Sample records for importance sampling techniques

  1. Screen Space Ambient Occlusion Based Multiple Importance Sampling for Real-Time Rendering

    NASA Astrophysics Data System (ADS)

    Zerari, Abd El Mouméne; Babahenini, Mohamed Chaouki

    2018-03-01

    We propose a new approximation technique for accelerating the Global Illumination algorithm for real-time rendering. The proposed approach is based on the Screen-Space Ambient Occlusion (SSAO) method, which approximates the global illumination for large, fully dynamic scenes at interactive frame rates. Current algorithms that are based on the SSAO method suffer from difficulties due to the large number of samples that are required. In this paper, we propose an improvement to the SSAO technique by integrating it with a Multiple Importance Sampling technique that combines a stratified sampling method with an importance sampling method, with the objective of reducing the number of samples. Experimental evaluation demonstrates that our technique can produce high-quality images in real time and is significantly faster than traditional techniques.

  2. The Importance of Introductory Statistics Students Understanding Appropriate Sampling Techniques

    ERIC Educational Resources Information Center

    Menil, Violeta C.

    2005-01-01

    In this paper the author discusses the meaning of sampling, the reasons for sampling, the Central Limit Theorem, and the different techniques of sampling. Practical and relevant examples are given to make the appropriate sampling techniques understandable to students of Introductory Statistics courses. With a thorough knowledge of sampling…

  3. A new approach to importance sampling for the simulation of false alarms. [in radar systems

    NASA Technical Reports Server (NTRS)

    Lu, D.; Yao, K.

    1987-01-01

    In this paper a modified importance sampling technique for improving the convergence of Importance Sampling is given. By using this approach to estimate low false alarm rates in radar simulations, the number of Monte Carlo runs can be reduced significantly. For one-dimensional exponential, Weibull, and Rayleigh distributions, a uniformly minimum variance unbiased estimator is obtained. For Gaussian distribution the estimator in this approach is uniformly better than that of previously known Importance Sampling approach. For a cell averaging system, by combining this technique and group sampling, the reduction of Monte Carlo runs for a reference cell of 20 and false alarm rate of lE-6 is on the order of 170 as compared to the previously known Importance Sampling approach.

  4. Improved importance sampling technique for efficient simulation of digital communication systems

    NASA Technical Reports Server (NTRS)

    Lu, Dingqing; Yao, Kung

    1988-01-01

    A new, improved importance sampling (IIS) approach to simulation is considered. Some basic concepts of IS are introduced, and detailed evolutions of simulation estimation variances for Monte Carlo (MC) and IS simulations are given. The general results obtained from these evolutions are applied to the specific previously known conventional importance sampling (CIS) technique and the new IIS technique. The derivation for a linear system with no signal random memory is considered in some detail. For the CIS technique, the optimum input scaling parameter is found, while for the IIS technique, the optimum translation parameter is found. The results are generalized to a linear system with memory and signals. Specific numerical and simulation results are given which show the advantages of CIS over MC and IIS over CIS for simulations of digital communications systems.

  5. Bayesian techniques for surface fuel loading estimation

    Treesearch

    Kathy Gray; Robert Keane; Ryan Karpisz; Alyssa Pedersen; Rick Brown; Taylor Russell

    2016-01-01

    A study by Keane and Gray (2013) compared three sampling techniques for estimating surface fine woody fuels. Known amounts of fine woody fuel were distributed on a parking lot, and researchers estimated the loadings using different sampling techniques. An important result was that precise estimates of biomass required intensive sampling for both the planar intercept...

  6. Active learning for semi-supervised clustering based on locally linear propagation reconstruction.

    PubMed

    Chang, Chin-Chun; Lin, Po-Yi

    2015-03-01

    The success of semi-supervised clustering relies on the effectiveness of side information. To get effective side information, a new active learner learning pairwise constraints known as must-link and cannot-link constraints is proposed in this paper. Three novel techniques are developed for learning effective pairwise constraints. The first technique is used to identify samples less important to cluster structures. This technique makes use of a kernel version of locally linear embedding for manifold learning. Samples neither important to locally linear propagation reconstructions of other samples nor on flat patches in the learned manifold are regarded as unimportant samples. The second is a novel criterion for query selection. This criterion considers not only the importance of a sample to expanding the space coverage of the learned samples but also the expected number of queries needed to learn the sample. To facilitate semi-supervised clustering, the third technique yields inferred must-links for passing information about flat patches in the learned manifold to semi-supervised clustering algorithms. Experimental results have shown that the learned pairwise constraints can capture the underlying cluster structures and proven the feasibility of the proposed approach. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Using Candy Samples to Learn about Sampling Techniques and Statistical Data Evaluation

    ERIC Educational Resources Information Center

    Canaes, Larissa S.; Brancalion, Marcel L.; Rossi, Adriana V.; Rath, Susanne

    2008-01-01

    A classroom exercise for undergraduate and beginning graduate students that takes about one class period is proposed and discussed. It is an easy, interesting exercise that demonstrates important aspects of sampling techniques (sample amount, particle size, and the representativeness of the sample in relation to the bulk material). The exercise…

  8. Arsenic, Antimony, Chromium, and Thallium Speciation in Water and Sediment Samples with the LC-ICP-MS Technique

    PubMed Central

    Jabłońska-Czapla, Magdalena

    2015-01-01

    Chemical speciation is a very important subject in the environmental protection, toxicology, and chemical analytics due to the fact that toxicity, availability, and reactivity of trace elements depend on the chemical forms in which these elements occur. Research on low analyte levels, particularly in complex matrix samples, requires more and more advanced and sophisticated analytical methods and techniques. The latest trends in this field concern the so-called hyphenated techniques. Arsenic, antimony, chromium, and (underestimated) thallium attract the closest attention of toxicologists and analysts. The properties of those elements depend on the oxidation state in which they occur. The aim of the following paper is to answer the question why the speciation analytics is so important. The paper also provides numerous examples of the hyphenated technique usage (e.g., the LC-ICP-MS application in the speciation analysis of chromium, antimony, arsenic, or thallium in water and bottom sediment samples). An important issue addressed is the preparation of environmental samples for speciation analysis. PMID:25873962

  9. Applications of surface analytical techniques in Earth Sciences

    NASA Astrophysics Data System (ADS)

    Qian, Gujie; Li, Yubiao; Gerson, Andrea R.

    2015-03-01

    This review covers a wide range of surface analytical techniques: X-ray photoelectron spectroscopy (XPS), scanning photoelectron microscopy (SPEM), photoemission electron microscopy (PEEM), dynamic and static secondary ion mass spectroscopy (SIMS), electron backscatter diffraction (EBSD), atomic force microscopy (AFM). Others that are relatively less widely used but are also important to the Earth Sciences are also included: Auger electron spectroscopy (AES), low energy electron diffraction (LEED) and scanning tunnelling microscopy (STM). All these techniques probe only the very top sample surface layers (sub-nm to several tens of nm). In addition, we also present several other techniques i.e. Raman microspectroscopy, reflection infrared (IR) microspectroscopy and quantitative evaluation of minerals by scanning electron microscopy (QEMSCAN) that penetrate deeper into the sample, up to several μm, as all of them are fundamental analytical tools for the Earth Sciences. Grazing incidence synchrotron techniques, sensitive to surface measurements, are also briefly introduced at the end of this review. (Scanning) transmission electron microscopy (TEM/STEM) is a special case that can be applied to characterisation of mineralogical and geological sample surfaces. Since TEM/STEM is such an important technique for Earth Scientists, we have also included it to draw attention to the capability of TEM/STEM applied as a surface-equivalent tool. While this review presents most of the important techniques for the Earth Sciences, it is not an all-inclusive bibliography of those analytical techniques. Instead, for each technique that is discussed, we first give a very brief introduction about its principle and background, followed by a short section on approaches to sample preparation that are important for researchers to appreciate prior to the actual sample analysis. We then use examples from publications (and also some of our known unpublished results) within the Earth Sciences to show how each technique is applied and used to obtain specific information and to resolve real problems, which forms the central theme of this review. Although this review focuses on applications of these techniques to study mineralogical and geological samples, we also anticipate that researchers from other research areas such as Material and Environmental Sciences may benefit from this review.

  10. An Overview of Importance Splitting for Rare Event Simulation

    ERIC Educational Resources Information Center

    Morio, Jerome; Pastel, Rudy; Le Gland, Francois

    2010-01-01

    Monte Carlo simulations are a classical tool to analyse physical systems. When unlikely events are to be simulated, the importance sampling technique is often used instead of Monte Carlo. Importance sampling has some drawbacks when the problem dimensionality is high or when the optimal importance sampling density is complex to obtain. In this…

  11. A field test of cut-off importance sampling for bole volume

    Treesearch

    Jeffrey H. Gove; Harry T. Valentine; Michael J. Holmes

    2000-01-01

    Cut-off importance sampling has recently been introduced as a technique for estimating bole volume to some point below the tree tip, termed the cut-off point. A field test of this technique was conducted on a small population of eastern white pine trees using dendrometry as the standard for volume estimation. Results showed that the differences in volume estimates...

  12. Applications of infrared photo-acoustic spectroscopy for wood samples

    Treesearch

    Mon-Lin Kuo; John F. McClelland; Siquan Luo; Po-Liang Chien; R.D. Walker; Chung-Yun Hse

    1988-01-01

    Various infrared (IR) spectroscopic techniques for the analysis of wood samples are briefly discussed. Theories and instrumentation of the newly developed photoacoustic spectroscopic (PAS) technique for measuring absorbance spectra of solids are presented. Some important applications of the PAS technique in wood science research are discussed. The application of the...

  13. Nuclear Ensemble Approach with Importance Sampling.

    PubMed

    Kossoski, Fábris; Barbatti, Mario

    2018-06-12

    We show that the importance sampling technique can effectively augment the range of problems where the nuclear ensemble approach can be applied. A sampling probability distribution function initially determines the collection of initial conditions for which calculations are performed, as usual. Then, results for a distinct target distribution are computed by introducing compensating importance sampling weights for each sampled point. This mapping between the two probability distributions can be performed whenever they are both explicitly constructed. Perhaps most notably, this procedure allows for the computation of temperature dependent observables. As a test case, we investigated the UV absorption spectra of phenol, which has been shown to have a marked temperature dependence. Application of the proposed technique to a range that covers 500 K provides results that converge to those obtained with conventional sampling. We further show that an overall improved rate of convergence is obtained when sampling is performed at intermediate temperatures. The comparison between calculated and the available measured cross sections is very satisfactory, as the main features of the spectra are correctly reproduced. As a second test case, one of Tully's classical models was revisited, and we show that the computation of dynamical observables also profits from the importance sampling technique. In summary, the strategy developed here can be employed to assess the role of temperature for any property calculated within the nuclear ensemble method, with the same computational cost as doing so for a single temperature.

  14. Comparative study of nail sampling techniques in onychomycosis.

    PubMed

    Shemer, Avner; Davidovici, Batya; Grunwald, Marcelo H; Trau, Henri; Amichai, Boaz

    2009-07-01

    Onychomycosis is a common problem. Obtaining accurate laboratory test results before treatment is important in clinical practice. The purpose of this study was to compare results of curettage and drilling techniques of nail sampling in the diagnosis of onychomycosis, and to establish the best technique and location of sampling. We evaluated 60 patients suffering from distal and lateral subungual onychomycosis and lateral subungual onychomycosis using curettage and vertical and horizontal drilling sampling techniques from three different sites of the infected nail. KOH examination and fungal culture were used for detection and identification of fungal infection. At each sample site, the horizontal drilling technique has a better culture sensitivity than curettage. Trichophyton rubrum was by far the most common pathogen detected by both techniques from all sampling sites. The drilling technique was found to be statistically better than curettage at each site of sampling, furthermore vertical drilling from the proximal part of the affected nail was found to be the best procedure for nail sampling. With each technique we found that the culture sensitivity improved as the location of the sample was more proximal. More types of pathogens were detected in samples taken by both methods from proximal parts of the affected nails.

  15. Data in support of the detection of genetically modified organisms (GMOs) in food and feed samples.

    PubMed

    Alasaad, Noor; Alzubi, Hussein; Kader, Ahmad Abdul

    2016-06-01

    Food and feed samples were randomly collected from different sources, including local and imported materials from the Syrian local market. These included maize, barley, soybean, fresh food samples and raw material. GMO detection was conducted by PCR and nested PCR-based techniques using specific primers for the most used foreign DNA commonly used in genetic transformation procedures, i.e., 35S promoter, T-nos, epsps, cryIA(b) gene and nptII gene. The results revealed for the first time in Syria the presence of GM foods and feeds with glyphosate-resistant trait of P35S promoter and NOS terminator in the imported soybean samples with high frequency (5 out of the 6 imported soybean samples). While, tests showed negative results for the local samples. Also, tests revealed existence of GMOs in two imported maize samples detecting the presence of 35S promoter and nos terminator. Nested PCR results using two sets of primers confirmed our data. The methods applied in the brief data are based on DNA analysis by Polymerase Chain Reaction (PCR). This technique is specific, practical, reproducible and sensitive enough to detect up to 0.1% GMO in food and/or feedstuffs. Furthermore, all of the techniques mentioned are economic and can be applied in Syria and other developing countries. For all these reasons, the DNA-based analysis methods were chosen and preferred over protein-based analysis.

  16. Studying the spatial variability of Cr in agricultural field using both particle induced X-ray emission (PIXE) and instrumental neutron activation analysis (INAA) technique

    NASA Astrophysics Data System (ADS)

    Cruvinel, Paulo E.; Crestana, Sílvio; Artaxo, Paulo; Martins, JoséV.; Armelin, Maria JoséA.

    1996-04-01

    In the field of soil physics, a technique which permits a non-destructive, accurate and fast elemental analysis with a minimum of sample preparation effort is often desired. Although trace elements are minor components of the solid phase, they play an important role in soil fertility. Cr is of nutritional importance because it is a required element in human and animal nutrition. The immobility of Cr may be responsible for an inadequate Cr supply to plants. This work not only demonstrates the suitability of PIXE as a fast and non-destructive technique, useful to measure Cr content in soil samples, but also outlines a study of spatial variability of that element in agricultural field. To demonstrate the capability of the method soil samples were collected in a 5000 m 2 agricultural field. The soil samples were analyzed using both PIXE and INAA techniques. Besides, a Fourier interpolation technique was used to verify the distribution of Cr along of the sampled field. INAA was carried out by means of the γ-ray emitted by 51Cr(320 keV). Results show that there is a good linear relationship between the elemental concentration of Cr obtained using those techniques, i.e. a correlation coefficient of r2 = 0.82 was achieved.

  17. GROUND WATER SAMPLING USING LOW-FLOW TECHNIQUES

    EPA Science Inventory

    Obtaining representative ground water samples is important for site assessment and remedial performance monitoring objectives. The sampling device or method used to collect samples from monitoring or compliance well can significantly impact data quality and reliability. Low-flo...

  18. Analysis of defect structure in silicon. Characterization of samples from UCP ingot 5848-13C

    NASA Technical Reports Server (NTRS)

    Natesh, R.; Guyer, T.; Stringfellow, G. B.

    1982-01-01

    Statistically significant quantitative structural imperfection measurements were made on samples from ubiquitous crystalline process (UCP) Ingot 5848 - 13 C. Important trends were noticed between the measured data, cell efficiency, and diffusion length. Grain boundary substructure appears to have an important effect on the conversion efficiency of solar cells from Semix material. Quantitative microscopy measurements give statistically significant information compared to other microanalytical techniques. A surface preparation technique to obtain proper contrast of structural defects suitable for QTM analysis was perfected.

  19. Sample preparation techniques for the determination of trace residues and contaminants in foods.

    PubMed

    Ridgway, Kathy; Lalljie, Sam P D; Smith, Roger M

    2007-06-15

    The determination of trace residues and contaminants in complex matrices, such as food, often requires extensive sample extraction and preparation prior to instrumental analysis. Sample preparation is often the bottleneck in analysis and there is a need to minimise the number of steps to reduce both time and sources of error. There is also a move towards more environmentally friendly techniques, which use less solvent and smaller sample sizes. Smaller sample size becomes important when dealing with real life problems, such as consumer complaints and alleged chemical contamination. Optimal sample preparation can reduce analysis time, sources of error, enhance sensitivity and enable unequivocal identification, confirmation and quantification. This review considers all aspects of sample preparation, covering general extraction techniques, such as Soxhlet and pressurised liquid extraction, microextraction techniques such as liquid phase microextraction (LPME) and more selective techniques, such as solid phase extraction (SPE), solid phase microextraction (SPME) and stir bar sorptive extraction (SBSE). The applicability of each technique in food analysis, particularly for the determination of trace organic contaminants in foods is discussed.

  20. Development and application of mass spectrometric techniques for ultra-trace determination of 236U in environmental samples-A review.

    PubMed

    Bu, Wenting; Zheng, Jian; Ketterer, Michael E; Hu, Sheng; Uchida, Shigeo; Wang, Xiaolin

    2017-12-01

    Measurements of the long-lived radionuclide 236 U are an important endeavor, not only in nuclear safeguards work, but also in terms of using this emerging nuclide as a tracer in chemical oceanography, hydrology, and actinide sourcing. Depending on the properties of a sample and its neutron irradiation history, 236 U/ 238 U ratios from different sources vary significantly. Therefore, this ratio can be treated as an important fingerprint for radioactive source identification, and in particular, affords a definitive means of discriminating between naturally occurring U and specific types of anthropogenic U. The development of mass spectrometric techniques makes it possible to determine ultra-trace levels of 236 U in environmental samples. In this paper, we review the current status of mass spectrometric approaches for determination of 236 U in environmental samples. Various sample preparation methods are summarized and compared. The mass spectrometric techniques emphasized herein are thermal ionization mass spectrometry (TIMS), inductively coupled plasma mass spectrometry (ICP-MS) and accelerator mass spectrometry (AMS). The strategies or principles used by each technique for the analysis of 236 U are described. The performances of these techniques in terms of abundance sensitivity and detection limit are discussed in detail. To date, AMS exhibits the best capability for ultra-trace determinations of 236 U. The levels and behaviors of 236 U in various environmental media are summarized and discussed as well. Results suggest that 236 U has an important, emerging role as a tracer for geochemical studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. A Critical Review on Clinical Application of Separation Techniques for Selective Recognition of Uracil and 5-Fluorouracil.

    PubMed

    Pandey, Khushaboo; Dubey, Rama Shankar; Prasad, Bhim Bali

    2016-03-01

    The most important objectives that are frequently found in bio-analytical chemistry involve applying tools to relevant medical/biological problems and refining these applications. Developing a reliable sample preparation step, for the medical and biological fields is another primary objective in analytical chemistry, in order to extract and isolate the analytes of interest from complex biological matrices. Since, main inborn errors of metabolism (IEM) diagnosable through uracil analysis and the therapeutic monitoring of toxic 5-fluoruracil (an important anti-cancerous drug) in dihydropyrimidine dehydrogenase deficient patients, require an ultra-sensitive, reproducible, selective, and accurate analytical techniques for their measurements. Therefore, keeping in view, the diagnostic value of uracil and 5-fluoruracil measurements, this article refines several analytical techniques involved in selective recognition and quantification of uracil and 5-fluoruracil from biological and pharmaceutical samples. The prospective study revealed that implementation of molecularly imprinted polymer as a solid-phase material for sample preparation and preconcentration of uracil and 5-fluoruracil had proven to be effective as it could obviates problems related to tedious separation techniques, owing to protein binding and drastic interferences, from the complex matrices in real samples such as blood plasma, serum samples.

  2. A comparison of cover calculation techniques for relating point-intercept vegetation sampling to remote sensing imagery

    USDA-ARS?s Scientific Manuscript database

    Accurate and timely spatial predictions of vegetation cover from remote imagery are an important data source for natural resource management. High-quality in situ data are needed to develop and validate these products. Point-intercept sampling techniques are a common method for obtaining quantitativ...

  3. Solid Phase Microextraction and Related Techniques for Drugs in Biological Samples

    PubMed Central

    Moein, Mohammad Mahdi; Said, Rana; Bassyouni, Fatma

    2014-01-01

    In drug discovery and development, the quantification of drugs in biological samples is an important task for the determination of the physiological performance of the investigated drugs. After sampling, the next step in the analytical process is sample preparation. Because of the low concentration levels of drug in plasma and the variety of the metabolites, the selected extraction technique should be virtually exhaustive. Recent developments of sample handling techniques are directed, from one side, toward automatization and online coupling of sample preparation units. The primary objective of this review is to present the recent developments in microextraction sample preparation methods for analysis of drugs in biological fluids. Microextraction techniques allow for less consumption of solvent, reagents, and packing materials, and small sample volumes can be used. In this review the use of solid phase microextraction (SPME), microextraction in packed sorbent (MEPS), and stir-bar sorbtive extraction (SBSE) in drug analysis will be discussed. In addition, the use of new sorbents such as monoliths and molecularly imprinted polymers will be presented. PMID:24688797

  4. Estimation variance bounds of importance sampling simulations in digital communication systems

    NASA Technical Reports Server (NTRS)

    Lu, D.; Yao, K.

    1991-01-01

    In practical applications of importance sampling (IS) simulation, two basic problems are encountered, that of determining the estimation variance and that of evaluating the proper IS parameters needed in the simulations. The authors derive new upper and lower bounds on the estimation variance which are applicable to IS techniques. The upper bound is simple to evaluate and may be minimized by the proper selection of the IS parameter. Thus, lower and upper bounds on the improvement ratio of various IS techniques relative to the direct Monte Carlo simulation are also available. These bounds are shown to be useful and computationally simple to obtain. Based on the proposed technique, one can readily find practical suboptimum IS parameters. Numerical results indicate that these bounding techniques are useful for IS simulations of linear and nonlinear communication systems with intersymbol interference in which bit error rate and IS estimation variances cannot be obtained readily using prior techniques.

  5. Testing sample stability using four storage methods and the macroalgae Ulva and Gracilaria

    EPA Science Inventory

    Concern over the relative importance of different sample preparation and storage techniques frequently used in stable isotope analysis of particulate nitrogen (δ15N) and carbon (δ13C) prompted an experiment to determine how important such factors were to measured values in marine...

  6. A Coordinated Focused Ion Beam/Ultramicrotomy Technique for Serial Sectioning of Hayabusa Particles and Other Returned Samples

    NASA Technical Reports Server (NTRS)

    Berger, E. L.; Keller, L. P.

    2014-01-01

    Recent sample return missions, such as NASA's Stardust mission to comet 81P/Wild 2 and JAXA's Hayabusa mission to asteroid 25143 Itokawa, have returned particulate samples (typically 5-50 µm) that pose tremendous challenges to coordinated analysis using a variety of nano- and micro-beam techniques. The ability to glean maximal information from individual particles has become increasingly important and depends critically on how the samples are prepared for analysis. This also holds true for other extraterrestrial materials, including interplanetary dust particles, micrometeorites and lunar regolith grains. Traditionally, particulate samples have been prepared using microtomy techniques (e.g., [1]). However, for hard mineral particles ?20 µm, microtome thin sections are compromised by severe chatter and sample loss. For these difficult samples, we have developed a hybrid technique that combines traditional ultramicrotomy with focused ion beam (FIB) techniques, allowing for the in situ investigation of grain surfaces and interiors. Using this method, we have increased the number of FIB-SEM prepared sections that can be recovered from a particle with dimensions on the order of tens of µms. These sections can be subsequently analyzed using a variety of electron beam techniques. Here, we demonstrate this sample preparation technique on individual lunar regolith grains in order to study their space-weathered surfaces. We plan to extend these efforts to analyses of individual Hayabusa samples.

  7. Using Delphi technique in a consensual curriculum for periodontics.

    PubMed

    Fried, Hana; Leao, Anna Thereza

    2007-11-01

    Periodontics has experienced several important conceptual changes in the last few decades. As such, it is important to have a periodontics curriculum built upon the expertise of specialists in that discipline and reflecting those changes. The main goal of this study was to attain a consensus, through the use of the Delphi technique, on the topics that should be included in a periodontics curriculum for undergraduate dental students. A sample of periodontics lecturers from nine dental schools in two Brazilian cities was used, and a Delphi technique approach was followed to investigate sample member perceptions on the subject. Participants received four postal mail questionnaires asking them to rate and rerate eighty-nine topics for possible inclusion in the curriculum. A descriptive analysis was conducted, and topic frequencies were calculated. Topics rated as highly important for inclusion were the following: health, ailment, prevention, etiology, epidemiology, diagnosis, and treatment. The Delphi technique approach proved successful in involving periodontics lecturers in the design of a periodontics curriculum for undergraduate dental students.

  8. Sampling Methods in Cardiovascular Nursing Research: An Overview.

    PubMed

    Kandola, Damanpreet; Banner, Davina; O'Keefe-McCarthy, Sheila; Jassal, Debbie

    2014-01-01

    Cardiovascular nursing research covers a wide array of topics from health services to psychosocial patient experiences. The selection of specific participant samples is an important part of the research design and process. The sampling strategy employed is of utmost importance to ensure that a representative sample of participants is chosen. There are two main categories of sampling methods: probability and non-probability. Probability sampling is the random selection of elements from the population, where each element of the population has an equal and independent chance of being included in the sample. There are five main types of probability sampling including simple random sampling, systematic sampling, stratified sampling, cluster sampling, and multi-stage sampling. Non-probability sampling methods are those in which elements are chosen through non-random methods for inclusion into the research study and include convenience sampling, purposive sampling, and snowball sampling. Each approach offers distinct advantages and disadvantages and must be considered critically. In this research column, we provide an introduction to these key sampling techniques and draw on examples from the cardiovascular research. Understanding the differences in sampling techniques may aid nurses in effective appraisal of research literature and provide a reference pointfor nurses who engage in cardiovascular research.

  9. Advances in paper-based sample pretreatment for point-of-care testing.

    PubMed

    Tang, Rui Hua; Yang, Hui; Choi, Jane Ru; Gong, Yan; Feng, Shang Sheng; Pingguan-Murphy, Belinda; Huang, Qing Sheng; Shi, Jun Ling; Mei, Qi Bing; Xu, Feng

    2017-06-01

    In recent years, paper-based point-of-care testing (POCT) has been widely used in medical diagnostics, food safety and environmental monitoring. However, a high-cost, time-consuming and equipment-dependent sample pretreatment technique is generally required for raw sample processing, which are impractical for low-resource and disease-endemic areas. Therefore, there is an escalating demand for a cost-effective, simple and portable pretreatment technique, to be coupled with the commonly used paper-based assay (e.g. lateral flow assay) in POCT. In this review, we focus on the importance of using paper as a platform for sample pretreatment. We firstly discuss the beneficial use of paper for sample pretreatment, including sample collection and storage, separation, extraction, and concentration. We highlight the working principle and fabrication of each sample pretreatment device, the existing challenges and the future perspectives for developing paper-based sample pretreatment technique.

  10. Volatile organic compounds: sampling methods and their worldwide profile in ambient air.

    PubMed

    Kumar, Anuj; Víden, Ivan

    2007-08-01

    The atmosphere is a particularly difficult analytical system because of the very low levels of substances to be analysed, sharp variations in pollutant levels with time and location, differences in wind, temperature and humidity. This makes the selection of an efficient sampling technique for air analysis a key step to reliable results. Generally, methods for volatile organic compounds sampling include collection of the whole air or preconcentration of samples on adsorbents. All the methods vary from each other according to the sampling technique, type of sorbent, method of extraction and identification technique. In this review paper we discuss various important aspects for sampling of volatile organic compounds by the widely used and advanced sampling methods. Characteristics of various adsorbents used for VOCs sampling are also described. Furthermore, this paper makes an effort to comprehensively review the concentration levels of volatile organic compounds along with the methodology used for analysis, in major cities of the world.

  11. Performance evaluation of an importance sampling technique in a Jackson network

    NASA Astrophysics Data System (ADS)

    brahim Mahdipour, E.; Masoud Rahmani, Amir; Setayeshi, Saeed

    2014-03-01

    Importance sampling is a technique that is commonly used to speed up Monte Carlo simulation of rare events. However, little is known regarding the design of efficient importance sampling algorithms in the context of queueing networks. The standard approach, which simulates the system using an a priori fixed change of measure suggested by large deviation analysis, has been shown to fail in even the simplest network settings. Estimating probabilities associated with rare events has been a topic of great importance in queueing theory, and in applied probability at large. In this article, we analyse the performance of an importance sampling estimator for a rare event probability in a Jackson network. This article carries out strict deadlines to a two-node Jackson network with feedback whose arrival and service rates are modulated by an exogenous finite state Markov process. We have estimated the probability of network blocking for various sets of parameters, and also the probability of missing the deadline of customers for different loads and deadlines. We have finally shown that the probability of total population overflow may be affected by various deadline values, service rates and arrival rates.

  12. Convergence and Efficiency of Adaptive Importance Sampling Techniques with Partial Biasing

    NASA Astrophysics Data System (ADS)

    Fort, G.; Jourdain, B.; Lelièvre, T.; Stoltz, G.

    2018-04-01

    We propose a new Monte Carlo method to efficiently sample a multimodal distribution (known up to a normalization constant). We consider a generalization of the discrete-time Self Healing Umbrella Sampling method, which can also be seen as a generalization of well-tempered metadynamics. The dynamics is based on an adaptive importance technique. The importance function relies on the weights (namely the relative probabilities) of disjoint sets which form a partition of the space. These weights are unknown but are learnt on the fly yielding an adaptive algorithm. In the context of computational statistical physics, the logarithm of these weights is, up to an additive constant, the free-energy, and the discrete valued function defining the partition is called the collective variable. The algorithm falls into the general class of Wang-Landau type methods, and is a generalization of the original Self Healing Umbrella Sampling method in two ways: (i) the updating strategy leads to a larger penalization strength of already visited sets in order to escape more quickly from metastable states, and (ii) the target distribution is biased using only a fraction of the free-energy, in order to increase the effective sample size and reduce the variance of importance sampling estimators. We prove the convergence of the algorithm and analyze numerically its efficiency on a toy example.

  13. Correlative Techniques in Microscopy

    USDA-ARS?s Scientific Manuscript database

    Imaging is an important component in basic research, product development and understanding structure/function relationships in agricultural commodities and products. An array of microscopes and techniques can be used illustrate the structure and microchemistry of diverse samples. Examples of the var...

  14. Clinical application of microsampling versus conventional sampling techniques in the quantitative bioanalysis of antibiotics: a systematic review.

    PubMed

    Guerra Valero, Yarmarly C; Wallis, Steven C; Lipman, Jeffrey; Stove, Christophe; Roberts, Jason A; Parker, Suzanne L

    2018-03-01

    Conventional sampling techniques for clinical pharmacokinetic studies often require the removal of large blood volumes from patients. This can result in a physiological or emotional burden, particularly for neonates or pediatric patients. Antibiotic pharmacokinetic studies are typically performed on healthy adults or general ward patients. These may not account for alterations to a patient's pathophysiology and can lead to suboptimal treatment. Microsampling offers an important opportunity for clinical pharmacokinetic studies in vulnerable patient populations, where smaller sample volumes can be collected. This systematic review provides a description of currently available microsampling techniques and an overview of studies reporting the quantitation and validation of antibiotics using microsampling. A comparison of microsampling to conventional sampling in clinical studies is included.

  15. Analytical techniques for steroid estrogens in water samples - A review.

    PubMed

    Fang, Ting Yien; Praveena, Sarva Mangala; deBurbure, Claire; Aris, Ahmad Zaharin; Ismail, Sharifah Norkhadijah Syed; Rasdi, Irniza

    2016-12-01

    In recent years, environmental concerns over ultra-trace levels of steroid estrogens concentrations in water samples have increased because of their adverse effects on human and animal life. Special attention to the analytical techniques used to quantify steroid estrogens in water samples is therefore increasingly important. The objective of this review was to present an overview of both instrumental and non-instrumental analytical techniques available for the determination of steroid estrogens in water samples, evidencing their respective potential advantages and limitations using the Need, Approach, Benefit, and Competition (NABC) approach. The analytical techniques highlighted in this review were instrumental and non-instrumental analytical techniques namely gas chromatography mass spectrometry (GC-MS), liquid chromatography mass spectrometry (LC-MS), enzyme-linked immuno sorbent assay (ELISA), radio immuno assay (RIA), yeast estrogen screen (YES) assay, and human breast cancer cell line proliferation (E-screen) assay. The complexity of water samples and their low estrogenic concentrations necessitates the use of highly sensitive instrumental analytical techniques (GC-MS and LC-MS) and non-instrumental analytical techniques (ELISA, RIA, YES assay and E-screen assay) to quantify steroid estrogens. Both instrumental and non-instrumental analytical techniques have their own advantages and limitations. However, the non-instrumental ELISA analytical techniques, thanks to its lower detection limit and simplicity, its rapidity and cost-effectiveness, currently appears to be the most reliable for determining steroid estrogens in water samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Microextraction by packed sorbent: an emerging, selective and high-throughput extraction technique in bioanalysis.

    PubMed

    Pereira, Jorge; Câmara, José S; Colmsjö, Anders; Abdel-Rehim, Mohamed

    2014-06-01

    Sample preparation is an important analytical step regarding the isolation and concentration of desired components from complex matrices and greatly influences their reliable and accurate analysis and data quality. It is the most labor-intensive and error-prone process in analytical methodology and, therefore, may influence the analytical performance of the target analytes quantification. Many conventional sample preparation methods are relatively complicated, involving time-consuming procedures and requiring large volumes of organic solvents. Recent trends in sample preparation include miniaturization, automation, high-throughput performance, on-line coupling with analytical instruments and low-cost operation through extremely low volume or no solvent consumption. Micro-extraction techniques, such as micro-extraction by packed sorbent (MEPS), have these advantages over the traditional techniques. This paper gives an overview of MEPS technique, including the role of sample preparation in bioanalysis, the MEPS description namely MEPS formats (on- and off-line), sorbents, experimental and protocols, factors that affect the MEPS performance, and the major advantages and limitations of MEPS compared with other sample preparation techniques. We also summarize MEPS recent applications in bioanalysis. Copyright © 2014 John Wiley & Sons, Ltd.

  17. A LITERATURE REVIEW OF WIPE SAMPLING METHODS ...

    EPA Pesticide Factsheets

    Wipe sampling is an important technique for the estimation of contaminant deposition in buildings, homes, or outdoor surfaces as a source of possible human exposure. Numerousmethods of wipe sampling exist, and each method has its own specification for the type of wipe, wetting solvent, and determinative step to be used, depending upon the contaminant of concern. The objective of this report is to concisely summarize the findings of a literature review that was conducted to identify the state-of-the-art wipe sampling techniques for a target list of compounds. This report describes the methods used to perform the literature review; a brief review of wipe sampling techniques in general; an analysis of physical and chemical properties of each target analyte; an analysis of wipe sampling techniques for the target analyte list; and asummary of the wipe sampling techniques for the target analyte list, including existing data gaps. In general, no overwhelming consensus can be drawn from the current literature on how to collect a wipe sample for the chemical warfare agents, organophosphate pesticides, and other toxic industrial chemicals of interest to this study. Different methods, media, and wetting solvents have been recommended and used by various groups and different studies. For many of the compounds of interest, no specific wipe sampling methodology has been established for their collection. Before a wipe sampling method (or methods) can be established for the co

  18. Thermal Analysis of Brazing Seal and Sterilizing Technique to Break Contamination Chain for Mars Sample Return

    NASA Technical Reports Server (NTRS)

    Bao, Xiaoqi; Badescu, Mircea; Bar-Cohen, Yoseph

    2015-01-01

    The potential to return Martian samples to Earth for extensive analysis is in great interest of the planetary science community. It is important to make sure the mission would securely contain any microbes that may possibly exist on Mars so that they would not be able to cause any adverse effects on Earth's environment. A brazing sealing and sterilizing technique has been proposed to break the Mars-to-Earth contamination chain. Thermal analysis of the brazing process was conducted for several conceptual designs that apply the technique. Control of the increase of the temperature of the Martian samples is a challenge. The temperature profiles of the Martian samples being sealed in the container were predicted by finite element thermal models. The results show that the sealing and sterilization process can be controlled such that the samples' temperature is maintained below the potentially required level, and that the brazing technique is a feasible approach to break the contamination chain.

  19. Sampling and Data Analysis for Environmental Microbiology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murray, Christopher J.

    2001-06-01

    A brief review of the literature indicates the importance of statistical analysis in applied and environmental microbiology. Sampling designs are particularly important for successful studies, and it is highly recommended that researchers review their sampling design before heading to the laboratory or the field. Most statisticians have numerous stories of scientists who approached them after their study was complete only to have to tell them that the data they gathered could not be used to test the hypothesis they wanted to address. Once the data are gathered, a large and complex body of statistical techniques are available for analysis ofmore » the data. Those methods include both numerical and graphical techniques for exploratory characterization of the data. Hypothesis testing and analysis of variance (ANOVA) are techniques that can be used to compare the mean and variance of two or more groups of samples. Regression can be used to examine the relationships between sets of variables and is often used to examine the dependence of microbiological populations on microbiological parameters. Multivariate statistics provides several methods that can be used for interpretation of datasets with a large number of variables and to partition samples into similar groups, a task that is very common in taxonomy, but also has applications in other fields of microbiology. Geostatistics and other techniques have been used to examine the spatial distribution of microorganisms. The objectives of this chapter are to provide a brief survey of some of the statistical techniques that can be used for sample design and data analysis of microbiological data in environmental studies, and to provide some examples of their use from the literature.« less

  20. Comparison of conventional PCR, quantitative PCR, bacteriological culture and the Warthin Starry technique to detect Leptospira spp. in kidney and liver samples from naturally infected sheep from Brazil.

    PubMed

    Fornazari, Felipe; da Silva, Rodrigo Costa; Richini-Pereira, Virginia Bodelão; Beserra, Hugo Enrique Orsini; Luvizotto, Maria Cecília Rui; Langoni, Helio

    2012-09-01

    Leptospirosis is an infectious disease of worldwide importance. The development of diagnostic techniques allows sick animals to be identified, reservoirs to be eliminated and the disease prevented and controlled. The present study aimed to compare different techniques for diagnosing leptospirosis in sheep. Samples of kidney, liver and blood were collected from 465 animals that originated from a slaughterhouse. The sera were analyzed by the Microscopic Agglutination Test (MAT), and kidney and liver samples of seropositive animals were analyzed using four techniques: bacteriological culture, the Warthin Starry (WS) technique, conventional PCR (cPCR), and quantitative PCR (qPCR). With the MAT, 21 animals were positive (4.5%) to serovars Hardjo (n=12), Hebdomadis (n=5), Sentot (n=2), Wolfii (n=1) and Shermani (n=1). Titers were 100 (n=10), 200 (n=2), 400 (n=6) and 1600 (n=3). No animal was positive by bacteriological culture; four animals were positive by the WS technique in kidney samples; six animals were positive by cPCR in kidney samples; and 11 animals were positive by qPCR, eight of which in kidney samples and three in liver. The bacterial quantification revealed a median of 4.3 bacteria/μL in liver samples and 36.6 bacteria/μL in kidney samples. qPCR presented the highest sensitivity among the techniques, followed by cPCR, the WS technique and bacteriological culture. These results indicate that sheep can carry leptospires of the Sejroe serogroup, and demonstrate the efficiency of quantitative PCR to detect Leptospira spp. in tissue samples. Published by Elsevier B.V.

  1. [Wound microbial sampling methods in surgical practice, imprint techniques].

    PubMed

    Chovanec, Z; Veverková, L; Votava, M; Svoboda, J; Peštál, A; Doležel, J; Jedlička, V; Veselý, M; Wechsler, J; Čapov, I

    2012-12-01

    The wound is a damage of tissue. The process of healing is influenced by many systemic and local factors. The most crucial and the most discussed local factor of wound healing is infection. Surgical site infection in the wound is caused by micro-organisms. This information is known for many years, however the conditions leading to an infection occurrence have not been sufficiently described yet. Correct sampling technique, correct storage, transportation, evaluation, and valid interpretation of these data are very important in clinical practice. There are many methods for microbiological sampling, but the best one has not been yet identified and validated. We aim to discuss the problem with the focus on the imprint technique.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Streza, M.; Dadarlat, D.; Strzałkowski, K.

    An accurate determination of thermophysical properties such as thermal diffusivity, thermal effusivity and thermal conductivity is extremely important for characterization and quality assurance of semiconductors. Thermal diffusivity and effusivity of some binary semiconductors have been investigated. Two experimental techniques were used: a contact technique (PPE calorimetry) and a non contact technique (lock-in thermography). When working with PPE, in the back (BPPE) configuration and in the thermally thick regim of the pyroelectric sensor, we can get the thermal diffusivity of the sample by performing a scanning of the excitation frequency of radiation. Thermal effusivity is obtained in front configuration (sensor directlymore » irradiated and sample in back position) by performing a thickness scan of a coupling fluid. By using the lock-in thermography technique, the thermal diffusivity of the sample is obtained from the phase image. The results obtained by the two techniques are in good agreement. Nevertheless, for the determination of thermal diffusivity, lock-in thermography is preferred.« less

  3. Nose biopsy: a comparison between two sampling techniques.

    PubMed

    Segal, Nili; Osyntsov, Lidia; Olchowski, Judith; Kordeluk, Sofia; Plakht, Ygal

    2016-06-01

    Pre operative biopsy is important in obtaining preliminary information that may help in tailoring the optimal treatment. The aim of this study was to compare two sampling techniques of obtaining nasal biopsy-nasal forceps and nasal scissors in terms of pathological results. Biopsies of nasal lesions were taken from patients undergoing nasal surgery by two techniques- with nasal forceps and with nasal scissors. Each sample was examined by a senior pathologist that was blinded to the sampling method. A grading system was used to rate the crush artifact in every sample (none, mild, moderate, severe). A comparison was made between the severity of the crush artifact and the pathological results of the two techniques. One hundred and forty-four samples were taken from 46 patients. Thirty-one were males and the mean age was 49.6 years. Samples taken by forceps had significantly higher grades of crush artifacts compared to those taken by scissors. The degree of crush artifacts had a significant influence on the accuracy of the pre operative biopsy. Forceps cause significant amount of crush artifacts compared to scissors. The degree of crush artifact in the tissue sample influences the accuracy of the biopsy.

  4. Analytical techniques for identification and study of organic matter in returned lunar samples

    NASA Technical Reports Server (NTRS)

    Burlingame, A. L.

    1974-01-01

    The results of geochemical research are reviewed. Emphasis is placed on the contribution of mass spectrometric data to the solution of specific structural problems. Information on the mass spectrometric behavior of compounds of geochemical interest is reviewed and currently available techniques of particular importance to geochemistry, such as gas chromatograph-mass spectrometer coupling, modern sample introduction methods, and computer application in high resolution mass spectrometry, receive particular attention.

  5. Attempts to develop a new nuclear measurement technique of β-glucuronidase levels in biological samples

    NASA Astrophysics Data System (ADS)

    Ünak, T.; Avcibasi, U.; Yildirim, Y.; Çetinkaya, B.

    2003-01-01

    β-Glucuronidase is one of the most important hydrolytic enzymes in living systems and plays an essential role in the detoxification pathway of toxic materials incorporated into the metabolism. Some organs, especially liver and some tumour tissues, have high level of β-glucuronidase activity. As a result the enzymatic activity of some kind of tumour cells, the radiolabelled glucuronide conjugates of cytotoxic, as well as radiotoxic compounds have potentially very valuable diagnostic and therapeutic applications in cancer research. For this reason, a sensitive measurement of β-glucuronidase levels in normal and tumour tissues is a very important step for these kinds of applications. According to the classical measurement method of β-glucuronidase activity, in general, the quantity of phenolphthalein liberated from its glucuronide conjugate, i.e. phenolphthalein-glucuronide, by β-glucuronidase has been measured by use of the spectrophotometric technique. The lower detection limit of phenolphthalein by the spectrophotometric technique is about 1-3 μg. This means that the β-glucuronidase levels could not be detected in biological samples having lower levels of β-glucuronidase activity and therefore the applications of the spectrophotometric technique in cancer research are very seriously limited. Starting from this consideration, we recently attempted to develop a new nuclear technique to measure much lower concentrations of β-glucuronidase in biological samples. To improve the detection limit, phenolphthalein-glucuronide and also phenyl-N-glucuronide were radioiodinated with 131I and their radioactivity was measured by use of the counting technique. Therefore, the quantity of phenolphthalein or aniline radioiodinated with 131I and liberated by the deglucuronidation reactivity of β-glucuronidase was used in an attempt to measure levels lower than the spectrophotometric measurement technique. The results obtained clearly verified that 0.01 pg level of phenolphthalein or aniline could easily be detected at least 106 times more sensitively. The preliminary results obtained on some biological samples have shown that β-glucuronidase levels could reasonably be measured by use of the nuclear technique. In addition, our results also indicate the potential application of the radiolabelling technique to measure very low β-glucuronidase levels in different biological samples in cancer research and other related fields. The objective of our study is to demonstrate the potential application of the nuclear measurement technique in different biological samples.

  6. Joint use of over- and under-sampling techniques and cross-validation for the development and assessment of prediction models.

    PubMed

    Blagus, Rok; Lusa, Lara

    2015-11-04

    Prediction models are used in clinical research to develop rules that can be used to accurately predict the outcome of the patients based on some of their characteristics. They represent a valuable tool in the decision making process of clinicians and health policy makers, as they enable them to estimate the probability that patients have or will develop a disease, will respond to a treatment, or that their disease will recur. The interest devoted to prediction models in the biomedical community has been growing in the last few years. Often the data used to develop the prediction models are class-imbalanced as only few patients experience the event (and therefore belong to minority class). Prediction models developed using class-imbalanced data tend to achieve sub-optimal predictive accuracy in the minority class. This problem can be diminished by using sampling techniques aimed at balancing the class distribution. These techniques include under- and oversampling, where a fraction of the majority class samples are retained in the analysis or new samples from the minority class are generated. The correct assessment of how the prediction model is likely to perform on independent data is of crucial importance; in the absence of an independent data set, cross-validation is normally used. While the importance of correct cross-validation is well documented in the biomedical literature, the challenges posed by the joint use of sampling techniques and cross-validation have not been addressed. We show that care must be taken to ensure that cross-validation is performed correctly on sampled data, and that the risk of overestimating the predictive accuracy is greater when oversampling techniques are used. Examples based on the re-analysis of real datasets and simulation studies are provided. We identify some results from the biomedical literature where the incorrect cross-validation was performed, where we expect that the performance of oversampling techniques was heavily overestimated.

  7. Isotopic signatures: An important tool in today`s world

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rokop, D.J.; Efurd, D.W.; Benjamin, T.M.

    1995-12-01

    High-sensitivity/high-accuracy actinide measurement techniques developed to support weapons diagnostic capabilities at the Los Alamos National Laboratory are now being used for environmental monitoring. The measurement techniques used are Thermal Ionization Mass Spectrometry (TIMS), Alpha Spectrometry(AS), and High Resolution Gamma Spectrometry(HRGS). These techniques are used to address a wide variety of actinide inventory issues: Environmental surveillance, site characterizations, food chain member determination, sedimentary records of activities, and treaty compliance concerns. As little as 10 femtograms of plutonium can be detected in samples and isotopic signatures determined on samples containing sub-100 femtogram amounts. Uranium, present in all environmental samples, can generally yieldmore » isotopic signatures of anthropogenic origin when present at the 40 picogam/gram level. Solid samples (soils, sediments, fauna, and tissue) can range from a few particles to several kilograms in size. Water samples can range from a few milliliters to as much as 200 liters.« less

  8. Integrating diffusion maps with umbrella sampling: Application to alanine dipeptide

    NASA Astrophysics Data System (ADS)

    Ferguson, Andrew L.; Panagiotopoulos, Athanassios Z.; Debenedetti, Pablo G.; Kevrekidis, Ioannis G.

    2011-04-01

    Nonlinear dimensionality reduction techniques can be applied to molecular simulation trajectories to systematically extract a small number of variables with which to parametrize the important dynamical motions of the system. For molecular systems exhibiting free energy barriers exceeding a few kBT, inadequate sampling of the barrier regions between stable or metastable basins can lead to a poor global characterization of the free energy landscape. We present an adaptation of a nonlinear dimensionality reduction technique known as the diffusion map that extends its applicability to biased umbrella sampling simulation trajectories in which restraining potentials are employed to drive the system into high free energy regions and improve sampling of phase space. We then propose a bootstrapped approach to iteratively discover good low-dimensional parametrizations by interleaving successive rounds of umbrella sampling and diffusion mapping, and we illustrate the technique through a study of alanine dipeptide in explicit solvent.

  9. Helminth Infections by Coprological Examination in Sheep-Dogs and Their Zoonotic Importance.

    PubMed

    Öge, Hatice; Öge, Semih; Özbakış, Gökben; Gürcan, I Safa

    2017-03-01

    This study was conducted to determine the prevalence of gastrointestinal helminths and diagnose the species of important zoonotic helminths in sheep dogs. Firstly, fecal samples were macroscopically examined; subsequently, formalin-ethyl acetate sedimentation and ZnSO4 centrifugal floatation techniques were applied for the examination of helminth eggs. PCR technique was utilized to determine the species of E. granulosus and T. canis in dogs found positive for Taenia spp. and Toxocara spp. Helminth infection was detected in 35.26% of sheep dogs. Taenia spp. was the most common helminth (12.05%), followed by Toxocara spp. (9.38%), Toxascaris leonina (6.25%), and Trichuris spp. (4.2%). The positive results in the E. granulosus and T. canis-specific PCR-based molecular tests were obtained in 14 of the Taenia egg-positive samples and in 5 of the Toxocara egg-positive samples from dogs. This study has suggested that coprophagy and feed raw offal and meat to dogs may be responsible for finding atypical helminth eggs in fecal samples from dogs in the absence of an actual infection. To make the diagnosis of their owned parasites of dogs, E. granulosus and T. canis which have zoonotic importance, feces must be examined by both conventional and copro-PCR techniques. In addition to dogs' feeding habits, other related factors must be taken into account in the epidemiology of helminth infection; thus, precaution and control measures will be more reliable.

  10. Survey of techniques used to preserve biological materials

    NASA Technical Reports Server (NTRS)

    Feinler, E. J.; Hubbard, R. W.

    1972-01-01

    The techniques used to preserve biological materials are documented and summarized. The report is presented in a handbook format that categorizes the most important preservation techniques available, and includes a representative sampling of the thousands of applications of these techniques to biological materials and organisms. Details of the information coverage and method of approach are outlined. Data are given in tabular form, and an index and extensive bibliography are included.

  11. Development of porous titanium for biomedical applications: A comparison between loose sintering and space-holder techniques.

    PubMed

    Torres, Yadir; Lascano, Sheila; Bris, Jorge; Pavón, Juan; Rodriguez, José A

    2014-04-01

    One of the most important concerns in long-term prostheses is bone resorption as a result of the stress shielding due to stiffness mismatch between bone and implant. The aim of this study was to obtain porous titanium with stiffness values similar to that exhibited by cortical bone. Porous samples of commercial pure titanium grade-4 were obtained by following both loose-sintering processing and space-holder technique with NaCl between 40 and 70% in volume fraction. Both mechanical properties and porosity morphology were assessed. Young's modulus was measured using uniaxial compression testing, as well as ultrasound methodology. Complete characterization and mechanical testing results allowed us to determine some important findings: (i) optimal parameters for both processing routes; (ii) better mechanical response was obtained by using space-holder technique; (iii) pore geometry of loose sintering samples becomes more regular with increasing sintering temperature; in the case of the space-holder technique that trend was observed for decreasing volume fraction; (iv) most reliable Young's modulus measurements were achieved by ultrasound technique. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. FT-Raman study of dehydrogenation polymer (DHP) lignins

    Treesearch

    Umesh P. Agarwal; Noritsugu Terashima

    2003-01-01

    Compared to conventional Raman spectroscopy where samples are excited using visible light lasers, 1064 nm-excited FT-Raman technique has the single most important advantage that the sample-fluorescence is significantly suppressed for samples that are strongly fluorescent. DHPs are difficult to analyze in conventional Raman because small amounts of chromophores present...

  13. A LITERATURE REVIEW OF WIPE SAMPLING METHODS FOR CHEMICAL WARFARE AGENTS AND TOXIC INDUSTRIAL CHEMICALS

    EPA Science Inventory

    Wipe sampling is an important technique for the estimation of contaminant deposition in buildings, homes, or outdoor surfaces as a source of possible human exposure. Numerous

    methods of wipe sampling exist, and each method has its own specification for the type of wipe, we...

  14. The importance of sound methodology in environmental DNA sampling

    Treesearch

    T. M. Wilcox; K. J. Carim; M. K. Young; K. S. McKelvey; T. W. Franklin; M. K. Schwartz

    2018-01-01

    Environmental DNA (eDNA) sampling - which enables inferences of species’ presence from genetic material in the environment - is a powerful tool for sampling rare fishes. Numerous studies have demonstrated that eDNA sampling generally provides greater probabilities of detection than traditional techniques (e.g., Thomsen et al. 2012; McKelvey et al. 2016; Valentini et al...

  15. A comprehensive evaluation of various sensitivity analysis methods: A case study with a hydrological model

    DOE PAGES

    Gan, Yanjun; Duan, Qingyun; Gong, Wei; ...

    2014-01-01

    Sensitivity analysis (SA) is a commonly used approach for identifying important parameters that dominate model behaviors. We use a newly developed software package, a Problem Solving environment for Uncertainty Analysis and Design Exploration (PSUADE), to evaluate the effectiveness and efficiency of ten widely used SA methods, including seven qualitative and three quantitative ones. All SA methods are tested using a variety of sampling techniques to screen out the most sensitive (i.e., important) parameters from the insensitive ones. The Sacramento Soil Moisture Accounting (SAC-SMA) model, which has thirteen tunable parameters, is used for illustration. The South Branch Potomac River basin nearmore » Springfield, West Virginia in the U.S. is chosen as the study area. The key findings from this study are: (1) For qualitative SA methods, Correlation Analysis (CA), Regression Analysis (RA), and Gaussian Process (GP) screening methods are shown to be not effective in this example. Morris One-At-a-Time (MOAT) screening is the most efficient, needing only 280 samples to identify the most important parameters, but it is the least robust method. Multivariate Adaptive Regression Splines (MARS), Delta Test (DT) and Sum-Of-Trees (SOT) screening methods need about 400–600 samples for the same purpose. Monte Carlo (MC), Orthogonal Array (OA) and Orthogonal Array based Latin Hypercube (OALH) are appropriate sampling techniques for them; (2) For quantitative SA methods, at least 2777 samples are needed for Fourier Amplitude Sensitivity Test (FAST) to identity parameter main effect. McKay method needs about 360 samples to evaluate the main effect, more than 1000 samples to assess the two-way interaction effect. OALH and LPτ (LPTAU) sampling techniques are more appropriate for McKay method. For the Sobol' method, the minimum samples needed are 1050 to compute the first-order and total sensitivity indices correctly. These comparisons show that qualitative SA methods are more efficient but less accurate and robust than quantitative ones.« less

  16. Cryopreservation of human sperm: efficacy and use of a new nitrogen-free controlled rate freezer versus liquid nitrogen vapour freezing.

    PubMed

    Creemers, E; Nijs, M; Vanheusden, E; Ombelet, W

    2011-12-01

    Preservation of spermatozoa is an important aspect of assisted reproductive medicine. The aim of this study was to investigate the efficacy and use of a recently developed liquid nitrogen and cryogen-free controlled rate freezer and this compared with the classical liquid nitrogen vapour freezing method for the cryopreservation of human spermatozoa. Ten patients entering the IVF programme donated semen samples for the study. Samples were analysed according to the World Health Organization guidelines. No significant difference in total sperm motility after freeze-thawing between the new technique and classical technique was demonstrated. The advantage of the new freezing technique is that it uses no liquid nitrogen during the freezing process, hence being safer to use and clean room compatible. Investment costs are higher for the apparatus but running costs are only 1% in comparison with classical liquid nitrogen freezing. In conclusion, post-thaw motility of samples frozen with the classical liquid nitrogen vapour technique was comparable with samples frozen with the new nitrogen-free freezing technique. This latter technique can thus be a very useful asset to the sperm cryopreservation laboratory. © 2011 Blackwell Verlag GmbH.

  17. Applications of synchrotron μ-XRF to study the distribution of biologically important elements in different environmental matrices: a review.

    PubMed

    Majumdar, Sanghamitra; Peralta-Videa, Jose R; Castillo-Michel, Hiram; Hong, Jie; Rico, Cyren M; Gardea-Torresdey, Jorge L

    2012-11-28

    Environmental matrices including soils, sediments, and living organisms are reservoirs of several essential as well as non-essential elements. Accurate qualitative and quantitative information on the distribution and interaction of biologically significant elements is vital to understand the role of these elements in environmental and biological samples. Synchrotron micro-X-ray fluorescence (μ-SXRF) allows in situ mapping of biologically important elements at nanometer to sub-micrometer scale with high sensitivity, negligible sample damage and enable tuning of the incident energy as desired. Beamlines in the synchrotron facilities are rapidly increasing their analytical versatility in terms of focusing optics, detector technologies, incident energy, and sample environment. Although extremely competitive, it is now feasible to find stations offering complimentary techniques like micro-X-ray diffraction (μ-XRD) and micro-X-ray absorption spectroscopy (μ-XAS) that will allow a more complete characterization of complex matrices. This review includes the most recent literature on the emerging applications and challenges of μ-SXRF in studying the distribution of biologically important elements and manufactured nanoparticles in soils, sediments, plants, and microbes. The advantages of using μ-SXRF and complimentary techniques in contrast to conventional techniques used for the respective studies are discussed. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Heating and thermal control of brazing technique to break contamination path for potential Mars sample return

    NASA Astrophysics Data System (ADS)

    Bao, Xiaoqi; Badescu, Mircea; Sherrit, Stewart; Bar-Cohen, Yoseph; Campos, Sergio

    2017-04-01

    The potential return of Mars sample material is of great interest to the planetary science community, as it would enable extensive analysis of samples with highly sensitive laboratory instruments. It is important to make sure such a mission concept would not bring any living microbes, which may possibly exist on Mars, back to Earth's environment. In order to ensure the isolation of Mars microbes from Earth's Atmosphere, a brazing sealing and sterilizing technique was proposed to break the Mars-to-Earth contamination path. Effectively, heating the brazing zone in high vacuum space and controlling the sample temperature for integrity are key challenges to the implementation of this technique. The break-thechain procedures for container configurations, which are being considered, were simulated by multi-physics finite element models. Different heating methods including induction and resistive/radiation were evaluated. The temperature profiles of Martian samples in a proposed container structure were predicted. The results show that the sealing and sterilizing process can be controlled such that the samples temperature is maintained below the level that may cause damage, and that the brazing technique is a feasible approach to breaking the contamination path.

  19. A Visual Evaluation Study of Graph Sampling Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Fangyan; Zhang, Song; Wong, Pak C.

    2017-01-29

    We evaluate a dozen prevailing graph-sampling techniques with an ultimate goal to better visualize and understand big and complex graphs that exhibit different properties and structures. The evaluation uses eight benchmark datasets with four different graph types collected from Stanford Network Analysis Platform and NetworkX to give a comprehensive comparison of various types of graphs. The study provides a practical guideline for visualizing big graphs of different sizes and structures. The paper discusses results and important observations from the study.

  20. Sampling Mars: Analytical requirements and work to do in advance

    NASA Technical Reports Server (NTRS)

    Koeberl, Christian

    1988-01-01

    Sending a mission to Mars to collect samples and return them to the Earth for analysis is without doubt one of the most exciting and important tasks for planetary science in the near future. Many scientifically important questions are associated with the knowledge of the composition and structure of Martian samples. Amongst the most exciting questions is the clarification of the SNC problem- to prove or disprove a possible Martian origin of these meteorites. Since SNC meteorites have been used to infer the chemistry of the planet Mars, and its evolution (including the accretion history), it would be important to know if the whole story is true. But before addressing possible scientific results, we have to deal with the analytical requirements, and with possible pre-return work. It is unlikely to expect that a possible Mars sample return mission will bring back anything close to the amount returned by the Apollo missions. It will be more like the amount returned by the Luna missions, or at least in that order of magnitude. This requires very careful sample selection, and very precise analytical techniques. These techniques should be able to use minimal sample sizes and on the other hand optimize the scientific output. The possibility to work with extremely small samples should not obstruct another problem: possible sampling errors. As we know from terrestrial geochemical studies, sampling procedures are quite complicated and elaborate to ensure avoiding sampling errors. The significance of analyzing a milligram or submilligram sized sample and putting that in relationship with the genesis of whole planetary crusts has to be viewed with care. This leaves a dilemma on one hand, to minimize the sample size as far as possible in order to have the possibility of returning as many different samples as possible, and on the other hand to take a sample large enough to be representative. Whole rock samples are very useful, but should not exceed the 20 to 50 g range, except in cases of extreme inhomogeneity, because for larger samples the information tends to become redundant. Soil samples should be in the 2 to 10 g range, permitting the splitting of the returned samples for studies in different laboratories with variety of techniques.

  1. Analytical determination of selenium in medical samples, staple food and dietary supplements by means of total reflection X-ray fluorescence spectroscopy

    NASA Astrophysics Data System (ADS)

    Stosnach, Hagen

    2010-09-01

    Selenium is essential for many aspects of human health and, thus, the object of intensive medical research. This demands the use of analytical techniques capable of analysing selenium at low concentrations with high accuracy in widespread matrices and sometimes smallest sample amounts. In connection with the increasing importance of selenium, there is a need for rapid and simple on-site (or near-to-site) selenium analysis in food basics like wheat at processing and production sites, as well as for the analysis of this element in dietary supplements. Common analytical techniques like electrothermal atomic absorption spectroscopy (ETAAS) and inductively-coupled plasma mass spectrometry (ICP-MS) are capable of analysing selenium in medical samples with detection limits in the range from 0.02 to 0.7 μg/l. Since in many cases less complicated and expensive analytical techniques are required, TXRF has been tested regarding its suitability for selenium analysis in different medical, food basics and dietary supplement samples applying most simple sample preparation techniques. The reported results indicate that the accurate analysis of selenium in all sample types is possible. The detection limits of TXRF are in the range from 7 to 12 μg/l for medical samples and 0.1 to 0.2 mg/kg for food basics and dietary supplements. Although this sensitivity is low compared to established techniques, it is sufficient for the physiological concentrations of selenium in the investigated samples.

  2. Soil and Water – What is Detectable through Microbiological Sample Preparation Techniques

    EPA Science Inventory

    The concerns of a potential terrorist’s use of biological agents in soil and ground water are articulated by comparisons to major illnesses in this Country involving contaminated drinking water sources. Objectives are focused on the importance of sample preparation in the rapid, ...

  3. Finnish cytotechnologists' views on the competencies of newly graduated biomedical scientists in clinical cytology.

    PubMed

    Liikanen, E

    2018-02-01

    This study asked 40 cytotechnologists for their views on the competencies of newly graduated biomedical scientists in clinical cytology during the national conference of the Finnish Association of Cytotechnologists in November 2015. The questionnaire mainly consisted of statements that were scored on a five-point Likert-scale, where 1 was not important and 5 was very important. It covered five sections of clinical cytology: sampling and techniques, gynaecological screening, non-gynaecological screening, safety and quality management, and miscellaneous. Of the 40 delegates approached to complete the questionnaire, 37 (92.5%) agreed. Respondents felt that important sampling and technique competencies were specimen fixation, with a mean score of 4.9 out of 5.0, types of specimens (4.7), Papanicolaou smear collection (4.7), Papanicolaou smear request information (4.7) and evaluation of specimen sufficiency (4.6). Less important competencies were examining FNAs (2.0) and nasopharyngeal specimens (2.2). The respondents had many expectations about how education in cytology could be developed, for example more theoretical lessons, more practice in microscope use, and consistent criteria for training and cooperation between cytology laboratories and universities of applied sciences. The cytotechnologists who took part in our survey expected newly graduated biomedical scientists to have basic competencies in cytology. These were sampling and techniques, laboratory safety and quality management, specimen adequacy and identifying normal cells taken during gynaecological screening. They were also keen to develop education in cytology. © 2017 John Wiley & Sons Ltd.

  4. Thermal Image of Coffee-Seed Germ Obtained by Photoacoustic Microscopy

    NASA Astrophysics Data System (ADS)

    Domínguez-Pacheco, A.; Hernández Aguilar, C.; Cruz-Orea, Alfredo; Isaac Alemán, E.; Martínez Ortiz, E.

    2013-09-01

    Photoacoustic microscopy (PAM) has been shown to be a suitable technique to obtain thermal images of a wide variety of samples from semiconductors to biological material. In PAM, the incidence of a modulated laser beam on a sample within a photoacoustic (PA) cell, hermetically sealed, produces a PA signal which depends on the thermal and optical properties of the studied sample. By making a sweep of the modulated laser beam on the sample surface, it is possible to obtain the PA signal as a function of their x- y coordinates, and from this signal, it is possible to reconstruct thermal images of the sample. In this study, thermal images of a coffee-seed germ were obtained, with a difference of 12 h between them, by using the PAM technique. Thermal differences observed between images give information which reflects degradation due to the fact that germ cells undergo changes as a function of time. The thermal images obtained by the PAM technique could be applied to biological materials that have a complex constitution (not homogeneous) in their structures, and thermal differences can be observed. PAM is a non-destructive technique, which is an important feature for this type of study. Other applications of this technique can be performed in the agricultural and biotechnological areas.

  5. Geochemical Exploration Techniques Applicable in the Search for Copper Deposits

    USGS Publications Warehouse

    Chaffee, Maurice A.

    1975-01-01

    Geochemical exploration is an important part of copper-resource evaluation. A large number of geochemical exploration techniques, both proved and untried, are available to the geochemist to use in the search for new copper deposits. Analyses of whole-rock samples have been used in both regional and local geochemical exploration surveys in the search for copper. Analyses of mineral separates, such as biotite, magnetite, and sulfides, have also been used. Analyses of soil samples are widely used in geochemical exploration, especially for localized surveys. It is important to distinguish between residual and transported soil types. Orientation studies should always be conducted prior to a geochemical investigation in a given area in order to determine the best soil horizon and the best size of soil material for sampling in that area. Silty frost boils, caliche, and desert varnish are specialized types of soil samples that might be useful sampling media. Soil gas is a new and potentially valuable geochemical sampling medium, especially in exploring for buried mineral deposits in arid regions. Gaseous products in samples of soil may be related to base-metal deposits and include mercury vapor, sulfur dioxide, hydrogen sulfide, carbon oxysulfide, carbon dioxide, hydrogen, oxygen, nitrogen, the noble gases, the halogens, and many hydrocarbon compounds. Transported materials that have been used in geochemical sampling programs include glacial float boulders, glacial till, esker gravels, stream sediments, stream-sediment concentrates, and lake sediments. Stream-sediment sampling is probably the most widely used and most successful geochemical exploration technique. Hydrogeochemical exploration programs have utilized hot- and cold-spring waters and their precipitates as well as waters from lakes, streams, and wells. Organic gel found in lakes and at stream mouths is an unproved sampling medium. Suspended material and dissolved gases in any type of water may also be useful media. Samples of ice and snow have been used for limited geochemical surveys. Both geobotanical and biogeochemical surveys have been successful in locating copper deposits in many parts of the world. Micro-organisms, including bacteria and algae, are other unproved media that should be studied. Animals can be used in geochemical-prospecting programs. Dogs have been used quite successfully to sniff out hidden and exposed sulfide minerals. Tennite mounds are commonly composed of subsurface material, but have not as yet proved to be useful in locating buried mineral deposits. Animal tissue and waste products are essentially unproved but potentially valuable sampling media. Knowledge of the location of areas where trace-element-associated diseases in animals and man are endemic as well as a better understanding of these diseases, may aid in identifying regions that are enriched in or depleted of various elements, including copper. Results of analyses of gases in the atmosphere are proving valuable in mineral-exploration surveys. Studies involving metallic compounds exhaled by plants into the atmosphere, and of particulate matter suspended in the atmosphere are reviewed these methods may become important in the future. Remote-sensing techniques are useful for making indirect measurements of geochemical responses. Two techniques applicable to geochemical exploration are neutron-activation analysis and gamma-ray spectrometry. Aerial photography is especially useful in vegetation surveys. Radar imagery is an unproved but potentially valuable method for use in studies of vegetation in perpetually clouded regions. With the advent of modern computers, many new techniques, such as correlation analysis, regression analysis, discriminant analysis, factor analysis, cluster analysis, trend-surface analysis, and moving-average analysis can be applied to geochemical data sets. Selective use of these techniques can provide new insights into the interpretatio

  6. Systematic comparison of static and dynamic headspace sampling techniques for gas chromatography.

    PubMed

    Kremser, Andreas; Jochmann, Maik A; Schmidt, Torsten C

    2016-09-01

    Six automated, headspace-based sample preparation techniques were used to extract volatile analytes from water with the goal of establishing a systematic comparison between commonly available instrumental alternatives. To that end, these six techniques were used in conjunction with the same gas chromatography instrument for analysis of a common set of volatile organic carbon (VOC) analytes. The methods were thereby divided into three classes: static sampling (by syringe or loop), static enrichment (SPME and PAL SPME Arrow), and dynamic enrichment (ITEX and trap sampling). For PAL SPME Arrow, different sorption phase materials were also included in the evaluation. To enable an effective comparison, method detection limits (MDLs), relative standard deviations (RSDs), and extraction yields were determined and are discussed for all techniques. While static sampling techniques exhibited sufficient extraction yields (approx. 10-20 %) to be reliably used down to approx. 100 ng L(-1), enrichment techniques displayed extraction yields of up to 80 %, resulting in MDLs down to the picogram per liter range. RSDs for all techniques were below 27 %. The choice on one of the different instrumental modes of operation (aforementioned classes) was thereby the most influential parameter in terms of extraction yields and MDLs. Individual methods inside each class showed smaller deviations, and the least influences were observed when evaluating different sorption phase materials for the individual enrichment techniques. The option of selecting specialized sorption phase materials may, however, be more important when analyzing analytes with different properties such as high polarity or the capability of specific molecular interactions. Graphical Abstract PAL SPME Arrow during the extraction of volatile analytes from the headspace of an aqueous sample.

  7. Study of atmospheric aerosols by IBA techniques: The LABEC experience

    NASA Astrophysics Data System (ADS)

    Lucarelli, F.; Calzolai, G.; Chiari, M.; Nava, S.; Carraresi, L.

    2018-02-01

    At the 3 MV Tandetron accelerator of the LABEC laboratory of INFN (Florence, Italy) an external beam facility is fully dedicated to PIXE-PIGE measurements of the elemental composition of atmospheric aerosols. All the elements with Z > 10 are simultaneously detected by PIXE typically in one minute. This setup allows us an easy automatic positioning, changing and scanning of samples collected by different kinds of devices: long series of daily PM (Particulate Matter) samples can be analysed in short times, as well as size-segregated and high time-resolution aerosol samples. Thanks to the capability of detecting all the crustal elements, PIXE-PIGE analyses are unrivalled in the study of mineral dust: consequently, they are very effective in the study of natural aerosols, like, for example, Saharan dust intrusions. Among the detectable elements there are also important markers of anthropogenic sources, which allow effective source apportionment studies in polluted urban environments using a multivariate method like Positive Matrix Factorization (PMF). Examples regarding recent monitoring campaigns, performed in urban and remote areas, both daily and with high time resolution (hourly samples), as well as with size selection, are presented. The importance of the combined use of the Particle Induced Gamma Ray emission technique (PIGE) and of other complementary (non-nuclear) techniques is highlighted.

  8. A contribution to reduce sampling variability in the evaluation of deoxynivalenol contamination of organic wheat grain.

    PubMed

    Hallier, Arnaud; Celette, Florian; Coutarel, Julie; David, Christophe

    2013-01-01

    Fusarium head blight caused by different varieties of Fusarium species is one of the major serious worldwide diseases found in wheat production. It is therefore important to be able to quantify the deoxynivalenol concentration in wheat. Unfortunately, in mycotoxin quantification, due to the uneven distribution of mycotoxins within the initial lot, it is difficult, or even impossible, to obtain a truly representative analytical sample. In previous work we showed that the sampling step most responsible for variability was grain sampling. In this paper, it is more particularly the step scaling down from a laboratory sample of some kilograms to an analytical sample of a few grams that is investigated. The naturally contaminated wheat lot was obtained from an organic field located in the southeast of France (Rhône-Alpes) from the year 2008-2009 cropping season. The deoxynivalenol level was found to be 50.6 ± 2.3 ng g⁻¹. Deoxynivalenol was extracted with a acetonitrile-water mix and quantified by gas chromatography-electron capture detection (GC-ECD). Three different grain sampling techniques were tested to obtain analytical samples: a technique based on manually homogenisation and division, a second technique based on the use of a rotating shaker and a third on the use of compressed air. Both the rotating shaker and the compressed air techniques enabled a homogeneous laboratory sample to be obtained, from which representative analytical samples could be taken. Moreover, the techniques did away with many repetitions and grinding. This study, therefore, contributes to sampling variability reduction in the evaluation of deoxynivalenol contamination of organic wheat grain, and then, at a reasonable cost.

  9. A Size Exclusion Chromatography Laboratory with Unknowns for Introductory Students

    ERIC Educational Resources Information Center

    McIntee, Edward J.; Graham, Kate J.; Colosky, Edward C.; Jakubowski, Henry V.

    2015-01-01

    Size exclusion chromatography is an important technique in the separation of biological and polymeric samples by molecular weight. While a number of laboratory experiments have been published that use this technique for the purification of large molecules, this is the first report of an experiment that focuses on purifying an unknown small…

  10. Applying a low energy HPGe detector gamma ray spectrometric technique for the evaluation of Pu/Am ratio in biological samples.

    PubMed

    Singh, I S; Mishra, Lokpati; Yadav, J R; Nadar, M Y; Rao, D D; Pradeepkumar, K S

    2015-10-01

    The estimation of Pu/(241)Am ratio in the biological samples is an important input for the assessment of internal dose received by the workers. The radiochemical separation of Pu isotopes and (241)Am in a sample followed by alpha spectrometry is a widely used technique for the determination of Pu/(241)Am ratio. However, this method is time consuming and many times quick estimation is required. In this work, Pu/(241)Am ratio in the biological sample was estimated with HPGe detector based measurements using gamma/X-rays emitted by these radionuclides. These results were compared with those obtained from alpha spectroscopy of sample after radiochemical analysis and found to be in good agreement. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. The Role of the Sampling Distribution in Understanding Statistical Inference

    ERIC Educational Resources Information Center

    Lipson, Kay

    2003-01-01

    Many statistics educators believe that few students develop the level of conceptual understanding essential for them to apply correctly the statistical techniques at their disposal and to interpret their outcomes appropriately. It is also commonly believed that the sampling distribution plays an important role in developing this understanding.…

  12. [Comparative GC analysis of essential oil in imported sandalwood].

    PubMed

    Wang, Z; Hong, X

    1991-01-01

    The GC-fingerprint spectra of essential oils in imported sandalwood are established by the new technique of GC-relative retention value fingerprint spectrum (GC-FPS). According to the GC-FPS of samples, their chromatographic peaks, overlap ratio of peaks and eight strong peaks are studied comparatively.

  13. A Procedure for Analyzing Classroom Dialogue.

    ERIC Educational Resources Information Center

    Clarke, John A.

    Classroom dialogue is an important influence on students' learning, making the structure and content of dialogue important research variables. An analysis of two sample classroom dialogues using the Thematic and Structural Analysis (TSA) Technique shows a positive correlation between the quality of dialogue structure and the level of student…

  14. Quantitative X-ray dark-field and phase tomography using single directional speckle scanning technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Hongchang, E-mail: hongchang.wang@diamond.ac.uk; Kashyap, Yogesh; Sawhney, Kawal

    2016-03-21

    X-ray dark-field contrast tomography can provide important supplementary information inside a sample to the conventional absorption tomography. Recently, the X-ray speckle based technique has been proposed to provide qualitative two-dimensional dark-field imaging with a simple experimental arrangement. In this letter, we deduce a relationship between the second moment of scattering angle distribution and cross-correlation degradation of speckle and establish a quantitative basis of X-ray dark-field tomography using single directional speckle scanning technique. In addition, the phase contrast images can be simultaneously retrieved permitting tomographic reconstruction, which yields enhanced contrast in weakly absorbing materials. Such complementary tomography technique can allow systematicmore » investigation of complex samples containing both soft and hard materials.« less

  15. 3D-Laser-Scanning Technique Applied to Bulk Density Measurements of Apollo Lunar Samples

    NASA Technical Reports Server (NTRS)

    Macke, R. J.; Kent, J. J.; Kiefer, W. S.; Britt, D. T.

    2015-01-01

    In order to better interpret gravimetric data from orbiters such as GRAIL and LRO to understand the subsurface composition and structure of the lunar crust, it is import to have a reliable database of the density and porosity of lunar materials. To this end, we have been surveying these physical properties in both lunar meteorites and Apollo lunar samples. To measure porosity, both grain density and bulk density are required. For bulk density, our group has historically utilized sub-mm bead immersion techniques extensively, though several factors have made this technique problematic for our work with Apollo samples. Samples allocated for measurement are often smaller than optimal for the technique, leading to large error bars. Also, for some samples we were required to use pure alumina beads instead of our usual glass beads. The alumina beads were subject to undesirable static effects, producing unreliable results. Other investigators have tested the use of 3d laser scanners on meteorites for measuring bulk volumes. Early work, though promising, was plagued with difficulties including poor response on dark or reflective surfaces, difficulty reproducing sharp edges, and large processing time for producing shape models. Due to progress in technology, however, laser scanners have improved considerably in recent years. We tested this technique on 27 lunar samples in the Apollo collection using a scanner at NASA Johnson Space Center. We found it to be reliable and more precise than beads, with the added benefit that it involves no direct contact with the sample, enabling the study of particularly friable samples for which bead immersion is not possible

  16. Efficient Stochastic Rendering of Static and Animated Volumes Using Visibility Sweeps.

    PubMed

    von Radziewsky, Philipp; Kroes, Thomas; Eisemann, Martin; Eisemann, Elmar

    2017-09-01

    Stochastically solving the rendering integral (particularly visibility) is the de-facto standard for physically-based light transport but it is computationally expensive, especially when displaying heterogeneous volumetric data. In this work, we present efficient techniques to speed-up the rendering process via a novel visibility-estimation method in concert with an unbiased importance sampling (involving environmental lighting and visibility inside the volume), filtering, and update techniques for both static and animated scenes. Our major contributions include a progressive estimate of partial occlusions based on a fast sweeping-plane algorithm. These occlusions are stored in an octahedral representation, which can be conveniently transformed into a quadtree-based hierarchy suited for a joint importance sampling. Further, we propose sweep-space filtering, which suppresses the occurrence of fireflies and investigate different update schemes for animated scenes. Our technique is unbiased, requires little precomputation, is highly parallelizable, and is applicable to a various volume data sets, dynamic transfer functions, animated volumes and changing environmental lighting.

  17. Characterization of Macroinvertebrate Communities in the Hyporheic Zone of River Ecosystems Reflects the Pump-Sampling Technique Used

    PubMed Central

    Dole-Olivier, Marie-José; Galassi, Diana M. P.; Hogan, John-Paul; Wood, Paul J.

    2016-01-01

    The hyporheic zone of river ecosystems provides a habitat for a diverse macroinvertebrate community that makes a vital contribution to ecosystem functioning and biodiversity. However, effective methods for sampling this community have proved difficult to establish, due to the inaccessibility of subsurface sediments. The aim of this study was to compare the two most common semi-quantitative macroinvertebrate pump-sampling techniques: Bou-Rouch and vacuum-pump sampling. We used both techniques to collect replicate samples in three contrasting temperate-zone streams, in each of two biogeographical regions (Atlantic region, central England, UK; Continental region, southeast France). Results were typically consistent across streams in both regions: Bou-Rouch samples provided significantly higher estimates of taxa richness, macroinvertebrate abundance, and the abundance of all UK and eight of 10 French common taxa. Seven and nine taxa which were rare in Bou-Rouch samples were absent from vacuum-pump samples in the UK and France, respectively; no taxon was repeatedly sampled exclusively by the vacuum pump. Rarefaction curves (rescaled to the number of incidences) and non-parametric richness estimators indicated no significant difference in richness between techniques, highlighting the capture of more individuals as crucial to Bou-Rouch sampling performance. Compared to assemblages in replicate vacuum-pump samples, multivariate analyses indicated greater distinction among Bou-Rouch assemblages from different streams, as well as significantly greater consistency in assemblage composition among replicate Bou-Rouch samples collected in one stream. We recommend Bou-Rouch sampling for most study types, including rapid biomonitoring surveys and studies requiring acquisition of comprehensive taxon lists that include rare taxa. Despite collecting fewer macroinvertebrates, vacuum-pump sampling remains an important option for inexpensive and rapid sample collection. PMID:27723819

  18. A parameter selection for Raman spectroscopy-based detection of chemical contaminants in food powders

    USDA-ARS?s Scientific Manuscript database

    Raman spectroscopy technique has proven to be a reliable method for detection of chemical contaminants in food ingredients and products. To detect each contaminant particle in a food sample, it is important to determine the effective depth of penetration of laser through the food sample and the corr...

  19. Comparative quantification of Campylobacter jejuni from environmental samples using traditional and molecular biological techniques

    USDA-ARS?s Scientific Manuscript database

    Campylobacter jejuni (C. jejuni) is one of the most common causes of gastroenteritis in the world. Given the potential risks to human, animal and environmental health the development and optimization of methods to quantify this important pathogen in environmental samples is essential. Two of the mos...

  20. Molecular diagnosis of strongyloidiasis in a population of an endemic area through nested-PCR.

    PubMed

    Sharifdini, Meysam; Keyhani, Amir; Eshraghian, Mohammad Reza; Beigom Kia, Eshrat

    2018-01-01

    This study is aimed to diagnose and analyze strongyloidiasis in a population of an endemic area of Iran using nested-PCR, coupled with parasitological methods. Screening of strongyloidiasis infected people using reliable diagnostic techniques are essential to decrease the mortality and morbidity associated with this infection. Molecular methods have been proved to be highly sensitive and specific for detection of Strongyloides stercoralis in stool samples. A total of 155 fresh single stool samples were randomly collected from residents of north and northwest of Khouzestan Province, Iran. All samples were examined by parasitological methods including formalin-ether concentration and nutrient agar plate culture, and molecular method of nested-PCR. Infections with S. stercoralis were analyzed according to demographic criteria. Based on the results of nested-PCR method 15 cases (9.7%) were strongyloidiasis positive. Nested-PCR was more sensitive than parasitological techniques on single stool sampling. Elderly was the most important population index for higher infectivity with S. stercoralis . In endemic areas of S. stercoralis , old age should be considered as one of the most important risk factors of infection, especially among the immunosuppressed individuals.

  1. Advances in the Assessment of Wind Turbine Operating Extreme Loads via More Efficient Calculation Approaches

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Graf, Peter; Damiani, Rick R.; Dykes, Katherine

    2017-01-09

    A new adaptive stratified importance sampling (ASIS) method is proposed as an alternative approach for the calculation of the 50 year extreme load under operational conditions, as in design load case 1.1 of the the International Electrotechnical Commission design standard. ASIS combines elements of the binning and extrapolation technique, currently described by the standard, and of the importance sampling (IS) method to estimate load probability of exceedances (POEs). Whereas a Monte Carlo (MC) approach would lead to the sought level of POE with a daunting number of simulations, IS-based techniques are promising as they target the sampling of the inputmore » parameters on the parts of the distributions that are most responsible for the extreme loads, thus reducing the number of runs required. We compared the various methods on select load channels as output from FAST, an aero-hydro-servo-elastic tool for the design and analysis of wind turbines developed by the National Renewable Energy Laboratory (NREL). Our newly devised method, although still in its infancy in terms of tuning of the subparameters, is comparable to the others in terms of load estimation and its variance versus computational cost, and offers great promise going forward due to the incorporation of adaptivity into the already powerful importance sampling concept.« less

  2. Steady-state low thermal resistance characterization apparatus: The bulk thermal tester

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burg, Brian R.; Kolly, Manuel; Blasakis, Nicolas

    The reliability of microelectronic devices is largely dependent on electronic packaging, which includes heat removal. The appropriate packaging design therefore necessitates precise knowledge of the relevant material properties, including thermal resistance and thermal conductivity. Thin materials and high conductivity layers make their thermal characterization challenging. A steady state measurement technique is presented and evaluated with the purpose to characterize samples with a thermal resistance below 100 mm{sup 2} K/W. It is based on the heat flow meter bar approach made up by two copper blocks and relies exclusively on temperature measurements from thermocouples. The importance of thermocouple calibration is emphasizedmore » in order to obtain accurate temperature readings. An in depth error analysis, based on Gaussian error propagation, is carried out. An error sensitivity analysis highlights the importance of the precise knowledge of the thermal interface materials required for the measurements. Reference measurements on Mo samples reveal a measurement uncertainty in the range of 5% and most accurate measurements are obtained at high heat fluxes. Measurement techniques for homogeneous bulk samples, layered materials, and protruding cavity samples are discussed. Ultimately, a comprehensive overview of a steady state thermal characterization technique is provided, evaluating the accuracy of sample measurements with thermal resistances well below state of the art setups. Accurate characterization of materials used in heat removal applications, such as electronic packaging, will enable more efficient designs and ultimately contribute to energy savings.« less

  3. Micro/Nano-scale Strain Distribution Measurement from Sampling Moiré Fringes.

    PubMed

    Wang, Qinghua; Ri, Shien; Tsuda, Hiroshi

    2017-05-23

    This work describes the measurement procedure and principles of a sampling moiré technique for full-field micro/nano-scale deformation measurements. The developed technique can be performed in two ways: using the reconstructed multiplication moiré method or the spatial phase-shifting sampling moiré method. When the specimen grid pitch is around 2 pixels, 2-pixel sampling moiré fringes are generated to reconstruct a multiplication moiré pattern for a deformation measurement. Both the displacement and strain sensitivities are twice as high as in the traditional scanning moiré method in the same wide field of view. When the specimen grid pitch is around or greater than 3 pixels, multi-pixel sampling moiré fringes are generated, and a spatial phase-shifting technique is combined for a full-field deformation measurement. The strain measurement accuracy is significantly improved, and automatic batch measurement is easily achievable. Both methods can measure the two-dimensional (2D) strain distributions from a single-shot grid image without rotating the specimen or scanning lines, as in traditional moiré techniques. As examples, the 2D displacement and strain distributions, including the shear strains of two carbon fiber-reinforced plastic specimens, were measured in three-point bending tests. The proposed technique is expected to play an important role in the non-destructive quantitative evaluations of mechanical properties, crack occurrences, and residual stresses of a variety of materials.

  4. Compressed NMR: Combining compressive sampling and pure shift NMR techniques.

    PubMed

    Aguilar, Juan A; Kenwright, Alan M

    2017-12-26

    Historically, the resolution of multidimensional nuclear magnetic resonance (NMR) has been orders of magnitude lower than the intrinsic resolution that NMR spectrometers are capable of producing. The slowness of Nyquist sampling as well as the existence of signals as multiplets instead of singlets have been two of the main reasons for this underperformance. Fortunately, two compressive techniques have appeared that can overcome these limitations. Compressive sensing, also known as compressed sampling (CS), avoids the first limitation by exploiting the compressibility of typical NMR spectra, thus allowing sampling at sub-Nyquist rates, and pure shift techniques eliminate the second issue "compressing" multiplets into singlets. This paper explores the possibilities and challenges presented by this combination (compressed NMR). First, a description of the CS framework is given, followed by a description of the importance of combining it with the right pure shift experiment. Second, examples of compressed NMR spectra and how they can be combined with covariance methods will be shown. Copyright © 2017 John Wiley & Sons, Ltd.

  5. Investigation of spectral analysis techniques for randomly sampled velocimetry data

    NASA Technical Reports Server (NTRS)

    Sree, Dave

    1993-01-01

    It is well known that velocimetry (LV) generates individual realization velocity data that are randomly or unevenly sampled in time. Spectral analysis of such data to obtain the turbulence spectra, and hence turbulence scales information, requires special techniques. The 'slotting' technique of Mayo et al, also described by Roberts and Ajmani, and the 'Direct Transform' method of Gaster and Roberts are well known in the LV community. The slotting technique is faster than the direct transform method in computation. There are practical limitations, however, as to how a high frequency and accurate estimate can be made for a given mean sampling rate. These high frequency estimates are important in obtaining the microscale information of turbulence structure. It was found from previous studies that reliable spectral estimates can be made up to about the mean sampling frequency (mean data rate) or less. If the data were evenly samples, the frequency range would be half the sampling frequency (i.e. up to Nyquist frequency); otherwise, aliasing problem would occur. The mean data rate and the sample size (total number of points) basically limit the frequency range. Also, there are large variabilities or errors associated with the high frequency estimates from randomly sampled signals. Roberts and Ajmani proposed certain pre-filtering techniques to reduce these variabilities, but at the cost of low frequency estimates. The prefiltering acts as a high-pass filter. Further, Shapiro and Silverman showed theoretically that, for Poisson sampled signals, it is possible to obtain alias-free spectral estimates far beyond the mean sampling frequency. But the question is, how far? During his tenure under 1993 NASA-ASEE Summer Faculty Fellowship Program, the author investigated from his studies on the spectral analysis techniques for randomly sampled signals that the spectral estimates can be enhanced or improved up to about 4-5 times the mean sampling frequency by using a suitable prefiltering technique. But, this increased bandwidth comes at the cost of the lower frequency estimates. The studies further showed that large data sets of the order of 100,000 points, or more, high data rates, and Poisson sampling are very crucial for obtaining reliable spectral estimates from randomly sampled data, such as LV data. Some of the results of the current study are presented.

  6. Current trends in sample preparation for cosmetic analysis.

    PubMed

    Zhong, Zhixiong; Li, Gongke

    2017-01-01

    The widespread applications of cosmetics in modern life make their analysis particularly important from a safety point of view. There is a wide variety of restricted ingredients and prohibited substances that primarily influence the safety of cosmetics. Sample preparation for cosmetic analysis is a crucial step as the complex matrices may seriously interfere with the determination of target analytes. In this review, some new developments (2010-2016) in sample preparation techniques for cosmetic analysis, including liquid-phase microextraction, solid-phase microextraction, matrix solid-phase dispersion, pressurized liquid extraction, cloud point extraction, ultrasound-assisted extraction, and microwave digestion, are presented. Furthermore, the research and progress in sample preparation techniques and their applications in the separation and purification of allowed ingredients and prohibited substances are reviewed. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. A hybrid LIBS-Raman system combined with chemometrics: an efficient tool for plastic identification and sorting.

    PubMed

    Shameem, K M Muhammed; Choudhari, Khoobaram S; Bankapur, Aseefhali; Kulkarni, Suresh D; Unnikrishnan, V K; George, Sajan D; Kartha, V B; Santhosh, C

    2017-05-01

    Classification of plastics is of great importance in the recycling industry as the littering of plastic wastes increases day by day as a result of its extensive use. In this paper, we demonstrate the efficacy of a combined laser-induced breakdown spectroscopy (LIBS)-Raman system for the rapid identification and classification of post-consumer plastics. The atomic information and molecular information of polyethylene terephthalate, polyethylene, polypropylene, and polystyrene were studied using plasma emission spectra and scattered signal obtained in the LIBS and Raman technique, respectively. The collected spectral features of the samples were analyzed using statistical tools (principal component analysis, Mahalanobis distance) to categorize the plastics. The analyses of the data clearly show that elemental information and molecular information obtained from these techniques are efficient for classification of plastics. In addition, the molecular information collected via Raman spectroscopy exhibits clearly distinct features for the transparent plastics (100% discrimination), whereas the LIBS technique shows better spectral feature differences for the colored samples. The study shows that the information obtained from these complementary techniques allows the complete classification of the plastic samples, irrespective of the color or additives. This work further throws some light on the fact that the potential limitations of any of these techniques for sample identification can be overcome by the complementarity of these two techniques. Graphical Abstract ᅟ.

  8. Methods for trend analysis: Examples with problem/failure data

    NASA Technical Reports Server (NTRS)

    Church, Curtis K.

    1989-01-01

    Statistics are emphasized as an important role in quality control and reliability. Consequently, Trend Analysis Techniques recommended a variety of statistical methodologies that could be applied to time series data. The major goal of the working handbook, using data from the MSFC Problem Assessment System, is to illustrate some of the techniques in the NASA standard, some different techniques, and to notice patterns of data. Techniques for trend estimation used are: regression (exponential, power, reciprocal, straight line) and Kendall's rank correlation coefficient. The important details of a statistical strategy for estimating a trend component are covered in the examples. However, careful analysis and interpretation is necessary because of small samples and frequent zero problem reports in a given time period. Further investigations to deal with these issues are being conducted.

  9. Laser-induced breakdown spectroscopy application in environmental monitoring of water quality: a review.

    PubMed

    Yu, Xiaodong; Li, Yang; Gu, Xiaofeng; Bao, Jiming; Yang, Huizhong; Sun, Li

    2014-12-01

    Water quality monitoring is a critical part of environmental management and protection, and to be able to qualitatively and quantitatively determine contamination and impurity levels in water is especially important. Compared to the currently available water quality monitoring methods and techniques, laser-induced breakdown spectroscopy (LIBS) has several advantages, including no need for sample pre-preparation, fast and easy operation, and chemical free during the process. Therefore, it is of great importance to understand the fundamentals of aqueous LIBS analysis and effectively apply this technique to environmental monitoring. This article reviews the research conducted on LIBS analysis for liquid samples, and the article content includes LIBS theory, history and applications, quantitative analysis of metallic species in liquids, LIBS signal enhancement methods and data processing, characteristics of plasma generated by laser in water, and the factors affecting accuracy of analysis results. Although there have been many research works focusing on aqueous LIBS analysis, detection limit and stability of this technique still need to be improved to satisfy the requirements of environmental monitoring standard. In addition, determination of nonmetallic species in liquid by LIBS is equally important and needs immediate attention from the community. This comprehensive review will assist the readers to better understand the aqueous LIBS technique and help to identify current research needs for environmental monitoring of water quality.

  10. Field Validity and Feasibility of Four Techniques for the Detection of Trichuris in Simians: A Model for Monitoring Drug Efficacy in Public Health?

    PubMed Central

    Levecke, Bruno; De Wilde, Nathalie; Vandenhoute, Els; Vercruysse, Jozef

    2009-01-01

    Background Soil-transmitted helminths, such as Trichuris trichiura, are of major concern in public health. Current efforts to control these helminth infections involve periodic mass treatment in endemic areas. Since these large-scale interventions are likely to intensify, monitoring the drug efficacy will become indispensible. However, studies comparing detection techniques based on sensitivity, fecal egg counts (FEC), feasibility for mass diagnosis and drug efficacy estimates are scarce. Methodology/Principal Findings In the present study, the ether-based concentration, the Parasep Solvent Free (SF), the McMaster and the FLOTAC techniques were compared based on both validity and feasibility for the detection of Trichuris eggs in 100 fecal samples of nonhuman primates. In addition, the drug efficacy estimates of quantitative techniques was examined using a statistical simulation. Trichuris eggs were found in 47% of the samples. FLOTAC was the most sensitive technique (100%), followed by the Parasep SF (83.0% [95% confidence interval (CI): 82.4–83.6%]) and the ether-based concentration technique (76.6% [95% CI: 75.8–77.3%]). McMaster was the least sensitive (61.7% [95% CI: 60.7–62.6%]) and failed to detect low FEC. The quantitative comparison revealed a positive correlation between the four techniques (Rs = 0.85–0.93; p<0.0001). However, the ether-based concentration technique and the Parasep SF detected significantly fewer eggs than both the McMaster and the FLOTAC (p<0.0083). Overall, the McMaster was the most feasible technique (3.9 min/sample for preparing, reading and cleaning of the apparatus), followed by the ether-based concentration technique (7.7 min/sample) and the FLOTAC (9.8 min/sample). Parasep SF was the least feasible (17.7 min/sample). The simulation revealed that the sensitivity is less important for monitoring drug efficacy and that both FLOTAC and McMaster were reliable estimators. Conclusions/Significance The results of this study demonstrated that McMaster is a promising technique when making use of FEC to monitor drug efficacy in Trichuris. PMID:19172171

  11. Optical and structural properties of cadmium telluride films grown by glancing angle deposition

    NASA Astrophysics Data System (ADS)

    Ehsani, M. H.; Rezagholipour Dizaji, H.; Azizi, S.; Ghavami Mirmahalle, S. F.; Siyanaki, F. Hosseini

    2013-08-01

    Cadmium telluride films were grown by the glancing angle deposition (GLAD) technique. The samples were prepared under different incident deposition flux angles (α = 0°, 20° and 70° measured from the normal to the substrate surface). During deposition, the substrate temperature was maintained at room temperature. The structural study was performed using an x-ray diffraction diffractometer. The samples were found to be poly-crystalline with cubic structure for those deposited at α = 0° and 20° and hexagonal structure for the one deposited at 70°. The images of samples obtained by the field emission scanning electron microscopy technique showed that the GLAD method could produce a columnar layer tilted toward the incident deposition flux. The optical properties study by the UV-Vis spectroscopy technique showed that the use of this growth technique affected the optical properties of the films. A higher absorption coefficient in the visible and near-IR spectral range was observed for the sample deposited at α = 70°. This is an important result from the photovoltaic applications point of view where absorber materials with large absorption coefficients are needed. Also, it seems that the sample with a high incident deposition flux angle has the capability of making an n-CdTe/p-CdTe homo-junction.

  12. Accelerated spike resampling for accurate multiple testing controls.

    PubMed

    Harrison, Matthew T

    2013-02-01

    Controlling for multiple hypothesis tests using standard spike resampling techniques often requires prohibitive amounts of computation. Importance sampling techniques can be used to accelerate the computation. The general theory is presented, along with specific examples for testing differences across conditions using permutation tests and for testing pairwise synchrony and precise lagged-correlation between many simultaneously recorded spike trains using interval jitter.

  13. Immunogold scanning electron microscopy can reveal the polysaccharide architecture of xylem cell walls

    PubMed Central

    Sun, Yuliang; Juzenas, Kevin

    2017-01-01

    Abstract Immunofluorescence microscopy (IFM) and immunogold transmission electron microscopy (TEM) are the two main techniques commonly used to detect polysaccharides in plant cell walls. Both are important in localizing cell wall polysaccharides, but both have major limitations, such as low resolution in IFM and restricted sample size for immunogold TEM. In this study, we have developed a robust technique that combines immunocytochemistry with scanning electron microscopy (SEM) to study cell wall polysaccharide architecture in xylem cells at high resolution over large areas of sample. Using multiple cell wall monoclonal antibodies (mAbs), this immunogold SEM technique reliably localized groups of hemicellulosic and pectic polysaccharides in the cell walls of five different xylem structures (vessel elements, fibers, axial and ray parenchyma cells, and tyloses). This demonstrates its important advantages over the other two methods for studying cell wall polysaccharide composition and distribution in these structures. In addition, it can show the three-dimensional distribution of a polysaccharide group in the vessel lateral wall and the polysaccharide components in the cell wall of developing tyloses. This technique, therefore, should be valuable for understanding the cell wall polysaccharide composition, architecture and functions of diverse cell types. PMID:28398585

  14. Actinide bioimaging in tissues: Comparison of emulsion and solid track autoradiography techniques with the iQID camera

    PubMed Central

    Miller, Brian W.; Van der Meeren, Anne; Tazrart, Anissa; Angulo, Jaime F.; Griffiths, Nina M.

    2017-01-01

    This work presents a comparison of three autoradiography techniques for imaging biological samples contaminated with actinides: emulsion-based, plastic-based autoradiography and a quantitative digital technique, the iQID camera, based on the numerical analysis of light from a scintillator screen. In radiation toxicology it has been important to develop means of imaging actinide distribution in tissues as these radionuclides may be heterogeneously distributed within and between tissues after internal contamination. Actinide distribution determines which cells are exposed to alpha radiation and is thus potentially critical for assessing absorbed dose. The comparison was carried out by generating autoradiographs of the same biological samples contaminated with actinides with the three autoradiography techniques. These samples were cell preparations or tissue sections collected from animals contaminated with different physico-chemical forms of actinides. The autoradiograph characteristics and the performances of the techniques were evaluated and discussed mainly in terms of acquisition process, activity distribution patterns, spatial resolution and feasibility of activity quantification. The obtained autoradiographs presented similar actinide distribution at low magnification. Out of the three techniques, emulsion autoradiography is the only one to provide a highly-resolved image of the actinide distribution inherently superimposed on the biological sample. Emulsion autoradiography is hence best interpreted at higher magnifications. However, this technique is destructive for the biological sample. Both emulsion- and plastic-based autoradiography record alpha tracks and thus enabled the differentiation between ionized forms of actinides and oxide particles. This feature can help in the evaluation of decorporation therapy efficacy. The most recent technique, the iQID camera, presents several additional features: real-time imaging, separate imaging of alpha particles and gamma rays, and alpha activity quantification. The comparison of these three autoradiography techniques showed that they are complementary and the choice of the technique depends on the purpose of the imaging experiment. PMID:29023595

  15. Ultrasonic characterization of granites obtained from industrial quarries of Extremadura (Spain).

    PubMed

    del Río, L M; López, F; Esteban, F J; Tejado, J J; Mota, M; González, I; San Emeterio, J L; Ramos, A

    2006-12-22

    The industry of ornamental rocks, such as granites, represents one of the most important industrial activities in the region of Extremadura, SW Spain. A detailed knowledge of the intrinsic properties of this natural stone and its environmental evolution is a required goal in order to fully characterize its quality. In this work, two independent NDT acoustic techniques have been used to measure the acoustic velocity of longitudinal waves in different prismatic granitic-samples of industrial quarries. A low-frequency transceiver set-up, based on a high-voltage BPV Steinkamp instrument and two 50 kHz probes, has been used to measure pulse travel times by ultrasonic through-transmission testing. In complementary fashion, an Erudite MK3 test equipment with an electromagnetic vibrator and two piezoelectric sensors has also been employed to measure ultrasonic velocity by means of a resonance-based method, using the same types of granite varieties. In addition, a comprehensive set of physical/mechanical properties have also been analyzed, according to Spanish regulations in force, by means of alternative methods including destructive techniques such as strength, porosity, absorption, etc. A large number of samples, representing the most important varieties of granites from quarries of Extremadura, have been analyzed using the above-mentioned procedures. Some results obtained by destructive techniques have been correlated with those found using ultrasonic techniques. Our experimental setting allowed a complementary characterization of granite samples and a thorough validation of the different techniques employed, thus providing the industry of ornamental rocks with a non-destructive tool that will facilitate a more detailed insight on the properties of the rocks under study.

  16. Development of mass spectrometric techniques applicable to the search for organic matter in the lunar crust

    NASA Technical Reports Server (NTRS)

    Biemann, K.

    1973-01-01

    Data processing techniques were developed to measure with high precision and sensitivity the line spectra produced by a high resolution mass spectrometer. The most important aspect of this phase was the interfacing of a modified precision microphotometer-comparator with a computer and the improvement of existing software to serve the special needs of the investigation of lunar samples. In addition, a gas-chromatograph mass spectrometer system was interfaced with the same computer to allow continuous recording of mass spectra on a gas chromatographic effluent and efficient evaluation of the resulting data. These techniques were then used to detect and identify organic compounds present in the samples returned by the Apollo 11 and 12 missions.

  17. Development of methodologies for identification and quantification of hazardous air pollutants from turbine engine emissions.

    PubMed

    Anneken, David; Striebich, Richard; DeWitt, Matthew J; Klingshirn, Christopher; Corporan, Edwin

    2015-03-01

    Aircraft turbine engines are a significant source of particulate matter (PM) and gaseous emissions in the vicinity of airports and military installations. Hazardous air pollutants (HAPs) (e.g., formaldehyde, benzene, naphthalene and other compounds) associated with aircraft emissions are an environmental concern both in flight and at ground level. Therefore, effective sampling, identification, and accurate measurement of these trace species are important to assess their environmental impact. This effort evaluates two established ambient air sampling and analysis methods, U.S. Environmental Protection Agency (EPA) Method TO-11A and National Institute for Occupational Safety and Health (NIOSH) Method 1501, for potential use to quantify HAPs from aircraft turbine engines. The techniques were used to perform analysis of the exhaust from a T63 turboshaft engine, and were examined using certified gas standards transferred through the heated sampling systems used for engine exhaust gaseous emissions measurements. Test results show that the EPA Method TO-11A (for aldehydes) and NIOSH Method 1501 (for semivolatile hydrocarbons) were effective techniques for the sampling and analysis of most HAPs of interest. Both methods showed reasonable extraction efficiencies of HAP species from the sorbent tubes, with the exception of acrolein, styrene, and phenol, which were not well quantified. Formaldehyde measurements using dinitrophenylhydrazine (DNPH) tubes (EPA method TO-11A) were accurate for gas-phase standards, and compared favorably to measurements using gas-phase Fourier-transform infrared (FTIR) spectroscopy. In general, these two standard methodologies proved to be suitable techniques for field measurement of turbine engine HAPs within a reasonable (5-10 minutes) sampling period. Details of the tests, the analysis methods, calibration procedures, and results from the gas standards and T63 engine tested using a conventional JP-8 jet fuel are provided. HAPs from aviation-related sources are important because of their adverse health and environmental impacts in and around airports and flight lines. Simpler, more convenient techniques to measure the important HAPs, especially aldehydes and volatile organic HAPs, are needed to provide information about their occurrence and assist in the development of engines that emit fewer harmful emissions.

  18. Autonomous spatially adaptive sampling in experiments based on curvature, statistical error and sample spacing with applications in LDA measurements

    NASA Astrophysics Data System (ADS)

    Theunissen, Raf; Kadosh, Jesse S.; Allen, Christian B.

    2015-06-01

    Spatially varying signals are typically sampled by collecting uniformly spaced samples irrespective of the signal content. For signals with inhomogeneous information content, this leads to unnecessarily dense sampling in regions of low interest or insufficient sample density at important features, or both. A new adaptive sampling technique is presented directing sample collection in proportion to local information content, capturing adequately the short-period features while sparsely sampling less dynamic regions. The proposed method incorporates a data-adapted sampling strategy on the basis of signal curvature, sample space-filling, variable experimental uncertainty and iterative improvement. Numerical assessment has indicated a reduction in the number of samples required to achieve a predefined uncertainty level overall while improving local accuracy for important features. The potential of the proposed method has been further demonstrated on the basis of Laser Doppler Anemometry experiments examining the wake behind a NACA0012 airfoil and the boundary layer characterisation of a flat plate.

  19. Sample preparation techniques for the determination of natural 15N/14N variations in amino acids by gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS).

    PubMed

    Hofmann, D; Gehre, M; Jung, K

    2003-09-01

    In order to identify natural nitrogen isotope variations of biologically important amino acids four derivatization reactions (t-butylmethylsilylation, esterification with subsequent trifluoroacetylation, acetylation and pivaloylation) were tested with standard mixtures of 17 proteinogenic amino acids and plant (moss) samples using GC-C-IRMS. The possible fractionation of the nitrogen isotopes, caused for instance by the formation of multiple reaction products, was investigated. For biological samples, the esterification of the amino acids with subsequent trifluoroacetylation is recommended for nitrogen isotope ratio analysis. A sample preparation technique is described for the isotope ratio mass spectrometric analysis of amino acids from the non-protein (NPN) fraction of terrestrial moss. 14N/15N ratios from moss (Scleropodium spec.) samples from different anthropogenically polluted areas were studied with respect to ecotoxicologal bioindication.

  20. Using machine learning to accelerate sampling-based inversion

    NASA Astrophysics Data System (ADS)

    Valentine, A. P.; Sambridge, M.

    2017-12-01

    In most cases, a complete solution to a geophysical inverse problem (including robust understanding of the uncertainties associated with the result) requires a sampling-based approach. However, the computational burden is high, and proves intractable for many problems of interest. There is therefore considerable value in developing techniques that can accelerate sampling procedures.The main computational cost lies in evaluation of the forward operator (e.g. calculation of synthetic seismograms) for each candidate model. Modern machine learning techniques-such as Gaussian Processes-offer a route for constructing a computationally-cheap approximation to this calculation, which can replace the accurate solution during sampling. Importantly, the accuracy of the approximation can be refined as inversion proceeds, to ensure high-quality results.In this presentation, we describe and demonstrate this approach-which can be seen as an extension of popular current methods, such as the Neighbourhood Algorithm, and bridges the gap between prior- and posterior-sampling frameworks.

  1. Estimating TCP Packet Loss Ratio from Sampled ACK Packets

    NASA Astrophysics Data System (ADS)

    Yamasaki, Yasuhiro; Shimonishi, Hideyuki; Murase, Tutomu

    The advent of various quality-sensitive applications has greatly changed the requirements for IP network management and made the monitoring of individual traffic flows more important. Since the processing costs of per-flow quality monitoring are high, especially in high-speed backbone links, packet sampling techniques have been attracting considerable attention. Existing sampling techniques, such as those used in Sampled NetFlow and sFlow, however, focus on the monitoring of traffic volume, and there has been little discussion of the monitoring of such quality indexes as packet loss ratio. In this paper we propose a method for estimating, from sampled packets, packet loss ratios in individual TCP sessions. It detects packet loss events by monitoring duplicate ACK events raised by each TCP receiver. Because sampling reveals only a portion of the actual packet loss, the actual packet loss ratio is estimated statistically. Simulation results show that the proposed method can estimate the TCP packet loss ratio accurately from a 10% sampling of packets.

  2. Cryptosporidium Oocyst Detection in Water Samples: Floatation Technique Enhanced with Immunofluorescence Is as Effective as Immunomagnetic Separation Method

    PubMed Central

    Koompapong, Khuanchai; Sutthikornchai, Chantira

    2009-01-01

    Cryptosporidium can cause gastrointestinal diseases worldwide, consequently posing public health problems and economic burden. Effective techniques for detecting contaminated oocysts in water are important to prevent and control the contamination. Immunomagnetic separation (IMS) method has been widely employed recently due to its efficiency, but, it is costly. Sucrose floatation technique is generally used for separating organisms by using their different specific gravity. It is effective and cheap but time consuming as well as requiring highly skilled personnel. Water turbidity and parasite load in water sample are additional factors affecting to the recovery rate of those 2 methods. We compared the efficiency of IMS and sucrose floatation methods to recover the spiked Cryptosporidium oocysts in various turbidity water samples. Cryptosporidium oocysts concentration at 1, 101, 102, and 103 per 10 µl were spiked into 3 sets of 10 ml-water turbidity (5, 50, and 500 NTU). The recovery rate of the 2 methods was not different. Oocyst load at the concentration < 102 per 10 ml yielded unreliable results. Water turbidity at 500 NTU decreased the recovery rate of both techniques. The combination of sucrose floatation and immunofluorescense assay techniques (SF-FA) showed higher recovery rate than IMS and immunofluorescense assay (IMS-FA). We used this SF-FA to detect Cryptosporidium and Giardia from the river water samples and found 9 and 19 out of 30 (30% and 63.3%) positive, respectively. Our results favored sucrose floatation technique enhanced with immunofluorescense assay for detecting contaminated protozoa in water samples in general laboratories and in the real practical setting. PMID:19967082

  3. Cryptosporidium oocyst detection in water samples: floatation technique enhanced with immunofluorescence is as effective as immunomagnetic separation method.

    PubMed

    Koompapong, Khuanchai; Sutthikornchai, Chantira; Sukthana, Yowalark

    2009-12-01

    Cryptosporidium can cause gastrointestinal diseases worldwide, consequently posing public health problems and economic burden. Effective techniques for detecting contaminated oocysts in water are important to prevent and control the contamination. Immunomagnetic separation (IMS) method has been widely employed recently due to its efficiency, but, it is costly. Sucrose floatation technique is generally used for separating organisms by using their different specific gravity. It is effective and cheap but time consuming as well as requiring highly skilled personnel. Water turbidity and parasite load in water sample are additional factors affecting to the recovery rate of those 2 methods. We compared the efficiency of IMS and sucrose floatation methods to recover the spiked Cryptosporidium oocysts in various turbidity water samples. Cryptosporidium oocysts concentration at 1, 10(1), 10(2), and 10(3) per 10 microl were spiked into 3 sets of 10 ml-water turbidity (5, 50, and 500 NTU). The recovery rate of the 2 methods was not different. Oocyst load at the concentration < 10(2) per 10 ml yielded unreliable results. Water turbidity at 500 NTU decreased the recovery rate of both techniques. The combination of sucrose floatation and immunofluorescense assay techniques (SF-FA) showed higher recovery rate than IMS and immunofluorescense assay (IMS-FA). We used this SF-FA to detect Cryptosporidium and Giardia from the river water samples and found 9 and 19 out of 30 (30% and 63.3%) positive, respectively. Our results favored sucrose floatation technique enhanced with immunofluorescense assay for detecting contaminated protozoa in water samples in general laboratories and in the real practical setting.

  4. A novel hybrid scattering order-dependent variance reduction method for Monte Carlo simulations of radiative transfer in cloudy atmosphere

    NASA Astrophysics Data System (ADS)

    Wang, Zhen; Cui, Shengcheng; Yang, Jun; Gao, Haiyang; Liu, Chao; Zhang, Zhibo

    2017-03-01

    We present a novel hybrid scattering order-dependent variance reduction method to accelerate the convergence rate in both forward and backward Monte Carlo radiative transfer simulations involving highly forward-peaked scattering phase function. This method is built upon a newly developed theoretical framework that not only unifies both forward and backward radiative transfer in scattering-order-dependent integral equation, but also generalizes the variance reduction formalism in a wide range of simulation scenarios. In previous studies, variance reduction is achieved either by using the scattering phase function forward truncation technique or the target directional importance sampling technique. Our method combines both of them. A novel feature of our method is that all the tuning parameters used for phase function truncation and importance sampling techniques at each order of scattering are automatically optimized by the scattering order-dependent numerical evaluation experiments. To make such experiments feasible, we present a new scattering order sampling algorithm by remodeling integral radiative transfer kernel for the phase function truncation method. The presented method has been implemented in our Multiple-Scaling-based Cloudy Atmospheric Radiative Transfer (MSCART) model for validation and evaluation. The main advantage of the method is that it greatly improves the trade-off between numerical efficiency and accuracy order by order.

  5. Wang-Landau method for calculating Rényi entropies in finite-temperature quantum Monte Carlo simulations.

    PubMed

    Inglis, Stephen; Melko, Roger G

    2013-01-01

    We implement a Wang-Landau sampling technique in quantum Monte Carlo (QMC) simulations for the purpose of calculating the Rényi entanglement entropies and associated mutual information. The algorithm converges an estimate for an analog to the density of states for stochastic series expansion QMC, allowing a direct calculation of Rényi entropies without explicit thermodynamic integration. We benchmark results for the mutual information on two-dimensional (2D) isotropic and anisotropic Heisenberg models, a 2D transverse field Ising model, and a three-dimensional Heisenberg model, confirming a critical scaling of the mutual information in cases with a finite-temperature transition. We discuss the benefits and limitations of broad sampling techniques compared to standard importance sampling methods.

  6. Fast simulation of packet loss rates in a shared buffer communications switch

    NASA Technical Reports Server (NTRS)

    Chang, Cheng-Shang; Heidelberger, Philip; Shahabuddin, Perwez

    1993-01-01

    This paper describes an efficient technique for estimating, via simulation, the probability of buffer overflows in a queueing model that arises in the analysis of ATM (Asynchronous Transfer Mode) communication switches. There are multiple streams of (autocorrelated) traffic feeding the switch that has a buffer of finite capacity. Each stream is designated as either being of high or low priority. When the queue length reaches a certain threshold, only high priority packets are admitted to the switch's buffer. The problem is to estimate the loss rate of high priority packets. An asymptotically optimal importance sampling approach is developed for this rare event simulation problem. In this approach, the importance sampling is done in two distinct phases. In the first phase, an importance sampling change of measure is used to bring the queue length up to the threshold at which low priority packets get rejected. In the second phase, a different importance sampling change of measure is used to move the queue length from the threshold to the buffer capacity.

  7. Flow analysis techniques for phosphorus: an overview.

    PubMed

    Estela, José Manuel; Cerdà, Víctor

    2005-04-15

    A bibliographical review on the implementation and the results obtained in the use of different flow analytical techniques for the determination of phosphorus is carried out. The sources, occurrence and importance of phosphorus together with several aspects regarding the analysis and terminology used in the determination of this element are briefly described. A classification as well as a brief description of the basis, advantages and disadvantages of the different existing flow techniques, namely; segmented flow analysis (SFA), flow injection analysis (FIA), sequential injection analysis (SIA), all injection analysis (AIA), batch injection analysis (BIA), multicommutated FIA (MCFIA), multisyringe FIA (MSFIA) and multipumped FIA (MPFIA) is also carried out. The most relevant manuscripts regarding the analysis of phosphorus by means of flow techniques are herein classified according to the detection instrumental technique used with the aim to facilitate their study and obtain an overall scope. Finally, the analytical characteristics of numerous flow-methods reported in the literature are provided in the form of a table and their applicability to samples with different matrixes, namely water samples (marine, river, estuarine, waste, industrial, drinking, etc.), soils leachates, plant leaves, toothpaste, detergents, foodstuffs (wine, orange juice, milk), biological samples, sugars, fertilizer, hydroponic solutions, soils extracts and cyanobacterial biofilms are tabulated.

  8. Toxic metals in imported fruits and vegetables marketed in Kuwait

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Husain, A.; Baroon, Z.; Al-Khalafawi, M.

    1995-12-31

    The concentration of lead, cadmium, and mercury in 134 samples of imported fruits and vegetables marketed in Kuwait were determined using an atomic absorption spectrophotometer with a graphite furnace and the cold vapor technique. Results obtained showed that the concentration of these metal ions in most cases did not exceed the maximum permissible concentration of metals in fresh fruits and vegetables as restricted by some countries. Only a few samples of fruits and vegetables contained levels of mercury, cadmium, and lead which exceeded these maximum permissible levels.

  9. Determination of technetium-99 in environmental samples: a review.

    PubMed

    Shi, Keliang; Hou, Xiaolin; Roos, Per; Wu, Wangsuo

    2012-01-04

    Due to the lack of a stable technetium isotope, and the high mobility and long half-life, (99)Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. (99)Tc is also an important tracer for oceanographic research due to the high technetium solubility in seawater as TcO(4)(-). A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of (99)Tc in different environmental samples. This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of (99)Tc. Due to the extremely low concentration of (99)Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal of the interferences for detection of (99)Tc are the most important issues governing the accurate determination of (99)Tc. These aspects are discussed in detail in this article. Meanwhile, the different measurement techniques for (99)Tc are also compared with respect to advantages and drawbacks. Novel automated analytical methods for rapid determination of (99)Tc using solid extraction or ion exchange chromatography for separation of (99)Tc, employing flow injection or sequential injection approaches are also discussed. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Multi-object investigation using two-wavelength phase-shift interferometry guided by an optical frequency comb

    NASA Astrophysics Data System (ADS)

    Ibrahim, Dahi Ghareab Abdelsalam; Yasui, Takeshi

    2018-04-01

    Two-wavelength phase-shift interferometry guided by optical frequency combs is presented. We demonstrate the operation of the setup with a large step sample simultaneously with a resolution test target with a negative pattern. The technique can investigate multi-objects simultaneously with high precision. Using this technique, several important applications in metrology that require high speed and precision are demonstrated.

  11. Proteomic patterns for classification of ovarian cancer and CTCL serum samples utilizing peak pairs indicative of post-translational modifications.

    PubMed

    Liu, Chenwei; Shea, Nancy; Rucker, Sally; Harvey, Linda; Russo, Paul; Saul, Richard; Lopez, Mary F; Mikulskis, Alvydas; Kuzdzal, Scott; Golenko, Eva; Fishman, David; Vonderheid, Eric; Booher, Susan; Cowen, Edward W; Hwang, Sam T; Whiteley, Gordon R

    2007-11-01

    Proteomic patterns as a potential diagnostic technology has been well established for several cancer conditions and other diseases. The use of machine learning techniques such as decision trees, neural networks, genetic algorithms, and other methods has been the basis for pattern determination. Cancer is known to involve signaling pathways that are regulated through PTM of proteins. These modifications are also detectable with high confidence using high-resolution MS. We generated data using a prOTOF mass spectrometer on two sets of patient samples: ovarian cancer and cutaneous t-cell lymphoma (CTCL) with matched normal samples for each disease. Using the knowledge of mass shifts caused by common modifications, we built models using peak pairs and compared this to a conventional technique using individual peaks. The results for each disease showed that a small number of peak pairs gave classification equal to or better than the conventional technique that used multiple individual peaks. This simple peak picking technique could be used to guide identification of important peak pairs involved in the disease process.

  12. Environmental Monitoring and the Gas Industry: Program Manager Handbook

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gregory D. Gillispie

    1997-12-01

    This document has been developed for the nontechnical gas industry manager who has the responsibility for the development of waste or potentially contaminated soil and groundwater data or must make decisions based on such data for the management or remediation of these materials. It explores the pse of common analytical chemistry instrumentation and associated techniques for identification of environmentally hazardous materials. Sufficient detail is given to familiarize the nontechnical reader with the principles behind the operation of each technique. The scope and realm of the techniques and their constituent variations are portrayed through a discussion of crucial details and, wheremore » appropriate, the depiction of real-life data. It is the author's intention to provide an easily understood handbook for gas industry management. Techniques which determine the presence, composition, and quantification of gas industry wastes are discussed. Greater focus is given to traditional techniques which have been the mainstay of modem analytical benchwork. However, with the continual advancement of instrumental principles and design, several techniques have been included which are likely to receive greater attention in fiture considerations for waste-related detection. Definitions and concepts inherent to a thorough understanding of the principles common to analytical chemistry are discussed. It is also crucial that gas industry managers understand the effects of the various actions which take place before, during, and after the actual sampling step. When a series of sample collection, storage, and transport activities occur, new or inexperienced project managers may overlook or misunderstand the importance of the sequence. Each step has an impact on the final results of the measurement process; errors in judgment or decision making can be costly. Specific techniques and methodologies for the collection, storage, and transport of environmental media samples are not described or discussed in detail in thk handbook. However, the underlying philosophy regarding the importance of proper collection, storage, and transport practices, as well as pertinent references, are presented.« less

  13. The external morphology of adult female Egrasilus labracis as shown using hexamethyldisilazane treated, uncoated specimens for scanning electron microscopy.

    PubMed

    Murray, Harry M; Hill, Stephen J; Ang, Keng P

    2016-07-01

    The description and application of a modified Scanning Electron Microscope preparation technique using hexamethyldisilazane for small parasitic copepods was demonstrated though a high resolution depiction of individuals of Ergasilus labracis sampled from three spined stickleback (Gasterosteus aculeatus) in Bay D'Espoir, Newfoundland during summer 2015 and from archival samples retrieved from Atlantic salmon par (Salmo salar) stored at the Atlantic reference centre, St. Andrews, New Brunswick. The specimens were very well preserved showing high quality detail of important features and verifying those previously described using light microscopy by Hogans. Additionally the technique allowed excellent in situ demonstrations of mouth parts, swimming legs, and unusual and previously undescribed features of the second antenna including prominent striations and pore-like structures found to define the claw. It is thought that this technique will become a quick and efficient tool for describing important taxonomic features of small parasitic copepods like E. labracis or other similar small aquatic organisms. Microsc. Res. Tech. 79:657-663, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  14. Radiochemical determination of 241Am and Pu(alpha) in environmental materials.

    PubMed

    Warwick, P E; Croudace, I W; Oh, J S

    2001-07-15

    Americium-241 and plutonium determinations will become of greater importance over the coming decades as 137Cs and 241Pu decay. The impact of 137Cs on environmental chronology has been great, but its potency is waning as it decays and diffuses. Having 241Am and Pu as unequivocal markers for the 1963 weapon fallout maximum is important for short time scale environmental work, but a fast and reliable procedure is required for their separation. The developed method described here begins by digesting samples using a lithium borate fusion although an aqua regia leachate is also effective in many instances. Isolation of the Am and Pu is then achieved using a combination of extraction chromatography and conventional anion exchange chromatography. The whole procedure has been optimized, validated, and assessed for safety. The straightforwardness of this technique permits the analysis of large numbers of samples and makes 241Am-based techniques for high-resolution sediment accumulation rate studies attractive. In addition, the technique can be employed for the sequential measurement of Pu and Am in environmental surveillance programs, potentially reducing analytical costs and turnround times.

  15. Aerobiology: Experimental Considerations, Observations, and Future Tools

    PubMed Central

    Haddrell, Allen E.

    2017-01-01

    ABSTRACT Understanding airborne survival and decay of microorganisms is important for a range of public health and biodefense applications, including epidemiological and risk analysis modeling. Techniques for experimental aerosol generation, retention in the aerosol phase, and sampling require careful consideration and understanding so that they are representative of the conditions the bioaerosol would experience in the environment. This review explores the current understanding of atmospheric transport in relation to advances and limitations of aerosol generation, maintenance in the aerosol phase, and sampling techniques. Potential tools for the future are examined at the interface between atmospheric chemistry, aerosol physics, and molecular microbiology where the heterogeneity and variability of aerosols can be explored at the single-droplet and single-microorganism levels within a bioaerosol. The review highlights the importance of method comparison and validation in bioaerosol research and the benefits that the application of novel techniques could bring to increasing the understanding of aerobiological phenomena in diverse research fields, particularly during the progression of atmospheric transport, where complex interdependent physicochemical and biological processes occur within bioaerosol particles. PMID:28667111

  16. Sampling Plans for the Thrips Frankliniella schultzei (Thysanoptera: Thripidae) in Three Lettuce Varieties.

    PubMed

    Silva, Alisson R; Rodrigues-Silva, Nilson; Pereira, Poliana S; Sarmento, Renato A; Costa, Thiago L; Galdino, Tarcísio V S; Picanço, Marcelo C

    2017-12-05

    The common blossom thrips, Frankliniella schultzei Trybom (Thysanoptera: Thripidae), is an important lettuce pest worldwide. Conventional sampling plans are the first step in implementing decision-making systems into integrated pest management programs. However, this tool is not available for F. schultzei infesting lettuce crops. Thus, the objective of this work was to develop a conventional sampling plan for F. schultzei in lettuce crops. Two sampling techniques (direct counting and leaf beating on a white plastic tray) were compared in crisphead, looseleaf, and Boston lettuce varieties before and during head formation. The frequency distributions of F. schultzei densities in lettuce crops were assessed, and the number of samples required to compose the sampling plan was determined. Leaf beating on a white plastic tray was the best sampling technique. F. schultzei densities obtained with this technique were fitted to the negative binomial distribution with a common aggregation parameter (common K = 0.3143). The developed sampling plan is composed of 91 samples per field and presents low errors in its estimates (up to 20%), fast execution time (up to 47 min), and low cost (up to US $1.67 per sampling area). This sampling plan can be used as a tool for integrated pest management in lettuce crops, assisting with reliable decision making in different lettuce varieties before and during head formation. © The Author(s) 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  17. Forensic Comparison of Soil Samples Using Nondestructive Elemental Analysis.

    PubMed

    Uitdehaag, Stefan; Wiarda, Wim; Donders, Timme; Kuiper, Irene

    2017-07-01

    Soil can play an important role in forensic cases in linking suspects or objects to a crime scene by comparing samples from the crime scene with samples derived from items. This study uses an adapted ED-XRF analysis (sieving instead of grinding to prevent destruction of microfossils) to produce elemental composition data of 20 elements. Different data processing techniques and statistical distances were evaluated using data from 50 samples and the log-LR cost (C llr ). The best performing combination, Canberra distance, relative data, and square root values, is used to construct a discriminative model. Examples of the spatial resolution of the method in crime scenes are shown for three locations, and sampling strategy is discussed. Twelve test cases were analyzed, and results showed that the method is applicable. The study shows how the combination of an analysis technique, a database, and a discriminative model can be used to compare multiple soil samples quickly. © 2016 American Academy of Forensic Sciences.

  18. Reservoir characteristics of coal-shale sedimentary sequence in coal-bearing strata and their implications for the accumulation of unconventional gas

    NASA Astrophysics Data System (ADS)

    Wang, Yang; Zhu, Yanming; Liu, Yu; Chen, Shangbin

    2018-04-01

    Shale gas and coalbed methane (CBM) are both considered unconventional natural gas and are becoming increasingly important energy resources. In coal-bearing strata, coal and shale are vertically adjacent as coal and shale are continuously deposited. Research on the reservoir characteristics of coal-shale sedimentary sequences is important for CBM and coal-bearing shale gas exploration. In this study, a total of 71 samples were collected, including coal samples (total organic carbon (TOC) content >40%), carbonaceous shale samples (TOC content: 6%-10%), and shale samples (TOC content <6%). Combining techniques of field emission scanning electron microscopy (FE-SEM), x-ray diffraction, high-pressure mercury intrusion porosimetry, and methane adsorption, experiments were employed to characterize unconventional gas reservoirs in coal-bearing strata. The results indicate that in the coal-shale sedimentary sequence, the proportion of shale is the highest at 74% and that of carbonaceous shale and coal are 14% and 12%, respectively. The porosity of all measured samples demonstrates a good positive relationship with TOC content. Clay and quartz also have a great effect on the porosity of shale samples. According to the FE-SEM image technique, nanoscale pores in the organic matter of coal samples are much more developed compared with shale samples. For shales with low TOC, inorganic minerals provide more pores than organic matter. In addition, TOC content has a positive relationship with methane adsorption capacity, and the adsorption capacity of coal samples is more sensitive than the shale samples to temperature.

  19. Determination of Se in soil samples using the proton induced X-ray emission technique

    NASA Astrophysics Data System (ADS)

    Cruvinel, Paulo E.; Flocchini, Robert G.

    1993-04-01

    An alternative method for the direct determination of total Se in soil samples is presented. A large number of trace elements is present in soil at concentration values in the range of part per billion and tenths of parts of million. The most common are the trace elements of Al, Si, K, Ca, Ti, V, Cr, Fe, Cu, Zn, Br, Rb, Mo, Cd and Pb. As for biological samples many of these elements are of great importance for the nutrition of plants, while others are toxic and others have an unknown role. Selenium is an essential micronutrient for humans and animals but it is also known that in certain areas Se deficiency or toxicity has caused endemic disease to livestock and humans through the soil-plant-animal linkage. In this work the suitability of the proton induced X-ray emission (PIXE) technique as a fast and nondestructive technique useful to measure total the Se content in soil samples is demonstrated. To validate the results a comparison of data collected using the conventional atomic absorption spectrophotometry (AAS) method was performed.

  20. 9 CFR 381.196 - Eligibility of foreign countries for importation of poultry products into the United States.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... processed for export to the United States; (E) Complete separation of establishments certified under... potential contaminants, in accordance with sampling and analytical techniques approved by the Administrator...

  1. 9 CFR 381.196 - Eligibility of foreign countries for importation of poultry products into the United States.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... processed for export to the United States; (E) Complete separation of establishments certified under... potential contaminants, in accordance with sampling and analytical techniques approved by the Administrator...

  2. 9 CFR 381.196 - Eligibility of foreign countries for importation of poultry products into the United States.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... processed for export to the United States; (E) Complete separation of establishments certified under... potential contaminants, in accordance with sampling and analytical techniques approved by the Administrator...

  3. DNA stable-isotope probing (DNA-SIP).

    PubMed

    Dunford, Eric A; Neufeld, Josh D

    2010-08-02

    DNA stable-isotope probing (DNA-SIP) is a powerful technique for identifying active microorganisms that assimilate particular carbon substrates and nutrients into cellular biomass. As such, this cultivation-independent technique has been an important methodology for assigning metabolic function to the diverse communities inhabiting a wide range of terrestrial and aquatic environments. Following the incubation of an environmental sample with stable-isotope labelled compounds, extracted nucleic acid is subjected to density gradient ultracentrifugation and subsequent gradient fractionation to separate nucleic acids of differing densities. Purification of DNA from cesium chloride retrieves labelled and unlabelled DNA for subsequent molecular characterization (e.g. fingerprinting, microarrays, clone libraries, metagenomics). This JoVE video protocol provides visual step-by-step explanations of the protocol for density gradient ultracentrifugation, gradient fractionation and recovery of labelled DNA. The protocol also includes sample SIP data and highlights important tips and cautions that must be considered to ensure a successful DNA-SIP analysis.

  4. General statistical considerations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eberhardt, L L; Gilbert, R O

    From NAEG plutonium environmental studies program meeting; Las Vegas, Nevada, USA (2 Oct 1973). The high sampling variability encountered in environmental plutonium studies along with high analytical costs makes it very important that efficient soil sampling plans be used. However, efficient sampling depends on explicit and simple statements of the objectives of the study. When there are multiple objectives it may be difficult to devise a wholly suitable sampling scheme. Sampling for long-term changes in plutonium concentration in soils may also be complex and expensive. Further attention to problems associated with compositing samples is recommended, as is the consistent usemore » of random sampling as a basic technique. (auth)« less

  5. A novel visually CO2 controlled alveolar breath sampling technique.

    PubMed

    Birken, Thomas; Schubert, Jochen; Miekisch, Wolfram; Nöldge-Schomburg, Gabriele

    2006-01-01

    A crucial issue in the analysis of exhaled breath is the collection of gaseous samples. The analysis of pure alveolar gas is the method of choice if contamination of samples is to be minimized. Monitoring of expired CO2 can be used to identify alveolar gas. The purpose of this study was to evaluate a bed side version of this technique using visual CO2 control by means of a capnometer. 22 mechanically ventilated patients of an ICU were enrolled into the study. Alveolar and mixed expiratory gas, and arterial blood were sampled. PCO2 in blood and gas was determined in a blood gas analyzer. End tidal PCO2 was monitored in all patients by a fast responding main stream capnometry. Taking the gaseous samples was visually synchronized with the expired CO2. Alveolar CO2 contents measured during two different respiratory cycles were identical (p 0.86). The variation of the CO2 content during 10 measurements in one patient was lower than 4%. Arterial PCO2, PCO2 in alveolar gas and end tidal PCO2 showed positive correlation. The visually CO2-controlled sampling technique of alveolar gas is a reliable and reproducible method. It represents an important step in simplifying and standardizing breath analysis.

  6. Comparative effectiveness of light-microscopic techniques and PCR in detecting Thelohania solenopsae (Microsporidia) infections in red imported fire ants (Solenopsis invicta).

    PubMed

    Milks, Maynard L; Sokolova, Yuliya Y; Isakova, Irina A; Fuxa, James R; Mitchell, Forrest; Snowden, Karen F; Vinson, S Bradleigh

    2004-01-01

    The main goal of this study was to compare the effectiveness of three staining techniques (calcofluor white M2R, Giemsa and modified trichrome), and the polymerase chain reaction (PCR) in detecting the microsporidium Thelohania solenopsae in red imported fire ants (Solenopsis invicta). The effect of the number of ants in a sample on the sensitivity of the staining techniques and the PCR, and the effect of three DNA extraction protocols on the sensitivity of PCR were also examined. In the first protocol, the ants were macerated and the crude homogenate was used immediately in the PCR. In the second protocol, the homogenate was placed on a special membrane (FTA card) that traps DNA, which is subsequently used in the PCR. In the third protocol, the DNA was purified from the homogenate by traditional phenol-chloroform extraction. Except for PCR using FTA cards, the sensitivity (number of samples positive for T. solenopsae) of all detection techniques increased with the number of ants in the sample. Overall, Giemsa was the least sensitive of all detection techniques. Calcofluor was more sensitive than modified trichrome with ants from one site and was equally as sensitive as PCR with crude DNA or a FTA card with ants from both sites. Trichrome staining was equally as sensitive as PCR with a FTA card at both sites, but it was less sensitive than PCR with crude DNA at one site. PCR on FTA cards was less sensitive than PCR with crude DNA for ants from one site but not the other. There was no difference whether crude or phenol-chloroform purified DNA was used as template. In summary, the results of this study show that PCR based on a crude DNA solution is equal to or more sensitive in detecting T. solenopsae than the other detection techniques investigated, and that it can be used as a reliable diagnostic tool for screening field samples of S. invicta for T. solenopsae. Nevertheless, ant smear stained with calcofluor or modified trichrome should be used to buttress findings from PCR.

  7. Collection, transport and general processing of clinical specimens in Microbiology laboratory.

    PubMed

    Sánchez-Romero, M Isabel; García-Lechuz Moya, Juan Manuel; González López, Juan José; Orta Mira, Nieves

    2018-02-06

    The interpretation and the accuracy of the microbiological results still depend to a great extent on the quality of the samples and their processing within the Microbiology laboratory. The type of specimen, the appropriate time to obtain the sample, the way of sampling, the storage and transport are critical points in the diagnostic process. The availability of new laboratory techniques for unusual pathogens, makes necessary the review and update of all the steps involved in the processing of the samples. Nowadays, the laboratory automation and the availability of rapid techniques allow the precision and turn-around time necessary to help the clinicians in the decision making. In order to be efficient, it is very important to obtain clinical information to use the best diagnostic tools. Copyright © 2018 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  8. Evaluating structural connectomics in relation to different Q-space sampling techniques.

    PubMed

    Rodrigues, Paulo; Prats-Galino, Alberto; Gallardo-Pujol, David; Villoslada, Pablo; Falcon, Carles; Prckovska, Vesna

    2013-01-01

    Brain networks are becoming forefront research in neuroscience. Network-based analysis on the functional and structural connectomes can lead to powerful imaging markers for brain diseases. However, constructing the structural connectome can be based upon different acquisition and reconstruction techniques whose information content and mutual differences has not yet been properly studied in a unified framework. The variations of the structural connectome if not properly understood can lead to dangerous conclusions when performing these type of studies. In this work we present evaluation of the structural connectome by analysing and comparing graph-based measures on real data acquired by the three most important Diffusion Weighted Imaging techniques: DTI, HARDI and DSI. We thus come to several important conclusions demonstrating that even though the different techniques demonstrate differences in the anatomy of the reconstructed fibers the respective connectomes show variations of 20%.

  9. Importance of sample preparation for molecular diagnosis of lyme borreliosis from urine.

    PubMed

    Bergmann, A R; Schmidt, B L; Derler, A-M; Aberer, E

    2002-12-01

    Urine PCR has been used for the diagnosis of Borrelia burgdorferi infection in recent years but has been abandoned because of its low sensitivity and the irreproducibility of the results. Our study aimed to analyze technical details related to sample preparation and detection methods. Crucial for a successful urine PCR were (i) avoidance of the first morning urine sample; (ii) centrifugation at 36,000 x g; and (iii) the extraction method, with only DNAzol of the seven different extraction methods used yielding positive results with patient urine specimens. Furthermore, storage of frozen urine samples at -80 degrees C reduced the sensitivity of a positive urine PCR result obtained with samples from 72 untreated erythema migrans (EM) patients from 85% in the first 3 months to <30% after more than 3 months. Bands were detected at 276 bp on ethidium bromide-stained agarose gels after amplification by a nested PCR. The specificity of bands for 32 of 33 samples was proven by hybridization with a GEN-ETI-K-DEIA kit and for a 10 further positive amplicons by sequencing. By using all of these steps to optimize the urine PCR technique, B. burgdorferi infection could be diagnosed by using urine samples from EM patients with a sensitivity (85%) substantially better than that of serological methods (50%). This improved method could be of future importance as an additional laboratory technique for the diagnosis of unclear, unrecognized borrelia infections and diseases possibly related to Lyme borreliosis.

  10. NASTRAN thermal analyzer: Theory and application including a guide to modeling engineering problems, volume 2. [sample problem library guide

    NASA Technical Reports Server (NTRS)

    Jackson, C. E., Jr.

    1977-01-01

    A sample problem library containing 20 problems covering most facets of Nastran Thermal Analyzer modeling is presented. Areas discussed include radiative interchange, arbitrary nonlinear loads, transient temperature and steady-state structural plots, temperature-dependent conductivities, simulated multi-layer insulation, and constraint techniques. The use of the major control options and important DMAP alters is demonstrated.

  11. Visualizing Antimicrobials in Bacterial Biofilms: Three-Dimensional Biochemical Imaging Using TOF-SIMS.

    PubMed

    Davies, Sarah K; Fearn, Sarah; Allsopp, Luke P; Harrison, Freya; Ware, Ecaterina; Diggle, Stephen P; Filloux, Alain; McPhail, David S; Bundy, Jacob G

    2017-01-01

    Bacterial biofilms are groups of bacteria that exist within a self-produced extracellular matrix, adhering to each other and usually to a surface. They grow on medical equipment and inserts such as catheters and are responsible for many persistent infections throughout the body, as they can have high resistance to many antimicrobials. Pseudomonas aeruginosa is an opportunistic pathogen that can cause both acute and chronic infections and is used as a model for research into biofilms. Direct biochemical methods of imaging of molecules in bacterial biofilms are of high value in gaining a better understanding of the fundamental biology of biofilms and biochemical gradients within them. Time of flight-secondary-ion mass spectrometry (TOF-SIMS) is one approach, which combines relatively high spatial resolution and sensitivity and can perform depth profiling analysis. It has been used to analyze bacterial biofilms but has not yet been used to study the distribution of antimicrobials (including antibiotics and the antimicrobial metal gallium) within biofilms. Here we compared two methods of imaging of the interior structure of P. aeruginosa in biological samples using TOF-SIMS, looking at both antimicrobials and endogenous biochemicals: cryosectioning of tissue samples and depth profiling to give pseudo-three-dimensional (pseudo-3D) images. The sample types included both simple biofilms grown on glass slides and bacteria growing in tissues in an ex vivo pig lung model. The two techniques for the 3D imaging of biofilms are potentially valuable complementary tools for analyzing bacterial infection. IMPORTANCE Modern analytical techniques are becoming increasingly important in the life sciences; imaging mass spectrometry offers the opportunity to gain unprecedented amounts of information on the distribution of chemicals in samples-both xenobiotics and endogenous compounds. In particular, simultaneous imaging of antibiotics (and other antimicrobial compounds) and bacterium-derived metabolites in complex biological samples could be very important in the future for helping to understand how sample matrices impact the survival of bacteria under antibiotic challenge. We have shown that an imaging mass spectrometric technique, TOF-SIMS, will be potentially extremely valuable for this kind of research in the future.

  12. Data Mining Methods for Recommender Systems

    NASA Astrophysics Data System (ADS)

    Amatriain, Xavier; Jaimes*, Alejandro; Oliver, Nuria; Pujol, Josep M.

    In this chapter, we give an overview of the main Data Mining techniques used in the context of Recommender Systems. We first describe common preprocessing methods such as sampling or dimensionality reduction. Next, we review the most important classification techniques, including Bayesian Networks and Support Vector Machines. We describe the k-means clustering algorithm and discuss several alternatives. We also present association rules and related algorithms for an efficient training process. In addition to introducing these techniques, we survey their uses in Recommender Systems and present cases where they have been successfully applied.

  13. Performance evaluation of laser induced breakdown spectroscopy in the measurement of liquid and solid samples

    NASA Astrophysics Data System (ADS)

    Bilge, Gonca; Sezer, Banu; Boyaci, Ismail Hakki; Eseller, Kemal Efe; Berberoglu, Halil

    2018-07-01

    Liquid analysis by using LIBS is a complicated process due to difficulties encountered during the collection of light and formation of plasma in liquid. To avoid these, some applications are performed such as aerosol formation and transforming liquid into solid state. However, performance of LIBS in liquid samples still remains a challenging issue. In this study, performance evaluation of LIBS and parameter optimizations in liquid and solid phase samples were performed. For this purpose, milk was chosen as model sample; milk powder was used as solid sample, and milk was used as liquid sample in the experiments. Different experimental setups have been constructed for each sampling technique, and optimizations were performed to determine suitable parameters such as delay time, laser energy, repetition rate and speed of rotary table for solid sampling technique, and flow rate of carrier gas for liquid sampling technique. Target element was determined as Ca, which is a critically important element in milk for determining its nutritional value and Ca addition. In optimum parameters, limit of detection (LOD), limit of quantification (LOQ) and relative standard deviation (RSD) values were calculated as 0.11%, 0.36% and 8.29% respectively for milk powders samples; while LOD, LOQ and RSD values were calculated as 0.24%, 0.81%, and 10.93% respectively for milk samples. It can be said that LIBS is an applicable method in both liquid and solid samples with suitable systems and parameters. However, liquid analysis requires much more developed systems for more accurate results.

  14. Field Methods and Sample Collection Techniques for the Surveillance of West Nile Virus in Avian Hosts.

    PubMed

    Wheeler, Sarah S; Boyce, Walter M; Reisen, William K

    2016-01-01

    Avian hosts play an important role in the spread, maintenance, and amplification of West Nile virus (WNV). Avian susceptibility to WNV varies from species to species thus surveillance efforts can focus both on birds that survive infection and those that succumb. Here we describe methods for the collection and sampling of live birds for WNV antibodies or viremia, and methods for the sampling of dead birds. Target species and study design considerations are discussed.

  15. Enhancing image contrast of carbon nanotubes on cellular background using helium ion microscope by varying helium ion fluence.

    PubMed

    Dykas, M M; Poddar, K; Yoong, S L; Viswanathan, V; Mathew, S; Patra, A; Saha, S; Pastorin, G; Venkatesan, T

    2018-01-01

    Carbon nanotubes (CNTs) have become an important nano entity for biomedical applications. Conventional methods of their imaging, often cannot be applied in biological samples due to an inadequate spatial resolution or poor contrast between the CNTs and the biological sample. Here we report a unique and effective detection method, which uses differences in conductivities of carbon nanotubes and HeLa cells. The technique involves the use of a helium ion microscope to image the sample with the surface charging artefacts created by the He + and neutralised by electron flood gun. This enables us to obtain a few nanometre resolution images of CNTs in HeLa Cells with high contrast, which was achieved by tailoring the He + fluence. Charging artefacts can be efficiently removed for conductive CNTs by a low amount of electrons, the fluence of which is not adequate to discharge the cell surface, resulting in high image contrast. Thus, this technique enables rapid detection of any conducting nano structures on insulating cellular background even in large fields of view and fine spatial resolution. The technique demonstrated has wider applications for researchers seeking enhanced contrast and high-resolution imaging of any conducting entity in a biological matrix - a commonly encountered issue of importance in drug delivery, tissue engineering and toxicological studies. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  16. Automatic transfer function generation for volume rendering of high-resolution x-ray 3D digital mammography images

    NASA Astrophysics Data System (ADS)

    Alyassin, Abdal M.

    2002-05-01

    3D Digital mammography (3DDM) is a new technology that provides high resolution X-ray breast tomographic data. Like any other tomographic medical imaging modalities, viewing a stack of tomographic images may require time especially if the images are of large matrix size. In addition, it may cause difficulty to conceptually construct 3D breast structures. Therefore, there is a need to readily visualize the data in 3D. However, one of the issues that hinder the usage of volume rendering (VR) is finding an automatic way to generate transfer functions that efficiently map the important diagnostic information in the data. We have developed a method that randomly samples the volume. Based on the mean and the standard deviation of these samples, the technique determines the lower limit and upper limit of a piecewise linear ramp transfer function. We have volume rendered several 3DDM data using this technique and compared visually the outcome with the result from a conventional automatic technique. The transfer function generated through the proposed technique provided superior VR images over the conventional technique. Furthermore, the improvement in the reproducibility of the transfer function correlated with the number of samples taken from the volume at the expense of the processing time.

  17. Performance limitations of label-free sensors in molecular diagnosis using complex samples

    NASA Astrophysics Data System (ADS)

    Varma, Manoj

    2016-03-01

    Label-free biosensors promised a paradigm involving direct detection of biomarkers from complex samples such as serum without requiring multistep sample processing typical of labelled methods such as ELISA or immunofluorescence assays. Label-free sensors have witnessed decades of development with a veritable zoo of techniques available today exploiting a multitude of physical effects. It is appropriate now to critically assess whether label-free technologies have succeeded in delivering their promise with respect to diagnostic applications, particularly, ambitious goals such as early cancer detection using serum biomarkers, which require low limits of detection (LoD). Comparison of nearly 120 limits of detection (LoD) values reported by labelled and label-free sensing approaches over a wide range of detection techniques and target molecules in serum revealed that labeled techniques achieve 2-3 orders of magnitude better LoDs. Data from experiments where labelled and label-free assays were performed simultaneously using the same assay parameters also confirm that the LoD achieved by labelled techniques is 2 to 3 orders of magnitude better than that by label-free techniques. Furthermore, label-free techniques required significant signal amplification, for e.g. using nanoparticle conjugated secondary antibodies, to achieve LoDs comparable to labelled methods substantially deviating from the original "direct detection" paradigm. This finding has important implications on the practical limits of applying label-free detection methods for molecular diagnosis.

  18. Assessment of ovarian cycles in the African elephant (Loxodonta africana) by measurement of salivary progesterone metabolites.

    PubMed

    Illera, Juan-Carlos; Silván, Gema; Cáceres, Sara; Carbonell, Maria-Dolores; Gerique, Cati; Martínez-Fernández, Leticia; Munro, Coralie; Casares, Miguel

    2014-01-01

    Monitoring ovarian cycles through hormonal analysis is important in order to improve breeding management of captive elephants, and non-invasive collection techniques are particularly interesting for this purpose. However, there are some practical difficulties in collecting proper samples, and easier and more practical methods may be an advantage for some institutions and/or some animals. This study describes the development and validation of an enzymeimmunoassay (EIA) for progestins in salivary samples of African elephants, Loxodonta africana. Weekly urinary and salivary samples from five non-pregnant elephant cows aged 7-12 years were obtained for 28 weeks and analyzed using EIA. Both techniques correlated positively (r = 0.799; P < 0.001), and the cycle characteristics obtained were identical. The results clearly show that ovarian cycles can be monitored by measuring progestins from salivary samples in the African elephant. This is a simple and non-invasive method that may be a practical alternative to other sampling methods used in the species. © 2014 Wiley Periodicals, Inc.

  19. The photocatalytic investigation of methylene blue dye with Cr doped zinc oxide nanoparticles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ray, Rajeev; Kumar, Ashavani, E-mail: ashavani@yahoo.com

    2015-08-28

    The present work reports eco-friendly and cost effective sol-gel technique for synthesis of Chromium doped ZnO nanoparticles at room temperature. In this process Zinc nitrate, Chromium nitrate were used as precursor. Structural as well as optical properties of Cr induced ZnO samples were analysed by X-ray diffraction technique (XRD), SEM, PL and UV-Visible spectroscopy (UV-Vis) respectively. XRD analysis shows that the samples have hexagonal (wurtzite) structure with no additional peak which suggests that Cr ions fit into the regular Zn sites of ZnO crystal structure. By using Scherrer’s formula for pure and Cr doped ZnO samples the average grain sizemore » was found to be 32 nm. Further band gap of pure and doped ZnO samples have been calculated by using UV-Vis spectra. The photo-catalytic degradation of methyl blue dye under UV irradiation was examined for synthesized samples. The results show that the concentration plays an important role in photo-catalytic activity.« less

  20. Extended Phase-Space Methods for Enhanced Sampling in Molecular Simulations: A Review.

    PubMed

    Fujisaki, Hiroshi; Moritsugu, Kei; Matsunaga, Yasuhiro; Morishita, Tetsuya; Maragliano, Luca

    2015-01-01

    Molecular Dynamics simulations are a powerful approach to study biomolecular conformational changes or protein-ligand, protein-protein, and protein-DNA/RNA interactions. Straightforward applications, however, are often hampered by incomplete sampling, since in a typical simulated trajectory the system will spend most of its time trapped by high energy barriers in restricted regions of the configuration space. Over the years, several techniques have been designed to overcome this problem and enhance space sampling. Here, we review a class of methods that rely on the idea of extending the set of dynamical variables of the system by adding extra ones associated to functions describing the process under study. In particular, we illustrate the Temperature Accelerated Molecular Dynamics (TAMD), Logarithmic Mean Force Dynamics (LogMFD), and Multiscale Enhanced Sampling (MSES) algorithms. We also discuss combinations with techniques for searching reaction paths. We show the advantages presented by this approach and how it allows to quickly sample important regions of the free-energy landscape via automatic exploration.

  1. Beta-glucuronidase activity in dried blood spots: Reduced technique with biochemical parameters determined.

    PubMed

    Cé, Jaqueline; Rodrigues, Melissa Tôrres; Käfer, Eduarda Tassoni; da Costa Moraes, Vitória; Coelho, Janice Carneiro

    2017-12-01

    Mucopolysaccharidoses (MPS) occur due to deficiency in the activity of enzymes that catalyze the breakdown of glycosaminoglycans. MPS VII is caused by deficiency of the beta-glucuronidase enzyme (GUSB). This study aimed to enhance the technique to measure GUSB activity by reducing the amount of reagents and the size of the DBS, as well as to determine some biochemical parameters of enzyme of healthy individuals. The measurement of GUSB in 3 and 1.2mm DBS (with reagents reduced 2.5- and fourfold) was correlated and the precision of the technique was tested. Optimal pH, Km and Vmax, and thermostability parameters were determined and time and temperature of sample storage were established. The correlations among the techniques were significant. Although the correlation coefficient was similar, fourfold reduction was selected. pH4.4 had the highest enzyme activity. GUSB's Km was 1.25mM, while Vmax was 594.48nmol/h/mL. After pre-incubation of the sample at 60°C, its activity dropped from 100% to 15.8% at 120min. GUSB activity significantly decreased after 45days of storage at 4, 25, and 37°C. This research allowed a previously described technique for MPS VII diagnosis to be adapted for smaller amounts of sample and reagents. That will facilitate the use of smaller amounts of samples, which may be used for other techniques and to save material. Given the importance of early MPS VII diagnosis due to the severity of the disease, using reliable diagnostic techniques in DBS is essential. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. Ultrasonic technique for measuring porosity of plasma-sprayed alumina coatings

    NASA Astrophysics Data System (ADS)

    Parthasarathi, S.; Tittmann, B. R.; Onesto, E. J.

    1997-12-01

    Porosity is an important factor in plasma-sprayed coatings, especially ceramic coatings. Excessive poros-ity can adversely affect the performance of the coated component in various ways. An ultrasonic nonde-structive measurement technique has been developed to measure porosity in plasma-sprayed alumina coatings. The technique is generic and can be extended to other ceramic coating systems. To test the tech-nique, freestanding alumina coatings with varying levels of porosity were fabricated via plasma spray. Samples with varying porosity, obtained through innovative fabrication techniques, were used to gener-ate a calibration curve. The ultrasonic velocity in the low-frequency range was found to be dependent on the density of freestanding coatings (measured via Archimedian techniques). This dependence is the basis of the development of a technique to measure the density of coatings.

  3. Monitoring systems for community water supplies

    NASA Technical Reports Server (NTRS)

    Taylor, R. E.; Brooks, R. R.; Jeffers, E. L.; Linton, A. T.; Poel, G. D.

    1978-01-01

    Water monitoring system includes equipment and techniques for waste water sampling sensors for determining levels of microorganisms, oxygen, chlorine, and many other important parameters. System includes data acquisition and display system that allows computation of water quality information for real time display.

  4. Recent advances in stable isotope labeling based techniques for proteome relative quantification.

    PubMed

    Zhou, Yuan; Shan, Yichu; Zhang, Lihua; Zhang, Yukui

    2014-10-24

    The large scale relative quantification of all proteins expressed in biological samples under different states is of great importance for discovering proteins with important biological functions, as well as screening disease related biomarkers and drug targets. Therefore, the accurate quantification of proteins at proteome level has become one of the key issues in protein science. Herein, the recent advances in stable isotope labeling based techniques for proteome relative quantification were reviewed, from the aspects of metabolic labeling, chemical labeling and enzyme-catalyzed labeling. Furthermore, the future research direction in this field was prospected. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Diagnostic use of 3 techniques for identification of microsporidian spores among AIDS patients in Portugal.

    PubMed

    Matos, Olga; Lobo, Maria L; Gonçalves, Luzia; Antunes, Francisco

    2002-01-01

    The calcofluor stain (CF), the monoclonal antibody (MAb) 3B6 indirect immunofluorescence assay (IFA) and the modified trichrome blue stain (MT) were compared in terms of their reproducibility in a routine laboratory and in order to evaluate the percentage of cases of microsporidiosis in Portuguese HIV patients. A total of 166 faeces samples, 71 pulmonary specimens and 43 urine samples were studied using the 3 techniques. CF had a high sensitivity and a moderate specificity when applied to faeces samples. The sensitivity was lower with pulmonary specimens. The method is easy and quick to perform but readings take a long time to obtain. The MAb 3B6 IFA had a good to excellent sensitivity when applied to faeces and urine samples, but moderate sensitivity in pulmonary specimens. Readings were quick and easy to obtain, but the assay took longer to perform than the other 2 techniques. There was a greater correlation between the results obtained with the MT and MAb 3B6 IFA techniques than between those obtained with the MT and CF techniques. In conclusion, the MT performed better than the MAb 3B6 IFA and CF and continues to have an important place in a routine laboratory for the diagnosis of microsporidiosis. This work also confirms the existence of a relatively high proportion (30%) of cases of infection with Microsporidia, especially intestinal microsporidiosis, in HIV patients in Portugal.

  6. Grazing-incidence coherent x-ray imaging in true reflection geometry

    NASA Astrophysics Data System (ADS)

    Sun, Tao; Jiang, Zhang; Strzalka, Joseph; Wang, Jin

    2012-02-01

    The development of the 3^rd and 4^th generation synchrotrons has stimulated extensive research activities in x-ray imaging techniques. Among all, coherent diffractive imaging (CDI) shows great promise, as its resolution is only limited by the wavelength of the source. Most of the CDI work reported thus far used transmission geometry, which however is not suitable for samples on opaque substrates or in which only the surfaces are the regions of interest. Even though two groups have performed CDI experiments (using laser or x-ray) in reflection geometry and succeeded in reconstructing the planar image of the surface, the theoretical underpinnings and analysis approaches of their techniques are essentially identical to transmission CDI. Most importantly, they couldn't obtain the structural information along sample thickness direction. Here, we introduce a reflection CDI technique that works at grazing-incidence geometry. By visualizing Au nanostructures fabricated on Si substrate, we demonstrate that this innovative imaging technique is capable of obtaining both 2D and 3D information of surfaces or buried structures in the samples. In the meanwhile, we will also explain the grazing-incidence-scattering based-algorithm developed for 3D phase retrieval.

  7. Evaluation and recommendation of sensitivity analysis methods for application to Stochastic Human Exposure and Dose Simulation models.

    PubMed

    Mokhtari, Amirhossein; Christopher Frey, H; Zheng, Junyu

    2006-11-01

    Sensitivity analyses of exposure or risk models can help identify the most significant factors to aid in risk management or to prioritize additional research to reduce uncertainty in the estimates. However, sensitivity analysis is challenged by non-linearity, interactions between inputs, and multiple days or time scales. Selected sensitivity analysis methods are evaluated with respect to their applicability to human exposure models with such features using a testbed. The testbed is a simplified version of a US Environmental Protection Agency's Stochastic Human Exposure and Dose Simulation (SHEDS) model. The methods evaluated include the Pearson and Spearman correlation, sample and rank regression, analysis of variance, Fourier amplitude sensitivity test (FAST), and Sobol's method. The first five methods are known as "sampling-based" techniques, wheras the latter two methods are known as "variance-based" techniques. The main objective of the test cases was to identify the main and total contributions of individual inputs to the output variance. Sobol's method and FAST directly quantified these measures of sensitivity. Results show that sensitivity of an input typically changed when evaluated under different time scales (e.g., daily versus monthly). All methods provided similar insights regarding less important inputs; however, Sobol's method and FAST provided more robust insights with respect to sensitivity of important inputs compared to the sampling-based techniques. Thus, the sampling-based methods can be used in a screening step to identify unimportant inputs, followed by application of more computationally intensive refined methods to a smaller set of inputs. The implications of time variation in sensitivity results for risk management are briefly discussed.

  8. Recommendations for level-determined sampling in wells

    NASA Astrophysics Data System (ADS)

    Lerner, David N.; Teutsch, Georg

    1995-10-01

    Level-determined samples of groundwater are increasingly important for hydrogeological studies. The techniques for collecting them range from the use of purpose drilled wells, sometimes with sophisticated dedicated multi-level samplers in them, to a variety of methods used in open wells. Open, often existing, wells are frequently used on cost grounds, but there are risks of obtaining poor and unrepresentative samples. Alternative approaches to level-determined sampling incorporate seven concepts: depth sampling; packer systems; individual wells; dedicated multi-level systems; separation pumping; baffle systems; multi-port sock samplers. These are outlined and evaluated in terms of the environment to be sampled, and the features and performance of the methods. Recommendations are offered to match methods to sampling problems.

  9. Trap Type, Chirality of a-Pinene, and Geographic Region Affect Sampling Efficiency of Root and Lower Stem Insects in Pine

    Treesearch

    Nadir Erbilgin; Alex Szele; Kier Dean Klepzig; Kenneth Francis Raffa

    2001-01-01

    Root and lower stem insects cause significant damage to conifers, vector phytopathogenic fungi, and can predispose trees to bark beetle attacks. The development of effective sampling techniques is an important component in managing these cryptic insects. We tested the effects of trap type and stereochemistry of a-pinene, in combination with ethanol, on catches of the...

  10. The experience sampling method: Investigating students' affective experience

    NASA Astrophysics Data System (ADS)

    Nissen, Jayson M.; Stetzer, MacKenzie R.; Shemwell, Jonathan T.

    2013-01-01

    Improving non-cognitive outcomes such as attitudes, efficacy, and persistence in physics courses is an important goal of physics education. This investigation implemented an in-the-moment surveying technique called the Experience Sampling Method (ESM) [1] to measure students' affective experience in physics. Measurements included: self-efficacy, cognitive efficiency, activation, intrinsic motivation, and affect. Data are presented that show contrasts in students' experiences (e.g., in physics vs. non-physics courses).

  11. Free-Flow Open-Chamber Electrophoresis

    NASA Technical Reports Server (NTRS)

    Sharnez, Rizwan; Sammons, David W.

    1994-01-01

    Free-flow open-chamber electrophoresis variant of free-flow electrophoresis performed in chamber with open ends and in which velocity of electro-osmotic flow adjusted equal to and opposite mean electrophoretic velocity of sample. Particles having electrophoretic mobilities greater than mean mobility of sample particles move toward cathode, those with mobilities less move toward anode. Technique applied to separation of components of mixtures of biologically important substances. Sensitivity enhanced by use of tapered chamber.

  12. Characterizing porosity of selected Early Palaeozoic shales from the Baltic Basin: organic petrology, gas adsorption and WIP and KIP approach.

    NASA Astrophysics Data System (ADS)

    Słomski, Piotr; Mastalerz, Maria; Szczepański, Jacek; Derkowski, Arkadiusz; Topór, Tomasz

    2017-04-01

    The porosity in the selected Ordovician and Silurian mudstones from the Baltic Basin collected from three wells (W1, M1, B1 and O3) was examined in a suite of 78 samples representing the Kopalino, Sasino, Prabuty, Pasłęk (including Jantar Member) and Pelplin Formations. Organic petrology, mineral composition along with N2 low-pressure adsorption (NLPA), water and kerosene immersion porosimetry (WIP and KIP, respectively) as well as image analysis techniques were used to determine pore volumes, pore sizes and pore-size distributions and to evaluate factors controlling porosity. The majority of the investigated samples represent argillaceous mudstones. Only a few samples from O3 and W1 are different lithologically and represent siliceous-argillaceous, calcareous, or calcareous-argillicaous mudstones. The samples are characterized by total organic carbon (TOC) content ranging from 0.13 to 7.20 wt. % and vitrinite reflectance (Ro) ranging from 1.02 to 1.22%, indicating late mature rocks within condensate - wet gas window. Total porosity measured using WIP is in the range from 4.6 % to 10 %, while KIP gave values from 1.5 % to 8.9 %. NLPA technique on the 75 µm size fraction revealed that mesopores area is in the range from 10.59 to 34.34 m2/g, while mesopores volume ranges from 0.024 to 0.062 cm3/g. Correlation between mesopores surface area and Ro is weak, but in general the surface area of mesopores is the largest in the least mature samples. Moreover, as indicated by gas adsorption data, both pores greater than 30 nm and smaller than 4 nm are important contributors to the total mesoporess surface area. In general, rather weak correlation between different mudstone constituents (including kerogen types) and porosity measured by means of various techniques (WIP, KIP and NLPA) reveal that there is no single factor controlling porosity in the investigated suite of samples. This conclusion is also confirmed by image analysis performed on large-scale high-resolution BSE images for selected representative samples. However, for mesopores, the dominant contribution comes from organic matter for the Jantar, Prabuty and Sasino Formations, as indicated by NLPA technique. Furthermore, importance of clay minerals for macropore volume is indicated by WIP and KIP technique. Acknowledgments: the study was supported from grant SHALESEQ (No PL12-0109) and SHALEMECH (No BG2/ShaleMech/14) funded by the National Centre for Research and Development.

  13. Compositional transformations in ion implanted polymers

    NASA Astrophysics Data System (ADS)

    Abdul-Kader, A. M.; Turos, A.; Grambole, D.; Jagielski, J.; Piątkowska, A.; Madi, N. K.; Al-Maadeed, M.

    2005-10-01

    Changes of surface layer composition produced by ion bombardment of polyethylene and polypropylene samples were studied. These materials are under consideration for load bearing surfaces in biological and technical applications. To improve their tribological properties, surface layers are usually modified by ionizing radiation. Therefore, to study the mechanism of transformations induced by ion beam bombardment selected polymers were implanted with H, He and Ar ions to the fluences ranging from 1 × 1013 to 2 × 1016/cm2. RBS and NRA techniques were applied for sample analysis. Important hydrogen release was observed with increasing ion dose and was correlated with the ion stopping power. Another important effect observed was the rapid oxidation of samples, which apparently occurs after exposure of implanted samples to the air. Up to 10 at.% of oxygen can be incorporated in the implanted layer.

  14. Prevalence of canine heartworm (Dirofilaria immitis) disease in dogs of central Portugal

    PubMed Central

    Vieira, Ana Luísa; Vieira, Maria João; Oliveira, João Manuel; Simões, Ana Rita; Diez-Baños, Pablo; Gestal, Juan

    2014-01-01

    The aim of the present study was to determine the prevalence and risk factors concerning Dirofilaria immitis infection in dogs from Figueira da Foz, located in the central region of Portugal. In the period between November 2009 and January 2011, 304 blood samples were obtained from dogs over 1 year of age, with no previous history of heartworm prevention or diagnosis. Every blood sample was analyzed using varied laboratory techniques (direct microscopic evaluation of a fresh blood sample, the modified Knott technique, and the ELISA antigen detection test – IDEXX Snapp®). In the samples in which microfilaremia was detected, a histochemical technique using acid phosphatase staining was applied to identify the species of microfilariae. A total prevalence of 27.3% (83 out of 304) was found. We also found that 73.5% of all positive cases (61 out of 83) were microfilaremic, and 26.5% were occult infections (22 out of 83). By means of a histochemical technique Dirofilaria immitis was identified in 96.7% of microfilaremic samples. A multivariate model allowed us to identify the following risk factors for the presence of heartworm disease: age between 4 and 9 years, dogs living in a rural environment, large breed dogs, and living outdoors. This study shows for the first time the high prevalence of heartworm disease in a central area of Portugal and emphasizes the importance of systematic screening for this disease, as well as the need to prevent it in dogs in this area. PMID:24534524

  15. ALTERNATIVE TECHNIQUES FOR MEASUREMENT OF PERCHLORATE IN FERTILIZER AND ENVIRONMENTAL SAMPLES

    EPA Science Inventory

    The Perchlorate anion has been implicated as a potentially serious environmental pollutant, being found in drinking water and irrigated crops. Commercial fertilizers have recently been shown to contain high levels of Perchlorate impurities and thus be potentially important source...

  16. Development of EPA OTM 10 for Landfill Applications, Interim Report

    EPA Science Inventory

    Quantification of greenhouse gas emissions from area sources is of increasing importance. Due to the spatial extent and non homogenous nature of many area sources, assessment of fugitive emissions using traditional point sampling techniques can be problematic. To address this, th...

  17. Techniques for avoiding discrimination errors in the dynamic sampling of condensable vapors

    NASA Technical Reports Server (NTRS)

    Lincoln, K. A.

    1983-01-01

    In the mass spectrometric sampling of dynamic systems, measurements of the relative concentrations of condensable and noncondensable vapors can be significantly distorted if some subtle, but important, instrumental factors are overlooked. Even with in situ measurements, the condensables are readily lost to the container walls, and the noncondensables can persist within the vacuum chamber and yield a disproportionately high output signal. Where single pulses of vapor are sampled this source of error is avoided by gating either the mass spectrometer ""on'' or the data acquisition instrumentation ""on'' only during the very brief time-window when the initial vapor cloud emanating directly from the vapor source passes through the ionizer. Instrumentation for these techniques is detailed and its effectiveness is demonstrated by comparing gated and nongated spectra obtained from the pulsed-laser vaporization of several materials.

  18. Recent Application of Solid Phase Based Techniques for Extraction and Preconcentration of Cyanotoxins in Environmental Matrices.

    PubMed

    Mashile, Geaneth Pertunia; Nomngongo, Philiswa N

    2017-03-04

    Cyanotoxins are toxic and are found in eutrophic, municipal, and residential water supplies. For this reason, their occurrence in drinking water systems has become a global concern. Therefore, monitoring, control, risk assessment, and prevention of these contaminants in the environmental bodies are important subjects associated with public health. Thus, rapid, sensitive, selective, simple, and accurate analytical methods for the identification and determination of cyanotoxins are required. In this paper, the sampling methodologies and applications of solid phase-based sample preparation methods for the determination of cyanotoxins in environmental matrices are reviewed. The sample preparation techniques mainly include solid phase micro-extraction (SPME), solid phase extraction (SPE), and solid phase adsorption toxin tracking technology (SPATT). In addition, advantages and disadvantages and future prospects of these methods have been discussed.

  19. Importance sampling variance reduction for the Fokker–Planck rarefied gas particle method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Collyer, B.S., E-mail: benjamin.collyer@gmail.com; London Mathematical Laboratory, 14 Buckingham Street, London WC2N 6DF; Connaughton, C.

    The Fokker–Planck approximation to the Boltzmann equation, solved numerically by stochastic particle schemes, is used to provide estimates for rarefied gas flows. This paper presents a variance reduction technique for a stochastic particle method that is able to greatly reduce the uncertainty of the estimated flow fields when the characteristic speed of the flow is small in comparison to the thermal velocity of the gas. The method relies on importance sampling, requiring minimal changes to the basic stochastic particle scheme. We test the importance sampling scheme on a homogeneous relaxation, planar Couette flow and a lid-driven-cavity flow, and find thatmore » our method is able to greatly reduce the noise of estimated quantities. Significantly, we find that as the characteristic speed of the flow decreases, the variance of the noisy estimators becomes independent of the characteristic speed.« less

  20. Studies of the micromorphology of sputtered TiN thin films by autocorrelation techniques

    NASA Astrophysics Data System (ADS)

    Smagoń, Kamil; Stach, Sebastian; Ţălu, Ştefan; Arman, Ali; Achour, Amine; Luna, Carlos; Ghobadi, Nader; Mardani, Mohsen; Hafezi, Fatemeh; Ahmadpourian, Azin; Ganji, Mohsen; Grayeli Korpi, Alireza

    2017-12-01

    Autocorrelation techniques are crucial tools for the study of the micromorphology of surfaces: They provide the description of anisotropic properties and the identification of repeated patterns on the surface, facilitating the comparison of samples. In the present investigation, some fundamental concepts of these techniques including the autocorrelation function and autocorrelation length have been reviewed and applied in the study of titanium nitride thin films by atomic force microscopy (AFM). The studied samples were grown on glass substrates by reactive magnetron sputtering at different substrate temperatures (from 25 {}°C to 400 {}°C , and their micromorphology was studied by AFM. The obtained AFM data were analyzed using MountainsMap Premium software obtaining the correlation function, the structure of isotropy and the spatial parameters according to ISO 25178 and EUR 15178N. These studies indicated that the substrate temperature during the deposition process is an important parameter to modify the micromorphology of sputtered TiN thin films and to find optimized surface properties. For instance, the autocorrelation length exhibited a maximum value for the sample prepared at a substrate temperature of 300 {}°C , and the sample obtained at 400 {}°C presented a maximum angle of the direction of the surface structure.

  1. Solid-Phase Extraction (SPE): Principles and Applications in Food Samples.

    PubMed

    Ötles, Semih; Kartal, Canan

    2016-01-01

    Solid-Phase Extraction (SPE) is a sample preparation method that is practised on numerous application fields due to its many advantages compared to other traditional methods. SPE was invented as an alternative to liquid/liquid extraction and eliminated multiple disadvantages, such as usage of large amount of solvent, extended operation time/procedure steps, potential sources of error, and high cost. Moreover, SPE can be plied to the samples combined with other analytical methods and sample preparation techniques optionally. SPE technique is a useful tool for many purposes through its versatility. Isolation, concentration, purification and clean-up are the main approaches in the practices of this method. Food structures represent a complicated matrix and can be formed into different physical stages, such as solid, viscous or liquid. Therefore, sample preparation step particularly has an important role for the determination of specific compounds in foods. SPE offers many opportunities not only for analysis of a large diversity of food samples but also for optimization and advances. This review aims to provide a comprehensive overview on basic principles of SPE and its applications for many analytes in food matrix.

  2. Study of Bacterial Samples Using Laser Induced Breakdown Spectroscopy

    NASA Astrophysics Data System (ADS)

    W, A. Farooq; M, Atif; W, Tawfik; M, S. Alsalhi; Z, A. Alahmed; M, Sarfraz; J, P. Singh

    2014-12-01

    Laser-induced breakdown spectroscopy (LIBS) technique has been applied to investigate two different types of bacteria, Escherichia coli (B1) and Micrococcus luteus (B2) deposited on glass slides using Spectrolaser 7000. LIBS spectra were analyzed using spectrolaser software. LIBS spectrum of glass substrate was compared with bacteria spectra. Ca, Mg, Na, K, P, S, Cl, Fe, Al, Mn, Cu, C, H and CN-band appeared in bacterial samples in air. Two carbon lines at 193.02 nm, 247.88 nm and one hydrogen line at 656.28 nm with intensity ratios of 1.9, 1.83 and 1.53 appeared in bacterial samples B1 and B2 respectively. Carbon and hydrogen are the important components of the bio-samples like bacteria and other cancer cells. Investigation on LIBS spectra of the samples in He and Ar atmospheres is also presented. Ni lines appeared only in B2 sample in Ar atmosphere. From the present experimental results we are able to show that LIBS technique has a potential in the identification and discrimination of different types of bacteria.

  3. A study on Improvisation in a Musical performance using Multifractal Detrended Cross Correlation Analysis

    NASA Astrophysics Data System (ADS)

    Sanyal, Shankha; Banerjee, Archi; Patranabis, Anirban; Banerjee, Kaushik; Sengupta, Ranjan; Ghosh, Dipak

    2016-11-01

    MFDFA (the most rigorous technique to assess multifractality) was performed on four Hindustani music samples played on same 'raga' sung by the same performer. Each music sample was divided into six parts and 'multifractal spectral width' was determined for each part corresponding to the four samples. The results obtained reveal that different parts of all the four sound signals possess spectral width of widely varying values. This gives a cue of the so called 'musical improvisation' in all music samples, keeping in mind they belong to the bandish part of the same raga. Formal compositions in Hindustani raga are juxtaposed with the improvised portions, where an artist manoeuvers his/her own creativity to bring out a mood that is specific for that particular performance, which is known as 'improvisation'. Further, this observation hints at the association of different emotions even in the same bandish of the same raga performed by the same artist, this interesting observation cannot be revealed unless rigorous non-linear technique explores the nature of musical structure. In the second part, we applied MFDXA technique to explore more in-depth about 'improvisation' and association with emotion. This technique is applied to find the degree of cross-correlation (γx) between the different parts of the samples. Pronounced correlation has been observed in the middle parts of the all the four samples evident from higher values of γx ​whereas the other parts show weak correlation. This gets further support from the values of spectral width from different parts of the sample - width of those parts is significantly different from other parts. This observation is extremely new both in respect of musical structure of so called improvisation and associated emotion. The importance of this study in application area of cognitive music therapy is immense.

  4. Development of Novel Method for Rapid Extract of Radionuclides from Solution Using Polymer Ligand Film

    NASA Astrophysics Data System (ADS)

    Rim, Jung H.

    Accurate and fast determination of the activity of radionuclides in a sample is critical for nuclear forensics and emergency response. Radioanalytical techniques are well established for radionuclides measurement, however, they are slow and labor intensive, requiring extensive radiochemical separations and purification prior to analysis. With these limitations of current methods, there is great interest for a new technique to rapidly process samples. This dissertation describes a new analyte extraction medium called Polymer Ligand Film (PLF) developed to rapidly extract radionuclides. Polymer Ligand Film is a polymer medium with ligands incorporated in its matrix that selectively and rapidly extract analytes from a solution. The main focus of the new technique is to shorten and simplify the procedure necessary to chemically isolate radionuclides for determination by alpha spectrometry or beta counting. Five different ligands were tested for plutonium extraction: bis(2-ethylhexyl) methanediphosphonic acid (H2DEH[MDP]), di(2-ethyl hexyl) phosphoric acid (HDEHP), trialkyl methylammonium chloride (Aliquat-336), 4,4'(5')-di-t-butylcyclohexano 18-crown-6 (DtBuCH18C6), and 2-ethylhexyl 2-ethylhexylphosphonic acid (HEH[EHP]). The ligands that were effective for plutonium extraction further studied for uranium extraction. The plutonium recovery by PLFs has shown dependency on nitric acid concentration and ligand to total mass ratio. H2DEH[MDP] PLFs performed best with 1:10 and 1:20 ratio PLFs. 50.44% and 47.61% of plutonium were extracted on the surface of PLFs with 1M nitric acid for 1:10 and 1:20 PLF, respectively. HDEHP PLF provided the best combination of alpha spectroscopy resolution and plutonium recovery with 1:5 PLF when used with 0.1M nitric acid. The overall analyte recovery was lower than electrodeposited samples, which typically has recovery above 80%. However, PLF is designed to be a rapid field deployable screening technique and consistency is more important than recovery. PLFs were also tested using blind quality control samples and the activities were accurately measured. It is important to point out that PLFs were consistently susceptible to analytes penetrating and depositing below the surface. The internal radiation within the body of PLF is mostly contained and did not cause excessive self-attenuation and peak broadening in alpha spectroscopy. The analyte penetration issue was beneficial in the destructive analysis. H2DEH[MDP] PLF was tested with environmental samples to fully understand the capabilities and limitations of the PLF in relevant environments. The extraction system was very effective in extracting plutonium from environmental water collected from Mortandad Canyon at Los Alamos National Laboratory with minimal sample processing. Soil samples were tougher to process than the water samples. Analytes were first leached from the soil matrixes using nitric acid before processing with PLF. This approach had a limitation in extracting plutonium using PLF. The soil samples from Mortandad Canyon, which are about 1% iron by weight, were effectively processed with the PLF system. Even with certain limitations of the PLF extraction system, this technique was able to considerably decrease the sample analysis time. The entire environmental sample was analyzed within one to two days. The decrease in time can be attributed to the fact that PLF is replacing column chromatography and electrodeposition with a single step for preparing alpha spectrometry samples. The two-step process of column chromatography and electrodeposition takes a couple days to a week to complete depending on the sample. The decrease in time and the simplified procedure make this technique a unique solution for application to nuclear forensics and emergency response. A large number of samples can be quickly analyzed and selective samples can be further analyzed with more sensitive techniques based on the initial data. The deployment of a PLF system as a screening method will greatly reduce a total analysis time required to gain meaningful isotopic data for the nuclear forensics application. (Abstract shortened by UMI.)

  5. Interpretation of Blood Microbiology Results - Function of the Clinical Microbiologist.

    PubMed

    Kristóf, Katalin; Pongrácz, Júlia

    2016-04-01

    The proper use and interpretation of blood microbiology results may be one of the most challenging and one of the most important functions of clinical microbiology laboratories. Effective implementation of this function requires careful consideration of specimen collection and processing, pathogen detection techniques, and prompt and precise reporting of identification and susceptibility results. The responsibility of the treating physician is proper formulation of the analytical request and to provide the laboratory with complete and precise patient information, which are inevitable prerequisites of a proper testing and interpretation. The clinical microbiologist can offer advice concerning the differential diagnosis, sampling techniques and detection methods to facilitate diagnosis. Rapid detection methods are essential, since the sooner a pathogen is detected, the better chance the patient has of getting cured. Besides the gold-standard blood culture technique, microbiologic methods that decrease the time in obtaining a relevant result are more and more utilized today. In the case of certain pathogens, the pathogen can be identified directly from the blood culture bottle after propagation with serological or automated/semi-automated systems or molecular methods or with MALDI-TOF MS (matrix-assisted laser desorption-ionization time of flight mass spectrometry). Molecular biology methods are also suitable for the rapid detection and identification of pathogens from aseptically collected blood samples. Another important duty of the microbiology laboratory is to notify the treating physician immediately about all relevant information if a positive sample is detected. The clinical microbiologist may provide important guidance regarding the clinical significance of blood isolates, since one-third to one-half of blood culture isolates are contaminants or isolates of unknown clinical significance. To fully exploit the benefits of blood culture and other (non- culture based) diagnoses, the microbiologist and the clinician should interact directly.

  6. Relative importance index (RII) in ranking of procrastination factors among university students

    NASA Astrophysics Data System (ADS)

    Aziz, Nazrina; Zain, Zakiyah; Mafuzi, Raja Muhammad Zahid Raja; Mustapa, Aini Mastura; Najib, Nur Hasibah Mohd; Lah, Nik Fatihah Nik

    2016-08-01

    Procrastination is the action of delaying or postponing something such as making a decision or starting or completing some tasks or activities. According to previous studies, students who have a strong tendency to procrastinate get low scores in their tests, resulting in poorer academic performance compared to those who do not procrastinate. This study aims to identify the procrastination factors in completing assignments among three groups of undergraduate students. The relative importance of procrastination factors was quantified by the relative importance index (RII) method prior to ranking. A multistage sampling technique was used in selecting the sample. The findings revealed that `too many works in one time' is one of the top three factors contributing to procrastination in all groups.

  7. Navigating complex sample analysis using national survey data.

    PubMed

    Saylor, Jennifer; Friedmann, Erika; Lee, Hyeon Joo

    2012-01-01

    The National Center for Health Statistics conducts the National Health and Nutrition Examination Survey and other national surveys with probability-based complex sample designs. Goals of national surveys are to provide valid data for the population of the United States. Analyses of data from population surveys present unique challenges in the research process but are valuable avenues to study the health of the United States population. The aim of this study was to demonstrate the importance of using complex data analysis techniques for data obtained with complex multistage sampling design and provide an example of analysis using the SPSS Complex Samples procedure. Illustration of challenges and solutions specific to secondary data analysis of national databases are described using the National Health and Nutrition Examination Survey as the exemplar. Oversampling of small or sensitive groups provides necessary estimates of variability within small groups. Use of weights without complex samples accurately estimates population means and frequency from the sample after accounting for over- or undersampling of specific groups. Weighting alone leads to inappropriate population estimates of variability, because they are computed as if the measures were from the entire population rather than a sample in the data set. The SPSS Complex Samples procedure allows inclusion of all sampling design elements, stratification, clusters, and weights. Use of national data sets allows use of extensive, expensive, and well-documented survey data for exploratory questions but limits analysis to those variables included in the data set. The large sample permits examination of multiple predictors and interactive relationships. Merging data files, availability of data in several waves of surveys, and complex sampling are techniques used to provide a representative sample but present unique challenges. In sophisticated data analysis techniques, use of these data is optimized.

  8. Predictors of community therapists' use of therapy techniques in a large public mental health system.

    PubMed

    Beidas, Rinad S; Marcus, Steven; Aarons, Gregory A; Hoagwood, Kimberly E; Schoenwald, Sonja; Evans, Arthur C; Hurford, Matthew O; Hadley, Trevor; Barg, Frances K; Walsh, Lucia M; Adams, Danielle R; Mandell, David S

    2015-04-01

    Few studies have examined the effects of individual and organizational characteristics on the use of evidence-based practices in mental health care. Improved understanding of these factors could guide future implementation efforts to ensure effective adoption, implementation, and sustainment of evidence-based practices. To estimate the relative contribution of individual and organizational factors on therapist self-reported use of cognitive-behavioral, family, and psychodynamic therapy techniques within the context of a large-scale effort to increase use of evidence-based practices in an urban public mental health system serving youth and families. In this observational, cross-sectional study of 23 organizations, data were collected from March 1 through July 25, 2013. We used purposive sampling to recruit the 29 largest child-serving agencies, which together serve approximately 80% of youth receiving publically funded mental health care. The final sample included 19 agencies with 23 sites, 130 therapists, 36 supervisors, and 22 executive administrators. Therapist self-reported use of cognitive-behavioral, family, and psychodynamic therapy techniques, as measured by the Therapist Procedures Checklist-Family Revised. Individual factors accounted for the following percentages of the overall variation: cognitive-behavioral therapy techniques, 16%; family therapy techniques, 7%; and psychodynamic therapy techniques, 20%. Organizational factors accounted for the following percentages of the overall variation: cognitive-behavioral therapy techniques, 23%; family therapy techniques, 19%; and psychodynamic therapy techniques, 7%. Older therapists and therapists with more open attitudes were more likely to endorse use of cognitive-behavioral therapy techniques, as were those in organizations that had spent fewer years participating in evidence-based practice initiatives, had more resistant cultures, and had more functional climates. Women were more likely to endorse use of family therapy techniques, as were those in organizations employing more fee-for-service staff and with more stressful climates. Therapists with more divergent attitudes and less knowledge about evidence-based practices were more likely to use psychodynamic therapy techniques. This study suggests that individual and organizational factors are important in explaining therapist behavior and use of evidence-based practices, but the relative importance varies by therapeutic technique.

  9. Spatial Modeling of Geometallurgical Properties: Techniques and a Case Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deutsch, Jared L., E-mail: jdeutsch@ualberta.ca; Palmer, Kevin; Deutsch, Clayton V.

    High-resolution spatial numerical models of metallurgical properties constrained by geological controls and more extensively by measured grade and geomechanical properties constitute an important part of geometallurgy. Geostatistical and other numerical techniques are adapted and developed to construct these high-resolution models accounting for all available data. Important issues that must be addressed include unequal sampling of the metallurgical properties versus grade assays, measurements at different scale, and complex nonlinear averaging of many metallurgical parameters. This paper establishes techniques to address each of these issues with the required implementation details and also demonstrates geometallurgical mineral deposit characterization for a copper–molybdenum deposit inmore » South America. High-resolution models of grades and comminution indices are constructed, checked, and are rigorously validated. The workflow demonstrated in this case study is applicable to many other deposit types.« less

  10. Filter paper-assisted cell transfer (FaCT) technique: A novel cell-sampling technique for intraoperative diagnosis of central nervous system tumors.

    PubMed

    Kawamura, Jumpei; Kamoshida, Shingo; Shimakata, Takaaki; Hayashi, Yurie; Sakamaki, Kuniko; Denda, Tamami; Kawai, Kenji; Kuwao, Sadahito

    2017-04-01

    Intraoperative diagnosis of central nervous system (CNS) tumors provides critical guidance to surgeons in the determination of surgical resection margins and treatment. The techniques and preparations used for the intraoperative diagnosis of CNS tumors include frozen sectioning and cytologic methods (squash smear and touch imprint). Cytologic specimens, which do not have freezing artifacts, are important as an adjuvant tool to frozen sections. However, if the amount of submitted tissue samples is limited, then it is difficult to prepare both frozen sections and squash smears or touch imprint specimens from a single sample at the same time. Therefore, the objective of this study was to derive cells directly from filter paper on which tumor samples are placed. The authors established the filter paper-assisted cell transfer (FaCT) smear technique, in which tumor cells are transferred onto a glass slide directly from the filter paper sample spot after the biopsy is removed. Cell yields and diagnostic accuracy of the FaCT smears were assessed in 40 CNS tumors. FaCT smears had ample cell numbers and well preserved cell morphology sufficient for cytologic diagnosis, even if the submitted tissues were minimal. The overall diagnostic concordance rates between frozen sections and FaCT smears were 90% and 87.5%, respectively (no significant differences). When combining FaCT smears with frozen sections, the diagnostic concordance rate rose to 92.5%. The current results suggest that the FaCT smear technique is a simple and effective processing method that has significant value for intraoperative diagnosis of CNS tumors. Cancer Cytopathol 2017;125:277-282. © 2016 American Cancer Society. © 2017 American Cancer Society.

  11. Accuracy evaluation of an X-ray microtomography system.

    PubMed

    Fernandes, Jaquiel S; Appoloni, Carlos R; Fernandes, Celso P

    2016-06-01

    Microstructural parameter evaluation of reservoir rocks is of great importance to petroleum production companies. In this connection, X-ray computed microtomography (μ-CT) has proven to be a quite useful method for the assessment of rocks, as it provides important microstructural parameters, such as porosity, permeability, pore size distribution and porous phase of the sample. X-ray computed microtomography is a non-destructive technique that enables the reuse of samples already measured and also yields 2-D cross-sectional images of the sample as well as volume rendering. This technique offers an additional advantage, as it does not require sample preparation, of reducing the measurement time, which is approximately one to three hours, depending on the spatial resolution used. Although this technique is extensively used, accuracy verification of measurements is hard to obtain because the existing calibrated samples (phantoms) have large volumes and are assessed in medical CT scanners with millimeter spatial resolution. Accordingly, this study aims to determine the accuracy of an X-ray computed microtomography system using a Skyscan 1172 X-ray microtomograph. To accomplish this investigation, it was used a nylon thread set with known appropriate diameter inserted into a glass tube. The results for porosity size and phase distribution by X-ray microtomography were very close to the geometrically calculated values. The geometrically calculated porosity and the porosity determined by the methodology using the μ-CT was 33.4±3.4% and 31.0±0.3%, respectively. The outcome of this investigation was excellent. It was also observed a small variability in the results along all 401 sections of the analyzed image. Minimum and maximum porosity values between the cross sections were 30.9% and 31.1%, respectively. A 3-D image representing the actual structure of the sample was also rendered from the 2-D images. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Solid Lubrication Fundamentals and Applications. Chapter 2

    NASA Technical Reports Server (NTRS)

    Miyoshi, Kazuhisa

    1998-01-01

    This chapter describes powerful analytical techniques capable of sampling tribological surfaces and solid-film lubricants. Some of these techniques may also be used to determine the locus of failure in a bonded structure or coated substrate; such information is important when seeking improved adhesion between a solid-film lubricant and a substrate and when seeking improved performance and long life expectancy of solid lubricants. Many examples are given here and through-out the book on the nature and character of solid surfaces and their significance in lubrication, friction, and wear. The analytical techniques used include the late spectroscopic methods.

  13. Qualitative evaluation of maternal milk and commercial infant formulas via LIBS.

    PubMed

    Abdel-Salam, Z; Al Sharnoubi, J; Harith, M A

    2013-10-15

    This study focuses on the use of laser-induced breakdown spectroscopy (LIBS) for the evaluation of the nutrients in maternal milk and some commercially available infant formulas. The results of such evaluation are vital for adequate and healthy feeding for babies during lactation period. Laser-induced breakdown spectroscopy offers special advantages in comparison to the other conventional analytical techniques. Specifically, LIBS is a straightforward technique that can be used in situ to provide qualitative analytical information in few minutes for the samples under investigation without preparation processes. The samples studied in the current work were maternal milk samples collected during the first 3 months of lactation (not colostrum milk) and samples from six different types of commercially available infant formulas. The samples' elemental composition has been compared with respect to the relative abundance of the elements of nutrition importance, namely Mg, Ca, Na, and Fe using their spectral emission lines in the relevant LIBS spectra. In addition, CN and C2 molecular emission bands in the same spectra have been studied as indicators of proteins content in the samples. The obtained analytical results demonstrate the higher elemental contents of the maternal milk compared with the commercial formulas samples. Similar results have been obtained as for the proteins content. It has been also shown that calcium and proteins have similar relative concentration trends in the studied samples. This work demonstrates the feasibility of adopting LIBS as a fast, safe, less costly technique evaluating qualitatively the nutrients content of both maternal and commercial milk samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. [Recent Development of Atomic Spectrometry in China].

    PubMed

    Xiao, Yuan-fang; Wang, Xiao-hua; Hang, Wei

    2015-09-01

    As an important part of modern analytical techniques, atomic spectrometry occupies a decisive status in the whole analytical field. The development of atomic spectrometry also reflects the continuous reform and innovation of analytical techniques. In the past fifteen years, atomic spectrometry has experienced rapid development and been applied widely in many fields in China. This review has witnessed its development and remarkable achievements. It contains several directions of atomic spectrometry, including atomic emission spectrometry (AES), atomic absorption spectrometry (AAS), atomic fluorescence spectrometry (AFS), X-ray fluorescence spectrometry (XRF), and atomic mass spectrometry (AMS). Emphasis is put on the innovation of the detection methods and their applications in related fields, including environmental samples, biological samples, food and beverage, and geological materials, etc. There is also a brief introduction to the hyphenated techniques utilized in atomic spectrometry. Finally, the prospects of atomic spectrometry in China have been forecasted.

  15. Medicine, material science and security: the versatility of the coded-aperture approach.

    PubMed

    Munro, P R T; Endrizzi, M; Diemoz, P C; Hagen, C K; Szafraniec, M B; Millard, T P; Zapata, C E; Speller, R D; Olivo, A

    2014-03-06

    The principal limitation to the widespread deployment of X-ray phase imaging in a variety of applications is probably versatility. A versatile X-ray phase imaging system must be able to work with polychromatic and non-microfocus sources (for example, those currently used in medical and industrial applications), have physical dimensions sufficiently large to accommodate samples of interest, be insensitive to environmental disturbances (such as vibrations and temperature variations), require only simple system set-up and maintenance, and be able to perform quantitative imaging. The coded-aperture technique, based upon the edge illumination principle, satisfies each of these criteria. To date, we have applied the technique to mammography, materials science, small-animal imaging, non-destructive testing and security. In this paper, we outline the theory of coded-aperture phase imaging and show an example of how the technique may be applied to imaging samples with a practically important scale.

  16. Magneto-optical imaging technique for hostile environments: The ghost imaging approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meda, A.; Caprile, A.; Avella, A.

    2015-06-29

    In this paper, we develop an approach to magneto optical imaging (MOI), applying a ghost imaging (GI) protocol to perform Faraday microscopy. MOI is of the utmost importance for the investigation of magnetic properties of material samples, through Weiss domains shape, dimension and dynamics analysis. Nevertheless, in some extreme conditions such as cryogenic temperatures or high magnetic field applications, there exists a lack of domain images due to the difficulty in creating an efficient imaging system in such environments. Here, we present an innovative MOI technique that separates the imaging optical path from the one illuminating the object. The techniquemore » is based on thermal light GI and exploits correlations between light beams to retrieve the image of magnetic domains. As a proof of principle, the proposed technique is applied to the Faraday magneto-optical observation of the remanence domain structure of an yttrium iron garnet sample.« less

  17. Hyphenated analytical techniques for materials characterisation

    NASA Astrophysics Data System (ADS)

    Armstrong, Gordon; Kailas, Lekshmi

    2017-09-01

    This topical review will provide a survey of the current state of the art in ‘hyphenated’ techniques for characterisation of bulk materials, surface, and interfaces, whereby two or more analytical methods investigating different properties are applied simultaneously to the same sample to better characterise the sample than can be achieved by conducting separate analyses in series using different instruments. It is intended for final year undergraduates and recent graduates, who may have some background knowledge of standard analytical techniques, but are not familiar with ‘hyphenated’ techniques or hybrid instrumentation. The review will begin by defining ‘complementary’, ‘hybrid’ and ‘hyphenated’ techniques, as there is not a broad consensus among analytical scientists as to what each term means. The motivating factors driving increased development of hyphenated analytical methods will also be discussed. This introduction will conclude with a brief discussion of gas chromatography-mass spectroscopy and energy dispersive x-ray analysis in electron microscopy as two examples, in the context that combining complementary techniques for chemical analysis were among the earliest examples of hyphenated characterisation methods. The emphasis of the main review will be on techniques which are sufficiently well-established that the instrumentation is commercially available, to examine physical properties including physical, mechanical, electrical and thermal, in addition to variations in composition, rather than methods solely to identify and quantify chemical species. Therefore, the proposed topical review will address three broad categories of techniques that the reader may expect to encounter in a well-equipped materials characterisation laboratory: microscopy based techniques, scanning probe-based techniques, and thermal analysis based techniques. Examples drawn from recent literature, and a concluding case study, will be used to explain the practical issues that arise in combining different techniques. We will consider how the complementary and varied information obtained by combining these techniques may be interpreted together to better understand the sample in greater detail than that was possible before, and also how combining different techniques can simplify sample preparation and ensure reliable comparisons are made between multiple analyses on the same samples—a topic of particular importance as nanoscale technologies become more prevalent in applied and industrial research and development (R&D). The review will conclude with a brief outline of the emerging state of the art in the research laboratory, and a suggested approach to using hyphenated techniques, whether in the teaching, quality control or R&D laboratory.

  18. A NEW NON-AMBIGUOUS ANALYTICAL TECHNIQUE FOR THE IDENTIFICATION OF AEROSOL OXYGENATED COMPOUNDS

    EPA Science Inventory

    The most important organic products identified in the particle phase from field samples and from smog chamber experiments are polar oxygenated compounds containing one, two, three or more oxygenated functional groups (e.g. hydroxyl, carboxylic acid, ketone). Current procedures ...

  19. COMPARING PESTICIDE TRANSFERS FROM RESIDENTIAL SURFACE USING TRANSFERABLE RESIDUE SAMPLING TECHNIQUES AND VIDEO-FLUORESCENT IMAGING

    EPA Science Inventory

    The recent change from organophosphate (OP) to pyrethroid insecticides for indoor residential pest control may significantly affect the relative importance of different exposure routes because of differences in physical/chemical properties of these two classes of compounds. In...

  20. High-pressure sapphire cell for phase equilibria measurements of CO2/organic/water systems.

    PubMed

    Pollet, Pamela; Ethier, Amy L; Senter, James C; Eckert, Charles A; Liotta, Charles L

    2014-01-24

    The high pressure sapphire cell apparatus was constructed to visually determine the composition of multiphase systems without physical sampling. Specifically, the sapphire cell enables visual data collection from multiple loadings to solve a set of material balances to precisely determine phase composition. Ternary phase diagrams can then be established to determine the proportion of each component in each phase at a given condition. In principle, any ternary system can be studied although ternary systems (gas-liquid-liquid) are the specific examples discussed herein. For instance, the ternary THF-Water-CO2 system was studied at 25 and 40 °C and is described herein. Of key importance, this technique does not require sampling. Circumventing the possible disturbance of the system equilibrium upon sampling, inherent measurement errors, and technical difficulties of physically sampling under pressure is a significant benefit of this technique. Perhaps as important, the sapphire cell also enables the direct visual observation of the phase behavior. In fact, as the CO2 pressure is increased, the homogeneous THF-Water solution phase splits at about 2 MPa. With this technique, it was possible to easily and clearly observe the cloud point and determine the composition of the newly formed phases as a function of pressure. The data acquired with the sapphire cell technique can be used for many applications. In our case, we measured swelling and composition for tunable solvents, like gas-expanded liquids, gas-expanded ionic liquids and Organic Aqueous Tunable Systems (OATS)(1-4). For the latest system, OATS, the high-pressure sapphire cell enabled the study of (1) phase behavior as a function of pressure and temperature, (2) composition of each phase (gas-liquid-liquid) as a function of pressure and temperature and (3) catalyst partitioning in the two liquid phases as a function of pressure and composition. Finally, the sapphire cell is an especially effective tool to gather accurate and reproducible measurements in a timely fashion.

  1. The importance of anti corruption education teaching materials for the young generation

    NASA Astrophysics Data System (ADS)

    Sarmini; Made Swanda, I.; Nadiroh, Ulin

    2018-01-01

    Corruption is one of the most serious issues in many countries. The purpose of this paper is to identify the importance of anti-corruption education teaching materials for the younger generation. The research method used qualitative description with questionnaire as data collection tool. The sample in this research was 150 junior high school teachers in Surabaya. Data analysis technique used in this research was descriptive statistic with percentage technique. The result of this research was that Socisl Studies teachers in Surabaya realize that teaching materials on Anti-Corruption Education is very important in Social Studies learning activities. Recommendations for further research is to examine the antieducation teaching materials that contain the value of anti-corruption character. With anticorruption education is expected to give awareness and change to all the younger generation to understand and realize the importance of having the character of anti-corruption and can mengnglemlem in society.

  2. Wetlands Research Program. Evaluation of Methods for Sampling Vegetation and Delineating Wetlands Transition Zones in Southern Louisiana, January 1979-May 1981.

    DTIC Science & Technology

    1983-10-01

    sites should be collected and correlated to vegetational response through ordination or factor analysis techniques. 3. If site-specific methods are...specified number of samples is collected . If the 40 ."l ’ - - - .. -’-. - : -. .~ -, .4 .- . -.- , - ...... rb. . o* . -.% o - .- * .-.- v- . J...only, although the data collected were sufficient for determination of such parameters as density, cover, frequency, basal area, and importance value

  3. X-ray elemental mapping techniques for elucidating the ecophysiology of hyperaccumulator plants.

    PubMed

    van der Ent, Antony; Przybyłowicz, Wojciech J; de Jonge, Martin D; Harris, Hugh H; Ryan, Chris G; Tylko, Grzegorz; Paterson, David J; Barnabas, Alban D; Kopittke, Peter M; Mesjasz-Przybyłowicz, Jolanta

    2018-04-01

    Contents Summary 432 I. Introduction 433 II. Preparation of plant samples for X-ray micro-analysis 433 III. X-ray elemental mapping techniques 438 IV. X-ray data analysis 442 V. Case studies 443 VI. Conclusions 446 Acknowledgements 449 Author contributions 449 References 449 SUMMARY: Hyperaccumulators are attractive models for studying metal(loid) homeostasis, and probing the spatial distribution and coordination chemistry of metal(loid)s in their tissues is important for advancing our understanding of their ecophysiology. X-ray elemental mapping techniques are unique in providing in situ information, and with appropriate sample preparation offer results true to biological conditions of the living plant. The common platform of these techniques is a reliance on characteristic X-rays of elements present in a sample, excited either by electrons (scanning/transmission electron microscopy), protons (proton-induced X-ray emission) or X-rays (X-ray fluorescence microscopy). Elucidating the cellular and tissue-level distribution of metal(loid)s is inherently challenging and accurate X-ray analysis places strict demands on sample collection, preparation and analytical conditions, to avoid elemental redistribution, chemical modification or ultrastructural alterations. We compare the merits and limitations of the individual techniques, and focus on the optimal field of applications for inferring ecophysiological processes in hyperaccumulator plants. X-ray elemental mapping techniques can play a key role in answering questions at every level of metal(loid) homeostasis in plants, from the rhizosphere interface, to uptake pathways in the roots and shoots. Further improvements in technological capabilities offer exciting perspectives for the study of hyperaccumulator plants into the future. © 2017 University of Queensland. New Phytologist © 2017 New Phytologist Trust.

  4. Sensing Free Sulfur Dioxide in Wine

    PubMed Central

    Monro, Tanya M.; Moore, Rachel L.; Nguyen, Mai-Chi; Ebendorff-Heidepriem, Heike; Skouroumounis, George K.; Elsey, Gordon M.; Taylor, Dennis K.

    2012-01-01

    Sulfur dioxide (SO2) is important in the winemaking process as it aids in preventing microbial growth and the oxidation of wine. These processes and others consume the SO2 over time, resulting in wines with little SO2 protection. Furthermore, SO2 and sulfiting agents are known to be allergens to many individuals and for that reason their levels need to be monitored and regulated in final wine products. Many of the current techniques for monitoring SO2 in wine require the SO2 to be separated from the wine prior to analysis. This investigation demonstrates a technique capable of measuring free sulfite concentrations in low volume liquid samples in white wine. This approach adapts a known colorimetric reaction to a suspended core optical fiber sensing platform, and exploits the interaction between guided light located within the fiber voids and a mixture of the wine sample and a colorimetric analyte. We have shown that this technique enables measurements to be made without dilution of the wine samples, thus paving the way towards real time in situ wine monitoring. PMID:23112627

  5. Next generation techniques in the high resolution spectroscopy of biologically relevant molecules.

    PubMed

    Neill, Justin L; Douglass, Kevin O; Pate, Brooks H; Pratt, David W

    2011-04-28

    Recent advances in the technology of test and measurement equipment driven by the computer and telecommunications industries have made possible the development of a new broadband, Fourier-transform microwave spectrometer that operates on principles similar to FTNMR. This technique uses a high sample-rate arbitrary waveform generator to construct a phase-locked chirped microwave pulse that gives a linear frequency sweep over a wide frequency range in 1 μs. The chirped pulse efficiently polarizes the molecular sample at all frequencies lying within this band. The subsequent free induction decay of this polarization is measured with a high-speed digitizer and then fast Fourier-transformed to yield a broadband, frequency-resolved rotational spectrum, spanning up to 11.5 GHz and containing lines that are as narrow as 100 kHz. This new technique is called chirped-pulse Fourier transform microwave (CP-FTMW) spectroscopy. The technique offers the potential to determine the structural and dynamical properties of very large molecules solely from fully resolved pure rotational spectra. FTMW double resonance techniques employing a low-resolution UV laser facilitate an easy assignment of overlapping spectra produced by different conformers in the sample. Of particular interest are the energy landscapes of conformationally flexible molecules of biological importance, including studies of their interaction with solvent and/or other weakly bound molecules. An example is provided from the authors' work on p-methoxyphenethylamine, a neurotransmitter, and its complexes with water.

  6. Optimizing Tissue Sampling for the Diagnosis, Subtyping, and Molecular Analysis of Lung Cancer

    PubMed Central

    Ofiara, Linda Marie; Navasakulpong, Asma; Beaudoin, Stephane; Gonzalez, Anne Valerie

    2014-01-01

    Lung cancer has entered the era of personalized therapy with histologic subclassification and the presence of molecular biomarkers becoming increasingly important in therapeutic algorithms. At the same time, biopsy specimens are becoming increasingly smaller as diagnostic algorithms seek to establish diagnosis and stage with the least invasive techniques. Here, we review techniques used in the diagnosis of lung cancer including bronchoscopy, ultrasound-guided bronchoscopy, transthoracic needle biopsy, and thoracoscopy. In addition to discussing indications and complications, we focus our discussion on diagnostic yields and the feasibility of testing for molecular biomarkers such as epidermal growth factor receptor and anaplastic lymphoma kinase, emphasizing the importance of a sufficient tumor biopsy. PMID:25295226

  7. Optimising a modified free-space permittivity characterisation method for civil engineering applications

    NASA Astrophysics Data System (ADS)

    Muller, Wayne; Scheuermann, Alexander

    2016-04-01

    Measuring the electrical permittivity of civil engineering materials is important for a range of ground penetrating radar (GPR) and pavement moisture measurement applications. Compacted unbound granular (UBG) pavement materials present a number of preparation and measurement challenges using conventional characterisation techniques. As an alternative to these methods, a modified free-space (MFS) characterisation approach has previously been investigated. This paper describes recent work to optimise and validate the MFS technique. The research included finite difference time domain (FDTD) modelling to better understand the nature of wave propagation within material samples and the test apparatus. This research led to improvements in the test approach and optimisation of sample sizes. The influence of antenna spacing and sample thickness on the permittivity results was investigated by a series of experiments separating antennas and measuring samples of nylon and water. Permittivity measurements of samples of nylon and water approximately 100 mm and 170 mm thick were also compared, showing consistent results. These measurements also agreed well with surface probe measurements of the nylon sample and literature values for water. The results indicate permittivity estimates of acceptable accuracy can be obtained using the proposed approach, apparatus and sample sizes.

  8. Potential concerns with analytical Methods Used for the detection of Batrachochytrium salamandrivorans from archived DNA of amphibian swab samples, Oregon, USA

    USGS Publications Warehouse

    Iwanowicz, Deborah; Olson, Deanna H.; Adams, Michael J.; Adams, Cynthia; Anderson, Chauncey; Blaustein, Andrew R; Densmore, Christine L.; Figiel, Chester; Schill, William B.; Chestnut, Tara

    2017-01-01

    Taxonomic identification of pollen has historically been accomplished via light microscopy but requires specialized knowledge and reference collections, particularly when identification to lower taxonomic levels is necessary. Recently, next-generation sequencing technology has been used as a cost-effective alternative for identifying bee-collected pollen; however, this novel approach has not been tested on a spatially or temporally robust number of pollen samples. Here, we compare pollen identification results derived from light microscopy and DNA sequencing techniques with samples collected from honey bee colonies embedded within a gradient of intensive agricultural landscapes in the Northern Great Plains throughout the 2010–2011 growing seasons. We demonstrate that at all taxonomic levels, DNA sequencing was able to discern a greater number of taxa, and was particularly useful for the identification of infrequently detected species. Importantly, substantial phenological overlap did occur for commonly detected taxa using either technique, suggesting that DNA sequencing is an appropriate, and enhancing, substitutive technique for accurately capturing the breadth of bee-collected species of pollen present across agricultural landscapes. We also show that honey bees located in high and low intensity agricultural settings forage on dissimilar plants, though with overlap of the most abundantly collected pollen taxa. We highlight practical applications of utilizing sequencing technology, including addressing ecological issues surrounding land use, climate change, importance of taxa relative to abundance, and evaluating the impact of conservation program habitat enhancement efforts.

  9. A novel approach to the measurement of surfactant parameters in arthropod digestive juices.

    PubMed

    Romih, Tea; Kogej, Ksenija; Drobne, Damjana

    2016-05-01

    In arthropods, the determination of two important parameters of digestive juices, i.e. the total surfactant concentration and the critical micelle concentration (CMC), is challenging due to small sample volumes and low surfactant concentrations. In this work, we report a successful implementation of potentiometric titrations using the surfactant ion-selective electrode (SISE) and the pyrene fluorescence method (PFM) for the determination of the total surfactant concentration and CMC in the digestive juice of terrestrial isopod crustaceans Porcellio scaber. Pooled digestive juice extracts of four (SISE) or two (PFM) animals were used per measurement run. In both cases, digestive juice extracts in 100 μL of deionized water were sufficient for one measurement run. The total surfactant concentration of P. scaber digestive juice was determined to be 9.2 ± 3.5mM and the CMC was approximately 90 μM. Our work presents an important improvement towards easy CMC determination in small volume samples in comparison with the commonly used stalagmometric technique, where much larger sample volumes are usually needed. To date, the total surfactant concentration was not measured in the digestive juices of arthropods other than Homarus vulgaris, Astacus leptodactylus and Cancer pagurus, for which complex separation and analytical techniques were required. Our results obtained by SISE and PFM therefore present the first successful quantification of surfactants and their CMC in small volumes of arthropod digestive juice without prior separation or purification techniques. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Individual and organizational factors related to community clinicians’ use of therapy techniques in a large public mental health system

    PubMed Central

    Marcus, Steven; Aarons, Gregory A.; Hoagwood, Kimberly E.; Schoenwald, Sonja; Evans, Arthur C.; Hurford, Matthew O.; Hadley, Trevor; Barg, Frances K.; Walsh, Lucia M.; Adams, Danielle R.; Mandell, David S.

    2015-01-01

    Importance Few studies have examined the effects of both clinician and organizational characteristics on the use of evidence-based practices in mental healthcare. Improved understanding of these factors could guide future implementation efforts to ensure effective adoption, implementation, and sustainment of evidence-based practices. Objective To estimate the relative contribution of clinician and organizational factors on clinician self-reported use of cognitive-behavioral, family, and psychodynamic techniques within the context of a large-scale effort to increase use of evidence-based practices in an urban public mental health system serving youth and families. Design Observational and cross-sectional. Data collected in 2013. Setting Twenty-three organizations. Participants We used purposive sampling to recruit the 29 largest child-serving agencies, which together serve approximately 80% of youth receiving publically funded mental health care. The final sample included 19 agencies with 23 sites, 130 therapists, 36 supervisors, and 22 executive administrators. Main Outcome Measures Clinician self-reported use of cognitive-behavioral, family, and psychodynamic techniques, as measured by the Therapist Procedures Checklist – Family Revised. Results Linear mixed-effects regression models were used; models included random intercepts for organization to account for nesting of clinicians within organization. Clinician factors accounted for the following percentage of the overall variation: cognitive-behavioral (16%), family (7%), psychodynamic (20%). Organizational factors accounted for the following percentage of the overall variation: cognitive-behavioral (23%), family (19%), psychodynamic (7%). Older clinicians and clinicians with more open attitudes were more likely to endorse use of cognitive behavioral techniques, as were those in organizations that had spent fewer years participating in evidence-based practice initiatives, had more resistant cultures, and had more functional climates. Female clinicians were more likely to endorse use of family techniques, as were those in organizations employing more fee-for-service staff and with more stressful climates. Clinicians with more divergent attitudes and less knowledge about evidence-based practices were more likely to use psychodynamic techniques. Conclusions & Relevance This study suggests that both clinician and organizational factors are important in explaining clinician behavior and the use of evidence-based practices, but that their relative importance varies by therapeutic technique. PMID:25686473

  11. Imaging Extended Emission-Line Regions of Obscured AGN with the Subaru Hyper Suprime-Cam Survey

    NASA Astrophysics Data System (ADS)

    Sun, Ai-Lei; Greene, Jenny E.; Zakamska, Nadia L.; Goulding, Andy; Strauss, Michael A.; Huang, Song; Johnson, Sean; Kawaguchi, Toshihiro; Matsuoka, Yoshiki; Marsteller, Alisabeth A.; Nagao, Tohru; Toba, Yoshiki

    2018-05-01

    Narrow-line regions excited by active galactic nuclei (AGN) are important for studying AGN photoionization and feedback. Their strong [O III] lines can be detected with broadband images, allowing morphological studies of these systems with large-area imaging surveys. We develop a new broad-band imaging technique to reconstruct the images of the [O III] line using the Subaru Hyper Suprime-Cam (HSC) Survey aided with spectra from the Sloan Digital Sky Survey (SDSS). The technique involves a careful subtraction of the galactic continuum to isolate emission from the [O III]λ5007 and [O III]λ4959 lines. Compared to traditional targeted observations, this technique is more efficient at covering larger samples without dedicated observational resources. We apply this technique to an SDSS spectroscopically selected sample of 300 obscured AGN at redshifts 0.1 - 0.7, uncovering extended emission-line region candidates with sizes up to tens of kpc. With the largest sample of uniformly derived narrow-line region sizes, we revisit the narrow-line region size - luminosity relation. The area and radii of the [O III] emission-line regions are strongly correlated with the AGN luminosity inferred from the mid-infrared (15 μm rest-frame) with a power-law slope of 0.62^{+0.05}_{-0.06}± 0.10 (statistical and systematic errors), consistent with previous spectroscopic findings. We discuss the implications for the physics of AGN emission-line regions and future applications of this technique, which should be useful for current and next-generation imaging surveys to study AGN photoionization and feedback with large statistical samples.

  12. Raman spectroscopy-based detection of chemical contaminants in food powders

    USDA-ARS?s Scientific Manuscript database

    Raman spectroscopy technique has proven to be a reliable method for qualitative detection of chemical contaminants in food ingredients and products. For quantitative imaging-based detection, each contaminant particle in a food sample must be detected and it is important to determine the necessary sp...

  13. An efficient sampling technique for sums of bandpass functions

    NASA Technical Reports Server (NTRS)

    Lawton, W. M.

    1982-01-01

    A well known sampling theorem states that a bandlimited function can be completely determined by its values at a uniformly placed set of points whose density is at least twice the highest frequency component of the function (Nyquist rate). A less familiar but important sampling theorem states that a bandlimited narrowband function can be completely determined by its values at a properly chosen, nonuniformly placed set of points whose density is at least twice the passband width. This allows for efficient digital demodulation of narrowband signals, which are common in sonar, radar and radio interferometry, without the side effect of signal group delay from an analog demodulator. This theorem was extended by developing a technique which allows a finite sum of bandlimited narrowband functions to be determined by its values at a properly chosen, nonuniformly placed set of points whose density can be made arbitrarily close to the sum of the passband widths.

  14. Preparation of samples for leaf architecture studies, a method for mounting cleared leaves.

    PubMed

    Vasco, Alejandra; Thadeo, Marcela; Conover, Margaret; Daly, Douglas C

    2014-09-01

    Several recent waves of interest in leaf architecture have shown an expanding range of approaches and applications across a number of disciplines. Despite this increased interest, examination of existing archives of cleared and mounted leaves shows that current methods for mounting, in particular, yield unsatisfactory results and deterioration of samples over relatively short periods. Although techniques for clearing and staining leaves are numerous, published techniques for mounting leaves are scarce. • Here we present a complete protocol and recommendations for clearing, staining, and imaging leaves, and, most importantly, a method to permanently mount cleared leaves. • The mounting protocol is faster than other methods, inexpensive, and straightforward; moreover, it yields clear and permanent samples that can easily be imaged, scanned, and stored. Specimens mounted with this method preserve well, with leaves that were mounted more than 35 years ago showing no signs of bubbling or discoloration.

  15. Sparse Image Reconstruction on the Sphere: Analysis and Synthesis.

    PubMed

    Wallis, Christopher G R; Wiaux, Yves; McEwen, Jason D

    2017-11-01

    We develop techniques to solve ill-posed inverse problems on the sphere by sparse regularization, exploiting sparsity in both axisymmetric and directional scale-discretized wavelet space. Denoising, inpainting, and deconvolution problems and combinations thereof, are considered as examples. Inverse problems are solved in both the analysis and synthesis settings, with a number of different sampling schemes. The most effective approach is that with the most restricted solution-space, which depends on the interplay between the adopted sampling scheme, the selection of the analysis/synthesis problem, and any weighting of the l 1 norm appearing in the regularization problem. More efficient sampling schemes on the sphere improve reconstruction fidelity by restricting the solution-space and also by improving sparsity in wavelet space. We apply the technique to denoise Planck 353-GHz observations, improving the ability to extract the structure of Galactic dust emission, which is important for studying Galactic magnetism.

  16. High Accuracy Evaluation of the Finite Fourier Transform Using Sampled Data

    NASA Technical Reports Server (NTRS)

    Morelli, Eugene A.

    1997-01-01

    Many system identification and signal processing procedures can be done advantageously in the frequency domain. A required preliminary step for this approach is the transformation of sampled time domain data into the frequency domain. The analytical tool used for this transformation is the finite Fourier transform. Inaccuracy in the transformation can degrade system identification and signal processing results. This work presents a method for evaluating the finite Fourier transform using cubic interpolation of sampled time domain data for high accuracy, and the chirp Zeta-transform for arbitrary frequency resolution. The accuracy of the technique is demonstrated in example cases where the transformation can be evaluated analytically. Arbitrary frequency resolution is shown to be important for capturing details of the data in the frequency domain. The technique is demonstrated using flight test data from a longitudinal maneuver of the F-18 High Alpha Research Vehicle.

  17. Map showing geochemical data for panned stream sediments from the Bread Loaf Further Planning Area, Addison and Washington counties, Vermont

    USGS Publications Warehouse

    Grosz, A.E.; Schruben, P.G.; Atelsek, P.J.

    1987-01-01

    A geochemical survey of bedrock samples in the Bread Loaf Roadless Area (index map; fig. 1) was conducted by the U.S. Geological Survey (USGS) during October, 1981 in order to outline areas that may contain undiscovered mineral deposits. This report describes the results of a geochemical analysis of panned concentrates collected from stream sediments, and complements other geologic and geochemical investigations of the area (Slack and Bitar, 1983). The present study has offered us a chance to identify sampling media and a technique most appropriate for the enhancement of certain metallic elements in samples of panned concentrate. This study is important to the resource evaluation of the Bread Loaf Roadless Area because it reveals that geochemical anomalies produced by this technique are not evident in the standard magnetic and nonmagnetic fractions of panned concentrates.

  18. BATSE analysis techniques for probing the GRB spatial and luminosity distributions

    NASA Technical Reports Server (NTRS)

    Hakkila, Jon; Meegan, Charles A.

    1992-01-01

    The Burst And Transient Source Experiment (BATSE) has measured homogeneity and isotropy parameters from an increasingly large sample of observed gamma-ray bursts (GRBs), while also maintaining a summary of the way in which the sky has been sampled. Measurement of both of these are necessary for any study of the BATSE data statistically, as they take into account the most serious observational selection effects known in the study of GRBs: beam-smearing and inhomogeneous, anisotropic sky sampling. Knowledge of these effects is important to analysis of GRB angular and intensity distributions. In addition to determining that the bursts are local, it is hoped that analysis of such distributions will allow boundaries to be placed on the true GRB spatial distribution and luminosity function. The technique for studying GRB spatial and luminosity distributions is direct. Results of BATSE analyses are compared to Monte Carlo models parameterized by a variety of spatial and luminosity characteristics.

  19. Rope-based oral fluid sampling for early detection of classical swine fever in domestic pigs at group level.

    PubMed

    Dietze, Klaas; Tucakov, Anna; Engel, Tatjana; Wirtz, Sabine; Depner, Klaus; Globig, Anja; Kammerer, Robert; Mouchantat, Susan

    2017-01-05

    Non-invasive sampling techniques based on the analysis of oral fluid specimen have gained substantial importance in the field of swine herd management. Methodological advances have a focus on endemic viral diseases in commercial pig production. More recently, these approaches have been adapted to non-invasive sampling of wild boar for transboundary animal disease detection for which these effective population level sampling methods have not been available. In this study, a rope-in-a-bait based oral fluid sampling technique was tested to detect classical swine fever virus nucleic acid shedding from experimentally infected domestic pigs. Separated in two groups treated identically, the course of the infection was slightly differing in terms of onset of the clinical signs and levels of viral ribonucleic acid detection in the blood and oral fluid. The technique was capable of detecting classical swine fever virus nucleic acid as of day 7 post infection coinciding with the first detection in conventional oropharyngeal swab samples from some individual animals. Except for day 7 post infection in the "slower onset group", the chances of classical swine fever virus nucleic acid detection in ropes were identical or higher as compared to the individual sampling. With the provided evidence, non-invasive oral fluid sampling at group level can be considered as additional cost-effective detection tool in classical swine fever prevention and control strategies. The proposed methodology is of particular use in production systems with reduced access to veterinary services such as backyard or scavenging pig production where it can be integrated in feeding or baiting practices.

  20. A comparative analysis of conventional cytopreparatory and liquid based cytological techniques (Sure Path) in evaluation of serous effusion fluids.

    PubMed

    Dadhich, Hrishikesh; Toi, Pampa Ch; Siddaraju, Neelaiah; Sevvanthi, Kalidas

    2016-11-01

    Clinically, detection of malignant cells in serous body fluids is critical, as their presence implies the upstaging of the disease. Cytology of body cavity fluids serves as an important tool when other diagnostic tests cannot be performed. In most laboratories, currently, the effusion fluid samples are analysed chiefly by the conventional cytopreparatory (CCP) technique. Although, there are several studies comparing the liquid-based cytology (LBC), with CCP technique in the field of cervicovaginal cytology; the literature on such comparison with respect to serous body fluid examination is sparse. One hundred samples of serous body fluids were processed by both CCP and LBC techniques. Slides prepared by these techniques were studied using six parameters. A comparative analysis of the advantages and disadvantages of the techniques in detection of malignant cells was carried out with appropriate statistical tests. The samples comprised 52 pleural, 44 peritoneal and four pericardial fluids. No statistically significant difference was noted with respect to cellularity (P values = 0.22), cell distribution (P values = 0.39) and diagnosis of malignancy (P values = 0.20). As for the remaining parameters, LBC provided statistically significant clearer smear background (P values < 0.0001) and shorter screening time (P values < 0.0001), while CPP technique provided a significantly better staining quality (P values 0.01) and sharper cytomorphologic features (P values 0.05). Although, a reduced screening time and clearer smear background are the two major advantages of LBC; the CCP technique provides the better staining quality with sharper cytomorphologic features which is more critical from the cytologic interpretation point of view. Diagn. Cytopathol. 2016;44:874-879. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  1. Column-coupling strategies for multidimensional electrophoretic separation techniques.

    PubMed

    Kler, Pablo A; Sydes, Daniel; Huhn, Carolin

    2015-01-01

    Multidimensional electrophoretic separations represent one of the most common strategies for dealing with the analysis of complex samples. In recent years we have been witnessing the explosive growth of separation techniques for the analysis of complex samples in applications ranging from life sciences to industry. In this sense, electrophoretic separations offer several strategic advantages such as excellent separation efficiency, different methods with a broad range of separation mechanisms, and low liquid consumption generating less waste effluents and lower costs per analysis, among others. Despite their impressive separation efficiency, multidimensional electrophoretic separations present some drawbacks that have delayed their extensive use: the volumes of the columns, and consequently of the injected sample, are significantly smaller compared to other analytical techniques, thus the coupling interfaces between two separations components must be very efficient in terms of providing geometrical precision with low dead volume. Likewise, very sensitive detection systems are required. Additionally, in electrophoretic separation techniques, the surface properties of the columns play a fundamental role for electroosmosis as well as the unwanted adsorption of proteins or other complex biomolecules. In this sense the requirements for an efficient coupling for electrophoretic separation techniques involve several aspects related to microfluidics and physicochemical interactions of the electrolyte solutions and the solid capillary walls. It is interesting to see how these multidimensional electrophoretic separation techniques have been used jointly with different detection techniques, for intermediate detection as well as for final identification and quantification, particularly important in the case of mass spectrometry. In this work we present a critical review about the different strategies for coupling two or more electrophoretic separation techniques and the different intermediate and final detection methods implemented for such separations.

  2. Quadrupole magnetic field-flow fractionation: A novel technique for the characterization of magnetic particles

    NASA Astrophysics Data System (ADS)

    Carpino, Francesca

    In the last few decades, the development and use of nanotechnology has become of increasing importance. Magnetic nanoparticles, because of their unique properties, have been employed in many different areas of application. They are generally made of a core of magnetic material coated with some other material to stabilize them and to help disperse them in suspension. The unique feature of magnetic nanoparticles is their response to a magnetic field. They are generally superparamagnetic, in which case they become magnetized only in a magnetic field and lose their magnetization when the field is removed. It is this feature that makes them so useful for drug targeting, hyperthermia and bioseparation. For many of these applications, the synthesis of uniformly sized magnetic nanoparticles is of key importance because their magnetic properties depend strongly on their dimensions. Because of the difficulty of synthesizing monodisperse particulate materials, a technique capable of characterizing the magnetic properties of polydisperse samples is of great importance. Quadrupole magnetic field-flow fractionation (MgFFF) is a technique capable of fractionating magnetic particles based on their content of magnetite or other magnetic material. In MgFFF, the interplay of hydrodynamic and magnetic forces separates the particles as they are carried along a separation channel. Since the magnetic field and the gradient in magnetic field acting on the particles during their migration are known, it is possible to calculate the quantity of magnetic material in the particles according to their time of emergence at the channel outlet. Knowing the magnetic properties of the core material, MgFFF can be used to determine both the size distribution and the mean size of the magnetic cores of polydisperse samples. When magnetic material is distributed throughout the volume of the particles, the derived data corresponds to a distribution in equivalent spherical diameters of magnetic material in the particles. MgFFF is unique in its ability to characterize the distribution in magnetic properties of a particulate sample. This knowledge is not only of importance to the optimization and quality control of particle preparation. It is also of great importance in modeling magnetic cell separation, drug targeting, hyperthermia, and other areas of application.

  3. Green analytical chemistry--theory and practice.

    PubMed

    Tobiszewski, Marek; Mechlińska, Agata; Namieśnik, Jacek

    2010-08-01

    This tutorial review summarises the current state of green analytical chemistry with special emphasis on environmentally friendly sample preparation techniques. Green analytical chemistry is a part of the sustainable development concept; its history and origins are described. Miniaturisation of analytical devices and shortening the time elapsing between performing analysis and obtaining reliable analytical results are important aspects of green analytical chemistry. Solventless extraction techniques, the application of alternative solvents and assisted extractions are considered to be the main approaches complying with green analytical chemistry principles.

  4. Recent mass spectrometry-based techniques and considerations for disulfide bond characterization in proteins.

    PubMed

    Lakbub, Jude C; Shipman, Joshua T; Desaire, Heather

    2018-04-01

    Disulfide bonds are important structural moieties of proteins: they ensure proper folding, provide stability, and ensure proper function. With the increasing use of proteins for biotherapeutics, particularly monoclonal antibodies, which are highly disulfide bonded, it is now important to confirm the correct disulfide bond connectivity and to verify the presence, or absence, of disulfide bond variants in the protein therapeutics. These studies help to ensure safety and efficacy. Hence, disulfide bonds are among the critical quality attributes of proteins that have to be monitored closely during the development of biotherapeutics. However, disulfide bond analysis is challenging because of the complexity of the biomolecules. Mass spectrometry (MS) has been the go-to analytical tool for the characterization of such complex biomolecules, and several methods have been reported to meet the challenging task of mapping disulfide bonds in proteins. In this review, we describe the relevant, recent MS-based techniques and provide important considerations needed for efficient disulfide bond analysis in proteins. The review focuses on methods for proper sample preparation, fragmentation techniques for disulfide bond analysis, recent disulfide bond mapping methods based on the fragmentation techniques, and automated algorithms designed for rapid analysis of disulfide bonds from liquid chromatography-MS/MS data. Researchers involved in method development for protein characterization can use the information herein to facilitate development of new MS-based methods for protein disulfide bond analysis. In addition, individuals characterizing biotherapeutics, especially by disulfide bond mapping in antibodies, can use this review to choose the best strategies for disulfide bond assignment of their biologic products. Graphical Abstract This review, describing characterization methods for disulfide bonds in proteins, focuses on three critical components: sample preparation, mass spectrometry data, and software tools.

  5. Prevalence of canine heartworm (Dirofilaria immitis) disease in dogs of central Portugal.

    PubMed

    Vieira, Ana Luísa; Vieira, Maria João; Oliveira, João Manuel; Simões, Ana Rita; Diez-Baños, Pablo; Gestal, Juan

    2014-01-01

    The aim of the present study was to determine the prevalence and risk factors concerning Dirofilaria immitis infection in dogs from Figueira da Foz, located in the central region of Portugal. In the period between November 2009 and January 2011, 304 blood samples were obtained from dogs over 1 year of age, with no previous history of heartworm prevention or diagnosis. Every blood sample was analyzed using varied laboratory techniques (direct microscopic evaluation of a fresh blood sample, the modified Knott technique, and the ELISA antigen detection test - IDEXX Snapp®). In the samples in which microfilaremia was detected, a histochemical technique using acid phosphatase staining was applied to identify the species of microfilariae. A total prevalence of 27.3% (83 out of 304) was found. We also found that 73.5% of all positive cases (61 out of 83) were microfilaremic, and 26.5% were occult infections (22 out of 83). By means of a histochemical technique Dirofilaria immitis was identified in 96.7% of microfilaremic samples. A multivariate model allowed us to identify the following risk factors for the presence of heartworm disease: age between 4 and 9 years, dogs living in a rural environment, large breed dogs, and living outdoors. This study shows for the first time the high prevalence of heartworm disease in a central area of Portugal and emphasizes the importance of systematic screening for this disease, as well as the need to prevent it in dogs in this area. © A.L. Vieira et al., published by EDP Sciences, 2014.

  6. Attenuation of species abundance distributions by sampling

    PubMed Central

    Shimadzu, Hideyasu; Darnell, Ross

    2015-01-01

    Quantifying biodiversity aspects such as species presence/ absence, richness and abundance is an important challenge to answer scientific and resource management questions. In practice, biodiversity can only be assessed from biological material taken by surveys, a difficult task given limited time and resources. A type of random sampling, or often called sub-sampling, is a commonly used technique to reduce the amount of time and effort for investigating large quantities of biological samples. However, it is not immediately clear how (sub-)sampling affects the estimate of biodiversity aspects from a quantitative perspective. This paper specifies the effect of (sub-)sampling as attenuation of the species abundance distribution (SAD), and articulates how the sampling bias is induced to the SAD by random sampling. The framework presented also reveals some confusion in previous theoretical studies. PMID:26064626

  7. A comparison of mini-FLOTAC and FLOTAC with classic methods to diagnosing intestinal parasites of dogs from Brazil.

    PubMed

    Lima, Victor Fernando Santana; Cringoli, Giuseppe; Rinaldi, Laura; Monteiro, Maria Fernanda Melo; Calado, Andréa Maria Campos; Ramos, Rafael Antonio Nascimento; Meira-Santos, Patrícia Oliveira; Alves, Leucio Câmara

    2015-09-01

    Dogs may be affected by different species of gastrointestinal parasites which present great importance in veterinary medicine and public health. Several techniques to diagnosing these parasites have been proposed, but different performances achieved by each method make difficult the choice of the best technique to be used. In this study, the performance of two classic methods (i.e., Willis and Hoffman techniques) and two recent techniques (i.e., FLOTAC and Mini-FLOTAC) to diagnosing gastrointestinal parasites of dogs was evaluated. Fecal samples (n = 127) of dogs divided in pools (n = 30) were collected and analyzed using four different techniques (see above). Eggs and/or oocysts of gastrointestinal parasites were detected in 93.3 % (28/30) of the samples. In particular, 20 % (6/30) were detected through the method of Hoffman, 53.3 % (16/30) by the Willis technique, and 63.3 % (19/30) and 90 % (27/30) by Mini-FLOTAC and FLOTAC, respectively. Ancylostomatidae, Trichuris vulpis and Toxocara canis were the most frequent parasites herein detected. The FLOTAC and Mini-FLOTAC techniques were the most efficient tools to detect eggs and/or oocysts of gastrointestinal parasites of dogs, therefore their use is recommended in the laboratorial routine of veterinary medicine. This study is the first report of the use of both techniques (i.e., FLOTAC and Mini-FLOTAC) to diagnosing parasites of dogs in Brazil.

  8. Identification of Aroma Compounds of Lamiaceae Species in Turkey Using the Purge and Trap Technique

    PubMed Central

    Sonmezdag, Ahmet Salih; Kelebek, Hasim; Selli, Serkan

    2017-01-01

    The present research was planned to characterize the aroma composition of important members of the Lamiaceae family such as Salvia officinalis, Lavandula angustifolia and Mentha asiatica. Aroma components of the S. officinalis, L. angustifolia and M. asiatica were extracted with the purge and trap technique with dichloromethane and analyzed with the gas chromatography–mass spectrometry (GC–MS) technique. A total of 23, 33 and 33 aroma compounds were detected in Salvia officinalis, Lavandula angustifolia and Mentha asiatica, respectively including, acids, alcohols, aldehydes, esters, hydrocarbons and terpenes. Terpene compounds were both qualitatively and quantitatively the major chemical group among the identified aroma compounds, followed by esters. The main terpene compounds were 1,8-cineole, sabinene and linalool in Salvia officinalis, Lavandula angustifolia and Mentha asiatica, respectively. Among esters, linalyl acetate was the only and most important ester compound which was detected in all samples. PMID:28231089

  9. Identification of Aroma Compounds of Lamiaceae Species in Turkey Using the Purge and Trap Technique.

    PubMed

    Sonmezdag, Ahmet Salih; Kelebek, Hasim; Selli, Serkan

    2017-02-08

    The present research was planned to characterize the aroma composition of important members of the Lamiaceae family such as Salvia officinalis , Lavandula angustifolia and Mentha asiatica . Aroma components of the S. officinalis , L. angustifolia and M. asiatica were extracted with the purge and trap technique with dichloromethane and analyzed with the gas chromatography-mass spectrometry (GC-MS) technique. A total of 23, 33 and 33 aroma compounds were detected in Salvia officinalis , Lavandula angustifolia and Mentha asiatica , respectively including, acids, alcohols, aldehydes, esters, hydrocarbons and terpenes. Terpene compounds were both qualitatively and quantitatively the major chemical group among the identified aroma compounds, followed by esters. The main terpene compounds were 1,8-cineole, sabinene and linalool in Salvia officinalis , Lavandula angustifolia and Mentha asiatica , respectively. Among esters, linalyl acetate was the only and most important ester compound which was detected in all samples.

  10. A perception and manipulation system for collecting rock samples

    NASA Technical Reports Server (NTRS)

    Choi, T.; Delingette, H.; Deluise, M.; Hsin, Y.; Hebert, M.; Ikeuchi, Katsushi

    1991-01-01

    An important part of a planetary exploration mission is to collect and analyze surface samples. As part of the Carnegie Mellon University Ambler Project, researchers are investigating techniques for collecting samples using a robot arm and a range sensor. The aim of this work is to make the sample collection operation fully autonomous. Described here are the components of the experimental system, including a perception module that extracts objects of interest from range images and produces models of their shapes, and a manipulation module that enables the system to pick up the objects identified by the perception module. The system was tested on a small testbed using natural terrain.

  11. Improving the accuracy of effect-directed analysis: the role of bioavailability.

    PubMed

    You, Jing; Li, Huizhen

    2017-12-13

    Aquatic ecosystems have been suffering from contamination by multiple stressors. Traditional chemical-based risk assessment usually fails to explain the toxicity contributions from contaminants that are not regularly monitored or that have an unknown identity. Diagnosing the causes of noted adverse outcomes in the environment is of great importance in ecological risk assessment and in this regard effect-directed analysis (EDA) has been designed to fulfill this purpose. The EDA approach is now increasingly used in aquatic risk assessment owing to its specialty in achieving effect-directed nontarget analysis; however, a lack of environmental relevance makes conventional EDA less favorable. In particular, ignoring the bioavailability in EDA may cause a biased and even erroneous identification of causative toxicants in a mixture. Taking bioavailability into consideration is therefore of great importance to improve the accuracy of EDA diagnosis. The present article reviews the current status and applications of EDA practices that incorporate bioavailability. The use of biological samples is the most obvious way to include bioavailability into EDA applications, but its development is limited due to the small sample size and lack of evidence for metabolizable compounds. Bioavailability/bioaccessibility-based extraction (bioaccessibility-directed and partitioning-based extraction) and passive-dosing techniques are recommended to be used to integrate bioavailability into EDA diagnosis in abiotic samples. Lastly, the future perspectives of expanding and standardizing the use of biological samples and bioavailability-based techniques in EDA are discussed.

  12. Coalescent: an open-science framework for importance sampling in coalescent theory.

    PubMed

    Tewari, Susanta; Spouge, John L

    2015-01-01

    Background. In coalescent theory, computer programs often use importance sampling to calculate likelihoods and other statistical quantities. An importance sampling scheme can exploit human intuition to improve statistical efficiency of computations, but unfortunately, in the absence of general computer frameworks on importance sampling, researchers often struggle to translate new sampling schemes computationally or benchmark against different schemes, in a manner that is reliable and maintainable. Moreover, most studies use computer programs lacking a convenient user interface or the flexibility to meet the current demands of open science. In particular, current computer frameworks can only evaluate the efficiency of a single importance sampling scheme or compare the efficiencies of different schemes in an ad hoc manner. Results. We have designed a general framework (http://coalescent.sourceforge.net; language: Java; License: GPLv3) for importance sampling that computes likelihoods under the standard neutral coalescent model of a single, well-mixed population of constant size over time following infinite sites model of mutation. The framework models the necessary core concepts, comes integrated with several data sets of varying size, implements the standard competing proposals, and integrates tightly with our previous framework for calculating exact probabilities. For a given dataset, it computes the likelihood and provides the maximum likelihood estimate of the mutation parameter. Well-known benchmarks in the coalescent literature validate the accuracy of the framework. The framework provides an intuitive user interface with minimal clutter. For performance, the framework switches automatically to modern multicore hardware, if available. It runs on three major platforms (Windows, Mac and Linux). Extensive tests and coverage make the framework reliable and maintainable. Conclusions. In coalescent theory, many studies of computational efficiency consider only effective sample size. Here, we evaluate proposals in the coalescent literature, to discover that the order of efficiency among the three importance sampling schemes changes when one considers running time as well as effective sample size. We also describe a computational technique called "just-in-time delegation" available to improve the trade-off between running time and precision by constructing improved importance sampling schemes from existing ones. Thus, our systems approach is a potential solution to the "2(8) programs problem" highlighted by Felsenstein, because it provides the flexibility to include or exclude various features of similar coalescent models or importance sampling schemes.

  13. An Evaluation of Techniques for Ranking Academic Information Systems Journals

    DTIC Science & Technology

    1993-09-23

    business schools . The instructions were to rank the top ten journals in order of decreasing importance. An importance/prestige index was 4 created...in the samples taken by each study could account for the variation in ranking. Doke and Luke (1987) surveyed deans of business schools (with...is unknown. Doke and Luke (1987) sent 45 their surveys primarily to business schools , whereas the surveys in our study went directly to MIS faculty

  14. Using Ion Exchange Chromatography to Separate and Quantify Complex Ions

    ERIC Educational Resources Information Center

    Johnson, Brian J.

    2014-01-01

    Ion exchange chromatography is an important technique in the separation of charged species, particularly in biological, inorganic, and environmental samples. In this experiment, students are supplied with a mixture of two substitution-inert complex ions. They separate the complexes by ion exchange chromatography using a "flash"…

  15. Colorimetric Measurements of Amylase Activity: Improved Accuracy and Efficiency with a Smartphone

    ERIC Educational Resources Information Center

    Dangkulwanich, Manchuta; Kongnithigarn, Kaness; Aurnoppakhun, Nattapat

    2018-01-01

    Routinely used in quantitative determination of various analytes, UV-vis spectroscopy is commonly taught in undergraduate chemistry laboratory courses. Because the technique measures the absorbance of light through the samples, losses from reflection and scattering by large molecules interfere with the measurement. To emphasize the importance of…

  16. An Application of Trimethylsilyl Derivatives with Temperature Programmed Gas Chromatography to the Senior Analytical Laboratory.

    ERIC Educational Resources Information Center

    Kelter, Paul B.; Carr, James D.

    1983-01-01

    Describes an experiment designed to teach temperature programed gas chromatography (TPGC) techniques and importance of derivatizing many classes of substrated to be separated. Includes equipment needed, procedures for making trimethylsilyl derivatives, applications, sample calculations, and typical results. Procedure required one, three-hour…

  17. Predicting Successful Mathematics Remediation among Latina/o Students

    ERIC Educational Resources Information Center

    Crisp, Gloria; Reyes, Nicole Alia Salis; Doran, Erin

    2017-01-01

    This study examines Latina/o students' remedial math needs and outcomes. Data were drawn from a national sample of Latina/o students. Hierarchical generalized linear modeling techniques were used to predict three successful remediation outcomes. Results highlight the importance of providing financial aid and academic support to Latina/o students,…

  18. Human and methodological sources of variability in the measurement of urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine.

    PubMed

    Barregard, Lars; Møller, Peter; Henriksen, Trine; Mistry, Vilas; Koppen, Gudrun; Rossner, Pavel; Sram, Radim J; Weimann, Allan; Poulsen, Henrik E; Nataf, Robert; Andreoli, Roberta; Manini, Paola; Marczylo, Tim; Lam, Patricia; Evans, Mark D; Kasai, Hiroshi; Kawai, Kazuaki; Li, Yun-Shan; Sakai, Kazuo; Singh, Rajinder; Teichert, Friederike; Farmer, Peter B; Rozalski, Rafal; Gackowski, Daniel; Siomek, Agnieszka; Saez, Guillermo T; Cerda, Concha; Broberg, Karin; Lindh, Christian; Hossain, Mohammad Bakhtiar; Haghdoost, Siamak; Hu, Chiung-Wen; Chao, Mu-Rong; Wu, Kuen-Yuh; Orhan, Hilmi; Senduran, Nilufer; Smith, Raymond J; Santella, Regina M; Su, Yali; Cortez, Czarina; Yeh, Susan; Olinski, Ryszard; Loft, Steffen; Cooke, Marcus S

    2013-06-20

    Urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG) is a widely used biomarker of oxidative stress. However, variability between chromatographic and ELISA methods hampers interpretation of data, and this variability may increase should urine composition differ between individuals, leading to assay interference. Furthermore, optimal urine sampling conditions are not well defined. We performed inter-laboratory comparisons of 8-oxodG measurement between mass spectrometric-, electrochemical- and ELISA-based methods, using common within-technique calibrants to analyze 8-oxodG-spiked phosphate-buffered saline and urine samples. We also investigated human subject- and sample collection-related variables, as potential sources of variability. Chromatographic assays showed high agreement across urines from different subjects, whereas ELISAs showed far more inter-laboratory variation and generally overestimated levels, compared to the chromatographic assays. Excretion rates in timed 'spot' samples showed strong correlations with 24 h excretion (the 'gold' standard) of urinary 8-oxodG (rp 0.67-0.90), although the associations were weaker for 8-oxodG adjusted for creatinine or specific gravity (SG). The within-individual excretion of 8-oxodG varied only moderately between days (CV 17% for 24 h excretion and 20% for first void, creatinine-corrected samples). This is the first comprehensive study of both human and methodological factors influencing 8-oxodG measurement, providing key information for future studies with this important biomarker. ELISA variability is greater than chromatographic assay variability, and cannot determine absolute levels of 8-oxodG. Use of standardized calibrants greatly improves intra-technique agreement and, for the chromatographic assays, importantly allows integration of results for pooled analyses. If 24 h samples are not feasible, creatinine- or SG-adjusted first morning samples are recommended.

  19. Advances and unresolved challenges in the structural characterization of isomeric lipids.

    PubMed

    Hancock, Sarah E; Poad, Berwyck L J; Batarseh, Amani; Abbott, Sarah K; Mitchell, Todd W

    2017-05-01

    As the field of lipidomics grows and its application becomes wide and varied it is important that we don't forget its foundation, i.e. the identification and measurement of molecular lipids. Advances in liquid chromatography and the emergence of ion mobility as a useful tool in lipid analysis are allowing greater separation of lipid isomers than ever before. At the same time, novel ion activation techniques, such as ozone-induced dissociation, are pushing lipid structural characterization by mass spectrometry to new levels. Nevertheless, the quantitative capacity of these techniques is yet to be proven and further refinements are required to unravel the high level of lipid complexity found in biological samples. At present there is no one technique capable of providing full structural characterization of lipids from a biological sample. There are however, numerous techniques now available (as discussed in this review) that could be deployed in a targeted approach. Moving forward, the combination of advanced separation and ion activation techniques is likely to provide mass spectrometry-based lipidomics with its best opportunity to achieve complete molecular-level lipid characterization and measurement from complex mixtures. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  20. [Comparison of the determination of cyclosporin-A in blood samples collected on filter paper and by the ordinary technique].

    PubMed

    Azevedo, L S; Manrique, R; Sabbaga, E

    1995-01-01

    Monitoring cyclosporin-A (CsA) blood levels is of utmost importance for the rational use of this drug. Although many centers perform transplants, in Brazil there are few laboratories able to measure CsA blood levels. Therefore making blood samples reach the laboratory emerged as a problem. Collection of blood on filter paper has been a technique used for a long time in special cases. PURPOSE--To confirm the usefulness of measuring CsA blood levels in blood samples collected on filter paper and in the usual way. METHOD--We studied twenty renal cadaver kidney recipients who were receiving CsA, azathioprine and prednisone. Ninety five blood samples were collected and divided into two aliquots. One of them was sent routinely to one laboratory to perform whole blood CsA measurements. From the other aliquot, 20 microliters were pipetted on filter paper. When dried they were mailed to the other laboratory, where, after elution, CsA was measured. In both cases radioimmunoassay with polyclonal antibody was used. RESULTS--Linear correlation between both measurements revealed r = 0.81 with no statistical difference. CONCLUSION--The technique showed to be useful in clinical practice. In countries with continental size, as Brazil, it may be very helpful.

  1. [Potentials in the regionalization of health indicators using small-area estimation methods : Exemplary results based on the 2009, 2010 and 2012 GEDA studies].

    PubMed

    Kroll, Lars Eric; Schumann, Maria; Müters, Stephan; Lampert, Thomas

    2017-12-01

    Nationwide health surveys can be used to estimate regional differences in health. Using traditional estimation techniques, the spatial depth for these estimates is limited due to the constrained sample size. So far - without special refreshment samples - results have only been available for larger populated federal states of Germany. An alternative is regression-based small-area estimation techniques. These models can generate smaller-scale data, but are also subject to greater statistical uncertainties because of the model assumptions. In the present article, exemplary regionalized results based on the studies "Gesundheit in Deutschland aktuell" (GEDA studies) 2009, 2010 and 2012, are compared to the self-rated health status of the respondents. The aim of the article is to analyze the range of regional estimates in order to assess the usefulness of the techniques for health reporting more adequately. The results show that the estimated prevalence is relatively stable when using different samples. Important determinants of the variation of the estimates are the achieved sample size on the district level and the type of the district (cities vs. rural regions). Overall, the present study shows that small-area modeling of prevalence is associated with additional uncertainties compared to conventional estimates, which should be taken into account when interpreting the corresponding findings.

  2. Methods for spectral image analysis by exploiting spatial simplicity

    DOEpatents

    Keenan, Michael R.

    2010-05-25

    Several full-spectrum imaging techniques have been introduced in recent years that promise to provide rapid and comprehensive chemical characterization of complex samples. One of the remaining obstacles to adopting these techniques for routine use is the difficulty of reducing the vast quantities of raw spectral data to meaningful chemical information. Multivariate factor analysis techniques, such as Principal Component Analysis and Alternating Least Squares-based Multivariate Curve Resolution, have proven effective for extracting the essential chemical information from high dimensional spectral image data sets into a limited number of components that describe the spectral characteristics and spatial distributions of the chemical species comprising the sample. There are many cases, however, in which those constraints are not effective and where alternative approaches may provide new analytical insights. For many cases of practical importance, imaged samples are "simple" in the sense that they consist of relatively discrete chemical phases. That is, at any given location, only one or a few of the chemical species comprising the entire sample have non-zero concentrations. The methods of spectral image analysis of the present invention exploit this simplicity in the spatial domain to make the resulting factor models more realistic. Therefore, more physically accurate and interpretable spectral and abundance components can be extracted from spectral images that have spatially simple structure.

  3. Methods for spectral image analysis by exploiting spatial simplicity

    DOEpatents

    Keenan, Michael R.

    2010-11-23

    Several full-spectrum imaging techniques have been introduced in recent years that promise to provide rapid and comprehensive chemical characterization of complex samples. One of the remaining obstacles to adopting these techniques for routine use is the difficulty of reducing the vast quantities of raw spectral data to meaningful chemical information. Multivariate factor analysis techniques, such as Principal Component Analysis and Alternating Least Squares-based Multivariate Curve Resolution, have proven effective for extracting the essential chemical information from high dimensional spectral image data sets into a limited number of components that describe the spectral characteristics and spatial distributions of the chemical species comprising the sample. There are many cases, however, in which those constraints are not effective and where alternative approaches may provide new analytical insights. For many cases of practical importance, imaged samples are "simple" in the sense that they consist of relatively discrete chemical phases. That is, at any given location, only one or a few of the chemical species comprising the entire sample have non-zero concentrations. The methods of spectral image analysis of the present invention exploit this simplicity in the spatial domain to make the resulting factor models more realistic. Therefore, more physically accurate and interpretable spectral and abundance components can be extracted from spectral images that have spatially simple structure.

  4. Detection of Wuchereria bancrofti DNA in paired serum and urine samples using polymerase chain reaction-based systems.

    PubMed

    Ximenes, Camila; Brandão, Eduardo; Oliveira, Paula; Rocha, Abraham; Rego, Tamisa; Medeiros, Rafael; Aguiar-Santos, Ana; Ferraz, João; Reis, Christian; Araujo, Paulo; Carvalho, Luiz; Melo, Fabio L

    2014-12-01

    The Global Program for the Elimination of Lymphatic Filariasis (GPELF) aims to eliminate this disease by the year 2020. However, the development of more specific and sensitive tests is important for the success of the GPELF. The present study aimed to standardise polymerase chain reaction (PCR)-based systems for the diagnosis of filariasis in serum and urine. Twenty paired biological urine and serum samples from individuals already known to be positive for Wuchereria bancrofti were collected during the day. Conventional PCR and semi-nested PCR assays were optimised. The detection limit of the technique for purified W. bancrofti DNA extracted from adult worms was 10 fg for the internal systems (WbF/Wb2) and 0.1 fg by using semi-nested PCR. The specificity of the primers was confirmed experimentally by amplification of 1 ng of purified genomic DNA from other species of parasites. Evaluation of the paired urine and serum samples by the semi-nested PCR technique indicated only two of the 20 tested individuals were positive, whereas the simple internal PCR system (WbF/Wb2), which has highly promising performance, revealed that all the patients were positive using both samples. This study successfully demonstrated the possibility of using the PCR technique on urine for the diagnosis of W. bancrofti infection.

  5. Non-contact Creep Resistance Measurement for Ultra-high temperature Materials

    NASA Technical Reports Server (NTRS)

    Hyers, Robert W.; Lee, Jonghuyn; Bradshaw, Richard C.; Rogers, Jan; Rathz, Thomas J.; Wall, James J.; Choo, Hahn; Liaw, Peter K.

    2005-01-01

    Continuing pressures for higher performance and efficiency in propulsion are driving ever more demanding needs for high-temperature materials. Some immediate applications in spaceflight include combustion chambers for advanced chemical rockets and turbomachinery for jet engines and power conversion in nuclear-electric propulsion. In the case of rockets, the combination of high stresses and high temperatures make the characterization of creep properties very important. Creep is even more important in the turbomachinery, where a long service life is an additional constraint. Some very high-temperature materials are being developed, including platinum group metals, carbides, borides, and silicides. But the measurement of creep properties at very high temperatures is itself problematic, because the testing instrument must operate at such high temperatures. Conventional techniques are limited to about 1700 C. A new, containerless technique for measuring creep deformation has been developed. This technique is based on electrostatic levitation (ESL) of a spherical sample, which is heated to the measurement temperature and rotated at a rate such that the centrifugal acceleration causes creep deformation. Creep of samples has been demonstrated at up to 2300 C in the ESL facility at NASA MSFC, while ESL itself has been applied at over 3000 C, and has no theoretical maximum temperature. The preliminary results and future directions of this NASA-funded research collaboration will be presented.

  6. Mars chronology: Assessing techniques for quantifying surficial processes

    USGS Publications Warehouse

    Doran, P.T.; Clifford, S.M.; Forman, S.L.; Nyquist, Larry; Papanastassiou, D.A.; Stewart, B.W.; Sturchio, N.C.; Swindle, T.D.; Cerling, T.; Kargel, J.; McDonald, G.; Nishiizumi, K.; Poreda, R.; Rice, J.W.; Tanaka, K.

    2004-01-01

    Currently, the absolute chronology of Martian rocks, deposits and events is based mainly on crater counting and remains highly imprecise with epoch boundary uncertainties in excess of 2 billion years. Answers to key questions concerning the comparative origin and evolution of Mars and Earth will not be forthcoming without a rigid Martian chronology, enabling the construction of a time scale comparable to Earth's. Priorities for exploration include calibration of the cratering rate, dating major volcanic and fluvial events and establishing chronology of the polar layered deposits. If extinct and/or extant life is discovered, the chronology of the biosphere will be of paramount importance. Many radiometric and cosmogenic techniques applicable on Earth and the Moon will apply to Mars after certain baselines (e.g. composition of the atmosphere, trace species, chemical and physical characteristics of Martian dust) are established. The high radiation regime may pose a problem for dosimetry-based techniques (e.g. luminescence). The unique isotopic composition of nitrogen in the Martian atmosphere may permit a Mars-specific chronometer for tracing the time-evolution of the atmosphere and of lithic phases with trapped atmospheric gases. Other Mars-specific chronometers include measurement of gas fluxes and accumulation of platinum group elements (PGE) in the regolith. Putting collected samples into geologic context is deemed essential, as is using multiple techniques on multiple samples. If in situ measurements are restricted to a single technique it must be shown to give consistent results on multiple samples, but in all cases, using two or more techniques (e.g. on the same lander) will reduce error. While there is no question that returned samples will yield the best ages, in situ techniques have the potential to be flown on multiple missions providing a larger data set and broader context in which to place the more accurate dates. ?? 2004 Elsevier B.V. All rights reserved.

  7. Principles, Techniques, and Applications of Tissue Microfluidics

    NASA Technical Reports Server (NTRS)

    Wade, Lawrence A.; Kartalov, Emil P.; Shibata, Darryl; Taylor, Clive

    2011-01-01

    The principle of tissue microfluidics and its resultant techniques has been applied to cell analysis. Building microfluidics to suit a particular tissue sample would allow the rapid, reliable, inexpensive, highly parallelized, selective extraction of chosen regions of tissue for purposes of further biochemical analysis. Furthermore, the applicability of the techniques ranges beyond the described pathology application. For example, they would also allow the posing and successful answering of new sets of questions in many areas of fundamental research. The proposed integration of microfluidic techniques and tissue slice samples is called tissue microfluidics because it molds the microfluidic architectures in accordance with each particular structure of each specific tissue sample. Thus, microfluidics can be built around the tissues, following the tissue structure, or alternatively, the microfluidics can be adapted to the specific geometry of particular tissues. By contrast, the traditional approach is that microfluidic devices are structured in accordance with engineering considerations, while the biological components in applied devices are forced to comply with these engineering presets. The proposed principles represent a paradigm shift in microfluidic technology in three important ways: Microfluidic devices are to be directly integrated with, onto, or around tissue samples, in contrast to the conventional method of off-chip sample extraction followed by sample insertion in microfluidic devices. Architectural and operational principles of microfluidic devices are to be subordinated to suit specific tissue structure and needs, in contrast to the conventional method of building devices according to fluidic function alone and without regard to tissue structure. Sample acquisition from tissue is to be performed on-chip and is to be integrated with the diagnostic measurement within the same device, in contrast to the conventional method of off-chip sample prep and subsequent insertion into a diagnostic device. A more advanced form of tissue integration with microfluidics is tissue encapsulation, wherein the sample is completely encapsulated within a microfluidic device, to allow for full surface access. The immediate applications of these approaches lie with diagnostics of tissue slices and biopsy samples e.g. for cancer but the approaches would also be very useful in comparative genomics and other areas of fundamental research involving heterogeneous tissue samples.

  8. An Intrinsic Algorithm for Parallel Poisson Disk Sampling on Arbitrary Surfaces.

    PubMed

    Ying, Xiang; Xin, Shi-Qing; Sun, Qian; He, Ying

    2013-03-08

    Poisson disk sampling plays an important role in a variety of visual computing, due to its useful statistical property in distribution and the absence of aliasing artifacts. While many effective techniques have been proposed to generate Poisson disk distribution in Euclidean space, relatively few work has been reported to the surface counterpart. This paper presents an intrinsic algorithm for parallel Poisson disk sampling on arbitrary surfaces. We propose a new technique for parallelizing the dart throwing. Rather than the conventional approaches that explicitly partition the spatial domain to generate the samples in parallel, our approach assigns each sample candidate a random and unique priority that is unbiased with regard to the distribution. Hence, multiple threads can process the candidates simultaneously and resolve conflicts by checking the given priority values. It is worth noting that our algorithm is accurate as the generated Poisson disks are uniformly and randomly distributed without bias. Our method is intrinsic in that all the computations are based on the intrinsic metric and are independent of the embedding space. This intrinsic feature allows us to generate Poisson disk distributions on arbitrary surfaces. Furthermore, by manipulating the spatially varying density function, we can obtain adaptive sampling easily.

  9. The absence of lithium isotope fractionation during basalt differentiation: New measurements by multicollector sector ICP-MS

    USGS Publications Warehouse

    Tomascak, P.B.; Tera, F.; Helz, R.T.; Walker, R.J.

    1999-01-01

    We report measurements of the isotopic composition of lithium in basalts using a multicollector magnetic sector plasma-source mass spectrometer (MC-ICP-MS). This is the first application of this analytical technique to Li isotope determination. External precision of multiple replicate and duplicate measurements for a variety of sample types averages ??1.1??? (2?? population). The method allows for the rapid (???8 min/sample) analysis of small samples (???40 ng Li) relative to commonly used thermal ionization methods. The technique has been applied to a suite of samples from Kilauea Iki lava lake, Hawaii. The samples range from olivine-rich cumulitic lava to SiO2 - and K2O-enriched differentiated liquids, and have ??7Li (per mil deviation of sample 7Li/6Li relative to the L-SVEC standard) of +3.0 to +4.8. The data indicate a lack of per mil-level Li isotope fractionation as a result of crystal-liquid fractionation at temperatures greater than 1050??C. This conclusion has been tacitly assumed but never demonstrated, and is important to the interpretation of Li isotope results from such geochemically complex environments as island arcs. Copyright ?? 1999 Elsevier Science Ltd.

  10. Space Weather Activities of IONOLAB Group: TEC Mapping

    NASA Astrophysics Data System (ADS)

    Arikan, F.; Yilmaz, A.; Arikan, O.; Sayin, I.; Gurun, M.; Akdogan, K. E.; Yildirim, S. A.

    2009-04-01

    Being a key player in Space Weather, ionospheric variability affects the performance of both communication and navigation systems. To improve the performance of these systems, ionosphere has to be monitored. Total Electron Content (TEC), line integral of the electron density along a ray path, is an important parameter to investigate the ionospheric variability. A cost-effective way of obtaining TEC is by using dual-frequency GPS receivers. Since these measurements are sparse in space, accurate and robust interpolation techniques are needed to interpolate (or map) the TEC distribution for a given region in space. However, the TEC data derived from GPS measurements contain measurement noise, model and computational errors. Thus, it is necessary to analyze the interpolation performance of the techniques on synthetic data sets that can represent various ionospheric states. By this way, interpolation performance of the techniques can be compared over many parameters that can be controlled to represent the desired ionospheric states. In this study, Multiquadrics, Inverse Distance Weighting (IDW), Cubic Splines, Ordinary and Universal Kriging, Random Field Priors (RFP), Multi-Layer Perceptron Neural Network (MLP-NN), and Radial Basis Function Neural Network (RBF-NN) are employed as the spatial interpolation algorithms. These mapping techniques are initially tried on synthetic TEC surfaces for parameter and coefficient optimization and determination of error bounds. Interpolation performance of these methods are compared on synthetic TEC surfaces over the parameters of sampling pattern, number of samples, the variability of the surface and the trend type in the TEC surfaces. By examining the performance of the interpolation methods, it is observed that both Kriging, RFP and NN have important advantages and possible disadvantages depending on the given constraints. It is also observed that the determining parameter in the error performance is the trend in the Ionosphere. Optimization of the algorithms in terms of their performance parameters (like the choice of the semivariogram function for Kriging algorithms and the hidden layer and neuron numbers for MLP-NN) mostly depend on the behavior of the ionosphere at that given time instant for the desired region. The sampling pattern and number of samples are the other important parameters that may contribute to the higher errors in reconstruction. For example, for all of the above listed algorithms, hexagonal regular sampling of the ionosphere provides the lowest reconstruction error and the performance significantly degrades as the samples in the region become sparse and clustered. The optimized models and coefficients are applied to regional GPS-TEC mapping using the IONOLAB-TEC data (www.ionolab.org). Both Kriging combined with Kalman Filter and dynamic modeling of NN are also implemented as first trials of TEC and space weather predictions.

  11. Stochastic subset selection for learning with kernel machines.

    PubMed

    Rhinelander, Jason; Liu, Xiaoping P

    2012-06-01

    Kernel machines have gained much popularity in applications of machine learning. Support vector machines (SVMs) are a subset of kernel machines and generalize well for classification, regression, and anomaly detection tasks. The training procedure for traditional SVMs involves solving a quadratic programming (QP) problem. The QP problem scales super linearly in computational effort with the number of training samples and is often used for the offline batch processing of data. Kernel machines operate by retaining a subset of observed data during training. The data vectors contained within this subset are referred to as support vectors (SVs). The work presented in this paper introduces a subset selection method for the use of kernel machines in online, changing environments. Our algorithm works by using a stochastic indexing technique when selecting a subset of SVs when computing the kernel expansion. The work described here is novel because it separates the selection of kernel basis functions from the training algorithm used. The subset selection algorithm presented here can be used in conjunction with any online training technique. It is important for online kernel machines to be computationally efficient due to the real-time requirements of online environments. Our algorithm is an important contribution because it scales linearly with the number of training samples and is compatible with current training techniques. Our algorithm outperforms standard techniques in terms of computational efficiency and provides increased recognition accuracy in our experiments. We provide results from experiments using both simulated and real-world data sets to verify our algorithm.

  12. Performance of optimized McRAPD in identification of 9 yeast species frequently isolated from patient samples: potential for automation.

    PubMed

    Trtkova, Jitka; Pavlicek, Petr; Ruskova, Lenka; Hamal, Petr; Koukalova, Dagmar; Raclavsky, Vladislav

    2009-11-10

    Rapid, easy, economical and accurate species identification of yeasts isolated from clinical samples remains an important challenge for routine microbiological laboratories, because susceptibility to antifungal agents, probability to develop resistance and ability to cause disease vary in different species. To overcome the drawbacks of the currently available techniques we have recently proposed an innovative approach to yeast species identification based on RAPD genotyping and termed McRAPD (Melting curve of RAPD). Here we have evaluated its performance on a broader spectrum of clinically relevant yeast species and also examined the potential of automated and semi-automated interpretation of McRAPD data for yeast species identification. A simple fully automated algorithm based on normalized melting data identified 80% of the isolates correctly. When this algorithm was supplemented by semi-automated matching of decisive peaks in first derivative plots, 87% of the isolates were identified correctly. However, a computer-aided visual matching of derivative plots showed the best performance with average 98.3% of the accurately identified isolates, almost matching the 99.4% performance of traditional RAPD fingerprinting. Since McRAPD technique omits gel electrophoresis and can be performed in a rapid, economical and convenient way, we believe that it can find its place in routine identification of medically important yeasts in advanced diagnostic laboratories that are able to adopt this technique. It can also serve as a broad-range high-throughput technique for epidemiological surveillance.

  13. STRATEGIES FOR QUANTIFYING PET IMAGING DATA FROM TRACER STUDIES OF BRAIN RECEPTORS AND ENZYMES.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Logan, J.

    2001-04-02

    A description of some of the methods used in neuroreceptor imaging to distinguish changes in receptor availability has been presented in this chapter. It is necessary to look beyond regional uptake of the tracer since uptake generally is affected by factors other than the number of receptors for which the tracer has affinity. An exception is the infusion method producing an equilibrium state. The techniques vary in complexity some requiring arterial blood measurements of unmetabolized tracer and multiple time uptake data. Others require only a few plasma and uptake measurements and those based on a reference region require no plasmamore » measurements. We have outlined some of the limitations of the different methods. Laruelle (1999) has pointed out that test/retest studies to which various methods can be applied are crucial in determining the optimal method for a particular study. The choice of method will also depend upon the application. In a clinical setting, methods not involving arterial blood sampling are generally preferred. In the future techniques for externally measuring arterial plasma radioactivity with only a few blood samples for metabolite correction will extend the modeling options of clinical PET. Also since parametric images can provide information beyond that of ROI analysis, improved techniques for generating such images will be important, particularly for ligands requiring more than a one-compartment model. Techniques such as the wavelet transform proposed by Turkheimer et al. (2000) may prove to be important in reducing noise and improving quantitation.« less

  14. Monte Carlo sampling in diffusive dynamical systems

    NASA Astrophysics Data System (ADS)

    Tapias, Diego; Sanders, David P.; Altmann, Eduardo G.

    2018-05-01

    We introduce a Monte Carlo algorithm to efficiently compute transport properties of chaotic dynamical systems. Our method exploits the importance sampling technique that favors trajectories in the tail of the distribution of displacements, where deviations from a diffusive process are most prominent. We search for initial conditions using a proposal that correlates states in the Markov chain constructed via a Metropolis-Hastings algorithm. We show that our method outperforms the direct sampling method and also Metropolis-Hastings methods with alternative proposals. We test our general method through numerical simulations in 1D (box-map) and 2D (Lorentz gas) systems.

  15. [Parasites of zoonotic importance in dog feces collected in parks and public squares of the city of Los Angeles, Bío-Bío, Chile].

    PubMed

    Luzio, Álvaro; Belmar, Pablo; Troncoso, Ignacio; Luzio, Patricia; Jara, Alexis; Fernández, Ítalo

    2015-08-01

    The contamination of public squares and parks with dog feces poses a risk to the population, since it may contain parasitic elements of zoonotic importance. To identify human pathogenic parasites in samples of dog feces collected from parks and public squares. 452 fecal dog samples collected from 65 squares and public parks were analyzed using the technique of Burrows. 60% (39/65) of the samples contained some parasitic forms with a zoonotic potential. Parasitic taxa with zoonotic risk were Toxocara sp., Ancylostoma sp., Dipylidium caninum, Giardia sp., Taenia sp., Toxascaris sp., Strongyloides sp., and Uncinaria sp. The detected parasites present a risk to human health, so it seems necessary to implement health education activities in the community, develop deworming plans, and control the canine overpopulation.

  16. Identification of Particles in Parenteral Drug Raw Materials.

    PubMed

    Lee, Kathryn; Lankers, Markus; Valet, Oliver

    2018-04-18

    Particles in drug products are not good and are therefore regulated. These particles can come from the very beginning of the manufacturing process, from the raw materials. To prevent particles, it is important to understand what they are and where they come from so the raw material quality, processing, and shipping can be improved. Thus, it is important to correctly identify particles seen in raw materials. Raw materials need to be of a certain quality with respect to physical and chemical composition, and need to have no contaminants in the form of particles which could contaminate the product or indicate the raw materials are not pure enough to make a good quality product. Particles are often seen when handling raw materials due to color, size, or shape characteristics different from those in the raw materials. Particles may appear to the eye to be very different things than they actually are, so microscope, chemical, and elemental analyses are required for accuracy in proper identification. This paper shows how using three different spectroscopy tools correctly and together can be used to identify particles from extrinsic, intrinsic, and inherent particles. Sources of materials can be humans and the environment (extrinsic), from within the process (intrinsic), and part of the formulation (inherent). Microscope versions of Raman spectroscopy, laser-induced breakdown spectroscopy (LIBS), and IR spectroscopy are excellent tools for identifying particles because they are fast and accurate techniques needing minimal sample preparation that can provide chemical composition as well as images that can be used for identification. The micro analysis capabilities allow for easy analysis of different portions of samples so multiple components can be identified and sample preparation can be reduced. Using just one of these techniques may not be sufficient to give adequate identification results so that the source of contamination can be adequately identified. The complementarity of the techniques provides the advantage of identifying various chemical and molecular components, as well as elemental and image analyses. Correct interpretation of the results from these techniques is also very important. Copyright © 2018, Parenteral Drug Association.

  17. Behavioural cues of reproductive status in seahorses Hippocampus abdominalis.

    PubMed

    Whittington, C M; Musolf, K; Sommer, S; Wilson, A B

    2013-07-01

    A method is described to assess the reproductive status of male Hippocampus abdominalis on the basis of behavioural traits. The non-invasive nature of this technique minimizes handling stress and reduces sampling requirements for experimental work. It represents a useful tool to assist researchers in sample collection for studies of reproduction and development in viviparous syngnathids, which are emerging as important model species. © 2013 The Authors. Journal of Fish Biology © 2013 The Fisheries Society of the British Isles.

  18. Fitting distributions to microbial contamination data collected with an unequal probability sampling design.

    PubMed

    Williams, M S; Ebel, E D; Cao, Y

    2013-01-01

    The fitting of statistical distributions to microbial sampling data is a common application in quantitative microbiology and risk assessment applications. An underlying assumption of most fitting techniques is that data are collected with simple random sampling, which is often times not the case. This study develops a weighted maximum likelihood estimation framework that is appropriate for microbiological samples that are collected with unequal probabilities of selection. A weighted maximum likelihood estimation framework is proposed for microbiological samples that are collected with unequal probabilities of selection. Two examples, based on the collection of food samples during processing, are provided to demonstrate the method and highlight the magnitude of biases in the maximum likelihood estimator when data are inappropriately treated as a simple random sample. Failure to properly weight samples to account for how data are collected can introduce substantial biases into inferences drawn from the data. The proposed methodology will reduce or eliminate an important source of bias in inferences drawn from the analysis of microbial data. This will also make comparisons between studies and the combination of results from different studies more reliable, which is important for risk assessment applications. © 2012 No claim to US Government works.

  19. Honest Importance Sampling with Multiple Markov Chains

    PubMed Central

    Tan, Aixin; Doss, Hani; Hobert, James P.

    2017-01-01

    Importance sampling is a classical Monte Carlo technique in which a random sample from one probability density, π1, is used to estimate an expectation with respect to another, π. The importance sampling estimator is strongly consistent and, as long as two simple moment conditions are satisfied, it obeys a central limit theorem (CLT). Moreover, there is a simple consistent estimator for the asymptotic variance in the CLT, which makes for routine computation of standard errors. Importance sampling can also be used in the Markov chain Monte Carlo (MCMC) context. Indeed, if the random sample from π1 is replaced by a Harris ergodic Markov chain with invariant density π1, then the resulting estimator remains strongly consistent. There is a price to be paid however, as the computation of standard errors becomes more complicated. First, the two simple moment conditions that guarantee a CLT in the iid case are not enough in the MCMC context. Second, even when a CLT does hold, the asymptotic variance has a complex form and is difficult to estimate consistently. In this paper, we explain how to use regenerative simulation to overcome these problems. Actually, we consider a more general set up, where we assume that Markov chain samples from several probability densities, π1, …, πk, are available. We construct multiple-chain importance sampling estimators for which we obtain a CLT based on regeneration. We show that if the Markov chains converge to their respective target distributions at a geometric rate, then under moment conditions similar to those required in the iid case, the MCMC-based importance sampling estimator obeys a CLT. Furthermore, because the CLT is based on a regenerative process, there is a simple consistent estimator of the asymptotic variance. We illustrate the method with two applications in Bayesian sensitivity analysis. The first concerns one-way random effects models under different priors. The second involves Bayesian variable selection in linear regression, and for this application, importance sampling based on multiple chains enables an empirical Bayes approach to variable selection. PMID:28701855

  20. Honest Importance Sampling with Multiple Markov Chains.

    PubMed

    Tan, Aixin; Doss, Hani; Hobert, James P

    2015-01-01

    Importance sampling is a classical Monte Carlo technique in which a random sample from one probability density, π 1 , is used to estimate an expectation with respect to another, π . The importance sampling estimator is strongly consistent and, as long as two simple moment conditions are satisfied, it obeys a central limit theorem (CLT). Moreover, there is a simple consistent estimator for the asymptotic variance in the CLT, which makes for routine computation of standard errors. Importance sampling can also be used in the Markov chain Monte Carlo (MCMC) context. Indeed, if the random sample from π 1 is replaced by a Harris ergodic Markov chain with invariant density π 1 , then the resulting estimator remains strongly consistent. There is a price to be paid however, as the computation of standard errors becomes more complicated. First, the two simple moment conditions that guarantee a CLT in the iid case are not enough in the MCMC context. Second, even when a CLT does hold, the asymptotic variance has a complex form and is difficult to estimate consistently. In this paper, we explain how to use regenerative simulation to overcome these problems. Actually, we consider a more general set up, where we assume that Markov chain samples from several probability densities, π 1 , …, π k , are available. We construct multiple-chain importance sampling estimators for which we obtain a CLT based on regeneration. We show that if the Markov chains converge to their respective target distributions at a geometric rate, then under moment conditions similar to those required in the iid case, the MCMC-based importance sampling estimator obeys a CLT. Furthermore, because the CLT is based on a regenerative process, there is a simple consistent estimator of the asymptotic variance. We illustrate the method with two applications in Bayesian sensitivity analysis. The first concerns one-way random effects models under different priors. The second involves Bayesian variable selection in linear regression, and for this application, importance sampling based on multiple chains enables an empirical Bayes approach to variable selection.

  1. Characterization of the volatile components in green tea by IRAE-HS-SPME/GC-MS combined with multivariate analysis.

    PubMed

    Yang, Yan-Qin; Yin, Hong-Xu; Yuan, Hai-Bo; Jiang, Yong-Wen; Dong, Chun-Wang; Deng, Yu-Liang

    2018-01-01

    In the present work, a novel infrared-assisted extraction coupled to headspace solid-phase microextraction (IRAE-HS-SPME) followed by gas chromatography-mass spectrometry (GC-MS) was developed for rapid determination of the volatile components in green tea. The extraction parameters such as fiber type, sample amount, infrared power, extraction time, and infrared lamp distance were optimized by orthogonal experimental design. Under optimum conditions, a total of 82 volatile compounds in 21 green tea samples from different geographical origins were identified. Compared with classical water-bath heating, the proposed technique has remarkable advantages of considerably reducing the analytical time and high efficiency. In addition, an effective classification of green teas based on their volatile profiles was achieved by partial least square-discriminant analysis (PLS-DA) and hierarchical clustering analysis (HCA). Furthermore, the application of a dual criterion based on the variable importance in the projection (VIP) values of the PLS-DA models and on the category from one-way univariate analysis (ANOVA) allowed the identification of 12 potential volatile markers, which were considered to make the most important contribution to the discrimination of the samples. The results suggest that IRAE-HS-SPME/GC-MS technique combined with multivariate analysis offers a valuable tool to assess geographical traceability of different tea varieties.

  2. Risk factors and biofilm detection on central venous catheters of patients attended at tertiary hospital.

    PubMed

    Pérez-Zárate, Pamela; Aragón-Piña, Antonio; Soria-Guerra, Ruth Elena; González-Amaro, Ana María; Pérez-Urizar, José; Pérez-González, Luis Fernando; Martinez-Gutierrez, Fidel

    2015-11-01

    To determinate the significance of risk factors with the presence of biofilm on catheters of patients attended at tertiary hospital cares. A total of 126 patients were included, data collection by observing the handling of the CVC, clinical history and microbiological isolation methods of CVCs tips (Roll-plate, sonication and scanning electron microscopy) were evaluated. Certain factors, such as the lack of proper hand washing, the use of primary barriers and preparing medications in the same hospital service, showed an important relationship between biofilm formation in CVCs. The sonication method presented that most of the samples had isolation of multispecies 29 samples (64%); in contrast with the roll-plate method, just one sample (3%) was isolated. The importance of the strict aseptic techniques of insertion and of the handlings of CVC was highlighted, the failure of both techniques was related to the biofilm formation and was evidenced using the scanning electron microscopy. Since this tool is not available in most hospitals, we present the correlation of those evidences with other standard microbiological methods and risk factors, which are necessary for the sensible detection of the different steps of the biofilm formation on CVC and their correct interpretation with clinical evidences. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Characterization of the volatile components in green tea by IRAE-HS-SPME/GC-MS combined with multivariate analysis

    PubMed Central

    Yin, Hong-Xu; Yuan, Hai-Bo; Jiang, Yong-Wen; Dong, Chun-Wang; Deng, Yu-Liang

    2018-01-01

    In the present work, a novel infrared-assisted extraction coupled to headspace solid-phase microextraction (IRAE-HS-SPME) followed by gas chromatography-mass spectrometry (GC-MS) was developed for rapid determination of the volatile components in green tea. The extraction parameters such as fiber type, sample amount, infrared power, extraction time, and infrared lamp distance were optimized by orthogonal experimental design. Under optimum conditions, a total of 82 volatile compounds in 21 green tea samples from different geographical origins were identified. Compared with classical water-bath heating, the proposed technique has remarkable advantages of considerably reducing the analytical time and high efficiency. In addition, an effective classification of green teas based on their volatile profiles was achieved by partial least square-discriminant analysis (PLS-DA) and hierarchical clustering analysis (HCA). Furthermore, the application of a dual criterion based on the variable importance in the projection (VIP) values of the PLS-DA models and on the category from one-way univariate analysis (ANOVA) allowed the identification of 12 potential volatile markers, which were considered to make the most important contribution to the discrimination of the samples. The results suggest that IRAE-HS-SPME/GC-MS technique combined with multivariate analysis offers a valuable tool to assess geographical traceability of different tea varieties. PMID:29494626

  4. Search for life on Mars: Evaluation of techniques

    NASA Technical Reports Server (NTRS)

    Schwartz, D. E.; Mancinelli, R. L.; White, M. R.

    1995-01-01

    An important question for exobiology is, did life evolve on Mars? To answer this question, experiments must be conducted on the martian surface. Given current mission constraints on mass, power, and volume, these experiments can only be performed using proposed analytical techniques such as: electron microscopy, X-ray fluorescence, X-ray diffraction, a-proton backscatter, g-ray spectrometry, differential thermal analysis, differential scanning calorimetry, pyrolysis gas chromatography, mass spectrometry, and specific element detectors. Using prepared test samples consisting of 1% organic matter (bovine serum albumin) in palagonite and a mixture of palagonite, clays, iron oxides, and evaporites, it was determined that a combination of X-ray diffraction and differential thermal analysis coupled with gas chromatography provides the best insight into the chemistry, mineralogy, and geological history of the samples.

  5. Search for life on Mars: evaluation of techniques.

    PubMed

    Schwartz, D E; Mancinelli, R L; White, M R

    1995-03-01

    An important question for exobiology is, did life evolve on Mars? To answer this question, experiments must be conducted on the martian surface. Given current mission constraints on mass, power, and volume, these experiments can only be performed using proposed analytical techniques such as: electron microscopy, X-ray fluorescence, X-ray diffraction, alpha-proton backscatter, gamma-ray spectrometry, differential thermal analysis, differential scanning calorimetry, pyrolysis gas chromatography, mass spectrometry, and specific element detectors. Using prepared test samples consisting of 1% organic matter (bovine serum albumin) in palagonite and a mixture of palagonite, clays, iron oxides, and evaporites, it was determined that a combination of X-ray diffraction and differential thermal analysis coupled with gas chromatography provides the best insight into the chemistry, mineralogy, and geological history of the samples.

  6. Associated with aerospace vehicles development of methodologies for the estimation of thermal properties

    NASA Technical Reports Server (NTRS)

    Scott, Elaine P.

    1994-01-01

    Thermal stress analyses are an important aspect in the development of aerospace vehicles at NASA-LaRC. These analyses require knowledge of the temperature distributions within the vehicle structures which consequently necessitates the need for accurate thermal property data. The overall goal of this ongoing research effort is to develop methodologies for the estimation of the thermal property data needed to describe the temperature responses of these complex structures. The research strategy undertaken utilizes a building block approach. The idea here is to first focus on the development of property estimation methodologies for relatively simple conditions, such as isotropic materials at constant temperatures, and then systematically modify the technique for the analysis of more and more complex systems, such as anisotropic multi-component systems. The estimation methodology utilized is a statistically based method which incorporates experimental data and a mathematical model of the system. Several aspects of this overall research effort were investigated during the time of the ASEE summer program. One important aspect involved the calibration of the estimation procedure for the estimation of the thermal properties through the thickness of a standard material. Transient experiments were conducted using a Pyrex standard at various temperatures, and then the thermal properties (thermal conductivity and volumetric heat capacity) were estimated at each temperature. Confidence regions for the estimated values were also determined. These results were then compared to documented values. Another set of experimental tests were conducted on carbon composite samples at different temperatures. Again, the thermal properties were estimated for each temperature, and the results were compared with values obtained using another technique. In both sets of experiments, a 10-15 percent off-set between the estimated values and the previously determined values was found. Another effort was related to the development of the experimental techniques. Initial experiments required a resistance heater placed between two samples. The design was modified such that the heater was placed on the surface of only one sample, as would be necessary in the analysis of built up structures. Experiments using the modified technique were conducted on the composite sample used previously at different temperatures. The results were within 5 percent of those found using two samples. Finally, an initial heat transfer analysis, including conduction, convection and radiation components, was completed on a titanium sandwich structural sample. Experiments utilizing this sample are currently being designed and will be used to first estimate the material's effective thermal conductivity and later to determine the properties associated with each individual heat transfer component.

  7. Fast, reagentless and reliable screening of "white powders" during the bioterrorism hoaxes.

    PubMed

    Włodarski, Maksymilian; Kaliszewski, Miron; Trafny, Elżbieta Anna; Szpakowska, Małgorzata; Lewandowski, Rafał; Bombalska, Aneta; Kwaśny, Mirosław; Kopczyński, Krzysztof; Mularczyk-Oliwa, Monika

    2015-03-01

    The classification of dry powder samples is an important step in managing the consequences of terrorist incidents. Fluorescence decays of these samples (vegetative bacteria, bacterial endospores, fungi, albumins and several flours) were measured with stroboscopic technique using an EasyLife LS system PTI. Three pulsed nanosecond LED sources, generating 280, 340 and 460nm were employed for samples excitation. The usefulness of a new 460nm light source for fluorescence measurements of dry microbial cells has been demonstrated. The principal component analysis (PCA) and hierarchical cluster analysis (HCA) have been used for classification of dry biological samples. It showed that the single excitation wavelength was not sufficient for differentiation of biological samples of diverse origin. However, merging fluorescence decays from two or three excitation wavelengths allowed classification of these samples. An experimental setup allowing the practical implementation of this method for the real time fluorescence decay measurement was designed. It consisted of the LED emitting nanosecond pulses at 280nm and two fast photomultiplier tubes (PMTs) for signal detection in two fluorescence bands simultaneously. The positive results of the dry powder samples measurements confirmed that the fluorescence decay-based technique could be a useful tool for fast classification of the suspected "white powders" performed by the first responders. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. A comparative test of the investigator as a variable in aging quail

    USGS Publications Warehouse

    Rosene, W.; Fitch, F.

    1956-01-01

    To test the reliability of current techniques, five biologists appraised the ages of 200 quail from a random sample of wings collected during the 1952-53 hunting season in Alabama. Attempt was made to distinguish adults from juveniles, to ascertain the stage of post-nuptial and post-juvenile molts, and to estimate the age of juveniles according to days or weeks. Three 'problem' wings in this sample had molt characteristics somewhat eauallv divided between adult and juvenile classes; two wings called 'questionable' had all molt characteristics except one of either age group. A 3.5 per cent disparity occurred between investigators in their classification of adult and juvenile age groups. This included not only 'problem' and 'questionable' wings, but also 'obvious errors.' Individual differences were greater than 3.5 per cent but cancelled out. This study emphasizes the need of working with large samples of birds of a known age in order to know more concerning molt variations. Until aging techniques can be refined, it is believed that investigators should be fully familiar with existing methods and their weaknesses. Also, it appears important that reports on aging should indicate clearly the techniques used.

  9. Age and growth of rock bass in eastern Lake Ontario

    USGS Publications Warehouse

    Wolfert, David R.

    1980-01-01

    To test the reliability of current techniques, five biologists appraised the ages of 200 quail from a random sample of wings collected during the 1952-53 hunting season in Alabama. Attempt was made to distinguish adults from juveniles, to ascertain the stage of post-nuptial and post-juvenile molts, and to estimate the age of juveniles according to days or weeks. Three 'problem' wings in this sample had molt characteristics somewhat eauallv divided between adult and juvenile classes; two wings called 'questionable' had all molt characteristics except one of either age group. A 3.5 per cent disparity occurred between investigators in their classification of adult and juvenile age groups. This included not only 'problem' and 'questionable' wings, but also 'obvious errors.' Individual differences were greater than 3.5 per cent but cancelled out. This study emphasizes the need of working with large samples of birds of a known age in order to know more concerning molt variations. Until aging techniques can be refined, it is believed that investigators should be fully familiar with existing methods and their weaknesses. Also, it appears important that reports on aging should indicate clearly the techniques used.

  10. [Theoretical and methodological uses of research in Social and Human Sciences in Health].

    PubMed

    Deslandes, Suely Ferreira; Iriart, Jorge Alberto Bernstein

    2012-12-01

    The current article aims to map and critically reflect on the current theoretical and methodological uses of research in the subfield of social and human sciences in health. A convenience sample was used to select three Brazilian public health journals. Based on a reading of 1,128 abstracts published from 2009 to 2010, 266 articles were selected that presented the empirical base of research stemming from social and human sciences in health. The sample was classified thematically as "theoretical/ methodological reference", "study type/ methodological design", "analytical categories", "data production techniques", and "analytical procedures". We analyze the sample's emic categories, drawing on the authors' literal statements. All the classifications and respective variables were tabulated in Excel. Most of the articles were self-described as qualitative and used more than one data production technique. There was a wide variety of theoretical references, in contrast with the almost total predominance of a single type of data analysis (content analysis). In several cases, important gaps were identified in expounding the study methodology and instrumental use of the qualitative research techniques and methods. However, the review did highlight some new objects of study and innovations in theoretical and methodological approaches.

  11. Collective Behavior of Water on Platinum

    NASA Astrophysics Data System (ADS)

    Limmer, David; Willard, Adam; Chandler, David

    2012-02-01

    We present the results of molecular dynamics simulations of a interface between water and a platinum electrode. Using importance sampling techniques we probe a variety of collective phenomenon that emerge at the interface. We consider platinum electrodes with two different geometries and discuss how different behaviors result from a competition between geometrical frustration and favorable local interactions.

  12. Exposomics research using suspect screening and non-targeted analysis methods and tools at the U.S. Environmental Protection Agency (ASMS Presentation)

    EPA Science Inventory

    High-resolution mass spectrometry (HRMS) is used for suspect screening (SSA) and non-targeted analysis (NTA) in an attempt to characterize xenobiotic chemicals in various samples broadly and efficiently. These important techniques aid characterization of the exposome, the totalit...

  13. Chemical compositions of dissolved organic matter from various sources as characterized by solid-state NMR

    USDA-ARS?s Scientific Manuscript database

    Dissolved organic matter (DOM) in surface waters plays an important role in biogeochemical and ecological processes. This study used solid-state NMR techniques to explore the molecular signatures of riverine DOM in relation to its point and nonpoint sources. DOM samples were isolated from (1) two st...

  14. Implementability of Benchmarking (Comparative) Technique in Sports Enterprises (Sample Elazig)

    ERIC Educational Resources Information Center

    Altungul, Oguzhan; Demirag, Resat

    2017-01-01

    Increasing competition in domestic and foreign markets in the globalizing world and increasing quality expectations of customers have led enterprises to develop and implement a range of different quality considerations in order to remain competitive or to increase competitive power. One of the most important of these approaches is called…

  15. Antimicrobial Susceptibility of Tinea Capitis in Children from Egypt.

    PubMed

    Doss, Reham William; El-Rifaie, Abdel-Aziz; Radi, Nagla; El-Sherif, Aya Yehia

    2018-01-01

    Dermatophytic fungi of genera Trichophyton and Microsporum are the most important fungal species causing tinea capitis. Choice of treatment for tinea capitis is determined by the species of fungus. The aim of the study was to investigate the most prevalent fungal species causing tinea capitis in children from Egypt and the most useful antifungal agent for treatment. A total of 100 patients diagnosed clinically with tinea capitis were included in the study. Samples were collected and sent to the microbiology and immunology laboratory for sample processing and fungal identification by routine laboratory techniques. A study of antifungal susceptibility to chosen antifungal medications (fluconazole, ketoconazole, clotrimazole, miconazole, amphotericin, caspofungin, itraconazole, terbinafine, and griseofulvin) was done by minimum inhibitory concentration technique. Our analysis revealed that Microsporum canis is the most commonly isolated strain. Amphotericin was the most effective antifungal agent followed by terbinafine. The most sensitive strain to fluconazole and griseofulvin is Microsporum gypseum , while Microsporum audouinii was mostly responsive to terbinafine. Identification and evaluation of the antifungal susceptibility of the pathogenic species in a certain geographic region is important to achieve a good clinical response.

  16. Deterministic alternatives to the full configuration interaction quantum Monte Carlo method for strongly correlated systems

    NASA Astrophysics Data System (ADS)

    Tubman, Norm; Whaley, Birgitta

    The development of exponential scaling methods has seen great progress in tackling larger systems than previously thought possible. One such technique, full configuration interaction quantum Monte Carlo, allows exact diagonalization through stochastically sampling of determinants. The method derives its utility from the information in the matrix elements of the Hamiltonian, together with a stochastic projected wave function, which are used to explore the important parts of Hilbert space. However, a stochastic representation of the wave function is not required to search Hilbert space efficiently and new deterministic approaches have recently been shown to efficiently find the important parts of determinant space. We shall discuss the technique of Adaptive Sampling Configuration Interaction (ASCI) and the related heat-bath Configuration Interaction approach for ground state and excited state simulations. We will present several applications for strongly correlated Hamiltonians. This work was supported through the Scientific Discovery through Advanced Computing (SciDAC) program funded by the U.S. Department of Energy, Office of Science, Advanced Scientific Computing Research and Basic Energy Sciences.

  17. Monitoring Interfacial Lipid Oxidation in Oil-in-Water Emulsions Using Spatially Resolved Optical Techniques.

    PubMed

    Banerjee, Chiranjib; Westberg, Michael; Breitenbach, Thomas; Bregnhøj, Mikkel; Ogilby, Peter R

    2017-06-06

    The oxidation of lipids is an important phenomenon with ramifications for disciplines that range from food science to cell biology. The development and characterization of tools and techniques to monitor lipid oxidation are thus relevant. Of particular significance in this regard are tools that facilitate the study of oxidations at interfaces in heterogeneous samples (e.g., oil-in-water emulsions, cell membranes). In this article, we establish a proof-of-principle for methods to initiate and then monitor such oxidations with high spatial resolution. The experiments were performed using oil-in-water emulsions of polyunsaturated fatty acids (PUFAs) prepared from cod liver oil. We produced singlet oxygen at a point near the oil-water interface of a given PUFA droplet in a spatially localized two-photon photosensitized process. We then followed the oxidation reactions initiated by this process with the fluorescence-based imaging technique of structured illumination microscopy (SIM). We conclude that the approach reported herein has attributes well-suited to the study of lipid oxidation in heterogeneous samples.

  18. Portable Infrared Laser Spectroscopy for On-site Mycotoxin Analysis.

    PubMed

    Sieger, Markus; Kos, Gregor; Sulyok, Michael; Godejohann, Matthias; Krska, Rudolf; Mizaikoff, Boris

    2017-03-09

    Mycotoxins are toxic secondary metabolites of fungi that spoil food, and severely impact human health (e.g., causing cancer). Therefore, the rapid determination of mycotoxin contamination including deoxynivalenol and aflatoxin B 1 in food and feed samples is of prime interest for commodity importers and processors. While chromatography-based techniques are well established in laboratory environments, only very few (i.e., mostly immunochemical) techniques exist enabling direct on-site analysis for traders and manufacturers. In this study, we present MYCOSPEC - an innovative approach for spectroscopic mycotoxin contamination analysis at EU regulatory limits for the first time utilizing mid-infrared tunable quantum cascade laser (QCL) spectroscopy. This analysis technique facilitates on-site mycotoxin analysis by combining QCL technology with GaAs/AlGaAs thin-film waveguides. Multivariate data mining strategies (i.e., principal component analysis) enabled the classification of deoxynivalenol-contaminated maize and wheat samples, and of aflatoxin B 1 affected peanuts at EU regulatory limits of 1250 μg kg -1 and 8 μg kg -1 , respectively.

  19. Portable Infrared Laser Spectroscopy for On-site Mycotoxin Analysis

    PubMed Central

    Sieger, Markus; Kos, Gregor; Sulyok, Michael; Godejohann, Matthias; Krska, Rudolf; Mizaikoff, Boris

    2017-01-01

    Mycotoxins are toxic secondary metabolites of fungi that spoil food, and severely impact human health (e.g., causing cancer). Therefore, the rapid determination of mycotoxin contamination including deoxynivalenol and aflatoxin B1 in food and feed samples is of prime interest for commodity importers and processors. While chromatography-based techniques are well established in laboratory environments, only very few (i.e., mostly immunochemical) techniques exist enabling direct on-site analysis for traders and manufacturers. In this study, we present MYCOSPEC - an innovative approach for spectroscopic mycotoxin contamination analysis at EU regulatory limits for the first time utilizing mid-infrared tunable quantum cascade laser (QCL) spectroscopy. This analysis technique facilitates on-site mycotoxin analysis by combining QCL technology with GaAs/AlGaAs thin-film waveguides. Multivariate data mining strategies (i.e., principal component analysis) enabled the classification of deoxynivalenol-contaminated maize and wheat samples, and of aflatoxin B1 affected peanuts at EU regulatory limits of 1250 μg kg−1 and 8 μg kg−1, respectively. PMID:28276454

  20. Uncertainty Quantification and Statistical Convergence Guidelines for PIV Data

    NASA Astrophysics Data System (ADS)

    Stegmeir, Matthew; Kassen, Dan

    2016-11-01

    As Particle Image Velocimetry has continued to mature, it has developed into a robust and flexible technique for velocimetry used by expert and non-expert users. While historical estimates of PIV accuracy have typically relied heavily on "rules of thumb" and analysis of idealized synthetic images, recently increased emphasis has been placed on better quantifying real-world PIV measurement uncertainty. Multiple techniques have been developed to provide per-vector instantaneous uncertainty estimates for PIV measurements. Often real-world experimental conditions introduce complications in collecting "optimal" data, and the effect of these conditions is important to consider when planning an experimental campaign. The current work utilizes the results of PIV Uncertainty Quantification techniques to develop a framework for PIV users to utilize estimated PIV confidence intervals to compute reliable data convergence criteria for optimal sampling of flow statistics. Results are compared using experimental and synthetic data, and recommended guidelines and procedures leveraging estimated PIV confidence intervals for efficient sampling for converged statistics are provided.

  1. Portable Infrared Laser Spectroscopy for On-site Mycotoxin Analysis

    NASA Astrophysics Data System (ADS)

    Sieger, Markus; Kos, Gregor; Sulyok, Michael; Godejohann, Matthias; Krska, Rudolf; Mizaikoff, Boris

    2017-03-01

    Mycotoxins are toxic secondary metabolites of fungi that spoil food, and severely impact human health (e.g., causing cancer). Therefore, the rapid determination of mycotoxin contamination including deoxynivalenol and aflatoxin B1 in food and feed samples is of prime interest for commodity importers and processors. While chromatography-based techniques are well established in laboratory environments, only very few (i.e., mostly immunochemical) techniques exist enabling direct on-site analysis for traders and manufacturers. In this study, we present MYCOSPEC - an innovative approach for spectroscopic mycotoxin contamination analysis at EU regulatory limits for the first time utilizing mid-infrared tunable quantum cascade laser (QCL) spectroscopy. This analysis technique facilitates on-site mycotoxin analysis by combining QCL technology with GaAs/AlGaAs thin-film waveguides. Multivariate data mining strategies (i.e., principal component analysis) enabled the classification of deoxynivalenol-contaminated maize and wheat samples, and of aflatoxin B1 affected peanuts at EU regulatory limits of 1250 μg kg-1 and 8 μg kg-1, respectively.

  2. Comparative study of radiometric and calorimetric methods for total hemispherical emissivity measurements

    NASA Astrophysics Data System (ADS)

    Monchau, Jean-Pierre; Hameury, Jacques; Ausset, Patrick; Hay, Bruno; Ibos, Laurent; Candau, Yves

    2018-05-01

    Accurate knowledge of infrared emissivity is important in applications such as surface temperature measurements by infrared thermography or thermal balance for building walls. A comparison of total hemispherical emissivity measurement was performed by two laboratories: the Laboratoire National de Métrologie et d'Essais (LNE) and the Centre d'Études et de Recherche en Thermique, Environnement et Systèmes (CERTES). Both laboratories performed emissivity measurements on four samples, chosen to cover a large range of emissivity values and angular reflectance behaviors. The samples were polished aluminum (highly specular, low emissivity), bulk PVC (slightly specular, high emissivity), sandblasted aluminum (diffuse surface, medium emissivity), and aluminum paint (slightly specular surface, medium emissivity). Results obtained using five measurement techniques were compared. LNE used a calorimetric method for direct total hemispherical emissivity measurement [1], an absolute reflectometric measurement method [2], and a relative reflectometric measurement method. CERTES used two total hemispherical directional reflectometric measurement methods [3, 4]. For indirect techniques by reflectance measurements, the total hemispherical emissivity values were calculated from directional hemispherical reflectance measurement results using spectral integration when required and directional to hemispherical extrapolation. Results were compared, taking into account measurement uncertainties; an added uncertainty was introduced to account for heterogeneity over the surfaces of the samples and between samples. All techniques gave large relative uncertainties for a low emissive and very specular material (polished aluminum), and results were quite scattered. All the indirect techniques by reflectance measurement gave results within ±0.01 for a high emissivity material. A commercial aluminum paint appears to be a good candidate for producing samples with medium level of emissivity (about 0.4) and with good uniformity of emissivity values (within ±0.015).

  3. The Development of Metabolomic Sampling Procedures for Pichia pastoris, and Baseline Metabolome Data

    PubMed Central

    Tredwell, Gregory D.; Edwards-Jones, Bryn; Leak, David J.; Bundy, Jacob G.

    2011-01-01

    Metabolic profiling is increasingly being used to investigate a diverse range of biological questions. Due to the rapid turnover of intracellular metabolites it is important to have reliable, reproducible techniques for sampling and sample treatment. Through the use of non-targeted analytical techniques such as NMR and GC-MS we have performed a comprehensive quantitative investigation of sampling techniques for Pichia pastoris. It was clear that quenching metabolism using solutions based on the standard cold methanol protocol caused some metabolite losses from P. pastoris cells. However, these were at a low level, with the NMR results indicating metabolite increases in the quenching solution below 5% of their intracellular level for 75% of metabolites identified; while the GC-MS results suggest a slightly higher level with increases below 15% of their intracellular values. There were subtle differences between the four quenching solutions investigated but broadly, they all gave similar results. Total culture extraction of cells + broth using high cell density cultures typical of P. pastoris fermentations, was an efficient sampling technique for NMR analysis and provided a gold standard of intracellular metabolite levels; however, salts in the media affected the GC-MS analysis. Furthermore, there was no benefit in including an additional washing step in the quenching process, as the results were essentially identical to those obtained just by a single centrifugation step. We have identified the major high-concentration metabolites found in both the extra- and intracellular locations of P. pastoris cultures by NMR spectroscopy and GC-MS. This has provided us with a baseline metabolome for P. pastoris for future studies. The P. pastoris metabolome is significantly different from that of Saccharomyces cerevisiae, with the most notable difference being the production of high concentrations of arabitol by P. pastoris. PMID:21283710

  4. Varietal discrimination of hop pellets by near and mid infrared spectroscopy.

    PubMed

    Machado, Julio C; Faria, Miguel A; Ferreira, Isabel M P L V O; Páscoa, Ricardo N M J; Lopes, João A

    2018-04-01

    Hop is one of the most important ingredients of beer production and several varieties are commercialized. Therefore, it is important to find an eco-real-time-friendly-low-cost technique to distinguish and discriminate hop varieties. This paper describes the development of a method based on vibrational spectroscopy techniques, namely near- and mid-infrared spectroscopy, for the discrimination of 33 commercial hop varieties. A total of 165 samples (five for each hop variety) were analysed by both techniques. Principal component analysis, hierarchical cluster analysis and partial least squares discrimination analysis were the chemometric tools used to discriminate positively the hop varieties. After optimizing the spectral regions and pre-processing methods a total of 94.2% and 96.6% correct hop varieties discrimination were obtained for near- and mid-infrared spectroscopy, respectively. The results obtained demonstrate the suitability of these vibrational spectroscopy techniques to discriminate different hop varieties and consequently their potential to be used as an authenticity tool. Compared with the reference procedures normally used for hops variety discrimination these techniques are quicker, cost-effective, non-destructive and eco-friendly. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. A Novel Hybrid Ultramicrotomy/FIB-SEM Technique: Preparation of Serial Electron-Transparent Thin Sections of a Hayabusa Grain

    NASA Technical Reports Server (NTRS)

    Berger, Eve L.; Keller, Lindsay P.

    2014-01-01

    The Japanese space agency's (JAXA) Hayabusa mission returned the first particulate samples (typically <100micron) from the surface of an asteroid (25143 Itokawa). These precious samples provide important insights into early Solar System processes, but their sizes pose tremendous challenges to coordinated analysis using a variety of nano- and micro-beam techniques. The ability to glean maximal information from individual particles has become increasingly important and depends critically on sample preparation. We developed a hybrid technique combining traditional ultramicrotomy with focused ion beam (FIB) techniques, allowing for more thorough in situ investigations of grain surfaces and interiors. Using this method, we increase the number of FIB-prepared sections that can be recovered from a particle with dimensions on the order of tens of microns. These sections can be subsequently analyzed using a variety of analytical techniques. Particle RA-QD02-0211 is a approx. 40×40×20 micron particle from Itokawa containing olivine and Fe sulfides. It was embedded in low viscosity epoxy and partly sectioned to a depth of approx 10 micron; sections are placed on Cu grids with thin amorphous films for transmission electron microscope (TEM) analyses. With the sample surface partly exposed, the epoxy bullet is trimmed to a height of approx. 5mm to accommodate the allowable dimensions for FIB work (FEI Quanta 600 3D dual beam FIB-SEM). Using a diamond trim knife, the epoxy surrounding the grain is removed on 3 sides (to within a few microns of the grain); the depth of material removed extends well below the bottom of the particle. The sample is attached to an SEM pin mount, the epoxy coated with conductive paint, and the entire assembly coated with approx. 40nm of carbon to eliminate sample charging during FIB work. A protective carbon cap is placed according to the plan for the 15 FIB sections. The central 'spine' of the cap runs perpendicular to the front of the sample, and the 'ribs' protruding from either side run parallel. Each rib indicates the location of a planned FIB section, and the spine contains the final two planned sections. We use a cap with a 4 micron-wide spine and 2micron-wide ribs that have ?3.5 micron of space between them (narrower cuts result in too much re-deposition of material inside the trenches). Using a 30kV, 3nA ion-beam we expose the front surface of the grain and commence milling trenches between sections. Rather than using the typical C-cut to prepare the sample for lift-out, an L-cut is used instead, leaving the sample connected by an interior tab. tab. Sections are lifted out, attached to TEM grids and thinned to electron transparency. TEM analyses show that our hybrid technique preserves both interior and edge features, including surface modifications from exposure to the space environment, such as damaged rims that form in response to solar wind implantation effects and adhering grains. In addition, the FIB sections provide larger areas that are free of fractures and chatter effects in comparison to the microtome thin sections, thus enabling more accurate measurements of solar flare particle track densities that are used to determine the surface exposure age of the particles.

  6. Analysis of student attitudes towards e-learning using Fishbein Multiattribute approach

    NASA Astrophysics Data System (ADS)

    Jasuli

    2018-01-01

    This research aimed to know students’ attitudes toward e-learning and to determine what attributes were considered to be dominant by students toward the use of e-learning. The research population was all postgraduate students in the 2016 academic year at Universitas Negeri Surabaya. The sampling technique is using nonprobability sampling and purposive sampling with the sample totaled 100 respondents. The research instrument is using questionnaire with semantic differential scale. The models used to analyze is multi-attribute Fishbein model. The findings indicated that student attitudes toward e-learning are positive and easy accessibility which is considered as the most important attribute by students toward the use of e-learning.

  7. Field emission scanning electron microscopy (FE-SEM) as an approach for nanoparticle detection inside cells.

    PubMed

    Havrdova, M; Polakova, K; Skopalik, J; Vujtek, M; Mokdad, A; Homolkova, M; Tucek, J; Nebesarova, J; Zboril, R

    2014-12-01

    When developing new nanoparticles for bio-applications, it is important to fully characterize the nanoparticle's behavior in biological systems. The most common techniques employed for mapping nanoparticles inside cells include transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM). These techniques entail passing an electron beam through a thin specimen. STEM or TEM imaging is often used for the detection of nanoparticles inside cellular organelles. However, lengthy sample preparation is required (i.e., fixation, dehydration, drying, resin embedding, and cutting). In the present work, a new matrix (FTO glass) for biological samples was used and characterized by field emission scanning electron microscopy (FE-SEM) to generate images comparable to those obtained by TEM. Using FE-SEM, nanoparticle images were acquired inside endo/lysosomes without disruption of the cellular shape. Furthermore, the initial steps of nanoparticle incorporation into the cells were captured. In addition, the conductive FTO glass endowed the sample with high stability under the required accelerating voltage. Owing to these features of the sample, further analyses could be performed (material contrast and energy-dispersive X-ray spectroscopy (EDS)), which confirmed the presence of nanoparticles inside the cells. The results showed that FE-SEM can enable detailed characterization of nanoparticles in endosomes without the need for contrast staining or metal coating of the sample. Images showing the intracellular distribution of nanoparticles together with cellular morphology can give important information on the biocompatibility and demonstrate the potential of nanoparticle utilization in medicine. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Bayesian linkage and segregation analysis: factoring the problem.

    PubMed

    Matthysse, S

    2000-01-01

    Complex segregation analysis and linkage methods are mathematical techniques for the genetic dissection of complex diseases. They are used to delineate complex modes of familial transmission and to localize putative disease susceptibility loci to specific chromosomal locations. The computational problem of Bayesian linkage and segregation analysis is one of integration in high-dimensional spaces. In this paper, three available techniques for Bayesian linkage and segregation analysis are discussed: Markov Chain Monte Carlo (MCMC), importance sampling, and exact calculation. The contribution of each to the overall integration will be explicitly discussed.

  9. Quantum-optical coherence tomography with classical light.

    PubMed

    Lavoie, J; Kaltenbaek, R; Resch, K J

    2009-03-02

    Quantum-optical coherence tomography (Q-OCT) is an interferometric technique for axial imaging offering several advantages over conventional methods. Chirped-pulse interferometry (CPI) was recently demonstrated to exhibit all of the benefits of the quantum interferometer upon which Q-OCT is based. Here we use CPI to measure axial interferograms to profile a sample accruing the important benefits of Q-OCT, including automatic dispersion cancellation, but with 10 million times higher signal. Our technique solves the artifact problem in Q-OCT and highlights the power of classical correlation in optical imaging.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hudson, W.G.

    Scapteriscus vicinus is the most important pest of turf and pasture grasses in Florida. This study develops a method of correlating sample results with true population density and provides the first quantitative information on spatial distribution and movement patterns of mole crickets. Three basic techniques for sampling mole crickets were compared: soil flushes, soil corer, and pitfall trapping. No statistical difference was found between the soil corer and soil flushing. Soil flushing was shown to be more sensitive to changes in population density than pitfall trapping. No technique was effective for sampling adults. Regression analysis provided a means of adjustingmore » for the effects of soil moisture and showed soil temperature to be unimportant in predicting efficiency of flush sampling. Cesium-137 was used to label females for subsequent location underground. Comparison of mean distance to nearest neighbor with the distance predicted by a random distribution model showed that the observed distance in the spring was significantly greater than hypothesized (Student's T-test, p < 0.05). Fall adult nearest neighbor distance was not different than predicted by the random distribution hypothesis.« less

  11. Towards the differentiation of non-treated and treated corundum minerals by ion-beam-induced luminescence and other complementary techniques.

    PubMed

    Calvo del Castillo, H; Deprez, N; Dupuis, T; Mathis, F; Deneckere, A; Vandenabeele, P; Calderón, T; Strivay, D

    2009-06-01

    Differentiation of treated and non-treated gemstones is a chief concern for major jewellery import companies. Low-quality corundum specimens coming from Asia appear to be often treated with heat, BeO or flux in order to enhance their properties as precious minerals. A set of corundum samples, rubies and sapphires from different origins, both treated and non-treated has been analysed at the Centre Européen d'Archéométrie, with ion-beam-induced luminescence (IBIL) and other complementary techniques such as Raman, proton-induced X-ray emission (PIXE), and proton-induced gamma-ray emission (PIGE). IBIL, also known as ionoluminescence, has been used before to detect impurities or defects inside synthetic materials and natural minerals; its use for the discrimination of gemstone simulants or synthetic analogues has been elsewhere discussed (Cavenago-Bignami Moneta, Gemología, Tomo I Piedras preciosas, perlas, corales, marfil. Ediciones Omega, Barcelona, 1991). PIXE has been frequently applied in the archaeometric field for material characterisation and provenance studies of minerals (Hughes, Ruby & sapphire. RWH Publishing, Fallbrook, 1997; Calvo del Castillo et al., Anal Bioanal Chem 387:869-878, 2007; Calligaro et al., NIM-B 189:320-327, 2002) and PIGE complements the elemental analysis by detecting light elements in these materials such as-and lighter than-sodium that cannot be identified with the PIXE technique (Sanchez et al., NIM-B 130:682-686, 1997; Emmett et al., Gems Gemology 39:84-135, 2003). The micro-Raman technique has also been used complementarily to ion beam analysis techniques for mineral characterisation (Novak et al., Appl Surf Sci 231-232:917-920, 2004). The aim of this study is to provide new means for systematic analysis of corundum gemstone-quality mineral, alternative to the traditional gemmologic methods; for this purpose, a Spanish jewellery import company supplied us with a number of natural corundum samples coming from different places (part of them treated as explained above). The PIXE elemental concentrations of the samples showed large quantities of calcium and lead in some cases that can be linked to treatment with fluxes or lead oxide. The plot of the chromium and iron concentration grouped the samples in various aggregates that corresponded to the different types of corundum analysed. Micro-Raman complemented the PIXE analysis corroborating the presence of lead oxides but the use of the PIGE technique was not successful for the detection of beryllium due to the low cross section of the nuclear reaction chosen for its identification. IBIL was capable of distinguishing between treated and non-treated samples of the same type based on the luminescent features of the materials.

  12. Prevalence and types of preanalytical error in hematology laboratory of a tertiary care hospital in South India.

    PubMed

    Arul, Pitchaikaran; Pushparaj, Magesh; Pandian, Kanmani; Chennimalai, Lingasamy; Rajendran, Karthika; Selvaraj, Eniya; Masilamani, Suresh

    2018-01-01

    An important component of laboratory medicine is preanalytical phase. Since laboratory report plays a major role in patient management, more importance should be given to the quality of laboratory tests. The present study was undertaken to find the prevalence and types of preanalytical errors at a tertiary care hospital in South India. In this cross-sectional study, a total of 118,732 samples ([62,474 outpatient department [OPD] and 56,258 inpatient department [IPD]) were received in hematology laboratory. These samples were analyzed for preanalytical errors such as misidentification, incorrect vials, inadequate samples, clotted samples, diluted samples, and hemolyzed samples. The overall prevalence of preanalytical errors found was 513 samples, which is 0.43% of the total number of samples received. The most common preanalytical error observed was inadequate samples followed by clotted samples. Overall frequencies (both OPD and IPD) of preanalytical errors such as misidentification, incorrect vials, inadequate samples, clotted samples, diluted samples, and hemolyzed samples were 0.02%, 0.05%, 0.2%, 0.12%, 0.02%, and 0.03%, respectively. The present study concluded that incorrect phlebotomy techniques due to lack of awareness is the main reason for preanalytical errors. This can be avoided by proper communication and coordination between laboratory and wards, proper training and continuing medical education programs for laboratory and paramedical staffs, and knowledge of the intervening factors that can influence laboratory results.

  13. Wavelength resolved neutron transmission analysis to identify single crystal particles in historical metallurgy

    NASA Astrophysics Data System (ADS)

    Barzagli, E.; Grazzi, F.; Salvemini, F.; Scherillo, A.; Sato, H.; Shinohara, T.; Kamiyama, T.; Kiyanagi, Y.; Tremsin, A.; Zoppi, Marco

    2014-07-01

    The phase composition and the microstructure of four ferrous Japanese arrows of the Edo period (17th-19th century) has been determined through two complementary neutron techniques: Position-sensitive wavelength-resolved neutron transmission analysis (PS-WRNTA) and time-of-flight neutron diffraction (ToF-ND). Standard ToF-ND technique has been applied by using the INES diffractometer at the ISIS pulsed neutron source in the UK, while the innovative PS-WRNTA one has been performed at the J-PARC neutron source on the BL-10 NOBORU beam line using the high spatial high time resolution neutron imaging detector. With ToF-ND we were able to reach information about the quantitative distribution of the metal and non-metal phases, the texture level, the strain level and the domain size of each of the samples, which are important parameters to gain knowledge about the technological level of the Japanese weapon. Starting from this base of data, the more complex PS-WRNTA has been applied to the same samples. This experimental technique exploits the presence of the so-called Bragg edges, in the time-of-flight spectrum of neutrons transmitted through crystalline materials, to map the microstructural properties of samples. The two techniques are non-invasive and can be easily applied to archaeometry for an accurate microstructure mapping of metal and ceramic artifacts.

  14. Development of non-destructive examination techniques for CFC-metal joints in annular geometry and their application to the manufacturing of plasma-facing components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Di Pietro, E.; Visca, E.; Orsini, A.

    1995-12-31

    The design of plasma-facing components for ITER, as for any of the envisaged next-step machines, relies heavily on the use of brazed junctions to couple armour materials to the heat sink and cooling tubes. Moreover, the typical number of brazed components and the envisaged effects of local overheating due to failure in a single brazed junction stress the importance of having a set of NDE techniques developed that can ensure the flawless quality of the joint. The qualification and application of two NDE techniques (ultrasonic and thermographic analysis) for inspection of CFC-to-metal joints is described with particular regard to themore » annular geometry typical of macroblock/monoblock solutions for divertor high-heat-flux components. The results of the eddy current inspection are not reported. The development has been focused specifically on the joint between carbon-fiber composite and TZM molybdenum alloy; techniques for the production of reference defect samples have been devised and a set of reference defect samples produced. The comparative results of the NDE inspections are reported and discussed, also on the basis of the destructive examination of the samples. The nature and size of relevant and detectable defects are discussed together with hints for a possible NDE strategy for divertor high-heat-flux components.« less

  15. RESPONDENT-DRIVEN SAMPLING AS MARKOV CHAIN MONTE CARLO

    PubMed Central

    GOEL, SHARAD; SALGANIK, MATTHEW J.

    2013-01-01

    Respondent-driven sampling (RDS) is a recently introduced, and now widely used, technique for estimating disease prevalence in hidden populations. RDS data are collected through a snowball mechanism, in which current sample members recruit future sample members. In this paper we present respondent-driven sampling as Markov chain Monte Carlo (MCMC) importance sampling, and we examine the effects of community structure and the recruitment procedure on the variance of RDS estimates. Past work has assumed that the variance of RDS estimates is primarily affected by segregation between healthy and infected individuals. We examine an illustrative model to show that this is not necessarily the case, and that bottlenecks anywhere in the networks can substantially affect estimates. We also show that variance is inflated by a common design feature in which sample members are encouraged to recruit multiple future sample members. The paper concludes with suggestions for implementing and evaluating respondent-driven sampling studies. PMID:19572381

  16. The application of microwave digestion in decomposing some refractory ore samples with solid fusion agent.

    PubMed

    Lu, Yan; Li, Gang; Liu, Wei; Yuan, Hongyan; Xiao, Dan

    2018-08-15

    It is known that most of the refractory ore are the basis of national economy and widely applied in various fields, however, the complexity of the chemical composition and the diversity of the crystallinity in the mineral phases make the sample pre-treatment of refractory ore still remains a challenge. In this work, the complete decomposition of the refractory ore sample can be achieved just by exposing the solid fusion agent and the refractory ore sample in the microwave irradiation environment for a few minutes, and induced by a drop of water. A digestion time of 15 min for 3.0 g solid fusion agent mixture of sodium peroxide/sodium carbonate (Na 2 O 2 /Na 2 CO 3 ) in a corundum crucible via microwave heating is sufficient to decompose 0.1 g refractory ore sample. An excellent microwave digestion solid agent should meet the following conditions, a good decomposition ability, an outstanding ability of absorbing microwave energy and converting it into heat quickly, a higher melting point than the decomposing temperature of the ore sample. In the research, the induction effect of water plays an important role for the microwave digestion. The energy which is released by the reaction of water and the solid fusion agent (Na 2 O 2 ) is the key to decompose refractory ore samples with solid fusion agent, which replenished the total energy required for the microwave digestion and made the microwave digestion completed successfully. This microwave digestion technique has good reproducibility and precision, RSD % for Mo, Fe, Ti, Cr and W in the refractory ore samples were all better than 6, except RSD % for Be of about 8 because of the influence of matrix-effect. Meanwhile, the analysis results of the elements in the refractory ore samples provided by the microwave digestion technique were all in good agreement with the analysis results provided by the traditional fusion method except for Cr in the mixture ore samples. In the study, the non-linear dependence of the electromagnetic and thermal properties of the solid fusion agent on temperature under microwave irradiation and the selective heating of microwave are fully applied in this simple microwave technique. Comparing to the traditional fusion decomposition method, this microwave digestion technique is a simple, economical, fast and energy-saving sample pre-treatment technique. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Coil Compression for Accelerated Imaging with Cartesian Sampling

    PubMed Central

    Zhang, Tao; Pauly, John M.; Vasanawala, Shreyas S.; Lustig, Michael

    2012-01-01

    MRI using receiver arrays with many coil elements can provide high signal-to-noise ratio and increase parallel imaging acceleration. At the same time, the growing number of elements results in larger datasets and more computation in the reconstruction. This is of particular concern in 3D acquisitions and in iterative reconstructions. Coil compression algorithms are effective in mitigating this problem by compressing data from many channels into fewer virtual coils. In Cartesian sampling there often are fully sampled k-space dimensions. In this work, a new coil compression technique for Cartesian sampling is presented that exploits the spatially varying coil sensitivities in these non-subsampled dimensions for better compression and computation reduction. Instead of directly compressing in k-space, coil compression is performed separately for each spatial location along the fully-sampled directions, followed by an additional alignment process that guarantees the smoothness of the virtual coil sensitivities. This important step provides compatibility with autocalibrating parallel imaging techniques. Its performance is not susceptible to artifacts caused by a tight imaging fieldof-view. High quality compression of in-vivo 3D data from a 32 channel pediatric coil into 6 virtual coils is demonstrated. PMID:22488589

  18. Multiple sensitive estimation and optimal sample size allocation in the item sum technique.

    PubMed

    Perri, Pier Francesco; Rueda García, María Del Mar; Cobo Rodríguez, Beatriz

    2018-01-01

    For surveys of sensitive issues in life sciences, statistical procedures can be used to reduce nonresponse and social desirability response bias. Both of these phenomena provoke nonsampling errors that are difficult to deal with and can seriously flaw the validity of the analyses. The item sum technique (IST) is a very recent indirect questioning method derived from the item count technique that seeks to procure more reliable responses on quantitative items than direct questioning while preserving respondents' anonymity. This article addresses two important questions concerning the IST: (i) its implementation when two or more sensitive variables are investigated and efficient estimates of their unknown population means are required; (ii) the determination of the optimal sample size to achieve minimum variance estimates. These aspects are of great relevance for survey practitioners engaged in sensitive research and, to the best of our knowledge, were not studied so far. In this article, theoretical results for multiple estimation and optimal allocation are obtained under a generic sampling design and then particularized to simple random sampling and stratified sampling designs. Theoretical considerations are integrated with a number of simulation studies based on data from two real surveys and conducted to ascertain the efficiency gain derived from optimal allocation in different situations. One of the surveys concerns cannabis consumption among university students. Our findings highlight some methodological advances that can be obtained in life sciences IST surveys when optimal allocation is achieved. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Sample Preparation for Electron Probe Microanalysis—Pushing the Limits

    PubMed Central

    Geller, Joseph D.; Engle, Paul D.

    2002-01-01

    There are two fundamental considerations in preparing samples for electron probe microanalysis (EPMA). The first one may seem obvious, but we often find it is overlooked. That is, the sample analyzed should be representative of the population from which it comes. The second is a direct result of the assumptions in the calculations used to convert x-ray intensity ratios, between the sample and standard, to concentrations. Samples originate from a wide range of sources. During their journey to being excited under the electron beam for the production of x rays there are many possibilities for sample alteration. Handling can contaminate samples by adding extraneous matter. In preparation, the various abrasives used in sizing the sample by sawing, grinding and polishing can embed themselves. The most accurate composition of a contaminated sample is, at best, not representative of the original sample; it is misleading. Our laboratory performs EPMA analysis on customer submitted samples and prepares over 250 different calibration standards including pure elements, compounds, alloys, glasses and minerals. This large variety of samples does not lend itself to mass production techniques, including automatic polishing. Our manual preparation techniques are designed individually for each sample. The use of automated preparation equipment does not lend itself to this environment, and is not included in this manuscript. The final step in quantitative electron probe microanalysis is the conversion of x-ray intensities ratios, known as the “k-ratios,” to composition (in mass fraction or atomic percent) and/or film thickness. Of the many assumptions made in the ZAF (where these letters stand for atomic number, absorption and fluorescence) corrections the localized geometry between the sample and electron beam, or takeoff angle, must be accurately known. Small angular errors can lead to significant errors in the final results. The sample preparation technique then becomes very important, and, under certain conditions, may even be the limiting factor in the analytical uncertainty budget. This paper considers preparing samples to get known geometries. It will not address the analysis of samples with irregular, unprepared surfaces or unknown geometries. PMID:27446757

  20. Mars sample return: Site selection and sample acquisition study

    NASA Technical Reports Server (NTRS)

    Nickle, N. (Editor)

    1980-01-01

    Various vehicle and mission options were investigated for the continued exploration of Mars; the cost of a minimum sample return mission was estimated; options and concepts were synthesized into program possibilities; and recommendations for the next Mars mission were made to the Planetary Program office. Specific sites and all relevant spacecraft and ground-based data were studied in order to determine: (1) the adequacy of presently available data for identifying landing sities for a sample return mission that would assure the acquisition of material from the most important geologic provinces of Mars; (2) the degree of surface mobility required to assure sample acquisition for these sites; (3) techniques to be used in the selection and drilling of rock a samples; and (4) the degree of mobility required at the two Viking sites to acquire these samples.

  1. Reduction of aflatoxin in rice by different cooking methods.

    PubMed

    Sani, Ali Mohamadi; Azizi, Eisa Gholampour; Salehi, Esmaeel Ataye; Rahimi, Khadije

    2014-07-01

    Rice (Oryza sativa Linn) is one of the basic diets in the north of Iran. The aim of present study was to detect total aflatoxin (AFT) in domestic and imported rice in Amol (in the north of Iran) and to evaluate the effect of different cooking methods on the levels of the toxin. For this purpose, 42 rice samples were collected from retail stores. The raw samples were analysed by enzyme-linked immunosorbent assay (ELISA) technique for toxin assessment and then submitted to two different cooking methods including traditional local method and in rice cooker. After treatment, AFT was determined. Results show that the average concentration of AFT in domestic and imported samples was 1.08 ± 0.02 and 1.89 ± 0.87 ppb, respectively, which is lower than national and European Union standards. The highest AFT reduction (24.8%) was observed when rice samples were cooked by rice cooker but the difference with local method was not statistically significant (p > 0.05). © The Author(s) 2012.

  2. Critical review of the United Kingdom's "gold standard" survey of public attitudes to science.

    PubMed

    Smith, Benjamin K; Jensen, Eric A

    2016-02-01

    Since 2000, the UK government has funded surveys aimed at understanding the UK public's attitudes toward science, scientists, and science policy. Known as the Public Attitudes to Science series, these surveys and their predecessors have long been used in UK science communication policy, practice, and scholarship as a source of authoritative knowledge about science-related attitudes and behaviors. Given their importance and the significant public funding investment they represent, detailed academic scrutiny of the studies is needed. In this essay, we critically review the most recently published Public Attitudes to Science survey (2014), assessing the robustness of its methods and claims. The review casts doubt on the quality of key elements of the Public Attitudes to Science 2014 survey data and analysis while highlighting the importance of robust quantitative social research methodology. Our analysis comparing the main sample and booster sample for young people demonstrates that quota sampling cannot be assumed equivalent to probability-based sampling techniques. © The Author(s) 2016.

  3. Molecular rheology of branched polymers: decoding and exploring the role of architectural dispersity through a synergy of anionic synthesis, interaction chromatography, rheometry and modeling.

    PubMed

    van Ruymbeke, E; Lee, H; Chang, T; Nikopoulou, A; Hadjichristidis, N; Snijkers, F; Vlassopoulos, D

    2014-07-21

    An emerging challenge in polymer physics is the quantitative understanding of the influence of a macromolecular architecture (i.e., branching) on the rheological response of entangled complex polymers. Recent investigations of the rheology of well-defined architecturally complex polymers have determined the composition in the molecular structure and identified the role of side-products in the measured samples. The combination of different characterization techniques, experimental and/or theoretical, represents the current state-of-the-art. Here we review this interdisciplinary approach to molecular rheology of complex polymers, and show the importance of confronting these different tools for ensuring an accurate characterization of a given polymeric sample. We use statistical tools in order to relate the information available from the synthesis protocols of a sample and its experimental molar mass distribution (typically obtained from size exclusion chromatography), and hence obtain precise information about its structural composition, i.e. enhance the existing sensitivity limit. We critically discuss the use of linear rheology as a reliable quantitative characterization tool, along with the recently developed temperature gradient interaction chromatography. The latter, which has emerged as an indispensable characterization tool for branched architectures, offers unprecedented sensitivity in detecting the presence of different molecular structures in a sample. Combining these techniques is imperative in order to quantify the molecular composition of a polymer and its consequences on the macroscopic properties. We validate this approach by means of a new model asymmetric comb polymer which was synthesized anionically. It was thoroughly characterized and its rheology was carefully analyzed. The main result is that the rheological signal reveals fine molecular details, which must be taken into account to fully elucidate the viscoelastic response of entangled branched polymers. It is important to appreciate that, even optimal model systems, i.e., those synthesized with high-vacuum anionic methods, need thorough characterization via a combination of techniques. Besides helping to improve synthetic techniques, this methodology will be significant in fine-tuning mesoscopic tube-based models and addressing outstanding issues such as the quantitative description of the constraint release mechanism.

  4. Fourier transform infrared spectroscopy techniques for the analysis of drugs of abuse

    NASA Astrophysics Data System (ADS)

    Kalasinsky, Kathryn S.; Levine, Barry K.; Smith, Michael L.; Magluilo, Joseph J.; Schaefer, Teresa

    1994-01-01

    Cryogenic deposition techniques for Gas Chromatography/Fourier Transform Infrared (GC/FT-IR) can be successfully employed in urinalysis for drugs of abuse with detection limits comparable to those of the established Gas Chromatography/Mass Spectrometry (GC/MS) technique. The additional confidence of the data that infrared analysis can offer has been helpful in identifying ambiguous results, particularly, in the case of amphetamines where drugs of abuse can be confused with over-the-counter medications or naturally occurring amines. Hair analysis has been important in drug testing when adulteration of urine samples has been a question. Functional group mapping can further assist the analysis and track drug use versus time.

  5. Real-time shear velocity imaging using sonoelastographic techniques.

    PubMed

    Hoyt, Kenneth; Parker, Kevin J; Rubens, Deborah J

    2007-07-01

    In this paper, a novel sonoelastographic technique for estimating local shear velocities from propagating shear wave interference patterns (termed crawling waves) is introduced. A relationship between the local crawling wave spatial phase derivatives and local shear wave velocity is derived with phase derivatives estimated using an autocorrelation technique. Results from homogeneous phantoms demonstrate the ability of sonoelastographic shear velocity imaging to quantify the true underlying shear velocity distributions as verified using time-of-flight measurements. Heterogeneous phantom results reveal the capacity for lesion detection and shear velocity quantification as validated from mechanical measurements on phantom samples. Experimental results obtained from a prostate specimen illustrated feasibility for shear velocity imaging in tissue. More importantly, high-contrast visualization of focal carcinomas was demonstrated introducing the clinical potential of this novel sonoelastographic imaging technique.

  6. Disseminated histoplasmosis in a domestic cat imported from the USA to Austria

    PubMed Central

    Klang, Andrea; Loncaric, Igor; Spergser, Joachim; Eigelsreiter, Sabine; Weissenböck, Herbert

    2013-01-01

    We present a case of disseminated histoplasmosis in a domestic cat imported from the USA to Austria. Histopathological examination revealed a systemic mycosis with most severe involvement of the lungs suggestive of Histoplasma (H.) capsulatum-infection. Molecular confirmation was based on polymerase chain reaction (PCR) and sequence analysis of a fungal culture from liver samples. This is the first case of feline histoplasmosis proven by molecular diagnostic technique in Europe and reported in Austria, etc. PMID:24432230

  7. Sound velocity of tantalum under shock compression in the 18–142 GPa range

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xi, Feng, E-mail: xifeng@caep.cn; Jin, Ke; Cai, Lingcang, E-mail: cai-lingcang@aliyun.com

    2015-05-14

    Dynamic compression experiments of tantalum (Ta) within a shock pressure range from 18–142 GPa were conducted driven by explosive, a two-stage light gas gun, and a powder gun, respectively. The time-resolved Ta/LiF (lithium fluoride) interface velocity profiles were recorded with a displacement interferometer system for any reflector. Sound velocities of Ta were obtained from the peak state time duration measurements with the step-sample technique and the direct-reverse impact technique. The uncertainty of measured sound velocities were analyzed carefully, which suggests that the symmetrical impact method with step-samples is more accurate for sound velocity measurement, and the most important parameter in thismore » type experiment is the accurate sample/window particle velocity profile, especially the accurate peak state time duration. From these carefully analyzed sound velocity data, no evidence of a phase transition was found up to the shock melting pressure of Ta.« less

  8. [Molecular diagnostics of ALK-positive lung cancer].

    PubMed

    Tímár, József; Lotz, Gábor; Rásó, Erzsébet; Moldvay, Judit

    2017-09-20

    ALK translocation is the 3rd most frequent genetic aberration in lung adenocarcinoma, and several inhibitors are now clinically available in first and second line settings. Accordingly, molecular diagnostics of ALK-positive lung cancer is very important and can be done with the rational combination of several methods. All international recommendations suggest that, except for cytological samples, screening technology for ALK-positive tumors is immunohistochemistry using a validated test. It is highly recommended that in case of ALK protein positive samples gene translocation must be confirmed by fluorescent in situ hybridization (FISH). In case of cytological samples FISH technique must be used as ALK diagnostics. In equivocal cases the genetic alteration of ALK can be confirmed by alternative molecular techniques such as next generation sequencing or RNAbased PCR methods. Upon administration of ALK inhibitors, acquired resistance is frequent which is mostly due to ALK amplification and/or mutation. It is evident that the diagnostics of these secondary ALK gene alterations must be done from recurrent tumors or circulating nucleic acids.

  9. Analysis of estrogenic activity in environmental waters in Rio de Janeiro state (Brazil) using the yeast estrogen screen.

    PubMed

    Dias, Amanda Cristina Vieira; Gomes, Frederico Wegenast; Bila, Daniele Maia; Sant'Anna, Geraldo Lippel; Dezotti, Marcia

    2015-10-01

    The estrogenicity of waters collected from an important hydrological system in Brazil (Paraiba do Sul and Guandu Rivers) was assessed using the yeast estrogen screen (YES) assay. Sampling was performed in rivers and at the outlets of conventional water treatment plants (WTP). The removal of estrogenic activity by ozonation and chlorination after conventional water treatment (clarification and sand filtration) was investigated employing samples of the Guandu River spiked with estrogens and bisphenol A (BPA). The results revealed a preoccupying incidence of estrogenic activity at levels higher than 1ngL(-1) along some points of the rivers. Another matter of concern was the number of samples from WTPs presenting estrogenicity surpassing 1ngL(-1). The oxidation techniques (ozonation and chlorination) were effective for the removal of estrogenic activity and the combination of both techniques led to good results using less amounts of oxidants. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. The role of groundwater transport in aquatic mercury cycling

    USGS Publications Warehouse

    Krabbenhoft, David P.; Babiarz, Christopher L.

    1992-01-01

    Mercury, which is transported globally by atmospheric pathways to remote aquatic environments, is a ubiquitous contaminant at very low (nanograms Hg per liter) aqueous concentrations. Until recently, however, analytical and sampling techniques were not available for freshwater systems to quantify the actual levels of mercury concentrations without introducing significant contamination artifacts. Four different sampling strategies were used to evaluate ground water flow as a mercury source and transport mechanism within aquatic systems. The sampling strategies employ ultraclean techniques to determine mercury concentrations in groundwater and pore water near Pallette Lake, Wisconsin. Ambient groundwater concentrations are about 2–4 ng Hg L−1, whereas pore waters near the sediment/water interface average about 12 ng Hg L−1, emphasizing the importance of biogeochemical processes near the interface. Overall, the groundwater system removes about twice as much mercury (1.5 g yr−1) as it contributes (0.7 g yr−1) to Pallette Lake. About three fourths of the groundwater mercury load is recycled, thought to be derived from the water column.

  11. Reversible Cryopreservation of Living Cells Using an Electron Microscopy Cryo-Fixation Method.

    PubMed

    Huebinger, Jan; Han, Hong-Mei; Grabenbauer, Markus

    2016-01-01

    Rapid cooling of aqueous solutions is a useful approach for two important biological applications: (I) cryopreservation of cells and tissues for long-term storage, and (II) cryofixation for ultrastructural investigations by electron and cryo-electron microscopy. Usually, both approaches are very different in methodology. Here we show that a novel, fast and easy to use cryofixation technique called self-pressurized rapid freezing (SPRF) is-after some adaptations-also a useful and versatile technique for cryopreservation. Sealed metal tubes with high thermal diffusivity containing the samples are plunged into liquid cryogen. Internal pressure builds up reducing ice crystal formation and therefore supporting reversible cryopreservation through vitrification of cells. After rapid rewarming of pressurized samples, viability rates of > 90% can be reached, comparable to best-performing of the established rapid cooling devices tested. In addition, the small SPRF tubes allow for space-saving sample storage and the sealed containers prevent contamination from or into the cryogen during freezing, storage, or thawing.

  12. Preparation of samples for leaf architecture studies, a method for mounting cleared leaves1

    PubMed Central

    Vasco, Alejandra; Thadeo, Marcela; Conover, Margaret; Daly, Douglas C.

    2014-01-01

    • Premise of the study: Several recent waves of interest in leaf architecture have shown an expanding range of approaches and applications across a number of disciplines. Despite this increased interest, examination of existing archives of cleared and mounted leaves shows that current methods for mounting, in particular, yield unsatisfactory results and deterioration of samples over relatively short periods. Although techniques for clearing and staining leaves are numerous, published techniques for mounting leaves are scarce. • Methods and Results: Here we present a complete protocol and recommendations for clearing, staining, and imaging leaves, and, most importantly, a method to permanently mount cleared leaves. • Conclusions: The mounting protocol is faster than other methods, inexpensive, and straightforward; moreover, it yields clear and permanent samples that can easily be imaged, scanned, and stored. Specimens mounted with this method preserve well, with leaves that were mounted more than 35 years ago showing no signs of bubbling or discoloration. PMID:25225627

  13. To Screen Inactivation Mutation of Exon 1 of FSHR Gene in Polycystic Ovarian Syndrome: A South Indian Cohort Study

    NASA Astrophysics Data System (ADS)

    Sekar, Nishu; Yeole, Samiksha; Pradeep, Rashmi; Prabhu, Yogamaya D.; Renu, Kaviyarasi; Ramgir, Shalaka S.; Abilash, V. G.

    2017-11-01

    Polycystic ovary syndrome is an endocrine disorder. Irregular menstrual cycle, acne, facial hair and elevated androgen levels are the most common signs for PCOS. PCOS has an estimated prevalence of 4-12% among reproductive age women, thus making it a forerunner in female infertility. FSHR plays an important role in FSH signaling pathway making it an important gene for PCOS. In this study, we aim to focus on any association between the FSHR gene and PCOS. Our study was to evaluate any polymorphism of exon 1 of FSHR gene associated with PCOS.PCR-RFLP technique was performed on the PCOS samples. Hormonal changes were found in the patients. Exon 1 inactivation mutation of FSHR gene was not observed in the patient sample. A study of this association needs to be done using large sample size.

  14. Increased anterior default-mode network homogeneity in first-episode, drug-naive major depressive disorder: A replication study.

    PubMed

    Guo, Wenbin; Cui, Xilong; Liu, Feng; Chen, Jindong; Xie, Guangrong; Wu, Renrong; Zhang, Zhikun; Chen, Huafu; Zhao, Jingping

    2018-01-01

    Abnormal default-mode network (DMN) homogeneity has been involved in the neurophysiology of major depressive disorder (MDD) with inconsistent findings. The inconsistency may be due to clinical and methodological variability, and the reproducibility of the findings is limited. The present study aimed to examine alterations of the DMN homogeneity in two independent samples of patients with first-episode, drug-naive MDD. The samples included 59 patients with MDD and 31 comparison subjects from Sample 1 and 29 patients with MDD and 24 comparison subjects from Sample 2. Network homogeneity (NH) was computed with an overlapping technique, which was employed to define brain regions with abnormal NH common to the MDD samples. Compared with comparison subjects, patients with MDD exhibited increased NH in an overlapped brain region of the left superior medial prefrontal cortex (MPFC). No correlations were found between abnormal NH and HAMD total/subscale scores in the patients of each sample and in the combined patients from both samples. This study is the first to examine alterations of DMN homogeneity in first-episode, drug-naive patients with MDD in two independent samples by using an overlapping technique. Patients with MDD exhibit increased NH in an overlapped region in the anterior DMN. The present study thus highlights the importance of the DMN in the neurophysiology of MDD. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Active Search on Carcasses versus Pitfall Traps: a Comparison of Sampling Methods.

    PubMed

    Zanetti, N I; Camina, R; Visciarelli, E C; Centeno, N D

    2016-04-01

    The study of insect succession in cadavers and the classification of arthropods have mostly been done by placing a carcass in a cage, protected from vertebrate scavengers, which is then visited periodically. An alternative is to use specific traps. Few studies on carrion ecology and forensic entomology involving the carcasses of large vertebrates have employed pitfall traps. The aims of this study were to compare both sampling methods (active search on a carcass and pitfall trapping) for each coleopteran family, and to establish whether there is a discrepancy (underestimation and/or overestimation) in the presence of each family by either method. A great discrepancy was found for almost all families with some of them being more abundant in samples obtained through active search on carcasses and others in samples from traps, whereas two families did not show any bias towards a given sampling method. The fact that families may be underestimated or overestimated by the type of sampling technique highlights the importance of combining both methods, active search on carcasses and pitfall traps, in order to obtain more complete information on decomposition, carrion habitat and cadaveric families or species. Furthermore, a hypothesis advanced on the reasons for the underestimation by either sampling method showing biases towards certain families. Information about the sampling techniques indicating which would be more appropriate to detect or find a particular family is provided.

  16. Efficiency of analytical and sampling-based uncertainty propagation in intensity-modulated proton therapy

    NASA Astrophysics Data System (ADS)

    Wahl, N.; Hennig, P.; Wieser, H. P.; Bangert, M.

    2017-07-01

    The sensitivity of intensity-modulated proton therapy (IMPT) treatment plans to uncertainties can be quantified and mitigated with robust/min-max and stochastic/probabilistic treatment analysis and optimization techniques. Those methods usually rely on sparse random, importance, or worst-case sampling. Inevitably, this imposes a trade-off between computational speed and accuracy of the uncertainty propagation. Here, we investigate analytical probabilistic modeling (APM) as an alternative for uncertainty propagation and minimization in IMPT that does not rely on scenario sampling. APM propagates probability distributions over range and setup uncertainties via a Gaussian pencil-beam approximation into moments of the probability distributions over the resulting dose in closed form. It supports arbitrary correlation models and allows for efficient incorporation of fractionation effects regarding random and systematic errors. We evaluate the trade-off between run-time and accuracy of APM uncertainty computations on three patient datasets. Results are compared against reference computations facilitating importance and random sampling. Two approximation techniques to accelerate uncertainty propagation and minimization based on probabilistic treatment plan optimization are presented. Runtimes are measured on CPU and GPU platforms, dosimetric accuracy is quantified in comparison to a sampling-based benchmark (5000 random samples). APM accurately propagates range and setup uncertainties into dose uncertainties at competitive run-times (GPU ≤slant {5} min). The resulting standard deviation (expectation value) of dose show average global γ{3% / {3}~mm} pass rates between 94.2% and 99.9% (98.4% and 100.0%). All investigated importance sampling strategies provided less accuracy at higher run-times considering only a single fraction. Considering fractionation, APM uncertainty propagation and treatment plan optimization was proven to be possible at constant time complexity, while run-times of sampling-based computations are linear in the number of fractions. Using sum sampling within APM, uncertainty propagation can only be accelerated at the cost of reduced accuracy in variance calculations. For probabilistic plan optimization, we were able to approximate the necessary pre-computations within seconds, yielding treatment plans of similar quality as gained from exact uncertainty propagation. APM is suited to enhance the trade-off between speed and accuracy in uncertainty propagation and probabilistic treatment plan optimization, especially in the context of fractionation. This brings fully-fledged APM computations within reach of clinical application.

  17. Efficiency of analytical and sampling-based uncertainty propagation in intensity-modulated proton therapy.

    PubMed

    Wahl, N; Hennig, P; Wieser, H P; Bangert, M

    2017-06-26

    The sensitivity of intensity-modulated proton therapy (IMPT) treatment plans to uncertainties can be quantified and mitigated with robust/min-max and stochastic/probabilistic treatment analysis and optimization techniques. Those methods usually rely on sparse random, importance, or worst-case sampling. Inevitably, this imposes a trade-off between computational speed and accuracy of the uncertainty propagation. Here, we investigate analytical probabilistic modeling (APM) as an alternative for uncertainty propagation and minimization in IMPT that does not rely on scenario sampling. APM propagates probability distributions over range and setup uncertainties via a Gaussian pencil-beam approximation into moments of the probability distributions over the resulting dose in closed form. It supports arbitrary correlation models and allows for efficient incorporation of fractionation effects regarding random and systematic errors. We evaluate the trade-off between run-time and accuracy of APM uncertainty computations on three patient datasets. Results are compared against reference computations facilitating importance and random sampling. Two approximation techniques to accelerate uncertainty propagation and minimization based on probabilistic treatment plan optimization are presented. Runtimes are measured on CPU and GPU platforms, dosimetric accuracy is quantified in comparison to a sampling-based benchmark (5000 random samples). APM accurately propagates range and setup uncertainties into dose uncertainties at competitive run-times (GPU [Formula: see text] min). The resulting standard deviation (expectation value) of dose show average global [Formula: see text] pass rates between 94.2% and 99.9% (98.4% and 100.0%). All investigated importance sampling strategies provided less accuracy at higher run-times considering only a single fraction. Considering fractionation, APM uncertainty propagation and treatment plan optimization was proven to be possible at constant time complexity, while run-times of sampling-based computations are linear in the number of fractions. Using sum sampling within APM, uncertainty propagation can only be accelerated at the cost of reduced accuracy in variance calculations. For probabilistic plan optimization, we were able to approximate the necessary pre-computations within seconds, yielding treatment plans of similar quality as gained from exact uncertainty propagation. APM is suited to enhance the trade-off between speed and accuracy in uncertainty propagation and probabilistic treatment plan optimization, especially in the context of fractionation. This brings fully-fledged APM computations within reach of clinical application.

  18. Impact of changing from staining to culture techniques on detection rates of Campylobacter spp. in routine stool samples in Chile.

    PubMed

    Porte, Lorena; Varela, Carmen; Haecker, Thomas; Morales, Sara; Weitzel, Thomas

    2016-05-13

    Campylobacter is a leading cause of bacterial gastroenteritis, but sensitive diagnostic methods such as culture are expensive and often not available in resource limited settings. Therefore, direct staining techniques have been developed as a practical and economical alternative. We analyzed the impact of replacing Campylobacter staining with culture for routine stool examinations in a private hospital in Chile. From January to April 2014, a total of 750 consecutive stool samples were examined in parallel by Hucker stain and Campylobacter culture. Isolation rates of Campylobacter were determined and the performance of staining was evaluated against culture as the gold standard. Besides, isolation rates of Campylobacter and other enteric pathogens were compared to those of past years. Campylobacter was isolated by culture in 46 of 750 (6.1 %) stool samples. Direct staining only identified three samples as Campylobacter positive and reached sensitivity and specificity values of 6.5 and 100 %, respectively. In comparison to staining-based detection rates of previous years, we observed a significant increase of Campylobacter cases in our patients. Direct staining technique for Campylobacter had a very low sensitivity compared to culture. Staining methods might lead to a high rate of false negative results and an underestimation of the importance of campylobacteriosis. With the inclusion of Campylobacter culture, this pathogen became a leading cause of intestinal infection in our patient population.

  19. Measurements of Gas-Wall Partitioning of Oxidized Species in Environmental Smog Chambers and Teflon Sampling Lines

    NASA Astrophysics Data System (ADS)

    Krechmer, J.; Pagonis, D.; Ziemann, P. J.; Jimenez, J. L.

    2015-12-01

    Environmental "smog" chambers have played an integral role in atmospheric aerosol research for decades. Recently, many works have demonstrated that the loss of gas-phase material to fluorinated ethylene propylene (FEP) chamber walls can have significant effects on secondary organic aerosol (SOA) yield results. The effects of gas-wall partitioning on highly oxidized species is still controversial, however. In this work we performed a series of experiments examining the losses of oxidized gas-phase compounds that were generated in-situ­ in an environmental chamber. The loss of species to the walls was measured using three chemical ionization mass spectrometry techniques: proton-transfer-reaction (PTR), nitrate (NO3-) ion, and iodide (I-). Many oxidized species have wall loss timescales ranging between 15 to 45 minutes and scale according to the molecule's estimated saturation concentration c* and functional groups. By comparing results of the different techniques, and in particular by the use of the "wall-less" NO3- source, we find that measuring species with high chamber wall-loss rates is complicated by the use of a standard ion-molecule reaction (IMR) region, as well as long Teflon sampling lines, which can be important sinks for gas-phase species. This effect is observed even for semi-volatile species and could have significant effects on ambient sampling techniques that make highly time-resolved measurements using long sampling lines, such as eddy covariance measurements.

  20. A PLL-based resampling technique for vibration analysis in variable-speed wind turbines with PMSG: A bearing fault case

    NASA Astrophysics Data System (ADS)

    Pezzani, Carlos M.; Bossio, José M.; Castellino, Ariel M.; Bossio, Guillermo R.; De Angelo, Cristian H.

    2017-02-01

    Condition monitoring in permanent magnet synchronous machines has gained interest due to the increasing use in applications such as electric traction and power generation. Particularly in wind power generation, non-invasive condition monitoring techniques are of great importance. Usually, in such applications the access to the generator is complex and costly, while unexpected breakdowns results in high repair costs. This paper presents a technique which allows using vibration analysis for bearing fault detection in permanent magnet synchronous generators used in wind turbines. Given that in wind power applications the generator rotational speed may vary during normal operation, it is necessary to use special sampling techniques to apply spectral analysis of mechanical vibrations. In this work, a resampling technique based on order tracking without measuring the rotor position is proposed. To synchronize sampling with rotor position, an estimation of the rotor position obtained from the angle of the voltage vector is proposed. This angle is obtained from a phase-locked loop synchronized with the generator voltages. The proposed strategy is validated by laboratory experimental results obtained from a permanent magnet synchronous generator. Results with single point defects in the outer race of a bearing under variable speed and load conditions are presented.

  1. Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating.

    PubMed

    Bacchi, Atais; Regalin, Alexandre; Bhering, Claudia Lopes Brilhante; Alessandretti, Rodrigo; Spazzin, Aloisio Oro

    2015-10-01

    The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading. Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A - torque with 32 Ncm (control); B - torque with 32 Ncm holding the torque meter for 20 seconds; C - torque with 32 Ncm and retorque after 10 minutes; D - torque (32 Ncm) holding the torque meter for 20 seconds and retorque after 10 minutes as initially. Samples were divided into subgroups according to the screw used: conventional titanium screw or diamond like carbon-coated (DLC) screw. Metallic crowns were fabricated for each abutment. Samples were submitted to cyclic loading at 10(6) cycles and 130 N of force. Data were analyzed by two-way ANOVA and Tukey's test (5%). The tightening technique did not show significant influence on the loosening torque of screws (P=.509). Conventional titanium screws showed significant higher loosening torque values than DLC (P=.000). The use of conventional titanium screw is more important than the tightening techniques employed in this study to provide long-term stability to Universal Abutment screws.

  2. Enhanced algorithms for stochastic programming

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krishna, Alamuru S.

    1993-09-01

    In this dissertation, we present some of the recent advances made in solving two-stage stochastic linear programming problems of large size and complexity. Decomposition and sampling are two fundamental components of techniques to solve stochastic optimization problems. We describe improvements to the current techniques in both these areas. We studied different ways of using importance sampling techniques in the context of Stochastic programming, by varying the choice of approximation functions used in this method. We have concluded that approximating the recourse function by a computationally inexpensive piecewise-linear function is highly efficient. This reduced the problem from finding the mean ofmore » a computationally expensive functions to finding that of a computationally inexpensive function. Then we implemented various variance reduction techniques to estimate the mean of a piecewise-linear function. This method achieved similar variance reductions in orders of magnitude less time than, when we directly applied variance-reduction techniques directly on the given problem. In solving a stochastic linear program, the expected value problem is usually solved before a stochastic solution and also to speed-up the algorithm by making use of the information obtained from the solution of the expected value problem. We have devised a new decomposition scheme to improve the convergence of this algorithm.« less

  3. The great importance of normalization of LC-MS data for highly-accurate non-targeted metabolomics.

    PubMed

    Mizuno, Hajime; Ueda, Kazuki; Kobayashi, Yuta; Tsuyama, Naohiro; Todoroki, Kenichiro; Min, Jun Zhe; Toyo'oka, Toshimasa

    2017-01-01

    The non-targeted metabolomics analysis of biological samples is very important to understand biological functions and diseases. LC combined with electrospray ionization-based MS has been a powerful tool and widely used for metabolomic analyses. However, the ionization efficiency of electrospray ionization fluctuates for various unexpected reasons such as matrix effects and intraday variations of the instrument performances. To remove these fluctuations, normalization methods have been developed. Such techniques include increasing the sensitivity, separating co-eluting components and normalizing the ionization efficiencies. Normalization techniques allow simultaneously correcting of the ionization efficiencies of the detected metabolite peaks and achieving quantitative non-targeted metabolomics. In this review paper, we focused on these normalization methods for non-targeted metabolomics by LC-MS. Copyright © 2016 John Wiley & Sons, Ltd.

  4. Anisotropy in thermal conductivity of graphite flakes–SiC{sub p}/matrix composites: Implications in heat sinking design for thermal management applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Molina, J.M., E-mail: jmmj@ua.es; Departamento de Física Aplicada, Universidad de Alicante, Ap. 99, E-03080 Alicante; Departamento de Química Inorgánica, Universidad de Alicante, Ap. 99, | E-03080 Alicante

    2015-11-15

    Within the frame of heat dissipation for electronics, a very interesting family of anisotropic composite materials, fabricated by liquid infiltration of a matrix into preforms of oriented graphite flakes and SiC particles, has been recently proposed. Aiming to investigate the implications of the inherent anisotropy of these composites on their thermal conductivity, and hence on their potential applications, materials with matrices of Al–12 wt.% Si alloy and epoxy polymer have been fabricated. Samples have been cut at a variable angle with respect to the flakes plane and thermal conductivity has been measured by means of two standard techniques, namely, steadymore » state technique and laser flash method. Experimental results are presented and discussed in terms of current models, from which important technological implications for heat sinking design can be derived. - Highlights: • Anisotropy in thermal conductivity of graphite flakes-based composites is evaluated. • Samples are cut in a direction forming a variable angle with the oriented flakes. • For angles 0° and 90°, thermal conductivity does not depend on sample geometry. • For intermediate angles, thermal conductivity strongly depends on sample geometry. • “Thin” samples must be thicker than 600 μm, “thick” samples must be encapsulated.« less

  5. Lunar carbon chemistry - Relations to and implications for terrestrial organic geochemistry.

    NASA Technical Reports Server (NTRS)

    Eglinton, G.; Maxwell, J. R.; Pillinger, C. T.

    1972-01-01

    Survey of the various ways in which studies of lunar carbon chemistry have beneficially affected terrestrial organic geochemistry. A lunar organic gas-analysis operating system is cited as the most important instrumental development in relation to terrestrial organic geochemistry. Improved methods of analysis and handling of organic samples are cited as another benefit derived from studies of lunar carbon chemistry. The problem of controlling contamination and minimizing organic vapors is considered, as well as the possibility of analyzing terrestrial samples by the techniques developed for lunar samples. A need for new methods of analyzing carbonaceous material which is insoluble in organic solvents is indicated.

  6. Quantitative Analysis of Defects in Silicon. [to predict energy conversion efficiency of silicon samples for solar cells

    NASA Technical Reports Server (NTRS)

    Natesh, R.; Smith, J. M.; Qidwai, H. A.; Bruce, T.

    1979-01-01

    The evaluation and prediction of the conversion efficiency for a variety of silicon samples with differences in structural defects, such as grain boundaries, twin boundaries, precipitate particles, dislocations, etc. are discussed. Quantitative characterization of these structural defects, which were revealed by etching the surface of silicon samples, is performed by using an image analyzer. Due to different crystal growth and fabrication techniques the various types of silicon contain a variety of trace impurity elements and structural defects. The two most important criteria in evaluating the various silicon types for solar cell applications are cost and conversion efficiency.

  7. Comparative study of some commercial samples of naga bhasma.

    PubMed

    Wadekar, Mrudula; Gogte, Viswas; Khandagale, Prasad; Prabhune, Asmita

    2004-04-01

    Naga bhasma is one of those reputed ayurvedic bhasmas which are claimed to possess some extraordinary medical properties. However, identification of a genuine sample of naga bhasma is a challenging problem. Because at present naga bhasma is manufactured by different ayurvedic pharmacies, by following different methods, these products are not standardised either from chemical and structural point of view. Therefore, comparative study of these samples using modern analytical techniques is important and necessary to understand their current status. In this communication, such study of naga bhasma from chemical and structural point of view is reported by using XRD, IR and UV spectroscopy and thermogravimetry.

  8. The Lunar Sample Compendium

    NASA Technical Reports Server (NTRS)

    Meyer, Charles

    2009-01-01

    The Lunar Sample Compendium is a succinct summary of the data obtained from 40 years of study of Apollo and Luna samples of the Moon. Basic petrographic, chemical and age information is compiled, sample-by-sample, in the form of an advanced catalog in order to provide a basic description of each sample. The LSC can be found online using Google. The initial allocation of lunar samples was done sparingly, because it was realized that scientific techniques would improve over the years and new questions would be formulated. The LSC is important because it enables scientists to select samples within the context of the work that has already been done and facilitates better review of proposed allocations. It also provides back up material for public displays, captures information found only in abstracts, grey literature and curatorial databases and serves as a ready access to the now-vast scientific literature.

  9. Invited review article: Photopyroelectric calorimeter for the simultaneous thermal, optical, and structural characterization of samples over phase transitions.

    PubMed

    Zammit, U; Marinelli, M; Mercuri, F; Paoloni, S; Scudieri, F

    2011-12-01

    The study of thermophysical properties is of great importance in several scientific fields. Among them, the heat capacity, for example, is related to the microscopic structure of condensed matter and plays an important role in monitoring the changes in the energy content of a system. Calorimetric techniques are thus of fundamental importance for characterizing physical systems, particularly in the vicinity of phase transitions where energy fluctuations can play an important role. In this work, the ability of the Photopyroelctric calorimetry to study the versus temperature behaviour of the specific heat and of the other thermal parameters in the vicinity of phase transitions is outlined. The working principle, the theoretical basis, the experimental configurations, and the advantages of this technique, with respect to the more conventional ones, have been described and discussed in detail. The integrations in the calorimetric setup giving the possibility to perform, simultaneously with the calorimetric studies, complementary kind of characterizations of optical, structural, and electrical properties are also described. A review of the results obtained with this technique, in all its possible configurations, for the high temperature resolution studies of the thermal parameters over several kinds of phase transitions occurring in different systems is presented and discussed.

  10. Identifying the Threshold of Dominant Controls on Fire Spread in a Boreal Forest Landscape of Northeast China

    PubMed Central

    Liu, Zhihua; Yang, Jian; He, Hong S.

    2013-01-01

    The relative importance of fuel, topography, and weather on fire spread varies at different spatial scales, but how the relative importance of these controls respond to changing spatial scales is poorly understood. We designed a “moving window” resampling technique that allowed us to quantify the relative importance of controls on fire spread at continuous spatial scales using boosted regression trees methods. This quantification allowed us to identify the threshold value for fire size at which the dominant control switches from fuel at small sizes to weather at large sizes. Topography had a fluctuating effect on fire spread across the spatial scales, explaining 20–30% of relative importance. With increasing fire size, the dominant control switched from bottom-up controls (fuel and topography) to top-down controls (weather). Our analysis suggested that there is a threshold for fire size, above which fires are driven primarily by weather and more likely lead to larger fire size. We suggest that this threshold, which may be ecosystem-specific, can be identified using our “moving window” resampling technique. Although the threshold derived from this analytical method may rely heavily on the sampling technique, our study introduced an easily implemented approach to identify scale thresholds in wildfire regimes. PMID:23383247

  11. Estimating forest canopy bulk density using six indirect methods

    Treesearch

    Robert E. Keane; Elizabeth D. Reinhardt; Joe Scott; Kathy Gray; James Reardon

    2005-01-01

    Canopy bulk density (CBD) is an important crown characteristic needed to predict crown fire spread, yet it is difficult to measure in the field. Presented here is a comprehensive research effort to evaluate six indirect sampling techniques for estimating CBD. As reference data, detailed crown fuel biomass measurements were taken on each tree within fixed-area plots...

  12. New Horizon of Spiritual Well-Being and Hope among Cancer Patients: A Psychological Aspect

    ERIC Educational Resources Information Center

    Liaquat, Sidra; Sultan, Sarwat; Hussain, Irshad

    2013-01-01

    The purpose of this study was to address the importance of spiritual well-being and hope among cancer patients diagnosed with its different stages. Through stratified sampling techniques, 120 cancer patients from four stages evenly divided into male and female participated in this study. Spiritual Well-being Scale (Paloutzian & Ellison, 1982)…

  13. Using Sibling Samples To Assess the Effect of Childhood Family Income on Completed Schooling. JCPR Working Paper.

    ERIC Educational Resources Information Center

    Levy, Dan; Duncan, Greg J.

    This study assessed the impact of family childhood income on completed years of schooling using fixed effects techniques to eliminate biases associated with omission of unmeasured family characteristics. It also examined the importance of timing of family income, estimating models that related years of completed schooling to average levels of…

  14. [Improving self-control in substance dependent persons and pathological gamblers--a pilot study].

    PubMed

    Nespor, K; Csémy, L

    2006-01-01

    Impaired self-control is an important symptom of addictive diseases. The average number of factors improving self-control among 117 men dependent on alcohol, other substances and pathological gamblers was 5.55 (SD=3.5). We classified strategies how to improve self-control into following groups (their ordering reflects the frequency of their use in our sample): 1. The help of others (professional treatment, self-help groups, and family), 2. Distraction and similar techniques, 3. The use of motivation, 4. Life-style changes including appropriate rest, 5. Physical activity, sports, physical work, 6. The use of environments, 7. Mastering of social and other relevant skills, 8. Relaxation based approaches, 9. Techniques working with improved self-awareness, 10. Pharmacotherapy, 11. Acknowledgement of an addictive disease and abstinence, 12. Disrupting risky behavioral patterns. To improve of self-control in addictive diseases simple techniques are appropriate because of temporarily impaired cognitive functions during craving. Frequent repetition are also important.

  15. Scrambled eggs: A highly sensitive molecular diagnostic workflow for Fasciola species specific detection from faecal samples.

    PubMed

    Calvani, Nichola Eliza Davies; Windsor, Peter Andrew; Bush, Russell David; Šlapeta, Jan

    2017-09-01

    Fasciolosis, due to Fasciola hepatica and Fasciola gigantica, is a re-emerging zoonotic parasitic disease of worldwide importance. Human and animal infections are commonly diagnosed by the traditional sedimentation and faecal egg-counting technique. However, this technique is time-consuming and prone to sensitivity errors when a large number of samples must be processed or if the operator lacks sufficient experience. Additionally, diagnosis can only be made once the 12-week pre-patent period has passed. Recently, a commercially available coprological antigen ELISA has enabled detection of F. hepatica prior to the completion of the pre-patent period, providing earlier diagnosis and increased throughput, although species differentiation is not possible in areas of parasite sympatry. Real-time PCR offers the combined benefits of highly sensitive species differentiation for medium to large sample sizes. However, no molecular diagnostic workflow currently exists for the identification of Fasciola spp. in faecal samples. A new molecular diagnostic workflow for the highly-sensitive detection and quantification of Fasciola spp. in faecal samples was developed. The technique involves sedimenting and pelleting the samples prior to DNA isolation in order to concentrate the eggs, followed by disruption by bead-beating in a benchtop homogeniser to ensure access to DNA. Although both the new molecular workflow and the traditional sedimentation technique were sensitive and specific, the new molecular workflow enabled faster sample throughput in medium to large epidemiological studies, and provided the additional benefit of speciation. Further, good correlation (R2 = 0.74-0.76) was observed between the real-time PCR values and the faecal egg count (FEC) using the new molecular workflow for all herds and sampling periods. Finally, no effect of storage in 70% ethanol was detected on sedimentation and DNA isolation outcomes; enabling transport of samples from endemic to non-endemic countries without the requirement of a complete cold chain. The commercially-available ELISA displayed poorer sensitivity, even after adjustment of the positive threshold (65-88%), compared to the sensitivity (91-100%) of the new molecular diagnostic workflow. Species-specific assays for sensitive detection of Fasciola spp. enable ante-mortem diagnosis in both human and animal settings. This includes Southeast Asia where there are potentially many undocumented human cases and where post-mortem examination of production animals can be difficult. The new molecular workflow provides a sensitive and quantitative diagnostic approach for the rapid testing of medium to large sample sizes, potentially superseding the traditional sedimentation and FEC technique and enabling surveillance programs in locations where animal and human health funding is limited.

  16. Use of a (137)Cs re-sampling technique to investigate temporal changes in soil erosion and sediment mobilisation for a small forested catchment in southern Italy.

    PubMed

    Porto, Paolo; Walling, Des E; Alewell, Christine; Callegari, Giovanni; Mabit, Lionel; Mallimo, Nicola; Meusburger, Katrin; Zehringer, Markus

    2014-12-01

    Soil erosion and both its on-site and off-site impacts are increasingly seen as a serious environmental problem across the world. The need for an improved evidence base on soil loss and soil redistribution rates has directed attention to the use of fallout radionuclides, and particularly (137)Cs, for documenting soil redistribution rates. This approach possesses important advantages over more traditional means of documenting soil erosion and soil redistribution. However, one key limitation of the approach is the time-averaged or lumped nature of the estimated erosion rates. In nearly all cases, these will relate to the period extending from the main period of bomb fallout to the time of sampling. Increasing concern for the impact of global change, particularly that related to changing land use and climate change, has frequently directed attention to the need to document changes in soil redistribution rates within this period. Re-sampling techniques, which should be distinguished from repeat-sampling techniques, have the potential to meet this requirement. As an example, the use of a re-sampling technique to derive estimates of the mean annual net soil loss from a small (1.38 ha) forested catchment in southern Italy is reported. The catchment was originally sampled in 1998 and samples were collected from points very close to the original sampling points again in 2013. This made it possible to compare the estimate of mean annual erosion for the period 1954-1998 with that for the period 1999-2013. The availability of measurements of sediment yield from the catchment for parts of the overall period made it possible to compare the results provided by the (137)Cs re-sampling study with the estimates of sediment yield for the same periods. In order to compare the estimates of soil loss and sediment yield for the two different periods, it was necessary to establish the uncertainty associated with the individual estimates. In the absence of a generally accepted procedure for such calculations, key factors influencing the uncertainty of the estimates were identified and a procedure developed. The results of the study demonstrated that there had been no significant change in mean annual soil loss in recent years and this was consistent with the information provided by the estimates of sediment yield from the catchment for the same periods. The study demonstrates the potential for using a re-sampling technique to document recent changes in soil redistribution rates. Copyright © 2014. Published by Elsevier Ltd.

  17. Decalin-assisted light emitting porous Si formation and its optical, surface and morphological properties

    NASA Astrophysics Data System (ADS)

    Karatutlu, Ali; Istengir, Sumeyra; Cosgun, Sedat; Seker, Isa; Unal, Bayram

    2017-11-01

    In this research paper, light emitting porous silicon (Lep-Si) samples were fabricated by a surfactant-mediated chemical stain etching solution in order to form homogenous luminescent nanostructures at room temperature. As an industrially important solvent, decalin (decahydronaphtalene) was used as a surfactant in the HF/HNO3 solutions in order to control the etching process. Morphological, surface and optical properties of the Lep-Si samples were examined using atomic force microscopy, X-ray photoelectron spectroscopy, photoluminescence (PL) spectroscopy, and laser scanning confocal microscopy (LSCM) techniques. These characterization techniques were correlated with the various etching times including depth dependent luminescence profiles for the first time. We report the optimum conditions for production of the most efficient Lep-Si using decalin (decahydronaphtalene) and possible structural origins of light emission using the depth dependent luminescence measurements.

  18. Wedge sampling for computing clustering coefficients and triangle counts on large graphs

    DOE PAGES

    Seshadhri, C.; Pinar, Ali; Kolda, Tamara G.

    2014-05-08

    Graphs are used to model interactions in a variety of contexts, and there is a growing need to quickly assess the structure of such graphs. Some of the most useful graph metrics are based on triangles, such as those measuring social cohesion. Despite the importance of these triadic measures, algorithms to compute them can be extremely expensive. We discuss the method of wedge sampling. This versatile technique allows for the fast and accurate approximation of various types of clustering coefficients and triangle counts. Furthermore, these techniques are extensible to counting directed triangles in digraphs. Our methods come with provable andmore » practical time-approximation tradeoffs for all computations. We provide extensive results that show our methods are orders of magnitude faster than the state of the art, while providing nearly the accuracy of full enumeration.« less

  19. Combining Capillary Electrophoresis with Mass Spectrometry for Applications in Proteomics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simpson, David C.; Smith, Richard D.

    2005-04-01

    Throughout the field of global proteomics, ranging from simple organism studies to human medical applications, the high sample complexity creates demands for improved separations and analysis techniques. Furthermore, with increased organism complexity, the correlation between proteome and genome becomes less certain due to extensive mRNA processing prior to translation. In this way, the same DNA sequence can potentially code for regions in a number of distinct proteins; quantitative differences in expression (or abundance) between these often-related species are of significant interest. Well-established proteomics techniques, which use genomic information to identify peptides that originate from protease digestion, often cannot easily distinguishmore » between such gene products; intact protein-level analyses are required to complete the picture, particularly for identifying post-translational modifications. While chromatographic techniques are currently better suited to peptide analysis, capillary electrophoresis (CE) in combination with mass spectrometry (MS) may become important for intact protein analysis. This review focuses on CE/MS instrumentation and techniques showing promise for such applications, highlighting those with greatest potential. Reference will also be made to developments relevant to peptide-level analyses for use in time- or sample-limited situations.« less

  20. Continued Development of In Situ Geochronology for Planetary Missions Using KArLE (Potassium-Argon-Laser Experiment)

    NASA Technical Reports Server (NTRS)

    Devismes, Damien; Cohen, Barbara

    2016-01-01

    Since these techniques are very new and as they have never been used or this purpose. they will need to be replicated by several independent studies. These techniques may be very important if the optical imaging encounters difficulties, for example, if a sample is made of very dark or monochromatic material and in the case of very deep pits (>500 microns) Based on the preliminary results, the LIBS continuum technique is more appropriate to the large pits produced by long ablations The relationship may work best homogeneous samples, but the continuum is collected with every LIBS analysis so does not require any addition to the experimental suite of techniques. The integration of a QCMB in the ablation chamber may be a very interesting solution to determine the ablated mass. Even if it only measures a fraction of the total mass, its sensitivity should be able to weigh hundreds of nanograms accumulated on the crystal during ablation and relate it to the actual ablated mass. In the future. these options may help in situ K-Ar dating to give the age of the rock with the best accuracy and precision.

  1. Heterogeneity and frequency of BRAF mutations in primary melanoma: Comparison between molecular methods and immunohistochemistry

    PubMed Central

    Bruno, William; Martinuzzi, Claudia; Andreotti, Virginia; Pastorino, Lorenza; Spagnolo, Francesco; Dalmasso, Bruna; Cabiddu, Francesco; Gualco, Marina; Ballestrero, Alberto; Bianchi-Scarrà, Giovanna; Queirolo, Paola

    2017-01-01

    Finding the best technique to identify BRAF mutations with a high sensitivity and specificity is mandatory for accurate patient selection for target therapy. BRAF mutation frequency ranges from 40 to 60% depending on melanoma clinical characteristics and detection technique used. Intertumoral heterogeneity could lead to misinterpretation of BRAF mutational status; this is especially important if testing is performed on primary specimens, when metastatic lesions are unavailable. Aim of this study was to identify the best combination of methods for detecting BRAF mutations (among peptide nucleic acid – PNA-clamping real-time PCR, immunohistochemistry and capillary sequencing) and investigate BRAF mutation heterogeneity in a series of 100 primary melanomas and a subset of 25 matched metastatic samples. Overall, we obtained a BRAF mutation frequency of 62%, based on the combination of at least two techniques. Concordance between mutation status in primary and metastatic tumor was good but not complete (67%), when agreement of at least two techniques were considered. Next generation sequencing was used to quantify the threshold of detected mutant alleles in discordant samples. Combining different methods excludes that the observed heterogeneity is technique-based. We propose an algorithm for BRAF mutation testing based on agreement between immunohistochemistry and PNA; a third molecular method could be added in case of discordance of the results. Testing the primary tumor when the metastatic sample is unavailable is a good option if at least two methods of detection are used, however the presence of intertumoral heterogeneity or the occurrence of additional primaries should be carefully considered. PMID:28039443

  2. Chromatic changes to artificial irises produced using different techniques

    NASA Astrophysics Data System (ADS)

    Bannwart, Lisiane Cristina; Goiato, Marcelo Coelho; dos Santos, Daniela Micheline; Moreno, Amália; Pesqueira, Aldiéris Alves; Haddad, Marcela Filié; Andreotti, Agda Marobo; de Medeiros, Rodrigo Antonio

    2013-05-01

    Ocular prostheses are important determinants of their users' aesthetic recovery and self-esteem. Because of use, ocular prostheses longevity is strongly affected by instability of the iris color due to polymerization. The goal of this study is to examine how the color of the artificial iris button is affected by different techniques of artificial wear and by the application of varnish following polymerization of the colorless acrylic resin that covers the colored paint. We produce 60 samples (n=10) according to the wear technique applied: conventional technique without varnish (PE); conventional technique with varnish (PEV); technique involving a prefabricated cap without varnish (CA); technique involving a prefabricated cap with varnish (CAV); technique involving inverted painting without varnish (PI); and technique involving inverted painting with varnish (PIV). Color readings using a spectrophotometer are taken before and after polymerization. We submitted the data obtained to analyses of variance and Tukey's test (P<0.05). The color test shows significant changes after polymerization in all groups. The PE and PI techniques have clinically acceptable values of ΔE, independent of whether we apply varnish to protect the paint. The PI technique produces the least color change, whereas the PE and CA techniques significantly improve color stability.

  3. Au nanostructure arrays for plasmonic applications: annealed island films versus nanoimprint lithography

    NASA Astrophysics Data System (ADS)

    Lopatynskyi, Andrii M.; Lytvyn, Vitalii K.; Nazarenko, Volodymyr I.; Guo, L. Jay; Lucas, Brandon D.; Chegel, Volodymyr I.

    2015-03-01

    This paper attempts to compare the main features of random and highly ordered gold nanostructure arrays (NSA) prepared by thermally annealed island film and nanoimprint lithography (NIL) techniques, respectively. Each substrate possesses different morphology in terms of plasmonic enhancement. Both methods allow such important features as spectral tuning of plasmon resonance position depending on size and shape of nanostructures; however, the time and cost is quite different. The respective comparison was performed experimentally and theoretically for a number of samples with different geometrical parameters. Spectral characteristics of fabricated NSA exhibited an expressed plasmon peak in the range from 576 to 809 nm for thermally annealed samples and from 606 to 783 nm for samples prepared by NIL. Modelling of the optical response for nanostructures with typical shapes associated with these techniques (parallelepiped for NIL and semi-ellipsoid for annealed island films) was performed using finite-difference time-domain calculations. Mathematical simulations have indicated the dependence of electric field enhancement on the shape and size of the nanoparticles. As an important point, the distribution of electric field at so-called `hot spots' was considered. Parallelepiped-shaped nanoparticles were shown to yield maximal enhancement values by an order of magnitude greater than their semi-ellipsoid-shaped counterparts; however, both nanoparticle shapes have demonstrated comparable effective electrical field enhancement values. Optimized Au nanostructures with equivalent diameters ranging from 85 to 143 nm and height equal to 35 nm were obtained for both techniques, resulting in the largest electrical field enhancement. The application of island film thermal annealing method for nanochips fabrication can be considered as a possible cost-effective platform for various surface-enhanced spectroscopies; while the NIL-fabricated NSA looks like more effective for sensing of small-size objects.

  4. Advanced hyphenated chromatographic-mass spectrometry in mycotoxin determination: current status and prospects.

    PubMed

    Li, Peiwu; Zhang, Zhaowei; Hu, Xiaofeng; Zhang, Qi

    2013-01-01

    Mass spectrometric techniques are essential for advanced research in food safety and environmental monitoring. These fields are important for securing the health of humans and animals, and for ensuring environmental security. Mycotoxins, toxic secondary metabolites of filamentous fungi, are major contaminants of agricultural products, food and feed, biological samples, and the environment as a whole. Mycotoxins can cause cancers, nephritic and hepatic diseases, various hemorrhagic syndromes, and immune and neurological disorders. Mycotoxin-contaminated food and feed can provoke trade conflicts, resulting in massive economic losses. Risk assessment of mycotoxin contamination for humans and animals generally depends on clear identification and reliable quantitation in diversified matrices. Pioneering work on mycotoxin quantitation using mass spectrometry (MS) was performed in the early 1970s. Now, unambiguous confirmation and quantitation of mycotoxins can be readily achieved with a variety hyphenated techniques that combine chromatographic separation with MS, including liquid chromatography (LC) or gas chromatography (GC). With the advent of atmospheric pressure ionization, LC-MS has become a routine technique. Recently, the co-occurrence of multiple mycotoxins in the same sample has drawn an increasing amount of attention. Thus, modern analyses must be able to detect and quantitate multiple mycotoxins in a single run. Improvements in tandem MS techniques have been made to achieve this purpose. This review describes the advanced research that has been done regarding mycotoxin determination using hyphenated chromatographic-MS techniques, but is not a full-circle survey of all the literature published on this topic. The present work provides an overview of the various hyphenated chromatographic-MS-based strategies that have been applied to mycotoxin analysis, with a focus on recent developments. The use of chromatographic-MS to measure levels of mycotoxins, including aflatoxins, ochratoxins, patulin, trichothecenes, zearalenone, and fumonisins, is discussed in detail. Both free and masked mycotoxins are included in this review due to different methods of sample preparation. Techniques are described in terms of sample preparation, internal standards, LC/ultra performance LC (UPLC) optimization, and applications and survey. Several future hyphenated MS techniques are discussed as well, including multidimensional chromatography-MS, capillary electrophoresis-MS, and surface plasmon resonance array-MS. © 2013 Wiley Periodicals, Inc.

  5. [Standardization of Blastocystis hominis diagnosis using different staining techniques].

    PubMed

    Eymael, Dayane; Schuh, Graziela Maria; Tavares, Rejane Giacomelli

    2010-01-01

    The present study was carried out from March to May 2008, with the aim of evaluating the effectiveness of different techniques for diagnosing Blastocystis hominis in a sample of the population attended at the Biomedicine Laboratory of Feevale University, Novo Hamburgo, Rio Grande do Sul. On hundred feces samples from children and adults were evaluated. After collection, the samples were subjected to the techniques of spontaneous sedimentation (HPJ), sedimentation in formalin-ether (Ritchie) and staining by means of Gram and May-Grünwald-Giemsa (MGG). The presence of Blastocystis hominis was observed in 40 samples, when staining techniques were used (MGG and Gram), while sedimentation techniques were less efficient (32 positive samples using the Ritchie technique and 20 positive samples using the HPJ technique). Our results demonstrate that HPJ was less efficient than the other methods, thus indicating the need to include laboratory techniques that enable parasite identification on a routine basis.

  6. Grain reconstruction of porous media: application to a low-porosity Fontainebleau sandstone.

    PubMed

    Thovert, J F; Yousefian, F; Spanne, P; Jacquin, C G; Adler, P M

    2001-06-01

    The fundamental issue of reconstructing a porous medium is examined anew in this paper, thanks to a sample of low-porosity Fontainebleau sandstone that has been analyzed by computed microtomography. Various geometric properties are determined on the experimental sample. A statistical property, namely, the probability density of the covering radius, is determined. This is used in order to reconstruct a porous medium by means of a Poissonian generation of polydisperse spheres. In a second part, the properties of the real experimental sample and of the reconstructed one are compared. The most important success of the present reconstruction technique is the fact that the numerical sample percolates despite its low porosity. Moreover, other geometrical features and conductivity are found to be in good agreement.

  7. Strategy to increase Barangan Banana production in Kabupaten Deli Serdang

    NASA Astrophysics Data System (ADS)

    Adhany, I.; Chalil, D.; Ginting, R.

    2018-02-01

    This study was conducted to analyze internal and external factors in increasing Barangan Banana production in Kabupaten Deli Serdang. Samples were determined by snowball sampling technique and purposive sampling method. Using SWOT analysis method, this study found that there were 6 internal strategic factors and 9 external strategic factors. Among that strategic factors, support for production facilities appears as the most important internal strategic factor, while the demand for Barangan Banana. as the most important external strategic factor. Based on the importance and existing condition of these strategic factors, using support for production facilities and realization of supporting facilities with farming experience are the strategies covering strength-opportunity (SO), organizing mentoring to meet the demand for Barangan Banana are the strategies covering weakness-opportunity (WO), making use of funding support and subsidies to widen the land, using tissue culture seeds and facilities and infrastructures are the strategies covering strength-threat (ST), increas the funding support to widen the land, the use of tissue culture seeds and facilities and infrastructures are the strategies covering weakness-threat (WT) are discussed and proposed to increase Barangan Banana productivity in Kabupaten Deli Serdang.

  8. Effects of forcefield and sampling method in all-atom simulations of inherently disordered proteins: Application to conformational preferences of human amylin

    PubMed Central

    Peng, Enxi; Todorova, Nevena

    2017-01-01

    Although several computational modelling studies have investigated the conformational behaviour of inherently disordered protein (IDP) amylin, discrepancies in identifying its preferred solution conformations still exist between various forcefields and sampling methods used. Human islet amyloid polypeptide has long been a subject of research, both experimentally and theoretically, as the aggregation of this protein is believed to be the lead cause of type-II diabetes. In this work, we present a systematic forcefield assessment using one of the most advanced non-biased sampling techniques, Replica Exchange with Solute Tempering (REST2), by comparing the secondary structure preferences of monomeric amylin in solution. This study also aims to determine the ability of common forcefields to sample a transition of the protein from a helical membrane bound conformation into the disordered solution state of amylin. Our results demonstrated that the CHARMM22* forcefield showed the best ability to sample multiple conformational states inherent for amylin. It is revealed that REST2 yielded results qualitatively consistent with experiments and in quantitative agreement with other sampling methods, however far more computationally efficiently and without any bias. Therefore, combining an unbiased sampling technique such as REST2 with a vigorous forcefield testing could be suggested as an important step in developing an efficient and robust strategy for simulating IDPs. PMID:29023509

  9. Effects of forcefield and sampling method in all-atom simulations of inherently disordered proteins: Application to conformational preferences of human amylin.

    PubMed

    Peng, Enxi; Todorova, Nevena; Yarovsky, Irene

    2017-01-01

    Although several computational modelling studies have investigated the conformational behaviour of inherently disordered protein (IDP) amylin, discrepancies in identifying its preferred solution conformations still exist between various forcefields and sampling methods used. Human islet amyloid polypeptide has long been a subject of research, both experimentally and theoretically, as the aggregation of this protein is believed to be the lead cause of type-II diabetes. In this work, we present a systematic forcefield assessment using one of the most advanced non-biased sampling techniques, Replica Exchange with Solute Tempering (REST2), by comparing the secondary structure preferences of monomeric amylin in solution. This study also aims to determine the ability of common forcefields to sample a transition of the protein from a helical membrane bound conformation into the disordered solution state of amylin. Our results demonstrated that the CHARMM22* forcefield showed the best ability to sample multiple conformational states inherent for amylin. It is revealed that REST2 yielded results qualitatively consistent with experiments and in quantitative agreement with other sampling methods, however far more computationally efficiently and without any bias. Therefore, combining an unbiased sampling technique such as REST2 with a vigorous forcefield testing could be suggested as an important step in developing an efficient and robust strategy for simulating IDPs.

  10. Evaluation of primary immunization coverage of infants under universal immunization programme in an urban area of bangalore city using cluster sampling and lot quality assurance sampling techniques.

    PubMed

    K, Punith; K, Lalitha; G, Suman; Bs, Pradeep; Kumar K, Jayanth

    2008-07-01

    Is LQAS technique better than cluster sampling technique in terms of resources to evaluate the immunization coverage in an urban area? To assess and compare the lot quality assurance sampling against cluster sampling in the evaluation of primary immunization coverage. Population-based cross-sectional study. Areas under Mathikere Urban Health Center. Children aged 12 months to 23 months. 220 in cluster sampling, 76 in lot quality assurance sampling. Percentages and Proportions, Chi square Test. (1) Using cluster sampling, the percentage of completely immunized, partially immunized and unimmunized children were 84.09%, 14.09% and 1.82%, respectively. With lot quality assurance sampling, it was 92.11%, 6.58% and 1.31%, respectively. (2) Immunization coverage levels as evaluated by cluster sampling technique were not statistically different from the coverage value as obtained by lot quality assurance sampling techniques. Considering the time and resources required, it was found that lot quality assurance sampling is a better technique in evaluating the primary immunization coverage in urban area.

  11. Autocorrelation of location estimates and the analysis of radiotracking data

    USGS Publications Warehouse

    Otis, D.L.; White, Gary C.

    1999-01-01

    The wildlife literature has been contradictory about the importance of autocorrelation in radiotracking data used for home range estimation and hypothesis tests of habitat selection. By definition, the concept of a home range involves autocorrelated movements, but estimates or hypothesis tests based on sampling designs that predefine a time frame of interest, and that generate representative samples of an animal's movement during this time frame, should not be affected by length of the sampling interval and autocorrelation. Intensive sampling of the individual's home range and habitat use during the time frame of the study leads to improved estimates for the individual, but use of location estimates as the sample unit to compare across animals is pseudoreplication. We therefore recommend against use of habitat selection analysis techniques that use locations instead of individuals as the sample unit. We offer a general outline for sampling designs for radiotracking studies.

  12. Respondent-driven sampling as Markov chain Monte Carlo.

    PubMed

    Goel, Sharad; Salganik, Matthew J

    2009-07-30

    Respondent-driven sampling (RDS) is a recently introduced, and now widely used, technique for estimating disease prevalence in hidden populations. RDS data are collected through a snowball mechanism, in which current sample members recruit future sample members. In this paper we present RDS as Markov chain Monte Carlo importance sampling, and we examine the effects of community structure and the recruitment procedure on the variance of RDS estimates. Past work has assumed that the variance of RDS estimates is primarily affected by segregation between healthy and infected individuals. We examine an illustrative model to show that this is not necessarily the case, and that bottlenecks anywhere in the networks can substantially affect estimates. We also show that variance is inflated by a common design feature in which the sample members are encouraged to recruit multiple future sample members. The paper concludes with suggestions for implementing and evaluating RDS studies.

  13. Breaking Out of the Lab: Measuring Real-Time Responses to Televised Political Content in Real-World Settings.

    PubMed

    Maier, Jürgen; Hampe, J Felix; Jahn, Nico

    2016-01-01

    Real-time response (RTR) measurement is an important technique for analyzing human processing of electronic media stimuli. Although it has been demonstrated that RTR data are reliable and internally valid, some argue that they lack external validity. The reason for this is that RTR measurement is restricted to a laboratory environment due to its technical requirements. This paper introduces a smartphone app that 1) captures real-time responses using the dial technique and 2) provides a solution for one of the most important problems in RTR measurement, the (automatic) synchronization of RTR data. In addition, it explores the reliability and validity of mobile RTR measurement by comparing the real-time reactions of two samples of young and well-educated voters to the 2013 German televised debate. Whereas the first sample participated in a classical laboratory study, the second sample was equipped with our mobile RTR system and watched the debate at home. Results indicate that the mobile RTR system yields similar results to the lab-based RTR measurement, providing evidence that laboratory studies using RTR are externally valid. In particular, the argument that the artificial reception situation creates artificial results has to be questioned. In addition, we conclude that RTR measurement outside the lab is possible. Hence, mobile RTR opens the door for large-scale studies to better understand the processing and impact of electronic media content.

  14. Breaking Out of the Lab

    PubMed Central

    Maier, Jürgen; Hampe, J. Felix; Jahn, Nico

    2016-01-01

    Real-time response (RTR) measurement is an important technique for analyzing human processing of electronic media stimuli. Although it has been demonstrated that RTR data are reliable and internally valid, some argue that they lack external validity. The reason for this is that RTR measurement is restricted to a laboratory environment due to its technical requirements. This paper introduces a smartphone app that 1) captures real-time responses using the dial technique and 2) provides a solution for one of the most important problems in RTR measurement, the (automatic) synchronization of RTR data. In addition, it explores the reliability and validity of mobile RTR measurement by comparing the real-time reactions of two samples of young and well-educated voters to the 2013 German televised debate. Whereas the first sample participated in a classical laboratory study, the second sample was equipped with our mobile RTR system and watched the debate at home. Results indicate that the mobile RTR system yields similar results to the lab-based RTR measurement, providing evidence that laboratory studies using RTR are externally valid. In particular, the argument that the artificial reception situation creates artificial results has to be questioned. In addition, we conclude that RTR measurement outside the lab is possible. Hence, mobile RTR opens the door for large-scale studies to better understand the processing and impact of electronic media content. PMID:27274577

  15. Directional selection in temporally replicated studies is remarkably consistent.

    PubMed

    Morrissey, Michael B; Hadfield, Jarrod D

    2012-02-01

    Temporal variation in selection is a fundamental determinant of evolutionary outcomes. A recent paper presented a synthetic analysis of temporal variation in selection in natural populations. The authors concluded that there is substantial variation in the strength and direction of selection over time, but acknowledged that sampling error would result in estimates of selection that were more variable than the true values. We reanalyze their dataset using techniques that account for the necessary effect of sampling error to inflate apparent levels of variation and show that directional selection is remarkably constant over time, both in magnitude and direction. Thus we cannot claim that the available data support the existence of substantial temporal heterogeneity in selection. Nonetheless, we conject that temporal variation in selection could be important, but that there are good reasons why it may not appear in the available data. These new analyses highlight the importance of applying techniques that estimate parameters of the distribution of selection, rather than parameters of the distribution of estimated selection (which will reflect both sampling error and "real" variation in selection); indeed, despite availability of methods for the former, focus on the latter has been common in synthetic reviews of the aspects of selection in nature, and can lead to serious misinterpretations. © 2011 The Author(s). Evolution© 2011 The Society for the Study of Evolution.

  16. Selecting Strategies to Reduce High-Risk Unsafe Work Behaviors Using the Safety Behavior Sampling Technique and Bayesian Network Analysis.

    PubMed

    Ghasemi, Fakhradin; Kalatpour, Omid; Moghimbeigi, Abbas; Mohammadfam, Iraj

    2017-03-04

    High-risk unsafe behaviors (HRUBs) have been known as the main cause of occupational accidents. Considering the financial and societal costs of accidents and the limitations of available resources, there is an urgent need for managing unsafe behaviors at workplaces. The aim of the present study was to find strategies for decreasing the rate of HRUBs using an integrated approach of safety behavior sampling technique and Bayesian networks analysis. A cross-sectional study. The Bayesian network was constructed using a focus group approach. The required data was collected using the safety behavior sampling, and the parameters of the network were estimated using Expectation-Maximization algorithm. Using sensitivity analysis and belief updating, it was determined that which factors had the highest influences on unsafe behavior. Based on BN analyses, safety training was the most important factor influencing employees' behavior at the workplace. High quality safety training courses can reduce the rate of HRUBs about 10%. Moreover, the rate of HRUBs increased by decreasing the age of employees. The rate of HRUBs was higher in the afternoon and last days of a week. Among the investigated variables, training was the most important factor affecting safety behavior of employees. By holding high quality safety training courses, companies would be able to reduce the rate of HRUBs significantly.

  17. Serum and Plasma Metabolomic Biomarkers for Lung Cancer.

    PubMed

    Kumar, Nishith; Shahjaman, Md; Mollah, Md Nurul Haque; Islam, S M Shahinul; Hoque, Md Aminul

    2017-01-01

    In drug invention and early disease prediction of lung cancer, metabolomic biomarker detection is very important. Mortality rate can be decreased, if cancer is predicted at the earlier stage. Recent diagnostic techniques for lung cancer are not prognosis diagnostic techniques. However, if we know the name of the metabolites, whose intensity levels are considerably changing between cancer subject and control subject, then it will be easy to early diagnosis the disease as well as to discover the drug. Therefore, in this paper we have identified the influential plasma and serum blood sample metabolites for lung cancer and also identified the biomarkers that will be helpful for early disease prediction as well as for drug invention. To identify the influential metabolites, we considered a parametric and a nonparametric test namely student׳s t-test as parametric and Kruskal-Wallis test as non-parametric test. We also categorized the up-regulated and down-regulated metabolites by the heatmap plot and identified the biomarkers by support vector machine (SVM) classifier and pathway analysis. From our analysis, we got 27 influential (p-value<0.05) metabolites from plasma sample and 13 influential (p-value<0.05) metabolites from serum sample. According to the importance plot through SVM classifier, pathway analysis and correlation network analysis, we declared 4 metabolites (taurine, aspertic acid, glutamine and pyruvic acid) as plasma biomarker and 3 metabolites (aspartic acid, taurine and inosine) as serum biomarker.

  18. Faster the better: a reliable technique to sample anopluran lice in large hosts.

    PubMed

    Leonardi, María Soledad

    2014-06-01

    Among Anoplura, the family Echinophthiriidae includes those species that infest mainly the pinnipeds. Working with large hosts implies methodological considerations as the time spent in the sampling, and the way in that the animal is restrained. Previous works on echinophthiriids combined a diverse array of analyses including field counts of lice and in vitro observations. To collect lice, the authors used forceps, and each louse was collected individually. This implied a long manipulation time, i.e., ≈60 min and the need to physically and/or chemically immobilize the animal. The present work described and discussed for the first a sample technique that minimized the manipulation time and also avoiding the use of anesthesia. This methodology implied combing the host's pelage with a fine-tooth plastic comb, as used in the treatment of human pediculosis, and keeping the comb with the lice retained in a Ziploc® bag with ethanol. This technique was used successfully in studies of population dynamic, habitat selection, and transmission pattern, being a reliable methodology. Lice are collected entirely and are in a good condition to prepare them for mounting for studying under light or scanning electron microscopy. Moreover, the use of the plastic comb protects from damaging taxonomically important structures as spines being also recommended to reach taxonomic or morphological goals.

  19. Searching for chemical classes among metal-poor stars using medium-resolution spectroscopy

    NASA Astrophysics Data System (ADS)

    Cruz, Monique A.; Cogo-Moreira, Hugo; Rossi, Silvia

    2018-04-01

    Astronomy is in the era of large spectroscopy surveys, with the spectra of hundreds of thousands of stars in the Galaxy being collected. Although most of these surveys have low or medium resolution, which makes precise abundance measurements not possible, there is still important information to be extracted from the available data. Our aim is to identify chemically distinct classes among metal-poor stars, observed by the Sloan Digital Sky Survey, using line indices. The present work focused on carbon-enhanced metal-poor (CEMP) stars and their subclasses. We applied the latent profile analysis technique to line indices for carbon, barium, iron and europium, in order to separate the sample into classes with similar chemical signatures. This technique provides not only the number of possible groups but also the probability of each object to belong to each class. The method was able to distinguish at least two classes among the observed sample, with one of them being probable CEMP stars enriched in s-process elements. However, it was not able to separate CEMP-no stars from the rest of the sample. Latent profile analysis is a powerful model-based tool to be used in the identification of patterns in astrophysics. Our tests show the potential of the technique for the attainment of additional chemical information from `poor' data.

  20. Bright field segmentation tomography (BFST) for use as surface identification in stereomicroscopy

    NASA Astrophysics Data System (ADS)

    Thiesse, Jacqueline R.; Namati, Eman; de Ryk, Jessica; Hoffman, Eric A.; McLennan, Geoffrey

    2004-07-01

    Stereomicroscopy is an important method for use in image acquisition because it provides a 3D image of an object when other microscopic techniques can only provide the image in 2D. One challenge that is being faced with this type of imaging is determining the top surface of a sample that has otherwise indistinguishable surface and planar characteristics. We have developed a system that creates oblique illumination and in conjunction with image processing, the top surface can be viewed. The BFST consists of the Leica MZ12 stereomicroscope with a unique attached lighting source. The lighting source consists of eight light emitting diodes (LED's) that are separated by 45-degree angles. Each LED in this system illuminates with a 20-degree viewing angle once per cycle with a shadow over the rest of the sample. Subsequently, eight segmented images are taken per cycle. After the images are captured they are stacked through image addition to achieve the full field of view, and the surface is then easily identified. Image processing techniques, such as skeletonization can be used for further enhancement and measurement. With the use of BFST, advances can be made in detecting surface features from metals to tissue samples, such as in the analytical assessment of pulmonary emphysema using the technique of mean linear intercept.

  1. Medical Products Research

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Ventrex Laboratories, Inc. develops, manufactures and markets a line of medical diagnostic assays based on biochemical techniques, in particular immunochemical techniques. Their products are sold worldwide to hospitals and medical laboratories for use in testing blood samples and other biological fluids. Analysis of a patient's body fluids, compared with normal values, aids a physician in confirming or otherwise diagnosing a suspected disease condition. NERAC's rapid information retrieval has provided Ventrex invaluable up-to-date information, and has permitted large scale savings. NERAC's service was particularly important in the development of a new product in the company's Ventre/Sep line, which is used in radioimmunoassays.

  2. Human and Methodological Sources of Variability in the Measurement of Urinary 8-Oxo-7,8-dihydro-2′-deoxyguanosine

    PubMed Central

    Møller, Peter; Henriksen, Trine; Mistry, Vilas; Koppen, Gudrun; Rossner, Pavel; Sram, Radim J.; Weimann, Allan; Poulsen, Henrik E.; Nataf, Robert; Andreoli, Roberta; Manini, Paola; Marczylo, Tim; Lam, Patricia; Evans, Mark D.; Kasai, Hiroshi; Kawai, Kazuaki; Li, Yun-Shan; Sakai, Kazuo; Singh, Rajinder; Teichert, Friederike; Farmer, Peter B.; Rozalski, Rafal; Gackowski, Daniel; Siomek, Agnieszka; Saez, Guillermo T.; Cerda, Concha; Broberg, Karin; Lindh, Christian; Hossain, Mohammad Bakhtiar; Haghdoost, Siamak; Hu, Chiung-Wen; Chao, Mu-Rong; Wu, Kuen-Yuh; Orhan, Hilmi; Senduran, Nilufer; Smith, Raymond J.; Santella, Regina M.; Su, Yali; Cortez, Czarina; Yeh, Susan; Olinski, Ryszard; Loft, Steffen

    2013-01-01

    Abstract Aims: Urinary 8-oxo-7,8-dihydro-2′-deoxyguanosine (8-oxodG) is a widely used biomarker of oxidative stress. However, variability between chromatographic and ELISA methods hampers interpretation of data, and this variability may increase should urine composition differ between individuals, leading to assay interference. Furthermore, optimal urine sampling conditions are not well defined. We performed inter-laboratory comparisons of 8-oxodG measurement between mass spectrometric-, electrochemical- and ELISA-based methods, using common within-technique calibrants to analyze 8-oxodG-spiked phosphate-buffered saline and urine samples. We also investigated human subject- and sample collection-related variables, as potential sources of variability. Results: Chromatographic assays showed high agreement across urines from different subjects, whereas ELISAs showed far more inter-laboratory variation and generally overestimated levels, compared to the chromatographic assays. Excretion rates in timed ‘spot’ samples showed strong correlations with 24 h excretion (the ‘gold’ standard) of urinary 8-oxodG (rp 0.67–0.90), although the associations were weaker for 8-oxodG adjusted for creatinine or specific gravity (SG). The within-individual excretion of 8-oxodG varied only moderately between days (CV 17% for 24 h excretion and 20% for first void, creatinine-corrected samples). Innovation: This is the first comprehensive study of both human and methodological factors influencing 8-oxodG measurement, providing key information for future studies with this important biomarker. Conclusion: ELISA variability is greater than chromatographic assay variability, and cannot determine absolute levels of 8-oxodG. Use of standardized calibrants greatly improves intra-technique agreement and, for the chromatographic assays, importantly allows integration of results for pooled analyses. If 24 h samples are not feasible, creatinine- or SG-adjusted first morning samples are recommended. Antioxid. Redox Signal. 18, 2377–2391. PMID:23198723

  3. Laser cleaning of steel for paint removal

    NASA Astrophysics Data System (ADS)

    Chen, G. X.; Kwee, T. J.; Tan, K. P.; Choo, Y. S.; Hong, M. H.

    2010-11-01

    Paint removal is an important part of steel processing for marine and offshore engineering. For centuries, a blasting techniques have been widely used for this surface preparation purpose. But conventional blasting always has intrinsic problems, such as noise, explosion risk, contaminant particles, vibration, and dust. In addition, processing wastes often cause environmental problems. In recent years, laser cleaning has attracted much research effort for its significant advantages, such as precise treatment, and high selectivity and flexibility in comparison with conventional cleaning techniques. In the present study, we use this environmentally friendly technique to overcome the problems of conventional blasting. Processed samples are examined with optical microscopes and other surface characterization tools. Experimental results show that laser cleaning can be a good alternative candidate to conventional blasting.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hiller, Mauritius M.; Veinot, Kenneth G.; Easterly, Clay E.

    In this study, methods are addressed to reduce the computational time to compute organ-dose rate coefficients using Monte Carlo techniques. Several variance reduction techniques are compared including the reciprocity method, importance sampling, weight windows and the use of the ADVANTG software package. For low-energy photons, the runtime was reduced by a factor of 10 5 when using the reciprocity method for kerma computation for immersion of a phantom in contaminated water. This is particularly significant since impractically long simulation times are required to achieve reasonable statistical uncertainties in organ dose for low-energy photons in this source medium and geometry. Althoughmore » the MCNP Monte Carlo code is used in this paper, the reciprocity technique can be used equally well with other Monte Carlo codes.« less

  5. Monitoring of Lactic Fermentation Process by Ultrasonic Technique

    NASA Astrophysics Data System (ADS)

    Alouache, B.; Touat, A.; Boutkedjirt, T.; Bennamane, A.

    The non-destructive control by using ultrasound techniques has become of great importance in food industry. In this work, Ultrasound has been used for quality control and monitoring the fermentation stages of yogurt, which is a highly consumed product. On the contrary to the physico-chemical methods, where the measurement instruments are directly introduced in the sample, ultrasound techniques have the advantage of being non-destructive and contactless, thus reducing the risk of contamination. Results obtained in this study by using ultrasound seem to be in good agreement with those obtained by physico-chemical methods such as acidity measurement by using a PH-meter instrument. This lets us to conclude that ultrasound method may be an alternative for a healthy control of yoghurt fermentation process.

  6. Community, environmental, and occupational health risks associated with fossil fuel energy production

    NASA Astrophysics Data System (ADS)

    Shepherd, Mark A.

    Short-term and long-term health risks associated with fossil fuel power production can be grouped into three broad categories: risks to the surrounding community, the natural environment and to plant workers. The results of three studies examining the primary short-term or long-term impacts of fossil fuel power plants are presented within this dissertation. The first study estimates the plausible community health effects associated with peak SO2 emissions from three coal-fired power plants in the Baltimore, Maryland area. Concentrations from mobile and stationary air monitoring were compared to human clinical studies that demonstrated respiratory morbidity. Results indicate that exposure concentrations are below levels associated with respiratory symptoms. A single measurement at one monitoring site, however, may indicate risk of asymptomatic lung function decrement for SO2-sensitive asthmatics. The second study estimates the relationship between operational, environmental and temporal factors at a Texas coastal power plant and fish and shellfish impingement. Impingement is a long-term risk to fish populations near power plants. When large quantities of water are withdrawn from water bodies for cooling, fish and shellfish may be harmed if impinged against screens intended to remove debris. In this study, impingement of fish and shellfish was best explained by dissolved oxygen concentration, sampling month and sampling time. When examined separately, temperature and sampling month were most important in explaining fish impingement, while for shellfish, sampling month and sampling time were most important. Operational factors were not significant predictors of impingement. The third study examines whether the number of worker similar exposure groups classified using observation methods was the same as groups classified using personal exposure monitoring. Using observational techniques and personal monitoring, power plant workers were grouped according to exposure similarity for respirable silica, respirable particulates, total dust, chromium and arsenic. For respirable particulates, the number of groups estimated using observational techniques is similar to the number estimated using personal monitoring. For respirable silica, total dust, and arsenic, observational techniques indicated more groups than indicated using personal monitoring. No significant exposure differences to chromium were found. Except for respirable silica, the number of similarly exposed groups among power plants is comparable.

  7. Small-scale thermal studies of volatile homemade explosives

    DOE PAGES

    Sandstrom, Mary M.; Brown, Geoffrey W.; Warner, Kirsten F.; ...

    2016-01-26

    Several homemade or improvised explosive mixtures that either contained volatile components or produced volatile products were examined using standard small-scale safety and thermal (SSST) testing that employed differential scanning calorimetry (DSC) techniques (constant heating rate and standard sample holders). KClO 3 and KClO 4 mixtures with dodecane exhibited different enthalpy behavior when using a vented sample holder in contrast to a sealed sample holder. The standard configuration produced profiles that exhibited only endothermic transitions. The sealed system produced profiles that exhibited additional exothermic transitions absent in the standard configuration produced profiles. When H 2O 2/fuel mixtures were examined, the volatilizationmore » of the peroxide (endothermic) dominated the profiles. When a sealed sample holder was used, the energetic releases of the mixture could be clearly observed. For AN and AN mixtures, the high temperature decomposition appears as an intense endothermic event. Using a nominally sealed sample holder also did not adequately contain the system. Only when a high-pressure rated sample holder was used the high temperature decomposition of the AN could be detected as an exothermic release. The testing was conducted during a proficiency (or round-robin type) test that included three U.S. Department of Energy and two U.S. Department of Defense laboratories. In the course of this proficiency test, certain HMEs exhibited thermal behavior that was not adequately accounted for by standard techniques. Further examination of this atypical behavior highlighted issues that may have not been recognized previously because some of these materials are not routinely tested. More importantly, if not recognized, the SSST testing results could lead to inaccurate safety assessments. Furthermore, this study provides examples, where standard techniques can be applied, and results can be obtained, but these results may be misleading in establishing thermal properties.« less

  8. The ultrastructure of subgingival dental plaque, revealed by high-resolution field emission scanning electron microscopy.

    PubMed

    Holliday, Richard; Preshaw, Philip M; Bowen, Leon; Jakubovics, Nicholas S

    2015-01-01

    To explore the ultrastructure of subgingival dental plaque using high-resolution field emission scanning electron microscopy (FE-SEM) and to investigate whether extracellular DNA (eDNA) could be visualised in ex vivo samples. Ten patients were recruited who fulfilled the inclusion criteria (teeth requiring extraction with radiographic horizontal bone loss of over 50% and grade II/III mobility). In total, 12 teeth were extracted using a minimally traumatic technique. Roots were sectioned using a dental air turbine handpiece, under water cooling to produce 21 samples. Standard fixation and dehydration protocols were followed. For some samples, gold-labelled anti-DNA antibodies were applied before visualising biofilms by FE-SEM. High-resolution FE-SEMs of subgingival biofilm were obtained in 90% of the samples. The sectioning technique left dental plaque biofilms undisturbed. Copious amounts of extracellular material were observed in the plaque, which may have been eDNA as they had a similar appearance to labelled eDNA from in vitro studies. There was also evidence of membrane vesicles and open-ended tubular structures. Efforts to label eDNA with immune-gold antibodies were unsuccessful and eDNA was not clearly labelled. High-resolution FE-SEM images were obtained of undisturbed subgingival ex vivo dental plaque biofilms. Important structural features were observed including extracellular polymeric material, vesicles and unusual open tubule structures that may be remnants of lysed cells. The application of an eDNA immune-gold-labelling technique, previously used successfully in in vitro samples, did not clearly identify eDNA in ex vivo samples. Further studies are needed to characterise the molecular composition of the observed extracellular matrix material.

  9. The ultrastructure of subgingival dental plaque, revealed by high-resolution field emission scanning electron microscopy

    PubMed Central

    Holliday, Richard; Preshaw, Philip M; Bowen, Leon; Jakubovics, Nicholas S

    2015-01-01

    Objectives/Aims: To explore the ultrastructure of subgingival dental plaque using high-resolution field emission scanning electron microscopy (FE-SEM) and to investigate whether extracellular DNA (eDNA) could be visualised in ex vivo samples. Materials and Methods: Ten patients were recruited who fulfilled the inclusion criteria (teeth requiring extraction with radiographic horizontal bone loss of over 50% and grade II/III mobility). In total, 12 teeth were extracted using a minimally traumatic technique. Roots were sectioned using a dental air turbine handpiece, under water cooling to produce 21 samples. Standard fixation and dehydration protocols were followed. For some samples, gold-labelled anti-DNA antibodies were applied before visualising biofilms by FE-SEM. Results: High-resolution FE-SEMs of subgingival biofilm were obtained in 90% of the samples. The sectioning technique left dental plaque biofilms undisturbed. Copious amounts of extracellular material were observed in the plaque, which may have been eDNA as they had a similar appearance to labelled eDNA from in vitro studies. There was also evidence of membrane vesicles and open-ended tubular structures. Efforts to label eDNA with immune-gold antibodies were unsuccessful and eDNA was not clearly labelled. Conclusions: High-resolution FE-SEM images were obtained of undisturbed subgingival ex vivo dental plaque biofilms. Important structural features were observed including extracellular polymeric material, vesicles and unusual open tubule structures that may be remnants of lysed cells. The application of an eDNA immune-gold-labelling technique, previously used successfully in in vitro samples, did not clearly identify eDNA in ex vivo samples. Further studies are needed to characterise the molecular composition of the observed extracellular matrix material. PMID:29607057

  10. Fatty Acid Composition of Human Follicular Fluid Phospholipids and Fertilization Rate in Assisted Reproductive Techniques

    PubMed Central

    Shaaker, Maghsod; Rahimipour, Ali; Nouri, Mohammad; Khanaki, Korosh; Darabi, Masoud; Farzadi, Laya; Shahnazi, Vahideh; Mehdizadeh, Amir

    2012-01-01

    Background: Fatty acids are known to be critically important in multiple biological functions. Phospholipid fatty acids of follicular fluid, an important microenvironment for the development of oocytes, may contribute to the women’s fertility and the efficacy of assisted reproduction techniques. The aim of this study was to investigate the effect of fatty acid composition of follicular fluid phospholipids on women undergoing assisted reproductive techniques. Methods: Follicular fluid samples were obtained from 100 patients, referred to Tabriz Alzahra Hospital. Seventy-nine subjects underwent in vitro fertilization (IVF) and the remaining 21 underwent intracytoplasmic sperm injection (ICSI). Total lipid of follicular fluid was extracted and fatty acids were analyzed by gas-liquid chromatography. Results: Saturated fatty acids (SFA, P = 0.002) and the ratio of SFA to polyunsaturated fatty acids (P = 0.001) were correlated negatively with a number of mature oocytes after age adjustment. Linoleic acid (P = 0.006) was positively correlated, while the level of arachidonic acid was negatively correlated with fertility percentage after adjustment for body mass index, sperm count, sperm motility. Conclusion: Since phospholipids are one of the major components of lipid metabolism, the results of this study highlight the importance of this component in follicular fluid lipid metabolism. Consequently, it is proposed as an index in determination of the rate of success in assisted reproductive techniques such as IVF/ICSI. PMID:23023218

  11. Evaluation of Primary Immunization Coverage of Infants Under Universal Immunization Programme in an Urban Area of Bangalore City Using Cluster Sampling and Lot Quality Assurance Sampling Techniques

    PubMed Central

    K, Punith; K, Lalitha; G, Suman; BS, Pradeep; Kumar K, Jayanth

    2008-01-01

    Research Question: Is LQAS technique better than cluster sampling technique in terms of resources to evaluate the immunization coverage in an urban area? Objective: To assess and compare the lot quality assurance sampling against cluster sampling in the evaluation of primary immunization coverage. Study Design: Population-based cross-sectional study. Study Setting: Areas under Mathikere Urban Health Center. Study Subjects: Children aged 12 months to 23 months. Sample Size: 220 in cluster sampling, 76 in lot quality assurance sampling. Statistical Analysis: Percentages and Proportions, Chi square Test. Results: (1) Using cluster sampling, the percentage of completely immunized, partially immunized and unimmunized children were 84.09%, 14.09% and 1.82%, respectively. With lot quality assurance sampling, it was 92.11%, 6.58% and 1.31%, respectively. (2) Immunization coverage levels as evaluated by cluster sampling technique were not statistically different from the coverage value as obtained by lot quality assurance sampling techniques. Considering the time and resources required, it was found that lot quality assurance sampling is a better technique in evaluating the primary immunization coverage in urban area. PMID:19876474

  12. [The diagnosis of malaria by the thick film and the QBC: a comparative study of both technics].

    PubMed

    Cabezos, J; Bada, J L

    1993-06-12

    The diagnosis of paludism is important because of the severity of the clinical picture caused by Plasmodium falciparum, the increasing number of travellers to endemic zones and the emigration from these zones. A comparative study of the QBC techniques (staining with acridin orange and observation with ultraviolet light) and the thick film with Giemsa staining was carried out. The QBC and thick film were performed parallelly for 17 months in a total of 623 samples pertaining to subjects from endemic zones of paludism (emigrants, immigrants and travellers). Of the 623 samples studied 49 were positive for paludism by both techniques. Ten were positive with only the thick film and six were positive only with QBC. The sensitivity of QBC versus thick film was 83% and specificity 98.9%. The time used to determine diagnosis with the QBC technique ranged from 6 to 12 minutes from withdrawal of the sample, while with the thick film the time spent was more than 2 hours. The cases positive by thick film and negative with QBC corresponded to patients with very low parasitation. The intensity of parasitation was difficult to determine quantitatively by QBC. Although the QBC technique has the advantage of speed it is inexact with respect to the quantification of parasitemia. Moreover, it is less sensitive than the thick film in patient with very low parasitations and cannot thus substitute the thick film.

  13. Determination and health risk assessment of enrofloxacin, flumequine and sulfamethoxazole in imported Pangasius catfish products in Thailand.

    PubMed

    Jansomboon, Worawat; Boontanon, Suwanna Kitpati; Boontanon, Narin; Polprasert, Chongrak

    2018-02-01

    The goals of this study were to determine the levels of three antibiotics - enrofloxacin, flumequine and sulfamethoxazole - in Pangasius catfish products imported into Thailand and to assess the health risks from consumption. To extract these antibiotic residues, acetonitrile, methanol and a small amount of formic acid were used as solvents. Determination of the antibiotics after extraction steps was carried out by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) technique. The results showed that 14 and 3 samples of Pangasius catfish products were contaminated with enrofloxacin and sulfamethoxazole, respectively. No flumequine residue was found. While the concentration levels of these antibiotics in most contaminated samples were lower than the European Union (EU) standard, one sample was found to contain sulfamethoxazole at 245.91 µg kg -1 , which was higher than the EU standard (100 µg kg -1 ), indicating the likelihood that some contaminated freshwater fish products are widely distributed in Thai markets. Notably, the concentration levels of enrofloxacin in samples of Pangasius catfish with skin were higher than in non-skin products, suggesting that products with skin might retain more antibiotic residues than non-skin products. Although the hazard quotient showed that consuming imported Pangasius catfish products, based on the current consumption rate, will not adversely affect consumer health, antibiotic residues in Pangasius catfish products imported into Thailand should be continually monitored.

  14. Characterization of polymorphic states in energetic samples of 1,3,5-trinitro-1,3,5-triazine (RDX) fabricated using drop-on-demand inkjet technology.

    PubMed

    Emmons, Erik D; Farrell, Mikella E; Holthoff, Ellen L; Tripathi, Ashish; Green, Norman; Moon, Raphael P; Guicheteau, Jason A; Christesen, Steven D; Pellegrino, Paul M; Fountain, Augustus W

    2012-06-01

    The United States Army and the first responder community are evaluating optical detection systems for the trace detection of hazardous energetic materials. Fielded detection systems must be evaluated with the appropriate material concentrations to accurately identify the residue in theater. Trace levels of energetic materials have been observed in mutable polymorphic phases and, therefore, the systems being evaluated must be able to detect and accurately identify variant sample phases observed in spectral data. In this work, we report on the novel application of drop-on-demand technology for the fabrication of standardized trace 1,3,5-trinitro-1,3,5-triazine (RDX) samples. The drop-on-demand sample fabrication technique is compared both visually and spectrally to the more commonly used drop-and-dry technique. As the drop-on-demand technique allows for the fabrication of trace level hazard materials, concerted efforts focused on characterization of the polymorphic phase changes observed with low concentrations of RDX commonly used in drop-on-demand processing. This information is important when evaluating optical detection technologies using samples prepared with a drop-on-demand inkjet system, as the technology may be "trained" to detect the common bulk α phase of the explosive based on its spectral features but fall short in positively detecting a trace quantity of RDX (β-phase). We report the polymorphic shifts observed between α- and β-phases of this energetic material and discuss the conditions leading to the favoring of one phase over the other.

  15. Electrical field-induced extraction and separation techniques: promising trends in analytical chemistry--a review.

    PubMed

    Yamini, Yadollah; Seidi, Shahram; Rezazadeh, Maryam

    2014-03-03

    Sample preparation is an important issue in analytical chemistry, and is often a bottleneck in chemical analysis. So, the major incentive for the recent research has been to attain faster, simpler, less expensive, and more environmentally friendly sample preparation methods. The use of auxiliary energies, such as heat, ultrasound, and microwave, is one of the strategies that have been employed in sample preparation to reach the above purposes. Application of electrical driving force is the current state-of-the-art, which presents new possibilities for simplifying and shortening the sample preparation process as well as enhancing its selectivity. The electrical driving force has scarcely been utilized in comparison with other auxiliary energies. In this review, the different roles of electrical driving force (as a powerful auxiliary energy) in various extraction techniques, including liquid-, solid-, and membrane-based methods, have been taken into consideration. Also, the references have been made available, relevant to the developments in separation techniques and Lab-on-a-Chip (LOC) systems. All aspects of electrical driving force in extraction and separation methods are too specific to be treated in this contribution. However, the main aim of this review is to provide a brief knowledge about the different fields of analytical chemistry, with an emphasis on the latest efforts put into the electrically assisted membrane-based sample preparation systems. The advantages and disadvantages of these approaches as well as the new achievements in these areas have been discussed, which might be helpful for further progress in the future. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. A guide to large-scale RNA sample preparation.

    PubMed

    Baronti, Lorenzo; Karlsson, Hampus; Marušič, Maja; Petzold, Katja

    2018-05-01

    RNA is becoming more important as an increasing number of functions, both regulatory and enzymatic, are being discovered on a daily basis. As the RNA boom has just begun, most techniques are still in development and changes occur frequently. To understand RNA functions, revealing the structure of RNA is of utmost importance, which requires sample preparation. We review the latest methods to produce and purify a variation of RNA molecules for different purposes with the main focus on structural biology and biophysics. We present a guide aimed at identifying the most suitable method for your RNA and your biological question and highlighting the advantages of different methods. Graphical abstract In this review we present different methods for large-scale production and purification of RNAs for structural and biophysical studies.

  17. An Important Stage of Life-Long Learning: Adult Literacy and Benefits (Sampling of Kayseri in Turkey)

    ERIC Educational Resources Information Center

    Göçer, Ali

    2016-01-01

    The purpose of this research is to provide an overview of adult literacy within the framework of lifelong learning in Turkey. Triangulation technique is applied with the approach of qualitative research, and within this framework, document review, interviews and observations were made. The research was carried out in a workgroup. These working…

  18. Thin sectioning and surface replication of ice at low temperature.

    USGS Publications Warehouse

    Daley, M.A.; Kirby, S.H.

    1984-01-01

    We have developed a new technique for making thin sections and surface replicas of ice at temperatures well below 273d K. The ability to make thin sections without melting sample material is important in textural and microstructural studies of ice deformed at low temperatures because of annealing effects we have observed during conventional section making.-from Author

  19. Polyelectrolyte assisted charge titration spectrometry: Applications to latex and oxide nanoparticles.

    PubMed

    Mousseau, F; Vitorazi, L; Herrmann, L; Mornet, S; Berret, J-F

    2016-08-01

    The electrostatic charge density of particles is of paramount importance for the control of the dispersion stability. Conventional methods use potentiometric, conductometric or turbidity titration but require large amount of samples. Here we report a simple and cost-effective method called polyelectrolyte assisted charge titration spectrometry or PACTS. The technique takes advantage of the propensity of oppositely charged polymers and particles to assemble upon mixing, leading to aggregation or phase separation. The mixed dispersions exhibit a maximum in light scattering as a function of the volumetric ratio X, and the peak position XMax is linked to the particle charge density according to σ∼D0XMax where D0 is the particle diameter. The PACTS is successfully applied to organic latex, aluminum and silicon oxide particles of positive or negative charge using poly(diallyldimethylammonium chloride) and poly(sodium 4-styrenesulfonate). The protocol is also optimized with respect to important parameters such as pH and concentration, and to the polyelectrolyte molecular weight. The advantages of the PACTS technique are that it requires minute amounts of sample and that it is suitable to a broad variety of charged nano-objects. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Antimicrobial Susceptibility of Tinea Capitis in Children from Egypt

    PubMed Central

    Doss, Reham William; El-Rifaie, Abdel-Aziz; Radi, Nagla; El-Sherif, Aya Yehia

    2018-01-01

    Background: Dermatophytic fungi of genera Trichophyton and Microsporum are the most important fungal species causing tinea capitis. Choice of treatment for tinea capitis is determined by the species of fungus. Aim: The aim of the study was to investigate the most prevalent fungal species causing tinea capitis in children from Egypt and the most useful antifungal agent for treatment. Patients and Methods: A total of 100 patients diagnosed clinically with tinea capitis were included in the study. Samples were collected and sent to the microbiology and immunology laboratory for sample processing and fungal identification by routine laboratory techniques. A study of antifungal susceptibility to chosen antifungal medications (fluconazole, ketoconazole, clotrimazole, miconazole, amphotericin, caspofungin, itraconazole, terbinafine, and griseofulvin) was done by minimum inhibitory concentration technique. Results: Our analysis revealed that Microsporum canis is the most commonly isolated strain. Amphotericin was the most effective antifungal agent followed by terbinafine. The most sensitive strain to fluconazole and griseofulvin is Microsporum gypseum, while Microsporum audouinii was mostly responsive to terbinafine. Conclusion: Identification and evaluation of the antifungal susceptibility of the pathogenic species in a certain geographic region is important to achieve a good clinical response. PMID:29692458

  1. Preparation and magnetic properties of the Sr-hexaferrite with foam structure

    NASA Astrophysics Data System (ADS)

    Guerrero, A. L.; Espericueta, D. L.; Palomares-Sánchez, S. A.; Elizalde-Galindo, J. T.; Watts, B. E.; Mirabal-García, M.

    2016-12-01

    This work reports an optimal way to fabricate strontium hexaferrite with porous-reticulated structure using a variation of the replication technique and taking two different precursors, one obtained from the coprecipitation and the other from the ceramic method. Changes made to the original replication technique include the addition of Arabic gum as binder, and the addition of ethylene glycol to form the ceramic sludge. In addition, some parameters such as the relation between solid material and liquid phase, the quantity of binder and the heat treatment were varied to obtain high quality magnetic foams. Two polymeric sponges were used as patterns, one with average pore size of 300 μm diameter and the other with 1100 μm. The characterization of the samples included the analysis of the structure and phase purity, the magnetic properties, the remanence properties, magnetic interactions and the microstructural characteristics. Results indicate that both, the powder precursors and the polymeric pattern play an important role in the configuration of the foam structure and this configuration has an important influence on the dipolar interactions which tend to demagnetize the samples. In addition, it was analyzed the behavior between the minimum value of the δM curves and the hysteresis properties.

  2. FTIR and NDIR spectroscopies as valuable alternatives to IRMS spectrometry for the δ(13)C analysis of food.

    PubMed

    Pironti, Concetta; Proto, Antonio; Camin, Federica; Cucciniello, Raffaele; Zarrella, Ilaria; Motta, Oriana

    2016-11-01

    The (13)C/(12)C carbon isotope ratio is a chemical parameter with many important applications in several scientific area and the technique of choice currently used for the δ(13)C determination is the isotope ratio mass spectrometry (IRMS). This latter is highly accurate (0.1‰) and sensitive (up to 0.01‰), but at the same time expensive and complex. The objective of this work was to assess the reliability of FTIR and NDIRS techniques for the measurement of carbon stable isotope ratio of food sample, in comparison to IRMS. IRMS, NDIRS and FTIR were used to analyze samples of food, such as oil, durum, cocoa, pasta and sugar, in order to determine the natural abundance isotopic ratio of carbon in a parallel way. The results were comparable, showing a close relationship among the three techniques. The main advantage in using FTIR and NDIRS is related to their cheapness and easy-to-operate in comparison to IRMS. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Application of electrochemical impedance spectroscopy: A phase behavior study of babassu biodiesel-based microemulsions.

    PubMed

    Pereira, Thulio C; Conceição, Carlos A F; Khan, Alamgir; Fernandes, Raquel M T; Ferreira, Maira S; Marques, Edmar P; Marques, Aldaléa L B

    2016-11-05

    Microemulsions are thermodynamically stable systems of two immiscible liquids, one aqueous and the other of organic nature, with a surfactant and/or co-surfactant adsorbed in the interface between the two phases. Biodiesel-based microemulsions, consisting of alkyl esters of fatty acids, open a new means of analysis for the application of electroanalytical techniques, and is advantageous as it eliminates the required pre-treatment of a sample. In this work, the phase behaviours of biodiesel-based microemulsions were investigated through the electrochemical impedance spectroscopy (EIS) technique. We observed thatan increase in the amount of biodiesel in the microemulsion formulation increases the resistance to charge transfer at the interface. Also, the electrical conductivity measurements revealed that a decrease or increase in electrical properties depends on the amount of biodiesel. EIS studies of the biodiesel-based microemulsion samples showed the presence of two capacitive arcs: one high-frequency and the other low-frequency. Thus, the formulation of microemulsions plays an important role in estimating the electrical properties through the electrochemical impedance spectroscopy technique. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Application of electrochemical impedance spectroscopy: A phase behavior study of babassu biodiesel-based microemulsions

    NASA Astrophysics Data System (ADS)

    Pereira, Thulio C.; Conceição, Carlos A. F.; Khan, Alamgir; Fernandes, Raquel M. T.; Ferreira, Maira S.; Marques, Edmar P.; Marques, Aldaléa L. B.

    2016-11-01

    Microemulsions are thermodynamically stable systems of two immiscible liquids, one aqueous and the other of organic nature, with a surfactant and/or co-surfactant adsorbed in the interface between the two phases. Biodiesel-based microemulsions, consisting of alkyl esters of fatty acids, open a new means of analysis for the application of electroanalytical techniques, and is advantageous as it eliminates the required pre-treatment of a sample. In this work, the phase behaviours of biodiesel-based microemulsions were investigated through the electrochemical impedance spectroscopy (EIS) technique. We observed thatan increase in the amount of biodiesel in the microemulsion formulation increases the resistance to charge transfer at the interface. Also, the electrical conductivity measurements revealed that a decrease or increase in electrical properties depends on the amount of biodiesel. EIS studies of the biodiesel-based microemulsion samples showed the presence of two capacitive arcs: one high-frequency and the other low-frequency. Thus, the formulation of microemulsions plays an important role in estimating the electrical properties through the electrochemical impedance spectroscopy technique.

  5. Experimental Aspects and Implementation of HPTLC

    NASA Astrophysics Data System (ADS)

    Patel, Rashmin B.; Patel, Mrunali R.; Batel, Bharat G.

    High-Performance Thin-Layer Chromatography (HPTLC) is a sophisticated instrumentation technique. It has been reported in many publications to provide excellent separation and qualitative and quantitative analysis of a wide range of compounds, such as herbal and botanical dietary supplements, nutraceuticals, traditional western medicines, traditional Chinese medicines, and Ayurvedic (Indian) medicines (Sharma 2008). Comparative studies have often found that HPTLC is superior to High-Performance Liquid Chromatography (HPLC) in terms of total cost and time required for analysis. HPTLC is an off-line process in which the various stages are carried out independently. Important features of HPTLC are the ability to analyze cruder samples containing multicomponents; application of large number of sample and a series of standards using the spray-on technique; choice of solvents for the HPTLC development is wide as the mobile phases are fully evaporated before the detection step; processing of standards and samples identically on the same plate, leading to better accuracy and precision of quantification; different and universal selective detection methods, and in situ spectra recording in sequence to obtain positive identification of fractions; storage of total sample on layer, without time constrains. In addition, it minimizes exposure risks and significantly reduces disposal problems of toxic organic effluents; thereby, reduce possibilities of environment pollution. In view of this, HPTLC-based methods could be considered as a good alternative as they are being explored as an important tool in routine analysis. This chapter provides detailed information regarding HPTLC-based analytical method development (Renger 1993; Renger 1998; Patel and Patel 2008; Patel et al. 2010).

  6. Characterization of Source Signatures of Fine Roadway Particles by Pyrolysis-GC-MS

    NASA Astrophysics Data System (ADS)

    van Bergen, S. K.; Holmén, B. A.

    2001-12-01

    Fine particulate matter, defined as particles with an aerodynamic diameter less than 2.5 μ m (PM2.5), is of growing concern due to its detrimental effects on human health and the environment. Roadway traffic generates a significant fraction of PM2.5 in urban areas. Since exposure to fine particles derived from mobile sources commonly occurs, understanding the physicochemical processes that contribute to the generation, transport and atmospheric reactivity of roadway PM is important. Factors that influence the properties of roadway PM include: the mass, number and size distribution of the particles as well as their chemical composition. These factors are partially determined by the sources of the roadway particles. The focus of this effort is to identify unique organic chemical profiles of known roadway sources of PM using a new rapid characterization technique. A pyrolysis GC-MS analytical method is being developed to uniquely characterize the sources of roadway PM2.5 such as brake dust, tire wear, and direct emissions from diesel and gasoline engines. The source profiles will be used in conjunction with measurements of the composition of ambient roadway PM to determine the importance of the various roadway sources. The advantages of this technique over conventional solvent extractions include: smaller (mg) sample mass requirements, short extraction times and minimal sample handing. Preliminary two-step pyrolysis results will be presented for PM samples from individual sources and an ambient roadway. Specific analytical issues that will be discussed include: modifications of commercial pyrolysis hardware to improve reproducibility; desorption versus pyrolysis; developing appropriate pyrolysis programs for heterogenous sample materials; and method detection limits.

  7. Immunoaffinity based methods are superior to kits for purification of prostate derived extracellular vesicles from plasma samples.

    PubMed

    Brett, Sabine I; Lucien, Fabrice; Guo, Charles; Williams, Karla C; Kim, Yohan; Durfee, Paul N; Brinker, C J; Chin, Joseph I; Yang, Jun; Leong, Hon S

    2017-05-01

    The ability to isolate extracellular vesicles (EVs) such as exosomes or microparticles is an important method that is currently not standardized. While commercially available kits offer purification of EVs from biofluids, such purified EV samples will also contain non-EV entities such as soluble protein and nucleic acids that could confound subsequent experimentation. Ideally, only EVs would be isolated and no soluble protein would be present in the final EV preparation. We compared commercially available EV isolation kits with immunoaffinity purification techniques and evaluated our final EV preparations using atomic force microscopy (AFM) and nanoscale flow cytometry (NFC). AFM is the only modality capable of detecting distinguishing soluble protein from EVs which is important for downstream proteomics approaches. NFC is the only technique capable of quantitating the proportion of target EVs to non-target EVs in the final EV preparation. To determine enrichment of prostate derived EVs relative to non-target MPs, anti-PSMA (Prostate Specific Membrane Antigen) antibodies were used in NFC. Antibody-based immunoaffinity purification generated the highest quality of prostate derived EV preparations due to the lack of protein and RNA present in the samples. All kits produced poor purity EV preparations that failed to deplete the sample of plasma protein. While attractive due to their ease of use, EV purification kits do not provide substantial improvements in isolation of EVs from biofluids such as plasma. Immunoaffinity approaches are more efficient and economical and will also eliminate a significant portion of plasma proteins which is necessary for downstream approaches. © 2017 Wiley Periodicals, Inc.

  8. Dynamic-focusing microscope objective for optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Murali, Supraja; Rolland, Jannick

    2007-01-01

    Optical Coherence Tomography (OCT) is a novel optical imaging technique that has assumed significant importance in bio-medical imaging in the last two decades because it is non-invasive and provides accurate, high resolution images of three dimensional cross-sections of body tissue, exceeding the capabilities of the current predominant imaging technique - ultrasound. In this paper, the application of high resolution OCT, known as optical coherence microscopy (OCM) is investigated for in vivo detection of abnormal skin pathology for the early diagnosis of cancer. A main challenge in OCM is maintaining invariant resolution throughout the sample. The technology presented is based on a dynamic focusing microscope imaging probe conceived for skin imaging and the detection of abnormalities in the epithelium. A novel method for dynamic focusing in the biological sample is presented using variable-focus lens technology to obtain three dimensional images with invariant resolution throughout the cross-section and depth of the sample is presented and discussed. A low coherence broadband source centered at near IR wavelengths is used to illuminate the sample. The design, analysis and predicted performance of the dynamic focusing microscope objective designed for dynamic three dimensional imaging at 5μm resolution for the chosen broadband spectrum is presented.

  9. Modulated Raman spectroscopy for enhanced identification of bladder tumor cells in urine samples.

    PubMed

    Canetta, Elisabetta; Mazilu, Michael; De Luca, Anna Chiara; Carruthers, Antonia E; Dholakia, Kishan; Neilson, Sam; Sargeant, Harry; Briscoe, Tina; Herrington, C Simon; Riches, Andrew C

    2011-03-01

    Standard Raman spectroscopy (SRS) is a noninvasive technique that is used in the biomedical field to discriminate between normal and cancer cells. However, the presence of a strong fluorescence background detracts from the use of SRS in real-time clinical applications. Recently, we have reported a novel modulated Raman spectroscopy (MRS) technique to extract the Raman spectra from the background. In this paper, we present the first application of MRS to the identification of human urothelial cells (SV-HUC-1) and bladder cancer cells (MGH) in urine samples. These results are compared to those obtained by SRS. Classification using the principal component analysis clearly shows that MRS allows discrimination between Raman spectra of SV-HUC-1 and MGH cells with high sensitivity (98%) and specificity (95%). MRS is also used to distinguish between SV-HUC-1 and MGH cells after exposure to urine for up to 6 h. We observe a marked change in the MRS of SV-HUC-1 and MGH cells with time in urine, indicating that the conditions of sample collection will be important for the application of this methodology to clinical urine samples.

  10. Investigation of solvent-free MALDI-TOFMS sample preparation methods for the analysis of organometallic and coordination compounds.

    PubMed

    Hughes, Laura; Wyatt, Mark F; Stein, Bridget K; Brenton, A Gareth

    2009-01-15

    An investigation of various solvent-free matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) sample preparation methods for the characterization of organometallic and coordination compounds is described. Such methods are desirable for insoluble materials, compounds that are only soluble in disadvantageous solvents, or complexes that dissociate in solution, all of which present a major "difficulty" to most mass spectrometry techniques. First-row transition metal acetylacetonate complexes, which have been characterized previously by solution preparation MALDI-TOFMS, were used to evaluate the various solvent-free procedures. These procedures comprise two distinct steps: the first being the efficient "solids mixing" (the mixing of sample and matrix), and the second being the effective transfer of the sample/matrix mixture to the MALDI target plate. This investigation shows that vortex mixing is the most efficient first step and that smearing using a microspatula is the most effective second step. In addition, the second step is shown to be much more critical than the first step in obtaining high-quality data. Case studies of truly insoluble materials highlight the importance of these techniques for the wider chemistry community.

  11. X-ray computed tomography imaging: A not-so-nondestructive technique

    NASA Astrophysics Data System (ADS)

    Sears, Derek W. G.; Sears, Hazel; Ebel, Denton S.; Wallace, Sean; Friedrich, Jon M.

    2016-04-01

    X-ray computed tomography has become a popular means for examining the interiors of meteorites and has been advocated for routine curation and for the examination of samples returned by missions. Here, we report the results of a blind test that indicate that CT imaging deposits a considerable radiation dose in a meteorite and seriously compromises its natural radiation record. Ten vials of the Bruderheim L6 chondrite were placed in CT imager and exposed to radiation levels typical for meteorite studies. Half were retained as controls. Their thermoluminescence (TL) properties were then measured in a blind test. Five of the samples had TL data unaltered from their original (~10 cps) while five had very strong signals (~20,000 cps). It was therefore very clear which samples had been in the CT scanner. For comparison, the natural TL signal from Antarctic meteorites is ~5000-50,000 cps. Using the methods developed for Antarctic meteorites, the apparent dose absorbed by the five test samples was calculated to be 83 ± 5 krad, comparable with the highest doses observed in Antarctic meteorites and freshly fallen meteorites. While these results do not preclude the use of CT scanners when scientifically justified, it should be remembered that the record of radiation exposure to ionizing radiations for the sample will be destroyed and that TL, or the related optically stimulated luminescence, are the primary modern techniques for radiation dosimetry. This is particularly important with irreplaceable samples, such as meteorite main masses, returned samples, and samples destined for archive.

  12. Comparison of polymerase chain reaction and Warthin-Starry techniques to detect Leptospira spp. in kidneys of slaughtered cattle.

    PubMed

    Azizi, Shahrzad; Kheirandish, Reza; Rahimi, Elham

    2014-11-12

    Leptospirosis is a worldwide zoonotic disease that is caused by Gram-negative spirochaetes, Leptospira species. Affected animals excrete the organism in the urine into the environment and act as a source of infection. Cattle are maintenance hosts for some serovars of leptospirosis and are important in the transmission of the infection to humans. At post mortem examination, affected cattle show white spots in their kidneys but these are not specific for leptospirosis. Sometimes it is necessary that leptospirosis be diagnosed in the carcass. Different direct methods, including polymerase chain reaction (PCR), Warthin-Starry silver stain (WS), immunofluorescence (IF) and immunohistochemistry (IHC) can be used in order to diagnose leptospirosis in the affected tissues, such as kidney. The main advantage of the WS technique is direct visualisation of the bacteria in the tissue samples. Silver staining is useful for retrospective studies on formalin-fixed and paraffin-embedded samples but little information is available on the sensitivity and specificity of the technique. The present study aimed to find a simple and inexpensive method that can be used in any laboratory and that also, if clinical samples are not available, can detect Leptospira in tissue samples post mortem. This study was performed on 19 paraffin-embedded kidneys of slaughtered cows that grossly had focal to multifocal white spots. Leptospirosis was confirmed in these samples with PCR based on the LipL32 gene. Out of 19 PCR positive kidneys, Leptospira was identified in 13 stained samples by WS. The kidneys revealed different grades of interstitial nephritis. No relationship was found between severity of lesions and presence of leptospires in the kidneys. The PCR results on the urine and blood were consistent with matching WS stained kidneys. Out of 13 kidneys that were positive with silver staining, 7 matching blood and 10 matching urine samples were confirmed positive for leptospirosis with PCR. In this study, the WS technique provided fewer positive results than PCR. This may be as a result of a low burden of Leptospira in the kidney, but the sensitivity of WS staining needs more investigation.

  13. Genotyping of Giardia duodenalis in vegetables cultivated with organic and chemical fertilizer from street markets and community vegetable gardens in a region of Southern Brazil.

    PubMed

    Rafael, Katyelle; Marchioro, Ariella A; Colli, Cristiane M; Tiyo, Bruna T; Evangelista, Fernanda F; Bezagio, Renata C; Falavigna-Guilherme, Ana L

    2017-12-01

    In order to investigate the occurrence of Giardia duodenalis and its genotypes in vegetables that are consumed raw, we analyzed samples cultivated with organic or chemical fertilizer, sold in street markets and from community vegetable gardens in an urban area located in Southern Brazil. We analyzed 130 samples of vegetables such as crisp lettuce, regular lettuce, kale, chicory and rocket, from street markets, and 130 from community gardens. From each sample, 50 g were washed in Tween 80 solution (1%) and the solution obtained was filtered through a cellulose acetate membrane. The retained material was used for DNA extraction with the commercial kit Purelink®. GDH gene was amplified by semi-nested PCR using the GDHeF, GDHiR and GDHiF primers. Positive samples were genotyped using the PCR-RFLP technique with the restriction enzyme NlaIV. We obtained 7.3% (19/260) positive samples for G. duodenalis, both from street markets (10/130) and from community gardens (9/130), including organic and non-organic products. The assemblage AI was predominant, but assemblages B and E were also found. The molecular technique revealed genotypes with zoonotic potential, evidencing the importance of investigating commercialized vegetables that are consumed raw and establishing a more rigid quality control.

  14. Finite element simulation of the T-shaped ECAP processing of round samples

    NASA Astrophysics Data System (ADS)

    Shaban Ghazani, Mehdi; Fardi-Ilkhchy, Ali; Binesh, Behzad

    2018-05-01

    Grain refinement is the only mechanism that increases the yield strength and toughness of the materials simultaneously. Severe plastic deformation is one of the promising methods to refine the microstructure of materials. Among different severe plastic deformation processes, the T-shaped equal channel angular pressing (T-ECAP) is a relatively new technique. In the present study, finite element analysis was conducted to evaluate the deformation behavior of metals during T-ECAP process. The study was focused mainly on flow characteristics, plastic strain distribution and its homogeneity, damage development, and pressing force which are among the most important factors governing the sound and successful processing of nanostructured materials by severe plastic deformation techniques. The results showed that plastic strain is localized in the bottom side of sample and uniform deformation cannot be possible using T-ECAP processing. Friction coefficient between sample and die channel wall has a little effect on strain distributions in mirror plane and transverse plane of deformed sample. Also, damage analysis showed that superficial cracks may be initiated from bottom side of sample and their propagation will be limited due to the compressive state of stress. It was demonstrated that the V shaped deformation zone are existed in T-ECAP process and the pressing load needed for execution of deformation process is increased with friction.

  15. Preparation and Characterization of Microencapsulated Phase Change Materials for Use in Building Applications.

    PubMed

    Giro-Paloma, Jessica; Al-Shannaq, Refat; Fernández, Ana Inés; Farid, Mohammed M

    2015-12-26

    A method for preparing and characterizing microencapsulated phase change materials (MPCM) was developed. A comparison with a commercial MPCM is also presented. Both MPCM contained paraffin wax as PCM with acrylic shell. The melting temperature of the PCM was around 21 °C, suitable for building applications. The M-2 (our laboratory made sample) and Micronal ® DS 5008 X (BASF) samples were characterized using SEM, DSC, nano-indentation technique, and Gas Chromatography/Mass spectrometry (GC-MS). Both samples presented a 6 μm average size and a spherical shape. Thermal energy storage (TES) capacities were 111.73 J·g -1 and 99.3 J·g -1 for M-2 and Micronal ® DS 5008 X, respectively. Mechanical characterization of the samples was performed by nano-indentation technique in order to determine the elastic modulus ( E ), load at maximum displacement ( P m ), and displacement at maximum load ( h m ), concluding that M-2 presented slightly better mechanical properties. Finally, an important parameter for considering use in buildings is the release of volatile organic compounds (VOC's). This characteristic was studied at 65 °C by CG-MS. Both samples showed VOC's emission after 10 min of heating, however peaks intensity of VOC's generated from M-2 microcapsules showed a lower concentration than Micronal ® DS 5008 X.

  16. Multidimensional High-Resolution Magic Angle Spinning and Solution-State NMR Characterization of 13C-labeled Plant Metabolites and Lignocellulose

    PubMed Central

    Mori, Tetsuya; Tsuboi, Yuuri; Ishida, Nobuhiro; Nishikubo, Nobuyuki; Demura, Taku; Kikuchi, Jun

    2015-01-01

    Lignocellulose, which includes mainly cellulose, hemicellulose, and lignin, is a potential resource for the production of chemicals and for other applications. For effective production of materials derived from biomass, it is important to characterize the metabolites and polymeric components of the biomass. Nuclear magnetic resonance (NMR) spectroscopy has been used to identify biomass components; however, the NMR spectra of metabolites and lignocellulose components are ambiguously assigned in many cases due to overlapping chemical shift peaks. Using our 13C-labeling technique in higher plants such as poplar samples, we demonstrated that overlapping peaks could be resolved by three-dimensional NMR experiments to more accurately assign chemical shifts compared with two-dimensional NMR measurements. Metabolites of the 13C-poplar were measured by high-resolution magic angle spinning NMR spectroscopy, which allows sample analysis without solvent extraction, while lignocellulose components of the 13C-poplar dissolved in dimethylsulfoxide/pyridine solvent were analyzed by solution-state NMR techniques. Using these methods, we were able to unambiguously assign chemical shifts of small and macromolecular components in 13C-poplar samples. Furthermore, using samples of less than 5 mg, we could differentiate between two kinds of genes that were overexpressed in poplar samples, which produced clearly modified plant cell wall components. PMID:26143886

  17. Two sampling techniques for game meat.

    PubMed

    van der Merwe, Maretha; Jooste, Piet J; Hoffman, Louw C; Calitz, Frikkie J

    2013-03-20

    A study was conducted to compare the excision sampling technique used by the export market and the sampling technique preferred by European countries, namely the biotrace cattle and swine test. The measuring unit for the excision sampling was grams (g) and square centimetres (cm2) for the swabbing technique. The two techniques were compared after a pilot test was conducted on spiked approved beef carcasses (n = 12) that statistically proved the two measuring units correlated. The two sampling techniques were conducted on the same game carcasses (n = 13) and analyses performed for aerobic plate count (APC), Escherichia coli and Staphylococcus aureus, for both techniques. A more representative result was obtained by swabbing and no damage was caused to the carcass. Conversely, the excision technique yielded fewer organisms and caused minor damage to the carcass. The recovery ratio from the sampling technique improved 5.4 times for APC, 108.0 times for E. coli and 3.4 times for S. aureus over the results obtained from the excision technique. It was concluded that the sampling methods of excision and swabbing can be used to obtain bacterial profiles from both export and local carcasses and could be used to indicate whether game carcasses intended for the local market are possibly on par with game carcasses intended for the export market and therefore safe for human consumption.

  18. Evaluation of inflammatory processes by FTIR spectroscopy.

    PubMed

    Rodrigues, Laís Morandini; Carvalho, Luís Felipe das Chagas E Silva; Bonnier, Franck; Anbinder, Ana Lia; Martinho, Herculano da Silva; Almeida, Janete Dias

    2018-04-01

    Fourier transform infrared (FTIR) spectroscopy is a powerful diagnosis technique and has been used to identify patterns of molecular changes based on vibration modes. The objective of this study was to evaluate inflammatory fibrous hyperplasia (IFH) lesions and oral normal mucosa (NM) initially with histopathological exam and then using micro-FTIR spectroscopy to analyse the samples. Eleven IFH and 11 NM samples were analysed at five different points to cover the largest area possible by the micro-FTIR technique. Bands were observed between 970 and 1743 cm -1 which corresponded to different structural components like collagen, lipids, fatty acids, proteins and amino acids. Spectral bands were more intense mostly for IFH lesions, including collagen bands, which are an important component of inflammatory fibrous hyperplasia. This study demonstrated that differentiation in the inflammatory tissue was observed in FTIR spectral differences, in terms of biochemical composition.

  19. Comparison of measured and calculated dynamic loads for the Mod-2 2.5 mW wind turbine system

    NASA Technical Reports Server (NTRS)

    Zimmerman, D. K.; Shipley, S. A.; Miller, R. D.

    1995-01-01

    The Boeing Company, under contract to the Electric Power Research Institute (EPRI), has completed a test program on the Mod-2 wind turbines at Goodnoe Hills, Washington. The objectives were to update fatigue load spectra, discern site and machine differences, measure vortex generator effects, and to evaluate rotational sampling techniques. This paper shows the test setup and loads instrumentation, loads data comparisons and test/analysis correlations. Test data are correlated with DYLOSAT predictions using both the NASA interim turbulence model and rotationally sampled winds as inputs. The latter is demonstrated to have the potential to improve the test/analysis correlations. The paper concludes with an assessment of the importance of vortex generators, site dependence, and machine differences on fatigue loads. The adequacy of prediction techniques used are evaluated and recommendations are made for improvements to the methodology.

  20. Fast Measurement of Soluble Solid Content in Mango Based on Visible and Infrared Spectroscopy Technique

    NASA Astrophysics Data System (ADS)

    Yu, Jiajia; He, Yong

    Mango is a kind of popular tropical fruit, and the soluble solid content is an important in this study visible and short-wave near-infrared spectroscopy (VIS/SWNIR) technique was applied. For sake of investigating the feasibility of using VIS/SWNIR spectroscopy to measure the soluble solid content in mango, and validating the performance of selected sensitive bands, for the calibration set was formed by 135 mango samples, while the remaining 45 mango samples for the prediction set. The combination of partial least squares and backpropagation artificial neural networks (PLS-BP) was used to calculate the prediction model based on raw spectrum data. Based on PLS-BP, the determination coefficient for prediction (Rp) was 0.757 and root mean square and the process is simple and easy to operate. Compared with the Partial least squares (PLS) result, the performance of PLS-BP is better.

  1. Fine refinement of solid state structure of racemic form of phospho-tyrosine employing NMR Crystallography approach.

    PubMed

    Paluch, Piotr; Pawlak, Tomasz; Oszajca, Marcin; Lasocha, Wieslaw; Potrzebowski, Marek J

    2015-02-01

    We present step by step facets important in NMR Crystallography strategy employing O-phospho-dl-tyrosine as model sample. The significance of three major techniques being components of this approach: solid state NMR (SS NMR), X-ray diffraction of powdered sample (PXRD) and theoretical calculations (Gauge Invariant Projector Augmented Wave; GIPAW) is discussed. Each experimental technique provides different set of structural constraints. From the PXRD measurement the size of the unit cell, space group and roughly refined molecular structure are established. SS NMR provides information about content of crystallographic asymmetric unit, local geometry, molecular motion in the crystal lattice and hydrogen bonding pattern. GIPAW calculations are employed for validation of quality of elucidation and fine refinement of structure. Crystal and molecular structure of O-phospho-dl-tyrosine solved by NMR Crystallography is deposited at Cambridge Crystallographic Data Center under number CCDC 1005924. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Overview of Brain Microdialysis

    PubMed Central

    Chefer, Vladimir I.; Thompson, Alexis C.; Zapata, Agustin; Shippenberg, Toni S.

    2010-01-01

    The technique of microdialysis enables sampling and collecting of small-molecular-weight substances from the interstitial space. It is a widely used method in neuroscience and is one of the few techniques available that permits quantification of neurotransmitters, peptides, and hormones in the behaving animal. More recently, it has been used in tissue preparations for quantification of neurotransmitter release. This unit provides a brief review of the history of microdialysis and its general application in the neurosciences. The authors review the theoretical principles underlying the microdialysis process, methods available for estimating extracellular concentration from dialysis samples (i.e., relative recovery), the various factors that affect the estimate of in vivo relative recovery, and the importance of determining in vivo relative recovery to data interpretation. Several areas of special note, including impact of tissue trauma on the interpretation of microdialysis results, are discussed. Step-by-step instructions for the planning and execution of conventional and quantitative microdialysis experiments are provided. PMID:19340812

  3. The Mediating Effect of Self-Control on Parenting and Delinquency: A Gendered Approach With a Multinational Sample.

    PubMed

    Muftić, Lisa R; Updegrove, Alexander H

    2017-08-01

    This study aims to clarify the relationships between parenting techniques, low self-control, and juvenile delinquency in Gottfredson and Hirschi's general theory of crime while controlling for alternative explanations of delinquency. We relied on a sample of 35,511 adolescent students from 31 countries from the International Self-Report Delinquency 2 Study. Results indicate that parenting exhibits a direct effect on adolescents' violence perpetration and property offending, and that while self-control weakens the strength of this relationship, it fails to fully mediate it. Males reported lower levels of self-control, exposure to poorer parenting techniques, and higher rates of violence perpetration and property offending. The relationship between parenting, self-control, and juvenile delinquency was similar for females and males. These results provide evidence that parenting has important implications for adolescents' involvement in delinquency above and beyond its influence on their level of self-control.

  4. Investigations of calcium spectral lines in laser-induced breakdown spectroscopy

    NASA Astrophysics Data System (ADS)

    Ching, Sim Yit; Tariq, Usman; Haider, Zuhaib; Tufail, Kashif; Sabri, Salwanie; Imran, Muhammad; Ali, Jalil

    2017-03-01

    Laser-induced breakdown spectroscopy (LIBS) is a direct and versatile analytical technique that performs the elemental composition analysis based on optical emission produced by laser induced-plasma, with a little or no sample preparation. The performance of the LIBS technique relies on the choice of experimental conditions which must be thoroughly explored and optimized for each application. The main parameters affecting the LIBS performance are the laser energy, laser wavelength, pulse duration, gate delay, geometrical set-up of the focusing and collecting optics. In LIBS quantitative analysis, the gate delay and laser energy are very important parameters that have pronounced impact on the accuracy of the elemental composition information of the materials. The determination of calcium elements in the pelletized samples was investigated and served for the purpose of optimizing the gate delay and laser energy by studying and analyzing the results from emission intensities collected and signal to background ratio (S/B) for the specified wavelengths.

  5. A comparison of sample preparation strategies for biological tissues and subsequent trace element analysis using LA-ICP-MS.

    PubMed

    Bonta, Maximilian; Török, Szilvia; Hegedus, Balazs; Döme, Balazs; Limbeck, Andreas

    2017-03-01

    Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) is one of the most commonly applied methods for lateral trace element distribution analysis in medical studies. Many improvements of the technique regarding quantification and achievable lateral resolution have been achieved in the last years. Nevertheless, sample preparation is also of major importance and the optimal sample preparation strategy still has not been defined. While conventional histology knows a number of sample pre-treatment strategies, little is known about the effect of these approaches on the lateral distributions of elements and/or their quantities in tissues. The technique of formalin fixation and paraffin embedding (FFPE) has emerged as the gold standard in tissue preparation. However, the potential use for elemental distribution studies is questionable due to a large number of sample preparation steps. In this work, LA-ICP-MS was used to examine the applicability of the FFPE sample preparation approach for elemental distribution studies. Qualitative elemental distributions as well as quantitative concentrations in cryo-cut tissues as well as FFPE samples were compared. Results showed that some metals (especially Na and K) are severely affected by the FFPE process, whereas others (e.g., Mn, Ni) are less influenced. Based on these results, a general recommendation can be given: FFPE samples are completely unsuitable for the analysis of alkaline metals. When analyzing transition metals, FFPE samples can give comparable results to snap-frozen tissues. Graphical abstract Sample preparation strategies for biological tissues are compared with regard to the elemental distributions and average trace element concentrations.

  6. Comparative testing of nondestructive examination techniques for concrete structures

    NASA Astrophysics Data System (ADS)

    Clayton, Dwight A.; Smith, Cyrus M.

    2014-03-01

    A multitude of concrete-based structures are typically part of a light water reactor (LWR) plant to provide foundation, support, shielding, and containment functions. Concrete has been used in the construction of nuclear power plants (NPPs) because of three primary properties, its inexpensiveness, its structural strength, and its ability to shield radiation. Examples of concrete structures important to the safety of LWR plants include containment building, spent fuel pool, and cooling towers. Comparative testing of the various NDE concrete measurement techniques requires concrete samples with known material properties, voids, internal microstructure flaws, and reinforcement locations. These samples can be artificially created under laboratory conditions where the various properties can be controlled. Other than NPPs, there are not many applications where critical concrete structures are as thick and reinforced. Therefore, there are not many industries other than the nuclear power plant or power plant industry that are interested in performing NDE on thick and reinforced concrete structures. This leads to the lack of readily available samples of thick and heavily reinforced concrete for performing NDE evaluations, research, and training. The industry that typically performs the most NDE on concrete structures is the bridge and roadway industry. While bridge and roadway structures are thinner and less reinforced, they have a good base of NDE research to support their field NDE programs to detect, identify, and repair concrete failures. This paper will summarize the initial comparative testing of two concrete samples with an emphasis on how these techniques could perform on NPP concrete structures.

  7. Odor Sampling: Techniques and Strategies for the Estimation of Odor Emission Rates from Different Source Types

    PubMed Central

    Capelli, Laura; Sironi, Selena; Rosso, Renato Del

    2013-01-01

    Sampling is one of the main issues pertaining to odor characterization and measurement. The aim of sampling is to obtain representative information on the typical characteristics of an odor source by means of the collection of a suitable volume fraction of the effluent. The most important information about an emission source for odor impact assessment is the so-called Odor Emission Rate (OER), which represents the quantity of odor emitted per unit of time, and is expressed in odor units per second (ou·s−1). This paper reviews the different odor sampling strategies adopted depending on source type. The review includes an overview of odor sampling regulations and a detailed discussion of the equipment to be used as well as the mathematical considerations to be applied to obtain the OER in relation to the sampled source typology. PMID:23322098

  8. Laser-induced breakdown spectroscopy for detection of heavy metals in environmental samples

    NASA Astrophysics Data System (ADS)

    Wisbrun, Richard W.; Schechter, Israel; Niessner, Reinhard; Schroeder, Hartmut

    1993-03-01

    The application of LIBS technology as a sensor for heavy metals in solid environmental samples has been studied. This specific application introduces some new problems in the LIBS analysis. Some of them are related to the particular distribution of contaminants in the grained samples. Other problems are related to mechanical properties of the samples and to general matrix effects, like the water and organic fibers content of the sample. An attempt has been made to optimize the experimental set-up for the various involved parameters. The understanding of these factors has enabled the adjustment of the technique to the substrates of interest. The special importance of the grain size and of the laser-induced aerosol production is pointed out. Calibration plots for the analysis of heavy metals in diverse sand and soil samples have been carried out. The detection limits are shown to be usually below the recent regulation restricted concentrations.

  9. Odor sampling: techniques and strategies for the estimation of odor emission rates from different source types.

    PubMed

    Capelli, Laura; Sironi, Selena; Del Rosso, Renato

    2013-01-15

    Sampling is one of the main issues pertaining to odor characterization and measurement. The aim of sampling is to obtain representative information on the typical characteristics of an odor source by means of the collection of a suitable volume fraction of the effluent. The most important information about an emission source for odor impact assessment is the so-called Odor Emission Rate (OER), which represents the quantity of odor emitted per unit of time, and is expressed in odor units per second (ou∙s-1). This paper reviews the different odor sampling strategies adopted depending on source type. The review includes an overview of odor sampling regulations and a detailed discussion of the equipment to be used as well as the mathematical considerations to be applied to obtain the OER in relation to the sampled source typology.

  10. Size effects on electrical properties of chemically grown zinc oxide nanoparticles

    NASA Astrophysics Data System (ADS)

    Rathod, K. N.; Joshi, Zalak; Dhruv, Davit; Gadani, Keval; Boricha, Hetal; Joshi, A. D.; Solanki, P. S.; Shah, N. A.

    2018-03-01

    In the present article, we study ZnO nanoparticles grown by cost effective sol–gel technique for various electrical properties. Structural studies performed by x-ray diffraction (XRD) revealed hexagonal unit cell phase with no observed impurities. Transmission electron microscopy (TEM) and particle size analyzer showed increased average particle size due to agglomeration effect with higher sintering. Dielectric constant (ε‧) decreases with increase in frequency because of the disability of dipoles to follow higher electric field. With higher sintering, dielectric constant reduced owing to the important role of increased formation of oxygen vacancy defects. Universal dielectric response (UDR) was verified by straight line fitting of log (fε‧) versus log (f) plots. All samples exhibit UDR behavior and with higher sintering more contribution from crystal cores. Impedance studies suggest an important role of boundary density while Cole–Cole (Z″ versus Z‧) plots have been studied for the relaxation behavior of the samples. Average normalized change (ANC) in impedance has been studied for all the samples wherein boundaries play an important role. Frequency dependent electrical conductivity has been understood on the basis of Jonscher’s universal power law. Jonscher’s law fits suggest that conduction of charge carrier is possible in the context of correlated barrier hopping (CBH) mechanism for lower temperature sintered sample while for higher temperature sintered ZnO samples, Maxwell–Wagner (M–W) relaxation process has been determined.

  11. The application of novel nano-thermal and imaging techniques for monitoring drug microstructure and distribution within PLGA microspheres.

    PubMed

    Yang, Fan; Chen, De; Guo, Zhe-Fei; Zhang, Yong-Ming; Liu, Yi; Askin, Sean; Craig, Duncan Q M; Zhao, Min

    2017-04-30

    Poly (d,l-lactic-co-glycolic) acid (PLGA) based microspheres have been extensively used as controlled drug release systems. However, the burst effect has been a persistent issue associated with such systems, especially for those prepared by the double emulsion technique. An effective approach to preventing the burst effect and achieving a more ideal drug release profile is to improve the drug distribution within the polymeric matrix. Therefore, it is of great importance to establish a rapid and robust tool for screening and optimizing the drug distribution during pre-formulation. Transition Temperature Microscopy (TTM), a novel nano-thermal and imaging technique, is an extension of nano-thermal analysis (nano-TA) whereby a transition temperature is detected at a localized region of a sample and then designated a color based on a particular temperature/color palette, finally resulting in a coded map based on transition temperatures detected by carrying out a series of nanoTA measurements across the surface of the sample. In this study, we investigate the feasibility of applying the aforementioned technique combined with other thermal, imaging and structural techniques for monitoring the drug microstructure and spatial distribution within bovine serum albumin (BSA) loaded and nimodipine loaded PLGA microspheres, with a view to better predicting the in vitro drug release performance. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating

    PubMed Central

    Regalin, Alexandre; Bhering, Claudia Lopes Brilhante; Alessandretti, Rodrigo; Spazzin, Aloisio Oro

    2015-01-01

    PURPOSE The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading. MATERIALS AND METHODS Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A - torque with 32 Ncm (control); B - torque with 32 Ncm holding the torque meter for 20 seconds; C - torque with 32 Ncm and retorque after 10 minutes; D - torque (32 Ncm) holding the torque meter for 20 seconds and retorque after 10 minutes as initially. Samples were divided into subgroups according to the screw used: conventional titanium screw or diamond like carbon-coated (DLC) screw. Metallic crowns were fabricated for each abutment. Samples were submitted to cyclic loading at 106 cycles and 130 N of force. Data were analyzed by two-way ANOVA and Tukey's test (5%). RESULTS The tightening technique did not show significant influence on the loosening torque of screws (P=.509). Conventional titanium screws showed significant higher loosening torque values than DLC (P=.000). CONCLUSION The use of conventional titanium screw is more important than the tightening techniques employed in this study to provide long-term stability to Universal Abutment screws. PMID:26576253

  13. Biomedical applications of laser-induced breakdown spectroscopy (LIBS)

    NASA Astrophysics Data System (ADS)

    Unnikrishnan, V. K.; Nayak, Rajesh; Bhat, Sujatha; Mathew, Stanley; Kartha, V. B.; Santhosh, C.

    2015-03-01

    LIBS has been proven to be a robust elemental analysis tool attracting interest because of the wide applications. LIBS can be used for analysis of any type of samples i.e. environmental/physiological, regardless of its state of matter. Conventional spectroscopy techniques are good in analytical performance, but their sample preparation method is mostly destructive and time consuming. Also, almost all these methods are incapable of analysing multi elements simaltaneously. On the other hand, LIBS has many potential advantages such as simplicity in the experimental setup, less sample preparation, less destructive analysis of sample etc. In this paper, we report some of the biomedical applications of LIBS. From the experiments carried out on clinical samples (calcified tissues or teeth and gall stones) for trace elemental mapping and detection, it was found that LIBS is a robust tool for such applications. It is seen that the presence and relative concentrations of major elements (calcium, phosphorus and magnesium) in human calcified tissue (tooth) can be easily determined using LIBS technique. The importance of this study comes in anthropology where tooth and bone are main samples from which reliable data can be easily retrieved. Similarly, elemental composition of bile juice and gall stone collected from the same subject using LIBS was found to be similar. The results show interesting prospects for LIBS to study cholelithiasis (the presence of stones in the gall bladder, is a common disease of the gastrointestinal tract) better.

  14. Reduction of measurement errors in OCT scanning

    NASA Astrophysics Data System (ADS)

    Morel, E. N.; Tabla, P. M.; Sallese, M.; Torga, J. R.

    2018-03-01

    Optical coherence tomography (OCT) is a non-destructive optical technique, which uses a light source with a wide band width that focuses on a point in the sample to determine the distance (strictly, the optical path difference, OPD) between this point and a reference surface. The point can be superficial or at an interior interface of the sample (transparent or semitransparent), allowing topographies and / or tomographies in different materials. The Michelson interferometer is the traditional experimental scheme for this technique, in which a beam of light is divided into two arms, one the reference and the other the sample. The overlap of reflected light in the sample and in the reference generates an interference signal that gives us information about the OPD between arms. In this work, we work on the experimental configuration in which the reference signal and the reflected signal in the sample travel on the same arm, improving the quality of the interference signal. Among the most important aspects of this improvement we can mention that the noise and errors produced by the relative reference-sample movement and by the dispersion of the refractive index are considerably reduced. It is thus possible to obtain 3D images of surfaces with a spatial resolution in the order of microns. Results obtained on the topography of metallic surfaces, glass and inks printed on paper are presented.

  15. Evaluation of the 3D spatial distribution of the Calcium/Phosphorus ratio in bone using computed-tomography dual-energy analysis.

    PubMed

    Hadjipanteli, A; Kourkoumelis, N; Fromme, P; Huang, J; Speller, R D

    2016-01-01

    The Calcium/Phosphorus (Ca/P) ratio was shown to vary between healthy bones and bones with osteoporotic symptoms. The relation of the Ca/P ratio to bone quality remains under investigation. To study this relation and determine if the ratio can be used to predict bone fractures, a non-invasive 3D imaging technique is required. The first aim of this study was to test the effectiveness of a computed-tomography dual-energy analysis (CT-DEA) technique developed to assess the Ca/P ratio in bone apatite (collagen-free bone) in identifying differences between healthy and inflammation-mediated osteoporotic (IMO) bones. The second aim was to extend the above technique for its application to a more complex structure, intact bone, that could potentially lead to clinical use. For the first aim, healthy and IMO rabbit cortical bone apatite samples were assessed. For the second aim, some changes were made to the technique, which was applied to healthy and IMO intact bone samples. Statistically significant differences between healthy and IMO bone apatite were found for the bulk Ca/P ratio, low Ca/P ratio proportion and interconnected low Ca/P ratio proportion. For the intact bone samples, the bulk Ca/P ratio was found to be significantly different between healthy and IMO. Results show that the CT-DEA technique can be used to identify differences in the Ca/P ratio between healthy and osteoporotic, in both bone apatite and intact bone. With quantitative imaging becoming an increasingly important advancement in medical imaging, CT-DEA for bone decomposition could potentially have several applications. Copyright © 2015. Published by Elsevier Ltd.

  16. Spectral Mining for Discriminating Blood Origins in the Presence of Substrate Interference via Attenuated Total Reflection Fourier Transform Infrared Spectroscopy: Postmortem or Antemortem Blood?

    PubMed

    Takamura, Ayari; Watanabe, Ken; Akutsu, Tomoko; Ikegaya, Hiroshi; Ozawa, Takeaki

    2017-09-19

    Often in criminal investigations, discrimination of types of body fluid evidence is crucially important to ascertain how a crime was committed. Compared to current methods using biochemical techniques, vibrational spectroscopic approaches can provide versatile applicability to identify various body fluid types without sample invasion. However, their applicability is limited to pure body fluid samples because important signals from body fluids incorporated in a substrate are affected strongly by interference from substrate signals. Herein, we describe a novel approach to recover body fluid signals that are embedded in strong substrate interferences using attenuated total reflection Fourier transform infrared (ATR FT-IR) spectroscopy and an innovative multivariate spectral processing. This technique supported detection of covert features of body fluid signals, and then identified origins of body fluid stains on substrates. We discriminated between ATR FT-IR spectra of postmortem blood (PB) and those of antemortem blood (AB) by creating a multivariate statistics model. From ATR FT-IR spectra of PB and AB stains on interfering substrates (polyester, cotton, and denim), blood-originated signals were extracted by a weighted linear regression approach we developed originally using principal components of both blood and substrate spectra. The blood-originated signals were finally classified by the discriminant model, demonstrating high discriminant accuracy. The present method can identify body fluid evidence independently of the substrate type, which is expected to promote the application of vibrational spectroscopic techniques in forensic body fluid analysis.

  17. A comparison of honey bee-collected pollen from working agricultural lands using light microscopy and ITS metabarcoding

    USGS Publications Warehouse

    Smart, Matthew; Cornman, Robert S.; Iwanowicz, Deborah; McDermott-Kubeczko, Margaret; Pettis, Jeff S; Spivak, Marla S; Otto, Clint R.

    2017-01-01

    Taxonomic identification of pollen has historically been accomplished via light microscopy but requires specialized knowledge and reference collections, particularly when identification to lower taxonomic levels is necessary. Recently, next-generation sequencing technology has been used as a cost-effective alternative for identifying bee-collected pollen; however, this novel approach has not been tested on a spatially or temporally robust number of pollen samples. Here, we compare pollen identification results derived from light microscopy and DNA sequencing techniques with samples collected from honey bee colonies embedded within a gradient of intensive agricultural landscapes in the Northern Great Plains throughout the 2010–2011 growing seasons. We demonstrate that at all taxonomic levels, DNA sequencing was able to discern a greater number of taxa, and was particularly useful for the identification of infrequently detected species. Importantly, substantial phenological overlap did occur for commonly detected taxa using either technique, suggesting that DNA sequencing is an appropriate, and enhancing, substitutive technique for accurately capturing the breadth of bee-collected species of pollen present across agricultural landscapes. We also show that honey bees located in high and low intensity agricultural settings forage on dissimilar plants, though with overlap of the most abundantly collected pollen taxa. We highlight practical applications of utilizing sequencing technology, including addressing ecological issues surrounding land use, climate change, importance of taxa relative to abundance, and evaluating the impact of conservation program habitat enhancement efforts.

  18. 1H MAS NMR (magic-angle spinning nuclear magnetic resonance) techniques for the quantitative determination of hydrogen types in solid catalysts and supports.

    PubMed

    Kennedy, Gordon J; Afeworki, Mobae; Calabro, David C; Chase, Clarence E; Smiley, Randolph J

    2004-06-01

    Distinct hydrogen species are present in important inorganic solids such as zeolites, silicoaluminophosphates (SAPOs), mesoporous materials, amorphous silicas, and aluminas. These H species include hydrogens associated with acidic sites such as Al(OH)Si, non-framework aluminum sites, silanols, and surface functionalities. Direct and quantitative methodology to identify, measure, and monitor these hydrogen species are key to monitoring catalyst activity, optimizing synthesis conditions, tracking post-synthesis structural modifications, and in the preparation of novel catalytic materials. Many workers have developed several techniques to address these issues, including 1H MAS NMR (magic-angle spinning nuclear magnetic resonance). 1H MAS NMR offers many potential advantages over other techniques, but care is needed in recognizing experimental limitations and developing sample handling and NMR methodology to obtain quantitatively reliable data. A simplified approach is described that permits vacuum dehydration of multiple samples simultaneously and directly in the MAS rotor without the need for epoxy, flame sealing, or extensive glovebox use. We have found that careful optimization of important NMR conditions, such as magnetic field homogeneity and magic angle setting are necessary to acquire quantitative, high-resolution spectra that accurately measure the concentrations of the different hydrogen species present. Details of this 1H MAS NMR methodology with representative applications to zeolites, SAPOs, M41S, and silicas as a function of synthesis conditions and post-synthesis treatments (i.e., steaming, thermal dehydroxylation, and functionalization) are presented.

  19. An extended laser flash technique for thermal diffusivity measurement of high-temperature materials

    NASA Technical Reports Server (NTRS)

    Shen, F.; Khodadadi, J. M.

    1993-01-01

    Knowledge of thermal diffusivity data for high-temperature materials (solids and liquids) is very important in analyzing a number of processes, among them solidification, crystal growth, and welding. However, reliable thermal diffusivity versus temperature data, particularly those for high-temperature liquids, are still far from complete. The main measurement difficulties are due to the presence of convection and the requirement for a container. Fortunately, the availability of levitation techniques has made it possible to solve the containment problem. Based on the feasibility of the levitation technology, a new laser flash technique which is applicable to both levitated liquid and solid samples is being developed. At this point, the analysis for solid samples is near completion and highlights of the technique are presented here. The levitated solid sample which is assumed to be a sphere is subjected to a very short burst of high power radiant energy. The temperature of the irradiated surface area is elevated and a transient heat transfer process takes place within the sample. This containerless process is a two-dimensional unsteady heat conduction problem. Due to the nonlinearity of the radiative plus convective boundary condition, an analytic solution cannot be obtained. Two options are available at this point. Firstly, the radiation boundary condition can be linearized, which then accommodates a closed-form analytic solution. Comparison of the analytic curves for the temperature rise at different points to the experimentally-measured values will then provide the thermal diffusivity values. Secondly, one may set up an inverse conduction problem whereby experimentally obtained surface temperature history is used as the boundary conditions. The thermal diffusivity can then be elevated by minimizing the difference between the real heat flux boundary condition (radiation plus convection) and the measurements. Status of an experimental study directed at measuring the thermal diffusivity of high-temperature solid samples of pure Nickel and Inconel 718 superalloys are presented. Preliminary measurements showing surface temperature histories are discussed.

  20. Methodological issues in microdialysis sampling for pharmacokinetic studies.

    PubMed

    de Lange, E C; de Boer, A G; Breimer, D D

    2000-12-15

    Microdialysis is an in vivo technique that permits monitoring of local concentrations of drugs and metabolites at specific sites in the body. Microdialysis has several characteristics, which makes it an attractive tool for pharmacokinetic research. About a decade ago the microdialysis technique entered the field of pharmacokinetic research, in the brain, and later also in peripheral tissues and blood. Within this period much has been learned on the proper use of this technique. Today, it has outgrown its child diseases and its potentials and limitations have become more or less well defined. As microdialysis is a delicate technique for which experimental factors appear to be critical with respect to the validity of the experimental outcomes, several factors should be considered. These include the probe; the perfusion solution; post-surgery interval in relation to surgical trauma, tissue integrity and repeated experiments; the analysis of microdialysate samples; and the quantification of microdialysate data. Provided that experimental conditions are optimized to give valid and quantitative results, microdialysis can provide numerous data points from a relatively small number of individual animals to determine detailed pharmacokinetic information. An example of one of the added values of this technique compared with other in vivo pharmacokinetic techniques, is that microdialysis reflects free concentrations in tissues and plasma. This gives the opportunity to assess information on drug transport equilibration across membranes such as the blood-brain barrier, which already has provided new insights. With the progress of analytical methodology, especially with respect to low volume/low concentration measurements and simultaneous measurement of multiple compounds, the applications and importance of the microdialysis technique in pharmacokinetic research will continue to increase.

  1. 3D imaging of cells and tissues by focused ion beam/scanning electron microscopy (FIB/SEM).

    PubMed

    Drobne, Damjana

    2013-01-01

    Integration of a scanning electron microscope (SEM) and focused ion beam (FIB) technology into a single FIB/SEM system permits use of the FIB as a nano-scalpel to reveal site-specific subsurface microstructures which can be examined in great detail by SEM. The FIB/SEM technology is widely used in the semiconductor industry and material sciences, and recently its use in the life sciences has been initiated. Samples for FIB/SEM investigation can be either embedded in a plastic matrix, the traditional means of preparation of transmission electron microscopy (TEM) specimens, or simply dried as in samples prepared for SEM imaging. Currently, FIB/SEM is used in the life sciences for (a) preparation by the lift-out technique of lamella for TEM analysis, (b) tomography of samples embedded in a matrix, and (c) in situ site-specific FIB milling and SEM imaging using a wide range of magnifications. Site-specific milling and imaging has attracted wide interest as a technique in structural research of single eukaryotic and prokaryotic cells, small animals, and different animal tissue, but it still remains to be explored more thoroughly. In the past, preparation of samples for site-specific milling and imaging by FIB/SEM has typically adopted the embedding techniques used for TEM samples, and which have been very well described in the literature. Sample preparation protocols for the use of dried samples in FIB/SEM have been less well investigated. The aim of this chapter is to encourage application of FIB/SEM on dried biological samples. A detailed description of conventional dried sample preparation and FIB/SEM investigation of dried biological samples is presented. The important steps are described and illustrated, and direct comparison between embedded and dried samples of same tissues is provided. The ability to discover links between gross morphology of the tissue or organ, surface characteristics of any selected region, and intracellular structural details on the nanometer scale is an appealing application of electron microscopy in the life sciences and merits further exploration.

  2. Microfluidic filtration and extraction of pathogens from food samples by hydrodynamic focusing and inertial lateral migration.

    PubMed

    Clime, Liviu; Hoa, Xuyen D; Corneau, Nathalie; Morton, Keith J; Luebbert, Christian; Mounier, Maxence; Brassard, Daniel; Geissler, Matthias; Bidawid, Sabah; Farber, Jeff; Veres, Teodor

    2015-02-01

    Detecting pathogenic bacteria in food or other biological samples with lab-on-a-chip (LOC) devices requires several sample preparation steps prior to analysis which commonly involves cleaning complex sample matrices of large debris. This often underestimated step is important to prevent these larger particles from clogging devices and to preserve initial concentrations when LOC techniques are used to concentrate or isolate smaller target microorganisms for downstream analysis. In this context, we developed a novel microfluidic system for membrane-free cleaning of biological samples from debris particles by combining hydrodynamic focusing and inertial lateral migration effects. The microfluidic device is fabricated using thermoplastic elastomers being compatible with thermoforming fabrication techniques leading to low-cost single-use devices. Microfluidic chip design and pumping protocols are optimized by investigating diffusive losses numerically with coupled Navier-Stokes and convective-diffusion theoretical models. Stability of inertial lateral migration and separation of debris is assessed through fluorescence microscopy measurements with labelled particles serving as a model system. Efficiency of debris cleaning is experimentally investigated by monitoring microchip outlets with in situ optical turbidity sensors, while retention of targeted pathogens (i.e., Listeria monocytogenes) within the sample stream is assessed through bacterial culture techniques. Optimized pumping protocols can remove up to 50 % of debris from ground beef samples while percentage for preserved microorganisms can account for 95 % in relatively clean samples. However, comparison between inoculated turbid and clean samples (i.e., with and without ground beef debris) indicate some degree of interference between debris inertial lateral migration and hydrodynamic focusing of small microorganisms. Although this interference can lead to significant decrease in chip performance through loss of target bacteria, it remains possible to reach 70 % for sample recovery and more than 50 % for debris removal even in the most turbid samples tested. Due to the relatively simple design, the robustness of the inertial migration effect itself, the high operational flow rates and fabrication methods that leverage low-cost materials, the proposed device can have an impact on a wide range of applications where high-throughput separation of particles and biological species is of interest.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walters, William; Hyde, Embriette R.; Berg-Lyons, Donna

    ABSTRACT Designing primers for PCR-based taxonomic surveys that amplify a broad range of phylotypes in varied community samples is a difficult challenge, and the comparability of data sets amplified with varied primers requires attention. Here, we examined the performance of modified 16S rRNA gene and internal transcribed spacer (ITS) primers for archaea/bacteria and fungi, respectively, with nonaquatic samples. We moved primer bar codes to the 5′ end, allowing for a range of different 3′ primer pairings, such as the 515f/926r primer pair, which amplifies variable regions 4 and 5 of the 16S rRNA gene. We additionally demonstrated that modifications tomore » the 515f/806r (variable region 4) 16S primer pair, which improves detection ofThaumarchaeotaand clade SAR11 in marine samples, do not degrade performance on taxa already amplified effectively by the original primer set. Alterations to the fungal ITS primers did result in differential but overall improved performance compared to the original primers. In both cases, the improved primers should be widely adopted for amplicon studies. ImportanceWe continue to uncover a wealth of information connecting microbes in important ways to human and environmental ecology. As our scientific knowledge and technical abilities improve, the tools used for microbiome surveys can be modified to improve the accuracy of our techniques, ensuring that we can continue to identify groundbreaking connections between microbes and the ecosystems they populate, from ice caps to the human body. It is important to confirm that modifications to these tools do not cause new, detrimental biases that would inhibit the field rather than continue to move it forward. We therefore demonstrated that two recently modified primer pairs that target taxonomically discriminatory regions of bacterial and fungal genomic DNA do not introduce new biases when used on a variety of sample types, from soil to human skin. This confirms the utility of these primers for maintaining currently recommended microbiome research techniques as the state of the art.« less

  4. Laboratory blood analysis in Strigiformes-Part I: hematologic reference intervals and agreement between manual blood cell counting techniques.

    PubMed

    Ammersbach, Mélanie; Beaufrère, Hugues; Gionet Rollick, Annick; Tully, Thomas

    2015-03-01

    While hematologic reference intervals (RI) are available for multiple raptorial species of the order Accipitriformes and Falconiformes, there is a lack of valuable hematologic information in Strigiformes that can be used for diagnostic and health monitoring purposes. The objective was to report RI in Strigiformes for hematologic variables and to assess agreement between manual cell counting techniques. A multi-center prospective study was designed to assess hematologic RI and blood cell morphology in owl species. Samples were collected from individuals representing 13 Strigiformes species, including Great Horned Owl, Snowy Owl, Eurasian Eagle Owl, Barred Owl, Great Gray Owl, Ural Owl, Northern Saw-Whet Owls, Northern Hawk Owl, Spectacled Owl, Barn Owl, Eastern Screech Owl, Long-Eared Owl, and Short-Eared Owl. Red blood cell count was determined manually using a hemocytometer. White blood cell count was determined using 3 manual counting techniques: (1) phloxine B technique, (2) Natt and Herrick technique, and (3) estimation from the smear. Differential counts and blood cell morphology were determined on smears. Reference intervals were determined and agreement between methods was calculated. Important species-specific differences were observed in blood cell counts and granulocyte morphology. Differences in WBC count between species did not appear to be predictable based on phylogenetic relationships. Overall, most boreal owl species exhibited a lower WBC count than other species. Important disagreements were found between different manual WBC counting techniques. Disagreements observed between manual counting techniques suggest that technique-specific RI should be used in Strigiformes. © 2015 American Society for Veterinary Clinical Pathology.

  5. Analytical toxicology.

    PubMed

    Flanagan, R J; Widdop, B; Ramsey, J D; Loveland, M

    1988-09-01

    1. Major advances in analytical toxicology followed the introduction of spectroscopic and chromatographic techniques in the 1940s and early 1950s and thin layer chromatography remains important together with some spectrophotometric and other tests. However, gas- and high performance-liquid chromatography together with a variety of immunoassay techniques are now widely used. 2. The scope and complexity of forensic and clinical toxicology continues to increase, although the compounds for which emergency analyses are needed to guide therapy are few. Exclusion of the presence of hypnotic drugs can be important in suspected 'brain death' cases. 3. Screening for drugs of abuse has assumed greater importance not only for the management of the habituated patient, but also in 'pre-employment' and 'employment' screening. The detection of illicit drug administration in sport is also an area of increasing importance. 4. In industrial toxicology, the range of compounds for which blood or urine measurements (so called 'biological monitoring') can indicate the degree of exposure is increasing. The monitoring of environmental contaminants (lead, chlorinated pesticides) in biological samples has also proved valuable. 5. In the near future a consensus as to the units of measurement to be used is urgently required and more emphasis will be placed on interpretation, especially as regards possible behavioural effects of drugs or other poisons. Despite many advances in analytical techniques there remains a need for reliable, simple tests to detect poisons for use in smaller hospital and other laboratories.

  6. Microphysical, microchemical and adhesive properties of lunar material. 3: Gas interaction with lunar material

    NASA Technical Reports Server (NTRS)

    Grossman, J. J.; Mukherjee, N. R.; Ryan, J. A.

    1972-01-01

    Knowledge of the reactivity of lunar material surfaces is important for understanding the effects of the lunar or space environment upon this material, particularly its nature, behavior and exposure history in comparison to terrestrial materials. Adsorptive properties are one of the important techniques for such studies. Gas adsorption measurements were made on an Apollo 12 ultrahigh vacuum-stored sample and Apollo 14 and 15 N2-stored samples. Surface area measurements were made on the latter two. Adsorbate gases used were N2, A, O2 and H2O. Krypton was used for the surface area determinations. Runs were made at room and liquid nitrogen temperature in volumetric and gravimetric systems. It was found that the adsorptive/desorptive behavior was in general significantly different from that of terrestrial materials of similar type and form. Specifically (1) the UHV-stored sample exhibited very high initial adsorption indicative of high surface reactivity, and (2) the N2-stored samples at room and liquid nitrogen temperatures showed that more gas was desorbed than introduced during adsorption, indicative of gas release from the samples. The high reactivity is a scribed cosmic ray track and solar wind damage.

  7. Hybrid setup for micro- and nano-computed tomography in the hard X-ray range

    NASA Astrophysics Data System (ADS)

    Fella, Christian; Balles, Andreas; Hanke, Randolf; Last, Arndt; Zabler, Simon

    2017-12-01

    With increasing miniaturization in industry and medical technology, non-destructive testing techniques are an area of ever-increasing importance. In this framework, X-ray microscopy offers an efficient tool for the analysis, understanding, and quality assurance of microscopic samples, in particular as it allows reconstructing three-dimensional data sets of the whole sample's volume via computed tomography (CT). The following article describes a compact X-ray microscope in the hard X-ray regime around 9 keV, based on a highly brilliant liquid-metal-jet source. In comparison to commercially available instruments, it is a hybrid that works in two different modes. The first one is a micro-CT mode without optics, which uses a high-resolution detector to allow scans of samples in the millimeter range with a resolution of 1 μm. The second mode is a microscope, which contains an X-ray optical element to magnify the sample and allows resolving 150 nm features. Changing between the modes is possible without moving the sample. Thus, the instrument represents an important step towards establishing high-resolution laboratory-based multi-mode X-ray microscopy as a standard investigation method.

  8. Trace elemental analysis of glass and paint samples of forensic interest by ICP-MS using laser ablation solid sample introduction

    NASA Astrophysics Data System (ADS)

    Almirall, Jose R.; Trejos, Tatiana; Hobbs, Andria; Furton, Kenneth G.

    2003-09-01

    The importance of small amounts of glass and paint evidence as a means to associate a crime event to a suspect or a suspect to another individual has been demonstrated in many cases. Glass is a fragile material that is often found at the scenes of crimes such as burglaries, hit-and-run accidents and violent crime offenses. Previous work has demonstrated the utility of elemental analysis by solution ICP-MS of small amounts of glass for the comparison between a fragment found at a crime scene to a possible source of the glass. The multi-element capability and the sensitivity of ICP-MS combined with the simplified sample introduction of laser ablation prior to ion detection provides for an excellent and relatively non-destructive technique for elemental analysis of glass fragments. The direct solid sample introduction technique of laser ablation (LA) is reported as an alternative to the solution method. Direct solid sampling provides several advantages over solution methods and shows great potential for a number of solid sample analyses in forensic science. The advantages of laser ablation include the simplification of sample preparation, thereby reducing the time and complexity of the analysis, the elimination of handling acid dissolution reagents such as HF and the reduction of sources of interferences in the ionization plasma. Direct sampling also provides for essentially "non-destructive" sampling due to the removal of very small amounts of sample needed for analysis. The discrimination potential of LA-ICP-MS is compared with previously reported solution ICP-MS methods using external calibration with internal standardization and a newly reported solution isotope dilution (ID) method. A total of ninety-one different glass samples were used for the comparison study using the techniques mentioned. One set consisted of forty-five headlamps taken from a variety of automobiles representing a range of twenty years of manufacturing dates. A second set consisted of forty-six automotive glasses (side windows and windshields) representing casework glass from different vehicle manufacturers over several years was also characterized by RI and elemental composition analysis. The solution sample introduction techniques (external calibration and isotope dilution) provide for excellent sensitivity and precision but have the disadvantages of destroying the sample and also involve complex sample preparation. The laser ablation method was simpler, faster and produced comparable discrimination to the EC-ICP-MS and ID-ICP-MS. LA-ICP-MS can provide for an excellent alternative to solution analysis of glass in forensic casework samples. Paints and coatings are frequently encountered as trace evidence samples submitted to forensic science laboratories. A LA-ICP-MS method has been developed to complement the commonly used techniques in forensic laboratories in order to better characterize these samples for forensic purposes. Time-resolved plots of each sample can be compared to associate samples to each other or to discriminate between samples. Additionally, the concentration of lead and the ratios of other elements have been determined in various automotive paints by the reported method. A sample set of eighteen (18) survey automotive paint samples have been analyzed with the developed method in order to determine the utility of LA-ICP-MS and to compare the method to the more commonly used scanning electron microscopy (SEM) method for elemental characterization of paint layers in forensic casework.

  9. Analysis of non-contact and contact probe-to-sample thermal exchange for quantitative measurements of thin film and nanostructure thermal conductivity by the scanning hot probe method

    NASA Astrophysics Data System (ADS)

    Wilson, Adam A.

    The ability to measure thermal properties of thin films and nanostructured materials is an important aspect of many fields of academic study. A strategy especially well-suited for nanoscale investigations of these properties is the scanning hot probe technique, which is unique in its ability to non-destructively interrogate the thermal properties with high resolution, both laterally as well as through the thickness of the material. Strategies to quantitatively determine sample thermal conductivity depend on probe calibration. State of the art calibration strategies assume that the area of thermal exchange between probe and sample does not vary with sample thermal conductivity. However, little investigation has gone into determining whether or not that assumption is valid. This dissertation provides a rigorous study into the probe-to-sample heat transfer through the air gap at diffusive distances for a variety of values of sample thermal conductivity. It is demonstrated that the thermal exchange radius and gap/contact thermal resistance varies with sample thermal conductivity as well as tip-to-sample clearance in non-contact mode. In contact mode, it is demonstrated that higher thermal conductivity samples lead to a reduction in thermal exchange radius for Wollaston probe tips. Conversely, in non-contact mode and in contact mode for sharper probe tips where air contributes the most to probe-to-sample heat transfer, the opposite trend occurs. This may be attributed to the relatively strong solid-to-solid conduction occurring between probe and sample for the Wollaston probes. A three-dimensional finite element (3DFE) model was developed to investigate how the calibrated thermal exchange parameters vary with sample thermal conductivity when calibrating the probe via the intersection method in non-contact mode at diffusive distances. The 3DFE model was then used to explore the limits of sensitivity of the experiment for a range of simulated experimental conditions. It is determined that, when operating the scanning hot probe technique in air at standard temperature and pressure using Wollaston probes, the technique is capable of measuring, within 20% uncertainty, samples with values of thermal conductivity up to 10 Wm-1K-1 in contact mode and up to 2 Wm-1K-1 in non-contact mode. By increasing the thermal conductivity of the probe's surroundings (i.e. changing air to a more conductive gas), sensitivity in non-contact mode to sample thermal conductivity is improved, which suggests potential for future investigations using non-contact scanning hot probe to measure thermal conductivity of higher thermal conductivity samples. The ability of the technique to differentiate thin films from the substrate is investigated, and the sensitivity of the technique to thin films and samples with anisotropic properties is explored. The models (both analytical and finite element) developed and reported in this dissertation lead to the ability to measure samples which, by the standard procedure before this work, were unable to be accurately measured. While other techniques failed to be able to successfully interrogate the film thermal conductivity of a full set of double-wall carbon nanotubes infused into polymers, the methods developed in this work allowed non-contact scanning hot probe measurements to be successfully performed to obtain the film thermal conductivity for each sample. Finite element simulations accounting for the anisotropy of these thin film on sample materials show similar trends with independently measured in-plane thermal conductivity for the only two (of five) samples in the set which were successfully able to be measured by the independent technique. Investigations in contact mode with high resolution Pd probes, whose probe-to-sample clearance is difficult to control in a repeatable fashion, show that surface roughness affects the thermal contact resistance. This can lead to values of reported sample thermal conductivity which are misleading, when using the standard calibrated thermal exchange parameters on samples with significantly different surface roughness than the calibration samples. This affect was taken into account to report sample thermal conductivity of Bi2Te3 nanoflakes.

  10. Accurate Quantitation and Analysis of Nitrofuran Metabolites, Chloramphenicol, and Florfenicol in Seafood by Ultrahigh-Performance Liquid Chromatography-Tandem Mass Spectrometry: Method Validation and Regulatory Samples.

    PubMed

    Aldeek, Fadi; Hsieh, Kevin C; Ugochukwu, Obiadada N; Gerard, Ghislain; Hammack, Walter

    2018-05-23

    We developed and validated a method for the extraction, identification, and quantitation of four nitrofuran metabolites, 3-amino-2-oxazolidinone (AOZ), 3-amino-5-morpholinomethyl-2-oxazolidinone (AMOZ), semicarbazide (SC), and 1-aminohydantoin (AHD), as well as chloramphenicol and florfenicol in a variety of seafood commodities. Samples were extracted by liquid-liquid extraction techniques, analyzed by ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), and quantitated using commercially sourced, derivatized nitrofuran metabolites, with their isotopically labeled internal standards in-solvent. We obtained recoveries of 90-100% at various fortification levels. The limit of detection (LOD) was set at 0.25 ng/g for AMOZ and AOZ, 1 ng/g for AHD and SC, and 0.1 ng/g for the phenicols. Various extraction methods, standard stability, derivatization efficiency, and improvements to conventional quantitation techniques were also investigated. We successfully applied this method to the identification and quantitation of nitrofuran metabolites and phenicols in 102 imported seafood products. Our results revealed that four of the samples contained residues from banned veterinary drugs.

  11. Detection of peroxyl radicals from polluted air by free radical reaction combined with liquid chromatography signal amplification technique.

    PubMed

    Wang, Guoying; Jia, Shiming; Niu, Xiuli; Liu, Yanrong; Tian, Haoqi; Chen, Xuefu; Shi, Gaofeng

    2018-01-22

    Free radicals play an important role in the oxidizing power of polluted air, the development of aging-related diseases, the formation of ozone, and the production of secondary particulate matter. The high variability of peroxyl radical concentration has prevented the detection of possible trends or distributions in the concentration of free radicals. We present a new method, free radical reaction combined with liquid chromatography photodiode array detection, for identifying and quantifying peroxyl radicals in polluted air. Functionalized graphene was used for loading peroxyl radicals and reactive molecules in air sampling system, which can facilitate reaction kinetics (charge transfers) between peroxyl radicals and reaction molecules. Separation was performed with and without a preliminary exposure of the polluted air sample to reactive molecule(s) system. The integral chromatographic peak areas before and after air sampling are used to quantify the atmospheric peroxyl radicals in polluted air. The utility of the new technique was tested with measurements carried out in the field. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. A Review of Current Methods for Analysis of Mycotoxins in Herbal Medicines

    PubMed Central

    Zhang, Lei; Dou, Xiao-Wen; Zhang, Cheng; Logrieco, Antonio F.; Yang, Mei-Hua

    2018-01-01

    The presence of mycotoxins in herbal medicines is an established problem throughout the entire world. The sensitive and accurate analysis of mycotoxin in complicated matrices (e.g., herbs) typically involves challenging sample pretreatment procedures and an efficient detection instrument. However, although numerous reviews have been published regarding the occurrence of mycotoxins in herbal medicines, few of them provided a detailed summary of related analytical methods for mycotoxin determination. This review focuses on analytical techniques including sampling, extraction, cleanup, and detection for mycotoxin determination in herbal medicines established within the past ten years. Dedicated sections of this article address the significant developments in sample preparation, and highlight the importance of this procedure in the analytical technology. This review also summarizes conventional chromatographic techniques for mycotoxin qualification or quantitation, as well as recent studies regarding the development and application of screening assays such as enzyme-linked immunosorbent assays, lateral flow immunoassays, aptamer-based lateral flow assays, and cytometric bead arrays. The present work provides a good insight regarding the advanced research that has been done and closes with an indication of future demand for the emerging technologies. PMID:29393905

  13. Determination of Coreceptor Usage of Human Immunodeficiency Virus Type 1 from Patient Plasma Samples by Using a Recombinant Phenotypic Assay

    PubMed Central

    Trouplin, Virginie; Salvatori, Francesca; Cappello, Fanny; Obry, Veronique; Brelot, Anne; Heveker, Nikolaus; Alizon, Marc; Scarlatti, Gabriella; Clavel, François; Mammano, Fabrizio

    2001-01-01

    We developed a recombinant virus technique to determine the coreceptor usage of human immunodeficiency virus type 1 (HIV-1) from plasma samples, the source expected to represent the most actively replicating virus population in infected subjects. This method is not subject to selective bias associated with virus isolation in culture, a step required for conventional tropism determination procedures. The addition of a simple subcloning step allowed semiquantitative evaluation of virus populations with a different coreceptor (CCR5 or CXCR4) usage specificity present in each plasma sample. This procedure detected mixtures of CCR5- and CXCR4-exclusive virus populations as well as dualtropic viral variants, in variable proportions. Sequence analysis of dualtropic clones indicated that changes in the V3 loop are necessary for the use of CXCR4 as a coreceptor, but the overall context of the V1-V3 region is important to preserve the capacity to use CCR5. This convenient technique can greatly assist the study of virus evolution and compartmentalization in infected individuals. PMID:11119595

  14. Use of an ion mobility spectrometer for detecting uranium compounds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McLain, Derek R.; Steeb, Jennifer L.; Smith, Nicholas A.

    The safeguards community currently lacks a method to rapidly determine the chemical form of radioactive and non-radioactive compounds in real time during inspection activities. Chemical speciation identification can provide important information on both the types of materials that are collected during environmental sampling and can inform inspectors as to where to focus efforts during inspections or complementary access visits. Ion Mobility Spectrometry (IMS) is an established field technique for the detection of explosives, narcotics, and other organic compounds. More recently, electrospray ionization (ESI) has been used to introduce inorganic compounds to IMS instruments for analysis. These techniques have shown themore » ability to supply chemical information about the compounds being analyzed. Although these laboratory based instruments use a liquid-based injection system, there is evidence in the literature of unaltered and intact pharmaceutical tablets being volatilized and ionized in open atmosphere using heat and a Ni-63 source. Lastly, this work determined that a commercial-off-the-shelf (COTS) IMS could be used for the identification of solid uranium compounds directly after sampling using a COTS sample swipe.« less

  15. Characterizing Thermal Properties of Melting Te Semiconductor: Thermal Diffusivity Measurements and Simulation

    NASA Technical Reports Server (NTRS)

    Zhu, Shen; Li, C.; Su, Ching-Hua; Lin, B.; Ben, H.; Scripa, R. N.; Lehoczky, S. L.; Curreri, Peter A. (Technical Monitor)

    2002-01-01

    Tellurium is an element for many II-VI and I-III-VI(sub 2) compounds that are useful materials for fabricating many devices. In the melt growth techniques, the thermal properties of the molten phase are important parameter for controlling growth process to improve semiconducting crystal quality. In this study, thermal diffusivity of molten tellurium has been measured by a laser flash method in the temperature range from 500 C to 900 C. A pulsed laser with 1064 nm wavelength is focused on one side of the measured sample. The thermal diffusivity can be estimated from the temperature transient at the other side of the sample. A numerical simulation based on the thermal transport process has been also performed. By numerically fitting the experimental results, both the thermal conductivity and heat capacity can be derived. A relaxation phenomenon, which shows a slow drift of the measured thermal conductivity toward the equilibrium value after cooling of the sample, was observed for the first time. The error analysis and the comparison of the results to published data measured by other techniques will be discussed.

  16. Characterizing Thermal Properties of Melting Te Semiconductor: Thermal Diffusivity Measurements and Simulation

    NASA Technical Reports Server (NTRS)

    Zhu, Shen; Su, Ching-Hua; Li, C.; Lin, B.; Ben, H.; Scripa, R. N.; Lehoczky, S. L.; Curreri, Peter A. (Technical Monitor)

    2002-01-01

    Tellurium is an element for many II-VI and I-III-VI(sub 2) compounds that are useful materials for fabricating many devises. In the melt growth techniques, the thermal properties of the molten phase are important parameter for controlling growth process to improve semiconducting crystal quality. In this study, thermal diffusivity of molten tellurium has been measured by a laser flash method in the temperature range from 500 C to 900 C. A pulsed laser with 1064 nm wavelength is focused on one side of the measured sample. The thermal diffusivity can be estimated from the temperature transient at the other side of the sample. A numerical simulation based on the thermal transport process has been also performed. By numerically fitting the experimental results, both the thermal conductivity and heat capacity can be derived. A relaxation phenomenon, which shows a slow drift of the measured thermal conductivity toward the equilibrium value after cooling of the sample, was observed for the first time. The error analysis and the comparison of the results to published data measured by other techniques will be discussed in the presentation.

  17. Use of an ion mobility spectrometer for detecting uranium compounds

    DOE PAGES

    McLain, Derek R.; Steeb, Jennifer L.; Smith, Nicholas A.

    2018-03-09

    The safeguards community currently lacks a method to rapidly determine the chemical form of radioactive and non-radioactive compounds in real time during inspection activities. Chemical speciation identification can provide important information on both the types of materials that are collected during environmental sampling and can inform inspectors as to where to focus efforts during inspections or complementary access visits. Ion Mobility Spectrometry (IMS) is an established field technique for the detection of explosives, narcotics, and other organic compounds. More recently, electrospray ionization (ESI) has been used to introduce inorganic compounds to IMS instruments for analysis. These techniques have shown themore » ability to supply chemical information about the compounds being analyzed. Although these laboratory based instruments use a liquid-based injection system, there is evidence in the literature of unaltered and intact pharmaceutical tablets being volatilized and ionized in open atmosphere using heat and a Ni-63 source. Lastly, this work determined that a commercial-off-the-shelf (COTS) IMS could be used for the identification of solid uranium compounds directly after sampling using a COTS sample swipe.« less

  18. Coliform species recovered from untreated surface water and drinking water by the membrane filter, standard, and modified most-probable-number techniques.

    PubMed Central

    Evans, T M; LeChevallier, M W; Waarvick, C E; Seidler, R J

    1981-01-01

    The species of total coliform bacteria isolated from drinking water and untreated surface water by the membrane filter (MF), the standard most-probable-number (S-MPN), and modified most-probable-number (M-MPN) techniques were compared. Each coliform detection technique selected for a different profile of coliform species from both types of water samples. The MF technique indicated that Citrobacter freundii was the most common coliform species in water samples. However, the fermentation tube techniques displayed selectivity towards the isolation of Escherichia coli and Klebsiella. The M-MPN technique selected for more C. freundii and Enterobacter spp. from untreated surface water samples and for more Enterobacter and Klebsiella spp. from drinking water samples than did the S-MPN technique. The lack of agreement between the number of coliforms detected in a water sample by the S-MPN, M-MPN, and MF techniques was a result of the selection for different coliform species by the various techniques. PMID:7013706

  19. Clinical forensic sample collection techniques following consensual intercourse in volunteers - cervical canal brush compared to conventional swabs.

    PubMed

    Joki-Erkkilä, Minna; Tuomisto, Sari; Seppänen, Mervi; Huhtala, Heini; Ahola, Arja; Rainio, Juha; Karhunen, Pekka J

    2014-10-01

    The purpose of the research was to evaluate gynecological evidence collection techniques; the benefit of cervical canal brush sample compared to vaginal fornix and cervical swab samples and the time frame for detecting Y-chromosomal material QiAmp DNA Mini Kit(®) and Quantifiler Y Human Male DNA Quantification Kit(®) in adult volunteers following consensual intercourse. Eighty-four adult female volunteers following consensual intercourse were recruited for the study. By combining all sample collecting techniques, 81.0% of the volunteers were Y-DNA positive. Up to 60 h the conventional swab sampling techniques detected more Y-DNA positive samples when compared to the brush technique. However, after 60 h, the cervical canal brush sample technique showed its benefit by detecting 27.3% (6/22) of Y-DNA positive samples, which were Y-DNA negative in both conventional swab sampling techniques. By combining swab and brush techniques, 75% of the volunteers were still Y-DNA positive in 72-144 post-coital hours. The rate of measurable Y-DNA decreased approximately 3% per hour. Despite reported consensual intercourse, 6.8% (3/44) of volunteers were Y-DNA negative within 48 h. Y-DNA was not detected after 144 post-coital hours (6 days). In conclusion, the brush as a forensic evidence collection method may provide additional biological trace evidence from the cervical canal, although the best biological trace evidence collection can be obtained by combining all three sampling techniques. The time frame for gynecological forensic evidence sample collection should be considered to be at least a week if sexual violence is suspected. Copyright © 2014 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  20. Scrambled eggs: A highly sensitive molecular diagnostic workflow for Fasciola species specific detection from faecal samples

    PubMed Central

    Calvani, Nichola Eliza Davies; Windsor, Peter Andrew; Bush, Russell David

    2017-01-01

    Background Fasciolosis, due to Fasciola hepatica and Fasciola gigantica, is a re-emerging zoonotic parasitic disease of worldwide importance. Human and animal infections are commonly diagnosed by the traditional sedimentation and faecal egg-counting technique. However, this technique is time-consuming and prone to sensitivity errors when a large number of samples must be processed or if the operator lacks sufficient experience. Additionally, diagnosis can only be made once the 12-week pre-patent period has passed. Recently, a commercially available coprological antigen ELISA has enabled detection of F. hepatica prior to the completion of the pre-patent period, providing earlier diagnosis and increased throughput, although species differentiation is not possible in areas of parasite sympatry. Real-time PCR offers the combined benefits of highly sensitive species differentiation for medium to large sample sizes. However, no molecular diagnostic workflow currently exists for the identification of Fasciola spp. in faecal samples. Methodology/Principal findings A new molecular diagnostic workflow for the highly-sensitive detection and quantification of Fasciola spp. in faecal samples was developed. The technique involves sedimenting and pelleting the samples prior to DNA isolation in order to concentrate the eggs, followed by disruption by bead-beating in a benchtop homogeniser to ensure access to DNA. Although both the new molecular workflow and the traditional sedimentation technique were sensitive and specific, the new molecular workflow enabled faster sample throughput in medium to large epidemiological studies, and provided the additional benefit of speciation. Further, good correlation (R2 = 0.74–0.76) was observed between the real-time PCR values and the faecal egg count (FEC) using the new molecular workflow for all herds and sampling periods. Finally, no effect of storage in 70% ethanol was detected on sedimentation and DNA isolation outcomes; enabling transport of samples from endemic to non-endemic countries without the requirement of a complete cold chain. The commercially-available ELISA displayed poorer sensitivity, even after adjustment of the positive threshold (65–88%), compared to the sensitivity (91–100%) of the new molecular diagnostic workflow. Conclusions/Significance Species-specific assays for sensitive detection of Fasciola spp. enable ante-mortem diagnosis in both human and animal settings. This includes Southeast Asia where there are potentially many undocumented human cases and where post-mortem examination of production animals can be difficult. The new molecular workflow provides a sensitive and quantitative diagnostic approach for the rapid testing of medium to large sample sizes, potentially superseding the traditional sedimentation and FEC technique and enabling surveillance programs in locations where animal and human health funding is limited. PMID:28915255

  1. Analysis of defect structure in silicon. Characterization of SEMIX material. Silicon sheet growth development for the large area silicon sheet task of the low-cost solar array project

    NASA Technical Reports Server (NTRS)

    Natesh, R.; Stringfellow, G. B.; Virkar, A. V.; Dunn, J.; Guyer, T.

    1983-01-01

    Statistically significant quantitative structural imperfection measurements were made on samples from ubiquitous crystalline process (UCP) Ingot 5848 - 13C. Important correlation was obtained between defect densities, cell efficiency, and diffusion length. Grain boundary substructure displayed a strong influence on the conversion efficiency of solar cells from Semix material. Quantitative microscopy measurements gave statistically significant information compared to other microanalytical techniques. A surface preparation technique to obtain proper contrast of structural defects suitable for quantimet quantitative image analyzer (QTM) analysis was perfected and is used routinely. The relationships between hole mobility and grain boundary density was determined. Mobility was measured using the van der Pauw technique, and grain boundary density was measured using quantitative microscopy technique. Mobility was found to decrease with increasing grain boundary density.

  2. Characterization of aroma compounds in apple cider using solvent-assisted flavor evaporation and headspace solid-phase microextraction.

    PubMed

    Xu, Yan; Fan, Wenlai; Qian, Michael C

    2007-04-18

    The aroma-active compounds in two apple ciders were identified using gas chromatography-olfactometry (GC-O) and GC-mass spectrometry (MS) techniques. The volatile compounds were extracted using solvent-assisted flavor evaporation (SAFE) and headspace solid-phase microextraction (HS-SPME). On the basis of odor intensity, the most important aroma compounds in the two apple cider samples were 2-phenylethanol, butanoic acid, octanoic acid, 2-methylbutanoic acid, 2-phenylethyl acetate, ethyl 2-methylbutanoate, ethyl butanoate, ethyl hexanoate, 4-ethylguaiacol, eugenol, and 4-vinylphenol. Sulfur-containing compounds, terpene derivatives, and lactones were also detected in ciders. Although most of the aroma compounds were common in both ciders, the aroma intensities were different. Comparison of extraction techniques showed that the SAFE technique had a higher recovery for acids and hydroxy-containing compounds, whereas the HS-SPME technique had a higher recovery for esters and highly volatile compounds.

  3. Biosensor-based microRNA detection: techniques, design, performance, and challenges.

    PubMed

    Johnson, Blake N; Mutharasan, Raj

    2014-04-07

    The current state of biosensor-based techniques for amplification-free microRNA (miRNA) detection is critically reviewed. Comparison with non-sensor and amplification-based molecular techniques (MTs), such as polymerase-based methods, is made in terms of transduction mechanism, associated protocol, and sensitivity. Challenges associated with miRNA hybridization thermodynamics which affect assay selectivity and amplification bias are briefly discussed. Electrochemical, electromechanical, and optical classes of miRNA biosensors are reviewed in terms of transduction mechanism, limit of detection (LOD), time-to-results (TTR), multiplexing potential, and measurement robustness. Current trends suggest that biosensor-based techniques (BTs) for miRNA assay will complement MTs due to the advantages of amplification-free detection, LOD being femtomolar (fM)-attomolar (aM), short TTR, multiplexing capability, and minimal sample preparation requirement. Areas of future importance in miRNA BT development are presented which include focus on achieving high measurement confidence and multiplexing capabilities.

  4. Comments on: Accuracy of Raman Lidar Water Vapor Calibration and its Applicability to Long-Term Measurements

    NASA Technical Reports Server (NTRS)

    Whiteman, David N.; Venable, Demetrius; Landulfo, Eduardo

    2012-01-01

    In a recent publication, LeBlanc and McDermid proposed a hybrid calibration technique for Raman water vapor lidar involving a tungsten lamp and radiosondes. Measurements made with the lidar telescope viewing the calibration lamp were used to stabilize the lidar calibration determined by comparison with radiosonde. The technique provided a significantly more stable calibration constant than radiosondes used alone. The technique involves the use of a calibration lamp in a fixed position in front of the lidar receiver aperture. We examine this configuration and find that such a configuration likely does not properly sample the full lidar system optical efficiency. While the technique is a useful addition to the use of radiosondes alone for lidar calibration, it is important to understand the scenarios under which it will not provide an accurate quantification of system optical efficiency changes. We offer examples of these scenarios.

  5. Component Pin Recognition Using Algorithms Based on Machine Learning

    NASA Astrophysics Data System (ADS)

    Xiao, Yang; Hu, Hong; Liu, Ze; Xu, Jiangchang

    2018-04-01

    The purpose of machine vision for a plug-in machine is to improve the machine’s stability and accuracy, and recognition of the component pin is an important part of the vision. This paper focuses on component pin recognition using three different techniques. The first technique involves traditional image processing using the core algorithm for binary large object (BLOB) analysis. The second technique uses the histogram of oriented gradients (HOG), to experimentally compare the effect of the support vector machine (SVM) and the adaptive boosting machine (AdaBoost) learning meta-algorithm classifiers. The third technique is the use of an in-depth learning method known as convolution neural network (CNN), which involves identifying the pin by comparing a sample to its training. The main purpose of the research presented in this paper is to increase the knowledge of learning methods used in the plug-in machine industry in order to achieve better results.

  6. Recombinase polymerase amplification applied to plant virus detection and potential implications.

    PubMed

    Babu, Binoy; Ochoa-Corona, Francisco M; Paret, Mathews L

    2018-04-01

    Several isothermal techniques for the detection of plant pathogens have been developed with the advent of molecular techniques. Among them, Recombinase Polymerase Amplification (RPA) is becoming an important technique for the rapid, sensitive and cost-effective detection of plant viruses. The RPA technology has the advantage to be implemented in field-based scenarios because the method requires a minimal sample preparation, and is performed at constant low temperature (37-42 °C). The RPA technique is rapidly becoming a promising tool for use in rapid detection and further diagnostics in plant clinics and monitoring quarantine services. This paper presents a review of studies conducted using RPA for detection/diagnosis of plant viruses with either DNA genomes (Banana bunchy top virus, Bean golden yellow mosaic virus, Tomato mottle virus, Tomato yellow leaf curl virus) or RNA genomes (Little Cherry virus 2, Plum pox virus and Rose rosette virus). Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Optimal model-based sensorless adaptive optics for epifluorescence microscopy.

    PubMed

    Pozzi, Paolo; Soloviev, Oleg; Wilding, Dean; Vdovin, Gleb; Verhaegen, Michel

    2018-01-01

    We report on a universal sample-independent sensorless adaptive optics method, based on modal optimization of the second moment of the fluorescence emission from a point-like excitation. Our method employs a sample-independent precalibration, performed only once for the particular system, to establish the direct relation between the image quality and the aberration. The method is potentially applicable to any form of microscopy with epifluorescence detection, including the practically important case of incoherent fluorescence emission from a three dimensional object, through minor hardware modifications. We have applied the technique successfully to a widefield epifluorescence microscope and to a multiaperture confocal microscope.

  8. Killer whales (Orcinus orca) produce ultrasonic whistles.

    PubMed

    Samarra, Filipa I P; Deecke, Volker B; Vinding, Katja; Rasmussen, Marianne H; Swift, René J; Miller, Patrick J O

    2010-11-01

    This study reports that killer whales, the largest dolphin, produce whistles with the highest fundamental frequencies ever reported in a delphinid. Using wide-band acoustic sampling from both animal-attached (Dtag) and remotely deployed hydrophone arrays, ultrasonic whistles were detected in three Northeast Atlantic populations but not in two Northeast Pacific populations. These results are inconsistent with analyses suggesting a correlation of maximum frequency of whistles with body size in delphinids, indicate substantial intraspecific variation in whistle production in killer whales, and highlight the importance of appropriate acoustic sampling techniques when conducting comparative analyses of sound repertoires.

  9. Driven-dissipative quantum Monte Carlo method for open quantum systems

    NASA Astrophysics Data System (ADS)

    Nagy, Alexandra; Savona, Vincenzo

    2018-05-01

    We develop a real-time full configuration-interaction quantum Monte Carlo approach to model driven-dissipative open quantum systems with Markovian system-bath coupling. The method enables stochastic sampling of the Liouville-von Neumann time evolution of the density matrix thanks to a massively parallel algorithm, thus providing estimates of observables on the nonequilibrium steady state. We present the underlying theory and introduce an initiator technique and importance sampling to reduce the statistical error. Finally, we demonstrate the efficiency of our approach by applying it to the driven-dissipative two-dimensional X Y Z spin-1/2 model on a lattice.

  10. Two-Step Resonance-Enhanced Desorption Laser Mass Spectrometry for In Situ Analysis of Organic-Rich Environments

    NASA Technical Reports Server (NTRS)

    Getty, S. A.; Grubisic, A.; Uckert, K.; Li, X.; Cornish, T.; Cook, J. E.; Brinckerhoff, W. B.

    2016-01-01

    A wide diversity of planetary surfaces in the solar system represent high priority targets for in situ compositional and contextual analysis as part of future missions. The planned mission portfolio will inform our knowledge of the chemistry at play on Mars, icy moons, comets, and primitive asteroids, which can lead to advances in our understanding of the interplay between inorganic and organic building blocks that led to the evolution of habitable environments on Earth and beyond. In many of these environments, the presence of water or aqueously altered mineralogy is an important indicator of habitable environments that are present or may have been present in the past. As a result, the search for complex organic chemistry that may imply the presence of a feedstock, if not an inventory of biosignatures, is naturally aligned with targeted analyses of water-rich surface materials. Here we describe the two-step laser mass spectrometry (L2MS) analytical technique that has seen broad application in the study of organics in meteoritic samples, now demonstrated to be compatible with an in situ investigation with technique improvements to target high priority planetary environments as part of a future scientific payload. An ultraviolet (UV) pulsed laser is used in previous and current embodiments of laser desorption/ionization mass spectrometry (LDMS) to produce ionized species traceable to the mineral and organic composition of a planetary surface sample. L2MS, an advanced technique in laser mass spectrometry, is selective to the aromatic organic fraction of a complex sample, which can provide additional sensitivity and confidence in the detection of specific compound structures. Use of a compact two-step laser mass spectrometer prototype has been previously reported to provide specificity to key aromatic species, such as PAHs, nucleobases, and certain amino acids. Recent improvements in this technique have focused on the interaction between the mineral matrix and the organic analyte. The majority of planetary targets of astrobiological interest are characterized by the presence of water or hydrated mineral phases. Water signatures can indicate a history of available liquid water that may have played an important role in the chemical environment of these planetary surfaces and subsurfaces. The studies we report here investigate the influence of water content on the detectability of organics by L2MS in planetary analog samples.

  11. Adaptive polynomial chaos techniques for uncertainty quantification of a gas cooled fast reactor transient

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perko, Z.; Gilli, L.; Lathouwers, D.

    2013-07-01

    Uncertainty quantification plays an increasingly important role in the nuclear community, especially with the rise of Best Estimate Plus Uncertainty methodologies. Sensitivity analysis, surrogate models, Monte Carlo sampling and several other techniques can be used to propagate input uncertainties. In recent years however polynomial chaos expansion has become a popular alternative providing high accuracy at affordable computational cost. This paper presents such polynomial chaos (PC) methods using adaptive sparse grids and adaptive basis set construction, together with an application to a Gas Cooled Fast Reactor transient. Comparison is made between a new sparse grid algorithm and the traditionally used techniquemore » proposed by Gerstner. An adaptive basis construction method is also introduced and is proved to be advantageous both from an accuracy and a computational point of view. As a demonstration the uncertainty quantification of a 50% loss of flow transient in the GFR2400 Gas Cooled Fast Reactor design was performed using the CATHARE code system. The results are compared to direct Monte Carlo sampling and show the superior convergence and high accuracy of the polynomial chaos expansion. Since PC techniques are easy to implement, they can offer an attractive alternative to traditional techniques for the uncertainty quantification of large scale problems. (authors)« less

  12. Toward in situ x-ray diffraction imaging at the nanometer scale

    NASA Astrophysics Data System (ADS)

    Zatsepin, Nadia A.; Dilanian, Ruben A.; Nikulin, Andrei Y.; Gable, Brian M.; Muddle, Barry C.; Sakata, Osami

    2008-08-01

    We present the results of preliminary investigations determining the sensitivity and applicability of a novel x-ray diffraction based nanoscale imaging technique, including simulations and experiments. The ultimate aim of this nascent technique is non-destructive, bulk-material characterization on the nanometer scale, involving three dimensional image reconstructions of embedded nanoparticles and in situ sample characterization. The approach is insensitive to x-ray coherence, making it applicable to synchrotron and laboratory hard x-ray sources, opening the possibility of unprecedented nanometer resolution with the latter. The technique is being developed with a focus on analyzing a technologically important light metal alloy, Al-xCu (where x is 2.0-5.0 %wt). The mono- and polycrystalline samples contain crystallographically oriented, weakly diffracting Al2Cu nanoprecipitates in a sparse, spatially random dispersion within the Al matrix. By employing a triple-axis diffractometer in the non-dispersive setup we collected two-dimensional reciprocal space maps of synchrotron x-rays diffracted from the Al2Cu nanoparticles. The intensity profiles of the diffraction peaks confirmed the sensitivity of the technique to the presence and orientation of the nanoparticles. This is a fundamental step towards in situ observation of such extremely sparse, weakly diffracting nanoprecipitates embedded in light metal alloys at early stages of their growth.

  13. QEMSCAN° (Quantitative Evaluation of Minerals by Scanning Electron Microscopy): capability and application to fracture characterization in geothermal systems

    NASA Astrophysics Data System (ADS)

    Ayling, B.; Rose, P. E.; Zemach, E.; Drakos, P. S.; Petty, S.

    2011-12-01

    Fractures are important conduits for fluids in geothermal systems, and the creation and maintenance of fracture permeability is a fundamental aspect of EGS (Engineered Geothermal System) development. Hydraulic or chemical stimulation techniques are often employed to achieve this. In the case of chemical stimulation, an understanding of the minerals present in the fractures themselves is desirable to better design a stimulation effort (i.e. which chemical to use and how much). Borehole televiewer surveys provide important information about regional and local stress regimes and fracture characteristics (e.g. fracture aperture), and XRD is useful for examining bulk rock mineralogy, but neither technique is able to quantify the distribution of these minerals in fractures. QEMSCAN° is a fully-automated micro-analysis system that enables quantitative chemical analysis of materials and generation of high-resolution mineral maps and images as well as porosity structure. It uses a scanning electron microscopy platform (SEM) with an electron beam source in combination with four energy-dispersive X-ray spectrometers (EDS). The measured backscattered electron and electron-induced secondary X-ray emission spectra are used to classify sample mineralogy. Initial applications of QEMSCAN° technology were predominantly in the minerals industry and application to geothermal problems has remained limited to date. In this pilot study, the potential application of QEMSCAN° technology to fracture characterization was evaluated using samples of representative mineralized fractures in two geothermal systems (Newberry Volcano, Oregon and Brady's geothermal field, Nevada). QEMSCAN° results were compared with XRD and petrographic techniques. Nine samples were analyzed from each field, collected from the drill core in the 1000-1500 m depth range in two shallow wells (GEO-N2 at Newberry Volcano and BCH-3 at Brady's). The samples were prepared as polished thin sections for QEMSCAN° analysis. Results indicate that a sampling resolution of 10 μm is sufficient to resolve fracture morphology and mineral zonation (where multiple episodes of mineralization occurred), and enables relatively fast data acquisition (3 cm2 can be analyzed in approximately 3 hours). Finer resolutions (down to 2.5 μm) take significantly longer, but can be used to provide additional spatial detail in areas of interest after a low resolution (10 μm) scan. Use of XRD data in conjunction with QEMSCAN° data is sometimes needed to distinguish geothermal alteration minerals with similar chemical compositions (clay minerals, micas and chlorite), however overall the technique appears to have excellent potential for geothermal applications.

  14. The distribution and stratification of persistent organic pollutants and fatty acids in bottlenose dolphin (Tursiops truncatus) blubber.

    PubMed

    Ellisor, Debra; McLellan, William; Koopman, Heather; Schwacke, Lori; McFee, Wayne; Kucklick, John

    2013-10-01

    Blubber has been used for decades to monitor exposure of marine mammals to persistent organic pollutants (POPs). However, little is known about POP variability as a function of blubber depth and across the body of the animal. Remote blubber biopsy sampling (e.g, projectile biopsy) is the most common technique used to acquire samples from free-swimming animals, yet such techniques may result in variable sampling. It is important to understand whether blubber stratification or body location affects POP concentration or the concentration of other important blubber constituents such as fatty acids (FA). To investigate the influence of sampling depth and location on POP concentration, full depth blubber samples were taken from one stranded bottlenose dolphin (Tursiops truncatus) at six different body sites to assess variation in FA distribution and contaminant storage with body location. Three of the samples from different body locations were separated into histologically distinct layers to examine the effect of blubber depth and body location on POPs and FAs. In this individual, both POPs and FAs were heterogeneous with blubber depth and body location. POP concentrations were significantly greater in ventral (average ΣPBDEs 1350 ng/g lipid) and anterior (average ΣPCBs 28,700 ng/g lipid) body locations and greater in the superficial blubber layer (average ΣPCBs 35,500 ng/g lipid) when compared to the deep (8390 ng/g lipid) and middle (23,700 ng/g lipid) layers. Proportionally more dietary FAs were found in dorsal blubber and in middle and deep layers relative to other locations while the reverse was true for biosynthesized FAs. Stratification was further examined in blubber from the same body location in five additional stranded bottlenose dolphins. Although FAs were stratified with blubber depth, lipid-normalized POPs were not significantly different with depth, indicating that POP concentrations can vary in an individual with blubber depth though the direction of POP stratification is not consistent among individuals. Published by Elsevier B.V.

  15. Contact technique and concussions in the South African under-18 Coca-Cola Craven Week Rugby tournament.

    PubMed

    Hendricks, Sharief; O'connor, Sam; Lambert, Michael; Brown, James; Burger, Nicholas; Mc Fie, Sarah; Readhead, Clint; Viljoen, Wayne

    2015-01-01

    In rugby union, understanding the techniques and events leading to concussions is important because of the nature of the injury and the severity and potential long-term consequences, particularly in junior players. Proper contact technique is a prerequisite for successful participation in rugby and is a major factor associated with injury. However, the execution of proper contact technique and its relationship to injury has yet to be studied in matches. Therefore, the aim of this study was to compare contact techniques leading to concussion with a representative sample of similarly matched non-injury (NI) contact events. Injury surveillance was conducted at the 2011-2013 under-18 Craven Week Rugby tournaments. Video footage of 10 concussive events (5 tackle, 4 ruck and 1 aerial collision) and 83 NI events were identified (19 tackle, 61 ruck and 3 aerial collisions). Thereafter, each phase of play was analysed using standardised technical proficiency criteria. Overall score for ruck proficiency in concussive events was 5.67 (out of a total of 15) vs. 6.98 for NI events (n = 54) (effect size = 0.52, small). Overall average score for tackler proficiency was 7.25 (n = 4) and 6.67 (n = 15) for injury and NI tackles, respectively (out of 16) (effect size = 0.19, trivial). This is the first study to compare concussion injury contact technique to a player-matched sample of NI contact techniques. Certain individual technical criteria had an effect towards an NI outcome, and others had an effect towards a concussive event, highlighting that failure to execute certain techniques may substantially increase the opportunity for concussion.

  16. High Prevalence of Schistosoma japonicum Infection in Carabao from Samar Province, the Philippines: Implications for Transmission and Control

    PubMed Central

    Gordon, Catherine A.; Acosta, Luz P.; Gray, Darren J.; Olveda, Remigo M.; Jarilla, Blanca; Gobert, Geoffrey N.; Ross, Allen G.; McManus, Donald P.

    2012-01-01

    Schistosoma japonicum is endemic in the Philippines, China and Indonesia, and infects more than 40 mammalian host species, all of which can act as reservoirs of infection. In China, water buffaloes have been shown to be major reservoirs of human infection. However, in the Philippines, carabao have not been considered important reservoir hosts for S. japonicum due to the low prevalence and infection intensities reported, the only exception being a qPCR-based study indicating 51% of carabao were S. japonicum-positive. However, the low prevalence found for the same animals when using conventional copro-parasitological techniques means that there is still confusion about the role of carabao in the transmission of schistosomiasis japonicum. To address this inconsistency, and to shed light on the potential role of carabao in the transmission of S. japonicum in the Philippines, we undertook a pilot survey, collecting fecal samples from animals in Western Samar Province and we used a combination of molecular and copro-parasitological techniques to determine the prevalence and intensity of S. japonicum. We found a high prevalence of S. japonicum in the carabao using a validated real-time PCR (qPCR) and a copro-parasitological tool, the formalin-ethyl acetate sedimentation (FEA-SD) technique. A much lower prevalence of S. japonicum was recorded for the same fecal samples using conventional PCR, the Kato-Katz technique and miracidial hatching. These results suggest that, due to their low diagnostic sensitivity, traditional copro-parasitological techniques underestimate infection in carabao. The use of FEA-SD and qPCR provides a more accurate diagnosis. Based on these findings, the role of bovines in the transmission of S. japonicum appears to be more important in the Philippines than previously recognized, and this may have significant implications for the future control of schistosomiasis there, particularly as, in contrast with previous surveys, we found an unprecedented high prevalence of S. japonicum in humans. PMID:23029571

  17. Bisphosphonates in the Prevention of Post-Traumatic Osteoarthritis

    DTIC Science & Technology

    2014-07-01

    OARSI-describe PTOA scoring system was brought into the lab and 4 individuals have been trained on it. Currently, the safranin-O stained samples are...of chondrocyte proliferation (Ki-67), apoptosis (activated caspase-3), hypertrophy (collagen type X), anabolism, catabolism, and inflammation within...surgery training and technique import into P-PI laboratory complete. o Baseline, DMM-only, and age-matched cohort groups completed for D0 through

  18. The Importance of Practice in the Development of Statistics.

    DTIC Science & Technology

    1983-01-01

    RESOLUTION TEST CHART NATIONAL BUREAU OIF STANDARDS 1963 -A NRC Technical Summary Report #2471 C THE IMORTANCE OF PRACTICE IN to THE DEVELOPMENT OF STATISTICS...component analysis, bioassay, limits for a ratio, quality control, sampling inspection, non-parametric tests , transformation theory, ARIMA time series...models, sequential tests , cumulative sum charts, data analysis plotting techniques, and a resolution of the Bayes - frequentist controversy. It appears

  19. Direct Analysis of Samples of Various Origin and Composition Using Specific Types of Mass Spectrometry.

    PubMed

    Byliński, Hubert; Gębicki, Jacek; Dymerski, Tomasz; Namieśnik, Jacek

    2017-07-04

    One of the major sources of error that occur during chemical analysis utilizing the more conventional and established analytical techniques is the possibility of losing part of the analytes during the sample preparation stage. Unfortunately, this sample preparation stage is required to improve analytical sensitivity and precision. Direct techniques have helped to shorten or even bypass the sample preparation stage; and in this review, we comment of some of the new direct techniques that are mass-spectrometry based. The study presents information about the measurement techniques using mass spectrometry, which allow direct sample analysis, without sample preparation or limiting some pre-concentration steps. MALDI - MS, PTR - MS, SIFT - MS, DESI - MS techniques are discussed. These solutions have numerous applications in different fields of human activity due to their interesting properties. The advantages and disadvantages of these techniques are presented. The trends in development of direct analysis using the aforementioned techniques are also presented.

  20. Validation of a multilevel sampling device to determine the vertical variability of chlorinated solvent in a contaminated aquifer.

    PubMed

    Barnier, C; Palmier, C; Atteia, O

    2013-01-01

    The vertical heterogeneity of contaminant concentrations in aquifers is well known, but obtaining representative samples is still a subject of debate. In this paper, the question arises from sites where numerous fully screened wells exist and there is a need to define the vertical distribution of contaminants. For this purpose, several wells were investigated with different techniques on a site contaminated with chlorinated solvents. A core-bored well shows that a tetrachloroethene (PCE) phase is sitting on and infiltrating a less permeable layer. Downstream of the cored well, the following sampling techniques were compared on fully screened wells: low flow pumping at several depths, pumping between packers and a new multilevel sampler for fully screened wells. Concerning low flow rate pumping, very low gradients were found, which may be due to the existence of vertical flow inside the well or in the gravel pack. Sampling between packers gave results comparable with the cores, separating a layer with PCE and trichloroethene from another one with cis 1,2-dichloroethene and vinyl chloride as major compounds. Detailed sampling according to pumped volume shows that even between packers, cleaning of the inter-packer volume is necessary before each sampling. Lastly, the proposed new multilevel sampler gives results similar to the packers but has the advantages of much faster sampling and a constant vertical positioning, which is fairly important for long-term monitoring in highly stratified aquifers.

  1. Post-acquisition data mining techniques for LC-MS/MS-acquired data in drug metabolite identification.

    PubMed

    Dhurjad, Pooja Sukhdev; Marothu, Vamsi Krishna; Rathod, Rajeshwari

    2017-08-01

    Metabolite identification is a crucial part of the drug discovery process. LC-MS/MS-based metabolite identification has gained widespread use, but the data acquired by the LC-MS/MS instrument is complex, and thus the interpretation of data becomes troublesome. Fortunately, advancements in data mining techniques have simplified the process of data interpretation with improved mass accuracy and provide a potentially selective, sensitive, accurate and comprehensive way for metabolite identification. In this review, we have discussed the targeted (extracted ion chromatogram, mass defect filter, product ion filter, neutral loss filter and isotope pattern filter) and untargeted (control sample comparison, background subtraction and metabolomic approaches) post-acquisition data mining techniques, which facilitate the drug metabolite identification. We have also discussed the importance of integrated data mining strategy.

  2. Reducing statistical uncertainties in simulated organ doses of phantoms immersed in water

    DOE PAGES

    Hiller, Mauritius M.; Veinot, Kenneth G.; Easterly, Clay E.; ...

    2016-08-13

    In this study, methods are addressed to reduce the computational time to compute organ-dose rate coefficients using Monte Carlo techniques. Several variance reduction techniques are compared including the reciprocity method, importance sampling, weight windows and the use of the ADVANTG software package. For low-energy photons, the runtime was reduced by a factor of 10 5 when using the reciprocity method for kerma computation for immersion of a phantom in contaminated water. This is particularly significant since impractically long simulation times are required to achieve reasonable statistical uncertainties in organ dose for low-energy photons in this source medium and geometry. Althoughmore » the MCNP Monte Carlo code is used in this paper, the reciprocity technique can be used equally well with other Monte Carlo codes.« less

  3. Recent advances in rapid and non-destructive assessment of meat quality using hyperspectral imaging

    NASA Astrophysics Data System (ADS)

    Tao, Feifei; Ngadi, Michael

    2016-05-01

    Meat is an important food item in human diet. Its production and consumption has greatly increased in the last decades with the development of economies and improvement of peoples' living standards. However, most of the traditional methods for evaluation of meat quality are time-consuming, laborious, inconsistent and destructive to samples, which make them not appropriate for a fast-paced production and processing environment. Development of innovative and non-destructive optical sensing techniques to facilitate simple, fast, and accurate evaluation of quality are attracting increasing attention in the food industry. Hyperspectral imaging is one of the promising techniques. It integrates the combined merits of imaging and spectroscopic techniques. This paper provides a comprehensive review on recent advances in evaluation of the important quality attributes of meat including color, marbling, tenderness, pH, water holding capacity, and also chemical composition attributes such as moisture content, protein content and fat content in pork, beef and lamb. In addition, the future potential applications and trends of hyperspectral imaging are also discussed in this paper.

  4. An Overview on the Importance of Combining Complementary Analytical Platforms in Metabolomic Research.

    PubMed

    Gonzalez-Dominguez, Alvaro; Duran-Guerrero, Enrique; Fernandez-Recamales, Angeles; Lechuga-Sancho, Alfonso Maria; Sayago, Ana; Schwarz, Monica; Segundo, Carmen; Gonzalez-Dominguez, Raul

    2017-01-01

    The analytical bias introduced by most of the commonly used techniques in metabolomics considerably hinders the simultaneous detection of all metabolites present in complex biological samples. In order to solve this limitation, the combination of complementary approaches is emerging in recent years as the most suitable strategy in order to maximize metabolite coverage. This review article presents a general overview of the most important analytical techniques usually employed in metabolomics: nuclear magnetic resonance, mass spectrometry and hybrid approaches. Furthermore, we emphasize the potential of integrating various tools in the form of metabolomic multi-platforms in order to get a deeper metabolome characterization, for which a revision of the existing literature in this field is provided. This review is not intended to be exhaustive but, rather, to give a practical and concise guide to readers not familiar with analytical chemistry on the considerations to account for the proper selection of the technique to be used in a metabolomic experiment in biomedical research. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  5. Analytical Techniques and Pharmacokinetics of Gastrodia elata Blume and Its Constituents.

    PubMed

    Wu, Jinyi; Wu, Bingchu; Tang, Chunlan; Zhao, Jinshun

    2017-07-08

    Gastrodia elata Blume ( G. elata ), commonly called Tianma in Chinese, is an important and notable traditional Chinese medicine (TCM), which has been used in China as an anticonvulsant, analgesic, sedative, anti-asthma, anti-immune drug since ancient times. The aim of this review is to provide an overview of the abundant efforts of scientists in developing analytical techniques and performing pharmacokinetic studies of G. elata and its constituents, including sample pretreatment methods, analytical techniques, absorption, distribution, metabolism, excretion (ADME) and influence factors to its pharmacokinetics. Based on the reported pharmacokinetic property data of G. elata and its constituents, it is hoped that more studies will focus on the development of rapid and sensitive analytical techniques, discovering new therapeutic uses and understanding the specific in vivo mechanisms of action of G. elata and its constituents from the pharmacokinetic viewpoint in the near future. The present review discusses analytical techniques and pharmacokinetics of G. elata and its constituents reported from 1985 onwards.

  6. Sources of variability in collection and preparation of paint and lead-coating samples.

    PubMed

    Harper, S L; Gutknecht, W F

    2001-06-01

    Chronic exposure of children to lead (Pb) can result in permanent physiological impairment. Since surfaces coated with lead-containing paints and varnishes are potential sources of exposure, it is extremely important that reliable methods for sampling and analysis be available. The sources of variability in the collection and preparation of samples were investigated to improve the performance and comparability of methods and to ensure that data generated will be adequate for its intended use. Paint samples of varying sizes (areas and masses) were collected at different locations across a variety of surfaces including metal, plaster, concrete, and wood. A variety of grinding techniques were compared. Manual mortar and pestle grinding for at least 1.5 min and mechanized grinding techniques were found to generate similar homogenous particle size distributions required for aliquots as small as 0.10 g. When 342 samples were evaluated for sample weight loss during mortar and pestle grinding, 4% had 20% or greater loss with a high of 41%. Homogenization and sub-sampling steps were found to be the principal sources of variability related to the size of the sample collected. Analysis of samples from different locations on apparently identical surfaces were found to vary by more than a factor of two both in Pb concentration (mg cm-2 or %) and areal coating density (g cm-2). Analyses of substrates were performed to determine the Pb remaining after coating removal. Levels as high as 1% Pb were found in some substrate samples, corresponding to more than 35 mg cm-2 Pb. In conclusion, these sources of variability must be considered in development and/or application of any sampling and analysis methodologies.

  7. Analysis of teaching materials of civic education is characterized by the value of character in building an anti-corruption culture

    NASA Astrophysics Data System (ADS)

    Sarmini; Suyanto, Totok; Nadiroh, Ulin

    2018-01-01

    In general, corruption is very harmful to society. One of the efforts in preventing corruption is by the culture of Anti-Corruption Education in the young generation through teaching materials in schools. The research method used is qualitative description. The sample in this research is 60 junior high school teachers of Citizenship Education in Surabaya. Data analysis technique used in this research is descriptive statistic with percentage technique. The result of this research is that it is very important that the value of the character of anti-corruption education in teaching materials to grow in the young generation.

  8. UCMS - A new signal parameter measurement system using digital signal processing techniques. [User Constraint Measurement System

    NASA Technical Reports Server (NTRS)

    Choi, H. J.; Su, Y. T.

    1986-01-01

    The User Constraint Measurement System (UCMS) is a hardware/software package developed by NASA Goddard to measure the signal parameter constraints of the user transponder in the TDRSS environment by means of an all-digital signal sampling technique. An account is presently given of the features of UCMS design and of its performance capabilities and applications; attention is given to such important aspects of the system as RF interface parameter definitions, hardware minimization, the emphasis on offline software signal processing, and end-to-end link performance. Applications to the measurement of other signal parameters are also discussed.

  9. Hyperspectral imaging using the single-pixel Fourier transform technique

    NASA Astrophysics Data System (ADS)

    Jin, Senlin; Hui, Wangwei; Wang, Yunlong; Huang, Kaicheng; Shi, Qiushuai; Ying, Cuifeng; Liu, Dongqi; Ye, Qing; Zhou, Wenyuan; Tian, Jianguo

    2017-03-01

    Hyperspectral imaging technology is playing an increasingly important role in the fields of food analysis, medicine and biotechnology. To improve the speed of operation and increase the light throughput in a compact equipment structure, a Fourier transform hyperspectral imaging system based on a single-pixel technique is proposed in this study. Compared with current imaging spectrometry approaches, the proposed system has a wider spectral range (400-1100 nm), a better spectral resolution (1 nm) and requires fewer measurement data (a sample rate of 6.25%). The performance of this system was verified by its application to the non-destructive testing of potatoes.

  10. Effect of storage temperature on the microbial composition of ready-to-use vegetables.

    PubMed

    Caldera, L; Franzetti, L

    2014-02-01

    Four different salad preparations were investigated from microbiological point of view: two were packaged in air and two under Modified Atmosphere. The samples were stored at 4 and 10 °C, and analysed at established times. Total bacterial count (TBC) was taken as the most relevant index to define their hygiene and quality at both temperatures. Lactic acid bacteria, yeasts and moulds were found only occasionally. In general, the most important factor was the packaging technique: TBC was lower when the product is packed under modified conditions. The packaging technique also influences the microbial population: Gram-negative aerobic rods are dominant in air-packaged products, whilst the presence of Enterobacteriaceae becomes important in salads packaged under Modified Atmosphere. Pseudomonas fluorescens, with all its biovars, was the most frequently found species amongst the aerobic isolates, whilst for the Enterobacteriaceae strains, there was no dominant species.

  11. Sampling of atmospheric carbonyl compounds for determination by liquid chromatography after 2,4-dinitrophenylhydrazine labelling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vairavamurthy, A.; Roberts, J.M.; Newman, L.

    1991-02-01

    Determination of carbonyl compounds in the ambient atmosphere is receiving increasing attention because of the critical role these compounds play as pollutants and as key participants in tropospheric photochemistry. Carbonyls are involved in photochemical reactions as products of the oxidation of hydrocarbons, precursors of oxidants including ozone and peroxycarboxylic nitric anhydrides (PANs), and as sources of free radicals and organic aerosols. A correct understanding and assessment of the role of carbonyls in tropospheric chemistry requires the accurate and precise measurement of these compounds along with their parent and product compounds. Here we discuss some of these important issues along withmore » the different techniques used for time-integrated collection of carbonyls in the DNPH based liquid chromatographic methods because of their complexity, variability and as well their importance; we emphasize the principles, advantages, and limitations of these techniques. 58 refs., 9 figs., 3 tabs.« less

  12. Litter aeration and spread of Salmonella in broilers.

    PubMed

    Bodí, Sara González; Garcia, Arantxa Villagra; García, Santiago Vega; Orenga, Clara Marín

    2013-08-01

    Litter quality in the poultry sector is one of the main parameters of health, productivity, and animal welfare. Therefore, innovative management methods have been developed to improve the quality of litter. One of them is litter aeration (LA) by tumbling. However, there is little information related to the effect of this technique on the spreading of pathogens of public health importance such as Salmonella. In this context, the objective of this study was to determine the epidemiology of Salmonella in poultry farms, when serial LA were implemented during the rearing cycle of broilers. For this purpose, an experimental broiler farm with 3 identical rooms was used in the study. Two rooms were assigned to the LA treatment, and the other one served as the control room. Environmental samples were taken in poultry houses after LA in 4 consecutive weeks at the end of the cycle. All samples collected were analyzed according to the standards of the International Organization for Standardization (ISO 6579:2002, Annex D). The results of this study showed that in the control and treated rooms, the percentage of positive samples for Salmonella decreased in the first 3 LA sessions (LA 1, LA 2, and LA 3). However, in the last LA session of rearing (LA 4), the percentage of positive samples increased from 8.2 to 33.2% in the control room instead the treated rooms where the positive samples decreased (P = 0.017). Thus, the aeration of the litter as litter management technique in poultry broiler production does not increase the shedding or the spread of Salmonella throughout broiler houses. In addition, it could be an effective technique to reduce the infective pressure of this bacterium in several areas of the farm or in certain moments of the rearing period with more risk of multiplication and spreading of Salmonella.

  13. Hindlimb muscle architecture in non-human great apes and a comparison of methods for analysing inter-species variation

    PubMed Central

    Myatt, Julia P; Crompton, Robin H; Thorpe, Susannah K S

    2011-01-01

    By relating an animal's morphology to its functional role and the behaviours performed, we can further develop our understanding of the selective factors and constraints acting on the adaptations of great apes. Comparison of muscle architecture between different ape species, however, is difficult because only small sample sizes are ever available. Further, such samples are often comprised of different age–sex classes, so studies have to rely on scaling techniques to remove body mass differences. However, the reliability of such scaling techniques has been questioned. As datasets increase in size, more reliable statistical analysis may eventually become possible. Here we employ geometric and allometric scaling techniques, and ancovas (a form of general linear model, GLM) to highlight and explore the different methods available for comparing functional morphology in the non-human great apes. Our results underline the importance of regressing data against a suitable body size variable to ascertain the relationship (geometric or allometric) and of choosing appropriate exponents by which to scale data. ancova models, while likely to be more robust than scaling for species comparisons when sample sizes are high, suffer from reduced power when sample sizes are low. Therefore, until sample sizes are radically increased it is preferable to include scaling analyses along with ancovas in data exploration. Overall, the results obtained from the different methods show little significant variation, whether in muscle belly mass, fascicle length or physiological cross-sectional area between the different species. This may reflect relatively close evolutionary relationships of the non-human great apes; a universal influence on morphology of generalised orthograde locomotor behaviours or, quite likely, both. PMID:21507000

  14. Understanding mothers' perceptions of what is important about themselves and parenting.

    PubMed

    Riesch, S K; Coleman, R; Glowacki, J S; Konings, K

    1997-01-01

    The purpose of this article is to report what mothers of young adolescents perceive as important about themselves and parenting. Their perceptions were identified from brief written statements from a sample of 538 mothers of young adolescents. The women's statements were analyzed using content analysis techniques. Six themes emerged. Mothers described the challenges of putting their ideals about parenting into practice, including incorporating or discarding the influence of their own upbringing and the seeking of knowledge and skills to improve their parenting. Mothers described their values and goals. Feelings of self-doubt were made apparent through self-critical comments. Expressions of frustration were evident as were the serious life stressors managed by the sample. Repeated comments identified mothers' emphases on the importance of open family communication. Mothers had developed styles of parenting based on decision-making methods and understanding the child's perspective. We suggest community health nurses use the themes as guidelines for anticipatory guidance with families during adolescence.

  15. Application of Synchrotron Microprobe Methods to Solid-Phase Speciation of Metals and Metalloids in House Dust

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    S Walker; H Jamieson; P Rasmussen

    2011-12-31

    Determination of the source and form of metals in house dust is important to those working to understand human and particularly childhood exposure to metals in residential environments. We report the development of a synchrotron microprobe technique for characterization of multiple metal hosts in house dust. We have applied X-ray fluorescence for chemical characterization and X-ray diffraction for crystal structure identification using microfocused synchrotron X-rays at a less than 10 {micro}m spot size. The technique has been evaluated by application to archived house dust samples containing elevated concentrations of Pb, Zn, and Ba in bedroom dust, and Pb and Asmore » in living room dust. The technique was also applied to a sample of soil from the corresponding garden to identify linkages between indoor and outdoor sources of metals. Paint pigments including white lead (hydrocerussite) and lithopone (wurtzite and barite) are the primary source of Pb, Zn, and Ba in bedroom dust, probably related to renovation activity in the home at the time of sampling. The much lower Pb content in the living room dust shows a relationship to the exterior soil and no specific evidence of Pb and Zn from the bedroom paint pigments. The technique was also successful at confirming the presence of chromated copper arsenate treated wood as a source of As in the living room dust. The results of the study have confirmed the utility of this approach in identifying specific metal forms within the dust.« less

  16. Molecular diagnosis of Rickettsia infection in patients from Tunisia.

    PubMed

    Khrouf, Fatma; Sellami, Hanene; Elleuch, Emna; Hattab, Zouhour; Ammari, Lamia; Khalfaoui, Moncef; Souissi, Jihed; Harrabi, Hejer; M'ghirbi, Youmna; Tiouiri, Hanene; Ben Jemaa, Mounir; Hammami, Adnene; Letaief, Amel; Bouattour, Ali; Znazen, Abir

    2016-07-01

    Diagnosis of rickettsioses had largely benefited from the development of molecular techniques. Unfortunately, in Tunisia, despite the large number of rickettsial cases registered every year, the Rickettsia species remain unidentified. In this study, we aimed to detect the Rickettsia species in clinical samples using molecular tests. A study was established to analyze skin biopsies, cutaneous swabs, and cerebrospinal fluid samples taken from clinically suspected patients to have rickettsial infection. Two molecular techniques were used to detect Rickettsia DNA: quantitative real time PCR (qPCR) and reverse line blot test (RLB). An analysis of the RLB hybridization assay results revealed the presence of Rickettsia DNA in skin biopsies (40.6%) and swabs (46.7%). Rickettsia conorii was the most prevalent identified species among tested samples. Other species of interest include Rickettsia typhi and Rickettsia massiliae. Using qPCR positivity rates in skin biopsies was 63.7% against 80% in swabs. R. conorii was the most frequently detected species, followed by R. typhi. The agreement between the two techniques was 68.6% (kappa=0.33). Molecular tests, especially using specific probes qPCR, allow for a rapid, better and confident diagnosis in clinical practice. They improve the survey of Mediterranean spotted fever which is considered to be the most important rickettsial infection in humans in Tunisia. Copyright © 2016 Elsevier GmbH. All rights reserved.

  17. Matching motivation enhancement treatment to client motivation: re-examining the Project MATCH motivation matching hypothesis.

    PubMed

    Witkiewitz, Katie; Hartzler, Bryan; Donovan, Dennis

    2010-08-01

    The current study was designed to re-examine the motivation matching hypothesis from Project MATCH using growth mixture modeling, an analytical technique that models variation in individual drinking patterns. Secondary data analyses of data from Project MATCH (n = 1726), a large multi-site alcoholism treatment-matching study. Percentage of drinking days was the primary outcome measure, assessed from 1 month to 12 months following treatment. Treatment assignment, alcohol dependence symptoms and baseline percentage of drinking days were included as covariates. The results provided support for the motivation matching hypothesis in the out-patient sample and among females in the aftercare sample: the majority of individuals with lower baseline motivation had better outcomes if assigned to motivation enhancement treatment (MET) compared to those assigned to cognitive behavioral treatment (CBT). In the aftercare sample there was a moderating effect of gender and alcohol dependence severity, whereby males with lower baseline motivation and greater alcohol dependence drank more frequently if assigned to MET compared to those assigned to CBT. Results from the current study lend partial support to the motivation-matching hypothesis and also demonstrated the importance of moderating influences on treatment matching effectiveness. Based upon these findings, individuals with low baseline motivation in out-patient settings and males with low levels of alcohol dependence or females in aftercare settings may benefit more from motivational enhancement techniques than from cognitive-behavioral techniques.

  18. [Application of Raman Spectroscopy Technique to Agricultural Products Quality and Safety Determination].

    PubMed

    Liu, Yan-de; Jin, Tan-tan

    2015-09-01

    The quality and safety of agricultural products and people health are inseparable. Using the conventional chemical methods which have so many defects, such as sample pretreatment, complicated operation process and destroying the samples. Raman spectroscopy as a powerful tool of analysing and testing molecular structure, can implement samples quickly without damage, qualitative and quantitative detection analysis. With the continuous improvement and the scope of the application of Raman spectroscopy technology gradually widen, Raman spectroscopy technique plays an important role in agricultural products quality and safety determination, and has wide application prospects. There have been a lot of related research reports based on Raman spectroscopy detection on agricultural product quality safety at present. For the understanding of the principle of detection and the current development situation of Raman spectroscopy, as well as tracking the latest research progress both at home and abroad, the basic principles and the development of Raman spectroscopy as well as the detection device were introduced briefly. The latest research progress of quality and safety determination in fruits and vegetables, livestock and grain by Raman spectroscopy technique were reviewed deeply. Its technical problems for agricultural products quality and safety determination were pointed out. In addition, the text also briefly introduces some information of Raman spectrometer and the application for patent of the portable Raman spectrometer, prospects the future research and application.

  19. Phase quantification by X-ray photoemission valence band analysis applied to mixed phase TiO2 powders

    NASA Astrophysics Data System (ADS)

    Breeson, Andrew C.; Sankar, Gopinathan; Goh, Gregory K. L.; Palgrave, Robert G.

    2017-11-01

    A method of quantitative phase analysis using valence band X-ray photoelectron spectra is presented and applied to the analysis of TiO2 anatase-rutile mixtures. The valence band spectra of pure TiO2 polymorphs were measured, and these spectral shapes used to fit valence band spectra from mixed phase samples. Given the surface sensitive nature of the technique, this yields a surface phase fraction. Mixed phase samples were prepared from high and low surface area anatase and rutile powders. In the samples studied here, the surface phase fraction of anatase was found to be linearly correlated with photocatalytic activity of the mixed phase samples, even for samples with very different anatase and rutile surface areas. We apply this method to determine the surface phase fraction of P25 powder. This method may be applied to other systems where a surface phase fraction is an important characteristic.

  20. The Significance of A Neglected Romanian Book - "The Methods of the Clinical Laboratory", by Ioan Manta and Alexandru Ciplea.

    PubMed

    Barsu, Cristian

    2017-04-06

    "The Methods of Clinical Laboratory" was the first comprehensive Romanian book in the medical laboratory field, having utility in clinical practice. It was written by Prof. Ioan Manta (1900-1979) and Alexandru Ciplea (1912-1988), both from the Cluj Faculty of Medicine. The volume was published for the first time in 1944, during the refuge of this Faculty in Sibiu, and for the second time in 1947, in Cluj. Our aim is to make a brief analysis of its structure and to put into evidence the importance of this book for the Romanian laboratory medicine, some techniques (e.g. microscopic techniques) keeping their validity until today. The authors made over 800 detailed presentations about: laboratory sampling and preservation techniques, different types of tests and methods for qualitative and quantitative determinations, techniques to prepare various solutions, microbiological culture media, laboratory stains and reagents, as well as maneuvering of some laboratory equipments. For each method, Manta and Ciplea presented: the principle of working method, reagents required, the working technique, mode of calculation, the result and its interpretation. It also includes some laboratory apparatus descriptions, as well as their mode of working. With regard to the scientific value and to the practical utility of this book, it remains a very important milestone in the Romanian medical literature of the XX-th century.

  1. A new tritium monitor design based on plasma source ion implantation technique

    NASA Astrophysics Data System (ADS)

    Nassar, Rafat Mohammad

    Tritium is an important isotope of hydrogen. The availability of tritium in our environment is manifest through both natural and artificial sources. Consequently, the requirement for tritium handling and usage will continue to increase in the future. An important future contributor is nuclear fusion power plants and facilities. Essential safety regulations and procedures require effective monitoring and measurements of tritium concentrations in workplaces. The unique characteristics of tritium impose an important role on the criteria for its detection and measurement. As tritium decays by the emission of soft beta particles, maximum 18 keV, it cannot be readily detected by commonly used detectors. Specially built monitors are required. Additional complications occur due to the presence of other radioactive isotopes or ambient radiation fields and because of the high diffusivity of tritium. When it is in oxidized form it is 25000 times more hazardous biologically than when in elemental form. Therefore, contamination of the monitor is expected and compound specific monitors are important. A summary is given of the various well known methods of detecting tritium-in-air. This covers the direct as well as the indirect measuring techniques, although each has been continually improved and further developed, nevertheless, each has its own limitations. Ionization chambers cannot discriminate against airborne P emitters. Proportional counters have a narrow operating range, 3-4 decades, and have poor performance in relatively high humid environments and require a dry counting gas. Liquid scintillation counters are sensitive, but inspection of the sample is slow and they produce chemical liquid waste. A new way to improve the sensitivity of detecting tritium with plastic scintillators has been developed. The technique is based on a non-line-of-sight implantation of tritium ions into a 20 mum plastic scintillator using a plasma source ion implantation (PSII) technique, This type of source is different, superior to the line-of-sight implantation and requires no additional beam handling. It is capable of implanting ion species in a broad beam configuration into the entire surface of a target. The technique requires a special ion source with special characteristics of the type obtained from a surfatron plasma source. This ion source has a large high ion density plasma with minimum contamination and produces ions of low temperature. It was constructed to ionize the sampled air and to produce a plasma over a wide range of pressure, 4-0.1 mTorr. A plasma source ion implantation cell was designed and constructed using mathematical modeling with personal computer, to optimize the essential variables of the design and to estimate the implantation rate under different operation conditions. Also, a high voltage pulse modulator was designed and constructed to produce a series of 10 musec pulses (up to 2 MHz) with a maximum magnitude of -60 kV. The developed device was capable of ionizing air samples and implanting the resulting ions into a plastic scintillator. Two different methods to enhance the collection and deposition of the tritium ions, have been proposed and assessed. A movable prototype device for monitoring environmental tritium in air has been designed and constructed. Although this prototype was not fully tested, the primary calculations have shown that measurable concentrations of tritium ions can be collected from an air sample, with tritium activity ranging from 0.3 Bq/cm3 down to 0.03 mBq/cm3, in a short time, to the order of seconds, on-line. This sensitivity fulfills the requirement for environmental monitoring.

  2. The Earth Microbiome Project and Global Systems Biology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gilbert, Jack A.; Jansson, Janet K.; Knight, Rob

    Recently, we published the first large-scale analysis of data from the Earth Microbiome Project (1, 2), a truly multidisciplinary research program involving more than 500 scientists and 27,751 samples acquired from 43 countries. These samples represent myriad specimen types and span a wide range of biotic and abiotic factors, geographic locations, and physicochemical properties. The database (https://qiita.ucsd.edu/emp/) is still growing, with over 90,000 amplicon datasets, >500 metagenomic runs, and metabolomics datasets from a similar number of samples. Importantly, the techniques, data and analytical tools are all standardized and publicly accessible, providing a framework to support research at a scale ofmore » integration that just 7 years ago seemed impossible.« less

  3. Preservation of commonly applied fluorescent tracers in complex water samples

    NASA Astrophysics Data System (ADS)

    Cao, Viet; Schaffer, Mario; Jin, Yulan; Licha, Tobias

    2017-06-01

    Water sample preservation and pre-treatment are important steps for achieving accurate and reproductive results from tracer tests. However, this is particularly challenging for complex water mixtures prior to fluorescence analysis. In this study, the interference of iron and calcium precipitation with nine commonly applied conservative tracers, uranine, eosin, 1-naphthalene sulfonate, 1,5-naphthalene disulfonate, 2,6-naphthalene disulfonate, 4-amino-1-naphthalene sulfonate, 6-hydroxy-2-naphthalene sulfonate, 1,3,6-naphthalene trisulfonate, and 1,3,6,8-pyrene tetrasulfonate, was investigated in batch experiments. In general, the observed results are influenced by precipitates. A technique consisting of pH adjustment and centrifugation is described for preserving samples and avoiding the impact of these precipitates on the tracer test results.

  4. Differentials in colostrum feeding among lactating women of block RS Pura of J and K: A lesson for nursing practice.

    PubMed

    Raina, Sunil Kumar; Mengi, Vijay; Singh, Gurdeep

    2012-07-01

    Breast feeding is universally and traditionally practicised in India. Experts advocate breast feeding as the best method of feeding young infants. To assess the role of various factors in determining colostrum feeding in block R. S. Pura of district Jammu. A stratified two-stage design with villages as the primary sampling unit and lactating mothers as secondary sampling unit. Villages were divided into different clusters on the basis of population and sampling units were selected by a simple random technique. Breastfeeding is almost universal in R. S. Pura. Differentials in discarding the first milk were not found to be important among various socioeconomic groups and the phenomenon appeared more general than specific.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Love, S.P.; Goff, F.; Counce, D.

    Volcanic gases provide important insights on the internal workings of volcanoes and changes in their composition and total flux can warn of impending changes in a volcano`s eruptive state. In addition, volcanoes are important contributors to the earth`s atmosphere, and understanding this volcanic contribution is crucial for unraveling the effect of anthropogenic gases on the global climate. Studies of volcanic gases have long relied upon direct in situ sampling, which requires volcanologists to work on-site within a volcanic crater. In recent years, spectroscopic techniques have increasingly been employed to obtain information on volcanic gases from greater distances and thus atmore » reduced risk. These techniques have included UV correlation spectroscopy (Cospec) for SO{sub 2} monitoring, the most widely-used technique, and infrared spectroscopy in a variety of configurations, both open- and closed-path. Francis et al. have demonstrated good results using the sun as the IR source. This solar occultation technique is quite useful, but puts rather strong restrictions on the location of instrument and is thus best suited to more accessible volcanoes. In order to maximize the flexibility and range of FTIR measurements at volcanoes, work over the last few years has emphasized techniques which utilize the strong radiance contrast between the volcanic gas plume and the sky. The authors have successfully employed these techniques at several volcanoes, including the White Island and Ruapehu volcanoes in New Zealand, the Kilauea volcano on Hawaii, and Mt. Etna in Italy. But Popocatepetl (5452 m), the recently re-awakened volcano 70 km southeast of downtown Mexico City, has provided perhaps the best examples to date of the usefulness of these techniques.« less

  6. High Resolution Mass Spectrometry of Seasonal Aerosol Samples From an Urban Location in the Italian Po Valley

    NASA Astrophysics Data System (ADS)

    Mahon, Brendan; Giorio, Chiara; Gallimore, Peter J.; Zielinski, Arthur T.; Tapparo, Andrea; Kalberer, Markus

    2016-04-01

    The Po Valley in Northern Italy represents one of the most polluted environments in Europe, with PM2.5 and ozone concentrations regularly exceeding 100μg/m3 and 50ppb respectively. Particularly during winter, prolonged inversion conditions together with biomass burning and anthropogenic emissions regularly lead to severe air pollution events. Over the course of several months in 2013-14, we carried out a sampling program at a city-centre site in Padova, Italy, collecting 24-hour high-volume aerosol filter samples, 18 in winter (mid December - mid March) and 20 in summer (late May - late July). Utilising high-resolution Orbitrap mass spectrometry techniques, we have characterised these sample sets to examine the long-term variation in aerosol composition over the sampling campaign and to determine the effect of anthropogenic gaseous pollutants such as NOx and SO2 on the composition of organic particle components. The results showed that between ca. 450-700 ions were measured in each sample in both the summer and winter sample sets, however the majority (90%) of ions in the winter samples were below 300m/z and below 380m/z in the summer samples. A much higher percentage of CHO-only ions were found in winter (ca. 27%) compared to the summer samples (ca. 6%), indicating a higher degree of photochemical reactions taking place involving pollutants such as NOx and SO2 in summer. Our results represent the first long term data set of high-resolution measurements of aerosol composition and demonstrate that this technique is an important tool in evaluating the composition of aerosol particles in complex polluted urban areas.

  7. A comparison of five sampling techniques to estimate surface fuel loading in montane forests

    Treesearch

    Pamela G. Sikkink; Robert E. Keane

    2008-01-01

    Designing a fuel-sampling program that accurately and efficiently assesses fuel load at relevant spatial scales requires knowledge of each sample method's strengths and weaknesses.We obtained loading values for six fuel components using five fuel load sampling techniques at five locations in western Montana, USA. The techniques included fixed-area plots, planar...

  8. Application Of Laser Induced Breakdown Spectroscopy (LIBS) Technique In Investigation Of Historical Metal Threads

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abdel-Kareem, O.; Khedr, A.; Abdelhamid, M.

    Analysis of the composition of an object is a necessary step in the documentation of the properties of this object for estimating its condition. Also this is an important task for establishing an appropriate conservation treatment of an object or to follow up the result of the application of the suggested treatments. There has been an important evolution in the methods used for analysis of metal threads since the second half of the twentieth century. Today, the main considerations of selecting a method are based on the diagnostic power, representative sampling, reproducibility, destructive nature/invasiveness of analysis and accessibility to themore » appropriate instrument. This study aims at evaluating the usefulness of the use of Laser Induced Breakdown Spectroscopy (LIBS) Technique for analysis of historical metal threads. In this study various historical metal threads collected from different museums were investigated using (LIBS) technique. For evaluating usefulness of the suggested analytical protocol of this technique, the same investigated metal thread samples were investigated with Scanning Electron Microscope (SEM) with energy-dispersive x-ray analyzer (EDX) which is reported in conservation field as the best method, to determine the chemical composition, and corrosion of investigated metal threads. The results show that all investigated metal threads in the present study are too dirty, strongly damaged and corroded with different types of corrosion products. Laser Induced Breakdown Spectroscopy (LIBS) Technique is considered very useful technique that can be used safely for investigating historical metal threads. It is, in fact, very useful tool as a noninvasive method for analysis of historical metal threads. The first few laser shots are very useful for the investigation of the corrosion and dirt layer, while the following shots are very useful and effective for investigating the coating layer. Higher number of laser shots are very useful for the main composition of the metal thread. There is a necessity to carry out further research to investigate and determine the most appropriate and effective approaches and methods for conservation of these metal threads.« less

  9. Comparison of temporal trends in VOCs as measured with PDB samplers and low-flow sampling methods

    USGS Publications Warehouse

    Harte, P.T.

    2002-01-01

    Analysis of temporal trends in tetrachloroethylene (PCE) concentration determined by two sample techniques showed that passive diffusion bag (pdb) samplers adequately sample the large variation in PCE concentrations at the site. The slopes of the temporal trends in concentrations were comparable between the two techniques, and the pdb sample concentration generally reflected the instantaneous concentration sampled by the low-flow technique. Thus, the pdb samplers provided an appropriate sampling technique for PCE at these wells. One or two wells did not make the case for widespread application of pdb samples at all sites. However, application of pdb samples in some circumstances was appropriate for evaluating temporal and spatial variations in VOC concentrations, thus, should be considered as a useful tool in hydrogeology.

  10. Comparison between McMaster and Mini-FLOTAC methods for the enumeration of Eimeria maxima oocysts in poultry excreta.

    PubMed

    Bortoluzzi, C; Paras, K L; Applegate, T J; Verocai, G G

    2018-04-30

    Monitoring Eimeria shedding has become more important due to the recent restrictions to the use of antibiotics within the poultry industry. Therefore, there is a need for the implementation of more precise and accurate quantitative diagnostic techniques. The objective of this study was to compare the precision and accuracy between the Mini-FLOTAC and the McMaster techniques for quantitative diagnosis of Eimeria maxima oocyst in poultry. Twelve pools of excreta samples of broiler chickens experimentally infected with E. maxima were analyzed for the comparison between Mini-FLOTAC and McMaster technique using, the detection limits (dl) of 23 and 25, respectively. Additionally, six excreta samples were used to compare the precision of different dl (5, 10, 23, and 46) using the Mini-FLOTAC technique. For precision comparisons, five technical replicates of each sample (five replicate slides on one excreta slurry) were read for calculating the mean oocyst per gram of excreta (OPG) count, standard deviation (SD), coefficient of variation (CV), and precision of both aforementioned comparisons. To compare accuracy between the methods (McMaster, and Mini-FLOTAC dl 5 and 23), excreta from uninfected chickens was spiked with 100, 500, 1,000, 5,000, or 10,000 OPG; additional samples remained unspiked (negative control). For each spiking level, three samples were read in triplicate, totaling nine reads per spiking level per technique. Data were transformed using log10 to obtain normality and homogeneity of variances. A significant correlation (R = 0.74; p = 0.006) was observed between the mean OPG of the McMaster dl 25 and the Mini-FLOTAC dl 23. Mean OPG, CV, SD, and precision were not statistically different between the McMaster dl 25 and Mini-FLOTAC dl 23. Despite the absence of statistical difference (p > 0.05), Mini-FLOTAC dl 5 showed a numerically lower SD and CV than Mini-FLOTAC dl 23. The Pearson correlation coefficient revealed significant and positive correlation among the four dl (p ≤ 0.05). In the accuracy study, it was observed that the Mini-FLOTAC dl 5 and 23 were more accurate than the McMaster for 100 OPG, and the Mini-FLOTAC dl 23 had the highest accuracy for 500 OPG. The McMaster and Mini-FLOTAC dl 23 techniques were more accurate than the Mini-FLOTAC dl 5 for 5,000 OPG, and both dl of the Mini-FLOTAC were less accurate for 10,000 OPG counts than the McMaster technique. However, the overall accuracy of the Mini-FLOTAC dl 23 was higher than the McMaster and Mini-FLOTAC dl 5 techniques. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. ZnO/Ag nanocomposite: an efficient catalyst for degradation studies of textile effluents under visible light.

    PubMed

    Saravanan, R; Karthikeyan, N; Gupta, V K; Thirumal, E; Thangadurai, P; Narayanan, V; Stephen, A

    2013-05-01

    Degradation of model organic dye and industry effluent was studied using different weight percentages of Ag into ZnO as a catalyst. In this study, the catalysts were prepared by thermal decomposition method, which was employed for the first time in the preparation of ZnO/Ag nanocomposite catalysts. The physical and chemical properties of the prepared samples were studied using various techniques. The specific surface area, which plays an important role in the photocatalytic degradation, was studied using BET analysis and 10 wt.% Ag into ZnO showed the best degrading efficiency. The optical absorption (UV-vis) and emission (PL) properties of the samples were studied and results suggest better photocatalytic properties for 10 wt.% Ag sample compared to other samples. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  12. Large-volume constant-concentration sampling technique coupling with surface-enhanced Raman spectroscopy for rapid on-site gas analysis

    NASA Astrophysics Data System (ADS)

    Zhang, Zhuomin; Zhan, Yisen; Huang, Yichun; Li, Gongke

    2017-08-01

    In this work, a portable large-volume constant-concentration (LVCC) sampling technique coupling with surface-enhanced Raman spectroscopy (SERS) was developed for the rapid on-site gas analysis based on suitable derivatization methods. LVCC sampling technique mainly consisted of a specially designed sampling cell including the rigid sample container and flexible sampling bag, and an absorption-derivatization module with a portable pump and a gas flowmeter. LVCC sampling technique allowed large, alterable and well-controlled sampling volume, which kept the concentration of gas target in headspace phase constant during the entire sampling process and made the sampling result more representative. Moreover, absorption and derivatization of gas target during LVCC sampling process were efficiently merged in one step using bromine-thiourea and OPA-NH4+ strategy for ethylene and SO2 respectively, which made LVCC sampling technique conveniently adapted to consequent SERS analysis. Finally, a new LVCC sampling-SERS method was developed and successfully applied for rapid analysis of trace ethylene and SO2 from fruits. It was satisfied that trace ethylene and SO2 from real fruit samples could be actually and accurately quantified by this method. The minor concentration fluctuations of ethylene and SO2 during the entire LVCC sampling process were proved to be < 4.3% and 2.1% respectively. Good recoveries for ethylene and sulfur dioxide from fruit samples were achieved in range of 95.0-101% and 97.0-104% respectively. It is expected that portable LVCC sampling technique would pave the way for rapid on-site analysis of accurate concentrations of trace gas targets from real samples by SERS.

  13. Large-volume constant-concentration sampling technique coupling with surface-enhanced Raman spectroscopy for rapid on-site gas analysis.

    PubMed

    Zhang, Zhuomin; Zhan, Yisen; Huang, Yichun; Li, Gongke

    2017-08-05

    In this work, a portable large-volume constant-concentration (LVCC) sampling technique coupling with surface-enhanced Raman spectroscopy (SERS) was developed for the rapid on-site gas analysis based on suitable derivatization methods. LVCC sampling technique mainly consisted of a specially designed sampling cell including the rigid sample container and flexible sampling bag, and an absorption-derivatization module with a portable pump and a gas flowmeter. LVCC sampling technique allowed large, alterable and well-controlled sampling volume, which kept the concentration of gas target in headspace phase constant during the entire sampling process and made the sampling result more representative. Moreover, absorption and derivatization of gas target during LVCC sampling process were efficiently merged in one step using bromine-thiourea and OPA-NH 4 + strategy for ethylene and SO 2 respectively, which made LVCC sampling technique conveniently adapted to consequent SERS analysis. Finally, a new LVCC sampling-SERS method was developed and successfully applied for rapid analysis of trace ethylene and SO 2 from fruits. It was satisfied that trace ethylene and SO 2 from real fruit samples could be actually and accurately quantified by this method. The minor concentration fluctuations of ethylene and SO 2 during the entire LVCC sampling process were proved to be <4.3% and 2.1% respectively. Good recoveries for ethylene and sulfur dioxide from fruit samples were achieved in range of 95.0-101% and 97.0-104% respectively. It is expected that portable LVCC sampling technique would pave the way for rapid on-site analysis of accurate concentrations of trace gas targets from real samples by SERS. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Preparation and Characterization of Microencapsulated Phase Change Materials for Use in Building Applications

    PubMed Central

    Giro-Paloma, Jessica; Al-Shannaq, Refat; Fernández, Ana Inés; Farid, Mohammed M.

    2015-01-01

    A method for preparing and characterizing microencapsulated phase change materials (MPCM) was developed. A comparison with a commercial MPCM is also presented. Both MPCM contained paraffin wax as PCM with acrylic shell. The melting temperature of the PCM was around 21 °C, suitable for building applications. The M-2 (our laboratory made sample) and Micronal® DS 5008 X (BASF) samples were characterized using SEM, DSC, nano-indentation technique, and Gas Chromatography/Mass spectrometry (GC-MS). Both samples presented a 6 μm average size and a spherical shape. Thermal energy storage (TES) capacities were 111.73 J·g−1 and 99.3 J·g−1 for M-2 and Micronal® DS 5008 X, respectively. Mechanical characterization of the samples was performed by nano-indentation technique in order to determine the elastic modulus (E), load at maximum displacement (Pm), and displacement at maximum load (hm), concluding that M-2 presented slightly better mechanical properties. Finally, an important parameter for considering use in buildings is the release of volatile organic compounds (VOC’s). This characteristic was studied at 65 °C by CG-MS. Both samples showed VOC’s emission after 10 min of heating, however peaks intensity of VOC’s generated from M-2 microcapsules showed a lower concentration than Micronal® DS 5008 X. PMID:28787812

  15. Fast X-Ray Fluorescence Microtomography of Hydrated Biological Samples

    PubMed Central

    Lombi, Enzo; de Jonge, Martin D.; Donner, Erica; Kopittke, Peter M.; Howard, Daryl L.; Kirkham, Robin; Ryan, Chris G.; Paterson, David

    2011-01-01

    Metals and metalloids play a key role in plant and other biological systems as some of them are essential to living organisms and all can be toxic at high concentrations. It is therefore important to understand how they are accumulated, complexed and transported within plants. In situ imaging of metal distribution at physiological relevant concentrations in highly hydrated biological systems is technically challenging. In the case of roots, this is mainly due to the possibility of artifacts arising during sample preparation such as cross sectioning. Synchrotron x-ray fluorescence microtomography has been used to obtain virtual cross sections of elemental distributions. However, traditionally this technique requires long data acquisition times. This has prohibited its application to highly hydrated biological samples which suffer both radiation damage and dehydration during extended analysis. However, recent advances in fast detectors coupled with powerful data acquisition approaches and suitable sample preparation methods can circumvent this problem. We demonstrate the heightened potential of this technique by imaging the distribution of nickel and zinc in hydrated plant roots. Although 3D tomography was still impeded by radiation damage, we successfully collected 2D tomograms of hydrated plant roots exposed to environmentally relevant metal concentrations for short periods of time. To our knowledge, this is the first published example of the possibilities offered by a new generation of fast fluorescence detectors to investigate metal and metalloid distribution in radiation-sensitive, biological samples. PMID:21674049

  16. In situ AFM investigation of slow crack propagation mechanisms in a glassy polymer

    NASA Astrophysics Data System (ADS)

    George, M.; Nziakou, Y.; Goerke, S.; Genix, A.-C.; Bresson, B.; Roux, S.; Delacroix, H.; Halary, J.-L.; Ciccotti, M.

    2018-03-01

    A novel experimental technique based on in situ AFM monitoring of the mechanisms of damage and the strain fields associated to the slow steady-state propagation of a fracture in glassy polymers is presented. This micron-scale investigation is complemented by optical measurements of the sample deformation up to the millimetric macroscopic scale of the sample in order to assess the proper crack driving conditions. These multi-scale observations provide important insights towards the modeling of the fracture toughness of glassy polymers and its relationship with the macromolecular structure and non-linear rheological properties. This novel technique is first tested on a standard PMMA thermoplastic in order to both evaluate its performance and the richness of this new kind of observations. Although the fracture propagation in PMMA is well known to proceed through crazing in the bulk of the samples, our observations provide a clear description and quantitative evaluation of a change of fracture mechanism towards shear yielding fracture accompanied by local necking close to the free surface of the sample, which can be explained by the local change of stress triaxiality. Moreover, this primary surface necking mechanism is shown to be accompanied by a network of secondary grooves that can be related to surface crazes propagating towards the interior of the sample. This overall scenario is validated by post-mortem fractographic investigations by scanning electron microscopy.

  17. High-resolution, 2- and 3-dimensional imaging of uncut, unembedded tissue biopsy samples.

    PubMed

    Torres, Richard; Vesuna, Sam; Levene, Michael J

    2014-03-01

    Despite continuing advances in tissue processing automation, traditional embedding, cutting, and staining methods limit our ability for rapid, comprehensive visual examination. These limitations are particularly relevant to biopsies for which immediate therapeutic decisions are most necessary, faster feedback to the patient is desired, and preservation of tissue for ancillary studies is most important. The recent development of improved tissue clearing techniques has made it possible to consider use of multiphoton microscopy (MPM) tools in clinical settings, which could address difficulties of established methods. To demonstrate the potential of MPM of cleared tissue for the evaluation of unembedded and uncut pathology samples. Human prostate, liver, breast, and kidney specimens were fixed and dehydrated by using traditional histologic techniques, with or without incorporation of nucleic acid fluorescent stains into dehydration steps. A benzyl alcohol/benzyl benzoate clearing protocol was substituted for xylene. Multiphoton microscopy was performed on a home-built system. Excellent morphologic detail was achievable with MPM at depths greater than 500 μm. Pseudocoloring produced images analogous to hematoxylin-eosin-stained images. Concurrent second-harmonic generation detection allowed mapping of collagen. Subsequent traditional section staining with hematoxylin-eosin did not reveal any detrimental morphologic effects. Sample immunostains on renal tissue showed preservation of normal reactivity. Complete reconstructions of 1-mm cubic samples elucidated 3-dimensional architectural organization. Multiphoton microscopy on cleared, unembedded, uncut biopsy specimens shows potential as a practical clinical tool with significant advantages over traditional histology while maintaining compatibility with gold standard techniques. Further investigation to address remaining implementation barriers is warranted.

  18. Molecular techniques to distinguish morphologically similar Hydrilla verticillata, Egeria densa, Elodea nuttallii, and Elodea canadensis

    USGS Publications Warehouse

    Rybicki, Nancy B.; Kirshtein, Julie D.; Voytek, Mary A.

    2013-01-01

    The four submerged aquatic species, hydrilla (Hydrilla verticillata [monoecious and dioecious]), Brazilian waterweed (Egeria densa), Canadian waterweed (Elodea canadensis), and western waterweed (Elodea nuttallii), are difficult to positively identify because of their morphological similarity to each other, resulting in possible misidentification. This limits our ability to understand their past and present distribution, which is important in aquatic plant management. We investigated a molecular technique to identify these species, which are problematic because of their invasive nature on multiple continents. Approximately 100 samples of these species, ranging in age from 40-yr-old herbarium samples to recently collected plants, were collected from regions across the United States. The distribution and range of the samples collected in this research were compared to those reported in the literature. We confirmed information on the current wide distribution of both hydrilla biotypes in the United States and discovered that hydrilla had actually invaded the waterways near Washington, DC 6 yr earlier than originally reported. In addition, we found evidence of the confusion, dating back to the 1980s, between Canadian waterweed and western waterweed in the mid-Atlantic region of the United States. Canadian waterweed was previously reported as common and western waterweed as rare; however, our samples indicate the opposite is true. This information indicates there is a need for investigators to anticipate the spread of hydrilla populations to northern U.S. waterways, where it will compete with existing plant species, including Canadian and western waterweeds. Our ability to confirm distribution and pace of spread of invasive and noninvasive species will improve with increased application of molecular techniques.

  19. Efficient sampling of parsimonious inversion histories with application to genome rearrangement in Yersinia.

    PubMed

    Miklós, István; Darling, Aaron E

    2009-06-22

    Inversions are among the most common mutations acting on the order and orientation of genes in a genome, and polynomial-time algorithms exist to obtain a minimal length series of inversions that transform one genome arrangement to another. However, the minimum length series of inversions (the optimal sorting path) is often not unique as many such optimal sorting paths exist. If we assume that all optimal sorting paths are equally likely, then statistical inference on genome arrangement history must account for all such sorting paths and not just a single estimate. No deterministic polynomial algorithm is known to count the number of optimal sorting paths nor sample from the uniform distribution of optimal sorting paths. Here, we propose a stochastic method that uniformly samples the set of all optimal sorting paths. Our method uses a novel formulation of parallel Markov chain Monte Carlo. In practice, our method can quickly estimate the total number of optimal sorting paths. We introduce a variant of our approach in which short inversions are modeled to be more likely, and we show how the method can be used to estimate the distribution of inversion lengths and breakpoint usage in pathogenic Yersinia pestis. The proposed method has been implemented in a program called "MC4Inversion." We draw comparison of MC4Inversion to the sampler implemented in BADGER and a previously described importance sampling (IS) technique. We find that on high-divergence data sets, MC4Inversion finds more optimal sorting paths per second than BADGER and the IS technique and simultaneously avoids bias inherent in the IS technique.

  20. Correcting for Microbial Blooms in Fecal Samples during Room-Temperature Shipping.

    PubMed

    Amir, Amnon; McDonald, Daniel; Navas-Molina, Jose A; Debelius, Justine; Morton, James T; Hyde, Embriette; Robbins-Pianka, Adam; Knight, Rob

    2017-01-01

    The use of sterile swabs is a convenient and common way to collect microbiome samples, and many studies have shown that the effects of room-temperature storage are smaller than physiologically relevant differences between subjects. However, several bacterial taxa, notably members of the class Gammaproteobacteria , grow at room temperature, sometimes confusing microbiome results, particularly when stability is assumed. Although comparative benchmarking has shown that several preservation methods, including the use of 95% ethanol, fecal occult blood test (FOBT) and FTA cards, and Omnigene-GUT kits, reduce changes in taxon abundance during room-temperature storage, these techniques all have drawbacks and cannot be applied retrospectively to samples that have already been collected. Here we performed a meta-analysis using several different microbiome sample storage condition studies, showing consistent trends in which specific bacteria grew (i.e., "bloomed") at room temperature, and introduce a procedure for removing the sequences that most distort analyses. In contrast to similarity-based clustering using operational taxonomic units (OTUs), we use a new technique called "Deblur" to identify the exact sequences corresponding to blooming taxa, greatly reducing false positives and also dramatically decreasing runtime. We show that applying this technique to samples collected for the American Gut Project (AGP), for which participants simply mail samples back without the use of ice packs or other preservatives, yields results consistent with published microbiome studies performed with frozen or otherwise preserved samples. IMPORTANCE In many microbiome studies, the necessity to store samples at room temperature (i.e., remote fieldwork) and the ability to ship samples without hazardous materials that require special handling training, such as ethanol (i.e., citizen science efforts), is paramount. However, although room-temperature storage for a few days has been shown not to obscure physiologically relevant microbiome differences between comparison groups, there are still changes in specific bacterial taxa, notably, in members of the class Gammaproteobacteria , that can make microbiome profiles difficult to interpret. Here we identify the most problematic taxa and show that removing sequences from just a few fast-growing taxa is sufficient to correct microbiome profiles.

  1. Correcting for Microbial Blooms in Fecal Samples during Room-Temperature Shipping

    PubMed Central

    Amir, Amnon; McDonald, Daniel; Navas-Molina, Jose A.; Debelius, Justine; Morton, James T.; Hyde, Embriette; Robbins-Pianka, Adam

    2017-01-01

    ABSTRACT The use of sterile swabs is a convenient and common way to collect microbiome samples, and many studies have shown that the effects of room-temperature storage are smaller than physiologically relevant differences between subjects. However, several bacterial taxa, notably members of the class Gammaproteobacteria, grow at room temperature, sometimes confusing microbiome results, particularly when stability is assumed. Although comparative benchmarking has shown that several preservation methods, including the use of 95% ethanol, fecal occult blood test (FOBT) and FTA cards, and Omnigene-GUT kits, reduce changes in taxon abundance during room-temperature storage, these techniques all have drawbacks and cannot be applied retrospectively to samples that have already been collected. Here we performed a meta-analysis using several different microbiome sample storage condition studies, showing consistent trends in which specific bacteria grew (i.e., “bloomed”) at room temperature, and introduce a procedure for removing the sequences that most distort analyses. In contrast to similarity-based clustering using operational taxonomic units (OTUs), we use a new technique called “Deblur” to identify the exact sequences corresponding to blooming taxa, greatly reducing false positives and also dramatically decreasing runtime. We show that applying this technique to samples collected for the American Gut Project (AGP), for which participants simply mail samples back without the use of ice packs or other preservatives, yields results consistent with published microbiome studies performed with frozen or otherwise preserved samples. IMPORTANCE In many microbiome studies, the necessity to store samples at room temperature (i.e., remote fieldwork) and the ability to ship samples without hazardous materials that require special handling training, such as ethanol (i.e., citizen science efforts), is paramount. However, although room-temperature storage for a few days has been shown not to obscure physiologically relevant microbiome differences between comparison groups, there are still changes in specific bacterial taxa, notably, in members of the class Gammaproteobacteria, that can make microbiome profiles difficult to interpret. Here we identify the most problematic taxa and show that removing sequences from just a few fast-growing taxa is sufficient to correct microbiome profiles. PMID:28289733

  2. Is it possible to sanitize athletes' shoes?

    PubMed

    Messina, Gabriele; Burgassi, Sandra; Russo, Carmela; Ceriale, Emma; Quercioli, Cecilia; Meniconi, Cosetta

    2015-02-01

    Footwear should be designed to avoid trauma and injury to the skin of the feet that can favor bacterial and fungal infections. Procedures and substances for sanitizing the interior of shoes are uncommon but are important aspects of primary prevention against foot infections and unpleasant odor. To evaluate the efficacy of a sanitizing technique for reducing bacterial and fungal contamination of footwear. Crossover study. Mens Sana basketball team. Twenty-seven male athletes and 4 coaches (62 shoes). The experimental protocol required a first sample (swab), 1/shoe, at time 0 from inside the shoes of all athletes before the sanitizing technique began and a second sample at time 1, after about 4 weeks, April 2012 to May 2012, of daily use of the sanitizing technique. The differences before and after use of the sanitizing technique for total bacterial count at 36 °C and 22 °C for Staphylococcus spp, yeasts, molds, Enterococcus spp, Pseudomonas spp, Escherichia coli , and total coliform bacteria were evaluated. Before use of the sanitizing technique, the total bacterial counts at 36 °C and 22 °C and for Staphylococcus spp were greater by a factor of 5.8 (95% confidence interval [CI] = 3.42, 9.84), 5.84 (95% CI = 3.45, 9.78), and 4.78 (95% CI = 2.84, 8.03), respectively. All the other comparisons showed a reduction in microbial loads, whereas E coli and coliforms were no longer detected. No statistically significant decrease in yeasts (P = .0841) or molds (P = .6913) was recorded probably because of low contamination. The sanitizing technique significantly reduced the bacterial presence in athletes' shoes.

  3. Applications of Mass Spectrometry Imaging for Safety Evaluation.

    PubMed

    Bonnel, David; Stauber, Jonathan

    2017-01-01

    Mass spectrometry imaging (MSI) was first derived from techniques used in physics, which were then incorporated into chemistry followed by application in biology. Developed over 50 years ago, and with different principles to detect and map compounds on a sample surface, MSI supports modern biology questions by detecting biological compounds within tissue sections. MALDI (matrix-assisted laser desorption/ionization) imaging trend analysis in this field shows an important increase in the number of publications since 2005, especially with the development of the MALDI imaging technique and its applications in biomarker discovery and drug distribution. With recent improvements of statistical tools, absolute and relative quantification protocols, as well as quality and reproducibility evaluations, MALDI imaging has become one of the most reliable MSI techniques to support drug discovery and development phases. MSI allows to potentially address important questions in drug development such as "What is the localization of the drug and its metabolites in the tissues?", "What is the pharmacological effect of the drug in this particular region of interest?", or "Is the drug and its metabolites related to an atypical finding?" However, prior to addressing these questions using MSI techniques, expertise needs to be developed to become proficient at histological procedures (tissue preparation with frozen of fixed tissues), analytical chemistry, matrix application, instrumentation, informatics, and mathematics for data analysis and interpretation.

  4. Detection and distribution analysis of organosilicon compounds in wood by means of SEM-EDX and micro-CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vetter, L. de; Cnudde, V.; Masschaele, B.

    This article explores the potential of a scanning electron microscope with an energy dispersive X-ray spectrometer in combination with a new non-destructive 3D visualization technique, X-ray micro-computed tomography, as detection methods for siloxanes/silanes mixtures applied as wood preservatives. In order to have a higher contrast, bromine functional silane was added to the mixture. Scots pine and beech samples were dipped or impregnated with the mixture and subsequently scanned. Both silicon and bromine were easily detectable with both techniques. Dipped siloxanes/silanes covered the cell walls partly in beech and the lumen partly or completely in Scots pine. Impregnated siloxanes/silanes could bemore » found in the cell walls of both wood species. From the results, it can be concluded that, under the circumstances as described in the article, impregnation with a siloxane is necessary to have cell wall penetration. The combination of scanning electron microscopy, energy dispersive X-ray spectroscopy and micro-computed tomography can offer important information concerning the localization of certain products inside wood. While the last of these can monitor changes in 3D, the other two techniques can provide detailed 2D information. Both techniques are complementary and provide important extra information.« less

  5. Comparison of efficacy of pulverization and sterile paper point techniques for sampling root canals.

    PubMed

    Tran, Kenny T; Torabinejad, Mahmoud; Shabahang, Shahrokh; Retamozo, Bonnie; Aprecio, Raydolfo M; Chen, Jung-Wei

    2013-08-01

    The purpose of this study was to compare the efficacy of the pulverization and sterile paper point techniques for sampling root canals using 5.25% NaOCl/17% EDTA and 1.3% NaOCl/MTAD (Dentsply, Tulsa, OK) as irrigation regimens. Single-canal extracted human teeth were decoronated and infected with Enterococcus faecalis. Roots were randomly assigned to 2 irrigation regimens: group A with 5.25% NaOCl/17% EDTA (n = 30) and group B with 1.3% NaOCl/MTAD (n = 30). After chemomechanical debridement, bacterial samplings were taken using sterile paper points and pulverized powder of the apical 5 mm root ends. The sterile paper point technique did not show growth in any samples. The pulverization technique showed growth in 24 of the 60 samples. The Fisher exact test showed significant differences between sampling techniques (P < .001). The sterile paper point technique showed no difference between irrigation regimens. However, 17 of the 30 roots in group A and 7 of the 30 roots in group B resulted in growth as detected by pulverization technique. Data showed a significant difference between irrigation regimens (P = .03) in pulverization technique. The pulverization technique was more efficacious in detecting viable bacteria. Furthermore, this technique showed that 1.3% NaOCl/MTAD regimen was more effective in disinfecting root canals. Published by Elsevier Inc.

  6. Stochastic detection of enantiomers.

    PubMed

    Kang, Xiao-Feng; Cheley, Stephen; Guan, Xiyun; Bayley, Hagan

    2006-08-23

    The rapid quantification of the enantiomers of small chiral molecules is very important, notably in pharmacology. Here, we show that the enantiomers of drug molecules can be distinguished by stochastic sensing, a single-molecule detection technique. The sensing element is an engineered alpha-hemolysin protein pore, fitted with a beta-cyclodextrin adapter. By using the approach, the enantiomeric composition of samples of ibuprofen and thalidomide can be determined in less than 1 s.

  7. Near-infrared Raman spectroscopy to detect anti-Toxoplasma gondii antibodies in blood sera of domestic cats

    NASA Astrophysics Data System (ADS)

    Duarte, Janaina; Pacheco, Marcos T. T.; Silveira, Landulfo, Jr.; Machado, Rosangela Z.; Martins, Rodrigo A. L.; Zangaro, Renato A.; Villaverde, Antonio G. J. B.

    2001-05-01

    Near-infrared (NIR) Raman spectroscopy has been studied for the last years for many biomedical applications. It is a powerful tool for biological materials analysis. Toxoplasmosis is an important zoonosis in public health, cats being the principal responsible for the transmission of the disease in Brazil. The objective of this work is to investigate a new method of diagnosis of this disease. NIR Raman spectroscopy was used to detect anti Toxoplasma gondii antibodies in blood sera from domestic cats, without sample preparation. In all, six blood serum samples were used for this study. A previous serological test was done by the Indirect Immunoenzymatic Assay (ELISA) to permit a comparative study between both techniques and it showed that three serum samples were positive and the other three were negative to toxoplasmosis. Raman spectra were taken for all the samples and analyzed by using the principal components analysis (PCA). A diagnosis parameter was defined from the analysis of the second and third principal components of the Raman spectra. It was found that this parameter can detect the infection level of the animal. The results have indicated that NIR Raman spectroscopy, associated to the PCA can be a promising technique for serological analysis, such as toxoplasmosis, allowing a fast and sensitive method of diagnosis.

  8. Laboratory-based x-ray phase-contrast tomography enables 3D virtual histology

    NASA Astrophysics Data System (ADS)

    Töpperwien, Mareike; Krenkel, Martin; Quade, Felix; Salditt, Tim

    2016-09-01

    Due to the large penetration depth and small wavelength hard x-rays offer a unique potential for 3D biomedical and biological imaging, combining capabilities of high resolution and large sample volume. However, in classical absorption-based computed tomography, soft tissue only shows a weak contrast, limiting the actual resolution. With the advent of phase-contrast methods, the much stronger phase shift induced by the sample can now be exploited. For high resolution, free space propagation behind the sample is particularly well suited to make the phase shift visible. Contrast formation is based on the self-interference of the transmitted beam, resulting in object-induced intensity modulations in the detector plane. As this method requires a sufficiently high degree of spatial coherence, it was since long perceived as a synchrotron-based imaging technique. In this contribution we show that by combination of high brightness liquid-metal jet microfocus sources and suitable sample preparation techniques, as well as optimized geometry, detection and phase retrieval, excellent three-dimensional image quality can be obtained, revealing the anatomy of a cobweb spider in high detail. This opens up new opportunities for 3D virtual histology of small organisms. Importantly, the image quality is finally augmented to a level accessible to automatic 3D segmentation.

  9. Measurement of isotope ratios on transient signals by MC-ICP-MS.

    PubMed

    Günther-Leopold, Ines; Wernli, Beat; Kopajtic, Zlatko; Günther, Detlef

    2004-01-01

    Precise and accurate isotope ratio measurements are an important task in many applications such as isotope-dilution mass spectrometry, bioavailability studies, or the determination of isotope variations in geological or nuclear samples. The technique of MC-ICP-MS has attracted much attention because it permits the precise measurement of isotope compositions for a wide range of elements combined with excellent detection limits due to high ionisation efficiencies. However, the results are based mainly on measurements using continuous sample introduction. In the present study the determination of isotope ratios on various transient signals with a time duration of 30 to 60 s has been achieved by coupling high-performance liquid chromatography to a multicollector inductively coupled plasma mass spectrometer. In order to investigate the origin of ratio drifts across the transient signals for this hyphenated technique, measurements with the same standard solutions were also carried out using a flow-injection device for sample introduction. As a result of this application it could be concluded that the main source of the bias in the measured isotope ratios is within the ICP-MS instead of fractionation effects on the chromatographic column material. Preliminary studies on short transient signals of gaseous samples (dry plasma) showed a reverse fractionation effect compared with wet plasma conditions (flow injection and HPLC).

  10. Detection probability in aerial surveys of feral horses

    USGS Publications Warehouse

    Ransom, Jason I.

    2011-01-01

    Observation bias pervades data collected during aerial surveys of large animals, and although some sources can be mitigated with informed planning, others must be addressed using valid sampling techniques that carefully model detection probability. Nonetheless, aerial surveys are frequently employed to count large mammals without applying such methods to account for heterogeneity in visibility of animal groups on the landscape. This often leaves managers and interest groups at odds over decisions that are not adequately informed. I analyzed detection of feral horse (Equus caballus) groups by dual independent observers from 24 fixed-wing and 16 helicopter flights using mixed-effect logistic regression models to investigate potential sources of observation bias. I accounted for observer skill, population location, and aircraft type in the model structure and analyzed the effects of group size, sun effect (position related to observer), vegetation type, topography, cloud cover, percent snow cover, and observer fatigue on detection of horse groups. The most important model-averaged effects for both fixed-wing and helicopter surveys included group size (fixed-wing: odds ratio = 0.891, 95% CI = 0.850–0.935; helicopter: odds ratio = 0.640, 95% CI = 0.587–0.698) and sun effect (fixed-wing: odds ratio = 0.632, 95% CI = 0.350–1.141; helicopter: odds ratio = 0.194, 95% CI = 0.080–0.470). Observer fatigue was also an important effect in the best model for helicopter surveys, with detection probability declining after 3 hr of survey time (odds ratio = 0.278, 95% CI = 0.144–0.537). Biases arising from sun effect and observer fatigue can be mitigated by pre-flight survey design. Other sources of bias, such as those arising from group size, topography, and vegetation can only be addressed by employing valid sampling techniques such as double sampling, mark–resight (batch-marked animals), mark–recapture (uniquely marked and identifiable animals), sightability bias correction models, and line transect distance sampling; however, some of these techniques may still only partially correct for negative observation biases.

  11. Rapid Discrimination for Traditional Complex Herbal Medicines from Different Parts, Collection Time, and Origins Using High-Performance Liquid Chromatography and Near-Infrared Spectral Fingerprints with Aid of Pattern Recognition Methods

    PubMed Central

    Fu, Haiyan; Fan, Yao; Zhang, Xu; Lan, Hanyue; Yang, Tianming; Shao, Mei; Li, Sihan

    2015-01-01

    As an effective method, the fingerprint technique, which emphasized the whole compositions of samples, has already been used in various fields, especially in identifying and assessing the quality of herbal medicines. High-performance liquid chromatography (HPLC) and near-infrared (NIR), with their unique characteristics of reliability, versatility, precision, and simple measurement, played an important role among all the fingerprint techniques. In this paper, a supervised pattern recognition method based on PLSDA algorithm by HPLC and NIR has been established to identify the information of Hibiscus mutabilis L. and Berberidis radix, two common kinds of herbal medicines. By comparing component analysis (PCA), linear discriminant analysis (LDA), and particularly partial least squares discriminant analysis (PLSDA) with different fingerprint preprocessing of NIR spectra variables, PLSDA model showed perfect functions on the analysis of samples as well as chromatograms. Most important, this pattern recognition method by HPLC and NIR can be used to identify different collection parts, collection time, and different origins or various species belonging to the same genera of herbal medicines which proved to be a promising approach for the identification of complex information of herbal medicines. PMID:26345990

  12. Environmental radioactivity measurements and applications - Difficulties, current status and future trends

    NASA Astrophysics Data System (ADS)

    Anagnostakis, Marios J.

    2015-11-01

    For several decades natural and artificial radioactivity in the environment have been extensively studied all around the world. Nuclear accidents - mainly that of Chernobyl - have led to the development of the field of radioecology, while detector systems and techniques - with predominant that of γ-spectrometry - have been continuously developed through the years to meet researchers' needs. The study of natural radionuclides that was originally limited to 226Ra, 232Th and 40K was then extended to include radionuclides such as 234Th, 210Pb, 235U and 7Be, which allowed the study of radioactive equilibrium. Besides their importance from the radiation protection point of view, many radionuclides are also used as tracers of environmental processes, such as aerosol and transportation of air masses studies (7Be, 10Be, 22Na), soil erosion, sedimentation and geochronology (210Pb, 137Cs), marine ecosystems studies and studies related to climate change. All these studies require specialized samplings strategies and sampling preparation techniques as well as high quality measurements, while the improvement of detection limits is often of vital importance. This work is a review of environmental radioactivity measurements and applications, mainly focused in the field of γ-spectrometry, for which difficulties and limitations will be presented, together with future trends, new challenges and applications.

  13. Solvent viscosity mismatch between the solute plug and the mobile phase: Considerations in the applications of two-dimensional HPLC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shalliker, R. Andrew; Guiochon, Georges A

    Understanding the nature of viscosity contrast induced flow instabilities is an important aspect in the design of two-dimensional HPLC separations. When the viscosity contrast between the sample plug and the mobile phase is sufficiently large, the phenomenon known as viscous fingering can be induced. Viscous fingering is a flow instability phenomenon that occurs at the interface between two fluids with different viscosities. In liquid chromatography, viscous fingering results in the solute band undergoing a change in form as it enters into the chromatography column. Moreover, even in the absence of viscous fingering, band shapes change shape at low viscosity contrasts.more » These changes can result in a noticeable change in separation performance, with the result depending on whether the solvent pushing the solute plug has a higher or lower viscosity than the solute plug. These viscosity induced changes become more important as the solute injection volume increases and hence understanding the process becomes critical in the implementation of multidimensional HPLC techniques, since in these techniques the sample injection plug into the second dimension is an order of magnitude greater than in one-dimensional HPLC. This review article assesses the current understanding of the viscosity contrast induced processes as they relate to liquid chromatographic separation behaviour.« less

  14. Proteomic Challenges: Sample Preparation Techniques for Microgram-Quantity Protein Analysis from Biological Samples

    PubMed Central

    Feist, Peter; Hummon, Amanda B.

    2015-01-01

    Proteins regulate many cellular functions and analyzing the presence and abundance of proteins in biological samples are central focuses in proteomics. The discovery and validation of biomarkers, pathways, and drug targets for various diseases can be accomplished using mass spectrometry-based proteomics. However, with mass-limited samples like tumor biopsies, it can be challenging to obtain sufficient amounts of proteins to generate high-quality mass spectrometric data. Techniques developed for macroscale quantities recover sufficient amounts of protein from milligram quantities of starting material, but sample losses become crippling with these techniques when only microgram amounts of material are available. To combat this challenge, proteomicists have developed micro-scale techniques that are compatible with decreased sample size (100 μg or lower) and still enable excellent proteome coverage. Extraction, contaminant removal, protein quantitation, and sample handling techniques for the microgram protein range are reviewed here, with an emphasis on liquid chromatography and bottom-up mass spectrometry-compatible techniques. Also, a range of biological specimens, including mammalian tissues and model cell culture systems, are discussed. PMID:25664860

  15. Application of artificial neural networks for conformity analysis of fuel performed with an optical fiber sensor

    NASA Astrophysics Data System (ADS)

    Possetti, Gustavo Rafael Collere; Coradin, Francelli Klemba; Côcco, Lílian Cristina; Yamamoto, Carlos Itsuo; de Arruda, Lucia Valéria Ramos; Falate, Rosane; Muller, Marcia; Fabris, José Luís

    2008-04-01

    The liquid fuel quality control is an important issue that brings benefits for the State, for the consumers and for the environment. The conformity analysis, in special for gasoline, demands a rigorous sampling technique among gas stations and other economic agencies, followed by a series of standard physicochemical tests. Such procedures are commonly expensive and time demanding and, moreover, a specialist is often required to carry out the tasks. Such drawbacks make the development of alternative analysis tools an important research field. The fuel refractive index is an additional parameter to help the fuel conformity analysis, besides the prospective optical fiber sensors, which operate like transducers with singular properties. When this parameter is correlated with the sample density, it becomes possible to determine conformity zones that cannot be analytically defined. This work presents an application of artificial neural networks based on Radial Basis Function to determine these zones. A set of 45 gasoline samples, collected in several gas stations and previously analyzed according to the rules of Agência Nacional do Petróleo, Gás Natural e Biocombustíveis, a Brazilian regulatory agency, constituted the database to build two neural networks. The input variables of first network are the samples refractive indices, measured with an Abbe refractometer, and the density of the samples measured with a digital densimeter. For the second network the input variables included, besides the samples densities, the wavelength response of a long-period grating to the samples refractive indices. The used grating was written in an optical fiber using the point-to-point technique by submitting the fiber to consecutive electrical arcs from a splice machine. The output variables of both Radial Basis Function Networks are represented by the conformity status of each sample, according to report of tests carried out following the American Society for Testing and Materials and/or Brazilian Association of Technical Rules standards. A subset of 35 samples, randomly chosen from the database, was used to design and calibrate (train) both networks. The two networks topologies (numbers of Radial Basis Function neurons of the hidden layer and function radius) were built in order to minimize the root mean square error. The subset composed by the other 10 samples was used to validate the final networks architectures. The obtained results have demonstrated that both networks reach a good predictive capability.

  16. Technical note: Alternatives to reduce adipose tissue sampling bias.

    PubMed

    Cruz, G D; Wang, Y; Fadel, J G

    2014-10-01

    Understanding the mechanisms by which nutritional and pharmaceutical factors can manipulate adipose tissue growth and development in production animals has direct and indirect effects in the profitability of an enterprise. Adipocyte cellularity (number and size) is a key biological response that is commonly measured in animal science research. The variability and sampling of adipocyte cellularity within a muscle has been addressed in previous studies, but no attempt to critically investigate these issues has been proposed in the literature. The present study evaluated 2 sampling techniques (random and systematic) in an attempt to minimize sampling bias and to determine the minimum number of samples from 1 to 15 needed to represent the overall adipose tissue in the muscle. Both sampling procedures were applied on adipose tissue samples dissected from 30 longissimus muscles from cattle finished either on grass or grain. Briefly, adipose tissue samples were fixed with osmium tetroxide, and size and number of adipocytes were determined by a Coulter Counter. These results were then fit in a finite mixture model to obtain distribution parameters of each sample. To evaluate the benefits of increasing number of samples and the advantage of the new sampling technique, the concept of acceptance ratio was used; simply stated, the higher the acceptance ratio, the better the representation of the overall population. As expected, a great improvement on the estimation of the overall adipocyte cellularity parameters was observed using both sampling techniques when sample size number increased from 1 to 15 samples, considering both techniques' acceptance ratio increased from approximately 3 to 25%. When comparing sampling techniques, the systematic procedure slightly improved parameters estimation. The results suggest that more detailed research using other sampling techniques may provide better estimates for minimum sampling.

  17. Comparison of destructive and nondestructive sampling techniques of retail chicken carcasses for enumeration of hygiene indicator microorganisms.

    PubMed

    Cossi, Marcus Vinícius Coutinho; de Almeida, Michelle Vieira; Dias, Mariane Rezende; de Arruda Pinto, Paulo Sérgiode; Nero, Luís Augusto

    2012-01-01

    The type of sampling technique used to obtain food samples is fundamental to the success of microbiological analysis. Destructive and nondestructive techniques, such as tissue excision and rinsing, respectively, are widely employed in obtaining samples from chicken carcasses. In this study, four sampling techniques used for chicken carcasses were compared to evaluate their performances in the enumeration of hygiene indicator microorganisms. Sixty fresh chicken carcasses were sampled by rinsing, tissue excision, superficial swabbing, and skin excision. All samples were submitted for enumeration of mesophilic aerobes, Enterobacteriaceae, coliforms, and Escherichia coli. The results were compared to determine the statistical significance of differences and correlation (P < 0.05). Tissue excision provided the highest microbial counts compared with the other procedures, with significant differences obtained only for coliforms and E. coli (P < 0.05). Significant correlations (P < 0.05) were observed for all the sampling techniques evaluated for most of the hygiene indicators. Despite presenting a higher recovery ability, tissue excision did not present significant differences for microorganism enumeration compared with other nondestructive techniques, such as rinsing, indicating its adequacy for microbiological analysis of chicken carcasses.

  18. An advanced uracil DNA glycosylase-supplemented loop-mediated isothermal amplification (UDG-LAMP) technique used in the sensitive and specific detection of Cryptosporidium parvum, Cryptosporidium hominis, and Cryptosporidium meleagridis in AIDS patients.

    PubMed

    Fallahi, Shirzad; Moosavi, Seyedeh Fatemeh; Karimi, Azadeh; Chegeni, Ali Sharafi; Saki, Mohammad; Namdari, Parsa; Rashno, Mohammad Menati; Varzi, Ali Mohamad; Tarrahi, Mohammad Javad; Almasian, Mohammad

    2018-05-01

    The rapid and accurate detection of Cryptosporidium spp. is critically important for the prevention and timely treatment of cryptosporidiosis in AIDS patients (APs). This study was conducted to examine a UDG-LAMP technique for the first time to diagnose cryptosporidiosis in APs. After collecting demographic and clinical data, three stool samples were collected from the participants (120 volunteering APs). The microscopic examination of stained smears using the acid-fast method and the UDG-LAMP assay were performed for each sample. 10% of APs were infected with Cryptosporidium spp. The number of detected cryptosporidiosis cases using the acid-fast staining and UDG-LAMP methods were significantly different (P < 0.001). Diarrhea and weight loss were found to be significantly associated with cryptosporidiosis in patients (P < 0.05). The pretreatment of LAMP reagents with UDG successfully eliminated the likelihood of product re-amplification remaining from previous reactions. The UDG-LAMP technique could detect cryptosporidiosis in APs with high sensitivity and rapidity without carryover contamination. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Application of Principal Component Analysis to NIR Spectra of Phyllosilicates: A Technique for Identifying Phyllosilicates on Mars

    NASA Technical Reports Server (NTRS)

    Rampe, E. B.; Lanza, N. L.

    2012-01-01

    Orbital near-infrared (NIR) reflectance spectra of the martian surface from the OMEGA and CRISM instruments have identified a variety of phyllosilicates in Noachian terrains. The types of phyllosilicates present on Mars have important implications for the aqueous environments in which they formed, and, thus, for recognizing locales that may have been habitable. Current identifications of phyllosilicates from martian NIR data are based on the positions of spectral absorptions relative to laboratory data of well-characterized samples and from spectral ratios; however, some phyllosilicates can be difficult to distinguish from one another with these methods (i.e. illite vs. muscovite). Here we employ a multivariate statistical technique, principal component analysis (PCA), to differentiate between spectrally similar phyllosilicate minerals. PCA is commonly used in a variety of industries (pharmaceutical, agricultural, viticultural) to discriminate between samples. Previous work using PCA to analyze raw NIR reflectance data from mineral mixtures has shown that this is a viable technique for identifying mineral types, abundances, and particle sizes. Here, we evaluate PCA of second-derivative NIR reflectance data as a method for classifying phyllosilicates and test whether this method can be used to identify phyllosilicates on Mars.

  20. Modern separation techniques coupled to high performance mass spectrometry for glycolipid analysis.

    PubMed

    Sarbu, Mirela; Zamfir, Alina Diana

    2018-01-21

    Glycolipids (GLs), involved in biological processes and pathologies, such as viral, neurodegenerative and oncogenic transformations are in the focus of research related to method development for structural analysis. This review highlights modern separation techniques coupled to mass spectrometry (MS) for the investigation of GLs from various biological matrices. First section is dedicated to methods, which, although provide the separation in a non-liquid phase, are able to supply important data on the composition of complex mixtures. While classical thin layer chromatography (TLC) is useful for MS analyses of the fractionated samples, ultramodern ion mobility (IMS) characterized by high reproducibility facilitates to discover minor species and to apply low sample amounts, in addition to providing conformational separation with isomer discrimination. Second section highlights the advantages, applications and limitations of liquid-based separation techniques such as high performance liquid chromatography (HPLC) and hydrophilic interaction liquid chromatography (HILIC) in direct or indirect coupling to MS for glycolipidomics surveys. The on- and off-line capillary electrophoresis (CE) MS, offering a remarkable separation efficiency of GLs is also presented and critically assessed from the technical and application perspective in the final part of the review. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Top