more recent studies compared with older ones, but the incidence of biologic complications was similar. The results for technical complications were inconsistent. There was a significant reduction in abutment or screw loosening by implant-supported FDPs. On the other hand, the total number of technical complications and the incidence of fracture of the veneering material was significantly increased in the newer studies. To explain the increased rate of complications, minor complications are probably reported in more detail in the newer publications. The results of the present systematic review demonstrated a positive learning curve in implant dentistry, represented in higher survival rates and lower complication rates reported in more recent clinical studies. The incidence of esthetic, biologic, and technical complications, however, is still high. Hence, it is important to identify these complications and their etiology to make implant treatment even more predictable in the future.

  13. Full-arch milled titanium implant bridge: technical report.

    PubMed

    Peché, Wendy-Ann; Van Vuuren, Ludwig Jansen; Park, Chae

    2011-09-01

    The manufacturing of full-arch fixed implant-supported bridges with the use of the traditional lost wax technique remains a technical challenge. Distortion of the alloy during casting and subsequent heating cycles during porcelain build-up causes numerous problems. Fracturing of porcelain on large restorations is difficult and costly to restore. The fitting problems can be eliminated by utilising CAD/CAM technology in the manufacturing of long-span or full-arch titanium bridges. Repair of damaged porcelain can be simplified with the use of discrete, individually-removable crowns on the bridge.

  14. Single crowns in the resorbed posterior maxilla supported by either 6-mm implants or by 11-mm implants combined with sinus floor elevation surgery: a 1-year randomised controlled trial.

    PubMed

    Guljé, Felix L; Raghoebar, Gerry M; Vissink, Arjan; Meijer, Henny J A

    2014-01-01

    The aim of this randomised controlled trial was to assess the clinical performance of single crowns in the posterior maxilla supported by either 6-mm or 11-mm implants combined with maxillary sinus floor elevation. 41 consecutive patients with one missing premolar or molar in the posterior maxilla and with an estimated bone height of 6 to 8 mm in that area were included. Each patient was randomly allocated to one of the two treatment groups, namely to receive an 11-mm implant (Osseo Speed 4.0 S, Dentsply Implants, Mölndal, Sweden) in combination with maxillary sinus floor elevation surgery or to receive a 6-mm implant (Osseo Speed 4.0 S) without any grafting. After a 3-month osseointegration period, all implants were restored with custom-made titanium abutments and cemented zirconia-based porcelain crowns. Outcome measures were: implant survival; radiographic bone changes; plaque accumulation; bleeding tendency; peri-implant inflammation; presence of dental calculus; biological and technical complications; and patients' satisfaction. Clinical and radiographic examinations were performed at placement of the crown and 12 months thereafter. Patients' satisfaction was scored before treatment and after 12 months of functioning of the crown. One patient of the 11 mm implant group died during the follow-up. No implant failed and no biological or technical complications occurred. From loading to the 12 months follow-up, no difference was found in mean marginal bone changes between the groups (bone resorption in both groups 0.1 ± 0.3 mm). Clinical items revealed very healthy peri-implant soft tissues in both groups. Patients' satisfaction scores were high in both groups. 6-mm implants and 11-mm implants combined with sinus floor elevation surgery are equally successful to support a single crown in the resorbed posterior maxilla after 1-year follow-up.

  15. Totally implantable venous power ports of the forearm and the chest: initial clinical experience with port devices approved for high-pressure injections

    PubMed Central

    Goltz, J P; Noack, C; Petritsch, B; Kirchner, J; Hahn, D; Kickuth, R

    2012-01-01

    Objectives To evaluate the technical success, clinical outcome and safety of percutaneously placed totally implantable venous power ports (TIVPPs) approved for high-pressure injections, and to analyse their value for arterial phase CT scans. Methods Retrospectively, we identified 204 patients who underwent TIVPP implantation in the forearm (n=152) or chest (n=52) between November 2009 and May 2011. Implantation via an upper arm (forearm port, FP) or subclavian vein (chest port, CP) was performed under sonographic and fluoroscopic guidance. Complications were evaluated following the standards of the Society of Interventional Radiology. Power injections via TIVPPs were analysed, focusing on adequate functioning and catheter's tip location after injection. Feasibility of automatic bolus triggering, peak injection pressure and arterial phase aortic enhancement were evaluated and compared with 50 patients who had had power injections via classic peripheral cannulas. Results Technical success was 100%. Procedure-related complications were not observed. Catheter-related thrombosis was diagnosed in 15 of 152 FPs (9.9%, 0.02/100 catheter days) and in 1 of 52 CPs (1.9%, 0.002/100 catheter days) (p<0.05). Infectious complications were diagnosed in 9 of 152 FPs (5.9%, 0.014/100 catheter days) and in 2 of 52 CPs (3.8%, 0.003/100 catheter days) (p>0.05). Arterial bolus triggering succeeded in all attempts; the mean injection pressure was 213.8 psi. Aortic enhancement did not significantly differ between injections via cannulas and TIVPPs (p>0.05). Conclusions TIVPPs can be implanted with high technical success rates, and are associated with low rates of complications if implanted with sonographic and fluoroscopic guidance. Power injections via TIVPPs are safe and result in satisfying arterial contrast. Conventional ports should be replaced by TIVPPs. PMID:22674705

  16. [Technical feasibility of the implantation of a monorail stent system into the renal arteries without pre-dilatation].

    PubMed

    Neumann, C; Gschwendtner, M; Karnel, F; Mair, J; Dorffner, G; Dorffner, R

    2005-01-01

    To evaluate the technical feasibility of the implantation of the monorail RX Herculink system into the renal arteries without pre-dilatation. Forty-two patients (mean age 71 years) from four centers with a total of 44 renal artery stenoses underwent implantation of the RX Herculink stent. The mean grade of the stenosis was 83.8 %, the mean length 7.5 mm. The stenoses were ostial in 38 cases and in immediate proximity to the ostium in 6 cases. The mean follow-up-period was 57 weeks (24 - 176 weeks). In 42 cases, the implantation was successful without pre-dilatation. In 2 cases, pre-dilatation was carried out. In none of the cases, detachment of the stent from the balloon was observed. In one stenosis with a length of 17 mm, implantation of two stents was performed. In 9 cases, post-dilatation with a larger balloon or higher balloon pressure was necessary. Residual stenoses exceeding 30 % were not observed. Two patients developed local bleeding at the puncture site. During the follow-up, restenoses were observed in 5 stents after 26 to 126 weeks, which necessitated a second intervention in 3 cases (PTA in 2 cases, re-stenting in 1 case). The primary patency rate after 6 and 12 months was 0.92 +/- 0.056 according to Kaplan-Meier, the secondary patency rate after 6 and 12 months was 1.0 +/- 0.0. Implantation of the RX Herculink stent system into the renal arteries without pre-dilatation is technically feasible and safe. Even without pre-dilatation, the stent-system can be advanced through the stenosis without detachment. The complication rate is low. Our clinical results are comparable to previous studies.

  17. Technical aids for the flexible use of the Leksell stereotactic system.

    PubMed

    Salcman, M; Bellis, E H; Sewchand, W; Amin, P

    1989-06-01

    As part of a multimodality therapy program for intracranial tumours, 105 stereotactic and implant procedures have been carried out utilizing the CT-compatible Leksell stereotactic system. In the iridium implant series, 86 catheters have been implanted for an average of 3.6 targets per patient. There have been no deaths or missed targets and only two incidential haemorrhages detected. In order to facilitate the reliability, safety and speed of multiple catheter insertion, several techniques have been developed including: (a) a standardized single-length catheter and flange system; (b) a ceramic catheter for microwave hyperthermia; (c) a mnemonic card for ease of calculation; (d) a radiation shield for nursing; (e) a stereotactic drill and surgical approaches to far lateral and posterior fossa targets. Principles for the use of these technical aids are discussed.

  18. More than a device: today's medical technology companies provide value through service.

    PubMed

    McCoy, Fred

    2003-01-01

    When physicians implant cardiac rhythm management devices, they establish a long-term relationship with those devices and with the manufacturers of those devices. The therapeutic value that each device will provide to its patient is enhanced throughout the life of the device by the services that the manufacturer provides. Services are provided prior to, during and long after implantation. Services include physician and allied health professional training, quality assurance programs, therapy outreach initiatives, on site technical support during device implantation and follow-up, technical service expertise and customer service support. The costs of these services are substantial. When assessed on a per device basis, the service costs may actually exceed the costs of manufacture. Further, the costs of these services are rising. Over the past five years, the number of implanted cardiac rhythm management devices has doubled. Industry field forces have tripled in size. Clearly, industry is dedicated to providing service as a critical element in achieving excellent patient outcomes.

  19. A subperiosteal maxillary implant causing severe osteolysis.

    PubMed

    Maï, Nguyen Tan; Jean-Baptiste, Caruhel; Hossein, Khonsari Roman

    2018-06-22

    Subperiosteal implant denture therapy was initially introduced in 1942 in Sweden and was then used worldwide for the treatment of fully edentulous maxillary or mandibular arches with advanced bone atrophy. Most authors describe decent success rates for mandibular subperiosteal implants in cases with major bone atrophy but follow-up studies for maxillary subperiosteal implants are not available. Here, we report a case of severe maxillary osteolysis secondary to the placement of a subperiosteal in-house implant. Subperiosteal implants are rarely used today but patients still carrying these devices with severe complications can be challenging to manage. New technical advances, including the use of surgical planification and additive manufacturing, may lead to a new interest in subperiosteal implants. Copyright © 2018. Published by Elsevier Masson SAS.

  20. Endoscopy/EUS-guided fiducial marker placement in patients with esophageal cancer: a comparative analysis of 3 types of markers.

    PubMed

    Machiels, Melanie; van Hooft, Jeanin; Jin, Peng; van Berge Henegouwen, Mark I; van Laarhoven, Hanneke M; Alderliesten, Tanja; Hulshof, Maarten C

    2015-10-01

    Markers placed at the borders of esophageal tumors are potentially useful to facilitate radiotherapy (RT) target delineation, which offers the possibility of image-guided RT. To evaluate and compare the feasibility and technical benefit of endoscopy/EUS-guided marker placement of 3 different types of markers in patients with esophageal cancer referred for RT. Prospective, single-center, feasibility and comparative study. Tertiary-care medical center. Thirty patients with esophageal cancer who were referred for RT. Patients underwent endoscopy/EUS-guided implantation of 1 type of marker. A solid gold marker (SM) with fixed dimensions, a flexible coil-shaped gold marker (FM) with hand-cut length (2-10 mm), and a radiopaque hydrogel marker (HG) were used. Technical feasibility and adverse events were registered. CT scans and cone-beam CT scans (CBCT) acquired during RT were analyzed to determine and compare the visibility and continuous clear visibility of the implanted markers. Technical feasibility, technical benefit, and adverse events of 3 types of markers. A total of 101 markers were placed in 30 patients. Implantation was technically feasible in all patients without grade 3 to 4 adverse events. Two patients with asymptomatic mediastinitis and one with asymptomatic pneumothorax were seen. Visibility on CT scan of all 3 types of implanted markers was adequate for target delineation. Eighty percent of FMs remained continuously visible over the treatment period on CBCT, significantly better than SMs (63%) and HGs (11%) (P = .015). When we selected FMs ≥5 mm, 90.5% remained visible on CBCT between implantation and the end of RT. Single-center, nonrandomized design. Endoscopy/EUS-guided fiducial marker placement for esophageal cancer is both safe and feasible and can be used for target volume delineation purposes on CT. Our results imply a significant advantage of FMs over SMs and HGs, regarding visibility and continuous clear visibility over the treatment period. ( NTR4724.). Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  1. Vehicle infrastructure integration proof of concept : technical description--vehicle : final report

    DOT National Transportation Integrated Search

    2009-05-19

    This report provides the technical description of the VII system developed for the Cooperative Agreement VII Program between the USDOT and the VII Consortium. The basic architectural elements are summarized and detailed descriptions of the hardware a...

  2. Transplantation of Bioprinted Tissues and Organs: Technical and Clinical Challenges and Future Perspectives.

    PubMed

    Ravnic, Dino J; Leberfinger, Ashley N; Koduru, Srinivas V; Hospodiuk, Monika; Moncal, Kazim K; Datta, Pallab; Dey, Madhuri; Rizk, Elias; Ozbolat, Ibrahim T

    2017-07-01

    : Three-dimensional (3D) bioprinting is a revolutionary technology in building living tissues and organs with precise anatomic control and cellular composition. Despite the great progress in bioprinting research, there has yet to be any clinical translation due to current limitations in building human-scale constructs, which are vascularized and readily implantable. In this article, we review the current limitations and challenges in 3D bioprinting, including in situ techniques, which are one of several clinical translational models to facilitate the application of this technology from bench to bedside. A detailed discussion is made on the technical barriers in the fabrication of scalable constructs that are vascularized, autologous, functional, implantable, cost-effective, and ethically feasible. Clinical considerations for implantable bioprinted tissues are further expounded toward the correction of end-stage organ dysfunction and composite tissue deficits.

  3. A Critical Review of Dental Implant Materials with an Emphasis on Titanium versus Zirconia

    PubMed Central

    Osman, Reham B.; Swain, Michael V.

    2015-01-01

    The goal of the current publication is to provide a comprehensive literature review on the topic of dental implant materials. The following paper focuses on conventional titanium implants and more recently introduced and increasingly popular zirconia implants. Major subtopics include the material science and the clinical considerations involving both implant materials and the influence of their physical properties on the treatment outcome. Titanium remains the gold standard for the fabrication of oral implants, even though sensitivity does occur, though its clinical relevance is not yet clear. Zirconia implants may prove to be promising in the future; however, further in vitro and well-designed in vivo clinical studies are needed before such a recommendation can be made. Special considerations and technical experience are needed when dealing with zirconia implants to minimize the incidence of mechanical failure. PMID:28787980

  4. EEG Radiotelemetry in Small Laboratory Rodents: A Powerful State-of-the Art Approach in Neuropsychiatric, Neurodegenerative, and Epilepsy Research

    PubMed Central

    Lundt, Andreas; Wormuth, Carola; Siwek, Magdalena Elisabeth; Müller, Ralf; Henseler, Christina; Broich, Karl; Papazoglou, Anna; Weiergräber, Marco

    2016-01-01

    EEG radiotelemetry plays an important role in the neurological characterization of transgenic mouse models of neuropsychiatric and neurodegenerative diseases as well as epilepsies providing valuable insights into underlying pathophysiological mechanisms and thereby facilitating the development of new translational approaches. We elaborate on the major advantages of nonrestraining EEG radiotelemetry in contrast to restraining procedures such as tethered systems or jacket systems containing recorders. Whereas a main disadvantage of the latter is their unphysiological, restraining character, telemetric EEG recording overcomes these disadvantages. It allows precise and highly sensitive measurement under various physiological and pathophysiological conditions. Here we present a detailed description of a straightforward successful, quick, and efficient technique for intraperitoneal as well as subcutaneous pouch implantation of a standard radiofrequency transmitter in mice and rats. We further present computerized 3D-stereotaxic placement of both epidural and deep intracerebral electrodes. Preoperative preparation of mice and rats, suitable anaesthesia, and postoperative treatment and pain management are described in detail. A special focus is on fields of application, technical and experimental pitfalls, and technical connections of commercially available radiotelemetry systems with other electrophysiological setups. PMID:26819775

  5. Immediate implant-supported oral rehabilitation using a photocurable plastic skull model and laser welding. A technical note on the screw-retained type: Part 1.

    PubMed

    Tomotake, Yoritoki; Ishida, Osamu; Kanitani, Hideo; Ichikawa, Tetsuo

    2002-01-01

    This article describes a new procedure for immediate implant-supported oral rehabilitation using a photocurable resin skull model and a laser-welding apparatus. Preoperatively, the framework was fabricated on a photocurable resin skull model produced from a CT scan and individually designed guide template. The implants were immediately placed using the guide template; laser welding connected the components of framework. Despite the custom-made prosthesis, the total treatment from implant placement to superstructure placement can be completed within only 1 day. This procedure for immediate implant-supported oral rehabilitation using a photocurable resin skull model and a laser-welding apparatus may be useful for any implant system and patient.

  6. Technical success from endovascular aneurysm repair in the post-marketing era: a multicenter prospective trial.

    PubMed

    Naslund, Thomas C; Becker, Stacey Y

    2003-01-01

    Evaluation of post-marketing success with the Ancure Endovascular Graft (AEG) was accomplished by review of a multicenter, prospective trial involving 46 centers and 163 patients. A second cohort of patients (n = 350) treated with the AEG under a controlled-use interval prior to the prospective trial was simultaneously evaluated. Technical success in both groups of patients (96.9% and 97.4%, respectively) was similar to what was reported in pre-market clinical trials. Operative implantation complications unique to the AEG included graft limb stenosis/occlusion in 35.6 and 31.4%, contralateral pull wire being caught on hooks in 33.7 and 28%, failure to seal (type I endoleak) in 17.2 and 18.3%, jacket guard being stuck in 12.9 and 11%, contralateral wire being stuck in 6.8 and 7.1%, high jacket retraction force in 16 and 8.5%, and inability to retract jacket in 1.8 and 0.5% of patients involved in the multicenter trial and controlled-use interval, respectively. One of four patients undergoing conversion in the prospective trial had graft misdeployment as a mode of failure. Three were converted for access failure. The 30-day mortality rate in the prospective trial was 3.7%. Interventions to resolve implantation-related events included stenting, guide catheter manipulations, wire exchanges, and delivery catheter disassembly. These interventions were successful in virtually every case. Open surgical procedures were not needed to correct these operative problems. Results from this study demonstrate excellent technical success with the AEG in the post-market era. Interventions to resolve implantation complications, when utilized, are highly successful in facilitating AEG implantation and providing technical success.

  7. Analysis and evalaution in the production process and equipment area of the low-cost solar array project. [including modifying gaseous diffusion and using ion implantation

    NASA Technical Reports Server (NTRS)

    Goldman, H.; Wolf, M.

    1979-01-01

    The manufacturing methods for photovoltaic solar energy utilization are assessed. Economic and technical data on the current front junction formation processes of gaseous diffusion and ion implantation are presented. Future proposals, including modifying gaseous diffusion and using ion implantation, to decrease the cost of junction formation are studied. Technology developments in current processes and an economic evaluation of the processes are included.

  8. Acrylic resin guide for locating the abutment screw access channel of cement-retained implant prostheses.

    PubMed

    Ahmed, Ayman; Maroulakos, Georgios; Garaicoa, Jorge

    2016-05-01

    Abutment screw loosening represents a common and challenging technical complication of cement-retained implant prostheses. This article describes the fabrication of a simple and accurate poly(methyl methacrylate) guide for identifying the location and angulation of the abutment screw access channel of a cement-retained implant prosthesis with a loosened abutment screw. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  9. Bringing Hearing to the Deaf--Cochlear Implants: a Technical and Personal Account

    NASA Astrophysics Data System (ADS)

    Shipsey, Ian

    2006-04-01

    Cochlear implants are the first device to successfully restore neural function. They have instigated a popular but controversial revolution in the treatment of deafness, and they serve as a model for research in neuroscience and biomedical engineering. In this talk the physiology of natural hearing will be reviewed from the perspective of a physicist, and the function of cochlear implants will be described in the context of historical treatments, electrical engineering, psychophysics, clinical evaluation of efficacy and personal experience. The social implications of cochlear implantation and the future outlook for auditory prostheses will also be discussed.

  10. Gun Control for VBE-E: User Guide and Technical Description

    DTIC Science & Technology

    2006-11-01

    Defence R& D Canada – Atlantic DEFENCE DÉFENSE & Gun Control for VBE-E User Guide and Technical Description Tania E. Wentzell Technical Memorandum...Defence R& D Canada – Atlantic Technical Memorandum DRDC Atlantic TM 2006-245 November 2006 DRDC Atlantic TM 2006-245...component of the distributed experimentation environment used by the Virtual Combat System (VCS) Group at Defence R& D Canada – Atlantic (DRDC Atlantic

  11. Standardization of reliability reporting for cochlear implants: an interim report.

    PubMed

    Backous, Douglas D; Watson, Stacey D

    2007-04-01

    To propose a standard definition of "out of specification" for cochlear implants and a paradigm for inclusion of category C of the ISO standard 5841-2:2000 for reporting in cumulative survival statistics. A standard definition of "out of specification" and consistent reporting by manufacturers of cochlear implants will create a fair and consistent representation of cumulative survival. This will allow discernment of differences between manufacturers for reliability and for detection of trends in reliability between model types from the same manufacturer. Three separate meetings with representatives of the three manufacturers of cochlear implants marketed in the United States were staged over a 13-mo period. Standard questions, created by the authors, were addressed by each representative to determine the current state of device reliability reporting. Results were presented to clinicians at the William House Cochlear Implant study Group and the Implantable devices sub-committee of the American Academy of Otolaryngology (2004, 2005) and at the 8th International Cochlear Implant Conference (2004) for feedback. After assimilation of feedback by all parties, the standard was written and reviewed by representatives from each manufacturer for accuracy of data. A complaint-driven standard was developed. A "cochlear implant" as an internal device placed and skin closed in surgery. An internal device is "out of specification" when one or more technical characteristics is outside the limits of normal function and results in explantation or non-use by the patient." Children will be reported separately from adults, each model of device will be reported on annually, a minimum of 200 devices must be in each model group for Cumulative Survival Reporting (CSR). Confidence limits are set at 95%. Explants will be determined to be "biological" or "technical." Technical explants are included in CSR reports. Devices failing to meet specifications set by the manufacturer, not in use but still in situ due to patient choice not to be re-implanted are considered category C and included in CSR reports. Implants that cannot be classified at explant are placed in an "under investigation" category while evaluation is completed. If no classification is made by 6 months, these devices will be included in the CSR report. Notification to the implant center regarding "in" or "out of specification" will be made within 60 d of the explant arriving at the manufacturer with final root cause of failure reported to centers when complete. Information will be passed on to patients by members of the implant team. A standardized form will be created to provide the manufacturers with necessary patient information to guide reliability analysis, including performance after re-implant. The standard for reliability reporting described in this paper improves patient care by presenting data which are understandable to clinicians delivering cochlear implant services. It fosters fair and accurate reporting without discriminating or granting perceived advantage to any manufacturer. This standard provides a basis for reporting research related to or including device reliability in the medical literature.

  12. Technical aspects of neurostimulation: Focus on equipment, electric field modeling, and stimulation protocols.

    PubMed

    Klooster, D C W; de Louw, A J A; Aldenkamp, A P; Besseling, R M H; Mestrom, R M C; Carrette, S; Zinger, S; Bergmans, J W M; Mess, W H; Vonck, K; Carrette, E; Breuer, L E M; Bernas, A; Tijhuis, A G; Boon, P

    2016-06-01

    Neuromodulation is a field of science, medicine, and bioengineering that encompasses implantable and non-implantable technologies for the purpose of improving quality of life and functioning of humans. Brain neuromodulation involves different neurostimulation techniques: transcranial magnetic stimulation (TMS), transcranial direct current stimulation (tDCS), vagus nerve stimulation (VNS), and deep brain stimulation (DBS), which are being used both to study their effects on cognitive brain functions and to treat neuropsychiatric disorders. The mechanisms of action of neurostimulation remain incompletely understood. Insight into the technical basis of neurostimulation might be a first step towards a more profound understanding of these mechanisms, which might lead to improved clinical outcome and therapeutic potential. This review provides an overview of the technical basis of neurostimulation focusing on the equipment, the present understanding of induced electric fields, and the stimulation protocols. The review is written from a technical perspective aimed at supporting the use of neurostimulation in clinical practice. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Hearing is Believing

    NASA Technical Reports Server (NTRS)

    2003-01-01

    This paper presents a discussion on the cochlear implant. This device was developed by Adam Kissiah, who suffers from hearing loss. Driven by his own hearing problem and three failed corrective surgeries, Kissiah started working in the mid-1970s on this surgically implantable device that provides hearing sensation to persons with severe-to-profound hearing loss who receive little or no benefit from hearing aids. Uniquely, the cochlear implant concept was not based on theories of medicine, as Kissiah had no medical background whatsoever. Instead, he utilized the technical expertise he learned while working as an electronics instrumentation engineer at NASA s Kennedy Space Center for the basis of his invention. This took place over 3 years, when Kissiah would spend his lunch breaks and evenings in Kennedy s technical library, studying the impact of engineering principles on the inner ear. In April of 2003, Kissiah was inducted into the Space Foundation's U.S. Space Technology Hall of Fame for his invention

  14. Locked nailing for the treatment of displaced articular fractures of the calcaneus: description of a new procedure with calcanail(®).

    PubMed

    Goldzak, Mario; Mittlmeier, Thomas; Simon, Patrick

    2012-05-01

    Although open reduction and internal fixation is considered the best method for treating displaced articular fractures of the calcaneus, lateral approach is at high risk for wound healing complications. For this reason, the authors developed a posterior approach and a new implant to perform both intrafocal reduction and internal fixation. The aim of this technical note is to describe this method of treatment for displaced articular fractures of the calcaneus, which offered the following advantages: (a) the creation of a working channel that provides also a significant bone autograft, (b) the intrafocal reduction of the displaced articular surface, (c) the insertion of a locking nail that maintains the reduced articular surface at the right height, (d) the possibility to switch from an ORIF to a reconstruction arthrodesis with the same approach and instrumentation in case of severely damaged posterior facet.

  15. Fringe-shifting single-projector moiré topography application for cotyle implantate abrasion measurement

    NASA Astrophysics Data System (ADS)

    Rössler, Tomáš; Hrabovský, Miroslav; Pluháček, František

    2005-08-01

    The cotyle implantate is abraded in the body of patient and its shape changes. Information about the magnitude of abrasion is contained in the result contour map of the implantate. The locations and dimensions of abraded areas can be computed from the contours deformation. The method called the single-projector moire topography was used for the contour lines determination. The theoretical description of method is given at first. The design of the experimental set-up follows. The light grating projector was developed to realize the periodic structure on the measured surface. The method of fringe-shifting was carried out to increase the data quantity. The description of digital processing applied to the moire grating images is introduced at the end together with the examples of processed images.

  16. Complication incidence of two implant systems up to six years: a comparison between internal and external connection implants.

    PubMed

    Chae, Sung-Wook; Kim, Young-Sung; Lee, Yong-Moo; Kim, Won-Kyung; Lee, Young-Kyoo; Kim, Su-Hwan

    2015-02-01

    This study was conducted to compare the cumulative survival rates (CSRs) and the incidence of postloading complications (PLCs) between a bone-level internal connection system (ICS-BL) and an external connection system (ECS). The medical records of patients treated with either a ICS-BL or ECS between 2007 and 2010 at Asan Medical Center were reviewed. PLCs were divided into two categories: biological and technical. Biological complications included >4 mm of probing pocket depth, thread exposure in radiographs, and soft tissue complications, whereas technical complications included chipping of the veneering material, fracture of the implant, fracture of the crown, loosening or fracture of the abutment or screw, loss of retention, and loss of access hole filling material. CSRs were determined by a life-table analysis and compared using the log-rank chi-square test. The incidence of PLC was compared with the Pearson chi-squared test. A total of 2,651 implants in 1,074 patients (1,167 ICS-BLs in 551 patients and 1,484 ECSs in 523 patients) were analyzed. The average observation periods were 3.4 years for the ICS-BLs and 3.1 years for the ECSs. The six-year CSR of all implants was 96.1% (94.9% for the ICS-BLs and 97.1% for the ECSs, P=0.619). Soft tissue complications were more frequent with the ECSs (P=0.005) and loosening or fracture of the abutment or screw occurred more frequently with the ICS-BLs (P<0.001). Within the limitations of this study, the ICS-BL was more prone to technical complications while the ECS was more vulnerable to biological complications.

  17. A method and technical equipment for an acute human trial to evaluate retinal implant technology

    NASA Astrophysics Data System (ADS)

    Hornig, Ralf; Laube, Thomas; Walter, Peter; Velikay-Parel, Michaela; Bornfeld, Norbert; Feucht, Matthias; Akguel, Harun; Rössler, Gernot; Alteheld, Nils; Lütke Notarp, Dietmar; Wyatt, John; Richard, Gisbert

    2005-03-01

    This paper reports on methods and technical equipment to investigate the epiretinal stimulation of the retina in blind human subjects in acute trials. Current is applied to the retina through a thin, flexible microcontact film (microelectrode array) with electrode diameters ranging from 50 to 360 µm. The film is mounted in a custom-designed surgical tool that is hand-held by the surgeon during stimulation. The eventual goal of the work is the development of a chronically implantable retinal prosthesis to restore a useful level of vision to patients who are blind with outer retinal degenerations, specifically retinitis pigmentosa and macular degeneration.

  18. Implantable Sensors for Regenerative Medicine

    PubMed Central

    Klosterhoff, Brett S.; Tsang, Melissa; She, Didi; Ong, Keat Ghee; Allen, Mark G.; Willett, Nick J.; Guldberg, Robert E.

    2017-01-01

    The translation of many tissue engineering/regenerative medicine (TE/RM) therapies that demonstrate promise in vitro are delayed or abandoned due to reduced and inconsistent efficacy when implemented in more complex and clinically relevant preclinical in vivo models. Determining mechanistic reasons for impaired treatment efficacy is challenging after a regenerative therapy is implanted due to technical limitations in longitudinally measuring the progression of key environmental cues in vivo. The ability to acquire real-time measurements of environmental parameters of interest including strain, pressure, pH, temperature, oxygen tension, and specific biomarkers within the regenerative niche in situ would significantly enhance the information available to tissue engineers to monitor and evaluate mechanisms of functional healing or lack thereof. Continued advancements in material and fabrication technologies utilized by microelectromechanical systems (MEMSs) and the unique physical characteristics of passive magnetoelastic sensor platforms have created an opportunity to implant small, flexible, low-power sensors into preclinical in vivo models, and quantitatively measure environmental cues throughout healing. In this perspective article, we discuss the need for longitudinal measurements in TE/RM research, technical progress in MEMS and magnetoelastic approaches to implantable sensors, the potential application of implantable sensors to benefit preclinical TE/RM research, and the future directions of collaborative efforts at the intersection of these two important fields. PMID:27987300

  19. Characterization of silicon-gate CMOS/SOS integrated circuits processed with ion implantation

    NASA Technical Reports Server (NTRS)

    Woo, D. S.

    1977-01-01

    Progress in developing the application of ion implantation techniques to silicon gate CMOS/SOS processing is described. All of the conventional doping techniques such as in situ doping of the epi-film and diffusion by means of doped oxides are replaced by ion implantation. Various devices and process parameters are characterized to generate an optimum process by the use of an existing SOS test array. As a result, excellent circuit performance is achieved. A general description of the all ion implantation process is presented.

  20. Technical devices for hearing-impaired individuals: cochlear implants and brain stem implants - developments of the last decade

    PubMed Central

    Müller, Joachim

    2005-01-01

    Over the past two decades, the fascinating possibilities of cochlear implants for congenitally deaf or deafened children and adults developed tremendously and created a rapidly developing interdisciplinary research field. The main advancements of cochlear implantation in the past decade are marked by significant improvement of hearing and speech understanding in CI users. These improvements are attributed to the enhancement of speech coding strategies. The Implantation of more (and increasingly younger) children as well as the possibilities of the restoration of binaural hearing abilities with cochlear implants reflect the high standards reached by this development. Despite this progress, modern cochlear implants do not yet enable normal speech understanding, not even for the best patients. In particular speech understanding in noise remains problematic [1]. Until the mid 1990ies research concentrated on unilateral implantation. Remarkable and effective improvements have been made with bilateral implantation since 1996. Nowadays an increasing numbers of patients enjoy these benefits. PMID:22073052

  1. Technical devices for hearing-impaired individuals: cochlear implants and brain stem implants - developments of the last decade.

    PubMed

    Müller, Joachim

    2005-01-01

    Over the past two decades, the fascinating possibilities of cochlear implants for congenitally deaf or deafened children and adults developed tremendously and created a rapidly developing interdisciplinary research field.The main advancements of cochlear implantation in the past decade are marked by significant improvement of hearing and speech understanding in CI users. These improvements are attributed to the enhancement of speech coding strategies.The Implantation of more (and increasingly younger) children as well as the possibilities of the restoration of binaural hearing abilities with cochlear implants reflect the high standards reached by this development. Despite this progress, modern cochlear implants do not yet enable normal speech understanding, not even for the best patients. In particular speech understanding in noise remains problematic [1]. Until the mid 1990ies research concentrated on unilateral implantation. Remarkable and effective improvements have been made with bilateral implantation since 1996. Nowadays an increasing numbers of patients enjoy these benefits.

  2. Technical aspects of the integration of three-dimensional treatment planning dose parameters (GEC-ESTRO Working Group) into pre-implant planning for LDR gynecological interstitial brachytherapy.

    PubMed

    Chi, A; Gao, M; Nguyen, N P; Albuquerque, K

    2009-06-01

    This study investigates the technical feasibility of pre-implant image-based treatment planning for LDR GYN interstitial brachytherapy(IB) based on the GEC-ESTRO guidelines. Initially, a virtual plan is generated based on the prescription dose and GEC-ESTRO defined OAR dose constraints with a pre-implant CT. After the actual implant, a regular diagnostic CT was obtained and fused with our pre-implant scan/initial treatment plan in our planning software. The Flexi-needle position changes, and treatment plan modifications were made if needed. Dose values were normalized to equivalent doses in 2 Gy fractions (LQED 2 Gy) derived from the linear-quadratic model with alpha/beta of 3 for late responding tissues and alpha/beta of 10 for early responding tissues. D(90) to the CTV, which was gross tumor (GTV) at the time of brachytherapy with a margin to count for microscopic disease, was 84.7 +/- 4.9% of the prescribed dose. The OAR doses were evaluated by D(2cc) (EBRT+IB). Mean D(2cc) values (LQED(2Gy)) for the rectum, bladder, sigmoid, and small bowel were the following: 63.7 +/- 8.4 Gy, 61.2 +/- 6.9 Gy, 48.0 +/- 3.5 Gy, and 49.9 +/- 4.2 Gy. This study confirms the feasibility of applying the GEC-ESTRO recommended dose parameters in pre-implant CT-based treatment planning in GYN IB. In the process, this pre-implant technique also demonstrates a good approximation of the target volume dose coverage, and doses to the OARs.

  3. Endoscopic management of complications of self-expandable metal stents for treatment of malignant esophageal stenosis and tracheoesophageal fistulas.

    PubMed

    Bor, Renáta; Fábián, Anna; Bálint, Anita; Farkas, Klaudia; Szűcs, Mónika; Milassin, Ágnes; Czakó, László; Rutka, Mariann; Molnár, Tamás; Szepes, Zoltán

    2017-08-01

    Self-expandable metal stent (SEMS) implantation may rapidly improve the symptoms of malignant esophageal stenosis and tracheoesophageal fistulas (TEF). However, dysphagia often returns subsequently and repeated endoscopic intervention may be necessary. The aims of the study were to identify the risk factors of complications, and the frequency and efficacy of repeated endoscopic interventions; and to provide technical recommendations on appropriate stent selection. We analyzed retrospectively the clinical data of 212 patients with locally advanced esophageal cancer who underwent SEMS implantation. A total of 238 SEMS implantations were performed with 99.06% technical success and 1.26% procedure-related deaths in the enrolled 212 cases. Complications occurred in 84 patients (39.62%) and in 55 cases (25.94%) repeated endoscopic procedures were required. Early reintervention 24-48 h after the stent implantations was necessary due to stent migration (12 cases), arrhythmia (2 cases), intolerable retrosternal pain (1 case) and dyspnea (1 case). An average of 1.98 repeated gastroscopies (range 1-6; median 2), 13.58 weeks (range 1.5-48; median 11) after the stent implantation were performed during the follow-up period: 37 stent repositions, 23 restent implantations, 15 endoscopic esophageal dilations and 7 stent removals. In 48 cases (87.3%) oral feeding of patients was made possible by endoscopic interventions. In a quarter of SEMS implantations, complications occur that can be successfully managed by endoscopic interventions. Our experiences have shown that individualized stent choice may substantially reduce the complications rate and make repeated endoscopic interventions easier.

  4. Music Perception of Cochlear Implant Recipients with Implications for Music Instruction: A Review of the Literature

    ERIC Educational Resources Information Center

    Hsiao, Feilin; Gfeller, Kate

    2012-01-01

    This review of the literature presents a systematic analysis of the capabilities and limitations of cochlear implant (CI) recipients with regard to music perception. Specifically, it (a) analyzes individual components of music (e.g., rhythm, timbre, and pitch) as they interface with the technical characteristics of CIs and the perceptual abilities…

  5. Exotic encounters with dental implants: managing complications with unidentified systems.

    PubMed

    Mattheos, N; Janda, M Schittek

    2012-06-01

    As the application of dental implants increases worldwide, so is the number of technical and biological complications that general dental practitioners will be called to manage, while maintaining implant patients. In addition, the greater patient mobility encountered today combined with a growing trend of 'dental implant tourism' will very often result in situations where the dentist is requested to deal with complications in implants placed elsewhere and which sometimes might be of an 'exotic' system one cannot directly recognize. Such a situation can pose significant challenges to even experienced clinicians. The challenges are not only in the scientific field, but often include professional and ethical implications. This case report will discuss strategies for the management of implant complications in cases of unidentified implant systems. Critical factors in such situations would be the clinician's experience and special training, the correct radiographic technique, as well as access to the appropriate tools and devices. © 2012 Australian Dental Association.

  6. Implantable radio frequency identification sensors: wireless power and communication.

    PubMed

    Hutchens, Chriswell; Rennaker, Robert L; Venkataraman, Srinivasan; Ahmed, Rehan; Liao, Ran; Ibrahim, Tamer

    2011-01-01

    There are significant technical challenges in the development of a fully implantable wirelessly powered neural interface. Challenges include wireless transmission of sufficient power to the implanted device to ensure reliable operation for decades without replacement, minimizing tissue heating, and adequate reliable communications bandwidth. Overcoming these challenges is essential for the development of implantable closed loop system for the treatment of disorders ranging from epilepsy, incontinence, stroke and spinal cord injury. We discuss the development of the wireless power, communication and control for a Radio-Frequency Identification Sensor (RFIDS) system with targeted power range for a 700 mV, 30 to 40 uA load attained at -2 dBm.

  7. Dual jaw treatment of edentulism using implant-supported monolithic zirconia fixed prostheses.

    PubMed

    Altarawneh, Sandra; Limmer, Bryan; Reside, Glenn J; Cooper, Lyndon

    2015-01-01

    This case report describes restoration of the edentulous maxilla and mandible with implant supported fixed prostheses using monolithic zirconia, where the incisal edges and occluding surfaces were made of monolithic zirconia. Edentulism is a debilitating condition that can be treated with either a removable or fixed dental prosthesis. The most common type of implant-supported fixed prosthesis is the metal acrylic (hybrid), with ceramo-metal prostheses being used less commonly in complete edentulism. However, both of these prostheses designs are associated with reported complications of screw loosening or fracture and chipping of acrylic resin and porcelain. Monolithic zirconia implant-supported fixed prostheses have the potential for reduction of such complications. In this case, the CAD/CAM concept was utilized in fabrication of maxillary and mandibular screw-retained implant-supported fixed prostheses using monolithic zirconia. Proper treatment planning and execution coupled with utilizing advanced technologies contributes to highly esthetic results. However, long-term studies are required to guarantee a satisfactory long-term outcome of this modality of treatment. This case report describes the clinical and technical procedures involved in fabrication of maxillary and mandibular implant-supported fixed prostheses using monolithic zirconia as a treatment of edentulism, and proposes the possible advantages associated with using monolithic zirconia in eliminating dissimilar interfaces in such prostheses that are accountable for the most commonly occurring technical complication for these prostheses being chipping and fracture of the veneering material. © 2015 Wiley Periodicals, Inc.

  8. Method of identification of patent trends based on descriptions of technical functions

    NASA Astrophysics Data System (ADS)

    Korobkin, D. M.; Fomenkov, S. A.; Golovanchikov, A. B.

    2018-05-01

    The use of the global patent space to determine the scientific and technological priorities for the technical systems development (identifying patent trends) allows one to forecast the direction of the technical systems development and, accordingly, select patents of priority technical subjects as a source for updating the technical functions database and physical effects database. The authors propose an original method that uses as trend terms not individual unigrams or n-gram (usually for existing methods and systems), but structured descriptions of technical functions in the form “Subject-Action-Object” (SAO), which in the authors’ opinion are the basis of the invention.

  9. Technical tips during implantation of selective upper airway stimulation.

    PubMed

    Heiser, Clemens; Thaler, Erica; Soose, Ryan J; Woodson, B Tucker; Boon, Maurits

    2018-03-01

    Selective upper airway stimulation is now well-established in the United States and in several European countries, with more than 1,000 patients implanted since U.S. Food and Drug Administration approval in April 2014. The authors herein, all head and neck surgeons, account for approximately one of every five implants completed to date. Several of the authors also provide comprehensive longitudinal care of their patients as dual-specialty sleep medicine physicians. Multi-center, retrospective clinical analysis. More than 300 implants have been evaluated and reviewed in five different implant centers (Germany, United States). This analysis shares tips and techniques from the collective experiences with more than 300 implants, which can help newer implanters learn vicariously both for standard practices in executing routine implants through activation and, importantly, for working through more challenging encounters with anatomy, special patient phenotypes, system testing, and troubleshooting. These tips should help new implanters handle most of the situations arising during implantation and avoid common pitfalls. Laryngoscope, 128:756-762, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  10. Portal Vein Stenting Combined with Iodine-125 Seeds Endovascular Implantation Followed by Transcatheter Arterial Chemoembolization for Treatment of Hepatocellular Carcinoma Patients with Portal Vein Tumor Thrombus

    PubMed Central

    Zhou, Tanyang; Zhu, Tongyin; Zhang, Yuelin; Nie, Chunhui; Ai, Jing; Zhou, Guanhui; Zhang, Aibin; Dong, Meng-Jie; Wang, Wei-Lin

    2016-01-01

    Aim was to assess the therapeutic value of portal vein stenting (PVS) combined with iodine-125 seed (125I seed) strand endovascular implantation followed by transcatheter arterial chemoembolization (TACE) for treating patients with hepatocellular carcinoma (HCC) and portal vein tumor thrombus (PVTT). This was a retrospective study of 34 patients aged 29–81 years, diagnosed HCC with PVTT, and treated with PVS combined with 125I seed strand endovascular implantation followed by TACE between January 2012 and August 2014. Survival, stent patency, technical success rate, complications related to the procedure, and adverse events were recorded. The technical success rate was 100%. No serious procedure-related adverse event was recorded. The median survival was 147 days. The cumulative survival rates and stent patency rates at 90, 180, and 360 days were 94.1%, 61.8%, and 32.4% and 97.1% (33/34), 76.9% (24/34), and 29.4% (10/34), respectively. PVS combined with 125I seed strand endovascular implantation followed by TACE is feasible for patients with HCC and PVTT. It resulted in appropriate survival and stent patency, with no procedure-related adverse effects. PMID:27999793

  11. Computer-assisted design/computer-assisted manufacturing zirconia implant fixed complete prostheses: clinical results and technical complications up to 4 years of function.

    PubMed

    Papaspyridakos, Panos; Lal, Kunal

    2013-06-01

    To report the clinical results and technical complications with computer-assisted design/computer-assisted manufacturing (CAD/CAM) zirconia, implant fixed complete dental prostheses (IFCDPs) after 2-4 years in function. Fourteen consecutive edentulous patients (16 edentulous arches) were included in this study. Ten of the patients were women and four were men, with an average age of 58 years (range: 35-71). Ten mandibular and six maxillary arches were restored with porcelain fused to zirconia (PFZ) IFCDPs. Of the 16 arches, 14 received one-piece and 2 received segmented two-piece IFCDPs, respectively. The mean clinical follow-up period was 3 years (range: 2-4). At the last recall appointment, biological and technical parameters of dental implant treatment were evaluated. The implant and prosthesis survival rate following prosthesis insertion was 100% up to 4-year follow-up. The prostheses in 11 of the 16 restored arches were structurally sound, exhibited favorable soft tissue response, esthetics, and patient satisfaction. Five IFCDPs (31.25%) in four patients exhibited porcelain veneer chipping. Chipping was minor in three prostheses (three patients) and was addressed intraorally with polishing (one prosthesis) or composite resin (two prostheses). One patient with maxillary and mandibular zirconia IFCDP exhibited major porcelain chipping fractures which had to be repaired in the laboratory. Function, esthetics, and patient satisfaction were not affected in three of the four fracture incidents. Median crestal bone loss was 0.1 mm (0.01-0.2 mm). The presence of parafunctional activity, the IFCDP as opposing dentition, and the absence of occlusal night guard were associated with all the incidents of ceramic chipping. CAD/CAM zirconia IFCDPs are viable prosthetic treatment after 2-4 years in function, but not without complications. The porcelain chipping/fracture was the most frequent technical complication, with a 31.25% chipping rate at the prosthesis level. Despite the technical complications, increased patient satisfaction was noted. © 2012 John Wiley & Sons A/S.

  12. 3D Metal Printing - Additive Manufacturing Technologies for Frameworks of Implant-Borne Fixed Dental Prosthesis.

    PubMed

    Revilla León, M; Klemm, I M; García-Arranz, J; Özcan, M

    2017-09-01

    An edentulous patient was rehabilitated with maxillary metal-ceramic and mandibular metal-resin implant-supported fixed dental prosthesis (FDP). Metal frameworks of the FDPs were fabricated using 3D additive manufacturing technologies utilizing selective laser melting (SLM) and electron beam melting (EBM) processes. Both SLM and EBM technologies were employed in combination with computer numerical control (CNC) post-machining at the implant interface. This report highlights the technical and clinical protocol for fabrication of FDPs using SLM and EBM additive technologies. Copyright© 2017 Dennis Barber Ltd.

  13. [Fatal complications following the implantation of artificial lense (author's transl)].

    PubMed

    Hamburg, A; Winkelman, J E

    1979-08-01

    The number of cataract operations with implantation of artificial lenses has been increasing in recent years. However, there is hardly any information available concerning possible serious consequences. While there are detailed reports on histopathological findings following conventional cataract operations, fatal complications of this technically complex intervention are only mentioned occasionally. There were 9 cases with serious complications in our polyclinic in 1976, and this report deals with the histopathological findings in 6 enucleated eyes. The authors warn against ill-considered decisions to perform a lens implantation.

  14. [Clinical development of the automatic implantable defibrillator over 35 years: A success story].

    PubMed

    Steinbeck, G

    2015-06-01

    After 12 years of development and experimental evaluation, the first automatic implantable cardioverter-defibrillator (ICD) was implanted in man on February 4, 1980. This overview describes the technical and functional developments over 35 years from a simple shock-box, weighing 292 g, to the sophisticated 80 g device of today, delivering graded therapy to sustained ventricular arrhythmias and biventricular stimulation to treat heart failure. Finally, a special tribute is given to Michel Mirowski, one of the inventors of the ICD, as scientist and physician dedicated to patient care.

  15. Repair of bone segment defects with surface porous fiber-reinforced polymethyl methacrylate (PMMA) composite prosthesis: histomorphometric incorporation model and characterization by SEM.

    PubMed

    Hautamäki, Mikko P; Aho, Allan J; Alander, Pasi; Rekola, Jami; Gunn, Jarmo; Strandberg, Niko; Vallittu, Pekka K

    2008-08-01

    Polymer technology has provided solutions for filling of bone defects in situations where there may be technical or biological complications with autografts, allografts, and metal prostheses. We present an experimental study on segmental bone defect reconstruction using a polymethylmethacrylate-(PMMA-) based bulk polymer implant prosthesis. We concentrated on osteoconductivity and surface characteristics. A critical size segment defect of the rabbit tibia in 19 animals aged 18-24 weeks was reconstructed with a surface porous glass fiber-reinforced (SPF) prosthesis made of polymethylmethacrylate (PMMA). The biomechanical properties of SPF implant material were previously adjusted technically to mimic the properties of normal cortical bone. A plain PMMA implant with no porosity or fiber reinforcement was used as a control. Radiology, histomorphometry, and scanning electron microscopy (SEM) were used for analysis of bone growth into the prosthesis during incorporation. The radiographic and histological incorporation model showed good host bone contact, and strong formation of new bone as double cortex. Histomorphometric evaluation showed that the bone contact index (BCI) at the posterior surface interface was higher with the SPF implant than for the control. The total appositional bone growth over the posterior surface (area %) was also stronger for the SPF implant than for controls. Both bone growth into the porous surface and the BCI results were related to the quality, coverage, and regularity of the microstructure of the porous surface. Porous surface structure enhanced appositional bone growth onto the SPF implant. Under load-bearing conditions the implant appears to function like an osteoconductive prosthesis, which enables direct mobilization and rapid return to full weight bearing.

  16. The rationale for the introduction of implant dentistry into the dental curriculum.

    PubMed

    Lang, N P; De Bruyn, H

    2009-02-01

    This paper provides arguments for the introduction of implant dentistry into the undergraduate curriculum. The survival of teeth is very high when disease is diagnosed and treated properly and maintenance is taken care of. Nevertheless, tooth replacements by fixed and removable prostheses are highly prevalent. It is expected that dentists will face a dramatically increased need to care for elderly patients and partially edentulous patients. Hence, the demand for implant reconstructions will be substantial and more appropriately trained and competent health professionals will be needed. Increasing demands of the patient regarding aesthetics and function will influence the demands for implant therapy. The improvement of oral function and subjective chewing comfort, the preservation of tooth structures or existing reconstructions and the replacement of missing, strategically important teeth are major indications for implant placement. From both a biological and an economical point of view, the single tooth replacement with an implant is the first choice in situations with no or minimally restored neighbouring teeth compared with conventional bridgework. Stability of full dentures represent a major problem especially for the mandible. It is well documented that placement of two implants supporting an overdenture substantially improve chewing capacity, increase quality of life and is a simple and cost-effective treatment thus rendering such treatment a 'standard of care' procedure. There is no doubt that dental students should learn to incorporate the indication of oral implants in their overall treatment planning. Therefore, they will have to understand the basic aspects of healing and tissue integration, basic biomechanical and material science principles as well as surgical and prosthetic techniques. They will have to be able to monitor continuously the peri-implant tissues, render appropriate supportive therapy and cope with biological and technical complications. While it is evident that the surgical procedure per se may require additional competence, the remainder of the aspects mentioned should be taught in the dental curriculum. This should include the attribution of responsibility for maintenance of implants and handling of biological and technical complications. Moreover, it is desirable to include the surgical technique for implant placement for 'straightforward' cases into the dental curriculum. The levels and limitations to which the various aspects of implant dentistry and related skills are to be taught are determined by the academic community. Obviously, ethical and legal aspects of implant dentistry should not be forgotten.

  17. Managing peri-implant bone loss: current understanding.

    PubMed

    Aljateeli, Manar; Fu, Jia-Hui; Wang, Hom-Lay

    2012-05-01

    With the improved macro- and micro-designs, dental implants enjoy a high survival rate. However, peri-implant bone loss has recently emerged to be the focus of implant therapy. As such, researchers and clinicians are in need of finding predictable techniques to treat peri-implant bone loss and stop its progression. Literature search on the currently available treatment modalities was performed and a brief description of each modality was provided. Numerous techniques have been proposed and none has been shown to be superior and effective in managing peri-implant bone loss. This may be because of the complex of etiological factors acting on the implant-supported prosthesis hence the treatment approach has to be individually tailored. Due to the lack of high-level clinical evidence on the management of peri-implant bone loss, the authors, through a literature review, attempt to suggest a decision tree or guideline, based on sound periodontal surgical principles, to aid clinicians in managing peri-implantitis associated bone loss. © 2011 Wiley Periodicals, Inc.

  18. The role of hinges in primary total knee replacement.

    PubMed

    Gehrke, T; Kendoff, D; Haasper, C

    2014-11-01

    The use of hinged implants in primary total knee replacement (TKR) should be restricted to selected indications and mainly for elderly patients. Potential indications for a rotating hinge or pure hinge implant in primary TKR include: collateral ligament insufficiency, severe varus or valgus deformity (>20°) with necessary relevant soft-tissue release, relevant bone loss including insertions of collateral ligaments, gross flexion-extension gap imbalance, ankylosis, or hyperlaxity. Although data reported in the literature are inconsistent, clinical results depend on implant design, proper technical use, and adequate indications. We present our experience with a specific implant type that we have used for over 30 years and which has given our elderly patients good mid-term results. Because revision of implants with long cemented stems can be very challenging, an effort should be made in the future to use shorter stems in modular versions of hinged implants. ©2014 The British Editorial Society of Bone & Joint Surgery.

  19. Calf Augmentation and Restoration: Long-Term Results and the Review of the Reported Complications.

    PubMed

    Niechajev, Igor; Krag, Christen

    2017-10-01

    Augmentation or reconstruction of the calves is indicated in patients with thin legs, for bodybuilders, or when there is a defect after an injury or illness. The principle of placing implants under the investing crural fascia was worked out in the 1980s. The senior author (I.N.) introduced many technical modifications and improvements for this operation, among them the new instrument, an inserter for the calf implants. Presented patient material is unique in that the more challenging reconstructive cases almost equal the numbers of the aesthetic cases. During the years 1991 through 2016, 50 patients underwent 60 calf contour corrections. Indications were aesthetic in 23 patients, six were bodybuilders, and 21 underwent lower leg reconstruction because of deformity caused by illness. According to evaluation by the surgeon, excellent-to-good results were obtained in 30 out of 37 followed patients. Patients rated their results as very good (18), good (10), acceptable (7) and bad (2). One 28-year-old professional bodybuilder sustained acute anterior compartment syndrome in one leg. Implants were removed 16 h after surgery, but he developed ischaemia in the anterior compartment leading to the necrosis of muscles. After several surgical operations, including microsurgical transfer of the innervated central caput of the quadriceps femoris muscle, he could resume his bodybuilding activities. Other complications were minor and manageable. Calf augmentation, performed properly, has evolved to be a safe, efficient and aesthetically pleasing operation. The possibility of acute compartment syndrome should be kept in mind. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  20. First clinical results of minimally invasive vector lumbar interbody fusion (MIS-VLIF) in spondylodiscitis and concomitant osteoporosis: a technical note.

    PubMed

    Rieger, Bernhard; Jiang, Hongzhen; Ruess, Daniel; Reinshagen, Clemens; Molcanyi, Marek; Zivcak, Jozef; Tong, Huaiyu; Schackert, Gabriele

    2017-12-01

    First description of MIS-VLIF, a minimally invasive lumbar stabilization, to evaluate its safety and feasibility in patients suffering from weak bony conditions (lumbar spondylodiscitis and/or osteoporosis). After informed consent, 12 patients suffering from lumbar spondylodiscitis underwent single level MIS-VLIF. Eight of them had a manifest osteoporosis, either. Pre- and postoperative clinical status was documented using numeric rating scale (NRS) for leg and back pain. In all cases, the optimal height for the cage was preoperatively determined using software-based range of motion and sagittal balance analysis. CT scans were obtained to evaluate correct placement of the construct and to verify fusion after 6 months. Since 2013, 12 patients with lumbar pyogenic spondylodiscitis underwent MIS-VLIF. Mean surgery time was 169 ± 28 min and average blood loss was less than 400 ml. Postoperative CT scans showed correct placement of the implants. Eleven patients showed considerable postoperative improvement in clinical scores. In one patient, we observed screw loosening. After documented bony fusion in the CT scan, the fixation system was removed in two cases to achieve lower material load. The load-bearing trajectories (vectors) of MIS-VLIF are different from those of conventional coaxial pedicle screw implantation. The dorsally converging construct combines the heads of the dorsoventral pedicle screws with laminar pedicle screws following cortical bone structures within a small approach. In case of lumbar spondylodiscitis and/or osteoporosis, MIS-VLIF relies on cortical bony structures for all screw vectors and the construct does not depend on conventional coaxial pedicle screws in the presence of inflamed, weak, cancellous or osteoporotic bone. MIS-VLIF allows full 360° lumbar fusion including cage implantation via a small, unilateral dorsal midline approach.

  1. Current Trends in the Oncologic and Surgical Managements of Breast Cancer in Women with Implants: Incidence, Diagnosis, and Treatment.

    PubMed

    Veronesi, Paolo; De Lorenzi, Francesca; Loschi, Pietro; Rietjens, Mario; Veronesi, Umberto

    2016-04-01

    Breast augmentation is the most common cosmetic surgery in the United States, and thousands of augmented patients develop breast cancer each year. The possible effects of implants on cancer incidence, diagnosis, and treatment usually generate a disarming confusion. The present paper represents an update of the more recent oncologic and surgical strategies, aiming to support plastic and general surgeons in such challenging aspects. Several aspects of breast cancer management in augmented women are investigated, including (1) risk estimation and cancer characteristics, stage at diagnosis, and prognosis; (2) cancer diagnosis with clinical examination, mammography, ultrasound, and magnetic resonance imaging; (3) cancer treatment including breast conservation, intraoperative radiotherapy, sentinel node biopsy and mastectomy, and reconstruction. A brief resume of recommendations and conclusions is suggested, elucidating correct trends in the oncologic management of augmented patients and refusing well-established misconceptions: (1) breast augmentation does not increase the risk of breast cancer incidence, and it does not influence the prognosis; (2) possible risks exist in cancer detection due to technical difficulties; (3) sentinel lymph node detection is feasible; (4) intraoperative radiotherapy represents a good chance for conserving treatment; (5) immediate reconstruction with submuscular-subfascial implants is the most common procedure after mastectomy, and biological substitutes could support this procedure. Breast clinicians should be alerted because of high expectations of this subgroup of patients, accustomed to emphasize the aesthetic result. This journal requires that the authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.

  2. Characterization of Breast Implant Surfaces, Shapes, and Biomechanics: A Comparison of High Cohesive Anatomically Shaped Textured Silicone, Breast Implants from Three Different Manufacturers.

    PubMed

    Atlan, Michael; Bigerelle, Maxence; Larreta-garde, Véronique; Hindié, Mathilde; Hedén, Per

    2016-02-01

    Several companies offer anatomically shaped breast implants but differences among manufacturers are often misunderstood. The shell texture is a crucial parameter for anatomically shaped implants to prevent rotation and to decrease the risk of capsular contracture, even though concerns have recently been raised concerning the complications associated with textured breast implants. The aim of this study was to characterize differences in terms of texture, cell adhesion, shape, and stiffness between some commonly used anatomically shaped implants from three different manufacturers. Five commercially available anatomically shaped breast implants from 3 different manufacturers (Allergan, Mentor, and Sebbin) were used. Scanning electron microscopy, X-ray microtomography, and scanning mechanical microscopy were used to characterize the shell texture. Human fibroblast adhesion onto the shells was evaluated. 3D models of the implants were obtained using CT-scan acquisitions to analyze their shape. Implant stiffness was evaluated using a tractiometer. Major differences were observed in the topography of the textures of the shells, but this was not conveyed by a statistically significant fibroblast adhesion difference. However, fibroblasts adhered better on anatomically shaped textured implants than on smooth implants (p < 0.01). Our work pointed out differences in the Biocell® texture in comparison with older studies. The 3D analysis showed significant shape differences between the anatomically shaped implants of the 3 companies, despite similar dimensions. Implant stiffness was comparable among the 3 brands. Each texture had its specific topography, and this work is the first description of Sebbin anatomic breast implant texturation. Moreover, major discrepancies were found in the analysis of the Biocell® texture when comparing our results with previous reports. These differences may have clinical implications and are discussed. This study also highlighted major shape differences among breast implants from different manufacturers, which is quite counterintuitive. The clinical impact of these differences however needs further investigation. This journal requires that authors assign a level of evidence to each submission to which Evidence-Based Medicine rankings are applicable. This excludes Review Articles, Book Reviews, and manuscripts that concern Basic Science, Animal Studies, Cadaver Studies, and Experimental Studies. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.

  3. Specifying Skill-Based Training Strategies and Devices: A Model Description

    DTIC Science & Technology

    1990-06-01

    Technical Report 897 Specifying Skill-Based Training N Strategies and Devices: A Model Description I Paui J. Sticha and Mark Schlager Human Resources...unlimied 90 ’ Technical Report 897 Specifying Skill-Based Training Strategies and Devices: A Model Description Paul J. Sticha and Mark Schlager Human...SECURITY CLASSIFICATION OF THIS PAGE Form Approved REPORT DOCUMENTATION PAGE FMNo o7 ote la. REPORT SECURITY CLASSIFICATION lb. RESTRICTWE MARKINGS

  4. [Simultaneous double prosthesis implant more artificial urinary sphincter via transscrotal: surgical technique].

    PubMed

    Martínez-Salamanca, Juan Ignacio; Moncada, Ignacio; del Portillo, Luis; Sola, Ignacio; Martínez-Ballesteros, Claudio; Carballido, Joaquín

    2011-04-01

    Moderate-severe urinary incontinence and refractory-to-treatment erectile dysfunction after radical prostatectomy are two entities causing an important loss of quality of life to patients. The double implant of penile prosthesis and artificial urinary sphincter is a safe and effective option in these cases. This article describes preoperative considerations and the most important technical steps to do it satisfactorily.

  5. Predictability of short implants (< 10 mm) as a treatment option for the rehabilitation of atrophic maxillae. A systematic review

    PubMed Central

    García-Sala-Bonmatí, Fernando; Martínez-González, Amparo; García-Dalmau, Carlos; Mañes-Ferrer, José-Félix; Brotons-Oliver, Alejandro

    2016-01-01

    Background Short implants (< 10 mm) are one of the treatment options available in cases of limited vertical bone. A purpose of this paper is to evaluate the predictability of short implants as an alternative to technically molthough such implants are now widely used, there is controversy regarding their clinical reliability. There complex treatments in patients with atrophic maxillae, based on a systematic review of the literature and the analysis of the implant survival rates, changes in peri-implant bone level, and associated complications. It is postulated that short implants offer clinical results similar to those of longer implants. Material and Methods A Medline-PubMed search was made covering the period between January 2004 and December 2014 (both included). Studies in English published in indexed journals, involving at least 20 implants and with a follow-up period of at least 12 months were considered. A manual search in four high impact journals was also conducted. Results A total of 37 studies meeting the inclusion criteria were included in this review. 9792 implants placed in over 5000 patients were analyzed. Conclusions Based on the results of this review, short implants are seen to offer clinical results in terms of survival, bone loss and complications similar to those of longer implants. Key words:Survival rate, clinical results, dental implants, oral implants, short implants, short lengt PMID:26946199

  6. Polymeric Packaging for Fully Implantable Wireless Neural Microsensors

    PubMed Central

    Aceros, Juan; Yin, Ming; Borton, David A.; Patterson, William R.; Bull, Christopher; Nurmikko, Arto V.

    2014-01-01

    We present polymeric packaging methods used for subcutaneous, fully implantable, broadband, and wireless neurosensors. A new tool for accelerated testing and characterization of biocompatible polymeric packaging materials and processes is described along with specialized test units to simulate our fully implantable neurosensor components, materials and fabrication processes. A brief description of the implantable systems is presented along with their current encapsulation methods based on polydimethylsiloxane (PDMS). Results from in-vivo testing of multiple implanted neurosensors in swine and non-human primates are presented. Finally, a novel augmenting polymer thin film material to complement the currently employed PDMS is introduced. This thin layer coating material is based on the Plasma Enhanced Chemical Vapor Deposition (PECVD) process of Hexamethyldisiloxane (HMDSO) and Oxygen (O2). PMID:23365999

  7. Health, Maintenance, and Recovery of Soft Tissues around Implants.

    PubMed

    Wang, Yulan; Zhang, Yufeng; Miron, Richard J

    2016-06-01

    The health of peri-implant soft tissues is one of the most important aspects of osseointegration necessary for the long-term survival of dental implants. To review the process of soft tissue healing around osseointegrated implants and discuss the maintenance requirements as well as the possible short-comings of peri-implant soft tissue integration. Literature search on the process involved in osseointegration, soft tissue healing and currently available treatment modalities was performed and a brief description of each process was provided. The peri-implant interface has been shown to be less effective than natural teeth in resisting bacterial invasion because gingival fiber alignment and reduced vascular supply make it more vulnerable to subsequent peri-implant disease and future bone loss around implants. And we summarized common procedures which have been shown to be effective in preventing peri-implantitis disease progression as well as clinical techniques utilized to regenerate soft tissues with bone loss in advanced cases of peri-implantitis. Due to the difference between peri-implant interface and natural teeth, clinicians and patients should pay more attention in the maintenance and recovery of soft tissues around implants. © 2015 Wiley Periodicals, Inc.

  8. Energy Savings Potential and Research, Development, & Demonstration Opportunities for Commercial Building Heating, Ventilation, and Air Conditioning Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2011-09-01

    This report covers an assessment of 182 different heating, ventilation, and air-conditioning (HVAC) technologies for U.S. commercial buildings to identify and provide analysis on 17 priority technology options in various stages of development. The analyses include an estimation of technical energy-savings potential, description of technical maturity, description of non-energy benefits, description of current barriers for market adoption, and description of the technology’s applicability to different building or HVAC equipment types. From these technology descriptions, are suggestions for potential research, development and demonstration (RD&D) initiatives that would support further development of the priority technology options.

  9. Numerical FEM modeling in dental implantology

    NASA Astrophysics Data System (ADS)

    Roateşi, Iulia; Roateşi, Simona

    2016-06-01

    This paper is devoted to a numerical approach of the stress and displacement calculation of a system made up of dental implant, ceramic crown and surrounding bone. This is the simulation of a clinical situation involving both biological - the bone tissue, and non-biological - the implant and the crown, materials. On the other hand this problem deals with quite fine technical structure details - the threads, tapers, etc with a great impact in masticatory force transmission. Modeling the contact between the implant and the bone tissue is important to a proper bone-implant interface model and implant design. The authors proposed a three-dimensional numerical model to assess the biomechanical behaviour of this complex structure in order to evaluate its stability by determining the risk zones. A comparison between this numerical analysis and clinical cases is performed and a good agreement is obtained.

  10. Curriculum Development System for Navy Technical Training.

    ERIC Educational Resources Information Center

    Butler, Lucius

    Documentation for the U.S. Navy's curriculum development system is brought together in this paper, beginning with a description of the Naval Technical Training System. This description includes the Navy Training Plan (NTP) process, which is the current mechanism for introducing new courses; the organization and administration of the system; the…

  11. Piggyback transplantation with side-to-side cavocavostomy is an ideal technique for right split liver allograft implantation.

    PubMed

    Lerut, J; de Ville de Goyet, J; Donataccio, M; Reding, R; Otte, J B

    1994-11-01

    Split liver grafting has not gained wide acceptance mainly because of different vascular and biliary technical problems. A new technique of right split liver transplantation is described. The piggyback implantation technique, using wide side-to-side cavocavostomy overcomes problems encountered when sharing the superhepatic vena cava cuff between two livers and obtains optimal drainage of venous allograft outflow, thus avoiding extensive bleeding at the transection margin. This technique was successfully used in two adult recipients. Piggyback transplantation using wide side-to-side cavocavostomy allows easy and safe implantation of the right split liver allograft.

  12. A new surgical and technical approach in zygomatic implantology

    PubMed Central

    GRECCHI, F.; BIANCHI, A.E.; SIERVO, S.; GRECCHI, E.; LAURITANO, D.

    2017-01-01

    SUMMARY Purpose Different surgical approaches for zygomatic implantology using new designed implants are reported. Material and methods The surgical technique is described and two cases reported. The zygomatic fixture has a complete extrasinus path in order to preserve the sinus membrane and to avoid any post-surgical sinus sequelae. Results The surgical procedure allows an optimal position of the implant and consequently an ideal emergence of the fixture on the alveolar crest. Conclusion The surgical procedures and the zygomatic implant design reduce remarkably the serious post-operative sequelae due to the intrasinus path of the zygomatic fixtures. PMID:29876045

  13. Enabling personalized implant and controllable biosystem development through 3D printing.

    PubMed

    Nagarajan, Neerajha; Dupret-Bories, Agnes; Karabulut, Erdem; Zorlutuna, Pinar; Vrana, Nihal Engin

    The impact of additive manufacturing in our lives has been increasing constantly. One of the frontiers in this change is the medical devices. 3D printing technologies not only enable the personalization of implantable devices with respect to patient-specific anatomy, pathology and biomechanical properties but they also provide new opportunities in related areas such as surgical education, minimally invasive diagnosis, medical research and disease models. In this review, we cover the recent clinical applications of 3D printing with a particular focus on implantable devices. The current technical bottlenecks in 3D printing in view of the needs in clinical applications are explained and recent advances to overcome these challenges are presented. 3D printing with cells (bioprinting); an exciting subfield of 3D printing, is covered in the context of tissue engineering and regenerative medicine and current developments in bioinks are discussed. Also emerging applications of bioprinting beyond health, such as biorobotics and soft robotics, are introduced. As the technical challenges related to printing rate, precision and cost are steadily being solved, it can be envisioned that 3D printers will become common on-site instruments in medical practice with the possibility of custom-made, on-demand implants and, eventually, tissue engineered organs with active parts developed with biorobotics techniques. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. The safety of magnetic resonance imaging in patients with programmable implanted intrathecal drug delivery systems: a 3-year prospective study.

    PubMed

    De Andres, Jose; Villanueva, Vicente; Palmisani, Stefano; Cerda-Olmedo, German; Lopez-Alarcon, Maria Dolores; Monsalve, Vicente; Minguez, Ana; Martinez-Sanjuan, Vicente

    2011-05-01

    It is common clinical practice to perform magnetic resonance imaging (MRI) in patients with indwelling programmable intrathecal drug delivery (IDD) systems, although the safety of the procedure has never been documented. We performed a single-center, 3-year, prospective evaluation in patients with a programmable implanted IDD to assess patient discomfort, IDD technical failures, and adverse effects during and after exposure to MRI. Forty-three consecutive patients with an implanted programmable IDD system (SynchroMed® EL Implantable Infusion Pump, Model 8626L-18, and SynchroMed® II Model 8637-20, 8637-40; Medtronic, Inc., Minneapolis, MN) requiring a scheduled MRI evaluation were studied during a 3-year period. All MRI scans were performed with a 1.5-tesla clinical use magnet and a specific absorption rate of no more than 0.9 W/kg. Radiograph control was used to confirm postexposure pump rotor movement and detect system dislocations. IDD system failures, patient satisfaction, and discomfort were recorded. None of the patients experienced signs of drug overinfusion that could lead to hemodynamic, respiratory, or neurologic alterations. Radiologic evaluation after MRI revealed no spatial displacements of the intrathecal catheter tip or body pump, and programmer telemetry confirmed the infusion recovery. Patients' satisfaction after the procedure was high. Performing an MRI scan with the proposed protocol in patients with an implanted Medtronic programmable IDD system resulted in virtually no technical or medical complications. © 2011 International Anesthesia Research Society

  15. A Preoperative Planning Tool: Aggregate Anterior Approach to the Humerus With Quantitative Comparisons.

    PubMed

    Phelps, Kevin D; Harmer, Luke S; Crickard, Colin V; Hamid, Nady; Sample, Katherine M; Andrews, Erica B; Seymour, Rachel B; Hsu, Joseph R

    2018-06-01

    Extensile approaches to the humerus are often needed when treating complex proximal or distal fractures that have extension into the humeral shaft or in those fractures that occur around implants. The 2 most commonly used approaches for more complex fractures include the modified lateral paratricipital approach and the deltopectoral approach with distal anterior extension. Although the former is well described and quantified, the latter is often associated with variable nomenclature with technical descriptions that can be confusing. Furthermore, a method to expose the entire humerus through an anterior extensile approach has not been described. Here, we illustrate and quantify a technique for connecting anterior humeral approaches in a stepwise fashion to form an aggregate anterior approach (AAA). We also describe a method for further distal extension to expose 100% of the length of the humerus and compare this approach with both the AAA and the lateral paratricipital in terms of access to critical bony landmarks, as well as the length and area of bone exposed.

  16. Implant experience with an implantable hemodynamic monitor for the management of symptomatic heart failure.

    PubMed

    Steinhaus, David; Reynolds, Dwight W; Gadler, Fredrik; Kay, G Neal; Hess, Mike F; Bennett, Tom

    2005-08-01

    Management of congestive heart failure is a serious public health problem. The use of implantable hemodynamic monitors (IHMs) may assist in this management by providing continuous ambulatory filling pressure status for optimal volume management. The Chronicle system includes an implanted monitor, a pressure sensor lead with passive fixation, an external pressure reference (EPR), and data retrieval and viewing components. The tip of the lead is placed near the right ventricular outflow tract to minimize risk of sensor tissue encapsulation. Implant technique and lead placement is similar to that of a permanent pacemaker. After the system had been successfully implanted in 148 patients, the type and frequency of implant-related adverse events were similar to a single-chamber pacemaker implant. R-wave amplitude was 15.2 +/- 6.7 mV and the pressure waveform signal was acceptable in all but two patients in whom presence of artifacts required lead repositioning. Implant procedure time was not influenced by experience, remaining constant throughout the study. Based on this evaluation, permanent placement of an IHM in symptomatic heart failure patients is technically feasible. Further investigation is warranted to evaluate the use of the continuous hemodynamic data in management of heart failure patients.

  17. A retrospective study on clinical and radiological outcomes of oral implants in patients followed up for a minimum of 20 years.

    PubMed

    Chrcanovic, Bruno Ramos; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2018-04-01

    Very long-term follow-up of oral implants is seldom reported in the literature. To assess oral implant failure rates and marginal bone loss (MBL) of patients followed up for a minimum of 20 years. Implants placed in patients followed up for 20+ years were included. Descriptive statistics, survival analyses, generalized estimating equations were performed. Three-hundred implants were randomly selected for MBL. 1,045 implants (227 patients) were included. Implant location, irradiation, and bruxism affected the implant survival rate. Thirty-five percent of the failures occurred within the first year after implantation, and another 26.8% in the second/third year. There was a cumulative survival rate of 87.8% after 36 years of follow-up. In the last radiological follow up, 35 implants (11.7%) had bone gain, and 35 implants (11.7%) presented at least 3 mm of MBL. Twenty-six out of 86 failed implants with available radiograms presented severe MBL in the last radiological register before implant failure. Most of the implant failures occurred at the first few years after implantation, regardless of a very long follow up. MBL can be insignificant in long-term observations, but it may, nevertheless, be the cause of secondary failure of oral implants in some cases. © 2017 Wiley Periodicals, Inc.

  18. Spatial Release from Masking in Adults with Bilateral Cochlear Implants: Effects of Distracter Azimuth and Microphone Location

    ERIC Educational Resources Information Center

    Davis, Timothy J.; Gifford, René H.

    2018-01-01

    Purpose: The primary purpose of this study was to derive spatial release from masking (SRM) performance-azimuth functions for bilateral cochlear implant (CI) users to provide a thorough description of SRM as a function of target/distracter spatial configuration. The secondary purpose of this study was to investigate the effect of the microphone…

  19. Cognitive and emotional factors associated with elective breast augmentation among young women.

    PubMed

    Moser, Stephanie E; Aiken, Leona S

    2011-01-01

    The purpose of this research was to propose and evaluate a psychosocial model of young women's intentions to obtain breast implants and the preparatory steps taken towards having breast implant surgery. The model integrated anticipated regret, descriptive norms and image norms from the media into the theory of planned behaviour (TPB). Focus groups (n = 58) informed development of measures of outcome expectancies, preparatory steps and normative influence. The model was tested and replicated among two samples of young women who had ever considered getting breast implants (n = 200, n = 152). Intentions and preparatory steps served as outcomes. Model constructs and outcomes were initially assessed; outcomes were re-assessed 11 weeks later. Evaluative attitudes and anticipated regret predicted intentions; in turn, intentions, along with descriptive norms, predicted subsequent preparatory steps. Perceived risk (susceptibility, severity) of negative medical consequences of breast implants predicted anticipated regret, which predicted evaluative attitudes. Intentions and preparatory steps exhibited interplay over time. This research provides the first comprehensive model predicting intentions and preparatory steps towards breast augmentation surgery. It supports the addition of anticipated regret to the TPB and suggests mutual influence between intentions and preparatory steps towards a final behavioural outcome.

  20. MCFire model technical description

    Treesearch

    David R. Conklin; James M. Lenihan; Dominique Bachelet; Ronald P. Neilson; John B. Kim

    2016-01-01

    MCFire is a computer program that simulates the occurrence and effects of wildfire on natural vegetation, as a submodel within the MC1 dynamic global vegetation model. This report is a technical description of the algorithms and parameter values used in MCFire, intended to encapsulate its design and features a higher level that is more conceptual than the level...

  1. IDEA Technical Report No. 2. Description of Data Base, 1976-77.

    ERIC Educational Resources Information Center

    Cashin, William E.; Slawson, Hugh M.

    The data and computational procedures used by the IDEA system at Kansas State University (during the 1976-77 academic year) to interpret ratings of teacher performance are described in this technical report. The computations for each of the seven parts (evaluation, course description, students' self ratings, methods, additional questions,…

  2. IDEA Technical Report No. 3. Description of Data Base, 1977-78.

    ERIC Educational Resources Information Center

    Cashin, William E.; Slawson, Hugh M.

    The data and computational procedures used by the IDEA System during the 1977-78 academic year at Kansas State University to interpret ratings of teacher performance are described in this technical report. The computations for each of the seven parts (evaluation, course description, students' self-ratings, methods, additional questions, diagnostic…

  3. Qualitative Assessment of Speech Perception Performance of Early and Late Cochlear Implantees.

    PubMed

    Kant, Anjali R; Pathak, Sonal

    2015-09-01

    The present study aims to provide a qualitative description and comparison of speech perception performance using model based tests like multisyllabic lexical neighborhood test (MLNT) and lexical neighborhood test (LNT), in early and late implanted (prelingual) hearing impaired children using cochlear implants. The subjects comprised of cochlear implantees; Group I (early implantees)-n = 15, 3-6 years of age; mean age at implantation-3½ years. Group II (late implantees)-n = 15, 7-13 years of age; mean age at implantation-5 years. The tests were presented in a sound treated room at 70 dBSPL. The children were instructed to repeat the words on hearing them. Responses were scored as percentage of words correctly repeated. Their means were computed. The late implantees achieved higher scores for words on MLNT than those on LNT. This may imply that late implantees are making use of length cues in order to aid them in speech perception. The major phonological process used by early implantees was deletion and by the late implantees was substitution. One needs to wait until the child achieves a score of 20 % on LNT before assessing other aspects of his/her speech perception abilities. There appears to be a need to use speech perception tests which are based on theoretical empirical models, in order to enable us to give a descriptive analysis of post implant speech perception performance.

  4. Hearing rehabilitation with a binaural cochlear implant in a patient with Erdheim-Chester disease.

    PubMed

    Querat, Charlotte; Thai-Van, Hung; Durand, Denis Vital; Cotton, François; Gallego, Stéphane; Truy, Eric

    2015-09-01

    Erdheim-Chester disease (ECD) is a rare non-Langerhans form of histiocytosis. This paper reports an exceptional case of bilateral neural involvement, responsible for profound hearing loss. Bilateral cochlear implantation was performed. We present a 57-year-old man affected by ECD with profound bilateral hearing loss. The patient underwent cochlear implantation with a binaural Digisonic(®) cochlear implant, 7 years after the initial diagnosis. Speech intelligibility rose to a plateau after about 6 months of cochlear implant use. The average outcome of speech intelligibility over time was 55% for dissyllabic words without lip reading, and 70% for sentences. Perception score decreased before the patient died from ECD. A description of the ECD and its otological manifestations is presented. This paper reports the effective hearing rehabilitation of profound bilateral hearing loss by the means of a binaural Digisonic(®) cochlear implant.

  5. Osseointegrated Implant Applications in Cosmetic and Functional Skull Base Rehabilitation

    PubMed Central

    Benscoter, Brent J.; Jaber, James J.; Kircher, Matthew L.; Marzo, Sam J.; Leonetti, John P.

    2011-01-01

    This study discusses the indications, outcomes, and complications in patients that underwent osseointegrated implantation for skull base rehabilitation. We conducted a retrospective review of eight patients with skull base defects who had undergone implantation of a facial prosthetic retention device ± bone-anchored hearing aid at a tertiary academic referral center. Descriptive analysis of applications, techniques, outcomes, and complications were reviewed. The majority of patients were males (n = 6) with previously diagnosed skull base malignancy (n = 5) with an average age of 46 (range, 14 to 77). All patients received an implanted facial prosthetic device either for an aural (n = 7) or orbital (n = 1) prosthesis. There were only two complications that included infection (n = 1) and implant extrusion (n = 1). Osseointegrated implantation of abutments for anchoring prosthetic devices in patients for skull base rehabilitation provides an excellent cosmetic option with minimal complications. PMID:22451830

  6. Orbital Wall Reconstruction with Two-Piece Puzzle 3D Printed Implants: Technical Note

    PubMed Central

    Mommaerts, Maurice Y.; Büttner, Michael; Vercruysse, Herman; Wauters, Lauri; Beerens, Maikel

    2015-01-01

    The purpose of this article is to describe a technique for secondary reconstruction of traumatic orbital wall defects using titanium implants that act as three-dimensional (3D) puzzle pieces. We present three cases of large defect reconstruction using implants produced by Xilloc Medical B.V. (Maastricht, the Netherlands) with a 3D printer manufactured by LayerWise (3D Systems; Heverlee, Belgium), and designed using the biomedical engineering software programs ProPlan and 3-Matic (Materialise, Heverlee, Belgium). The smaller size of the implants allowed sequential implantation for the reconstruction of extensive two-wall defects via a limited transconjunctival incision. The precise fit of the implants with regard to the surrounding ledges and each other was confirmed by intraoperative 3D imaging (Mobile C-arm Systems B.V. Pulsera, Philips Medical Systems, Eindhoven, the Netherlands). The patients showed near-complete restoration of orbital volume and ocular motility. However, challenges remain, including traumatic fat atrophy and fibrosis. PMID:26889349

  7. Epicardial cardioverter-defibrillator implantation in a 4-month-old infant bridged to heart transplantation.

    PubMed

    Carro, Cristina; Cereda, Alberto Francesco; Annoni, Giuseppe; Marianeschi, Stefano Maria

    2017-11-01

    Implantable cardioverter-defibrillator (ICD) is the gold standard therapy for the prevention of sudden cardiac death. Nevertheless, ICD placement in the paediatric population is still limited because of several technical difficulties. Several implantation techniques have been proposed but experience in infants with very low weight and less than 6 months is very limited. We herein describe a case of a minimally invasive ICD epicardial implantation in a 4-month-old infant weighing 5 kg. A diagnosis of arrhythmic cardiomyopathy with left ventricular non-compaction disease with ventricular tachycardia storms, QT prolongation and Wolff-Parkinson-White pattern was made. Antiarrhythmic drugs, radiofrequency ablation and sympathetic denervation were not effective. ICD implantation was successful allowing the infant to survive and bridging to heart transplantation. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  8. Use of Synthetic Osteochondral Implants to Treat Bilateral Shoulder Osteochondritis Dissecans in a Dog.

    PubMed

    Danielski, Alan; Farrell, Michael

    2018-06-20

     An 8-month-old American Bulldog was presented for assessment of bilateral thoracic limb lameness. Computed tomographic imaging revealed large, deep osteochondritis dissecans lesions in both humeral heads.  The osteochondritis dissecans lesions were debrided and the exposed subchondral defects were prepared to receive synthetic grafts. Circular implants consisting of a surface layer of polycarbonate urethane and a deep layer of lattice-type titanium were implanted into the osteochondral defects to reconstruct the articular surface topography. Follow-up clinical examination 1.5, 3 and 9months postoperatively revealed a lack of signs of shoulder pain and resolution of thoracic limb lameness. Nine-month follow-up radiographs showed radiographic evidence of osteointegration of both implants.  Synthetic osteochondral implantation in the caudocentral aspect of the humeral head appeared technically feasible and effective in resolving lameness caused by humeral head osteochondritis dissecans. Schattauer GmbH Stuttgart.

  9. [Comperative study of implant surface characteristics].

    PubMed

    Katona, Bernadett; Daróczi, Lajos; Jenei, Attila; Bakó, József; Hegedus, Csaba

    2013-12-01

    The osseointegration between the implant and its' bone environment is very important. The implants shall meet the following requirements: biocompatibility, rigidity, resistance against corrosion and technical producibility. In our present study surface morphology and material characteristics of different implants (Denti Bone Level, Denti Zirconium C, Bionika CorticaL, Straumann SLA, Straumann SLA Active, Dentsply Ankylos and Biotech Kontact implant) were investigated with scanning electron microscopy and energy-dispersive X-ray spectroscopy. The possible surface alterations caused by the manufacturing technology were also investigated. During grit-blasting the implants' surface is blasted with hard ceramic particles (titanium oxide, alumina, calcium phosphate). Properties of blasting material are critical because the osseointegration of dental implants should not be hampered. The physical and chemical features of blasting particles could importantly affect the produced surfaces of implants. Titanium surfaces with micro pits are created after immersion in mixtures of strong acids. On surfaces after dual acid-etching procedures the crosslinking between fibrin and osteogenetic cells could be enhanced therefore bone formation could be directly facilitated on the surface of the implant. Nowadays there are a number of surface modification techniques available. These can be used as a single method or in combination with each other. The effect of the two most commonly used surface modifications (acid-etching and grit-blasting) on different implants are demonstrated in our investigation.

  10. Long-term Survival of Straumann Dental Implants with TPS Surfaces: A Retrospective Study with a Follow-up of 12 to 23 Years.

    PubMed

    Becker, Stephan T; Beck-Broichsitter, Benedicta E; Rossmann, Christian M; Behrens, Eleonore; Jochens, Arne; Wiltfang, Jörg

    2016-06-01

    The aim of this study was to evaluate the long-term dental implant survival rates of Straumann dental implants in a university hospital environment over 12 to 23 years. A total of 388 Straumann dental implants with titanium-sprayed surfaces (TPS) were inserted in 92 patients between 1988 and 1999 in the Department of Oral and Maxillofacial Surgery of the University Hospital Schleswig-Holstein in Kiel, and they were reevaluated with standardized clinical and radiological exams. Kaplan-Meier analyses were performed for individual factors. Cox proportional hazard regression analysis was used to detect the factors influencing long-term implant failure. The long-term implant survival rate was 88.03% after an observation time of 12.2 to 23.5 years. Cox regression revealed statistically significant influences of the International Team for Implantology (ITI) implantation type (p = .00354) and tobacco smoking (p = .01264) on implant failure. A proportion 82.8% of the patients with implant losses had a medical history of periodontitis. Peri-implantitis was diagnosed in 9.7% of the remaining implants in the long-term survey. This study emphasized the long-term rehabilitation capabilities of Straumann dental implants in complex cases. The survival rates after several years constitute important information for patients, as well as for clinicians, in deciding about different concepts of tooth replacement. Patient-related and technical factors - determined before implant placement - could help to predict the risk of implant loss. © 2015 Wiley Periodicals, Inc.

  11. Current indications for stentless aortic bioprostheses.

    PubMed

    Hegazy, Yasser Y; Rayan, Amr; Bauer, Stefan; Keshk, Noha; Bauer, Kerstin; Ennker, Ina; Ennker, Jürgen

    2018-01-01

    The best aortic prostheses have been debated for decades. The introduction of stentless aortic bioprostheses was aimed at improving hemodynamics and potentially the durability of aortic bioprostheses. Despite the good short- and long-term outcomes after implantation of stentless aortic bioprostheses, their use remains limited owing to the technically demanding implantation techniques. Nevertheless, stentless aortic bioprostheses might be of special benefit in certain indications, where they could be a valuable addition to the surgical armamentarium.

  12. The financial implications of endovascular aneurysm repair in the cost containment era.

    PubMed

    Stone, David H; Horvath, Alexander J; Goodney, Philip P; Rzucidlo, Eva M; Nolan, Brian W; Walsh, Daniel B; Zwolak, Robert M; Powell, Richard J

    2014-02-01

    Endovascular aneurysm repair (EVAR) is associated with significant direct device costs. Such costs place EVAR at odds with efforts to constrain healthcare expenditures. This study examines the procedure-associated costs and operating margins associated with EVAR at a tertiary care academic medical center. All infrarenal EVARs performed from April 2011 to March 2012 were identified (n = 127). Among this cohort, 49 patients met standard commercial instruction for use guidelines, were treated using a single manufacturer device, and billed to Medicare diagnosis-related group (DRG) 238. Of these 49 patients, net technical operating margins (technical revenue minus technical cost) were calculated in conjunction with the hospital finance department. EVAR implant costs were determined for each procedure. DRG 238-associated costs and length of stay were benchmarked against other academic medical centers using University Health System Consortium 2012 data. Among the studied EVAR cohort (age 75, 82% male, mean length of stay, 1.7 days), mean technical costs totaled $31,672. Graft implants accounted for 52% of the allocated technical costs. Institutional overhead was 17% ($5495) of total technical costs. Net mean total technical EVAR-associated operating margins were -$4015 per procedure. Our institutional costs and length of stay, when benchmarked against comparable centers, remained in the lowest quartile nationally using University Health System Consortium costs for DRG 238. Stent graft price did not correlate with total EVAR market share. EVAR is currently associated with significant negative operating margins among Medicare beneficiaries. Currently, device costs account for over 50% of EVAR-associated technical costs and did not impact EVAR market share, reflecting an unawareness of cost differential among surgeons. These data indicate that EVAR must undergo dramatic care delivery redesign for this practice to remain sustainable. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  13. Assistive hearing technologies among students with hearing impairment: factors that promote satisfaction.

    PubMed

    Rekkedal, Ann Mette

    2012-01-01

    Hearing technology can play an essential part in the education of deaf and hard-of-hearing children in inclusive schools. Few studies have examined these children's experiences with this technology. This article explores factors pertaining to children's use of and attitudes toward hearing technologies, such as hearing aids, cochlear implants, teacher-worn microphones, and student-worn microphones. The study included 153 deaf and hard-of-hearing students. All students communicated orally and were in inclusive schools from grades 5-10. The results suggest that males view hearing technology more positively than do females. Having severe hearing loss also promoted positive attitudes toward hearing aids and cochlear implants, but not toward microphones. The students with positive self-descriptions tended to be more satisfied with hearing aids or cochlear implants than the students with negative self-descriptions. The main factors promoting the use of hearing aids were severe hearing loss, positive attitudes toward hearing aids, and the sound quality of hearing aids.

  14. Potential Bone to Implant Contact Area of Short Versus Standard Implants: An In Vitro Micro-Computed Tomography Analysis.

    PubMed

    Quaranta, Alessandro; DʼIsidoro, Orlando; Bambini, Fabrizio; Putignano, Angelo

    2016-02-01

    To compare the available potential bone-implant contact (PBIC) area of standard and short dental implants by micro-computed tomography (μCT) assessment. Three short implants with different diameters (4.5 × 6 mm, 4.1 × 7 mm, and 4.1 × 6 mm) and 2 standard implants (3.5 × 10 mm and 3.3 × 9 mm) with diverse design and surface features were scanned with μCT. Cross-sectional images were obtained. Image data were manually processed to find the plane that corresponds to the most coronal contact point between the crestal bone and implant. The available PBIC was calculated for each sample. Later on, the cross-sectional slices were processed by a 3-dimensional (3D) software, and 3D images of each sample were used for descriptive analysis and display the microtopography and macrotopography. The wide-diameter short implant (4.5 × 6 mm) showed the higher PBIC (210.89 mm) value followed by the standard (178.07 mm and 185.37 mm) and short implants (130.70 mm and 110.70 mm). Wide-diameter short implants show a surface area comparable with standard implants. Micro-CT analysis is a promising technique to evaluate surface area in dental implants with different macrodesign, microdesign, and surface features.

  15. Peri-Implant Crevicular Fluid Analysis, Enzymes and Biomarkers: a Systemetic Review

    PubMed Central

    Dursun, Erhan

    2016-01-01

    ABSTRACT Objectives To review the current understanding of the biomarkers and enzymes associated with different forms peri-implant diseases and how their level changes influence the pathogenesis of the inflammatory diseases around dental implants. Material and Methods An electronic search in two different databases was performed including MEDLINE (PubMed) and EMBASE between 1996 to 2016. Human studies analyse peri-implant crevicular fluid (PICF) biomarker and enzyme levels of implants having peri-implant mucositis and peri-implantitis published in English language, were evaluated. A systematic review was performed to assess which biomarkers and enzymes in PICF were used to identify the inflammatory conditions around dental implants. Results Fifty-one articles were identified of which 41 were further evaluated and included in the analysis. Due to significant heterogeneity between included studies, a meta-analysis could not be performed. Instead, a systematic descriptive review was performed. Conclusions Biomarkers and enzymes in peri-implant crevicular fluid have shown promising results in differentiating from peri-implant disease condition to health. However, due to inconsistent results and acquiring much evidence from cross-sectional studies, additional evidence supported by randomized-controlled trials is needed to validate the links reported. PMID:27833734

  16. Sleep and daytime sleepiness of patients with left ventricular assist devices: a longitudinal pilot study.

    PubMed

    Casida, Jesus M; Davis, Jean E; Brewer, Robert J; Smith, Cheryl; Yarandi, Hossein

    2011-06-01

    No empirical longitudinal data on sleep and daytime sleepiness patterns in patients with an implantable left ventricular assist device (LVAD) exist. (1) To describe the sleep patterns (sleep onset latency, sleep efficiency, sleep fragmentation index, total sleep time, and wake after sleep onset), sleep quality, and daytime sleepiness variables and (2) to determine the change in the pattern of these variables before and up to 6 months after LVAD implantation. A longitudinal descriptive repeated-measures design was used. Patients wore wrist actigraphs (AW64 Actiwatch), which objectively measured sleep, for 3 consecutive days and nights before LVAD implant and at the first and second week and first, third, and sixth month after implantation. During these periods, patients also completed questionnaires on sleep quality and daytime sleepiness. Patients-Twelve of 15 patients completed the 6-month data. Data were analyzed by using descriptive statistics and repeated-measures analysis of variance. We found long sleep onset latencies and low sleep efficiency across time periods. High sleep fragmentation index was noted at baseline and 1 week after LVAD. Short total sleep times, long wake-after-sleep-onset durations, and poor sleep quality were evident at baseline and persisted up to 6 months after LVAD implantation. Low alertness level, a manifestation of sleepiness, was common during late morning to early evening hours. However, only sleep efficiency and wake after sleep onset showed significant changes in pattern (P < .05). Sleep disturbance and daytime sleepiness may be prevalent before and up to 6 months after LVAD implantation, warranting further investigation.

  17. Wearable cardioverter defibrillator: Bridge or alternative to implantation?

    PubMed Central

    Barraud, Jeremie; Cautela, Jennifer; Orabona, Morgane; Pinto, Johan; Missenard, Olivier; Laine, Marc; Thuny, Franck; Paganelli, Franck; Bonello, Laurent; Peyrol, Michael

    2017-01-01

    The implantable cardioverter-defibrillator (ICD) is effective to prevent sudden cardiac death (SCD) in selected patients with heart disease known to be at high risk for ventricular arrhythmia. Nevertheless, this invasive and definitive therapy is not indicated in patients with potentially transient or reversible causes of sudden death, or in patients with temporary contra-indication for ICD placement. The wearable cardioverter defibrillator (WCD) is increasingly used for SCD prevention both in patients awaiting ICD implantation or with an estimated high risk of ventricular arrhythmia though to be transient. We conducted a review of current clinical uses and benefits of the WCD, and described its technical aspects, limitations and perspectives. PMID:28706588

  18. [Carbon fiber-reinforced plastics as implant materials].

    PubMed

    Bader, R; Steinhauser, E; Rechl, H; Siebels, W; Mittelmeier, W; Gradinger, R

    2003-01-01

    Carbon fiber-reinforced plastics have been used clinically as an implant material for different applications for over 20 years.A review of technical basics of the composite materials (carbon fibers and matrix systems), fields of application,advantages (e.g., postoperative visualization without distortion in computed and magnetic resonance tomography), and disadvantages with use as an implant material is given. The question of the biocompatibility of carbon fiber-reinforced plastics is discussed on the basis of experimental and clinical studies. Selected implant systems made of carbon composite materials for treatments in orthopedic surgery such as joint replacement, tumor surgery, and spinal operations are presented and assessed. Present applications for carbon fiber reinforced plastics are seen in the field of spinal surgery, both as cages for interbody fusion and vertebral body replacement.

  19. Biomechanical effects of a 2 suture-pass medial inter-implant mattress on transosseous-equivalent rotator cuff repair and considerations for a "technical efficiency ratio".

    PubMed

    Park, Maxwell C; Peterson, Alexander; Patton, John; McGarry, Michelle H; Park, Chong J; Lee, Thay Q

    2014-03-01

    Rotator cuff repair involving fewer tendon suture passes without compromising biomechanical performance would represent a technical advancement. An inter-implant "medial pulley-mattress" transosseous-equivalent (MP-TOE) repair requiring fewer tendon suture-passes was hypothesized to provide equivalent biomechanical characteristics compared to the control. In 6 human cadaveric shoulders, a transosseous-equivalent (TOE) repair (control) was performed utilizing 2 separate medial mattresses resulting in 4 tendon-bridging sutures. In 6 matched-pairs, 2 single-loaded anchors were used to create a medial inter-implant mattress construct (all sutures shuttled in 1 tendon pass per anchor)-after knot-tying, the same tendon-bridging pattern as the control was created. A materials testing machine cyclically loaded each repair from 10-180 N for 30 cycles; each repair subsequently underwent failure testing. Gap and strain were measured with a video digitizing system. A "technical efficiency ratio" (TER) was defined as: (#knots + #suture passes + #suture limbs)/#fixation points. Cyclic and failure testing demonstrated no significant differences between constructs. Gap formation at cycle 30 was 5.3 ± 0.8 mm (TOE) and 5.0 ± 0.3 mm (MP-TOE) (P = .62). Cycle 30 anterior strain values were -16.0 ± 7.3% (TOE) and -15.8 ± 6.6% (MP-TOE) (P = .99). Yield loads were 208.7 ± 2.7 N (TOE) and 204.0 ± 1.3 N (MP-TOE) (P = .17). Mode of failure demonstrated less tendon cut-out with the MP-TOE repair. The MP-TOE repair has a TER of 2.0 vs 2.5 for the control. The MP-TOE repair requiring fewer tendon suture passes, yet creating an additional inter-implant mattress configuration, is biomechanically equivalent to the original TOE technique, and may limit failure with improved medial load-sharing capacity. A TER may help quantify technical ease and help standardize comparisons between repair techniques. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.

  20. Survival of dental implants placed in sites of previously failed implants.

    PubMed

    Chrcanovic, Bruno R; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2017-11-01

    To assess the survival of dental implants placed in sites of previously failed implants and to explore the possible factors that might affect the outcome of this reimplantation procedure. Patients that had failed dental implants, which were replaced with the same implant type at the same site, were included. Descriptive statistics were used to describe the patients and implants; survival analysis was also performed. The effect of systemic, environmental, and local factors on the survival of the reoperated implants was evaluated. 175 of 10,096 implants in 98 patients were replaced by another implant at the same location (159, 14, and 2 implants at second, third, and fourth surgeries, respectively). Newly replaced implants were generally of similar diameter but of shorter length compared to the previously placed fixtures. A statistically significant greater percentage of lost implants were placed in sites with low bone quantity. There was a statistically significant difference (P = 0.032) in the survival rates between implants that were inserted for the first time (94%) and implants that replaced the ones lost (73%). There was a statistically higher failure rate of the reoperated implants for patients taking antidepressants and antithrombotic agents. Dental implants replacing failed implants had lower survival rates than the rates reported for the previous attempts of implant placement. It is suggested that a site-specific negative effect may possibly be associated with this phenomenon, as well as the intake of antidepressants and antithrombotic agents. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Implant-Assisted Removable Partial Denture Prostheses: A Critical Review of Selected Literature.

    PubMed

    Bassetti, Renzo G; Bassetti, Mario A; Kuttenberger, Johannes

    A critical review of selected relevant publications assessed clinical efficacy and effectiveness of implant-assisted removable partial dentures (IARPDs) with implant survival and failure rates, biologic and technical complications, and maintenance and patient satisfaction after rehabilitation as outcomes. Screening of three databases (Medline [PubMed], Embase [OVID], and the Cochrane Library [CENTRAL]) and a manual search of related articles were performed. Reports on outcomes from human studies conducted between 1 January 1980 and 31 May 2016 were considered. A quality assessment of the identified full-text articles was performed to assess risk of bias and to evaluate heterogeneity. Only nine studies were included, and all nine demonstrated high risk of bias. The mean observation period ranged from 1 to 10 years, and only four studies included at least one control group. The studies reported implant survival rates of 91.7% to 100%, abutment tooth survival rates of 79.2% to 100%, and prosthesis survival rates of 90% to 100%. Approximal peri-implant crestal bone level changes (ΔCBL) ranged from -0.17 to -2.2 mm. IARPDs were associated with a higher frequency of technical complications and maintenance interventions than biologic complications. Only two question-based studies assessed patient satisfaction before and after treatment, and both reported marked improvement. A meta-analysis was not possible because of substantial heterogeneity in study design. Limited availability of robust publications related to the selected review topic precluded significant conclusions. Nonetheless, the preliminary assessment suggests that IARPDs are a simple and cost-effective approach to providing symmetric prosthesis support and stability, plus improved patient satisfaction.

  2. Wide-awake Anesthesia No Tourniquet Trapeziometacarpal Joint Prosthesis Implantation.

    PubMed

    Müller, Camillo Theo; Christen, Thierry; Heidekruger, Paul I; Lamouille, Jessie; Raffoul, Wassim; McKee, Daniel; Lalonde, Donald H; Durand, Sébastien

    2018-04-01

    Wide awake local anesthesia no tourniquet (WALANT) hand surgery is a rapidly growing in popularity. WALANT has been used by hand surgeons when operating on bones, tendons, ligaments, nerve entrapments. We offer a case report of the first case in the literature describing WALANT technique when performing trapeziometacarpal joint arthroplasty with prosthesis implantation. We offer technical points on how to perform this procedure and the advantages that are associated with using WALANT for prosthesis arthroplasty.

  3. Group D. Initiator paper. Implants--peri-implant (hard and soft tissue) interactions in health and disease: the impact of explosion of implant manufacturers.

    PubMed

    Ivanovski, Saso

    2015-01-01

    1. The best-documented implants have a threaded solid screw-type design and are manufactured from commercially pure (grade IV) titanium. There is good evidence to support implants ≥ 6 mm in length, and ≥ 3 mm in diameter. 2. Integrity of the seal between the abutment and the implant is important for several reasons, including minimization of mechanical and biological complications and maintaining marginal bone levels. Although the ideal design features of the implant-abutment connection have not been determined, an internal connection, micro-grooves at the implant collar, and horizontal offset of the implant-abutment junction (platform switch) appear to impart favorable properties. 3. Implants with moderately rough implant surfaces provide advantages over machined surfaces in terms of the speed and extent of osseointegration. While the favorable performances of both minimally and moderately rough surfaces are supported by long-term data, moderately rough surfaces provide superior outcomes in compromised sites, such as the posterior maxilla. 4. Although plaque is critical in the progression of peri-implantitis, the disease has a multi-factorial aetiology, and may be influenced by poor integrity of the abutment/implant connection. Iatrogenic factors, such as the introduction of a foreign body. (e.g., cement) below the mucosal margin, can be important contributors. 5. Clinicians should exercise caution when using a particular implant system, ensuring that the implant design is appropriate and supported by scientific evidence. Central to this is access to and participation in quality education on the impact that implant characteristics can have on clinical outcomes. Caution should be exercised in utilizing non-genuine restorative componentry that may lead to a poor implant-abutment fit and subsequent technical and biological complications.

  4. 48 CFR 2052.215-71 - Project officer authority.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... of the work description. (3) Review and, where required by the contract, approve technical reports... subject to the technical direction of the NRC project officer. The term technical direction is defined to include the following: (1) Technical direction to the contractor which shifts work emphasis between areas...

  5. 48 CFR 2052.215-71 - Project officer authority.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... of the work description. (3) Review and, where required by the contract, approve technical reports... subject to the technical direction of the NRC project officer. The term technical direction is defined to include the following: (1) Technical direction to the contractor which shifts work emphasis between areas...

  6. 48 CFR 2052.215-71 - Project officer authority.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... of the work description. (3) Review and, where required by the contract, approve technical reports... subject to the technical direction of the NRC project officer. The term technical direction is defined to include the following: (1) Technical direction to the contractor which shifts work emphasis between areas...

  7. 48 CFR 2052.215-71 - Project officer authority.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... of the work description. (3) Review and, where required by the contract, approve technical reports... subject to the technical direction of the NRC project officer. The term technical direction is defined to include the following: (1) Technical direction to the contractor which shifts work emphasis between areas...

  8. The Marshall Engineering Thermosphere (MET) Model. Volume 1; Technical Description

    NASA Technical Reports Server (NTRS)

    Smith, R. E.

    1998-01-01

    Volume 1 presents a technical description of the Marshall Engineering Thermosphere (MET) model atmosphere and a summary of its historical development. Various programs developed to augment the original capability of the model are discussed in detail. The report also describes each of the individual subroutines developed to enhance the model. Computer codes for these subroutines are contained in four appendices.

  9. Influence of implant location on the clinical outcomes of implant abutments: a systematic review and meta-analysis

    PubMed Central

    ElHoussiney, Amr G; Zhang, He; Song, Jinlin; Ji, Ping; Wang, Lu; Yang, Sheng

    2018-01-01

    Purpose To compare the failure events and incidence of complications of different abutment materials in anterior and posterior regions. Failure was defined as complete loss of the abutment requiring replacement by a new abutment. Materials and methods Electronic searches using PubMed/Medline and Google Scholar complemented with manual searches were performed with specific search terms. Searches were restricted to publications in English between January 2006 and March 2016. Results A total of 863 and 1,264 implants were inserted in the anterior and posterior regions, respectively, in a total of 1,529 patients. No titanium abutments failed in anterior or posterior regions. On the other hand, 1.6% of zirconia abutments failed in the anterior region and 1.5% failed in the posterior region. Technical complications occurred mostly in the posterior region and mostly involved zirconia abutment. Meta-analysis was possible only for zirconia-abutment failure, due to considerable heterogeneity of studies and outcome variables. No significant difference in failure rate was found between anterior and posterior zirconia abutments (risk ratio 1.53, 95% CI 0.49–4.77; P=0.47). Conclusion This systematic review and meta-analysis showed similar outcomes of different abutment materials when used in anterior and posterior regions in terms of failure events and biological and aesthetic complications. The only significant finding was the increased incidence of technical complications in the posterior region, mostly involving zirconia abutments. Abutment-screw loosening was the most common technical complication. PMID:29520162

  10. NATO Scientific and Technical Information Service (NSTIS): functional description. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Molholm, K.N.; Blados, W.N.; Bulca, C.

    1987-08-01

    This report provides a functional description of the requirements for a NATO Scientific and Technical Information Service (NSTIS). The user requirements and much of the background information in this report were derived primarily from interviews with more than 60 NATO Headquarters staff members between 2 March and 25 March 1987. In addition, representatives of the Supreme Headquarters Applied Powers Europe (SHAPE) Technical Centre (STC), the Supreme Allied Commander Atlantic (Anti-Submarine Warfare Research) Centre (SACLANTCEN), the NATO Communications and Information Systems Agency (NACISA), The Advisory Group for Aerospace Research and Development (AGARD), the U.S. Defense Technical Information Center (DTIC), and themore » Technical Documentation Center for the Armed Forces in the Netherlands (TDCK), were interviewed, either in person or by telephone.« less

  11. Efficacy of a laparoscopic gastric restrictive device in an obese canine model.

    PubMed

    Guo, Xiaomei; Mattar, Samer G; Mimms, Scott E; Navia, Jose A; Kassab, Ghassan S

    2014-01-01

    Bariatric surgery using laparoscopic techniques is the most effective treatment for morbid obesity. The objective of the study is to assess the safety and efficacy of a novel laparoscopic reversible gastric restrictive (RGR) device in a group of obese dogs. An implant was also performed in a cadaver to assess implant feasibility in a human. Four obese mongrel dogs were subjected to RGR implantation for 3 months followed by recovery for an additional 6 weeks after device removal. Food intake, body weight, radiographic barium imaging, and gastric endoscopy were used to monitor RGR performance before implant, after implant, and implant removal. An additional RGR laparoscopic implantation procedure was performed in a human cadaver. The implanted obese dogs exhibited a significant decrease in food intake and body weight over 3 months with the RGR device. The reduction of food intake was sustained at an average of 46 % after implant and the excess weight loss reached an average of 75 % at the end of 12 weeks with recovery to approximately 78 % of baseline after 6 weeks of implant removal. Barium imaging and gastric endoscopy both confirmed passage for food through the restrictive device channel in the stomach. The RGR device was successfully implanted laparoscopically on the cadaver stomach in less than an hour. The RGR device is laparoscopically deliverable and removable with effective and sustainable weight loss over a 12-week period in an obese dog model. The implant is also technically feasible in man.

  12. Current use of implantable electrical devices in Sweden: data from the Swedish pacemaker and implantable cardioverter-defibrillator registry.

    PubMed

    Gadler, Fredrik; Valzania, Cinzia; Linde, Cecilia

    2015-01-01

    The National Swedish Pacemaker and Implantable Cardioverter-Defibrillator (ICD) Registry collects prospective data on all pacemaker and ICD implants in Sweden. We aimed to report the 2012 findings of the Registry concerning electrical devices implantation rates and changes over time, 1 year complications, long-term device longevity and patient survival. Forty-four Swedish implanting centres continuously contribute implantation of pacemakers and ICDs to the Registry by direct data entry on a specific website. Clinical and technical information on 2012 first implants and postoperative complications were analysed and compared with previous years. Patient survival data were obtained from the Swedish population register database. In 2012, the mean pacemaker and ICD first implantation rates were 697 and 136 per million inhabitants, respectively. The number of cardiac resynchronization therapy (CRT) first implantations/million capita was 41 (CRT pacemakers) and 55 (CRT defibrillators), with only a slight increase in CRT-ICD rate compared with 2011. Most device implantations were performed in men. Complication rates for pacemaker and ICD procedures were 5.3 and 10.1% at 1 year, respectively. Device and lead longevity differed among manufacturers. Pacemaker patients were older at the time of first implant and had generally worse survival rate than ICD patients (63 vs. 82% after 5 years). Pacemaker and ICD implantation rates seem to have reached a level phase in Sweden. Implantable cardioverter-defibrillator and CRT implantation rates are very low and do not reflect guideline indications. Gender differences in CRT and ICD implantations are pronounced. Device and patient survival rates are variable, and should be considered when deciding device type. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  13. Implant-supported single-tooth restorations. A 12-year prospective study.

    PubMed

    Donati, Mauro; Ekestubbe, Annika; Lindhe, Jan; Wennström, Jan L

    2016-10-01

    The aim of this study was to evaluate prospectively the 12-year outcome of implant-supported single-tooth restorations. Originally 45 self-tapping Astra Tech TiOblast ® ST-implants were installed by a two-stage protocol in 40 subjects requiring single-tooth prosthetic replacement for a missing tooth. Clinical and radiologic examinations were performed at completion of the prosthetic treatment 4-7 months after implant installation surgery and after 5 and 12 years in function. At 12 years 31 patients and 35 implants were available for evaluation. The overall failure rate after 12 years was 10.3% on the subject level and 9.1% on the implant level. The mean bone loss amounted to 0.67 mm (SD 2.20) on a subject level and 0.47 mm (1.72) on an implant level. Three subjects (10%) and three implants (8.6%) were diagnosed with peri-implantitis. Five subjects had experienced technical complications; three incidences of loosening of the abutment retention screw during the first 5 years and two minor porcelain fracture of the crown (two patients) between 5- and 12-years of follow-up. The findings reported in this 12-year prospective case series suggest that the use of the Astra Tech dental implants may be a valid treatment alternative for single-tooth replacement prostheses. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. 77 FR 20369 - Applications for New Awards; Centers for Independent Living-Training and Technical Assistance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-04

    ... Education ACTION: Notice. Overview Information Centers for Independent Living--Training and Technical.... Funding Opportunity Description Purpose of Program The purpose of the Training and Technical Assistance grant under the Centers for Independent Living program is to provide training and technical assistance...

  15. Unresolved Technical Issues in Fair Interest Measurement.

    ERIC Educational Resources Information Center

    Cole, Nancy S.

    The problem of sex differences in interest measurement involves many technical issues and procedures. The purpose of this paper is to provide a description of the technical problems involved in construction, scoring, and interpretation of interest measures as related to sex differences and to suggest guidelines within these technical issues which…

  16. Implant dentistry curriculum in undergraduate education: part 2-program at the Albert-Ludwigs University, Freiburg, Germany.

    PubMed

    Kroeplin, Birgit S; Strub, Joerg R

    2011-01-01

    The aim of this study was to describe the didactic and clinical undergraduate implant dentistry program of the Albert-Ludwigs University, Freiburg, Germany, with emphasis on the clinical implant experience. A detailed description of the implant curriculum at Albert-Ludwigs University is given with documented exemplary cases and additional flow charts. All students participate in 28 hours of lectures and approximately 64 hours of seminars with hands-on courses and gain clinical experience. All undergraduate students are eligible to place and restore oral implants. Emphasis is placed on prosthetic-driven planning of implant positions, three-dimensional imaging, and computer-guided implant placement. Implant restorations performed by undergraduate students comprise single crowns and small multiunit fixed dental prostheses in partially edentulous posterior maxillae and anterior or posterior mandibles, implant-retained overdentures (snap attachment) in edentulous patients, and telescopic fixed-removable dental prostheses on remaining teeth and strategically placed additional implants. Over the past 2.5 years, 51 patients were treated with 97 dental implants placed by students in the undergraduate program. Seventy-one restorations were inserted: 60.6% single crowns, 7% fixed dental protheses, 21.1% overdentures, and 11.3% telescopic fixed-removable dental prostheses. The implant survival rate was 98.9%. Because survival rates for dental implants placed and restored by students are comparable to those of experienced dentists, oral implant dentistry should be implemented as part of the undergraduate dental curriculum.

  17. 47 CFR 79.3 - Video description of video programming.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... description per calendar quarter, either during prime time or on children's programming; (2) Television... technical capability necessary to pass through the video description, unless using the technology for... video description per calendar quarter during prime time or on children's programming, on each channel...

  18. 47 CFR 79.3 - Video description of video programming.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... description per calendar quarter, either during prime time or on children's programming; (2) Television... technical capability necessary to pass through the video description, unless using the technology for... video description per calendar quarter during prime time or on children's programming, on each channel...

  19. [The Development and Application of the Orthopaedics Implants Failure Database Software Based on WEB].

    PubMed

    Huang, Jiahua; Zhou, Hai; Zhang, Binbin; Ding, Biao

    2015-09-01

    This article develops a new failure database software for orthopaedics implants based on WEB. The software is based on B/S mode, ASP dynamic web technology is used as its main development language to achieve data interactivity, Microsoft Access is used to create a database, these mature technologies make the software extend function or upgrade easily. In this article, the design and development idea of the software, the software working process and functions as well as relative technical features are presented. With this software, we can store many different types of the fault events of orthopaedics implants, the failure data can be statistically analyzed, and in the macroscopic view, it can be used to evaluate the reliability of orthopaedics implants and operations, it also can ultimately guide the doctors to improve the clinical treatment level.

  20. Totally implantable vascular access device (TIVAD) placement: a modified technique that takes post-procedure aesthetic aspects into account.

    PubMed

    Liberale, Gabriel

    2017-04-01

    Major progress has been made in breast cancer reconstruction surgery. The standard technique for totally implanted vascular access device (TIVAD) implantation generally requires an incision for port insertion on the anterior part of the thorax that leaves a scar in the middle of the neckline in patients who have undergone mastectomy with complex breast reconstruction. The aim of this technical note is to report our revised surgical technique for TIVAD placement. In patients with breast cancer, we take a lateralized approach, performing an oblique incision on the lowest part of the deltopectoral groove. This allows us to introduce the port and to place it on the anterolateral part of the thorax, thus avoiding an unaesthetic scar on the anterior part of the thorax. Our modified technique for TIVAD implantation is described.

  1. Compositional transformations in ion implanted polymers

    NASA Astrophysics Data System (ADS)

    Abdul-Kader, A. M.; Turos, A.; Grambole, D.; Jagielski, J.; Piątkowska, A.; Madi, N. K.; Al-Maadeed, M.

    2005-10-01

    Changes of surface layer composition produced by ion bombardment of polyethylene and polypropylene samples were studied. These materials are under consideration for load bearing surfaces in biological and technical applications. To improve their tribological properties, surface layers are usually modified by ionizing radiation. Therefore, to study the mechanism of transformations induced by ion beam bombardment selected polymers were implanted with H, He and Ar ions to the fluences ranging from 1 × 1013 to 2 × 1016/cm2. RBS and NRA techniques were applied for sample analysis. Important hydrogen release was observed with increasing ion dose and was correlated with the ion stopping power. Another important effect observed was the rapid oxidation of samples, which apparently occurs after exposure of implanted samples to the air. Up to 10 at.% of oxygen can be incorporated in the implanted layer.

  2. [Artificial sight: recent developments].

    PubMed

    Zeitz, O; Keserü, M; Hornig, R; Richard, G

    2009-03-01

    The implantation of electronic retina stimulators appears to be a future possibility to restore vision, at least partially in patients with retinal degeneration. The idea of such visual prostheses is not new but due to the general technical progress it has become more likely that a functioning implant will be on the market soon. Visual prosthesis may be integrated in the visual system in various places. Thus there are subretinal and epiretinal implants, as well as implants that are connected directly to the optic nerve or the visual cortex. The epiretinal approach is the most promising at the moment, but the problem of appropriate modulation of the image information is unsolved so far. This will be necessary to provide a interpretable visual information to the brain. The present article summarises the concepts and includes some latest information from recent conferences.

  3. Implantation of a cardiac resynchronization therapy-defibrillator device in a patient with persistent left superior vena cava.

    PubMed

    Atar, İlyas; Karaçağlar, Emir; Özçalık, Emre; Özin, Bülent; Müderrisoğlu, Haldun

    2015-06-01

    Presence of a persistent left superior vena cava (PLSVC) is generally clinically asymptomatic and discovered incidentally during central venous catheterization. However, PLSVC may cause technical difficulties during cardiac device implantation. An 82-year-old man with heart failure symptoms and an ejection fraction (EF) of 20% was scheduled for resynchronization therapy-defibrillator device (CRT-D) implantation. A PLSVC draining via a dilated coronary sinus into an enlarged right atrium was diagnosed. First, an active-fixation right ventricular lead was inserted into the right atrium through the PLSVC. The stylet was preshaped to facilitate its passage to the right ventricular apex. An atrial lead was positioned on the right atrium free wall, and an over-the-wire coronary sinus lead deployed to a stable position. CRT-D implantation procedure was successfully completed.

  4. REVIEW ARTICLE: Medical implants based on microsystems

    NASA Astrophysics Data System (ADS)

    Mokwa, W.

    2007-05-01

    The fast development of CMOS technologies to smaller dimensions led to very high integration densities with complex circuitry on very small chip areas. In 2006 Intel fabricated the first products in a 65 nm technology. The cointegration of microsensors or actuators together with the very low power consumption of the CMOS circuitry is very well suited for use in implanted systems. Applications like intracranial or intraocular pressure measurements have become possible. This review presents an overview over actual applications and developments of sensor/actuator-based microsystems for medical implants. It concentrates on the technical part of these investigations. It will mainly review work on systems measuring pressure in blood vessels and on systems for ophthalmic applications.

  5. Crew Transportation Technical Standards and Design Evaluation Criteria

    NASA Technical Reports Server (NTRS)

    Lueders, Kathryn L.; Thomas, Rayelle E. (Compiler)

    2015-01-01

    Crew Transportation Technical Standards and Design Evaluation Criteria contains descriptions of technical, safety, and crew health medical processes and specifications, and the criteria which will be used to evaluate the acceptability of the Commercial Providers' proposed processes and specifications.

  6. Immediate versus delayed loading of strategic mini dental implants for the stabilization of partial removable dental prostheses: a patient cluster randomized, parallel-group 3-year trial.

    PubMed

    Mundt, Torsten; Al Jaghsi, Ahmad; Schwahn, Bernd; Hilgert, Janina; Lucas, Christian; Biffar, Reiner; Schwahn, Christian; Heinemann, Friedhelm

    2016-07-30

    Acceptable short-term survival rates (>90 %) of mini-implants (diameter < 3.0 mm) are only documented for mandibular overdentures. Sound data for mini-implants as strategic abutments for a better retention of partial removable dental prosthesis (PRDP) are not available. The purpose of this study is to test the hypothesis that immediately loaded mini-implants show more bone loss and less success than strategic mini-implants with delayed loading. In this four-center (one university hospital, three dental practices in Germany), parallel-group, controlled clinical trial, which is cluster randomized on patient level, a total of 80 partially edentulous patients with unfavourable number and distribution of remaining abutment teeth in at least one jaw will receive supplementary min-implants to stabilize their PRDP. The mini-implant are either immediately loaded after implant placement (test group) or delayed after four months (control group). Follow-up of the patients will be performed for 36 months. The primary outcome is the radiographic bone level changes at implants. The secondary outcome is the implant success as a composite variable. Tertiary outcomes include clinical, subjective (quality of life, satisfaction, chewing ability) and dental or technical complications. Strategic implants under an existing PRDP are only documented for standard-diameter implants. Mini-implants could be a minimal invasive and low cost solution for this treatment modality. The trial is registered at Deutsches Register Klinischer Studien (German register of clinical trials) under DRKS-ID: DRKS00007589 ( www.germanctr.de ) on January 13(th), 2015.

  7. An angle-resolved, wavelength-dispersive x-ray fluorescence spectrometer for depth profile analysis of ion-implanted semiconductors using synchrotron radiation

    NASA Astrophysics Data System (ADS)

    Schmitt, W.; Hormes, J.; Kuetgens, U.; Gries, W. H.

    1992-01-01

    An apparatus for angle-resolved, wavelength-dispersive x-ray fluorescence spectroscopy with synchrotron radiation has been built and tested at the beam line BN2 of the Bonn electron stretcher and accelerator (ELSA). The apparatus is to be used for nondestructive depth profile analysis of ion-implanted semiconductors as part of the multinational Versailles Project of Advanced Materials and Standards (VAMAS) project on ion-implanted reference materials. In particular, the centroid depths of depth profiles of various implants is to be determined by use of the angle-resolved signal ratio technique. First results of measurements on implants of phosphorus (100 keV, 1016 cm-2) and sulfur (200 keV, 1014 cm-2) in silicon wafers using ``white'' synchrotron radiation are presented and suggest that it should be generally possible to measure the centroid depth of an implant at dose densities as low as 1014 cm-2. Some of the apparative and technical requirements are discussed which are peculiar to the use of synchrotron radiation in general and to the use of nonmonochromatized radiation in particular.

  8. Anatomy of the bovine ascending aorta and brachiocephalic artery found unfavorable for total artificial heart implant.

    PubMed

    Karimov, Jamshid H; Sunagawa, Gengo; Such, Kimberly A; Sale, Shiva; Golding, Leonard A R; Moazami, Nader; Fukamachi, Kiyotaka

    2015-12-01

    The biocompatibility assessment of the Cleveland Clinic continuous-flow total artificial heart is an important part of the device developmental program. Surgical and postoperative management are key factors in achieving optimal outcomes. However, the presence of vascular anatomical abnormalities in experimental animal models is often unpredictable and may worsen the expected outcomes. We report a technical impediment encountered during total artificial heart implantation complicated by unfavorable bovine anatomy of the ascending aorta and brachiocephalic arterial trunk.

  9. Virtual surgical planning and 3D printing in prosthetic orbital reconstruction with percutaneous implants: a technical case report

    PubMed Central

    Huang, Yu-Hui; Seelaus, Rosemary; Zhao, Linping; Patel, Pravin K; Cohen, Mimis

    2016-01-01

    Osseointegrated titanium implants to the cranial skeleton for retention of facial prostheses have proven to be a reliable replacement for adhesive systems. However, improper placement of the implants can jeopardize prosthetic outcomes, and long-term success of an implant-retained prosthesis. Three-dimensional (3D) computer imaging, virtual planning, and 3D printing have become accepted components of the preoperative planning and design phase of treatment. Computer-aided design and computer-assisted manufacture that employ cone-beam computed tomography data offer benefits to patient treatment by contributing to greater predictability and improved treatment efficiencies with more reliable outcomes in surgical and prosthetic reconstruction. 3D printing enables transfer of the virtual surgical plan to the operating room by fabrication of surgical guides. Previous studies have shown that accuracy improves considerably with guided implantation when compared to conventional template or freehand implant placement. This clinical case report demonstrates the use of a 3D technological pathway for preoperative virtual planning through prosthesis fabrication, utilizing 3D printing, for a patient with an acquired orbital defect that was restored with an implant-retained silicone orbital prosthesis. PMID:27843356

  10. Virtual surgical planning and 3D printing in prosthetic orbital reconstruction with percutaneous implants: a technical case report.

    PubMed

    Huang, Yu-Hui; Seelaus, Rosemary; Zhao, Linping; Patel, Pravin K; Cohen, Mimis

    2016-01-01

    Osseointegrated titanium implants to the cranial skeleton for retention of facial prostheses have proven to be a reliable replacement for adhesive systems. However, improper placement of the implants can jeopardize prosthetic outcomes, and long-term success of an implant-retained prosthesis. Three-dimensional (3D) computer imaging, virtual planning, and 3D printing have become accepted components of the preoperative planning and design phase of treatment. Computer-aided design and computer-assisted manufacture that employ cone-beam computed tomography data offer benefits to patient treatment by contributing to greater predictability and improved treatment efficiencies with more reliable outcomes in surgical and prosthetic reconstruction. 3D printing enables transfer of the virtual surgical plan to the operating room by fabrication of surgical guides. Previous studies have shown that accuracy improves considerably with guided implantation when compared to conventional template or freehand implant placement. This clinical case report demonstrates the use of a 3D technological pathway for preoperative virtual planning through prosthesis fabrication, utilizing 3D printing, for a patient with an acquired orbital defect that was restored with an implant-retained silicone orbital prosthesis.

  11. Hollow fiber: a biophotonic implant for live cells

    NASA Astrophysics Data System (ADS)

    Silvestre, Oscar F.; Holton, Mark D.; Summers, Huw D.; Smith, Paul J.; Errington, Rachel J.

    2009-02-01

    The technical objective of this study has been to design, build and validate biocompatible hollow fiber implants based on fluorescence with integrated biophotonics components to enable in fiber kinetic cell based assays. A human osteosarcoma in vitro cell model fiber system has been established with validation studies to determine in fiber cell growth, cell cycle analysis and organization in normal and drug treated conditions. The rationale for implant development have focused on developing benchmark concepts in standard monolayer tissue culture followed by the development of in vitro hollow fiber designs; encompassing imaging with and without integrated biophotonics. Furthermore the effect of introducing targetable biosensors into the encapsulated tumor implant such as quantum dots for informing new detection readouts and possible implant designs have been evaluated. A preliminary micro/macro imaging approach has been undertaken, that could provide a mean to track distinct morphological changes in cells growing in a 3D matrix within the fiber which affect the light scattering properties of the implant. Parallel engineering studies have showed the influence of the optical properties of the fiber polymer wall in all imaging modes. Taken all together, we show the basic foundation and the opportunities for multi-modal imaging within an in vitro implant format.

  12. RASSP Benchmark 4 Technical Description.

    DTIC Science & Technology

    1998-01-09

    be carried out. Based on results of the study, an implementation of all, or part, of the system described in this benchmark technical description...validate interface and timing constraints. The ISA level of modeling defines the limit of detail expected in the VHDL virtual prototype. It does not...develop a set of candidate architectures and perform an architecture trade-off study. Candidate proces- sor implementations must then be examined for

  13. Research Notes - An Introduction to Openness and Evolvability Assessment

    DTIC Science & Technology

    2016-08-01

    importance of different business and technical characteristics that combine to achieve an open solution. The complexity of most large-scale systems of...process characteristic)  Granularity of the architecture (size of functional blocks)  Modularity (cohesion and coupling)  Support for multiple...Description)  OV-3 (Operational Information Exchange Matrix)  SV-1 (Systems Interface Description)  TV-1 ( Technical Standards Profile). Note that there

  14. The Use of Carbon-Fiber-Reinforced (CFR) PEEK Material in Orthopedic Implants: A Systematic Review

    PubMed Central

    Li, Chuan Silvia; Vannabouathong, Christopher; Sprague, Sheila; Bhandari, Mohit

    2015-01-01

    Carbon-fiber-reinforced polyetheretherketone (CFR-PEEK) has been successfully used in orthopedic implants. The aim of this systematic review is to investigate the properties, technical data, and safety of CFR-PEEK biomaterial and to evaluate its potential for new innovation in the design of articulating medical devices. A comprehensive search in PubMed and EMBASE was conducted to identify articles relevant to the outcomes of CFR-PEEK orthopedic implants. The search was also expanded by reviewing the reference sections of selected papers and references and benchmark reports provided by content experts. A total of 23 articles were included in this review. There is limited literature available assessing the performance of CFR-PEEK, specifically as an implant material for arthroplasty systems. Nevertheless, available studies strongly support CFR-PEEK as a promising and suitable material for orthopedic implants because of its biocompatibility, material characteristics, and mechanical durability. Future studies should continue to investigate CFR-PEEK’s potential benefits. PMID:25780341

  15. The effects of hydroxyapatite coatings on stress distribution near the dental implant bone interface

    NASA Astrophysics Data System (ADS)

    Jiang, W.; Wang, W. D.; Shi, X. H.; Chen, H. Z.; Zou, W.; Guo, Z.; Luo, J. M.; Gu, Z. W.; Zhang, X. D.

    2008-11-01

    The effects of different thickness of hydroxyapatite (HA) coatings on bone stress distribution near the dental implant-bone interface are very important factors for the HA-coated dental implant design and clinical application. By means of finite element analysis (FEA), the bone stress distributions near the dental implant coated with different thicknesses from 0 to 200 μm were calculated and analyzed under the 200 N chewing load. In all cases, the maximal von Mises stresses in the bone are at the positions near the neck of dental implant on the lingual side, and decrease with the increase of the HA coatings thickness. The HA coatings weaken the stress concentration and improve the biomechanical property in the bone, however, in HA coatings thickness range of 60-120 μm, the distinctions of that benefit are not obvious. In addition, considering the technical reason of HA coatings, we conclude that thickness of HA coatings range from 60 to 120 μm would be the better choice for clinical application.

  16. Communication benefits of bilateral cochlear implantation. Retrospective study in 12-year-old children.

    PubMed

    Guerra-Jiménez, Gloria; Viera Artiles, Jaime; Mateos, Mar; González Aguado, Rocío; Falcón González, Juan Carlos; Borkoski Barreiro, Silvia; Ramos Macías, Angel

    2013-01-01

    Some studies suggest that simultaneous or sequential cochlear implantation in a short period of time offers additional benefits. There is controversy regarding the existence of an age limit after which a second implantation offers less benefit for the acquisition of communication skills. The objectives of this study were to confirm that sequential cochlear implantation offers benefits compared to unilateral implantation and to study whether, at 12 years of age, there are significant differences regarding the age at the time of the second implantation. Descriptive and observational study of a population of 12-year-old children carrying cochlear implants (n=69). A liminal pure tone audiometry and an open-field verbal discrimination test (disyllables, common phrases in an open context, with and without noise) were conducted to evaluate audiological benefits. Verbal discrimination results were better among patients who had been implanted before the age of 2 years, although the differences were not statistically significant (P>.5). Children who had received bilateral cochlear implants before the age of 2 years and with a period less than 4 years between both implants presented better verbal discrimination percentages (P<.05). In our sample, early cochlear implantation with a short period between both implants provided significant benefits regarding intelligibility. There seem to be a specific age and interimplant period, after which the auditory benefit on the first implant becomes reduced. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  17. Molecular Identification of Bacteria from Aseptically Loose Implants

    PubMed Central

    Kobayashi, Naomi; Procop, Gary W.; Krebs, Viktor; Kobayashi, Hideo

    2008-01-01

    Polymerase chain reaction (PCR) assays have been used to detect bacteria adherent to failed orthopaedic implants, but some PCR assays have had problems with probable false-positive results. We used a combination of a Staphylococcus species-specific PCR and a universal PCR followed by DNA sequencing to identify bacteria on implants retrieved from 52 patients (92 implants) at revision arthroplasty. We addressed two questions in this study: (1) Is this method able to show the existence of bacterial DNA on presumed aseptic loosed implants?; and (2) What proportion of presumed aseptic or culture-negative implants was positive for bacterial DNA by PCR? Fourteen implants (15%) were believed infected, whereas 74 implants (85%) were believed aseptic. Each implant was sonicated and the resulting solution was submitted for dual real-time PCR assay and culture. All implants believed aseptically loose were culture-negative, but nine of the 74 (12%) had bacterial DNA by PCR; two (2.7%) were PCR-positive and also showed histologic findings suggestive of infection. Uniquely developed PCR and bacterial sequencing assays showed bacterial DNA on 12% of implants removed for presumed aseptic loosening. Additional studies are needed to determine the clinical importance of bacterial DNA detected by PCR but not by conventional culture. Level of Evidence: Level III, diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18438724

  18. 30 CFR 777.13 - Reporting of technical data.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... descriptions of the methodology used to collect and analyze the data. (b) Technical analyses shall be planned... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Reporting of technical data. 777.13 Section 777... PROGRAMS GENERAL CONTENT REQUIREMENTS FOR PERMIT APPLICATIONS § 777.13 Reporting of technical data. (a) All...

  19. 76 FR 16785 - Meeting for Software Developers on the Technical Specifications for Common Formats for Patient...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-25

    ... Software Developers on the Technical Specifications for Common Formats for Patient Safety Data Collection... designed as an interactive forum where PSOs and software developers can provide input on these technical... updated event descriptions, forms, and technical specifications for software developers. As an update to...

  20. A Case Study of Technical Assistance to Demonstration Programs for Young Handicapped Children. Part I.

    ERIC Educational Resources Information Center

    Behr, Shirley K.; And Others

    The interim report presents an evaluation of TADS (Technical Assistance Development System) through case studies of TADS technical assistance to the staffs of two demonstration programs for preschool handicapped children and their families. Purposes of the study included obtaining indepth descriptions of the technical assistance process to…

  1. Technical nuances to minimize common complications of deep brain stimulation.

    PubMed

    House, Paul

    2017-04-01

    The implantation of deep brain stimulator electrodes is associated with infrequent complications. These complications are consistent across prospective trials and include infection, skin erosion, hemorrhage, and lead misplacement. Nuances of surgical technique can be used to minimize the risk of these commonly noted complications. Several of these technical nuances are highlighted in this video submission. The video can be found here: https://youtu.be/GL09W9p013g .

  2. Impact of Different Surgeons on Dental Implant Failure.

    PubMed

    Chrcanovic, Bruno Ramos; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    To assess the influence of several factors on the prevalence of dental implant failure, with special consideration of the placement of implants by different dental surgeons. This retrospective study is based on 2,670 patients who received 10,096 implants at one specialist clinic. Only the data of patients and implants treated by surgeons who had inserted a minimum of 200 implants at the clinic were included. Kaplan-Meier curves were stratified with respect to the individual surgeon. A generalized estimating equation (GEE) method was used to account for the fact that repeated observations (several implants) were placed in a single patient. The factors bone quantity, bone quality, implant location, implant surface, and implant system were analyzed with descriptive statistics separately for each individual surgeon. A total of 10 surgeons were eligible. The differences between the survival curves of each individual were statistically significant. The multivariate GEE model showed the following variables to be statistically significant: surgeon, bruxism, intake of antidepressants, location, implant length, and implant system. The surgeon with the highest absolute number of failures was also the one who inserted the most implants in sites of poor bone and used turned implants in most cases, whereas the surgeon with the lowest absolute number of failures used mainly modern implants. Separate survival analyses of turned and modern implants stratified for the individual surgeon showed statistically significant differences in cumulative survival. Different levels of failure incidence could be observed between the surgeons, occasionally reaching significant levels. Although a direct causal relationship could not be ascertained, the results of the present study suggest that the surgeons' technique, skills, and/or judgment may negatively influence implant survival rates.

  3. Earfold Implantable Clip System for Correction of Prominent Ears: Analysis of Safety in 403 Patients

    PubMed Central

    Sojitra, Nilesh; Glumicic, Sinisa; Vlok, Jacobus A.; O’Toole, Greg; Hannan, S. Alam; Sabbagh, Walid

    2018-01-01

    Background: The Earfold system, a new treatment for the correction of prominent ears, consists of 3 components: the Earfold implant, the Earfold introducer, and the Prefold positioner. Methods: This is an interim report based on an ongoing analysis of safety in a series of patients treated for prominent ears with the Earfold implant between February 2013 and September 2014. Safety was assessed based on adverse event reports and the need for implant revision; follow-up is ongoing. Results: Seven surgeons used 1,200 Earfold implants to treat 403 patients (ages, 7–70 years; 63% male); the time since the initial implant procedure now ranges from 30 to 48 months. To date, 145 patients (36%) have returned for a follow-up visit (mean, 7.7 months [range, 1–34 months]). Adverse events requiring intervention have affected 39 of 403 (9.7%) patients; these include implant revisions (n = 17 [4.2%], most often due to implant visibility), skin erosion over the implant (n = 15 [3.7%]), and infection (n = 7 [1.7%]). Bleeding, recurrence of prominence, hematoma, deformity, or adverse scarring did not occur. Conclusions: This interim analysis has shown that Earfold prominent ear correction system is associated with relatively few adverse events that require intervention; a small number of patients experienced infection, implant extrusion, or implant visibility that required revision. Most adverse events were related to either patient selection or technical errors at implantation. It is expected that with continued use of Earfold by surgeons experienced in otoplasty, the adverse event incidence will decrease. PMID:29464160

  4. Coated and uncoated self-expanding metal stents for malignant stenosis in the upper GI tract: preliminary clinical experiences with Wallstents.

    PubMed

    Ell, C; Hochberger, J; May, A; Fleig, W E; Hahn, E G

    1994-09-01

    The clinical feasibility of self-expanding metal stents with respect to the technical success, complications, and reintervention rate should be tested. Five coated and 26 uncoated prototype Wallstents, especially designed for stenosis of the upper GI tract, were implanted in 23 patients. All patients with dysphagia suffered from inoperable tumor stenosis of the esophagus or the cardia. Stent implantation was performed under slight i.v. sedoanalgesia. Technical success was achieved in all 31 implanted stents. Forty-eight hr after implantation, dysphagia was improved in 21/23 patients. Acute problems observed within 1 wk were stent migration (1 patient, uncoated stent), oblique position of the stent (3 patients), epigastric or retrosternal pain (9 patients), insufficient stent expansion (4 patients), and pouch formation at the upper rim of the stent (4 patients). An uncomplicated follow-up (median 66 days, range 10-139 days) was seen in 12 patients (52%). Major problems in the follow-up period were stent migration in three patients (three coated stents, two stent migrations in one patient) and stent obstruction by tumor ingrowth/overgrowth and/or food impaction in eight patients (35%). Most of these problems could be successfully resolved by implantation of a second stent or electrocoagulation of overgrowing tumor tissue. By the 1st of March, 1994, three patients were still alive with a follow-up period of 530 days (median range, 336-880 days); 20 patients were decreased with a follow-up period of 70 days (median range, 3-374 days). Implantation of esophageal Wallstents is safe and has a low risk of acute complications and mortality for the patient. Early complications such as perforation and bleeding did not occur. Tumor ingrowth/overgrowth are the major reasons for the high reintervention rate in the follow-up period. Coated stents can resolve this problem, provided that stent migration can be avoided by improvement of the coating technology.

  5. The "neuro-mapping locator" software. A real-time intraoperative objective paraesthesia mapping tool to evaluate paraesthesia coverage of the painful zone in patients undergoing spinal cord stimulation lead implantation.

    PubMed

    Guetarni, F; Rigoard, P

    2015-03-01

    Conventional spinal cord stimulation (SCS) generates paraesthesia, as the efficacy of this technique is based on the relationship between the paraesthesia provided by SCS on the painful zone and an analgesic effect on the stimulated zone. Although this basic postulate is based on clinical evidence, it is clear that this relationship has never been formally demonstrated by scientific studies. There is a need for objective evaluation tools ("transducers") to transpose electrical signals to clinical effects and to guide therapeutic choices. We have developed a software at Poitiers University hospital allowing real-time objective mapping of the paraesthesia generated by SCS lead placement and programming during the implantation procedure itself, on a touch screen interface. The purpose of this article is to describe this intraoperative mapping software, in terms of its concept and technical aspects. The Neuro-Mapping Locator (NML) software is dedicated to patients with failed back surgery syndrome, candidates for SCS lead implantation, to actively participate in the implantation procedure. Real-time geographical localization of the paraesthesia generated by percutaneous or multicolumn surgical SCS lead implanted under awake anaesthesia allows intraoperative lead programming and possibly lead positioning to be modified with the patient's cooperation. Software updates should enable us to refine objectives related to the use of this tool and minimize observational biases. The ultimate goals of NML software should not be limited to optimize one specific device implantation in a patient but also allow to compare instantaneously various stimulation strategies, by characterizing new technical parameters as "coverage efficacy" and "device specificity" on selected subgroups of patients. Another longer-term objective would be to organize these predictive factors into computer science ontologies, which could constitute robust and helpful data for device selection and programming of tomorrow's neurostimulators. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  6. Do "premium" joint implants add value?: analysis of high cost joint implants in a community registry.

    PubMed

    Gioe, Terence J; Sharma, Amit; Tatman, Penny; Mehle, Susan

    2011-01-01

    Numerous joint implant options of varying cost are available to the surgeon, but it is unclear whether more costly implants add value in terms of function or longevity. We evaluated registry survival of higher-cost "premium" knee and hip components compared to lower-priced standard components. Premium TKA components were defined as mobile-bearing designs, high-flexion designs, oxidized-zirconium designs, those including moderately crosslinked polyethylene inserts, or some combination. Premium THAs included ceramic-on-ceramic, metal-on-metal, and ceramic-on-highly crosslinked polyethylene designs. We compared 3462 standard TKAs to 2806 premium TKAs and 868 standard THAs to 1311 premium THAs using standard statistical methods. The cost of the premium implants was on average approximately $1000 higher than the standard implants. There was no difference in the cumulative revision rate at 7-8 years between premium and standard TKAs or THAs. In this time frame, premium implants did not demonstrate better survival than standard implants. Revision indications for TKA did not differ, and infection and instability remained contributors. Longer followup is necessary to demonstrate whether premium implants add value in younger patient groups. Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  7. Guideline on cochlear implants.

    PubMed

    Manrique, Manuel; Ramos, Ángel; de Paula Vernetta, Carlos; Gil-Carcedo, Elisa; Lassaleta, Luis; Sanchez-Cuadrado, Isabel; Espinosa, Juan Manuel; Batuecas, Ángel; Cenjor, Carlos; Lavilla, María José; Núñez, Faustino; Cavalle, Laura; Huarte, Alicia

    2018-03-26

    In the last decade numerous hospitals have started to work with patients who are candidates for a cochlear implant (CI) and there have been numerous and relevant advances in the treatment of sensorineural hearing loss that extended the indications for cochlear implants. To provide a guideline on cochlear implants to specialists in otorhinolaryngology, other medical specialities, health authorities and society in general. The Scientific Committees of Otology, Otoneurology and Audiology from the Spanish Society of Otolaryngology and Head and Neck Surgery (SEORL-CCC), in a coordinated and agreed way, performed a review of the current state of CI based on the existing regulations and in the scientific publications referenced in the bibliography of the document drafted. The clinical guideline on cochlear implants provides information on: a) Definition and description of Cochlear Implant; b) Indications for cochlear implants; c) Organizational requirements for a cochlear implant programme. A clinical guideline on cochlear implants has been developed by a Committee of Experts of the SEORL-CCC, to help and guide all the health professionals involved in this field of CI in decision-making to treathearing impairment. Copyright © 2018 Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Performance/Design Requirements and Detailed Technical Description for a Computer-Directed Training Subsystem for Integration into the Air Force Phase II Base Level System.

    ERIC Educational Resources Information Center

    Butler, A. K.; And Others

    The performance/design requirements and a detailed technical description for a Computer-Directed Training Subsystem to be integrated into the Air Force Phase II Base Level System are described. The subsystem may be used for computer-assisted lesson construction and has presentation capability for on-the-job training for data automation, staff, and…

  9. [Latissimus dorsi myocutaneous flap combined with implant in breast reconstruction: The technique of the dorsal bra].

    PubMed

    Bruant-Rodier, C; Chiriac, S; Baratte, A; Dissaux, C; Bodin, F

    2016-06-01

    The latissimus dorsi myocutaneous flap combined with an implant is an effective breast reconstruction solution especially in irradiated patients. The authors describe the specific technical aspects that allow them to optimize the results of this intervention. In the back, the skin paddle is drawn in the shape of a horizontal spindle so as to conceal the residual scar under the bra. In breast area, a J-shaped contraincision barring the mastectomy scar ensures a harmonious positioning of the skin paddle to the inferolateral part of the breast. After a 180° rotation, the latissimus dorsi muscle envelops the implant like a bra. Its upper edge is attached at the bottom to define the new submammary fold. Under the pectoralis major muscle, its distal end comes to fill the décolleté above the implant. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  10. EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability

    PubMed Central

    Chan, Jessica E; Netland, Peter A

    2015-01-01

    Trabeculectomy has been the traditional primary surgical therapy for open-angle glaucoma. While trabeculectomy is effective in lowering intraocular pressure, complications associated with the procedure have motivated the development of alternative techniques and devices, including the EX-PRESS Glaucoma Filtration Device. This review describes the efficacy, safety, complication rates, and potential advantages and disadvantages of the EX-PRESS Glaucoma Filtration Device. EX-PRESS implantation is technically simpler compared with that of trabeculectomy, with fewer surgical steps. Vision recovery has been more rapid after EX-PRESS implantation compared with trabeculectomy. Intraocular pressure variation is lower during the early postoperative period, indicating a more predictable procedure. While efficacy of the EX-PRESS implant has been comparable to trabeculectomy, postoperative complications appear less common after EX-PRESS implantation compared with trabeculectomy. The EX-PRESS Glaucoma Filtration Device appears to be safe and effective in the surgical management of open-angle glaucoma. PMID:26366105

  11. Bruxism and dental implant failures: a multilevel mixed effects parametric survival analysis approach.

    PubMed

    Chrcanovic, B R; Kisch, J; Albrektsson, T; Wennerberg, A

    2016-11-01

    Recent studies have suggested that the insertion of dental implants in patients being diagnosed with bruxism negatively affected the implant failure rates. The aim of the present study was to investigate the association between the bruxism and the risk of dental implant failure. This retrospective study is based on 2670 patients who received 10 096 implants at one specialist clinic. Implant- and patient-related data were collected. Descriptive statistics were used to describe the patients and implants. Multilevel mixed effects parametric survival analysis was used to test the association between bruxism and risk of implant failure adjusting for several potential confounders. Criteria from a recent international consensus (Lobbezoo et al., J Oral Rehabil, 40, 2013, 2) and from the International Classification of Sleep Disorders (International classification of sleep disorders, revised: diagnostic and coding manual, American Academy of Sleep Medicine, Chicago, 2014) were used to define and diagnose the condition. The number of implants with information available for all variables totalled 3549, placed in 994 patients, with 179 implants reported as failures. The implant failure rates were 13·0% (24/185) for bruxers and 4·6% (155/3364) for non-bruxers (P < 0·001). The statistical model showed that bruxism was a statistically significantly risk factor to implant failure (HR 3·396; 95% CI 1·314, 8·777; P = 0·012), as well as implant length, implant diameter, implant surface, bone quantity D in relation to quantity A, bone quality 4 in relation to quality 1 (Lekholm and Zarb classification), smoking and the intake of proton pump inhibitors. It is suggested that the bruxism may be associated with an increased risk of dental implant failure. © 2016 John Wiley & Sons Ltd.

  12. Long-term outcomes of oral rehabilitation with dental implants in HIV-positive patients: A retrospective case series

    PubMed Central

    Gay-Escoda, Cosme; Pérez-Álvarez, Débora; Camps-Font, Octavi

    2016-01-01

    Background The existing information on oral rehabilitations with dental implants in VIH-positive patients is scarce and of poor quality. Moreover, no long-term follow-up studies are available. Hence, the aims of this study were to describe the long-term survival and success rates of dental implants in a group of HIV-positive patients and to identify the most common postoperative complications, including peri-implant diseases. Material and Methods A retrospective case series of HIV-positive subjects treated with dental implants at the School of Dentistry of the University of Barcelona (Spain) was studied. Several clinical parameters were registered, including CD4 cell count, viral load and surgical complications. Additionally, the patients were assessed for implant survival and success rates and for the prevalence of peri-implant diseases. A descriptive statistical analysis of the data was performed. Results Nine participants (57 implants) were included. The patients’ median age was 42 years (IQR=13.5 years). The implant survival and success rates were 98.3% and 68.4%, respectively, with a mean follow-up of 77.5 months (SD=16.1 months). The patient-based prevalence of peri-implant mucositis and peri-implantitis were 22.2% and 44.4% respectively at the last appointment. Patients that attended regular periodontal maintenance visits had significantly less mean bone loss than non-compliant patients (1.3 mm and 3.9 mm respectively). Conclusions Oral rehabilitation with dental implants in HIV-positive patients seems to provide satisfactory results. In order to reduce the considerably high prevalence of peri-implant diseases, strict maintenance programmes must be implemented. Key words:HIV infection, dental implants, oral implantology, complications, peri-implantitis, peri-implant diseases. PMID:26946205

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vajda, Zsolt, E-mail: Z.Vajda@klinikum-stuttgart.de; Guethe, Thomas, E-mail: T.Guethe@klinikum-stuttgart.de; Perez, Marta Aguilar, E-mail: M.Aguilar@klinikum-stuttgart.de

    Stenting in intracranial atherosclerotic disease (ICAD) is increasingly debated, due to issues of procedural safety, technical efficacy, and in-stent recurrent stenoses (ISR). In the present study, feasibility, safety, and efficacy of angioplasty using a drug-eluting balloon (DEB) followed by the implantation of a self-expanding stent (Enterprise) were evaluated for the treatment of ICAD lesions. Fifty-two patients (median age: 71 years; range: 54-86 years; male/female ratio 37:15) underwent stenting of high-grade ICAD lesions between February 2010 and November 2011 in a single center. Angioplasty using a paclitaxel coated SeQuent Please (B. Braun, Germany) or DIOR (Eurocor, Germany) coronary PTCA balloon, followedmore » by the implantation of a self-expanding stent (Enterprise, Codman, USA) was performed in 54 lesions. Angiographic and clinical follow-up was performed at 6 and 12 weeks, 6 and 12 months, and yearly thereafter. Technical success rate, periprocedural complications, occurrence of recurrent ischemic symptoms, and the development of an ISR were analyzed. Angioplasty using a DEB followed by stent implantation was successfully performed in 44 (81 %) cases. DEB insertion failed in 19 % of the cases and angioplasty was finally performed using a conventional PTCA balloon. The combined procedure related permanent neurologic morbidity and mortality rate (stroke, ICH, and subarachnoid hemorrhage) at 30 days and beyond was 5 %. Angiographic and clinical follow-up were obtained in 33 (61 %) lesions in 32 patients. Recurrent stenosis was seen in one (3 %) lesion. Angioplasty and stenting using a DEB is safe and yields encouragingly low ISR rates. Further technical developments to improve lesion accessibility are, nevertheless, mandatory.« less

  14. [Early results with a monorail-stent-balloon device for endovascular treatment of renal artery stenosis].

    PubMed

    Müller-Hülsbeck, S; Jahnke, T; Grimm, J; Behm, C; Hilbert, C; Frahm, C; Biederer, J; Brossmann, J; Heller, M

    2002-03-01

    To evaluate the technical feasibility of a new monorail-stent-balloon device for treatment of renal artery stenosis (RAS). During a study period of 18 months, 38 patients with proven RAS in 41 cases (hypertension n = 36, renal insufficiency n = 13) and indication for stenting (calicified ostial lesions n = 35, insufficient PTA n = 4, dissection n = 2) were enrolled into this prospective evaluation. Pre-mounted stents (Rx-Herculink(TM) 5 mm = 13, 6 mm = 34, 7 mm = 1) were implanted a transfemoral (n = 35) or transbrachial approach (n = 6). Mean grade and lengths of stenosis measured were 88 % plus minus 10 and 9 mm plus minus 5. Renal stent implantation was technically successful in all cases (100 %). In 7 cases a second stent had to be implanted to cover the entire lesion. The transstenotic pressure drop decreased from 88 mmHg plus minus 10 before to 1 mmHg plus minus 1.8 after the procedure. Remaining stenosis measured 0.7 % plus minus 4.2. Serum creatine levels decreased from 1.9 mm/dl to 1.5 mg/dl (n. s.), blood pressure decreased from 178/94 mmHg to 148/79 mmHg (p < 0.0001) after the intervention. Primary and secondary patency rates at 6 months were 72 % (Standard Error 9.8 %) and 77 (% (Standard Error 9.2 %), respectively. With the used monorail-stend-balloon device a technically easy, secure and exact renal stent placement is guaranteed, patency rates are similar to those described in the current literature.

  15. Treatment Approach for Infection of Healed Fractures After Internal Fixation.

    PubMed

    Lawrenz, Joshua M; Frangiamore, Salvatore J; Rane, Ajinkya A; Cantrell, William Alex; Vallier, Heather A

    2017-11-01

    To review the efficacy of a treatment approach for patients with infection and colonized implants after open reduction and internal fixation of fractures. Retrospective case series. Level one trauma center. Twenty patients were treated for wound infection with colonized implants after open reduction and internal fixation. Surgical debridement, removal of implants, and a short postoperative oral antibiotic course. The course of patients after surgical debridement and removal of implants, including culture results, antibiotic administration, and presence of recurrent clinical infection and radiographic union. Twenty patients had clinical presentations, including skin breakdown, serous drainage, purulent drainage and/or exposed implants, most commonly of the tibia (15 of 20). Mean time from index procedure to debridement with implant removal was 19.7 months. At the time of debridement and implant removal, 18 of 20 (90%) patients had a positive intraoperative culture (16 routine cultures and 2 broth cultures). The most common bacteria were Enterobacter cloacae (5/17) and methicillin-sensitive Staphylococcus aureus (4/17). All patients had soft tissue healing without signs of recurrent infection after mean follow up of 40 months after implant removal. Surgical debridement with implant removal plus a short oral antibiotic course is effective to resolve wound infection with a colonized implant in the setting of healed fracture after internal fixation. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  16. STARLAB UV-optical telescope facility, volume 1

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The STARLAB accomplishments to date include both the feasibility definition and detailed design study efforts on critical subsystems. Topics of discussion for this report include: (1) STARLAB capabilities; (2) scientific programs; (3) STARLAB technical description; (4) STARLAB Phase B studies; and (5) technical conclusions Technical recommendations.

  17. A comparison of two implant techniques on patient-based outcome measures: a report of flapless vs. conventional flapped implant placement.

    PubMed

    Lindeboom, Jerome A; van Wijk, Arjen J

    2010-04-01

    Flapless implant surgery is considered to offer advantages over the traditional flap access approach. There may be minimized bleeding, decreased surgical times and minimal patient discomfort. Controlled studies comparing patient outcome variables to support these assumptions, however, are lacking. The objective of this clinical study was to compare patient outcome variables using flapless and flapped implant surgical techniques. From January 2008 to October 2008, 16 consecutive patients with edentulous maxillas were included in the study. Patients were randomly allocated to either implant placement with a flapless procedure (eight patients, mean age 54.6 + or - 2.9 years) or surgery with a conventional flap procedure (eight patients, mean age 58.7 + or - 7.2 years). All implants were placed using a Nobel guide CT-guided surgical template. Outcome measures were the Dutch version of the Impact of Event Scale-Revised (IES-R), dental anxiety using the s-DAI and oral health-related quality of life (OHIP-14). Ninety-six implants were successfully placed. All implants were placed as two-phase implants and the after-implant placement dentures were adapted. No differences could be shown between conditions on dental anxiety (s-DAI), emotional impact (IES-R), anxiety, procedure duration or technical difficulty, although the flapless group did score consistently higher. The flap procedure group reported less impact on quality of life and included more patients who reported feeling no pain at all during placement. Differences found in the patient outcome variables do suggest that patients in the flapless implant group had to endure more than patients in the flap group.

  18. Does the presence of antagonist remaining teeth affect implant overdenture success? A systematic review.

    PubMed

    Ohkubo, C; Baek, K W

    2010-04-01

    Many patients who need implant overdentures are not completely edentulous; they still have antagonist natural teeth or implant fixed prostheses. In such cases, however, little is known about whether existing natural teeth affect the success of implant overdentures positively or act as a complicating factor. This systematic review attempts to clarify the correlation between existing remaining teeth and the survival/success rate of maxillary and mandibular implant overdentures. An assessment of available relevant articles published in English from 1990 to 2009 was performed using an online database and a manual search in libraries. Although the opposing natural dentition was not sufficiently described in the literature, 10 articles about the mandible and 10 articles about the maxilla were selected. As there was no controlled study on the natural teeth opposing implant overdentures, this review could not reach a clear conclusion. The review did reveal a remarkably high success/survival rate for mandibular implant overdentures; maxillary implant overdentures showed a lower rate. The presence of antagonist teeth hardly seems to be a risk factor for success for mandibular implant overdentures. For maxillary implant overdentures, the existence of antagonist teeth might act negatively for implant survival, but they are certainly not a contraindication. Although a few articles stated this relationship, we could not find an apparent correlation between the remaining antagonist teeth and the success of the implant overdentures. A detailed description of the opposing dentate status and results of randomized controlled clinical trials would be required to characterize this evidence-based implant overdenture treatment.

  19. Long-term outcomes of oral rehabilitation with dental implants in HIV-positive patients: A retrospective case series.

    PubMed

    Gay-Escoda, C; Pérez-Álvarez, D; Camps-Font, O; Figueiredo, R

    2016-05-01

    The existing information on oral rehabilitations with dental implants in VIH-positive patients is scarce and of poor quality. Moreover, no long-term follow-up studies are available. Hence, the aims of this study were to describe the long-term survival and success rates of dental implants in a group of HIV-positive patients and to identify the most common postoperative complications, including peri-implant diseases. A retrospective case series of HIV-positive subjects treated with dental implants at the School of Dentistry of the University of Barcelona (Spain) was studied. Several clinical parameters were registered, including CD4 cell count, viral load and surgical complications. Additionally, the patients were assessed for implant survival and success rates and for the prevalence of peri-implant diseases. A descriptive statistical analysis of the data was performed. Nine participants (57 implants) were included. The patients' median age was 42 years (IQR=13.5 years). The implant survival and success rates were 98.3% and 68.4%, respectively, with a mean follow-up of 77.5 months (SD=16.1 months). The patient-based prevalence of peri-implant mucositis and peri-implantitis were 22.2% and 44.4% respectively at the last appointment. Patients that attended regular periodontal maintenance visits had significantly less mean bone loss than non-compliant patients (1.3 mm and 3.9 mm respectively). Oral rehabilitation with dental implants in HIV-positive patients seems to provide satisfactory results. In order to reduce the considerably high prevalence of peri-implant diseases, strict maintenance programmes must be implemented.

  20. An investigation of wing buffeting response at subsonic and transonic speeds: Phase 1: F-111A flight data analysis. Volume 1: Summary of technical approach, results and conclusions

    NASA Technical Reports Server (NTRS)

    Benepe, D. B.; Cunningham, A. M., Jr.; Dunmyer, W. D.

    1978-01-01

    The structural response to aerodynamic buffet during moderate to high-g maneuvers at subsonic and transonic speeds was investigated. The investigation is reported in three volumes. This volume presents a summary of the investigation with a complete description of the technical approach, description of the aircraft, its instrumentation, the data reduction procedures, results and conclusion.

  1. 48 CFR 14.201-6 - Solicitation provisions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...-21, Descriptive Literature, in invitations for bids if (i) descriptive literature is required to evaluate the technical acceptability of an offered product and (ii) the required information will not be... possibility exists that the contracting officer may waive the requirement for furnishing descriptive...

  2. 48 CFR 14.201-6 - Solicitation provisions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...-21, Descriptive Literature, in invitations for bids if (i) descriptive literature is required to evaluate the technical acceptability of an offered product and (ii) the required information will not be... possibility exists that the contracting officer may waive the requirement for furnishing descriptive...

  3. 48 CFR 14.201-6 - Solicitation provisions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...-21, Descriptive Literature, in invitations for bids if (i) descriptive literature is required to evaluate the technical acceptability of an offered product and (ii) the required information will not be... possibility exists that the contracting officer may waive the requirement for furnishing descriptive...

  4. 48 CFR 14.201-6 - Solicitation provisions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-21, Descriptive Literature, in invitations for bids if (i) descriptive literature is required to evaluate the technical acceptability of an offered product and (ii) the required information will not be... possibility exists that the contracting officer may waive the requirement for furnishing descriptive...

  5. 48 CFR 14.201-6 - Solicitation provisions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...-21, Descriptive Literature, in invitations for bids if (i) descriptive literature is required to evaluate the technical acceptability of an offered product and (ii) the required information will not be... possibility exists that the contracting officer may waive the requirement for furnishing descriptive...

  6. Characterization of Cement Particles Found in Peri-implantitis-Affected Human Biopsy Specimens.

    PubMed

    Burbano, Maria; Wilson, Thomas G; Valderrama, Pilar; Blansett, Jonathan; Wadhwani, Chandur P K; Choudhary, Pankaj K; Rodriguez, Lucas C; Rodrigues, Danieli C

    2015-01-01

    Peri-implantitis is a disease characterized by soft tissue inflammation and continued loss of supporting bone, which can result in implant failure. Peri-implantitis is a multifactorial disease, and one of its triggering factors may be the presence of excess cement in the soft tissues surrounding an implant. This descriptive study evaluated the composition of foreign particles from 36 human biopsy specimens with 19 specimens selected for analysis. The biopsy specimens were obtained from soft tissues affected by peri-implantitis around cement-retained implant crowns and compared with the elemental composition of commercial luting cement. Nineteen biopsy specimens were chosen for the comparison, and five test cements (TempBond, Telio, Premier Implant Cement, Intermediate Restorative Material, and Relyx) were analyzed using scanning electron microscopy equipped with energy dispersive x-ray spectroscopy. This enabled the identification of the chemical composition of foreign particles embedded in the tissue specimens and the composition of the five cements. Statistical analysis was conducted using classification trees to pair the particles present in each specimen with the known cements. The particles in each biopsy specimen could be associated with one of the commercial cements with a level of probability ranging between .79 and 1. TempBond particles were found in one biopsy specimen, Telio particles in seven, Premier Implant Cement particles in four, Relyx particles in four, and Intermediate Restorative Material particles in three. Particles found in human soft tissue biopsy specimens around implants affected by peri-implant disease were associated with five commercially available dental cements.

  7. Astronomical Book Trek: Astronomy Books of 1983.

    ERIC Educational Resources Information Center

    Fraknoi, Andrew

    1984-01-01

    Presents an annotated list of technical and non-technical astronomy books. Topic areas of non-technical books include general astronomy, amateur astronomy, computers and astronomy, history of astronomy, pseudoscience, space exploration, physics and astronomy, and textbooks. Each entry includes author, title, description, source, and current cost.…

  8. [Postoperative Follow-Up of Glaucoma Drainage Devices].

    PubMed

    Dietlein, T S; Neugebauer, A; Fricke, J; Lappas, A; Rosentreter, A

    2016-05-01

    There is an increasing trend towards using glaucoma drainage implants. The postoperative management of such devices depends on their technical characteristics and specific complications. The Baerveldt glaucoma implant with its larger surface area has been shown to lower mean intraocular pressure more effectively than the Ahmed-FP7 implant. As a non-valve implant, however, it has been associated with a higher rate of severe complications, particularly ocular hypotension. Moreover, glaucoma implants may induce diplopia if they interfere with extraocular muscles. Topical treatment with antibiotics and steroids is necessary in cases of intraocular inflammation. In refractory cases, the tube may even have to be removed. Surgical reposition of the tube may be indicated when it is severely dislocated. Increased intraocular pressure is primarily treated by pressure-lowering medications during postoperative follow-up. If topical glaucoma medication is insufficient to control increases in intraocular pressure due to encapsulation, a second implant may be considered or the capsule surrounding the implant may be excised to reduce outflow resistance or additional cyclodestructive procedures can be performed. Chronic hypotension may be treated with tube ligation or occlusion. Severe corneal oedema may require lamellar keratoplasty. Conjunctival erosions with tube exposure or tube retractions also require surgical correction. Georg Thieme Verlag KG Stuttgart · New York.

  9. Cochlear Implants and Psychiatric Assessments: a Norrie Disease Case Report.

    PubMed

    Jacques, Denis; Dubois, Thomas; Zdanowicz, Nicolas; Gilain, Chantal; Garin, Pierre

    2017-09-01

    It is important to perform psychiatric assessments of adult patients who are candidates for cochlear implants both to screen them for psychiatric disorders and to assess their understanding and compliance with the procedure. Deafness is a factor of difficulty for conducting in-depth psychiatric interviews, but concomitant blindness may make it impossible. After a description of Norrie disease, a rare disease in which blindness and deafness may occur together, we propose a case report of a patient suffering from the disease and who consulted in view of a cochlear implant. Early information on cochlear implants appears to be necessary before total deafness occurs in patients suffering from Norrie disease. An inventory of digital communication tools that can be used by the patient is also highly valuable. Research should be supported for a more systematic use of psychiatric assessments prior to cochlear implants. In the special case of Norrie disease, we recommend early screening for mental retardation and related psychotic disorders and, depending on the patient's level of understanding, preventive information on the benefits and limits of cochlear implants before total deafness occurs.

  10. [What can we learn in future from the data of the German Arthroplasty Registry (EPRD) in comparison to other registries?].

    PubMed

    Jansson, V; Steinbrück, A; Hassenpflug, J

    2016-06-01

    The German Arthroplasty Registry (EPRD) was founded in 2010 and has been in full operation since 2014. Previous attempts at a systematic data collection of elective and non-elective knee and hip replacement in Germany failed mainly because of the long-term lack of funding. The EPRD is an interdisciplinary collaborative partnership between the German Association of Orthopedics and Orthopedic Surgery (DGOOC), all implant manufacturers of the German Medical Technology Association (BVMed), health insurers (AOK and the Association of Additional Healthcare Insurance) and hospitals (German Hospital Federation). As part of this cooperation a worldwide unique implant database has been set up, which includes all relevant components and a detailed description of implant specifications. This implant library enables a detailed evaluation of implant survival, revision rates and possible inferior implant performance of knee and hip replacements in Germany. At the end of 2015 the EPRD encompassed over 200,000 registered operations. Due to the high number of hip and knee arthroplasties in Germany with many different implants from different manufacturers there will be a rapid growth of data that are available for a national and also international comparison of the results.

  11. Adaptation of cardiovascular system stent implants.

    PubMed

    Ostasevicius, Vytautas; Tretsyakou-Savich, Yahor; Venslauskas, Mantas; Bertasiene, Agne; Minchenya, Vladimir; Chernoglaz, Pavel

    2018-06-27

    Time-consuming design and manufacturing processes are a serious disadvantage when adapting human cardiovascular implants as they cause unacceptable delays after the decision to intervene surgically has been made. An ideal cardiovascular implant should have a broad range of characteristics such as strength, viscoelasticity and blood compatibility. The present research proposes the sequence of the geometrical adaptation procedures and presents their results. The adaptation starts from the identification of a person's current health status while performing abdominal aortic aneurysm (AAA) imaging, which is a point of departure for the mathematical model of a cardiovascular implant. The computerized tomography scan shows the patient-specific geometry parameters of AAA and helps to create a model using COMSOL Multiphysics software. The initial parameters for flow simulation are taken from the results of a patient survey. The simulation results allow choosing the available shape of an implant which ensures a non-turbulent flow. These parameters are essential for the design and manufacturing of an implant prototype which should be tested experimentally for the assurance that the mathematical model is adequate to a physical one. The article gives a focused description of competences and means that are necessary to achieve the shortest possible preparation of the adapted cardiovascular implant for the surgery.

  12. Mitral valve repair with adjustable ring annuloplasty.

    PubMed

    Andreas, Martin; Haberl, Thomas; Paul Werner, Paul Werner; Guri, Jani; Kocher, Alfred; Hamza, Ouafa; Podesser, Bruno; Laufer, Guenther

    2018-02-28

    We demonstrate the technical aspects of a novel adjustable mitral ring. This new ring was implanted in a female landrace pig, for training and educational purposes. It can be adjusted independently in the P1, P2 and P3 segments, if required, to treat  recurrent mitral regurgitation, and this is a key difference to comparable devices. The first-in-man implantation is anticipated in the near future. © The Author 2016. Published by MMCTS on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  13. Technical report: precisely fitting bars on implants in five steps-a CAD/CAM concept for the edentulous mandible.

    PubMed

    Beuer, Florian; Schweiger, Josef; Huber, Martin; Engels, Jörg; Stimmelmayr, Michael

    2014-06-01

    Various treatment concepts have been presented for the edentulous mandible. Manufacturing tension-free and precisely fitting bars on dental implants was previously a great challenge in prosthetic dentistry and required great effort. Modern computer aided design/computer aided manufacturing technology in combination with some clinical modifications of the established workflow enables the clinician to achieve precise results in a very efficient way. The innovative five-step concept is presented in a clinical case. © 2014 by the American College of Prosthodontists.

  14. Transapical aortic valve implantation – a rescue procedure for patients with aortic stenosis and “porcelain aorta”

    PubMed Central

    Czerwinska, Katarzyna; Orłowska-Baranowska, Ewa; Witkowski, Adam; Demkow, Marcin; Abramczuk, Elżbieta; Michałek, Piotr; Greszata, Lidia; Stoklosa, Patrycjusz; Kuśmierski, Krzysztof; Kowal, Jaroslaw; Stepinska, Janina

    2011-01-01

    Surgical aortic valve replacement (AVR) still remains the treatment of choice in symptomatic significant aortic stenosis (AS). Due to technical problems, extensive calcification of the ascending aorta (“porcelain aorta”) is an additional risk factor for surgery and transapical aortic valve implantation (TAAVI) is likely to be the only rescue procedure for this group of patients. We describe the case of an 81-year-old woman with severe AS and “porcelain aorta”, in whom the only available life-saving intervention was TAAVI. PMID:22295040

  15. Associations between sleep bruxism and (peri-) implant complications: a prospective cohort study

    PubMed Central

    Thymi, Magdalini; Visscher, Corine M; Yoshida-Kohno, Eiko; Crielaard, Wim; Wismeijer, Daniel; Lobbezoo, Frank

    2017-01-01

    Objectives/Aims: To describe the protocol of a prospective cohort study designed to answer the question: ‘Is sleep bruxism a risk factor for (peri-)implant complications?’. Materials and Methods: Our study is a single-centre, double-blind, prospective cohort study with a follow-up time of 2 years. Ninety-eight participants fulfilling inclusion criteria (planned treatment with implant-supported fixed suprastructure(s) and age 18 years or older) will be included. Sleep bruxism will be monitored at several time points as masticatory muscle activity during sleep by means of a portable single-channel electromyographic device. Our main outcomes are biological complications (i.e., related to peri-implant bleeding, probing depth, marginal bone height, quality of submucosal biofilm and loss of osseointegration) and technical complications (i.e., suprastructure, abutment, implant body or other). Results: The study is currently ongoing, and data are being gathered. Discussion: The results of this prospective cohort study will provide important information for clinicians treating bruxing patients with dental implants. Furthermore, it will contribute to the body of evidence related to the behaviour of dental implants and their complications under conditions of high mechanical loadings that result from sleep bruxism activity. Conclusion: The protocol of a prospective cohort study designed to investigate possible associations between sleep bruxism and (peri-) implant complications was presented. PMID:29607076

  16. Recent advances in pacemaker and implantable defibrillator therapy for young patients.

    PubMed

    Walsh, Edward P; Cecchin, Frank

    2004-03-01

    This review is intended to highlight major clinical advances over the past year related to (1). biventricular pacing as a treatment for dilated myopathy, (2). growing clinical experience with implantable cardioverter defibrillators in pediatrics, (3). technical advances in standard antibradycardia pacing, and (4). an appraisal of the newly updated ACC/AHA/NASPE guidelines for device implant in children and adolescents. Complex rhythm devices are being used more frequently in children. Biventricular pacing to improve ventricular contractility is a rapidly evolving technology that has now been applied to children and young adults with intraventricular conduction delay, such as bundle branch block after cardiac surgery. Implantable defibrillators are also being used for an expanding list of conditions, although lead dysfunction is seen as a fairly common complication in active young patients. Guidelines for device implantation have been developed, but the weight of evidence remains somewhat limited by the paucity of pediatric data in this field. Thanks to refinements in lead design and generator technology, coupled with rapidly expanding clinical indications, pacemakers and implantable defibrillators have become increasingly important components of cardiac therapy for young patients. Expanded multicenter clinical studies will be needed to develop more objective guidelines for use of this advanced technology.

  17. Nitrogen implantation with a scanning electron microscope.

    PubMed

    Becker, S; Raatz, N; Jankuhn, St; John, R; Meijer, J

    2018-01-08

    Established techniques for ion implantation rely on technically advanced and costly machines like particle accelerators that only few research groups possess. We report here about a new and surprisingly simple ion implantation method that is based upon a widespread laboratory instrument: The scanning electron microscope. We show that it can be utilized to ionize atoms and molecules from the restgas by collisions with electrons of the beam and subsequently accelerate and implant them into an insulating sample by the effect of a potential building up at the sample surface. Our method is demonstrated by the implantation of nitrogen ions into diamond and their subsequent conversion to nitrogen vacancy centres which can be easily measured by fluorescence confocal microscopy. To provide evidence that the observed centres are truly generated in the way we describe, we supplied a 98% isotopically enriched 15 N gas to the chamber, whose natural abundance is very low. By employing the method of optically detected magnetic resonance, we were thus able to verify that the investigated centres are actually created from the 15 N isotopes. We also show that this method is compatible with lithography techniques using e-beam resist, as demonstrated by the implantation of lines using PMMA.

  18. First Chance Network and Technical Assistance

    ERIC Educational Resources Information Center

    Trohanis, Pascal L.

    1973-01-01

    Article seeks to cover the following topics: an overview of First Chance; a description of TADS (Technical Assistance Development System); and a discussion of the organization's Media and Information division. (Author)

  19. Study of Navy Enlisted Attrition: Race, Ethnicity, and Type of Occupation

    DTIC Science & Technology

    2008-09-01

    technical job. Further research is recommended to explore these results and to suggest approaches that might assist in lowering attrition rates...technical job than to a technical one; in contrast, most minorities are far more likely to attrite when serving in a technical job. Further research is... HIGH QUALITY (HQ) STATUS ..........................33 IV. RESULTS ................................................35 A. DESCRIPTIVE SUMMARY OF THE

  20. Effect of avocado/soybean unsaponifiables on osseointegration: a proof-of-principle preclinical in vivo study.

    PubMed

    de Oliveira, Guilherme José Pimentel Lopes; de Paula, Luiz Guilherme Freitas; Spin-Neto, Rubens; Stavropoulos, Andreas; Spolidório, Luis Carlos; Marcantonio, Elcio; Marcantonio, Rosemary Adriana Chiérici

    2014-01-01

    To evaluate the influence of administration of avocado/soybean unsaponifiables (ASU) on implant osseointegration in rat tibiae. Thirty rats were randomly assigned into one of three equal-sized groups: (1) ASU1: administration of ASU starting 7 days prior to implant placement; (2) ASU2: administration of ASU starting on the day of implant placement, and (3) CTL: administration of saline solution. In all animals, one titanium implant was placed in each tibia. All animals received ASU or saline solution by gavage daily until sacrifice 60 days postoperatively. Implant osseointegration and bone maturation were assessed by biomechanical and radiographic bone density analysis; descriptive histology; immunohistochemistry for bone morphogenetic protein 2 (BMP-2), transforming growth factor beta 1 (TGF-β1), and osteocalcin; and histomorphometric evaluation of bone-to-implant contact (BIC) and mineralized bone area fraction within the threads of the implant. ASU1 and ASU2 showed three times higher expression of BMP-2 and nine times higher expression of TGF-β1 compared with CTL (P < .05). Histomorphometric analysis, however, showed that both ASU1 and ASU2 groups presented significantly higher BIC values only in the cortical bone compartment when compared to CTL (P < .05). ASU consumption seems to exert only a subtle effect on implant osseointegration.

  1. An Assessment of the Risk of Bias in Randomized Controlled Trial Reports Published in Prosthodontic and Implant Dentistry Journals.

    PubMed

    Papageorgiou, Spyridon N; Kloukos, Dimitrios; Petridis, Haralampos; Pandis, Nikolaos

    2015-01-01

    The objective of this study was to assess the risk of bias of randomized controlled trials (RCTs) published in prosthodontic and implant dentistry journals. The last 30 issues of 9 journals in the field of prosthodontic and implant dentistry (Clinical Implant Dentistry and Related Research, Clinical Oral Implants Research, Implant Dentistry, International Journal of Oral & Maxillofacial Implants, International Journal of Periodontics and Restorative Dentistry, International Journal of Prosthodontics, Journal of Dentistry, Journal of Oral Rehabilitation, and Journal of Prosthetic Dentistry) were hand-searched for RCTs. Risk of bias was assessed using the Cochrane Collaboration's risk of bias tool and analyzed descriptively. From the 3,667 articles screened, a total of 147 RCTs were identified and included. The number of published RCTs increased with time. The overall distribution of a high risk of bias assessment varied across the domains of the Cochrane risk of bias tool: 8% for random sequence generation, 18% for allocation concealment, 41% for masking, 47% for blinding of outcome assessment, 7% for incomplete outcome data, 12% for selective reporting, and 41% for other biases. The distribution of high risk of bias for RCTs published in the selected prosthodontic and implant dentistry journals varied among journals and ranged from 8% to 47%, which can be considered as substantial.

  2. Transcatheter aortic valve implantation using anatomically oriented, marrow stromal cell-based, stented, tissue-engineered heart valves: technical considerations and implications for translational cell-based heart valve concepts.

    PubMed

    Emmert, Maximilian Y; Weber, Benedikt; Behr, Luc; Sammut, Sebastien; Frauenfelder, Thomas; Wolint, Petra; Scherman, Jacques; Bettex, Dominique; Grünenfelder, Jürg; Falk, Volkmar; Hoerstrup, Simon P

    2014-01-01

    While transcatheter aortic valve implantation (TAVI) has rapidly evolved for the treatment of aortic valve disease, the currently used bioprostheses are prone to continuous calcific degeneration. Thus, autologous, cell-based, living, tissue-engineered heart valves (TEHVs) with regeneration potential have been suggested to overcome these limitations. We investigate the technical feasibility of combining the concept of TEHV with transapical implantation technology using a state-of-the-art transcatheter delivery system facilitating the exact anatomical position in the systemic circulation. Trileaflet TEHVs fabricated from biodegradable synthetic scaffolds were sewn onto self-expanding Nitinol stents seeded with autologous marrow stromal cells, crimped and transapically delivered into the orthotopic aortic valve position of adult sheep (n = 4) using the JenaValve transapical TAVI System (JenaValve, Munich, Germany). Delivery, positioning and functionality were assessed by angiography and echocardiography before the TEHV underwent post-mortem gross examination. For three-dimensional reconstruction of the stent position of the anatomically oriented system, a computed tomography analysis was performed post-mortem. Anatomically oriented, transapical delivery of marrow stromal cell-based TEHV into the orthotopic aortic valve position was successful in all animals (n = 4), with a duration from cell harvest to TEHV implantation of 101 ± 6 min. Fluoroscopy and echocardiography displayed sufficient positioning, thereby entirely excluding the native leaflets. There were no signs of coronary obstruction. All TEHV tolerated the loading pressure of the systemic circulation and no acute ruptures occurred. Animals displayed intact and mobile leaflets with an adequate functionality. The mean transvalvular gradient was 7.8 ± 0.9 mmHg, and the mean effective orifice area was 1.73 ± 0.02 cm(2). Paravalvular leakage was present in two animals, and central aortic regurgitation due to a single-leaflet prolapse was detected in two, which was primarily related to the leaflet design. No stent dislocation, migration or affection of the mitral valve was observed. For the first time, we demonstrate the technical feasibility of a transapical TEHV delivery into the aortic valve position using a commercially available and clinically applied transapical implantation system that allows for exact anatomical positioning. Our data indicate that the combination of TEHV and a state-of-the-art transapical delivery system is feasible, representing an important step towards translational, transcatheter-based TEHV concepts.

  3. β-Decay Studies of r-Process Nuclei Using the Advanced Implantation Detector Array (AIDA)

    NASA Astrophysics Data System (ADS)

    Griffin, C. J.; Davinson, T.; Estrade, A.; Braga, D.; Burrows, I.; Coleman-Smith, P. J.; Grahn, T.; Grant, A.; Harkness-Brennan, L. J.; Kiss, G.; Kogimtzis, M.; Lazarus, I. H.; Letts, S. C.; Liu, Z.; Lorusso, G.; Matsui, K.; Nishimura, S.; Page, R. D.; Prydderch, M.; Phong, V. H.; Pucknell, V. F. E.; Rinta-Antila, S.; Roberts, O. J.; Seddon, D. A.; Simpson, J.; Thomas, S. L.; Woods, P. J.

    Thought to produce around half of all isotopes heavier than iron, the r-process is a key mechanism for nucleosynthesis. However, a complete description of the r-process is still lacking and many unknowns remain. Experimental determination of β-decay half-lives and β-delayed neutron emission probabilities along the r-process path would help to facilitate a greater understanding of this process. The Advanced Implantation Detector Array (AIDA) represents the latest generation of silicon implantation detectors for β-decay studies with fast radioactive ion beams. Preliminary results from commissioning experiments demonstrate successful operation of AIDA and analysis of the data obtained during the first official AIDA experiments is now under-way.

  4. Multiple ion beam irradiation for the study of radiation damage in materials

    NASA Astrophysics Data System (ADS)

    Taller, Stephen; Woodley, David; Getto, Elizabeth; Monterrosa, Anthony M.; Jiao, Zhijie; Toader, Ovidiu; Naab, Fabian; Kubley, Thomas; Dwaraknath, Shyam; Was, Gary S.

    2017-12-01

    The effects of transmutation produced helium and hydrogen must be included in ion irradiation experiments to emulate the microstructure of reactor irradiated materials. Descriptions of the criteria and systems necessary for multiple ion beam irradiation are presented and validated experimentally. A calculation methodology was developed to quantify the spatial distribution, implantation depth and amount of energy-degraded and implanted light ions when using a thin foil rotating energy degrader during multi-ion beam irradiation. A dual ion implantation using 1.34 MeV Fe+ ions and energy-degraded D+ ions was conducted on single crystal silicon to benchmark the dosimetry used for multi-ion beam irradiations. Secondary Ion Mass Spectroscopy (SIMS) analysis showed good agreement with calculations of the peak implantation depth and the total amount of iron and deuterium implanted. The results establish the capability to quantify the ion fluence from both heavy ion beams and energy-degraded light ion beams for the purpose of using multi-ion beam irradiations to emulate reactor irradiated microstructures.

  5. Percutaneous Transcatheter One-Step Mechanical Aortic Disc Valve Prosthesis Implantation: A Preliminary Feasibility Study in Swine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sochman, Jan; Peregrin, Jan H.; Rocek, Miloslav

    Purpose. To evaluate the feasibility of one-step implantation of a new type of stent-based mechanical aortic disc valve prosthesis (MADVP) above and across the native aortic valve and its short-term function in swine with both functional and dysfunctional native valves. Methods. The MADVP consisted of a folding disc valve made of silicone elastomer attached to either a nitinol Z-stent (Z model) or a nitinol cross-braided stent (SX model). Implantation of 10 MADVPs (6 Z and 4 SX models) was attempted in 10 swine: 4 (2 Z and 2 SX models) with a functional native valve and 6 (4 Z andmore » 2 SX models) with aortic regurgitation induced either by intentional valve injury or by MADVP placement across the native valve. MADVP function was observed for up to 3 hr after implantation. Results. MADVP implantation was successful in 9 swine. One animal died of induced massive regurgitation prior to implantation. Four MADVPs implanted above functioning native valves exhibited good function. In 5 swine with regurgitation, MADVP implantation corrected the induced native valve dysfunction and the device's continuous good function was observed in 4 animals. One MADVP (SX model) placed across native valve gradually migrated into the left ventricle. Conclusion. The tested MADVP can be implanted above and across the native valve in a one-step procedure and can replace the function of the regurgitating native valve. Further technical development and testing are warranted, preferably with a manufactured MADVP.« less

  6. Clinical Performance of One-Piece, Screw-Retained Implant Crowns Based on Hand-Veneered CAD/CAM Zirconia Abutments After a Mean Follow-up Period of 2.3 Years.

    PubMed

    Schnider, Nicole; Forrer, Fiona Alena; Brägger, Urs; Hicklin, Stefan Paul

    The aim of this study was to evaluate the clinical performance of one-piece, screw-retained implant crowns based on hand-veneered computer-aided design/computer-aided manufacture (CAD/CAM) zirconium dioxide abutments with a crossfit connection at least 1 year after insertion of the crown. Consecutive patients who had received at least one Straumann bone level implant and one-piece, screw-retained implant crowns fabricated with CARES zirconium dioxide abutments were reexamined. Patient satisfaction, occlusal and peri-implant parameters, mechanical and biologic complications, radiologic parameters, and esthetics were recorded. A total of 50 implant crowns in the anterior and premolar region were examined in 41 patients. The follow-up period of the definitive reconstructions ranged from 1.1 to 3.8 years. No technical and no biologic complications had occurred. At the reexamination, 100% of the implants and reconstructions were in situ. Radiographic evaluation revealed a mean distance from the implant shoulder to the first visible bone-to-implant contact of 0.06 mm at the follow-up examination. Screw-retained crowns based on veneered CAD/CAM zirconium dioxide abutments with a crossfit connection seem to be a promising way to replace missing teeth in the anterior and premolar region. In the short term, neither failures of components nor complications were noted, and the clinical and radiographic data revealed stable hard and soft tissue conditions.

  7. 77 FR 41132 - Air Quality Implementation Plans; Alabama; Attainment Plan for the Alabama Portion of the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-12

    ... modeling demonstration should include supporting technical analyses and descriptions of all relevant....5 and NO X . The attainment demonstration includes: Technical analyses that locate, identify, and... modeling analysis is a complex technical evaluation that began with selection of the modeling system. The...

  8. Technical Education and Resource Material.

    ERIC Educational Resources Information Center

    Mills, Marie T.

    New approaches and many technical innovations will be required by the junior college to meet the increasing educational needs of technical occupations. A first is information on which the prospective student can base an intelligent choice of occupation. For this he must have a precise job description to determine whether the career fits his…

  9. 9 CFR 351.5 - Conditions of eligibility for certification service; review of applications.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... technical animal fat, and a written description of the shipping, receiving, and inventory records maintained... PRODUCTS INSPECTION AND VOLUNTARY INSPECTION AND CERTIFICATION CERTIFICATION OF TECHNICAL ANIMAL FATS FOR...”); and such source materials will be rendered at the plant into technical animal fat eligible for export...

  10. 76 FR 35231 - Notice of Proposed Information Collection for Public Comment; McKinney-Vento Technical Assistance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-16

    ... Information Collection for Public Comment; McKinney-Vento Technical Assistance Narrative, Matrices, and... Narrative, Matrices, and Reporting Requirements. Description of the need for the information proposed: McKinney- Vento Technical Assistance (MV-TA) Narrative, Matrices, and Reporting Requirements will allow the...

  11. Development of implant loading device for animal study about various loading protocol: a pilot study

    PubMed Central

    Yoon, Joon-Ho; Park, Young-Bum; Cho, Yuna; Kim, Chang-Sung; Choi, Seong-Ho; Moon, Hong-Seok; Lee, Keun-Woo

    2012-01-01

    PURPOSE The aims of this pilot study were to introduce implant loading devices designed for animal study and to evaluate the validity of the load transmission ability of the loading devices. MATERIALS AND METHODS Implant loading devices were specially designed and fabricated with two implant abutments and cast metal bars, and orthodontic expansion screw. In six Beagles, all premolars were extracted and two implants were placed in each side of the mandibles. The loading device was inserted two weeks after the implant placement. According to the loading protocol, the load was applied to the implants with different time and method,simulating early, progressive, and delayed loading. The implants were clinically evaluated and the loading devices were removed and replaced to the master cast, followed by stress-strain analysis. Descriptive statistics of remained strain (µε) was evaluated after repeating three cycles of the loading device activation. Statistic analysis was performed using nonparametric, independent t-test with 5% significance level and Friedman's test was also used for verification. RESULTS The loading devices were in good action. However, four implants in three Beagles showed loss of osseointegration. In stress-strain analysis, loading devices showed similar amount of increase in the remained strain after applying 1-unit load for three times. CONCLUSION Specialized design of the implant loading device was introduced. The loading device applied similar amount of loads near the implant after each 1-unit loading. However, the direction of the loads was not parallel to the long axis of the implants as predicted before the study. PMID:23236575

  12. Basic concepts in metal work failure after metastatic spine tumour surgery.

    PubMed

    Kumar, Naresh; Patel, Ravish; Wadhwa, Anshuja Charvi; Kumar, Aravind; Milavec, Helena Maria; Sonawane, Dhiraj; Singh, Gurpal; Benneker, Lorin Michael

    2018-04-01

    The development of spinal implants marks a watershed in the evolution of metastatic spine tumour surgery (MSTS), which has evolved from standalone decompressive laminectomy to instrumented stabilization and decompression with reconstruction when necessary. Fusion may not be feasible after MSTS due to poor quality of graft host bed along with adjunct chemotherapy and/or radiotherapy postoperatively. With an increase in the survival of patients with spinal tumours, there is a probability of an increase in the rate of implant failure. This review aims to help establish a clear understanding of implants/constructs used in MSTS and to highlight the fundamental biomechanics of implant/construct failures. Published literature on implant failure after spine surgery and MSTS has been reviewed. The evolution of spinal implants and their role in MSTS has been briefly described. The review defines implant/construct failures using radiological parameters that are practical, feasible, and derived from historical descriptions. We have discussed common modes of implant/construct failure after MSTS to allow further understanding, interception, and prevention of catastrophic failure. Implant failure rates in MSTS are in the range of 2-8%. Variability in patterns of failure has been observed based on anatomical region and the type of constructs used. Patients with construct/implant failures may or may not be symptomatic and present either as early (< 3months) or late failures (> 3months). It has been noted that not all the implant failures after MSTS result in revisions. Based on the observed radiological criteria and clinical presentations, we have proposed a clinico-radiological classification for implant/construct failure after MSTS.

  13. A Systematic Review and Head-to-Head Meta-Analysis of Outcomes following Direct-to-Implant versus Conventional Two-Stage Implant Reconstruction.

    PubMed

    Basta, Marten N; Gerety, Patrick A; Serletti, Joseph M; Kovach, Stephen J; Fischer, John P

    2015-12-01

    Innovative approaches to reconstruction have ushered in an era of breast reconstruction in which direct-to-implant procedures can provide an immediately reconstructed breast. Balancing the benefits against its technical challenges is vital. The authors evaluated the safety and efficacy of using direct-to-implant versus conventional two-stage reconstruction through a systematic meta-analysis. A literature search identified all articles published after 1999 involving prosthetic-based breast reconstruction as a two-stage tissue expander/implant or direct-to-implant technique. The primary outcomes of interest, including implant loss, capsular contracture, reoperation, and infection, were analyzed by means of head-to-head meta-analysis. Thirteen studies involving 5216 breast reconstructions were included. The average patient age was 47.2 ± 1.0 years, the average body mass index was 24.9 ± 0.8 mg/k2, and the average follow-up was 40.8 months. Wound infection, seroma, and capsular contracture risk were similar between groups. However, direct-to-implant reconstruction was associated with a higher risk for skin flap necrosis (OR, 1.43; p = 0.01; I2 = 51 percent) and reoperation (OR, 1.25; p = 0.04; I2 = 43 percent). Ultimately, the risk for implant loss was nearly two-fold higher with direct-to-implant reconstruction compared with tissue expander/implant reconstruction (OR, 1.87; p = 0.04; I2 = 33 percent). Although direct-to-implant and two-stage tissue expander/implant reconstruction are successful approaches, this meta-analysis demonstrates significantly greater risk of flap necrosis and implant failure with direct-to-implant reconstruction. The authors' findings suggest that the critical component of patient selection is judgment of mastectomy flap tissue quality. These findings can enhance the risk counseling process and highlight the need for additional investigations to optimize outcomes.

  14. Parametric model of the scala tympani for haptic-rendered cochlear implantation.

    PubMed

    Todd, Catherine; Naghdy, Fazel

    2005-01-01

    A parametric model of the human scala tympani has been designed for use in a haptic-rendered computer simulation of cochlear implant surgery. It will be the first surgical simulator of this kind. A geometric model of the Scala Tympani has been derived from measured data for this purpose. The model is compared with two existing descriptions of the cochlear spiral. A first approximation of the basilar membrane is also produced. The structures are imported into a force-rendering software application for system development.

  15. Neural prostheses in clinical applications--trends from precision mechanics towards biomedical microsystems in neurological rehabilitation.

    PubMed

    Stieglitz, T; Schuettler, M; Koch, K P

    2004-04-01

    Neural prostheses partially restore body functions by technical nerve excitation after trauma or neurological diseases. External devices and implants have been developed since the early 1960s for many applications. Several systems have reached nowadays clinical practice: Cochlea implants help the deaf to hear, micturition is induced by bladder stimulators in paralyzed persons and deep brain stimulation helps patients with Parkinson's disease to participate in daily life again. So far, clinical neural prostheses are fabricated with means of precision mechanics. Since microsystem technology opens the opportunity to design and develop complex systems with a high number of electrodes to interface with the nervous systems, the opportunity for selective stimulation and complex implant scenarios seems to be feasible in the near future. The potentials and limitations with regard to biomedical microdevices are introduced and discussed in this paper. Target specifications are derived from existing implants and are discussed on selected applications that has been investigated in experimental research: a micromachined implant to interface a nerve stump with a sieve electrode, cuff electrodes with integrated electronics, and an epiretinal vision prosthesis.

  16. Cranioplasty after trephination using a novel biodegradable burr hole cover: technical case report.

    PubMed

    Schantz, Jan-Thorsten; Lim, Thiam-Chye; Ning, Chou; Teoh, Swee Hin; Tan, Kim Cheng; Wang, Shih Chang; Hutmacher, Dietmar Werner

    2006-02-01

    We have developed novel biodegradable polymer implants by using the rapid prototyping technology fused deposition modeling. Early results of a clinical pilot study for cranioplasty are presented. Five patients with the diagnosis of chronic subdural hematoma were included in the study. After trephination and evacuation of the subdural hematoma, burr holes (diameter, 14 mm) were closed using a biodegradable implant made of polycaprolactone. Implants were computer designed with an upper rim diameter of 16 mm and a 14 mm body diameter with a fully interconnected, honeycomb-like architecture of 400 to 600 microm in pore size. Postoperative computed tomographic scans indicated that the plugs were stably anchored in the osseous host environment with no fluid collection detectable. The postoperative course was uneventful, and patients were discharged after 5 days. Follow-up scans after 3, 6, and 12 months showed that the implants were well integrated in the surrounding calvarial bone with new bone filling the porous space. These novel polymer scaffolds made of the slow-degrading material polycaprolactone represent a suitable implant for closure of post-trephination defects.

  17. Mobile communications satellite antenna flight experiment definition

    NASA Technical Reports Server (NTRS)

    Freeland, Robert E.

    1987-01-01

    Results of a NASA-sponsored study to determine the technical feasibility and cost of a Shuttle-based flight experiment specifically intended for the MSAT commercial user community are presented. The experiment will include demonstrations of technology in the areas of radio frequency, sensing and control, and structures. The results of the structural subsystem study summarized here include experiment objective and technical approach, experiment structural description, structure/environment interactions, structural characterization, thermal characterization, structural measurement system, and experiment functional description.

  18. Toxicology and occupational hazards of new materials and processes in metal surface treatment, powder metallurgy, technical ceramics, and fiber-reinforced plastics.

    PubMed

    Midtgård, U; Jelnes, J E

    1991-12-01

    Many new materials and processes are about to find their way from the research laboratory into industry. The present paper describes some of these processes and provides an overview of possible occupational hazards and a list of chemicals used or produced in the processes. The technological areas that are considered are metal surface treatment (ion implantation, physical and chemical vapor deposition, plasma spraying), powder metallurgy, advanced technical ceramics, and fiber-reinforced plastics.

  19. Technical aspects of pediatric epilepsy surgery: Report of a multicenter, multinational web-based survey by the ILAE Task Force on Pediatric Epilepsy Surgery.

    PubMed

    Cukiert, Arthur; Rydenhag, Bertil; Harkness, William; Cross, J Helen; Gaillard, William D

    2016-02-01

    Surgical techniques may vary extensively between centers. We report on a web-based survey aimed at evaluating the current technical approaches in different centers around the world performing epilepsy surgery in children. The intention of the survey was to establish technical standards. A request was made to 88 centers to complete a web-based survey comprising 51 questions. There were 14 questions related to general issues, 13 questions investigating the different technical aspects for children undergoing epilepsy surgery, and 24 questions investigating surgical strategies in pediatric epilepsy surgery. Fifty-two centers covering a wide geographic representation completed the questionnaire. The median number of resective procedures per center per year was 47. Some important technical practices appeared (>80% of the responses) such as the use of prophylactic antibiotics (98%), the use of high-speed drills for bone opening (88%), nonresorbable material for bone flap closure (85%), head fixation (90%), use of the surgical microscope (100%), and of free bone flaps. Other questions, such as the use of drains, electrocorticography (ECoG) and preoperative withdrawal of valproate, led to mixed, inconclusive results. Complications were noted in 3.8% of the patients submitted to cortical resection, 9.9% hemispheric surgery, 5% callosotomy, 1.8% depth electrode implantation, 5.9% subdural grids implantation, 11.9% hypothalamic hamartoma resection, 0.9% vagus nerve stimulation (VNS), and 0.5% deep brain stimulation. There were no major differences across regions or countries in any of the subitems above. The present data offer the first overview of the technical aspects of pediatric epilepsy surgery worldwide. Surprisingly, there seem to be more similarities than differences. That aside many of the evaluated issues should be examined by adequately designed multicenter randomized controlled trials (RCTs). Further knowledge on these technical issues might lead to increased standardization and lower costs in the future, as well as definitive practice guidelines. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  20. An ontology-based annotation of cardiac implantable electronic devices to detect therapy changes in a national registry.

    PubMed

    Rosier, Arnaud; Mabo, Philippe; Chauvin, Michel; Burgun, Anita

    2015-05-01

    The patient population benefitting from cardiac implantable electronic devices (CIEDs) is increasing. This study introduces a device annotation method that supports the consistent description of the functional attributes of cardiac devices and evaluates how this method can detect device changes from a CIED registry. We designed the Cardiac Device Ontology, an ontology of CIEDs and device functions. We annotated 146 cardiac devices with this ontology and used it to detect therapy changes with respect to atrioventricular pacing, cardiac resynchronization therapy, and defibrillation capability in a French national registry of patients with implants (STIDEFIX). We then analyzed a set of 6905 device replacements from the STIDEFIX registry. Ontology-based identification of therapy changes (upgraded, downgraded, or similar) was accurate (6905 cases) and performed better than straightforward analysis of the registry codes (F-measure 1.00 versus 0.75 to 0.97). This study demonstrates the feasibility and effectiveness of ontology-based functional annotation of devices in the cardiac domain. Such annotation allowed a better description and in-depth analysis of STIDEFIX. This method was useful for the automatic detection of therapy changes and may be reused for analyzing data from other device registries.

  1. [Special cannulas for the puncture of implanted catheter port systems].

    PubMed

    Haindl, H; Müller, H

    1989-04-01

    The Huber-Point cannula is generally recommended for portal puncture. Two comparative studies are published that show no advantage in using Huber-point cannulas. This has been verified by technical investigations. A new type of non-coring cannula is described.

  2. Impression of multiple implants using photogrammetry: description of technique and case presentation.

    PubMed

    Peñarrocha-Oltra, David; Agustín-Panadero, Rubén; Bagán, Leticia; Giménez, Beatriz; Peñarrocha, María

    2014-07-01

    To describe a technique for registering the positions of multiple dental implants using a system based on photogrammetry. A case is presented in which a prosthetic treatment was performed using this technique. Three Euroteknika® dental implants were placed to rehabilitate a 55-year-old male patient with right posterior maxillary edentulism. Three months later, the positions of the implants were registered using a photogrammetry-based stereo-camera (PICcamera®). After processing patient and implant data, special abutments (PICabutment®) were screwed onto each implant. The PICcamera® was then used to capture images of the implant positions, automatically taking 150 images in less than 60 seconds. From this information a file was obtained describing the relative positions - angles and distances - of each implant in vector form. Information regarding the soft tissues was obtained from an alginate impression that was cast in plaster and scanned. A Cr-Co structure was obtained using CAD/CAM, and its passive fit was verified in the patient's mouth using the Sheffield test and the screw resistance test. Twelve months after loading, peri-implant tissues were healthy and no marginal bone loss was observed. The clinical application of this new system using photogrammetry to record the position of multiple dental implants facilitated the rehabilitation of a patient with posterior maxillary edentulism by means of a prosthesis with optimal fit. The prosthetic process was accurate, fast, simple to apply and comfortable for the patient.

  3. Dental implants in patients with ectodermal dysplasia: A systematic review.

    PubMed

    Chrcanovic, Bruno Ramos

    2018-05-21

    This study sought to assess the clinical outcome and survival rate of oral implants placed in individuals with ectodermal dysplasia (ED), based on previously published studies. An electronic search without time restrictions was undertaken in 5 databases (PubMed/Medline, Web of Science, ScienceDirect, J-Stage, Lilacs). Descriptive statistics, Kaplan Meier estimator and implant failure probability were calculated. 90 publications were included, reporting 228 ED patients that received 1472 implants (1392 conventional, 47 zygomatic, 33 mini-implants). Mean age of the patients was 20.2 ± 6.8 years (2-56). Patients had a mean of 3.2 ± 2.5 maxillary and 2.1 ± 2.6 mandibular permanent teeth (min-max, 0-14). Patients received a mean of 8.2 ± 3.8 implants (1-20). Most implants were placed in the third decade of life, 24.6% of the implants were placed in children (0-17 years of age). 1391 implants had information on follow-up (72 failures, 5.2%). The 20-year CSR was 84.6%. The probability of failure was 4.5% (95%CI 3.5%-5.6%, p < 0.001). Additional treatments performed were Le Fort I (99 implants, 20 patients, 3.5% failed), grafting (497 implants, 77 patients, 5.2% failed), distraction osteogenesis (79 implants, 16 patients, 10.1% failed). Mean follow-up was 42.9 ± 41.9 months (min-max, 2-240). Dental implants placed in ED patients, either infants or adults, present a high survival rate (20-year CSR 84.6%). Copyright © 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  4. Novel expandable short dental implants in situations with reduced vertical bone height-technical note and first results.

    PubMed

    Reich, Waldemar; Schweyen, Ramona; Heinzelmann, Christian; Hey, Jeremias; Al-Nawas, Bilal; Eckert, Alexander Walter

    2017-10-30

    Short implants often have the disadvantage of reduced primary stability. The present study was conducted to evaluate the feasibility and safety of a new expandable short dental implant system intended to increase primary stability. As a "proof of concept", a prospective clinical cohort study was designed to investigate intraoperative handling, primary and secondary implant stability (resonance frequency analysis), crestal bone changes, implant survival and implant success, of an innovative short expandable screw implant. From 2014 until 2015, 9 patients (7-9-mm vertical bone height) with 30 implants (length 5-7 mm, diameter 3.75-4.1 mm) were recruited consecutively. All 30 implants in the 9 patients (age 44 to 80 years) could be inserted and expanded without intraoperative problems. Over the 3-year follow-up period, the implant success rate was 28/30 (93.3%). The mean implant stability quotients (ISQ) were as follows: primary stability, 69.7 ± 10.3 ISQ units, and secondary stability, 69.8 ± 10.2 ISQ units (p = 0.780), both without significant differences between the maxilla and mandible (p ≥ 0.780). The mean crestal bone changes after loading were (each measured from the baseline) as follows: in the first year, 1.0 ± 0.9 mm in the maxilla and 0.7 ± 0.4 mm in the mandible, and in the second year, 1.3 ± 0.8 mm and 1.0 ± 0.7 mm, respectively. Compared to other prospective studies, in this indication, the success rate is acceptable. Implant stability shows high initial and secondary stability values. The system might present an extension of functional rehabilitation to the group of elderly patients with limited vertical bone height. Further long-term investigations should directly compare this compressive implant with standard short implants.

  5. Perceval S aortic valve implantation in an achondroplastic Dwarf

    PubMed Central

    Baikoussis, Nikolaos G.; Argiriou, Michalis; Argiriou, Orestis; Dedeilias, Panagiotis

    2016-01-01

    Despite cardiovascular disease in patients with dwarfism is not rare; there is a lack of reports referring to cardiac interventions in such patients. Dwarfism may be due to achondroplasia or hormonal growth disorders. We present a 58-year-old woman with episodes of dyspnea for several months. She underwent on transthoracic echocardiography, and she diagnosed with severe aortic valve stenosis. She referred to our department for surgical treatment of this finding. In accordance of her anthropometric characteristics and her very small aortic annulus, we had the dilemma of prosthesis selection. We decided to implant a stentless valve to optimize her effective orifice area. Our aim is to present the successful Perceval S valve implantation and the descriptions of the problems coming across in operating on these special patients. To our knowledge, this is the first case patient in which a Perceval S valve is implanted according to the international bibliography. PMID:26750695

  6. Effects of Leadership Styles in Technical and Vocational Students, UTHM

    ERIC Educational Resources Information Center

    Razak, Nur Afifah Binti Abdul; Hamidon, Nur Izeanty Binti

    2015-01-01

    Effective leadership helps our nation through times become a developed country. This study was undertaken to investigate the effects of leadership style among students in Technical and Vocational at University Tun Hussein Onn Malaysia. Descriptive study carried out to evaluate student leadership. The study sample consisted of 319 Technical and…

  7. Impression of multiple implants using photogrammetry: Description of technique and case presentation

    PubMed Central

    Peñarrocha-Oltra, David; Agustín-Panadero, Rubén; Bagán, Leticia; Giménez, Beatriz

    2014-01-01

    Aim: To describe a technique for registering the positions of multiple dental implants using a system based on photogrammetry. A case is presented in which a prosthetic treatment was performed using this technique. Study Design: Three Euroteknika® dental implants were placed to rehabilitate a 55-year-old male patient with right posterior maxillary edentulism. Three months later, the positions of the implants were registered using a photogrammetry-based stereo-camera (PICcamera®). After processing patient and implant data, special abutments (PICabutment®) were screwed onto each implant. The PICcamera® was then used to capture images of the implant positions, automatically taking 150 images in less than 60 seconds. From this information a file was obtained describing the relative positions – angles and distances – of each implant in vector form. Information regarding the soft tissues was obtained from an alginate impression that was cast in plaster and scanned. A Cr-Co structure was obtained using CAD/CAM, and its passive fit was verified in the patient’s mouth using the Sheffield test and the screw resistance test. Results and Conclusions: Twelve months after loading, peri-implant tissues were healthy and no marginal bone loss was observed. The clinical application of this new system using photogrammetry to record the position of multiple dental implants facilitated the rehabilitation of a patient with posterior maxillary edentulism by means of a prosthesis with optimal fit. The prosthetic process was accurate, fast, simple to apply and comfortable for the patient. Key words:Dental implants, photogrammetry, dental impression technique, CAD/CAM. PMID:24608216

  8. The NASA/MSFC global reference atmospheric model: 1990 version (GRAM-90). Part 1: Technical/users manual

    NASA Technical Reports Server (NTRS)

    Justus, C. G.; Alyea, F. N.; Cunnold, D. M.; Jeffries, W. R., III; Johnson, D. L.

    1991-01-01

    A technical description of the NASA/MSFC Global Reference Atmospheric Model 1990 version (GRAM-90) is presented with emphasis on the additions and new user's manual descriptions of the program operation aspects of the revised model. Some sample results for the new middle atmosphere section and comparisons with results from a three dimensional circulation model are provided. A programmer's manual with more details for those wishing to make their own GRAM program adaptations is also presented.

  9. 75 FR 4136 - Pipeline Safety: Requests for Special Permit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-26

    ... technical analysis or other supporting documentation provided by the requestor, including a description of...: Kay McIver by telephone at (202) 366-0113; or, e-mail at [email protected] . Technical: Steve Nanney...

  10. Prognosis of Combining Remaining Teeth and Implants in Double-Crown-Retained Removable Dental Prostheses: A Systematic Review and Meta-Analysis.

    PubMed

    Lian, Meifei; Zhao, Kai; Feng, Yunzhi; Yao, Qian

    The reliability of combining natural teeth and implants in one removable prosthesis is controversial. This systematic review was conducted to evaluate the prognosis of combined tooth/implant-supported double-crown-retained removable dental prostheses (DCR-RDPs) and to compare them with solely implant-supported prostheses with a minimum observation period of 3 years. Electronic database (PubMed, Embase, Central, and SCI) and manual searches up to August 2016 were conducted to identify human clinical studies on tooth/implant-supported DCR-RDPs. Literature selection and data extraction were accomplished by two independent reviewers. Meta-analyses of survival and complication rates were performed separately for combined tooth/implant-supported and solely implant-supported DCRRDPs. Among the initially identified 366 articles, 17 were included in a quantitative analysis. The estimated overall cumulative survival rate (CSR) for implants in combined tooth/implant-supported DCRRDPs was 98.72% (95% confidence interval [95% CI]: 96.98% to 99.82%), and that for implants in solely implant-supported DCR-RDPs was 98.83% (95% CI: 97.45% to 99.75%). The summary CSR for abutment teeth was 92.96% (95% CI: 85.38% to 98.12%). Double-crown-retained dentures with both abutment types showed high CSRs, most of which were approximately 100%. Regarding prosthetic maintenance treatment, the estimated incidence for patients treated with combined tooth/implant-supported RDPs was 0.164 (95% CI: 0.089 to 0.305) per patient per year (T/P/Y) and that for patients restored with solely implant-supported RDPs was 0.260 (95% CI: 0.149 to 0.454) T/P/Y. Based on four studies with combined tooth/implant-supported DCR-RDPs, no intrusion phenomena were encountered. Subject to the limitations of the present review, combining remaining teeth and implants in DCR-RDPs is a reliable and predictable treatment modality for partially edentulous patients. Comparable high survival rates and minor biologic or technical complications are observed for combined tooth/implant-supported and solely implant-supported DCR-RDPs. Due to the heterogeneity of the included studies, the results must be interpreted with caution.

  11. Abutment misfit in implant-supported prostheses manufactured by casting technique: An integrative review

    PubMed Central

    Pereira, Lorena M. S.; Sordi, Mariane B.; Magini, Ricardo S.; Calazans Duarte, Antônio R.; M. Souza, Júlio C.

    2017-01-01

    The aim of this study was to perform an integrative review of the literature on the clinically usual prosthesis-abutment misfit over implant-supported structures manufactured by conventional casting technique. The present integrative review used the PRISMA methodology. A bibliographical search was conducted on the following electronic databases: MEDLINE/PubMed (National Library of Medicine), Scopus (Elsevier), ScienceDirect (Elsevier), Web of Science (Thomson Reuters Scientific), Latin American and Caribbean Center on Health Sciences Information (BIREME), and Virtual Health Library (BVS). A total of 11 relevant studies were selected for qualitative analysis. The prosthetic-abutment vertical misfit considered clinically usual ranged from 50 to 160 μm. The vertical misfit depends on several steps during technical manufacturing techniques, which includes the materials and technical procedures. Lower values in misfit are recorded when precious metal or titanium alloys are utilized. Although a vertical misfit mean value of 100 μm has been considered clinically usual, most of the previous studies included in this revision showed lower mean values. PMID:29279686

  12. Esthetic abutment design for angulated screw channels: A technical report.

    PubMed

    Sakamoto, Satoshi; Ro, Munehiko; Al Ardah, Aladdin; Goodacre, Charles

    2017-11-15

    Angulated screw channel system abutments (ASCs) have recently been introduced to address the problem with visible screw access that may compromise esthetics. ASCs allow the screw access to be modified up to 25 degrees relative to the implant axis. However, a widened channel, which may cause thinning of the facial ceramic, is needed at the implant screw head to allow for proper engagement of the screwdriver. This technical report introduces a custom titanium insert design, the Satoshi Sakamoto (SS) abutment. The SS abutment consists of a custom titanium metal insert and zirconia coping in which the access hole is located in an esthetic position with an ASC system. The SS abutment results in a crown with more normal crown dimensions that also provides more space for the soft tissues. This SS abutment design allows clinicians to obtain screw-retained restorations with optimal esthetics and mechanical strength. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  13. Revision total hip arthroplasty: the femoral side using cemented implants.

    PubMed

    Holt, Graeme; Hook, Samantha; Hubble, Matthew

    2011-02-01

    Advances in surgical technique and implant technology have improved the ten-year survival after primary total hip arthroplasty (THA). Despite this, the number of revision procedures has been increasing in recent years, a trend which is predicted to continue into the future. Revision THA is a technically demanding procedure often complicated by a loss of host bone stock which may be compounded by the need to remove primary implants. Both cemented and uncemented implant designs are commonly used in the United Kingdom for primary and revision THA and much controversy still exists as to the ideal method of stem fixation. In this article we discuss revision of the femur using cemented components during revision THA. We focus on three clinical scenarios including femoral cement-in-cement revision where the primary femoral cement-bone interface remains well fixed, femoral cement-in-cement revision for peri-prosthetic femoral fractures, and femoral impaction grafting. We discuss the clinical indications, surgical techniques and clinical outcomes for each of these procedures.

  14. [Technical advancements in cochlear implants : State of the art].

    PubMed

    Büchner, A; Gärtner, L

    2017-04-01

    Twenty years ago, cochlear implants (CI) were indicated only in cases of profound hearing loss or complete deafness. While from today's perspective the technology was clumsy and provided patients with only limited speech comprehension in quiet scenarios, successive advances in CI technology and the consequent substantial hearing improvements over time have since then resulted in continuous relaxation of indication criteria toward residual hearing. While achievements in implant and processor electronics have been one key factor for the ever-improving hearing performance, development of electro-acoustic CI systems-together with atraumatic implantation concepts-has led to enormous improvements in patients with low-frequency residual hearing. Manufactures have designed special processors with integrated hearing aid components for this patient group, which are capable of conveying acoustic and electric stimulation. A further milestone in improvement of hearing in challenging listening environments was the adoption of signal enhancement algorithms and assistive listening devices from the hearing aid industry. This article gives an overview of the current state of the art in the abovementioned areas of CI technology.

  15. Additively manufactured sub-periosteal jaw implants.

    PubMed

    Mommaerts, M Y

    2017-07-01

    Severe bone atrophy jeopardizes the success of endosseous implants. This technical note aims to present the innovative concept of additively manufactured sub-periosteal jaw implants (AMSJIs). Digital datasets of the patient's jaws and wax trial in occlusion are used to segment the bone and dental arches, for the design of a sub-periosteal frame and abutments in the optimal location related to the dental arch and for the design of the suprastructure. The implants and suprastructure are three-dimensionally (3D) printed in titanium alloy. The provisional denture is 3D-printed in polymer. AMSJIs offer an alternative approach for patients with extreme jaw bone atrophy. This report refers to the use of this technique for full maxillary rehabilitation, but partial defects in either jaw and extended post-resection defects may also be approached using the same technique. This customized, prosthesis-driven reverse-engineering approach avoids bone grafting and provides immediate functional restoration with one surgical session. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  16. Subcutaneous implantation of satellite transmitters with percutaneous antennae into male polar bears (Ursus maritimus)

    USGS Publications Warehouse

    Mulcahy, Daniel M.; Garner, Gerald W.

    1999-01-01

    Male polar bears (Ursus maritimus) have not been successfully instrumented with satellite transmitters because they readily shed collar-mounted transmitters. Seven male polar bears were captured on the pack ice off the northern coast of Alaska and surgically implanted with satellite transmitters with percutaneous antennae into the subcutaneous space of the dorsal cervical region. Transmitters failed prematurely with lifetimes of 30-161 days (x̄ = 97 days). Efforts to relocate implanted bears after transmitters failed were not successful. The mean number of location solutions per transmitter was 204 (range 118-369). An average of 10% and 19% of the locations were accurate to <150 m and to 150-350 m, respectively. Our successful tracking of male polar bears, the high quality of locations obtained from transmitters with percutaneous antennae implanted in the subcutaneous space, and the low visibility of such units make further technical development worthwhile if the reason for premature failure of the transmitters can be determined.

  17. Assessing the acceptability of NORPLANT implants in four countries: findings from focus group research.

    PubMed

    Zimmerman, M; Haffey, J; Crane, E; Szumowski, D; Alvarez, F; Bhiromrut, P; Brache, V; Lubis, F; Salah, M; Shaaban, M

    1990-01-01

    In 1986-87, a qualitative research project was conducted in the Dominican Republic, Egypt, Indonesia, and Thailand to expand understanding of the acceptability of NORPLANT contraceptive implants beyond inferences made on the basis of continuation rates. In each of the four study sites, focus group discussions or in-depth interviews were held with potential acceptors, current NORPLANT users, discontinuers, husbands of women in these three groups, and service providers. Nonclinical participants generally had little formal education and lived primarily in urban or semi-urban areas where NORPLANT has been available for at least five years. The study focused on attitudes, perceptions, and experiences of each group regarding NORPLANT implants. Results suggest that factors having an impact on the acceptability of NORPLANT implants fall into three general categories: medical/technical, cultural/religious, and informational/educational. This article discusses each of these categories, including programmatic implications of the findings, and puts forward recommendations for enhancing NORPLANT introduction efforts on the basis of these findings.

  18. Application of ion implantation in tooling industry

    NASA Astrophysics Data System (ADS)

    Straede, Christen A.

    1996-06-01

    In papers published during the last half of the 1980s it is often stated that the application of ion beams to non-semiconductor purposes seems ready for full-scale industrial exploitation. However, progress with respect to commercialisation of ion implantation has been slower than predicted, although the process is quite clearly building up niche markets, especially in the tooling industry. It is the main purpose of this paper to discuss the implementation of the process in the tooling market, and to describe strategies used to ensure its success. The basic idea has been to find niches where ion implantation out-performs other processes both technically and in prices. For instance, it has been clearly realised that one should avoid competing with physical vapour deposition or other coating techniques in market areas where they perform excellently, and instead find niches where the advantages of the ion implantation technique can be fully utilised. The paper will present typical case stories in order to illustrate market niches where the technique has its greatest successes and potential.

  19. Computer-assisted surgery in the lower jaw: double surgical guide for immediately loaded implants in postextractive sites-technical notes and a case report.

    PubMed

    De Santis, Daniele; Canton, Luciano Claudio; Cucchi, Alessandro; Zanotti, Guglielmo; Pistoia, Enrico; Nocini, Pier Francesco

    2010-01-01

    Computer-assisted surgery is based on computerized tomography (CT) scan technology to plan the placement of dental implants and a computer-aided design/computer-aided manufacturing (CAD-CAM) technology to create a custom surgical template. It provides guidance for insertion implants after analysis of existing alveolar bone and planning of implant position, which can be immediately loaded, therefore achieving esthetic and functional results in a surgical stage. The absence of guidelines to treat dentulous areas is often due to a lack of computer-assisted surgery. The authors have attempted to use this surgical methodology to replace residual teeth with an immediate implantoprosthetic restoration. The aim of this case report is to show the possibility of treating a dentulous patient by applying a computer-assisted surgical protocol associated with the use of a double surgical template: one before extraction and a second one after extraction of selected teeth.

  20. ANNUAL REPORT, JULY 1, 1957

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1958-10-31

    The progress and trends of research are presented along with a description of operational, service, end administrative activities. Some scientific and technical details are given on research programs in the physical sciences, life sciences, and engineering, however, more complete technical information is available in quarterly progress reports, BNL technical reports, and scientific and technical periodicals. A bibliography of these publications is appended. (For preceding period see BNL-426.) (D.E.B.)

  1. Curriculum Programs in Action, Their Administration and Evaluation; Report of a Conference Devoted to Description, Demonstration, and Evaluative Discussions of Innovative Programs in Vocational-Technical Education.

    ERIC Educational Resources Information Center

    San Francisco State Coll., CA. Center for Technological Education.

    The presentation, review and evaluation of innovative vocational-technical curriculums in operation was the major function of a San Francisco conference sponsored jointly by the Center for Technical Education at San Francisco State College and the Center for Studies in Vocational and Technical Education at the University of Wisconsin. Major…

  2. Surgeons' Perspectives on Premium Implants in Total Joint Arthroplasty.

    PubMed

    Wasterlain, Amy S; Bello, Ricardo J; Vigdorchik, Jonathan; Schwarzkopf, Ran; Long, William J

    2017-09-01

    Declining total joint arthroplasty reimbursement and rising implant prices have led many hospitals to restrict access to newer, more expensive total joint arthroplasty implants. The authors sought to understand arthroplasty surgeons' perspectives on implants regarding innovation, product launch, costs, and cost-containment strategies including surgeon gain-sharing and patient cost-sharing. Members of the International Congress for Joint Reconstruction were surveyed regarding attitudes about implant technology and costs. Descriptive and univariate analyses were performed. A total of 126 surgeons responded from all 5 regions of the United States. Although 76.9% believed new products advance technology in orthopedics, most (66.7%) supported informing patients that new implants lack long-term clinical data and restricting new implants to a small number of investigators prior to widespread market launch. The survey revealed that 66.7% would forgo gain-sharing incentives in exchange for more freedom to choose implants. Further, 76.9% believed that patients should be allowed to pay incremental costs for "premium" implants. Surgeons who believed that premium products advance orthopedic technology were more willing to forgo gain-sharing (P=.040). Surgeons with higher surgical volume (P=.007), those who believed implant companies should be allowed to charge more for new technology (P<.001), and those who supported discussing costs with patients (P=.004) were more supportive of patient cost-sharing. Most arthroplasty surgeons believe technological innovation advances the field but support discussing the "unproven" nature of new implants with patients. Many surgeons support alternative payment models permitting surgeons and patients to retain implant selection autonomy. Most respondents prioritized patient beneficence and surgeon autonomy above personal financial gain. [Orthopedics. 2017; 40(5):e825-e830.]. Copyright 2017, SLACK Incorporated.

  3. Implant Removal After Internal Fixation of a Femoral Neck Fracture: Effects on Physical Functioning.

    PubMed

    Zielinski, Stephanie M; Heetveld, Martin J; Bhandari, Mohit; Patka, Peter; Van Lieshout, Esther M M

    2015-09-01

    The effect of implant removal after internal fixation of a femoral neck fracture on physical functioning was analyzed. Characteristics of patients who had their implant removed were studied, as it is currently unknown from which type of patients implants are removed and what effect removal has on function. Secondary cohort study alongside a randomized controlled trial. Multicenter study in 14 hospitals. Patients who had their implant removed after internal fixation of a femoral neck fracture are compared with patients who did not. Patient characteristics and quality of life (Short Form 12, Western Ontario McMaster Osteoarthritis Index) were compared. Matched pairs were selected based on patient/fracture characteristics and prefracture physical functioning. Of 162 patients, 37 (23%) had their implant removed. These patients were younger (median age: 67 vs. 72 years, P = 0.024) and more often independently ambulatory prefracture (100% vs. 84%, P = 0.008) than patients who did not. They more often had evident implant back-out on x-rays (54% vs. 34%, P = 0.035), possibly related to a higher rate of Pauwels 3 fractures (41% vs. 22%, P = 0.032). In time, quality of life improved more in implant removal patients [+2 vs. -4 points, Short Form 12 (physical component), P = 0.024; +9 vs. 0 points, Western Ontario McMaster Osteoarthritis Index, P = 0.019]. Implant removal after internal fixation of a femoral neck fracture positively influenced quality of life. Implant removal patients were younger and more often independently ambulatory prefracture, more often had a Pauwels 3 fracture, and an evident implant back-out. Implant removal should be considered liberally for these patients if pain persists or functional recovery is unsatisfactory. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.

  4. [Current requirements for polymeric biomaterials in ear, nose and throat medicine].

    PubMed

    Sternberg, K

    2009-05-01

    In recent years the ear, nose and throat medicine (ENT medicine) has been stimulated by numerous innovations in the field of implants which are based on new biomaterials and modern implant technologies. In this context, biomaterials integrated in living organisms have to allow for the technical requirements and the biological interactions between the implant and the tissue. With regard to their suitability, functional capability of the implant, which is complementary to the mechanical implant properties, sufficient stability against physiological media, as well as high biocompatibility are to be demanded. Another purpose of the use of biomaterials is the maintenance and the enhancement of biofunctionality over a long time period. These general requirements for biomaterials also have their validity in ENT medicine. Different materials are applied as biomaterials. Metals belong to the oldest biomaterials. In addition, alloys, ceramics, inorganic glasses and composites were tested. Furthermore, natural and synthetic polymers, which are primarily presented in this article regarding their properties and their applications as materials for cochlear implants, osteosynthesis implants, stents and novel scaffolds for tissue engineering, are increasingly applied. According to their use in permanent and temporary implants, polymers are to be differentiated between biostable and biodegradable polymers. The presented general and current requirements for biomaterials and biomaterial applications in ENT medicine demonstrate key aspects of the current biomaterial research in this field. They do as well document the high impact of the interdisciplinary collaboration of natural and medical scientists and engineers.

  5. Rehabilitation with 4 zygomatic implants with a new surgical protocol using ultrasonic technique.

    PubMed

    Mozzati, Marco; Mortellaro, Carmen; Arata, Valentina; Gallesio, Giorgia; Previgliano, Valter

    2015-05-01

    When the residual bone crest cannot allow the placement of standard implants, the treatment for complete arch rehabilitation of severely atrophic maxillae can be performed with 4 zygomatic implants (ZIs) and immediate function with predictable results in terms of aesthetics, function, and comfort for the patient. However, even if ZIs' rehabilitations showed a good success rate, this surgery is difficult and need a skillful operator. Complications in this kind of rehabilitation are not uncommon; the main difficulties can be related to the reduced surgical visibility and instrument control in a critical anatomic area. All the surgical protocols described in the literature used drilling techniques. Furthermore, the use of ultrasonic instruments in implant surgery compared with drilling instruments have shown advantages in many aspects of surgical procedures, tissues management, enhancement of control, surgical visualization, and healing. The aim of this study was to report on the preliminary experience using ultrasound technique for ZIs surgery in terms of safety and technical improvement. Ten consecutive patients with severely atrophic maxilla have been treated with 4 ZIs and immediate complete arch acrylic resin provisional prostheses. The patients were followed up from 30 to 32 months evaluating implant success, prosthetic success, and patient satisfaction with a questionnaire. No implants were lost during the study period, with a 100% implant and prosthetic success rate. Within the limitations of this preliminary study, these data indicate that ultrasonic implant site preparation for ZIs can be a good alternative to the drilling technique and an improvement for the surgeon.

  6. The Modified Rambo Transcanal Approach for Cochlear Implantation in CHARGE Syndrome.

    PubMed

    Wick, Cameron C; Moore, Amy M; Killeen, Daniel E; Isaacson, Brandon

    2017-10-01

    CHARGE syndrome is associated with a variety of temporal bone anomalies and deafness. The lack of surgical landmarks and facial nerve irregularities make cochlear implantation in this population a challenging endeavor. This study aims to describe a safe and efficacious transcanal approach for cochlear implantation that obviates the need to perform a mastoidectomy and facial recess. Three children with profound hearing loss secondary to CHARGE syndrome. Transcanal cochlear implantation with closure of the ear canal via a modified Rambo meatoplasty. Retrospective chart review of temporal bone anomalies associated with CHARGE syndrome, technical nuances of this transcanal approach, and cochlear implant outcomes. The mean patient age was 2.5 years (range 1.5-3.8 yr). Two were male and two were left ears. All patients had a hypoplastic mastoid, semicircular canal aplasia, and had some degree of cochlear dysplasia. A full cochlear implant insertion was achieved in all cases, even in the presence of grossly abnormal middle ear and facial nerve anatomy. There were no intraoperative or postoperative complications. The mean follow-up was 12.4 months (range, 3.9-25.2 mo). All three patients use their device daily. Their guardians report improved vocalization and environmental awareness. The modified Rambo transcanal approach provides a safe corridor for cochlear implantation in patients with CHARGE syndrome. This approach minimizes the anatomical variations associated with the syndrome and may reduce the risk of electrode extrusion. Implant outcomes in this patient population remain highly variable based on the patient's global cognitive capacity.

  7. The role of autologous chondrocyte implantation in the treatment of symptomatic chondromalacia patellae.

    PubMed

    Macmull, Simon; Jaiswal, Parag K; Bentley, George; Skinner, John A; Carrington, Richard W J; Briggs, Tim W R

    2012-07-01

    Chondromalacia patella is a distinct clinical entity of abnormal softening of the articular cartilage of the patella, which results in chronic retropatellar pain. Its aetiology is still unclear but the process is thought to be a due to trauma to superficial chondrocytes resulting in a proteolytic enzymic breakdown of the matrix. Our aim was to assess the effectiveness of autologous chondrocyte implantation on patients with a proven symptomatic retropatellar lesion who had at least one failed conventional marrow-stimulating therapy. We performed chondrocyte implantation on 48 patients: 25 received autologous chondrocyte implantation with a type I/III membrane (ACI-C) method (Geistlich Biomaterials, Wolhusen, Switzerland), and 23 received the Matrix-assisted Chondrocyte Implantation (MACI) technique (Genzyme, Kastrup, Denmark). Over a mean follow-up period of 40.3 months, there was a statistically significant improvement in subjective pain scoring using the visual analogue scale (VAS) and objective functional scores using the Modified Cincinnati Rating System (MCS) in both groups. Chondromalacia patellae lesions responded well to chondrocyte implantation. Better results occurred with MACI than with ACI-C. Excellent and good results were achieved in 40% of ACI-C patients and 57% of MACI patients, but success of chondrocyte implantation was greater with medial/odd-facet lesions. Given that the MACI procedure is technically easier and less time consuming, we consider it to be useful for treating patients with symptomatic chondral defects secondary to chondromalacia patellae.

  8. Biomaterials in cochlear implants

    PubMed Central

    Stöver, Timo; Lenarz, Thomas

    2011-01-01

    The cochlear implant (CI) represents, for almost 25 years now, the gold standard in the treatment of children born deaf and for postlingually deafened adults. These devices thus constitute the greatest success story in the field of ‘neurobionic’ prostheses. Their (now routine) fitting in adults, and especially in young children and even babies, places exacting demands on these implants, particularly with regard to the biocompatibility of a CI’s surface components. Furthermore, certain parts of the implant face considerable mechanical challenges, such as the need for the electrode array to be flexible and resistant to breakage, and for the implant casing to be able to withstand external forces. As these implants are in the immediate vicinity of the middle-ear mucosa and of the junction to the perilymph of the cochlea, the risk exists – at least in principle – that bacteria may spread along the electrode array into the cochlea. The wide-ranging requirements made of the CI in terms of biocompatibility and the electrode mechanism mean that there is still further scope – despite the fact that CIs are already technically highly sophisticated – for ongoing improvements to the properties of these implants and their constituent materials, thus enhancing the effectiveness of these devices. This paper will therefore discuss fundamental material aspects of CIs as well as the potential for their future development. PMID:22073103

  9. Results from the Tack Optimized Balloon Angioplasty (TOBA) study demonstrate the benefits of minimal metal implants for dissection repair after angioplasty.

    PubMed

    Bosiers, Marc; Scheinert, Dierk; Hendriks, Jeroen M H; Wissgott, Christian; Peeters, Patrick; Zeller, Thomas; Brodmann, Marianne; Staffa, Robert

    2016-07-01

    The mechanism of angioplasty is disruption of atherosclerotic plaque, which often results in dissections. Dissection after percutaneous transluminal angioplasty (PTA) remains a significant clinical problem and untreated may cause acute occlusion or later restenosis. Stents are used to manage dissections, which is often followed by in-stent restenosis and occasionally stent fracture. Tack (Intact Vascular, Wayne, Pa) implants have minimal metal and low radial force and are specifically designed for dissection repair. This study evaluated Tack implants for treatment of dissections resulting from standard balloon PTA for femoral-popliteal arterial disease. Twelve-month outcomes after Tack treatment of post-PTA dissections are described. This prospective, single-arm study evaluated patients with ischemia (Rutherford clinical category 2-4) caused by lesions of the superficial femoral and popliteal arteries. Patients were treated with standard balloon angioplasty, and post-PTA dissections were treated with Tacks. The primary end points were core laboratory-adjudicated device technical success, defined as the ability of the Tack implants to resolve post-PTA dissection, and device safety, defined as the absence of new-onset major adverse events. Patients were followed up to 12 months after implantation. Tacks were used in 130 patients with post-PTA dissections (74.0% ≥ grade C). Technical success was achieved in 128 (98.5%) patients with no major adverse events at 30 days. The 12-month patency was 76.4%, and freedom from target lesion revascularization was 89.5%. Significant improvement from baseline was observed in Rutherford clinical category (82.8% with grade ≤1) and ankle-brachial index (0.68 ± 0.18 to 0.94 ± 0.15; P < .0001). Tack implant treatment of post-PTA dissection was safe, produced reasonable patency, and resulted in low rates of target lesion revascularization. Tack treatment represents a new, minimal metal paradigm for dissection repair that can safely improve the clinical results associated with PTA. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  10. Computed Tomographic Analysis of Ventral Atlantoaxial Optimal Safe Implantation Corridors in 27 Dogs.

    PubMed

    Leblond, Guillaume; Gaitero, Luis; Moens, Noel M M; Zur Linden, Alex; James, Fiona M K; Monteith, Gabrielle J; Runciman, John

    2017-11-01

    Objectives  Ventral atlantoaxial stabilization techniques are challenging surgical procedures in dogs. Available surgical guidelines are based upon subjective anatomical landmarks, and limited radiographic and computed tomographic data. The aims of this study were (1) to provide detailed anatomical descriptions of atlantoaxial optimal safe implantation corridors to generate objective recommendations for optimal implant placements and (2) to compare anatomical data obtained in non-affected Toy breed dogs, affected Toy breed dogs suffering from atlantoaxial instability and non-affected Beagle dogs. Methods  Anatomical data were collected from a prospectively recruited population of 27 dogs using a previously validated method of optimal safe implantation corridor analysis using computed tomographic images. Results  Optimal implant positions and three-dimensional numerical data were generated successfully in all cases. Anatomical landmarks could be used to generate objective definitions of optimal insertion points which were applicable across all three groups. Overall the geometrical distribution of all implant sites was similar in all three groups with a few exceptions. Clinical Significance  This study provides extensive anatomical data available to facilitate surgical planning of implant placement for atlantoaxial stabilization. Our data suggest that non-affected Toy breed dogs and non-affected Beagle dogs constitute reasonable research models to study atlantoaxial stabilization constructs. Schattauer GmbH Stuttgart.

  11. [Abscess at the implant site following apical parodontitis. Hardware-related complications of deep brain stimulation].

    PubMed

    Sixel-Döring, F; Trenkwalder, C; Kappus, C; Hellwig, D

    2006-08-01

    Deep brain stimulation of the subthalamic nucleus is an important treatment option for advanced stages of idiopathic Parkinson's disease, leading to significant improvement of motor symptoms in suited patients. Hardware-related complications such as technical malfunction, skin erosion, and infections however cause patient discomfort and additional expense. The patient presented here suffered a putrid infection of the impulse generator site following only local dental treatment of apical parodontitis. Therefore, prophylactic systemic antibiotic treatment is recommended for patients with implanted deep brain stimulation devices in case of operations, dental procedures, or infectious disease.

  12. Flow Changes after Endovascular Treatment of a Wide-Neck Anterior Communicating Artery Aneurysm by using X-configured Kissing Stents (Cross-Kissing Stents) Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zelenak, Kamil, E-mail: zelenak@unm.sk; Zelenakova, Jana; DeRiggo, Julius

    2011-12-15

    Endovascular treatment for a wide-neck anterior communicating artery (AcomA) aneurysm remains technically challenging. Stent-assisted embolization has been proposed as an alternative of treatment of complex aneurysms. The X-configuration double-stent-assisted technique was used to achieve successful coiling of wide-neck AcomA aneurysm. Implanted stent can alter intra-arterial flow. Follow-up angiograms 4 months later showed flow changes due to used X-technique of stents implantation and filling of the anterior cerebral artery from the opposite internal carotid artery.

  13. Auditory Speech Perception Tests in Relation to the Coding Strategy in Cochlear Implant.

    PubMed

    Bazon, Aline Cristine; Mantello, Erika Barioni; Gonçales, Alina Sanches; Isaac, Myriam de Lima; Hyppolito, Miguel Angelo; Reis, Ana Cláudia Mirândola Barbosa

    2016-07-01

    The objective of the evaluation of auditory perception of cochlear implant users is to determine how the acoustic signal is processed, leading to the recognition and understanding of sound. To investigate the differences in the process of auditory speech perception in individuals with postlingual hearing loss wearing a cochlear implant, using two different speech coding strategies, and to analyze speech perception and handicap perception in relation to the strategy used. This study is prospective cross-sectional cohort study of a descriptive character. We selected ten cochlear implant users that were characterized by hearing threshold by the application of speech perception tests and of the Hearing Handicap Inventory for Adults. There was no significant difference when comparing the variables subject age, age at acquisition of hearing loss, etiology, time of hearing deprivation, time of cochlear implant use and mean hearing threshold with the cochlear implant with the shift in speech coding strategy. There was no relationship between lack of handicap perception and improvement in speech perception in both speech coding strategies used. There was no significant difference between the strategies evaluated and no relation was observed between them and the variables studied.

  14. Authorship, collaboration, and funding trends in implantology literature: analysis of five journals from 2005 to 2009.

    PubMed

    Barão, Valentim Adelino Ricardo; Shyamsunder, Nodesh; Yuan, Judy Chia-Chun; Lee, Damian J; Assunção, Wirley Gonçalves; Sukotjo, Cortino

    2011-02-01

    To identify the trend of authorship in dental implant by exploring the prevalence of coauthored articles and to investigate the collaboration efforts, trends in funding involved in original articles, and their relationships. Articles published in the Clinical Oral Implants Research, International Journal of Oral & Maxillofacial Implants, Clinical Implant Dentistry and Related Research, Implant Dentistry, and Journal of Oral Implantology from 2005 to 2009 were reviewed. Nonoriginal articles were excluded. For each included articles, number of authors, collaboration efforts, and extramural funding were recorded. Descriptive and analytical statistics (α = 0.05), including logistic regression analysis and χ² test, were used. From a total of 2085 articles, 1503 met the inclusion criteria. Publications with 5 or more authors increased over time (P = 0.813). The amount of collaboration among different disciplines, institutions, and countries all increased. The greatest increase of collaboration was seen among institutions (P = 0.09). Nonfunding studies decreased over time (P = 0.031). There was a strong association between collaboration and funding for the manuscripts during the years studied (OR, 1.5). The number of authors per articles and collaborative studies increased over time in implant-related journals. Collaborative studies were more likely to be funded.

  15. Survival, Function, and Complications of Oral Implants Placed in Bone Flaps in Jaw Rehabilitation: A Systematic Review.

    PubMed

    Zhang, Lei; Ding, Qian; Liu, Cunrui; Sun, Yannan; Xie, Qiufei; Zhou, Yongsheng

    2016-01-01

    This systematic review attempted to determine the survival rate of implants placed in bone flaps in jaw rehabilitation and the functional gains and the most common complications related to these implants. An electronic search was undertaken of PubMed, EMBASE, and CNKI records from 1990 through July 2014. Two independent examiners read the titles and abstracts of the results to identify studies that met the inclusion criteria. Subsequently, the reference lists of the selected publications were hand searched. Descriptive statistics were used to report all data related to the survival rate of implants placed in bone flaps in jaw rehabilitation, the functional gains, and complications. A total of 20 studies were included for systematic review without repetition. The mean follow-up time after implant placement ranged from 1.75 to 9.5 years. Within the limitations of available studies, the survival rate of implants placed in bone flaps in jaw rehabilitation ranged from 82.4% to 100%. Of the 20 included studies, 15 reported a survival rate higher than 90%. The cumulative survival rate was 93.2%, with the longest follow-up time being 12.9 years. The most common complications related to these implants were peri-implant bone resorption or peri-implant inflammation, and peri-implant soft tissue proliferation. The main factors associated with the survival rate of implants in bone flaps were reported as time of implant placement and radiotherapy. Despite some persistent soft tissue problems and implant loss, most patients reached a satisfactory functional and esthetic outcome, as evaluated by clinical examination and subjectively by the patients at interview. Implant-supported dental prosthetic rehabilitation in reconstructed jaws improved the quality of life in terms of speech, nutrition, oral competence, and facial appearance. Placement of implants in bone flaps in jaw rehabilitation was demonstrated to be a reliable technique with a high survival rate. Multicentered randomized controlled clinical trials and longer clinical studies should be undertaken in this area.

  16. Comparison of Social Interaction between Cochlear-Implanted Children with Normal Intelligence Undergoing Auditory Verbal Therapy and Normal-Hearing Children: A Pilot Study.

    PubMed

    Monshizadeh, Leila; Vameghi, Roshanak; Sajedi, Firoozeh; Yadegari, Fariba; Hashemi, Seyed Basir; Kirchem, Petra; Kasbi, Fatemeh

    2018-04-01

    A cochlear implant is a device that helps hearing-impaired children by transmitting sound signals to the brain and helping them improve their speech, language, and social interaction. Although various studies have investigated the different aspects of speech perception and language acquisition in cochlear-implanted children, little is known about their social skills, particularly Persian-speaking cochlear-implanted children. Considering the growing number of cochlear implants being performed in Iran and the increasing importance of developing near-normal social skills as one of the ultimate goals of cochlear implantation, this study was performed to compare the social interaction between Iranian cochlear-implanted children who have undergone rehabilitation (auditory verbal therapy) after surgery and normal-hearing children. This descriptive-analytical study compared the social interaction level of 30 children with normal hearing and 30 with cochlear implants who were conveniently selected. The Raven test was administered to the both groups to ensure normal intelligence quotient. The social interaction status of both groups was evaluated using the Vineland Adaptive Behavior Scale, and statistical analysis was performed using Statistical Package for Social Sciences (SPSS) version 21. After controlling age as a covariate variable, no significant difference was observed between the social interaction scores of both the groups (p > 0.05). In addition, social interaction had no correlation with sex in either group. Cochlear implantation followed by auditory verbal rehabilitation helps children with sensorineural hearing loss to have normal social interactions, regardless of their sex.

  17. Periimplantitis.

    PubMed

    Sánchez-Gárces, María Angeles; Gay-Escoda, Cosme

    2004-01-01

    Orodental rehabilitation through the use of implants offers very high success rates. In this paper, we describe some of the complications involved with this technique, such as periimplant disease and, within this category, periimplantitis, an inflammatory reaction in which there is a loss of the bony support of the implant accompanied by inflammation. The aetiology of the disease is conditioned by the status of the tissue surrounding the implant, implant design, degree of roughness, the poor alignment of implant components, external morphology and excessive mechanical load. The microorganisms most commonly associated with implant failure are spirochetes and mobile forms of Gram-negative anaerobes, unless the origin is the result of simple mechanical overload. Diagnosis is based on changes of colour in the gum, bleeding and probing depth of periimplant pockets, suppuration, x-ray and gradual loss of bone height around the tooth. Treatment will differ depending upon whether it is a case of mucositis or periimplantitis. Therapeutic objectives focus on correcting technical defects by means of surgery and decontamination techniques (abrasion with carbon particles, citric acid solution, topical tetracycline application and laser surgery). This study also presents a microbiological study of periimplantitis conducted by the Barcelona School of Dentistry that determined that the antibiotic therapy proven to be most efficacious in the antibiogram was the association of amoxycillin and clavulanic acid.

  18. An Objective Estimation of Air-Bone-Gap in Cochlear Implant Recipients with Residual Hearing Using Electrocochleography.

    PubMed

    Koka, Kanthaiah; Saoji, Aniket A; Attias, Joseph; Litvak, Leonid M

    2017-01-01

    Although, cochlear implants (CI) traditionally have been used to treat individuals with bilateral profound sensorineural hearing loss, a recent trend is to implant individuals with residual low-frequency hearing. Notably, many of these individuals demonstrate an air-bone gap (ABG) in low-frequency, pure-tone thresholds following implantation. An ABG is the difference between audiometric thresholds measured using air conduction (AC) and bone conduction (BC) stimulation. Although, behavioral AC thresholds are straightforward to assess, BC thresholds can be difficult to measure in individuals with severe-to-profound hearing loss because of vibrotactile responses to high-level, low-frequency stimulation and the potential contribution of hearing in the contralateral ear. Because of these technical barriers to measuring behavioral BC thresholds in implanted patients with residual hearing, it would be helpful to have an objective method for determining ABG. This study evaluated an innovative technique for measuring electrocochleographic (ECochG) responses using the cochlear microphonic (CM) response to assess AC and BC thresholds in implanted patients with residual hearing. Results showed high correlations between CM thresholds and behavioral audiograms for AC and BC conditions, thereby demonstrating the feasibility of using ECochG as an objective tool for quantifying ABG in CI recipients.

  19. Dental implants modified with drug releasing titania nanotubes: therapeutic potential and developmental challenges.

    PubMed

    Gulati, Karan; Ivanovski, Sašo

    2017-08-01

    The transmucosal nature of dental implants presents a unique therapeutic challenge, requiring not only rapid establishment and subsequent maintenance of osseointegration, but also the formation of resilient soft tissue integration. Key challenges in achieving long-term success are sub-optimal bone integration in compromised bone conditions and impaired trans-mucosal tissue integration in the presence of a persistent oral microbial biofilm. These challenges can be targeted by employing a drug-releasing implant modification such as TiO 2 nanotubes (TNTs), engineered on titanium surfaces via electrochemical anodization. Areas covered: This review focuses on applications of TNT-based dental implants towards achieving optimal therapeutic efficacy. Firstly, the functions of TNT implants will be explored in terms of their influence on osseointegration, soft tissue integration and immunomodulation. Secondly, the developmental challenges associated with such implants are reviewed including sterilization, stability and toxicity. Expert opinion: The potential of TNTs is yet to be fully explored in the context of the complex oral environment, including appropriate modulation of alveolar bone healing, immune-inflammatory processes, and soft tissue responses. Besides long-term in vivo assessment under masticatory loading conditions, investigating drug-release profiles in vivo and addressing various technical challenges are required to bridge the gap between research and clinical dentistry.

  20. TIM Version 3.0 beta - Technical Description and User's Guidance

    EPA Pesticide Factsheets

    Provides technical information on version 3.0 of the Terrestrial Investigation Model (TIM v.3.0). Describes how TIM derives joint distributions of exposure and toxicity to calculate the risk of mortality to birds.

  1. 7 CFR 245.6 - Application, eligibility and certification of children for free and reduced price meals and free...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) General requirements—content of application and descriptive materials. Each local educational agency, as... to the distribution of applications and descriptive materials in paper form as provided for in this... requirements in this section and with technical assistance and guidance provided by FNS. Descriptive materials...

  2. 7 CFR 245.6 - Application, eligibility and certification of children for free and reduced price meals and free...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) General requirements—content of application and descriptive materials. Each local educational agency, as... to the distribution of applications and descriptive materials in paper form as provided for in this... requirements in this section and with technical assistance and guidance provided by FNS. Descriptive materials...

  3. Residential Energy Consumption Survey (RECS): Household screener survey, 1979-1980, household characteristics and annualized consumption

    NASA Astrophysics Data System (ADS)

    Windell, P.

    1981-08-01

    This document provides basic information and technical specifications necessary for using the machine-readable magnetic tape containing data from the Household Screener Survey of the Residential Energy Consumption Survey (RECS). Included in this document are an overview of the RECS and a brief description of the Household Screener Survey. The next section contains technical specifications for reading the tape and descriptions of the contents of each of the files contained on the tape. The remaining four sections are devoted to technical topics of special interest to users of the data. Appended to this document are copies of the fieldwork instruments used in the survey and a listing of the contents of a portion of the SPSS labels information.

  4. Scleral fixation of one piece intraocular lens by injector implantation

    PubMed Central

    Can, Ertuğrul; Başaran, Reşat; Gül, Adem; Birinci, Hakkı

    2014-01-01

    Aim of Study: With an ab-interno technique of transscleral suturing of current one-piece posterior chamber intraocular lenses (PC IOLs) by injector implantation in the absence of capsular support, we aimed to demonstrate the possibility of the implantation of one-piece acrylic PC IOLs that might be produced in the future for only scleral fixation through small clear corneal incision. Materials and Methods: Case report and literature review. Results: This procedure has been performed in eight aphakic eyes with four different types of IOLs. Good centration was achieved with minimal technical effort. All patients had well-centered and stable lenses postoperatively during 9-18 months follow-up. Conclusion: We managed to decrease the risks of surgical trauma and intricate surgical maneuvers requirement. With this technique, excessive fluid leakage and consecutive hypotony can be minimized. PMID:25230961

  5. Strategic Control Algorithm Development : Volume 2A. Technical Report.

    DOT National Transportation Integrated Search

    1974-08-01

    The technical report presents a detailed description of the strategic control functional objectives, followed by a presentation of the basic strategic control algorithm and how it evolved. Contained in this discussion are results of analyses that con...

  6. Strategic Control Algorithm Development : Volume 2B. Technical Report (Concluded)

    DOT National Transportation Integrated Search

    1974-08-01

    The technical report presents a detailed description of the strategic control functional objectives, followed by a presentation of the basic strategic control algorithm and how it evolved. Contained in this discussion are the results of analyses that...

  7. Special Feature: Teaching about High Tech.

    ERIC Educational Resources Information Center

    Kopf, Michael; And Others

    1992-01-01

    Includes four articles: "Virtual Reality" (Kopf), description of its uses in computer-assisted design, architecture, and technical training; "SME (Society of Manufacturing Engineers) Robotics Contest Opens Doors to Future" (Wagner); "Superconductivity" (Canady), description of classroom demonstrations and experiments;…

  8. Descriptive Chemistry in High School Curriculum.

    ERIC Educational Resources Information Center

    Rajan, Raj G.

    1983-01-01

    Discusses incorporation of descriptive chemistry and scientific/technical writing at the high school level. After discussing the periodic table, each student prepares a paper discussing the history, atomic data, occurring/extraction/purification, properties, and uses of an element. (JN)

  9. H-Coal Pilot Plant Phase II construction, Catlettsburg, Kentucky. Final construction management report, December 1976-February 1980. [February, 1977 to approximately January, 1980

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1983-03-01

    This report covers the H-Coal Pilot Plant facility located in Catlettsburg, Kentucky. The authorization for this project was under DOE contract No. DE-AC05-78ET11052, formally ET-78-C-01-3224. Badger Plants, Inc. carried out the construction management of this facility. The estimated total cost is $147,265,013. A brief process/technical description of the Pilot Plant covers subjects such as objectives, capacity, expected life, etc. A brief technical description of each processing unit, including its purpose in the overall operations of the plant is given. A general description of the organizational history of the project is given. Current overall organization and a description of the responsibilitiesmore » of each participant are included. Badger Plant's organization at manager level is shown.« less

  10. Remote monitoring of implantable cardioverter-defibrillators. Problems and implications using a telemonitoring system.

    PubMed

    Siebermair, J; Clauss, S; Martens, E; Schuessler, F; Oversohl, N; Haserueck, N; Estner, H L; Kääb, S; Wakili, R

    2015-04-01

    The rising number of implantable devices has led to an increase in device-related workload, e.g., regular interrogation follow-up visits. Telemonitoring systems for implantable cardioverter-defibrillators (ICDs) seem to be a promising tool for reducing workload and costs, and they have the potential of optimizing patient care. However, issues such as practical functionality of ICD telemonitoring in daily routine may affect its broad implementation. The objective of this study was to evaluate potential problems during the implementation of a telemonitoring system, Medtronic CareLink™ (CL™) with respect to the installation and data transmission process. A total of 159 patients with ICDs who were equipped with the CL™ system were evaluated and followed up for 16 months regarding the success rate of the first data transmission via the telemonitoring system. In this cohort, a high rate of nontransmission of 23.9 % was observed after the 16-month follow-up. A detailed interview of these patients (no transmission) revealed that the main reasons for failed transmissions were due to the patients' loss of interest in the concept (approximately 50 %) as well as technical problems (approximately 25 %) with setting up the system. These results indicate that telemonitoring systems bear potential problems and that the evaluation of patient motivation and technical support options seems to play an important role in establishing the functionality of these systems.

  11. Extended trochanteric osteotomy: current concepts review.

    PubMed

    Sambandam, Senthil Nathan; Duraisamy, Gopinath; Chandrasekharan, Jayadev; Mounasamy, Varatharaj

    2016-04-01

    Revision total hip arthroplasty is a technically demanding procedure which has gained importance for more than two decades. It was a nightmare for revision surgeons during its initial years of inception before the advent of extended trochanteric osteotomy (ETO). This technique gains access to the femoral medullary canal without compromising the bone stock and aids removal of primary implant and cement mantle without further damaging the parent bone. Like any other surgery, ETO does have certain limitations and complications as reported by various authors. Though it has been routinely used by revision surgeons, thorough knowledge of technical details of ETO is still lacking. So this review article is aimed at addressing the indications, surgical procedure, fixation technique, implant selection and complication of ETO which has been presented over a period of years by various authors. We searched in the most commonly used portals like MEDLINE (PubMed) and Google scholar using appropriate terminologies for the literature regarding the various preoperative, intraoperative and postoperative clinical scenarios in which revision surgeons utilized ETO. ETO is an important tool in the revision surgeon's armamentarium and can be used in variety of clinical scenarios and for various intraoperative needs and goals. Awareness about biomechanics of ETO, indications, implants selection, fixation techniques and complications is paramount for good intraoperative and postoperative outcome. ETO by posterior approach continues to be a work horse approach for most revision surgeons all over the world.

  12. Maxillary Four Implant-retained Overdentures via Locator® Attachment: Intermediate-term Results from a Retrospective Study.

    PubMed

    Wang, Feng; Monje, Alberto; Huang, Wei; Zhang, Zhiyong; Wang, Guomin; Wu, Yiqun

    2016-06-01

    Maxillary overdentures have been utilized to restore oral function in scenarios where limited bone structure represents a drawback for financial issues and for cases where oral hygiene is uncertain. The aim of this study was to evaluate the intermediate-term clinical outcome of four locator attachment retaining maxillary overdentures and to test their reliability. A retrospective study was conducted from January 2007 to October 2013. After the placement of four maxillary dental implants and a healing period of approximately 3 months, all the implants were restored with locator-retained overdentures with partial palatal coverage. Subjects and implant characteristics, implant position (anterior vs posterior maxilla), bone quality, and opposing dentition were recorded. Peri-implant clinical parameters and marginal bone loss (MBL) were evaluated after delivery of the final prosthesis and annually thereafter. The performance of locator components and the prosthetic restoration were also recorded at follow-up. A total of 104 implants were placed in 26 subjects (11 women, 15 men; mean age, 64 years; age range, 55-76 years). One implant failed before loading. One subject dropped out of the study during a mean follow-up period of 46 months (range: 7-73 months), achieving an overall survival rate of 95.2%. Clinical parameters revealed healthy tissues around most of the implants, with low scores of plaque and bleeding indices. At the last follow-up evaluation, the mean MBL was 1.7 ± 1.1 mm (0.4-2.6 mm). Regression model analysis indicated that MBL for implants in the posterior maxilla was significantly higher than that for implants in the anterior maxilla (p = .0487). Overall, 26 technical and prosthetic complications were reported. Within the limitations of this study, maxillary four implant-retained overdentures via Locator attachment seem to be a predictable alternative for oral rehabilitation. © 2015 Wiley Periodicals, Inc.

  13. 75 FR 52472 - Spectrum Requirements for Advanced Medical Technologies

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-26

    ... requires a ``Commission- approved human body simulator and test technique,'' fails to provide sufficient... therapeutic purposes in humans. In the MedRadio Order, the Commission also adopted service and technical rules... devices--the more flexible MedRadio rules accommodate body-worn as well as implanted medical devices...

  14. Evaluation Criteria of Noninvasive Telemonitoring for Patients With Heart Failure: Systematic Review.

    PubMed

    Farnia, Troskah; Jaulent, Marie-Christine; Steichen, Olivier

    2018-01-16

    Telemonitoring can improve heart failure (HF) management, but there is no standardized evaluation framework to comprehensively evaluate its impact. Our objectives were to list the criteria used in published evaluations of noninvasive HF telemonitoring projects, describe how they are used in the evaluation studies, and organize them into a consistent scheme. Articles published from January 1990 to August 2015 were obtained through MEDLINE, Web of Science, and EMBASE. Articles were eligible if they were original reports of a noninvasive HF telemonitoring evaluation study in the English language. Studies of implantable telemonitoring devices were excluded. Each selected article was screened to extract the description of the telemonitoring project and the evaluation process and criteria. A qualitative synthesis was performed. We identified and reviewed 128 articles leading to 52 evaluation criteria classified into 6 dimensions: clinical, economic, user perspective, educational, organizational, and technical. The clinical and economic impacts were evaluated in more than 70% of studies, whereas the educational, organizational, and technical impacts were studied in fewer than 15%. User perspective was the most frequently covered dimension in the development phase of telemonitoring projects, whereas clinical and economic impacts were the focus of later phases. Telemonitoring evaluation frameworks should cover all 6 dimensions appropriately distributed along the telemonitoring project lifecycle. Our next goal is to build such a comprehensive evaluation framework for telemonitoring and test it on an ongoing noninvasive HF telemonitoring project. ©Troskah Farnia, Marie-Christine Jaulent, Olivier Steichen. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 16.01.2018.

  15. A new universal, standardized implant database for product identification: a unique tool for arthroplasty registries.

    PubMed

    Blömer, Wilhelm; Steinbrück, Arnd; Schröder, Christian; Grothaus, Franz-Josef; Melsheimer, Oliver; Mannel, Henrich; Forkel, Gerhard; Eilers, Thomas; Liebs, Thoralf R; Hassenpflug, Joachim; Jansson, Volkmar

    2015-07-01

    Every joint registry aims to improve patient care by identifying implants that have an inferior performance. For this reason, each registry records the implant name that has been used in the individual patient. In most registries, a paper-based approach has been utilized for this purpose. However, in addition to being time-consuming, this approach does not account for the fact that failure patterns are not necessarily implant specific but can be associated with design features that are used in a number of implants. Therefore, we aimed to develop and evaluate an implant product library that allows both time saving barcode scanning on site in the hospital for the registration of the implant components and a detailed description of implant specifications. A task force consisting of representatives of the German Arthroplasty Registry, industry, and computer specialists agreed on a solution that allows barcode scanning of implant components and that also uses a detailed standardized classification describing arthroplasty components. The manufacturers classified all their components that are sold in Germany according to this classification. The implant database was analyzed regarding the completeness of components by algorithms and real-time data. The implant library could be set up successfully. At this point, the implant database includes more than 38,000 items, of which all were classified by the manufacturers according to the predefined scheme. Using patient data from the German Arthroplasty Registry, several errors in the database were detected, all of which were corrected by the respective implant manufacturers. The implant library that was developed for the German Arthroplasty Registry allows not only on-site barcode scanning for the registration of the implant components but also its classification tree allows a sophisticated analysis regarding implant characteristics, regardless of brand or manufacturer. The database is maintained by the implant manufacturers, thereby allowing registries to focus their resources on other areas of research. The database might represent a possible global model, which might encourage harmonization between joint replacement registries enabling comparisons between joint replacement registries.

  16. FY 1991 RDT&E Descriptive Summaries

    DTIC Science & Technology

    1990-01-01

    OF PROJECT : The Defense Sciences program element provides the technical foundation for long-term improvements in military equiment...DESCRIPTION OF PROJECT : Develop the fundamental technology in advanced digital structures and network concepts for smaller, more powerful, less expensive...DESCRIPTION OF PROJECT : The 1985 Defense Science Board (DSB) noted that the United States was behind and failing further behind in armor and

  17. Repositioning the Facilities in Technical College Workshops for Efficiency: A Case Study of North Central Nigeria

    ERIC Educational Resources Information Center

    Umar, Ibrahim Y.; Ma'aji, Abdullahi S.

    2010-01-01

    This article focuses on assessing the facilities in Government Technical College workshops in the context of a developing country. A descriptive survey design was adopted. Two research questions and a hypothesis were formulated to guide the study. A 35-item questionnaire was developed based on the National Board for Technical Education (NBTE)…

  18. Handbook of sensor technical characteristics

    NASA Astrophysics Data System (ADS)

    Tanner, S.

    1982-07-01

    Space and terrestrial applications remote sensor systems are described. Each sensor is presented separately. Information is included on its objectives, description, technical characteristics, data products obtained, data archives location, period of operation, and measurement and potential derived parameters. Each sensor is cross indexed.

  19. Solid Waste Program technical baseline description

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlson, A.B.

    1994-07-01

    The system engineering approach has been taken to describe the technical baseline under which the Solid Waste Program is currently operating. The document contains a mission analysis, function analysis, system definition, documentation requirements, facility and project bases, and uncertainties facing the program.

  20. 76 FR 50807 - Data Collection Available for Public Comments and Recommendations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-16

    ... development organizations (MDOs) to (1) Provide training and technical assistance to disadvantages and very... providing technical assistance to disadvantage and very-low income entrepreneurs. Information collected is... for Investment in Microentrepreneurs)''. Description of Respondents: Small Disadvantage Businesses...

  1. Handbook of sensor technical characteristics

    NASA Technical Reports Server (NTRS)

    Tanner, S.

    1982-01-01

    Space and terrestrial applications remote sensor systems are described. Each sensor is presented separately. Information is included on its objectives, description, technical characteristics, data products obtained, data archives location, period of operation, and measurement and potential derived parameters. Each sensor is cross indexed.

  2. The Extravehicular Mobility Unit (EMU): Proven hardware for Satellite Servicing

    NASA Technical Reports Server (NTRS)

    1982-01-01

    A general technical description of the extravehicular mobility unit (EMU) is given. The description provides a basis for understanding EMU mobility capabilities and the environments a payload is exposed to in the vicinity of an EMU.

  3. Cavernous Hemangioma Between the Elastomer and Fibrous Capsule of a Breast Implant.

    PubMed

    de Mello Tucunduva, Tatiana Cardoso; Gaziero, Antonio; Tostes, Vivian Siqueira; Stiepcich, Monica Maria Agata; Torres, Ulysses S; Ohara, Patricia; Andrade, Wesley Pereira; Ferreira, Adriana Helena Padovan Grassmann; Missrie, Debora Rejtman; de Mello, Giselle Guedes Netto

    2018-06-05

    Hemangiomas are described in many locations, but breast hemangioma (BH) is rare, accounting for only 0.4% of all breast tumors. These tumors are difficult to diagnose preoperatively using conventional imaging modalities because they lack pathognomonic characteristics. Mammographic and sonographic appearances of BH were described in just a few case reports, and breast implant-related hemangiomas are even rarer. We report a case of the tumor arising in an atypical location-between the elastomer and fibrous capsule of a breast implant.Level of Evidence V This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  4. [Use of an iliac branched endoprostheis in endovascular treatment for an abdominal aortic aneurysm combined with aneurysms of both common iliac arteries].

    PubMed

    Imaev, T E; Kuchin, I V; Lepilin, P M; Kolegaev, A S; Medvedeva, I S; Komlev, A E; Akchurin, R S

    An abdominal aortic aneurysm appears to be combined with aneurysmatic lesions of the common iliac arteries in 30-40% of cases. Like abdominal aortic aneurysms, aneurysms of the common iliac arteries rarely manifest themselves clinically. The lethality rate in case of rupture is comparable to that for rupture of an abdominal aortic aneurysm. During endoprosthetic repair of abdominal aortic aneurysms combined with aneurysms of the common iliac arteries, in order to prevent endoleaks and to improve the distal zone of fixation of endografts surgeons often resort to embolization of internal iliac arteries, which may lead to ischaemic postoperative complications. One of the methods of preserving pelvic blood flow is the use of an iliac branched endograft. A series of studies evaluating long-term outcomes demonstrated that this method proved to be both safe and effective, and with the suitable anatomy is a method of choice in high surgical risk patients. The present article deals with a clinical case report concerning bilateral endoprosthetic repair of the common iliac arteries, combined with endoprosthetic repair of an abdominal aortic aneurysm, with the description of technical peculiarities of implanting an iliac branched graft.

  5. Patient selection for transcatheter aortic valve replacement: A combined clinical and multimodality imaging approach

    PubMed Central

    Cocchia, Rosangela; D’Andrea, Antonello; Conte, Marianna; Cavallaro, Massimo; Riegler, Lucia; Citro, Rodolfo; Sirignano, Cesare; Imbriaco, Massimo; Cappelli, Maurizio; Gregorio, Giovanni; Calabrò, Raffaele; Bossone, Eduardo

    2017-01-01

    Transcatheter aortic valve replacement (TAVR) has been validated as a new therapy for patients affected by severe symptomatic aortic stenosis who are not eligible for surgical intervention because of major contraindication or high operative risk. Patient selection for TAVR should be based not only on accurate assessment of aortic stenosis morphology, but also on several clinical and functional data. Multi-Imaging modalities should be preferred for assessing the anatomy and the dimensions of the aortic valve and annulus before TAVR. Ultrasounds represent the first line tool in evaluation of this patients giving detailed anatomic description of aortic valve complex and allowing estimating with enough reliability the hemodynamic entity of valvular stenosis. Angiography should be used to assess coronary involvement and plan a revascularization strategy before the implant. Multislice computed tomography play a central role as it can give anatomical details in order to choice the best fitting prosthesis, evaluate the morphology of the access path and detect other relevant comorbidities. Cardiovascular magnetic resonance and positron emission tomography are emergent modality helpful in aortic stenosis evaluation. The aim of this review is to give an overview on TAVR clinical and technical aspects essential for adequate selection. PMID:28400918

  6. Endovascular Treatment of Severely Calcified Femoropopliteal Lesions Using the "Pave-and-Crack" Technique: Technical Description and 12-Month Results.

    PubMed

    Dias-Neto, Marina; Matschuck, Manuela; Bausback, Yvonne; Banning-Eichenseher, Ursula; Steiner, Sabine; Branzan, Daniela; Staab, Holger; Varcoe, Ramon L; Scheinert, Dierk; Schmidt, Andrej

    2018-06-01

    To report midterm results of the "pave-and-crack" technique to facilitate safe and effective scaffolding of heavily calcified femoropopliteal lesions in preparation for delivery of a Supera interwoven stent. Data were collected retrospectively on 67 consecutive patients (mean age 71±8 years; 54 men) treated with this technique between November 2011 and February 2017 at a single center. A third (22/64, 34%) of the patients had critical limb ischemia (CLI). Most lesions were TASC D (52/67, 78%), and the majority were occlusions (61/66, 92%). The mean lesion length was 26.9±11.2 cm. Nearly two-thirds (40/64, 62%) had grade 4 calcification (Peripheral Arterial Calcium Scoring System). To prepare for Supera stenting, the most heavily calcified segments of the lesion were predilated aggressively to obliterate recoil. A Viabahn stent-graft was then implanted to "pave" the lesion and protect from vessel rupture as aggressive predilation continued until the calcified plaque was "cracked" before lining the entire lesion with a Supera stent. Patency and target lesion revascularization (TLR) rates were estimated using the Kaplan-Meier method. Procedural success was achieved in 100% and technical success (residual stenosis <30%) in 98% (66/67). The mean cumulative stent lengths were 16±9 cm for the Viabahn and 23±12 cm for the Supera. Only 2 complications occurred (distal embolization and access-site pseudoaneurysm). Two CLI patients died within 30 days, and 3 patients (all claudicants) underwent a TLR. Patients were followed for a mean 19±18 months, during which another 2 CLI patients died and 1 patient had a major amputation. One-year primary and secondary patency estimates were 79% and 91%, respectively; freedom from TLR was 85%. Despite severe lesion calcification, patients experienced high technical success and a safe and durable therapy at midterm follow-up with the femoropopliteal "pave-and-crack" technique.

  7. Unrecoverable bi-products of drilling titanium alloy and tantalum metal implants: a pilot study.

    PubMed

    Skowronek, Paweł; Olszewski, Paweł; Święszkowski, Wojciech; Synder, Marek; Sibiński, Marcin; Mazek, Jacek

    2018-05-01

    Trabecular metal implants with a porous architecture that allows for the incorporation of bone into the implant during healing are gaining popularity in alloplastic revision procedures. The bi-products of drilling titanium alloy (Ti) and tantalum (Ta) implants have not been previously assessed. Four holes were drilled in each of two spatially porous trabecular implants, one Ta and the other Ti alloy (Ti-6Al-7Nb), for this pilot in vitro study. The particles were flushed out with a continuous flow of saline. The particles' weight and the volume were then measured using a Radwag XA 110/2X (USA) laboratory balance. The total volume of the obtained metal fines was measured by titration using a 10 mm 3 measurement system. A cobalt carbide bit was used since the holes could not be made with a standard bone drill. Each Ti and Ta implant lost 1.26 g and 2.48 g of mass, respectively. The volume of free particles recovered after each stage was 280 mm 3 and 149 mm 3 , respectively. Approximately 0.6% of the total implant mass was not recovered after drilling (roughly 2% of the mass of the particles created by drilling), despite the use of 5 µm filters. It is technically difficult to drill holes in Ti and Ta implants using standard surgical tools. The drilling process creates a considerable amount of metal particles, which cannot be recovered despite intensive flushing. This may have an adverse influence on the bio-functionality (survival) of the endoprosthesis and present deleterious systemic consequences.

  8. Effect of titanium dental implants on proton therapy delivered for head tumors: experimental validation using an anthropomorphic head phantom

    NASA Astrophysics Data System (ADS)

    Oancea, C.; Shipulin, K.; Mytsin, G.; Molokanov, A.; Niculae, D.; Ambrožová, I.; Davídková, M.

    2017-03-01

    A dosimetric experiment was performed at the Medico-Technical Complex in the Joint Institute for Nuclear Research, Dubna, to investigate the effects of metallic dental implants in the treatment of head and neck tumours with proton therapy. The goal of the study was to evaluate the 2D dose distributions of different clinical treatment plans measured in an anthropomorphic phantom, and compare them to predictions from a treatment planning system. The anthropomorphic phantom was sliced into horizontal segments. Two grade 4 Titanium implants were inserted between 2 slices, corresponding to a maxillary area. GafChromic EBT2 films were placed between the segments containing the implants to measure the 2D delivered dose. Two different targets were designed: the first target includes the dental implants in the isocentre, and in the second target, the proton beam is delivered through the implants, which are located at the entrance region of the Bragg curve. The experimental results were compared to the treatment plans made using our custom 3D Treatment Planning System, named RayTreat. To quantitatively determine differences in the isodose distributions (measured and calculated), the gamma index (3 mm, 3%) was calculated for each target for the matrix value in the region of high isodose (> 90%): for the experimental setup, which includes the implants in the SOBP region, the result obtained was 84.3%. When the implants were localised in the entrance region of the Bragg curve, the result obtained was 86.4%. In conclusion, the uncertainties introduced by the clinically planned dose distribution are beyond reasonable limits. The linear energy transfer spectra in close proximity to the implants were investigated using solid state nuclear track detectors (TED). Scattered particles outside the target were detected.

  9. Three-Year Outcome of Fixed Partial Rehabilitations Supported by Implants Inserted with Flap or Flapless Surgical Techniques.

    PubMed

    Maló, Paulo; de Araújo Nobre, Miguel; Lopes, Armando

    2016-07-01

    The aim of this prospective clinical study was to evaluate the 3-year outcome of fixed partial prostheses supported by implants with immediate provisionalization without occlusal contacts inserted in predominantly soft bone with flap and flapless protocols. Forty-one patients partially rehabilitated with 72 NobelSpeedy implants (51 maxillary; 21 mandibular) were consecutively included and treated with a flapless surgical protocol (n = 20 patients; 32 implants) and flapped surgical protocol (n = 21 patients; 40 implants). Primary outcome measure was implant survival; secondary outcome measures were marginal bone resorption (comparing the bone levels at 1 and 3 years with baseline) and the incidence of biological, mechanical, and esthetic complications. Survival was computed through life tables; descriptive statistics were applied to the remaining variables of interest. Eight patients with eight implants dropped out of the study. One implant failed in one patient (flapless group) giving an overall cumulative survival rate (CSR) of 98.6%. No failures were noted with the flapped protocol (CSR 100%), while for the implants placed with the flapless surgical technique, a 96.9% CSR was registered. The overall average marginal bone resorption at 3 years was 1.37 mm (SD = 0.94 mm), with 1.14 mm (SD = 0.49 mm) and 1.60 mm (SD = 1.22 mm) for the flap and flapless groups, respectively. Mechanical complications occurred in nine patients (n = 5 patients in the flapless group; n = 4 patients in the flap group). Implant infection was registered in three implants and three patients (flapless group), who exhibited inadequate oral hygiene levels. Partial edentulism rehabilitation through immediate provisionalization fixed prosthesis supported by dental implants inserted through flap or flapless surgical techniques in areas of predominantly soft bone was viable at 3 years of follow-up. The limitations and risks of the "free-hand" method in flapless surgery should be considered when planning implant-supported fixed prosthetic reconstructions. © 2015 by the American College of Prosthodontists.

  10. ENUCLEATION IN MALIGNANT CHOROIDAL MELANOMA - results in 15 years of using a new material in the prosthesis of the orbital cavity

    PubMed Central

    Tataru, CP; Pop, MD

    2012-01-01

    Rationale: Enucleation implants are covered with a material that allows the fixation of the extraocular rectus muscles. Usually, the implants are covered in donor sclera, which implies the risk of infection transmission, inflammation and implant rejection, being also an expensive procedure. The new materials used for implant meshing should be tested and a safer and cost effective solution should be researched. Objective: This study presents the results obtained after a 15-year use of an original prosthesis for the reconstruction of the orbital cavity after enucleation surgery. Methods and results: 42 eyes of 42 patients who underwent enucleation surgery for choroidal malignant melanoma were included in the study. The surgical technique was very similar to the classic enucleation, the major difference being the implant of a prosthesis made out of a Polymethyl methacrylate (PMMA) ball covered by a Polyethylene terephthalate (dacron) shell used in cardiovascular surgery. All the patients had a very good technical result, without the inflammation of the orbital cavity, conjunctiva or eyelids, which demonstrates a very high material tolerability and an excellent cosmetic result. Late implant expulsion appeared in 7.14% of the patients (3 cases). Discussion: The particularly good results obtained by using this technique, the absence of an inflammatory reaction after surgery, and the long lasting stability of the implant, recommend the method as being safe, with no major complications and a good esthetic result. AbbreviationsPolymethyl methacrylate (PMMA), Malignant choroidal melanoma (CMM) PMID:22802888

  11. Minimally Invasive Epicardial Pacemaker Implantation in Neonates with Congenital Heart Block.

    PubMed

    Costa, Roberto; Silva, Katia Regina da; Martinelli Filho, Martino; Carrillo, Roger

    2017-10-01

    Few studies have characterized the surgical outcomes following epicardial pacemaker implantation in neonates with congenital complete atrioventricular block (CCAVB). This study sought to assess the long-term outcomes of a minimally invasive epicardial approach using a subxiphoid access for pacemaker implantation in neonates. Between July 2002 and February 2015, 16 consecutive neonates underwent epicardial pacemaker implantation due to CCAVB. Among these, 12 (75.0%) had congenital heart defects associated with CCAVB. The patients had a mean age of 4.7 ± 5.3 days and nine (56.3%) were female. Bipolar steroid-eluting epicardial leads were implanted in all patients through a minimally invasive subxiphoid approach and fixed on the diaphragmatic ventricular surface. The pulse generator was placed in an epigastric submuscular position. All procedures were successful, with no perioperative complications or early deaths. Mean operating time was 90.2 ± 16.8 minutes. None of the patients displayed pacing or sensing dysfunction, and all parameters remained stable throughout the follow-up period of 4.1 ± 3.9 years. Three children underwent pulse generator replacement due to normal battery depletion at 4.0, 7.2, and 9.0 years of age without the need of ventricular lead replacement. There were two deaths at 12 and 325 days after pacemaker implantation due to bleeding from thrombolytic use and progressive refractory heart failure, respectively. Epicardial pacemaker implantation through a subxiphoid approach in neonates with CCAVB is technically feasible and associated with excellent surgical outcomes and pacing lead longevity.

  12. Computer-Guided Implant Surgery in Fresh Extraction Sockets and Immediate Loading of a Full Arch Restoration: A 2-Year Follow-Up Study of 14 Consecutively Treated Patients

    PubMed Central

    Daas, M.; Assaf, A.; Dada, K.; Makzoumé, J.

    2015-01-01

    Statement of Problem. Low scientific evidence is identified in the literature for combining implant placement in fresh extraction sockets with immediate function. Moreover, the few studies available on immediate implants in postextraction sites supporting immediate full-arch rehabilitation clearly lack comprehensive protocols. Purpose. The purpose of this study is to report outcomes of a comprehensive protocol using CAD-CAM technology for surgical planning and fabrication of a surgical template and to demonstrate that immediate function can be easily performed with immediate implants in postextraction sites supporting full-arch rehabilitation. Material and Methods. 14 subjects were consecutively rehabilitated (13 maxillae and 1 mandible) with 99 implants supporting full-arch fixed prostheses followed between 6 and 24 months (mean of 16 months). Outcome measures were prosthesis and implant success, biologic and prosthetic complications, pain, oedema evaluation, and radiographic marginal bone levels at surgery and then at 6, 12, 18, and 24 months. Data were analyzed with descriptive statistics. Results. The overall cumulative implant survival rate at mean follow-up time of 16 months was 97.97%. The average marginal bone loss was 0,9 mm. Conclusions. Within the limitations of this study, the results validate this treatment modality for full-arch rehabilitations with predictable outcomes and high survival rate after 2 years. PMID:26064119

  13. Stress-strain analysis of porous scaffolds made from titanium alloys synthesized via SLS method

    NASA Astrophysics Data System (ADS)

    Shishkovsky, I.

    2009-09-01

    A layer-by-layer selective laser sintering (SLS) technology seems to be greatly promising for solving the plastic surgery problems, particularly those pertaining to the facial reconstruction. Made from titanium-based alloys (titanium or nitinol, i.e. NiTi-intermetallic phase), the porous scaffolds for cranioplasty are an efficient tool for rectifying the face defects and for the dental orthopedic surgery. The progress in the oral surgery and teeth implantation is caused by the problem of an osteointegration on the one hand, and by achievements of the implant synthesis techniques, on the other hand. An important problem thereby is a profound study of the stress-strain behavior of porous implants under the masticatory load or pressure. In the present study the ways for the optimization of the porous implant structural and strength properties as the function of the laser synthesis parameters are described. The finite element approach (ANSYS) was used here for a complex dowel description and numerical simulations. In order to evaluate the processes in the porous implant under the external loading, a CAD 3D model was built for different internal and external configurations of the implant and/or initial shape of powdered particles. The stress-strain dependences were calculated that displayed the irregularity of the stress distribution by the implant volume in the bone tissue. Most of the values are concentrated in places of object contact.

  14. Volumetric Analysis of Gingival Crevicular Fluid and Peri-Implant Sulcus Fluid in Healthy and Diseased Sites: A Cross-Sectional Split-Mouth Pilot Study

    PubMed Central

    Bevilacqua, Lorenzo; De Biasi, Matteo; Lorenzon, Maria Giulia; Frattini, Costanza; Angerame, Daniele

    2016-01-01

    Background: Researchers have recently drawn attention to the analysis of gingival crevicular fluid (GCF) and peri-implant sulcus fluid (PISF) for the implementation of the diagnosis of periodontal and peri-implant disease. Nevertheless, the measurements of volume and biomarkers concentration can be critically biased when data collected from studies with parallel group design are compared, given the technical difficulties, methodological variables, as well as the variability of crevicular fluid characteristics among different individuals. Objective: The aim of the present study was to assess the GCF and PISF volumes in healthy and diseased sites belonging to the same patient. Method: Ten patients presenting a periodontally healthy tooth, a tooth with periodontitis, an implant with healthy peri-implant tissues and an implant with peri-implantitis were enrolled. Samples of GCF and PISF were collected from each site of interest and their volume measured with a Periotron 8000 device. Non-parametric statistical analysis was performed to test the significance of the differences in GCF and PISF volumes between i) sites of teeth and dental implants with the same condition of health or disease and ii) healthy and diseased sites of both teeth and dental implants subgroups. The correlation between probing pocket depth (PPD) and fluid production was also tested (p<0.05). Results: Healthy periodontal and peri-implant tissues produced comparable amounts of fluid that was significantly lower than in diseased sites (p<0.05). In the presence of diagnosed disease, the volumes of GCF and PISF were similar, too. The correlation between PPD and fluid production was significant only in healthy sites (PPD/GCF, ρ=0.890, p<0.001; PPD/PISF, ρ=0.810; p<0.005). Conclusion: The periodontal and peri-implant tissues behaved similarly in terms of fluid production in condition of both health and active disease. PMID:27335614

  15. The NASA scientific and technical information system: Its scope and coverage

    NASA Technical Reports Server (NTRS)

    1988-01-01

    A general description of the subject areas covered in the NASA scientific and technical information system is presented. In addition, it establishes subject-based selection criteria for guiding decisions related to the addition of new documents to the NASA collection.

  16. The Evolution of Image-Free Robotic Assistance in Unicompartmental Knee Arthroplasty.

    PubMed

    Lonner, Jess H; Moretti, Vincent M

    2016-01-01

    Semiautonomous robotic technology has been introduced to optimize accuracy of bone preparation, implant positioning, and soft tissue balance in unicompartmental knee arthroplasty (UKA), with the expectation that there will be a resultant improvement in implant durability and survivorship. Currently, roughly one-fifth of UKAs in the US are being performed with robotic assistance, and it is anticipated that there will be substantial growth in market penetration of robotics over the next decade. First-generation robotic technology improved substantially implant position compared to conventional methods; however, high capital costs, uncertainty regarding the value of advanced technologies, and the need for preoperative computed tomography (CT) scans were barriers to broader adoption. Newer image-free semiautonomous robotic technology optimizes both implant position and soft tissue balance, without the need for preoperative CT scans and with pricing and portability that make it suitable for use in an ambulatory surgery center setting, where approximately 40% of these systems are currently being utilized. This article will review the robotic experience for UKA, including rationale, system descriptions, and outcomes.

  17. Histologic and Radiographic Analysis of Nonhealing Extraction Sockets Treated with Bio-Oss Collagen After a 4-Month Healing Period: A Prospective Descriptive Study in Humans.

    PubMed

    Tirone, Federico; Salzano, Stefano; Pagano, Marco

    2018-03-07

    Healing of extraction sockets may sometimes result in formation of fibrous tissue instead of bone, even after 4 months, an occurrence that may hinder implant placement. The aim of this preliminary observational study was to histologically evaluate quality and amount of bone regeneration after treating nonhealing sockets with a bovine-derived xenograft enriched with porcine collagen (Bio-Oss Collagen, Geistlich) without barrier membranes. Biopsy specimens were collected during implant placement, 4 months after grafting. A total of 10 cases were treated and evaluated. In all cases, correct implant placement was possible and no implant failure occurred up to 6 months after loading. The histologic analysis demonstrated new bone formation in all specimens. The percentage of newly formed bone was 29.1% (SD 20.71%; range 5% to 48%). Xenograft particles in direct contact with newly formed bone were visible, and mature lamellar bone was observed in 8 cases.

  18. A survey of the satisfaction of patients who have undergone implant surgery with and without employing a computer-guided implant surgical template

    PubMed Central

    Youk, Shin-Young; Lee, Jee-Ho; Heo, Seong-Joo; Roh, Hyun-Ki; Park, Eun-Jin; Shin, Im Hee

    2014-01-01

    PURPOSE This study aims to investigate the degree of subjective pain and the satisfaction of patients who have undergone an implant treatment using a computer-guided template. MATERIALS AND METHODS A survey was conducted for 135 patients who have undergone implant surgery with and without the use of the computer-guided template during the period of 2012 and 2013 in university hospitals, dental hospitals and dental clinics that practiced implant surgery using the computer-guided template. Likert scale and VAS score were used in the survey questions, and the independent t-test and One-Way ANOVA were performed (α=.05). RESULTS The route that the subjects were introduced to the computer-guided implant surgery using a surgical template was mostly advices by dentists, and the most common reason for which they chose to undergo such surgery was that it was accurate and safe. Most of them gave an answer that they were willing to recommend it to others. The patients who have undergone the computer-guided implant surgery felt less pain during the operation and showed higher satisfaction than those who have undergone conventional implant surgery. Among the patients who have undergone computer-guided implant surgery, those who also had prior experience of surgery without a computer-guided template expressed higher satisfaction with the former (P<.05). CONCLUSION In this study, it could be seen that the patients who have undergone computer-guided implant surgery employing a surgical template felt less pain and had higher satisfaction than those with the conventional one, and the dentist's description could provide the confidence about the safety of surgery. PMID:25352962

  19. EAO Supplement Working Group 4 - EAO CC 2015 Short implants versus sinus lifting with longer implants to restore the posterior maxilla: a systematic review.

    PubMed

    Thoma, D S; Zeltner, M; Hüsler, J; Hämmerle, C H F; Jung, R E

    2015-09-01

    To compare short implants in the posterior maxilla to longer implants placed after or simultaneously with sinus floor elevation procedures. The focused question was as follows: Are short implants superior to longer implants in the augmented sinus in terms of survival and complication rates of implants and reconstructions, patient-reported outcome measures (PROMs) and costs? A MEDLINE search (1990-2014) was performed for randomized controlled clinical studies comparing short implants (≤8 mm) to longer implants (>8 mm) in augmented sinus. The search was complimented by an additional hand search of the selected papers and reviews published between 2011 and 2014. Eligible studies were selected based on the inclusion criteria, and quality assessments were conducted. Descriptive statistics were applied for a number of outcome measures. Survival rates of dental implants were pooled simply in case of comparable studies. Eight randomized controlled clinical trials (RCTs) comparing short implants versus longer implants in the augmented sinus derived from an initial search count of 851 titles were selected and data extracted. In general, all studies were well conducted with a low risk of bias for the majority of the analyzed parameters. Based on the pooled analyses of longer follow-ups (5 studies, 16-18 months), the survival rate of longer implants amounted to 99.5% (95% CI: 97.6-99.98%) and for shorter implants to 99.0% (95% CI: 96.4-99.8%). For shorter follow-ups (3 studies, 8-9 months), the survival rates of longer implants are 100% (95% CI: 97.1-100%) and for shorter implants 98.2% (95% CI: 93.9-99.7%). Complications were predominantly of biological origin, mainly occurred intraoperatively as membrane perforations, and were almost three times as higher for longer implant in the augmented sinus compared to shorter implants. PROMs, morbidity, surgical time and costs were generally in favor of shorter dental implants. All studies were performed by surgeons in specialized clinical settings. The outcomes of the survey analyses demonstrated predictably high implant survival rates for short implants and longer implants placed in augmented sinus and their respective reconstructions. Given the higher number of biological complications, increased morbidity, costs and surgical time of longer dental implants in the augmented sinus, shorter dental implants may represent the preferred treatment alternative. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Monitored Geologic Repository Project Description Document

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    P. M. Curry

    2001-01-30

    The primary objective of the Monitored Geologic Repository Project Description Document (PDD) is to allocate the functions, requirements, and assumptions to the systems at Level 5 of the Civilian Radioactive Waste Management System (CRWMS) architecture identified in Section 4. It provides traceability of the requirements to those contained in Section 3 of the ''Monitored Geologic Repository Requirements Document'' (MGR RD) (YMP 2000a) and other higher-level requirements documents. In addition, the PDD allocates design related assumptions to work products of non-design organizations. The document provides Monitored Geologic Repository (MGR) technical requirements in support of design and performance assessment in preparing formore » the Site Recommendation (SR) and License Application (LA) milestones. The technical requirements documented in the PDD are to be captured in the System Description Documents (SDDs) which address each of the systems at Level 5 of the CRWMS architecture. The design engineers obtain the technical requirements from the SDDs and by reference from the SDDs to the PDD. The design organizations and other organizations will obtain design related assumptions directly from the PDD. These organizations may establish additional assumptions for their individual activities, but such assumptions are not to conflict with the assumptions in the PDD. The PDD will serve as the primary link between the technical requirements captured in the SDDs and the design requirements captured in US Department of Energy (DOE) documents. The approved PDD is placed under Level 3 baseline control by the CRWMS Management and Operating Contractor (M and O) and the following portions of the PDD constitute the Technical Design Baseline for the MGR: the design characteristics listed in Table 1-1, the MGR Architecture (Section 4.1), the Technical Requirements (Section 5), and the Controlled Project Assumptions (Section 6).« less

  1. [Osteosynthesis-associated infections : Epidemiology, definition and diagnosis].

    PubMed

    Renz, N; Feihl, S; Dlaska, C E; Schütz, M A; Trampuz, A

    2017-06-01

    Osteosynthesis-associated infections occur in 1-5% after closed and in up to 30% after open fractures. There are three different descriptions of implant-associated infections after fracture fixation, which are crucial for the selection of the adequate treatment strategy; temporal appearance from the index surgery (early versus late), pathogenesis of the infection (exogenous, hematogenous and contiguous from an adjacent focus), duration of infection symptoms (acute versus chronic). Diagnosis of osteosynthesis-associated infection is challenging, as chronic low-grade infections often present only with unspecific and subtle clinical symptoms. History, clinical evaluation, imaging, histopathlogical and microbiological examination build the cornerstones of diagnostics in implant-associated infections. A new onset of rest pain, early loosening of the prosthesis or mechanically unexplained, nonunion should raise suspicion for infection and prompt further evaluation. Percutaneous sinus tracts, purulent wound secretion and skin erosions with visibility of the implant confirm the implant-associated infection. Elevated C‑reactive protein value in blood is a supportive argument for infection, but is neither sensitive nor specific for infection. Imaging plays a key role to detect nonunions, infectious callus, sequester, peri-implant osteolysis and extraosseous and intramedullary involvement. Through microbiological and histopathological examination of intraoperative tissue samples, as well as sonication of explanted implants the causative pathogen is identified in most cases.

  2. Clinical guideline on bone conduction implants.

    PubMed

    Lavilla Martín de Valmaseda, María José; Cavalle Garrido, Laura; Huarte Irujo, Alicia; Núñez Batalla, Faustino; Manrique Rodriguez, Manuel; Ramos Macías, Ángel; de Paula Vernetta, Carlos; Gil-Carcedo Sañudo, Elisa; Lassaleta, Luis; Sánchez-Cuadrado, Isabel; Espinosa Sánchez, Juan Manuel; Batuecas Caletrio, Ángel; Cenjor Español, Carlos

    2018-04-13

    During the last decade there have been multiple and relevant advances in conduction and mixed hearing loss treatment. These advances and the appearance of new devices have extended the indications for bone-conduction implants. The Scientific Committee of Audiology of the Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello SEORL-CCC (Spanish Society of Otolaryngology and Head and Neck Surgery), together with the Otology and Otoneurology Committees, have undertaken a review of the current state of bone-conduction devices with updated information, to provide a clinical guideline on bone-conduction implants for otorhinolaryngology specialists, health professionals, health authorities and society in general. This clinical guideline on bone-conduction implants contains information on the following: 1) Definition and description of bone-conduction devices; 2) Current and upcoming indications for bone conduction devices: Magnetic resonance compatibility; 3) Organization requirements for a bone-conduction implant programme. The purpose of this guideline is to describe the different bone-conduction implants, their characteristics and their indications, and to provide coordinated instructions for all the above-mentioned agents for decision making within their specific work areas. Copyright © 2018 Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Endochondral vs. intramembranous demineralized bone matrices as implants for osseous defects.

    PubMed

    Nidoli, M C; Nielsen, F F; Melsen, B

    1999-05-01

    This study focuses on the difference in regenerative capacity between endochondral and intramembranous demineralized bone matrices (DBMs) when implanted into bony defects. It also focuses on the possible influence of the type of skeletal recipient site (orthotopic or heterotopic). Of 34 Wistar rats, 10 served as a source of DBM, and 24 were divided into two groups of 12 animals. In group A identical defects were produced in the parietal bones, whereas in group B the defects were produced in each radius. The right defects were implanted with endochondral DBM and the left defects were implanted with intramembranous DBM. Descriptive and/or histomorphometric analyses were performed by means of light and polarized microscopy, and radiography (group B). Right and left data were compared to disclose differences in bone-healing capacity. The quantitative results demonstrated that endochondral DBM displays a greater regenerative capacity than intramembranous DBM when implanted heterotopically. The different clinical performances of endochondral and intramembranous bone grafts might be explained on the basis of the mechanical rather than the osteoinductive principle. The qualitative results suggest that the type of bone deposition induced by the DBMs is not related to the type of implanted DBM. Recipient site characteristics and/or environmental factors seem decisive in the occurrence of either types of ossification.

  4. Technical survey of the French role in multichannel cochlear implant development.

    PubMed

    Chouard, Claude-Henri

    2015-06-01

    The objective of this review is to remind the ENT community of the essential role of the French teams in the development and finalization of the multi-electrode cochlear implant (MCI), which has deliberately been neglected, and to repair the oblivion into which France was curiously cast at the end of the last century. It aims to underline significant scientific publications from the researchers who played key roles in the development of MCIs. In conclusion, the Parisian team of the ENT Lab in Saint Antoine Hospital in Paris can claim priority for its work in five regards. We were the first: (1) to plot in 1976 a frequency map of the whole length of three living human cochleas; (2) on September 22, 1976, to set up total cochlear implantation in a deaf adult male with eight electrodes; (3) on March 16, 1977, to apply for a patent for an implantable hearing aid in humans; (4) to describe sound signal processing (SSP) for a functional cochlear implant able to supply totally deaf patients with speech discrimination without the help of lip-reading; (5) in 1983, to experimentally demonstrate why it was necessary to place a cochlear implant as early as possible, in case of profound neonatal deafness. An injustice has occurred. These facts will be brought to the knowledge of the scientific community.

  5. Temporary implant-supported prosthesis for immediate loading according to a chair-side concept: technical note and results from 37 consecutive cases.

    PubMed

    Ostman, Pär-Olov; Hellman, Mats; Sennerby, Lars; Wennerberg, Ann

    2008-05-01

    During the last years, focus has been paid to implant treatment using immediate function protocols, and different approaches to provide patients with temporary constructions have been presented. Most of these techniques involve dental technicians producing the temporary construction, for example, rebuilding existing dentures, acrylic bridges, etc. The purpose of this prospective clinical study was to evaluate the clinical outcome of a chair-side technique of a cost-effective temporary prosthesis. Fixture survival rate and risk of temporary bridge failure were analyzed. Thirty-seven partially or totally edentate patients (18 female and 19 male; mean age: 66.7 years) treated with chair-side manufactured temporary restorations (QuickBridge, BIOMET 3i, Palm Beach, Fl, USA) for immediate loading have been evaluated. The prostheses extended from two unit bridges supported by two implants to full-arch construction supported by six implants. The temporary prostheses were monitored from the day of surgery and delivery to the time of replacement with a permanent prosthetic construction 3 to 6 months later. No implants were lost during the observation time. One (3%) temporary prosthesis fractured and additional two (6%) loosened during the follow-up time. The study indicated that the tested chair-side concept for manufacturing of temporary prosthesis for immediate loading of dental implants is a viable approach.

  6. Return of the cadaver

    PubMed Central

    Krähenbühl, Swenn Maxence; Čvančara, Paul; Stieglitz, Thomas; Bonvin, Raphaël; Michetti, Murielle; Flahaut, Marjorie; Durand, Sébastien; Deghayli, Lina; Applegate, Lee Ann; Raffoul, Wassim

    2017-01-01

    Abstract Successful Plastic Surgery Residency training is subjected to evolving society pressure of lower hourly work weeks imposed by external committees, labor laws, and increased public awareness of patient care quality. Although innovative measures for simulation training of surgery are appearing, there is also the realization that basic anatomy training should be re-enforced and cadaver dissection is of utmost importance for surgical techniques. In the development of new technology for implantable neurostimulatory electrodes for the management of phantom limb pain in amputee patients, a design of a cadaveric model has been developed with detailed steps for innovative transfascicular insertion of electrodes. Overall design for electrode and cable implantation transcutaneous was established and an operating protocol devised. Microsurgery of the nerves of the upper extremities for interfascicular electrode implantation is described for the first time. Design of electrode implantation in cadaver specimens was adapted with a trocar delivery of cables and electrodes transcutaneous and stabilization of the electrode by suturing along the nerve. In addition, the overall operating arena environment with specific positions of the multidisciplinary team necessary for implantable electrodes was elaborated to assure optimal operating conditions and procedures during the organization of a first-in-man implantation study. Overall importance of plastic surgery training for new and highly technical procedures is of importance and particularly there is a real need to continue actual cadaveric training due to patient variability for nerve anatomic structures. PMID:28723767

  7. The Challenge of the Future. Future Trends in Adult and Continuing Technical and Vocational Education. An International Symposium (Berlin, Germany, October 16-20, 1995).

    ERIC Educational Resources Information Center

    United Nations Educational, Scientific, and Cultural Organization, Hamburg (Germany). Inst. for Education.

    This report on an international symposium on the strengthening of the development and improvement of vocational education begins with a description of UNEVOC, the International Project on Technical and Vocational Education. Section 2 presents discussions of the following topics: adult and continuing technical and vocational education and its…

  8. The automated array assembly task of the low-cost silicon solar array project, phase 2

    NASA Technical Reports Server (NTRS)

    Coleman, M. G.; Pryor, R. A.; Sparks, T. G.; Legge, R.; Saltzman, D. L.

    1980-01-01

    Several specific processing steps as part of a total process sequence for manufacturing silicon solar cells were studied. Ion implantation was identified as the preferred process step for impurity doping. Unanalyzed beam ion implantation was shown to have major cost advantages over analyzed beam implantation. Further, high quality cells were fabricated using a high current unanalyzed beam. Mechanically masked plasma patterning of silicon nitride was shown to be capable of forming fine lines on silicon surfaces with spacings between mask and substrate as great as 250 micrometers. Extensive work was performed on advances in plated metallization. The need for the thick electroless palladium layer was eliminated. Further, copper was successfully utilized as a conductor layer utilizing nickel as a barrier to copper diffusion into the silicon. Plasma etching of silicon for texturing and saw damage removal was shown technically feasible but not cost effective compared to wet chemical etching techniques.

  9. [Fully implantable hearing systems].

    PubMed

    Maurer, J

    2009-03-01

    As yet comparatively little experience has been gained with fully implantable hearing systems, as the two systems available at present have only recently received CE permission for Europe and the FDA permissions are still pending in the USA. Additionally the technology is expensive and usually not covered by insurance companies. However, it could be shown that by careful patient selection and very careful surgical techniques, good results can be achieved with this highly sensitive technology, often with better patient satisfaction and hearing quality than with conventional hearing aids. To spread the technology further, the systems must also show reliable results on a broad application. Further surgery to change the batteries should not be necessary more frequently than with cardiac pacemakers. Not all technical problems are finally solved. However, it is to be foreseen that fully implantable hearing systems will be a good long-term alternative to conventional hearing aids for some patients.

  10. Transhepatic implant of a trimmed Melody™ valved stent in tricuspid position in a 1-year-old infant.

    PubMed

    Cools, Bjorn; Rega, Filip; Gewillig, Marc

    2017-02-15

    Percutaneous valved stent implantation is precluded in small infants because large delivery sheaths and large devices. We describe a procedure in a 1-year-old boy in whom a 19 mm Epic™ valve in tricuspid position had become dysfunctional. As the internal diameter of the prosthetic valve was about 16 mm, the only available valve was the Melody™ valved stent. Technical modifications were required to address issues like venous access, the bulky delivery system, and the length of the valved stent. The Melody™ valved stent was surgically trimmed and mounted on a 16 mm Tyshak balloon, access was provided transhepatically through a short 18 Fr sheath. After deployment, the intrahepatic route was sealed with two vascular plugs (8 and 10 mm) in tandem. The procedure was uncomplicated with perfect valve function 18 months after implant. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  11. Piezosurgery in implant dentistry

    PubMed Central

    Stübinger, Stefan; Stricker, Andres; Berg, Britt-Isabelle

    2015-01-01

    Piezosurgery, or the use of piezoelectric devices, is being applied increasingly in oral and maxillofacial surgery. The main advantages of this technique are precise and selective cuttings, the avoidance of thermal damage, and the preservation of soft-tissue structures. Through the application of piezoelectric surgery, implant-site preparation, bone grafting, sinus-floor elevation, edentulous ridge splitting or the lateralization of the inferior alveolar nerve are very technically feasible. This clinical overview gives a short summary of the current literature and outlines the advantages and disadvantages of piezoelectric bone surgery in implant dentistry. Overall, piezoelectric surgery is superior to other methods that utilize mechanical instruments. Handling of delicate or compromised hard- and soft-tissue conditions can be performed with less risk for the patient. With respect to current and future innovative surgical concepts, piezoelectric surgery offers a wide range of new possibilities to perform customized and minimally invasive osteotomies. PMID:26635486

  12. MemoryShape: impact of clinical trials, global medical economics, and the future.

    PubMed

    Cunningham, Bruce L; Suszynski, Thomas; Sieber, David A

    2014-09-01

    The global breast implant business was invented and configured by American plastic surgeons. In 2012, the first shaped silicone implants were approved in the United States by the Food and Drug Administration. It is the peculiar historical course of implant usage in America that has deprived US plastic surgeons of the opportunity to become experts in the use of this device. Most studies indicate significant safety benefits to using shaped devices, despite the technical challenges involved in their use. Upon approval, adoption of the devices has been slow in the United States, running the risk that American plastic surgery may lose the intellectual and clinical practice hegemony it has enjoyed for over 50 years in this area of the specialty. To continue to maintain leadership in the field of breast surgery, US surgeons should evaluate this new modality and either join the global trend or present data to contradict it.

  13. MACCIS 2.0 - An Architecture Description Framework for Technical Infostructures and Their Enterprise Environment

    DTIC Science & Technology

    2004-06-01

    Viewpoint Component Viewpoint View Architecture Description of Enterprise or Infostructure View Security Concern Business Security Model Business...security concern, when applied to the different viewpoints, addresses both stakeholders, and is described as a business security model or component...Viewpoint View Architecture Description of Enterprise or Infostructure View Security Concern Business Security Model Business Stakeholder IT Architect

  14. Dental Implants in an Aged Population: Evaluation of Periodontal Health, Bone Loss, Implant Survival, and Quality of Life.

    PubMed

    Becker, William; Hujoel, Philippe; Becker, Burton E; Wohrle, Peter

    2016-06-01

    To evaluate aged partially and fully edentulous patients who received dental implants and were maintained over time. Further, to determine how the partially and edentulous ageing populations (65 and above) with dental implants maintain bone levels, proper oral hygiene, and perceive benefits of dental implants. Since 1995, patients receiving dental implants have been prospectively entered into an Access-based computerized program (Triton Tacking System). Patient demographics (age, sex), bone quality, quantity, implant location, and type of surgery have been continuously entered into the database. The database was queried for patients receiving implants (first stage) between 66 and 93 years of age. Thirty-one patients were within this age group. Twenty-five patients returned to the clinic for periodontal and dental implant evaluation. The Periodontal Index was used to evaluate selected teeth in terms of probing depth, bleeding on probing, plaque accumulation, and mobility. Using NIH Image J, radiographs taken at second stage and last examination were measured for changes in interproximal bone levels. Once identified, each patient anomalously filled out an abbreviated quality of health life form. Due to small sample size, descriptive statistics were used to compare clinical findings. Fifteen males ranging from 78 to 84 (mean age 84 years) years and 16 females from 66 to 93 (mean age 83 years) (age range 66-93) were contacted by phone or mail and asked to return to our office for a re-examination. For this group, the first dental implants were placed in 1996 (n = initial two implants) and continuously recorded through 2013 (n = last seven implants). Thirty-one patients received a total of 84 implants. Two patients were edentulous, and the remaining were partially edentulous. Four implants were lost. Between implant placement and 6- to 7-year interval, 13 patients with 40 implants had a cumulative survival rate of 94.6%. Of the original group (n = 33), three were deceased, two were in nursing homes, and three could not be located. Aged patients receiving dental implants had excellent implant survival rates, low periodontal disease index scores with minimal changes in interproximal bone levels. Results from this study indicate that patients with advanced age, in reasonably good health, have excellent implant survival rates, excellent quality of life scores, and can be maintained in good oral health. © 2015 Wiley Periodicals, Inc.

  15. Atomically resolved tissue integration.

    PubMed

    Karlsson, Johan; Sundell, Gustav; Thuvander, Mattias; Andersson, Martin

    2014-08-13

    In the field of biomedical technology, a critical aspect is the ability to control and understand the integration of an implantable device in living tissue. Despite the technical advances in the development of biomaterials, the elaborate interplay encompassing materials science and biology on the atomic level is not very well understood. Within implantology, anchoring a biomaterial device into bone tissue is termed osseointegration. In the most accepted theory, osseointegration is defined as an interfacial bonding between implant and bone; however, there is lack of experimental evidence to confirm this. Here we show that atom probe tomography can be used to study the implant-tissue interaction, allowing for three-dimensional atomic mapping of the interface region. Interestingly, our analyses demonstrated that direct contact between Ca atoms and the implanted titanium oxide surface is formed without the presence of a protein interlayer, which means that a pure inorganic interface is created, hence giving experimental support to the current theory of osseointegration. We foresee that this result will be of importance in the development of future biomaterials as well as in the design of in vitro evaluation techniques.

  16. Bone augmentation in dental implantology using press-fit bone cylinders and twin-principle diamond hollow drills: a case series.

    PubMed

    Draenert, Florian Guy; Huetzen, Dominic; Kämmerer, Peer; Wagner, Wilfried

    2011-09-01

    Bone transplants are mostly prepared with cutting drills, chisels, and rasps. These techniques are difficult for unexperienced surgeons, and the implant interface is less precise due to unstandardized preparation. Cylindrical bone transplants are a known alternative. Current techniques include fixation methods with osteosynthesis screws or the dental implant. A new bone cylinder transplant technique is presented using a twin-drill principle resulting in a customized pressfit of the transplant without fixation devices and combining this with the superior grinding properties of a diamond coating. New cylindrical diamond hollow drills are used for customized press fit bone transplants in a case series of five patients for socket reconstruction in the front and molar region of maxilla and mandibula with and without simultaneous implant placement. The technical approach was successful without intra or postoperative complications during the acute healing phase. The customized press fit completes a technological trias of bone cylinder transplant techniques adding to the assisted press fit with either osteosynthesis screws or the dental implant itself. © 2009 Wiley Periodicals, Inc.

  17. A high-power versatile wireless power transfer for biomedical implants.

    PubMed

    Jiang, Hao; Zhang, Jun Min; Liou, Shy Shenq; Fechter, Richard; Hirose, Shinjiro; Harrison, Michael; Roy, Shuvo

    2010-01-01

    Implantable biomedical actuators are highly desired in modern medicine. However, how to power up these biomedical implants remains a challenge since most of them need more than several hundreds mW of power. The air-core based radio-frequency transformer (two face-to-face inductive coils) has been the only non-toxic and non-invasive power source for implants for the last three decades [1]. For various technical constraints, the maximum delivered power is limited by this approach. The highest delivered power reported is 275 mW over 1 cm distance [2]. Also, the delivered power is highly vulnerable to the coils' geometrical arrangement and the electrical property of the medium around them. In this paper, a novel rotating-magnets based wireless power transfer that can deliver ∼10 W over 1 cm is demonstrated. The delivered power is significantly higher than the existing start-of-art. Further, the new method is versatile since there is no need to have the impedance matching networks that are highly susceptible to the operating frequency, the coil arrangement and the environment.

  18. Advances in Cochlear Implant Telemetry: Evoked Neural Responses, Electrical Field Imaging, and Technical Integrity

    PubMed Central

    Mens, Lucas H. M.

    2007-01-01

    During the last decade, cochlear implantation has evolved into a well-established treatment of deafness, predominantly because of many improvements in speech processing and the controlled excitation of the auditory nerve. Cochlear implants now also feature telemetry, which is highly useful to monitor the proper functioning of the implanted electronics and electrode contacts. Telemetry can also support the clinical management in young children and difficult cases where neural unresponsiveness is suspected. This article will review recent advances in the telemetry of the electrically evoked compound action potential that have made these measurements simple and routine procedures in most cases. The distribution of the electrical stimulus itself sampled by “electrical field imaging” reveals general patterns of current flow in the normal cochlea and gross abnormalities in individual patients; models have been developed to derive more subtle insights from an individual electrical field imaging. Finally, some thoughts are given to the extended application of telemetry, for example, in monitoring the neural responses or in combination with other treatments of the deaf ear. PMID:17709572

  19. Atmospheric turbulence simulation for Shuttle orbiter

    NASA Technical Reports Server (NTRS)

    Tatom, F. B.; Smith, S. R.

    1979-01-01

    An improved non-recursive model for atmospheric turbulence along the flight path of the Shuttle Orbiter is developed which provides for simulation of instantaneous vertical and horizontal gusts at the vehicle center-of-gravity, and also for simulation of instantaneous gust gradients. Based on this model the time series for both gusts and gust gradients are generated and stored on a series of magnetic tapes. Section 2 provides a description of the various technical considerations associated with the turbulence simulation model. Included in this section are descriptions of the digital filter simulation model, the von Karman spectra with finite upper limits, and the final non recursive turbulence simulation model which was used to generate the time series. Section 2 provides a description of the various technical considerations associated with the turbulence simulation model. Included in this section are descriptions of the digial filter simulation model, the von Karman spectra with finite upper limits, and the final non recursive turbulence simulation model which was used to generate the time series. Section 3 provides a description of the time series as currently recorded on magnetic tape. Conclusions and recommendations are presented in Section 4.

  20. The In Vivo Pericapsular Tissue Response to Modern Polyurethane Breast Implants.

    PubMed

    Frame, James; Kamel, Dia; Olivan, Marcelo; Cintra, Henrique

    2015-10-01

    Polyurethane breast implants were first introduced by Ashley (Plast Reconstr Surg 45:421-424, 1970), with the intention of trying to reduce the high incidence of capsular contracture associated with smooth shelled, high gel bleed, silicone breast implants. The sterilization of the polyurethane foam in the early days was questionable. More recently, ethylene oxide (ETO)-sterilized polyurethane has been used in the manufacturing process and this has been shown to reduce the incidence of biofilm. The improved method of attachment of polyurethane onto the underlying high cohesive gel, barrier shell layered, silicone breast implants also encourages bio-integration. Polyurethane covered, cohesive gel, silicone implants have also been shown to reduce the incidence of other problems commonly associated with smooth or textured silicone implants, especially with reference to displacement, capsular contracture, seroma, reoperation, biofilm and implant rupture. Since the introduction of the conical polyurethane implant (Silimed, Brazil) into the United Kingdom in 2009 (Eurosurgical, UK), we have had the opportunity to review histology taken from the capsules of polyurethane implants in three women ranging from a few months to over 3 years after implantation. All implants had been inserted into virgin subfascial, extra-pectoral planes. The results add to the important previously described histological findings of Bassetto et al. (Aesthet Plast Surg 34:481-485, 2010). Five distinct layers are identified and reasons for the development of each layer are discussed. Breast capsule around polyurethane implants, in situ for fifteen and 20 years, has recently been obtained and analysed in Brazil, and the histology has been incorporated into this study. After 20 years, the polyurethane is almost undetectable and capsular contracture may appear. These findings contribute to our understanding of polyurethane implant safety, and give reasoning for a significant reduction in clinical capsular contracture rate, up to 10 years after implantation, compared to contemporary silicone implants. A more permanent matrix equivalent to polyurethane may be the solution for reducing long-term capsular contracture. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  1. DEVELOPMENT OF INTERNATIONAL STANDARDS FOR AIR QUALITY MONITORING AND CONTROL

    EPA Science Inventory

    This report presents a description of the activities and accomplishments of the American Society for Testing and Materials' U. S. Technical Advisory Group (TAG) to the International Standards Organization's Technical Committee 146 on Air Quality. The purpose of the TAG is to re...

  2. ECOS E-MATRIX Methane and Volatile Organic Carbon (VOC) Emissions Best Practices Database

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parisien, Lia

    2016-01-31

    This final scientific/technical report on the ECOS e-MATRIX Methane and Volatile Organic Carbon (VOC) Emissions Best Practices Database provides a disclaimer and acknowledgement, table of contents, executive summary, description of project activities, and briefing/technical presentation link.

  3. Microelectronic bioinstrumentation systems

    NASA Technical Reports Server (NTRS)

    Ko, W. H.; Hynecek, J.

    1975-01-01

    The possibility of using RF fields to power biologically implanted transmitters used in biomedical experiments was investigated. This approach would be especially useful when animal subjects are strapped in chairs or confined in cages. A telemetry system using an external source of energy has the additional advantage of not being limited in operation by battery lifetime and can therefore operate for virtually infinite lengths of time. A description of a system based on this principle is given. Progress in the development of battery-driven transmitters is also reported, including an ingestible temperature telemetry system and a resistance-to-pulse frequency convertor for implantable temperature telemetry systems.

  4. Oral health-related quality of life of implant-supported overdentures versus conventional complete prostheses: Retrospective study of a cohort of edentulous patients

    PubMed Central

    Selva-Otaolaurruchi, Eduardo J.; Montero, Javier; Sola-Ruiz, Fernanda

    2015-01-01

    Background This work aims to confirm if implant-supported overdentures are a good treatment option for edentulous patients and offer an improvement in quality of life compared with traditional complete prostheses (dentures). Material and Methods This retrospective clinical descriptive study included three evaluation groups: validation group (n=57); control group of patients with complete removeable prostheses (n=56); study group of patients with implant-supported overdentures retained with the Locator® system (n=80). The study also validated the Oral Health Impact Profile-20 questionnaire. Individual protocols were created that included socio-demographic data, the Oral Health Impact Profile-20 (OHIP-20) questionnaire and Oral Satisfaction Scale (OSS). Descriptive and bivariate statistical analysis was carried out applying χ², Pearson, Kruskal-Wallis, and Student t tests, transferring data into SPSS-Windows® software from a Microsoft® Excel spreadsheet. Results The OHIP-20 proved to be a valid instrument and provided reliable assessment of health-related quality of life among both the Spanish general population and edentulous patients. The control and study groups proved comparable, showing socio-demographic homogeneity. For patients with overdentures retained by means of the Locator® system, these restorations had significantly lower impact on quality of life (19 vs 33), both generally and for each individual questionnaire item, and much higher satisfaction with the state of their oral cavities (8.3 vs 5.3) than patients wearing dentures; both sets of data showed a direct linear relationship, so that as the level of impact on quality of life increased, perceived oral satisfaction worsened. Conclusions Patients rehabilitated with implant supported overdentures retained by the Locator® system, presented significantly lower levels of impact on their quality of life and significantly higher oral satisfaction than patients with conventional complete prostheses. Key words: Oral health-related quality of life, OHIP-20, OSS, overdentures, dental implants, complete prostheses, Locator® system. PMID:26034930

  5. 47 CFR 22.401 - Description and purposes of developmental authorizations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... authorizations. 22.401 Section 22.401 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES PUBLIC MOBILE SERVICES Developmental Authorizations § 22.401 Description and purposes of... technical suitability of antenna locations for stations in the Public Mobile Services; (b) Experimentation...

  6. 47 CFR 22.401 - Description and purposes of developmental authorizations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... authorizations. 22.401 Section 22.401 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES PUBLIC MOBILE SERVICES Developmental Authorizations § 22.401 Description and purposes of... technical suitability of antenna locations for stations in the Public Mobile Services; (b) Experimentation...

  7. 49 CFR 572.71 - General description.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES 6-Year-Old Child § 572.71 General description. (a) The representative 6-year-old dummy consists of a drawings and specifications package that contains the following materials: (1) Technical drawings, specifications, and the parts list...

  8. 75 FR 20869 - Advisory Committee on the Medical Uses of Isotopes: Meeting Notice

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-21

    ...; (7) an update on the status of the technical basis to support Part 35 rulemaking addressing the... events for fiscal year 2010; and (10) an issue regarding signatures for post-implant written directives...: 1. Persons who wish to provide a written statement should submit an electronic copy to Ms. Cockerham...

  9. A standardized description of graft-containing meshes and recommended steps before the introduction of medical devices for prolapse surgery. Consensus of the 2nd IUGA Grafts Roundtable: optimizing safety and appropriateness of graft use in transvaginal pelvic reconstructive surgery.

    PubMed

    Slack, Mark; Ostergard, Donald; Cervigni, Mauro; Deprest, Jan

    2012-04-01

    Over the past decade, a huge number of new implants and ancillary devices have been introduced to the market. Most of these have become clinically available with little or no clinical data or research. This is a less-than-ideal situation, and this subgroup of the ad hoc IUGA roundtable conference wants to open the discussion to change this, by proposing a pragmatic minimum clearance track for new products being introduced to the market. It consists of an accurate and more standardized product description, data on the biological properties gathered in animal experiments, anatomical cadaveric studies, and upfront clinical studies followed by a compulsory registry on the first 1,000 patients implanted. Ideally, manufacturers should support well-designed prospective (randomized) clinical trials that can support the claimed benefits of the new product.

  10. Space station systems analysis study. Part 3: Documentation. Volume 4: Supporting research and technology report

    NASA Technical Reports Server (NTRS)

    1977-01-01

    A brief description of recommended supporting research and technology items resulting from the space station analysis study is provided. Descriptions include the title; the status with respect to the state of the art; the justification; the technical plan including objectives and technical approach; resource requirements categorized by manpower, specialized facilities, and funding in 1977 dollars; and also the target schedule. The goal is to provide high confidence in the solutions for the various functional system development problems, and to do so within a time period compatible with the overall evolutionary space construction base schedule.

  11. Percutaneous transfemoral-transseptal implantation of a second-generation CardiAQ mitral valve bioprosthesis: first procedure description and 30-day follow-up.

    PubMed

    Ussia, Gian Paolo; Quadri, Arshad; Cammalleri, Valeria; De Vico, Pasquale; Muscoli, Saverio; Marchei, Massimo; Ruvolo, Giovanni; Sondergaard, Lars; Romeo, Francesco

    2016-02-01

    Transcatheter mitral valve implantation for mitral valve regurgitation is in the very early phase of development because of challenging anatomy and device dimensions. We describe the procedure of a transfemoral-transseptal implantation of the second-generation CardiAQ mitral valve bioprosthesis and 30-day follow-up. The procedure was performed percutaneously, without any left extracorporeal circulatory support. The patient had severe mitral regurgitation with severely depressed ventricular function and other comorbidities. The patient was deemed extreme high risk for conventional cardiac surgery by a multidisciplinary team. The main procedural steps were the creation of an arteriovenous loop with an exchange nitinol wire, and the use of a customised "steerable snare system" to facilitate the catheter delivery system into the mitral annulus. Transoesophageal echocardiography and fluoroscopy were utilised for device positioning and deployment. The mitral valve prosthesis was implanted with mild mitral regurgitation. The postoperative course was uneventful and at 30-day follow-up the patient is in NYHA Class I, with good function of the mitral valve bioprosthesis. This procedure shows that percutaneous transfemoral transcatheter mitral valve implantation is feasible, safe and successful. Further experience is needed to render this procedure clinically available.

  12. Models and signal processing for an implanted ethanol bio-sensor.

    PubMed

    Han, Jae-Joon; Doerschuk, Peter C; Gelfand, Saul B; O'Connor, Sean J

    2008-02-01

    The understanding of drinking patterns leading to alcoholism has been hindered by an inability to unobtrusively measure ethanol consumption over periods of weeks to months in the community environment. An implantable ethanol sensor is under development using microelectromechanical systems technology. For safety and user acceptability issues, the sensor will be implanted subcutaneously and, therefore, measure peripheral-tissue ethanol concentration. Determining ethanol consumption and kinetics in other compartments from the time course of peripheral-tissue ethanol concentration requires sophisticated signal processing based on detailed descriptions of the relevant physiology. A statistical signal processing system based on detailed models of the physiology and using extended Kalman filtering and dynamic programming tools is described which can estimate the time series of ethanol concentration in blood, liver, and peripheral tissue and the time series of ethanol consumption based on peripheral-tissue ethanol concentration measurements.

  13. Proximate factors associated with speech intelligibility in children with cochlear implants: A preliminary study.

    PubMed

    Chin, Steven B; Kuhns, Matthew J

    2014-01-01

    The purpose of this descriptive pilot study was to examine possible relationships among speech intelligibility and structural characteristics of speech in children who use cochlear implants. The Beginners Intelligibility Test (BIT) was administered to 10 children with cochlear implants, and the intelligibility of the words in the sentences was judged by panels of naïve adult listeners. Additionally, several qualitative and quantitative measures of word omission, segment correctness, duration, and intonation variability were applied to the sentences used to assess intelligibility. Correlational analyses were conducted to determine if BIT scores and the other speech parameters were related. There was a significant correlation between BIT score and percent words omitted, but no other variables correlated significantly with BIT score. The correlation between intelligibility and word omission may be task-specific as well as reflective of memory limitations.

  14. Writing a technical note.

    PubMed

    Ng, K H; Peh, W C G

    2010-02-01

    A technical note is a short article giving a brief description of a specific development, technique or procedure, or it may describe a modification of an existing technique, procedure or device applicable to medicine. The technique, procedure or device described should have practical value and should contribute to clinical diagnosis or management. It could also present a software tool, or an experimental or computational method. Technical notes are variously referred to as technical innovations or technical developments. The main criteria for publication will be the novelty of concepts involved, the validity of the technique and its potential for clinical applications.

  15. Teaching Leadership in Technical Programs at Community Colleges

    ERIC Educational Resources Information Center

    DeBlauw, Amanda L.; Daugherty, Jenny L.

    2017-01-01

    This descriptive study explored how community colleges are teaching leadership in technical programs. Leadership education curricular offerings were identified via a survey and selected programs reviewed. 68 Deans, Directors, or Chairpersons of a Business, Management, or Technology program completed the survey, representing 61 community colleges.…

  16. Fox Valley Technical Institute Economic Development Plan.

    ERIC Educational Resources Information Center

    Fox Valley Technical Inst., Appleton, WI.

    Designed as an operating blueprint for Fox Valley Technical Institute's (FVTI's) economic development efforts, this guide incorporates the necessary operation procedures, descriptions, and resources for those involved in FVTI's effort to assist existing businesses to expand and to attract new businesses to the area. Introductory material describes…

  17. Methodological quality and descriptive characteristics of prosthodontic-related systematic reviews.

    PubMed

    Aziz, T; Compton, S; Nassar, U; Matthews, D; Ansari, K; Flores-Mir, C

    2013-04-01

    Ideally, healthcare systematic reviews (SRs) should be beneficial to practicing professionals in making evidence-based clinical decisions. However, the conclusions drawn from SRs are directly related to the quality of the SR and of the included studies. The aim was to investigate the methodological quality and key descriptive characteristics of SRs published in prosthodontics. Methodological quality was analysed using the Assessment of Multiple Reviews (AMSTAR) tool. Several electronic resources (MEDLINE, EMBASE, Web of Science and American Dental Association's Evidence-based Dentistry website) were searched. In total 106 SRs were located. Key descriptive characteristics and methodological quality features were gathered and assessed, and descriptive and inferential statistical testing performed. Most SRs in this sample originated from the European continent followed by North America. Two to five authors conducted most SRs; the majority was affiliated with academic institutions and had prior experience publishing SRs. The majority of SRs were published in specialty dentistry journals, with implant or implant-related topics, the primary topics of interest for most. According to AMSTAR, most quality aspects were adequately fulfilled by less than half of the reviews. Publication bias and grey literature searches were the most poorly adhered components. Overall, the methodological quality of the prosthodontic-related systematic was deemed limited. Future recommendations would include authors to have prior training in conducting SRs and for journals to include a universal checklist that should be adhered to address all key characteristics of an unbiased SR process. © 2013 Blackwell Publishing Ltd.

  18. Non-restraining EEG Radiotelemetry: Epidural and Deep Intracerebral Stereotaxic EEG Electrode Placement.

    PubMed

    Papazoglou, Anna; Lundt, Andreas; Wormuth, Carola; Ehninger, Dan; Henseler, Christina; Soós, Julien; Broich, Karl; Weiergräber, Marco

    2016-06-25

    Implantable EEG radiotelemetry is of central relevance in the neurological characterization of transgenic mouse models of neuropsychiatric and neurodegenerative diseases as well as epilepsies. This powerful technique does not only provide valuable insights into the underlying pathophysiological mechanisms, i.e., the etiopathogenesis of CNS related diseases, it also facilitates the development of new translational, i.e., therapeutic approaches. Whereas competing techniques that make use of recorder systems used in jackets or tethered systems suffer from their unphysiological restraining to semi-restraining character, radiotelemetric EEG recordings overcome these disadvantages. Technically, implantable EEG radiotelemetry allows for precise and highly sensitive measurement of epidural and deep, intracerebral EEGs under various physiological and pathophysiological conditions. First, we present a detailed protocol of a straight forward, successful, quick and efficient technique for epidural (surface) EEG recordings resulting in high-quality electrocorticograms. Second, we demonstrate how to implant deep, intracerebral EEG electrodes, e.g., in the hippocampus (electrohippocampogram). For both approaches, a computerized 3D stereotaxic electrode implantation system is used. The radiofrequency transmitter itself is implanted into a subcutaneous pouch in both mice and rats. Special attention also has to be paid to pre-, peri- and postoperative treatment of the experimental animals. Preoperative preparation of mice and rats, suitable anesthesia as well as postoperative treatment and pain management are described in detail.

  19. Neuromodulation by implant for treating lower urinary tract symptoms and dysfunction.

    PubMed

    Bemelmans, B L; Mundy, A R; Craggs, M D

    1999-08-01

    Patients with irritative micturition complaints, pelvic pain, involuntary urine loss or urinary retention are sometimes difficult to treat. The advent of direct sacral nerve stimulation offers a therapeutic alternative if conservative measures fail and surgery is considered. This paper reviews therapeutic neuromodulation by implant for treating lower urinary tract symptoms and dysfunction. The international literature is reviewed on topics such as the physiological basis of neuromodulation, techniques of acute testing and chronic implantation, and clinical results. Future developments and ways for possible improvement are discussed. The mode of action of neuromodulation is probably through restoring the correct balance between excitatory and inhibitory impulses from and to the pelvic organs at a sacral and supra-sacral level. Depending on the predefined success criteria, average success rates of definitive implants vary from 50 to 70%. From the data it seems that patients with urge incontinence and urinary retention are the best candidates for neuromodulation. In the literature the lack of standardisation of selection criteria, stimulation parameters and definitions of success is striking. Neuromodulation by implant is a useful therapeutic alternative. It should at least be considered in patients with therapy-resistant urge incontinence and urinary retention before proceeding to surgery. Issues such as underlying physiology, methodological standardisation, technical improvements, and patient selection must be addressed in future research.

  20. Two different techniques of manufacturing TMJ replacements - A technical report.

    PubMed

    Kozakiewicz, Marcin; Wach, Tomasz; Szymor, Piotr; Zieliński, Rafał

    2017-09-01

    Presently, during the surgical treatment of the patients in maxillofacial surgery, one can use various medical implants. Moreover custom made implants are being used. Replacements may be fitted to the structure and shape of the human skull owing to CAD/CAM (custom aided design/manufacture) called customized implants. This study was aimed to report for the first time clinical material from which custom implants, using two different techniques, were manufactured to reconstruct the temporomandibular joint (TMJ). In this study, eleven patients with an average age of 54 years were included. All of the patients underwent TMJ reconstruction using direct metal laser sintering (DMLS) or computer numerical control milling (CNC) techniques for implant manufacture. Four of the eleven patients had a malignancy diagnosis, and seven had a benign diagnosis. Patients complained of hypomobility of the TMJ, facial asymmetry, pain and swelling of the preauricular region. Treatment included 7 CNC milled implants and 4 implants in DMLS. More metallic implant parts with a rough surface were associated with the DMLS technique. Post operational, uneventful healing was observed in all clinical cases during an average of 26.8 months of follow-up. Three months post-operation, facial nerve palsy, swallowing disturbances and pain were not observed. Infections, allergic reactions to materials and re-ankylosis were also not observed. Replacements received correct forms and functions owing to the CAM techniques. Post-operational maximal interincisal opening improved (p < 0.01) and was not significantly related to preoperational opening, age, sex, diagnosis or adjuvant radiotherapy. Considering both methods, the feature that differentiates the manufacture technique is the more subtractive surface finishing required for the DMLS implant than the CNC implant. Both techniques resulted the same clinical outcomes and can be used successfully in patients with neoplastic lesions and other TMJ disorders. Unfortunately, DMLS is more vulnerable to fracture. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Advanced reactor site feasibility evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haynes, Mark; Owens, Martin; Southworth, Finis

    The report provides a description of the project, summarizes the methodology and results for each task of the project, and ends with the overall project conclusions and recommendations. In addition, the report contains a descriptive index of the technical reports generated during the course of the project.

  2. FINAL PROJECT REPORT - EVALUATION AND TESTING OF HTGR REACTOR BUILDING RESPONSE TO DEPRESSURIZATION ACCIDENTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ALLIANCE LIMITED, NGNP INDUSTRY

    This report provides a description of the project, summarizes each phase of the project, and ends with project conclusions. In addition, the report contains a descriptive index of the technical reports generated during the course of the project.

  3. 49 CFR 572.141 - General description.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES 3-year-Old Child Crash Test Dummy, Alpha Version § 572.141 General description. (a) The Hybrid III 3-year-old child dummy is described by the following materials: (1) Technical drawings and specifications package 210-0000 (refer to...

  4. Covered Biodegradable Stent: New Therapeutic Option for the Management of Esophageal Perforation or Anastomotic Leak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cerna, Marie; Koecher, Martin, E-mail: martin.kocher@seznam.cz; Valek, Vlastimil

    2011-12-15

    Purpose: This study was designed to evaluate our experience with the treatment of postoperative anastomotic leaks and benign esophageal perforations with covered biodegradable stents. Materials and Methods: From 2008 to 2010, we treated five men with either an anastomotic leak or benign esophageal perforation by implanting of covered biodegradable Ella-BD stents. The average age of the patients was 60 (range, 38-74) years. Postoperative anastomotic leaks were treated in four patients (1 after esophagectomy, 1 after resection of diverticulum, 2 after gastrectomy). In one patient, perforation occurred as a complication of the treatment of an esophageal rupture (which occurred during amore » balloon dilatation of benign stenosis) with a metallic stent. Results: Seven covered biodegradable stents were implanted in five patients. Primary technical success was 100%. Clinical success (leak sealing) was achieved in four of the five patients (80%). Stent migration occurred in three patients. In two of these patients, the leak had been sealed by the time of stent migration, therefore no reintervention was necessary. In one patient an additional stent had to be implanted. Conclusion: The use of biodegradable covered stents for the treatment of anastomotic leaks or esophageal perforations is technically feasible and safe. The initial results are promising; however, larger number of patients will be required to evaluate the capability of these biodegradable stents in the future. The use of biodegradable material for coverage of the stent is essential.« less

  5. Training considerations for the intracoelomic implantation of electronic tags in fish with a summary of common surgical errors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cooke, Steven J.; Wagner, Glenn N.; Brown, Richard S.

    2011-01-01

    Training is a fundamental part of all scientific and technical disciplines. This is particularly true for all types of surgeons. For surgical procedures, a number of skills are necessary to reduce mistakes. Trainees must learn an extensive yet standardized set of problem-solving and technical skills to handle challenges as they arise. There are currently no guidelines or consistent training methods for those intending to implant electronic tags in fish; this is surprising, considering documented cases of negative consequences of fish surgeries and information from studies having empirically tested fish surgical techniques. Learning how to do fish surgery once is insufficientmore » for ensuring the maintenance or improvement of surgical skill. Assessment of surgical skills is rarely incorporated into training, and is needed. Evaluation provides useful feedback that guides future learning, fosters habits of self-reflection and self-remediation, and promotes access to advanced training. Veterinary professionals should be involved in aspects of training to monitor basic surgical principles. We identified attributes related to knowledge, understanding, and skill that surgeons must demonstrate prior to performing fish surgery including a “hands-on” assessment using live fish. Included is a summary of common problems encountered by fish surgeons. We conclude by presenting core competencies that should be required as well as outlining a 3-day curriculum for training surgeons to conduct intracoelomic implantation of electronic tags. This curriculum could be offered through professional fisheries societies as professional development courses.« less

  6. Implantation of Right Kidneys: Is the Risk of Technical Graft Loss Real?

    PubMed

    Khan, Taqi T; Ahmad, Nadeem; Siddique, Kashif; Fourtounas, Konstantinos

    2018-05-01

    The left kidney (LK) is preferred by transplant surgeons, because its vein is always of good length and has a thick wall that enables safe suturing. On the other hand, the right renal vein is generally shorter and thinner walled, and well known for its technical difficulty during venous anastomosis, and can result in graft loss. We examined our living (LD) and deceased donor (DD) recipient data and compared the incidence of technical graft loss and early graft function in right and left kidneys. A cohort of 58 adult and pediatric recipients received an LD or DD kidney between January 2015 and December 2016. The donor and recipient data were retrieved and retrospectively analyzed. Technical graft loss was defined as graft thrombosis within the 7 days after transplant. Right kidneys (RKs) were not a risk factor for technical graft loss, and no graft was lost for technical reasons in either LD or DD transplants. Early graft function in LK and RKs was also comparable in the LD cohort, and there were no LKs in the DD cohort. Based on our data, the use of RKs was not a risk factor for technical graft loss and early graft function was comparable to LKs.

  7. Characterisation of slab waveguides, fabricated in CaF2 and Er-doped tungsten-tellurite glass by MeV energy N+ ion implantation, using spectroscopic ellipsometry and m-line spectroscopy

    NASA Astrophysics Data System (ADS)

    Bányász, I.; Berneschi, S.; Lohner, T.; Fried, M.; Petrik, P.; Khanh, N. Q.; Zolnai, Z.; Watterich, A.; Bettinelli, M.; Brenci, M.; Nunzi-Conti, G.; Pelli, S.; Righini, G. C.; Speghini, A.

    2010-05-01

    Slab waveguides were fabricated in Er-doped tungsten-tellurite glass and CaF2 crystal samples via ion implantation. Waveguides were fabricated by implantation of MeV energy N+ ions at the Van de Graaff accelerator of the Research Institute for Particle and Nuclear Physics, Budapest, Hungary. Part of the samples was annealed. Implantations were carried out at energies of 1.5 MeV (tungsten-tellurite glass) and 3.5 MeV (CaF2). The implanted doses were between 5 x 1012 and 8 x 1016 ions/cm2. Refractive index profile of the waveguides was measured using SOPRA ES4G and Woollam M-2000DI spectroscopic ellipsometers at the Research Institute for Technical Physics and Materials Science, Budapest. Functionality of the waveguides was tested using a home-made instrument (COMPASSO), based on m-line spectroscopy and prism coupling technique, which was developed at the Materials and Photonics Devices Laboratory (MDF Lab.) of the Institute of Applied Physics in Sesto Fiorentino, Italy. Results of both types of measurements were compared to depth distributions of nuclear damage in the samples, calculated by SRIM 2007 code. Thicknesses of the guiding layer and of the implanted barrier obtained by spectroscopic ellipsometry correspond well to SRIM simulations. Irradiationinduced refractive index modulation saturated around a dose of 8 x 1016 ions/cm2 in tungsten-tellurite glass. Annealing of the implanted waveguides resulted in a reduction of the propagation loss, but also reduced the number of supported guiding modes at the lower doses. We report on the first working waveguides fabricated in an alkali earth halide crystal implanted by MeV energy medium-mass ions.

  8. Dental implant suprastructures using cobalt-chromium alloy compared with gold alloy framework veneered with ceramic or acrylic resin: a retrospective cohort study up to 18 years.

    PubMed

    Teigen, Kyrre; Jokstad, Asbjørn

    2012-07-01

    An association between the long-term success and survival of implant-supported prostheses as a function of biomaterial combinations has not been established. The use of cast cobalt-chromium for the suprastructure framework may be an alternative to the conventional approach of using type 3 gold alloys. A retrospective chart audit of all patients who had received implant-supported fixed dental prostheses (FDP) before 1996 was identified in a private practice clinic. Data were recorded for FDPs made from four combinations of alloy frameworks and veneering material, i.e. type 3 gold and cobalt-chromium with ceramic or prefabricated acrylic teeth. The extracted data from the charts were subjected to explorative statistical tests including Kaplan-Meier survival analyses. Patients (n=198) with 270 short and extensive FDPs supported entirely by 1117 implants were identified. The average follow-up observation periods varied between 4 and 220 months, with an average of 120 months. The success and survival, as well as event rates and types of biological and technical complications, were similar for implant-supported FDPs using cobalt-chromium and type 3 gold alloy frameworks veneered with ceramics or prefabricated acrylic teeth. An influence of the suprastructure biomaterial combination on the clinical performance of the individual supporting implants could not be established. Implant-supported FDPs made from type 3 gold or cobalt-chromium frameworks and veneered with ceramic or prefabricated acrylic teeth demonstrate comparable clinical performance. The biomaterial combinations do not appear to influence the success or survival of the individual implants. © 2011 John Wiley & Sons A/S.

  9. OHRQoL, masticatory performance and crestal bone loss with single-implant, magnet-retained mandibular overdentures with conventional and shortened dental arch.

    PubMed

    Grover, Manita; Vaidyanathan, Anand Kumar; Veeravalli, Padmanabhan Thallam

    2014-05-01

    The aim of this study was to assess the use of single implant-supported, magnet-retained mandibular overdentures to improve the oral health-related quality of life (OHRQoL) and masticatory performance of patients wearing conventional complete dentures. The study also aimed at comparing the OHRQoL, masticatory performance, and crestal bone loss with two different types of overdenture prosthesis. Ten completely edentulous patients with atrophic mandibular residual alveolar ridges and having difficulty coping with technically adequate mandibular dentures were selected for implant-supported overdentures (ISOD). To assess the success of the implant fixture clinically, a crossover study design was followed, and the patients were divided into two groups. Group A received ISOD with conventional complete dental arch, and group B received ISOD with a shortened dental arch for the first 3 months and vice versa for the next 3 months. The OHRQoL was measured with the OHIP-49 questionnaire, and masticatory performance was assessed with the sieve method using peanuts as test food. Peri-apical radiographs were taken to evaluate the crestal bone loss. A significant improvement was seen both subjectively and objectively when conventional complete dentures were modified to implant-supported prosthesis. When comparing the implant overdenture prosthesis, patients were more satisfied with conventional arch than with the shortened dental arch. In the first 3 months following implant placement, less bone loss was seen with the shortened dental arch overdenture (P < 0.05). Single implant-supported, magnet-retained mandibular overdentures significantly improve the OHRQoL of completely edentulous patients. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  10. A Retrospective Multicentre Cohort Review of Patient Characteristics and Surgical Aspects versus the Long-Term Outcomes for Recipients of a Fully Implantable Active Middle Ear Implant

    PubMed Central

    Lefebvre, Philippe P.; Gisbert, Javier; Cuda, Domenico; Tringali, Stéphane; Deveze, Arnaud

    2017-01-01

    Objective To summarise treatment outcomes compared to surgical and patient variables for a multicentre recipient cohort using a fully implantable active middle ear implant for hearing impairment. To describe the authors' preferred surgical technique to determine microphone placement. Study Design Multicentre retrospective, observational survey. Setting Five tertiary referral centres. Patients Carina recipients (66 ears, 62 subjects) using the current Cochlear® Carina® System or the legacy device, the Otologics® Fully Implantable Middle Ear, with a T2 transducer. Methods Patient file review and routine clinical review. Patient outcomes assessed were satisfaction, daily use and feedback reports at the first fitting and ≥12 months after implantation. Descriptive and statistical analysis of correlations of variables and their influence on outcomes was performed. Independently reported preferred methods for microphone placement are collectively summarised. Results The average implant experience was 3.5 years. Satisfaction increased significantly over time (p < 0.05). No correlation with covariates examined was observed. Feedback significantly decreased over time, showing a significant correlation with microphone location, primary motivation, gender, age at implantation, and contralateral hearing aid use (p < 0.05). Patient satisfaction was inversely correlated with reports of system feedback (p < 0.05). The implantable microphone was most commonly on the posterior inferior mastoid line, in 42/66 (65%) cases, correlating with less likelihood for feedback and consistent with author surgical preference. Conclusion Carina recipients in this study present as satisfied consistent daily users with very few reports of persistent feedback. As microphone location is an influencing factor, a careful surgical consideration of microphone placement is required. The authors prefer a posterior inferior mastoid line position whenever possible. PMID:28052264

  11. Facial nerve stimulation associated with cochlear implant use following temporal bone fractures.

    PubMed

    Espahbodi, Mana; Sweeney, Alex D; Lennon, Kristen J; Wanna, George B

    2015-01-01

    To describe the incidence and management of patients with facial nerve stimulation (FNS) associated with cochlear implant (CI) use in the setting of a prior temporal bone fracture. One adult CI recipient is reported who experienced implant associated FNS with a history of a temporal bone fracture. Additionally, a literature search was performed to identify similar patients from previous descriptions of CI related FNS. Presence of FNS after implantation and ability to modify implant programming to avoid FNS. The patient in the present report experienced FNS for middle and basal electrodes during intraoperative neural response telemetry (NRT) in the absence of any surgical exposure or manipulation of the facial nerve. FNS was absent during device activation, but it recurred during follow-up programming sessions. However, additional programming has prevented further FNS during regular implant use. Four other patients with FNS after temporal bone fracture were identified from the literature, and the present case represents the one of two cases in which reprogramming allowed for implant use without FNS. CI associated FNS is uncommon in patients with a history of a temporal bone fracture, but it is likely that fracture lines provide a lower impedance pathway to the adjacent facial nerve and thus reduce the threshold for FNS. The present report suggests that, in the setting of a prior temporal bone fracture, NRT is not always a reliable predictor of FNS during implant use, and programming changes can help to mitigate FNS when it occurs. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. The Overall Survival, Complication-Free Survival, and Related Complications of Combined Tooth-Implant Fixed Partial Dentures: A Literature Review

    PubMed Central

    Borg, Peter; Puryer, James; McNally, Lisa; O’Sullivan, Dominic

    2016-01-01

    This paper reviews the literature regarding possible complications, complication-free survival, and overall survival of fixed dental prostheses that use both implants and natural teeth as abutments. The paper also provides clinical guidelines for treatment based on this literature review. An electronic search utilizing the MEDLINE, BIOSIS Citation Index, and Web of Science™ Core Collection databases was undertaken, and a review of the 25 selected texts studying 22 different patient cohorts was carried out. From a total of 1610 implants reviewed, 40 were lost (33 due to loss of integration and 7 due to fracture), whereas, out of a total of 1301 teeth, 38 were lost, of which 16 were due to fracture. Seventy-three cases of tooth intrusion were detected. From a total of 676 frameworks reviewed (metal n = 645, Zirconia n = 31), 7 fractured, while veneer material fracture occurred in 70 out of 672 bridges. Overall, 502 out of 531 tooth-implant fixed prostheses (TIPFs) remained functional, and 336 out of 439 prostheses showed no technical or biological complications and remained functional. Rigid TIFPs permanently cemented to teeth with sufficient coronal structure and with limited use of prosthetic attachments offer a good long-term treatment option to patients with good oral hygiene following sound implant placement. This mode of treatment should be used when free-standing implant-supported options may not be possible. Larger randomized control studies and other clinical studies comparing tooth-to-implant-connected treatment with other forms of treatment are needed to better understand the place of TIFP treatment in oral rehabilitation. PMID:29563458

  13. Cochlear Implantation After Partial or Subtotal Cochleoectomy for Intracochlear Schwannoma Removal-A Technical Report.

    PubMed

    Plontke, Stefan K; Kösling, Sabrina; Rahne, Torsten

    2018-03-01

    To describe the technique for surgical tumor removal, cochlear implant (CI) electrode placement and reconstruction of the surgical defect in patients with intracochlear schwannomas. Retrospective case review. Tertiary referral center. Ten patients (five men, five women, mean age 48 ± 12 yr) with profound or severe to profound hearing loss due to intralabyrinthine schwannomas with intracochlear location. Surgical tumor removal through extended round window approach, partial or subtotal cochleoectomy with or without labyrinthectomy and reconstruction of the surgical defect with cartilage, perichondrium or temporal muscle fascia, and bone pâté. Eight patients received a cochlear implant in the same procedure. Retrospective evaluation of clinical outcome including safety aspects (adverse events) and audiological performance at early follow up in cases of cochlear implantation. The tumor was successfully removed in all cases without macroscopic (operation microscope and endoscope) tumor remnants in the bony labyrinth apart from one case with initial transmodiolar growth. One patient needed revision surgery for labyrinthine fistula. At short-term follow up (3-month post-surgery), good hearing results with the cochlear implant were obtained in all but one patient with a word recognition score of 100% for numbers, and 64 ± 14% for monosyllables (at 65 dB SPL in quiet). Surgical tumor removal and cochlear implantation is a promising treatment strategy in the management of intralabyrinthine schwannoma with intracochlear location, further extending the indication range for cochlear implantation. It is, however, of importance to observe the long-term outcome in these patients and to address challenges like follow up with magnetic resonance imaging.

  14. Oral health-related quality of life of implant-supported overdentures versus conventional complete prostheses: Retrospective study of a cohort of edentulous patients.

    PubMed

    Fernandez-Estevan, Lucia; Selva-Otaolaurruchi, Eduardo J; Montero, Javier; Sola-Ruiz, Fernanda

    2015-07-01

    This work aims to confirm if implant-supported overdentures are a good treatment option for edentulous patients and offer an improvement in quality of life compared with traditional complete prostheses (dentures). This retrospective clinical descriptive study included three evaluation groups: validation group (n=57); control group of patients with complete removeable prostheses (n=56); study group of patients with implant-supported overdentures retained with the Locator® system (n=80). The study also validated the Oral Health Impact Profile-20 questionnaire. Individual protocols were created that included socio-demographic data, the Oral Health Impact Profile-20 (OHIP-20) questionnaire and Oral Satisfaction Scale (OSS). Descriptive and bivariate statistical analysis was carried out applying χ², Pearson, Kruskal-Wallis, and Student t tests, transferring data into SPSS-Windows® software from a Microsoft® Excel spreadsheet. The OHIP-20 proved to be a valid instrument and provided reliable assessment of health-related quality of life among both the Spanish general population and edentulous patients. The control and study groups proved comparable, showing socio-demographic homogeneity. For patients with overdentures retained by means of the Locator® system, these restorations had significantly lower impact on quality of life (19 vs 33), both generally and for each individual questionnaire item, and much higher satisfaction with the state of their oral cavities (8.3 vs 5.3) than patients wearing dentures; both sets of data showed a direct linear relationship, so that as the level of impact on quality of life increased, perceived oral satisfaction worsened. Patients rehabilitated with implant supported overdentures retained by the Locator® system, presented significantly lower levels of impact on their quality of life and significantly higher oral satisfaction than patients with conventional complete prostheses.

  15. Technical aspects of CT imaging of the spine.

    PubMed

    Tins, Bernhard

    2010-11-01

    This review article discusses technical aspects of computed tomography (CT) imaging of the spine. Patient positioning, and its influence on image quality and movement artefact, is discussed. Particular emphasis is placed on the choice of scan parameters and their relation to image quality and radiation burden to the patient. Strategies to reduce radiation burden and artefact from metal implants are outlined. Data acquisition, processing, image display and steps to reduce artefact are reviewed. CT imaging of the spine is put into context with other imaging modalities for specific clinical indications or problems. This review aims to review underlying principles for image acquisition and to provide a rough guide for clinical problems without being prescriptive. Individual practice will always vary and reflect differences in local experience, technical provisions and clinical requirements.

  16. Examining Wrong Eye Implant Adverse Events in the Veterans Health Administration With a Focus on Prevention: A Preliminary Report.

    PubMed

    Neily, Julia; Chomsky, Amy; Orcutt, James; Paull, Douglas E; Mills, Peter D; Gilbert, Christina; Hemphill, Robin R; Gunnar, William

    2018-03-01

    The study goals were to examine wrong intraocular lens (IOL) implant adverse events in the Veterans Health Administration (VHA), identify root causes and contributing factors, and describe system changes that have been implemented to address this challenge. This study represents collaboration between the VHA's National Center for Patient Safety (NCPS) and the National Surgery Office (NSO). This report includes 45 wrong IOL implant surgery adverse events reported to established VHA NCPS and NSO databases between July 1, 2006, and June 31, 2014. There are approximately 50,000 eye implant procedures performed each year in the VHA. Wrong IOL implant surgery adverse events are reported by VHA facilities to the NCPS and the NSO. Two authors (A.C. and J.N.) coded the reports for event type (wrong lens or expired lens) and identified the primary contributing factor (coefficient κ = 0.837). A descriptive analysis was conducted, which included the reported yearly event rate. The main outcome measure was the reported wrong IOL implant surgery adverse events. There were 45 reported wrong IOL implant surgery adverse events. Between 2011 and June 30, 2014, there was a significant downward trend (P = 0.02, R = 99.7%) at a pace of -0.08 (per 10,000 cases) every year. The most frequently coded primary contributing factor was incomplete preprocedure time-out (n = 12) followed by failure to perform double check of preprocedural calculations based upon original data and implant read-back at the time the surgical eye implant was performed (n = 10). Preventing wrong IOL implant adverse events requires diligence beyond performance of the preprocedural time-out. In 2013, the VHA has modified policy to ensure double check of preprocedural calculations and implant read-back with positive impact. Continued analysis of contributing human factors and improved surgical team communication are warranted.

  17. What happens to an acellular dermal matrix after implantation in the human body? A histological and electron microscopic study.

    PubMed

    Boháč, Martin; Danišovič, Ľuboš; Koller, Ján; Dragúňová, Jana; Varga, Ivan

    2018-01-22

    Acellular matrices are used for various purposes and they have been studied extensively for their potential roles in regenerating tissues or organs. The acellular matrix generates physiological cues that mimic the native tissue microenvironment. Acellular dermal matrix (ADM) is a soft connective tissue graft generated by a decellularization process that preserves the intact extracellular skin matrix. Upon implantation, this structure serves as a scaffold for donor-side cells to facilitate subsequent incorporation and revascularization. In breast reconstruction, ADM is used mainly for lower pole coverage and the shaping of a new breast. It helps control the positioning of the implant in the inframammary fold, and prevent the formation of contractile pseudocapsule around the breast implant. In this study, we provide a comprehensive histological description of ADM used for human breast reconstruction over the course of several months following implementation. Using immunohistochemical methods (a panel of 12 antibodies) coupled with optical and transmission electron microscopy, we confirmed that the original acellular dermal matrix became recolonized by fibroblasts and myofibroblasts, and also by various other free cells of the connective tissue (lymphocytes, macrophages and multinucleated giant cells, granulocytes, mast cells) after implantation into the patient's body. Within the implanted ADM, there was a relatively rapid ingrowth of blood vessels. Lymphatic vessels were only detected in one case 9 months after the implantation of the ADM. These results suggest that lymphangiogenesis is a longer process than angiogenesis.

  18. Laser welding and syncristallization techniques comparison: “Ex vivo” study

    PubMed Central

    Meleti, Marco; Vescovi, Paolo; Merigo, Elisabetta; Rocca, Jean-Paul

    2013-01-01

    Background and aims: Stabilization of implant abutments through electric impulses at high voltage for a very short time (electrowelding) was developed in the Eighties. In 2009, the same procedure was performed through the use of laser (laser welding) The aim of this study is to compare electrowelding and laser welding for intra-oral implant abutments stabilization on “ex vivo models” (pig jaws). Materials and methods: Six bars were welded with two different devices (Nd:YAG laser and Electrowelder) to eighteen titanium implant abutment inserted in three pig jaws. During the welding process, thermal increase was recorded, through the use of k-thermocouples, in the bone close to the implants. The strength of the welded joints was evaluated by a traction test after the removal of the implants. For temperature measurements a descriptive analysis and for traction test “values unpaired t test with Welch's correction” were performed: the significance level was set at P<0.05. Results: Laser welding gives a lower thermal increase than Electrowelding at the bone close to implants (Mean: 1.97 and 5.27); the strength of laser welded joints was higher than that of Electrowelding even if nor statistically significant. (Mean: 184.75 and 168.29) Conclusion: Electrowelding seems to have no advantages, in term of thermal elevation and strength, while laser welding may be employed to connect titanium implants for immediate load without risks of thermal damage at surrounding tissues. PMID:24511205

  19. 10-year prospective cohort follow-up of immediately restored XiVE implants.

    PubMed

    Degidi, Marco; Nardi, Diego; Piattelli, Adriano

    2016-06-01

    The aim of this prospective cohort study was to assess the ten-year performance of the condensing thread, self-tapping apex and internal hexagonal connection XiVE implant supporting partial fixed prostheses placed with an immediate restoration approach. All patients received a fixed two- to four-unit partial provisional restoration supported by immediately loaded implants. The final gold alloy/ceramic restorations were cemented approximately 28 weeks after implant insertion. Marginal bone level, pocket probing depth and percentage of bleeding on probing, biological or technical complications and any other adverse events were measured annually up to ten years after surgery. The overall success and survival rates at implant level were evaluated following the International Congress of Oral Implantologists (ICOI) Pisa Consensus Conference criteria. Implant placement in post-extractive or healed sites, smoking and a history of periodontal treatment were evaluated to assess whether they had an influence on bone resorption or on implant survival. Of 114 patients, for a total of 284 implants, fulfilled all the inclusion criteria and were enrolled in the study. 78 (27.5%) implants placed in 30 (26.3%) patients were lost to follow-up. Eight of 284 (2.8%) implants failed in 8 of 114 (7.0%) patients: one (12.5% of losses) due to failure to achieve osseointegration and seven (87.5% of losses) due to peri-implantitis. No cluster implant failures were assessed. The failure of the implant caused the failure of the prosthesis due to the strategic position of the implant in four patients. At the final ten-year follow-up, 121 (61.4%) implants exhibited a "full success" status with an optimal health condition, 21 (10.9%) implants scored a "satisfactory survival" condition, while 49 (25.49%) of the implants were classified as "compromised survival" status (Misch et al. 2008). Smoking was found to be statistically associated with "implant failure" (P = 0.010), while no association was found for patients treated for periodontal disease (P = 0.679) and post-extractive surgical sites (P = 0.664). Statistically significant more marginal bone loss was found in patients treated for periodontal disease (P < 0.0001). An increased bone loss was also observed in smokers, but the difference with the non-smokers was not statistically significant (P = 0.06). The XiVE implants can be successfully used to support immediate prosthesis. Patients with a history of periodontitis show increased bone loss and risk to develop peri-implant disease. Smoking seems to jeopardize the long-term implant survival. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. 76 FR 11414 - Defense Federal Acquisition Regulation Supplement; Independent Research and Development Technical...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-02

    ... Acquisition Regulation Supplement; Independent Research and Development Technical Descriptions (DFARS Case... (DFARS) to require contractors to report independent research and development (IR&D) projects generating... the address shown below on or before May 2, 2011, to be considered in the formation of the final rule...

  1. Student Flow Model SFM-IA: System Documentation. Technical Report 41B. Preliminary Edition.

    ERIC Educational Resources Information Center

    Busby, John C.; Johnson, Richard S.

    Technical specifications, operating procedures, and reference information for the National Center for Higher Education Management Systems' (NCHEMS) Student Flow Model (SFM) computer programs are presented. Included are narrative descriptions of the system and its modules, specific program documentation for each of the modules, system flowcharts,…

  2. Project DIVIDE Instrument Development. Technical Report # 0810

    ERIC Educational Resources Information Center

    Ketterlin-Geller, Leanne; Jung, Eunju; Geller, Josh; Yovanoff, Paul

    2008-01-01

    In this technical report, we describe the development of cognitive diagnostic test items that form the basis of the diagnostic system for Project DIVIDE (Dynamic Instruction Via Individually Designed Environments). The construct underlying the diagnostic test is division of fractions. We include a description of the process we used to identify the…

  3. 10 CFR 52.17 - Contents of applications; technical information.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... NUCLEAR POWER PLANTS Early Site Permits § 52.17 Contents of applications; technical information. (a) For..., and thermal power level of the facilities, or range of possible facilities, for which the site may be... forth the requirements for quality assurance programs for nuclear power plants. The description of the...

  4. 10 CFR 52.17 - Contents of applications; technical information.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... NUCLEAR POWER PLANTS Early Site Permits § 52.17 Contents of applications; technical information. (a) For..., and thermal power level of the facilities, or range of possible facilities, for which the site may be... forth the requirements for quality assurance programs for nuclear power plants. The description of the...

  5. 10 CFR 52.17 - Contents of applications; technical information.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... NUCLEAR POWER PLANTS Early Site Permits § 52.17 Contents of applications; technical information. (a) For..., and thermal power level of the facilities, or range of possible facilities, for which the site may be... forth the requirements for quality assurance programs for nuclear power plants. The description of the...

  6. 10 CFR 52.17 - Contents of applications; technical information.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... NUCLEAR POWER PLANTS Early Site Permits § 52.17 Contents of applications; technical information. (a) For..., and thermal power level of the facilities, or range of possible facilities, for which the site may be... forth the requirements for quality assurance programs for nuclear power plants. The description of the...

  7. Vocational-Technical Marine Career Opportunities in Texas.

    ERIC Educational Resources Information Center

    Hollin, Dewayne

    Presented are background information and descriptions of jobs in various Texas marine industries, as well as a summary of the training required for particular positions. Since the emphasis is upon vocational-technical training for immediate job placement, most opportunities discussed require a high school diploma and some on-the-job education.…

  8. Apprenticeship and CETA Technical Assistance Guide.

    ERIC Educational Resources Information Center

    Employment and Training Administration (DOL), Washington, DC.

    Intended to encourage CETA (Comprehensive Employment and Training Act) prime sponsors and apprenticeship program sponsors to integrate their activities, this technical assistance guide demonstrates many ways the two can unite at the local level to train and place people for employment. A general description of CETA is provided explaining the shift…

  9. Technical assessment of PSSC-supported experiments and demonstrations

    NASA Technical Reports Server (NTRS)

    1978-01-01

    A description of CTS and ATS short-term and long-term satellite demonstration supported through usage of a satellite communication ground station complex is presented. User assessments about the programmatic impact of their demonstrations and experiments were summarized. The technical planning and coordination process involved in satellite utilization is also presented.

  10. 76 FR 31356 - Notice of Proposed Information Collection for Public Comment; Technical Assistance Experience...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-31

    ... Matrices AGENCY: Office of the Community Planning and Development. ACTION: Notice of proposed information..., Expertise, and Awards Received Matrices. Description of the need for the information proposed: The Technical Assistance Experience, Expertise, and Awards Received Matrices will allow the Office of Special Needs...

  11. 47 CFR 22.401 - Description and purposes of developmental authorizations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... technical suitability of antenna locations for stations in the Public Mobile Services; (b) Experimentation leading to the potential development of a new Public Mobile Service or technology; or, (c) Stations... CARRIER SERVICES PUBLIC MOBILE SERVICES Developmental Authorizations § 22.401 Description and purposes of...

  12. Minnesota Department of Education Agricultural Education Program Descriptions 01.0000-01.9095

    ERIC Educational Resources Information Center

    Minnesota Department of Education, 2004

    2004-01-01

    This document provides a brief compilation of descriptions of agricultural education programs linked to Career and Technical Education (CTE) initiative in Minnesota. Agriculture Exploration courses focus on the animal sciences, plant sciences, natural resource sciences, agricultural business and marketing, and leadership development. Agribusiness…

  13. Bottlenecks to clinical translation of direct brain-computer interfaces.

    PubMed

    Serruya, Mijail D

    2014-01-01

    Despite several decades of research into novel brain-implantable devices to treat a range of diseases, only two-cochlear implants for sensorineural hearing loss and deep brain stimulation for movement disorders-have yielded any appreciable clinical benefit. Obstacles to translation include technical factors (e.g., signal loss due to gliosis or micromotion), lack of awareness of current clinical options for patients that the new therapy must outperform, traversing between federal and corporate funding needed to support clinical trials, and insufficient management expertise. This commentary reviews these obstacles preventing the translation of promising new neurotechnologies into clinical application and suggests some principles that interdisciplinary teams in academia and industry could adopt to enhance their chances of success.

  14. Ultrasound and Fluoroscopy-Guided Placement of Central Venous Ports via Internal Jugular Vein: Retrospective Analysis of 1254 Port Implantations at a Single Center

    PubMed Central

    Ahn, Se Jin; Chung, Jin Wook; An, Sang Bu; Yin, Yong Hu; Jae, Hwan Jun; Park, Jae Hyung

    2012-01-01

    Objective To assess the technical success and complication rates of the radiologic placement of central venous ports via the internal jugular vein. Materials and Methods We retrospectively reviewed 1254 central venous ports implanted at our institution between August 2002 and October 2009. All procedures were guided by using ultrasound and fluoroscopy. Catheter maintenance days, technical success rates, peri-procedural, as well as early and late complication rates were evaluated based on the interventional radiologic reports and patient medical records. Results A total of 433386 catheter maintenance days (mean, 350 days; range 0-1165 days) were recorded. The technical success rate was 99.9% and a total of 61 complications occurred (5%), resulting in a post-procedural complication rate of 0.129 of 1000 catheter days. Among them, peri-procedural complications within 24 hours occurred in five patients (0.4%). There were 56 post-procedural complications including 24 (1.9%, 0.055 of 1000 catheter days) early and 32 (2.6%, 0.074 of 1000 catheter days) late complications including, infection (0.6%, 0.018 of 10000 catheter days), thrombotic malfunction (1.4%, 0.040 of 1000 catheter days), nonthrombotic malfunction (0.9%, 0.025 of 1000 catheter days), venous thrombosis (0.5%, 0.014 of 1000 catheter days), as well as wound problems (1.1%, 0.032 of 1000 catheter days). Thirty six CVPs (3%) were removed due to complications. Bloodstream infections and venous thrombosis were the two main adverse events prolonging hospitalization (mean 13 days and 5 days, respectively). Conclusion Radiologic placement of a central venous port via the internal jugular vein is safe and efficient as evidenced by its high technical success rate and a very low complication rate. PMID:22563269

  15. A novel aragonite-based scaffold for osteochondral regeneration: early experience on human implants and technical developments.

    PubMed

    Kon, Elizaveta; Robinson, Dror; Verdonk, Peter; Drobnic, Matej; Patrascu, Jenel Mariano; Dulic, Oliver; Gavrilovic, Gordon; Filardo, Giuseppe

    2016-12-01

    Chondral and osteochondral lesions represent a debilitating disease. Untreated lesions remain a risk factor for more extensive joint damage. The objective of this clinical study is to evaluate safety and early results of an aragonite-based scaffold used for osteochondral unit repair, by analysing both clinical outcome and MRI results, as well as the benefits of the procedure optimization through novel tapered shaped implants. A crystalline aragonite bi-phasic scaffold was implanted in patients affected by focal chondral-osteochondral knee lesions of the condyle and trochlea. Twenty-one patients (17 men, 4 women with a mean age of 31.0 ± 8.6 years) without severe OA received tapered shaped implants for the treatment of 2.5 ±1.7 cm 2 sized defects. The control group consisted of 76 patients selected according to the same criteria from a database of patients who previously underwent implantation of cylindrical-shaped implants. The clinical outcome of all patients was evaluated with the IKDC subjective score, the Lysholm score, and all 5 KOOS subscales administered preoperatively and at 6 and 12 months after surgery, while MRI evaluation was performed at the 12 month follow-up. A statistically significant improvement in all clinical scores was documented both in the tapered implants and the cylindrical group. No difference could be detected in the comparison between the improvement obtained with the two implant types, neither in the clinical nor in imaging evaluations. A difference could be detected instead in terms of revision rate, which was lower in the tapered implant group with no implant removal - 0% vs 8/76-10.5% failures in the cylindrical implants. This study highlighted both safety and potential of a novel aragonite-based scaffold for the treatment of chondral and osteochondral lesions in humans. A tapered shape relative to the cylindrical shaped implant design, improved the scaffold's safety profile. Tapered scaffolds maintain the clinical improvement observed in cylindrical implants while reducing the postoperative risk of revision surgery. This aragonite-based implant was associated with a significant clinical improvement at the 12 month follow-up. Moreover, MRI findings revealed graft integration with good bone and cartilage formation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Implanting a Discipline: The Academic Trajectory of Nuclear Engineering in the USA and UK

    ERIC Educational Resources Information Center

    Johnston, Sean F.

    2009-01-01

    The nuclear engineer emerged as a new form of recognised technical professional between 1940 and the early 1960s as nuclear fission, the chain reaction and their applications were explored. The institutionalization of nuclear engineering--channelled into new national laboratories and corporate design offices during the decade after the war, and…

  17. The use of light/chemically hardened polymethylmethacrylate, polyhydroxylethylmethacrylate, and calcium hydroxide graft material in combination with polyanhydride around implants and extraction sockets in minipigs: Part II: histologic and micro-CT evaluations.

    PubMed

    Hasturk, Hatice; Kantarci, Alpdogan; Ghattas, Mazen; Dangaria, Smit J; Abdallah, Rima; Morgan, Elise F; Diekwisch, Thomas G H; Ashman, Arthur; Van Dyke, Thomas

    2014-09-01

    This report is the second part of the previously published study on the impact of light/chemical hardening technology and a newly formulated composite graft material for crestal augmentation during immediate implant placement. A total of 48 implants were placed into the sockets of the mesial roots of freshly extracted mandibular premolar teeth in three minipigs. Crestal areas and intrabony spaces were randomly augmented with light-hardened graft materials including a composite graft consisting of polymethylmethacrylate, polyhydroxylethylmethacrylate, and calcium hydroxide (PPCH) plus polyanhydride (PA); PPCH graft; and PA graft, or left untreated. Distal sockets not receiving implants and the sockets of first molars (n = 60) were randomly treated with one of the graft materials or left empty. In addition, two molar sockets were treated with the original PPCH graft material. Quantitative microcomputed tomography (micro-CT) was used to assess alveolar bone structure and tissue compositions. Histologic evaluations included descriptive histology to assess the peri-implant wound healing, as well as histomorphometric measurements to determine bone-to-implant contact (BIC). Both trabecular and cortical bone measurements by micro-CT did not reveal any significant differences among the groups. Sites augmented with PPCH+PA resulted in significantly greater BIC surface than PPCH alone and no-graft-treated implants (P <0.05) histologically. Stained ground sections showed complete bone formation between bone and implant surface in the PPCH+PA group, whereas sites without augmentation showed large gaps between bone and implant surfaces, indicating a slower bone apposition and less BIC surface compared to all other groups. Similar to implant sections, all materials showed positive outcome on trabecular and cortical bone formation in extraction sockets with an intact crestal cortical bone. Histologic evaluations supported the previous findings on implant stability and function and confirmed that PPCH+PA provides a greater BIC with a well-organized implant-bone interface and is useful in crestal augmentation during immediate implant placement.

  18. Reporting quality of randomised controlled trials published in prosthodontic and implantology journals.

    PubMed

    Kloukos, D; Papageorgiou, S N; Doulis, I; Petridis, H; Pandis, N

    2015-12-01

    The purpose of this study was to examine the reporting quality of randomised controlled trials (RCTs) published in prosthodontic and implantology journals. Thirty issues of nine journals in prosthodontics and implant dentistry were searched for RCTs, covering the years 2005-2012: The Journal of Prosthetic Dentistry, Journal of Oral Rehabilitation, The International Journal of Prosthodontics, The International Journal of Periodontics & Restorative Dentistry, Clinical Oral Implants Research, Clinical Implant Dentistry & Related Research, The International Journal of Oral & Maxillofacial Implants, Implant Dentistry and Journal of Dentistry. The reporting quality was assessed using a modified Consolidated Standards of Reporting Trials (CONSORT) statement checklist. Data were analysed using descriptive statistics followed by univariable and multivariable examination of statistical associations (α = 0·05). A total of 147 RCTs were identified with a mean CONSORT score of 69·4 (s.d. = 9·7). Significant differences were found among journals with the Journal of Oral Rehabilitation achieving the highest score (80·6, s.d. = 5·5) followed by Clinical Oral Implants Research (73·7, s.d. = 8·3). Involvement of a statistician/methodologist was significantly associated with increased CONSORT scores. Overall, the reporting quality of RCTs in major prosthodontic and implantology journals requires improvement. This is of paramount importance considering that optimal reporting of RCTs is an important prerequisite for clinical decision-making. © 2015 John Wiley & Sons Ltd.

  19. Treatment of articular cartilage lesions of the knee by microfracture or autologous chondrocyte implantation: a systematic review.

    PubMed

    Oussedik, Sam; Tsitskaris, Konstantinos; Parker, David

    2015-04-01

    We performed a systematic review of the treatment of articular cartilage lesions of the knee by microfracture or autologous chondrocyte implantation to determine the differences in patient outcomes after these procedures. We searched PubMed/Medline, Embase, and The Cochrane Library databases in the period from January 10 through January 20, 2013, and included 34 articles in our qualitative analysis. All studies showed improvement in outcome scores in comparison with baseline values, regardless of the treatment modality. The heterogeneity of the results presented in the studies precluded a meta-analysis. Microfracture appears to be effective in smaller lesions and is usually associated with a greater proportion of fibrocartilage production, which may have an effect on durability and eventual failure. Autologous chondrocyte implantation is an effective treatment that may result in a greater proportion of hyaline-like tissue at the repair site, which may in turn have a beneficial effect on durability and failure; it appears to be effective in larger lesions. Autologous chondrocyte implantation with periosteum has been shown to be associated with symptomatic cartilage hypertrophy more frequently than autologous chondrocyte implantation with collagen membrane. Matrix-associated autologous chondrocyte implantation is technically less challenging than the other techniques available, and in lesions greater than 4 cm(2), it has been shown to be more effective than microfracture. Level IV, systematic review of Level I-IV studies. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  20. Multi-scale, multi-modal analysis uncovers complex relationship at the brain tissue-implant neural interface: new emphasis on the biological interface

    NASA Astrophysics Data System (ADS)

    Michelson, Nicholas J.; Vazquez, Alberto L.; Eles, James R.; Salatino, Joseph W.; Purcell, Erin K.; Williams, Jordan J.; Cui, X. Tracy; Kozai, Takashi D. Y.

    2018-06-01

    Objective. Implantable neural electrode devices are important tools for neuroscience research and have an increasing range of clinical applications. However, the intricacies of the biological response after implantation, and their ultimate impact on recording performance, remain challenging to elucidate. Establishing a relationship between the neurobiology and chronic recording performance is confounded by technical challenges related to traditional electrophysiological, material, and histological limitations. This can greatly impact the interpretations of results pertaining to device performance and tissue health surrounding the implant. Approach. In this work, electrophysiological activity and immunohistological analysis are compared after controlling for motion artifacts, quiescent neuronal activity, and material failure of devices in order to better understand the relationship between histology and electrophysiological outcomes. Main results. Even after carefully accounting for these factors, the presence of viable neurons and lack of glial scarring does not convey single unit recording performance. Significance. To better understand the biological factors influencing neural activity, detailed cellular and molecular tissue responses were examined. Decreases in neural activity and blood oxygenation in the tissue surrounding the implant, shift in expression levels of vesicular transporter proteins and ion channels, axon and myelin injury, and interrupted blood flow in nearby capillaries can impact neural activity around implanted neural interfaces. Combined, these tissue changes highlight the need for more comprehensive, basic science research to elucidate the relationship between biology and chronic electrophysiology performance in order to advance neural technologies.

  1. iPod touch-assisted instrumentation of the spine: a technical report.

    PubMed

    Jost, Gregory F; Bisson, Erica F; Schmidt, Meic H

    2013-12-01

    Instrumentation of the spine depends on choosing the correct insertion angles to implant screws. Although modern image guidance facilitates precise instrumentation of the spine, the equipment is costly and availability is limited. Although most surgeons use lateral fluoroscopy to guide instrumentation in the sagittal plane, the lateromedial angulation is often chosen by estimation. To overcome the associated uncertainty, iPod touch-based applications for measuring angles can be used to assist with screw implantation. To evaluate the use of the iPod touch to adjust instruments to the optimal axial insertion angle for placement of pedicle screws in the lumbar spine. Twenty lumbar pedicle screws in 5 consecutive patients were implanted using the iPod touch. The lateromedial angulation was measured on preoperative images and reproduced in the operative field with the iPod touch. The instruments to implant the screws were aligned with the side of the iPod for screw insertion. Actual screw angles were remeasured on postoperative imaging. We collected demographic, clinical, and operative data for each patient. In 16 of 20 screws, the accuracy of implantation was within 3 degrees of the ideal trajectory. The 4 screws with an angle mismatch of 7 to 13 degrees were all implanted at the caudal end of the exposure, where maintaining the planned angulation was impeded by strong muscles pushing medially. iPod touch-assisted instrumentation of the spine is a very simple technique, which, in combination with a lateral fluoroscopy, may guide placement of pedicle screws in the lumbar spine.

  2. Return of the cadaver: Key role of anatomic dissection for plastic surgery resident training.

    PubMed

    Krähenbühl, Swenn Maxence; Čvančara, Paul; Stieglitz, Thomas; Bonvin, Raphaël; Michetti, Murielle; Flahaut, Marjorie; Durand, Sébastien; Deghayli, Lina; Applegate, Lee Ann; Raffoul, Wassim

    2017-07-01

    Successful Plastic Surgery Residency training is subjected to evolving society pressure of lower hourly work weeks imposed by external committees, labor laws, and increased public awareness of patient care quality. Although innovative measures for simulation training of surgery are appearing, there is also the realization that basic anatomy training should be re-enforced and cadaver dissection is of utmost importance for surgical techniques.In the development of new technology for implantable neurostimulatory electrodes for the management of phantom limb pain in amputee patients, a design of a cadaveric model has been developed with detailed steps for innovative transfascicular insertion of electrodes. Overall design for electrode and cable implantation transcutaneous was established and an operating protocol devised.Microsurgery of the nerves of the upper extremities for interfascicular electrode implantation is described for the first time. Design of electrode implantation in cadaver specimens was adapted with a trocar delivery of cables and electrodes transcutaneous and stabilization of the electrode by suturing along the nerve. In addition, the overall operating arena environment with specific positions of the multidisciplinary team necessary for implantable electrodes was elaborated to assure optimal operating conditions and procedures during the organization of a first-in-man implantation study.Overall importance of plastic surgery training for new and highly technical procedures is of importance and particularly there is a real need to continue actual cadaveric training due to patient variability for nerve anatomic structures.

  3. State Competencies for Writing: Grades K-6. Technical Note.

    ERIC Educational Resources Information Center

    Lawlor, Joseph

    This paper contains descriptions of mandated minimum competency documents from seven states: Florida, Georgia, Louisiana, Michigan, Oklahoma, Tennessee, and Texas. Each description provides a picture of the general nature of the state requirements and a discussion of the specific writing skills requirements. The procedures used to compile a…

  4. State Minimum Competencies for High School Graduation. Technical Note.

    ERIC Educational Resources Information Center

    Lawlor, Joseph

    This paper contains descriptions of mandated minimum competency programs in 13 states: Connecticut, Delaware, Georgia, Hawaii, Idaho, Kansas, Missouri, New Jersey, New York, North Carolina, South Carolina, Texas, and Vermont. Each description provides the skills assessed in the state, the assessment instruments used, and the overall purposes of…

  5. 40 CFR 161.160 - Description of materials used to produce the product.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Chemistry Data Requirements § 161.160 Description of materials used to produce the product. The following... composition (and, if requested by the Agency, chemical and physical properties) of the ingredient, including a..., chemical or physical properties) of the starting material, including a copy of all technical specifications...

  6. 40 CFR 161.160 - Description of materials used to produce the product.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Chemistry Data Requirements § 161.160 Description of materials used to produce the product. The following... composition (and, if requested by the Agency, chemical and physical properties) of the ingredient, including a..., chemical or physical properties) of the starting material, including a copy of all technical specifications...

  7. 40 CFR 161.160 - Description of materials used to produce the product.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Chemistry Data Requirements § 161.160 Description of materials used to produce the product. The following... composition (and, if requested by the Agency, chemical and physical properties) of the ingredient, including a..., chemical or physical properties) of the starting material, including a copy of all technical specifications...

  8. 40 CFR 161.160 - Description of materials used to produce the product.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Chemistry Data Requirements § 161.160 Description of materials used to produce the product. The following... composition (and, if requested by the Agency, chemical and physical properties) of the ingredient, including a..., chemical or physical properties) of the starting material, including a copy of all technical specifications...

  9. Technical information report: Plasma melter operation, reliability, and maintenance analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hendrickson, D.W.

    1995-03-14

    This document provides a technical report of operability, reliability, and maintenance of a plasma melter for low-level waste vitrification, in support of the Hanford Tank Waste Remediation System (TWRS) Low-Level Waste (LLW) Vitrification Program. A process description is provided that minimizes maintenance and downtime and includes material and energy balances, equipment sizes and arrangement, startup/operation/maintence/shutdown cycle descriptions, and basis for scale-up to a 200 metric ton/day production facility. Operational requirements are provided including utilities, feeds, labor, and maintenance. Equipment reliability estimates and maintenance requirements are provided which includes a list of failure modes, responses, and consequences.

  10. Monitoring the evolution of boron doped porous diamond electrode on flexible retinal implant by OCT and in vivo impedance spectroscopy.

    PubMed

    Hébert, Clément; Cottance, Myline; Degardin, Julie; Scorsone, Emmanuel; Rousseau, Lionel; Lissorgues, Gaelle; Bergonzo, Philippe; Picaud, Serge

    2016-12-01

    Nanocrystalline Boron doped Diamond proved to be a very attractive material for neural interfacing, especially with the retina, where reduce glia growth is observed with respect to other materials, thus facilitating neuro-stimulation over long terms. In the present study, we integrated diamond microelectrodes on a polyimide substrate and investigated their performances for the development of neural prosthesis. A full description of the microfabrication of the implants is provided and their functionalities are assessed using cyclic voltammetry and electrochemical impedance spectroscopy. A porous structure of the electrode surface was thus revealed and showed promising properties for neural recording or stimulation. Using the flexible implant, we showed that is possible to follow in vivo the evolution of the electric contact between the diamond electrodes and the retina over 4months by using electrochemical impedance spectroscopy. The position of the implant was also monitored by optical coherence tomography to corroborate the information given by the impedance measurements. The results suggest that diamond microelectrodes are very good candidates for retinal prosthesis. Copyright © 2016. Published by Elsevier B.V.

  11. The "beauty arch: " a new aesthetic analysis for malar augmentation planning.

    PubMed

    Marianetti, Tito Matteo; Cozzolino, Salvatore; Torroni, Andrea; Gasparini, Giulio; Pelo, Sandro

    2015-05-01

    Midface is a critical area for the aesthetics of the face. Despite malar hypoplasia is often combined with a class III malocclusion, there are few studies focusing on the results of a combined approach of malar implants and Le Fort I. We describe a new aesthetic analysis, named "beauty arch" analysis, for the assessment of sagittal projection of the malar region. We took a reference group of 74 Italian women participating in a national beauty contest in 2011 on which we performed our analysis. We used the ideal values to elaborate the surgical treatment planning of a second group of 45 consecutive female patients affected by skeletal class III malocclusion.Twenty-three patients undergo simultaneous Le Fort I osteotomy and malar implants. From the descriptive statistical comparison of the patients' values before and after orthognathic surgery and malar implants with the reference values, we observed how all parameters considered got closer to the ideal population. We consider our beauty arch a useful help for surgeon in the treatment planning of patients with skeletal malocclusions and malar implants.

  12. Children with a cochlear implant: characteristics and determinants of speech recognition, speech-recognition growth rate, and speech production.

    PubMed

    Wie, Ona Bø; Falkenberg, Eva-Signe; Tvete, Ole; Tomblin, Bruce

    2007-05-01

    The objectives of the study were to describe the characteristics of the first 79 prelingually deaf cochlear implant users in Norway and to investigate to what degree the variation in speech recognition, speech- recognition growth rate, and speech production could be explained by the characteristics of the child, the cochlear implant, the family, and the educational setting. Data gathered longitudinally were analysed using descriptive statistics, multiple regression, and growth-curve analysis. The results show that more than 50% of the variation could be explained by these characteristics. Daily user-time, non-verbal intelligence, mode of communication, length of CI experience, and educational placement had the highest effect on the outcome. The results also indicate that children educated in a bilingual approach to education have better speech perception and faster speech perception growth rate with increased focus on spoken language.

  13. CUTANEOUS SQUAMOUS CELL CARCINOMA IN A PANTHER CHAMELEON (FURCIFER PARDALIS) AND TREATMENT WITH CARBOPLATIN IMPLANTABLE BEADS.

    PubMed

    Johnson, James G; Naples, Lisa M; Chu, Caroline; Kinsel, Michael J; Flower, Jennifer E; Van Bonn, William G

    2016-09-01

    A 3-yr-old male panther chameleon (Furcifer pardalis) presented with bilateral raised crusted skin lesions along the lateral body wall that were found to be carcinoma in situ and squamous cell carcinoma. Similar lesions later developed on the caudal body wall and tail. A subcutaneous implantable carboplatin bead was placed in the first squamous cell carcinoma lesion identified. Additional new lesions sampled were also found to be squamous cell carcinomas, and viral polymerase chain reaction was negative for papillomaviruses and herpesviruses. Significant skin loss would have resulted from excision of all the lesions, so treatment with only carboplatin beads was used. No adverse effects were observed. Lesions not excised that were treated with beads decreased in size. This is the first description of cutaneous squamous cell carcinoma and treatment with carboplatin implantable beads in a panther chameleon.

  14. Technical books and monographs. 1979 compilation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This booklet lists technical books and monographs published since the issuance of Technical Books and Monographs, 1978 Catalog, a bibliography of books and monographs sponsored by the US Department of Energy (DOE) or by one of the earlier organizations that were brought together to form DOE. In general, information for each published book, and for each book in press when known, includes title, author and author affiliation, publisher and publication date, page count, size of book, price, availability information if the book is not available from the publisher, Library of Congress card number, International Standard Book Number (ISBN), a briefmore » descriptive statement concerning the book, and a list or a description of the contents. The books and monographs are grouped under twelve subject categories: general reference, biology and medicine, chemistry, computers and mathematics, energy, engineering and instrumentation, environment, health and safety, isotope separation, metallurgy and materials, physics, and reactors. (RWR)« less

  15. Clinical and Radiographic Assessment of Three-Implant-Supported Fixed-Prosthesis Rehabilitation of the Edentulous Mandible: Immediate Versus Delayed Loading.

    PubMed

    Primo, Bruno Tochetto; Mezzari, Leonardo Marcos; da Fontoura Frasca, Luís Carlos; Linderman, Raquel; Rivaldo, Elken Gomes

    To evaluate and compare the clinical and radiographic outcomes of mandibular rehabilitation with fixed prostheses on three implants with immediate versus delayed loading. The sample comprised 21 patients who underwent treatment with immediate loading and 23 who received delayed loading. All had worn their prostheses for at least 18 months. Radiographic evaluation of bone loss was carried out in Adobe Photoshop CS5 by a single calibrated examiner using digitized panoramic radiographs. Clinical examination of the technical conditions of the prosthetic device assessed the condition of the acrylic resin base, dental occlusion, metal framework, presence of cover screws, screw fixation of the prosthesis and abutments, length of cantilever (effort) and resistance arms, presence of plaque on prosthetic abutments, and hygiene of the prosthesis. One implant failed in each group, resulting in a 95.23% treatment success rate with immediate loading and 95.65% with delayed loading (no statistically significant between-group difference). In the immediate-loading group, the mean bone loss was 1.96 ± 0.73 mm around central implants and 1.64 ± 0.84 mm at distal implants. In the delayed-loading group, the mean bone loss was 1.85 ± 0.67 mm around central implants and 1.70 ± 0.77 mm at distal implants. According to Student t test, there was no significant within-group difference in bone loss and no difference between the immediate-loading and delayed-loading groups. The only prosthesis-related complications that differed significantly between groups were "condition of the acrylic base," "occlusion," and "presence of right cover screw." There was no statistically significant association of lever arm ratio with peri-implant bone loss or bone loss on the mesial surfaces compared to the distal surfaces of the distal implants. The three-implant-supported fixed prosthesis protocol tested in this study proved to be a viable therapeutic strategy for mandibular edentulous patients with maxillary complete dentures, regardless of whether loading was immediate or delayed, with no difference in peri-implant bone loss.

  16. Single dental implant retained mandibular complete dentures – influence of the loading protocol: study protocol for a randomized controlled trial

    PubMed Central

    2014-01-01

    Background Over the years, there has been a strong consensus in dentistry that at least two implants are required to retain a complete mandibular denture. It has been shown in several clinical trials that one single median implant can retain a mandibular overdenture sufficiently well for up to 5 years without implant failures, when delayed loading was used. However, other trials have reported conflicting results with in part considerable failure rates when immediate loading was applied. Therefore it is the purpose of the current randomized clinical trial to test the hypothesis that immediate loading of a single mandibular midline implant with an overdenture will result in a comparable clinical outcome as using the standard protocol of delayed loading. Methods/design This prospective nine-center randomized controlled clinical trial is still ongoing. The final patient will complete the trial in 2016. In total, 180 edentulous patients between 60 and 89 years with sufficient complete dentures will receive one median implant in the edentulous mandible, which will retain the existing complete denture using a ball attachment. Loading of the median implant is either immediately after implant placement (experimental group) or delayed by 3 months of submerged healing at second-stage surgery (control group). Follow-up of patients will be performed for 24 months after implant loading. The primary outcome measure is non-inferiority of implant success rate of the experimental group compared to the control group. The secondary outcome measures encompass clinical, technical and subjective variables. The study was funded by the Deutsche Forschungsgemeinschaft (German research foundation, KE 477/8-1). Discussion This multi-center clinical trial will give information on the ability of a single median implant to retain a complete mandibular denture when immediately loaded. If viable, this treatment option will strongly improve everyday dental practice. Trial registration The trial has been registered at Deutsches Register Klinischer Studien (German register of clinical trials) under DRKS-ID: DRKS00003730 since 23 August 2012. (http://www.germanctr.de). PMID:24884848

  17. BIOPHYSICAL EVALUATION OF INDIVIDUAL COMPONENT LEVELS AND SELECTED CONFIGURATIONS OF THE UNITED STATES MARINE CORPS COLD-WEATHER CLOTHING ENSEMBLE

    DTIC Science & Technology

    2018-01-02

    TECHNICAL REPORT NO. T18-01 DATE January 2018 BIOPHYSICAL EVALUATION OF INDIVIDUAL COMPONENT...USARIEM TECHNICAL REPORT T18-01 BIOPHYSICAL EVALUATION OF INDIVIDUAL COMPONENT LEVELS AND...OF TABLES Table Page Table 1. Clothing and individual equipment descriptions ................................................. 3 Table 2. Surface

  18. Local/State Bilingual Project. 1981-82 Final Technical Report. Appendixes.

    ERIC Educational Resources Information Center

    Austin Independent School District, TX. Office of Research and Evaluation.

    The 1981-82 Local/State Bilingual Program Technical Report addresses the evaluation questions of the Local/State Bilingual Program Evaluation Design. It is organized into six appendixes. Each appendix reports the information collected by a specific measure. Each appendix consists of (1) an instrument description, (2) purpose of the measure, (3)…

  19. From Industry to Teaching: The Quality Instruction Program at Hocking Technical College.

    ERIC Educational Resources Information Center

    Moran, Ralph; And Others

    This presentation on Hocking Technical College's (HTC's) Quality Instruction Program (QIP) provides a program description and comments from three HTC faculty members who have been involved in the program in various ways. Recognizing that many faculty members are hired on the basis of their industrial credentials rather than their teaching…

  20. Financing Options for Home Care for Children with Chronic Illness and Severe Disability. Technical Assistance Manual.

    ERIC Educational Resources Information Center

    Ellison, Marsha Langer; And Others

    This manual is intended to accompany technical assistance efforts aimed at improving selected states' home health care programs for children with chronic illness and severe disability. Summary descriptions of funding sources are presented, including purpose, eligibility guidelines, and services covered, as well as additional information as…

  1. Technical Notes on the Multifactor Method of Elementary School Closing.

    ERIC Educational Resources Information Center

    Puleo, Vincent T.

    This report provides preliminary technical information on a method for analyzing the factors involved in the closing of elementary schools. Included is a presentation of data and a brief discussion bearing on descriptive statistics, reliability, and validity. An intercorrelation matrix is also examined. The method employs 9 factors that have a…

  2. Technical and Vocational Education and Training (TVET): Understanding the Nigerian Experience

    ERIC Educational Resources Information Center

    Dike, Victor Ebipuruonwu

    2013-01-01

    The descriptive mixed-methods study explores and describes the challenges and prospects of the growth and development of technical and vocational education and training (TVET) schools and science-based technology education in Nigeria. It is not understood how Nigerians in the United States perceive the impacts of governmental policies on education…

  3. Accessing technical data bases using STDS: A collection of scenarios

    NASA Technical Reports Server (NTRS)

    Hardgrave, W. T.

    1975-01-01

    A line by line description is given of sessions using the set-theoretic data system (STDS) to interact with technical data bases. The data bases contain data from actual applications at NASA Langley Research Center. The report is meant to be a tutorial document that accompanies set processing in a network environment.

  4. Career-Technical Students in Baccalaureate Programs: Predictors of the Intent to Persist and Satisfaction with Educational Pathways

    ERIC Educational Resources Information Center

    Uranis, Julie

    2015-01-01

    This research explores the intersections of descriptive attributes, expectations, and influences (independent variables) and the degree to which they predict the intent to persist and satisfaction (dependent variables) of students enrolled in career-technical programs at four-year institutions. Little research exists for this population, and…

  5. Brokering Boundaries: Literacy Change Agents at Work

    ERIC Educational Resources Information Center

    VanDeusen-MacLeod, Elizabeth A.

    2009-01-01

    The purpose of this mixed-method descriptive case study is to investigate the role technical assistance providers within the context of one state's large-scale literacy grant program. This study provides an in-depth examination of one state's technical assistance providers known as Reading First Facilitators (RFF) through the study of a group of…

  6. A Critical Review of the Technical Characteristics of Current Preschool Screening Batteries

    ERIC Educational Resources Information Center

    Emmons, Michael R.; Alfonso, Vincent C.

    2005-01-01

    The current review provides a summary and evaluation of the technical characteristics of five preschool screening batteries, including the Brigance Screens, DIAL-3, ESI-R, ESP, and FirstSTEP. These norm-referenced instruments were selected on the basis of their commercial availability, description as a screening instrument, and ability to assess…

  7. 77 FR 53903 - Notice of Proposed Information Collection for Public Comment: OneCPD Technical Assistance and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-04

    ... Information Collection for Public Comment: OneCPD Technical Assistance and Capacity Building Needs Assessment... Needs Assessment. Description of the need for the information proposed: The OneCPD Needs Assessment will... to identify trends in TA needs across grantees and assist in prioritizing the development of tools...

  8. Abstracts of BESRL Research Publications, FY 1969.

    ERIC Educational Resources Information Center

    Brown, Emma E.

    Publications abstracted include Technical Research Reports 1156 and 1157, Technical Research Notes 199 through 210, Research Studies 68-4 through 68-6 and 69-1 through 6910, and Research Memorandums 68-8 through 68-13. Included are descriptions of 19 Work Units covering activities reported in the 33 abstracted publications, a list of regular…

  9. Clinical Considerations of Adapted Drilling Protocol by Bone Quality Perception.

    PubMed

    Toia, Marco; Stocchero, Michele; Cecchinato, Francesca; Corrà, Enrico; Jimbo, Ryo; Cecchinato, Denis

    To evaluate insertion torque value (ITV) and marginal bone loss (MBL) of an implant system after a clinically perceived bone quality-adapted drilling. This multicenter retrospective study included patients treated with implants, conventionally loaded, in completely healed sites. Operators customized the osteotomy preparation according to radiographic assessment and their perception of bone quality. Drilling sequence, bone quality, and ITV were recorded at the time of surgery. Radiographs were taken at the time of implant placement and permanent restoration. MBL between implant placement and permanent restoration was calculated. The implant was used as the statistical unit. Demographic and implant characteristics were shown by means of descriptive statistics. Outcome values were compared using analysis of variance (ANOVA) and Kruskal-Wallis tests. Multiple regression models were used to test the effect of independent variables on ITV and MBL. One hundred eighty-eight implants placed in 87 patients were included in the analysis. The mean observation period was 144 ± 59 days. The mean ITV was 30.8 ± 15.1 Ncm. ITV differed significantly based on arches (mandible/maxilla) (P = .001), bone quality (P < .001), implant diameter (P = .032), and drilling protocol (P = .019). Median MBL was 0.05 mm (0.00; 0.24). A significant difference was found between the mandible and maxilla (P = .008) and between drilling protocols (P = .011). In particular, significantly higher MBL was found in the undersized drilling protocol. Multiple regression analysis showed that ITV was influenced by bone quality and implant diameter. MBL was influenced by bone quality, implant diameter, ITV, and the interaction between bone quality and ITV. It was estimated that MBL was greater with increased bone density and ITV. Excessive ITV in dense bone can cause negative marginal bone responses. A presurgical radiographic assessment and the perception of bone quality are necessary to select an optimal drilling protocol and to minimize surgical trauma.

  10. Off-pump transapical implantation of artificial neo-chordae to correct mitral regurgitation: the TACT Trial (Transapical Artificial Chordae Tendinae) proof of concept.

    PubMed

    Seeburger, Joerg; Rinaldi, Mauro; Nielsen, Sten Lyager; Salizzoni, Stefano; Lange, Ruediger; Schoenburg, Markus; Alfieri, Ottavio; Borger, Michael Andrew; Mohr, Friedrich Wilhelm; Aidietis, Audrius

    2014-03-11

    The goal of this study was to evaluate the safety and performance of the NeoChord DS1000 system (NeoChord, Inc., Minneapolis, Minnesota). There is an increasing interest in transcatheter mitral valve (MV) treatment. The NeoChord DS 1000 system enables off-pump beating heart transapical MV repair with implantation of artificial neo-chordae. Patients with severe mitral regurgitation (MR) due to isolated posterior prolapse were included in this TACT (Transapical Artificial Chordae Tendinae) trial. All patients were scheduled for off-pump transapical implantation of neo-chordae. Thirty patients at 7 centers were enrolled. Major adverse events included 1 death due to post-cardiotomy syndrome and concomitant sepsis and 1 minor stroke with the patient fully recovered at the 30-day follow-up visit. Additional patients experienced procedural major adverse events related to a reoperation or conversion to standard of care. Acute procedural success (placement of at least 1 neo-chord and reduction of MR from 3+ or 4+ to ≤2+) was achieved in 26 patients (86.7%). In 4 patients neo-chordae were not placed for technical and/or patient-specific reasons. These patients underwent intraoperative (3 patients) or post-operative (1 patient) standard MV repair. At 30 days, 17 patients maintained an MR grade ≤2+. Four patients who developed recurrent MR were successfully treated with open MV repair during 30-day follow-up. Results improved with experience: durable reduction in MR to ≤2+ at 30 days was achieved in 5 (33.3%) of the first 15 patients and 12 (85.7%) of the last 14 patients. Off-pump transapical implantation of artificial chordae to correct MR is technically safe and feasible; however, it yields further potential for improvement of efficacy and durability. (Safety and Performance Study of the NeoChord Device [TACT]; NCT01777815). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. A technical evaluation of the Nucletron FIRST system: conformance of a remote afterloading brachytherapy seed implantation system to manufacturer specifications and AAPM Task Group report recommendations.

    PubMed

    Rivard, Mark J; Evans, Dee-Ann Radford; Kay, Ian

    2005-01-01

    The Fully Integrated Real-time Seed Treatment (FIRST) system by Nucletron has been available in Europe since November 2001 and is being used more and more in Canada and the United States. Like the conventional transrectal ultrasound implant procedure, the FIRST system utilizes an ultrasound probe, needles, and brachytherapy seeds. However, this system is unique in that it (1) utilizes a low-dose-rate brachytherapy seed remote afterloader (the seedSelectron), (2) utilizes 3D image reconstruction acquired from electromechanically controlled, nonstepping rotation of the ultrasound probe, (3) integrates the control of a remote afterloader with electromechanical control of the ultrasound probe for integrating the clinical procedure into a single system, and (4) automates the transfer of planning information and seed delivery to improve quality assurance and radiation safety. This automated delivery system is specifically intended to address reproducibility and accuracy of seed positioning during implantation. The FIRST computer system includes two software environments: SPOT PRO and seedSelectron; both are used to facilitate treatment planning and brachytherapy seed implantation from beginning to completion of the entire procedure. In addition to these features, the system is reported to meet certain product specifications for seed delivery positioning accuracy and reproducibility, seed calibration accuracy and reliability, and brachytherapy dosimetry calculations. Consequently, a technical evaluation of the FIRST system was performed to determine adherence to manufacturer specifications and to the American Association of Physicists in Medicine (AAPM) Task Group Reports 43, 53, 56, 59, and 64 and recommendations of the American Brachytherapy Society (ABS). The United States Nuclear Regulatory Commission (NRC) has recently added Licensing Guidance for the seedSelectron system under 10 CFR 35.1000. Adherence to licensing guidance is made by referencing applicable AAPM Task Group recommendations. In general, results of this evaluation indicated that the system met its claimed specifications as well as the applicable recommendations outlined in the AAPM and ABS reports.

  12. Music Perception with Cochlear Implants: A Review

    PubMed Central

    McDermott, Hugh J.

    2004-01-01

    The acceptance of cochlear implantation as an effective and safe treatment for deafness has increased steadily over the past quarter century. The earliest devices were the first implanted prostheses found to be successful in compensating partially for lost sensory function by direct electrical stimulation of nerves. Initially, the main intention was to provide limited auditory sensations to people with profound or total sensorineural hearing impairment in both ears. Although the first cochlear implants aimed to provide patients with little more than awareness of environmental sounds and some cues to assist visual speech-reading, the technology has advanced rapidly. Currently, most people with modern cochlear implant systems can understand speech using the device alone, at least in favorable listening conditions. In recent years, an increasing research effort has been directed towards implant users’ perception of nonspeech sounds, especially music. This paper reviews that research, discusses the published experimental results in terms of both psychophysical observations and device function, and concludes with some practical suggestions about how perception of music might be enhanced for implant recipients in the future. The most significant findings of past research are: (1) On average, implant users perceive rhythm about as well as listeners with normal hearing; (2) Even with technically sophisticated multiple-channel sound processors, recognition of melodies, especially without rhythmic or verbal cues, is poor, with performance at little better than chance levels for many implant users; (3) Perception of timbre, which is usually evaluated by experimental procedures that require subjects to identify musical instrument sounds, is generally unsatisfactory; (4) Implant users tend to rate the quality of musical sounds as less pleasant than listeners with normal hearing; (5) Auditory training programs that have been devised specifically to provide implant users with structured musical listening experience may improve the subjective acceptability of music that is heard through a prosthesis; (6) Pitch perception might be improved by designing innovative sound processors that use both temporal and spatial patterns of electric stimulation more effectively and precisely to overcome the inherent limitations of signal coding in existing implant systems; (7) For the growing population of implant recipients who have usable acoustic hearing, at least for low-frequency sounds, perception of music is likely to be much better with combined acoustic and electric stimulation than is typical for deaf people who rely solely on the hearing provided by their prostheses. PMID:15497033

  13. Music perception with cochlear implants: a review.

    PubMed

    McDermott, Hugh J

    2004-01-01

    The acceptance of cochlear implantation as an effective and safe treatment for deafness has increased steadily over the past quarter century. The earliest devices were the first implanted prostheses found to be successful in compensating partially for lost sensory function by direct electrical stimulation of nerves. Initially, the main intention was to provide limited auditory sensations to people with profound or total sensorineural hearing impairment in both ears. Although the first cochlear implants aimed to provide patients with little more than awareness of environmental sounds and some cues to assist visual speech-reading, the technology has advanced rapidly. Currently, most people with modern cochlear implant systems can understand speech using the device alone, at least in favorable listening conditions. In recent years, an increasing research effort has been directed towards implant users' perception of nonspeech sounds, especially music. This paper reviews that research, discusses the published experimental results in terms of both psychophysical observations and device function, and concludes with some practical suggestions about how perception of music might be enhanced for implant recipients in the future. The most significant findings of past research are: (1) On average, implant users perceive rhythm about as well as listeners with normal hearing; (2) Even with technically sophisticated multiple-channel sound processors, recognition of melodies, especially without rhythmic or verbal cues, is poor, with performance at little better than chance levels for many implant users; (3) Perception of timbre, which is usually evaluated by experimental procedures that require subjects to identify musical instrument sounds, is generally unsatisfactory; (4) Implant users tend to rate the quality of musical sounds as less pleasant than listeners with normal hearing; (5) Auditory training programs that have been devised specifically to provide implant users with structured musical listening experience may improve the subjective acceptability of music that is heard through a prosthesis; (6) Pitch perception might be improved by designing innovative sound processors that use both temporal and spatial patterns of electric stimulation more effectively and precisely to overcome the inherent limitations of signal coding in existing implant systems; (7) For the growing population of implant recipients who have usable acoustic hearing, at least for low-frequency sounds, perception of music is likely to be much better with combined acoustic and electric stimulation than is typical for deaf people who rely solely on the hearing provided by their prostheses.

  14. [Audiophonological evaluation of 16 children fitted with cochlear implants for sensorineural hearing loss induced by bacterial meningitis].

    PubMed

    Teissier, N; Doehring, I; Noel-Petroff, N; Elmaleh-Bergès, M; Viala, P; François, M; Faye, A; Van Den Abbeele, T; Lorrot, M

    2013-06-01

    Bacterial meningitis (BM) is the primary etiology of acquired sensorineural hearing loss (SNHL) in children and may compromise language development. Since the 1990 s, cochlear implants (CIs) have become part of the management of children with profound SNHL with encouraging results. The aim of this study was to analyze the audiophonological performance of children before and after cochlear implantation for SNHL following bacterial meningitis. Retrospective study of all children fitted with CIs for bilateral severe to profound SNHL after bacterial meningitis in the Robert-Debré pediatric ENT department between August 1990 and March 2009. Audiophonological performance was assessed using the APCEI profile. Of the 283 children receiving implants during that period, 16 children (6%; 6 boys, 10 girls) underwent CI implantation after bacterial meningitis (Streptococcus pneumoniae in 8 cases, Neisseria meningitidis in 2 cases, and Haemophilus influenzae in 4 cases). The mean time from meningitis to SNHL was 8.3 months (median, 1.5 months; range, 1 day to 13 years). The mean time from meningitis to cochlear implantation was 2 years and 3 months (median, 7 months; range, 1 month to 13 years 3 months). Twelve children (75%) presented partial cochlear and/or vestibular ossification on presurgical CT scan. Three children received bilateral implants. Thirteen children (81%) developed early SNHL in the first 3 months, whereas 3 children developed SNHL more than 10 months after meningitis. As for the benefits of cochlear implantation, 11 children presented near to normal intelligibility and optimal use of their cochlear implant; 5 children presented partial benefits due to neurological sequelae (1), a long delay before implantation (1), technical problems (2), or a social problem in relation to low socioeconomic status (1). After bacterial meningitis, audiological evaluation must be made carefully during the first 3 months to detect early SNHL, but SNHL may also develop several years later. In case of profound SNHL and a modified signal of the labyrinth on the MRI, cochlear implantation must be performed without delay before cochlear and/or vestibular ossification. Cochlear implantation is an effective technique with good long-term audiologic results. The coexistence of neurological lesions may compromise the results, but it should not contraindicate a cochlear implantation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  15. Revascularization of diaphyseal bone segments by vascular bundle implantation.

    PubMed

    Nagi, O N

    2005-11-01

    Vascularized bone transfer is an effective, established treatment for avascular necrosis and atrophic or infected nonunions. However, limited donor sites and technical difficulty limit its application. Vascular bundle transplantation may provide an alternative. However, even if vascular ingrowth is presumed to occur in such situations, its extent in aiding revascularization for ultimate graft incorporation is not well understood. A rabbit tibia model was used to study and compare vascularized, segmental, diaphyseal, nonvascularized conventional, and vascular bundle-implanted grafts with a combination of angiographic, radiographic, histopathologic, and bone scanning techniques. Complete graft incorporation in conventional grafts was observed at 6 months, whereas it was 8 to 12 weeks with either of the vascularized grafts. The pattern of radionuclide uptake and the duration of graft incorporation between vascular segmental bone grafts (with intact endosteal blood supply) and vascular bundle-implanted segmental grafts were similar. A vascular bundle implanted in the recipient bone was found to anastomose extensively with the intraosseous circulation at 6 weeks. Effective revascularization of bone could be seen when a simple vascular bundle was introduced into a segment of bone deprived of its normal blood supply. This simple technique offers promise for improvement of bone graft survival in clinical circumstances.

  16. Retrievable Günther Tulip Vena Cava Filter in the prevention of pulmonary embolism in patients with acute deep venous thrombosis in perinatal period.

    PubMed

    Köcher, Martin; Krcova, Vera; Cerna, Marie; Prochazka, Martin

    2009-04-01

    To evaluate the feasibility and efficacy of the retrievable Günther Tulip Vena Cava Filter in the prevention of pulmonary embolism in patients with acute deep vein thrombosis in the perinatal period and to discuss the technical demands associated with the filter's implantation and retrieval. Between 1996 until 2007, eight women (mean age 27.4 years, range 20-42 years) with acute deep iliofemoral venous thrombosis in the perinatal period of pregnancy and increased risk of pulmonary embolism during delivery were indicated for retrievable Günther Tulip Vena Cava Filter implantation. All filters were inserted and removed under local anesthesia from the jugular approach. The Günther Tulip Vena Cava Filter was implanted suprarenally in all patients on the day of caesarean delivery. In follow-up cavograms performed just before planned filter removal, no embolus was seen in the filter in any patient. In all patients the filter was retrieved without complications on the 12th day after implantation. Retrievable Günther Tulip Vena Cava Filters can be inserted and removed in patients during the perinatal period without major complications.

  17. Repair of olecranon fractures using fiberWire without metallic implants: report of two cases.

    PubMed

    Nimura, Akimoto; Nakagawa, Teruhiko; Wakabayashi, Yoshiaki; Sekiya, Ichiro; Okawa, Atsushi; Muneta, Takeshi

    2010-10-12

    Olecranon fractures are a common injury in fractures. The tension band technique for olecranon fractures yields good clinical outcomes; however, it is associated with significant complications. In many patients, implants irritate overlying soft tissues and cause pain. This is mostly due to protrusion of the proximal ends of the K-wires or by the twisted knots of the metal wire tension band. Below we described 2 cases of olecranon fractures treated with a unique technique using FiberWire without any metallic implants. Technically, the fragment was reduced, and two K-wires were inserted from the dorsal cortex of the distal segment to the tip of the olecranon. K-wire was exchanged for a suture retriever, and 2 strands of FiberWire were retrieved twice. Each of the two FiberWires was manually tensioned and knotted on the posterior surface of the olecranon. Bony unions could be achieved, and patients had no complaint of pain and skin irritation. There was only a small loss of flexion and extension in comparison with that of the contralateral side, and the patient did not feel inconvenienced in his daily life. Using the method described, difficulty due to K-wire or other metallic implants was avoided.

  18. Miniaturized neural interfaces and implants

    NASA Astrophysics Data System (ADS)

    Stieglitz, Thomas; Boretius, Tim; Ordonez, Juan; Hassler, Christina; Henle, Christian; Meier, Wolfgang; Plachta, Dennis T. T.; Schuettler, Martin

    2012-03-01

    Neural prostheses are technical systems that interface nerves to treat the symptoms of neurological diseases and to restore sensory of motor functions of the body. Success stories have been written with the cochlear implant to restore hearing, with spinal cord stimulators to treat chronic pain as well as urge incontinence, and with deep brain stimulators in patients suffering from Parkinson's disease. Highly complex neural implants for novel medical applications can be miniaturized either by means of precision mechanics technologies using known and established materials for electrodes, cables, and hermetic packages or by applying microsystems technologies. Examples for both approaches will be introduced and discussed. Electrode arrays for recording of electrocorticograms during presurgical epilepsy diagnosis have been manufactured using approved materials and a marking laser to achieve an integration density that is adequate in the context of brain machine interfaces, e.g. on the motor cortex. Microtechnologies have to be used for further miniaturization to develop polymer-based flexible and light weighted electrode arrays to interface the peripheral and central nervous system. Polyimide as substrate and insulation material will be discussed as well as several application examples for nerve interfaces like cuffs, filament like electrodes and large arrays for subdural implantation.

  19. Concrescence of permanent maxillary second and third molars: case report of non-surgical root canal treatment.

    PubMed

    Foran, Denise; Komabayashi, Takashi; Lin, Louis M

    2012-03-01

    Concrescence is a rare developmental anomaly with an overall incidence of 0.8% in the permanent dentition. While many case reports describe the treatment of concrescence with extraction, there are few reports of non-surgical root canal treatment (NSRCT), due to the atypical root form, canal morphology, and technical difficulties involved in concrescence. This unique case report describes a technical modification of NSRCT that can retain joined posterior maxillary teeth to maintain natural posterior occlusion without surgical intervention or dental implants, thereby avoiding the risk of damage to a large portion of the alveolar bone near the maxillary sinus.

  20. Energygrams: Brief descriptions of energy technology

    NASA Astrophysics Data System (ADS)

    Simpson, W. F., Jr.

    This compilation of technical notes (called Energygrams) is published by the Technical Information Center. Energygrams are usually one-page illustrated bulletins describing DOE technology or data and telling how to obtain the technical reports or other material on which they are based. Frequently a personal contact is given who can provide program information in addition to the data found in the reports. The compilation is organized by subject categories, and, within each category, Energygrams are presented alphabetically by Energygram title.

  1. Descriptive analysis of context evaluation instrument for technical oral presentation skills evaluation: A case study in English technical communication course

    NASA Astrophysics Data System (ADS)

    Mohamed, Abdullah-Adnan; Asmawi, Adelina; Hamid, Mohd Rashid Ab; Mustafa, Zainol bin

    2015-02-01

    This paper reports a pilot study of Context Evaluation using a self-developed questionnaire distributed among engineering undergraduates at a university under study. The study aims to validate the self-developed questionnaires used in the Context evaluation, a component in the CIPP Model. The Context evaluation assesses background information for needs, assets, problems and opportunities relevant to beneficiaries of the study in a defined environment. Through the questionnaire, background information for the assessment of needs, assets and problems related to the engineering undergraduates' perceptions on the teaching and learning of technical oral presentation skills was collected and analysed. The questionnaire was developed using 5-points Likert scale to measure the constructs under study. They were distributed to 100 respondents with 79 returned. The respondents consisted of engineering undergraduates studied at various faculties at one technical university in Malaysia. The descriptive analysis of data for each item which makes up the construct for Context evaluation is found to be high. This implied that engineering undergraduates showed high interest in teaching and learning of technical oral presentation skills, thus their needs are met. Also, they agreed that assets and facilities are conducive to their learning. In conclusion, the context evaluation involving needs and assets factors are both considerably important; their needs are met and the assets and facilities do support their technical oral presentation skills learning experience.

  2. MRI-based, wireless determination of the transfer function of a linear implant: Introduction of the transfer matrix.

    PubMed

    Tokaya, Janot P; Raaijmakers, Alexander J E; Luijten, Peter R; van den Berg, Cornelis A T

    2018-04-24

    We introduce the transfer matrix (TM) that makes MR-based wireless determination of transfer functions (TFs) possible. TFs are implant specific measures for RF-safety assessment of linear implants. The TF relates an incident tangential electric field on an implant to a scattered electric field at its tip that generally governs local heating. The TM extends this concept and relates an incident tangential electric field to a current distribution in the implant therewith characterizing the RF response along the entire implant. The TM is exploited to measure TFs with MRI without hardware alterations. A model of rightward and leftward propagating attenuated waves undergoing multiple reflections is used to derive an analytical expression for the TM. This allows parameterization of the TM of generic implants, e.g., (partially) insulated single wires, in a homogeneous medium in a few unknowns that simultaneously describe the TF. These unknowns can be determined with MRI making it possible to measure the TM and, therefore, also the TF. The TM is able to predict an induced current due to an incident electric field and can be accurately parameterized with a limited number of unknowns. Using this description the TF is determined accurately (with a Pearson correlation coefficient R ≥ 0.9 between measurements and simulations) from MRI acquisitions. The TM enables measuring of TFs with MRI of the tested generic implant models. The MR-based method does not need hardware alterations and is wireless hence making TF determination in more realistic scenarios conceivable. © 2018 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

  3. Real-world geographic variations in the use of cardiac implantable electronic devices - The PANORAMA 2 observational cohort study.

    PubMed

    Bastian, Dirk; Ebrahim, Iftikhar O; Chen, Ju-Yi; Chen, Mien-Cheng; Huang, Dejia; Huang, Jin-Long; Kuznetsov, Vadim A; Maus, Bärbel; Naik, Ajay M; Verhees, Koen J P; Fagih, Ahmed R Al

    2018-06-13

    Currently, several geographies around the world remain underrepresented in medical device trials. The PANORAMA 2 study was designed to assess contemporary region-specific differences in clinical practice patterns of patients with cardiac implantable electronic devices (CIEDs). In this prospective, multicenter, observational, multi-national study, baseline and implant data of 4,706 patients receiving Medtronic CIEDs (either de novo device implants, replacements, or upgrades) were analyzed, consisting of: 54% implantable pulse generators (IPGs), 20.3% implantable cardiac defibrillators (ICDs), 15% cardiac resynchronization therapy defibrillators (CRT-Ds), 5.1% cardiac resynchronization therapy pacemakers (CRT-Ps), from 117 hospitals in 23 countries across 4 geographical regions between 2012 and 2016. For all device types, in all regions, there were less females than males enrolled, and women were less likely to have ischemic cardiomyopathy. Implant procedure duration differed significantly across the geographies for all device types. Subjects from emerging countries, women and older patients were less likely to receive a magnetic resonance imaging (MRI)-compatible device. Defibrillation testing differed significantly between the regions. European patients had the highest rates of atrial fibrillation (AF), and the lowest number of implanted single-chamber IPGs. Evaluation of stroke history suggested that the general embolic risk is more strongly associated with stroke than AF. We provide comprehensive descriptive data on patients receiving Medtronic CIEDs from several geographies, some of which are understudied in randomized controlled trials (RCTs). We found significant variations in patient characteristics. Several medical decisions appear to be affected by socioeconomic factors. Long-term follow-up data will help evaluate if these variations require adjustments to outcome expectations. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  4. Turkish nurses' level of knowledge regarding implantable port catheter care.

    PubMed

    Özden, Dilek; Çalişkan, Nurcan

    2012-06-01

    The aim of this study was to determine the knowledge levels of Turkish nurses regarding implantable port catheter care. A descriptive method was used inside a university hospital that was located in a Turkish metropolis. The data were collected via a questionnaire that was given to a total of 45 nurses who were employed in the internal medicine clinics where the oncology patients were treated. In this study, 42.2% of the nurses received in-service training about the implantable port catheter. It was determined that the mean knowledge point was 15.13 ± 4.78. The difference between the knowledge points of the nurses regarding implantable port catheter care, based on whether or not the nurses had received in-service training, was statistically significant. Moreover, it was determined that the majority of the nurses did not know where the implantable port catheter is placed, its period of use following implantation, the amount of normal saline to be used for washing the catheter, the special port (Huber) needle, the number of the needle, and the exchange time of these needles. In this study, there existed significant differences between the scores of the nurses who received in-service training about the implantable port catheter and the scores of those who did not receive in-service training. The majority of the nurses who participated in the study were willing to receive in-service training regarding this subject. Thus, the organization of in-service training programs and the implementation of care, according to the developed standards and guidelines, are considered as significant for reducing the occurrence of the complications that are related to the use of the implantable port catheter. © 2011 The Authors. Japan Journal of Nursing Science © 2011 Japan Academy of Nursing Science.

  5. Anaplastic large cell lymphoma of the breast arising around mammary implant capsule: an Italian report.

    PubMed

    Farace, Francesco; Bulla, Antonio; Marongiu, Francesco; Campus, Gian Vittorio; Tanda, Francesco; Lissia, Amelia; Cossu, Antonio; Fozza, Claudio; Rubino, Corrado

    2013-06-01

    Anaplastic large cell lymphoma (ALCL) of the breast is a very rare nonepithelial neoplasm. In the literature, this tumor has sometimes been described in proximity of breast implants (60 implant-related ALCL reported). In 2010, a patient who had undergone a right mastectomy and tissue expander/implant reconstruction for a "ductal" carcinoma 10 years before was referred to our unit for evaluation. On examination, an enlarged reconstructed right breast was found. The reconstructed breast did not show tenderness or signs of infection, ulceration, or breakdown. Mammograms and ultrasound scan did not suggest the presence of recurrent cancer, infection, deflation of the implant, or severe capsule contracture. The patient underwent mammary implant replacement. About 3 weeks after surgery, the patient came back to our unit for a new mild enlargement of the operated breast and the implant was removed. Three months later, the patient returned with a skin lesion in the right parasternal region. A radical excisional biopsy was performed under local anesthesia and the diagnosis of ALK-1-negative ALCL was finally made. The clinical and histological diagnosis of this disease is difficult as it can often be mistaken for a simple seroma (breast enlargement), an infection, or an unspecific reaction to silicone (redness and/or tension of the skin, itching, and fever). We strongly suggest considering ALCL in any patient with a spontaneous breast seroma lasting more than 6 months after mammary prosthesis implantation. The suspicion of ALCL must be suggested to the pathologist immediately. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  6. Peri-implant soft tissue colour around titanium and zirconia abutments: a prospective randomized controlled clinical study.

    PubMed

    Cosgarea, Raluca; Gasparik, Cristina; Dudea, Diana; Culic, Bogdan; Dannewitz, Bettina; Sculean, Anton

    2015-05-01

    To objectively determine the difference in colour between the peri-implant soft tissue at titanium and zirconia abutments. Eleven patients, each with two contralaterally inserted osteointegrated dental implants, were included in this study. The implants were restored either with titanium abutments and porcelain-fused-to-metal crowns, or with zirconia abutments and ceramic crowns. Prior and after crown cementation, multi-spectral images of the peri-implant soft tissues and the gingiva of the neighbouring teeth were taken with a colorimeter. The colour parameters L*, a*, b*, c* and the colour differences ΔE were calculated. Descriptive statistics, including non-parametric tests and correlation coefficients, were used for statistical analyses of the data. Compared to the gingiva of the neighbouring teeth, the peri-implant soft tissue around titanium and zirconia (test group), showed distinguishable ΔE both before and after crown cementation. Colour differences around titanium were statistically significant different (P = 0.01) only at 1 mm prior to crown cementation compared to zirconia. Compared to the gingiva of the neighbouring teeth, statistically significant (P < 0.01) differences were found for all colour parameter, either before or after crown cementation for both abutments; more significant differences were registered for titanium abutments. Tissue thickness correlated positively with c*-values for titanium at 1 mm and 2 mm from the gingival margin. Within their limits, the present data indicate that: (i) The peri-implant soft tissue around titanium and zirconia showed colour differences when compared to the soft tissue around natural teeth, and (ii) the peri-implant soft tissue around zirconia demonstrated a better colour match to the soft tissue at natural teeth than titanium. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Graduate Periodontics Programs' Integration of Implant Provisionalization in Core Curricula: Implementation of CODA Standard 4-10.2.d.

    PubMed

    Barwacz, Christopher A; Pantzlaff, Ed; Allareddy, Veerasathpurush; Avila-Ortiz, Gustavo

    2017-06-01

    The aim of this descriptive study was to provide an overview of the status of implementation of Commission on Dental Accreditation (CODA) Standard 4-10.2.d (Provisionalization of Dental Implants) by U.S. graduate periodontics programs since its introduction in 2013. Surveys were sent in May 2015 to 56 accredited postdoctoral periodontics program directors to ascertain program director characteristics; status of planning, implementation, and curriculum resulting from adoption of Standard 4-10.2.d; preferred clinical protocols for implant provisionalization; interdisciplinary educational collaborators; and competency assessment mechanisms. The survey response rate was 52% (N=29); the majority were male, aged 55 or older, and had held their position for less than ten years. Among the responding programs, 93% had formal educational curricula established in implant provisionalization. Graduate periodontics (96%) and prosthodontics (63%) faculty members were predominantly involved with curriculum planning. Of these programs, 96% used immediate implant provisionalization, with direct (chairside) provisionalization protocols (86%) being preferred over indirect protocols (14%) and polyethylethylketone provisional abutments (75%) being preferred to titanium (25%) provisional abutments. Straight and concave transmucosal emergence profile designs (46% each) were preferred in teaching, with only 8% of programs favoring convex transmucosal profiles. A majority of responding programs (67%) lacked protocols for communicating to the restorative referral a mechanism to duplicate the mature peri-implant mucosal architecture. Regional location did not play a significant role in any educational component related to implant provisionalization for these graduate periodontal programs. Overall, this study found that a clear majority of graduate periodontics programs had established formal curricula related to implant provisionalization, with substantial clinical and philosophical consensus within the specialty.

  8. Modelling dental implant extraction by pullout and torque procedures.

    PubMed

    Rittel, D; Dorogoy, A; Shemtov-Yona, K

    2017-07-01

    Dental implants extraction, achieved either by applying torque or pullout force, is used to estimate the bone-implant interfacial strength. A detailed description of the mechanical and physical aspects of the extraction process in the literature is still missing. This paper presents 3D nonlinear dynamic finite element simulations of a commercial implant extraction process from the mandible bone. Emphasis is put on the typical load-displacement and torque-angle relationships for various types of cortical and trabecular bone strengths. The simulations also study of the influence of the osseointegration level on those relationships. This is done by simulating implant extraction right after insertion when interfacial frictional contact exists between the implant and bone, and long after insertion, assuming that the implant is fully bonded to the bone. The model does not include a separate representation and model of the interfacial layer for which available data is limited. The obtained relationships show that the higher the strength of the trabecular bone the higher the peak extraction force, while for application of torque, it is the cortical bone which might dictate the peak torque value. Information on the relative strength contrast of the cortical and trabecular components, as well as the progressive nature of the damage evolution, can be revealed from the obtained relations. It is shown that full osseointegration might multiply the peak and average load values by a factor 3-12 although the calculated work of extraction varies only by a factor of 1.5. From a quantitative point of view, it is suggested that, as an alternative to reporting peak load or torque values, an average value derived from the extraction work be used to better characterize the bone-implant interfacial strength. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Iris-claw versus posterior chamber fixation intraocular lens implantation in pediatric traumatic cataract☆

    PubMed Central

    Kavitha, V; Balasubramanian, Preethi; Heralgi, Mallikarjun M.

    2016-01-01

    Aim: This study aims to compare visual outcomes and complications of iris-fixated (claw) intraocular lens (IFIOL) implantation with those of posterior chamber intraocular lens (PCIOL) implantation in children with traumatic cataract. Settings and design: Retrospective observational clinical audit. Materials and methods: A total of 50 pediatric traumatic cataract cases that underwent lens removal and IOL implantation (IFIOL or PCIOL) with or without corneal or corneoscleral tear repair between January 2009 and December 2013 were analyzed. After meeting the eligibility criteria, their pre- and postoperative visual outcomes and complication rates were recorded. Data were analyzed descriptively. Results: Out of 50 children, IFIOL and PCIOL implantations were performed in one eye of each of 25 children. Their mean age was 11 ± 4 years (range 4–18 years). Primary (cataract removal with lens implantation) and secondary (corneal tear repair followed by cataract removal with lens implantation) procedures were performed in 19 (76%) and six (24%) children in the IFIOL group and in 21 (84%) and four (16%) children in the PCIOL group, respectively. There was an improvement in best corrected visual acuity postimplantation in both the IFIOL and the PCIOL group, and no significant difference in the logarithm of the minimum angle of resolution of best corrected visual acuity was observed between the two groups over 36 months. Only three eyes in the IFIOL group developed complications: one eye developed secondary glaucoma, one disenclavation of IOL haptic, and one cystoid macular edema. Conclusion: Both IFIOL and PCIOL implantations have good visual outcomes and minimal postoperative complications; therefore, IFIOL can be used as an alternative to PCIOL in children with traumatic cataract with inadequate capsular support. PMID:29018714

  10. The Use of Light/Chemically Hardened Polymethylmethacrylate, Polyhydroxylethylmethacrylate, and Calcium Hydroxide Graft Material in Combination With Polyanhydride Around Implants and Extraction Sockets in Minipigs: Part II: Histologic and Micro-CT Evaluations

    PubMed Central

    Hasturk, Hatice; Kantarci, Alpdogan; Ghattas, Mazen; Dangaria, Smit J.; Abdallah, Rima; Morgan, Elise F.; Diekwisch, Thomas G.H.; Ashman, Arthur; Van Dyke, Thomas

    2015-01-01

    Background This report is the second part of the previously published study on the impact of light/chemical hardening technology and a newly formulated composite graft material for crestal augmentation during immediate implant placement. Methods A total of 48 implants were placed into the sockets of the mesial roots of freshly extracted mandibular premolar teeth in three minipigs. Crestal areas and intrabony spaces were randomly augmented with light-hardened graft materials including a composite graft consisting of polymethylmethacrylate, polyhydroxylethylmethacrylate, and calcium hydroxide (PPCH) plus polyanhydride (PA); PPCH graft; and PA graft, or left untreated. Distal sockets not receiving implants and the sockets of first molars (n = 60) were randomly treated with one of the graft materials or left empty. In addition, two molar sockets were treated with the original PPCH graft material. Quantitative microcomputed tomography (micro-CT) was used to assess alveolar bone structure and tissue compositions. Histologic evaluations included descriptive histology to assess the peri-implant wound healing, as well as histomorphometric measurements to determine bone-to-implant contact (BIC). Results Both trabecular and cortical bone measurements by micro-CT did not reveal any significant differences among the groups. Sites augmented with PPCH+PA resulted in significantly greater BIC surface than PPCH alone and no-graft-treated implants (P <0.05) histologically. Stained ground sections showed complete bone formation between bone and implant surface in the PPCH+PA group, whereas sites without augmentation showed large gaps between bone and implant surfaces, indicating a slower bone apposition and less BIC surface compared to all other groups. Similar to implant sections, all materials showed positive outcome on trabecular and cortical bone formation in extraction sockets with an intact crestal cortical bone. Conclusion Histologic evaluations supported the previous findings on implant stability and function and confirmed that PPCH+PA provides a greater BIC with a well-organized implant–bone interface and is useful in crestal augmentation during immediate implant placement. PMID:24502615

  11. Parents' views on the quality of life of their children 2-3 years after cochlear implantation.

    PubMed

    Huttunen, K; Rimmanen, S; Vikman, S; Virokannas, N; Sorri, M; Archbold, S; Lutman, M E

    2009-12-01

    Cochlear implants for children are known to have impact on the lives of recipients and their families in a variety of ways. To obtain a clearer picture of these benefits, we explored the quality of life of 36 Finnish children and their families 2-3 years after unilateral cochlear implantation. The studied children were, on average 5 years old, and had received their implant at the median age of 2 years:5 months (range 1:6 to 12:3). Most (67%) of the children used speech, eight (22%) used speech and signs, and four (11%) used sign language as their main communication mode. A third of the children had concomitant problems in addition to their profound hearing impairment. A validated closed-set questionnaire "Children with cochlear implants: parental perspectives" (available, e.g., at http://www.earfoundation.org.uk/research/questionnaires.html) was used to find out parents' views and experiences on implantation and explore life after it. Parents were most satisfied with improved/expanded social relations, improved communication (the development of spoken language), general functioning with the help of hearing and improved self-reliance of the child. Benefit of cochlear implantation was also detected with the Categories of Auditory Performance (CAP), which was concordant with views of the parents on the progress of their child in the areas of communication and education. When deciding on implantation, the parents particularly expected auditory information to enhance their child's safety in traffic, joining socially the hearing world, and better employment prospects as adults. Concerning the process of implantation, parents especially valued the know-how and fluent services of the implant centre, positive attitude within the family and information received from other families during the time they were considering the implant decision. Parents also found it important that they have the possibility to influence the communication mode that is used in their child's educational setting. Parents report that cochlear implants affect their children in a wide variety of ways that cannot be summarized by a single scale. A broader descriptive framework is required to capture their experiences adequately.

  12. Oak Ridge TNS Program: system description manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reid, R.L.; Becraft, W.R.; Brown, T.G.

    1979-05-01

    This document provides a systems description of the Reference Design for The Next Step (TNS) evolved at Oak Ridge National Laboratory (ORNL) during FY 1978. The description is presented on the basis of 24 individual device and facility systems. Additional information on these systems, the Reference Design, and the FY 1978 Oak Ridge TNS activities can be found in the associated technical memoranda, ORNL/TM-6720 and ORNL/TM-6722--ORNL/TM-6733.

  13. Retirement Forecasting. Technical Descriptions of Cost, Decision and Income Models. Volume 2. Report to the Chairman, Subcommittee on Social Security and Income Maintenance Programs, Committee on Finance, United States Senate.

    ERIC Educational Resources Information Center

    General Accounting Office, Washington, DC.

    This supplementary report identifies and provides individual descriptions and reviews of 71 retirement forecasting models. Composed of appendices, it is intended as a source of more detailed information than that included in the main volume of the report. Appendix I is an introduction. Appendix II contains individual descriptions of 32 models of…

  14. Mandibular molar uprighting using mini-implants: different approaches for different clinical cases--two case reports.

    PubMed

    Derton, Nicola; Perini, Alessandro; Mutinelli, Sabrina; Gracco, Antonio

    2012-01-01

    To detail two different clinical protocols and case studies using mini-implant anchorage developed to respond to certain clinical conditions. Two clinical protocols are described to upright mesially tilted mandibular molars. In the first protocol, a single mini-implant is inserted distally to the molar to be uprighted, and an elastic traction chain is applied to the tooth. In the second clinical approach, two mini-implants are inserted mesially. A screw-suspended TMA sectional archwire is applied (Derton-Perini technique). Two cases, descriptive of the two different treatment protocols, are described. In the first case, the mandibular right second premolar was missing and the adjacent first molar needed to be uprighted. A single screw was inserted distally to the first molar, and an elastic chain was applied. In the second case, the mandibular left second molar was missing and the third molar needed to be uprighted. Two mini-implants were inserted mesially and a fully screw-supported sectional archwire was used to upright and bodily mesialize the third molar. Both uprighting approaches uprighted the molar axis without loss of anchorage. The two approaches to mandibular molar uprighting, developed as rational responses to different clinical cases, were both found to be effective.

  15. FAST FLUX TEST FACILITY CONCEPTUAL FACILTY DESIGN DESCRIPTION FOR THE INERT GAS CELL EXAMINATION FACILITY NO. 71

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1968-12-12

    The purpose of this Conceptual Facility Design Description (CFDD) is to provide a technical description of the Inert Gas Cell Examination Facility such that agreement with RDT on a Conceptual Design can be reached . The CFDD also serves to establish a common understanding of the facility concept among all responsible FFTF Project parties including the Architect Engineer and Reactor Designer. Included are functions and design requirements, a physical description of the facility, safety considerations, principles of operation, and maintenance principles.

  16. Surface modification of biomaterials using plasma immersion ion implantation and deposition

    PubMed Central

    Lu, Tao; Qiao, Yuqin; Liu, Xuanyong

    2012-01-01

    Although remarkable progress has been made on biomaterial research, the ideal biomaterial that satisfies all the technical requirements and biological functions is not available up to now. Surface modification seems to be a more economic and efficient way to adjust existing conventional biomaterials to meet the current and ever-evolving clinical needs. From an industrial perspective, plasma immersion ion implantation and deposition (PIII&D) is an attractive method for biomaterials owing to its capability of treating objects with irregular shapes, as well as the control of coating composition. It is well acknowledged that the physico-chemical characteristics of biomaterials are the decisive factors greatly affecting the biological responses of biomaterials including bioactivity, haemocompatibility and antibacterial activity. Here, we mainly review the recent advances in surface modification of biomaterials via PIII&D technology, especially titanium alloys and polymers used for orthopaedic, dental and cardiovascular implants. Moreover, the variations of biological performances depending on the physico-chemical properties of modified biomaterials will be discussed. PMID:23741609

  17. The chemistry of cyborgs--interfacing technical devices with organisms.

    PubMed

    Giselbrecht, Stefan; Rapp, Bastian E; Niemeyer, Christof M

    2013-12-23

    The term "cyborg" refers to a cybernetic organism, which characterizes the chimera of a living organism and a machine. Owing to the widespread application of intracorporeal medical devices, cyborgs are no longer exclusively a subject of science fiction novels, but technically they already exist in our society. In this review, we briefly summarize the development of modern prosthetics and the evolution of brain-machine interfaces, and discuss the latest technical developments of implantable devices, in particular, biocompatible integrated electronics and microfluidics used for communication and control of living organisms. Recent examples of animal cyborgs and their relevance to fundamental and applied biomedical research and bioethics in this novel and exciting field at the crossroads of chemistry, biomedicine, and the engineering sciences are presented. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Development and evaluation of the Nurotron 26-electrode cochlear implant system.

    PubMed

    Zeng, Fan-Gang; Rebscher, Stephen J; Fu, Qian-Jie; Chen, Hongbin; Sun, Xiaoan; Yin, Li; Ping, Lichuan; Feng, Haihong; Yang, Shiming; Gong, Shusheng; Yang, Beibei; Kang, Hou-Yong; Gao, Na; Chi, Fanglu

    2015-04-01

    Although the cochlear implant has been widely acknowledged as the most successful neural prosthesis, only a fraction of hearing-impaired people who can potentially benefit from a cochlear implant have actually received one due to its limited awareness, accessibility, and affordability. To help overcome these limitations, a 26-electrode cochlear implant has been developed to receive China's Food and Drug Administration (CFDA) approval in 2011 and Conformité Européenne (CE) Marking in 2012. The present article describes design philosophy, system specification, and technical verification of the Nurotron device, which includes advanced digital signal processing and 4 current sources with multiple amplitude resolutions that not only are compatible with perceptual capability but also allow interleaved or simultaneous stimulation. The article also presents 3-year longitudinal evaluation data from 60 human subjects who have received the Nurotron device. The objective measures show that electrode impedance decreased within the first month of device use, but was stable until a slight increase at the end of two years. The subjective loudness measures show that electric stimulation threshold was stable while the maximal comfort level increased over the 3 years. Mandarin sentence recognition increased from the pre-surgical 0%-correct score to a plateau of about 80% correct with 6-month use of the device. Both indirect and direct comparisons indicate indistinguishable performance differences between the Nurotron system and other commercially available devices. The present 26-electrode cochlear implant has already helped to lower the price of cochlear implantation in China and will likely contribute to increased cochlear implant access and success in the rest of the world. This article is part of a Special Issue entitled . Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  19. Fully Passive Wireless Acquisition of Neuropotentials

    NASA Astrophysics Data System (ADS)

    Schwerdt, Helen N.

    The ability to monitor electrophysiological signals from the sentient brain is requisite to decipher its enormously complex workings and initiate remedial solutions for the vast amount of neurologically-based disorders. Despite immense advancements in creating a variety of instruments to record signals from the brain, the translation of such neurorecording instrumentation to real clinical domains places heavy demands on their safety and reliability, both of which are not entirely portrayed by presently existing implantable recording solutions. In an attempt to lower these barriers, alternative wireless radar backscattering techniques are proposed to render the technical burdens of the implant chip to entirely passive neurorecording processes that transpire in the absence of formal integrated power sources or powering schemes along with any active circuitry. These radar-like wireless backscattering mechanisms are used to conceive of fully passive neurorecording operations of an implantable microsystem. The fully passive device potentially manifests inherent advantages over current wireless implantable and wired recording systems: negligible heat dissipation to reduce risks of brain tissue damage and minimal circuitry for long term reliability as a chronic implant. Fully passive neurorecording operations are realized via intrinsic nonlinear mixing properties of the varactor diode. These mixing and recording operations are directly activated by wirelessly interrogating the fully passive device with a microwave carrier signal. This fundamental carrier signal, acquired by the implant antenna, mixes through the varactor diode along with the internal targeted neuropotential brain signals to produce higher frequency harmonics containing the targeted neuropotential signals. These harmonics are backscattered wirelessly to the external interrogator that retrieves and recovers the original neuropotential brain signal. The passive approach removes the need for internal power sources and may alleviate heat trauma and reliability issues that limit practical implementation of existing implantable neurorecorders.

  20. Analysis of load distribution in tooth-implant supported fixed partial dentures by the use of resilient abutment.

    PubMed

    Glisić, Mirko; Stamenković, Dragoslav; Grbović, Aleksandar; Todorović, Aleksandar; Marković, Aleksa; Trifković, Branka

    2016-01-01

    Differences between the tooth and implant response to load can lead to many biological and technical implications in the conditions of occlusal forces. The objective of this study was to analyze load distribution in tooth/implant-supported fixed partial dentures with the use of resilient TSA (Titan Shock Absorber, BoneCare GmbH, Augsburg, Germany) abutment and conventional non-resilient abutment using finite element method. This study presents two basic 3D models. For one model a standard non-resilient abutment is used, and on the implant of the second model a resilient TSA abutment is applied. The virtual model contains drawn contours of tooth, mucous membranes, implant, cortical bones and spongiosa, abutment and suprastructure. The experiment used 500 N of vertical force, applied in three different cases of axial load. Calculations of von Mises equivalent stresses of the tooth root and periodontium, implants and peri-implant tissue were made. For the model to which a non-resilient abutment is applied, maximum stress values in all three cases are observed in the cortical part of the bone (maximum stress value of 49.7 MPa). Measurements of stress and deformation in the bone tissue in the model with application of the resilientTSA abutment demonstrated similar distribution; however, these values are many times lower than in the model with non-resilient TSA abutment (maximum stress value of 28.9 MPa). Application of the resilient TSA abutment results in more equal distribution of stress and deformations in the bone tissue under vertical forces. These values are many times lower than in the model with the non-resilient abutment.

  1. Improving neuromodulation technique for refractory voiding dysfunctions: two-stage implant.

    PubMed

    Janknegt, R A; Weil, E H; Eerdmans, P H

    1997-03-01

    Neuromodulation is a new technique that uses electrical stimulation of the sacral nerves for patients with refractory urinary urge/frequency or urge-incontinence, and some forms of urinary retention. The limiting factor for receiving an implant is often a failure of the percutaneous nerve evaluation (PNE) test. Present publications mention only about a 50% success score for PNE of all patients, although the micturition diaries and urodynamic parameters are similar. We wanted to investigate whether PNE results improved by using a permanent electrode as a PNE test. This would show that improvement of the PNE technique is feasible. In 10 patients where the original PNE had failed to improve the micturition diary parameters more than 50%, a permanent electrode was implanted by operation. It was connected to an external stimulator. In those cases where the patients improved according to their micturition diary by more than 50% during a period of 4 days, the external stimulator was replaced by a permanent subcutaneous neurostimulator. Eight of the 10 patients had a good to very good result (60% to 90% improvement) during the testing period and received their implant 5 to 14 days after the first stage. The good results of the two-stage implant technique we used indicate that the development of better PNE electrodes may lead to an improvement of the testing technique and better selection between nonresponders and technical failures.

  2. SEM and fractography analysis of screw thread loosening in dental implants.

    PubMed

    Scarano, A; Quaranta, M; Traini, T; Piattelli, M; Piattelli, A

    2007-01-01

    Biological and technical failures of implants have already been reported. Mechanical factors are certainly of importance in implant failures, even if their exact nature has not yet been established. The abutment screw fracture or loosening represents a rare, but quite unpleasant failure. The aim of the present research is an analysis and structural examination of screw thread or abutment loosening compared with screw threads or abutment without loosening. The loosening of screw threads was compared to screw thread without loosening of three different implant systems; Branemark (Nobel Biocare, Gothenburg, Sweden), T.B.R. implant systems (Benax, Ancona, Italy) and Restore (Lifecore Biomedical, Chaska, Minnesota, USA). In this study broken screws were excluded. A total of 16 screw thread loosenings were observed (Group I) (4 Branemark, 4 T.B.R and 5 Restore), 10 screw threads without loosening were removed (Group II), and 6 screw threads as received by the manufacturer (unused) (Group III) were used as control (2 Branemark, 2 T.B.R and 2 Restore). The loosened abutment screws were retrieved and analyzed under SEM. Many alterations and deformations were present in concavities and convexities of screw threads in group I. No macroscopic alterations or deformations were observed in groups II and III. A statistical difference of the presence of microcracks were observed between screw threads with an abutment loosening and screw threads without an abutment loosening.

  3. Fin field effect transistor directionality impacts printing of implantation shapes

    NASA Astrophysics Data System (ADS)

    Wang, Xiren; Granik, Yuri

    2018-01-01

    In modern integrated circuit (IC) fabrication processes, the photoresist receives considerable illumination energy that is reflected by underlying topography during optical lithography of implantation layers. Bottom antireflective coating (BARC) is helpful to mitigate the reflection. Often, however, BARC is not used, because its removal is technically challenging, in addition to its relatively high economic cost. Furthermore, the advanced technology nodes, such as 14/10-nm nodes, have introduced fin field effect transistor (FinFET), which makes reflection from nonuniform silicon substrates exceptionally complicated. Therefore, modeling reflection from topography becomes obligatory to accurately predict printing of implantation shapes. Typically, FinFET is always fixed in one direction in realistic designs. However, the same implantation rectangle may be oriented in either horizontal or vertical direction. Then, there are two types of relations between the critical dimension (CD) and FinFET, namely a parallel-to and a perpendicular-to relation. We examine the fin directionality impact on CD. We found that this impact may be considerable in some cases. We use our in-house rigorous optical topography simulator to reveal underlining physical reasons. One of the major causes of the CD differences is that in the parallel orientation, the solid sidewalls of the fins conduct considerable light reflections unlike for the perpendicular orientation. This finding can aid the compact modeling in optical proximity correction of implantation masks.

  4. Surgery without papilla incision: tunneling flap procedures in plastic periodontal and implant surgery.

    PubMed

    Zuhr, Otto; Rebele, Stephan F; Cheung, Stefani L; Hürzeler, Markus B

    2018-06-01

    Diverse clinical advancements, together with some relevant technical innovations, have led to an increase in popularity of tunneling flap procedures in plastic periodontal and implant surgery in the recent past. This trend is further promoted by the fact that these techniques have lately been introduced to a considerably expanded range of indications. While originally described for the treatment of gingival recession-type defects, tunneling flap procedures may now be applied successfully in a variety of clinical situations in which augmentation of the soft tissues is indicated in the esthetic zone. Potential clinical scenarios include surgical thickening of thin buccal gingiva or peri-implant mucosa, alveolar ridge/socket preservation and implant second-stage surgery, as well as soft-tissue ridge augmentation or pontic site development. In this way, tunneling flap procedures developed from a technique, originally merely intended for surgical root coverage, into a capacious surgical conception in plastic periodontal and implant surgery. The purpose of this article is to provide a comprehensive overview on tunneling flap procedures, to introduce the successive development of the approach along with underlying ideas on surgical wound healing and to present contemporary clinical scenarios in step-by-step photograph-illustrated sequences, which aim to provide clinicians with guidance to help them integrate tunneling flap procedures into their daily clinical routine. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Surgical and Technical Modalities for Hearing Restoration in Ear Malformations.

    PubMed

    Dazert, Stefan; Thomas, Jan Peter; Volkenstein, Stefan

    2015-12-01

    Malformations of the external and middle ear often go along with an aesthetic and functional handicap. Independent of additional aesthetic procedures, a successful functional hearing restoration leads to a tremendous gain in quality of life for affected patients. The introduction of implantable hearing systems (bone conduction and middle ear devices) offers new therapeutic options in this field. We focus on functional rehabilitation of patients with malformations, either by surgical reconstruction or the use of different implantable hearing devices, depending on the disease itself and the severity of malformation as well as hearing impairment. Patients with an open ear canal and minor malformations are good candidates for surgical hearing restoration of middle ear structures with passive titanium or autologous implants. In cases with complete fibrous or bony atresia of the ear canal, the most promising functional outcome and gain in quality of life can be expected with an active middle ear implant or a bone conduction device combined with a surgical aesthetic rehabilitation in a single or multi-step procedure. Although the surgical procedure for bone conduction devices is straightforward and safe, more sophisticated operations for active middle ear implants (e.g., Vibrant Soundbridge, MED-EL, Innsbruck, Austria) provide an improved speech discrimination in noise and the ability of sound localization compared with bone conduction devices where the stimulation reaches both cochleae. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  6. High definition surface micromachining of LiNbO 3 by ion implantation

    NASA Astrophysics Data System (ADS)

    Chiarini, M.; Bentini, G. G.; Bianconi, M.; De Nicola, P.

    2010-10-01

    High Energy Ion Implantation (HEII) of both medium and light mass ions has been successfully applied for the surface micromachining of single crystal LiNbO 3 (LN) substrates. It has been demonstrated that the ion implantation process generates high differential etch rates in the LN implanted areas, when suitable implantation parameters, such as ion species, fluence and energy, are chosen. In particular, when traditional LN etching solutions are applied to suitably ion implanted regions, etch rates values up to three orders of magnitude higher than the typical etching rates of the virgin material, are registered. Further, the enhancement in the etching rate has been observed on x, y and z-cut single crystalline material, and, due to the physical nature of the implantation process, it is expected that it can be equivalently applied also to substrates with different crystallographic orientations. This technique, associated with standard photolithographic technologies, allows to generate in a fast and accurate way very high aspect ratio relief micrometric structures on LN single crystal surface. In this work a description of the developed technology is reported together with some examples of produced micromachined structures: in particular very precisely defined self sustaining suspended structures, such as beams and membranes, generated on LN substrates, are presented. The developed technology opens the way to actual three dimensional micromachining of LN single crystals substrates and, due to the peculiar properties characterising this material, (pyroelectric, electro-optic, acousto-optic, etc.), it allows the design and the production of complex integrated elements, characterised by micrometric features and suitable for the generation of advanced Micro Electro Optical Systems (MEOS).

  7. Trends in funding, internationalization, and types of study for original articles published in five implant-related journals between 2005 and 2009.

    PubMed

    Barão, Valentim Adelino Ricardo; Shyamsunder, Nodesh; Yuan, Judy Chia-Chun; Knoernschild, Kent L; Assunção, Wirley Gonçalves; Sukotjo, Cortino

    2012-01-01

    The aims of this study were to evaluate the trends in funding, geographic origin, and study types of original articles in the dental implant literature and to investigate the relationships among these factors. Articles published in Clinical Oral Implants Research, The International Journal of Oral and Maxillofacial Implants, Clinical Implant Dentistry and Related Research, Implant Dentistry, and Journal of Oral Implantology from 2005 to 2009 were reviewed. Nonoriginal articles were excluded. For each article included, extramural funding source, geographic origin, and study type were recorded. Descriptive and analytic analyses (α = .05), including a logistic regression analysis, and chi-square test were used where appropriate. Of a total of 2,085 articles published, 1,503 met the inclusion criteria. The most common source of funding was from industry (32.4%). The proportion of studies that reported funding increased significantly over time. Europe represented the highest percentage (55.8%) of published articles. Most of the articles reported on clinical studies (49.9%), followed by animal studies (25.9%). Articles from Asia and South America and animal and in vitro studies were significantly more likely to be funded. Almost half of the original dental implant articles were funded. The trend toward internationalization of authorship was evident. A strong association was observed between funding and geographic origin and between funding and study type. Most studies in North America and Europe were clinical studies and supported by industry, whereas a greater proportion of studies in Asia and South America were in vitro or animal studies funded through government resources.

  8. NETAC Networks. Providing Technical Assistance to Professionals Working with Students Who Are Deaf and Hard of Hearing in Postsecondary Settings

    ERIC Educational Resources Information Center

    Northeast Technical Assistance Center (NETAC), Rochester Institute of Technology, 2004

    2004-01-01

    Highlights of this issue include: (1) Accommodating College Students with Cochlear Implants (Catherine Clark); (2) The Director's Column (Dianne Brooks); (3) Upcoming Events by State; (4) Practice What you Preach! (Jane Jarrow); (5) NETAC Central Office/Site Coordinators tear-out page; and (6) "Starting Off on the Right Foot" Program…

  9. Subclavian Vein Versus Arm Vein for Totally Implantable Central Venous Port for Patients with Head and Neck Cancer: A Retrospective Comparative Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akahane, Akio, E-mail: a.akahane@gmail.com; Sone, Miyuki; Ehara, Shigeru

    2011-12-15

    Purpose: This study was designed to compare central venous ports (CVP) from two different routes of venous access-the subclavian vein and arm vein-in terms of safety for patients with head and neck cancer (HNC). Methods: Patients with HNC who underwent image-guided implantations of CVPs were retrospectively evaluated. All CVPs were implanted under local anesthesia. Primary outcome measurements were rates and types of adverse events (AEs). Secondary outcomes included technical success and rate and reason of CVP removal. Results: A total of 162 patients (subclavian port group, 47; arm port group, 115) were included in this study. Technical success was achievedmore » in all patients. The median follow-up period was 94 (range, 1-891) days. Two patients in the subclavian port group experienced periprocedural complications. Postprocedural AEs were observed in 8.5 and 22.6% of the subclavian port and arm port group patients, respectively (P = 0.044). Phlebitis and system occlusions were observed only in the arm port group. The rate of infection was not significantly different between the two groups. The CVP was removed in 34 and 39.1% of the subclavian port and arm port patients, respectively. Conclusions: Both subclavian and arm CVPs are feasible in patients with HNC. AEs were more frequent in the arm port group; thus, the arm port is not recommended as the first choice for patients with HNC. However, further experience is needed to improve the placement technique and the maintenance of CVPs and a prospective analysis is warranted.« less

  10. How, why, and when may atrial defibrillation find a specific role in implantable devices? A clinical viewpoint.

    PubMed

    Boriani, Giuseppe; Diemberger, Igor; Biffi, Mauro; Martignani, Cristian; Ziacchi, Matteo; Bertini, Matteo; Valzania, Cinzia; Bronzetti, Gabriele; Rapezzi, Claudio; Branzi, Angelo

    2007-03-01

    This viewpoint article discusses the potential for incorporation of atrial defibrillation capabilities in modern multi-chamber devices. In the late 1990s, the possibility of using shock-only therapy to treat selected patients with recurrent atrial fibrillation (AF) was explored in the context of the stand-alone atrial defibrillator. The failure of this strategy can be attributed to the technical limitations of the stand-alone device, low tolerance of atrial shocks, difficulties in patient selection, a lack of predictive knowledge about the evolution of AF, and, last but not least, commercial considerations. An open question is how atrial defibrillation capability may now assume a specific new role in devices implanted for sudden death prevention or cardiac resynchronization. For patients who already have indications for implantable devices, device-based atrial defibrillation appears attractive as a "backup" option for managing AF when preventive pharmacological/electrical measures fail. This and several other personalized hybrid therapeutic approaches await exploration, though assessment of their efficacy is methodologically challenging. Achievement of acceptance by patients is an essential premise for any updated atrial defibrillation strategy. Strategies that are being investigated to improve patient tolerance include waveform shaping, pharmacologic modulation of pain, and patient-activated defibrillation (patients might also perceive the problem of discomfort somewhat differently in the context of a backup therapy). The economic impact of implementing atrial defibrillation features in available devices is progressively decreasing, and financial feasibility need not be a major issue. Future studies should examine clinically relevant outcomes and not be limited (as occurred with stand-alone defibrillators) to technical or other soft endpoints.

  11. Visual Prostheses: The Enabling Technology to Give Sight to the Blind

    PubMed Central

    Maghami, Mohammad Hossein; Sodagar, Amir Masoud; Lashay, Alireza; Riazi-Esfahani, Hamid; Riazi-Esfahani, Mohammad

    2014-01-01

    Millions of patients are either slowly losing their vision or are already blind due to retinal degenerative diseases such as retinitis pigmentosa (RP) and age-related macular degeneration (AMD) or because of accidents or injuries. Employment of artificial means to treat extreme vision impairment has come closer to reality during the past few decades. Currently, many research groups work towards effective solutions to restore a rudimentary sense of vision to the blind. Aside from the efforts being put on replacing damaged parts of the retina by engineered living tissues or microfabricated photoreceptor arrays, implantable electronic microsystems, referred to as visual prostheses, are also sought as promising solutions to restore vision. From a functional point of view, visual prostheses receive image information from the outside world and deliver them to the natural visual system, enabling the subject to receive a meaningful perception of the image. This paper provides an overview of technical design aspects and clinical test results of visual prostheses, highlights past and recent progress in realizing chronic high-resolution visual implants as well as some technical challenges confronted when trying to enhance the functional quality of such devices. PMID:25709777

  12. Inputs to Vocational-Technical Education from Occupational Research.

    ERIC Educational Resources Information Center

    Christal, Raymond E.

    The Air Force has developed a data bank which classifies job descriptions into occupational clusters. A retrieval system, also recently developed computes and publishes a consolidated description of the work being performed by any group which can be defined in terms of the background information. Other retrieval programs are available which enable…

  13. 75 FR 26193 - Notice of Funds Availability: Inviting Applications for the Technical Assistance for Specialty...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-11

    .... The intended effect of this notice is to solicit applications from the private sector and from... description of relevant dates. FOR FURTHER INFORMATION CONTACT: Entities wishing to apply for funding.... Funding Opportunity Description Authority: The TASC program is authorized by section 3205 of Public Law...

  14. 15 CFR Supplement No. 1 to Part 748 - BIS-748P, BIS-748P-A; Item Appendix, and BIS-748P-B; End-User Appendix; Multipurpose Application...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... “Tech. Specs.” box with an (X) if you are submitting descriptive literature, brochures, technical... or B. Be specific—vague descriptions such as “research”, “manufacturing”, or “scientific uses” are...

  15. 15 CFR Supplement No. 1 to Part 748 - BIS-748P, BIS-748P-A; Item Appendix, and BIS-748P-B; End-User Appendix; Multipurpose Application...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... “Tech. Specs.” box with an (X) if you are submitting descriptive literature, brochures, technical... or B. Be specific—vague descriptions such as “research”, “manufacturing”, or “scientific uses” are...

  16. 15 CFR Supplement No. 1 to Part 748 - BIS-748P, BIS-748P-A; Item Appendix, and BIS-748P-B; End-User Appendix; Multipurpose Application...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... “Tech. Specs.” box with an (X) if you are submitting descriptive literature, brochures, technical... or B. Be specific—vague descriptions such as “research”, “manufacturing”, or “scientific uses” are...

  17. 15 CFR Supplement No. 1 to Part 748 - BIS-748P, BIS-748P-A; Item Appendix, and BIS-748P-B; End-User Appendix; Multipurpose Application...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... “Tech. Specs.” box with an (X) if you are submitting descriptive literature, brochures, technical... or B. Be specific—vague descriptions such as “research”, “manufacturing”, or “scientific uses” are...

  18. 78 FR 5176 - Information Collection Being Reviewed by the Federal Communications Commission Under Delegated...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-24

    .... Frequency of Response: Third party disclosure. Obligation to Respond: Required to obtain or retain benefits..., phone number of the applicant, description of why the STA is needed, description of the operation to be... base and mobile units, power, emission designator, and any other pertinent technical information not...

  19. Critical Competitors. Evaluation of the Bay Area Writing Project. Technical Report.

    ERIC Educational Resources Information Center

    Thomas, Susan; Watson, Patti

    Prepared as part of the evaluation of the Bay Area Writing Project (BAWP), this report compares BAWP to its "critical competitors" (other inservice teacher programs and programs for improving student writing). The BAWP model and ten other program descriptions are presented in identical descriptive formats. Three types of competitors are…

  20. Description of the KEEP Reading Curriculum, 1975-76. Technical Report No. 43.

    ERIC Educational Resources Information Center

    Au, Kathryn H.

    The Kamehameha Early Education Program (KEEP) is a research and development program designed to develop, demonstrate, and disseminate methods for improving the education of Hawaiian and part-Hawaiian children; this report contains a description of the reading curriculum used in the KEEP demonstration school during the 1975-76 school year. The…

  1. Lightning Protection Guidelines for Aerospace Vehicles

    NASA Technical Reports Server (NTRS)

    Goodloe, C. C.

    1999-01-01

    This technical memorandum provides lightning protection engineering guidelines and technical procedures used by the George C. Marshall Space Flight Center (MSFC) Electromagnetics and Aerospace Environments Branch for aerospace vehicles. The overviews illustrate the technical support available to project managers, chief engineers, and design engineers to ensure that aerospace vehicles managed by MSFC are adequately protected from direct and indirect effects of lightning. Generic descriptions of the lightning environment and vehicle protection technical processes are presented. More specific aerospace vehicle requirements for lightning protection design, performance, and interface characteristics are available upon request to the MSFC Electromagnetics and Aerospace Environments Branch, mail code EL23.

  2. EpiHosp: A web-based visualization tool enabling the exploratory analysis of complications of implantable medical devices from a nationwide hospital database.

    PubMed

    Ficheur, Grégoire; Ferreira Careira, Lionel; Beuscart, Régis; Chazard, Emmanuel

    2015-01-01

    Administrative data can be used for the surveillance of the outcomes of implantable medical devices (IMDs). The objective of this work is to build a web-based tool allowing for an exploratory analysis of time-dependent events that may occur after the implementation of an IMD. This tool should enable a pharmacoepidemiologist to explore on the fly the relationship between a given IMD and a potential outcome. This tool mine the French nationwide database of inpatient stays from 2008 to 2013. The data are preprocessed in order to optimize the queries. A web tool is developed in PHP, MySQL and Javascript. The user selects one or a group of IMD from a tree, and can filter the results using years and hospital names. Four result pages describe the selected inpatient stays: (1) temporal and demographic description, (2) a description of the geographical location of the hospital, (3) a description of the geographical place of residence of the patient and (4) a table showing the rehospitalization reasons by decreasing order of frequency. Then, the user can select one readmission reason and display dynamically the probability of readmission by mean of a Kaplan-Meier curve with confidence intervals. This tool enables to dynamically monitor the occurrence of time-dependent complications of IMD.

  3. Reconstruction of bony facial contour deficiencies with polymethylmethacrylate implants: case report

    PubMed Central

    ABDO FILHO, Ruy C. C.; OLIVEIRA, Thais M.; LOURENÇO, Natalino; GURGEL, Carla; ABDO, Ruy C.C.

    2011-01-01

    Facial trauma can be considered one of the most serious aggressions found in the medical centers due to the emotional consequences and the possibility of deformity. In craniofacial surgery, the use of autologous bone is still the first choice for reconstructing bony defects or irregularities. When there is a shortage of donor bone or a patient refuses an intracranial operation, alloplastic materials such as polymethylmethacrylate (PMMA) can be used. The PMMA prosthesis can be pre-fabricated, bringing advantages such as reduction of surgical time, easy technical handling and good esthetic results. This paper describes the procedures for rehabilitating a patient with PMMA implants in the region of the face, recovering the facial contours and esthetics of the patient. PMID:21952926

  4. Thermionic fuel element for the S-prime reactor

    NASA Astrophysics Data System (ADS)

    Van Hagan, Thomas H.; Drees, Elizabeth A.

    1993-01-01

    Technical aspects of the thermionic fuel element (TFE) design proposed for the S-PRIME space nuclear power system are discussed. Topics covered include the rational for selecting a multicell TFE approach, a technical description of the S-PRIME TFE and its estimated performance, and the technology readiness of the design, which emphasizes techology maturity and low risk.

  5. Creating Pathways for Low-Skill Adults: Lessons for Community and Technical Colleges from a Statewide Longitudinal Study

    ERIC Educational Resources Information Center

    Perry, Carol A.

    2012-01-01

    The purpose of this study was to examine the educational experiences and outcomes of low-skill adults in West Virginia's community and technical colleges, providing a more detailed profile of these students. Data for the variables were obtained from archival databases through a cooperative agreement between state agencies. Descriptive statistics…

  6. A Descriptive Study of the Classroom Instruction Component of the ESEA Title VII Bilingual Education Program. Technical Report.

    ERIC Educational Resources Information Center

    Cardenas, Rene F.; And Others

    The technical report portion of a national survey of bilingual education programs funded under Title VII of the Elementary and Secondary Education Act is presented. The study, conducted during 1979-83, describes the characteristics of the programs' classroom instruction component. Basic project directors and parent advisory committee chairpersons…

  7. Fiscal Year 1986 Technical Objective Document (TOD).

    DTIC Science & Technology

    1986-03-01

    abilties superior to other IR and manual turrets. - START DATE: FY 88 END DATE: FY 90" PROJECT TITLE: COMPOSITE METAL FIRES EE 62:06 JON: 2673XXXX...TECHNOLOGY: FIRE ELEMENT: INTERACTION DESCRIPTION (TECHNICAL OBJECTIVE) Evaluate a new series of agents "BORALONS" capable of extinguishing metal fires and...PROJECT TITLE: COMPOSITE METAL FIRES PE: 63723 JON: 2104XXXX

  8. The Pacific Northwest region vegetation and monitoring system.

    Treesearch

    Timothy A. Max; Hans T. Schreuder; John W. Hazard; Daniel D. Oswald; John Teply; Jim. Alegria

    1996-01-01

    A grid sampling strategy was adopted for broad-scale inventory and monitoring of forest and range vegetation on National Forest System lands in the Pacific North-west Region, USDA Forest Service. This paper documents the technical details of the adopted design and discusses alternative sampling designs that were considered. A less technical description of the selected...

  9. Technical Report on Manpower Planning. Technical Group Report No. 7.

    ERIC Educational Resources Information Center

    Montana Commission on Post-Secondary Education, Helena.

    The report is one of a series containing data and recommendations relevant to the task of developing future plans for Montana's post-secondary education. A brief introduction outlines the methods used in gathering information on manpower needs, and is followed by a review and summarization of the data collected, including a description, analysis,…

  10. Technical Assistance and Training from the Document Design Project. Final Report.

    ERIC Educational Resources Information Center

    American Institutes for Research, Washington, DC.

    Contained in this report is a description of the technical assistance and training phase of the Document Design Project, a program funded by the National Institute of Education and intended to address and correct the readability problems posed by public documents. The first section of the report provides background material on the assistance and…

  11. Sociometric Clique Identification. Final Report.

    ERIC Educational Resources Information Center

    Kadushin, Charles

    This report consists of four parts. The first part is a non-technical summary of the basic problem and an attempted solution. The second part is a technical review of the literature and a description of the basic algorithm used in the solution. The third part describes the use of the Sociogram System. The fourth part describes the use of CHAIN, a…

  12. High School Career and Technical Education Participation and Initial College Enrollment: Evidence from Arkansas

    ERIC Educational Resources Information Center

    Dougherty, Shaun M.

    2016-01-01

    This paper uses rich administrative data from Arkansas to understand whether and how high school career and technical education (CTE) programs are related to initial enrollment in college after high school. This descriptive work is designed to inform how other state and local policymakers understand the potential role of high school CTE…

  13. Third Progress and Information Report of the Vocational-Technical Education Consortium of States.

    ERIC Educational Resources Information Center

    Lee, Connie W.; And Others

    This description of major activities and accomplishments of the Vocational-Technical Education Consortium of the States (V-TECS) since the second progress report of May, 1975, is designed to provide the reader with a basic understanding of the processes and procedures used by the consortium in achieving its major goal: The production of catalogs…

  14. Upward Mobility Programs in the Service Sector for Disadvantaged and Dislocated Workers. Volume II: Technical Appendices.

    ERIC Educational Resources Information Center

    Tao, Fumiyo; And Others

    This volume contains technical and supporting materials that supplement Volume I, which describes upward mobility programs for disadvantaged and dislocated workers in the service sector. Appendix A is a detailed description of the project methodology, including data collection methods and information on data compilation, processing, and analysis.…

  15. The Impact of Career and Technical Education on Native American Males

    ERIC Educational Resources Information Center

    Neilson, Brent Alan

    2016-01-01

    The results of this qualitative descriptive study provide insight into the impact Career and Technical Education has on Native American male students in Northern Arizona. This study was created in response to the lack of research, especially qualitative research in this area. Moreover, it provided Native youth an opportunity to share their stories…

  16. Technical writing practically unified through industry

    NASA Technical Reports Server (NTRS)

    Houston, L. S.

    1981-01-01

    General background details in the development of a university level technical writing program, based upon the writing tasks of the student's occupations, are summarized. Objectives and methods for unifying the courses of study with the needs of industry are discussed. Four academic course divisions, Industries Technologies, in which preparation and training are offered are: Animal, Horticulture, Agriculture, and Agricultural Business. Occupational competence is cited as the main goal for these programs in which technical writing is to be practically unified through industry. Course descriptions are also provided.

  17. Intramedullary Mg2Ag nails augment callus formation during fracture healing in mice.

    PubMed

    Jähn, Katharina; Saito, Hiroaki; Taipaleenmäki, Hanna; Gasser, Andreas; Hort, Norbert; Feyerabend, Frank; Schlüter, Hartmut; Rueger, Johannes M; Lehmann, Wolfgang; Willumeit-Römer, Regine; Hesse, Eric

    2016-05-01

    Intramedullary stabilization is frequently used to treat long bone fractures. Implants usually remain unless complications arise. Since implant removal can become technically very challenging with the potential to cause further tissue damage, biodegradable materials are emerging as alternative options. Magnesium (Mg)-based biodegradable implants have a controllable degradation rate and good tissue compatibility, which makes them attractive for musculoskeletal research. Here we report for the first time the implantation of intramedullary nails made of an Mg alloy containing 2% silver (Mg2Ag) into intact and fractured femora of mice. Prior in vitro analyses revealed an inhibitory effect of Mg2Ag degradation products on osteoclast differentiation and function with no impair of osteoblast function. In vivo, Mg2Ag implants degraded under non-fracture and fracture conditions within 210days and 133days, respectively. During fracture repair, osteoblast function and subsequent bone formation were enhanced, while osteoclast activity and bone resorption were decreased, leading to an augmented callus formation. We observed a widening of the femoral shaft under steady state and regenerating conditions, which was at least in part due to an uncoupled bone remodeling. However, Mg2Ag implants did not cause any systemic adverse effects. These data suggest that Mg2Ag implants might be promising for intramedullary fixation of long bone fractures, a novel concept that has to be further investigated in future studies. Biodegradable implants are promising alternatives to standard steel or titanium implants to avoid implant removal after fracture healing. We therefore developed an intramedullary nail using a novel biodegradable magnesium-silver-alloy (Mg2Ag) and investigated the in vitro and in vivo effects of the implants on bone remodeling under steady state and fracture healing conditions in mice. Our results demonstrate that intramedullary Mg2Ag nails degrade in vivo over time without causing adverse effects. Importantly, radiographs, μCT and bone histomorphometry revealed a significant increase in callus size due to an augmented bone formation rate and a reduced bone resorption in fractures supported by Mg2Ag nails, thereby improving bone healing. Thus, intramedullary Mg2Ag nails are promising biomaterials for fracture healing to circumvent implant removal. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  18. Simplified procedure for the immediate loading of a complete fixed prosthesis supported by four implants in the maxillary jaw: a 2-year prospective study.

    PubMed

    Piano, Sergio; Romeo, Eugenio; Sbricoli, Luca; Pisoni, Gianluca; Cea, Niccoló; Lops, Diego

    2016-12-01

    The aim of this study was to verify the reliability of a system for the fixed retention of complete maxillary prostheses supported by four implants with a follow-up of 2 years. Patients were treated between September 2009 and December 2010 with four Straumann Bone Level SLActive implants supporting a complete prosthesis (CPs). The two distal implants were positioned mesially to the maxillary sinus and with a mesio-distal inclination ≤ 30° in order to reduce the distal prosthesis cantilever. An immediate loading surgical protocol was used. The CPs were planned to be fixed to multibase abutments to test their retention for a fixed rehabilitation. Clinical and radiographic parameters as probing pocket depth (PPD), bleeding score (mBI), plaque index (PI), and marginal bone loss (MBL) were assessed at a 1- and 2-year follow-up visits. Moreover, any biological and prosthodontic maintenance events were recorded. Clinical and radiographic parameters changes were analyzed. Twenty-one patients treated with a total of 84 implants completed the 2-year examination period. Four patients were lost to follow up. No technical complication was recorded. Also, no implant, reconstruction, or abutment failures were observed. Therefore, an implant and prosthetic survival rate of 100% were achieved after 2 years. The mean periodontal parameter scores after 2 years of function were 2.6 mm for PPD (SD 0.8 mm), 0.3 for mBI (SD 0.5 mm), and 1.2 for PI (SD 0.4 mm) indexes, respectively. In addition, the mean MBL score measured at the 2-year follow-up visit was -0.34 mm (SD of -0.45 mm). Furthermore, no peri-implant soft tissue inflammation or peri-implant infection was observed. It has been shown that immediate loading of four implants positioned anteriorly to the maxillary sinus could be a reliable treatment procedure to support fixed complete restorations. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Technology and development requirements for advanced coal conversion systems

    NASA Technical Reports Server (NTRS)

    1981-01-01

    A compendium of coal conversion process descriptions is presented. The SRS and MC data bases were utilized to provide information paticularly in the areas of existing process designs and process evaluations. Additional information requirements were established and arrangements were made to visit process developers, pilot plants, and process development units to obtain information that was not otherwise available. Plant designs, process descriptions and operating conditions, and performance characteristics were analyzed and requirements for further development identified and evaluated to determine the impact of these requirements on the process commercialization potential from the standpoint of economics and technical feasibility. A preliminary methodology was established for the comparative technical and economic assessment of advanced processes.

  20. Aircraft/Air Traffic Management Functional Analysis Model: Technical Description. 2.0

    NASA Technical Reports Server (NTRS)

    Etheridge, Melvin; Plugge, Joana; Retina, Nusrat

    1998-01-01

    The Aircraft/Air Traffic Management Functional Analysis Model, Version 2.0 (FAM 2.0), is a discrete event simulation model designed to support analysis of alternative concepts in air traffic management and control. FAM 2.0 was developed by the Logistics Management Institute (LMI) under a National Aeronautics and Space Administration (NASA) contract. This document provides a technical description of FAM 2.0 and its computer files to enable the modeler and programmer to make enhancements or modifications to the model. Those interested in a guide for using the model in analysis should consult the companion document, Aircraft/Air Traffic Management Functional Analysis Model, Version 2.0 Users Manual.

Top